Sample records for evaluating home heating

  1. Mind the gap - Deriving a compatible user mental model of the home heating system to encourage sustainable behaviour.

    PubMed

    Revell, Kirsten M A; Stanton, Neville A

    2016-11-01

    Householders' behaviour with their home heating systems is a considerable contributor to domestic energy consumption. To create a design specification for the 'scaffolding' needed for sustainable behaviour with home heating controls, Norman's (1986) Gulf of Execution and Evaluation was applied to the home heating system. A Home Heating Design Model (DM) was produced with a home heating expert. Norman's (1986) 7 Stages of Activity were considered to derive a Compatible User Mental Model (CUMM) of a typical Heating System. Considerable variation in the concepts needed at each stage was found. Elements that could be derived from the DM supported stages relating to action specification, execution, perception and interpretation, but many are not communicated in the design of typical heating controls. Stages relating to goals, intentions and evaluation required concepts beyond the DM. A systems view that tackles design for sustainable behaviour from a variety of levels is needed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Ductless Mini-Split Heat Pump Comfort Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roth, K.; Sehgal, N.; Akers, C.

    2013-03-01

    Field tests were conducted in two homes in Austin, TX, to evaluate the comfort performance of ductless minisplit heat pumps (DMSHPs), measuring temperature and relative humidity measurements in four rooms in each home before and after retrofitting a central HVAC system with DMSHPs.

  3. Ductless Mini-Split Heat Pump Comfort Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roth, K.; Sehgal, N.; Akers, C.

    2013-03-01

    Field tests were conducted in two homes in Austin, TX to evaluate the comfort performance of ductless mini-split heat pumps (DMSHPs), measuring temperature and relative humidity measurements in four rooms in each home before and after retrofitting a central HVAC system with DMSHPs.

  4. Evaluating Moisture Control of Variable-Capacity Heat Pumps in Mechanically Ventilated, Low-Load Homes in Climate Zone 2A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, Eric; Withers, Chuck; McIlvaine, Janet

    Low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. This report evaluates the performance of variable-capacity comfort systems, with a focus on inverter-driven, variable-capacity systems, as well as proposed system enhancements.

  5. Using the Earth to Heat and Cool Homes.

    ERIC Educational Resources Information Center

    Thomas, Stephen G.

    The heat collecting capacity of the earth and or the earth's ground waters and surface waters exist as potential energy sources for home heating and cooling. Techniques and devices associated with use of the earth's thermal energy capabilities are presented and evaluated in this four-chapter report. Included in these chapters are: (1) descriptions…

  6. Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Backman, C.; German, A.; Dakin, B.

    2013-12-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 tomore » test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).« less

  7. Field Evaluation of Highly Insulating Windows in the Lab Homes: Winter Experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, Graham B.; Widder, Sarah H.; Bauman, Nathan N.

    2012-06-01

    This field evaluation of highly insulating windows was undertaken in a matched pair of 'Lab Homes' located on the Pacific Northwest National Laboratory (PNNL) campus during the 2012 winter heating season. Improving the insulation and solar heat gain characteristics of a home's windows has the potential to significantly improve the home's building envelope and overall thermal performance by reducing heat loss (in the winter), and cooling loss and solar heat gain (in the summer) through the windows. A high quality installation and/or window retrofit will also minimize or reduce air leakage through the window cavity and thus also contribute tomore » reduced heat loss in the winter and cooling loss in the summer. These improvements all contribute to decreasing overall annual home energy use. Occupant comfort (non-quantifiable) can also be increased by minimizing or eliminating the cold 'draft' (temperature) many residents experience at or near window surfaces that are at a noticeably lower temperature than the room air temperature. Lastly, although not measured in this experiment, highly insulating windows (triple-pane in this experiment) also have the potential to significantly reduce the noise transmittance through windows compared to standard double-pane windows. The metered data taken in the Lab Homes and data analysis presented here represent 70 days of data taken during the 2012 heating season. As such, the savings from highly insulating windows in the experimental home (Lab Home B) compared to the standard double-pane clear glass windows in the baseline home (Lab Home A) are only a portion of the energy savings expected from a year-long experiment that would include a cooling season. The cooling season experiment will take place in the homes in the summer of 2012, and results of that experiment will be reported in a subsequent report available to all stakeholders.« less

  8. Super Energy Efficiency Design (S.E.E.D.) Home Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    German, A.; Dakin, B.; Backman, C.

    This report describes the results of evaluation by the Alliance for Residential Building Innovation (ARBI) Building America team of the 'Super Energy Efficient Design' (S.E.E.D) home, a 1,935 sq. ft., single-story spec home located in Tucson, AZ. This prototype design was developed with the goal of providing an exceptionally energy efficient yet affordable home and includes numerous aggressive energy features intended to significantly reduce heating and cooling loads such as structural insulated panel (SIP) walls and roof, high performance windows, an ERV, an air-to-water heat pump with mixed-mode radiant and forced air delivery, solar water heating, and rooftop PV. Sourcemore » energy savings are estimated at 45% over the Building America B10 Benchmark. System commissioning, short term testing, long term monitoring and detailed analysis of results was conducted to identify the performance attributes and cost effectiveness of the whole house measure package.« less

  9. Super Energy Efficient Design (S.E.E.D.) Home Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    German, A.; Dakin, B.; Backman, C.

    This report describes the results of evaluation by the Alliance for Residential Building Innovation (ARBI) Building America team of the “Super Energy Efficient Design” (S.E.E.D) home, a 1,935 sq. ft., single-story spec home located in Tucson, AZ. This prototype design was developed with the goal of providing an exceptionally energy efficient yet affordable home and includes numerous aggressive energy features intended to significantly reduce heating and cooling loads such as structural insulated panel (SIP) walls and roof, high performance windows, an ERV, an air-to-water heat pump with mixed-mode radiant and forced air delivery, solar water heating, and rooftop PV. Sourcemore » energy savings are estimated at 45% over the Building America B10 Benchmark. System commissioning, short term testing, long term monitoring and detailed analysis of results was conducted to identify the performance attributes and cost effectiveness of the whole house measure package.« less

  10. Evaluation of Retrofit Variable-Speed Furnace Fan Motors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aldrich, R.; Williamson, J.

    2014-01-01

    In conjunction with the New York State Energy Research and Development Authority (NYSERDA) and Proctor Engineering Group, Ltd. (PEG), the Consortium for Advanced Residential Buildings (CARB) has evaluated the Concept 3 (tm) replacement motors for residential furnaces. These brushless, permanent magnet (BPM) motors can use much less electricity than their PSC (permanent split capacitor) predecessors. This evaluation focuses on existing homes in the heating-dominated climate of upstate New York with the goals of characterizing field performance and cost-effectiveness. The results of this study are intended to be useful to home performance contractors, HVAC contractors, and home efficiency program stakeholders. Themore » project includes eight homes in and near Syracuse, NY. Tests and monitoring was performed both before and after fan motors were replaced. Average fan power reductions were approximately 126 Watts during heating and 220 Watts during cooling operation. Over the course of entire heating and cooling seasons, these translated into average electric energy savings of 163 kWh. Average cost savings were $20 per year. Homes where the fan was used outside of heating and cooling mode saved an additional $42 per year on average. Results indicate that BPM replacement motors will be most cost-effective in HVAC systems with longer run times and relatively low duct static pressures. More dramatic savings are possible if occupants use the fan-only setting when there is no thermal load. There are millions of cold-climate, U.S. homes that meet these criteria, but the savings in most homes tested in this study were modest.« less

  11. Passive cigarette smoke, coal heating, and respiratory symptoms of nonsmoking women in China

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pope, C.A. III; Xu, X.

    1993-09-01

    In this study the authors evaluated data from a sample of 973 never-smoking women, ages 20-40, who worked in three similar textile mills in Anhui Province, China. They compared prevalence rates of respiratory symptoms across homes with and without coal heating and homes with different numbers of smokers. Multiple logistic regression models that controlled for age, job title, and mill of employment were also estimated. Respiratory symptoms were associated with combined exposure to passive cigarette smoke and coal heating. Effects of passive cigarette smoke and coal heating on respiratory symptoms appeared to be nearly additive, suggesting a dose-response relationship betweenmore » respiratory symptoms and home indoor air pollution from these two sources. The prevalence of chest illness, cough, phlegm, and shortness of breath (but not wheeze) was significantly elevated for women living in homes with both smokers and coal heating.« less

  12. Climate change and health: Indoor heat exposure in vulnerable populations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White-Newsome, Jalonne L., E-mail: jalonne@umich.edu; Sanchez, Brisa N., E-mail: brisa@umich.edu; Jolliet, Olivier, E-mail: ojolliet@umich.edu

    2012-01-15

    Introduction: Climate change is increasing the frequency of heat waves and hot weather in many urban environments. Older people are more vulnerable to heat exposure but spend most of their time indoors. Few published studies have addressed indoor heat exposure in residences occupied by an elderly population. The purpose of this study is to explore the relationship between outdoor and indoor temperatures in homes occupied by the elderly and determine other predictors of indoor temperature. Materials and methods: We collected hourly indoor temperature measurements of 30 different homes; outdoor temperature, dewpoint temperature, and solar radiation data during summer 2009 inmore » Detroit, MI. We used mixed linear regression to model indoor temperatures' responsiveness to weather, housing and environmental characteristics, and evaluated our ability to predict indoor heat exposures based on outdoor conditions. Results: Average maximum indoor temperature for all locations was 34.85 Degree-Sign C, 13.8 Degree-Sign C higher than average maximum outdoor temperature. Indoor temperatures of single family homes constructed of vinyl paneling or wood siding were more sensitive than brick homes to outdoor temperature changes and internal heat gains. Outdoor temperature, solar radiation, and dewpoint temperature predicted 38% of the variability of indoor temperatures. Conclusions: Indoor exposures to heat in Detroit exceed the comfort range among elderly occupants, and can be predicted using outdoor temperatures, characteristics of the housing stock and surroundings to improve heat exposure assessment for epidemiological investigations. Weatherizing homes and modifying home surroundings could mitigate indoor heat exposure among the elderly.« less

  13. Evaluation of field methods for estimating exposure of children in low-income families to polycyclic aromatic hydrocarbons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, N.K.; Chuang, J.C.; Lyu, C.

    1996-12-31

    Children in low-income families may have higher exposures to polycyclic aromatic hydrocarbons (PAH) and related compounds than children in higher-income families. These higher exposures could result from the location of their homes, nearer to industrial sites and traffic; from poorer diet; from environmental tobacco smoke; or other causes. The study was designed to evaluate methods and estimate the range of total exposures of low-income children to PAH through various pathways. Nonsmoking participants with preschool children, incomes at or below the official US poverty level, and space heating in their homes were recruited. The PAH concentrations were measured in the householdmore » indoor and outdoor air, house dust, and yard soil, and in the diet of both an adult and a preschool child living in the home. An initial study in two homes and an additional study of nine homes, four urban and five rural, during the heating season were completed. The problems and successes encountered in the recruitment process and selected results of the heating season measurements are summarized in the paper.« less

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Three side-by-side lab houses were built, instrumented and monitored in an effort to determine through field testing and analysis the relative contributions of select technologies toward reducing energy use in new manufactured homes.The lab houses in Russellville, Alabama compared the performance of three homes built to varying levels of thermal integrity and HVAC equipment: a baseline HUD-code home equipped with an electric furnace and a split system air conditioner; an ENERGY STAR manufactured home with an enhanced thermal envelope and traditional split system heat pump; and a house designed to qualify for Zero Energy Ready Home designation with a ductlessmore » mini-split heat pump with transfer fan distribution system in place of the traditional duct system for distribution. Experiments were conducted in the lab houses to evaluate impact on energy and comfort of interior door position, window blind position and transfer fan operation. The report describes results of tracer gas and co-heating tests and presents calculation of the heat pump coefficient of performance for both the traditional heat pump and the ductless mini-split. A series of calibrated energy models was developed based on measured data and run in three locations in the Southeast to compare annual energy usage of the three homes.« less

  15. RDI's Wisdom Way Solar Village Final Report: Includes Utility Bill Analysis of Occupied Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robb Aldrich, Steven Winter Associates

    2011-07-01

    In 2010, Rural Development, Inc. (RDI) completed construction of Wisdom Way Solar Village (WWSV), a community of ten duplexes (20 homes) in Greenfield, MA. RDI was committed to very low energy use from the beginning of the design process throughout construction. Key features include: 1. Careful site plan so that all homes have solar access (for active and passive); 2. Cellulose insulation providing R-40 walls, R-50 ceiling, and R-40 floors; 3. Triple-pane windows; 4. Airtight construction (~0.1 CFM50/ft2 enclosure area); 5. Solar water heating systems with tankless, gas, auxiliary heaters; 6. PV systems (2.8 or 3.4kWSTC); 7. 2-4 bedrooms, 1,100-1,700more » ft2. The design heating loads in the homes were so small that each home is heated with a single, sealed-combustion, natural gas room heater. The cost savings from the simple HVAC systems made possible the tremendous investments in the homes' envelopes. The Consortium for Advanced Residential Buildings (CARB) monitored temperatures and comfort in several homes during the winter of 2009-2010. In the Spring of 2011, CARB obtained utility bill information from 13 occupied homes. Because of efficient lights, appliances, and conscientious home occupants, the energy generated by the solar electric systems exceeded the electric energy used in most homes. Most homes, in fact, had a net credit from the electric utility over the course of a year. On the natural gas side, total gas costs averaged $377 per year (for heating, water heating, cooking, and clothes drying). Total energy costs were even less - $337 per year, including all utility fees. The highest annual energy bill for any home evaluated was $458; the lowest was $171.« less

  16. Coal home heating and environmental tobacco smoke in relation to lower respiratory illness in Czech children, from birth to 3 years of age

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, R.J.; Hert-Picciotto, I.; Dostal, M.

    2006-07-15

    The objective of this study was to evaluate how indoor pollution from tobacco and home heating may adversely affect respiratory health in young children. A total of 452 children born 1994-1996 in two districts in the Czech Republic participated. Lower respiratory illness (LRI) diagnoses occurred more frequently in children from homes heated by coal (vs. other energy sources or distant furnaces; rate ratio (RR) = 1.45; 95% confidence interval (CI), 1.07-1.97). Maternal prenatal smoking and other adult smokers also increased LRI rates (respectively: RR = 1.48; 95% CI, 1.10-2.01; and RR = 1.29; 95% CI, 1.01-1.65). Cooking fuels (primarily electricity,more » natural gas, or propane) were not associated with LRI incidence. For children never breast-fed, coal home heating and mother's smoking conferred substantially greater risks: RR = 2.77 (95% CI, 1.45-5.27) and RR = 2.52 (95% CI, 1.31-4.85), respectively. This maternal smoking and coal home heating increased risk for LRI in the first 3 years of life, particularly in children not breast-fed.« less

  17. New Whole-House Solutions Case Study: Testing Ductless Heat Pumps in High-Performance Affordable Housing, the Woods at Golden Given - Tacoma, Washington

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2015-06-01

    The Woods is a 30-home, high- performance, energy efficient sustainable community built by Habitat for Humanity (HFH). With Support from Tacoma Public Utilities, Washington State University (part of the Building America Partnership for Improved Residential Construction) is researching the energy performance of these homes and the ductless heat pumps (DHP) they employ. This project provides Building America with an opportunity to: field test HVAC equipment, ventilation system air flows, building envelope tightness, lighting, appliance, and other input data that are required for preliminary Building Energy Optimization (BEopt™) modeling and ENERGY STAR® field verification; analyze cost data from HFH and othermore » sources related to building-efficiency measures that focus on the DHP/hybrid heating system and heat recovery ventilation system; evaluate the thermal performance and cost benefit of DHP/hybrid heating systems in these homes from the perspective of homeowners; compare the space heating energy consumption of a DHP/electric resistance (ER) hybrid heating system to that of a traditional zonal ER heating system; conduct weekly "flip-flop tests" to compare space heating, temperature, and relative humidity in ER zonal heating mode to DHP/ER mode.« less

  18. Evaluating Moisture Control of Variable-Capacity Heat Pumps in Mechanically Ventilated, Low-Load Homes in Climate Zone 2A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, Eric; Withers, Chuck; McIlvaine, Janet

    The well-sealed, highly insulated building enclosures constructed by today's home building industry coupled with efficient lighting and appliances are achieving significantly reduced heating and cooling loads. These low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. Even if fixed-capacity equipment can be properly specified for peak loads, it remains oversized for use during much of the year. During these part-load cooling hours, oversized equipment meets the target dry-bulb temperatures very quickly, often without sufficient opportunity for moisture control. Themore » problem becomes more acute for high-performance houses in humid climates when meeting ASHRAE Standard 62.2 recommendations for wholehouse mechanical ventilation.« less

  19. Greenbelt Homes Pilot Program. Summary of Building Envelope Retrofits, Planned HVAC Equipment Upgrades, and Energy Savings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiehagen, J.; Del Bianco, M.; Mallay, D.

    2015-05-22

    The U.S. Department of Energy Building America team Partnership for Home Innovation wrote a report on Phase 1 of the project that summarized a condition assessment of the homes and evaluated retrofit options within the constraints of the cooperative provided by GHI. Phase 2 was completed following monitoring in the 2013–2014 winter season; the results are summarized in this report. Phase 3 upgrades of heating equipment will be implemented in time for the 2014–2015 heating season and are not part of this report.

  20. New Whole-House Solutions Case Study: Hydronic Heating Coil Versus Propane Furnace, Rehoboth Beach, Delaware

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-01-01

    In this project involving two homes, the IBACOS team evaluated the performance of the two space conditioning systems and the modeled efficiency of the two tankless domestic hot water systems relative to actual occupant use. Each house was built by Insight Homes and is 1,715-ft2 with a single story, three bedrooms, two bathrooms, and the heating, ventilation, and air conditioning systems and ductwork located in conditioned crawlspaces. The standard house, which the builder offers as its standard production house, uses an air source heat pump (ASHP) with supplemental propane furnace heating. The Building America test house uses the same ASHPmore » unit with supplemental heat provided by the DHW heater (a combined DHW and hydronic heating system, where the hydronic heating element is in the air handler).« less

  1. Mini-Split Heat Pump Evaluation and Zero Energy Ready Home Support

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herk, Anastasia

    IBACOS worked with builder Imagine Homes to evaluate the performance of an occupied new construction test house following construction of the house in the hot, humid climate of San Antonio, Texas. The project measures the effectiveness of a space conditioning strategy using a multihead mini-split heat pump (MSHP) system in a reduced-load home to achieve acceptable comfort levels (temperature and humidity) and energy performance. IBACOS collected long-term data and analyzed the energy consumption and comfort conditions of the occupied house after one year of operation. Although measured results indicate that the test system provides comfort both inside and outside themore » ASHRAE Standard 55-2010 range, the occupants of the house claimed both adequate comfort and appreciation of the ease of use and flexibility of the installed MSHP system. IBACOS also assisted the builder to evaluate design and specification changes necessary to comply with Zero Energy Ready Home, but the builder chose to not move forward with it because of concerns about the 'solar ready' requirements of the program.« less

  2. Technology Solutions Case Study: Replacement of Variable-Speed Motors for Furnaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2013-02-01

    In conjunction with the New York State Energy Research and Development Authority (NYSERDA) and Proctor Engineering Group, Ltd. (PEG), the Consortium for Advanced Residential Buildings (CARB) evaluated the Concept 3™ replacement motors for residential furnaces in eight homes in Syracuse, NY. These brushless, permanent magnet (BPM) motors can use much less electricity than their PSC (permanent split capacitor) predecessors. This evaluation focuses on existing homes in the heating-dominated climate of upstate New York with the goals of characterizing field performance and cost-effectiveness. The results of this study are intended to be useful to home performance contractors, HVAC contractors, and homemore » efficiency program stakeholders. Tests and monitoring was performed both before and after fan motors were replaced. Average fan power reductions were approximately 126 Watts during heating and 220 Watts during cooling operation. Over the course of entire heating and cooling seasons, these translated into average electric energy savings of 163 kWh, with average cost savings of $20 per year. Homes where the fan was used outside of heating and cooling mode saved an additional $42 per year on average. Results indicate that BPM replacement motors will be most cost-effective in HVAC systems with longer run times and relatively low duct static pressures. More dramatic savings are possible if occupants use the fan-only setting when there is no thermal load.« less

  3. Phased Retrofits in Existing Homes in Florida Phase II: Shallow Plus Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sutherland, K.; Parker, D.; Martin, E.

    Originally published in February 2016, this revision contains an added section called 'Evaluation of Complete Central System Replacement with Inverter-Driven Heat Pump,' which presents the designs and energy savings evaluations of two different schemes wherein inverter-driven systems replaced a home's existing central system. Analyses for three additional retrofit measures were bolstered by longer-term data; these are described in the sections on supplemental mini-split heat pumps (MSHPs), smart thermostats, and heat pump clothes dryers. The sections on supplemental MSHPs and smart thermostats were also enhanced with larger sample sizes and projections of weather-normalized annual energy savings. Finally, peak system hour energymore » demand-reduction predictions are provided for all retrofit measures where meaningful impacts could be drawn.« less

  4. Mini-Split Heat Pump Evaluation and Zero Energy Ready Home Support

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herk, Anastasia

    This project was created from a partnership between the U.S. Department of Energy’s (DOE’s) Building America research team IBACOS, Inc. and Imagine Homes, a production homebuilder of high-performance homes in San Antonio, Texas—a hot-humid climate. The primary purpose was to evaluate the performance of a multihead mini-split heat pump (MSHP) space-conditioning system, which consists of ducted and ductless indoor units, in maintaining uniform comfort in an occupied test house. The research team evaluated the MSHP space-conditioning strategy for its effectiveness in achieving uniform temperature and relative humidity (RH) levels throughout the test house and for overall constructability and cost. Thismore » evaluation was based on data that were collected from short-term tests and monitoring during 1 year of occupancy, as well as from builder and occupant feedback. Design considerations for integrating an MSHP system into the builder’s full range of production home designs were also explored, with a focus on minimizing the cost and complexity of the system design while meeting the thermal loads of the house and providing occupant comfort according to ANSI/ASHRAE Standard 55-2010 (ASHRAE 2010a).« less

  5. Infant otitis media and the use of secondary heating sources.

    PubMed

    Pettigrew, Melinda M; Gent, Janneane F; Triche, Elizabeth W; Belanger, Kathleen D; Bracken, Michael B; Leaderer, Brian P

    2004-01-01

    This prospective study investigated the association of exposure to indoor secondary heating sources with otitis media and recurrent otitis media risk in infants. We enrolled mothers living in nonsmoking households and delivering babies between 1993 and 1996 in 12 Connecticut and Virginia hospitals. Biweekly telephone interviews during the first year of life assessed diagnoses from doctors' office visits and use of secondary home heating sources, air conditioner use, and day care. Otitis media episodes separated by more than 21 days were considered to be unique episodes. Recurrent otitis media was defined as 4 or more episodes of otitis media. Repeated-measures logistic regression modeling evaluated the association of kerosene heater, fireplace, or wood stove use with otitis media episodes while controlling for potential confounders. Logistic regression evaluated the relation of these secondary heating sources with recurrent otitis media. None of the secondary heating sources were associated with otitis media or with recurrent otitis media. Otitis media was associated with day care, the winter heating season, birth in the fall, white race, additional children in the home, and a maternal history of allergies in multivariate models. Recurrent otitis media was associated with day care, birth in the fall, white race, and a maternal history of allergies or asthma. We found no evidence that the intermittent use of secondary home heating sources increases the risk of otitis media or recurrent otitis media. This study confirms earlier findings regarding the importance of day care with respect to otitis media risk.

  6. Climate change and health: Indoor heat exposure in vulnerable populations☆

    PubMed Central

    White-Newsome, Jalonne L.; Sánchez, Brisa N.; Jolliet, Olivier; Zhang, Zhenzhen; Parker, Edith A.; Dvonch, J. Timothy; O'Neill, Marie S.

    2015-01-01

    Introduction Climate change is increasing the frequency of heat waves and hot weather in many urban environments. Older people are more vulnerable to heat exposure but spend most of their time indoors. Few published studies have addressed indoor heat exposure in residences occupied by an elderly population. The purpose of this study is to explore the relationship between outdoor and indoor temperatures in homes occupied by the elderly and determine other predictors of indoor temperature. Materials and methods We collected hourly indoor temperature measurements of 30 different homes; outdoor temperature, dewpoint temperature, and solar radiation data during summer 2009 in Detroit, MI. We used mixed linear regression to model indoor temperatures’ responsiveness to weather, housing and environmental characteristics, and evaluated our ability to predict indoor heat exposures based on outdoor conditions. Results Average maximum indoor temperature for all locations was 34.85 °C, 13.8 °C higher than average maximum outdoor temperature. Indoor temperatures of single family homes constructed of vinyl paneling or wood siding were more sensitive than brick homes to outdoor temperature changes and internal heat gains. Outdoor temperature, solar radiation, and dewpoint temperature predicted 38% of the variability of indoor temperatures. Conclusions Indoor exposures to heat in Detroit exceed the comfort range among elderly occupants, and can be predicted using outdoor temperatures, characteristics of the housing stock and surroundings PMID:22071034

  7. Bethany Sparn | NREL

    Science.gov Websites

    Sparn Photo of Bethany Sparn Bethany Sparn Researcher IV-Systems Engineering Bethany.Sparn@nrel.gov , residential HVAC equipment, heat pump water heaters, automated home energy management devices, and whole-house Energy Systems Integration Facility which provides a test bed for evaluating home energy management

  8. Technology Solutions Case Study: Long-Term Monitoring of Mini-Split Ductless Heat Pumps in the Northeast, Devens and Easthampton, Massachusetts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Transformations, Inc., has extensive experience building high-performance homes - production and custom - in a variety of Massachusetts locations and uses mini-split heat pumps (MSHPs) for space conditioning in most of its homes. The use of MSHPs for simplified space-conditioning distribution provides significant first-cost savings, which offsets the increased investment in the building enclosure. In this project, the U.S. Department of Energy Building America team Building Science Corporation evaluated the long-term performance of MSHPs in 8 homes during a period of 3 years. The work examined electrical use of MSHPs, distributions of interior temperatures and humidity when using simplified (two-point)more » heating systems in high-performance housing, and the impact of open-door/closed-door status on temperature distributions.« less

  9. Some Basics for Teaching and Evaluating Energy Conservation in the Home

    ERIC Educational Resources Information Center

    McColl, Robert W.

    1978-01-01

    Examines methods for determining thermal efficiency and measuring heat loss in the home. Suggests ways to conserve energy based upon (1) climatic environment and its impact on a structure, (2) physical location of buildings and their microclimate, and (3) behavior modification of the inhabitants. (Author)

  10. Effectiveness and cost of reducing particle-related mortality with particle filtration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisk, W. J.; Chan, W. R.

    This study evaluates the mortality-related benefits and costs of improvements in particle filtration in U.S. homes and commercial buildings based on models with empirical inputs. The models account for time spent in various environments as well as activity levels and associated breathing rates. The scenarios evaluated include improvements in filter efficiencies in both forced-air heating and cooling systems of homes and heating, ventilating, and air conditioning systems of workplaces as well as use of portable air cleaners in homes. The predicted reductions in mortality range from approximately 0.25 to 2.4 per 10 000 population. The largest reductions in mortality were frommore » interventions with continuously operating portable air cleaners in homes because, given our scenarios, these portable air cleaners with HEPA filters most reduced particle exposures. For some interventions, predicted annual mortality-related economic benefits exceed $1000 per person. Economic benefits always exceed costs with benefit-to-cost ratios ranging from approximately 3.9 to 133. In conclusion, restricting interventions to homes of the elderly further increases the mortality reductions per unit population and the benefit-to-cost ratios.« less

  11. Analyzing, Evaluating, and Quantifying the Thermal Energy Contributions of the Passive Solar-Heating Elements Incorporated in the Design and Construction of the Plumblee Residence Located in Alamance County, NC

    DTIC Science & Technology

    2004-08-01

    solar energy economically and environmentally more attractive ( Chiras 2002). In addition, the natural sunlight brought in from large, south-facing...heating principles in the design of any style home ( Chiras 2002). The case study home in this report is the residence of Gordon and Janice Plumblee... Chiras 2002). Special attention is required for designing roof I overhangs including gutters. Overhang lengths without gutters vary from 3.5 feet in hot

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Designing a superinsulated home has many benefits including improved comfort, reduced exterior noise penetration, lower energy bills, and the ability to withstand power and fuel outages under much more comfortable conditions than a typical home. Extremely low heating and cooling loads equate to much smaller HVAC equipment than conventionally required. Sizing the mechanical system to these much lower loads reduces first costs and the size of the distribution system needed. While these homes aren't necessarily constructed with excessive mass in the form of concrete floors and walls, the amount of insulation and the increase in the thickness of the buildingmore » envelope can lead to a mass effect, resulting in the structures ability to store much more heat than a code built home. This results in a very low thermal inertia making the building much less sensitive to drastic temperature swings thereby decreasing the peak heating load demand. Alternative methods that take this inertia into account along with solar and internal gains result in smaller more appropriate design loads than those calculated using Manual J version 8. During the winter of 2013/2014, CARB monitored the energy use of three homes in climate zone 6 in an attempt to evaluate the accuracy of two different mechanical system sizing methods for low load homes. Based on the results, it is recommended that internal and solar gains be included and some credit for thermal inertia be used in sizing calculations for superinsulated homes.« less

  13. Evaluation of the Impact of Slab Foundation Heat Transfer on Heating and Cooling in Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, D.; Kono, J.; Vieira, R.

    During the last three decades of energy-efficiency research, there has been limited study of heat transfer to slab-on-grade foundations in cooling-dominated climates. Most experimental research has focused on the impact of slab-on-grade foundations and insulation schemes on heat losses in heating-dominated climates. This is surprising because the floor area in single-family homes is generally equal to wall area, window area, or attic area, all of which have been extensively evaluated for heat-transfer properties. Moreover, slab foundations are the most common foundation type in cooling-dominated climates. Slab-on-grade construction is very popular in southern states, accounting for 77% of new home floorsmore » according to 2014 U.S. Census data. There is a widespread perception that tile flooring, as opposed to carpet, provides a cooler home interior in warm climates. Empirical research is needed because building energy simulation software programs running DOE-2 and EnergyPlus engines often rely on simplified models to evaluate the influence of flooring on interior temperature, even though in some cases more detailed models exist. The U.S. Department of Energy Building America Partnership for Improved Residential Construction (BA-PIRC) performed experiments in the Florida Solar Energy Center’s Flexible Residential Test Facility intended to assess for the first time (1) how slab-on-grade construction influences interior cooling in a cooling-dominated climate and (2) how the difference in a carpeted versus uncarpeted building might influence heating and cooling energy use. Two nominally identical side-by-side residential buildings were evaluated during the course of 1 year, from 2014 to 2015: the east building with a pad and carpet floor and the west building with a bare slab floor. A detailed grid shows temperature measurements taken on the slab surface at various locations as well as at depths of 1.0 ft, 2 ft, 5.0 ft, 10.0 ft, and 20.0 ft below the surface. Temperature measurements were taken at both buildings for more than 3 years prior to the experiments to ensure that the ground and foundation temperatures had fully come into equilibrium.« less

  14. Chapter 5: Residential Furnaces and Boilers Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W.; Jacobson, David

    The high-efficiency boiler and furnace measure produces gas heating savings resulting from installation of more energy-efficient heating equipment in a residence. Such equipment, which ranges in size from 60 kBtu/hr to 300 kBtu/hr, is installed primarily in single-family homes and multifamily buildings with individual heating systems for each dwelling unit. This protocol does not cover integrated heating and water heating units which can be used in lieu of space heating only equipment.

  15. Probabilistic assessment of the potential indoor air impacts of vent-free gas heating appliances in energy-efficient homes in the United States.

    PubMed

    Whitmyre, Gary K; Pandian, Muhilan D

    2018-06-01

    Use of vent-free gas heating appliances for supplemental heating in U.S. homes is increasing. However, there is currently a lack of information on the potential impact of these appliances on indoor air quality for homes constructed according to energy-efficient and green building standards. A probabilistic analysis was conducted to estimate the impact of vent-free gas heating appliances on indoor air concentrations of carbon monoxide (CO), nitrogen dioxide (NO 2 ), carbon dioxide (CO 2 ), water vapor, and oxygen in "tight" energy-efficient homes in the United States. A total of 20,000 simulations were conducted for each Department of Energy (DOE) heating region to capture a wide range of home sizes, appliance features, and conditions, by varying a number of parameters, e.g., room volume, house volume, outdoor humidity, air exchange rates, appliance input rates (Btu/hr), and house heat loss factors. Predicted airborne levels of CO were below the U.S. Environmental Protection Agency (EPA) standard of 9 ppm for all modeled cases. The airborne concentrations of NO 2 were below the U.S. Consumer Product Safety Commission (CPSC) guideline of 0.3 ppm and the Health Canada benchmark of 0.25 ppm in all cases and were below the World Health Organization (WHO) standard of 0.11 ppm in 99-100% of all cases. Predicted levels of CO 2 were below the Health Canada standard of 3500 ppm for all simulated cases. Oxygen levels in the room of vent-free heating appliance use were not significantly reduced. The great majority of cases in all DOE regions were associated with relative humidity (RH) levels from all indoor water vapor sources that were less than the EPA-recommended 70% RH maximum to avoid active mold and mildew growth. The conclusion of this investigation is that when installed in accordance with the manufacturer's instructions, vent-free gas heating appliances maintain acceptable indoor air quality in tight energy-efficient homes, as defined by the standards referenced in this report. Probabilistic modeling of indoor air concentrations of carbon monoxide (CO), nitrogen dioxide (NO 2 ), carbon dioxide (CO 2 ), water vapor, and oxygen associated with use of vent-free gas heating appliances provides new data indicating that uses of these devices are consistent with acceptable indoor air quality in "tight" energy-efficient homes in the United States. This study will provide authoritative bodies such as the International Code Council with definitive information that will assist in the development of future versions of national building codes, and will provide evaluation of the performance of unvented gas heating products in energy conservation homes.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Designing a superinsulated home has many benefits including improved comfort, reduced exterior noise penetration, lower energy bills, and the ability to withstand power and fuel outages under much more comfortable conditions than a typical home. Extremely low heating and cooling loads equate to much smaller HVAC equipment than conventionally required. Sizing the mechanical system to these much lower loads reduces first costs and the size of the distribution system needed. While these homes aren't necessarily constructed with excessive mass in the form of concrete floors and walls, the amount of insulation and the increase in the thickness of the buildingmore » envelope can lead to a mass effect, resulting in the structures ability to store much more heat than a code built home. This results in a very low thermal inertia making the building much less sensitive to drastic temperature swings thereby decreasing the peak heating load demand. Alternative methods that take this inertia into account along with solar and internal gains result in smaller more appropriate design loads than those calculated using Manual J version 8. During the winter of 2013/2014, the Consortium for Advanced Residential Buildings team monitored the energy use of three homes in climate zone 6 in an attempt to evaluate the accuracy of two different mechanical system sizing methods for low load homes. Based on the results, it is recommended that internal and solar gains be included and some credit for thermal inertia be used in sizing calculations for superinsulated homes.« less

  17. Building America Case Study: Ground Source Heat Pump Research, TaC Studios Residence, Atlanta, Georigia (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2014-09-01

    As part of the NAHB Research Center Industry Partnership, Southface partnered with TaC Studios, an Atlanta based architecture firm specializing in residential and light commercial design, on the construction of a new test home in Atlanta, GA in the mixed-humid climate. This home serves as a residence and home office for the firm's owners, as well as a demonstration of their design approach to potential and current clients. Southface believes the home demonstrates current best practices for the mixed-humid climate, including a building envelope featuring advanced air sealing details and low density spray foam insulation, glazing that exceeds ENERGY STARmore » requirements, and a high performance heating and cooling system. Construction quality and execution was a high priority for TaC Studios and was ensured by a third party review process. Post construction testing showed that the project met stated goals for envelope performance, an air infiltration rate of 2.15 ACH50. The homeowner's wished to further validate whole house energy savings through the project's involvement with Building America and this long-term monitoring effort. As a Building America test home, this home was evaluated to detail whole house energy use, end use loads, and the efficiency and operation of the ground source heat pump and associated systems. Given that the home includes many non-typical end use loads including a home office, pool, landscape water feature, and other luxury features not accounted for in Building America modeling tools, these end uses were separately monitored to determine their impact on overall energy consumption.« less

  18. Side-by-Side Field Evaluation of Highly Insulating Windows in the PNNL Lab Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Widder, Sarah H.; Parker, Graham B.; Baechler, Michael C.

    2012-08-01

    To examine the energy, air leakage, and thermal performance of highly insulating windows, a field evaluation was undertaken in a matched pair of all-electric, factory-built “Lab Homes” located on the Pacific Northwest National Laboratory (PNNL) campus in Richland, Washington. The “baseline” Lab Home B was retrofitted with “standard” double-pane clear aluminum-frame slider windows and patio doors, while the “experimental” Lab Home A was retrofitted with Jeld-Wen® triple-pane vinyl-frame slider windows and patio doors with a U-factor of 0.2 and solar heat gain coefficient of 0.19. To assess the window, the building shell air leakage, energy use, and interior temperatures ofmore » each home were compared during the 2012 winter heating and summer cooling seasons. The measured energy savings in Lab Home B averaged 5,821 watt-hours per day (Wh/day) during the heating season and 6,518 Wh/day during the cooling season. The overall whole-house energy savings of Lab Home B compared to Lab Home A are 11.6% ± 1.53% for the heating season and 18.4 ± 2.06% for the cooling season for identical occupancy conditions with no window coverings deployed. Extrapolating these energy savings numbers based on typical average heating degree days and cooling degree days per year yields an estimated annual energy savings of 12.2%, or 1,784 kWh/yr. The data suggest that highly insulating windows are an effective energy-saving measure that should be considered for high-performance new homes and in existing retrofits. However, the cost effectiveness of the measure, as determined by the simple payback period, suggests that highly insulating window costs continue to make windows difficult to justify on a cost basis alone. Additional reductions in costs via improvements in manufacturing and/or market penetration that continue to drive down costs will make highly insulating windows much more viable as a cost-effective energy efficiency measure. This study also illustrates that highly insulating windows have important impacts on peak load, occupant comfort, and condensation potential, which are not captured in the energy savings calculation. More consistent and uniform interior temperature distributions suggest that highly insulated windows, as part of a high performance building envelope, may enable more centralized duct design and downsized HVAC systems. Shorter, more centralized duct systems and smaller HVAC systems to yield additional cost savings, making highly insulating windows more cost effective as part of a package of new construction or retrofit measures which achieve significant reductions in home energy use.« less

  19. Fuel properties effect on the performance of a small high temperature rise combustor

    NASA Technical Reports Server (NTRS)

    Acosta, Waldo A.; Beckel, Stephen A.

    1989-01-01

    The performance of an advanced small high temperature rise combustor was experimentally determined at NASA-Lewis. The combustor was designed to meet the requirements of advanced high temperature, high pressure ratio turboshaft engines. The combustor featured an advanced fuel injector and an advanced segmented liner design. The full size combustor was evaluated at power conditions ranging from idle to maximum power. The effect of broad fuel properties was studied by evaluating the combustor with three different fuels. The fuels used were JP-5, a blend of Diesel Fuel Marine/Home Heating Oil, and a blend of Suntec C/Home Heating Oil. The fuel properties effect on the performance of the combustion in terms of pattern factor, liner temperatures, and exhaust emissions are documented.

  20. Solar Heated Homes: They're Here

    ERIC Educational Resources Information Center

    Knight, Carlton W., II; Wohlhagen, Linda

    1975-01-01

    Presents a discussion and examples of the two categories into which solar homes have been classified. Classifications are based upon the method by which the sunlight is put to use: energy conversion, utilizing photoelectric cells; and direct heating, where sunlight heats water which then heats the home. Diagrams are presented. (Author/EB)

  1. LONG-TERM PERFORMANCE OF EPA-CERTIFIED PHASE 2 WOODSTOVES, KLAMATH FALLS AND PORTLAND, OREGON: 1998/1999

    EPA Science Inventory

    The report gives results of an evaluation of the condition and air emissions from old, phase-2-certified wood heaters installed in homes and used regularly for hoe heating since the 1992/1993 heating season or earlier. (NOTE: Wood stoves have been identified as a major source of ...

  2. 24 CFR 3280.506 - Heat loss/heat gain.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Heat loss/heat gain. 3280.506... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Thermal Protection § 3280.506 Heat loss/heat gain. The manufactured home heat loss/heat gain shall be determined by methods outlined in...

  3. 24 CFR 3280.506 - Heat loss/heat gain.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Heat loss/heat gain. 3280.506... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Thermal Protection § 3280.506 Heat loss/heat gain. The manufactured home heat loss/heat gain shall be determined by methods outlined in...

  4. 24 CFR 3280.506 - Heat loss/heat gain.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Heat loss/heat gain. 3280.506... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Thermal Protection § 3280.506 Heat loss/heat gain. The manufactured home heat loss/heat gain shall be determined by methods outlined in...

  5. 24 CFR 3280.506 - Heat loss/heat gain.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Heat loss/heat gain. 3280.506... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Thermal Protection § 3280.506 Heat loss/heat gain. The manufactured home heat loss/heat gain shall be determined by methods outlined in...

  6. 24 CFR 3280.506 - Heat loss/heat gain.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Heat loss/heat gain. 3280.506... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Thermal Protection § 3280.506 Heat loss/heat gain. The manufactured home heat loss/heat gain shall be determined by methods outlined in...

  7. Exposure to electromagnetic fields during pregnancy with emphasis on electrically heated beds: association with birthweight and intrauterine growth retardation.

    PubMed

    Bracken, M B; Belanger, K; Hellenbrand, K; Dlugosz, L; Holford, T R; McSharry, J E; Addesso, K; Leaderer, B

    1995-05-01

    Several animal and human studies indicate that fetal growth may be retarded following exposure to electromagnetic fields (EMF). We conducted a prospective study (N = 2,967) to evaluate the relation of birthweight and fetal growth retardation with use of electrically heated beds (electric blankets and heated water beds) during pregnancy. A "nested" study design allowed monitoring of exposure at different stages of pregnancy using both direct and indirect methods. We assessed EMF exposure using personal monitors, home measurement, video display terminal use, and wire code. Exposure to EMF during pregnancy, either at conception, at < or = 16 weeks, or in the third trimester, showed no important relation to risk of low birth-weight or fetal growth retardation. This result was the same whether we used subjective measures of exposure or direct measurement. Use of video display terminals at home or work, exposure to > or = 2.0-milligauss fields as measured by home or personal monitors, and home wire code were unrelated to the reproductive outcomes studied. A time-weighted analysis of electric bed use, which accounted for strength of EMF exposure and hours of use, also showed evidence of no meaningful increase in risk. None of the exposure measures showed a dose response relation to risk. We conclude that risk of low birth-weight and intrauterine growth retardation is not increased after electrically heated bed use during pregnancy.

  8. Geothermal greenhouse-heating facilities for the Klamath County Nursing Home, Klamath Falls, Oregon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The Klamath County Nursing Home, located in Klamath Falls, Oregon, was constructed in 1976. The building of 55,654 square feet currently houses care facilities for approximately 120 persons. During the initial planning for the Nursing Home, the present site was selected primarily on the basis of its geothermal resource. This resource (approx. 190/sup 0/F) currently provides space and domestic hot water heating for the Nursing Home, Merle West Medical Center and the Oregon Institute of Technology. The feasibility of installing a geothermal heating system in a planned greenhouse for the Nursing Home is explored. The greenhouse system would be tiedmore » directly to the existing hot water heating system for the Nursing Home.« less

  9. Building America Case Study: Occupant Comfort from a Mini-Split Heat Pump, San Antonio, Texas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    IBACOS worked with builder Imagine Homes to evaluate the performance of an occupied new construction test house following construction of the house in the hot, humid climate of San Antonio, Texas. The project measures the effectiveness of a space conditioning strategy using a multihead mini-split heat pump (MSHP) system in a reduced-load home to achieve acceptable comfort levels (temperature and humidity) and energy performance. IBACOS collected long-term data and analyzed the energy consumption and comfort conditions of the occupied house after one year of operation. Although measured results indicate that the test system provides comfort both inside and outside themore » ASHRAE Standard 55-2010 range, the occupants of the house claimed both adequate comfort and appreciation of the ease of use and flexibility of the installed MSHP system. IBACOS also assisted the builder to evaluate design and specification changes necessary to comply with Zero Energy Ready Home, but the builder chose to not move forward with it because of concerns about the 'solar ready' requirements of the program.« less

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heat transfer to slab foundations has remained an area of building science with poor understanding over the last three decades of energy efficiency research. This is somewhat surprising since the area of floors in single family homes is generally equal to wall, or windows or attics which have been extensively evaluated. Research that has been done has focused in the impact of slab on grade foundations and insulation schemes on heat losses associated with heating in predominantly heating dominated climates. Slab on grade construction is very popular in cooling-dominated southern states where it accounts for 77 percent of new homemore » floors according to U.S. Census data in 2014. There is a widespread conception that tile flooring, as opposed to carpet, makes for a cooler home interior in warm climates. Empirical research is needed as building energy simulations such as DOE-2 and EnergyPlus rely on simplified models to evaluate these influences. BA-PIRC performed experiments over an entire year from 2014-2015 in FSEC's Flexible Residential Test Facilities (FRTF) intended to assess for the first time 1) slab on grade influence in a cooling dominated climate, and 2) how the difference in a carpeted vs. uncarpeted building might influence heating and cooling. Two identical side by side residential buildings were evaluated, the East with pad and carpet and the west with a bare slab floor. A highly detailed grid of temperature measurements were taken on the slab surface at various locations as well as at depths of 1, 2.5, 5, 10 and 20 feet.« less

  11. Predictors of summertime heat index levels in New York City apartments

    PubMed Central

    Quinn, Ashlinn; Kinney, Patrick; Shaman, Jeffrey

    2018-01-01

    Background During heat waves, fatal overexposure to heat most often occurs at home. It is not known how factors such as building size, floor level, and different types of air conditioning (AC) contribute to excess indoor heat. Methods We monitored indoor temperature and humidity in 36 apartments in New York City during summers 2014 and 2015, and used these values to calculate the indoor heat index (HI). We investigated the role of AC type and building-level factors on indoor HI using multilevel regression models. Results 34 of 36 homes had AC. Central and ductless AC types were associated with the coolest indoor conditions; homes with window and portable AC were significantly warmer. Apartments on the top floor of a building were significantly hotter during heat advisory periods than other apartments regardless of the presence of AC. High indoor HI levels persisted in some homes for approximately one day following the end of the two heat advisory periods. Conclusions We provide concrete evidence of higher heat levels in top floor apartments and in homes with certain types of AC. High heat levels that persist indoors after outdoor heat has subsided may present an underappreciated public health risk. PMID:28107558

  12. Risk Assessment of Heating, Ventilating, and Air-Conditioning Strategies in Low-Load Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poerschke, Andrew

    2016-02-17

    "Modern, energy efficient homes conforming to the Zero Energy Ready Home standard face the challenge of meeting high customer expectations for comfort. Traditional heating, ventilation, and air conditioning (HVAC) sizing and control strategies may be insufficient to adequately condition each zone due to unique load patterns in each room caused by a number of factors. These factors include solar heat gains, occupant-related gains, and gains associated with appliances and electronics. Because of shrinking shell loads, these intermittent factors are having an increasingly significant impact on the thermal load in each zone. Consequently, occupant comfort can be compromised. To evaluate themore » impact of climate and house geometry, as well as HVAC system and control strategies on comfort conditions, IBACOS analyzed the results of 99 TRNSYS multiple-zone simulations. The results of this analysis indicate that for simple-geometry and single-story plans, a single zone and thermostat can adequately condition the entire house. Demanding house geometry and houses with multiple stories require the consideration of multiple thermostats and multiple zones.« less

  13. Evaluation of a Home-Based Environmental and Educational Intervention to Improve Health in Vulnerable Households: Southeastern Pennsylvania Lead and Healthy Homes Program.

    PubMed

    Mankikar, Deepa; Campbell, Carla; Greenberg, Rachael

    2016-09-09

    This evaluation examined whether participation in a home-based environmental educational intervention would reduce exposure to health and safety hazards and asthma-related medical visits. The home intervention program focused on vulnerable, low-income households, where children had asthma, were at risk for lead poisoning, or faced multiple unsafe housing conditions. Home visitors conducted two home visits, two months apart, consisting of an environmental home assessment, Healthy Homes education, and distribution of Healthy Homes supplies. Measured outcomes included changes in participant knowledge and awareness of environmental home-based hazards, rate of children's asthma-related medical use, and the presence of asthma triggers and safety hazards. Analysis of 2013-2014 baseline and post-intervention program data for a cohort of 150 families revealed a significantly lower three-month rate (p < 0.05) of children's asthma-related doctor visits and hospital admissions at program completion. In addition, there were significantly reduced reports of the presence of home-based hazards, including basement or roof leaks (p = 0.011), plumbing leaks (p = 0.019), and use of an oven to heat the home (p < 0.001). Participants' pre- and post- test scores showed significant improvement (p < 0.05) in knowledge and awareness of home hazards. Comprehensive home interventions may effectively reduce environmental home hazards and improve the health of asthmatic children in the short term.

  14. Performance of electrostatic dust collectors (EDCs) for endotoxin assessment in homes: Effect of mailing, placement, heating, and electrostatic charge.

    PubMed

    Kilburg-Basnyat, Brita; Metwali, Nervana; Thorne, Peter S

    2016-01-01

    Electrostatic Dust Collectors (EDCs) are in use for passive sampling of bioaerosols, but particular aspects of their performance have not yet been evaluated. This study investigated the effect of mailing EDCs on endotoxin loading and the effect of EDC deployment in front of, and away from, heated ventilation on endotoxin sampling. Endotoxin sampling efficiency of heated and unheated EDC cloths was also evaluated. Cross-country express mailing of dust-spiked EDCs yielded no significant changes in endotoxin concentrations compared to dust-only samples for both high-spiked EDCs (p = 0.30) and low-spiked EDCs (p = 0.36). EDCs were also deployed in 20 identical apartments with one EDC placed in front of the univent heater in each apartment and contemporaneous EDC placed on the built-in bookshelf in each apartment. The endotoxin concentrations were significantly different (p = 0.049) indicating that the placement of EDC does impact endotoxin sampling. Heated and unheated EDCs were deployed for 7 days in pairs in farm homes. There was a significant difference between endotoxin concentrations (p = 0.027) indicating that heating EDCs may diminish their electrostatic capabilities and impact endotoxin sampling. The last study investigated the electrostatic charge of 12 heated and 12 unheated EDC cloths. There was a significant difference in charge (p = 0.009) which suggests that heating EDC cloths may make them less effective for sampling. In conclusion, EDCs can be mailed to and from deployment sites, EDC placement in relationship to ventilation is crucial, and heating EDCs reduces their electrostatic charge which may diminish their endotoxin sampling capabilities.

  15. Low-cost measurement techniques to characterize the influence of home heating fuel on carbon monoxide in Navajo homes.

    PubMed

    Casey, Joanna Gordon; Ortega, John; Coffey, Evan; Hannigan, Michael

    2018-06-01

    A large fraction of the global population relies on the inefficient combustion of solid fuels for cooking and home heating, resulting in household exposure to combustion byproducts. In the southwestern United States, unhealthy air quality has been observed in some homes that use solid fuels as a primary source of heat on the Navajo Nation. In order to better understand how home heating fuel choice can influence indoor air quality in this region, we used recently developed low-cost electrochemical sensors to measure carbon monoxide (CO) air mole fractions continuously inside and outside 41 homes in two communities on the Navajo Nation. Using low-cost sensors in this study, which don't require extensive training to operate, enabled collaboration with local Diné College students and faculty in the planning and implementation of home deployments. Households used natural gas, propane, pellets, wood, and/or coal for heating. We developed quantification methods that included uncertainty estimation for Alphasense CO-B4 sensors, for measurements both inside and outside homes. CO concentrations elevated above background were observed in homes in each heating fuel group, but the highest hourly concentrations were observed in wood and coal burning homes, some of which exceeded World Health Organization Guidelines on both an hourly and eight-hourly basis. In order to probe the many factors that can influence indoor pollutant concentrations, we developed and implemented methods that employ CO emission and decay time periods observed in homes during everyday activities to estimate air exchange rates as well as CO emission rates on the basis of a given well-mixed volume of air. The air quality measurement tools and methods demonstrated in this study can be readily extended to indoor air quality studies in other communities around the world to inform how home heating and cooking practices are influencing indoor air quality during normal daily activities. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. 24 CFR 3280.510 - Heat loss certificate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Heat loss certificate. 3280.510... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Thermal Protection § 3280.510 Heat... specify the following: (a) Heating zone certification. The design zone at which the manufactured home heat...

  17. 24 CFR 3280.510 - Heat loss certificate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Heat loss certificate. 3280.510... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Thermal Protection § 3280.510 Heat... specify the following: (a) Heating zone certification. The design zone at which the manufactured home heat...

  18. 24 CFR 3280.510 - Heat loss certificate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Heat loss certificate. 3280.510... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Thermal Protection § 3280.510 Heat... specify the following: (a) Heating zone certification. The design zone at which the manufactured home heat...

  19. 24 CFR 3280.510 - Heat loss certificate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Heat loss certificate. 3280.510... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Thermal Protection § 3280.510 Heat... specify the following: (a) Heating zone certification. The design zone at which the manufactured home heat...

  20. 24 CFR 3280.510 - Heat loss certificate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Heat loss certificate. 3280.510... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Thermal Protection § 3280.510 Heat... specify the following: (a) Heating zone certification. The design zone at which the manufactured home heat...

  1. Evaluation of Retrofit Variable-Speed Furnace Fan Motors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aldrich, R.; Williamson, J.

    2014-01-01

    In conjunction with the New York State Energy Research and Development Authority (NYSERDA) and Proctor Engineering Group, Ltd. (PEG), the Consortium for Advanced Residential Buildings (CARB) has evaluated the Concept 3™ replacement motors for residential furnaces. These brushless, permanent magnet (BPM) motors can use much less electricity than their PSC (permanent split capacitor) predecessors. This evaluation focuses on existing homes in the heating-dominated climate of upstate New York with the goals of characterizing field performance and cost effectiveness. The project includes eight homes in and near Syracuse, NY. Tests and monitoring was performed both before and after fan motors weremore » replaced. Results indicate that BPM replacement motors will be most cost effective in HVAC systems with longer run times and relatively low duct static pressures. More dramatic savings are possible if occupants use the fan-only setting when there is no thermal load. There are millions of cold-climate, U.S. homes that meet these criteria, but the savings in most homes tested in this study were modest.« less

  2. 24 CFR 3280.507 - Comfort heat gain.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Comfort heat gain. 3280.507 Section... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Thermal Protection § 3280.507 Comfort heat... part. (a) Transmission heat gains. Homes complying with this section shall meet the minimum heat loss...

  3. 24 CFR 3280.507 - Comfort heat gain.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Comfort heat gain. 3280.507 Section... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Thermal Protection § 3280.507 Comfort heat... part. (a) Transmission heat gains. Homes complying with this section shall meet the minimum heat loss...

  4. 24 CFR 3280.507 - Comfort heat gain.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Comfort heat gain. 3280.507 Section... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Thermal Protection § 3280.507 Comfort heat... part. (a) Transmission heat gains. Homes complying with this section shall meet the minimum heat loss...

  5. 24 CFR 3280.507 - Comfort heat gain.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Comfort heat gain. 3280.507 Section... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Thermal Protection § 3280.507 Comfort heat... part. (a) Transmission heat gains. Homes complying with this section shall meet the minimum heat loss...

  6. Predictors of summertime heat index levels in New York City apartments.

    PubMed

    Quinn, A; Kinney, P; Shaman, J

    2017-07-01

    During heat waves, fatal overexposure to heat most often occurs at home. It is not known how factors such as building size, floor level, and different types of air conditioning (AC) contribute to excess indoor heat. We monitored indoor temperature and humidity in 36 apartments in New York City during summers 2014 and 2015 and used these values to calculate the indoor heat index (HI). We investigated the role of AC type and building-level factors on indoor HI using multilevel regression models. Thirty-four of 36 homes had AC. Central and ductless AC types were associated with the coolest indoor conditions; homes with window and portable AC were significantly warmer. Apartments on the top floor of a building were significantly hotter during heat advisory periods than other apartments regardless of the presence of AC. High indoor HI levels persisted in some homes for approximately 1 day following the end of the two heat advisory periods. We provide concrete evidence of higher heat levels in top floor apartments and in homes with certain types of AC. High heat levels that persist indoors after outdoor heat has subsided may present an underappreciated public health risk. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. When energy saving advice leads to more, rather than less, consumption

    NASA Astrophysics Data System (ADS)

    Revell, Kirsten M. A.; Stanton, Neville A.

    2017-01-01

    Energy saving technology that relies on behaviour change fails to deliver on its promise. Energy saving advice also has limited effect. This paper examines and reveals how technology and energy saving advice interacts with householders' thought processes to influence energy consumption. A case study of three households that held a 'Feedback' mental model of the home heating thermostat, as defined by Kempton [1986. 'Two Theories of Home Heat Control'. Cognitive Science 10 (1): 75-90], was undertaken to understand the driver behind differences in their home heating strategies, and the effect on energy consumption. Analysis was undertaken from five different data sources comprising: (1) boiler on durations, (2) thermostat set point adjustments, (3) self-reported strategies with home heating controls, (4) user mental model descriptions of the home heating system, and (5) Interview transcripts. The authors found that differences in user mental models of home heating at the system level explained differences in the strategies chosen at the control device level. Differences in boiler on periods were found to relate to limitations of the 'Feedback' mental model; that is, the model fails to consider the effect of the movement of warm air within the home and the impact of internal/external temperature differentials on heat loss rates. The authors argue that technology and advice should be tailored to the thought processes adopted by householders in order to promote behaviour that would realise intended energy savings.

  8. Energy Considerations in Home Mortgages: An Evaluation Technique.

    ERIC Educational Resources Information Center

    Maine Audubon Society, Falmouth.

    This document, intended primarily for mortgage lenders, is designed to aid readers in evaluating solar heating technology in the aspects of its capital cost and potential for recovery of investment. Whether or not American consumers will fully exploit this alternative will depend upon interest rates, the allocation of capital to finance the higher…

  9. Home delivery of heat-stable vaccines in Indonesia: outreach immunization with a prefilled, single-use injection device.

    PubMed Central

    Sutanto, A.; Suarnawa, I. M.; Nelson, C. M.; Stewart, T.; Soewarso, T. I.

    1999-01-01

    Extending immunization coverage to underserved populations will require innovative immunization strategies. This study evaluated one such strategy: the use of a prefilled, single-use injection device for outreach immunization by village midwives. The device, UniJect, is designed to prevent refilling or reuse. Stored at ambient temperatures for up to 1 month in midwives' homes, vaccine-filled UniJect devices were immediately available for outreach. Between July 1995 and April 1996, 110 midwives on the Indonesia islands of Lombok and Bali visited the homes of newborn infants to deliver hepatitis B vaccine to the infants and tetanus toxoid to their mothers. Observations and interviews showed that the midwives used the device properly and safely to administer approximately 10,000 sterile injections in home settings. There were no problems with excessive heat exposure during the storage or delivery of vaccine. Injection recipients and midwives expressed a strong preference for the UniJect device over a standard syringe. Use of the prefilled device outside the cold chain simplified the logistics and facilitated the speed and efficiency of home visits, while the single-dose format minimized vaccine wastage. PMID:10083709

  10. Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes -- Habitat for Humanity The Woods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lubliner, Michael; Howard, Luke; Hales, David

    The Woods is a Habitat for Humanity (HFH) community of ENERGY STAR Homes Northwest (ESHNW)-certified homes located in the marine climate of Tacoma/Pierce County, Washington. This research report builds on an earlier preliminary draft 2014 BA report, and includes significant billing analysis and cost effectiveness research from a collaborative, ongoing Ductless Heat Pump (DHP)research effort for Tacoma Public Utilities (TPU) and Bonneville Power Administration (BPA). This report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and Octobermore » 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing such as HFH. Tacoma Public Utilities (TPU) and Bonneville Power Administration (BPA). This report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing such as HFH.« less

  11. Karasek Home, Blackstone, Massachusetts solar-energy-system performance evaluation, Nov. 1981 - Mar. 1982

    NASA Astrophysics Data System (ADS)

    Raymond, M.

    1982-06-01

    The Karasek Home is a single family Massachusetts residence whose active-solar-energy system is equipped with 640 square feet of trickle-down liquid flat-plate collectors, storage in a 300-gallon tank and a 2000-gallon tank embedded in a rock bin in the basement, and an oil-fired glass-lined 40-gallon domestic hot water tank for auxiliary water and space heating. Monthly performance data are tabulated for the overall system and for the collector, storage, space heating, and domestic hot water subsystems. For each month a graph is presented of collector array efficiency versus the difference between the inlet water temperature and ambient temperature divided by insolation. Typical system operation is illustrated by graphs of insolation and temperatures at different parts of the system versus time for a typical day. The typical system operating sequence for a day is also graphed as well as solar energy utilization and heat losses.

  12. Building America Case Study: Impact of Slab-Foundation Heat Transfer on Space-Conditioning Energy Use in Florida, Cocoa, Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D. Parker, E. Martin

    Heat transfer to slab foundations has remained an area of building science with poor understanding over the last three decades of energy efficiency research. This is somewhat surprising since the area of floors in single family homes is generally equal to wall, or windows or attics which have been extensively evaluated. Research that has been done has focused in the impact of slab on grade foundations and insulation schemes on heat losses associated with heating in predominantly heating dominated climates. Slab on grade construction is very popular in cooling-dominated southern states where it accounts for 77 percent of new homemore » floors according to U.S. Census data in 2014. There is a widespread conception that tile flooring, as opposed to carpet, makes for a cooler home interior in warm climates. Empirical research is needed as building energy simulations such as DOE-2 and EnergyPlus rely on simplified models to evaluate these influences. BA-PIRC performed experiments over an entire year from 2014-2015 in FSEC's Flexible Residential Test Facilities (FRTF) intended to assess for the first time 1) slab on grade influence in a cooling dominated climate, and 2) how the difference in a carpeted vs. uncarpeted building might influence heating and cooling. Two identical side by side residential buildings were evaluated, the East with pad and carpet and the west with a bare slab floor. A highly detailed grid of temperature measurements were taken on the slab surface at various locations as well as at depths of 1, 2.5, 5, 10 and 20 feet.« less

  13. Efficient Solutions for New Homes Case Study: Savannah Gardens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2016-03-15

    The Savannah Housing Department is leading sustainable and affordable housing development in Georgia. It partnered with Southface Energy Institute, a member of the U.S. Department of Energy’s Partnership for Home Innovation Building America research team, to seek cost-effective solutions for increasing the energy efficiency of the Savannah Housing Department’s standard single-family home plans in the Savannah Gardens Community. Based on engineering, cost, and constructability analyses, the combined research team chose to pilot two technologies to evaluate efficiency and comfort impacts for homeowners: a heat-pump water heater in an encapsulated attic and an insulated exterior wall sheathing.

  14. Heat penetration and thermocouple location in home canning.

    PubMed

    Etzel, Mark R; Willmore, Paola; Ingham, Barbara H

    2015-01-01

    We processed applesauce, tomato juice, and cranberries in pint jars in a boiling water canner to test thermal processing theories against home canning of high-acid foods. For each product, thermocouples were placed at various heights in the jar. Values for f h (heating), f cl (cooling), and F 82.2°C (lethality) were determined for each thermocouple location, and did not depend substantially on thermocouple location in accordance with heat transfer theory. There was a cold spot in the jar, but the cold spot during heating became the hot spot during cooling. During heating, the geometric center was the last to heat, and remained coldest the longest, but during coooling, it was also the last to cool, and remained hottest the longest. The net effect was that calculated lethality in home canning was not affected by thermocouple location. Most of the lethality during home canning occurred during air cooling, making cooling of home canned foods of great importance. Calculated lethality was far greater than the required 5-log reduction of spores in tomato juice and vegetative cells in cranberries, suggesting a wide margin of safety for approved home-canning processes for high-acid foods.

  15. Heat penetration and thermocouple location in home canning

    PubMed Central

    Etzel, Mark R; Willmore, Paola; Ingham, Barbara H

    2015-01-01

    We processed applesauce, tomato juice, and cranberries in pint jars in a boiling water canner to test thermal processing theories against home canning of high-acid foods. For each product, thermocouples were placed at various heights in the jar. Values for fh (heating), fcl (cooling), and F82.2°C (lethality) were determined for each thermocouple location, and did not depend substantially on thermocouple location in accordance with heat transfer theory. There was a cold spot in the jar, but the cold spot during heating became the hot spot during cooling. During heating, the geometric center was the last to heat, and remained coldest the longest, but during coooling, it was also the last to cool, and remained hottest the longest. The net effect was that calculated lethality in home canning was not affected by thermocouple location. Most of the lethality during home canning occurred during air cooling, making cooling of home canned foods of great importance. Calculated lethality was far greater than the required 5-log reduction of spores in tomato juice and vegetative cells in cranberries, suggesting a wide margin of safety for approved home-canning processes for high-acid foods. PMID:25649758

  16. Evaluation of a Home-Based Environmental and Educational Intervention to Improve Health in Vulnerable Households: Southeastern Pennsylvania Lead and Healthy Homes Program

    PubMed Central

    Mankikar, Deepa; Campbell, Carla; Greenberg, Rachael

    2016-01-01

    This evaluation examined whether participation in a home-based environmental educational intervention would reduce exposure to health and safety hazards and asthma-related medical visits. The home intervention program focused on vulnerable, low-income households, where children had asthma, were at risk for lead poisoning, or faced multiple unsafe housing conditions. Home visitors conducted two home visits, two months apart, consisting of an environmental home assessment, Healthy Homes education, and distribution of Healthy Homes supplies. Measured outcomes included changes in participant knowledge and awareness of environmental home-based hazards, rate of children’s asthma-related medical use, and the presence of asthma triggers and safety hazards. Analysis of 2013–2014 baseline and post-intervention program data for a cohort of 150 families revealed a significantly lower three-month rate (p < 0.05) of children’s asthma-related doctor visits and hospital admissions at program completion. In addition, there were significantly reduced reports of the presence of home-based hazards, including basement or roof leaks (p = 0.011), plumbing leaks (p = 0.019), and use of an oven to heat the home (p < 0.001). Participants’ pre- and post- test scores showed significant improvement (p < 0.05) in knowledge and awareness of home hazards. Comprehensive home interventions may effectively reduce environmental home hazards and improve the health of asthmatic children in the short term. PMID:27618087

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butler, T.; Curtis, O.; Stephenson, R.

    As part of the NAHB Research Center Industry Partnership, Southface partnered with TaC Studios, an Atlanta-based architecture firm specializing in residential and light commercial design, on the construction of a new test home in Atlanta, GA, in the mixed humid climate. This home serves as a residence and home office for the firm's owners, as well as a demonstration of their design approach to potential and current clients. Southface believes the home demonstrates current best practices for the mixed-humid climate, including a building envelope featuring advanced air sealing details and low density spray foam insulation, glazing that exceeds ENERGY STARmore » requirements, and a high performance heating and cooling system. Construction quality and execution was a high priority for TaC Studios and was ensured by a third party review process. Post-construction testing showed that the project met stated goals for envelope performance, an air infiltration rate of 2.15 ACH50. The homeowners wished to further validate whole house energy savings through the project's involvement with Building America and this long-term monitoring effort. As a Building America test home, this home was evaluated to detail whole house energy use, end use loads, and the efficiency and operation of the ground source heat pump and associated systems. Given that the home includes many non-typical end use loads including a home office, pool, landscape water feature, and other luxury features not accounted for in Building America modeling tools, these end uses were separately monitored to determine their impact on overall energy consumption.« less

  18. Performance of Electrostatic Dust Collectors (EDCs) for Endotoxin Assessment in Homes: Effect of Mailing, Placement, Heating and Electrostatic Charge

    PubMed Central

    Kilburg-Basnyat, Brita; Metwali, Nervana; Thorne, Peter S.

    2016-01-01

    Electrostatic Dust Collectors (EDCs) are in use for passive sampling of bioaerosols, but particular aspects of their performance have not yet been evaluated. This study investigated the effect of mailing EDCs on endotoxin loading and the effect of EDC deployment in front of and away from heated ventilation on endotoxin sampling. Endotoxin sampling efficiency of heated and unheated EDC cloths was also evaluated. Cross-country express mailing of dust-spiked EDCs yielded no significant changes in endotoxin concentrations compared to dust-only samples for both high spiked-EDCs (p=0.30) and low spiked-EDCs (p=0.36). EDCs were also deployed in 20 identical apartments with one EDC placed in front of the univent heater in each apartment and contemporaneous EDC placed on the built-in bookshelf in each apartment. The endotoxin concentrations were significantly different (p=0.049) indicating that the placement of EDC does impact endotoxin sampling. Heated and unheated EDCs were deployed for 7 days in pairs in farm homes. There was a significant difference between endotoxin concentrations (p=0.027) indicating that heating EDCs may diminish their electrostatic capabilities and impact endotoxin sampling. The last study investigated the electrostatic charge of 12 heated and 12 unheated EDC cloths. There was a significant difference in charge (p=0.009) which suggests that heating EDC cloths may make them less effective for sampling. In conclusion, EDCs can be mailed to and from deployment sites, EDC placement in relationship to ventilation is crucial, and heating EDCs reduces their electrostatic charge which may diminish their endotoxin sampling capabilities. PMID:26325020

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, D.; Sutherland, K.; Chasar, D.

    The U.S. Department of Energy (DOE) Building America program, in collaboration with Florida Power and Light (FPL), conducted a phased residential energy-efficiency retrofit program. This research sought to establish impacts on annual energy and peak energy reductions from the technologies applied at two levels of retrofit - shallow and deep, with savings levels approaching the Building America program goals of reducing whole-house energy use by 40%. Under the Phased Deep Retrofit (PDR) project, we have installed phased, energy-efficiency retrofits in a sample of 56 existing, all-electric homes. End-use savings and economic evaluation results from the phased measure packages and singlemore » measures are summarized in this report. Project results will be of interest to utility program designers, weatherization evaluators, and the housing remodel industry. Shallow retrofits were conducted in all homes from March to June 2013. The measures for this phase were chosen based on ease of installation, targeting lighting (CFLs and LED lamps), domestic hot water (wraps and showerheads), refrigeration (cleaning of coils), pool pump (reduction of operating hours), and the home entertainment center (smart plugs). Deep retrofits were conducted on a subset of ten PDR homes from May 2013 through March 2014. Measures included new air source heat pumps, duct repair, ceiling insulation, heat pump water heaters, variable speed pool pumps and learning thermostats. Major appliances such as refrigerators and dishwashers were replaced where they were old and inefficient.« less

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lapsa, Melissa Voss; Khowailed, Gannate

    The heating and cooling equipment market in the United States (U.S.) evolved in the last two decades affected by the housing market and external market conditions. The average home size increased by 25% since 1999, contributing to increased average equipment size of heat pumps (HPs) and air conditioners (ACs). The home size increase did not correlate with higher residential energy used. The last decade is recognized for improved home insulation and equipment efficiency, which has made up for the larger home size and still yielded lower residential energy use. The lower energy use coincides with more homes using HPs. HPmore » growth was supported by the price stability and affordability of electricity. The heating and cooling equipment market also seems to be rebounding faster than the housing market after the economic crises. In 2009 only 22% of HPs were sold to new homes, reflecting increased heat pump sales for add-on and replacement applications. HPs are growing in popularity and becoming an established economic technology. The increased usage of HPs will result in reduced residential heating energy use and carbon dioxide emissions.« less

  1. Technical Report on DOMICE Simulation Model

    DTIC Science & Technology

    2012-04-01

    Branch GPS Global Positioning System HHO home heating oil LCA Lake Carriers’ Association MAR USCG Domestic Icebreaking Mission Analysis...cargo types considered in the module. The module groups the four types of cargo into two broader categories, namely, Home Heating Oil ( HHO ) shipments...or Non- HHO shipments. Table 11. Cargo types. Types of Cargo Cargo Group Dry Bulk Non- HHO Liquid Bulk Perishable / Food Home Heating Oil HHO

  2. Electric home heating: Substitution for oil and gas

    NASA Astrophysics Data System (ADS)

    Burwell, C. C.; Devine, W. D., Jr.; Phung, D. L.

    1982-03-01

    The objective of the research is to determine the potential for substituting electricity generated with surplus coal and nuclear capacity for gas and oil used for home heating. The relative effectiveness of electric heating was determined by an analysis of the purposes of extra winter sales of electricity to the residential sector compared to a similar analysis for extra winter sales of natural gas. The price of electricity for heating is determined based on utility rate structures for selected utilities (primarily located in the north and south central portions of the country) having surplus coal and nuclear capacity throughout the decade of the 1980s. It is found that, on the average, the overall efficiency of fuel use for heating homes electrically is comparable to the use of combustion systems in the home and that electric heating is substantially less costly than direct heating with oil in regions where coal and uranium are the primary fuels used for power generation.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, D.; Kono, J.; Vieira, R.

    During the last three decades of energy-efficiency research, there has been limited study of heat transfer to slab-on-grade foundations in cooling-dominated climates. Most experimental research has focused on the impact of slab-on-grade foundations and insulation schemes on heat losses in heating-dominated climates. This is surprising because the floor area in single-family homes is generally equal to wall area, window area, or attic area, all of which have been extensively evaluated for heat-transfer properties. Moreover, slab foundations are the most common foundation type in cooling-dominated climates. Slab-on-grade construction is very popular in southern states, accounting for 77% of new home floorsmore » according to 2014 U.S. Census data. There is a widespread perception that tile flooring, as opposed to carpet, provides a cooler home interior in warm climates. Empirical research is needed because building energy simulation software programs running DOE-2 and EnergyPlus engines often rely on simplified models to evaluate the influence of flooring on interior temperature, even though in some cases more detailed models exist. The U.S. Department of Energy Building America Partnership for Improved Residential Construction (BA-PIRC) performed experiments in the Florida Solar Energy Center’s Flexible Residential Test Facility intended to assess for the first time (1) how slab-on-grade construction influences interior cooling in a cooling-dominated climate and (2) how the difference in a carpeted versus uncarpeted building might influence heating and cooling energy use. Two nominally identical side-by-side residential buildings were evaluated during the course of 1 year, from 2014 to 2015: the east building with a pad and carpet floor and the west building with a bare slab floor. A detailed grid shows temperature measurements taken on the slab surface at various locations as well as at depths of 1.0 ft, 2 ft, 5.0 ft, 10.0 ft, and 20.0 ft below the surface. Temperature measurements were taken at both buildings for more than 3 years prior to the experiments to ensure that the ground and foundation temperatures had fully come into equilibrium.« less

  4. Building America Case Study: Supplemental Ductless Mini-Split Heat Pump in the Hot-Humid Climate, Brevard and Volusia Counties, Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    "The BAPIRC team and Florida Power and Light (FPL) electric utility pursued a pilot phased energy-efficiency retrofit program in Florida by creating detailed data on the energy and economic performance of two levels of retrofit - simple and deep. For this Phased Deep Retrofit (PDR) project, a total of 56 homes spread across the utility partner's territory in east central Florida, southeast Florida, and southwest Florida were instrumented between August 2012 and January 2013, and received simple pass-through retrofit measures during the period of March 2013 - June 2013. Ten of these homes received a deeper package of retrofits duringmore » August 2013 - December 2013. A full account of Phase I of this project, including detailed home details and characterization, is found in Parker et al, 2015 (currently in draft). Phase II of this project, which is the focus of this report, applied the following additional retrofit measures to select homes that received a shallow retrofit in Phase I: supplemental mini-split heat pump (MSHP) (6 homes), ducted and space coupled heat pump water heater (8 homes), exterior insulation finish system (EIFS) (1 homes), window retrofit (3 homes), smart thermostat (21 homes: 19 NESTs; 2 Lyrics), heat pump clothes dryer (8 homes), and variable speed pool pump (5 homes).« less

  5. Solar Schematic

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The home shown at right is specially designed to accommodate solar heating units; it has roof planes in four directions, allowing placement of solar collectors for best exposure to the sun. Plans (bottom) and complete working blueprints for the solar-heated house are being marketed by Home Building Plan Service, Portland, Oregon. The company also offers an inexpensive schematic (center) showing how a homeowner only moderately skilled in the use of tools can build his own solar energy system, applicable to new or existing structures. The schematic is based upon the design of a low-cost solar home heating system built and tested by NASA's Langley Research Center; used to supplement a warm-air heating system, it can save the homeowner about 40 percent of his annual heating bill for a modest investment in materials and components. Home Building Plan Service saved considerable research time by obtaining a NASA technical report which details the Langley work. The resulting schematic includes construction plans and simplified explanations of solar heat collection, collectors and other components, passive heat factors, domestic hot water supply and how to work with local heating engineers.

  6. Evaluation of Cellular Shades in the PNNL Lab Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petersen, Joseph M.; Sullivan, Greg; Cort, Katherine A.

    This report examines the energy performance of cellular shade window coverings in a matched pair of all-electric, factory-built “Lab Homes” located on the Pacific Northwest National Laboratory (PNNL) campus in Richland, Washington. The 1500-square-foot homes were identical in construction and baseline performance, which allowed any difference in energy and thermal performance between the baseline home and the experimental home to be attributed to the retrofit technology installed in the experimental home. To assess the performance of high efficiency window attachments in a residential retrofit application, the building shell air leakage, energy use, and interior temperatures of each home were comparedmore » during the 2015 -2016 winter heating and summer cooling seasons. Hunter Douglas Duette® Architella® Trielle™ opaque honeycomb “cellular” shades were installed over double-pane clear-glass, aluminum-frame primary windows in the experimental home and were compared to identical primary windows with no window coverings and with standard typical white vinyl horizontal blind window coverings in the baseline home.« less

  7. Thermostat Interface and Usability: A Survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meier, Alan; Peffer, Therese; Pritoni, Marco

    2010-09-04

    This report investigates the history of thermostats to better understand the context and legacy regarding the development of this important tool, as well as thermostats' relationships to heating, cooling, and other environmental controls. We analyze the architecture, interfaces, and modes of interaction used by different types of thermostats. For over sixty years, home thermostats have translated occupants' temperature preferences into heating and cooling system operations. In this position of an intermediary, the millions of residential thermostats control almost half of household energy use, which corresponds to about 10percent of the nation's total energy use. Thermostats are currently undergoing rapid developmentmore » in response to emerging technologies, new consumer and utility demands, and declining manufacturing costs. Energy-efficient homes require more careful balancing of comfort, energy consumption, and health. At the same time, new capabilities will be added to thermostats, including scheduling, control of humidity and ventilation, responsiveness to dynamic electricity prices, and the ability to join communication networks inside homes. Recent studies have found that as many as 50percent of residential programmable thermostats are in permanent"hold" status. Other evaluations found that homes with programmable thermostats consumed more energy than those relying on manual thermostats. Occupants find thermostats cryptic and baffling to operate because manufacturers often rely on obscure, and sometimes even contradictory, terms, symbols, procedures, and icons. It appears that many people are unable to fully exploit even the basic features in today's programmable thermostats, such as setting heating and cooling schedules. It is important that people can easily, reliably, and confidently operate thermostats in their homes so as to remain comfortable while minimizing energy use.« less

  8. Solar Hot Water Heater

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The solar panels pictured below, mounted on a Moscow, Idaho home, are part of a domestic hot water heating system capable of providing up to 100 percent of home or small business hot water needs. Produced by Lennox Industries Inc., Marshalltown, Iowa, the panels are commercial versions of a collector co-developed by NASA. In an effort to conserve energy, NASA has installed solar collectors at a number of its own facilities and is conducting research to develop the most efficient systems. Lewis Research Center teamed with Honeywell Inc., Minneapolis, Minnesota to develop the flat plate collector shown. Key to the collector's efficiency is black chrome coating on the plate developed for use on spacecraft solar cells, the coating prevents sun heat from "reradiating," or escaping outward. The design proved the most effective heat absorber among 23 different types of collectors evaluated in a Lewis test program. The Lennox solar domestic hot water heating system has three main components: the array of collectors, a "solar module" (blue unit pictured) and a conventional water heater. A fluid-ethylene glycol and water-is circulated through the collectors to absorb solar heat. The fluid is then piped to a double-walled jacket around a water tank within the solar module.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butler, T.; Curtis, O.; Stephenson, R.

    As part of the NAHB Research Center Industry Partnership, Southface partnered with TaC Studios, an Atlanta-based architecture firm specializing in residential and light commercial design, on the construction of a new test home in Atlanta, GA in the mixed humid climate. This home serves as a residence and home office for the firm's owners, as well as a demonstration of their design approach topotential and current clients. Southface believes the home demonstrates current best practices for the mixed-humid climate, including a building envelope featuring advanced air sealing details and low density spray foam insulation, glazing that exceeds ENERGY STAR requirements,more » and a high performance heating and cooling system. Construction quality and execution was a high priority for TaCStudios and was ensured by a third party review process. Post-construction testing showed that the project met stated goals for envelope performance, an air infiltration rate of 2.15 ACH50. The homeowners wished to further validate whole house energy savings through the project's involvement with Building America and this long-term monitoring effort. As a Building America test home, this homewas evaluated to detail whole house energy use, end use loads, and the efficiency and operation of the ground source heat pump and associated systems. Given that the home includes many non-typical end use loads including a home office, pool, landscape water feature, and other luxury features not accounted for in Building America modeling tools, these end uses were separately monitored todetermine their impact on overall energy consumption.« less

  10. Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes -- Habitat for Humanity The Woods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michael Lubliner; Howard, Luke; Hales, David

    2016-02-23

    This final Building America Partnership report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing.

  11. Building America Case Study: Performance and Costs of Ductless Heat Pumps in Marine Climate High-Performance Homes: Habitat for Humanity -- The Woods, Tacoma, Washington

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    The Woods is a Habitat for Humanity (HFH) community of ENERGY STAR Homes (c) Northwest (ESHNW)-certified homes located in the marine climate of Tacoma/Pierce County, Washington. This research report builds on an earlier preliminary draft 2014 BA report, and includes significant billing analysis and cost effectiveness research from a collaborative, ongoing Ductless Heat Pump (DHP) research effort for Tacoma Public Utilities (TPU) and Bonneville Power Administration (BPA). This report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013more » and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing such as HFH.« less

  12. Achieving Very High Efficiency and Net Zero Energy in an Existing Home in a Hot-Humid Climate: Long-Term Utility and Monitoring Data (Revised)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, D.; Sherwin, J.

    2012-10-01

    This study summarizes the first six months of detailed data collected on a single family home that experienced a series of retrofits targeting reductions in energy use. The project was designed to develop data on how envelope modifications and renewable measures can result in considerable energy reductions and potentially net zero energy for an existing home. Originally published in February 2012, this revised version of the report contains further research conducted on the Parker residence. Key updates include one full year of additional data, an analysis of cooling performance of the mini-split heat pump, an evaluation of room-to-room temperature distribution,more » and an evaluation of plug-in automobile charging performance, electricity consumption, and load shape.« less

  13. Achieving Very High Efficiency and Net Zero Energy in an Existing Home in a Hot-Humid Climate. Long-Term Utility and Monitoring Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, D.; Sherwin, J.

    2012-10-01

    This study summarizes the first six months of detailed data collected on a single family home that experienced a series of retrofits targeting reductions in energy use. The project was designed to develop data on how envelope modifications and renewable measures can result in considerable energy reductions and potentially net zero energy for an existing home. Originally published in February 2012, this revised version of the report contains further research conducted on the Parker residence. Key updates include one full year of additional data, an analysis of cooling performance of the mini-split heat pump, an evaluation of room-to-room temperature distribution,more » and an evaluation of plug-in automobile charging performance, electricity consumption, and load shape.« less

  14. An Analysis of Water-to-Air Heat Pump Systems for Use in Government Facilities.

    DTIC Science & Technology

    1980-09-01

    factories , businesses, and homes could have a significant impact on total energy con- sumption. Various methods to reduce energy consumption include...MODEL GROUND WATER HEAT PUMP 95 ECOsOioIC: EVALUATION OF 4E i Il/C 0"C". 5InULATI -’ (S 4.’V;F, TEAx3 EC3OO, tC ANALISIS -ARlE7ERS E’NNtNG Yf. OF S:h

  15. 24 CFR 3280.702 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... a comfort cooling appliance where the condenser section is placed external to the manufactured home... a comfort cooling appliance where the condenser section is placed external to the manufactured home... case of a heat pump) heat air for use in comfort cooling (or heating) the living space. Air...

  16. Inexpensive economical solar heating system for homes (un sistema economico de calefaccion solar para viviendas)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alfred, J.W.; Shinn, J.M. Jr; Kirby, C.E.

    1976-07-01

    This report describes a low-cost solar home heating system to supplement the home-owner's present warm-air heating system. It has three parts: (1) A brief background on solar heating, (2) Langley's experience with a demonstration system, and (3) information for the home-owner who wishes to construct such a system. Instructions are given for a solar heating installation in which he supplies all labor needed to install off-the-shelf components estimated to cost $2000. These components, which include solar collector, heat exchanger, water pump, storage tank, piping, and controls to make the system completely automatic, are readily available at local lumber yards, hardwaremore » stores, and plumbing supply stores, and they are relatively simple to install. Manufacturers and prices of each component used and a rough cost analysis based on these prices are given for the owner's convenience. This report also gives performance data obtained from a demonstration system which has been built and tested at the Langley Research Center.« less

  17. Insulation Fact Sheet.

    ERIC Educational Resources Information Center

    Conservation and Renewable Energy Inquiry and Referral Service (DOE), Silver Spring, MD.

    Heating and cooling account for 50-70% of the energy consumed in the average American home. Heating water accounts for another 20%. A poorly insulated home loses much of this energy, causing drafty rooms and high energy bills. This fact sheet discusses how to determine if your home needs more insulation, the additional thermal resistance (called…

  18. Soybean-derived biofuels and home heating fuels.

    PubMed

    Mushrush, George W; Wynne, James H; Willauer, Heather D; Lloyd, Christopher L

    2006-01-01

    It is environmentally enticing to consider replacing or blending petroleum derived heating fuels with biofuels for many reasons. Major considerations include the soaring worldwide price of petroleum products, especially home heating oil, the toxicity of the petroleum-derived fuels and the environmental damage that leaking petroleum tanks afford. For these reasons, it has been suggested that domestic renewable energy sources be considered as replacements, or at the least, as blending stocks for home heating fuels. If recycled soy restaurant cooking oils could be employed for this purpose, this would represent an environmental advantage. Renewable plant sources of energy tend to be less toxic than their petroleum counterparts. This is an important consideration when tank leakage occurs. Home fuel oil storage tanks practically always contain some bottom water. This water environment has a pH value that factors into heating fuel stability. Therefore, the question is: would the biofuel help or exacerbate fuel stability and furnace maintenance issues?

  19. Energy Savers: Tips on Saving Money & Energy at Home

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.

  20. Energy Saver: Tips on Saving Money & Energy at Home

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.

  1. Reducing energy costs in nursing homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The handbook presents ideas and techniques for energy conservation in nursing homes. Case studies were developed of nursing homes located in different parts of the US. The typical nursing home assessed was proprietary, of intermediate-care level, medicaid-certified, and had less than 200 beds. Specific energy conservation measures were analyzed to determine the energy and dollar savings that could be realized. These include reducing heat loss through the building shell; reducing hot water costs; recovering the heat generated by dryers; reducing lighting costs; reducing heating and cooling costs, and analyzing fuels and fuel rates. A case for converting electric clothes dryersmore » to gas was analyzed. (MCW)« less

  2. Drivers and barriers to heat stress resilience.

    PubMed

    Hatvani-Kovacs, Gertrud; Belusko, Martin; Skinner, Natalie; Pockett, John; Boland, John

    2016-11-15

    Heatwaves are the most dangerous natural hazard to health in Australia. The frequency and intensity of heatwaves will increase due to climate change and urban heat island effects in cities, aggravating the negative impacts of heatwaves. Two approaches exist to develop population heat stress resilience. Firstly, the most vulnerable social groups can be identified and public health services can prepare for the increased morbidity. Secondly, the population level of adaptation and the heat stress resistance of the built environment can be increased. The evaluation of these measures and their efficiencies has been fragmented across research disciplines. This study explored the relationships between the elements of heat stress resilience and their potential demographic and housing drivers and barriers. The responses of a representative online survey (N=393) about heat stress resilience at home and work from Adelaide, South Australia were analysed. The empirical findings demonstrate that heat stress resistant buildings increased adaptation capacity and decreased the number of health problems. Air-conditioning increased dependence upon it, limited passive adaptation and only people living in homes with whole-house air-conditioning had less health problems during heatwaves. Tenants and respondents with pre-existing health conditions were the most vulnerable, particularly as those with health conditions were not aware of their vulnerability. The introduction of an Energy Performance Certificate is proposed and discussed as an effective incentive to increase the heat stress resistance of and the general knowledge about the built environment. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Phased Retrofits in Existing Homes in Florida Phase II: Shallow Plus Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sutherland, K.; Parker, D.; Martin, E.

    Originally published in February 2016, this revision contains an added section called 'Evaluation of Complete Central System Replacement with Inverter-Driven Heat Pump,' which presents the designs and energy savings evaluations of two different schemes wherein inverter-driven systems replaced a home’s existing central system. Analyses for three additional retrofit measures were bolstered by longer-term data; these are described in the sections on supplemental mini-split heat pumps (MSHPs), smart thermostats, and heat pump clothes dryers. The sections on supplemental MSHPs and smart thermostats were also enhanced with larger sample sizes and projections of weather-normalized annual energy savings. Finally, peak system hour energymore » demand-reduction predictions are provided for all retrofit measures where meaningful impacts could be drawn.« less

  4. Environmental and Sustainable Technology Evaluations (ESTE): Verification of Microbial Resistant Building Materials

    EPA Science Inventory

    This is an ESTE project summary brief. Many of the finished interior surfaces of homes and buildings are composed of materials that are prone to mold growth. These surfaces include gypsum board, wood flooring, insulation, and components of the heating and air conditioning system...

  5. Phased Retrofits in Existing Homes in Florida Phase II: Shallow Plus Retrofits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sutherland, K.; Parker, D.; Martin, E.

    The BAPIRC team and Florida Power and Light (FPL) electric utility pursued a pilot phased energy-efficiency retrofit program in Florida by creating detailed data on the energy and economic performance of two levels of retrofit - simple and deep. For this Phased Deep Retrofit (PDR) project, a total of 56 homes spread across the utility partner's territory in east central Florida, southeast Florida, and southwest Florida were instrumented between August 2012 and January 2013, and received simple pass-through retrofit measures during the period of March 2013 - June 2013. Ten of these homes received a deeper package of retrofits duringmore » August 2013 - December 2013. A full account of Phase I of this project, including detailed home details and characterization, is found in Parker et al, 2015 (currently in draft). Phase II of this project, which is the focus of this report, applied the following additional retrofit measures to select homes that received a shallow retrofit in Phase I: a) Supplemental mini-split heat pump (MSHP) (6 homes); b) Ducted and space coupled Heat Pump Water Heater (8 homes); c) Exterior insulation finish system (EIFS) (1 homes); d) Window retrofit (3 homes); e) Smart thermostat (21 homes: 19 NESTs; 2 Lyrics); f) Heat pump clothes dryer (8 homes); g) Variable speed pool pump (5 homes).« less

  6. Home is where the hearth is: grant recipients' views of England's home energy efficiency scheme (Warm Front).

    PubMed

    Gilbertson, Jan; Stevens, Maryjane; Stiell, Bernadette; Thorogood, Nicki

    2006-08-01

    This paper reports the results of research carried out as part of the national health impact evaluation of the Warm Front Scheme, a government initiative aimed at alleviating fuel poverty in England. Semi-structured interviews were carried out in a purposive sample of 49 households which received home energy improvements under the Scheme from five urban areas (Birmingham, Liverpool, Manchester, Newcastle, Southampton). Each household had received installation, replacement or refurbishment of the heating system and, in some cases, also insulation of the cavity wall or loft or both, and draught-proofing measures. Most householders reported improved and more controllable warmth and hot water. Many also reported perceptions of improved physical health and comfort, especially of mental health and emotional well-being and, in several cases, the easing of symptoms of chronic illness. There were reports of improved family relations, an expansion of the domestic space used during cold months, greater use of kitchens and improved nutrition, increased privacy, improved social interaction, and an increase in comfort and atmosphere within the home. Greater warmth and comfort also enhanced emotional security, and recipients were more content and at ease in their homes. However there was little evidence of substantially lower heating bills. These results provide evidence that Warm Front home energy improvements are accompanied by appreciable benefits in terms of use of living space, comfort and quality of life, physical and mental well-being, although there is only limited evidence of change in health behaviour.

  7. In the Hot Seat--Analyzing Your Heating Options

    ERIC Educational Resources Information Center

    Palliser, Janna

    2011-01-01

    When winter rolls around, keeping yourself and your home warm is of the utmost importance. Heating your home seems like a simple subject to tackle, but there are many heating systems available, requiring different fuels, installations, and costs. The various fuel types and their environmental footprints will be the focus of this month's column.…

  8. Impact of improved insulation and heating on mortality risk of older cohort members with prior cardiovascular or respiratory hospitalisations

    PubMed Central

    Keall, Michael; Telfar-Barnard, Lucy; Grimes, Arthur; Howden-Chapman, Philippa

    2017-01-01

    Objectives We carried out an evaluation of a large-scale New Zealand retrofit programme using administrative data that provided the statistical power to assess the effect of insulation and/or heating retrofits on cardiovascular and respiratory-related mortality in people aged 65 and over with prior respiratory or circulatory hospitalisations. Design Quasi-experimental cohort study based on administrative data. Setting New Zealand. Participants From a larger study cohort of over 900 000 people, we selected two subcohorts: 3287 people who were aged 65 and over and had experienced pretreatment period cardiovascular-related hospitalisation (ICD-10 chapter 9), and 1561 people aged 65 and over who had experienced pretreatment respiratory-related hospitalisation (ICD-10 chapter 10). Interventions Treatment group individuals lived in a home that received insulation and/or heating retrofits under the Warm Up New Zealand: Heat Smart programme. Control group individuals lived in a home that was matched to a treatment home based on physical characteristics and location. Primary and secondary outcome measures HR for all-cause mortality for treatment with insulation, heating, or insulation and heating relative to control group. Results People with pretreatment circulatory hospitalisation who occupied a household that received only insulation had an HR for all-cause mortality of 0.673 (95% CI 0.535 to 0.847) (p<0.001) relative to control group members. Individuals with a pretreatment respiratory hospitalisation who occupied a household that received only an insulation retrofit had an HR for all-cause mortality of 0.830 (95% CI 0.655 to 1.051) (p=0.122) relative to control group members. There was no evidence of an additional benefit from receiving heating. Conclusions We interpret the hazard rate observed for cardiovascular subcohort individuals who received insulation as evidence of a protective effect, reducing the risk of mortality for vulnerable older adults. There is suggestive evidence of a protective effect of insulation for the respiratory subcohort. PMID:29138207

  9. Building America Case Study: The Impact of Thermostat Placement in Low-Load Homes in Sunny Climates, Denver, Colorado

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Modern, energy-efficient homes conforming to the Zero Energy Ready Home standard face the challenge of meeting high customer expectations for comfort. Traditional heating, ventilation, and air conditioning (HVAC) sizing and control strategies may be insufficient to adequately condition each zone due to unique load patterns in each room caused by a number of factors. These factors include solar heat gains, occupant-related gains, and gains associated with appliances and electronics. Because of shrinking shell loads, these intermittent factors are having an increasingly significant impact on the thermal load in each zone. Consequently, occupant comfort can be compromised. To evaluate the impactmore » of climate and house geometry, as well as HVAC system and control strategies on comfort conditions, IBACOS analyzed the results of 99 TRNSYS multiple-zone simulations. The results of this analysis indicate that for simple-geometry and single-story plans, a single zone and thermostat can adequately condition the entire house. Demanding house geometry and houses with multiple stories require the consideration of multiple thermostats and multiple zones.« less

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    A new generation of central, ducted variable-capacity heat pump systems has come on the market, promising very high cooling and heating efficiency. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they vary their cooling and heating output over a wide range (approximately 40 to 118% of nominal full capacity); thus, staying 'on' for 60% to 100% more hours per day compared to fixed-capacity systems. Current Phase 4 experiments in an instrumented lab home with simulated occupancy evaluate the impact of duct R-value enhancement on the overall operating efficiency of the variable-capacity systemmore » compared to the fixed-capacity system.« less

  11. Primary-Grade Students' Knowledge and Thinking about the Supply of Utilities (Water, Heat, and Light) to Modern Homes.

    ERIC Educational Resources Information Center

    Brophy, Jere; Alleman, Janet

    2003-01-01

    This interview study gathered information about the prior knowledge and thinking of kindergarten to third- graders regarding the supply of water, heat, and light to modern homes. Findings indicated that students possessed only limited and spotty knowledge about utilities in modern homes. Within general trends, there was evidence of growth in…

  12. Efficacy of interventions targeting household air pollution from residential wood stoves.

    PubMed

    Ward, Tony J; Semmens, Erin O; Weiler, Emily; Harrar, Solomon; Noonan, Curtis W

    2017-01-01

    Wood is commonly used for residential heating, but there are limited evidence-based interventions for reducing wood smoke exposures in the indoor environment. The Asthma Randomized Trial of Indoor Wood Smoke (ARTIS) study was designed to assess the efficacy of residential interventions to reduce indoor PM exposure from wood stoves. As part of a three-arm randomized placebo-controlled trial, two household-level interventions were evaluated: wood stove changeouts and air filtration units. Exposure outcomes included indoor measures such as continuous PM 2.5 , particle counts, and carbon monoxide. Median indoor PM 2.5 concentration was 17.5 μg/m 3 in wood-burning homes prior to interventions. No significant reductions in PM 2.5 concentrations were observed in the 40 homes receiving the placebo filter intervention. Sixteen homes received the wood stove changeout and showed no significant changes in PM 2.5 or particle counts. PM 2.5 concentrations were reduced by 68% in the filter intervention homes. Relative to placebo, air filtration unit homes had an overall PM 2.5 reduction of 63% (95% CI: 47-75%). Relative to the wood stove changeout, the filtration unit intervention was more efficacious and less expensive, yet compliance issues indicated a need for the evaluation of additional strategies for improving indoor air quality in homes using wood stoves.

  13. DOE Zero Energy Ready Home Case Study: BPC Green Builders — Trolle Residence, Danbury, CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2014-09-01

    The builder of this 1,650-ft2 cabin won a Custom Home honor in the 2014 Housing Innovations Awards. The home meets Passive House Standards with 5.5-in. of foil-faced polysiocyanurate foam boards lining the outside walls, R-55 of rigid EPS foam under the slab, R-86 of blown cellulose in the attic, triple-pane windows, and a single ductless heat pump to heat and cool the entire home.

  14. New Whole-House Solutions Case Study: Performance and Costs of Ductless Heat Pumps in Marine Climate High-Performance Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2016-02-24

    The Woods is a sustainable community built by Habitat for Humanity in 2013. This community comprises 30 homes that are high-performance and energy-efficient. With support from Tacoma Public Utilities and the Bonneville Power Administration, the BA-PIRC team is researching the energy performance of these homes and the ductless heat pumps they employ.

  15. Operating and maintaining your heat recovery ventilator (HRV) -- Revised edition. Home heating and cooling series, Number 8

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Heat recovery ventilators (HRVs) differ from other mechanical ventilation devices by their ability to exchange heat between supply and exhaust air streams, which reduces the cost of heating or cooling fresh air. This booklet discusses the need for mechanical ventilation in conventional and energy-efficient homes, an explains the components of a HRV system, how to operate and maintain the system, and how to solve operating problems. A maintenance chart and schedule and a HRV troubleshooting guide are included.

  16. Development of an Operation Control System for Photovoltaics and Electric Storage Heaters for Houses Based on Information in Weather Forecasts

    NASA Astrophysics Data System (ADS)

    Obara, Shin'ya

    An all-electric home using an electric storage heater with safety and cleaning is expanded. However, the general electric storage heater leads to an unpleasant room temperature and energy loss by the overs and shorts of the amount of heat radiation when the climate condition changes greatly. Consequently, the operation of the electric storage heater introduced into an all-electric home, a storage type electric water heater, and photovoltaics was planned using weather forecast information distributed by a communication line. The comfortable evaluation (the difference between a room-temperature target and a room-temperature result) when the proposed system was employed based on the operation planning, purchase electric energy, and capacity of photovoltaics was investigated. As a result, comfortable heating operation was realized by using weather forecast data; furthermore, it is expected that the purchase cost of the commercial power in daytime can be reduced by introducing photovoltaics. Moreover, when the capacity of the photovoltaics was increased, the surplus power was stored in the electric storage heater, but an extremely unpleasant room temperature was not shown in the investigation ranges of this paper. By obtaining weather information from the forecast of the day from an external service using a communication line, the heating system of the all-electric home with low energy loss and comfort temperature is realizable.

  17. Where Does RECS Square Footage Data Come From?

    EIA Publications

    2012-01-01

    The size of a home is a fixed characteristic strongly associated with the amount of energy consumed within it, particularly for space heating, air conditioning, lighting, and other appliances. As a part of the Residential Energy Consumption Survey (RECS), trained interviewers measure the square footage of each housing unit. RECS square footage data allow comparison of homes with varying characteristics. In-person measurements are vital because many alternate data sources, including property tax records, real estate listings, and, respondent estimates use varying definitions and under-estimate square footage as defined for the purposes of evaluating residential energy consumption.

  18. Campbell Creek Research Homes: FY2013 Annual Performance Report OCT.1, 2012 SEP. 30, 2013

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jackson, Roderick K; Boudreaux, Philip R; Munk, Jeffrey D

    1.INTRODUCTION AND PROJECT OVERVIEW The Campbell Creek project is funded and managed by the Tennessee Valley Authority (TVA) Technology Innovation, Energy Efficiency, Power Delivery and Utilization Office. Technical support is provided under contract by the Oak Ridge National Laboratory (ORNL) and the Electric Power Research Institute (EPRI). The project was designed to determine the relative energy efficiency of typical new home construction, of retrofitting of existing homes, and of high-performance new homes built from the ground up for energy efficiency. This project was designed to compare three houses that represent current construction practices: a base case (Builder House CC1); amore » modified house that could represent a major energy-efficient retrofit (Retrofit House CC2); and a house constructed from the ground up to be a high-performance home (High Performance House CC3). To enable a valid comparison, it was necessary to simulate occupancy in all three houses and extensively monitor the structural components and the energy usage by component. In October 2013, the base case was also modified by replacing the builder-grade heating, ventilation, and air-conditioning (HVAC) system with a high-efficiency variable-speed unit. All three houses are two-story, slab-on-grade, framed construction. CC1 and CC2 are approximately 2,400 ft2. CC3 has a pantry option, used primarily as a mechanical equipment room, that adds approximately 100 ft2. All three houses are all-electric (with the exception of a gas log fireplace that is not used during the testing) and use air-source heat pumps for heating and cooling. The three homes are located in Knoxville in the Campbell Creek Subdivision. CC1 and CC2 are next door to each other with a south-facing orientation; CC3 has a north-facing orientation and is located across the street and a couple of houses down. The energy data collected will be used to determine the benefits of retrofit packages and high-performance new home packages. There are more than 300 channels of continuous energy performance and thermal comfort data collection in the houses (100 for each house). The data will be used to evaluate the impact of energy-efficiency upgrades on the envelope, mechanical equipment, and demand-response options. Each retrofit will be evaluated incrementally, by both short-term measurements and computer modeling, using a calibrated model. This report is intended to document the comprehensive testing, data analysis, research, and findings within the October 2012 through September 2013 (FY 2013) timeframe at the Campbell Creek research houses. The following sections will provide an in-depth assessment of the technology progression in each of the three research houses. A detailed assessment and evaluation of the energy performance of technologies tested will also be provided. Finally, lessons learned and concluding remarks will be highlighted.« less

  19. Factors of subjective heat stress of urban citizens in contexts of everyday life

    NASA Astrophysics Data System (ADS)

    Kunz-Plapp, Tina; Hackenbruch, Julia; Schipper, Janus Willem

    2016-04-01

    Heat waves and the consequent heat stress of urban populations have a growing relevance in urban risk management and strategies of urban adaptation to climate change. In this context, social science studies on subjective experiencing of heat as stress by urban citizens are a new emerging field. To contribute to the understanding of self-reported subjective heat stress and its major determinants in a daily life perspective, we conducted a questionnaire survey with 323 respondents in Karlsruhe, Germany, after heat waves in July and August 2013. Statistical data analysis showed that subjective heat stress is an issue permeating everyday activities. Subjective heat stress at home was lower than at work and in general. Subjective heat stress in general, at home, and at work was determined by the health impairments experienced during the heat and the feeling of being helplessly exposed to the heat. For subjective heat stress at home, characteristics of the residential building and the built environment additionally played a role. Although the rate of implemented coping measures was rather high, coping measures showed no uniform effect for the subjective heat stress. We conclude that in terms of urban adaptation strategies, further research is needed to understand how various processes of daily social (work) life enable or limit individual coping and that communication strategies are important for building capacities to better cope with future heat waves.

  20. Living with an autonomous spatiotemporal home heating system: Exploration of the user experiences (UX) through a longitudinal technology intervention-based mixed-methods approach.

    PubMed

    Kruusimagi, Martin; Sharples, Sarah; Robinson, Darren

    2017-11-01

    Rising energy demands place pressure on domestic energy consumption, but savings can be delivered through home automation and engaging users with their heating and energy behaviours. The aim of this paper is to explore user experiences (UX) of living with an automated heating system regarding experiences of control, understanding of the system, emerging thermal behaviours, and interactions with the system as this area is not sufficiently researched in the existing homes setting through extended deployment. We present a longitudinal deployment of a quasi-autonomous spatiotemporal home heating system in three homes. Users were provided with a smartphone control application linked to a self-learning heating algorithm. Rich qualitative and quantitative data presented here enabled a holistic exploration of UX. The paper's contribution focuses on highlighting key aspects of UX living with an automated heating systems including (i) adoption of the control interface into the social context, (ii) how users' vigilance in maintaining preferred conditions prevailed as a better indicator of system over-ride than gross deviation from thermal comfort, (iii) limited but motivated proactivity in system-initiated communications as best strategy for soliciting user feedback when inference fails, and (iv) two main motivations for interacting with the interface - managing irregularities when absent from the house and maintaining immediate comfort, latter compromising of a checking behaviour that can transit to a system state alteration behaviour depending on mismatches. We conclude by highlighting the complex socio-technical context in which thermal decisions are made in a situated action manner, and by calling for a more holistic, UX-focused approach in the design of automated home systems involving user experiences. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. FIELD PERFORMANCE OF ADVANCED TECHNOLOGY WOODSTOVES IN GLEN FALLS, NY, 1988-89 - VOLUME I

    EPA Science Inventory

    The report gives results of an evaluation of particulate emission trends for three models of catalytic and two models of non- catalytic woodstoves under in-home burning conditions during the 1988-89 heating season in Glens Falls, NY. he results (averaging 9.4 g/h and 9.4 g/kg) sh...

  2. FIELD PERFORMANCE OF ADVANCED TECHNOLOGY WOODSTOVES IN GLEN FALLS, NY, 1988-89 - VOLUME II - TECHNICAL APPENDICES

    EPA Science Inventory

    The report gives results of an evaluation of particulate emission trends for three models of catalytic and two models of non- catalytic woodstoves under "in-home" burning conditions during the 1988-89 heating season in Glens Falls, NY. The results (averaging 9.4 g/h and 9.4 g/kg...

  3. Heat protection behaviour in the UK: results of an online survey after the 2013 heatwave.

    PubMed

    Khare, Swarna; Hajat, Shakoor; Kovats, Sari; Lefevre, Carmen E; de Bruin, Wändi Bruine; Dessai, Suraje; Bone, Angie

    2015-09-10

    The Heatwave Plan for England provides guidance for personal and home protection measures during heatwaves. Although studies in the USA, Australia and Europe have surveyed heat-related behaviours during heatwaves, few have been conducted in the UK. This study assesses personal and housing (at-home) behaviour and housing characteristics of the UK population during the 2013 heatwave. This paper analyses data from 1497 respondents of an online survey on heat protection measures and behaviour. Participants were asked questions about their behaviour during the 2013 heatwave, the characteristics of their current housing as well as about any negative health outcomes experienced due to the hot weather. We used multinomial logit regression to analyse personal and home heat protection behaviour and logistic regression to analyse characteristics of participants' current home (installed air conditioner, curtains etc.). We stratified the outcomes by age, sex, ethnicity, income, education and regional location. In 2013, for all heat-related illness (except tiredness), a higher proportion of those in the younger age groups reported symptoms compared with those in the older age groups. Women, higher income groups and those with higher education levels were found to be more likely to report always/often taking personal heat protective measures. The elderly were less likely to take some personal and home protective measures but were more likely to live in insulated homes and open windows at night to keep their home cool. Our study has found a high level of awareness of the actions to take during heatwaves in the UK, and has identified important demographic indicators of sections of the UK population that might benefit from additional or more targeted information. The health agencies should attempt to provide better information about heatwaves to those vulnerable (elderly, those at risk living in London, low income earners) or identify any barriers that might be preventing them from undertaking protective behaviour.

  4. Building America Case Study: Impact of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps, Cocoa, Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    C. Withers, J. Cummings, B. Nigusse, E. Martin

    A new generation of central, ducted variable-capacity heat pump systems has come on the market, promising very high cooling and heating efficiency. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they vary their cooling and heating output over a wide range (approximately 40 to 118% of nominal full capacity); thus, staying 'on' for 60% to 100% more hours per day compared to fixed-capacity systems. Current Phase 4 experiments in an instrumented lab home with simulated occupancy evaluate the impact of duct R-value enhancement on the overall operating efficiency of the variable-capacity systemmore » compared to the fixed-capacity system.« less

  5. Geothermal heat for Presbyterian Intercommunity Hospital and Klamath County Nursing Home

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howard, R.L.; Hubbard, K.; Rosecrans, D.

    The geology and hydrology of the Klamath Falls area is discussed briefly. The geothermal heating system which serves the Presbyterian Intercommunity Hospital and the Klamath County Nursing Home is shown in photographs and schematic drawing. The system consists basically of a well, settling tank, various heat exchangers, pumps, piping, and controls to move the water. From the heat exchangers system water is pumped to the terminal units, where it is used for space heating, domestic hot water, and a glycol snow melting system. The operation of the various parts of the system is described. (MHR)

  6. Economic feasibility study of residential and commercial heating using existing water supply systems. Final report June 1, 1979 - August 15, 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pitts, Donald R.; Looper, Marshall G.

    1979-08-15

    A study of the use of a low-to-moderate temperature hydrothermal resource for space heating a 140-home residential community has been undertake. The approach centers on use of the existing culinary/potable water supply system to supply heated water to the homes, the culinary water being heated at a single pumping station and then distributed throughout the community through uninsulated, buried water mains. The heated potable water is pumped through individual house water-to-air heat exchangers using sealed, magnetic-drive house pumps and returned to the street distribution lines. These house heat exchangers are either add-on, wall mounted, convective heating units or coils addedmore » to existing forced air heating systems.« less

  7. DOE Zero Energy Ready Home Case Study: Greenhill Contracting, Inc., Hickory Ridge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pacific Northwest National Laboratory

    Greenhill Contracting built this 3,912-ft2 house in Gardiner, New York, to the high-performance criteria of the DOE Zero Energy Ready Home (ZERH) program. A highly efficient air-source heat pump heats and cools the home’s interior, while the roof-mounted photovoltaic system offsets electricity usage to cut energy bills to nearly zero. Many months the home owners see a credit on their utility bill.

  8. Home retrofitting for energy conservation and solar considerations

    NASA Astrophysics Data System (ADS)

    1981-10-01

    A manual which explains both the key concepts behind the need for and the home energy efficiency improvement is reviewed. A comprehensive picture of how home energy use is effected by the inhabitants and by the structure itself is presented. The manual explains: looking at energy, how the heat transfer occurs between houses and humans, energy audits and how to use them, energy conservation actions to do now to reduce energy use. Schemes to reduce infiltration, how to increase insulation, and what to do with windows and doors, heating and heat distribution systems, and water heaters are included. Solar energy options are explained, as well as financing and tax credits.

  9. Field evaluation and assessment of thermal energy storage for residential space heating

    NASA Astrophysics Data System (ADS)

    Hersh, H. N.

    1982-02-01

    A data base was developed based on two heating seasons and 45 test and 30 control homes in Maine and Vermont. Based on first analysis of monitored temperatures and electrical energy used for space heating, fuel bills and reports of users and utilities, the technical performance of TES ceramic and hydronic systems is deemed to be technically satisfactory and there is a high degree of customer acceptance and positive attitudes towards TES. Analysis of house data shows a high degree of variability in electric heat energy demand for a given degree-day. An analysis is underway to investigate relative differences in the efficiency of electricity utilization of storage and direct heating devices. The much higher price of storge systems relative to direct systems is an impediment to market penetration. A changing picture of rate structures may encourage direct systems at the expense of storage systems.

  10. Impact of improved insulation and heating on mortality risk of older cohort members with prior cardiovascular or respiratory hospitalisations.

    PubMed

    Preval, Nicholas; Keall, Michael; Telfar-Barnard, Lucy; Grimes, Arthur; Howden-Chapman, Philippa

    2017-11-14

    We carried out an evaluation of a large-scale New Zealand retrofit programme using administrative data that provided the statistical power to assess the effect of insulation and/or heating retrofits on cardiovascular and respiratory-related mortality in people aged 65 and over with prior respiratory or circulatory hospitalisations. Quasi-experimental cohort study based on administrative data. New Zealand. From a larger study cohort of over 900 000 people, we selected two subcohorts: 3287 people who were aged 65 and over and had experienced pretreatment period cardiovascular-related hospitalisation (ICD-10 chapter 9), and 1561 people aged 65 and over who had experienced pretreatment respiratory-related hospitalisation (ICD-10 chapter 10). Treatment group individuals lived in a home that received insulation and/or heating retrofits under the Warm Up New Zealand: Heat Smart programme. Control group individuals lived in a home that was matched to a treatment home based on physical characteristics and location. HR for all-cause mortality for treatment with insulation, heating, or insulation and heating relative to control group. People with pretreatment circulatory hospitalisation who occupied a household that received only insulation had an HR for all-cause mortality of 0.673 (95% CI 0.535 to 0.847) (p<0.001) relative to control group members. Individuals with a pretreatment respiratory hospitalisation who occupied a household that received only an insulation retrofit had an HR for all-cause mortality of 0.830 (95% CI 0.655 to 1.051) (p=0.122) relative to control group members. There was no evidence of an additional benefit from receiving heating. We interpret the hazard rate observed for cardiovascular subcohort individuals who received insulation as evidence of a protective effect, reducing the risk of mortality for vulnerable older adults. There is suggestive evidence of a protective effect of insulation for the respiratory subcohort. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Solar Energy: Home Heating.

    ERIC Educational Resources Information Center

    Knapp, Henry H., III

    This module on home heating is one of six in a series intended for use as supplements to currently available materials on solar energy and energy conservation. Together with the recommended texts and references (sources are identified), these modules provide an effective introduction to energy conservation and solar energy technologies. The module…

  12. Building America Best Practices Series, Volume 6: High-Performance Home Technologies: Solar Thermal & Photovoltaic Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baechler, Michael C.; Gilbride, Theresa L.; Ruiz, Kathleen A.

    This guide is was written by PNNL for the US Department of Energy's Building America program to provide information for residential production builders interested in building near zero energy homes. The guide provides indepth descriptions of various roof-top photovoltaic power generating systems for homes. The guide also provides extensive information on various designs of solar thermal water heating systems for homes. The guide also provides construction company owners and managers with an understanding of how solar technologies can be added to their homes in a way that is cost effective, practical, and marketable. Twelve case studies provide examples of productionmore » builders across the United States who are building energy-efficient homes with photovoltaic or solar water heating systems.« less

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    This case study describes a DOE Zero Energy Ready home in Vassalboro, Maine, that scored HERS 35 without PV and HERS 11 with PV. This 1,200 ft2 home has 10.5-inch-thick double-walls with 3 layers of mineral wool batt insulation, an R-20 insulated slab, R-70 cellulose in the attic, extensive air sealing, a mini-split heat pump, an heat recovery ventilator, solar water heating, LED lighting, 3.9 kWh PV, and triple-pane windows.

  14. Passive solar nursing home for Northern Kentucky

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, J.G.; Ward, J.D.

    This project is a 32-bed nursing home designed as an addition to an existing facility. Passive solar strategies included direct gain room windows and clerestories which admit light to phase change salt pouches in the ceilings of patient rooms. Corridors are skykighted; and the heating, ventilating, and conditioning system is comprised of water-source heat pumps and a 5000 gallon storage tank in conjunction with an air to air heat recovery wheel.

  15. Mortality during a Large-Scale Heat Wave by Place, Demographic Group, Internal and External Causes of Death, and Building Climate Zone.

    PubMed

    Joe, Lauren; Hoshiko, Sumi; Dobraca, Dina; Jackson, Rebecca; Smorodinsky, Svetlana; Smith, Daniel; Harnly, Martha

    2016-03-09

    Mortality increases during periods of elevated heat. Identification of vulnerable subgroups by demographics, causes of death, and geographic regions, including deaths occurring at home, is needed to inform public health prevention efforts. We calculated mortality relative risks (RRs) and excess deaths associated with a large-scale California heat wave in 2006, comparing deaths during the heat wave with reference days. For total (all-place) and at-home mortality, we examined risks by demographic factors, internal and external causes of death, and building climate zones. During the heat wave, 582 excess deaths occurred, a 5% increase over expected (RR = 1.05, 95% confidence interval (CI) 1.03-1.08). Sixty-six percent of excess deaths were at home (RR = 1.12, CI 1.07-1.16). Total mortality risk was higher among those aged 35-44 years than ≥ 65, and among Hispanics than whites. Deaths from external causes increased more sharply (RR = 1.18, CI 1.10-1.27) than from internal causes (RR = 1.04, CI 1.02-1.07). Geographically, risk varied by building climate zone; the highest risks of at-home death occurred in the northernmost coastal zone (RR = 1.58, CI 1.01-2.48) and the southernmost zone of California's Central Valley (RR = 1.43, CI 1.21-1.68). Heat wave mortality risk varied across subpopulations, and some patterns of vulnerability differed from those previously identified. Public health efforts should also address at-home mortality, non-elderly adults, external causes, and at-risk geographic regions.

  16. Aerial thermal scanner data for monitoring rooftop temperatures

    NASA Technical Reports Server (NTRS)

    Bjorkland, J.; Schmer, F. A.; Isakson, R. E.

    1975-01-01

    Four Nebraska communities and one South Dakota community were surveyed. Thermal scanner data were converted to a film format and the resultant imagery was successfully employed to monitor rooftop temperatures. The program places emphasis on heat losses resulting from inadequate home insulation, offers CENGAS customers the opportunity to observe a thermogram of their rooftop, and assists homeowners in evaluating insulation needs.

  17. Simplified Space Conditioning in Low-Load Homes: Results from Pittsburgh, Pennsylvania, New Construction Unoccupied Test House

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poerschke, Andrew; Stecher, Dave

    2014-06-01

    Field testing was performed in a new construction unoccupied test house in Pittsburgh, PA. Four air-based heating, ventilation, and air conditioning distribution systems—a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, a system with transfer fans to the bedrooms, and a system with no ductwork to the bedrooms—were evaluated during heating, cooling, and midseason conditions. The relative ability of each system was assessed with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability, respectively.

  18. Simplified Space Conditioning in Low-Load Homes: Results from Pittsburgh, Pennsylvania, New Construction Unoccupied Test House

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poerschke, A.; Stecher, D.

    2014-06-01

    Field testing was performed in a new construction unoccupied test house in Pittsburgh, Pennsylvania. Four air-based heating, ventilation, and air conditioning distribution systems--a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, a system with transfer fans to the bedrooms, and a system with no ductwork to the bedrooms--were evaluated during heating, cooling, and midseason conditions. The relative ability of each system was assessed with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability, respectively.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, W.N.

    This report summarizes measured performance of residential geothermal heat pumps (GHP`s) that were installed in family housing units at Ft. Hood, Texas and at Selfridge Air National Guard base in Michigan. These units were built as part of a joint Department of Defense/Department of Energy program to evaluate the energy savings potential of GHP`s installed at military facilities. At the Ft. Hood site, the GHP performance was compared to conventional forced air electric air conditioning and natural gas heating. At Selfridge, the homes under test were originally equipped with electric baseboard heat and no air conditioning. Installation of the GHPmore » systems at both sites was straightforward but more problems and costs were incurred at Selfridge because of the need to install ductwork in the homes. The GHP`s at both sites produced impressive energy savings. These savings approached 40% for most of the homes tested. The low cost of energy on these bases relative to the incremental cost of the GHP conversions precludes rapid payback of the GHP`s from energy savings alone. Estimates based on simple payback (no inflation and no interest on capital) indicated payback times from 15 to 20 years at both sites. These payback times may be reduced by considering the additional savings possible due to reduced maintenance costs. Results are summarized in terms of 15 minute, hourly, monthly, and annual performance parameters. The results indicate that all the systems were working properly but several design shortcomings were identified. Recommendations are made for improvements in future installations at both sites.« less

  20. Organic absorption gas-fired residential heat pump

    NASA Astrophysics Data System (ADS)

    Murphy, K. P.

    The development program of a system utilizing a new absorption pair, R133a (CF3CH2Cl) as the refigerant, and ETFE (ethyletra-hydrofurfury lether) as the absorber fluid, is described. A diagram of the basic configuration is shown. The cooling mode and the heating mode are discussed. Six units of an early hardware design were constructed and tested. Two of these units were placed in home heating service during the 1980-81 season. A market evaluation of the business potential of the absorption system was made, identifying location and size of the likely market for such a system. A performance simulation analysis was performed for seven cities in the US. From these, general characteristics of the areas having the greatest performance benefits were established.

  1. DOE Zero Energy Ready Home Case Study: John Hubert Associates — EXIT-0 House, North Cape May, NJ

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    This house is the first DOE Zero Energy Ready Home for this builder and won a Custom Builder award in the 2014 Housing Innovation Awards. The 1,871-ft2 home features advanced-framed above-grade walls with R-21 fiberglass batt plus an R-3.6-insulated coated OSB sheathing, R-18 rigid-foam-insulated crawlspace walls, solar water heating, a high-efficiency heat pump, an HRV, and mostly LED lighting.

  2. Indoor Air Quality in Central Appalachia Homes Impacted by Wood and Coal Use

    PubMed Central

    Paulin, Laura M.; Williams, D’Ann; Oberweiser, Charles; Diette, Gregory B.; Breysse, Patrick N.; McCormack, Meredith M.; Matsui, Elizabeth C.; Peng, Roger; Metts, Tricia A.; Hansel, Nadia N.

    2016-01-01

    Though the high prevalence of biomass fuel use in the developing world is widely known, the use of burning biomass for cooking and heating in the developed world is under-recognized. Combustion materials including coal and wood are also used for heating in some areas of the United States. We conducted a pilot study to assess the feasibility of conducting indoor environmental monitoring in rural Appalachia. We sought to explore the type of biomass being used for home heating and its impact upon indoor air quality in non-heating and heating seasons. Residential indoor air monitoring for particulate matter (PM) and nitrogen dioxide (NO2) was conducted in Lee County, Virginia. Homes had evidence of poor indoor air quality with high concentrations of indoor PM and a large burden of cigarette smoking. Further characterization of indoor combustion material use in this region to determine the health impacts associated with such exposures is warranted. PMID:27738549

  3. Effectiveness of inactivation of foodborne pathogens during simulated home pan frying of steak, hamburger or meat strips.

    PubMed

    Lahou, Evy; Wang, Xiang; De Boeck, Elien; Verguldt, Elien; Geeraerd, Annemie; Devlieghere, Frank; Uyttendaele, Mieke

    2015-08-03

    In order to evaluate the effect of simulated home pan frying of raw meat and meat preparations of different animal species on the thermal inactivation of pathogens, the heat resistance (D-value) of three strains of Campylobacter jejuni, Escherichia coli O157:H7, Salmonella spp., Listeria monocytogenes and two strains of generic E. coli was validated in BHI and adjusted BHI (i.e. pH5.6 and 1.5% NaCl) at 60°C. The D-values were obtained of the linear phase of the survivor curves created in GInaFiT, a freeware tool to fit models to experimental data. The obtained D-values corresponded to those previously published in literature and confirmed L. monocytogenes to be the most heat resistant pathogen among them. Heat treatment in adjusted BHI significantly increased heat-resistance of E. coli O157:H7 and generic E. coli. Subsequently, the thermal inactivation of L. monocytogenes, Salmonella spp., C. jejuni and E. coli O157:H7 was evaluated using a standardized procedure simulating commonly used home pan frying of various types of meat including steaks or filets, hamburgers and meat strips from various animal species such as pork, beef, chicken, lamb and some turkey, horse, kangaroo and crocodile meat. Corresponding F70-values were calculated based upon measured core time/temperature profiles. It was noted that a core temperature of 70 °C was not always achieved and, moreover, a heat treatment equivalent to 2 min at 70 °C was also not always obtained. This was in particular noted in hamburgers although the meat was visually judged well done. On several occasions, residual survivors of the initial inoculated (4 logCFU/g) food borne pathogens could be recovered either by enumeration (limit of detection 1 logCFU/g) or by the presence/absence testing per 25 g. Pan frying of hamburgers yielded the highest number of surviving pathogenic bacteria (46%), followed by well-done filets and steaks (13%) and meat strips (12%). Taking only steaks (beef, horse, kangaroo, crocodile and turkey) into account, residual detection of pathogens occurred for all levels of doneness: 18% for well-done, 71% for medium and even 90% for rare steaks. Numbers of L. monocytogenes recovered after heat treatment ranged from <1 logCFU/g to 2.6 logCFU/g. Although, the prevalence of pathogens in meat might be low, and the numbers present in case of natural contamination are probably lower than the current used inoculum of 4 logCFU/g, consumers could still be exposed to surviving food borne pathogens in case of these commonly used pan frying of raw meat and meat preparations at consumer's home. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Design and Development of an Intelligent Energy Controller for Home Energy Saving in Heating/Cooling System

    NASA Astrophysics Data System (ADS)

    Abaalkhail, Rana

    Energy is consumed every day at home as we perform simple tasks, such as watching television, washing dishes and heating/cooling home spaces during season of extreme weather conditions, using appliances, or turning on lights. Most often, the energy resources used in residential systems are obtained from natural gas, coal and oil. Moreover, climate change has increased awareness of a need for expendable, energy resources. As a result, carbon dioxide emissions are increasing and creating a negative effect on our environment and on our health. In fact, growing energy demands and limited natural resource might have negative impacts on our future. Therefore, saving energy is becoming an important issue in our society and it is receiving more attention from the research community. This thesis introduces a intelligent energy controller algorithm based on software agent approach that reduce the energy consumption at home for both heating and cooling spaces by considering the user's occupancy, outdoor temperature and user's preferences as input to the system. Thus the proposed approach takes into consideration the occupant's preferred temperature, the occupied and unoccupied spaces, as well as the time spent in each area of the home. A Java based simulator has been implemented to simulate the algorithm for saving energy in heating and cooling systems. The results from the simulator are compared to the results of using HOT2000, which is Canada's leading residential energy analysis and rating software developed by CanmetENERGY's Housing, Buildings, Communities and Simulation (HBCS) group. We have calculated how much energy a home modelled will use under emulated conditions. The results showed that the implementation of the proposed energy controller algorithm can save up to 50% in energy consumption in homes dedicated to heating and cooling systems compared to the results obtained by using HOT2000.

  5. The Building America Indoor Temperature and Humidity Measurement Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Metzger, C.; Norton, Paul

    2014-02-01

    When modeling homes using simulation tools, the heating and cooling set points can have a significant impact on home energy use. Every four years, the Energy Information Administration (EIA) Residential Energy Consumption Survey (RECS) asks homeowners about their heating and cooling set points. Unfortunately, no temperature data is measured, and most of the time, the homeowner may be guessing at this number. Even one degree Fahrenheit difference in heating set point can make a 5% difference in heating energy use! So, the survey-based RECS data cannot be used as the definitive reference for the set point for the "average occupant"more » in simulations. The purpose of this document is to develop a protocol for collecting consistent data for heating/cooling set points and relative humidity so that an average set point can be determined for asset energy models in residential buildings. This document covers the decision making process for researchers to determine how many sensors should be placed in each home, where to put those sensors, and what kind of asset data should be taken while they are in the home. The authors attempted to design the protocols to maximize the value of this study and minimize the resources required to achieve that value.« less

  6. Building America Indoor Temperature and Humidity Measurement Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engebrecht-Metzger, Cheryn; Norton, Paul

    2014-02-01

    When modeling homes using simulation tools, the heating and cooling set points can have a significant impact on home energy use. Every 4 years the Energy Information Administration (EIA) Residential Energy Consumption Survey (RECS) asks homeowners about their heating and cooling set points. Unfortunately, no temperature data is measured, and most of the time, the homeowner may be guessing at this number. Even one degree Fahrenheit difference in heating set point can make a 5% difference in heating energy use! So, the survey-based RECS data cannot be used as the definitive reference for the set point for the 'average occupant'more » in simulations. The purpose of this document is to develop a protocol for collecting consistent data for heating/cooling set points and relative humidity so that an average set point can be determined for asset energy models in residential buildings. This document covers the decision making process for researchers to determine how many sensors should be placed in each home, where to put those sensors, and what kind of asset data should be taken while they are in the home. The authors attempted to design the protocols to maximize the value of this study and minimize the resources required to achieve that value.« less

  7. Mortality during a Large-Scale Heat Wave by Place, Demographic Group, Internal and External Causes of Death, and Building Climate Zone

    PubMed Central

    Joe, Lauren; Hoshiko, Sumi; Dobraca, Dina; Jackson, Rebecca; Smorodinsky, Svetlana; Smith, Daniel; Harnly, Martha

    2016-01-01

    Mortality increases during periods of elevated heat. Identification of vulnerable subgroups by demographics, causes of death, and geographic regions, including deaths occurring at home, is needed to inform public health prevention efforts. We calculated mortality relative risks (RRs) and excess deaths associated with a large-scale California heat wave in 2006, comparing deaths during the heat wave with reference days. For total (all-place) and at-home mortality, we examined risks by demographic factors, internal and external causes of death, and building climate zones. During the heat wave, 582 excess deaths occurred, a 5% increase over expected (RR = 1.05, 95% confidence interval (CI) 1.03–1.08). Sixty-six percent of excess deaths were at home (RR = 1.12, CI 1.07–1.16). Total mortality risk was higher among those aged 35–44 years than ≥65, and among Hispanics than whites. Deaths from external causes increased more sharply (RR = 1.18, CI 1.10–1.27) than from internal causes (RR = 1.04, CI 1.02–1.07). Geographically, risk varied by building climate zone; the highest risks of at-home death occurred in the northernmost coastal zone (RR = 1.58, CI 1.01–2.48) and the southernmost zone of California’s Central Valley (RR = 1.43, CI 1.21–1.68). Heat wave mortality risk varied across subpopulations, and some patterns of vulnerability differed from those previously identified. Public health efforts should also address at-home mortality, non-elderly adults, external causes, and at-risk geographic regions. PMID:27005646

  8. Economical solar-heating for homes

    NASA Technical Reports Server (NTRS)

    Allred, J. W.; Shinn, J. M., Jr.; Kirby, C. E.; Barringer, S. R.

    1977-01-01

    Do-it-yourself supplementary solar-heating system is available for purchase at approximately $2,000. Report describes design, construction, testing, and economic analysis of low-cost solar heating system.

  9. [Indoor air pollution by fine particulate matter in the homes of newborns].

    PubMed

    Barría, René Mauricio; Calvo, Mario; Pino, Paulina

    Air pollution by particulate matter (PM) is a major public health problem. In Chile, the study has focused on outdoor air and PM 10 , rather than indoor air and PM 2.5 . Because newborns and infants spend most of their time at home, it is necessary to evaluate the exposure to indoor air pollution in this susceptible population. To determine concentration of PM 2.5 in the homes of newborns and identify the emission sources of the pollutants. The PM 2.5 concentration ([PM 2.5 ]) was collected over a 24hour period in 207 households. Baseline sociodemographic information and environmental factors (heating, ventilation, smoking and house cleaning), were collected. The median [PM 2.5 ] was 107.5μg/m 3 . Family history of asthma was associated with lower [PM 2.5 ] (P=.0495). Homes without heating showed a lower median [PM 2.5 ], 58.6μg/m 3 , while those using firewood, kerosene, and electricity ranged between 112.5 and 114.9, and coal users' homes reached 162.9μg/m 3 . Wood using homes had significant differences (P=.0164) in median [PM 2.5 ] whether the stove had complete combustion (98.2μg/m 3 ) vs. incomplete (112.6μg/m 3 ), or a salamander stove (140.6μg/m 3 ). Cigarette smoking was reported in 8.7% of the households, but was not associated with the [PM 2.5 ]. Ventilation was associated with a higher median [PM 2.5 ] (120.6 vs. 99.1μg/m 3 , P=.0039). We found homes with high [PM 2.5 ]. Residential wood consumption was almost universal, and it is associated with the [PM 2.5 ]. Natural ventilation increased MP 2.5 , probably due to infiltration from outside. Copyright © 2016 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Residential energy efficiency: Progress since 1973 and future potential

    NASA Astrophysics Data System (ADS)

    Rosenfeld, Arthur H.

    1985-11-01

    Today's 85 million U.S. homes use 100 billion of fuel and electricity (1150/home). If their energy intensity (resource energy/ft2) were still frozen at 1973 levels, they would use 18% more. With well-insulated houses, need for space heat is vanishing. Superinsulated Saskatchewan homes spend annually only 270 for space heat, 150 for water heat, and 400 for appliances, yet they cost only 2000±1000 more than conventional new homes. The concept of Cost of Conserved Energy (CCE) is used to rank conservation technologies for existing and new homes and appliances, and to develop supply curves of conserved energy and a least cost scenario. Calculations are calibrated with the BECA and other data bases. By limiting investments in efficiency to those whose CCE is less than current fuel and electricity prices, the potential residential plus commercial energy use in 2000 AD drops to half of that estimated by DOE, and the number of power plants needed drops by 200. For the whole buildings sector, potential savings by 2000 are 8 Mbod (worth 50B/year), at an average CCE of 10/barrel.

  11. Solar Energy: Uses for Your Home. The CIRcular: Consumer Information Report 15.

    ERIC Educational Resources Information Center

    Bank of America NT & SA, San Francisco, CA.

    This report defines active and passive solar energy systems, describes home uses for solar energy, and offers guidelines for choosing and installing a system. Much of the information is specific to the state of California. Uses for solar energy which are presented include passive space heating, passive cooling, active space heating, household…

  12. Using Simple Circuits as Thermal Models for Your Home

    ERIC Educational Resources Information Center

    Poynor, Adele

    2014-01-01

    In 2009, President Obama proposed an initiative to decrease our country's energy consumption and dependence on fossil fuels. One key to this plan was to decrease the amount of energy used to heat and cool our homes through government incentives. The EPA estimates that the average American household spends over $1000 annually for heating and…

  13. Heat of transport of air in clay.

    PubMed

    Minkin, Leonid; Shapovalov, Alexander S

    2007-01-01

    By measuring the thermomolecular pressure difference and using principles of irreversible thermodynamics, heat of transport of air in clay and its coefficient of diffusion are found. A comparison of thermotranspiration and pressure driven gas fluxes through concrete slab in homes is examined. It is shown that thermotranspiration air/radon flow may greatly exceed diffusion (pressure driven) flow in homes.

  14. 16 CFR 460.2 - What is home insulation.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... INSULATION § 460.2 What is home insulation. Insulation is any material mainly used to slow down heat flow. It... 16 Commercial Practices 1 2012-01-01 2012-01-01 false What is home insulation. 460.2 Section 460.2..., semirigid, flexible, or loose-fill form. Home insulation is for use in old or new homes, condominiums...

  15. 16 CFR 460.2 - What is home insulation.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... INSULATION § 460.2 What is home insulation. Insulation is any material mainly used to slow down heat flow. It... 16 Commercial Practices 1 2013-01-01 2013-01-01 false What is home insulation. 460.2 Section 460.2..., semirigid, flexible, or loose-fill form. Home insulation is for use in old or new homes, condominiums...

  16. 16 CFR 460.2 - What is home insulation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... INSULATION § 460.2 What is home insulation. Insulation is any material mainly used to slow down heat flow. It... 16 Commercial Practices 1 2010-01-01 2010-01-01 false What is home insulation. 460.2 Section 460.2..., semirigid, flexible, or loose-fill form. Home insulation is for use in old or new homes, condominiums...

  17. 16 CFR 460.2 - What is home insulation.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... INSULATION § 460.2 What is home insulation. Insulation is any material mainly used to slow down heat flow. It... 16 Commercial Practices 1 2014-01-01 2014-01-01 false What is home insulation. 460.2 Section 460.2..., semirigid, flexible, or loose-fill form. Home insulation is for use in old or new homes, condominiums...

  18. 16 CFR 460.2 - What is home insulation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... INSULATION § 460.2 What is home insulation. Insulation is any material mainly used to slow down heat flow. It... 16 Commercial Practices 1 2011-01-01 2011-01-01 false What is home insulation. 460.2 Section 460.2..., semirigid, flexible, or loose-fill form. Home insulation is for use in old or new homes, condominiums...

  19. DOE Zero Energy Ready Home Case Study: Amaris Homes, Afton Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pacific Northwest National Laboratory

    Amaris Homes built this 3,734-ft2 home in Afton, Minnesota, to the performance criteria of the DOE Zero Energy Ready Home (ZERH) program. A high-efficiency gas boiler provides hot water for the zoned radiant floor system as well as for faucets and showers. A high-efficiency heat pump provides zoned cooling.

  20. A field study setup of four homes having non-ventilated and semi-conditioned sealed attics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, William A.; Boudreaux, Philip R.; Pallin, Simon B.

    During the 2015-2016 fiscal year and with financial support from the Florida Building Commission (FBC) and the Florida Roofing and Sheet Metal Contractors Association (FRSA ), the University of Florida (UF) and the Oak Ridge National Laboratory (ORNL) completed Phase I of a study that setup four residential home demonstrations in Florida climate zones CZ-1A and CZ-2A. UF and ORNL are evaluating the hygrothermal (heat and moisture flow) performance and durability of sealed attic construction where expanded foam insulation is applied directly to the underside of the roof deck. The four homes are instrumented for measuring temperature and relative humiditymore » of the indoor living space, the outdoor air and the attic air. In addition, the temperature, relative humidity and moisture content of the roof sheathing are being monitored and recorded by remotely-accessible data acquisition equipment. Here, air leakage tests on the whole house, on the sealed attic and in the HVAC ducts were conducted on all four homes.« less

  1. A field study setup of four homes having non-ventilated and semi-conditioned sealed attics

    DOE PAGES

    Miller, William A.; Boudreaux, Philip R.; Pallin, Simon B.; ...

    2016-06-01

    During the 2015-2016 fiscal year and with financial support from the Florida Building Commission (FBC) and the Florida Roofing and Sheet Metal Contractors Association (FRSA ), the University of Florida (UF) and the Oak Ridge National Laboratory (ORNL) completed Phase I of a study that setup four residential home demonstrations in Florida climate zones CZ-1A and CZ-2A. UF and ORNL are evaluating the hygrothermal (heat and moisture flow) performance and durability of sealed attic construction where expanded foam insulation is applied directly to the underside of the roof deck. The four homes are instrumented for measuring temperature and relative humiditymore » of the indoor living space, the outdoor air and the attic air. In addition, the temperature, relative humidity and moisture content of the roof sheathing are being monitored and recorded by remotely-accessible data acquisition equipment. Here, air leakage tests on the whole house, on the sealed attic and in the HVAC ducts were conducted on all four homes.« less

  2. Extreme Heat: A Prevention Guide to Promote Your Personal Health and Safety

    MedlinePlus

    ... in your office, school, or home. Related Links Climate Change- Extreme Heat Heat Stress Illness Search Heat Stress Illness Data Temperature Extremes- Climate and Health Language: English (US) Español (Spanish) File ...

  3. Mind the Gap: Summary of Window Residential Retrofit Solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petersen, Joseph M.; Cort, Katherine A.; Widder, Sarah H.

    Improving the insulation, solar heat gain, and infiltration characteristics of windows in a home has the potential to significantly improve the overall thermal performance by reducing heat transfer through the window and also by decreasing infiltration of outdoor air into the home. As approximately 43% of existing homes still have single-pane clear windows (~50 million houses) and millions of other homes have only double-pane clear windows (Cort 2013), improving window performance also presents a significant opportunity for energy savings in the residential sector. Today, various energy-saving window retrofit opportunities are available to homeowners, ranging from window coverings and storm panelsmore » to highly-insulating triple-pane R-5 window replacements. Many of these technologies have been evaluated in the field, in the “Lab Homes” at Pacific Northwest National Laboratory, and through modeling to prove their cost-effectiveness and performance in different climate regions. Recently, the Pacific Northwest’s Regional Technical Forum approved a utility measure for low- emissivity storm windows based on such data. This action represents a watershed moment for increasing the variety and prevalence of fenestration options in utility programs, especially for the low-income demographic. This paper will review various window retrofit options, the most recent field test and modeling data regarding their performance and cost-effectiveness, and discuss future rating efforts. This information is useful for utilities and energy-efficiency program managers to help effectively implement incentive measures for these technologies.« less

  4. Residential Variable-Capacity Heat Pumps Sized to Heating Loads

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Munk, Jeffrey D.; Jackson, Roderick K.; Odukomaiya, Adewale

    2014-01-01

    Variable capacity heat pumps are an emerging technology offering significant energy savings potential and improved efficiency. With conventional single-speed systems, it is important to appropriately size heat pumps for the cooling load as over-sizing would result in cycling and insufficient latent capacity required for humidity control. These appropriately sized systems are often under-sized for the heating load and require inefficient supplemental electric resistance heat to meet the heating demand. Variable capacity heat pumps address these shortcomings by providing an opportunity to intentionally size systems for the dominant heating season load without adverse effects of cycling or insufficient dehumidification in themore » cooling season. This intentionally-sized system could result in significant energy savings in the heating season, as the need for inefficient supplemental electric resistance heat is drastically reduced. This is a continuation of a study evaluating the energy consumption of variable capacity heat pumps installed in two unoccupied research homes in Farragut, a suburb of Knoxville, Tennessee. In this particular study, space conditioning systems are intentionally sized for the heating season loads to provide an opportunity to understand and evaluate the impact this would have on electric resistance heat use and dehumidification. The results and conclusions drawn through this research are valid and specific for portions of the Southeastern and Midwestern United States falling in the mixed-humid climate zone. While other regions in the U.S. do not experience this type of climate, this work provides a basis for, and can help understand the implications of other climate zones on residential space conditioning energy consumption. The data presented here will provide a framework for fine tuning residential building EnergyPlus models that are being developed.« less

  5. Magnetic field characteristics of electric bed-heating devices.

    PubMed

    Wilson, B W; Lee, G M; Yost, M G; Davis, K C; Heimbigner, T; Buschbom, R L

    1996-01-01

    Measurements of the flux density and spectra of magnetic fields (MFs) generated by several types of electric bed heaters (EBH) were made in order to characterize the MFs to which the fetus may be exposed in utero from the mother's use of these devices. Data on MPs were gathered from more than 1,300 in-home and laboratory spot measurements. In-home measurements taken at seven different positions 10 cm from the EBHs determined that the mean flux density at the estimated position of the fetus relative to the device was 0.45 microT (4.5 mG) for electric blankets and 0.20 microT (2.0 mG) for electrically heated water beds. A rate-of-change (RC) metric applied to the nighttime segment of 24 h EMDEX-C personal-dosimeter measurements, which were taken next to the bed of volunteers, yielded an approximate fourfold to sixfold higher value for electric blanket users compared to water-bed heater users. These same data records yielded an approximate twofold difference for the same measurements when evaluated by the time-weighted-average (TWA)MF exposure metric. Performance of exposure meters was checked against standard fields generated in the laboratory, and studies of sources of variance in the in-home measurement protocols were carried out. Spectral measurements showed that the EBH's measured produced no appreciable high-frequency MFs. Data gathered during this work will be used in interpreting results from a component of the California Pregnancy Outcome Study, which evaluates the use of EBHs as a possible risk factor in miscarriage.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    This case study describes a DOE Zero Energy Ready Home in Greenbank, Washington that scored HERS 37 without PV and a -5 with PV. This 1,955 ft2 custom home has 6.5-inch structural insulated panel (SIPs) walls, a 10.25-inch SIPS roof, an R-20 insulated slab, a 2-ton ground source heat pump, radiant floor heat, 7.1 kWh PV, and triple-pane windows.

  7. Alternative Fuels Data Center: Missouri Transportation Data for Alternative

    Science.gov Websites

    Laboratory Case Studies Video thumbnail for Kansas City Home to Nation's Largest Network of EV Charging Stations Kansas City Home to Nation's Largest Network of EV Charging Stations Aug. 19, 2015 Video thumbnail Transportation Company Rolling May 16, 2014 Video thumbnail for The Heat Is on in St. Louis Buses The Heat Is on

  8. Technology Solutions Case Study: Insulated Siding Retrofit in a Cold Climate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    In this study, the U.S. Department of Energy’s team Building America Partner¬ship for Improved Residential Construction (BA-PIRC) worked with Kinsley Construction Company to evaluate the real-world performance of insulated sid¬ing when applied to an existing home. A 1960s home was selected for analysis. It is located in a cold climate (zone 6) where the addition of insulated siding and a carefully detailed water-resistive barrier have the potential to offer significant benefits. In particular, the team quantified building airtightness and heating energy use as a function of outdoor temperatures before and after the installa¬tion of the insulated siding.

  9. Smart Houses

    NASA Technical Reports Server (NTRS)

    1987-01-01

    GWS takes plans for a new home and subjects them to intensive computerized analysis that does 10,000 calculations relative to expected heat loss and heat gain, then provides specifications designed specifically for each structure as to heating, cooling, ventilation and insulation. As construction progresses, GWS inspects the work of the electrical, plumbing and insulation contractors and installs its own Smart House Radiant Barrier. On completion of the home, GWS technicians use a machine that creates a vacuum in the house and enables computer calculation of the air exchanged, a measure of energy efficiency. Key factor is the radiant barrier, borrowed from the Apollo program. This is an adaptation of a highly effective aluminized heat shield as a radiation barrier holding in or keeping out heat, cold air and water vapor.

  10. A winter survey of domestic heating among elderly patients.

    PubMed Central

    Morgan, R; Blair, A; King, D

    1996-01-01

    Elderly people have a greater need for domestic heating given the time they spend at home and the decline in the body thermoregulation that occurs with ageing. The use of domestic heating by 200 mentally competent newly admitted elderly in patients was evaluated by means of a questionnaire survey. Most patients (69%) were aware of the addition of value added tax (VAT) to their fuel bill and 31% said they had reduced the amount of heating they use because of this. A third of patients (29.5%) said they had difficulty keeping warm prior to this admission. The majority of patients said they could not manage to keep warm in the winter without financial hardship. In addition, 29% said they had reduced the amount spent on food in order to pay for fuel bills. This study suggests that cold may contribute to hospital admissions in elderly patients. This should have implications for government spending and taxation policy on domestic heating. PMID:8683507

  11. A winter survey of domestic heating among elderly patients.

    PubMed

    Morgan, R; Blair, A; King, D

    1996-02-01

    Elderly people have a greater need for domestic heating given the time they spend at home and the decline in the body thermoregulation that occurs with ageing. The use of domestic heating by 200 mentally competent newly admitted elderly in patients was evaluated by means of a questionnaire survey. Most patients (69%) were aware of the addition of value added tax (VAT) to their fuel bill and 31% said they had reduced the amount of heating they use because of this. A third of patients (29.5%) said they had difficulty keeping warm prior to this admission. The majority of patients said they could not manage to keep warm in the winter without financial hardship. In addition, 29% said they had reduced the amount spent on food in order to pay for fuel bills. This study suggests that cold may contribute to hospital admissions in elderly patients. This should have implications for government spending and taxation policy on domestic heating.

  12. Use of Low Level of Continuous Heat as an Adjunct to Physical Therapy Improves Knee Pain Recovery and the Compliance for Home Exercise in Patients With Chronic Knee Pain: A Randomized Controlled Trial.

    PubMed

    Petrofsky, Jerrold S; Laymon, Michael S; Alshammari, Faris S; Lee, Haneul

    2016-11-01

    Petrofsky, JS, Laymon, MS, Alshammari, FS, and Lee, H. Use of low level of continuous heat as an adjunct to physical therapy improves knee pain recovery and the compliance for home exercise in patients with chronic knee pain: a randomized controlled trial. J Strength Cond Res 30(11): 3107-3115, 2016-This study examined if the use of low level continuous heat (LLCH) wraps at home between physical therapy sessions at a clinic resulted in better therapy outcomes in patients with chronic knee pain. Fifty individuals with chronic nonspecific knee pain was randomly allocated to 2 groups: the LLCH group and the placebo group. All subjects underwent 1 hour of conventional physical therapy twice per week for 2 weeks at the outpatient clinic and they were asked to accomplish 1 hour of therapeutic exercise at home each day between sessions. The LLCH group applied LLCH knee wraps for 6 hours at home before home exercise while placebo group took a placebo ibuprofen. (This was done since placebo heat is impossible to use since subjects would notice that the wraps were cold) Before, during, and after intervention, pain intensity, active range of motion of the knee (AROM), knee strength, and home exercise compliance were measured. The LLCH group showed pain attenuation after 2 weeks of therapy sessions (p ≤ 0.05). AROM and strength of the knee significantly improved over time compared to the placebo group. Home exercise compliance was significantly higher in the LLCH group than placebo group (p ≤ 0.05). These results indicated that the use of LLCH as an adjunct to conventional physical therapy for chronic knee pain significantly improved pain attenuation and recovery of strength and movement in patients with chronic knee pain.

  13. Investigation of Accelerated Methods for the Determination of Available Alkali in Pozzolans

    DTIC Science & Technology

    1974-02-01

    181 p PC$9.50/MFS3.O0 Guidelines for Documentation of Computer Pro - Evaluation of Home Solar Heating System grams and Automated Data Systems UCL5...GrANT NO. 90, ORIGINATOR S REPORT NUMVIEEISI .PROJECT NO. Miscellaneous Pdper C-74-1 C. S. OTHER REPORT NOISP (AIr .dborms"M .0# Gmo Meol o SOl reo") tO...specification limit of 1.5 percent wifll not be exceeded when the pozzolan is evaluated by the present Standard Con - dition, 28 days at 38 C. In order to

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    PNNL, Florida HERO, and Energy Smart Home Plans helped Ravenwood Homes achieve a HERS 15 with PV or HERS 65 without PV on a home in Florida with SEER 16 AC, concrete block and rigid foam walls, high-performance windows, solar water heating, and 5.98 kW PV.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Provides consumers with home energy and money savings tips such as insulation, weatherization, heating, cooling, water heating, energy efficient windows, landscaping, lighting, and energy efficient appliances.

  16. Campbell Creek Research Homes FY 2012 Annual Performance Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gehl, Anthony C; Munk, Jeffrey D; Jackson, Roderick K

    The Campbell Creek project is funded and managed by the Tennessee Valley Authority (TVA) Technology Innovation, Energy Efficiency, Power Delivery & and Utilization Office. Technical support is provided under contract by the Oak Ridge National Laboratory (ORNL) and the Electric Power Research Institute.The project was designed to determine the relative energy efficiency of typical new home construction, energy efficiency retrofitting of existing homes, and high -performance new homes built from the ground up for energy efficiency. This project will compare three houses that represented the current construction practice as a base case (Builder House CC1); a modified house that couldmore » represent a major energy- efficient retrofit (Retrofit House CC2); and a house constructed from the ground up to be a high- performance home (High Performance House CC3). In order tTo enablehave a valid comparison, it was necessary to simulate occupancy in all three houses and heavily monitor the structural components and the energy usage by component. All three houses are two story, slab on grade, framed construction. CC1 and CC2 are approximately 2,400 square feet2. CC3 has a pantry option, that is primarily used as a mechanical equipment room, that adds approximately 100 square feet2. All three houses are all-electric (with the exception of a gas log fireplace that is not used during the testing), and use air-source heat pumps for heating and cooling. The three homes are located in Knoxville in the Campbell Creek Subdivision. CC1 and CC2 are next door to each other and CC3 is across the street and a couple of houses down. The energy data collected will be used to determine the benefits of retrofit packages and high -performance new home packages. There are over 300 channels of continuous energy performance and thermal comfort data collection in the houses (100 for each house). The data will also be used to evaluate the impact of energy -efficient upgrades ton the envelope, mechanical equipment, or demand -response options. Each retrofit will be evaluated incrementally, by both short -term measurements and computer modeling, using a calibrated model. This report is intended to document the comprehensive testing, data analysis, research, and findings within the January 2011 through October 2012 timeframe at the Campbell Creek research houses. The following sections will provide an in-depth assessment of the technology progression in each of the three research houses. A detailed assessment and evaluation of the energy performance of technologies tested will also be provided. Finally, lessons learned and concluding remarks will be highlighted.« less

  17. Destruction of Escherichia coli O157:H7, Salmonella, Listeria monocytogenes, and Staphylococcus aureus achieved during manufacture of whole-muscle beef Jerkyin home-style dehydrators.

    PubMed

    Dierschke, Sarah; Ingham, Steven C; Ingham, Barbara H

    2010-11-01

    Adequate lethality in jerky manufacture destroys appropriate levels of Escherichia coli O157:H7, Salmonella, Listeria monocytogenes, and Staphylococcus aureus. Our goal was to evaluate the lethality of four home-style dehydrator processes against these pathogens. Whole-muscle beef strips were inoculated with L. monocytogenes (five strains), S. aureus (five strains), or a mixed inoculum of E. coli O157:H7 (five strains) and Salmonella (eight strains). After allowing for attachment, strips were marinated in Colorado-, Original-, or Teriyaki-seasoned marinade for 22 to 24 h and dried in three home-style dehydrators (Garden Master, Excalibur, and Jerky Xpress) at 57.2 to 68.3°C. Samples were taken postmarination; after 4, 6, and 8 h of drying; and after drying, followed by heating for 10 min in a 135°C oven. Surviving inocula were enumerated. With a criterion of ≥ 5.0-log CFU/cm² reduction as the standard for adequate process lethality, none of the samples achieved the target lethality for any pathogen after 4 h of drying, even though all samples appeared "done" (water activity of less than 0.85). A postdehydration oven-heating step increased the proportion of samples meeting the target lethality after 4 h of drying to 71.9, 88.9, 55.6, and 77.8% for L. monocytogenes-, S. aureus-, E. coli O157:H7-, and Salmonella-inoculated samples, respectively, and after an 8-h drying to 90.6, 94.4, 83.3, and 91.7% of samples, respectively. Significantly greater lethality was seen with higher dehydrator temperature and significantly lower with Teriyaki-marinated samples. Heating jerky dried in a home-style dehydrator for 10 min in a 135°C oven would be an effective way to help ensure safety of this product.

  18. Clean energy choices: Tips on buying and using renewable energy at home

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NREL

    This brochure provides information on how consumers can use renewable energy in and around the home. Information on buying green power; using renewables to generate power; using passive and active solar and geothermal heat pumps to heat, cool and light buildings; and using alternative fuels and vehicles is included. Resources at the end of each chapter help readers find more information.

  19. Sealing ducts to save energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siuru, B.

    1996-07-01

    Large amounts of energy are wasted when heat leaks through ductwork located in uninsulated spaces. The Electric Power Research INstitute recently did a study that accurately measured these losses, then substantially reduced them by sealing the leaky ductwork. Six homes in the Pacific Northwest with significant duct leakage to the outside were selected for the study. The homes had electric resistance or heat pump, forced-air heating systems with a major portion of the supply and return ductwork in crawl spaces, attics, garages, etc. Measurements of duct leakage and heating system efficiency were done on all the homes before starting themore » duct sealing. Retrofitting included finding holes, gaps, cracks and disconnected joints in supply and return ducts as well as in plenums. When necessary, plenums were cut open for repairs. Leaks were sealed with Latex mastic and fiberglass tape. Outside ducts were covered or wrapped with insulation. Unducted returns were sealed with duct board. In some cases, leakage was corrected by merely reconnecting ducts and boots.« less

  20. The Consortium of Advanced Residential Buildings (CARB) - A Building America Energy Efficient Housing Partnership

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robb Aldrich; Lois Arena; Dianne Griffiths

    2010-12-31

    This final report summarizes the work conducted by the Consortium of Advanced Residential Buildings (CARB) (http://www.carb-swa.com/), one of the 'Building America Energy Efficient Housing Partnership' Industry Teams, for the period January 1, 2008 to December 31, 2010. The Building America Program (BAP) is part of the Department of Energy (DOE), Energy Efficiency and Renewable Energy, Building Technologies Program (BTP). The long term goal of the BAP is to develop cost effective, production ready systems in five major climate zones that will result in zero energy homes (ZEH) that produce as much energy as they use on an annual basis bymore » 2020. CARB is led by Steven Winter Associates, Inc. with Davis Energy Group, Inc. (DEG), MaGrann Associates, and Johnson Research, LLC as team members. In partnership with our numerous builders and industry partners, work was performed in three primary areas - advanced systems research, prototype home development, and technical support for communities of high performance homes. Our advanced systems research work focuses on developing a better understanding of the installed performance of advanced technology systems when integrated in a whole-house scenario. Technology systems researched included: - High-R Wall Assemblies - Non-Ducted Air-Source Heat Pumps - Low-Load HVAC Systems - Solar Thermal Water Heating - Ventilation Systems - Cold-Climate Ground and Air Source Heat Pumps - Hot/Dry Climate Air-to-Water Heat Pump - Condensing Boilers - Evaporative condensers - Water Heating CARB continued to support several prototype home projects in the design and specification phase. These projects are located in all five program climate regions and most are targeting greater than 50% source energy savings over the Building America Benchmark home. CARB provided technical support and developed builder project case studies to be included in near-term Joule Milestone reports for the following community scale projects: - SBER Overlook at Clipper Mill (mixed, humid climate) - William Ryan Homes - Tampa (hot, humid climate).« less

  1. 16 CFR Appendix G4 to Part 305 - Mobile Home Furnaces

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Mobile Home Furnaces G4 Appendix G4 to Part... CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER... Appendix G4 to Part 305—Mobile Home Furnaces Manufacturer's rated heating capacities (Btu's/hr.) Range of...

  2. 16 CFR Appendix G4 to Part 305 - Mobile Home Furnaces

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Mobile Home Furnaces G4 Appendix G4 to Part... CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER... Appendix G4 to Part 305—Mobile Home Furnaces Manufacturer's rated heating capacities (Btu's/hr.) Range of...

  3. 16 CFR Appendix G4 to Part 305 - Mobile Home Furnaces

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Mobile Home Furnaces G4 Appendix G4 to Part... CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER... Appendix G4 to Part 305—Mobile Home Furnaces Manufacturer's rated heating capacities (Btu's/hr.) Range of...

  4. 16 CFR Appendix G4 to Part 305 - Mobile Home Furnaces

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 1 2013-01-01 2013-01-01 false Mobile Home Furnaces G4 Appendix G4 to Part... CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER... Appendix G4 to Part 305—Mobile Home Furnaces Manufacturer's rated heating capacities (Btu's/hr.) Range of...

  5. 24 CFR 3280.707 - Heat producing appliances.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Heating, Cooling and Fuel Burning... oil burning comfort heating appliances shall have a flue loss of not more than 25 percent, and a...) Fuel-burning heat-producing appliances and refrigeration appliances, except ranges and ovens, shall be...

  6. Chemical heat pump

    DOEpatents

    Greiner, Leonard

    1980-01-01

    A chemical heat pump system is disclosed for use in heating and cooling structures such as residences or commercial buildings. The system is particularly adapted to utilizing solar energy, but also increases the efficiency of other forms of thermal energy when solar energy is not available. When solar energy is not available for relatively short periods of time, the heat storage capacity of the chemical heat pump is utilized to heat the structure as during nighttime hours. The design also permits home heating from solar energy when the sun is shining. The entire system may be conveniently rooftop located. In order to facilitate installation on existing structures, the absorber and vaporizer portions of the system may each be designed as flat, thin wall, thin pan vessels which materially increase the surface area available for heat transfer. In addition, this thin, flat configuration of the absorber and its thin walled (and therefore relatively flexible) construction permits substantial expansion and contraction of the absorber material during vaporization and absorption without generating voids which would interfere with heat transfer. The heat pump part of the system heats or cools a house or other structure through a combination of evaporation and absorption or, conversely, condensation and desorption, in a pair of containers. A set of automatic controls change the system for operation during winter and summer months and for daytime and nighttime operation to satisfactorily heat and cool a house during an entire year. The absorber chamber is subjected to solar heating during regeneration cycles and is covered by one or more layers of glass or other transparent material. Daytime home air used for heating the home is passed at appropriate flow rates between the absorber container and the first transparent cover layer in heat transfer relationship in a manner that greatly reduce eddies and resultant heat loss from the absorbant surface to ambient atmosphere.

  7. Builders Challenge High Performance Builder Spotlight - Artistic Homes, Albuquerque, NM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2009-01-01

    Building America Builders Challenge fact sheet on Artistic Homes of Albuquerque, New Mexico. Describes the first true zero E-scale home in a hot-dry climate with ducts inside, R-50 attic insulation, roof-mounted photovoltaic power system, and solar thermal water heating.

  8. Analysis of field test data on residential heating and cooling

    NASA Astrophysics Data System (ADS)

    Talbert, S. G.

    1980-12-01

    The computer program using field site data collected on 48 homes located in six cities in different climatic regions of the United States is discussed. In addition, a User's Guide was prepared for the computer program which is contained in a separate two-volume document entitled User's Guide for REAP: Residential Energy Analysis Program. Feasibility studies were conducted pertaining to potential improvements for REAP, including: the addition of an oil-furnace model; improving the infiltration subroutine; adding active and/or passive solar subroutines; incorporating a thermal energy storage model; and providing dual HVAC systems (e.g., heat pump-gas furnace). The purpose of REAP is to enable building designers and energy analysts to evaluate how such factors as building design, weather conditions, internal heat loads, and HVAC equipment performance, influence the energy requirements of residential buildings.

  9. 10 CFR Appendix G to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Unvented Home Heating Equipment

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Uniform Test Method for Measuring the Energy Consumption of Unvented Home Heating Equipment G Appendix G to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY..., App. G Appendix G to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of...

  10. 10 CFR Appendix G to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Unvented Home Heating Equipment

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... of Unvented Home Heating Equipment G Appendix G to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY..., App. G Appendix G to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of... gas control value (e.g., by label) by the manufacturer. 2.4 Electrical standby mode power measurement...

  11. 10 CFR Appendix G to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Unvented Home Heating Equipment

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Uniform Test Method for Measuring the Energy Consumption of Unvented Home Heating Equipment G Appendix G to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY..., App. G Appendix G to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of...

  12. An inexpensive economical solar heating system for homes

    NASA Technical Reports Server (NTRS)

    Allred, J. W.; Shinn, J. M., Jr.; Kirby, C. E.; Barringer, S. R.

    1976-01-01

    A low-cost solar home heating system to supplement existing warm-air heating systems is described. The report is written in three parts: (1) a brief background on solar heating, (2) experience with a demonstration system, and (3) information for the homeowner who wishes to construct such a system. Instructions are given for a solar heating installation in which the homeowner supplies all labor necessary to install off-the-shelf components estimated to cost $2,000. These components, which include solar collector, heat exchanger, water pump, storage tank, piping, and controls to make the system completely automatic, are available at local lumber yards, hardware stores, and plumbing supply stores, and are relatively simple to install. Manufacturers and prices of each component used and a rough cost analysis based on these prices are included. This report also gives performance data obtained from a demonstration system which was built and tested at the Langley Research Center.

  13. 24 CFR 3285.905 - Heating oil systems.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Heating oil systems. 3285.905... Installation Instructions § 3285.905 Heating oil systems. It is recommended that the installation instructions include the following information related to heating oil systems, when applicable: (a) Homes equipped with...

  14. 24 CFR 3285.905 - Heating oil systems.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Heating oil systems. 3285.905... Installation Instructions § 3285.905 Heating oil systems. It is recommended that the installation instructions include the following information related to heating oil systems, when applicable: (a) Homes equipped with...

  15. 24 CFR 3285.905 - Heating oil systems.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Heating oil systems. 3285.905... Installation Instructions § 3285.905 Heating oil systems. It is recommended that the installation instructions include the following information related to heating oil systems, when applicable: (a) Homes equipped with...

  16. Residential solar-heating system

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Complete residential solar-heating and hot-water system, when installed in highly-insulated energy-saver home, can supply large percentage of total energy demand for space heating and domestic hot water. System which uses water-heating energy storage can be scaled to meet requirements of building in which it is installed.

  17. Annual Performance of a Two-Speed, Dedicated Dehumidification Heat Pump in the NIST Net-Zero Energy Residential Test Facility

    PubMed Central

    Payne, W. Vance

    2017-01-01

    A 2715 ft2 (252 m2), two story, residential home of the style typical of the Gaithersburg, Maryland area was constructed in 2012 to demonstrate technologies for net-zero energy (NZE) homes (or ZEH). The NIST Net-Zero Energy Residential Test Facility (NZERTF) functions as a laboratory to support the development and adoption of cost-effective NZE designs, technologies, construction methods, and building codes. The primary design goal was to meet the comfort and functional needs of the simulated occupants. The first annual test period began on July 1, 2013 and ended June 30, 2014. During the first year of operation, the home's annual energy consumption was 13039 kWh (4.8 kWh ft-2, 51.7 kWh m-2), and the 10.2 kW solar photovoltaic system generated an excess of 484 kWh. During this period the heating and air conditioning of the home was performed by a novel air-source heat pump that utilized a reheat heat exchanger to allow hot compressor discharge gas to reheat the supply air during a dedicated dehumidification mode. During dedicated dehumidification, room temperature air was supplied to the living space until the relative humidity setpoint of 50% was satisfied. The heat pump consumed a total of 6225 kWh (2.3 kWh ft-2, 24.7 kWh m-2) of electrical energy for cooling, heating, and dehumidification. Annual cooling efficiency was 10.1 Btu W-1h-1 (2.95 W W-1), relative to the rated SEER of the heat pump of 15.8 Btu W-1h-1 (4.63 W W-1). Annual heating efficiency was 7.10 Btu W-1h-1 (2.09 W W-1), compared with the unit's rated HSPF of 9.05 Btu W-1h-1 (2.65 W W-1). These field measured efficiency numbers include dedicated dehumidification operation and standby energy use for the year. Annual sensible heat ratio was approximately 70%. Standby energy consumption was 5.2 % and 3.5 % of the total electrical energy used for cooling and heating, respectively. PMID:28729740

  18. Annual Performance of a Two-Speed, Dedicated Dehumidification Heat Pump in the NIST Net-Zero Energy Residential Test Facility.

    PubMed

    Payne, W Vance

    2016-01-01

    A 2715 ft 2 (252 m 2 ), two story, residential home of the style typical of the Gaithersburg, Maryland area was constructed in 2012 to demonstrate technologies for net-zero energy (NZE) homes (or ZEH). The NIST Net-Zero Energy Residential Test Facility (NZERTF) functions as a laboratory to support the development and adoption of cost-effective NZE designs, technologies, construction methods, and building codes. The primary design goal was to meet the comfort and functional needs of the simulated occupants. The first annual test period began on July 1, 2013 and ended June 30, 2014. During the first year of operation, the home's annual energy consumption was 13039 kWh (4.8 kWh ft -2 , 51.7 kWh m -2 ), and the 10.2 kW solar photovoltaic system generated an excess of 484 kWh. During this period the heating and air conditioning of the home was performed by a novel air-source heat pump that utilized a reheat heat exchanger to allow hot compressor discharge gas to reheat the supply air during a dedicated dehumidification mode. During dedicated dehumidification, room temperature air was supplied to the living space until the relative humidity setpoint of 50% was satisfied. The heat pump consumed a total of 6225 kWh (2.3 kWh ft -2, 24.7 kWh m -2 ) of electrical energy for cooling, heating, and dehumidification. Annual cooling efficiency was 10.1 Btu W -1 h -1 (2.95 W W -1 ), relative to the rated SEER of the heat pump of 15.8 Btu W -1 h -1 (4.63 W W -1 ). Annual heating efficiency was 7.10 Btu W -1 h -1 (2.09 W W -1 ), compared with the unit's rated HSPF of 9.05 Btu W -1 h -1 (2.65 W W -1 ). These field measured efficiency numbers include dedicated dehumidification operation and standby energy use for the year. Annual sensible heat ratio was approximately 70%. Standby energy consumption was 5.2 % and 3.5 % of the total electrical energy used for cooling and heating, respectively.

  19. DOE Zero Energy Ready Home Case Study: Alliance Green Builders, Casa Aguila

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pacific Northwest National Laboratory

    Alliance Green Builders built this 3,129-ft2 home in the hills above Ramona, California, to the high-performance criteria of the DOE Zero Energy Ready Home (ZERH) program. The home should perform far better than net zero thanks to a super-efficient building shell, a wind turbine, three suntracking solar photovoltaic arrays, and solar thermal water heating.

  20. Indirect Solar Water Heating in Single-Family, Zero Energy Ready Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aldrich, Robb

    2016-02-17

    Solar water heating systems are not new, but they have not become prevalent in most of the U.S. Most of the country is cold enough that indirect solar thermal systems are required for freeze protection, and average installed cost of these systems is $9,000 to $10,000 for typical systems on single-family homes. These costs can vary significantly in different markets and with different contractors, and federal and regional incentives can reduce these up-front costs by 50% or more. In western Massachusetts, an affordable housing developer built a community of 20 homes with a goal of approaching zero net energy consumption.more » In addition to excellent thermal envelopes and PV systems, the developer installed a solar domestic water heating system (SDHW) on each home. The Consortium for Advanced Residential Buildings (CARB), a research consortium funded by the U.S. Department of Energy Building America program, commissioned some of the systems, and CARB was able to monitor detailed performance of one system for 28 months.« less

  1. 24 CFR 3280.707 - Heat producing appliances.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... with a comfort heating system. (i) When a manufactured home is manufactured to contain a heating... oil burning comfort heating appliances shall have a flue loss of not more than 25 percent, and a thermal efficiency of not less than that specified in nationally recognized standards (See § 3280.703). (b...

  2. Should You Have the Air Ducts in Your Home Cleaned?

    EPA Pesticide Factsheets

    2017-02-14

    Duct cleaning generally refers to the cleaning of various heating and cooling system components of forced air systems, including the supply and return air ducts and registers, grilles and diffusers, heat exchangers heating and cooling coils.

  3. Net Zero Energy Manufactured Homes May Be on their Way

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gilbride, Theresa L.; Dentz, Jordan

    This article, published in Home Energy Magazine, describes a research project sponsored by the U.S. Department of Energy's Building America program, to construct and test the first manufactured home in the United States built to the performance criteria of DOE's Zero Energy Ready Home program. A 15-month study was conducted to compare the real-world performance of the DOE Zero Energy Ready home and two other manufactured homes - one built to just above industry standard construction and one built to the ENERGY STAR Certified Home criteria. The homes were built by Clayton Homes' Southern Energy Division and testing was sponsoredmore » by DOE's Building America program and conducted by the Levy Partnership. The DOE ZERH had increased initial construction costs of $6,607 compared to the standard home versus $4,340 for the ENERGY STAR home but reduced energy bills by $50 per month compared to a $33/month savings for the ENERGY STAR home, and monthly savings will continue for the life of the home. Savings were especially noticeable in the summer in this cooling-dominated test location. The DOE ZERH cut cooling costs in half compared to the ENERGY STAR home which performed only slightly better than the standard home in summer, while winter savings between the two advanced homes were more similar. Two technology advances were tested in the DOE ZERH home. Instead of the typical ducted heating and cooling system, the DOE ZERH home was equipped with a ductless heat pump; to condition the bedroom, holes were cut into bedroom walls and small fans were installed to pull air into those rooms, while door undercuts and transfer grilles provide return paths. A novel dense-pack attic insulation was also implemented.« less

  4. Experiments Demonstrate Geothermal Heating Process

    ERIC Educational Resources Information Center

    Roman, Harry T.

    2012-01-01

    When engineers design heat-pump-based geothermal heating systems for homes and other buildings, they can use coil loops buried around the perimeter of the structure to gather low-grade heat from the earth. As an alternative approach, they can drill well casings and store the summer's heat deep in the earth, then bring it back in the winter to warm…

  5. EnergySavers: Tips on Saving Money & Energy at Home (Brochure)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The U.S. Department of Energy's consumer guide to saving money and energy at home and on the road. It consists of the following articles: (1) Save Money and Energy Today - Get started with things you can do now, and use the whole-house approach to ensure that your investments are wisely made to save you money and energy; (2) Your Home's Energy Use - Find out how your home uses energy, and where it's losing the most energy so you can develop a plan to save in the short and long term; (3) Air Leaks and Insulation - Seal airmore » leaks and insulate your home properly so your energy dollars don't seep through the cracks; (4) Heating and Cooling - Use efficient systems to heat and cool your home, and save money and increase comfort by properly maintaining and upgrading equipment; (5) Water Heating - Use the right water heater for your home, insulate it and lower its temperature, and use less water to avoid paying too much; (6) Windows - Enjoy light and views while saving money by installing energy-efficient windows, and use strategies to keep your current windows from losing energy; (7) Lighting - Choose today's energy-efficient lighting for some of the easiest and cheapest ways to reduce your electric bill; (8) Appliances - Use efficient appliances through-out your home, and get greater performance with lower energy bills; (9) Home Office and Electronics - Find out how much energy your electronics use, reduce their out-put when you're not using them, and choose efficient electronics to save money; (10) Renewable Energy - Use renewable energy at home such as solar and wind to save energy dollars while reducing environmental impact; (11) Transportation - Choose efficient transportation options and drive more efficiently to save at the gas pump; and (12) References - Use our reference list to learn more about energy efficiency and renewable energy.« less

  6. 10 CFR Appendix G to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Unvented Home Heating Equipment

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... of Unvented Home Heating Equipment G Appendix G to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY..., App. G Appendix G to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of.... 28, 1984] Effective Date Note: At 77 FR 74571, Dec. 17, 2012, appendix G to subpart B of part 430 was...

  7. DOE ZERH Case Study: TC Legend Homes, Bellingham Power House, Bellingham, WA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    Case study of a DOE 2015 Housing Innovation Award winning custom home in the marine climate that got HERS 34 without PV or HERS -12 with PV, with 6” SIP walls and 10” SIP roof; R-28 ICF around slab, R-20 rigid foam under slab; radiant floor heat and passive design; air-to-water heat pump COP 4.4; HRV; earth tube ventilation; triple-pane windows, 100% LED.

  8. Home Energy Saver

    Science.gov Websites

    (heating, cooling, water heating, major appliances, small appliances, and lighting) are included. HES ;black box"-we extensively document all methodologies and assumptions. Users begin their exploration

  9. Winter Storms and Extreme Cold

    MedlinePlus

    ... your home to keep out the cold with insulation, caulking, and weather stripping. Learn how to keep ... and grills outdoors and away from windows. Never heat your home with a gas stovetop or oven. ...

  10. Emergency hospital admissions associated with a non-randomised housing intervention meeting national housing quality standards: a longitudinal data linkage study.

    PubMed

    Rodgers, Sarah E; Bailey, Rowena; Johnson, Rhodri; Berridge, Damon; Poortinga, Wouter; Lannon, Simon; Smith, Robert; Lyons, Ronan A

    2018-06-20

    We investigated tenant healthcare utilisation associated with upgrading 8558 council houses to a national quality standard. Homes received multiple internal and external improvements and were analysed using repeated measures of healthcare utilisation. The primary outcome was emergency hospital admissions for cardiorespiratory conditions and injuries for residents aged 60 years and over. Secondary outcomes included each of the separate conditions, for tenants aged 60 and over, and for all ages. Council home address and intervention records for eight housing cointerventions were anonymously linked to demographic data, hospital admissions and deaths for individuals in a dynamic cohort. Counts of health events were analysed using multilevel regression models to investigate associations between receipt of each housing improvement, adjusting for potential confounding factors and regional trends. Residents aged 60 years and over living in homes when improvements were made were associated with up to 39% fewer admissions compared with those living in homes that were not upgraded (incidence rate ratio=0.61, 95% CI 0.53 to 0.72). Reduced admissions were associated with electrical systems, windows and doors, wall insulation, and garden paths. There were small non-significant reductions for the primary outcome associated with upgrading heating, adequate loft insulation, new kitchens and new bathrooms. Results suggest that hospital admissions can be avoided through improving whole home quality standards. This is the first large-scale longitudinal evaluation of a whole home intervention that has evaluated multiple improvement elements using individual-level objective routine health data. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. A Project to Design and Build Compact Heat Exchangers

    ERIC Educational Resources Information Center

    Davis, Richard A.

    2005-01-01

    Students designed and manufactured compact, shell-and-tube heat exchangers in a project-based learning exercise integrated with our heat transfer course. The heat exchangers were constructed from common building materials available at home improvement centers. The cost of materials for a device was less than $20. The project gave students…

  12. Insulated Concrete Homes Increase Durability and Energy Efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2001-05-01

    New houses designed by Mercedes Homes in Melbourne, Florida, save their homeowners money by using energy efficient features such as a high performance heat pump and solar control glazing to reduce cooling costs.

  13. Generation system impacts of storage heating and storage water heating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gellings, C.W.; Quade, A.W.; Stovall, J.P.

    Thermal energy storage systems offer the electric utility a means to change customer energy use patterns. At present, however, the costs and benefit to both the customers and utility are uncertain. As part of a nationwide demonstration program Public Service Electric and Gas Company installed storage space heating and water heating appliances in residential homes. Both the test homes and similiar homes using conventional space and water heating appliances were monitored, allowing for detailed comparisons between the two systems. The purpose of this paper is to detail the methodology used and the results of studies completed on the generation systemmore » impacts of storage space and water heating systems. Other electric system impacts involving service entrance size, metering, secondary distribution and primary distribution were detailed in two previous IEEE Papers. This paper is organized into three main sections. The first gives background data on PSEandG and their experience in a nationwide thermal storage demonstration project. The second section details results of the demonstration project and studies that have been performed on the impacts of thermal storage equipment. The last section reports on the conclusions arrived at concerning the impacts of thermal storage on generation. The study was conducted in early 1982 using available data at that time, while PSEandG system plans have changed since then, the conclusions are pertinent and valuable to those contemplating inpacts of thermal energy storage.« less

  14. Save Energy: Save Money!

    ERIC Educational Resources Information Center

    Eccli, Eugene; And Others

    This publication is a collection of inexpensive energy saving tips and home improvements for home owners, particularly in low-income areas or in older homes. Section titles are: (1) Keeping Warm; (2) Getting Heat Where You Need It; (3) Using the Sun; (4) Furnaces, Stoves, and Fireplaces; (5) Insulation and Other Energy Needs; (6) Do-It-Yourself…

  15. Technology Solutions Case Study: Innovative Retrofit Foundation Insulation Strategies, Minneapolis, Minnesota

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Basements in climates 6 & 7 can account for a fraction of a home's total heat loss when fully conditioned. These foundations are a source of moisture, with convection in open block cavities redistributing water from the wall base, usually when heating. Even when block cavities are capped, the cold foundation concrete can act as a moisture source for wood rim joist components that are in contact with the wall. As below-grade basements are increasingly retrofitted for habitable space, cold foundation walls pose increased challenges for moisture durability, energy use, and occupant comfort. To address this challenge, the NorthernSTAR Buildingmore » America Partnership evaluated a retrofit insulation strategy for foundations that is designed for use with open-core concrete block foundation walls. The three main goals were to improve moisture control, improve occupant comfort, and reduce heat loss.« less

  16. Impact of Increasing Home Size on Energy Demand, The

    EIA Publications

    2012-01-01

    Homes built since 1990 are on average 27% larger than homes built in earlier decades, a significant trend because most energy end-uses are correlated with the size of the home. As square footage increases, the burden on heating and cooling equipment rises, lighting requirements increase, and the likelihood that the household uses more than one refrigerator increases. Square footage typically stays fixed over the life of a home and it is a characteristic that is expensive, even impractical to alter to reduce energy consumption.

  17. Evaluation of Waste Heat Recovery and Utilization from Residential Appliances and Fixtures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tomlinson, John J; Christian, Jeff; Gehl, Anthony C

    Executive Summary In every home irrespective of its size, location, age, or efficiency, heat in the form of drainwater or dryer exhaust is wasted. Although from a waste stream, this energy has the potential for being captured, possibly stored, and then reused for preheating hot water or air thereby saving operating costs to the homeowner. In applications such as a shower and possibly a dryer, waste heat is produced at the same time as energy is used, so that a heat exchanger to capture the waste energy and return it to the supply is all that is needed. In othermore » applications such as capturing the energy in drainwater from a tub, dishwasher, or washing machine, the availability of waste heat might not coincide with an immediate use for energy, and consequently a heat exchanger system with heat storage capacity (i.e. a regenerator) would be necessary. This study describes a two-house experimental evaluation of a system designed to capture waste heat from the shower, dishwasher clothes washer and dryer, and to use this waste heat to offset some of the hot water energy needs of the house. Although each house was unoccupied, they were fitted with equipment that would completely simulate the heat loads and behavior of human occupants including operating the appliances and fixtures on a demand schedule identical to Building American protocol (Hendron, 2009). The heat recovery system combined (1) a gravity-film heat exchanger (GFX) installed in a vertical section of drainline, (2) a heat exchanger for capturing dryer exhaust heat, (3) a preheat tank for storing the captured heat, and (4) a small recirculation pump and controls, so that the system could be operated anytime that waste heat from the shower, dishwasher, clothes washer and dryer, and in any combination was produced. The study found capturing energy from the dishwasher and clothes washer to be a challenge since those two appliances dump waste water over a short time interval. Controls based on the status of the dump valve on these two appliances would have eliminated uncertainty in knowing when waste water was flowing and the recovery system operated. The study also suggested that capture of dryer exhaust heat to heat incoming air to the dryer should be examined as an alternative to using drying exhaust energy for water heating. The study found that over a 6-week test period, the system in each house was able to recover on average approximately 3000 W-h of waste heat daily from these appliance and showers with slightly less on simulated weekdays and slightly more on simulated weekends which were heavy wash/dry days. Most of these energy savings were due to the shower/GFX operation, and the least savings were for the dishwasher/GFX operation. Overall, the value of the 3000 W-h of displaced energy would have been $0.27/day based on an electricity price of $.09/kWh. Although small for today s convention house, these savings are significant for a home designed to approach maximum affordable efficiency where daily operating costs for the whole house are less than a dollar per day. In 2010 the actual measured cost of energy in one of the simulated occupancy houses which waste heat recovery testing was undertaken was $0.77/day.« less

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, B.

    If seeing is believing, Kyle and Christine Sarratt are believers. The couple has been living in their passive solar custom home for almost two years, long enough to see a steady stream of eye-opening utility bills and to experience the quality and comfort of energy-efficient design. Skeptical of solar homes at first, the Sarratts found an energy-conscious designer that showed them how they could realize their home-building dreams and live in greater comfort while spending less money. As Kyle says, {open_quotes}We knew almost nothing about solar design and weren`t looking for it, but when we realized we could get everythingmore » we wanted in a home and more, we were sold.{close_quotes} Now the couple is enjoying the great feeling of solar and wood heat in the winter, natural cooling in the summer and heating/cooling bills that average less than $20/month. The Sarratts` home overlooks a large lake near the town of Rogers, tucked up in the northwest corner of Arkansas. It is one of three completed homes out of 29 planned for the South Sun Estates subdivision, where homes are required by covenant to incorporate passive solar design principles. Orlo Stitt, owner of Stitt Energy Systems and developer of the subdivision, has been designing passive solar, energy-efficient homes for twenty years. His passive solar custom home development is the first in Arkansas.« less

  19. Solar Energy for Space Heating & Hot Water.

    ERIC Educational Resources Information Center

    Energy Research and Development Administration, Washington, DC. Div. of Solar Energy.

    This pamphlet reviews the direct transfer of solar energy into heat, particularly for the purpose of providing space and hot water heating needs. Owners of buildings and homes are provided with a basic understanding of solar heating and hot water systems: what they are, how they perform, the energy savings possible, and the cost factors involved.…

  20. Evaluation of Biomass-Derived Distillate Fuel as Renewable Heating Oil

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mante, Ofei D.; Butcher, Thomas A.; Wei, George

    The utilization of advanced biofuels in stationary applications, such as home heating, is considered as an early entry point for biomass-derived fuels into the distillate fuel market sector. Two renewable fuels produced by a biomass fluidized catalytic cracking (BFCC) process, followed by hydroprocessing and fractionation, were tested. The evaluation was performed on a pure (100%) distillate fraction, 50% blend of the distillate fraction with petroleum-based heating oil, and 20% blend of a heavier gas oil fraction. Combustion experiments were carried out in a transparent quartz chamber and a typical oil-fired residential boiler. The flame stability, size, and shape produced bymore » the fuels were examined. The flue gas was analyzed for O 2, CO, NO x, and smoke. The elastomer compatibility test was performed with nitrile slabs at 43 °C for 1 month. Fuel stability was examined at 80 °C for 1 week. The results from the combustion studies suggest that the distillate fuel blends could be used as alternative fuels to No. 2 heating oil, even up to 100% without any operational issues. The distillate fuels were found to be stable. and the nitrile slab volume swell (~10%) suggests that the fuel could be compatible to legacy elastomers.« less

  1. Evaluation of Biomass-Derived Distillate Fuel as Renewable Heating Oil

    DOE PAGES

    Mante, Ofei D.; Butcher, Thomas A.; Wei, George; ...

    2015-09-18

    The utilization of advanced biofuels in stationary applications, such as home heating, is considered as an early entry point for biomass-derived fuels into the distillate fuel market sector. Two renewable fuels produced by a biomass fluidized catalytic cracking (BFCC) process, followed by hydroprocessing and fractionation, were tested. The evaluation was performed on a pure (100%) distillate fraction, 50% blend of the distillate fraction with petroleum-based heating oil, and 20% blend of a heavier gas oil fraction. Combustion experiments were carried out in a transparent quartz chamber and a typical oil-fired residential boiler. The flame stability, size, and shape produced bymore » the fuels were examined. The flue gas was analyzed for O 2, CO, NO x, and smoke. The elastomer compatibility test was performed with nitrile slabs at 43 °C for 1 month. Fuel stability was examined at 80 °C for 1 week. The results from the combustion studies suggest that the distillate fuel blends could be used as alternative fuels to No. 2 heating oil, even up to 100% without any operational issues. The distillate fuels were found to be stable. and the nitrile slab volume swell (~10%) suggests that the fuel could be compatible to legacy elastomers.« less

  2. Measure Guideline: Heat Pump Water Heaters in New and Existing Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shapiro, C.; Puttagunta, S.; Owens, D.

    2012-02-01

    This Building America Measure Guideline is intended for builders, contractors, homeowners, and policy-makers. This document is intended to explore the issues surrounding heat pump water heaters (HPWHs) to ensure that homeowners and contractors have the tools needed to appropriately and efficiently install HPWHs. Heat pump water heaters (HPWHs) promise to significantly reduce energy consumption for domestic hot water (DHW) over standard electric resistance water heaters (ERWHs). While ERWHs perform with energy factors (EFs) around 0.9, new HPWHs boast EFs upwards of 2.0. High energy factors in HPWHs are achieved by combining a vapor compression system, which extracts heat from themore » surrounding air at high efficiencies, with electric resistance element(s), which are better suited to meet large hot water demands. Swapping ERWHs with HPWHs could result in roughly 50% reduction in water heating energy consumption for 35.6% of all U.S. households. This Building America Measure Guideline is intended for builders, contractors, homeowners, and policy-makers. While HPWHs promise to significantly reduce energy use for DHW, proper installation, selection, and maintenance of HPWHs is required to ensure high operating efficiency and reliability. This document is intended to explore the issues surrounding HPWHs to ensure that homeowners and contractors have the tools needed to appropriately and efficiently install HPWHs. Section 1 of this guideline provides a brief description of HPWHs and their operation. Section 2 highlights the cost and energy savings of HPWHs as well as the variables that affect HPWH performance, reliability, and efficiency. Section 3 gives guidelines for proper installation and maintenance of HPWHs, selection criteria for locating HPWHs, and highlights of important differences between ERWH and HPWH installations. Throughout this document, CARB has included results from the evaluation of 14 heat pump water heaters (including three recently released HPWH products) installed in existing homes in the northeast region of the United States.« less

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    This case study describes a DOE Zero Energy Ready Home in Seattle, WA, that scored HERS 42 without PV and a -1 with PV. This 3,192 ft2 custom home has 6-inch SIP walls, a 12-inch SIP roof, an R-28 ICF-insulated foundation slab edge with R-20 rigid foam under the slab; an air-to-water heat pump plus radiant floor heat; 100% LED lighting; filtered-fan-powered fresh air intake; triple-pane windows, 9.7 kWh PV for electric car charging station.

  4. 38 CFR 36.4501 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... as a home, consisting of one residential unit only and not containing any business unit. Energy... a solar heating system, a solar heating and cooling system, or a combined solar heating and cooling system, or through application of a residential energy conservation measure as prescribed in 38 U.S.C...

  5. 38 CFR 36.4501 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... as a home, consisting of one residential unit only and not containing any business unit. Energy... a solar heating system, a solar heating and cooling system, or a combined solar heating and cooling system, or through application of a residential energy conservation measure as prescribed in 38 U.S.C...

  6. 24 CFR 3280.507 - Comfort heat gain.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Thermal Protection § 3280.507 Comfort heat... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Comfort heat gain. 3280.507 Section 3280.507 Housing and Urban Development Regulations Relating to Housing and Urban Development (Continued...

  7. 38 CFR 36.4501 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... as a home, consisting of one residential unit only and not containing any business unit. Energy... a solar heating system, a solar heating and cooling system, or a combined solar heating and cooling system, or through application of a residential energy conservation measure as prescribed in 38 U.S.C...

  8. KSC-01pp1023

    NASA Image and Video Library

    2001-05-24

    KENNEDY SPACE CENTER, FLA. -- In the Orbiter Processing Facility, a worker points to some of the tiles on orbiter Atlantis that are being dried by clusters of 200-300 watt heat lamps. Significant rainstorms during the orbiter’s turnaround for a ferry flight home from Edwards Air Force Base, Calif., caused a moisture problem. The tiles are part of the Thermal Protection System used on orbiters for extreme temperatures encountered during landing. Engineers are evaluating the current procedures to assure the tiles are in a safe and flight-ready condition

  9. KSC-01PP1024

    NASA Image and Video Library

    2001-05-24

    KENNEDY SPACE CENTER, FLA. -- In the Orbiter Processing Facility, a worker points to some of the tiles on orbiter Atlantis that are being dried by clusters of 200-300 watt heat lamps. Significant rainstorms during the orbiter’s turnaround for a ferry flight home from Edwards Air Force Base, Calif., caused a moisture problem. The tiles are part of the Thermal Protection System used on orbiters for extreme temperatures encountered during landing. Engineers are evaluating the current procedures to assure the tiles are in a safe and flight-ready condition

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    This builder certified its first DOE Zero Energy Ready Home and won a Production Builder honor in the 2014 Housing Innovation Awards. It is the first home in the world to use a tri-generation system to supply electricity, heating, and cooling on site.

  11. Evaluation of a High-Performance Solar Home in Loveland, Colorado

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hendron, R.; Eastment, M.; Hancock, E.

    2006-01-01

    Building America (BA) partner McStain Neighborhoods built the Discovery House in Loveland, Colorado, with an extensive package of energy-efficient features, including a high-performance envelope, efficient mechanical systems, a solar water heater integrated with the space-heating system, a heat-recovery ventilator (HRV), and ENERGY STAR? appliances. The National Renewable Energy Laboratory (NREL) and Building Science Consortium (BSC) conducted short-term field-testing and building energy simulations to evaluate the performance of the house. These evaluations are utilized by BA to improve future prototype designs and to identify critical research needs. The Discovery House building envelope and ducts were very tight under normal operating conditions.more » The HRV provided fresh air at a rate of about 75 cfm (35 l/s), consistent with the recommendations of ASHRAE Standard 62.2. The solar hot water system is expected to meet the bulk of the domestic hot water (DHW) load (>83%), but only about 12% of the space-heating load. DOE-2.2 simulations predict whole-house source energy savings of 54% compared to the BA Benchmark [1]. The largest contributors to energy savings beyond McStain's standard practice are the solar water heater, HRV, improved air distribution, high-efficiency boiler, and compact fluorescent lighting package.« less

  12. Evaluation of a High-Performance Solar Home in Loveland, Colorado: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hendron, R.; Eastment, M.; Hancock, E.

    Building America (BA) partner McStain Neighborhoods built the Discovery House in Loveland, Colorado, with an extensive package of energy-efficient features, including a high-performance envelope, efficient mechanical systems, a solar water heater integrated with the space-heating system, a heat-recovery ventilator (HRV), and ENERGY STAR appliances. The National Renewable Energy Laboratory (NREL) and Building Science Consortium (BSC) conducted short-term field-testing and building energy simulations to evaluate the performance of the house. These evaluations are utilized by BA to improve future prototype designs and to identify critical research needs. The Discovery House building envelope and ducts were very tight under normal operating conditions.more » The HRV provided fresh air at a rate of about 35 l/s (75 cfm), consistent with the recommendations of ASHRAE Standard 62.2. The solar hot water system is expected to meet the bulk of the domestic hot water (DHW) load (>83%), but only about 12% of the space-heating load. DOE-2.2 simulations predict whole-house source energy savings of 54% compared to the BA Benchmark. The largest contributors to energy savings beyond McStain's standard practice are the solar water heater, HRV, improved air distribution, high-efficiency boiler, and compact fluorescent lighting package.« less

  13. Diffusion of solar energy technologies in the new-construction market: A survey of new solar-home and conventional-home buyers

    NASA Astrophysics Data System (ADS)

    Rains, D.; Dunipace, D.; Woo, C. K.

    1981-02-01

    Consumer motivations for choosing a solar energy equipped home when the nonsolar or conventional model was available were investigated. The approach was to test the relative importance of demographic, dwelling unit, and heating system characteristics in household decisions to purchase a home equipped with solar energy devices. Two statistical models were developed: one to examine the relationship between the types of home buyers (as an identifiable market segment) and the decision to purchase a solar home; and the other to compare the energy use of solar vs. conventional homes selected in the sample.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arena, Lois

    The U.S. Department of Energy’s Building America research team Consortium for Advanced Residential Buildings (CARB) worked with the EcoVillage cohousing community in Ithaca, New York, on the Third Residential EcoVillage Experience neighborhood. This communityscale project consists of 40 housing units—15 apartments and 25 single-family residences. Units range in size from 450 ft2 to 1,664 ft2 and cost from $80,000 for a studio apartment to $235,000 for a three- or four-bedroom single-family home. For the research component of this project, CARB analyzed current heating system sizing methods for superinsulated homes in cold climates to determine if changes in building load calculationmore » methodology should be recommended. Actual heating energy use was monitored and compared to results from the Air Conditioning Contractors of America’s Manual J8 (MJ8) and the Passive House Planning Package software. Results from that research indicate that MJ8 significantly oversizes heating systems for superinsulated homes and that thermal inertia and internal gains should be considered for more accurate load calculations.« less

  15. RUDO: A Home Ambient Intelligence System for Blind People

    PubMed Central

    Hudec, Milan

    2017-01-01

    The article introduces an ambient intelligence system for blind people which besides providing assistance in home environment also helps with various situations and roles in which blind people may find themselves involved. RUDO, the designed system, comprises several modules that mainly support or ensure recognition of approaching people, alerting to other household members’ movement in the flat, work on a computer, supervision of (sighted) children, cooperation of a sighted and a blind person (e.g., when studying), control of heating and zonal regulation by a blind person. It has a unified user interface that gives the blind person access to individual functions. The interface for blind people offers assistance with work on a computer, including writing in Braille on a regular keyboard and specialized work in informatics and electronics (e.g., programming). RUDO can complement the standard aids used by blind people at home, it increases their independence and creates conditions that allow them to become fully involved. RUDO also supports blind people sharing a home with sighted people, which contributes to their feeling of security and greater inclusion in society. RUDO has been implemented in a household for two years, which allows an evaluation of its use in practice. PMID:28829372

  16. RUDO: A Home Ambient Intelligence System for Blind People.

    PubMed

    Hudec, Milan; Smutny, Zdenek

    2017-08-22

    The article introduces an ambient intelligence system for blind people which besides providing assistance in home environment also helps with various situations and roles in which blind people may find themselves involved. RUDO, the designed system, comprises several modules that mainly support or ensure recognition of approaching people, alerting to other household members' movement in the flat, work on a computer, supervision of (sighted) children, cooperation of a sighted and a blind person (e.g., when studying), control of heating and zonal regulation by a blind person. It has a unified user interface that gives the blind person access to individual functions. The interface for blind people offers assistance with work on a computer, including writing in Braille on a regular keyboard and specialized work in informatics and electronics (e.g., programming). RUDO can complement the standard aids used by blind people at home, it increases their independence and creates conditions that allow them to become fully involved. RUDO also supports blind people sharing a home with sighted people, which contributes to their feeling of security and greater inclusion in society. RUDO has been implemented in a household for two years, which allows an evaluation of its use in practice.

  17. Technology Solutions Case Study: Investigating Solutions to Wind Washing Issues in Two-Story Florida Homes: Phase 2, Southeastern United States

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    In many two-story homes, there are attic spaces above the first-floor of the home that border portions of the second-story conditioned space. These spaces have breaches of the air and thermal boundaries, creating a phenomenon known as wind washing. This can cause attic air above the first-floor space to be driven into the cavity between the first and second floors by wind, thermal buoyancy forces, or mechanical driving forces as well as circulation of hot attic air against the wallboard because of gaps between insulation batts installed on knee walls and the gypsum wallboard. In this project, the U.S. Departmentmore » of Energy team Building America Partnership for Improved Residential Construction (BA-PIRC) investigated wind washing in 56 homes. The goals were to identify the failure mechanisms that lead to wind washing, characterize the pathways for air and heat to enter the house, and evaluate the seasonal energy savings and peak demand reduction that can result from repairing these wind washing problems. Based on this research, the team developed recommendations for cost-effective retrofit solutions and information that can help avoid these problems in new construction.« less

  18. Understanding Latent Heat of Vaporization.

    ERIC Educational Resources Information Center

    Linz, Ed

    1995-01-01

    Presents a simple exercise for students to do in the kitchen at home to determine the latent heat of vaporization of water using typical household materials. Designed to stress understanding by sacrificing precision for simplicity. (JRH)

  19. 78 FR 34105 - Proposed Information Collection Activity; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-06

    ... include Natural Gas, Electricity, Fuel Oil, Propane, Wood and Coal. The average annual primary home energy... using a secondary source of heat. Annual Heating Fuel Consumption: The grantee would need to collect...

  20. Wood energy for residential heating in Alaska: current conditions, attitudes, and expected use

    Treesearch

    David L. Nicholls; Allen M. Brackley; Valerie Barber

    2010-01-01

    This study considered three aspects of residential wood energy use in Alaska: current conditions and fuel consumption, knowledge and attitudes, and future use and conditions. We found that heating oil was the primary fuel for home heating in southeast and interior Alaska, whereas natural gas was used most often in south-central Alaska (Anchorage). Firewood heating...

  1. Solar Heating and Cooling of Residential Buildings: Sizing, Installation and Operation of Systems.

    ERIC Educational Resources Information Center

    Colorado State Univ., Ft. Collins. Solar Energy Applications Lab.

    This training course and a companion course titled "Design of Systems for Solar Heating and Cooling of Residential Buildings," are designed to train home designers and builders in the fundamentals of solar hydronic and air systems for space heating and cooling and domestic hot water heating for residential buildings. Each course, organized in 22…

  2. Extreme Cold: A Prevention Guide to Promote Your Personal Health and Safety

    MedlinePlus

    ... possible, weatherproof your home by adding weather- stripping, insulation, insulated doors and storm windows, or thermal-pane ... colored cloth for added traction) 4 Indoor Safety Heat Your Home Safely If you plan to use ...

  3. New Whole-House Case Study: William Ryan Homes, Tampa, Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    The builder worked with Consortium for Advanced Residential Buildings to design HERS-65 homes with energy-efficient heat pumps and programmable thermostats with humidity controls, foam-filled concrete block walls, draining house wrap, and airsealed kneewalls.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    This case study describes a DOE Zero Energy Ready Home in Boulder, Colorado, that scored HERS 38 without PV and 0 with PV. This 2,504 ft2 custom home has advanced framed walls, superior insulation a ground-source heat pump, ERV, and triple-pane windows.

  5. The Optimal Level of Insulation in a Home Attic

    ERIC Educational Resources Information Center

    Martin, Paul; Premadasa, Kirthi

    2012-01-01

    The project models the conductive heat loss through the ceiling of a home. Students are led through a sequence of tasks from measuring the area and insulation status of a home to developing several functions leading to a net savings function where the depth of insulation is the input. At this point students use calculus or a graphing utility to…

  6. 24 CFR 3280.511 - Comfort cooling certificate and information.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... amount of exposure of the windows to the sun's radiant heat. Therefore, the home's heat gains will vary dependent upon its orientation to the sun and any permanent shading provided. Information concerning the...

  7. 24 CFR 3280.511 - Comfort cooling certificate and information.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... amount of exposure of the windows to the sun's radiant heat. Therefore, the home's heat gains will vary dependent upon its orientation to the sun and any permanent shading provided. Information concerning the...

  8. 24 CFR 3280.511 - Comfort cooling certificate and information.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... amount of exposure of the windows to the sun's radiant heat. Therefore, the home's heat gains will vary dependent upon its orientation to the sun and any permanent shading provided. Information concerning the...

  9. Field Investigation of an Air-Source Cold Climate Heat Pump

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, Bo; Abdelaziz, Omar; Rice, C Keith

    In the U.S., there are approximately 2.6 million dwellings that use electricity for heating in cold and very cold regions with an annual energy consumption of 0.16 quads (0.17 EJ). A high performance cold climate heat pump (CCHP) would result in significant savings over current technologies (greater than 60% compared to electric resistance heating). We developed an air-source cold climate heat pump, which uses tandem compressors, with a single compressor rated for the building design cooling load, and running two compressors to provide, at -13 F (-25 C), 75% of rated heating capacity. The tandem compressors were optimized for heatingmore » operation and are able to tolerate discharge temperatures up to 280 F (138 C). A field investigation was conducted in the winter of 2015, in an occupied home in Ohio, USA. During the heating season, the seasonal COP was measured at 3.16, and the heat pump was able to operate down to -13 F (-25 C) and eliminate resistance heat use. The heat pump maintained an acceptable comfort level throughout the heating season. In comparison to a previous single-speed heat pump in the home, the CCHP demonstrated more than 40% energy savings in the peak heating load month. This paper illustrates the measured field performance, including compressor run time, frost/defrosting operations, distributions of building heating load and capacity delivery, comfort level, field measured COPs, etc.« less

  10. Solar Energy and You.

    ERIC Educational Resources Information Center

    Conservation and Renewable Energy Inquiry and Referral Service (DOE), Silver Spring, MD.

    This booklet provides an introduction to solar energy by discussing: (1) how a home is heated; (2) how solar energy can help in the heating process; (3) the characteristics of passive solar houses; (4) the characteristics of active solar houses; (5) how solar heat is stored; and (6) other uses of solar energy. Also provided are 10 questions to…

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neuhauser, K.; Gates, C.

    This research project evaluates post-retrofit performance measurements, energy use data and construction costs for 13 projects that participated in the National Grid Deep Energy Retrofit Pilot program. The projects implemented a package of measures defined by performance targets for building enclosure components and building enclosure air tightness. Nearly all of the homes reached a post-retrofit air tightness result of 1.5 ACH 50. Homes that used the chainsaw retrofit technique along with roof insulation, and wall insulation applied to the exterior had the best air tightness results and the lowest heating and cooling source energy use. Analysis of measure costs andmore » project objectives yielded a categorization of costs relative to energy performance objectives. On average about ½ of the energy-related measure costs correspond primarily to energy-related objectives, and 20% of energy-related measure costs relate primarily to non-energy objectives.« less

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gates, C.; Neuhauser, K.

    This research project evaluates post-retrofit performance measurements, energy use data and construction costs for 13 projects that participated in the National Grid Deep Energy Retrofit Pilot program. The projects implemented a package of measures defined by performance targets for building enclosure components and building enclosure air tightness. Nearly all of the homes reached a post-retrofit air tightness result of 1.5 ACH 50. Homes that used the chainsaw retrofit technique along with roof insulation, and wall insulation applied to the exterior had the best air tightness results and the lowest heating and cooling source energy use. Analysis of measure costs andmore » project objectives yielded a categorization of costs relative to energy performance objectives. On average about 1/2 of the energy-related measure costs correspond primarily to energy-related objectives, and 20% of energy-related measure costs relate primarily to non-energy objectives.« less

  13. Solar-heating and cooling system design package

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Package of information includes design data, performance specifications, drawings, hazard analysis, and spare parts list for commercially produced system installed in single-family dwelling in Akron, Ohio. System uses air flat-plate collectors, 12000 kg rock storage and backup heat pump. Solar portion requires 0.7 kW, and provides 35% of average total heating load including hot water. Information aids persons considering installing solar home-heating systems.

  14. Effect of flash-heat treatment on immunoglobulins in breast milk.

    PubMed

    Chantry, Caroline J; Israel-Ballard, Kiersten; Moldoveanu, Zina; Peerson, Jan; Coutsoudis, Anna; Sibeko, Lindiwe; Abrams, Barbara

    2009-07-01

    Heat-treated expressed breast milk is recommended by the World Health Organization as an option to reduce vertical HIV transmission in resource-poor regions. Flash-heat (FH) is a low technology pasteurization method developed for home use, but its effect on quantity and quality of breast milk immunoglobulins is unknown. To evaluate FH's effect on breast milk immunoglobulin levels and antigen-binding capacity. Fifty HIV+ mothers in South Africa provided breast milk. Part of each sample served as an unheated control; the remainder was flash-heated. Total and antigen-specific immunoglobulin A (IgA) and immunoglobulin G (IgG) were measured by enzyme-linked immunosorbent assay. Paired t test was performed on log-transformed data. FH significantly decreased total IgA and IgG concentrations [geometric mean (geometric SD) 318.0 (1.9) vs. 398.2 (1.9) microg/mL and 89.1 (2.7) vs. 133.3 (2.5) microg/mL, P < 0.001 each]. Similar decreases in anti-HIV-1 gp120 IgG, anti-pneumococcal polysaccharide, and anti-poliovirus IgA occurred (P < 0.001 each). Although the latter was most affected, FH retained 66% of the antigen-binding ability. In contrast, binding capacity of IgA and IgG to influenza increased after FH (P = 0.029 and 0.025, respectively). Most breast milk immunoglobulin activity survives FH, suggesting flash-heated breast milk is immunologically superior to breast milk substitutes. Clinical significance of this decreased immunoglobulin activity needs evaluation in prospective trials.

  15. Effect of Flash-heat Treatment on Immunoglobulins in Breastmilk

    PubMed Central

    Chantry, Caroline J.; Israel-Ballard, Kiersten; Moldoveanu, Zina; Peerson, Jan; Coutsoudis, Anna; Sibeko, Lindiwe; Abrams, Barbara

    2009-01-01

    Background Heat-treated expressed breastmilk is recommended by WHO as an option to reduce vertical HIV transmission in resource poor regions. Flash-heat (FH) is a low technology pasteurization method developed for home use, but its effect on quantity and quality of breastmilk immunoglobulins is unknown. Objective To evaluate FH's effect on breastmilk immunoglobulin levels and antigen binding capacity. Design/Methods Fifty HIV+ mothers in South Africa provided breastmilk. Part of each sample served as an unheated (UH) control; the remainder was Flash-heated. Total and antigen-specific IgA and IgG were measured by ELISA. Paired t-test was performed on log transformed data. Results FH significantly decreased total IgA and IgG concentrations [geometric mean (geometric sd) 318.0 (1.9) vs. 398.2 (1.9) mcg/mL and 89.1 (2.7) vs. 133.3 (2.5) mcg/mL, p<0.001 each]. Similar decreases in anti-HIV-1 gp120 IgG, anti-pneumococcal polysaccharide and anti-poliovirus IgA occurred (p<0.001 each). Although the latter was most affected, FH retained 66% of the antigen binding ability. In contrast, binding capacity of IgA and IgG to influenza increased after FH (p=0.029 and 0.025 respectively). Conclusions Most breastmilk immunoglobulin activity survives FH, suggesting Flash-heated breastmilk is immunologically superior to breastmilk substitutes. Clinical significance of this decreased immunoglobulin activity needs evaluation in prospective trials. PMID:19421069

  16. Solar powered absorption cycle heat pump using phase change materials for energy storage

    NASA Technical Reports Server (NTRS)

    Middleton, R. L.

    1972-01-01

    Solar powered heating and cooling system with possible application to residential homes is described. Operating principles of system are defined and illustration of typical energy storage and exchange system is provided.

  17. Making the Most of Your Energy Dollars in Home Heating & Cooling. NBS Consumer Information Series 8.

    ERIC Educational Resources Information Center

    Jacobs, Madeleine; Petersen, Stephen R.

    This pamphlet is a homeowner's guide to home weatherization. It provides a step-by-step energy audit that anyone can use to help determine the insulation needs of their home. This is not a "how-to-do-it" booklet, but is a guide by which homeowners can determine the best combination of improvements for their house, climate, and fuel…

  18. DOE ZERH Case Study: Carl Franklin Homes, L.C./Green Extreme Homes, CDC, McKinley Project, Garland TX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    Case study of a DOE 2015 Housing Innovation Award winning affordable home in the hot-humid climate that got a HERS 56 without PV or HERS 26 with PV, with 4.5” SIP walls and 8.5” SIP roof; uninsulated slab; ductless minisplit heat pump 15.5 SEER, and tankless hot water.

  19. DOE Zero Energy Ready Home Case Study: Caldwell and Johnson — Church Community and Housing Corporation, Charlestown, RI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2014-09-01

    This DOE Zero Energy Ready Home garnered an Affordable Builder award in the 2014 Housing Innovation Awards, for its highly insulated construction, minisplit heat pump and water heater, and triple pane windows.

  20. NREL Hosts Free Workshop on Winterizing Your Home

    Science.gov Websites

    Energy Laboratory (NREL) will describe ways to cut your utility bills this winter at a free workshop Oct strategies to keep the heat where it belongs - inside your home. Who: The workshop is free and open to the

  1. Take-Home Experiments for Large Lecture Classes.

    ERIC Educational Resources Information Center

    Johnston, Bradley G.; Schroeer, Juergen M.

    1992-01-01

    Suggests seven take-home experiments geared toward the topic of energy that can be utilized in large, general-education physics classes that do not include laboratory sessions. An appendix provides details for the experiment to measure the heat of fusion of water. (MDH)

  2. Monitoring of carbon monoxide in residences with bulk wood pellet storage in the Northeast United States.

    PubMed

    Rossner, Alan; Jordan, Carolyn E; Wake, Cameron; Soto-Garcia, Lydia

    2017-10-01

    The interest in biomass fuel is continuing to expand globally and in the northeastern United States as wood pellets are becoming a primary source of fuel for residential and small commercial systems. Wood pellets for boilers are often stored in basement storage rooms or large bag-type containers. Due to the enclosed nature of these storage areas, the atmosphere may exhibit increased levels of carbon monoxide. Serious accidents in Europe have been reported over the last decade in which high concentrations of carbon monoxide (CO) have been found in or near bulk pellet storage containers. The aim of this study was to characterize the CO concentrations in areas with indoor storage of bulk wood pellets. Data was obtained over approximately 7 months (December 2013 to June 2014) at 25 sites in New Hampshire and Massachusetts: 16 homes using wood pellet boilers with indoor pellet storage containers greater than or equal to 3 ton capacity; 4 homes with wood pellet heating systems with outdoor pellet storage; 4 homes using other heating fuels; and a university laboratory site. CO monitors were set up in homes to collect concentrations of CO in the immediate vicinity of wood pellet storage containers, and data were then compared to those of homes using fossil fuel systems. The homes monitored in this study provided a diverse set of housing stock spanning two and a half centuries of construction, with homes built from 1774 to 2013, representing a range of air exchange rates. The CO concentration data from each home was averaged hourly and then compared to a threshold of 9 ppm. While concentrations of CO were generally low for the homes studied, the need to properly design storage locations for pellets is and will remain a necessary component of wood pellet heating systems to minimize the risk of CO exposure. This paper is an assessment of carbon monoxide (CO) exposure from bulk wood pellet storage in homes in New Hampshire and Massachusetts. Understanding the CO concentrations in homes allows for better designs for storage bins and ventilation for storage areas. Hence, uniform policies for stored wood pellets in homes, schools, and businesses can be framed to ensure occupant safety. Currently in New York State rebates for the installation of wood pellet boilers are only provided if the bulk pellet storage is outside of the home, yet states such as New Hampshire, Vermont, and Maine currently do not have these restrictions.

  3. Effectiveness of interventions to reduce indoor air pollution and/or improve health in homes using solid fuel in lower and middle income countries: protocol for a systematic review.

    PubMed

    Quansah, Reginald; Ochieng, Caroline A; Semple, Sean; Juvekar, Sanjar; Emina, Jacques; Armah, Frederick Ato; Luginaah, Isaac

    2015-03-04

    Indoor air pollution (IAP) interventions are widely promoted as a means of reducing indoor air pollution/health from solid fuel use; and research addressing impact of these interventions has increased substantially in the past two decades. It is timely and important to understand more about effectiveness of these interventions. We describe the protocol of a systematic review to (i) evaluate effectiveness of IAP interventions to improve indoor air quality and/or health in homes using solid fuel for cooking and/or heating in lower- and middle-income countries, (ii) identify the most effective intervention to improve indoor air quality and/or health, and (iii) identify future research needs. This review will be conducted according to the National Institute for Health and Care Excellence (NICE) guidelines and will be reported following the PRISMA statement. Ovid MEDLINE, Ovid Embase, SCOPUS, and PubMed searches were conducted in September 2013 and updated in November 2014 (and include any further search updates in February 2015). Additional references will be located through searching the references cited by identified studies and through the World Health Organization Global database of household air pollution measurements. We will also search our own archives. Data extraction and risk of bias assessment of all included papers will be conducted independently by five reviewers. The study will provide insights into what interventions are most effective in reducing indoor air pollution and/or adverse health outcomes in homes using solid fuel for cooking or heating in lower- or middle-income countries. The findings from this review will be used to inform future IAP interventions and policy on poverty reduction and health improvement in poor communities who rely on biomass and solid fuels for cooking and heating. The review has been registered with PROSPERO (registration number CRD42014009768 ).

  4. Visual Analytics for Pattern Discovery in Home Care

    PubMed Central

    Monsen, Karen A.; Bae, Sung-Heui; Zhang, Wenhui

    2016-01-01

    Summary Background Visualization can reduce the cognitive load of information, allowing users to easily interpret and assess large amounts of data. The purpose of our study was to examine home health data using visual analysis techniques to discover clinically salient associations between patient characteristics with problem-oriented health outcomes of older adult home health patients during the home health service period. Methods Knowledge, Behavior and Status ratings at discharge as well as change from admission to discharge that was coded using the Omaha System was collected from a dataset on 988 de-identified patient data from 15 home health agencies. SPSS Visualization Designer v1.0 was used to visually analyze patterns between independent and outcome variables using heat maps and histograms. Visualizations suggesting clinical salience were tested for significance using correlation analysis. Results The mean age of the patients was 80 years, with the majority female (66%). Of the 150 visualizations, 69 potentially meaningful patterns were statistically evaluated through bivariate associations, revealing 21 significant associations. Further, 14 associations between episode length and Charlson co-morbidity index mainly with urinary related diagnoses and problems remained significant after adjustment analyses. Through visual analysis, the adverse association of the longer home health episode length and higher Charlson co-morbidity index with behavior or status outcomes for patients with impaired urinary function was revealed. Conclusions We have demonstrated the use of visual analysis to discover novel patterns that described high-needs subgroups among the older home health patient population. The effective presentation of these data patterns can allow clinicians to identify areas of patient improvement, and time periods that are most effective for implementing home health interventions to improve patient outcomes. PMID:27466053

  5. Enhancing ventilation in homes of children with asthma: cost-effectiveness study alongside randomised controlled trial

    PubMed Central

    Edwards, Rhiannon T; Neal, Richard D; Linck, Pat; Bruce, Nigel; Mullock, Linda; Nelhans, Nick; Pasterfield, Diana; Russell, Daphne; Russell, Ian; Woodfine, Louise

    2011-01-01

    Background There has been little rigorous economic analysis of the relationship between asthma and improved housing. Aim To evaluate the cost-effectiveness of installing ventilation systems, and central heating if necessary, in homes of children with ‘moderate’ or ‘severe’ asthma. Design and setting An incremental cost-effectiveness analysis alongside a pragmatic randomised controlled trial of a tailored package of housing modifications designed to improve ventilation and household heating in homes within Wrexham County Borough, Wales, UK. Method A total of 177 children aged between 5 and 14 years, identified from general practice registers, were studied. Parents reported on the quality of life of their children over a 12-month period. General practices reported on health-service resources used by those children, and their asthma-related prescriptions, over the same period. Results The tailored package shifted 17% of children in the intervention group from ‘severe’ to ‘moderate’ asthma, compared with a 3% shift in the control group. The mean cost of these modifications was £1718 per child treated or £12300 per child shifted from ‘severe’ to ‘moderate’. Healthcare costs over 12 months following randomisation did not differ significantly between intervention and control groups. Bootstrapping gave an incremental cost-effectiveness ratio (ICER) of £234 per point improvement on the 100-point PedsQL™ asthma-specific scale, with 95% confidence interval (CI) = £140 to £590. The ICER fell to £165 (95% CI = £84 to £424) for children with ‘severe’ asthma. Conclusion This novel and pragmatic trial, with integrated economic evaluation, reported that tailored improvement of the housing of children with moderate to severe asthma is likely to be a cost-effective use of public resources. This is a rare example of evidence for collaboration between local government and the NHS. PMID:22054337

  6. Slash Your Energy Bills.

    ERIC Educational Resources Information Center

    Lawrence, Allen

    Tips are given here for energy conservation in the home. Included are heating and cooling houses, water heating, bathing, clothes washing and drying, cooking, refrigerating, dishwashing, lighting, and driving. Also included is a table of annual energy requirements of household electric appliances. (BB)

  7. SOLAR THERMAL HEATING SYSTEM FOR A ZERO ENERGY HOUSE

    EPA Science Inventory

    Technical Challenge to Sustainability: The inter-disciplinary team, Pittsburgh Synergy, plans to design and build an 800sf home powered by site-based solar energy systems for the 2005 Solar Decathlon. The house employs a home-based business and related transportation needs,...

  8. Transformations, Inc.: Partnering to Build Net-Zero Energy Houses in Massachusetts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ueno, K.; Bergey, D.; Wytrykowska, H.

    Transformations, Inc. is a residential development and building company that has partnered with Building Science Corporation to build new construction net-zero energy houses in Massachusetts under the Building America program. There are three communities that will be constructed through this partnership: Devens Sustainable Housing ('Devens'), The Homes at Easthampton Meadow ('Easthampton') andPhase II of the Coppersmith Way Development ('Townsend'). This report intends to cover all of the single-family new construction homes that have been completed to date. The houses built in these developments are net zero energy homes built in a cold climate. They will contribute to finding answers tomore » specific research questions for homes with high R double stud walls and high efficiency ductlessair source heat pump systems ('mini-splits'); allow to explore topics related to the financing of photovoltaic systems and basements vs. slab-on-grade construction; and provide feedback related to the performance of ductless mini-split air source heat pumps.« less

  9. Transformations, Inc.. Partnering To Build Net-Zero Energy Houses in Massachusetts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ueno, K.; Bergey, D.; Wytrykowska, H.

    Transformations, Inc. is a residential development and building company that has partnered with Building Science Corporation to build new construction net-zero energy houses in Massachusetts under the Building America program. There are three communities that will be constructed through this partnership: Devens Sustainable Housing ("Devens"), The Homes at Easthampton Meadow ("Easthampton") and Phase II of the Coppersmith Way Development ("Townsend"). This report intends to cover all of the single-family new construction homes that have been completed to date. The houses built in these developments are net zero energy homes built in a cold climate. They will contribute to finding answersmore » to specific research questions for homes with high R double stud walls and high efficiency ductless air source heat pump systems ("mini-splits"); allow to explore topics related to the financing of photovoltaic systems and basements vs. slab-on-grade construction; and provide feedback related to the performance of ductless mini-split air source heat pumps.« less

  10. Making Work: Demonstrating Thermodynamic Concepts with Solar-Powered Wax and Rubber Heat Engines

    ERIC Educational Resources Information Center

    Appleyard, S. J.

    2007-01-01

    Construction details are provided for simple heat engines that use candle wax and elastomers as working substances. The engines are constructed using common household materials and can be easily constructed in a school classroom or at home. They work reliably and are useful tools for demonstrating the conversion of heat to mechanical work. They…

  11. 16 CFR Appendix D5 to Part 305 - Water Heaters-Heat Pump

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Water Heaters-Heat Pump D5 Appendix D5 to... CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER... Appendix D5 to Part 305—Water Heaters—Heat Pump Range Information CAPACITY FIRST HOUR RATING Range of...

  12. 16 CFR Appendix D5 to Part 305 - Water Heaters-Heat Pump

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Water Heaters-Heat Pump D5 Appendix D5 to... CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER... Appendix D5 to Part 305—Water Heaters—Heat Pump Range Information CAPACITY FIRST HOUR RATING Range of...

  13. Home retrofitting for energy conservation and solar considerations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-10-01

    This manual explains both the key concepts behind our need for and our impact on energy usage, as well as a nuts-and-bolts explanation of how to improve the energy efficiency of your home. By reviewing both the concepts and practices of energy conservation, the manual presents a comprehensive picture of how home energy use is effected by the inhabitants and by the structure itself. The manual begins with an explanation of why we are looking at energy, then proceeds to explain how the heat transfer occurs between houses and humans. Next is a chapter on energy audits and how tomore » use them, followed by a comprehensive section on energy conservation actions to do now to reduce energy use. Conservation actions include low cost/no cost measures, schemes to reduce infiltration, how to increase insulation, and what to do with windows and doors, heating and heat distribution systems, and water heaters. Solar energy options are then briefly explained, as well as the all important issues of financing and tax credits. The manual concludes with a bibliography to direct the reader to more sources of information.« less

  14. The relation between respiratory illness in primary schoolchildren and the use of gas for cooking--II. Factors affecting nitrogen dioxide levels in the home.

    PubMed

    Goldstein, B D; Melia, R J; Chinn, S; Florey, C V; Clark, D; John, H H

    1979-12-01

    The study was designed to determine whether there was an association between indoor levels of nitrogen dioxide (NO2) and respiratory illness and lung function in schoolchildren. NO2 was measured for one week in the winter outside and inside the homes of children aged 6-7 years living and attending primary schools in a defined 4 square km area in Middlesbrough, Cleveland, UK. Outdoor levels of NO2 measured at 75 points within the area ranged from 14-24 ppb weekly average. Measurements were also made in 428 kitchens with gas cookers, range 5-317 ppb, mean 112.2 ppb, and in 87 kitchens with electric cookers, range 6-188 ppb, mean 18.0 ppb. In a random subsample of homes the range of NO2 levels in 107 children's bedrooms in homes where gas was used for cooking was 4-169 ppb, mean 30.5 ppb, in 18 bedrooms in electric cooking homes the range was 3-37 ppb, mean 13.9 ppb. NO2 levels in the gas cooking kitchens were positively related to the presence of pilot lights, use of gas fires for main heating, number of regular smokers, and the number of people in the home. Information from 29 homes with the highest kitchen NO2 levels paired with 29 low NO2 gas cooking homes showed that the daily number of meals eaten and the frequency with which the cooker was used for heating and drying clothes were significantly greater in the high NO2 homes.

  15. Banks of lights dry tiles on Atlantis

    NASA Technical Reports Server (NTRS)

    2001-01-01

    KENNEDY SPACE CENTER, Fla. -- In the Orbiter Processing Facility, a worker points to some of the tiles on orbiter Atlantis that are being dried by clusters of 200-300 watt heat lamps. Significant rainstorms during the orbiter'''s turnaround for a ferry flight home from Edwards Air Force Base, Calif., caused a moisture problem. The tiles are part of the Thermal Protection System used on orbiters for extreme temperatures encountered during landing. Engineers are evaluating the current procedures to assure the tiles are in a safe and flight-ready condition.

  16. An assessment of efficient water heating options for an all-electric single family residence in a mixed-humid climate.

    PubMed

    Balke, Elizabeth C; Healy, William M; Ullah, Tania

    2016-12-01

    An evaluation of a variety of efficient water heating strategies for an all-electric single family home located in a mixed-humid climate is conducted using numerical modeling. The strategies considered include various combinations of solar thermal, heat pump, and electric resistance water heaters. The numerical model used in the study is first validated against a year of field data obtained on a dual-tank system with a solar thermal preheat tank feeding a heat pump water heater that serves as a backup. Modeling results show that this configuration is the most efficient of the systems studied over the course of a year, with a system coefficient of performance (COP sys ) of 2.87. The heat pump water heater alone results in a COP sys of 1.9, while the baseline resistance water heater has a COP sys of 0.95. Impacts on space conditioning are also investigated by considering the extra energy consumption required of the air source heat pump to remove or add heat from the conditioned space by the water heating system. A modified COP sys that incorporates the heat pump energy consumption shows a significant drop in efficiency for the dual tank configuration since the heat pump water heater draws the most heat from the space in the heating season while the high temperatures in the solar storage tank during the cooling season result in an added heat load to the space. Despite this degradation in the COP sys , the combination of the solar thermal preheat tank and the heat pump water heater is the most efficient option even when considering the impacts on space conditioning.

  17. An assessment of efficient water heating options for an all-electric single family residence in a mixed-humid climate

    PubMed Central

    Balke, Elizabeth C.; Healy, William M.; Ullah, Tania

    2016-01-01

    An evaluation of a variety of efficient water heating strategies for an all-electric single family home located in a mixed-humid climate is conducted using numerical modeling. The strategies considered include various combinations of solar thermal, heat pump, and electric resistance water heaters. The numerical model used in the study is first validated against a year of field data obtained on a dual-tank system with a solar thermal preheat tank feeding a heat pump water heater that serves as a backup. Modeling results show that this configuration is the most efficient of the systems studied over the course of a year, with a system coefficient of performance (COPsys) of 2.87. The heat pump water heater alone results in a COPsys of 1.9, while the baseline resistance water heater has a COPsys of 0.95. Impacts on space conditioning are also investigated by considering the extra energy consumption required of the air source heat pump to remove or add heat from the conditioned space by the water heating system. A modified COPsys that incorporates the heat pump energy consumption shows a significant drop in efficiency for the dual tank configuration since the heat pump water heater draws the most heat from the space in the heating season while the high temperatures in the solar storage tank during the cooling season result in an added heat load to the space. Despite this degradation in the COPsys, the combination of the solar thermal preheat tank and the heat pump water heater is the most efficient option even when considering the impacts on space conditioning. PMID:27990058

  18. Temperature of gas delivered from ventilators.

    PubMed

    Chikata, Yusuke; Onodera, Mutsuo; Imanaka, Hideaki; Nishimura, Masaji

    2013-01-01

    Although heated humidifiers (HHs) are the most efficient humidifying device for mechanical ventilation, some HHs do not provide sufficient humidification when the inlet temperature to the water chamber is high. Because portable and home-care ventilators use turbines, blowers, pistons, or compressors to inhale in ambient air, they may have higher gas temperature than ventilators with piping systems. We carried out a bench study to investigate the temperature of gas delivered from portable and home-care ventilators, including the effects of distance from ventilator outlet, fraction of inspiratory oxygen (FIO2), and minute volume (MV). We evaluated five ventilators equipped with turbine, blower, piston, or compressor system. Ambient air temperature was adjusted to 24°C ± 0.5°C, and ventilation was set at FIO2 0.21, 0.6, and 1.0, at MV 5 and 10 L/min. We analyzed gas temperature at 0, 40, 80, and 120 cm from ventilator outlet and altered ventilator settings. While temperature varied according to ventilators, the outlet gas temperature of ventilators became stable after, at the most, 5 h. Gas temperature was 34.3°C ± 3.9°C at the ventilator outlet, 29.5°C ± 2.2°C after 40 cm, 25.4°C ± 1.2°C after 80 cm and 25.1°C ± 1.2°C after 120 cm (P < 0.01). FIO2 and MV did not affect gas temperature. Gas delivered from portable and home-care ventilator was not too hot to induce heated humidifier malfunctioning. Gas soon declined when passing through the limb.

  19. Field Evaluation of Programmable Thermostats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sachs, O.; Tiefenbeck, V.; Duvier, C.

    2012-12-01

    Prior research suggests that poor programmable thermostats usability may prevent their effective use to save energy. We hypothesized that home occupants with a high-usability thermostats would be more likely to use them to save energy than people with a basic thermostat. We randomly installed a high-usability thermostat in half the 77 apartments of an affordable housing complex, installing a basic thermostat in the other half. During the heating season, we collected space temperature and furnace on-off data to evaluate occupant interaction with the thermostats, foremost nighttime setbacks. We found that thermostat usability did not influence energy-saving behaviors, finding no significantmore » difference in temperature maintained among apartments with high- and low-usability thermostats.« less

  20. New Whole-House Solutions Case Study: John Wesley Miller, Tucson, Arizona

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    This builder worked with the National Association of Home Builders Research Center to build two net-zero energy homes with foam-sheathed masonry walls, low-E windows 2.9 ACH50 air sealing, transfer grilles, ducts in insulated attic, PV, and solar water heating.

  1. Energy Management Checklist for the Home.

    ERIC Educational Resources Information Center

    Pifer, Glenda

    This booklet contains a checklist of equipment and activities for the individual's use in home energy management. The categories covered include: (1) insulation; (2) windows; (3) temperature control; (4) lighting; (5) heating water; (6) laundry; (7) cleaning and maintenance; (8) cooking; (9) refrigeration; (10) dishwashing; (11) recreation; and…

  2. Insulated Concrete Homes Increase Durability and Energy Efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Building America; Hendron, B.; Poole, L.

    2001-06-05

    New houses designed by Mercedes Homes in Melbourne, Florida, with technical support from the U.S. Department of Energy's Building America Program, save their homeowners money by using energy efficient features such as a high performance heat pump and solar control glazing to reduce cooling costs.

  3. Evaluation of storing hepatitis B vaccine outside the cold chain in the Solomon Islands: Identifying opportunities and barriers to implementation.

    PubMed

    Breakwell, Lucy; Anga, Jenniffer; Dadari, Ibrahim; Sadr-Azodi, Nahad; Ogaoga, Divinal; Patel, Minal

    2017-05-15

    Monovalent Hepatitis B vaccine (HepB) is heat stable, making it suitable for storage outside cold chain (OCC) at 37°C for 1month. We conducted an OCC project in the Solomon Islands to determine the feasibility of and barriers to national implementation and to evaluate impact on coverage. Healthcare workers at 13 facilities maintained monovalent HepB birth dose (HepB-BD) OCC for up to 28days over 7months. Vaccination data were recorded for children born during the project and those born during 7months before the project. Timely HepB-BD coverage among facility and home births increased from 30% to 68% and from 4% to 24%, respectively. Temperature excursions above 37°C were rare, but vaccine wastage was high and shortages common. Storing HepB OCC can increase HepB-BD coverage in countries with insufficient cold chain capacity or numerous home births. High vaccine wastage and unreliable vaccine supply must be addressed for successful implementation. Published by Elsevier Ltd.

  4. Accomplishments of the American-Polish program for elimination of low emissions in Krakow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butcher, T.A.; Pierce, B.

    1998-12-31

    Since 1990 the US Department of Energy (DOE) has been involved in a program aimed at reducing air pollution caused by small, coal-fired sources in Poland. The activity is focused on the city of Cracow, Poland with the intention that results will be applicable and extendable to the entire region. The effort under this program has been focused into 5 main areas of interest as follows: (1) energy conservation and extension of central station district heating; (2) replacement of coal- and coke-fired boilers with natural gas-fired boilers; (3) replacement of coal-fired home stoves with electric heating appliances; (4) reduction ofmore » emissions from stoker-fired boiler houses; and (5) reduction of emissions from coal-fired home heating stoves.« less

  5. Retrofitting Forced Air Combi Systems: A Cold Climate Field Assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schoenbauer, Ben; Bohac, Dave; McAlpine, Jack

    This project analyzed combined condensing water heaters or boilers and hydronic air coils to provide high efficiency domestic hot water (DHW) and forced air space heating. Called "combi" systems, they provided similar space and water heating performance less expensively than installing two condensing appliances. The system's installed costs were cheaper than installing a condensing furnace and either a condensing tankless or condensing storage water heater. However, combi costs must mature and be reduced before they are competitive with a condensing furnace and power vented water heater (energy factor of 0.60). Better insulation and tighter envelopes are reducing space heating loadsmore » for new and existing homes. For many homes, decreased space heating loads make it possible for both space and domestic water heating loads to be provided with a single heating plant. These systems can also eliminate safety issues associated with natural draft appliances through the use of one common sealed combustion vent. The combined space and water heating approach was not a new idea. Past systems have used non-condensing heating plants, which limited their usefulness in climates with high heating loads. Previous laboratory work (Schoenbauer et al. 2012a) showed that proper installation was necessary to achieve condensing with high efficiency appliances. Careful consideration was paid to proper system sizing and minimizing the water temperature returning from the air handling unit to facilitate condensing operation.« less

  6. Retrofitting Forced Air Combi Systems: A Cold Climate Field Assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schoenbauer, Ben; Bohac, Dave; McAlpine, Jake

    This project analyzed combined condensing water heaters or boilers and hydronic air coils to provide high efficiency domestic hot water (DHW) and forced air space heating. Called 'combi' systems, they provided similar space and water heating performance less expensively than installing two condensing appliances. The system's installed costs were cheaper than installing a condensing furnace and either a condensing tankless or condensing storage water heater. However, combi costs must mature and be reduced before they are competitive with a condensing furnace and power vented water heater (energy factor of 0.60). Better insulation and tighter envelopes are reducing space heating loadsmore » for new and existing homes. For many homes, decreased space heating loads make it possible for both space and domestic water heating loads to be provided with a single heating plant. These systems can also eliminate safety issues associated with natural draft appliances through the use of one common sealed combustion vent. The combined space and water heating approach was not a new idea. Past systems have used non-condensing heating plants, which limited their usefulness in climates with high heating loads. Previous laboratory work (Schoenbauer et al. 2012a) showed that proper installation was necessary to achieve condensing with high efficiency appliances. Careful consideration was paid to proper system sizing and minimizing the water temperature returning from the air handling unit to facilitate condensing operation.« less

  7. KSC-2012-1066

    NASA Image and Video Library

    2012-01-18

    CAPE CANAVERAL, Fla. -- The stylized shape of the new home for Atlantis at the Kennedy Space Center Visitor Complex incorporates hues of orange and gold to represent both the heat and the bright colors of re-entry. Special gray-colored tiling has been incorporated into the building's design to represent the space shuttle tiles that protected the orbiter from the heat of re-entry. A groundbreaking ceremony for the future home of Atlantis was held Jan. 18. For more information on this and other exhibits at the visitor complex, go to http://www.kennedyspacecenter.com. Artist rendering courtesy of PGAV Destinations for Delaware North Parks & Resorts

  8. Measuring Building Insulation

    NASA Astrophysics Data System (ADS)

    Parks, Beth

    2013-03-01

    Currently, the only way for homeowners to learn about the effectiveness of their home insulation is to hire an energy auditor. This difficulty deters homeowners from taking action to improve energy efficiency. In principle, measuring the temperature difference between a wall surface and the interior of a home is sufficient to determine the wall insulation, but in practice, temperature cycles from the heating system make a single measurement unreliable. I will describe a simple and inexpensive thermocouple-based device to measure this temperature difference and report results obtained by monitoring this temperature difference over multiple heating cycles in a range of buildings. Patent application 12/555371

  9. Effects on carbon monoxide levels in mobile homes using unvented kerosene heaters for residential heating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, R.; Walsh, D.; White, J.

    1992-01-01

    Carbon monoxide (CO) emission levels were continuously monitored in 8 mobile trailer homes less than 10 years old. These homes were monitored in an US EPA study on indoor air quality as affected by unvented portable kerosene heaters. Respondents were asked to operate their heaters in a normal fashion. CO, air exchange and temperature values were measured during the study in each home. Results indicate that consumers using unvented kerosene heaters may be unknowingly exposed to high CO levels without taking proper precautions.

  10. Histamine as an emergent indoor contaminant: Accumulation and persistence in bed bug infested homes.

    PubMed

    DeVries, Zachary C; Santangelo, Richard G; Barbarin, Alexis M; Schal, Coby

    2018-01-01

    Histamine is used in bronchial and dermal provocation, but it is rarely considered an environmental risk factor in allergic disease. Because bed bugs defecate large amounts of histamine as a component of their aggregation pheromone, we sought to determine if histamine accumulates in household dust in bed bug infested homes, and the effects of bed bug eradication with spatial heat on histamine levels in dust. We collected dust in homes and analyzed for histamine before, and up to three months after bed bug eradication. Histamine levels in bed bug infested homes were remarkably high (mean = 54.6±18.9 μg/100 mg of sieved household dust) and significantly higher than in control homes not infested with bed bugs (mean < 2.5±1.9 μg/100 mg of sieved household dust). Heat treatments that eradicated the bed bug infestations failed to reduce histamine levels, even three months after treatment. We report a clear association between histamine levels in household dust and bed bug infestations. The high concentrations, persistence, and proximity to humans during sleep suggest that bed bug-produced histamine may represent an emergent contaminant and pose a serious health risk in the indoor environment.

  11. Histamine as an emergent indoor contaminant: Accumulation and persistence in bed bug infested homes

    PubMed Central

    Santangelo, Richard G.; Barbarin, Alexis M.; Schal, Coby

    2018-01-01

    Histamine is used in bronchial and dermal provocation, but it is rarely considered an environmental risk factor in allergic disease. Because bed bugs defecate large amounts of histamine as a component of their aggregation pheromone, we sought to determine if histamine accumulates in household dust in bed bug infested homes, and the effects of bed bug eradication with spatial heat on histamine levels in dust. We collected dust in homes and analyzed for histamine before, and up to three months after bed bug eradication. Histamine levels in bed bug infested homes were remarkably high (mean = 54.6±18.9 μg/100 mg of sieved household dust) and significantly higher than in control homes not infested with bed bugs (mean < 2.5±1.9 μg/100 mg of sieved household dust). Heat treatments that eradicated the bed bug infestations failed to reduce histamine levels, even three months after treatment. We report a clear association between histamine levels in household dust and bed bug infestations. The high concentrations, persistence, and proximity to humans during sleep suggest that bed bug-produced histamine may represent an emergent contaminant and pose a serious health risk in the indoor environment. PMID:29432483

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Logue, Jennifer M; Singer, Brett

    Range hood use during residential cooking is essential to maintaining good indoor air quality. However, widespread use will impact the energy demand of the U.S. housing stock. This paper describes a modeling study to determine site energy, source energy, and consumer costs for comprehensive range hood use. To estimate the energy impacts for all 113 million homes in the U.S., we extrapolated from the simulation of a representative weighted sample of 50,000 virtual homes developed from the 2009 Residential Energy Consumption Survey database. A physics-based simulation model that considered fan energy, energy to condition additional incoming air, and the effectmore » on home heating and cooling due to exhausting the heat from cooking was applied to each home. Hoods performing at a level common to hoods currently in U.S. homes would require 19?33 TWh [69?120 PJ] of site energy, 31?53 TWh [110-190 PJ] of source energy; and would cost consumers $1.2?2.1 billion (U.S.$2010) annually in the U.S. housing stock. The average household would spend less than $15 annually. Reducing required airflow, e.g. with designs that promote better pollutant capture has more energy saving potential, on average, than improving fan efficiency.« less

  13. Datasets for Ostrava PMF paper

    EPA Pesticide Factsheets

    These data support a published journal paper described as follows:A 14-week investigation during a warm and cold seasons was conducted to improve understanding of airpollution sources that might be impacting air quality in Ostrava, the Czech Republic. Fine particulatematter (PM2.5) samples were collected in consecutive 12-h day and night increments during spring andfall 2012 sampling campaigns. Sampling sites were strategically located to evaluate conditions in closeproximity of a large steel works industrial complex, as well as away from direct influence of theindustrial complex. These samples were analyzed for metals and other elements, organic and elemental(black) carbon, and polycyclic aromatic hydrocarbons (PAHs). The PM2.5 samples were supplementedwith pollutant gases and meteorological parameters. We applied the EPA PMF v5.1 model with uncertainty estimate features to the Ostrava data set. Using the model's bootstrapping procedure and other considerations, six factors were determined to provide the optimum solution. Each model run consisted of 100 iterations to ensure that the solution represents a global minimum. The resulting factors were identified as representing coal (power plants), mixed Cl, crustal, industrial 1 (alkali metals and PAHs), industrial 2 (transition metals), and home heat/transportation. The home heating source is thought to be largely domestic boilers burning low quality fuels such as lignite, wood, and domestic waste.Transportation-r

  14. Do Heat Pump Clothes Dryers Make Sense for the U.S. Market

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meyers, Steve; Franco, Victor; Lekov, Alex

    Heat pump clothes dryers (HPCDs) can be as much as 50percent more energy-efficient than conventional electric resistance clothes dryers, and therefore have the potential to save substantial amounts of electricity. While not currently available in the U.S., there are manufacturers in Europe and Japan that produce units for those markets. Drawing on analysis conducted for the U.S. Department of Energy's (DOE) current rulemaking on amended standards for clothes dryers, this paper evaluates the cost-effectiveness of HPCDs in American homes, as well as the national impact analysis for different market share scenarios. In order to get an accurate measurement of realmore » energy savings potential, the paper offers a new energy use calculation methodology that takes into account the most current data on clothes washer cycles, clothes dryer usage frequency, remaining moisture content, and load weight per cycle, which is very different from current test procedure values. Using the above methodology along with product cost estimates developed by DOE, the paper presents the results of a life-cycle cost analysis of the adoption of HPCDs in a representative sample of American homes. The results show that HPCDs have positive economic benefits only for households with high clothes dryer usage or for households with high electricity prices and moderately high utilization.« less

  15. Householder's Perceptions of Insulation Adequacy and Drafts in the Home in 2001

    EIA Publications

    2004-01-01

    In order to improve the estimation of end-use heating consumption, the Energy Information Administration's (EIA), 2001 Residential Energy Consumption Survey (RECS), for the first time, asked respondents to judge how drafty they perceived their homes to be as a measure of insulation quality.

  16. 76 FR 50218 - Agency Information Collection Activities; Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-12

    ... about the thermal performance characteristics of home insulation products. The R-value of an insulation signifies the insulation's degree of resistance to the flow of heat. This information tells consumers how... the FTC rule on ``Labeling and Advertising of Home Insulation'' (R-value Rule or Rule). That clearance...

  17. ORGANIC COMBUSTION FINGERPRINTS OF THREE COMMON HOME HEATING FUELS

    EPA Science Inventory

    The paper discusses the chemical structures of three common home eating fuels: wood, coal, and No. 2 fuel oil. GC and GC/MS data are then presented which demonstrate how the thermal destruction of each fuel results in the production of a characteristic group of organic "fingerpri...

  18. How Solar Energy Can Work for You

    ERIC Educational Resources Information Center

    Iker, Sam

    1978-01-01

    The future of solar heated homes looks bright. The increase in availability of solar hardware and information along with tax credits point to an increase in both solar water and space heating. Solar systems can add to the value of a house. (BB)

  19. Hydronic Heating Coil Versus Propane Furnace, Rehoboth Beach, Delaware (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    2014-01-01

    Insight Homes constructed two houses in Rehoboth Beach, Delaware, with identical floor plans and thermal envelopes but different heating and domestic hot water (DHW) systems. Each house is 1,715-ft 2 with a single story, three bedrooms, two bathrooms, and the heating, ventilation, and air conditioning (HVAC) systems and ductwork located in conditioned crawlspaces. The standard house, which the builder offers as its standard production house, uses an air source heat pump (ASHP) with supplemental propane furnace heating. The Building America test house uses the same ASHP unit with supplemental heat provided by the DHW heater (a combined DHW and hydronicmore » heating system, where the hydronic heating element is in the air handler). Both houses were occupied during the test period. Results indicate that efficiency of the two heating systems was not significantly different. Three issues dominate these results; lower system design performance resulting from the indoor refrigerant coil selected for the standard house, an incorrectly functioning defrost cycle in the standard house, and the low resolution of the natural gas monitoring equipment. The thermal comfort of both houses fell outside the ASHRAE Standard 55 heating range but was within the ACCA room-to-room temperature range when compared to the thermostat temperature. The monitored DHW draw schedules were input into EnergyPlus to evaluate the efficiency of the tankless hot water heater model using the two monitored profiles and the Building America House Simulation Protocols. The results indicate that the simulation is not significantly impacted by the draw profiles.« less

  20. Evaluating the Long-Term Health and Economic Impacts of Central Residential Air Filtration for Reducing Premature Mortality Associated with Indoor Fine Particulate Matter (PM2.5) of Outdoor Origin

    PubMed Central

    Zhao, Dan; Azimi, Parham; Stephens, Brent

    2015-01-01

    Much of human exposure to fine particulate matter (PM2.5) of outdoor origin occurs in residences. High-efficiency particle air filtration in central heating, ventilating, and air-conditioning (HVAC) systems is increasingly being used to reduce concentrations of particulate matter inside homes. However, questions remain about the effectiveness of filtration for reducing exposures to PM2.5 of outdoor origin and adverse health outcomes. Here we integrate epidemiology functions and mass balance modeling to estimate the long-term health and economic impacts of HVAC filtration for reducing premature mortality associated with indoor PM2.5 of outdoor origin in residences. We evaluate 11 classifications of filters (MERV 5 through HEPA) using six case studies of single-family home vintages and ventilation system combinations located in 22 U.S. cities. We estimate that widespread use of higher efficiency filters would reduce premature mortality by 0.002–2.5% and increase life expectancy by 0.02–1.6 months, yielding annual monetary benefits ranging from $1 to $1348 per person in the homes and locations modeled herein. Large differences in the magnitude of health and economic impacts are driven largely by differences in rated filter efficiency and building and ventilation system characteristics that govern particle infiltration and persistence, with smaller influences attributable to geographic location. PMID:26197328

  1. Evaluating the Long-Term Health and Economic Impacts of Central Residential Air Filtration for Reducing Premature Mortality Associated with Indoor Fine Particulate Matter (PM2.5) of Outdoor Origin.

    PubMed

    Zhao, Dan; Azimi, Parham; Stephens, Brent

    2015-07-21

    Much of human exposure to fine particulate matter (PM2.5) of outdoor origin occurs in residences. High-efficiency particle air filtration in central heating, ventilating, and air-conditioning (HVAC) systems is increasingly being used to reduce concentrations of particulate matter inside homes. However, questions remain about the effectiveness of filtration for reducing exposures to PM2.5 of outdoor origin and adverse health outcomes. Here we integrate epidemiology functions and mass balance modeling to estimate the long-term health and economic impacts of HVAC filtration for reducing premature mortality associated with indoor PM2.5 of outdoor origin in residences. We evaluate 11 classifications of filters (MERV 5 through HEPA) using six case studies of single-family home vintages and ventilation system combinations located in 22 U.S. cities. We estimate that widespread use of higher efficiency filters would reduce premature mortality by 0.002-2.5% and increase life expectancy by 0.02-1.6 months, yielding annual monetary benefits ranging from $1 to $1348 per person in the homes and locations modeled herein. Large differences in the magnitude of health and economic impacts are driven largely by differences in rated filter efficiency and building and ventilation system characteristics that govern particle infiltration and persistence, with smaller influences attributable to geographic location.

  2. Best Practices Case Study: John Wesley Miller Companies - Armory Park Del Sol, Tucson, AZ

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Case study of John Wesley Miller Companies, who built two net zero energy homes plus 97 other solar homes in Tucson, AZ. Masonry block walls with rigid foam exterior sheathing, rigid foam over the roof deck plus R-38 in the attic, ducts in conditioned space, 4.2 kW and 5.7 kW photovoltaics and solar water heating yielded HERS scores of 0 on the two homes.

  3. Assessment of Thermal Comfort in a Building Heated with a Tiled Fireplace with the Function of Heat Accumulation

    NASA Astrophysics Data System (ADS)

    Telejko, Marek; Zender-Świercz, Ewa

    2017-10-01

    Thermal comfort determines the state of satisfaction of a person or group of people with thermal conditions of the environment in which the person or group of persons is staying. This state of satisfaction depends on the balance between the amount of heat generated by the body’s metabolism, and the dissipation of heat from the body to the surrounding environment. Due to differences in body build, metabolism, clothing etc. individuals may feel the parameters of the environment in which they are staying differently. Therefore, it is impossible to ensure the thermal comfort of all users of the room. However, properly designed building systems (heating, ventilation, air conditioning) allow for creating optimal thermal conditions that will evaluated positively by the vast majority of users. Due to the fact that currently we spend even 100% of the day indoors, the subject becomes extremely important. The article presents the evaluation of thermal comfort in rooms heated with a tiled fireplace with the function of accumulation of heat using the PMV (Predicted Mean Vote) and PPD (Predicted Percentage Dissatisfied) indices. It also presents the results of studies, on the quality of the micro-climate in such spaces. The system of heating premises described in the article is not a standard solution, but is now more and more commonly used as a supplement to the heating system, or even as a primary heating system in small objects, e.g. single-family houses, seasonal homes, etc. The studies comprised the measurements and analysis of typical internal micro-climate parameters: temperature, relative humidity and CO2 concentration. The results obtained did not raise any major reservations. In order to fully assess the conditions of use, the evaluation of thermal comfort of the analyzed rooms was made. Therefore, additionally the temperature of radiation of the surrounding areas, and the insulation of the users’ clothing was determined. Based on the data obtained, the PPD and PMV indices were determined according to EN ISO 7730: 2005 Ergonomics of the thermal environment - Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria [1]. The obtained PMV values did not fit within the limits of thermal comfort, and the percentage of people dissatisfied reached almost 20%.

  4. Multifamily Heat Pump Water Heater Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoeschele, M.; Weitzel, E.

    2017-03-03

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. Themore » TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.« less

  5. Multifamily Heat Pump Water Heater Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoeschele, M.; Weitzel, E.

    2017-03-01

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. Themore » TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.« less

  6. Operating experiences with rotary air-to-air heat exchangers: hospitals, schools, nursing homes, swimming pools

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pearson, R.J.

    1976-01-01

    Systems utilizing rotary air-to-air heat exchangers are discussed. Basic considerations of use (fresh air requirements, system configurations, cost considerations), typical system layout/design considerations, and operating observations by engineers, staff and maintenance personnel are described.

  7. Beaming-In On Student-Made Solar Technology

    ERIC Educational Resources Information Center

    Chiotelis, Charles L.

    1978-01-01

    Completion of a unit on heat energy motivated students to devise their own solar collectors, parabolic solar cookers, and designs for a solar home. Using their solar projects, the students tests hypotheses they might have had concerning heating capacities, insulation values, or energy conversions. (MA)

  8. Gusts of power

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-01-01

    This report reviews research on agricultural applications of wind energy. Shows irrigation projects in Bushland, TX, and Garden City, KS; cooling of milking parlor in Fort Collins, CO; heating a home in Bloomfield, IA; cooling stored apples in Blacksburg, VA; and an experimental water heating project in Ithaca, NY.

  9. Gusts of power

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1994-12-31

    This report reviews research on agricultural applications of wind energy. Shows irrigation projects in Bushland, TX, and Garden City, KS; cooling of milking parlor in Fort Collins, CO; heating a home in Bloomfield, IA; cooling stored apples in Blacksburg, VA; and an experimental water heating project in Ithaca, NY.

  10. Field testing of two prototype air-source integrated heat pumps for net zero energy home (nZEH) application

    DOE PAGES

    Baxter, Van D.; Munk, Jeffrey D.

    2017-11-08

    By integrating multiple functions into a single system it offers potential efficiency and cost reduction benefits. Oak Ridge National Laboratory (ORNL) and its partners have designed, developed, and tested two air-source heat pump designs that not only provide space heating and cooling, but also water heating, dehumidification, and ventilation functions. Some details on the design, simulated performance, prototype field test, measured performance, and lessons learned are provided.

  11. Field testing of two prototype air-source integrated heat pumps for net zero energy home (nZEH) application

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baxter, Van D.; Munk, Jeffrey D.

    By integrating multiple functions into a single system it offers potential efficiency and cost reduction benefits. Oak Ridge National Laboratory (ORNL) and its partners have designed, developed, and tested two air-source heat pump designs that not only provide space heating and cooling, but also water heating, dehumidification, and ventilation functions. Some details on the design, simulated performance, prototype field test, measured performance, and lessons learned are provided.

  12. Assessment of the US Department of Energy's Sustainable Energy Resources for Consumers Grant Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lenahan, Tim; Bausch, Daniel; Carroll, David

    This report presents the results of an assessment of the Sustainable Energy Resources for Consumers (SERC) grant program that was administered by the US Department of Energy Weatherization and Intergovernmental Program Office. Grants totaling $90 million were awarded to 101 local weatherization agencies located in 27 states. More than 15,000 housing units were touched by the SERC program. Close to 29,000 SERC technologies were installed and/or services delivered. The report summarizes the results of site visits to 27 agencies in which the following 14 technologies were observed: solar photovoltaic panels, solar hot water heaters, solar thermal air panels for spacemore » heating, tankless water heaters, heat pump water heaters, geothermal heat pumps, super-evaporative cooling systems, combination boilers and indirect water heaters, small-scale residential wind systems, cool roofs, masonry spray foam insulation, attic radiant barriers, mini-split heat pumps, and in-home energy monitors. The evaluation found that the national weatherization network is capable of installing and delivering a wide range of new and innovative technologies, but the usability and adoptability of some technologies may prove impractical for the weatherization network and the demographic for which it serves.« less

  13. Embedding technology into inter-professional best practices in home safety evaluation.

    PubMed

    Burns, Suzanne Perea; Pickens, Noralyn Davel

    2017-08-01

    To explore inter-professional home evaluators' perspectives and needs for building useful and acceptable decision-support tools for the field of home modifications. Twenty semi-structured interviews were conducted with a range of home modification professionals from different regions of the United States. The interview transcripts were analyzed with a qualitative, descriptive, perspective approach. Technology supports current best practice and has potential to inform decision making through features that could enhance home evaluation processes, quality, efficiency and inter-professional communication. Technological advances with app design have created numerous opportunities for the field of home modifications. Integrating technology and inter-professional best practices will improve home safety evaluation and intervention development to meet client-centred and societal needs. Implications for rehabilitation Understanding home evaluators technology needs for home safety evaluations contributes to the development of app-based assessments. Integrating inter-professional perspectives of best practice and technological needs in an app for home assessments improves processes. Novice and expert home evaluators would benefit from decision support systems embedded in app-based assessments. Adoption of app-based assessment would improve efficiency while remaining client-centred.

  14. A Home Ignition Assessment Model Applied to Structures in the Wildland-Urban Interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biswas, Kaushik; Werth, David; Gupta, Narendra

    2013-01-01

    The issue of exterior fire threat to buildings, from either wildfires in the wildland-urban interface or neighboring structure fires, is critically important. To address this, theWildfire Ignition Resistant Home Design (WIRHD) program was initiated. The WIRHD program developed a tool, theWildFIREWizard, that will allow homeowners to estimate the external fire threat to their homes based on specific features and characteristics of the homes and yards. The software then makes recommendations to reduce the threat. The inputs include the structural and material features of the home and information about any ignition sources or flammable objects in its immediate vicinity, known asmore » the home ignition zone. The tool comprises an ignition assessment model that performs explicit calculations of the radiant and convective heating of the building envelope from the potential ignition sources. This article describes a series of material ignition and flammability tests that were performed to calibrate and/or validate the ignition assessment model. The tests involved exposing test walls with different external siding types to radiant heating and/or direct flame contact.The responses of the test walls were used to determine the conditions leading to melting, ignition, or any other mode of failure of the walls. Temperature data were used to verify the model predictions of temperature rises and ignition times of the test walls.« less

  15. Impact of home remediation and household education on indoor air quality, respiratory visits and symptoms in Alaska Native children

    PubMed Central

    Singleton, Rosalyn; Salkoski, Aaron J.; Bulkow, Lisa; Fish, Chris; Dobson, Jennifer; Albertson, Leif; Skarada, Jennifer; Ritter, Troy; Kovesi, Thomas; Hennessy, Thomas W

    2018-01-01

    ABSTRACT Alaska Native children experience high rates of lower respiratory tract infections (LRTIs) and lung conditions, which are associated with substandard indoor air quality (IAQ). We conducted an intervention of home remediation and education to assess the impact on IAQ, respiratory symptoms and LRTI visits. We enrolled households of children 1–12 years of age with lung conditions. Home remediation included improving ventilation and replacing leaky woodstoves. We provided education about IAQ and respiratory health. We monitored indoor airborne particles (PM2.5), CO2, relative humidity and volatile organic compounds (VOCs), and interviewed caregivers about children’s symptoms before, and for 1 year after intervention. We evaluated the association between children’s respiratory visits, symptoms and IAQ indicators using multiple logistic regression. A total of 60 of 63 homes completed the study. VOCs decreased (coefficient = −0.20; p < 0.001); however, PM2.5 (coeff. = −0.010; p = 0.89) did not decrease. Burning wood for heat, VOCs and PM2.5 were associated with respiratory symptoms. After remediation, parents reported decreases in runny nose, cough between colds, wet cough, wheezing with colds, wheezing between colds and school absences. Children had an age-adjusted decrease in LRTI visits (coefficient = −0.33; p = 0.028). Home remediation and education reduced respiratory symptoms, LRTI visits and school absenteeism in children with lung conditions. PMID:29393004

  16. Impact of home remediation and household education on indoor air quality, respiratory visits and symptoms in Alaska Native children.

    PubMed

    Singleton, Rosalyn; Salkoski, Aaron J; Bulkow, Lisa; Fish, Chris; Dobson, Jennifer; Albertson, Leif; Skarada, Jennifer; Ritter, Troy; Kovesi, Thomas; Hennessy, Thomas W

    2018-12-01

    Alaska Native children experience high rates of lower respiratory tract infections (LRTIs) and lung conditions, which are associated with substandard indoor air quality (IAQ). We conducted an intervention of home remediation and education to assess the impact on IAQ, respiratory symptoms and LRTI visits. We enrolled households of children 1-12 years of age with lung conditions. Home remediation included improving ventilation and replacing leaky woodstoves. We provided education about IAQ and respiratory health. We monitored indoor airborne particles (PM2.5), CO 2 , relative humidity and volatile organic compounds (VOCs), and interviewed caregivers about children's symptoms before, and for 1 year after intervention. We evaluated the association between children's respiratory visits, symptoms and IAQ indicators using multiple logistic regression. A total of 60 of 63 homes completed the study. VOCs decreased (coefficient = -0.20; p < 0.001); however, PM2.5 (coeff. = -0.010; p = 0.89) did not decrease. Burning wood for heat, VOCs and PM2.5 were associated with respiratory symptoms. After remediation, parents reported decreases in runny nose, cough between colds, wet cough, wheezing with colds, wheezing between colds and school absences. Children had an age-adjusted decrease in LRTI visits (coefficient = -0.33; p = 0.028). Home remediation and education reduced respiratory symptoms, LRTI visits and school absenteeism in children with lung conditions.

  17. Energy Conservation in the Home. Performance Based Lesson Plans.

    ERIC Educational Resources Information Center

    Alabama State Dept. of Education, Montgomery. Home Economics Service.

    These ten performance-based lesson plans concentrate on tasks related to energy conservation in the home. They are (1) caulk cracks, holes, and joints; (2) apply weatherstripping to doors and windows; (3) add plastic/solar screen window covering; (4) arrange furniture for saving energy; (5) set heating/cooling thermostat; (6) replace faucet…

  18. 20 CFR 416.1157 - Support and maintenance assistance.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... spouse) of an alien, or essential person. Private nonprofit agency means a religious, charitable... spouse) if you are an alien, or an essential person. We also do not consider certain support and... kind by— (i) A supplier of home heating oil or gas; (ii) A rate-of-return entity providing home energy...

  19. 20 CFR 416.1157 - Support and maintenance assistance.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... spouse) of an alien, or essential person. Private nonprofit agency means a religious, charitable... spouse) if you are an alien, or an essential person. We also do not consider certain support and... kind by— (i) A supplier of home heating oil or gas; (ii) A rate-of-return entity providing home energy...

  20. 20 CFR 416.1157 - Support and maintenance assistance.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... spouse) of an alien, or essential person. Private nonprofit agency means a religious, charitable... spouse) if you are an alien, or an essential person. We also do not consider certain support and... kind by— (i) A supplier of home heating oil or gas; (ii) A rate-of-return entity providing home energy...

  1. The Hydrogen Challenge

    ERIC Educational Resources Information Center

    Roman, Harry T.

    2012-01-01

    Handling dangerous substances has come to define a society. People drive around with the explosive equivalent of twenty sticks of dynamite in their gasoline tanks without batting an eye. They use open flames to cook their food and heat their homes. Propane barbecue tanks are sold everywhere in the country, and left outside their homes for several…

  2. Women's Energy Tool Kit: Home Heating, Cooling and Weatherization.

    ERIC Educational Resources Information Center

    Byalin, Joan

    This book is the first in a series of Energy Tool Kits designed for women by Consumer Action Now, a non-profit organization devoted to promoting energy efficiency and renewable energy resources. Information is provided in 16 sections: introduction, home energy survey; caulking; weatherstripping (double-hung and sliding windows, and casement,…

  3. The Energy-Wise Homebuyer: A Guide to Selecting an Energy-Efficient Home.

    ERIC Educational Resources Information Center

    Hogarth, Peter T.; And Others

    Presented is a guide for purchasers of new or used homes who wish to make informed comparisons of energy costs. Included are 12 energy features to look for, detailed energy checklists, and charts for calculating energy expenses. Among the considerations discussed are heating systems, insulation, thermostats, caulking and weatherstripping, and…

  4. 20 CFR 416.1157 - Support and maintenance assistance.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... spouse) of an alien, or essential person. Private nonprofit agency means a religious, charitable... spouse) if you are an alien, or an essential person. We also do not consider certain support and... kind by— (i) A supplier of home heating oil or gas; (ii) A rate-of-return entity providing home energy...

  5. Residents' Coping Strategies in an Extended-Stay Hotel Home

    ERIC Educational Resources Information Center

    Lewinson, Terri

    2010-01-01

    Some families live in extended-stay hotels as a solution after housing displacement. This temporary accommodation provides a furnished home environment with resources such as a kitchenette, bed, heating/air conditioning, and room services with one payment that can be made weekly or monthly without a credit check or rent deposit. Despite these…

  6. Science at Home: Measuring a Thermophysical Property of Water with a Microwave Oven

    PubMed Central

    Levine, Zachary H.

    2018-01-01

    A measurement of a thermophysical property of water is made using items found in the author’s home. Specifically, the ratio of the energy required to heat water from the melting point to boiling to the energy required to completely boil away the water is found to be 5.7. This may be compared to the standard value of 5.5. The close agreement is not representative of the actual uncertainties in this simple experiment. Heating water in a microwave oven can let a student apply the techniques of quantitative science based on questions generated by his or her scientific curiosity. PMID:29542737

  7. Appliance energy efficiency in new home construction

    NASA Astrophysics Data System (ADS)

    1980-11-01

    A survey of 224 builders was conducted to which 160 builders responded. Each respondent completed between one and seven separate questionnaires. Each of the seven questionnaires were designed to collect information about one type of equipment or major appliance. These are: heat pump; heating system; air conditioner; domestic water heater; dishwasher; range; and refrigerator. Analyses of the resulting 406 questionnaires indicated that builders were primarily responsible for brand selection. These choices were made primarily without regard for the secondary efficiency of the product. A similar apparent lack of consideration of energy efficiency during brand and model selection was found among home buyers and specialized subcontractors.

  8. Estimating U.S. residential demand for fuelwood in the presence of selectivity

    NASA Astrophysics Data System (ADS)

    Daly, Ryan Michael

    Residential energy consumers have options for home heating. With many applications, appliances, and fuel types, fuelwood used for heating faces stiff competition in modern society from other fuels. This study estimates demand for domestic fuelwood. It also examines whether evidence of bias exists from residential homes choosing to use fuelwood. The use of OLS as an estimator will yield biased results if such selectivity exists. Selectivity is addressed with a Heckman (1979) two-step procedure; bias in fuelwood demand estimation using OLS is reduced. Non-wood energy prices and income are major determinants of fuelwood demand. Geographical regions and urbanization confirm results from prior studies.

  9. Best Practices Case Study: David Weekley Homes - Eagle Springs and Waterhaven, Houston, TX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2011-04-01

    Case study describing David Weekley Homes, Houston Division, has qualified more than 1,240 homes for the DOE Builders Challenge. Advanced framed 2x6 walls with open headers and two-stud corners allow more room for R-20 damp sprayed cellulose wall cavity insulation that is covered with R-5 rigid XPS foam. A radiant barrier cuts heat gain in the R-38 insulated vented attics. Draft stopping at fireplace and duct chases and behind tubs, gluing sheetrock to framing, and extensive caulking make for air-tight homes at 3.0 ACH50.

  10. DOE Zero Energy Ready Home Case Study: Healthy Efficient Homes - Spirit Lake, Iowa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2014-11-01

    This case study describes a DOE Zero Energy Ready Home in Spirit Lake, Iowa, that scored HERS 41 without PV and HERS 28 with PV. This 3,048 ft2 custom home has advanced framed walls filled with 1.5 inches closed-cell spray foam, a vented attic with spray foam-sealed top plates and blown fiberglass over the ceiling deck. R-23 basement walls are ICF plus two 2-inch layers of EPS. The house also has a mini-split heat pump, fresh air fan intake, and a solar hot water heater.

  11. Reducing indoor air pollutants with air filtration units in wood stove homes.

    PubMed

    McNamara, Marcy L; Thornburg, Jonathon; Semmens, Erin O; Ward, Tony J; Noonan, Curtis W

    2017-08-15

    Biomass burning has been shown to be a major source of poor indoor air quality (IAQ) in developing and higher income countries across the world. Specifically, wood burning for cooking and heating contributes to high indoor concentrations of fine (particles with aerodynamic diameters<2.5μm; PM 2.5 ) and coarse (particles with aerodynamic diameters <10μm and >2.5μm; PMc) particulate matter. Endotoxin, predominantly found within the coarse fraction of airborne particulate matter, is associated with proinflammatory effects and adverse outcomes among susceptible populations. The aim of this study was to assess the efficacy of air filter interventions in reducing indoor PM 2.5 , PMc, and PMc-associated endotoxin concentrations in homes using a wood stove for primary heating. Homes (n=48) were randomized to receive in-room air filtration units with either a high efficiency filter (i.e. active) or a lower efficiency fiberglass filter (i.e., placebo). The active filter intervention showed a 66% reduction in indoor PM 2.5 concentrations (95% CI: 42.2% to 79.7% reduction) relative to the placebo intervention. Both the active and the placebo filters were effective in substantially reducing indoor concentrations of PMc (63.3% and 40.6% average reduction for active and placebo filters, respectively) and PMc-associated endotoxin concentrations (91.8% and 80.4% average reductions, respectively). These findings support the use of high efficiency air filtration units for reducing indoor PM 2.5 in homes using a wood stove for primary heating. We also discovered that using lower efficiency, lower cost filter alternatives can be effective for reducing PMc and airborne endotoxin in homes burning biomass fuel. Copyright © 2017. Published by Elsevier B.V.

  12. Coping with heat in the city: what can we learn from a survey immediately after a hot weather period for future heat waves?

    NASA Astrophysics Data System (ADS)

    Kunz-Plapp, Tina; Schipper, Hans; Hackenbruch, Julia

    2015-04-01

    Karlsruhe is one of the hottest cities in Germany with a temperature record of 40.2°C in August 2003. In 2013, two hot weather periods with continuous heat warnings by the German Weather Service for 7 and 8 days occurred during the second half of July and first 10 days of August 2013, and in early August the temperatures in Karlsruhe almost reached again the record of 40.2°C. To understand how citizens experienced the heat and what strategies they used to cope with the heat, we conducted a questionnaire survey on subjective heat stress and coping strategies immediately after the hot weather period. Based on a holistic approach the questionnaire included questions on heat stress experience in different contexts of daily life, health impacts of the heat, coping measures, housing conditions, urban environment, living conditions, and socio-demographic characteristics. The responses of the 323 survey participants living and working in Karlsruhe show that they on average experienced the heat as rather stressful event, whereby the heat stress experienced at home was significant lower than heat stress experienced at work or in general. Regression analyses show that, among the factors included in the questionnaire, the health impairments suffered during the heat, the control belief and the coping measures implemented mainly determine heat stress experienced in general and at work. For the subjective heat stress at home, factors of the built urban environment such as heat loading of district, living in the attic or the ground floor, and heat protection elements of the inhabited building also played a role. At the same time, the way the respondents used different coping strategies in context of their daily activities and routines during heat suggests lessons to learn from this event how individual response to heat differs from responses to other types of natural hazards.

  13. Effect of Ducted HPWH on Space-Conditioning and Water Heating Energy Use -- Central Florida Lab Home

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colon, Carlos; Martin, Eric; Parker, Danny

    2016-11-01

    The purpose of this research is to investigate the impact of ducted heat pump water heaters (HPWHs) on space conditioning and water heating energy use in residential applications. Two identical HPWHs, each of 60 gallon capacity were tested side by side at the Flexible Residential Test facility (FRTF) laboratories of the Florida Solar Energy Center (FSEC) campus in Cocoa, Florida. The water heating experiments were run in each test house from July 2014 until February 2015.

  14. Effect of Ducted HPWH on Space-Conditioning and Water Heating Energy Use -- Central Florida Lab Home

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colon, Carlos; Martin, Eric; Parker, Danny

    2016-11-01

    The purpose of this research is to investigate the impact of ducted heat pump water heaters (HPWH's) on space conditioning and water heating energy use in residential applications. Two identical HPWH's, each of 60 gallon capacity were tested side by side at the Flexible Residential Test facility (FRTF) laboratories of the Florida Solar Energy Center (FSEC) campus in Cocoa, Florida. The water heating experiments were run in each test house from July 2014 until February 2015.

  15. Gas-fired duplex free-piston Stirling refrigerator

    NASA Astrophysics Data System (ADS)

    Urieli, L.

    1984-03-01

    The duplex free-piston Stirling refrigerator is a potentially high efficiency, high reliability device which is ideally suited to the home appliance field, in particular as a gas-fired refrigerator. It has significant advantages over other equivalent devices including freedom from halogenated hydrocarbons, extremely low temperatures available at a high efficiency, integrated water heating, and simple burner system control. The design and development of a portable working demonstration gas-fired duplex Stirling refrigeration unit is described. A unique combination of computer aided development and experimental development was used, enabling a continued interaction between the theoretical analysis and practical testing and evaluation. A universal test rig was developed in order to separately test and evaluate major subunits, enabling a smooth system integration phase.

  16. Residential solar-heating system-design package

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Design package for modular solar heating system includes performance specifications, design data, installation guidelines, and other information that should be valuable to those interested in system (or similar systems) for projected installation. When installed in insulated "energy saver" home, system can supply large percentage of total energy needs of building.

  17. 77 FR 12590 - Winchester Industries; Analysis of Proposed Consent Order To Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-01

    ... homeowners can realize by replacing their windows, including the home's geographic location, size, insulation... insulation in a specific region). The performance standard imposed under this Part constitutes fencing-in... costs, heating and cooling costs, U-factor, solar heat gain coefficient, R-value, K-value, insulating...

  18. 77 FR 12586 - Serious Energy, Inc.; Analysis of Proposed Consent Order To Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-01

    ... the home's geographic location, size, insulation package, and existing windows. Consumers who replace... insulation in a specific region). The performance standard imposed under this Part constitutes fencing-in... costs, heating and cooling costs, U-factor, solar heat gain coefficient, R-value, K-value, insulating...

  19. Projects in a Solar Energy Course.

    ERIC Educational Resources Information Center

    Lindsay, Richard H.

    1983-01-01

    Describes student projects on applications of solar energy optics to home design. Project criterion (requiring sketches and detailed calculations of time rate of energy flow/production) is that half the heat for the heating season be taken from the solar resource; calculations must be based on meteorological data for a specific location. (JM)

  20. How to Save Money by Saving Energy.

    ERIC Educational Resources Information Center

    Department of Energy, Washington, DC.

    This pamphlet presents energy conservation tips to help consumers save money. Conservation measures suggested here cover topics such as: (1) insulation; (2) space heating and cooling; (3) hot water heating; (4) cooking; (5) laundry; (6) lighting; (7) electrical appliances; (8) buying or building a home; and (9) buying, maintaining and driving a…

  1. Demonstration PreFab Solar Heated Vacation Home

    ERIC Educational Resources Information Center

    Ariola, Frank; Walencik, Vincent J.

    1978-01-01

    To update a traditional construction shop program, students at Passaic Valley High School, New Jersey, developed a mock-up model of a solar-heated A-frame vacation house using prefab construction. The article describes the project and illustrates it with photographs of the model and a drawing of the solar collector. (MF)

  2. Keys to the House: Unlocking Residential Savings With Program Models for Home Energy Upgrades

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grevatt, Jim; Hoffman, Ian; Hoffmeyer, Dale

    After more than 40 years of effort, energy efficiency program administrators and associated contractors still find it challenging to penetrate the home retrofit market, especially at levels commensurate with state and federal goals for energy savings and emissions reductions. Residential retrofit programs further have not coalesced around a reliably successful model. They still vary in design, implementation and performance, and they remain among the more difficult and costly options for acquiring savings in the residential sector. If programs are to contribute fully to meeting resource and policy objectives, administrators need to understand what program elements are key to acquiring residentialmore » savings as cost effectively as possible. To that end, the U.S. Department of Energy (DOE) sponsored a comprehensive review and analysis of home energy upgrade programs with proven track records, focusing on those with robustly verified savings and constituting good examples for replication. The study team reviewed evaluations for the period 2010 to 2014 for 134 programs that are funded by customers of investor-owned utilities. All are programs that promote multi-measure retrofits or major system upgrades. We paid particular attention to useful design and implementation features, costs, and savings for nearly 30 programs with rigorous evaluations of performance. This meta-analysis describes program models and implementation strategies for (1) direct install retrofits; (2) heating, ventilating and air-conditioning (HVAC) replacement and early retirement; and (3) comprehensive, whole-home retrofits. We analyze costs and impacts of these program models, in terms of both energy savings and emissions avoided. These program models can be useful guides as states consider expanding their strategies for acquiring energy savings as a resource and for emissions reductions. We also discuss the challenges of using evaluations to create program models that can be confidently applied in multiple jurisdictions.« less

  3. Community Trial on Heat Related-Illness Prevention Behaviors and Knowledge for the Elderly

    PubMed Central

    Takahashi, Noriko; Nakao, Rieko; Ueda, Kayo; Ono, Masaji; Kondo, Masahide; Honda, Yasushi; Hashizume, Masahiro

    2015-01-01

    This study aims to explore whether broadcasting heat health warnings (HHWs), to every household and whether the additional home delivery of bottled water labeled with messages will be effective in improving the behaviors and knowledge of elderly people to prevent heat-related illness. A community trial on heat-related-illness-prevention behaviors and knowledge for people aged between 65 and 84 years was conducted in Nagasaki, Japan. Five hundred eight subjects were selected randomly from three groups: heat health warning (HHW), HHW and water delivery (HHW+W), and control groups. Baseline and follow-up questionnaires were conducted in June and September 2012, respectively. Of the 1524 selected subjects, the 1072 that completed both questionnaires were analyzed. The HHW+W group showed improvements in nighttime AC use (p = 0.047), water intake (p = 0.003), cooling body (p = 0.002) and reduced activities in heat (p = 0.047) compared with the control, while the HHW group improved hat or parasol use (p = 0.008). An additional effect of household water delivery was observed in water intake (p = 0.067) and cooling body (p = 0.095) behaviors. HHW and household bottled water delivery improved heat-related-illness-prevention behaviors. The results indicate that home water delivery in addition to a HHW may be needed to raise awareness of the elderly. PMID:25789456

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rice, C. Keith; Shen, Bo; Shrestha, Som S.

    This report describes an analysis to investigate representative heating loads for single-family detached homes using current EnergyPlus simulations (DOE 2014a). Hourly delivered load results are used to determine binned load lines using US Department of Energy (DOE) residential prototype building models (DOE 2014b) developed by Pacific Northwest National Laboratory (PNNL). The selected residential single-family prototype buildings are based on the 2006 International Energy Conservation Code (IECC 2006) in the DOE climate regions. The resulting load lines are compared with the American National Standards Institute (ANSI)/Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Standard 210/240 (AHRI 2008) minimum and maximum design heating requirementmore » (DHR) load lines of the heating seasonal performance factor (HSPF) ratings procedure for each region. The results indicate that a heating load line closer to the maximum DHR load line, and with a lower zero load ambient temperature, is more representative of heating loads predicted for EnergyPlus prototype residential buildings than the minimum DHR load line presently used to determine HSPF ratings. An alternative heating load line equation was developed and compared to binned load lines obtained from the EnergyPlus simulation results. The effect on HSPF of the alternative heating load line was evaluated for single-speed and two-capacity heat pumps, and an average HSPF reduction of 16% was found. The alternative heating load line relationship is tied to the rated cooling capacity of the heat pump based on EnergyPlus autosizing, which is more representative of the house load characteristics than the rated heating capacity. The alternative heating load line equation was found to be independent of climate for the six DOE climate regions investigated, provided an adjustable zero load ambient temperature is used. For Region IV, the default DOE climate region used for HSPF ratings, the higher load line results in an ~28% increase in delivered heating load and an ~52% increase in the estimated heating operating cost over that given in the AHRI directory (AHRI 2014).« less

  5. Place of origin and violent disagreement among Asian American families: analysis across five States.

    PubMed

    Wang, Jong-Yi; Probst, Janice C; Moore, Charity G; Martin, Amy B; Bennett, Kevin J

    2011-08-01

    We examined the prevalence of and factors associated with violent and heated disagreements in the Asian American families, with an emphasis on place of birth differences between parent and child. Data were obtained from the 2003 National Survey of Children's Health, limited to five states with the highest concentration of Asian-Americans (n = 793). Multivariable analysis used generalized logistic regression models with a three-level outcome, violent and heated disagreement versus calm discussion. Violent disagreements were reported in 13.7% of Asian-American homes and 9.9% of white homes. Differential parent-child place of birth was associated with increased odds for heated disagreement in Asian-American families. Parenting stress increased the likelihood of violent disagreements in both Asian-American and white families. Asian-American families are not immune to potential family violence. Reducing parenting stress and intervening in culturally appropriate ways to reduce generation differences should be violence prevention priorities.

  6. Can industry afford solar energy

    NASA Astrophysics Data System (ADS)

    Kreith, F.; Bezdek, R.

    1983-03-01

    Falling oil prices and conservation measures have reduced the economic impetus to develop new energy sources, thus decreasing the urgency for bringing solar conversion technologies to commercial readiness at an early date. However, the capability for solar to deliver thermal energy for industrial uses is proven. A year-round operation would be three times as effective as home heating, which is necessary only part of the year. Flat plate, parabolic trough, and solar tower power plant demonstration projects, though uneconomically operated, have revealed engineering factors necessary for successful use of solar-derived heat for industrial applications. Areas of concern have been categorized as technology comparisons, load temperatures, plant size, location, end-use, backup requirements, and storage costs. Tax incentives have, however, supported home heating and not industrial uses, and government subsidies have historically gone to conventional energy sources. Tax credit programs which could lead to a 20% market penetration by solar energy in the industrial sector by the year 2000 are presented.

  7. Energy Projects for Young Scientists.

    ERIC Educational Resources Information Center

    Gardner, Robert

    Energy is a vital topic. Energy costs have risen dramatically during the last decade and home owners are concerned about their energy bills and the costs associated with heating or cooling their homes. An understanding of energy, its sources and ways to reduce its use or improve the efficiency with which people use it will become more important as…

  8. Energy Conservation and Solar Retrofitting for Existing Buildings in Oregon: An Architectural Design Class Project.

    ERIC Educational Resources Information Center

    Oregon Univ., Eugene. School of Architecture and Allied Arts.

    Five privately owned homes and two university owned homes were examined by architecture students in order to formulate design alternatives to fit the houses with solar collection, storage, and control devices for supplementing domestic space and/or water heating. General principles advanced include why energy conservation and solar retrofitting…

  9. The Mother and Infant Home Visiting Program Evaluation: Early Findings on the Maternal, Infant, and Early Childhood Home Visiting Program. A Report to Congress. OPRE Report 2015-11

    ERIC Educational Resources Information Center

    Michalopoulos, Charles; Lee, Helen; Duggan, Anne; Lundquist, Erika; Tso, Ada; Crowne, Sarah Shea; Burrell, Lori; Somers, Jennifer; Filene, Jill H.; Knox, Virginia

    2015-01-01

    "The Mother and Infant Home Visiting Program Evaluation: Early Findings on the Maternal, Infant, and Early Childhood Home Visiting Program--A Report to Congress" presents the first findings from the Mother and Infant Home Visiting Program Evaluation (MIHOPE), the legislatively mandated national evaluation of the Maternal, Infant, and…

  10. Science at Home: Measuring a Thermophysical Property of Water with a Microwave Oven

    NASA Astrophysics Data System (ADS)

    Levine, Zachary H.

    2018-02-01

    An attempt to calibrate a conventional oven led to making a measurement of a thermophysical property of water using items found in the author's home. Specifically, the ratio of the energy required to heat water from the melting point to boiling to the energy required to completely boil away the water is found to be 5.7. This may be compared to the standard value of 5.5. The close agreement is not representative of the actual uncertainties in this simple experiment (Fig. 1). Heating water in a microwave oven can let a student apply the techniques of quantitative science based on questions generated by his or her scientific curiosity.

  11. Solar for Your Present Home. San Francisco Bay Area Edition.

    ERIC Educational Resources Information Center

    Barnaby, Charles S.; And Others

    This publication provides information about present uses of solar energy for space, water, and swimming pool heating that are practical for the San Francisco Bay area. It attempts to provide interested persons with the information needed to make decisions regarding installations of solar heating systems. The point of view taken is that any…

  12. The Cold Blooded Killer: Hypothermia.

    ERIC Educational Resources Information Center

    Keller, Rosanne

    Part of a series of home literacy readers with conversational text and sketches, this booklet depicts the subarctic Alaskan environment where cold makes extreme demands on body metabolism. Body temperature must be maintained above 80F (26.7C). A condition of too little body-heat is termed hypo- ('deficit') thermia ('heat'). Hypothermia is the…

  13. Tips for Energy Savers.

    ERIC Educational Resources Information Center

    Department of Energy, Washington, DC.

    According to 1986 U.S. Department of Energy data, 48% of our residential energy is used to heat and cool our homes, 16% goes for heating water, 12% is used to refrigerators and freezers, and the remaining 24% goes into lighting, cooking, and running appliances. This booklet contains tips for saving energy, including sections on: (1) draft-proof…

  14. 77 FR 12591 - THV Holdings LLC; Analysis of Proposed Consent Order To Aid Public Comment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-01

    ... homeowners can realize by replacing their windows, including the home's geographic location, size, insulation... having a specific level of insulation in a specific region). The performance standard imposed under this... consumption, energy savings, energy costs, heating and cooling costs, U-factor, solar heat gain coefficient, R...

  15. Heat Loss Experiments: Teach Energy Savings with Cardboard "House"

    ERIC Educational Resources Information Center

    Roman, Harry T.

    2011-01-01

    Using two cardboard boxes, a light bulb socket, light bulbs of varying wattage, a thermometer, and some insulation, students can learn some interesting lessons about how heat loss occurs in homes. This article describes practical experiments that work well on units related to energy, sustainable energy, renewables, engineering, and construction.…

  16. Physical and Chemical Properties of Bio-Oils From Microwave Pyrolysis of Corn Stover

    NASA Astrophysics Data System (ADS)

    Yu, Fei; Deng, Shaobo; Chen, Paul; Liu, Yuhuan; Wan, Yiqin; Olson, Andrew; Kittelson, David; Ruan, Roger

    This study was aimed to understand the physical and chemical properties of pyrolytic bio-oils produced from microwave pyrolysis of corn stover regarding their potential use as gas turbine and home heating fuels. The ash content, solids content, pH, heating value, minerals, elemental ratio, moisture content, and viscosity of the bio-oils were determined. The water content was approx 15.2 wt%, solids content 0.22 wt%, alkali metal content 12 parts per million, dynamic viscosity 185 mPa·s at 40°C, and gross high heating value 17.5 MJ/kg for a typical bio-oil produced. Our aging tests showed that the viscosity and water content increased and phase separation occurred during the storage at different temperatures. Adding methanol and/or ethanol to the bio-oils reduced the viscosity and slowed down the increase in viscosity and water content during the storage. Blending of methanol or ethanol with the bio-oils may be a simple and cost-effective approach to making the pyrolytic bio-oils into a stable gas turbine or home heating fuels.

  17. Physical and chemical properties of bio-oils from microwave pyrolysis of corn stover.

    PubMed

    Yu, Fei; Deng, Shaobo; Chen, Paul; Liu, Yuhuan; Wan, Yiqin; Olson, Andrew; Kittelson, David; Ruan, Roger

    2007-04-01

    This study was aimed to understand the physical and chemical properties of pyrolytic bio-oils produced from microwave pyrolysis of corn stover regarding their potential use as gas turbine and home heating fuels. The ash content, solids content, pH, heating value, minerals, elemental ratio, moisture content, and viscosity of the bio-oils were determined. The water content was approx 15.2 wt%, solids content 0.22 wt%, alkali metal content 12 parts per million, dynamic viscosity 185 mPa.s at 40 degrees C, and gross high heating value 17.5 MJ/kg for a typical bio-oil produced. Our aging tests showed that the viscosity and water content increased and phase separation occurred during the storage at different temperatures. Adding methanol and/or ethanol to the bio-oils reduced the viscosity and slowed down the increase in viscosity and water content during the storage. Blending of methanol or ethanol with the bio-oils may be a simple and cost-effective approach to making the pyrolytic bio-oils into a stable gas turbine or home heating fuels.

  18. Wood Stove Pollution in the Developed World: A Case to Raise Awareness Among Pediatricians.

    PubMed

    Rokoff, Lisa B; Koutrakis, Petros; Garshick, Eric; Karagas, Margaret R; Oken, Emily; Gold, Diane R; Fleisch, Abby F

    2017-06-01

    Use of wood for residential heating is regaining popularity in developed countries. Currently, over 11 million US homes are heated with a wood stove. Although wood stoves reduce heating costs, wood smoke may adversely impact child health through the emission of gaseous and particulate air pollutants. Our purpose is to raise awareness of this environmental health issue among pediatricians. To summarize the state of the science, we performed a narrative review of articles published in PubMed and Web of Science. We identified 36 studies in developed countries that reported associations of household wood stove use and/or community wood smoke exposure with pediatric health outcomes. Studies primarily investigated respiratory outcomes, with no evaluation of cardiometabolic or neurocognitive health. Studies found community wood smoke exposure to be consistently associated with adverse pediatric respiratory health. Household wood stove use was less consistently associated with respiratory outcomes. However, studies of household wood stoves always relied on participant self-report of wood stove use, while studies of community wood smoke generally assessed air pollution exposure directly and more precisely in larger study populations. In most studies, important potential confounders, such as markers of socioeconomic status, were unaccounted for and may have biased results. We conclude that studies with improved exposure assessment, that measure and account for confounding, and that consider non-respiratory outcomes are needed. While awaiting additional data, pediatricians can refer patients to precautionary measures recommended by the US Environmental Protection Agency (EPA) to mitigate exposure. These include replacing old appliances with EPA-certified stoves, properly maintaining the stove, and using only dry, well-seasoned wood. In addition, several studies have shown mechanical air filters to effectively reduce wood stove pollution exposure in affected homes and communities. Copyright © 2017 Mosby, Inc. All rights reserved.

  19. Wood Stove Pollution in the Developed World: A Case to Raise Awareness Among Pediatricians

    PubMed Central

    Rokoff, Lisa B.; Koutrakis, Petros; Garshick, Eric; Karagas, Margaret R.; Oken, Emily; Gold, Diane R.; Fleisch, Abby F.

    2017-01-01

    Use of wood for residential heating is regaining popularity in developed countries. Currently, over 11 million US homes are heated with a wood stove. Although wood stoves reduce heating costs, wood smoke may adversely impact child health through the emission of gaseous and particulate air pollutants. Our purpose is to raise awareness of this environmental health issue among pediatricians. To summarize the state of the science, we performed a narrative review of articles published in PubMed and Web of Science. We identified 36 studies in developed countries that reported associations of household wood stove use and/or community wood smoke exposure with pediatric health outcomes. Studies primarily investigated respiratory outcomes, with no evaluation of cardiometabolic or neurocognitive health. Studies found community wood smoke exposure to be consistently associated with adverse pediatric respiratory health. Household wood stove use was less consistently associated with respiratory outcomes. However, studies of household wood stoves always relied on participant self-report of wood stove use, while studies of community wood smoke generally assessed air pollution exposure directly and more precisely in larger study populations. In most studies, important potential confounders, such as markers of socioeconomic status, were unaccounted for and may have biased results. We conclude that studies with improved exposure assessment, that measure and account for confounding, and that consider non-respiratory outcomes are needed. While awaiting additional data, pediatricians can refer patients to precautionary measures recommended by the US Environmental Protection Agency (EPA) to mitigate exposure. These include replacing old appliances with EPA-certified stoves, properly maintaining the stove, and using only dry, well-seasoned wood. In addition, several studies have shown mechanical air filters to effectively reduce wood stove pollution exposure in affected homes and communities. PMID:28583817

  20. Aryl hydrocarbon receptor expression is associated with a family history of upper gastrointestinal tract cancer in a high-risk population exposed to aromatic hydrocarbons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roth, M.J.; Wei, W.Q.; Baer, J.

    2009-09-15

    Polycyclic aromatic hydrocarbon (PAH) exposure is a risk factor for esophageal squamous cell carcinoma, and PAHs are ligands of the aryl hydrocarbon receptor (AhR). This study measured the expression of AhR and related genes in frozen esophageal cell samples from patients exposed to different levels of indoor air pollution, who did or did not have high-grade squamous dysplasia and who did or did not have a family history of upper gastrointestinal tract (UGI) cancer. 147 samples were evaluated, including 23 (16%) from patients with high-grade dysplasia and 48 (33%) from patients without dysplasia who heated their homes with coal, withoutmore » a chimney (a 'high' indoor air pollution group), and 27 (18%) from patients with high-grade dysplasia and 49 (33%) from patients without dysplasia who did not heat their homes at all (a 'low' indoor air pollution group). Sixty-four (44%) had a family history of UGI cancer. RNA was extracted and quantitative PCR analysis was done. AhR gene expression was detectable in 85 (58%) of the samples and was >9-fold higher in those with a family history of UGI cancer (median expression (interquartile range), -1,964 (-18,000, -610) versus -18,000 (-18,000, -1036); P = 0.02, Wilcoxon rank-sum test). Heating status, dysplasia category, age, gender, and smoking were not associated with AhR expression (linear regression; all P values {ge} 0.1). AhR expression was higher in patients with a family history of UGI cancer. Such individuals may be more susceptible to the deleterious effects of PAH exposure, including PAH-induced cancer.« less

  1. Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes - Business Case Assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baxter, Van D

    2007-05-01

    The long range strategic goal of the Department of Energy's Building Technologies (DOE/BT) Program is to create, by 2020, technologies and design approaches that enable the construction of net-zero energy homes at low incremental cost (DOE/BT 2005). A net zero energy home (NZEH) is a residential building with greatly reduced needs for energy through efficiency gains, with the balance of energy needs supplied by renewable technologies. While initially focused on new construction, these technologies and design approaches are intended to have application to buildings constructed before 2020 as well resulting in substantial reduction in energy use for all building typesmore » and ages. DOE/BT's Emerging Technologies (ET) team is working to support this strategic goal by identifying and developing advanced heating, ventilating, air-conditioning, and water heating (HVAC/WH) technology options applicable to NZEHs. Although the energy efficiency of heating, ventilating, and air-conditioning (HVAC) equipment has increased substantially in recent years, new approaches are needed to continue this trend. Dramatic efficiency improvements are necessary to enable progress toward the NZEH goals, and will require a radical rethinking of opportunities to improve system performance. The large reductions in HVAC energy consumption necessary to support the NZEH goals require a systems-oriented analysis approach that characterizes each element of energy consumption, identifies alternatives, and determines the most cost-effective combination of options. In particular, HVAC equipment must be developed that addresses the range of special needs of NZEH applications in the areas of reduced HVAC and water heating energy use, humidity control, ventilation, uniform comfort, and ease of zoning. In FY05 ORNL conducted an initial Stage 1 (Applied Research) scoping assessment of HVAC/WH systems options for future NZEHs to help DOE/BT identify and prioritize alternative approaches for further development. Eleven system concepts with central air distribution ducting and nine multi-zone systems were selected and their annual and peak demand performance estimated for five locations: Atlanta (mixed-humid), Houston (hot-humid), Phoenix (hot-dry), San Francisco (marine), and Chicago (cold). Performance was estimated by simulating the systems using the TRNSYS simulation engine (Solar Energy Laboratory et al. 2006) in two 1800-ft{sup 2} houses--a Building America (BA) benchmark house and a prototype NZEH taken from BEopt results at the take-off (or crossover) point (i.e., a house incorporating those design features such that further progress towards ZEH is through the addition of photovoltaic power sources, as determined by current BEopt analyses conducted by NREL). Results were summarized in a project report, 'HVAC Equipment Design options for Near-Zero-Energy Homes--A Stage 2 Scoping Assessment', ORNL/TM-2005/194 (Baxter 2005). The 2005 study report describes the HVAC options considered, the ranking criteria used, and the system rankings by priority. Table 1 summarizes the energy savings potential of the highest scoring options from the 2005 study for all five locations. All system options were scored by the ORNL building equipment research team and by William Goetzler of Navigant Consulting. These scores were reviewed by DOE/BT's Residential Integration program leaders and Building America team members. Based on these results, the two centrally ducted integrated heat pump (IHP) systems (air source and ground source versions) were selected for advancement to Stage 2 (Exploratory Development) business case assessments in FY06. This report describes results of these business case assessments. It is a compilation of three separate reports describing the initial business case study (Baxter 2006a), an update to evaluate the impact of an economizer cooling option (Baxter 2006b), and a second update to evaluate the impact of a winter humidification option (Baxter 2007). In addition it reports some corrections made subsequent to release of the first two reports to correct some errors in the TRNSYS building model for Atlanta and in the refrigerant pressure drop calculation in the water-to-refrigerant evaporator module of the ORNL Heat Pump Design Model (HPDM) used for the IHP analyses. These changes resulted in some minor differences between IHP performance as reported in Baxter (2006a, b) and in this report.« less

  2. Building America Case Study: Effect of Ducted HPWH on Space Conditioning and Water Heating Energy Use - Central Florida Lab Home, Cocoa, Florida

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2017-04-01

    The purpose of this research is to investigate the impact of ducted heat pump water heaters (HPWH's) on space conditioning and water heating energy use in residential applications. Two identical HPWH's, each of 60 gallon capacity were tested side by side at the Flexible Residential Test facility (FRTF) laboratories of the Florida Solar Energy Center (FSEC) campus in Cocoa, Florida. The water heating experiments were run in each test house from July 2014 until February 2015.

  3. Energy Use Consequences of Ventilating a Net-Zero Energy House

    PubMed Central

    Ng, Lisa C.; Payne, W. Vance

    2016-01-01

    A Net-Zero Energy Residential Test Facility (NZERTF) has been constructed at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland to demonstrate that a home similar in size, aesthetics, and amenities to those in the surrounding communities can achieve net-zero energy use over the course of a year while meeting the average electricity and water use needs of a family of four in the United States. The facility incorporates renewable energy and energy efficient technologies, including an air-to-air heat pump system, a solar photovoltaic system, a solar thermal domestic hot water system, and a heat recovery ventilation system sized to meet American Society of Heating, Refrigeration, and Air-Conditioning Engineers (ASHRAE) Standard 62.2-2010 ventilation requirements. The largest energy end use within the home was space conditioning, which included heat loss through the building envelope, ventilation air supplied by the heat recovery ventilator (HRV), and internal loads. While HRVs are often described as being able to save energy when compared to ventilating without heat recovery, there have been no studies using a full year of measured data that determine the thermal load and energy impacts of HRV-based ventilation on the central heating and cooling system. Over the course of a year, continuous operation of the HRV at the NZERTF resulted in an annual savings of 7 % in heat pump energy use compared with the hypothetical case of ventilating without heat recovery. The heat pump electrical use varied from an increase of 5 % in the cooling months to 36 % savings in the heating months compared with ventilation without heat recovery. The increase in the cooling months occurred when the outdoor temperature was lower than the indoor temperature, during which the availability of an economizer mode would have been beneficial. Nevertheless, the fan energy required to operate the selected HRV at the NZERTF paid for itself in the heat pump energy saved compared with ventilation without heat recovery. PMID:26903776

  4. Energy Use Consequences of Ventilating a Net-Zero Energy House.

    PubMed

    Ng, Lisa C; Payne, W Vance

    2016-03-05

    A Net-Zero Energy Residential Test Facility (NZERTF) has been constructed at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland to demonstrate that a home similar in size, aesthetics, and amenities to those in the surrounding communities can achieve net-zero energy use over the course of a year while meeting the average electricity and water use needs of a family of four in the United States. The facility incorporates renewable energy and energy efficient technologies, including an air-to-air heat pump system, a solar photovoltaic system, a solar thermal domestic hot water system, and a heat recovery ventilation system sized to meet American Society of Heating, Refrigeration, and Air-Conditioning Engineers (ASHRAE) Standard 62.2-2010 ventilation requirements. The largest energy end use within the home was space conditioning, which included heat loss through the building envelope, ventilation air supplied by the heat recovery ventilator (HRV), and internal loads. While HRVs are often described as being able to save energy when compared to ventilating without heat recovery, there have been no studies using a full year of measured data that determine the thermal load and energy impacts of HRV-based ventilation on the central heating and cooling system. Over the course of a year, continuous operation of the HRV at the NZERTF resulted in an annual savings of 7 % in heat pump energy use compared with the hypothetical case of ventilating without heat recovery. The heat pump electrical use varied from an increase of 5 % in the cooling months to 36 % savings in the heating months compared with ventilation without heat recovery. The increase in the cooling months occurred when the outdoor temperature was lower than the indoor temperature, during which the availability of an economizer mode would have been beneficial. Nevertheless, the fan energy required to operate the selected HRV at the NZERTF paid for itself in the heat pump energy saved compared with ventilation without heat recovery.

  5. Winter Survival: A Consumer's Guide to Winter Preparedness.

    ERIC Educational Resources Information Center

    Department of Energy, Washington, DC.

    This booklet discusses a variety of topics to help consumers prepare for winter. Tips for the home include: winterizing the home, dealing with a loss of heat or power failure, and what you need to have on hand. Another section gives driving tips and what to do in a storm. Health factors include suggestions for keeping warm, signs and treatment for…

  6. Performance Verification of Production-Scalable Energy-Efficient Solutions: Winchester/Camberley Homes Mixed-Humid Climate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mallay, D.; Wiehagen, J.

    2014-07-01

    Winchester/Camberley Homes with the Building America program and its NAHB Research Center Industry Partnership collaborated to develop a new set of high performance home designs that could be applicable on a production scale. The new home designs are to be constructed in the mixed humid climate zone four and could eventually apply to all of the builder's home designs to meet or exceed future energy codes or performance-based programs. However, the builder recognized that the combination of new wall framing designs and materials, higher levels of insulation in the wall cavity, and more detailed air sealing to achieve lower infiltrationmore » rates changes the moisture characteristics of the wall system. In order to ensure long term durability and repeatable successful implementation with few call-backs, this report demonstrates through measured data that the wall system functions as a dynamic system, responding to changing interior and outdoor environmental conditions within recognized limits of the materials that make up the wall system. A similar investigation was made with respect to the complete redesign of the heating, cooling, air distribution, and ventilation systems intended to optimize the equipment size and configuration to significantly improve efficiency while maintaining indoor comfort. Recognizing the need to demonstrate the benefits of these efficiency features, the builder offered a new house model to serve as a test case to develop framing designs, evaluate material selections and installation requirements, changes to work scopes and contractor learning curves, as well as to compare theoretical performance characteristics with measured results.« less

  7. Growth and inactivation of Salmonella enterica and Listeria monocytogenes in broth and validation in ground pork meat during simulated home storage abusive temperature and home pan-frying

    PubMed Central

    Wang, Xiang; Lahou, Evy; De Boeck, Elien; Devlieghere, Frank; Geeraerd, Annemie; Uyttendaele, Mieke

    2015-01-01

    Ground pork meat with natural microbiota and inoculated with low initial densities (1–10 or 10–100 CFU/g) of Salmonella enterica or Listeria monocytogenes was stored under abusive temperature at 10°C and thermally treated by a simulated home pan-frying procedure. The growth and inactivation characteristics were also evaluated in broth. In ground pork meat, the population of S. enterica increased by less than one log after 12-days of storage at 10°C, whereas L. monocytogenes increased by 2.3 to 2.8 log units. No unusual intrinsic heat resistance of the pathogens was noted when tested in broth at 60°C although shoulders were observed on the inactivation curves of L. monocytogenes. After growth of S. enterica and L. monocytogenes at 10°C for 5 days to levels of 1.95 log CFU/g and 3.10 log CFU/g, respectively, in ground pork meat, their inactivation in the burger subjected to a simulated home pan-frying was studied. After thermal treatment S. enterica was undetectable but L. monocytogenes was recovered in three out of six of the 25 g burger samples. Overall, the present study shows that data on growth and inactivation of broths are indicative but may underestimate as well as overestimate behavior of pathogens and thus need confirmation in food matrix conditions to assess food safety in reasonably foreseen abusive conditions of storage and usual home pan-frying of meat burgers in Belgium. PMID:26579079

  8. Hood River Passive House, Hood River, Oregon (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    2014-02-01

    The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50%" (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift Housemore » and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.« less

  9. New Whole-House Solutions Case Study: Hood River Passive House

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-02-01

    The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50%" (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift Housemore » and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.« less

  10. Development and validation of a remote home safety protocol.

    PubMed

    Romero, Sergio; Lee, Mi Jung; Simic, Ivana; Levy, Charles; Sanford, Jon

    2018-02-01

    Environmental assessments and subsequent modifications conducted by healthcare professionals can enhance home safety and promote independent living. However, travel time, expense and the availability of qualified professionals can limit the broad application of this intervention. Remote technology has the potential to increase access to home safety evaluations. This study describes the development and validation of a remote home safety protocol that can be used by a caregiver of an elderly person to video-record their home environment for later viewing and evaluation by a trained professional. The protocol was developed based on literature reviews and evaluations from clinical and content experts. Cognitive interviews were conducted with a group of six caregivers to validate the protocol. The final protocol included step-by-step directions to record indoor and outdoor areas of the home. The validation process resulted in modifications related to safety, clarity of the protocol, readability, visual appearance, technical descriptions and usability. Our final protocol includes detailed instructions that a caregiver should be able to follow to record a home environment for subsequent evaluation by a home safety professional. Implications for Rehabilitation The results of this study have several implications for rehabilitation practice The remote home safety evaluation protocol can potentially improve access to rehabilitation services for clients in remote areas and prevent unnecessary delays for needed care. Using our protocol, a patient's caregiver can partner with therapists to quickly and efficiently evaluate a patient's home before they are released from the hospital. Caregiver narration, which reflects a caregiver's own perspective, is critical to evaluating home safety. In-home safety evaluations, currently not available to all who need them due to access barriers, can enhance a patient's independence and provide a safer home environment.

  11. Polycyclic aromatic hydrocarbons and their derivatives in indoor and outdoor air in an eight-home study

    NASA Astrophysics Data System (ADS)

    Chuang, Jane C.; Mack, Gregory A.; Kuhlman, Michael R.; Wilson, Nancy K.

    A pilot field study was performed in Columbus, OH, during the winter of 1986/1987. The objectives were to determine the feasibility of the use of a newly developed quiet sampler in indoor air sampling for particles and semivolatile organic compounds (SVOC) and to measure the concentrations of polycyclic aromatic hydrocarbons (PAH), PAH derivatives, and nicotine in air in selected residences. Eight homes were chosen for sampling on the basis of these characteristics: electric/gas heating system, electric/gas cooking appliances, and the absence/presence of environmental tobacco smoke (ETS). The indoor sampler was equipped with a quartz-fiber filter to collect particles followed by XAD-4 resin to trap SVOC. A PS-1 sampler with a similar sampling module was used outdoors. The indoor air was sampled in the kitchen and living room areas over two consecutive 8-h periods. The outdoor air was sampled concurrently with the indoor samples over a 16-h period. Fifteen PAH, five nitro-PAH, five oxygenated PAH, and three nitrogen heterocyclic compounds were determined in these samples. The most abundant PAH found indoors was naphthalene. The indoor concentrations of PAH derivatives were lower than those of their parent compounds. Average concentrations of all but three target compounds (naphthalene dicarboxylic acid anhydride, pyrene dicarboxylic acid anhydride, and 2-nitrofluoranthene) were higher indoors than outdoors. Environmental tobacco smoke was the most significant influence on indoor pollutant levels. Homes with gas heating systems had higher indoor pollutant levels than homes with electric heating systems. However, the true effects of heating and cooking systems were not characterized as accurately as the effects of ETS because of the small sample sizes and the lack of statistical significance for most pollutant differences in the absence of ETS. The concentrations of PAH marker compounds (phenanthrene, fluoranthene, and pyrene) correlated well with the concentrations of other target compounds. Quinoline and isoquinoline can be used to indicate indoor levels of ETS.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Solar water heating systems are not new, but they have not become prevalent in most of the U.S. Most of the country is cold enough that indirect solar thermal systems are required for freeze protection, and average installed cost of these systems is $9,000 to $10,000 for typical systems on single-family homes. These costs can vary significantly in different markets and with different contractors, and federal and regional incentives can reduce these up-front costs by 50% or more. In western Massachusetts, an affordable housing developer built a community of 20 homes with a goal of approaching zero net energy consumption.more » In addition to excellent thermal envelopes and PV systems, the developer installed a solar domestic water heating system (SDHW) on each home. The Consortium for Advanced Residential Buildings (CARB), a research consortium funded by the U.S. Department of Energy Building America program, commissioned some of the systems, and CARB was able to monitor detailed performance of one system for 28 months.« less

  13. Predicting wood pellet stove ownership and acquisition in Albuquerque, NM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lansford, R.; Skaggs, R.; Owensby, F.

    1994-12-31

    Wood pellet stove (WPS) ownership and acquisition in Albuquerque, New Mexico was predicted using a model of qualitative choice. Using data obtained from a telephone survey, households were divided into four groups: current WPS owners, non-owners considering ownership, non-owners not considering ownership, and those who had not heard of WPS technology. Variables used to predict what category a household will be in include homeowners` socioeconomic and home-heating characteristics. Results indicate few WPS stoves are currently in use in Albuquerque. However, current WPS owners and those considering WPS acquisition tend to have higher incomes, more years of education, larger homes, andmore » use their fireplaces more frequently than average. Clean air regulations in Albuquerque will require changes in home woodburning. The WPS is an efficient and clean device; however, lack of knowledge of WPS technology, satisfaction with current heating systems, and limited awareness of the potential impact of clean air regulations indicate WPS usage in Albuquerque will remain limited.« less

  14. Diabetes in the Desert: What Do Patients Know about the Heat?

    PubMed Central

    Nassar, Adrienne A; Childs, Raymond D; Boyle, Mary E; Jameson, Kimberly A; Fowke, Margaret; Waters, Ken R; Hovan, Michael J; Cook, Curtiss B

    2010-01-01

    Background This study aims to identify self-management strategies used by patients with diabetes in hot weather, examine knowledge of safe temperatures and exposure times, and evaluate comprehension of weather data. Methods Patients attending an endocrinology clinic in southwestern United States were surveyed. Results One hundred fifty-two surveys completed from November 30 to December 31, 2009 werMean patient age was 64 years; diabetes duration e analyzed 15 years; 51% were women 83% had type 2 diabetes, 58% were non Hispanic white, and 77% were on insulin injections. Mean hemoglobin A1c was 7.9%; 38% had hemoglobin A1c values of 8.0% or higher. Patients used an array of personal protective measures during hot weather, and 71% limited heat exposure to less than one hour. Respondents typically took steps to protect their diabetes medication and supplies, but 37% chose to leave medications and supplies at home. Although 73% of respondents had received information regarding the effect of heat on insulin, only 39% had received information about the effect of heat on oral medications, 41% on glucose meters, and 38% on glucose test strips. The temperature at which patients took protective measures varied. Only 55% knew the definition of the heat index. Conclusion Most survey participants took measures to protect themselves from the heat, although gaps in knowledge were evident. Many patients had suboptimal glycemic control, placing them potentially at risk for dehydration during the hottest months. Increased public awareness of this topic is needed, and diabetes education programs should include information about the heat where appropriate. PMID:20920435

  15. Weatherization Works: Final Report of the National Weatherization Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, M.A.

    2001-02-01

    In 1990, the US Department of Energy (DOE) sponsored a comprehensive evaluation of its Weatherization Assistance Program, the nation's largest residential energy conservation program. Oak Ridge National Laboratory (ORNL) managed the five-part study. This document summarizes the findings of the evaluation. Its conclusions are based mainly on data from the 1989 program year. The evaluation concludes that the Program meets the objectives of its enabling legislation and fulfills its mission statement. Specifically, it saves energy, lowers fuel bills, and improves the health and safety of dwellings occupied by low-income people. In addition, the Program achieves its mission in a cost-effectivemore » manner based on each of three perspectives employed by the evaluators. Finally, the evaluation estimates that the investments made in 1989 will, over a 20-year lifetime, save the equivalent of 12 million barrels of oil, roughly the amount of oil added to the Strategic Petroleum Reserve in each of the past several years. The Program's mission is to reduce the heating and cooling costs for low-income families--particularly the elderly, persons with disabilities, and children by improving the energy efficiency of their homes and ensuring their health and safety. Substantial progress has been made, but the job is far from over. The Department of Health and Human Services (HHS) reports that the average low-income family spends 12 percent of its income on residential energy, compared to only 3% for the average-income family. Homes where low-income families live also have a greater need for energy efficiency improvements, but less money to pay for them.« less

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. Aldrich and J. Williamson

    Solar domestic hot water (SDHW) systems have been installed on buildings for decades, but because of relatively high costs they have not achieved significant market penetration in most of the country. As more buildings move towards zero net energy consumption, however, many designers and developers are looking more closely at SDHW. In multifamily buildings especially, SDHW may be more practical for several reasons: (1) When designing for zero net energy consumption, solar water heating may be part of the lowest cost approach to meet water heating loads. (2.) Because of better scale, SDHW systems in multifamily buildings cost significantly lessmore » per dwelling than in single-family homes. (3) Many low-load buildings are moving away from fossil fuels entirely. SDHW savings are substantially greater when displacing electric resistance water heating. (4) In addition to federal tax incentives, some states have substantial financial incentives that dramatically reduce the costs (or increase the benefits) of SDHW systems in multifamily buildings. With support form the U.S. DOE Building America program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in spring of 2014, and CARB has been monitoring performance of the water heating systems since May 2014.« less

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aldrich, Robb; Williamson, James

    Solar domestic hot water (SDHW) systems have been installed on buildings for decades, but because of relatively high costs they have not achieved significant market penetration in most of the country. As more buildings move towards zero net energy consumption, however, many designers and developers are looking more closely at SDHW. In multifamily buildings especially, SDHW may be more practical for several reasons: 1) When designing for zero net energy consumption, solar water heating may be part of the lowest cost approach to meet water heating loads; 2) Because of better scale, SDHW systems in multifamily buildings cost significantly lessmore » per dwelling than in single-family homes; 3) Many low-load buildings are moving away from fossil fuels entirely. SDHW savings are substantially greater when displacing electric resistance water heating; and 4) In addition to federal tax incentives, some states have substantial financial incentives that dramatically reduce the costs (or increase the benefits) of SDHW systems in multifamily buildings. With support from the U.S. DOE Building America program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in spring of 2014, and CARB has been monitoring performance of the water heating systems since May 2014.« less

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Solar domestic hot water (SDHW) systems have been installed on buildings for decades, but because of relatively high costs they have not achieved significant market penetration in most of the country. As more buildings move towards zero net energy consumption, however, many designers and developers are looking more closely at SDHW. In multifamily buildings especially, SDHW may be more practical for several reasons: (1) When designing for zero net energy consumption, solar water heating may be part of the lowest cost approach to meet water heating loads. (2) Because of better scale, SDHW systems in multifamily buildings cost significantly lessmore » per dwelling than in single-family homes. (3) Many low-load buildings are moving away from fossil fuels entirely. SDHW savings are substantially greater when displacing electric resistance water heating. (4) In addition to federal tax incentives, some states have substantial financial incentives that dramatically reduce the costs (or increase the benefits) of SDHW systems in multifamily buildings. With support from the U.S. DOE Building America program, the Consortium for Advanced Residential Buildings (CARB) worked with a developer in western Massachusetts to evaluate a SDHW system on a 12-unit apartment building. Olive Street Development completed construction in spring of 2014, and CARB has been monitoring performance of the water heating systems since May 2014.« less

  19. DOE ZERH Case Study: Habitat for Humanity South Sarasota, Laurel Gardens #794, Nakomis, FL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2015-09-01

    Case study of a DOE 2015 Housing Innovation Award winning affordable home in the hot-humid climate that got a HERS 51 without PV, with foam-filled masonry block walls with .75” rigid foam, furring strips, and foil-faced paper on interior walls; R-20 ocsf in roof of sealed attic, uninsulated slab, 15 SEER 8.0 HSPF heat pump walls for heating and cooling, heat pump water heater.

  20. 16 CFR Appendix D5 to Part 305 - Water Heaters-Heat Pump

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT (âAPPLIANCE LABELING RULEâ) Pt. 305, App. D5... 16 Commercial Practices 1 2013-01-01 2013-01-01 false Water Heaters-Heat Pump D5 Appendix D5 to...

  1. 16 CFR Appendix D5 to Part 305 - Water Heaters-Heat Pump

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT (âAPPLIANCE LABELING RULEâ) Pt. 305, App. D5... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Water Heaters-Heat Pump D5 Appendix D5 to...

  2. Solar Heating and Cooling of Residential Buildings: Design of Systems.

    ERIC Educational Resources Information Center

    Colorado State Univ., Ft. Collins. Solar Energy Applications Lab.

    This is the second of two training courses designed to develop the capability of practitioners in the home building industry to design solar heating and cooling systems. The course is organized in 23 modules to separate selected topics and to facilitate learning. Although a compact schedule of one week is shown, a variety of formats can be…

  3. 45 CFR 96.83 - Increase in maximum amount that may be used for weatherization and other energy-related home repair.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... receive LIHEAP heating, cooling, and crisis assistance benefits that are provided from Federal LIHEAP... crisis assistance benefits received by the grantee's service population that are provided from Federal... source(s) of the data used; (ii) A statement of the grantee's LIHEAP heating, cooling, and crisis...

  4. Validation of the respiratory toxics exposure score (RTES) for chronic obstructive pulmonary disease screening.

    PubMed

    Salameh, Pascale; Khayat, Georges; Waked, Mirna

    2011-12-01

    Our aim is to evaluate the validity of exhaled carbon monoxide (CO) and of a newly-created score as markers of Chronic Obstructive Pulmonary Disease (COPD). The CO level was measured in a derivation subsample of a cross-sectional study and linked to COPD diagnosis; its predictors were evaluated, and a scale was constructed. It was evaluated in a validation subsample and in a clinical setting. Individuals with COPD had higher CO levels than healthy individuals. CO level significant predictors were cigarettes per day, waterpipes per week, lower age, male gender, living close to diesel exhaust, heating home with the use of diesel, and having indoor family smokers. A score composed of CO predictors was able to significantly predict COPD (Ora = 4-7.5). Coupled with the clinical judgment of physicians, this scale would be an excellent low-cost tool for screening COPD, in absence of spirometry.

  5. Identifying Population Vulnerable to Extreme Heat Events in San Jose, California.

    NASA Astrophysics Data System (ADS)

    Rivera, A. L.

    2016-12-01

    The extreme heat days not only make cities less comfortable for living but also they are associated with increased morbidity and mortality. Mapping studies have demonstrated spatial variability in heat vulnerability. A study conducted between 2000 and 2011 in New York City shows that deaths during heat waves was more likely to occur in black individuals, at home in census tracts which received greater public assistance. This map project intends to portray areas in San Jose California that are vulnerable to extreme heat events. The variables considered to build a vulnerability index are: land surface temperature, vegetated areas (NDVI), and people exposed to these area (population density).

  6. A report on the use of thermal scanner data in an operational program for monitoring apparent rooftop temperatures

    NASA Technical Reports Server (NTRS)

    Bjorklund, J.; Schmer, F. A.; Isakson, R. E.

    1975-01-01

    CENGAS, a division of Central Telephone and Utilities Corporation in cooperation with the Remote Sensing Institute, South Dakota State University, is using airborne thermal scanner data to monitor relative rooftop temperatures. Four Nebraska communities and one South Dakota community were surveyed by the Remote Sensing Institute for CENGAS. Thermal scanner data were converted to a film format and the resultant imagery has been successfully employed by CENGAS. The program places emphasis on heat losses resulting from inadequate home insulation, offers CENGAS customers the opportunity to observe a thermogram of their rooftop, and assists homeowners in evaluating insulation needs.

  7. Boeing CST-100 Starliner Landing Simulation

    NASA Image and Video Library

    2018-06-05

    Boeing, NASA and U.S. Army teams rehearse safely bringing the CST-100 Starliner spacecraft home to Earth on Wed., June 6, 2018, at the U.S. Army's White Sands Missile Range in New Mexico. During the detailed landing simulation, engineers, technicians and spaceflight specialists worked through tight timelines and intense heat running through simulations of the spacecraft's landing and recovery, an operation that will cap each Starliner mission. For flight controllers at Mission Control in Houston, the simulation offered the chance to evaluate their own processes and rehearse everything from undocking the Starliner from the space station to communicating with the recovery teams in the field.

  8. Individual Action for Energy Conservation; Committee on Science and Astronautics, U.S. House of Representatives, Ninety-Third Congress, First Session. [Committee Print].

    ERIC Educational Resources Information Center

    Congress of the U.S., Washington, DC. House Committee on Science and Technology.

    This pamphlet lists suggestions for conserving energy. The suggestions are intended for use by citizens. It includes tips on transportation practices emphasizing driving and purchasing an automobile, cooling and heating residential homes, use of home appliances, and preparing for a vacation. The energy saving tips are also aimed at saving money…

  9. DOE ZERH Case Study: High Performance Homes, Chamberlain Court #75, Gettysburg, PA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2015-09-01

    Case study of a DOE 2015 Housing Innovation Award winning production home in the cold climate that got a HERS 37 without PV, or HERS 23 with PV, with R-24 SIP walls, Basement with R-10 under slab, and R-15 unfaced batt on walls, sealed attic with R-49 ocsf under roof deck; ground source heat pump COP 4.4.

  10. Relationship among environmental quality variables, housing variables, and residential needs: a secondary analysis of the relationship among indoor, outdoor, and personal air (RIOPA) concentrations database

    NASA Astrophysics Data System (ADS)

    Garcia, Fausto; Shendell, Derek G.; Madrigano, Jaime

    2017-03-01

    Retrospective descriptive secondary analyses of data from relationships of indoor, outdoor, and personal air (RIOPA) study homes (in Houston, Texas; Los Angeles County, California; and, Elizabeth, New Jersey May 1999-February 2001) were conducted. Data included air exchange rates, associations between indoor and outdoor temperature and humidity, and calculated apparent temperature and humidex. Analyses examined if study homes provided optimum thermal comfort for residents during both heating and cooling seasons when compared to current American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) Standards 62/62.1 and 55. Results suggested outdoor temperature, humidex, and apparent temperature during the cooling season potentially served as indicators of indoor personal exposure to parameters of thermal comfort. Outdoor temperatures, humidex, and apparent temperature during the cooling season had statistically significant predictive abilities in predicting indoor temperature. During the heating season, only humidex in Texas and combined data across study states were statistically significant, but with weaker to moderate predicative ability. The high degree of correlation between outdoor and indoor environmental variables provided support for the validity of epidemiologic studies of weather relying on temporal comparisons. Results indicated most RIOPA study residents experienced thermal comfort; however, many values indicated how several residents may have experienced some discomfort depending on clothing and indoor activities. With climate change, increases in temperature are expected, with more days of extreme heat and humidity and, potentially harsher, longer winters. Homes being built or modernized should be created with the appropriate guidelines to provide comfort for residents daily and in extreme weather events.

  11. Relationship among environmental quality variables, housing variables, and residential needs: a secondary analysis of the relationship among indoor, outdoor, and personal air (RIOPA) concentrations database.

    PubMed

    Garcia, Fausto; Shendell, Derek G; Madrigano, Jaime

    2017-03-01

    Retrospective descriptive secondary analyses of data from relationships of indoor, outdoor, and personal air (RIOPA) study homes (in Houston, Texas; Los Angeles County, California; and, Elizabeth, New Jersey May 1999-February 2001) were conducted. Data included air exchange rates, associations between indoor and outdoor temperature and humidity, and calculated apparent temperature and humidex. Analyses examined if study homes provided optimum thermal comfort for residents during both heating and cooling seasons when compared to current American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) Standards 62/62.1 and 55. Results suggested outdoor temperature, humidex, and apparent temperature during the cooling season potentially served as indicators of indoor personal exposure to parameters of thermal comfort. Outdoor temperatures, humidex, and apparent temperature during the cooling season had statistically significant predictive abilities in predicting indoor temperature. During the heating season, only humidex in Texas and combined data across study states were statistically significant, but with weaker to moderate predicative ability. The high degree of correlation between outdoor and indoor environmental variables provided support for the validity of epidemiologic studies of weather relying on temporal comparisons. Results indicated most RIOPA study residents experienced thermal comfort; however, many values indicated how several residents may have experienced some discomfort depending on clothing and indoor activities. With climate change, increases in temperature are expected, with more days of extreme heat and humidity and, potentially harsher, longer winters. Homes being built or modernized should be created with the appropriate guidelines to provide comfort for residents daily and in extreme weather events.

  12. Using PM2.5 concentrations to estimate the health burden from solid fuel combustion, with application to Irish and Scottish homes

    PubMed Central

    2013-01-01

    Background This study estimates the potential population health burden from exposure to combustion-derived particulate air pollution in domestic settings in Ireland and Scotland. Methods The study focused on solid fuel combustion used for heating and the use of gas for cooking. PM2.5 (particulate matter with an aerodynamic diameter < 2.5 μm) was used as the pollutant mixture indicator. Measured PM2.5 concentrations in homes using solid fuels were adjusted for other sources of PM2.5 by subtracting PM2.5 concentrations in homes using gas for cooking but not solid fuel heating. Health burden was estimated for exposure indoors 6 pm - midnight, or all day (24-hour), by combining estimated attributable annual PM2.5 exposures with (i) selected epidemiological functions linking PM2.5 with mortality and morbidity (involving some re-scaling from PM10 to PM2.5, and adjustments ‘translating’ from concentrations to exposures) and (ii) on the current population exposed and background rates of morbidity and mortality. Results PM2.5 concentrations in coal and wood burning homes were similar to homes using gas for cooking, used here as a baseline (mean 24-hr PM2.5 concentrations 8.6 μg/m3) and so health impacts were not calculated. Concentrations of PM2.5 in homes using peat were higher (24-hr mean 15.6 μg/m3); however, health impacts were calculated for the exposed population in Ireland only; the proportion exposed in Scotland was very small. The assessment for winter evening exposure (estimated annual average increase of 2.11 μg/m3 over baseline) estimated 21 additional annual cases of all-cause mortality, 55 of chronic bronchitis, and 30,100 and 38,000 annual lower respiratory symptom days (including cough) and restricted activity days respectively. Conclusion New methods for estimating the potential health burden of combustion-generated pollution from solid fuels in Irish and Scottish homes are provided. The methodology involves several approximations and uncertainties but is consistent with a wider movement towards quantifying risks in PM2.5 irrespective of source. Results show an effect of indoor smoke from using peat (but not wood or coal) for heating and cooking; but they do not suggest that this is a major public health issue. PMID:23782423

  13. Using PM2.5 concentrations to estimate the health burden from solid fuel combustion, with application to Irish and Scottish homes.

    PubMed

    Galea, Karen S; Hurley, J Fintan; Cowie, Hilary; Shafrir, Amy L; Sánchez Jiménez, Araceli; Semple, Sean; Ayres, Jon G; Coggins, Marie

    2013-06-19

    This study estimates the potential population health burden from exposure to combustion-derived particulate air pollution in domestic settings in Ireland and Scotland. The study focused on solid fuel combustion used for heating and the use of gas for cooking. PM2.5 (particulate matter with an aerodynamic diameter < 2.5 μm) was used as the pollutant mixture indicator. Measured PM2.5 concentrations in homes using solid fuels were adjusted for other sources of PM2.5 by subtracting PM2.5 concentrations in homes using gas for cooking but not solid fuel heating. Health burden was estimated for exposure indoors 6 pm - midnight, or all day (24-hour), by combining estimated attributable annual PM2.5 exposures with (i) selected epidemiological functions linking PM2.5 with mortality and morbidity (involving some re-scaling from PM10 to PM2.5, and adjustments 'translating' from concentrations to exposures) and (ii) on the current population exposed and background rates of morbidity and mortality. PM2.5 concentrations in coal and wood burning homes were similar to homes using gas for cooking, used here as a baseline (mean 24-hr PM2.5 concentrations 8.6 μg/m3) and so health impacts were not calculated. Concentrations of PM2.5 in homes using peat were higher (24-hr mean 15.6 μg/m3); however, health impacts were calculated for the exposed population in Ireland only; the proportion exposed in Scotland was very small. The assessment for winter evening exposure (estimated annual average increase of 2.11 μg/m3 over baseline) estimated 21 additional annual cases of all-cause mortality, 55 of chronic bronchitis, and 30,100 and 38,000 annual lower respiratory symptom days (including cough) and restricted activity days respectively. New methods for estimating the potential health burden of combustion-generated pollution from solid fuels in Irish and Scottish homes are provided. The methodology involves several approximations and uncertainties but is consistent with a wider movement towards quantifying risks in PM2.5 irrespective of source. Results show an effect of indoor smoke from using peat (but not wood or coal) for heating and cooking; but they do not suggest that this is a major public health issue.

  14. 76 FR 12978 - Advisory Committee on the Maternal, Infant and Early Childhood Home Visiting Program Evaluation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-09

    ... Administration for Children and Families Advisory Committee on the Maternal, Infant and Early Childhood Home...: Advisory Committee on the Maternal, Infant and Early Childhood Home Visiting Program Evaluation. Date and... and Early Childhood Home Visiting Program Evaluation will meet for its first session on Wednesday...

  15. Instrumentation at the Decade 80 solar house in Tucson, Arizona

    NASA Technical Reports Server (NTRS)

    1978-01-01

    Modifications, problems and solutions for the instrumentation system that occurred during the period from May through September, 1978, are described. The solar house was built to show the use of copper in home building and to demonstrate the use of solar energy to provide space heating and cooling and domestic hot water. The auxiliary energy sources are electrical resistance heating for the domestic hot water and a gas-fired boiler for space heating and operation of the adsorption air conditioning units.

  16. 24 CFR 3280.1 - Scope.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.1 Scope. This standard covers all equipment and installations in the design, construction, transportation, fire safety, plumbing, heat-producing...

  17. 24 CFR 3280.1 - Scope.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.1 Scope. This standard covers all equipment and installations in the design, construction, transportation, fire safety, plumbing, heat-producing...

  18. 24 CFR 3280.1 - Scope.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.1 Scope. This standard covers all equipment and installations in the design, construction, transportation, fire safety, plumbing, heat-producing...

  19. 24 CFR 3280.1 - Scope.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.1 Scope. This standard covers all equipment and installations in the design, construction, transportation, fire safety, plumbing, heat-producing...

  20. 15 CFR 9.3 - Appliances and equipment included in program.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... and central air conditioners, household refrigerators, home freezers, clothes washers, dishwashers, clothes dryers, kitchen ranges and ovens, water heaters, comfort heating equipment, and television...

  1. 15 CFR 9.3 - Appliances and equipment included in program.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... and central air conditioners, household refrigerators, home freezers, clothes washers, dishwashers, clothes dryers, kitchen ranges and ovens, water heaters, comfort heating equipment, and television...

  2. 15 CFR 9.3 - Appliances and equipment included in program.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... and central air conditioners, household refrigerators, home freezers, clothes washers, dishwashers, clothes dryers, kitchen ranges and ovens, water heaters, comfort heating equipment, and television...

  3. 15 CFR 9.3 - Appliances and equipment included in program.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... and central air conditioners, household refrigerators, home freezers, clothes washers, dishwashers, clothes dryers, kitchen ranges and ovens, water heaters, comfort heating equipment, and television...

  4. 15 CFR 9.3 - Appliances and equipment included in program.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... and central air conditioners, household refrigerators, home freezers, clothes washers, dishwashers, clothes dryers, kitchen ranges and ovens, water heaters, comfort heating equipment, and television...

  5. Cone calorimeter testing of vegetation--an update

    Treesearch

    Robert H. White; David R. Weise; Kurt Mackes; Alison C. Dibble

    2002-01-01

    As part of efforts to address fire problems in the wildland-urban interface, the cone calorimeter is being used to measure the relative flammability of different plant species. In the first two studies, we tested plants used to landscape homes in California and an assortment of plants found in Colorado. Using the effective heat of combustion and the peak heat release...

  6. IMPACT OF HEATING AND AIR CONDITIONING SYSTEM OPERATION AND LEAKAGE ON VENTILATION AND INTERCOMPARTMENT TRANSPORT: STUDIES IN UNOCCUPIED AND OCCUPIED TENNESSEE VALLEY HOMES

    EPA Science Inventory

    Forced-air heating and air conditioning (HAC) systems caused an average and maximum increase in air infiltration rates of 1.8- and 4.3-fold, respectively, during brief whole-house studies of tracer gas decay In 39 occupied houses. An average Increase in air infiltration rate of 0...

  7. Performance of an off-grid solar home in northwestern Vermont

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rawlings, L.K.

    1997-12-31

    In 1995 an off-grid integrated solar home was built in Middlesex, VT for Peter Clark and Gloria DeSousa. This home was included as a pilot home in the US DOE PV:BONUS program to develop factory-built integrated solar homes. The home incorporates a 1.44 KW PV system, 0.6 KW of wind turbine capacity, and very high-efficiency electrical loads. The home also features passive solar design, high-efficiency heating systems, and a greenhouse-based septic treatment system. The performance of the PV system and the wind system, and the total power usage of the household, are measured and recorded by a data acquisition system.more » The home`s electrical loads have operated very efficiently, using on average about one tenth the power used by the average American residence. The PV system has operated reliably and efficiently, providing about 97% of the power needs of the home. The wind turbines have operated efficiently, but the wind regime at the site has not been sufficient to generate more than 1% of the total power needs. The other 2% has been provided by a gasoline backup generator.« less

  8. Home Insulation

    NASA Technical Reports Server (NTRS)

    1994-01-01

    Under the Guaranteed Watt Savers (GWS) system, plans for a new home are computer analyzed for anticipated heat loss and gain. Specifications are specifically designed for each structure and a Smart- House Radiant Barrier is installed. Designed to reflect away 95% of the Sun's radiant energy, the radiant barrier is an adaptation of an aluminum shield used on Apollo spacecraft. On completion of a home, technicians using a machine, check for air tightness, by creating a vacuum in the house and computer calculations that measure the amount of air exchanged. A guarantee that only the specified number kilowatt hours will be used is then provided.

  9. Bread Basket: a gaming model for estimating home-energy costs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    An instructional manual for answering the twenty variables on COLORADO ENERGY's computerized program estimating home energy costs. The program will generate home-energy cost estimates based on individual household data, such as total square footage, number of windows and doors, number and variety of appliances, heating system design, etc., and will print out detailed costs, showing the percentages of the total household budget that energy costs will amount to over a twenty-year span. Using the program, homeowners and policymakers alike can predict the effects of rising energy prices on total spending by Colorado households.

  10. DOE ZERH Case Study: Addison Homes, Cobbler Lane, Simpsonville, SC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2015-09-01

    Case study of a DOE 2015 Housing Innovation Award winning custom home in the mixed humid climate that got a HERS 41 without PV, with 2x4 16” on-center walls with 1 inch rigid foam, a sealed conditioned crawl space insulated on inside with 2 inches poly iso, a vented attic with R-38 blown fiberglass, a central heat pump with fresh air intake.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    A. Herk; Poerschke, A.; Beach, R.

    In 2012-2013, IBACOS worked with a builder, Brookfield Homes in Denver, Colorado, to design and construct a Passive House certified model home. IBACOS used several modeling programs and calculation methods to complete the final design package along with Brookfield's architect KGA Studio. This design package included upgrades to the thermal enclosure, basement insulation, windows, and heating, ventilation, and air conditioning. Short-term performance testing in the Passive House was done during construction and after construction.

  12. Science at Home: Measuring a Thermophysical Property of Water with a Microwave Oven

    ERIC Educational Resources Information Center

    Levine, Zachary H.

    2018-01-01

    An attempt to calibrate a conventional oven led to making a measurement of a thermophysical property of water using items found in the author's home. Specifically, the ratio of the energy required to heat water from the melting point to boiling to the energy required to completely boil away the water is found to be 5.7. This may be compared to the…

  13. The Home Depot Upgrades its Corporate Building Prototype

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2013-03-01

    The Home Depot partnered with the Department of Energy (DOE) to develop and implement solutions to build new, low-energy buildings that are at least 50% below Standard 90.1-2007 of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), the American National Standards Institute (ANSI), and the Illuminating Engineering Society of North America (IESNA) as part of DOE’s Commercial Building Partnerships (CBP) Program.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    This case study describes a DOE Zero Energy Ready Home in Old Greenwich, CT, that scored HERS 40 without PV and HERS 27 with PV. This 4,100 ft2 custom home has 13-inch ICF basement walls and 11-inch ICF above-grade walls with a closed-cell spray foam-insulated roof deck, and a continuously running ERV. The house has a dual-fuel heat pump, an instantaneous condensing water heater, and 4.5-kW solar shingles.

  15. Home in the heat: Dramatic seasonal variation in home range of desert golden eagles informs management for renewable energy development

    Treesearch

    Melissa Braham; Tricia Miller; Adam E. Duerr; Michael Lanzone; Amy Fesnock; Larry LaPre; Daniel Driscoll; Todd Katzner

    2015-01-01

    Renewable energy is expanding quickly with sometimes dramatic impacts to species and ecosystems. To understand the degree to which sensitive species may be impacted by renewable energy projects, it is informative to know how much space individuals use and how that space may overlap with planned development. We used global positioning system-global system for mobile...

  16. Technology Solutions for New Manufactured Homes: Idaho, Oregon, and Washington Manufactured Home Builders (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    2013-11-01

    The Building America Partnership for Improved Residential Construction, the Bonneville Power Administration (BPA), and Northwest Energy Works (NEW), the current Northwest Energy Efficient Manufactured Housing Program (NEEM) administrator, have been collaborating to conduct research on new specifications that would improve on the energy requirements of a NEEM home. In its role as administrator, NEW administers the technical specs, performs research and engineering analysis, implements ongoing construction quality management procedures, and maintains a central database with home tracking. This project prototyped and assessed the performances of cost-effective high performance building assemblies and mechanical systems that are not commonly deployed in themore » manufacturing setting. The package of measures is able to reduce energy used for space conditioning, water heating and lighting by 50 percent over typical manufactured homes produced in the northwest.« less

  17. Home Electrical Safety Checklist

    MedlinePlus

    ... any object? YES: Unwrap cords. Wrapped cords trap heat that normally escapes loose cords, which can lead to melting or weakening of insulation. Are cords attached to anything (wall, baseboard, etc) ...

  18. Measuring Infiltration Rates in Homes as a Basis for Understanding Indoor Air Quality

    NASA Astrophysics Data System (ADS)

    Jerz, G. G.; Lamb, B. K.; Pressley, S. N.; O'Keeffe, P.; Fuchs, M.; Kirk, M.

    2015-12-01

    Infiltration rates, or the rate of air exchange, of houses are important to understand because ventilation can be a dominate factor in determining indoor air quality. There are chemicals that are emitted from surfaces or point sources inside the home which are harmful to humans; these chemicals come from various objects including furniture, cleaning supplies, building materials, gas stoves, and the surrounding environment. The use of proper ventilation to cycle cleaner outdoor air into the house can be crucial for maintaining healthy living conditions in the home. At the same time, there can also be outdoor pollutants which infiltrate the house and contribute to poor indoor air quality. In either case, it is important to determine infiltration rates as a function of outdoor weather conditions, the house structure properties and indoor heating and cooling systems. In this work, the objective is to measure ventilation rates using periodic releases of a tracer gas and measuring how quickly the tracer concentration decays. CO2 will be used as the tracer gas because it is inert and harmless at low levels. An Arduino timer is connected to a release valve which controls the release of 9.00 SLPM of CO2 into the uptake vent within the test home. CO2 will be released until there is at least a 200 to 300 ppm increase above ambient indoor levels. Computers with CO2 sensors and temperature/pressure sensors attached will be used to record data from different locations within the home which will continuously record data up to a week. The results from these periodic ventilation measurements will be analyzed with respect to outdoor wind and temperature conditions and house structure properties. The data will be used to evaluate an established indoor air quality model.

  19. Geothermal energy program overview

    NASA Astrophysics Data System (ADS)

    1991-12-01

    The mission of the Geothermal Energy Program is to develop the science and technology necessary for tapping our nation's tremendous heat energy sources contained within the Earth. Geothermal energy is a domestic energy source that can produce clean, reliable, cost-effective heat and electricity for our nation's energy needs. Geothermal energy - the heat of the Earth - is one of our nation's most abundant energy resources. In fact, geothermal energy represents nearly 40 percent of the total U.S. energy resource base and already provides an important contribution to our nation's energy needs. Geothermal energy systems can provide clean, reliable, cost-effective energy for our nation's industries, businesses, and homes in the form of heat and electricity. The U.S. Department of Energy's (DOE) Geothermal Energy Program sponsors research aimed at developing the science and technology necessary for utilizing this resource more fully. Geothermal energy originates from the Earth's interior. The hottest fluids and rocks at accessible depths are associated with recent volcanic activity in the western states. In some places, heat comes to the surface as natural hot water or steam, which have been used since prehistoric times for cooking and bathing. Today, wells convey the heat from deep in the Earth to electric generators, factories, farms, and homes. The competitiveness of power generation with lower quality hydrothermal fluids, geopressured brines, hot dry rock, and magma (the four types of geothermal energy), still depends on the technical advancements sought by DOE's Geothermal Energy Program.

  20. Systematic review of the health and social determinants and outcomes of home cooking: protocol.

    PubMed

    Mills, Susanna; White, Martin; Robalino, Shannon; Wrieden, Wendy; Brown, Heather; Adams, Jean

    2015-03-28

    The United Kingdom (UK) and wider world are experiencing an obesity epidemic, with lower socio-economic groups disproportionately affected. Dietary quality is also socio-economically patterned, with an estimated quarter of observed inequalities in UK mortality due to inequalities in diet. Food preparation and eating patterns clearly have an impact on dietary intake and hence health. A growing body of evidence indicates that out of home food consumption and eating ready meals may be associated with negative outcomes. However, to date no systematic reviews have assessed the health and social determinants and outcomes of home cooking. Here, home cooking refers to the combination of actions required for preparing hot or cold foods at home, including combining, mixing and often heating ingredients. A systematic review of peer-reviewed literature on home cooking will be undertaken. Studies will be considered for inclusion if they present qualitative or quantitative data on participants from high/very high human development index countries, including all relevant study designs. No language or date of publication restrictions will be applied. Determinants will be considered as factors that influence behaviour and outcomes as potential advantages and disadvantages of engaging in home cooking. Electronic databases of peer-reviewed journal articles covering health, psychology, social sciences and consumer practices will be searched. Published postgraduate theses will also be considered for inclusion. Additional strategies to identify relevant studies will be used, such as citation searches of included articles, evaluation of references from relevant reviews and included articles and the 'related/similar to' function found in certain databases. Two independent researchers will be involved in literature screening (10% at first screen and 100% at second screen), data extraction and quality appraisal. Studies included in the review will be analysed by thematic synthesis and narrative synthesis, as appropriate for the nature of the data retrieved. This review will provide key empirical evidence to inform the development of recommendations for public health policy makers and practitioners to encourage healthier home food preparation, thereby impacting on dietary-related health. This protocol has been registered with the PROSPERO international prospective register of systematic reviews, reference CRD42014013984 .

  1. Simulation of tree shade impacts on residential energy use for space conditioning in Sacramento

    NASA Astrophysics Data System (ADS)

    Simpson, J. R.; McPherson, E. G.

    Tree shade reduces summer air conditioning demand and increases winter heating load by intercepting solar energy that would otherwise heat the shaded structure. We evaluate the magnitude of these effects here for 254 residential properties participating in a utility sponsored tree planting program in Sacramento, California. Tree and building characteristics and typical weather data are used to model hourly shading and energy used for space conditioning for each building for a period of one year. There were an average of 3.1 program trees per property which reduced annual and peak (8 h average from 1 to 9 p.m. Pacific Daylight Time) cooling energy use 153 kWh (7.1%) and 0.08 kW (2.3%) per tree, respectively. Annual heating load increased 0.85 GJ (0.80 MBtu, 1.9%) per tree. Changes in cooling load were smaller, but percentage changes larger, for newer buildings. Averaged over all homes, annual cooling savings of 15.25 per tree were reduced by a heating penalty of 5.25 per tree, for net savings of 10.00 per tree from shade. We estimate an annual cooling penalty of 2.80 per tree and heating savings of 6.80 per tree from reduced wind speed, for a net savings of 4.00 per tree, and total annual savings of 14.00 per tree (43.00 per property). Results are found to be consistent with previous simulations and the limited measurements available.

  2. Numerical Simulation of a Solar Domestic Hot Water System

    NASA Astrophysics Data System (ADS)

    Mongibello, L.; Bianco, N.; Di Somma, M.; Graditi, G.; Naso, V.

    2014-11-01

    An innovative transient numerical model is presented for the simulation of a solar Domestic Hot Water (DHW) system. The solar collectors have been simulated by using a zerodimensional analytical model. The temperature distributions in the heat transfer fluid and in the water inside the tank have been evaluated by one-dimensional models. The reversion elimination algorithm has been used to include the effects of natural convection among the water layers at different heights in the tank on the thermal stratification. A finite difference implicit scheme has been implemented to solve the energy conservation equation in the coil heat exchanger, and the energy conservation equation in the tank has been solved by using the finite difference Euler implicit scheme. Energy conservation equations for the solar DHW components models have been coupled by means of a home-made implicit algorithm. Results of the simulation performed using as input data the experimental values of the ambient temperature and the solar irradiance in a summer day are presented and discussed.

  3. The Clinimetric Properties of Instruments Measuring Home Hazards for Older People at Risk of Falling: A Systematic Review.

    PubMed

    Romli, Muhammad Hibatullah; Mackenzie, Lynette; Lovarini, Meryl; Tan, Maw Pin; Clemson, Lindy

    2018-03-01

    Home hazards are associated with falls among older people living in the community. However, evaluating home hazards is a complex process as environmental factors vary according to geography, culture, and architectural design. As a result, many health practitioners commonly use nonstandardized assessment methods that may lead to inaccurate findings. Thus, the aim of this systematic review was to identify standardized instruments for evaluating home hazards related to falls and evaluate the clinimetric properties of these instruments for use by health practitioners. A systematic search was conducted in the Medline, CINAHL, AgeLine, Web of Science databases, and the University of Sydney Library CrossSearch Engine. Study screening, assessment, and quality ratings were conducted independently. Thirty-six studies were identified describing 19 instruments and three assessment techniques. The clinimetric properties varied between instruments. The Home Falls and Accidents Screening Tool, Home Safety Self-Assessment Tool, In-Home Occupational Performance Evaluation, and Westmead Home Safety Assessment were the instruments with high potential for evaluating home hazards associated with falls. Health practitioners can choose the most appropriate instruments for their practice, as a range of standardized instruments with established clinimetric properties are available.

  4. Wind power systems for individual applications. [electric power supplies for homes

    NASA Technical Reports Server (NTRS)

    Clews, H. M.

    1973-01-01

    A small windpower system is described which is suitable for electrifying a house. The self-contained unit consists of a two kilowatt wind driven generator, a set of 19 storage batteries, a small dc to ac inverter, and a gasoline generator for use as an emergency backup system in case of prolonged calm periods. Cost effectiveness of the electricity generated by this windmill system comes out to about 15 cents per kilowatt hour - assuming a 10 year life for the batteries and a 20 year life for the other components. Some other small windpower systems are also described, and it is shown that a windpowered generator in the 15- to 25-kilowatt output range coupled to a direct heated water storage system is able to heat a typical New England home.

  5. Initial Business Case Analysis of Two Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes - Update to Include Evaluation of Impact of Including a Humidifier Option

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baxter, Van D

    2007-02-01

    The long range strategic goal of the Department of Energy's Building Technologies (DOE/BT) Program is to create, by 2020, technologies and design approaches that enable the construction of net-zero energy homes at low incremental cost (DOE/BT 2005). A net zero energy home (NZEH) is a residential building with greatly reduced needs for energy through efficiency gains, with the balance of energy needs supplied by renewable technologies. While initially focused on new construction, these technologies and design approaches are intended to have application to buildings constructed before 2020 as well resulting in substantial reduction in energy use for all building typesmore » and ages. DOE/BT's Emerging Technologies (ET) team is working to support this strategic goal by identifying and developing advanced heating, ventilating, air-conditioning, and water heating (HVAC/WH) technology options applicable to NZEHs. In FY05 ORNL conducted an initial Stage 1 (Applied Research) scoping assessment of HVAC/WH systems options for future NZEHs to help DOE/BT identify and prioritize alternative approaches for further development. Eleven system concepts with central air distribution ducting and nine multi-zone systems were selected and their annual and peak demand performance estimated for five locations: Atlanta (mixed-humid), Houston (hot-humid), Phoenix (hot-dry), San Francisco (marine), and Chicago (cold). Performance was estimated by simulating the systems using the TRNSYS simulation engine (Solar Energy Laboratory et al. 2006) in two 1800-ft{sup 2} houses--a Building America (BA) benchmark house and a prototype NZEH taken from BEopt results at the take-off (or crossover) point (i.e., a house incorporating those design features such that further progress towards ZEH is through the addition of photovoltaic power sources, as determined by current BEopt analyses conducted by NREL). Results were summarized in a project report, HVAC Equipment Design options for Near-Zero-Energy Homes--A Stage 2 Scoping Assessment, ORNL/TM-2005/194 (Baxter 2005). The 2005 study report describes the HVAC options considered, the ranking criteria used, and the system rankings by priority. In 2006, the two top-ranked options from the 2005 study, air-source and ground-source versions of a centrally ducted integrated heat pump (IHP) system, were subjected to an initial business case study. The IHPs were subjected to a more rigorous hourly-based assessment of their performance potential compared to a baseline suite of equipment of legally minimum efficiency that provided the same heating, cooling, water heating, demand dehumidification, and ventilation services as the IHPs. Results were summarized in a project report, Initial Business Case Analysis of Two Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes, ORNL/TM-2006/130 (Baxter 2006a). The present report is an update to that document which summarizes results of an analysis of the impact of adding a humidifier to the HVAC system to maintain minimum levels of space relative humidity (RH) in winter. The space RH in winter has direct impact on occupant comfort and on control of dust mites, many types of disease bacteria, and 'dry air' electric shocks. Chapter 8 in ASHRAE's 2005 Handbook of Fundamentals (HOF) suggests a 30% lower limit on RH for indoor temperatures in the range of {approx}68-69F based on comfort (ASHRAE 2005). Table 3 in chapter 9 of the same reference suggests a 30-55% RH range for winter as established by a Canadian study of exposure limits for residential indoor environments (EHD 1987). Harriman, et al (2001) note that for RH levels of 35% or higher, electrostatic shocks are minimized and that dust mites cannot live at RH levels below 40%. They also indicate that many disease bacteria life spans are minimized when space RH is held within a 30-60% range. From the foregoing it is reasonable to assume that a winter space RH range of 30-40% would be an acceptable compromise between comfort considerations and limitation of growth rates for dust mites and many bacteria. In addition it reports some corrections made to the simulation models used in order to correct some errors in the TRNSYS building model for Atlanta and in the refrigerant pressure drop calculation in the water-to-refrigerant evaporator module of the ORNL Heat Pump Design Model (HPDM) used for the IHP analyses. These changes resulted in some minor differences between IHP performance as reported in Baxter (2006) and in this report.« less

  6. Initial Business Case Analysis of Two Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes -- Update to Include Analyses of an Economizer Option and Alternative Winter Water Heating Control Option

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baxter, Van D

    2006-12-01

    The long range strategic goal of the Department of Energy's Building Technologies (DOE/BT) Program is to create, by 2020, technologies and design approaches that enable the construction of net-zero energy homes at low incremental cost (DOE/BT 2005). A net zero energy home (NZEH) is a residential building with greatly reduced needs for energy through efficiency gains, with the balance of energy needs supplied by renewable technologies. While initially focused on new construction, these technologies and design approaches are intended to have application to buildings constructed before 2020 as well resulting in substantial reduction in energy use for all building typesmore » and ages. DOE/BT's Emerging Technologies (ET) team is working to support this strategic goal by identifying and developing advanced heating, ventilating, air-conditioning, and water heating (HVAC/WH) technology options applicable to NZEHs. Although the energy efficiency of heating, ventilating, and air-conditioning (HVAC) equipment has increased substantially in recent years, new approaches are needed to continue this trend. Dramatic efficiency improvements are necessary to enable progress toward the NZEH goals, and will require a radical rethinking of opportunities to improve system performance. The large reductions in HVAC energy consumption necessary to support the NZEH goals require a systems-oriented analysis approach that characterizes each element of energy consumption, identifies alternatives, and determines the most cost-effective combination of options. In particular, HVAC equipment must be developed that addresses the range of special needs of NZEH applications in the areas of reduced HVAC and water heating energy use, humidity control, ventilation, uniform comfort, and ease of zoning. In FY05 ORNL conducted an initial Stage 1 (Applied Research) scoping assessment of HVAC/WH systems options for future NZEHs to help DOE/BT identify and prioritize alternative approaches for further development. Eleven system concepts with central air distribution ducting and nine multi-zone systems were selected and their annual and peak demand performance estimated for five locations: Atlanta (mixed-humid), Houston (hot-humid), Phoenix (hot-dry), San Francisco (marine), and Chicago (cold). Performance was estimated by simulating the systems using the TRNSYS simulation engine (Solar Energy Laboratory et al. 2006) in two 1800-ft{sup 2} houses--a Building America (BA) benchmark house and a prototype NZEH taken from BEopt results at the take-off (or crossover) point (i.e., a house incorporating those design features such that further progress towards ZEH is through the addition of photovoltaic power sources, as determined by current BEopt analyses conducted by NREL). Results were summarized in a project report, HVAC Equipment Design options for Near-Zero-Energy Homes--A Stage 2 Scoping Assessment, ORNL/TM-2005/194 (Baxter 2005). The 2005 study report describes the HVAC options considered, the ranking criteria used, and the system rankings by priority. In 2006, the two top-ranked options from the 2005 study, air-source and ground-source versions of an integrated heat pump (IHP) system, were subjected to an initial business case study. The IHPs were subjected to a more rigorous hourly-based assessment of their performance potential compared to a baseline suite of equipment of legally minimum efficiency that provided the same heating, cooling, water heating, demand dehumidification, and ventilation services as the IHPs. Results were summarized in a project report, Initial Business Case Analysis of Two Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes, ORNL/TM-2006/130 (Baxter 2006). The present report is an update to that document. Its primary purpose is to summarize results of an analysis of the potential of adding an outdoor air economizer operating mode to the IHPs to take advantage of free cooling (using outdoor air to cool the house) whenever possible. In addition it provides some additional detail for an alternative winter water heating/space heating (WH/SH) control strategy briefly described in the original report and corrects some minor errors.« less

  7. Correlates of hot day air-conditioning use among middle-aged and older adults with chronic heart and lung diseases: the role of health beliefs and cues to action.

    PubMed

    Richard, Lucie; Kosatsky, Tom; Renouf, Annie

    2011-02-01

    Extreme ambient heat is a serious public health threat, especially for the elderly and persons with pre-existing health conditions. Although much of the excess mortality and morbidity associated with extreme heat is preventable, the adoption of effective preventive strategies is limited. The study reported here tested the predictive power of selected components of the Health Belief Model for air-conditioning (AC) use among 238 non-institutionalized middle-aged and older adults with chronic heart failure and/or chronic obstructive pulmonary disease living in Montréal, Canada. Respondents were recruited through clinics (response rate 71%) and interviews were conducted in their homes or by telephone. Results showed that 73% of participants reported having a home air conditioner. The average number of hours spent per 24-hour period in air-conditioned spaces during heat waves was 14.5 hours (SD = 9.4). Exploratory structural equation modeling showed that specific beliefs about the benefits of and drawbacks to AC as well as internal cues to action were predictive of its level of use, whereas the perceived severity of the effects of heat on health was not. The findings are discussed in light of the need to adequately support effective response to extreme heat in this vulnerable population.

  8. Research and development of a heat-pump water heater. Volume 2. R and D task reports

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dunning, R.L.; Amthor, F.R.; Doyle, E.J.

    1978-08-01

    The heat pump water heater is a device that works much like a window air conditioner except that heat from the home is pumped into a water tank rather than to the outdoors. The objective established for the device is to operate with a Coefficient of Performance (COP) of 3 or, an input of one unit of electric energy would create three units of heat energy in the form of hot water. With such a COP, the device would use only one-third the energy and at one-third the cost of a standard resistance water heater. This Volume 2 contains themore » final reports of the three major tasks performed in Phase I. In Task 2, a market study identifies the future market and selects an initial target market and channel of distribution, all based on an analysis of the parameters affecting feasibility of the device and the factors that will affect its market acceptance. In the Task 3 report, the results of a design and test program to arrive at final designs of heat pumps for both new water heaters and for retrofitting existing water heaters are presented. In the Task 4 report, a plan for an extensive field demonstration involving use in actual homes is presented. Volume 1 contains a final summary report of the information in Volume 2.« less

  9. Class and Home Problems. Identify-Solve-Broadcast Your Own Transport Phenomenon: Student-Created YouTube Videos to Foster Active Learning in Mass and Heat Transfer

    ERIC Educational Resources Information Center

    Wen, Fei; Khera, Eshita

    2016-01-01

    Despite the instinctive perception of mass and heat transfer principles in daily life, productive learning in this course continues to be one of the greatest challenges for undergraduate students in chemical engineering. In an effort to enhance student learning in classroom, we initiated an innovative active-learning method titled…

  10. Home Energy Saver

    Science.gov Websites

    possible reasons. Want information on the technical assumptions and methods behind the site ? - Documentation on appliances, heating/cooling methods, and the tariff analysis methods is all available here

  11. Tapping The Sun's Energy

    ERIC Educational Resources Information Center

    Lee, David G.

    1974-01-01

    Describes several successful attempts to utilize solar energy for heating and providing electrical energy for homes. Indicates that more research and development are needed, especially in the area of large scale usage. (SLH)

  12. 78 FR 62305 - Fire Prevention Week, 2013

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-16

    .... We should be cautious while cooking, using electrical appliances, and heating our homes. Those who... skilled professionals battle walls of flame, put themselves in the paths of unpredictable wildfires, and...

  13. 24 CFR 3280.501 - Scope.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Thermal Protection § 3280.501 Scope. This subpart sets forth the requirements for condensation control, air infiltration, thermal insulation and certification for heating and comfort cooling. ...

  14. DOE ZERH Case Study: Palo Duro Homes, Via del Cielo, Santa Fe, NM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2015-09-01

    Case study of a DOE 2015 Housing Innovation Award winning production home in the mixed-dry climate that got a HERS 48 without PV, with 2x6 24” on center walls with R-21 blown fiberglass; slab foundation with R-10 under slab and R-5rigid foam at slab edge; vented attic with R-75 blown fiberglass; ducted minisplit heat pump 16.5 SEER, 9.5 HSPF.

  15. Efficient Solutions for Existing Homes Case Study: Demonstration House of Cold-Climate Solutions for Affordable Housing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    T. Schirber, C. Ojczyk, and R. Jacobson

    2016-05-01

    Single family homes in urban areas that are available for renovation by nonprofit developers are often in rough shape (1MM to 2MM nationally). Budgeting has historically focused on improving homes to meet basic housing standards. A rising interest in the long-term impact of homeownership has introduced the need to balance basic needs with home performance. This demonstration project aims to help nonprofit affordable housing developers become familiar with three Building America performance measures, the installation processes, and impacts and benefits of each. A story and a half home in North Minneapolis, MN was presented by Urban Homeworks our local nonprofitmore » partner. The team helped them install three researched upgrade measures: exterior roof insulation or 'overcoat,' exterior foundation insulation, or 'excavationless', and a combined space and water heating HVAC system or 'combi.'« less

  16. Home theater projectors: the next big thing?

    NASA Astrophysics Data System (ADS)

    Chinnock, Christopher B.

    2002-04-01

    The business presentation market has traditionally been the mainstay of the projection business, but as these users find the projectors work well at showing movies at home, interest in the home entertainment market is heating up. The idea of creating a theater environment in the home, complete with big screen projector and quality audio system, is not new. Wealthy patrons have been doing it for years. But can the concept be extended to ordinary living rooms? Many think so. Already pioneers like Sony, InFocus, Toshiba and Plus Vision are offering first generation products - and others will follow. But this market will require projectors that have different performance characteristics than those designed for data projection. In this paper, we will discuss how the requirements for a home theater projector differ from those of a data projector. We will provide updated information on who is doing what in this segment and give some insight into the growth potential.

  17. Lakeland Habitat for Humanity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gilbride, Theresa L.

    2009-03-30

    This is a case study of the Lakeland, FLorida, Habitat for Humanity affiliate, which has partnered with DOE's Building America program to homes that achieve energy savings of 30% or more over the Building America baseline home (a home built to the 1993 Model Energy Code). The article includes a description of the energy-efficiency features used. The Lakeland affiliate built several of its homes with ducts in conditioned space, which minimizes heat losses and gains. They also used high-efficiency SEER 14 air conditioners; radiant barriers in the roof to keep attics cooler; above-code high-performance dual-pane vinyl-framed low-emissivity windows; a passivemore » fresh air duct to the air handler; and duct blaster and blower door testing of every home to ensure the home's air tightness. This case study was also prepared as a flier titled "High Performance Builder Spotlight: Lakeland Habitat for Humanity, Lakeland, Florida,: which was cleared as PNNL-SA-59068 and distributed at the International Builders’ Show Feb 13-16, 2008, in Orlando, Florida.« less

  18. System Security And Monitoring On Smart Home Using Android

    NASA Astrophysics Data System (ADS)

    Romadhon, A. S.

    2018-01-01

    Home security system is needed for homeowners who have a lot of activities, as a result, they often leave the house without locking the door and even leave the house in a state of lights that are not lit. In order to overcome this case, a system that can control and can monitor the state of the various devices contained in the house or smart home system is urgently required. The working principle of this smart home using android is when the homeowner sends a certain command using android, the command will be forwarded to the microcontroller and then it will be executed based on the parameters that have been determined. For example, it can turn off and on the light using android app. In this study, testing was conducted to a smart home prototype which is equipped with light bulbs, odour sensors, heat sensors, ultrasonic sensors, LDR, buzzer and camera. The test results indicate that the application has been able to control all the sensors of home appliances well.

  19. 78 FR 53150 - Advisory Committee on the Maternal, Infant and Early Childhood Home Visiting Program Evaluation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-28

    ... and Services Administration Advisory Committee on the Maternal, Infant and Early Childhood Home... Maternal, Infant and Early Childhood Home Visiting Program Evaluation (MIECHVE). Authority: Section 10(a)(2... meeting: Name: Advisory Committee on the Maternal, Infant, and Early Childhood Home Visiting Program...

  20. 76 FR 71979 - Advisory Committee on the Maternal, Infant and Early Childhood Home Visiting Program Evaluation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-21

    ... and Services Administration Advisory Committee on the Maternal, Infant and Early Childhood Home...: Name: Advisory Committee on the Maternal, Infant and Early Childhood Home Visiting Program Evaluation..., DC 20005. (202) 289-7600. The Advisory Committee on the Maternal, Infant and Early Childhood Home...

  1. Developing a semi/automated protocol to post-process large volume, High-resolution airborne thermal infrared (TIR) imagery for urban waste heat mapping

    NASA Astrophysics Data System (ADS)

    Rahman, Mir Mustafizur

    In collaboration with The City of Calgary 2011 Sustainability Direction and as part of the HEAT (Heat Energy Assessment Technologies) project, the focus of this research is to develop a semi/automated 'protocol' to post-process large volumes of high-resolution (H-res) airborne thermal infrared (TIR) imagery to enable accurate urban waste heat mapping. HEAT is a free GeoWeb service, designed to help Calgary residents improve their home energy efficiency by visualizing the amount and location of waste heat leaving their homes and communities, as easily as clicking on their house in Google Maps. HEAT metrics are derived from 43 flight lines of TABI-1800 (Thermal Airborne Broadband Imager) data acquired on May 13--14, 2012 at night (11:00 pm--5:00 am) over The City of Calgary, Alberta (˜825 km 2) at a 50 cm spatial resolution and 0.05°C thermal resolution. At present, the only way to generate a large area, high-spatial resolution TIR scene is to acquire separate airborne flight lines and mosaic them together. However, the ambient sensed temperature within, and between flight lines naturally changes during acquisition (due to varying atmospheric and local micro-climate conditions), resulting in mosaicked images with different temperatures for the same scene components (e.g. roads, buildings), and mosaic join-lines arbitrarily bisect many thousands of homes. In combination these effects result in reduced utility and classification accuracy including, poorly defined HEAT Metrics, inaccurate hotspot detection and raw imagery that are difficult to interpret. In an effort to minimize these effects, three new semi/automated post-processing algorithms (the protocol) are described, which are then used to generate a 43 flight line mosaic of TABI-1800 data from which accurate Calgary waste heat maps and HEAT metrics can be generated. These algorithms (presented as four peer-reviewed papers)---are: (a) Thermal Urban Road Normalization (TURN)---used to mitigate the microclimatic variability within a thermal flight line based on varying road temperatures; (b) Automated Polynomial Relative Radiometric Normalization (RRN)---which mitigates the between flight line radiometric variability; and (c) Object Based Mosaicking (OBM)---which minimizes the geometric distortion along the mosaic edge between each flight line. A modified Emissivity Modulation technique is also described to correct H-res TIR images for emissivity. This combined radiometric and geometric post-processing protocol (i) increases the visual agreement between TABI-1800 flight lines, (ii) improves radiometric agreement within/between flight lines, (iii) produces a visually seamless mosaic, (iv) improves hot-spot detection and landcover classification accuracy, and (v) provides accurate data for thermal-based HEAT energy models. Keywords: Thermal Infrared, Post-Processing, High Spatial Resolution, Airborne, Thermal Urban Road Normalization (TURN), Relative Radiometric Normalization (RRN), Object Based Mosaicking (OBM), TABI-1800, HEAT, and Automation.

  2. Home Start Evaluation Study. Interim Report II: Program Analysis. Revised Draft.

    ERIC Educational Resources Information Center

    Deloria, Dennis; And Others

    This document is the second in a series of evaluative reports directed to evaluation needs of Home Start planners and administrators. It focuses on implementation data about programs gathered during local site visits conducted in the spring and fall of 1972. The two basic evaluative questions asked are: (1) What was Home Start intended by its…

  3. Subsystem design package for Solar II collector

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The requirements for the design and performance of the Solar 2 Collector Subsystem developed for use in solar heating of single family residences and mobile homes are presented. Installation drawings are included.

  4. Burn Wise Funding

    EPA Pesticide Factsheets

    EPA is working with federal, state, tribal and local agencies to find and promote viable funding options to replace wood-burning appliances with cleaner home heating. Includes Guide to Financing Options for Wood-burning Appliance Changeouts.

  5. A Fleet of Low-Cost Sensor Based Air Quality Monitors Is Used to Measure Carbon Dioxide and Carbon Monoxide in Two Settings: In the Ambient Environment to Explore the Regional-Scale Spatial Variability of These Compounds Via a Distributed Network, and in Homes to Investigate How Heating during Winter Months can Impact Indoor Air Quality.

    NASA Astrophysics Data System (ADS)

    Casey, J. G.; Hannigan, M.; Collier, A. M.; Coffey, E.; Piedrahita, R.

    2016-12-01

    Affordable, small, portable, quiet tools to measure atmospheric trace gases and air quality enable novel experimental design and new findings. Members of the Hannigan Lab at the University of Colorado in Boulder have been working over the last few years to integrate emerging affordable gas sensors into such an air quality monitor. Presented here are carbon monoxide (CO) and carbon dioxide (CO2) measurements from two field experiments that utilized these tools. In the first experiment, ten air quality monitors were located northeast of Boulder throughout the Denver Julesburg oil and gas basin. The Colorado Department of Health and Environment has several air quality monitoring sites in this broader region, each in an Urban center. One goal of the experiment was to determine whether or not significant spatial variability of EPA criteria pollutants like CO, exists on a sub-regulatory monitoring grid scale. Another goal of the experiment was to compare rural sampling locations with urban sites. The monitors collected continuous data (sampling every 15 seconds) at each location over the course of several months. Our sensor calibration procedures are presented along with our observations and an analysis of the spatial and temporal variability in CO and CO2. In the second experiment, we used eight of our air quality monitors to better understand how home heating fuel type can impact indoor air quality in two communities on the Navajo Nation. We sought to compare air quality in homes using one of four different fuels for heat (wood, wood plus coal, pellet, and gas). There are many factors that contribute to indoor air quality and the impact of an emission source, like a woodstove, within a home. Having multiple, easily deployable, air quality monitors allowed us to account for many of these factors. We sampled four homes at a time, aiming for one home from each of our fuel groups in each sampling period. We sampled inside and outside of each home for a period of 3-4 days. In this way, we hoped to account for possible weather and outdoor air quality biases. CO and CO2 were measured and are put into context with acceptable levels. During periods when there were no emissions of CO and CO2, we used their rates of decay to calculate the home's air exchange rate via the tracer gas technique. The air exchange rate was then used to calculate emission rates for CO.

  6. Energy-related emissions from telework.

    PubMed

    Kitou, Erasmia; Horvath, Arpad

    2003-08-15

    Telework is a growing phenomenon that is thought to save energy and air emissions. This paper applies a systems model to telework and nontelework scenarios in order to quantify greenhouse gas and other air emissions from transportation, heating, cooling, lighting, and electronic and electrical equipment use both at the company and the home office. Using United States data, a WWW-based, scalable decision-support tool was created to evaluate the environmental impacts of teleworkers. For a typical case reflecting United States teleworker patterns, the analysis found that telework has the potential to reduce air emissions. However, Monte Carlo simulation employed to perform a probabilistic analysis over a set of likely parameters has revealed that telework may not affect equally the emissions of all types of pollutants. It may decrease CO2, NOx, SO2, PM10, and CO but not N2O and CH4 emissions. Therefore, the scope and goal of telework programs must be defined early in the implementation process. Work-related transportation (commuting) impacts could be reduced as a result of telework; however, home-related impacts due to an employee spending additional time at home could potentially offset these reductions. Company office-related impacts may not be reduced unless the office space is shared with other employees during telework days or eliminated entirely. In states with high telework potential (California, Georgia, Illinois, New York, Texas), telework could save emissions, but it would depend on commuting and climatic patterns and the electricity mix. Environmentally beneficial telework programs are found to depend mainly on commuting patterns, induced energy usage, and characteristics of the office and home space and equipment use.

  7. Best Practices Case Study: CDC Realty, Inc. - Centennial Terrace, Tucson, AZ

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2009-10-01

    Case study on CDC Realty who achieved HERS 70 by putting ducts in a conditioned attic insulated along the roofline with netted cellulose, R-5 rigid insulated sheathing over R-19 wall cavity insulation, and deep overhangs and low-e windows to minimize solar heat gain. The 17 homes are solar-ready for solar water heating and five have integral collector storage hot water systems on the roof.

  8. Eldercare at Home: Pain

    MedlinePlus

    ... of pain, and may be best treated with physical therapy without taking any medicine at all. Pain can ... medicine and non-medicine strategies. Treatments such as physical therapy, massage, heat and/or cold packs, exercise, and ...

  9. Genetics Home Reference: acral peeling skin syndrome

    MedlinePlus

    ... heat, humidity and other forms of moisture, and friction. The underlying skin may be temporarily red and ... tend to be heavily exposed to moisture and friction. Learn more about the gene associated with acral ...

  10. Home-Start between Childhood and Maturity: A Programme Evaluation.

    ERIC Educational Resources Information Center

    Terpstra, Linda; van Dijke, Anke

    A crucial question for evaluating nationally or internationally implemented programs is whether local adaptations detract from program quality and effectiveness. An evaluation examined the program successes and challenges encountered in the first 5 years of Home-Start in the Netherlands, a home-based family support program for families with young…

  11. Energy resource alternatives competition. Progress report for the period February 1, 1975--December 31, 1975. [Space heating and cooling, hot water, and electricity for homes, farms, and light industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matzke, D.J.; Osowski, D.M.; Radtke, M.L.

    1976-01-01

    This progress report describes the objectives and results of the intercollegiate Energy Resource Alternatives competition. The one-year program concluded in August 1975, with a final testing program of forty student-built alternative energy projects at the Sandia Laboratories in Albuquerque, New Mexico. The goal of the competition was to design and build prototype hardware which could provide space heating and cooling, hot water, and electricity at a level appropriate to the needs of homes, farms, and light industry. The hardware projects were powered by such nonconventional energy sources as solar energy, wind, biologically produced gas, coal, and ocean waves. The competitionmore » rules emphasized design innovation, economic feasibility, practicality, and marketability. (auth)« less

  12. Results of a Survey of Residential Home Heating Fuel and Stove Type and Use in the Shiprock Area of the Navajo Nation

    USGS Publications Warehouse

    Bunnell, Joseph E.; Garcia, Linda V.

    2008-01-01

    For many Navajo people, coal provides an affordable and convenient means of home heating. However, coal combustion results in the formation and mobilization of materials that are known risk factors for respiratory and other diseases. The level of respiratory morbidity among the Navajo people is higher than can be explained by usual epidemiological risk factors. The Shiprock area of the Navajo Nation is somewhat unique in that atmospheric thermal inversions trap air pollution low to the ground, especially in winter. There are two large mine mouth coal-fired power plants located in the vicinity, with a third plant in the planning stages. Both of the existing power plants are exempt from regulation under the U.S. Environmental Protection Agency 1990 Amendments to the Clean Air Act due to their age. The purpose of this survey was to assess the fuel and stove type and use, and document other household characteristics that might be related to the exposure of potentially toxic coal combustion products. A total of 137 surveys was conducted in English and Navajo to ascertain and document fuel usage and the type, size and conditions of heating stoves used in both traditional and modern homes. Results have been presented to the community at the Shiprock Chapter in the Navajo language. To increase public awareness, ways to properly use and store coal and to improve stove function and ventilation were also shared.

  13. How Does EIA Estimate Energy Consumption and End Uses in U.S. Homes?

    EIA Publications

    2011-01-01

    The Energy Information Administration (EIA) administers the Residential Energy Consumption Survey (RECS) to a nationally representative sample of housing units. Specially trained interviewers collect energy characteristics on the housing unit, usage patterns, and household demographics. This information is combined with data from energy suppliers to these homes to estimate energy costs and usage for heating, cooling, appliances and other end uses information critical to meeting future energy demand and improving efficiency and building design.

  14. Domestic Aerial Surveillance and Homeland Security: Should Americans Fear the Eye in the Sky?

    DTIC Science & Technology

    2014-03-01

    In this case, an individual in North Dakota barricaded himself inside his property after officials ordered him to return six cows that wondered onto...www.hsdl.org/?view&did=737816. 24 Donald F. Kettl, System under Stress : Homeland Security and American Politics (Washington, DC: CQ, 2007), 113-115...police used a thermal imaging device to detect abnormal levels of heat radiating from the home of Danny Kyllo. Officials entered his home without a

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    The first certified Zero Energy Ready Home in Georgia was honored in the Custom Builder category of the 2014 Housing Innovation Awards. The 2,811-ft2, two-story custom home has 2x6 advanced framed walls filled with R-20 of open-cell spray foam, plus an R-6.6 insulated coated OSB sheathing. Also included is electronic monitoring equipment that tracks the PV, solar thermal water heater, ERV, mini-split heat pump with three indoor heads, solar water heater, and LED and CFL lighting.

  16. The OPERA trial: a protocol for the process evaluation of a randomised trial of an exercise intervention for older people in residential and nursing accommodation

    PubMed Central

    2011-01-01

    Background The OPERA trial is large cluster randomised trial testing a physical activity intervention to address depression amongst people living in nursing and residential homes for older people. A process evaluation was commissioned alongside the trial and we report the protocol for this process evaluation. Challenges included the cognitive and physical ability of the participants, the need to respect the privacy of all home residents, including study non-participants, and the physical structure of the homes. Evaluation activity had to be organised around the structured timetable of homes, leaving limited opportunities for data collection. The aims of this process evaluation are to provide findings that will assist in the interpretation of the clinical trial results, and to inform potential implementation of the physical activity intervention on a wider scale. Methods/design Quantitative data on recruitment of homes and individuals is being collected. For homes in the intervention arm, data on dose and fidelity of the intervention delivered; including individual rates of participation in exercise classes are collected. In the control homes, uptake and delivery of depression awareness training is monitored. These data will be combined with qualitative data from an in-depth study of a purposive sample of eight homes (six intervention and two control). Discussion Although process evaluations are increasingly funded alongside trials, it is still rare to see the findings published, and even rarer to see the protocol for such an evaluation published. Process evaluations have the potential to assist in interpreting and understanding trial results as well as informing future roll-outs of interventions. If such evaluations are funded they should also be reported and reviewed in a similar way to the trial outcome evaluation. Trial Registration ISRCTN No: ISRCTN43769277 PMID:21288341

  17. Chemical heat pump

    DOEpatents

    Greiner, Leonard

    1984-01-01

    A chemical heat pump system is disclosed for use in heating and cooling structures such as residences or commercial buildings. The system is particularly adapted to utilizing solar energy, but also increases the efficiency of other forms of thermal energy when solar energy is not available. When solar energy is not available for relatively short periods of time, the heat storage capacity of the chemical heat pump is utilized to heat the structure, as during nighttime hours. The design also permits home heating from solar energy when the sun is shining. The entire system may be conveniently rooftop located. In order to facilitate installation on existing structures, the absorber and vaporizer portions of the system may each be designed as flat, thin wall, thin pan vessels which materially increase the surface area available for heat transfer. In addition, this thin, flat configuration of the absorber and its thin walled (and therefore relatively flexible) construction permits substantial expansion and contraction of the absorber material during vaporization and absorption without generating voids which would interfere with heat transfer.

  18. Chemical heat pump

    DOEpatents

    Greiner, Leonard

    1981-01-01

    A chemical heat pump system is disclosed for use in heating and cooling structures such as residences or commercial buildings. The system is particularly adapted to utilizing solar energy, but also increases the efficiency of other forms of thermal energy when solar energy is not available. When solar energy is not available for relatively short periods of time, the heat storage capacity of the chemical heat pump is utilized to heat the structure, as during nighttime hours. The design also permits home heating from solar energy when the sun is shining. The entire system may be conveniently rooftop located. In order to facilitate installation on existing structures, the absorber and vaporizer portions of the system may each be designed as flat, thin wall, thin pan vessels which materially increase the surface area available for heat transfer. In addition, this thin, flat configuration of the absorber and its thin walled (and therefore relatively flexible) construction permits substantial expansion and contraction of the absorber material during vaporization and absorption without generating voids which would interfere with heat transfer.

  19. Chemical heat pump

    DOEpatents

    Greiner, Leonard

    1984-01-01

    A chemical heat pump system is disclosed for use in heating and cooling structures such as residences or commercial buildings. The system is particularly adapted to utilizing solar energy, but also increases the efficiency of other forms of thermal energy when solar energy is not available. When solar energy is not available for relatively short periods of time, the heat storage capacity of the chemical heat pump is utilized to heat the structure, as during nighttime hours. The design also permits home heating from solar energy when the sun is shining. The entire system may be conveniently rooftop located. In order to facilitate intallation on existing structures, the absorber and vaporizer portions of the system may each be designed as flat, thin wall, thin pan vessels which materially increase the surface area available for heat transfer. In addition, this thin, flat configuration of the absorber and its thin walled (and therefore relatively flexible) construction permits substantial expansion and contraction of the absorber material during vaporization and absorption without generating voids which would interfere with heat transfer.

  20. Chemical heat pump

    DOEpatents

    Greiner, Leonard

    1984-01-01

    A chemical heat pump system is disclosed for use in heating and cooling structures such as residences or commercial buildings. The system is particularly adapted to utilizing solar energy, but also increases the efficiency of other forms of thermal energy when solar energy is not available. When solar energy is not available for relatively short periods of time, the heat storage capacity of the chemical heat pump is utilized to heat the structure, as during nighttime hours. The design also permits home heating from solar energy when the sun is shining. The entire system may be conveniently rooftop located. In order to faciliate installation on existing structures, the absorber and vaporizer portions of the system may each be designed as flat, thin wall, thin pan vessels which materially increase the surface area available for heat transfer. In addition, this thin, flat configuration of the absorber and its thin walled (and therefore relatively flexible) construction permits substantial expansion and contraction of the absorber material during vaporization and absorption without generating voids which would interfere with heat transfer.

  1. Reducing Energy Use in Existing Homes by 30%: Learning From Home Performance with ENERGY STAR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liaukus, C.

    2014-12-01

    The improvement of existing homes in the United States can have a much greater impact on overall residential energy use than the construction of highly efficient new homes. There are over 130 million existing housing units in the U.S., while annually new construction represents less than two percent of the total supply (U.S. Census Bureau, 2013). Therefore, the existing housing stock presents a clear opportunity and responsibility for Building America (BA) to guide the remodeling and retrofit market toward higher performance existing homes. There are active programs designed to improve the energy performance of existing homes. Home Performance with ENERGYmore » STAR (HPwES) is a market-rate program among them. BARA's research in this project verified that the New Jersey HPwES program is achieving savings in existing homes that meet or exceed BA's goal of 30%. Among the 17 HPwES projects with utility data included in this report, 15 have actual energy savings ranging from 24% to 46%. Further, two of the homes achieved that level of energy savings without the costly replacement of heating and cooling equipment, which indicates that less costly envelope packages could be offered to consumers unable to invest in more costly mechanical packages, potentially creating broader market impact.« less

  2. The Parent-Child Home Program in Western Manitoba: A 20-Year Evaluation

    ERIC Educational Resources Information Center

    Gfellner, Barbara M.; McLaren, Lorraine; Metcalfe, Arron

    2008-01-01

    This article is a 20-year evaluation of the Parent-Child Home Program (PCHP) of Child and Family Services in Western Manitoba. Following Levenstein's (1979, 1988) approach, home visitors model parent-child interchanges using books and toys to enhance children's cognitive development through appropriate parenting behaviors. The evaluation provides…

  3. Small Changes Yield Large Results at NIST's Net-Zero Energy Residential Test Facility.

    PubMed

    Fanney, A Hunter; Healy, William; Payne, Vance; Kneifel, Joshua; Ng, Lisa; Dougherty, Brian; Ullah, Tania; Omar, Farhad

    2017-12-01

    The Net-Zero Energy Residential Test Facility (NZERTF) was designed to be approximately 60 % more energy efficient than homes meeting the 2012 International Energy Conservation Code (IECC) requirements. The thermal envelope minimizes heat loss/gain through the use of advanced framing and enhanced insulation. A continuous air/moisture barrier resulted in an air exchange rate of 0.6 air changes per hour at 50 Pa. The home incorporates a vast array of extensively monitored renewable and energy efficient technologies including an air-to-air heat pump system with a dedicated dehumidification cycle; a ducted heat-recovery ventilation system; a whole house dehumidifier; a photovoltaic system; and a solar domestic hot water system. During its first year of operation the NZERTF produced an energy surplus of 1023 kWh. Based on observations during the first year, changes were made to determine if further improvements in energy performance could be obtained. The changes consisted of installing a thermostat that incorporated control logic to minimize the use of auxiliary heat, using a whole house dehumidifier in lieu of the heat pump's dedicated dehumidification cycle, and reducing the ventilation rate to a value that met but did not exceed code requirements. During the second year of operation the NZERTF produced an energy surplus of 2241 kWh. This paper describes the facility, compares the performance data for the two years, and quantifies the energy impact of the weather conditions and operational changes.

  4. Building America Case Study: Multifamily Central Heat Pump Water Heaters, Davis, California

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16-month period were then used to validate a TRNSYS simulation model. The TRNSYSmore » model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.« less

  5. Boys of Coshocton: Part One

    ScienceCinema

    Feikert, Ray; Estep, Meriem; Blair, Olive; Fortune, Sam

    2018-05-07

    Sam Fortune Jr. lost his job during Christmas week 2007. Hope finally came more than a year later when an ad in the local paper announced a job for heating technicians through a local home weatherization program.

  6. Evaluation of the Costs of Caring for the Senile Demented Elderly: A Pilot Study.

    ERIC Educational Resources Information Center

    Hu, Teh-wei; And Others

    1986-01-01

    Evaluated economic costs for nursing home patients and elderly living in their own homes. Using time records compiled by nurses or family members, the costs incurred annually in caring for a senile demented elderly person at home were estimated to average $11,735, and in a nursing home, $22,458. (Author/BL)

  7. National Home Start Evaluation. Interim Report V: Case Studies.

    ERIC Educational Resources Information Center

    Jerome, Chris H.; And Others

    One of a series of documents on the evaluation of the National Home Start (NHS) program this third year interim report of case studies describes program efforts and successes with 16 Home Start families throughout the nation. A federally funded demonstration program, NHS is aimed at providing home-based services (such as health, education,…

  8. Home intervention as a tool for nursing care: evaluation of the satisfaction of the elderly.

    PubMed

    Nogueira, Iara Sescon; Previato, Giselle Fernanda; Scolari, Giovana Aparecida de Souza; Gomes, Ana Caroline Oliveira; Carreira, Ligia; Baldissera, Vanessa Denardi Antoniassi

    2017-04-06

    To evaluate the results of home nursing interventions according to the satisfaction of the elderly users. Ex-post facto evaluative, qualitative and descriptive research, conducted from November 2015 to January 2016 with 12 dependent elderly individuals accompanied by an extension project in the city of Maringá, PR, Brazil. Data were collected after home interventions based on the Single-User Treatment Project, by means of semi-structured interviews subjected to content analysis and the theoretical framework of Donabedian. The following thematic categories emerged: "home nursing intervention: synonymous with joy, distraction and bonding" and" home nursing intervention: health and lifestyle transformations". The home nursing interventions had positive results that signal the quality of the provided care.

  9. Foster youth evaluate the performance of group home services in California.

    PubMed

    Green, Rex S; Ellis, Peter T

    2008-05-01

    In 2003 foster youth employed by a foster youth advocacy organization suggested that an evaluation of group home services to foster youth be conducted in Alameda County, California. This report presents the development and conduct of this evaluation study; how funding was obtained; and how foster youth were hired, trained, and employed to produce a timely and informative evaluation of the performance of 32 group homes where some of the foster youth formerly resided. The results of the study are described in another paper. This report contributes to evaluation practice in the newly emerging field of youth-led evaluations. The achievements of this project in utilizing group home clients to evaluate services with which they were familiar may stimulate other evaluators to develop similar projects, thereby enriching the development of our youth and promoting more informative evaluation findings.

  10. A solar house in Provence: Impressions and reflections after five years

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Randall, D.G.

    1989-01-01

    This house was fully described in SunWorld, Volume 7, Number 3 (Fall 1983). It was not a research project so comprehensive readings of conditions, analyses and heat balances have not been attempted. However, the author has accumulated much data from which some approximations can be made. Being essentially a home for him and his wife, some of this report is subjective. Developments which are described are: domestic hot water system, main collector array, solar porch fans, control systems, pool heating and space heating make-up. The author also discusses active versus passive, humidity, frost, economics, and maintenance.

  11. Technology Solutions for New and Existing Homes Case Study: Addressing Multifamily Piping Losses with Solar Hot Water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D. Springer, M. Seitzler, and C. Backman

    2016-12-01

    Sun Light & Power, a San Francisco Bay Area solar design-build contractor, teamed with the U.S. Department of Energy’s Building America partner the Alliance for Residential Building Innovation (ARBI) to study this heat-loss issue. The team added three-way valves to the solar water heating systems for two 40-unit multifamily buildings. In these systems, when the stored solar hot water is warmer than the recirculated hot water returning from the buildings, the valves divert the returning water to the solar storage tank instead of the water heater. This strategy allows solar-generated heat to be applied to recirculation heat loss in additionmore » to heating water that is consumed by fixtures and appliances.« less

  12. Solar residential heating and cooling system development test program

    NASA Technical Reports Server (NTRS)

    Humphries, W. R.; Melton, D. E.

    1974-01-01

    A solar heating and cooling system is described, which was installed in a simulated home at Marshall Space Flight Center. Performance data are provided for the checkout and initial operational phase for key subsystems and for the total system. Valuable information was obtained with regard to operation of a solar cooling system during the first summer of operation. Areas where improvements and modifications are required to optimize such a system are discussed.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    Case study of a DOE 2015 Housing Innovation Award winning custom home in the cold climate that got a HERS 30 without PV, with 2x8 24” on center walls with blown fiberglass and 4” polysio rigid foam; basement with 2” XPS interior, 4” under slab, 4” exterior of foundation wall; vented attic with R-100 blown cellulose; wo air-to-air heat pumps SEER 14.1; HSPF 9.6; heat pump water heater.

  14. BETTER DUCT SYSTEMS FOR HOME HEATING AND COOLING.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ANDREWS,J.

    This is a series of six guides intended to provide a working knowledge of residential heating and cooling duct systems, an understanding of the major issues concerning efficiency, comfort, health, and safety, and practical tips on installation and repair of duct systems. These guides are intended for use by contractors, system designers, advanced technicians, and other HVAC professionals. The first two guides are also intended to be accessible to the general reader.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    Case study of a DOE 2015 Housing Innovation Award winning production home in the mixed-dry climate that got a HERS 44 without PV, or HERS -2 with PV, with 2x4 walls 16” on center walls with R-15 cavity plus 1” EPS exterior rigid foam, slab on grade with R-10 slab edge; unvented attic with R-38 blown fiberglass netted to underside of roof deck; 19 SEER heat pump; heat pump water heater; 100% LED.

  16. DOE ZERH Case Study: Charles Thomas Homes, Anna Model, Omaha, NE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    Case study of a DOE 2015 Housing Innovation Award winning custom home in the cold climate that got a HERS 48 without PV, with 2x6 24” on center walls with R-23 blown fiberglass, ocsf at rim joists, basement with plus 2x4 stud walls with R-23 blown fiberglass, with R-20 around slab, R-38 under slab; a vented attic with R-100 blown cellulose; 95% AFUE furnace, 14 SEER AC, ERV; heat pump water heater.

  17. The Role of the Air Force Environmental Health Nurse in Long-Term Health Problems in Natural Disasters.

    DTIC Science & Technology

    1983-06-01

    Heat Crisis Volcanoes Snows torms THE EN AND PRE-DISASTER PLANNING ..................**o 30 THEESHN AND DISASTER RISK SURVY............. .... ... 34...the mortality rate would have ? en even lower if victims had stayed home or abandoned their cars to escape the storm; the homes of 11 of the vehicu- lar...allow the EN to begin immediate assessment. They are designed to answer the following questions: l(a) Is there a demographic difference between the victim

  18. Novel Interventions for Heat/Exercise Induced Sudden Death and Fatigue

    DTIC Science & Technology

    2014-12-01

    T., Ji, R., Hanna,A., Joshi, A. Long, C., Oakes, J., Tran,T., Corona ,B., Lorca,S., Ingalls, C., Narkar, V., Lanner,J.,Bayle,J., Durham, W. and...hydration and discharged home. His CK levels remained increased (>2000 U/L) for 2 months before gradually decreasing to the 1000 U/L range. After...followed, and the patient was discharged home still in pain with a CK of 3800 U/L after a total of 5 hospital days wherein he received only IV hydration

  19. DOE ZERH Case Study: Clifton View Homes, Marine Drive and Port Hadlcok, Coupeville and Port Hadlock WA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2015-09-01

    Case study of two DOE 2015 Housing Innovation Award winning custom homes in the marine climate that got HERS 39 and 38 without PV or HERS 2-12 and -9 with PV, with 6.5” SIP walls and 10.25” SIP roof; 11.75 ICF around slab, R-20 rigid foam under slab; radiant floor heat and passive design; air-to-water heatpump, fresh air intake with fan, triple-pane windows, 100% LED.

  20. Validating Savings Claims of Cold Climate Zero Energy Ready Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williamson, J.; Puttagunta, S.

    This report details the validation methods used to analyze consumption at each of these homes. It includes a detailed end-use examination of consumptions from the following categories: 1) Heating, 2) Cooling, 3) Lights, Appliances, and Miscellaneous Electric Loads (LAMELS) along with Domestic Hot Water Use, 4) Ventilation, and 5) PV generation. A utility bill disaggregation method, which allows a crude estimation of space conditioning loads based on outdoor air temperature, was also performed and the results compared to the actual measured data.

  1. DOE ZERH Case Study: Amaris Homes, Fishers Circle, Vadnais Heights, MN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    Case study of a DOE 2015 Housing Innovation Award winning custom home in the cold climate that got a HERS 47 without PV or HERS 22 with PV, with 2x4 24” on-center walls with 1 inch rigid foam plus 3” ccsf in cavity, a slab on grade foundation with 2” rigid foam under and around slab, a vented attic with with 2” ccsf plus R-15 blown cellulose, a central heat pump and HRV.

  2. Northwest Energy Efficient Manufactured Housing Program: High Performance Manufactured Home Prototyping and Construction Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hewes, Tom; Peeks, Brady

    2013-11-01

    The Building America Partnership for Improved Residential Construction, the Bonneville Power Administration (BPA), and Northwest Energy Works (NEW), the current Northwest Energy Efficient Manufactured Housing Program (NEEM) administrator, have been collaborating to conduct research on new specifications that would improve on the energy requirements of a NEEM home. In its role as administrator, NEW administers the technical specs, performs research and engineering analysis, implements ongoing construction quality management procedures, and maintains a central database with home tracking. This project prototyped and assessed the performances of cost-effective high performance building assemblies and mechanical systems that are not commonly deployed in themore » manufacturing setting. The package of measures is able to reduce energy used for space conditioning, water heating and lighting by 50 percent over typical manufactured homes produced in the northwest.« less

  3. Northwest Energy Efficient Manufactured Housing Program: High Performance Manufactured Home Prototyping and Construction Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hewes, Tom; Peeks, Brady

    2013-11-01

    The Building America Partnership for Improved Residential Construction, the Bonneville Power Administration (BPA), and Northwest Energy Works (NEW), the current Northwest Energy Efficient Manufactured Housing Program (NEEM) administrator, have been collaborating to conduct research on new specifications that would improve on the energy requirements of a NEEM home. In its role as administrator, NEW administers the technical specs, performs research and engineering analysis, implements ongoing construction quality management procedures, and maintains a central database with home tracking. This project prototyped and assessed the performances of cost-effective high performance building assemblies and mechanical systems that are not commonly deployed in themore » manufacturing setting. The package of measures is able to reduce energy used for space conditioning, water heating and lighting by 50% over typical manufactured homes produced in the northwest.« less

  4. Burden and Risk Factors for Cold-Related Illness and Death in New York City

    PubMed Central

    Lane, Kathryn; Ito, Kazuhiko; Johnson, Sarah; Gibson, Elizabeth A.; Matte, Thomas

    2018-01-01

    Exposure to cold weather can cause cold-related illness and death, which are preventable. To understand the current burden, risk factors, and circumstances of exposure for illness and death directly attributed to cold, we examined hospital discharge, death certificate, and medical examiner data during the cold season from 2005 to 2014 in New York City (NYC), the largest city in the United States. On average each year, there were 180 treat-and-release emergency department visits (average annual rate of 21.6 per million) and 240 hospital admissions (29.6 per million) for cold-related illness, and 15 cold-related deaths (1.8 per million). Seventy-five percent of decedents were exposed outdoors. About half of those exposed outdoors were homeless or suspected to be homeless. Of the 25% of decedents exposed indoors, none had home heat and nearly all were living in single-family or row homes. The majority of deaths and illnesses occurred outside of periods of extreme cold. Unsheltered homeless individuals, people who use substances and become incapacitated outdoors, and older adults with medical and psychiatric conditions without home heat are most at risk. This information can inform public health prevention strategies and interventions. PMID:29601479

  5. 2015 RECS Square Footage Methodology

    EIA Publications

    2017-01-01

    The square footage, or size, of a home is an important characteristic in understanding its energy use. The amounts of energy used for major end uses such as space heating and air conditioning are strongly related to the size of the home. The Residential Energy Consumption Survey (RECS), conducted by the U.S. Energy Information Administration (EIA), collects information about the size of the responding housing units as part of the data collection protocol. The methods used to collect data on housing unit size produce square footage estimates that are unique to RECS because they are designed to capture the energy-consuming space within a home. This document discusses how the 2015 RECS square footage estimates were produced.

  6. Evaluating "The Safe Living Guide": A Home Hazard Checklist for Seniors

    ERIC Educational Resources Information Center

    Sorcinelli, Andrea; Shaw, Lynn; Freeman, Andrew; Cooper, Kim

    2007-01-01

    Purpose: The purpose of this study was to evaluate the utility and reliability of a home hazard checklist published in Health Canada, "The Safe Living Guide: A Guide to Home Safety for Seniors" (2003). Methods: 76 community-dwelling seniors evaluated the guide, and inter-rater reliability was determined through comparison of ratings of…

  7. National Home Start Evaluation Interim Report VII. Twenty-Month Program Analysis and Findings.

    ERIC Educational Resources Information Center

    Love, John M.; And Others

    This interim evaluation report focuses on process (formative) and outcome (summative) data collected in spring 1975 on the National Home Start Program. Home Start, a federally-funded 3-year (1972-1975) home-based demonstration program for low-income families with 3- to 5-year-old children was designed to enhance a mother's skills in dealing with…

  8. National Home Start Evaluation Interim Report VI. Twelve-Month Program Issues, Outcomes and Costs.

    ERIC Educational Resources Information Center

    Goodrich, Nancy; And Others

    This report assesses the progress of the six summative Home Start projects as evaluation families completed their first twelve months of enrollment. Home Start, a federally-funded 3-year (1972-1975) home-based demonstration program for low-income families with 3- to 5-year-old children was designed to enhance a mother's skills in dealing with her…

  9. What are Hydrofluorocarbons?

    ScienceCinema

    None

    2018-06-13

    Hydrofluorocarbons are the most common refrigerants found in vapor compression systems that heat and cool our homes. They are also thousands of times more potent than carbon dioxide. Learn about the Energy Department's efforts to help phase down these fluorinated gases.

  10. Residential solar hot water system--Tempe, Arizona

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Domestic hot water for single story home is heated by two 4 by 8 foot solar collectors. Solar energy saved 5.54 million Btu in six month period; savings with increased water consumption would be significantly higher.

  11. 16 CFR Appendix I to Part 305 - Heating Performance and Cost for Central Air Conditioners

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... ACTS OF CONGRESS RULE CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT (âAPPLIANCE LABELING...

  12. 16 CFR Appendix I to Part 305 - Heating Performance and Cost for Central Air Conditioners

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... ACTS OF CONGRESS RULE CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT (âAPPLIANCE LABELING...

  13. 16 CFR Appendix I to Part 305 - Heating Performance and Cost for Central Air Conditioners

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... ACTS OF CONGRESS RULE CONCERNING DISCLOSURES REGARDING ENERGY CONSUMPTION AND WATER USE OF CERTAIN HOME APPLIANCES AND OTHER PRODUCTS REQUIRED UNDER THE ENERGY POLICY AND CONSERVATION ACT (âAPPLIANCE LABELING...

  14. 75 FR 45148 - Buy American Exceptions Under the American Recovery and Reinvestment Act of 2009

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-02

    ... Homes and mini-split ductless Heating, Ventilation and Air Conditioning (HVAC) systems at the Mary... that the relevant manufactured goods (tankless water heaters and mini-split ductless HVAC systems) are...

  15. What are Hydrofluorocarbons?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2016-11-28

    Hydrofluorocarbons are the most common refrigerants found in vapor compression systems that heat and cool our homes. They are also thousands of times more potent than carbon dioxide. Learn about the Energy Department's efforts to help phase down these fluorinated gases.

  16. Unintentional carbon monoxide poisoning following a winter storm--Washington, January 1993.

    PubMed

    1993-02-19

    Carbon monoxide (CO) poisoning was a major health consequence of a severe storm that struck the Puget Sound region of western Washington state the morning of January 20, 1993. Wind gusts up to 94 miles per hour interrupted electrical power for an estimated 776,000 residents, and during the 4 nights following the storm, temperatures fell to near freezing. Because of the use of alternative sources of energy for indoor cooking and home heating, the risk of exposure to CO increased for many persons. This report summarizes cases of storm-related CO poisoning among persons who were initially evaluated at Seattle's Harborview Medical Center (HMC) or who were referred to the Virginia Mason Medical Center (VMMC) for hyperbaric oxygen therapy.

  17. New Whole-House Solutions Case Study: Northwest Energy Efficient Manufactured Housing Program High-Performance Test Homes - Pacific Northwest

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2015-05-01

    This project represents the third phase of a multi-year effort to develop and bring to market a High Performance Manufactured Home (HPMH). In this project, the Northwest Energy Efficient Manufactured Housing Program worked with Building America Partnership for Improved Residential Construction and Bonneville Power Administration to help four factory homebuilders build prototype zero energy ready manufactured homes, resulting in what is expected to be a 30% savings relative to the Building America Benchmark. (The actual % savings varies depending on choice of heating equipment and climate zone). Previous phases of this project created a HPMH specification and prototyped individual measuresmore » from the package to obtain engineering approvals and develop preliminary factory construction processes. This case study describes the project team's work during 2014 to build prototype homes to the HPMH specifications and to monitor the homes for energy performance and durability. Monitoring is expected to continue into 2016.« less

  18. Navajo Coal Combustion and Respiratory Health Near Shiprock, New Mexico

    PubMed Central

    Bunnell, Joseph E.; Garcia, Linda V.; Furst, Jill M.; Lerch, Harry; Olea, Ricardo A.; Suitt, Stephen E.; Kolker, Allan

    2010-01-01

    Indoor air pollution has been identified as a major risk factor for acute and chronic respiratory diseases throughout the world. In the sovereign Navajo Nation, an American Indian reservation located in the Four Corners area of the USA, people burn coal in their homes for heat. To explore whether/how indoor coal combustion might contribute to poor respiratory health of residents, this study examined respiratory health data, identified household risk factors such as fuel and stove type and use, analyzed samples of locally used coal, and measured and characterized fine particulate airborne matter inside selected homes. In twenty-five percent of homes surveyed coal was burned in stoves not designed for that fuel, and indoor air quality was frequently found to be of a level to raise concerns. The average winter 24-hour PM2.5 concentration in 20 homes was 36.0 μg/m3. This is the first time that PM2.5 has been quantified and characterized inside Navajo reservation residents' homes. PMID:20671946

  19. Navajo Coal Combustion and Respiratory Health Near Shiprock, New Mexico

    DOE PAGES

    Bunnell, Joseph E.; Garcia, Linda V.; Furst, Jill M.; ...

    2010-01-01

    Indoormore » air pollution has been identified as a major risk factor for acute and chronic respiratory diseases throughout the world. In the sovereign Navajo Nation, an American Indian reservation located in the Four Corners area of the USA, people burn coal in their homes for heat. To explore whether/how indoor coal combustion might contribute to poor respiratory health of residents, this study examined respiratory health data, identified household risk factors such as fuel and stove type and use, analyzed samples of locally used coal, and measured and characterized fine particulate airborne matter inside selected homes. In twenty-five percent of homes surveyed coal was burned in stoves not designed for that fuel, and indoor air quality was frequently found to be of a level to raise concerns. The average winter 24-hour PM 2.5 concentration in 20 homes was 36.0  μ g/ m 3 . This is the first time that PM 2.5 has been quantified and characterized inside Navajo reservation residents' homes.« less

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    M. Hoeschele, E. Weitzel

    Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16-month period were then used to validate a TRNSYS simulation model. The TRNSYSmore » model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.« less

Top