Evaluation of the Long-Term Stability and Temperature Coefficient of Dew-Point Hygrometers
NASA Astrophysics Data System (ADS)
Benyon, R.; Vicente, T.; Hernández, P.; De Rivas, L.; Conde, F.
2012-09-01
The continuous quest for improved specifications of optical dew-point hygrometers has raised customer expectations on the performance of these devices. In the absence of a long calibration history, users with a limited prior experience in the measurement of humidity, place reliance on manufacturer specifications to estimate long-term stability. While this might be reasonable in the case of measurement of electrical quantities, in humidity it can lead to optimistic estimations of uncertainty. This article reports a study of the long-term stability of some hygrometers and the analysis of their performance as monitored through regular calibration. The results of the investigations provide some typical, realistic uncertainties associated with the long-term stability of instruments used in calibration and testing laboratories. Together, these uncertainties can help in establishing initial contributions in uncertainty budgets, as well as in setting the minimum calibration requirements, based on the evaluation of dominant influence quantities.
A study to assess the long-term stability of the ionization chamber reference system in the LNMRI
NASA Astrophysics Data System (ADS)
Trindade Filho, O. L.; Conceição, D. A.; da Silva, C. J.; Delgado, J. U.; de Oliveira, A. E.; Iwahara, A.; Tauhata, L.
2018-03-01
Ionization chambers are used as secondary standard in order to maintain the calibration factors of radionuclides in the activity measurements in metrology laboratories. Used as radionuclide calibrator in nuclear medicine clinics to control dose in patients, its long-term performance is not evaluated systematically. A methodology for long-term evaluation for its stability is monitored and checked. Historical data produced monthly of 2012 until 2017, by an ionization chamber, electrometer and 226Ra, were analyzed via control chart, aiming to follow the long-term performance. Monitoring systematic errors were consistent within the limits of control, demonstrating the quality of measurements in compliance with ISO17025.
Optimization of scintillator loading with the tellurium-130 isotope for long-term stability
NASA Astrophysics Data System (ADS)
Duhamel, Lauren; Song, Xiaoya; Goutnik, Michael; Kaptanoglu, Tanner; Klein, Joshua; SNO+ Collaboration
2017-09-01
Tellurium-130 was selected as the isotope for the SNO + neutrinoless double beta decay search, as 130Te decays to 130Xe via double beta decay. Linear alkyl benzene(LAB) is the liquid scintillator for the SNO + experiment. To load tellurium into scintillator, it is combined with 1,2-butanediol to form an organometallic complex, commonly called tellurium butanediol (TeBD). This study focuses on maximizing the percentage of tellurium loaded into scintillator and evaluates the complex's long-term stability. Studies on the effect of nucleation due to imperfections in the detector's surface and external particulates were employed by filtration and induced nucleation. The impact of water on the stability of TeBD complex was evaluated by liquid-nitrogen sparging, variability in pH and induced humidity. Alternative loading methods were evaluated, including the addition of stability-inducing organic compounds. Samples of tellurium-loaded scintillator were synthesized, treated, and consistently monitored in a controlled environment. It was found that the hydronium ions cause precipitation in the loaded scintillator, demonstrating that water has a detrimental effect on long-term stability. Optimization of loaded scintillator stability can contribute to the SNO + double beta decay search.
Related Studies in Long Term Lithium Battery Stability
NASA Technical Reports Server (NTRS)
Horning, R. J.; Chua, D. L.
1984-01-01
The continuing growth of the use of lithium electrochemical systems in a wide variety of both military and industrial applications is primarily a result of the significant benefits associated with the technology such as high energy density, wide temperature operation and long term stability. The stability or long term storage capability of a battery is a function of several factors, each important to the overall storage life and, therefore, each potentially a problem area if not addressed during the design, development and evaluation phases of the product cycle. Design (e.g., reserve vs active), inherent material thermal stability, material compatibility and self-discharge characteristics are examples of factors key to the storability of a power source.
Long-term effect of lime-fly ash treated soils.
DOT National Transportation Integrated Search
2003-12-01
In October of 2000 MDOT initiated State Study No. 147, entitled "Long-Term Effect of Lime-Fly Ash Treated Soils." The purpose of this study : was to evaluate the long-term performance of LFA stabilized soil as a base course material. Part of the impe...
Frequency stability of maser oscillators operated with cavity Q. [hydrogen and rubidium masers
NASA Technical Reports Server (NTRS)
Tetu, M.; Tremblay, P.; Lesage, P.; Petit, P.; Audoin, C.
1982-01-01
The short term frequency stability of masers equipped with an external feedback loop to increase the cavity quality factor was studied. The frequency stability of a hydrogen and a rubidium maser were measured and compared with theoretical evaluation. It is shown that the frequency stability passes through an optimum when the cavity Q is varied. Long term fluctuations are discussed and the optimum mid term frequency stability achievably by small size active and passive H-masers is considered.
Muselík, Jan; Wojnarová, Lenka; Masteiková, Ruta; Sopuch, Tomáš
2013-04-01
Carboxymethyl cellulose, especially its sodium salt, is a versatile pharmaceutical excipient. From a therapeutic point of view, sodium salt of carboxymethyl cellulose is used in the production of modern wound dressings to allow moist wound healing. Wound dressings must be sterile and stable throughout their shelf life and have to be able to withstand different temperature conditions. At the present time, a number of sterilization methods are available. In the case of polymeric materials, the selected sterilization process must not induce any changes in the polymer structure, such as polymer chains cleavage, changes in cross-linking, etc. This paper evaluates the influence of different sterilization methods (γ-radiation, β-radiation, ethylene oxide) on the stability of carboxymethyl cellulose and the results of long-term and accelerated stability testing. Evaluation of samples was performed using size-exclusion chromatography. The obtained results showed that ethylene oxide sterilization was the least aggressive variant of the sterilization methods tested. When the γ-radiation sterilization was used, the changes in the size of the carboxymethyl cellulose molecule occurred. In the course of accelerated and long term stability studies, no further degradation changes were observed, and thus sterilized samples are suitable for long term storage.
Application of long-term simulation programs for analysis of system islanding
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sancha, J.L.; Llorens, M.L.; Moreno, J.M.
1997-02-01
This paper describes the main results and conclusions from the application of two different long-term stability programs to the analysis of a system islanding scenario for a study case developed by Red Electrica de Espana (REE), based on the Spanish system. Two main goals were to evaluate the performance of both the influence of some important control and protection elements (tie-line loss-of-synchronism relays, underfrequency load-shedding, load-frequency control, and power plant dynamics). Conclusions about modeling and computational requirements for system islanding (frequency) scenarios and use of long-term stability programs are presented.
NASA Astrophysics Data System (ADS)
Sharma, Asha; Rieth, Loren; Tathireddy, Prashant; Harrison, Reid; Solzbacher, Florian
2010-02-01
We herein report in vitro functional stability and recording longevity of a fully integrated wireless neural interface (INI). The INI uses biocompatible Parylene-C as an encapsulation layer, and was immersed in phosphate buffered saline (PBS) for a period of over 150 days. The full functionality (wireless radio-frequency power, command, and signal transmission) and the ability of INI to record artificial action potentials even after 150 days of PBS soaking without any change in signal/noise amplitude constitutes a major milestone in long term stability, and evaluate the encapsulation reliability, functional stability, and potential usefulness for future chronic implants.
Long-term stable active mount for reflective optics
NASA Astrophysics Data System (ADS)
Reinlein, C.; Brady, A.; Damm, C.; Mohaupt, M.; Kamm, A.; Lange, N.; Goy, M.
2016-07-01
We report on the development of an active mount with an orthogonal actuator matrix offering a stable shape optimization for gratings or mirrors. We introduce the actuator distribution and calculate the accessible Zernike polynomials from their actuator influence function. Experimental tests show the capability of the device to compensate for aberrations of grating substrates as we report measurements of a 110x105 mm2 and 220x210 mm2 device With these devices, we evaluate the position depending aberrations, long-term stability shape results, and temperature-induced shape variations. Therewith we will discuss potential applications in space telescopes and Earth-based facilities where long-term stability is mandatory.
USDA-ARS?s Scientific Manuscript database
Thermal energy storage (TES) systems incorporated with phase change materials (PCMs) have potential applications to control energy use by building envelopes. However, it is essential to evaluate long term performance of the PCMs and cost effectiveness prior to full scale implementation. For this rea...
Darshan, S Vinay; Ronad, Yusuf Ahammed; Kishore, M S V; Shetty, K Sadashiva; Rajesh, M; Suman, S D
2014-01-01
Background: The aim was to evaluate the long-term hard and soft tissue changes following mandibular advancement and setback surgeries. Materials and Methods: A total of 16 subjects each were selected who underwent bilateral sagittal split osteotomy mandibular advancement and mandibular setback groups. Pre-surgical (T1), immediate post-surgical (T2) and long-term post-surgical (T3) cephalograms were compared for hard and soft tissue changes. After cephalometric measurements, the quantity of changes between T1-T2 and T1-T3 were determined for each patient. The mean difference between T1-T2 and T1-T3 was compared with assess the long-term changes and stability. Results: In mandibular advancement the mean difference between immediate post-surgical and long term post-surgical is 7%, which accounts for a relapse of 7%. In mandibular setback, the mean difference between immediate post-surgical and long-term post-surgical is 29%, which accounts for a relapse of 29%. Conclusion: Mandibular advancement remained stable over the long period when compared to mandibular setback. PMID:25395792
Darshan, S Vinay; Ronad, Yusuf Ahammed; Kishore, M S V; Shetty, K Sadashiva; Rajesh, M; Suman, S D
2014-09-01
The aim was to evaluate the long-term hard and soft tissue changes following mandibular advancement and setback surgeries. A total of 16 subjects each were selected who underwent bilateral sagittal split osteotomy mandibular advancement and mandibular setback groups. Pre-surgical (T1), immediate post-surgical (T2) and long-term post-surgical (T3) cephalograms were compared for hard and soft tissue changes. After cephalometric measurements, the quantity of changes between T1-T2 and T1-T3 were determined for each patient. The mean difference between T1-T2 and T1-T3 was compared with assess the long-term changes and stability. In mandibular advancement the mean difference between immediate post-surgical and long term post-surgical is 7%, which accounts for a relapse of 7%. In mandibular setback, the mean difference between immediate post-surgical and long-term post-surgical is 29%, which accounts for a relapse of 29%. Mandibular advancement remained stable over the long period when compared to mandibular setback.
Development of a High-Stability Microstrip-based L-band Radiometer for Ocean Salinity Measurements
NASA Technical Reports Server (NTRS)
Pellerano, Fernando A.; Horgan, Kevin A.; Wilson, William J.; Tanner, Alan B.
2004-01-01
The development of a microstrip-based L-band Dicke radiometer with the long-term stability required for future ocean salinity measurements to an accuracy of 0.1 psu is presented. This measurement requires the L-band radiometers to have calibration stabilities of less than or equal to 0.05 K over 2 days. This research has focused on determining the optimum radiometer requirements and configuration to achieve this objective. System configuration and component performance have been evaluated with radiometer test beds at both JPL and GSFC. The GSFC testbed uses a cryogenic chamber that allows long-term characterization at radiometric temperatures in the range of 70 - 120 K. The research has addressed several areas including component characterization as a function of temperature and DC bias, system linearity, optimum noise diode injection calibration, and precision temperature control of components. A breadboard radiometer, utilizing microstrip-based technologies, has been built to demonstrate this long-term stability.
Angal, A.; Xiong, X.; Choi, T.; Chander, G.; Wu, A.
2009-01-01
Pseudo-invariant ground targets have been extensively used to monitor the long-term radiometric calibration stability of remote sensing instruments. The NASA MODIS Characterization Support Team (MCST), in collaboration with members from the U.S. Geological Survey (USGS) Earth Resources Observation and Science (EROS) Center, has previously demonstrated the use of pseudo-invariant ground sites for the long-term stability monitoring of Terra MODIS and Landsat 7 ETM+ sensors. This paper focuses on the results derived from observations made over the Sonoran Desert. Additionally, Landsat 5 TM data over the Sonoran Desert site were used to evaluate the temporal stability of this site. Top-ofatmosphere (TOA) reflectances were computed for the closely matched TM, ETM+, and MODIS spectral bands over selected regions of interest. The impacts due to different viewing geometries, or the effect of test site Bi-directional Reflectance Distribution Function (BRDF), are also presented. ?? 2009 SPIE.
Long-term maintenance of the carrier-envelope phase coherence of a femtosecond laser.
Kim, Eok Bong; Lee, Jae-Hwan; Lee, Won-Kyu; Luu, Tran Trung; Nam, Chang Hee
2010-12-06
The long-term carrier-envelope phase (CEP) coherence of a femtosecond laser with same pulse-to-pulse CEP value, obtained using the direct locking method, is demonstrated by employing a quasi-common-path interferometer (QPI). For the evaluation of the CEP stability, the phase noise properties of a femtosecond laser with the CEP stabilized using a QPI are compared with those obtained using a Mach-Zehnder f-2f interferometer, for which the phase power spectral density and the Allan deviation were calculated from the beat signals of the interferometers. With the improved CEP stability, the long-term CEP coherent signal with an accumulated phase noise well below 1 radian can be maintained for more than 56 hours, i.e., the CEP coherence is preserved without a phase cycle slip for more than 1.6 × 10(13) pulses at a repetition rate of 80 MHz. The relative stability is also estimated to be approximately 1.4 × 10(-22) at a central wavelength of 790 nm.
Ganaja, Kirsten A; Chaplan, Cory A; Zhang, Jingyi; Martinez, Nathaniel W; Martinez, Andres W
2017-05-16
Paper microzone plates in combination with a noncontact liquid handling robot were demonstrated as tools for studying the stability of enzymes stored on paper. The effect of trehalose and SU-8 epoxy novolac resin (SU-8) on the stability of horseradish peroxidase (HRP) was studied in both a short-term experiment, where the activity of various concentrations of HRP dried on paper were measured after 1 h, and a long-term experiment, where the activity of a single concentration of HRP dried and stored on paper was monitored for 61 days. SU-8 was found to stabilize HRP up to 35 times more than trehalose in the short-term experiment for comparable concentrations of the two reagents, and a 1% SU-8 solution was found to stabilize HRP approximately 2 times more than a 34% trehalose solution in both short- and long-term experiments. The results suggest that SU-8 is a promising candidate for use as an enzyme-stabilizing reagent for paper-based diagnostic devices and that the short-term experiment could be used to quickly evaluate the capacity of various reagents for stabilizing enzymes to identify and characterize new enzyme-stabilizing reagents.
Cortese, Antonio; Savastano, Mauro; Savastano, Germano; Claudio, Pier Paolo
2011-09-01
Transversal maxillary hypoplasia in adolescence is a frequently seen pathology, which can be treated with a combination of surgery and orthodontic treatment to widen the maxilla in skeletally matured patients.We evaluated the advantages of a new surgical technique: Le Fort I distraction osteogenesis using a bone-borne device. Because relapse is one of the main problems in surgical maxillary expansion, long-term stability of this new technique was evaluated. Data from 4 adult patients with maxillary restriction, class III malocclusion, or maxillary malposition were collected preoperatively, 4 months after distraction, and 5 years after distraction. Measurements were recorded on dental models to detect palatal expansion at dental level; cephalograms by lateral and posteroanterior plane were analyzed to detect maxillary movements. Maxillary measurements were substantially stable 5 years after distractions. Only minor dental movements occurred at the dental analysis after 5 years related to a lack of orthodontic contention without any compromise of the dental result (no crossbite relapse and class I stability). Le Fort I with down-fracture for expansion and repositioning by bone-borne distractor device can [corrected] be used to simultaneously widen, advance, and vertically reposition the maxilla without causing healing problems, particularly using a rigid distraction device. Long-term stability can be achieved; however, further studies with a larger number of patients will be necessary for better evaluation.
Long-Term Stability of Tutor Performance.
ERIC Educational Resources Information Center
Dolmans, Diana H. J. M.; And Others
1996-01-01
Examined the extent to which tutor ratings remained stable in the long term by evaluating 291 ratings of 140 tutors at Maastricht University in the Netherlands between 1992 and 1995. The results indicated that, if the aggregated score and overall judgement are used to interpret the precision of individual scores, four and two occasions,…
Long-Term Stability of Spaceflight Food for Multi-Year Exploration Missions
NASA Astrophysics Data System (ADS)
Douglas, G. L.; Barr, Y. R.
2018-02-01
Stability of macro- and micro-nutrients and undesirable changes to texture and taste will be evaluated in food samples returned from the Deep Space Gateway after 1, 3, and 5 years of storage in the deep space radiation environment.
USDA-ARS?s Scientific Manuscript database
Long-term tillage and cropping may influence biological attributes responsible for semi-arid soil aggregation in Montana, USA. Aggregate stability, glomalin, basidiomycete fungi, uronic acids, total organic C (TOC) and total N (TN) at 0-5 cm soil depth from 1991 to 2003 were evaluated in different a...
Stressed Stability Techniques for Adjuvant Formulations.
Hasija, Manvi; Sheung, Anthony; Rahman, Nausheen; Ausar, Salvador F
2017-01-01
Stressed stability testing is crucial to the understanding of mechanisms of degradation and the effects of external stress factors on adjuvant stability. These studies vastly help the development of stability indicating tests and the selection of stabilizing conditions for long term storage. In this chapter, we provide detailed protocols for the execution of forced degradation experiments that evaluate the robustness of adjuvant formulations against thermal, mechanical, freeze-thawing, and photo stresses.
Fernández, L; Scher, H; VanderGheynst, J S
2015-12-01
Prior research has demonstrated that microalgae can be stored for extended periods of time at room temperature in water-in-oil (W/O) emulsions stabilized by surface modified silica nanoparticles. However, little research has been done to examine the impact of nanoparticle concentration on emulsion stability. Such information is important for large-scale production of emulsions for microalgae storage and delivery. Studies were done to examine the impact of silica nanoparticle concentration on emulsion stability and identify the lower limit for nanoparticle concentration. Emulsion physical stability was determined using internal phase droplet size measurements and biological stability was evaluated using cell density measurements. The results demonstrate that nanoparticle concentrations as low as 0·5wt% in the oil phase can be used without significant losses in emulsion stability and microalgae viability. Stabilization technologies are needed for long-term storage and application of microalgae in agricultural-scale systems. While prior work has demonstrated that water-in-oil emulsions containing silica nanoparticles offer a promising solution for long-term microalgae storage at room temperature, little research has been done to examine the impact of nanoparticle concentration on emulsion stability. Here, we show the effects of silica nanoparticle concentration on maintaining physical stability of emulsions and sustaining viable cells. The results enable informed decisions to be made regarding production of emulsions containing silica nanoparticles and associated impacts on stabilization of microalgae. © 2015 The Society for Applied Microbiology.
The stability of the international oil trade network from short-term and long-term perspectives
NASA Astrophysics Data System (ADS)
Sun, Qingru; Gao, Xiangyun; Zhong, Weiqiong; Liu, Nairong
2017-09-01
To examine the stability of the international oil trade network and explore the influence of countries and trade relationships on the trade stability, we construct weighted and unweighted international oil trade networks based on complex network theory using oil trading data between countries from 1996 to 2014. We analyze the stability of international oil trade network (IOTN) from short-term and long-term aspects. From the short-term perspective, we find that the trade volumes play an important role on the stability. Moreover, the weighted IOTN is stable; however, the unweighted networks can better reflect the actual evolution of IOTN. From the long-term perspective, we identify trade relationships that are maintained during the whole sample period to reveal the situation of the whole international oil trade. We provide a way to quantitatively measure the stability of complex network from short-term and long-term perspectives, which can be applied to measure and analyze trade stability of other goods or services.
Development and evaluation of endurance test system for ventricular assist devices.
Sumikura, Hirohito; Homma, Akihiko; Ohnuma, Kentaro; Taenaka, Yoshiyuki; Takewa, Yoshiaki; Mukaibayashi, Hiroshi; Katano, Kazuo; Tatsumi, Eisuke
2013-06-01
We developed a novel endurance test system that can arbitrarily set various circulatory conditions and has durability and stability for long-term continuous evaluation of ventricular assist devices (VADs), and we evaluated its fundamental performance and prolonged durability and stability. The circulation circuit of the present endurance test system consisted of a pulsatile pump with a small closed chamber (SCC), a closed chamber, a reservoir and an electromagnetic proportional valve. Two duckbill valves were mounted in the inlet and outlet of the pulsatile pump. The features of the circulation circuit are as follows: (1) the components of the circulation circuit consist of optimized industrial devices, giving durability; (2) the pulsatile pump can change the heart rate and stroke length (SL), as well as its compliance using the SCC. Therefore, the endurance test system can quantitatively reproduce various circulatory conditions. The range of reproducible circulatory conditions in the endurance test circuit was examined in terms of fundamental performance. Additionally, continuous operation for 6 months was performed in order to evaluate the durability and stability. The circulation circuit was able to set up a wide range of pressure and total flow conditions using the SCC and adjusting the pulsatile pump SL. The long-term continuous operation test demonstrated that stable, continuous operation for 6 months was possible without leakage or industrial device failure. The newly developed endurance test system demonstrated a wide range of reproducible circulatory conditions, durability and stability, and is a promising approach for evaluating the basic characteristics of VADs.
Zi, Fei; Wu, Xuejian; Zhong, Weicheng; Parker, Richard H; Yu, Chenghui; Budker, Simon; Lu, Xuanhui; Müller, Holger
2017-04-01
We present a hybrid laser frequency stabilization method combining modulation transfer spectroscopy (MTS) and frequency modulation spectroscopy (FMS) for the cesium D2 transition. In a typical pump-probe setup, the error signal is a combination of the DC-coupled MTS error signal and the AC-coupled FMS error signal. This combines the long-term stability of the former with the high signal-to-noise ratio of the latter. In addition, we enhance the long-term frequency stability with laser intensity stabilization. By measuring the frequency difference between two independent hybrid spectroscopies, we investigate the short-and long-term stability. We find a long-term stability of 7.8 kHz characterized by a standard deviation of the beating frequency drift over the course of 10 h and a short-term stability of 1.9 kHz characterized by an Allan deviation of that at 2 s of integration time.
The Glyphosate-Based Herbicide Roundup Does not Elevate Genome-Wide Mutagenesis of Escherichia coli.
Tincher, Clayton; Long, Hongan; Behringer, Megan; Walker, Noah; Lynch, Michael
2017-10-05
Mutations induced by pollutants may promote pathogen evolution, for example by accelerating mutations conferring antibiotic resistance. Generally, evaluating the genome-wide mutagenic effects of long-term sublethal pollutant exposure at single-nucleotide resolution is extremely difficult. To overcome this technical barrier, we use the mutation accumulation/whole-genome sequencing (MA/WGS) method as a mutagenicity test, to quantitatively evaluate genome-wide mutagenesis of Escherichia coli after long-term exposure to a wide gradient of the glyphosate-based herbicide (GBH) Roundup Concentrate Plus. The genome-wide mutation rate decreases as GBH concentration increases, suggesting that even long-term GBH exposure does not compromise the genome stability of bacteria. Copyright © 2017 Tincher et al.
Polymer Latex Stability Modification by Exposure to Hydrophobic Solvents.
de Oliveira Cardoso A; Galembeck
1998-08-01
The stability of latex particles toward coagulation in the presence of salt is modified by swelling the latex with toluene and chloroform vapors. Short-term stability was determined by turbidimetric titrations, and the long-term stability was evaluated by adding latex and salt solutions, allowing the mixture to age for 24 or 48 h and determining the characteristics of the supernatant and of the sediment. Nine different latexes were examined, with variable results: in some cases, both apolar solvents stabilize the latex; in other cases, increased stability is induced by only one of the solvents, either toluene or chloroform. There is also coherence, but not a strict correlation, between the solvent effects on short- and long-term stability. For instance, in the case of a core-and-shell styrene-butyl methacrylate latex, chloroform has a small stabilizing effect in the titration experiment, but it prevents the formation of a coagulated latex sediment even 48 h after mixing latex and salt. Two hypotheses are discussed to account for these observations: (i) swelling solvents decrease the particles ability to dissipate the collision kinetic energy, so that particles collide but without joining each other; (ii) the solvents induce the release of trapped charged groups from the particle interior to the interface, enhancing the usual (electrostatic, steric, hydration) stability factors. Copyright 1998 Academic Press.
Ercikdi, Bayram; Baki, Hakan; İzki, Muhammet
2013-01-30
This paper presents the effect of desliming on the short- and long-term strength, stability and rheological properties of cemented paste backfill (CPB) produced from two different mill tailings. A 28-day unconfined compressive strength (UCS) of ≥1.0 MPa and the maintenance of stability over 224 days of curing were selected as the design criteria for the evaluation of paste backfill performance. Desliming induced some changes in the physical, chemical, mineralogical and rheological properties of the tailings. CPB mixture of the deslimed tailings achieved the required consistency at a lower water to cement ratio. The short-term UCSs of CPB samples of the deslimed tailings were found to be 30-100% higher than those samples of the reference tailings at all the binder dosages and curing times. CPB samples of the deslimed tailings achieved the long-term stability at relatively low binder dosages (e.g. 5 wt% c.f. ≥6.1% for the reference tailings). It was also estimated that desliming could allow a 13.4-23.1% reduction in the binder consumption depending apparently on the inherent characteristics of the tailings. Over the curing period, generation of sulphate and acid by the oxidation of pyrite present in the tailings was also monitored to correlate with the strength losses observed in the long term. Scanning electron microscope (SEM) and Mercury Intrusion Porosimetry (MIP) analyses provided an insight into the microstructure of CPB and the formation of secondary mineral phases (i.e. gypsum) confirming the beneficial effect of desliming. These findings suggest that desliming can be suitably exploited for CPB of sulphide-rich mill tailings to improve the strength and stability particularly in the long term and to reduce binder consumption. Copyright © 2012 Elsevier Ltd. All rights reserved.
Reduced Kalman Filters for Clock Ensembles
NASA Technical Reports Server (NTRS)
Greenhall, Charles A.
2011-01-01
This paper summarizes the author's work ontimescales based on Kalman filters that act upon the clock comparisons. The natural Kalman timescale algorithm tends to optimize long-term timescale stability at the expense of short-term stability. By subjecting each post-measurement error covariance matrix to a non-transparent reduction operation, one obtains corrected clocks with improved short-term stability and little sacrifice of long-term stability.
Zhang, Quan; Chen, Zheng; Chen, Shenghuo; Xu, Youyun; Deng, Huihua
2017-02-01
Cortisol, cortisone and the ratio of cortisol to cortisone in saliva, urine and hair are acute, short-term and long-term biomarkers to reliably assess the activity of hypothalamic-pituitary-adrenal (HPA) axis and 11β-hydroxysteroid dehydrogenase (11β-HSD). One key issue is whether these biomarkers have intraindividual relative stability. Salivary, urinary and hair cortisol was proven to show considerable long-term intraindividual relative stability. However, currently unknown is whether cortisone and the ratio in saliva, urine and hair show intraindividual relative stability. The present study utilized a longitudinal design to validate long-term stability within two weeks of three biomarkers in saliva and urine, and long-term stability within twelve months of three hair biomarkers. Salivary, urinary and hair steroids were measured with high performance liquid chromatography tandem mass spectrometry. Three biomarkers in urine and hair showed moderate test-retest correlations with coefficient (r) ranging between 0.22 and 0.56 and good multiple-test consistencies with coefficient of intraclass correlation (ICC) ranging between 0.42 and 0.67. Three single-point salivary biomarkers showed weak to moderate test-retest correlations (r's between 0.01 and 0.38) and poor to fair multiple-test consistencies (ICC's between 0.29 and 0.53) within two weeks. Three single-day salivary biomarkers showed moderate test-retest correlations (r's between 0.23 and 0.53) and good multiple-test consistencies (ICC's between 0.56 and 0.66) within two weeks. Three biomarkers in urine and hair showed moderate long-term intraindividual relative stability. Three single-point salivary biomarkers showed weak to moderate short-term and long-term intraindividual relative stability, but three single-day salivary biomarkers showed moderate short-term and long-term intraindividual relative stability. Copyright © 2016 Elsevier Inc. All rights reserved.
Unprecedented long-term frequency stability with a microwave resonator oscillator.
Grop, Serge; Schafer, Wolfgang; Bourgeois, Pierre-Yves; Kersale, Yann; Oxborrow, Mark; Rubiola, Enrico; Giordano, Vincent
2011-08-01
This article reports on the long-term frequency stability characterization of a new type of cryogenic sapphire oscillator using an autonomous pulse-tube cryocooler as its cold source. This new design enables a relative frequency stability of better than 4.5 x 10(-15) over one day of integration. To the best of our knowledge, this represents the best long-term frequency stability ever obtained with a signal source based on a macroscopic resonator.
Jeong, Jinmo; Chou, Namsun; Kim, Sohee
2016-06-01
This study investigates the mechanical and long-term electrical properties of parylene-caulked polydimethylsiloxane (PDMS) as a substrate for implantable electrodes. The parylene-caulked PDMS is a structure where particles of parylene fill the porous surface of PDMS. This material is expected to have low water absorption and desirable mechanical properties such as flexibility and elasticity that are beneficial in many biomedical applications. To evaluate the mechanical property and electrical stability of parylene-caulked PDMS for potential in-vivo uses, tensile tests were conducted firstly, which results showed that the mechanical strength of parylene-caulked PDMS was comparable to that of native PDMS. Next, surface electrodes based on parylene-caulked PDMS were fabricated and their impedance was measured in phosphate-buffered saline (PBS) solution at 36.5 °C over seven months. The electrodes based on parylene-caulked PDMS exhibited the improved stability in impedance over time than native PDMS. Thus, with improved electrical stability in wet environment and preserved mechanical properties of PDMS, the electrodes based on parylene-caulked PDMS are expected to be suitable for long-term in-vivo applications.
NASA Astrophysics Data System (ADS)
Hirai, Akiko; Bitou, Youichi; Oike, Yoshiyuki
2018-06-01
The long-term stability of NEXCERA™ ceramics having a low coefficient of thermal expansion was evaluated over a period of eight years. Several gauge blocks of differing lengths were prepared, using two types of NEXCERA. Each gauge block was kept wrung to a platen and its absolute length was periodically measured by gauge block interferometer during the eight years. Relative uncertainties of measurement of changes in gauge block length were estimated as 4.1 × 10‑8 and 2.9 × 10‑8 for 200 mm and 800 mm gauge blocks, respectively. The experimental results show the trend of expansion and a relative change of less than 0.1 × 10‑6/year for every gauge block.
Long-Term Stability of Core Language Skill in Children with Contrasting Language Skills
ERIC Educational Resources Information Center
Bornstein, Marc H.; Hahn, Chun-Shin; Putnick, Diane L.
2016-01-01
This 4-wave longitudinal study evaluated stability of core language skill in 421 European American and African American children, half of whom were identified as low (n = 201) and half of whom were average-to-high (n = 220) in later language skill. Structural equation modeling supported loadings of multivariate age-appropriate multisource measures…
Hsu, Cheng-Teng; Hsiao, Hung-Chan; Fang, Mei-Yen; Zen, Jyh-Myng
2009-10-15
Disposable one shot usage blood glucose strips are routinely used in the diagnosis and management of diabetes mellitus and their performance can vary greatly. In this paper we critically evaluated the long-term stability of glucose strips made of barrel plating gold electrodes. Compared to other glucose biosensing platforms of vapor deposited palladium and screen printed carbon electrodes, the proposed glucose biosensor was found to show the best stability among the three biosensing platforms in thermal acceleration experiments at 40 degrees C for 6 months with an average bias of 3.4% at glucose concentrations of 5-20 mM. The precision test of this barrel plating gold glucose biosensor also showed the best performance (coefficients of variation in the range of 1.4-2.4%) in thermal acceleration experiments at 40 degrees C, 50 degrees C and 70 degrees C for 27 days. Error grid analysis revealed that all measurements fell in zone A and zone B. Regression analysis showed no significant difference between the proposed biosensor and the reference method at 99% confidence level. The amperometric glucose biosensor fabricated by inserting two barrel plating gold electrodes onto an injection-molding plastic base followed by immobilizing with a bio-reagent layer and membrane was very impressive with a long-term stability up to 2.5 years at 25 degrees C. Overall, these results indicated that the glucose oxidase/barrel plating gold biosensing platform is ideal for long-term accurate glycemic control.
Promoting Healthy Weight with "Stability Skills First": A Randomized Trial
ERIC Educational Resources Information Center
Kiernan, Michaela; Brown, Susan D.; Schoffman, Danielle E.; Lee, Katherine; King, Abby C.; Taylor, C. Barr; Schleicher, Nina C.; Perri, Michael G.
2013-01-01
Objective: Although behavioral weight-loss interventions produce short-term weight loss, long-term maintenance remains elusive. This randomized trial examined whether learning a novel set of "stability skills" before losing weight improved long-term weight management. Stability skills were designed to optimize individuals' current…
Radionuclide Incorporation and Long Term Performance of Apatite Waste Forms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Jianwei; Lian, Jie; Gao, Fei
2016-01-04
This project aims to combines state-of-the-art experimental and characterization techniques with atomistic simulations based on density functional theory (DFT) and molecular dynamics (MD) simulations. With an initial focus on long-lived I-129 and other radionuclides such as Cs, Sr in apatite structure, specific research objectives include the atomic scale understanding of: (1) incorporation behavior of the radionuclides and their effects on the crystal chemistry and phase stability; (2) stability and microstructure evolution of designed waste forms under coupled temperature and radiation environments; (3) incorporation and migration energetics of radionuclides and release behaviors as probed by DFT and molecular dynamics (MD) simulations;more » and (4) chemical durability as measured in dissolution experiments for long term performance evaluation and model validation.« less
Van Hamersveld, Koen T; Marang-Van De Mheen, Perla J; Nelissen, Rob G H H; Toksvig-Larsen, Sören
2018-05-09
Background and purpose - Biological fixation of uncemented knee prostheses can be improved by applying hydroxyapatite coating around the porous surface via a solution deposition technique called Peri-Apatite (PA). The 2-year results of a randomized controlled trial, evaluating the effect of PA, revealed several components with continuous migration in the second postoperative year, particularly in the uncoated group. To evaluate whether absence of early stabilization is diagnostic of loosening, we now present long-term follow-up results. Patients and methods - 60 patients were randomized to PA-coated or uncoated (porous only) total knee arthroplasty of which 58 were evaluated with radiostereometric analysis (RSA) performed at baseline, at 3 months postoperatively and at 1, 2, 5, 7, and 10 years. A linear mixed-effects model was used to analyze the repeated measurements. Results - PA-coated components had a statistically significantly lower mean migration at 10 years of 0.94 mm (95% CI 0.72-1.2) compared with the uncoated group showing a mean migration of 1.72 mm (95% CI 1.4-2.1). Continuous migration in the second postoperative year was seen in 7 uncoated components and in 1 PA-coated component. All of these implants stabilized after 2 years except for 2 uncoated components. Interpretation - Peri-apatite enhances stabilization of uncemented components. The number of components that stabilized after 2 years emphasizes the importance of longer follow-up to determine full stabilization and risk of loosening in uncemented components with biphasic migration profiles.
FORMULATION AND STABILITY EVALUATION OF BAUHINIA VARIEGATA EXTRACT TOPICAL EMULSION.
Mohsin, Sabeeh; Akhtar, Naveed
2017-05-01
This study presents the results for the development of water in oil (W/O) emulsion containing 2 % Bauhinia variegata (BV) extract with good antioxidant potential for cosmetic application. Different ratios of surfactant, oil and water were investigated to optimize the ratio of ingredients. It was found that emulsifier and oil4ratio were important in improving the stability of emulsion. The formulation having 2.5% Abil EM90, 12% liquid paraffin, 83.5% distilled water and 2% BV extract was found to be most stable. Stability of the formulation was further evaluated by characterizing for organoleptic, sedimentation, microscopic and rheological properties at a range of storage conditions for a period of 12 weeks. Experimental findings showed stable formulation behavior with respect to color change, liquefaction and phase separation. Centrifugation test was carried out to predict the long term stability..The rheological parameters were evaluated from Power Law and the flow index value less than 1 suggested non-Newtonian behavior of the W/O emulsion. The mean droplet size of the internal phase of freshly prepared formulation was 4.06 ? 1.99 pm that did not change significantly (p > 0.05) during the storage. The newly developed formulation exhibited promising attributes over long term storage and open opportunities for the topical delivery of natural antioxidants for cosmetic and pharmaceutical objectives.
Le Tallec, David; Doucet, Diane; Elouahabi, Abdelatif; Harvengt, Pol; Deschuyteneer, Michel; Deschamps, Marguerite
2009-07-01
Cervarix is a recombinant human papillomavirus (HPV)-16 and -18 L1 virus-like-particle (VLP) AS04-adjuvanted vaccine designed to protect against cervical intraepithelial neoplasia and cervical cancer caused by the HPV types 16 and 18. Assessment of the stability of the vaccine during long-term storage and after transient exposure to temperatures out of normal storage range is an integrated part of vaccine quality evaluation. This assessment was done with vaccine samples stored at 2-8 degrees C for up to 36 months, with or without simulated cold chain break (either one week at 37 degrees C, or two or four weeks at 25 degrees C). Among the stability-indicating parameters, antigenicity and immunogenicity were evaluated along with L1 antigen integrity and adsorption to aluminum. Differential scanning calorimetry (DSC) was used to investigate the structural stability of the VLPs before and after vaccine formulation and over time. Cervarix was stable at 2-8 degrees C for at least three years, and the occurrence of cold chain break had no impact, as shown by unchanged product characteristics during the full storage period. DSC analysis demonstrated that the structure of the HPV-16 and -18 L1 proteins and their corresponding VLPs was not affected throughout the manufacturing process. Moreover, the structure of aluminum-adsorbed HPV-16 and -18 L1 VLPs was robust over a 14-month test period. In conclusion, Cervarix was very stable upon long-term storage at 2-8 degrees C with or without transient exposure to higher temperatures (up to 37 degrees C). The observed robust structure of the L1 VLPs contributes to the excellent stability of Cervarix.
Angal, Amit; Chander, Gyanesh; Xiong, Xiaoxiong; Choi, Tae-young; Wu, Aisheng
2011-01-01
To provide highly accurate quantitative measurements of the Earth's surface, a comprehensive calibration and validation of the satellite sensors is required. The NASA Moderate Resolution Imaging Spectroradiometer (MODIS) Characterization Support Team, in collaboration with United States Geological Survey, Earth Resources Observation and Science Center, has previously demonstrated the use of African desert sites to monitor the long-term calibration stability of Terra MODIS and Landsat 7 (L7) Enhanced Thematic Mapper plus (ETM+). The current study focuses on evaluating the suitability of the Sonoran Desert test site for post-launch long-term radiometric calibration as well as cross-calibration purposes. Due to the lack of historical and on-going in situ ground measurements, the Sonoran Desert is not usually used for absolute calibration. An in-depth evaluation (spatial, temporal, and spectral stability) of this site using well calibrated L7 ETM+ measurements and local climatology data has been performed. The Sonoran Desert site produced spatial variability of about 3 to 5% in the reflective solar regions, and the temporal variations of the site after correction for view-geometry impacts were generally around 3%. The results demonstrate that, barring the impacts due to occasional precipitation, the Sonoran Desert site can be effectively used for cross-calibration and long-term stability monitoring of satellite sensors, thus, providing a good test site in the western hemisphere.
Singh, Satinder Pal; Jena, Ashok Kumar; Rattan, Vidya; Utreja, Ashok Kumar
2012-01-01
Aim: To evaluate the treatment outcome and long-term stability of skeletal changes following maxillary advancement with distraction osteogenesis in adult subjects of cleft lip and palate. Materials and Methods: Total 12 North Indian adult patients in the age range of 17-34 years with cleft lip and palate underwent advancement of maxilla by distraction osteogenesis. Lateral cephalograms recorded prior to distraction, at the end of distraction, 6 months after distraction, and at least 24 months (mean 25.5 ± 1.94 months) after distraction osteogenesis were used for the evaluation of treatment outcome and long-term stability of the skeletal changes. Descriptive analysis, ANOVA, and post-hoc test were used, and P-value 0.05 was considered as a statistically significant level. Results: Maxillary distraction resulted in significant advancement of maxilla (P<0.001). Counterclockwise rotation of the palatal plane took place after maxillary distraction. The position of the mandible and facial heights were stable during distraction. During the first 6 months of the post-distraction period, the maxilla showed relapse of approximately 30%. However, after 6 months post distraction, the relapse was very negligible. Conclusions: Successful advancement of maxilla was achieved by distraction osteogenesis in adult subjects with cleft lip and palate. Most of the relapse occurred during the first 6 months of post-distraction period, and after that the outcomes were stable. PMID:22919221
Singh, Satinder Pal; Jena, Ashok Kumar; Rattan, Vidya; Utreja, Ashok Kumar
2012-04-01
To evaluate the treatment outcome and long-term stability of skeletal changes following maxillary advancement with distraction osteogenesis in adult subjects of cleft lip and palate. Total 12 North Indian adult patients in the age range of 17-34 years with cleft lip and palate underwent advancement of maxilla by distraction osteogenesis. Lateral cephalograms recorded prior to distraction, at the end of distraction, 6 months after distraction, and at least 24 months (mean 25.5 ± 1.94 months) after distraction osteogenesis were used for the evaluation of treatment outcome and long-term stability of the skeletal changes. Descriptive analysis, ANOVA, and post-hoc test were used, and P-value 0.05 was considered as a statistically significant level. Maxillary distraction resulted in significant advancement of maxilla (P<0.001). Counterclockwise rotation of the palatal plane took place after maxillary distraction. The position of the mandible and facial heights were stable during distraction. During the first 6 months of the post-distraction period, the maxilla showed relapse of approximately 30%. However, after 6 months post distraction, the relapse was very negligible. Successful advancement of maxilla was achieved by distraction osteogenesis in adult subjects with cleft lip and palate. Most of the relapse occurred during the first 6 months of post-distraction period, and after that the outcomes were stable.
Long term stability following genioplasty: a cephalometric study.
Kumar, B Lakshman; Raju, G Kranthi Praveen; Kumar, N Dilip; Reddy, G Vivek; Naik, B Ravindra; Achary, C Ravindranath
2015-04-01
A receding chin associated with an orthognathic mandible is a common situation and surgical changes in chin position are often required to improve the overall harmony of the face. Genioplasty is one such procedure. Stability of hard and soft tissue changes following genioplasty on a long term basis needs to be assessed. Studies on the stability of hard and soft tissue changes following genioplasty on a short term basis have revealed it as a procedure with good stability. This study is done to assess the stability of hard and soft tissue changes following genioplasty on a long term basis. Pre-surgical, postsurgical and long term post-surgical cephalograms of 15 cases treated by vertical reduction augmentation genioplasty were obtained. Paired t-test was used to compare the changes between pre-surgical, postsurgical and long term postsurgical cephalograms. Findings of this study demonstrated that genioplasty is a stable procedure. After long term follow-up period, there was a relapse of 1.5 mm at the pogonion accounting for 24% of the surgical advancement. This is attributed to the remodeling that occurs at the surgical site, but not the instability due to the surgical procedure. With the present study, it can be concluded that vertical reduction and advancement genioplasty can be considered as an adjunctive procedure that produces predictable results and the bony and soft tissue stability were generally very good.
Long Term Stability Following Genioplasty: A Cephalometric Study
Kumar, B Lakshman; Raju, G Kranthi Praveen; Kumar, N Dilip; Reddy, G Vivek; Naik, B Ravindra; Achary, C Ravindranath
2015-01-01
Background: A receding chin associated with an orthognathic mandible is a common situation and surgical changes in chin position are often required to improve the overall harmony of the face. Genioplasty is one such procedure. Stability of hard and soft tissue changes following genioplasty on a long term basis needs to be assessed. Studies on the stability of hard and soft tissue changes following genioplasty on a short term basis have revealed it as a procedure with good stability. This study is done to assess the stability of hard and soft tissue changes following genioplasty on a long term basis. Materials and Methods: Pre-surgical, postsurgical and long term post-surgical cephalograms of 15 cases treated by vertical reduction augmentation genioplasty were obtained. Paired t-test was used to compare the changes between pre-surgical, postsurgical and long term postsurgical cephalograms. Results: Findings of this study demonstrated that genioplasty is a stable procedure. After long term follow-up period, there was a relapse of 1.5 mm at the pogonion accounting for 24% of the surgical advancement. This is attributed to the remodeling that occurs at the surgical site, but not the instability due to the surgical procedure. Conclusion: With the present study, it can be concluded that vertical reduction and advancement genioplasty can be considered as an adjunctive procedure that produces predictable results and the bony and soft tissue stability were generally very good. PMID:25954070
Characterization of cementitiously stabilized subgrades for mechanistic-empirical pavement design
NASA Astrophysics Data System (ADS)
Solanki, Pranshoo
Pavements are vulnerable to subgrade layer performance because it acts as a foundation. Due to increase in the truck traffic, pavement engineers are challenged to build more strong and long-lasting pavements. To increase the load-bearing capacity of pavements, subgrade layer is often stabilized with cementitious additives. Thus, an overall characterization of stabilized subgrade layer is important for enhanced short- and long-term pavement performance. In this study, the effect of type and amount of additive on the short-term performance in terms of material properties recommended by the new Mechanistic-Empirical Pavement Design Guide (MEPDG) is examined. A total of four soils commonly encountered as subgrades in Oklahoma are utilized. Results show that the changes in the Mr, ME and UCS values stabilized specimens depend on the soil type and properties of additives. The long-term performance (or durability) of stabilized soil specimens is investigated by conducting freeze-thaw (F-T) cycling, vacuum saturation and tube suction tests on 7-day cured P-, K- and C-soil specimens stabilized with 6% lime, 10% CFA and 10% CKD. This study is motivated by the fact that during the service life of pavement stabilized layers are subjected to F-T cycles and moisture variations. It is found that that UCS value of all the stabilized specimens decreased with increase in the number of F-T cycles. A strong correlation was observed between UCS values retained after vacuum saturation and F-T cycles indicating that vacuum saturation could be used as a time-efficient and inexpensive method for evaluating durability of stabilized soils. In this study, short- and long-term observations from stabilization of sulfate bearing soil with locally available low (CFA), moderate (CKD) and high (lime) calcium-based stabilizers are determined to evaluate and compare the effect of additive type on the phenomenon of sulfate-induced heave. The impact of different factors on the development of the ettringite, responsible for sulfate-induced heaving, is also discussed. For Level 2 design of pavements, a total of four stress-based statistical models and two feed-forward-type artificial neural network (ANN) models, are evaluated for predicting resilient modulus of 28-day cured stabilized specimens. Specifically, one semi-log stress-based, three log-log stress-based, one Multi-Layer Perceptrons Network (MLPN), and one Radial Basis Function Network (RBFN) are developed. Overall, semi-log stress-based and MLPN neural network are found to show best acceptable performance for the present evaluation and validation datasets. Further, correlations are presented for stress-based models to correlate Mr with compacted specimen characteristics and soil/additive properties. Additionally, the effect of type of additive on indirect tensile and fatigue characteristics of selected stabilized P- and V-soil is evaluated. This study is based on the fact that stabilized layer is subjected to tensile stresses under wheel loading. Thus, the resilient modulus in tension (M rt), fatigue life and strength in tension (sigmat) or flexure (represented by modulus of rupture, MOR) becomes another important design parameter within the mechanistic framework. Cylindrical specimens are prepared, cured for 28 days and subjected to different stress sequences in indirect tension to study the Mrt. On the other hand, stabilized beam specimens are compacted using a Linear Kneading Compactor and subjected to repeated cycles of reloading-unloading after 28 days of curing in a four-point beam fatigue apparatus for evaluating fatigue life and flexural stiffness. It is found that all three additives improved the Mrt, sigmat and MOR values; however, degree of improvement varied with the type of additive and soil. This study encompasses the differences in the design of semi-rigid pavements developed using AASHTO 1993 and AASHTO 2002 MEPDG methodologies. Further, the design curves for fatigue performance prediction of stabilized layers are developed for different stabilized pavement sections. Knowledge gained from the parametric analysis of different sections using AASHTO 1993 and MEPDG is expected to be useful to pavement designers and others in implementation of the new MEPDG for future pavement design. (Abstract shortened by UMI.)
O'Donnell, Sean T; Caldwell, Michael D; Barlaz, Morton A; Morris, Jeremy W F
2018-05-01
Municipal solid waste (MSW) landfills in the USA are regulated under Subtitle D of the Resource Conservation and Recovery Act (RCRA), which includes the requirement to protect human health and the environment (HHE) during the post-closure care (PCC) period. Several approaches have been published for assessment of potential threats to HHE. These approaches can be broadly divided into organic stabilization, which establishes an inert waste mass as the ultimate objective, and functional stability, which considers long-term emissions in the context of minimizing threats to HHE in the absence of active controls. The objective of this research was to conduct a case study evaluation of a closed MSW landfill using long-term data on landfill gas (LFG) production, leachate quality, site geology, and solids decomposition. Evaluations based on both functional and organic stability criteria were compared. The results showed that longer periods of LFG and leachate management would be required using organic stability criteria relative to an approach based on functional stability. These findings highlight the somewhat arbitrary and overly stringent nature of assigning universal stability criteria without due consideration of the landfill's hydrogeologic setting and potential environmental receptors. This supports previous studies that advocated for transition to a passive or inactive control stage based on a performance-based functional stability framework as a defensible mechanism for optimizing and ending regulatory PCC. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Garland, J. L.; Cook, K. L.; Johnson, M.; Sumner, R.; Fields, N.; Sager, J. C. (Principal Investigator)
1997-01-01
A study evaluating alternative methods for long term operation of biomass production systems was recently completed at the Kennedy Space Center (KSC). The 418-day study evaluated repeated batch versus mixed-aged production of potato grown on either standard 1/2-strength Hoagland's nutrient solution or solutions including nutrients recycled from inedible plant material. The long term effects of closure and recycling on microbial dynamics were evaluated by monitoring the microbial communities associated with various habitats within the plant growth system (i.e., plant roots, nutrient solution, biofilms within the hydroponic systems, atmosphere, and atmospheric condensate). Plate count methods were used to enumerate and characterize microorganisms. Microscopic staining methods were used to estunate total cell densities. The primary finding was that the density and composition of microbial communities associated with controlled environmental plant growth systems are stable during long term operation. Continuous production resulted in slightly greater stability. Nutrient recycling, despite the addition of soluble organic material from the waste processing system, did not significantly increase microbial density in any of the habitats.
NASA Astrophysics Data System (ADS)
Garland, J. L.; Cook, K. L.; Johnson, M.; Sumner, R.; Fields, N.
1997-01-01
A study evaluating alternative methods for long term operation of biomass production systems was recently completed at the Kennedy Space Center (KSC). The 418-day study evaluated repeated batch versus mixed-aged production of potato grown on either standard 1/2-strength Hoagland's nutrient solution or solutions including nutrients recycled from inedible plant material. The long term effects of closure and recycling on microbial dynamics were evaluated by monitoring the microbial communities associated with various habitats within the plant growth system (i.e., plant roots, nutrient solution, biofilms within the hydroponic systems, atmosphere, and atmospheric condensate). Plate count methods were used to enumerate and characterize microorganisms. Microscopic staining methods were used to estimate total cell densities. The primary finding was that the density and composition of microbial communities associated with controlled environmental plant growth systems are stable during long term operation. Continuous production resulted in slightly greater stability. Nutrient recycling, despite the addition of soluble organic material from the waste processing system, did not significantly increase microbial density in any of the habitats.
NASA Astrophysics Data System (ADS)
1997-01-01
A study evaluating alternative methods for long term operation of biomass production systems was recently completed at the Kennedy Space Center (KSC). The 418-day study evaluated repeated batch versus mixed-aged production of potato grown on either standard
Stability and predictors of change in salivary cortisol measures over six years: MESA.
Wang, Xu; Sánchez, Brisa N; Golden, Sherita Hill; Shrager, Sandi; Kirschbaum, Clemens; Karlamangla, Arun S; Seeman, Teresa E; Roux, Ana V Diez
2014-11-01
A major challenge in characterizing features of the daily cortisol curve is variability in features over time. Few studies have examined the stability of daily features of the cortisol curve over long periods or the predictors of long term changes. Repeated salivary cortisol measures on 580 adults from the MESA Stress study were used to examine the stability of various features of the daily cortisol curve (wakeup value, the cortisol awakening response (CAR), the early and late decline slope and the area under the curve (AUC)), over short periods (several days) and long periods (approximately 6-years) and to investigate the association of demographic factors with the changes. Intraclass correlation coefficients (ICCs) were used to estimate the short and long term stability. Piecewise linear mixed models were used to assess factors associated with changes in features over time. For most features, short term stability (ICCs: 0.17-0.74) was higher than long term stability (ICCs: 0.05-0.42), and long term stability was highest when several days were averaged for each time point. The decline over the day showed the highest long term stability: when several days for each wave were averaged the stability of the daily decline slope across 6 years was similar (or higher) than the stability across short periods. AUC had high stability over short periods (ICCs: 0.65-0.74) but much lower stability across long periods (ICC: 0.05). All features of daily cortisol curve investigated changed significantly over the approximately 6 year follow-up period. The wakeup cortisol became higher; the CAR became smaller; both the early and late decline became flatter; and the AUC became larger. Hispanics experienced significantly larger increases in the wakeup value; and African-Americans and Hispanics showed less flattening over time of the early decline slope than Non-Hispanic Whites. Our findings have implications for characterization of features in studies linking cortisol to health outcomes. The presence of variability over time suggests opportunities for future investigation of the predictors of changes over time as well as the links between these changes and health outcomes. Copyright © 2014 Elsevier Ltd. All rights reserved.
[Stabilization and long-term effect of chromium contaminated soil].
Wang, Jing; Luo, Qi-Shi; Zhang, Chang-Bo; Tan, Liang; Li, Xu
2013-10-01
Short-term (3 d and 28 d) and long-term (1 a) stabilization effects of Cr contaminated soil were investigated through nature curing, using four amendments including ferrous sulfide, ferrous sulfate, zero-valent iron and sodium dithionite. The results indicated that ferrous sulfide and zero-valent iron were not helpful for the stabilization of Cr(VI) when directly used because of their poor solubility and immobility. Ferrous sulfate could effectively and rapidly decrease total leaching Cr and Cr(VI) content. The stabilization effect was further promoted by the generation of iron hydroxides after long-term curing. Sodium dithionite also had positive effect on soil stabilization. Appropriate addition ratio of the two chemicals could help maintain the soil pH in range of 6-8.
Long-Term Stability of Oxide Nanowire Sensors via Heavily Doped Oxide Contact.
Zeng, Hao; Takahashi, Tsunaki; Kanai, Masaki; Zhang, Guozhu; He, Yong; Nagashima, Kazuki; Yanagida, Takeshi
2017-12-22
Long-term stability of a chemical sensor is an essential quality for long-term collection of data related to exhaled breath, environmental air, and other sources in the Internet of things (IoT) era. Although an oxide nanowire sensor has shown great potential as a chemical sensor, the long-term stability of sensitivity has not been realized yet due to electrical degradation under harsh sensing conditions. Here, we report a rational concept to accomplish long-term electrical stability of metal oxide nanowire sensors via introduction of a heavily doped metal oxide contact layer. Antimony-doped SnO 2 (ATO) contacts on SnO 2 nanowires show much more stable and lower electrical contact resistance than conventional Ti contacts for high temperature (200 °C) conditions, which are required to operate chemical sensors. The stable and low contact resistance of ATO was confirmed for at least 1960 h under 200 °C in open air. This heavily doped oxide contact enables us to realize the long-term stability of SnO 2 nanowire sensors while maintaining the sensitivity for both NO 2 gas and light (photo) detections. The applicability of our method is confirmed for sensors on a flexible polyethylene naphthalate (PEN) substrate. Since the proposed fundamental concept can be applied to various oxide nanostructures, it will give a foundation for designing long-term stable oxide nanomaterial-based IoT sensors.
Long-term surgical-orthodontic management of hemimandibular hyperplasia.
Bennett, Samuel C; Goonewardene, Mithran S
2016-05-01
Hemimandibular hyperplasia (HH), also known as hemimandibular hypertrophy, is characterised by excessive unilateral three-dimensional growth of the mandible after birth. Vertical unilateral elongation of the mandible becomes clinically evident as a rare form of vertical facial asymmetry. Aberrant growth of the facial skeleton affects the developing dentition and the dental compensatory mechanism is usually unable to maintain optimal occlusal relationships. The resulting malocclusion is effectively managed by combined surgical-orthodontic care to address the facial, skeletal and dental problems that confront clinicians. Orthodontists are advised to assess patients with HH during the post-treatment retention stage for continuing mandibular growth and assess the stability of treatment outcomes with long-term follow-up and records as required. To present a case of hemimandibular hyperplasia treated successfully by combined surgical-orthodontic care and evaluated for stability over a seven-year follow-up period. Surgical-orthodontic management was accomplished in four stages: 1) pre-surgical orthodontic; 21 surgical; 3) post-surgical orthodontic; and 4) post-treatment orthodontic retention. Complete orthodontic records, including extra- and intra-oral photographs, study models, and cephalograms plus panoramic radiographs were taken at the pretreatment, post-treatment, and seven-year orthodontic retention time-points. Facial, skeletal and dental goals were achieved in the three planes of space and the long-term stability of the treatment results was shown during a post-treatment orthodontic retention period of seven years. Hemimandibular hyperplasia is a true growth anomaly which may be managed effectively. Clinicians may expect successful long-term correction and stability by utilising a comprehensive surgical-orthodontic treatment approach.
Evaluating the Long-Term Stability of Metals Precipitated In-Situ
Because metals (including metals and metalloids) cannot be destroyed, unlike organic contaminants, in-situ approaches for their removal from groundwater necessarily involves fixation/immobilization in the solid aquifer matrix. Consequently, the success of precipitation based in...
Chemical stabilization of metals and arsenic in contaminated soils using oxides--a review.
Komárek, Michael; Vaněk, Aleš; Ettler, Vojtěch
2013-01-01
Oxides and their precursors have been extensively studied, either singly or in combination with other amendments promoting sorption, for in situ stabilization of metals and As in contaminated soils. This remediation option aims at reducing the available fraction of metal(loid)s, notably in the root zone, and thus lowering the risks associated with their leaching, ecotoxicity, plant uptake and human exposure. This review summarizes literature data on mechanisms involved in the immobilization process and presents results from laboratory and field experiments, including the subsequent influence on higher plants and aided phytostabilization. Despite the partial successes in the field, recent knowledge highlights the importance of long-term and large-scale field studies evaluating the stability of the oxide-based amendments in the treated soils and their efficiency in the long-term. Copyright © 2012 Elsevier Ltd. All rights reserved.
Vaccine stability study design and analysis to support product licensure.
Schofield, Timothy L
2009-11-01
Stability evaluation supporting vaccine licensure includes studies of bulk intermediates as well as final container product. Long-term and accelerated studies are performed to support shelf life and to determine release limits for the vaccine. Vaccine shelf life is best determined utilizing a formal statistical evaluation outlined in the ICH guidelines, while minimum release is calculated to help assure adequate potency through handling and storage of the vaccine. In addition to supporting release potency determination, accelerated stability studies may be used to support a strategy to recalculate product expiry after an unintended temperature excursion such as a cold storage unit failure or mishandling during transport. Appropriate statistical evaluation of vaccine stability data promotes strategic stability study design, in order to reduce the uncertainty associated with the determination of the degradation rate, and the associated risk to the customer.
NASA Technical Reports Server (NTRS)
Ohring, G.; Wielicki, B.; Spencer, R.; Emery, B.; Datla, R.
2004-01-01
Measuring the small changes associated with long-term global climate change from space is a daunting task. To address these problems and recommend directions for improvements in satellite instrument calibration some 75 scientists, including researchers who develop and analyze long-term data sets from satellites, experts in the field of satellite instrument calibration, and physicists working on state of the art calibration sources and standards met November 12 - 14, 2002 and discussed the issues. The workshop defined the absolute accuracies and long-term stabilities of global climate data sets that are needed to detect expected trends, translated these data set accuracies and stabilities to required satellite instrument accuracies and stabilities, and evaluated the ability of current observing systems to meet these requirements. The workshop's recommendations include a set of basic axioms or overarching principles that must guide high quality climate observations in general, and a roadmap for improving satellite instrument characterization, calibration, inter-calibration, and associated activities to meet the challenge of measuring global climate change. It is also recommended that a follow-up workshop be conducted to discuss implementation of the roadmap developed at this workshop.
Romanos, Georgios E
2009-06-01
Immediate loading of oral implants has been extensively described in the international literature and the requirements for long-term success are evaluated. The author presents here the critical aspects of the criteria for success as well as describes the characteristics of an implant macro- and microdesign for immediate loading to control the periimplant crestal bone loss and secure the long-term stability. Information from the literature and the clinical experience will be presented.
Stability of Beriplast P fibrin sealant: storage and reconstitution.
Eberhard, Ulrich; Broder, Martin; Witzke, Günther
2006-04-26
This study was performed to investigate the stability of Beriplast P fibrin sealant (FS) across a range of storage conditions, both pre- and post-reconstitution. Storage stability of the FS was evaluated during long-term refrigeration (24 months) with or without interim storage at elevated temperatures (40 degrees C for 1 week and 25 degrees C for 1 and 3 months). Stability of individual FS components was assessed by measuring: fibrinogen content, Factor XIII activity (FXIII), thrombin activity and aprotinin potency. The package integrity of each component was also checked (sterility testing, moisture content and pH). Storage stability was also evaluated by testing the reconstituted product for adhesion (tearing force testing after mixing the solutions) and sterility. Reconstitution stability was evaluated following 3-months' storage, for up to 50 h post-reconstitution using the same tests as for the storage stability investigations. Pre-defined specifications were met for fibrinogen content, Factor XIII activity, and thrombin activity, demonstrating storage stability. Package integrity and the functionality and sterility of the reconstituted product were confirmed throughout. Reconstitution stability was demonstrated for up to 50 h following reconstitution, in terms of both tearing force and sterility tests. In conclusion, the storage stability of Beriplast P was demonstrated over a range of 24-month storage schedules including interim exposure to elevated temperature, and the reconstituted product was stable for up to 50 h.
Treatment stability with the eruption guidance appliance.
Janson, Guilherme; Nakamura, Alexandre; Chiqueto, Kelly; Castro, Renata; de Freitas, Marcos Roberto; Henriques, José Fernando Castanha
2007-06-01
Although the eruption guidance appliance has been used to correct Class II malocclusions for many years and its effects have been demonstrated, there is no study on the stability of the changes it produces. Therefore, the objective of this study was to investigate the long-term stability of cephalometric dentoskeletal and occlusal changes after eruption guidance appliance therapy. Thirty-nine patients were evaluated. Occlusal evaluations were made with the peer asseessment rating index, and anterior tooth irregularity was evaluated with the Little irregularity index. Cephalometric and occlusal data were obtained at pretreatment, posttreatment, and postretention. The data were analyzed by dependent 1-way analysis of variance (ANOVA) for comparison between the 3 stages of the experimental group, with the Newman-Keuls test as a second step. To compare the cephalometric experimental group changes with mean population changes, the t test was used. Cephalometrically, in the postretention stage, overjet remained stable, overbite showed significant relapse, and molar relationship improved toward a Class I relationship. The peer asseessment rating index showed stability of the occlusion. The Little irregularity index demonstrated a statistically significant relapse of crowding in the postretention stage. Cephalometrically, overjet and molar relationship were stable in the long term after treatment with the eruption guidance appliance; however, there was relapse of the overbite. Occlusally, correction of the malocclusion elevated by the peer assessment rating was stable. There was relapse of the anterior teeth crowding.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelekis, A., E-mail: akelekis@med.uoa.gr; Filippiadis, D., E-mail: dfilippiadis@yahoo.gr; Anselmetti, G., E-mail: gc.anselmetti@fastwebnet.it
PurposeTo evaluate clinical efficacy/safety of augmented peripheral osteoplasty in oncologic patients with long-term follow-up.Materials and MethodsPercutaneous augmented peripheral osteoplasty was performed in 12 patients suffering from symptomatic lesions of long bones. Under extensive local sterility measures, anesthesiology care, and fluoroscopic guidance, direct access to lesion was obtained and coaxially a metallic mesh consisting of 25–50 medical grade stainless steel micro-needles (22 G, 2–6 cm length) was inserted. PMMA for vertebroplasty was finally injected under fluoroscopic control. CT assessed implant position 24-h post-treatment.ResultsClinical evaluation included immediate and delayed follow-up studies of patient’s general condition, NVS pain score, and neurological status. Imaging assessedmore » implant’s long-term stability. Mean follow-up was 16.17 ± 10.93 months (range 2–36 months). Comparing patients’ scores prior (8.33 ± 1.67 NVS units) and post (1.42 ± 1.62 NVS units) augmented peripheral osteoplasty, there was a mean decrease of 6.92 ± 1.51 NVS units. Overall mobility improved in 12/12 patients. No complication was observed.ConclusionPercutaneous augmented peripheral osteoplasty (rebar concept) for symptomatic malignant lesions in long bones seems to be a possible new technique for bone stabilization. This combination seems to provide necessary stability against shearing forces applied in long bones during weight bearing.« less
Accurate Determination of Soluble Axl by Enzyme-Linked Immunosorbent Assay.
Dengler, Mirko; Huber, Heidemarie; Müller, Christian J; Zellmer, Angela; Rauch, Peter; Mikulits, Wolfgang
2016-11-01
Levels of soluble Axl (sAxl) are routinely assessed in human sera by sandwich enzyme-linked immunosorbent assay (ELISA). Although sAxl values are suggested to diagnose different types of disorders, no uniform ELISA method is available, allowing the reliable interassay comparison between results. Furthermore, little is known about the stability of sAxl under storage conditions, which is a relevant parameter for biomedical trials. The evaluation of sAxl stability under various stress conditions and the determination of proper conditions to use the sAxl ELISA for routine clinical applications are of great interest. In this study, serum samples were subjected to freeze-thaw cycles and incubation at different temperatures to analyze the stability of sAxl by ELISA. Dilution and spike-in experiments were carried out to examine the impact of serum and diluent components on the ELISA performance. Various diluents and media were employed to resolve masking effects of the serum. The assay components were further optimized for long-term usability by treatment with stabilizers and validation under temperature stress. Indeed, sAxl showed long-term stability in serum during freeze-thaw cycles and incubation under temperature stress conditions. The dilution experiments revealed that unknown components in the serum caused masking effects that can be reduced by proper dilutions. The assay performance was further increased by using a standardized buffer system to dilute serum samples. Stabilization of coated plates and of streptavidin-horseradish peroxidase allowed long-term storage for up to 6 months. In sum, our data demonstrate proper ELISA conditions, allowing the accurate analysis of sAxl levels in human serum.
Creep Property Characterization of Potential Brayton Cycle Impeller and Duct Materials
NASA Astrophysics Data System (ADS)
Gabb, Timothy P.; Gayda, John; Garg, Anita
2007-01-01
Cast superalloys have potential applications in space as impellers within closed-loop Brayton cycle nuclear power generation systems. Likewise wrought superalloys are good candidates for ducts and heat exchangers transporting the inert working gas in a Brayton-based power plant. Two cast superalloys, Mar-M247LC and IN792, and a NASA GRC powder metallurgy superalloy, LSHR, have been screened to compare their respective capabilities for impeller applications. Mar-M247LC has been selected for additional long term evaluations. Initial tests in helium indicate this inert environment may debit long term creep resistance of this alloy. Several wrought superalloys including Hastelloy® X, Inconel® 617, Inconel® 740, Nimonic® 263, Incoloy® MA956, and Haynes 230 are also being screened to compare their capabilities for duct applications. Haynes 230 has been selected for additional long term evaluations. Initial tests in helium are just underway for this alloy. These proposed applications would require sufficient strength and creep resistance for long term service at temperatures up to 1200 K, with service times to 100,000 h or more. Therefore, long term microstructural stability is also being screened.
Creep Property Characterization of Potential Brayton Cycle Impeller and Duct Materials
NASA Technical Reports Server (NTRS)
Gabb, Timothy P.; Gayda, john; Garg, Anita
2007-01-01
Cast superalloys have potential applications in space as impellers within closed-loop Brayton cycle nuclear power generation systems. Likewise wrought superalloys are good candidates for ducts and heat exchangers transporting the inert working gas in a Brayton-based power plant. Two cast superalloys, Mar-M247LC and IN792, and a NASA GRC powder metallurgy superalloy, LSHR, have been screened to compare their respective capabilities for impeller applications. Mar-M247LC has been selected for additional long term evaluations. Initial tests in helium indicate this inert environment may debit long term creep resistance of this alloy. Several wrought superalloys including Hastelloy(Registered TradeMark) X, Inconel(Registered TradeMark) 617, Inconel(Registered TradeMark) 740, Nimonic(Registered TradeMark) 263, Incoloy(Registered TradeMark) MA956, and Haynes 230 are also being screened to compare their capabilities for duct applications. Haynes 230 has been selected for additional long term evaluations. Initial tests in helium are just underway for this alloy. These proposed applications would require sufficient strength and creep resistance for long term service at temperatures up to 1200 K, with service times to 100,000 h or more. Therefore, long term microstructural stability is also being screened.
Towards the 1 mm/y stability of the radial orbit error at regional scales
NASA Astrophysics Data System (ADS)
Couhert, Alexandre; Cerri, Luca; Legeais, Jean-François; Ablain, Michael; Zelensky, Nikita P.; Haines, Bruce J.; Lemoine, Frank G.; Bertiger, William I.; Desai, Shailen D.; Otten, Michiel
2015-01-01
An estimated orbit error budget for the Jason-1 and Jason-2 GDR-D solutions is constructed, using several measures of orbit error. The focus is on the long-term stability of the orbit time series for mean sea level applications on a regional scale. We discuss various issues related to the assessment of radial orbit error trends; in particular this study reviews orbit errors dependent on the tracking technique, with an aim to monitoring the long-term stability of all available tracking systems operating on Jason-1 and Jason-2 (GPS, DORIS, SLR). The reference frame accuracy and its effect on Jason orbit is assessed. We also examine the impact of analysis method on the inference of Geographically Correlated Errors as well as the significance of estimated radial orbit error trends versus the time span of the analysis. Thus a long-term error budget of the 10-year Jason-1 and Envisat GDR-D orbit time series is provided for two time scales: interannual and decadal. As the temporal variations of the geopotential remain one of the primary limitations in the Precision Orbit Determination modeling, the overall accuracy of the Jason-1 and Jason-2 GDR-D solutions is evaluated through comparison with external orbits based on different time-variable gravity models. This contribution is limited to an East-West “order-1” pattern at the 2 mm/y level (secular) and 4 mm level (seasonal), over the Jason-2 lifetime. The possibility of achieving sub-mm/y radial orbit stability over interannual and decadal periods at regional scales and the challenge of evaluating such an improvement using in situ independent data is discussed.
Towards the 1 mm/y Stability of the Radial Orbit Error at Regional Scales
NASA Technical Reports Server (NTRS)
Couhert, Alexandre; Cerri, Luca; Legeais, Jean-Francois; Ablain, Michael; Zelensky, Nikita P.; Haines, Bruce J.; Lemoine, Frank G.; Bertiger, William I.; Desai, Shailen D.; Otten, Michiel
2015-01-01
An estimated orbit error budget for the Jason-1 and Jason-2 GDR-D solutions is constructed, using several measures of orbit error. The focus is on the long-term stability of the orbit time series for mean sea level applications on a regional scale. We discuss various issues related to the assessment of radial orbit error trends; in particular this study reviews orbit errors dependent on the tracking technique, with an aim to monitoring the long-term stability of all available tracking systems operating on Jason-1 and Jason-2 (GPS, DORIS, SLR). The reference frame accuracy and its effect on Jason orbit is assessed. We also examine the impact of analysis method on the inference of Geographically Correlated Errors as well as the significance of estimated radial orbit error trends versus the time span of the analysis. Thus a long-term error budget of the 10-year Jason-1 and Envisat GDR-D orbit time series is provided for two time scales: interannual and decadal. As the temporal variations of the geopotential remain one of the primary limitations in the Precision Orbit Determination modeling, the overall accuracy of the Jason-1 and Jason-2 GDR-D solutions is evaluated through comparison with external orbits based on different time-variable gravity models. This contribution is limited to an East-West "order-1" pattern at the 2 mm/y level (secular) and 4 mm level (seasonal), over the Jason-2 lifetime. The possibility of achieving sub-mm/y radial orbit stability over interannual and decadal periods at regional scales and the challenge of evaluating such an improvement using in situ independent data is discussed.
Towards the 1 mm/y Stability of the Radial Orbit Error at Regional Scales
NASA Technical Reports Server (NTRS)
Couhert, Alexandre; Cerri, Luca; Legeais, Jean-Francois; Ablain, Michael; Zelensky, Nikita P.; Haines, Bruce J.; Lemoine, Frank G.; Bertiger, William I.; Desai, Shailen D.; Otten, Michiel
2014-01-01
An estimated orbit error budget for the Jason-1 and Jason-2 GDR-D solutions is constructed, using several measures of orbit error. The focus is on the long-term stability of the orbit time series for mean sea level applications on a regional scale. We discuss various issues related to the assessment of radial orbit error trends; in particular this study reviews orbit errors dependent on the tracking technique, with an aim to monitoring the long-term stability of all available tracking systems operating on Jason-1 and Jason-2 (GPS, DORIS,SLR). The reference frame accuracy and its effect on Jason orbit is assessed. We also examine the impact of analysis method on the inference of Geographically Correlated Errors as well as the significance of estimated radial orbit error trends versus the time span of the analysis. Thus a long-term error budget of the 10-year Jason-1 and Envisat GDR-D orbit time series is provided for two time scales: interannual and decadal. As the temporal variations of the geopotential remain one of the primary limitations in the Precision Orbit Determination modeling, the overall accuracy of the Jason-1 and Jason-2 GDR-D solutions is evaluated through comparison with external orbits based on different time-variable gravity models. This contribution is limited to an East-West "order-1" pattern at the 2 mm/y level (secular) and 4 mm level (seasonal), over the Jason-2 lifetime. The possibility of achieving sub-mm/y radial orbit stability over interannual and decadal periods at regional scales and the challenge of evaluating such an improvement using in situ independent data is discussed.
Kannan, Vinayagam; Balabathula, Pavan; Divi, Murali K; Thoma, Laura A; Wood, George C
2015-01-01
The effect of formulation and process parameters on drug loading and physical stability of paclitaxel-loaded long-circulating liposomes was evaluated. The liposomes were prepared by hydration-extrusion method. The formulation parameters such as total lipid content, cholesterol content, saturated-unsaturated lipid ratio, drug-lipid ratio and process parameters such as extrusion pressure and number of extrusion cycles were studied and their impact on drug loading and physical stability was evaluated. A proportionate increase in drug loading was observed with increase in the total phospholipid content. Cholesterol content and saturated lipid content in the bilayer showed a negative influence on drug loading. The short-term stability evaluation of liposomes prepared with different drug-lipid ratios demonstrated that 1:60 as the optimum drug-lipid ratio to achieve a loading of 1-1.3 mg/mL without the risk of physical instability. The vesicle size decreased with an increase in the extrusion pressure and number of extrusion cycles, but no significant trends were observed for drug loading with changes in process pressure or number of cycles. The optimization of formulation and process parameters led to a physically stable formulation of paclitaxel-loaded long-circulating liposomes that maintain size, charge and integrity during storage.
Predicting the long-term potential of permeable reactive barriers for treating contaminated groundwater relies on understanding the endpoints of biogeochemical reactions between influent groundwater and the reactive medium. Iron hydroxy carbonate (chukanovite) is frequently obs...
Long-term stability of diurnal salivary cortisol and alpha-amylase secretion patterns.
Skoluda, Nadine; La Marca, Roberto; Gollwitzer, Mario; Müller, Andreas; Limm, Heribert; Marten-Mittag, Birgitt; Gündel, Harald; Angerer, Peter; Nater, Urs M
2017-06-01
This study aimed to investigate long-term stability and variability of diurnal cortisol and alpha-amylase patterns. Diurnal cortisol and alpha-amylase secretion patterns were assessed on a single workday with three waves of measurement across a total time period of 24months in 189 participants. Separate hierarchical linear models were analyzed, with and without a number of potential predictor variables (age, BMI, smoking, chronic stress, stress reactivity). While low long-term stability was found in diurnal cortisol, the stability of diurnal alpha-amylase was moderate across the time period of 24months. Several predictor variables had a positive impact on diurnal cortisol and alpha-amylase secretion patterns averaged across waves. Our findings underpin the notion that long-term stability is not necessarily warranted in longitudinal studies. It is important to choose an appropriate study design when attempting to disentangle clinically and biologically relevant changes from naturally occurring variations in diurnal cortisol and alpha-amylase. Copyright © 2017 Elsevier Inc. All rights reserved.
Some Thoughts on Stability in Nonlinear Periodic Focusing Systems
DOE R&D Accomplishments Database
McMillan, E. M.
1967-09-05
A brief discussion is given of the long-term stability of particle motions through periodic focusing structures containing lumped nonlinear elements. A method is presented whereby one can specify the nonlinear elements in such a way as to generate a variety of structures in which the motion has long-term stability.
Long-term stability of sodium caseinate-stabilized nanoemulsions.
Yerramilli, Manispuritha; Ghosh, Supratim
2017-01-01
Oil-in-water (5 wt%) nanoemulsions were prepared with different concentration (2.5-10 wt%) of sodium caseinate as a sole emulsifier and their long-term storage stability was investigated for 6 months. Previous studies associated with sodium caseinate looked only into nanoemulsion formation; hence the challenges with long-term stability were not addressed. All nanoemulsions displayed an average droplet size <200 nm, which remained unchanged over 6 months. However, all of them displayed rapid creaming due to unabsorbed protein induced depletion flocculation, whose extent increased with protein concentration, although the cream layer formed was weak and re-dispersible upon gentle mixing. Microstructural analysis of the cream layer showed compaction of flocculated nanodroplet network with time leaving the aqueous phase out. Calculation of depletion interaction energy showed an increase in inter-droplet attraction with protein concentration and decrease with a reduction in droplet size, making the nanoemulsions more resistant to flocculation than conventional emulsions. This work aids in understanding the dependence of protein concentration on long-term stability of sodium caseinate-stabilized nanoemulsions.
Li, Huiting; Cui, Fuyi; Liu, Zhiquan; Li, Dapeng
2017-06-01
The fate and long-term effect of different metal oxide (TiO 2 , CuO and ZnO) nanoparticles (NPs) on anaerobic granular sludge (AGS) was evaluated in an anaerobic methanogenic system. Operation stability and structural characteristics of the granules were compared, the metabolism changes in the microbial community were quantified, and NPs fate were investigated. CuO NPs had greatest toxic effect on AGS after extended exposure, whereas ZnO NPs benefited methanogenesis temporarily (no more than 5d). The inhibition on AGS caused by NPs varied due to the unique structure of AGS and different toxic mechanism. Structural changes of AGS provided new evidence that tested NPs have different toxicity. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Wisniewiski, David
2014-03-01
The need to quantify and to improve long-term stability of pressure transducers is a persistent requirement from the aerospace sector. Specifically, the incorporation of real-time pressure monitoring in aircraft landing gear, as exemplified in Tire Pressure Monitoring Systems (TPMS), has placed greater demand on the pressure transducer for improved performance and increased reliability which is manifested in low lifecycle cost and minimal maintenance downtime through fuel savings and increased life of the tire. Piezoresistive (PR) silicon MEMS pressure transducers are the primary choice as a transduction method for this measurement owing to their ability to be designed for the harsh environment seen in aircraft landing gear. However, these pressure transducers are only as valuable as the long-term stability they possess to ensure reliable, real-time monitoring over tens of years. The "heart" of the pressure transducer is the silicon MEMS element, and it is at this basic level where the long-term stability is established and needs to be quantified. A novel High Pressure, High Temperature (HPHT) vessel has been designed and constructed to facilitate this critical measurement of the silicon MEMS element directly through a process of mechanically "floating" the silicon MEMS element while being subjected to the extreme environments of pressure and temperature, simultaneously. Furthermore, the HPHT vessel is scalable to permit up to fifty specimens to be tested at one time to provide a statistically significant data population on which to draw reasonable conclusions on long-term stability. With the knowledge gained on the silicon MEMS element, higher level assembly to the pressure transducer envelope package can also be quantified as to the build-effects contribution to long-term stability in the same HPHT vessel due to its accommodating size. Accordingly, a HPHT vessel offering multiple levels of configurability and robustness in data measurement is presented, along with 10 year long-term stability results.
NASA Astrophysics Data System (ADS)
Kapanen, Mika; Tenhunen, Mikko; Hämäläinen, Tuomo; Sipilä, Petri; Parkkinen, Ritva; Järvinen, Hannu
2006-07-01
Quality control (QC) data of radiotherapy linear accelerators, collected by Helsinki University Central Hospital between the years 2000 and 2004, were analysed. The goal was to provide information for the evaluation and elaboration of QC of accelerator outputs and to propose a method for QC data analysis. Short- and long-term drifts in outputs were quantified by fitting empirical mathematical models to the QC measurements. Normally, long-term drifts were well (<=1%) modelled by either a straight line or a single-exponential function. A drift of 2% occurred in 18 ± 12 months. The shortest drift times of only 2-3 months were observed for some new accelerators just after the commissioning but they stabilized during the first 2-3 years. The short-term reproducibility and the long-term stability of local constancy checks, carried out with a sealed plane parallel ion chamber, were also estimated by fitting empirical models to the QC measurements. The reproducibility was 0.2-0.5% depending on the positioning practice of a device. Long-term instabilities of about 0.3%/month were observed for some checking devices. The reproducibility of local absorbed dose measurements was estimated to be about 0.5%. The proposed empirical model fitting of QC data facilitates the recognition of erroneous QC measurements and abnormal output behaviour, caused by malfunctions, offering a tool to improve dose control.
Long-term stability and properties of zirconia ceramics for heavy duty diesel engine components
NASA Technical Reports Server (NTRS)
Larsen, D. C.; Adams, J. W.
1985-01-01
Physical, mechanical, and thermal properties of commercially available transformation-toughened zirconia are measured. Behavior is related to the material microstructure and phase assemblage. The stability of the materials is assessed after long-term exposure appropriate for diesel engine application. Properties measured included flexure strength, elastic modulus, fracture toughness, creep, thermal shock, thermal expansion, internal friction, and thermal diffusivity. Stability is assessed by measuring the residual property after 1000 hr/1000C static exposure. Additionally static fatigue and thermal fatigue testing is performed. Both yttria-stabilized and magnesia-stabilized materials are compared and contrasted. The major limitations of these materials are short term loss of properties with increasing temperature as the metastable tetragonal phase becomes more stable. Fine grain yttria-stabilized material (TZP) is higher strength and has a more stable microstructure with respect to overaging phenomena. The long-term limitation of Y-TZP is excessive creep deformation. Magnesia-stabilized PSZ has relatively poor stability at elevated temperature. Overaging, decomposition, and/or destabilization effects are observed. The major limitation of Mg-PSZ is controlling unwanted phase changes at elevated temperature.
Dobran, Mauro; Esposito, Domenico Paolo; Gladi, Maurizio; Scerrati, Massimo; Iacoangeli, Maurizio
2018-01-01
Study Design Retrospective study with long-term follow-up. Purpose To evaluate the long-term incidence of adjacent segment degeneration (ASD) and clinical outcomes in a consecutive series of patients who underwent spinal decompression associated with dynamic or hybrid stabilization with a Flex+TM stabilization system (SpineVision, Antony, France) for lumbar spinal stenosis. Overview of Literature The incidence of ASD and clinical outcomes following dynamic or hybrid stabilization with the Flex+TM system used for lumbar spinal stenosis have not been well investigated. Methods Twenty-one patients with lumbar stenosis and probable post-decompressive spinal instability underwent decompressive laminectomy followed by spinal stabilization using the Flex+TM stabilization system. The indication for a mono-level dynamic stabilization was a preoperative magnetic resonance imaging (MRI) demonstrating evidence of severe disc disease associated with severe spinal stenosis. The hybrid stabilization (rigid-dynamic) system was used for multilevel laminectomies with associated initial degenerative scoliosis, first-grade spondylolisthesis, or rostral pathology. Results The improvement in Visual Analog Scale and Oswestry Disability Index scores at follow-up were statistically significant (p<0.0001 and p<0.0001, respectively). At the 5–8-year follow-up, clinical examination, MRI, and X-ray findings showed an ASD complication with pain and disability in one of 21 patients. The clinical outcomes were similar in patients treated with dynamic or hybrid fixation. Conclusions Patients treated with laminectomy and Flex+TM stabilization presented a satisfactory clinical outcome after 5–8 years of follow-up, and ASD incidence in our series was 4.76% (one patient out of 21). We are aware that this is a small series, but our long-term follow-up may be sufficient to contribute to the expanding body of literature on the development of symptomatic ASD associated with dynamic or hybrid fixation. PMID:29713407
Kibria, Md Golam; Qiao, Ruimin; Yang, Wanli; Boukahil, Idris; Kong, Xianghua; Chowdhury, Faqrul Alam; Trudeau, Michel L; Ji, Wei; Guo, Hong; Himpsel, F J; Vayssieres, Lionel; Mi, Zetian
2016-10-01
The atomic-scale origin of the unusually high performance and long-term stability of wurtzite p-GaN oriented nanowire arrays is revealed. Nitrogen termination of both the polar (0001¯) top face and the nonpolar (101¯0) side faces of the nanowires is essential for long-term stability and high efficiency. Such a distinct atomic configuration ensures not only stability against (photo) oxidation in air and in water/electrolyte but, as importantly, also provides the necessary overall reverse crystal polarization needed for efficient hole extraction in p-GaN. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Xue, Qiang; Wang, Ping; Li, Jiang-Shan; Zhang, Ting-Ting; Wang, Shan-Yong
2017-01-01
Long-term leaching behavior of contaminant from stabilization/solidification (S/S) treated waste stays unclear. For the purpose of studying long-term leaching behavior and leaching mechanism of lead from cement stabilized soil under different pH environment, semi-dynamic leaching test was extended to two years to investigate leaching behaviors of S/S treated lead contaminated soil. Effectiveness of S/S treatment in different scenarios was evaluated by leachability index (LX) and effective diffusion coefficient (D e ). In addition, the long-term leaching mechanism was investigated at different leaching periods. Results showed that no significant difference was observed among the values of the cumulative release of Pb, D e and LX in weakly alkaline and weakly acidic environment (pH value varied from 5.00 to 10.00), and all the controlling leaching mechanisms of the samples immersed in weakly alkaline and weakly acidic environments turned out to be diffusion. Strong acid environment would significantly affect the leaching behavior and leaching mechanism of lead from S/S monolith. The two-year variation of D e appeared to be time dependent, and D e values increased after the 210 th day in weakly alkaline and weakly acidic environment. Copyright © 2016 Elsevier Ltd. All rights reserved.
Dynamical Stability and Long-term Evolution of Rotating Stellar Systems
NASA Astrophysics Data System (ADS)
Varri, Anna L.; Vesperini, E.; McMillan, S. L. W.; Bertin, G.
2011-05-01
We present the first results of an extensive survey of N-body simulations designed to investigate the dynamical stability and the long-term evolution of two new families of self-consistent stellar dynamical models, characterized by the presence of internal rotation. The first family extends the well-known King models to the case of axisymmetric systems flattened by solid-body rotation while the second family is characterized by differential rotation. The equilibrium configurations thus obtained can be described in terms of two dimensionless parameters, which measure the concentration and the amount of rotation, respectively. Slowly rotating configurations are found to be dynamically stable and we followed their long-term evolution, in order to evaluate the interplay between collisional relaxation and angular momentum transport. We also studied the stability of rapidly rotating models, which are characterized by the presence of a toroidal core embedded in an otherwise quasi-spherical configuration. In both cases, a description in terms of the radial and global properties, such as the ratio between the ordered kinetic energy and the gravitational energy of the system, is provided. Because the role of angular momentum in the process of cluster formation is only partly understood, we also undertook a preliminary investigation of the violent relaxation of simple systems initially characterized by approximate solid-body rotation. The properties of the final equilibrium configurations thus obtained are compared with those of the above-described family of differentially rotating models.
Li, Chung-Chen; Beck, Ingrid A; Seidel, Kristy D; Frenkel, Lisa M
2004-08-01
The stability of human immunodeficiency virus type 1 (HIV-1) DNA in whole blood collected on filter paper (FTA Card) was evaluated. After >4 years of storage at room temperature in the dark our qualitative assay detected virus at a rate similar to that of our initial test (58 of 60, 97%; P = 0.16), suggesting long-term HIV-1 DNA stability.
Li, Chung-Chen; Beck, Ingrid A.; Seidel, Kristy D.; Frenkel, Lisa M.
2004-01-01
The stability of human immunodeficiency virus type 1 (HIV-1) DNA in whole blood collected on filter paper (FTA Card) was evaluated. After >4 years of storage at room temperature in the dark our qualitative assay detected virus at a rate similar to that of our initial test (58 of 60, 97%; P = 0.16), suggesting long-term HIV-1 DNA stability. PMID:15297546
Equilibrium high entropy alloy phase stability from experiments and thermodynamic modeling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saal, James E.; Berglund, Ida S.; Sebastian, Jason T.
Long-term stability of high entropy alloys (HEAs) is a critical consideration for the design and practical application of HEAs. It has long been assumed that many HEAs are a kinetically-stabilized metastable structure, and recent experiments have confirmed this hypothesis by observing HEA ecomposition after long-termequilibration. In the presentwork,we demonstrate the use of the CALculation of PHAse Diagrams (CALPHAD) approach to predict HEA stability and processing parameters, comparing experimental long-term annealing observations to CALPHAD phase diagrams from a commercially-available HEA database. As a result, we find good agreement between single- and multi-phase predictions and experiments.
Equilibrium high entropy alloy phase stability from experiments and thermodynamic modeling
Saal, James E.; Berglund, Ida S.; Sebastian, Jason T.; ...
2017-10-29
Long-term stability of high entropy alloys (HEAs) is a critical consideration for the design and practical application of HEAs. It has long been assumed that many HEAs are a kinetically-stabilized metastable structure, and recent experiments have confirmed this hypothesis by observing HEA ecomposition after long-termequilibration. In the presentwork,we demonstrate the use of the CALculation of PHAse Diagrams (CALPHAD) approach to predict HEA stability and processing parameters, comparing experimental long-term annealing observations to CALPHAD phase diagrams from a commercially-available HEA database. As a result, we find good agreement between single- and multi-phase predictions and experiments.
Long-term outcomes of bone augmentation on soft and hard-tissue stability: a systematic review.
Lutz, Rainer; Neukam, Friedrich W; Simion, Massimo; Schmitt, Christian M
2015-09-01
Peri-implant hard-tissue augmentation is a widely used clinical procedure. The present review aimed to analyse the current literature regarding medium- and long-term data concerning the stability of peri-implant tissues after hard-tissue augmentation prior or immediately with implant placement. An electronic literature search was performed using Medline (PubMed) databases detecting clinical studies focusing on hard- and soft-tissue stability around dental implants placed either in augmented alveolar ridges or simultaneously with peri-implant bone grafting. The search was limited to articles published between 1995 and December 2014, focusing on clinical studies with a prospective study design assessing peri-implant bone and soft tissue stability over time with a minimum follow-up of 12 months. Recent publications were also searched manually to find any relevant studies that might have been missed using the search criteria noted above. Thirty-seven articles met the inclusion criteria and were included in this systematic review. Since the outcome measures and methods, as well as types of grafts and implants used were so heterogeneous, the performance of meta-analysis was impossible. The highest level of evidence was achieved by randomized clinical trials. Different hard-tissue augmentation procedures seem to show stable peri-implant tissues, although, up to now, long-term stability of the augmented buccal bone is assessed by only few studies. Further research should concentrate on combining three-dimensional radiographic data with non-invasive methods as digital surface measuring techniques or ultrasound evaluation. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Ariizumi, Masahiro; Kubo, Megumi; Handa, Akihiro; Hayakawa, Takashi; Matsumiya, Kentaro; Matsumura, Yasuki
2017-04-01
Mayonnaise-like oil-in-water emulsions with different stabilities-evaluated from the degree of macroscopic defects, e.g., syneresis-were prepared by different formulations and processing conditions (egg yolk weight, homogenizer speed, and vegetable oil temperature). Emulsions prepared with lower egg yolk content were destabilized for shorter periods. The long-term stability of emulsions was weakly related to initial properties, e.g., oil droplet distribution and protein coverage at the interface. Protein aggregation between oil droplets was observed and would be responsible for the instability of emulsions exhibited by the appearance defects. SDS-PAGE results for adsorbed and unadsorbed proteins at the O/W interface suggested that predominant constituents adsorbed onto the interface were egg white proteins as compared with egg yolk components when the amount of added egg yolk was low. In present condition, egg white proteins adsorbed at the O/W interface could be a bridge of neighboring oil droplets thereby causing flocculation in emulsions.
Microstructural Evolution of Thor™ 115 Creep-Strength Enhanced Ferritic Steel
NASA Astrophysics Data System (ADS)
Ortolani, Matteo; D'Incau, Mirco; Ciancio, Regina; Scardi, Paolo
2017-12-01
A new ferritic steel branded as Thor™ 115 has been developed to enhance high-temperature resistance. The steel design combines an improved oxidation resistance with long-term microstructural stability. The new alloy, cast to different product forms such as plates and tubes, was extensively tested to assess the high-temperature time-dependent mechanical behavior (creep). The main strengthening mechanism is precipitation hardening by finely dispersed carbide and nitride phases. Information on the evolution of secondary phases and time-temperature-precipitation behavior of the alloy, essential to ensure long-term property stability, was obtained by scanning transmission electron microscopy with energy dispersive spectroscopy, and by X-ray Powder Diffraction on specimens aged up to 50,000 hours. A thermodynamic modeling supports presentation and evaluation of the experimental results. The evolution of precipitates in the new alloy confirms the retention of the strengthening by secondary phases, even after long-term exposure at high temperature. The deleterious conversion of nitrides into Z phase is shown to be in line with, or even slower than that of the comparable ASME grade 91 steel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillips, S.J.; Fischer, D.D.; Crawford, R.C.
1982-06-01
Rockwell Hanford Operations is currently involved in an extensive effort to perform interim ground surface stabilization activities at retired low-level waste burial grounds located at the Hanford Site, Richland, Washington. The principal objective of these activities is to promote increased occupational and radiological safety at burial grounds. Interim stabilization activities include: (1) load testing (traversing burial ground surfaces with heavy equipment to promote incipient collapse of void spaces within the disposal structure and overburden), (2) barrier placement (placement of a {ge} 0.6 m soil barrier over existing overburden), and (3) revegetation (establishment of shallow rooted vegetation on the barrier tomore » mitigate deep rooted plant growth and to reduce erosion). Low-level waste disposal caissons were used in 300 Area Burial Grounds as internment structures for containerized liquid wastes. These caissons, by virtue of their contents, design and methods of closure, require long-term performance evaluation. As an initial activity to evaluate long-term performance, the accurate location of these structures is required. This topical report summarizes engineering activities used to locate caissons in the subsurface environment at the Burial Ground. Activities were conducted to locate caissons during surface stabilization activities. The surface locations were marked, photographed, and recorded on an as built engineering drawing. The recorded location of these caissons will augment long-term observations of confinement structure and engineered surface barrier performance. In addition, accurate caisson location will minimize occupational risk during monitoring and observation activities periodically conducted at the burial ground.« less
Makris, Konstantinos C; Harris, Willie G; O'Connor, George A; Obreza, Thomas A
2004-12-15
Drinking-water treatment residuals (WTRs) can immobilize excess soil phosphorus (P), but little is known about the long-term P retention by WTRs. To evaluate the long-term P sorption characteristics of one Fe- and one Al-based WTR, physicochemical properties pertinent to time-dependency and hysteresis of P sorption were assessed. This study also investigated the P sorption mechanisms that could affect the long-term stability of sorbed P by WTRs. Phosphorus sorption kinetics by the WTRs exhibited a slow phase that followed an initial rapid phase, as typically occurs with metal hydroxides. Phosphorus sorption maxima for both Fe- and Al-based WTRs exceeded 9100 mg of P kg(-1) and required a greater specific surface area (SSA) than would be available based on BET-N2 calculations. Electron microprobe analyses of cross-sectional, P-treated particles showed three-dimensional P sorption by WTRs. Carbon dioxide gas sorption was greater than N2, suggesting steric restriction of N2 diffusion by narrow micropore openings. Phosphorus-treated Co2 SSAs were reduced by P treatment, suggesting P sorption by micropores (5-20 A). Mercury intrusion porosimetry indicated negligible macroporosity (pores > 500 A). Slow P sorption kinetics by WTRs may be explained by intraparticle P diffusion in micropores. Micropore-bound P should be stable and immobilized over long periods.
ERIC Educational Resources Information Center
Lander, Jenny
2010-01-01
The present investigation explored the stability of scores on the Wechsler Intelligence Scale for Children-IV (WISC-IV) over approximately a three-year period. Previous research has suggested that some children with Learning Disabilities (LD) do not demonstrate long-term stability of intelligence. Legally, school districts are no longer required…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-15
... to the long-term economic stability of the region. Please see the NIST MEP Web site, http://www.nist... region, and contribute to the long-term economic stability of the region. Competitive projects will use...
PERINATAL DIMETHYLTIN EXPOSURE ALTERS SPATIAL LEARNING ABILITY IN ADULT RATS.
Dimethyltin (DMT) is widely used as a heat and light stabilizer in PVC and CPVC piping, and has been detected in domestic water supplies. Due to the lack of developmental neurotoxicity data on DMT, we initiated studies to evaluate long-term neurobehavioral changes in offspring fo...
Some Thoughts on Stability in Nonlinear Periodic Focusing Systems [Addendum
DOE R&D Accomplishments Database
McMillan, Edwin M.
1968-03-29
Addendum to September 5, 1967 report with the same title and with the abstract: A brief discussion is given of the long-term stability of particle motions through periodic focusing structures containing lumped nonlinear elements. A method is presented whereby one can specify the nonlinear elements in such a way as to generate a variety of structures in which the motion has long-term stability.
NASA Technical Reports Server (NTRS)
Tien, John K.
1990-01-01
The long term interdiffusional stability of tungsten fiber reinforced niobium alloy composites is addressed. The matrix alloy that is most promising for use as a high temperature structural material for reliable long-term space power generation is Nb1Zr. As an ancillary project to this program, efforts were made to assess the nature and kinetics of interphase reaction between selected beryllide intermetallics and nickel and iron aluminides.
Assessment of the short-term radiometric stability between Terra MODIS and Landsat 7 ETM+ sensors
Choi, Taeyoung; Xiong, Xiaoxiong; Chander, Gyanesh; Angal, A.
2009-01-01
Short-term radiometric stability was evaluated using continuous ETM+ scenes within a single orbit (contact period) and the corresponding MODIS scenes for the four matching solar reflective visible and near-infrared (VNIR) band pairs between the two sensors. The near-simultaneous earth observations were limited by the smaller swath size of ETM+ (183 km) compared to MODIS (2330 km). Two sets of continuous granules for Terra MODIS and Landsat 7 ETM+ were selected and mosaicked based on pixel geolocation information for noncloudy pixels over the African continent. The matching pixel pairs were resampled from a fine to a coarse pixel resolution, and the at-sensor spectral radiance values for a wide dynamic range of the sensors were compared and analyzed, covering various surface types. The following study focuses on radiometric stability analysis from the VNIR band-pairs of ETM+ and MODIS. The Libya-4 desert target was included in the path of this continuous orbit, which served as a verification point between the short-term and the long-term trending results from previous studies. MODTRAN at-sensor spectral radiance simulation is included for a representative desert surface type to evaluate the consistency of the results.
NASA Astrophysics Data System (ADS)
Salah, Faisal Mohammed; Jaya, Ramadhansyah Putra; Mohamed, Azman; Hassan, Norhidayah Abdul; Rosni, Nurul Najihah Mad; Mohamed, Abdullahi Ali; Agussabti
2017-12-01
The influence of styrene butadiene rubber (SBR) on asphaltic concrete properties at different aging conditions was presented in this study. These aging conditions were named as un-aged, short-term, and long-term aging. The conventional asphalt binder of penetration grade 60/70 was used in this work. Four different levels of SBR addition were employed (i.e., 0 %, 1 %, 3 %, and 5 % by binder weight). Asphalt concrete mixes were prepared at selected optimum asphalt content (5 %). The performance was evaluated based on Marshall Stability, resilient modulus, and dynamic creep tests. Results indicated the improving stability and permanent deformation characteristics that the mixes modified with SBR polymer have under aging conditions. The result also showed that the stability, resilient modulus, and dynamic creep tests have the highest rates compared to the short-term aging and un-aged samples. Thus, the use of 5 % SBR can produce more durable asphalt concrete mixtures with better serviceability.
NASA Astrophysics Data System (ADS)
Takaya, Satoshi; Tanamoto, Tetsufumi; Noguchi, Hiroki; Ikegami, Kazutaka; Abe, Keiko; Fujita, Shinobu
2017-04-01
Among the diverse applications of spintronics, security for internet-of-things (IoT) devices is one of the most important. A physically unclonable function (PUF) with a spin device (spin transfer torque magnetoresistive random access memory, STT-MRAM) is presented. Oxide tunnel barrier breakdown is used to realize long-term stability for PUFs. A secure PUF has been confirmed by evaluating the Hamming distance of a 32-bit STT-MRAM-PUF fabricated using 65 nm CMOS technology.
Characterization of the Nimbus-7 SBUV radiometer for the long-term monitoring of stratospheric ozone
NASA Technical Reports Server (NTRS)
Cebula, Richard P.; Park, H.; Heath, D. F.
1988-01-01
Precise knowledge of in-orbit sensitivity change is critical for the successful monitoring of stratospheric ozone by satellite-based remote sensors. This paper evaluates those aspects of the in-flight operation that influence the long-term stability of the upper stratospheric ozone measurements made by the Nimbus-7 SBUV spectroradiometer and chronicles methods used to maintain the long-term albedo calibration of this UV sensor. It is shown that the instrument's calibration for the ozone measurement, the albedo calibration, has been maintained over the first 6 yr of operation to an accuracy of approximately + or - 2 percent. The instrument's wavelength calibration is shown to drift linearly with time. The knowledge of the SBUV wavelength assignment is maintained to a 0.02-nm precision.
Edelhoff, Daniel; Beuer, Florian; Schweiger, Josef; Brix, Oliver; Stimmelmayr, Michael; Guth, Jan-Frederik
2012-06-01
Complex rehabilitations represent a particular challenge for the restorative team, especially if the vertical dimension of occlusion (VDO) needs to be reconstructed or redefined. The use of provisional acrylic or composite materials allows clinicians to evaluate the treatment objective over a certain period of time and therefore generates a high predictability of the definitive rehabilitation in terms of esthetics and function. CAD/CAM technology enables the use of prefabricated polymer materials, which are fabricated under industrial conditions to form a highly homogeneous structure compared with those of direct fabrication. This increases long-term stability, biocompatibility, and resistance to wear. Furthermore, they offer more suitable CAD/CAM processing characteristics and can be used in thinner thicknesses than ceramic restorative materials. Also, based on the improved long-term stability, the transfer into the definitive restoration can be divided into multiple treatment steps. This article presents different clinical cases with minimally invasive indications for CAD/CAM-fabricated temporary restorations for the pretreatment of complex cases.
From Cell to Module: Fabrication and Long-term Stability of Dye-sensitized Solar Cells
NASA Astrophysics Data System (ADS)
Nursam, N. M.; Hidayat, J.; Muliani, L.; Anggraeni, P. N.; Retnaningsih, L.; Idayanti, N.
2017-07-01
Dye-sensitized solar cell (DSSC), which has been firstly developed by Graetzel et al back in 1991, has attracted a considerable interest since its discovery. However, two of the main challenges that the DSSC technology will have to overcome towards commercialization involve device scale-up and long-term stability. In our group, the fabrication technology of DSSC has been developed from laboratory to module scale over the past few years, nevertheless, the long-term stability has still became a major concern. In this contribution, the long-term DSSC performance in relation to their scale-up from cell to module is investigated. The photoelectrode of the DSSCs were fabricated using nanocrystalline titanium dioxide materials that were subsequently sensitized using ruthenium-based dye. Additionally, TiCl4 pre- and post-treatment were carried out to enhance the overall device efficiency. When fabricated as cells, the DSSC prototypes showed relatively stable performance during repeated tests over three months. In order to increase the output power of the solar cells, the DSSCs were then connected in a Z-type series connection to obtain sub-module panels. The DSSC sub-modules exhibit poor stability, particularly as indicated by the significant decrease in the short circuit current (ISC ). Herein, the effect of photoelectrode and sealant materials as well as module design are investigated, highlighting their profound influence upon the DSSC efficiency and long-term stability.
Long-term Results for the BacJac Interspinous Device in Lumbar Spine Degenerative Disease.
Spallone, Aldo; Lavorato, Luigi; Belvisi, Daniele
2018-05-14
To evaluate the long-term results of using the BacJac interspinous device (Pioneer Surgical Technology Inc.) in a series of patients with degenerative lumbar spine disease. Forty-one patients undergoing lumbar surgery with implantation of a BacJac device from 2009 to 2012 were enrolled in the present study. Patients were evaluated using the Oswestry Disability Scale (ODI). Although all patients showed a significant improvement of the ODI score immediately after surgery, only 41% of patients showed a satisfactory outcome. We observed worse results in the patients operated on at the L3-L4 level and in whom the device was implanted in a segment different from the one where surgical decompression had been performed. Weight gain in the months after surgery was also a poor outcome-influencing factor. This study confirms what is already suggested in the relevant literature regarding the long-term inefficacy of the so-called dynamic stabilization devices. Georg Thieme Verlag KG Stuttgart · New York.
'Enzyme Test Bench': A biochemical application of the multi-rate modeling
NASA Astrophysics Data System (ADS)
Rachinskiy, K.; Schultze, H.; Boy, M.; Büchs, J.
2008-11-01
In the expanding field of 'white biotechnology' enzymes are frequently applied to catalyze the biochemical reaction from a resource material to a valuable product. Evolutionary designed to catalyze the metabolism in any life form, they selectively accelerate complex reactions under physiological conditions. Modern techniques, such as directed evolution, have been developed to satisfy the increasing demand on enzymes. Applying these techniques together with rational protein design, we aim at improving of enzymes' activity, selectivity and stability. To tap the full potential of these techniques, it is essential to combine them with adequate screening methods. Nowadays a great number of high throughput colorimetric and fluorescent enzyme assays are applied to measure the initial enzyme activity with high throughput. However, the prediction of enzyme long term stability within short experiments is still a challenge. A new high throughput technique for enzyme characterization with specific attention to the long term stability, called 'Enzyme Test Bench', is presented. The concept of the Enzyme Test Bench consists of short term enzyme tests conducted under partly extreme conditions to predict the enzyme long term stability under moderate conditions. The technique is based on the mathematical modeling of temperature dependent enzyme activation and deactivation. Adapting the temperature profiles in sequential experiments by optimum non-linear experimental design, the long term deactivation effects can be purposefully accelerated and detected within hours. During the experiment the enzyme activity is measured online to estimate the model parameters from the obtained data. Thus, the enzyme activity and long term stability can be calculated as a function of temperature. The results of the characterization, based on micro liter format experiments of hours, are in good agreement with the results of long term experiments in 1L format. Thus, the new technique allows for both: the enzyme screening with regard to the long term stability and the choice of the optimal process temperature. The presented article gives a successful example for the application of multi-rate modeling, experimental design and parameter estimation within biochemical engineering. At the same time, it shows the limitations of the methods at the state of the art and addresses the current problems to the applied mathematics community.
Schenck, Robert C.; Richter, Dustin L.; Wascher, Daniel C.
2014-01-01
Background: Traumatic knee dislocation is becoming more prevalent because of improved recognition and increased exposure to high-energy trauma, but long-term results are lacking. Purpose: To present 2 cases with minimum 20-year follow-up and a review of the literature to illustrate some of the fundamental principles in the management of the dislocated knee. Study Design: Review and case reports. Methods: Two patients with knee dislocations who underwent multiligamentous knee reconstruction were reviewed, with a minimum 20-year follow-up. These patients were brought back for a clinical evaluation using both subjective and objective measures. Subjective measures include the following scales: Lysholm, Tegner activity, visual analog scale (VAS), Short Form–36 (SF-36), International Knee Documentation Committee (IKDC), and a psychosocial questionnaire. Objective measures included ligamentous examination, radiographic evaluation (including Telos stress radiographs), and physical therapy assessment of function and stability. Results: The mean follow-up was 22 years. One patient had a vascular injury requiring repair prior to ligament reconstruction. The average assessment scores were as follows: SF-36 physical health, 52; SF-36 mental health, 59; Lysholm, 92; IKDC, 86.5; VAS involved, 10.5 mm; and VAS uninvolved, 2.5 mm. Both patients had excellent stability and were functioning at high levels of activity for their age (eg, hiking, skydiving). Both patients had radiographic signs of arthritis, which lowered 1 subject’s IKDC score to “C.” Conclusion: Knee dislocations have rare long-term excellent results, and most intermediate-term studies show fair to good functional results. By following fundamental principles in the management of a dislocated knee, patients can be given the opportunity to function at high levels. Hopefully, continued advances in the evaluation and treatment of knee dislocations will improve the long-term outcomes for these patients in the future. PMID:26535332
Hsu, Ya-Chuan
2011-09-01
: Diverse social and recreational activities in elder care institutions have been provided to enrich a person's mental well-being amidst what is a relatively monotonous life. However, few instruments that measure the social activities of long-term care residents are available. : This study was designed to develop a culturally sensitive instrument (Socially Supportive Activity Inventory, SSAI) to assess quantity and quality of social activities for long-term care institutions and validate the instrument's psychometric properties. : The SSAI was developed on the basis of the social support theory, a synthesis of literature, and Taiwanese cultural mores. The instrument was rigorously subjected to a two-stage process to evaluate its reliability and validity. In Stage 1, six experts from diverse backgrounds were recruited to evaluate instrument items and estimate the content validity of the instrument using a content validity questionnaire. Items were modified and refined on the basis of the responses of the expert panel and a set of criteria. After obtaining approval from a university institutional review board, in the second stage of evaluating test-retest reliability, a convenience sample of 10 Taiwanese institutionalized elders in a pilot study, recruited from a nursing home, completed the revised instrument at two separate times over 2 weeks. : Results showed a content validity of .96. Test-retest reliability from a sample of 10 participants yielded stability coefficients of .76-1.00. The stability coefficient was 1.00 for the component of frequency, .76-1.00 for the component of meaningfulness, and .78-1.00 for the component of enjoyment. : The SSAI is a highly relevant and reliable culturally based instrument that can measure social activity in long-term care facilities. Because of the pilot nature of this study, future directions include further exploration of the SSAI instrument's psychometric properties. This should be done by enlarging the sample size to include more long-term care facilities and individual participants. Future studies can utilize diverse measures of social activity for comparison and validation of the SSAI.
NASA Technical Reports Server (NTRS)
Aniversario, R. B.; Harvey, S. T.; Mccarty, J. E.; Parsons, J. T.; Peterson, D. C.; Pritchett, L. D.; Wilson, D. R.; Wogulis, E. R.
1982-01-01
Results of tests conducted to demonstrate that composite structures save weight, possess long term durability, and can be fabricated at costs competitive with conventional metal structures are presented with focus on the use of graphite-epoxy in the design of a stabilizer for the Boeing 737 aircraft. Component definition, materials evaluation, material design properties, and structural elements tests are discussed. Fabrication development, as well as structural repair and inspection are also examined.
Bowtle, William; Kanyowa, Lionel; Mackenzie, Mark; Higgins, Paul
2011-06-01
The industrial take-up of liquid-fill hard capsule technology is limited in part by lack of published long-term physical and chemical stability data which demonstrate the robustness of the system. To assess the effects of extreme long-term storage on liquid-fill capsule product quality and integrity, with respect to both the capsules per se and a standard blister-pack type (foil-film blister). Fourteen sets of stored peroxidation-sensitive liquid-fill hard gelatin capsule product samples, originating ~20 years from the current study, were examined with respect to physical and selected chemical properties, together with microbiological evaluation. All sets retained physical integrity of capsules and blister-packs. Capsules were free of leaks, gelatin cross-linking, and microbiological growth. Eight samples met a limit (anisidine value, 20) commonly used as an index of peroxidation for lipid-based products with shelf lives of 2-3 years. Foil-film blister-packs using PVC or PVC-PVdC as the thermoforming film were well-suited packaging components for the liquid-fill capsule format. The study confirms the long-term physical robustness of the liquid-fill hard capsule format, together with its manufacturing and banding processes. It also indicates that various peroxidation-sensitive products using the capsule format may be maintained satisfactorily over very prolonged storage periods.
Marriage Counselling in Australia: An Evaluation.
ERIC Educational Resources Information Center
Wolcott, Ilene; Glezer, Helen
A study was conducted of the effectiveness of marriage counseling with respect to marital status and the long-term stability of relationships. Data were gathered from clients of approved Australian marriage counseling agencies (n=540) who took a pre-counseling survey during a 4-week period in October-November 1987 and a post-counseling survey 8…
USDA-ARS?s Scientific Manuscript database
In the U.S., concerns over the long-term sustainability of peat, perlite, and other media components have led to searches for alternative materials. FiberFill, a synthetic fiber made of recyclable polyethylene terephthalate, and Tencel, a cellulose fiber, are new materials with potential as substra...
NASA Astrophysics Data System (ADS)
Velgosová, Oksana; Mražíková, Anna
2017-12-01
In this paper the influence of algae life cycle and the solutions pH on the green synthesis of colloidal Ag nanoparticles (AgNPs) as well as effect of different storage conditions on AgNPs long-term stability was investigated. Silver nanoparticles were biologically synthesized using extracts of Parachlorella kessleri algae cultivated 1, 2, 3 and 4 weeks. The formation of AgNPs was monitored using a UV-vis spectrophotometer and verified by TEM observation. The results confirmed formation of polyhedron and/or near polyhedron AgNPs, ranging between 5 and 60 nm in diameter. The age of algae influenced the synthesis rate and an amount of AgNPs in solution. The best results were obtained using tree weeks old algae. UV-vis analysis and TEM observation also revealed that the size and the stability of AgNPs depend on the pH of solution. AgNPs formed in solutions of higher pH (8 and 10) are polyhedron, fine, with narrow size interval and stabile. Nanoparticles formed in solutions of low pH (2, 4 and 6) started to lose their stability on 10th day of experiment, and the particle size interval was wide. The long-term stability of AgNPs can be influenced by light and temperature conditions. The most significant stability loss was observed at day light and room temperature (21°C). After 200-days significant amount of agglomerated particles settled on the bottom of the Erlenmeyer flask. AgNPs stored at dark and room temperature showed better long-term stability, weak particles agglomeration was observed. AgNPs stored at dark and at temperature 5°C showed the best long-term stability. Such AgNPs remained spherical, fine (5-20 nm), with narrow size interval and stable (no agglomeration) even after more than six months.
Dong, Xue; Zhu, Qin; Dai, Yaqing; He, Jianfei; Pan, Hongyang; Chen, Jie; Zheng, Zong-Ping
2016-02-01
The aim of this study is to improve artocarpanone solubility by developing an O/W microemulsion with the evaluation of its antibrowning effects. The chemical and physical stabilities as well as antibrowning effects in apple juice were also evaluated. The formulation of artocarpanone microemulsion consisted of 4% w/w of ethyl butyrate, 10.67% w/w of Tween 80, 5.33% w/w of polyethylene glycol 400, and 80% w/w of water, with a maximum solubility of artocarpanone up to 10.54 ± 0.01 mg/mL, at least 3000-folds increase in solubility compared that in water. Encapsulating artocarpanone and ascorbic acid (VC) into microemulsion simultaneously decreased modest artocarpanone solubility whereas improving its stability in long-term storage. Blank, artocarpanone and artocarpanone-Vc-loaded microemulsions demonstrated steadily during accelerated and long-term storage. Artocarpanone-Vc-loaded microemulsion showed strong antibrowning effects in apple juice at room temperature in 24h, suggesting that artocarpanone-Vc-loaded microemulsion is a good antibrowning agent for apple juices. Copyright © 2015 Elsevier Ltd. All rights reserved.
Validation of 10 years of SAO OMI Ozone Profiles with Ozonesonde and MLS Observations
NASA Astrophysics Data System (ADS)
Huang, G.; Liu, X.; Chance, K.; Bhartia, P. K.
2015-12-01
To evaluate the accuracy and long-term stability of the SAO OMI ozone profile product, we validate ~10 years of ozone profile product (Oct. 2004-Dec. 2014) against collocated ozonesonde and MLS data. Ozone profiles as well stratospheric, tropospheric, lower tropospheric ozone columns are compared with ozonesonde data for different latitude bands, and time periods (e.g., 2004-2008/2009-2014 for without/with row anomaly. The mean biases and their standard deviations are also assessed as a function of time to evaluate the long-term stability and bias trends. In the mid-latitude and tropical regions, OMI generally shows good agreement with ozonesonde observations. The mean ozone profile biases are generally within 6% with up to 30% standard deviations. The biases of stratospheric ozone columns (SOC) and tropospheric ozone columns (TOC) are -0.3%-2.2% and -0.2%-3%, while standard deviations are 3.9%-5.8% and 14.4%-16.0%, respectively. However, the retrievals during 2009-2014 show larger standard deviations and larger temporal variations; the standard deviations increase by ~5% in the troposphere and ~2% in the stratosphere. Retrieval biases at individual levels in the stratosphere and upper troposphere show statistically significant trends and different trends for 2004-2008 and 2009-2014 periods. The trends in integrated ozone partial columns are less significant due to cancellation from various layers, except for significant trend in tropical SOC. These results suggest the need to perform time dependent radiometric calibration to maintain the long-term stability of this product. Similarly, we are comparing the OMI stratospheric ozone profiles and SOC with collocated MLS data, and the results will be reported.
High-Performing, Low-Temperature-Operating, Long-Lifetime Aerospace Lubricants
NASA Technical Reports Server (NTRS)
Joshi, Prakash
2015-01-01
Long-duration space exploration will require spacecraft systems that can operate effectively over several years with minimal or no maintenance. Aerospace lubricants are key components of spacecraft systems. Physical Sciences Inc., has synthesized and characterized novel ionic liquids for use in aerospace lubricants that contribute to decreased viscosity, friction, and wear in aerospace systems. The resulting formulations offer low vapor pressure and outgassing properties and thermal stability up to 250 C. They are effective for use at temperatures as low as -70 C and provide long-term operational stability in aerospace systems. In Phase II, the company scaled several new ionic liquids and evaluated a novel formulation in a NASA testbed. The resulting lubricant compounds will offer lower volatility, decreased corrosion, and better tribological characteristics than standard liquid lubricants, particularly at lower temperatures.
Kurfirst, Vojtech; Mokrácek, Aleš; Canádyová, Júlia; Frána, Radim; Zeman, Petr
2017-07-01
Occlusion of the left atrial appendage (LAA) has become an integral and important part of the surgical treatment of atrial fibrillation. Different methods of surgical occlusion of the LAA have been associated with varying levels of short- and long-term success for closure. The purpose of this study was to evaluate long-term results of epicardial placement and endocardial occlusion in patients undergoing cardiac operative procedures. A total of 101 patients (average age 65.7 years) undergoing cardiac operative procedures with the epicardial AtriClip Exclusion System of the LAA were enrolled in the study. The AtriClip was placed via a sternotomy or a thoracotomy or from a thoracoscopic approach. Postoperative variables, such as thromboembolic events, clip stability and endocardial leakage around the device, were examined by transoesophageal echocardiography (TEE) and/or computed tomography. Perioperative clip implantation was achieved in 98% of patients. TEE and/or computed tomography conducted during the follow-up period, comprising 1873 patient-months with a mean duration of 18 ± 11 months, revealed no clip migration, no leakage around the device and no clot formation near the remnant cul-de-sac. During the follow-up period, 4 of the cardiac patients experienced transitory ischaemic attacks, whereas no patient experienced a cerebrovascular attack. The Epicardial AtriClip Exclusion System of the LAA appears to be a feasable and safe operative method with a high success rate. Long-term follow-up confirmed clip stability, complete occlussion of the LAA and absence of any atrial fibrilation-related thromboembolic events. These results need to be confirmed by a larger, multicentre study. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
De Ambrogi, Marco; Ballester, Juan; Saravia, Fernando; Caballero, Ignacio; Johannisson, Anders; Wallgren, Margareta; Andersson, Magnus; Rodriguez-Martinez, Heriberto
2006-10-01
For artificial insemination (AI) in pigs, preservation of liquid boar semen at 16-20 degrees C is still common practice as sperm cryopreservation remains suboptimal in this species. To meet the different needs of the swine industry, several extenders have been developed to preserve semen in liquid form for short--and long-term storage. In the present study, three different commercial extenders devised for short-term (BTS+) or long-term preservation (MR-A and X-Cell), were used to test whether storage of semen from four mature, fertile boars at 17 degrees C for 96 h would affect sperm characteristics relevant for fertility, such as motility, membrane integrity and chromatin stability. Computer-assisted sperm analysis, and stainings with the acylated membrane dye SYBR-14/propidium iodide, and acridine orange in connection with flow cytometry were used to evaluate these variables. Percentages of total motile spermatozoa decreased slightly, but significantly, after 72-96 h. While membrane integrity values varied during the period of study, no significant changes in either membrane integrity or chromatin stability were, however, registered. This suggests a customary 96-day storage at 17 degrees C in these extenders was too short an interval to cause losses of integrity in nuclear DNA in the boar population studied.
2015-01-01
Traditional chelator-based radio-labeled nanoparticles and positron emission tomography (PET) imaging are playing vital roles in the field of nano-oncology. However, their long-term in vivo integrity and potential mismatch of the biodistribution patterns between nanoparticles and radio-isotopes are two major concerns for this approach. Here, we present a chelator-free zirconium-89 (89Zr, t1/2 = 78.4 h) labeling of mesoporous silica nanoparticle (MSN) with significantly enhanced in vivo long-term (>20 days) stability. Successful radio-labeling and in vivo stability are demonstrated to be highly dependent on both the concentration and location of deprotonated silanol groups (−Si–O–) from two types of silica nanoparticles investigated. This work reports 89Zr-labeled MSN with a detailed labeling mechanism investigation and long-term stability study. With its attractive radio-stability and the simplicity of chelator-free radio-labeling, 89Zr-MSN offers a novel, simple, and accurate way for studying the in vivo long-term fate and PET image-guided drug delivery of MSN in the near future. PMID:26213260
Chen, Feng; Goel, Shreya; Valdovinos, Hector F; Luo, Haiming; Hernandez, Reinier; Barnhart, Todd E; Cai, Weibo
2015-08-25
Traditional chelator-based radio-labeled nanoparticles and positron emission tomography (PET) imaging are playing vital roles in the field of nano-oncology. However, their long-term in vivo integrity and potential mismatch of the biodistribution patterns between nanoparticles and radio-isotopes are two major concerns for this approach. Here, we present a chelator-free zirconium-89 ((89)Zr, t1/2 = 78.4 h) labeling of mesoporous silica nanoparticle (MSN) with significantly enhanced in vivo long-term (>20 days) stability. Successful radio-labeling and in vivo stability are demonstrated to be highly dependent on both the concentration and location of deprotonated silanol groups (-Si-O(-)) from two types of silica nanoparticles investigated. This work reports (89)Zr-labeled MSN with a detailed labeling mechanism investigation and long-term stability study. With its attractive radio-stability and the simplicity of chelator-free radio-labeling, (89)Zr-MSN offers a novel, simple, and accurate way for studying the in vivo long-term fate and PET image-guided drug delivery of MSN in the near future.
Statistical evaluation of stability data: criteria for change-over-time and data variability.
Bar, Raphael
2003-01-01
In a recently issued ICH Q1E guidance on evaluation of stability data of drug substances and products, the need to perform a statistical extrapolation of a shelf-life of a drug product or a retest period for a drug substance is based heavily on whether data exhibit a change-over-time and/or variability. However, this document suggests neither measures nor acceptance criteria of these two parameters. This paper demonstrates a useful application of simple statistical parameters for determining whether sets of stability data from either accelerated or long-term storage programs exhibit a change-over-time and/or variability. These parameters are all derived from a simple linear regression analysis first performed on the stability data. The p-value of the slope of the regression line is taken as a measure for change-over-time, and a value of 0.25 is suggested as a limit to insignificant change of the quantitative stability attributes monitored. The minimal process capability index, Cpk, calculated from the standard deviation of the regression line, is suggested as a measure for variability with a value of 2.5 as a limit for an insignificant variability. The usefulness of the above two parameters, p-value and Cpk, was demonstrated on stability data of a refrigerated drug product and on pooled data of three batches of a drug substance. In both cases, the determined parameters allowed characterization of the data in terms of change-over-time and variability. Consequently, complete evaluation of the stability data could be pursued according to the ICH guidance. It is believed that the application of the above two parameters with their acceptance criteria will allow a more unified evaluation of stability data.
Stability of Chronic Hepatitis-Related Parameters in Serum Samples After Long-Term Storage.
Yu, Rentao; Dan, Yunjie; Xiang, Xiaomei; Zhou, Yi; Kuang, Xuemei; Yang, Ge; Tang, Yulan; Liu, Mingdong; Kong, Weilong; Tan, Wenting; Deng, Guohong
2017-06-01
Serum samples are widely used in clinical research, but a comprehensive research of the stability of parameters relevant to chronic hepatitis and the effect of a relatively long-term (up to 10 years) storage on the stability have rarely been studied. To investigate the stability of chronic hepatitis-related parameters in serum samples after long-term storage. The storage stability of common clinical parameters such as total bile acid (TBA), total bilirubin (TBIL), potassium, cholesterol, and protein parameters such as alanine aminotransferase (ALT), creatine kinase (CK), γ-glutamyltransferase (GGT), albumin, high-density lipoprotein (HDL) and also hepatitis B virus (HBV) DNA, hepatitis C virus (HCV) RNA, hepatitis B surface antigen (HBsAg), and chemokine (C-X-C motif) ligand 10 (CXCL10) were tested in serum samples after storing at -20°C or -70°C for 1, 2, 3, 7, 8, and 10 years. Levels of TBA, TBIL, and protein parameters such as ALT, CK, GGT, HDL, and HBsAg decreased significantly, but levels of potassium and cholesterol increased significantly after long-term storage, whereas blood glucose and triglycerides were stable during storage. HBV DNA remained stable at -70°C but changed at -20°C, whereas HCV RNA was stable after 1-, 2-, and 3-year storage. CXCL10 was still detectable after 8-year storage. Low temperatures (-70°C/80°C) are necessary for storage of serum samples in chronic hepatitis B research after long-term storage.
Piecha, Magdalena; Juras, Grzegorz; Król, Piotr; Sobota, Grzegorz; Polak, Anna; Bacik, Bogdan
2014-01-01
The study aimed to establish the short-term and long-term effects of whole-body vibration on postural stability. The sample consisted of 28 male subjects randomly allocated to four comparative groups, three of which exercised on a vibration platform with parameters set individually for the groups. The stabilographic signal was recorded before the test commenced, after a single session of whole-body vibration, immediately after the last set of exercises of the 4-week whole-body vibration training, and one week after the training ended. The subjects were exposed to vibrations 3 times a week for 4 weeks. Long-term vibration training significantly shortened the rambling and trembling paths in the frontal plane. The path lengths were significantly reduced in the frontal plane one week after the training end date. Most changes in the values of the center of pressure (COP) path lengths in the sagittal and frontal plane were statistically insignificant. We concluded that long-term vibration training improves the postural stability of young healthy individuals in the frontal plane. PMID:24520362
Evaluation of Surface Flux Parameterizations with Long-Term ARM Observations
Liu, Gang; Liu, Yangang; Endo, Satoshi
2013-02-01
Surface momentum, sensible heat, and latent heat fluxes are critical for atmospheric processes such as clouds and precipitation, and are parameterized in a variety of models ranging from cloud-resolving models to large-scale weather and climate models. However, direct evaluation of the parameterization schemes for these surface fluxes is rare due to limited observations. This study takes advantage of the long-term observations of surface fluxes collected at the Southern Great Plains site by the Department of Energy Atmospheric Radiation Measurement program to evaluate the six surface flux parameterization schemes commonly used in the Weather Research and Forecasting (WRF) model and threemore » U.S. general circulation models (GCMs). The unprecedented 7-yr-long measurements by the eddy correlation (EC) and energy balance Bowen ratio (EBBR) methods permit statistical evaluation of all six parameterizations under a variety of stability conditions, diurnal cycles, and seasonal variations. The statistical analyses show that the momentum flux parameterization agrees best with the EC observations, followed by latent heat flux, sensible heat flux, and evaporation ratio/Bowen ratio. The overall performance of the parameterizations depends on atmospheric stability, being best under neutral stratification and deteriorating toward both more stable and more unstable conditions. Further diagnostic analysis reveals that in addition to the parameterization schemes themselves, the discrepancies between observed and parameterized sensible and latent heat fluxes may stem from inadequate use of input variables such as surface temperature, moisture availability, and roughness length. The results demonstrate the need for improving the land surface models and measurements of surface properties, which would permit the evaluation of full land surface models.« less
Evaluation on Radiometric Capability of Chinese Optical Satellite Sensors
Yang, Aixia; Zhong, Bo; Wu, Shanlong; Liu, Qinhuo
2017-01-01
The radiometric capability of on-orbit sensors should be updated on time due to changes induced by space environmental factors and instrument aging. Some sensors, such as Moderate Resolution Imaging Spectroradiometer (MODIS), have onboard calibrators, which enable real-time calibration. However, most Chinese remote sensing satellite sensors lack onboard calibrators. Their radiometric calibrations have been updated once a year based on a vicarious calibration procedure, which has affected the applications of the data. Therefore, a full evaluation of the sensors’ radiometric capabilities is essential before quantitative applications can be made. In this study, a comprehensive procedure for evaluating the radiometric capability of several Chinese optical satellite sensors is proposed. In this procedure, long-term radiometric stability and radiometric accuracy are the two major indicators for radiometric evaluation. The radiometric temporal stability is analyzed by the tendency of long-term top-of-atmosphere (TOA) reflectance variation; the radiometric accuracy is determined by comparison with the TOA reflectance from MODIS after spectrally matching. Three Chinese sensors including the Charge-Coupled Device (CCD) camera onboard Huan Jing 1 satellite (HJ-1), as well as the Visible and Infrared Radiometer (VIRR) and Medium-Resolution Spectral Imager (MERSI) onboard the Feng Yun 3 satellite (FY-3) are evaluated in reflective bands based on this procedure. The results are reasonable, and thus can provide reliable reference for the sensors’ application, and as such will promote the development of Chinese satellite data. PMID:28117745
Evaluation on Radiometric Capability of Chinese Optical Satellite Sensors.
Yang, Aixia; Zhong, Bo; Wu, Shanlong; Liu, Qinhuo
2017-01-22
The radiometric capability of on-orbit sensors should be updated on time due to changes induced by space environmental factors and instrument aging. Some sensors, such as Moderate Resolution Imaging Spectroradiometer (MODIS), have onboard calibrators, which enable real-time calibration. However, most Chinese remote sensing satellite sensors lack onboard calibrators. Their radiometric calibrations have been updated once a year based on a vicarious calibration procedure, which has affected the applications of the data. Therefore, a full evaluation of the sensors' radiometric capabilities is essential before quantitative applications can be made. In this study, a comprehensive procedure for evaluating the radiometric capability of several Chinese optical satellite sensors is proposed. In this procedure, long-term radiometric stability and radiometric accuracy are the two major indicators for radiometric evaluation. The radiometric temporal stability is analyzed by the tendency of long-term top-of-atmosphere (TOA) reflectance variation; the radiometric accuracy is determined by comparison with the TOA reflectance from MODIS after spectrally matching. Three Chinese sensors including the Charge-Coupled Device (CCD) camera onboard Huan Jing 1 satellite (HJ-1), as well as the Visible and Infrared Radiometer (VIRR) and Medium-Resolution Spectral Imager (MERSI) onboard the Feng Yun 3 satellite (FY-3) are evaluated in reflective bands based on this procedure. The results are reasonable, and thus can provide reliable reference for the sensors' application, and as such will promote the development of Chinese satellite data.
Park, Sejoon; Son, Chung Woo; Lee, Sungho; Kim, Dong Young; Park, Cheolmin; Eom, Kwang Sup; Fuller, Thomas F; Joh, Han-Ik; Jo, Seong Mu
2016-11-11
Li-ion battery, separator, multicoreshell structure, thermal stability, long-term stability. A nanofibrous membrane with multiple cores of polyimide (PI) in the shell of polyvinylidene fluoride (PVdF) was prepared using a facile one-pot electrospinning technique with a single nozzle. Unique multicore-shell (MCS) structure of the electrospun composite fibers was obtained, which resulted from electrospinning a phase-separated polymer composite solution. Multiple PI core fibrils with high molecular orientation were well-embedded across the cross-section and contributed remarkable thermal stabilities to the MCS membrane. Thus, no outbreaks were found in its dimension and ionic resistance up to 200 and 250 °C, respectively. Moreover, the MCS membrane (at ~200 °C), as a lithium ion battery (LIB) separator, showed superior thermal and electrochemical stabilities compared with a widely used commercial separator (~120 °C). The average capacity decay rate of LIB for 500 cycles was calculated to be approximately 0.030 mAh/g/cycle. This value demonstrated exceptional long-term stability compared with commercial LIBs and with two other types (single core-shell and co-electrospun separators incorporating with functionalized TiO 2 ) of PI/PVdF composite separators. The proper architecture and synergy effects of multiple PI nanofibrils as a thermally stable polymer in the PVdF shell as electrolyte compatible polymers are responsible for the superior thermal performance and long-term stability of the LIB.
Park, Sejoon; Son, Chung Woo; Lee, Sungho; Kim, Dong Young; Park, Cheolmin; Eom, Kwang Sup; Fuller, Thomas F.; Joh, Han-Ik; Jo, Seong Mu
2016-01-01
Li-ion battery, separator, multicoreshell structure, thermal stability, long-term stability. A nanofibrous membrane with multiple cores of polyimide (PI) in the shell of polyvinylidene fluoride (PVdF) was prepared using a facile one-pot electrospinning technique with a single nozzle. Unique multicore-shell (MCS) structure of the electrospun composite fibers was obtained, which resulted from electrospinning a phase-separated polymer composite solution. Multiple PI core fibrils with high molecular orientation were well-embedded across the cross-section and contributed remarkable thermal stabilities to the MCS membrane. Thus, no outbreaks were found in its dimension and ionic resistance up to 200 and 250 °C, respectively. Moreover, the MCS membrane (at ~200 °C), as a lithium ion battery (LIB) separator, showed superior thermal and electrochemical stabilities compared with a widely used commercial separator (~120 °C). The average capacity decay rate of LIB for 500 cycles was calculated to be approximately 0.030 mAh/g/cycle. This value demonstrated exceptional long-term stability compared with commercial LIBs and with two other types (single core-shell and co-electrospun separators incorporating with functionalized TiO2) of PI/PVdF composite separators. The proper architecture and synergy effects of multiple PI nanofibrils as a thermally stable polymer in the PVdF shell as electrolyte compatible polymers are responsible for the superior thermal performance and long-term stability of the LIB. PMID:27833132
Angal, A.; Chander, Gyanesh; Choi, Taeyoung; Wu, Aisheng; Xiong, Xiaoxiong
2010-01-01
The Sonoran Desert is a large, flat, pseudo-invariant site near the United States-Mexico border. It is one of the largest and hottest deserts in North America, with an area of 311,000 square km. This site is particularly suitable for calibration purposes because of its high spatial and spectral uniformity and reasonable temporal stability. This study uses measurements from four different sensors, Terra Moderate Resolution Imaging Spectroradiometer (MODIS), Landsat 7 (L7) Enhanced Thematic Mapper Plus (ETM+), Aqua MODIS, and Landsat 5 (L5) Thematic Mapper (TM), to assess the suitability of this site for long-term stability monitoring and to evaluate the “radiometric calibration differences” between spectrally matching bands of all four sensors. In general, the drift in the top-of-atmosphere (TOA) reflectance of each sensor over a span of nine years is within the specified calibration uncertainties. Monthly precipitation measurements of the Sonoran Desert region were obtained from the Global Historical Climatology Network (GHCN), and their effects on the retrieved TOA reflectances were evaluated. To account for the combined uncertainties in the TOA reflectance due to the surface and atmospheric Bi-directional Reflectance Distribution Function (BRDF), a semi-empirical BRDF model has been adopted to monitor and reduce the impact of illumination geometry differences on the retrieved TOA reflectances. To evaluate calibration differences between the MODIS and Landsat sensors, correction for spectral response differences using a hyperspectral sensor is also demonstrated.
ERIC Educational Resources Information Center
Adorno, Dominique Persano; Pizzolato, Nicola; Fazio, Claudio
2018-01-01
This paper investigates the efficacy of an open-inquiry approach to achieve a long term stability of physics instruction. This study represents the natural continuation of a research project started four years ago when a sample of thirty engineering undergraduates, having already attended traditional university physics instruction, were involved…
NASA Astrophysics Data System (ADS)
Huang, Diyun; Parker, Timothy; Guan, Hann Wen; Cong, Shuxin; Jin, Danliang; Dinu, Raluca; Chen, Baoquan; Tolstedt, Don; Wolf, Nick; Condon, Stephen
2005-01-01
The electro-optic coefficient and long-term dipole alignment stability are two major factors in the development of high performance NLO materials for the application of high-speed EO devices. We have developed a high performance non-linear organic chromophore and incorporated it into a crosslinkable side-chain polyimide system. The polymer was synthesized through stepwise grafting of the crosslinker followed by the chromophore onto the polyimide backbone via esterification. Different chromophore loading levels were achieved by adjusting the crosslinker/chromophore feeding ratio. The polyimides films were contact-poled with second-harmonic generation monitoring. A large EO coefficient value was obtained and good long-term thermal stability at 85°C was observed.
ERIC Educational Resources Information Center
Walker, Elaine; And Others
1984-01-01
Asked preschool teachers (N=100) to rate severity, long-term outcome, stability, and importance of constitutional and environmental determinants for case vignettes describing three syndromes: aggression, hyperactivity, and withdrawal, and to judge the need for referral. Results indicated little evidence of sex bias in teachers' evaluations of the…
The Microstructural Evolution of Haynes 282 Alloy During Long-Term Exposure Tests
NASA Astrophysics Data System (ADS)
Fu, Rui; Zhao, Shuangqun; Wang, Yanfeng; Li, Qiang; Ma, Yunhai; Lin, Fusheng; Chi, Chengyu
Haynes 282 alloy is a γ' precipitation strengthened nickel based superalloy designed by Haynes International Incorporation in 2005. This alloy is currently being evaluated for use as high temperature components at 700°C Advanced-Ultra Supercritical (A-USC)power plants, thus it is particularly important to have good creep property and microstructure stability.
Wang, Xin; Zhang, Jingdong; Wang, Linling; Chen, Jing; Hou, Huijie; Yang, Jiakuan; Lu, Xiaohua
2017-01-05
In this study, the long-term stability of Cr(VI) in the FeSO 4 and H 2 SO 4 (FeSO 4 -H 2 SO 4 ) treated chromite ore processing residue (COPR) after 400 curing days and the stabilization mechanisms were investigated. FeSO 4 -H 2 SO 4 treatment significantly reduced toxicity characteristic leaching procedure (TCLP) and synthetic precipitation leaching procedure (SPLP) Cr(VI) concentrations to lower than the regulatory limit of 1.5mgL -1 (HJ/T 301-2007, China EPA) even for the samples curing 400days, achieving an outstanding long-term stability. Our independent leaching tests revealed that H + and SO 4 2- have synergistic effect on promoting the release of Cr(VI), which would make Cr(VI) easier accessed by Fe(II) during stabilization. The contributions of H + and SO 4 2- to Cr(VI) release ratio were 25%-44% and 19%-38%, respectively, as 5mol H 2 SO 4 per kg COPR was used. X-ray powder diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and alkaline digestion analyses were also employed to interpret the possible stabilization mechanism. Cr(VI) released from COPR solid was reduced to Cr(III) by Fe(II), and then formed stable Fe x Cr (1-x) (OH) 3 precipitate. This study provides a facile and reliable scheme for COPR stabilization, and verifies the excellent long-term stability of the FeSO 4 -H 2 SO 4 treated COPR. Copyright © 2016 Elsevier B.V. All rights reserved.
De Palma, Angela; Sollitto, Francesco; Loizzi, Domenico; Di Gennaro, Francesco; Scarascia, Daniele; Carlucci, Annalisa; Giudice, Giuseppe; Armenio, Andrea; Ludovico, Rossana; Loizzi, Michele
2016-03-01
We report short and long-term results with the dedicated Synthes(®) titanium plates system, introduced 5 years ago, for chest wall stabilization and reconstruction. We retrospectively analyzed (January 2010 to December 2014) 27 consecutive patients (22 males, 5 females; range 16-83 years, median age 60 years), treated with this system: primary [3] and secondary [8] chest wall tumor; flail chest [5]; multiple ribs fractures [5]; sternal dehiscence-diastasis [3]; sternal fracture [1]; sternoclavicular joint dislocation [1]; Poland syndrome [1]. Short-term results were evaluated as: operating time, post-operative morbidity, mortality, hospital stay; long-term results as: survival, plates-related morbidity, spirometric values, chest pain [measured with Verbal Rating Scale (VRS) and SF12 standard V1 questionnaire]. Each patient received from 1 to 10 (median 2) titanium plates/splints; median operating time was 150 min (range: 115-430 min). Post-operative course: 15 patients (55.6%) uneventful, 10 (37%) minor complications, 2 (7.4%) major complications; no post-operative mortality. Median post-operative hospital stay was 13 days (range: 5-129 days). At a median follow-up of 20 months (range: 1-59 months), 21 patients (78%) were alive, 6 (22%) died. Three patients presented long-term plates-related morbidity: plates rupture [2], pin plate dislodgment [1]; two required a second surgical look. One-year from surgery median spirometric values were: FVC 3.31 L (90%), FEV1 2.46 L (78%), DLCO 20.9 mL/mmHg/min (76%). On 21 alive patients, 7 (33.3%) reported no pain (VRS score 0), 10 (47.6%) mild (score 2), 4 (19.1%) moderate (score 4), no-one severe (score >4); 15 (71.5%) reported none or mild, 6 (28.5%) moderate pain influencing quality of life. An optimal chest wall stabilization and reconstruction was achieved with the Synthes(®) titanium plates system, with minimal morbidity, no post-operative mortality, acceptable operating time and post-operative hospital stay. Long-term restoration of a normal respiratory function was achieved, with minimal plates-related morbidity and chest pain.
Karabıçak, Nilgün; Karatuna, Onur; Akyar, Işın
2016-06-01
Serious mycological work requires a reliable source of cultures that are maintained under safe long-term storage. In this study, 1186 clinical fungal isolates consisting of molds (20 species in 11 genera) and yeasts (21 species in seven genera) maintained in water, under mineral oil at room temperature and cryopreserved at -80 °C for periods ranging from 1 to 12 years, were evaluated for their viabilities and stabilities. The strains were subcultured onto either Sabouraud dextrose agar or potato dextrose agar to determine the viabilities and purities. The stabilities of the dermatophytes were investigated using urease test medium, the Trichophyton agar test and morphological examination. The stabilities of yeasts were evaluated by microscopic morphology and by determining the antifungal susceptibilities of random samples of yeasts (n = 120). Additionally, 365 strains (dermatophytes, n = 115; yeasts, n = 250) were further characterized by "matrix-assisted laser desorption/ionization time-of-flight mass spectrometry." After 12 years of preservation, the survival rates with the three different preservation techniques, i.e., in water, under mineral oil and by freezing, were assessed as 94.7, 82.0 and 97.4 %, respectively. Viability was generally unrelated to the duration of storage. More stable and consistent growth was achieved after storage in water and freezing compared with mineral oil preservation. Our results demonstrate that the procedure for maintaining fungal cultures in water is a simple and inexpensive method, next to cryopreservation, and that both can be reliably used for the long-term preservation of most fungal isolates.
Yu, Tae Jun; Hong, Kyung-Han; Choi, Hyun-Gyug; Sung, Jae Hee; Choi, Il Woo; Ko, Do-Kyeong; Lee, Jongmin; Kim, Junwon; Kim, Dong Eon; Nam, Chang Hee
2007-06-25
We demonstrate a long-term operation with reduced phase noise in the carrier-envelope-phase (CEP) stabilization process by employing a double feedback loop and an improved signal detection in the direct locking technique [Opt. Express 13, 2969 (2005)]. A homodyne balanced detection method is employed for efficiently suppressing the dc noise in the f-2f beat signal, which is converted into the CEP noise in the direct locking loop working at around zero carrier-envelope offset frequency (f(ceo)). In order to enhance the long-term stability, we have used the double feedback scheme that modulates both the oscillator pump power for a fast control and the intracavity-prism insertion depth for a slow and high-dynamic-range control. As a result, the in-loop phase jitter is reduced from 50 mrad of the previous result to 29 mrad, corresponding to 13 as in time scale, and the long-term stable operation is achieved for more than 12 hours.
Evaluation of accelerated stability test conditions for medicated chewing gums.
Maggi, Lauretta; Conte, Ubaldo; Nhamias, Alain; Grenier, Pascal; Vergnault, Guy
2013-10-01
The overall stability of medicated chewing gums is investigated under different storage conditions. Active substances with different chemical stabilities in solid state are chosen as model drugs. The dosage form is a three layer tablet obtained by direct compression. The gum core contains the active ingredient while the external layers are formulated to prevent gum adhesion to the punches of the tableting machine. Two accelerated test conditions (40°C/75% RH and 30°C/65% RH) are performed for 6 months. Furthermore, a long-term stability test at room conditions is conducted to verify the predictability of the results obtained from the stress tests. Some drugs are stable in all the conditions tested, but other drugs, generally considered stable in solid dosage forms, have shown relevant stability problems particularly when stress test conditions are applied to this particular semi-solid dosage forms. For less stable drugs, the stress conditions of 40°C/75% RH are not always predictable of chewing gum stability at room temperature and may produce false negative; intermediate conditions, 30°C/65% RH, are more predictive for this purpose, the results of drug content found after 6 months at intermediate stress conditions and 12 months at room conditions are generally comparable. But the results obtained show that only long-term conditions stability tests gave consistent results. During aging, the semi solid nature of the gum base itself, may also influence the drug delivery rate during chewing and great attention should be given also to the dissolution stability.
Dell’Osso, Bernardo; Buoli, Massimiliano; Riundi, Riccardo; D’Urso, Nazario; Pozzoli, Sara; Bassetti, Roberta; Mundo, Emanuela; Altamura, A Carlo
2009-01-01
Introduction Bipolar disorder (BD) is a prevalent, comorbid, and impairing condition. Potential predictors of response to pharmacological treatment are object of continuous investigation in patients with BD. The present naturalistic study was aimed to assess clinical features and long-term response to mood stabilizers in a sample of bipolar subjects with different ages at onset. Methods The study sample included 108 euthymic patients, diagnosed as affected by BD, either type I or II, according to the DSM-IV-TR, who were started on mood stabilizer treatment. Patients were followed-up for 24 months and the occurrence of any mood episode collected. At the end of the follow-up, patients were divided in 3 subgroups according to the age at onset (early-onset ≤30 years, middle-onset >30–≤45 years, and late-onset >45 years, respectively) and the long-term response to mood stabilizers was compared between them along with other clinical features. Results The three subgroups showed significant differences in terms of clinical and demographic features and, with respect to long-term response to mood stabilizers, the early-onset subgroup showed a better outcome in terms of reduction of major depressive episodes during the 24-month follow-up compared to the other subgroups (one way ANOVA, F = 3.57, p = 0.032). Conclusions Even though further controlled studies are needed to clarify the relationship between age at onset and outcome in BD, the present follow-up study suggests clinical peculiarities and different patterns of response to mood stabilizers across distinct subgroups of patients with BD and different ages at onset. PMID:19649214
Azarbad, Hamed; van Gestel, Cornelis A. M.; Niklińska, Maria; Laskowski, Ryszard; Röling, Wilfred F. M.; van Straalen, Nico M.
2016-01-01
Many microbial ecology studies have demonstrated profound changes in community composition caused by environmental pollution, as well as adaptation processes allowing survival of microbes in polluted ecosystems. Soil microbial communities in polluted areas with a long-term history of contamination have been shown to maintain their function by developing metal-tolerance mechanisms. In the present work, we review recent experiments, with specific emphasis on studies that have been conducted in polluted areas with a long-term history of contamination that also applied DNA-based approaches. We evaluate how the “costs” of adaptation to metals affect the responses of metal-tolerant communities to other stress factors (“stress-on-stress”). We discuss recent studies on the stability of microbial communities, in terms of resistance and resilience to additional stressors, focusing on metal pollution as the initial stress, and discuss possible factors influencing the functional and structural stability of microbial communities towards secondary stressors. There is increasing evidence that the history of environmental conditions and disturbance regimes play central roles in responses of microbial communities towards secondary stressors. PMID:27314330
LONG TERM STABILITY STUDY AT FNAL AND SLAC USING BINP DEVELOPED HYDROSTATIC LEVEL SYSTEM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seryi, Andrei
2003-05-28
Long term ground stability is essential for achieving the performance goals of the Next Linear Collider. To characterize ground motion on relevant time scales, measurements have been performed at three geologically different locations using a hydrostatic level system developed specifically for these studies. Comparative results from the different sites are presented in this paper.
Oliveira, Dauro Douglas; de Oliveira, Bruno Franco; Figueiredo, Daniel Santos Fonseca; Antunes, Alberto Nogueira da Gama; Seraidarian, Paulo Isaías
2017-10-01
This article reports the camouflage retreatment of an adult patient presenting an asymmetric Class III malocclusion and posterior open bite. Sliding jigs (SJs) associated with intermaxillary elastics were used. The long-term stability of the excellent results suggests that the use of SJs to correct asymmetric posterior occlusions may be effective.
Espinosa, Gerard; Simeón, Carmen Pilar; Plasín, Miguel Ángel; Xaubet, Antoni; Muñoz, Xavier; Fonollosa, Vicent; Cervera, Ricard; Vilardell, Miquel
2011-05-01
Cyclophosphamide (CYC) stabilizes the parameters of lung function tests (LFT) of patients with (SSc) and interstitial lung disease (ILD) treated for 12 months. There is little information about long-term treatment (24 months). The aim of this study is to analyze the effect of intravenous CYC in LFT parameters in patients with SSc and ILD treated for 24 months. Retrospective study of 37 patients with ILD associated with scleroderma treated with intravenous CYC for 24 months and regularly assessed by LFT (at baseline, 6, 12 and 24 months) including forced vital capacity (FVC) and transfer capacity of carbon monoxide (DL(CO)). To evaluate response to treatment the recommendations of the ATS and SEPAR were considered. The difference between FVC and DL(CO) values performed at baseline and those performed at 6, 12, and 24 months were less than 10%, which meant that CYC stabilized LFT. There were no differences in LFT when patients treated for 6 months were evaluated according to the type of skin involvement of the SSc (diffuse or limited) and the duration of the ILD. Although patients with severe restriction (FVC<70%) showed more improvement, it was less than 10% in all cases. In this series of patients with ILD associated with SSc intravenous CYC was effective in stabilizing LFT in long-term treatment. Copyright © 2010 SEPAR. Published by Elsevier Espana. All rights reserved.
Tsai, Chia-Jui; Cheng, Chin; Chou, Po-Han; Lin, Ching-Heng; McInnis, Melvin G; Chang, Chia-Li; Lan, Tsuo-Hung
2016-05-15
The suicide rate is high among bipolar disorder (BD) patients. Previous studies have focused on the anti-suicidal effect of long-term treatment with mood stabilizers but less on the immediate preventive effects of interventions. The aim of the study was to evaluate the short-term and immediate anti-suicidal effects of mood stabilizers on recent-onset BD patients. The National Health Insurance Database (NHID) of Taiwan was used to perform a nationwide cohort observation study of suicide behaviors in bipolar disorder. All the recent-onset BD patients (ICD-9-CM code 296 except 296.2 and 296.3) diagnosed between 2000-2005 were collected (n=5091) and followed through 2009. The primary endpoint was the presence of a suicide code or the end of observation; exposure to mood stabilizers in the final month of observation was the independent variable. The hazard ratios (HRs) of suicide-related events, completed suicide, and all-cause mortality were significantly lower for those treated with lithium, divalproex, or carbamazepine compared with no use in the last month (HRs of suicide-related events were 0.10, 0.14 and 0.10, respectively, and all-cause mortality HRs were 0.03; P<0.0001); there was no significant difference in HR between the mood stabilizers. The NIHD does not provide information on the severity, mood status, or treatment adherence of BD patients. Neither substance-related disorder nor personality disorder were included in the analysis. We focused on the effect of the final prescription time period, not the long-term protective effect. The immediate recent use of any mood stabilizer significantly lowers the rate of death, suicide, or suicidal behavior in BD. Copyright © 2016 Elsevier B.V. All rights reserved.
Chorny, Michael; Levy, Daniel; Schumacher, Ilana; Lichaa, Chaim; Gruzman, Boris; Livshits, Oleg; Lomnicky, Yossi
2003-04-24
Benoxinate is a local anaesthetic used for ophthalmic applications. The aim of this study was to develop a rapid and simple stability-indicating method for the determination of benoxinate formulated for ophthalmic use, evaluate its long-term stability and identify its major degradation product. Benoxinate was eluted on a 10 microm Spherisorb phenyl column, 250 x 3.2 mm, with a mobile phase consisting of acetonitrile-buffer (pH 3.5) (35:65, v/v), pumped at 0.8 ml min(-1) flow rate. The buffer was composed of sodium dihydrogen phosphate (50 mM), sodium hydrogen sulfate (2.5 mM) and 1-heptanesulfonic acid sodium salt (5 mM). The analyte was quantified spectrophotometrically at 308 nm. The chromatograms of benoxinate formulations obtained by this method showed benoxinate (t = 4.5 min) well resolved from its degradation product (t = 2.3 min), which was separately identified by means of HPLC-MS as 4-amino-3-butoxybenzoic acid. The assay was demonstrated to have high accuracy, precision and linearity. The method was implemented in investigating the long-term stability of benoxinate 0.4% ophthalmic solutions. The method was found to be simple, quick and selective in determining benoxinate concentrations in fresh and aged preparations.
Choi, J H; Fukushi, K; Ng, H Y; Yamamoto, K
2006-01-01
Nanofiltration (NF) is considered as one of the most promising separation technologies to obtain a very good-quality permeate in water and wastewater treatment. A submerged NF membrane bioreactor (NF MBR) using polyamide membranes was tested for a long-term operation and the performance of the NF MBR was compared with that of a microfiltration MBR (MF MBR). Total organic carbon (TOC) concentration in the permeate of the NF MBR ranged from 0.5 to 2.0 mg/L, whereas that of the MF MBR showed an average of 5 mg/L. This could be explained by the tightness of the NF membrane. Although the concentration of organic matter in the supernatant of the NF MBR was higher than that in the permeate due to high rejection by the NF membrane, the NF MBR showed excellent treatment efficiency and satisfactory operational stability for a long-term operation.
Long Duration Life Test of Propylene Glycol Water Based Thermal Fluid Within Thermal Control Loop
NASA Technical Reports Server (NTRS)
Le, Hung; Hill, Charles; Stephan, Ryan A.
2010-01-01
Evaluations of thermal properties and resistance to microbial growth concluded that 50% Propylene Glycol (PG)-based fluid and 50% de-ionized water mixture was desirable for use as a fluid within a vehicle s thermal control loop. However, previous testing with a commercial mixture of PG and water containing phosphate corrosion inhibitors resulted in corrosion of aluminum within the test system and instability of the test fluid. This paper describes a follow-on long duration testing and analysis of 50% Propylene Glycol (PG)-based fluid and 50% de-ionized water mixture with inorganic corrosion inhibitors used in place of phosphates. The test evaluates the long-term fluid stability and resistance to microbial and chemical changes
Lou, Jerry J; Mirsadraei, Leili; Sanchez, Desiree E; Wilson, Ryan W; Shabihkhani, Maryam; Lucey, Gregory M; Wei, Bowen; Singer, Elyse J; Mareninov, Sergey; Yong, William H
2014-01-01
Frozen biospecimens are crucial for translational research and contain well preserved nucleic acids and protein. However, the risk for catastrophic freezer failure as well as space, cost, and environmental concerns argue for evaluating long-term room temperature storage alternatives. Formalin-fixed paraffin embedded (FFPE) tissues have great value but their use is limited by cross-linking and fragmentation of nucleic acids, as well as loss of enzymatic activity. Stabilization solutions can now robustly preserve fresh tissue for up to 7 days at room temperature. For longer term storage, commercial vendors of chemical matrices claim real time stability of nucleic acids of over 2 years and their accelerated aging studies to date suggest stability for 12 years for RNA and 60 years for DNA. However, anatomic pathology biorepositories store mostly frozen tissue rather than nucleic acids. Small quantities of tissue can be directly placed on some chemical matrices to stabilize DNA, however RNA and proteins are not preserved. Current lyophilization approaches can preserve histomorphology, DNA, RNA, and proteins though RNA shows moderate degradation after 1–2 years. Formalin free fixatives show improved but varying abilities to preserve nucleic acids and face validation as well as cost barriers in replacing FFPE specimens. The paraffin embedding process can degrade RNA. Development of robust long-term room temperature biospecimen tissue storage technology can potentially reduce costs for the biomedical community in the face of growing targeted therapy needs and decreasing budgets. PMID:24362270
New kind of injection-locked oscillator and its corresponding long-term stability control.
Hong, Jun; Liu, An; Wang, Xiao-hu; Yao, Sheng-xing; Li, Zu-ling
2015-09-20
A new type of opto-electronic hybrid oscillator is proposed for the first time, to the best of our knowledge, and verified by experiments in this paper. Typical electronic oscillator-dielectric resonator oscillator as the first injection source is used to injection lock the first long-fiber loop-based opto-electronic oscillator (OEO); then its output is used to injection lock the second long-fiber opto-electronic oscillator. Using this method, low-phase noise output signal can be obtained. Experiments show that single side-band (SSB) phase noise of a 9.5 GHz oscillation signal at 10 kHz offset frequency decreases from -123 to -135 dBc/Hz after the first injection, then, through the second injection, the SSB phase noise drops down to -146 dBc/Hz. In order to solve the long-term stability problem of the above oscillator, a new stability-control circuit also is designed and verified by experiments. Experiments show that the Allan deviation decreases from 9.0×10(-11) to 2.2×10(-12) during 1 s after the long-term stability-control circuit being used.
Long-term behaviors of phosphate-based rapid repairing material for concrete shafts in coal mines.
Lei, Feng; Zhen-Ya, Zhang; Xiao-Dong, Wen; Chao, Xin; Dong-Yuan, Hu
2018-04-01
Concrete structures in shaft linings are apt to deteriorate prematurely and therefore prompt restoration is required. In considering this, desulphurization fly ash and machine-made tuff sand are employed to fabricate a phosphate-based rapid repairing material. The long-term efficiency of the material is evaluated based on combined factors, so drying shrinkage, interfacial bonding strength, corrosion resistance, and combustibility of the specimens are tested and researched in this paper. Experimental results showed that, under a dry circumstance, the material goes through a minor expansion at an early stage. It goes into a stage of rapid contraction after one day and a stable contraction after seven days. After 28 days, the total deformation is 67 micro-strains. On the other hand, the fabricated material manifests an excellent mechanical property. The one hour bending strength and compressive strength were 9.2 MPa and 32.6 MPa, respectively. A long-term mine water flushing simulation demonstrates that only 10% bending strength is lost and the corrosion resistance coefficient stays above 0.8, so a very good corrosion resistance is thus achieved. What is more, this repairing material retains its stability even at a high temperature of 1000°C, revealing its good thermo-stability. All these prominent properties make it a good prospective material for real restoration applications.
Chen, Tao; Li, Qiang; Guo, Lina; Yu, Li; Li, Zhenyan; Guo, Huixin; Li, Haicheng; Zhao, Meigui; Chen, Liang; Chen, Xunxun; Zhong, Qiu; Zhou, Lin; Wu, Ting
2016-01-01
To overcome the undesirable side effects and reduce the cytotoxicity of isoniazid (INH) and rifampin (RMP) in the digestive tract, a poly(methacrylic acid) (PMAA) nanogel was developed as a carrier of INH and RMP. This PMAA/INH/RMP nanogel was prepared as a treatment for intestinal tuberculosis caused by multidrug-resistant Mycobacterium tuberculosis (MTB). The morphology, size, and in vitro release properties were evaluated in a simulated gastrointestinal medium, and long-term antibacterial performance, cytotoxicity, stability, and activity of this novel PMAA/INH/RMP nanogel against multidrug-resistant MTB in the intestine were investigated. Our results indicate that the PMAA/INH/RMP nanogel exhibited extended antibacterial activity by virtue of its long-term release of INH and RMP in the simulated gastrointestinal medium. Further, this PMAA/INH/RMP nanogel exhibited lower cytotoxicity than did INH or RMP alone, suggesting that this PMAA/INH/RMP nanogel could be a more useful dosage form than separate doses of INH and RMP for intestinal MTB. The novel aspects of this study include the cytotoxicity study and the three-phase release profile study, which might be useful for other researchers in this field. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.
Effects of long-term cryopreservation on peripheral blood progenitor cells.
Vosganian, Gregory S; Waalen, Jill; Kim, Kevin; Jhatakia, Sejal; Schram, Ethan; Lee, Tracey; Riddell, Dan; Mason, James R
2012-11-01
The long-term stability of cryopreserved peripheral blood progenitor cells is an important issue for patients experiencing disease relapse. However, there is no consensus on how to evaluate the long-term effects of cryopreservation. We describe the effect of cryopreservation on viability and progenitor colony activity from 87 individual samples processed at the Scripps Green Hospital Stem Cell Processing Center (La Jolla, CA, USA). We randomly selected 87 peripheral blood hematopoietic stem cell (PBHSC) samples from 60 patients and evaluated the effect of cryopreservation on sample viability and red and white cell colony activity after < 24 h and 7, 10 and 15 years of cryopreservation. Viability was assayed via trypan blue dye exclusion and activity was measured following 14 days of culture. An age at collection older than 50 years may result in suboptimal activity and viability following long-term cryopreservation, while gender and disease status had no effect. Cryopreservation did not significantly affect white or red cell activity following 10 years of cryopreservation. However, for samples stored longer than 10 years, viability and activity significantly decreased. We noted a positive association between higher pre-cryopreservation %CD34 count and colony activity. Cryopreservation of peripheral blood progenitor cells for up to 10 years results in no loss of clonogenic capacity, as determined by culture activity, although longer durations of storage may affect activity. Until validated methods are developed, cryopreserved grafts should be evaluated based on pre-freeze CD34(+) cell counts as assayed by flow cytometry, and post-thaw sample evaluation should be reserved for patients identified as poor mobilizers.
Wang, Lulu; Ma, Yingying; Gu, Yu; Liu, Yangyang; Zhao, Juan; Yan, Beibei; Wang, Yancai
2018-04-19
Freeze-drying is an effective way to improve long-term physical stability of nanosuspension in drug delivery applications. Nanosuspension also known as suspension of nanoparticles. In this study, the effect of freeze-drying with different cryoprotectants on the physicochemical characteristics of resveratrol (RSV) nanosuspension and quercetin (QUE) nanosuspension was evaluated. D-α-tocopheryl polyethylene glycol succinate (TPGS) and folate-modified distearoylphosphatidyl ethanolamine-polyethylene glycol (DSPE-PEG-FA) were selected as functional stabilisers formulated nanosuspension which were prepared by anti-solvent precipitation method. RSV nanoparticle size and QUE nanoparticle size were about 210 and 110 nm, respectively. The AFM and TEM results of nanosuspension showed uniform and irregular shape particles. After freeze-drying, the optimal concentration of four cryoprotectants was determined by the particle size of re-dispersed nanoparticles. The dissolution profile of drug nanoparticle significantly showed approximately at a 6-8-fold increase dissolution rate. Moreover, TPGS and DSPE-PEG-FA stabilised RSV nanosuspension and QUE nanosuspension samples showed better effect on long-term physical stability.
Chander, G.; Xiong, X.; Angal, A.; Choi, T.
2009-01-01
The Committee on Earth Observation Satellites (CEOS) Infrared and Visible Optical Sensors (IVOS) subgroup members established a set of CEOS-endorsed globally distributed reference standard test sites for the postlaunch calibration of space-based optical imaging sensors. This paper discusses the top five African pseudo-invariant sites (Libya 4, Mauritania 1/2, Algeria 3, Libya 1, and Algeria 5) that were identified by the IVOS subgroup. This paper focuses on monitoring the long-term radiometric stability of the Terra Moderate Resolution Imaging Spectroradiometer (MODIS) and the Landsat 7 (L7) Enhanced Thematic Mapper Plus (ETM+) sensors using near-simultaneous and cloud-free image pairs acquired from launch to December 2008 over the five African desert sites. Residual errors and coefficients of determination were also generated to support the quality assessment of the calibration differences between the two sensors. An effort was also made to evaluate the relative stability of these sites for long-term monitoring of the optical sensors. ??2009 IEEE.
Corrosion testing of candidates for the alkaline fuel cell cathode
NASA Technical Reports Server (NTRS)
Singer, Joseph; Fielder, William L.
1989-01-01
Current/voltage data was obtained for specially made corrosion electrodes of some oxides and of gold materials for the purpose of developing a screening test of catalysts and supports for use at the cathode of the alkaline fuel cell. The data consists of measurements of current at fixed potentials and cyclic voltammograms. These data will have to be correlated with longtime performance data in order to fully evaluate this approach to corrosion screening. Corrosion test screening of candidates for the oxygen reduction electrode of the alkaline fuel cell was applied to two substances, the pyrochlore Pb2Ru2O6.5 and the spinel NiCo2O4. The substrate gold screen and a sample of the IFC Orbiter Pt-Au performance electrode were included as blanks. The pyrochlore data indicate relative stability, although nothing yet can be said about long term stability. The spinel was plainly unstable. For this type of testing to be validated, comparisons will have to be made with long term performance tests.
Marzouk, Eiman S; Kassem, Hassan E
2018-03-01
To evaluate soft tissue changes and their long-term stability in skeletal anterior open bite adults treated by maxillary posterior teeth intrusion using zygomatic miniplates and premolar extractions. Lateral cephalograms of 26 patients were taken at pretreatment (T1), posttreatment (T2), 1 year posttreatment (T3), and 4 years posttreatment (T4). At the end of treatment, the soft tissue facial height and profile convexity were reduced. The lips increased in length and thickness, with backward movement of the upper lip and forward movement of the lower lip. The total relapse rate ranged from 20.2% to 31.1%. At 4 years posttreatment, 68.9% to 79.8% of the soft tissue treatment effects were stable. The changes in the first year posttreatment accounted for approximately 70% of the total relapse. Soft tissue changes following maxillary posterior teeth intrusion with zygomatic miniplates and premolar extractions appear to be stable 4 years after treatment.
Durability of aircraft composite materials
NASA Technical Reports Server (NTRS)
Dextern, H. B.
1982-01-01
Confidence in the long term durability of advanced composites is developed through a series of flight service programs. Service experience is obtained by installing secondary and primary composite components on commercial and military transport aircraft and helicopters. Included are spoilers, rudders, elevators, ailerons, fairings and wing boxes on transport aircraft and doors, fairings, tail rotors, vertical fins, and horizontal stabilizers on helicopters. Materials included in the evaluation are boron/epoxy, Kevlar/epoxy, graphite/epoxy and boron/aluminum. Inspection, maintenance, and repair results for the components in service are reported. The effects of long term exposure to laboratory, flight, and outdoor environmental conditions are reported for various composite materials. Included are effects of moisture absorption, ultraviolet radiation, and aircraft fuels and fluids.
Fleege, C; Rickert, M; Werner, I; Rauschmann, M; Arabmotlagh, M
2016-09-01
Determination of the extent of spinal fusion for lumbar degenerative diseases is often difficult due to minor pathologies in the adjacent segment. Although surgical intervention is required, fusion seems to be an overtreatment. Decompression alone may be not enough as this segment is affected by multiple factors such as destabilization, low grade degeneration and an unfavorable biomechanical transition next to a rigid construct. An alternative surgical treatment is a hybrid construct, consisting of fusion and implantation of an interlaminar stabilization device at the adjacent level. The aim of this study was to compare long-term clinical outcome after lumbar fusion with a hybrid construct including an interlaminar stabilization device as "topping-off". A retrospective analysis of 25 lumbar spinal fusions from 2003 to 2010 with additional interlaminar stabilization device was performed. Through a matched case controlled procedure 25 congruent patients who received lumbar spinal fusion in one or two levels were included as a control group. At an average follow-up of 43 months pre- and postoperative pain, ODI, SF-36 as well as clinical parameters, such as leg and back pain, walking distance and patient satisfaction were recorded. Pain relief, ODI improvement and patient satisfaction was significantly higher in the hybrid group compared to the control group. SF-36 scores improved in both groups but was higher in the hybrid group, although without significance. Evaluation of walking distance showed no significant differences. Many outcome parameters present significantly better long-term results in the hybrid group compared to sole spinal fusion. Therefore, in cases with a clear indication for lumbar spinal fusion with the need for decompression at the adjacent level due to spinal stenosis or moderate spondylarthrosis, support of this segment with an interlaminar stabilization device demonstrates a reasonable treatment option with good clinical outcome. Also, the length of the fusion construct can be reduced allowing for a softer and more harmonic transition.
Stability studies of amphetamine and ephedrine derivatives in urine.
Jiménez, C; de la Torre, R; Ventura, M; Segura, J; Ventura, R
2006-10-20
Knowledge of the stability of drugs in biological specimens is a critical consideration for the interpretation of analytical results. Identification of proper storage conditions has been a matter of concern for most toxicology laboratories (both clinical and forensic), and the stability of drugs of abuse has been extensively studied. This concern should be extended to other areas of analytical chemistry like antidoping control. In this work, the stability of ephedrine derivatives (ephedrine, norephedrine, methylephedrine, pseudoephedrine, and norpseudoephedrine), and amphetamine derivatives (amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), and 3,4-methylenedioxymethamphetamine (MDMA)) in urine has been studied. Spiked urine samples were prepared for stability testing. Urine samples were quantified by GC/NPD or GC/MS. The homogeneity of each batch of sample was verified before starting the stability study. The stability of analytes was evaluated in sterilized and non-sterilized urine samples at different storage conditions. For long-term stability testing, analyte concentration in urine stored at 4 degrees C and -20 degrees C was determined at different time intervals for 24 months for sterile urine samples, and for 6 months for non-sterile samples. For short-term stability testing, analyte concentration was evaluated in liquid urine stored at 37 degrees C for 7 days. The effect of repeated freezing (at -20 degrees C) and thawing (at room temperature) was also studied in sterile urine for up to three cycles. No significant loss of the analytes under study was observed at any of the investigated conditions. These results show the feasibility of preparing reference materials containing ephedrine and amphetamine derivatives to be used for quality control purposes.
Upgrade of BPM Electronics for the SPring-8 Storage Ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sasaki, Shigeki; Fujita, Takahiro; Shoji, Masazumi
2006-11-20
SPring-8, a 3rd generation synchrotron light source, has operated since 1997. Improvement of BPM performance is required as a part of upgrading activities of the storage ring as a light source. We have developed new electronics circuits for signal processing of the storage ring BPM, with target performance of sub-{mu}m range resolution with sufficiently fast measurement speed and good long-term stability. A set of the new circuits consists of multiplexers, an RF amplifier, a mixer, an IF amplifier, and a local oscillator for analog signal processing. The IF amplifier outputs are sampled with 16-bit 2-MSPS ADC on ADC boards andmore » the data are sent to a DSP board. The sampled data are processed and converted to position information in the DSP. A multiplexing method was employed to have a better stability of the performance by cancellation of variation common to each channel. Evaluation of the performance by using a prototype shows that position resolution well into the sub-{mu}m range has been achieved with a bandwidth of 1 kHz, and long-term stability of within 1 {mu}m has also been achieved.« less
Large variability of biochar stability and biochar properties
NASA Astrophysics Data System (ADS)
Lehmann, J.; Nguyen, B.; Hanley, K.; Enders, A.
2008-12-01
In general, charring or purposeful pyrolysis increases the stability of biomass. It is less clear, however, to what extent biochar properties influence its stability. Chemical and physical properties of biochars and biomass-derived black carbons (BC) vary greatly as a function of the type of biomass it was generated from and of the production temperature. We show that these properties greatly affect the stability of BC is a function of both these factors, with highly significant interactions. BC produced from corn stalks produced at 350°C decomposed much quicker when incubated at field capacity at 30°C for one year than those produced at 600°C. In contrast, there was hardly a difference noted between those two temperatures if oak was the precursor biomass. Such differences in labile carbon not only affect the proportion of stable carbon in BC, but also influence the quantification of long-term stability. Extrapolation from short-term decay to long-term stability may require prior knowledge about the decay rate of the labile fraction of BC. Some indications are provided for the short-term oxidation of BC.
Santana, Héctor; García, Gerardo; Vega, Maribel; Beldarraín, Alejandro; Páez, Rolando
2015-01-01
We report on the stability assessment of a recombinant human epidermal growth factor (rhEGF) freeze-dried formulation for wound healing by intra-lesional injections. The suitability of packaging material for the light protection of finished dried powder was evaluated after stressed exposure conditions. Degradation kinetics of powder for injection was investigated at concentrations of 25-250 μg/vial and temperatures of 45, 60, and 70 °C. The long-term stability was evaluated after storage at 25 ± 2 °C/60 ± 5% relative humidity (6 months) and 2-8 °C (24 months) in the dark and analyzed at several time points. The stability after reconstitution with various diluents was also assessed after 24 h storage at 2-8 °C. The rhEGF samples were analyzed for structural integrity by reversed-phase high-performance liquid chromatography (RP-HPLC), size-exclusion HPLC, and sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). Biological activity was investigated by measuring the cell proliferation in a murine fibroblast cell line. Results show that freeze-dried rhEGF in primary packaging only was photosensitive, as degradation by RP-HPLC that was completely suppressed by the secondary carton package was revealed. An increase in freeze-dried rhEGF stability was observed with the increase in protein concentration from 25 to 250 μg/vial. The long-term stability study showed no significant rhEGF degradation or physical change within the freeze-dried formulations containing 25 or 250 μg/vial of rhEGF. No physical, chemical or biological changes were observed for rhEGF after reconstitution in water for injection or 0.9% sodium chloride during the storage conditions studied. The stability of a recombinant human epidermal growth factor (rhEGF) freeze-dried formulation for wound healing by intra-lesional injections was assessed. The suitability of packaging material for the light protection of finished dried powder was evaluated after stressed exposure conditions. Degradation kinetics of powder for injection was investigated at concentrations of 25-250 μg/vial and temperatures of 45, 60, and 70 °C. The accelerated, long-term, and reconstitution stabilities were examined according to ICH guidelines for their utility time. The stability of rhEGF samples was analyzed by different chemical, physical, and biological activity assays. Results show that freeze-dried rhEGF in primary packaging only was photosensitive, as degradation by reversed-phase high performance liquid chromatography that was completely suppressed by the secondary carton package was revealed. An increase in freeze-dried rhEGF stability was observed with the increase in protein concentration. No significant rhEGF degradation or physical changes were observed within the freeze-dried formulations after 6 months storage at 25 ± 2 °C/60 ± 5% relative humidity or 24 months storage at 2-8 °C. No physical, chemical, or biological changes were observed for rhEGF after reconstitution in water for injection or 0.9% sodium chloride after 24 h storage at 2-8 °C. © PDA, Inc. 2015.
NASA Astrophysics Data System (ADS)
Baranov, A. A.; Ermak, S. V.; Kulachenkov, N. K.; Petrenko, M. V.; Sagitov, E. A.; Semenov, V. V.
2017-11-01
This paper presents the results of investigation Stark shift effect influence on the long-term stability of a dual scheme of quantum magnetometers. Such scheme allows suppressing Stark shift components when a certain pumping light polarization is applied. As a result, long-term stability of a quantum sensor increases. However, when low-frequency (LF) and microwave fields are attached to a single vapor cell a coherence circulation in hyperfine structure of alkali atoms takes place. Physical origin of this effect is associated with the so called “dressed” atom theory, when atom is “dressed” by LF field. It yields in multiphoton absorption and resonance frequency shift. First estimates for this shift based on density matrix evolution formalism are provided in the paper.
Note: Improving long-term stability of hot-wire anemometer sensors by means of annealing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundström, H., E-mail: hans.lundstrom@hig.se
2015-08-15
Annealing procedures for hot-wire sensors of platinum and platinum-plated tungsten have been investigated experimentally. It was discovered that the two investigated sensor metals behave quite differently during the annealing process, but for both types annealing may improve long-term stability considerably. Measured drift of sensors both without and with prior annealing is presented. Suggestions for suitable annealing temperatures and times are given.
Long-term Stabilization of Disturbed Slopes Resulting from Construction Operations
DOT National Transportation Integrated Search
2018-01-01
Highway construction disturbs soil, which must be stabilized to prevent migration of soil particles into water bodies. Stabilization is enforced by law, regulation, and a permit system. Stabilization is most efficiently attained by reestablishment of...
Wang, Chunyan; He, Nianpeng; Zhang, Jinjing; Lv, Yuliang; Wang, Li
2015-01-01
Alteration of the composition of soil organic matter (SOM) in Inner Mongolian grassland soils associated with the duration of grazing exclusion (GE) has been considered an important index for evaluating the restoring effects of GE practice. By using five plots from a grassland succession series from free grazing to 31-year GE, we measured the content of soil organic carbon (SOC), humic acid carbon (HAC), fulvic acid carbon (FAC), humin carbon (HUC), and humic acid structure to evaluate the changes in SOM composition. The results showed that SOC, HUC, and the ratios of HAC/FAC and HAC/extractable humus carbon (C) increased significantly with prolonged GE duration, and their relationships can be well fitted by positive exponential equations, except for FAC. In contrast, the HAC content increased logarithmically with prolonged GE duration. Long-term GE enhanced the content of SOC and soil humification, which was obvious after more than 10 years of GE. Solid-state 13C nuclear magnetic resonance spectroscopy showed that the ratios of alkyl C/O-alkyl C first decreased, and then remained stable with prolonged GE. Alternately, the ratios of aromaticity and hydrophobicity first increased, and then were maintained at relatively stable levels. Thus, a decade of GE improved the composition and structure of SOM in semiarid grassland soil and made it more stable. These findings provide new evidence to support the positive effects of long-term GE on soil SOC sequestration in the Inner Mongolian grasslands, in view of the improvement of SOM structure and stability. PMID:26057249
Wang, Chunyan; He, Nianpeng; Zhang, Jinjing; Lv, Yuliang; Wang, Li
2015-01-01
Alteration of the composition of soil organic matter (SOM) in Inner Mongolian grassland soils associated with the duration of grazing exclusion (GE) has been considered an important index for evaluating the restoring effects of GE practice. By using five plots from a grassland succession series from free grazing to 31-year GE, we measured the content of soil organic carbon (SOC), humic acid carbon (HAC), fulvic acid carbon (FAC), humin carbon (HUC), and humic acid structure to evaluate the changes in SOM composition. The results showed that SOC, HUC, and the ratios of HAC/FAC and HAC/extractable humus carbon (C) increased significantly with prolonged GE duration, and their relationships can be well fitted by positive exponential equations, except for FAC. In contrast, the HAC content increased logarithmically with prolonged GE duration. Long-term GE enhanced the content of SOC and soil humification, which was obvious after more than 10 years of GE. Solid-state 13C nuclear magnetic resonance spectroscopy showed that the ratios of alkyl C/O-alkyl C first decreased, and then remained stable with prolonged GE. Alternately, the ratios of aromaticity and hydrophobicity first increased, and then were maintained at relatively stable levels. Thus, a decade of GE improved the composition and structure of SOM in semiarid grassland soil and made it more stable. These findings provide new evidence to support the positive effects of long-term GE on soil SOC sequestration in the Inner Mongolian grasslands, in view of the improvement of SOM structure and stability.
Jia, Zhiqing; Zhu, Yajuan; Liu, Liying
2012-01-01
Background In a semi-arid ecosystem, water is one of the most important factors that affect vegetation dynamics, such as shrub plantation. A water use strategy, including the main water source that a plant species utilizes and water use efficiency (WUE), plays an important role in plant survival and growth. The water use strategy of a shrub is one of the key factors in the evaluation of stability and sustainability of a plantation. Methodology/Principal Findings Caragana intermedia is a dominant shrub of sand-binding plantations on sand dunes in the Gonghe Basin in northeastern Tibet Plateau. Understanding the water use strategy of a shrub plantation can be used to evaluate its sustainability and long-term stability. We hypothesized that C. intermedia uses mainly deep soil water and its WUE increases with plantation age. Stable isotopes of hydrogen and oxygen were used to determine the main water source and leaf carbon isotope discrimination was used to estimate long-term WUE. The root system was investigated to determine the depth of the main distribution. The results showed that a 5-year-old C. intermedia plantation used soil water mainly at a depth of 0–30 cm, which was coincident with the distribution of its fine roots. However, 9- or 25-year-old C. intermedia plantations used mainly 0–50 cm soil depth water and the fine root system was distributed primarily at soil depths of 0–50 cm and 0–60 cm, respectively. These sources of soil water are recharged directly by rainfall. Moreover, the long-term WUE of adult plantations was greater than that of juvenile plantations. Conclusions The C. intermedia plantation can change its water use strategy over time as an adaptation to a semi-arid environment, including increasing the depth of soil water used for root growth, and increasing long-term WUE. PMID:23029303
Simulation Study Using a New Type of Sample Variance
NASA Technical Reports Server (NTRS)
Howe, D. A.; Lainson, K. J.
1996-01-01
We evaluate with simulated data a new type of sample variance for the characterization of frequency stability. The new statistic (referred to as TOTALVAR and its square root TOTALDEV) is a better predictor of long-term frequency variations than the present sample Allan deviation. The statistical model uses the assumption that a time series of phase or frequency differences is wrapped (periodic) with overall frequency difference removed. We find that the variability at long averaging times is reduced considerably for the five models of power-law noise commonly encountered with frequency standards and oscillators.
Beirowski, Jakob; Inghelbrecht, Sabine; Arien, Albertina; Gieseler, Henning
2012-01-01
On the basis of a previously developed formulation and process guideline for lyophilized, highly concentrated drug nanosuspensions for parenteral use, it was the purpose of this study to demonstrate that the original nanoparticle size distribution can be preserved over a minimum period of 3 months, even if aggressive primary drying conditions are used. Critical factors were evaluated that were originally believed to affect storage stability of freeze-dried drug nanoparticles. It was found that the nature and concentration of the steric stabilizer, such as Poloxamer 338 and Cremophor EL, are the most important factors for long-term stability of such formulations, independent of the used drug compound. The rational choice of an adequate steric stabilizer, namely Poloxamer 338, in combination with various lyoprotectants seems crucial to prevent physical instabilities of the lyophilized drug nanoparticles during short-term stability experiments at ambient and accelerated conditions. A 200 mg/mL concentration of nanoparticles could successfully be stabilized over the investigated time interval. In the course of the present experiments, polyvinylpyrrolidone, type K15 was found superior to trehalose or sucrose in preserving the original particle size distribution, presumably based on its surface-active properties. Lastly, it was demonstrated that lower water contents are generally beneficial to stabilize such systems. Copyright © 2011 Wiley-Liss, Inc.
Long-Term High-Level Defense-Waste technology
NASA Astrophysics Data System (ADS)
1982-07-01
In the residual liquid solidification effort, the primary alternative studied is the wiped film evaporator approach to solidifying salt well pumped liquids and returning the molten material to single shell tanks for microwave final stabilization to a hard dry product. Both systems analysis and experimental work are proceeding to evaluate this approach. The primary alternative for in situ stabilization of in-tank wastes is microwave drying of wet salt cake and unpumped sludges. Experimental work was successfully conducted on a 1/12 scale tank containing wet synthetic salt cake. Related systems analysis of a full scale system was initiated.
Agreda, Patricia M.; Beitman, Gerard H.; Gutierrez, Erin C.; Harris, James M.; Koch, Kristopher R.; LaViers, William D.; Leitch, Sharon V.; Maus, Courtney E.; McMillian, Ray A.; Nussbaumer, William A.; Palmer, Marcus L. R.; Porter, Michael J.; Richart, Gregory A.; Schwab, Ryan J.
2013-01-01
We evaluated the effect of storage at 2 to 8°C on the stability of human genomic and human papillomavirus (HPV) DNA stored in BD SurePath and Hologic PreservCyt liquid-based cytology media. DNA retained the ability to be extracted and PCR amplified for more than 2.5 years in both medium types. Prior inability to detect DNA in archived specimens may have been due to failure of the extraction method to isolate DNA from fixed cells. PMID:23678069
Andrysek, Jan; Wright, F Virginia; Rotter, Karin; Garcia, Daniela; Valdebenito, Rebeca; Mitchell, Carlos Alvarez; Rozbaczylo, Claudio; Cubillos, Rafael
2017-05-01
The purpose of this study was to clinically evaluate the automatic stance-phase lock (ASPL) knee mechanism against participants' existing weight-activated braking (WAB) prosthetic knee joint. This prospective crossover study involved 10 young adults with an above-knee amputation. Primary measurements consisted of tests of walking speeds and capacity. Heart rate was measured during the six-minute walk test and the Physiological Cost Index (PCI) which was calculated from heart rate estimated energy expenditure. Activity was measured with a pedometer. User function and quality of life were assessed using the Lower Limb Function Questionnaire (LLFQ) and Prosthetic Evaluation Questionnaire (PEQ). Long-term follow-up over 12 months were completed. Walking speeds were the same for WAB and APSL knees. Energy expenditure (PCI) was lower for the ASPL knees (p = 0.007). Step counts were the same for both knees, and questionnaires indicated ASPL knee preference attributed primarily to knee stability and improved walking, while limitations included terminal impact noise. Nine of 10 participants chose to keep using the ASPL knee as part of the long-term follow-up. Potential benefits of the ASPL knee were identified in this study by functional measures, questionnaires and user feedback, but not changes in activity or the PEQ.
Flight service evaluation of composite helicopter components
NASA Technical Reports Server (NTRS)
Mardoian, George H.; Ezzo, Maureen B.
1994-01-01
This paper presents the results of a NASA funded contract and Sikorsky research and development programs to evaluate structural composite components in flight service on Sikorsky Model S-76 helicopters. Selected components were removed and tested at prescribed intervals over a nine year time frame. Four horizontal stabilizers and thirteen tail rotor spars were returned from commercial service in West Palm Beach, Florida and in the Gulf Coast region of Louisiana to determine the long term effects of operations in hot and humid climates on component performance. Concurrent with the flight component evaluation, panels of materials used in their fabrication were exposed to the environment in ground racks. Selected panels were tested annually to determine the effects of exposure on physical and mechanical properties. The results of 55,741 component flight hours and 911 months of field exposure are reported and compared with initial Federal Aviation Administration (FAA) certification data. The findings of this program have provided increased confidence in the long term durability of advanced composite materials used in helicopter structural applications.
Ulkowski, Piotr; Bulski, Wojciech; Chełmiński, Krzysztof
2015-10-01
Unidos 10001, Unidos E (10008/10009) and Dose 1 electrometers from 14 radiotherapy centres were calibrated 3-4 times over a long period of time, together with Farmer type (PTW 30001, 30013, Nuclear Enterprises 2571 and Scanditronix-Wellhofer FC65G) cylindrical ionization chambers and plane-parallel type chambers (PTW Markus 23343 and Scanditronix-Wellhofer PPC05). On the basis of the long period of repetitive establishing of calibration coefficients for the same electrometers and ionization chambers, the accuracy of electrometers and the long-term stability of ionization chambers were examined. All measurements were carried out at the same laboratory, by the same staff, according to the same IAEA recommendations. A good accuracy and long-term stability of the dosimeters used in Polish radiotherapy centres was observed. These values were within 0.1% for electrometers and 0.2% for the chambers with electrometers. Furthermore, these values were not observed to vary over time. The observations confirm the opinion that the requirement of calibration of the dosimeters more often than every 2 years is not justified. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Becker, Ina; Strauch, Sebastian M.; Hauslage, Jens; Lebert, Michael
2017-05-01
The unicellular freshwater flagellate Euglena gracilis has a highly developed sensory system. The cells use different stimuli such as light and gravity to orient themselves in the surrounding medium to find areas for optimal growth. Due to the ability to produce oxygen and consume carbon dioxide, Euglena is a suitable candidate for life support systems. Participation in a long-term space experiment would allow for the analysis of changes and adaptations to the new environment, and this could bring new insights into the mechanism of perception of gravity and the associated signal transduction chain. For a molecular analysis of transcription patterns, an automated system is necessary, capable of performing all steps from taking a sample, processing it and generating data. One of the developmental steps is to find long-term stable reagents and materials and test them for stability at higher-than-recommended temperature conditions during extended storage time. We investigated the usability of magnetic beads in an Euglena specific lysis buffer after addition of the RNA stabilizer Dithiothreitol over 360 days and the lysis buffer with the stabilizer alone over 455 days at the expected storage temperature of 19 °C. We can claim that the stability is not impaired at all after an incubation period of over one year. This might be an interesting result for researchers who have to work under non-standard lab conditions, as in biological or medicinal fieldwork.
Long-term stability of the Wechsler Intelligence Scale for Children--Fourth Edition.
Watkins, Marley W; Smith, Lourdes G
2013-06-01
Long-term stability of the Wechsler Intelligence Scale for Children-Fourth Edition (WISC-IV; Wechsler, 2003) was investigated with a sample of 344 students from 2 school districts twice evaluated for special education eligibility at an average interval of 2.84 years. Test-retest reliability coefficients for the Verbal Comprehension Index (VCI), Perceptual Reasoning Index (PRI), Working Memory Index (WMI), Processing Speed Index (PSI), and the Full Scale IQ (FSIQ) were .72, .76, .66, .65, and .82, respectively. As predicted, the test-retest reliability coefficients for the subtests (Mdn = .56) were generally lower than the index scores (Mdn = .69) and the FSIQ (.82). On average, subtest scores did not differ by more than 1 point, and index scores did not differ by more than 2 points across the test-retest interval. However, 25% of the students earned FSIQ scores that differed by 10 or more points, and 29%, 39%, 37%, and 44% of the students earned VCI, PRI, WMI, and PSI scores, respectively, that varied by 10 or more points. Given this variability, it cannot be assumed that WISC-IV scores will be consistent across long test-retest intervals for individual students. PsycINFO Database Record (c) 2013 APA, all rights reserved.
Development of a Hard X-ray Beam Position Monitor for Insertion Device Beams at the APS
NASA Astrophysics Data System (ADS)
Decker, Glenn; Rosenbaum, Gerd; Singh, Om
2006-11-01
Long-term pointing stability requirements at the Advanced Photon Source (APS) are very stringent, at the level of 500 nanoradians peak-to-peak or better over a one-week time frame. Conventional rf beam position monitors (BPMs) close to the insertion device source points are incapable of assuring this level of stability, owing to mechanical, thermal, and electronic stability limitations. Insertion device gap-dependent systematic errors associated with the present ultraviolet photon beam position monitors similarly limit their ability to control long-term pointing stability. We report on the development of a new BPM design sensitive only to hard x-rays. Early experimental results will be presented.
NASA Astrophysics Data System (ADS)
Chou, Yeong-Shyung; Stevenson, Jeffry W.; Choi, Jung-Pyung
2014-07-01
A generic solid oxide fuel cell stack test fixture was developed to evaluate candidate materials and processing under realistic conditions. Part III of the work investigated the stability of Ce-(Mn,Co) spinel coating, AISI441 metallic interconnect, alumina coating, and cell's degradation. After 6000 h test, the spinel coating showed densification with some diffusion of Cr. At the metal interface, segregation of Si and Ti was observed, however, no continuous layer formed. The alumina coating for perimeter sealing areas appeared more dense and thick at the air side than the fuel side. Both the spinel and alumina coatings remained bonded. EDS analysis of Cr within the metal showed small decrease in concentration near the coating interface and would expect to cause no issue of Cr depletion. Inter-diffusion of Ni, Fe, and Cr between spot-welded Ni wire and AISI441 interconnect was observed and Cr-oxide scale formed along the circumference of the weld. The microstructure of the anode and cathode was discussed relating to degradation of the top and middle cells. Overall, the Ce-(Mn,Co) spinel coating, alumina coating, and AISI441 steel showed the desired long-term stability and the developed generic stack fixture proved to be a useful tool to validate candidate materials for SOFC.
Modified Direct-Type Septal Extension Grafts: Their Stability and Usefulness in Asian Rhinoplasty.
Han, So-Eun; Han, Kihwan; Choi, Jaehoon; Yun, Tae Bin
2017-03-01
In Asian rhinoplasty, many autogenous cartilage grafts are required for correction of the nasal tip and columella, but the amount has limitations. A modified direct-type septal extension graft, in continuity with the entire caudal border of the septal cartilage with an edge-to-edge coaptation, can effectively and concomitantly correct the nasal tip and columella deformities using a limited amount of septal cartilage graft. The purpose of this study was to evaluate long-term cosmetic outcomes and stability from the modified direct extension grafts. Fifty-seven patients with a follow-up of more than 1 year were enrolled in the study. A total of 11 measurement items were evaluated from basal and right lateral views by photogrammetry using standardized clinical photographic techniques. The overall mean follow-up period was 20.4 months. When comparing the preoperative and postoperative values, the nasal tip projection, nasal bridge length, nasal tip angle, height of nose, and the columellar labial angle increased significantly; additionally, the soft nose width index, width between ac-ac index, nostril axis inclination, columellar length (Rt-Lt), and the alar length (Rt-Lt) decreased significantly. No resorption, buckling, or displacement of the graft was observed during the follow-up period. The modified direct extension graft demonstrated a marked aesthetic improvement in the nasal tip and columella, and it provided long-term stability. Therefore, the modified direct extension graft is useful for correction of the nasal tip and columella in Asian rhinoplasty.
Pierzyńska-Mach, Agnieszka; Janowski, Paweł A; Dobrucki, Jurek W
2014-08-01
Acidic vesicles can be imaged and tracked in live cells after staining with several low molecular weight fluorescent probes, or with fluorescently labeled proteins. Three fluorescent dyes, acridine orange, LysoTracker Red DND-99, and quinacrine, were evaluated as acidic vesicle tracers for confocal fluorescence imaging and quantitative analysis. The stability of fluorescent signals, achievable image contrast, and phototoxicity were taken into consideration. The three tested tracers exhibit different advantages and pose different problems in imaging experiments. Acridine orange makes it possible to distinguish acidic vesicles with different internal pH but is fairly phototoxic and can cause spectacular bursts of the dye-loaded vesicles. LysoTracker Red is less phototoxic but its rapid photobleaching limits the range of useful applications considerably. We demonstrate that quinacrine is most suitable for long-term imaging when a high number of frames is required. This capacity made it possible to trace acidic vesicles for several hours, during a process of drug-induced apoptosis. An ability to record the behavior of acidic vesicles over such long periods opens a possibility to study processes like autophagy or long-term effects of drugs on endocytosis and exocytosis. © 2014 International Society for Advancement of Cytometry.
Ultra Stable Microwave Radiometers for Future Sea Surface Salinity Missions
NASA Technical Reports Server (NTRS)
Wilson, William J.; Tanner, Alan B.; Pellerano, Fernando A.; Horgan, Kevin A.
2005-01-01
The NASA Earth Science System Pathfinder (ESSP) mission Aquarius will measure global sea surface salinity with 100-km spatial resolution every 8 days with an average monthly salinity accuracy of 0.2 psu (parts per thousand). This requires an L-band low-noise radiometer with the long-term calibration stability of less than 0.1 K over 8 days. This three-year research program on ultra stable radiometers has addressed the radiometer requirements and configuration necessary to achieve this objective for Aquarius and future ocean salinity missions. The system configuration and component performance have been evaluated with radiometer testbeds at both JPL and GSFC. The research has addressed several areas including component characterization as a function of temperature, a procedure for the measurement and correction for radiometer system non-linearity, noise diode calibration versus temperature, low noise amplifier performance over voltage, and temperature control requirements to achieve the required stability. A breadboard radiometer, utilizing microstrip-based technologies, has been built to demonstrate this long-term stability. This report also presents the results of the radiometer test program, a detailed radiometer noise model, and details of the operational switching sequence optimization that can be used to achieve the low noise and stability requirements. Many of the results of this research have been incorporated into the Aquarius radiometer design and will allow this instrument to achieve its goals.
Long-term follow-up of the surgical management of neuropathic arthropathy of the spine.
Haus, Brian M; Hsu, Andrew R; Yim, Eugene S; Meter, Jeffrey J; Rinsky, Lawrence A
2010-06-01
No studies have discussed the long-term surgical management and outcomes of Charcot arthropathy of the spine. This case series presents nine patients treated over 30 years. The study hypothesis was that surgery would reduce instability, pain, recurrence, and the need for revision surgery in the long-term, given previous study findings of successful fusion of Charcot spine in the short-term. To evaluate the long-term outcomes of surgery for Charcot spine. Retrospective case series. Cases took place at Stanford University Medical Center and Santa Clara Valley Medical Center. All patients had either complete paraplegia or dense paraparesis with both major motor and sensory deficits. Seven patients developed Charcot spine after spinal instrumentation for trauma, one after scoliosis repair for meningomyelocele, and one after spinal instrumentation for neuromuscular scoliosis caused by birth injury resulting in C6-C7 quadraplegia. Average time between initial instrumentation and development of Charcot spine was 7.6 years. Two patients underwent posterior fusion alone, six had anterior-posterior fusion, and one was managed with thoracolumbar orthosis. Average follow-up was 14.3 years. Revisions were necessary in 75% (6 of 8) of patients for complications including nonunion, new Charcot joints, recurrent hardware failure, and osteomyelitis. Achieving fusion often required multiple operations, and there were no deaths or neurologic complications. Long-term follow-up showed a high rate of revision surgery. Solid fusions often resulted in late breakdown or new junctional Charcot arthropathies. Patients initially fused to the lumbar spine instead of the sacrum or pelvis had a higher rate of developing another Charcot joint. Fusion was often difficult with persistent nonunions and functional deficits because of decreased mobility. We recommend that Charcot spine well tolerated without skin, seating problems, or dysreflexia should be cautiously observed with conservative management. For surgical care, we recommend three-column stabilization with either combined anterior-posterior or all posterior approaches with anterior support to obtain and secure greater long-term stability. Copyright 2010 Elsevier Inc. All rights reserved.
Design and physicochemical stability studies of paediatric oral formulations of sildenafil.
Provenza, N; Calpena, A C; Mallandrich, M; Halbaut, L; Clares, B
2014-01-02
Personalized medicine is a challenging research area in paediatric treatments. Elaborating new paediatric formulations when no commercial forms are available is a common practice in pharmacy laboratories; among these, oral liquid formulations are the most common. But due to the lack of specialized equipment, frequently studies to assure the efficiency and safety of the final medicine cannot be carried out. Thus the purpose of this work was the development, characterization and stability evaluation of two oral formulations of sildenafil for the treatment of neonatal persistent pulmonary hypertension. After the establishment of a standard operating procedure (SOP) and elaboration, the physicochemical stability parameters appearance, pH, particle size, rheological behaviour and drug content of formulations were evaluated at three different temperatures for 90 days. Equally, prediction of long term stability, as well as, microbiological stability was performed. Formulations resulted in a suspension and a solution slightly coloured exhibiting fruity odour. Formulation I (suspension) exhibited the best physicochemical properties including Newtonian behaviour and uniformity of API content above 90% to assure an exact dosification process. Copyright © 2013 Elsevier B.V. All rights reserved.
Zhang, Qiang; Cheng, Cheng-Kung; Wei, Hung-Wen; Dong, Xiang; Chen, Yi-Ting; Lai, Yu-Shu; Wang, Yan
2013-01-01
There is a relatively high failure rate of the femoral component in patients with avascular necrosis at the intermediate-term follow-up. Improving the geometrical fit of the femoral stem against the medullary canal may help to provide long-term survivorship of the hip replacement for patients with avascular necrosis. We designed a specific stem, based on morphometric studies of proximal femoral canals in Chinese avascular necrosis patients and evaluated the stem by finite element analyses, comparing the novel stem with two commercially available and commonly used stems. The morphometric data from avascular necrosis patients showed specific geometric differences in the proximal femoral canal, including profile curves in both the sagittal and coronary planes than the patients with femoral neck fracture. The shorter stemmed prostheses (Fitmore(®) and our stem) performed better than the longer stemmed prosthesis (VerSys(®)). This is the first study to investigate the femoral geometries of Chinese avascular necrosis patients. Our stem provides better stability and is theoretically beneficial to bone ingrowth, which may increase the long-term stability and fixation of the implant.
CW injection locking for long-term stability of frequency combs
NASA Astrophysics Data System (ADS)
Williams, Charles; Quinlan, Franklyn; Delfyett, Peter J.
2009-05-01
Harmonically mode-locked semiconductor lasers with external ring cavities offer high repetition rate pulse trains while maintaining low optical linewidth via long cavity storage times. Continuous wave (CW) injection locking further reduces linewidth and stabilizes the optical frequencies. The output can be stabilized long-term with the help of a modified Pound-Drever-Hall feedback loop. Optical sidemode suppression of 36 dB has been shown, as well as RF supermode noise suppression of 14 dB for longer than 1 hour. In addition to the injection locking of harmonically mode-locked lasers requiring an external frequency source, recent work shows the viability of the injection locking technique for regeneratively mode-locked lasers, or Coupled Opto-Electronic Oscillators (COEO).
Rocha, Caroline Andrade; Almeida, Renato Rodrigues de; Henriques, José Fernando Castanha; Flores-Mir, Carlos; Almeida, Marcio Rodrigues de
2016-01-01
To evaluate the stability of mesiodistal inclination of maxillary molars produced by a pendulum appliance, five years after completion of orthodontic treatment. Angulation changes were compared to an untreated sample. The sample consisted of 20 patients (14 females and 6 males) with Class II, Division 1 malocclusion that was treated through molar distalization with a pendulum appliance followed by cervical headgear and full fixed appliances. Maxillary molar inclination was evaluated through panoramic radiograph. The mean age at pretreatment was 14.3 ± 1.6 years, whereas at immediate post-treatment it was 18.6 ± 1.8 years, and at long-term post-treatment it was 23.8 ± 2.0 years. A control group of 16 untreated individuals with untreated normocclusion ranging in age from 12 to 17 years old were used as comparison group. Data were statistically analyzed with independent t-tests and ANOVA test followed by Tukey post-hoc tests. Statistically significant differences were found between T1(94.50) and T2 (98.80) as well as between T2 and T3 (94.70) for maxillary first molars. Maxillary second molars did not show any statistically significant positional changes during the evaluated time periods T1 (107.50), T2 (109.30) and T3 (106.90). Although maxillary first molars underwent distal crown inclination immediately after treatment, approximately five years thereafter their roots tended to upright close to the pretreatment positions.
Long-term stability of GOES-8 and -9 attitude control
NASA Astrophysics Data System (ADS)
Carr, James L.
1996-10-01
An independent audit of the in-orbit behavior of the GOES-8 and GOES-9 satellites has been conducted for the NASA/GSFC. This audit utilized star and landmark observations from the GOES imager to determine long-term histories for spacecraft attitude, orbital position, and instrument internal misalignments. The paper presents results from this audit. Long-term drifts are found in the attitude histories, whereas the misalignment histories are shown to be diurnally stable. The GOES image navigation and registration system is designed to compensate for instrument internal misalignments, and both the diurnally repeatable and drift components of the attitude. Correlations between GOES-8 and GOES-9 long-term roll and pitch drifts implicate the Earth sensor as the origin of these observed drifts. This results clearly demonstrates the enhanced registration stability to be obtained with stellar inertial attitude determination replacing or supplementing Earth sensor control on future GOES missions.
Application of Millisecond Pulsar Timing to the Long-Term Stability of Clock Ensembles
NASA Technical Reports Server (NTRS)
Foster, Roger S.; Matsakis, Demetrios N.
1996-01-01
We review the application of millisecond pulsars to define a precise long-term standard and positional reference system in a nearly inertial reference frame. We quantify the current timing precision of the best millisecond pulsars and define the required precise time and time interval (PTTI) accuracy and stability to enable time transfer via pulsars. Pulsars may prove useful as independent standards to examine decade-long timing stability and provide an independent natural system within which to calibrate any new, perhaps vastly improved atomic time scale. Since pulsar stability appears to be related to the lifetime of the pulsar, the new millisecond pulsar J173+0747 is projected to have a 100-day accuracy equivalent to a single HP5071 cesium standard. Over the last five years, dozens of new millisecond pulsars have been discovered. A few of the new millisecond pulsars may have even better timing properties.
Joint Development of a Fourth Generation Single Crystal Superalloy
NASA Technical Reports Server (NTRS)
Walston, S.; Cetel, A.; MacKay, R.; OHara, K.; Duhl, D.; Dreshfield, R.
2004-01-01
A new, fourth generation, single crystal superalloy has been jointly developed by GE Aircraft Engines, Pratt & Whitney, and NASA. The focus of the effort was to develop a turbine airfoil alloy with long-term durability for use in the High Speed Civil Transport. In order to achieve adequate long-time strength improvements at moderate temperatures and retain good microstructural stability, it was necessary to make significant composition changes from 2nd and 3rd generation single crystal superalloys. These included lower chromium levels, higher cobalt and rhenium levels and the inclusion of a new alloying element, ruthenium. It was found that higher Co levels were beneficial to reducing both TCP precipitation and SRZ formation. Ruthenium caused the refractory elements to partition more strongly to the ' phase, which resulted in better overall alloy stability. The final alloy, EPM 102, had significant creep rupture and fatigue improvements over the baseline production alloys and had acceptable microstructural stability. The alloy is currently being engine tested and evaluated for advanced engine applications.
Physical and chemical stability of pemetrexed in infusion solutions.
Zhang, Yanping; Trissel, Lawrence A
2006-06-01
Pemetrexed is a multitargeted, antifolate, antineoplastic agent that is indicated for single-agent use in locally advanced or metastatic non-small-cell lung cancer after prior chemotherapy and in combination with cisplatin for the treatment of malignant pleural mesothelioma not treatable by surgery. Currently, there is no information on the long-term stability of pemetrexed beyond 24 hours. To evaluate the longer-term physical and chemical stability of pemetrexed 2, 10, and 20 mg/mL in polyvinyl chloride (PVC) bags of dextrose 5% injection and NaCl 0.9% injection. Triplicate samples of pemetrexed were prepared in the concentrations and infusion solutions required. Evaluations for physical and chemical stability were performed initially and over 2 days at 23 degrees C protected from light and exposed to fluorescent light, and over 31 days of storage at 4 degrees C protected from light. Physical stability was assessed using turbidimetric and particulate measurement as well as visual observation. Chemical stability was evaluated by HPLC. All pemetrexed solutions remained chemically stable, with little or no loss of pemetrexed over 2 days at 23 degrees C, protected from light and exposed to fluorescent light, and over 31 days of storage at 4 degrees C, protected from light. The room temperature samples were physically stable throughout the 48 hour test period. However, pemetrexed admixtures developed large numbers of microparticulates during refrigerated storage exceeding 24 hours. Pemetrexed is chemically stable for 2 days at room temperature and 31 days refrigerated in dextrose 5% injection and NaCl 0.9% injection. However, substantial numbers of microparticulates may form in pemetrexed diluted in the infusion solutions in PVC bags, especially during longer periods of refrigerated storage. Limiting the refrigerated storage period to the manufacturer-recommended 24 hours will limit particulate formation.
Rokn, A; Bassir, S H; Rasouli Ghahroudi, A A; Kharazifard, M J; Manesheof, R
2016-01-01
The present study aimed to evaluate the long-term stability of esthetic outcomes of soft tissue around maxillary anterior single-tooth implants after 10-to-12 years of loading. Patients who had been treated for single-tooth implants in the anterior maxilla between February 2000 and July 2002 were invited to participate in the study. All implants had been placed according to delayed implant placement and conventional loading protocols without any connective tissue graft or papilla preservation flaps. Pink Esthetic Score (PES) was rated using standardized clinical photographs to assess the esthetic outcomes of the implant treatment at the time of crown placement and at time of follow-up examination which was at least 10 years after the crown placement. A total of 19 patients were included. The mean score of PES was 11.63 (SD 1.61; range 7-14) at baseline. After 10-to-12 years of function, a mean PES score of 11.05 (SD 2.09; range 6-14) was recorded. No significant differences were found in the esthetic outcomes, categorized based on clinically relevant levels, between the baseline and follow-up session (p>0.05). Within limitation of the present study, it can be concluded that the esthetic outcomes of soft tissue around the maxillary anterior single-tooth implants placed using conventional implant placement technique remained stable in the long-term.
Kondaveeti, Sanath; Kakarla, Ramesh; Kim, Hong Suck; Kim, Byung-Goon; Min, Booki
2018-02-01
This study evaluates long-term stability of low-cost separators in single-chamber bottle-type microbial fuel cells with domestic wastewater. Low-cost separators tested in this study were nonwoven fabrics (NWF) of polypropylene (PP80, PP100), textile fabrics of polyphenylene sulfide (PPS), sulfonated polyphenylene sulfide (SPPS), and cellulose esters. NWF PP80 separator generated the highest power density of 280 mW/m 2 , which was higher than with ion-exchange membranes (cation exchange membrane; CEM = 271 mW/m 2 , cation exchange membrane; CMI = 196 mW/m 2 , Nafion = 260 mW/m 2 ). MFC operations with other size-selective separators such as SPPS, PPS, and cellulose esters exhibited power densities of 261, 231, and 250 mW/m 2 , respectively. During a 280-day operation, initial power density of PP80 (278 mW/m 2 ) was decreased to 257 mW/m 2 , but this decrease was smaller than with others (Nafion: 265-230 mW/m 2 ; PP100: 220-126 mW/m 2 ). The anode potential of around -430 mV did not change much with all separators in the long-term operation, but the initial cathode potential gradually decreased. Fouling analysis suggested that the presence of carbonaceous substance on Nafion and PP80 after 280 days of operation and Nafion was subject to be more biofouling.
He, Wei; Tan, Yanan; Tian, Zhiqiang; Chen, Lingyun; Hu, Fuqiang; Wu, Wei
2011-01-01
Nanoemulsions stabilized by traditional emulsifiers raise toxicological concerns for long-term treatment. The present work investigates the potential of food proteins as safer stabilizers for nanoemulsions to deliver hydrophobic drugs. Nanoemulsions stabilized by food proteins (soybean protein isolate, whey protein isolate, β-lactoglobulin) were prepared by high-pressure homogenization. The toxicity of the nanoemulsions was tested in Caco-2 cells using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazoliumbromide viability assay. In vivo absorption in rats was also evaluated. Food protein-stabilized nanoemulsions, with small particle size and good size distribution, exhibited better stability and biocompatibility compared with nanoemulsions stabilized by traditional emulsifiers. Moreover, β-lactoglobulin had a better emulsifying capacity and biocompatibility than the other two food proteins. The pancreatic degradation of the proteins accelerated drug release. It is concluded that an oil/water nanoemulsion system with good biocompatibility can be prepared by using food proteins as emulsifiers, allowing better and more rapid absorption of lipophilic drugs. PMID:21468355
He, Wei; Tan, Yanan; Tian, Zhiqiang; Chen, Lingyun; Hu, Fuqiang; Wu, Wei
2011-01-01
Nanoemulsions stabilized by traditional emulsifiers raise toxicological concerns for long-term treatment. The present work investigates the potential of food proteins as safer stabilizers for nanoemulsions to deliver hydrophobic drugs. Nanoemulsions stabilized by food proteins (soybean protein isolate, whey protein isolate, β-lactoglobulin) were prepared by high-pressure homogenization. The toxicity of the nanoemulsions was tested in Caco-2 cells using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazoliumbromide viability assay. In vivo absorption in rats was also evaluated. Food protein-stabilized nanoemulsions, with small particle size and good size distribution, exhibited better stability and biocompatibility compared with nanoemulsions stabilized by traditional emulsifiers. Moreover, β-lactoglobulin had a better emulsifying capacity and biocompatibility than the other two food proteins. The pancreatic degradation of the proteins accelerated drug release. It is concluded that an oil/water nanoemulsion system with good biocompatibility can be prepared by using food proteins as emulsifiers, allowing better and more rapid absorption of lipophilic drugs.
[Apical resorption in pre-surgical orthodontics].
Piasente, M; Merlini, C; Amelotti, C; Antonioli, M; Roghi, M
1991-07-15
Apical root resorption is a frequent phenomenon observed in pre-surgical orthodontic; the reason is double: we deal with adult patients and we often move the teeth in the opposite direction compared to the position obtained in previous inefficacious orthodontic treatments. Notwithstanding the amount of apical root resorption we couldn't record an hyper-mobility of the teeth and a long term evaluation of occlusal stability didn't show any significant change.
Effectiveness of Career Counseling: A One-Year Follow-Up
ERIC Educational Resources Information Center
Perdrix, Sophie; Stauffer, Sarah; Masdonati, Jonas; Massoudi, Koorosh; Rossier, Jerome
2012-01-01
The short-term effectiveness of career counseling is well supported in the literature. However, the long-term impact is often overlooked. This study quantitatively investigated the long-term stability of the positive effects gained through the career counseling process and qualitatively observed participants' levels of career project…
Foster, William J; Meen, James K; Fox, Donald A
2013-03-01
Perovskite compounds, including lead-lanthanum-zirconium titanate (PLZT), have wide technological application because of their unique physical properties. The use of PLZT in neuro-prosthetic systems, such as retinal implants, has been discussed in a number of publications. Since inorganic lead is a retinotoxic compound that produces retinal degeneration, the long-term stability of PLZT in aqueous biological solutions must be determined. We evaluated the stability and effects of prolonged immersion of a PLZT-coated crystal in a buffered balanced salt solution. Scanning Electron Microscopy and Electron Dispersive Spectroscopy (EDS) using a JEOL JSM 5410 microscope equipped with EDS were utilized to evaluate the samples before and after prolonged immersion. We found that lead and other constituents of PLZT leached into the surrounding aqueous medium. By comparing the unit cell of PLZT with that of CaTiO(3), which has been found to react with aqueous fluids, Lead is in the same site in PLZT as Ca is in CaTiO(3). It is thus reasonable that PLZT will react with aqueous solutions. The results suggest that PLZT must either be coated with a protective layer or is not appropriate for long-term in vivo or in vitro biological applications.
Foster, William J.; Meen, James K.; Fox, Donald A.
2016-01-01
Context Perovskite compounds, including Lead-Lanthanum-Zirconium Titanate (PLZT), have wide technological application because of their unique physical properties. The use of PLZT in neuro-prosthetic systems, such as retinal implants, have been discussed in a number of publications. Since inorganic lead is a retinotoxic compound that produces retinal degeneration, the long-term stability of PLZT in aqueous biological solutions must be determined. Objective We evaluated the stability and effects of prolonged immersion of a PLZT-coated crystal in a buffered balanced salt solution. Materials and Methods Scanning Electron Microscopy and Electron Dispersive Spectroscopy (EDS) using a JEOL JSM 5410 microscope equipped with EDS were utilized to evaluate the samples before and after prolonged immersion. Results We found that lead and other constituents of PLZT leached into the surrounding aqueous medium. Discussion By comparing the unit cell of PLZT with that of CaTiO3, which has been found to react with aqueous fluids, Lead is in the same site in PLZT as Ca is in CaTiO3. It is thus reasonable that PLZT will react with aqueous solutions. Conclusion The results suggest that PLZT must either be coated with a protective layer or is not appropriate for long-term in vivo or in vitro biological applications. PMID:22697294
Where Is the “Optimal” Fontan Hemodynamics?
2017-01-01
Fontan circulation is generally characterized by high central venous pressure, low cardiac output, and slightly low arterial oxygen saturation, and it is quite different from normal biventricular physiology. Therefore, when a patient with congenital heart disease is selected as a candidate for this type of circulation, the ultimate goals of therapy consist of 2 components. One is a smooth adjustment to the new circulation, and the other is long-term circulatory stabilization after adjustment. When either of these goals is not achieved, the patient is categorized as having “failed” Fontan circulation, and the prognosis is dismal. For the first goal of smooth adjustment, a lot of effort has been made to establish criteria for patient selection and intensive management immediately after the Fontan operation. For the second goal of long-term circulatory stabilization, there is limited evidence of successful strategies for long-term hemodynamic stabilization. Furthermore, there have been no data on optimal hemodynamics in Fontan circulation that could be used as a reference for patient management. Although small clinical trials and case reports are available, the results cannot be generalized to the majority of Fontan survivors. We recently reported the clinical and hemodynamic characteristics of early and late failing Fontan survivors and their association with all-cause mortality. This knowledge could provide insight into the complex Fontan pathophysiology and might help establish a management strategy for long-term hemodynamic stabilization. PMID:29035429
NASA Astrophysics Data System (ADS)
Lipka, Michał; Parniak, Michał; Wasilewski, Wojciech
2017-09-01
We present an experimental realization of the optical frequency locked loop applied to long-term frequency difference stabilization of broad-line DFB lasers along with a new independent method to characterize relative phase fluctuations of two lasers. The presented design is based on a fast photodiode matched with an integrated phase-frequency detector chip. The locking setup is digitally tunable in real time, insensitive to environmental perturbations and compatible with commercially available laser current control modules. We present a simple model and a quick method to optimize the loop for a given hardware relying exclusively on simple measurements in time domain. Step response of the system as well as phase characteristics closely agree with the theoretical model. Finally, frequency stabilization for offsets within 4-15 GHz working range achieving <0.1 Hz long-term stability of the beat note frequency for 500 s averaging time period is demonstrated. For these measurements we employ an I/Q mixer that allows us to precisely and independently measure the full phase trace of the beat note signal.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lill, R.; Sereno, N.; Yang, B.
The Advanced Photon Source (APS) is currently in the preliminary design phase for the multi-bend achromat (MBA) lattice upgrade. Beam stability is critical for the MBA and will require long term drift defined as beam mo-tion over a seven-day timescale to be no more than 1 mi-cron at the insertion device locations and beam angle change no more than 0.25 micro-radian. Mechanical stabil-ity of beam position monitor (BPM) pickup electrodes mounted on insertion device vacuum chambers place a fun-damental limitation on long-term beam stability for inser-tion device beamlines. We present the design and imple-mentation of prototype mechanical motion system (MMS)more » instrumentation for quantifying this type of motion specif-ically in the APS accelerator tunnel and experiment hall floor under normal operating conditions. The MMS pres-ently provides critical position information on the vacuum chamber and BPM support systems. Initial results of the R&D prototype systems have demonstrated that the cham-ber movements far exceed the long-term drift tolerance specified for the APS Upgrade MBA storage ring.« less
Llauradó, Elisabet; Aceves-Martins, Magaly; Tarro, Lucia; Papell-Garcia, Ignasi; Puiggròs, Francesc; Prades-Tena, Jordi; Kettner, Helle; Arola, Lluis; Giralt, Montse; Solà, Rosa
2018-02-10
Sustainability capacity, always considered a challenge, is the ability to maintain effective long-term intervention in a community. The aim of the study was to improve the sustainability capacity of effective "Som la Pera," a school-based, peer-led, social-marketing intervention that encourages healthy diet and physical activity, in low socioeconomic adolescents from Spain. The sustainability capacity was analyzed by a "programme sustainability assessment tool (PSAT)" comprising eight domains: political support, funding stability, partnerships, organizational capacity, programme evaluation, programme adaptation, communications, and strategic planning. Each domain was evaluated from 1 (no or to a small extent) to 7 points (to a great extent). The final score for sustainability capacity was the mean of the eight domain scores. The PSAT was assessed by nine professionals (researchers, staff members, and stakeholders) at two periods during intervention implementation: end of the first year (January 2015) and end of the second year (September 2015). At the end of the first year, strategic planning (4.43 ± 1.98) and funding stability (4.38 ± 1) were considered deficient domains, and at the end of the second year, these domains had improved by 1.67 points (p =.043) and 0.59 points (p = .159), respectively. The funding stability increase was not significant because only one of the five specific items, "policies implemented to ensure sustained funding," improved by 1.08 points (p = .036). The sustainability capacity final score was 5.93 ± 1.13. The sustainability capacity assessment during the intervention allows its improvement before the programme expires, ensuring the long-term implementation of the "Som la Pera" intervention programme to encourage healthy lifestyles in adolescents. © Society of Behavioral Medicine 2018. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Long-Term Stability of the SGA-WZ Strapdown Airborne Gravimeter
Cai, Shaokun; Zhang, Kaidong; Wu, Meiping; Huang, Yangming
2012-01-01
Accelerometers are one of the most important sensors in a strapdown airborne gravimeter. The accelerometer's drift determines the long-term accuracy of the strapdown inertial navigation system (SINS), which is the primary and most critical component of the strapdown airborne gravimeter. A long-term stability test lasting 104 days was conducted to determine the characteristics of the strapdown airborne gravimeter's long-term drift. This stability test was based on the first set of strapdown airborne gravimeters built in China, the SGA-WZ. The test results reveal a quadratic drift in the strapdown airborne gravimeter data. A drift model was developed using the static data in the two end sections, and then this model was used to correct the test data. After compensating for the drift, the drift effect improved from 70 mGal to 3.46 mGal with a standard deviation of 0.63 mGal. The quadratic curve better reflects the drift's real characteristics. In comparison with other methodologies, modelling the drift as a quadratic curve was shown to be more appropriate. Furthermore, this method allows the drift to be adjusted throughout the course of the entire campaign. PMID:23112647
Long-Acting Phospholipid Gel of Exenatide for Long-Term Therapy of Type II Diabetes.
Hu, Mei; Zhang, Yu; Xiang, Nanxi; Zhong, Ying; Gong, Tao; Zhang, Zhi-Rong; Fu, Yao
2016-06-01
This study aimed to develop a sustained-release formulation of exenatide (EXT) for the long-term therapeutic efficacy in the treatment of type II diabetes. In this study, we present an injectable phospholipid gel by mixing biocompatible phospholipid S100, medium chain triglyceride (MCT) with 85% (w/w) ethanol. A systemic pre-formulation study has been carried out to improve the stability of EXT during formulation fabrication. With the optimized formulation, the pharmacokinetic profiles in rats were studied and two diabetic animal models were employed to evaluate the therapeutic effect of EXT phospholipid gel via a single subcutaneous injection versus repeated injections of normal saline and EXT solution. With optimized formulation, sustained release of exenatide in vivo for over three consecutive weeks was observed after one single subcutaneous injection. Moreover, the pharmacodynamic study in two diabetic models justified that the gel formulation displayed a comparable hypoglycemic effect and controlled blood glucose level compared with exenatide solution treated group. EXT-loaded phospholipid gel represents a promising controlled release system for long-term therapy of type II diabetes.
Stability of drugs of abuse in urine samples stored at -20 degrees C.
Dugan, S; Bogema, S; Schwartz, R W; Lappas, N T
1994-01-01
Isolated studies of the stability of individual drugs of abuse have been reported. However, few have evaluated stability in frozen urine samples stored for 12 months. We have determined the stability of 11-nor-9-carboxy-delta 9-tetrahydrocannabinol (9-COOH-THC), amphetamine, methamphetamine, morphine, codeine, cocaine, benzoylecgonine, and phencyclidine in 236 physiological urine samples. Following the initial quantitative analysis, the samples were stored at -20 degrees C for 12 months and then reanalyzed. All drug concentrations were determined by gas chromatographic-mass spectrometric methods with cutoff concentrations of 5 ng/mL for 9-COOH-THC and phencyclidine and 100 ng/mL for each of the other drugs. The average change in the concentrations of these drugs following this long-term storage was not extensive except for an average change of -37% in cocaine concentrations.
Zhukov, V A; Kokorev, S V; Rogozhkina, S V; Melnikov, D G; Terentiev, A I; Kovalchuk, E A; Vakhnov, E Yu; Borisevich, S V
2016-01-01
Determination of values of coefficients of thermal stability of TEOVac for prognosis of conservation of the vaccine (specific biological activity) during the process of warranty period storage. TEOVac (masticatory tablets) in primary packaging was kept at increased temperature (accelerated and stress-tests) and at the conditions established by PAP for the preparation (long-term tests). Biological activity of the vaccine was determined by titration on 12-day chicken embryos. A correlation between the value of coefficients of thermal stability and conservation of the prepared series of the condition preparation at the final date of storage was experimentally established. Coefficients of thermal stability could be used as a prognostic indicator of quality of the produced pelleted formulation of the preparation for evaluation of conservation of the vaccine during warranty period storage.
Cover design for radioactive and AMD-producing mine waste in the Ronneburg area, eastern Thuringia.
Gatzweiler, R; Jahn, S; Neubert, G; Paul, M
2001-01-01
At the former uranium mining site of Ronneburg, large scale underground and open pit mining for nearly 40 years resulted in a production of about 113,000 tonnes of uranium and about 200 million cubic metres of mine waste. In their present state, these materials cause risks to human health and strong environmental impacts and therefore demand remedial action. The remediation options available are relocation of mine spoil into the open pit and on site remediation by landscaping/contouring, placement of a cover and revegetation. A suitable vegetated cover system combined with a surface water drainage system provides long-term stability against erosion and reduces acid generation thereby meeting the main remediation objectives which are long-term reduction of radiological exposure and contaminant emissions and recultivation. The design of the cover system includes the evaluation of geotechnical, radiological, hydrological, geochemical and ecological criteria and models. The optimized overall model for the cover system has to comply with general conditions as, e.g. economic efficiency, public acceptance and sustainability. Most critical elements for the long-term performance of the cover system designed for the Beerwalde dump are the barrier system and its long-term integrity and a largely self-sustainable vegetation.
Frequency standard stability for Doppler measurements on-board the shuttle
NASA Technical Reports Server (NTRS)
Harton, P. L.
1974-01-01
The short and long term stability characteristics of crystal and atomic standards are described. Emphasis is placed on crystal oscillators because of the selection which was made for the shuttle baseline and the complexities which are introduced by the shuttle environment. Attention is given, first, to the definitions of stability and the application of these definitions to the shuttle system and its mission. Data from time domain measurements are used to illustrate the definitions. Results of a literature survey to determine environmental effects on frequency reference sources are then presented. Finally, methods of standard frequency dissemination over radio frequency carriers are noted as a possible means of measuring absolute accuracy and long term stability characteristics during on one way Doppler equipment.
Chen, Qun-Feng; Troshyn, Andrei; Ernsting, Ingo; Kayser, Steffen; Vasilyev, Sergey; Nevsky, Alexander; Schiller, Stephan
2011-11-25
Using an ultrastable continuous-wave laser at 580 nm we performed spectral hole burning of Eu(3+):Y(2)SiO(5) at a very high spectral resolution. The essential parameters determining the usefulness as a macroscopic frequency reference, linewidth, temperature sensitivity, and long-term stability, were characterized using a H-maser stabilized frequency comb. Spectral holes with a linewidth as low as 6 kHz were observed and the upper limit of the drift of the hole frequency was determined to be 5±3 mHz/s. We discuss the necessary requirements for achieving ultrahigh stability in laser frequency stabilization to these spectral holes.
ERIC Educational Resources Information Center
Bauer, Patricia J.; Larkina, Marina; Doydum, Ayzit O.
2012-01-01
Long-term recall is influenced by what originally was encoded as well as by the efficacy of retrieval processes. The possible explanatory role of post-encoding processes by which initially labile memory traces are stabilized and integrated into long-term memory (i.e., consolidated) has received relatively less research attention. In the current…
Co-disposal of electronic waste with municipal solid waste in bioreactor landfills.
Visvanathan, C; Visvanthan, C; Yin, Nang Htay; Karthikeyan, Obuli P
2010-12-01
Three pilot scale lysimeters were adopted to evaluate the stability pattern and leaching potential of heavy metals from MSW landfills under the E-waste co-disposed condition. One lysimeter served as control and solely filled with MSW, whereas the other two lysimeters were provided with 10% and 25% of E-waste scraps (% by weight), respectively. The reactors were monitored over a period of 280 days at ambient settings with continuous leachate recirculation. Stabilization pattern of carbon appears to be more than 50% in all the three lysimeters with irrespective of their operating conditions. Iron and zinc concentrations were high in leachate during bioreactor landfill operation and correlating with the TCLP leachability test results. In contrast, Pb concentration was around <0.6 mg/L, but which showed maximum leaching potential under TCLP test conditions. But, no heavy metal accumulation was found with leachate recirculation practices in lysimeters. Mobility of the metal content from the E-waste was found to be amplified with the long term disposal or stabilization within landfills. The results showed that the TCLP test cannot be completely reliable tool for measuring long-term leachability of toxic substances under landfill condition; rather landfill lysimeter studies are necessary to get the real scenario. Copyright © 2010 Elsevier Ltd. All rights reserved.
Stabilization of dynamics of oscillatory systems by nonautonomous perturbation.
Lucas, Maxime; Newman, Julian; Stefanovska, Aneta
2018-04-01
Synchronization and stability under periodic oscillatory driving are well understood, but little is known about the effects of aperiodic driving, despite its abundance in nature. Here, we consider oscillators subject to driving with slowly varying frequency, and investigate both short-term and long-term stability properties. For a phase oscillator, we find that, counterintuitively, such variation is guaranteed to enlarge the Arnold tongue in parameter space. Using analytical and numerical methods that provide information on time-variable dynamical properties, we find that the growth of the Arnold tongue is specifically due to the growth of a region of intermittent synchronization where trajectories alternate between short-term stability and short-term neutral stability, giving rise to stability on average. We also present examples of higher-dimensional nonlinear oscillators where a similar stabilization phenomenon is numerically observed. Our findings help support the case that in general, deterministic nonautonomous perturbation is a very good candidate for stabilizing complex dynamics.
Stabilization of dynamics of oscillatory systems by nonautonomous perturbation
NASA Astrophysics Data System (ADS)
Lucas, Maxime; Newman, Julian; Stefanovska, Aneta
2018-04-01
Synchronization and stability under periodic oscillatory driving are well understood, but little is known about the effects of aperiodic driving, despite its abundance in nature. Here, we consider oscillators subject to driving with slowly varying frequency, and investigate both short-term and long-term stability properties. For a phase oscillator, we find that, counterintuitively, such variation is guaranteed to enlarge the Arnold tongue in parameter space. Using analytical and numerical methods that provide information on time-variable dynamical properties, we find that the growth of the Arnold tongue is specifically due to the growth of a region of intermittent synchronization where trajectories alternate between short-term stability and short-term neutral stability, giving rise to stability on average. We also present examples of higher-dimensional nonlinear oscillators where a similar stabilization phenomenon is numerically observed. Our findings help support the case that in general, deterministic nonautonomous perturbation is a very good candidate for stabilizing complex dynamics.
Becker, Ina; Strauch, Sebastian M; Hauslage, Jens; Lebert, Michael
2017-05-01
The unicellular freshwater flagellate Euglena gracilis has a highly developed sensory system. The cells use different stimuli such as light and gravity to orient themselves in the surrounding medium to find areas for optimal growth. Due to the ability to produce oxygen and consume carbon dioxide, Euglena is a suitable candidate for life support systems. Participation in a long-term space experiment would allow for the analysis of changes and adaptations to the new environment, and this could bring new insights into the mechanism of perception of gravity and the associated signal transduction chain. For a molecular analysis of transcription patterns, an automated system is necessary, capable of performing all steps from taking a sample, processing it and generating data. One of the developmental steps is to find long-term stable reagents and materials and test them for stability at higher-than-recommended temperature conditions during extended storage time. We investigated the usability of magnetic beads in an Euglena specific lysis buffer after addition of the RNA stabilizer Dithiothreitol over 360 days and the lysis buffer with the stabilizer alone over 455 days at the expected storage temperature of 19 °C. We can claim that the stability is not impaired at all after an incubation period of over one year. This might be an interesting result for researchers who have to work under non-standard lab conditions, as in biological or medicinal fieldwork. Copyright © 2017 The Committee on Space Research (COSPAR). Published by Elsevier Ltd. All rights reserved.
Multimodal frontostriatal connectivity underlies individual differences in self-esteem
Heatherton, Todd F.
2015-01-01
A heightened sense of self-esteem is associated with a reduced risk for several types of affective and psychiatric disorders, including depression, anxiety and eating disorders. However, little is known about how brain systems integrate self-referential processing and positive evaluation to give rise to these feelings. To address this, we combined diffusion tensor imaging (DTI) and functional magnetic resonance imaging (fMRI) to test how frontostriatal connectivity reflects long-term trait and short-term state aspects of self-esteem. Using DTI, we found individual variability in white matter structural integrity between the medial prefrontal cortex and the ventral striatum was related to trait measures of self-esteem, reflecting long-term stability of self-esteem maintenance. Using fMRI, we found that functional connectivity of these regions during positive self-evaluation was related to current feelings of self-esteem, reflecting short-term state self-esteem. These results provide convergent anatomical and functional evidence that self-esteem is related to the connectivity of frontostriatal circuits and suggest that feelings of self-worth may emerge from neural systems integrating information about the self with positive affect and reward. This information could potentially inform the etiology of diminished self-esteem underlying multiple psychiatric conditions and inform future studies of evaluative self-referential processing. PMID:24795440
Autonomous System for MISSE Temperature Measurements
NASA Technical Reports Server (NTRS)
Harvey, G. A.; Lash, T. J.; Kinard, W. H.; Bull, K.; deGeest, F.
2001-01-01
The Materials International Space Station Experiment (MISSE) is scheduled to be deployed during the summer of 2001. This experiment is a cooperative endeavor by NASA-LaRC, NASA-GRC, NASA MSFC, NASA-JSC, the Materials Laboratory at the Air Force Research Laboratory, and the Boeing Phantom Works. The objective of the experiment is to evaluate performance, stability, and long term survivability of materials and components planned for use by NASA and DOD on future LEO, synchronous orbit, and interplanetary space missions. Temperature is an important parameter in the evaluation of space environmental effects on materials.
Long-Term Biostability of Self-Assembling Protein Polymers in the Absence of Covalent Crosslinking
Sallach, Rory E.; Cui, Wanxing; Balderrama, Fanor; Martinez, Adam W.; Wen, Jing; Haller, Carolyn A.; Taylor, Jeannette V.; Wright, Elizabeth R.; Long, Robert C.; Chaikof, Elliot L.
2009-01-01
Unless chemically crosslinked, matrix proteins, such as collagen or silk, display a limited lifetime in vivo with significant degradation observed over a period of weeks. Likewise, amphiphilic peptides, lipopeptides, or glycolipids that self-assemble through hydrophobic interactions to form thin films, fiber networks, or vesicles do not demonstrate in vivo biostability beyond a few days. We report herein that a self-assembling, recombinant elastin-mimetic triblock copolymer elicited minimal inflammatory response and displayed robust in vivo stability for periods exceeding 1 year, in the absence of either chemical or ionic crosslinking. Specifically, neither a significant inflammatory response nor calcification was observed upon implantation of test materials into the peritoneal cavity or subcutaneous space of a mouse model. Moreover, serial quantitative magnetic resonance imaging, evaluation of pre- and post-explant ultrastructure by cryo-high resolution scanning electron microscopy, and an examination of implant mechanical responses revealed substantial preservation of form, material architecture, and biomechanical properties, providing convincing evidence of a non-chemically or ionically crosslinked protein polymer system that exhibits long-term stability in vivo. PMID:19854505
NASA Astrophysics Data System (ADS)
Murugan, Rajasekaran; Kumar, Sanjay
2015-04-01
Soil aggregate stability is a crucial soil property that affects soil biota, biogeochemical processes and C sequestration. The relationship between soil aggregate stability and soil C cycling is well known but the influence of specific fungal community structure on this relationship is largely unknown in paddy soils. The aim of the present study was to evaluate the long-term fertilisation (mineral fertiliser-MIN; farmyard manure-FYM; groundnut oil cake-GOC) effects on soil fungal community shifts associated with soil aggregates under rice-monoculture (RRR) and rice-legume-rice (RLR) systems. Fungal and bacterial communities were characterized using phospholipid fatty acids, and glucosamine and muramic acid were used as biomarkers for fungal and bacterial residues, respectively. Microbial biomass C and N, fungal biomass and residues were significantly higher in the organic fertiliser treatments than in the MIN treatment, for all aggregate sizes under both crop rotation systems. In general, fungal/bacterial biomass ratio and fungal residue C/bacterial residue C ratio were significantly higher in macroaggregate fractions (> 2000 and 250-2000 μm) than in microaggregate fractions (53-250 and <53 μm). In both crop rotation systems, the long-term application of FYM and GOC led to increased accumulation of saprotrophic fungi (SF) in aggregate fractions > 2000 μm. In contrast, we found that arbuscular mycorrhizal fungi (AMF) was surprisingly higher in aggregate fractions > 2000 μm than in aggregate fraction 250-2000 μm under MIN treatment. The RLR system showed significantly higher AMF biomass and fungal residue C/ bacterial residue C ratio in both macroaggregate fractions compared to the RRR system. The strong relationships between SF, AMF and water stable aggregates shows the specific contribution of fungi community on soil aggregate stability. Our results highlight the fact that changes within fungal community structure play an important role in shaping the soil aggregate stability and C sequestration in tropical agricultural ecosystems.
Long-term stability of crystal-stabilized water-in-oil emulsions.
Ghosh, Supratim; Pradhan, Mamata; Patel, Tejas; Haj-Shafiei, Samira; Rousseau, Dérick
2015-12-15
The impact of cooling rate and mixing on the long-term kinetic stability of wax-stabilized water-in-oil emulsions was investigated. Four cooling/mixing protocols were investigated: cooling from 45°C to either 25°C or 4°C with/without stirring and two cooling rates - slow (1°C/min) and fast (5°C/min). The sedimentation behaviour of the emulsions was significantly affected by cooling protocol. Stirring was critical to the stability of all emulsions, with statically-cooled (no stirring) emulsions suffering from extensive aqueous phase separation. Emulsions stirred while cooling showed sedimentation of a waxy emulsion layer leaving a clear oil layer at the top, with a smaller separation and droplet size distribution at 4°C compared to 25°C, indicating the importance of the amount of crystallized wax on emulsion stability. Light microscopy revealed that crystallized wax appeared both on the droplet surface and in the continuous phase, suggesting that stirring ensured dispersibility of the water droplets during cooling as the wax was crystallizing. Wax crystallization on the droplet surface provided stability against droplet coalescence while continuous phase wax crystals minimized inter-droplet collisions. The key novel aspect of this research is in the simplicity to tailor the spatial distribution of wax crystals, i.e., either at the droplet surface or in the continuous phase via use of a surfactant and judicious stirring and/or cooling. Knowledge gained from this research can be applied to develop strategies for long-term storage stability of crystal-stabilized W/O emulsions. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Wood, Peter C.; Wydeven, Theodore
1987-01-01
The removal of CO2 from the NASA Space Station's cabin atmosphere, which may be undertaken by a solid-amine water (steam)-desorbed system, is presently evaluated with a view to long-term amine resin stability and adsorption/desorption cycling by means of an automated laboratory flow-testing facility. While the CO2-adsorption capacity of the IRA-45 amine resin used gradually decreased over time, the rate of degradation significantly decreased after the first 10 cycles. Attention is given to the presence (and possible need for removal) of trimethylamine in the process air downstream of the resin bed.
On the long-term stability of calibration standards in different matrices.
Kandić, A; Vukanac, I; Djurašević, M; Novković, D; Šešlak, B; Milošević, Z
2012-09-01
In order to assure Quality Control in accordance with ISO/IEC 17025, it was important, from metrological point of view, to examine the long-term stability of calibration standards previously prepared. Comprehensive reconsideration on efficiency curves with respect to the ageing of calibration standards is presented in this paper. The calibration standards were re-used after a period of 5 years and analysis of the results showed discrepancies in efficiency values. Copyright © 2012 Elsevier Ltd. All rights reserved.
Louwe, R J W; Tielenburg, R; van Ingen, K M; Mijnheer, B J; van Herk, M B
2004-04-01
This study was performed to determine the stability of liquid-filled matrix ionization chamber (LiFi-type) electronic portal imaging devices (EPID) for dosimetric purposes. The short- and long-term stability of the response was investigated, as well as the importance of factors influencing the response (e.g., temperature fluctuations, radiation damage, and the performance of the electronic hardware). It was shown that testing the performance of the electronic hardware as well as the short-term stability of the imagers may reveal the cause of a poor long-term stability of the imager response. In addition, the short-term stability was measured to verify the validity of the fitted dose-response curve immediately after beam startup. The long-term stability of these imagers could be considerably improved by correcting for room temperature fluctuations and gradual changes in response due to radiation damage. As a result, the reproducibility was better than 1% (1 SD) over a period of two years. The results of this study were used to formulate recommendations for a quality control program for portal dosimetry. The effect of such a program was assessed by comparing the results of portal dosimetry and in vivo dosimetry using diodes during the treatment of 31 prostate patients. The improvement of the results for portal dosimetry was consistent with the deviations observed with the reproducibility tests in that particular period. After a correction for the variation in response of the imager, the average difference between the measured and prescribed dose during the treatment of prostate patients was -0.7%+/-1.5% (1 SD), and -0.6%+/-1.1% (1 SD) for EPID and diode in vivo dosimetry, respectively. It can be concluded that a high stability of the response can be achieved for this type of EPID by applying a rigorous quality control program.
Sasaki, Hitoshi; Kikuchi, Jun; Maeda, Terutoshi; Kuboniwa, Hitoshi
2010-01-01
The purpose of this study was to evaluate the effect of moisture permeability of different elastomer formulation stoppers, which had different moisture absorption abilities, on the increase of moisture content inside lyophilized vials during long-term storage under humid conditions. Two different elastomer formulation stoppers (high-moisture and low-moisture uptake stoppers) were compared. The increased amount of moisture content inside lyophilized vials fitted with high-moisture stoppers was higher than those fitted with low-moisture stoppers during the early stage of storage. However, this trend was reversed during the later stage of storage. Our data show that the moisture increase inside the lyophilized vials at the early stage was caused by moisture transfer from the stoppers, whereas the later moisture increase was caused by external moisture permeation through the stoppers. Results indicate that the difference in the moisture uptake profile inside the lyophilized vials at each period of storage was caused by the moisture absorption ability and moisture permeation ability of the two elastomer formulation stoppers. In terms of long-term storage stability under humid conditions, our data indicate that external moisture permeating through the stopper into the lyophilized vial during the late stage was the more important factor. In addition, the increase in moisture content at the early stage was controlled by stopper drying time. Furthermore, stopper drying time did not have an effect on moisture permeation at the late stage. Moisture permeation during the storage period appears to be dependent on the different elastomer formulations of the stoppers. The moisture permeation of different elastomer stoppers was an important factor in terms of the increased moisture content inside the lyophilized vials during the late stage of long-term storage under humid conditions. For lyophilized products stored at room temperature, the moisture permeation ability of the stopper is one of the most important factors for long-term storage stability.
Angal, Amit; Xiong, Xiaoxiong; Choi, Tae-young; Chander, Gyanesh; Wu, Aisheng
2010-01-01
Remote sensing imagery is effective for monitoring environmental and climatic changes because of the extent of the global coverage and long time scale of the observations. Radiometric calibration of remote sensing sensors is essential for quantitative & qualitative science and applications. Pseudo-invariant ground targets have been extensively used to monitor the long-term radiometric calibration stability of remote sensing sensors. This paper focuses on the use of the Sonoran Desert site to monitor the radiometric stability of the Landsat 7 (L7) Enhanced Thematic Mapper Plus (ETM+) and Terra Moderate Resolution Imaging Spectroradiometer (MODIS) sensors. The results are compared with the widely used Libya 4 Desert site in an attempt to evaluate the suitability of the Sonoran Desert site for sensor inter-comparison and calibration stability monitoring. Since the overpass times of ETM+ and MODIS differ by about 30 minutes, the impacts due to different view geometries or test site Bi-directional Reflectance Distribution Function (BRDF) are also presented. In general, the long-term drifts in the visible bands are relatively large compared to the drift in the near-infrared bands of both sensors. The lifetime Top-of-Atmosphere (TOA) reflectance trends from both sensors over 10 years are extremely stable, changing by no more than 0.1% per year (except ETM+ Band 1 and MODIS Band 3) over the two sites used for the study. The use of a semi-empirical BRDF model can reduce the impacts due to view geometries, thus enabling a better estimate of sensor temporal drifts.
Li, Jingwei; Wei, Bo; Cao, Zhiqun; Yue, Xing; Zhang, Yaxin; Lü, Zhe
2018-01-10
The Nb-doped lanthanum strontium ferrite perovskite oxide La 0.8 Sr 0.2 Fe 0.9 Nb 0.1 O 3-δ (LSFNb) is evaluated as an anode material in a solid oxide fuel cell (SOFC). The effects of Nb partial substitution in the crystal structure, the electrical conductivity, and the valence of Fe ions are studied. LSFNb exhibits good structural stability in a severe reducing atmosphere at 800 °C, suggesting that high-valent Nb can effectively promote the stability of the lattice structure. The concentration of Fe 2+ increases after Nb doping, as confirmed by X-ray photoelectron spectroscopy. The maximum power density of a thick Sc-stabilized zirconia (ScSZ) electrolyte-supported single cell reached 241.6 mW cm -2 at 800 °C with H 2 as fuel. The cell exhibited excellent stability for 100 h continuous operation without detectable degeneration. Scanning electron microscopy clearly revealed exsolution on the LSFNb surface after operation. Meanwhile, LSFNb particles agglomerated significantly during long-term stability testing. Impedance spectra suggested that both the LSFNb anode and the (La 0.75 Sr 0.25 ) 0.95 MnO 3-δ /ScSZ cathode underwent an activation process during long-term testing, through which the charge transfer ability increased significantly. Meanwhile, low-frequency resistance (R L ) mainly attributed to the anode (80 %) significantly increased, probably due to the agglomeration of LSFNb particles. The LSFNb anode exhibits excellent anti-sulfuring poisoning ability and redox stability. These results demonstrate that LSFNb is a promising anode material for SOFCs. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Humidity-corrected Arrhenius equation: The reference condition approach.
Naveršnik, Klemen; Jurečič, Rok
2016-03-16
Accelerated and stress stability data is often used to predict shelf life of pharmaceuticals. Temperature, combined with humidity accelerates chemical decomposition and the Arrhenius equation is used to extrapolate accelerated stability results to long-term stability. Statistical estimation of the humidity-corrected Arrhenius equation is not straightforward due to its non-linearity. A two stage nonlinear fitting approach is used in practice, followed by a prediction stage. We developed a single-stage statistical procedure, called the reference condition approach, which has better statistical properties (less collinearity, direct estimation of uncertainty, narrower prediction interval) and is significantly easier to use, compared to the existing approaches. Our statistical model was populated with data from a 35-day stress stability study on a laboratory batch of vitamin tablets and required mere 30 laboratory assay determinations. The stability prediction agreed well with the actual 24-month long term stability of the product. The approach has high potential to assist product formulation, specification setting and stability statements. Copyright © 2016 Elsevier B.V. All rights reserved.
3D printed cellular solid outperforms traditional stochastic foam in long-term mechanical response
Maiti, A.; Small, W.; Lewicki, J.; ...
2016-04-27
3D printing of polymeric foams by direct-ink-write is a recent technological breakthrough that enables the creation of versatile compressible solids with programmable microstructure, customizable shapes, and tunable mechanical response including negative elastic modulus. However, in many applications the success of these 3D printed materials as a viable replacement for traditional stochastic foams critically depends on their mechanical performance and micro-architectural stability while deployed under long-term mechanical strain. To predict the long-term performance of the two types of foams we employed multi-year-long accelerated aging studies under compressive strain followed by a time-temperature-superposition analysis using a minimum-arc-length-based algorithm. The resulting master curvesmore » predict superior long-term performance of the 3D printed foam in terms of two different metrics, i.e., compression set and load retention. To gain deeper understanding, we imaged the microstructure of both foams using X-ray computed tomography, and performed finite-element analysis of the mechanical response within these microstructures. As a result, this indicates a wider stress variation in the stochastic foam with points of more extreme local stress as compared to the 3D printed material, which might explain the latter’s improved long-term stability and mechanical performance.« less
3D printed cellular solid outperforms traditional stochastic foam in long-term mechanical response
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maiti, A.; Small, W.; Lewicki, J.
3D printing of polymeric foams by direct-ink-write is a recent technological breakthrough that enables the creation of versatile compressible solids with programmable microstructure, customizable shapes, and tunable mechanical response including negative elastic modulus. However, in many applications the success of these 3D printed materials as a viable replacement for traditional stochastic foams critically depends on their mechanical performance and micro-architectural stability while deployed under long-term mechanical strain. To predict the long-term performance of the two types of foams we employed multi-year-long accelerated aging studies under compressive strain followed by a time-temperature-superposition analysis using a minimum-arc-length-based algorithm. The resulting master curvesmore » predict superior long-term performance of the 3D printed foam in terms of two different metrics, i.e., compression set and load retention. To gain deeper understanding, we imaged the microstructure of both foams using X-ray computed tomography, and performed finite-element analysis of the mechanical response within these microstructures. As a result, this indicates a wider stress variation in the stochastic foam with points of more extreme local stress as compared to the 3D printed material, which might explain the latter’s improved long-term stability and mechanical performance.« less
3D printed cellular solid outperforms traditional stochastic foam in long-term mechanical response
NASA Astrophysics Data System (ADS)
Maiti, A.; Small, W.; Lewicki, J. P.; Weisgraber, T. H.; Duoss, E. B.; Chinn, S. C.; Pearson, M. A.; Spadaccini, C. M.; Maxwell, R. S.; Wilson, T. S.
2016-04-01
3D printing of polymeric foams by direct-ink-write is a recent technological breakthrough that enables the creation of versatile compressible solids with programmable microstructure, customizable shapes, and tunable mechanical response including negative elastic modulus. However, in many applications the success of these 3D printed materials as a viable replacement for traditional stochastic foams critically depends on their mechanical performance and micro-architectural stability while deployed under long-term mechanical strain. To predict the long-term performance of the two types of foams we employed multi-year-long accelerated aging studies under compressive strain followed by a time-temperature-superposition analysis using a minimum-arc-length-based algorithm. The resulting master curves predict superior long-term performance of the 3D printed foam in terms of two different metrics, i.e., compression set and load retention. To gain deeper understanding, we imaged the microstructure of both foams using X-ray computed tomography, and performed finite-element analysis of the mechanical response within these microstructures. This indicates a wider stress variation in the stochastic foam with points of more extreme local stress as compared to the 3D printed material, which might explain the latter’s improved long-term stability and mechanical performance.
3D printed cellular solid outperforms traditional stochastic foam in long-term mechanical response
Maiti, A.; Small, W.; Lewicki, J. P.; Weisgraber, T. H.; Duoss, E. B.; Chinn, S. C.; Pearson, M. A.; Spadaccini, C. M.; Maxwell, R. S.; Wilson, T. S.
2016-01-01
3D printing of polymeric foams by direct-ink-write is a recent technological breakthrough that enables the creation of versatile compressible solids with programmable microstructure, customizable shapes, and tunable mechanical response including negative elastic modulus. However, in many applications the success of these 3D printed materials as a viable replacement for traditional stochastic foams critically depends on their mechanical performance and micro-architectural stability while deployed under long-term mechanical strain. To predict the long-term performance of the two types of foams we employed multi-year-long accelerated aging studies under compressive strain followed by a time-temperature-superposition analysis using a minimum-arc-length-based algorithm. The resulting master curves predict superior long-term performance of the 3D printed foam in terms of two different metrics, i.e., compression set and load retention. To gain deeper understanding, we imaged the microstructure of both foams using X-ray computed tomography, and performed finite-element analysis of the mechanical response within these microstructures. This indicates a wider stress variation in the stochastic foam with points of more extreme local stress as compared to the 3D printed material, which might explain the latter’s improved long-term stability and mechanical performance. PMID:27117858
Selecting the Best Graphite for Long-Life, High-Energy Li-Ion Batteries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mao, Chengyu; Wood, Marissa; David, Lamuel Abraham
Here, most lithium-ion batteries still rely on intercalation-type graphite materials for anodes, so it is important to consider their role in full cells for applications in electric vehicles. Here, we systematically evaluate the chemical and physical properties of six commercially-available natural and synthetic graphites to establish which factors have the greatest impact on the cycling stability of full cells with nickel-rich LiNi0.8Mn0.1Co0.1O2 (NMC811) cathodes. Electrochemical data and post-mortem characterization explain the origin of capacity fade. The NMC811 cathode shows large irreversible capacity loss and impedance growth, accounting for much of full cell degradation. However, six graphite anodes demonstrate significant differencesmore » with respect to structural change, surface area, impedance growth, and SEI chemistry, which impact overall capacity retention. We found long cycle life correlated most strongly with stable graphite crystallite size. In addition, graphites with lower surface area generally had higher coulombic efficiencies during formation cycles, which led to more stable long-term cycling. The best graphite screened here enables a capacity retention around 90% in full pouch cells over extensive long-term cycling compared to only 82% for cells with the lowest performing graphite. The results show that optimal graphite selection improves cycling stability of high energy lithium-ion cells.« less
Selecting the Best Graphite for Long-Life, High-Energy Li-Ion Batteries
Mao, Chengyu; Wood, Marissa; David, Lamuel Abraham; ...
2018-06-16
Here, most lithium-ion batteries still rely on intercalation-type graphite materials for anodes, so it is important to consider their role in full cells for applications in electric vehicles. Here, we systematically evaluate the chemical and physical properties of six commercially-available natural and synthetic graphites to establish which factors have the greatest impact on the cycling stability of full cells with nickel-rich LiNi0.8Mn0.1Co0.1O2 (NMC811) cathodes. Electrochemical data and post-mortem characterization explain the origin of capacity fade. The NMC811 cathode shows large irreversible capacity loss and impedance growth, accounting for much of full cell degradation. However, six graphite anodes demonstrate significant differencesmore » with respect to structural change, surface area, impedance growth, and SEI chemistry, which impact overall capacity retention. We found long cycle life correlated most strongly with stable graphite crystallite size. In addition, graphites with lower surface area generally had higher coulombic efficiencies during formation cycles, which led to more stable long-term cycling. The best graphite screened here enables a capacity retention around 90% in full pouch cells over extensive long-term cycling compared to only 82% for cells with the lowest performing graphite. The results show that optimal graphite selection improves cycling stability of high energy lithium-ion cells.« less
NASA Technical Reports Server (NTRS)
Burt, Eric A.; Tjoelker, R. L.
2007-01-01
A recent long-term comparison between the compensated multi-pole Linear Ion Trap Standard (LITS) and the laser-cooled primary standards via GPS carrier phase time transfer showed a deviation of less than 2.7x10(exp -17)/day. A subsequent evaluation of potential drift contributors in the LITS showed that the leading candidates are fluctuations in background gases and the neon buffer gas. The current vacuum system employs a "flow-through" turbomolecular pump and a diaphragm fore pump. Here we consider the viability of a "sealed" vacuum system pumped by a non-evaporable getter for long-term ultra-stable clock operation. Initial tests suggests that both further stability improvement and longer mean-time-between-maintenance can be achieved using this approach
Schumacher, Joseph E.; Wallace, Dennis; Vuchinich, Rudy; Mennemeyer, Stephen T.; Kertesz, Stefan G.
2010-01-01
Objectives. We examined whether cocaine-dependent homeless persons had stable housing and were employed 6, 12, and 18 months after they entered a randomized controlled trial comparing 2 treatments. Methods. One group (n = 103) received abstinence-contingent housing, vocational training, and work; another group (n = 103) received the same intervention plus cognitive behavioral day treatment. We examined baseline and early treatment variables for association with long-term housing and employment. Results. Although the enhanced-treatment group achieved better abstinence rates, the groups did not differ in long-term housing and employment stability. However, consecutive weeks of abstinence during treatment (and to a lesser extent, older age and male gender) predicted long-term housing and employment stability after adjustment for baseline differences in employment, housing, and treatment. Conclusions. Our data showed a relationship of abstinence with housing stability. Contrasting these results with the increasingly popular Housing First interventions reveals important gaps in our knowledge to be addressed in future research. PMID:19833998
Long-term efficient organic photovoltaics based on quaternary bulk heterojunctions
NASA Astrophysics Data System (ADS)
Nam, Minwoo; Cha, Minjeong; Lee, Hyun Hwi; Hur, Kahyun; Lee, Kyu-Tae; Yoo, Jaehong; Han, Il Ki; Kwon, S. Joon; Ko, Doo-Hyun
2017-01-01
A major impediment to the commercialization of organic photovoltaics (OPVs) is attaining long-term morphological stability of the bulk heterojunction (BHJ) layer. To secure the stability while pursuing optimized performance, multi-component BHJ-based OPVs have been strategically explored. Here we demonstrate the use of quaternary BHJs (q-BHJs) composed of two conjugated polymer donors and two fullerene acceptors as a novel platform to produce high-efficiency and long-term durable OPVs. A q-BHJ OPV (q-OPV) with an experimentally optimized composition exhibits an enhanced efficiency and extended operational lifetime than does the binary reference OPV. The q-OPV would retain more than 72% of its initial efficiency (for example, 8.42-6.06%) after a 1-year operation at an elevated temperature of 65 °C. This is superior to those of the state-of-the-art BHJ-based OPVs. We attribute the enhanced stability to the significant suppression of domain growth and phase separation between the components via kinetic trapping effect.
Choi, Woosung; Min, Kyungmin; Kim, Chaehoon; Ko, Young Soo; Jeon, Jae Wan; Seo, Hwimin; Park, Yong-Ki; Choi, Minkee
2016-01-01
Amine-containing adsorbents have been extensively investigated for post-combustion carbon dioxide capture due to their ability to chemisorb low-concentration carbon dioxide from a wet flue gas. However, earlier studies have focused primarily on the carbon dioxide uptake of adsorbents, and have not demonstrated effective adsorbent regeneration and long-term stability under such conditions. Here, we report the versatile and scalable synthesis of a functionalized-polyethyleneimine (PEI)/silica adsorbent which simultaneously exhibits a large working capacity (2.2 mmol g−1) and long-term stability in a practical temperature swing adsorption process (regeneration under 100% carbon dioxide at 120 °C), enabling the separation of concentrated carbon dioxide. We demonstrate that the functionalization of PEI with 1,2-epoxybutane reduces the heat of adsorption and facilitates carbon dioxide desorption (>99%) during regeneration compared with unmodified PEI (76%). Moreover, the functionalization significantly improves long-term adsorbent stability over repeated temperature swing adsorption cycles due to the suppression of urea formation and oxidative amine degradation. PMID:27572662
Yamamoto, Manabu; Taguchi, Kenichi; Yamanaka, Takeharu; Matsuyama, Ayumi; Yoshinaga, Keiji; Tsutsui, Shinichi; Ishida, Teruyoshi
2013-03-01
In the decade after the 1945 atomic bombing of Hiroshima, a high incidence of leukemia was observed among atomic bomb survivors. However, the incidence of other cancers gradually increased, while that of leukemia decreased after this period. We evaluated the clinical outcome of early gastric cancer and microsatellite stability over a long-term period in atomic bomb survivors. The results of surgical treatment for early gastric cancer were reviewed for 117 atomic bomb survivors and 394 control patients between 1995 and 2006. In addition, immunohistochemical staining for hMSH2 and hMLH1 expression was performed to evaluate the status of microsatellite stability in 57 atomic bomb survivors and 82 control patients. The long-term survival rate for early gastric cancer in atomic bomb survivors was significantly lower than that in control patients (p < 0.01). Multivariable analysis revealed that age and sex were significant and independent prognostic factors for early gastric cancer. Defective hMSH2 and/or hMLH1 expression was also significantly higher in survivors than in control patients (p < 0.001). Logistic regression analysis revealed that atomic bomb survivorship was related to defective hMSH2 and/or hMLH1 expression. The prognosis of early gastric cancer in atomic bomb survivors was poor and was related to age and sex, rather than to being an atomic bomb survivor. Furthermore, a higher rate of defective hMSH2 and/or hMLH1 expression was observed in the survivors.
Ackermann, Günter; Kirschner, Michael; Guggenbühl, Lisa; Abel, Bettina; Klohn, Axel; Mattig, Thomas
2015-01-01
Aims Since 2007, Health Promotion Switzerland has implemented a national priority program for a healthy body weight. This article provides insight into the methodological challenges and results of the program evaluation. Methods Evaluation of the long-term program required targeted monitoring and evaluation projects addressing different outcome levels. The evaluation was carried out according to the Swiss Model for Outcome Classification (SMOC), a model designed to classify the effects of health promotion and prevention efforts. Results The results presented in this article emphasize both content and methods. The national program successfully achieved outcomes on many different levels within complex societal structures. The evaluation system built around the SMOC enabled assessment of program progress and the development of key indicators. However, it is not possible to determine definitively to what extent the national program helped stabilize the prevalence of obesity in Switzerland. Conclusion The model has shown its utility in providing a basis for evaluation and monitoring of the national program. Continuous analysis of data from evaluation and monitoring has made it possible to check the plausibility of suspected causal relationships as well as to establish an overall perspective and assessment of effectiveness supported by a growing body of evidence. PMID:25765161
Long-Term Stability of Core Language Skill in Children with Contrasting Language Skills
Bornstein, Marc H.; Hahn, Chun-Shin; Putnick, Diane L.
2016-01-01
This four-wave longitudinal study evaluated stability of core language skill in 421 European American and African American children, half of whom were identified as low (n = 201) and half of whom were average-to-high (n = 220) in later language skill. Structural equation modeling supported loadings of multivariate age-appropriate multisource measures of child language on single latent variables of core language skill at 15 and 25 months and 5 and 11 years. Significant stability coefficients were obtained between language latent variables for children of low and average-to-high language skill, even accounting for child positive social interaction and nonverbal intelligence, maternal education and language, and family home environment. Prospects for children with different language skills and intervention implications are discussed. PMID:26998572
The effect of accelerated aging on the wear of UHMWPE.
Sakoda, H; Fisher, J; Lu, S; Buchanan, F
2001-01-01
Oxidative degradation of UHMWPE has been found to be a cause of elevated wear rate of the polymer in total joint replacement leading to failure of these devices. In order to evaluate long term stability of polymers, various accelerated aging methods have been developed. In this study, wear rates of shelf aged UHMWPE and "accelerated aged" UHMWPE were compared using a multi-directional pin-on-plate wear test machine in order to evaluate the effect of the accelerated aging on wear. Wear factors of the aged materials were found to depend on their density, which is a measure of oxidation level. Finally, accelerated aging was calibrated against shelf aging in terms of wear rate. Copyright 2001 Kluwer Academic Publishers
Lárraga-Gutiérrez, José Manuel; García-Garduño, Olivia Amanda; Treviño-Palacios, Carlos; Herrera-González, José Alfredo
2018-03-01
Flatbed scanners are the most frequently used reading instrument for radiochromic film dosimetry because its low cost, high spatial resolution, among other advantages. These scanners use a fluorescent lamp and a CCD array as light source and detector, respectively. Recently, manufacturers of flatbed scanners replaced the fluorescent lamp by light emission diodes (LED) as a light source. The goal of this work is to evaluate the performance of a commercial flatbed scanner with LED based source light for radiochromic film dosimetry. Film read out consistency, response uniformity, film-scanner sensitivity, long term stability and total dose uncertainty was evaluated. In overall, the performance of the LED flatbed scanner is comparable to that of a cold cathode fluorescent lamp (CCFL). There are important spectral differences between LED and CCFL lamps that results in a higher sensitivity of the LED scanner in the green channel. Total dose uncertainty, film response reproducibility and long-term stability of LED scanner are slightly better than those of the CCFL. However, the LED based scanner has a strong non-uniform response, up to 9%, that must be adequately corrected for radiotherapy dosimetry QA. The differences in light emission spectra between LED and CCFL lamps and its potential impact on film-scanner sensitivity suggest that the design of a dedicated flat-bed scanner with LEDs may improve sensitivity and dose uncertainty in radiochromic film dosimetry. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Nanoparticle-stabilized CO₂ foam for CO₂ EOR application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Ning; Lee, Robert; Yu, Jianjia
The purpose of this project was to develop nanoparticle-stabilized CO₂ foam for CO₂ -EOR application, in which nanoparticles instead of surfactants are used for stabilizing CO₂ foam to improve the CO₂ sweep efficiency and increase oil recovery. The studies included: (1) investigation of CO₂ foam generation nanoparticles, such as silica nanoparticles, and the effects of particle concentration and surface properties, CO₂/brine ratio, brine salinity, pressure, and temperature on foam generation and foam stability; (2) coreflooding tests to understand the nanoparticle-stabilized CO₂ foam for waterflooded residual oil recovery, which include: oil-free coreflooding experiments with nanoparticle-stabilized CO₂ foam to understand the transportationmore » of nanoparticles through the core; measurements of foam stability and CO₂ sweep efficiency under reservoir conditions to investigate temperature and pressure effects on the foam performance and oil recovery as well as the sweep efficiency in different core samples with different rock properties; and (3) long-term coreflooding experiments with the nanoparticle- stabilized CO₂ foam for residual oil recovery. Finally, the technical and economical feasibility of this technology was evaluated.« less
Ampawong, Sumate; Aramwit, Pornanong
2017-09-01
In this study, three kinds of antiseptics which were 0.05% chlorhexidine, 0.2% polyhexamethylene biguanide (PHMB), or 200 ppm silver nanoparticle was introduced to incorporate in the sericin-based scaffold to produce the antimicrobial dressing for the treatment of infected chronic wound. The effects of antiseptic incorporation on the stability, release of sericin, and short-term and long-term (6 months) antimicrobial activity of the sericin dressing against gram-negative and gram-positive bacteria were investigated. We showed that the incorporation of each antiseptic did not have significant effect on the internal morphology (pore size ~ 73-105 μm), elasticity (Young's modulus ~ 200-500 kPa), and the sericin release behavior of the sericin-based dressing. The release of sericin from the dressing was prolonged over 120 h and thereafter. Comparing among three antiseptics, 0.05% chlorhexidine incorporated in the sericin dressing showed the highest immediate and long-term (6 months) antimicrobial effect (largest inhibition zone) against most bacteria either gram-positive or gram-negative bacteria. The in vivo safety test following ISO10993 standard (Biological evaluation of medical devices - Part 6: Tests for local effects after implantation) confirmed that the sericin dressing incorporating 0.05% chlorhexidine did not irritate to tissue, comparing with the commercial material used generally in clinic (Allevyn®, Smith & Nephew). We suggested the sericin dressing incorporating 0.05% chlorhexidine for the treatment of infected chronic wound. Chlorhexidine would reduce the risk of infection while the sericin may promote wound healing.
Effects of rigid fixation on the growing neurocranium of immature rabbits.
Sanus, Galip Zihni; Tanriverdi, Taner; Kacira, Tibet; Jackson, Ian T
2007-03-01
The improved intraoperative long-term skeletal stability achieved with rigid fixation techniques has led to their widespread popularity and application. However, experimental studies have revealed some drawbacks related to metallic implants and long-term results of clinical studies, especially in pediatric patients, has confirmed the results of experimental studies. Our aim in this experimental study using an infant rabbit model is to answer the following question: "Does short-term skeletal stability cause long-term growth inhibition?" Forty, 9-day-old New Zealand white albino rabbits were divided into four groups: 1) experimental, n=6: plated across the right coronal suture and two screws on each side of the left coronal suture; 2) re-operation, n=6: the same materials as group I were placed, and only the plate was removed at the end of 1 month; 3) sham, n=6: sham control with simulated surgery and two screws on each side of the left coronal suture; 4) control, n=2: no operation. The animals were killed 6 months after microplate application, and the skulls were evaluated both grossly and cephalometrically. Gross examination showed that the plates and the screws were covered by bony overgrowth and caused bony irregularity and regional bone degeneration. The parietal bones on the plated sides became striated and lost their concave shape. Cephalometric analysis demonstrated overt mastoid tip deviation toward, or shortening of cranionasal length on, the side with rigid fixation. We conclude from our study that rigid fixation during skeletal development causes growth retardation and should not be used in the growing child.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillips, Mark C.; Craig, Ian M.
2013-11-03
We analyze the long-term performance and stability of a trace-gas sensor based on an external cavity quantum cascade laser using data collected over a one-year period in a building air monitoring application.
Riley, Jeffrey W.; Jacobson, Robert B.
2009-01-01
This report presents the data used to assess geomorphic adjustment of streams over time and to changing land-use conditions. Thirty-seven U.S. Geological Survey streamgages were selected within the Piedmont physiographic region of Georgia. Width, depth, stage, and discharge data from these streams were analyzed to assess channel stability and determine if systematic adjustments of channel morphology could be related to time or land use and land cover. Residual analyses of stage-discharge data were used to infer channel stability, which could then be used as an indicator of habitat stability. Streamgages, representing a gradient of urbanization, were selected to test hypotheses regarding stream stability and adjustment to urban conditions. Results indicate that 14 sites exhibited long-term channel stability, 11 were degrading, 6 were aggrading, and 6 showed variability in response over the study period.
NASA Astrophysics Data System (ADS)
Magilligan, F. J.; Goldstien, P.
2011-12-01
River restoration projects with the goal of restoring a wide range of morphologic and ecologic channel processes and functions have become common. The complex interactions between flow and sediment-transport make it challenging to design river channels that are both self-sustaining and improve ecosystem function. The relative immaturity of the field of river restoration and shortcomings in existing methodologies for evaluating channel designs contribute to this problem, often leading to project failures. The call for increased monitoring of constructed channels to evaluate which restoration techniques do and do not work is ubiquitous and may lead to improved channel restoration projects. However, an alternative approach is to detect project flaws before the channels are built by using numerical models to simulate hydraulic and sediment-transport processes and habitat in the proposed channel (Restoration Design Analysis). Multi-dimensional models provide spatially distributed quantities throughout the project domain that may be used to quantitatively evaluate restoration designs for such important metrics as (1) the change in water-surface elevation which can affect the extent and duration of floodplain reconnection, (2) sediment-transport and morphologic change which can affect the channel stability and long-term maintenance of the design; and (3) habitat changes. These models also provide an efficient way to evaluate such quantities over a range of appropriate discharges including low-probability events which often prove the greatest risk to the long-term stability of restored channels. Currently there are many free and open-source modeling frameworks available for such analysis including iRIC, Delft3D, and TELEMAC. In this presentation we give examples of Restoration Design Analysis for each of the metrics above from projects on the Russian River, CA and the Kootenai River, ID. These examples demonstrate how detailed Restoration Design Analysis can be used to guide design elements and how this method can point out potential stability problems or other risks before designs proceed to the construction phase.
The use of multi-dimensional flow and morphodynamic models for restoration design analysis
NASA Astrophysics Data System (ADS)
McDonald, R.; Nelson, J. M.
2013-12-01
River restoration projects with the goal of restoring a wide range of morphologic and ecologic channel processes and functions have become common. The complex interactions between flow and sediment-transport make it challenging to design river channels that are both self-sustaining and improve ecosystem function. The relative immaturity of the field of river restoration and shortcomings in existing methodologies for evaluating channel designs contribute to this problem, often leading to project failures. The call for increased monitoring of constructed channels to evaluate which restoration techniques do and do not work is ubiquitous and may lead to improved channel restoration projects. However, an alternative approach is to detect project flaws before the channels are built by using numerical models to simulate hydraulic and sediment-transport processes and habitat in the proposed channel (Restoration Design Analysis). Multi-dimensional models provide spatially distributed quantities throughout the project domain that may be used to quantitatively evaluate restoration designs for such important metrics as (1) the change in water-surface elevation which can affect the extent and duration of floodplain reconnection, (2) sediment-transport and morphologic change which can affect the channel stability and long-term maintenance of the design; and (3) habitat changes. These models also provide an efficient way to evaluate such quantities over a range of appropriate discharges including low-probability events which often prove the greatest risk to the long-term stability of restored channels. Currently there are many free and open-source modeling frameworks available for such analysis including iRIC, Delft3D, and TELEMAC. In this presentation we give examples of Restoration Design Analysis for each of the metrics above from projects on the Russian River, CA and the Kootenai River, ID. These examples demonstrate how detailed Restoration Design Analysis can be used to guide design elements and how this method can point out potential stability problems or other risks before designs proceed to the construction phase.
Zha, Xue-Qiang; Luo, Jian-Ping
2008-01-01
In this study, the production stability of active polysaccharides in protocorm-like bodies (PLBs) induced from the seedling segments of Dendrobium huoshanense C. Z. Tang et S. J. Cheng was investigated during long-term subculture. Subcultures were conducted once every 30 days. With an average inoculum of 39 g/L fresh PLBs, the increase in biomass ranged from 95.7 g/L to 103.9 g/L in fresh weight and 3.2 g/L to 3.4 g/L in dry weight during eighteen continuous subcultures while polysaccharide content in PLBs was from 0.8 mg/g Fw (mg polysaccharide per gram PLBs in fresh weight) to 1.0 mg/g Fw. In addition, polysaccharides from all cultures showed a similar potential of stimulating interferon gamma (IFN-gamma) release in the supernatant of splenocytes and tumor necrosis factor alpha (TNF-alpha) release in the supernatant of peritoneal macrophages. To elucidate the genetic basis of polysaccharide production stability in long-term subculture of PLBs, the genetic fingerprints by RAPD were further analyzed using plantlets from PLB development. Results showed that there is no evidence of genetic variation both within the plantlets from the different subcultures of PLBs and between long-term subcultures and the donor plants.
Chuah, Yon Jin; Koh, Yi Ting; Lim, Kaiyang; Menon, Nishanth V.; Wu, Yingnan; Kang, Yuejun
2015-01-01
Polydimethylsiloxane (PDMS) has been extensively exploited to study stem cell physiology in the field of mechanobiology and microfluidic chips due to their transparency, low cost and ease of fabrication. However, its intrinsic high hydrophobicity renders a surface incompatible for prolonged cell adhesion and proliferation. Plasma-treated or protein-coated PDMS shows some improvement but these strategies are often short-lived with either cell aggregates formation or cell sheet dissociation. Recently, chemical functionalization of PDMS surfaces has proved to be able to stabilize long-term culture but the chemicals and procedures involved are not user- and eco-friendly. Herein, we aim to tailor greener and biocompatible PDMS surfaces by developing a one-step bio-inspired polydopamine coating strategy to stabilize long-term bone marrow stromal cell culture on PDMS substrates. Characterization of the polydopamine-coated PDMS surfaces has revealed changes in surface wettability and presence of hydroxyl and secondary amines as compared to uncoated surfaces. These changes in PDMS surface profile contribute to the stability in BMSCs adhesion, proliferation and multipotency. This simple methodology can significantly enhance the biocompatibility of PDMS-based microfluidic devices for long-term cell analysis or mechanobiological studies. PMID:26647719
Long term stability of nanowire nanoelectronics in physiological environments.
Zhou, Wei; Dai, Xiaochuan; Fu, Tian-Ming; Xie, Chong; Liu, Jia; Lieber, Charles M
2014-03-12
Nanowire nanoelectronic devices have been exploited as highly sensitive subcellular resolution detectors for recording extracellular and intracellular signals from cells, as well as from natural and engineered/cyborg tissues, and in this capacity open many opportunities for fundamental biological research and biomedical applications. Here we demonstrate the capability to take full advantage of the attractive capabilities of nanowire nanoelectronic devices for long term physiological studies by passivating the nanowire elements with ultrathin metal oxide shells. Studies of Si and Si/aluminum oxide (Al2O3) core/shell nanowires in physiological solutions at 37 °C demonstrate long-term stability extending for at least 100 days in samples coated with 10 nm thick Al2O3 shells. In addition, investigations of nanowires configured as field-effect transistors (FETs) demonstrate that the Si/Al2O3 core/shell nanowire FETs exhibit good device performance for at least 4 months in physiological model solutions at 37 °C. The generality of this approach was also tested with in studies of Ge/Si and InAs nanowires, where Ge/Si/Al2O3 and InAs/Al2O3 core/shell materials exhibited stability for at least 100 days in physiological model solutions at 37 °C. In addition, investigations of hafnium oxide-Al2O3 nanolaminated shells indicate the potential to extend nanowire stability well beyond 1 year time scale in vivo. These studies demonstrate that straightforward core/shell nanowire nanoelectronic devices can exhibit the long term stability needed for a range of chronic in vivo studies in animals as well as powerful biomedical implants that could improve monitoring and treatment of disease.
Long Term Stability of Nanowire Nanoelectronics in Physiological Environments
2015-01-01
Nanowire nanoelectronic devices have been exploited as highly sensitive subcellular resolution detectors for recording extracellular and intracellular signals from cells, as well as from natural and engineered/cyborg tissues, and in this capacity open many opportunities for fundamental biological research and biomedical applications. Here we demonstrate the capability to take full advantage of the attractive capabilities of nanowire nanoelectronic devices for long term physiological studies by passivating the nanowire elements with ultrathin metal oxide shells. Studies of Si and Si/aluminum oxide (Al2O3) core/shell nanowires in physiological solutions at 37 °C demonstrate long-term stability extending for at least 100 days in samples coated with 10 nm thick Al2O3 shells. In addition, investigations of nanowires configured as field-effect transistors (FETs) demonstrate that the Si/Al2O3 core/shell nanowire FETs exhibit good device performance for at least 4 months in physiological model solutions at 37 °C. The generality of this approach was also tested with in studies of Ge/Si and InAs nanowires, where Ge/Si/Al2O3 and InAs/Al2O3 core/shell materials exhibited stability for at least 100 days in physiological model solutions at 37 °C. In addition, investigations of hafnium oxide-Al2O3 nanolaminated shells indicate the potential to extend nanowire stability well beyond 1 year time scale in vivo. These studies demonstrate that straightforward core/shell nanowire nanoelectronic devices can exhibit the long term stability needed for a range of chronic in vivo studies in animals as well as powerful biomedical implants that could improve monitoring and treatment of disease. PMID:24479700
Physical and antimicrobial properties of thyme oil emulsions stabilized by ovalbumin and gum arabic.
Niu, Fuge; Pan, Weichun; Su, Yujie; Yang, Yanjun
2016-12-01
Natural biopolymer stabilized oil-in-water emulsions were formulated using ovalbumin (OVA), gum arabic (GA) solutions and their complexes. The influence of interfacial structure of emulsion (OVA-GA bilayer and OVA/GA complexes emulsions) on the physical properties and antimicrobial activity of thyme oil (TO) emulsion against Escherichia coli (E. coli) was evaluated. The results revealed that the two types of emulsions with different oil phase compositions remained stable during a long storage period. The oil phase composition had an appreciable influence on the mean particle diameter and retention of the TO emulsions. The stable emulsion showed a higher minimum inhibitory concentration (MIC), and the TO emulsions showed an improved long-term antimicrobial activity compared to the pure thyme oil, especially complexes emulsion at pH 4.0. These results provided useful information for developing protection and delivery systems for essential oil using biopolymer. Copyright © 2016 Elsevier Ltd. All rights reserved.
Biomass pyrolysis for biochar or energy applications? A life cycle assessment.
Peters, Jens F; Iribarren, Diego; Dufour, Javier
2015-04-21
The application of biochar as a soil amendment is a potential strategy for carbon sequestration. In this paper, a slow pyrolysis system for generating heat and biochar from lignocellulosic energy crops is simulated and its life-cycle performance compared with that of direct biomass combustion. The use of the char as biochar is also contrasted with alternative use options: cofiring in coal power plants, use as charcoal, and use as a fuel for heat generation. Additionally, the influence on the results of the long-term stability of the biochar in the soil, as well as of biochar effects on biomass yield, is evaluated. Negative greenhouse gas emissions are obtained for the biochar system, indicating a significant carbon abatement potential. However, this is achieved at the expense of lower energy efficiency and higher impacts in the other assessed categories when compared to direct biomass combustion. When comparing the different use options of the pyrolysis char, the most favorable result is obtained for char cofiring substituting fossil coal, even assuming high long-term stability of the char. Nevertheless, a high sensitivity to biomass yield increase is found for biochar systems. In this sense, biochar application to low-quality soils where high yield increases are expected would show a more favorable performance in terms of global warming.
The mechanical stability of polyimide films at high pH
NASA Technical Reports Server (NTRS)
Croall, Catharine I.; St.clair, Terry L.
1990-01-01
Polyimide insulated electrical wire has been widely used in the aerospace industry in commercial, military, and to a lesser degree, general aviation aircraft since the early 1970s. Wiring failures linked to insulation damage have drawn much attention in the media and concerns have developed regarding the long term stability and safety of polyimide insulated electrical wire. The mechanical durability and chemical stability of polyimide insulated wire are affected by hydrolysis, notch propagation, wet and dry arc tracking, topcoat flaking, and degradation due to high pH fluids. Several polyimides were selected for evaluation for resistance to degradation by various aqueous alkaline solutions. The polyimides under evaluation include commercially available films such as KAPTON (tradename), APICAL (tradename), LARC-TPI, and UPILEX (tradename) R and S, as well as a number of experimental films prepared at NASA-Langley. Material properties investigated include viscosity, solubility, moisture absorption, glass transition temperature, dielectric constant, and mechanical properties before and after exposure to various conditions.
Iyer, Vidyashankara; Hu, Lei; Schanté, Carole E; Vance, David; Chadwick, Chrystal; Jain, Nishant Kumar; Brey, Robert N; Joshi, Sangeeta B; Volkin, David B; Andra, Kiran K; Bann, James G; Mantis, Nicholas J; Middaugh, C Russell
2013-11-01
Dominant Negative Inhibitor (DNI) is a translocation-deficient homolog of recombinant protective antigen of Bacillus anthracis that is a candidate for a next generation anthrax vaccine. This study demonstrates that the biophysical characteristics of the DNI protein stored in lyophilized form at 4°C for 8 y were similar to recombinant Protective Antigen (rPA). To provide information on the accelerated stability of DNI, samples in the lyophilized form were subjected to thermal stress (40°C and 70°C for up to 4 weeks) and thoroughly evaluated using various biophysical and chemical characterization techniques. Results demonstrate preserved structural stability of the DNI protein under extreme conditions, suggesting long-term stability can be achieved for a vaccine that employs DNI, as desired for a biodefense countermeasure. Furthermore, the biological activity of the stressed DNI bound to the adjuvant Alhydrogel (®) was evaluated in mice and it was found that the immunogenicity DNI was not affected by thermal stress.
Della-Maggiore, Valeria; Villalta, Jorge I; Kovacevic, Natasa; McIntosh, Anthony Randal
2017-03-01
Adaptation learning is crucial to maintain precise motor control in face of environmental perturbations. Although much progress has been made in understanding the psychophysics and neurophysiology of sensorimotor adaptation (SA), the time course of memory consolidation remains elusive. The lack of a reproducible gradient of memory resistance using protocols of retrograde interference has even led to the proposal that memories produced through SA do not consolidate. Here, we pursued an alternative approach using resting-state fMRI to track changes in functional connectivity (FC) induced by learning. Given that consolidation leads to long-term memory, we hypothesized that a change in FC that predicted long-term memory but not short-term memory would provide indirect evidence for memory stabilization. Six scans were acquired before, 15 min, 1, 3, 5.5, and 24 h after training on a center-out task under veridical or distorted visual feedback. The experimental group showed an increment in FC of a network including motor, premotor, posterior parietal cortex, cerebellum, and putamen that peaked at 5.5 h. Crucially, the strengthening of this network correlated positively with long-term retention but negatively with short-term retention. Our work provides evidence, suggesting that adaptation memories stabilize within a 6-h window, and points to different mechanisms subserving short- and long-term memory. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
NASA Technical Reports Server (NTRS)
Weatherhead, Elizabeth C.; Harder, Jerald; Araujo-Pradere, Eduardo A.; Bodeker, Greg; English, Jason M.; Flynn, Lawrence E.; Frith, Stacey M.; Lazo, Jeffrey K.; Pilewskie, Peter; Weber, Mark;
2017-01-01
Sensors on satellites provide unprecedented understanding of the Earth's climate system by measuring incoming solar radiation, as well as both passive and active observations of the entire Earth with outstanding spatial and temporal coverage. A common challenge with satellite observations is to quantify their ability to provide well-calibrated, long-term, stable records of the parameters they measure. Ground-based intercomparisons offer some insight, while reference observations and internal calibrations give further assistance for understanding long-term stability. A valuable tool for evaluating and developing long-term records from satellites is the examination of data from overlapping satellite missions. This paper addresses how the length of overlap affects the ability to identify an offset or a drift in the overlap of data between two sensors. Ozone and temperature data sets are used as examples showing that overlap data can differ by latitude and can change over time. New results are presented for the general case of sensor overlap by using Solar Radiation and Climate Experiment (SORCE) Spectral Irradiance Monitor (SIM) and Solar Stellar Irradiance Comparison Experiment (SOLSTICE) solar irradiance data as an example. To achieve a 1 % uncertainty in estimating the offset for these two instruments' measurement of the Mg II core (280 nm) requires approximately 5 months of overlap. For relative drift to be identified within 0.1 %/yr uncertainty (0.00008 W/sq m/nm/yr), the overlap for these two satellites would need to be 2.5 years. Additional overlap of satellite measurements is needed if, as is the case for solar monitoring, unexpected jumps occur adding uncertainty to both offsets and drifts; the additional length of time needed to account for a single jump in the overlap data may be as large as 50 % of the original overlap period in order to achieve the same desired confidence in the stability of the merged data set. Results presented here are directly applicable to satellite Earth observations. Approaches for Earth observations offer additional challenges due to the complexity of the observations, but Earth observations may also benefit from ancillary observations taken from ground-based and in situ sources. Difficult choices need to be made when monitoring approaches are considered; we outline some attempts at optimizing networks based on economic principles. The careful evaluation of monitoring overlap is important to the appropriate application of observational resources and to the usefulness of current and future observations.
NASA Astrophysics Data System (ADS)
Weatherhead, Elizabeth C.; Harder, Jerald; Araujo-Pradere, Eduardo A.; Bodeker, Greg; English, Jason M.; Flynn, Lawrence E.; Frith, Stacey M.; Lazo, Jeffrey K.; Pilewskie, Peter; Weber, Mark; Woods, Thomas N.
2017-12-01
Sensors on satellites provide unprecedented understanding of the Earth's climate system by measuring incoming solar radiation, as well as both passive and active observations of the entire Earth with outstanding spatial and temporal coverage. A common challenge with satellite observations is to quantify their ability to provide well-calibrated, long-term, stable records of the parameters they measure. Ground-based intercomparisons offer some insight, while reference observations and internal calibrations give further assistance for understanding long-term stability. A valuable tool for evaluating and developing long-term records from satellites is the examination of data from overlapping satellite missions. This paper addresses how the length of overlap affects the ability to identify an offset or a drift in the overlap of data between two sensors. Ozone and temperature data sets are used as examples showing that overlap data can differ by latitude and can change over time. New results are presented for the general case of sensor overlap by using Solar Radiation and Climate Experiment (SORCE) Spectral Irradiance Monitor (SIM) and Solar Stellar Irradiance Comparison Experiment (SOLSTICE) solar irradiance data as an example. To achieve a 1 % uncertainty in estimating the offset for these two instruments' measurement of the Mg II core (280 nm) requires approximately 5 months of overlap. For relative drift to be identified within 0.1 % yr-1 uncertainty (0.00008 W m-2 nm-1 yr-1), the overlap for these two satellites would need to be 2.5 years. Additional overlap of satellite measurements is needed if, as is the case for solar monitoring, unexpected jumps occur adding uncertainty to both offsets and drifts; the additional length of time needed to account for a single jump in the overlap data may be as large as 50 % of the original overlap period in order to achieve the same desired confidence in the stability of the merged data set. Results presented here are directly applicable to satellite Earth observations. Approaches for Earth observations offer additional challenges due to the complexity of the observations, but Earth observations may also benefit from ancillary observations taken from ground-based and in situ sources. Difficult choices need to be made when monitoring approaches are considered; we outline some attempts at optimizing networks based on economic principles. The careful evaluation of monitoring overlap is important to the appropriate application of observational resources and to the usefulness of current and future observations.
NASA Astrophysics Data System (ADS)
Woo, Ju Yeon; Lee, Jongsoo; Han, Chang-Soo
2013-12-01
The long-term stability of quantum dot (QD)-based devices under harsh environmental conditions has been a critical bottleneck to be resolved for commercial use. Here, we demonstrate an extremely stable QD/alumina/polymer hybrid structure by combining internal atomic layer deposition (ALD) infilling with polymer encapsulation. ALD infilling and polymer encapsulation of QDs synergistically prohibit the degradation of QDs in terms of optical, thermal and humid attacks. Our hybrid QD/alumina/polymer film structure showed no noticeable reduction in photoluminescence even in a commercial grade test (85% humidity at 85 ° C) over 28 days. In addition, we successfully fabricated a QD-based light-emitting device with excellent long-term stability by incorporating hybrid QD/alumina/polymer film as a color conversion material on light-emitting diode chips.
Rokn, A; Bassir, SH; Rasouli Ghahroudi, AA; Kharazifard, MJ; Manesheof, R
2016-01-01
Purpose: The present study aimed to evaluate the long-term stability of esthetic outcomes of soft tissue around maxillary anterior single-tooth implants after 10-to-12 years of loading. Methods: Patients who had been treated for single-tooth implants in the anterior maxilla between February 2000 and July 2002 were invited to participate in the study. All implants had been placed according to delayed implant placement and conventional loading protocols without any connective tissue graft or papilla preservation flaps. Pink Esthetic Score (PES) was rated using standardized clinical photographs to assess the esthetic outcomes of the implant treatment at the time of crown placement and at time of follow-up examination which was at least 10 years after the crown placement. Results: A total of 19 patients were included. The mean score of PES was 11.63 (SD 1.61; range 7-14) at baseline. After 10-to-12 years of function, a mean PES score of 11.05 (SD 2.09; range 6–14) was recorded. No significant differences were found in the esthetic outcomes, categorized based on clinically relevant levels, between the baseline and follow-up session (p>0.05). Conclusion: Within limitation of the present study, it can be concluded that the esthetic outcomes of soft tissue around the maxillary anterior single-tooth implants placed using conventional implant placement technique remained stable in the long-term. PMID:27990185
Jensen, Simon S; Bosshardt, Dieter D; Gruber, Reinhard; Buser, Daniel
2014-11-01
Contour augmentation around early-placed implants (Type 2 placement) using autogenous bone chips combined with deproteinized bovine bone mineral (DBBM) and a collagen barrier membrane has been documented to predictably provide esthetically satisfactory clinical outcomes. In addition, recent data from cone beam computed tomography studies have shown the augmented volume to be stable long-term. However, no human histologic data are available to document the tissue reactions to this bone augmentation procedure. Over an 8-year period, 12 biopsies were harvested 14 to 80 months after implant placement with simultaneous contour augmentation in 10 patients. The biopsies were subjected to histologic and histomorphometric analysis. The biopsies consisted of 32.0% ± 9.6% DBBM particles and 40.6% ± 14.6% mature bone. 70.3% ± 14.5% of the DBBM particle surfaces were covered with bone. On the remaining surface, multinucleated giant cells with varying intensity of tartrate-resistant acid phosphatase staining were regularly present. No signs of inflammation were visible, and no tendency toward a decreasing volume fraction of DBBM over time was observed. The present study confirms previous findings that osseointegrated DBBM particles do not tend to undergo substitution over time. This low substitution rate may be the reason behind the clinically and radiographically documented long-term stability of contour augmentation using a combination of autogenous bone chips, DBBM particles, and a collagen membrane.
Long-Term Effects from Bacterial Meningitis in Childhood and Adolescence on Postural Control
Petersen, Hannes; Patel, Mitesh; Ingason, Einar F.; Einarsson, Einar J.; Haraldsson, Ásgeir; Fransson, Per-Anders
2014-01-01
Bacterial meningitis in childhood is associated with cognitive deficiencies, sensorimotor impairments and motor dysfunction later in life. However, the long-term effects on postural control is largely unknown, e.g., whether meningitis subjects as adults fully can utilize visual information and adaptation to enhance stability. Thirty-six subjects (20 women, mean age 19.3 years) treated in childhood or adolescence for bacterial meningitis, and 25 controls (13 women, mean age 25.1 years) performed posturography with eyes open and closed under unperturbed and perturbed standing. The meningitis subjects were screened for subjective vertigo symptoms using a questionnaire, clinically tested with headshake and head thrust test, as well as their hearing was evaluated. Meningitis subjects were significantly more unstable than controls during unperturbed (p≤0.014) and perturbed standing, though while perturbed only with eyes open in anteroposterior direction (p = 0.034) whereas in lateral direction both with eyes open and closed (p<0.001). Meningitis subjects had poorer adaption ability to balance perturbations especially with eyes open, and they frequently reported symptoms of unsteadiness (88% of the subjects) and dizziness (81%), which was found significantly correlated to objectively decreased stability. Out of the 36 subjects only 3 had unilateral hearing impairment. Hence, survivors of childhood bacterial meningitis may suffer long-term disorders affecting postural control, and would greatly benefit if these common late effects became generally known so treatments can be developed and applied. PMID:25405756
Durham, Julia N; King, John W; Robinson, Quinton C; Trojan, Terry M
2017-03-01
To evaluate and compare the long-term skeletodental stability of mandibular symphyseal distraction osteogenesis (MSDO) achieved with the use of tooth-borne vs. hybrid distraction appliances. Posttreatment and follow-up orthodontic records were collected for 33 patients. The 14 patients who underwent distraction with a tooth-borne appliance had a mean follow-up of 5.08 years. The 19 patients who underwent distraction with a hybrid appliance had a mean follow-up of 6.07 years. Records included intraoral photographs, study models, postero-anterior cephalometric radiographs, and lateral cephalometric radiographs. Total changes of 16 measurements were analyzed to compare patients who underwent the tooth-borne vs. the hybrid distraction. Both groups shared several similar and significant (P < .05) changes from posttreatment to follow-up records. Cast analysis showed a decrease in intercanine width and arch length and an increase in irregularity index. The postero-anterior cephalometric radiograph showed an increase in the width of the interincisal apices. The lateral cephalometric radiograph showed a decrease in the MP-L1 angle. The only statistically significant difference between the two appliances was the intercentral incisor contact point. Changes found are consistent with those found in untreated and orthodontically treated individuals over time. The long-term changes in the current patient sample can be determined to be expected and acceptable. MSDO is a viable treatment option with the use of either a hybrid or tooth-borne appliance.
Danylov, A A; Light, A R; Waldman, J; Erickson, N
2015-12-10
Measurements of the frequency stability of a far-infrared molecular laser have been made by mixing the harmonic of an ultrastable microwave source with a portion of the laser output signal in a terahertz (THz) Schottky diode balanced mixer. A 3 GHz difference-frequency signal was used in a frequency discriminator circuit to lock the laser to the microwave source. Comparisons of the short- and long-term laser frequency stability under free-running and locked conditions show a significant improvement with locking. Short-term frequency jitter was reduced by an order of magnitude, from approximately 40 to 4 kHz, and long-term drift was reduced by more than three orders of magnitude, from approximately 250 kHz to 80 Hz. The results, enabled by the efficient Schottky diode balanced mixer downconverter, demonstrate that ultrastable microwave-based frequency stabilization of THz optically pumped lasers (OPLs) will now be possible at frequencies extending well above 4.0 THz.
Tailored interfaces of unencapsulated perovskite solar cells for >1,000 hour operational stability
Christians, Jeffrey A.; Schulz, Philip; Tinkham, Jonathan S.; ...
2017-11-28
Long-term device stability is the most pressing issue that impedes perovskite solar cell commercialization, given the achieved 22.7% efficiency. The perovskite absorber material itself has been heavily scrutinized for being prone to degradation by water, oxygen and ultraviolet light. To date, most reports characterize device stability in the absence of these extrinsic factors. Here we show that, even under the combined stresses of light (including ultraviolet light), oxygen and moisture, perovskite solar cells can retain 94% of peak efficiency despite 1,000 hours of continuous unencapsulated operation in ambient air conditions (relative humidity of 10-20%). Each interface and contact layer throughoutmore » the device stack plays an important role in the overall stability which, when appropriately modified, yields devices in which both the initial rapid decay (often termed burn-in) and the gradual slower decay are suppressed. This extensively modified device architecture and the understanding developed will lead towards durable long-term device performance.« less
Tailored interfaces of unencapsulated perovskite solar cells for >1,000 hour operational stability
NASA Astrophysics Data System (ADS)
Christians, Jeffrey A.; Schulz, Philip; Tinkham, Jonathan S.; Schloemer, Tracy H.; Harvey, Steven P.; Tremolet de Villers, Bertrand J.; Sellinger, Alan; Berry, Joseph J.; Luther, Joseph M.
2018-01-01
Long-term device stability is the most pressing issue that impedes perovskite solar cell commercialization, given the achieved 22.7% efficiency. The perovskite absorber material itself has been heavily scrutinized for being prone to degradation by water, oxygen and ultraviolet light. To date, most reports characterize device stability in the absence of these extrinsic factors. Here we show that, even under the combined stresses of light (including ultraviolet light), oxygen and moisture, perovskite solar cells can retain 94% of peak efficiency despite 1,000 hours of continuous unencapsulated operation in ambient air conditions (relative humidity of 10-20%). Each interface and contact layer throughout the device stack plays an important role in the overall stability which, when appropriately modified, yields devices in which both the initial rapid decay (often termed burn-in) and the gradual slower decay are suppressed. This extensively modified device architecture and the understanding developed will lead towards durable long-term device performance.
Leveraging Venture Capital and Commercial Business: Enhancing Stability Operations
2011-03-24
Economic Stability Operations have emerged as a new element of United States national strategic power. The creation of jobs, through commercial...examine the key strategic factors influencing long-term economic stability following the withdrawal of combat forces. This paper provides a model for
NASA Technical Reports Server (NTRS)
Mu, Qiaozhen; Wu, Aisheng; Xiong, Xiaoxiong; Doelling, David R.; Angal, Amit; Chang, Tiejun; Bhatt, Rajendra
2017-01-01
MODIS reflective solar bands are calibrated on-orbit using a solar diffuser and near-monthly lunar observations. To monitor the performance and effectiveness of the on-orbit calibrations, pseudo-invariant targets such as deep convective clouds (DCCs), Libya-4, and Dome-C are used to track the long-term stability of MODIS Level 1B product. However, the current MODIS operational DCC technique (DCCT) simply uses the criteria set for the 0.65- m band. We optimize several critical DCCT parameters including the 11- micrometer IR-band Brightness Temperature (BT11) threshold for DCC identification, DCC core size and uniformity to help locate DCCs at convection centers, data collection time interval, and probability distribution function (PDF) bin increment for each channel. The mode reflectances corresponding to the PDF peaks are utilized as the DCC reflectances. Results show that the BT11 threshold and time interval are most critical for the Short Wave Infrared (SWIR) bands. The Bidirectional Reflectance Distribution Function model is most effective in reducing the DCC anisotropy for the visible channels. The uniformity filters and PDF bin size have minimal impacts on the visible channels and a larger impact on the SWIR bands. The newly optimized DCCT will be used for future evaluation of MODIS on-orbit calibration by MODIS Characterization Support Team.
Total knee replacement-cementless tibial fixation with screws: 10-year results.
Ersan, Önder; Öztürk, Alper; Çatma, Mehmet Faruk; Ünlü, Serhan; Akdoğan, Mutlu; Ateş, Yalım
2017-12-01
The aim of this study was to evaluate the long term clinical and radiological results of cementless total knee replacement. A total of 51 knees of 49 patients (33 female and 16 male; mean age: 61.6 years (range, 29-66 years)) who underwent TKR surgery with a posterior stabilized hydroxyapatite coated knee implant were included in this study. All of the tibial components were fixed with screws. The HSS scores were examined preoperatively and at the final follow-up. Radiological assessment was performed with Knee Society evaluating and scoring system. Kaplan-Meier survival analysis was performed to rule out the survival of the tibial component. The mean HSS scores were 45.8 (range 38-60) and 88.1 (range 61-93), preoperatively and at the final follow-up respectively. Complete radiological assessment was performed for 48 knees. Lucent lines at the tibial component were observed in 4 patients; one of these patients underwent a revision surgery due to the loosening of the tibial component. The 10-year survival rate of a tibial component was 98%. Cementless total knee replacement has satisfactory long term clinical results. Primary fixation of the tibial component with screws provides adequate stability even in elderly patients with good bone quality. Level IV, Therapeutic study. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.
Xie, Hongtu; Li, Jianwei; Zhang, Bin; Wang, Lianfeng; Wang, Jingkuan; He, Hongbo; Zhang, Xudong
2015-01-01
Glomalin-related soil protein (GRSP) contributes to the formation and maintenance of soil aggregates, it is however remains unclear whether long-term intensive manure amendments alter soil aggregates stability and whether GRSP regulates these changes. Based on a three-decade long fertilization experiment in northeast China, this study examined the impact of long-term manure input on soil organic carbon (SOC), total and easily extractable GRSP (GRSPt and GRSPe) and their respective allocations in four soil aggregates (>2000 μm; 2000–250 μm; 250–53 μm; and <53 μm). The treatments include no fertilization (CK), low and high manure amendment (M1, M2), chemical nitrogen, phosphorus and potassium fertilizers (NPK), and combined manure and chemical fertilizers (NPKM1, NPKM2). Though SOC, GRSPe and GRSPt in soil and SOC in each aggregate generally increased with increasing manure input, GRSPt and GRSPe in each aggregate showed varying changes with manure input. Both GRSP in macroaggregates (2000–250 μm) were significantly higher under low manure input, a pattern consistent with changes in soil aggregate stability. Constituting 38~49% of soil mass, macroaggregates likely contributed to the nonlinear changes of aggregate stability under manure amendments. The regulatory process of GRSP allocations in soil aggregates has important implications for manure management under intensive agriculture. PMID:26423355
Amaladoss, Alfred; Roberts, Nasreen; Amaladoss, Franklin
2010-01-01
Mood stabilizers and anticonvulsants have been frequently used to control behaviors in children and adolescent with nonaffective disorders. The purpose of this study was to review the literature to evaluate the evidence of these agents as treatment options in this subset of patients. We reviewed all the literature between 1949 and 2009 on the use of anticonvulsants and mood stabilizers in controlling severe behavior dysregulation and aggression in child and adolescent who do not meet the criteria for any mood disorder. The review revealed a total of 19 studies. Of the different mood stabilizers/anticonvulsants, both lithium and divalproex showed some promise in treating children and adolescents with nonmood disorders. Larger studies are nevertheless needed to support the ongoing use of these current anticonvulsants and mood stabilizers in children and adolescents with nonmood disorders. Also, further investigation to the potential use in the long term would need to be established, bearing in mind the balance of side effects and treatment benefit.
Long-term actuarial survivorship analysis of an interspinous stabilization system
Sénégas, Jacques; Pointillart, Vincent; Mangione, Paolo
2007-01-01
In 1986, an interspinous dynamic stabilization system (the prototype of the current Wallis implant) was designed to stiffen unstable operated degenerate lumbar segments with a hard interspinous blocker to limit extension and a tension band around the spinous processes to secure the implant and limit flexion. Restoring physiological mechanical conditions to the treated level(s) while preserving some intervertebral mobility was intended to treat low-back pain related to degenerative instability without increasing stress forces in the adjacent segments. The procedure was easily reversible. If low back pain persisted or recurred, the device was removed and stability was achieved using fusion. The intermediate-term results were promising, but the long-term safety and efficacy of this dynamic interspinous stabilization device has not been previously documented. We retrospectively reviewed the hospital files of all the patients (n = 241) who had this dynamic stabilization system implanted between 1987 and 1995, contacting as many as possible to determine the actuarial survivorship of the system. In this manner, 142 of the 241 patients (58.9%) were contacted by telephone. The endpoints used for the survivorship analysis were ‘any subsequent lumbar operation’ and ‘implant removal’. At 14 years follow-up, values of actuarial survivorship with 95% confidence interval were 75.9 ± 8.3 and 81.3 ± 6.8% for the endpoints ‘any subsequent lumbar operation’ and ‘implant removal’, respectively. There was no difference in survivorship of multiple-level implants with respect to single-level devices. Although the conclusions of the present study must be tempered by the 41% attrition rate, these findings support the long-term safety of this system, and possibly long-term protective action against adjacent-level degeneration by motion preservation. Outcomes at least equivalent to those of fusion were observed without the primary drawbacks of fusion. PMID:17426988
Long-Term Dynamics of Autonomous Fractional Differential Equations
NASA Astrophysics Data System (ADS)
Liu, Tao; Xu, Wei; Xu, Yong; Han, Qun
This paper aims to investigate long-term dynamic behaviors of autonomous fractional differential equations with effective numerical method. The long-term dynamic behaviors predict where systems are heading after long-term evolution. We make some modification and transplant cell mapping methods to autonomous fractional differential equations. The mapping time duration of cell mapping is enlarged to deal with the long memory effect. Three illustrative examples, i.e. fractional Lotka-Volterra equation, fractional van der Pol oscillator and fractional Duffing equation, are studied with our revised generalized cell mapping method. We obtain long-term dynamics, such as attractors, basins of attraction, and saddles. Compared with some existing stability and numerical results, the validity of our method is verified. Furthermore, we find that the fractional order has its effect on the long-term dynamics of autonomous fractional differential equations.
[KEEPING THE ELECTRON-DONOR PROPERTIES OF DRINKING WATER].
Gibert, K K; Stekhin, A A; Iakovleva, G V; Sul'ina, Iu S
2015-01-01
In a study there was performed the experimental evaluation of long-term structural--physical changes of the phase of associated water in drinking water treated in hypomagnetic conditions according to the the technology providing the retention of of ortho/para isomers of water in the presence of a catalyst--triplet oxygen. According to the results of measurements ofparameters of nano-associates formed in the water there was found a series ofconsistencies, allowing to determine the mechanisms of the impact of hypomagnetic treatment on the catalytic properties ofwater and long-term stability of its activated state, that provides the long-term maintenance of high biological activity of drinking water. In particular, under hypomagnetic conditions of the treatment there is formed denser packing of amorphous ice--VI in the composition of associates peroxide, serving as a kind of "reservoir" of atmospheric gases. In such a "reservoir" there realized higher pressure, compared with normal geophysical conditions, that stimulates the gas-phase reactions with the formation of dimers and trimers of oxygen existing in the 2-electron--active configurations with binding energies of 0.3 eVand ~0.2 eV providing phase modulation, resulting in condensation of environment additional electrons on paramagnetic oxygen, which provides the long-term maintenance of the electron--donor ability of water and electrically non-equilibrium state.
USDA-ARS?s Scientific Manuscript database
Periodic variability in meteorological patterns presents significant challenges to crop production consistency and yield stability. Meteorological influences on corn and soybean grain yields were analyzed over an 18-year period at a long-term experiment in Beltsville, Maryland, U.S.A., comparing c...
41 CFR 51-6.3 - Long-term procurements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 41 Public Contracts and Property Management 1 2010-07-01 2010-07-01 true Long-term procurements. 51-6.3 Section 51-6.3 Public Contracts and Property Management Other Provisions Relating to Public... ensure stability of employment and development of job skills for persons who are blind or have other...
Paliperidone for the treatment of schizoaffective disorder.
Alphs, Larry; Fu, Dong-Jing; Turkoz, Ibrahim
2016-01-01
Schizoaffective disorder (SCA) is a complex mental illness characterized by psychosis and affective symptoms. Treatment usually involves concomitant therapy with antipsychotics, mood stabilizers, and/or antidepressants. Effective treatment must address acute symptoms, maintain long-term stability, promote recovery, and improve patient functioning. Data from 3 pivotal studies evaluating the acute and maintenance treatment of SCA with paliperidone are reviewed. Two formulations of paliperidone have been studied for these indications: an extended-release oral formulation (NCT00397033, NCT00412373) and long-acting injectable once-monthly paliperidone palmitate (NCT01193153). The reported effects of these formulations on psychotic, depressive, and manic symptoms are discussed. Both formulations were found to be safe and effective for the acute and maintenance treatment of SCA. Of critical importance for this treatment population is that rapid improvement was seen in all major symptoms of SCA, including psychosis, depression, and mania. Mediation analyses suggest that the known antipsychotic effects of paliperidone occur independently of its antidepressant effects. Both formulations of the drug are effective when used as monotherapy or adjunctively with antidepressants or mood stabilizers. Beyond symptom control, both formulations improved patient functioning and increased patient satisfaction.
Development of inexpensive metal macrocyclic complexes for use in fuel cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doddapaneni, N.; Ingersoll, D.; Kosek, J.A.
Several metal macrocyclic complexes were synthesized for use as catalysts in fuel cells. An initial evaluation of their ability to catalyze the fuel cell reactions were completed. Based on this initial evaluation, one metal macrocyclic catalyst was selected and long-term stability testing in a fuel cell was initiated. The fuel cell employing this catalyst was operated continuously for one year with little signs of catalyst degradation. The effect of synthetic reformates on the performance of the catalyst in the fuel cell environment also demonstrated high tolerance of this catalyst for common contaminants and poisons.
Importance of microscopy in durability studies of solidified and stabilized contaminated soils
Klich, I.; Wilding, L.P.; Drees, L.R.; Landa, E.R.
1999-01-01
Solidification/stabilization (S/S) is recognized by the U.S. EPA as a best demonstrated available technology for the containment of contaminated soils and other hazardous wastes that cannot be destroyed by chemical, thermal, or biological means. Despite the increased use of S/S technologies, little research has been conducted on the weathering and degradation of solidified and stabilized wastes once the treated materials have been buried. Published data to verify the performance and durability of landfilled treated wastes over time are rare. In this preliminary study, optical and electron microscopy (scanning electron microscopy [SEM], transmission electron microscopy [TEM] and electron probe microanalyses [EPMA]) were used to evaluate weathering features associated with metal-bearing contaminated soil that had been solidified and stabilized with Portland cement and subsequently buried on site, stored outdoors aboveground, or achieved in a laboratory warehouse for up to 6 yr. Physical and chemical alteration processes identified include: freeze-thaw cracking, cracking caused by the formation of expansive minerals such as ettringite, carbonation, and the movement of metals from waste aggregates into the cement micromass. Although the extent of degradation after 6 yr is considered slight to moderate, results of this study show that the same environmental concerns that affect the durability of concrete must be considered when evaluating the durability and permanence of the solidification and stabilization of contaminated soils with cement. In addition, such evaluations cannot be based on leaching and chemical analyses alone. The use of all levels of microscopic analyses must be incorporated into studies of the long-term performance of S/S technologies.Solidification/stabilization (S/S) is recognized by the U.S. EPA as a best demonstrated available technology for the containment of contaminated soils and other hazardous wastes that cannot be destroyed by chemical, thermal, or biological means. Despite the increased use of S/S technologies, little research has been conducted on the weathering and degradation of solidified and stabilized wastes once the treated materials have been buried. Published data to verify the performance and durability of landfilled treated wastes over time are rare. In this preliminary study, optical and electron microscopy (scanning electron microscopy [SEM], transmission electron microscopy [TEM] and electron probe microanalyses [EPMA]) were used to evaluate weathering features associated with metal-bearing contaminated soil that had been solidified and stabilized with Portland cement and subsequently buried on site, stored outdoors aboveground, or archived in a laboratory, warehouse for up to 6 yr. Physical and chemical alteration processes identified include: freeze-thaw cracking, cracking caused by the formation of expansive minerals such as ettringite, carbonation, and the movement of metals from waste aggregates into the cement micromass. Although the extent of degradation after 6 yr is considered slight to moderate, results of this study show that the same environmental concerns that affect the durability of concrete must be considered when evaluating the durability and permanence of the solidification and stabilization of contaminated soils with cement. In addition, such evaluations cannot be based on leaching and chemical analyses alone. The use of all levels of microscopic analyses must be incorporated into studies of the long-term performance of S/S technologies.
NASA Astrophysics Data System (ADS)
Kempka, Thomas; De Lucia, Marco; Kühn, Michael
2014-05-01
Static and dynamic numerical modelling generally accompany the entire CO2 storage site life cycle. Thereto, it is required to match the employed models with field observations on a regular basis in order to predict future site behaviour. We investigated the coupled processes at the Ketzin CO2 storage pilot site [1] using a model coupling concept focusing on the temporal relevance of processes involved (hydraulic, chemical and mechanical) at given time-scales (site operation, abandonment and long-term stabilization). For that purpose, long-term dynamic multi-phase flow simulations [2], [3] established the basis for all simulations discussed in the following. Hereby, pressure changes resulting in geomechanical effects are largest during site operation, whereas geochemical reactions are governed by slow kinetics resulting in a long-term stabilization. To account for mechanical integrity, which may be mainly affected during site operation, we incorporated a regional-scale coupled hydro-mechanical model. Our simulation results show maximum ground surface displacements of about 4 mm, whereas shear and tensile failure are not observed. Consequently, the CO2 storage operation at the Ketzin pilot site does not compromise reservoir, caprock and fault integrity. Chemical processes responsible for mineral trapping are expected to mainly occur during long-term stabilization at the Ketzin pilot site [4]. Hence, our previous assessment [3] was extended by integrating two long-term mineral trapping scenarios. Thereby, mineral trapping contributes to the trapping mechanisms with 11.7 % after 16,000 years of simulation in our conservative and with 30.9 % in our maximum reactivity scenarios. Dynamic flow simulations indicate that only 0.2 % of the CO2 injected (about 67,270 t CO2 in total) is in gaseous state, but structurally trapped after 16,000 years. Depending on the studied long-term scenario, CO2 dissolution is the dominating trapping mechanism with 68.9 % and 88.1 %, respectively. We verified the mechanical integrity of the storage system during site operation and predicted the trapping mechanisms for the Ketzin pilot site based on a time-dependent integration of relevant processes for a time period of 16,000 years. Supported by our coupled modelling results, we conclude that CO2 storage at the Ketzin site is safe and reliable on the pilot scale. References [1] Martens, S., Kempka, T., Liebscher, A., Lüth, S., Möller, F., Myrttinen, A., Norden, B., Schmidt-Hattenberger, C., Zimmer, M., Kühn, M. Europe's longest-operating on-shore CO2 storage site at Ketzin, Germany: a progress report after three years of injection. Environmental Earth Sciences 2012 67(2): 323-334. [2] Kempka, T., Kühn, M. Numerical simulations of CO2 arrival times and reservoir pressure coincide with observations from the Ketzin pilot site, Germany. Environmental Earth Sciences 2013 70(8): 3675-3685. [3] Kempka, T., Klein, E., De Lucia, M., Tillner, E., Kühn, M. Assessment of Long-term CO2 Trapping Mechanisms at the Ketzin Pilot Site (Germany) by Coupled Numerical Modelling. Energy Procedia 2013 37: 5419-5426. [4] Klein, E., De Lucia, M., Kempka, T., Kühn, M. Evaluation of long-term mineral trapping at the Ketzin pilot site for CO2 storage: An integrative approach using geochemical modelling and reservoir simulation. International Journal of Greenhouse Gas Control 2013 19: 720-730.
Stability of the Medial Olivocochlear Reflex as Measured by Distortion Product Otoacoustic Emissions
Abdala, Carolina
2015-01-01
Purpose The purpose of this study was to assess the repeatability of a fine-resolution, distortion product otoacoustic emission (DPOAE)–based assay of the medial olivocochlear (MOC) reflex in normal-hearing adults. Method Data were collected during 36 test sessions from 4 normal-hearing adults to assess short-term stability and 5 normal-hearing adults to assess long-term stability. DPOAE level and phase measurements were recorded with and without contralateral acoustic stimulation. MOC reflex indices were computed by (a) noting contralateral acoustic stimulation-induced changes in DPOAE level (both absolute and normalized) at fine-structure peaks, (b) recording the effect as a vector difference, and (c) separating DPOAE components and considering a component-specific metric. Results Analyses indicated good repeatability of all indices of the MOC reflex in most frequency ranges. Short- and long-term repeatability were generally comparable. Indices normalized to a subject's own baseline fared best, showing strong short- and long-term stability across all frequency intervals. Conclusions These results suggest that fine-resolution DPOAE-based measures of the MOC reflex measured at strategic frequencies are stable, and natural variance from day-to-day or week-to-week durations is small enough to detect between-group differences and possibly to monitor intervention-related success. However, this is an empirical question that must be directly tested to confirm its utility. PMID:25320951
PD-PK evaluation of freeze-dried atorvastatin calcium-loaded poly-ε-caprolactone nanoparticles.
Ahmed, Iman S; El-Hosary, Rania; Shalaby, Samia; Abd-Rabo, Marwa M; Elkhateeb, Dalia G; Nour, Samia
2016-05-17
In this work lyophilized poly-ε-caprolactone nanoparticles (NPs) loaded with atorvastatin calcium (AC) were developed in an attempt to improve the in-vivo performance of AC following oral administration. The individual and combined effects of several formulation variables were previously investigated using step-wise full factorial designs in order to produce optimized AC-NPs with predetermined characteristics including particle size, drug loading capacity, drug release profile and physical stability. Four optimized formulations were further subjected in this work to lyophilization to promote their long-term physical stability and were fully characterized. The pharmacodynamics (PD)/pharmacokinetics (PK) properties of two optimized freeze-dried AC-NPs formulations showing acceptable long-term stability were determined and compared to a marketed AC immediate release tablet (Lipitor(®)) in albino rats. PD results revealed that the two tested formulations were equally effective in reducing low density lipoproteins (LDL) and triglycerides (TG) levels when given in reduced doses compared to Lipitor(®) and showed no adverse effects. PK results, on the other hand, revealed that the two freeze-dried AC-NPs formulations were of significantly lower bioavailability compared to Lipitor(®). Taken together the PD and PK results demonstrate that the improved efficacy obtained at reduced doses from the freeze-dried AC-NPs could be due to increased concentration of AC in the liver rather than in the plasma. Copyright © 2016 Elsevier B.V. All rights reserved.
Aggregate Stability of Tropical Soils Under Long-Term Eucalyptus Cultivation
USDA-ARS?s Scientific Manuscript database
Eucalyptus cultivation has increased in all Brazilian regions. Despite the large amount of cultivated area, little is known about how this kind of management system affects soil properties, mainly the aggregate stability. Aggregate stability analyses have proved to be a sensitive tool to measure soi...
Long-term stabilization of place cell remapping produced by a fearful experience
Wang, Melissa E.; Wann, Ellen G.; Yuan, Robin K.; Ramos Álvarez, Manuel M.; Stead, Squire M.; Muzzio, Isabel A.
2012-01-01
Fear is an emotional response to danger that is highly conserved throughout evolution because it is critical for survival. Accordingly, episodic memory for fearful locations is widely studied using contextual fear conditioning, a hippocampus-dependent task (Kim and Fanselow, 1992; Phillips and LeDoux, 1992). The hippocampus has been implicated in episodic emotional memory and is thought to integrate emotional stimuli within a spatial framework. Physiological evidence supporting the role of the hippocampus in contextual fear indicates that pyramidal cells in this region, which fire in specific locations as an animal moves through an environment, shift their preferred firing locations shortly after the presentation of an aversive stimulus (Moita et al., 2004). However, the long-term physiological mechanisms through which emotional memories are encoded by the hippocampus are unknown. Here we show that during and directly after a fearful experience, new hippocampal representations are established and persist in the long term. We recorded from the same place cells in mouse hippocampal area CA1 over several days during predator odor contextual fear conditioning and found that a subset of cells changed their preferred firing locations in response to the fearful stimulus. Furthermore, the newly formed representations of the fearful context stabilized in the long term. Our results demonstrate that place cells respond to the presence of an aversive stimulus, modify their firing patterns during emotional learning, and stabilize a long-term spatial representation in response to a fearful encounter. The persistent nature of these representations may contribute to the enduring quality of emotional memories. PMID:23136419
Karatas, Abdullah; Pehlivanoglu, Filiz; Salviz, Mehti; Kuvat, Nuray; Cebi, Isil Taylan; Dikmen, Burak; Sengoz, Gonul
The main reason for nasal tampon placement after septoplasty is to prevent postoperative hemorrhage, while the secondary purpose is internal stabilization after operations involving the cartilaginous-bony skeleton of the nose. Silicone intranasal splints are as successful as other materials in controlling postoperative hemorrhages of septal origin. The possibility of leaving the splints intranasally for extended periods helps stabilize the septum in the midline. However, there is nothing in the literature about how long these splints can be retained inside the nasal cavity without increasing the risk of infection, postoperative complications, and patient discomfort. The current study aimed to evaluate the association between the duration of intranasal splinting and bacterial colonization, postoperative complications, and patient discomfort. Patients who had undergone septoplasty were divided into three groups according to the day of removal of the silicone splints. The splints were removed on the fifth, seventh, and tenth postoperative days. The removed splints were microbiologically cultured. Early and late complications were assessed, including local and systemic infections, tissue necrosis, granuloma formation, mucosal crusting, synechia, and septal perforation. Postoperative patient discomfort was evaluated by scoring the levels of pain and nasal obstruction. No significant difference was found in the rate of bacterial colonization among the different groups. Decreased mucosal crusting and synechia were detected with longer usage intervals of intranasal silicone splints. Postoperative pain and nasal obstruction were also diminished by the third postoperative day. Silicone splints were well tolerated by the patients and any negative effects on postoperative patient comfort were limited. In fact, prolonged splint usage intervals reduced late complications. Long-term silicone nasal splint usage is a reliable, effective, and comfortable method in patients with excessive mucosal damage and in whom long-term stabilization of the bony and cartilaginous septum is essential. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Multimodal frontostriatal connectivity underlies individual differences in self-esteem.
Chavez, Robert S; Heatherton, Todd F
2015-03-01
A heightened sense of self-esteem is associated with a reduced risk for several types of affective and psychiatric disorders, including depression, anxiety and eating disorders. However, little is known about how brain systems integrate self-referential processing and positive evaluation to give rise to these feelings. To address this, we combined diffusion tensor imaging (DTI) and functional magnetic resonance imaging (fMRI) to test how frontostriatal connectivity reflects long-term trait and short-term state aspects of self-esteem. Using DTI, we found individual variability in white matter structural integrity between the medial prefrontal cortex and the ventral striatum was related to trait measures of self-esteem, reflecting long-term stability of self-esteem maintenance. Using fMRI, we found that functional connectivity of these regions during positive self-evaluation was related to current feelings of self-esteem, reflecting short-term state self-esteem. These results provide convergent anatomical and functional evidence that self-esteem is related to the connectivity of frontostriatal circuits and suggest that feelings of self-worth may emerge from neural systems integrating information about the self with positive affect and reward. This information could potentially inform the etiology of diminished self-esteem underlying multiple psychiatric conditions and inform future studies of evaluative self-referential processing. © The Author (2014). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Grise, K. M.; Thompson, D. W.; Birner, T.
2009-12-01
Static stability is a fundamental dynamical quantity that measures the vertical temperature stratification of the atmosphere. The long-term mean static stability field is characterized by the well-known transition from low values in the troposphere to high values in the stratosphere. However, the magnitude and structure of fine-scale static stability features near the tropopause are difficult to discern in temperature data with low vertical resolution. In this study, the authors apply over six years of high vertical resolution Global Positioning System radio occultation temperature profiles to document the long-term mean structure and variability of static stability in the global upper troposphere and lower stratosphere (UTLS). The results of this study demonstrate that a shallow but pronounced maximum in static stability exists just above the tropopause at all latitudes (i.e., the “tropopause inversion layer,” or TIL). This study also uncovers two novel aspects of static stability in the global UTLS. In the tropical lower stratosphere, the results reveal a unique vertically and horizontally varying static stability structure, with maxima located at ~17 km and ~19 km. The upper feature peaks during the NH cold season and has its largest magnitude between 10 and 15 degrees latitude in both hemispheres; the lower feature exhibits a weaker seasonal cycle and is centered at the Equator. The results also demonstrate that the strength of the TIL is closely tied to stratospheric dynamic variability. The magnitude of the TIL is enhanced following sudden stratospheric warmings in the polar regions and the easterly phase of the quasi-biennial oscillation in the tropics.
NASA Astrophysics Data System (ADS)
Grise, Kevin M.; Thompson, David W. J.; Birner, Thomas
2010-05-01
Static stability is a fundamental dynamical quantity that measures the vertical temperature stratification of the atmosphere. The long-term mean static stability field is characterized by the well-known transition from low values in the troposphere to high values in the stratosphere. However, the magnitude and structure of fine-scale static stability features near the tropopause are difficult to discern in temperature data with low vertical resolution. In this study, the authors apply over six years of high vertical resolution Global Positioning System radio occultation temperature profiles to document the long-term mean structure and variability of static stability in the global upper troposphere and lower stratosphere (UTLS). The results of this study demonstrate that a shallow but pronounced maximum in static stability exists just above the tropopause at all latitudes (i.e., the "tropopause inversion layer," or TIL). This study also uncovers two novel aspects of static stability in the global UTLS. In the tropical lower stratosphere, the results reveal a unique vertically and horizontally varying static stability structure, with maxima located at ~17 km and ~19 km. The upper feature peaks during the NH cold season and has its largest magnitude between 10 and 15 degrees latitude in both hemispheres; the lower feature exhibits a weaker seasonal cycle and is centered at the Equator. The results also demonstrate that the strength of the TIL is closely tied to stratospheric dynamic variability. The magnitude of the TIL is enhanced following sudden stratospheric warmings in the polar regions and the easterly phase of the quasi-biennial oscillation in the tropics.
NASA Astrophysics Data System (ADS)
Jeong, Chan-Yong; Kim, Hee-Joong; Hong, Sae-Young; Song, Sang-Hun; Kwon, Hyuck-In
2017-08-01
In this study, we show that the two-stage unified stretched-exponential model can more exactly describe the time-dependence of threshold voltage shift (ΔV TH) under long-term positive-bias-stresses compared to the traditional stretched-exponential model in amorphous indium-gallium-zinc oxide (a-IGZO) thin-film transistors (TFTs). ΔV TH is mainly dominated by electron trapping at short stress times, and the contribution of trap state generation becomes significant with an increase in the stress time. The two-stage unified stretched-exponential model can provide useful information not only for evaluating the long-term electrical stability and lifetime of the a-IGZO TFT but also for understanding the stress-induced degradation mechanism in a-IGZO TFTs.
Hippocampal long term memory: effect of the cholinergic system on local protein synthesis.
Lana, Daniele; Cerbai, Francesca; Di Russo, Jacopo; Boscaro, Francesca; Giannetti, Ambra; Petkova-Kirova, Polina; Pugliese, Anna Maria; Giovannini, Maria Grazia
2013-11-01
The present study was aimed at establishing a link between the cholinergic system and the pathway of mTOR and its downstream effector p70S6K, likely actors in long term memory encoding. We performed in vivo behavioral experiments using the step down inhibitory avoidance test (IA) in adult Wistar rats to evaluate memory formation under different conditions, and immunohistochemistry on hippocampal slices to evaluate the level and the time-course of mTOR and p70S6K activation. We also examined the effect of RAPA, inhibitor of mTORC1 formation, and of the acetylcholine (ACh) muscarinic receptor antagonist scopolamine (SCOP) or ACh nicotinic receptor antagonist mecamylamine (MECA) on short and long term memory formation and on the functionality of the mTOR pathway. Acquisition test was performed 30 min after i.c.v. injection of RAPA, a time sufficient for the drug to diffuse to CA1 pyramidal neurons, as demonstrated by MALDI-TOF-TOF imaging. Recall test was performed 1 h, 4 h or 24 h after acquisition. To confirm our results we performed in vitro experiments on live hippocampal slices: we evaluated whether stimulation of the cholinergic system with the cholinergic receptor agonist carbachol (CCh) activated the mTOR pathway and whether the administration of the above-mentioned antagonists together with CCh could revert this activation. We found that (1) mTOR and p70S6K activation in the hippocampus were involved in long term memory formation; (2) RAPA administration caused inhibition of mTOR activation at 1 h and 4 h and of p70S6K activation at 4 h, and long term memory impairment at 24 h after acquisition; (3) scopolamine treatment caused short but not long term memory impairment with an early increase of mTOR/p70S6K activation at 1 h followed by stabilization at longer times; (4) mecamylamine plus scopolamine treatment caused short term memory impairment at 1 h and 4 h and reduced the scopolamine-induced increase of mTOR/p70S6K activation at 1 h and 4 h; (5) mecamylamine plus scopolamine treatment did not impair long term memory formation; (6) in vitro treatment with carbachol activated mTOR and p70S6K and this effect was blocked by scopolamine and mecamylamine. Taken together our data reinforce the idea that distinct molecular mechanisms are at the basis of the two different forms of memory and are in accordance with data presented by other groups that there exist molecular mechanisms that underlie short term memory, others that underlie long term memories, but some mechanisms are involved in both. Copyright © 2013 Elsevier Inc. All rights reserved.
Kim, Chang Woo; Eom, Tae Young; Yang, In Seok; Kim, Byung Su; Lee, Wan In; Kang, Yong Soo; Kang, Young Soo
2017-07-28
In the present study, a dual-functional smart film combining the effects of wavelength conversion and amplification of the converted wave by the localized surface plasmon resonance has been investigated for a perovskite solar cell. This dual-functional film, composed of Au nanoparticles coated on the surface of Y 2 O 3 :Eu 3+ phosphor (Au@Y 2 O 3 :Eu 3+ ) nanoparticle monolayer, enhances the solar energy conversion efficiency to electrical energy and long-term stability of photovoltaic cells. Coupling between the Y 2 O 3 :Eu 3+ phosphor monolayer and ultraviolet solar light induces the latter to be converted into visible light with a quantum yield above 80%. Concurrently, the Au nanoparticle monolayer on the phosphor nanoparticle monolayer amplifies the converted visible light by up to 170%. This synergy leads to an increased solar light energy conversion efficiency of perovskite solar cells. Simultaneously, the dual-function film suppresses the photodegradation of perovskite by UV light, resulting in long-term stability. Introducing the hybrid smart Au@Y 2 O 3 :Eu 3+ film in perovskite solar cells increases their overall solar-to-electrical energy conversion efficiency to 16.1% and enhances long-term stability, as compared to the value of 15.2% for standard perovskite solar cells. The synergism between the wavelength conversion effect of the phosphor nanoparticle monolayer and the wave amplification by the localized surface plasmon resonance of the Au nanoparticle monolayer in a perovskite solar cell is comparatively investigated, providing a viable strategy of broadening the solar spectrum utilization.
Field Evaluation of Seepage Meters in the Coastal Marine Environment
NASA Astrophysics Data System (ADS)
Cable, J. E.; Burnett, W. C.; Chanton, J. P.; Corbett, D. R.; Cable, P. H.
1997-09-01
The response of seepage meters was evaluated in a nearshore marine environment where water motion effects are more pronounced than in lake settings, where these meters have been used traditionally. Temporal and spatial variations of seepage, as well as potential artifacts, were evaluated using empty and 1000-ml pre-filled bag measurements. Time-series measurements confirmed earlier observations that anomalously high fluxes occur during the early stages (≤10 min) of collection. As deployment times increased (30-60 min), measured flow rates stabilized at a level thought to represent the actual seepage flux. Pre-filling the plastic measurement bags effectively alleviated this anomalous, short-term influx. Reliable seepage measurements required deployment times sufficient to allow a net volume of at least 150 ml into the collection bag. Control experiments, designed by placing seepage meters inside sand-filled plastic swimming pools, served as indicators of external effects on these measurements, i.e. they served as seepage meter blanks. When winds were under 15 knots, little evidence was found that water motion caused artifacts in the seepage measurements. Tidal cycle influences on seepage rates were negligible in the present study area, but long-term temporal variations (weeks to months) proved substantial. Observed long-term changes in groundwater flux into the Gulf of Mexico correlated with water table elevation at a nearby monitoring well.
Cabanas-Valdés, Rosa; Bagur-Calafat, Caritat; Girabent-Farrés, Montserrat; Caballero-Gómez, Fernanda Mª; du Port de Pontcharra-Serra, Helena; German-Romero, Ana; Urrútia, Gerard
2017-11-01
Analyse the effect of core stability exercises in addition to conventional physiotherapy training three months after the intervention ended. A randomized controlled trial. Outpatient services. Seventy-nine stroke survivors. In the intervention period, both groups underwent conventional physiotherapy performed five days/week for five weeks, and in addition the experimental group performed core stability exercises for 15 minutes/day. Afterwards, during a three-month follow-up period, both groups underwent usual care that could eventually include conventional physiotherapy or physical exercise but not in a controlled condition. Primary outcome was trunk control and dynamic sitting balance assessed by the Spanish-Version of Trunk Impairment Scale 2.0 and Function in Sitting Test. Secondary outcomes were standing balance and gait evaluated by the Berg Balance Scale, Tinetti Test, Brunel Balance Assessment, Spanish-Version of Postural Assessment Scale for Stroke and activities of daily living using the Barthel Index. A total of 68 subjects out of 79 completed the three-month follow-up period. The mean difference (SD) between groups was 0.78 (1.51) points ( p = 0.003) for total score on the Spanish-Version of Trunk Impairment Scale 2.0, 2.52 (6.46) points ( p = 0.009) for Function in Sitting Test, dynamic standing balance was 3.30 (9.21) points ( p= 0.009) on the Berg Balance Scale, gait was 0.82 (1.88) points ( p = 0.002) by Brunel Balance Assessment (stepping), and 1.11 (2.94) points ( p = 0.044) by Tinetti Test (gait), all in favour of core stability exercises. Core stability exercises plus conventional physiotherapy have a positive long-term effect on improving dynamic sitting and standing balance and gait in post-stroke patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christians, Jeffrey A.; Schulz, Philip; Tinkham, Jonathan S.
Long-term device stability is the most pressing issue that impedes perovskite solar cell commercialization, given the achieved 22.7% efficiency. The perovskite absorber material itself has been heavily scrutinized for being prone to degradation by water, oxygen and ultraviolet light. To date, most reports characterize device stability in the absence of these extrinsic factors. Here we show that, even under the combined stresses of light (including ultraviolet light), oxygen and moisture, perovskite solar cells can retain 94% of peak efficiency despite 1,000 hours of continuous unencapsulated operation in ambient air conditions (relative humidity of 10-20%). Each interface and contact layer throughoutmore » the device stack plays an important role in the overall stability which, when appropriately modified, yields devices in which both the initial rapid decay (often termed burn-in) and the gradual slower decay are suppressed. This extensively modified device architecture and the understanding developed will lead towards durable long-term device performance.« less
Long-Term Monitoring of Brain Dopamine Metabolism In Vivo with Carbon Paste Electrodes
O'Neill, Robert D.
2005-01-01
This review focuses on the stability of voltammetric signals recorded over periods of months with carbon paste electrodes (CPEs) implanted in the brain. The key interaction underlying this stability is between the pasting oil and brain lipids that are capable of inhibiting the fouling caused by proteins. In brain regions receiving a significant dopaminergic input, a peak due to the methylated metabolites of dopamine, principally homovanillic acid (HVA), is clearly resolved using slow sweep voltammetry. Although a number of factors limit the time resolution for monitoring brain HVA concentration dynamics, the stability of CPEs allows investigations of long-term effects of drugs, as well as behavioral studies, not possible using other in-vivo monitoring techniques.
Evaluation and Validation of Organic Materials for Advanced Stirling Convertors (ASCs): Overview
NASA Technical Reports Server (NTRS)
Shin, Euy-Sik Eugene
2015-01-01
Various organic materials are used as essential parts in Stirling Convertors for their unique properties and functionalities such as bonding, potting, sealing, thread locking, insulation, and lubrication. More efficient Advanced Stirling Convertors (ASC) are being developed for future space applications especially with a long mission cycle, sometimes up to 17 years, such as deep space exploration or lunar surface power or Mars rovers, and others. Thus, performance, durability, and reliability of those organics should be critically evaluated in every possible material-process-fabrication-service environment relations based on their mission specifications. In general, thermal stability, radiation hardness, outgassing, and material compatibility of the selected organics have been systematically evaluated while their process and fabrication conditions and procedures were being optimized. Service environment-simulated long term aging tests up to 4 years were performed as a function of temperature for durability assessment of the most critical organic material systems.
Effects of long-term administration of carprofen on healing of a tibial osteotomy in dogs.
Ochi, Hiroki; Hara, Yasushi; Asou, Yoshinori; Harada, Yasuji; Nezu, Yoshinori; Yogo, Takuya; Shinomiya, Kenichi; Tagawa, Masahiro
2011-05-01
To evaluate effects of long-term administration of carprofen on healing of a tibial osteotomy in dogs. 12 healthy female Beagles. A mid-diaphyseal transverse osteotomy (stabilized with an intramedullary pin) of the right tibia was performed in each dog. The carprofen group (n = 6 dogs) received carprofen (2.2 mg/kg, PO, q 12 h) for 120 days; the control group (6) received no treatment. Bone healing and change in callus area were assessed radiographically over time. Dogs were euthanized 120 days after surgery, and tibiae were evaluated biomechanically and histologically. The osteotomy line was not evident in the control group on radiographs obtained 120 days after surgery. In contrast, the osteotomy line was still evident in the carprofen group. Callus area was significantly less in the carprofen group, compared with the area in the control group, at 20, 30, and 60 days after surgery. At 120 days after surgery, stiffness, elastic modulus, and flexural rigidity in the carprofen group were significantly lower than corresponding values in the control group. Furthermore, histologic evaluation revealed that the cartilage area within the callus in the carprofen group was significantly greater than that in the control group. Long-term administration of carprofen appeared to inhibit bone healing in dogs that underwent tibial osteotomy. We recommend caution for carprofen administration when treating fractures that have delays in healing associated with a reduction in osteogenesis as well as fractures associated with diseases that predispose animals to delays of osseous repair.
Yamane, Mio; Ogawa, Yoko; Fukui, Masaki; Kamoi, Mizuka; Uchino, Miki; Saijo-Ban, Yumiko; Kozuki, Naoyuki; Mukai, Shin; Mori, Takehiko; Okamoto, Shinichiro; Tsubota, Kazuo
2017-12-26
The aim of this study was to assess the safety and efficacy of long-term use of 3% diquafosol ophthalmic solution (DQS), an eye drop for mucin production and water secretion, for treating dry eye disease (DED) caused by chronic graft-versus-host disease (cGVHD). We retrospectively evaluated the safety and efficacy of DQS in 10 patients with mild to moderate cGVHD-induced DED. The efficacy was assessed by (1) degree of symptoms, (2) Schirmer I test value, (3) tear film breakup time (TFBUT), and (4) fluorescein and rose bengal scores. The median duration of DQS treatment was 12.0 months (range 6-17 months). DQS was effective for relieving severe pain caused by cGVHD-related DED. Although the Schirmer I test value was enhanced only marginally, the long-term application of DQS significantly improved the corneal/conjunctival epitheliopathy and tear film stability: the fluorescein score improved from 5.9±0.6 to 1.3±1.1 points (P=1.771×10); rose bengal staining from 4.7±1.6 to 2.0±1.5 points (P=0.008); and TFBUT from 2.6±0.9 to 4.6±1.6 mm (P=0.009). Furthermore, the long-term DQS treatment caused no major adverse events. This study suggested that long-term DQS treatment is a safe and robust approach for alleviating cGVHD-related DED.
Decomposition of heterogeneous organic matterand its long-term stabilization in soils
Sierra, Carlos A.; Harmon, Mark E.; Perakis, Steven S.
2011-01-01
Soil organic matter is a complex mixture of material with heterogeneous biological, physical, and chemical properties. Decomposition models represent this heterogeneity either as a set of discrete pools with different residence times or as a continuum of qualities. It is unclear though, whether these two different approaches yield comparable predictions of organic matter dynamics. Here, we compare predictions from these two different approaches and propose an intermediate approach to study organic matter decomposition based on concepts from continuous models implemented numerically. We found that the disagreement between discrete and continuous approaches can be considerable depending on the degree of nonlinearity of the model and simulation time. The two approaches can diverge substantially for predicting long-term processes in soils. Based on our alternative approach, which is a modification of the continuous quality theory, we explored the temporal patterns that emerge by treating substrate heterogeneity explicitly. The analysis suggests that the pattern of carbon mineralization over time is highly dependent on the degree and form of nonlinearity in the model, mostly expressed as differences in microbial growth and efficiency for different substrates. Moreover, short-term stabilization and destabilization mechanisms operating simultaneously result in long-term accumulation of carbon characterized by low decomposition rates, independent of the characteristics of the incoming litter. We show that representation of heterogeneity in the decomposition process can lead to substantial improvements in our understanding of carbon mineralization and its long-term stability in soils.
ORTHODONTIC RETENTION. Studies of retention capacity, cost-effectiveness and long-term stability.
Tynelius, Gudrun Edman
2014-01-01
Retention strategies, cost-effectiveness and long-term stability of treatment outcome are essential aspects of orthodontic treatment planning. The overall aim of this thesis was to compare and evaluate three different retention strategies, with special reference to short- and long-term clinical stability and cost-effectiveness. The approach was evidence-based, hence randomized controlled methodology was used in order to generate high levels of evidence. This thesis is based on four studies: Papers I and II are based on randomized controlled trials, evaluating the stability of treatment outcome after one and two years of retention, using three different retention strategies: a maxillary vacuum-formed retainer combined with a mandibular canine-to-canine retainer; a maxillary vacuum-formed retainer combined with stripping of the mandibular anterior teeth and a prefabricated positioner. Paper III presents a cost-minimization analysis of two years of retention treatment. Paper IV is based on a randomized controlled trial documenting the results five years post-retention. The following conclusions were drawn: Papers I and II. From a clinical perspective, asssessment after one year of retention disclosed that the three retention methods were successful in retaining the orthodontic treatment results. After two years of retention, all three retention methods were equally effective in controlling relapse at a clinically acceptable level. Most of the relapse occurred during the first year of retention; only minor or negligible changes were found during the second year. The subjects were grouped according to the level of compliance (excellent or good). After two years of retention there was a negative correlation between growth in body height and relapse of mandibular LII in the group of subjects with excellent compliance. The group with good compliance showed a positive correlation (Paper II, Figure 3). After two years of retention, growth in body height, initial crowding and gender had no significant influence on mandibular LII (Paper II, Figure 4 and Table 4). Paper III. The cost minimization analysis disclosed that although the three retention methods achieved clinically similar results, the associated societal costs differed. After two years of retention, the vacuum-formed retainer (VFR) in combination with a canine-to-canine retainer (CTC) was the least cost-effective retention appliance. Paper IV. After five years or more out of retention, the three retention methods had achieved equally favourable clinical results. Key conclusion and clinical implications. This study compared the short- and long-term outcomes of orthodontic retention by three different methods: a maxillary vacuum-formed retainer combined with a mandibular canine-to-canine retainer; a maxillary vacuum-formed retainer combined with stripping of the mandibular anterior teeth and a prefabricated positioner. All methods gave equally positive clinical results in both the short-term, i.e. after one and two years of retention, and in the long-term, five years or more post-retention. After two years of retention, the level of compliance affected the retention treatment result. However, no such effect was shown for body height, the severity of initial crowding or gender. Today, there is increasing emphasis on the importance of economic aspects of healthcare. Of the three methods evaluated in this study, the least cost-effective, after two years of retention, was a vacuum-formed retainer combined with a bonded canine-to-canine retainer. The clinical implication of this finding is that in patients meeting the inclusion criteria, interproximal stripping of the mandibular anterior teeth, or the use of a prefabricated positioner, are highly appropriate alternatives to a mandibular bonded canine-to-canine retainer. The overall conclusions are that there are a number of effective retention methods available and the clinician is not limited to routine use of a bonded mandibular canine-to-canine retainer. The most appropriate retention method should be selected on an individual, case to case basis, taking into account such variables as orthodontic diagnosis, the expected level of patient compliance, patient preferences and financial considerations.
Long-term treatment effects of the FR-2 appliance: a prospective evalution 7 years post-treatment
Franchi, Lorenzo; Cevidanes, Lucia H. S.; Scanavini, Marco A.; McNamara, James A.
2014-01-01
AIM To examine the long-term effects induced by treatment with the function regulator (FR-2) appliance 7 years post-treatment compared with untreated class II subjects. SUBJECTS AND METHODS The FR-2 sample was collected prospectively and comprised 17 subjects (10 boys and 7 girls, mean age 10.8 years) who were treated with the FR-2 appliance for 1.7 years and re-evaluated 7.1 years after treatment. The step-by-step mandibular advancement was performed gradually (increments up to 3–4 mm), until a ‘super class I’ molar relationship was obtained. The control group consisted of 17 class II subjects (9 boys and 8 girls, mean age 11.3 years) with class II malocclusion, excessive overjet, and class II molar relationship, matched to the treated group as to ages at all times, gender distribution, and stages of skeletal maturity (evaluated by the cervical vertebral maturation method). The lateral cephalograms were analysed at T1 (initial), T2 (final), and T3 (7.1 years post-treatment). The compatibility between the groups and the comparisons of their changes at T1–T2, T2–T3, and T1–T3 intervals were examined by independent sample t-tests (P < 0.05). RESULTS FR-2 treatment provided a significant improvement in the maxillomandibular relationship due to an increase in mandibular length compared with controls, which remained stable over time. Also overjet, overbite, and molar relationship corrections demonstrated stability. Among dentoalveolar changes, only the increased mesial movement of the mandibular molars in the FR-2 group demonstrated stability. CONCLUSIONS Correction of class II malocclusion remained stable 7 years after FR-2 treatment mainly due to the stability of the skeletal changes. PMID:23736378
Surface passivation and aging of InGaAs/InP heterojunction phototransistors
NASA Astrophysics Data System (ADS)
Park, Min-Su; Razaei, Mohsen; Barnhart, Katie; Tan, Chee Leong; Mohseni, Hooman
2017-06-01
We report the effect of different surface treatment and passivation techniques on the stability of InGaAs/InP heterojunction phototransistors (HPTs). An In0.53Ga0.47As surface passivated with aqueous ammonium sulfide ((NH4)2S), aluminum oxide (Al2O3) grown by atomic layer deposition (ALD), and their combination is evaluated by using Raman spectroscopy and X-ray photoelectron spectroscopy (XPS). All samples were kept in the air ambient, and their performances were periodically measured to investigate their long-term stability. Raman spectroscopy revealed that the peak intensity of the GaAs-like longitudinal optical phonon of all passivated samples is decreased compared with that of the control sample. This is attributable to the diminution of the carriers near the passivated surfaces, which was proven by extracted surface potential (Vs). The Vs of all passivated samples was decreased to less than half of that for the control sample. XPS evaluation of As3d spectra showed that arsenic oxides (As2O3 and As2O5) on the surfaces of the samples can be removed by passivation. However, both Raman and XPS spectra show that the (NH4)2S passivated sample reverts back over time and will resemble the untreated control sample. When capped with ALD-grown Al2O3, passivated samples irrespective of the pretreatment show no degradation over the measured time of 4 weeks. Similar conclusions are made from our experimental measurement of the performance of differently passivated HPTs. The ALD-grown Al2O3 passivated devices show an improved optical gain at low optical powers and long-term stability.
NASA Astrophysics Data System (ADS)
Lue, Shingjiang Jessie; Lo, Pei Wen; Hung, Ling-Yung; Tung, Yung Liang
This research investigates the cell performance and long-term stability of dye-sensitized solar cells (DSSCs) containing micro-porous polycarbonate (PC) film as the frame work material to stabilize the electrolyte solution. The track-etched PC film has cylindrical pore geometry, which is beneficial for ion transport in the electrolyte trapped inside the PC film. The photovoltaic efficiency of the DSSC with 0.2-μm PC membrane is 5.75 ± 0.73% under irradiation of 100 mW cm -2, which is slightly lower than that (6.34 ± 0.44%) of cells without PC film. The differences in fill factor and open-circuit voltage between the DSSCs with and without PC film are not statistically significant. The long-term cell performance is carried out at continuous illumination of 100 mW cm -2 (1 sun) and in darkness at 60 °C for up to 1000 h. There is no significant efficiency difference between the cells with and without PC film in light soaking (4.33% vs. 4.52%) for 960 h. In darkness, however, the cells with PC film demonstrate much higher efficiency (at 2.37%) than cells without PC (0.85%) after 1000 h. The improved long-term efficiency data and the higher percentage of working cells confirm the superior lifetime and performance using the micro-porous PC film.
Wu, Liqian; Zhang, Lichun; Sun, Mingxia; Liu, Rui; Yu, Lingzhu; Lv, Yi
2017-12-19
Cataluminescence- (CTL-) based sensors are among the most attractive and effective tools for gas sensing, owing to their efficient selectivity, high sensitivity, and rapidity. As the sensing materials of CTL-based sensors, metal-based catalysts easily bring about high costs and environmental pollution of heavy metals. More importantly, the long-term stability of metal-based catalysts is usually rather poor. Metal-free catalysts have unique advantages such as environmental friendliness, low costs, and long-term stability, making them promising materials for CTL-based sensors. Herein, we report the fabrication of a CTL sensor based on a metal-free catalyst. F-doped cage-like SiC was synthesized by wet chemical etching. The as-prepared products showed a rapid, stable, highly selective, and sensitive cataluminescent response to H 2 S. The stability of the sensor was demonstrated to be fairly good for at least 15 days. After CTL tests, F-doped cage-like SiC retained its original morphology, structure, and chemical composition. In addition, to the best of our knowledge, this is the first report of a metal-free CTL sensor. Metal-free catalysts are environmentally friendly and low in cost and exhibit long-term stability, which could open a new avenue of CTL sensing.
Maki, S; Hirai, Y; Niino, T; Matsumoto, T
2015-01-01
Maintaining the genetic integrity in long-term tissue cultured and cryopreserved plants is important for the conservation of plant genetic resources. In this study, the genetic stability of cryopreserved wasabi shoot tips stored for 10 years at -150 degree C was visualized using Amplified Fragment Length Polymorphism (AFLP) and Methylation Sensitive Amplified Polymorphism (MSAP). The study included plants derived from cryopreserved shoot tips after 10.5 years storage at -150 degree C (LN10yr), after 2 h storage at -196 degree C (LN2hr), cryopreservation controls (No LN cooling (TC)) and non-treated controls without LN cooling (LC). The donor plants for LN2hr, TC and LC were also maintained in vitro at 20 degree C for the same period. Neither technique detected genetic variations in either control or cryopreserved plants. Some mutations were noted in plants maintained in tissue culture for 10 years. Comparison of genome stability for TC and LN2hr plants showed only a minor change in DNA. However, when comparing the LC and Ln10yr, many differences were found. We conclude that cryopreservation is a superior conservation method compared to tissue culture in maintaining genetic stability for a long-term storage of wasabi germplasm.
Effect of mesogenic ligands on short and long-term spectral stability of CdSe/ZnS quantum dots
NASA Astrophysics Data System (ADS)
Amaral, Jose; Betady, Edwin; Quint, Makiko; Martin, Denzal; Riahinasab, Sheida; Hirst, Linda; Ghosh, Sayantani
Surface modification of chemically synthesized CdSe/ZnS quantum dots (QDs) by performing a ligand-exchange can improve the optical properties, including short- and long-term photo-stability. Using a custom-designed mesogenic ligand, we significantly and advantageously alter the photophysical properties of CdSe/ZnS core-shell QDs. Our investigation is two-fold, as we follow the effect of ligand exchange on (1) the static and dynamic photoluminescence (PL) properties of QDs under continuous illumination, and (2) the temperature dependence of PL. We find that a reduction in Forster resonance energy transfer due to the ligand exchange process results in stabilizing both recombination lifetimes and emission intensity for over an hour of high power photo-excitation. Our temperature-dependent PL studies indicate thermally activated PL recovery at higher temperatures, and a lack of emission enhancement at low temperatures resulting from greater charge separation by the mesogenic ligands. We conclude that this process improves photoluminescence stability and sample longevity of QD films whose applications require long term resistance to photobleaching. This research was supported by funds from the National Aeronautics and Space Administration (NASA) Grant No. NNX15AQ01A, UCMEXUS-CONACYT, and National Science Foundation (NSF) Grants No. DMR-1056860, DMR-1359406 and CBET-1507551.
Keaveney, James; Hamlyn, William J; Adams, Charles S; Hughes, Ifan G
2016-09-01
We report on the development of a diode laser system - the "Faraday laser" - using an atomic Faraday filter as the frequency-selective element. In contrast to typical external-cavity diode laser systems which offer tunable output frequency but require additional control systems in order to achieve a stable output frequency, our system only lases at a single frequency, set by the peak transmission frequency of the internal atomic Faraday filter. Our system has both short-term and long-term stability of less than 1 MHz, which is less than the natural linewidth of alkali-atomic D-lines, making similar systems suitable for use as a "turn-key" solution for laser-cooling experiments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heep, Barbara K.; Weldert, Kai S.; Krysiak, Yasar
Superionic chalcopyrites have recently attracted interest in their use as potential thermoelectric materials because of extraordinary low thermal conductivities. To overcome long-term stability issues in thermoelectric generators using superionic materials at evaluated temperatures, materials need to be found that show good thermoelectric performance at moderate temperatures. Here, we present the structural and thermoelectric properties of the argyrodite Ag 8SiSe 6, which exhibits promising thermoelectric performance close to room temperature.
Satb2 determines miRNA expression and long-term memory in the adult central nervous system.
Jaitner, Clemens; Reddy, Chethan; Abentung, Andreas; Whittle, Nigel; Rieder, Dietmar; Delekate, Andrea; Korte, Martin; Jain, Gaurav; Fischer, Andre; Sananbenesi, Farahnaz; Cera, Isabella; Singewald, Nicolas; Dechant, Georg; Apostolova, Galina
2016-11-29
SATB2 is a risk locus for schizophrenia and encodes a DNA-binding protein that regulates higher-order chromatin configuration. In the adult brain Satb2 is almost exclusively expressed in pyramidal neurons of two brain regions important for memory formation, the cerebral cortex and the CA1-hippocampal field. Here we show that Satb2 is required for key hippocampal functions since deletion of Satb2 from the adult mouse forebrain prevents the stabilization of synaptic long-term potentiation and markedly impairs long-term fear and object discrimination memory. At the molecular level, we find that synaptic activity and BDNF up-regulate Satb2, which itself binds to the promoters of coding and non-coding genes. Satb2 controls the hippocampal levels of a large cohort of miRNAs, many of which are implicated in synaptic plasticity and memory formation. Together, our findings demonstrate that Satb2 is critically involved in long-term plasticity processes in the adult forebrain that underlie the consolidation and stabilization of context-linked memory.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-28
...; FEMA Form 078-0-2A, National Fire Academy (NFA) Long-Term Evaluation Student/Trainee; FEMA Form 078-0-2... Evaluation Student/Trainee; FEMA Form 078-0-2 (Presently FEMA Form 95-58), NFA Long-Term Evaluation...-term Evaluation Form for Supervisors and National Fire Academy Long-term Evaluation Form for Students...
Otten, Volker T C; Crnalic, Sead; Röhrl, Stephan M; Nivbrant, Bo; Nilsson, Kjell G
2016-01-01
Screws, pegs and hydroxyapatite-coating are used to enhance the primary stability of uncemented cups. We present a 14-year follow-up of 48 hips randomized to four groups: press-fit only, press-fit plus screws, press-fit plus pegs and hydroxyapatite-coated cups. Radiostereometric migration measurements showed equally good stability regardless cup augmentation. The mean wear rate was high, 0.21 mm/year, with no differences between the groups. Seven hips had radiographical osteolysis but only in hips with augmented cups. Cups without screw-holes compared with cups with screw-holes resulted in better clinical outcome at the 14-year follow-up. Thus, augmentation of uncemented cups with screws, pegs, or hydroxyapatite did not appear to improve the long-term stability compared with press-fit only. Copyright © 2016 Elsevier Inc. All rights reserved.
Stable radio-frequency transfer over optical fiber by phase-conjugate frequency mixing.
He, Yabai; Orr, Brian J; Baldwin, Kenneth G H; Wouters, Michael J; Luiten, Andre N; Aben, Guido; Warrington, R Bruce
2013-08-12
We demonstrate long-distance (≥100-km) synchronization of the phase of a radio-frequency reference over an optical-fiber network without needing to actively stabilize the optical path length. Frequency mixing is used to achieve passive phase-conjugate cancellation of fiber-length fluctuations, ensuring that the phase difference between the reference and synchronized oscillators is independent of the link length. The fractional radio-frequency-transfer stability through a 100-km "real-world" urban optical-fiber network is 6 × 10(-17) with an averaging time of 10(4) s. Our compensation technique is robust, providing long-term stability superior to that of a hydrogen maser. By combining our technique with the short-term stability provided by a remote, high-quality quartz oscillator, this system is potentially applicable to transcontinental optical-fiber time and frequency dissemination where the optical round-trip propagation time is significant.
A role of abdomen in butterfly's flapping flight
NASA Astrophysics Data System (ADS)
Jayakumar, Jeeva; Senda, Kei; Yokoyama, Naoto
2017-11-01
Butterfly's forward flight with periodic flapping motion is longitudinally unstable, and control of the thoracic pitching angle is essential to stabilize the flight. This study aims to comprehend roles which the abdominal motion play in the pitching stability of butterfly's flapping flight by using a two-dimensional model. The control of the thoracic pitching angle by the abdominal motion is an underactuated problem because of the limit on the abdominal angle. The control input of the thorax-abdomen joint torque is obtained by the hierarchical sliding mode control in this study. Numerical simulations reveal that the control by the abdominal motion provides short-term pitching stabilization in the butterfly's flight. Moreover, the control input due to a large thorax-abdomen joint torque can counteract a quite large perturbation, and can return the pitching attitude to the periodic trajectory with a short recovery time. These observations are consistent with biologists' view that living butterflies use their abdomens as rudders. On the other hand, the abdominal control mostly fails in long-term pitching stabilization, because it cannot directly alter the aerodynamic forces. The control for the long-term pitching stabilization will also be discussed.
Microstructural Changes in Inconel 740 After Long-Term Aging in the Presence and Absence of Stress
NASA Astrophysics Data System (ADS)
Unocic, K. A.; Shingledecker, J. P.; Tortorelli, P. F.
2014-12-01
The Ni-based alloy, Inconel® 740, is being extensively examined for use in advanced ultrasupercritical steam boilers because its precipitation-strengthened microstructure appears to offer the necessary creep strength under the high temperatures and pressures (up to 760°C and 35 MPa) needed for high efficiency power generation. However, because this application requires extremely long lifetimes under these conditions (up to 30 years), long-term microstructure stability is a major concern. In this paper, results from microstructural analyses of Inconel 740 specimens aged at 700 and 750°C in the presence and absence of creep loading for times up to ~31,000 h are presented. The primary focus was on the development of the eta η (Ni3Ti) phase and coarsening of coherent γ'-Ni3(Al,Ti) precipitates and its depletion near eta/matrix interfaces. However, despite these processes, Inconel 740 showed adequate long-term microstructural stability to assure adequate creep strength for the intended application.
Priebe, Stefan; Matanov, Aleksandra; Demi, Neli; Blagovcanin Simic, Joka; Jovanovic, Sandra; Gajic, Milena; Radonic, Elizabeta; Bajraktarov, Stojan; Boderscova, Larisa; Konatar, Monika; Nica, Raluca; Muijen, Matthijs
2012-06-01
Eight community mental health care centres (initiated by the South-Eastern Europe Stability Pact) in Albania, Bosnia-Herzegovina, Croatia, Macedonia, Moldova, Montenegro and Romania were evaluated. Characteristics of patients, patient reported outcomes and patient views of care were assessed in 305 psychiatric patients. Patient characteristics varied across centres, with most patients having long term psychotic disorders. Treatment satisfaction and therapeutic relationships were rated favourably. Subjective quality of life mean scores were rather low, with higher satisfaction with health and dissatisfaction with the financial and employment situation. Being unemployed was the only factor associated with poor quality of life and lower treatment satisfaction. Most developing centres target patients with persistent psychotic disorders. Care appears highly valued by the patients. The findings encourage establishing more centres in the region and call for employment schemes for people with mental illnesses.
NASA Astrophysics Data System (ADS)
Jia; Wang; Tian; Li; Xu; Jiao; Cao; Wu
2016-10-01
SiO2-based microcapsules containing hydrophobic molecules exhibited potential applications such as extrinsic self-healing, drug delivery, due to outstanding thermal and chemical stability of SiO2. However, to construct SiO2-based microcapsules with both high encapsulation loading and long-term structural stability is still a troublesome issue, limiting their further utilization. We herein design a single-batch route, a combined interfacial and in-situ polymerization strategy, to fabricate epoxy-containing SiO2-based microcapsules with both high encapsulation loading and long-term structural stability. The final SiO2-based microcapsules preserve high encapsulation loading of 85.7 wt% by controlling exclusively hydrolysis and condensed polymerization at oil/water interface in the initial interfacial polymerization step. In the subsequent in-situ polymerization step, the initial SiO2-based microcapsules as seeds could efficiently harvest SiO2 precursors and primary SiO2 particles to finely tune the SiO2 wall thickness, thereby enhancing long-term structural stability of the final SiO2-based microcapsules including high thermal stability with almost no any weight loss until 250°C, and strong tolerance against nonpolar solvents such as CCl4 with almost unchanged core-shell structure and unchanged core weight after immersing into strong solvents for up to 5 days. These SiO2-based microcapsules are extremely suited for processing them into anticorrosive coating in the presence of nonpolar solvents for self-healing application.
Fasciani, Chiara; Silvero, M Jazmin; Anghel, Maria Alexandra; Argüello, Gerardo A; Becerra, Maria Cecilia; Scaiano, Juan C
2014-12-17
Gold-silver core-shell nanoparticles stabilized with a common sweetener, aspartame (AuNP@Ag@Asm), combine the antimicrobial properties of silver with the photoinduced plasmon-mediated photothermal effects of gold. The particles were tested with several bacterial strains, while biocompatibility was verified with human dermal fibroblasts.
The lightest organic radical cation for charge storage in redox flow batteries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Jinhua; Pan, Baofei; Duan, Wentao
2016-08-25
Electrochemically reversible fluids of high energy density are promising materials for capturing the electrical energy generated from intermittent sources like solar and wind. To meet this technological challenge there is a need to understand the fundamental limits and interplay of electrochemical potential, stability and solubility in “lean” derivatives of redox-active molecules. Here we describe the process of molecular pruning, illustrated for 2,5-di-tert-butyl-1,4-bis(2-methoxyethoxy)benzene, a molecule known to produce a persistently stable, high-potential radical cation. By systematically shedding molecular fragments considered important for radical cation steric stabilization, we discovered a minimalistic structure that retains long-term stability in its oxidized form. Interestingly, wemore » find the tert-butyl groups are unnecessary; high stability of the radical cation and high solubility are both realized in derivatives having appropriately positioned arene methyl groups. These stability trends are rationalized by mechanistic considerations of the postulated decomposition pathways. We suggest that the molecular pruning approach will uncover lean redox active derivatives for electrochemical energy storage leading to materials with long-term stability and high intrinsic capacity.« less
The long-term hydrological effect of forest stands on the stability of slopes
NASA Astrophysics Data System (ADS)
Bogaard, T. A.; Meng, W.; van Beek, L. P. H.
2012-04-01
Forest is widely known to improve slope stability as a result of mechanical and hydrological effects. While the mechanics underlying the stabilizing process of root reinforcement are well understood and quantified, the influence of forest on the occurrence of critical hydrological conditions in terms of suction or pore pressure remains uncertain. Due to seasonal and inter-annual fluctuations, the stabilizing influence of evaporation and transpiration is difficult to isolate from the overall noise of the hydrological signal. More long-term effects of forest stands on soil development are highly variable and thus difficult to observe and quantify. Often these effects are ambivalent, having potentially a stabilizing or destabilizing influence on a slope under particular conditions (e.g., more structured soils leading to both rapid infiltration and drainage). Consequently, it can be postulated that forests will hydrologically influence the magnitude-frequency distribution of landsliding, not only at the stand level but also on a regional scale through the groundwater system. The overall aim of this research is to understand and quantify the stabilizing hydrological effect of forests on potentially unstable slopes. To this end, we focus on the changes in the magnitude-frequency distribution of landsliding that arise as a result of variations in evapotranspiration losses over the life cycle of stands. Temporal variations in evapotranspiration comprise first of all the interception that can account for an important amount of evaporation from a forest, and that changes with seasonal and annual variations in the interception capacity of the canopy and forest floor. Transpiration also represents an important loss that varies over the various growth stages of a forest stand. Based on a literature review of water consumption by tree species and water balance studies of forested catchments we defined the potential transpiration for different growth stages. This information we used in a spatially distributed, physical-based, dynamical model to simulate the hydrology and resulting stability for a catchment on a daily scale. The results can be used to identify end members of the hydrological influence of forests on slope stability and the typical variations in stability associated with the various growth stages. They indicate that the influence of forest stand age on the water consumption can be significant and has clear consequences for the antecedent soil moisture condition within a slope and thus on the potential for slope destabilization. The outcome should help to understand the long-term impact of vegetation on slope hydrology and define sustainable and reliable management strategies at the scale of forest stands. Keywords: slope stability, hydrology, vegetation, long-tem effect
SiC/Mg multilayer coatings for SCORE coronagraph: long term stability analysis
NASA Astrophysics Data System (ADS)
Pelizzo, Maria Guglielmina; Fineschi, Silvano; Zuppella, Paola; Corso, Alain Jody; Windt, David L.; Nicolosi, Piergiorgio
2011-10-01
SiC/Mg multilayers have been used as coatings of the Sounding-rocket CORonagraphic Experiment (SCORE) telescope mirrors launched during the NASA HERSCHEL program. This materials couple has been largely studied by researchers since it provides higher performances than a standard Mo/Si multilayer; the SCORE mirrors show in fact a peak reflectance of around 40% at HeII 30.4 nm. Nevertheless, long term stability of this coating is an open problem. A study on the aging and stability of this multilayer has been carried on. SiC/Mg multilayer samples characterized by different structural parameters have been deposited. They have been measured just after deposition and four years later to verify degradation based on natural aging. Experimental results and analysis are presented.
Burtis, James C; Sullivan, Patrick; Levi, Taal; Oggenfuss, Kelly; Fahey, Timothy J; Ostfeld, Richard S
2016-11-25
The incidence of Lyme disease shows high degrees of inter-annual variation in the northeastern United States, but the factors driving this variation are not well understood. Complicating matters, it is also possible that these driving factors may vary in regions with differing histories of Lyme disease endemism. We evaluated the effect of the number of hot (T > 25 °C), dry (precipitation = 0) days during the questing periods of the two immature Ixodes scapularis life stages (larval and nymphal) on inter-annual variation in Lyme disease incidence between 2000 and 2011 in long-term endemic versus recently endemic areas. We also evaluated the effect of summer weather on tick questing activity and the number of ticks found on small mammals between 1994 and 2012 on six sites in Millbrook, NY. The number of hot, dry days during the larval period of the previous year did not affect the human incidence of Lyme disease or the density of questing nymphs the following season. However, dry summer weather during the nymphal questing period had a significant negative effect on the incidence of Lyme disease in the long-term endemic areas, and on the density of questing nymphs. Summer weather conditions had a more pronounced effect on actively questing I. scapularis collected via dragging than on the number of ticks found feeding on small mammals. In recently endemic areas Lyme disease incidence increased significantly over time, but no trend was detected between disease incidence and dry summer weather. Recently endemic regions showed an increase in Lyme disease incidence over time, while incidence in long-term endemic regions appears to have stabilized. Only within the stabilized areas were we able to detect reduced Lyme disease incidence in years with hot, dry summer weather. These patterns were reflected in our field data, which showed that questing activity of nymphal I. scapularis was reduced by hot, dry summer weather.
Osseous genioplasty: A case series
Deshpande, Sanjeev N.; Munoli, Amarnath V.
2011-01-01
Introduction: The chin (mentum) is vital to the human facial morphology as it contributes to the facial aesthetics and harmony both on frontal and lateral views. Osseous genioplasty, the alteration of the chin through skeletal modification, can lead to significant enhancement of the overall facial profile. Aim and Study Design: A case series was designed to study the long-term results of osseous genioplasty in Indian patients with regard to patient satisfaction, complications, and long-term stability. Materials and Methods: All subjects who underwent osseous genioplasty either alone or as a component of orthognathic surgery between January 1992 and December 2010, with a minimum follow-up of 2 years, were included. The genioplasty was performed using standard protocols of assessment and execution. Post-operative evaluation included patient satisfaction, complications and radiological evidence of long-term stability. A comprehensive score was formulated for the purpose of the study. Results: Thirty-seven subjects underwent osseous genioplasty with at least 2 years of follow-up in the study period. This included 17 male and 20 female subjects, with a mean age of 22.8 years (15-52 years) and a mean follow-up of 3 years 4 months (2 years to 4 years and 11 months). Nineteen subjects underwent isolated genioplasty while 18 underwent genioplasty as a part of orthognathic surgery. The procedures included advancement (22), pushback (9), side-to-side (4) and vertical reduction (2) genioplasty. Thirty-six subjects (97.3%) were extremely pleased with the results with only one subject expressing reservations, without, however, demanding any further procedure. There were no significant complications. The osteotomised segment was well maintained in its new position with good bony union and minimal resorption. Overall, 35 (94.6%) cases had excellent results and 2 (4.4%) cases had good results, according to the comprehensive score. Conclusions: Osseous genioplasty is a safe and effective means of creating a beautiful and balanced facial profile by producing alterations in the chin morphology with minimal complications and excellent and stable long-term results. PMID:22279273
Basic performance and stability of a CdTe solid-state detector panel.
Tsuchiya, Katsutoshi; Takahashi, Isao; Kawaguchi, Tsuneaki; Yokoi, Kazuma; Morimoto, Yuuichi; Ishitsu, Takafumi; Suzuki, Atsurou; Ueno, Yuuichirou; Kobashi, Keiji
2010-05-01
We have developed a prototype gamma camera system (R1-M) using a cadmium telluride (CdTe) detector panel and evaluated the basic performance and the spectral stability. The CdTe panel consists of 5-mm-thick crystals. The field of view is 134 x 268 mm comprising 18,432 pixels with a pixel pitch of 1.4 mm. Replaceable small CdTe modules are mounted on to the circuit board by dedicated zero insertion force connectors. To make the readout circuit compact, the matrix read out is processed by dedicated ASICs. The panel is equipped with a cold-air cooling system. The temperature and humidity in the panel were kept at 20 degrees C and below 70% relative humidity. CdTe polarization was suppressed by the bias refresh technique to stabilize the detector. We also produced three dedicated square pixel-matched collimators: LEGP (20 mm-thick), LEHR (27 mm-thick), and LEUHR (35 mm-thick). We evaluated their basic performance (energy resolution, system resolution, and sensitivity) and the spectral stability in terms of short-term (several hours of continuous acquisition) and long-term (infrequent measurements over more than a year) activity. The intrinsic energy resolution (FWHM) acquired with Tc-99m (140.5 keV) was 6.6%. The spatial resolutions (FWHM at a distance of 100 mm) with LEGP, LEHR, and LEUHR collimators were 5.7, 4.9, and 4.2 mm, and the sensitivities were 71, 39, and 23 cps/MBq, respectively. The energy peak position and the intrinsic energy resolution after several hours of operation were nearly the same as the values a few minutes after the system was powered on; the variation of the peak position was <0.2%, and that of the resolution was about 0.3%. Infrequent measurements conducted over a year showed that the variations of the energy peak position and the intrinsic energy resolution of the system were at a similar level to those described above. The basic performance of the CdTe-gamma camera system was evaluated, and its stability was verified. It was shown that the camera could be operated daily for several months without calibration.
Feng, Jie; Zhang, Yingyue; McManus, Simon A; Ristroph, Kurt D; Lu, Hoang D; Gong, Kai; White, Claire E; Prud'homme, Robert K
2018-05-25
While the formulation of nanoparticle (NP) suspensions has been widely applied in materials and life science, the recovery of NPs from such a suspension into a solid state is practically important to confer long-term storage stability. However, solidification, while preserving the original nanoscale properties, remains a formidable challenge in the pharmaceutical and biomedical applications of NPs. Herein we combined flash nanoprecipitation (FNP) and spray-drying as a nanofabrication platform for NP formulation and recovery without compromising the dissolution kinetics of the active ingredient. Clofazimine was chosen to be the representative drug, which has been recently repurposed as a potential treatment for cryptosporidiosis. Clofazimine was encapsulated in NPs with low-cost surface coatings, hypromellose acetate succinate (HPMCAS) and lecithin, which were required by the ultimate application to global health. Spray-drying and lyophilization were utilized to produce dried powders with good long-term storage stability for application in hot and humid climatic zones. The particle morphology, yield efficiency, drug loading, and clofazimine crystallinity in the spray-dried powders were characterized. The in vitro release kinetics of spray-dried NP powders were compared to analogous dissolution profiles from standard lyophilized NP samples, crystalline clofazimine powder, and the commercially available formulation Lamprene. The spray-dried powders showed a supersaturation level of up to 60 times the equilibrium solubility and remarkably improved dissolution rates. In addition, the spray-dried powders with both surface coatings showed excellent stability during aging studies with elevated temperature and humidity, in view of the dissolution and release in vitro. Considering oral delivery for pediatric administration, the spray-dried powders show less staining effects with simulated skin than crystalline clofazimine and may be made into minitablets without additional excipients. These results highlight the potential of combining FNP and spray-drying as a feasible and versatile platform to design and rapidly recover amorphous NPs in a solid dosage form, with the advantages of satisfactory long-term storage stability, low cost, and easy scalability.
Long-term consolidation of declarative memory: insight from temporal lobe epilepsy.
Tramoni, Eve; Felician, Olivier; Barbeau, Emmanuel J; Guedj, Eric; Guye, Maxime; Bartolomei, Fabrice; Ceccaldi, Mathieu
2011-03-01
Several experiments carried out with a subset of patients with temporal lobe epilepsy have demonstrated normal memory performance at standard delays of recall (i.e. minutes to hours) but impaired performance over longer delays (i.e. days or weeks), suggesting altered long-term consolidation mechanisms. These mechanisms were specifically investigated in a group of five adult-onset pharmaco-sensitive patients with temporal lobe epilepsy, exhibiting severe episodic memory complaints despite normal performance at standardized memory assessment. In a first experiment, the magnitude of autobiographical memory loss was evaluated using retrograde personal memory tasks based on verbal and visual cues. In both conditions, results showed an unusual U-shaped pattern of personal memory impairment, encompassing most of the patients' life, sparing however, periods of the childhood, early adulthood and past several weeks. This profile was suggestive of a long-term consolidation impairment of personal episodes, adequately consolidated over 'short-term' delays but gradually forgotten thereafter. Therefore, in a subsequent experiment, patients were submitted to a protocol specifically devised to investigate short and long-term consolidation of contextually-bound experiences (episodic memory) and context-free information (semantic knowledge and single-items). In the short term (1 h), performance at both contextually-free and contextually-bound memory tasks was intact. After a 6-week delay, however, contextually-bound memory performance was impaired while contextually-free memory performance remained preserved. This effect was independent of task difficulty and the modality of retrieval (recall and recognition). Neuroimaging studies revealed the presence of mild metabolic changes within medial temporal lobe structures. Taken together, these results show the existence of different consolidation systems within declarative memory. They suggest that mild medial temporal lobe dysfunction can impede the building and stabilization of episodic memories but leaves long-term semantic and single-items mnemonic traces intact.
USDA-ARS?s Scientific Manuscript database
Fundamental processing needs identified by industry for the large-scale manufacture of biofuels and bioproducts from sweet sorghum (Sorghum bicolor L. Moench), include the long-term storage of 65 Brix syrups for year-round supply, efficient transport, and acceptable end-product yields. Sweet sorghu...
USDA-ARS?s Scientific Manuscript database
No tillage (NT) and N fertilization can increase surface soil organic C (SOC) stocks, but the effects deeper in the soil profile are uncertain. Subsequent tillage could counter SOC stabilized through NT practices by disrupting soil aggregation and promoting decomposition. We followed a long-term ti...
Schermeyer, Marie-Therese; Wöll, Anna K.; Eppink, Michel; Hubbuch, Jürgen
2017-01-01
ABSTRACT High protein titers are gaining importance in biopharmaceutical industry. A major challenge in the development of highly concentrated mAb solutions is their long-term stability and often incalculable viscosity. The complexity of the molecule itself, as well as the various molecular interactions, make it difficult to describe their solution behavior. To study the formulation stability, long- and short-range interactions and the formation of complex network structures have to be taken into account. For a better understanding of highly concentrated solutions, we combined established and novel analytical tools to characterize the effect of solution properties on the stability of highly concentrated mAb formulations. In this study, monoclonal antibody solutions in a concentration range of 50–200 mg/ml at pH 5–9 with and without glycine, PEG4000, and Na2SO4 were analyzed. To determine the monomer content, analytical size-exclusion chromatography runs were performed. ζ-potential measurements were conducted to analyze the electrophoretic properties in different solutions. The melting and aggregation temperatures were determined with the help of fluorescence and static light scattering measurements. Additionally, rheological measurements were conducted to study the solution viscosity and viscoelastic behavior of the mAb solutions. The so-determined analytical parameters were scored and merged in an analytical toolbox. The resulting scoring was then successfully correlated with long-term storage (40 d of incubation) experiments. Our results indicate that the sensitivity of complex rheological measurements, in combination with the applied techniques, allows reliable statements to be made with respect to the effect of solution properties, such as protein concentration, ionic strength, and pH shift, on the strength of protein-protein interaction and solution colloidal stability. PMID:28617076
Kichou, Sofiane; Silvestre, Santiago; Nofuentes, Gustavo; Torres-Ramírez, Miguel; Chouder, Aissa; Guasch, Daniel
2016-01-01
Four years׳ behavioral data of thin-film single junction amorphous silicon (a-Si) photovoltaic (PV) modules installed in a relatively dry and sunny inland site with a Continental-Mediterranean climate (in the city of Jaén, Spain) are presented in this article. The shared data contributes to clarify how the Light Induced Degradation (LID) impacts the output power generated by the PV array, especially in the first days of exposure under outdoor conditions. Furthermore, a valuable methodology is provided in this data article permitting the assessment of the degradation rate and the stabilization period of the PV modules. Further discussions and interpretations concerning the data shared in this article can be found in the research paper “Characterization of degradation and evaluation of model parameters of amorphous silicon photovoltaic modules under outdoor long term exposure” (Kichou et al., 2016) [1]. PMID:26977439
A comparison of biophysical characterization techniques in predicting monoclonal antibody stability.
Thiagarajan, Geetha; Semple, Andrew; James, Jose K; Cheung, Jason K; Shameem, Mohammed
2016-01-01
With the rapid growth of biopharmaceutical product development, knowledge of therapeutic protein stability has become increasingly important. We evaluated assays that measure solution-mediated interactions and key molecular characteristics of 9 formulated monoclonal antibody (mAb) therapeutics, to predict their stability behavior. Colloidal interactions, self-association propensity and conformational stability were measured using effective surface charge via zeta potential, diffusion interaction parameter (kD) and differential scanning calorimetry (DSC), respectively. The molecular features of all 9 mAbs were compared to their stability at accelerated (25°C and 40°C) and long-term storage conditions (2-8°C) as measured by size exclusion chromatography. At accelerated storage conditions, the majority of the mAbs in this study degraded via fragmentation rather than aggregation. Our results show that colloidal stability, self-association propensity and conformational characteristics (exposed tryptophan) provide reasonable prediction of accelerated stability, with limited predictive value at 2-8°C stability. While no correlations to stability behavior were observed with onset-of-melting temperatures or domain unfolding temperatures, by DSC, melting of the Fab domain with the CH2 domain suggests lower stability at stressed conditions. The relevance of identifying appropriate biophysical assays based on the primary degradation pathways is discussed.
Long time stability of lamps with nanostructural carbon field emission cathodes
NASA Astrophysics Data System (ADS)
Kalenik, J.; Firek, P.; Szmidt, J.; Czerwosz, E.; Kozłowski, M.; Stepińska, I.; Wódka, T.
2017-08-01
A luminescent lamp with field emission cathode was constructed and tested. Phosphor excited by electrons from field emission cathode is the source of light. The cathode is covered with nickel-carbon film containing multilayer carbon nanotubes that enhance electron emission from the cathode. Results of luminance stability measurements are presented. Luminance of elaborated luminance lamp is high enough for lighting application. Long term stability (1000 hours) is satisfactory for mass lamp application. Initial short time decrease of luminance is still too high and it needs reduction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pierce, Eric M.; Mattigod, Shas V.; Westsik, Joseph H.
2010-01-30
Pacific Northwest National Laboratory has initiated a waste form testing program to support the long-term durability evaluation of a waste form for secondary wastes generated from the treatment and immobilization of Hanford radioactive tank wastes. The purpose of the work discussed in this report is to identify candidate stabilization technologies and getters that have the potential to successfully treat the secondary waste stream liquid effluent, mainly from off-gas scrubbers and spent solids, produced by the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Down-selection to the most promising stabilization processes/waste forms is needed to support the design of a solidificationmore » treatment unit (STU) to be added to the Effluent Treatment Facility (ETF). To support key decision processes, an initial screening of the secondary liquid waste forms must be completed by February 2010.« less
Stabilization of Neem Oil Biodiesel with Corn Silk Extract during Long-term Storage.
Ali, Rehab Farouk M; El-Anany, Ayman M
2017-02-01
The current study aimed to evaluate the antioxidant efficiency of different extracts of corn silk. In addition, the impact of corn silk extract on oxidative stability of neem biodiesel during storage was studied. The highest phenolics, DPPH radical scavenging and reducing power activities were recorded for methanol-water extract. The longest oxidation stability (10 h) was observed for biodiesel samples blended with 1000 ppm of corn silk extract (CSE). At the end of storage period the induction time of biodiesel samples mixed with 1000 ppm of CSE or butylated hydroxytoluene (BHT) were about 6.72 and 5.63 times as high as in biodiesel samples without antioxidants. Biodiesel samples blended with 1000 ppm of CSE had the lowest acidity at the end of storage period. Peroxide value of biodiesel samples containing 1000 ppm of CSE was about 4.28 times as low as in control sample without antioxidants.
NASA Astrophysics Data System (ADS)
Polyakov, V. V.
During a final 4-month stage of I-year space flight of cosmonauts Titov and Manarov, a physician, Valery Polyakov was included on a crew for the purpose of evaluating their health, correcting physical status to prepare for the spacecraft reentry and landing operations. The complex program of scientific investigations and experiments performed by a physician included an evaluation of adaptation reactions of the human body at different stages of space mission using clinicophysiological and biochemical methods; testing of alternative regimes of exercises and new countermeasures to prevent an unfavorable effect of long-term weightlessness.
Furlong, E.T.; Martin, Jeffrey D.; Werner, S.L.; Gates, Paul M.
2002-01-01
The sensitivity and selective determination of polar pesticides were analyzed using high-performance liquid chromatography/electrospray ionization-mass spectrometry (HPLC/ESI-MS). The effects of multiple operators and instruments on method performance were evaluated using 440 pairs of fortified reagent-water and blank reagent-water samples. The influence of varying environmental matrices on recovery and precision were also analyzed using 200 fortified ambient water samples and duplicate ambient water samples. The results show that compound stability in filtered water was matrix-, chemical class- and compound-dependent which ranged from 1 day to 2 weeks.
Assessment of Nutrient Stability in Space Foods
NASA Technical Reports Server (NTRS)
Zwart, S. R.; Perchonok, M.; Braby, L. A.; Kloeris, V. A.; Smith, S. M.
2009-01-01
Maintaining an intact nutrient supply in the food system flown on spacecraft is a critical issue for mission success and crew health and safety. Early polar expeditions and exploration expeditions by sailing vessels have taught us that a deficiency, or excess, of even a single vitamin in the food supply can be catastrophic. Evidence from ground-based research indicates that some vitamins are destroyed and fatty acids are oxidized (and therefore rendered dangerous or useless) by different types of radiation and by conditions of long-term storage. We hypothesize that radiation and long-term storage in the space-flight environment will affect the stability of vitamins, amino acids, and fatty acids in the space food system. The research objectives of our ongoing stability studies are to determine the stability of water- and fat-soluble vitamins, fatty acids, and amino acids in the space food supply before and after space flight on the International Space Station (ISS). Foods were analyzed after 2 weeks (a flight control), 11, 19, and 28 months of flight. Along with the space-flown foods, ground-based controls matched for time, light, and temperature are analyzed. The flight studies complement planned ground-based studies of the effects of radiation on vitamins, amino acids, and fatty acids. Flight studies are needed because a model based on ground-based data cannot predict all of the effects of the space-flight environment. Flight studies provide a more accurate test system to determine the effects on these nutrients of the temperature, and radiation conditions in the space-flight environment. Ground studies are required to evaluate longer missions and higher radiation levels expected outside low-Earth orbit. In addition to providing information about nutrient stability in space, the results of these studies will help NASA determine if a need exists to develop special packaging that can ensure stability of foods and nutrients in space, or if further studies of nutrient metabolism or nutrient requirements are needed.
Marzouk, Eiman S; Kassem, Hassan E
2016-07-01
This study evaluated the long-term stability of maxillary molar intrusion and anterior open-bite correction in adults treated by maxillary posterior teeth intrusion with zygomatic miniplates. The sample included 26 skeletal anterior open-bite patients, who had maxillary posterior segment intrusion with zygomatic miniplates. Lateral cephalograms were taken at pretreatment, posttreatment, 1 year posttreatment, and 4 years posttreatment. The mean maxillary molar intrusion was 3.04 mm (P ≤0.01), and the mean bite closure was 6.93 mm (P ≤0.01). The intruded maxillary molars relapsed by 10.20% in the first year after treatment and by 13.37% by 4 years after treatment. Overbite relapsed by 8.19% and 11.18% after 1 year and 4 years posttreatment, respectively. The first year after treatment accounted for 76.29% and 73.2% of the total relapses of molar intrusion and overbite, respectively. The 4-year posttreatment relapse amounts of maxillary molar intrusion and overbite were positively correlated with the amount of pretreatment maxillary molar height and the initial open-bite severity, respectively, but negatively correlated with the amounts of maxillary molar intrusion and open-bite correction gained by treatment. Molar intrusion with zygomatic miniplates appears to be stable 4 years after treatment. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Current and Future Perspectives on Alginate Encapsulated Pancreatic Islet.
Strand, Berit L; Coron, Abba E; Skjak-Braek, Gudmund
2017-04-01
Transplantation of pancreatic islets in immune protective capsules holds the promise as a functional cure for type 1 diabetes, also about 40 years after the first proof of principal study. The concept is simple in using semipermeable capsules that allow the ingress of oxygen and nutrients, but limit the access of the immune system. Encapsulated human islets have been evaluated in four small clinical trials where the procedure has been evaluated as safe, but lacking long-term efficacy. Host reactions toward the biomaterials used in the capsules may be one parameter limiting the long-term function of the graft in humans. The present article briefly discusses important capsule properties such as stability, permeability and biocompatibility, as well as possible strategies to overcome current challenges. Also, recent progress in capsule development as well as the production of insulin-producing cells from human stem cells that gives promising perspectives for the transplantation of encapsulated insulin-producing tissue is briefly discussed. Stem Cells Translational Medicine 2017;6:1053-1058. © 2017 The Authors Stem Cells Translational Medicine published by Wiley Periodicals, Inc. on behalf of AlphaMed Press.
Zairian Political Conditions and Prospects for Economic Development,
1984-08-15
political conditions and potential for long-term economic development. Two different approaches to the question of political stability and economic...development are presented. Each assumes that political stability is a necessary, though not sufficient, condition for economic development and that, therefore
Monitoring and modeling of long-term settlements of an experimental landfill in Brazil.
Simões, Gustavo Ferreira; Catapreta, Cícero Antônio Antunes
2013-02-01
Settlement evaluation in sanitary landfills is a complex process, due to the waste heterogeneity, time-varying properties and influencing factors and mechanisms, such as mechanical compression due to load application and creep, and physical-chemical and biological processes caused by the wastes decomposition. Many empirical models for the analysis of long-term settlement in landfills are reported in the literature. This paper presents the results of a settlement monitoring program carried out during 6 years in Belo Horizonte experimental landfill. Different sets of field data were used to calibrate three long-term settlement prediction models (rheological, hyperbolic and composite). The parameters obtained in the calibration were used to predict the settlements and to compare with actual field data. During the monitoring period of 6 years, significant vertical strains were observed (of up to 31%) in relation to the initial height of the experimental landfill. The results for the long-term settlement prediction obtained by the hyperbolic and rheological models significantly underestimate the settlements, regardless the period of data used in the calibration. The best fits were obtained with the composite model, except when 1 year field data were used in the calibration. The results of the composite model indicate settlements stabilization at larger times and with larger final settlements when compared to the hyperbolic and rheological models. Copyright © 2012 Elsevier Ltd. All rights reserved.
Assessment of Dry Epidermal Electrodes for Long-Term Electromyography Measurements
Peters, Keshia M.; Milovanovic, Ivana; Kuang, Irene; Yang, Zeyu; Lu, Nanshu; Steele, Katherine M.
2018-01-01
Commercially available electrodes can only provide quality surface electromyography (sEMG) measurements for a limited duration due to user discomfort and signal degradation, but in many applications, collecting sEMG data for a full day or longer is desirable to enhance clinical care. Few studies for long-term sEMG have assessed signal quality of electrodes using clinically relevant tests. The goal of this research was to evaluate flexible, gold-based epidermal sensor system (ESS) electrodes for long-term sEMG recordings. We collected sEMG and impedance data from eight subjects from ESS and standard clinical electrodes on upper extremity muscles during maximum voluntary isometric contraction tests, dynamic range of motion tests, the Jebsen Taylor Hand Function Test, and the Box & Block Test. Four additional subjects were recruited to test the stability of ESS signals over four days. Signals from the ESS and traditional electrodes were strongly correlated across tasks. Measures of signal quality, such as signal-to-noise ratio and signal-to-motion ratio, were also similar for both electrodes. Over the four-day trial, no significant decrease in signal quality was observed in the ESS electrodes, suggesting that thin, flexible electrodes may provide a robust tool that does not inhibit movement or irritate the skin for long-term measurements of muscle activity in rehabilitation and other applications. PMID:29677129
24 CFR 578.37 - Program components and uses of assistance.
Code of Federal Regulations, 2013 CFR
2013-04-01
...-term (up to 3 months) and/or medium-term (for 3 to 24 months) tenant-based rental assistance, as set... providing short-term and/or medium-term rental assistance to program participants, the rental assistance is... ensuring long-term housing stability. The project is exempt from this requirement if the Violence Against...
24 CFR 578.37 - Program components and uses of assistance.
Code of Federal Regulations, 2014 CFR
2014-04-01
...-term (up to 3 months) and/or medium-term (for 3 to 24 months) tenant-based rental assistance, as set... providing short-term and/or medium-term rental assistance to program participants, the rental assistance is... ensuring long-term housing stability. The project is exempt from this requirement if the Violence Against...
Figueiredo, Carolina Calsolari; de Andrade, Adriana Neves; Marangoni-Castan, Andréa Tortosa; Gil, Daniela; Suriano, Italo Capraro
2015-01-01
ABSTRACT Objective To investigate the long-term efficacy of acoustically controlled auditory training in adults after tarumatic brain injury. Methods A total of six audioogically normal individuals aged between 20 and 37 years were studied. They suffered severe traumatic brain injury with diffuse axional lesion and underwent an acoustically controlled auditory training program approximately one year before. The results obtained in the behavioral and electrophysiological evaluation of auditory processing immediately after acoustically controlled auditory training were compared to reassessment findings, one year later. Results Quantitative analysis of auditory brainsteim response showed increased absolute latency of all waves and interpeak intervals, bilaterraly, when comparing both evaluations. Moreover, increased amplitude of all waves, and the wave V amplitude was statistically significant for the right ear, and wave III for the left ear. As to P3, decreased latency and increased amplitude were found for both ears in reassessment. The previous and current behavioral assessment showed similar results, except for the staggered spondaic words in the left ear and the amount of errors on the dichotic consonant-vowel test. Conclusion The acoustically controlled auditory training was effective in the long run, since better latency and amplitude results were observed in the electrophysiological evaluation, in addition to stability of behavioral measures after one-year training. PMID:26676270
Xu, Xiaomeng; Brown, Lucy; Aron, Arthur; Cao, Guikang; Feng, Tingyong; Acevedo, Bianca; Weng, Xuchu
2012-09-20
Early-stage romantic love is associated with activation in reward and motivation systems of the brain. Can these localized activations, or others, predict long-term relationship stability? We contacted participants from a previous fMRI study of early-stage love by Xu et al. [34] after 40 months from initial assessments. We compared brain activation during the initial assessment at early-stage love for those who were still together at 40 months and those who were apart, and surveyed those still together about their relationship happiness and commitment at 40 months. Six participants who were still with their partners at 40 months (compared to six who had broken up) showed less activation during early-stage love in the medial orbitofrontal cortex, right subcallosal cingulate and right accumbens, regions implicated in long-term love and relationship satisfaction [1,2]. These regions of deactivation at the early stage of love were also negatively correlated with relationship happiness scores collected at 40 months. Other areas involved were the caudate tail, and temporal and parietal lobes. These data are preliminary evidence that neural responses in the early stages of romantic love can predict relationship stability and quality up to 40 months later in the relationship. The brain regions involved suggest that forebrain reward functions may be predictive for relationship stability, as well as regions involved in social evaluation, emotional regulation, and mood. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Wang, Yi; Li, Chunyue; Tu, Cong; Hoyt, Greg D; DeForest, Jared L; Hu, Shuijin
2017-12-31
Intensive tillage and high inputs of chemicals are frequently used in conventional agriculture management, which critically depresses soil properties and causes soil erosion and nonpoint source pollution. Conservation practices, such as no-tillage and organic farming, have potential to enhance soil health. However, the long-term impact of no-tillage and organic practices on soil microbial diversity and community structure has not been fully understood, particularly in humid, warm climate regions such as the southeast USA. We hypothesized that organic inputs will lead to greater microbial diversity and a more stable microbial community, and that the combination of no-tillage and organic inputs will maximize soil microbial diversity. We conducted a long-term experiment in the southern Appalachian mountains of North Carolina, USA to test these hypotheses. The results showed that soil microbial diversity and community structure diverged under different management regimes after long term continuous treatments. Organic input dominated the effect of management practices on soil microbial properties, although no-tillage practice also exerted significant impacts. Both no-tillage and organic inputs significantly promoted soil microbial diversity and community stability. The combination of no-tillage and organic management increased soil microbial diversity over the conventional tillage and led to a microbial community structure more similar to the one in an adjacent grassland. These results indicate that effective management through reducing tillage and increasing organic C inputs can enhance soil microbial diversity and community stability. Copyright © 2017 Elsevier B.V. All rights reserved.
Is Cu a stable electrode material in hybrid perovskite solar cells for a 30-year lifetime?
Zhao, Jingjing; Zheng, Xiaopeng; Deng, Yehao; ...
2016-10-28
One grand challenge for long-lived perovskite solar cells is that the common electrode materials in solar cells, such as silver and aluminum or even gold, strongly react with hybrid perovskites. Here we report the evaluation of the potential of copper (Cu) as the electrode material in perovskite solar cells for long-term stability. In encapsulated devices which limit exposure to oxygen and moisture, Cu in direct contact with CH 3NH 3PbI 3 showed no reaction at laboratory time scales, and is predicted to be stable for almost 170 years at room temperature and over 22 years at the nominal operating cellmore » temperature of 40 °C. No diffusion of Cu into CH 3NH 3PbI 3 has been observed after thermal annealing for over 100 hours at 80 °C, nor does Cu cause charge trap states in direct contact with CH 3NH 3PbI 3 after long-term thermal annealing or illumination. High performance devices with efficiency above 20% with Cu electrode retains 98% of the initial efficiency after 816 hours storage in ambient environment without encapsulation. Finally, the results indicate Cu is a promising low-cost electrode material for perovskite solar cells for long-term operation.« less
Pelvic ring injuries: Surgical management and long-term outcomes
Halawi, Mohamad J.
2016-01-01
Pelvic ring injuries present a therapeutic challenge to the orthopedic surgeon. Management is based on the patient's physiological status, fracture classification, and associated injuries. Surgical stabilization is indicated in unstable injury patterns and those that fail nonsurgical management. The optimal timing for definitive fixation is not clearly defined, but early stabilization is recommended. Surgical techniques include external fixation, open reduction and internal fixation, and minimally invasive percutaneous osteosynthesis. Special considerations are required for concomitant acetabular fractures, sacral fractures, and those occurring in skeletally immature patients. Long-term outcomes are limited by lack of pelvis-specific outcome measures and burden of associated injuries. PMID:26908968
Effects of graphite fiber stability on the properties of PMR polyimide composites
NASA Technical Reports Server (NTRS)
Delvigs, P.; Alston, W. B.; Vannucci, R. D.
1979-01-01
The effect of the stability of graphite fibers on composite properties after exposure in air at 600 F was investigated. Composites were fabricated from PMR-15 and PMR-2 monomer solutions, using HTS-2 and Celion 6000 graphite fibers as the reinforcement. The effect of long-term exposure in air at 600 F on composite weight loss and mechanical properties was determined. These composites exhibited a significantly increased lifetime at that temperature compared to composites fabricated from HTS fiber sold prior to 1975. The effect of the PMR-15 and PMR-II resin compositions on long-term composite performance at 600 F is also discussed.
Kwon, Jimin; Takeda, Yasunori; Fukuda, Kenjiro; Cho, Kilwon; Tokito, Shizuo; Jung, Sungjune
2016-11-22
In this paper, we demonstrate three-dimensional (3D) integrated circuits (ICs) based on a 3D complementary organic field-effect transistor (3D-COFET). The transistor-on-transistor structure was achieved by vertically stacking a p-type OFET over an n-type OFET with a shared gate joining the two transistors, effectively halving the footprint of printed transistors. All the functional layers including organic semiconductors, source/drain/gate electrodes, and interconnection paths were fully inkjet-printed except a parylene dielectric which was deposited by chemical vapor deposition. An array of printed 3D-COFETs and their inverter logic gates comprising over 100 transistors showed 100% yield, and the uniformity and long-term stability of the device were also investigated. A full-adder circuit, the most basic computing unit, has been successfully demonstrated using nine NAND gates based on the 3D structure. The present study fulfills the essential requirements for the fabrication of organic printed complex ICs (increased transistor density, 100% yield, high uniformity, and long-term stability), and the findings can be applied to realize more complex digital/analogue ICs and intelligent devices.
Short- and Long-Term Sleep Stability in Insomniacs and Healthy Controls
Gaines, Jordan; Vgontzas, Alexandros N.; Fernandez-Mendoza, Julio; Basta, Maria; Pejovic, Slobodanka; He, Fan; Bixler, Edward O.
2015-01-01
Study Objectives: Assess the short- and long-term stability of sleep duration in patients with insomnia and normal-sleeping controls. Design: Observational short-term and prospective studies. Setting: Sleep laboratory. Participants: Patients with insomnia (n = 150) and controls (n = 151) were recruited from the local community or sleep disorders clinic. A subsample of 95 men from the Penn State Adult Cohort (PSAC) were followed up 2.6 y after their initial visit. Measurements: Participants underwent a physical examination and 8-h polysomnography (PSG) recording for 3 consecutive nights (controls and insomniacs), or 2 single nights separated by several years (PSAC). Intraclass correlation coefficients (ICCs) assessed the stability of the variables total sleep time (TST), sleep onset latency (SOL), and wake after sleep onset (WASO). We also examined persistence of the first-night classification of “short” versus “normal” sleep duration on subsequent nights. Results: Stability of TST, SOL, and WASO based on 1 night were slight to moderate in both patients with insomnia (ICC = 0.37–0.57) and controls (ICC = 0.39–0.59), and became substantial to almost perfect when based on the average of 3 nights (ICC = 0.64–0.81). We observed similar degrees of stability for TST and WASO in the longitudinal sample, with moderate stability based on a single night and substantial stability based on both nights. In examining the persistence of “short” and “normal” sleep duration, 71.4% (controls), 74.7% (patients with insomnia), and 72.6% (longitudinal sample) of participants retained their first-night classifications over subsequent nights. Conclusions: Sleep duration variables, particularly total sleep time based on 3 consecutive nights in both patients with insomnia and controls or two single-night recordings separated by several years, are stable and reflect a person's habitual sleep. Furthermore, a single night in the laboratory may be useful for reliably classifying one's sleep duration. Citation: Gaines J, Vgontzas AN, Fernandez-Mendoza J, Basta M, Pejovic S, He F, Bixler EO. Short- and long-term sleep stability in insomniacs and healthy controls. SLEEP 2015;38(11):1727–1734. PMID:26237768
Biomechanical Concepts for Fracture Fixation
Bottlang, Michael; Schemitsch, Christine E.; Nauth, Aaron; Routt, Milton; Egol, Kenneth; Cook, Gillian E.; Schemitsch, Emil H.
2015-01-01
Application of the correct fixation construct is critical for fracture healing and long-term stability; however, it is a complex issue with numerous significant factors. This review describes a number of common fracture types, and evaluates their currently available fracture fixation constructs. In the setting of complex elbow instability, stable fixation or radial head replacement with an appropriately sized implant in conjunction with ligamentous repair is required to restore stability. For unstable sacral fractures, “standard” iliosacral screw fixation is not sufficient for fractures with vertical or multiplanar instabilities. Periprosthetic femur fractures, in particular Vancouver B1 fractures, have increased stability when using 90/90 fixation versus a single locking plate. Far Cortical Locking combines the concept of dynamization with locked plating in order to achieve superior healing of a distal femur fracture. Finally, there is no ideal construct for syndesmotic fracture stabilization; however, these fractures should be fixed using a device that allows for sufficient motion in the syndesmosis. In general, orthopaedic surgeons should select a fracture fixation construct that restores stability and promotes healing at the fracture site, while reducing the potential for fixation failure. PMID:26584263
Rosmalen, Judith G M; Kema, Ido P; Wüst, Stefan; van der Ley, Claude; Visser, Sipke T; Snieder, Harold; Bakker, Stephan J L
2014-09-01
Function of the hypothalamus-pituitary-adrenal (HPA) axis has been associated with several somatic and psychiatric health problems. The amount of free cortisol excreted in the urine during 24h (24-h UFC) has often been used as a proxy for HPA-axis function. Reference values for 24-h UFC and their stability in the short and long term, as well as sources of variability, are largely lacking. This study was performed in a general population cohort. Participants collected 24-h UFC on two consecutive days (T1), and repeated this collection approximately 2 years later (T2). Cortisol in urine was measured using LC-MS/MS. Height and weight were measured at the research facilities; glomerular filtration rate was estimated using creatinine clearance. Psychological distress (General Health Questionnaire), smoking, alcohol use and exercise were measured by means of questionnaires. 24-h UFC stability on a day-to-day basis was 0.69 (T1, N=1192) and 0.72 (T2, N=963) (both p<0.001). Long-term stability as indicated by correlation between 2-day averages of T1 and T2 was 0.60 (N=972, p<0.001). Multivariable linear regression analysis revealed that 24-h UFC was predicted by urine volume (standardized beta 0.282 (T1, N=1556) and 0.276 (T2, N=1244); both p<0.001) and glomerular filtration rate (standardized beta 0.137 (T1) and 0.179 (T2); both p<0.001), while also sex explained a small part (standardized beta for female sex -0.057 (T1) and -0.080 (T2); both p<0.05). 24-h UFC is moderately stable both in the short and the long term. The effects of urine volume and glomerular filtration rate on 24-h UFC are much stronger than those of sex. Copyright © 2014 Elsevier Ltd. All rights reserved.
Zhang, Qiang; Suh, Wonmo; Pan, Zui; You, Guofeng
2012-01-01
Human organic anion transporter 3 (hOAT3) belongs to a family of organic anion transporters that play critical roles in the body disposition of numerous clinically important drugs. Therefore, understanding the regulation of this transporter has profound clinical significance. In the current study, we investigated the short-term and long-term regulation of hOAT3 by protein kinase C (PKC). We showed that short-term activation of PKC by phobol 12-Myristate 13-Acetate (PMA) inhibited hOAT3 activity through accelerating its internalization from cell surface to intracellular recycling endosomes. The colocalization of hOAT3 with EEA1-positive recycling endosomes was demonstrated by immunolocalization with confocal microscopy. Furthermore, we showed that long-term activation of PKC resulted in the enhanced degradation of cell surface hOAT3. The pathways for hOAT3 degradation were further examined using proteasomal and lysosomal inhibitors. Our results showed that both proteasomal inhibitors and the lysosomal inhibitors significantly blocked hOAT3 degradation. These results demonstrate that PKC plays critical roles in the trafficking and the stability of hOAT3. PMID:22773962
Long-term stability of self-assembled monolayers on 316L stainless steel.
Kaufmann, C R; Mani, G; Marton, D; Johnson, D M; Agrawal, C M
2010-04-01
316L stainless steel (316L SS) has been extensively used for making orthopedic, dental and cardiovascular implants. The use of phosphonic acid self-assembled monolayers (SAMs) on 316L SS has been previously explored for potential biomedical applications. In this study, we have investigated the long-term stability of methyl (-CH(3)) and carboxylic acid (-COOH)-terminated phosphonic acid SAMs on 316L under physiological conditions. The stability of SAMs on mechanically polished and electropolished 316L SS was also investigated as a part of this study. Well-ordered and uniform -CH(3)- and -COOH-terminated SAMs were coated on mechanically polished and electropolished 316L SS surfaces. The long-term stability of SAMs on 316L SS was investigated for up to 28 days in Tris-buffered saline (TBS) at 37 degrees C using x-ray photoelectron spectroscopy, atomic force microscopy and contact angle goniometry. A significant amount of phosphonic acid molecules was desorbed from the 316L SS surfaces within 1 to 7 days of TBS immersion followed by a slow desorption of molecules over the remaining days. The -COOH-terminated SAM was found to be more stable than the -CH(3)-terminated SAM on both mechanically and electropolished surfaces. No significant differences in the desorption behavior of SAMs were observed between mechanically and electropolished 316L SS surfaces.
Optical Stabilization of a Microwave Oscillator for Fountain Clock Interrogation.
Lipphardt, Burghard; Gerginov, Vladislav; Weyers, Stefan
2017-04-01
We describe an optical frequency stabilization scheme of a microwave oscillator that is used for the interrogation of primary cesium fountain clocks. Because of its superior phase noise properties, this scheme, which is based on an ultrastable laser and a femtosecond laser frequency comb, overcomes the frequency instability limitations of fountain clocks given by the previously utilized quartz-oscillator-based frequency synthesis. The presented scheme combines the transfer of the short-term frequency instability of an optical cavity and the long-term frequency instability of a hydrogen maser to the microwave oscillator and is designed to provide continuous long-term operation for extended measurement periods of several weeks. The utilization of the twofold stabilization scheme on the one hand ensures the referencing of the fountain frequency to the hydrogen maser frequency and on the other hand results in a phase noise level of the fountain interrogation signal, which enables fountain frequency instabilities at the 2.5 ×10 -14 (τ/s) -1/2 level that are quantum projection noise limited.
Holman, Benjamin W B; Coombs, Cassius E O; Morris, Stephen; Bailes, Kristy; Hopkins, David L
2018-02-01
Lipid oxidation and fatty acid (FA) profiles were evaluated for beef M. longissimus lumborum (LL) stored under different chilled-then-frozen storage combinations (up to 5 and 52weeks, respectively) and two frozen holding temperatures (-12°C and -18°C). FA profile variation was observed, with increasing frozen storage periods resulting in unsaturated FA levels declining as saturated FA levels increased. Polyunsaturated and health claimable FA levels also tended to decline with increasing chilled storage period, albeit insignificant within the constraints of the experimental design. Peroxidase activity, TBARS and oxidation-reduction potential analyses reflected these FA changes. These, when compared against existing consumer thresholds, suggest a perceptible detraction from LL held under long-term frozen storage durations that are less evident earlier as dependent on the preceding chilled storage period. Negligible impact of frozen storage holding temperatures was observed on measured traits. These results suggest long-term chilled-then-frozen storage can influence beef lipid stability, healthy FA profile and therefore the healthiness of beef. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Soil stabilization with recycled materials improves subgrade performance : research spotlight.
DOT National Transportation Integrated Search
2016-02-29
The use of recycled materials for subgrade stabilization can provide the support needed for construction vehicle loading and more typical long-term traffic loading. This is a particular need in Michigan due to the prevalence of weak subgrade soils. U...
Understanding Price Formation in Electricity Markets
NASA Astrophysics Data System (ADS)
Kadoya, Toshihisa; Sasaki, Tetsuo; Yokoyama, Akihiko; Ihara, Satoru
The electricity price will influence the future growth and mix of generation capacity that will in turn influence the future electricity price, and therefore, it is important to understand how electricity price is formed as well as its short-term and long-term impacts on the economy. This paper describes evaluation of PJM day-ahead market bidding data and comparison of various electricity markets in terms of the market clearing price and volatility. The objective is to find critical factors and mechanisms determining the movements of electricity price. It was found that speculation by a small number of bidders can cause price spikes, that a Nash equilibrium may exist during a delayed response of the electricity price to a decline of the fuel price, and that the hydro generation with storage capability effectively stabilizes the electricity price.
Long term contracts, expansion, innovation and stability: North Dakota's lignite mines thrive
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buchsbaum, L.
2009-08-15
North Dakota's lignite coal industry is mainly located in three countries in the central part of the state. Its large surface lignite mines are tied through long-term (20-40 years) contracts to power plants. The article talks about operations at three of the most productive mines - the Freedom mine, Falkirk mine and Center Mine. 4 figs.
Terrier, Philippe; Dériaz, Olivier
2013-01-01
It has been observed that times series of gait parameters [stride length (SL), stride time (ST), and stride speed (SS)], exhibit long-term persistence and fractal-like properties. Synchronizing steps with rhythmic auditory stimuli modifies the persistent fluctuation pattern to anti-persistence. Another non-linear method estimates the degree of resilience of gait control to small perturbations, i.e., the local dynamic stability (LDS). The method makes use of the maximal Lyapunov exponent, which estimates how fast a non-linear system embedded in a reconstructed state space (attractor) diverges after an infinitesimal perturbation. We propose to use an instrumented treadmill to simultaneously measure basic gait parameters (time series of SL, ST, and SS from which the statistical persistence among consecutive strides can be assessed), and the trajectory of the center of pressure (from which the LDS can be estimated). In 20 healthy participants, the response to rhythmic auditory cueing (RAC) of LDS and of statistical persistence [assessed with detrended fluctuation analysis (DFA)] was compared. By analyzing the divergence curves, we observed that long-term LDS (computed as the reverse of the average logarithmic rate of divergence between the 4th and the 10th strides downstream from nearest neighbors in the reconstructed attractor) was strongly enhanced (relative change +73%). That is likely the indication of a more dampened dynamics. The change in short-term LDS (divergence over one step) was smaller (+3%). DFA results (scaling exponents) confirmed an anti-persistent pattern in ST, SL, and SS. Long-term LDS (but not short-term LDS) and scaling exponents exhibited a significant correlation between them (r = 0.7). Both phenomena probably result from the more conscious/voluntary gait control that is required by RAC. We suggest that LDS and statistical persistence should be used to evaluate the efficiency of cueing therapy in patients with neurological gait disorders.
Long-Term IQ Stability Using the WISC-IV and WAIS-IV among a Sample of Special Education Students
ERIC Educational Resources Information Center
Spector, Hayley
2013-01-01
The present study investigated the stability of scores on the WISC-IV and WAIS-IV over an approximate six-year period. Previous research using older versions of the WISC and WAIS have suggested that these scales demonstrate strong stability of scores. Since research that has compared the stability of scores between the WISC-IV and the WAIS-IV is…
Aggregative stability of fungicidal nanomodifier based on zinc hydrosilicates
NASA Astrophysics Data System (ADS)
Grishina, Anna; Korolev, Evgeniy
2018-03-01
Currently, there is a strong need of high performance multi functional materials in high-rise construction. Obviously, such materials should be characterized by high strength; but for interior rooms biosafety is important as well. The promising direction to obtain both high strength and maintain biosafety in buildings and structures is to manage the structure of mineral binders by means of fungicidal nanomodifier based on zinc hydrosilicates. In the present work the aggregative stability of colloidal solutions of zinc hydrosilicates after one year of storage was studied. It has been established that the concentration of iron (III) hydroxide used to prepare the precursor of zinc hydrosilicates has a significant effect on the long-term aggregative stability: as the concentration of iron (III) hydroxide increases, the resistance of the fungicidal nanomodifier increases. It was found that, despite the minimal concentration of nano-sized zinc hydrosilicates (0.028%), the colloidal solution possesses a low long-term aggregative stability; while in the initial period (not less than 14 days) the colloidal solution of the nanomodifier is aggregatively stable. It is shown that when the ratio in the colloidal solution of the amount of the substance CH3COOH / SiO2 = 0.43 is reached, an increase in the polymerization rate is observed, which is the main cause of low aggregative stability. Colloidal solutions containing zinc hydrosilicates synthesized at a concentration of iron (III) hydroxide used to produce a precursor equal to 0.7% have a long-term aggregative stability and do not significantly change the reduced particle. Such compositions are to be expediently used for the nanomodifying of building composites in order to control their structure formation and to create conditions that impede the development of various mycelial fungi.
Long-Term Muscle Fatigue After Standing Work.
Garcia, Maria-Gabriela; Läubli, Thomas; Martin, Bernard J
2015-11-01
The aims of this study were to determine long-term fatigue effects in the lower limbs associated with standing work and to estimate possible age and gender influences. The progressive accumulation of muscle fatigue effects is assumed to lead to musculoskeletal disorders, as fatigue generated by sustained low-level exertions exhibits long-lasting effects. However, these effects have received little attention in the lower limbs. Fourteen men and 12 women from two different age groups simulated standing work for 5 hr including 5-min seated rest breaks and a 30-min lunch. The younger group was also tested in a control day. Muscle fatigue was quantified by electrically induced muscle twitches (muscle twitch force [MTF]), postural stability, and subjective evaluation of discomfort. MTF showed a significant fatigue effect after standing work that persisted beyond 30 min after the end of the workday. MTF was not affected on the control day. The center of pressure displacement speed increased significantly over time after standing work but was also affected on the control day. Subjective evaluations of discomfort indicated a significant increase in perception of fatigue immediately after the end of standing work; however, this perception did not persist 30 min after. Age and gender did not influence fatigue. Objective measures show the long-term effects of muscle fatigue after 5 hr of standing work; however, this fatigue is no longer perceived after 30 min of rest postwork. The present results suggest that occupational activities requiring prolonged standing are likely to contribute to lower-extremity and/or back disorders. © 2015, Human Factors and Ergonomics Society.
Levitsky VYu; Panova, A A; Mozhaev, V V
1994-01-15
A correlation between the stability of alpha-chymotrypsin against irreversible thermal inactivation at high temperatures (long-term stability) and the coefficient of Setchenov equation as a measure of salting-in/out efficiency of solutes in the Hofmeister series has been found. An increase in the concentration of salting-in solutes (KSCN, urea, guanidinium chloride, formamide) leads to a many-fold decrease of the inactivation rate of the enzyme. In contrast, addition of salting-out solutes has a small effect on the long-term stability of alpha-chymotrypsin at high temperatures. The effects of solutes are additive with respect to their salting-in/out capacities; the stabilizing action of the solutes is determined by the calculated Setchenov coefficient of solution. The correlation is explained by a solute-driven shift of the conformational equilibrium between the 'low-temperature' native and the 'high-temperature' denatured forms of the enzyme within the range of the kinetic scheme put forward in the preceding paper in this journal: irreversible inactivation of the high-temperature form proceeds much more slowly compared with the low-temperature form.
Evaluation of a Salutogenetic Concept for Inpatient Psychosomatic Treatment
Loew, Thomas
2013-01-01
The increase of psychosomatic disorders due to cultural changes requires enhanced therapeutic models. This study investigated a salutogenetic treatment concept for inpatient psychosomatic treatment, based on data from more than 11000 patients of a psychosomatic clinic in Germany. The clinic aims at supporting patients' health improvement by fostering values such as humanity, community, and mindfulness. Most of patients found these values realized in the clinical environment. Self-assessment questionnaires addressing physical and mental health as well as symptom ratings were available for analysis of pre-post-treatment effects and long-term stability using one-year follow-up data, as well as for a comparison with other clinics. With respect to different diagnoses, symptoms improved in self-ratings with average effect sizes between 0.60 and 0.98. About 80% of positive changes could be sustained as determined in a 1-year follow-up survey. Patients with a lower concordance with the values of the clinic showed less health improvement. Compared to 14 other German psychosomatic clinics, the investigated treatment concept resulted in slightly higher decrease in symptoms (e.g., depression scale) and a higher self-rated mental and physical improvement in health. The data suggest that a successfully implemented salutogenetic clinical treatment concept not only has positive influence on treatment effects but also provides long-term stability. PMID:24159352
NASA Astrophysics Data System (ADS)
Karkarey, R.; Kelkar, N.; Lobo, A. Savio; Alcoverro, T.; Arthur, R.
2014-06-01
Benthic recovery from climate-related disturbances does not always warrant a commensurate functional recovery for reef-associated fish communities. Here, we examine the distribution of benthic groupers (family Serranidae) in coral reef communities from the Lakshadweep archipelago (Arabian Sea) in response to structural complexity and long-term habitat stability. These coral reefs that have been subject to two major El Niño Southern Oscillation-related coral bleaching events in the last decades (1998 and 2010). First, we employ a long-term (12-yr) benthic-monitoring dataset to track habitat structural stability at twelve reef sites in the archipelago. Structural stability of reefs was strongly driven by exposure to monsoon storms and depth, which made deeper and more sheltered reefs on the eastern aspect more stable than the more exposed (western) and shallower reefs. We surveyed groupers (species richness, abundance, biomass) in 60 sites across the entire archipelago, representing both exposures and depths. Sites were selected along a gradient of structural complexity from very low to high. Grouper biomass appeared to vary with habitat stability with significant differences between depth and exposure; sheltered deep reefs had a higher grouper biomass than either sheltered shallow or exposed (deep and shallow) reefs. Species richness and abundance showed similar (though not significant) trends. More interestingly, average grouper biomass increased exponentially with structural complexity, but only at the sheltered deep (high stability) sites, despite the availability of recovered structure at exposed deep and shallow sites (lower-stability sites). This trend was especially pronounced for long-lived groupers (life span >10 yrs). These results suggest that long-lived groupers may prefer temporally stable reefs, independent of the local availability of habitat structure. In reefs subject to repeated disturbances, the presence of structurally stable reefs may be critical as refuges for functionally important, long-lived species like groupers.
Best practices of using shotcrete for wall fascia and slope stabilization (phase 1 study)
DOT National Transportation Integrated Search
2017-06-01
Shotcrete has become attractive and holds potential to replace cast-in-place (CIP) concrete for elements like retaining walls and slope stabilization. However, this practice is still limited due to concerns of drying shrinkage cracking, long-term dur...
Long term benefits of stabilizing soil subgrades
DOT National Transportation Integrated Search
2002-06-01
Chemical admixtures have been used extensively since the mid-eighties in Kentucky to improve bearing strengths of soil subgrades. Most pavements in Kentucky are constructed on clayey soils. Although short-term observations at a small number of sites ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, A. J.; Voss, L. F.; Beck, P. R.
We subjected device-grade TlBr to various chemical treatments used in room temperature radiation detector fabrication to determine the resulting surface composition and electronic structure. As-polished TlBr was treated separately with HCl, SOCl 2, Br:MeOH and HF solutions. High-resolution photoemission measurements on the valence band electronic structure and Tl 4f, Br 3d, Cl 2p and S 2p core lines were used to evaluate surface chemistry and shallow heterojunction formation. Surface chemistry and valence band electronic structure were correlated with the goal of optimizing the long-term stability and radiation response.
Olesiński, Tomasz; Szpakowski, Marek; Saramak, Piotr; Rutkowski, Andrzej; Jeziorski, Krzysztof
2017-10-01
The aim of this prospective study was to compare subjective and objective quality of life (QoL) of gastric cancer patients after total gastrectomy with and without preservation of the duodenal passage during short- and long-term follow-up. The study included 68 patients, among them 37 (54%) persons subjected to total gastrectomy with Roux-Y reconstruction (R-Y group) and 31 (46%) individuals in whom gastrectomy was followed by formation of Henley-Longmire loop (H-L group). Subjective and objective QoL was determined 1 and 10 years postsurgery. During each visit, subjective QoL was determined with EORTC QLQ-C30 questionnaire, along with markers of nutritional status and self-reported incidence of symptoms specific to postgastrectomy syndrome. The two groups did not differ significantly in terms of their subjective QoL and markers of nutritional status at 1 and 10 years postsurgery, and none of these parameters underwent significant changes between the first and second evaluation. Patients from R-Y group reported subjective weight loss significantly more often during both visits, and individuals from H-L group significantly more often complained on postprandial diarrhea during long-term follow-up. Moreover, both groups showed an increase in the incidence of postprandial vomiting between the first and second evaluation. QoL of gastric cancer patients subjected to total gastrectomy stabilizes at relatively high level within a year from the surgery. Preservation of the duodenal passage does not exert a beneficial effect on both objective and subjective QoL after total gastrectomy.
Microstructural Changes in Inconel ® 740 After Long-Term Aging in the Presence and Absence of Stress
Unocic, Kinga A.; Shingledecker, John Paul; Tortorelli, Peter F.
2014-11-18
The Ni-based alloy, Inconel ® 740, is being extensively examined for use in advanced ultrasupercritical steam boilers because its precipitation-strengthened microstructure appears to offer the necessary creep strength under the high temperatures and pressures (up to 760°C and 35 MPa) needed for high efficiency power generation. However, because this application requires extremely long lifetimes under these conditions (up to 30 years), long-term microstructure stability is a major concern. In this study, results from microstructural analyses of Inconel 740 specimens aged at 700 and 750°C in the presence and absence of creep loading for times up to ~31,000 h are presented.more » The primary focus was on the development of the eta η (Ni 3Ti) phase and coarsening of coherent γ'-Ni 3(Al,Ti) precipitates and its depletion near eta/matrix interfaces. Finally, however, despite these processes, Inconel 740 showed adequate long-term microstructural stability to assure adequate creep strength for the intended application.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruggiero, C. E.; Twary, S. N.; Deladurantaye, E.
2003-01-01
In recognition of the need for a safe, effective technology for long term Pu/Th/Actinide stabilization or removal from soils, we have begun an investigation of the potential for phytoremediation (phytostabilization and/or phytoextraction) of Pu and other actinide soil contaminants at DOE sites using phytosiderophore producing plants, and are investigating the contribution of phytosiderophores to actinide mobility in the subsurface environment. Phytoremediation and Phytostabilization have been proven to be a cost-effective, safe, efficient, and publicly acceptable technology for clean up and/or stabilization of contaminant metals . However, no phyto-based technologies have been developed for stabilization or removal of plutonium from soilsmore » and groundwater, and very few have been investigated for other actinides . Current metal-phytostabilization and phytoremediation techniques, predominately based around lead, nickel, and other soft-metal phytoextraction, will almost certainly be inadequate for plutonium due its distinct chemical properties . Phytosiderophore-based phytoremediation may provide technically and financially practical methods for remediation and long-term stewardship of soils that have low to moderate, near surface actinide contamination . We plan to demonstrate potential benefits of phytosiderophore-producing plants for long-term actinide contaminant stabilization by the plant's prevention of soil erosion and actinide migration through hydraulic control and/or through actinide removal through phytoextraction . We may also show possible harm caused by these plants through increased presence of actinide chelators that could increase actinide mobilization and migration in the subsurface environment. This information can then be directly applied by either removal of harmful plants, or be used to develop plant-based soil stabilization/remediation technologies .« less
Factors influencing botulinum toxin dose instability in spasmodic dysphonia patients.
Rosow, David E; Pechman, Amanda; Saint-Victor, Sandra; Lo, Kaming; Lundy, Donna S; Casiano, Roy R
2015-05-01
Many patients with spasmodic dysphonia (SD) see consistent effects from botulinum toxin (BTX) injections of the same dose, whereas others require dosage changes over time. We sought to determine whether demographics (age and gender) or environmental factors (smoking) affect the long-term stability of BTX dosing in these patients. Retrospective review. Charts of all patients undergoing BTX injection for adductor SD were reviewed. Dosage change, defined as whether there was any difference in total dosage used between two beneficial injections, was used as a measure of dosing stability. Beneficial injections were indicated by a voice rating score of at least three of four and any non-zero duration of improved voice. Logistic regression analysis was performed to determine whether age, gender, smoking status, or duration of treatment correlated with odds of having a dosage change. A total of 211 patients were ultimately included. Age, gender, and smoking status were all found to have no correlative effect on dosing stability. The only factor that was predictive of dose stability was the number of previous beneficial injections, as every additional injection led to decreased odds of a change in dosage for the next injection (odds ratio=0.964; 95% confidence interval=0.947-0.981). Dosage of BTX injections for long-term treatment of SD has a significant propensity to remain stable over time. Factors such as age, gender, and smoking status do not appear to influence the dosage stability. These findings should allow for better patient counseling regarding expectations for their long-term treatment. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Liang, B.; Weng, Y. T.; Wang, C. C.; Chiang, C. C.; Liu, C. C.; Lehmann, J.
2017-12-01
Black carbon receives increasing global wide research attention due to its role in carbon sequestration, soil fertility enhancement and remediation application. Generally considered chemically stable in bulk, the reactive surface of BC can interplays with minerals and form strong chemical bondage, which renders physical protection of BC and contributes to its long term stabilization. Using historical BC-rich Amazonian Dark Earth (ADE), we probe the in-situ organo-mineral association and transformation of BC and minerals over a millennium scale using various synchrotron-based spectroscopic (XANES, FTIR) and microscopic (TXM) methods. Higher content of SRO minerals was found in BC-rich ADE compare to adjacent tropical soils. The iron signature found in BC-rich ADE was mainly ferrihydrite/lepidocrocite, a more reactive form of Fe compared to goethite, which was dominant in adjacent soil. Abundant nano minerals particles were observed in-situ associated with BC surface, in clusters and layers. The organo-mineral interaction lowers BC bioavailability and enhances its long-term stabilization in environment, while at the same time, transforms associated minerals into more reactive forms under rapid redox/weathering environment. The results suggest that mineral physical protection for BC sequestration may be more important than previous understanding. The scale up application of BC/biochar into agricultural systems and natural environments have long lasting impact on the in-situ transformation of associated minerals.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-10
...-0-2A, National Fire Academy (NFA) Long-Term Evaluation Student/Trainee; FEMA Form 078-0-2, NFA Long... collection; OMB No. 1660-0039; FEMA Form 078-0-2A (Presently FEMA Form 95-59), NFA Long- Term Evaluation Student/Trainee; FEMA Form 078-0-2 (Presently FEMA Form 95-58), NFA Long-Term Evaluation Supervisors...
Zhou, Lan; Yan, Qimin; Yu, Jie; ...
2016-03-14
We discuss how deployment of solar fuels technology requires photoanodes and that long term stability, can be accomplished using light absorbers that self-passivate under operational conditions. We recently reported that several copper vanadates are promising photoanode materials, and their stability and self-passivation is demonstrated through a combination of Pourbaix calculations and combinatorial experimentation.
Chenevas-Paule, Clémence; Wolff, Hans-Michael; Ashton, Mark; Schubert, Martin; Dodou, Kalliopi
2017-05-01
Drug crystallization in transdermal drug delivery systems is a critical quality defect. The impact of drug load and hydration on the physical stability of polar (acrylic) drug-in-adhesive (DIA) films was investigated with the objective to identify predictive formulation parameters with respect to drug solubility and long-term stability. Medicated acrylic films were prepared over a range of drug concentrations below and above saturation solubility and were characterized by Fourier transform infrared spectroscopy, differential scanning calorimetry, polarized microscopy, and dynamic vapor sorption (DVS) analysis. Physical stability of medicated films was monitored over 4 months under different storage conditions and was dependent on solubility parameters, Gibbs free energy for drug phase transition from the amorphous to the crystalline state, and relative humidity. DVS data, for assessing H-bonding capacity experimentally, were essential to predict physical stability at different humidities and were used together with Gibbs free energy change and the Hoffman equation to develop a new predictive thermodynamic model to estimate drug solubility and stability in DIA films taking into account relative humidity. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Examining the long-term stability of overgeneral autobiographical memory.
Sumner, Jennifer A; Mineka, Susan; Zinbarg, Richard E; Craske, Michelle G; Vrshek-Schallhorn, Suzanne; Epstein, Alyssa
2014-01-01
Overgeneral autobiographical memory (OGM) is a proposed trait-marker for vulnerability to depression, but relatively little work has examined its long-term stability. This study investigated the stability of OGM over several years in 271 late adolescents and young adults participating in a larger longitudinal study of risk for emotional disorders. The Autobiographical Memory Test (AMT) was administered twice, with test-retest intervals ranging from approximately 3 to 6 years. There was evidence of significant but modest stability in OGM over several years. Specifically, Spearman rank correlations (ρs) between the proportions of specific and categoric memories generated on the two AMTs were .31 and .32, respectively. We did not find evidence that the stability of OGM was moderated by the length of the test-retest interval. Furthermore, the stability coefficients for OGM for individuals with and without a lifetime history of major depressive disorder (MDD) were relatively similar in magnitude and not significantly different from one another (ρs=.34 and .42 for the proportions of specific and categoric memories for those with a history of MDD; ρs=.31 for both the proportions of specific and categoric memories for those without a history of MDD). Implications for the conceptualisation of OGM are discussed.
NASA Astrophysics Data System (ADS)
Ohmae, Noriaki; Kuse, Naoya; Fermann, Martin E.; Katori, Hidetoshi
2017-06-01
All-polarization-maintaining, single-port Er:fiber combs offer long-term robust operation as well as high stability. We have built two such combs and evaluated the transfer noise for linking optical clocks. A uniformly broadened spectrum over 135-285 THz with a high signal-to-noise ratio enables the optical frequency measurement of the subharmonics of strontium, ytterbium, and mercury optical lattice clocks with the fractional frequency-noise power spectral density of (1-2) × 10-17 Hz-1/2 at 1 Hz. By applying a synchronous clock comparison, the comb enables clock ratio measurements with 10-17 instability at 1 s, which is one order of magnitude smaller than the best instability of the frequency ratio of optical lattice clocks.
Advanced Oxide Material Systems For 1650 C Thermal/Environmental Barrier Coating Applications
NASA Technical Reports Server (NTRS)
Zhu, Dongming; Fox, Dennis S.; Bansal, Narottam P.; Miller, Robert A.
2004-01-01
Advanced thermal/environmental barrier coatings (T/EBCs) are being developed for low emission SiC/SiC ceramic matrix composite (CMC) combustor and vane applications to extend the CMC liner and vane temperature capability to 1650 C (3000 F) in oxidizing and water-vapor containing combustion environments. The 1650 C T/EBC system is required to have better thermal stability, lower thermal conductivity, and improved sintering and thermal stress resistance than current coating systems. In this paper, the thermal conductivity, water vapor stability and cyclic durability of selected candidate zirconia-/hafnia-, pyrochlore- and magnetoplumbite-based T/EBC materials are evaluated. The test results have been used to downselect the T/EBC coating materials, and help demonstrate advanced 1650OC coatings feasibility with long-term cyclic durability.
Potentiometric sensors with carbon black supporting platinum nanoparticles.
Paczosa-Bator, Beata; Cabaj, Leszek; Piech, Robert; Skupień, Krzysztof
2013-11-05
For the first time, a single-piece, all-solid-state ion-selective electrode was fabricated with carbon black supporting platinum nanoparticles (PtNPs-CB) and a polymeric membrane. The PtNPs-CB, as an intermediate layer, was drop-casted directly on the solid substrate, and then an ionophore-doped solvent polymeric membrane was added in order to form a sensor. The performance of the newly developed electrodes was evaluated on the basis of potassium and nitrate ions. The stability of the electrical potential for the electrodes was examined by performing current-reversal chronopotentiometry, and the influence of the interfacial water film was assessed by the potentiometric aqueous-layer test. Fabricated potassium- and nitrate-selective electrodes displayed a Nernstian slope and several outstanding properties such as high long-term potential stability, potential repeatability, and reproducibility.
Biological activity studies of the novel glucagon-like peptide-1 derivative HJ07.
Han, Jing; Sun, Li-Dan; Qian, Hai; Huang, Wen-Long
2014-08-01
To identify the glucose lowering ability and chronic treatment effects of a novel coumarin-glucagon-like peptide-1 (GLP-1) conjugate HJ07. A receptor activation experiment was performed in HEK 293 cells and the glucose lowering ability was evaluated with hypoglycemic duration and glucose stabilizing tests. Chronic treatment was performed by daily injection of exendin-4, saline, and HJ07. Body weight and HbA1c were measured every week, and an intraperitoneal glucose tolerance test was performed before treatment and after treatment. HJ07 showed well-preserved receptor activation efficacy. The hypoglycemic duration test showed that HJ07 possessed a long-acting, glucose-lowering effect and the glucose stabilizing test showed that the antihyperglycemic activity of HJ07 was still evident at a predetermined time (12 h) prior to the glucose challenge (0 h). The long time glucose-lowering effect of HJ07 was better than native GLP-1 and exendin-4. Furthermore, once daily injection of HJ07 to db/db mice achieved long-term beneficial effects on HbA1c lowering and glucose tolerance. The biological activity results of HJ07 suggest that HJ07 is a potential long-acting agent for the treatment of type 2 diabetes. Copyright © 2014 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.
Sicilia, Alberto; Quirynen, Marc; Fontolliet, Alain; Francisco, Helena; Friedman, Anton; Linkevicius, Tomas; Lutz, Rainer; Meijer, Henny J; Rompen, Eric; Rotundo, Roberto; Schwarz, Frank; Simion, Massimo; Teughels, Wim; Wennerberg, Ann; Zuhr, Otto
2015-09-01
Several surgical techniques and prosthetic devices have been developed in the last decades, aiming to improve aesthetic, hygienic and functional outcomes that may affect the peri-implant tissues, such as procedures of bone and soft tissue augmentation and the use of custom-made abutments of titanium and zirconium. Three systematic reviews, based on randomized clinical trials and prospective studies covering the above reported topics were analysed, and the detected evidence was exposed to interactive experts' discussion during the group's and general assembly's meetings of the 4th EAO Consensus Conference. The results are reported using the following abbreviations: S-T: short-term evidence, M-T: medium-term evidence; L-T: long-term evidence; LE: limited evidence. Soft tissue augmentation procedures may be indicated for the increase of soft tissue thickness and keratinized tissue, the reduction of interproximal peri-implant bone loss, and the coverage of shallow peri-implant soft tissue recessions (S-T, LE), L-T is lacking. Guided bone regeneration approaches (GBR) showed efficacy when used for ridge reconstruction after the complete healing of the soft tissues (S-T & L-T), and the stability of the augmented bone may play a role in the maintenance of the soft tissue position and dimensions (LE). No significant differences were observed between titanium and zirconia abutments when evaluating probing pocket depth, bleeding on probing, marginal bone levels and mucosal recessions. Zirconia abutments were associated with more biological complications but demonstrated superiority in terms of achieving natural soft tissue colour (S-T). © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Germain, Dominique P; Waldek, Stephen; Banikazemi, Maryam; Bushinsky, David A; Charrow, Joel; Desnick, Robert J; Lee, Philip; Loew, Thomas; Vedder, Anouk C; Abichandani, Rekha; Wilcox, William R; Guffon, Nathalie
2007-05-01
Fabry disease, an inherited deficiency of the lysosomal enzyme alpha-galactosidase A, causes progressive intralysosomal accumulation of globotriaosylceramide (GL-3) and premature death from renal, cardiac, and cerebrovascular manifestations. To determine the long-term safety and efficacy of recombinant human alpha-galactosidase A, an open-label, phase III extension study was conducted, involving 58 patients who had classic Fabry disease and completed a 20-wk, double-blind, randomized, placebo-controlled, phase III study of agalsidase beta and were transitioned to an extension trial to receive biweekly 1 mg/kg agalsidase beta for up to an additional 54 mo. GL-3 accumulation was evaluated in the capillary endothelia of the skin, kidney, and heart. Renal function was assessed. By month 54, all patients with optional kidney biopsies (n = 8) maintained complete GL-3 clearance in renal capillary endothelial cells and multiple cell types. Continued, complete clearance of skin (31 of 36) and heart (six of eight) capillary endothelium was demonstrated. Mean plasma GL-3 levels remained decreased in the normal range. Median serum creatinine and estimated GFR remained stable (normal) in patients with renal data at month 54 (n = 41). Six patients had renal disease progression; most (four of six) were older than 40 yr and had significant proteinuria at baseline and evidence of sclerotic glomeruli pretreatment. Adverse events were generally mild and unrelated to treatment. The most common treatment-related adverse events were infusion-associated reactions, which decreased over time. Long-term agalsidase beta therapy stabilizes renal function in patients without renal involvement at baseline, maintains reduction of plasma GL-3, and sustains GL-3 clearance in capillary endothelial cells and multiple renal cell types.
Chung, Jin Kwon; Kim, Jin Kook; Lee, Jae Bum; Lee, Sung Jin
2013-10-01
To assess the efficacy and safety of iris-fixated phakic intraocular lens (pIOL) implantation to correct myopia in eyes with previous retinal detachment (RD) surgery. Department of Ophthalmology, Soonchunhyang University College of Medicine, Seoul, South Korea. Retrospective case series. Patients having pIOL implantation in both eyes were enrolled. Eyes that had scleral buckling or encircling (RD group) and healthy fellow eyes (non-RD group) were evaluated over a 6-year follow-up. The corrected distance visual acuity (CDVA), endothelial cell density (ECD), intraoperative complications, and long-term complications were safety outcomes. Uncorrected distance visual acuity (UDVA), predictability, and stability of refraction were efficacy outcomes. The study comprised 34 eyes (17 patients). The mean postoperative CDVA and ECD were not significantly different between groups, and no patient lost CDVA. The rate of transient intraocular pressure spike was significantly higher in the RD group (P=.043). After 3 years and 6 years, the mean postoperative UDVA was 0.06 logMAR ± 0.09 (SD) and 0.08 ± 0.10 logMAR, respectively, in the RD group and 0.04 ± 0.08 logMAR and 0.04 ± 0.09 logMAR, respectively, in the non-RD group (P=.518 and P=.478, respectively). The rate of eyes within ±0.50 diopter of the desired refraction and the postoperative refraction was not significantly different between groups. No eye had vitreoretinal changes requiring secondary surgical intervention. Iris-fixated pIOL implantation corrected the myopic refractive error in patients who had scleral buckling or encircling surgery for RD with a high degree of efficacy, safety, and long-term stability. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Erickson, Michael J; Barnes, Charles R; Henderson, Matthew R; Romagnoli, Robert; Firstenberg, Clifford E
2007-04-01
Analysis of site geomorphology and sedimentation rates as an indicator of long-term bed stability is central to the evaluation of remedial alternatives for depositional aquatic environments. In conjunction with various investigations of contaminant distribution, sediment dynamics, and bed stability in the Passaic River Estuary, 121 sediment cores were collected in the early 1990s from the lower 9.7 km of the Passaic River and analyzed for lead-210 (210Pb), cesium-137 (137Cs), and other analytes. This paper opportunistically uses the extensive radiochemical dataset to examine the spatial patterns of long-term sedimentation rates in, and associated geomorphic aspects of, this area of the river. For the purposes of computing sedimentation rates, the utility of the 210Pb and 137Cs depositional profiles was assessed to inform appropriate interpretation. Sedimentation rates were computed for 90 datable cores by 3 different methods, depending on profile utility. A sedimentation rate of 0 was assigned to 17 additional cores that were not datable and for which evidence of no deposition exists. Sedimentation patterns were assessed by grouping results within similar geomorphic areas, delineated through inspection of bathymetric data. On the basis of channel morphology, results reflect expected patterns, with the highest sedimentation rates observed along point bars and channel margins. The lowest rates of sedimentation (and the largest percentage of undatable cores) were observed in the areas along the outer banks of channel bends. Increasing sedimentation rates from upstream to downstream were noted. Average and median sedimentation rates were estimated to be 3.8 and 3.7 cm/y, respectively, reflecting the highly depositional nature of the Passaic River estuary. This finding is consistent with published descriptions of long-term geomorphology for Atlantic Coastal Plain estuaries.
Yan, Jiun-Lin; Chang, Chen-Nen; Chuang, Chi-Cheng; Hsu, Peng-Wei; Lin, Jen-Der; Wei, Kuo-Chen; Lee, Shi-Tseng; Tseng, Jen-Kan; Pai, Ping-Ching; Chen, Yao-Liang
2013-07-01
Radiotherapy is a crucial treatment for acromegalic patients with growth hormone (GH)-secreting pituitary tumors. However, its effect takes time. We retrospectively reviewed the long-term outcome of linear accelerator stereotactic radiosurgery (LINAC SRS) for patients with acromegaly from the perspective of biochemical remission and associated factors. Twenty-two patients presenting with residual or recurrent (GH)-secreting functional pituitary tumor between 1994 and 2004 who received LINAC SRS were enrolled and followed up for at least 3 years. Residual or recurrent tumor was defined as persistent elevated GH or insulin-like growth factor-1 (IGF-1) level and image-confirmed tumor after previous surgical treatment. Biochemical remission was defined as fasting GH less than 2.5 ng/mL with normal sex-and-age adjusted IGF-1. The mean follow-up period was 94.7 months (range 36-161 months). Overall mean biochemical remission time was 53 months (median 30 months). Biochemical control was achieved in 15 patients (68.2%) over the follow up period. One patient experienced recurrence after SRS and underwent another operation. Initial GH at diagnosis and pre-SRS GH correlated with biochemical control (p = 0.005 and p < 0.0001, respectively). Further evaluation demonstrated that biochemical control stabilized after 7.5 years. Overall post-SRS hormone deficit persisted in five patients (22.7%). In comparison to other radiosurgery modalities, LINAC radiosurgery also provides a satisfactory outcome. SRS has maximum effect over the first 2 years and stabilizes after 7.5 years. Moreover, SRS elicits long-term biochemical effects and requires longer follow-up for better biochemical remission. Copyright © 2012. Published by Elsevier B.V.
Long-term stability of dental adhesive incorporated by boron nitride nanotubes.
Degrazia, Felipe Weidenbach; Leitune, Vicente Castelo Branco; Visioli, Fernanda; Samuel, Susana Maria Werner; Collares, Fabrício Mezzomo
2018-03-01
The aim of this study was to evaluate physicochemical properties, long-term microtensile bond strength and cytotoxicity of methacrylate-based adhesive containing boron nitride nanotubes (BNNTs) as fillers. A dental adhesive was formulated using BisGMA/HEMA, 66/33wt% (control). Inorganic BNNT fillers were incorporated into the adhesive at different concentrations (0.05, 0.075, 0.1 and 0.15wt%). Analyses of degree of conversion (DC), polymerization rate [Rp.(s -1 )], contact angle (CA) on dentin, after 24h and 6 months microtensile bond strength (μTBS-24h and 6 months) were assessed. Cytotoxicity was performed through viability of fibroblast cells (%) by sulforhodamine B (SRB) colorimetry. DC and max. polymerization rate increased (p<0.05) after incorporating 0.075 and 0.1wt% BNNT. The contact angle on dentin increased (p<0.05) after incorporating 0.15wt% BNNT. The μTBS-24h showed no changes (p>0.05) after incorporating up to 0.15wt% BNNT comparing to control. After 6 months, μTBS decreased (p<0.05) for control and 0.15wt% BNNT and BNNT groups up to 0.15wt% showed higher μTBS than control (p<0.05). No difference of fibroblast growth was found among adhesives (p>0.05) and up to 19% of cell viability was found comparing 0.05wt% BNNT to positive control group (100%). Incorporating boron nitride nanotubes up to 0.1wt% into dental adhesive increased the long-term stability to dentin without decreasing viability of fibroblast cell growth. Thus, the use of BNNTs as filler may decrease failure rate of current dentinal adhesives. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Brody, Gene H.; Yu, Tianyi; Chen, Yi-fu; Kogan, Steven M.; Smith, Karen
2012-01-01
Objective: This report addresses the long-term efficacy of the Adults in the Making (AIM) prevention program on deterring the escalation of alcohol use and development of substance use problems, particularly among rural African American emerging adults confronting high levels of contextual risk. Method: African American youths (M age, pretest =…
Pandey, Pallavi; Kaur, Ranjeet; Singh, Sailendra; Chattopadhyay, Sunil Kumar; Srivastava, Santosh Kumar; Banerjee, Suchitra
2014-07-01
The effect of 6 years of cultivation and use of table-sugar (TS) on the biomass/terpene alkaloid productivities and rol gene expression were studied in a hairy root (HR) clone of Rauvolfia serpentina. The media cost could be reduced >94 % by replacing sucrose (SUC) with TS—an unexplored avenue for HR cultivation. The overall productivities increased over long-term cultivation with sugar proving superior to SUC for biomass (24.4 ± 2.11 g/l DW after 40 days to 17.31 % higher) and reserpine (0.094 ± 0.008 % DW after 60 days to 193.8 % more) production. The latter however revealed comparatively better yields concerning ajmaline (0.507 ± 0.048 % DW after 60 days to 61.98 % higher) and yohimbine (0.628 ± 0.062 % DW after 60 days to 38.32 % higher), respectively. PCR amplification of rol genes confirmed long-term expression stability.
Stability testing on typical flavonoid containing herbal drugs.
Heigl, D; Franz, G
2003-12-01
The aim of the presented work was to examine possible changes in the flavonoid pattern of common flavonoid containing herbal drugs during long term and stress testing storage periods. HPLC fingerprint was used to demonstrate the differences in stability of individual flavonoid components. In addition, the total flavonoid content was determined according to the pharmacopoeial photometrical method. Drug material was stored according to the ICH-guidelines at 25 degrees C and 60% rh (relative humidity) for long term testing over a 24 months period or at 40 degrees C and 75% rh under stress conditions for 6 months. Increased temperatures of 80 degrees C and 100 degrees C were chosen to elucidate possible instabilities of selected flavonoids. As an overall result, during long term testing, no significant changes in the flavonoid pattern can be detected. However, some flavonoid containing herbal drugs (e.g. birch leaves), showed a decrease of most flavonoids when stored at high temperature by an increase in the respective aglycones. Similar results were obtained during storage at 40 degrees C/75% rh.
Proceedings of the 6. international conference on stability and handling of liquid fuels. Volume 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giles, H.N.
1998-12-01
Volume 1 of these proceedings contain 29 papers related to aviation fuels and long term and strategic storage. Studies investigated fuel contamination, separation processes, measurement techniques, thermal stability, compatibility with fuel system materials, oxidation reactions, and degradation during storage.
Craven, S.W.; Peterson, J.T.; Freeman, Mary C.; Kwak, T.J.; Irwin, E.
2010-01-01
Modifications to stream hydrologic regimes can have a profound influence on the dynamics of their fish populations. Using hierarchical linear models, we examined the relations between flow regime and young-of-year fish density using fish sampling and discharge data from three different warmwater streams in Illinois, Alabama, and Georgia. We used an information theoretic approach to evaluate the relative support for models describing hypothesized influences of five flow regime components representing: short-term high and low flows; short-term flow stability; and long-term mean flows and flow stability on fish reproductive success during fish spawning and rearing periods. We also evaluated the influence of ten fish species traits on fish reproductive success. Species traits included spawning duration, reproductive strategy, egg incubation rate, swimming locomotion morphology, general habitat preference, and food habits. Model selection results indicated that young-of-year fish density was positively related to short-term high flows during the spawning period and negatively related to flow variability during the rearing period. However, the effect of the flow regime components varied substantially among species, but was related to species traits. The effect of short-term high flows on the reproductive success was lower for species that broadcast their eggs during spawning. Species with cruiser swimming locomotion morphologies (e.g., Micropterus) also were more vulnerable to variable flows during the rearing period. Our models provide insight into the conditions and timing of flows that influence the reproductive success of warmwater stream fishes and may guide decisions related to stream regulation and management. ?? 2010 US Government.
Riginos, Corinna; Porensky, Lauren M; Veblen, Kari E; Young, Truman P
2018-03-01
Rainfall and herbivory are fundamental drivers of grassland plant dynamics, yet few studies have examined long-term interactions between these factors in an experimental setting. Understanding such interactions is important, as rainfall is becoming increasingly erratic and native wild herbivores are being replaced by livestock. Livestock grazing and episodic low rainfall are thought to interact, leading to greater community change than either factor alone. We examined patterns of change and stability in herbaceous community composition through four dry periods, or droughts, over 15 years of the Kenya Long-term Exclosure Experiment (KLEE), which consists of six different combinations of cattle, native wild herbivores (e.g., zebras, gazelles), and mega-herbivores (giraffes, elephants). We used principal response curves to analyze the trajectory of change in each herbivore treatment relative to a common initial community and asked how droughts contributed to community change in these treatments. We examined three measures of stability (resistance, variability, and turnover) that correspond to different temporal scales and found that each had a different response to grazing. Treatments that included both cattle and wild herbivores had higher resistance (less net change over 15 years) but were more variable on shorter time scales; in contrast, the more lightly grazed treatments (no herbivores or wild herbivores only) showed lower resistance due to the accumulation of consistent, linear, short-term change. Community change was greatest during and immediately after droughts in all herbivore treatments. But, while drought contributed to directional change in the less grazed treatments, it contributed to both higher variability and resistance in the more heavily grazed treatments. Much of the community change in lightly grazed treatments (especially after droughts) was due to substantial increases in cover of the palatable grass Brachiaria lachnantha. These results illustrate how herbivory and drought can act together to cause change in grassland communities at the moderate to low end of a grazing intensity continuum. Livestock grazing at a moderate intensity in a system with a long evolutionary history of grazing contributed to long-term stability. This runs counter to often-held assumptions that livestock grazing leads to directional, destabilizing shifts in grassland systems. © 2017 by the Ecological Society of America.
Long-Term Stability of Planets in the Alpha Centauri System
NASA Technical Reports Server (NTRS)
Lissauer, Jack; Quarles, Billy
2015-01-01
The alpha Centauri system is billions of years old, so planets are only expected to be found in regions where their orbits are long-lived. We evaluate the extent of the regions within the alpha Centauri AB star system where small planets are able to orbit for billion-year timescales, and we map the positions in the sky plane where planets on stable orbits about either stellar component may appear. We confirm the qualitative results of Wiegert & Holman (Astron. J. 113, 1445, 1997) regarding the approximate size of the regions of stable orbits of a single planet, which are larger for retrograde orbits relative to the binary than for pro-grade orbits. Additionally, we find that mean motion resonances with the binary orbit leave an imprint on the limits of orbital stability, and the effects of the Lidov-Kozai mechanism are also readily apparent. Overall, orbits of a single planet in the habitable zones near the plane of the binary are stable, whereas high-inclination orbits are short-lived. However, even well within regions where single planets are stable, multiple planet systems must be significantly more widely-spaced than they need to be around an isolated star in order to be long-lived.
Structure, stability and behaviour of nucleic acids in ionic liquids
Tateishi-Karimata, Hisae; Sugimoto, Naoki
2014-01-01
Nucleic acids have become a powerful tool in nanotechnology because of their conformational polymorphism. However, lack of a medium in which nucleic acid structures exhibit long-term stability has been a bottleneck. Ionic liquids (ILs) are potential solvents in the nanotechnology field. Hydrated ILs, such as choline dihydrogen phosphate (choline dhp) and deep eutectic solvent (DES) prepared from choline chloride and urea, are ‘green’ solvents that ensure long-term stability of biomolecules. An understanding of the behaviour of nucleic acids in hydrated ILs is necessary for developing DNA materials. We here review current knowledge about the structures and stabilities of nucleic acids in choline dhp and DES. Interestingly, in choline dhp, A–T base pairs are more stable than G–C base pairs, the reverse of the situation in buffered NaCl solution. Moreover, DNA triplex formation is markedly stabilized in hydrated ILs compared with aqueous solution. In choline dhp, the stability of Hoogsteen base pairs is comparable to that of Watson–Crick base pairs. Moreover, the parallel form of the G-quadruplex is stabilized in DES compared with aqueous solution. The behaviours of various DNA molecules in ILs detailed here should be useful for designing oligonucleotides for the development of nanomaterials and nanodevices. PMID:25013178
Metrological properties of {CO 2}/{OsO 4} optical frequency standard
NASA Astrophysics Data System (ADS)
Acef, O.
1997-02-01
Recent progress on the metrological performance of the BNM-LPTF {CO 2}/{OsO 4} frequency standards in the {28}/{29}THz range, using OsO 4 molecular transitions as a frequency reference is reported. Significant improvements in terms of both short-term stability ( {6.6×10 -14}/{τup to τ=300s }) and long-term stability (4 × 10 -15 up to τ = 1 000 s, Δν ˜ 0.1 Hz) are obtained. Long term reproducibility (over more than 18 months) of about 3 × 10 -13 has been achieved. This high level enables the transfer, in terms of absolute frequency at the 3 × 10 -13 level of uncertainty, from primary frequency standards in the microwave domain to near infrared and visible domains, using frequency chains with {CO 2}/{OsO 4} as a transfer frequency standard. Preliminary estimates of the main effects which may shift the OsO 4 center line are reported.
Cohen, Benjamin Peter; Hooper, Rachel C.; Puetzer, Jennifer L.; Nordberg, Rachel; Asanbe, Ope; Hernandez, Karina A.; Spector, Jason A.
2016-01-01
Current techniques for autologous auricular reconstruction produce substandard ear morphologies with high levels of donor-site morbidity, whereas alloplastic implants demonstrate poor biocompatibility. Tissue engineering, in combination with noninvasive digital photogrammetry and computer-assisted design/computer-aided manufacturing technology, offers an alternative method of auricular reconstruction. Using this method, patient-specific ears composed of collagen scaffolds and auricular chondrocytes have generated auricular cartilage with great fidelity following 3 months of subcutaneous implantation, however, this short time frame may not portend long-term tissue stability. We hypothesized that constructs developed using this technique would undergo continued auricular cartilage maturation without degradation during long-term (6 month) implantation. Full-sized, juvenile human ear constructs were injection molded from high-density collagen hydrogels encapsulating juvenile bovine auricular chondrocytes and implanted subcutaneously on the backs of nude rats for 6 months. Upon explantation, constructs retained overall patient morphology and displayed no evidence of tissue necrosis. Limited contraction occurred in vivo, however, no significant change in size was observed beyond 1 month. Constructs at 6 months showed distinct auricular cartilage microstructure, featuring a self-assembled perichondrial layer, a proteoglycan-rich bulk, and rounded cellular lacunae. Verhoeff's staining also revealed a developing elastin network comparable to native tissue. Biochemical measurements for DNA, glycosaminoglycan, and hydroxyproline content and mechanical properties of aggregate modulus and hydraulic permeability showed engineered tissue to be similar to native cartilage at 6 months. Patient-specific auricular constructs demonstrated long-term stability and increased cartilage tissue development during extended implantation, and offer a potential tissue-engineered solution for the future of auricular reconstructions. PMID:26847742
[Study on mechanism of SOM stabilization of paddy soils under long-term fertilizations].
Luo, Lu; Zhou, Ping; Tong, Cheng-Li; Shi, Hui; Wu, Jin-Shui; Huang, Tie-Ping
2013-02-01
Fourier transform infrared spectroscopy (FTIR) was applied to study the structure of soil organic matter (SOM) of paddy soils under long-term different fertilization treatments. The aim was to clarify the different distribution of SOM between different fertilization methods and between topsoil and subsoil, and to explore the stability mechanism of SOM under different fertilization treatments. The results showed that the content of topsoil organic carbon (SOC) was the highest under organic-inorganic fertilizations, with the increment of SOC by 18.5%, 12.9% and 18.4% under high organic manure (HOM), low organic manure (LOM) and straw returning (STW) respectively compared with no fertilization treatment (CK). The long-term fertilizations also changed the chemical structure of SOM. As compared with CK, different fertilization treatments increased the functional group absorbing intensity of chemical resistance compounds (aliphatic, aromaticity), carbohydrate and organo-silicon compounds, which was the most distinctive under treatments of HOM, LOM and STW. For example, the absorbing intensity of alkyl was 0.30, 0.25 and 0.29 under HOM, LOM and STW, respectively. These values were increased by 87% , 56% and 81% as compared with that under CK treatment. The functional group absorbing intensity of SOM in the topsoil was stronger than that in the subsoil, with the most distinctive difference under HOM, LOM and STW treatments. The present research indicated that the enhanced chemical resistance of functional group of SOM may contribute to the high contents of SOC in the paddy soils under long-term organic-inorganic fertilizations, which also suggested a chemical stabilization mechanism of SOM in the paddy soils.
Lim, Sung A; Park, Yooyeon; Cheong, Yu Jin; Na, Kyung Sun; Joo, Choun-Ki
2016-04-01
High myopia is known to be a risk factor for long-term regression after laser refractive surgery. There have been few studies about the correction of moderate myopias that did not need retreatment after long-term follow-up. We evaluated 10 years of change in visual acuity and refractive power in eyes with moderate myopia after laser refractive surgery. We included patients that had undergone laser in situ keratomileusis (LASIK) or laser-assisted subepithelial keratectomy (LASEK) to correct their myopia and that had at least 10 years of follow-up. We evaluated the stability of visual acuity in terms of safety, efficacy, and refractive changes at examinations 6 months and 1, 2, 5, 7, and 10 years after surgery. The study evaluated 62 eyes (36 eyes in LASIK patients and 26 eyes in LASEK patients). In both groups, the efficacy index tended to decrease, and it was consistently higher in the LASEK group compared to the LASIK group over the 10 years of follow-up. The safety index improved over 10 years and was always higher than 0.9 in both groups. The difference between the spherical equivalent at 6 months postoperatively and later periods was statistically significant after 5, 7, and 10 years in both groups (LASIK, p = 0.036, p = 0.003, and p < 0.001, respectively; LASEK, p = 0.006, p = 0.002, and p = 0.001, respectively). Ten years after surgery,26 eyes (66.7%) in the LASIK group and 19 eyes (73.1%) in the LASEK group had myopia greater than 1 diopter. In comparison with the thickness at 6 months postoperatively, central corneal thickness was significantly increased after 5, 7, and 10 years in both LASIK and LASEK groups (LASIK, p < 0.001, p < 0.001, and p < 0.001, respectively; LASEK, p = 0.01, p < 0.001, and p < 0.001, respectively). Moderately myopic eyes showed progressive myopic shifting and corneal thickening after LASIK and LASEK during 10 years of follow-up. We also found that early refractive regression may indicate the long-term refractive outcome.
Lim, Sung A; Park, Yooyeon; Cheong, Yu Jin; Na, Kyung Sun
2016-01-01
Purpose High myopia is known to be a risk factor for long-term regression after laser refractive surgery. There have been few studies about the correction of moderate myopias that did not need retreatment after long-term follow-up. We evaluated 10 years of change in visual acuity and refractive power in eyes with moderate myopia after laser refractive surgery. Methods We included patients that had undergone laser in situ keratomileusis (LASIK) or laser-assisted subepithelial keratectomy (LASEK) to correct their myopia and that had at least 10 years of follow-up. We evaluated the stability of visual acuity in terms of safety, efficacy, and refractive changes at examinations 6 months and 1, 2, 5, 7, and 10 years after surgery. Results The study evaluated 62 eyes (36 eyes in LASIK patients and 26 eyes in LASEK patients). In both groups, the efficacy index tended to decrease, and it was consistently higher in the LASEK group compared to the LASIK group over the 10 years of follow-up. The safety index improved over 10 years and was always higher than 0.9 in both groups. The difference between the spherical equivalent at 6 months postoperatively and later periods was statistically significant after 5, 7, and 10 years in both groups (LASIK, p = 0.036, p = 0.003, and p < 0.001, respectively; LASEK, p = 0.006, p = 0.002, and p = 0.001, respectively). Ten years after surgery,26 eyes (66.7%) in the LASIK group and 19 eyes (73.1%) in the LASEK group had myopia greater than 1 diopter. In comparison with the thickness at 6 months postoperatively, central corneal thickness was significantly increased after 5, 7, and 10 years in both LASIK and LASEK groups (LASIK, p < 0.001, p < 0.001, and p < 0.001, respectively; LASEK, p = 0.01, p < 0.001, and p < 0.001, respectively). Conclusions Moderately myopic eyes showed progressive myopic shifting and corneal thickening after LASIK and LASEK during 10 years of follow-up. We also found that early refractive regression may indicate the long-term refractive outcome. PMID:27051256
Developments on a SEM-based X-ray tomography system: Stabilization scheme and performance evaluation
NASA Astrophysics Data System (ADS)
Gomes Perini, L. A.; Bleuet, P.; Filevich, J.; Parker, W.; Buijsse, B.; Kwakman, L. F. Tz.
2017-06-01
Recent improvements in a SEM-based X-ray tomography system are described. In this type of equipment, X-rays are generated through the interaction between a highly focused electron-beam and a geometrically confined anode target. Unwanted long-term drifts of the e-beam can lead to loss of X-ray flux or decrease of spatial resolution in images. To circumvent this issue, a closed-loop control using FFT-based image correlation is integrated to the acquisition routine, in order to provide an in-line drift correction. The X-ray detection system consists of a state-of-the-art scientific CMOS camera (indirect detection), featuring high quantum efficiency (˜60%) and low read-out noise (˜1.2 electrons). The system performance is evaluated in terms of resolution, detectability, and scanning times for applications covering three different scientific fields: microelectronics, technical textile, and material science.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-23
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0780] Bridging the Idea Development Evaluation Assessment and Long-Term Initiative and Total Product Life Cycle... Idea Development Evaluation Assessment and Long-Term Initiative and Total Product Life Cycle Approaches...
NASA Astrophysics Data System (ADS)
Kubota, T.; Aditian, A.
2014-12-01
Deriving the analysis of rainfall data in various mountainous locations, increase in rainfall that is deemed to be induced by the global climate change is obvious in Kyushu district, western Japan. On this point of view, its long term impact on the forest slope stability is analyzed with field investigation and numerical simulation such as finite element method (FEM). On the other hand, the influence of earthquake such as cracks on the slope due to seismic vibration was also analyzed with FEM. In this case, the slope stability analysis to obtain the factor of safety "Fs" is conducted. Here, in case of the Fs > 1.0, the slope is stable. In addition, the slope stabilizing effect of the forest mainly due to the roots strength is evaluated on some unstable slopes. Simultaneously, a holistic estimation over landslide groups is conducted by comparing "Fs" on forest slopes with non- forest slopes. Therefore, the following conclusions are obtained: 1) Comparing the Fs without increased rainfall from the previous decade and the one with actual rainfall, the former case is 1.04 ~1.06 times more stable than the latter. 2) On the other hand, the forest slopes are estimated to be up to approximately 1.5 to 2.5 times more stable than the slope without forest. Therefore, the slope stabilizing effect by the forest is much higher than the increasing rainfall influence i.e. the climate change effect. These results imply that an appropriate forest existence is important under the climate change condition to prevent forest slope degradation. 3) Comparing with the destabilization of the slope by seismic activities (vibration) due to the reduction of soil strength and "cracks = slope deformation" (8~9 % to 30% reduction in Fs even after an earthquake of 490gal), the influence of the long term rainfall increase on slopes (such as 1% decrease in Fs) is relatively small in the study area.
Hasiuk, Michelle M M; Drygas, Kevin A; Lewis, Daniel D
2017-11-01
Two dogs with spontaneous luxation of the long digital extensor tendon of origin were managed by performing a sulcoplasty and applying a plate bridging the extensor sulcus. Lameness resolved and neither dog had recurrence of lameness 59 and 15 months following surgery.
McLaren, Edward A
2013-09-01
As the economy has receded in recent years, many patients have been inclined to reject dental treatment beyond what they feel is the minimal amount necessary. Increasingly, there has been reluctance to take on the expense of full-mouth restorations and time-consuming procedures. Consequently, clinicians can benefit from innovative, conservative, interim solutions that enable them to provide segment treatment with long-term stability and esthetics, with lower initial cost. The bonded functional esthetic prototype (BFEP) allows fabrication of up to 14 teeth from composite in 1 hour, providing either a pre-treatment restoration or a long-term provisional solution until further treatment can be completed. As demonstrated herein, the BFEP enables superb function, stability, and esthetics in the interim while dispersing the cost of definitive treatment over time.
Long-term physical and oxidative stability of liposomes containing glycerides of lipoic acid
USDA-ARS?s Scientific Manuscript database
The acyl glycerides of lipoic and dihydrolipoic acids may serve as slow-release sources for cutaneous delivery of these antioxidants when formulated in a liposomal vehicle. Accelerated storage testing was conducted to determine the storage stability of the lipoic derivatives and of the soybean phosp...
USDA-ARS?s Scientific Manuscript database
Arid land cryptobiotic soil crusts govern water infiltration, soil aggregate stability and nutrient cycling between soil microbial communities and vascular plants. Surface mining involves removal of topsoil and associated crust and storage in mixed mounds for extended periods. The exposed subsoil an...
Concurrent and Long-Term Impact of Intimate Partner Violence on Employment Stability
ERIC Educational Resources Information Center
Crowne, Sarah Shea; Juon, Hee-Soon; Ensminger, Margaret; Burrell, Lori; McFarlane, Elizabeth; Duggan, Anne
2011-01-01
Previous research suggests that experiencing intimate partner violence (IPV) may negatively affect employment outcomes. This study explores the relationship between IPV and employment stability both concurrently and longitudinally among a sample of 512 predominantly Asian American and Pacific Islander young women living in Hawaii. Women in this…
Stability of Behavioral Ratings of Children with SLI.
ERIC Educational Resources Information Center
Redmond, Sean M.; Rice, Mabel L.
2002-01-01
A study investigated the long-term stability of the teacher and parent behavioral ratings of 37 children with specific language impairment. Results indicate diminishment in teacher-reported behavior problems in most areas of socioemotional development from kindergarten to second grade and increasing congruence between teacher and parent ratings.…
Nagai, Shuko; Yonemoto, Naohiro; Rabesandratana, Norotiana; Andrianarimanana, Diavolana; Nakayama, Takeo; Mori, Rintaro
2011-12-01
To examine the long-term effects of earlier initiated continuous Kangaroo Mother Care (KMC) for relatively stable low-birth-weight (LBW) infants in a resource-limited country. A randomized controlled trial with long-term follow-up was performed in LBW infants in Madagascar. Earlier continuous KMC (intervention group) was initiated as soon as possible within 24 h postbirth, and later continuous KMC (control group: conventional care) was initiated after complete stabilization. Outcome measures were mortality or readmission, nutritional indicators at 6-12 months postbirth and feeding condition at 6 months postbirth (ClinicalTrials.gov, NCT00531492). A total of 72 infants were followed for mortality or readmission at 6-12 months postbirth. There was no difference between the two groups (7/36 vs. 7/36, Risk ratio (RR), 1.00; 95% CIs, 0.39-2.56; p = 1.00). The proportion of exclusive breast feeding (EBF) at 6 months postbirth was significantly higher with earlier KMC than later KMC (12/29 vs. 4/26; RR 2.69; 95% CIs, 1.00-7.31; p = 0.04). There were no differences in nutritional indicators between the two groups at 6-12 months postbirth. Earlier initiated continuous KMC results in a significantly higher proportion of EBF at 6 months postbirth. Further larger-scale long-term evaluations of earlier initiated continuous KMC for LBW infants are needed. © 2011 The Author(s)/Acta Paediatrica © 2011 Foundation Acta Paediatrica.
ERIC Educational Resources Information Center
Dorrepaal, Ethy; Thomaes, Kathleen; Smit, Johannes H.; van Balkom, Anton J. L. M.; van Dyck, Richard; Veltman, Dick J.; Draijer, Nel
2010-01-01
Objective: This study tests a Stabilizing Group Treatment protocol, designed for the management of the long-term sequelae of child abuse, that is, Complex Posttraumatic Stress Disorder (Complex PTSD). Evidence-based treatment for this subgroup of PTSD patients is largely lacking. This stabilizing treatment aims at improving Complex PTSD using…
Effects of Bedrock Landsliding on Cosmogenically Determined Erosion Rates
NASA Technical Reports Server (NTRS)
Niemi, Nathan; Oskin, Mike; Burbank, Douglas; Heimsath, Arjun
2005-01-01
The successful quantification of long-term erosion rates underpins our understanding of landscape. formation, the topographic evolution of mountain ranges, and the mass balance within active orogens. The measurement of in situ-produced cosmogenic radionuclides (CRNs) in fluvial and alluvial sediments is perhaps the method with the greatest ability to provide such long-term erosion rates. In active orogens, however, deep-seated bedrock landsliding is an important erosional process, the effect of which on CRN-derived erosion rates is largely unquantified. We present a numerical simulation of cosmogenic nuclide production and distribution in landslide-dominated catchments to address the effect of bedrock landsliding on cosmogenic erosion rates in actively eroding landscapes. Results of the simulation indicate that the temporal stability of erosion rates determined from CRN concentrations in sediment decreases with increased ratios of landsliding to sediment detachment rates within a given catchment area, and that larger catchment areas must be sampled with increased frequency of landsliding in order to accurately evaluate long-term erosion rates. In addition, results of this simulation suggest that sediment sampling for CRNs is the appropriate method for determining long-term erosion rates in regions dominated by mass-wasting processes, while bedrock surface sampling for CRNs is generally an ineffective means of determining long-term erosion rates. Response times of CRN concentrations to changes in erosion rate indicate that climatically driven cycles of erosion may be detected relatively quickly after such changes occur, but that complete equilibration of CRN concentrations to new erosional conditions may take tens of thousands of years. Simulation results of CRN erosion rates are compared with a new, rich dataset of CRN concentrations from the Nepalese Himalaya, supporting conclusions drawn from the simulation.
NASA Astrophysics Data System (ADS)
Zhang, Shulan; Wang, Renjie; Yang, Xueyun; Sun, Benhua; Li, Qinghui
2016-12-01
Soil aggregation was studied in a 21-year experiment conducted on an Anthrosol. The soil management regimes consisted of cropland abandonment, bare fallow without vegetation and cropping system. The cropping system was combined with the following nutrient management treatments: control (CONTROL, no nutrient input); nitrogen, phosphorus and potassium (NPK); straw plus NPK (SNPK); and manure (M) plus NPK (MNPK). Compared with the CONTROL treatment, the abandonment treatment significantly increased the formation of large soil macroaggregates (>2 mm) and consequently improved the stability of aggregates in the surface soil layer due to enhancement of hyphal length and of soil organic matter content. However, in response to long-term bare fallow treatment aggregate stability was low, as were the levels of aggregating agents. Long term fertilization significantly redistributed macroaggregates; this could be mainly ascribed to soil organic matter contributing to the formation of 0.5-2 mm classes of aggregates and a decrease in the formation of the >2 mm class of aggregates, especially in the MNPK treatment. Overall, hyphae represented a major aggregating agent in both of the systems tested, while soil organic compounds played significantly different roles in stabilizing aggregates in Anthrosol when the cropping system and the soil management regimes were compared.
Zhang, Shulan; Wang, Renjie; Yang, Xueyun; Sun, Benhua; Li, Qinghui
2016-01-01
Soil aggregation was studied in a 21-year experiment conducted on an Anthrosol. The soil management regimes consisted of cropland abandonment, bare fallow without vegetation and cropping system. The cropping system was combined with the following nutrient management treatments: control (CONTROL, no nutrient input); nitrogen, phosphorus and potassium (NPK); straw plus NPK (SNPK); and manure (M) plus NPK (MNPK). Compared with the CONTROL treatment, the abandonment treatment significantly increased the formation of large soil macroaggregates (>2 mm) and consequently improved the stability of aggregates in the surface soil layer due to enhancement of hyphal length and of soil organic matter content. However, in response to long-term bare fallow treatment aggregate stability was low, as were the levels of aggregating agents. Long term fertilization significantly redistributed macroaggregates; this could be mainly ascribed to soil organic matter contributing to the formation of 0.5–2 mm classes of aggregates and a decrease in the formation of the >2 mm class of aggregates, especially in the MNPK treatment. Overall, hyphae represented a major aggregating agent in both of the systems tested, while soil organic compounds played significantly different roles in stabilizing aggregates in Anthrosol when the cropping system and the soil management regimes were compared. PMID:27958366
Hadrup, Sine Reker; Maurer, Dominik; Laske, Karoline; Frøsig, Thomas Mørch; Andersen, Sofie Ramskov; Britten, Cedrik M; van der Burg, Sjoerd H; Walter, Steffen; Gouttefangeas, Cécile
2015-01-01
Fluorescence-labeled peptide-MHC class I multimers serve as ideal tools for the detection of antigen-specific T cells by flow cytometry, enabling functional and phenotypical characterization of specific T cells at the single cell level. While this technique offers a number of unique advantages, MHC multimer reagents can be difficult to handle in terms of stability and quality assurance. The stability of a given fluorescence-labeled MHC multimer complex depends on both the stability of the peptide-MHC complex itself and the stability of the fluorochrome. Consequently, stability is difficult to predict and long-term storage is generally not recommended. We investigated here the possibility of cryopreserving MHC multimers, both in-house produced and commercially available, using a wide range of peptide-MHC class I multimers comprising virus and cancer-associated epitopes of different affinities presented by various HLA-class I molecules. Cryopreservation of MHC multimers was feasible for at least 6 months, when they were dissolved in buffer containing 5-16% glycerol (v/v) and 0.5% serum albumin (w/v). The addition of cryoprotectants was tolerated across three different T-cell staining protocols for all fluorescence labels tested (PE, APC, PE-Cy7 and Quantum dots). We propose cryopreservation as an easily implementable method for stable storage of MHC multimers and recommend the use of cryopreservation in long-term immunomonitoring projects, thereby eliminating the variability introduced by different batches and inconsistent stability. © 2014 International Society for Advancement of Cytometry.
Hadrup, Sine Reker; Maurer, Dominik; Laske, Karoline; Frøsig, Thomas Mørch; Andersen, Sofie Ramskov; Britten, Cedrik M; van der Burg, Sjoerd H; Walter, Steffen; Gouttefangeas, Cécile
2015-01-01
Fluorescence-labeled peptide-MHC class I multimers serve as ideal tools for the detection of antigen-specific T cells by flow cytometry, enabling functional and phenotypical characterization of specific T cells at the single cell level. While this technique offers a number of unique advantages, MHC multimer reagents can be difficult to handle in terms of stability and quality assurance. The stability of a given fluorescence-labeled MHC multimer complex depends on both the stability of the peptide-MHC complex itself and the stability of the fluorochrome. Consequently, stability is difficult to predict and long-term storage is generally not recommended. We investigated here the possibility of cryopreserving MHC multimers, both in-house produced and commercially available, using a wide range of peptide-MHC class I multimers comprising virus and cancer-associated epitopes of different affinities presented by various HLA-class I molecules. Cryopreservation of MHC multimers was feasible for at least 6 months, when they were dissolved in buffer containing 5–16% glycerol (v/v) and 0.5% serum albumin (w/v). The addition of cryoprotectants was tolerated across three different T-cell staining protocols for all fluorescence labels tested (PE, APC, PE-Cy7 and Quantum dots). We propose cryopreservation as an easily implementable method for stable storage of MHC multimers and recommend the use of cryopreservation in long-term immunomonitoring projects, thereby eliminating the variability introduced by different batches and inconsistent stability. © 2014 International Society for Advancement of Cytometry PMID:25297339
Study of advanced fuel system concepts for commercial aircraft and engines
NASA Technical Reports Server (NTRS)
Versaw, E. F.; Brewer, G. D.; Byers, W. D.; Fogg, H. W.; Hanks, D. E.; Chirivella, J.
1983-01-01
The impact on a commercial transport aircraft of using fuels which have relaxed property limits relative to current commercial jet fuel was assessed. The methodology of the study is outlined, fuel properties are discussed, and the effect of the relaxation of fuel properties analyzed. Advanced fuel system component designs that permit the satisfactory use of fuel with the candidate relaxed properties in the subject aircraft are described. The two fuel properties considered in detail are freezing point and thermal stability. Three candidate fuel system concepts were selected and evaluated in terms of performance, cost, weight, safety, and maintainability. A fuel system that incorporates insulation and electrical heating elements on fuel tank lower surfaces was found to be most cost effective for the long term.
Hashimoto, Tadafumi; Osawa, Yusuke; Itoh, Shinsuke; Mochizuki, Masahito; Nishimoto, Kazutoshi
2013-06-01
To prevent primary water stress corrosion cracking (PWSCC), water jet peening (WJP) has been used on the welds of Ni-based alloys in pressurized water reactors (PWRs). Before WJP, the welds are machined and buffed in order to conduct a penetrant test (PT) to verify the weld qualities to access, and microstructure evolution takes place in the target area due to the severe plastic deformation. The compressive residual stresses induced by WJP might be unstable under elevated temperatures because of the high dislocation density in the compressive stress layer. Therefore, the stability of the compressive residual stresses caused by WJP was investigated during long-term operation by considering the microstructure evolution due to the working processes. The following conclusions were made: The compressive residual stresses were slightly relaxed in the surface layers of the thermally aged specimens. There were no differences in the magnitude of the relaxation based on temperature or time. The compressive residual stresses induced by WJP were confirmed to remain stable under elevated temperatures. The stress relaxation at the surface followed the Johnson-Mehl equation, which states that stress relaxation can occur due to the recovery of severe plastic strain, since the estimated activation energy agrees very well with the self-diffusion energy for Ni. By utilizing the additivity rule, it was indicated that stress relaxation due to recovery is completed during the startup process. It was proposed that the long-term stability of WJP under elevated temperatures must be assessed based on compressive stresses with respect to the yield stress. Thermal elastic-plastic creep analysis was performed to predict the effect of creep strain. After 100 yr of simulated continuous operation at 80% capacity, there was little change in the WJP compressive stresses under an actual operating temperature of 623 K. Therefore, the long-term stability of WJP during actual operation was analytically predicted.
Long-term stability measurements of low concentration Volatile Organic Compound gas mixtures
NASA Astrophysics Data System (ADS)
Allen, Nick; Amico di Meane, Elena; Brewer, Paul; Ferracci, Valerio; Corbel, Marivon; Worton, David
2017-04-01
VOCs (Volatile Organic Compounds) are a class of compounds with significant influence on the atmosphere due to their large anthropogenic and biogenic emission sources. VOC emissions have a significant impact on the atmospheric hydroxyl budget and nitrogen reservoir species, while also contributing indirectly to the production of tropospheric ozone and secondary organic aerosol. However, the global budget of many of these species are poorly constrained. Moreover, the World Meteorological Organization's (WMO) Global Atmosphere Watch (GAW) have set challenging data quality objectives for atmospheric monitoring programmes for these classes of traceable VOCs, despite the lack of available stable gas standards. The Key-VOCs Joint Research Project is an ongoing three-year collaboration with the aim of improving the measurement infrastructure of important atmospheric VOCs by providing traceable and comparable reference gas standards and by validating new measurement systems in support of the air monitoring networks. It focuses on VOC compounds that are regulated by European legislation, that are relevant for indoor air monitoring and for air quality and climate monitoring programmes like the VOC programme established by the WMO GAW and the European Monitoring and Evaluation Programme (EMEP). These VOCs include formaldehyde, oxy[genated]-VOCs (acetone, ethanol and methanol) and terpenes (a-pinene, 1,8-cineole, δ-3-carene and R-limonene). Here we present the results of a novel long term stability study for low concentration formaldehyde, oxy-VOC and terpenes gas mixtures produced by the Key-VOCs consortium with discussion regarding the implementation of improved preparation techniques and the use of novel cylinder passivation chemistries to guarantee mixture stability.
The Evaluation of the National Long Term Care Demonstration: Final Report. Executive Summary.
ERIC Educational Resources Information Center
Mathematica Policy Research, Inc., Plainsboro, NJ.
This report describes the evaluation of the National Long-Term Care (Channeling) Demonstration, a rigorous test of comprehensive case management of community care as a way of containing long-term care costs for the impaired elderly while providing adequate care to those in need. The evaluation process is presented as an experimental design with…
Cížek, Martin; Hucl, Václav; Hrabina, Jan; Smíd, Radek; Mikel, Břetislav; Lazar, Josef; Cíp, Ondřej
2014-01-20
A passive optical resonator is a special sensor used for measurement of lengths on the nanometer and sub-nanometer scale. A stabilized optical frequency comb can provide an ultimate reference for measuring the wavelength of a tunable laser locked to the optical resonator. If we lock the repetition and offset frequencies of the comb to a high-grade radiofrequency (RF) oscillator its relative frequency stability is transferred from the RF to the optical frequency domain. Experiments in the field of precise length metrology of low-expansion materials are usually of long-term nature so it is required that the optical frequency comb stay in operation for an extended period of time. The optoelectronic closed-loop systems used for stabilization of combs are usually based on traditional analog electronic circuits processing signals from photodetectors. From an experimental point of view, these setups are very complicated and sensitive to ambient conditions, especially in the optical part, therefore maintaining long-time operation is not easy. The research presented in this paper deals with a novel approach based on digital signal processing and a software-defined radio. We describe digital signal processing algorithms intended for keeping the femtosecond optical comb in a long-time stable operation. This need arose during specialized experiments involving measurements of optical frequencies of tunable continuous-wave lasers. The resulting system is capable of keeping the comb in lock for an extensive period of time (8 days or more) with the relative stability better than 1.6 × 10(-11).
Li, Juan; Suo, Jinping; Zou, Peng; Jia, Lintao; Wang, Shifang
2010-01-01
The data for long-term drug-delivery systems are scarce compared to the short-term systems because the required research efforts are more time-consuming. In this study, we report a novel cross-linked composite based on poly(vinyl alcohol) (PVA) containing cupric ions for long-term delivery, which is helpful for contraception and trace element balance in the human body. The composition, corrosion products, crystal structure, chemical structure and mechanical stability of the composite, after being immersed in simulated body fluid (SBF) for one year, were studied by X-ray fluorescence spectroscopy (XRF), X-ray diffraction (XRD), differential scanning calorimetry (DSC), Fourier-transform infrared spectroscopy (FT-IR) and mechanical testing. The results show that no other new elements, such as P, Cl and Ca, appear on the surface of the composite and no Cu(2)O was formed after immersion in SBF for one year. The effectiveness of copper can be greatly improved and the side-effects caused by these compounds might also be eliminated. Furthermore, this novel composite exhibits long-term mechanical stability in SBF. The present in vitro long-term data suggest that this novel copper-containing composite may serve as a substitute for conventional materials of copper-containing intrauterine devices (Cu-IUDs) and as a carrier for controlled-release material in a variety of other applications.
NASA Astrophysics Data System (ADS)
Ochs, Oliver; Heckl, Wolfgang M.; Lackinger, Markus
2018-05-01
Fundamental insights into the kinetics and thermodynamics of supramolecular self-assembly on surfaces are uniquely gained by variable-temperature high-resolution Scanning-Tunneling-Microscopy (STM). Conventionally, these experiments are performed with standard ambient microscopes extended with heatable sample stages for local heating. However, unavoidable solvent evaporation sets a technical limit on the duration of these experiments, hence prohibiting long-term experiments. These, however, would be highly desirable to provide enough time for temperature stabilization and settling of drift but also to study processes with inherently slow kinetics. To overcome this dilemma, we propose a STM that can operate fully immersed in solution. The instrument is mounted onto the lid of a hermetically sealed heatable container that is filled with the respective solution. By closing the container, both the sample and microscope are immersed in solution. Thereby solvent evaporation is eliminated and an environment for long-term experiments with utmost stable and controllable temperatures between room-temperature and 100 °C is provided. Important experimental requirements for the immersion-STM and resulting design criteria are discussed, the strategy for protection against corrosive media is described, the temperature stability and drift behavior are thoroughly characterized, and first long-term high resolution experiments at liquid-solid interfaces are presented.
Venkatesan, Shanmuganathan; Surya Darlim, Elmer; Tsai, Ming-Hsiang; Teng, Hsisheng; Lee, Yuh-Lang
2018-04-04
A graphene oxide sponge (GOS) is utilized for the first time as a nanofiller (NF) in printable electrolytes (PEs) based on poly(ethylene oxide) and poly(vinylidene fluoride) for quasi-solid-state dye-sensitized solar cells (QS-DSSCs). The effects of the various concentrations of GOS NFs on the ion diffusivity and conductivity of electrolytes and the performance of the QS-DSSCs are studied. The results show that the presence of GOS NFs significantly increases the diffusivity and conductivity of the PEs. The introduction of 1.5 wt % of GOS NFs decreases the charge-transfer resistance at the Pt-counter electrode/electrolyte interface ( R pt ) and increases the recombination resistance at the photoelectrode/electrolyte interface ( R ct ). QS-DSSC utilizing 1.5 wt % GOS NFs can achieve an energy conversion efficiency (8.78%) higher than that found for their liquid counterpart and other reported polymer gel electrolytes/GO NFs based DSSCs. The high energy conversion efficiency is a consequence of the increase in both the open-circuit potential ( V oc ) and fill factor with a slight decrease in current density ( J sc ). The cell efficiency can retain 86% of its initial value after a 500 h stability test at 60 °C under dark conditions. The long-term stability of the QS-DSSC with GOS NFs is higher than that without NFs. This result indicates that the GOS NFs do not cause dye-desorption from the photoanode in a long-term stability test, which infers a superior performance of GOS NFs as compared to TiO 2 NFs in terms of increasing the efficiency and long-term stability of QS-DSSCs.
CAN STABILITY REALLY PREDICT AN IMPENDING SLIP-RELATED FALL AMONG OLDER ADULTS?
Yang, Feng; Pai, Yi-Chung
2015-01-01
The primary purpose of this study was to systematically evaluate and compare the predictive power of falls for a battery of stability indices, obtained during normal walking among community-dwelling older adults. One hundred and eighty seven community-dwelling older adults participated in the study. After walking regularly for 20 strides on a walkway, participants were subjected to an unannounced slip during gait under the protection of a safety harness. Full body kinematics and kinetics were monitored during walking using a motion capture system synchronized with force plates. Stability variables, including feasible-stability-region measurement, margin of stability, the maximum Floquet multiplier, the Lyapunov exponents (short- and long-term), and the variability of gait parameters (including the step length, step width, and step time) were calculated for each subject. Accuracy of predicting slip outcome (fall vs. recovery) was examined for each stability variable using logistic regression. Results showed that the feasible-stability-region measurement predicted fall incidence among these subjects with the highest accuracy (68.4%). Except for the step width (with an accuracy of 60.2%), no other stability variables could differentiate fallers from those who did not fall for the sample studied in this study. The findings from the present study could provide guidance to identify individuals at increased risk of falling using the feasible-stability-region measurement or variability of the step width. PMID:25458148
Winfield, Jonathan; Chambers, Lily D; Rossiter, Jonathan; Ieropoulos, Ioannis
2013-11-01
The long and short-term stability of two porous dependent ion exchange materials; starch-based compostable bags (BioBag) and ceramic, were compared to commercially available cation exchange membrane (CEM) in microbial fuel cells. Using bi-directional polarisation methods, CEM exhibited power overshoot during the forward sweep followed by significant power decline over the reverse sweep (38%). The porous membranes displayed no power overshoot with comparably smaller drops in power during the reverse sweep (ceramic 8%, BioBag 5.5%). The total internal resistance at maximum power increased by 64% for CEM compared to 4% (ceramic) and 6% (BioBag). Under fixed external resistive loads, CEM exhibited steeper pH reductions than the porous membranes. Despite its limited lifetime, the BioBag proved an efficient material for a stable microbial environment until failing after 8 months, due to natural degradation. These findings highlight porous separators as ideal candidates for advancing MFC technology in terms of cost and operation stability. Copyright © 2013 Elsevier Ltd. All rights reserved.
Yu, Xinzhi; Lu, Bingan; Xu, Zhi
2014-02-01
Nanohoneycomb-like strongly coupled CoMoO4 -3D graphene hybird electrodes are synthesized for supercapacitors which exhibit excellent specific capacitance and superior long-term cycle stability. The supercapacitor device can power a 5 mm-diameter LED efficiently for more than 3 min with a charging time of only 2 s, and shows high energy densities and good cycle stability. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Debey-Pascher, Svenja; Hofmann, Andrea; Kreusch, Fatima; Schuler, Gerold; Schuler-Thurner, Beatrice; Schultze, Joachim L.; Staratschek-Jox, Andrea
2011-01-01
Microarray-based transcriptome analysis of peripheral blood as surrogate tissue has become an important approach in clinical implementations. However, application of gene expression profiling in routine clinical settings requires careful consideration of the influence of sample handling and RNA isolation methods on gene expression profile outcome. We evaluated the effect of different sample preservation strategies (eg, cryopreservation of peripheral blood mononuclear cells or freezing of PAXgene-stabilized whole blood samples) on gene expression profiles. Expression profiles obtained from cryopreserved peripheral blood mononuclear cells differed substantially from those of their nonfrozen counterpart samples. Furthermore, expression profiles in cryopreserved peripheral blood mononuclear cell samples were found to undergo significant alterations with increasing storage period, whereas long-term freezing of PAXgene RNA stabilized whole blood samples did not significantly affect stability of gene expression profiles. This report describes important technical aspects contributing toward the establishment of robust and reliable guidance for gene expression studies using peripheral blood and provides a promising strategy for reliable implementation in routine handling for diagnostic purposes. PMID:21704280
Influence of hydrophilic surfactants on the properties of multiple W/O/W emulsions.
Schmidts, T; Dobler, D; Nissing, C; Runkel, F
2009-10-01
Multiple W/O/W emulsions for topical application using Span 80 as a lipophilic emulsifier were prepared. Several hydrophilic emulsifiers were tested in respect of their suitability for the preparation of multiple emulsions. In addition, the effect of different oil-phase compositions on emulsion stability was investigated. The physicochemical parameters of the formulations were characterized and their long-term stability was evaluated by means of rheological measurements, droplet size observations and conductivity analysis. As discovered, the modification of an oil-phase composition results in a decrease in the diffusion coefficient of water and water-soluble substances and, consequently, in enhanced stability. The influence of the release of electrolytes from the inner to the outer water phase on the emulsion stability behaviour was investigated. It was found, that the effect of the hydrophilic emulsifiers on the formulation properties is related not only to its HLB value, but rather to its chemical composition. As a result, polyethoxylated ethers of fatty alcohols (C=16-18) with HLBs between 15.3 and 16.2 appear to be the most suitable ones for creating stable formulations.
Kinematic variability, fractal dynamics and local dynamic stability of treadmill walking
2011-01-01
Background Motorized treadmills are widely used in research or in clinical therapy. Small kinematics, kinetics and energetics changes induced by Treadmill Walking (TW) as compared to Overground Walking (OW) have been reported in literature. The purpose of the present study was to characterize the differences between OW and TW in terms of stride-to-stride variability. Classical (Standard Deviation, SD) and non-linear (fractal dynamics, local dynamic stability) methods were used. In addition, the correlations between the different variability indexes were analyzed. Methods Twenty healthy subjects performed 10 min TW and OW in a random sequence. A triaxial accelerometer recorded trunk accelerations. Kinematic variability was computed as the average SD (MeanSD) of acceleration patterns among standardized strides. Fractal dynamics (scaling exponent α) was assessed by Detrended Fluctuation Analysis (DFA) of stride intervals. Short-term and long-term dynamic stability were estimated by computing the maximal Lyapunov exponents of acceleration signals. Results TW did not modify kinematic gait variability as compared to OW (multivariate T2, p = 0.87). Conversely, TW significantly modified fractal dynamics (t-test, p = 0.01), and both short and long term local dynamic stability (T2 p = 0.0002). No relationship was observed between variability indexes with the exception of significant negative correlation between MeanSD and dynamic stability in TW (3 × 6 canonical correlation, r = 0.94). Conclusions Treadmill induced a less correlated pattern in the stride intervals and increased gait stability, but did not modify kinematic variability in healthy subjects. This could be due to changes in perceptual information induced by treadmill walking that would affect locomotor control of the gait and hence specifically alter non-linear dependencies among consecutive strides. Consequently, the type of walking (i.e. treadmill or overground) is important to consider in each protocol design. PMID:21345241
Application of 2-Aminothiazoline-4-carboxylic Acid as a Forensic Marker of Cyanide Exposure.
Rużycka, Monika; Giebułtowicz, Joanna; Fudalej, Marcin; Krajewski, Paweł; Wroczyński, Piotr
2017-02-20
Cyanides are infamous for their highly poisonous properties. Accidental cyanide poisoning occurs frequently, but occasionally, intentional poisonings also occur. Inhalation of fumes generated by fire may also cause cyanide poisoning. There are many limitations in direct analysis of cyanide. 2-Aminothiazoline-4-carboxylic acid (ATCA), a cyanide metabolite, seems to be the only surrogate that is being used in the detection of cyanide because of its stability and its cyanide-dependent quality in a biological matrix. Unfortunately, toxicokinetic studies on diverse animal models suggest significant interspecies differences; therefore, the attempt to extrapolate animal models to human models may be unsuccessful. The aim of the present study was to evaluate the use of ATCA as a forensic marker of cyanide exposure. For this purpose, post-mortem materials (blood and organs) from fire victims (n = 32) and cyanide-poisoned persons (n = 3) were collected. The distribution of ATCA in organs and its thermal stability were evaluated. The variability of cyanides in a putrid sample and in the context of their long-term and higher temperature stability was established. The presence of ATCA was detected by using an LC-MS/MS method and that of cyanide was detected spectrofluorimetrically. This is the first report on the endogenous ATCA concentrations and the determination of ATCA distribution in tissues of fire victims and cyanide-poisoned persons. It was found that blood and heart had the highest ATCA concentrations. ATCA was observed to be thermally stable even at 90 °C. Even though the cyanide concentration was not elevated in putrid samples, it was unstable during long-term storage and at higher temperature, as expected. The relationship between ATCA and cyanides was also observed. Higher ATCA concentrations were related to increased levels of cyanide in blood and organs (less prominent). ATCA seems to be a reliable forensic marker of exposure to lethal doses of cyanide.
Percutaneous Permeation of Topical Phtalocyanine Studied by Photoacoustic Measurements
NASA Astrophysics Data System (ADS)
Silva, E. P. O.; Beltrame, M.; Cardoso, L. E.; Barja, P. R.
2012-11-01
The purpose of this study was to evaluate the percutaneous permeation of topical hydroxy-(29 H,31 H-phthalocyaninato)aluminum (PcAlOH) on pig ear skin employing photoacoustic (PA) measurements. The PcAlOH was incorporated in an emulsion with assessed stability parameters of pH and short- and long-term stability tests. Pig skin was prepared through a heat separation technique, and the outer skin of the cartilage was removed with a scalpel. Skin samples were then cut and treated with sodium bromide 2 mol . L-1 for 6 h at 37 °C. The epidermis layer was washed with purified water, dried, and stored under reduced pressure until use. The skin permeation kinetics were determined by PA measurements as a function of time, performed with an open PA cell developed at Universidade do Vale do Paraíba. Short- and long-term stability tests showed no phase separation. A significant difference was found between the typical times for percutaneous permeation of the emulsion base and the emulsion + PcAlOH. The study showed two absorption transients due to the physical diffusion of molecules in the skin sample. The first is attributed to the penetration of molecules that promptly passed through the lipid barrier, while the second is related to the molecules that had greater difficulty of passing through. This slower component in the absorption curves is attributed to the penetration of PcAlOH, a planar molecule whose percutaneous penetration is more difficult. The study indicates that the formulations containing PcAlOH have stable characteristics and show promising results in absorption into the skin. The presence of the photosensitive agent in the formulation contributed significantly to the larger time constant observed. PA measurements allowed the evaluation of the penetration kinetics of PcAlOH in pig ear skin; the methodology employed may be used in the determination of the percutaneous permeation of phthalocyanines in further studies.
Larrosa, Pablo Nicolás Fernández; Ojea, Alejandro; Ojea, Ignacio; Molina, Victor Alejandro; Zorrilla-Zubilete, María Aurelia; Delorenzi, Alejandro
2017-07-01
Acute stress impairs memory retrieval of several types of memories. An increase in glucocorticoids, several minutes after stressful events, is described as essential to the impairing retrieval-effects of stressors. Moreover, memory retrieval under stress can have long-term consequences. Through what process does the reactivated memory under stress, despite the disrupting retrieval effects, modify long-term memories? The reconsolidation hypothesis proposes that a previously consolidated memory reactivated by a reminder enters a vulnerability phase (labilization) during which it is transiently sensitive to modulation, followed by a re-stabilization phase. However, previous studies show that the expression of memories during reminder sessions is not a condition to trigger the reconsolidation process since unexpressed memories can be reactivated and labilized. Here we evaluate whether it is possible to reactivate-labilize a memory under the impairing-effects of a mild stressor. We used a paradigm of human declarative memory whose reminder structure allows us to differentiate between a reactivated-labile memory state and a reactivated but non-labile state. Subjects memorized a list of five cue-syllables associated with their respective response-syllables. Seventy-two hours later, results showed that the retrieval of the paired-associate memory was impaired when tested 20min after a mild stressor (cold pressor stress (CPS)) administration, coincident with cortisol levels increase. Then, we investigated the long-term effects of CPS administration prior to the reminder session. Under conditions where the reminder initiates the reconsolidation process, CPS impaired the long-term memory expression tested 24h later. In contrast, CPS did not show effects when administered before a reminder session that does not trigger reconsolidation. Results showed that memory reactivation-labilization occurs even when retrieval was impaired. Memory reactivation under stress could hinder -via reconsolidation- the probability of the traces to be expressed in the long term. Copyright © 2017 Elsevier Inc. All rights reserved.
Delgado, Candida; Gonzalez-Gordon, Rodrigo G.; Aragón, Estívaliz; Navarro, Jose I.
2017-01-01
The aim of this study was to compare the advantages and disadvantages of different behavioral assessment procedures with the purpose of design a long-term assessment procedure that brings together the benefits observed. The study involved four adults with severe and profound intellectual disabilities and severe behavioral problems. A behavioral assessment has been carried out with Scatter Plot, Antecedent-Behavior-Consequence record sheets and, finally, The Observer XT. We conducted a comprehensive assessment of challenging behavior of each participant, by reviewing bio-psychosocial records, interviewing family and direct caregiver staff, as well as direct observation. A large inter-subject behavior variability and instability of intra-subject behavior were found, raising questions about the election of the period to evaluate. The first evaluation level highlighted information about stability of behavior, the second level stand out the context in which it occurs and the third level detailed the different topographies of each behavioral category. The results suggest the desirability of a continuous assessment by combining these three levels for adjusting to the specific characteristics of behavior. We suggest the need of designing a single behavioral assessment procedure that includes the benefits observed in each of the instruments used. PMID:28154543
Delgado, Candida; Gonzalez-Gordon, Rodrigo G; Aragón, Estívaliz; Navarro, Jose I
2017-01-01
The aim of this study was to compare the advantages and disadvantages of different behavioral assessment procedures with the purpose of design a long-term assessment procedure that brings together the benefits observed. The study involved four adults with severe and profound intellectual disabilities and severe behavioral problems. A behavioral assessment has been carried out with Scatter Plot, Antecedent-Behavior-Consequence record sheets and, finally, The Observer XT. We conducted a comprehensive assessment of challenging behavior of each participant, by reviewing bio-psychosocial records, interviewing family and direct caregiver staff, as well as direct observation. A large inter-subject behavior variability and instability of intra-subject behavior were found, raising questions about the election of the period to evaluate. The first evaluation level highlighted information about stability of behavior, the second level stand out the context in which it occurs and the third level detailed the different topographies of each behavioral category. The results suggest the desirability of a continuous assessment by combining these three levels for adjusting to the specific characteristics of behavior. We suggest the need of designing a single behavioral assessment procedure that includes the benefits observed in each of the instruments used.
Around-the-clock nursing care for the elderly in Japan.
Murashima, S; Zerwekh, J V; Yamada, M; Tagami, Y
1998-01-01
To describe the first phase of creating a Japanese model of community-based long-term care, called around-the-clock care (ACC), by operationally defining the components of ACC, identifying those eligible for the program, clarifying methods of planning and organization, and exploring outcomes. Exploratory evaluation for the population of frail elderly Japanese citizens living at home. A convenience sample of 44 patients receiving care from four visiting-nurse-service stations during 3 months in 1994 was used. Needs assessments; record reviews of patient encounters; evaluations by patients, families, and visiting nurses; and reviews of administrative data. Nurses perceived that ACC stabilized medical status, reduced the emotional and physical burden of treatment, and improved hygiene. It also reduced family caregiving burdens and the stress of family caregivers' employment responsibilities. The highest rating of ACC by patient and families was for those with the most complex physical needs. Skilled nursing at home permitted early identification and treatment of problems before they became crises or required hospitalization. Early findings suggest 24-hour nurse-home helper teamwork may be an effective system of community-based long-term care and should be considered a key element of future Japanese health policy.
NASA Technical Reports Server (NTRS)
Kobler, Benjamin (Editor); Hariharan, P. C. (Editor)
2000-01-01
This document contains copies of those technical papers received in time for publication prior to the Eighth Goddard Conference on Mass Storage Systems and Technologies which is being held in cooperation with the Seventeenth IEEE Symposium on Mass Storage Systems at the University of Maryland University College Inn and Conference Center March 27-30, 2000. As one of an ongoing series, this Conference continues to provide a forum for discussion of issues relevant to the management of large volumes of data. The Conference encourages all interested organizations to discuss long term mass storage requirements and experiences in fielding solutions. Emphasis is on current and future practical solutions addressing issues in data management, storage systems and media, data acquisition, long term retention of data, and data distribution. This year's discussion topics include architecture, future of current technology, new technology with a special emphasis on holographic storage, performance, standards, site reports, vendor solutions. Tutorials will be available on stability of optical media, disk subsystem performance evaluation, I/O and storage tuning, functionality and performance evaluation of file systems for storage area networks.
Measuring and communicating meaningful outcomes in neonatology: A family perspective.
Janvier, Annie; Farlow, Barbara; Baardsnes, Jason; Pearce, Rebecca; Barrington, Keith J
2016-12-01
Medium- and long-term outcomes have been collected and described among survivors of neonatal intensive care units for decades, for a number of purposes: (1) quality control within units, (2) comparisons of outcomes between NICUs, (3) clinical trials (whether an intervention improves outcomes), (4) end-of-life decision-making, (5) to better understand the effects of neonatal conditions and/or interventions on organs and/or long-term health, and finally (6) to better prepare parents for the future. However, the outcomes evaluated have been selected by investigators, based on feasibility, availability, cost, stability, and on what investigators consider to be important. Many of the routinely measured outcomes have major limitations: they may not correlate well with long-term difficulties, they may artificially divide continuous outcomes into dichotomous ones, and may have no clear relationship with quality of life and functioning of children and their families. Several investigations, such as routine term cerebral resonance imaging for preterm infants, have also not yet been shown to improve the outcome of children nor their families. In this article, the most common variables used in neonatology as well as some variables which are rarely measured but may be of equal importance for families are presented. The manner in which these outcomes are communicated to families will be examined, as well as recommendations to optimize communication with parents. Copyright © 2016 Elsevier Inc. All rights reserved.
Thermal and physicochemical properties important for the long term behavior of nuclear waste glasses
NASA Astrophysics Data System (ADS)
Matzke, Hj.; Vernaz, E.
High level nuclear waste from reprocessing of spent nuclear fuel has to be solidified in a stable matrix for safe long-time storage. Vitrification in borosilicate glasses is the technique accepted worldwide as the best combination of engineering constraints from fabrication and physicochemical properties of the matrix. A number of different glasses was developed in different national programs. The criteria and the reasons for selecting the final compositions are described briefly. Emphasis is placed on the French product R7T7 and on thermal and physicochemical properties though glasses developed in other national projects (e.g., the German product GP 98/12, etc.) are also treated. The basic physical and mechanical properties and the chemical durability of the glass in contact with water are described. The basic mechanisms of aqueous corrosion are discussed and the evolving modelling of the leaching process is dealt with, as well as effects of container material, backfill, etc. The thermal behavior has also been studied and extensive data exist on diffusion of glass constituents (Na) and of interesting elements of the waste such as the alkalis Rb and Cs or the actinides U and Pu, as well as on crystallization processes in the glass during storage at elevated temperatures. Emphasis is placed on the radiation stability of the glasses, based on extensive studies using short-lived actinides (e.g., 244Cm) or ion implantation to produce the damage expected during long storage at an accelerated rate. The radiation stability is shown to be very good, if realistic damage conditions are used. The knowledge accumulated in the past years is used to evaluate and predict the long-term evolution of the glass under storage conditions.
One- and two-stage Arrhenius models for pharmaceutical shelf life prediction.
Fan, Zhewen; Zhang, Lanju
2015-01-01
One of the most challenging aspects of the pharmaceutical development is the demonstration and estimation of chemical stability. It is imperative that pharmaceutical products be stable for two or more years. Long-term stability studies are required to support such shelf life claim at registration. However, during drug development to facilitate formulation and dosage form selection, an accelerated stability study with stressed storage condition is preferred to quickly obtain a good prediction of shelf life under ambient storage conditions. Such a prediction typically uses Arrhenius equation that describes relationship between degradation rate and temperature (and humidity). Existing methods usually rely on the assumption of normality of the errors. In addition, shelf life projection is usually based on confidence band of a regression line. However, the coverage probability of a method is often overlooked or under-reported. In this paper, we introduce two nonparametric bootstrap procedures for shelf life estimation based on accelerated stability testing, and compare them with a one-stage nonlinear Arrhenius prediction model. Our simulation results demonstrate that one-stage nonlinear Arrhenius method has significant lower coverage than nominal levels. Our bootstrap method gave better coverage and led to a shelf life prediction closer to that based on long-term stability data.
Chen, Tao; Chen, Liang; Li, Haicheng; Chen, Yuhui; Guo, Huixin; Shu, Yang; Chen, Zhiyu; Cai, Changhui; Guo, Lina; Zhang, Xianen; Zhou, Lin; Zhong, Qiu
2014-06-01
To overcome the undesirable side-effects of metronidazole (MTZ), ethylene glycol dimethacrylate is used as the cross-linker, and a series of poly(methacrylic acid) (PMAA) nanogels were prepared to load the MTZ. We investigated the morphology, size, in vitro release property in the simulated gastrointestinal medium, long-term antibacterial performance against Bacteroides fragilis, cytotoxicity, stability and activity of this novel MTZ/PMAA nanogel. The results indicate that the MTZ/PMAA nanogel sustained the release of MTZ in long-term antibacterial activity in the simulated gastrointestinal medium. This MTZ/PMAA nanogel exhibits less cytotoxicity than MTZ alone, suggesting that MTZ/PMAA nanogel is a more useful dosage form than MTZ for mild-to-moderate Clostridium difficile infections. The novel aspects of this study include the synthesis of a nanogel and the three-phase study of the release profile, which might be useful for other researchers in this field. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.
Šljukić, Biljana; Santos, Diogo M F; Vujković, Milica; Amaral, Luís; Rocha, Raquel P; Sequeira, César A C; Figueiredo, José L
2016-05-23
Low-cost molybdenum carbide (Mo2 C) nanoparticles supported on carbon nanotubes (CNTs) and on carbon xerogel (CXG) were prepared and their activity for the hydrogen evolution reaction (HER) was evaluated in 8 m KOH aqueous electrolyte at 25-85 °C. Measurements of the HER by linear scan voltammetry allowed us to determine Tafel slopes of 71 and 74 mV dec(-1) at 25 °C for Mo2 C/CNT and Mo2 C/CXG, respectively. Stability tests were also performed, which showed the steady performance of the two electrocatalysts. Moreover, the HER kinetics at Mo2 C/CNT was enhanced significantly after the long-term stability tests. The specific activity of both materials was high, and a higher stability was obtained for the activated Mo2 C/CNT (40 A g(-1) at -0.40 V vs. the reversible hydrogen electrode). © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Li, Mengran; Zhou, Wei; Zhu, Zhonghua
2017-01-25
Susceptibility to CO 2 is one of the major challenges for the long-term stability of the alkaline-earth-containing cathodes for intermediate-temperature solid oxide fuel cells. To alleviate the adverse effects from CO 2 , we incorporated samarium-stabilized ceria (SDC) into a SrCo 0.85 Ta 0.15 O 3-δ (SCT15) cathode by either mechanical mixing or a wet impregnation method and evaluated their cathode performance stability in the presence of a gas mixture of 10% CO 2 , 21% O 2 , and 69% N 2 . We observed that the CO 2 tolerance of the hybrid cathode outperforms the pure SCT15 cathode by over 5 times at 550 °C. This significant enhancement is likely attributable to the low CO 2 adsorption and reactivity of the SDC protective layer, which are demonstrated through thermogravimetric analysis, energy-dispersive spectroscopy, and electrical conductivity study.
NASA Astrophysics Data System (ADS)
Horníček, Leoš; Břešt'ovský, Petr; Jasanský, Petr
2017-09-01
The article deals with the application of a stabilization hexagonal geocomposite for the improvement of poor stability of railway tracks caused by undesirable migration of fine soil particles from the subgrade into the ballast bed. The establishment of a test railway section on a single-line track situated near Domazlice and its long-term monitoring programme are described. Evaluation is aimed especially at track geometry parameters, the load-bearing capacity of the ballast bed, elastic rail deflection during train passages and the durability of geocomposite’s physical properties. The data taken from the test section during five measurement campaigns are compared with both adjacent sections. In one of them, only the ballast bed renovation was carried out, whereas in the second one no intervention was performed at all. The usage of a pioneering geosynthetic product in combination with new trends in ballast bed restoration seems to be an innovative as well as effective solution to analogous problematic spots on railway tracks in the Czech Republic.
NASA Astrophysics Data System (ADS)
Ma, W.; Ma, Y.; Hu, Z.; Zhong, L.
2017-12-01
In this study, a land-atmosphere model was initialized by ingesting AMSR-E products, and the results were compared with the default model configuration and with in situ long-term CAMP/Tibet observations. Firstly our field observation sites will be introduced based on ITPCAS (Institute of Tibetan Plateau Research, Chinese Academy of Sciences). Then, a land-atmosphere model was initialized by ingesting AMSR-E products, and the results were compared with the default model configuration and with in situ long-term CAMP/Tibet observations. The differences between the AMSR-E initialized model runs with the default model configuration and in situ data showed an apparent inconsistency in the model-simulated land surface heat fluxes. The results showed that the soil moisture was sensitive to the specific model configuration. To evaluate and verify the model stability, a long-term modeling study with AMSR-E soil moisture data ingestion was performed. Based on test simulations, AMSR-E data were assimilated into an atmospheric model for July and August 2007. The results showed that the land surface fluxes agreed well with both the in situ data and the results of the default model configuration. Therefore, the simulation can be used to retrieve land surface heat fluxes from an atmospheric model over the Tibetan Plateau.
Josiassen, Richard C.; Kane, John M.; Liang, Grace S.; Burke, Joshua; O’Brien, Christopher F.
2017-01-01
Background The short-term safety profile of once-daily valbenazine (NBI-98854) has been evaluated in several double-blind, placebo-controlled (DBPC) trials in adults with tardive dyskinesia (TD) who had a diagnosis of schizophrenia/schizoaffective (SCHZ) disorder or mood disorder. Studies with longer treatment duration (up to 48 weeks) were conducted to evaluate the long-term safety of this novel drug in subjects with TD. Methods The pooled long-term exposure (LTE) population included valbenazine-treated subjects from 3 studies: KINECT (NCT01688037: 6-week DBPC, 6-week open-label); KINECT 3 (NCT02274558: 6-week DBPC, 42-week blinded extension, 4-week drug-free follow-up); KINECT 4 (NCT02405091: 48-week open-label, 4-week drug-free follow-up). Safety assessments included adverse events (AEs), laboratory tests, vital signs, electrocardiograms (ECGs), and extrapyramidal symptom (EPS) scales. Psychiatric stability was monitored using the Positive and Negative Syndrome Scale (PANSS) and Calgary Depression Scale for Schizophrenia (CDSS) (SCHZ subgroup), as well as the Montgomery-Åsberg Depression Rating Scale (MADRS) and Young Mania Rating Scale (YMRS) (mood subgroup). All data were analyzed descriptively. Results The LTE population included 430 subjects (KINECT, n = 46; KINECT 3, n = 220; KINECT 4, n = 164), 71.7% with SCHZ and 28.3% with a mood disorder; 85.5% were taking an antipsychotic (atypical only, 69.8%; typical only or typical + atypical, 15.7%). In the LTE population, treatment-emergent AEs (TEAEs) and discontinuations due to AEs were reported in 66.5% and 14.7% of subjects, respectively. The TEAE incidence was lower in the SCHZ subgroup (64.4%) than in the mood subgroup (71.9%). The 3 most common TEAEs in the SCHZ subgroup were urinary tract infection (UTI, 6.1%), headache (5.8%), and somnolence (5.2%). The 3 most common TEAEs in the mood subgroup were headache (12.4%), UTI (10.7%), and somnolence (9.1%). Mean score changes from baseline to end of treatment (Week 48) indicated that psychiatric stability was maintained in the SCHZ subgroup (PANSS Total, -3.4; PANSS Positive, -1.1; PANSS Negative, -0.1; PANSS General Psychopathology, -2.2; CDSS total, -0.4) and the mood subgroup (MADRS Total, 0.0; YMRS Total, -1.2). These scores remained generally stable during the 4-week drug-free follow-up periods. In the LTE population, mean changes in laboratory parameters, vital signs, ECG, and EPS scales were generally minimal and not clinically significant. Conclusion Valbenazine appeared to be well tolerated in adults with TD who received up to 48 weeks of treatment. In addition to long-term efficacy results (presented separately), these results suggest that valbenazine may be appropriate for the long-term management of TD regardless of underlying psychiatric diagnosis (SCHZ disorder or mood disorder). PMID:28839341
Josiassen, Richard C; Kane, John M; Liang, Grace S; Burke, Joshua; O'Brien, Christopher F
2017-08-01
The short-term safety profile of once-daily valbenazine (NBI-98854) has been evaluated in several double-blind, placebo-controlled (DBPC) trials in adults with tardive dyskinesia (TD) who had a diagnosis of schizophrenia/schizoaffective (SCHZ) disorder or mood disorder. Studies with longer treatment duration (up to 48 weeks) were conducted to evaluate the long-term safety of this novel drug in subjects with TD. The pooled long-term exposure (LTE) population included valbenazine-treated subjects from 3 studies: KINECT (NCT01688037: 6-week DBPC, 6-week open-label); KINECT 3 (NCT02274558: 6-week DBPC, 42-week blinded extension, 4-week drug-free follow-up); KINECT 4 (NCT02405091: 48-week open-label, 4-week drug-free follow-up). Safety assessments included adverse events (AEs), laboratory tests, vital signs, electrocardiograms (ECGs), and extrapyramidal symptom (EPS) scales. Psychiatric stability was monitored using the Positive and Negative Syndrome Scale (PANSS) and Calgary Depression Scale for Schizophrenia (CDSS) (SCHZ subgroup), as well as the Montgomery-Åsberg Depression Rating Scale (MADRS) and Young Mania Rating Scale (YMRS) (mood subgroup). All data were analyzed descriptively. The LTE population included 430 subjects (KINECT, n = 46; KINECT 3, n = 220; KINECT 4, n = 164), 71.7% with SCHZ and 28.3% with a mood disorder; 85.5% were taking an antipsychotic (atypical only, 69.8%; typical only or typical + atypical, 15.7%). In the LTE population, treatment-emergent AEs (TEAEs) and discontinuations due to AEs were reported in 66.5% and 14.7% of subjects, respectively. The TEAE incidence was lower in the SCHZ subgroup (64.4%) than in the mood subgroup (71.9%). The 3 most common TEAEs in the SCHZ subgroup were urinary tract infection (UTI, 6.1%), headache (5.8%), and somnolence (5.2%). The 3 most common TEAEs in the mood subgroup were headache (12.4%), UTI (10.7%), and somnolence (9.1%). Mean score changes from baseline to end of treatment (Week 48) indicated that psychiatric stability was maintained in the SCHZ subgroup (PANSS Total, -3.4; PANSS Positive, -1.1; PANSS Negative, -0.1; PANSS General Psychopathology, -2.2; CDSS total, -0.4) and the mood subgroup (MADRS Total, 0.0; YMRS Total, -1.2). These scores remained generally stable during the 4-week drug-free follow-up periods. In the LTE population, mean changes in laboratory parameters, vital signs, ECG, and EPS scales were generally minimal and not clinically significant. Valbenazine appeared to be well tolerated in adults with TD who received up to 48 weeks of treatment. In addition to long-term efficacy results (presented separately), these results suggest that valbenazine may be appropriate for the long-term management of TD regardless of underlying psychiatric diagnosis (SCHZ disorder or mood disorder).
Long-term (in)stability of the climate-streamflow relationship
NASA Astrophysics Data System (ADS)
Saft, Margarita; Peel, Murray; Coxon, Gemma; Freer, Jim; Parajka, Juraj; Woods, Ross
2017-04-01
Land use changes have long been known to alter streamflow production for a given climatic input. Recently, extended shifts in climate were also shown to be capable of altering catchment internal functioning and streamflow production for a given climatic input. This study investigates the stability of climate-streamflow relationships in natural catchments in different regions of the world for the first time, using datasets of natural/reference catchments from Europe, US, and Australia. Changes in climate-streamflow relationships are investigated statistically on the interannual to interdecadal timescale and related to interdecadal climate variability. We compare the frequency and magnitude of shifts in climate-streamflow relationship between different regions, and discuss what any differences in shift frequency and magnitude might be related to. This study draws attention to the issues of catchment vulnerability to changes in external factors, catchment-climate co-evolution, and long-term catchment memory.
Nagachinta, Supakana; Akoh, Casimir C
2013-10-01
Human milk fat (HMF) analogs are structured lipids (SLs) modified to have palmitic acid content at the sn-2 position of the triacylglycerol (TAG) and fatty acid composition comparable to HMF. Some of these SLs are also designed to incorporate long-chain polyunsaturated fatty acids (LCPUFAs) because of their important role in infant development. In this study, Maillard reaction products (MRPs), obtained from heated whey protein isolates and corn syrup solids (CSS) solution, were used as encapsulants for microencapsulation of 2 enzymatically synthesized SLs for infant formula applications. The encapsulated SL powders were obtained through spray-drying and evaluated in terms of their microencapsulation efficiency, chemical and physical properties, oxidative stability, and dispersibility. The microencapsulation efficiency of the SLs was 90%. Dispersibility test using particle size measurement demonstrated that these powders dispersed quickly into a homogeneous suspension. The encapsulated SL powders had low peroxide and thiobarbituric acid-reactive substances values. Lower oxidative stability was obtained in the powder containing SL with a higher degree of unsaturation and a lower concentration of tocopherols. The results demonstrated that the degree of fatty acid unsaturation and concentration of endogenous antioxidant in starting oils influenced the oxidative stability of the encapsulated SLs. © 2013 Institute of Food Technologists®
2006-11-01
initiatives. Political Stability Iraq’s Council of Representatives has passed key legislation to initiate the constitutional review process, to...facilitate foreign invest- ment, and to outline a process for region formation. Most important for long-term political stability is the success of...November 30, 2006 5 1. Stability and Security in Iraq 1.1 Political Stability 1.1.1 Steps to a Free and Self-Governing Iraq As detailed in the August
A discussion for stabilization time of carbon steel in atmospheric corrosion
NASA Astrophysics Data System (ADS)
Zhang, Zong-kai; Ma, Xiao-bing; Cai, Yi-kun
2017-09-01
Stabilization time is an important parameter in long-term prediction of carbon steel corrosion in atmosphere. The range of the stabilization time of carbon steel in atmospheric corrosion has been published in many scientific literatures. However, the results may not precise because engineering experiences is dominant. This paper deals with the recalculation of stabilization time based on ISO CORRAG program, and analyzes the results and makes a comparison to the data mentioned above. In addition, a new thinking to obtain stabilization time will be proposed.
The DOD Role in African Policy
1993-01-01
best hope for Africa’s long-term political stability . If democracy is indeed the political system best suited to cultural diversity, then it should...flourish in Africa. The United States should therefore strengthen programs, such as security assistance, that can enhance political stability while...involvement would seem to be a natural way to encourage democracy and political stability in Africa. To do so, however, DOD needs to maintain its
Wei, Ming-Li; Du, Yan-Jun; Reddy, Krishna R; Wu, Hao-Liang
2015-12-01
For viable and sustainable reuse of solidified/stabilized heavy metal-contaminated soils as roadway subgrade materials, long-term durability of these soils should be ensured. A new binder, KMP, has been developed for solidifying/stabilizing soils contaminated with high concentrations of heavy metals. However, the effects of long-term extreme weather conditions including freeze and thaw on the leachability and strength of the KMP stabilized contaminated soils have not been investigated. This study presents a systematic investigation on the impacts of freeze-thaw cycle on leachability, strength, and microstructural characteristics of the KMP stabilized soils spiked with Zn and Pb individually and together. For comparison purpose, Portland cement is also tested as a conventional binder. Several series of tests are conducted including the toxicity characteristic leaching procedure (TCLP), modified European Community Bureau of Reference (BCR) sequential extraction procedure, unconfined compression test (UCT), and mercury intrusion porosimetry (MIP). The results demonstrate that the freeze-thaw cycles have much less impact on the leachability and strength of the KMP stabilized soils as compared to the PC stabilized soils. After the freeze-thaw cycle tests, the KMP stabilized soils display much lower leachability, mass loss, and strength loss. These results are assessed based on the chemical speciation of Zn and Pb, and pore size distribution of the soils. Overall, this study demonstrates that the KMP stabilized heavy metal-contaminated soils perform well under the freeze-thaw conditions.
Examining the Long-Term Stability of Overgeneral Autobiographical Memory
Sumner, Jennifer A.; Mineka, Susan; Zinbarg, Richard E.; Craske, Michelle G.; Vrshek-Schallhorn, Suzanne; Epstein, Alyssa
2013-01-01
Overgeneral autobiographical memory (OGM) is a proposed trait-marker for vulnerability to depression, but relatively little work has examined its long-term stability. This study investigated the stability of OGM over several years in 271 late adolescents and young adults participating in a larger longitudinal study of risk for emotional disorders. The Autobiographical Memory Test (AMT) was administered twice, with test-retest intervals ranging from approximately 3 to 6 years. There was evidence of significant but modest stability in OGM over several years. Specifically, Spearman rank correlations (ρs) between the proportions of specific and categoric memories generated on the two AMTs were .31 and .32, respectively. We did not find evidence that the stability of OGM was moderated by the length of the test-retest interval. Furthermore, the stability coefficients for OGM for individuals with and without a lifetime history of major depressive disorder (MDD) were relatively similar in magnitude and not significantly different from one another (ρs = .34 and .42 for the proportions of specific and categoric memories for those with a history of MDD; ρs = .31 for both the proportions of specific and categoric memories for those without a history of MDD). Implications for the conceptualization of OGM are discussed. PMID:23439226
Pressure measurements with a precision of 0.001 ppm in magnetic fields at low temperatures
NASA Astrophysics Data System (ADS)
Miura, Y.; Matsushima, N.; Ando, T.; Kuno, S.; Inoue, S.; Ito, K.; Mamiya, T.
1993-11-01
Pressure measurements made by an ac bridge technique with a precision of 0.001 ppm in magnetic fields at low temperatures using a Straty-Adams type gauge are described. In order to improve the sensitivity and the long-term stability of the bridge system, coaxial cables without dielectric insulator were developed, with a small cable capacitance temperature coefficient of the impedance. This pressure measurement system has a sensitivity of dP/P˜5×10-10 and a long-term stability of dP/P˜2.4×10-9 over 18 h. This is especially useful for measurements such as electric and magnetic susceptibility measurements in magnetic fields at low temperatures requiring a high precision.
Şafak, K.; Xin, M.; Callahan, P. T.; Peng, M. Y.; Kärtner, F. X.
2015-01-01
We report recent progress made in a complete fiber-optic, high-precision, long-term stable timing distribution system for synchronization of next generation X-ray free-electron lasers. Timing jitter characterization of the master laser shows less than 170-as RMS integrated jitter for frequencies above 10 kHz, limited by the detection noise floor. Timing stabilization of a 3.5-km polarization-maintaining fiber link is successfully achieved with an RMS drift of 3.3 fs over 200 h of operation using all fiber-coupled elements. This all fiber-optic implementation will greatly reduce the complexity of optical alignment in timing distribution systems and improve the overall mechanical and timing stability of the system. PMID:26798814
Song, Woo Chul; Sung, Hye-Jin; Park, Kyung Soo; Choi, Jeong-Woo; Cho, Je-Yeol; Um, Soong Ho
2013-10-01
Fluorescent and luminescent chemical probes are essential in recent medical diagnostics. However, the use of these probes in vivo has raised concerns due to their low sensitivity, background signal interference, and non-biocompatibility. Therefore, biological chromophores have received much attention as new alternatives. In particular, luciferase, a class of oxidative enzyme with bioluminescence, has emerged as a promising fluorophore due to its improved biocompatibility. However, the enzyme usually possesses weaker luminescence and stability relative to its chemically-based competitors. Here, we report a novel functional mutant luciferase with both enhanced luminescence and long-term serum stability. For the preparation of the modified Renilla luciferase, a new bacterial subcloning design was established. The luciferase coding DNA sequence was redesigned so that mutant luciferase could be easily expressed in an Escherichia coli system. The mutant Renilla luciferase, which we called "m-Rluc," demonstrated characteristic enzymatic functions and showed a 5.6-fold increase in luminescence activity. In addition, the enzyme's physiological stability remained >80% for more than 5days, in contrast to conventional luciferase, termed "hrluc," which disappeared within a few hours. We suggest that this novel biological luciferase probe may be a great tool for both in vitro and in vivo medical diagnostics. Copyright © 2013 Elsevier Inc. All rights reserved.
Nadjmi, N; Schutyser, F; Van Erum, R
2006-10-01
Maxillary distraction osteogenesis is indicated in severe angle class III malocclusions, and severe maxillary hypoplasia among some cleft patients and other craniofacial deformities. Twenty patients, aged 8-48 years (mean 17.8+/-10.5 SD) with maxillary and midfacial hypoplasia were treated. The follow-up period was 13-65 months (mean 35+/-16.3 SD). A trans-sinusal maxillary distractor was placed intraorally at each side of the maxilla. The distraction vector was predicted using specialist software, and was transferred to the patients using stereolithographic models and individual templates. A (high) Le Fort I type osteotomy was performed. The amount of activation varied from 8 to 17.5 mm (mean 13.1+/-2.9 SD). Soft and hard tissue formation resulted in complete healing across the distraction gaps. The distractors are almost completely submerged, and can be left in place as long as necessary to avoid relapse. Wit's appraisal was used to measure the stability of the long-term distraction results. Results up to 5 years after distraction showed considerable maxillary advancement with long-term stability. Ongoing growth of the facial skeleton must be considered when distraction osteogenesis is chosen in growing patients.
Maternal Mental Illness and the Safety and Stability of Maltreated Children
ERIC Educational Resources Information Center
Kohl, Patricia L.; Jonson-Reid, Melissa; Drake, Brett
2011-01-01
Objective: Children of mothers with mental illness are at risk for multiple untoward outcomes, including child maltreatment and foster care placement. The purpose of this analysis was to determine the association between maternal mental illness and children's long term safety and stability. Methods: A multi-sector administrative dataset from the…
Long-term effects of seeding after wildfire on vegetation in Great Basin shrubland ecosystems
Kevin C. Knutson; David A. Pyke; Troy A. Wirth; Robert S. Arkle; David S. Pilliod; Matthew L. Brooks; Jeanne C. Chambers; James B. Grace
2014-01-01
Invasive annual grasses alter fire regimes in shrubland ecosystems of the western USA, threatening ecosystem function and fragmenting habitats necessary for shrub-obligate species such as greater sage-grouse. Post-fire stabilization and rehabilitation treatments have been administered to stabilize soils, reduce invasive species spread and restore or establish...
Retention of heavy metals by carboxyl functional groups of biochars in small arms range soil
USDA-ARS?s Scientific Manuscript database
Long-term effectiveness of biochar for heavy metal stabilization depends upon biochar’s sorptive property and recalcitrance in soil. To understand the role of carboxyl functional groups on heavy metal stabilization, cottonseed hull biochar and flax shive steam activated biochar having low O/C ratio...
Long-Term Stability of Screening for Behavioral and Emotional Risk
ERIC Educational Resources Information Center
Dowdy, Erin; Nylund-Gibson, Karen; Felix, Erika D.; Morovati, Diane; Carnazzo, Katherine W.; Dever, Bridget V.
2014-01-01
The practice of screening students to identify behavioral and emotional risk is gaining momentum, with limited guidance regarding the frequency with which screenings should occur. Screening frequency decisions are influenced by the stability of the constructs assessed and changes in risk status over time. This study investigated the 4-year…
30 CFR 819.19 - Auger mining: Backfilling and grading.
Code of Federal Regulations, 2010 CFR
2010-07-01
... safety factor for the stability of the backfill of at least 1.3. (2) All spoil generated by the auger... nonacid-, nontoxic-forming material and the backfill graded to a slope which is compatible with the approved postmining land use and which provides adequate drainage and long-term stability. (4) Any remnant...
Process and formulation effects on solar thermal drum dried prune pomace
USDA-ARS?s Scientific Manuscript database
The processing of dried plums into prune juice and concentrate yields prune pomace as a coproduct; the pomace could potentially be utilized as a food ingredient but requires stabilization for long-term storage. Drum drying is one method that could be used to dry and stabilize prune pomace, and a dru...
USDA-ARS?s Scientific Manuscript database
Cryptobiotic soil crusts in arid regions contribute to ecosystem stability through increased water infiltration, soil aggregate stability, and nutrient cycling between the soil community and vascular plants. Natural gas mining involves removal of the topsoil, including surface crust, and storage of ...
Factors Associated with Caregiver Stability in Permanent Placements: A Classification Tree Approach
ERIC Educational Resources Information Center
Proctor, Laura J.; Van Dusen Randazzo, Katherine; Litrownik, Alan J.; Newton, Rae R.; Davis, Inger P.; Villodas, Miguel
2011-01-01
Objective: Identify individual and environmental variables associated with caregiver stability and instability for children in diverse permanent placement types (i.e., reunification, adoption, and long-term foster care/guardianship with relatives or non-relatives), following 5 or more months in out-of-home care prior to age 4 due to substantiated…
Contribution of plant lignin to the soil organic matter formation and stabilization
USDA-ARS?s Scientific Manuscript database
Lignin is the third most abundant plant constituent after cellulose and hemicellulose and thought to be one of the building blocks for soil organic matter formation. Lignin can be used as a predictor for long-term soil organic matter stabilization and C sequestration. Soils and humic acids from fo...
Tica, D; Udovic, M; Lestan, D
2013-03-01
Remediation soil is exposed to various environmental factors over time that can affect the final success of the operation. In the present study, we assessed Pb bioaccessibility and microbial activity in industrially polluted soil (Arnoldstein, Austria) stabilized with 5% (w/w) of Slovakite and 5% (w/w) of apatite soil after exposure to two earthworm species, Lumbricus terrestris and Dendrobaena veneta, used as model environmental biotic soil factors. Stabilization resulted in reduced Pb bioaccessibility, as assessed with one-step extraction tests and six-step sequential extraction, and improved soil functioning, mirrored in reduced β-glucosidase activity in soil. Both earthworm species increased Pb bioaccessibility, thus decreasing the initial stabilization efficacy and indicating the importance of considering the long-term fate of remediated soil. The earthworm species had different effects on soil enzyme activity, which can be attributed to species-specific microbial populations in earthworm gut acting on the ingested soil. Copyright © 2012 Elsevier Ltd. All rights reserved.
Seo, Seongrok; Jeong, Seonghwa; Bae, Changdeuck; Park, Nam-Gyu; Shin, Hyunjung
2018-05-22
Despite the high power conversion efficiency (PCE) of perovskite solar cells (PSCs), poor long-term stability is one of the main obstacles preventing their commercialization. Several approaches to enhance the stability of PSCs have been proposed. However, an accelerating stability test of PSCs at high temperature under the operating conditions in ambient air remains still to be demonstrated. Herein, interface-engineered stable PSCs with inorganic charge-transport layers are shown. The highly conductive Al-doped ZnO films act as efficient electron-transporting layers as well as dense passivation layers. This layer prevents underneath perovskite from moisture contact, evaporation of components, and reaction with a metal electrode. Finally, inverted-type PSCs with inorganic charge-transport layers exhibit a PCE of 18.45% and retain 86.7% of the initial efficiency for 500 h under continuous 1 Sun illumination at 85 °C in ambient air with electrical biases (at maximum power point tracking). © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Fetherston, Susan M; Boyd, Peter; McCoy, Clare F; McBride, Marcella C; Edwards, Karen-Leigh; Ampofo, Stephen; Malcolm, R Karl
2013-02-14
Vaginal rings are currently being developed for the long-term (at least 30 days) continuous delivery of microbicides against human immunodeficiency virus (HIV). Research to date has mostly focused on devices containing a single antiretroviral compound, exemplified by the 25mg dapivirine ring currently being evaluated in a Phase III clinical study. However, there is a strong clinical rationale for combining antiretrovirals with different mechanisms of action in a bid to increase breadth of protection and limit the emergence of resistant strains. Here we report the development of a combination antiretroviral silicone elastomer matrix-type vaginal ring for simultaneous controlled release of dapivirine, a non-nucleoside reverse transcriptase inhibitor, and maraviroc, a CCR5-targeted HIV-1 entry inhibitor. Vaginal rings loaded with 25mg dapivirine and various quantities of maraviroc (50-400mg) were manufactured and in vitro release assessed. The 25mg dapivirine and 100mg maraviroc formulation was selected for further study. A 24-month pharmaceutical stability evaluation was conducted, indicating good product stability in terms of in vitro release, content assay, mechanical properties and related substances. This combination ring product has now progressed to Phase I clinical testing. Copyright © 2012 Elsevier B.V. All rights reserved.
Repair of Medial Patellofemoral, Ligament Improves Patellar, Tracking in Total Knee Replacement.
Meneghini, R Michael; Ziemba-Davis, Mary; Smits, Shelly; Bicos, James
2015-11-01
The medial patellofemoral ligament (MPFL) is essential to maintain patella stability; however, its role in total knee replacement (TKR) has not been studied. Forty-six consecutive TKRs in 40 patients were reviewed. Standard closure was performed in 29 TKRs. The MPFL was isolated and anatomically re-approximated in 17 subsequent TKRs. Blinded radiographic evaluation of patellar tilt and subluxation was performed preoperatively and 4 months postoperatively. Despite greater preoperative lateral tilt, the MPFL repair group demonstrated greater correction in patellar tilt compared with the standard closure group (p = 0.02). Patellar tracking also was optimized in the MPFL group, despite equivalent preoperative lateral patellar subluxation in the two groups. Simple repair of the MPFL at arthrotomy closure appears to optimize patellar stability radiographically and may improve long-term results by minimizing patellar complications and wear.
Long-term effects of seeding after wildfire on vegetation in Great Basin shrubland ecosystems
Knutson, Kevin C.; Pyke, David A.; Wirth, Troy A.; Arkle, Robert S.; Pilliod, David S.; Brooks, Matthew L.; Chambers, Jeanne C.; Grace, James B.
2014-01-01
1. Invasive annual grasses alter fire regimes in shrubland ecosystems of the western USA, threatening ecosystem function and fragmenting habitats necessary for shrub-obligate species such as greater sage-grouse. Post-fire stabilization and rehabilitation treatments have been administered to stabilize soils, reduce invasive species spread and restore or establish sustainable ecosystems in which native species are well represented. Long-term effectiveness of these treatments has rarely been evaluated. 2. We studied vegetation at 88 sites where aerial or drill seeding was implemented following fires between 1990 and 2003 in Great Basin (USA) shrublands. We examined sites on loamy soils that burned only once since 1970 to eliminate confounding effects of recurrent fire and to assess soils most conducive to establishment of seeded species. We evaluated whether seeding provided greater cover of perennial seeded species than burned–unseeded and unburned–unseeded sites, while also accounting for environmental variation. 3. Post-fire seeding of native perennial grasses generally did not increase cover relative to burned–unseeded areas. Native perennial grass cover did, however, increase after drill seeding when competitive non-natives were not included in mixes. Seeding non-native perennial grasses and the shrub Bassia prostrata resulted in more vegetative cover in aerial and drill seeding, with non-native perennial grass cover increasing with annual precipitation. Seeding native shrubs, particularly Artemisia tridentata, did not increase shrub cover or density in burned areas. Cover of undesirable, non-native annual grasses was lower in drill seeded relative to unseeded areas, but only at higher elevations. 4. Synthesis and applications. Management objectives are more likely to be met in high-elevation or precipitation locations where establishment of perennial grasses occurred. On lower and drier sites, management objectives are unlikely to be met with seeding alone. Intensive restoration methods such as invasive plant control and/or repeated sowings after establishment failures due to weather may be required in subsequent years. Managers might consider using native-only seed mixtures when establishment of native perennial grasses is the goal. Post-fire rehabilitation provides a land treatment example where long-term monitoring can inform adaptive management decisions to meet future objectives, particularly in arid landscapes where recovery is slow.
CO2 laser oscillators for laser radar applications
NASA Technical Reports Server (NTRS)
Freed, C.
1990-01-01
This paper reviews the spectral purity, frequency stability, and long-term stabilization of newly developed CO2 isotope lasers. Extremely high spectral purity, and short-term stability of less than 1.5 x 10 to the -13th have been achieved. A brief description on using CO2 isotope lasers as secondary frequency standards and in optical radar is given. The design and output characteristics of a single frequency, TEM00q mode, variable pulse width, hybrid TE CO2 laser system is also described. The frequency chirp in the output has been measured and almost completely eliminated by means of a novel technique.
Long-term risk analysis associated with nuclear waste disposal in space
NASA Technical Reports Server (NTRS)
Friedlander, A. L.; Davis, D. R.
1979-01-01
An assessment and verification of previous analytic results on the long term risk of earth reentry for hazardous payloads is presented. The two areas were studied: (1) stability of nominal, near-circular storage orbits in the regions between Venus and earth and between earth and Mars, and (2) probability of earth reentry for off-nominal planet-crossing orbits resulting from deployment system failures. In the first area, numerical integrations of the equations of motion are compared with stability predications based on secular perturbation theory. The agreement is good in terms of the heliocentric distances covered and the general behavior of the orbital history, although certain near-resonance situations can lead to difficulty. In the second area, a Monte Carlo simulation of orbital evolution is used and the results compared with Opik's analytic theory of planetary encounters and collision statistics, with data verified to within a close order-of-magnitude.
Luminosity determination in pp collisions at √{s} = 8 TeV using the ATLAS detector at the LHC
NASA Astrophysics Data System (ADS)
Aaboud, M.; Aad, G.; Abbott, B.; Abdallah, J.; Abdinov, O.; Abeloos, B.; Aben, R.; AbouZeid, O. S.; Abraham, N. L.; Abramowicz, H.; Abreu, H.; Abreu, R.; Abulaiti, Y.; Acharya, B. S.; Adamczyk, L.; Adams, D. L.; Adelman, J.; Adomeit, S.; Adye, T.; Affolder, A. A.; Agatonovic-Jovin, T.; Agricola, J.; Aguilar-Saavedra, J. A.; Ahlen, S. P.; Ahmadov, F.; Aielli, G.; Akerstedt, H.; Åkesson, T. P. A.; Akimov, A. V.; Alberghi, G. L.; Albert, J.; Albrand, S.; Verzini, M. J. Alconada; Aleksa, M.; Aleksandrov, I. N.; Alexa, C.; Alexander, G.; Alexopoulos, T.; Alhroob, M.; Aliev, M.; Alimonti, G.; Alison, J.; Alkire, S. P.; Allbrooke, B. M. M.; Allen, B. W.; Allport, P. P.; Aloisio, A.; Alonso, A.; Alonso, F.; Alpigiani, C.; Alstaty, M.; Gonzalez, B. Alvarez; Piqueras, D. Álvarez; Alviggi, M. G.; Amadio, B. T.; Amako, K.; Coutinho, Y. Amaral; Amelung, C.; Amidei, D.; Santos, S. P. Amor Dos; Amorim, A.; Amoroso, S.; Amundsen, G.; Anastopoulos, C.; Ancu, L. S.; Andari, N.; Andeen, T.; Anders, C. F.; Anders, G.; Anders, J. K.; Anderson, K. J.; Andreazza, A.; Andrei, V.; Angelidakis, S.; Angelozzi, I.; Anger, P.; Angerami, A.; Anghinolfi, F.; Anisenkov, A. V.; Anjos, N.; Annovi, A.; Antonelli, M.; Antonov, A.; Anulli, F.; Aoki, M.; Bella, L. Aperio; Arabidze, G.; Arai, Y.; Araque, J. P.; Arce, A. T. H.; Arduh, F. A.; Arguin, J.-F.; Argyropoulos, S.; Arik, M.; Armbruster, A. J.; Armitage, L. J.; Arnaez, O.; Arnold, H.; Arratia, M.; Arslan, O.; Artamonov, A.; Artoni, G.; Artz, S.; Asai, S.; Asbah, N.; Ashkenazi, A.; Åsman, B.; Asquith, L.; Assamagan, K.; Astalos, R.; Atkinson, M.; Atlay, N. B.; Augsten, K.; Avolio, G.; Axen, B.; Ayoub, M. K.; Azuelos, G.; Baak, M. A.; Baas, A. E.; Baca, M. J.; Bachacou, H.; Bachas, K.; Backes, M.; Backhaus, M.; Bagiacchi, P.; Bagnaia, P.; Bai, Y.; Baines, J. T.; Baker, O. K.; Baldin, E. M.; Balek, P.; Balestri, T.; Balli, F.; Balunas, W. K.; Banas, E.; Banerjee, Sw.; Bannoura, A. A. E.; Barak, L.; Barberio, E. L.; Barberis, D.; Barbero, M.; Barillari, T.; Barklow, T.; Barlow, N.; Barnes, S. L.; Barnett, B. M.; Barnett, R. M.; Barnovska, Z.; Baroncelli, A.; Barone, G.; Barr, A. J.; Navarro, L. Barranco; Barreiro, F.; da Costa, J. Barreiro Guimarães; Bartoldus, R.; Barton, A. E.; Bartos, P.; Basalaev, A.; Bassalat, A.; Bates, R. L.; Batista, S. J.; Batley, J. R.; Battaglia, M.; Bauce, M.; Bauer, F.; Bawa, H. S.; Beacham, J. B.; Beattie, M. D.; Beau, T.; Beauchemin, P. H.; Bechtle, P.; Beck, H. P.; Becker, K.; Becker, M.; Beckingham, M.; Becot, C.; Beddall, A. J.; Beddall, A.; Bednyakov, V. A.; Bedognetti, M.; Bee, C. P.; Beemster, L. J.; Beermann, T. A.; Begel, M.; Behr, J. K.; Belanger-Champagne, C.; Bell, A. S.; Bella, G.; Bellagamba, L.; Bellerive, A.; Bellomo, M.; Belotskiy, K.; Beltramello, O.; Belyaev, N. L.; Benary, O.; Benchekroun, D.; Bender, M.; Bendtz, K.; Benekos, N.; Benhammou, Y.; Noccioli, E. Benhar; Benitez, J.; Benjamin, D. P.; Bensinger, J. R.; Bentvelsen, S.; Beresford, L.; Beretta, M.; Berge, D.; Kuutmann, E. Bergeaas; Berger, N.; Beringer, J.; Berlendis, S.; Bernard, N. R.; Bernius, C.; Bernlochner, F. U.; Berry, T.; Berta, P.; Bertella, C.; Bertoli, G.; Bertolucci, F.; Bertram, I. A.; Bertsche, C.; Bertsche, D.; Besjes, G. J.; Bylund, O. Bessidskaia; Bessner, M.; Besson, N.; Betancourt, C.; Bethke, S.; Bevan, A. J.; Bhimji, W.; Bianchi, R. M.; Bianchini, L.; Bianco, M.; Biebel, O.; Biedermann, D.; Bielski, R.; Biesuz, N. V.; Biglietti, M.; De Mendizabal, J. Bilbao; Bilokon, H.; Bindi, M.; Binet, S.; Bingul, A.; Bini, C.; Biondi, S.; Bjergaard, D. M.; Black, C. W.; Black, J. E.; Black, K. M.; Blackburn, D.; Blair, R. E.; Blanchard, J.-B.; Blanco, J. E.; Blazek, T.; Bloch, I.; Blocker, C.; Blum, W.; Blumenschein, U.; Blunier, S.; Bobbink, G. J.; Bobrovnikov, V. S.; Bocchetta, S. S.; Bocci, A.; Bock, C.; Boehler, M.; Boerner, D.; Bogaerts, J. A.; Bogavac, D.; Bogdanchikov, A. G.; Bohm, C.; Boisvert, V.; Bokan, P.; Bold, T.; Boldyrev, A. S.; Bomben, M.; Bona, M.; Boonekamp, M.; Borisov, A.; Borissov, G.; Bortfeldt, J.; Bortoletto, D.; Bortolotto, V.; Bos, K.; Boscherini, D.; Bosman, M.; Sola, J. D. Bossio; Boudreau, J.; Bouffard, J.; Bouhova-Thacker, E. V.; Boumediene, D.; Bourdarios, C.; Boutle, S. K.; Boveia, A.; Boyd, J.; Boyko, I. R.; Bracinik, J.; Brandt, A.; Brandt, G.; Brandt, O.; Bratzler, U.; Brau, B.; Brau, J. E.; Braun, H. M.; Madden, W. D. Breaden; Brendlinger, K.; Brennan, A. J.; Brenner, L.; Brenner, R.; Bressler, S.; Bristow, T. M.; Britton, D.; Britzger, D.; Brochu, F. M.; Brock, I.; Brock, R.; Brooijmans, G.; Brooks, T.; Brooks, W. K.; Brosamer, J.; Brost, E.; Broughton, J. H.; de Renstrom, P. A. Bruckman; Bruncko, D.; Bruneliere, R.; Bruni, A.; Bruni, G.; Bruni, L. S.; Brunt, BH; Bruschi, M.; Bruscino, N.; Bryant, P.; Bryngemark, L.; Buanes, T.; Buat, Q.; Buchholz, P.; Buckley, A. G.; Budagov, I. A.; Buehrer, F.; Bugge, M. K.; Bulekov, O.; Bullock, D.; Burckhart, H.; Burdin, S.; Burgard, C. D.; Burghgrave, B.; Burka, K.; Burke, S.; Burmeister, I.; Busato, E.; Büscher, D.; Büscher, V.; Bussey, P.; Butler, J. M.; Buttar, C. M.; Butterworth, J. M.; Butti, P.; Buttinger, W.; Buzatu, A.; Buzykaev, A. R.; Urbán, S. Cabrera; Caforio, D.; Cairo, V. M.; Cakir, O.; Calace, N.; Calafiura, P.; Calandri, A.; Calderini, G.; Calfayan, P.; Caloba, L. P.; Calvet, D.; Calvet, S.; Calvet, T. P.; Toro, R. Camacho; Camarda, S.; Camarri, P.; Cameron, D.; Armadans, R. Caminal; Camincher, C.; Campana, S.; Campanelli, M.; Camplani, A.; Campoverde, A.; Canale, V.; Canepa, A.; Bret, M. Cano; Cantero, J.; Cantrill, R.; Cao, T.; Garrido, M. D. M. Capeans; Caprini, I.; Caprini, M.; Capua, M.; Caputo, R.; Carbone, R. M.; Cardarelli, R.; Cardillo, F.; Carli, I.; Carli, T.; Carlino, G.; Carminati, L.; Caron, S.; Carquin, E.; Carrillo-Montoya, G. D.; Carter, J. R.; Carvalho, J.; Casadei, D.; Casado, M. P.; Casolino, M.; Casper, D. W.; Castaneda-Miranda, E.; Castelijn, R.; Castelli, A.; Gimenez, V. Castillo; Castro, N. F.; Catinaccio, A.; Catmore, J. R.; Cattai, A.; Caudron, J.; Cavaliere, V.; Cavallaro, E.; Cavalli, D.; Cavalli-Sforza, M.; Cavasinni, V.; Ceradini, F.; Alberich, L. Cerda; Cerio, B. C.; Cerqueira, A. S.; Cerri, A.; Cerrito, L.; Cerutti, F.; Cerv, M.; Cervelli, A.; Cetin, S. A.; Chafaq, A.; Chakraborty, D.; Chan, S. K.; Chan, Y. L.; Chang, P.; Chapman, J. D.; Charlton, D. G.; Chatterjee, A.; Chau, C. C.; Barajas, C. A. Chavez; Che, S.; Cheatham, S.; Chegwidden, A.; Chekanov, S.; Chekulaev, S. V.; Chelkov, G. A.; Chelstowska, M. A.; Chen, C.; Chen, H.; Chen, K.; Chen, S.; Chen, S.; Chen, X.; Chen, Y.; Cheng, H. C.; Cheng, H. J.; Cheng, Y.; Cheplakov, A.; Cheremushkina, E.; Moursli, R. Cherkaoui El; Chernyatin, V.; Cheu, E.; Chevalier, L.; Chiarella, V.; Chiarelli, G.; Chiodini, G.; Chisholm, A. S.; Chitan, A.; Chizhov, M. V.; Choi, K.; Chomont, A. R.; Chouridou, S.; Chow, B. K. B.; Christodoulou, V.; Chromek-Burckhart, D.; Chudoba, J.; Chuinard, A. J.; Chwastowski, J. J.; Chytka, L.; Ciapetti, G.; Ciftci, A. K.; Cinca, D.; Cindro, V.; Cioara, I. A.; Ciocio, A.; Cirotto, F.; Citron, Z. H.; Citterio, M.; Ciubancan, M.; Clark, A.; Clark, B. L.; Clark, M. R.; Clark, P. J.; Clarke, R. N.; Clement, C.; Coadou, Y.; Cobal, M.; Coccaro, A.; Cochran, J.; Coffey, L.; Colasurdo, L.; Cole, B.; Colijn, A. P.; Collot, J.; Colombo, T.; Compostella, G.; Muiño, P. Conde; Coniavitis, E.; Connell, S. H.; Connelly, I. A.; Consorti, V.; Constantinescu, S.; Conti, G.; Conventi, F.; Cooke, M.; Cooper, B. D.; Cooper-Sarkar, A. M.; Cormier, K. J. R.; Cornelissen, T.; Corradi, M.; Corriveau, F.; Corso-Radu, A.; Cortes-Gonzalez, A.; Cortiana, G.; Costa, G.; Costa, M. J.; Costanzo, D.; Cottin, G.; Cowan, G.; Cox, B. E.; Cranmer, K.; Crawley, S. J.; Cree, G.; Crépé-Renaudin, S.; Crescioli, F.; Cribbs, W. A.; Ortuzar, M. Crispin; Cristinziani, M.; Croft, V.; Crosetti, G.; Donszelmann, T. Cuhadar; Cummings, J.; Curatolo, M.; Cúth, J.; Cuthbert, C.; Czirr, H.; Czodrowski, P.; D'amen, G.; D'Auria, S.; D'Onofrio, M.; De Sousa, M. J. Da Cunha Sargedas; Via, C. Da; Dabrowski, W.; Dado, T.; Dai, T.; Dale, O.; Dallaire, F.; Dallapiccola, C.; Dam, M.; Dandoy, J. R.; Dang, N. P.; Daniells, A. C.; Dann, N. S.; Danninger, M.; Hoffmann, M. Dano; Dao, V.; Darbo, G.; Darmora, S.; Dassoulas, J.; Dattagupta, A.; Davey, W.; David, C.; Davidek, T.; Davies, M.; Davison, P.; Dawe, E.; Dawson, I.; Daya-Ishmukhametova, R. K.; De, K.; de Asmundis, R.; De Benedetti, A.; De Castro, S.; De Cecco, S.; De Groot, N.; de Jong, P.; De la Torre, H.; De Lorenzi, F.; De Maria, A.; De Pedis, D.; De Salvo, A.; De Sanctis, U.; De Santo, A.; De Regie, J. B. De Vivie; Dearnaley, W. J.; Debbe, R.; Debenedetti, C.; Dedovich, D. V.; Dehghanian, N.; Deigaard, I.; Del Gaudio, M.; Del Peso, J.; Del Prete, T.; Delgove, D.; Deliot, F.; Delitzsch, C. M.; Deliyergiyev, M.; Dell'Acqua, A.; Dell'Asta, L.; Dell'Orso, M.; Della Pietra, M.; della Volpe, D.; Delmastro, M.; Delsart, P. A.; Deluca, C.; DeMarco, D. A.; Demers, S.; Demichev, M.; Demilly, A.; Denisov, S. P.; Denysiuk, D.; Derendarz, D.; Derkaoui, J. E.; Derue, F.; Dervan, P.; Desch, K.; Deterre, C.; Dette, K.; Deviveiros, P. O.; Dewhurst, A.; Dhaliwal, S.; Di Ciaccio, A.; Di Ciaccio, L.; Di Clemente, W. K.; Di Donato, C.; Di Girolamo, A.; Di Girolamo, B.; Di Micco, B.; Di Nardo, R.; Di Simone, A.; Di Sipio, R.; Di Valentino, D.; Diaconu, C.; Diamond, M.; Dias, F. A.; Diaz, M. A.; Diehl, E. B.; Dietrich, J.; Diglio, S.; Dimitrievska, A.; Dingfelder, J.; Dita, P.; Dita, S.; Dittus, F.; Djama, F.; Djobava, T.; Djuvsland, J. I.; do Vale, M. A. B.; Dobos, D.; Dobre, M.; Doglioni, C.; Dohmae, T.; Dolejsi, J.; Dolezal, Z.; Dolgoshein, B. A.; Donadelli, M.; Donati, S.; Dondero, P.; Donini, J.; Dopke, J.; Doria, A.; Dova, M. T.; Doyle, A. T.; Drechsler, E.; Dris, M.; Du, Y.; Duarte-Campderros, J.; Duchovni, E.; Duckeck, G.; Ducu, O. A.; Duda, D.; Dudarev, A.; Duffield, E. M.; Duflot, L.; Duguid, L.; Dührssen, M.; Dumancic, M.; Dunford, M.; Yildiz, H. Duran; Düren, M.; Durglishvili, A.; Duschinger, D.; Dutta, B.; Dyndal, M.; Eckardt, C.; Ecker, K. M.; Edgar, R. C.; Edwards, N. C.; Eifert, T.; Eigen, G.; Einsweiler, K.; Ekelof, T.; Kacimi, M. El; Ellajosyula, V.; Ellert, M.; Elles, S.; Ellinghaus, F.; Elliot, A. A.; Ellis, N.; Elmsheuser, J.; Elsing, M.; Emeliyanov, D.; Enari, Y.; Endner, O. C.; Endo, M.; Ennis, J. S.; Erdmann, J.; Ereditato, A.; Ernis, G.; Ernst, J.; Ernst, M.; Errede, S.; Ertel, E.; Escalier, M.; Esch, H.; Escobar, C.; Esposito, B.; Etienvre, A. I.; Etzion, E.; Evans, H.; Ezhilov, A.; Fabbri, F.; Fabbri, L.; Facini, G.; Fakhrutdinov, R. M.; Falciano, S.; Falla, R. J.; Faltova, J.; Fang, Y.; Fanti, M.; Farbin, A.; Farilla, A.; Farina, C.; Farooque, T.; Farrell, S.; Farrington, S. M.; Farthouat, P.; Fassi, F.; Fassnacht, P.; Fassouliotis, D.; Giannelli, M. Faucci; Favareto, A.; Fawcett, W. J.; Fayard, L.; Fedin, O. L.; Fedorko, W.; Feigl, S.; Feligioni, L.; Feng, C.; Feng, E. J.; Feng, H.; Fenyuk, A. B.; Feremenga, L.; Martinez, P. Fernandez; Perez, S. Fernandez; Ferrando, J.; Ferrari, A.; Ferrari, P.; Ferrari, R.; de Lima, D. E. Ferreira; Ferrer, A.; Ferrere, D.; Ferretti, C.; Parodi, A. Ferretto; Fiedler, F.; Filipčič, A.; Filipuzzi, M.; Filthaut, F.; Fincke-Keeler, M.; Finelli, K. D.; Fiolhais, M. C. N.; Fiorini, L.; Firan, A.; Fischer, A.; Fischer, C.; Fischer, J.; Fisher, W. C.; Flaschel, N.; Fleck, I.; Fleischmann, P.; Fletcher, G. T.; Fletcher, R. R. M.; Flick, T.; Floderus, A.; Castillo, L. R. Flores; Flowerdew, M. J.; Forcolin, G. T.; Formica, A.; Forti, A.; Foster, A. G.; Fournier, D.; Fox, H.; Fracchia, S.; Francavilla, P.; Franchini, M.; Francis, D.; Franconi, L.; Franklin, M.; Frate, M.; Fraternali, M.; Freeborn, D.; Fressard-Batraneanu, S. M.; Friedrich, F.; Froidevaux, D.; Frost, J. A.; Fukunaga, C.; Torregrosa, E. Fullana; Fusayasu, T.; Fuster, J.; Gabaldon, C.; Gabizon, O.; Gabrielli, A.; Gabrielli, A.; Gach, G. P.; Gadatsch, S.; Gadomski, S.; Gagliardi, G.; Gagnon, L. G.; Gagnon, P.; Galea, C.; Galhardo, B.; Gallas, E. J.; Gallop, B. J.; Gallus, P.; Galster, G.; Gan, K. K.; Gao, J.; Gao, Y.; Gao, Y. S.; Walls, F. M. Garay; García, C.; Navarro, J. E. García; Garcia-Sciveres, M.; Gardner, R. W.; Garelli, N.; Garonne, V.; Bravo, A. Gascon; Gatti, C.; Gaudiello, A.; Gaudio, G.; Gaur, B.; Gauthier, L.; Gavrilenko, I. L.; Gay, C.; Gaycken, G.; Gazis, E. N.; Gecse, Z.; Gee, C. N. P.; Geich-Gimbel, Ch.; Geisen, M.; Geisler, M. P.; Gemme, C.; Genest, M. H.; Geng, C.; Gentile, S.; George, S.; Gerbaudo, D.; Gershon, A.; Ghasemi, S.; Ghazlane, H.; Ghneimat, M.; Giacobbe, B.; Giagu, S.; Giannetti, P.; Gibbard, B.; Gibson, S. M.; Gignac, M.; Gilchriese, M.; Gillam, T. P. S.; Gillberg, D.; Gilles, G.; Gingrich, D. M.; Giokaris, N.; Giordani, M. P.; Giorgi, F. M.; Giorgi, F. M.; Giraud, P. F.; Giromini, P.; Giugni, D.; Giuli, F.; Giuliani, C.; Giulini, M.; Gjelsten, B. K.; Gkaitatzis, S.; Gkialas, I.; Gkougkousis, E. L.; Gladilin, L. K.; Glasman, C.; Glatzer, J.; Glaysher, P. C. F.; Glazov, A.; Goblirsch-Kolb, M.; Godlewski, J.; Goldfarb, S.; Golling, T.; Golubkov, D.; Gomes, A.; Gonçalo, R.; Costa, J. Goncalves Pinto Firmino Da; Gonella, G.; Gonella, L.; Gongadze, A.; de la Hoz, S. González; Parra, G. Gonzalez; Gonzalez-Sevilla, S.; Goossens, L.; Gorbounov, P. A.; Gordon, H. A.; Gorelov, I.; Gorini, B.; Gorini, E.; Gorišek, A.; Gornicki, E.; Goshaw, A. T.; Gössling, C.; Gostkin, M. I.; Goudet, C. R.; Goujdami, D.; Goussiou, A. G.; Govender, N.; Gozani, E.; Graber, L.; Grabowska-Bold, I.; Gradin, P. O. J.; Grafström, P.; Gramling, J.; Gramstad, E.; Grancagnolo, S.; Gratchev, V.; Gravila, P. M.; Gray, H. M.; Graziani, E.; Greenwood, Z. D.; Grefe, C.; Gregersen, K.; Gregor, I. M.; Grenier, P.; Grevtsov, K.; Griffiths, J.; Grillo, A. A.; Grimm, K.; Grinstein, S.; Gris, Ph.; Grivaz, J.-F.; Groh, S.; Grohs, J. P.; Gross, E.; Grosse-Knetter, J.; Grossi, G. C.; Grout, Z. J.; Guan, L.; Guan, W.; Guenther, J.; Guescini, F.; Guest, D.; Gueta, O.; Guido, E.; Guillemin, T.; Guindon, S.; Gul, U.; Gumpert, C.; Guo, J.; Guo, Y.; Gupta, S.; Gustavino, G.; Gutierrez, P.; Ortiz, N. G. Gutierrez; Gutschow, C.; Guyot, C.; Gwenlan, C.; Gwilliam, C. B.; Haas, A.; Haber, C.; Hadavand, H. K.; Haddad, N.; Hadef, A.; Haefner, P.; Hageböck, S.; Hajduk, Z.; Hakobyan, H.; Haleem, M.; Haley, J.; Halladjian, G.; Hallewell, G. D.; Hamacher, K.; Hamal, P.; Hamano, K.; Hamilton, A.; Hamity, G. N.; Hamnett, P. G.; Han, L.; Hanagaki, K.; Hanawa, K.; Hance, M.; Haney, B.; Hanke, P.; Hanna, R.; Hansen, J. B.; Hansen, J. D.; Hansen, M. C.; Hansen, P. H.; Hara, K.; Hard, A. S.; Harenberg, T.; Hariri, F.; Harkusha, S.; Harrington, R. D.; Harrison, P. F.; Hartjes, F.; Hartmann, N. M.; Hasegawa, M.; Hasegawa, Y.; Hasib, A.; Hassani, S.; Haug, S.; Hauser, R.; Hauswald, L.; Havranek, M.; Hawkes, C. M.; Hawkings, R. J.; Hayden, D.; Hays, C. P.; Hays, J. M.; Hayward, H. S.; Haywood, S. J.; Head, S. J.; Heck, T.; Hedberg, V.; Heelan, L.; Heim, S.; Heim, T.; Heinemann, B.; Heinrich, J. J.; Heinrich, L.; Heinz, C.; Hejbal, J.; Helary, L.; Hellman, S.; Helsens, C.; Henderson, J.; Henderson, R. C. W.; Heng, Y.; Henkelmann, S.; Correia, A. M. Henriques; Henrot-Versille, S.; Herbert, G. H.; Jiménez, Y. Hernández; Herten, G.; Hertenberger, R.; Hervas, L.; Hesketh, G. G.; Hessey, N. P.; Hetherly, J. W.; Hickling, R.; Higón-Rodriguez, E.; Hill, E.; Hill, J. C.; Hiller, K. H.; Hillier, S. J.; Hinchliffe, I.; Hines, E.; Hinman, R. R.; Hirose, M.; Hirschbuehl, D.; Hobbs, J.; Hod, N.; Hodgkinson, M. C.; Hodgson, P.; Hoecker, A.; Hoeferkamp, M. R.; Hoenig, F.; Hohn, D.; Holmes, T. R.; Homann, M.; Hong, T. M.; Hooberman, B. H.; Hopkins, W. H.; Horii, Y.; Horton, A. J.; Hostachy, J.-Y.; Hou, S.; Hoummada, A.; Howarth, J.; Hrabovsky, M.; Hristova, I.; Hrivnac, J.; Hryn'ova, T.; Hrynevich, A.; Hsu, C.; Hsu, P. J.; Hsu, S.-C.; Hu, D.; Hu, Q.; Huang, Y.; Hubacek, Z.; Hubaut, F.; Huegging, F.; Huffman, T. B.; Hughes, E. W.; Hughes, G.; Huhtinen, M.; Hülsing, T. A.; Huo, P.; Huseynov, N.; Huston, J.; Huth, J.; Iacobucci, G.; Iakovidis, G.; Ibragimov, I.; Iconomidou-Fayard, L.; Ideal, E.; Idrissi, Z.; Iengo, P.; Igonkina, O.; Iizawa, T.; Ikegami, Y.; Ikeno, M.; Ilchenko, Y.; Iliadis, D.; Ilic, N.; Ince, T.; Introzzi, G.; Ioannou, P.; Iodice, M.; Iordanidou, K.; Ippolito, V.; Ishino, M.; Ishitsuka, M.; Ishmukhametov, R.; Issever, C.; Istin, S.; Ito, F.; Ponce, J. M. Iturbe; Iuppa, R.; Iwanski, W.; Iwasaki, H.; Izen, J. M.; Izzo, V.; Jabbar, S.; Jackson, B.; Jackson, M.; Jackson, P.; Jain, V.; Jakobi, K. B.; Jakobs, K.; Jakobsen, S.; Jakoubek, T.; Jamin, D. O.; Jana, D. K.; Jansen, E.; Jansky, R.; Janssen, J.; Janus, M.; Jarlskog, G.; Javadov, N.; Javůrek, T.; Jeanneau, F.; Jeanty, L.; Jejelava, J.; Jeng, G.-Y.; Jennens, D.; Jenni, P.; Jentzsch, J.; Jeske, C.; Jézéquel, S.; Ji, H.; Jia, J.; Jiang, H.; Jiang, Y.; Jiggins, S.; Pena, J. Jimenez; Jin, S.; Jinaru, A.; Jinnouchi, O.; Johansson, P.; Johns, K. A.; Johnson, W. J.; Jon-And, K.; Jones, G.; Jones, R. W. L.; Jones, S.; Jones, T. J.; Jongmanns, J.; Jorge, P. M.; Jovicevic, J.; Ju, X.; Rozas, A. Juste; Köhler, M. K.; Kaczmarska, A.; Kado, M.; Kagan, H.; Kagan, M.; Kahn, S. J.; Kajomovitz, E.; Kalderon, C. W.; Kaluza, A.; Kama, S.; Kamenshchikov, A.; Kanaya, N.; Kaneti, S.; Kanjir, L.; Kantserov, V. A.; Kanzaki, J.; Kaplan, B.; Kaplan, L. S.; Kapliy, A.; Kar, D.; Karakostas, K.; Karamaoun, A.; Karastathis, N.; Kareem, M. J.; Karentzos, E.; Karnevskiy, M.; Karpov, S. N.; Karpova, Z. M.; Karthik, K.; Kartvelishvili, V.; Karyukhin, A. N.; Kasahara, K.; Kashif, L.; Kass, R. D.; Kastanas, A.; Kataoka, Y.; Kato, C.; Katre, A.; Katzy, J.; Kawagoe, K.; Kawamoto, T.; Kawamura, G.; Kazama, S.; Kazanin, V. F.; Keeler, R.; Kehoe, R.; Keller, J. S.; Kempster, J. J.; Kawade, K.; Keoshkerian, H.; Kepka, O.; Kerševan, B. P.; Kersten, S.; Keyes, R. A.; Khalil-zada, F.; Khanov, A.; Kharlamov, A. G.; Khoo, T. J.; Khovanskiy, V.; Khramov, E.; Khubua, J.; Kido, S.; Kim, H. Y.; Kim, S. H.; Kim, Y. K.; Kimura, N.; Kind, O. M.; King, B. T.; King, M.; King, S. B.; Kirk, J.; Kiryunin, A. E.; Kishimoto, T.; Kisielewska, D.; Kiss, F.; Kiuchi, K.; Kivernyk, O.; Kladiva, E.; Klein, M. H.; Klein, M.; Klein, U.; Kleinknecht, K.; Klimek, P.; Klimentov, A.; Klingenberg, R.; Klinger, J. A.; Klioutchnikova, T.; Kluge, E.-E.; Kluit, P.; Kluth, S.; Knapik, J.; Kneringer, E.; Knoops, E. B. F. G.; Knue, A.; Kobayashi, A.; Kobayashi, D.; Kobayashi, T.; Kobel, M.; Kocian, M.; Kodys, P.; Koffas, T.; Koffeman, E.; Koi, T.; Kolanoski, H.; Kolb, M.; Koletsou, I.; Komar, A. A.; Komori, Y.; Kondo, T.; Kondrashova, N.; Köneke, K.; König, A. C.; Kono, T.; Konoplich, R.; Konstantinidis, N.; Kopeliansky, R.; Koperny, S.; Köpke, L.; Kopp, A. K.; Korcyl, K.; Kordas, K.; Korn, A.; Korol, A. A.; Korolkov, I.; Korolkova, E. V.; Kortner, O.; Kortner, S.; Kosek, T.; Kostyukhin, V. V.; Kotwal, A.; Kourkoumeli-Charalampidi, A.; Kourkoumelis, C.; Kouskoura, V.; Kowalewska, A. B.; Kowalewski, R.; Kowalski, T. Z.; Kozakai, C.; Kozanecki, W.; Kozhin, A. S.; Kramarenko, V. A.; Kramberger, G.; Krasnopevtsev, D.; Krasny, M. W.; Krasznahorkay, A.; Kraus, J. K.; Kravchenko, A.; Kretz, M.; Kretzschmar, J.; Kreutzfeldt, K.; Krieger, P.; Krizka, K.; Kroeninger, K.; Kroha, H.; Kroll, J.; Kroseberg, J.; Krstic, J.; Kruchonak, U.; Krüger, H.; Krumnack, N.; Kruse, A.; Kruse, M. C.; Kruskal, M.; Kubota, T.; Kucuk, H.; Kuday, S.; Kuechler, J. T.; Kuehn, S.; Kugel, A.; Kuger, F.; Kuhl, A.; Kuhl, T.; Kukhtin, V.; Kukla, R.; Kulchitsky, Y.; Kuleshov, S.; Kuna, M.; Kunigo, T.; Kupco, A.; Kurashige, H.; Kurochkin, Y. A.; Kus, V.; Kuwertz, E. S.; Kuze, M.; Kvita, J.; Kwan, T.; Kyriazopoulos, D.; Rosa, A. La; Navarro, J. L. La Rosa; Rotonda, L. La; Lacasta, C.; Lacava, F.; Lacey, J.; Lacker, H.; Lacour, D.; Lacuesta, V. R.; Ladygin, E.; Lafaye, R.; Laforge, B.; Lagouri, T.; Lai, S.; Lammers, S.; Lampl, W.; Lançon, E.; Landgraf, U.; Landon, M. P. J.; Lang, V. S.; Lange, J. C.; Lankford, A. J.; Lanni, F.; Lantzsch, K.; Lanza, A.; Laplace, S.; Lapoire, C.; Laporte, J. F.; Lari, T.; Manghi, F. Lasagni; Lassnig, M.; Laurelli, P.; Lavrijsen, W.; Law, A. T.; Laycock, P.; Lazovich, T.; Lazzaroni, M.; Le, B.; Dortz, O. Le; Guirriec, E. Le; Quilleuc, E. P. Le; LeBlanc, M.; LeCompte, T.; Ledroit-Guillon, F.; Lee, C. A.; Lee, S. C.; Lee, L.; Lefebvre, G.; Lefebvre, M.; Legger, F.; Leggett, C.; Lehan, A.; Miotto, G. Lehmann; Lei, X.; Leight, W. A.; Leisos, A.; Leister, A. G.; Leite, M. A. L.; Leitner, R.; Lellouch, D.; Lemmer, B.; Leney, K. J. C.; Lenz, T.; Lenzi, B.; Leone, R.; Leone, S.; Leonidopoulos, C.; Leontsinis, S.; Lerner, G.; Leroy, C.; Lesage, A. A. J.; Lester, C. G.; Levchenko, M.; Levêque, J.; Levin, D.; Levinson, L. J.; Levy, M.; Lewis, D.; Leyko, A. M.; Leyton, M.; Li, B.; Li, H.; Li, H. L.; Li, L.; Li, L.; Li, Q.; Li, S.; Li, X.; Li, Y.; Liang, Z.; Liberti, B.; Liblong, A.; Lichard, P.; Lie, K.; Liebal, J.; Liebig, W.; Limosani, A.; Lin, S. C.; Lin, T. H.; Lindquist, B. E.; Lionti, A. E.; Lipeles, E.; Lipniacka, A.; Lisovyi, M.; Liss, T. M.; Lister, A.; Litke, A. M.; Liu, B.; Liu, D.; Liu, H.; Liu, H.; Liu, J.; Liu, J. B.; Liu, K.; Liu, L.; Liu, M.; Liu, M.; Liu, Y. L.; Liu, Y.; Livan, M.; Lleres, A.; Merino, J. Llorente; Lloyd, S. L.; Sterzo, F. Lo; Lobodzinska, E.; Loch, P.; Lockman, W. S.; Loebinger, F. K.; Loevschall-Jensen, A. E.; Loew, K. M.; Loginov, A.; Lohse, T.; Lohwasser, K.; Lokajicek, M.; Long, B. A.; Long, J. D.; Long, R. E.; Longo, L.; Looper, K. A.; Lopes, L.; Mateos, D. Lopez; Paredes, B. Lopez; Paz, I. Lopez; Solis, A. Lopez; Lorenz, J.; Martinez, N. Lorenzo; Losada, M.; Lösel, P. J.; Lou, X.; Lounis, A.; Love, J.; Love, P. A.; Lu, H.; Lu, N.; Lubatti, H. J.; Luci, C.; Lucotte, A.; Luedtke, C.; Luehring, F.; Lukas, W.; Luminari, L.; Lundberg, O.; Lund-Jensen, B.; Luzi, P. M.; Lynn, D.; Lysak, R.; Lytken, E.; Lyubushkin, V.; Ma, H.; Ma, L. L.; Ma, Y.; Maccarrone, G.; Macchiolo, A.; Macdonald, C. M.; Maček, B.; Miguens, J. Machado; Madaffari, D.; Madar, R.; Maddocks, H. J.; Mader, W. F.; Madsen, A.; Maeda, J.; Maeland, S.; Maeno, T.; Maevskiy, A.; Magradze, E.; Mahlstedt, J.; Maiani, C.; Maidantchik, C.; Maier, A. A.; Maier, T.; Maio, A.; Majewski, S.; Makida, Y.; Makovec, N.; Malaescu, B.; Malecki, Pa.; Maleev, V. P.; Malek, F.; Mallik, U.; Malon, D.; Malone, C.; Maltezos, S.; Malyukov, S.; Mamuzic, J.; Mancini, G.; Mandelli, B.; Mandelli, L.; Mandić, I.; Maneira, J.; Filho, L. Manhaes de Andrade; Ramos, J. Manjarres; Mann, A.; Manousos, A.; Mansoulie, B.; Mansour, J. D.; Mantifel, R.; Mantoani, M.; Manzoni, S.; Mapelli, L.; Marceca, G.; March, L.; Marchiori, G.; Marcisovsky, M.; Marjanovic, M.; Marley, D. E.; Marroquim, F.; Marsden, S. P.; Marshall, Z.; Marti-Garcia, S.; Martin, B.; Martin, T. A.; Martin, V. J.; Latour, B. Martin dit; Martinez, M.; Martin-Haugh, S.; Martoiu, V. S.; Martyniuk, A. C.; Marx, M.; Marzin, A.; Masetti, L.; Mashimo, T.; Mashinistov, R.; Masik, J.; Maslennikov, A. L.; Massa, I.; Massa, L.; Mastrandrea, P.; Mastroberardino, A.; Masubuchi, T.; Mättig, P.; Mattmann, J.; Maurer, J.; Maxfield, S. J.; Maximov, D. A.; Mazini, R.; Mazza, S. M.; Fadden, N. C. Mc; Goldrick, G. Mc; Kee, S. P. Mc; McCarn, A.; McCarthy, R. L.; McCarthy, T. G.; McClymont, L. I.; McDonald, E. F.; McFarlane, K. W.; Mcfayden, J. A.; Mchedlidze, G.; McMahon, S. J.; McPherson, R. A.; Medinnis, M.; Meehan, S.; Mehlhase, S.; Mehta, A.; Meier, K.; Meineck, C.; Meirose, B.; Melini, D.; Garcia, B. R. Mellado; Melo, M.; Meloni, F.; Menary, S. B.; Mengarelli, A.; Menke, S.; Meoni, E.; Mergelmeyer, S.; Mermod, P.; Merola, L.; Meroni, C.; Merritt, F. S.; Messina, A.; Metcalfe, J.; Mete, A. S.; Meyer, C.; Meyer, C.; Meyer, J.-P.; Meyer, J.; Theenhausen, H. Meyer Zu; Miano, F.; Middleton, R. P.; Miglioranzi, S.; Mijović, L.; Mikenberg, G.; Mikestikova, M.; Mikuž, M.; Milesi, M.; Milic, A.; Miller, D. W.; Mills, C.; Milov, A.; Milstead, D. A.; Minaenko, A. A.; Minami, Y.; Minashvili, I. A.; Mincer, A. I.; Mindur, B.; Mineev, M.; Ming, Y.; Mir, L. M.; Mistry, K. P.; Mitani, T.; Mitrevski, J.; Mitsou, V. A.; Miucci, A.; Miyagawa, P. S.; Mjörnmark, J. U.; Moa, T.; Mochizuki, K.; Mohapatra, S.; Molander, S.; Moles-Valls, R.; Monden, R.; Mondragon, M. C.; Mönig, K.; Monk, J.; Monnier, E.; Montalbano, A.; Berlingen, J. Montejo; Monticelli, F.; Monzani, S.; Moore, R. W.; Morange, N.; Moreno, D.; Llácer, M. Moreno; Morettini, P.; Mori, D.; Mori, T.; Morii, M.; Morinaga, M.; Morisbak, V.; Moritz, S.; Morley, A. K.; Mornacchi, G.; Morris, J. D.; Mortensen, S. S.; Morvaj, L.; Mosidze, M.; Moss, J.; Motohashi, K.; Mount, R.; Mountricha, E.; Mouraviev, S. V.; Moyse, E. J. W.; Muanza, S.; Mudd, R. D.; Mueller, F.; Mueller, J.; Mueller, R. S. P.; Mueller, T.; Muenstermann, D.; Mullen, P.; Mullier, G. A.; Sanchez, F. J. Munoz; Quijada, J. A. Murillo; Murray, W. J.; Musheghyan, H.; Muškinja, M.; Myagkov, A. G.; Myska, M.; Nachman, B. P.; Nackenhorst, O.; Nagai, K.; Nagai, R.; Nagano, K.; Nagasaka, Y.; Nagata, K.; Nagel, M.; Nagy, E.; Nairz, A. M.; Nakahama, Y.; Nakamura, K.; Nakamura, T.; Nakano, I.; Namasivayam, H.; Garcia, R. F. Naranjo; Narayan, R.; Villar, D. I. Narrias; Naryshkin, I.; Naumann, T.; Navarro, G.; Nayyar, R.; Neal, H. A.; Nechaeva, P. Yu.; Neep, T. J.; Nef, P. D.; Negri, A.; Negrini, M.; Nektarijevic, S.; Nellist, C.; Nelson, A.; Nemecek, S.; Nemethy, P.; Nepomuceno, A. A.; Nessi, M.; Neubauer, M. S.; Neumann, M.; Neves, R. M.; Nevski, P.; Newman, P. R.; Nguyen, D. H.; Manh, T. Nguyen; Nickerson, R. B.; Nicolaidou, R.; Nielsen, J.; Nikiforov, A.; Nikolaenko, V.; Nikolic-Audit, I.; Nikolopoulos, K.; Nilsen, J. K.; Nilsson, P.; Ninomiya, Y.; Nisati, A.; Nisius, R.; Nobe, T.; Nodulman, L.; Nomachi, M.; Nomidis, I.; Nooney, T.; Norberg, S.; Nordberg, M.; Norjoharuddeen, N.; Novgorodova, O.; Nowak, S.; Nozaki, M.; Nozka, L.; Ntekas, K.; Nurse, E.; Nuti, F.; O'grady, F.; O'Neil, D. C.; O'Rourke, A. A.; O'Shea, V.; Oakham, F. G.; Oberlack, H.; Obermann, T.; Ocariz, J.; Ochi, A.; Ochoa, I.; Ochoa-Ricoux, J. P.; Oda, S.; Odaka, S.; Ogren, H.; Oh, A.; Oh, S. H.; Ohm, C. C.; Ohman, H.; Oide, H.; Okawa, H.; Okumura, Y.; Okuyama, T.; Olariu, A.; Seabra, L. F. Oleiro; Pino, S. A. Olivares; Damazio, D. Oliveira; Olszewski, A.; Olszowska, J.; Onofre, A.; Onogi, K.; Onyisi, P. U. E.; Oreglia, M. J.; Oren, Y.; Orestano, D.; Orlando, N.; Orr, R. S.; Osculati, B.; Ospanov, R.; Garzon, G. Otero y.; Otono, H.; Ouchrif, M.; Ould-Saada, F.; Ouraou, A.; Oussoren, K. P.; Ouyang, Q.; Owen, M.; Owen, R. E.; Ozcan, V. E.; Ozturk, N.; Pachal, K.; Pages, A. Pacheco; Aranda, C. Padilla; Pagáčová, M.; Griso, S. Pagan; Paige, F.; Pais, P.; Pajchel, K.; Palacino, G.; Palestini, S.; Palka, M.; Pallin, D.; Palma, A.; Panagiotopoulou, E. St.; Pandini, C. E.; Vazquez, J. G. Panduro; Pani, P.; Panitkin, S.; Pantea, D.; Paolozzi, L.; Papadopoulou, Th. D.; Papageorgiou, K.; Paramonov, A.; Hernandez, D. Paredes; Parker, A. J.; Parker, M. A.; Parker, K. A.; Parodi, F.; Parsons, J. A.; Parzefall, U.; Pascuzzi, V. R.; Pasqualucci, E.; Passaggio, S.; Pastore, Fr.; Pásztor, G.; Pataraia, S.; Pater, J. R.; Pauly, T.; Pearce, J.; Pearson, B.; Pedersen, L. E.; Pedersen, M.; Lopez, S. Pedraza; Pedro, R.; Peleganchuk, S. V.; Pelikan, D.; Penc, O.; Peng, C.; Peng, H.; Penwell, J.; Peralva, B. S.; Perego, M. M.; Perepelitsa, D. V.; Codina, E. Perez; Perini, L.; Pernegger, H.; Perrella, S.; Peschke, R.; Peshekhonov, V. D.; Peters, K.; Peters, R. F. Y.; Petersen, B. A.; Petersen, T. C.; Petit, E.; Petridis, A.; Petridou, C.; Petroff, P.; Petrolo, E.; Petrov, M.; Petrucci, F.; Pettersson, N. E.; Peyaud, A.; Pezoa, R.; Phillips, P. W.; Piacquadio, G.; Pianori, E.; Picazio, A.; Piccaro, E.; Piccinini, M.; Pickering, M. A.; Piegaia, R.; Pilcher, J. E.; Pilkington, A. D.; Pin, A. W. J.; Pinamonti, M.; Pinfold, J. L.; Pingel, A.; Pires, S.; Pirumov, H.; Pitt, M.; Plazak, L.; Pleier, M.-A.; Pleskot, V.; Plotnikova, E.; Plucinski, P.; Pluth, D.; Poettgen, R.; Poggioli, L.; Pohl, D.; Polesello, G.; Poley, A.; Policicchio, A.; Polifka, R.; Polini, A.; Pollard, C. S.; Polychronakos, V.; Pommès, K.; Pontecorvo, L.; Pope, B. G.; Popeneciu, G. A.; Popovic, D. S.; Poppleton, A.; Pospisil, S.; Potamianos, K.; Potrap, I. N.; Potter, C. J.; Potter, C. T.; Poulard, G.; Poveda, J.; Pozdnyakov, V.; Astigarraga, M. E. Pozo; Pralavorio, P.; Pranko, A.; Prell, S.; Price, D.; Price, L. E.; Primavera, M.; Prince, S.; Proissl, M.; Prokofiev, K.; Prokoshin, F.; Protopopescu, S.; Proudfoot, J.; Przybycien, M.; Puddu, D.; Purohit, M.; Puzo, P.; Qian, J.; Qin, G.; Qin, Y.; Quadt, A.; Quayle, W. B.; Queitsch-Maitland, M.; Quilty, D.; Raddum, S.; Radeka, V.; Radescu, V.; Radhakrishnan, S. K.; Radloff, P.; Rados, P.; Ragusa, F.; Rahal, G.; Raine, J. A.; Rajagopalan, S.; Rammensee, M.; Rangel-Smith, C.; Ratti, M. G.; Rauscher, F.; Rave, S.; Ravenscroft, T.; Ravinovich, I.; Raymond, M.; Read, A. L.; Readioff, N. P.; Reale, M.; Rebuzzi, D. M.; Redelbach, A.; Redlinger, G.; Reece, R.; Reeves, K.; Rehnisch, L.; Reichert, J.; Reisin, H.; Rembser, C.; Ren, H.; Rescigno, M.; Resconi, S.; Rezanova, O. L.; Reznicek, P.; Rezvani, R.; Richter, R.; Richter, S.; Richter-Was, E.; Ricken, O.; Ridel, M.; Rieck, P.; Riegel, C. J.; Rieger, J.; Rifki, O.; Rijssenbeek, M.; Rimoldi, A.; Rimoldi, M.; Rinaldi, L.; Ristić, B.; Ritsch, E.; Riu, I.; Rizatdinova, F.; Rizvi, E.; Rizzi, C.; Robertson, S. H.; Robichaud-Veronneau, A.; Robinson, D.; Robinson, J. E. M.; Robson, A.; Roda, C.; Rodina, Y.; Perez, A. Rodriguez; Rodriguez, D. Rodriguez; Roe, S.; Rogan, C. S.; Røhne, O.; Romaniouk, A.; Romano, M.; Saez, S. M. Romano; Adam, E. Romero; Rompotis, N.; Ronzani, M.; Roos, L.; Ros, E.; Rosati, S.; Rosbach, K.; Rose, P.; Rosenthal, O.; Rosien, N.-A.; Rossetti, V.; Rossi, E.; Rossi, L. P.; Rosten, J. H. N.; Rosten, R.; Rotaru, M.; Roth, I.; Rothberg, J.; Rousseau, D.; Royon, C. R.; Rozanov, A.; Rozen, Y.; Ruan, X.; Rubbo, F.; Rudolph, M. S.; Rühr, F.; Ruiz-Martinez, A.; Rurikova, Z.; Rusakovich, N. A.; Ruschke, A.; Russell, H. L.; Rutherfoord, J. P.; Ruthmann, N.; Ryabov, Y. F.; Rybar, M.; Rybkin, G.; Ryu, S.; Ryzhov, A.; Rzehorz, G. F.; Saavedra, A. F.; Sabato, G.; Sacerdoti, S.; Sadrozinski, H. F.-W.; Sadykov, R.; Tehrani, F. Safai; Saha, P.; Sahinsoy, M.; Saimpert, M.; Saito, T.; Sakamoto, H.; Sakurai, Y.; Salamanna, G.; Salamon, A.; Loyola, J. E. Salazar; Salek, D.; De Bruin, P. H. Sales; Salihagic, D.; Salnikov, A.; Salt, J.; Salvatore, D.; Salvatore, F.; Salvucci, A.; Salzburger, A.; Sammel, D.; Sampsonidis, D.; Sanchez, A.; Sánchez, J.; Martinez, V. Sanchez; Sandaker, H.; Sandbach, R. L.; Sander, H. G.; Sandhoff, M.; Sandoval, C.; Sandstroem, R.; Sankey, D. P. C.; Sannino, M.; Sansoni, A.; Santoni, C.; Santonico, R.; Santos, H.; Castillo, I. Santoyo; Sapp, K.; Sapronov, A.; Saraiva, J. G.; Sarrazin, B.; Sasaki, O.; Sasaki, Y.; Sato, K.; Sauvage, G.; Sauvan, E.; Savage, G.; Savard, P.; Sawyer, C.; Sawyer, L.; Saxon, J.; Sbarra, C.; Sbrizzi, A.; Scanlon, T.; Scannicchio, D. A.; Scarcella, M.; Scarfone, V.; Schaarschmidt, J.; Schacht, P.; Schachtner, B. M.; Schaefer, D.; Schaefer, R.; Schaeffer, J.; Schaepe, S.; Schaetzel, S.; Schäfer, U.; Schaffer, A. C.; Schaile, D.; Schamberger, R. D.; Scharf, V.; Schegelsky, V. A.; Scheirich, D.; Schernau, M.; Schiavi, C.; Schier, S.; Schillo, C.; Schioppa, M.; Schlenker, S.; Schmidt-Sommerfeld, K. R.; Schmieden, K.; Schmitt, C.; Schmitt, S.; Schmitz, S.; Schneider, B.; Schnoor, U.; Schoeffel, L.; Schoening, A.; Schoenrock, B. D.; Schopf, E.; Schott, M.; Schovancova, J.; Schramm, S.; Schreyer, M.; Schuh, N.; Schultens, M. J.; Schultz-Coulon, H.-C.; Schulz, H.; Schumacher, M.; Schumm, B. A.; Schune, Ph.; Schwartzman, A.; Schwarz, T. A.; Schwegler, Ph.; Schweiger, H.; Schwemling, Ph.; Schwienhorst, R.; Schwindling, J.; Schwindt, T.; Sciolla, G.; Scuri, F.; Scutti, F.; Searcy, J.; Seema, P.; Seidel, S. C.; Seiden, A.; Seifert, F.; Seixas, J. M.; Sekhniaidze, G.; Sekhon, K.; Sekula, S. J.; Seliverstov, D. M.; Semprini-Cesari, N.; Serfon, C.; Serin, L.; Serkin, L.; Sessa, M.; Seuster, R.; Severini, H.; Sfiligoj, T.; Sforza, F.; Sfyrla, A.; Shabalina, E.; Shaikh, N. W.; Shan, L. Y.; Shang, R.; Shank, J. T.; Shapiro, M.; Shatalov, P. B.; Shaw, K.; Shaw, S. M.; Shcherbakova, A.; Shehu, C. Y.; Sherwood, P.; Shi, L.; Shimizu, S.; Shimmin, C. O.; Shimojima, M.; Shiyakova, M.; Shmeleva, A.; Saadi, D. Shoaleh; Shochet, M. J.; Shojaii, S.; Shrestha, S.; Shulga, E.; Shupe, M. A.; Sicho, P.; Sickles, A. M.; Sidebo, P. E.; Sidiropoulou, O.; Sidorov, D.; Sidoti, A.; Siegert, F.; Sijacki, Dj.; Silva, J.; Silverstein, S. B.; Simak, V.; Simard, O.; Simic, Lj.; Simion, S.; Simioni, E.; Simmons, B.; Simon, D.; Simon, M.; Sinervo, P.; Sinev, N. B.; Sioli, M.; Siragusa, G.; Sivoklokov, S. Yu.; Sjölin, J.; Sjursen, T. B.; Skinner, M. B.; Skottowe, H. P.; Skubic, P.; Slater, M.; Slavicek, T.; Slawinska, M.; Sliwa, K.; Slovak, R.; Smakhtin, V.; Smart, B. H.; Smestad, L.; Smiesko, J.; Smirnov, S. Yu.; Smirnov, Y.; Smirnova, L. N.; Smirnova, O.; Smith, M. N. K.; Smith, R. W.; Smizanska, M.; Smolek, K.; Snesarev, A. A.; Snyder, S.; Sobie, R.; Socher, F.; Soffer, A.; Soh, D. A.; Sokhrannyi, G.; Sanchez, C. A. Solans; Solar, M.; Soldatov, E. Yu.; Soldevila, U.; Solodkov, A. A.; Soloshenko, A.; Solovyanov, O. V.; Solovyev, V.; Sommer, P.; Son, H.; Song, H. Y.; Sood, A.; Sopczak, A.; Sopko, V.; Sorin, V.; Sosa, D.; Sotiropoulou, C. L.; Soualah, R.; Soukharev, A. M.; South, D.; Sowden, B. C.; Spagnolo, S.; Spalla, M.; Spangenberg, M.; Spanò, F.; Sperlich, D.; Spettel, F.; Spighi, R.; Spigo, G.; Spiller, L. A.; Spousta, M.; Denis, R. D. St.; Stabile, A.; Stamen, R.; Stamm, S.; Stanecka, E.; Stanek, R. W.; Stanescu, C.; Stanescu-Bellu, M.; Stanitzki, M. M.; Stapnes, S.; Starchenko, E. A.; Stark, G. H.; Stark, J.; Staroba, P.; Starovoitov, P.; Stärz, S.; Staszewski, R.; Steinberg, P.; Stelzer, B.; Stelzer, H. J.; Stelzer-Chilton, O.; Stenzel, H.; Stewart, G. A.; Stillings, J. A.; Stockton, M. C.; Stoebe, M.; Stoicea, G.; Stolte, P.; Stonjek, S.; Stradling, A. R.; Straessner, A.; Stramaglia, M. E.; Strandberg, J.; Strandberg, S.; Strandlie, A.; Strauss, M.; Strizenec, P.; Ströhmer, R.; Strom, D. M.; Stroynowski, R.; Strubig, A.; Stucci, S. A.; Stugu, B.; Styles, N. A.; Su, D.; Su, J.; Subramaniam, R.; Suchek, S.; Sugaya, Y.; Suk, M.; Sulin, V. V.; Sultansoy, S.; Sumida, T.; Sun, S.; Sun, X.; Sundermann, J. E.; Suruliz, K.; Susinno, G.; Sutton, M. R.; Suzuki, S.; Svatos, M.; Swiatlowski, M.; Sykora, I.; Sykora, T.; Ta, D.; Taccini, C.; Tackmann, K.; Taenzer, J.; Taffard, A.; Tafirout, R.; Taiblum, N.; Takai, H.; Takashima, R.; Takeshita, T.; Takubo, Y.; Talby, M.; Talyshev, A. A.; Tan, K. G.; Tanaka, J.; Tanaka, R.; Tanaka, S.; Tannenwald, B. B.; Araya, S. Tapia; Tapprogge, S.; Tarem, S.; Tartarelli, G. F.; Tas, P.; Tasevsky, M.; Tashiro, T.; Tassi, E.; Delgado, A. Tavares; Tayalati, Y.; Taylor, A. C.; Taylor, G. N.; Taylor, P. T. E.; Taylor, W.; Teischinger, F. A.; Teixeira-Dias, P.; Temming, K. K.; Temple, D.; Kate, H. Ten; Teng, P. K.; Teoh, J. J.; Tepel, F.; Terada, S.; Terashi, K.; Terron, J.; Terzo, S.; Testa, M.; Teuscher, R. J.; Theveneaux-Pelzer, T.; Thomas, J. P.; Thomas-Wilsker, J.; Thompson, E. N.; Thompson, P. D.; Thompson, A. S.; Thomsen, L. A.; Thomson, E.; Thomson, M.; Tibbetts, M. J.; Torres, R. E. Ticse; Tikhomirov, V. O.; Tikhonov, Yu. A.; Timoshenko, S.; Tipton, P.; Tisserant, S.; Todome, K.; Todorov, T.; Todorova-Nova, S.; Tojo, J.; Tokár, S.; Tokushuku, K.; Tolley, E.; Tomlinson, L.; Tomoto, M.; Tompkins, L.; Toms, K.; Tong, B.; Torrence, E.; Torres, H.; Pastor, E. Torró; Toth, J.; Touchard, F.; Tovey, D. R.; Trefzger, T.; Tricoli, A.; Trigger, I. M.; Trincaz-Duvoid, S.; Tripiana, M. F.; Trischuk, W.; Trocmé, B.; Trofymov, A.; Troncon, C.; Trottier-McDonald, M.; Trovatelli, M.; Truong, L.; Trzebinski, M.; Trzupek, A.; Tseng, J. C.-L.; Tsiareshka, P. V.; Tsipolitis, G.; Tsirintanis, N.; Tsiskaridze, S.; Tsiskaridze, V.; Tskhadadze, E. G.; Tsui, K. M.; Tsukerman, I. I.; Tsulaia, V.; Tsuno, S.; Tsybychev, D.; Tudorache, A.; Tudorache, V.; Tuna, A. N.; Tupputi, S. A.; Turchikhin, S.; Turecek, D.; Turgeman, D.; Turra, R.; Turvey, A. J.; Tuts, P. M.; Tyndel, M.; Ucchielli, G.; Ueda, I.; Ueno, R.; Ughetto, M.; Ukegawa, F.; Unal, G.; Undrus, A.; Unel, G.; Ungaro, F. C.; Unno, Y.; Unverdorben, C.; Urban, J.; Urquijo, P.; Urrejola, P.; Usai, G.; Usanova, A.; Vacavant, L.; Vacek, V.; Vachon, B.; Valderanis, C.; Santurio, E. Valdes; Valencic, N.; Valentinetti, S.; Valero, A.; Valery, L.; Valkar, S.; Vallecorsa, S.; Ferrer, J. A. Valls; Van Den Wollenberg, W.; Van Der Deijl, P. C.; van der Geer, R.; van der Graaf, H.; van Eldik, N.; van Gemmeren, P.; Van Nieuwkoop, J.; van Vulpen, I.; van Woerden, M. C.; Vanadia, M.; Vandelli, W.; Vanguri, R.; Vaniachine, A.; Vankov, P.; Vardanyan, G.; Vari, R.; Varnes, E. W.; Varol, T.; Varouchas, D.; Vartapetian, A.; Varvell, K. E.; Vasquez, J. G.; Vazeille, F.; Schroeder, T. Vazquez; Veatch, J.; Veloce, L. M.; Veloso, F.; Veneziano, S.; Ventura, A.; Venturi, M.; Venturi, N.; Venturini, A.; Vercesi, V.; Verducci, M.; Verkerke, W.; Vermeulen, J. C.; Vest, A.; Vetterli, M. C.; Viazlo, O.; Vichou, I.; Vickey, T.; Boeriu, O. E. Vickey; Viehhauser, G. H. A.; Viel, S.; Vigani, L.; Vigne, R.; Villa, M.; Perez, M. Villaplana; Vilucchi, E.; Vincter, M. G.; Vinogradov, V. B.; Vittori, C.; Vivarelli, I.; Vlachos, S.; Vlasak, M.; Vogel, M.; Vokac, P.; Volpi, G.; Volpi, M.; von der Schmitt, H.; von Toerne, E.; Vorobel, V.; Vorobev, K.; Vos, M.; Voss, R.; Vossebeld, J. H.; Vranjes, N.; Milosavljevic, M. Vranjes; Vrba, V.; Vreeswijk, M.; Vuillermet, R.; Vukotic, I.; Vykydal, Z.; Wagner, P.; Wagner, W.; Wahlberg, H.; Wahrmund, S.; Wakabayashi, J.; Walder, J.; Walker, R.; Walkowiak, W.; Wallangen, V.; Wang, C.; Wang, C.; Wang, F.; Wang, H.; Wang, H.; Wang, J.; Wang, J.; Wang, K.; Wang, R.; Wang, S. M.; Wang, T.; Wang, T.; Wang, W.; Wang, X.; Wanotayaroj, C.; Warburton, A.; Ward, C. P.; Wardrope, D. R.; Washbrook, A.; Watkins, P. M.; Watson, A. T.; Watson, M. F.; Watts, G.; Watts, S.; Waugh, B. M.; Webb, S.; Weber, M. S.; Weber, S. W.; Webster, J. S.; Weidberg, A. R.; Weinert, B.; Weingarten, J.; Weiser, C.; Weits, H.; Wells, P. S.; Wenaus, T.; Wengler, T.; Wenig, S.; Wermes, N.; Werner, M.; Werner, M. D.; Werner, P.; Wessels, M.; Wetter, J.; Whalen, K.; Whallon, N. L.; Wharton, A. M.; White, A.; White, M. J.; White, R.; Whiteson, D.; Wickens, F. J.; Wiedenmann, W.; Wielers, M.; Wienemann, P.; Wiglesworth, C.; Wiik-Fuchs, L. A. M.; Wildauer, A.; Wilk, F.; Wilkens, H. G.; Williams, H. H.; Williams, S.; Willis, C.; Willocq, S.; Wilson, J. A.; Wingerter-Seez, I.; Winklmeier, F.; Winston, O. J.; Winter, B. T.; Wittgen, M.; Wittkowski, J.; Wollstadt, S. J.; Wolter, M. W.; Wolters, H.; Wosiek, B. K.; Wotschack, J.; Woudstra, M. J.; Wozniak, K. W.; Wu, M.; Wu, M.; Wu, S. L.; Wu, X.; Wu, Y.; Wyatt, T. R.; Wynne, B. M.; Xella, S.; Xu, D.; Xu, L.; Yabsley, B.; Yacoob, S.; Yakabe, R.; Yamaguchi, D.; Yamaguchi, Y.; Yamamoto, A.; Yamamoto, S.; Yamanaka, T.; Yamauchi, K.; Yamazaki, Y.; Yan, Z.; Yang, H.; Yang, H.; Yang, Y.; Yang, Z.; Yao, W.-M.; Yap, Y. C.; Yasu, Y.; Yatsenko, E.; Wong, K. H. Yau; Ye, J.; Ye, S.; Yeletskikh, I.; Yen, A. L.; Yildirim, E.; Yorita, K.; Yoshida, R.; Yoshihara, K.; Young, C.; Young, C. J. S.; Youssef, S.; Yu, D. R.; Yu, J.; Yu, J. M.; Yu, J.; Yuan, L.; Yuen, S. P. Y.; Yusuff, I.; Zabinski, B.; Zaidan, R.; Zaitsev, A. M.; Zakharchuk, N.; Zalieckas, J.; Zaman, A.; Zambito, S.; Zanello, L.; Zanzi, D.; Zeitnitz, C.; Zeman, M.; Zemla, A.; Zeng, J. C.; Zeng, Q.; Zengel, K.; Zenin, O.; Ženiš, T.; Zerwas, D.; Zhang, D.; Zhang, F.; Zhang, G.; Zhang, H.; Zhang, J.; Zhang, L.; Zhang, R.; Zhang, R.; Zhang, X.; Zhang, Z.; Zhao, X.; Zhao, Y.; Zhao, Z.; Zhemchugov, A.; Zhong, J.; Zhou, B.; Zhou, C.; Zhou, L.; Zhou, L.; Zhou, M.; Zhou, N.; Zhu, C. G.; Zhu, H.; Zhu, J.; Zhu, Y.; Zhuang, X.; Zhukov, K.; Zibell, A.; Zieminska, D.; Zimine, N. I.; Zimmermann, C.; Zimmermann, S.; Zinonos, Z.; Zinser, M.; Ziolkowski, M.; Živković, L.; Zobernig, G.; Zoccoli, A.; Nedden, M. zur; Zurzolo, G.; Zwalinski, L.
2016-12-01
The luminosity determination for the ATLAS detector at the LHC during pp collisions at √{s} = 8 TeV in 2012 is presented. The evaluation of the luminosity scale is performed using several luminometers, and comparisons between these luminosity detectors are made to assess the accuracy, consistency and long-term stability of the results. A luminosity uncertainty of δ L/L = ± 1.9% is obtained for the 22.7 fb^{-1} of pp collision data delivered to ATLAS at √{s} = 8 TeV in 2012.
Space thermal control development
NASA Technical Reports Server (NTRS)
Hoover, M. J.; Grodzka, P. G.; Oneill, M. J.
1971-01-01
The results of experimental investigations on a number of various phase change materials (PCMs) and PCMs in combination with metals and other materials are reported. The evaluations include the following PCM system performance characteristics: PCM and PCM/filler thermal diffusivities, the effects of long-term thermal cycling, PCM-container compatibility, and catalyst effectiveness and stability. Three PCMs demonstrated performance acceptable enough to be considered for use in prototype aluminum thermal control devices. These three PCMs are lithium nitrate trihydrate with zinc hydroxy nitrate catalyst, acetamide, and myristic acid. Of the fillers tested, aluminum honeycomb filler was found to offer the most increase in system thermal diffusivity.
Aaboud, M.; Aad, G.; Abbott, B.; ...
2016-11-28
The luminosity determination for the ATLAS detector at the LHC during pp collisions atmore » $$\\sqrt{s} = 8$$ TeV in 2012 is presented. The evaluation of the luminosity scale is performed using several luminometers, and comparisons between these luminosity detectors are made to assess the accuracy, consistency and long-term stability of the results. A luminosity uncertainty of $δL/L$= ± 1.9% is obtained for the 22.7fb –1 of pp collision data delivered to ATLAS at $$\\sqrt{s} = 8$$ TeV in 2012.« less
Synaptic Scaling Enables Dynamically Distinct Short- and Long-Term Memory Formation
Tetzlaff, Christian; Kolodziejski, Christoph; Timme, Marc; Tsodyks, Misha; Wörgötter, Florentin
2013-01-01
Memory storage in the brain relies on mechanisms acting on time scales from minutes, for long-term synaptic potentiation, to days, for memory consolidation. During such processes, neural circuits distinguish synapses relevant for forming a long-term storage, which are consolidated, from synapses of short-term storage, which fade. How time scale integration and synaptic differentiation is simultaneously achieved remains unclear. Here we show that synaptic scaling – a slow process usually associated with the maintenance of activity homeostasis – combined with synaptic plasticity may simultaneously achieve both, thereby providing a natural separation of short- from long-term storage. The interaction between plasticity and scaling provides also an explanation for an established paradox where memory consolidation critically depends on the exact order of learning and recall. These results indicate that scaling may be fundamental for stabilizing memories, providing a dynamic link between early and late memory formation processes. PMID:24204240
Synaptic scaling enables dynamically distinct short- and long-term memory formation.
Tetzlaff, Christian; Kolodziejski, Christoph; Timme, Marc; Tsodyks, Misha; Wörgötter, Florentin
2013-10-01
Memory storage in the brain relies on mechanisms acting on time scales from minutes, for long-term synaptic potentiation, to days, for memory consolidation. During such processes, neural circuits distinguish synapses relevant for forming a long-term storage, which are consolidated, from synapses of short-term storage, which fade. How time scale integration and synaptic differentiation is simultaneously achieved remains unclear. Here we show that synaptic scaling - a slow process usually associated with the maintenance of activity homeostasis - combined with synaptic plasticity may simultaneously achieve both, thereby providing a natural separation of short- from long-term storage. The interaction between plasticity and scaling provides also an explanation for an established paradox where memory consolidation critically depends on the exact order of learning and recall. These results indicate that scaling may be fundamental for stabilizing memories, providing a dynamic link between early and late memory formation processes.
NASA Technical Reports Server (NTRS)
Friedlander, Alan
1991-01-01
A number of disposal options for space nuclear reactors and the associated risks, mostly in the long term, based on probabilities of Earth reentry are discussed. The results are based on a five year study that was conducted between 1978 and 1983 on the space disposal of high level nuclear waste. The study provided assessment of disposal options, stability of disposal or storage orbits, and assessment of the long term risks of Earth reentry of the nuclear waste.
An Autonomous Indicator-based pH Sensor for Oceanographic Research and Monitoring
2010-01-01
E-mail: michael.degrandpre@umontana.edu Co-PI: Jim Beck , MSME Sunburst Sensors, LLC, 1121 E. Broadway, Suite 114, Missoula, MT 59802 Phone...NOPP Award Number: ONR- BAA -07-040 NSF Award Number: OCE-0836807 LONG-TERM GOALS This project, funded under NOPP Topic 3A Sensors for...Spaulding continued work on establishing long- term stability of mCP. Jim Beck coordinated improvements to the design of the software and hardware
Lana, D; Di Russo, J; Mello, T; Wenk, G L; Giovannini, M G
2017-01-01
The present study was aimed at establishing whether the mTOR pathway and its downstream effector p70S6K in CA3 pyramidal neurons are under the modulation of the cholinergic input to trigger the formation of long term memories, similar to what we demonstrated in CA1 hippocampus. We performed in vivo behavioral experiments using the step down inhibitory avoidance test in adult Wistar rats to evaluate memory formation under different conditions. We examined the effects of rapamycin, an inhibitor of mTORC1 formation, scopolamine, a muscarinic receptor antagonist or mecamylamine, a nicotinic receptor antagonist, on short and long term memory formation and on the functionality of the mTOR pathway. Acquisition was conducted 30min after i.c.v. injection of rapamycin. Recall testing was performed 1h, 4h or 24h after acquisition. We found that (1) mTOR and p70S6K activation in CA3 pyramidal neurons were involved in long term memory formation; (2) rapamycin significantly inhibited mTOR and of p70S6K activation at 4h, and long term memory impairment 24h after acquisition; (3) scopolamine impaired short but not long term memory, with an early increase of mTOR/p70S6K activation at 1h followed by stabilization at longer times; (4) mecamylamine and scopolamine co-administration impaired short term memory at 1h and 4h and reduced the scopolamine-induced increase of mTOR/p70S6K activation at 1h and 4h; (5) mecamylamine and scopolamine treatment did not impair long term memory formation; (6) unexpectedly, rapamycin increased mTORC2 activation in microglial cells. Our results demonstrate that in CA3 pyramidal neurons the mTOR/p70S6K pathway is under the modulation of the cholinergic system and is involved in long-term memory encoding, and are consistent with the hypothesis that the CA3 region of the hippocampus is involved in memory mechanisms based on rapid, one-trial object-place learning and recall. Furthermore, our results are in accordance with previous reports that selective molecular mechanisms underlie either short term memory, long term memory, or both. Furthermore, our discovery that administration of rapamycin increased the activation of mTORC2 in microglial cells supports a reappraisal of the beneficial/adverse effects of rapamycin administration. Copyright © 2016 Elsevier Inc. All rights reserved.
Lana, D.; Di Russo, J.; Mello, T.; Wenk, G.L.; Giovannini, M.G.
2016-01-01
The present study was aimed at establishing whether the mTOR pathway and its downstream effector p70S6K in CA3 pyramidal neurons are under the modulation of the cholinergic input to trigger the formation of long term memories, similar to what we demonstrated in CA1 hippocampus. We performed in vivo behavioral experiments using the step down inhibitory avoidance test in adult Wistar rats to evaluate memory formation under different conditions. We examined the effects of rapamycin, an inhibitor of mTORC1 formation, scopolamine, a muscarinic receptor antagonist or mecamylamine, a nicotinic receptor antagonist, on short and long term memory formation and on the functionality of the mTOR pathway. Acquisition was conducted 30 min after i.c.v. injection of rapamycin. Recall testing was performed 1h, 4h or 24h after acquisition. We found that (1) mTOR and p70S6K activation in CA3 pyramidal neurons were involved in long term memory formation; (2) rapamycin significantly inhibited mTOR and of p70S6K activation at 4h, and long term memory impairment 24h after acquisition; (3) scopolamine impaired short but not long term memory, with an early increase of mTOR/p70S6K activation at 1h followed by stabilization at longer times; (4) mecamylamine and scopolamine co-administration impaired short term memory at 1h and 4h and reduced the scopolamine-induced increase of mTOR/p70S6K activation at 1h and 4h; (5) mecamylamine and scopolamine treatment did not impair long term memory formation; (6) unexpectedly, rapamycin increased mTORC2 activation in microglial cells. Our results demonstrate that in CA3 pyramidal neurons the mTOR/p70S6K pathway is under the modulation of the cholinergic system and is involved in long-term memory encoding, and are consistent with the hypothesis that the CA3 region of the hippocampus is involved in memory mechanisms based on rapid, one-trial object–place learning and recall. Furthermore, our results are in accordance with previous reports that selective molecular mechanisms underlie either short term memory, long term memory, or both. Furthermore, our discovery that administration of rapamycin increased the activation of mTORC2 in microglial cells supports a reappraisal of the beneficial/adverse effects of rapamycin administration. PMID:27838442
Variable presence of the inverted repeat and plastome stability in Erodium
Blazier, John C.; Jansen, Robert K.; Mower, Jeffrey P.; Govindu, Madhu; Zhang, Jin; Weng, Mao-Lun; Ruhlman, Tracey A.
2016-01-01
Background and Aims Several unrelated lineages such as plastids, viruses and plasmids, have converged on quadripartite genomes of similar size with large and small single copy regions and a large inverted repeat (IR). Except for Erodium (Geraniaceae), saguaro cactus and some legumes, the plastomes of all photosynthetic angiosperms display this structure. The functional significance of the IR is not understood and Erodium provides a system to examine the role of the IR in the long-term stability of these genomes. We compared the degree of genomic rearrangement in plastomes of Erodium that differ in the presence and absence of the IR. Methods We sequenced 17 new Erodium plastomes. Using 454, Illumina, PacBio and Sanger sequences, 16 genomes were assembled and categorized along with one incomplete and two previously published Erodium plastomes. We conducted phylogenetic analyses among these species using a dataset of 19 protein-coding genes and determined if significantly higher evolutionary rates had caused the long branch seen previously in phylogenetic reconstructions within the genus. Bioinformatic comparisons were also performed to evaluate plastome evolution across the genus. Key Results Erodium plastomes fell into four types (Type 1–4) that differ in their substitution rates, short dispersed repeat content and degree of genomic rearrangement, gene and intron content and GC content. Type 4 plastomes had significantly higher rates of synonymous substitutions (dS) for all genes and for 14 of the 19 genes non-synonymous substitutions (dN) were significantly accelerated. We evaluated the evidence for a single IR loss in Erodium and in doing so discovered that Type 4 plastomes contain a novel IR. Conclusions The presence or absence of the IR does not affect plastome stability in Erodium. Rather, the overall repeat content shows a negative correlation with genome stability, a pattern in agreement with other angiosperm groups and recent findings on genome stability in bacterial endosymbionts. PMID:27192713
Variable presence of the inverted repeat and plastome stability in Erodium.
Blazier, John C; Jansen, Robert K; Mower, Jeffrey P; Govindu, Madhu; Zhang, Jin; Weng, Mao-Lun; Ruhlman, Tracey A
2016-06-01
Several unrelated lineages such as plastids, viruses and plasmids, have converged on quadripartite genomes of similar size with large and small single copy regions and a large inverted repeat (IR). Except for Erodium (Geraniaceae), saguaro cactus and some legumes, the plastomes of all photosynthetic angiosperms display this structure. The functional significance of the IR is not understood and Erodium provides a system to examine the role of the IR in the long-term stability of these genomes. We compared the degree of genomic rearrangement in plastomes of Erodium that differ in the presence and absence of the IR. We sequenced 17 new Erodium plastomes. Using 454, Illumina, PacBio and Sanger sequences, 16 genomes were assembled and categorized along with one incomplete and two previously published Erodium plastomes. We conducted phylogenetic analyses among these species using a dataset of 19 protein-coding genes and determined if significantly higher evolutionary rates had caused the long branch seen previously in phylogenetic reconstructions within the genus. Bioinformatic comparisons were also performed to evaluate plastome evolution across the genus. Erodium plastomes fell into four types (Type 1-4) that differ in their substitution rates, short dispersed repeat content and degree of genomic rearrangement, gene and intron content and GC content. Type 4 plastomes had significantly higher rates of synonymous substitutions (dS) for all genes and for 14 of the 19 genes non-synonymous substitutions (dN) were significantly accelerated. We evaluated the evidence for a single IR loss in Erodium and in doing so discovered that Type 4 plastomes contain a novel IR. The presence or absence of the IR does not affect plastome stability in Erodium. Rather, the overall repeat content shows a negative correlation with genome stability, a pattern in agreement with other angiosperm groups and recent findings on genome stability in bacterial endosymbionts. © The Author 2016. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
A Perspective on Long-Term Recovery Following the Fukushima Nuclear Accident - 12075
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, S.Y.
2012-07-01
The tragic events at the Fukushima Daiichi Nuclear Power Station began occurring on March 11, 2011, following Japan's unprecedented earthquake and tsunami. The subsequent loss of external power and on-site cooling capacity severely compromised the plant's safety systems, and subsequently, led to core melt in the affected reactors and damage to spent nuclear fuel in the storage pools. Together with hydrogen explosions, this resulted in a substantial release of radioactive material to the environment (mostly Iodine-131 and Cesium- 137), prompting an extensive evacuation effort. The latest release estimate places the event at the highest severity level (Level 7) on themore » International Nuclear Event Scale, the same as the Chernobyl accident of 1986. As the utility owner endeavored to stabilize the damaged facility, environmental contamination continued to propagate and affect every aspect of daily life in the affected region of Japan. Elevated levels of radioactivity (mostly dominated by Cs-137 with the passage of time) were found in soil, drinking water, vegetation, produce, seafood, and other foodstuffs. An estimated 80,000 to 90,000 people were evacuated; more evacuations are being contemplated months after the accident, and a vast amount of land has become contaminated. Early actions were taken to ban the shipment and sale of contaminated food and drinking water, followed by later actions to ban the shipment and sale of contaminated beef, mushrooms, and seafood. As the event continues to evolve toward stabilization, the long-term recovery effort needs to commence - a process that doubtless will involve rather complex decision-making interactions between various stakeholders. Key issues that may be encountered and considered in such a process include (1) socio-political factors, (2) local economic considerations, (3) land use options, (4) remediation approaches, (5) decontamination methods, (6) radioactive waste management, (7) cleanup levels and options, and (8) government policies, among others. This paper offers a perspective on this likely long and arduous journey toward establishing a 'new normal' that will ultimately take shape. Toward this end, it is important to evaluate the 'optimization' process advocated by the international community in achieving long-term recovery from this particularly fateful event in Fukushima. In the process, experience and lessons learned from past events will be fully evaluated and considered. (author)« less
Ramos Yacasi, Gladys Rosario; Calpena Campmany, Ana Cristina; Egea Gras, María Antonia; Espina García, Marta; García López, María Luisa
2017-04-01
The stabilization of flurbiprofen loaded poly-ɛ-caprolactone nanoparticles (FB-PɛCL-NPs) for ocular delivery under accurate freeze-drying (FD) process provides the basis for a large-scale production and its commercial development. Optimization of the FD to improve long-term stability of ocular administration's FB-PɛCL-NPs. FB-PɛCL-NPs were prepared by solvent displacement method with poloxamer 188 (P188) as stabilizer. Freezing and primary drying (PD) were studied and optimized through freeze-thawing test and FD microscopy. Design of experiments was used to accurate secondary drying (SD) conditions and components concentration. Formulations were selected according to desired physicochemical properties. Furthermore, differential scanning calorimetry (DSC) and X-ray diffraction (XRD) were used to study interactions components. Optimized FB-PɛCL-NPs, stabilized with 3.5% (w/w) P188 and protected with 8% (w/w) poly(ethylene glycol), was submitted to precooling at +10 °C for 1 h, freezing at -50 °C for 4 h, PD at +5 °C and 0.140 mbar for 24 h and a SD at +45 °C during 10 h. These conditions showed 188.4 ± 1.3 nm, 0.087 ± 0.014, 85.5 ± 1.4%, 0.61 ± 0.12%, -16.4 ± 0.1 mV and 325 ± 7 mOsm/kg of average size, polydispersity index, entrapment efficiency, residual moisture, surface charge and osmolality, respectively. It performed a long-term stability >12 months. DSC and XRD spectra confirmed adequate chemical interaction between formulation components and showed a semi-crystalline state after FD. An optimal freeze dried ocular formulation was achieved. Evidently, the successful design of this promising colloidal system resulted from rational cooperation between a good formulation and the right conditions in the FD process.
Sommer, Yuliya L.; Ward, Cynthia D.; Pan, Yi; Caldwell, Kathleen L.; Jones, Robert L.
2016-01-01
In this study, we evaluated the effect of temperature on the long-term stability of three mercury species in bovine blood. We used inductively coupled plasma mass spectrometry (ICP-MS) analysis to determine the concentrations of inorganic (iHg), methyl (MeHg) and ethyl (EtHg) mercury species in two blood pools stored at temperatures of −70, −20, 4, 23°C (room temperature) and 37°C. Over the course of a year, we analyzed aliquots of pooled specimens at time intervals of 1, 2, 4 and 6 weeks and 2, 4, 6, 8, 10 and 12 months. We applied a fixed-effects linear model, step-down pairwise comparison and coefficient of variation statistical analysis to examine the temperature and time effects on changes in mercury species concentrations. We observed several instances of statistically significant differences in mercury species concentrations between different temperatures and time points; however, with considerations of experimental factors (such as instrumental drift and sample preparation procedures), not all differences were scientifically important. We concluded that iHg, MeHg and EtHg species in bovine whole blood were stable at −70, −20, 4 and 23°C for 1 year, but blood samples stored at 37°C were stable for no more than 2 weeks. PMID:26912563
Lee, Jihyun; Mitchell, Alyson E
2011-02-09
During onion processing, the outer dried protective layer (outer paper layer) and first two fleshy leaf layers are removed. This coproduct material is a potential commercial source of flavonoids especially quercetin. In the following study, the flavonoid composition was determined in coproduct materials and the press cake (material generated after juice extraction) in several commercially important onion varieties grown in California. Flavonoids were characterized and quantified using LC-(ESI)MS/MS and HPLC. The long-term stability of quercetin glycosides was assessed in dried coproduct materials stored at 4 and 22 °C over a 12 month period. In all varieties, the predominant forms of quercetin were the quercetin 3,4'-O-glucoside and 4'-O-glucoside. The first layer had significantly higher levels of flavonoids than the outer paper, second, and inner flesh layers on a DW basis (p < 0.05). Allium cepa "Milestone" contained the highest levels (p < 0.05) of flavonoids (1703 mg/100 g on a dry weight basis (DW). Onion press cake had significantly higher levels of total quercetin as compared with fresh onions (p < 0.05). The levels of 4'-O-glucoside significantly decreased during the first month of storage and remained stable for 12 months of storage at either 4 or 22 °C (p < 0.05).
Development and Long-Term Stability of a Novel Microbial Fuel Cell BOD Sensor with MnO2 Catalyst
Kharkwal, Shailesh; Tan, Yi Chao; Lu, Min; Ng, How Yong
2017-01-01
A novel microbial fuel cell (MFC)-based biosensor was designed for continuous monitoring of biochemical oxygen demand (BOD) in real wastewater. To lower the material cost, manganese dioxide (MnO2) was tested as an innovative cathode catalyst for oxygen reduction in a single chamber air-cathode MFC, and two different crystalline structures obtained during synthesis of MnO2 (namely β- and γ-MnO2) were compared. The BOD sensor was studied in a comprehensive way, using both sodium acetate solution and real domestic wastewater (DWW). The optimal performance of the sensor was obtained with a β-MnO2 catalyst, with R2 values of 0.99 and 0.98 using sodium acetate solution and DWW, respectively. The BOD values predicted by the β-MnO2 biosensor for DWW were in agreement with the BOD5 values, determined according to standard methods, with slight variations in the range from 3% to 12%. Finally, the long-term stability of the BOD biosensor was evaluated over 1.5 years. To the best of our knowledge, this is the first report of an MFC BOD sensor using an MnO2 catalyst at the cathode; the feasibility of using a low-cost catalyst in an MFC for online measurement of BOD in real wastewater broadens the scope of applications for such devices. PMID:28134838
Short- and long-term responses to molybdenum-99 shortages in nuclear medicine.
Ballinger, J R
2010-11-01
Most nuclear medicine studies use (99)Tc(m), which is the decay product of (99)Mo. The world supply of (99)Mo comes from only five nuclear research reactors and availability has been much reduced in recent times owing to problems at the largest reactors. In the short-term there are limited actions that can be taken owing to capacity issues on alternative imaging modalities. In the long-term, stability of (99)Mo supply will rely on a combination of replacing conventional reactors and developing new technologies.
Short- and long-term responses to molybdenum-99 shortages in nuclear medicine
Ballinger, J R
2010-01-01
Most nuclear medicine studies use 99Tcm, which is the decay product of 99Mo. The world supply of 99Mo comes from only five nuclear research reactors and availability has been much reduced in recent times owing to problems at the largest reactors. In the short-term there are limited actions that can be taken owing to capacity issues on alternative imaging modalities. In the long-term, stability of 99Mo supply will rely on a combination of replacing conventional reactors and developing new technologies. PMID:20965898
Wagner, Randall P.; Guthrie, William F.
2015-01-01
The devices calibrated most frequently by the acoustical measurement services at the National Institute of Standards and Technology (NIST) over the 50-year period from 1963 to 20121 were one-inch condenser microphones of three specific standard types: LS1Pn, LS1Po, and WS1P. Due to its long history of providing calibrations of such microphones to customers, NIST is in a unique position to analyze data concerning the long-term stability of these devices. This long history has enabled NIST to acquire and aggregate a substantial amount of repeat calibration data for a large number of microphones that belong to various other standards and calibration laboratories. In addition to determining microphone sensitivities at the time of calibration, it is important to have confidence that the microphones do not typically undergo significant drift as compared to the calibration uncertainty during the periods between calibrations. For each of the three microphone types, an average drift rate and approximate 95 % confidence interval were computed by two different statistical methods, and the results from the two methods were found to differ insignificantly in each case. These results apply to typical microphones of these types that are used in a suitable environment and handled with care. The average drift rate for Type LS1Pn microphones was −0.004 dB/year to 0.003 dB/year. The average drift rate for Type LS1Po microphones was −0.016 dB/year to 0.008 dB/year. The average drift rate for Type WS1P microphones was −0.004 dB/year to 0.018 dB/year. For each of these microphone types, the average drift rate is not significantly different from zero. This result is consistent with the performance expected of condenser microphones designed for use as transfer standards. In addition, the values that bound the confidence intervals are well within the limits specified for long-term stability in international standards. Even though these results show very good long-term stability historically for these microphone types, it is expected that periodic calibrations will always be done to track the calibration history of individual microphones and check for anomalies indicative of shifts in sensitivity. PMID:26958445
Improved Stability of a Model IgG3 by DoE-Based Evaluation of Buffer Formulations
Chavez, Brittany K.; Agarabi, Cyrus D.; Read, Erik K.; ...
2016-01-01
Formulating appropriate storage conditions for biopharmaceutical proteins is essential for ensuring their stability and thereby their purity, potency, and safety over their shelf-life. Using a model murine IgG3 produced in a bioreactor system, multiple formulation compositions were systematically explored in a DoE design to optimize the stability of a challenging antibody formulation worst case. The stability of the antibody in each buffer formulation was assessed by UV/VIS absorbance at 280 nm and 410 nm and size exclusion high performance liquid chromatography (SEC) to determine overall solubility, opalescence, and aggregate formation, respectively. Upon preliminary testing, acetate was eliminated as a potentialmore » storage buffer due to significant visible precipitate formation. An additional 2 4full factorial DoE was performed that combined the stabilizing effect of arginine with the buffering capacity of histidine. From this final DoE, an optimized formulation of 200 mM arginine, 50 mM histidine, and 100 mM NaCl at a pH of 6.5 was identified to substantially improve stability under long-term storage conditions and after multiple freeze/thaw cycles. Therefore, our data highlights the power of DoE based formulation screening approaches even for challenging monoclonal antibody molecules.« less
The Role of Actin Cytoskeleton in Dendritic Spines in the Maintenance of Long-Term Memory.
Basu, Sreetama; Lamprecht, Raphael
2018-01-01
Evidence indicates that long-term memory formation involves alterations in synaptic efficacy produced by modifications in neural transmission and morphology. However, it is not clear how such alterations induced by learning, that encode memory, are maintained over long period of time to preserve long-term memory. This is especially intriguing as the half-life of most of the proteins that underlie such changes is usually in the range of hours to days and these proteins may change their location over time. In this review we describe studies that indicate the involvement of dendritic spines in memory formation and its maintenance. These studies show that learning leads to changes in the number and morphology of spines. Disruption in spines morphology or manipulations that lead to alteration in their number after consolidation are associated with impairment in memory maintenance. We further ask how changes in dendritic spines morphology, induced by learning and reputed to encode memory, are maintained to preserve long-term memory. We propose a mechanism, based on studies described in the review, whereby the actin cytoskeleton and its regulatory proteins involved in the initial alteration in spine morphology induced by learning are also essential for spine structural stabilization that maintains long-term memory. In this model glutamate receptors and other synaptic receptors activation during learning leads to the creation of new actin cytoskeletal scaffold leading to changes in spines morphology and memory formation. This new actin cytoskeletal scaffold is preserved beyond actin and its regulatory proteins turnover and dynamics by active stabilization of the level and activity of actin regulatory proteins within these memory spines.
Long-Term Stability of the NIST Conical Reference Transducer.
Fick, Steven E; Proctor, Thomas M
2011-01-01
The National Institute of Standards and Technology (NIST) Conical Reference Transducer (CRT) is designed for purposes requiring frequency response characteristics much more uniform than those attainable with ultrasonic transducers conventionally used for acoustic emission (AE) nondestructive testing. The high performance of the CRT results from the use of design elements radically different from those of conventional transducers. The CRT was offered for sale for 15 years (1985 to 2000). Each CRT was furnished with data which expressed, as a function of frequency, the transducer sensitivity in volts per micrometer of normal displacement on the test block. Of the 22 transducers constructed, eight were reserved for long term research and were stored undisturbed in a laboratory with well controlled temperature and humidity. In 2009, the sensitivities of these eight units were redetermined. The 2009 data have been compared with data from similar tests conducted in 1985. The results of this comparison verify the claim "Results of tests of the long term stability of CRT characteristics indicate that, if proper care is taken, tens of years of service can reasonably be expected." made in the CRT specifications document furnished to prospective customers.
Film Grain-Size Related Long-Term Stability of Inverted Perovskite Solar Cells.
Chiang, Chien-Hung; Wu, Chun-Guey
2016-09-22
The power conversion efficiency (PCE) of the perovskite solar cell is high enough to be commercially viable. The next important issue is the stability of the device. This article discusses the effect of the perovskite grain-size on the long-term stability of inverted perovskite solar cells. Perovskite films composed of various sizes of grains were prepared by controlling the solvent annealing time. The grain-size related stability of the inverted cells was investigated both in ambient atmosphere at relative humidity of approximately 30-40 % and in a nitrogen filled glove box (H 2 O<0.1 ppm, O 2 <10 ppm). The PCE of the solar cell based on a perovskite film having the grain size larger than 1 μm (D-10) decreases less than 10 % with storage in a glove box and less than 15 % when it was stored under an ambient atmosphere for 30 days. However, the cell using the perovskite film composed of small (∼100 nm) perovskite grains (D-0) exhibits complete loss of PCE after storage under the ambient atmosphere for only 15 days and a PCE loss of up to 70 % with storage in the glove box for 30 days. These results suggest that, even under H 2 O-free conditions, the chemical- and thermal-induced production of pin holes at the grain boundaries of the perovskite film could be the reason for long-term instability of inverted perovskite solar cells. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Heo, Man Seung; Moon, Hyun Seok; Kim, Hee Chan; Park, Hyung Woo; Lim, Young Hoon; Paek, Sun Ha
2015-03-01
The purpose of this study to develop new deep-brain stimulation system for long-term use in animals, in order to develop a variety of neural prostheses. Our system has two distinguished features, which are the fully implanted system having wearable wireless power transfer and ability to change the parameter of stimulus parameter. It is useful for obtaining a variety of data from a long-term experiment. To validate our system, we performed pre-clinical test in Parkinson's disease-rat models for 4 weeks. Through the in vivo test, we observed the possibility of not only long-term implantation and stability, but also free movement of animals. We confirmed that the electrical stimulation neither caused any side effect nor damaged the electrodes. We proved possibility of our system to conduct the long-term pre-clinical test in variety of parameter, which is available for development of neural prostheses.