1999-12-01
1 alpha (MTP-la), macrophage inflammatory protein-2 (MIP-2), and acute phase reactive proteins ( Sabourin and Casillas, 1998; Casillas et ah, 1997...14. Sabourin , C.L.K., and R.P. Casillas. 1998. Inflammatory Gene Expression in Sulfur Mustard Exposed Mouse Skin. The Toxicologist, Vol. 42. 15
Strain-dependent dynamic compressive properties of magnetorheological elastomeric foams
NASA Astrophysics Data System (ADS)
Wereley, Norman M.; Perez, Colette; Choi, Young T.
2018-05-01
This paper addresses the strain-dependent dynamic compressive properties (i.e., so-called Payne effect) of magnetorheological elastomeric foams (MREFs). Isotropic MREF samples (i.e., no oriented particle chain structures), fabricated in flat square shapes (nominal size of 26.5 mm x 26.5 mm x 9.5 mm) were synthesized by randomly dispersing micron-sized iron oxide particles (Fe3O4) into a liquid silicone foam in the absence of magnetic field. Five different Fe3O4 particle concentrations of 0, 2.5, 5.0, 7.5, and 10 percent by volume fraction (hereinafter denoted as vol%) were used to investigate the effect of particle concentration on the dynamic compressive properties of the MREFs. The MREFs were sandwiched between two multi-pole flexible plate magnets in order to activate the magnetorheological (MR) strengthening effect. Under two different pre-compression conditions (i.e., 35% and 50%), the dynamic compressive stresses of the MREFs with respect to dynamic strain amplitudes (i.e., 1%-10%) were measured by using a servo-hydraulic testing machine. The complex modulus (i.e., storage modulus and loss modulus) and loss factors of the MREFs with respect to dynamic strain amplitudes were presented as performance indices to evaluate their strain-dependent dynamic compressive behavior.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olson, C.T.; Menton, R.G.; Kiser, R.C.
This task was conducted to determine the minimum dose of pyridostigmine (PYR), and the associated level of erythrocyte acetycholinesterase inhibition (AChE-I), that provides protection from 5 X 48-br GD LD50 of untreated monkeys. Monkeys were injected im with GD and treated with 0.4 mg atropine (ATR) free base and 25.7 mg pralidoxime (2-PAM) per kg BW.
1992-02-01
Snider, B.S., O.A.B.T. Date Study Supervisor I (.’ ’Quali tycsra-e Unit Date Health and Enviror snt Group . ... NTIS C7ŕ,1 DTIC IAtj U r, iv1: cu. 1v...the Federal Animal Welfare Act. Battelle’s statement of I] assurance regarding the Department of Health and Human Services policy on 4g I ] 1 humane...care of laboratory animals was accepted by the Office of Protection from Research Risks, National Institutes of Health , on August 27, 1973. Animals at
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joiner, R.L.; Hayes, L.; Rust, W.
1989-05-01
The following report summarizes the development and validation of an analytical method for the analyses of soman (GD), mustard (HD), VX, and tabun (GA) in wastewater. The need for an analytical method that can detect GD, HD, VX, and GA with the necessary sensitivity (< 20 parts per billion (PPB))and selectivity is essential to Medical Research and Evaluation Facility (MREF) operations. The analytical data were generated using liquid-liquid extraction of the wastewater, with the extract being concentrated and analyzed by gas chromatography (GC) methods. The sample preparation and analyses methods were developed in support of ongoing activities within the MREF.more » We have documented the precision and accuracy of the analytical method through an expected working calibration range (3.0 to 60 ppb). The analytical method was statistically evaluated over a range of concentrations to establish a detection limit and quantitation limit for the method. Whenever the true concentration is 8.5 ppb or above, the probability is at least 99.9 percent that the measured concentration will be ppb or above. Thus, 6 ppb could be used as a lower reliability limit for detecting concentrations in excess of 8.5 ppb. In summary, the proposed sample extraction and analyses methods are suitable for quantitative analyses to determine the presence of GD, HD, VX, and GA in wastewater samples. Our findings indicate that we can detect any of these chemical surety materiel (CSM) in water at or below the established U.S. Army Surgeon General's safety levels in drinking water.« less
In vivo screening of candidate pretreatment compounds against cyanide using mice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiser, R.C.; Olson, C.T.; Menton, R.G.
1993-05-13
An in vivo screening procedure was established at Battelle's Medical Research and Evaluation Facility (MREF) to evaluate the efficacy of candidate pretreatment compounds in mice challenged with the blood agent, sodium cyanide (NaCN). Male albino mice of ICR outbred stock weighing between 22.5 and 27.5 g are challenged by intramuscular (i.m.) injection, at a volume of 0.5 mL/kg, of a dose of NaCN twice the LD50 of untreated mice as determined on that day of testing. Candidate drugs are tested at fractions of their LD50 or their limit of solubility in the most optimum vehicle and given intraperitoneally (i.p.) tomore » separate groups of mice at either 60 or 15 min prior to NaCN challenge. Sodium thiosulfate (1000 mg/kg)/sodium nitrite (100 mg/kg) controls are injected i.p. only at 60 min prior to challenge. A test compound is deemed effective if, at any of three concentrations tested, or at either pretreatment time, it is statistically more efficacious in preventing lethality than is a negative control substance (candidate compound vehicle).« less
Validation of minicams for measuring concentrations of chemical agent in environmental air
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menton, R.G.; Hayes, T.L.; Chou, Y.L.
1993-05-13
Environmental monitoring for chemical agents is necessary to ensure that notification and appropriate action will be taken in the, event that there is a release exceeding control limits of such agents into the workplace outside of engineering controls. Prior to implementing new analytical procedures for environmental monitoring, precision and accuracy (PA) tests are conducted to ensure that an agent monitoring system performs according to specified accuracy, precision, and sensitivity requirements. This testing not only establishes the accuracy and precision of the method, but also determines what factors can affect the method's performance. Performance measures that are particularly important in agentmore » monitoring include the Detection Limit (DL), Decision Limit (DC), Found Action Level (FAL), and the Target Action Level (TAL). PA experiments were performed at Battelle's Medical Research and Evaluation Facility (MREF) to validate the use of the miniature chemical agent monitoring system (MINICAMs) for measuring environmental air concentrations of sulfur mustard (HD). This presentation discusses the experimental and statistical approaches for characterizing the performance of MINICAMS for measuring HD in air.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joiner, R.L.; Keys, W.B.; Harroff, H.H.
1988-02-18
A task was assigned to Battelle's Medical Research and Evaluation Facility(MREF) to evaluate the effectiveness of two candidate decontamination systems when compared to the standard dual component M258A1 decontamination system currently fielded by the U.S. Army. The chemical surety material (CSM) used in the evaluation were the organophosphates Soman (GD), polymer thickened GD (TGD), and VX, and the vesicants sulfur mustard (HD) and Lewisite (LS). The efficacies of the two candidate decontamination systems were evaluated in such a manner as to determine the LD50 and protective ratio (PR) for each decontaminant against each organophosphate CSM as compared to the standardmore » M258A1 decontamination system LD50. The PR constituted a comparison for each candidate system against the M258A1 standard. In the vesicant phase of the screen, the efficacies of the candidate systems were evaluated in a side-by-side comparison to the M258A1 decontamination system to determine whether the candidates were as good as or better than the standard dual component system.« less
1991-04-01
ORGAMLZflON WEORT NUMBSER(S) 6&. ftAAM OF PEFORAiNG ORGANUAlMN 61L OPF4C1 SYMSOL 7S. MAMA Of MO~ITORIMG ORGAJ.LATION Battelle Coluus Operations / U.S. Army...1) Nausea--possible vomiting. (2) Diarrhea. (3) Weakness. (4) Muscle twitching. (5) Convulsions. (6) Central nervous system depression . (7) Coma...by depressing the flame ignition button. Verify flame ignition by checking for continuous Revised February 19, 1990 Mp E MREF SOP-88-31 March 11, 1988
Parameterizations of Chromospheric Condensations in dG and dMe Model Flare Atmospheres
NASA Astrophysics Data System (ADS)
Kowalski, Adam F.; Allred, Joel C.
2018-01-01
The origin of the near-ultraviolet and optical continuum radiation in flares is critical for understanding particle acceleration and impulsive heating in stellar atmospheres. Radiative-hydrodynamic (RHD) simulations in 1D have shown that high energy deposition rates from electron beams produce two flaring layers at T ∼ 104 K that develop in the chromosphere: a cooling condensation (downflowing compression) and heated non-moving (stationary) flare layers just below the condensation. These atmospheres reproduce several observed phenomena in flare spectra, such as the red-wing asymmetry of the emission lines in solar flares and a small Balmer jump ratio in M dwarf flares. The high beam flux simulations are computationally expensive in 1D, and the (human) timescales for completing NLTE models with adaptive grids in 3D will likely be unwieldy for some time to come. We have developed a prescription for predicting the approximate evolved states, continuum optical depth, and emergent continuum flux spectra of RHD model flare atmospheres. These approximate prescriptions are based on an important atmospheric parameter: the column mass ({m}{ref}) at which hydrogen becomes nearly completely ionized at the depths that are approximately in steady state with the electron beam heating. Using this new modeling approach, we find that high energy flux density (>F11) electron beams are needed to reproduce the brightest observed continuum intensity in IRIS data of the 2014 March 29 X1 solar flare, and that variation in {m}{ref} from 0.001 to 0.02 g cm‑2 reproduces most of the observed range of the optical continuum flux ratios at the peak of M dwarf flares.
Grzyb, Tomasz; Przybylska, Dominika
2018-06-04
Ultrasmall (9-30 nm) Yb 3+ /Er 3+ -doped, upconverting alkaline rare-earth fluorides that are promising for future applications were synthesized by the microwave-assisted hydrothermal method. The formation mechanism was proposed, indicating the influence of the stability of metal ions complexes with ethylenediaminetetraacetic acid on the composition of the product and tendency to form M 2 REF 7 (M 0.67 RE 0.33 F 2.33 ) cubic compounds in the M-RE-F systems. Their physicochemical properties (structure, morphology, and spectroscopic properties) are compared and discussed. The obtained nanoparticles exhibited emission of light in the visible spectra under excitation by 976 nm laser radiation. Excitation and emission spectra, luminescence decays, laser energy dependencies, and upconversion quantum yields were measured to determine the spectroscopic properties of prepared materials. The Yb 3+ /Er 3+ pair of ions used as dopants was responsible for an intense yellowish-green emission. The upconversion quantum yields determined for the first time for M 2 REF 7 -based materials were 0.0192 ± 0.001% and 0.0176 ± 0.001% for Sr 2 LuF 7 :Yb 3+ ,Er 3+ and Ba 2 LuF 7 :Yb 3+ ,Er 3+ respectively, the two best emitting samples. These results indicated the prepared materials are good and promising alternatives for the most studied NaYF 4 :Yb 3+ ,Er 3+ nanoparticles.
Development and applications of nondestructive evaluation at Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
Whitaker, Ann F.
1990-01-01
A brief description of facility design and equipment, facility usage, and typical investigations are presented for the following: Surface Inspection Facility; Advanced Computer Tomography Inspection Station (ACTIS); NDE Data Evaluation Facility; Thermographic Test Development Facility; Radiographic Test Facility; Realtime Radiographic Test Facility; Eddy Current Research Facility; Acoustic Emission Monitoring System; Advanced Ultrasonic Test Station (AUTS); Ultrasonic Test Facility; and Computer Controlled Scanning (CONSCAN) System.
48 CFR 215.404-71-4 - Facilities capital employed.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., and equipment, as derived in DD Form 1861, Contract Facilities Capital Cost of Money. (i) In addition... facilities capital, the allocated facilities capital attributable to the buildings and equipment of those... Equipment 17.5 10 to 25 (g) Evaluation criteria. (1) In evaluating facilities capital employed, the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coles, G.A.; Shultz, M.V.; Taylor, W.E.
1993-09-01
This document provides a risk evaluation of the 100 and 200 Area retired, surplus facilities on the Hanford Site. Also included are the related data that were compiled by the risk evaluation team during investigations performed on the facilities. Results are the product of a major effort performed in fiscal year 1993 to produce qualitative information that characterizes certain risks associated with these facilities. The retired facilities investigated for this evaluation are located in the 100 and 200 Areas of the 1,450-km{sup 2} (570-mi{sup 2}) Hanford Site. The Hanford Site is a semiarid tract of land in southeastern Washington State.more » The nearest population center is Richland, Washington, (population 32,000) 30-km (20 mi) southeast of the 200 Area. During walkdown investigations of these facilities, data on real and potential hazards that threatened human health or safety or created potential environmental release issues were identified by the risk evaluation team. Using these findings, the team categorized the identified hazards by facility and evaluated the risk associated with each hazard. The factors contributing to each risk, and the consequence and likelihood of harm associated with each hazard also are included in this evaluation.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-21
.... Discussion Uranium recovery facility licensees, including in-situ recovery facilities and conventional... Recovery Facility Surveys of Radon and Radon Progeny in Air and Demonstrations of Compliance AGENCY... Staff Guidance, ``Evaluations of Uranium Recovery Facility Surveys of Radon and Radon Progeny in Air and...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eder, S.J.; Eli, M.W.; Salmon, M.W.
1993-11-01
The US Department of Energy (DOE) has a large inventory of existing facilities. Many of these facilities were not designed and constructed to current natural phenomena hazard (NPH) criteria. The NPH events include earthquakes, extreme winds and tornadoes, and floods. DOE Order 5480.28 establishes policy and requirements for NPH mitigation for DOE facilities. DOE is conducting a multiyear project to develop evaluation guidelines for assessing the condition and determining the need for upgrades at DOE facilities. One element of the NPH evaluation guidelines` development involves the existing systems and components at DOE facilities. This effort is described in detail inmore » a cited reference. In the interim period prior to availability of the final guidelines, DOE facilities are encouraged to implement an NPH walk through screening evaluation process by which systems and components that need attention can be rapidly identified. Guidelines for conducting the walk through screening evaluations are contained herein. The result of the NPH walk through screening evaluation should be a prioritized list of systems and components that need further action. Simple and inexpensive fixes for items identified in the walk through as marginal or inadequate should be implemented without further study. By implementing an NPH walk through screening evaluation, DOE facilities may realize significant reduction in risk from NPH in the short term.« less
47 CFR 73.7001 - Services subject to evaluation by point system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... evaluate mutually exclusive applications for new radio, television, and FM translator facilities, and for... mutually exclusive applications for new radio, television, and FM translator facilities, and for major... television translator and low power television facilities, and for major changes to existing facilities, only...
ERIC Educational Resources Information Center
Medlin, E. Lander; Judd, R. Holly
2013-01-01
APPA's Facilities Management Evaluation Program (FMEP) provides an integrated system to optimize organizational performance. The criteria for evaluation not only provide a tool for organizational continuous improvement, they serve as a compelling leadership development tool essential for today's facilities management professional. The senior…
Metrics for Success: Strategies for Enabling Core Facility Performance and Assessing Outcomes
Hockberger, Philip E.; Meyn, Susan M.; Nicklin, Connie; Tabarini, Diane; Auger, Julie A.
2016-01-01
Core Facilities are key elements in the research portfolio of academic and private research institutions. Administrators overseeing core facilities (core administrators) require assessment tools for evaluating the need and effectiveness of these facilities at their institutions. This article discusses ways to promote best practices in core facilities as well as ways to evaluate their performance across 8 of the following categories: general management, research and technical staff, financial management, customer base and satisfaction, resource management, communications, institutional impact, and strategic planning. For each category, we provide lessons learned that we believe contribute to the effective and efficient overall management of core facilities. If done well, we believe that encouraging best practices and evaluating performance in core facilities will demonstrate and reinforce the importance of core facilities in the research and educational mission of institutions. It will also increase job satisfaction of those working in core facilities and improve the likelihood of sustainability of both facilities and personnel. PMID:26848284
Metrics for Success: Strategies for Enabling Core Facility Performance and Assessing Outcomes.
Turpen, Paula B; Hockberger, Philip E; Meyn, Susan M; Nicklin, Connie; Tabarini, Diane; Auger, Julie A
2016-04-01
Core Facilities are key elements in the research portfolio of academic and private research institutions. Administrators overseeing core facilities (core administrators) require assessment tools for evaluating the need and effectiveness of these facilities at their institutions. This article discusses ways to promote best practices in core facilities as well as ways to evaluate their performance across 8 of the following categories: general management, research and technical staff, financial management, customer base and satisfaction, resource management, communications, institutional impact, and strategic planning. For each category, we provide lessons learned that we believe contribute to the effective and efficient overall management of core facilities. If done well, we believe that encouraging best practices and evaluating performance in core facilities will demonstrate and reinforce the importance of core facilities in the research and educational mission of institutions. It will also increase job satisfaction of those working in core facilities and improve the likelihood of sustainability of both facilities and personnel.
Evaluating Michigan commercial vehicle enforcement strategies and facilities.
DOT National Transportation Integrated Search
2015-03-01
This report documents evaluation results and recommendations for Michigan commercial vehicle : enforcement strategies and facilities. Through literature review, online survey and site visits, : enforcement strategies and facilities in other states an...
Nuclear thermal propulsion test facility requirements and development strategy
NASA Technical Reports Server (NTRS)
Allen, George C.; Warren, John; Clark, J. S.
1991-01-01
The Nuclear Thermal Propulsion (NTP) subpanel of the Space Nuclear Propulsion Test Facilities Panel evaluated facility requirements and strategies for nuclear thermal propulsion systems development. High pressure, solid core concepts were considered as the baseline for the evaluation, with low pressure concepts an alternative. The work of the NTP subpanel revealed that a wealth of facilities already exists to support NTP development, and that only a few new facilities must be constructed. Some modifications to existing facilities will be required. Present funding emphasis should be on long-lead-time items for the major new ground test facility complex and on facilities supporting nuclear fuel development, hot hydrogen flow test facilities, and low power critical facilities.
Surface evaluation of UV-degraded contamination
NASA Technical Reports Server (NTRS)
Connatser, Robert; Hadaway, James B.
1992-01-01
Three different areas of work were accomplished under this contract: (1) contamination testing and evaluation; (2) UV irradiation testing; and (3) surface evaluation testing. Contamination testing was generally performed in the In-Situ Contamination Effects Facility at Marshall Space Flight Center (MSFC). UV irradiation testing was also performed primarily at MSFC, utilizing facilities there. Finally, the surface evaluation was done at facilities at UAH Center for Applied Optics.
Natural phenomena hazards design and evaluation criteria for Department of Energy Facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-04-01
This DOE standard gives design and evaluation criteria for natural phenomena hazards (NPH) effects as guidance for implementing the NPH mitigation requirements of DOE 5480.28. Goal of the criteria is to assure that DOE facilities can withstand the effects of earthquakes, extreme winds, tornadoes, flooding, etc. They apply to the design of new facilities and the evaluation of existing facilities; they may also be used for modification and upgrading of the latter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kennedy, R.P.; Short, S.A.; McDonald, J.R.
1990-06-01
The Department of Energy (DOE) and the DOE Natural Phenomena Hazards Panel have developed uniform design and evaluation guidelines for protection against natural phenomena hazards at DOE sites throughout the United States. The goal of the guidelines is to assure that DOE facilities can withstand the effects of natural phenomena such as earthquakes, extreme winds, tornadoes, and flooding. The guidelines apply to both new facilities (design) and existing facilities (evaluation, modification, and upgrading). The intended audience is primarily the civil/structural or mechanical engineers conducting the design or evaluation of DOE facilities. The likelihood of occurrence of natural phenomena hazards atmore » each DOE site has been evaluated by the DOE Natural Phenomena Hazard Program. Probabilistic hazard models are available for earthquake, extreme wind/tornado, and flood. Alternatively, site organizations are encouraged to develop site-specific hazard models utilizing the most recent information and techniques available. In this document, performance goals and natural hazard levels are expressed in probabilistic terms, and design and evaluation procedures are presented in deterministic terms. Design/evaluation procedures conform closely to common standard practices so that the procedures will be easily understood by most engineers. Performance goals are expressed in terms of structure or equipment damage to the extent that: (1) the facility cannot function; (2) the facility would need to be replaced; or (3) personnel are endangered. 82 refs., 12 figs., 18 tabs.« less
Code of Federal Regulations, 2011 CFR
2011-07-01
... evaluation criteria for facilities that handle, store, or transport other non-petroleum oils. 154.1325...) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Response Plans for Other Non-Petroleum..., store, or transport other non-petroleum oils. (a) An owner or operator of a facility that handles...
Code of Federal Regulations, 2010 CFR
2010-07-01
... evaluation criteria for facilities that handle, store, or transport other non-petroleum oils. 154.1325...) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Response Plans for Other Non-Petroleum..., store, or transport other non-petroleum oils. (a) An owner or operator of a facility that handles...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Response plan development and... (CONTINUED) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Response Plans for Oil Facilities § 154.1045 Response plan development and evaluation criteria for facilities that handle, store, or...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Response plan development and... (CONTINUED) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Response Plans for Oil Facilities § 154.1045 Response plan development and evaluation criteria for facilities that handle, store, or...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Response plan development and... (CONTINUED) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Response Plans for Oil Facilities § 154.1045 Response plan development and evaluation criteria for facilities that handle, store, or...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Response plan development and... (CONTINUED) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS MATERIAL IN BULK Response Plans for Oil Facilities § 154.1045 Response plan development and evaluation criteria for facilities that handle, store, or...
Addressing social aspects associated with wastewater treatment facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Padilla-Rivera, Alejandro; Morgan-Sagastume, Juan Manuel; Noyola, Adalberto
In wastewater treatment facilities (WWTF), technical and financial aspects have been considered a priority, while other issues, such as social aspects, have not been evaluated seriously and there is not an accepted methodology for assessing it. In this work, a methodology focused on social concerns related to WWTF is presented. The methodology proposes the use of 25 indicators as a framework for measuring social performance to evaluate the progress in moving towards sustainability. The methodology was applied to test its applicability and effectiveness in two WWTF in Mexico (urban and rural). This evaluation helped define the key elements, stakeholders andmore » barriers in the facilities. In this context, the urban facility showed a better overall performance, a result that may be explained mainly by the better socioeconomic context of the urban municipality. Finally, the evaluation of social aspects using the semi-qualitative approach proposed in this work allows for a comparison between different facilities and for the identification of strengths and weakness, and it provides an alternative tool for achieving and improving wastewater management. - Highlights: • The methodology proposes 25 indicators as a framework for measuring social performance in wastewater treatment facilities. • The evaluation helped to define the key elements, stakeholders and barriers in the wastewater treatment facilities. • The evaluation of social aspects allows the identification of strengths and weakness for improving wastewater management. • It provides a social profile of the facility that highlights the best and worst performances.« less
VizieR Online Data Catalog: Photometric Calibration of SNLS (Regnault+, 2009)
NASA Astrophysics Data System (ADS)
Regnault, N.; Conley, A.; Guy, J.; Sullivan, M.; Cuillandre, J.-C.; Astier, P.; Balland, C.; Basa, S.; Carlberg, R. G.; Fouchez, D.; Hardin, D.; Hook, I. M.; Howell, D. A.; Pain, R.; Perrett, K.; Pritchet, C. J.
2009-08-01
This is the photometric calibration of the SuperNova Legacy Survey (SNLS) three year dataset. The SNLS corresponds to the DEEP component of the larger Canada-France-Hawaii Telescope Legacy Survey (CFHTLS). The SNLS repeatedly monitors four one square degree fields (labeled D[1-4]) with the MegaCam wide-field imager, in the g, r, i and z bands. u-band observations of the same fields are also available, although not formally part of the SNLS dataset. The non-uniformities of the MegaCam imager photometric response have been mapped as a function of the position on the focal plane. The fluxes, measured on the survey images processed with the CFHT Elixir pipeline, have been corrected for these non-uniformities in order to obtain measurements that are uniform at the ~1% level. The MegaCam passband transmissions were found to be non-uniform, the filters being 3 to 6 nanometers bluer on the edges of the camera than on the center. This result agrees with the filter scans provided by the filter manufacturer (Sagem/REOSC). This has important consequences on the definition of the MegaCam magnitudes: the natural magnitude system depends on the focal plane location where the observations were made. In order not to break the connection between calibrated magnitudes and their physical flux counterparts, we chose to report the *natural magnitudes* of each object, measured in the MegaCam passbands, at the focal plane location where the object was observed. We call this system, "Local Natural Magnitudes". The non-uniformities of the MegaCam effective passbands are small and, for main sequence stellar objects, they may be accounted for using linear color corrections. The relation between the Local Natural Magnitudes of a given star, observed at two locations x_0 and x of the focal plane are: g|x = g|x0 + dkggr(x) * ( (g-r)|x0 - (g-r)BD+17|x_0 ) ... z|x = z|x0 + dkziz(x) * ( (i-z)|x0 - (i-z)BD+17|x_0 ) where the dk(x) are (position dependant) color terms. We provide dk(x) maps for each MegaCam band (see below). The SNLS 3 year calibration relies on the (Landolt, 1992AJ....104..340) standard star catalog. Landolt fields are observed during each photometric night along with the SNLS fields. Zero-points are derived from these observations. Stable and isolated stars are detected on the SNLS fields and selected as "tertiary standards". The calibrated magnitudes of each tertiary standard obtained under photometric conditions are combined to produce a calibration catalog for each SNLS field. To interpret the tertiary standard magnitudes as physical fluxes, we need a primary standard, i.e. a star with known MegaCam magnitudes and whose spectral energy distribution has been measured absolutely. The SNLS uses BD+17 4708 whose SED has been measured in Bohlin & Gilliland, 2004, Cat.
48 CFR 836.602-2 - Evaluation boards.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Management projects. The Director, Office of Construction and Facilities Management, shall appoint an... appropriate for the particular project. The Director, Office of Construction and Facilities Management may... Evaluation boards. (a) The Director, Office of Construction and Facilities Management, shall appoint an...
ERIC Educational Resources Information Center
Council of Educational Facility Planners, International, Scottsdale, AZ.
A team of 11 educational facility planners and architects from the United States and Canada conducted a facility evaluation of schools in the rural areas of Meambar and Cortes, Honduras. Team members were all part of the Council of Educational Facility Planners, International and traveled to Honduras under the auspices of a Christian mission…
NASA Astrophysics Data System (ADS)
Sutanto, G. R.; Kim, S.; Kim, D.; Sutanto, H.
2018-03-01
One of the problems in dealing with capacitated facility location problem (CFLP) is occurred because of the difference between the capacity numbers of facilities and the number of customers that needs to be served. A facility with small capacity may result in uncovered customers. These customers need to be re-allocated to another facility that still has available capacity. Therefore, an approach is proposed to handle CFLP by using k-means clustering algorithm to handle customers’ allocation. And then, if customers’ re-allocation is needed, is decided by the overall average distance between customers and the facilities. This new approach is benchmarked to the existing approach by Liao and Guo which also use k-means clustering algorithm as a base idea to decide the facilities location and customers’ allocation. Both of these approaches are benchmarked by using three clustering evaluation methods with connectedness, compactness, and separations factors.
Natural phenomena hazards design and evaluation criteria for Department of Energy Facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-01-01
The Department of Energy (DOE) has issued an Order 420.1 which establishes policy for its facilities in the event of natural phenomena hazards (NPH) along with associated NPH mitigation requirements. This DOE Standard gives design and evaluation criteria for NPH effects as guidance for implementing the NPH mitigation requirements of DOE Order 420.1 and the associated implementation Guides. These are intended to be consistent design and evaluation criteria for protection against natural phenomena hazards at DOE sites throughout the United States. The goal of these criteria is to assure that DOE facilities can withstand the effects of natural phenomena suchmore » as earthquakes, extreme winds, tornadoes, and flooding. These criteria apply to the design of new facilities and the evaluation of existing facilities. They may also be used for modification and upgrading of existing facilities as appropriate. The design and evaluation criteria presented herein control the level of conservatism introduced in the design/evaluation process such that earthquake, wind, and flood hazards are treated on a consistent basis. These criteria also employ a graded approach to ensure that the level of conservatism and rigor in design/evaluation is appropriate for facility characteristics such as importance, hazards to people on and off site, and threat to the environment. For each natural phenomena hazard covered, these criteria consist of the following: Performance Categories and target performance goals as specified in the DOE Order 420.1 NPH Implementation Guide, and DOE-STD-1 021; specified probability levels from which natural phenomena hazard loading on structures, equipment, and systems is developed; and design and evaluation procedures to evaluate response to NPH loads and criteria to assess whether or not computed response is permissible.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This removal site evaluation (RmSE) report of the Isotope Facilities at Oak Ridge National Laboratory (ORNL) was prepared to provide the Environmental Restoration Program with information necessary to evaluate whether hazardous and/or radiological contaminants in and around the Isotopes Facility pose a substantial risk to human health or the environment and if remedial site evaluations (RSEs) or removal actions are required. The scope of the project included: (1) a review of historical evidence regarding operations and use of the facility; (2) interviews with facility personnel concerning current and past operating practices; (3) a site inspection; and (4) identification of hazardmore » areas requiring maintenance, removal, or remedial actions. The results of RmSE indicate that no substantial risks exist from contaminants present in the Isotope Facilities because adequate controls and practices exist to protect human health and the environment. The recommended correction from the RmSE are being conducted as maintenance actions; accordingly, this RmSE is considered complete and terminated.« less
Apollo experience report: Real-time auxiliary computing facility development
NASA Technical Reports Server (NTRS)
Allday, C. E.
1972-01-01
The Apollo real time auxiliary computing function and facility were an extension of the facility used during the Gemini Program. The facility was expanded to include support of all areas of flight control, and computer programs were developed for mission and mission-simulation support. The scope of the function was expanded to include prime mission support functions in addition to engineering evaluations, and the facility became a mandatory mission support facility. The facility functioned as a full scale mission support activity until after the first manned lunar landing mission. After the Apollo 11 mission, the function and facility gradually reverted to a nonmandatory, offline, on-call operation because the real time program flexibility was increased and verified sufficiently to eliminate the need for redundant computations. The evaluation of the facility and function and recommendations for future programs are discussed in this report.
Emerson, C; Lipke, V; Kapata, N; Mwananyambe, N; Mwinga, A; Garekwe, M; Lanje, S; Moshe, Y; Pals, S L; Nakashima, A K; Miller, B
2016-07-01
Out-patient human immunodeficiency virus (HIV) care and treatment clinics in Zambia and Botswana, countries with a high burden of HIV and TB infection. To develop a tuberculosis infection control (TB IC) training and implementation package and evaluate the implementation of TB IC activities in facilities implementing the package. Prospective program evaluation of a TB IC training and implementation package using a standardized facility risk assessment tool, qualitative interviews with facility health care workers and measures of pre- and post-test performance. A composite measure of facility performance in TB IC improved from 32% at baseline to 50% at 1 year among eight facilities in Zambia, and from 27% to 80% at 6 months among 10 facilities in Botswana. Although there was marked improvement in indicators of managerial, administrative and environmental controls, key ongoing challenges remained in ensuring access to personal protective equipment and implementing TB screening in health care workers. TB IC activities at out-patient HIV clinics in Zambia and Botswana improved after training using the implementation package. Continued infrastructure support, as well as monitoring and evaluation, are needed to support the scale-up and sustainability of TB IC programs in facilities in low-resource countries.
2012-06-16
Engineers to help identify and develop energy and water conservation projects in the facilities for which they are responsible. DISCLAIMER: The...and water throughout their facility. To identify energy and water conservation measures (ECMs), an energy manager would generally start by performing...an Energy and Water Conservation Assessment, essentially a facility-level evaluation of the en- ergy and water consuming equipment and systems that
A model for evaluating the environmental benefits of elementary school facilities.
Ji, Changyoon; Hong, Taehoon; Jeong, Kwangbok; Leigh, Seung-Bok
2014-01-01
In this study, a model that is capable of evaluating the environmental benefits of a new elementary school facility was developed. The model is composed of three steps: (i) retrieval of elementary school facilities having similar characteristics as the new elementary school facility using case-based reasoning; (ii) creation of energy consumption and material data for the benchmark elementary school facility using the retrieved similar elementary school facilities; and (iii) evaluation of the environmental benefits of the new elementary school facility by assessing and comparing the environmental impact of the new and created benchmark elementary school facility using life cycle assessment. The developed model can present the environmental benefits of a new elementary school facility in terms of monetary values using Environmental Priority Strategy 2000, a damage-oriented life cycle impact assessment method. The developed model can be used for the following: (i) as criteria for a green-building rating system; (ii) as criteria for setting the support plan and size, such as the government's incentives for promoting green-building projects; and (iii) as criteria for determining the feasibility of green building projects in key business sectors. Copyright © 2013 Elsevier Ltd. All rights reserved.
Improving the explanation capabilities of advisory systems
NASA Technical Reports Server (NTRS)
Porter, Bruce; Souther, Art
1993-01-01
A major limitation of current advisory systems (e.g., intelligent tutoring systems and expert systems) is their restricted ability to give explanations. The goal of our research is to develop and evaluate a flexible explanation facility, one that can dynamically generate responses to questions not anticipated by the system's designers and that can tailor these responses to individual users. To achieve this flexibility, we are developing a large knowledge base, a viewpoint construction facility, and a modeling facility. In the long term we plan to build and evaluate advisory systems with flexible explanation facilities for scientists in numerous domains. In the short term, we are focusing on a single complex domain in biological science, and we are working toward two important milestones: (1) building and evaluating an advisory system with a flexible explanation facility for freshman-level students studying biology; and (2) developing general methods and tools for building similar explanation facilities in other domains.
Improving the explanation capabilities of advisory systems
NASA Technical Reports Server (NTRS)
Porter, Bruce; Souther, Art
1994-01-01
A major limitation of current advisory systems (e.g., intelligent tutoring systems and expert systems) is their restricted ability to give explanations. The goal of our research is to develop and evaluate a flexible explanation facility, one that can dynamically generate responses to questions not anticipated by the system's designers and that can tailor these responses to individual users. To achieve this flexibility, we are developing a large knowledge base, a viewpoint construction facility, and a modeling facility. In the long term we plan to build and evaluate advisory systems with flexible explanation facilities for scientists in numerous domains. In the short term, we are focusing on a single complex domain in biological science, and we are working toward two important milestones: (1) building and evaluating an advisory system with a flexible explanation facility for freshman-level students studying biology, and (2) developing general methods and tools for building similar explanation facilities in other domains.
Goldman, L Elizabeth; Walker, Rod; Hubbard, Rebecca; Kerlikowske, Karla
2013-04-01
Whether timeliness of follow-up after abnormal mammography differs at facilities serving vulnerable populations, such as women with limited education or income, in rural areas, and racial/ethnic minorities is unknown. We examined receipt of diagnostic evaluation after abnormal mammography using 1998-2006 Breast Cancer Surveillance Consortium-linked Medicare claims. We compared whether time to recommended breast imaging or biopsy depended on whether women attended facilities serving vulnerable populations. We characterized a facility by the proportion of mammograms performed on women with limited education or income, in rural areas, or racial/ethnic minorities. We analyzed 30,874 abnormal screening examinations recommended for follow-up imaging across 142 facilities and 10,049 abnormal diagnostic examinations recommended for biopsy across 114 facilities. Women at facilities serving populations with less education or more racial/ethnic minorities had lower rates of follow-up imaging (4%-5% difference, P<0.05), and women at facilities serving more rural and low-income populations had lower rates of biopsy (4%-5% difference, P<0.05). Women undergoing biopsy at facilities serving vulnerable populations had longer times until biopsy than those at facilities serving nonvulnerable populations (21.6 vs. 15.6 d; 95% confidence interval for mean difference 4.1-7.7). The proportion of women receiving recommended imaging within 11 months and biopsy within 3 months varied across facilities (interquartile range, 85.5%-96.5% for imaging and 79.4%-87.3% for biopsy). Among Medicare recipients, follow-up rates were slightly lower at facilities serving vulnerable populations, and among those women who returned for diagnostic evaluation, time to follow-up was slightly longer at facilities that served vulnerable population. Interventions should target variability in follow-up rates across facilities, and evaluate effectiveness particularly at facilities serving vulnerable populations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lindsey, C. T.; Gano, K. A.; Lucas, J. G.
The 183-D Water Filtration Facility is located in the 100-D Area of the Hanford Site, north of Richland, Washington. It was used to provide filtered water for cooling the 105-D Reactor and supplying fire-protection and drinking water for all facilities in the 100-D Area. The facility has been inactive since the 1980s and is now scheduled for demolition. Therefore, an evaluation was conducted to determine if any part of the facility was being used as roosting habitat by bats.
Muller, George; Perkins, Casey J.; Lancaster, Mary J.; MacDonald, Douglas G.; Clements, Samuel L.; Hutton, William J.; Patrick, Scott W.; Key, Bradley Robert
2015-07-28
Computer-implemented security evaluation methods, security evaluation systems, and articles of manufacture are described. According to one aspect, a computer-implemented security evaluation method includes accessing information regarding a physical architecture and a cyber architecture of a facility, building a model of the facility comprising a plurality of physical areas of the physical architecture, a plurality of cyber areas of the cyber architecture, and a plurality of pathways between the physical areas and the cyber areas, identifying a target within the facility, executing the model a plurality of times to simulate a plurality of attacks against the target by an adversary traversing at least one of the areas in the physical domain and at least one of the areas in the cyber domain, and using results of the executing, providing information regarding a security risk of the facility with respect to the target.
NASA Technical Reports Server (NTRS)
Rogers, J. P.; Cureton, K. L.; Olsen, J. R.
1994-01-01
Future aerospace vehicles will require use of the Electrical Actuator systems for flight control elements. This report presents a proposed ELA Test Facility for dynamic evaluation of high power linear Electrical Actuators with primary emphasis on Thrust Vector Control actuators. Details of the mechanical design, power and control systems, and data acquisition capability of the test facility are presented. A test procedure for evaluating the performance of the ELA Test Facility is also included.
Fads, Fancies and Fantasies: An Educator's Perspective on Current Educational Facility Issues.
ERIC Educational Resources Information Center
Ryland, James
2003-01-01
Explores educational facilities issues from the personal perspective of being both an educator and an owner. Topics discussed include aligning curriculum and instruction with facilities design, green school rating systems, the relationship between facilities and achievement, longitudinal facilities research, post-occupancy evaluation, and…
Sea Level Operation Demonstration of F404-GE-400 Turbofan Engine with JP-5/Bio-Fuel Mixture
2010-03-30
Aircraft Test and Evaluation Facility Hush House at Naval Air Station Patuxent River, Maryland, on 13 October 2009. The test consisted of two separate...turbofan engine inside the Aircraft Test and Evaluation Facility Hush House at Naval Air Station Patuxent River, Maryland, on 13 October 2009. The test...turbofan engine (ESN 310810) inside the Aircraft Test and Evaluation Facility Hush House at Naval Air Station (NAS) Patuxent River, Maryland, on 13
This report documents an evaluation of the environmental, economic, and energy impacts of material recovery facilities (MRFS) conducted under the Municipal Solid Waste Innovative Technology Evaluation (MITE) Program. he MITE Program is sponsored by the U.S. Environmental Protecti...
Materials and Nondestructive Evaluation Laboratoriers: User Test Planning Guide
NASA Technical Reports Server (NTRS)
Schaschl, Leslie
2011-01-01
The Materials and Nondestructive Evaluation Laboratory process, milestones and inputs are unknowns to first-time users. The Materials and Nondestructive Evaluation Laboratory Planning Guide aids in establishing expectations for both NASA and non- NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware developers. It is intended to assist their project engineering personnel in materials analysis planning and execution. Material covered includes a roadmap of the analysis process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, products, and inputs necessary to define scope of analysis, cost, and schedule are included as an appendix to the guide.
Summary of findings from the evaluation of a pilot medically supervised safer injecting facility
Wood, Evan; Tyndall, Mark W.; Montaner, Julio S.; Kerr, Thomas
2006-01-01
In many cities, infectious disease and overdose epidemics are occurring among illicit injection drug users (IDUs). To reduce these concerns, Vancouver opened a supervised safer injecting facility in September 2003. Within the facility, people inject pre-obtained illicit drugs under the supervision of medical staff. The program was granted a legal exemption by the Canadian government on the condition that a 3-year scientific evaluation of its impacts be conducted. In this review, we summarize the findings from evaluations in those 3 years, including characteristics of IDUs at the facility, public injection drug use and publicly discarded syringes, HIV risk behaviour, use of addiction treatment services and other community resources, and drug-related crime rates. Vancouver's safer injecting facility has been associated with an array of community and public health benefits without evidence of adverse impacts. These findings should be useful to other cities considering supervised injecting facilities and to governments considering regulating their use. PMID:17116909
Code of Federal Regulations, 2011 CFR
2011-07-01
... evaluation criteria for facilities that handle, store, or transport Group V petroleum oils. 154.1047 Section... Group V petroleum oils. (a) An owner or operator of a facility that handles, stores, or transports Group...) Procedures and strategies for responding to a worst case discharge of Group V petroleum oils to the maximum...
Code of Federal Regulations, 2013 CFR
2013-07-01
... evaluation criteria for facilities that handle, store, or transport Group V petroleum oils. 154.1047 Section... Group V petroleum oils. (a) An owner or operator of a facility that handles, stores, or transports Group...) Procedures and strategies for responding to a worst case discharge of Group V petroleum oils to the maximum...
Code of Federal Regulations, 2010 CFR
2010-07-01
... evaluation criteria for facilities that handle, store, or transport Group V petroleum oils. 154.1047 Section... Group V petroleum oils. (a) An owner or operator of a facility that handles, stores, or transports Group...) Procedures and strategies for responding to a worst case discharge of Group V petroleum oils to the maximum...
Code of Federal Regulations, 2014 CFR
2014-07-01
... evaluation criteria for facilities that handle, store, or transport Group V petroleum oils. 154.1047 Section... Group V petroleum oils. (a) An owner or operator of a facility that handles, stores, or transports Group...) Procedures and strategies for responding to a worst case discharge of Group V petroleum oils to the maximum...
Code of Federal Regulations, 2012 CFR
2012-07-01
... evaluation criteria for facilities that handle, store, or transport Group V petroleum oils. 154.1047 Section... Group V petroleum oils. (a) An owner or operator of a facility that handles, stores, or transports Group...) Procedures and strategies for responding to a worst case discharge of Group V petroleum oils to the maximum...
Evaluation of intermodal passenger transfer facilities
DOT National Transportation Integrated Search
1994-09-01
The Wisconsin Department of Transportation has initiated a study into the feasibility of locating an intermodal passenger transportation facility in downtown Milwaukee. That feasibilty study requires an evaluation of a very wide range of alternatives...
NASA Technical Reports Server (NTRS)
Tavana, Madjid
2005-01-01
"To understand and protect our home planet, to explore the universe and search for life, and to inspire the next generation of explorers" is NASA's mission. The Systems Management Office at Johnson Space Center (JSC) is searching for methods to effectively manage the Center's resources to meet NASA's mission. D-Side is a group multi-criteria decision support system (GMDSS) developed to support facility decisions at JSC. D-Side uses a series of sequential and structured processes to plot facilities in a three-dimensional (3-D) graph on the basis of each facility alignment with NASA's mission and goals, the extent to which other facilities are dependent on the facility, and the dollar value of capital investments that have been postponed at the facility relative to the facility replacement value. A similarity factor rank orders facilities based on their Euclidean distance from Ideal and Nadir points. These similarity factors are then used to allocate capital improvement resources across facilities. We also present a parallel model that can be used to support decisions concerning allocation of human resources investments across workforce units. Finally, we present results from a pilot study where 12 experienced facility managers from NASA used D-Side and the organization's current approach to rank order and allocate funds for capital improvement across 20 facilities. Users evaluated D-Side favorably in terms of ease of use, the quality of the decision-making process, decision quality, and overall value-added. Their evaluations of D-Side were significantly more favorable than their evaluations of the current approach. Keywords: NASA, Multi-Criteria Decision Making, Decision Support System, AHP, Euclidean Distance, 3-D Modeling, Facility Planning, Workforce Planning.
NASA Astrophysics Data System (ADS)
Kowalski, John B.; Herring, Craig; Baryschpolec, Lisa; Reger, John; Patel, Jay; Feeney, Mary; Tallentire, Alan
2002-08-01
The International and European standards for radiation sterilization require evidence of the effectiveness of a minimum sterilization dose of 25 kGy but do not provide detailed guidance on how this evidence can be generated. An approach, designated VD max, has recently been described and computer evaluated to provide safe and unambiguous substantiation of a 25 kGy sterilization dose. The approach has been further developed into a practical method, which has been subjected to field evaluations at three manufacturing facilities which produce different types of medical devices. The three facilities each used a different overall evaluation strategy: Facility A used VD max for quarterly dose audits; Facility B compared VD max and Method 1 in side-by-side parallel experiments; and Facility C, a new facility at start-up, used VD max for initial substantiation of 25 kGy and subsequent quarterly dose audits. A common element at all three facilities was the use of 10 product units for irradiation in the verification dose experiment. The field evaluations of the VD max method were successful at all three facilities; they included many different types of medical devices/product families with a wide range of average bioburden and sample item portion values used in the verification dose experiments. Overall, around 500 verification dose experiments were performed and no failures were observed. In the side-by-side parallel experiments, the outcomes of the VD max experiments were consistent with the outcomes observed with Method 1. The VD max approach has been extended to sterilization doses >25 and <25 kGy; verification doses have been derived for sterilization doses of 15, 20, 30, and 35 kGy. Widespread application of the VD max method for doses other than 25 kGy must await controlled field evaluations and the development of appropriate specifications/standards.
A Manual for Evaluating School Facilities.
ERIC Educational Resources Information Center
Reida, G.W.
This survey manual evaluates the important points of functionality of school facilities in logical order. Instructions are given for the use of the manual, and separate sections present guidelines for evaluation of the following--(1) site, (2) building structure, (3) administrative spaces, (4) classrooms, (5) special rooms, (6) general service…
Urban Watershed Research Facility at Edison Environmental Center
The Urban Watershed Research Facility (UWRF) is an isolated, 20-acre open space within EPA’s 200 acre Edison facility established to develop and evaluate the performance of stormwater management practices under controlled conditions. The facility includes greenhouses that allow ...
Aeronautical facilities assessment
NASA Technical Reports Server (NTRS)
Penaranda, F. E. (Compiler)
1985-01-01
A survey of the free world's aeronautical facilities was undertaken and an evaluation made on where the relative strengths and weaknesses exist. Special emphasis is given to NASA's own capabilities and needs. The types of facilities surveyed are: Wind Tunnels; Airbreathing Propulsion Facilities; and Flight Simulators
ERIC Educational Resources Information Center
Teicholz, Eric
1997-01-01
Reports research on trends in computer-aided facilities management using the Internet and geographic information system (GIS) technology for space utilization research. Proposes that facility assessment software holds promise for supporting facility management decision making, and outlines four areas for its use: inventory; evaluation; reporting;…
Meyer, P.D.; Rockhold, M.L.; Nichols, W.E.; Gee, G.W.
1996-01-01
This report identifies key technical issues related to hydrologic assessment of water flow in the unsaturated zone at low-level radioactive waste (LLW) disposal facilities. In addition, a methodology for incorporating these issues in the performance assessment of proposed LLW disposal facilities is identified and evaluated. The issues discussed fall into four areas:Estimating the water balance at a site (i.e., infiltration, runoff, water storage, evapotranspiration, and recharge);Analyzing the hydrologic performance of engineered components of a facility;Evaluating the application of models to the prediction of facility performance; andEstimating the uncertainty in predicted facility performance.An estimate of recharge at a LLW site is important since recharge is a principal factor in controlling the release of contaminants via the groundwater pathway. The most common methods for estimating recharge are discussed in Chapter 2. Many factors affect recharge; the natural recharge at an undisturbed site is not necessarily representative either of the recharge that will occur after the site has been disturbed or of the flow of water into a disposal facility at the site. Factors affecting recharge are discussed in Chapter 2.At many sites engineered components are required for a LLW facility to meet performance requirements. Chapter 3 discusses the use of engineered barriers to control the flow of water in a LLW facility, with a particular emphasis on cover systems. Design options and the potential performance and degradation mechanisms of engineered components are also discussed.Water flow in a LLW disposal facility must be evaluated before construction of the facility. In addition, hydrologic performance must be predicted over a very long time frame. For these reasons, the hydrologic evaluation relies on the use of predictive modeling. In Chapter 4, the evaluation of unsaturated water flow modeling is discussed. A checklist of items is presented to guide the evaluation. Several computer simulation codes that were used in the examples (Chapter 6) are discussed with respect to this checklist. The codes used include HELP, UNSAT-H, and VAM3DCG.To provide a defensible estimate of water flow in a LLW disposal facility, the uncertainty associated with model predictions must be considered. Uncertainty arises because of the highly heterogeneous nature of most subsurface environments and the long time frame required in the analysis. Sources of uncertainty in hydrologic evaluation of the unsaturated zone and several approaches for analysis are discussed in Chapter 5. The methods of analysis discussed include a bounding approach, sensitivity analysis, and Monte Carlo simulation.To illustrate the application of the discussion in Chapters 2 through 5, two examples are presented in Chapter 6. The first example is of a below ground vault located in a humid environment. The second example looks at a shallow land burial facility located in an arid environment. The examples utilize actual site-specific data and realistic facility designs. The two examples illustrate the issues unique to humid and arid sites as well as the issues common to all LLW sites. Strategies for addressing the analytical difficulties arising in any complex hydrologic evaluation of the unsaturated zone are demonstrated.The report concludes with some final observations and recommendations.
Goldman, L. Elizabeth; Walker, Rod; Hubbard, Rebecca; Kerlikowske, Karla
2013-01-01
Background Whether timeliness of follow-up after abnormal mammography differs at facilities serving vulnerable populations such as women with limited education or income, in rural areas, and racial/ethnic minorities is unknown. Methods We examined receipt of diagnostic evaluation following abnormal mammography using 1998-2006 Breast Cancer Surveillance Consortium-linked Medicare claims. We compared whether time to recommended breast imaging or biopsy depended on whether women attended facilities serving vulnerable populations. We characterized a facility by the proportion of mammograms performed on women with limited education or income, in rural areas, or racial/ethnic minorities. Results We analyzed 30,874 abnormal screening examinations recommended for follow-up imaging across 142 facilities and 10,049 abnormal diagnostic examinations recommended for biopsy across 114 facilities. Women at facilities serving populations with less education or more racial/ethnic minorities had lower rates of follow-up imaging (4-5% difference, p<0.05), and women at facilities serving more rural and low income populations had lower rates of biopsy (4-5% difference, p<0.05). Women undergoing biopsy at facilities serving vulnerable populations had longer times until biopsy than those at facilities serving non-vulnerable populations (21.6 days vs. 15.6 days; 95% CI for mean difference 4.1-7.7). The proportion of women receiving recommended imaging within 11 months and biopsy within 3 months varied across facilities (interquartile range 85.5%-96.5% for imaging and 79.4%-87.3% for biopsy). Conclusions Among Medicare recipients, follow-up rates were slightly lower at facilities serving vulnerable populations, and among those women who returned for diagnostic evaluation, time to follow-up was slightly longer at facilities that served vulnerable population. Interventions should target variability in follow-up rates across facilities, and evaluate effectiveness particularly at facilities serving vulnerable populations. PMID:23358386
Methods for evaluating temporal trends in noise exposure
Neitzel, RL; Galusha, D; Dixon-Ernst, C; Rabinowitz, PM
2014-01-01
Objective Hearing conservation programs have been mandatory in many US industries since 1983. Since then, three program elements (audiometric testing, hearing protection, and training) have been the focus of much research. By comparison, little has been done on noise exposure evaluation. Design and study sample Utilizing a large dataset (>10,000 measurements over 20 years) from eight facilities operated by a multinational aluminum manufacturing company, we evaluated several approaches to assessing temporal trends in Time Weighted Average (TWA) exposures and the fraction of measurements exceeding 85 dBA by facility, by exposure group within facility, and by individual worker within facility. Results Overall, exposures declined across locations over the study period. Several facilities demonstrated substantial reductions in exposure, and the results of mean noise levels and exceedance fractions generally showed good agreement. The results of analyses at the individual level diverged with analyses by facility and exposure group within facility, suggesting that individual-level analyses, while challenging, may provide important information not available from coarser levels of analysis. Conclusions Validated metrics are needed to allow for assessment of temporal trends in noise exposure. Such metrics will improve our ability to characterize, in a standardized manner, efforts to reduce noise-induced hearing loss. PMID:24564696
Methods for evaluating temporal trends in noise exposure.
Neitzel, R L; Galusha, D; Dixon-Ernst, C; Rabinowitz, P M
2014-03-01
Hearing conservation programs have been mandatory in many US industries since 1983. Since then, three program elements (audiometric testing, hearing protection, and training) have been the focus of much research. By comparison, little has been done on noise exposure evaluation. Temporal trends in time weighted average (TWA) exposures and the fraction of measurements exceeding 85 dBA were evaluated by facility, by exposure group within facility, and by individual worker within facility. A large dataset (> 10 000 measurements over 20 years) from eight facilities operated by a multinational aluminum manufacturing company was studied. Overall, exposures declined across locations over the study period. Several facilities demonstrated substantial reductions in exposure, and the results of mean noise levels and exceedance fractions generally showed good agreement. The results of analyses at the individual level diverged with analyses by facility and exposure group within facility, suggesting that individual-level analyses, while challenging, may provide important information not available from coarser levels of analysis. Validated metrics are needed to allow for assessment of temporal trends in noise exposure. Such metrics will improve our ability to characterize, in a standardized manner, efforts to reduce noise-induced hearing loss.
Flat panel display test and evaluation: procedures, standards, and facilities
NASA Astrophysics Data System (ADS)
Jackson, Timothy W.; Daniels, Reginald; Hopper, Darrel G.
1997-07-01
This paper addresses flat panel display test and evaluation via a discussion of procedures, standards and facilities. Procedures need to be carefully developed and documented to ensure that test accomplished in separate laboratories produce comparable results. The tests themselves must not be a source of inconsistency in test results when such comparisons are made in the course of procurements or new technology prototype evaluations. Standards are necessary to expedite the transition of the new display technologies into applications and to lower the costs of custom parts applied across disparate applications. The flat panel display industry is in the course of ascertaining and formulating such standards as they are of value to designers, manufacturers, marketers and users of civil and military products and equipment. Additionally, in order to inform the DoD and industry, the test and evaluation facilities of the Air Force Research Laboratory Displays Branch are described. These facilities are available to support procurements involving flat panel displays and to examine new technology prototypes. Finally, other government display testing facilities within the Navy and the Army are described.
Evaluation of high-voltage, high-power, solid-state remote power controllers for amps
NASA Technical Reports Server (NTRS)
Callis, Charles P.
1987-01-01
The Electrical Power Branch at Marshall Space Flight Center has a Power System Development Facility where various power circuit breadboards are tested and evaluated. This project relates to the evaluation of a particular remote power controller (RPC) energizing high power loads. The Facility equipment permits the thorough testing and evaluation of high-voltage, high-power solid-state remote power controllers. The purpose is to evaluate a Type E, 30 Ampere, 200 V dc remote power controller. Three phases of the RPC evaluation are presented. The RPC is evaluated within a low-voltage, low-power circuit to check its operational capability. The RPC is then evaluated while performing switch/circuit breaker functions within a 200 V dc, 30 Ampere power circuit. The final effort of the project relates to the recommended procedures for installing these RPC's into the existing Autonomously Managed Power System (AMPS) breadboard/test facility at MSFC.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-20
... the ``Regulatory Guides'' collection of the NRC's Library at http://www.nrc.gov/reading-rm/doc... NUCLEAR REGULATORY COMMISSION [NRC-2011-0152] Evaluations of Explosions Postulated To Occur at..., ``Evaluations of Explosions Postulated to Occur at Nearby Facilities and on Transportation Routes Near Nuclear...
Evaluating building performance in healthcare facilities: an organizational perspective.
Steinke, Claudia; Webster, Lynn; Fontaine, Marie
2010-01-01
Using the environment as a strategic tool is one of the most cost-effective and enduring approaches for improving public health; however, it is one that requires multiple perspectives. The purpose of this article is to highlight an innovative methodology that has been developed for conducting comprehensive performance evaluations in public sector health facilities in Canada. The building performance evaluation methodology described in this paper is a government initiative. The project team developed a comprehensive building evaluation process for all new capital health projects that would respond to the aforementioned need for stakeholders to be more accountable and to better integrate the larger organizational strategy of facilities. The Balanced Scorecard, which is a multiparadigmatic, performance-based business framework, serves as the underlying theoretical framework for this initiative. It was applied in the development of the conceptual model entitled the Building Performance Evaluation Scorecard, which provides the following benefits: (1) It illustrates a process to link facilities more effectively to the overall mission and goals of an organization; (2) It is both a measurement and a management system that has the ability to link regional facilities to measures of success and larger business goals; (3) It provides a standardized methodology that ensures consistency in assessing building performance; and (4) It is more comprehensive than traditional building evaluations. The methodology presented in this paper is both a measurement and management system that integrates the principles of evidence-based design with the practices of pre- and post-occupancy evaluation. It promotes accountability and continues throughout the life cycle of a project. The advantage of applying this framework is that it engages health organizations in clarifying a vision and strategy for their facilities and helps translate those strategies into action and measurable performance outcomes.
Systematic Planning for Educational Facilities.
ERIC Educational Resources Information Center
McGuffey, Carroll W.
This monograph provides a systematic approach to the problem of planning educational facilities. It first presents a conceptual framework for a general facilities planning and management system called Facilities Resource Allocation Management Evaluation System (FRAMES). The main components of FRAMES are identified as: (1) needs assessment, (2)…
Particulate matter adjacent to cattle deep-bedded monoslope facilities
USDA-ARS?s Scientific Manuscript database
Purpose: Confined cattle facilities are an increasingly common housing system in the Northern Great Plains region. Many of these facilities add organic bedding material to the pens once or twice per week. Particulate matter concentrations and emissions from these facilities have not been evaluate...
ERIC Educational Resources Information Center
Erickson, Paul W.
2009-01-01
Long-range facility planning is a comprehensive process for preparing education institutions for the future and confirm that facilities meet current needs. A long-range facilities plan (LRFP) evaluates how facilities support programs and the educational needs of students, staff and the community. Each school district or college has unique needs…
Floor vibration evaluations for medical facilities
NASA Astrophysics Data System (ADS)
Himmel, Chad N.
2003-10-01
The structural floor design for new medical facilities is often selected early in the design phase and in renovation projects, the floor structure already exists. Because the floor structure can often have an influence on the location of vibration sensitive medical equipment and facilities, it is becoming necessary to identify the best locations for equipment and facilities early in the design process. Even though specific criteria for vibration-sensitive uses and equipment may not always be available early in the design phase, it should be possible to determine compatible floor structures for planned vibration-sensitive uses by comparing conceptual layouts with generic floor vibration criteria. Relatively simple evaluations of planned uses and generic criteria, combined with on-site vibration and noise measurements early in design phase, can significantly reduce future design problems and expense. Concepts of evaluation procedures and analyses will be presented in this paper. Generic floor vibration criteria and appropriate parameters to control resonant floor vibration and noise will be discussed for typical medical facilities and medical research facilities. Physical, economic, and logistical limitations that affect implementation will be discussed through case studies.
Northeast Oregon Hatchery Project, Final Siting Report.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watson, Montgomery
1995-03-01
This report presents the results of site analysis for the Bonneville Power Administration Northeast Oregon Hatchery Project. The purpose of this project is to provide engineering services for the siting and conceptual design of hatchery facilities for the Bonneville Power Administration. The hatchery project consists of artificial production facilities for salmon and steelhead to enhance production in three adjacent tributaries to the Columbia River in northeast Oregon: the Grande Ronde, Walla Walla, and Imnaha River drainage basins. Facilities identified in the master plan include adult capture and holding facilities; spawning incubation, and early rearing facilities; full-term rearing facilities; and directmore » release or acclimation facilities. The evaluation includes consideration of a main production facility for one or more of the basins or several smaller satellite production facilities to be located within major subbasins. The historic and current distribution of spring and fall chinook salmon and steelhead was summarized for the Columbia River tributaries. Current and future production and release objectives were reviewed. Among the three tributaries, forty seven sites were evaluated and compared to facility requirements for water and space. Site screening was conducted to identify the sites with the most potential for facility development. Alternative sites were selected for conceptual design of each facility type. A proposed program for adult holding facilities, final rearing/acclimation, and direct release facilities was developed.« less
Hanford Site Asbestos Abatement Plan. Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mewes, B.S.
The Hanford Site Asbestos Abatement Plan (Plan) lists priorities for asbestos abatement activities to be conducted in Hanford Site facilities. The Plan is based on asbestos assessment information gathered in fiscal year 1989 that evaluated all Hanford Site facilities for the presence and condition of asbestos. Of those facilities evaluated, 414 contain asbestos-containing materials and are classified according to the potential risk of asbestos exposure to building personnel. The Plan requires that asbestos condition update reports be prepared for all affected facilities. The reporting is completed by the asbestos coordinator for each of the 414 affected facilities and transmitted tomore » the Plan manager annually. The Plan manager uses this information to reprioritize future project lists. Currently, five facilities are determined to be Class Al, indicating a high potential for asbestos exposure. Class Al and B1 facilities are the highest priority for asbestos abatement. Abatement of the Class A1 and Bl facilities is scheduled through fiscal year 1997. Removal of asbestos in B1 facilities will reduce the risk for further Class ``A`` conditions to arise.« less
NASA Technical Reports Server (NTRS)
Kerczewski, Robert J.; Ivancic, William D.; Zuzek, John E.
1991-01-01
The development of new space communications technologies by NASA has included both commercial applications and space science requirements. At NASA's Lewis Research Center, methods and facilities have been developed for evaluating these new technologies in the laboratory. NASA's Systems Integration, Test and Evaluation (SITE) Space Communication System Simulator is a hardware-based laboratory simulator for evaluating space communications technologies at the component, subsystem, system, and network level, geared toward high frequency, high data rate systems. The SITE facility is well-suited for evaluation of the new technologies required for the Space Exploration Initiative (SEI) and advanced commercial systems. This paper describes the technology developments and evaluation requirements for current and planned commercial and space science programs. Also examined are the capabilities of SITE, the past, present, and planned future configurations of the SITE facility, and applications of SITE to evaluation of SEI technology.
Evaluation of Facility Management by Multivariate Statistics - Factor Analysis
NASA Astrophysics Data System (ADS)
Singovszki, Miloš; Vranayová, Zuzana
2013-06-01
Facility management is evolving, there is no exact than other sciences, although its development is fast forward. The knowledge and practical skills in facility management is not replaced, on the contrary, they complement each other. The existing low utilization of science in the field of facility management is mainly caused by the management of support activities are many variables and prevailing immediate reaction to the extraordinary situation arising from motives of those who have substantial experience and years of proven experience. Facility management is looking for a system that uses organized knowledge and will form the basis, which grows from a wide range of disciplines. Significant influence on its formation as a scientific discipline is the "structure, which follows strategy". The paper deals evaluate technology building as part of an facility management by multivariate statistic - factor analysis.
DOT National Transportation Integrated Search
2012-02-01
One of the most important tasks in maintaining transportation facilities such as highways : and streets is the evaluation of the existing condition. Visual evaluation by human : inspectors is subjective in nature, therefore has issues of consistency ...
DOT National Transportation Integrated Search
2008-03-01
The main objective of this study was to determine the most beneficial and cost-effective accelerated load facility that can be used in conjunction with LTRCs Accelerated Load Facility (ALF). The facility will be used primarily for conducting preli...
Vehicle Thermal Management Facilities | Transportation Research | NREL
Management Facilities Vehicle Thermal Management Facilities Image of a building with two semi truck evaluation facilities to develop advanced thermal management technologies for vehicles. Vehicle Testing and apparatus. Combined fluid loops bench research apparatus in the Vehicle Thermal Management Laboratory. Photo
Hise, Adam M; Characklis, Gregory W; Kern, Jordan; Gerlach, Robin; Viamajala, Sridhar; Gardner, Robert D; Vadlamani, Agasteswar
2016-11-01
Algal biofuels are becoming more economically competitive due to technological advances and government subsidies offering tax benefits and lower cost financing. These factors are linked, however, as the value of technical advances is affected by modeling assumptions regarding the growth conditions, process design, and financing of the production facility into which novel techniques are incorporated. Two such techniques, related to algal growth and dewatering, are evaluated in representative operating and financing scenarios using an integrated techno-economic model. Results suggest that these techniques can be valuable under specified conditions, but also that investment subsidies influence cost competitive facility design by incentivizing development of more capital intensive facilities (e.g., favoring hydrothermal liquefaction over transesterification-based facilities). Evaluating novel techniques under a variety of operational and financial scenarios highlights the set of site-specific conditions in which technical advances are most valuable, while also demonstrating the influence of subsidies linked to capital intensity. Copyright © 2016 Elsevier Ltd. All rights reserved.
40 CFR 35.917-5 - Public participation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... identification and evaluation of locations for waste water treatment facilities and of alternative treatment... treatment, reduce waste water volume, and encourage multiple use of facilities; (3) The evaluation of social... planning issues and decisions. (b) Basic Public Participation Program. Since waste water treatment...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Usui, Hideo; Izumo, Sari; Tachibana, Mitsuo
Some of nuclear facilities that would no longer be required have been decommissioned in JAEA (Japan Atomic Energy Agency). A lot of nuclear facilities have to be decommissioned in JAEA in near future. To implement decommissioning of nuclear facilities, it was important to make a rational decommissioning plan. Therefore, project management data evaluation system for dismantling activities (PRODIA code) has been developed, and will be useful for making a detailed decommissioning plan for an object facility. Dismantling of dry conversion facility in the uranium refining and conversion plant (URCP) at Ningyo-toge began in 2008. During dismantling activities, project management datamore » such as manpower and amount of waste generation have been collected. Such collected project management data has been evaluated and used to establish a calculation formula to calculate manpower for dismantling equipment of chemical process and calculate manpower for using a green house (GH) which was a temporary structure for preventing the spread of contaminants during dismantling. In the calculation formula to calculate project management data related to dismantling of equipment, the relation of dismantling manpower to each piece of equipment was evaluated. Furthermore, the relation of dismantling manpower to each chemical process was evaluated. The results showed promise for evaluating dismantling manpower with respect to each chemical process. In the calculation formula to calculate project management data related to use of the GH, relations of GH installation manpower and removal manpower to GH footprint were evaluated. Furthermore, the calculation formula for secondary waste generation was established. In this study, project management data related to dismantling of equipment and use of the GH were evaluated and analyzed. The project management data, manpower for dismantling of equipment, manpower for installation and removal of GH, and secondary waste generation from GH were considered. Establishment of the calculation formula for dismantling of each kind of equipment makes it possible to evaluate manpower for dismantling the whole facility. However, it is not easy to prepare calculation formula for all kinds of equipment that exist in the facility. Therefore, a simpler evaluation method was considered to calculate manpower based on facility characteristics. The results showed promise for evaluating dismantling manpower with respect to each chemical process. For dismantling of contaminated equipment, a GH has been used for protection of the spread of contamination. The use of a GH increases manpower for installation and removal of GH etc. Moreover, structural materials of the GH such as plastic sheets, adhesive tape become a burnable secondary waste. To create an effective dismantling plan, it is necessary to carefully consider use of a GH preliminarily. Thus, an evaluation method of project management data such as manpower and secondary waste generation was considered. The results showed promise for evaluating project management data of GH by using established calculation formula. (authors)« less
Naval Research Laboratory Major Facilities 2008
2008-10-01
Development Laboratory • Secure Supercomputing Facility • CBD/Tilghman Island IR Field Evaluation Facility • Ultra-Short-Pulse Laser Effects Research...EMI Test Facility • Proximity Operations Testbed GENERAL INFORMATION • Maps EX EC U TI V E D IR EC TO RA TE Code 1100 – Institute for Nanoscience...facility: atomic force microscope (AFM); benchtop transmission electron microscope (TEM); cascade probe station; critical point dryer ; dual beam focused
Auditing radiation sterilization facilities
NASA Astrophysics Data System (ADS)
Beck, Jeffrey A.
The diversity of radiation sterilization systems available today places renewed emphasis on the need for thorough Quality Assurance audits of these facilities. Evaluating compliance with Good Manufacturing Practices is an obvious requirement, but an effective audit must also evaluate installation and performance qualification programs (validation_, and process control and monitoring procedures in detail. The present paper describes general standards that radiation sterilization operations should meet in each of these key areas, and provides basic guidance for conducting QA audits of these facilities.
RETROFITTING CONTROL FACILITIES FOR WET-WEATHER FLOW CONTROL
Available technologies were evaluated to demonstrate the feasibility and cost effectiveness of retrofitting existing facilities to handle wet-weather flow (WWF). Cost/benefit relationships were compared to construction of new conventional control and treatment facilities. Desktop...
RETROFITTING CONTROL FACILITIES FOR WET-WEATHER FLOW TREATMENT
Available technologies were evaluated to demonstrate the technical feasibility and cost effectiveness of retrofitting existing facilities to handle wet-weather flow. Cost/benefit relationships were also compared to construction of new conventional control and treatment facilities...
The present situation of the irradiation application industry and irradiation facilities in Japan
NASA Astrophysics Data System (ADS)
Mizusawa, K.; Baba, T.
2003-08-01
The irradiation application industry and irradiation facilities in Japan have been making slow but steady progress for the past 2-3 years. Beside conventional applications, new ones such as carbon fibers and membrane filters have come into the market. There are a lot of new applications about to emerge. PE tubing, already is in the European market, is being evaluated by end users in Japan. Cleaning of dioxin in exhaust gas was successfully tested at a pilot plant. Cross-linked PTFE and polyamide are waiting customers' evaluations as an engineering plastic. Surface cross-linking of artificial polycarbonate teeth has yielded remarkable experimental results. Cross-linking of polycaprolactone will be useful for biodegradable products. Being aware of the future growth of irradiation industry, contract service providers opened new facilities or increased their capability. Beside in-house facilities, there are now three Co-60 facilities and nine EB facilities available for contract irradiation in Japan.
Environmental review of the Panda-Brandywine cogeneration project. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walters, G.; Keating, R.; Huggins, A.
1997-02-01
The Maryland Public Service Commission (PSC) granted a Certificate of Public Convenience and Necessity (CPCN) to Panda-Brandywine, L.P., to construct and operate a 248-megawatt (electric) generating station near Brandywine, Prince George`s County, Maryland. This report describes PPRP`s evaluation of the environmental and socioeconomic impacts of the Panda-Brandywine facility, summarizes the results of that evaluation, and presents recommendations for license conditions which have been incorporated into Panda`s CPCN. The document includes description of the proposed facility, host facility, and associated linear facilities (transmission line, pipelines); discussion of existing environmental and socioeconomic conditions at the site and in the vicinity; analysis ofmore » the potential air quality, surface water, biological, ground water, socioeconomic, cultural, and noise impacts from the proposed facility; and discussion of critical engineering issues associated with operation of the facility, including water supply, water discharge, and fuel handling.« less
Network Performance Evaluation Model for assessing the impacts of high-occupancy vehicle facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Janson, B.N.; Zozaya-Gorostiza, C.; Southworth, F.
1986-09-01
A model to assess the impacts of major high-occupancy vehicle (HOV) facilities on regional levels of energy consumption and vehicle air pollution emissions in urban aeas is developed and applied. This model can be used to forecast and compare the impacts of alternative HOV facility design and operation plans on traffic patterns, travel costs, model choice, travel demand, energy consumption and vehicle emissions. The model is designed to show differences in the overall impacts of alternative HOV facility types, locations and operation plans rather than to serve as a tool for detailed engineering design and traffic planning studies. The Networkmore » Performance Evaluation Model (NETPEM) combines several urban transportation planning models within a multi-modal network equilibrium framework including modules with which to define the type, location and use policy of the HOV facility to be tested, and to assess the impacts of this facility.« less
The Effectiveness and Need for Facility Based Nurse Aide Training Competency Evaluation Programs.
Mileski, Michael; McIlwain, Amber S; Kruse, Clemens Scott; Lieneck, Cristian; Sokan, Amanda
2016-01-01
It has become crucial for nursing facilities to rapidly train future nurse aides and remove any barriers to their matriculation into the field of care. Facilities feel the organizational burden of insufficient staffing and need to lever all effective programs to train future employees. The facility-based, Nurse Aide Training Competency Evaluation Programs (NATCEP) serve as a viable option to help fill shortages in the professional medical workforce. Data were analyzed from the National Nursing Assistant Survey to provide an overview of the benefits of using facility-trained nurse aides, versus those trained elsewhere, including their own perceptions of training and abilities. These findings also show the importance of facility based training programs for nurse aides on a global level. Providing training on site increases the efficiency and proficiency of nurse aides, making the transition to caregivers an easier for students, employers and residents.
NASA Technical Reports Server (NTRS)
Wong, Douglas T.
2010-01-01
Topics in this student project report include: biography, NASA history and structure, overview of Johnson Space Center facilities and major projects, and an overview of the Usability Testing and Analysis Facility (UTAF). The UTAF section slides include space habitat evaluations with mockups, crew space vehicle evaluations, and human factors research.
Evaluation of radiological dispersion/consequence codes supporting DOE nuclear facility SARs
DOE Office of Scientific and Technical Information (OSTI.GOV)
O`Kula, K.R.; Paik, I.K.; Chung, D.Y.
1996-12-31
Since the early 1990s, the authorization basis documentation of many U.S. Department of Energy (DOE) nuclear facilities has been upgraded to comply with DOE orders and standards. In this process, many safety analyses have been revised. Unfortunately, there has been nonuniform application of software, and the most appropriate computer and engineering methodologies often are not applied. A DOE Accident Phenomenology and Consequence (APAC) Methodology Evaluation Program was originated at the request of DOE Defense Programs to evaluate the safety analysis methodologies used in nuclear facility authorization basis documentation and to define future cost-effective support and development initiatives. Six areas, includingmore » source term development (fire, spills, and explosion analysis), in-facility transport, and dispersion/ consequence analysis (chemical and radiological) are contained in the APAC program. The evaluation process, codes considered, key results, and recommendations for future model and software development of the Radiological Dispersion/Consequence Working Group are summarized in this paper.« less
Antimicrobial stewardship in long term care facilities: what is effective?
Nicolle, Lindsay E
2014-02-12
Intense antimicrobial use in long term care facilities promotes the emergence and persistence of antimicrobial resistant organisms and leads to adverse effects such as C. difficile colitis. Guidelines recommend development of antimicrobial stewardship programs for these facilities to promote optimal antimicrobial use. However, the effectiveness of these programs or the contribution of any specific program component is not known. For this review, publications describing evaluation of antimicrobial stewardship programs for long term care facilities were identified through a systematic literature search. Interventions included education, guidelines development, feedback to practitioners, and infectious disease consultation. The studies reviewed varied in types of facilities, interventions used, implementation, and evaluation. Comprehensive programs addressing all infections were reported to have improved antimicrobial use for at least some outcomes. Targeted programs for treatment of pneumonia were minimally effective, and only for indicators of uncertain relevance for stewardship. Programs focusing on specific aspects of treatment of urinary infection - limiting treatment of asymptomatic bacteriuria or prophylaxis of urinary infection - were reported to be effective. There were no reports of cost-effectiveness, and the sustainability of most of the programs is unclear. There is a need for further evaluation to characterize effective antimicrobial stewardship for long term care facilities.
Yoon, Jeong-Ae; Park, Se-Gwan; Roh, Hyo-Lyun
2015-10-01
[Purpose] This study was conducted to compare the correlation between social interaction and activities of daily living (ADL) between community-dwelling and long-term care facility stroke patients. [Subjects and Methods] The Subjects were 65 chronic stroke patients (32 facility-residing, 33 community-dwelling). The Evaluation Social Interaction (ESI) tool was used to evaluate social interaction and the Assessment of Motor and Process Skills (AMPS) measure was used to evaluate ADL. [Results] Both social interaction and ADL were higher in community-dwelling than facility-residing stroke patients. There was a correlation between ESI and ADL for both motor and process skills among facility-residing patients, while only ADL process skills and ESI correlated among community-dwelling patients. In a partial correlation analysis using ADL motor and process skills as control variables, only process skills correlated with ESI. [Conclusion] For rehabilitation of stroke patients, an extended treatment process that combines ADL and social activities is likely to be required. Furthermore, treatment programs and institutional systems that can improve social interaction and promote health maintenance for community-dwelling and facility-residing chronic stroke patients are needed throughout the rehabilitation process.
Evaluation of the antipsychotic medication review process at four long-term facilities in Alberta.
Birney, Arden; Charland, Paola; Cole, Mollie; Aslam Arain, Mubashir
2016-01-01
The goal of this evaluation was to understand how four long-term care (LTC) facilities in Alberta have implemented medication reviews for the Appropriate Use of Antipsychotics (AUA) initiative. We aimed to determine how interprofessional (IP) collaboration was incorporated in the antipsychotic medication reviews and how the reviews had been sustained. Four LTC facilities in Alberta participated in this evaluation. We conducted semistructured interviews with 18 facility staff and observed one antipsychotic medication review at each facility. We analyzed data according to the following key components that we identified as relevant to the antipsychotic medication reviews: the structure of the reviews, IP interactions between the staff members, and strategies for sustaining the reviews. The duration of antipsychotic medication reviews ranged from 1 to 1.5 hours. The number of professions in attendance ranged from 3 to 9; a pharmacist led the review at two sites, while a registered nurse led the review at one site and a nurse practitioner at the remaining site. The number of residents discussed during the review ranged from 6 to 20. The process at some facilities was highly IP, demonstrating each of the six IP competencies. Other facilities conducted the review in a less IP manner due to challenges of physician involvement and staff workload, particularly of health care aides. Facilities that had an nurse practitioner on site were more efficient with the process of implementing recommendations resulting from the medication reviews. The LTC facilities were successful in implementing the medication review process and the process seemed to be sustainable. A few challenges were observed in the implementation process at two facilities. IP practice moved forward the goals of the AUA initiative to reduce the inappropriate use of antipsychotics.
Technology evaluation, assessment, modeling, and simulation: the TEAMS capability
NASA Astrophysics Data System (ADS)
Holland, Orgal T.; Stiegler, Robert L.
1998-08-01
The United States Marine Corps' Technology Evaluation, Assessment, Modeling and Simulation (TEAMS) capability, located at the Naval Surface Warfare Center in Dahlgren Virginia, provides an environment for detailed test, evaluation, and assessment of live and simulated sensor and sensor-to-shooter systems for the joint warfare community. Frequent use of modeling and simulation allows for cost effective testing, bench-marking, and evaluation of various levels of sensors and sensor-to-shooter engagements. Interconnectivity to live, instrumented equipment operating in real battle space environments and to remote modeling and simulation facilities participating in advanced distributed simulations (ADS) exercises is available to support a wide- range of situational assessment requirements. TEAMS provides a valuable resource for a variety of users. Engineers, analysts, and other technology developers can use TEAMS to evaluate, assess and analyze tactical relevant phenomenological data on tactical situations. Expeditionary warfare and USMC concept developers can use the facility to support and execute advanced warfighting experiments (AWE) to better assess operational maneuver from the sea (OMFTS) concepts, doctrines, and technology developments. Developers can use the facility to support sensor system hardware, software and algorithm development as well as combat development, acquisition, and engineering processes. Test and evaluation specialists can use the facility to plan, assess, and augment their processes. This paper presents an overview of the TEAMS capability and focuses specifically on the technical challenges associated with the integration of live sensor hardware into a synthetic environment and how those challenges are being met. Existing sensors, recent experiments and facility specifications are featured.
NASA Technical Reports Server (NTRS)
George, William K.; Rae, William J.; Woodward, Scott H.
1991-01-01
The importance of frequency response considerations in the use of thin-film gages for unsteady heat transfer measurements in transient facilities is considered, and methods for evaluating it are proposed. A departure frequency response function is introduced and illustrated by an existing analog circuit. A Fresnel integral temperature which possesses the essential features of the film temperature in transient facilities is introduced and is used to evaluate two numerical algorithms. Finally, criteria are proposed for the use of finite-difference algorithms for the calculation of the unsteady heat flux from a sampled temperature signal.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steinke, R.G.; Mueller, C.; Knight, T.D.
1998-03-01
The computational fluid dynamics code CFX4.2 was used to evaluate steady-state thermal-hydraulic conditions in the Fluor Daniel, Inc., Nuclear Material Storage Facility renovation design (initial 30% of Title 1). Thirteen facility cases were evaluated with varying temperature dependence, drywell-array heat-source magnitude and distribution, location of the inlet tower, and no-flow curtains in the drywell-array vault. Four cases of a detailed model of the inlet-tower top fixture were evaluated to show the effect of the canopy-cruciform fixture design on the air pressure and flow distributions.
Pavement testing facility : effects of tire pressure on flexible pavement response performance
DOT National Transportation Integrated Search
1989-08-01
The effects of tire pressure on flexible pavement response and performance were evaluated using data from the first phase of research at the Federal Highway Administration's Pavement Testing Facility. The Accelerated Loading Facility testing machine ...
Evaluation of renewable energy alternatives for highway maintenance facilities.
DOT National Transportation Integrated Search
2013-12-01
A considerable annual energy budget is used for heating, lighting, cooling and operating ODOT : maintenance facilities. Such facilities contain vehicle repair and garage bays, which are large open : spaces with high heating demand in winter. The main...
Building Condition and Suitability Evaluation Manual.
ERIC Educational Resources Information Center
MGT of America, Inc., Tallahassee, FL.
This educational facility evaluation manual contains the overall building condition rating form and the supporting check sheets which have been field tested in several states and, where appropriate, modified for use in the Idaho School Facilities Needs Assessment. The exterior building condition form examines the foundation, structure, walls,…
An Evaluation of Facility Maintenance and Repair Strategies of Select Companies
2002-09-01
challenge for facility maintenance professionals is balancing the cost of facility Maintenance and Repair (M&R) with the benefits derived from those...maintenance professionals is balancing the cost of facility Maintenance and Repair (M&R) with the benefits derived from those facilities. This thesis...private organizations may also benefit from an analysis of the practices in use by successful corporations. The second group to benefit from this
Evaluating Past and Future USCG Use of Ohmsett Test Facility
2016-10-01
and Renewable Energy Test Facility, that was previously known as a fully capitalized acronym, Ohmsett. This facility is located on the U.S. Naval...Oil Spill Response Research and Renewable Energy Test Facility, that was previously known as a fully capitalized acronym, Ohmsett. This facility is...Incident Management Systems NSF National Strike Force NWS Naval Weapons Station Ohmsett National Oil Spill Response Research and Renewable Energy
Weightless Environment Training Facility (WETF) materials coating evaluation, volume 2
NASA Technical Reports Server (NTRS)
1995-01-01
This volume consists of Appendices A and B to the report on the Weightless Environment Training Facility Materials Coating Evaluation project. The project selected 10 coating systems to be evaluated in six separate exposure environments, and subject to three tests for physical properties. Appendix A holds the coating system, surface preparation, and application data. Appendix B holds the coating material infrared spectra.
ERIC Educational Resources Information Center
Harmon, Marcel; Larroque, Andre; Maniktala, Nate
2012-01-01
The New Mexico Public School Facilities Authority (NMPSFA) is the agency responsible for administering state-funded capital projects for schools statewide. Post occupancy evaluation (POE) is the tool selected by NMPSFA for measuring project outcomes. The basic POE process for V. Sue Cleveland High School (VSCHS) consisted of a series of field…
Facilities Audit Workbook: A Self-Evaluation for Higher Education.
ERIC Educational Resources Information Center
Kaiser, Harvey H.
The purpose and scope of a facilities audit and steps in conducting an audit are outlined, and facility ratings forms that can be used in the process are included. The audit is presented as a part of the comprehensive facilities management approach, and the users and different audit uses are also addressed. The audit design phase includes deciding…
PROTOTYPE EICHER FISH SCREEN AND EVALUATION FACILITY, INSTALLED IN 1990 ...
PROTOTYPE EICHER FISH SCREEN AND EVALUATION FACILITY, INSTALLED IN 1990 ON #1 PENSTOCK. PROJECT SPONSORED BY THE ELECTRICAL POWER RESEARCH INSTITUTE TO TRANSFER FISH DOWNSTREAM PAST THE TURBINES. PHOTO BY JET LOWE, HAER, 1995. - Elwha River Hydroelectric System, Elwha Hydroelectric Dam & Plant, Port Angeles, Clallam County, WA
75 FR 51500 - Advisory Committee on Reactor Safeguards
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-20
..., October 14, 2009 (74 FR 52829-52830). Thursday, September 9, 2010, Conference Room T2-B1, Two White Flint... Fabrication Facility and the Associated Safety Evaluation Report (Open/ Closed)--The Committee will hold... the MOX Fuel Fabrication Facility and the associated Safety Evaluation Report. [Note: A portion of...
USDA-ARS?s Scientific Manuscript database
A field research facility with two pairs of replicated agricultural test plots (four total) was established at a location in northwest Ohio during 2005 for the purpose of studying water table management strategies. Initial efforts at this field research facility were devoted to evaluating difference...
Evaluating Quality in Educational Facilities
ERIC Educational Resources Information Center
Abend, Allen; Ornstein, Sheila Walbe; Baltas, Emmanuel; de la Garza, Jaime; Watson, Chris; Lange, Kurt; von Ahlefeld, Hannah
2006-01-01
In 2005, the OECD Programme on Educational Building (PEB) organised two international experts' group meetings to discuss how countries define and evaluate quality in educational facilities. The research and experiences of six experts are presented in this article, in addition to the lessons learned from the experts' group meetings. The director of…
Custodians/Security Program Evaluation.
ERIC Educational Resources Information Center
Ennis, Bob
The Custodians/Security Department is a support service of the Des Moines (Iowa) Independent Community School District. Responsibilities of the department do not stop with the care of the facility, but extend to providing a clean, safe environment for all who use school facilities. Program evaluation in the 1993-94 school year reveals a total…
The purpose of the activities described in this document is to provide a demonstration of the procedures and methodologies described within the "Guidance for Evaluating Landfill Gas Emissions from Closed or Abandoned Facilities" (Guidance). This demonstration provides an example ...
Special Education Evaluation Project for University Affiliated Facilities. Final Report.
ERIC Educational Resources Information Center
Burrello, Leonard C.; And Others
The final report of the Special Education Evaluation Project for 16 University Affiliated Facilities (UAF) centers provides a chronological review of the project which focused on the training of persons to work with mentally retarded or other handicapped individuals. Outlined are project objectives including the development of descriptors useful…
USDA-ARS?s Scientific Manuscript database
A lab-scaled simulated bedded pack model was developed to study air quality and nutrient composition of deep-bedded packs found in cattle monoslope facilities. This protocol has been used to effectively evaluate many different bedding materials, environmental variables (temperature, humidity), and ...
Evaluation of multiple emission point facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miltenberger, R.P.; Hull, A.P.; Strachan, S.
In 1970, the New York State Department of Environmental Conservation (NYSDEC) assumed responsibility for the environmental aspect of the state's regulatory program for by-product, source, and special nuclear material. The major objective of this study was to provide consultation to NYSDEC and the US NRC to assist NYSDEC in determining if broad-based licensed facilities with multiple emission points were in compliance with NYCRR Part 380. Under this contract, BNL would evaluate a multiple emission point facility, identified by NYSDEC, as a case study. The review would be a nonbinding evaluation of the facility to determine likely dispersion characteristics, compliance withmore » specified release limits, and implementation of the ALARA philosophy regarding effluent release practices. From the data collected, guidance as to areas of future investigation and the impact of new federal regulations were to be developed. Reported here is the case study for the University of Rochester, Strong Memorial Medical Center and Riverside Campus.« less
Variation in fistula use across dialysis facilities: is it explained by case-mix?
Tangri, Navdeep; Moorthi, Ranjani; Tighiouhart, Hocine; Meyer, Klemens B; Miskulin, Dana C
2010-02-01
Arteriovenous fistulas (AVFs) remain the preferred vascular access for hemodialysis patients. Dialysis facilities that fail to meet Centers for Medicare & Medicaid Services goals cite patient case-mix as a reason for low AVF prevalence. This study aimed to determine the magnitude of the variability in AVF usage across dialysis facilities and the extent to which patient case-mix explains it. The vascular access used in 10,112 patients dialyzed at 173 Dialysis Clinic Inc. facilities from October 1 to December 31, 2004, was evaluated. The access in use was considered to be an AVF if it was used for >70% of hemodialysis treatments. Mixed-effects models with a random intercept for dialysis facilities evaluated the effect of facilities on AVF usage. Sequentially adjusted multivariate models measured the extent to which patient factors (case-mix) explain variation across facilities in AVF rates. 3787 patients (38%) were dialyzed using AVFs. There was a significant facility effect: 7.6% of variation in AVF use was attributable to facility. This was reduced to 7.1% after case-mix adjustment. There were no identified specific facility-level factors that explained the interfacility variation. AVF usage varies across dialysis facilities, and patient case-mix did not reduce this variation. In this study, 92% of the total variation in AVF usage was due to patient factors, but most were not measurable. A combination of patient factors and process indicators should be considered in adjudicating facility performance for this quality indicator.
Waweru, Evelyn; Goodman, Catherine; Kedenge, Sarah; Tsofa, Benjamin; Molyneux, Sassy
2016-03-01
In many African countries, user fees have failed to achieve intended access and quality of care improvements. Subsequent user fee reduction or elimination policies have often been poorly planned, without alternative sources of income for facilities. We describe early implementation of an innovative national health financing intervention in Kenya; the health sector services fund (HSSF). In HSSF, central funds are credited directly into a facility's bank account quarterly, and facility funds are managed by health facility management committees (HFMCs) including community representatives. HSSF is therefore a finance mechanism with potential to increase access to funds for peripheral facilities, support user fee reduction and improve equity in access. We conducted a process evaluation of HSSF implementation based on a theory of change underpinning the intervention. Methods included interviews at national, district and facility levels, facility record reviews, a structured exit survey and a document review. We found impressive achievements: HSSF funds were reaching facilities; funds were being overseen and used in a way that strengthened transparency and community involvement; and health workers' motivation and patient satisfaction improved. Challenges or unintended outcomes included: complex and centralized accounting requirements undermining efficiency; interactions between HSSF and user fees leading to difficulties in accessing crucial user fee funds; and some relationship problems between key players. Although user fees charged had not increased, national reduction policies were still not being adhered to. Finance mechanisms can have a strong positive impact on peripheral facilities, and HFMCs can play a valuable role in managing facilities. Although fiduciary oversight is essential, mechanisms should allow for local decision-making and ensure that unmanageable paperwork is avoided. There are also limits to what can be achieved with relatively small funds in contexts of enormous need. Process evaluations tracking (un)intended consequences of interventions can contribute to regional financing and decentralization debates. © The Author 2015. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine.
DOT National Transportation Integrated Search
2005-07-05
The Oregon Department of Transportation (ODOT) has installed several stormwater : treatment facilities throughout the State to improve the quality of runoff discharged from : highways. These facilities include a variety of both above ground and below...
Board evaluation and effectiveness: models, components and perspectives.
Scharf, M; Marty, D; Barnsley, J
1994-01-01
Health facility boards are being challenged to increase their effectiveness in the face of the changing health care environment. To this end, accreditation standards require boards to develop methods of evaluating their governing function and performance. During a survey of governance issues, the authors interviewed a group of health service executives with respect to board evaluation at their facilities. The responses yielded insights relating to models and components of evaluation, board missions and policies, mentoring programs and trustee education and orientation.
Ade-Oshifogun, Jochebed Bosede; Dufelmeier, Thaddeus
2012-01-01
This article describes a quality improvement process for "do not return" (DNR) notices for healthcare supplemental staffing agencies and healthcare facilities that use them. It is imperative that supplemental staffing agencies partner with healthcare facilities in assuring the quality of supplemental staff. Although supplemental staffing agencies attempt to ensure quality staffing, supplemental staff are sometimes subjectively evaluated by healthcare facilities as "DNR." The objective of this article is to describe a quality improvement process to prevent and manage "DNR" within healthcare organizations. We developed a curriculum and accompanying evaluation tool by adapting Rampersad's problem-solving discipline approach: (a) definition of area(s) for improvement; (b) identification of all possible causes; (c) development of an action plan; (d) implementation of the action plan; (e) evaluation for program improvement; and (f) standardization of the process. Face and content validity of the evaluation tool was ascertained by input from a panel of experienced supplemental staff and nursing faculty. This curriculum and its evaluation tool will have practical implications for supplemental staffing agencies and healthcare facilities in reducing "DNR" rates and in meeting certification/accreditation requirements. Further work is needed to translate this process into future research. © 2012 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chapman, T.E.
1993-10-01
The Federal Facilities Compliance Act (the Act) of 1992 waives sovereign immunity for federal facilities for fines and penalties under the provisions of the Resource Recovery and Conservation Act, state, interstate, and local hazardous and solid waste management requirements. However, for three years the Act delays the waiver for violations involving US Department of Energy (DOE) facilities. The Act, however, requires that the DOE prepare a Conceptual Site Treatment Plan (CSTP) for each of its sites that generate or store mixed wastes (MWs). The purpose of the CSTP is to present DOE`s preliminary evaluations of the development of treatment capacitiesmore » and technologies for treating a site`s MW. This CSTP presents the preliminary capacity and technology evaluation for the Laboratory for Energy-Related Health Research (LEHR). The five identified MW streams at LEHR are evaluated to the extent possible given available information. Only one MW stream is sufficiently well defined to permit a technology evaluation to be performed. Two other MW streams are in the process of being characterized so that an evaluation can be performed. The other two MW streams will be generated by the decommissioning of inactive facilities onsite within the next five years.« less
300 Area Building Retention Evaluation Mitigation Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. J. McBride
2007-07-03
Evaluate the long-term retention of several facilities associated with the PNNL Capability Replacement Laboratory and other Hanfor mission needs. WCH prepared a mitigation plan for three scenarios with different release dates for specific buildings. The evaluations present a proposed plan for providing utility services to retained facilities in support of a long-term (+20 year) lifespan in addition to temporary services to buildings with specified delayed release dates.
Villasís-Keever, Miguel Ángel; Rizzoli-Córdoba, Antonio; Delgado-Ginebra, Ismael; Mares-Serratos, Blanca Berenice; Martell-Valdez, Liliana; Sánchez-Velázquez, Olivia; Reyes-Morales, Hortensia; O'Shea-Cuevas, Gabriel; Aceves-Villagrán, Daniel; Carrasco-Mendoza, Joaquín; Antillón-Ocampo, Fátima Adriana; Villagrán-Muñoz, Víctor Manuel; Halley-Castillo, Elizabeth; Baqueiro-Hernández, César Iván; Pizarro-Castellanos, Mariel; Martain-Pérez, Itzamara Jacqueline; Palma-Tavera, Josuha Alexander; Vargas-López, Guillermo; Muñoz-Hernández, Onofre
The Child Development Evaluation (CDE) test designed and validated in Mexico has been used as a screening tool for developmental problems in primary care facilities across Mexico. Heterogeneous results were found among those states where these were applied, despite using the same standardized training model for application. The objective was to evaluate a supervision model for quality of application of the CDE test at primary care facilities. A study was carried out in primary care facilities from three Mexican states to evaluate concordance of the results between supervisor and primary care personnel who administered the test using two different methods: direct observation (shadow study) or reapplication of the CDE test (consistency study). There were 380 shadow studies applied to 51 psychologists. General concordance of the shadow study was 86.1% according to the supervisor: green 94.5%, yellow 73.2% and red 80.0%. There were 302 re-test evaluations with a concordance of 88.1% (n=266): green 96.8%, yellow 71.7% and red 81.8%. There were no differences between CDE test subgroups by age. Both shadow and re-test study were adequate for the evaluation of the quality of the administration of the CDE Test and may be useful as a model of supervision in primary care facilities. The decision of which test to use relies on the availability of supervisors. Copyright © 2015 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.
Control of Listeria species food safety at a poultry food production facility.
Fox, Edward M; Wall, Patrick G; Fanning, Séamus
2015-10-01
Surveillance and control of food-borne human pathogens, such as Listeria monocytogenes, is a critical aspect of modern food safety programs at food production facilities. This study evaluated contamination patterns of Listeria species at a poultry food production facility, and evaluated the efficacy of procedures to control the contamination and transfer of the bacteria throughout the plant. The presence of Listeria species was studied along the production chain, including raw ingredients, food-contact, non-food-contact surfaces, and finished product. All isolates were sub-typed by pulsed-field gel electrophoresis (PFGE) to identify possible entry points for Listeria species into the production chain, as well as identifying possible transfer routes through the facility. The efficacy of selected in-house sanitizers against a sub-set of the isolates was evaluated. Of the 77 different PFGE-types identified, 10 were found among two or more of the five categories/areas (ingredients, food preparation, cooking and packing, bulk packing, and product), indicating potential transfer routes at the facility. One of the six sanitizers used was identified as unsuitable for control of Listeria species. Combining PFGE data, together with information on isolate location and timeframe, facilitated identification of a persistent Listeria species contamination that had colonized the facility, along with others that were transient. Copyright © 2015 Elsevier Ltd. All rights reserved.
The Nature of Scatter at the DARHT Facility and Suggestions for Improved Modeling of DARHT Facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morneau, Rachel Anne
This report describes the US Stockpile Stewardship Program which is meant to sustain and evaluate nuclear weapon stockpile with no underground nuclear tests. This research will focus on DARHT, the Dual Axis Radiographic Hydrodynamic Test facility.
Robinson, Claire H; Annis, Ann M; Forman, Jane; Krein, Sarah L; Yankey, Nicholas; Duffy, Sonia A; Taylor, Beth; Sales, Anne E
2016-08-01
To assess implementation of the Veterans Health Administration staffing methodology directive. In 2010 the Veterans Health Administration promulgated a staffing methodology directive for inpatient nursing units to address staffing and budget forecasting. A qualitative multi-case evaluation approach assessed staffing methodology implementation. Semi-structured telephone interviews were conducted from March - June 2014 with Nurse Executives and their teams at 21 facilities. Interviews focused on the budgeting process, implementation experiences, use of data, leadership support, and training. An implementation score was created for each facility using a 4-point rating scale. The scores were used to select three facilities (low, medium and high implementation) for more detailed case studies. After analysing interview summaries, the evaluation team developed a four domain scoring structure: (1) integration of staffing methodology into budget development; (2) implementation of the Directive elements; (3) engagement of leadership and staff; and (4) use of data to support the staffing methodology process. The high implementation facility had leadership understanding and endorsement of staffing methodology, confidence in and ability to work with data, and integration of staffing methodology results into the budgeting process. The low implementation facility reported poor leadership engagement and little understanding of data sources and interpretation. Implementation varies widely across facilities. Implementing staffing methodology in facilities with complex and changing staffing needs requires substantial commitment at all organizational levels especially for facilities that have traditionally relied on historical levels to budget for staffing. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.
Facilitymetrics for Big Ocean Science: Towards Improved Measurement of Scientific Impact
NASA Astrophysics Data System (ADS)
Juniper, K.; Owens, D.; Moran, K.; Pirenne, B.; Hallonsten, O.; Matthews, K.
2016-12-01
Cabled ocean observatories are examples of "Big Science" facilities requiring significant public investments for installation and ongoing maintenance. Large observatory networks in Canada and the United States, for example, have been established after extensive up-front planning and hundreds of millions of dollars in start-up costs. As such, they are analogous to particle accelerators and astronomical observatories, which may often be required to compete for public funding in an environment of ever-tightening national science budget allocations. Additionally, the globalization of Big Science compels these facilities to respond to increasing demands for demonstrable productivity, excellence and competitiveness. How should public expenditures on "Big Science" facilities be evaluated and justified in terms of benefits to the countries that invest in them? Published literature counts are one quantitative measure often highlighted in the annual reports of large science facilities. But, as recent research has demonstrated, publication counts can lead to distorted characterizations of scientific impact, inviting evaluators to calculate scientific outputs in terms of costs per publication—a ratio that can be simplistically misconstrued to conclude Big Science is wildly expensive. Other commonly promoted measurements of Big Science facilities include technical reliability (a.k.a. uptime), provision of training opportunities for Highly Qualified Personnel, generation of commercialization opportunities, and so forth. "Facilitymetrics" is a new empirical focus for scientometrical studies, which has been applied to the evaluation and comparison of synchrotron facilities. This paper extends that quantitative and qualitative examination to a broader inter-disciplinary comparison of Big Science facilities in the ocean science realm to established facilities in the fields of astronomy and particle physics.
Facilitymetrics for Big Ocean Science: Towards Improved Measurement of Scientific Impact
NASA Astrophysics Data System (ADS)
Juniper, K.; Owens, D.; Moran, K.; Pirenne, B.; Hallonsten, O.; Matthews, K.
2016-02-01
Cabled ocean observatories are examples of "Big Science" facilities requiring significant public investments for installation and ongoing maintenance. Large observatory networks in Canada and the United States, for example, have been established after extensive up-front planning and hundreds of millions of dollars in start-up costs. As such, they are analogous to particle accelerators and astronomical observatories, which may often be required to compete for public funding in an environment of ever-tightening national science budget allocations. Additionally, the globalization of Big Science compels these facilities to respond to increasing demands for demonstrable productivity, excellence and competitiveness. How should public expenditures on "Big Science" facilities be evaluated and justified in terms of benefits to the countries that invest in them? Published literature counts are one quantitative measure often highlighted in the annual reports of large science facilities. But, as recent research has demonstrated, publication counts can lead to distorted characterizations of scientific impact, inviting evaluators to calculate scientific outputs in terms of costs per publication—a ratio that can be simplistically misconstrued to conclude Big Science is wildly expensive. Other commonly promoted measurements of Big Science facilities include technical reliability (a.k.a. uptime), provision of training opportunities for Highly Qualified Personnel, generation of commercialization opportunities, and so forth. "Facilitymetrics" is a new empirical focus for scientometrical studies, which has been applied to the evaluation and comparison of synchrotron facilities. This paper extends that quantitative and qualitative examination to a broader inter-disciplinary comparison of Big Science facilities in the ocean science realm to established facilities in the fields of astronomy and particle physics.
NASA Astrophysics Data System (ADS)
Guiquan, Xi; Lin, Cong; Xuehui, Jin
2018-05-01
As an important platform for scientific and technological development, large -scale scientific facilities are the cornerstone of technological innovation and a guarantee for economic and social development. Researching management of large-scale scientific facilities can play a key role in scientific research, sociology and key national strategy. This paper reviews the characteristics of large-scale scientific facilities, and summarizes development status of China's large-scale scientific facilities. At last, the construction, management, operation and evaluation of large-scale scientific facilities is analyzed from the perspective of sustainable development.
USDA-ARS?s Scientific Manuscript database
A field research facility with two pairs of replicated agricultural test plots (four total) was established at a location in northwest Ohio during 2005 for the purpose of studying water table management strategies. Initial efforts at this field research facility were devoted to evaluating difference...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-08
... evaluation, is as follows: Facility: Battelle Laboratories King Avenue Location: Columbus, Ohio. Job Titles and/or Job Duties: All Atomic Weapons Employees who worked at the King Avenue facility in Columbus...: Stuart L. Hinnefeld, Director, Division of Compensation Analysis and Support, National Institute for...
Title I Institutionalized Facilities Program. O.E.E. Evaluation Report, 1981-82.
ERIC Educational Resources Information Center
New York City Board of Education, Brooklyn, NY. Office of Educational Evaluation.
This report documents the 1981-82 evaluation of the Elementary and Secondary Education Act, Title I, Part B, Institutional Facilities Program carried out through the Division of Special Education of the New York City public schools. Using a diagnostic-prescriptive methodology, the program provided after-school and pull-out individualized remedial…
Power source evaluation capabilities at Sandia National Laboratories
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doughty, D.H.; Butler, P.C.
1996-04-01
Sandia National Laboratories maintains one of the most comprehensive power source characterization facilities in the U.S. National Laboratory system. This paper describes the capabilities for evaluation of fuel cell technologies. The facility has a rechargeable battery test laboratory and a test area for performing nondestructive and functional computer-controlled testing of cells and batteries.
ERIC Educational Resources Information Center
Texas State Technical Coll., Waco.
A project was conducted to determine if interactive video programs could produce positive results in literacy programs. During the project, staff from a technical college developed a task analysis, curriculum, and evaluation measures for the training of facilities maintenance workers in mathematical concepts. From this activity, an instructional…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-04
..., simulation labs, and a fitness center; and support facilities such as administrative offices, dormitories, a dining hall, and emergency response facilities. During the initial planning process, GSA conducted a comprehensive site evaluation process that identified and evaluated 41 candidate sites in the vicinity of the...
The purpose of the activities described in this document is to provide a demonstration of the procedures and methodologies described within the "Guidance for Evaluating Landfill Gas Emissions from Closed or Abandoned Facilities" (Guidance). This demonstration provides an example ...
49 CFR Appendix A to Part 611 - Description of Measures Used for Project Evaluation
Code of Federal Regulations, 2014 CFR
2014-10-01
... weighted average of current year and horizon year. (d) Congestion Relief. [Reserved] (e) Cost-effectiveness... benefit and cost evaluation methods. In addition, FTA may establish warrants for one or more of these... cost of the facilities (when such facilities are designed to achieve a third-party certification or to...
49 CFR Appendix A to Part 611 - Description of Measures Used for Project Evaluation
Code of Federal Regulations, 2013 CFR
2013-10-01
... weighted average of current year and horizon year. (d) Congestion Relief. [Reserved] (e) Cost-effectiveness... benefit and cost evaluation methods. In addition, FTA may establish warrants for one or more of these... cost of the facilities (when such facilities are designed to achieve a third-party certification or to...
Rundek, Tatjana; Brown, Scott C; Wang, Kefeng; Dong, Chuanhui; Farrell, Mary Beth; Heller, Gary V; Gornik, Heather L; Hutchisson, Marge; Needleman, Laurence; Benenati, James F; Jaff, Michael R; Meier, George H; Perese, Susana; Bendick, Phillip; Hamburg, Naomi M; Lohr, Joann M; LaPerna, Lucy; Leers, Steven A; Lilly, Michael P; Tegeler, Charles; Alexandrov, Andrei V; Katanick, Sandra L
2014-10-01
There is limited information on the accreditation status and geographic distribution of vascular testing facilities in the US. The Centers for Medicare & Medicaid Services (CMS) provide reimbursement to facilities regardless of accreditation status. The aims were to: (1) identify the proportion of Intersocietal Accreditation Commission (IAC) accredited vascular testing facilities in a 5% random national sample of Medicare beneficiaries receiving outpatient vascular testing services; (2) describe the geographic distribution of these facilities. The VALUE (Vascular Accreditation, Location & Utilization Evaluation) Study examines the proportion of IAC accredited facilities providing vascular testing procedures nationally, and the geographic distribution and utilization of these facilities. The data set containing all facilities that billed Medicare for outpatient vascular testing services in 2011 (5% CMS Outpatient Limited Data Set (LDS) file) was examined, and locations of outpatient vascular testing facilities were obtained from the 2011 CMS/Medicare Provider of Services (POS) file. Of 13,462 total vascular testing facilities billing Medicare for vascular testing procedures in a 5% random Outpatient LDS for the US in 2011, 13% (n=1730) of facilities were IAC accredited. The percentage of IAC accredited vascular testing facilities in the LDS file varied significantly by US region, p<0.0001: 26%, 12%, 11%, and 7% for the Northeast, South, Midwest, and Western regions, respectively. Findings suggest that the proportion of outpatient vascular testing facilities that are IAC accredited is low and varies by region. Increasing the number of accredited vascular testing facilities to improve test quality is a hypothesis that should be tested in future research. © The Author(s) 2014.
Evaluating Efficiencies in Preventive Medicine: Comparing Approaches Between the Services
2016-02-29
Prank] + Σn [(Td * L) + (Td * Pdiem)] C: Cost in dollars T: Time allocated for training in days Prank: Pay for the expected rank in dollars per...of food service facilities and storage areas, berthing spaces, childcare facilities, recreational facilities, potable water and wastewater disposal
1982-01-01
A-81-154. A-81-155. Adopt procedures and directives to use the student evaluations prepared by academic personnel at the FAA controller training...density ATC facilities. This determination, which is based on academic evaluations and the performance of the trainee in the radar training facility...81-154) Adopt procedures and directives to use the student evaluations prepared by academic personnel at the FAA controller training center as a
2009-09-01
elevated background pressure, compared nude Faraday probe designs, and evaluated design modifications to minimize uncertainty due to charge exchange...evaluated Faraday probe design and facility background pressure on collected ion current. A comparison of two nude Faraday probe designs concluded...140.5 Plasma potential in the region surrounding a nude Faraday probe has been measured to study the possibility of probe bias voltage acting as a
Strategic facility planning improves capital decision making.
Reeve, J R
2001-03-01
A large, Midwestern IDS undertook a strategic facility-planning process to evaluate its facility portfolio and determine how best to allocate future investments in facility development. The IDS assembled a facility-planning team, which initiated the planning process with a market analysis to determine future market demands and identify service areas that warranted facility expansion. The team then analyzed each of the IDS's facilities from the perspective of uniform capacity measurements, highest and best use compared with needs, building condition and investment-worthiness, and facility growth and site development opportunities. Based on results of the analysis, the strategy adopted entailed, in part, shifting some space from inpatient care to ambulatory care services and demolishing and replacing the 11 percent of facilities deemed to be in the worst condition.
Clean room survey and assessment, volume 5, appendix H
NASA Technical Reports Server (NTRS)
1991-01-01
The scope of this task is to perform a comparative analysis of the various Environmental Control Life Support System (ECLSS) options for different growth scenarios. The Space Station Freedom ECLSS design and existing ground-based clean room facilities are used as a baseline for comparison. Specifically addressed here are the ground based clean room facilities at the Marshall Space Flight Center (MSFC). Given here is an evaluation of the facilities, equipment, technologies, and procedures used to maintain specified environments in typical aerospace industrial areas. Twenty-five specific clean rooms are evaluated. The objectives were to collect, compare, and catalog data for each specified facility in the areas of engineering and design, construction materials, work stations, contamination control, particulate elimination, entry systems, and instrumentation, and to make recommendations concerning enhancements required to assure an efficient and orderly evolution of MSFC clean room environmental control facilities.
Waweru, Evelyn; Goodman, Catherine; Kedenge, Sarah; Tsofa, Benjamin; Molyneux, Sassy
2016-01-01
In many African countries, user fees have failed to achieve intended access and quality of care improvements. Subsequent user fee reduction or elimination policies have often been poorly planned, without alternative sources of income for facilities. We describe early implementation of an innovative national health financing intervention in Kenya; the health sector services fund (HSSF). In HSSF, central funds are credited directly into a facility’s bank account quarterly, and facility funds are managed by health facility management committees (HFMCs) including community representatives. HSSF is therefore a finance mechanism with potential to increase access to funds for peripheral facilities, support user fee reduction and improve equity in access. We conducted a process evaluation of HSSF implementation based on a theory of change underpinning the intervention. Methods included interviews at national, district and facility levels, facility record reviews, a structured exit survey and a document review. We found impressive achievements: HSSF funds were reaching facilities; funds were being overseen and used in a way that strengthened transparency and community involvement; and health workers’ motivation and patient satisfaction improved. Challenges or unintended outcomes included: complex and centralized accounting requirements undermining efficiency; interactions between HSSF and user fees leading to difficulties in accessing crucial user fee funds; and some relationship problems between key players. Although user fees charged had not increased, national reduction policies were still not being adhered to. Finance mechanisms can have a strong positive impact on peripheral facilities, and HFMCs can play a valuable role in managing facilities. Although fiduciary oversight is essential, mechanisms should allow for local decision-making and ensure that unmanageable paperwork is avoided. There are also limits to what can be achieved with relatively small funds in contexts of enormous need. Process evaluations tracking (un)intended consequences of interventions can contribute to regional financing and decentralization debates. PMID:25920355
The infrared spectrograph during the SIRTF pre-definition phase
NASA Technical Reports Server (NTRS)
Houck, James R.
1988-01-01
A test facility was set up to evaluate back-illuminated impurity band detectors constructed for an infrared spectrograph to be used on the Space Infrared Telescope Facility (SIRTF). Equipment built to perform the tests on these arrays is described. Initial tests have been geared toward determining dark current and read noise for the array. Four prior progress reports are incorporated into this report. They describe the first efforts in the detector development and testing effort; testing details and a new spectrograph concept; a discussion of resolution issues raised by the new design; management activities; a review of computer software and testing facility hardware; and a review of the preamplifier constructed as well as a revised schematic of the detector evaluation facility.
NASA Technical Reports Server (NTRS)
Torr, Douglas G.
1991-01-01
A summary of the status of the Cross-section Facility at MSFC is presented. A facility was designed, fabricated, assembled, tested, and operated for measurement of differential scattering cross sections important to understand the induced environment for a vehicle (e.g., Space Station) in low earth orbit. A user's manual for the facility is also presented. The performance of the facility was evaluated and found to be satisfactory in all the essential areas. Differential scattering cross sections were measured and results for the scattering measurements are included. Input to the development of the Ultraviolet Imager Optical System is also discussed. Design, fabrication, and evaluation of UV filters using a four-layer aluminum base are reported.
Decentralized School vs. Centralized School. Investigation No. 3.
ERIC Educational Resources Information Center
Paseur, C. Herbert
A report is presented of a comparative investigation of a decentralized and a centralized school facility. Comparative data are provided regarding costs of the facilities, amount of educational area provided by the facilities, and types of educational areas provided. Evaluative comments are included regarding cost savings versus educational…
Title I, Part B, Institutionalized Facilities Program, Summer 1982. Annual Evaluation Report.
ERIC Educational Resources Information Center
New York City Board of Education, Brooklyn, NY. Office of Educational Evaluation.
This 1982 summer Title I, Part B, Institutionalized Facilities Program provided supplementary career instruction to 188 students residing in facilities for neglected and delinquent children and youth. This report briefly describes the program, providing information on methodology, physical setting, equipment, and supplies; population and class…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-25
... Nearby Facilities and on Transportation Routes Near Nuclear Power Plants AGENCY: Nuclear Regulatory... Nearby Facilities and on Transportation Routes Near Nuclear Power Plants.'' This regulatory guide describes for applicants seeking nuclear power reactor licenses and licensees of nuclear power reactors...
Planning the Library Media Center Facility for the 1990s and Beyond.
ERIC Educational Resources Information Center
Texas Education Agency, Austin.
This manual presents recommendations for incorporating present and future technological changes into workable, efficient, pleasant school library media facilities in two major sections: Planning the Facility and Activity Areas. The first section addresses the planning process (appointing the building committee, evaluating the library media…
76 FR 19523 - Finding of No Significant Impact (FONSI) for the Beaumont Layberth Facility
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-07
... the EA is to evaluate the potential environmental impacts from the construction of a Layberth facility... Significant Impact (FONSI) for the Beaumont Layberth Facility AGENCY: U.S. Department of Transportation, Maritime Administration. ACTION: Notice of Availability of Finding of No Significant Impact. SUMMARY...
Planning the School Food Service Facilities. Revised 1967.
ERIC Educational Resources Information Center
Utah State Board of Education, Salt Lake City.
Evaluations of food service equipment, kitchen design and food service facilities are comprehensively reviewed for those concerned with the planning and equipping of new school lunchrooms or the remodeling of existing facilities. Information is presented in the form of general guides adaptable to specific local situations and needs, and is…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-14
... warranted by the evaluation, is as follows: Facility: Wah Chang. Location: Albany, Oregon. Job Titles and/or Job Duties: All employees who worked in any buildings. Period of Employment: Operational period from... of Compensation Analysis and Support, National Institute for Occupational Safety and Health (NIOSH...
ERIC Educational Resources Information Center
Jacobs, C. O.
A study evaluated the feasibility of introducing unheated outside air into the airstream of a cross-flow welding exhaust system to reduce heating energy costs of a school welding laboratory. The physical facility used was the agricultural mechanics laboratory at the University of Arizona, which is similar to facilities in which instruction in…
ERIC Educational Resources Information Center
Wilson, Leslie; And Others
This evaluation project was designed to assess 37 persons (ages 21-72) who had moved from intermediate care facilities or skilled nursing facilities into innovative one-person or two-person community integrated living arrangements as a result of the Supported Placements in Integrated Community Environments project. The 37 persons had severe or…
ERIC Educational Resources Information Center
Miklas, Michael P., Jr.
Section 109(b) of the 1972 Federal Water Pollution Control Act Amendments authorized funding for the construction of statewide water treatment training facilities. Described in this report is work conducted by Southwest Research Institute (SwRI) to: (1) aid in developing updated 109(b) Guidance Documents; (2) characterize and evaluate existing…
Measurement and evaluation of percolation drainage systems capacity in real conditions
NASA Astrophysics Data System (ADS)
Markovic, G.; Zelenakova, M.
2017-10-01
The drainage system must ensure a safe disposal of the surface water without endangering the buildings and safety of people. Despite the common use of rainwater infiltration facilities, there is still only limited data available evaluating the long-term capacity of such systems especially for underground infiltration facilities. This study presents experimental measurements and evaluation of long-term infiltration efficiency in real conditions and emphasizes the importance of hydrogeological survey. The measurements of infiltration efficiency were applied to an existing percolation drainage system - infiltration shafts. Infiltration shafts were made in year 2007 so that its drainage operation takes more than 8 years. This study was started in 2011 and still continues and presents 5 years measurements of infiltration efficiency for this infiltration facility.
NASA Technical Reports Server (NTRS)
Marks, D. A.; Gendiellee, R. E.; Kelly, T. M.; Giovannello, M. A.
1974-01-01
Ground processing and operation activities for selected automated and sortie payloads are evaluated. Functional flow activities are expanded to identify payload launch site facility and support requirements. Payload definitions are analyzed from the launch site ground processing viewpoint and then processed through the expanded functional flow activities. The requirements generated from the evaluation are compared with those contained in the data sheets. The following payloads were included in the evaluation: Long Duration Exposure Facility; Life Sciences Shuttle Laboratory; Biomedical Experiments Scientific Satellite; Dedicated Solar Sortie Mission; Magnetic Spectrometer; and Mariner Jupiter Orbiter. The expanded functional flow activities and descriptions for the automated and sortie payloads at the launch site are presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piette, Mary Ann; Sezgen, Osman; Watson, David S.
This report describes the results of a research project to develop and evaluate the performance of new Automated Demand Response (Auto-DR) hardware and software technology in large facilities. Demand Response (DR) is a set of activities to reduce or shift electricity use to improve electric grid reliability, manage electricity costs, and ensure that customers receive signals that encourage load reduction during times when the electric grid is near its capacity. The two main drivers for widespread demand responsiveness are the prevention of future electricity crises and the reduction of electricity prices. Additional goals for price responsiveness include equity through costmore » of service pricing, and customer control of electricity usage and bills. The technology developed and evaluated in this report could be used to support numerous forms of DR programs and tariffs. For the purpose of this report, we have defined three levels of Demand Response automation. Manual Demand Response involves manually turning off lights or equipment; this can be a labor-intensive approach. Semi-Automated Response involves the use of building energy management control systems for load shedding, where a preprogrammed load shedding strategy is initiated by facilities staff. Fully-Automated Demand Response is initiated at a building or facility through receipt of an external communications signal--facility staff set up a pre-programmed load shedding strategy which is automatically initiated by the system without the need for human intervention. We have defined this approach to be Auto-DR. An important concept in Auto-DR is that a facility manager is able to ''opt out'' or ''override'' an individual DR event if it occurs at a time when the reduction in end-use services is not desirable. This project sought to improve the feasibility and nature of Auto-DR strategies in large facilities. The research focused on technology development, testing, characterization, and evaluation relating to Auto-DR. This evaluation also included the related decisionmaking perspectives of the facility owners and managers. Another goal of this project was to develop and test a real-time signal for automated demand response that provided a common communication infrastructure for diverse facilities. The six facilities recruited for this project were selected from the facilities that received CEC funds for new DR technology during California's 2000-2001 electricity crises (AB970 and SB-5X).« less
Reproductive health services in Malawi: an evaluation of a quality improvement intervention.
Rawlins, Barbara J; Kim, Young-Mi; Rozario, Aleisha M; Bazant, Eva; Rashidi, Tambudzai; Bandazi, Sheila N; Kachale, Fannie; Sanghvi, Harshad; Noh, Jin Won
2013-01-01
this study was to evaluate the impact of a quality improvement initiative in Malawi on reproductive health service quality and related outcomes. (1) post-only quasi-experimental design comparing observed service quality at intervention and comparison health facilities, and (2) a time-series analysis of service statistics. sixteen of Malawi's 23 district hospitals, half of which had implemented the Performance and Quality Improvement (PQI) intervention for reproductive health at the time of the study. a total of 98 reproductive health-care providers (mostly nurse-midwives) and 139 patients seeking family planning (FP), antenatal care (ANC), labour and delivery (L&D), or postnatal care (PNC) services. health facility teams implemented a performance and quality improvement (PQI) intervention over a 3-year period. Following an external observational assessment of service quality at baseline, facility teams analysed performance gaps, designed and implemented interventions to address weaknesses, and conducted quarterly internal assessments to assess progress. Facilities qualified for national recognition by complying with at least 80% of reproductive health clinical standards during an external verification assessment. key measures include facility readiness to provide quality care, observed health-care provider adherence to clinical performance standards during service delivery, and trends in service utilisation. intervention facilities were more likely than comparison facilities to have the needed infrastructure, equipment, supplies, and systems in place to offer reproductive health services. Observed quality of care was significantly higher at intervention than comparison facilities for PNC and FP. Compared with other providers, those at intervention facilities scored significantly higher on client assessment and diagnosis in three service areas, on clinical management and procedures in two service areas, and on counselling in one service area. Service statistics suggest that the PQI intervention increased the number of Caesarean sections, but showed no impact on other indicators of service utilisation and skilled care. the PQI intervention showed a positive impact on the quality of reproductive health services. The effects of the intervention on service utilisation had likely not yet been fully realized, since none of the facilities had achieved national recognition before the evaluation. Staff turnover needs to be reduced to maximise the effectiveness of the intervention. the PQI intervention evaluated here offers an effective way to improve the quality of health services in low-resource settings and should continue to be scaled up in Malawi. Copyright © 2011 Elsevier Ltd. All rights reserved.
State Compliance Monitoring Expectations | ECHO | US EPA
EPA sets national goals for how frequently facilities should be evaluated by the authorized enforcement agency for three programs included in ECHO (Clean Air Act, Clean Water Act, and Resource Conservation and Recovery Act). EPA develops Compliance Monitoring Strategies (CMSs) to ensure that the regulated facilities across the country are evaluated for compliance on a regular basis. Information on CMSs, evaluations (such as on-site inspections), and inspection frequency goals that are defined by each program is included.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meyer, A.F. Jr.
1980-07-02
A site visit was made in company with the DOE-OPTA-EA Safety and Health Official for the purpose of providing that official with technical assistance in evaluating the validity of an earlier DOE-OPTA recommendation exempting this facility from the Safety and Analysis and Review backfit requirements of DOE Order 5481.1. A further purpose of the visit was to assess and evaluate the occupational safety and health program at this facility, as compared with the criteria and guidelines contained in ASFE Order 5481.1. Adequate documentation regarding compliance with codes, standards, and regulations were observed at this facility. There is in existence anmore » ongoing continuous safety analysis effort for both modifications or additions to this facility. Adequate environmental safeguards and plans and procedures were observed. The SARS backfit exemption is appropriate. The occupational safety and health program is in many ways a model for the scope of work and nature of hazards involved, and is consistent with ASFE guidelines and statutory requirements.« less
Spruit, Anouk; Wissink, Inge B; Stams, Geert Jan J M
2016-01-01
According to the risk-need-responsivity model of offender, assessment and rehabilitation treatment should target specific factors that are related to re-offending. This study evaluates the residential care of Filipino juvenile offenders using the risk-need-responsivity model. Risk analyses and criminogenic needs assessments (parenting style, aggression, relationships with peers, empathy, and moral reasoning) have been conducted using data of 55 juvenile offenders in four residential facilities. The psychological care has been assessed using a checklist. Statistical analyses showed that juvenile offenders had a high risk of re-offending, high aggression, difficulties in making pro-social friends, and a delayed socio-moral development. The psychological programs in the residential facilities were evaluated to be poor. The availability of the psychological care in the facilities fitted poorly with the characteristics of the juvenile offenders and did not comply with the risk-need-responsivity model. Implications for research and practice are discussed. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Stradling, J.; Pippen, D. L.
1985-01-01
The NASA Johnson Space Center White Sands Test Facility (WSTF) performs aerospace materials testing and evaluation. Established in 1963, the facility grew from a NASA site dedicated to the development of space engines for the Apollo project to a major test facility. In addition to propulsion tests, it tests materials and components, aerospace fluids, and metals and alloys in simulated space environments.
Implementation research to improve quality of maternal and newborn health care, Malawi.
Brenner, Stephan; Wilhelm, Danielle; Lohmann, Julia; Kambala, Christabel; Chinkhumba, Jobiba; Muula, Adamson S; De Allegri, Manuela
2017-07-01
To evaluate the impact of a performance-based financing scheme on maternal and neonatal health service quality in Malawi. We conducted a non-randomized controlled before and after study to evaluate the effects of district- and facility-level performance incentives for health workers and management teams. We assessed changes in the facilities' essential drug stocks, equipment maintenance and clinical obstetric care processes. Difference-in-difference regression models were used to analyse effects of the scheme on adherence to obstetric care treatment protocols and provision of essential drugs, supplies and equipment. We observed 33 health facilities, 23 intervention facilities and 10 control facilities and 401 pregnant women across four districts. The scheme improved the availability of both functional equipment and essential drug stocks in the intervention facilities. We observed positive effects in respect to drug procurement and clinical care activities at non-intervention facilities, likely in response to improved district management performance. Birth assistants' adherence to clinical protocols improved across all studied facilities as district health managers supervised and coached clinical staff more actively. Despite nation-wide stock-outs and extreme health worker shortages, facilities in the study districts managed to improve maternal and neonatal health service quality by overcoming bottlenecks related to supply procurement, equipment maintenance and clinical performance. To strengthen and reform health management structures, performance-based financing may be a promising approach to sustainable improvements in quality of health care.
Gallè, Francesca; Di Onofrio, Valeria; Arpesella, Marisa; Bacci, Silvia; Bianco, Antonino; Brandi, Giorgio; Bruno, Stefania; Anastasi, Daniela; Carraro, Elisabetta; Flacco, Maria Elena; Giampaoli, Saverio; Izzotti, Alberto; Leoni, Erica; Bertoncello, Chiara; Minelli, Liliana; Napoli, Christian; Nobile, Carmelo; Pasquarella, Cesira; Liguori, Giorgio; Romano Spica, Vincenzo
2015-01-01
In Italy, students from Movement Science (MS) Degree Courses often work in sport and recreational facilities before graduation. The employment conditions of Movement Science students working in sport/recreational facilities were investigated, and the management and structural features of the facilities were evaluated, including safety policies. Regional differences were also considered. Questionnaires were administered to undergraduate and graduate students (N = 4,217) in 17 Universities. Students' perceptions of the quality of the facilities where they had been employed was evaluated using multivariate analysis. A latent class model with covariates was used to evaluate how variables relating to participants, employment facilities or regions influence their opinions. A high proportion of MS students were employed in sporting facilities (undergraduate level: 33% ; graduate level: 55%), in most cases without any formal employment contracts. Both the structural and hygienic features, as well as the professional knowledge of the staff, were considered good to excellent by the majority of participants (about 70%). Communication of the basic behavioral rules was considered adequate by 61-63% of undergraduate students and 71-75% of graduate students, while nearly half of the participants were dissatisfied with the staff safety training. Correlations between the perceived good structural/hygienic conditions, the presence of regulations and training programs for the staff were investigated. Differences regarding occupational level and safety training among different regions of Italy were also observed. Italian students in Movement Science were easily employed in sport/recreational facilities, but frequently without a formal contract. This is a consequence of the lack of specific regulations in the field of recreational/leisure employment and could have negative implications, especially in terms of safety.
Kirby, Alanna T; Traub-Dargatz, Josie L; Hill, Ashley E; Kogan, Lori R; Morley, Paul S; Heird, James C
2010-11-15
To develop a questionnaire for self-assessment of biosecurity practices at equine boarding facilities and to evaluate infectious disease control practices in these facilities in Colorado. Cross-sectional study. 64 equine boarding facilities in Colorado. Survey questions were rated according to importance for prevention and containment of equine infectious diseases. Point values (range, 0 to 20) were assigned for possible responses, with greater values given for optimal infection control methods. Questionnaires were mailed to equine boarding facilities in Colorado advertised on the World Wide Web. Survey responses were compared with assessments made by a member of the research team during visits to 30 randomly selected facilities. Agreement among results was analyzed via a kappa test and rated as poor, fair, moderate, substantial, or nearly perfect. Survey responses were received for 64 of 163 (39%) equine boarding facilities. Scores ranged from 106 to 402 points (maximum possible score, 418). Most facilities received better scores for movement and housing of equids than for other sections of the survey. Respondents at 24 of 48 (50%) facilities that routinely received new equids reported isolation of new arrivals. Agreement between self-assessment by survey respondents and evaluation by a member of the research team was determined to be fair to substantial. Most equine boarding facilities have opportunities to improve measures for prevention or containment of contagious diseases (eg, isolation of newly arrived equids and use of written health management protocols). Most self-assessments of infection control practices were accurate.
Preliminary design for a maglev development facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coffey, H.T.; He, J.L.; Chang, S.L.
1992-04-01
A preliminary design was made of a national user facility for evaluating magnetic-levitation (maglev) technologies in sizes intermediate between laboratory experiments and full-scale systems. A technical advisory committee was established and a conference was held to obtain advice on the potential requirements of operational systems and how the facility might best be configured to test these requirements. The effort included studies of multiple concepts for levitating, guiding, and propelling maglev vehicles, as well as the controls, communications, and data-acquisition and -reduction equipment that would be required in operating the facility. Preliminary designs for versatile, dual 2-MVA power supplies capable ofmore » powering attractive or repulsive systems were developed. Facility site requirements were identified. Test vehicles would be about 7.4 m (25 ft) long, would weigh form 3 to 7 metric tons, and would operate at speeds up to 67 m/s (150 mph) on a 3.3-km (2.05-mi) elevated guideway. The facility would utilize modular vehicles and guideways, permitting the substitution of levitation, propulsion, and guideway components of different designs and materials for evaluation. The vehicle would provide a test cell in which individual suspension or propulsion components or subsystems could be tested under realistic conditions. The system would allow economical evaluation of integrated systems under varying weather conditions and in realistic geometries.« less
NASA Astrophysics Data System (ADS)
Huang, Tielan; Wang, Yunpeng; Zhang, Jinlan
2017-07-01
In this study, simulation and evaluation of low impact development in resident district was carried out based on Storm Water Management Model (SWMM) and GIS method. In the evaluation model, we added 3 kinds of low impact development facilities, namely permeable pavement, rainwater garden, and green roof. These facilities are used alone or in combination. The model was run under five different rainfall reappearing periods. The simulation results using low impact development facilities were compared with simulation results under the current situation and undeveloped state. The results show that the total amount of runoff was greatly reduced by using various types of low impact development facilities in the urban residential district. The maximum reduction rate was using permeable pavement, reached 29.9%, followed was using rainwater garden, and the worst was using green roof. The lowest cost of reduction of the total amount of runoff was using permeable pavement, the followed was using rainwater garden, and the highest was using green roof. The combination scheme of various low impact development facilities has the highest efficiency of reducing total amount of runoff, and the lowest cost, which considering of the actual situation of the study area. The study indicated that application of low impact development facilities can reduce surface runoff effectively, which should be a useful way for prevention of urban waterlogging.
Hamoda, Reem E; Gander, Jennifer C; McPherson, Laura J; Arriola, Kimberly J; Cobb, Loren; Pastan, Stephen O; Plantinga, Laura; Browne, Teri; Hartmann, Erica; Mulloy, Laura; Zayas, Carlos; Krisher, Jenna; Patzer, Rachel E
2018-01-15
The Reducing Disparities in Access to kidNey Transplantation Community Study (RaDIANT) was an End-Stage Renal Disease (ESRD) Network 6-developed, dialysis facility-level randomized trial testing the effectiveness of a 1-year multicomponent education and quality improvement intervention in increasing referral for kidney transplant evaluation among selected Georgia dialysis facilities. To assess implementation of the RaDIANT intervention, we conducted a process evaluation at the conclusion of the intervention period (January-December 2014). We administered a 20-item survey to the staff involved with transplant education in 67 dialysis facilities randomized to participate in intervention activities. Survey items assessed facility participation in the intervention (fidelity and reach), helpfulness and willingness to continue intervention activities (sustainability), suggestions for improving intervention components (sustainability), and factors that may have influenced participation and study outcomes (context). We defined high fidelity to the intervention as completing 11 or more activities, and high participation in an activity as having at least 75% participation across intervention facilities. Staff from 65 of the 67 dialysis facilities completed the questionnaire, and more than half (50.8%) reported high adherence (fidelity) to RaDIANT intervention requirements. Nearly two-thirds (63.1%) of facilities reported that RaDIANT intervention activities were helpful or very helpful, with 90.8% of facilities willing to continue at least one intervention component beyond the study period. Intervention components with high participation emphasized staff and patient-level education, including in-service staff orientations, patient and family education programs, and patient educational materials. Suggested improvements for intervention activities emphasized addressing financial barriers to transplantation, with financial education materials perceived as most helpful among RaDIANT educational materials. Variation in facility-level fidelity of the RADIANT intervention did not significantly influence the mean difference in proportion of patients referred pre- (2013) and post-intervention (2014). We found high fidelity to the RaDIANT multicomponent intervention at the majority of intervention facilities, with sustainability of select intervention components at intervention facilities and feasibility for dissemination across ESRD Networks. Future modification of the intervention should emphasize financial education regarding kidney transplantation and amend intervention components that facilities perceive as time-intensive or non-sustainable. Clinicaltrials.gov number NCT02092727 . Registered 13 Mar 2014 (retrospectively registered).
Damschroder, Laura J; Reardon, Caitlin M; Sperber, Nina; Robinson, Claire H; Fickel, Jacqueline J; Oddone, Eugene Z
2017-06-01
The Telephone Lifestyle Coaching (TLC) program provided telephone-based coaching for six lifestyle behaviors to 5321 Veterans at 24 Veterans Health Administration (VHA) medical facilities. The purpose of the study was to conduct an evaluation of the TLC program to identify factors associated with successful implementation. A mixed-methods study design was used. Quantitative measures of organizational readiness for implementation and facility complexity were used to purposively select a subset of facilities for in-depth evaluation. Context assessments were conducted using interview transcripts. The Consolidated Framework for Implementation Research (CFIR) was used to guide qualitative data collection and analysis. Factors most strongly correlated with referral rates included having a skilled implementation leader who used effective multi-component strategies to engage primary care clinicians as well as general clinic structures that supported implementation. Evaluation findings pointed to recommendations for local and national leaders to help anticipate and mitigate potential barriers to successful implementation.
Common ground, not a battle ground. Violence prevention at a detoxification facility.
Adamson, Mary A; Vincent, Audrey A; Cundiff, Jeff
2009-08-01
This article evaluates the results of a workplace violence prevention program implemented in a Colorado detoxification facility. The program interventions are modeled after federal Occupational Safety and Health Administration guidelines and use theories from both nursing and criminology for philosophy and direction. Serving as its own control, the detoxification facility shares data measured over a 4-year period, demonstrating a sharp decline in assault rates after program implementation. The importance of administrative controls, environmental adjustments, recordkeeping and evaluation, and education and training are emphasized as key components of success. Copyright (c) 2009, SLACK Incorporated.
CONCEPTUAL DESIGN ASSESSMENT FOR THE CO-FIRING OF BIO-REFINERY SUPPLIED LIGNIN PROJECT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ted Berglund; Jeffrey T. Ranney; Carol L. Babb
2001-04-01
The major aspects of this project are proceeding toward completion. Prior to this quarter, design criteria, tentative site selection, facility layout, and preliminary facility cost estimates have been completed and issued for review. Processing of bio-solids was completed, providing material for the pilot operations. Pilot facility design, equipment selection, and modification were completed during the fourth quarter of 2000. Initial pilot facility shakedown was completed during the fourth quarter. After some unavoidable delays, a suitable representative supply of municipal solid waste (MSW) feed material was procured. During this quarter (first quarter of 2001), shredding of the feed material was completedmore » and final feed conditioning was completed. Pilot facility hydrolysis production was completed to produce lignin for co-fire testing. Pilot facility modifications continued to improve facility operations and performance during the first quarter of 2001. Samples of the co-fire fuel material were sent to the co-fire facility for evaluation. The TVA-Colbert facility has neared completion of the task to evaluate the co-location of the Masada facility on the operation of the power generation facility. The TVA-Colbert fossil plant is fully capable of providing a reliable steam supply. The preferred steam supply connection points and steam pipeline routing have been identified. The environmental review of the pipeline routing has been completed and no major impacts have been identified. Detailed assessment of steam export impacts on the Colbert boiler system have been completed and a cost estimate for steam supply system is being developed.« less
Respirator use and its impact on particulate matter exposure in aluminum manufacturing facilities.
Liu, Sa; Noth, Elizabeth; Eisen, Ellen; Cullen, Mark R; Hammond, Katharine
2018-05-31
Objectives As part of a large epidemiologic study of particulate health effect, this study aimed to report respirator use among total particulate matter (TPM) samples collected in a major aluminum manufacturing company from 1966‒2013 and evaluate the impact of respirator-use adjustment on exposure estimation. Methods Descriptive analyses were performed to evaluate respirator use across facilities and by facility type and job. Protection factors were applied to TPM measurements for recorded respirator use. Estimated TPM exposure for each job ‒ before and after respirator-use adjustment ‒ were compared to assess the impact of adjustment on exposure estimation. Results Respirator use was noted for 37% of 12 402 full-shift personal TPM samples. Measured TPM concentration ranged from less than detectable to 8220 mg/m3, with arithmetic mean, median and standard deviation being 10.6, 0.87 and 130 mg/m 3 , respectively. Respirators were used more often in smelting facilities (52% of TPM measurements) than in fabricating (17%) or refinery facilities (28%) (P<0.01). Sixty-two percent of jobs in smelting facilities were subject to respirator-use adjustment, whereas it was 20% and 70% in fabricating and refinery facilities, respectively. Applying protection factors to TPM measurements significantly reduced estimated job mean TPM exposures and changed exposure categories in these facilities, with larger impact in smelting than fabricating facilities. Conclusions Respirator use varied by time, facility and job. Adjusting respirator use resulted in differential impact in smelting and fabricating facilities, which will need to be incorporated into ongoing epidemiologic studies accordingly.
PK-12 Public Educational Facilities Master Plan Evaluation Guide
ERIC Educational Resources Information Center
21st Century School Fund, 2011
2011-01-01
Proper planning of school facilities is critical for all school districts no matter how large or small, whether major construction is in the works or the district is managing enrollment declines. When school districts properly plan for their school facilities they have better schools, more public use and higher value for public spending. This…
77 FR 73060 - Standard Review Plan for Review of Fuel Cycle Facility License Applications
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-07
... NUCLEAR REGULATORY COMMISSION [NRC-2012-0220] Standard Review Plan for Review of Fuel Cycle... 1, ``Standard Review Plan (SRP) for the Review of a License Application for a Fuel Cycle Facility... for a fuel cycle facility (NUREG-1520) provides NRC staff guidance for reviewing and evaluating the...
Test facility for the evaluation of microwave transmission components
NASA Astrophysics Data System (ADS)
Fong, C. G.; Poole, B. R.
1985-10-01
A Low Power Test Facility (LPTF) was developed to evaluate the performance of Electron Cyclotron Resonance Heating (ECRH) microwave transmission components for the Mirror Fusion Test Facility (MFTF-B). The facility generates 26 to 60 GHz in modes of TE01, TE02, or TE03 launched at power levels of 1/2 milliwatt. The propagation of the RF as it radiates from either transmitting or secondary reflecting microwave transmission components is recorded by a discriminating crystal detector mechanically manipulated at constant radius in spherical coordinates. The facility is used to test, calibrate, and verify the design of overmoded, circular waveguide components, quasi-optical reflecting elements before high power use. The test facility consists of microwave sources and metering components, such as VSWR, power and frequency meters, a rectangular TE10 to circular TE01 mode transducer, mode filter, circular TE01 to 2.5 in. diameter overmoded waveguide with mode converters for combination of TE01 to TE03 modes. This assembly then connects to a circular waveguide launcher or the waveguide component under test.
Use of the Homeland-Defense Operational Planning System (HOPS) for Emergency Management
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durling, Jr., R L; Price, D E
2005-12-16
The Homeland-Defense Operational Planning System (HOPS), is a new operational planning tool leveraging Lawrence Livermore National Laboratory's expertise in weapons systems and in sparse information analysis to support the defense of the U.S. homeland. HOPS provides planners with a basis to make decisions to protect against acts of terrorism, focusing on the defense of facilities critical to U.S. infrastructure. Criticality of facilities, structures, and systems is evaluated on a composite matrix of specific projected casualty, economic, and sociopolitical impact bins. Based on these criteria, significant unidentified vulnerabilities are identified and secured. To provide insight into potential successes by malevolent actors,more » HOPS analysts strive to base their efforts mainly on unclassified open-source data. However, more cooperation is needed between HOPS analysts and facility representatives to provide an advantage to those whose task is to defend these facilities. Evaluated facilities include: refineries, major ports, nuclear power plants and other nuclear licensees, dams, government installations, convention centers, sports stadiums, tourist venues, and public and freight transportation systems. A generalized summary of analyses of U.S. infrastructure facilities will be presented.« less
Risk Assessment Using The Homeland-Defense Operational Planning System (HOPS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Price, D E; Durling, R L
2005-10-10
The Homeland-Defense Operational Planning System (HOPS), is a new operational planning tool leveraging Lawrence Livermore National Laboratory's expertise in weapons systems and in sparse information analysis to support the defense of the U.S. homeland. HOPS provides planners with a basis to make decisions to protect against acts of terrorism, focusing on the defense of facilities critical to U.S. infrastructure. Criticality of facilities, structures, and systems is evaluated on a composite matrix of specific projected casualty, economic, and sociopolitical impact bins. Based on these criteria, significant unidentified vulnerabilities are identified and secured. To provide insight into potential successes by malevolent actors,more » HOPS analysts strive to base their efforts mainly on unclassified open-source data. However, more cooperation is needed between HOPS analysts and facility representatives to provide an advantage to those whose task is to defend these facilities. Evaluated facilities include: refineries, major ports, nuclear power plants and other nuclear licensees, dams, government installations, convention centers, sports stadiums, tourist venues, and public and freight transportation systems. A generalized summary of analyses of U.S. infrastructure facilities will be presented.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baumann, B.L.; Miller, R.L.
1983-10-01
This document presents, in summary form, generic conceptual information relevant to the decommissioning of a reference research reactor (RRR). All of the data presented were extracted from NUREG/CR-1756 and arranged in a form that will provide a basis for future comparison studies for the Evaluation of Nuclear Facility Decommissioning Projects (ENFDP) program.
Structural Shielding Design and Evaluation for Megavoltage X- and Gamma-Ray Radiotherapy Facilities.
Glasgow, Glenn P
2006-09-01
Structural Shielding Design and Evaluation for Megavoltage X- and Gamma-Ray Radiotherapy Facilities NCRP Report No. 151, 2005, 246 pp. (Hardcover $100). National Council on Radiation Protection and Measurements, 7910 Woodmont Avenue, Suite 400, Bethesda, MD 20814-3095. ISBN-10 0-0929600-87-8; http://www.NCRPonline.org. © 2006 American Association of Physicists in Medicine.
J.W. Van Sambeek; Robert L. McGraw; John M. Kabrick; Mark V. Coggeshall; Irene M. Unger; Daniel C. Dey
2007-01-01
Information about the flood tolerance of most plants has been obtained from either observations following natural floods or pot studies with amended soils. To better evaluate and compare flood tolerance among hardwood seedlings and ground covers for use in riparian buffer and bottomland plantings, a large outdoor facility with natural floodplain soils is needed where...
NASA Technical Reports Server (NTRS)
Dever, Joyce A.; Degroh, Kim K.; Stidham, Curtis R.; Stueber, Thomas J.; Dever, Therese M.; Rodriguez, Elvin; Terlep, Judith A.
1992-01-01
In order to assess the low Earth orbit (LEO) durability of candidate space materials, it is necessary to use ground laboratory facilities which provide LEO environmental effects. A facility combining vacuum thermal cycling and vacuum ultraviolet (VUV) radiation has been designed and constructed at NASA Lewis Research Center for this purpose. This facility can also be operated without the VUV lamps. An additional facility can be used to provide VUV exposure only. By utilizing these facilities, followed by atomic oxygen exposure in an RF plasma asher, the effects of the individual vacuum thermal cycling and VUV environments can be compared to the effect of the combined vacuum thermal cycling/VUV environment on the atomic oxygen durability of materials. The synergistic effects of simulated LEO environmental conditions on materials were evaluated by first exposing materials to vacuum thermal cycling, VUV, and vacuum thermal cycling/VUV environments followed by exposure to atomic oxygen in an RP plasma asher. Candidate space power materials such as atomic oxygen protected polyimides and solar concentrator mirrors were evaluated using these facilities. Characteristics of the Vacuum Thermal Cycling/VUV Exposure Facility which simulates the temperature sequences and solar ultraviolet radiation exposure that would be experienced by a spacecraft surface in LEO are discussed. Results of durability evaluations of some candidate space power materials to the simulated LEO environmental conditions will also be discussed. Such results have indicated that for some materials, atomic oxygen durability is affected by previous exposure to thermal cycling and/or VUV exposure.
Evaluation and Selection of Renewable Energy Technologies for Highway Maintenance Facilities
NASA Astrophysics Data System (ADS)
Andrews, Taylor
The interest in renewable energy has been increasing in recent years as attempts to reduce energy costs as well the consumption of fossil fuels are becoming more common. Companies and organizations are recognizing the increasing reliance on limited fossil fuels' resources, and as competition and costs for these resources grow, alternative solutions are becoming more appealing. Many federally run buildings and associations also have the added pressure of meeting the mandates of federal energy policies that dictate specific savings or reductions. Federal highway maintenance facilities run by the Department of Transportation fall into this category. To help meet energy saving goals, an investigation into potential renewable energy technologies was completed for the Ohio Department of Transportation. This research examined several types of renewable energy technologies and the major factors that affect their performance and evaluated their potential for implementation at highway maintenance facilities. Facilities energy usage data were provided, and a facility survey and site visits were completed to enhance the evaluation of technologies and the suitability for specific projects. Findings and technology recommendations were presented in the form of selection matrices, which were designed to help make selections in future projects. The benefits of utilization of other tools such as analysis software and life cycle assessments were also highlighted. These selection tools were designed to be helpful guides when beginning the pursuit of a renewable energy technology for highway maintenance facilities, and can be applied to other similar building types and projects. This document further discusses the research strategies and findings as well as the recommendations that were made to the personnel overseeing Ohio's highway maintenance facilities.
Weightless Environment Training Facility (WETF) materials coating evaluation, volume 3
NASA Technical Reports Server (NTRS)
1995-01-01
This volume consists of Appendices C, D, E, and F to the report on the Weightless Environment Training Facility Materials Coating Evaluation project. The project selected 10 coating systems to be evaluated in six separate exposure environments, and subject to three tests for physical properties. Appendix C is the photographic appendix of the test panels. Appendix D details methods and procedures. Appendix E lists application equipment costs. Appendix F is a compilation of the solicitation of the candidate coating systems.
Dynamic Modeling and Evaluation of Recurring Infrastructure Maintenance Budget Determination Methods
2005-03-01
represent the annual M&R costs for the entire facility (Melvin, 1992). This method requires immense amounts of detailed data for each facility to be...and where facility and infrastructure maintenance must occur. Uzarski et al (1995) discuss that the data gathered produces a candidate list that can... facilities or an infrastructure plant. Government agencies like the DoD, major universities, and large corporations are the major players. Data
1987-08-01
take place in both contractor and government facilities. The on-orbit evaluation could utilize modified launch facilities depending on the launch...technological issues : o Telescope Optics: Verify that the distortions associated vith large optical elements satisfy detection and tracking requirements; verify...Validation program vould be car- ried out at contractor facilities that 1’ave not been identified and at six government facilities (Arnold Engineering
Iyer, Hari S; Kamanzi, Emmanuel; Mugunga, Jean Claude; Finnegan, Karen; Uwingabiye, Alice; Shyaka, Edward; Niyonzima, Saleh; Hirschhorn, Lisa R; Drobac, Peter C
2015-01-01
While health systems strengthening (HSS) interventions are recommended by global health policy experts to improve population health in resource-limited settings, few examples exist of evaluations of HSS interventions conducted at the district level. In 2009, a partnership between Partners In Health (PIH), a non-governmental organization, and the Rwandan Ministry of Health (RMOH) was provided funds to implement and evaluate a district-level HSS intervention in two rural districts of Rwanda. The partnership provided limited funds to 14 health centers for targeted systems support in 2010; six others received support prior to the intervention (reference). RMOH health systems norms were mapped across the WHO HSS framework, scored from 0 to 10 and incorporated into a rapid survey assessing 11 domains of facility readiness. Stakeholder meetings allowed partnership leaders to review results, set priorities, and allocate resources. Investments included salary support, infrastructure improvements, medical equipment, and social support for patients. We compared facility domain scores from the start of the intervention to 12 months and tested for correlation between change in score and change in funding allocation to assess equity in our approach. We found significant improvements among intervention facilities from baseline to 12 months across several domains [infrastructure (+4, p=0.0001), clinical services (+1.2, p=0.03), infection and sanitation control (+0.6, p=0.03), medical equipment (+1.0, p=0.02), information use (+2, p=0.002)]. Composite score across domains improved from 6.2 at baseline to 7.4 at 12 months (p=0.002). Across facilities, 50% had composite scores greater than the average score among reference facilities (7.4) at 12 months compared to none at baseline. Rapid facility surveys, stakeholder engagement, and information feedback can be used for gap analysis and resource allocation. This approach can achieve effective use of limited resources, improve facility readiness, and ensure consistency of facility capacity to provide quality care at the district level.
Iyer, Hari S.; Kamanzi, Emmanuel; Mugunga, Jean Claude; Finnegan, Karen; Uwingabiye, Alice; Shyaka, Edward; Niyonzima, Saleh; Hirschhorn, Lisa R.; Drobac, Peter C.
2015-01-01
Background While health systems strengthening (HSS) interventions are recommended by global health policy experts to improve population health in resource-limited settings, few examples exist of evaluations of HSS interventions conducted at the district level. In 2009, a partnership between Partners In Health (PIH), a non-governmental organization, and the Rwandan Ministry of Health (RMOH) was provided funds to implement and evaluate a district-level HSS intervention in two rural districts of Rwanda. Design The partnership provided limited funds to 14 health centers for targeted systems support in 2010; six others received support prior to the intervention (reference). RMOH health systems norms were mapped across the WHO HSS framework, scored from 0 to 10 and incorporated into a rapid survey assessing 11 domains of facility readiness. Stakeholder meetings allowed partnership leaders to review results, set priorities, and allocate resources. Investments included salary support, infrastructure improvements, medical equipment, and social support for patients. We compared facility domain scores from the start of the intervention to 12 months and tested for correlation between change in score and change in funding allocation to assess equity in our approach. Results We found significant improvements among intervention facilities from baseline to 12 months across several domains [infrastructure (+4, p=0.0001), clinical services (+1.2, p=0.03), infection and sanitation control (+0.6, p=0.03), medical equipment (+1.0, p=0.02), information use (+2, p=0.002)]. Composite score across domains improved from 6.2 at baseline to 7.4 at 12 months (p=0.002). Across facilities, 50% had composite scores greater than the average score among reference facilities (7.4) at 12 months compared to none at baseline. Conclusions Rapid facility surveys, stakeholder engagement, and information feedback can be used for gap analysis and resource allocation. This approach can achieve effective use of limited resources, improve facility readiness, and ensure consistency of facility capacity to provide quality care at the district level. PMID:26140729
Omondi Aduda, Dickens S; Ouma, Collins; Onyango, Rosebella; Onyango, Mathews; Bertrand, Jane
2015-01-01
Voluntary medical male circumcision (VMMC) service delivery is complex and resource-intensive. In Kenya's context there is still paucity of information on resource use vis-à-vis outputs as programs scale up. Knowledge of technical efficiency, productivity and potential sources of constraints is desirable to improve decision-making. To evaluate technical efficiency and productivity of VMMC service delivery in Nyanza in 2011/2012 using data envelopment analysis. Comparative process evaluation of facilities providing VMMC in Nyanza in 2011/2012 using output orientated data envelopment analysis. Twenty one facilities were evaluated. Only 1 of 7 variables considered (total elapsed operation time) significantly improved from 32.8 minutes (SD 8.8) in 2011 to 30 minutes (SD 6.6) in 2012 (95%CI = 0.0350-5.2488; p = 0.047). Mean scale technical efficiency significantly improved from 91% (SD 19.8) in 2011 to 99% (SD 4.0) in 2012 particularly among outreach compared to fixed service delivery facilities (CI -31.47959-4.698508; p = 0.005). Increase in mean VRS technical efficiency from 84% (SD 25.3) in 2011 and 89% (SD 25.1) in 2012 was not statistically significant. Benchmark facilities were #119 and #125 in 2011 and #103 in 2012. Malmquist Productivity Index (MPI) at fixed facilities declined by 2.5% but gained by 4.9% at outreach ones by 2012. Total factor productivity improved by 83% (p = 0.032) in 2012, largely due to progress in technological efficiency by 79% (p = 0.008). Significant improvement in scale technical efficiency among outreach facilities in 2012 was attributable to accelerated activities. However, ongoing pure technical inefficiency requires concerted attention. Technological progress was the key driver of service productivity growth in Nyanza. Incorporating service-quality dimensions and using stepwise-multiple criteria in performance evaluation enhances comprehensiveness and validity. These findings highlight site-level resource use and sources of variations in VMMC service productivity, which are important for program planning.
Changes in dynamics of accommodation after accommodative facility training in myopes and emmetropes.
Allen, Peter M; Charman, W Neil; Radhakrishnan, Hema
2010-05-12
This study evaluates the effect of accommodative facility training in myopes and emmetropes. Monocular accommodative facility was measured in nine myopes and nine emmetropes for distance and near. Subjective facility was recorded with automated flippers and objective measurements were simultaneously taken with a PowerRefractor. Accommodative facility training (a sequence of 5 min monocular right eye, 5 min monocular left eye, 5 min binocular) was given on three consecutive days and facility was re-assessed on the fifth day. The results showed that training improved the facility rate in both groups. The improvement in facility rates were linked to the time constants and peak velocity of accommodation. Some changes in amplitude seen in emmetropes indicate an improvement in facility rate at the expense of an accurate accommodation response. Copyright 2010 Elsevier Ltd. All rights reserved.
Takata, Miki; Fukushima, Kazuyo; Kino-Kimata, Noriko; Nagao, Norio; Niwa, Chiaki; Toda, Tatsuki
2012-08-15
In Japan, a revised Food Recycling Law went into effect in 2007 to promote a "recycling loop" that requires food industries to purchase farm products that are grown using food waste-derived compost/animal feed. To realize and expand food recycling, it is necessary to evaluate how the recycling facilities work in the recycling loop. The purpose of this study is to assess the environmental and economic efficiency of the food recycling facilities that are involved in the recycling loop, which are also known as looped facilities. The global warming potential and running cost of five looped facilities were evaluated by LCA (life cycle assessment) and LCC (life cycle cost) approaches: machine integrated compost, windrow compost, liquid feed, dry feed, and bio-gasification. The LCA results showed low total GHG (greenhouse gas) emissions of -126 and -49 kg-CO(2)/t-waste, respectively, for dry feed and bio-gasification facilities, due to a high substitution effect. The LCC study showed a low running cost for composting facilities of -15,648 and -18,955 yen/t-waste, respectively, due to high revenue from the food waste collection. It was found that the mandatory reporting of food waste emitters to the government increased collection fees; however, the collection fee in animal feed facilities was relatively low because food waste was collected at a low price or nutritious food waste was purchased to produce quality feed. In the characterisation survey of various treatment methods, the composting facilities showed a relatively low environmental impact and a high economic efficiency. Animal feed facilities had a wide distribution of the total GHG emissions, depending on both the energy usage during the drying process and the substitution effect, which were related to the water content of the food waste and the number of recycled products. In comparison with incineration, the majority of the food recycling facilities showed low GHG emissions and economic effectiveness. This paper also reported on the effects of recycling loops by comparing looped and non-looped animal feed facilities, and confirmed that the looped facilities were economically effective, due to an increased amount of food waste collection. Copyright © 2012 Elsevier B.V. All rights reserved.
Supplemental multilayer insulation research facility
NASA Technical Reports Server (NTRS)
Dempsey, P. J.; Stochl, R. J.
1995-01-01
The Supplemental Multilayer Insulation Research Facility (SMIRF) provides a small scale test bed for conducting cryogenic experiments in a vacuum environment. The facility vacuum system is capable of simulating a Space Shuttle launch pressure profile as well as providing a steady space vacuum environment of 1.3 x 10(exp -4) Newton/sq meter (1 x 10(exp -6) torr). Warm side boundary temperatures can be maintained constant between 111 K (200 R) and 361 K (650 R) using a temperature controlled shroud. The shroud can also simulate a typical lunar day-night temperature profile. The test hardware consists of a cryogenic calorimeter supported by the lid of the vacuum chamber. A 0.45 cu meter (120 gallon) vacuum jacketed storage/supply tank is available for conditioning the cryogen prior to use in the calorimeter. The facility was initially designed to evaluate the thermal performance of insulation systems for long-term storage in space. The facility has recently been used to evaluate the performance of various new insulation systems for LH2 and LN2 ground storage dewars.
Evaluation of an Indoor Sonic Boom Subjective Test Facility at NASA Langley Research Center
NASA Technical Reports Server (NTRS)
Loubeau, Alexandra; Rathsam, Jonathan; Klos, Jacob
2011-01-01
A sonic boom simulator at NASA Langley Research Center has been constructed for research on human response to low-amplitude sonic booms heard indoors. Research in this facility will ultimately lead to development of a psychoacoustic model for single indoor booms. The first subjective test was designed to explore indoor human response to variations in sonic boom rise time and amplitude. Another goal was to identify loudness level variability across listener locations within the facility. Finally, the test also served to evaluate the facility as a laboratory research tool for studying indoor human response to sonic booms. Subjects listened to test sounds and were asked to rate their annoyance relative to a reference boom. Measurements of test signals were conducted for objective analysis and correlation with subjective responses. Results confirm the functionality of the facility and effectiveness of the test methods and indicate that loudness level does not fully describe indoor annoyance to the selected sonic boom signals.
MacDonald, J K; Boase, J; Stewart, L K; Alexander, E R; Solomon, S L; Cordell, R L
1997-12-01
The purpose of this study was to develop and evaluate models for public health surveillance of illnesses among children in out-of-home child care facilities. Between July 1992 and March 1994, 200 Seattle-King County child care facilities participated in active or enhanced passive surveillance, or both. Reporting was based on easily recognized signs, symptoms, and sentinel events. Published criteria were used in evaluating surveillance effectiveness, and notifiable disease reporting of participating and nonparticipating facilities was compared. Neither surveillance model was well accepted by child care providers. Enhanced passive and active surveillance had comparable sensitivity. Reporting delays and the large amount of time needed for data entry led to problems with timeliness, especially in terms of written reporting during active surveillance. Widespread active public health surveillance in child care facilities is not feasible for most local health departments. Improvements in public health surveillance in child care settings will depend on acceptability to providers.
Quality of physical resources of health facilities in Indonesia: a panel study 1993-2007.
Diana, Aly; Hollingworth, Samantha A; Marks, Geoffrey C
2013-10-01
The merits of mixed public and private health systems are debated. Although private providers have become increasingly important in the Indonesian health system, there is no comprehensive assessment of the quality of private facilities. This study examined the quality of physical resources of public and private facilities in Indonesia from 1993 to 2007. Data from the Indonesian Family Life Surveys in 1993, 1997, 2000 and 2007 were used to evaluate trends in the quality of physical resources for public and private facilities, stratified by urban/rural areas and Java-Bali/outer Java-Bali regions. The quality of six categories of resources was measured using an adapted MEASURE Evaluation framework. Overall quality was moderate, but higher in public than in private health facilities in all years regardless of the region. The higher proportion of nurses and midwives in private practice was a determinant of scope of services and facilities available. There was little improvement in quality of physical resources following decentralization. Despite significant increases in public investment in health between 2000 and 2006 and the potential benefits of decentralization (2001), the quality of both public and private health facilities in Indonesia did not improve significantly between 1993 and 2007. As consumers commonly believe the quality is better in private facilities and are increasingly using them, it is essential to improve quality in both private and public facilities. Implementation of minimum standards and effective partnerships with private practice are considered important.
40 CFR 265.94 - Recordkeeping and reporting.
Code of Federal Regulations, 2012 CFR
2012-07-01
... required in § 265.92(e), and the evaluations required in § 265.93(b) throughout the active life of the... found in the upgradient wells, in accordance with § 265.93(c)(1). During the active life of the facility... requirements of § 265.93(d)(3), throughout the active life of the facility, and, for disposal facilities...
40 CFR 265.94 - Recordkeeping and reporting.
Code of Federal Regulations, 2010 CFR
2010-07-01
... required in § 265.92(e), and the evaluations required in § 265.93(b) throughout the active life of the... found in the upgradient wells, in accordance with § 265.93(c)(1). During the active life of the facility... requirements of § 265.93(d)(3), throughout the active life of the facility, and, for disposal facilities...
A Framework for Measuring Student and Staff Satisfaction with University Campus Facilities
ERIC Educational Resources Information Center
Kärnä, Sami; Julin, Päivi
2015-01-01
Purpose: The purpose of the study is to evaluate and discuss the extent of the satisfaction as perceived by the students and staff towards university facilities and services in two campuses in Finland. The aim is to analyse which facility-related factors have the greatest impacts on students' and staff's overall satisfaction.…
ERIC Educational Resources Information Center
Ainley, John G.
This report is a study conducted by the Australian Council for Educational Research to evaluate the influence of science material resources, provided under the Australian Science Facilities Program, on science education in Australia. Under the Australian Science Facilities Program some $123 million was spent, between July 1964 and June 1975, on…
Urban Rail Supporting Technology Program Fiscal Year 1974 Year End Summary
DOT National Transportation Integrated Search
1975-03-01
Major areas include program management, technical support and application engineering, facilities development, test and evaluation, and technology development. Specific technical discussion includes track measurement systems; UMTA facilities developm...
A carbon fiber exposure test facility and instrumentation
NASA Technical Reports Server (NTRS)
Newcomb, A. L., Jr.
1980-01-01
A facility to evaluate the risk associated with the exposure of electrical and electronic equipment to airborne carbon/graphite fibers was constructed. A wide variety of instrumentation is described and illustrated.
Seña, Arlene C; Moorman, Anne; Njord, Levi; Williams, Roxanne E; Colborn, James; Khudyakov, Yury; Drobenuic, Jan; Xia, Guo-Liang; Wood, Hattie; Moore, Zack
2013-07-01
Acute hepatitis B virus (HBV) infections have been reported in long-term care facilities (LTCFs), primarily associated with infection control breaks during assisted blood glucose monitoring. We investigated HBV outbreaks that occurred in separate skilled nursing facilities (SNFs) to determine factors associated with transmission. Outbreak investigation with case-control studies. Two SNFs (facilities A and B) in Durham, North Carolina, during 2009-2010. Residents with acute HBV infection and controls randomly selected from HBV-susceptible residents during the outbreak period. After initial cases were identified, screening was offered to all residents, with repeat testing 3 months later for HBV-susceptible residents. Molecular testing was performed to assess viral relatedness. Infection control practices were observed. Case-control studies were conducted to evaluate associations between exposures and acute HBV infection in each facility. Six acute HBV cases were identified in each SNF. Viral phylogenetic analysis revealed a high degree of HBV relatedness within, but not between, facilities. No evaluated exposures were significantly associated with acute HBV infection in facility A; those associated with infection in facility B (all odds ratios >20) included injections, hospital or emergency room visits, and daily blood glucose monitoring. Observations revealed absence of trained infection control staff at facility A and suboptimal hand hygiene practices during blood glucose monitoring and insulin injections at facility B. These outbreaks underscore the vulnerability of LTCF residents to acute HBV infection, the importance of surveillance and prompt investigation of incident cases, and the need for improved infection control education to prevent transmission.
Smets, Tinne; Onwuteaka-Philipsen, Bregje B D; Miranda, Rose; Pivodic, Lara; Tanghe, Marc; van Hout, Hein; Pasman, Roeline H R W; Oosterveld-Vlug, Mariska; Piers, Ruth; Van Den Noortgate, Nele; Wichmann, Anne B; Engels, Yvonne; Vernooij-Dassen, Myrra; Hockley, Jo; Froggatt, Katherine; Payne, Sheila; Szczerbińska, Katarzyna; Kylänen, Marika; Leppäaho, Suvi; Barańska, Ilona; Gambassi, Giovanni; Pautex, Sophie; Bassal, Catherine; Deliens, Luc; Van den Block, Lieve
2018-03-12
Several studies have highlighted the need for improvement in palliative care delivered to older people long-term care facilities. However, the available evidence on how to improve palliative care in these settings is weak, especially in Europe. We describe the protocol of the PACE trial aimed to 1) evaluate the effectiveness and cost-effectiveness of the 'PACE Steps to Success' palliative care intervention for older people in long-term care facilities, and 2) assess the implementation process and identify facilitators and barriers for implementation in different countries. We will conduct a multi-facility cluster randomised controlled trial in Belgium, Finland, Italy, the Netherlands, Poland, Switzerland and England. In total, 72 facilities will be randomized to receive the 'Pace Steps to Success intervention' or to 'care as usual'. Primary outcome at resident level: quality of dying (CAD-EOLD); and at staff level: staff knowledge of palliative care (Palliative Care Survey). resident's quality of end-of-life care, staff self-efficacy, self-perceived educational needs, and opinions on palliative care. Economic outcomes: direct costs and quality-adjusted life years (QALYs). Measurements are performed at baseline and after the intervention. For the resident-level outcomes, facilities report all deaths of residents in and outside the facilities over a previous four-month period and structured questionnaires are sent to (1) the administrator, (2) staff member most involved in care (3) treating general practitioner, and (4) a relative. For the staff-level outcomes, all staff who are working in the facilities are asked to complete a structured questionnaire. A process evaluation will run alongside the effectiveness evaluation in the intervention group using the RE-AIM framework. The lack of high quality trials in palliative care has been recognized throughout the field of palliative care research. This cross-national cluster RCT designed to evaluate the impact of the palliative care intervention for long-term care facilities 'PACE Steps to Success' in seven countries, will provide important evidence concerning the effectiveness as well as the preconditions for optimal implementation of palliative care in nursing homes, and this within different health care systems. The study is registered at www.isrctn.com - ISRCTN14741671 (FP7-HEALTH-2013-INNOVATION-1 603111) Registration date: July 30, 2015.
Building 211 cyclotron characterization survey report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-03-30
The Building 211 Cyclotron Characterization Survey includes an assessment of the radioactive and chemical inventory of materials stored within the facility; an evaluation of the relative distribution of accelerator-produced activation products within various cyclotron components and adjacent structures; measurement of the radiation fields throughout the facility; measurement and assessment of internal and external radioactive surface contamination on various equipment, facility structures, and air-handling systems; and an assessment of lead (Pb) paint and asbestos hazards within the facility.
NASA Astrophysics Data System (ADS)
Theveneau, P.; Baker, R.; Barrett, R.; Beteva, A.; Bowler, M. W.; Carpentier, P.; Caserotto, H.; de Sanctis, D.; Dobias, F.; Flot, D.; Guijarro, M.; Giraud, T.; Lentini, M.; Leonard, G. A.; Mattenet, M.; McCarthy, A. A.; McSweeney, S. M.; Morawe, C.; Nanao, M.; Nurizzo, D.; Ohlsson, S.; Pernot, P.; Popov, A. N.; Round, A.; Royant, A.; Schmid, W.; Snigirev, A.; Surr, J.; Mueller-Dieckmann, C.
2013-03-01
Automation and advances in technology are the key elements in addressing the steadily increasing complexity of Macromolecular Crystallography (MX) experiments. Much of this complexity is due to the inter-and intra-crystal heterogeneity in diffraction quality often observed for crystals of multi-component macromolecular assemblies or membrane proteins. Such heterogeneity makes high-throughput sample evaluation an important and necessary tool for increasing the chances of a successful structure determination. The introduction at the ESRF of automatic sample changers in 2005 dramatically increased the number of samples that were tested for diffraction quality. This "first generation" of automation, coupled with advances in software aimed at optimising data collection strategies in MX, resulted in a three-fold increase in the number of crystal structures elucidated per year using data collected at the ESRF. In addition, sample evaluation can be further complemented using small angle scattering experiments on the newly constructed bioSAXS facility on BM29 and the micro-spectroscopy facility (ID29S). The construction of a second generation of automated facilities on the MASSIF (Massively Automated Sample Screening Integrated Facility) beam lines will build on these advances and should provide a paradigm shift in how MX experiments are carried out which will benefit the entire Structural Biology community.
DISPOSITION PATHS FOR ROCKY FLATS GLOVEBOXES: EVALUATING OPTIONS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lobdell, D.; Geimer, R.; Larsen, P.
2003-02-27
The Kaiser-Hill Company, LLC has the responsibility for closure activities at the Rocky Flats Environmental Technology Site (RFETS). One of the challenges faced for closure is the disposition of radiologically contaminated gloveboxes. Evaluation of the disposition options for gloveboxes included a detailed analysis of available treatment capabilities, disposal facilities, and lifecycle costs. The Kaiser-Hill Company, LLC followed several processes in determining how the gloveboxes would be managed for disposition. Currently, multiple disposition paths have been chosen to accommodate the needs of the varying styles and conditions of the gloveboxes, meet the needs of the decommissioning team, and to best managemore » lifecycle costs. Several challenges associated with developing a disposition path that addresses both the radiological and RCRA concerns as well as offering the most cost-effective solution were encountered. These challenges included meeting the radiological waste acceptance criteria of available disposal facilities, making a RCRA determination, evaluating treatment options and costs, addressing void requirements associated with disposal, and identifying packaging and transportation options. The varying disposal facility requirements affected disposition choices. Facility conditions that impacted decisions included radiological and chemical waste acceptance criteria, physical requirements, and measurement for payment options. The facility requirements also impacted onsite activities including management strategies, decontamination activities, and life-cycle cost.« less
Extreme winds and tornadoes: an overview
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDonald, J.R.
1985-01-01
The objective of this course on extreme winds, hurricanes and tornadoes is to provide an overview of these natural phenomenon from the perspective of design of new buildings and structures or the evaluation of existing ones. Information is directly applicable to design and evaluation processes. The premise is that the facility under consideration, which may consist of various buildings, structures, processing equipment, stacks, ventilation ducts, etc., can be classified into certain categories, depending on the importance of the mission performed in the facility or the hazard that is presented by the particular operation. Having classified the facility into an appropriatemore » category will automatically define certain design goals for the facility. The design goals are then met by selecting a design wind speed that is appropriate for the specified exceedance probability and by following certain specified design procedures. The problem then is to determine appropriate wind loads and other applicable loads, including dead loads, live loads, seismic loads and other loads that may act on the structures. The design process can then proceed in the usual manner. In the case of existing facilities the strengths of the various structural elements, subsystems and systems are evaluated and these strengths are related to wind speeds that would result in failure to meet the design goals. 12 refs.« less
An Evaluation of Red Shoulders as a Bicycle and Pedestrian Facility
Hunter, William W.
1999-01-01
Use of color has been popular in European bicycle facilities. As an innovative treatment, the community of Tavares, FL decided to add one mile of shoulders to a scenic roadway and paint the shoulders red to emphasize their use as a bicycle facility. The red shoulders were evaluated by examining: (1) motor vehicle speed data collected before and after the addition of the red shoulders, (2) the amount of use of the shoulder by bicyclists, (3) the lateral positioning of bicyclists being passed by motor vehicles, (4) the amount and severity of vehicular encroachment into the opposing lane of travel, and (5) conflicts between bicycles and motor vehicles.
Source term model evaluations for the low-level waste facility performance assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yim, M.S.; Su, S.I.
1995-12-31
The estimation of release of radionuclides from various waste forms to the bottom boundary of the waste disposal facility (source term) is one of the most important aspects of LLW facility performance assessment. In this work, several currently used source term models are comparatively evaluated for the release of carbon-14 based on a test case problem. The models compared include PRESTO-EPA-CPG, IMPACTS, DUST and NEFTRAN-II. Major differences in assumptions and approaches between the models are described and key parameters are identified through sensitivity analysis. The source term results from different models are compared and other concerns or suggestions are discussed.
Annual Summary of the Integrated Disposal Facility Performance Assessment 2011
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lehman, L. L.
2012-03-12
An annual summary of the adequacy of the Hanford Immobilized Low-Activity Waste (ILAW) Performance Assessment (PA) is required each year (DOE O 435.1 Chg 1,1 DOE M 435.1-1 Chg 1,2 DOE/ORP-2000-013). The most recently approved PA is DOE/ORP-2000-24.4 The ILAW PA evaluated the adequacy of the ILAW disposal facility, now referred to as the Integrated Disposal Facility (IDF), for the safe disposal of vitrified Hanford Site tank waste. More recently, a preliminary evaluation for the disposal of offsite low-level waste and mixed low-level waste was considered in RPP-1583.
NASA Technical Reports Server (NTRS)
Killian, D. A.; Menninger, F. J.; Gorman, T.; Glenn, P.
1988-01-01
The Technical Facilities Controller is a microprocessor-based energy management system that is to be implemented in the Deep Space Network facilities. This system is used in conjunction with facilities equipment at each of the complexes in the operation and maintenance of air-conditioning equipment, power generation equipment, power distribution equipment, and other primary facilities equipment. The implementation of the Technical Facilities Controller was completed at the Goldstone Deep Space Communications Complex and is now operational. The installation completed at the Goldstone Complex is described and the utilization of the Technical Facilities Controller is evaluated. The findings will be used in the decision to implement a similar system at the overseas complexes at Canberra, Australia, and Madrid, Spain.
Guidance: Use of Contract Inspectors for EPA's Federal Facility Compliance Inspections/Evaluations
This guidance clarifies that properly trained authorized and federally credentialed EPA contract inspectors can perform compliance inspections at federal facilities under the CWA, RCRA, TSCA, OPA and the SDWA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stickney, R.G.
This report presents the results of a systematic evaluation conducted to identify miscellaneous TWRS facilities, tanks and components with potential needed authorization basis upgrades. It provides the Authorization Basis upgrade plan for those miscellaneous TWRS facilities, tanks and components identified.
This manual is intended as a source document for individuals responsible for improving the performance of an existing, non-complying wastewater treatment facility. Described are: 1) methods to evaluate an existing facility's capability to achieve improved performance, 2) a ...
NASA Technical Reports Server (NTRS)
Hozman, Aron D.; Hughes, William O.
2014-01-01
The exposure of a customer's aerospace test-article to a simulated acoustic launch environment is typically performed in a reverberant acoustic test chamber. The acoustic pre-test runs that will ensure that the sound pressure levels of this environment can indeed be met by a test facility are normally performed without a test-article dynamic simulator of representative acoustic absorption and size. If an acoustic test facility's available acoustic power capability becomes maximized with the test-article installed during the actual test then the customer's environment requirement may become compromised. In order to understand the risk of not achieving the customer's in-tolerance spectrum requirement with the test-article installed, an acoustic power margin evaluation as a function of frequency may be performed by the test facility. The method for this evaluation of acoustic power will be discussed in this paper. This method was recently applied at the NASA Glenn Research Center Plum Brook Station's Reverberant Acoustic Test Facility for the SpaceX Falcon 9 Payload Fairing acoustic test program.
NASA Technical Reports Server (NTRS)
Hozman, Aron D.; Hughes, William O.
2014-01-01
The exposure of a customers aerospace test-article to a simulated acoustic launch environment is typically performed in a reverberant acoustic test chamber. The acoustic pre-test runs that will ensure that the sound pressure levels of this environment can indeed be met by a test facility are normally performed without a test-article dynamic simulator of representative acoustic absorption and size. If an acoustic test facilitys available acoustic power capability becomes maximized with the test-article installed during the actual test then the customers environment requirement may become compromised. In order to understand the risk of not achieving the customers in-tolerance spectrum requirement with the test-article installed, an acoustic power margin evaluation as a function of frequency may be performed by the test facility. The method for this evaluation of acoustic power will be discussed in this paper. This method was recently applied at the NASA Glenn Research Center Plum Brook Stations Reverberant Acoustic Test Facility for the SpaceX Falcon 9 Payload Fairing acoustic test program.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martino, C.
An evaluation of the previous Chemical Processing Cell (CPC) testing was performed to determine whether the planned concurrent operation, or “coupled” operations, of the Defense Waste Processing Facility (DWPF) with the Salt Waste Processing Facility (SWPF) has been adequately covered. Tests with the nitricglycolic acid flowsheet, which were both coupled and uncoupled with salt waste streams, included several tests that required extended boiling times. This report provides the evaluation of previous testing and the testing recommendation requested by Savannah River Remediation. The focus of the evaluation was impact on flammability in CPC vessels (i.e., hydrogen generation rate, SWPF solvent components,more » antifoam degradation products) and processing impacts (i.e., acid window, melter feed target, rheological properties, antifoam requirements, and chemical composition).« less
Designing Facilities for Collaborative Operations
NASA Technical Reports Server (NTRS)
Norris, Jeffrey; Powell, Mark; Backes, Paul; Steinke, Robert; Tso, Kam; Wales, Roxana
2003-01-01
A methodology for designing operational facilities for collaboration by multiple experts has begun to take shape as an outgrowth of a project to design such facilities for scientific operations of the planned 2003 Mars Exploration Rover (MER) mission. The methodology could also be applicable to the design of military "situation rooms" and other facilities for terrestrial missions. It was recognized in this project that modern mission operations depend heavily upon the collaborative use of computers. It was further recognized that tests have shown that layout of a facility exerts a dramatic effect on the efficiency and endurance of the operations staff. The facility designs (for example, see figure) and the methodology developed during the project reflect this recognition. One element of the methodology is a metric, called effective capacity, that was created for use in evaluating proposed MER operational facilities and may also be useful for evaluating other collaboration spaces, including meeting rooms and military situation rooms. The effective capacity of a facility is defined as the number of people in the facility who can be meaningfully engaged in its operations. A person is considered to be meaningfully engaged if the person can (1) see, hear, and communicate with everyone else present; (2) see the material under discussion (typically data on a piece of paper, computer monitor, or projection screen); and (3) provide input to the product under development by the group. The effective capacity of a facility is less than the number of people that can physically fit in the facility. For example, a typical office that contains a desktop computer has an effective capacity of .4, while a small conference room that contains a projection screen has an effective capacity of around 10. Little or no benefit would be derived from allowing the number of persons in an operational facility to exceed its effective capacity: At best, the operations staff would be underutilized; at worst, operational performance would deteriorate. Elements of this methodology were applied to the design of three operations facilities for a series of rover field tests. These tests were observed by human-factors researchers and their conclusions are being used to refine and extend the methodology to be used in the final design of the MER operations facility. Further work is underway to evaluate the use of personal digital assistant (PDA) units as portable input interfaces and communication devices in future mission operations facilities. A PDA equipped for wireless communication and Ethernet, Bluetooth, or another networking technology would cost less than a complete computer system, and would enable a collaborator to communicate electronically with computers and with other collaborators while moving freely within the virtual environment created by a shared immersive graphical display.
Davey, Sanjeev; Raghav, Santosh Kumar; Singh, Jai Vir; Davey, Anuradha; Singh, Nirankar
2015-01-01
Background: The evaluation of primary healthcare services provided by health training centers of a private medical college has not been studied in comparison with government health facilities in Indian context. Data envelopment analysis (DEA) is one such technique of operations research, which can be used on health facilities for identifying efficient operating practices and strategies for relatively efficient or inefficient health centers by calculating their efficiency scores. Materials and Methods: This study was carried out by DEA technique by using basic radial models (constant ratio to scale (CRS)) in linear programming via DEAOS free online Software among four decision making units (DMUs; by comparing efficiency of two private health centers of a private medical college of India with two public health centers) in district Muzaffarnagar of state Uttar Pradesh. The input and output records of all these health facilities (two from private and two from Government); for 6 months duration from 1st Jan 2014 to 1st July 2014 was taken for deciding their efficiency scores. Results: The efficiency scores of primary healthcare services in presence of doctors (100 vs 30%) and presence of health staff (100 vs 92%) were significantly better from government health facilities as compared to private health facilities (P < 0.0001). Conclusions: The evaluation of primary healthcare services delivery by DEA technique reveals that the government health facilities group were more efficient in delivery of primary healthcare services as compared to private training health facilities group, which can be further clarified in by more in-depth studies in future. PMID:26435598
EP of a Different Class: The Challenges of Testing for MW Missions
2012-07-20
that the pumping capacity of the Large Vacuum Test Facility (LVTF) at PEPL (Figure 3) at 520,000 l/s on air makes it most suitable for initial checkout...evaluation of the thruster. NASA Glenn Research Center’s Vacuum Facility 5 (VF5) (Figure 4), with its increased pumping speed of 3,500,000 l/s on air...reader to Dr. Dan Goebel’s IEPC 2011 paper.41 IV. Facility Selection and Preparation Facility Size and Pumping High T/P thruster testing
78 FR 79499 - Agency Information Collection Activities: Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-30
... descriptive and may include, for example, lists of successful proposal and users, the characteristics of... facilities, and to evaluate the progress of the program. Estimate of Burden: 790 hours per facility for three...
78 FR 79012 - Agency Information Collection Activities: Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-27
... descriptive and may include, for example, lists of successful proposal and users, the characteristics of... facilities, and to evaluate the progress of the program. Estimate of Burden: 790 hours per facility for three...
78 FR 79013 - Agency Information Collection Activities: Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-27
... descriptive and may include, for example, lists of successful proposal and users, the characteristics of... facilities, and to evaluate the progress of the program. Estimate of Burden: 790 hours per facility for three...
Inspection of KCBX Terminals Company, Chicago, Illinois – May 10, 2012
EPA inspected the petroleum coke (petcoke) facility to investigate a coal dust complaint, and evaluate for compliance with the facility's Federally Enforceable State Operating Permit (FESOP) and the Clean Air Act.
23 CFR 771.118 - FTA categorical exclusions
Code of Federal Regulations, 2014 CFR
2014-04-01
...) Acquisition, installation, operation, evaluation, replacement, and improvement of discrete utilities and... activities; rehabilitation of public transportation buildings, structures, or facilities; retrofitting for... transportation vehicles, facilities or structures, or upgrading to current standards. (6) Acquisition or transfer...
23 CFR 771.118 - FTA categorical exclusions
Code of Federal Regulations, 2013 CFR
2013-04-01
...) Acquisition, installation, operation, evaluation, replacement, and improvement of discrete utilities and... activities; rehabilitation of public transportation buildings, structures, or facilities; retrofitting for... transportation vehicles, facilities or structures, or upgrading to current standards. (6) Acquisition or transfer...
Core commands across airway facilities systems.
DOT National Transportation Integrated Search
2003-05-01
This study takes a high-level approach to evaluate computer systems without regard to the specific method of : interaction. This document analyzes the commands that Airway Facilities (AF) use across different systems and : the meanings attributed to ...
DUF6 Conversion Facility EIS Alternatives
in the Depleted UF6 Conversion Facility EISs. Proposed Action The proposed action evaluated in each Action Alternative No Action Alternative. Under the "no action" alternative, cylinder
10 CFR 50.83 - Release of part of a power reactor facility or site for unrestricted use.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Release of part of a power reactor facility or site for... of a power reactor facility or site for unrestricted use. (a) Prior written NRC approval is required... release. Nuclear power reactor licensees seeking NRC approval shall— (1) Evaluate the effect of releasing...
10 CFR 50.83 - Release of part of a power reactor facility or site for unrestricted use.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Release of part of a power reactor facility or site for... of a power reactor facility or site for unrestricted use. (a) Prior written NRC approval is required... release. Nuclear power reactor licensees seeking NRC approval shall— (1) Evaluate the effect of releasing...
ERIC Educational Resources Information Center
Natale, Ruby; Camejo, Stephanie; Sanders, Lee M.
2016-01-01
Obesity is a significant public health issue affecting even our youngest children. Given that a significant amount of young children are enrolled in child care, the goal of this project was to evaluate the effectiveness of a child care facility-based obesity prevention program. Over 1,000 facilities participated in the study. The intervention…
NoFoam Unit Installation, Evaluation and Operations Manual
2003-03-10
Aqueous Film Forming Foam ( AFFF ) liquid concentrate in their fleet do not have the facilities...NoFoam Unit using AFRL vehicles and facilities. Currently, the majority of Fire Departments that use 3% Aqueous Film Forming Foam ( AFFF ) liquid...Departments that have ARFF vehicles that use 3% Aqueous Film Forming Foam ( AFFF ) liquid concentrate in their fleet do not have the facilities
2008-03-01
1 . Maintenance Practices Influence Service Life .......................................................... 11 2 . Expectations or Standards May...BRB, 1991, p. 1 - 2 ) Additionally, public sector organizations typically have a larger inventory of facilities to maintain, making asset management...questions were answered. 1 . What are the long term causes and effects of under-funding the maintenance of facilities? 2 . What methods currently
EVA Training and Development Facilities
NASA Technical Reports Server (NTRS)
Cupples, Scott
2016-01-01
Overview: Vast majority of US EVA (ExtraVehicular Activity) training and EVA hardware development occurs at JSC; EVA training facilities used to develop and refine procedures and improve skills; EVA hardware development facilities test hardware to evaluate performance and certify requirement compliance; Environmental chambers enable testing of hardware from as large as suits to as small as individual components in thermal vacuum conditions.
Studies of Transgenic Mosquitoes in Disease-Endemic Countries: Preparation of Containment Facilities
Mutunga, James Mutuku; Diabaté, Abdoulaye; Namountougou, Moussa; Coulibaly, Mamadou B.; Sylla, Lakamy; Kayondo, Jonathan; Balyesima, Victor; Clark, Lorna; Benedict, Mark Q.; Raymond, Peter
2018-01-01
Abstract Novel approaches to area-wide control of vector species offer promise as additional tools in the fight against vectored diseases. Evaluation of transgenic insect strains aimed at field population control in disease-endemic countries may involve international partnerships and should be done in a stepwise approach, starting with studies in containment facilities. The preparations of both new-build and renovated facilities are described, including working with local and national regulations regarding land use, construction, and biosafety requirements, as well as international guidance to fill any gaps in regulation. The examples given are for containment categorization at Arthropod Containment Level 2 for initial facility design, classification of wastes, and precautions during shipping. Specific lessons were derived from preparations to evaluate transgenic (non-gene drive) mosquitoes in West and East African countries. Documented procedures and the use of a non-transgenic training strain for trial shipments and culturing were used to develop competence and confidence among the African facility staff, and along the chain of custody for transport. This practical description is offered to support other research consortia or institutions preparing containment facilities and operating procedures in conditions where research on transgenic insects is at an early stage. PMID:29337662
Quinlan, M Megan; Mutunga, James Mutuku; Diabaté, Abdoulaye; Namountougou, Moussa; Coulibaly, Mamadou B; Sylla, Lakamy; Kayondo, Jonathan; Balyesima, Victor; Clark, Lorna; Benedict, Mark Q; Raymond, Peter
2018-01-01
Novel approaches to area-wide control of vector species offer promise as additional tools in the fight against vectored diseases. Evaluation of transgenic insect strains aimed at field population control in disease-endemic countries may involve international partnerships and should be done in a stepwise approach, starting with studies in containment facilities. The preparations of both new-build and renovated facilities are described, including working with local and national regulations regarding land use, construction, and biosafety requirements, as well as international guidance to fill any gaps in regulation. The examples given are for containment categorization at Arthropod Containment Level 2 for initial facility design, classification of wastes, and precautions during shipping. Specific lessons were derived from preparations to evaluate transgenic (non-gene drive) mosquitoes in West and East African countries. Documented procedures and the use of a non-transgenic training strain for trial shipments and culturing were used to develop competence and confidence among the African facility staff, and along the chain of custody for transport. This practical description is offered to support other research consortia or institutions preparing containment facilities and operating procedures in conditions where research on transgenic insects is at an early stage.
Free-standing health care facilities: financial arrangements, quality assurance and a pilot study
Lavis, J N; Lomas, J; Anderson, G M; Donner, A; Iscoe, N A; Gold, G; Craighead, J
1998-01-01
Free-standing health care facilities now deliver many diagnostic and therapeutic services formerly provided only in hospitals. The financial arrangements available to these facilities differ according to whether the services are uninsured or insured. For an uninsured service, such as cosmetic surgery, the patient pays a fee directly to the service provider. For an insured service, such as cataract surgery, the provincial government uses tax revenues to fund the facility by paying it a facility fee and remunerates the physician who provided the service with a professional fee. No comprehensive, proactive quality assurance efforts have been implemented for either these facilities or the clinical practice provided within them. A pilot study involving therapeutic facilities in Ontario has suggested that a large-scale quality improvement effort could be undertaken in these facilities and rigorously evaluated. PMID:9484263
Free-standing health care facilities: financial arrangements, quality assurance and a pilot study.
Lavis, J N; Lomas, J; Anderson, G M; Donner, A; Iscoe, N A; Gold, G; Craighead, J
1998-02-10
Free-standing health care facilities now deliver many diagnostic and therapeutic services formerly provided only in hospitals. The financial arrangements available to these facilities differ according to whether the services are uninsured or insured. For an uninsured service, such as cosmetic surgery, the patient pays a fee directly to the service provider. For an insured service, such as cataract surgery, the provincial government uses tax revenues to fund the facility by paying it a facility fee and remunerates the physician who provided the service with a professional fee. No comprehensive, proactive quality assurance efforts have been implemented for either these facilities or the clinical practice provided within them. A pilot study involving therapeutic facilities in Ontario has suggested that a large-scale quality improvement effort could be undertaken in these facilities and rigorously evaluated.
Capolongo, Stefano; Gola, Marco; di Noia, Michela; Nickolova, Maria; Nachiero, Dario; Rebecchi, Andrea; Settimo, Gaetano; Vittori, Gail; Buffoli, Maddalena
2016-01-01
Nowadays several rating systems exist for the evaluation of the sustainability of buildings, but often their focus is limited to environmental and efficiency aspects. Hospitals are complex constructions in which many variables affect hospital processes. Therefore, a research group has developed a tool for the evaluation of sustainability in healthcare facilities. The paper analyses social sustainability issues through a tool which evaluates users' perception from a the quality and well-being perspective. It presents a hierarchical structure composed of a criteria and indicators system which is organised through a weighing system calculated by using the Analytic Network Process. The output is the definition of a tool which evaluates how Humanisation, Comfort and Distribution criteria can affect the social sustainability of a building. Starting from its application, it is evident that the instrument enables the improvement of healthcare facilities through several design and organisational suggestions for achieving healing and sustainable architectures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McHugh, M.G.; Coleman, G.H.
2006-07-01
The contents of a safety basis (SB) are based upon the facility's purpose of operation, radiological inventory, and safety systems in place to mitigate any releases to the employees, general public and environment. Specifically, the radiological inventory is used for facility categorizations (e.g., Category 2, Category 3) and determining the material at risk used in the associated nuclear safety analysis calculations. Radiological inventory discrepancies, referred to as 'mismatches', have the potential to adversely impact the SB. This paper summarizes a process developed to: 1) identify these 'mismatches' based on a facility's radiological inventory, 2) categorize these 'mismatches' according to availablemore » data, and then 3) determine if these 'mismatches' yield either trivial or significant cumulative impacts on credited assumptions associated with a particular facility's SB. The two facilities evaluated for 'mismatches' were the K-1065 Complex and the Above Grade Storage Facility (AGSF). The randomly selected containers from each facility were obtained along with screening the radiological inventories found in the Waste Information Tracking System (WITS) database and the Request for Disposal (RFD) forms. Ideally, the radiological inventory, which is comprised of isotopic data for each container, is maintained in the WITS database. However, the RFD is the official repository record for isotopic data for each container. Historically, neither WITS nor the RFDs were required to contain isotopic data. Based on the WITS and RFD data, the containers were then categorized into five (5) separate conditions: Condition 1) Isotopic data in the RFD matches the isotopic data in WITS; Condition 2) Isotopic data in the RFD does not match the isotopic data in WITS; Condition 3) Isotopic data are in the RFD, but are not in WITS; Condition 4) No isotopic data in the RFD, but isotopic data are found in WITS; Condition 5) No isotopic data found in either the RFD or WITS. The results show trivial cumulative impacts (i.e., no inherent data biases) on credited assumptions associated with the K-1065 Complex and AGSF SBs. Recent random comparisons of WITS and RFDs continue to verify and validate that the administrative and procedural controls are adequate to ensure compliance with the SB for these facilities, thus providing a useful model for evaluating other facilities located at the Department of Energy's Oak Ridge Reservation (DOE-ORR). (authors)« less
The evaluation of ASOS for the Kennedy Space Center's Shuttle Landing Facility
NASA Technical Reports Server (NTRS)
Yersavich, Ann; Wheeler, Mark; Taylor, Gregory; Schumann, Robin; Manobianco, John
1994-01-01
This report documents the Applied Meteorology Unit's (AMU) evaluation of the effectiveness and utility of the Automated Surface Observing System (ASOS) in terms of spaceflight operations and user requirements. In particular, the evaluation determines which of the Shuttle Landing Facility (SLF) observation requirements can be satisfied by ASOS. This report also includes a summary of ASOS' background, current configuration and specifications, system performance, and the possible concepts of operations for use of ASOS at the SLF. This evaluation stems from a desire by the Air Force to determine if ASOS units could be used to reduce the cost of SLF meteorological observations.
Chenoweth, Carol E; Hines, Stephen C; Hall, Kendall K; Saran, Rajiv; Kalbfleisch, John D; Spencer, Teri; Frank, Kelly M; Carlson, Diane; Deane, Jan; Roys, Erik; Scholz, Natalie; Parrotte, Casey; Messana, Joseph M
2015-07-01
OBJECTIVE To observe patient care across hemodialysis facilities enrolled in the National Opportunity to Improve Infection Control in ESRD (end-stage renal disease) (NOTICE) project in order to evaluate adherence to evidence-based practices aimed at prevention of infection. SETTING AND PARTICIPANTS Thirty-four hemodialysis facilities were randomly selected from among 772 facilities in 4 end-stage renal disease participating networks. Facility selection was stratified on dialysis organization affiliation, size, socioeconomic status, and urban/rural status. MEASUREMENTS Trained infection control evaluators used an infection control worksheet to observe 73 distinct infection control practices at the hemodialysis facilities, from October 1, 2011, through January 31, 2012. RESULTS There was considerable variation in infection control practices across enrolled facilities. Overall adherence to recommended practices was 68% (range, 45%-92%) across all facilities. Overall adherence to expected hand hygiene practice was 72% (range, 10%-100%). Compliance to hand hygiene before and after procedures was high; however, during procedures hand hygiene compliance averaged 58%. Use of chlorhexidine as the specific agent for exit site care was 19% overall but varied from 0% to 35% by facility type. The 8 checklists varied in the frequency of perfect performance from 0% for meeting every item on the checklist for disinfection practices to 22% on the arteriovenous access practices at initiation. CONCLUSIONS Our findings suggest that there are many areas for improvement in hand hygiene and other infection prevention practices in end-stage renal disease. These NOTICE project findings will help inform the development of a larger quality improvement initiative at dialysis facilities.
Preliminary hazards analysis -- vitrification process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coordes, D.; Ruggieri, M.; Russell, J.
1994-06-01
This paper presents a Preliminary Hazards Analysis (PHA) for mixed waste vitrification by joule heating. The purpose of performing a PHA is to establish an initial hazard categorization for a DOE nuclear facility and to identify those processes and structures which may have an impact on or be important to safety. The PHA is typically performed during and provides input to project conceptual design. The PHA is then followed by a Preliminary Safety Analysis Report (PSAR) performed during Title 1 and 2 design. The PSAR then leads to performance of the Final Safety Analysis Report performed during the facility`s constructionmore » and testing. It should be completed before routine operation of the facility commences. This PHA addresses the first four chapters of the safety analysis process, in accordance with the requirements of DOE Safety Guidelines in SG 830.110. The hazards associated with vitrification processes are evaluated using standard safety analysis methods which include: identification of credible potential hazardous energy sources; identification of preventative features of the facility or system; identification of mitigative features; and analyses of credible hazards. Maximal facility inventories of radioactive and hazardous materials are postulated to evaluate worst case accident consequences. These inventories were based on DOE-STD-1027-92 guidance and the surrogate waste streams defined by Mayberry, et al. Radiological assessments indicate that a facility, depending on the radioactive material inventory, may be an exempt, Category 3, or Category 2 facility. The calculated impacts would result in no significant impact to offsite personnel or the environment. Hazardous materials assessment indicates that a Mixed Waste Vitrification facility will be a Low Hazard facility having minimal impacts to offsite personnel and the environment.« less
Tukey, Melissa H; Clark, Jack A; Bolton, Rendelle; Kelley, Michael J; Slatore, Christopher G; Au, David H; Wiener, Renda Soylemez
2016-10-01
To mitigate the potential harms of screening, professional societies recommend that lung cancer screening be conducted in multidisciplinary programs with the capacity to provide comprehensive care, from screening through pulmonary nodule evaluation to treatment of screen-detected cancers. The degree to which this standard can be met at the national level is unknown. To assess the readiness of clinical facilities in a national healthcare system for implementation of comprehensive lung cancer screening programs, as compared with the ideal described in policy recommendations. This was a cross-sectional, self-administered survey of staff pulmonologists in pulmonary outpatient clinics in Veterans Health Administration facilities. The facility-level response rate was 84.1% (106 of 126 facilities with pulmonary clinics); 88.7% of facilities showed favorable provider perceptions of the evidence for lung cancer screening, and 73.6% of facilities had a favorable provider-perceived local context for screening implementation. All elements of the policy-recommended infrastructure for comprehensive screening programs were present in 36 of 106 facilities (34.0%); the most common deficiencies were the lack of on-site positron emission tomography scanners or radiation oncology services. Overall, 26.5% of Veterans Health Administration facilities were ideally prepared for lung cancer screening implementation (44.1% if the policy recommendations for on-site positron emission tomography scanners and radiation oncology services were waived). Many facilities may be less than ideally positioned for the implementation of comprehensive lung cancer screening programs. To ensure safe, effective screening, hospitals may need to invest resources or coordinate care with facilities that can offer comprehensive care for screening through downstream evaluation and treatment of screen-detected cancers.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-12
...: Clarksville Facility. Location: Clarksville, Tennessee. Job Titles and/or Job Duties: Workers potentially..., Division of Compensation Analysis and Support, National Institute for Occupational Safety and Health, 4676...
Is My Facility a Good Candidate for CHP?
Learn if a facility is a good candidate for CHP by answering a list of questions, and access the CHP Spark Spread Estimator, a tool that helps evaluate a prospective CHP system for its potential economic feasibility.
NASA Reactor Facility Hazards Summary. Volume 2
NASA Technical Reports Server (NTRS)
1959-01-01
Supplements to volume 1 are presented herein. Included in these papers are information unavailable when volume 1 was written, an evaluation of the proposed nuclear facility, and answers to questions raised by the AEC concerning volume 1.
RETROFITTING CONTROL FACILITIES FOR WET WEATHER FLOW TREATMENT
Available technologies were evaluated to demonstrate the technical feasibility and cost-effectiveness of retrofitting existing facilities to handle wet-weather flow. Cost/benefit relationships were also compared to construction of new conventional control and treatment facilitie...
Validity of self-assessment in a quality improvement collaborative in Ecuador.
Hermida, Jorge; Broughton, Edward I; Miller Franco, Lynne
2011-12-01
Health care quality improvement (QI) efforts commonly use self-assessment to measure compliance with quality standards. This study investigates the validity of self-assessment of quality indicators. Cross sectional. A maternal and newborn care improvement collaborative intervention conducted in health facilities in Ecuador in 2005. Four external evaluators were trained in abstracting medical records to calculate six indicators reflecting compliance with treatment standards. About 30 medical records per month were examined at 12 participating health facilities for a total of 1875 records. The same records had already been reviewed by QI teams at these facilities (self-assessment). Overall compliance, agreement (using the Kappa statistic), sensitivity and specificity were analyzed. We also examined patterns of disagreement and the effect of facility characteristics on levels of agreement. External evaluators reported compliance of 69-90%, while self-assessors reported 71-92%, with raw agreement of 71-95% and Kappa statistics ranging from fair to almost perfect agreement. Considering external evaluators as the gold standard, sensitivity of self-assessment ranged from 90 to 99% and specificity from 48 to 86%. Simpler indicators had fewer disagreements. When disagreements occurred between self-assessment and external valuators, the former tended to report more positive findings in five of six indicators, but this tendency was not of a magnitude to change program actions. Team leadership, understanding of the tools and facility size had no overall impact on the level of agreement. When compared with external evaluation (gold standard), self-assessment was found to be sufficiently valid for tracking QI team performance. Sensitivity was generally higher than specificity. Simplifying indicators may improve validity.
Implementation research to improve quality of maternal and newborn health care, Malawi
Wilhelm, Danielle; Lohmann, Julia; Kambala, Christabel; Chinkhumba, Jobiba; Muula, Adamson S; De Allegri, Manuela
2017-01-01
Abstract Objective To evaluate the impact of a performance-based financing scheme on maternal and neonatal health service quality in Malawi. Methods We conducted a non-randomized controlled before and after study to evaluate the effects of district- and facility-level performance incentives for health workers and management teams. We assessed changes in the facilities’ essential drug stocks, equipment maintenance and clinical obstetric care processes. Difference-in-difference regression models were used to analyse effects of the scheme on adherence to obstetric care treatment protocols and provision of essential drugs, supplies and equipment. Findings We observed 33 health facilities, 23 intervention facilities and 10 control facilities and 401 pregnant women across four districts. The scheme improved the availability of both functional equipment and essential drug stocks in the intervention facilities. We observed positive effects in respect to drug procurement and clinical care activities at non-intervention facilities, likely in response to improved district management performance. Birth assistants’ adherence to clinical protocols improved across all studied facilities as district health managers supervised and coached clinical staff more actively. Conclusion Despite nation-wide stock-outs and extreme health worker shortages, facilities in the study districts managed to improve maternal and neonatal health service quality by overcoming bottlenecks related to supply procurement, equipment maintenance and clinical performance. To strengthen and reform health management structures, performance-based financing may be a promising approach to sustainable improvements in quality of health care. PMID:28670014
Locations and attributes of wind turbines in Colorado, 2009
Carr, Natasha B.; Diffendorfer, Jay E.; Fancher, Tammy S.; Latysh, Natalie E.; Leib, Kenneth J.; Matherne, Anne-Marie; Turner, Christine
2011-01-01
The Colorado wind-turbine data series provides geospatial data for all wind turbines established within the State as of August 2009. Attributes specific to each turbine include: turbine location, manufacturer and model, rotor diameter, hub height, rotor height, potential megawatt output, land ownership, and county. Wind energy facility data for each turbine include: facility name, facility power capacity, number of turbines associated with each facility to date, facility developer, facility ownership, year the facility went online, and development status of wind facility. Turbine locations were derived from August 2009 1-meter true-color aerial photographs produced by the National Agriculture Imagery Program; the photographs have a positional accuracy of about + or - 5 meters. The location of turbines under construction during August 2009 likely will be less accurate than the location of existing turbines. This data series contributes to an Online Interactive Energy Atlas currently (2011) in development by the U.S. Geological Survey. The Energy Atlas will synthesize data on existing and potential energy development in Colorado and New Mexico and will include additional natural resource data layers. This information may be used by decisionmakers to evaluate and compare the potential benefits and tradeoffs associated with different energy development strategies or scenarios. Interactive maps, downloadable data layers, comprehensive metadata, and decision-support tools will be included in the Energy Atlas. The format of the Energy Atlas will facilitate the integration of information about energy with key terrestrial and aquatic resources for evaluating resource values and minimizing risks from energy development.
Locations and attributes of wind turbines in New Mexico, 2009
Carr, Natasha B.; Diffendorfer, Jay E.; Fancher, Tammy S.; Latysh, Natalie E.; Leib, Kenneth J.; Matherne, Anne-Marie; Turner, Christine
2011-01-01
The New Mexico wind-turbine data series provides geospatial data for all wind turbines established within the State as of August 2009. Attributes specific to each turbine include: turbine location, manufacturer and model, rotor diameter, hub height, rotor height, potential megawatt output, land ownership, and county. Wind energy facility data for each turbine include: facility name, facility power capacity, number of turbines associated with each facility to date, facility developer, facility ownership, year the facility went online, and development status of wind facility. Turbine locations were derived from 1-meter August 2009 true-color aerial photographs produced by the National Agriculture Imagery Program; the photographs have a positional accuracy of about + or - 5 meters. The location of turbines under construction during August 2009 likely will be less accurate than the location of existing turbines. This data series contributes to an Online Interactive Energy Atlas currently (2011) in development by the U.S. Geological Survey. The Energy Atlas will synthesize data on existing and potential energy development in Colorado and New Mexico and will include additional natural resource data layers. This information may be used by decisionmakers to evaluate and compare the potential benefits and tradeoffs associated with different energy development strategies or scenarios. Interactive maps, downloadable data layers, comprehensive metadata, and decision-support tools will be included in the Energy Atlas. The format of the Energy Atlas will facilitate the integration of information about energy with key terrestrial and aquatic resources for evaluating resource values and minimizing risks from energy development.
NASA Astrophysics Data System (ADS)
Veenendaal, Ian T.; Naylor, David A.; Gom, Brad G.
2014-08-01
The Japanese SPace Infrared telescope for Cosmology and Astrophysics (SPICA), a 3 m class telescope cooled to ~ 6 K, will provide extremely low thermal background far-infrared observations. An imaging Fourier transform spectrometer (SAFARI) is being developed to exploit the low background provided by SPICA. Evaluating the performance of the interferometer translation stage and key optical components requires a cryogenic test facility. In this paper we discuss the design challenges of a pulse tube cooled cryogenic test facility that is under development for this purpose. We present the design of the cryostat and preliminary results from component characterization and external optical metrology.
Correlates of quality educational programs.
Chester, Deborah R; Tracy, Jessamyn A; Earp, Emily; Chauhan, Reetu
2002-06-01
Preliminary evaluation findings are presented that explore relationships between educational program quality and program characteristics such as program type, security level, aftercare, teacher certification, facility size, and private versus public provider. Several program characteristics are found to be related to measurements of educational program quality. Among the major quality characteristics are proportion of program teachers that are professionally certified, smaller sized facilities versus larger facilities, level of aftercare services, and provider sources, with private for-profit providers being the lowest performing and public providers being the highest performing. The article closes with description of the Juvenile Justice Educational Enhancement Program's continuing evaluation of correlates to educational program quality through the continued development of a comprehensive database.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cho, S; Shin, E H; Kim, J
2015-06-15
Purpose: To evaluate the shielding wall design to protect patients, staff and member of the general public for secondary neutron using a simply analytic solution, multi-Monte Carlo code MCNPX, ANISN and FLUKA. Methods: An analytical and multi-Monte Carlo method were calculated for proton facility (Sumitomo Heavy Industry Ltd.) at Samsung Medical Center in Korea. The NCRP-144 analytical evaluation methods, which produced conservative estimates on the dose equivalent values for the shielding, were used for analytical evaluations. Then, the radiation transport was simulated with the multi-Monte Carlo code. The neutron dose at evaluation point is got by the value using themore » production of the simulation value and the neutron dose coefficient introduced in ICRP-74. Results: The evaluation points of accelerator control room and control room entrance are mainly influenced by the point of the proton beam loss. So the neutron dose equivalent of accelerator control room for evaluation point is 0.651, 1.530, 0.912, 0.943 mSv/yr and the entrance of cyclotron room is 0.465, 0.790, 0.522, 0.453 mSv/yr with calculation by the method of NCRP-144 formalism, ANISN, FLUKA and MCNP, respectively. The most of Result of MCNPX and FLUKA using the complicated geometry showed smaller values than Result of ANISN. Conclusion: The neutron shielding for a proton therapy facility has been evaluated by the analytic model and multi-Monte Carlo methods. We confirmed that the setting of shielding was located in well accessible area to people when the proton facility is operated.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sari Izumo; Hideo Usui; Mitsuo Tachibana
Evaluation models for determining the manpower needs for dismantling various types of equipment in uranium refining and conversion plant (URCP) have been developed. The models are widely applicable to other uranium handling facilities. Additionally, a simplified model was developed for easily and accurately calculating the manpower needs for dismantling dry conversion process-related equipment (DP equipment). It is important to evaluate beforehand project management data such as manpower needs to prepare an optimized decommissioning plan and implement effective dismantling activity. The Japan Atomic Energy Agency (JAEA) has developed the project management data evaluation system for dismantling activities (PRODIA code), which canmore » generate project management data using evaluation models. For preparing an optimized decommissioning plan, these evaluation models should be established based on the type of nuclear facility and actual dismantling data. In URCP, the dry conversion process of reprocessed uranium and others was operated until 1999, and the equipment related to the main process was dismantled from 2008 to 2011. Actual data such as manpower for dismantling were collected during the dismantling activities, and evaluation models were developed using the collected actual data on the basis of equipment classification considering the characteristics of uranium handling facility. (authors)« less
Nutritional Assessment of the Ft. Riley Non-Commissioned Officer Academy Dining Facility
1987-05-01
Initiatives, Revised Armed Forces Recipe Service, Cholesterol Consumption, Sodium, Fat Reduction, Visual Portion Estimation. Garrison Dining Facility...moderate cholesterol intakes vii i Ue should be evaluated. Revised Armed Forces Recipe Service recipes with reduced salt content should be tested and...preparation methods used and recipes followed in the NCO Academy Dining Facility. Standard recipes from the Armed Forces Recipe Service Tri-Service
Code of Federal Regulations, 2010 CFR
2010-07-01
...(s) for the type of oil handled, stored, or transported at the facility (non-persistent (Group I) or... oil handled, stored, or transported at the facility (non-persistent (Group I) or persistent (Groups II... Factors for Petroleum Oil Groups Non-Persistent Oil: Group I 1.0 Persistent Oil: Group II 1.8 Group III 2...
Code of Federal Regulations, 2013 CFR
2013-07-01
...(s) for the type of oil handled, stored, or transported at the facility (non-persistent (Group I) or... oil handled, stored, or transported at the facility (non-persistent (Group I) or persistent (Groups II... Factors for Petroleum Oil Groups Non-Persistent Oil: Group I 1.0 Persistent Oil: Group II 1.8 Group III 2...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 2, 3, 4, 5) or non-persistent (Group 1)]; and the facility's specific operating area. See sections 1... facility [persistent (Groups 2, 3, or 4) or non-persistent (Group 1)]; and the geographic area(s) in which... non-petroleum oil, fat, or grease of animal, fish, or marine mammal origin. Animal fats are further...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 2, 3, 4, 5) or non-persistent (Group 1)]; and the facility's specific operating area. See sections 1... facility [persistent (Groups 2, 3, or 4) or non-persistent (Group 1)]; and the geographic area(s) in which... non-petroleum oil, fat, or grease of animal, fish, or marine mammal origin. Animal fats are further...
Code of Federal Regulations, 2011 CFR
2011-07-01
...(s) for the type of oil handled, stored, or transported at the facility (non-persistent (Group I) or... oil handled, stored, or transported at the facility (non-persistent (Group I) or persistent (Groups II... Factors for Petroleum Oil Groups Non-Persistent Oil: Group I 1.0 Persistent Oil: Group II 1.8 Group III 2...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 2, 3, 4, 5) or non-persistent (Group 1)]; and the facility's specific operating area. See sections 1... facility [persistent (Groups 2, 3, or 4) or non-persistent (Group 1)]; and the geographic area(s) in which... non-petroleum oil, fat, or grease of animal, fish, or marine mammal origin. Animal fats are further...
NASA Johnson Space Center: White Sands Test Facility
NASA Technical Reports Server (NTRS)
Aggarwal, Pravin; Kowalski, Robert R.
2011-01-01
This slide presentation reviews the testing facilities and laboratories available at the White Sands Test Facility (WSTF). The mission of WSTF is to provide the expertise and infrastructure to test and evaluate spacecraft materials, components and propulsion systems that enable the safe exploration and use of space. There are nine rocket test stands in two major test areas, six altitude test stands, three ambient test stands,
Service Wear Test Evaluation of Structural/Proximity Firefighters Gloves
1991-06-05
CLOTHING AND TEXTILE RESEARCH FACILITY NATICK, MASSACHUSETTS Approved for public release; Technical Report No. NCTRF 188 distribution unlimited. 92 12 ;e3...ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER NAVY CLOTHING AND TEXTILE RESEARCH FACILITY P.O. BOX 59 NCTRF REPORT NO...CODE APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED 13. ABSTRACT (Maximum 200 words) The Navy Clothing and Textile Research Facility (NCTRF
ERIC Educational Resources Information Center
New York City Board of Education, Brooklyn, NY. Office of Research, Evaluation, and Assessment.
This report describes and evaluates high school programs funded under Chapter 1, Part B, of the Education Consolidation and Improvement Act (ECIA) and administered by the Institutionalized Facilities Program of the New York City Public Schools in 1989-90. The program is designed to address the educational needs of students in facilities for…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arjomandi, M; Seward, J P; Gotway, M B
2010-01-11
To study the prevalence of beryllium sensitization (BeS) and chronic beryllium disease (CBD) in a cohort of workers from a nuclear weapons research and development facility. We evaluated 50 workers with BeS with medical and occupational histories, physical examination, chest imaging with HRCT (N=49), and pulmonary function testing. Forty of these workers also underwent bronchoscopy for bronchoalveolar lavage (BAL) and transbronchial biopsies. The mean duration of employment at the facility was 18 yrs and the mean latency (from first possible exposure) to time of evaluation was 32 yrs. Five of the workers had CBD at the time of evaluation (basedmore » on histology or HRCT); three others had evidence of probable CBD. These workers with BeS, characterized by a long duration of potential Be exposure and a long latency, had a low prevalence of CBD.« less
Arjomandi, Mehrdad; Seward, James; Gotway, Michael B.; Nishimura, Stephen; Fulton, George P.; Thundiyil, Josef; King, Talmadge E.; Harber, Philip; Balmes, John R.
2012-01-01
Objective To study the prevalence of beryllium sensitization (BeS) and chronic beryllium disease (CBD) in a cohort of workers from a nuclear weapons research and development facility. Methods We evaluated 50 workers with BeS with medical and occupational histories, physical examination, chest imaging with high-resolution computed tomography (N = 49), and pulmonary function testing. Forty of these workers also underwent bronchoscopy for bronchoalveolar lavage and transbronchial biopsies. Results The mean duration of employment at the facility was 18 years and the mean latency (from first possible exposure) to time of evaluation was 32 years. Five of the workers had CBD at the time of evaluation (based on histology or high-resolution computed tomography); three others had evidence of probable CBD. Conclusions These workers with BeS, characterized by a long duration of potential Be exposure and a long latency, had a low prevalence of CBD. PMID:20523233
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boe, Stephen J.; Ogburn, Parker N.
2003-03-01
This is the second annual report of a multi-year project to operate adult collection and juvenile acclimation facilities on Catherine Creek and the upper Grande Ronde River for Snake River spring chinook salmon. These two streams have historically supported populations that provided significant tribal and non-tribal fisheries. Supplementation using conventional and captive broodstock techniques is being used to restore fisheries in these streams. Statement of Work Objectives for 2001: (1) Participate in implementation of the comprehensive multiyear operations plan for the Grande Ronde Endemic Spring chinook Supplementation Program (GRESCP). (2) Plan detailed GRESCP Monitoring and Evaluation for future years. (3)more » Ensure proper construction and trial operation of semi-permanent adult and juvenile facilities for use in 2001. (4) Plan for data collection needs for bull trout. (5) Ensure proper construction and trial operation of semi-permanent adult and juvenile facilities for use in 2001. (6) Collect summer steelhead. (7) Monitor adult endemic spring chinook salmon populations and collect broodstock. (8) Acclimate juvenile spring chinook salmon prior to release into the upper Grande Ronde River and Catherine Creek. (9) Monitor adult population abundance and characteristics of Grande Ronde River spring chinook salmon populations. (10) Monitor condition, movement, and mortality of spring chinook salmon acclimated at remote facilities. (11) Participate in Monitoring & Evaluation of the captive brood component of the Program to document contribution to the Program. (12) Monitor water quality at facilities. (13) Document accomplishments and needs to permitters, comanagers, and funding agencies. (14) Communicate Project results to the scientific community.« less
DOE LeRC photovoltaic systems test facility
NASA Technical Reports Server (NTRS)
Cull, R. C.; Forestieri, A. F.
1978-01-01
The facility was designed and built and is being operated as a national facility to serve the needs of the entire DOE National Photovoltaic Program. The object of the facility is to provide a place where photovoltaic systems may be assembled and electrically configured, without specific physical configuration, for operation and testing to evaluate their performance and characteristics. The facility as a breadboard system allows investigation of operational characteristics and checkout of components, subsystems and systems before they are mounted in field experiments or demonstrations. The facility as currently configured consist of 10 kW of solar arrays built from modules, two inverter test stations, a battery storage system, interface with local load and the utility grid, and instrumentation and control necessary to make a flexible operating facility. Expansion to 30 kW is planned for 1978. Test results and operating experience are summaried to show the variety of work that can be done with this facility.
Safety Evaluation Report for the Claiborne Enrichment Center, Homer, Louisiana (Docket No. 70-3070)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-01-01
This report documents the US Nuclear Regulatory Commission (NRC) staff review and safety evaluation of the Louisiana Energy Services, L.P. (LES, the applicant) application for a license to possess and use byproduct, source, and special nuclear material and to enrich natural uranium to a maximum of 5 percent U-235 by the gas centrifuge process. The plant, to be known as the Claiborne Enrichment Center (CEC), would be constructed near the town of Homer in Claiborne Parish, Louisiana. At full production in a given year, the plant will receive approximately 4,700 tonnes of feed UF{sub 6} and produce 870 tonnes ofmore » low-enriched UF{sub 6}, and 3,830 tonnes of depleted UF{sub 6} tails. Facility construction, operation, and decommissioning are expected to last 5, 30, and 7 years, respectively. The objective of the review is to evaluate the potential adverse impacts of operation of the facility on worker and public health and safety under both normal operating and accident conditions. The review also considers the management organization, administrative programs, and financial qualifications provided to assure safe design and operation of the facility. The NRC staff concludes that the applicant`s descriptions, specifications, and analyses provide an adequate basis for safety review of facility operations and that construction and operation of the facility does not pose an undue risk to public health and safety.« less
Low Earth orbital atomic oxygen environmental simulation facility for space materials evaluation
NASA Technical Reports Server (NTRS)
Stidham, Curtis R.; Banks, Bruce A.; Stueber, Thomas J.; Dever, Joyce A.; Rutledge, Sharon K.; Bruckner, Eric J.
1993-01-01
Simulation of low Earth orbit atomic oxygen for accelerated exposure in ground-based facilities is necessary for the durability evaluation of space power system component materials for Space Station Freedom (SSF) and future missions. A facility developed at the National Aeronautics and Space Administrations's (NASA) Lewis Research Center provides accelerated rates of exposure to a directed or scattered oxygen beam, vacuum ultraviolet (VUV) radiation, and offers in-situ optical characterization. The facility utilizes an electron-cyclotron resonance (ECR) plasma source to generate a low energy oxygen beam. Total hemispherical spectral reflectance of samples can be measured in situ over the wavelength range of 250 to 2500 nm. Deuterium lamps provide VUV radiation intensity levels in the 115 to 200 nm range of three to five equivalent suns. Retarding potential analyses show distributed ion energies below 30 electron volts (eV) for the operating conditions most suited for high flux, low energy testing. Peak ion energies are below the sputter threshold energy (approximately 30 eV) of the protective coatings on polymers that are evaluated in the facility, thus allowing long duration exposure without sputter erosion. Neutral species are expected to be at thermal energies of approximately .04 eV to .1 eV. The maximum effective flux level based on polyimide Kapton mass loss is 4.4 x 10 exp 6 atoms/((sq. cm)*s), thus providing a highly accelerated testing capability.
OMEGA: A NEW COLD X-RAY SIMULATION FACILITY FOR THE EVALUATION OF OPTICAL COATINGS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fisher, J H; Newlander, C D; Fournier, K B
We report on recent progress for the development of a new cold X-ray optical test capability using the Omega Facility located at the Laboratory for Laser Energetics (LLE) at the University of Rochester. These tests were done on the 30 kJ OMEGA laser at the Laboratory for Laser Energetics (LLE) at the University of Rochester, Rochester, NY. We conducted a six-shot series called OMEGA II on 14 July 2006 in one eight-hour day (supported by the Defense Threat Reduction Agency). The initial testing was performed using simple protected gold optical coatings on fused silica substrates. PUFFTFT analyses were completed andmore » the specimen's thermal lateral stress and transverse stress conditions were calculated and interpreted. No major anomalies were detected. Comparison of the pre- and posttest reflective measurements coupled with the TFCALC analyses proved invaluable in guiding the analyses and interpreting the observed damage. The Omega facility is a high quality facility for performing evaluation of optical coatings and coupons and provides experience for the development of future National Ignition Facility (NIF) testing.« less
High Energy Astronomy Observatory (HEAO)
1977-01-01
This photograph is of the High Energy Astronomy Observatory (HEAO)-2 telescope being evaluated by engineers in the clean room of the X-Ray Calibration Facility at the Marshall Space Flight Center (MSFC). The MSFC was heavily engaged in the technical and scientific aspects, testing and calibration, of the HEAO-2 telescope The HEAO-2 was the first imaging and largest x-ray telescope built to date. The X-Ray Calibration Facility was built in 1976 for testing MSFC's HEAO-2. The facility is the world's largest, most advanced laboratory for simulating x-ray emissions from distant celestial objects. It produced a space-like environment in which components related to x-ray telescope imaging are tested and the quality of their performance in space is predicted. The original facility contained a 1,000-foot long by 3-foot diameter vacuum tube (for the x-ray path) cornecting an x-ray generator and an instrument test chamber. Recently, the facility was upgraded to evaluate the optical elements of NASA's Hubble Space Telescope, Chandra X-Ray Observatory and Compton Gamma-Ray Observatory.
NASA Technical Reports Server (NTRS)
Kerczewski, Robert J.; Ivancic, William D.; Zuzek, John E.
1991-01-01
The development of new space communications technologies by NASA has included both commercial applications and space science requirements. NASA's Systems Integration, Test and Evaluation (SITE) Space Communication System Simulator is a hardware based laboratory simulator for evaluating space communications technologies at the component, subsystem, system, and network level, geared toward high frequency, high data rate systems. The SITE facility is well-suited for evaluation of the new technologies required for the Space Exploration Initiative (SEI) and advanced commercial systems. Described here are the technology developments and evaluation requirements for current and planned commercial and space science programs. Also examined are the capabilities of SITE, the past, present and planned future configurations of the SITE facility, and applications of SITE to evaluation of SEI technology.
Instrument Systems Analysis and Verification Facility (ISAVF) users guide
NASA Technical Reports Server (NTRS)
Davis, J. F.; Thomason, J. O.; Wolfgang, J. L.
1985-01-01
The ISAVF facility is primarily an interconnected system of computers, special purpose real time hardware, and associated generalized software systems, which will permit the Instrument System Analysts, Design Engineers and Instrument Scientists, to perform trade off studies, specification development, instrument modeling, and verification of the instrument, hardware performance. It is not the intent of the ISAVF to duplicate or replace existing special purpose facilities such as the Code 710 Optical Laboratories or the Code 750 Test and Evaluation facilities. The ISAVF will provide data acquisition and control services for these facilities, as needed, using remote computer stations attached to the main ISAVF computers via dedicated communication lines.
Analysis of LNG peakshaving-facility release-prevention systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pelto, P.J.; Baker, E.G.; Powers, T.B.
1982-05-01
The purpose of this study is to provide an analysis of release prevention systems for a reference LNG peakshaving facility. An overview assessment of the reference peakshaving facility, which preceeded this effort, identified 14 release scenarios which are typical of the potential hazards involved in the operation of LNG peakshaving facilities. These scenarios formed the basis for this more detailed study. Failure modes and effects analysis and fault tree analysis were used to estimate the expected frequency of each release scenario for the reference peakshaving facility. In addition, the effectiveness of release prevention, release detection, and release control systems weremore » evaluated.« less
Design data package and operating procedures for MSFC solar simulator test facility
NASA Technical Reports Server (NTRS)
1981-01-01
Design and operational data for the solar simulator test facility are reviewed. The primary goal of the facility is to evaluate the performance capacibility and worst case failure modes of collectors, which utilize either air or liquid transport media. The facility simulates environmental parameters such as solar radiation intensity, solar spectrum, collimation, uniformity, and solar attitude. The facility also simulates wind conditions of velocity and direction, solar system conditions imposed on the collector, collector fluid inlet temperature, and geometric factors of collector tilt and azimuth angles. Testing the simulator provides collector efficiency data, collector time constant, incident angle modifier data, and stagnation temperature values.
GUIDANCE FOR EVALUATING LANDFILL GAS EMISSIONS FROM CLOSED OR ABANDONED FACILITIES
This document provides guidance to Superfund remedial project managers, on scene coordinators, facility owners, and potentially responsible parties for conducting an air pathway analysis for landfill gas (LFG) emissions under the Comprehensive Environmental Response, Compensation...
Remediation System Evaluation, Former Honeywell Facility in Fort Washington, Pennsylvania
The Honeywell facility is located at 1100 Virginia Drive in Upper Dublin Township, Montgomery County, Pennsylvania in the Fort Washington Industrial Park. The property is approximately 67 acres and is owned by 1100 Virginia Drive Associates.
Weightless Environment Training Facility (WETF) Materials Coating Evaluation, Volume 1
NASA Technical Reports Server (NTRS)
1995-01-01
The Weightless Environment Training Facility Material Coating Evaluation project has included preparing, coating, testing, and evaluating 800 test panels of three differing substrates. Ten selected coating systems were evaluated in six separate exposure environments and subject to three tests for physical properties. Substrate materials were identified, the manner of surface preparation described, and exposure environments defined. Exposure environments included immersion exposure, cyclic exposure, and field exposure. Cyclic exposures, specifically QUV-Weatherometer and the KTA Envirotest were found to be the most agressive of the environments included in the study when all three evaluation criteria are considered. This was found to result primarily from chalking of the coatings under ultraviolet (UV) light exposure. Volumes 2 and 3 hold the 5 appendices to this report.
Identification of User Facility Related Publications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patton, Robert M; Stahl, Christopher G; Wells, Jack C
2012-01-01
Scientific user facilities provide physical resources and technical support that enable scientists to conduct experiments or simulations pertinent to their respective research. One metric for evaluating the scientific value or impact of a facility is the number of publications by users as a direct result of using that facility. Unfortunately, for a variety of reasons, capturing accurate values for this metric proves time consuming and error-prone. This work describes a new approach that leverages automated browser technology combined with text analytics to reduce the time and error involved in identifying publications related to user facilities. With this approach, scientific usermore » facilities gain more accurate measures of their impact as well as insight into policy revisions for user access.« less
Omondi Aduda, Dickens S.; Ouma, Collins; Onyango, Rosebella; Onyango, Mathews; Bertrand, Jane
2015-01-01
Background Voluntary medical male circumcision (VMMC) service delivery is complex and resource-intensive. In Kenya’s context there is still paucity of information on resource use vis-à-vis outputs as programs scale up. Knowledge of technical efficiency, productivity and potential sources of constraints is desirable to improve decision-making. Objective To evaluate technical efficiency and productivity of VMMC service delivery in Nyanza in 2011/2012 using data envelopment analysis. Design Comparative process evaluation of facilities providing VMMC in Nyanza in 2011/2012 using output orientated data envelopment analysis. Results Twenty one facilities were evaluated. Only 1 of 7 variables considered (total elapsed operation time) significantly improved from 32.8 minutes (SD 8.8) in 2011 to 30 minutes (SD 6.6) in 2012 (95%CI = 0.0350–5.2488; p = 0.047). Mean scale technical efficiency significantly improved from 91% (SD 19.8) in 2011 to 99% (SD 4.0) in 2012 particularly among outreach compared to fixed service delivery facilities (CI -31.47959–4.698508; p = 0.005). Increase in mean VRS technical efficiency from 84% (SD 25.3) in 2011 and 89% (SD 25.1) in 2012 was not statistically significant. Benchmark facilities were #119 and #125 in 2011 and #103 in 2012. Malmquist Productivity Index (MPI) at fixed facilities declined by 2.5% but gained by 4.9% at outreach ones by 2012. Total factor productivity improved by 83% (p = 0.032) in 2012, largely due to progress in technological efficiency by 79% (p = 0.008). Conclusions Significant improvement in scale technical efficiency among outreach facilities in 2012 was attributable to accelerated activities. However, ongoing pure technical inefficiency requires concerted attention. Technological progress was the key driver of service productivity growth in Nyanza. Incorporating service-quality dimensions and using stepwise-multiple criteria in performance evaluation enhances comprehensiveness and validity. These findings highlight site-level resource use and sources of variations in VMMC service productivity, which are important for program planning. PMID:25706119
[Alcohol and drug misuse of the elderly in health care facilities].
Kuhn, S; Haasen, C
2012-05-01
A nationwide representative survey was conducted in residential care facilities and facilities offering care for the elderly in their homes (home care facilities) with the aim to estimate the rate of alcohol and drug misuse among this population and to evaluate the way in which nursing staff deal with the problem. A total of 5000 randomly selected facilities were contacted with a 2-page questionnaire. Reliable data were obtained from 550 residential care facilities and from 436 home care facilities. According to the investigated facilities, the mean rate of misuse among the elderly was 14%. Nearly all facilities acknowledge the necessity to react to these facts, but only a quarter of them considered their staff to be sufficiently trained. 38.4% of the residential care facilities and 26.9% of the home care facilities have a concept on how to react to misuse problems. Addiction services are rarely contacted. The prevalence of alcohol and drug misuse among the elderly in health care facilities is high compared to the same age cohort of the total population. The lack of networking between facilities for the elderly and addiction services is remarkable. © Georg Thieme Verlag KG Stuttgart · New York.
Shielding and Activation Analyses for BTF Facility at SNS
NASA Astrophysics Data System (ADS)
Popova, Irina; Gallmeier, Franz X.
2017-09-01
The beam test facility (BTF), which simulates front end of the Spallation Neutron Source (SNS), has been built at the SNS, and is preparing for commissioning. The BTF has been assembled and will operate in one of service buildings at the site. The 2.5 MeV proton beam, produced in the facility, will be stopped in the beam dump. In order to support BTF project from radiation protection site, neutronics simulations and activation analyses were performed to evaluate the necessary shielding around the facility and radionuclide inventory of the beam stop.
The Hydrologic Instrumentation Facility of the U.S. Geological Survey
Wagner, C.R.; Jeffers, Sharon
1984-01-01
The U.S. Geological Survey Water Resources Division has improved support to the agencies field offices by the consolidation of all instrumentation support services in a single facility. This facility known as the Hydrologic Instrumentation Facility (HIF) is located at the National Space Technology Laboratory, Mississippi, about 50 miles east of New Orleans, Louisiana. The HIF is responsible for design and development, testing, evaluation, procurement, warehousing, distribution and repair of a variety of specialized hydrologic instrumentation. The centralization has resulted in more efficient and effective support of the Survey 's hydrologic programs. (USGS)
Li, Yushi; Buechel, Annie
2007-01-01
The evaluations on institutionalized care facilities from family members, after their loved ones moved into such services, are very different from culture to culture, family to family and person to person. According to a recent survey in the United States and China, it is found that different cultures and the different health conditions of the residents strongly influence family member's viewpoints on institutionalized care services. It is also found that the availability of the institutionalized care facilities plays a significant role, which strongly affects family members' evaluations on nursing home services.
Weisenthal, Karrin; Karthik, Priyadarshini; Shaw, Melissa; Sengupta, Debapriya; Bhargavan-Chatfield, Mythreyi; Burleson, Judy; Mustafa, Adel; Kalra, Mannudeep; Moore, Christopher
2018-02-01
Purpose To determine if the use of reduced-dose computed tomography (CT) for evaluation of kidney stones increased in 2015-2016 compared with that in 2011-2012, to determine variability in radiation exposure according to facility for this indication, and to establish a current average radiation dose for CT evaluation for kidney stones by querying a national dose registry. Materials and Methods This cross-sectional study was exempt from institutional review board approval. Data were obtained from the American College of Radiology dose registry for CT examinations submitted from July 2015 to June 2016. Study descriptors consistent with single-phase unenhanced CT for evaluation of kidney stones and associated RadLex® Playbook identifiers (RPIDs) were retrospectively identified. Facilities actively submitting data on kidney stone-specific CT examinations were included. Dose metrics including volumetric CT dose index, dose-length product, and size-specific dose estimate, when available, were reported, and a random effects model was run to account for clustering of CT examinations at facilities. A z-ratio was calculated to test for a significant difference between the proportion of reduced-radiation dose CT examinations (defined as those with a dose-length product of 200 mGy · cm or less) performed in 2015-2016 and the proportion performed in 2011-2012. Results Three hundred four study descriptors for kidney stone CT corresponding to data from 328 facilities that submitted 105 334 kidney stone CT examinations were identified. Reduced-dose CT examinations accounted for 8040 of 105 334 (7.6%) CT examinations, a 5.6% increase from the 1010 of 49 903 (2%) examinations in 2011-2012 (P < .001). Mean overall dose-length product was 689 mGy · cm (95% confidence interval: 667, 712), decreased from the mean of 746 mGy · cm observed in 2011-2012. Median facility dose-length product varied up to sevenfold, from less than 200 mGy · cm to greater than 1600 mGy · cm. Conclusion Use of reduced-radiation dose CT for evaluation of kidney stones has increased since 2011-2012, but remains low; variability of radiation dose according to facility continues to be wide. National mean CT radiation exposure for evaluation of renal colic during 2015-2016 decreased relative to 2011-2012 values, but remained well above what is reasonably achievable. © RSNA, 2017.
Shen, Junyi; Nakashima, Takako; Karasawa, Izumi; Furui, Tatsuro; Morishige, Kenichiro; Saijo, Tatsuyoshi
2018-05-21
Perinatal care in rural Japan is currently facing a crisis because of the lack of medical staff, especially obstetricians. In this study, a new style of postnatal care facility that combines both medical and nonmedical support is considered. Contrary to most postnatal care facilities in Japan, this new postnatal care facility accepts a puerperant from the cooperating maternity facility soon after birth (≤2 days). We conducted a hypothetical choice experiment to investigate whether this new postnatal care facility could be accepted by women in Gero City, Hida, Gifu Prefecture and how these women evaluate different kinds of postnatal care services. The results show that after a 2-day hospital stay, women from Gero City preferred to move to the new postnatal care facility over the other alternatives (continued hospitalization or discharge home). In addition, the estimated choice probabilities for selecting the postnatal care facility under different scenarios show a high level of acceptance for this new postnatal care facility. Copyright © 2018 John Wiley & Sons, Ltd.
Economic evaluation of pharmacist-led medication reviews in residential aged care facilities.
Hasan, Syed Shahzad; Thiruchelvam, Kaeshaelya; Kow, Chia Siang; Ghori, Muhammad Usman; Babar, Zaheer-Ud-Din
2017-10-01
Medication reviews is a widely accepted approach known to have a substantial impact on patients' pharmacotherapy and safety. Numerous options to optimise pharmacotherapy in older people have been reported in literature and they include medication reviews, computerised decision support systems, management teams, and educational approaches. Pharmacist-led medication reviews are increasingly being conducted, aimed at attaining patient safety and medication optimisation. Cost effectiveness is an essential aspect of a medication review evaluation. Areas covered: A systematic searching of articles that examined the cost-effectiveness of medication reviews conducted in aged care facilities was performed using the relevant databases. Pharmacist-led medication reviews confer many benefits such as attainment of biomarker targets for improved clinical outcomes, and other clinical parameters, as well as depict concrete financial advantages in terms of decrement in total medication costs and associated cost savings. Expert commentary: The cost-effectiveness of medication reviews are more consequential than ever before. A critical evaluation of pharmacist-led medication reviews in residential aged care facilities from an economical aspect is crucial in determining if the time, effort, and direct and indirect costs involved in the review rationalise the significance of conducting medication reviews for older people in aged care facilities.
NASA Technical Reports Server (NTRS)
Pirrello, C. J.; Hardin, R. D.; Heckart, M. V.; Brown, K. R.
1971-01-01
The inventory covers free jet and direct connect altitude cells, sea level static thrust stands, sea level test cells with ram air, and propulsion wind tunnels. Free jet altitude cells and propulsion wind tunnels are used for evaluation of complete inlet-engine-exhaust nozzle propulsion systems under simulated flight conditions. These facilities are similar in principal of operation and differ primarily in test section concept. The propulsion wind tunnel provides a closed test section and restrains the flow around the test specimen while the free jet is allowed to expand freely. A chamber of large diameter about the free jet is provided in which desired operating pressure levels may be maintained. Sea level test cells with ram air provide controlled, conditioned air directly to the engine face for performance evaluation at low altitude flight conditions. Direct connect altitude cells provide a means of performance evaluation at simulated conditions of Mach number and altitude with air supplied to the flight altitude conditions. Sea level static thrust stands simply provide an instrumented engine mounting for measuring thrust at zero airspeed. While all of these facilities are used for integrated engine testing, a few provide engine component test capability.
Liu, Jiannong; Li, Suying; Gilbertson, David T; Monda, Keri L; Bradbury, Brian D; Collins, Allan J
2014-10-01
Because transfusion avoidance has been the cornerstone of anemia treatment for patients with kidney disease, direct measurement of red blood cell transfusion use to assess dialysis facility anemia management performance is reasonable. We aimed to explore methods for estimating facility-level standardized transfusion ratios (STfRs) to assess provider anemia treatment practices. Retrospective cohort study. Point prevalent US hemodialysis patients on January 1, 2009, with Medicare as primary payer and dialysis duration of 90 days or longer were included (n = 223,901). All dialysis facilities with eligible patients were included (n = 5,345). Dialysis facility assignment. Receiving a red blood cell transfusion in the inpatient or outpatient setting. We evaluated 3 approaches for estimating STfR: ratio of observed to expected numbers of transfusions (STfR(obs)), a Bayesian approach (STfR(Bayes)), and a modified version of the Bayesian approach (STfR(modBayes)). The overall national transfusion rate in 2009 was 23.2 per 100 patient-years. Our model for predicting the expected number of transfusions performed well. For large facilities, all 3 STfRs worked well. However, for small facilities, while the STfR(modBayes) worked well, STfR(obs) values demonstrated instability and the STfR(Bayes) may produce more bias. Administration of transfusions to dialysis patients reflects medical practice both within and outside the dialysis unit. Some transfusions may be deemed unavoidable and transfusion practices are subject to considerable regional variation. Development of an STfR metric is feasible and reasonable for assessing anemia treatment at dialysis facilities. The STfR(obs) is simple to calculate and works well for larger dialysis facilities. The STfR(modBayes) is more analytically complex, but facilitates comparisons across all dialysis facilities, including small facilities. Copyright © 2014 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
Evaluating the Emergency Notification Systems of the NASA White Sands Test
NASA Technical Reports Server (NTRS)
Chavez, Alfred Paul
2004-01-01
The problem was that the NASA Fire and Emergency Services did not know if the current emergency notification systems on the NASA White Sands Test Facility were appropriate for alerting the employees of an emergency. The purpose of this Applied Research Project was to determine if the current emergency notification systems of the White Sands Test Facility are appropriate for alerting the employees of an emergency. This was a descriptive research project. The research questions were: 1) What are similar facilities using to alert the employees of an emergency?; 2) Are the current emergency notification systems suitable for the community hazards on the NASA White Sands Test Facility?; 3) What is the NASA Fire and Emergency Services currently using to measure the effectiveness of the emergency notification systems?; and 4) What are the current training methods used to train personnel to the emergency notification systems at the NASA White Sands Test Facility? The procedures involved were to research other established facilities, research published material from credible sources, survey the facility to determine the facility perception of the emergency notification systems, and evaluate the operating elements of the established emergency notification systems for the facility. The results were that the current systems are suitable for the type of hazards the facility may endure. The emergency notification systems are tested frequently to ensure effectiveness in the event of an emergency. Personnel are trained and participate in a yearly drill to make certain personnel are educated on the established systems. The recommendations based on the results were to operationally improve the existing systems by developing and implementing one system that can overall notify the facility of a hazard. Existing procedures and training should also be improved to ensure that all personnel are educated on what to do when the emergency notification systems are activated.
Surrogate Plant Data Base : Volume 2. Appendix C : Facilities Planning Baseline Data
DOT National Transportation Integrated Search
1983-05-01
This four volume report consists of a data base describing "surrogate" automobile and truck manufacturing plants developed as part of a methodology for evaluating capital investment requirements in new manufacturing facilities to build new fleets of ...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-12
...: Medina Facility. Location: San Antonio, Texas. Job Titles and/or Job Duties: Workers potentially exposed... Compensation Analysis and Support, National Institute for Occupational Safety and Health, 4676 Columbia Parkway...
77 FR 54570 - Senior Executive Service Performance Review Board
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-05
... DEFENSE NUCLEAR FACILITIES SAFETY BOARD Senior Executive Service Performance Review Board AGENCY... the Defense Nuclear Facilities Safety Board (DNFSB) Senior Executive Service (SES) Performance Review.... The PRB shall review and evaluate the initial summary rating of the senior executive's performance...
Research notes : drainage facility asset management : more than an inventory of pipes.
DOT National Transportation Integrated Search
2007-04-01
The primary objectives for the research project were twofold: 1) To develop and implement an Oregon-specific system for inventorying and evaluating the condition of pipes, culverts, and stormwater facilities based on the FHWA Culvert Management Syste...
Interjurisdictional coordination of Katella Avenue traffic signals
DOT National Transportation Integrated Search
1978-05-01
An overview of the Maine Facility - a two lane rural highway test site - is presented and an experiment conducted at the facility between August and December 1976 is summarized. The experiment was designed to test and evaluate the application of dyna...
2004-03-26
KENNEDY SPACE CENTER, FLA. -- An aerial photo of the hangar and storage facility near the KSC Shuttle Landing Facility. The hangar was used to collect and evaluate the pieces of Columbia debris before they were moved to permanent storage in the Vehicle Assembly Building.
ALTERNATE METHODS OF MANURE HANDLING
The objectives of this research project were to (a) construct an inexpensive storage facility for solid dairy cow manure, (b) evaluate its performance and the extent of pollutants in runoff from storage facilities, and (c) determine current manure handling practices in Vermont an...
METAL FINISHING FACILITY POLLUTION PREVENTION TOOL (MFFPPT)
The Metal Finishing Facility Pollution Tool (MFFPPT) is being developed to allow the metal finishing industry an easy method to evaluate potential pollution prevention options. In order to reduce the quantity of pollutants generated by a process, the sources of pollutants within ...
The ERDA/LeRC photovoltaic systems test facility
NASA Technical Reports Server (NTRS)
Forestieri, A. F.
1977-01-01
A test facility was designed, and built to provide a place where photovoltaic systems may be assembled and electrically configured, to evaluate system performance and characteristics. The facility consists of a solar cell array of an initial 10-kW peak power rating, test hardware for several alternate methods of power conditioning, a variety of loads, an electrical energy storage system, and an instrumentation and data acquisition system.
McLaren, Zoë M; Sharp, Alana R; Zhou, Jifang; Wasserman, Sean; Nanoo, Ananta
2017-02-01
To assess the performance of healthcare facilities by means of indicators based on guidelines for clinical care of TB, which is likely a good measure of overall facility quality. We assessed quality of care in all public health facilities in South Africa using graphical, correlation and locally weighted kernel regression analysis of routine TB test data. Facility performance falls short of national standards of care. Only 74% of patients with TB provided a second specimen for testing, 18% received follow-up testing and 14% received drug resistance testing. Only resistance testing rates improved over time, tripling between 2004 and 2011. National awareness campaigns and changes in clinical guidelines had only a transient impact on testing rates. The poorest performing facilities remained at the bottom of the rankings over the period of study. The optimal policy strategy requires both broad-based policies and targeted resources to poor performers. This approach to assessing facility quality of care can be adapted to other contexts and also provides a low-cost method for evaluating the effectiveness of proposed interventions. Devising targeted policies based on routine data is a cost-effective way to improve the quality of public health care provided. © 2016 John Wiley & Sons Ltd.
Evaluation of mercury in the liquid waste processing facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jain, Vijay; Shah, Hasmukh; Occhipinti, John E.
2015-08-13
This report provides a summary of Phase I activities conducted to support an Integrated Evaluation of Mercury in Liquid Waste System (LWS) Processing Facilities. Phase I activities included a review and assessment of the liquid waste inventory and chemical processing behavior of mercury using a system by system review methodology approach. Gaps in understanding mercury behavior as well as action items from the structured reviews are being tracked. 64% of the gaps and actions have been resolved.
1987-08-01
conflicts between the facility and local standards, and to evaluate the probability of conflict resulting from any planned expansions. 2-2 Visual Resources...on staffing and housing for the facility itself is contained in Table 2-7. Additional data on the socio - economic background of Ebeye, including...resources, noise, and socio - economics. As a result of that evaluation, consequences vere assigned to one of three categories: insignificant, mitigable, or
Development and implementation of a human accuracy program in patient foodservice.
Eden, S H; Wood, S M; Ptak, K M
1987-04-01
For many years, industry has utilized the concept of human error rates to monitor and minimize human errors in the production process. A consistent quality-controlled product increases consumer satisfaction and repeat purchase of product. Administrative dietitians have applied the concepts of using human error rates (the number of errors divided by the number of opportunities for error) at four hospitals, with a total bed capacity of 788, within a tertiary-care medical center. Human error rate was used to monitor and evaluate trayline employee performance and to evaluate layout and tasks of trayline stations, in addition to evaluating employees in patient service areas. Long-term employees initially opposed the error rate system with some hostility and resentment, while newer employees accepted the system. All employees now believe that the constant feedback given by supervisors enhances their self-esteem and productivity. Employee error rates are monitored daily and are used to counsel employees when necessary; they are also utilized during annual performance evaluation. Average daily error rates for a facility staffed by new employees decreased from 7% to an acceptable 3%. In a facility staffed by long-term employees, the error rate increased, reflecting improper error documentation. Patient satisfaction surveys reveal satisfaction, for tray accuracy increased from 88% to 92% in the facility staffed by long-term employees and has remained above the 90% standard in the facility staffed by new employees.
Manthalu, Gerald; Yi, Deokhee; Farrar, Shelley; Nkhoma, Dominic
2016-01-01
The Government of Malawi has signed contracts called service level agreements (SLAs) with mission health facilities in order to exempt their catchment populations from paying user fees. Government in turn reimburses the facilities for the services that they provide. SLAs started in 2006 with 28 out of 165 mission health facilities and increased to 74 in 2015. Most SLAs cover only maternal, neonatal and in some cases child health services due to limited resources. This study evaluated the effect of user fee exemption on the utilization of maternal health services. The difference-in-differences approach was combined with propensity score matching to evaluate the causal effect of user fee exemption. The gradual uptake of the policy provided a natural experiment with treated and control health facilities. A second control group, patients seeking non-maternal health care at CHAM health facilities with SLAs, was used to check the robustness of the results obtained using the primary control group. Health facility level panel data for 142 mission health facilities from 2003 to 2010 were used. User fee exemption led to a 15% (P < 0.01) increase in the mean proportion of women who made at least one antenatal care (ANC) visit during pregnancy, a 12% (P < 0.05) increase in average ANC visits and an 11% (P < 0.05) increase in the mean proportion of pregnant women who delivered at the facilities. No effects were found for the proportion of pregnant women who made the first ANC visit in the first trimester and the proportion of women who made postpartum care visits. We conclude that user fee exemption is an important policy for increasing maternal health care utilization. For certain maternal services, however, other determinants may be more important. PMID:27175033
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lindell, M.A.; Grape, S.; Haekansson, A.
The sustainability criterion for Gen IV nuclear energy systems inherently presumes the availability of efficient fuel recycling capabilities. One area for research on advanced fuel recycling concerns safeguards aspects of this type of facilities. Since a recycling facility may be considered as sensitive from a non-proliferation perspective, it is important to address these issues early in the design process, according to the principle of Safeguards By Design. Presented in this paper is a mode of procedure, where assessments of the proliferation resistance (PR) of a recycling facility for fast reactor fuel have been performed so as to identify the weakestmore » barriers to proliferation of nuclear material. Two supplementing established methodologies have been applied; TOPS (Technological Opportunities to increase Proliferation resistance of nuclear power Systems) and PR-PP (Proliferation Resistance and Physical Protection evaluation methodology). The chosen fuel recycling facility belongs to a small Gen IV lead-cooled fast reactor system that is under study in Sweden. A schematic design of the recycling facility, where actinides are separated using solvent extraction, has been examined. The PR assessment methodologies make it possible to pinpoint areas in which the facility can be improved in order to reduce the risk of diversion. The initial facility design may then be slightly modified and/or safeguards measures may be introduced to reduce the total identified proliferation risk. After each modification of design and/or safeguards implementation, a new PR assessment of the revised system can then be carried out. This way, each modification can be evaluated and new ways to further enhance the proliferation resistance can be identified. This type of iterative procedure may support Safeguards By Design in the planning of new recycling plants and other nuclear facilities. (authors)« less
Novignon, Jacob; Nonvignon, Justice
2017-06-12
Health centers in Ghana play an important role in health care delivery especially in deprived communities. They usually serve as the first line of service and meet basic health care needs. Unfortunately, these facilities are faced with inadequate resources. While health policy makers seek to increase resources committed to primary healthcare, it is important to understand the nature of inefficiencies that exist in these facilities. Therefore, the objectives of this study are threefold; (i) estimate efficiency among primary health facilities (health centers), (ii) examine the potential fiscal space from improved efficiency and (iii) investigate the efficiency disparities in public and private facilities. Data was from the 2015 Access Bottlenecks, Cost and Equity (ABCE) project conducted by the Institute for Health Metrics and Evaluation. The Stochastic Frontier Analysis (SFA) was used to estimate efficiency of health facilities. Efficiency scores were then used to compute potential savings from improved efficiency. Outpatient visits was used as output while number of personnel, hospital beds, expenditure on other capital items and administration were used as inputs. Disparities in efficiency between public and private facilities was estimated using the Nopo matching decomposition procedure. Average efficiency score across all health centers included in the sample was estimated to be 0.51. Also, average efficiency was estimated to be about 0.65 and 0.50 for private and public facilities, respectively. Significant disparities in efficiency were identified across the various administrative regions. With regards to potential fiscal space, we found that, on average, facilities could save about GH₵11,450.70 (US$7633.80) if efficiency was improved. We also found that fiscal space from efficiency gains varies across rural/urban as well as private/public facilities, if best practices are followed. The matching decomposition showed an efficiency gap of 0.29 between private and public facilities. There is need for primary health facility managers to improve productivity via effective and efficient resource use. Efforts to improve efficiency should focus on training health workers and improving facility environment alongside effective monitoring and evaluation exercises.
Evaluation of the long-term performance of six alternative disposal methods for LLRW
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kossik, R.; Sharp, G.; Chau, T.
1995-12-31
The State of New York has carried out a comparison of six alternative disposal methods for low-level radioactive waste (LLRW). An important part of these evaluations involved quantitatively analyzing the long-term (10,000 yr) performance of the methods with respect to dose to humans, radionuclide concentrations in the environment, and cumulative release from the facility. Four near-surface methods (covered above-grade vault, uncovered above-grade vault, below-grade vault, augered holes) and two mine methods (vertical shaft mine and drift mine) were evaluated. Each method was analyzed for several generic site conditions applicable for the state. The evaluations were carried out using RIP (Repositorymore » Integration Program), an integrated, total system performance assessment computer code which has been applied to radioactive waste disposal facilities both in the U.S. (Yucca Mountain, WIPP) and worldwide. The evaluations indicate that mines in intact low-permeability rock and near-surface facilities with engineered covers generally have a high potential to perform well (within regulatory limits). Uncovered above-grade vaults and mines in highly fractured crystalline rock, however, have a high potential to perform poorly, exceeding regulatory limits.« less
Reengineering of waste management at the Oak Ridge National Laboratory. Volume 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Myrick, T.E.
1997-08-01
A reengineering evaluation of the waste management program at the Oak Ridge National Laboratory (ORNL) was conducted during the months of February through July 1997. The goal of the reengineering was to identify ways in which the waste management process could be streamlined and improved to reduce costs while maintaining full compliance and customer satisfaction. A Core Team conducted preliminary evaluations and determined that eight particular aspects of the ORNL waste management program warranted focused investigations during the reengineering. The eight areas included Pollution Prevention, Waste Characterization, Waste Certification/Verification, Hazardous/Mixed Waste Stream, Generator/WM Teaming, Reporting/Records, Disposal End Points, and On-Sitemore » Treatment/Storage. The Core Team commissioned and assembled Process Teams to conduct in-depth evaluations of each of these eight areas. The Core Team then evaluated the Process Team results and consolidated the 80 process-specific recommendations into 15 overall recommendations. Benchmarking of a commercial nuclear facility, a commercial research facility, and a DOE research facility was conducted to both validate the efficacy of these findings and seek additional ideas for improvement. The outcome of this evaluation is represented by the 15 final recommendations that are described in this report.« less
Overview of environmental and hydrogeologic conditions at Moses Point, Alaska
Dorava, J.M.; Ayres, R.P.; Sisco, W.C.
1994-01-01
The Federal Aviation Administration facility at Moses Point is located at the mouth of the Kwiniuk River on the Seward Peninsula in northwestern Alaska. This area has long cold winters and short summers which affect the hydrology of the area. The Federal Aviation Administration owns or operates airport support facilities at the Moses Point site and wishes to consider the subsistence lifestyles of area residents and the quality of the current environment when evaluating options for remediation of environmental contamination at their facilities. Currently no operating wells are in the area, but the vulnerability of the aquifer and other alternative water supplies are being evaluated because the Federal Aviation Administration has a potential liability for the storage and use of hazardous materials in the area.
Papa, Jillian; Rodriguez, Gertrudes; Robinson, Deborah
2017-01-01
Introduction Obesity is a major health concern in every US age group. Approximately one in 4 children in Arizona’s Special Supplemental Nutrition Program for Women, Infants, and Children is overweight or obese. The Arizona Department of Health Services developed the Empower program to promote healthy environments in licensed child care facilities. The program consists of 10 standards, including one standard for each of these 5 areas: physical activity and screen time, breastfeeding, fruit juice and water, family-style meals, and staff training. The objective of this evaluation was to determine the level of implementation of these 5 Empower standards. Methods A self-assessment survey was completed from July 2013 through June 2015 by 1,850 facilities to evaluate the level of implementation of 5 Empower standards. We calculated the percentage of facilities that reported the degree to which they implemented each standard and identified common themes in comments recorded in the survey. Results All facilities reported either full or partial implementation of the 5 standards. Of 1,678 facilities, 21.7% (n = 364) reported full implementation of all standards, and 78.3% (n = 1,314) reported at least partial implementation. Staff training, which has only one component, had the highest level of implementation: 77.4% (n = 1,299) reported full implementation. Only 44.0% (n = 738) reported full implementation of the standard on a breastfeeding-friendly environment. Conclusion Arizona child care facilities have begun to implement the Empower program, but facilities will need more education, technical assistance, and support in some areas to fully implement the program. PMID:28880840
Papa, Jillian; Agostinelli, Joan; Rodriguez, Gertrudes; Robinson, Deborah
2017-09-07
Obesity is a major health concern in every US age group. Approximately one in 4 children in Arizona's Special Supplemental Nutrition Program for Women, Infants, and Children is overweight or obese. The Arizona Department of Health Services developed the Empower program to promote healthy environments in licensed child care facilities. The program consists of 10 standards, including one standard for each of these 5 areas: physical activity and screen time, breastfeeding, fruit juice and water, family-style meals, and staff training. The objective of this evaluation was to determine the level of implementation of these 5 Empower standards. A self-assessment survey was completed from July 2013 through June 2015 by 1,850 facilities to evaluate the level of implementation of 5 Empower standards. We calculated the percentage of facilities that reported the degree to which they implemented each standard and identified common themes in comments recorded in the survey. All facilities reported either full or partial implementation of the 5 standards. Of 1,678 facilities, 21.7% (n = 364) reported full implementation of all standards, and 78.3% (n = 1,314) reported at least partial implementation. Staff training, which has only one component, had the highest level of implementation: 77.4% (n = 1,299) reported full implementation. Only 44.0% (n = 738) reported full implementation of the standard on a breastfeeding-friendly environment. Arizona child care facilities have begun to implement the Empower program, but facilities will need more education, technical assistance, and support in some areas to fully implement the program.
Advanced parking information system evaluation report
DOT National Transportation Integrated Search
1997-01-01
This report documents the evaluation analysis and results of the operational test. The evaluation assesses the impact/effect of the advance parking information system on the motoring public, parking facility operators, roadway system operations, and ...
DOT National Transportation Integrated Search
2004-01-01
The objectives of this study were to assess the quantity and quality of salt-contaminated water generated from stormwater runoff at VDOT's salt storage facilities and to evaluate management/treatment alternatives to reduce costs and better protect th...
75 FR 56999 - Senior Executive Service Performance Review Board
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-17
... DEFENSE NUCLEAR FACILITIES SAFETY BOARD Senior Executive Service Performance Review Board AGENCY... the Defense Nuclear Facilities Safety Board (DNFSB) Senior Executive Service (SES) Performance Review... performance review boards. The PRB shall review and evaluate the initial summary rating of the senior...
Guide to metropolitan transportation planning under ISTEA : how the pieces fit together
DOT National Transportation Integrated Search
1977-01-01
An overview of the Maine Facility--a two-lane rural highway test site--is presented, and past experimentation conducted at the facility is summarized. Experiments briefly described include Speed Control in Rural School Zones, Evaluation of Speed Cont...
EVALUATION OF STYRENE EMISSIONS FROM A SHOWER STALL/BATHTUB MANUFACTURING FACILITY
The report gives results of emissions measurements carried out at a representative facility (Eljer Plumbingware in Wilson, NC) that manufactures polyester-resin-reinforced shower stalls and bathtubs by spraying styrene-based resins onto molds in vented, open, spray booths. Styren...
Planning for Capital Reinvestment.
ERIC Educational Resources Information Center
Biedenweg, Frederick; Weisburg-Swanson, Lynda; Gardner, Catherine
1998-01-01
Describes and evaluates four alternatives for planning and budgeting for capital reinvestment for college and university facilities: physical plant auditing; a depreciation-based approach; percentage of current replacement value; and facility subsystem modeling, or life-cycle modeling. Each has advantages and limitations in budgeting for and…
2006-10-01
pipe facilities). The Dashboard is based on the NetBeans application platform, a Java-based tool kit. Tools may be written in any language...manner loosely analogous to UNIX shells (especially with respect to UNIX pipe facilities). The Dashboard is based on the NetBeans application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Badwan, F.M.; Herring, K.S.
1993-08-01
Many of the buildings at the Rocky Flats Plant were designed and built before modern standards were developed, including standards for protection against extreme natural phenomenon such as tornadoes, earthquakes, and floods. The purpose of the SEP is to establish an integrated approach to assessing the design adequacy of specific high and moderate hazard Rocky Flats facilities from a safety perspective and to establish a basis for defining any needed facility improvements. The SEP is to be carried out in three Phases. In Phase 1, topics to be evaluated and an evaluation plan for each topic were developed. Any differencesmore » between Current Design Requirements (CDR) or acceptance criteria and the design of existing facilities, will be identified during Phase 2 and assessed using an integrated systematic approach during Phase 3. The integrated assessment performed during Phase 3 provides a process for evaluating the differences between existing facility design and CDRs so that decisions on corrective actions can be made on the basis of relative risk reduction and cost effectiveness. These efforts will ensure that a balanced and integrated level of safety is achieved for long-term operation of these buildings. Through appropriate selection of topics and identification of the structures, systems, and components to be evaluated, the SEP will address outstanding design issues related to the prevention and mitigation of design basis accidents, including those arising from natural phenomena. The objective of the SEP is not to bring these buildings into strict compliance with current requirements, but rather to ensure that an adequate level of safety is achieved in an economical fashion.« less
Solar Thermal Concept Evaluation
NASA Technical Reports Server (NTRS)
Hawk, Clark W.; Bonometti, Joseph A.
1995-01-01
Concentrated solar thermal energy can be utilized in a variety of high temperature applications for both terrestrial and space environments. In each application, knowledge of the collector and absorber's heat exchange interaction is required. To understand this coupled mechanism, various concentrator types and geometries, as well as, their relationship to the physical absorber mechanics were investigated. To conduct experimental tests various parts of a 5,000 watt, thermal concentrator, facility were made and evaluated. This was in anticipation at a larger NASA facility proposed for construction. Although much of the work centered on solar thermal propulsion for an upper stage (less than one pound thrust range), the information generated and the facility's capabilities are applicable to material processing, power generation and similar uses. The numerical calculations used to design the laboratory mirror and the procedure for evaluating other solar collectors are presented here. The mirror design is based on a hexagonal faceted system, which uses a spherical approximation to the parabolic surface. The work began with a few two dimensional estimates and continued with a full, three dimensional, numerical algorithm written in FORTRAN code. This was compared to a full geometry, ray trace program, BEAM 4, which optimizes the curvatures, based on purely optical considerations. Founded on numerical results, the characteristics of a faceted concentrator were construed. The numerical methodologies themselves were evaluated and categorized. As a result, the three-dimensional FORTRAN code was the method chosen to construct the mirrors, due to its overall accuracy and superior results to the ray trace program. This information is being used to fabricate and subsequently, laser map the actual mirror surfaces. Evaluation of concentrator mirrors, thermal applications and scaling the results of the 10 foot diameter mirror to a much larger concentrator, were studied. Evaluations, recommendations and pit falls regarding the structure, materials and facility design are presented.
Cretin, S; Farley, D O; Dolter, K J; Nicholas, W
2001-08-01
Implementing clinical practice guidelines to change patient outcomes presents a challenge. Studies of single interventions focused on changing provider behavior demonstrate modest effects, suggesting that effective guideline implementation requires a multifaceted approach. Traditional biomedical research designs are not well suited to evaluating systems interventions. RAND and the Army Medical Department collaborated to develop and evaluate a system for implementing guidelines and documenting their effects on patient care. The evaluation design blended quality improvement, case study, and epidemiologic methods. A formative evaluation of implementation process and an outcome evaluation of patient impact were combined. Guidelines were implemented in 3 successive demonstrations targeting low back pain, asthma, and diabetes. This paper reports on the first wave of 4 facilities implementing a low back pain guideline. Organizational climate and culture, motivation, leadership commitment, and resources were assessed. Selected indicators of processes and outcomes of care were compared before, during, and after guideline implementation at the demonstration facilities and at comparison facilities. Logistic regression analysis was used to test for guideline effects on patient care. Process evaluation documented varied approaches to quality improvement across sites. Outcome evaluation revealed a significant downward trend in the percentage of acute low back pain patients referred to physical therapy or chiropractic care (10.7% to 7.2%) at demonstration sites and no such trend at control sites. Preliminary results suggest the power of this design to stimulate improvements in guideline implementation while retaining the power to evaluate rigorously effects on patient care.
Atmospheric Reentry Materials and Structures Evaluation Facility (ARMSEF). User Test Planning Guide
NASA Technical Reports Server (NTRS)
2011-01-01
Test process, milestones and inputs are unknowns to first-time users of the ARMSEF. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.
Winning market positioning strategies for long term care facilities.
Higgins, L F; Weinstein, K; Arndt, K
1997-01-01
The decision to develop an aggressive marketing strategy for its long term care facility has become a priority for the management of a one-hundred bed facility in the Rocky Mountain West. Financial success and lasting competitiveness require that the facility in question (Deer Haven) establish itself as the preferred provider of long term care for its target market. By performing a marketing communications audit, Deer Haven evaluated its present market position and created a strategy for solidifying and dramatizing this position. After an overview of present conditions in the industry, we offer a seven step process that provides practical guidance for positioning a long term care facility. We conclude by providing an example application.
DOE Office of Scientific and Technical Information (OSTI.GOV)
LUECK, K.J.
2004-10-18
This report documents an engineering study conducted to evaluate alternatives for treating secondary waste in the secondary treatment train (STT) of the Hanford Site 200 Area Effluent Treatment Facility (ETF). The study evaluates ETF STT treatment alternatives and recommends preferred alternatives for meeting the projected future missions of the ETF. The preferred alternative(s) will process projected future ETF influents to produce a solid waste acceptable for final disposal on the Hanford Site. The main text of this report summarizes the ETF past and projected operations, lists the assumptions about projected operations that provide the basis for the engineering evaluation, andmore » summarizes the evaluation process. The evaluation process includes identification of available modifications to the current ETF process, screens those modifications for technical viability, evaluates the technically viable alternatives, and provides conclusions and recommendations based on that evaluation.« less
Argo, Joshua L; Vick, Catherine C; Graham, Laura A; Itani, Kamal M F; Bishop, Michael J; Hawn, Mary T
2009-11-01
This study evaluated elective surgical case cancellation (CC) rates, reasons for these cancellations, and identified areas for improvement within the Veterans Health Administration (VA) system. CC data for 2006 were collected from the scheduling software for 123 VA facilities. Surveys were distributed to 40 facilities (10 highest and 10 lowest CC rates for high- and low-volume facilities). CC reasons were standardized and piloted at 5 facilities. Of 329,784 cases scheduled by 9 surgical specialties, 40,988 (12.4%) were cancelled. CC reasons (9,528) were placed into 6 broad categories: patient (35%), work-up/medical condition change (28%), facility (20%), surgeon (8%), anesthesia (1%), and miscellaneous (8%). Survey results show areas for improvement at the facility level and a standardized list of 28 CC reasons was comprehensive. Interventions that decrease cancellations caused by patient factors, inadequate work-up, and facility factors are needed to reduce overall elective surgical case cancellations.
A space debris simulation facility for spacecraft materials evaluation
NASA Technical Reports Server (NTRS)
Taylor, Roy A.
1987-01-01
A facility to simulate the effects of space debris striking an orbiting spacecraft is described. This facility was purchased in 1965 to be used as a micrometeoroid simulation facility. Conversion to a Space Debris Simulation Facility began in July 1984 and it was placed in operation in February 1985. The facility consists of a light gas gun with a 12.7-mm launch tube capable of launching 2.5-12.7 mm projectiles with a mass of 4-300 mg and velocities of 2-8 km/sec, and three target tanks of 0.067 m, 0.53 a m and 28.5 a m. Projectile velocity measurements are accomplished via pulsed X-ray, laser diode detectors, and a Hall photographic station. This facility is being used to test development structural configurations and candidate materials for long duration orbital spacecraft. A summary of test results are also described.
1991-09-01
System ( CAPMS ) in lieu of using DODI 4151.15H. Facility utilization rate computation is not explicitly defined; it is merely identified as a ratio of...front of a bottleneck buffers the critical resource and protects against disruption of the system. This approach optimizes facility utilization by...run titled BUFFERED BASELINE. Three different levels of inventory were used to evaluate the effect of increasing the inventory level on critical
Qualitative evaluation of Rhode Island’s healthcare worker influenza vaccination regulations
Lindley, Megan C.; Dube, Donna; Kalayil, Elizabeth J.; Kim, Hanna; Paiva, Kristi; Raymond, Patricia
2015-01-01
Objective To evaluate Rhode Island’s revised vaccination regulations requiring healthcare workers (HCWs) to receive annual influenza vaccination or wear a mask during patient care when influenza is widespread. Design Semi-structured telephone interviews conducted in a random sample of healthcare facilities. Setting Rhode Island healthcare facilities covered by the HCW regulations, including hospitals, nursing homes, community health centers, nursing service agencies, and home nursing care providers. Participants Staff responsible for collecting and/or reporting facility-level HCW influenza vaccination data to comply with Rhode Island HCW regulations. Methods Interviews were transcribed and individually coded by interviewers to identify themes; consensus on coding differences was reached through discussion. Common themes and illustrative quotes are presented. Results Many facilities perceived the revised regulations as extending their existing influenza vaccination policies and practices. Despite variations in implementation, nearly all facilities implemented policies that complied with the minimum requirements of the regulations. The primary barrier to implementing the HCW regulations was enforcement of masking among unvaccinated HCWs, which required timely tracking of vaccination status and additional time and effort by supervisors. Factors facilitating implementation included early and regular communication from the state health department and facilities’ ability to adapt existing influenza vaccination programs to incorporate provisions of the revised regulations. Conclusions Overall, facilities successfully implemented the revised HCW regulations during the 2012–2013 influenza season. Continued maintenance of the regulations is likely to reduce transmission of influenza and resulting morbidity and mortality in Rhode Island’s healthcare facilities. PMID:25192807
Evaluation of Mercury in Liquid Waste Processing Facilities - Phase I Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jain, V.; Occhipinti, J.; Shah, H.
2015-07-01
This report provides a summary of Phase I activities conducted to support an Integrated Evaluation of Mercury in Liquid Waste System (LWS) Processing Facilities. Phase I activities included a review and assessment of the liquid waste inventory and chemical processing behavior of mercury using a system by system review methodology approach. Gaps in understanding mercury behavior as well as action items from the structured reviews are being tracked. 64% of the gaps and actions have been resolved.
Evaluation of mercury in liquid waste processing facilities - Phase I report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jain, V.; Occhipinti, J. E.; Shah, H.
2015-07-01
This report provides a summary of Phase I activities conducted to support an Integrated Evaluation of Mercury in Liquid Waste System (LWS) Processing Facilities. Phase I activities included a review and assessment of the liquid waste inventory and chemical processing behavior of mercury using a system by system review methodology approach. Gaps in understanding mercury behavior as well as action items from the structured reviews are being tracked. 64% of the gaps and actions have been resolved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1991-09-01
This report presents compiled information concerning a facility investigation of waste area group 6(WAG-6), of the solid waste management units (SWMU's) at Oak Ridge National Laboratory (ORNL). The WAG is a shallow ground disposal area for low-level radioactive wastes and chemical wastes. The report contains information on hydrogeological data, contaminant characterization, radionuclide concentrations, risk assessment and baseline human health evaluation including a toxicity assessment, and a baseline environmental evaluation.
Biological treatment of hazardous aqueous wastes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Opatken, E.J.; Howard, H.K.; Bond, J.J.
1987-06-01
Studies were conducted with a rotating biological conractor (RBC) to evaluate the treatability of leachates from the Stringfellow and New Lyme hazardous-waste sites. The leachates were transported from the waste sites to Cincinnati at the United States Environmental Protection Agency's Testing and Evaluation Facility. A series of batches were run with primary effluent from Cincinnati's Mill Creek Sewage Treatment Facility. The paper reports on the results from these experiments and the effectiveness of an RBC to adequately treat leachates from Superfund sites.
NASA Astrophysics Data System (ADS)
Martel, C. J.; Phetteplace, G. E.
1982-05-01
This report presents a five-step procedure for evaluating the technical and economic feasibility of using heat pumps to recover heat from treatment plant effluent. The procedure is meant to be used at the facility planning level by engineers who are unfamiliar with this technology. An example of the use of the procedure and general design information are provided. Also, the report reviews the operational experience with heat pumps at wastewater plants located in Fairbanks, Alaska, Madison, Wisconsin, and Wilton, Maine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-08-01
The Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee, is operated for the U.S. Department of Energy (DOE) by Lockheed Martin Energy System (Energy Systems). ORNL has pioneered waste disposal technologies since World War II as part of its DOE mission. In the late 1950s, at the request of the National Academy of Sciences, efforts were made to develop a permanent disposal alternative to the surface and tanks at ORNL. One such technology, the hydrofracture process, involved inducing fractures in a geologic host formation (a low-permeability shale) at depths of up to 1100 ft and injecting a radioactive groutmore » slurry containing low-level liquid or tank sludge waste, cement, and other additives at an injection pressure of 2000 to 8500 psi. The objective of the effort was to develop a grout dig could be injected as a slurry and would solidify after injection, thereby entombing the radioisotopes contained in the low-level liquid or tank sludge waste. Four sites at ORNL were used: two experimental (HF-1 and HF-2); one developmental, later converted to batch process [Old Hydrofracture Facility (BF-3)]; and one production facility [New Hydrofracture Facility (BF-4)]. This document provides the environmental, restoration program with information about the the results of an evaluation of WAG 10 wells associated with the New Hydrofracture Facility at ORNL.« less
Tushi, Aonungdok; Kaur, Prabhdeep
2017-01-01
Public sector health facilities were poorly managed due to a history of conflict in Nagaland, India. Government of Nagaland introduced "Nagaland Communitisation of Public Institutions and Services Act" in 2002. Main objectives of the evaluation were to review the functioning of Health Center Managing Committees (HCMCs), deliver health services in the institutions managed by HCMC, identify strengths as well as challenges perceived by HCMC members in the rural areas of Mokokchung district, Nagaland. The evaluation was made using input, process and output indicators. A doctor, the HCMC Chairman and one member from each of the three community health centers (CHC) and four primary health centers (PHC) were surveyed using a semi-structured questionnaire and an in-depth interview guide. Proportions for quantitative data were computed and key themes from the same were identified. Overall; the infrastructure, equipment and outpatient/inpatient service availability was satisfactory. There was a lack of funds and shortage of doctors, drugs as well as laboratory facilities. HCMCs were in place and carried out administrative activities. HCMCs felt ownership, mobilized community contributions and managed human resources. HCMC members had inadequate funds for their transport and training. They faced challenges in service delivery due to political interference and lack of adequate human, material, financial resources. Communitisation program was operational in the district. HCMC members felt the ownership of health facilities. Administrative, political support and adequate funds from the government are needed for effective functioning of HCMCs and optimal service delivery in public sector facilities.
2005-01-01
Abstract The purpose of this study was to evaluate the ability of a commercial air-filtration system to reduce aerosol transmission of Porcine reproductive and respiratory syndrome virus (PRRSV). The system consisted of a pre-filter and 2 filters with EU8 and EU13 ratings. In each of 4 trials, 5 PRRSV-infected donor pigs and 1 naïve recipient pig (each 25 kg) were housed in opposing chambers connected by a 1.3-m-long duct. The system filtered air entering 1 recipient-pig chamber (filtered facility) from the donor- chamber but not a 2nd recipient-pig chamber (nonfiltered facility). The donor pigs had been experimentally infected with PRRSV MN-184, an isolate previously documented to be shed at a high frequency in contagious aerosols. On days 3 to 7 after infection of the donors, the 2 groups were housed in their respective chambers for 6 h and then in separate facilities, where samples were collected for testing by polymerase chain reaction and enzyme-linked immunosorbent assay over 14 d. Aerosol transmission was observed in 6 of the 20 replicates in the nonfiltered facility, whereas all pigs remained PRRSV-negative in the filtered facility; the difference was significant at P < 0.01. Thus, under the conditions of this study, the air-filtration system evaluated appeared to be highly effective at reducing aerosol transmission of PRRSV. PMID:16479728
DOT National Transportation Integrated Search
2012-06-01
The following document is the final report for ALDOT Project 930655 which summarizes the design and : construction of the Auburn University Erosion and Sediment Control Testing Facility (AUESCTF) along : with several intermediatescale, f...
10 CFR 50.34 - Contents of applications; technical information.
Code of Federal Regulations, 2014 CFR
2014-01-01
... capability for containment purging/venting designed to minimize the purging time consistent with ALARA... similarities to and differences from, facilities of similar design for which applications have previously been... to features affecting facility design. Special attention should be directed to the site evaluation...
10 CFR 50.34 - Contents of applications; technical information.
Code of Federal Regulations, 2012 CFR
2012-01-01
... capability for containment purging/venting designed to minimize the purging time consistent with ALARA... similarities to and differences from, facilities of similar design for which applications have previously been... to features affecting facility design. Special attention should be directed to the site evaluation...
LCDRS FLOW FROM DOUBLE-LINED LANDFILLS AND SURFACE IMPOUNDMENTS
This report presents field data on the measured flows of liquid from the leakage detection, collection, and removal systems (LDCRSs) of 28 double-lined surface impoundment facilities. or each facility, information on design and operation is presented, as is an evaluation of the s...
10 CFR 216.4 - Evaluation by DOE of applications.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Energy DEPARTMENT OF ENERGY OIL MATERIALS ALLOCATION AND PRIORITY PERFORMANCE UNDER CONTRACTS OR ORDERS... described supplies of materials and equipment, services, or facilities are critical and essential to the... and equipment, services, or facilities described in the application are critical and essential to an...
10 CFR 216.4 - Evaluation by DOE of applications.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Energy DEPARTMENT OF ENERGY OIL MATERIALS ALLOCATION AND PRIORITY PERFORMANCE UNDER CONTRACTS OR ORDERS... described supplies of materials and equipment, services, or facilities are critical and essential to the... and equipment, services, or facilities described in the application are critical and essential to an...
10 CFR 216.4 - Evaluation by DOE of applications.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Energy DEPARTMENT OF ENERGY OIL MATERIALS ALLOCATION AND PRIORITY PERFORMANCE UNDER CONTRACTS OR ORDERS... described supplies of materials and equipment, services, or facilities are critical and essential to the... and equipment, services, or facilities described in the application are critical and essential to an...
10 CFR 216.4 - Evaluation by DOE of applications.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Energy DEPARTMENT OF ENERGY OIL MATERIALS ALLOCATION AND PRIORITY PERFORMANCE UNDER CONTRACTS OR ORDERS... described supplies of materials and equipment, services, or facilities are critical and essential to the... and equipment, services, or facilities described in the application are critical and essential to an...
Benchmarking the FCI at Illinois State's Residential Life.
ERIC Educational Resources Information Center
Cain, David A.
1998-01-01
Describes how Office of Residential Life at one university met maintenance challenges facing its residential and food-service facilities. Discusses study conducted in 1992 to evaluate widespread management practices and addresses its findings, including six recommended practices. Examines development and implementation of facilities audit,…
10 CFR 216.4 - Evaluation by DOE of applications.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Energy DEPARTMENT OF ENERGY OIL MATERIALS ALLOCATION AND PRIORITY PERFORMANCE UNDER CONTRACTS OR ORDERS... described supplies of materials and equipment, services, or facilities are critical and essential to the... and equipment, services, or facilities described in the application are critical and essential to an...
Space Availability in Wyoming's Vocational Education Facilities.
ERIC Educational Resources Information Center
Ryan, Susan K.
The space availability in public school vocational education facilities in Wyoming was determined and evaluated. Results were based on teacher response. The service areas involved were vocational agriculture, business and office education, health occupations education, home economics education, marketing and distributive education, and trade and…
78 FR 38983 - Agency Information Collection Activities: Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-28
... specialties: clinical nurse specialist, nurse practitioner, certified nurse anesthetist, certified nurse... a decision aid for dialysis facility selection; (2) aid facilities with their internal quality... a new OMB control number); Title of Information Collection: Evaluation of the Graduate Nurse...
Thermal Storage Process and Components Laboratory | Energy Systems
Integration Facility | NREL Process and Components Laboratory Thermal Storage Process and Components Laboratory The Energy Systems Integration Facility's Thermal Systems Process and Components Laboratory supports research and development, testing, and evaluation of new thermal energy storage systems
Development and use of hydrogen-air torches in an altitude facility
NASA Technical Reports Server (NTRS)
Lottig, Roy A.; Huber, Gary T.
1993-01-01
A hydrogen-air ignition torch concept that had been used successfully in two rocket engine test facilities to consume excess hydrogen in their exhausters at atmospheric conditions was experimentally evaluated and developed in an altitude test facility at NASA Lewis Research Center. The idea was to use several of these torches in conjunction with hydrogen detectors and dilution air to prevent excess accumulation of unburned hydrogen or mixtures of hydrogen and air exceeding the sea-level lower flammability limit in the altitude facility exhaust system during hydrogen-fueled propulsion system tests. The torches were evaluated for a range of fuel-to-air ratios from 0.09 to 0.39 and for a range of exit diameters from 19/64 to 49/64 in. From the results of these tests a torch geometry and a fuel-to-air ratio were selected that produced a reasonably sized torch exhaust flame for consumption of unburned hydrogen at altitude pressures from sea level to 4 psia.
The development of the Canadian Mobile Servicing System Kinematic Simulation Facility
NASA Technical Reports Server (NTRS)
Beyer, G.; Diebold, B.; Brimley, W.; Kleinberg, H.
1989-01-01
Canada will develop a Mobile Servicing System (MSS) as its contribution to the U.S./International Space Station Freedom. Components of the MSS will include a remote manipulator (SSRMS), a Special Purpose Dexterous Manipulator (SPDM), and a mobile base (MRS). In order to support requirements analysis and the evaluation of operational concepts related to the use of the MSS, a graphics based kinematic simulation/human-computer interface facility has been created. The facility consists of the following elements: (1) A two-dimensional graphics editor allowing the rapid development of virtual control stations; (2) Kinematic simulations of the space station remote manipulators (SSRMS and SPDM), and mobile base; and (3) A three-dimensional graphics model of the space station, MSS, orbiter, and payloads. These software elements combined with state of the art computer graphics hardware provide the capability to prototype MSS workstations, evaluate MSS operational capabilities, and investigate the human-computer interface in an interactive simulation environment. The graphics technology involved in the development and use of this facility is described.
DOE handbook: Guide to good practices for training and qualification of maintenance personnel
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-03-01
The purpose of this Handbook is to provide contractor training organizations with information that can be used to verify the adequacy of and/or modify existing maintenance training programs, or to develop new training programs. This guide, used in conjunction with facility-specific job analyses, provides a framework for training and qualification programs for maintenance personnel at DOE reactor and nonreactor nuclear facilities. Recommendations for qualification are made in four areas: education, experience, physical attributes, and training. The functional positions of maintenance mechanic, electrician, and instrumentation and control technician are covered by this guide. Sufficient common knowledge and skills were found tomore » include the three disciplines in one guide to good practices. Contents include: qualifications; on-the-job training; trainee evaluation; continuing training; training effectiveness evaluation; and program records. Appendices are included which relate to: administrative training; industrial safety training; fundamentals training; tools and equipment training; facility systems and component knowledge training; facility systems and component skills training; and specialized skills training.« less
Validation of cleaning method for various parts fabricated at a Beryllium facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, Cynthia M.
This study evaluated and documented a cleaning process that is used to clean parts that are fabricated at a beryllium facility at Los Alamos National Laboratory. The purpose of evaluating this cleaning process was to validate and approve it for future use to assure beryllium surface levels are below the Department of Energy’s release limits without the need to sample all parts leaving the facility. Inhaling or coming in contact with beryllium can cause an immune response that can result in an individual becoming sensitized to beryllium, which can then lead to a disease of the lungs called chronic berylliummore » disease, and possibly lung cancer. Thirty aluminum and thirty stainless steel parts were fabricated on a lathe in the beryllium facility, as well as thirty-two beryllium parts, for the purpose of testing a parts cleaning method that involved the use of ultrasonic cleaners. A cleaning method was created, documented, validated, and approved, to reduce beryllium contamination.« less
An evaluation of three experimental processes for two-dimensional transonic tests
NASA Technical Reports Server (NTRS)
Zuppardi, Gennaro
1989-01-01
The aerodynamic measurements in conventional wind tunnels usually suffer from the interference effects of the sting supporting the model and the test section walls. These effects are particularly severe in the transonic regime. Sting interference effects can be overcome through the Magnetic Suspension technique. Wall effects can be alleviated by: testing airfoils in conventional, ventilated tunnels at relatively small model to tunnel size ratios; treatment of the tunnel wall boundary layers; or by utilization of the Adaptive Wall Test Section (AWTS) concept. The operating capabilities and results from two of the foremost two-dimensional, transonic, AWTS facilities in existence are assessed. These facilities are the NASA 0.3-Meter Transonic Cryogenic Tunnel and the ONERA T-2 facility located in Toulouse, France. In addition, the results derived from the well known conventional facility, the NAE 5 ft x 5 ft Canadian wind tunnel will be assessed. CAST10/D0A2 Airfoil results will be used in all of the evaluations.
Environmental Health Practice: Statistically Based Performance Measurement
Enander, Richard T.; Gagnon, Ronald N.; Hanumara, R. Choudary; Park, Eugene; Armstrong, Thomas; Gute, David M.
2007-01-01
Objectives. State environmental and health protection agencies have traditionally relied on a facility-by-facility inspection-enforcement paradigm to achieve compliance with government regulations. We evaluated the effectiveness of a new approach that uses a self-certification random sampling design. Methods. Comprehensive environmental and occupational health data from a 3-year statewide industry self-certification initiative were collected from representative automotive refinishing facilities located in Rhode Island. Statistical comparisons between baseline and postintervention data facilitated a quantitative evaluation of statewide performance. Results. The analysis of field data collected from 82 randomly selected automotive refinishing facilities showed statistically significant improvements (P<.05, Fisher exact test) in 4 major performance categories: occupational health and safety, air pollution control, hazardous waste management, and wastewater discharge. Statistical significance was also shown when a modified Bonferroni adjustment for multiple comparisons was performed. Conclusions. Our findings suggest that the new self-certification approach to environmental and worker protection is effective and can be used as an adjunct to further enhance state and federal enforcement programs. PMID:17267709
A free-piston Stirling engine/linear alternator controls and load interaction test facility
NASA Technical Reports Server (NTRS)
Rauch, Jeffrey S.; Kankam, M. David; Santiago, Walter; Madi, Frank J.
1992-01-01
A test facility at LeRC was assembled for evaluating free-piston Stirling engine/linear alternator control options, and interaction with various electrical loads. This facility is based on a 'SPIKE' engine/alternator. The engine/alternator, a multi-purpose load system, a digital computer based load and facility control, and a data acquisition system with both steady-periodic and transient capability are described. Preliminary steady-periodic results are included for several operating modes of a digital AC parasitic load control. Preliminary results on the transient response to switching a resistive AC user load are discussed.
Calvo, Richard Yee; Lindsay, Suzanne P; Edland, Steven D; Macera, Caroline A; Wingard, Deborah L; Ohno-Machado, Lucila; Sise, Michael J
2016-03-01
Pre-existing chronic conditions (PECs) pose a unique problem for the care of aging trauma populations. However, the relationships between specific conditions and outcomes after injury are relatively unknown. Evaluation of trauma patients is further complicated by their discharge to care facilities, where mortality risk remains high. Traditional approaches for evaluating in-hospital mortality do not account for the discharge of at-risk patients, which constitutes a competing risk event to death. The objective of this study was to evaluate associations between 40 PECs and two clinical outcomes in the context of competing risks among older trauma patients. This retrospective study evaluated blunt-injured patients aged 55 years and older admitted to a level I trauma centre in 2006-2012. Outcomes were hospital length of stay (HLOS) and in-hospital mortality. Survivors were classified as discharges home or discharges to care facilities. Competing risks regression was used to evaluate each PEC with in-hospital mortality, accounting for discharges to care facilities as competing events. Competing risk estimates were compared to Cox model estimates, for which all survivors to discharge were non-events. Analyses were stratified using injury-based mortality risk at a 50% cutpoint (high versus low). Among 4653 patients, 176 died in-hospital, 3059 were discharged home, and 1418 were discharged to a care facility. Most patients (98%) were classified with a low mortality risk. Only haemophilia and coagulopathy were consistently associated with longer HLOS. In the low-risk subgroup, in-hospital mortality was most strongly associated with liver diseases, haemophilia, and coagulopathy. In the high-risk group, Parkinson's disease, depression, and cancers showed the strongest associations. Accounting for the competing event altered estimates for 12 of 19 significant conditions. Excess mortality among patients expected to survive their injuries may be attributable to complications resulting from PECs. Discharges to care facilities constitute a bias in the evaluation of in-hospital mortality and should be considered for the accurate calculation of risk. In conjunction with injury measures, consideration of PECs provides physicians with a foundation to plan clinical decisions in older trauma patients. Copyright © 2015 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sullivan, Robert; Abplanalp, Jennifer M.
2015-03-01
This report presents the results of a study conducted to document the visibility and visual characteristics of the Ivanpah Solar Electric Generating System (ISEGS), a utility-scale solar power tower facility located on land administered by the U.S. Department of the Interior Bureau of Land Management in southern California. Study activities consisted of field observations of the ISEGS facility and comparison of the observations made in the field with the visual contrast assessments and visual simulations in the ISEGS Final Environmental Impact Statement (Final EIS) and supporting documents created prior to ISEGS construction. Field observations of ISEGS were made from 19more » locations within 35 mi (56 km) of the facility in the course of one week in September 2014. The study results established that reflected sunlight from the receivers was the primary source of visual contrast from the operating ISEGS facility. The ISEGS facility was found to be a major source of visual contrast for all observations up to 20 mi (32 km), and was easily visible at 35 mi. Glare from individual heliostats was frequently visible, and often brighter than the reflected light from the receivers. Heliostat glare caused discomfort for one or more viewers at distances up to 20 mi. The ISEGS power blocks were brightly lit at night, and were conspicuous at the observation distance of approximately 6 mi (10 km). The facility is substantially brighter and is seen more clearly in the field than in photographs of the facility or in the prepared simulations, which were based on photographs. The simulations of the ISEGS facility in the Final EIS, which were evaluated as part of this study, sometimes lacked spatial accuracy and realism. The evaluated simulations generally under-represented the actual visual contrast from the project, and some of the contrast ratings in the Final EIS predicted substantially lower levels of visual contrast than were actually observed for the operating facility.« less
Oseni, Lolade; Mtimuni, Angella; Sethi, Reena; Rashidi, Tambudzai; Kachale, Fannie; Rawlins, Barbara; Gupta, Shivam
2017-01-01
This analysis seeks to identify strengths and gaps in the existing facility capacity for intrapartum and immediate postpartum fetal and neonatal care, using data collected as a part of Malawi’s Helping Babies Breath program evaluation. From August to September 2012, the Maternal and Child Health Integrated Program (MCHIP) conducted a cross-sectional survey in 84 Malawian health facilities to capture current health facility service availability and readiness and health worker capacity and practice pertaining to labor, delivery, and immediate postpartum care. The survey collected data on availability of equipment, supplies, and medications, and health worker knowledge and performance scores on intrapartum care simulation and actual management of real clients at a subset of facilities. We ran linear regression models to identify predictors of high simulation performance of routine delivery care and management of asphyxiated newborns across all facilities surveyed. Key supplies for infection prevention and thermal care of the newborn were found to be missing in many of the surveyed facilities. At the health center level, 75% had no clinician trained in basic emergency obstetric care or newborn care and 39% had no midwife trained in the same. We observed that there were no proportional increases in available transport and staff at a facility as catchment population increased. In simulations of management of newborns with breathing problems, health workers were able to complete a median of 10 out of 16 tasks for a full-term birth case scenario and 20 out of 30 tasks for a preterm birth case scenario. Health workers who had more years of experience appeared to perform worse. Our study provides a benchmark and highlights gaps for future evaluations and studies as Malawi continues to make strides in improving facility-based care. Further progress in reducing the burden of neonatal and fetal death in Malawi will be partly predicated on guaranteeing properly equipped and staffed facilities in addition to ensuring the presence of skilled health workers. PMID:28301484
Kozuki, Naoko; Oseni, Lolade; Mtimuni, Angella; Sethi, Reena; Rashidi, Tambudzai; Kachale, Fannie; Rawlins, Barbara; Gupta, Shivam
2017-01-01
This analysis seeks to identify strengths and gaps in the existing facility capacity for intrapartum and immediate postpartum fetal and neonatal care, using data collected as a part of Malawi's Helping Babies Breath program evaluation. From August to September 2012, the Maternal and Child Health Integrated Program (MCHIP) conducted a cross-sectional survey in 84 Malawian health facilities to capture current health facility service availability and readiness and health worker capacity and practice pertaining to labor, delivery, and immediate postpartum care. The survey collected data on availability of equipment, supplies, and medications, and health worker knowledge and performance scores on intrapartum care simulation and actual management of real clients at a subset of facilities. We ran linear regression models to identify predictors of high simulation performance of routine delivery care and management of asphyxiated newborns across all facilities surveyed. Key supplies for infection prevention and thermal care of the newborn were found to be missing in many of the surveyed facilities. At the health center level, 75% had no clinician trained in basic emergency obstetric care or newborn care and 39% had no midwife trained in the same. We observed that there were no proportional increases in available transport and staff at a facility as catchment population increased. In simulations of management of newborns with breathing problems, health workers were able to complete a median of 10 out of 16 tasks for a full-term birth case scenario and 20 out of 30 tasks for a preterm birth case scenario. Health workers who had more years of experience appeared to perform worse. Our study provides a benchmark and highlights gaps for future evaluations and studies as Malawi continues to make strides in improving facility-based care. Further progress in reducing the burden of neonatal and fetal death in Malawi will be partly predicated on guaranteeing properly equipped and staffed facilities in addition to ensuring the presence of skilled health workers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murray, R.C.
1991-09-01
Policy for addressing natural phenomenon comprises a hierarchy of interrelated documents. The top level of policy is contained in the code of Federal Regulations which establishes the framework and intent to ensure overall safety of DOE facilities when subjected to the effects of natural phenomena. The natural phenomena to be considered include earthquakes and tsunami, winds, hurricanes and tornadoes, floods, volcano effects and seiches. Natural phenomena criteria have been established for design of new facilities; evaluation of existing facilities; additions, modifications, and upgrades to existing facilities; and evaluation criteria for new or existing sites. Steps needed to implement these fourmore » general criteria are described. The intent of these criteria is to identify WHAT needs to be done to ensure adequate protection from natural phenomena. The commentary provides discussion of WHY this is needed for DOE facilities within the complex. Implementing procedures identifying HOW to carry out these criteria are next identified. Finally, short and long term tasks needed to identify the implementing procedure are tabulated. There is an overall need for consistency throughout the DOE complex related to natural phenomena including consistent terminology, policy, and implementation. 1 fig, 6 tabs.« less
Townend, William K; Cheeseman, Christopher R
2005-10-01
This paper presents guidelines that can be used by managers of healthcare facilities to evaluate and assess the quality of resources and waste management at their facilities and enabling the principles of sustainable development to be addressed. The guidelines include the following key aspects which need to be considered when completing an assessment. They are: (a) general management; (b) social issues; (c) health and safety; (d) energy and water use; (e) purchasing and supply; (f) waste management (responsibility, segregation, storage and packaging); (g) waste transport; (h) recycling and re-use; (i) waste treatment; and (j) final disposal. They identify actions required to achieve a higher level of performance which can readily be applied to any healthcare facility, irrespective of the local level of social, economic and environmental development. The guidelines are presented, and the characteristics of facilities associated with sustainable (level 4) and unsustainable (level 0) healthcare resource and wastes management are outlined. They have been used to assess a major London hospital, and this highlighted a number of deficiencies in current practice, including a lack of control over purchasing and supply, and very low rates of segregation of municipal solid waste from hazardous healthcare waste.
1987-09-01
AD-AI6 442 ANNUAL DATA SUMMARY AND CLINATOLOGICAL EVALUATION CEC I/ (COASTAL ENGINEERI.. (U) COASTAL ENGINEERING RESEARCH CENTER VICKSBURG NS H C ...MILLER ET RL. SEP 87 UNL ASSIF IED C RC-TR-87-i-L-1 F/0G/3 Mmsomommosmsss EmhhhmmmmmhEhEshhhhEhBhhE .EhI-EllhhlhhI mll/I/I l/I/u -1 I.I I ’ 22 I 1.8...SUMMARY AND ofEgier CLIMATOLOGICAL EVALUATION CERC FIELD RESEARCH FACILITY, 1985 NVolume I MAIN TEXT AND APPENDIXES A AND B, by ,, U Herman C . Miller
Facility for the evaluation of space communications and related systems
NASA Technical Reports Server (NTRS)
Kerczewski, Robert J.; Svoboda, James S.; Kachmar, Brian A.
1995-01-01
NASA Lewis Research Center's Communications Projects Branch has developed a facility for the evaluation of space communications systems and related types of systems, called the Advanced Space Communications (ASC) Laboratory. The ASC Lab includes instrumentation, testbed hardware, and experiment control and monitor software for the evaluation of components, subsystems, systems, and networks. The ASC lab has capabilities to perform radiofrequency (RF), microwave, and millimeter-wave characterizations as well as measurements using low, medium, or high data rate digital signals. In addition to laboratory measurements, the ASC Lab also includes integrated satellite ground terminals allowing experimentation and measurements accessing operational satellites through real space links.
NASA Technical Reports Server (NTRS)
Krupa, Debra T.; Gosbee, John; Murphy, Linda; Kizzee, Victor D.
1991-01-01
The purpose is to evaluate the prototype Advanced Life Support (ALS) Pack which was developed for the Health Maintenance Facility (HMF). This pack will enable the Crew Medical Officer (CMO) to have ready access to advanced life support supplies and equipment for time critical responses to any situation within the Space Station Freedom. The objectives are: (1) to evaluate the design of the pack; and (2) to collect comments for revision to the design of the pack. The in-flight test procedures and other aspects of the KC-135 parabolic test flight to simulate weightlessness are presented.
Lorv, Bailey; Horodyski, Robin; Welton, Cynthia; Vail, John; Simonetto, Luca; Jokanovic, Danilo; Sharma, Richa; Mahoney, Angela Rea; Savoy-Bird, Shay; Bains, Shalu
2017-01-01
There is increasing awareness of the importance of medical device reprocessing (MDR) for the provision of safe patient care. Although industry service standards are available to guide MDR practices, there remains a lack of published key performance indicators (KPIs) and targets that are necessary to evaluate MDR quality for feedback and improvement. This article outlines the development of an initial framework that builds on established guidelines and includes service standards, KPIs and targets for evaluating MDR operations. This framework can support healthcare facilities in strengthening existing practices and enables a platform for collaboration towards better MDR performance management.
Evaluating School Facilities in Brazil
ERIC Educational Resources Information Center
Ornstein, Sheila Walbe; Moreira, Nanci Saraiva
2008-01-01
Brazil's Sao Paulo Metropolitan Region is conducting a performance evaluation pilot study at three schools serving disadvantaged populations. The objective is first to test methods which can facilitate Post Occupancy Evaluations (POEs) and then to carry out the evaluations. The preliminary results are provided below.
This innovative technology evaluation report (ITER) summarized the results of an evaluation of a surfactant-enhanced extraction technology. This evaluation was conducted under a bilateral agreement between the United States (U.S.) Environmental Protection Agency (EPA) Superfund ...
THE CONCEPTUAL DESIGN ASSESSMENT FOR THE CO-FIRING OF BIO-REFINERY SUPPLIED LIGNIN PROJECT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ted Berglund; Jeffrey T. Ranney; Carol L. Babb
2001-07-01
The major aspects of this project are proceeding toward completion. Prior to this quarter, design criteria, tentative site selection, facility layout, and preliminary facility cost estimates were completed and issued. Processing of bio-solids was completed, providing material for the pilot operations. Pilot facility design, equipment selection, and modification were completed during the fourth quarter of 2000. Initial pilot facility shakedown was completed during the fourth quarter. After some unavoidable delays, a suitable representative supply of MSW feed material was procured. During this first quarter of 2001, shredding of the feed material and final feed conditioning were completed. Pilot facility hydrolysismore » production was completed to produce lignin for co-fire testing. During this quarter, TVA completed the washing and dewatering of the lignin material produced from the MSW hydrolysis. Seven drums of lignin material were washed to recover the acid and sugar from the lignin and provide an improved fuel for steam generation. Samples of both the lignin and bio-solids fuel materials for co-fire testing were sent to the co-fire facility (EERC) for evaluation. After sample evaluation, EERC approved sending the material and all of the necessary fuel for testing was shipped to EERC. EERC has requested and will receive coal typical of the fuel to the TVA-Colbert boilers. This material will be used at EERC as baseline material and for mixing with the bio-fuel for combustion testing. EERC combustion testing of the bio based fuels is scheduled to begin in August of 2001. The TVA-Colbert facility has neared completion of the task to evaluate the co-location of the Masada facility on the operation of the power generation facility. The TVA-Colbert fossil plant is fully capable of providing a reliable steam supply. The preferred steam supply connection points and steam pipeline routing have been identified. The environmental review of the pipeline routing has been completed and no major impacts have been identified. Detailed assessment of steam export impacts on the Colbert boiler system have been completed and a cost estimate for steam supply system was completed. The cost estimate and the output and heat rate impacts will be used to determine a preliminary price for the exported steam. The preliminary steam price will be determined in the next quarter.« less
Harding, Krystal M; Dyo, Melissa; Goebel, Joy R; Gorman, Nik; Levine, Julia
2016-08-01
Malnutrition among skilled nursing facility (SNF) patients can lead to hospital readmissions and multiple complications. To evaluate the effect of an existing malnutrition screening and management program on prealbumin levels of patients in skilled nursing facilities. A retrospective design was used to evaluate baseline admission data including a prealbumin level. Patients with malnutrition received an oral protein supplement according to protocol. A comparison prealbumin level was obtained at 30days. Nearly half of the patients were severely malnourished on admission. Patients receiving the prescribed protocol had significantly increased prealbumin levels at 30days than those patients that did not receive the protocol as prescribed. A prealbumin level upon admission at a SNF could represent a reliable tool to evaluate malnutrition. Initiation of an early malnutrition screening and protein supplement program in this setting is essential to identifying and treating at-risk patients before complications occur. Copyright © 2015 Elsevier Inc. All rights reserved.
Use of personal protective equipment for respiratory protection.
Sargent, Edward V; Gallo, Frank
2003-01-01
Management of hazards in biomedical research facilities requires the application of the traditional industrial hygiene responsibilities of anticipation, recognition, evaluation, and control to characterize the work environment, evaluate tasks and equipment, identify hazards, define exposure groups, and recommend controls. Generally, the diversity and unique characteristics of hazards faced by laboratory and animal facility employees and the short-term and low-level nature of the exposures factor into the selection of proper exposure control measures in the laboratory. The proper selection of control measures is based on a hierarchy of elimination and minimization by engineering controls, followed last by personal protective equipment when exposures cannot be eliminated. Once it is decided that personal protective equipment is needed, specific regulations and guidelines define safety standards for research facilities, including the elements of a sound respiratory protection program. These elements include respirator selection (including appropriate protection factors), medical evaluation, fit testing, training, inspection, maintenance and care, quality, quantity and flow of breathing air, and routine and emergency use procedures.
Energy Systems Sensor Laboratory | Energy Systems Integration Facility |
NREL Sensor Laboratory Energy Systems Sensor Laboratory The Energy Systems Integration Facility's Energy Systems Sensor Laboratory is designed to support research, development, testing, and evaluation of advanced hydrogen sensor technologies to support the needs of the emerging hydrogen
Optimization Evaluation, General Motors Former AC Rochester Facility, Sioux City, Iowa
The General Motors (GM) Former AC Rochester Facility (site) is located within the valley of the Missouri River in Sioux City, Iowa and is bounded by a steep loess bluff to the north, commercial properties to the east, and undeveloped properties to the...
CEFPI's Heart to Honduras Educational Facilities Team.
ERIC Educational Resources Information Center
Jennings, James E.
1997-01-01
Describes efforts by the Council of Educational Facility Planners International to evaluate and modernize poor, rural schools in Honduras. A positive reaction to the visitation by government officials and teachers is revealed leading to the planned use of a model school program to guide school transformation. (GR)
DOT National Transportation Integrated Search
1983-05-01
This four volume report consists of a data base describing "surrogate" automobile and truck manufacturing plants developed as part of a methodology for evaluating capital investment requirements in new manufacturing facilities to build new fleets of ...
NASA Technical Reports Server (NTRS)
Ladbury, R.; Reed, R. A.; Marshall, P. W.; LaBel, K. A.; Anantaraman, R.; Fox, R.; Sanderson, D. P.; Stolz, A.; Yurkon, J.; Zeller, A. F.;
2004-01-01
The performance of Michigan State University's Single-Event Effects Test Facility (SEETF) during its inaugural runs is evaluated. Beam profiles and other diagnostics are presented, and prospects for future development and testing are discussed.
CLINICAL PROGRAMS FOR MENTALLY RETARDED CHILDREN, A LISTING.
ERIC Educational Resources Information Center
HORMUTH, RUDOLF P.
THIS IS THE SEVENTH LISTING OF SPECIAL CLINICAL FACILITIES FOR MENTALLY HANDICAPPED CHILDREN COMPILED BY THE CHILDREN'S BUREAU, DEPARTMENT OF HEALTH, EDUCATION, AND WELFARE. THE CLINICS WHICH ARE LISTED CAN BE DEFINED AS OUTPATIENT MEDICAL FACILITIES PROVIDING COMPREHENSIVE EVALUATION, TREATMENT, OR FOLLOWUP SERVICES PRIMARILY TO CHILDREN…
Effects of Psychoeducation for Offenders in a Community Correctional Facility
ERIC Educational Resources Information Center
Liau, Albert K.; Shively, Randy; Horn, Mary; Landau, Jennifer; Barriga, Alvaro; Gibbs, John C.
2004-01-01
The present study provided a randomized outcome evaluation of the psychoeducational component of the EQUIP program. The psychoeducational curriculum was implemented in a community correctional facility for adult felony offenders. The psychoeducational curriculum is designed to remedy offenders' delays in moral judgment maturity, social cognitive…
DOT National Transportation Integrated Search
2018-01-01
This project was initiated by the ODOT District 2 staff who were looking for more efficient ways to heat and operate their maintenance facilities. This especially applied to the idea of using radiant floor heating as an alternative to todays stand...
our cutting-edge research facilities to develop, test, and evaluate wind technologies. License Our advantage of the center's facilities and research and development capabilities. An aerial photo of buildings wind-generated electricity. Companies partner with NREL when they have particular design challenges
Facility fence-line monitoring using passive samplers
In 2009, the U.S. EPA executed a year-long field study at a refinery in Corpus Christi, Texas, to evaluate the use of passive diffusive sampling technology for assessing time-averaged benzene concentrations at the facility fence line. The study utilized 14-day time-integrated Car...
Student Control as a Planning and Design Factor in Educational Facilities.
ERIC Educational Resources Information Center
Lilley, H. Edward
Appropriate school facility design promotes a balance between student freedom and control. This report evaluates research on architectural approaches affecting student control and offers design recommendations. Since 1960, school discipline and vandalism problems have exploded. Senator Birch Bayh's committee reported that certain crimes are…
Environmental Criteria: MR Preschool Day Care Facilities.
ERIC Educational Resources Information Center
Waligura, Randolph L.; And Others
Contributions of the physical environment to the learning process and environmental needs of preschool children are evaluated. Guidelines for the planning and design of preschool day care facilities, especially for mentally retarded and other children with developmental disabilities, are established. The current status and trends in day care…
SETTING UP A LABORATORY AB INITIO IN A REMOTE LOCATION
For many years the USEPA's National Risk Management Research Laboratory in Cincinnati, OH has operated a pilot plant approximately 5 kilometers from its main research facility. Originally, this Tet and Evaluation (T&E) facility was sited to be adjacent to the City of Cincinnati's...
NASA Technical Reports Server (NTRS)
Haviland, J. K.; Herling, W. W.
1978-01-01
The design and construction of an experimental facility for the investigation of scaling effects in propulsive lift configurations are described. The facility was modeled after an existing full size NASA facility which consisted of a coaxial turbofan jet engine with a rectangular nozzle in a blown surface configuration. The flow field of the model facility was examined with and without a simulated wing surface in place at several locations downstream of the nozzle exit plane. Emphasis was placed on obtaining pressure measurements which were made with static probes and surface pressure ports connected via plastic tubing to condenser microphones for fluctuating measurements. Several pressure spectra were compared with those obtained from the NASA facility, and were used in a preliminary evaluation of scaling laws.
Environmental review of Potomac Electric Power Company's proposed Station H Element I
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1990-04-01
The report has been conducted to evaluate the potential impacts to environmental and cultural resources from the proposed construction and operation of Element I (the combustion turbine portion) of the Station H power plant facility at Potomac Electric Power Company's Dickerson site. This review also presents an evaluation of air quality impacts of Elements I and II (combustion turbine and combined cycle components of the facility) and an assessment of compliance with state and Federal air quality regulations (primarily the ambient air quality standards and the air quality impact requirements of PSD regulations). Results of the Environmental Review analysis aremore » used as the basis for establishing preliminary recommended licensing conditions for operating the proposed facility. These recommendations are also included in the report.« less
Lessons Learned from Comprehensive Energy and Water Evaluations at U.S. Army Campus Installations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woodward, James C.; Dahowski, Robert T.
The U.S. Department of Energy’s Pacific Northwest National Laboratory has engaged in a multi-year collaboration with the U.S. Army to support comprehensive energy and water evaluations at large Army campus installations. Initiated to help the Army achieve compliance with facility evaluation requirements dictated by the Energy Independence and Security Act of 2007, this effort has resulted in the evaluation of 530 buildings at 14 installations across the U.S., and the identification of annual savings potential of over 212 billion Btu of energy and 29 million gallons of water. This paper highlights the nature of the evaluation process applied at thesemore » Army installations and discusses a number of key findings that can be considered for ongoing and future evaluations at Army and other federal agency facilities, particularly those buildings within campus settings.« less
A dynamic vulnerability evaluation model to smart grid for the emergency response
NASA Astrophysics Data System (ADS)
Yu, Zhen; Wu, Xiaowei; Fang, Diange
2018-01-01
Smart grid shows more significant vulnerability to natural disasters and external destroy. According to the influence characteristics of important facilities suffered from typical kinds of natural disaster and external destroy, this paper built a vulnerability evaluation index system of important facilities in smart grid based on eight typical natural disasters, including three levels of static and dynamic indicators, totally forty indicators. Then a smart grid vulnerability evaluation method was proposed based on the index system, including determining the value range of each index, classifying the evaluation grade standard and giving the evaluation process and integrated index calculation rules. Using the proposed evaluation model, it can identify the most vulnerable parts of smart grid, and then help adopting targeted emergency response measures, developing emergency plans and increasing its capacity of disaster prevention and mitigation, which guarantee its safe and stable operation.
NASA Technical Reports Server (NTRS)
Hoang, Ty; Swenson, Harry N.
1997-01-01
The Traffic Management Advisor (TMA), the sequence and schedule tool of the Center/TRACON Automation System (CTAS), was evaluated at the Fort Worth Center (ZFW) in the summer of 1996. This paper describes the challenges encountered during the various phases of the TMA field evaluation, which included system (hardware and software) installation, personnel training, and data collection. Operational procedures were developed and applied to the evaluation process that would ensure air safety. The five weeks of field evaluation imposed minimal impact on the hosting facility and provided valuable engineering and human factors data. The collection of data was very much an opportunistic affair, due to dynamic traffic conditions. One measure of the success of the TMA evaluation is that, rather than remove TMA after the evaluation until it could be fully implemented, the prototype TMA is in continual use at ZFW as the fully operational version is readied for implementation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Osmond, B.
2002-05-20
Sixty-four scientists from universities, national laboratories, and other research institutions worldwide met to evaluate the feasibility and potential of the Biosphere2 Laboratory (B2L) as an inclusive multi-user scientific facility (i.e., a facility open to researchers from all institutions, according to agreed principles of access) for earth system studies and engineering research, education, and training relevant to the mission of the United States Department of Energy (DOE).
Revalidation of the NASA Ames 11-by 11-Foot Transonic Wind Tunnel with a Commercial Airplane Model
NASA Technical Reports Server (NTRS)
Kmak, Frank J.; Hudgins, M.; Hergert, D.; George, Michael W. (Technical Monitor)
2001-01-01
The 11-By 11-Foot Transonic leg of the Unitary Plan Wind Tunnel (UPWT) was modernized to improve tunnel performance, capability, productivity, and reliability. Wind tunnel tests to demonstrate the readiness of the tunnel for a return to production operations included an Integrated Systems Test (IST), calibration tests, and airplane validation tests. One of the two validation tests was a 0.037-scale Boeing 777 model that was previously tested in the 11-By 11-Foot tunnel in 1991. The objective of the validation tests was to compare pre-modernization and post-modernization results from the same airplane model in order to substantiate the operational readiness of the facility. Evaluation of within-test, test-to-test, and tunnel-to-tunnel data repeatability were made to study the effects of the tunnel modifications. Tunnel productivity was also evaluated to determine the readiness of the facility for production operations. The operation of the facility, including model installation, tunnel operations, and the performance of tunnel systems, was observed and facility deficiency findings generated. The data repeatability studies and tunnel-to-tunnel comparisons demonstrated outstanding data repeatability and a high overall level of data quality. Despite some operational and facility problems, the validation test was successful in demonstrating the readiness of the facility to perform production airplane wind tunnel%, tests.
Virtually-augmented interfaces for tactical aircraft.
Haas, M W
1995-05-01
The term Fusion Interface is defined as a class of interface which integrally incorporates both virtual and non-virtual concepts and devices across the visual, auditory and haptic sensory modalities. A fusion interface is a multi-sensory virtually-augmented synthetic environment. A new facility has been developed within the Human Engineering Division of the Armstrong Laboratory dedicated to exploratory development of fusion-interface concepts. One of the virtual concepts to be investigated in the Fusion Interfaces for Tactical Environments facility (FITE) is the application of EEG and other physiological measures for virtual control of functions within the flight environment. FITE is a specialized flight simulator which allows efficient concept development through the use of rapid prototyping followed by direct experience of new fusion concepts. The FITE facility also supports evaluation of fusion concepts by operational fighter pilots in a high fidelity simulated air combat environment. The facility was utilized by a multi-disciplinary team composed of operational pilots, human-factors engineers, electronics engineers, computer scientists, and experimental psychologists to prototype and evaluate the first multi-sensory, virtually-augmented cockpit. The cockpit employed LCD-based head-down displays, a helmet-mounted display, three-dimensionally localized audio displays, and a haptic display. This paper will endeavor to describe the FITE facility architecture, some of the characteristics of the FITE virtual display and control devices, and the potential application of EEG and other physiological measures within the FITE facility.
Air-kerma evaluation at the maze entrance of HDR brachytherapy facilities.
Pujades, M C; Granero, D; Vijande, J; Ballester, F; Perez-Calatayud, J; Papagiannis, P; Siebert, F A
2014-12-01
In the absence of procedures for evaluating the design of brachytherapy (BT) facilities for radiation protection purposes, the methodology used for external beam radiotherapy facilities is often adapted. The purpose of this study is to adapt the NCRP 151 methodology for estimating the air-kerma rate at the door in BT facilities. Such methodology was checked against Monte Carlo (MC) techniques using the code Geant4. Five different facility designs were studied for (192)Ir and (60)Co HDR applications to account for several different bunker layouts.For the estimation of the lead thickness needed at the door, the use of transmission data for the real spectra at the door instead of the ones emitted by (192)Ir and (60)Co will reduce the lead thickness by a factor of five for (192)Ir and ten for (60)Co. This will significantly lighten the door and hence simplify construction and operating requirements for all bunkers.The adaptation proposed in this study to estimate the air-kerma rate at the door depends on the complexity of the maze: it provides good results for bunkers with a maze (i.e. similar to those used for linacs for which the NCRP 151 methodology was developed) but fails for less conventional designs. For those facilities, a specific Monte Carlo study is in order for reasons of safety and cost-effectiveness.
Xin, Zhao; Tsuda, Toshihide; Doi, Hiroyuki
2017-06-01
We evaluated how exposure to airborne volatile organic compounds emitted from a plastic recycling facility affected nearby residents, in a cross-sectional study. Individuals>10 years old were randomly sampled from 50 households at five sites and given questionnaires to complete. We categorized the subjects by distance from the recycling facility and used this as a proxy measure for pollutant exposure. We sought to improve on a preceding study by generating new findings, improving methods for questionnaire distribution and collection, and refining site selection. We calculated the odds of residents living 500 or 900 m away from the facility reporting mucocutaneous and respiratory symptoms using a reference group of residents 2,800 m away. Self-reported nasal congestion (odds ratio=3.0, 95% confidence interval=1.02-8.8), eczema (5.1, 1.1-22.9), and sore throat (3.9, 1.1-14.1) were significantly higher among residents 500 m from the facility. Those 900 m away were also considerably more likely to report experiencing eczema (4.6, 1.4-14.9). Air pollution was found responsible for significantly increased reports of mucocutaneous and respiratory symptoms among nearby residents. Our findings confirm the effects of pollutants emitted from recycling facilities on residents' health and clarify that study design differences did not affect the results.
Evaluation of aircraft crash hazard at Los Alamos National Laboratory facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Selvage, R.D.
This report selects a method for use in calculating the frequency of an aircraft crash occurring at selected facilities at the Los Alamos National Laboratory (the Laboratory). The Solomon method was chosen to determine these probabilities. Each variable in the Solomon method is defined and a value for each variable is selected for fourteen facilities at the Laboratory. These values and calculated probabilities are to be used in all safety analysis reports and hazards analyses for the facilities addressed in this report. This report also gives detailed directions to perform aircraft-crash frequency calculations for other facilities. This will ensure thatmore » future aircraft-crash frequency calculations are consistent with calculations in this report.« less
Evaluation of Aqua-Ammonia Chiller Technologies and Field Site Installation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zaltash, Abdolreza
2007-09-01
The Naval Facilities Engineering Service Center (NFESC) has sponsored Oak Ridge National Laboratory (ORNL) to review, select, and evaluate advanced, gas-fired, 5-ton, aqua-ammonia, chiller technologies. The selection criteria was that units have COP values of 0.67 or better at Air-conditioning and Refrigeration Institute (ARI) 95 F outdoor rating conditions, an active refrigerant flow control, and a variable-speed condenser fan. These features are expected to allow these units to operate at higher ambient temperatures (up to the maximum operating temperature of 110 F) with minimal degradation in performance. ORNL evaluated three potential manufacturers of advanced, gas-fired, 5-ton, aqua-ammonia chillers-Robur, Ambian, andmore » Cooling Technologies. Unfortunately, Robur did not meet the COP requirements and Cooling Technologies could not deliver a unit to be tested at the U.S. Department of Energy (DOE)-ORNL environmental chamber testing facility for thermally activated heat pumps. This eliminated these two technologies from further consideration, leaving only the Ambian chillers for evaluation. Two Ambian chillers were evaluated at the DOE-ORNL test facility. Overall these chillers operated well over a wide range of ambient conditions with minimal degradation in performance due to several control strategies used such as a variable speed condenser fan, a modulating burner, and active refrigerant flow control. These Ambian pre-commercial units were selected for installation and field testing at three federal facilities. NFESC worked with ORNL to assist with the site selection for installation and evaluation of these chillers. Two sites (ORNL and Naval Surface Warfare Center [NSWC] Corona) had a single chiller unit installed; and at one site (Naval Amphibious Base [NAB] Little Creek), two 5-ton chillers linked together were installed to provide 10 tons of cooling. A chiller link controller developed under this project was evaluated in the field test at Little Creek.« less
Evaluating High School Libraries: Service Is Top Priority.
ERIC Educational Resources Information Center
Baldwin, Margaret
1988-01-01
Discusses the need for ongoing evaluation within high school libraries to ensure adequate library services, which, in turn, enhance the total educational program. The evaluation of library facilities, collections, and staff is discussed, and an annotated bibliography of evaluation tools is provided. (6 references) (CLB)
Bagshaw, Clarence; Isdell, Allen E; Thiruvaiyaru, Dharma S; Brisbin, I Lehr; Sanchez, Susan
2014-06-01
More than thirty years have passed since canine parvovirus (CPV) emerged as a significant pathogen and it continues to pose a severe threat to world canine populations. Published information suggests that flies (Diptera) may play a role in spreading this virus; however, they have not been studied extensively and the degree of their involvement is not known. This investigation was directed toward evaluating the vector capacity of such flies and determining their potential role in the transmission and ecology of CPV. Molecular diagnostic methods were used in this cross-sectional study to detect the presence of CPV in flies trapped at thirty-eight canine facilities. The flies involved were identified as belonging to the house fly (Mucidae), flesh fly (Sarcophagidae) and blow/bottle fly (Calliphoridae) families. A primary surveillance location (PSL) was established at a canine facility in south-central South Carolina, USA, to identify fly-virus interaction within the canine facility environment. Flies trapped at this location were pooled monthly and assayed for CPV using polymerase chain reaction (PCR) methods. These insects were found to be positive for CPV every month from February through the end of November 2011. Fly vector behavior and seasonality were documented and potential environmental risk factors were evaluated. Statistical analyses were conducted to compare the mean numbers of each of the three fly families captured, and after determining fly CPV status (positive or negative), it was determined whether there were significant relationships between numbers of flies captured, seasonal numbers of CPV cases, temperature and rainfall. Flies were also sampled at thirty-seven additional canine facility surveillance locations (ASL) and at four non-canine animal industry locations serving as negative field controls. Canine facility risk factors were identified and evaluated. Statistical analyses were conducted on the number of CPV cases reported within the past year to determine the correlation of fly CPV status (positive or negative) for each facility, facility design (open or closed), mean number of dogs present monthly and number of flies captured. Significant differences occurred between fly CPV positive vs. negative sites with regard to their CPV case numbers, fly numbers captured, and number of dogs present. At the ASL, a statistically significant relationship was found between PCR-determined fly CPV status (positive or negative) and facility design (open vs. closed). Open-facility designs were likely to have more CPV outbreaks and more likely to have flies testing positive for CPV DNA. Copyright © 2014 Elsevier B.V. All rights reserved.
24 CFR 598.620 - Evaluation, monitoring, and enforcement.
Code of Federal Regulations, 2010 CFR
2010-04-01
... HOUSING AND URBAN DEVELOPMENT COMMUNITY FACILITIES URBAN EMPOWERMENT ZONES: ROUND TWO AND THREE DESIGNATIONS Empowerment Zone Grants § 598.620 Evaluation, monitoring, and enforcement. (a) Progress...
24 CFR 598.620 - Evaluation, monitoring, and enforcement.
Code of Federal Regulations, 2011 CFR
2011-04-01
... HOUSING AND URBAN DEVELOPMENT COMMUNITY FACILITIES URBAN EMPOWERMENT ZONES: ROUND TWO AND THREE DESIGNATIONS Empowerment Zone Grants § 598.620 Evaluation, monitoring, and enforcement. (a) Progress...
Systematic Review of Multidisciplinary Chronic Pain Treatment Facilities
Fashler, Samantha R.; Cooper, Lynn K.; Oosenbrug, Eric D.; Burns, Lindsay C.; Razavi, Shima; Goldberg, Lauren; Katz, Joel
2016-01-01
This study reviewed the published literature evaluating multidisciplinary chronic pain treatment facilities to provide an overview of their availability, caseload, wait times, and facility characteristics. A systematic literature review was conducted using PRISMA guidelines following a search of MEDLINE, PsycINFO, and CINAHL databases. Inclusion criteria stipulated that studies be original research, survey more than one pain treatment facility directly, and describe a range of available treatments. Fourteen articles satisfied inclusion criteria. Results showed little consistency in the research design used to describe pain treatment facilities. Availability of pain treatment facilities was scarce and the reported caseloads and wait times were generally high. A wide range of medical, physical, and psychological pain treatments were available. Most studies reported findings on the percentage of practitioners in different health care professions employed. Future studies should consider using more comprehensive search strategies to survey facilities, improving clarity on what is considered to be a pain treatment facility, and reporting on a consistent set of variables to provide a clear summary of the status of pain treatment facilities. This review highlights important information for policymakers on the scope, demand, and accessibility of pain treatment facilities. PMID:27445618
Ivahnenko, Tamara I.
2017-12-07
Changes in municipal and industrial point-source discharges over time have been an important factor affecting nutrient trends in many of the Nation’s streams and rivers. This report documents how three U.S. Environmental Protection Agency (EPA) national datasets—the Permit Compliance System, the Integrated Compliance Information System, and the Clean Watersheds Needs Survey—were evaluated for use in the U.S. Geological Survey National Water-Quality Assessment project to assess the causes of nutrient trends. This report also describes how a database of total nitrogen load and total phosphorous load was generated for select wastewater treatment facilities in the United States based on information reported in the EPA Clean Watersheds Needs Survey. Nutrient loads were calculated for the years 1978, 1980, 1982, 1984, 1986, 1988, 1990, 1992, 1996, 2000, 2004, 2008, and 2012 based on average nitrogen and phosphorous concentrations for reported treatment levels and on annual reported flow values.The EPA Permit Compliance System (PCS) and Integrated Compliance Information System (ICIS), which monitor point-source facility discharges, together are the Nation’s most spatially comprehensive dataset for nutrients released to surface waters. However, datasets for many individual facilities are incomplete, the PCS/ICIS historical data date back only to 1989, and historical data are available for only a limited number of facilities. Additionally, inconsistencies in facility reporting make it difficult to track or identify changes in nutrient discharges over time. Previous efforts made by the U.S. Geological Survey to “fill in” gaps in the PCS/ICIS data were based on statistical methods—missing data were filled in through the use of a statistical model based on the Standard Industrial Classification code, size, and flow class of the facility and on seasonal nutrient discharges of similar facilities. This approach was used to estimate point-source loads for a single point in time; it was not evaluated for use in generating a consistent data series over time.Another national EPA dataset that is available is the Clean Watersheds Needs Survey (CWNS), conducted every 4 years beginning 1973. The CWNS is an assessment of the capital needs of wastewater facilities to meet the water-quality goals set in the Clean Water Act. Data collected about these facilities include location and contact information for the facilities; population served; flow and treatment level of the facility; estimated capital needs to upgrade, repair, or improve facilities for water quality; and nonpoint-source best management practices.Total nitrogen and total phosphorous load calculations for each of the CWNS years were based on treatment level information and average annual outflow (in million gallons per day) from each of the facilities that had reported it. Treatment levels categories (such as Primary, Secondary, or Advanced) were substituted with average total nitrogen and total phosphorous concentrations for each treatment level based on those reported in literature. The CWNS dataset, like the PCS/ICIS dataset, has years where facilities did not report either a treatment level or an annual average outflow, or both. To fill in the data gaps, simple linear assumptions were made based on each facility’s responses to the survey in years bracketing the data gap or immediately before or after the data gap if open ended. Treatment level and flow data unique to each facility were used to complete the CWNS dataset for that facility.
Pilot Study of Four Selected Groups of Parolees, 1971.
ERIC Educational Resources Information Center
Garay, Bert; And Others
To evaluate the effectiveness of the Vocational Rehabilitation Programs of the Adult Correctional Facilities of the State of Washington, four groups of parolees were reviewed to determine their successful adjustment 18 months after parole. The Adult Correctional Facilities offer training in a variety of vocations, including the following: auto…
The American Combustion Pyretron Thermal Destruction System at the U.S. EPA's Combustion Research Facility. Under the auspices of the Superfund Innovative Technology Evaluation, or SITE, program, a critical assessment was made of the American Combustion Pyretron™ oxygen enha...
Code of Federal Regulations, 2013 CFR
2013-10-01
... Support for Health Care Providers Healthcare Connect Fund § 54.636 Eligible participant-constructed and... proposals. Requests for proposals must provide sufficient detail so that cost-effectiveness can be evaluated... its own network facilities is the most cost-effective option after competitive bidding, pursuant to...
Code of Federal Regulations, 2014 CFR
2014-10-01
... Support for Health Care Providers Healthcare Connect Fund § 54.636 Eligible participant-constructed and... proposals. Requests for proposals must provide sufficient detail so that cost-effectiveness can be evaluated... its own network facilities is the most cost-effective option after competitive bidding, pursuant to...
This paper looks at the impact of enforcement activity on facility-level behavior and derives quantitative estimates of the impact. We measure facility-level behavior as the levels of Biological Oxygen Demand (BOD) and Total Suspended Solids (TSS) pollutant discharges generated b...
DOT National Transportation Integrated Search
1980-09-01
This paper summarizes a decade of research evaluating possible stress effects of work on Air Traffic Control Specialists (ATCSs).Studies were conducted at a variety of large and small air traffic facilities. A visit of several days to each facility w...
1989-09-01
Maintenance Evaluation Team ( MEMET ), stated, in his booklet To Aspire For Excellence, the need for emphasis on product- oriented performance (3:17). Existing...JOAGE - Job Order/Facility Age JOSF - Job Order/Facility Square Feet LSD - Least Significant Difference MEMET - Mechanical Equipment Maintenance
NCSU Food Service Survey Report.
ERIC Educational Resources Information Center
Gracie, Larry W.
Student perception of food service facilities at North Carolina State University was surveyed in 1977. Of 1,100 randomly selected residence hall students, 799 responses were obtained. Respondents were asked to evaluate food service facilities and to report their eating habits. Study was limited to eating habits in their rooms, in campus…
Evaluation of the Kuper-Tuca SX36 snow plow cutting edges.
DOT National Transportation Integrated Search
2010-06-01
For the winter of 2009-2010, the MaineDOT experimented with three sets of the Kuper Tuca SX36 : plow blades. Two of these sets were used in the Region 4, Bangor maintenance facility and one set was : used in the Region 3, Turner facility. : Maine...
Health Resources Statistics; Health Manpower and Health Facilities, 1969.
ERIC Educational Resources Information Center
National Center for Health Statistics (DHEW/PHS), Hyattsville, MD.
Intended to provide current statistics on health manpower and inpatient health facilities for the evaluation, planning, and administration of health programs, data were gathered from college and university records, state licensing records, association membership records, and agencies and establishments that provide health services. About 3.7…
LSS systems planning and performance program
NASA Technical Reports Server (NTRS)
Mckenna, Victoria Jones; Dendy, Michael J.; Naumann, Charles B.; Rice, Sally A.; Weathers, John M.
1993-01-01
This report describes, using viewgraphs, the Marshall Space Flight Center's Large Space Structures Ground Test Facilities located in building 4619. Major topics include the Active Control Evaluation of Systems (ACES) Laboratory; the Control-Structures Interaction/Controls, Astrophysics, and Structures Experiment in Space (CSI/CASES); Advanced Development Facility; and the ACES Guest Investigator Program.
78 FR 14951 - State of Washington; Underground Injection Control (UIC) Program Revision
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-08
... of Ecology to the Energy Facility Site Evaluation Council to issue UIC permits at energy facilities... telephone number for the Library is (206) 553-1289. (2) Washington Department of Ecology, Water Quality... the Environmental Protection Agency, and MOUs between the Department of Ecology and the Department of...
NETL- High-Pressure Combustion Research Facility
None
2018-02-14
NETL's High-Pressure Combustion Facility is a unique resource within the National Laboratories system. It provides the test capabilities needed to evaluate new combustion concepts for high-pressure, high-temperature hydrogen and natural gas turbines. These concepts will be critical for the next generation of ultra clean, ultra efficient power systems.
Deployment and evaluation of an active RFID tracking system for finishing pigs
USDA-ARS?s Scientific Manuscript database
Modern swine facilities were developed mainly based on logistics of feeding and moving animals. In recent years, the public has become increasingly concerned about animal care and well-being. A better understanding of the animal space utilization in current facilities could lead to improved facilit...
Learn about how EPA Region 9, Hawaii’s Department of Health, U.S. Navy, and Defense Logistics Agency are working tprotect human health and the environment at the Red Hill Bulk Fuel Storage Facility in Hawaii.
Integrating Sustainability Programs into the Facilities Capital Planning Process
ERIC Educational Resources Information Center
Buchanan, Susan
2011-01-01
With detailed information about the costs and benefits of potential green investments, educational facilities can effectively evaluate which initiatives will ultimately provide the greatest results over the short and long term. Based on its overall goals, every school, college, or university will have different values and therefore different…
Response to in-depth safety audit of the L Lake sampling station
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gladden, J.B.
1986-10-15
An in-depth safety audit of several of the facilities and operations supporting the Biological Monitoring Program on L Lake was conducted. Subsequent to the initial audit, the audit team evaluated the handling of samples taken for analysis of Naegleria fowleri at the 704-U laboratory facility.
Education Market to Gain Facilities Center
ERIC Educational Resources Information Center
Coll Univ Bus, 1970
1970-01-01
To be completed in 1973, a 34-story Educational Facilities Center (EFC) located in downtown Chicago is intended to effect a liaison between business and education, ... (and) provide an innovative setting for interaction between those who make educational products and equipment and those responsible for evaluating and recommending them."…
A GUIDE FOR EQUIPPING INDUSTRIAL ARTS FACILITIES.
ERIC Educational Resources Information Center
American Industrial Arts Association, Washington, DC. Equipment Guide Committee.
SCHOOL ARCHITECTS, ADMINISTRATORS, PLANNERS, AND INDUSTRIAL ARTS SUPERVISORS AND TEACHERS MAY USE THIS GUIDE IN PLANNING, REVISING, AND EVALUATING FACILITIES. IN THE FIRST PART, HAND TOOLS, MACHINES, AND GENERAL EQUIPMENT ARE LISTED FOR (1) AUTO AND POWER MECHANICS, (2) CERAMICS, (3) DRAFTING, (4) ELECTRICITY-ELECTRONICS, (5) ELEMENTARY, (6)…
Instructional Facility Utilization.
ERIC Educational Resources Information Center
Kalamazoo Valley Community Coll., MI.
Data describing campus facility use for instructional and related purposes for one week of activity in Fall 1978 were collected and evaluated at Kalamazoo Valley Community College. Four measures of space utilization were used: (1) percent of available time used; (2) percent of available space used; (3) percent of scheduled space utilized; and (4)…
48 CFR 27.404-6 - Inspection of data at the contractor's facility.
Code of Federal Regulations, 2010 CFR
2010-10-01
... regarding the limited rights or restricted rights status of the data, or for evaluating work performance... REGULATION GENERAL CONTRACTING REQUIREMENTS PATENTS, DATA, AND COPYRIGHTS Rights in Data and Copyrights 27.404-6 Inspection of data at the contractor's facility. Contracting officers may obtain the right to...
An integrated approach for facilities planning by ELECTRE method
NASA Astrophysics Data System (ADS)
Elbishari, E. M. Y.; Hazza, M. H. F. Al; Adesta, E. Y. T.; Rahman, Nur Salihah Binti Abdul
2018-01-01
Facility planning is concerned with the design, layout, and accommodation of people, machines and activities of a system. Most of the researchers try to investigate the production area layout and the related facilities. However, few of them try to investigate the relationship between the production space and its relationship with service departments. The aim of this research to is to integrate different approaches in order to evaluate, analyse and select the best facilities planning method that able to explain the relationship between the production area and other supporting departments and its effect on human efforts. To achieve the objective of this research two different approaches have been integrated: Apple’s layout procedure as one of the effective tools in planning factories, ELECTRE method as one of the Multi Criteria Decision Making methods (MCDM) to minimize the risk of getting poor facilities planning. Dalia industries have been selected as a case study to implement our integration the factory have been divided two main different area: the whole facility (layout A), and the manufacturing area (layout B). This article will be concerned with the manufacturing area layout (Layout B). After analysing the data gathered, the manufacturing area was divided into 10 activities. There are five factors that the alternative were compared upon which are: Inter department satisfactory level, total distance travelled for workers, total distance travelled for the product, total time travelled for the workers, and total time travelled for the product. Three different layout alternatives have been developed in addition to the original layouts. Apple’s layout procedure was used to study and evaluate the different alternatives layouts, the study and evaluation of the layouts was done by calculating scores for each of the factors. After obtaining the scores from evaluating the layouts, ELECTRE method was used to compare the proposed alternatives with each other and with the existing layout; ELECTRE compares the alternatives based on their concordance and discordance indices. The alternatives were ranked from best to worst where regarding to the layouts concerned with the manufacturing area B.4 is the best alternative.
42 CFR 456.370 - Medical, psychological, and social evaluations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 4 2011-10-01 2011-10-01 false Medical, psychological, and social evaluations. 456...: Intermediate Care Facilities Medical, Psychological, and Social Evaluations and Admission Review § 456.370 Medical, psychological, and social evaluations. (a) Before admission to an ICF or before authorization for...
Integrate Evaluation into the Planning Process.
ERIC Educational Resources Information Center
Camp, William
1985-01-01
In an attempt to correct for limitations in the Program Evaluation and Review Technique-Critical Path Method (PERT-CPM), the Graphical Evaluation and Review Technique (GERT) has been developed. This management tool allows for evaluation during the facilities' development process. Two figures and two references are provided. (DCS)
42 CFR 456.370 - Medical, psychological, and social evaluations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 4 2010-10-01 2010-10-01 false Medical, psychological, and social evaluations. 456...: Intermediate Care Facilities Medical, Psychological, and Social Evaluations and Admission Review § 456.370 Medical, psychological, and social evaluations. (a) Before admission to an ICF or before authorization for...
Alves-Conceição, Vanessa; Silva, Daniel Tenório da; Santana, Vanessa Lima de; Santos, Edileide Guimarães Dos; Santos, Lincoln Marques Cavalcante; Lyra, Divaldo Pereira de
2017-07-25
Polypharmacy is a reality in long-term care facilities. However, number of medications used by the patient should not be the only predictor of a complex pharmacotherapy. Although the level of complexity of pharmacotherapy is considered an important factor that may lead to side effects, there are few studies in this field. The aim of this study was to evaluate the complexity of pharmacotherapy in residents of three long-term care facilities. A cross-sectional study was performed to evaluate the complexity of pharmacotherapy using the protocols laid out in the Medication Regimen Complexity Index instrument in three long-term care facilities in northeastern Brazil. As a secondary result, potential drug interactions, potentially inappropriate medications, medication duplication, and polypharmacy were evaluated. After the assessment, the association among these variables and the Medication Regimen Complexity Index was performed. In this study, there was a higher prevalence of women (64.4%) with a high mean age among the study population of 81.8 (±9.7) years. The complexity of pharmacotherapy obtained a mean of 15.1 points (±9.8), with a minimum of 2 and a maximum of 59. The highest levels of complexity were associated with dose frequency, with a mean of 5.5 (±3.6), followed by additional instructions of use averaging 4.9 (±3.7) and by the dosage forms averaging 4.6 (±3.0). The present study evaluated some factors that complicate the pharmacotherapy of geriatric patients. Although polypharmacy was implicated as a factor directly related to complexity, other indicators such as drug interactions, potentially inappropriate medications, and therapeutic duplication can also make the use of pharmacotherapy in such patients more difficult.
Planning Tool for Strategic Evaluation of Facility Plans - 13570
DOE Office of Scientific and Technical Information (OSTI.GOV)
Magoulas, Virginia; Cercy, Michael; Hall, Irin
2013-07-01
Savannah River National Laboratory (SRNL) has developed a strategic planning tool for the evaluation of the utilization of its unique resources for processing and research and development of nuclear materials. The Planning Tool is a strategic level tool for assessing multiple missions that could be conducted utilizing the SRNL facilities and showcasing the plan. Traditional approaches using standard scheduling tools and laying out a strategy on paper tended to be labor intensive and offered either a limited or cluttered view for visualizing and communicating results. A tool that can assess the process throughput, duration, and utilization of the facility wasmore » needed. SRNL teamed with Newport News Shipbuilding (NNS), a division of Huntington Ingalls Industries, to create the next generation Planning Tool. The goal of this collaboration was to create a simulation based tool that allows for quick evaluation of strategies with respect to new or changing missions, and clearly communicates results to the decision makers. This tool has been built upon a mature modeling and simulation software previously developed by NNS. The Planning Tool provides a forum for capturing dependencies, constraints, activity flows, and variable factors. It is also a platform for quickly evaluating multiple mission scenarios, dynamically adding/updating scenarios, generating multiple views for evaluating/communicating results, and understanding where there are areas of risks and opportunities with respect to capacity. The Planning Tool that has been developed is useful in that it presents a clear visual plan for the missions at the Savannah River Site (SRS). It not only assists in communicating the plans to SRS corporate management, but also allows the area stakeholders a visual look at the future plans for SRS. The design of this tool makes it easily deployable to other facility and mission planning endeavors. (authors)« less
Measuring the quality of child health care at first-level facilities.
Gouws, Eleanor; Bryce, Jennifer; Pariyo, George; Armstrong Schellenberg, Joanna; Amaral, João; Habicht, Jean-Pierre
2005-08-01
Sound policy and program decisions require timely information based on valid and relevant measures. Recent findings suggest that despite the availability of effective and affordable guidelines for the management of sick children in first-level health facilities in developing countries, the quality and coverage of these services remains low. We report on the development and evaluation of a set of summary indices reflecting the quality of care received by sick children in first-level facilities. The indices were first developed through a consultative process to achieve face validity by involving technical experts and policymakers. The definition of evaluation measures for many public health programs stops at this point. We added a second phase in which standard statistical techniques were used to evaluate the content and construct validity of the indices and their reliability, drawing on data sets from the multi-country evaluation of integrated management of childhood illness (MCE) in Brazil, Tanzania and Uganda. The statistical evaluation identified important conceptual errors in the indices arising from the theory-driven expert review. The experts had combined items into inappropriate indicators resulting in summary indices that were difficult to interpret and had limited validity for program decision making. We propose a revised set of summary indices for the measurement of child health care in developing countries that is supported by both expert and statistical reviews and that led to similar programmatic insights across the three countries. We advocate increased cross-disciplinary research within public health to improve measurement approaches. Child survival policymakers, program planners and implementers can use these tools to improve their monitoring and so increase the health impact of investments in health facility care.
1. Credit PSR. This view displays the north and west ...
1. Credit PSR. This view displays the north and west facades of Test Stand "G" (Vibration Facility) as seen when looking east southeast (110°). Test Stand "G" no longer houses the vibrator; it now houses an autoclave due to the changing nature of the testing work. The Vibration Facility was Test Stand "G"'s historic function. Test Stand "E" is at the far right. The Vibration Facility subjected motor and engine assemblies to various vibration patterns in order to simulate flight conditions and evaluate the durability of engine and motor designs. - Jet Propulsion Laboratory Edwards Facility, Test Stand G, Edwards Air Force Base, Boron, Kern County, CA
Facility Management as Part of an Integrated Design of Civil Engineering Structures
NASA Astrophysics Data System (ADS)
Hyben, Ivan; Podmanický, Peter
2014-11-01
The present article deals about facility management, as still relatively young component of an integrated planning and design of buildings. Attention is focused on the area of the proposal, which can greatly affect to amount of future operating costs. Operational efficiency has been divided into individual components and satisfaction with the solution of buildings already constructed was assessed by workers, who are actually dedicated facility management in these organizations. The results were then assessed and evaluated through regression analysis. The aim of this paper is to determine to what extent is desired update project documentation of new buildings from the perspective of facility management.
Haiti: Feasibility of Waste-to-Energy Options at the Trutier Waste Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conrad, M. D.; Hunsberger, R.; Ness, J. E.
2014-08-01
This report provides further analysis of the feasibility of a waste-to-energy (WTE) facility in the area near Port-au-Prince, Haiti. NREL's previous analysis and reports identified anaerobic digestion (AD) as the optimal WTE technology at the facility. Building on the prior analyses, this report evaluates the conceptual financial and technical viability of implementing a combined waste management and electrical power production strategy by constructing a WTE facility at the existing Trutier waste site north of Port-au-Prince.
Technology Readiness Assessment of Department of Energy Waste Processing Facilities
2007-09-11
Must Be Reliable, Robust, Flexible, and Durable 6 EM Is Piloting the TRA/AD2 Process Hanford Waste Treatment Plant ( WTP ) – The Initial Pilot Project...Evaluation WTP can only treat ~ ½ of the LAW in the time it will take to treat all the HLW. • There is a need for tank space that will get more urgent with...Facility before the WTP Pretreatment and High-Level Waste (HLW) Vitrification Facilities are available (Requires tank farm pretreatment capability) TRAs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boe, Stephen J.; Lofy, Peter T.
2003-03-01
This is the third annual report of a multi-year project to operate adult collection and juvenile acclimation facilities on Catherine Creek and the upper Grande Ronde River for Snake River spring chinook salmon. These two streams have historically supported populations that provided significant tribal and non-tribal fisheries. Supplementation using conventional and captive broodstock techniques is being used to restore fisheries in these streams. Statement of Work Objectives for 2000: (1) Participate in implementation of the comprehensive multiyear operations plan for the Grande Ronde Endemic Spring Chinook Supplementation Program (GRESCP). (2) Plan for recovery of endemic summer steelhead populations in Catherinemore » Creek and the upper Grande Ronde River. (3) Ensure proper construction and trial operation of semi-permanent adult and juvenile facilities for use in 2000. (4) Collect summer steelhead. (5) Collect adult endemic spring chinook salmon broodstock. (6) Acclimate juvenile spring chinook salmon prior to release into the upper Grande Ronde River and Catherine Creek. (7) Document accomplishments and needs to permitters, comanagers, and funding agency. (8) Communicate project results to the scientific community. (9) Plan detailed GRESCP Monitoring and Evaluation for future years. (10) Monitor adult population abundance and characteristics of Grande Ronde River spring chinook salmon populations and incidentally-caught summer steelhead and bull trout. (11) Monitor condition, movement, and mortality of spring chinook salmon acclimated at remote facilities. (12) Monitor water quality at facilities. (13) Participate in Monitoring & Evaluation of the captive brood component of the Program to document contribution to the Program.« less
1998-11-16
This notice is to advise interested parties that Brooke Army Medical Center (BAMC) and Wilford Hall Medical Center (WHMC), hereinafter referred to as Destination San Antonio, have been designated the Regional Specialized Treatment Service facilities (STSFs) for DRGs 1, 3, 4, 49, 104-107, 110-111, 191, 209, 491, 286, and 357. The application for the STSF designation was submitted by the Lead Agency for TRICARE Region 6 and approved by the Assistant Secretary of Defense (Health Affairs). The Lead Agent will oversee that the STSFs maintain the quality and standards required for specialized treatment services. DoD beneficiaries residing within a 200-mile radius of Destination San Antonio facilities falling into the above patient category must be evaluated by Destination San Antonio staff before receiving care for these DRGs under direct military care or TRICARE/CHAMPUS cost sharing. Travel and lodging for the patient and, if stated to be medically necessary by a referring physician, for a nonmedical attendant, will be reimbursed by Destination San Antonio facility in accordance with the provisions of the Joint Federal Travel Regulation. Although evaluation in person is preferred, it is possible to conduct the evaluation telephonically if the patient is unable to travel to a Destination San Antonio facility. If the care for these DRGs cannot be performed at the Destination San Antonio facilities, the TRICARE Managed Care Support Contractor for Region 6 will provide a medical necessity review prior to issuance of an Inpatient Care Authorization or Non-availability Statement.
Alvaro, Celeste; Wilkinson, Andrea J; Gallant, Sara N; Kostovski, Deyan; Gardner, Paula
2016-01-01
This post occupancy evaluation (POE) assessed the impact of architectural design on psychosocial well-being among patients and staff in the context of a new complex continuing care and rehabilitation facility. Departing from typical POEs, the hospital design intentions formed the theoretical basis to assess outcomes. Intentions included creating an environment of wellness; enhancing connection to the community, the city, and nature; enhancing opportunities for social interaction; and inspiring activity. A pretest-posttest quasi experiment, including quantitative surveys, assessed the impact of the building design on well-being outcomes across three facilities-the new hospital, the former hospital, and a comparison facility with a similar population. With the exception of connection to neighborhood (for patients) and opportunities to visit with others (for staff) and wayfinding (for patients and staff), impressions of the new hospital mirrored the design intentions relative to the former hospital and the comparison facility among patients and staff. Perceptions of improvement in mental health, self-efficacy in mobility, satisfaction, and interprofessional interactions were enhanced at the new hospital relative to the former hospital, whereas optimism, depressive symptoms, general well-being, burnout, and intention to quit did not vary. Interestingly, patients and staff with favorable impressions of the building design fared better on most well-being-related outcomes relative to those with less favorable impressions. Beyond the value of assessing the impact of the design intentions on outcomes, the approach used in this study would benefit evaluation strategies across a diversity of health and other public and large-scale buildings. © The Author(s) 2015.
SSHAC Level 1 Probabilistic Seismic Hazard Analysis for the Idaho National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Payne, Suzette Jackson; Coppersmith, Ryan; Coppersmith, Kevin
A Probabilistic Seismic Hazard Analysis (PSHA) was completed for the Materials and Fuels Complex (MFC), Advanced Test Reactor (ATR), and Naval Reactors Facility (NRF) at the Idaho National Laboratory (INL). The PSHA followed the approaches and procedures for Senior Seismic Hazard Analysis Committee (SSHAC) Level 1 study and included a Participatory Peer Review Panel (PPRP) to provide the confident technical basis and mean-centered estimates of the ground motions. A new risk-informed methodology for evaluating the need for an update of an existing PSHA was developed as part of the Seismic Risk Assessment (SRA) project. To develop and implement the newmore » methodology, the SRA project elected to perform two SSHAC Level 1 PSHAs. The first was for the Fuel Manufacturing Facility (FMF), which is classified as a Seismic Design Category (SDC) 3 nuclear facility. The second was for the ATR Complex, which has facilities classified as SDC-4. The new methodology requires defensible estimates of ground motion levels (mean and full distribution of uncertainty) for its criteria and evaluation process. The INL SSHAC Level 1 PSHA demonstrates the use of the PPRP, evaluation and integration through utilization of a small team with multiple roles and responsibilities (four team members and one specialty contractor), and the feasibility of a short duration schedule (10 months). Additionally, a SSHAC Level 1 PSHA was conducted for NRF to provide guidance on the potential use of a design margin above rock hazard levels for the Spent Fuel Handling Recapitalization Project (SFHP) process facility.« less
42 CFR 456.5 - Evaluation criteria.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) MEDICAL ASSISTANCE PROGRAMS UTILIZATION CONTROL General Provisions § 456.5 Evaluation criteria. The agency... services. This section does not apply to services in hospitals and mental hospitals. For these facilities...
48 CFR 915.305 - Proposal evaluation.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) Personnel from DOE, other Government agencies, consultants, and contractors, including those who manage or... contractors who operate or manage Government-owned facilities, are to be used as evaluators or advisors...
48 CFR 915.305 - Proposal evaluation.
Code of Federal Regulations, 2012 CFR
2012-10-01
...) Personnel from DOE, other Government agencies, consultants, and contractors, including those who manage or... contractors who operate or manage Government-owned facilities, are to be used as evaluators or advisors...
48 CFR 915.305 - Proposal evaluation.
Code of Federal Regulations, 2014 CFR
2014-10-01
...) Personnel from DOE, other Government agencies, consultants, and contractors, including those who manage or... contractors who operate or manage Government-owned facilities, are to be used as evaluators or advisors...
48 CFR 915.305 - Proposal evaluation.
Code of Federal Regulations, 2013 CFR
2013-10-01
...) Personnel from DOE, other Government agencies, consultants, and contractors, including those who manage or... contractors who operate or manage Government-owned facilities, are to be used as evaluators or advisors...
Shuttle crew escape systems test conducted in JSC Bldg 9A CCT
1987-03-20
Shuttle crew escape systems test is conducted by astronauts Steven R. Nagel (left) and Manley L. (Sonny) Carter in JSC One Gravity Mockup and Training Facilities Bldg 9A crew compartment trainer (CCT). Nagel and Carter are evaluating methods for crew escape during Space Shuttle controlled gliding flight. JSC test was done in advance of tests scheduled for facilities in California and Utah. Here, Carter serves as test subject evaluating egress positioning for the tractor rocket escape method - one of the two systems currently being closely studied by NASA.
Source term evaluation for accident transients in the experimental fusion facility ITER
DOE Office of Scientific and Technical Information (OSTI.GOV)
Virot, F.; Barrachin, M.; Cousin, F.
2015-03-15
We have studied the transport and chemical speciation of radio-toxic and toxic species for an event of water ingress in the vacuum vessel of experimental fusion facility ITER with the ASTEC code. In particular our evaluation takes into account an assessed thermodynamic data for the beryllium gaseous species. This study shows that deposited beryllium dusts of atomic Be and Be(OH){sub 2} are formed. It also shows that Be(OT){sub 2} could exist in some conditions in the drain tank. (authors)
1982-02-01
Improvements to and Construction of Government -Owned Facilities Funded by RDT&E -------------------- 57 Section 8: Project Data for Construction at... Government -Owned Facilities Funded by RDT&E --------------------------. . Section 9: Flight Simulator Programs...653,427 936.167 29 63202N AVIONICS 2 3,314 3,745 3,622 10,342 U 407 26 632n3N A0V HELICOPTER DEV 2 4,577 4,790 U 27 63207N ENVIRONENTAL APPLICATIONS 2
Icing simulation: A survey of computer models and experimental facilities
NASA Technical Reports Server (NTRS)
Potapczuk, M. G.; Reinmann, J. J.
1991-01-01
A survey of the current methods for simulation of the response of an aircraft or aircraft subsystem to an icing encounter is presented. The topics discussed include a computer code modeling of aircraft icing and performance degradation, an evaluation of experimental facility simulation capabilities, and ice protection system evaluation tests in simulated icing conditions. Current research focussed on upgrading simulation fidelity of both experimental and computational methods is discussed. The need for increased understanding of the physical processes governing ice accretion, ice shedding, and iced airfoil aerodynamics is examined.
An assessment of the use of antimisting fuel in turbofan engines
NASA Technical Reports Server (NTRS)
Fiorentino, A.; Desaro, R.; Franz, T.
1980-01-01
The effects of antimisting kerosene on the performance of the components from the fuel system and the combustor of a JT8D aircraft engine were evaluated. The problems associated with antimisting kerosene were identified and the extent of shearing or degradation required to allow the engine components to achieve satisfactory operation were determined. The performance of the combustor was assessed in a high pressure facility and in an altitude relight/cold ignition facility. The performance of the fuel pump and control system was evaluated in an open loop simulation.
Icing simulation: A survey of computer models and experimental facilities
NASA Technical Reports Server (NTRS)
Potapczuk, M. G.; Reinmann, J. J.
1991-01-01
A survey of the current methods for simulation of the response of an aircraft or aircraft subsystem to an icing encounter is presented. The topics discussed include a computer code modeling of aircraft icing and performance degradation, an evaluation of experimental facility simulation capabilities, and ice protection system evaluation tests in simulated icing conditions. Current research focused on upgrading simulation fidelity of both experimental and computational methods is discussed. The need for the increased understanding of the physical processes governing ice accretion, ice shedding, and iced aerodynamics is examined.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyd, Brian K.; Parker, Graham B.; Petersen, Joseph M.
The objective of this demonstration project was to evaluate market-ready retrofit technologies for reducing the energy and water use of multi-load washers in healthcare and hospitality facilities. Specifically, this project evaluated laundry wastewater recycling technology in the hospitality sector and ozone laundry technology in both the healthcare and hospitality sectors. This report documents the demonstration of ozone laundry system installations at the Charleston Place Hotel in Charleston, South Carolina, and the Rogerson House assisted living facility in Boston, Massachusetts.
Skylab parasol material evaluation
NASA Technical Reports Server (NTRS)
Jacobs, S.
1975-01-01
Results of experimental work to evaluate the degradation rate of a parasol that was used as a means of alleviating thermal problems encountered soon after the launch of the Skylab 1 space vehicle are presented. Material selection criteria are discussed; the material chosen is described, and results of tests performed after environmental exposure at five facilities are given. The facilities used for exposure to ultraviolet radiation/thermal-vacuum environments and the equipment used for testing physical properties before and after exposure are described. Comparisons of ground test and flight test data are included.
Meteorology Assessment of Historic Rainfall for Los Alamos During September 2013
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bruggeman, David Alan; Dewart, Jean Marie
2016-02-12
DOE Order 420.1, Facility Safety, requires that site natural phenomena hazards be evaluated every 10 years to support the design of nuclear facilities. The evaluation requires calculating return period rainfall to determine roof loading requirements and flooding potential based on our on-site rainfall measurements. The return period rainfall calculations are done based on statistical techniques and not site-specific meteorology. This and future studies analyze the meteorological factors that produce the significant rainfall events. These studies provide the meteorology context of the return period rainfall events.
Melter Technologies Assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perez, J.M. Jr.; Schumacher, R.F.; Forsberg, C.W.
1996-05-01
The problem of controlling and disposing of surplus fissile material, in particular plutonium, is being addressed by the US Department of Energy (DOE). Immobilization of plutonium by vitrification has been identified as a promising solution. The Melter Evaluation Activity of DOE`s Plutonium Immobilization Task is responsible for evaluating and selecting the preferred melter technologies for vitrification for each of three immobilization options: Greenfield Facility, Adjunct Melter Facility, and Can-In-Canister. A significant number of melter technologies are available for evaluation as a result of vitrification research and development throughout the international communities for over 20 years. This paper describes an evaluationmore » process which will establish the specific requirements of performance against which candidate melter technologies can be carefully evaluated. Melter technologies that have been identified are also described.« less
Facility effluent monitoring plan for the plutonium uranium extraction facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wiegand, D.L.
A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of themore » effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years.« less
O'Bryan, D; Clow, K E; O'Bryan, J; Kurtz, D
1996-01-01
Despite the growth and prevalence of assisted-living facilities, empirical marketing research for these facilities is scarce. The objectives of this study were to determine the relative importance of three sets of evaluation criteria in the initial selection of an assisted-living facility, and determine whether the relative importance of these three sets of criteria differed by gender, marital status, level of household, age, or income of the consumer. Survey responses from 279 households indicates that primary service criteria are relatively more important than facilities amenities or organized social activities in the initial selection of an assisted-living facility. The relative importance of the choice criteria differed markedly by gender of the consumer, but marital status, level of household income, and age of the consumer did not have as great an impact on consumers' choice criteria.
CONCEPTUAL DESIGN ASSESSMENT FOR THE CO-FIRING OF BIO-REFINERY SUPPLIED LIGNIN PROJECT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ted Berglund; Jeffrey T. Ranney; Carol L. Babb
2001-10-01
The major aspects of this project are proceeding toward completion. Prior to this quarter, design criteria, tentative site selection, facility layout, and preliminary facility cost estimates were completed and issued. Processing of bio-solids was completed, providing material for the pilot operations. Pilot facility design, equipment selection, and modification were completed during the fourth quarter of 2000. Initial pilot facility shakedown was completed. After some unavoidable delays, a suitable representative supply of MSW feed material was procured. During this first quarter of 2001, shredding of the feed material and final feed conditioning were completed. Pilot facility hydrolysis production was completed tomore » produce lignin for co-fire testing and the lignin fuel was washed and dewatered. Both the lignin and bio-solids fuel materials for co-fire testing were sent to the co-fire facility (EERC) for evaluation and co-firing. EERC has received coal typical of the fuel to the TVA-Colbert boilers. This material will be used at EERC as baseline material and for mixing with the bio-fuel for combustion testing. EERC combustion testing of the bio-based fuels is scheduled to begin in October of 2001. The TVA-Colbert facility has neared completion of the task to evaluate co-location of the Masada facility on the operation of the power generation facility. The TVA-Colbert fossil plant is fully capable of providing a reliable steam supply. The preferred steam supply connection points and steam pipeline routing have been identified. The environmental review of the pipeline routing has been completed and no major impacts have been identified. Detailed assessment of steam export impacts on the Colbert boiler system have been completed and a cost estimate for steam supply system was completed. The cost estimate and the output and heat rate impacts will be used to determine a preliminary price for the exported steam.« less
Manthalu, Gerald; Yi, Deokhee; Farrar, Shelley; Nkhoma, Dominic
2016-11-01
The Government of Malawi has signed contracts called service level agreements (SLAs) with mission health facilities in order to exempt their catchment populations from paying user fees. Government in turn reimburses the facilities for the services that they provide. SLAs started in 2006 with 28 out of 165 mission health facilities and increased to 74 in 2015. Most SLAs cover only maternal, neonatal and in some cases child health services due to limited resources. This study evaluated the effect of user fee exemption on the utilization of maternal health services. The difference-in-differences approach was combined with propensity score matching to evaluate the causal effect of user fee exemption. The gradual uptake of the policy provided a natural experiment with treated and control health facilities. A second control group, patients seeking non-maternal health care at CHAM health facilities with SLAs, was used to check the robustness of the results obtained using the primary control group. Health facility level panel data for 142 mission health facilities from 2003 to 2010 were used. User fee exemption led to a 15% (P < 0.01) increase in the mean proportion of women who made at least one antenatal care (ANC) visit during pregnancy, a 12% (P < 0.05) increase in average ANC visits and an 11% (P < 0.05) increase in the mean proportion of pregnant women who delivered at the facilities. No effects were found for the proportion of pregnant women who made the first ANC visit in the first trimester and the proportion of women who made postpartum care visits. We conclude that user fee exemption is an important policy for increasing maternal health care utilization. For certain maternal services, however, other determinants may be more important. © The Author 2016. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1994-12-31
This study responds to a request by participants in the Global Environment Facility (GEF) for an independent evaluation of the pilot phase. It profiles the GEF, discusses its policy framework, and reviews project development procedures and the strategies and projects in each of the GEF`s four focal areas. The study concludes that fundamental changes must occur and recommends specific reforms, such as articulating more clearly the GEF`s mandate, objectives, and strategies; addressing deficiencies in meeting its global focus; improving capacities and procedures within implementing agencies for managing the portfolio; and increasing non-government organization (NGO), country and community-level participation.
Autran, Roseanne Gomes; Ramos, Elisabete; Pina, Maria de Fátima de; Santos, Maria Paula
2012-03-01
The built environment can influence sports practice. The objective of this study was to examine the association between proximity (< 500m) to sports facilities and participation in sports. We evaluated 1,175 13-year-olds (54% girls) enrolled in public and private schools in Porto, Portugal. Sports activity was assessed using a self-completed questionnaire. The adolescents' residences and sports facilities were georeferenced. A matrix of distances from each residence to the facilities was calculated. For the majority (87%) of the adolescents, there was at least one sports facility close to their place of residence. No statistically significant differences were found in participation in sports based on proximity to facilities (< 500m vs. > 500m); the proportions were 44% vs. 38% (p = 0.414) in girls and 72% vs. 61% (p = 0.094) in boys. In conclusion, proximity to sports facilities was not significantly associated with participation in sports.
SITE PROGRAM EVALUATION OF THE SONOTECH PULSE COMBUSTION BURNER TECHNOLOGY - TECHNICAL RESULTS
A series of demonstration tests was performed at the Environmental Protection Agency's (EPA's) Incineration Research Facility (IRF) under the Superfund Innovative Technology Evaluation (SITE) program. These tests, twelve in all, evaluated a pulse combustion burner technology dev...
Using GREENSCOPE Indicators for Sustainable Computer-Aided Process Evaluation and Design
Manufacturing sustainability can be increased by educating those who design, construct, and operate facilities, and by using appropriate tools for process evaluation and design. The U.S. Environmental Protection Agency's GREENSCOPE methodology and tool, for evaluation and design ...
15 CFR 2301.17 - Evaluation criteria for construction and planning applications.
Code of Federal Regulations, 2010 CFR
2010-01-01
... PUBLIC TELECOMMUNICATIONS FACILITIES PROGRAM Evaluation and Selection Process § 2301.17 Evaluation... significant diversity in the ownership of, operation of, and participation in public telecommunications... attitudes of diverse listeners by promoting the development of more effective programming strategies...
STORMWATER BEST MANAGEMENT PRACTICES TEST FACILITY - SWALES
The NRMRL swale evaluation is part of a larger collection of long-term research projects that evaluates many Best Management Practices. EPA has ongoing research examining the performance of constructed wet lands, and detention and retention ponds. Other projects will evaluate ra...
Factors promoting resident deaths at aged care facilities in Japan: a review.
Sugimoto, Kentaro; Ogata, Yasuko; Kashiwagi, Masayo
2018-03-01
Due to an increasingly ageing population, the Japanese government has promoted elderly deaths in aged care facilities. However, existing facilities were not designed to provide resident end-of-life care and the proportion of aged care facility deaths is currently less than 10%. Consequently, the present review evaluated the factors that promote aged care facility resident deaths in Japan from individual- and facility-level perspectives to exploring factors associated with increased resident deaths. To achieve this, MEDLINE, CINAHL, Web of Science and Ichushi databases were searched on 23 January 2016. Influential factors were reviewed for two healthcare services (insourcing and outsourcing facilities) as well as external healthcare agencies operating outside facilities. Of the original 2324 studies retrieved, 42 were included in analysis. Of these studies, five focused on insourcing, two on outsourcing, seven on external agencies and observed facility/agency-level factors. The other 28 studies identified individual-level factors related to death in aged care facilities. The present review found that at both facility and individual levels, in-facility resident deaths were associated with healthcare service provision, confirmation of resident/family end-of-life care preference and staff education. Additionally, while outsourcing facilities did not require employment of physicians/nursing staff to accommodate resident death, these facilities required visits by physicians and nursing staff from external healthcare agencies as well as residents' healthcare input. This review also found few studies examining outsourcing facilities. The number of healthcare outsourcing facilities is rapidly increasing as a result of the Japanese government's new tax incentives. Consequently, there may be an increase in elderly deaths in outsourcing healthcare facilities. Accordingly, it is necessary to identify the factors associated with residents' deaths at outsourcing facilities. © 2016 The Authors. Health and Social Care in the Community Published by John Wiley & Sons Ltd.
42 CFR 456.482 - Medical, psychiatric, and social evaluations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 4 2011-10-01 2011-10-01 false Medical, psychiatric, and social evaluations. 456..., psychiatric, and social evaluations. If a facility provides inpatient psychiatric services to a recipient under age 21, the medical, psychiatric, and social evaluations required by §§ 456.170, and 456.370 must...
42 CFR 456.482 - Medical, psychiatric, and social evaluations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 4 2014-10-01 2014-10-01 false Medical, psychiatric, and social evaluations. 456..., psychiatric, and social evaluations. If a facility provides inpatient psychiatric services to a beneficiary under age 21, the medical, psychiatric, and social evaluations required by §§ 456.170, and 456.370 must...
42 CFR 456.482 - Medical, psychiatric, and social evaluations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 4 2013-10-01 2013-10-01 false Medical, psychiatric, and social evaluations. 456..., psychiatric, and social evaluations. If a facility provides inpatient psychiatric services to a beneficiary under age 21, the medical, psychiatric, and social evaluations required by §§ 456.170, and 456.370 must...
42 CFR 456.482 - Medical, psychiatric, and social evaluations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 4 2012-10-01 2012-10-01 false Medical, psychiatric, and social evaluations. 456..., psychiatric, and social evaluations. If a facility provides inpatient psychiatric services to a beneficiary under age 21, the medical, psychiatric, and social evaluations required by §§ 456.170, and 456.370 must...
42 CFR 456.482 - Medical, psychiatric, and social evaluations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 4 2010-10-01 2010-10-01 false Medical, psychiatric, and social evaluations. 456..., psychiatric, and social evaluations. If a facility provides inpatient psychiatric services to a recipient under age 21, the medical, psychiatric, and social evaluations required by §§ 456.170, and 456.370 must...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abernethy, C. Scott; Neitzel, Duane A.; Lusty, E. William
The Bonneville Power Administration (BPA), the United States Bureau of Reclamation (USSR), and the Washington State Department of Ecology (WDOE) are funding the construction and evaluation of fish passage facilities and fish protection facilities at irrigation and hydroelectric diversions in the Yakima River Basin, Washington State. The program provides offsite enhancement to compensate for fish and wildlife losses caused by hydroelectric development throughout the Columbia River Basin, and addresses natural propagation of salmon to help mitigate the impact of irrigation in the Yakima River Basin. This report evaluates the flow characteristics of the screening facilities. Studies consisted of velocity measurementsmore » taken in front of the rotary drum screens and within the fish bypass systems during peak flows. Measurements of approach velocity and sweep velocity were emphasized in these studies; however, vertical velocity was also measured. 5 refs., 18 figs., 15 tabs.« less
Impact of glycolate anion on aqueous corrosion in DWPF and downstream facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mickalonis, J. I.
2015-12-15
Glycolic acid is being evaluated as an alternate reductant in the preparation of high level waste for the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS). During processing, the glycolic acid may not be completely consumed with small quantities of the glycolate anion being carried forward to other high level waste (HLW) facilities. The impact of the glycolate anion on the corrosion of the materials of construction (MoC) throughout the waste processing system has not been previously evaluated. A literature review had revealed that corrosion data were not available for the MoCs in glycolic-bearing solutions applicable tomore » SRS systems. Data on the material compatibility with only glycolic acid or its derivative products were identified; however, data were limited for solutions containing glycolic acid or the glycolate anion.« less
An investigation of networking techniques for the ASRM facility
NASA Technical Reports Server (NTRS)
Moorhead, Robert J., II; Smith, Wayne D.; Thompson, Dale R.
1992-01-01
This report is based on the early design concepts for a communications network for the Advanced Solid Rocket Motor (ASRM) facility being built at Yellow Creek near Iuka, MS. The investigators have participated in the early design concepts and in the evaluation of the initial concepts. The continuing system design effort and any modification of the plan will require a careful evaluation of the required bandwidth of the network, the capabilities of the protocol, and the requirements of the controllers and computers on the network. The overall network, which is heterogeneous in protocol and bandwidth, is being modeled, analyzed, simulated, and tested to obtain some degree of confidence in its performance capabilities and in its performance under nominal and heavy loads. The results of the proposed work should have an impact on the design and operation of the ASRM facility.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mackey, H.E. Jr.
1979-01-01
A review of the literature indicates that a significant body of descriptive information exists concerning the aquatic ecology of Upper Three Runs Creek and Four Mile Creek of the Savannah River Plant south of Aiken, South Carolina. This information is adequate for preparation of an environmental document evaluating these streams. These streams will be impacted by construction and operation of a proposed Defense Waste Processing Facility for solidification of high level defense waste. Potential impacts include (1) construction runoff, erosion, and siltation, (2) effluents from a chemical and industrial waste treatment facility, and (3) radionuclide releases. In order to bettermore » evaluate potential impacts, recommend mitigation methods, and comply with NEPA requirements, additional quantitative biological information should be obtained through implementation of an aquatic baseline program.« less
Cacko, Joachim Aimé; Cissé, Kadari; Pambè, Madeleine Wayack; Compaoré, Rachidatou; Kouanda, Seni
2016-11-01
To assess the implementation and effects of the strategy, introduced in June 2011, of making obstetric kits readily available in health facilities in the Adamaoua region of Cameroon. We conducted a quasi-experimental study using an interrupted time series to assess the effects of the strategy, and a case study to evaluate its implementation. The reviewed data were gathered from 13 health facilities over a period from January 2008 to December 2014. Qualitative data were collected from in-depth interviews. The provision of obstetric kits was effective in the intervention health facilities, although some challenges existed and included lack of staff motivation and rampant illegal practices. The number of deliveries and cesareans increased. There is a need to rethink this strategy, given its gaps and shortcomings. Copyright © 2016. Published by Elsevier Ireland Ltd.
Neutron radiography of irradiated nuclear fuel at Idaho National Laboratory
Craft, Aaron E.; Wachs, Daniel M.; Okuniewski, Maria A.; ...
2015-09-10
Neutron radiography of irradiated nuclear fuel provides more comprehensive information about the internal condition of irradiated nuclear fuel than any other non-destructive technique to date. Idaho National Laboratory (INL) has multiple nuclear fuels research and development programs that routinely evaluate irradiated fuels using neutron radiography. The Neutron Radiography reactor (NRAD) sits beneath a shielded hot cell facility where neutron radiography and other evaluation techniques are performed on these highly radioactive objects. The NRAD currently uses the foil-film transfer technique for imaging fuel that is time consuming but provides high spatial resolution. This study describes the NRAD and hot cell facilities,more » the current neutron radiography capabilities available at INL, planned upgrades to the neutron imaging systems, and new facilities being brought online at INL related to neutron imaging.« less
The NASA atomic oxygen effects test program
NASA Technical Reports Server (NTRS)
Banks, Bruce A.; Rutledge, Sharon K.; Brady, Joyce A.
1988-01-01
The NASA Atomic Oxygen Effects Test Program was established to compare the low earth orbital simulation characteristics of existing atomic oxygen test facilities and utilize the collective data from a multitude of simulation facilities to promote understanding of mechanisms and erosion yield dependence upon energy, flux, metastables, charge, and environmental species. Four materials chosen for this evaluation include Kapton HN polyimide, FEP Teflon, polyethylene, and graphite single crystals. The conditions and results of atomic oxygen exposure of these materials is reported by the participating organizations and then assembled to identify degrees of dependency of erosion yields that may not be observable from any single atomic oxygen low earth orbital simulation facility. To date, the program includes 30 test facilities. Characteristics of the participating test facilities and results to date are reported.
Community residential facilities in mental health services: A ten-year comparison in Lombardy.
Barbato, Angelo; Civenti, Graziella; D'Avanzo, Barbara
2017-06-01
Residential mental health services grew steadily since 2000 in Italy. A reorganisation of residential facilities was implemented in 2007 in Lombardy, introducing supported housing in addition to staffed facilities. We compare the provision and characteristics of residential facilities in the 2007 and 2016. In 2007 there were 3462 beds (35.9/100,000 population) in 276 facilities. In 2016 beds were 4783 (47.8/100,000) in 520 facilities. The increase were unevenly distributed in the public and private sector, and the overall increase was due to a higher increase in the private sector. 72% of beds were in highly supervised facilities in 2007 and 66% in 2016. The public sector managed more facilities with a rehabilitation goal, while the private sector more for long-term accommodation. Mean numbers of beds were higher in facilities managed by the private sector in both years. The 2007 reorganisation and the stop to opening new facilities in the last years were not enough to correct the imbalance between highly supervised and flexible solutions. A wider and more diverse offer might have triggered off an increased demand, rather than a more rational use. Given the costs of highly staffed facilities, and the risk of reproducing custodial models, close evaluation of the use of residential facilities should inform policies. Copyright © 2017 Elsevier B.V. All rights reserved.
Proposal for a new categorization of aseptic processing facilities based on risk assessment scores.
Katayama, Hirohito; Toda, Atsushi; Tokunaga, Yuji; Katoh, Shigeo
2008-01-01
Risk assessment of aseptic processing facilities was performed using two published risk assessment tools. Calculated risk scores were compared with experimental test results, including environmental monitoring and media fill run results, in three different types of facilities. The two risk assessment tools used gave a generally similar outcome. However, depending on the tool used, variations were observed in the relative scores between the facilities. For the facility yielding the lowest risk scores, the corresponding experimental test results showed no contamination, indicating that these ordinal testing methods are insufficient to evaluate this kind of facility. A conventional facility having acceptable aseptic processing lines gave relatively high risk scores. The facility showing a rather high risk score demonstrated the usefulness of conventional microbiological test methods. Considering the significant gaps observed in calculated risk scores and in the ordinal microbiological test results between advanced and conventional facilities, we propose a facility categorization based on risk assessment. The most important risk factor in aseptic processing is human intervention. When human intervention is eliminated from the process by advanced hardware design, the aseptic processing facility can be classified into a new risk category that is better suited for assuring sterility based on a new set of criteria rather than on currently used microbiological analysis. To fully benefit from advanced technologies, we propose three risk categories for these aseptic facilities.
Musa, E.; Cooper, C.; Van den Bergh, R.; Owiti, P.; Baller, A.; Siafa, T.; Woldeyohannes, D.; Shringarpure, K.; Gasasira, A.
2017-01-01
Setting: Recognising the importance of infection prevention and control (IPC), a minimum standards tool (MST) was developed in Liberia to guide the safe (re-) opening and provision of care in health facilities. Objectives: To analyse the implementation of specific IPC measures after the 2014 Ebola virus outbreak between June 2015 and May 2016, and to compare the relative improvements in IPC between the public and private sectors. Design: A retrospective comparative cohort study. Results: We evaluated 723 (94%) of the 769 health facilities in Liberia. Of these, 437 (60%) were public and 286 (40%) were private. There was an overall improvement in the MST scores from a median of 13 to 14 out of a maximum possible score of 16. While improvements were observed in all aspects of IPC in both public and private health facilities, IPC implementation was systematically higher in public facilities. Conclusions: We demonstrate the feasibility of monitoring IPC implementation using the MST checklist in post-Ebola Liberia. Our study shows that improvements were made in key aspects of IPC after 1 year of evaluations and tailored recommendations. We also highlight the need to increase the focus on the private sector to achieve further improvements in IPC. PMID:28744446
Tremblay, N; Musa, E; Cooper, C; Van den Bergh, R; Owiti, P; Baller, A; Siafa, T; Woldeyohannes, D; Shringarpure, K; Gasasira, A
2017-06-21
Setting: Recognising the importance of infection prevention and control (IPC), a minimum standards tool (MST) was developed in Liberia to guide the safe (re-) opening and provision of care in health facilities. Objectives: To analyse the implementation of specific IPC measures after the 2014 Ebola virus outbreak between June 2015 and May 2016, and to compare the relative improvements in IPC between the public and private sectors. Design: A retrospective comparative cohort study. Results: We evaluated 723 (94%) of the 769 health facilities in Liberia. Of these, 437 (60%) were public and 286 (40%) were private. There was an overall improvement in the MST scores from a median of 13 to 14 out of a maximum possible score of 16. While improvements were observed in all aspects of IPC in both public and private health facilities, IPC implementation was systematically higher in public facilities. Conclusions: We demonstrate the feasibility of monitoring IPC implementation using the MST checklist in post-Ebola Liberia. Our study shows that improvements were made in key aspects of IPC after 1 year of evaluations and tailored recommendations. We also highlight the need to increase the focus on the private sector to achieve further improvements in IPC.
Evaluation of the national tuberculosis surveillance program in Haiti
Salyer, S. J.; Fitter, D. L.; Milo, R.; Blanton, C.; Ho, J. L.; Geffrard, H.; Morose, W.; Marston, B. J.
2015-01-01
OBJECTIVE To assess the quality of tuberculosis (TB) surveillance in Haiti, including whether underreporting from facilities to the national level contributes to low national case registration. METHODS We collected 2010 and 2012 TB case totals, reviewed laboratory registries, and abstracted individual TB case reports from 32 of 263 anti-tuberculosis treatment facilities randomly selected after stratification/weighting toward higher-volume facilities. We compared site results to national databases maintained by a non-governmental organization partner (International Child Care [ICC]) for 2010 and 2012, and the National TB Program (Programme National de Lutte contre la Tuberculose, PNLT) for 2012 only. RESULTS Case registries were available at 30/32 facilities for 2010 and all 32 for 2012. Totals of 3711 (2010) and 4143 (2012) cases were reported at the facilities. Case totals per site were higher in site registries than in the national databases by 361 (9.7%) (ICC 2010), 28 (0.8%) (ICC 2012), and 31 (0.8%) cases (PNLT 2012). Of abstracted individual cases, respectively 11.8% and 6.8% were not recorded in national databases for 2010 (n = 323) and 2012 (n = 351). CONCLUSIONS The evaluation demonstrated an improvement in reporting registered TB cases to the PNLT in Haiti between 2010 and 2012. Further improvement in case notification will require enhanced case detection and diagnosis. PMID:26260822
Long Duration Space Materials Exposure (LDSE)
NASA Technical Reports Server (NTRS)
Allen, David; Schmidt, Robert
1992-01-01
The Center on Materials for Space Structures (CMSS) at Case Western Reserve University is one of seventeen Commercial Centers for the Development of Space. It was founded to: (1) produce and evaluate materials for space structures; (2) develop passive and active facilities for materials exposure and analysis in space; and (3) develop improved material systems for space structures. A major active facility for materials exposure is proposed to be mounted on the exterior truss of the Space Station Freedom (SSF). This Long Duration Space Materials Exposure (LDSE) experiment will be an approximately 6 1/2 ft. x 4 ft. panel facing into the velocity vector (RAM) to provide long term exposure (up to 30 years) to atomic oxygen, UV, micro meteorites, and other low earth orbit effects. It can expose large or small active (instrumented) or passive samples. These samples may be mounted in a removable Materials Flight Experiment (MFLEX) carrier which may be periodically brought into the SSF for examination by CMSS's other SSF facility, the Space Materials Evaluation Facility (SMEF), which will contain a Scanning Electron Microscope, a Variable Angle & Scanning Ellipsometer, a Fourier Transform Infrared Spectrometer, and other analysis equipment. These facilities will allow commercial firms to test their materials in space and promptly obtain information on their materials survivability in the LEO environment.
Aliganyira, Patrick; Kerber, Kate; Davy, Karen; Gamache, Nathalie; Sengendo, Namaala Hanifah; Bergh, Anne-Marie
2014-01-01
Introduction Prematurity is the leading cause of newborn death in Uganda, accounting for 38% of the nation's 39,000 annual newborn deaths. Kangaroo mother care is a high-impact; cost-effective intervention that has been prioritized in policy in Uganda but implementation has been limited. Methods A standardised, cross-sectional, mixed-method evaluation design was used, employing semi-structured key-informant interviews and observations in 11 health care facilities implementing kangaroo mother care in Uganda. Results The facilities visited scored between 8.28 and 21.72 out of the possible 30 points with a median score of 14.71. Two of the 3 highest scoring hospitals were private, not-for-profit hospitals whereas the second highest scoring hospital was a central teaching hospital. Facilities with KMC services are not equally distributed throughout the country. Only 4 regions (Central 1, Central 2, East-Central and Southwest) plus the City of Kampala were identified as having facilities providing KMC services. Conclusion KMC services are not instituted with consistent levels of quality and are often dependent on private partner support. With increasing attention globally and in country, Uganda is in a unique position to accelerate access to and quality of health services for small babies across the country. PMID:25667699
Aliganyira, Patrick; Kerber, Kate; Davy, Karen; Gamache, Nathalie; Sengendo, Namaala Hanifah; Bergh, Anne-Marie
2014-01-01
Prematurity is the leading cause of newborn death in Uganda, accounting for 38% of the nation's 39,000 annual newborn deaths. Kangaroo mother care is a high-impact; cost-effective intervention that has been prioritized in policy in Uganda but implementation has been limited. A standardised, cross-sectional, mixed-method evaluation design was used, employing semi-structured key-informant interviews and observations in 11 health care facilities implementing kangaroo mother care in Uganda. The facilities visited scored between 8.28 and 21.72 out of the possible 30 points with a median score of 14.71. Two of the 3 highest scoring hospitals were private, not-for-profit hospitals whereas the second highest scoring hospital was a central teaching hospital. Facilities with KMC services are not equally distributed throughout the country. Only 4 regions (Central 1, Central 2, East-Central and Southwest) plus the City of Kampala were identified as having facilities providing KMC services. KMC services are not instituted with consistent levels of quality and are often dependent on private partner support. With increasing attention globally and in country, Uganda is in a unique position to accelerate access to and quality of health services for small babies across the country.
Effective antibiotic stewardship in spinal cord injury: Challenges and a way forward.
Skelton, Felicia; Suda, Katie; Evans, Charlesnika; Trautner, Barbara
2018-01-11
Context Antibiotic stewardship, defined as a multidisciplinary program to reduce the misuse of antibiotics, and in turn, antibiotic resistance, is a high priority. Persons with spinal cord injury/disorder (SCI/D) are vulnerable to receiving multiple courses of antibiotics over their lifetime given frequent healthcare exposure, and have high rates of bacterial infection with multi-drug resistant organisms. Additional challenges to evaluating appropriate use of antibiotics in this population include bacterial colonization in the urine and the differences in the presenting signs and symptoms of infection. Therefore, Veterans Health Administration (VHA) facilities with SCI/D centers need effective antibiotic stewardship programs. Results We analyzed the results of a 2012 VHA-wide survey evaluating available antibiotic stewardship resources, and compared the resources present at facilities with SCI/D (n=23) versus non-SCI/D facilities (n=107). VHA facilities with SCI/D centers are more likely to have components of an antibiotic stewardship program that have led to reduced antibiotic use in previous studies. They are also more likely to have personnel with infectious diseases training. Conclusion VHA facilities with SCI/D centers have the resources needed for antibiotic stewardship. The next step will be to determine how to implement effective antibiotic stewardship tailored for this patient care setting.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-29
... DOE to carry out a high-level radioactive waste management demonstration project at the Western New... solidification of high-level radioactive waste for disposal in a Federal repository for permanent disposal. The... and other facilities where the solidified high-level radioactive waste was stored, the facilities used...
The report describes a case study that applies EPA/600/R-05/123a, the guidance for conducting air pathway analyses of landfill gas emissions that are of interest to superfund remedial project managers, on-scene coordinators, facility owners, and potentially responsible parties. T...
NASA Technical Reports Server (NTRS)
Duc, M. La; Chen, F.; Kern, R.; Koukol, R.; Baker, A.; Venkateswaran, K.
2001-01-01
A study in which several surface samples, retrieved from both the Mars Odyssey Spacecraft and the Kennedy Space Center (KSC) Spacecraft Assembly and Encapsulation Facility II (SAEF-II), were prcesed and evaluated by both molecular and traditional culture-based methods for the microbial diversity.
Outdoor Test Facility and Related Facilities | Photovoltaic Research | NREL
advanced or emerging photovoltaic (PV) technologies under simulated, accelerated indoor and outdoor, and evaluate prototype, pre-commercial, and commercial PV modules. One of the major roles of researchers at the OTF is to work with industry to develop uniform and consensus standards and codes for testing PV
Obtaining Life-Cycle Cost-Effective Facilities in the Department of Defense
2013-01-01
8 Step 3: Regional, Service- Level , and OSD Project Ranking...13 2.3. Actors and Barriers to Life-Cycle Cost-Effective Facilities in the Regional, Service- Level , and OSD Project Ranking...Congressional authorization and appropriation OMB evaluation Regional, service- level , and OSD project ranking Economic analysis and DD form 1391 completed