A survey of packages for large linear systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Kesheng; Milne, Brent
2000-02-11
This paper evaluates portable software packages for the iterative solution of very large sparse linear systems on parallel architectures. While we cannot hope to tell individual users which package will best suit their needs, we do hope that our systematic evaluation provides essential unbiased information about the packages and the evaluation process may serve as an example on how to evaluate these packages. The information contained here include feature comparisons, usability evaluations and performance characterizations. This review is primarily focused on self-contained packages that can be easily integrated into an existing program and are capable of computing solutions to verymore » large sparse linear systems of equations. More specifically, it concentrates on portable parallel linear system solution packages that provide iterative solution schemes and related preconditioning schemes because iterative methods are more frequently used than competing schemes such as direct methods. The eight packages evaluated are: Aztec, BlockSolve,ISIS++, LINSOL, P-SPARSLIB, PARASOL, PETSc, and PINEAPL. Among the eight portable parallel iterative linear system solvers reviewed, we recommend PETSc and Aztec for most application programmers because they have well designed user interface, extensive documentation and very responsive user support. Both PETSc and Aztec are written in the C language and are callable from Fortran. For those users interested in using Fortran 90, PARASOL is a good alternative. ISIS++is a good alternative for those who prefer the C++ language. Both PARASOL and ISIS++ are relatively new and are continuously evolving. Thus their user interface may change. In general, those packages written in Fortran 77 are more cumbersome to use because the user may need to directly deal with a number of arrays of varying sizes. Languages like C++ and Fortran 90 offer more convenient data encapsulation mechanisms which make it easier to implement a clean and intuitive user interface. In addition to reviewing these portable parallel iterative solver packages, we also provide a more cursory assessment of a range of related packages, from specialized parallel preconditioners to direct methods for sparse linear systems.« less
Mousavi Khaneghah, Amin; Hashemi, Seyed Mohammad Bagher; Eş, Ismail; Fracassetti, Daniela; Limbo, Sara
2018-07-01
Interest in the utilization of antimicrobial active packaging for food products has increased in recent years. Antimicrobial active packaging involves the incorporation of antimicrobial compounds into packaging materials, with the aim of maintaining or extending food quality and shelf life. Plant extracts, essential oils, organic acids, bacteriocins, inorganic substances, enzymes, and proteins are used as antimicrobial agents in active packaging. Evaluation of the antimicrobial activity of packaging materials using different methods has become a critical issue for both food safety and the commercial utilization of such packaging technology. This article reviews the different types of antimicrobial agents used for active food packaging materials, the main incorporation techniques, and the assessment methods used to examine the antimicrobial activity of packaging materials, taking into account their safety as food contact materials.
National Institute of Standards and Technology Data Gateway
NIST Scoring Package (PC database for purchase) The NIST Scoring Package (Special Database 1) is a reference implementation of the draft Standard Method for Evaluating the Performance of Systems Intended to Recognize Hand-printed Characters from Image Data Scanned from Forms.
An Evaluation of Automotive Interior Packages Based on Human Ocular and Joint Motor Properties
NASA Astrophysics Data System (ADS)
Tanaka, Yoshiyuki; Rakumatsu, Takeshi; Horiue, Masayoshi; Miyazaki, Tooru; Nishikawa, Kazuo; Nouzawa, Takahide; Tsuji, Toshio
This paper proposes a new evaluation method of an automotive interior package based on human oculomotor and joint-motor properties. Assuming the long-term driving situation in the express high way, the three evaluation indices were designed on i) the ratio of head motion at gazing the driving items; ii) the load torque for maintaining the standard driving posture; and iii) the human force manipulability at the end-point of human extremities. Experiments were carried out for two different interior packages with four subjects who have the special knowledge on the automobile development. Evaluation results demonstrate that the proposed method can quantitatively analyze the driving interior in good agreement with the generally accepted subjective opinion in the automobile industry.
Contamination in food from packaging material.
Lau, O W; Wong, S K
2000-06-16
Packaging has become an indispensible element in the food manufacturing process, and different types of additives, such as antioxidants, stabilizers, lubricants, anti-static and anti-blocking agents, have also been developed to improve the performance of polymeric packaging materials. Recently the packaging has been found to represent a source of contamination itself through the migration of substances from the packaging into food. Various analytical methods have been developed to analyze the migrants in the foodstuff, and migration evaluation procedures based on theoretical prediction of migration from plastic food contact material were also introduced recently. In this paper, the regulatory control, analytical methodology, factors affecting the migration and migration evaluation are reviewed.
Evaluation of standardized sample collection, packaging, and ...
Journal Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures.
49 CFR 173.415 - Authorized Type A packages.
Code of Federal Regulations, 2014 CFR
2014-10-01
... tests and an engineering evaluation or comparative data showing that the construction methods, packaging design, and materials of construction comply with that specification. After January 1, 2017 each offeror... meets the pertinent design and performance requirements for a DOT 7A Type A specification package. (2...
A review of evaluative studies of computer-based learning in nursing education.
Lewis, M J; Davies, R; Jenkins, D; Tait, M I
2001-01-01
Although there have been numerous attempts to evaluate the learning benefits of computer-based learning (CBL) packages in nursing education, the results obtained have been equivocal. A literature search conducted for this review found 25 reports of the evaluation of nursing CBL packages since 1966. Detailed analysis of the evaluation methods used in these reports revealed that most had significant design flaws, including the use of too small a sample group, the lack of a control group, etc. Because of this, the conclusions reached were not always valid. More effort is required in the design of future evaluation studies of nursing CBL packages. Copyright 2001 Harcourt Publishers Ltd.
NASA Electronic Parts and Packaging Program
NASA Technical Reports Server (NTRS)
Kayali, Sammy
2000-01-01
NEPP program objectives are to: (1) Access the reliability of newly available electronic parts and packaging technologies for usage on NASA projects through validations, assessments, and characterizations, and the development of test methods/tools; (2)Expedite infusion paths for advanced (emerging) electronic parts and packaging technologies by evaluations of readiness for manufacturability and project usage consideration; (3) Provide NASA projects with technology selection, application, and validation guidelines for electronic parts and packaging hardware and processes; nd (4) Retain and disseminate electronic parts and packaging quality assurance, reliability validations, tools, and availability information to the NASA community.
Şen, Ferhat; Uzunsoy, İrem; Baştürk, Emre; Kahraman, Memet Vezir
2017-08-15
This study aimed to develop polyelectrolyte structured antimicrobial food packaging materials that do not contain any antimicrobial agents. Cationic starch was synthesized and characterized by FT-IR spectroscopy and 1 H NMR spectroscopy. Its nitrogen content was determined by Kjeldahl method. Polyelectrolyte structured antimicrobial food packaging materials were prepared using starch, cationic starch and sodium alginate. Antimicrobial activity of materials was defined by inhibition zone method (disc diffusion method). Thermal stability of samples was evaluated by TGA and DSC. Hydrophobicity of samples was determined by contact angle measurements. Surface morphology of samples was investigated by SEM. Moreover, gel contents of samples were determined. The obtained results prove that produced food packaging materials have good thermal, antimicrobial and surface properties, and they can be used as food packaging material in many industries. Copyright © 2017 Elsevier Ltd. All rights reserved.
Microcomputer Programs for Educational Statistics: A Review of Popular Programs. TME Report 89.
ERIC Educational Resources Information Center
Stemmer, Paul M.; Berger, Carl F.
This publication acquaints the user with microcomputer statistical packages and offers a method for evaluation based on a set of criteria that can be adapted to the needs of the user. Several popular packages, typical of those available, are reviewed in detail: (1) Abstat, an easy to use command driven package compatible with the IBM PC or the…
Ackerman, L K; Noonan, G O; Begley, T H
2009-12-01
The ambient ionization technique direct analysis in real time (DART) was characterized and evaluated for the screening of food packaging for the presence of packaging additives using a benchtop mass spectrometer (MS). Approximate optimum conditions were determined for 13 common food-packaging additives, including plasticizers, anti-oxidants, colorants, grease-proofers, and ultraviolet light stabilizers. Method sensitivity and linearity were evaluated using solutions and characterized polymer samples. Additionally, the response of a model additive (di-ethyl-hexyl-phthalate) was examined across a range of sample positions, DART, and MS conditions (temperature, voltage and helium flow). Under optimal conditions, molecular ion (M+H+) was the major ion for most additives. Additive responses were highly sensitive to sample and DART source orientation, as well as to DART flow rates, temperatures, and MS inlet voltages, respectively. DART-MS response was neither consistently linear nor quantitative in this setting, and sensitivity varied by additive. All additives studied were rapidly identified in multiple food-packaging materials by DART-MS/MS, suggesting this technique can be used to screen food packaging rapidly. However, method sensitivity and quantitation requires further study and improvement.
Guillard, V; Mauricio-Iglesias, M; Gontard, N
2010-11-01
Classical stabilization techniques (thermal treatments) usually involve food to be packed after being processed. On the contrary and increasingly, novel food processing methods, such as high pressure or microwaves, imply that both packaging and foodstuff undergo the stabilization treatment. Moreover, novel treatments (UV light, irradiation, ozone, cold plasma) are specifically used for disinfection and sterilization of the packaging material itself. Therefore, in the last several years a number of papers have focused on the effects of these new treatments on food-packaging interactions with a special emphasis on chemical migration and safety concerns. New packaging materials merged on the market with specific interest regarding the environment (i.e. bio-sourced materials) or mechanical and barrier properties (i.e. nanocomposites packaging materials). It is time to evaluate the knowledge about how these in-package food technologies affect food/packaging interactions, and especially for novel biodegradable and/or active materials. This article presents the effect of high pressure treatment, microwave heating, irradiation, UV-light, ozone and, cold plasma treatment on food/packaging interactions.
DREAMTools: a Python package for scoring collaborative challenges
Cokelaer, Thomas; Bansal, Mukesh; Bare, Christopher; Bilal, Erhan; Bot, Brian M.; Chaibub Neto, Elias; Eduati, Federica; de la Fuente, Alberto; Gönen, Mehmet; Hill, Steven M.; Hoff, Bruce; Karr, Jonathan R.; Küffner, Robert; Menden, Michael P.; Meyer, Pablo; Norel, Raquel; Pratap, Abhishek; Prill, Robert J.; Weirauch, Matthew T.; Costello, James C.; Stolovitzky, Gustavo; Saez-Rodriguez, Julio
2016-01-01
DREAM challenges are community competitions designed to advance computational methods and address fundamental questions in system biology and translational medicine. Each challenge asks participants to develop and apply computational methods to either predict unobserved outcomes or to identify unknown model parameters given a set of training data. Computational methods are evaluated using an automated scoring metric, scores are posted to a public leaderboard, and methods are published to facilitate community discussions on how to build improved methods. By engaging participants from a wide range of science and engineering backgrounds, DREAM challenges can comparatively evaluate a wide range of statistical, machine learning, and biophysical methods. Here, we describe DREAMTools, a Python package for evaluating DREAM challenge scoring metrics. DREAMTools provides a command line interface that enables researchers to test new methods on past challenges, as well as a framework for scoring new challenges. As of March 2016, DREAMTools includes more than 80% of completed DREAM challenges. DREAMTools complements the data, metadata, and software tools available at the DREAM website http://dreamchallenges.org and on the Synapse platform at https://www.synapse.org. Availability: DREAMTools is a Python package. Releases and documentation are available at http://pypi.python.org/pypi/dreamtools. The source code is available at http://github.com/dreamtools/dreamtools. PMID:27134723
Calfee, M. Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall
2016-01-01
Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration. PMID:27362274
Calfee, M Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall
2016-12-01
Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration.
QFASAR: Quantitative fatty acid signature analysis with R
Bromaghin, Jeffrey F.
2017-01-01
Knowledge of predator diets provides essential insights into their ecology, yet diet estimation is challenging and remains an active area of research.Quantitative fatty acid signature analysis (QFASA) is a popular method of estimating diet composition that continues to be investigated and extended. However, software to implement QFASA has only recently become publicly available.I summarize a new R package, qfasar, for diet estimation using QFASA methods. The package also provides functionality to evaluate and potentially improve the performance of a library of prey signature data, compute goodness-of-fit diagnostics, and support simulation-based research. Several procedures in the package have not previously been published.qfasar makes traditional and recently published QFASA diet estimation methods accessible to ecologists for the first time. Use of the package is illustrated with signature data from Chukchi Sea polar bears and potential prey species.
Development and evaluation of an educational training package to promote health and wellbeing.
Gartshore, Emily; Briggs, Lydia; Blake, Holly
2017-11-23
supporting the health and wellbeing of healthcare employees is a national priority in the UK. to design, deliver and evaluate an educational package to promote health and wellbeing for nurses and midwives. an online training package was developed and administered in two ways: online (HAWN-online) or in a face-to-face workshop (HAWN-contact). A mixed methods evaluation was used to assess usability and acceptability of HAWN training. 316 nurses, midwives and students completed the online training package and 16 participants attended the workshop. HAWN-online significantly increased knowledge in core areas of workplace health and wellbeing. Nurses and midwives valued online and face-to-face delivery but found there were barriers to attendance at workshops. Participants advocated that training in workplace health should be mandatory for all frontline staff. employers should take steps to promote staff wellbeing through HAWN training, and address barriers to accessing workplace health training or supportive services.
Hori, Katsuhito; Yoshida, Naoko; Okumura, Tomonori; Okamura, Yasufumi; Kawakami, Junichi
2010-08-01
Orally disintegrating (OD) tablets are widely used in clinical practice. However, drug information on the choice and dispensing based on their stability after opening packages and usability in patients and dispensaries is not sufficient. The aim of this study was to investigate possible evaluation methods of the stability and usability of amlodipine OD tablets. Additives of the brand were changed in April 2009, and therefore the previous and current forms and two generics, current and newly marketed (in November 2009) products of different firms, were used. OD tablets were stored at 25 degrees C and 75% relative humidity for 3 months after opening the packages, and their physicochemical properties were evaluated. Their weight, diameter, thickness, and color difference increased slightly from the initial state. The extent of the change in their hardness, disintegration time, and friability was different among products. These physicochemical changes were acceptable in dispensary practice. Storage after opening the packages did not affect their dissolution rate. The dissolution rate at the initial state of the current brand was slower than that of the previous one. All products used were able to be dispensed by an automatic tablet-packing machine and applied to the so-called simple suspension method for intubational administration. Sensory evaluation tests revealed no major difference in the oral disintegration time, taste, impression, and preference among products. In conclusion, the stability and usability of amlodipine OD tablets used in this study were examined using several methods, and they can be used equivalently from the stability and usability viewpoints.
Quantitative evaluation of software packages for single-molecule localization microscopy.
Sage, Daniel; Kirshner, Hagai; Pengo, Thomas; Stuurman, Nico; Min, Junhong; Manley, Suliana; Unser, Michael
2015-08-01
The quality of super-resolution images obtained by single-molecule localization microscopy (SMLM) depends largely on the software used to detect and accurately localize point sources. In this work, we focus on the computational aspects of super-resolution microscopy and present a comprehensive evaluation of localization software packages. Our philosophy is to evaluate each package as a whole, thus maintaining the integrity of the software. We prepared synthetic data that represent three-dimensional structures modeled after biological components, taking excitation parameters, noise sources, point-spread functions and pixelation into account. We then asked developers to run their software on our data; most responded favorably, allowing us to present a broad picture of the methods available. We evaluated their results using quantitative and user-interpretable criteria: detection rate, accuracy, quality of image reconstruction, resolution, software usability and computational resources. These metrics reflect the various tradeoffs of SMLM software packages and help users to choose the software that fits their needs.
Xu, H D; Zhao, L; Tang, S C; Zhang, J; Kong, F L; Jia, G
2016-12-20
Objective: To explore and validate suitable risk assessment methods for titanium dioxide though applying three risk assessment tools for nanomaterials based on the control banding (CB) approach. Methods: A factory manufacturing titanium dioxide in Jinan city, Shandong province, was assessed using a quantitative exposure method and qualitative risk assessment methods in September, 2014. A condensation particle counter equipment was used to monitor the number concentration of particles at packaging workshop and jet milling workshop. We employed three control banding tools, including CB nanotool, Stoffenmanager nano and the Guidance on working safely with nanomaterials and nanoproducts (GWSNN) to evaluate the two workshops, then compared the evaluation results. Results: The increases of particle concentrations were generated directly by packaging and jet milling processes, the number concentration from (3.52±1.46) ×10(4)/cm(3) to (14.70±8.86) ×10(4)/cm(3) at packaging workshop and from (0.97±0.25) ×10(4)/cm(3) to (1.26±0.35) ×10(4)/cm(3) at milling workshop (both P <0.05) . The number concentrations at packaging workshop were higher than those at jet milling workshop during both manufacturing and break times (both P <0.05) . The results of CB nanotool showed that the risk level of the packaging workshop was classified as high and the risk level of the jet milling workshop was classified asmedium. The results of Stoffenmanager nano showed that the risk level of the packaging workshop was classified as medium and the risk level of the jet milling workshop was classified as low. The results of GWSNN showed that the risk level of packaging workshop was classified as high and the risk level of jet milling workshop was classified as low. Conclusion: The results of evaluation based on the three control banding tools are related and aligned with the results of quantitative monitoring, so they are all suitable to perform occupational health risk assessment on industrial scale production of titanium dioxideto some extent.
Prediction of drug-packaging interactions via molecular dynamics (MD) simulations.
Feenstra, Peter; Brunsteiner, Michael; Khinast, Johannes
2012-07-15
The interaction between packaging materials and drug products is an important issue for the pharmaceutical industry, since during manufacturing, processing and storage a drug product is continuously exposed to various packaging materials. The experimental investigation of a great variety of different packaging material-drug product combinations in terms of efficacy and safety can be a costly and time-consuming task. In our work we used molecular dynamics (MD) simulations in order to evaluate the applicability of such methods to pre-screening of the packaging material-solute compatibility. The solvation free energy and the free energy of adsorption of diverse solute/solvent/solid systems were estimated. The results of our simulations agree with experimental values previously published in the literature, which indicates that the methods in question can be used to semi-quantitatively reproduce the solid-liquid interactions of the investigated systems. Copyright © 2012 Elsevier B.V. All rights reserved.
Bellot, Pau; Olsen, Catharina; Salembier, Philippe; Oliveras-Vergés, Albert; Meyer, Patrick E
2015-09-29
In the last decade, a great number of methods for reconstructing gene regulatory networks from expression data have been proposed. However, very few tools and datasets allow to evaluate accurately and reproducibly those methods. Hence, we propose here a new tool, able to perform a systematic, yet fully reproducible, evaluation of transcriptional network inference methods. Our open-source and freely available Bioconductor package aggregates a large set of tools to assess the robustness of network inference algorithms against different simulators, topologies, sample sizes and noise intensities. The benchmarking framework that uses various datasets highlights the specialization of some methods toward network types and data. As a result, it is possible to identify the techniques that have broad overall performances.
A portable thoracic closed drainage instrument for hemopneumothorax.
Tang, Hua; Pan, Tiewen; Qin, Xiong; Xue, Lei; Wu, Bin; Zhao, Xuewei; Sun, Guangyuan; Yuan, Xinyu; Xu, Zhifei
2012-03-01
Hemopneumothorax is a common sequelae of traumatic thoracic injury. The most effective treatment of this condition is thoracic drainage. Despite the common occurrence of this condition, available instruments are difficult to use emergently, particularly when large amounts of patients need to be drained. In the present experiment, a newly designed chest tube and thoracic closed drainage package is described and preliminarily evaluated with the goal to improve the treatment of traumatic hemopneumothorax. Twenty canines were divided into two groups. In one group, the newly designed thoracic closed drainage package was used, whereas in the other group a currently available chest tube and bottle were used. Drainage test, ultrasound examination, flushing test, and tension test were performed to evaluate the effectiveness of the drainage package. We found that the newly-designed drainage tube is as effective as the common tube when evaluated using all of the chosen methods. In addition, the package is very lightweight and portable. The newly-designed thoracic drainage package is very effective in the emergency treatment of thoracic trauma and may be more suitable for the emergency treatment of hemopneumothorax.
Piaskowska, N.; Daszkiewicz, T.; Kubiak, D.; Zapotoczny, P.
2016-01-01
This study evaluated the effect of vacuum and modified atmosphere (40% CO2+60% N2, MA) packaging on the chemical composition, physicochemical properties and sensory attributes of chill-stored meat from 10 fallow deer (Dama dama) bucks at 17 to 18 months of age. The animals were hunter-harvested in the forests of north-eastern Poland. During carcass dressing (48 to 54 h post mortem), both musculus longissimus muscles were cut out. Each muscle was divided into seven sections which were allocated to three groups: 0, A, and B. Samples 0 were immediately subjected to laboratory analyses. Samples A were vacuum-packaged, and samples B were packaged in MA. Packaged samples were stored for 7, 14, and 21 days at 2°C. The results of the present study showed that the evaluated packaging systems had no significant effect on the quality of fallow deer meat during chilled storage. However, vacuum-packaged meat samples were characterised by greater drip loss. Vacuum and MA packaging contributed to preserving the desired physicochemical properties and sensory attributes of meat during 21 days of storage. Regardless of the packaging method used, undesirable changes in the colour, water-holding capacity and juiciness of meat, accompanied by tenderness improvement, were observed during chilled storage. PMID:27165026
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abramczyk, Glenn; Hensel, Stephen J; Gupta, Narendra K.
Title 10 of the United States Code of Federal Regulations Part 71 for the Nuclear Regulatory Commission (10 CFR Part 71.73) requires that Type B radioactive material (RAM) packages satisfy certain Hypothetical Accident Conditions (HAC) thermal design requirements to ensure package safety during accidental fire conditions. Compliance with thermal design requirements can be met by prototype tests, analyses only or a combination of tests and analyses. Normally, it is impractical to meet all the HAC using tests only and the analytical methods are too complex due to the multi-physics non-linear nature of the fire event. Therefore, a combination of testsmore » and thermal analyses methods using commercial heat transfer software are used to meet the necessary design requirements. The authors, along with his other colleagues at Savannah River National Laboratory in Aiken, SC, USA, have successfully used this 'tests and analyses' approach in the design and certification of several United States' DOE/NNSA certified packages, e.g. 9975, 9977, 9978, 9979, H1700, and Bulk Tritium Shipping Package (BTSP). This paper will describe these methods and it is hoped that the RAM Type B package designers and analysts can use them for their applications.« less
Nondestructive determination of activity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chabalier, B.
1996-08-01
Characterization and appraisal tests include the measurement of activity in raw waste and waste packages. After conditioning, variations in density, matrix composition, and geometry make evaluation of the radionuclide activity in a package destined for storage nearly impossible without measurements and with a low uncertainty. Various nondestructive measuring techniques that use ionizing radiation are employed to characterize waste packages and raw waste. Gamma spectrometry is the most widely used technique because of its simple operation and low cost. This technique is used to quantify the beta-gamma and alpha activity of gamma-emitting radionuclides as well as to check the radioactive homogeneitymore » of the waste packages. Numerous systems for directly measuring waste packages have been developed. Two types of methods may be distinguished, depending on whether results that come from the measurements are weighted by an experimentally determined corrective term or by calculation. Through the MARCO and CARACO measuring systems, a method is described that allows one to quantify the activity of the beta-gamma and alpha radionuclides contained in either a waste package or raw waste whose geometries and material compositions are more or less accurately known. This method is based on (a) measurement by gamma spectrometry of the beta-gamma and alpha activity of the gamma-emitting radionuclides contained in the waste package and (b) the application of calculated corrections; thus, the limitations imposed by reference package geometry and matrix are avoided.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stover, Tracy E.; Baker, James S.; Ratliff, Michael D.
The classic Limiting Surface Density (LSD) method is an empirical calculation technique for analyzing and setting mass limits for fissile items in storage arrays. LSD is a desirable method because it can reduce or eliminate the need for lengthy detailed Monte Carlo models of storage arrays. The original (or classic) method was developed based on idealized arrays of bare spherical metal items in air-spaced cubic units in a water-reflected cubic array. In this case, the geometric and material-based surface densities were acceptably correlated by linear functions. Later updates to the method were made to allow for concrete reflection rather thanmore » water, cylindrical masses rather than spheres, different material forms, and noncubic arrays. However, in the intervening four decades since those updates, little work has been done to update the method, especially for use with contemporary highly heterogeneous shipping packages that are noncubic and stored in noncubic arrays. In this work, the LSD method is reevaluated for application to highly heterogeneous shipping packages for fissile material. The package modeled is the 9975 shipping package, currently the primary package used to store fissile material at Savannah River Site’s K-Area Complex. The package is neither cubic nor rectangular but resembles nested cylinders of stainless steel, lead, aluminum, and Celotex. The fissile content is assumed to be a cylinder of plutonium metal. The packages may be arranged in arrays with both an equal number of packages per side (package cubic) and an unequal number of packages per side (noncubic). The cubic arrangements are used to derive the 9975-specific material and geometry constants for the classic linear form LSD method. The linear form of the LSD, with noncubic array adjustment, is applied and evaluated against computational models for these packages to determine the critical unit fissile mass. Sensitivity equations are derived from the classic method, and these are also used to make projections of the critical unit fissile mass. It was discovered that the heterogeneous packages have a nonlinear surface density versus critical mass relationship compared to the acceptably linear response of bare spherical fissile masses. Methodology is developed to address the nonlinear response. In so doing, the solution to the nonlinear LSD method becomes decoupled from the critical mass of a single unit, adding to its flexibility. The ability of the method to predict changes in neutron multiplication due to perturbations in a parameter is examined to provide a basis for analyzing upset conditions. In conclusion, a full rederivation of the classic LSD method from diffusion theory is also included as this was found to be lacking in the available literature.« less
Stover, Tracy E.; Baker, James S.; Ratliff, Michael D.; ...
2018-03-02
The classic Limiting Surface Density (LSD) method is an empirical calculation technique for analyzing and setting mass limits for fissile items in storage arrays. LSD is a desirable method because it can reduce or eliminate the need for lengthy detailed Monte Carlo models of storage arrays. The original (or classic) method was developed based on idealized arrays of bare spherical metal items in air-spaced cubic units in a water-reflected cubic array. In this case, the geometric and material-based surface densities were acceptably correlated by linear functions. Later updates to the method were made to allow for concrete reflection rather thanmore » water, cylindrical masses rather than spheres, different material forms, and noncubic arrays. However, in the intervening four decades since those updates, little work has been done to update the method, especially for use with contemporary highly heterogeneous shipping packages that are noncubic and stored in noncubic arrays. In this work, the LSD method is reevaluated for application to highly heterogeneous shipping packages for fissile material. The package modeled is the 9975 shipping package, currently the primary package used to store fissile material at Savannah River Site’s K-Area Complex. The package is neither cubic nor rectangular but resembles nested cylinders of stainless steel, lead, aluminum, and Celotex. The fissile content is assumed to be a cylinder of plutonium metal. The packages may be arranged in arrays with both an equal number of packages per side (package cubic) and an unequal number of packages per side (noncubic). The cubic arrangements are used to derive the 9975-specific material and geometry constants for the classic linear form LSD method. The linear form of the LSD, with noncubic array adjustment, is applied and evaluated against computational models for these packages to determine the critical unit fissile mass. Sensitivity equations are derived from the classic method, and these are also used to make projections of the critical unit fissile mass. It was discovered that the heterogeneous packages have a nonlinear surface density versus critical mass relationship compared to the acceptably linear response of bare spherical fissile masses. Methodology is developed to address the nonlinear response. In so doing, the solution to the nonlinear LSD method becomes decoupled from the critical mass of a single unit, adding to its flexibility. The ability of the method to predict changes in neutron multiplication due to perturbations in a parameter is examined to provide a basis for analyzing upset conditions. In conclusion, a full rederivation of the classic LSD method from diffusion theory is also included as this was found to be lacking in the available literature.« less
Deal or No Deal? Evaluating Big Deals and Their Journals
ERIC Educational Resources Information Center
Blecic, Deborah D.; Wiberley, Stephen E., Jr.; Fiscella, Joan B.; Bahnmaier-Blaszczak, Sara; Lowery, Rebecca
2013-01-01
This paper presents methods to develop metrics that compare Big Deal journal packages and the journals within those packages. Deal-level metrics guide selection of a Big Deal for termination. Journal-level metrics guide selection of individual subscriptions from journals previously provided by a terminated deal. The paper argues that, while the…
An Examination of the Addition of Video Informed Reflective Practice to the Active Support Toolkit
ERIC Educational Resources Information Center
Baker, Peter; Appleton, Philippa; Williams, Rosie
2017-01-01
Background: This study evaluated a package of Active Support (AS), which included standard training with additional video informed reflective practice. Materials & Methods: The training package was implemented as part of a service improvement initiative in four residential intellectual disability homes, using a concurrent multiple baseline…
MULTIVARIATERESIDUES : A Mathematica package for computing multivariate residues
NASA Astrophysics Data System (ADS)
Larsen, Kasper J.; Rietkerk, Robbert
2018-01-01
Multivariate residues appear in many different contexts in theoretical physics and algebraic geometry. In theoretical physics, they for example give the proper definition of generalized-unitarity cuts, and they play a central role in the Grassmannian formulation of the S-matrix by Arkani-Hamed et al. In realistic cases their evaluation can be non-trivial. In this paper we provide a Mathematica package for efficient evaluation of multivariate residues based on methods from computational algebraic geometry.
Moudache, M; Nerín, C; Colon, M; Zaidi, F
2017-08-15
An antioxidant food packaging material was developed and applied to fresh minced pork meat. The material consists of a multilayer polyethylene film in which 4 different concentrations (2%, 5%, 10%, and 15%) of olive leaves (OL) extract were immobilized in an adhesive formula used to build the multilayer. The antioxidants were not in direct contact with the meat. The packaged meat was kept at 4°C during 16days and finally analyzed by two methods: Raman spectroscopy and thiobarbituric acid reactive substances (TBARS). Raman demonstrated a higher sensitivity for antioxidant evaluation than TBARS. Color of fresh meat packaged with the active film was also measured to evaluate the shelf life of packaged meat. The results showed that active film containing natural antioxidants efficiently enhanced the stability of fresh meat against oxidation processes, thus being a promising way to extend the shelf life of fresh minced meat for about two days. Copyright © 2017. Published by Elsevier Ltd.
Validation of thermal effects of LED package by using Elmer finite element simulation method
NASA Astrophysics Data System (ADS)
Leng, Lai Siang; Retnasamy, Vithyacharan; Mohamad Shahimin, Mukhzeer; Sauli, Zaliman; Taniselass, Steven; Bin Ab Aziz, Muhamad Hafiz; Vairavan, Rajendaran; Kirtsaeng, Supap
2017-02-01
The overall performance of the Light-emitting diode, LED package is critically affected by the heat attribution. In this study, open source software - Elmer FEM has been utilized to study the thermal analysis of the LED package. In order to perform a complete simulation study, both Salome software and ParaView software were introduced as Pre and Postprocessor. The thermal effect of the LED package was evaluated by this software. The result has been validated with commercially licensed software based on previous work. The percentage difference from both simulation results is less than 5% which is tolerable and comparable.
NASA Astrophysics Data System (ADS)
Chen, Shuming; Wang, Dengfeng; Liu, Bo
This paper investigates optimization design of the thickness of the sound package performed on a passenger automobile. The major characteristics indexes for performance selected to evaluate the processes are the SPL of the exterior noise and the weight of the sound package, and the corresponding parameters of the sound package are the thickness of the glass wool with aluminum foil for the first layer, the thickness of the glass fiber for the second layer, and the thickness of the PE foam for the third layer. In this paper, the process is fundamentally with multiple performances, thus, the grey relational analysis that utilizes grey relational grade as performance index is especially employed to determine the optimal combination of the thickness of the different layers for the designed sound package. Additionally, in order to evaluate the weighting values corresponding to various performance characteristics, the principal component analysis is used to show their relative importance properly and objectively. The results of the confirmation experiments uncover that grey relational analysis coupled with principal analysis methods can successfully be applied to find the optimal combination of the thickness for each layer of the sound package material. Therefore, the presented method can be an effective tool to improve the vehicle exterior noise and lower the weight of the sound package. In addition, it will also be helpful for other applications in the automotive industry, such as the First Automobile Works in China, Changan Automobile in China, etc.
Deficiencies of product labeling directions for the preparation of radiopharmaceuticals.
Hung, Joseph C; Ponto, James A; Gadient, Katie R; Frie, Julia A; Aksamit, Carolyn M; Enquist, Cassandra L; Carrels, Katie E
2004-01-01
To identify potential deficiencies in product labeling (package insert) instructions for the preparation of radiopharmaceuticals. Preparation instructions, which include both reconstitution and quality control (QC) directions, as stated in the package inserts were evaluated for all commercially available reconstituted radiopharmaceuticals. Reviews of the package inserts were initially performed by each author, and then all identified deficiencies were compiled and evaluated by all authors. The preparation scenario for each package insert evaluated was based on a centralized nuclear pharmacy operation assuming typical support personnel, standard operating equipment, and workload. The instructions as stated in each package insert for the preparation (including QC) were rated as inadequate if a satisfactory preparation could not be prepared by a nuclear pharmacist or physician when instructions were followed exactly. Identified deficiencies in package insert instructions for the preparation of radiopharmaceuticals fell into the following five categories: (1) absent or incomplete directions (especially with regard to QC procedures); (2) restrictive directions (e.g., specific requirement to use designated needles, chromatography solvents, counting devices), (3) inconsistent directions (e.g., different reconstituted volumes for the same final drug product, unworkable expiration times); (4) impractical directions (e.g., unrealistically low reconstituted activity limits, dangerously high number of radiolabeled particles); and (5) vague directions (e.g., use of the words "should," "may," "recommend"). Manufacturers' directions for the preparation of radiopharmaceuticals often contain deficiencies and should be viewed as standard guidance rather than as requirements. Just as physicians are permitted to use U.S. Food and Drug Administration (FDA)-approved drugs for off-label indications, nuclear pharmacists should be allowed to use alternative methods for preparing radiopharmaceuticals, provided those methods have been validated to be as good as the stated directions and that the nuclear pharmacists do not engage in activities that fall outside the normal practice of pharmacy. Manufacturers, FDA, nuclear pharmacists, and nuclear physicians should work together to address identified deficiencies in package insert directions.
Torres, A; Guerra, M
1996-03-01
Color loss of a dietetic formulae based on pumpkin (Cucurbita maxima), rice, hen and vegetable oils was evaluated. The product was under an accelerated test at temperatures of 40, 50 and 70 degrees C for a month. The kinetic reaction of color loss (quality loss indicator) was obtained with n = 1 and Ea = 11.5 Kcal/mol. The product was also stored for sixth months at temperatures of 25, 30, 35 and 40 degrees C using glass containers, laminated and composite cans (non metallic). The color was measured by a colorimetric method and by sensory evaluation under the defined conditions of time, temperature and package. The statistical analyses of the color loss measured by instrument was performed by a randomized block design with a significance level of p < 0.05. The results obtained both by the instrument and by the sensory evaluation method, showed that the temperature and storage time has significant effect (p < 0.05) on the other hand, the package does not have a significant effect. It was concluded from this study that the product could be stored for 6 months at temperatures below 35 degrees C without changes in color.
Pediconi, Federica; Catalano, Carlo; Venditti, Fiammetta; Ercolani, Mauro; Carotenuto, Luigi; Padula, Simona; Moriconi, Enrica; Roselli, Antonella; Giacomelli, Laura; Kirchin, Miles A; Passariello, Roberto
2005-07-01
The objective of this study was to evaluate the value of a color-coded automated signal intensity curve software package for contrast-enhanced magnetic resonance mammography (CE-MRM) in patients with suspected breast cancer. Thirty-six women with suspected breast cancer based on mammographic and sonographic examinations were preoperatively evaluated on CE-MRM. CE-MRM was performed on a 1.5-T magnet using a 2D Flash dynamic T1-weighted sequence. A dosage of 0.1 mmol/kg of Gd-BOPTA was administered at a flow rate of 2 mL/s followed by 10 mL of saline. Images were analyzed with the new software package and separately with a standard display method. Statistical comparison was performed of the confidence for lesion detection and characterization with the 2 methods and of the diagnostic accuracy for characterization compared with histopathologic findings. At pathology, 54 malignant lesions and 14 benign lesions were evaluated. All 68 (100%) lesions were detected with both methods and good correlation with histopathologic specimens was obtained. Confidence for both detection and characterization was significantly (P < or = 0.025) better with the color-coded method, although no difference (P > 0.05) between the methods was noted in terms of the sensitivity, specificity, and overall accuracy for lesion characterization. Excellent agreement between the 2 methods was noted for both the determination of lesion size (kappa = 0.77) and determination of SI/T curves (kappa = 0.85). The novel color-coded signal intensity curve software allows lesions to be visualized as false color maps that correspond to conventional signal intensity time curves. Detection and characterization of breast lesions with this method is quick and easily interpretable.
Dogan, Canan Ekinci; Sancı, Rukiye
2015-01-01
Migration of formaldehyde to aqueous extracts from paper and cardboard food packaging materials was determined by an ultraviolet visible-spectrophotometric method at 410 nm. Intraday and interday precision of the method, expressed as coefficient of variation, varied between 1.5 to 4.4% and 7 to 8.8%, respectively. The limit of quantification was 0.28 mg kg(-1) for formaldehyde in aqueous extracts. The recovery of the method was over 90% for two different concentration levels in aqueous extracts. The method was applied to the migration of formaldehyde to aqueous extracts from 31 different paper and cardboard materials collected from the packaging sector, intended for food contact, such as tea filters, hot water filters, paper pouches and folding boxes. The results were between limit of detection 0.23 mg/kg and 40 mg kg(-1) and were evaluated according to the relevant directives.
ERIC Educational Resources Information Center
Thomson, Kendra M.; Martin, Garry L.; Fazzio, Daniela; Salem, Sandra; Young, Kristen; Yu, C. T.
2012-01-01
A widely used method for teaching children with autism is applied behavior analysis (ABA), and a main component of ABA programming is discrete-trials teaching (DTT). Using a modified multiple-baseline design across participants, we assessed the effectiveness of a DTT self-instructional package (Fazzio & Martin, 2007) for teaching four pairs of…
High resolution X-ray CT for advanced electronics packaging
NASA Astrophysics Data System (ADS)
Oppermann, M.; Zerna, T.
2017-02-01
Advanced electronics packaging is a challenge for non-destructive Testing (NDT). More, smaller and mostly hidden interconnects dominate modern electronics components and systems. To solve the demands of customers to get products with a high functionality by low volume, weight and price (e.g. mobile phones, personal medical monitoring systems) often the designers use System-in-Package solutions (SiP). The non-destructive testing of such devices is a big challenge. So our paper will impart fundamentals and applications for non-destructive evaluation of inner structures of electronics packaging for quality assurance and reliability investigations with a focus on X-ray methods, especially on high resolution X-ray computed tomography (CT).
Rasmussen, Mats; Damgaard, Rasmus; Buus, Peter; Guazzo, Dana Morton
2013-01-01
This Part 3 of this three-part research series reports the impact of high-voltage leak detection (HVLD) exposure on the physico-chemical stability of the packaged product. The product, intended for human administration by injection, is an aqueous solution formulation of the rapid acting insulin analogue, insulin aspart (NovoRapid®/NovoLog®) by Novo Nordisk A/S, Bagsværd, Denmark. The package is a small-volume form-fill-seal plastic laminate bag. Product-packages exposed to HVLD were compared to unexposed product after storage for 9 months at recommended storage conditions of 5 ± 3 °C. No differences in active ingredient or degradation products assays were noted. No changes in any other stability indicating parameter results were observed. This report concludes this three-part series. Part 1 documented HVLD method development and validation work. Part 2 explored the impact of various package material, package temperature, and package storage conditions on HVLD test results. Detection of leaks in the bag seal area was investigated. In conclusion, HVLD is reported to be a validatable leak test method suitable for rapid, nondestructive container-closure integrity evaluation of the subject product-package. In Part 1 of this three-part series, a leak test method based on electrical conductivity and capacitance, also called high-voltage leak detection (HVLD), was proven to find hole leaks in small plastic bags filled with a solution of insulin aspart intended for human injection (NovoRapid®/NovoLog® by Novo Nordisk A/S, Bagsværd, Denmark). In Part 2, the ability of the HVLD method to find other types of package leaks was tested, and the impact of package material and product storage temperature on HVLD results was explored. This final Part 3 checked how well the packaged protein drug solution maintained its potency after HVLD exposure over 9 months of storage under long-term stability conditions. Results showed that HVLD caused no harm to the product.
Adams, Jean V.; Slaght, Karen; Boogaard, Michael A.
2016-01-01
The authors developed a package, LW1949, for use with the statistical software R to automatically carry out the manual steps of Litchfield and Wilcoxon's method of evaluating dose–effect experiments. The LW1949 package consistently finds the best fitting dose–effect relation by minimizing the chi-squared statistic of the observed and expected number of affected individuals and substantially speeds up the line-fitting process and other calculations that Litchfield and Wilcoxon originally carried out by hand. Environ Toxicol Chem 2016;9999:1–4. Published 2016 Wiley Periodicals Inc. on behalf of SETAC. This article is a US Government work and, as such, is in the public domain in the United States of America.
XDesign: an open-source software package for designing X-ray imaging phantoms and experiments.
Ching, Daniel J; Gürsoy, Dogˇa
2017-03-01
The development of new methods or utilization of current X-ray computed tomography methods is impeded by the substantial amount of expertise required to design an X-ray computed tomography experiment from beginning to end. In an attempt to make material models, data acquisition schemes and reconstruction algorithms more accessible to researchers lacking expertise in some of these areas, a software package is described here which can generate complex simulated phantoms and quantitatively evaluate new or existing data acquisition schemes and image reconstruction algorithms for targeted applications.
XDesign: An open-source software package for designing X-ray imaging phantoms and experiments
Ching, Daniel J.; Gursoy, Dogˇa
2017-02-21
Here, the development of new methods or utilization of current X-ray computed tomography methods is impeded by the substantial amount of expertise required to design an X-ray computed tomography experiment from beginning to end. In an attempt to make material models, data acquisition schemes and reconstruction algorithms more accessible to researchers lacking expertise in some of these areas, a software package is described here which can generate complex simulated phantoms and quantitatively evaluate new or existing data acquisition schemes and image reconstruction algorithms for targeted applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W.; Keates, Steven
This protocol is intended to describe the recommended method when evaluating the whole-building performance of new construction projects in the commercial sector. The protocol focuses on energy conservation measures (ECMs) or packages of measures where evaluators can analyze impacts using building simulation. These ECMs typically require the use of calibrated building simulations under Option D of the International Performance Measurement and Verification Protocol (IPMVP).
Jo, Catherine L.; Ambs, Anita; Dresler, Carolyn M.; Backinger, Cathy L.
2017-01-01
Objective We aimed to investigate the effects of special packaging (child-resistant, adult-friendly) and tamper-resistant packaging on health and behavioral outcomes in order to identify research gaps and implications for packaging standards for tobacco products. Methods We searched seven databases for keywords related to special and tamper-resistant packaging, consulted experts, and reviewed citations of potentially relevant studies. 733 unique papers were identified. Two coders independently screened each title and abstract for eligibility. They then reviewed the full text of the remaining papers for a second round of eligibility screening. Included studies investigated a causal relationship between type of packaging or packaging regulation and behavioral or health outcomes and had a study population composed of consumers. Studies were excluded on the basis of publication type, if they were not peer-reviewed, and if they had low external validity. Two reviewers independently coded each paper for study and methodological characteristics and limitations. Discrepancies were discussed and resolved. Results The review included eight studies: four assessing people’s ability to access the contents of different packaging types and four evaluating the impact of packaging requirements on health-related outcomes. Child-resistant packaging was generally more difficult to open than non-child-resistant packaging. Child-resistant packaging requirements have been associated with reductions in child mortality. Conclusions Child-resistant packaging holds the expectation to reduce tobacco product poisonings among children under six. PMID:27939602
TCC: an R package for comparing tag count data with robust normalization strategies
2013-01-01
Background Differential expression analysis based on “next-generation” sequencing technologies is a fundamental means of studying RNA expression. We recently developed a multi-step normalization method (called TbT) for two-group RNA-seq data with replicates and demonstrated that the statistical methods available in four R packages (edgeR, DESeq, baySeq, and NBPSeq) together with TbT can produce a well-ranked gene list in which true differentially expressed genes (DEGs) are top-ranked and non-DEGs are bottom ranked. However, the advantages of the current TbT method come at the cost of a huge computation time. Moreover, the R packages did not have normalization methods based on such a multi-step strategy. Results TCC (an acronym for Tag Count Comparison) is an R package that provides a series of functions for differential expression analysis of tag count data. The package incorporates multi-step normalization methods, whose strategy is to remove potential DEGs before performing the data normalization. The normalization function based on this DEG elimination strategy (DEGES) includes (i) the original TbT method based on DEGES for two-group data with or without replicates, (ii) much faster methods for two-group data with or without replicates, and (iii) methods for multi-group comparison. TCC provides a simple unified interface to perform such analyses with combinations of functions provided by edgeR, DESeq, and baySeq. Additionally, a function for generating simulation data under various conditions and alternative DEGES procedures consisting of functions in the existing packages are provided. Bioinformatics scientists can use TCC to evaluate their methods, and biologists familiar with other R packages can easily learn what is done in TCC. Conclusion DEGES in TCC is essential for accurate normalization of tag count data, especially when up- and down-regulated DEGs in one of the samples are extremely biased in their number. TCC is useful for analyzing tag count data in various scenarios ranging from unbiased to extremely biased differential expression. TCC is available at http://www.iu.a.u-tokyo.ac.jp/~kadota/TCC/ and will appear in Bioconductor (http://bioconductor.org/) from ver. 2.13. PMID:23837715
Pouillot, Régis; Delignette-Muller, Marie Laure
2010-09-01
Quantitative risk assessment has emerged as a valuable tool to enhance the scientific basis of regulatory decisions in the food safety domain. This article introduces the use of two new computing resources (R packages) specifically developed to help risk assessors in their projects. The first package, "fitdistrplus", gathers tools for choosing and fitting a parametric univariate distribution to a given dataset. The data may be continuous or discrete. Continuous data may be right-, left- or interval-censored as is frequently obtained with analytical methods, with the possibility of various censoring thresholds within the dataset. Bootstrap procedures then allow the assessor to evaluate and model the uncertainty around the parameters and to transfer this information into a quantitative risk assessment model. The second package, "mc2d", helps to build and study two dimensional (or second-order) Monte-Carlo simulations in which the estimation of variability and uncertainty in the risk estimates is separated. This package easily allows the transfer of separated variability and uncertainty along a chain of conditional mathematical and probabilistic models. The usefulness of these packages is illustrated through a risk assessment of hemolytic and uremic syndrome in children linked to the presence of Escherichia coli O157:H7 in ground beef. These R packages are freely available at the Comprehensive R Archive Network (cran.r-project.org). Copyright 2010 Elsevier B.V. All rights reserved.
PAREMD: A parallel program for the evaluation of momentum space properties of atoms and molecules
NASA Astrophysics Data System (ADS)
Meena, Deep Raj; Gadre, Shridhar R.; Balanarayan, P.
2018-03-01
The present work describes a code for evaluating the electron momentum density (EMD), its moments and the associated Shannon information entropy for a multi-electron molecular system. The code works specifically for electronic wave functions obtained from traditional electronic structure packages such as GAMESS and GAUSSIAN. For the momentum space orbitals, the general expression for Gaussian basis sets in position space is analytically Fourier transformed to momentum space Gaussian basis functions. The molecular orbital coefficients of the wave function are taken as an input from the output file of the electronic structure calculation. The analytic expressions of EMD are evaluated over a fine grid and the accuracy of the code is verified by a normalization check and a numerical kinetic energy evaluation which is compared with the analytic kinetic energy given by the electronic structure package. Apart from electron momentum density, electron density in position space has also been integrated into this package. The program is written in C++ and is executed through a Shell script. It is also tuned for multicore machines with shared memory through OpenMP. The program has been tested for a variety of molecules and correlated methods such as CISD, Møller-Plesset second order (MP2) theory and density functional methods. For correlated methods, the PAREMD program uses natural spin orbitals as an input. The program has been benchmarked for a variety of Gaussian basis sets for different molecules showing a linear speedup on a parallel architecture.
Determinant Computation on the GPU using the Condensation Method
NASA Astrophysics Data System (ADS)
Anisul Haque, Sardar; Moreno Maza, Marc
2012-02-01
We report on a GPU implementation of the condensation method designed by Abdelmalek Salem and Kouachi Said for computing the determinant of a matrix. We consider two types of coefficients: modular integers and floating point numbers. We evaluate the performance of our code by measuring its effective bandwidth and argue that it is numerical stable in the floating point number case. In addition, we compare our code with serial implementation of determinant computation from well-known mathematical packages. Our results suggest that a GPU implementation of the condensation method has a large potential for improving those packages in terms of running time and numerical stability.
Evaluation of copy number variation detection for a SNP array platform
2014-01-01
Background Copy Number Variations (CNVs) are usually inferred from Single Nucleotide Polymorphism (SNP) arrays by use of some software packages based on given algorithms. However, there is no clear understanding of the performance of these software packages; it is therefore difficult to select one or several software packages for CNV detection based on the SNP array platform. We selected four publicly available software packages designed for CNV calling from an Affymetrix SNP array, including Birdsuite, dChip, Genotyping Console (GTC) and PennCNV. The publicly available dataset generated by Array-based Comparative Genomic Hybridization (CGH), with a resolution of 24 million probes per sample, was considered to be the “gold standard”. Compared with the CGH-based dataset, the success rate, average stability rate, sensitivity, consistence and reproducibility of these four software packages were assessed compared with the “gold standard”. Specially, we also compared the efficiency of detecting CNVs simultaneously by two, three and all of the software packages with that by a single software package. Results Simply from the quantity of the detected CNVs, Birdsuite detected the most while GTC detected the least. We found that Birdsuite and dChip had obvious detecting bias. And GTC seemed to be inferior because of the least amount of CNVs it detected. Thereafter we investigated the detection consistency produced by one certain software package and the rest three software suits. We found that the consistency of dChip was the lowest while GTC was the highest. Compared with the CNVs detecting result of CGH, in the matching group, GTC called the most matching CNVs, PennCNV-Affy ranked second. In the non-overlapping group, GTC called the least CNVs. With regards to the reproducibility of CNV calling, larger CNVs were usually replicated better. PennCNV-Affy shows the best consistency while Birdsuite shows the poorest. Conclusion We found that PennCNV outperformed the other three packages in the sensitivity and specificity of CNV calling. Obviously, each calling method had its own limitations and advantages for different data analysis. Therefore, the optimized calling methods might be identified using multiple algorithms to evaluate the concordance and discordance of SNP array-based CNV calling. PMID:24555668
Shearer, Barbara S.; Klatt, Carolyn; Nagy, Suzanne P.
2009-01-01
Objectives: The current study evaluates the results of a previously reported method for creating a core medical electronic journal collection for a new medical school library, validates the core collection created specifically to meet the needs of the new school, and identifies strategies for making cost-effective e-journal selection decisions. Methods: Usage data were extracted for four e-journal packages (Blackwell-Synergy, Cell Press, Lippincott Williams & Wilkins, and ScienceDirect). Usage was correlated with weighted point values assigned to a core list of journal titles, and each package was evaluated for relevancy and cost-effectiveness to the Florida State University College of Medicine (FSU COM) population. Results: The results indicated that the development of the core list was a valid method for creating a new twenty-first century, community-based medical school library. Thirty-seven journals are identified for addition to the FSU COM core list based on use by the COM, and areas of overlapping research interests between the university and the COM are identified based on use of specific journals by each population. Conclusions: The collection development approach that evolved at the FSU COM library was useful during the initial stages of identifying and evaluating journal selections and in assessing the relative value of a particular journal package for the FSU COM after the school was established. PMID:19404499
Halonen, Niina; Kilpijärvi, Joni; Sobocinski, Maciej; Datta-Chaudhuri, Timir; Hassinen, Antti; Prakash, Someshekar B; Möller, Peter; Abshire, Pamela; Kellokumpu, Sakari; Lloyd Spetz, Anita
2016-01-01
Cell viability monitoring is an important part of biosafety evaluation for the detection of toxic effects on cells caused by nanomaterials, preferably by label-free, noninvasive, fast, and cost effective methods. These requirements can be met by monitoring cell viability with a capacitance-sensing integrated circuit (IC) microchip. The capacitance provides a measurement of the surface attachment of adherent cells as an indication of their health status. However, the moist, warm, and corrosive biological environment requires reliable packaging of the sensor chip. In this work, a second generation of low temperature co-fired ceramic (LTCC) technology was combined with flip-chip bonding to provide a durable package compatible with cell culture. The LTCC-packaged sensor chip was integrated with a printed circuit board, data acquisition device, and measurement-controlling software. The packaged sensor chip functioned well in the presence of cell medium and cells, with output voltages depending on the medium above the capacitors. Moreover, the manufacturing of microfluidic channels in the LTCC package was demonstrated.
ERIC Educational Resources Information Center
Powell, Russell; Coldeway, Dan O.
An unsuccessful attempt was made to facilitate study behavior of Athabasca University learners through instruction in behavioral methods of self-control. The general procedure consisted of providing each student with a package containing instructions and materials for the self-application of the strategies of self-monitoring and standard setting.…
RELIC: a novel dye-bias correction method for Illumina Methylation BeadChip.
Xu, Zongli; Langie, Sabine A S; De Boever, Patrick; Taylor, Jack A; Niu, Liang
2017-01-03
The Illumina Infinium HumanMethylation450 BeadChip and its successor, Infinium MethylationEPIC BeadChip, have been extensively utilized in epigenome-wide association studies. Both arrays use two fluorescent dyes (Cy3-green/Cy5-red) to measure methylation level at CpG sites. However, performance difference between dyes can result in biased estimates of methylation levels. Here we describe a novel method, called REgression on Logarithm of Internal Control probes (RELIC) to correct for dye bias on whole array by utilizing the intensity values of paired internal control probes that monitor the two color channels. We evaluate the method in several datasets against other widely used dye-bias correction methods. Results on data quality improvement showed that RELIC correction statistically significantly outperforms alternative dye-bias correction methods. We incorporated the method into the R package ENmix, which is freely available from the Bioconductor website ( https://www.bioconductor.org/packages/release/bioc/html/ENmix.html ). RELIC is an efficient and robust method to correct for dye-bias in Illumina Methylation BeadChip data. It outperforms other alternative methods and conveniently implemented in R package ENmix to facilitate DNA methylation studies.
Virginia Transit Performance Evaluation Package (VATPEP).
DOT National Transportation Integrated Search
1987-01-01
The Virginia Transit Performance Evaluation Package (VATPEP), a computer software package, is documented. This is the computerized version of the methodology used by the Virginia Department of Transportation to evaluate the performance of public tran...
Computational methods for evaluation of cell-based data assessment--Bioconductor.
Le Meur, Nolwenn
2013-02-01
Recent advances in miniaturization and automation of technologies have enabled cell-based assay high-throughput screening, bringing along new challenges in data analysis. Automation, standardization, reproducibility have become requirements for qualitative research. The Bioconductor community has worked in that direction proposing several R packages to handle high-throughput data including flow cytometry (FCM) experiment. Altogether, these packages cover the main steps of a FCM analysis workflow, that is, data management, quality assessment, normalization, outlier detection, automated gating, cluster labeling, and feature extraction. Additionally, the open-source philosophy of R and Bioconductor, which offers room for new development, continuously drives research and improvement of theses analysis methods, especially in the field of clustering and data mining. This review presents the principal FCM packages currently available in R and Bioconductor, their advantages and their limits. Copyright © 2012 Elsevier Ltd. All rights reserved.
Charron, C; De Vaugelade, S; Richard, F; Largitte, A; Pirnay, S
2018-04-25
Nowadays, plastics are ubiquitous in our daily life. Most of materials used in cosmetic packaging are plastics. It is due to their great diversity of form and colour, their low cost and their easy production. The manufacture of plastic packaging requires the use of several additives such as plasticizers. These molecules are able to migrate from the packaging to the product [1] and can change the product composition, his properties and be harmful to the consumer health. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
76 FR 12729 - Cambridge Environmental Inc; Transfer of Data
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-08
...) and/ or electronic form. Due dates for each data package and/or assessment and/or project shall be...; Transfer of Data AGENCY: Environmental Protection Agency (EPA). ACTION: Notice. SUMMARY: This notice... evaluating assessments. This includes evaluating the applicability of the data and methods used in the...
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-09-01
This report describes the test site, equipment, and procedures and presents the data obtained during field testing at G.P.U. Genco Homer City Station, August 19--24, 1997. This was the third of three field tests that the US Environmental Protection Agency (EPA) conducted in 1997 as part of a major study to evaluate potential improvements to Method 3, EPA`s test method for measuring flue gas volumetric flow in stacks. The report also includes a Data Distribution Package, the official, complete repository of the results obtained at the test site.
Code of Federal Regulations, 2013 CFR
2013-01-01
... be given only for factors that are well documented in the application package and, in the opinion of... defined and supported by data. (f) Projects containing evaluation methods that are specific to the...
NASA Technical Reports Server (NTRS)
1981-01-01
The software package evaluation was designed to analyze commercially available, field-proven, production control or manufacturing resource planning management technology and software package. The analysis was conducted by comparing SRB production control software requirements and conceptual system design to software package capabilities. The methodology of evaluation and the findings at each stage of evaluation are described. Topics covered include: vendor listing; request for information (RFI) document; RFI response rate and quality; RFI evaluation process; and capabilities versus requirements.
Toxicokinetics (TK) provides a bridge between toxicity and exposure assessment by predicting tissue concentrations due to exposure, however traditional TK methods are resource intensive. Relatively high throughput TK (HTTK) methods have been used by the pharmaceutical industry to...
CATCHING THE WIND: A LOW COST METHOD FOR WIND POWER SITE ASSESSMENT
Our Phase I successes involve the installation of a wind monitoring station in Humboldt County, the evaluation of four different measure-correlate-predict methods for wind site assessment, and the creation of SWEET, an open source software package implementing the prediction ...
visCOS: An R-package to evaluate model performance of hydrological models
NASA Astrophysics Data System (ADS)
Klotz, Daniel; Herrnegger, Mathew; Wesemann, Johannes; Schulz, Karsten
2016-04-01
The evaluation of model performance is a central part of (hydrological) modelling. Much attention has been given to the development of evaluation criteria and diagnostic frameworks. (Klemeš, 1986; Gupta et al., 2008; among many others). Nevertheless, many applications exist for which objective functions do not yet provide satisfying summaries. Thus, the necessity to visualize results arises in order to explore a wider range of model capacities, be it strengths or deficiencies. Visualizations are usually devised for specific projects and these efforts are often not distributed to a broader community (e.g. via open source software packages). Hence, the opportunity to explicitly discuss a state-of-the-art presentation technique is often missed. We therefore present a comprehensive R-package for evaluating model performance by visualizing and exploring different aspects of hydrological time-series. The presented package comprises a set of useful plots and visualization methods, which complement existing packages, such as hydroGOF (Zambrano-Bigiarini et al., 2012). It is derived from practical applications of the hydrological models COSERO and COSEROreg (Kling et al., 2014). visCOS, providing an interface in R, represents an easy-to-use software package for visualizing and assessing model performance and can be implemented in the process of model calibration or model development. The package provides functions to load hydrological data into R, clean the data, process, visualize, explore and finally save the results in a consistent way. Together with an interactive zoom function of the time series, an online calculation of the objective functions for variable time-windows is included. Common hydrological objective functions, such as the Nash-Sutcliffe Efficiency and the Kling-Gupta Efficiency, can also be evaluated and visualized in different ways for defined sub-periods like hydrological years or seasonal sections. Many hydrologists use long-term water-balances as a pivotal tool in model evaluation. They allow inferences about different systematic model-shortcomings and are an efficient way for communicating these in practice (Schulz et al., 2015). The evaluation and construction of such water balances is implemented with the presented package. During the (manual) calibration of a model or in the scope of model development, many model runs and iterations are necessary. Thus, users are often interested in comparing different model results in a visual way in order to learn about the model and to analyse parameter-changes on the output. A method to illuminate these differences and the evolution of changes is also included. References: • Gupta, H.V.; Wagener, T.; Liu, Y. (2008): Reconciling theory with observations: elements of a diagnostic approach to model evaluation, Hydrol. Process. 22, doi: 10.1002/hyp.6989. • Klemeš, V. (1986): Operational testing of hydrological simulation models, Hydrolog. Sci. J., doi: 10.1080/02626668609491024. • Kling, H.; Stanzel, P.; Fuchs, M.; and Nachtnebel, H. P. (2014): Performance of the COSERO precipitation-runoff model under non-stationary conditions in basins with different climates, Hydrolog. Sci. J., doi: 10.1080/02626667.2014.959956. • Schulz, K., Herrnegger, M., Wesemann, J., Klotz, D. Senoner, T. (2015): Kalibrierung COSERO - Mur für Pro Vis, Verbund Trading GmbH (Abteilung STG), final report, Institute of Water Management, Hydrology and Hydraulic Engineering, University of Natural Resources and Applied Life Sciences, Vienna, Austria, 217pp. • Zambrano-Bigiarini, M; Bellin, A. (2010): Comparing Goodness-of-fit Measures for Calibration of Models Focused on Extreme Events. European Geosciences Union (EGU), Geophysical Research Abstracts 14, EGU2012-11549-1.
Evaluation of trade-offs in costs and environmental impacts for returnable packaging implementation
NASA Astrophysics Data System (ADS)
Jarupan, Lerpong; Kamarthi, Sagar V.; Gupta, Surendra M.
2004-02-01
The main thrust of returnable packaging these days is to provide logistical services through transportation and distribution of products and be environmentally friendly. Returnable packaging and reverse logistics concepts have converged to mitigate the adverse effect of packaging materials entering the solid waste stream. Returnable packaging must be designed by considering the trade-offs between costs and environmental impact to satisfy manufacturers and environmentalists alike. The cost of returnable packaging entails such items as materials, manufacturing, collection, storage and disposal. Environmental impacts are explicitly linked with solid waste, air pollution, and water pollution. This paper presents a multi-criteria evaluation technique to assist decision-makers for evaluating the trade-offs in costs and environmental impact during the returnable packaging design process. The proposed evaluation technique involves a combination of multiple objective integer linear programming and analytic hierarchy process. A numerical example is used to illustrate the methodology.
Rule-based optimization and multicriteria decision support for packaging a truck chassis
NASA Astrophysics Data System (ADS)
Berger, Martin; Lindroth, Peter; Welke, Richard
2017-06-01
Trucks are highly individualized products where exchangeable parts are flexibly combined to suit different customer requirements, this leading to a great complexity in product development. Therefore, an optimization approach based on constraint programming is proposed for automatically packaging parts of a truck chassis by following packaging rules expressed as constraints. A multicriteria decision support system is developed where a database of truck layouts is computed, among which interactive navigation then can be performed. The work has been performed in cooperation with Volvo Group Trucks Technology (GTT), from which specific rules have been used. Several scenarios are described where the methods developed can be successfully applied and lead to less time-consuming manual work, fewer mistakes, and greater flexibility in configuring trucks. A numerical evaluation is also presented showing the efficiency and practical relevance of the methods, which are implemented in a software tool.
Cengel, Ferhat
2016-01-01
Emergency physicians and radiologists have been increasingly encountering internal concealment of illegal drugs. The packages commonly contain powdered solid drugs such as cocaine, heroin, methamphetamine and hashish, but they may also contain cocaine in the liquid form. The second type of package has recently been more commonly encountered, and poses a greater diagnostic challenge. As clinical evaluation and laboratory tests frequently fail to make the correct diagnosis, imaging examination is typically required. Imaging methods assume a vital role in the diagnosis, follow-up and management. Abdominal X-ray, ultrasonography, CT and MRI are used for the imaging purposes. Among the aforementioned methods, low-dose CT is state-of-the-art in these cases. It is of paramount importance that radiologists have a full knowledge of the imaging characteristics of these packages and accurately guide physicians and security officials. PMID:26867003
Toxicokinetics (TK) provides a bridge between toxicity and exposure assessment by predicting tissue concentrations due to exposure. However traditional TK methods are resource intensive. Relatively high throughput TK (HTTK) methods have been used by the pharmaceutical industry to...
Quality evaluation of polypropylene packaged corn yogurt during storage
NASA Astrophysics Data System (ADS)
Aini, Nur; Prihananto, V.; Sustriawan, B.; Astuti, Y.; Maulina, M. R.
2018-01-01
Packaging is an important factor to control the process of quality decrease of any food product, including to determine the shelf life. The objective of this study was to determine changes quality of corn yogurt packaged using polypropylene. The method were using was package yogurt polypropylene, then it was stored in a refrigerator at 5, 10, or 15°C during 21 days. The yogurt was analysed every 7 days over a 21-day period. The results indicate that protein content decreased during storage, while the lactic acid bacteria, total acid, pH, viscosity, and total solids were increased. At the end of storage, the amount of lactic acid bacteria still fulfil the minimum requirements of a probiotic food, with a count of 6.407 log CFU/g. Overal scoring by panelist (scores ranged from 0 to 5) have a 4.78 at the beginning of storage. By the 21st day of storage, yogurt was packaging using transparent polypropylene having a score of 3.85, and that stored in opaque white packaging having a value of 3.95.
Consumer preferences for reduced packaging under economic instruments and recycling policy.
Yamaguchi, Keiko; Takeuchi, Kenji
2016-02-01
This study was conducted using a web-based survey and bidding game in contingent valuation method to evaluate consumer preferences for packaging with less material. Results revealed that people who live in a municipality implementing unit-based pricing of waste have a higher willingness-to-pay (WTP) for a product. Economic instruments can affect the purchase of products with reduced packaging because a higher disposal cost increases the attractiveness of source reduction. However, unit-based pricing combined with plastic separation for recycling reduces WTP. This result suggests that recycling policy weakens the effect of economic instruments on source reduction of waste. Copyright © 2015 Elsevier Ltd. All rights reserved.
Haegerich, Tamara M.; David-Ferdon, Corinne; Noonan, Rita K.; Manns, Brian J.; Billie, Holly C.
2016-01-01
Injury and violence prevention strategies have greater potential for impact when they are based on scientific evidence. Systematic reviews of the scientific evidence can contribute key information about which policies and programs might have the greatest impact when implemented. However, systematic reviews have limitations, such as lack of implementation guidance and contextual information, that can limit the application of knowledge. “Technical packages,” developed by knowledge brokers such as the federal government, nonprofit agencies, and academic institutions, have the potential to be an efficient mechanism for making information from systematic reviews actionable. Technical packages provide information about specific evidence-based prevention strategies, along with the estimated costs and impacts, and include accompanying implementation and evaluation guidance to facilitate adoption, implementation, and performance measurement. We describe how systematic reviews can inform the development of technical packages for practitioners, provide examples of technical packages in injury and violence prevention, and explain how enhancing review methods and reporting could facilitate the use and applicability of scientific evidence. PMID:27604301
LDRD final report on microencapsulated immunoreagents for development of one-step ELISA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Henderson, C.C.; Singh, A.K.
1997-08-01
Microencapsulation of biological macromolecules was investigated as a method for incorporating the necessary immunoreagents into an improved enzyme-linked immunosorbant assay (ELISA) package that would self-develop. This self-contained ELISA package would eliminate the need for a trained technician to perform multiple additions of immunoreagent to the assay. Microencapsulation by insolution drying was selected from the many available microencapsulation methods, and two satisfactory procedures for microencapsulation of proteins were established. The stability and potential for rapid release of protein from these microencapsulates was then evaluated. The results suggest that the chosen method for protein entrapment produces microcapsules with a considerable amount ofmore » protein in the walls making these particular microcapsules unsuitable for their intended use.« less
[Effects on performance of high-speed dental handpieces subjected to autoclaving].
Deng, Xiao-hong; Sun, Zheng; Su, Jing; Qiao, Hong; Xiao, Xiao
2006-07-01
To investigate the effects on performances of high-speed dental handpieces subjected to autoclaving. The method of trial used to evaluate the effect of autoclaving included that ten chemical and ten biological indicators were arranged in each trial group being set by one sort of temperature and sterilization time. The range of temperature was from 100 degrees C to 134 degrees C and the sterilization time was from 1 to 45 minutes. The reliability of autoclaving was evaluated by the result of chemical indicator and the endospores of Bacillus stearothermophilus subjected to autoclaving. Ten newly imported and ten new domestic dental handpieces in two different brands were used to carry out this trial. The effects produced by autoclaving on performances of dental handpieces subjected to different type autoclaves were evaluated by some parameters. The eligible outcome in killing test of the 221 sterilized dental handpieces proved that the sterilization effect of autoclaving on dental handpieces was reliable. The chemical indicators showed that under the condition of 121 degrees C it needed 20 minutes to reach sterilization standard in the inner package and only 15 minutes on the outer package, and under the condition of 134 degrees C it took 4 minutes to reach sterilization standard in the inner package while only 2 minutes on the outer package. This outcome proved that material with package was more time-consuming than that without package during autoclaving. Autoclaving has positive effects on the performance of dental handpieces, while the autoclave with less-time full sterilization cycle has less effect on it. The performance of dental handpieces sterilized by the autoclave with 6-minute full sterilization cycle might be restorable within certain times of sterilization cycle. The sterilization effect of autoclaving is reliable. In order to reduce the influence on the performance of dental handpieces subjected to autoclaving, it should be reasonable to use the autoclave by which a full sterilization cycle might take less time and no use of package.
ERIC Educational Resources Information Center
Mathrick, Rachel; Meagher, Tina; Norbury, Courtenay Frazier
2017-01-01
Background & Aims: We evaluated a structured intervention programme aimed at preparing adolescents with developmental language disorders for job interviews. Our primary outcome measures included change in ratings of verbal and non-verbal social communication behaviours evident during mock interviews. Methods & Procedures: In study 1, 12…
Tretola, M; Di Rosa, A R; Tirloni, E; Ottoboni, M; Giromini, C; Leone, F; Bernardi, C E M; Dell'Orto, V; Chiofalo, V; Pinotti, L
2017-08-01
The use of alternative feed ingredients in farm animal's diets can be an interesting choice from several standpoints, including safety. In this respect, this study investigated the safety features of selected former food products (FFPs) intended for animal nutrition produced in the framework of the IZS PLV 06/14 RC project by an FFP processing plant. Six FFP samples, both mash and pelleted, were analysed for the enumeration of total viable count (TVC) (ISO 4833), Enterobacteriaceae (ISO 21528-1), Escherichia coli (ISO 16649-1), coagulase-positive Staphylococci (CPS) (ISO 6888), presumptive Bacillus cereus and its spores (ISO 7932), sulphite-reducing Clostridia (ISO 7937), yeasts and moulds (ISO 21527-1), and the presence in 25 g of Salmonella spp. (ISO 6579). On the same samples, the presence of undesired ingredients, which can be identified as remnants of packaging materials, was evaluated by two different methods: stereomicroscopy according to published methods; and stereomicroscopy coupled with a computer vision system (IRIS Visual Analyzer VA400). All FFPs analysed were safe from a microbiological point of view. TVC was limited and Salmonella was always absent. When remnants of packaging materials were considered, the contamination level was below 0.08% (w/w). Of note, packaging remnants were found mainly from the 1-mm sieve mesh fractions. Finally, the innovative computer vision system demonstrated the possibility of rapid detection for the presence of packaging remnants in FFPs when combined with a stereomicroscope. In conclusion, the FFPs analysed in the present study can be considered safe, even though some improvements in FFP processing in the feeding plant can be useful in further reducing their microbial loads and impurity.
Shearer, Barbara S; Klatt, Carolyn; Nagy, Suzanne P
2009-04-01
The current study evaluates the results of a previously reported method for creating a core medical electronic journal collection for a new medical school library, validates the core collection created specifically to meet the needs of the new school, and identifies strategies for making cost-effective e-journal selection decisions. Usage data were extracted for four e-journal packages (Blackwell-Synergy, Cell Press, Lippincott Williams & Wilkins, and ScienceDirect). Usage was correlated with weighted point values assigned to a core list of journal titles, and each package was evaluated for relevancy and cost-effectiveness to the Florida State University College of Medicine (FSU COM) population. The results indicated that the development of the core list was a valid method for creating a new twenty-first century, community-based medical school library. Thirty-seven journals are identified for addition to the FSU COM core list based on use by the COM, and areas of overlapping research interests between the university and the COM are identified based on use of specific journals by each population. The collection development approach that evolved at the FSU COM library was useful during the initial stages of identifying and evaluating journal selections and in assessing the relative value of a particular journal package for the FSU COM after the school was established.
Liu, Bin; Wu, Hao; Zhang, Deyuan; Wang, Xiaolong; Chou, Kuo-Chen
2017-02-21
To expedite the pace in conducting genome/proteome analysis, we have developed a Python package called Pse-Analysis. The powerful package can automatically complete the following five procedures: (1) sample feature extraction, (2) optimal parameter selection, (3) model training, (4) cross validation, and (5) evaluating prediction quality. All the work a user needs to do is to input a benchmark dataset along with the query biological sequences concerned. Based on the benchmark dataset, Pse-Analysis will automatically construct an ideal predictor, followed by yielding the predicted results for the submitted query samples. All the aforementioned tedious jobs can be automatically done by the computer. Moreover, the multiprocessing technique was adopted to enhance computational speed by about 6 folds. The Pse-Analysis Python package is freely accessible to the public at http://bioinformatics.hitsz.edu.cn/Pse-Analysis/, and can be directly run on Windows, Linux, and Unix.
Al-Delaimy, Ahmed K; Al-Mekhlafi, Hesham M; Lim, Yvonne A L; Nasr, Nabil A; Sady, Hany; Atroosh, Wahib M; Mahmud, Rohela
2014-09-02
This study was carried out to develop a health education learning package (HELP) about soil-transmitted helminth (STH) infections, and to evaluate what impact such a package could have in terms of reducing the incidence and intensity of STH infections among Orang Asli schoolchildren in Pahang, Malaysia. To identify the key risk factors of STH in Orang Asli communities, we applied an extensive mixed methods approach which involved an intensive literature review, as well as community-based discussions with children, their parents, teachers and health personnel, whilst also placing the children under direct observation. To evaluate the package, 317 children from two schools in Lipis, Pahang were screened for STH infections, treated by a 3-day course of albendazole and then followed up over the next 6 months. The knowledge of teachers, parents and children towards STH infections were assessed at baseline and after 3 months. The developed package consists of a half day workshop for teachers, a teacher's guide book to STH infections, posters, a comic book, a music video, a puppet show, drawing activities and an aid kit. The package was well-received with effective contributions being made by teachers, children and their parents. The incidence rates of hookworm infection at different assessment points were significantly lower among children in the intervention school compared to those in the control school. Similarly, the intensity of trichuriasis, ascariasis and hookworm infections were found to be significantly lower among children in the HELP group compared to those in the control group (P < 0.05). Moreover, the package significantly improved the knowledge, attitude and practices (KAP) of Orang Asli people and the knowledge of teachers towards STH infections. A school-based health education learning package (HELP) was developed which displayed a significant impact in terms of reducing the intensity of all three main STH infections, as well as in reducing the prevalence of hookworm infections. Moreover, the knowledge levels of both teachers and the Orang Asli population regarding STH was significantly improved, a fact which greatly helped in attracting community participation and thus raising the general level of awareness regarding these forms of infections.
Victor, Ken G; Levac, Lauren; Timmins, Michael; Veale, James
2017-01-01
USP <1207.1> Section 3.5 states that "A deterministic leak test method having the ability to detect leaks at the product's maximum allowable leakage limit is preferred when establishing the inherent integrity of a container-closure system." Ideally, container closure integrity of parenteral packaging would be evaluated by measuring a physical property that is sensitive to the presence of any package defect that breaches package integrity by increasing its leakage above its maximum allowable leakage limit. The primary goals of the work presented herein were to demonstrate the viability of the nondestructive, deterministic method known as laser-based gas headspace analysis for evaluating container closure integrity and to provide a physical model for predicting leak rates for a variety of container volumes, headspace conditions, and defect sizes. The results demonstrate that laser-based headspace analysis provides sensitive, accurate, and reproducible measurements of the gas ingress into glass vial-stopper package assemblies that are under either diffusive or effusive leak conditions. Two different types of positive controls were examined. First, laser-drilled micro-holes in thin metal disks that were crimped on top of 15R glass vials served as positive controls with a well-characterized defect geometry. For these, a strong correlation was observed between the measured ingress parameter and the size of the defect for both diffusive and effusive conditions. Second, laser-drilled holes in the wall of glass vials served as controls that more closely simulate real-world defects. Due to their complex defect geometries, their diffusive and effusive ingress parameters did not necessarily correlate; this is an important observation that has significant implications for standardizing the characterization of container defects. Regardless, laser-based headspace analysis could readily differentiate positive and negative controls for all leak conditions, and the results provide a guide for method development of container closure integrity tests. LAY ABSTRACT: The new USP 39 <1207>, "Package Integrity Evaluation-Sterile Products", states in section 3.4.1: "tracer gas tests performed using … laser-based gas headspace analysis [have] been shown to be sensitive enough to quantitatively analyze leakage through the smallest leak paths found to pose the smallest chance of liquid leakage or microbial ingress in rigid packaging." In addition, USP <1207> also states that "for such methods, the limit of detection can be mathematically predicted on the basis of gas flow kinetics." Using the above statements as a foundation, this paper presents a theoretical basis for predicting the gas ingress through well-defined defects in product vials sealed under a variety of headspace conditions. These calculated predictions were experimentally validated by comparing them to measurements of changes in the headspace oxygen content or total pressure for several different positive controls using laser-based headspace analysis. The results demonstrated that laser-based headspace analysis can, by readily differentiating between negative controls and positive controls with a range of defect sizes on the micron scale, be used to assess container closure integrity. The work also demontrated that caution must be used when attempting to correlate a leak rate to an idealized defect-size parameter. © PDA, Inc. 2017.
Patel, Jayshree; Mulhall, Brian; Wolf, Heinz; Klohr, Steven; Guazzo, Dana Morton
2011-01-01
A leak test performed according to ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method was developed and validated for container-closure integrity verification of a lyophilized product in a parenteral vial package system. This nondestructive leak test method is intended for use in manufacturing as an in-process package integrity check, and for testing product stored on stability in lieu of sterility tests. Method development and optimization challenge studies incorporated artificially defective packages representing a range of glass vial wall and sealing surface defects, as well as various elastomeric stopper defects. Method validation required 3 days of random-order replicate testing of a test sample population of negative-control, no-defect packages and positive-control, with-defect packages. Positive-control packages were prepared using vials each with a single hole laser-drilled through the glass vial wall. Hole creation and hole size certification was performed by Lenox Laser. Validation study results successfully demonstrated the vacuum decay leak test method's ability to accurately and reliably detect those packages with laser-drilled holes greater than or equal to approximately 5 μm in nominal diameter. All development and validation studies were performed at Whitehouse Analytical Laboratories in Whitehouse, NJ, under the direction of consultant Dana Guazzo of RxPax, LLC, using a VeriPac 455 Micro Leak Test System by Packaging Technologies & Inspection (Tuckahoe, NY). Bristol Myers Squibb (New Brunswick, NJ) fully subsidized all work. A leak test performed according to ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method was developed and validated to detect defects in stoppered vial packages containing lyophilized product for injection. This nondestructive leak test method is intended for use in manufacturing as an in-process package integrity check, and for testing product stored on stability in lieu of sterility tests. Test method validation study results proved the method capable of detecting holes laser-drilled through the glass vial wall greater than or equal to 5 μm in nominal diameter. Total test time is less than 1 min per package. All method development and validation studies were performed at Whitehouse Analytical Laboratories in Whitehouse, NJ, under the direction of consultant Dana Guazzo of RxPax, LLC, using a VeriPac 455 Micro Leak Test System by Packaging Technologies & Inspection (Tuckahoe, NY). Bristol Myers Squibb (New Brunswick, NJ) fully subsidized all work.
Evaluation and selection of open-source EMR software packages based on integrated AHP and TOPSIS.
Zaidan, A A; Zaidan, B B; Al-Haiqi, Ahmed; Kiah, M L M; Hussain, Muzammil; Abdulnabi, Mohamed
2015-02-01
Evaluating and selecting software packages that meet the requirements of an organization are difficult aspects of software engineering process. Selecting the wrong open-source EMR software package can be costly and may adversely affect business processes and functioning of the organization. This study aims to evaluate and select open-source EMR software packages based on multi-criteria decision-making. A hands-on study was performed and a set of open-source EMR software packages were implemented locally on separate virtual machines to examine the systems more closely. Several measures as evaluation basis were specified, and the systems were selected based a set of metric outcomes using Integrated Analytic Hierarchy Process (AHP) and TOPSIS. The experimental results showed that GNUmed and OpenEMR software can provide better basis on ranking score records than other open-source EMR software packages. Copyright © 2014 Elsevier Inc. All rights reserved.
Nuclear criticality safety evaluation of SRS 9971 shipping package
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vescovi, P.J.
1993-02-01
This evaluation is requested to revise the criticality evaluation used to generate Chapter 6 (Criticality Evaluation) of the Safety Analysis Report for Packaging (SARP) for shipment Of UO{sub 3} product from the Uranium Solidification Facility (USF) in the SRS 9971 shipping package. The pertinent document requesting this evaluation is included as Attachment I. The results of the evaluation are given in Attachment II which is written as Chapter 6 of a NRC format SARP.
Diagnostic evaluation of three cardiac software packages using a consecutive group of patients
2011-01-01
Purpose The aim of this study was to compare the diagnostic performance of the three software packages 4DMSPECT (4DM), Emory Cardiac Toolbox (ECTb), and Cedars Quantitative Perfusion SPECT (QPS) for quantification of myocardial perfusion scintigram (MPS) using a large group of consecutive patients. Methods We studied 1,052 consecutive patients who underwent 2-day stress/rest 99mTc-sestamibi MPS studies. The reference/gold-standard classifications for the MPS studies were obtained from three physicians, with more than 25 years each of experience in nuclear cardiology, who re-evaluated all MPS images. Automatic processing was carried out using 4DM, ECTb, and QPS software packages. Total stress defect extent (TDE) and summed stress score (SSS) based on a 17-segment model were obtained from the software packages. Receiver-operating characteristic (ROC) analysis was performed. Results A total of 734 patients were classified as normal and the remaining 318 were classified as having infarction and/or ischemia. The performance of the software packages calculated as the area under the SSS ROC curve were 0.87 for 4DM, 0.80 for QPS, and 0.76 for ECTb (QPS vs. ECTb p = 0.03; other differences p < 0.0001). The area under the TDE ROC curve were 0.87 for 4DM, 0.82 for QPS, and 0.76 for ECTb (QPS vs. ECTb p = 0.0005; other differences p < 0.0001). Conclusion There are considerable differences in performance between the three software packages with 4DM showing the best performance and ECTb the worst. These differences in performance should be taken in consideration when software packages are used in clinical routine or in clinical studies. PMID:22214226
Ultrasonic test of resistance spot welds based on wavelet package analysis.
Liu, Jing; Xu, Guocheng; Gu, Xiaopeng; Zhou, Guanghao
2015-02-01
In this paper, ultrasonic test of spot welds for stainless steel sheets has been studied. It is indicated that traditional ultrasonic signal analysis in either time domain or frequency domain remains inadequate to evaluate the nugget diameter of spot welds. However, the method based on wavelet package analysis in time-frequency domain can easily distinguish the nugget from the corona bond by extracting high-frequency signals in different positions of spot welds, thereby quantitatively evaluating the nugget diameter. The results of ultrasonic test fit the actual measured value well. Mean value of normal distribution of error statistics is 0.00187, and the standard deviation is 0.1392. Furthermore, the quality of spot welds was evaluated, and it is showed ultrasonic nondestructive test based on wavelet packet analysis can be used to evaluate the quality of spot welds, and it is more reliable than single tensile destructive test. Copyright © 2014 Elsevier B.V. All rights reserved.
77 FR 67678 - Content Specifications and Shielding Evaluations for Type B Transportation Packages
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-13
...The U.S. Nuclear Regulatory Commission (NRC or the Commission) is issuing for public comment Draft Regulatory Issue Summary (RIS) 2012-XX, ``Content Specifications and Shielding Evaluations for Type B Transportation Packages.'' This RIS clarifies the NRC's use of staff guidance in NUREG-1609, ``Standard Review Plan for Transport Packages for Radioactive Material,'' for the review of content specifications and shielding evaluations included in the Certificates of Compliance (CoC) and safety analysis reports (SARs) for Type B transportation packages.
Two autowire versions for CDC-3200 and IBM-360
NASA Technical Reports Server (NTRS)
Billingsley, J. B.
1972-01-01
Microelectronics program was initiated to evaluate circuitry, packaging methods, and fabrication approaches necessary to produce completely procured logic system. Two autowire programs were developed for CDC-3200 and IBM-360 computers for use in designing logic systems.
Conformity of commercial oral single solid unit dose packages in hospital pharmacy practice.
Thibault, Maxime; Prot-Labarthe, Sonia; Bussières, Jean-François; Lebel, Denis
2008-06-01
There are limited published data on the labelling of single unit dose packages in hospitals. The study was conducted in three large hospitals (two adult and one paediatric) in the metropolitan Montreal area, Quebec, Canada. The objective is to evaluate the labelling of commercial oral single solid unit dose packages available in Canadian urban hospital pharmacy practice. The study endpoint was the labelling conformity of each unit dose package for each criterion and overall for each manufacturer. Complete labelling of unit dose packages should include the following information: (1) brand name, (2) international non-proprietary name or generic name, (3) dosage, (4) pharmaceutical form, (5) manufacturer's name, (6) expiry date, (7) batch number and (8) drug identification number. We also evaluated the ease with which a single unit dose package is detached from a multiple unit dose package for quick, easy and safe use by pharmacy staff. Conformity levels were compared between brand-name and generic packages. A total of 124 different unit dose packages were evaluated. The level of conformity of each criterion varied between 19 and 50%. Only 43% of unit dose packages provided an easy-to-detach system for single doses. Among the 14 manufacturers with three or more unit dose packages evaluated, eight (57%) had a conformity level less than 50%. This study describes the conformity of commercial oral single solid unit dose packages in hospital pharmacy practice in Quebec. A large proportion of unit dose packages do not conform to a set of nine criteria set out in the guidelines of the American Society of Health-System Pharmacists and the Canadian Society of Hospital Pharmacists.
Recent application of quantification II in Japanese medical research.
Suzuki, T; Kudo, A
1979-01-01
Hayashi's Quantification II is a method of multivariate discrimination analysis to manipulate attribute data as predictor variables. It is very useful in the medical research field for estimation, diagnosis, prognosis, evaluation of epidemiological factors, and other problems based on multiplicity of attribute data. In Japan, this method is so well known that most of the computer program packages include the Hayashi Quantification, but it seems to be yet unfamiliar with the method for researchers outside Japan. In view of this situation, we introduced 19 selected articles of recent applications of the Quantification II in Japanese medical research. In reviewing these papers, special mention is made to clarify how the researchers were satisfied with findings provided by the method. At the same time, some recommendations are made about terminology and program packages. Also a brief discussion of the background of the quantification methods is given with special reference to the Behaviormetric Society of Japan. PMID:540587
Jaffer, Usman; Normahani, Pasha; Singh, Prashant; Aslam, Mohammed; Standfield, Nigel J
2015-01-01
In vascular surgery, duplex ultrasonography is a valuable diagnostic tool in patients with peripheral vascular disease, and there is increasing demand for vascular surgeons to be able to perform duplex scanning. This study evaluates the role of a novel simulation training package on vascular ultrasound (US) skill acquisition. A total of 19 novices measured predefined stenosis in a simulated pulsatile vessel using both peak systolic velocity ratio (PSVR) and diameter reduction (DR) methods before and after a short period of training using a simulated training package. The training package consisted of a simulated pulsatile vessel phantom, a set of instructional videos, duplex ultrasound objective structured assessment of technical skills (DUOSATS) tool, and a portable US scanner. Quantitative metrics (procedure time, percentage error using PSVR and DR methods, DUOSAT scores, and global rating scores) before and after training were compared. Subjects spent a median time of 144 mins (IQR: 60-195) training using the simulation package. Subjects exhibited statistically significant improvements when comparing pretraining and posttraining DUOSAT scores (pretraining = 17 [16-19.3] vs posttraining = 30 [27.8-31.8]; p < 0.01), global rating score (pretraining = 1 [1-2] vs posttraining = 4 [3.8-4]; p < 0.01), percentage error using both the DR (pretraining = 12.6% [9-29.6] vs posttraining = 10.3% [8.9-11.1]; p = 0.03) and PSVR (pretraining = 60% [40-60] vs posttraining = 20% [6.7-20]; p < 0.01) methods. In this study, subjects with no previous practical US experience developed the ability to both acquire and interpret arterial duplex images in a pulsatile simulated phantom following a short period of goal direct training using a simulation training package. A simulation training package may be a valuable tool for integration into a vascular training program. However, further work is needed to explore whether these newly attained skills are translated into clinical assessment. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Eichenlaub, Carl T.; Harper, C. Douglas; Hird, Geoffrey
1993-01-01
Life-critical applications warrant a higher level of software reliability than has yet been achieved. Since it is not certain that traditional methods alone can provide the required ultra reliability, new methods should be examined as supplements or replacements. This paper describes a mathematical counterpart to the traditional process of empirical testing. ORA's Penelope verification system is demonstrated as a tool for evaluating the correctness of Ada software. Grady Booch's Ada calendar utility package, obtained through NASA, was specified in the Larch/Ada language. Formal verification in the Penelope environment established that many of the package's subprograms met their specifications. In other subprograms, failed attempts at verification revealed several errors that had escaped detection by testing.
How tobacco companies have used package quantity for consumer targeting.
Persoskie, Alexander; Donaldson, Elisabeth A; Ryant, Chase
2018-05-31
Package quantity refers to the number of cigarettes or amount of other tobacco product in a package. Many countries restrict minimum cigarette package quantities to avoid low-cost packs that may lower barriers to youth smoking. We reviewed Truth Tobacco Industry Documents to understand tobacco companies' rationales for introducing new package quantities, including companies' expectations and research regarding how package quantity may influence consumer behaviour. A snowball sampling method (phase 1), a static search string (phase 2) and a follow-up snowball search (phase 3) identified 216 documents, mostly from the 1980s and 1990s, concerning cigarettes (200), roll-your-own tobacco (9), smokeless tobacco (6) and 'smokeless cigarettes' (1). Companies introduced small and large packages to motivate brand-switching and continued use among current users when faced with low market share or threats such as tax-induced price increases or competitors' use of price promotions. Companies developed and evaluated package quantities for specific brands and consumer segments. Large packages offered value-for-money and matched long-term, heavy users' consumption rates. Small packages were cheaper, matched consumption rates of newer and lighter users, and increased products' novelty, ease of carrying and perceived freshness. Some users also preferred small packages as a way to try to limit consumption or quit. Industry documents speculated about many potential effects of package quantity on appeal and use, depending on brand and consumer segment. The search was non-exhaustive, and we could not assess the quality of much of the research or other information on which the documents relied. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Nuclear criticality safety evaluation of SRS 9971 shipping package. [SRS (Savannah River Site)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vescovi, P.J.
1993-02-01
This evaluation is requested to revise the criticality evaluation used to generate Chapter 6 (Criticality Evaluation) of the Safety Analysis Report for Packaging (SARP) for shipment Of UO[sub 3] product from the Uranium Solidification Facility (USF) in the SRS 9971 shipping package. The pertinent document requesting this evaluation is included as Attachment I. The results of the evaluation are given in Attachment II which is written as Chapter 6 of a NRC format SARP.
Quantiprot - a Python package for quantitative analysis of protein sequences.
Konopka, Bogumił M; Marciniak, Marta; Dyrka, Witold
2017-07-17
The field of protein sequence analysis is dominated by tools rooted in substitution matrices and alignments. A complementary approach is provided by methods of quantitative characterization. A major advantage of the approach is that quantitative properties defines a multidimensional solution space, where sequences can be related to each other and differences can be meaningfully interpreted. Quantiprot is a software package in Python, which provides a simple and consistent interface to multiple methods for quantitative characterization of protein sequences. The package can be used to calculate dozens of characteristics directly from sequences or using physico-chemical properties of amino acids. Besides basic measures, Quantiprot performs quantitative analysis of recurrence and determinism in the sequence, calculates distribution of n-grams and computes the Zipf's law coefficient. We propose three main fields of application of the Quantiprot package. First, quantitative characteristics can be used in alignment-free similarity searches, and in clustering of large and/or divergent sequence sets. Second, a feature space defined by quantitative properties can be used in comparative studies of protein families and organisms. Third, the feature space can be used for evaluating generative models, where large number of sequences generated by the model can be compared to actually observed sequences.
Corrosion of silicon integrated circuits and lifetime predictions in implantable electronic devices.
Vanhoestenberghe, A; Donaldson, N
2013-06-01
Corrosion is a prime concern for active implantable devices. In this paper we review the principles underlying the concepts of hermetic packages and encapsulation, used to protect implanted electronics, some of which remain widely overlooked. We discuss how technological advances have created a need to update the way we evaluate the suitability of both protection methods. We demonstrate how lifetime predictability is lost for very small hermetic packages and introduce a single parameter to compare different packages, with an equation to calculate the minimum sensitivity required from a test method to guarantee a given lifetime. In the second part of this paper, we review the literature on the corrosion of encapsulated integrated circuits (ICs) and, following a new analysis of published data, we propose an equation for the pre-corrosion lifetime of implanted ICs, and discuss the influence of the temperature, relative humidity, encapsulation and field-strength. As any new protection will be tested under accelerated conditions, we demonstrate the sensitivity of acceleration factors to some inaccurately known parameters. These results are relevant for any application of electronics working in a moist environment. Our comparison of encapsulation and hermetic packages suggests that both concepts may be suitable for future implants.
Hazard classification assessment for the MC3423 detonator shipping package
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, R.B.
1981-11-05
An investigation was made to determine whether the MC3423 detonator should be assigned a DOT hazard classification of Detonating Fuze, Class C Explosive, per Federal Register 49 CFR 173.113, when packaged as specified. This study covers two propagation tests which evaluated the effects of two orientations of the MC3423 in its shipping tray. The method of testing was approved by DOE, Albuquerque Operations Office. Test data led to the recommended hazard classification of Detonating Fuze, Class C Explosive for both orientations of the detonator.
NASA Astrophysics Data System (ADS)
Anwar, R. W.; Sugiarto; Warsiki, E.
2018-03-01
Contamination after the processing of products during storage, distribution and marketing is one of the main causes of food safety issues. Handling of food products after processing can be done during the packaging process. Antimicrobial (AM) active packaging is one of the concept of packaging product development by utilize the interaction between the product and the packaging environment that can delay the bacterial damage by killing or reducing bacterial growth. The active system is formed by incorporating an antimicrobial agent against a packaging matrix that will function as a carrier. Many incorporation methods have been developed in this packaging-making concept which were direct mixing, polishing, and encapsulation. The aims of this research were to examine the different of the AM packaging performances including its stability and effectiveness of its function that would be produced by three different methods. The stability of the packaging function was analyzed by looking at the diffusivity of the active ingredient to the matrix using SEM. The effectiveness was analyzed by the ability of the packaging to prevent the growing of the microbial. The results showed that different incorporation methods resulted on different characteristics of the AM packaging.
PACKAGE PLANTS FOR SMALL SYSTEMS: A FIELD STUDY
A joint field study was conducted by AWWA and the Drinking Water Research Division of USEPA to evaluate existing small community systems that use package plant technology. Forty-eight package plant systems representing a geographic and technological cross section were evaluated t...
Haegerich, Tamara M; David-Ferdon, Corinne; Noonan, Rita K; Manns, Brian J; Billie, Holly C
2016-09-07
Injury and violence prevention strategies have greater potential for impact when they are based on scientific evidence. Systematic reviews of the scientific evidence can contribute key information about which policies and programs might have the greatest impact when implemented. However, systematic reviews have limitations, such as lack of implementation guidance and contextual information, that can limit the application of knowledge. "Technical packages," developed by knowledge brokers such as the federal government, nonprofit agencies, and academic institutions, have the potential to be an efficient mechanism for making information from systematic reviews actionable. Technical packages provide information about specific evidence-based prevention strategies, along with the estimated costs and impacts, and include accompanying implementation and evaluation guidance to facilitate adoption, implementation, and performance measurement. We describe how systematic reviews can inform the development of technical packages for practitioners, provide examples of technical packages in injury and violence prevention, and explain how enhancing review methods and reporting could facilitate the use and applicability of scientific evidence. © The Author(s) 2016.
78 FR 26090 - Content Specifications and Shielding Evaluations for Type B Transportation Packages
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-03
...The U.S. Nuclear Regulatory Commission (NRC) is issuing Regulatory Issue Summary (RIS) 2013-04, ``Content Specifications and Shielding Evaluations for Type B Transportation Packages.'' This RIS clarifies the NRC's use of staff guidance in NUREG-1609, ``Standard Review Plan for Transport Packages for Radioactive Material,'' for the review of content specifications and shielding evaluations included in the Certificates of Compliance (CoC) and safety analysis reports (SARs) for Type B transportation packages. The RIS does not impose any additional regulatory requirements on NRC licensees.
Uppal, Kamaldeep K; Getty, Kelly J K; Boyle, Elizabeth A E; Harper, Nigel M; Lobaton-Sulabo, April Shayne S; Barry, Bruce
2012-01-01
The objective of our study was to determine effect of packaging method and storage time on reducing Listeria monocytogenes in shelf-stable meat snacks. Commercially available kippered beef steak strips and turkey tenders were dipped into a 5-strain L. monocytogenes cocktail, and dried at 23 °C until a water activity of 0.80 was achieved. Inoculated samples were packaged with 4 treatments: (1) vacuum, (2) nitrogen flushed with oxygen scavenger, (3) heat sealed with oxygen scavenger, and (4) heat sealed without oxygen scavenger. Samples were stored at 23 °C and evaluated for L. monocytogenes levels at 0, 24, 48, and 72 h. Initial levels (time 0) of L. monocytogenes were approximately 5.7 log CFU/cm² for steak and tenders. After 24 h of storage time, a 1 log CFU/cm² reduction of L. monocytogenes was observed for turkey tenders for all packaging treatments. After 48 h, turkey tenders showed >1 log CFU/cm² reduction of L. monocytogenes for all packaging treatments except for vacuum, where only 0.9 log CFU/cm² reduction was observed. After 72 h, reductions for all packaging treatments for turkey tenders ranged from 1.5 to 2.4 log CFU/cm². For kippered beef steak, there was no interaction between the packaging treatments and all storage times (P > 0.05) whereas, time was different (P <0.05). For kippered beef steak, there was 1 log reduction of L. monocytogenes at 24 and 48 h of storage times at 23 °C for all packaging treatments and a 2.1 log CFU/ cm² L. monocytogenes reduction at 72 h of storage time. Processors of kippered beef steak and turkey tenders could use a combination of vacuum or nitrogen-flushing or heat sealed with an oxygen scavenger packaging methods and a holding time of 24 h prior to shipping to reduce potential L. monocytogenes numbers by ≥1 log. However, processors should be encouraged to hold packaged product a minimum of 72 h to enhance the margin of safety for L. monocytogenes control. © 2011 Institute of Food Technologists®
Safety evaluation for packaging transportation of equipment for tank 241-C-106 waste sluicing system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Calmus, D.B.
1994-08-25
A Waste Sluicing System (WSS) is scheduled for installation in nd waste storage tank 241-C-106 (106-C). The WSS will transfer high rating sludge from single shell tank 106-C to double shell waste tank 241-AY-102 (102-AY). Prior to installation of the WSS, a heel pump and a transfer pump will be removed from tank 106-C and an agitator pump will be removed from tank 102-AY. Special flexible receivers will be used to contain the pumps during removal from the tanks. After equipment removal, the flexible receivers will be placed in separate containers (packagings). The packaging and contents (packages) will be transferredmore » from the Tank Farms to the Central Waste Complex (CWC) for interim storage and then to T Plant for evaluation and processing for final disposition. Two sizes of packagings will be provided for transferring the equipment from the Tank Farms to the interim storage facility. The packagings will be designated as the WSSP-1 and WSSP-2 packagings throughout the remainder of this Safety Evaluation for Packaging (SEP). The WSSP-1 packagings will transport the heel and transfer pumps from 106-C and the WSSP-2 packaging will transport the agitator pump from 102-AY. The WSSP-1 and WSSP-2 packagings are similar except for the length.« less
Evaluation of contents-based image retrieval methods for a database of logos on drug tablets
NASA Astrophysics Data System (ADS)
Geradts, Zeno J.; Hardy, Huub; Poortman, Anneke; Bijhold, Jurrien
2001-02-01
In this research an evaluation has been made of the different ways of contents based image retrieval of logos of drug tablets. On a database of 432 illicitly produced tablets (mostly containing MDMA), we have compared different retrieval methods. Two of these methods were available from commercial packages, QBIC and Imatch, where the implementation of the contents based image retrieval methods are not exactly known. We compared the results for this database with the MPEG-7 shape comparison methods, which are the contour-shape, bounding box and region-based shape methods. In addition, we have tested the log polar method that is available from our own research.
19 CFR 10.539 - Retail packaging materials and containers.
Code of Federal Regulations, 2010 CFR
2010-04-01
...-Singapore Free Trade Agreement Rules of Origin § 10.539 Retail packaging materials and containers. Packaging... requirement. The United States importer of good C decides to use the build-down method, RVC=((AV−VNM)/AV... content requirement. In applying this method, the non-originating blister packages are taken into account...
Comparison of rotation algorithms for digital images
NASA Astrophysics Data System (ADS)
Starovoitov, Valery V.; Samal, Dmitry
1999-09-01
The paper presents a comparative study of several algorithms developed for digital image rotation. No losing generality we studied gray scale images. We have tested methods preserving gray values of the original images, performing some interpolation and two procedures implemented into the Corel Photo-paint and Adobe Photoshop soft packages. By the similar way methods for rotation of color images may be evaluated also.
Thermal shock testing for assuring reliability of glass-sealed microelectronic packages
NASA Technical Reports Server (NTRS)
Thomas, Walter B., III; Lewis, Michael D.
1991-01-01
Tests were performed to determine if thermal shocking is destructive to glass-to-metal seal microelectronic packages and if thermal shock step stressing can compare package reliabilities. Thermal shocking was shown to be not destructive to highly reliable glass seals. Pin-pull tests used to compare the interfacial pin glass strengths showed no differences between thermal shocked and not-thermal shocked headers. A 'critical stress resistance temperature' was not exhibited by the 14 pin Dual In-line Package (DIP) headers evaluated. Headers manufactured in cryogenic nitrogen based and exothermically generated atmospheres showed differences in as-received leak rates, residual oxide depths and pin glass interfacial strengths; these were caused by the different manufacturing methods, in particular, by the chemically etched pins used by one manufacturer. Both header types passed thermal shock tests to temperature differentials of 646 C. The sensitivity of helium leak rate measurements was improved up to 70 percent by baking headers for two hours at 200 C after thermal shocking.
Madrigal, Pedro
2017-03-01
Computational evaluation of variability across DNA or RNA sequencing datasets is a crucial step in genomic science, as it allows both to evaluate reproducibility of biological or technical replicates, and to compare different datasets to identify their potential correlations. Here we present fCCAC, an application of functional canonical correlation analysis to assess covariance of nucleic acid sequencing datasets such as chromatin immunoprecipitation followed by deep sequencing (ChIP-seq). We show how this method differs from other measures of correlation, and exemplify how it can reveal shared covariance between histone modifications and DNA binding proteins, such as the relationship between the H3K4me3 chromatin mark and its epigenetic writers and readers. An R/Bioconductor package is available at http://bioconductor.org/packages/fCCAC/ . pmb59@cam.ac.uk. Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press.
Package for integrated optic circuit and method
Kravitz, Stanley H.; Hadley, G. Ronald; Warren, Mial E.; Carson, Richard F.; Armendariz, Marcelino G.
1998-01-01
A structure and method for packaging an integrated optic circuit. The package comprises a first wall having a plurality of microlenses formed therein to establish channels of optical communication with an integrated optic circuit within the package. A first registration pattern is provided on an inside surface of one of the walls of the package for alignment and attachment of the integrated optic circuit. The package in one embodiment may further comprise a fiber holder for aligning and attaching a plurality of optical fibers to the package and extending the channels of optical communication to the fibers outside the package. In another embodiment, a fiber holder may be used to hold the fibers and align the fibers to the package. The fiber holder may be detachably connected to the package.
Package for integrated optic circuit and method
Kravitz, S.H.; Hadley, G.R.; Warren, M.E.; Carson, R.F.; Armendariz, M.G.
1998-08-04
A structure and method are disclosed for packaging an integrated optic circuit. The package comprises a first wall having a plurality of microlenses formed therein to establish channels of optical communication with an integrated optic circuit within the package. A first registration pattern is provided on an inside surface of one of the walls of the package for alignment and attachment of the integrated optic circuit. The package in one embodiment may further comprise a fiber holder for aligning and attaching a plurality of optical fibers to the package and extending the channels of optical communication to the fibers outside the package. In another embodiment, a fiber holder may be used to hold the fibers and align the fibers to the package. The fiber holder may be detachably connected to the package. 6 figs.
2012-01-01
Introduction: The Family Smoking Prevention and Tobacco Control Act (the “Act”), enacted in June 2009, gave the U.S. Food and Drug Administration authority to regulate tobacco products. The current paper reviews the provisions for packaging and labeling, including the existing evidence and research priorities. Methods: Narrative review using electronic literature search of published and unpublished sources in 3 primary areas: health warnings, constituent labeling, and prohibitions on the promotional elements of packaging. Results: The Act requires 9 pictorial health warnings covering half of cigarette packages and 4 text warnings covering 30% of smokeless tobacco packages. The Act also prohibits potentially misleading information on packaging, including the terms “light” and “mild,” and provides a mandate to require disclosure of chemical constituents on packages. Many of the specific regulatory provisions are based on the extent to which they promote “greater public understanding of the risks of tobacco.” As a result, research on consumer perceptions has the potential to shape the design and renewal of health warnings and to determine what, if any, information on product constituents should appear on packages. Research on consumer perceptions of existing and novel tobacco products will also be critical to help identify potentially misleading information that should be restricted under the Act. Conclusion: Packaging and labeling regulations required under the Act will bring the United States in line with international standards. There is an immediate need for research to evaluate these measures to guide future regulatory action. PMID:22039072
Design and fabrication of a foldable 3D silicon based package for solid state lighting applications
NASA Astrophysics Data System (ADS)
Sokolovskij, R.; Liu, P.; van Zeijl, H. W.; Mimoun, B.; Zhang, G. Q.
2015-05-01
Miniaturization of solid state lighting (SSL) luminaires as well as reduction of packaging and assembly costs are of prime interest for the SSL lighting industry. A novel silicon based LED package for lighting applications is presented in this paper. The proposed design consists of 5 rigid Si tiles connected by flexible polyimide hinges with embedded interconnects (ICs). Electrical, optical and thermal characteristics were taken into consideration during design. The fabrication process involved polyimide (PI) application and patterning, aluminium interconnect integration in the flexible hinge, LED reflector cavity formation and metalization followed by through wafer DRIE etching for chip formation and release. A method to connect chip front to backside without TSVs was also integrated into the process. Post-fabrication wafer level assembly included LED mounting and wirebond, phosphor-based colour conversion and silicone encapsulation. The package formation was finalized by vacuum assisted wrapping around an assembly structure to form a 3D geometry, which is beneficial for omnidirectional lighting. Bending tests were performed on the flexible ICs and optical performance at different temperatures was evaluated. It is suggested that 3D packages can be expanded to platforms for miniaturized luminaire applications by combining monolithic silicon integration and system-in-package (SiP) technologies.
NASA Technical Reports Server (NTRS)
Billica, Roger; Krupa, Debra T.; Stonestreet, Robert; Kizzee, Victor D.
1991-01-01
The purpose is to investigate and demonstrate equipment and techniques proposed for minor surgery on Space Station Freedom (SSF). The objectives are: (1) to test and evaluate methods of surgical instrument packaging and deployment; (2) to test and evaluate methods of surgical site preparation and draping; (3) to evaluate techniques of sterile procedure and maintaining sterile field; (4) to evaluate methods of trash management during medical/surgical procedures; and (4) to gain experience in techniques for performing surgery in microgravity. A KC-135 parabolic flight test was performed on March 30, 1990 with the goal of investigating and demonstrating surgical equipment and techniques under consideration for use on SSF. The flight followed the standard 40 parabola profile with 20 to 25 seconds of near-zero gravity in each parabola.
Dror, David M; Panda, Pradeep; May, Christina; Majumdar, Atanu; Koren, Ruth
2014-01-01
Introduction This study deals with consensus by poor persons in the informal sector in rural India on the benefit-package of their community-based health insurance (CBHI). In this article we describe the process of involving rural poor in benefit-package design and assess the underlying reasons for choices they made and their ability to reach group consensus. Methods The benefit-package selection process entailed four steps: narrowing down the options by community representatives, plus three Choosing Healthplans All Together (CHAT) rounds conducted among female members of self-help groups. We use mixed-methods and four sources of data: baseline study, CHAT exercises, in-depth interviews, and evaluation questionnaires. We define consensus as a community resolution reached by discussion, considering all opinions, and to which everyone agrees. We use the coefficient of unalikeability to express consensus quantitatively (as variability of categorical variables) rather than just categorically (as a binomial Yes/No). Findings The coefficient of unalikeability decreased consistently over consecutive CHAT rounds, reaching zero (ie, 100% consensus) in two locations, and confirmed gradual adoption of consensus. Evaluation interviews revealed that the wish to be part of a consensus was dominant in all locations. The in-depth interviews indicated that people enjoyed the participatory deliberations, were satisfied with the selection, and that group decisions reflected a consensus rather than majority. Moreover, evidence suggests that pre-selectors and communities aimed to enhance the likelihood that many households would benefit from CBHI. Conclusion The voluntary and contributory CBHI relies on an engaging experience with others to validate perceived priorities of the target group. The strongest motive for choice was the wish to join a consensus (more than price or package-composition) and the intention that many members should benefit. The degree of consensus improved with iterative CHAT rounds. Harnessing group consensus requires catalytic intervention, as the process is not spontaneous. PMID:25120378
SuperLab LT: Evaluation and Uses in Teaching Experimental Psychology
ERIC Educational Resources Information Center
Ragozzine, Frank
2002-01-01
I describe and evaluate SuperLab LT (Chase & Abboud, 1990), a software package that enables students to replicate classic experiments in cognitive psychology. I also discuss the package with respect to its uses in teaching an undergraduate course in Experimental Psychology. Although the package has minor flaws, SuperLab LT provides numerous…
CORM: An R Package Implementing the Clustering of Regression Models Method for Gene Clustering
Shi, Jiejun; Qin, Li-Xuan
2014-01-01
We report a new R package implementing the clustering of regression models (CORM) method for clustering genes using gene expression data and provide data examples illustrating each clustering function in the package. The CORM package is freely available at CRAN from http://cran.r-project.org. PMID:25452684
Komro, Kelli A; Flay, Brian R; Biglan, Anthony; Wagenaar, Alexander C
2016-03-01
Major advances in population health will not occur unless we translate existing knowledge into effective multicomponent interventions, implement and maintain these in communities, and develop rigorous translational research and evaluation methods to ensure continual improvement and sustainability. We discuss challenges and offer approaches to evaluation that are key for translational research stages 3 to 5 to advance optimized adoption, implementation, and maintenance of effective and replicable multicomponent strategies. The major challenges we discuss concern (a) multiple contexts of evaluation/research, (b) complexity of packages of interventions, and (c) phases of evaluation/research questions. We suggest multiple alternative research designs that maintain rigor but accommodate these challenges and highlight the need for measurement systems. Longitudinal data collection and a standardized continuous measurement system are fundamental to the evaluation and refinement of complex multicomponent interventions. To be useful to T3-T5 translational research efforts in neighborhoods and communities, such a system would include assessments of the reach, implementation, effects on immediate outcomes, and effects of the comprehensive intervention package on more distal health outcomes.
A normalization strategy for comparing tag count data
2012-01-01
Background High-throughput sequencing, such as ribonucleic acid sequencing (RNA-seq) and chromatin immunoprecipitation sequencing (ChIP-seq) analyses, enables various features of organisms to be compared through tag counts. Recent studies have demonstrated that the normalization step for RNA-seq data is critical for a more accurate subsequent analysis of differential gene expression. Development of a more robust normalization method is desirable for identifying the true difference in tag count data. Results We describe a strategy for normalizing tag count data, focusing on RNA-seq. The key concept is to remove data assigned as potential differentially expressed genes (DEGs) before calculating the normalization factor. Several R packages for identifying DEGs are currently available, and each package uses its own normalization method and gene ranking algorithm. We compared a total of eight package combinations: four R packages (edgeR, DESeq, baySeq, and NBPSeq) with their default normalization settings and with our normalization strategy. Many synthetic datasets under various scenarios were evaluated on the basis of the area under the curve (AUC) as a measure for both sensitivity and specificity. We found that packages using our strategy in the data normalization step overall performed well. This result was also observed for a real experimental dataset. Conclusion Our results showed that the elimination of potential DEGs is essential for more accurate normalization of RNA-seq data. The concept of this normalization strategy can widely be applied to other types of tag count data and to microarray data. PMID:22475125
Morreale, Federico; Angelino, Donato; Pellegrini, Nicoletta
2018-04-25
Gluten-free (GF) products are consumed both by individuals with celiac disease and by an increasing number of people with no specific medical needs. Although the technological quality of GF products has been recently improved, their nutritional quality is still scarcely addressed. Moreover, the few published studies report conflicting results, mostly because the information from product nutrition facts is the only considered factor. The aim of the present study was to develop a score-based method for the nutritional evaluation of 134 packaged Italian GF bakery products and to compare it with that of 162 matched gluten-containing (GC) food items. The score included the information from the nutrition facts and the presence/absence of some nutritionally relevant components in the ingredients list. Results indicated an overall low nutritional quality of the considered GF bakery products. Additionally, with the sole exception of GF bread substitutes, there was no difference in nutritional quality between GF and equivalent GC bakery products. Future research and development of GF bakery products may take advantage of this scoring method, as it may represent an easy approach to evaluate their nutritional quality. The present findings do not justify the consumption of packaged GF bakery products by people without any specific medical needs.
High resolution ultrasonic spectroscopy system for nondestructive evaluation
NASA Technical Reports Server (NTRS)
Chen, C. H.
1991-01-01
With increased demand for high resolution ultrasonic evaluation, computer based systems or work stations become essential. The ultrasonic spectroscopy method of nondestructive evaluation (NDE) was used to develop a high resolution ultrasonic inspection system supported by modern signal processing, pattern recognition, and neural network technologies. The basic system which was completed consists of a 386/20 MHz PC (IBM AT compatible), a pulser/receiver, a digital oscilloscope with serial and parallel communications to the computer, an immersion tank with motor control of X-Y axis movement, and the supporting software package, IUNDE, for interactive ultrasonic evaluation. Although the hardware components are commercially available, the software development is entirely original. By integrating signal processing, pattern recognition, maximum entropy spectral analysis, and artificial neural network functions into the system, many NDE tasks can be performed. The high resolution graphics capability provides visualization of complex NDE problems. The phase 3 efforts involve intensive marketing of the software package and collaborative work with industrial sectors.
ERIC Educational Resources Information Center
Northwest Regional Educational Lab., Portland, OR.
This document consists of 80 microcomputer software package evaluations prepared by the MicroSIFT (Microcomputer Software and Information for Teachers) Clearinghouse at the Northwest Regional Education Laboratory. Set 15 consists of 27 packages; set 16 consists of 53 packages. Each software review lists producer, time and place of evaluation,…
PB-AM: An open-source, fully analytical linear poisson-boltzmann solver
DOE Office of Scientific and Technical Information (OSTI.GOV)
Felberg, Lisa E.; Brookes, David H.; Yap, Eng-Hui
2016-11-02
We present the open source distributed software package Poisson-Boltzmann Analytical Method (PB-AM), a fully analytical solution to the linearized Poisson Boltzmann equation. The PB-AM software package includes the generation of outputs files appropriate for visualization using VMD, a Brownian dynamics scheme that uses periodic boundary conditions to simulate dynamics, the ability to specify docking criteria, and offers two different kinetics schemes to evaluate biomolecular association rate constants. Given that PB-AM defines mutual polarization completely and accurately, it can be refactored as a many-body expansion to explore 2- and 3-body polarization. Additionally, the software has been integrated into the Adaptive Poisson-Boltzmannmore » Solver (APBS) software package to make it more accessible to a larger group of scientists, educators and students that are more familiar with the APBS framework.« less
Package-X 2.0: A Mathematica package for the analytic calculation of one-loop integrals
NASA Astrophysics Data System (ADS)
Patel, Hiren H.
2017-09-01
This article summarizes new features and enhancements of the first major update of Package-X. Package-X 2.0 can now generate analytic expressions for arbitrarily high rank dimensionally regulated tensor integrals with up to four distinct propagators, each with arbitrary integer weight, near an arbitrary even number of spacetime dimensions, giving UV divergent, IR divergent, and finite parts at (almost) any real-valued kinematic point. Additionally, it can generate multivariable Taylor series expansions of these integrals around any non-singular kinematic point to arbitrary order. All special functions and abbreviations output by Package-X 2.0 support Mathematica's arbitrary precision evaluation capabilities to deal with issues of numerical stability. Finally, tensor algebraic routines of Package-X have been polished and extended to support open fermion chains both on and off shell. The documentation (equivalent to over 100 printed pages) is accessed through Mathematica's Wolfram Documentation Center and contains information on all Package-X symbols, with over 300 basic usage examples, 3 project-scale tutorials, and instructions on linking to FEYNCALC and LOOPTOOLS. Program files doi:http://dx.doi.org/10.17632/yfkwrd4d5t.1 Licensing provisions: CC by 4.0 Programming language: Mathematica (Wolfram Language) Journal reference of previous version: H. H. Patel, Comput. Phys. Commun 197, 276 (2015) Does the new version supersede the previous version?: Yes Summary of revisions: Extension to four point one-loop integrals with higher powers of denominator factors, separate extraction of UV and IR divergent parts, testing for power IR divergences, construction of Taylor series expansions of one-loop integrals, numerical evaluation with arbitrary precision arithmetic, manipulation of fermion chains, improved tensor algebraic routines, and much expanded documentation. Nature of problem: Analytic calculation of one-loop integrals in relativistic quantum field theory. Solution method: Passarino-Veltman reduction formula, Denner-Dittmaier reduction formulae, and additional algorithms described in the manuscript. Restrictions: One-loop integrals are limited to those involving no more than four denominator factors.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., packaged terminal air conditioners, and packaged terminal heat pumps. 431.96 Section 431.96 Energy... EQUIPMENT Commercial Air Conditioners and Heat Pumps Test Procedures § 431.96 Uniform test method for the... heating equipment, packaged terminal air conditioners, and packaged terminal heat pumps. (a) Scope. This...
Code of Federal Regulations, 2012 CFR
2012-01-01
..., packaged terminal air conditioners, and packaged terminal heat pumps. 431.96 Section 431.96 Energy... EQUIPMENT Commercial Air Conditioners and Heat Pumps Test Procedures § 431.96 Uniform test method for the... heating equipment, packaged terminal air conditioners, and packaged terminal heat pumps. (a) Scope. This...
Healthy choice?: Exploring how children evaluate the healthfulness of packaged foods.
Elliott, Charlene; Brierley, Meaghan
2012-11-06
Today's supermarket contains hundreds of packaged foods specifically targeted at children. Yet research has shown that children are confused by the various visual messages found on packaged food products. This study explores children's nutrition knowledge with regard to packaged food products, to uncover strengths and difficulties they have in evaluating the healthfulness of these foods. Focus groups were conducted with children (grades 1-6). Particular attention was paid to the ways children made use of what they know about nutrition when faced with the visual elements and appeals presented on food packaging. Children relied heavily on packages' written and visual aspects--including colour, images, spokes-characters, front-of-package claims--to assess the healthfulness of a food product. These elements interfere with children's ability to make healthy choices when it comes to packaged foods. Choosing healthy packaged foods is challenging for children due to competing sets of knowledge: one pertains to their understanding of visual, associational cues; the other, to translating their understanding of nutrition to packaged foods. Canada's Food Guide, along with the curriculum taught to Canadian children at schools, does not appear to provide children with the tools necessary to navigate a food environment dominated by packaged foods.
Ways To Evaluate Writing. Learning Package No. 47.
ERIC Educational Resources Information Center
Hyslop, Nancy, Comp.; Smith, Carl, Ed.
Originally developed as part of a project for the Department of Defense Schools (DoDDS) system, this learning package on ways to evaluate writing is designed for teachers who wish to upgrade or expand their teaching skills on their own. The package includes an overview of the project; a comprehensive search of the ERIC database; a lecture giving…
Applied Cognitive Task Analysis (ACTA) Methodology
1997-11-01
experienced based cognitive skills. The primary goal of this project was to develop streamlined methods of Cognitive Task Analysis that would fill this need...We have made important progression this direction. We have developed streamlined methods of Cognitive Task Analysis . Our evaluation study indicates...developed a CD-based stand alone instructional package, which will make the Applied Cognitive Task Analysis (ACTA) tools widely accessible. A survey of the
Solving Ordinary Differential Equations
NASA Technical Reports Server (NTRS)
Krogh, F. T.
1987-01-01
Initial-value ordinary differential equation solution via variable order Adams method (SIVA/DIVA) package is collection of subroutines for solution of nonstiff ordinary differential equations. There are versions for single-precision and double-precision arithmetic. Requires fewer evaluations of derivatives than other variable-order Adams predictor/ corrector methods. Option for direct integration of second-order equations makes integration of trajectory problems significantly more efficient. Written in FORTRAN 77.
NASA Technical Reports Server (NTRS)
McBride, Timothy M.
1995-01-01
A screening evaluation is being conducted to determine the performance of several glass fabric/vinyl ester composite material systems for use in primary General Aviation aircraft structures. In efforts to revitalize the General Aviation industry, the Integrated Design and Manufacturing Work Package for General Aviation Airframe and Propeller Structures is seeking to develop novel composite materials and low-cost manufacturing methods for lighter, safer and more affordable small aircraft. In support of this Work Package, this study is generating material properties for several glass fabric/rubber toughened vinyl ester composite systems and investigates the effect of environment on property retention. All laminates are made using the Seemann Composites Resin Infusion Molding Process (SCRIMP), a potential manufacturing method for the General Aviation industry.
Kohrt, B A; Burkey, M; Stuart, E A; Koirala, S
2015-01-01
Ethical, logistical, and funding approaches preclude conducting randomized control trials (RCTs) in some humanitarian crises. A lack of RCTs and other intervention research has contributed to a limited evidence-base for mental health and psychosocial support (MHPS) programs after disasters, war, and disease outbreaks. Propensity score methods (PSMs) are an alternative analysis technique with potential application for evaluating MHPS programs in humanitarian emergencies. PSMs were used to evaluate impacts of education reintegration packages (ERPs) and other (vocational or economic) reintegration packages (ORPs) v. no reintegration programs on mental health of child soldiers. Propensity scores were used to determine weighting of child soldiers in each of the three treatment arms. Multiple linear regression was used to estimate adjusted changes in symptom score severity on culturally validated measures of depression, post-traumatic stress disorder (PTSD), and functional impairment from baseline to 1-year follow-up. Among 258 Nepali child soldiers participating in reintegration programs, 54.7% completed ERP and 22.9% completed ORP. There was a non-significant reduction in depression by 0.59 (95% CI -1.97 to 0.70) for ERP and by 0.60 (95% CI -2.16 to 0.96) for ORP compared with no treatment. There were non-significant increases in PTSD (1.15, 95% CI -1.55 to 3.86) and functional impairment (0.91, 95% CI -0.31 to 2.14) associated with ERP and similar findings for ORP (PTSD: 0.66, 95% CI -2.24 to 3.57; functional impairment (1.05, 95% CI -0.71 to 2.80). In a humanitarian crisis in which a non-randomized intervention assignment protocol was employed, the statistical technique of PSMs addressed differences in covariate distribution between child soldiers who received different integration packages. Our analysis did not demonstrate significant changes in psychosocial outcomes for ERPs and ORPs. We suggest the use of PSMs in evaluating non-randomized interventions in humanitarian crises when non-randomized conditions are not utilized.
A case study of exploiting enterprise resource planning requirements
NASA Astrophysics Data System (ADS)
Niu, Nan; Jin, Mingzhou; Cheng, Jing-Ru C.
2011-05-01
The requirements engineering (RE) processes have become a key to conceptualising corporate-wide integrated solutions based on packaged enterprise resource planning (ERP) software. The RE literature has mainly focused on procuring the most suitable ERP package. Little is known about how an organisation exploits the chosen ERP RE model to frame the business application development. This article reports an exploratory case study of a key tenet of ERP RE adoption, namely that aligning business applications to the packaged RE model leads to integral practices and economic development. The case study analysed a series interrelated pilot projects developed for a business division of a large IT manufacturing and service company, using Oracle's appl1ication implementation method (AIM). The study indicated that AIM RE improved team collaboration and project management experience, but needed to make hidden assumptions explicit to support data visibility and integrity. Our study can direct researchers towards rigorous empirical evaluations of ERP RE adoption, collect experiences and lessons learned for practitioners, and help generate more effective and mature processes when exploiting ERP RE methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, D L
The US Department of Energy (DOE) has been conducting, through several of its operating contractors, an evaluation and testing program to qualify Type A radioactive material packagings per US Department of Transportation (DOT) Specification 7A (DOT-7A) of the Code of Federal Regulations (CFR), Title 49, Part 178 (49 CFR 178). This document summarizes the evaluation and testing performed for all of the packagings successfully qualified in this program. This document supersedes DOE Evaluation Document for DOT-7A Type A Packaging (Edling 1987), originally issued in 1987 by Monsanto Research Corporation Mound Laboratory (MLM), Miamisburg, Ohio, for the Department of Energy, Securitymore » Evaluation Program (I)P-4. Mound Laboratory issued four revisions to the document between November 1988 and December 1989. In September 1989, the program was transferred to Westinghouse Hanford Company (Westinghouse Hanford) in Richland, Washington. One additional revision was issued in March 1990 by Westinghouse Hanford. This revision reflects the earlier material and incorporates a number of changes. Evaluation and testing activities on 1208 three DOT-7A Program Dockets resulted in the qualification of three new packaging configurations, which are incorporated herein and summarized. This document presents approximately 300 different packagings that have been determined to meet the requirements for a DOT-7A, type A packaging per 49 CFR 178.350.« less
USDA-ARS?s Scientific Manuscript database
The yeast form (blastospore) of the dimorphic insect-pathogenic fungus Beauveria bassiana can be rapidly produced using liquid fermentation methods but is generally unable to survive rapid dehydration processes or storage under non-refrigerated conditions. In this study, we evaluated the influence o...
Computers in medical education 1: evaluation of a problem-orientated learning package.
Devitt, P; Palmer, E
1998-04-01
A computer-based learning package has been developed, aimed at expanding students' knowledge base, as well as improving data-handling abilities and clinical problem-solving skills. The program was evaluated by monitoring its use by students, canvassing users' opinions and measuring its effectiveness as a learning tool compared to tutorials on the same material. Evaluation was undertaken using three methods: initially, by a questionnaire on computers as a learning tool and the applicability of the content: second, through monitoring by the computer of student use, decisions and performance; finally, through pre- and post-test assessment of fifth-year students who either used a computer package or attended a tutorial on equivalent material. Most students provided positive comments on the learning material and expressed a willingness to see computer-aided learning (CAL) introduced into the curriculum. Over a 3-month period, 26 modules in the program were used on 1246 occasions. Objective measurement showed a significant gain in knowledge, data handling and problem-solving skills. Computer-aided learning is a valuable learning resource that deserves better attention in medical education. When used appropriately, the computer can be an effective learning resource, not only for the delivery of knowledge. but also to help students develop their problem-solving skills.
eSBMTools 1.0: enhanced native structure-based modeling tools.
Lutz, Benjamin; Sinner, Claude; Heuermann, Geertje; Verma, Abhinav; Schug, Alexander
2013-11-01
Molecular dynamics simulations provide detailed insights into the structure and function of biomolecular systems. Thus, they complement experimental measurements by giving access to experimentally inaccessible regimes. Among the different molecular dynamics techniques, native structure-based models (SBMs) are based on energy landscape theory and the principle of minimal frustration. Typically used in protein and RNA folding simulations, they coarse-grain the biomolecular system and/or simplify the Hamiltonian resulting in modest computational requirements while achieving high agreement with experimental data. eSBMTools streamlines running and evaluating SBM in a comprehensive package and offers high flexibility in adding experimental- or bioinformatics-derived restraints. We present a software package that allows setting up, modifying and evaluating SBM for both RNA and proteins. The implemented workflows include predicting protein complexes based on bioinformatics-derived inter-protein contact information, a standardized setup of protein folding simulations based on the common PDB format, calculating reaction coordinates and evaluating the simulation by free-energy calculations with weighted histogram analysis method or by phi-values. The modules interface with the molecular dynamics simulation program GROMACS. The package is open source and written in architecture-independent Python2. http://sourceforge.net/projects/esbmtools/. alexander.schug@kit.edu. Supplementary data are available at Bioinformatics online.
Method of fabricating a microelectronic device package with an integral window
Peterson, Kenneth A.; Watson, Robert D.
2003-01-01
A method of fabricating a microelectronic device package with an integral window for providing optical access through an aperture in the package. The package is made of a multilayered insulating material, e.g., a low-temperature cofired ceramic (LTCC) or high-temperature cofired ceramic (HTCC). The window is inserted in-between personalized layers of ceramic green tape during stackup and registration. Then, during baking and firing, the integral window is simultaneously bonded to the sintered ceramic layers of the densified package. Next, the microelectronic device is flip-chip bonded to cofired thick-film metallized traces on the package, where the light-sensitive side is optically accessible through the window. Finally, a cover lid is attached to the opposite side of the package. The result is a compact, low-profile package, flip-chip bonded, hermetically-sealed package having an integral window.
Design Optimization Toolkit: Users' Manual
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aguilo Valentin, Miguel Alejandro
The Design Optimization Toolkit (DOTk) is a stand-alone C++ software package intended to solve complex design optimization problems. DOTk software package provides a range of solution methods that are suited for gradient/nongradient-based optimization, large scale constrained optimization, and topology optimization. DOTk was design to have a flexible user interface to allow easy access to DOTk solution methods from external engineering software packages. This inherent flexibility makes DOTk barely intrusive to other engineering software packages. As part of this inherent flexibility, DOTk software package provides an easy-to-use MATLAB interface that enables users to call DOTk solution methods directly from the MATLABmore » command window.« less
Environmental assessment of packaging: Sense and sensibility
NASA Astrophysics Data System (ADS)
Kooijman, Jan M.
1993-09-01
The functions of packaging are derived from product requirements, thus for insight into the environmental effects of packaging the actual combination of product and package has to be evaluated along the production and distribution system. This extension to all related environmental aspects adds realism to the environmental analysis and provides guidance for design while preventing a too detailed investigation of parts of the production system. This approach is contrary to current environmental studies where packaging is always treated as an independent object, neglecting the more important environmental effects of the product that are influenced by packaging. The general analysis and quantification stages for this approach are described, and the currently available methods for the assessment of environmental effects are reviewed. To limit the workload involved in an environmental assessment, a step-by-step analysis and the use of feedback is recommended. First the dominant environmental effects of a particular product and its production and distribution are estimated. Then, on the basis of these preliminary results, the appropriate system boundaries are chosen and the need for further or more detailed environmental analysis is determined. For typical food and drink applications, the effect of different system boundaries on the outcome of environmental assessments and the advantage of the step-by-step analysis of the food supply system is shown. It appears that, depending on the consumer group, different advice for reduction of environmental effects has to be given. Furthermore, because of interrelated environmental effects of the food supply system, the continuing quest for more detailed and accurate analysis of the package components is not necessary for improved management of the environmental effects of packaging.
Evaluating the Progress of the School Reading Program. Learning Package No. 17.
ERIC Educational Resources Information Center
Nelson, Carol; Smith, Carl, Comp.
Originally developed for the Department of Defense Schools (DoDDS) system, this learning package on evaluating the progress of the school reading program is designed for teachers who wish to upgrade or expand their teaching skills on their own. The package includes a comprehensive search of the ERIC database; a lecture giving an overview on the…
ERIC Educational Resources Information Center
Pennington, Robert C.; Rockhold, Jessica
2018-01-01
In the current study, we investigated the effects of an instructional package on the construction of sentences writing by four children ages 6-9, with autism spectrum disorder (ASD). We employed a multiple probe across behaviors design to evaluate the efficacy of the intervention package and also conducted probes to assess generalization and…
Naming, labeling, and packaging of pharmaceuticals.
Kenagy, J W; Stein, G C
2001-11-01
The problem of medical errors associated with the naming, labeling, and packaging of pharmaceuticals is discussed. Sound-alike and look-alike drug names and packages can lead pharmacists and nurses to unintended interchanges of drugs that can result in patient injury or death. The existing medication-use system is flawed because its safety depends on human perfection. Simplicity, standardization, differentiation, lack of duplication, and unambiguous communication are human factors concepts that are relevant to the medication-use process. These principles have often been ignored in drug naming, labeling, and packaging. Instead, current methods are based on long-standing commercial considerations and bureaucratic procedures. The process for naming a marketable drug is lengthy and complex and involves submission of a new chemical entity and patent application, generic naming, brand naming, FDA review, and final approval. Drug companies seek the fastest possible approval and may believe that the incremental benefit of human factors evaluation is small. "Trade dress" is the concept that underlies labeling and packaging issues for the drug industry. Drug companies are resistant to changing trade dress and brand names. Although a variety of private-sector organizations have called for reforms in drug naming, labeling, and packaging standards have been proposed, the problem remains. Drug names, labels, and packages are not selected and designed in accordance with human factors principles. FDA standards do not require application of these principles, the drug industry has struggled with change, and private-sector initiatives have had only limited success.
NASA Astrophysics Data System (ADS)
Suwanti, D.; Utami, R.; Kawiji; Praseptiangga, D.; Khasanah, L. U.
2018-01-01
Papaya is one of the export commodities that contain high vitamin C but having short shelf-life. One method that use to extend the shelf-life and maintain the quality of papaya is packaging. The aim of this study was to investigate the effect of the packaging methods (paper, active paper and edible coating) on the characteristics of papaya MJ9 (weight loss, firmness, total soluble solid (TSS), Total Titratable Acid (TTA), pH, vitamin C and total mold and yeast). The packaging methods were control (F1), wrapping paper (F2), wrapping active paper (F3), combination of edible coating and wrapping paper (F4), and combination of edible coating and wrapping active paper (F5). The result showed that paper packaging, edible coating and active paper packaging significantly affected the weight loss, firmness, total soluble solid, total titratable acids, pH, vitamin C, and total mold and yeast of papaya. The weight loss, total soluble solid and pH of packaged papaya was lower than that of control sample, however, the value of firmness and total titratable acid was higher than that of the control sample. Packaging can inhibit the increase of weight loss, total soluble solids and pH, and the decrease of firmness, total titratable acid, vitamin C and total mold and yeast. Based on the papaya characteristics, the selected packaging method was the combination of edible coating and wrapping active paper.
An Analysis of an R&D Program Selection Process at the Aeronautical Systems Division.
1980-09-01
Without the help of the Defense Wide Management and Support panel members, this research effort would have been impossible. They provided valuable personal ...decision packages. Next, the DWMS panel members were interviewed in order to obtain their personal interpretation of the evaluation cri- teria used by...packages (McCandless, 1978:46). The state of Georgia had over 11,000 packages to evaluate, and it would be impossible for one person to evaluate all the
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kung, F.; Deru, M.; Bonnema, E.
2013-10-01
Few third-party guidance documents or tools are available for evaluating thermal energy storage (TES) integrated with packaged air conditioning (AC), as this type of TES is relatively new compared to TES integrated with chillers or hot water systems. To address this gap, researchers at the National Renewable Energy Laboratory conducted a project to improve the ability of potential technology adopters to evaluate TES technologies. Major project outcomes included: development of an evaluation framework to describe key metrics, methodologies, and issues to consider when assessing the performance of TES systems integrated with packaged AC; application of multiple concepts from the evaluationmore » framework to analyze performance data from four demonstration sites; and production of a new simulation capability that enables modeling of TES integrated with packaged AC in EnergyPlus. This report includes the evaluation framework and analysis results from the project.« less
THE NEW ENLISTED EVALUATION SYSTEM: DID THE AIR FORCE GET IT CORRECT THIS TIME
2015-10-01
faced a two-fold problem - excessive manning promoted through the war along with an increased use of contractors for maintenance and support. This...concept to standardize board promotion methods .38 A three-judge panel scored each package using a 10-point scale on ½-point increments. If the three...rounding methods were changed to remove inequities. The original methods rounded up or down to the nearest whole percentage point, but this change
Sanches-Silva, A; Ribeiro, T; Albuquerque, T G; Paseiro, P; Sendón, R; de Quirós, A Bernaldo; López-Cervantes, J; Sánchez-Machado, D I; Soto Valdez, H; Angulo, I; Aurrekoetxea, G P; Costa, H S
2013-06-01
Nowadays, there is increasing interest in natural antioxidants from food by-products. Astaxanthin is a potent antioxidant and one of the major carotenoids in crustaceans and salmonids. An ultra-high pressure liquid chromatographic method was developed and validated for the determination of astaxanthin in shrimp by-products, and its migration from new packaging materials to food simulants was also studied. The method uses an UPLC® BEH guard-column (2.1 × 5 mm, 1.7 µm particle size) and an UPLC® BEH analytical column (2.1 × 50 mm, 1.7 µm particle size). Chromatographic separation was achieved using a programmed gradient mobile phase consisting of (A) acetonitrile-methanol (containing 0.05 m ammonium acetate)-dichloromethane (75:20:5, v/v/v) and (B) ultrapure water. This method was evaluated with respect to validation parameters such as linearity, precision, limit of detection, limit of quantification and recovery. Low-density polyethylene films were prepared with different amounts of the lipid fraction of fermented shrimp waste by extrusion, and migration was evaluated into food simulants (isooctane and ethanol 95%, v/v). Migration was not detected under the tested conditions. Copyright © 2012 John Wiley & Sons, Ltd.
Food product design: emerging evidence for food policy.
Al-Hamdani, Mohammed; Smith, Steven
2017-03-01
The research on the impact of specific brand elements such as food descriptors and package colors is underexplored. We tested whether a "light" color and a "low-calorie" descriptor on food packages gain favorable consumer perception ratings as compared with regular packages. Our online experiment recruited 406 adults in a 3 (product type: Chips versus Juice versus Yoghurt) × 2 (descriptor type: regular versus low-calorie) × 2 (color type: regular versus light) mixed design. Dependent variables were sensory (evaluations of the product's nutritional value and quality), product-based (evaluations of the product's physical appeal), and consumer-based (evaluations of the potential consumers of the product) scales. "Low-calorie" descriptors were found to increase sensory ratings as compared with regular descriptors and light-colored packages received higher product-based ratings as compared with their regular-colored counterparts. Food package color and descriptors present a promising venue for understanding preventative measures against obesity.[Formula: see text].
Association of Time between Surgery and Adjuvant Therapy with Survival in Oral Cavity Cancer.
Chen, Michelle M; Harris, Jeremy P; Orosco, Ryan K; Sirjani, Davud; Hara, Wendy; Divi, Vasu
2018-06-01
Objective The National Cancer Center Network recommends starting radiation therapy within 6 weeks after surgery for oral cavity squamous cell carcinoma (OCSCC), but there is limited evidence of the importance of the total time from surgery to completion of radiation therapy (package time). We set out to determine if there was an association between package time and survival in OCSCC and to evaluate the impact of treatment location on outcomes. Study Design Retrospective cohort study. Setting Tertiary academic medical center. Subjects and Methods We reviewed the records of patients with OCSCC who completed postoperative radiation therapy at an academic medical center from 2008 to 2016. The primary endpoints were overall survival and recurrence-free survival. Statistical analysis included χ 2 tests and Cox proportional hazards regressions. Results We identified 132 patients with an average package time of 12.6 weeks. On multivariate analysis, package time >11 weeks was independently associated with decreased overall survival (hazard ratio, 6.68; 95% CI, 1.42-31.44) and recurrence-free survival (hazard ratio, 2.94; 95% CI, 1.20-7.18). Patients who received radiation therapy at outside facilities were more likely to have treatment delays (90.2% vs 62.9%, P = .001). Conclusions Prolonged package times are associated with decreased overall and recurrence-free survival among patients with OCSCC. Patients who received radiation therapy at outside facilities are more likely to have prolonged package times.
USDA-ARS?s Scientific Manuscript database
Larvae of the Indian meal moth, Plodia interpunctella (Hübner), can invade or penetrate packaging materials and infest food products. Energy bars with three polypropylene packaging types were challenged with eggs (first instars), third, and fifth instars of P. interpunctella to determine package res...
PB-AM: An open-source, fully analytical linear poisson-boltzmann solver.
Felberg, Lisa E; Brookes, David H; Yap, Eng-Hui; Jurrus, Elizabeth; Baker, Nathan A; Head-Gordon, Teresa
2017-06-05
We present the open source distributed software package Poisson-Boltzmann Analytical Method (PB-AM), a fully analytical solution to the linearized PB equation, for molecules represented as non-overlapping spherical cavities. The PB-AM software package includes the generation of outputs files appropriate for visualization using visual molecular dynamics, a Brownian dynamics scheme that uses periodic boundary conditions to simulate dynamics, the ability to specify docking criteria, and offers two different kinetics schemes to evaluate biomolecular association rate constants. Given that PB-AM defines mutual polarization completely and accurately, it can be refactored as a many-body expansion to explore 2- and 3-body polarization. Additionally, the software has been integrated into the Adaptive Poisson-Boltzmann Solver (APBS) software package to make it more accessible to a larger group of scientists, educators, and students that are more familiar with the APBS framework. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Healy, Sue; Israel, Fiona; Charles, Margaret A; Reymond, Liz
2013-06-01
Palliative care services strive to support people to live and die well in their chosen environment, with optimal symptom control and a pattern of care supportive of laycarers. The likelihood of patients remaining at home often depends upon laycarers, who may be required to manage subcutaneous medications. This study reports the development, trial and evaluation of a package that teaches laycarers to manage subcutaneous medications used for symptom control in home-based patients. The package was developed by palliative care stakeholders and comprises an educational session, delivered by nurses, and a range of demonstrative, audiovisual and written resources. The package was trialled across 24 sites and was evaluated by 76 laycarers (pre- and post-use) and 53 nurses (at study completion). Outcomes of primary interest were perceived global usefulness of the package and rated relevance of components. Laycarers and nurses rated the usefulness and relevance of the package highly - all means were above 5 on a 7-point scale. Also, laycarers were invited to comment on the package, and three focus groups for 26 nurses explored post hoc issues following package implementation. In terms of the palliative patient's illness trajectory, consensus was that the time for package introduction depended upon each particular clinical situation and laycarer. Nursing opinion was divided concerning whether it is safe and appropriate for laycarers to manage subcutaneous injections. Nevertheless, this study demonstrates that the package supports laycarers to manage subcutaneous medications. This has important implications for families, services and health-care systems.
Spanos, Dimitrios; Christensen, Mette; Tørngren, Mari Ann; Baron, Caroline P
2016-03-01
The storage conditions of fresh meat are known to impact its colour and microbial shelf life. In the present study, visible spectroscopy was evaluated as a method to assess meat storage conditions and its optimisation. Fresh pork steaks (longissimus thoracis et lumborum and semimembranosus) were placed in modified atmosphere packaging using gas mixtures containing 0, 40, 50, and 80% oxygen, and stored with or without light for up to 9days. Principal component analysis of visible reflectance spectra (400-700nm) showed that the colour of the different meat cuts was affected by presence of oxygen, illumination, and storage time. Differences in the oxygen levels did not contribute to the observed variance. Predictive models based on partial least squares regression-discriminant analysis exhibited high potency in the classification of the storage parameters of meat cuts packaged in modified atmosphere. The study demonstrates the applicability of visible spectroscopy as a tool to assess the storage conditions of meat cuts packaged in modified atmosphere. Copyright © 2015 Elsevier Ltd. All rights reserved.
2012 drug packaging review: many dangerous, reportable flaws.
2013-05-01
Drug packaging plays an important role in protecting and providing information to patients. The packaging examined by Prescrire in 2012, on the whole, still fails to perform all of these functions effectively. Two issues are especially worrisome. First, packaging too often poses a danger to children. In addition, too many patient leaflets provide incomplete information about adverse effects, thus failing to properly protect the most vulnerable patients. Yet, the method Prescrire used to analyse drug packaging shows that it is not difficult to detect and anticipate risks. It is up to healthcare professionals to take advantage of the method, to protect patients from, and report, dangerous packaging.
R package to estimate intracluster correlation coefficient with confidence interval for binary data.
Chakraborty, Hrishikesh; Hossain, Akhtar
2018-03-01
The Intracluster Correlation Coefficient (ICC) is a major parameter of interest in cluster randomized trials that measures the degree to which responses within the same cluster are correlated. There are several types of ICC estimators and its confidence intervals (CI) suggested in the literature for binary data. Studies have compared relative weaknesses and advantages of ICC estimators as well as its CI for binary data and suggested situations where one is advantageous in practical research. The commonly used statistical computing systems currently facilitate estimation of only a very few variants of ICC and its CI. To address the limitations of current statistical packages, we developed an R package, ICCbin, to facilitate estimating ICC and its CI for binary responses using different methods. The ICCbin package is designed to provide estimates of ICC in 16 different ways including analysis of variance methods, moments based estimation, direct probabilistic methods, correlation based estimation, and resampling method. CI of ICC is estimated using 5 different methods. It also generates cluster binary data using exchangeable correlation structure. ICCbin package provides two functions for users. The function rcbin() generates cluster binary data and the function iccbin() estimates ICC and it's CI. The users can choose appropriate ICC and its CI estimate from the wide selection of estimates from the outputs. The R package ICCbin presents very flexible and easy to use ways to generate cluster binary data and to estimate ICC and it's CI for binary response using different methods. The package ICCbin is freely available for use with R from the CRAN repository (https://cran.r-project.org/package=ICCbin). We believe that this package can be a very useful tool for researchers to design cluster randomized trials with binary outcome. Copyright © 2017 Elsevier B.V. All rights reserved.
Combining multiple tools outperforms individual methods in gene set enrichment analyses.
Alhamdoosh, Monther; Ng, Milica; Wilson, Nicholas J; Sheridan, Julie M; Huynh, Huy; Wilson, Michael J; Ritchie, Matthew E
2017-02-01
Gene set enrichment (GSE) analysis allows researchers to efficiently extract biological insight from long lists of differentially expressed genes by interrogating them at a systems level. In recent years, there has been a proliferation of GSE analysis methods and hence it has become increasingly difficult for researchers to select an optimal GSE tool based on their particular dataset. Moreover, the majority of GSE analysis methods do not allow researchers to simultaneously compare gene set level results between multiple experimental conditions. The ensemble of genes set enrichment analyses (EGSEA) is a method developed for RNA-sequencing data that combines results from twelve algorithms and calculates collective gene set scores to improve the biological relevance of the highest ranked gene sets. EGSEA's gene set database contains around 25 000 gene sets from sixteen collections. It has multiple visualization capabilities that allow researchers to view gene sets at various levels of granularity. EGSEA has been tested on simulated data and on a number of human and mouse datasets and, based on biologists' feedback, consistently outperforms the individual tools that have been combined. Our evaluation demonstrates the superiority of the ensemble approach for GSE analysis, and its utility to effectively and efficiently extrapolate biological functions and potential involvement in disease processes from lists of differentially regulated genes. EGSEA is available as an R package at http://www.bioconductor.org/packages/EGSEA/ . The gene sets collections are available in the R package EGSEAdata from http://www.bioconductor.org/packages/EGSEAdata/ . monther.alhamdoosh@csl.com.au mritchie@wehi.edu.au. Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press.
de Hoop, Bartjan; Gietema, Hester; van Ginneken, Bram; Zanen, Pieter; Groenewegen, Gerard; Prokop, Mathias
2009-04-01
We compared interexamination variability of CT lung nodule volumetry with six currently available semi-automated software packages to determine the minimum change needed to detect the growth of solid lung nodules. We had ethics committee approval. To simulate a follow-up examination with zero growth, we performed two low-dose unenhanced CT scans in 20 patients referred for pulmonary metastases. Between examinations, patients got off and on the table. Volumes of all pulmonary nodules were determined on both examinations using six nodule evaluation software packages. Variability (upper limit of the 95% confidence interval of the Bland-Altman plot) was calculated for nodules for which segmentation was visually rated as adequate. We evaluated 214 nodules (mean diameter 10.9 mm, range 3.3 mm-30.0 mm). Software packages provided adequate segmentation in 71% to 86% of nodules (p < 0.001). In case of adequate segmentation, variability in volumetry between scans ranged from 16.4% to 22.3% for the various software packages. Variability with five to six software packages was significantly less for nodules >or=8 mm in diameter (range 12.9%-17.1%) than for nodules <8 mm (range 18.5%-25.6%). Segmented volumes of each package were compared to each of the other packages. Systematic volume differences were detected in 11/15 comparisons. This hampers comparison of nodule volumes between software packages.
Propagation of coherent light pulses with PHASE
NASA Astrophysics Data System (ADS)
Bahrdt, J.; Flechsig, U.; Grizzoli, W.; Siewert, F.
2014-09-01
The current status of the software package PHASE for the propagation of coherent light pulses along a synchrotron radiation beamline is presented. PHASE is based on an asymptotic expansion of the Fresnel-Kirchhoff integral (stationary phase approximation) which is usually truncated at the 2nd order. The limits of this approximation as well as possible extensions to higher orders are discussed. The accuracy is benchmarked against a direct integration of the Fresnel-Kirchhoff integral. Long range slope errors of optical elements can be included by means of 8th order polynomials in the optical element coordinates w and l. Only recently, a method for the description of short range slope errors has been implemented. The accuracy of this method is evaluated and examples for realistic slope errors are given. PHASE can be run either from a built-in graphical user interface or from any script language. The latter method provides substantial flexibility. Optical elements including apertures can be combined. Complete wave packages can be propagated, as well. Fourier propagators are included in the package, thus, the user may choose between a variety of propagators. Several means to speed up the computation time were tested - among them are the parallelization in a multi core environment and the parallelization on a cluster.
Approximated adjusted fractional Bayes factors: A general method for testing informative hypotheses.
Gu, Xin; Mulder, Joris; Hoijtink, Herbert
2018-05-01
Informative hypotheses are increasingly being used in psychological sciences because they adequately capture researchers' theories and expectations. In the Bayesian framework, the evaluation of informative hypotheses often makes use of default Bayes factors such as the fractional Bayes factor. This paper approximates and adjusts the fractional Bayes factor such that it can be used to evaluate informative hypotheses in general statistical models. In the fractional Bayes factor a fraction parameter must be specified which controls the amount of information in the data used for specifying an implicit prior. The remaining fraction is used for testing the informative hypotheses. We discuss different choices of this parameter and present a scheme for setting it. Furthermore, a software package is described which computes the approximated adjusted fractional Bayes factor. Using this software package, psychological researchers can evaluate informative hypotheses by means of Bayes factors in an easy manner. Two empirical examples are used to illustrate the procedure. © 2017 The British Psychological Society.
Are Written Instructions Enough? Efficacy of Male Condom Packaging Leaflets among College Students
ERIC Educational Resources Information Center
Lindemann, Dana F.; Harbke, Colin R.
2013-01-01
Objective: To evaluate whether or not written condom use instructions successfully inform correct condom use skills. Design: Between-subjects, two-group design. Setting: Public university located in rural Midwestern region of the United States. Method: Participants were randomly assigned to either a control condition (read physical exercise…
Minh, Hoang Van; Chung, Le Hong; Giang, Kim Bao; Duc, Duong Minh; Hinh, Nguyen Duc; Mai, Vu Quynh; Cuong, Nguyen Manh; Manh, Pham Duc; Duc, Ha Anh; Yang, Jui-Chen
2016-01-01
Two years after implementation of the graphic health warning intervention in Vietnam, it is very important to evaluate the intervention's potential impact. The objective of this paper was to predict effects of graphic health warnings on cigarette packages, particularly in reducing cigarette demand and smoking-associated deaths in Vietnam. In this study, a discrete choice experiment (DCE) method was used to evaluate the potential impact of graphic tobacco health warnings on smoking demand. To predict the impact of GHWs on reducing premature deaths associated with smoking, we constructed different static models. We adapted the method developed by University of Toronto, Canada and found that GHWs had statistically significant impact on reducing cigarette demand (up to 10.1% through images of lung damage), resulting in an overall decrease of smoking prevalence in Vietnam. We also found that between 428,417- 646,098 premature deaths would be prevented as a result of the GHW intervention. The potential impact of the GHW labels on reducing premature smoking-associated deaths in Vietnam were shown to be stronger among lower socio-economic groups.
Kim, Yoonsang; Choi, Young-Ku; Emery, Sherry
2013-08-01
Several statistical packages are capable of estimating generalized linear mixed models and these packages provide one or more of three estimation methods: penalized quasi-likelihood, Laplace, and Gauss-Hermite. Many studies have investigated these methods' performance for the mixed-effects logistic regression model. However, the authors focused on models with one or two random effects and assumed a simple covariance structure between them, which may not be realistic. When there are multiple correlated random effects in a model, the computation becomes intensive, and often an algorithm fails to converge. Moreover, in our analysis of smoking status and exposure to anti-tobacco advertisements, we have observed that when a model included multiple random effects, parameter estimates varied considerably from one statistical package to another even when using the same estimation method. This article presents a comprehensive review of the advantages and disadvantages of each estimation method. In addition, we compare the performances of the three methods across statistical packages via simulation, which involves two- and three-level logistic regression models with at least three correlated random effects. We apply our findings to a real dataset. Our results suggest that two packages-SAS GLIMMIX Laplace and SuperMix Gaussian quadrature-perform well in terms of accuracy, precision, convergence rates, and computing speed. We also discuss the strengths and weaknesses of the two packages in regard to sample sizes.
Lee, Sun-Young; Baek, Seung-Youb
2008-06-01
Escherichia coli O157:H7 contaminated spinach has recently caused several outbreaks of human illness in the USA and Canada. However, to date, there has been no study demonstrating an effective way to eliminate E. coli O157:H7 in spinach. Therefore, this study was conducted to investigate the effect of chemical sanitizers alone or in combination with packaging methods such as vacuum and modified atmosphere packaging (MAP) on inactivating E. coli O157:H7 in spinach during storage time. Spinach inoculated with E. coli O157:H7 was packaged in four different methods (air, vacuum, N(2) gas, and CO(2) gas packaging) following treatment with water, 100 ppm chlorine dioxide, or 100 ppm sodium hypochlorite for 5 min at room temperature and stored at 7+/-2 degrees C. Treatment with water did not significantly reduce levels of E. coli O157:H7 in spinach. However, treatment with chlorine dioxide and sodium hypochlorite significantly decreased levels of E. coli O157:H7 by 2.6 and 1.1 log(10)CFU/g, respectively. Levels of E. coli O157:H7 in samples packaged in air following treatments grew during storage time, whereas levels were maintained in samples packaged in other packaging methods (vacuum, N(2) gas, and CO(2) gas packaging). Therefore there were significant differences (about 3-4 log) of E. coli O157:H7 populations between samples packed in air and other packaging methods following treatment with chemical sanitizers after 7 days storage. These results suggest that the combination of treatment with chlorine dioxide and packaging methods such as vacuum and MAP may be useful for improving the microbial safety of spinach against E. coli O157:H7 during storage.
ERIC Educational Resources Information Center
Grable-Wallace, Lisa; And Others
1989-01-01
Evaluates 5 courseware packages covering the topics of simple harmonic motion, 7 packages for wave motion, and 10 packages for sound. Discusses the price range, sub-topics, program type, interaction, time, calculus required, graphics, and comments of each courseware. Selects several packages based on the criteria. (YP)
Business Telephone Etiquette. Comptetency Test Package. Office Occupations. Instructor's Guide.
ERIC Educational Resources Information Center
Hines, Donna
This competency test package, one of a series of test packages for office occupations education, contains a list of performance objectives: a sample, 50-point objective test; and several performance test activities. The package also includes complete directions for the student and the instructor, plus answer keys and a guide for evaluating the…
Mascarin, Gabriel Moura; Jackson, Mark A; Behle, Robert W; Kobori, Nilce N; Júnior, Ítalo Delalibera
2016-10-01
The yeast form (blastospore) of the dimorphic insect-pathogenic fungus Beauveria bassiana can be rapidly produced using liquid fermentation methods but is generally unable to survive rapid dehydration processes or storage under non-refrigerated conditions. In this study, we evaluated the influence of two convective drying methods, various modified atmosphere packaging systems, and storage temperatures on the desiccation tolerance, storage stability, and virulence of blastospores of B. bassiana ESALQ 1432. All blastospore formulations were dried to <5 % water content equivalent to aw < 0.3. The viability of B. bassiana blastospores after air drying and spray drying was greater than 80 %. Vacuum-packaged blastospores remained viable longer when stored at 4 °C compared with 28 °C with virtually no loss in viability over 9 months regardless the drying method. When both oxygen and moisture scavengers were added to sealed packages of dried blastospore formulations stored at 28 °C, viability was significantly prolonged for both air- and spray-dried blastospores. The addition of ascorbic acid during spray drying did not improve desiccation tolerance but enhanced cell stability (∼twofold higher half-life) when stored at 28 °C. After storage for 4 months at 28 °C, air-dried blastospores produced a lower LC80 and resulted in higher mortality to whitefly nymphs (Bemisia tabaci) when compared with spray-dried blastospores. These studies identified key storage conditions (low aw and oxygen availability) that improved blastospore storage stability at 28 °C and will facilitate the commercial development of blastospores-based bioinsecticides.
NASA Technical Reports Server (NTRS)
Gaucher, Brian P. (Inventor); Grzyb, Janusz (Inventor); Liu, Duixian (Inventor); Pfeiffer, Ullrich R. (Inventor)
2008-01-01
Apparatus and methods are provided for packaging IC chips together with integrated antenna modules designed to provide a closed EM (electromagnetic) environment for antenna radiators, thereby allowing antennas to be designed independent from the packaging technology.
MODEL 9977 B(M)F-96 SAFETY ANALYSIS REPORT FOR PACKAGING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abramczyk, G; Paul Blanton, P; Kurt Eberl, K
2006-05-18
This Safety Analysis Report for Packaging (SARP) documents the analysis and testing performed on and for the 9977 Shipping Package, referred to as the General Purpose Fissile Package (GPFP). The performance evaluation presented in this SARP documents the compliance of the 9977 package with the regulatory safety requirements for Type B packages. Per 10 CFR 71.59, for the 9977 packages evaluated in this SARP, the value of ''N'' is 50, and the Transport Index based on nuclear criticality control is 1.0. The 9977 package is designed with a high degree of single containment. The 9977 complies with 10 CFR 71more » (2002), Department of Energy (DOE) Order 460.1B, DOE Order 460.2, and 10 CFR 20 (2003) for As Low As Reasonably Achievable (ALARA) principles. The 9977 also satisfies the requirements of the Regulations for the Safe Transport of Radioactive Material--1996 Edition (Revised)--Requirements. IAEA Safety Standards, Safety Series No. TS-R-1 (ST-1, Rev.), International Atomic Energy Agency, Vienna, Austria (2000). The 9977 package is designed, analyzed and fabricated in accordance with Section III of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel (B&PV) Code, 1992 edition.« less
An Integrated Communication Skills Package for Undergraduate Chemists
NASA Astrophysics Data System (ADS)
Kerr, W. J.; Murray, R. E. G.; Moore, B. D.; Nonhebel, D. C.
2000-02-01
Positive feedback and evaluations were provided by students, graduates, academic staff in the department, and industrial contacts and employers. The funding council (Scottish Higher Education Funding Council), in the report on the Teaching Quality Assessment visit, identified this communication skills package as one of the Department's strengths in teaching. These positive evaluations suggest that the package is an effective means of developing the communication skills of students in chemistry.
Scheff, Deanna S; Sehgal, Blossom; Subramanyam, Bhadriraju
2018-04-18
The larvae of the Indian meal moth, Plodia interpunctella (Hübner), can invade or penetrate packaging materials and infest food products. Energy bars with three polypropylene packaging types were challenged with eggs (first instars), third instars, and fifth instars of P. interpunctella to determine package resistance at 28 °C and 65% r.h. The packing types were also challenged with two male and two female pupae of P. interpunctella under similar conditions in order to determine which package provided the greatest protection against larval penetration. Samples infested with eggs, third instars, and pupae were evaluated after 21 days and 42 days to count the number of larvae, pupae, and adults found inside the packages. Packages challenged with fifth instars were observed after 21 days to count the number of larvae, pupae, and adults inside each package. The number and diameter of the holes were determined in each package, followed by the amount of damage sustained to the energy bar. Third and fifth instars showed a higher tendency to penetrate all of the packaging types. First instars showed a reduction in package penetration ability compared with third and fifth instars. The increase in exposure time resulted in an increase in the damage sustained to the energy bars. Among packaging types, the thickest package (Test A) was most resilient to penetration by all of the larval stages. In conclusion, energy bar manufacturers need to invest more effort into improving packaging designs, creating thicker gauge films, or advancing odor barrier technology, in order to prevent penetration and infestation by P. interpunctella larvae.
Safety analysis report for packaging (onsite) steel drum
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCormick, W.A.
This Safety Analysis Report for Packaging (SARP) provides the analyses and evaluations necessary to demonstrate that the steel drum packaging system meets the transportation safety requirements of HNF-PRO-154, Responsibilities and Procedures for all Hazardous Material Shipments, for an onsite packaging containing Type B quantities of solid and liquid radioactive materials. The basic component of the steel drum packaging system is the 208 L (55-gal) steel drum.
Grebitus, Carola; Jensen, Helen H; Roosen, Jutta; Sebranek, Joseph G
2013-01-01
Consumers' perceptions and evaluations of meat quality attributes such as color and shelf life influence purchasing decisions, and these product attributes can be affected by the type of fresh meat packaging system. Modified atmosphere packaging (MAP) extends the shelf life of fresh meat and, with the inclusion of carbon monoxide (CO-MAP), achieves significant color stabilization. The objective of this study was to assess whether consumers would accept specific packaging technologies and what value consumers place on ground beef packaged under various atmospheres when their choices involved the attributes of color and shelf life. The study used nonhypothetical consumer choice experiments to determine the premiums that consumers are willing to pay for extended shelf life resulting from MAP and for the "cherry red" color in meat resulting from CO-MAP. The experimental design allowed determination of whether consumers would discount foods with MAP or CO-MAP when (i) they are given more detailed information about the technologies and (ii) they have different levels of individual knowledge and media exposure. The empirical analysis was conducted using multinomial logit models. Results indicate that consumers prefer an extension of shelf life as long as the applied technology is known and understood. Consumers had clear preferences for brighter (aerobic and CO) red color and were willing to pay $0.16/lb ($0.35/kg) for each level of change to the preferred color. More information on MAP for extending the shelf life and on CO-MAP for stabilizing color decreased consumers' willingness to pay. An increase in personal knowledge and media exposure influenced acceptance of CO-MAP negatively. The results provide quantitative measures of how packaging affects consumers' acceptance and willingness to pay for products. Such information can benefit food producers and retailers who make decisions about investing in new packaging methods.
Spielberger, Richard; Ohme, Bruce Walker; Jensen, Ronald J.
2011-06-21
A heater for heating packaged die for burn-in and heat testing is described. The heater may be a ceramic-type heater with a metal filament. The heater may be incorporated into the integrated circuit package as an additional ceramic layer of the package, or may be an external heater placed in contact with the package to heat the die. Many different types of integrated circuit packages may be accommodated. The method provides increased energy efficiency for heating the die while reducing temperature stresses on testing equipment. The method allows the use of multiple heaters to heat die to different temperatures. Faulty die may be heated to weaken die attach material to facilitate removal of the die. The heater filament or a separate temperature thermistor located in the package may be used to accurately measure die temperature.
Performance Evaluation of Real-Time Precise Point Positioning Method
NASA Astrophysics Data System (ADS)
Alcay, Salih; Turgut, Muzeyyen
2017-12-01
Post-Processed Precise Point Positioning (PPP) is a well-known zero-difference positioning method which provides accurate and precise results. After the experimental tests, IGS Real Time Service (RTS) officially provided real time orbit and clock products for the GNSS community that allows real-time (RT) PPP applications. Different software packages can be used for RT-PPP. In this study, in order to evaluate the performance of RT-PPP, 3 IGS stations are used. Results, obtained by using BKG Ntrip Client (BNC) Software v2.12, are examined in terms of both accuracy and precision.
Evaluation of Virtual Laboratory Package on Nigerian Secondary School Physics Concepts
ERIC Educational Resources Information Center
Falode, Oluwole Caleb; Gambari, Amosa Isiaka
2017-01-01
The study evaluated accessibility, flexibility, cost and learning effectiveness of researchers-developed virtual laboratory package for Nigerian secondary school physics. Based on these issues, four research questions were raised and answered. The study was a quantitative-based evaluation research. Sample for the study included 24 physics…
A Characteristics Approach to the Evaluation of Economics Software Packages.
ERIC Educational Resources Information Center
Lumsden, Keith; Scott, Alex
1988-01-01
Utilizes Bloom's Taxonomy to identify elements of teacher and student interest. Depicts the way in which these interests are developed into characteristics for use in analytically evaluating software. Illustrates the use of this evaluating technique by appraising the much used software package "Running the British Economy." (KO)
AZTEC: A parallel iterative package for the solving linear systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hutchinson, S.A.; Shadid, J.N.; Tuminaro, R.S.
1996-12-31
We describe a parallel linear system package, AZTEC. The package incorporates a number of parallel iterative methods (e.g. GMRES, biCGSTAB, CGS, TFQMR) and preconditioners (e.g. Jacobi, Gauss-Seidel, polynomial, domain decomposition with LU or ILU within subdomains). Additionally, AZTEC allows for the reuse of previous preconditioning factorizations within Newton schemes for nonlinear methods. Currently, a number of different users are using this package to solve a variety of PDE applications.
A multifaceted comparison of ArcGIS and MapMarker for automated geocoding.
Kumar, Sanjaya; Liu, Ming; Hwang, Syni-An
2012-11-01
Geocoding is increasingly being used for public health surveillance and spatial epidemiology studies. Public health departments in the United States of America (USA) often use this approach to investigate disease outbreaks and clusters or assign health records to appropriate geographic units. We evaluated two commonly used geocoding software packages, ArcGIS and MapMarker, for automated geocoding of a large number of residential addresses from health administrative data in New York State, USA to better understand their features, performance and limitations. The comparison was based on three metrics of evaluation: completeness (or match rate), geocode similarity and positional accuracy. Of the 551,798 input addresses, 318,302 (57.7%) were geocoded by MapMarker and 420,813 (76.3%) by the ArcGIS composite address locator. High similarity between the geocodes assigned by the two methods was found, especially in suburban and urban areas. Among addresses with a distance of greater than 100 m between the geocodes assigned by the two packages, the point assigned by ArcGIS was closer to the associated parcel centroid ("true" location) compared with that assigned by MapMarker. In addition, the composite address locator in ArcGIS allows users to fully utilise available reference data, which consequently results in better geocoding results. However, the positional differences found were minimal, and a large majority of addresses were placed on the same locations by both geocoding packages. Using both methods and combining the results can maximise match rates and save the time needed for manual geocoding.
Independent evaluation of the transit retrofit package safety applications : final report.
DOT National Transportation Integrated Search
2015-02-01
This report presents the methodology and results of the independent evaluation of retrofit safety packages installed on transit vehicles in the : Safety Pilot Model Deploymentpart of the United States Department of Transportations Intelligent T...
Kampfer, Kristina; Leischnig, Alexander; Spence, Charles
2017-01-01
Product packaging serves a number of distinct functions and influences the way in which consumers respond to various product offerings. The research reported here examines whether the haptic characteristics of a non-diagnostic product packaging cue, namely its weight, affects the response of consumers. This article reviews existing research on haptic transference and proposes a conceptual framework to explore how the weight of product packaging affects the flavor of the food or beverages, and, in turn, consumers’ desire for consumption and willingness to pay. Two studies demonstrate that an increase in packaging weight affects both desire and willingness to pay for the product. These effects are serially mediated by perceived flavor intensity and overall flavor evaluation. Based on these insights, implications for the design of food and beverages packaging are discussed. PMID:29020078
Kampfer, Kristina; Leischnig, Alexander; Ivens, Björn Sven; Spence, Charles
2017-01-01
Product packaging serves a number of distinct functions and influences the way in which consumers respond to various product offerings. The research reported here examines whether the haptic characteristics of a non-diagnostic product packaging cue, namely its weight, affects the response of consumers. This article reviews existing research on haptic transference and proposes a conceptual framework to explore how the weight of product packaging affects the flavor of the food or beverages, and, in turn, consumers' desire for consumption and willingness to pay. Two studies demonstrate that an increase in packaging weight affects both desire and willingness to pay for the product. These effects are serially mediated by perceived flavor intensity and overall flavor evaluation. Based on these insights, implications for the design of food and beverages packaging are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-11-03
Holston Army Ammunition Plant (HSAAP) in Holston, Tennessee, manufactures explosives from raw materials. The facility comprises two separate areas designated Area `A11 and Area 11B`. Each area is served by a steam plant which produces steam for production processes, equipment operation, space heating, domestic water heating, steam tracing, and product storage heating requirements. The purpose of this study is to identify and evaluate the technical and economic feasibility of alternative methods of meeting the steam requirements of the Area 11A11 industrial complex. The following items were specifically requested to be evaluated. Evaluate the use of two new gas-fired packaged boilersmore » sized to meet the requirements of the industrial complex. The new boilers would be installed adjacent to the existing steam plant and would utilize the existing smokestacks and steam distribution system. Evaluate using the existing steam distribution system rather than locating multiple boilers at various sites. Existing steam driven chillers will be replaced with electric driven equipment. Evaluate this impact on the steam system requirements. Field survey and test two existing gas-fired packaged boilers located at the Volunteer Army Ammunition Plant in Chattanooga, Tennessee. The two boilers were last used about 1980 and are presently laid away. The boilers are approximately the same capacity and operating characteristics as the ones at HSAAP. Relocation of the existing boilers and ancillary equipment (feedwater pumps, generators, fans, etc.) would be required as well as repairs or modifications necessary to meet current operating conditions and standards.« less
XCAT/DRASIM: a realistic CT/human-model simulation package
NASA Astrophysics Data System (ADS)
Fung, George S. K.; Stierstorfer, Karl; Segars, W. Paul; Taguchi, Katsuyuki; Flohr, Thomas G.; Tsui, Benjamin M. W.
2011-03-01
The aim of this research is to develop a complete CT/human-model simulation package by integrating the 4D eXtended CArdiac-Torso (XCAT) phantom, a computer generated NURBS surface based phantom that provides a realistic model of human anatomy and respiratory and cardiac motions, and the DRASIM (Siemens Healthcare) CT-data simulation program. Unlike other CT simulation tools which are based on simple mathematical primitives or voxelized phantoms, this new simulation package has the advantages of utilizing a realistic model of human anatomy and physiological motions without voxelization and with accurate modeling of the characteristics of clinical Siemens CT systems. First, we incorporated the 4D XCAT anatomy and motion models into DRASIM by implementing a new library which consists of functions to read-in the NURBS surfaces of anatomical objects and their overlapping order and material properties in the XCAT phantom. Second, we incorporated an efficient ray-tracing algorithm for line integral calculation in DRASIM by computing the intersection points of the rays cast from the x-ray source to the detector elements through the NURBS surfaces of the multiple XCAT anatomical objects along the ray paths. Third, we evaluated the integrated simulation package by performing a number of sample simulations of multiple x-ray projections from different views followed by image reconstruction. The initial simulation results were found to be promising by qualitative evaluation. In conclusion, we have developed a unique CT/human-model simulation package which has great potential as a tool in the design and optimization of CT scanners, and the development of scanning protocols and image reconstruction methods for improving CT image quality and reducing radiation dose.
Rastgou, Fereydoon; Shojaeifard, Maryam; Amin, Ahmad; Ghaedian, Tahereh; Firoozabadi, Hasan; Malek, Hadi; Yaghoobi, Nahid; Bitarafan-Rajabi, Ahmad; Haghjoo, Majid; Amouzadeh, Hedieh; Barati, Hossein
2014-12-01
Recently, the phase analysis of gated single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) has become feasible via several software packages for the evaluation of left ventricular mechanical dyssynchrony. We compared two quantitative software packages, quantitative gated SPECT (QGS) and Emory cardiac toolbox (ECTb), with tissue Doppler imaging (TDI) as the conventional method for the evaluation of left ventricular mechanical dyssynchrony. Thirty-one patients with severe heart failure (ejection fraction ≤35%) and regular heart rhythm, who referred for gated-SPECT MPI, were enrolled. TDI was performed within 3 days after MPI. Dyssynchrony parameters derived from gated-SPECT MPI were analyzed by QGS and ECTb and were compared with the Yu index and septal-lateral wall delay measured by TDI. QGS and ECTb showed a good correlation for assessment of phase histogram bandwidth (PHB) and phase standard deviation (PSD) (r = 0.664 and r = 0.731, P < .001, respectively). However, the mean value of PHB and PSD by ECTb was significantly higher than that of QGS. No significant correlation was found between ECTb and QGS and the Yu index. Nevertheless, PHB, PSD, and entropy derived from QGS revealed a significant (r = 0.424, r = 0.478, r = 0.543, respectively; P < .02) correlation with septal-lateral wall delay. Despite a good correlation between QGS and ECTb software packages, different normal cut-off values of PSD and PHB should be defined for each software package. There was only a modest correlation between phase analysis of gated-SPECT MPI and TDI data, especially in the population of heart failure patients with both narrow and wide QRS complex.
Hirsch, Robert M.; De Cicco, Laura A.
2015-01-01
Evaluating long-term changes in river conditions (water quality and discharge) is an important use of hydrologic data. To carry out such evaluations, the hydrologist needs tools to facilitate several key steps in the process: acquiring the data records from a variety of sources, structuring it in ways that facilitate the analysis, processing the data with routines that extract information about changes that may be happening, and displaying findings with graphical techniques. A pair of tightly linked R packages, called dataRetrieval and EGRET (Exploration and Graphics for RivEr Trends), have been developed for carrying out each of these steps in an integrated manner. They are designed to easily accept data from three sources: U.S. Geological Survey hydrologic data, U.S. Environmental Protection Agency (EPA) STORET data, and user-supplied flat files. The dataRetrieval package not only serves as a “front end” to the EGRET package, it can also be used to easily download many types of hydrologic data and organize it in ways that facilitate many other hydrologic applications. The EGRET package has components oriented towards the description of long-term changes in streamflow statistics (high flow, average flow, and low flow) as well as changes in water quality. For the water-quality analysis, it uses Weighted Regressions on Time, Discharge and Season (WRTDS) to describe long-term trends in both concentration and flux. EGRET also creates a wide range of graphical presentations of the water-quality data and of the WRTDS results. This report serves as a user guide to these two R packages, providing detailed guidance on installation and use of the software, documentation of the analysis methods used, as well as guidance on some of the kinds of questions and approaches that the software can facilitate.
Relative entropy and optimization-driven coarse-graining methods in VOTCA
Mashayak, S. Y.; Jochum, Mara N.; Koschke, Konstantin; ...
2015-07-20
We discuss recent advances of the VOTCA package for systematic coarse-graining. Two methods have been implemented, namely the downhill simplex optimization and the relative entropy minimization. We illustrate the new methods by coarse-graining SPC/E bulk water and more complex water-methanol mixture systems. The CG potentials obtained from both methods are then evaluated by comparing the pair distributions from the coarse-grained to the reference atomistic simulations.We have also added a parallel analysis framework to improve the computational efficiency of the coarse-graining process.
2006-06-30
KENNEDY SPACE CENTER, FLA. - In the Space Station Processing Facility at NASA's Kennedy Space Center, John Hoog packs up food containers with the meals prepared for the crew of mission STS-121. Hoog is a USA-FCE/EVA representative from Johnson Space Center. Astronauts select their own menus from a large array of food items. Astronauts are supplied with three balanced meals, plus snacks. Foods flown on space missions are researched and developed at the Space Food Systems Laboratory at the Johnson Space Center (JSC) in Houston, which is staffed by food scientists, dietitians and engineers. Foods are analyzed through nutritional analysis, sensory evaluation, storage studies, packaging evaluations and many other methods. Each astronaut’s food is stored aboard the space shuttle and is identified by a colored dot affixed to each package. Launch of Space Shuttle Discovery on mission STS-121 is scheduled for July 1. Photo credit: NASA/Jack Pfaller
2006-06-30
KENNEDY SPACE CENTER, FLA. - In the Space Station Processing Facility at NASA's Kennedy Space Center, John Hoog reaches for a container filled with prepared meals for the crew of mission STS-121 to secure it for flight. Hoog is a USA-FCE/EVA representative from Johnson Space Center. Astronauts select their own menus from a large array of food items. Astronauts are supplied with three balanced meals, plus snacks. Foods flown on space missions are researched and developed at the Space Food Systems Laboratory at the Johnson Space Center (JSC) in Houston, which is staffed by food scientists, dietitians and engineers. Foods are analyzed through nutritional analysis, sensory evaluation, storage studies, packaging evaluations and many other methods. Each astronaut’s food is stored aboard the space shuttle and is identified by a colored dot affixed to each package. Launch of Space Shuttle Discovery on mission STS-121 is scheduled for July 1. Photo credit: NASA/Jack Pfaller
2006-06-30
KENNEDY SPACE CENTER, FLA. - In the Space Station Processing Facility at NASA's Kennedy Space Center, John Hoog gets ready to pack the food containers with the meals prepared for the crew of mission STS-121. Hoog is a USA-FCE/EVA representative from Johnson Space Center.Astronauts select their own menus from a large array of food items. Astronauts are supplied with three balanced meals, plus snacks. Foods flown on space missions are researched and developed at the Space Food Systems Laboratory at the Johnson Space Center (JSC) in Houston, which is staffed by food scientists, dietitians and engineers. Foods are analyzed through nutritional analysis, sensory evaluation, storage studies, packaging evaluations and many other methods. Each astronaut’s food is stored aboard the space shuttle and is identified by a colored dot affixed to each package. Launch of Space Shuttle Discovery on mission STS-121 is scheduled for July 1. Photo credit: NASA/Jack Pfaller
NASA Technical Reports Server (NTRS)
Capo, M. A.; Disney, R. K.
1971-01-01
The work performed in the following areas is summarized: (1) Analysis of Realistic nuclear-propelled vehicle was analyzed using the Marshall Space Flight Center computer code package. This code package includes one and two dimensional discrete ordinate transport, point kernel, and single scatter techniques, as well as cross section preparation and data processing codes, (2) Techniques were developed to improve the automated data transfer in the coupled computation method of the computer code package and improve the utilization of this code package on the Univac-1108 computer system. (3) The MSFC master data libraries were updated.
Consumer preferences for beef color and packaging did not affect eating satisfaction.
Carpenter, C E; Cornforth, D P; Whittier, D
2001-04-01
We investigated whether consumer preferences for beef colors (red, purple, and brown) or for beef packaging systems (modified atmosphere, MAP; vacuum skin pack, VSP; or overwrap with polyvinyl chloride, PVC) influenced taste scores of beef steaks and patties. To test beef color effects, boneless beef top loin steaks (choice) and ground beef patties (20% fat) were packaged in different atmospheres to promote development of red, purple, and brown color. To test effects of package type, steaks and patties were pre-treated with carbon monoxide in MAP to promote development of red color, and some meat was repackaged using VSP or PVC overwrap. The differently colored and packaged meats were separately displayed for members of four consumer panels who evaluated appearance and indicated their likelihood to purchase similar meat. Next, the panelists tasted meat samples from what they had been told were the packaging treatments just observed. However, the meat samples actually served were from a single untreated steak or patty. Thus, any difference in taste scores should reflect expectations established during the visual evaluation. The same ballot and sample coding were used for both the visual and taste evaluations. Color and packaging influenced (P<0.001) appearance scores and likelihood to purchase. Appearance scores were rated red>purple >brown and PVC >VSP>MAP. Appearance scores and likelihood to purchase were correlated (r=0.9). However, color or packaging did not affect (P>0.5) taste scores. Thus, consumer preferences for beef color and packaging influenced likelihood to purchase, but did not bias eating satisfaction.
Safety evaluation for packaging (onsite) concrete-lined waste packaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Romano, T.
1997-09-25
The Pacific Northwest National Laboratory developed a package to ship Type A, non-transuranic, fissile excepted quantities of liquid or solid radioactive material and radioactive mixed waste to the Central Waste Complex for storage on the Hanford Site.
Pre-release plastic packaging of MEMS and IMEMS devices
Peterson, Kenneth A.; Conley, William R.
2002-01-01
A method is disclosed for pre-release plastic packaging of MEMS and IMEMS devices. The method can include encapsulating the MEMS device in a transfer molded plastic package. Next, a perforation can be made in the package to provide access to the MEMS elements. The non-ablative material removal process can include wet etching, dry etching, mechanical machining, water jet cutting, and ultrasonic machining, or any combination thereof. Finally, the MEMS elements can be released by using either a wet etching or dry plasma etching process. The MEMS elements can be protected with a parylene protective coating. After releasing the MEMS elements, an anti-stiction coating can be applied. The perforating step can be applied to both sides of the device or package. A cover lid can be attached to the face of the package after releasing any MEMS elements. The cover lid can include a window for providing optical access. The method can be applied to any plastic packaged microelectronic device that requires access to the environment, including chemical, pressure, or temperature-sensitive microsensors; CCD chips, photocells, laser diodes, VCSEL's, and UV-EPROMS. The present method places the high-risk packaging steps ahead of the release of the fragile portions of the device. It also provides protection for the die in shipment between the molding house and the house that will release the MEMS elements and subsequently treat the surfaces.
Yang, Xiaoyin; Wu, Shuang; Hopkins, David L; Liang, Rongrong; Zhu, Lixian; Zhang, Yimin; Luo, Xin
2018-08-01
This study investigated the proteome basis for color stability variations in beef steaks packaged under two modified atmosphere packaging (MAP) methods: HiOx-MAP (80% O 2 /20% CO 2 ) and CO-MAP (0.4% CO/30% CO 2 /69.6% N 2 ) during 15 days of storage. The color stability, pH, and sarcoplasmic proteome analysis of steaks were evaluated on days 0, 5, 10 and 15 of storage. Proteomic results revealed that the differential expression of the sarcoplasmic proteome during storage contributed to the variations in meat color stability between the two MAP methods. Compared with HiOx-MAP steaks, some glycolytic and energy metabolic enzymes important in NADH regeneration and antioxidant processes, antioxidant peroxiredoxins (thioredoxin-dependent peroxide reductase, peroxiredoxin-2, peroxiredoxin-6) and protein DJ-1 were more abundant in CO-MAP steaks. The over-expression of these proteins could induce CO-MAP steaks to maintain high levels of metmyoglobin reducing activity and oxygen consumption rate, resulting in CO-MAP steaks exhibiting better color stability than HiOx-MAP steaks during storage. Copyright © 2018 Elsevier Ltd. All rights reserved.
Re-design of apple pia packaging using quality function deployment method
NASA Astrophysics Data System (ADS)
Pulungan, M. H.; Nadira, N.; Dewi, I. A.
2018-03-01
This study was aimed to identify the attributes for premium apple pia packaging, to determine the technical response to be carried out by Permata Agro Mandiri Small and Medium Enterprise (SME) and to design a new apple pie packaging acceptable by the SME. The Quality Function Deployment (QFD) method was employed to improve the apple pia packaging design, which consisted of seven stages in data analysis. The results indicated that whats attribute required by the costumers include graphic design, dimensions, capacity, shape, strength, and resistance of packaging. While, the technical responses to be conducted by the SMEs were as follows: attractive visual packaging designs, attractive colors, clear images and information, packaging size dimensions, a larger capacity packaging (more product content), ergonomic premium packaging, not easily torn, and impact resistant packaging materials. The findings further confirmed that the design of premium apple pia packaging accepted by the SMES was the one with the capacity of ten apple pia or 200 g weight, and with rectangular or beam shape form. The packaging material used was a duplex carton with 400 grammage (g/m2), the outer part of the packaging was coated with plastic and the inside was added with duplex carton. The acceptable packaging dimension was 30 cm x 5 cm x 3 cm (L x W x H) with a mix of black and yellow color in the graphical design.
spMC: an R-package for 3D lithological reconstructions based on spatial Markov chains
NASA Astrophysics Data System (ADS)
Sartore, Luca; Fabbri, Paolo; Gaetan, Carlo
2016-09-01
The paper presents the spatial Markov Chains (spMC) R-package and a case study of subsoil simulation/prediction located in a plain site of Northeastern Italy. spMC is a quite complete collection of advanced methods for data inspection, besides spMC implements Markov Chain models to estimate experimental transition probabilities of categorical lithological data. Furthermore, simulation methods based on most known prediction methods (as indicator Kriging and CoKriging) were implemented in spMC package. Moreover, other more advanced methods are available for simulations, e.g. path methods and Bayesian procedures, that exploit the maximum entropy. Since the spMC package was developed for intensive geostatistical computations, part of the code is implemented for parallel computations via the OpenMP constructs. A final analysis of this computational efficiency compares the simulation/prediction algorithms by using different numbers of CPU cores, and considering the example data set of the case study included in the package.
A study of the stress wave factor technique for nondestructive evaluation of composite materials
NASA Technical Reports Server (NTRS)
Sarrafzadeh-Khoee, A.; Kiernan, M. T.; Duke, J. C., Jr.; Henneke, E. G., II
1986-01-01
The acousto-ultrasonic method of nondestructive evaluation is an extremely sensitive means of assessing material response. Efforts continue to complete the understanding of this method. In order to achieve the full sensitivity of the technique, extreme care must be taken in its performance. This report provides an update of the efforts to advance the understanding of this method and to increase its application to the nondestructive evaluation of composite materials. Included are descriptions of a novel optical system that is capable of measuring in-plane and out-of-plane displacements, an IBM PC-based data acquisition system, an extensive data analysis software package, the azimuthal variation of acousto-ultrasonic behavior in graphite/epoxy laminates, and preliminary examination of processing variation in graphite-aluminum tubes.
Construction and comparative evaluation of different activity detection methods in brain FDG-PET.
Buchholz, Hans-Georg; Wenzel, Fabian; Gartenschläger, Martin; Thiele, Frank; Young, Stewart; Reuss, Stefan; Schreckenberger, Mathias
2015-08-18
We constructed and evaluated reference brain FDG-PET databases for usage by three software programs (Computer-aided diagnosis for dementia (CAD4D), Statistical Parametric Mapping (SPM) and NEUROSTAT), which allow a user-independent detection of dementia-related hypometabolism in patients' brain FDG-PET. Thirty-seven healthy volunteers were scanned in order to construct brain FDG reference databases, which reflect the normal, age-dependent glucose consumption in human brain, using either software. Databases were compared to each other to assess the impact of different stereotactic normalization algorithms used by either software package. In addition, performance of the new reference databases in the detection of altered glucose consumption in the brains of patients was evaluated by calculating statistical maps of regional hypometabolism in FDG-PET of 20 patients with confirmed Alzheimer's dementia (AD) and of 10 non-AD patients. Extent (hypometabolic volume referred to as cluster size) and magnitude (peak z-score) of detected hypometabolism was statistically analyzed. Differences between the reference databases built by CAD4D, SPM or NEUROSTAT were observed. Due to the different normalization methods, altered spatial FDG patterns were found. When analyzing patient data with the reference databases created using CAD4D, SPM or NEUROSTAT, similar characteristic clusters of hypometabolism in the same brain regions were found in the AD group with either software. However, larger z-scores were observed with CAD4D and NEUROSTAT than those reported by SPM. Better concordance with CAD4D and NEUROSTAT was achieved using the spatially normalized images of SPM and an independent z-score calculation. The three software packages identified the peak z-scores in the same brain region in 11 of 20 AD cases, and there was concordance between CAD4D and SPM in 16 AD subjects. The clinical evaluation of brain FDG-PET of 20 AD patients with either CAD4D-, SPM- or NEUROSTAT-generated databases from an identical reference dataset showed similar patterns of hypometabolism in the brain regions known to be involved in AD. The extent of hypometabolism and peak z-score appeared to be influenced by the calculation method used in each software package rather than by different spatial normalization parameters.
Pérez-Esteve, Edgar; Bernardos, Andrea; Martínez-Máñez, Ramón; Barat, José M
2013-04-01
In recent years nanotechnology has become a significant component in food industry. It is present in all food chain steps, from the design of new ingredients or additives, to the most modern systems of food quality methods or packaging, demonstrating the great potential of this new technology in a sector as traditional as food. However, while interest by industry in nanotechnology increases, the rejection by consumers, concerned about the potential risk, does too. The aim of this review is to evaluate the development of food nanotechnology by means of a patent analysis, highlighting current applications of nanotechnology along the whole food chain and contextualizing this evolution in the social scene.
ERIC Educational Resources Information Center
Weaver, Dave, Ed.
This document consists of 30 microcomputer software package evaluations prepared for the MicroSIFT (Microcomputer Software and Information for Teachers) Clearinghouse at the Northwest Regional Educational Laboratory (NWREL). The concise, single-sheet resume describing and evaluating each software package includes source, cost, ability level,…
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Uniform test method for the measurement of energy efficiency of commercial packaged boilers. 431.86 Section 431.86 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Packaged...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Uniform test method for the measurement of energy efficiency of commercial packaged boilers. 431.86 Section 431.86 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Packaged...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Uniform test method for the measurement of energy efficiency of commercial packaged boilers. 431.86 Section 431.86 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Packaged...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Uniform test method for the measurement of energy efficiency of commercial packaged boilers. 431.86 Section 431.86 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Packaged...
Standardised (plain) packaging: the time for implementation has come.
Hoek, Janet; Edwards, Richard; Daube A O, Mike
2015-07-03
Although a growing number of countries have passed legislation to introduce standardised (or 'plain') packaging, New Zealand's legislation is currently stalled. The research evidence supporting standardised packaging is strong. Furthermore, evaluations from Australia, the first country to introduce this measure, show standardised packaging is reducing the appeal of smoking. Tobacco consumption in Australia has also fallen since the introduction of standardised packaging. The government should reassert its commitment to New Zealand's Smokefree 2025 goal by recognising the Australian evidence and passing and implementing standardised packaging as soon as possible.
Evaluation of the prototype dual-axis wall attitude measurement sensor
NASA Technical Reports Server (NTRS)
Wong, Douglas T.
1994-01-01
A prototype dual-axis electrolytic tilt sensor package for angular position measurements was built and evaluated in a laboratory environment. The objective was to investigate the use of this package for making wind tunnel wall attitude measurements for the National Transonic Facility (NTF) at NASA Langley Research Center (LaRC). The instrumentation may replace an existing, more costly, and less rugged servo accelerometer package (angle-of-attack package) currently in use. The dual-axis electrolytic tilt sensor package contains two commercial electrolytic tilt sensors thermally insulated with NTF foam, all housed within a stainless steel package. The package is actively heated and maintained at 160 F using foil heating elements. The laboratory evaluation consisted of a series of tests to characterize the linearity, repeatability, cross-axis interaction, lead wire effect, step response, thermal time constant, and rectification errors. Tests revealed that the total RMS errors for the x-axis sensor is 0.084 degree, and 0.182 degree for the y-axis sensor. The RMS errors are greater than the 0.01 degree specification required for NTF wall attitude measurements. It is therefore not a viable replacement for the angle-of-attack package in the NTF application. However, with some physical modifications, it can be used as an inexpensive 5-degree range dual-axis inclinometer with overall accuracy approaching 0.01 degree under less harsh environments. Also, the data obtained from the tests can be valuable for wind tunnel applications of most types of electrolytic tilt sensors.
GDF v2.0, an enhanced version of GDF
NASA Astrophysics Data System (ADS)
Tsoulos, Ioannis G.; Gavrilis, Dimitris; Dermatas, Evangelos
2007-12-01
An improved version of the function estimation program GDF is presented. The main enhancements of the new version include: multi-output function estimation, capability of defining custom functions in the grammar and selection of the error function. The new version has been evaluated on a series of classification and regression datasets, that are widely used for the evaluation of such methods. It is compared to two known neural networks and outperforms them in 5 (out of 10) datasets. Program summaryTitle of program: GDF v2.0 Catalogue identifier: ADXC_v2_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADXC_v2_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 98 147 No. of bytes in distributed program, including test data, etc.: 2 040 684 Distribution format: tar.gz Programming language: GNU C++ Computer: The program is designed to be portable in all systems running the GNU C++ compiler Operating system: Linux, Solaris, FreeBSD RAM: 200000 bytes Classification: 4.9 Does the new version supersede the previous version?: Yes Nature of problem: The technique of function estimation tries to discover from a series of input data a functional form that best describes them. This can be performed with the use of parametric models, whose parameters can adapt according to the input data. Solution method: Functional forms are being created by genetic programming which are approximations for the symbolic regression problem. Reasons for new version: The GDF package was extended in order to be more flexible and user customizable than the old package. The user can extend the package by defining his own error functions and he can extend the grammar of the package by adding new functions to the function repertoire. Also, the new version can perform function estimation of multi-output functions and it can be used for classification problems. Summary of revisions: The following features have been added to the package GDF: Multi-output function approximation. The package can now approximate any function f:R→R. This feature gives also to the package the capability of performing classification and not only regression. User defined function can be added to the repertoire of the grammar, extending the regression capabilities of the package. This feature is limited to 3 functions, but easily this number can be increased. Capability of selecting the error function. The package offers now to the user apart from the mean square error other error functions such as: mean absolute square error, maximum square error. Also, user defined error functions can be added to the set of error functions. More verbose output. The main program displays more information to the user as well as the default values for the parameters. Also, the package gives to the user the capability to define an output file, where the output of the gdf program for the testing set will be stored after the termination of the process. Additional comments: A technical report describing the revisions, experiments and test runs is packaged with the source code. Running time: Depending on the train data.
Modular vaccine packaging increases packing efficiency
Norman, Bryan A.; Rajgopal, Jayant; Lim, Jung; Gorham, Katrin; Haidari, Leila; Brown, Shawn T.; Lee, Bruce Y.
2015-01-01
Background Within a typical vaccine supply chain, vaccines are packaged into individual cylindrical vials (each containing one or more doses) that are bundled together in rectangular “inner packs” for transport via even larger groupings such as cold boxes and vaccine carriers. The variability of vaccine inner pack and vial size may hinder efficient vaccine distribution because it constrains packing of cold boxes and vaccine carriers to quantities that are often inappropriate or suboptimal in the context of country-specific vaccination guidelines. Methods We developed in Microsoft Excel (Microsoft Corp., Redmond, WA) a spreadsheet model that evaluated the impact of different packing schemes for the Benin routine regimen plus the introduction of the Rotarix vaccine. Specifically, we used the model to compare the current packing scheme to that of a proposed modular packing scheme. Results Conventional packing of a Dometic RCW25 that aims to maximize fully-immunized children (FICs) results in 123 FICs and a packing efficiency of 81.93% compared to a maximum of 155 FICs and 94.1% efficiency for an alternative modular packaging system. Conclusions Our analysis suggests that modular packaging systems could offer significant advantages over conventional vaccine packaging systems with respect to space efficiency and potential FICs, when they are stored in standard vaccine carrying devices. This allows for more vaccines to be stored within the same volume while also simplifying the procedures used by field workers to pack storage devices. Ultimately, modular packaging systems could be a simple way to help increase vaccine coverage worldwide. PMID:25957666
Abramov, Y A; Volkov, A; Wu, G; Coppens, P
2000-11-01
A new module interfaced to the XD programming package has been used in the evaluation of intermolecular interactions and lattice energies of the crystals of p-nitroaniline, L-asparagine monohydrate and the pentapeptide Boc-Gln-D-Iva-Hyp-Ala-Phol (Boc = butoxycarbonyl, Iva = isovaline = ethylalanine, Phol = phenylalaninol). The electrostatic interactions are evaluated with the atom-centered distributed multipoles from KRMM (kappa'-restricted multipole model) refinements, using the Buckingham expression for non-overlapping charge densities. Results for p-nitroaniline are compared with Hartree-Fock (HF), density functional (DFT) and Moller-Plesset (MP2) supermolecular calculations and with HF and DFT periodic calculations. The HF and DFT methods fail to predict the stability of the p-nitroaniline crystal but the results of the experimental charge-density approach (ECDA) are in good agreement with both MP2 interaction energies and the experimental lattice energy. ECDA results for L-asparagine monohydrate compare well with those from DFT supermolecular and periodic HF calculations. The disorder of the terminal group in the pentapeptide, which persists at the experimental temperature of 20 K, corresponds to an energy difference of only 0.35 kJ mol(-1), which is too small to be reproduced with current methods.
Detecting small holes in packages
Kronberg, James W.; Cadieux, James R.
1996-01-01
A package containing a tracer gas, and a method for determining the presence of a hole in the package by sensing the presence of the gas outside the package. The preferred tracer gas, especially for food packaging, is sulfur hexafluoride. A quantity of the gas is added to the package and the package is closed. The concentration of the gas in the atmosphere outside the package is measured and compared to a predetermined value of the concentration of the gas in the absence of the package. A measured concentration greater than the predetermined value indicates the presence of a hole in the package. Measuring may be done in a chamber having a lower pressure than that in the package.
Communicating spatial uncertainty to non-experts using R
NASA Astrophysics Data System (ADS)
Luzzi, Damiano; Sawicka, Kasia; Heuvelink, Gerard; de Bruin, Sytze
2016-04-01
Effective visualisation methods are important for the efficient use of uncertainty information for various groups of users. Uncertainty propagation analysis is often used with spatial environmental models to quantify the uncertainty within the information. A challenge arises when trying to effectively communicate the uncertainty information to non-experts (not statisticians) in a wide range of cases. Due to the growing popularity and applicability of the open source programming language R, we undertook a project to develop an R package that facilitates uncertainty propagation analysis in spatial environmental modelling. The package has implemented Monte Carlo algorithms for uncertainty propagation, the output of which is represented by an ensemble of model outputs (i.e. a sample from a probability distribution). Numerous visualisation methods exist that aim to present such spatial uncertainty information both statically, dynamically and interactively. To provide the most universal visualisation tools for non-experts, we conducted a survey on a group of 20 university students and assessed the effectiveness of selected static and interactive methods for visualising uncertainty in spatial variables such as DEM and land cover. The static methods included adjacent maps and glyphs for continuous variables. Both allow for displaying maps with information about the ensemble mean, variance/standard deviation and prediction intervals. Adjacent maps were also used for categorical data, displaying maps of the most probable class, as well as its associated probability. The interactive methods included a graphical user interface, which in addition to displaying the previously mentioned variables also allowed for comparison of joint uncertainties at multiple locations. The survey indicated that users could understand the basics of the uncertainty information displayed in the static maps, with the interactive interface allowing for more in-depth information. Subsequently, the R package included a collation of the plotting functions that were evaluated in the survey. The implementation of static visualisations was done via calls to the 'ggplot2' package. This allowed the user to provide control over the content, legend, colours, axes and titles. The interactive methods were implemented using the 'shiny' package allowing users to activate the visualisation of statistical descriptions of uncertainty through interaction with a plotted map of means. This research brings uncertainty visualisation to a broader audience through the development of tools for visualising uncertainty using open source software.
Safety. Fire Service Certification Series. Unit FSCS-FF-2-80.
ERIC Educational Resources Information Center
Pribyl, Paul F.
This training unit on safety is part of a 17-unit course package written to aid instructors in the development, teaching, and evaluation of fire fighters in the Wisconsin Fire Service Certification Series. The purpose stated for the 4-hour unit is to assist firefighters in understanding the hazards of their profession and some methods of reducing…
ERIC Educational Resources Information Center
Loeffler, Gordon
The intent of this field tested instructional package is to acquaint the student with the methods and processes used in the production of goods. Defining behavioral objectives, the course description includes media guide, suggested classroom activities, and sample student evaluation forms as well as the basic information section. The course…
Yu, Hwan Hee; Song, Myung Wook; Kim, Tae-Kyung; Choi, Yun-Sang; Cho, Gyu Yong; Lee, Na-Kyoung; Paik, Hyun-Dong
2018-01-01
Abstract The objective of this study was to investigate comparison of physicochemical, microbiological, and sensory characteristics of Hanwoo eye of round by various packaging methods [wrapped packaging (WP), modified atmosphere packaging (MAP), vacuum packaging (VP) with three different vacuum films, and vacuum skin packaging (VSP)] at a small scale. Packaged Hanwoo beef samples were stored in refrigerated conditions (4±1°C) for 28 days. Packaged beef was sampled on days 0, 7, 14, 21, and 28. Physicochemical [pH, surface color, thiobarbituric acid reactive substances (TBARS), and volatile basic nitrogen (VBN) values], microbiological, and sensory analysis of packaged beef samples were performed. VP and VSP samples showed low TBARS and VBN values, and pH and surface color did not change substantially during the 28-day period. For VSP, total viable bacteria, psychrotrophic bacteria, lactic acid bacteria, and coliform counts were lower than those for other packaging systems. Salmonella spp. and Escherichia coli O157:H7 were not detected in any packaged beef samples. A sensory analysis showed that the scores for appearance, flavor, color, and overall acceptability did not change significantly until day 7. In total, VSP was effective with respect to significantly higher a* values, physicochemical stability, and microbial safety in Hanwoo packaging (p<0.05). PMID:29805283
QuantWorm: a comprehensive software package for Caenorhabditis elegans phenotypic assays.
Jung, Sang-Kyu; Aleman-Meza, Boanerges; Riepe, Celeste; Zhong, Weiwei
2014-01-01
Phenotypic assays are crucial in genetics; however, traditional methods that rely on human observation are unsuitable for quantitative, large-scale experiments. Furthermore, there is an increasing need for comprehensive analyses of multiple phenotypes to provide multidimensional information. Here we developed an automated, high-throughput computer imaging system for quantifying multiple Caenorhabditis elegans phenotypes. Our imaging system is composed of a microscope equipped with a digital camera and a motorized stage connected to a computer running the QuantWorm software package. Currently, the software package contains one data acquisition module and four image analysis programs: WormLifespan, WormLocomotion, WormLength, and WormEgg. The data acquisition module collects images and videos. The WormLifespan software counts the number of moving worms by using two time-lapse images; the WormLocomotion software computes the velocity of moving worms; the WormLength software measures worm body size; and the WormEgg software counts the number of eggs. To evaluate the performance of our software, we compared the results of our software with manual measurements. We then demonstrated the application of the QuantWorm software in a drug assay and a genetic assay. Overall, the QuantWorm software provided accurate measurements at a high speed. Software source code, executable programs, and sample images are available at www.quantworm.org. Our software package has several advantages over current imaging systems for C. elegans. It is an all-in-one package for quantifying multiple phenotypes. The QuantWorm software is written in Java and its source code is freely available, so it does not require use of commercial software or libraries. It can be run on multiple platforms and easily customized to cope with new methods and requirements.
Williams, Julia; O'Connor, Mórna; Windle, Richard; Wharrad, Heather J
2015-12-01
Clinical skills are a critical component of pre-registration nurse education in the United Kingdom, yet there is widespread concern about the clinical skills displayed by newly-qualified nurses. Novel means of supporting clinical skills education are required to address this. A package of Reusable Learning Objects (RLOs) was developed to supplement pre-registration teaching on the clinical skill of administering injection medication. RLOs are electronic resources addressing a single learning objective whose interactivity facilitates learning. This article evaluates a package of five injection RLOs across three studies: (1) questionnaires administered to pre-registration nursing students at University of Nottingham (UoN) (n=46) evaluating the RLO package as a whole; (2) individual RLOs evaluated in online questionnaires by educators and students from UoN; from other national and international institutions; and healthcare professionals (n=265); (3) qualitative evaluation of the RLO package by UoN injection skills tutors (n=6). Data from all studies were assessed for (1) access to, (2) usefulness, (3) impact and (4) integration of the RLOs. Study one found that pre-registration nursing students rate the RLO package highly across all categories, particularly underscoring the value of their self-test elements. Study two found high ratings in online assessments of individual RLOs by multiple users. The global reach is particularly encouraging here. Tutors reported insufficient levels of student-RLO access, which might be explained by the timing of their student exposure. Tutors integrate RLOs into teaching and agree on their use as teaching supplements, not substitutes for face-to-face education. This evaluation encompasses the first years postpackage release. Encouraging data on evaluative categories in this early review suggest that future evaluations are warranted to track progress as the package is adopted and evaluated more widely. Copyright © 2015 Elsevier Ltd. All rights reserved.
An experimental analysis of the effectiveness and sustainability of a Chinese tutoring package.
Wu, Hang; Miller, L Keith
2012-01-01
This experiment evaluated the effects of training tutors to use an instructional package to teach pronunciation and translation of the Chinese language. Tutors' correct use of the package increased from 68% of trials to 92% after training, and student correct pronunciation increased from 45% to 90%, with similar effects for translation. Continued use of the package, high social validity, and extended follow-up suggest that use of the package may be sustainable.
AN EXPERIMENTAL ANALYSIS OF THE EFFECTIVENESS AND SUSTAINABILITY OF A CHINESE TUTORING PACKAGE
Wu, Hang; Miller, L. Keith
2012-01-01
This experiment evaluated the effects of training tutors to use an instructional package to teach pronunciation and translation of the Chinese language. Tutors' correct use of the package increased from 68% of trials to 92% after training, and student correct pronunciation increased from 45% to 90%, with similar effects for translation. Continued use of the package, high social validity, and extended follow-up suggest that use of the package may be sustainable. PMID:22403470
2014-01-01
Background The UK has one of the highest fatality rates for deaths from fire-related injuries in children aged 0–14 years; these injuries have the steepest social gradient of all injuries in the UK. Children’s centres provide children under five years old and their families with a range of services and information, including home safety, but their effectiveness in promoting injury prevention has yet to be evaluated. We developed a fire prevention intervention for use in children’s centres comprising an Injury Prevention Briefing (IPB) which provides evidence on what works and best practice from those running injury prevention programmes, and a facilitation package to support implementation of the IPB. This protocol describes the design and methods of a trial evaluating the effectiveness and cost-effectiveness of the IPB and facilitation package in promoting fire prevention. Methods/Design Pragmatic, multicentre cluster randomised controlled trial, with a nested qualitative study, in four study centres in England. Children’s centres in the most disadvantaged areas will be eligible to participate and will be randomised to one of three treatment arms comprising: IPB with facilitation package; IPB with no facilitation package; usual care (control). The primary outcome measure will be the proportion of families who have a fire escape plan at follow-up. Eleven children’s centres per arm are required to detect an absolute difference in the percentage of families with a fire escape plan of 20% in either of the two intervention arms compared with the control arm, with 80% power and a 5% significance level (2-sided), an intraclass correlation coefficient of 0.05 and assuming outcomes are assessed on 20 families per children’s centre. Secondary outcomes include the assessment of the cost-effectiveness of the intervention, other fire safety behaviours and factors associated with degree of implementation of the IPB. Discussion This will be the first trial to develop and evaluate a fire prevention intervention for use in children’s centres in the UK. Its findings will be generalisable to children’s centres in the most disadvantaged areas of the UK and may also be generalisable to similar interventions to prevent other types of injury. Trial registration http://NCT01452191 (date of registration: 13/10/2011). PMID:24450931
ARM Data-Oriented Metrics and Diagnostics Package for Climate Model Evaluation Value-Added Product
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Chengzhu; Xie, Shaocheng
A Python-based metrics and diagnostics package is currently being developed by the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Infrastructure Team at Lawrence Livermore National Laboratory (LLNL) to facilitate the use of long-term, high-frequency measurements from the ARM Facility in evaluating the regional climate simulation of clouds, radiation, and precipitation. This metrics and diagnostics package computes climatological means of targeted climate model simulation and generates tables and plots for comparing the model simulation with ARM observational data. The Coupled Model Intercomparison Project (CMIP) model data sets are also included in the package to enable model intercomparison as demonstratedmore » in Zhang et al. (2017). The mean of the CMIP model can serve as a reference for individual models. Basic performance metrics are computed to measure the accuracy of mean state and variability of climate models. The evaluated physical quantities include cloud fraction, temperature, relative humidity, cloud liquid water path, total column water vapor, precipitation, sensible and latent heat fluxes, and radiative fluxes, with plan to extend to more fields, such as aerosol and microphysics properties. Process-oriented diagnostics focusing on individual cloud- and precipitation-related phenomena are also being developed for the evaluation and development of specific model physical parameterizations. The version 1.0 package is designed based on data collected at ARM’s Southern Great Plains (SGP) Research Facility, with the plan to extend to other ARM sites. The metrics and diagnostics package is currently built upon standard Python libraries and additional Python packages developed by DOE (such as CDMS and CDAT). The ARM metrics and diagnostic package is available publicly with the hope that it can serve as an easy entry point for climate modelers to compare their models with ARM data. In this report, we first present the input data, which constitutes the core content of the metrics and diagnostics package in section 2, and a user's guide documenting the workflow/structure of the version 1.0 codes, and including step-by-step instruction for running the package in section 3.« less
Packaging optical sensors for the real world
NASA Astrophysics Data System (ADS)
Kachmar, Wayne; Nardone, Kenneth C.
2007-09-01
Optical fiber based sensing has now moved from laboratory demonstrations to actual applications in the real world. This has necessitated an entirely new area of extrusion - the packaging (cabling) of optical fibers and sensor arrays to protect them from the intended environment and installation handling while not masking or attenuating the phenomenon that is being sensed. Although each application presents new and unique challenges, the goal is to create a packaging concept for fiber sensors. Fiber sensing applications can be narrowed down to the five items below: 1. Conventional cable packages 2. Assembled (typically by hand) discrete sensor packages 3. Package enhanced sensors (where the packaging improves the effect of the sensor) 4. Linear sensor installation packaging 5. Scalar packaging (where the cabling adds to the range of the sensor) The above applications can be accomplished in a number of ways, and methods are still being developed in this relatively new science. Some of the new technology methods being explored include: UV cured liquids; Voided space cores; Conventional cable extrusion & its determination of mechanical characteristics. This paper reviews the pluses and minuses of the above methods and how their combination ultimately determines how the fiber or sensor array is to be jacketed in order to meet the specific application requirements. This paper will also review non-standard material characteristics, strength members and their role in measuring strain and stress values along with the overall influence of packaging on optical fibers and sensor arrays.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salama, A.; Mikhail, M.
Comprehensive software packages have been developed at the Western Research Centre as tools to help coal preparation engineers analyze, evaluate, and control coal cleaning processes. The COal Preparation Software package (COPS) performs three functions: (1) data handling and manipulation, (2) data analysis, including the generation of washability data, performance evaluation and prediction, density and size modeling, evaluation of density and size partition characteristics and attrition curves, and (3) generation of graphics output. The Separation ChARacteristics Estimation software packages (SCARE) are developed to balance raw density or size separation data. The cases of density and size separation data are considered. Themore » generated balanced data can take the balanced or normalized forms. The scaled form is desirable for direct determination of the partition functions (curves). The raw and generated separation data are displayed in tabular and/or graphical forms. The computer softwares described in this paper are valuable tools for coal preparation plant engineers and operators for evaluating process performance, adjusting plant parameters, and balancing raw density or size separation data. These packages have been applied very successfully in many projects carried out by WRC for the Canadian coal preparation industry. The software packages are designed to run on a personal computer (PC).« less
Microbial barrier assessment of Tyvek stopper packaging for rubber closures.
Moldenhauer, J E; Bass, S A; Kupinski, M J; Walters, M L; Rubio, S L
1996-01-01
Two types of Tyvek and high density polyethylene or polypropylene packaging used for sterilization of rubber closures were evaluated for Microbial Barrier properties. The packaging evaluated was "Ready to Sterilize" (1) stoppers and a second test package (Test 2) which was designated as appropriate for a clean room, filled with washed and siliconized stoppers and then heat sealed. Each type of packaging was subjected to three different sterilization temperatures (125 degrees C, 128 degrees C and 131 degrees C) in a production sterilizer (15-18 psi). Following sterilization, a microbial barrier assessment was performed, using Bacillus subtilis niger (ATCC 9372), to determine whether the packaging could maintain a sterile barrier following sterilization. Results of the testing indicated that a microbial barrier was maintained for products in "Ready to Sterilize" packages at 125 degrees C and 128 degrees C. For products sterilized in the Test 2 container a microbial barrier could not be maintained at 128 degrees C, and no further testing was performed. Following sterilization at 131 degrees C physical defects were noted for the "Ready to Sterilize" bag and a microbial barrier could not be maintained.
Van Rooyen, Lauren Anne; Allen, Paul; O'Connor, David I
2017-10-01
Carbon monoxide (CO) has many value-added benefits in meat packaging due to its colour stabilising effects and enhancement of meat quality attributes. The regulation of CO within meat packaging varies worldwide and remains a topical and controversial issue. CO is prohibited in the EU for use in meat packaging mainly due to fears it may mask spoilage therefore misleading consumers. The issue of consumer acceptance of CO was not considered. This article reviews the most pertinent literature to assess if the problems associated with the prohibition have been addressed. Applying CO pretreatments prior to vacuum packaging enhances colour while allowing discolouration to occur by the use-by-date, thereby addressing concerns about safety. Recent work showing European consumer acceptance of CO in meat packaging demonstrates its future potential within the EU. The information provided may support framing future policies intended to assure consumer protection, safety, choice and interest. Re-evaluation of permitting CO as a packaging gas within the EU may be warranted. Copyright © 2017 Elsevier Ltd. All rights reserved.
HT2DINV: A 2D forward and inverse code for steady-state and transient hydraulic tomography problems
NASA Astrophysics Data System (ADS)
Soueid Ahmed, A.; Jardani, A.; Revil, A.; Dupont, J. P.
2015-12-01
Hydraulic tomography is a technique used to characterize the spatial heterogeneities of storativity and transmissivity fields. The responses of an aquifer to a source of hydraulic stimulations are used to recover the features of the estimated fields using inverse techniques. We developed a 2D free source Matlab package for performing hydraulic tomography analysis in steady state and transient regimes. The package uses the finite elements method to solve the ground water flow equation for simple or complex geometries accounting for the anisotropy of the material properties. The inverse problem is based on implementing the geostatistical quasi-linear approach of Kitanidis combined with the adjoint-state method to compute the required sensitivity matrices. For undetermined inverse problems, the adjoint-state method provides a faster and more accurate approach for the evaluation of sensitivity matrices compared with the finite differences method. Our methodology is organized in a way that permits the end-user to activate parallel computing in order to reduce the computational burden. Three case studies are investigated demonstrating the robustness and efficiency of our approach for inverting hydraulic parameters.
Faramarzi, Salar; Moradi, Mohammadreza; Abedi, Ahmad
2018-06-01
The present study aimed to develop the thinking maps training package and compare its training effect with the thinking maps method on the reading performance of second and fifth grade of elementary school male dyslexic students. For this mixed method exploratory study, from among the above mentioned grades' students in Isfahan, 90 students who met the inclusion criteria were selected by multistage sampling and randomly assigned into six experimental and control groups. The data were collected by reading and dyslexia test and Wechsler Intelligence Scale for Children-fourth edition. The results of covariance analysis indicated a significant difference between the reading performance of the experimental (thinking maps training package and thinking maps method groups) and control groups ([Formula: see text]). Moreover, there were significant differences between the thinking maps training package group and thinking maps method group in some of the subtests ([Formula: see text]). It can be concluded that thinking maps training package and the thinking maps method exert a positive influence on the reading performance of dyslexic students; therefore, thinking maps can be used as an effective training and treatment method.
Meredith, Pamela; Yeates, Harriet; Greaves, Amanda; Taylor, Michelle; Slattery, Maddy; Charters, Michelle; Hill, Melissa
2018-02-01
The application of sensory modulation approaches in mental health settings is growing in recognition internationally. However, a number of barriers have been identified as limiting the implementation of the approach, including workplace culture and a lack of accessible and effective sensory approaches training. The aim of this project was to investigate the efficacy of providing this training through a custom-designed e-learning package. Participants in the present study were predominately nurses and occupational therapists working in mental health settings in Queensland, Australia. Data were collected from 121 participants using an online survey. Significant improvements were found between pre- and post-training in participants' real and perceived levels of knowledge, their perceived levels of confidence, and their attitudes towards using sensory modulation approaches in mental health settings. The findings of the study suggest that the custom-designed sensory approaches e-learning package is an effective, accessible, acceptable, and usable method to train health professionals in sensory modulation approaches. As this study is the first to analyse the efficacy of an e-learning sensory approaches package, the results are considered preliminary, and further investigation is required. © 2017 Australian College of Mental Health Nurses Inc.
cit: hypothesis testing software for mediation analysis in genomic applications.
Millstein, Joshua; Chen, Gary K; Breton, Carrie V
2016-08-01
The challenges of successfully applying causal inference methods include: (i) satisfying underlying assumptions, (ii) limitations in data/models accommodated by the software and (iii) low power of common multiple testing approaches. The causal inference test (CIT) is based on hypothesis testing rather than estimation, allowing the testable assumptions to be evaluated in the determination of statistical significance. A user-friendly software package provides P-values and optionally permutation-based FDR estimates (q-values) for potential mediators. It can handle single and multiple binary and continuous instrumental variables, binary or continuous outcome variables and adjustment covariates. Also, the permutation-based FDR option provides a non-parametric implementation. Simulation studies demonstrate the validity of the cit package and show a substantial advantage of permutation-based FDR over other common multiple testing strategies. The cit open-source R package is freely available from the CRAN website (https://cran.r-project.org/web/packages/cit/index.html) with embedded C ++ code that utilizes the GNU Scientific Library, also freely available (http://www.gnu.org/software/gsl/). joshua.millstein@usc.edu Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Detecting small holes in packages
Kronberg, J.W.; Cadieux, J.R.
1996-03-19
A package containing a tracer gas, and a method for determining the presence of a hole in the package by sensing the presence of the gas outside the package are disclosed. The preferred tracer gas, especially for food packaging, is sulfur hexafluoride. A quantity of the gas is added to the package and the package is closed. The concentration of the gas in the atmosphere outside the package is measured and compared to a predetermined value of the concentration of the gas in the absence of the package. A measured concentration greater than the predetermined value indicates the presence of a hole in the package. Measuring may be done in a chamber having a lower pressure than that in the package. 3 figs.
A suite of R packages for web-enabled modeling and analysis of surface waters
NASA Astrophysics Data System (ADS)
Read, J. S.; Winslow, L. A.; Nüst, D.; De Cicco, L.; Walker, J. I.
2014-12-01
Researchers often create redundant methods for downloading, manipulating, and analyzing data from online resources. Moreover, the reproducibility of science can be hampered by complicated and voluminous data, lack of time for documentation and long-term maintenance of software, and fear of exposing programming skills. The combination of these factors can encourage unshared one-off programmatic solutions instead of openly provided reusable methods. Federal and academic researchers in the water resources and informatics domains have collaborated to address these issues. The result of this collaboration is a suite of modular R packages that can be used independently or as elements in reproducible analytical workflows. These documented and freely available R packages were designed to fill basic needs for the effective use of water data: the retrieval of time-series and spatial data from web resources (dataRetrieval, geoknife), performing quality assurance and quality control checks of these data with robust statistical methods (sensorQC), the creation of useful data derivatives (including physically- and biologically-relevant indices; GDopp, LakeMetabolizer), and the execution and evaluation of models (glmtools, rLakeAnalyzer). Here, we share details and recommendations for the collaborative coding process, and highlight the benefits of an open-source tool development pattern with a popular programming language in the water resources discipline (such as R). We provide examples of reproducible science driven by large volumes of web-available data using these tools, explore benefits of accessing packages as standardized web processing services (WPS) and present a working platform that allows domain experts to publish scientific algorithms in a service-oriented architecture (WPS4R). We assert that in the era of open data, tools that leverage these data should also be freely shared, transparent, and developed in an open innovation environment.
Vasile, Cornelia; Sivertsvik, Morten; Miteluţ, Amalia Carmen; Brebu, Mihai Adrian; Stoleru, Elena; Rosnes, Jan Thomas; Tănase, Elisabeta Elena; Khan, Waqas; Pamfil, Daniela; Cornea, Călina Petruţa; Irimia, Anamaria; Popa, Mona Elena
2017-01-07
The antifungal, antibacterial, and antioxidant activity of four commercial essential oils (EOs) (thyme, clove, rosemary, and tea tree) from Romanian production were studied in order to assess them as bioactive compounds for active food packaging applications. The chemical composition of the oils was determined with the Folin-Ciocâlteu method and gas chromatography coupled with mass spectrometry and flame ionization detectors, and it was found that they respect the AFNOR/ISO standard limits. The EOs were tested against three food spoilage fungi- Fusarium graminearum , Penicillium corylophilum, and Aspergillus brasiliensis -and three potential pathogenic food bacteria- Staphylococcus aureus , Escherichia coli, and Listeria monocytogenes -using the disc diffusion method. It was found that the EOs of thyme, clove, and tea tree can be used as antimicrobial agents against the tested fungi and bacteria, thyme having the highest inhibitory effect. Concerning antioxidant activity determined by 2,2-diphenyl-1-picrylhydrazyl (DPPH) and 2,2'-azino-bis 3-ethylbenzthiazoline-6-sulfonic acid (ABTS) methods, it has been established that the clove oil exhibits the highest activity because of its high phenolic content. Promising results were obtained by their incorporation into chitosan emulsions and films, which show potential for food packaging. Therefore, these essential oils could be suitable alternatives to chemical additives, satisfying the consumer demand for naturally preserved food products ensuring its safety.
Vasile, Cornelia; Sivertsvik, Morten; Miteluţ, Amalia Carmen; Brebu, Mihai Adrian; Stoleru, Elena; Rosnes, Jan Thomas; Tănase, Elisabeta Elena; Khan, Waqas; Pamfil, Daniela; Cornea, Călina Petruţa; Irimia, Anamaria; Popa, Mona Elena
2017-01-01
The antifungal, antibacterial, and antioxidant activity of four commercial essential oils (EOs) (thyme, clove, rosemary, and tea tree) from Romanian production were studied in order to assess them as bioactive compounds for active food packaging applications. The chemical composition of the oils was determined with the Folin–Ciocâlteu method and gas chromatography coupled with mass spectrometry and flame ionization detectors, and it was found that they respect the AFNOR/ISO standard limits. The EOs were tested against three food spoilage fungi—Fusarium graminearum, Penicillium corylophilum, and Aspergillus brasiliensis—and three potential pathogenic food bacteria—Staphylococcus aureus, Escherichia coli, and Listeria monocytogenes—using the disc diffusion method. It was found that the EOs of thyme, clove, and tea tree can be used as antimicrobial agents against the tested fungi and bacteria, thyme having the highest inhibitory effect. Concerning antioxidant activity determined by 2,2-diphenyl-1-picrylhydrazyl (DPPH) and 2,2’-azino-bis 3-ethylbenzthiazoline-6-sulfonic acid (ABTS) methods, it has been established that the clove oil exhibits the highest activity because of its high phenolic content. Promising results were obtained by their incorporation into chitosan emulsions and films, which show potential for food packaging. Therefore, these essential oils could be suitable alternatives to chemical additives, satisfying the consumer demand for naturally preserved food products ensuring its safety. PMID:28772407
Nural Yilgor; Coskun Kose; Evren Terzi; Aysel Kanturk Figen; Rebecca Ibach; S. Nami Kartal; Sabriye Piskin
2014-01-01
Manufacturing panels from Tetra Pak® (TP) packaging material might be an alternative to conventional wood-based panels. This study evaluated some chemical and physical properties as well as biological, weathering, and fire performance of panels with and without zinc borate (ZnB) by using shredded TP packaging cartons. Such packaging material, a worldwide well-known...
ERIC Educational Resources Information Center
Northwest Regional Educational Lab., Portland, OR.
This document consists of 170 microcomputer software package evaluations prepared by the MicroSIFT (Microcomputer Software and Information for Teachers) Clearinghouse at the Northwest Regional Education Laboratory. Set 11 consists of 37 packages. Set 12 consists of 34 packages. A special unnumbered set, entitled LIBRA Reviews, treats 99 packages…
Geometrical optimization of sensors for eddy currents nondestructive testing and evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thollon, F.; Burais, N.
1995-05-01
Design of Non Destructive Testing (NDT) and Non Destructive Evaluation (NDE) sensors is possible by solving Maxwell`s relations with FEM or BIM. But the large number of geometrical and electrical parameters of sensor and tested material implies many results that don`t give necessarily a well adapted sensor. The authors have used a genetic algorithm for automatic optimization. After having tested this algorithm with analytical solution of Maxwell`s relations for cladding thickness measurement, the method has been implemented in finite element package.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1989-12-01
In the Report of the Senate Committee on Appropriations accompanying the Energy and Water Appropriation Act for 1989, the Committee directed the Department of Energy (DOE) to evaluate the use of lead in the waste packages to be used in geologic repositories for spent nuclear fuel and high-level waste. The evaluation that was performed in response to this directive is presented in this report. This evaluation was based largely on a review of the technical literature on the behavior of lead, reports of work conducted in other countries, and work performed for the waste-management program being conducted by the DOE.more » The initial evaluation was limited to the potential use of lead in the packages to be used in the repository. Also, the focus of this report is post closure performance and not on retrievability and handling aspects of the waste package. 100 refs., 8 figs., 15 tabs.« less
A study of commuter airplane design optimization
NASA Technical Reports Server (NTRS)
Keppel, B. V.; Eysink, H.; Hammer, J.; Hawley, K.; Meredith, P.; Roskam, J.
1978-01-01
The usability of the general aviation synthesis program (GASP) was enhanced by the development of separate computer subroutines which can be added as a package to this assembly of computerized design methods or used as a separate subroutine program to compute the dynamic longitudinal, lateral-directional stability characteristics for a given airplane. Currently available analysis methods were evaluated to ascertain those most appropriate for the design functions which the GASP computerized design program performs. Methods for providing proper constraint and/or analysis functions for GASP were developed as well as the appropriate subroutines.
2014-01-01
Background Performance measures are often neglected during the transition period of national health insurance scheme implementation in many low and middle income countries. These measurements evaluate the extent to which various aspects of the schemes meet their key objectives. This study assesses the implementation of a health insurance scheme using optimal resource use domains and examines possible factors that influence each domain, according to providers’ perspectives. Methods A retrospective, cross-sectional survey was done between August and December 2010 in Kaduna state, and 466 health care provider personnel were interviewed. Optimal-resource-use was defined in four domains: provider payment mechanism (capitation and fee-for-service payment methods), benefit package, administrative efficiency, and active monitoring mechanism. Logistic regression analysis was used to identify provider factors that may influence each domain. Results In the provider payment mechanism domain, capitation payment method (95%) performed better than fee-for-service payment method (62%). Benefit package domain performed strongly (97%), while active monitoring mechanism performed weakly (37%). In the administrative efficiency domain, both promptness of referral system (80%) and prompt arrival of funds (93%) performed well. At the individual level, providers with fewer enrolees encountered difficulties with reimbursement. Other factors significantly influenced each of the optimal-resource-use domains. Conclusions Fee-for-service payment method and claims review, in the provider payment and active monitoring mechanisms, respectively, performed weakly according to the providers’ (at individual-level) perspectives. A short-fall on the supply-side of health insurance could lead to a direct or indirect adverse effect on the demand-side of the scheme. Capitation payment per enrolees should be revised to conform to economic circumstances. Performance indicators and providers’ characteristics and experiences associated with resource use can assist policy makers to monitor and evaluate health insurance implementation. PMID:24628889
Efficacy of Multimedia Package in Communicative Skill in English
ERIC Educational Resources Information Center
Singaravelu, G.
2014-01-01
The study enlightens the effectiveness of Multimedia Package in learning communicative skill in English. Objectives of the study: To prepare a Multimedia Package for developing communicative skill in English. To find out the impact of Multimedia Package in improving communicative skill in English. Quasi Experimental method was adopted in the…
Damgaard, Rasmus; Rasmussen, Mats; Buus, Peter; Mulhall, Brian; Guazzo, Dana Morton
2013-01-01
In Part 1 of this three-part research series, a leak test performed using high-voltage leak detection (HVLD) technology, also referred to as an electrical conductivity and capacitance leak test, was developed and validated for container-closure integrity verification of a small-volume laminate plastic bag containing an aqueous solution for injection. The sterile parenteral product is the rapid-acting insulin analogue, insulin aspart (NovoRapid®/NovoLog®, by Novo Nordisk A/S, Bagsværd, Denmark). The aseptically filled and sealed package is designed to preserve product sterility through expiry. Method development and validation work incorporated positive control packages with a single hole laser-drilled through the laminate film of each bag. A unique HVLD method characterized by specific high-voltage and potentiometer set points was established for testing bags positioned in each of three possible orientations as they are conveyed through the instrument's test zone in each of two possible directions-resulting in a total of six different test method options. Validation study results successfully demonstrated the ability of all six methods to accurately and reliably detect those packages with laser-drilled holes from 2.5-11.2 μm in nominal diameter. Part 2 of this series will further explore HVLD test results as a function of package seal and product storage variables. The final Part 3 will report the impact of HVLD exposure on product physico-chemical stability. In this Part 1 of a three-part research series, a leak test method based on electrical conductivity and capacitance, called high voltage leak detection (HVLD), was used to find leaks in small plastic bags filled with an insulin pharmaceutical solution for human injection by Novo Nordisk A/S (Bagsværd, Denmark). To perform the test, the package is electrically grounded while being conveyed past an electrode linked to a high-voltage, low-amperage transformer. The instrument measures the current that passes from the transformer to the electrode, through the packaged product and along the package walls, to the ground. Plastic packages without defect are relatively nonconductive and yield a low voltage reading; a leaking package with electrically conductive solution located in or near the leak triggers a spike in voltage reading. Test methods were optimized and validated, enabling the detection of leaking packages with holes as small as 2.5 μm in diameter. Part 2 of this series will further explore HVLD test results as a function of package seal and product storage variables. The final Part 3 will report the impact of HVLD exposure on product stability.
Laboratory Connections: Review of Two Commercial Interfacing Packages.
ERIC Educational Resources Information Center
Powers, Michael H.
1989-01-01
Evaluates two Apple II interfacing packages designed to measure pH: (1) "Experiments in Chemistry" by HRM Software and (2) "Voltage Plotter III" by Vernier Software. Provides characteristics and screen dumps of each package. Reports both systems are suitable for high school or beginning college laboratories. (MVL)
Packaging of microwave integrated circuits operating beyond 100 GHz
NASA Technical Reports Server (NTRS)
Samoska, L.; Daniel, E.; Sokolov, V.; Sommerfeldt, S.; Bublitz, J.; Olson, K.; Gilbert, B.; Chow, D.
2002-01-01
Several methods of packaging high speed (75-330 GHz) InP HEMT MMIC devices are discussed. Coplanar wirebonding is presented with measured insertion loss of less than 0.5dB and return loss better than -17 dB from DC to 110 GHz. A motherboard/daughterboard packaging scheme is presented which supports minimum loss chains of MMICs using this coplanar wirebonding method. Split waveguide block packaging approaches are presented in G-band (140-220 GHz) with two types of MMIC-waveguide transitions: E-plane probe andantipodal finline.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rule, K.; Scott, J.; Larson, S.
1995-12-31
The Tokamak Fusion Test Reactor (TFTR) is a one-of-a kind tritium fusion research reactor, and is planned to be decommissioned within the next several years. This is the largest fusion reactor in the world and as a result of deuterium-tritum reactions is tritium contaminated and activated from 14 Mev neutrons. This presents many unusual challenges when dismantling, packaging and disposing its components and ancillary systems. Special containers are being designed to accommodate the vacuum vessel, neutral beams, and tritium delivery and processing systems. A team of experienced professionals performed a detailed field study to evaluate the requirements and appropriate methodsmore » for packaging the radioactive materials. This team focused on several current and innovative methods for waste minimization that provides the oppurtunmost cost effective manner to package and dispose of the waste. This study also produces a functional time-phased schedule which conjoins the waste volume, weight, costs and container requirements with the detailed project activity schedule for the entire project scope. This study and project will be the first demonstration of the decommissioning of a tritium fusion test reactor. The radioactive waste disposal aspects of this project are instrumental in demonstrating the viability of a fusion power reactor with regard to its environmental impact and ultimate success.« less
Fujiwara, Yasuhiro; Fujioka, Hitoshi; Watanabe, Tomoko; Sekiguchi, Maiko; Murakami, Ryuji
2017-09-01
Confirmation of the magnetic resonance (MR) compatibility of implanted medical devices (IMDs) is mandatory before conducting magnetic resonance imaging (MRI) examinations. In Japan, few such confirmation methods are in use, and they are time-consuming. This study aimed to develop a Web-based searchable MR safety information system to confirm IMD compatibility and to evaluate the usefulness of the system. First, MR safety information for intravascular stents and stent grafts sold in Japan was gathered by interviewing 20 manufacturers. These IMDs were categorized based on the descriptions available on medical package inserts as: "MR Safe," "MR Conditional," "MR Unsafe," "Unknown," and "No Medical Package Insert Available". An MR safety information database for implants was created based on previously proposed item lists. Finally, a Web-based searchable system was developed using this database. A questionnaire was given to health-care personnel in Japan to evaluate the usefulness of this system. Seventy-nine datasets were collected using information provided by 12 manufacturers and by investigating the medical packaging of the IMDs. Although the datasets must be updated by collecting data from other manufacturers, this system facilitates the easy and rapid acquisition of MR safety information for IMDs, thereby improving the safety of MRI examinations.
2006-06-29
KENNEDY SPACE CENTER, FLA. - In the Operations and Checkout Building, Michele Perchonok stows packages of food that the STS-121 crew will eat on the 12-day mission. Perchonok is a NASA Subsystem manager for Shuttle Food Systems from Johnson Space Center. Astronauts select their own menus from a large array of food items. Astronauts are supplied with three balanced meals, plus snacks. Diets are designed to supply each astronaut with 100 percent of the daily value of vitamins and minerals necessary for the environment of space. Foods flown on space missions are researched and developed at the Space Food Systems Laboratory at the Johnson Space Center (JSC) in Houston, which is staffed by food scientists, dietitians and engineers. Foods are analyzed through nutritional analysis, sensory evaluation, storage studies, packaging evaluations and many other methods. Each astronaut’s food is stored aboard the space shuttle and is identified by a colored dot affixed to each package. A supplementary food supply (pantry) consisting of two extra days per person is stowed aboard the space shuttle for each flight. Pantry items are flown in addition to the menu in case the flight is unexpectedly extended because of bad weather at the landing site or for some other unforeseen reason. Photo credit: NASA/Kim Shiflett
2006-06-29
KENNEDY SPACE CENTER, FLA. - In the Operations and Checkout Building, Michele Perchonok closes a container of food packages that the STS-121 crew will eat on the 12-day mission. Perchonok is a NASA Subsystem manager for Shuttle Food Systems from Johnson Space Center. Astronauts select their own menus from a large array of food items. Astronauts are supplied with three balanced meals, plus snacks. Diets are designed to supply each astronaut with 100 percent of the daily value of vitamins and minerals necessary for the environment of space. Foods flown on space missions are researched and developed at the Space Food Systems Laboratory at the Johnson Space Center (JSC) in Houston, which is staffed by food scientists, dietitians and engineers. Foods are analyzed through nutritional analysis, sensory evaluation, storage studies, packaging evaluations and many other methods. Each astronaut’s food is stored aboard the space shuttle and is identified by a colored dot affixed to each package. A supplementary food supply (pantry) consisting of two extra days per person is stowed aboard the space shuttle for each flight. Pantry items are flown in addition to the menu in case the flight is unexpectedly extended because of bad weather at the landing site or for some other unforeseen reason. Photo credit: NASA/Kim Shiflett
2006-06-29
KENNEDY SPACE CENTER, FLA. - In the Operations and Checkout Building, Michele Perchonok stows packages of food that the STS-121 crew will eat on the 12-day mission. Perchonok is a NASA Subsystem manager for Shuttle Food Systems from Johnson Space Center. Astronauts select their own menus from a large array of food items. Astronauts are supplied with three balanced meals, plus snacks. Diets are designed to supply each astronaut with 100 percent of the daily value of vitamins and minerals necessary for the environment of space. Foods flown on space missions are researched and developed at the Space Food Systems Laboratory at the Johnson Space Center (JSC) in Houston, which is staffed by food scientists, dietitians and engineers. Foods are analyzed through nutritional analysis, sensory evaluation, storage studies, packaging evaluations and many other methods. Each astronaut’s food is stored aboard the space shuttle and is identified by a colored dot affixed to each package. A supplementary food supply (pantry) consisting of two extra days per person is stowed aboard the space shuttle for each flight. Pantry items are flown in addition to the menu in case the flight is unexpectedly extended because of bad weather at the landing site or for some other unforeseen reason. Photo credit: NASA/Kim Shiflett
Food Companies’ Calorie-Reduction Pledges to Improve U.S. Diet
Slining, Meghan M.; Ng, Shu Wen; Popkin, Barry M.
2013-01-01
Heretofore, corporate voluntary pledges to improve the health of Americans have been linked neither to explicit measurable commitments nor to a framework for an independent evaluation. The Healthy Weight Commitment Foundation (HWCF), whose members include 16 of the nation’s leading consumer packaged goods food and beverage manufacturers, voluntarily pledged to collectively remove 1 trillion calories from their products by 2012 (against a 2007 baseline), and 1.5 trillion calories by 2015. The pledge is designed to reduce the calorie gap commensurate with the HWCF companies’ role in the U.S. diet. To date, no system exists for documenting the nutritional and public health impacts of industry-led changes in the food supply on individual diets. The current study represents a unique opportunity to understand how the consumer packaged goods food and beverage sector is changing and how these changes are associated with changes in the American diet. It presents data on national caloric sales from this sector, purchases of these goods by various subpopulations, and methods linking these to individual intakes of Americans. Findings show that HWCF companies accounted for approximately 25% of calories consumed in the U.S. in 2007 and that the 1.5 trillion–calorie pledge (about 14 calories/day/capita) accounts for 0.8% of the calories sold across all consumer packaged goods food and beverage brands in 2007. The authors hope that this evaluation will continue to create models and methods for demonstrating the effects of changes in the food supply on individual diets, particularly among those from vulnerable subpopulations. PMID:23332336
Developing a Virtual Physics World
ERIC Educational Resources Information Center
Wegener, Margaret; McIntyre, Timothy J.; McGrath, Dominic; Savage, Craig M.; Williamson, Michael
2012-01-01
In this article, the successful implementation of a development cycle for a physics teaching package based on game-like virtual reality software is reported. The cycle involved several iterations of evaluating students' use of the package followed by instructional and software development. The evaluation used a variety of techniques, including…
Sensory impacts of food-packaging interactions.
Duncan, Susan E; Webster, Janet B
2009-01-01
Sensory changes in food products result from intentional or unintentional interactions with packaging materials and from failure of materials to protect product integrity or quality. Resolving sensory issues related to plastic food packaging involves knowledge provided by sensory scientists, materials scientists, packaging manufacturers, food processors, and consumers. Effective communication among scientists and engineers from different disciplines and industries can help scientists understand package-product interactions. Very limited published literature describes sensory perceptions associated with food-package interactions. This article discusses sensory impacts, with emphasis on oxidation reactions, associated with the interaction of food and materials, including taints, scalping, changes in food quality as a function of packaging, and examples of material innovations for smart packaging that can improve sensory quality of foods and beverages. Sensory evaluation is an important tool for improved package selection and development of new materials.
A graph-theoretic method to quantify the airline route authority
NASA Technical Reports Server (NTRS)
Chan, Y.
1979-01-01
The paper introduces a graph-theoretic method to quantify the legal statements in route certificate which specifies the airline routing restrictions. All the authorized nonstop and multistop routes, including the shortest time routes, can be obtained, and the method suggests profitable route structure alternatives to airline analysts. This method to quantify the C.A.B. route authority was programmed in a software package, Route Improvement Synthesis and Evaluation, and demonstrated in a case study with a commercial airline. The study showed the utility of this technique in suggesting route alternatives and the possibility of improvements in the U.S. route system.
Kern-Dunlap, L; Dunlap, G; Clarke, S; Childs, K E; White, R L; Stewart, M P
1992-01-01
Peer interactions are among the greatest challenges experienced by children who have severe emotional and behavioral problems. This study evaluated an intervention package designed to increase the ratio of these children's desirable to undesirable interactions. The package included three principal components: (a) observation of videotapes following regularly scheduled peer activity sessions; (b) self-evaluation of the children's peer interactions observed on the videotapes; and (c) delayed feedback and reinforcement for desirable peer interactions. Five students from two elementary schools participated. Multiple baseline designs and one reversal were used to evaluate the effects of the intervention package. The results showed that the intervention produced lower levels of undesirable peer interactions and higher ratios of desirable to undesirable interactions for all participants. The results are discussed in regard to their conceptual and applied implications and in terms of specific directions for future research. PMID:1634428
Reference datasets for bioequivalence trials in a two-group parallel design.
Fuglsang, Anders; Schütz, Helmut; Labes, Detlew
2015-03-01
In order to help companies qualify and validate the software used to evaluate bioequivalence trials with two parallel treatment groups, this work aims to define datasets with known results. This paper puts a total 11 datasets into the public domain along with proposed consensus obtained via evaluations from six different software packages (R, SAS, WinNonlin, OpenOffice Calc, Kinetica, EquivTest). Insofar as possible, datasets were evaluated with and without the assumption of equal variances for the construction of a 90% confidence interval. Not all software packages provide functionality for the assumption of unequal variances (EquivTest, Kinetica), and not all packages can handle datasets with more than 1000 subjects per group (WinNonlin). Where results could be obtained across all packages, one showed questionable results when datasets contained unequal group sizes (Kinetica). A proposal is made for the results that should be used as validation targets.
Bonekamp, S; Ghosh, P; Crawford, S; Solga, S F; Horska, A; Brancati, F L; Diehl, A M; Smith, S; Clark, J M
2008-01-01
To examine five available software packages for the assessment of abdominal adipose tissue with magnetic resonance imaging, compare their features and assess the reliability of measurement results. Feature evaluation and test-retest reliability of softwares (NIHImage, SliceOmatic, Analyze, HippoFat and EasyVision) used in manual, semi-automated or automated segmentation of abdominal adipose tissue. A random sample of 15 obese adults with type 2 diabetes. Axial T1-weighted spin echo images centered at vertebral bodies of L2-L3 were acquired at 1.5 T. Five software packages were evaluated (NIHImage, SliceOmatic, Analyze, HippoFat and EasyVision), comparing manual, semi-automated and automated segmentation approaches. Images were segmented into cross-sectional area (CSA), and the areas of visceral (VAT) and subcutaneous adipose tissue (SAT). Ease of learning and use and the design of the graphical user interface (GUI) were rated. Intra-observer accuracy and agreement between the software packages were calculated using intra-class correlation. Intra-class correlation coefficient was used to obtain test-retest reliability. Three of the five evaluated programs offered a semi-automated technique to segment the images based on histogram values or a user-defined threshold. One software package allowed manual delineation only. One fully automated program demonstrated the drawbacks of uncritical automated processing. The semi-automated approaches reduced variability and measurement error, and improved reproducibility. There was no significant difference in the intra-observer agreement in SAT and CSA. The VAT measurements showed significantly lower test-retest reliability. There were some differences between the software packages in qualitative aspects, such as user friendliness. Four out of five packages provided essentially the same results with respect to the inter- and intra-rater reproducibility. Our results using SliceOmatic, Analyze or NIHImage were comparable and could be used interchangeably. Newly developed fully automated approaches should be compared to one of the examined software packages.
Bonekamp, S; Ghosh, P; Crawford, S; Solga, SF; Horska, A; Brancati, FL; Diehl, AM; Smith, S; Clark, JM
2009-01-01
Objective To examine five available software packages for the assessment of abdominal adipose tissue with magnetic resonance imaging, compare their features and assess the reliability of measurement results. Design Feature evaluation and test–retest reliability of softwares (NIHImage, SliceOmatic, Analyze, HippoFat and EasyVision) used in manual, semi-automated or automated segmentation of abdominal adipose tissue. Subjects A random sample of 15 obese adults with type 2 diabetes. Measurements Axial T1-weighted spin echo images centered at vertebral bodies of L2–L3 were acquired at 1.5 T. Five software packages were evaluated (NIHImage, SliceOmatic, Analyze, HippoFat and EasyVision), comparing manual, semi-automated and automated segmentation approaches. Images were segmented into cross-sectional area (CSA), and the areas of visceral (VAT) and subcutaneous adipose tissue (SAT). Ease of learning and use and the design of the graphical user interface (GUI) were rated. Intra-observer accuracy and agreement between the software packages were calculated using intra-class correlation. Intra-class correlation coefficient was used to obtain test–retest reliability. Results Three of the five evaluated programs offered a semi-automated technique to segment the images based on histogram values or a user-defined threshold. One software package allowed manual delineation only. One fully automated program demonstrated the drawbacks of uncritical automated processing. The semi-automated approaches reduced variability and measurement error, and improved reproducibility. There was no significant difference in the intra-observer agreement in SAT and CSA. The VAT measurements showed significantly lower test–retest reliability. There were some differences between the software packages in qualitative aspects, such as user friendliness. Conclusion Four out of five packages provided essentially the same results with respect to the inter- and intra-rater reproducibility. Our results using SliceOmatic, Analyze or NIHImage were comparable and could be used interchangeably. Newly developed fully automated approaches should be compared to one of the examined software packages. PMID:17700582
Nutrition. Learning Activity Package.
ERIC Educational Resources Information Center
Lee, Carolyn
This learning activity package on nutrition is one of a series of 12 titles developed for use in health occupations education programs. Materials in the package include objectives, a list of materials needed, a list of definitions, information sheets, reviews (self evaluations) of portions of the content, and answers to reviews. These topics are…
Shock & Anaphylactic Shock. Learning Activity Package.
ERIC Educational Resources Information Center
Hime, Kirsten
This learning activity package on shock and anaphylactic shock is one of a series of 12 titles developed for use in health occupations education programs. Materials in the package include objectives, a list of materials needed, information sheets, reviews (self evaluations) of portions of the content, and answers to reviews. These topics are…
Solar water heater design package
NASA Technical Reports Server (NTRS)
1981-01-01
Package describes commercial domestic-hot-water heater with roof or rack mounted solar collectors. System is adjustable to pre-existing gas or electric hot-water house units. Design package includes drawings, description of automatic control logic, evaluation measurements, possible design variations, list of materials and installation tools, and trouble-shooting guide and manual.
USDA-ARS?s Scientific Manuscript database
Polystyrene is one of the most widely used plastics in the manufacture of packaging materials. Extruded polystyrene foam is commonly sold under the trademark name of StyrofoamTM. Polystyrene packaging is a multibillion dollar a year industry. Since polystyrene is non-biodegradable, a biodegradable m...
Oral Hygiene. Learning Activity Package.
ERIC Educational Resources Information Center
Hime, Kirsten
This learning activity package on oral hygiene is one of a series of 12 titles developed for use in health occupations education programs. Materials in the package include objectives, a list of materials needed, a list of definitions, information sheets, reviews (self evaluations) of portions of the content, and answers to reviews. These topics…
Grooming. Learning Activity Package.
ERIC Educational Resources Information Center
Stark, Pamela
This learning activity package on grooming for health workers is one of a series of 12 titles developed for use in health occupations education programs. Materials in the package include objectives, a list of materials needed, information sheets, reviews (self evaluations) of portions of the content, and answers to reviews. These topics are…
Development of a qualification standard for adhesives used in hybrid microcircuits
NASA Technical Reports Server (NTRS)
Licari, J. J.; Weigand, B. L.; Soykin, C. A.
1981-01-01
Improved qualification standards and test procedures for adhesives used in microelectronic packaging are developed. The test methods in specification for the Selection and Use of Organic Adhesives in Hybrid Microcircuits are reevaluated versus industry and government requirements. Four electrically insulative and four electrically conductive adhesives used in the assembly of hybrid microcircuits are selected to evaluate the proposed revised test methods. An estimate of the cost to perform qualification testing of an adhesive to the requirements of the revised specification is also prepared.
Application of Thermo-Mechanical Measurements of Plastic Packages for Reliability Evaluation of PEMS
NASA Technical Reports Server (NTRS)
Sharma, Ashok K.; Teverovsky, Alexander
2004-01-01
Thermo-mechanical analysis (TMA) is typically employed for measurements of the glass transition temperature (Tg) and coefficients of thermal expansion (CTE) in molding compounds used in plastic encapsulated microcircuits (PEMs). Application of TMA measurements directly to PEMs allows anomalies to be revealed in deformation of packages with temperature, and thus indicates possible reliability concerns related to thermo-mechanical integrity and stability of the devices. In this work, temperature dependencies of package deformation were measured in several types of PEMs that failed environmental stress testing including temperature cycling, highly accelerated stress testing (HAST) in humid environments, and bum-in (BI) testing. Comparison of thermo-mechanical characteristics of packages and molding compounds in the failed parts allowed for explanation of the observed failures. The results indicate that TMA of plastic packages might be used for quality evaluation of PEMs intended for high-reliability applications.
Rezaeigolestani, Mohammadreza; Misaghi, Ali; Khanjari, Ali; Basti, Afshin Akhondzadeh; Abdulkhani, Ali; Fayazfar, Samira
2017-11-02
Biodegradability and antimicrobial activity of food packaging materials are among the most attractive parameters in modern food industries. In order to develop biodegradable poly-lactic acid (PLA) film to antibacterial nanocomposites, different concentration of Zataria multiflora Bioss. essential oil (ZME), propolis ethanolic extract (PEE) and cellulose nanofiber (CNF) were incorporated to the polymer by solvent casting method. The resulting films were characterized by mechanical and physical tests and their antimicrobial application was evaluated in-vitro against four common foodborne pathogens and in vacuum-packed cooked sausages during refrigerated storage. Mechanical examination revealed that addition of ZME and PEE made films more flexible and incorporation of CNF improved almost all mechanical parameters tested. Moreover, according to physical analysis, incorporation of 0.5% v/v ZME to the composite primary solutions improved water vapor permeability of the resulting films. Almost all of the active films were effective against the tested bacteria except for PLA/PEE films, and maximum antibacterial effects recorded for the films containing both ZME and PEE. Based on the microbiological and sensory evaluation of the sausages, all of the PLA/1%ZME/PEE composites increased the shelf life to >40days. The results indicate that incorporation of natural antimicrobial substances such as ZME and PEE to packaging material could be an interesting approach in development of active packaging material without significant negative effect on polymer technical properties. Copyright © 2017 Elsevier B.V. All rights reserved.
Cegielska-Radziejewska, Renata; Pikul, Jan
2004-03-01
The aim of this study was to determine the effect of sodium lactate addition on shelf-life extension of sliced poultry sausage packaged both in air and nitrogen atmospheres and stored in refrigerated conditions. Basic chemical composition, pH, and malonaldehyde content were assayed and color measurement using the reflection method was carried out. Microbiological examination consisted of determination of total number of aerobic psychrotrophic bacteria and number of lactic acid bacteria. Sensory evaluation of products was performed. Microbiological and sensory quality of sliced poultry meat sausage was dependent on the addition during production of sodium lactate and the composition of gases (air or nitrogen) used in packaging. Slices of poultry sausage with 1% as well as 2% of sodium lactate maintained their initial quality of evaluated sensory attributes longer, irrespective of the applied gases. Sodium lactate inhibited growth of aerobic psychrotrophic bacteria and lactic acid bacteria during refrigerated storage. Sodium lactate also inhibited the formation of malonaldehyde in sliced poultry sausage during refrigerated storage. The effectiveness of this process depended on the concentration of sodium lactate addition. It was concluded that 1% as well as 2% addition of sodium lactate could extend the shelf life of sliced poultry sausage packaged in air atmosphere and stored at 5 to 7 degrees C by 3 or 4 times, respectively. Sliced poultry sausage treated with 2% sodium lactate packed in nitrogen had the longest (35-day) shelf life. This was a sevenfold increase in the shelf life of sliced poultry sausage compared with the control.
1980-06-01
courseware package on how to program lessons for an automated system. Since PLANIT (Programming Language for Interactive Teaching) is the student/author...assisted instruction (CAI), how to program PLANIT lessons, and to evaluate the effectiveness of the package for select Army users. The resultant courseware
USDA-ARS?s Scientific Manuscript database
The insect growth regulator methoprene has been impregnated onto various packaging materials to control stored product insects, and is labeled for use in this manner in the United States. Different methodologies were utilized to evaluate efficacy towards Tribolium castaneum (Herbst), the red flour b...
Method of forming a package for MEMS-based fuel cell
Morse, Jeffrey D; Jankowski, Alan F
2013-05-21
A MEMS-based fuel cell package and method thereof is disclosed. The fuel cell package comprises seven layers: (1) a sub-package fuel reservoir interface layer, (2) an anode manifold support layer, (3) a fuel/anode manifold and resistive heater layer, (4) a Thick Film Microporous Flow Host Structure layer containing a fuel cell, (5) an air manifold layer, (6) a cathode manifold support structure layer, and (7) a cap. Fuel cell packages with more than one fuel cell are formed by positioning stacks of these layers in series and/or parallel. The fuel cell package materials such as a molded plastic or a ceramic green tape material can be patterned, aligned and stacked to form three dimensional microfluidic channels that provide electrical feedthroughs from various layers which are bonded together and mechanically support a MEMS-based miniature fuel cell. The package incorporates resistive heating elements to control the temperature of the fuel cell stack. The package is fired to form a bond between the layers and one or more microporous flow host structures containing fuel cells are inserted within the Thick Film Microporous Flow Host Structure layer of the package.
Method of forming a package for mems-based fuel cell
Morse, Jeffrey D.; Jankowski, Alan F.
2004-11-23
A MEMS-based fuel cell package and method thereof is disclosed. The fuel cell package comprises seven layers: (1) a sub-package fuel reservoir interface layer, (2) an anode manifold support layer, (3) a fuel/anode manifold and resistive heater layer, (4) a Thick Film Microporous Flow Host Structure layer containing a fuel cell, (5) an air manifold layer, (6) a cathode manifold support structure layer, and (7) a cap. Fuel cell packages with more than one fuel cell are formed by positioning stacks of these layers in series and/or parallel. The fuel cell package materials such as a molded plastic or a ceramic green tape material can be patterned, aligned and stacked to form three dimensional microfluidic channels that provide electrical feedthroughs from various layers which are bonded together and mechanically support a MEMOS-based miniature fuel cell. The package incorporates resistive heating elements to control the temperature of the fuel cell stack. The package is fired to form a bond between the layers and one or more microporous flow host structures containing fuel cells are inserted within the Thick Film Microporous Flow Host Structure layer of the package.
Raines, Christopher R; Hunt, Melvin C
2010-01-01
Carboxymyoglobin (COMb) development of beef Longissimus lumborum as related to molecular CO availability and package headspace volume was evaluated. Steaks from six pairs of USDA Select strip loins were packaged in modified atmosphere packages with 0.2%, 0.4%, or 0.8% CO and 30% CO(2) and balanced with N(2) to obtain meat-to-gas ratios of 0.4, 0.7, and 1.1, and CO molar concentrations of 0.07, 0.10, and 0.20 mMol. Steak redness (CIE a*), COMb layer thickness, percentage of CO in the headspace, visual display color, and bloom intensity scores were evaluated 4 and 7 d after packaging. Greater concentration of CO in a smaller headspace resulted in a thicker COMb layer compared with lesser concentration of CO in a larger headspace, regardless of moles CO available. The combined effects of concentration of CO and headspace volume had a greater impact on COMb development than millimoles of CO in the package headspace. Package headspace can be reduced and the concentration of CO can be increased without detriment to fresh beef color or consumer safety.
Jung, Jooyeoun; Wang, Wenjie; McGorrin, Robert J; Zhao, Yanyun
2018-02-01
Moisture adsorption isotherms and storability of dried hazelnut inshells and kernels produced in Oregon were evaluated and compared among cultivars, including Barcelona, Yamhill, and Jefferson. Experimental moisture adsorption data fitted to Guggenheim-Anderson-de Boer (GAB) model, showing less hygroscopic properties in Yamhill than other cultivars of inshells and kernels due to lower content of carbohydrate and protein, but higher content of fat. The safe levels of moisture content (MC, dry basis) of dried inshells and kernels for reaching kernel water activity (a w ) ≤0.65 were estimated using the GAB model as 11.3% and 5.0% for Barcelona, 9.4% and 4.2% for Yamhill, and 10.7% and 4.9% for Jefferson, respectively. Storage conditions (2 °C at 85% to 95% relative humidity [RH], 10 °C at 65% to 75% RH, and 27 °C at 35% to 45% RH), times (0, 4, 8, or 12 mo), and packaging methods (atmosphere vs. vacuum) affected MC, a w , bioactive compounds, lipid oxidation, and enzyme activity of dried hazelnut inshells or kernels. For inshells packaged at woven polypropylene bag, MC and a w of inshells and kernels (inside shells) increased at 2 and 10 °C, but decreased at 27 °C during storage. For kernels, lipid oxidation and polyphenol oxidase activity also increased with extended storage time (P < 0.05), and MC and a w of vacuum packaged samples were more stable during storage than those atmospherically packaged ones. Principal component analysis showed correlation of kernel qualities with storage condition, time, and packaging method. This study demonstrated that the ideal storage condition or packaging method varied among cultivars due to their different moisture adsorption and physicochemical and enzymatic stability during storage. Moisture adsorption isotherm of hazelnut inshells and kernels is useful for predicting the storability of nuts. This study found that water adsorption and storability varied among the different cultivars of nuts, in which Yamhill was less hygroscopic than Barcelona and Jefferson, thus more stable during storage. For ensuring food safety and quality of nuts during storage, each cultivar of kernels should be dried to a certain level of MC. Lipid oxidation and enzyme activity of kernel could be increased with extended storage time. Vacuum packaging was recommended to kernels for reducing moisture adsorption during storage. © 2018 Institute of Food Technologists®.
Protection of microelectronic devices during packaging
Peterson, Kenneth A.; Conley, William R.
2002-01-01
The present invention relates to a method of protecting a microelectronic device during device packaging, including the steps of applying a water-insoluble, protective coating to a sensitive area on the device; performing at least one packaging step; and then substantially removing the protective coating, preferably by dry plasma etching. The sensitive area can include a released MEMS element. The microelectronic device can be disposed on a wafer. The protective coating can be a vacuum vapor-deposited parylene polymer, silicon nitride, metal (e.g. aluminum or tungsten), a vapor deposited organic material, cynoacrylate, a carbon film, a self-assembled monolayered material, perfluoropolyether, hexamethyldisilazane, or perfluorodecanoic carboxylic acid, silicon dioxide, silicate glass, or combinations thereof. The present invention also relates to a method of packaging a microelectronic device, including: providing a microelectronic device having a sensitive area; applying a water-insoluble, protective coating to the sensitive area; providing a package; attaching the device to the package; electrically interconnecting the device to the package; and substantially removing the protective coating from the sensitive area.
Temporary coatings for protection of microelectronic devices during packaging
Peterson, Kenneth A.; Conley, William R.
2005-01-18
The present invention relates to a method of protecting a microelectronic device during device packaging, including the steps of applying a water-insoluble, temporary protective coating to a sensitive area on the device; performing at least one packaging step; and then substantially removing the protective coating, preferably by dry plasma etching. The sensitive area can include a released MEMS element. The microelectronic device can be disposed on a wafer. The protective coating can be a vacuum vapor-deposited parylene polymer, silicon nitride, metal (e.g. aluminum or tungsten), a vapor deposited organic material, cynoacrylate, a carbon film, a self-assembled monolayered material, perfluoropolyether, hexamethyldisilazane, or perfluorodecanoic carboxylic acid, silicon dioxide, silicate glass, or combinations thereof. The present invention also relates to a method of packaging a microelectronic device, including: providing a microelectronic device having a sensitive area; applying a water-insoluble, protective coating to the sensitive area; providing a package; attaching the device to the package; electrically interconnecting the device to the package; and substantially removing the protective coating from the sensitive area.
ATACseqQC: a Bioconductor package for post-alignment quality assessment of ATAC-seq data.
Ou, Jianhong; Liu, Haibo; Yu, Jun; Kelliher, Michelle A; Castilla, Lucio H; Lawson, Nathan D; Zhu, Lihua Julie
2018-03-01
ATAC-seq (Assays for Transposase-Accessible Chromatin using sequencing) is a recently developed technique for genome-wide analysis of chromatin accessibility. Compared to earlier methods for assaying chromatin accessibility, ATAC-seq is faster and easier to perform, does not require cross-linking, has higher signal to noise ratio, and can be performed on small cell numbers. However, to ensure a successful ATAC-seq experiment, step-by-step quality assurance processes, including both wet lab quality control and in silico quality assessment, are essential. While several tools have been developed or adopted for assessing read quality, identifying nucleosome occupancy and accessible regions from ATAC-seq data, none of the tools provide a comprehensive set of functionalities for preprocessing and quality assessment of aligned ATAC-seq datasets. We have developed a Bioconductor package, ATACseqQC, for easily generating various diagnostic plots to help researchers quickly assess the quality of their ATAC-seq data. In addition, this package contains functions to preprocess aligned ATAC-seq data for subsequent peak calling. Here we demonstrate the utilities of our package using 25 publicly available ATAC-seq datasets from four studies. We also provide guidelines on what the diagnostic plots should look like for an ideal ATAC-seq dataset. This software package has been used successfully for preprocessing and assessing several in-house and public ATAC-seq datasets. Diagnostic plots generated by this package will facilitate the quality assessment of ATAC-seq data, and help researchers to evaluate their own ATAC-seq experiments as well as select high-quality ATAC-seq datasets from public repositories such as GEO to avoid generating hypotheses or drawing conclusions from low-quality ATAC-seq experiments. The software, source code, and documentation are freely available as a Bioconductor package at https://bioconductor.org/packages/release/bioc/html/ATACseqQC.html .
puma: a Bioconductor package for propagating uncertainty in microarray analysis.
Pearson, Richard D; Liu, Xuejun; Sanguinetti, Guido; Milo, Marta; Lawrence, Neil D; Rattray, Magnus
2009-07-09
Most analyses of microarray data are based on point estimates of expression levels and ignore the uncertainty of such estimates. By determining uncertainties from Affymetrix GeneChip data and propagating these uncertainties to downstream analyses it has been shown that we can improve results of differential expression detection, principal component analysis and clustering. Previously, implementations of these uncertainty propagation methods have only been available as separate packages, written in different languages. Previous implementations have also suffered from being very costly to compute, and in the case of differential expression detection, have been limited in the experimental designs to which they can be applied. puma is a Bioconductor package incorporating a suite of analysis methods for use on Affymetrix GeneChip data. puma extends the differential expression detection methods of previous work from the 2-class case to the multi-factorial case. puma can be used to automatically create design and contrast matrices for typical experimental designs, which can be used both within the package itself but also in other Bioconductor packages. The implementation of differential expression detection methods has been parallelised leading to significant decreases in processing time on a range of computer architectures. puma incorporates the first R implementation of an uncertainty propagation version of principal component analysis, and an implementation of a clustering method based on uncertainty propagation. All of these techniques are brought together in a single, easy-to-use package with clear, task-based documentation. For the first time, the puma package makes a suite of uncertainty propagation methods available to a general audience. These methods can be used to improve results from more traditional analyses of microarray data. puma also offers improvements in terms of scope and speed of execution over previously available methods. puma is recommended for anyone working with the Affymetrix GeneChip platform for gene expression analysis and can also be applied more generally.
ERIC Educational Resources Information Center
Tsiouri, Ioanna; Simmons, Elizabeth Schoen; Paul, Rhea
2012-01-01
This study evaluates the effectiveness of an intervention package including a discrete trial program (Rapid Motor Imitation Antecedent Training (Tsiouri and Greer, "J Behav Educat" 12:185-206, 2003) combined with parent education for eliciting first words in children with ASD who had little or no spoken language. Evaluation of the approach…
Evaluation of the Field Test of Project Information Packages: Volume III--Resource Cost Analysis.
ERIC Educational Resources Information Center
Al-Salam, Nabeel; And Others
The third of three volumes evaluating the first year field test of the Project Information Packages (PIPs) provides a cost analysis study as a key element in the total evaluation. The resource approach to cost analysis is explained and the specific resource methodology used in the main cost analysis of the 19 PIP field-test projects detailed. The…
ERIC Educational Resources Information Center
Northwest Regional Educational Lab., Portland, OR.
This document consists of 68 microcomputer software package evaluations prepared by MicroSIFT (Microcomputer Software and Information for Teachers) Clearinghouse at the Northwest Regional Education Laboratory. There are 26 packages in set 13 and 42 in set 14. Each software review lists producer, time and place of evaluation, cost, ability level,…
Kim, Yoonsang; Emery, Sherry
2013-01-01
Several statistical packages are capable of estimating generalized linear mixed models and these packages provide one or more of three estimation methods: penalized quasi-likelihood, Laplace, and Gauss-Hermite. Many studies have investigated these methods’ performance for the mixed-effects logistic regression model. However, the authors focused on models with one or two random effects and assumed a simple covariance structure between them, which may not be realistic. When there are multiple correlated random effects in a model, the computation becomes intensive, and often an algorithm fails to converge. Moreover, in our analysis of smoking status and exposure to anti-tobacco advertisements, we have observed that when a model included multiple random effects, parameter estimates varied considerably from one statistical package to another even when using the same estimation method. This article presents a comprehensive review of the advantages and disadvantages of each estimation method. In addition, we compare the performances of the three methods across statistical packages via simulation, which involves two- and three-level logistic regression models with at least three correlated random effects. We apply our findings to a real dataset. Our results suggest that two packages—SAS GLIMMIX Laplace and SuperMix Gaussian quadrature—perform well in terms of accuracy, precision, convergence rates, and computing speed. We also discuss the strengths and weaknesses of the two packages in regard to sample sizes. PMID:24288415
Study on vacuum packaging reliability of micromachined quartz tuning fork gyroscopes
NASA Astrophysics Data System (ADS)
Fan, Maoyan; Zhang, Lifang
2017-09-01
Packaging technology of the micromachined quartz tuning fork gyroscopes by vacuum welding has been experimentally studied. The performance of quartz tuning fork is influenced by the encapsulation shell, encapsulation method and fixation of forks. Alloy solder thick film is widely used in the package to avoid the damage of the chip structure by the heat resistance and hot temperature, and this can improve the device performance and welding reliability. The results show that the bases and the lids plated with gold and nickel can significantly improve the airtightness and reliability of the vacuum package. Vacuum packaging is an effective method to reduce the vibration damping, improve the quality factor and further enhance the performance. The threshold can be improved nearly by 10 times.
MRBrainS Challenge: Online Evaluation Framework for Brain Image Segmentation in 3T MRI Scans.
Mendrik, Adriënne M; Vincken, Koen L; Kuijf, Hugo J; Breeuwer, Marcel; Bouvy, Willem H; de Bresser, Jeroen; Alansary, Amir; de Bruijne, Marleen; Carass, Aaron; El-Baz, Ayman; Jog, Amod; Katyal, Ranveer; Khan, Ali R; van der Lijn, Fedde; Mahmood, Qaiser; Mukherjee, Ryan; van Opbroek, Annegreet; Paneri, Sahil; Pereira, Sérgio; Persson, Mikael; Rajchl, Martin; Sarikaya, Duygu; Smedby, Örjan; Silva, Carlos A; Vrooman, Henri A; Vyas, Saurabh; Wang, Chunliang; Zhao, Liang; Biessels, Geert Jan; Viergever, Max A
2015-01-01
Many methods have been proposed for tissue segmentation in brain MRI scans. The multitude of methods proposed complicates the choice of one method above others. We have therefore established the MRBrainS online evaluation framework for evaluating (semi)automatic algorithms that segment gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) on 3T brain MRI scans of elderly subjects (65-80 y). Participants apply their algorithms to the provided data, after which their results are evaluated and ranked. Full manual segmentations of GM, WM, and CSF are available for all scans and used as the reference standard. Five datasets are provided for training and fifteen for testing. The evaluated methods are ranked based on their overall performance to segment GM, WM, and CSF and evaluated using three evaluation metrics (Dice, H95, and AVD) and the results are published on the MRBrainS13 website. We present the results of eleven segmentation algorithms that participated in the MRBrainS13 challenge workshop at MICCAI, where the framework was launched, and three commonly used freeware packages: FreeSurfer, FSL, and SPM. The MRBrainS evaluation framework provides an objective and direct comparison of all evaluated algorithms and can aid in selecting the best performing method for the segmentation goal at hand.
MRBrainS Challenge: Online Evaluation Framework for Brain Image Segmentation in 3T MRI Scans
Mendrik, Adriënne M.; Vincken, Koen L.; Kuijf, Hugo J.; Breeuwer, Marcel; Bouvy, Willem H.; de Bresser, Jeroen; Alansary, Amir; de Bruijne, Marleen; Carass, Aaron; El-Baz, Ayman; Jog, Amod; Katyal, Ranveer; Khan, Ali R.; van der Lijn, Fedde; Mahmood, Qaiser; Mukherjee, Ryan; van Opbroek, Annegreet; Paneri, Sahil; Pereira, Sérgio; Rajchl, Martin; Sarikaya, Duygu; Smedby, Örjan; Silva, Carlos A.; Vrooman, Henri A.; Vyas, Saurabh; Wang, Chunliang; Zhao, Liang; Biessels, Geert Jan; Viergever, Max A.
2015-01-01
Many methods have been proposed for tissue segmentation in brain MRI scans. The multitude of methods proposed complicates the choice of one method above others. We have therefore established the MRBrainS online evaluation framework for evaluating (semi)automatic algorithms that segment gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) on 3T brain MRI scans of elderly subjects (65–80 y). Participants apply their algorithms to the provided data, after which their results are evaluated and ranked. Full manual segmentations of GM, WM, and CSF are available for all scans and used as the reference standard. Five datasets are provided for training and fifteen for testing. The evaluated methods are ranked based on their overall performance to segment GM, WM, and CSF and evaluated using three evaluation metrics (Dice, H95, and AVD) and the results are published on the MRBrainS13 website. We present the results of eleven segmentation algorithms that participated in the MRBrainS13 challenge workshop at MICCAI, where the framework was launched, and three commonly used freeware packages: FreeSurfer, FSL, and SPM. The MRBrainS evaluation framework provides an objective and direct comparison of all evaluated algorithms and can aid in selecting the best performing method for the segmentation goal at hand. PMID:26759553
Encapsulants for protecting MEMS devices during post-packaging release etch
Peterson, Kenneth A.
2005-10-18
The present invention relates to methods to protect a MEMS or microsensor device through one or more release or activation steps in a "package first, release later" manufacturing scheme: This method of fabrication permits wirebonds, other interconnects, packaging materials, lines, bond pads, and other structures on the die to be protected from physical, chemical, or electrical damage during the release etch(es) or other packaging steps. Metallic structures (e.g., gold, aluminum, copper) on the device are also protected from galvanic attack because they are protected from contact with HF or HCL-bearing solutions.
NASA Technical Reports Server (NTRS)
Buntine, Wray
1993-01-01
This paper introduces the IND Tree Package to prospective users. IND does supervised learning using classification trees. This learning task is a basic tool used in the development of diagnosis, monitoring and expert systems. The IND Tree Package was developed as part of a NASA project to semi-automate the development of data analysis and modelling algorithms using artificial intelligence techniques. The IND Tree Package integrates features from CART and C4 with newer Bayesian and minimum encoding methods for growing classification trees and graphs. The IND Tree Package also provides an experimental control suite on top. The newer features give improved probability estimates often required in diagnostic and screening tasks. The package comes with a manual, Unix 'man' entries, and a guide to tree methods and research. The IND Tree Package is implemented in C under Unix and was beta-tested at university and commercial research laboratories in the United States.
Hassan, Muhammad Waqar; Gulraize; Ali, Usman; Ur Rehman, Fazal; Najeeb, Hafsa; Sohail, Maryam; Irsa, Bakhtawar; Muzaffar, Zubaria; Chaudhry, Muhammad Shafiq
2016-01-01
Three standard foodstuff plastic packaging namely polyethylene (PE), polypropylene (PP), and polyvinylchloride (PVC) were evaluated for management of lesser grain borer Rhyzopertha dominica (F.) (Coleoptera: Bostrichidae) and red flour beetle Tribolium castaneum (Herbst) (Coleoptera: Tenebrionidae). Resistance parameters in packaging were recorded as punctures, holes, penetrations, sealing defects, and invasions with two thicknesses and tested for two lengths of time. Damages like punctures, holes and penetrations by both insects were more in PE packaging however R. dominica made more penetrations in PP than in PE. For both insects sealing defects and invasions were predominant in PVC than in others. Thickness did not affect significantly damage types but significantly more holes and penetrations by R. dominica were in less thickness. Punctures and holes by R. dominica were more after less time period but other damages in packaging were more after more time period. However for T. castaneum all sorts of damages were seen more after more time period. Overall categorization between two insects showed R. dominica made more penetrations and T. castaneum made more invasions compared with their counterparts. Pictures were taken under camera fitted microscope to magnify punctures and holes in different packaging and thicknesses. Insect mortality due to phosphine was more in PP and PE packaging and least in PVC packaging and thickness effect was marginal. T. castaneum mortality was significantly more after 48 h than after 24 h. Damages extent in packaging and fumigation results showed PP to be the best of three packaging materials to manage these insects. PMID:27638958
USDA-ARS?s Scientific Manuscript database
Polystyrene is one of the most widely used plastics and is commonly produced in three forms: 1) Extruded polystyrene – disposable utensils, CD/DVD cases, yogurt containers, smoke alarm housing, etc.; 2) Expanded polystyrene foam – molded packaging materials and packaging "peanuts"; and 3) Extruded p...
ERIC Educational Resources Information Center
Mahoney, Joyce; And Others
1988-01-01
Evaluates 10 courseware packages covering topics for introductory physics. Discusses the price; sub-topics; program type; interaction; possible hardware; time; calculus required; graphics; and comments on each program. Recommends two packages in projectile and circular motion, and three packages in statics and rotational dynamics. (YP)
The Surgical Scrub. Learning Activity Package.
ERIC Educational Resources Information Center
Runge, Lillian
This learning activity package on the surgical scrub is one of a series of 12 titles developed for use in health occupations education programs. Materials in the package include objectives, a list of materials needed, a list of definitions, information sheets, reviews (self evaluations) of portions of the content, and answers to reviews. These…
15 CFR Appendix A to Part 946 - National Weather Service Modernization Criteria
Code of Federal Regulations, 2010 CFR
2010-01-01
... specifically in Addendum I, Appendix D of the ASOS Site Component Commissioning Evaluation Package (the ASOS Package). Criteria: a. ASOS Acceptance Test: The site component acceptance test, which includes objective..., has been successfully completed in accordance with item 1a, p. D-2 of Appendix D of the ASOS Package...
15 CFR Appendix A to Part 946 - National Weather Service Modernization Criteria
Code of Federal Regulations, 2013 CFR
2013-01-01
... specifically in Addendum I, Appendix D of the ASOS Site Component Commissioning Evaluation Package (the ASOS Package). Criteria: a. ASOS Acceptance Test: The site component acceptance test, which includes objective..., has been successfully completed in accordance with item 1a, p. D-2 of Appendix D of the ASOS Package...
15 CFR Appendix A to Part 946 - National Weather Service Modernization Criteria
Code of Federal Regulations, 2012 CFR
2012-01-01
... specifically in Addendum I, Appendix D of the ASOS Site Component Commissioning Evaluation Package (the ASOS Package). Criteria: a. ASOS Acceptance Test: The site component acceptance test, which includes objective..., has been successfully completed in accordance with item 1a, p. D-2 of Appendix D of the ASOS Package...
15 CFR Appendix A to Part 946 - National Weather Service Modernization Criteria
Code of Federal Regulations, 2011 CFR
2011-01-01
... specifically in Addendum I, Appendix D of the ASOS Site Component Commissioning Evaluation Package (the ASOS Package). Criteria: a. ASOS Acceptance Test: The site component acceptance test, which includes objective..., has been successfully completed in accordance with item 1a, p. D-2 of Appendix D of the ASOS Package...
Need for certification of household water treatment products: examples from Haiti
Murray, Anna; Pierre-Louis, Jocelyne; Joseph, Flaurine; Sylvain, Ginelove; Patrick, Molly; Lantagne, Daniele
2015-01-01
OBJECTIVE To evaluate four household water treatment (HWT) products currently seeking approval for distribution in Haiti, through the application of a recently-developed national HWT product certification process. METHODS Four chemical treatment products were evaluated against the certification process validation stage by verifying international product certifications confirming treatment efficacy and reviewing laboratory efficacy data against WHO HWT microbiological performance targets; and against the approval stage by confirming product composition, evaluating treated water chemical content against national and international drinking water quality guidelines and reviewing packaging for dosing ability and usage directions in Creole. RESULTS None of the four evaluated products fulfilled validation or approval stage requirements. None was certified by an international agency as efficacious for drinking water treatment, and none had data demonstrating its ability to meet WHO HWT performance targets. All product sample compositions differed from labelled composition by >20%, and no packaging included complete usage directions in Creole. CONCLUSIONS Product manufacturers provided information that was inapplicable, did not demonstrate product efficacy, and was insufficient to ensure safe product use. Capacity building is needed with country regulatory agencies to objectively evaluate HWT products. Products should be internationally assessed against WHO performance targets and also locally approved, considering language, culture and usability, to ensure effective HWT. PMID:25441711
Spectroscopic investigation of a dielectric barrier discharge in modified atmosphere packaging
NASA Astrophysics Data System (ADS)
Milosavljević, Vladimir; Cullen, Patrick J.
2017-11-01
Diagnostics of a dielectric barrier discharge (DBD), in a sealed package (with and without meat) filled with gas mixtures of oxygen and carbon-dioxide (O2-CO2), is reported. The generation and evaluation of the plasma chemistry induced within the confines of the sealed package is studied. The plasma discharges were analyzed by optical emission spectroscopy (OES) and optical absorption spectroscopy (OAS) over a range of plasma process parameters. The study includes a detailed experimental investigation of the spatial and temporal spectroscopic data and links them with plasma kinetics. The results from the spectral radiation from package provide information about the electron energy distribution function. The experimental data indicates that the humidity level in the package with and without meat is unchanged, and that the gas temperature was not significantly modified. Oxygen and nitrogen radicals (trapped gas atmosphere and modified atmosphere) are increased in the package containing meat; at the same time there is no evidence of the presence of carbon monoxide molecules. The role of the nitrogen molecule in the quenching of O2 and CO2 molecules is also evaluated.
2006-06-30
KENNEDY SPACE CENTER, FLA. - In the Space Station Processing Facility at NASA's Kennedy Space Center, John Hoog secures a bag filled with prepared meals for the crew of mission STS-121 before packing into containers for the flight. At left is Dennis Huefner, with United Space Alliance (USA) ground operations. Hoog is a USA-FCE/EVA representative from Johnson Space Center. Astronauts select their own menus from a large array of food items. Astronauts are supplied with three balanced meals, plus snacks. Foods flown on space missions are researched and developed at the Space Food Systems Laboratory at the Johnson Space Center (JSC) in Houston, which is staffed by food scientists, dietitians and engineers. Foods are analyzed through nutritional analysis, sensory evaluation, storage studies, packaging evaluations and many other methods. Each astronaut’s food is stored aboard the space shuttle and is identified by a colored dot affixed to each package. Launch of Space Shuttle Discovery on mission STS-121 is scheduled for July 1. Photo credit: NASA/Jack Pfaller
2006-06-30
KENNEDY SPACE CENTER, FLA. - In the Space Station Processing Facility at NASA's Kennedy Space Center, flight crew systems technician Troy Mann and flight crew systems manager Jim Blake secure the storage boxes holding the food containers that will be stowed on Space Shuttle Discovery for the flight of mission STS-121. The containers hold meals prepared for the mission crew. Astronauts select their own menus from a large array of food items. Astronauts are supplied with three balanced meals, plus snacks. Foods flown on space missions are researched and developed at the Space Food Systems Laboratory at the Johnson Space Center (JSC) in Houston, which is staffed by food scientists, dietitians and engineers. Foods are analyzed through nutritional analysis, sensory evaluation, storage studies, packaging evaluations and many other methods. Each astronaut’s food is stored aboard the space shuttle and is identified by a colored dot affixed to each package. Launch of Space Shuttle Discovery on mission STS-121 is scheduled for July 1. Photo credit: NASA/Jack Pfaller
2006-06-30
KENNEDY SPACE CENTER, FLA. - In the Space Station Processing Facility at NASA's Kennedy Space Center, flight crew systems technician Troy Mann and flight crew systems manager Jim Blake store the food containers that will be stowed on Space Shuttle Discovery for the flight of mission STS-121. The containers hold meals prepared for the mission crew. Mann and Blake are with United Space Alliance ground operations. Astronauts select their own menus from a large array of food items. Astronauts are supplied with three balanced meals, plus snacks. Foods flown on space missions are researched and developed at the Space Food Systems Laboratory at the Johnson Space Center (JSC) in Houston, which is staffed by food scientists, dietitians and engineers. Foods are analyzed through nutritional analysis, sensory evaluation, storage studies, packaging evaluations and many other methods. Each astronaut’s food is stored aboard the space shuttle and is identified by a colored dot affixed to each package. Launch of Space Shuttle Discovery on mission STS-121 is scheduled for July 1. Photo credit: NASA/Jack Pfaller
2006-06-30
KENNEDY SPACE CENTER, FLA. - In the Space Station Processing Facility at NASA's Kennedy Space Center, Jim Blake, Dennis Huefner and Troy Mann wrap food containers that will be stowed on Space Shuttle Discovery for the flight of mission STS-121. The containers hold meals prepared for the mission crew. The men are with United Space Alliance ground operations. Astronauts select their own menus from a large array of food items. Astronauts are supplied with three balanced meals, plus snacks. Foods flown on space missions are researched and developed at the Space Food Systems Laboratory at the Johnson Space Center (JSC) in Houston, which is staffed by food scientists, dietitians and engineers. Foods are analyzed through nutritional analysis, sensory evaluation, storage studies, packaging evaluations and many other methods. Each astronaut’s food is stored aboard the space shuttle and is identified by a colored dot affixed to each package. Launch of Space Shuttle Discovery on mission STS-121 is scheduled for July 1. Photo credit: NASA/Jack Pfaller
OWL: A scalable Monte Carlo simulation suite for finite-temperature study of materials
NASA Astrophysics Data System (ADS)
Li, Ying Wai; Yuk, Simuck F.; Cooper, Valentino R.; Eisenbach, Markus; Odbadrakh, Khorgolkhuu
The OWL suite is a simulation package for performing large-scale Monte Carlo simulations. Its object-oriented, modular design enables it to interface with various external packages for energy evaluations. It is therefore applicable to study the finite-temperature properties for a wide range of systems: from simple classical spin models to materials where the energy is evaluated by ab initio methods. This scheme not only allows for the study of thermodynamic properties based on first-principles statistical mechanics, it also provides a means for massive, multi-level parallelism to fully exploit the capacity of modern heterogeneous computer architectures. We will demonstrate how improved strong and weak scaling is achieved by employing novel, parallel and scalable Monte Carlo algorithms, as well as the applications of OWL to a few selected frontier materials research problems. This research was supported by the Office of Science of the Department of Energy under contract DE-AC05-00OR22725.
soilphysics: An R package to determine soil preconsolidation pressure
NASA Astrophysics Data System (ADS)
da Silva, Anderson Rodrigo; de Lima, Renato Paiva
2015-11-01
Preconsolidation pressure is a parameter obtained from the soil compression curve and has been used as an indicator of load-bearing capacity of soil, as well as to characterize the impacts suffered by the use of machines. Despite its importance in soil physics, there is a few software or computational routines to support its determination. In this paper we present a computational package in R language, the package soilphysics, which contains implementations of the main methods for determining preconsolidation pressure, such as the method of Casagrande, Pacheco Silva, regression methods and the method of the virgin compression line intercept. There is still a consensus that Casagrande is the standard method, although the method of Pacheco Silva has shown similar values. The method of the virgin compression line intercept can be used when trying to be more conservative on the value (smaller) of preconsolidation pressure. Furthermore, Casagrande could be replaced by a regression method when the compression curve is obtained from saturated soils. The theory behind each method is presented and the algorithms are thoroughly described. We also give some support on how to use the R functions. Examples are used to illustrate the capabilities of the package, and the results are briefly discussed. The latter were validated using a recently published VBA. With soilphysics, the user has all the graphical and statistical power of R to determine preconsolidation pressure using different methods. The package is distribution free (under the GPL-2|3) and is currently available from the Comprehensive R Archive Network.
1982-05-01
SELECTION AND EVALUATION . . . . . . . . . . . . . . 2 2.2 MICROELECTRONIC PACKAGES AND THEIR QUALITY . . . * . . . . . . . . 5 2.3 EQUIPMENT...liquid penetrant testing for various microelectronic package hermeticity. I t I MATERIALS AND EQUIPMENT 2.1 DYE PENETRANT SELECTION AND EVALUATION...a commercial visible dye penetrant and a commercial fluorescent dye penetrant were selected as being suitable for the testing of microelectronic
ERIC Educational Resources Information Center
Schneiderman, Deborah; Freihoefer, Kara
2012-01-01
Purpose: The purpose of this paper is to examine the integration of Okala curriculum into Interior Design coursework. Okala, as a teaching package, is utilized extensively in industrial design education. However, this study examines the expansion and insertion of Okala modules in an existing interior design curriculum. The Okala modules included…
GneimoSim: A Modular Internal Coordinates Molecular Dynamics Simulation Package
Larsen, Adrien B.; Wagner, Jeffrey R.; Kandel, Saugat; Salomon-Ferrer, Romelia; Vaidehi, Nagarajan; Jain, Abhinandan
2014-01-01
The Generalized Newton Euler Inverse Mass Operator (GNEIMO) method is an advanced method for internal coordinates molecular dynamics (ICMD). GNEIMO includes several theoretical and algorithmic advancements that address longstanding challenges with ICMD simulations. In this paper we describe the GneimoSim ICMD software package that implements the GNEIMO method. We believe that GneimoSim is the first software package to include advanced features such as the equipartition principle derived for internal coordinates, and a method for including the Fixman potential to eliminate systematic statistical biases introduced by the use of hard constraints. Moreover, by design, GneimoSim is extensible and can be easily interfaced with third party force field packages for ICMD simulations. Currently, GneimoSim includes interfaces to LAMMPS, OpenMM, Rosetta force field calculation packages. The availability of a comprehensive Python interface to the underlying C++ classes and their methods provides a powerful and versatile mechanism for users to develop simulation scripts to configure the simulation and control the simulation flow. GneimoSim has been used extensively for studying the dynamics of protein structures, refinement of protein homology models, and for simulating large scale protein conformational changes with enhanced sampling methods. GneimoSim is not limited to proteins and can also be used for the simulation of polymeric materials. PMID:25263538
GneimoSim: a modular internal coordinates molecular dynamics simulation package.
Larsen, Adrien B; Wagner, Jeffrey R; Kandel, Saugat; Salomon-Ferrer, Romelia; Vaidehi, Nagarajan; Jain, Abhinandan
2014-12-05
The generalized Newton-Euler inverse mass operator (GNEIMO) method is an advanced method for internal coordinates molecular dynamics (ICMD). GNEIMO includes several theoretical and algorithmic advancements that address longstanding challenges with ICMD simulations. In this article, we describe the GneimoSim ICMD software package that implements the GNEIMO method. We believe that GneimoSim is the first software package to include advanced features such as the equipartition principle derived for internal coordinates, and a method for including the Fixman potential to eliminate systematic statistical biases introduced by the use of hard constraints. Moreover, by design, GneimoSim is extensible and can be easily interfaced with third party force field packages for ICMD simulations. Currently, GneimoSim includes interfaces to LAMMPS, OpenMM, and Rosetta force field calculation packages. The availability of a comprehensive Python interface to the underlying C++ classes and their methods provides a powerful and versatile mechanism for users to develop simulation scripts to configure the simulation and control the simulation flow. GneimoSim has been used extensively for studying the dynamics of protein structures, refinement of protein homology models, and for simulating large scale protein conformational changes with enhanced sampling methods. GneimoSim is not limited to proteins and can also be used for the simulation of polymeric materials. © 2014 Wiley Periodicals, Inc.
A Review of Patents for the Smart Packaging of Meat and Muscle-based Food Products.
Holman, Benjamin; Kerry, Joseph P; Hopkins, David L
2017-10-31
Meat packaging once acted primarily as an inert barrier to protect its contents against contamination and this function has shifted. Packaging now includes complementary functions that improve product quality, longevity and customer/retail appeal. The devices and methods applied to achieve these functions may be categorised as smart packaging, which includes intelligent packaging, devised to monitor and communicate packaged content status, and active packaging, to provide passive adjustment of in-pack conditions from its interactions with the packaged meat. Smart packaging examples already available from recent patents include antimicrobial and antioxidant packaging coatings and inserts; sensors or indicators that identify spoilage and freshness; functional engineering customisations; improvements to packaging integrity; leak or tamper detectors; and, environmentally sustainable options. Together, these inventions respond to industry and customer demands for meat packaging and are therefore the focus of this review, in which we discuss their applications and limitations in meat packaging. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Roos, Malgorzata; Stawarczyk, Bogna
2012-07-01
This study evaluated and compared Weibull parameters of resin bond strength values using six different general-purpose statistical software packages for two-parameter Weibull distribution. Two-hundred human teeth were randomly divided into 4 groups (n=50), prepared and bonded on dentin according to the manufacturers' instructions using the following resin cements: (i) Variolink (VAN, conventional resin cement), (ii) Panavia21 (PAN, conventional resin cement), (iii) RelyX Unicem (RXU, self-adhesive resin cement) and (iv) G-Cem (GCM, self-adhesive resin cement). Subsequently, all specimens were stored in water for 24h at 37°C. Shear bond strength was measured and the data were analyzed using Anderson-Darling goodness-of-fit (MINITAB 16) and two-parameter Weibull statistics with the following statistical software packages: Excel 2011, SPSS 19, MINITAB 16, R 2.12.1, SAS 9.1.3. and STATA 11.2 (p≤0.05). Additionally, the three-parameter Weibull was fitted using MNITAB 16. Two-parameter Weibull calculated with MINITAB and STATA can be compared using an omnibus test and using 95% CI. In SAS only 95% CI were directly obtained from the output. R provided no estimates of 95% CI. In both SAS and R the global comparison of the characteristic bond strength among groups is provided by means of the Weibull regression. EXCEL and SPSS provided no default information about 95% CI and no significance test for the comparison of Weibull parameters among the groups. In summary, conventional resin cement VAN showed the highest Weibull modulus and characteristic bond strength. There are discrepancies in the Weibull statistics depending on the software package and the estimation method. The information content in the default output provided by the software packages differs to very high extent. Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Tang, Henry H.; Orndoff, Evelyne S.; Thomas, Gretchen A.
2009-01-01
This paper discusses the effort in evaluating and selecting a light weight impact protection material for the Constellation Space Suit Element (CSSE) Portable Life Support Subsystem (PLSS) conceptual packaging study. A light weight material capable of holding and protecting the components inside the PLSS is required to demonstrate the viability of the flexible PLSS packaging concept. The material needs to distribute, dissipate, and absorb the impact energy of the PLSS falling on the lunar surface. It must also be very robust and function in the extreme lunar thermal vacuum environment for up to one hundred Extravehicular Activity (EVA) missions. This paper documents the performance requirements for selecting a foam protection material, and the methodologies for evaluating commercial off-the-shelf (COTS) foam protection materials. It also presents the materials properties test results and impact drop test results of the various foam materials evaluated in the study. The findings from this study suggest that a foam based flexible protection system is a viable solution for PLSS packaging. However, additional works are needed to optimize COTS foam properties or to develop a composite foam system that will meet all the performance requirements for the CSSE PLSS flexible packaging.
Brown, Alison L; Brooks, J Chance; Karunasena, Enusha; Echeverry, Alejandro; Laury, Angela; Brashears, Mindy M
2011-08-01
Implementation of modified atmospheric packaging (MAP) into retail produce is a less commonly practiced method due to differences among commodities and the potential growth of anaerobes. Pathogens including Escherichia coli O157:H7 have been responsible for spinach outbreaks across the United States. In this study, hurdles, including those currently used with produce safety, such as MAP and chlorine, were combined with lactic acid bacteria (LAB) to inhibit pathogens. Spinach was coinoculated with E. coli O157:H7 and Clostridium sporogenes, a surrogate for C. botulinum, and treated with water or a hurdle that included water, chlorine, and LAB. Spinach from treatments were packaged in air (traditional), oxygen (80% O₂, 20% CO₂), or nitrogen (80% N₂, 20% CO₂) and stored in a retail display case for 9 d at 4 to 7 °C. The hurdle inhibited E. coli O157:H7 and C. sporogenes compared to controls with reductions of 1.43 and 1.10 log (P < 0.05), respectively. The nitrogen atmosphere was outperformed by air and oxygen in the reduction of E. coli O157:H7 (P < 0.05) with a decrease of 0.26 and 0.15 logs. There were no significant differences among the 3 atmospheres on C. sporogenes survival. Relative to these hurdles, we also chose to evaluate the potential benefits of LAB in pathogen control. The survival of LAB in interventions demonstrates implementation of LAB into produce could control pathogens, without damaging produce or altering organoleptic properties. The goal of our work was to identify methods that could reduce food-borne pathogens in packaged spinach products. Using current industry techniques in combination with unique methods, such as the use of beneficial bacteria, our research identified whether harmful microorganisms could be eliminated. Our data demonstrate that specific packaging conditions with beneficial bacteria can help eliminate or reduce the survival of E. coli O157:H7 and C. sporogenes (a model for C. botulinum) in produce. Journal of Food Science © 2011 Institute of Food Technologists® No claim to original US government works.
DOE Office of Scientific and Technical Information (OSTI.GOV)
N /A
Bonneville is responsible for maintaining a network of 24,000 kilometers (km) or 15,000 miles (mi.) of electric transmission lines and 350 substations in a region of diverse vegetation. This vegetation can interfere with electric power flow, pose safety problems for us and the public, and interfere with our ability to maintain these facilities. We need to (1) keep vegetation away from the electric facilities; (2) increase the program efficiency and consistency; (3) review herbicide use (under increased public scrutiny); and (4) maximize the range of tools we can use while minimizing environmental impact (Integrated Vegetation Management). This DEIS establishes Planningmore » Steps for managing vegetation for specific projects (to be tiered to this EIS). In addition to No Action (current practice), alternatives are presented for Rights-of-way, Electric Yards, and Non-electric Facilities (landscaping, work yards). Four vegetation control methods are analyzed: manual, mechanical, herbicide, and biological. Also evaluated are 24 herbicide active ingredients and 4 herbicide application techniques (spot, localized, broadcast, and aerial). For rights-of-way, they consider three sets of alternatives: alternative management approaches (time-driven or establishing low-growing plant communities); alternative method packages; and, if herbicides are in a methods package, alternative vegetation selections (noxious weeds, deciduous, or any vegetation). For electric yards, one herbicide-use alternative is considered. For non-electric facilities, two method package alternatives are considered. For rights-of-way, the environmentally preferred alternative(s) would use manual, mechanical, and biological control methods, as well as spot and localized herbicide applications for noxious and deciduous plant species; the BPA-preferred alternative(s) would add broadcast and aerial herbicide applications, and would use herbicides on any vegetation. Both would factor a management approach that fosters low-growing plant communities.« less
Design Evolution Study - Aging Options
DOE Office of Scientific and Technical Information (OSTI.GOV)
P. McDaniel
The purpose of this study is to identify options and issues for aging commercial spent nuclear fuel received for disposal at the Yucca Mountain Mined Geologic Repository. Some early shipments of commercial spent nuclear fuel to the repository may be received with high-heat-output (younger) fuel assemblies that will need to be managed to meet thermal goals for emplacement. The capability to age as much as 40,000 metric tons of heavy metal of commercial spent nuclear he1 would provide more flexibility in the design to manage this younger fuel and to decouple waste receipt and waste emplacement. The following potential agingmore » location options are evaluated: (1) Surface aging at four locations near the North Portal; (2) Subsurface aging in the permanent emplacement drifts; and (3) Subsurface aging in a new subsurface area. The following aging container options are evaluated: (1) Complete Waste Package; (2) Stainless Steel inner liner of the waste package; (3) Dual Purpose Canisters; (4) Multi-Purpose Canisters; and (5) New disposable canister for uncanistered commercial spent nuclear fuel. Each option is compared to a ''Base Case,'' which is the expected normal waste packaging process without aging. A Value Engineering approach is used to score each option against nine technical criteria and rank the options. Open issues with each of the options and suggested future actions are also presented. Costs for aging containers and aging locations are evaluated separately. Capital costs are developed for direct costs and distributable field costs. To the extent practical, unit costs are presented. Indirect costs, operating costs, and total system life cycle costs will be evaluated outside of this study. Three recommendations for aging commercial spent nuclear fuel--subsurface, surface, and combined surface and subsurface are presented for further review in the overall design re-evaluation effort. Options that were evaluated but not recommended are: subsurface aging in a new subsurface area (high cost); surface aging in the complete waste package (risk to the waste package and impact on the Waste Handling Facility); and aging in the stainless steel liner (impact on the waste package design and new high risk operations added to the waste packaging process). The selection of a design basis for aging will be made in conjunction with the other design re-evaluation studies.« less
Investigation into the development of computer aided design software for space based sensors
NASA Technical Reports Server (NTRS)
Pender, C. W.; Clark, W. L.
1987-01-01
The described effort is phase one of the development of a Computer Aided Design (CAD) software to be used to perform radiometric sensor design. The software package will be referred to as SCAD and is directed toward the preliminary phase of the design of space based sensor system. The approach being followed is to develop a modern, graphic intensive, user friendly software package using existing software as building blocks. The emphasis will be directed toward the development of a shell containing menus, smart defaults, and interfaces, which can accommodate a wide variety of existing application software packages. The shell will offer expected utilities such as graphics, tailored menus, and a variety of drivers for I/O devices. Following the development of the shell, the development of SCAD is planned as chiefly selection and integration of appropriate building blocks. The phase one development activities have included: the selection of hardware which will be used with SCAD; the determination of the scope of SCAD; the preliminary evaluation of a number of software packages for applicability to SCAD; determination of a method for achieving required capabilities where voids exist; and then establishing a strategy for binding the software modules into an easy to use tool kit.
Martinis, Estefanía M; Olsina, Roberto A; Altamirano, Jorgelina C; Wuilloud, Rodolfo G
2009-05-15
A novel on-line preconcentration method based on liquid-liquid (L-L) extraction with room temperature ionic liquids (RTILs) coupled to flame atomic absorption spectrometry (FAAS) was developed for cadmium determination in plastic food packaging materials. The methodology is based on the complexation of Cd with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) reagent after sample digestion followed by extraction of the complex with the RTIL 1-butyl-3-methylimidazolium hexafluorophosphate ([C(4)mim][PF(6)]). The mixture was loaded into a flow injection analysis (FIA) manifold and the RTIL rich-phase was retained in a microcolumn filled with silica gel. The RTIL rich-phase was then eluted directly into FAAS. A enhancement factor of 35 was achieved with 20 mL of sample. The limit of detection (LOD), obtained as IUPAC recommendation, was 6 ng g(-1) and the relative standard deviation (R.S.D.) for 10 replicates at 10 microg L(-1) Cd concentration level was 3.9%, calculated at the peak heights. The calibration graph was linear and a correlation coefficient of 0.9998 was achieved. The accuracy of the method was evaluated by both a recovery study and comparison of results with direct determination by electrothermal atomic absorption spectrometry (ETAAS). The method was successfully applied for Cd determination in plastic food packaging materials and Cd concentrations found were in the range of 0.04-10.4 microg g(-1).
TYPE A FISSILE PACKAGING FOR AIR TRANSPORT PROJECT OVERVIEW
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eberl, K.; Blanton, P.
2013-10-11
This paper presents the project status of the Model 9980, a new Type A fissile packaging for use in air transport. The Savannah River National Laboratory (SRNL) developed this new packaging to be a light weight (<150-lb), drum-style package and prepared a Safety Analysis for Packaging (SARP) for submission to the DOE/EM. The package design incorporates unique features and engineered materials specifically designed to minimize packaging weight and to be in compliance with 10CFR71 requirements. Prototypes were fabricated and tested to evaluate the design when subjected to Normal Conditions of Transport (NCT) and Hypothetical Accident Conditions (HAC). An overview ofmore » the design details, results of the regulatory testing, and lessons learned from the prototype fabrication for the 9980 will be presented.« less
Jairath, Gauri; Chatli, Manish K; Sahoo, Jhari; Biswas, Ashim K
2015-06-01
The storage stability of enrobed goat meat bites (EGMB) incorporated with 3 % crude aloe vera (AV) gel was evaluated under aerobic (T-1; unenrobed control product, T-2; enrobed AV treated product) and modified atmospheric packaging (MAP, 50:50, CO2 and N2) (T-3; unenrobed control product, T-4; enrobed AV treated product) at 4 ± 1 °C for 42 days on the basis of physico-chemical, microbiological and sensory attributes. The pH value was higher, whereas water activity (aW) was lower in enrobed and MAP product. Thiobarbituric acid reacting substances (TBARS) and free fatty acid (FFA) values were significantly (P < 0.05) lower in MAP packaged (T-3) and AV treated products (T-2 and T-4) products than aerobic packaged (T-1), however it followed an increasing trend in all the products throughout storage. Instrumental colour and textural profile attributes were better maintained in MAP products than others. The sensory panellists graded T-4 'good to very good' even on Day 42, whereas T-1 was acceptable only up to 28 days. Standard Plate Count (SPC) was significantly (P < 0.05) lower in MAP products than aerobic packaged products. Results concluded that EGMB treated with AV gel can be successfully stored more than 42 days under MAP conditions without affecting its physico-chemical, textural, microbiological and sensory attributes.
Do isolated packaging variables influence consumers' attention and preferences?
García-Madariaga, Jesús; Blasco López, Maria-Francisca; Burgos, Ingrit Moya; Virto, Nuria Recuero
2018-04-25
Developments in neuroscience have provided the opportunity to know unconscious consumer reactions and acknowledge direct measures of cognitive constructs like attention. Given the ever-increasing concern over packaging's contribution to creating a positive first impression, the current research seeks to examine consumers' attention and declarative preferences regarding the three main different packaging attributes as isolated variables: images, texts and colours. The experiment exposed participants (N = 40) to 63 stimuli, which were based on modifications of the three main packaging attributes of three products of three different food categories. This study used electroencephalogram (EEG) and eye-tracking (ET) to measure attention, and a declarative test was employed to examine preference. First, the results presented herein show that the presence of visual elements, either images or texts on packages, increased the participants' level of attention. Second, the results reveal that colour modifications do not have a significant effect on participants' neurophysiological attention levels. Third, the results demonstrated that the neurophysiological effects among the participants do not necessarily coincide with their subjective evaluations of preference. Hence, this study increases awareness of the relevance of combining traditional market research tools that rely on explicit consumer responses with neuroscientific techniques. These findings indicate, first of all, that more research is needed to ascertain the extent to which consumers' neurophysiological outcomes correspond to their declarative preferences and second, that neurophysiological methods should be given more attention in research. Copyright © 2018 Elsevier Inc. All rights reserved.
Attic or Roof? An Evaluation of Two Advanced Weatherization Packages
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neuhauser, Ken
2012-06-01
This project examines implementation of advanced retrofit measures in the context of a large-scale weatherization program and the archetypal Chicago brick bungalow. One strategy applies best practice air sealing methods and a standard insulation method to the attic floor. The other strategy creates an unvented roof assembly using materials and methods typically available to weatherization contractors. Through implementations of the retrofit strategies in a total of eight (8) test homes, the research found that the two different strategies achieve similar reductions in air leakage measurement (55%) and predicted energy performance (18%) relative to the pre-retrofit conditions.
A method for exponential propagation of large systems of stiff nonlinear differential equations
NASA Technical Reports Server (NTRS)
Friesner, Richard A.; Tuckerman, Laurette S.; Dornblaser, Bright C.; Russo, Thomas V.
1989-01-01
A new time integrator for large, stiff systems of linear and nonlinear coupled differential equations is described. For linear systems, the method consists of forming a small (5-15-term) Krylov space using the Jacobian of the system and carrying out exact exponential propagation within this space. Nonlinear corrections are incorporated via a convolution integral formalism; the integral is evaluated via approximate Krylov methods as well. Gains in efficiency ranging from factors of 2 to 30 are demonstrated for several test problems as compared to a forward Euler scheme and to the integration package LSODE.
Packaging system with cleaning channel and method of making the same
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fang, Lu
A packaging structure and method for surface mount integrated circuits reduces electrochemical migration (ECM) problems by including one or more cleaning channels to effectively and efficiently remove flux residue that may otherwise remain lodged in gaps between the surface mount package and the printed circuit board. A cleaning channel may be formed along a bottom surface of the surface mount package (i.e., the surface facing the printed circuit board), or along a portion of a top surface of the printed circuit board. In either case, the inclusion of a cleaning channel enlarges the gap between the bottom surface of themore » surface mount package and the printed circuit board and creates a path for contaminants to be flushed out during a cleaning process.« less
A parent advice package for family shopping trips: development and evaluation1
Clark, Hewitt B.; Greene, Brandon F.; Macrae, John W.; McNees, M. Patrick; Davis, Jerry L.; Risley, Todd R.
1977-01-01
This article reports on the primary steps in the development of parent advice for popular dissemination: (a) developing advice for one specific problem situation, family shopping trips; (b) testing the advice program for benefit to children and convenience to adults; and (c) packaging the advice so it can be used successfully by interested parents. Systematic observation of 12 families using the written advice package on shopping trips revealed its effectiveness in reducing child disruptions and increasing positive interactions between parents and children. These findings, along with interview information from families, showed that the package is usable, effective, and popular with both parents and children, and thus is ready for dissemination to a wide audience of parents—a step that in itself should involve research and evaluation. PMID:16795570
Youssef, Ahmed M; Kamel, S; El-Samahy, M A
2013-10-15
With the increasing sustainability trend with packaging materials, paper and polymer nanocomposites represent a novel class of packaging materials. This study evaluates the potential achievement of alternative sustainable materials as antibacterial packaging application. Paper sheet from rice straw coated with 5 or 10% polystyrene (PS) nanocomposites using titanium dioxide nanoparticles (TiO2-NPs) doped or undoped with sliver nanoparticles (Ag-NPs) were prepared. The morphology of the uncoated and coated paper sheets was studied by SEM. The treated paper sheets were analyzed for their elemental composition using EDAX. The Barrier, air permeability, cob test, as well as mechanical properties and tensile strength were also evaluated. The inhibitory effect of modified paper sheets against Pseudomonas, Staphylococcus aureus, Candida, and Staphylococcus were investigated. Copyright © 2013 Elsevier Ltd. All rights reserved.
Martínez-Moral, María Pilar; Tena, María Teresa
2012-11-15
The development and characterisation of a method based on reverse-phase ultra-performance liquid chromatography (UPLC) coupled to a quadrupole-time of flight mass spectrometer (Q-TOF-MS) with negative electrospray ionisation (ESI) to determine perfluorinated compounds (PFCs) in packaging is presented in this paper. Analytes were quantitatively recovered from packaging with methanol in only one PLE cycle of 6 min at 100 °C. The UPLC allowed the successful separation of the studied PFCs in less than 4 min. The whole method presented good precision, with RSDs below 8%, LODs from 0.6 to 16 ng g(-1); and excellent recovery values, around 100% in all cases, were achieved. The PLE-UPLC-MS method was applied to the analysis of popcorn packaging for microwave cooking. Besides the most commonly studied PFCs: PFOA and PFOS, the presence of other perfluorocarboxylic acids (PFCAs) in popcorn packaging is evidenced in this work. Copyright © 2012 Elsevier B.V. All rights reserved.
An overview of NSPCG: A nonsymmetric preconditioned conjugate gradient package
NASA Astrophysics Data System (ADS)
Oppe, Thomas C.; Joubert, Wayne D.; Kincaid, David R.
1989-05-01
The most recent research-oriented software package developed as part of the ITPACK Project is called "NSPCG" since it contains many nonsymmetric preconditioned conjugate gradient procedures. It is designed to solve large sparse systems of linear algebraic equations by a variety of different iterative methods. One of the main purposes for the development of the package is to provide a common modular structure for research on iterative methods for nonsymmetric matrices. Another purpose for the development of the package is to investigate the suitability of several iterative methods for vector computers. Since the vectorizability of an iterative method depends greatly on the matrix structure, NSPCG allows great flexibility in the operator representation. The coefficient matrix can be passed in one of several different matrix data storage schemes. These sparse data formats allow matrices with a wide range of structures from highly structured ones such as those with all nonzeros along a relatively small number of diagonals to completely unstructured sparse matrices. Alternatively, the package allows the user to call the accelerators directly with user-supplied routines for performing certain matrix operations. In this case, one can use the data format from an application program and not be required to copy the matrix into one of the package formats. This is particularly advantageous when memory space is limited. Some of the basic preconditioners that are available are point methods such as Jacobi, Incomplete LU Decomposition and Symmetric Successive Overrelaxation as well as block and multicolor preconditioners. The user can select from a large collection of accelerators such as Conjugate Gradient (CG), Chebyshev (SI, for semi-iterative), Generalized Minimal Residual (GMRES), Biconjugate Gradient Squared (BCGS) and many others. The package is modular so that almost any accelerator can be used with almost any preconditioner.
Design and Evaluation of an Integrated Online Motion Control Training Package
ERIC Educational Resources Information Center
Buiu, C.
2009-01-01
The aim of this paper is to present an integrated Internet-based package for teaching the fundamentals of motion control by using a wide range of resources: theory, videos, simulators, games, quizzes, and a remote lab. The package is aimed at automation technicians, pupils at vocational schools and students taking an introductory course in…
USDA-ARS?s Scientific Manuscript database
The primary material used by the packaging industry is extruded polystyrene foam, which is commonly marketed as Styrofoam™. In its original formulation, Styrofoam™ is resistant to photolysis and effectively does not decompose. The light weight of Styrofoam™ packaging materials reduces the likelihood...
PresenceAbsence: An R package for presence absence analysis
Elizabeth A. Freeman; Gretchen Moisen
2008-01-01
The PresenceAbsence package for R provides a set of functions useful when evaluating the results of presence-absence analysis, for example, models of species distribution or the analysis of diagnostic tests. The package provides a toolkit for selecting the optimal threshold for translating a probability surface into presence-absence maps specifically tailored to their...
Food System Trade Study for a Near-Term Mars Mission
NASA Technical Reports Server (NTRS)
Levri, Julie; Luna, Bernadette (Technical Monitor)
2000-01-01
This paper evaluates several food system options for a near-term Mars mission, based on plans for the 120-day BIO-Plex test. Food systems considered in the study are based on the International Space Station (ISS) Assembly Phase and Assembly Complete food systems. The four systems considered are: 1) ISS assembly phase food system (US portion) with individual packaging without salad production; 2) ISS assembly phase food system (US portion) with individual packaging, with salad production; 3) ISS assembly phase food system (US portion) with bulk packaging, with salad production; 4) ISS assembly complete food system (US portion) with bulk packaging with salad and refrigeration/freezing. The food system options are assessed using equivalent system mass (ESM), which evaluates each option based upon the mass, volume, power, cooling and crewtime requirements that are associated with each food system option. However, since ESM is unable to elucidate the differences in psychological benefits between the food systems, a qualitative evaluation of each option is also presented.
Evaluation of tools for highly variable gene discovery from single-cell RNA-seq data.
Yip, Shun H; Sham, Pak Chung; Wang, Junwen
2018-02-21
Traditional RNA sequencing (RNA-seq) allows the detection of gene expression variations between two or more cell populations through differentially expressed gene (DEG) analysis. However, genes that contribute to cell-to-cell differences are not discoverable with RNA-seq because RNA-seq samples are obtained from a mixture of cells. Single-cell RNA-seq (scRNA-seq) allows the detection of gene expression in each cell. With scRNA-seq, highly variable gene (HVG) discovery allows the detection of genes that contribute strongly to cell-to-cell variation within a homogeneous cell population, such as a population of embryonic stem cells. This analysis is implemented in many software packages. In this study, we compare seven HVG methods from six software packages, including BASiCS, Brennecke, scLVM, scran, scVEGs and Seurat. Our results demonstrate that reproducibility in HVG analysis requires a larger sample size than DEG analysis. Discrepancies between methods and potential issues in these tools are discussed and recommendations are made.
Evaluation of CNT Energy Savers Retrofit Packages Implemented in Multifamily Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farley, Jenne; Ruch, Russell
This evaluation explored the feasibility of designing prescriptive retrofit measure packages for typical Chicago region multifamily buildings in order to achieve 25%-30% source energy savings through the study of three case studies. There is an urgent need to scale up energy efficiency retrofitting of Chicago's multifamily buildings in order to address rising energy costs and a rapidly depleting rental stock. Aimed at retrofit program administrators and building science professionals, this research project investigates the possibility of using prescriptive retrofit packages as a time- and resource-effective approach to the process of retrofitting multifamily buildings.
Evaluation of CNT Energy Savers Retrofit Packages Implemented in Multifamily Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farley, Jenne; Ruch, Russell
This evaluation explored the feasibility of designing prescriptive retrofit measure packages for typical Chicago region multifamily buildings in order to achieve 25%-30% source energy savings through the study of three case studies. There is an urgent need to scale up energy efficiency retrofitting of Chicago's multifamily buildings in order to address rising energy costs and a rapidly depletingrental stock. Aimed at retrofit program administrators and building science professionals, this research project investigates the possibility of using prescriptive retrofit packages as a time- and resource-effective approach to the process of retrofitting multifamily buildings.
NASA Astrophysics Data System (ADS)
Yang, Kun; Xu, Quan-li; Peng, Shuang-yun; Cao, Yan-bo
2008-10-01
Based on the necessity analysis of GIS applications in earthquake disaster prevention, this paper has deeply discussed the spatial integration scheme of urban earthquake disaster loss evaluation models and visualization technologies by using the network development methods such as COM/DCOM, ActiveX and ASP, as well as the spatial database development methods such as OO4O and ArcSDE based on ArcGIS software packages. Meanwhile, according to Software Engineering principles, a solution of Urban Earthquake Emergency Response Decision Support Systems based on GIS technologies have also been proposed, which include the systems logical structures, the technical routes,the system realization methods and function structures etc. Finally, the testing systems user interfaces have also been offered in the paper.
Cognitive Foundry v. 3.0 (OSS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Basilico, Justin; Dixon, Kevin; McClain, Jonathan
2009-11-18
The Cognitive Foundry is a unified collection of tools designed for research and applications that use cognitive modeling, machine learning, or pattern recognition. The software library contains design patterns, interface definitions, and default implementations of reusable software components and algorithms designed to support a wide variety of research and development needs. The library contains three main software packages: the Common package that contains basic utilities and linear algebraic methods, the Cognitive Framework package that contains tools to assist in implementing and analyzing theories of cognition, and the Machine Learning package that provides general algorithms and methods for populating Cognitive Frameworkmore » components from domain-relevant data.« less
Numerical Simulation of Doped Targets for ICF
NASA Astrophysics Data System (ADS)
Phillips, Lee; Gardner, John H.; Bodner, Stephen E.; Colombant, Denis; Klapisch, Marcel; Bar-Shalom, Avraham
1997-11-01
The ablative Rayleigh-Taylor (RT) instability can be reduced by preheating the ablator, thereby reducing the peak density and increasing the mass ablation velocity. The ablator can be preheated with radiation from higher Z dopants.(Gardner, J.H., Bodner, S.E., Dahlburg, J.P., Phys. Fluids 3), 1070 (1991) Dopants also reduce the density gradient at the ablator, which provides a second mechanism to reduce the RT growth rate. We have recently developed a more sophisticated and detailed radiation package that uses opacities generated by an STA code, with non-LTE radiation transport based on the Busquet method. This radiation package has been incorporated into NRL's FAST2D radiation hydrodynamics code, which has been used to evaluate and optimize the use of various dopants that can provide interesting levels of preheat for an ICF target.
The Raid distributed database system
NASA Technical Reports Server (NTRS)
Bhargava, Bharat; Riedl, John
1989-01-01
Raid, a robust and adaptable distributed database system for transaction processing (TP), is described. Raid is a message-passing system, with server processes on each site to manage concurrent processing, consistent replicated copies during site failures, and atomic distributed commitment. A high-level layered communications package provides a clean location-independent interface between servers. The latest design of the package delivers messages via shared memory in a configuration with several servers linked into a single process. Raid provides the infrastructure to investigate various methods for supporting reliable distributed TP. Measurements on TP and server CPU time are presented, along with data from experiments on communications software, consistent replicated copy control during site failures, and concurrent distributed checkpointing. A software tool for evaluating the implementation of TP algorithms in an operating-system kernel is proposed.
Food companies' calorie-reduction pledges to improve U.S. diet.
Slining, Meghan M; Ng, Shu Wen; Popkin, Barry M
2013-02-01
Heretofore, corporate voluntary pledges to improve the health of Americans have been linked neither to explicit measurable commitments nor to a framework for an independent evaluation. The Healthy Weight Commitment Foundation (HWCF), whose members include 16 of the nation's leading consumer packaged goods food and beverage manufacturers, voluntarily pledged to collectively remove 1 trillion calories from their products by 2012 (against a 2007 baseline), and 1.5 trillion calories by 2015. The pledge is designed to reduce the calorie gap commensurate with the HWCF companies' role in the U.S. diet. To date, no system exists for documenting the nutritional and public health impacts of industry-led changes in the food supply on individual diets. The current study represents a unique opportunity to understand how the consumer packaged goods food and beverage sector is changing and how these changes are associated with changes in the American diet. It presents data on national caloric sales from this sector, purchases of these goods by various subpopulations, and methods linking these to individual intakes of Americans. Findings show that HWCF companies accounted for approximately 25% of calories consumed in the U.S. in 2007 and that the 1.5 trillion-calorie pledge (about 14 calories/day/capita) accounts for 0.8% of the calories sold across all consumer packaged goods food and beverage brands in 2007. The authors hope that this evaluation will continue to create models and methods for demonstrating the effects of changes in the food supply on individual diets, particularly among those from vulnerable subpopulations. Copyright © 2013 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.
Biosynthesis and Characterization of AgNPs–Silk/PVA Film for Potential Packaging Application
Tao, Gang; Cai, Rui; Wang, Yejing; Song, Kai; Guo, Pengchao; Zhao, Ping; Zuo, Hua; He, Huawei
2017-01-01
Bionanocomposite packaging materials have a bright future for a broad range of applications in the food and biomedical industries. Antimicrobial packaging is one of the bionanocomposite packaging materials. Silver nanoparticle (AgNP) is one of the most attractive antimicrobial agents for its broad spectrum of antimicrobial activity against microorganisms. However, the traditional method of preparing AgNPs-functionalized packaging material is cumbersome and not environmentally friendly. To develop an efficient and convenient biosynthesis method to prepare AgNPs-modified bionanocomposite material for packaging applications, we synthesized AgNPs in situ in a silk fibroin solution via the reduction of Ag+ by the tyrosine residue of fibroin, and then prepared AgNPs–silk/poly(vinyl alcohol) (PVA) composite film by blending with PVA. AgNPs were synthesized evenly on the surface or embedded in the interior of silk/PVA film. The prepared AgNPs–silk/PVA film exhibited excellent mechanical performance and stability, as well as good antibacterial activity against both Gram-negative and Gram-positive bacteria. AgNPs–silk/PVA film offers more choices to be potentially applied in the active packaging field. PMID:28773026
Biosynthesis and Characterization of AgNPs-Silk/PVA Film for Potential Packaging Application.
Tao, Gang; Cai, Rui; Wang, Yejing; Song, Kai; Guo, Pengchao; Zhao, Ping; Zuo, Hua; He, Huawei
2017-06-17
Bionanocomposite packaging materials have a bright future for a broad range of applications in the food and biomedical industries. Antimicrobial packaging is one of the bionanocomposite packaging materials. Silver nanoparticle (AgNP) is one of the most attractive antimicrobial agents for its broad spectrum of antimicrobial activity against microorganisms. However, the traditional method of preparing AgNPs-functionalized packaging material is cumbersome and not environmentally friendly. To develop an efficient and convenient biosynthesis method to prepare AgNPs-modified bionanocomposite material for packaging applications, we synthesized AgNPs in situ in a silk fibroin solution via the reduction of Ag⁺ by the tyrosine residue of fibroin, and then prepared AgNPs-silk/poly(vinyl alcohol) (PVA) composite film by blending with PVA. AgNPs were synthesized evenly on the surface or embedded in the interior of silk/PVA film. The prepared AgNPs-silk/PVA film exhibited excellent mechanical performance and stability, as well as good antibacterial activity against both Gram-negative and Gram-positive bacteria. AgNPs-silk/PVA film offers more choices to be potentially applied in the active packaging field.
Effectiveness of antimicrobial food packaging materials.
Cooksey, K
2005-10-01
Antimicrobial additives have been used successfully for many years as direct food additives. The literature provides evidence that some of these additives may be effective as indirect food additives incorporated into food packaging materials. Antimicrobial food packaging is directed toward the reduction of surface contamination of processed, prepared foods such as sliced meats and Frankfurter sausages (hot dogs). The use of such packaging materials is not meant to be a substitute for good sanitation practices, but it should enhance the safety of food as an additional hurdle for the growth of pathogenic and/or spoilage microorganisms. Studies have focused on establishing methods for coating low-density polyethylene film or barrier films with methyl cellulose as a carrier for nisin. These films have significantly reduced the presence of Listeria monocytogenes in solutions and in vacuum packaged hot dogs. Other research has focused on the use of chitosan to inhibit L. monocytogenes and chlorine dioxide sachets for the reduction of Salmonella on modified atmosphere-packaged fresh chicken breasts. Overall, antimicrobial packaging shows promise as an effective method for the inhibition of certain bacteria in foods, but barriers to their commercial implementation continue to exist.
ERIC Educational Resources Information Center
Allen, Keith D.; Kuhn, Brett R.; DeHaai, Kristi A.; Wallace, Dustin P.
2013-01-01
The purpose of this investigation was to evaluate the effectiveness of a behavioral treatment package to reduce chronic sleep problems in children with Angelman Syndrome. Participants were five children, 2-11 years-of-age. Parents maintained sleep diaries to record sleep and disruptive nighttime behaviors. Actigraphy was added to provide…
Evaluating Documents: The Case of Patient Package Inserts. Technical Report No. 2.
ERIC Educational Resources Information Center
Krug, Robert E.
To illustrate the types of factors that must be considered in evaluating public documents, this paper analyzes a number of possible outcomes resulting from one type of document, the patient package insert (PPI) designed to provide consumers of prescription drugs with information about the drugs. It first outlines the intended sequence for a PPI:…
A Brief Report on the Effects of a Self-Management Treatment Package on Stereotypic Behavior
ERIC Educational Resources Information Center
Moore, Timothy R.
2009-01-01
We evaluated the effects of a self-management treatment package (SMTP) on the stereotypic behavior of an adolescent with Pervasive Developmental Disorder-Not Otherwise Specified (PDD-NOS). Latency to stereotypy was systematically increased in the training setting (academic) and the effectiveness of the SMTP was evaluated within a multiple-probe…
DOE Office of Scientific and Technical Information (OSTI.GOV)
MCCOY, J.C.
This Safety Analysis Report for Packaging (SARP) provides a technical evaluation of the Sample Pig Transport System as compared to the requirements of the U.S. Department of Energy, Richland Operations Office (RL) Order 5480.1, Change 1, Chapter III. The evaluation concludes that the package is acceptable for the onsite transport of Type B, fissile excepted radioactive materials when used in accordance with this document.
Quality evaluation of packaged acidified vegetables subjected to continuous microwave pasteurization
USDA-ARS?s Scientific Manuscript database
The study evaluated the use of 915 MHz continuous microwave processing with a rotation apparatus for pasteurization of acidified vegetable packages. Broccoli florets, and 1.2 cm cubes of broccoli stems, red bell pepper, and sweetpotato were pre-equilibrated to 1 g/100 g NaCl and 0.38 g/100 mL citric...
Status and Trend of Automotive Power Packaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang, Zhenxian
2012-01-01
Comprehensive requirements in aspects of cost, reliability, efficiency, form factor, weight, and volume for power electronics modules in modern electric drive vehicles have driven the development of automotive power packaging technology intensively. Innovation in materials, interconnections, and processing techniques is leading to enormous improvements in power modules. In this paper, the technical development of and trends in power module packaging are evaluated by examining technical details with examples of industrial products. The issues and development directions for future automotive power module packaging are also discussed.
Safety analysis report for packaging (onsite) multicanister overpack cask
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edwards, W.S.
1997-07-14
This safety analysis report for packaging (SARP) documents the safety of shipments of irradiated fuel elements in the MUlticanister Overpack (MCO) and MCO Cask for a highway route controlled quantity, Type B fissile package. This SARP evaluates the package during transfers of (1) water-filled MCOs from the K Basins to the Cold Vacuum Drying Facility (CVDF) and (2) sealed and cold vacuum dried MCOs from the CVDF in the 100 K Area to the Canister Storage Building in the 200 East Area.
Biocidal packaging for pharmaceuticals, foods, and other perishables.
Larson, Alyssa M; Klibanov, Alexander M
2013-01-01
Many consumer goods must be protected from bacterial and fungal colonization to ensure their integrity and safety. By making these items' packaging biocidal, the interior environment can be preserved from microbial spoilage without altering the products themselves. Herein we briefly review this concept, referred to as active packaging, and discuss existing methods for constructing active packaging systems. They are based on either packaging materials that release biocides or those that are themselves intrinsically biocidal (or biostatic), with numerous variations within each category.
Gray, Janet M.; Engel, Connie L.; Rawsthorne, Teresa W.; Dodson, Robin E.; Ackerman, Janet M.; Rizzo, Jeanne; Nudelman, Janet L.; Brody, Julia Green
2011-01-01
Background: Bisphenol A (BPA) and bis(2-ethylhexyl) phthalate (DEHP) are high-production-volume chemicals used in plastics and resins for food packaging. They have been associated with endocrine disruption in animals and in some human studies. Human exposure sources have been estimated, but the relative contribution of dietary exposure to total intake has not been studied empirically. Objectives: To evaluate the contribution of food packaging to exposure, we measured urinary BPA and phthalate metabolites before, during, and after a “fresh foods” dietary intervention. Methods: We selected 20 participants in five families based on self-reported use of canned and packaged foods. Participants ate their usual diet, followed by 3 days of “fresh foods” that were not canned or packaged in plastic, and then returned to their usual diet. We collected evening urine samples over 8 days in January 2010 and composited them into preintervention, during intervention, and postintervention samples. We used mixed-effects models for repeated measures and Wilcoxon signed-rank tests to assess change in urinary levels across time. Results: Urine levels of BPA and DEHP metabolites decreased significantly during the fresh foods intervention [e.g., BPA geometric mean (GM), 3.7 ng/mL preintervention vs. 1.2 ng/mL during intervention; mono-(2-ethyl-5-hydroxy hexyl) phthalate GM, 57 ng/mL vs. 25 ng/mL]. The intervention reduced GM concentrations of BPA by 66% and DEHP metabolites by 53–56%. Maxima were reduced by 76% for BPA and 93–96% for DEHP metabolites. Conclusions: BPA and DEHP exposures were substantially reduced when participants’ diets were restricted to food with limited packaging. PMID:21450549
Elliott, Charlene D; Conlon, Martin J
2011-03-01
To critically examine child-oriented packaged food products sold in Canada for their sodium content, and to assess them light of intake recommendations, the current policy context and suggested targets. Baby/toddler foods (n 186) and child-oriented packaged foods (n 354) were coded for various attributes (including sodium). Summary statistics were created for sodium, then the children's food products were compared with the UK Food Standards Agency (FSA) 'targets' for sodium in packaged foods. Also assessed were the products' per-serving sodium levels were assessed in light of the US Institute of Medicine's dietary reference intakes and Canada's Food Guide. Calgary, Alberta, Canada. None. Twenty per cent of products could be classified as having high sodium levels. Certain sub-categories of food (i.e. toddler entrées, children's packaged lunches, soups and canned pastas) were problematic. Significantly, when scaled in according to Schedule M or viewed in light of the serving sizes on the Nutrition Facts table, the sodium level in various dry goods products generally fell within, and below, the Adequate Intake (AI)/Tolerable Upper Intake Level (UL) band for sodium. When scaled in accordance with the UK FSA targets, however, none of the (same) products met the targets. In light of AI/UL thresholds based on age and per-serving cut-offs, packaged foodstuffs for youngsters fare relatively well, with the exception of some problematic areas. 'Stealth sodium' and 'subtle sodium' are important considerations; so is use of the FSA's scaling method to evaluate sodium content, because it is highly sensitive to the difference between the reference amount and the actual real-world serving size for the product being considered.
Santamaria-Fernandez, Rebeca; Wolff, Jean-Claude
2010-07-30
The potential of high-precision calcium and lead isotope ratio measurements using laser ablation coupled to multicollector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) to aid distinction between four genuine and five counterfeit pharmaceutical packaging samples and further classification of counterfeit packaging samples has been evaluated. We highlight the lack of reference materials for LA-MC-ICP-MS isotope ratio measurements in solids. In this case the problem is minimised by using National Institute of Standards and Technology Standard Reference Material (NIST SRM) 915a calcium carbonate (as solid pellets) and NIST SRM610 glass disc for sample bracketing external standardisation. In addition, a new reference material, NIST SRM915b calcium carbonate, has been characterised in-house for Ca isotope ratios and is used as a reference sample. Significant differences have been found between genuine and counterfeit samples; the method allows detection of counterfeits and aids further classification of packaging samples. Typical expanded uncertainties for measured-corrected Ca isotope ratio values ((43)Ca/(44)Ca and (42)Ca/(44)Ca) were found to be below 0.06% (k = 2, 95% confidence) and below 0.2% for measured-corrected Pb isotope ratios ((207)Pb/(206)Pb and (208)Pb/(206)Pb). This is the first time that Ca isotope ratios have been measured in packaging materials using LA coupled to a multicollector (MC)-ICP-MS instrument. The use of LA-MC-ICP-MS for direct measurement of Ca and Pb isotopic variations in cardboard/ink in packaging has definitive potential to aid counterfeit detection and classification. Copyright 2010 John Wiley & Sons, Ltd.
Lu, Haixia; Zhu, Junli; Li, Jianrong; Chen, Jinru
2015-06-01
Contaminated leafy green vegetables have been linked to several outbreaks of human gastrointestinal infections. Antimicrobial interventions that are adoptable by the fresh produce industry for control of pathogen contamination are in great demand. This study was undertaken to evaluate the efficacy of sustained active packaging on control of Escherichia coli O157:H7 and total aerobic bacteria on lettuce. Commercial Iceberg lettuce was inoculated with a 3-strain mixture of E. coli O157:H7 at 10(2) or 10(4) CFU/g. The contaminated lettuce and un-inoculated controls were placed respectively in 5 different active packaging structures. Traditional, nonactive packaging structure was included as controls. Packaged lettuce was stored at 4, 10, or 22 °C for 3 wk and sampled weekly for the population of E. coli O157:H7 and total aerobic bacteria. Results showed that packaging structures with ClO2 generator, CO2 generator, or one of the O2 scavengers effectively controlled the growth of E. coli O157:H7 and total aerobic bacteria under all storage conditions. Packaging structure with the ClO2 generator was most effective and no E. coli O157:H7 was detected in samples packaged in this structure except for those that were inoculated with 4 log CFU/g of E. coli O157:H7 and stored at 22 °C. Packaging structures with an oxygen scavenger and the allyl isothiocyanate generator were mostly ineffective in control of the growth of the bacteria on Iceberg lettuce. The research suggests that some of the packaging structures evaluated in the study can be used to control the presence of foodborne pathogens on leafy green vegetables. © 2015 Institute of Food Technologists®
Cwiek-Ludwicka, Kazimiera; Pawlicka, Marzena; Starski, Andrzej; Półtorak, Hanna; Karłowski, Kazimierz
2011-01-01
The aim of this study was to identify of primary aromatic amines (PAAs) and to determine their migration from plastic food packaging. The magnitude of the migration of these substances from plastic food packaging consists a base for the evaluation of their compliance with the requirements of EU legislation and hazard for human health taking into account their migration into food. The unprinted and printed multi-layer plastic packaging (laminates), domestic and imported, were examined in these studies. PAAs migration tests from the laminates into food simulant (3% acetic acid) was performed according to the appropriate procedures recommended in the EU for testing migration from food contact articles under standard conditions reflecting the real use of laminates (10 days, 40 degrees C) and under ,, worst case scenario" conditions (2 h, 70 degrees C). PAAs present in migration solutions were concentrated on SPE columns and then seven PAAs (aniline, 1,3-phenylenediamine, 2, 6-toluenediamine, 2,4-toluenediamine, 4,4'-oxydianiline, 4,4'-methylenedianiline and 3,3 '-dimethylbenzidyne) were identified and determined by previously validated HPLC-DAD method. Depending on the migration conditions the PAAs content was different. When the "worst case scenario" conditions were applied the migration of 4,4 '-methylenedianiline (4,4 '-MDA) ranged from below detection limit (LOD = 0.51 microg/kg) up to 9.86 microg/kg, and aniline was released in the range from below detection limit (LOD = 0,98 microg/kg) up to 7.04 microg/kg. In two laminate samples of eight examined, the sum of PAAs (aniline and 4,4'-MDA) was 13.32 microg/kg and 14.72 microg/kg showing that the permitted limit (10 microg/kg) was exceeded. In the standard conditions, the migration of aniline and 4,4'-MDA was significantly lower Regarding the carcinogenic potential of PAAs, the laminates causing the amines migration above the permitted limit should not be used as food packaging.
Bayesian Hierarchical Random Effects Models in Forensic Science.
Aitken, Colin G G
2018-01-01
Statistical modeling of the evaluation of evidence with the use of the likelihood ratio has a long history. It dates from the Dreyfus case at the end of the nineteenth century through the work at Bletchley Park in the Second World War to the present day. The development received a significant boost in 1977 with a seminal work by Dennis Lindley which introduced a Bayesian hierarchical random effects model for the evaluation of evidence with an example of refractive index measurements on fragments of glass. Many models have been developed since then. The methods have now been sufficiently well-developed and have become so widespread that it is timely to try and provide a software package to assist in their implementation. With that in mind, a project (SAILR: Software for the Analysis and Implementation of Likelihood Ratios) was funded by the European Network of Forensic Science Institutes through their Monopoly programme to develop a software package for use by forensic scientists world-wide that would assist in the statistical analysis and implementation of the approach based on likelihood ratios. It is the purpose of this document to provide a short review of a small part of this history. The review also provides a background, or landscape, for the development of some of the models within the SAILR package and references to SAILR as made as appropriate.
Wills, K M; Mitacek, R M; Mafi, G G; VanOverbeke, D L; Jaroni, D; Jadeja, R; Ramanathan, R
2017-12-01
The objective was to evaluate the effects of wet-aging, rosemary-enhancement, and modified atmospheric packaging on the color of dark-cutting beef during simulated retail display. No-roll dark-cutting strip loins ( = 12; pH > 6.0) were selected from a commercial packing plant within 3 d postharvest. Using a balanced incomplete block design, dark-cutting loins were sectioned in half, and assigned to 1 of 3 aging periods: 7, 14, or 21 d. After respective aging, each aged section was divided into 3 equal parts, and randomly assigned to 1 of 3 enhancement treatments: nonenhanced dark-cutting, dark-cutter enhanced with 0.1% rosemary, and dark-cutter enhanced with 0.2% rosemary. Following enhancement, steaks were randomly assigned to 1 of 3 packaging treatments: high-oxygen modified atmospheric packaging (HiOx-MAP; 80% O and 20% CO), carbon monoxide modified atmospheric packaging (CO-MAP; 0.4% CO, 69.6% N, and 30% CO), and polyvinyl chloride overwrap (PVC; 20% O). Instrumental and visual color measurements were recorded during 5 d simulated retail display. Lipid oxidation was determined utilizing the thiobarbituric acid reactive substances (TBARS) method. There was a significant packaging × enhancement × display time interaction for values and chroma ( 0.001). On d 0 of display, dark-cutting steaks enhanced with 0.1% and 0.2% rosemary and packaged in HiOx-MAP had greater ( 0.001) values and chroma than other dark-cutting packaging/enhancement treatments. A significant packaging × enhancement × display time interaction resulted for values ( 0.001). Dark-cutting steaks enhanced with 0.2% rosemary and packaged in HiOx-MAP was lighter ( 0.001; greater values) than other dark-cutting treatments on d 5 of display. There were no differences ( 0.34) in discoloration scores on d 5 among different dark-cutting treatments when steaks were packaged in HiOx- and CO-MAP. There was an aging period × enhancement × packaging interaction ( < 0.0033) for lipid oxidation. On d 0 of display, there were no differences ( 0.54) in TBARS values between different aging periods and enhancement treatments. Dark-cutting steaks enhanced with 0.2% rosemary had lower ( 0.001) TBARS values than 0.1% rosemary on d 5 when aged for 21 d and in HiOx-MAP. The results suggest that rosemary enhancement with CO- or HiOx-MAP has the potential to improve the surface color of dark-cutting beef.
AE (Acoustic Emission) for Flip-Chip CGA/FCBGA Defect Detection
NASA Technical Reports Server (NTRS)
Ghaffarian, Reza
2014-01-01
C-mode scanning acoustic microscopy (C-SAM) is a nondestructive inspection technique that uses ultrasound to show the internal feature of a specimen. A very high or ultra-high-frequency ultrasound passes through a specimen to produce a visible acoustic microimage (AMI) of its inner features. As ultrasound travels into a specimen, the wave is absorbed, scattered or reflected. The response is highly sensitive to the elastic properties of the materials and is especially sensitive to air gaps. This specific characteristic makes AMI the preferred method for finding "air gaps" such as delamination, cracks, voids, and porosity. C-SAM analysis, which is a type of AMI, was widely used in the past for evaluation of plastic microelectronic circuits, especially for detecting delamination of direct die bonding. With the introduction of the flip-chip die attachment in a package; its use has been expanded to nondestructive characterization of the flip-chip solder bumps and underfill. Figure 1.1 compares visual and C-SAM inspection approaches for defect detection, especially for solder joint interconnections and hidden defects. C-SAM is specifically useful for package features like internal cracks and delamination. C-SAM not only allows for the visualization of the interior features, it has the ability to produce images on layer-by-layer basis. Visual inspection; however, is only superior to C-SAM for the exposed features including solder dewetting, microcracks, and contamination. Ideally, a combination of various inspection techniques - visual, optical and SEM microscopy, C-SAM, and X-ray - need to be performed in order to assure quality at part, package, and system levels. This reports presents evaluations performed on various advanced packages/assemblies, especially the flip-chip die version of ball grid array/column grid array (BGA/CGA) using C-SAM equipment. Both external and internal equipment was used for evaluation. The outside facility provided images of the key features that could be detected using the most advanced C-SAM equipment with a skilled operator. Investigation continued using in-house equipment with its limitations. For comparison, representative X-rays of the assemblies were also gathered to show key defect detection features of these non-destructive techniques. Key images gathered and compared are: Compared the images of 2D X-ray and C-SAM for a plastic LGA assembly showing features that could be detected by either NDE technique. For this specific case, X-ray was a clear winner. Evaluated flip-chip CGA and FCBGA assemblies with and without heat sink by C-SAM. Only the FCCGA package that had no heat sink could be fully analyzed for underfill and bump quality. Cross-sectional microscopy did not revealed peripheral delamination features detected by C-SAM. Analyzed a number of fine pitch PBGA assemblies by C-SAM. Even though the internal features of the package assemblies could be detected, C-SAM was unable to detect solder joint failure at either the package or board level. Twenty times touch ups by solder iron with 700degF tip temperature, each with about 5 second duration, did not induce defects to be detected by C-SAM images. Other techniques need to be considered to induce known defects for characterization. Given NASA's emphasis on the use of microelectronic packages and assemblies and quality assurance on workmanship defect detection, understanding key features of various inspection systems that detect defects in the early stages of package and assembly is critical to developing approaches that will minimize future failures. Additional specific, tailored non-destructive inspection approaches could enable low-risk insertion of these advanced electronic packages having hidden and fine features.
Obstruction of critical information on over-the-counter medication packages by external tags.
Sansgiry, Sujit S; Pawaskar, Manjiri D
2005-02-01
Over-the-counter (OTC) medication packages are important sources of information for consumers during product selection and use. Consumers may not be able to access information from OTC packages if external tags, namely price or anti-theft tags, are improperly placed. To determine the amount and type of information concealed by anti-theft tags and price tags affixed on OTC drug packages. A field study was performed by evaluating packages containing acetaminophen and combinations of acetaminophen in stores located in Houston. Five packages for 4 products selected from each store after an initial survey for presence of an external tag were examined. A data collection sheet was prepared that extracted the type and amount of information concealed by these tags. Data were analyzed by performing descriptive analyses to provide an understanding of the information obscured. A total of 24 stores were considered in the study, and 67 products and 285 packages were evaluated. External tags, both anti-theft and price tags, obscured significant amounts of information on the principal display panel (53.4%) and the Drug Facts panel (47.7%) of OTC packages. These tags concealed crucial information on various aspects of labels such as brand names (42.3%), product description (36.3%), warnings (51.5%), uses (10.4%), and purposes (7.2%). Results suggest that improper use of external tags clearly obscured important information on OTC medication packages necessary for consumers to make informed decisions regarding product selection and use. Tagging practices should be altered to allow consumers full access to drug information on the product.
Shillcutt, Samuel D; Waters, Hugh R; Haider, Sabbir; El Arifeen, Shams; Mannan, Ishtiaq; Seraji, Habibur R; Shah, Rasheduzzaman; Darmstadt, Gary L; Wall, Steve N; Williams, Emma K; Black, Robert E; Santosham, Mathuram; Baqui, Abdullah H
2013-01-01
Abstract Objective To evaluate and compare the cost-effectiveness of two strategies for neonatal care in Sylhet division, Bangladesh. Methods In a cluster-randomized controlled trial, two strategies for neonatal care – known as home care and community care – were compared with existing services. For each study arm, economic costs were estimated from a societal perspective, inclusive of programme costs, provider costs and household out-of-pocket payments on care-seeking. Neonatal mortality in each study arm was determined through household surveys. The incremental cost-effectiveness of each strategy – compared with that of the pre-existing levels of maternal and neonatal care – was then estimated. The levels of uncertainty in our estimates were quantified through probabilistic sensitivity analysis. Findings The incremental programme costs of implementing the home-care package were 2939 (95% confidence interval, CI: 1833–7616) United States dollars (US$) per neonatal death averted and US$ 103.49 (95% CI: 64.72–265.93) per disability-adjusted life year (DALY) averted. The corresponding total societal costs were US$ 2971 (95% CI: 1844–7628) and US$ 104.62 (95% CI: 65.15–266.60), respectively. The home-care package was cost-effective – with 95% certainty – if healthy life years were valued above US$ 214 per DALY averted. In contrast, implementation of the community-care strategy led to no reduction in neonatal mortality and did not appear to be cost-effective. Conclusion The home-care package represents a highly cost-effective intervention strategy that should be considered for replication and scale-up in Bangladesh and similar settings elsewhere. PMID:24115797
Yavorska, Olena O; Burgess, Stephen
2017-12-01
MendelianRandomization is a software package for the R open-source software environment that performs Mendelian randomization analyses using summarized data. The core functionality is to implement the inverse-variance weighted, MR-Egger and weighted median methods for multiple genetic variants. Several options are available to the user, such as the use of robust regression, fixed- or random-effects models and the penalization of weights for genetic variants with heterogeneous causal estimates. Extensions to these methods, such as allowing for variants to be correlated, can be chosen if appropriate. Graphical commands allow summarized data to be displayed in an interactive graph, or the plotting of causal estimates from multiple methods, for comparison. Although the main method of data entry is directly by the user, there is also an option for allowing summarized data to be incorporated from the PhenoScanner database of genotype-phenotype associations. We hope to develop this feature in future versions of the package. The R software environment is available for download from [https://www.r-project.org/]. The MendelianRandomization package can be downloaded from the Comprehensive R Archive Network (CRAN) within R, or directly from [https://cran.r-project.org/web/packages/MendelianRandomization/]. Both R and the MendelianRandomization package are released under GNU General Public Licenses (GPL-2|GPL-3). © The Author 2017. Published by Oxford University Press on behalf of the International Epidemiological Association.
A QR code identification technology in package auto-sorting system
NASA Astrophysics Data System (ADS)
di, Yi-Juan; Shi, Jian-Ping; Mao, Guo-Yong
2017-07-01
Traditional manual sorting operation is not suitable for the development of Chinese logistics. For better sorting packages, a QR code recognition technology is proposed to identify the QR code label on the packages in package auto-sorting system. The experimental results compared with other algorithms in literatures demonstrate that the proposed method is valid and its performance is superior to other algorithms.
Inhibitory effects of cinnamon and clove essential oils on mold growth on baked foods.
Ju, Jian; Xu, Xiaomiao; Xie, Yunfei; Guo, Yahui; Cheng, Yuliang; Qian, He; Yao, Weirong
2018-02-01
This study evaluated the minimum inhibition concentration (MIC) and minimum lethal concentration (MLC) of cinnamon and clove essential oils against mold growth on green bean cake and finger citron crisp cake, and also examined the effects of these two essential oils and their application methods on the shelf life of the baked products in normal and vacuum packages by accelerated storage test. The results showed that the MIC of cinnamon and clove essential oils against molds were 0.21-0.83 and 0.21-1.67μL/mL, respectively and the MLC were 0.42-0.83 and 0.83-1.67μL/mL, respectively. In normal package cinnamon and clove essential oils could prolong the shelf life of green bean cake 9-10 and 3-4days, respectively and could prolong the shelf life of finger citron crisp cake 5-6 and 2-3days, respectively. And in vacuum package they were 15-16, 8-9, 10-12 and 7-9days, respectively in turn. Copyright © 2017. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Shen, Weidian
2005-03-01
Plastic film packaging is widely used these days, especially in the convenience food industry due to its flexibility, boilability, and microwavability. Almost every package is printed with ink. The adhesion of ink on plastic films merits increasing attention to ensure quality packaging. However, inks and plastic films are polymeric materials with complicated molecular structures. The thickness of the jelly-like ink is only 500nm or less, and the thickness of the soft and flexible film is no more than 50μm, which make the quantitative measurement of their adhesion very challenging. Up to now, no scientific quantitative measurement method for the adhesion of ink on plastic films has been documented. We have tried a technique, in which a Nano-Indenter and a Scanning Probe Microscope were used to evaluate the adhesion strength of ink deposited on plastic films, quantitatively, as well as examine the configurations of adhesion failure. It was helpful in better understanding the adhesion mechanism, thus giving direction as to how to improve the adhesion.
Software engineering the mixed model for genome-wide association studies on large samples.
Zhang, Zhiwu; Buckler, Edward S; Casstevens, Terry M; Bradbury, Peter J
2009-11-01
Mixed models improve the ability to detect phenotype-genotype associations in the presence of population stratification and multiple levels of relatedness in genome-wide association studies (GWAS), but for large data sets the resource consumption becomes impractical. At the same time, the sample size and number of markers used for GWAS is increasing dramatically, resulting in greater statistical power to detect those associations. The use of mixed models with increasingly large data sets depends on the availability of software for analyzing those models. While multiple software packages implement the mixed model method, no single package provides the best combination of fast computation, ability to handle large samples, flexible modeling and ease of use. Key elements of association analysis with mixed models are reviewed, including modeling phenotype-genotype associations using mixed models, population stratification, kinship and its estimation, variance component estimation, use of best linear unbiased predictors or residuals in place of raw phenotype, improving efficiency and software-user interaction. The available software packages are evaluated, and suggestions made for future software development.
Klehm, B J; King, D A; Dilger, A C; Shackelford, S D; Boler, D D
2018-05-04
The objective was to determine the interactions between packaging type and degree of doneness on sensory traits of pork loins classified based on the newly proposed USDA quality grades. A total of 144 loins were selected from 2 groups of pigs (lean growth or meat quality production focus) to represent as much variation in visual color and marbling as possible. Selection was achieved with a VQG grading camera. The ventral surface of the loins was evaluated for loin quality traits at 1 d postmortem. At 2 d postmortem loins were sliced into 28-mm-thick chops. Chop within each loin was randomly assigned to either individual vacuum packages or to individual Styrofoam trays and overwrapped in polyvinyl chloride (PVC) oxygen permeable film. Overwrapped PVC packages were then placed in bulk packages and flushed with a gas mixture that contained approximately 0.4% carbon monoxide, 30% carbon dioxide, and 80% nitrogen. Vacuum-packaged chops were aged until 14 d postmortem. Chops packaged in PVC overwrap were aged until 9 d postmortem in the bulk packages, then placed on simulated retail display until 14 d postmortem. Chops from each packaging type were cooked to an internal temperature of either 63 °C or 71 °C for the evaluation of slice shear force (SSF) or for evaluation of tenderness, juiciness, and flavor by a trained panel. Data were analyzed as split-split plot design with production focus of the pigs, proposed USDA quality grade, packaging type, and degree of doneness as fixed effects. While there were main effect differences between production focuses, there were no interactions with production focus. There were also no 3-way (P ≥ 0.19) interactions and only one 2-way interaction among quality grade, packaging type, or degree of doneness. There were no differences in sensory tenderness (P = 0.30), juiciness (P = 0.49), flavor (P = 0.89), SSF (P = 0.13), or cook loss (P = 0.06) among USDA quality grades. There were no differences in sensory tenderness (P = 0.06), juiciness (P = 0.32), flavor (P = 0.74), SSF (P = 0.99), or cook loss (P = 0.12) between chops aged in vacuum packages or PVC packages. Chops cooked to 63 °C were 4.6% more tender (P < 0.0001), 10.1% juicier (P < 0.0001), and 2.9% less flavorful (P = 0.01) than chops cooked to 71 °C. These data suggest that cooking chops to 63 °C rather than 71 °C was a more effective way to improve tenderness and juiciness than selecting chops of a certain quality grade or altering packaging postmortem.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaenko, Alexander; Windus, Theresa L.; Sosonkina, Masha
2012-10-19
The design and development of scientific software components to provide an interface to the effective fragment potential (EFP) methods are reported. Multiscale modeling of physical and chemical phenomena demands the merging of software packages developed by research groups in significantly different fields. Componentization offers an efficient way to realize new high performance scientific methods by combining the best models available in different software packages without a need for package readaptation after the initial componentization is complete. The EFP method is an efficient electronic structure theory based model potential that is suitable for predictive modeling of intermolecular interactions in large molecularmore » systems, such as liquids, proteins, atmospheric aerosols, and nanoparticles, with an accuracy that is comparable to that of correlated ab initio methods. The developed components make the EFP functionality accessible for any scientific component-aware software package. The performance of the component is demonstrated on a protein interaction model, and its accuracy is compared with results obtained with coupled cluster methods.« less
Chen, Po-Yu
2014-01-01
The validness of the expiration dates (validity period) that manufacturers provide on food product labels is a crucial food safety problem. Governments must study how to use their authority by implementing fair awards and punishments to prompt manufacturers into adopting rigorous considerations, such as the effect of adopting new storage methods for extending product validity periods on expected costs. Assuming that a manufacturer sells fresh food or drugs, this manufacturer must respond to current stochastic demands at each unit of time to determine the purchase amount of products for sale. If this decision maker is capable and an opportunity arises, new packaging methods (e.g., aluminum foil packaging, vacuum packaging, high-temperature sterilization after glass packaging, or packaging with various degrees of dryness) or storage methods (i.e., adding desiccants or various antioxidants) can be chosen to extend the validity periods of products. To minimize expected costs, this decision maker must be aware of the processing costs of new storage methods, inventory standards, inventory cycle lengths, and changes in relationships between factors such as stochastic demand functions in a cycle. Based on these changes in relationships, this study established a mathematical model as a basis for discussing the aforementioned topics.
Orsi, Rebecca
2017-02-01
Concept mapping is now a commonly-used technique for articulating and evaluating programmatic outcomes. However, research regarding validity of knowledge and outcomes produced with concept mapping is sparse. The current study describes quantitative validity analyses using a concept mapping dataset. We sought to increase the validity of concept mapping evaluation results by running multiple cluster analysis methods and then using several metrics to choose from among solutions. We present four different clustering methods based on analyses using the R statistical software package: partitioning around medoids (PAM), fuzzy analysis (FANNY), agglomerative nesting (AGNES) and divisive analysis (DIANA). We then used the Dunn and Davies-Bouldin indices to assist in choosing a valid cluster solution for a concept mapping outcomes evaluation. We conclude that the validity of the outcomes map is high, based on the analyses described. Finally, we discuss areas for further concept mapping methods research. Copyright © 2016 Elsevier Ltd. All rights reserved.
Interactive Multimedia Package in Ameliorating Communicative Skill in English
ERIC Educational Resources Information Center
Singaravelu, G.
2011-01-01
The study enlightens the effectiveness of Interactive-Multimedia Package in developing communicative skill in English at standard VI. Present methods of developing communicative skill are ineffective to the students in improving their communicative competencies in English. Challenging interactive Multimedia Package helps to enhance the…
Type of packaging affects the colour stability of vitamin E enriched beef.
Nassu, Renata T; Uttaro, Bethany; Aalhus, Jennifer L; Zawadski, Sophie; Juárez, Manuel; Dugan, Michael E R
2012-12-01
Colour stability is a very important parameter for meat retail display, as appearance of the product is the deciding factor for consumers at time of purchase. This study investigated the possibility of extending appearance shelf-life through the combined use of packaging method (overwrapping - OVER, modified atmosphere - MAP, vacuum skin packaging - VSP and a combination of modified atmosphere and vacuum skin packaging - MAPVSP) and antioxidants (vitamin E enriched beef). Retail attributes (appearance, lean colour, % surface discolouration), as well as colour space analysis of images for red, green and blue parameters were measured over 18days. MAPVSP provided the most desirable retail appearance during the first 4days of retail display, while VSP-HB had the best colour stability. Overall, packaging type was more influential than α-tocopherol levels on meat colour stability, although α-tocopherol levels (>4μgg(-1) meat) had a protective effect when using high oxygen packaging methods. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.
Child-Resistant Packaging for E-Liquid: A Review of US State Legislation.
Frey, Leslie T; Tilburg, William C
2016-02-01
A growing number of states have introduced or enacted legislation requiring child-resistant packaging for e-liquid containers; however, these laws involve varying terms, packaging standards, and enforcement provisions, raising concerns about their effectiveness. We evaluated bills against 4 benchmarks: broad product definitions that contemplate future developments in the market, citations to a specific packaging standard, stated penalties for violations, and express grants of authority to a state entity to enforce the packaging requirements. Our findings showed that 3 states meet all 4 benchmarks in their enacted legislation. We encourage states to consider these benchmarks when revising statutes or drafting future legislation.
Child-Resistant Packaging for E-Liquid: A Review of US State Legislation
Tilburg, William C.
2016-01-01
A growing number of states have introduced or enacted legislation requiring child-resistant packaging for e-liquid containers; however, these laws involve varying terms, packaging standards, and enforcement provisions, raising concerns about their effectiveness. We evaluated bills against 4 benchmarks: broad product definitions that contemplate future developments in the market, citations to a specific packaging standard, stated penalties for violations, and express grants of authority to a state entity to enforce the packaging requirements. Our findings showed that 3 states meet all 4 benchmarks in their enacted legislation. We encourage states to consider these benchmarks when revising statutes or drafting future legislation. PMID:26691114
Evaluation of RDBMS packages for use in astronomy
NASA Technical Reports Server (NTRS)
Page, C. G.; Davenhall, A. C.
1992-01-01
Tabular data sets arise in many areas of astronomical data analysis, from raw data (such as photon event lists) to final results (such as source catalogs). The Starlink catalog access and reporting package, SCAR, was originally developed to handle IRAS data and it has been the principal relational DBMS in the Starlink software collection for several years. But SCAR has many limitations and is VMS-specific, while Starlink is in transition from VMS to Unix. Rather than attempt a major re-write of SCAR for Unix, it seemed more sensible to see whether any existing database packages are suitable for general astronomical use. The authors first drew up a list of desirable properties for such a system and then used these criteria to evaluate a number of packages, both free ones and those commercially available. It is already clear that most commercial DBMS packages are not very well suited to the requirements; for example, most cannot carry out efficiently even fairly basic operations such as joining two catalogs on an approximate match of celestial positions. This paper reports the results of the evaluation exercise and notes the problems in using a standard DBMS package to process scientific data. In parallel with this the authors have started to develop a simple database engine that can handle tabular data in a range of common formats including simple direct-access files (such as SCAR and Exosat DBMS tables) and FITS tables (both ASCII and binary).
Vexler, Albert; Tanajian, Hovig; Hutson, Alan D
In practice, parametric likelihood-ratio techniques are powerful statistical tools. In this article, we propose and examine novel and simple distribution-free test statistics that efficiently approximate parametric likelihood ratios to analyze and compare distributions of K groups of observations. Using the density-based empirical likelihood methodology, we develop a Stata package that applies to a test for symmetry of data distributions and compares K -sample distributions. Recognizing that recent statistical software packages do not sufficiently address K -sample nonparametric comparisons of data distributions, we propose a new Stata command, vxdbel, to execute exact density-based empirical likelihood-ratio tests using K samples. To calculate p -values of the proposed tests, we use the following methods: 1) a classical technique based on Monte Carlo p -value evaluations; 2) an interpolation technique based on tabulated critical values; and 3) a new hybrid technique that combines methods 1 and 2. The third, cutting-edge method is shown to be very efficient in the context of exact-test p -value computations. This Bayesian-type method considers tabulated critical values as prior information and Monte Carlo generations of test statistic values as data used to depict the likelihood function. In this case, a nonparametric Bayesian method is proposed to compute critical values of exact tests.
Fenko, Anna; de Vries, Roxan; van Rompay, Thomas
2018-01-01
This study investigates the relative impact of textual claims and visual metaphors displayed on the product’s package on consumers’ flavor experience and product evaluation. For consumers, strength is one of the most important sensory attributes of coffee. The 2 × 3 between-subjects experiment (N = 123) compared the effects of visual metaphor of strength (an image of a lion located either on top or on the bottom of the package of coffee beans) and the direct textual claim (“extra strong”) on consumers’ responses to coffee, including product expectation, flavor evaluation, strength perception and purchase intention. The results demonstrate that both the textual claim and the visual metaphor can be efficient in communicating the product attribute of strength. The presence of the image positively influenced consumers’ product expectations before tasting. The textual claim increased the perception of strength of coffee and the purchase intention of the product. The location of the image also played an important role in flavor perception and purchase intention. The image located on the bottom of the package increased the perceived strength of coffee and purchase intention of the product compared to the image on top of the package. This result could be interpreted from the perspective of the grounded cognition theory, which suggests that a picture in the lower part of the package would automatically activate the “strong is heavy” metaphor. As heavy objects are usually associated with a position on the ground, this would explain why perceiving a visually heavy package would lead to the experience of a strong coffee. Further research is needed to better understand the relationships between a metaphorical image and its spatial position in food packaging design. PMID:29459840
NASA Technical Reports Server (NTRS)
Du, B.; Daniels, V.; Crady, C.; Putcha, L.
2011-01-01
This slide presentation reviews preliminary results of the program to evaluate Commercial Off the Shelf (COTS) packaging materials for pharmaceutical stability. The need for improved packaging is due to possible changes in chemical and/or physical properties of the drugs, which cause reported reduced potency and/or altered bioavailability and decreased efficacy.
ERIC Educational Resources Information Center
Pennington, Robert C.; Foreman, Lindsay Hugg; Gurney, Beth Newberry
2018-01-01
In the current study, we investigated the effects of an instructional package (i.e., response prompting, sentence frames) on sentence writing for three middle school participants (ages 12-13) with moderate to severe disabilities. We employed a multiple probe across behaviors design to evaluate the efficacy of the intervention package and also used…
Emerson, C; Lipke, V; Kapata, N; Mwananyambe, N; Mwinga, A; Garekwe, M; Lanje, S; Moshe, Y; Pals, S L; Nakashima, A K; Miller, B
2016-07-01
Out-patient human immunodeficiency virus (HIV) care and treatment clinics in Zambia and Botswana, countries with a high burden of HIV and TB infection. To develop a tuberculosis infection control (TB IC) training and implementation package and evaluate the implementation of TB IC activities in facilities implementing the package. Prospective program evaluation of a TB IC training and implementation package using a standardized facility risk assessment tool, qualitative interviews with facility health care workers and measures of pre- and post-test performance. A composite measure of facility performance in TB IC improved from 32% at baseline to 50% at 1 year among eight facilities in Zambia, and from 27% to 80% at 6 months among 10 facilities in Botswana. Although there was marked improvement in indicators of managerial, administrative and environmental controls, key ongoing challenges remained in ensuring access to personal protective equipment and implementing TB screening in health care workers. TB IC activities at out-patient HIV clinics in Zambia and Botswana improved after training using the implementation package. Continued infrastructure support, as well as monitoring and evaluation, are needed to support the scale-up and sustainability of TB IC programs in facilities in low-resource countries.
49 CFR 178.608 - Vibration standard.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 3 2011-10-01 2011-10-01 false Vibration standard. 178.608 Section 178.608... Packagings and Packages § 178.608 Vibration standard. (a) Each packaging must be capable of withstanding, without rupture or leakage, the vibration test procedure outlined in this section. (b) Test method. (1...
49 CFR 178.608 - Vibration standard.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 3 2013-10-01 2013-10-01 false Vibration standard. 178.608 Section 178.608... Packagings and Packages § 178.608 Vibration standard. (a) Each packaging must be capable of withstanding, without rupture or leakage, the vibration test procedure outlined in this section. (b) Test method. (1...
49 CFR 178.608 - Vibration standard.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 3 2014-10-01 2014-10-01 false Vibration standard. 178.608 Section 178.608... Packagings and Packages § 178.608 Vibration standard. (a) Each packaging must be capable of withstanding, without rupture or leakage, the vibration test procedure outlined in this section. (b) Test method. (1...
49 CFR 178.608 - Vibration standard.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 3 2012-10-01 2012-10-01 false Vibration standard. 178.608 Section 178.608... Packagings and Packages § 178.608 Vibration standard. (a) Each packaging must be capable of withstanding, without rupture or leakage, the vibration test procedure outlined in this section. (b) Test method. (1...
NASA Technical Reports Server (NTRS)
Perkins, K. L.; Licari, J. J.
1978-01-01
The susceptibility of adhesive-sealed ceramic packages to moisture permeation was investigated. The two adhesives, Ablebond 789-1 and Epo-Tek H77, were evaluated as package sealants. These adhesives were previously selected as the most promising candidates for this application from a group of ten adhesives. Ceramic packages sealed with these adhesives were exposed to temperature-humidity conditions of 25 C/98 percent RH, 50 C/60 percent RH, 50 C/98 percent RH, and 85 C/85 percent RH and their moisture contents using were monitored solid state moisture sensors sealed inside them. Five packages were tested at each of these exposures - two ceramic packages sealed with each of the two adhesives and one seam-sealed gold-plated Kovar package. This latter package was included to serve as a control. The results showed that the adhesive-sealed packages were not hermetic to moisture. The rates at which moisture entered the packages increased with the severity of the exposure environments (i.e., higher temperatures and higher moisture vapor pressures) with greater dependence on temperature than on moisture vapor pressure.
Pinto, Vinícius Rodrigues Arruda; Freitas, Tamara Beatriz de Oliveira; Dantas, Maria Inês de Souza; Della Lucia, Suzana Maria; Melo, Laura Fernandes; Minim, Valéria Paula Rodrigues; Bressan, Josefina
2017-11-01
Concerns for health can lead to healthier food choices, especially if the consumer is well informed. This study aimed to evaluate the importance of package and health-related claims on Brazilian consumers' acceptance of snack bars. In order to evaluate package attributes, in focus groups discussions, 19 consumers chose the most important factors that influence their purchase decisions. Next, 102 consumers evaluated six commercial brands of snack bars in a three-session acceptance test: the first with no information about the product, the second containing the product package and the third with information on health-related claims associated with consumption of the bar. In general, package attributes, price and flavor were the most important factors that influence the purchase of snack bars. Health claims positively influenced consumer acceptance, but information concerning the absence of gluten and lactose did not significantly alter sensory acceptance. The presence of omega-3s, sugars, preservatives, flavorings and colorings have the potential to improve acceptability, because they were able to raise the acceptance of the seed bar, removing it from the rejection region. Protein and nut bars are not well known to the general public and the lower mean acceptance of the seed and protein bars demonstrated the need for sensorial improvement. Copyright © 2017 Elsevier Ltd. All rights reserved.
Stability Study of Sunscreens with Free and Encapsulated UV Filters Contained in Plastic Packaging
Briasco, Benedetta; Capra, Priscilla; Mannucci, Barbara; Perugini, Paola
2017-01-01
Sunscreens play a fundamental role in skin cancer prevention and in protection against photo-aging. UV filters are often photo-unstable, especially in relation to their vehicles and, being lipophilic substances, they are able to interact with plastic packaging. Finally, UV filter stability can be significantly affected by the routine use of the product at high temperatures. This work aims to study the stability of sunscreen formulations in polyethylene packaging. Butyl methoxydibenzoylmethane and octocrylene, both in a free form and as encapsulated filters were chosen as UV filters. Stability evaluations were performed both in the packaging and on the formulations. Moreover, a further two non-destructive techniques, near-infrared (NIR) spectroscopy and a multiple light scattering technique, were also used to evaluate the stability of the formulation. Results demonstrated clearly that all of the pack underwent significant changes in its elastic/plastic behavior and in external color after solar irradiation. From the evaluation of the extractable profile of untreated and treated packaging material an absorption of 2-phenoxyethanol and octocrylene were shown. In conclusion, the results highlighted clearly that a reduction of the UV filter in the formulation packed in high-density polyethylene/low-density polyethylene (HDPE/LDPE) material can occur over time, reducing the protective effect of the product when applied to the skin. PMID:28561775
Stability Study of Sunscreens with Free and Encapsulated UV Filters Contained in Plastic Packaging.
Briasco, Benedetta; Capra, Priscilla; Mannucci, Barbara; Perugini, Paola
2017-05-31
Sunscreens play a fundamental role in skin cancer prevention and in protection against photo-aging. UV filters are often photo-unstable, especially in relation to their vehicles and, being lipophilic substances, they are able to interact with plastic packaging. Finally, UV filter stability can be significantly affected by the routine use of the product at high temperatures. This work aims to study the stability of sunscreen formulations in polyethylene packaging. Butyl methoxydibenzoylmethane and octocrylene, both in a free form and as encapsulated filters were chosen as UV filters. Stability evaluations were performed both in the packaging and on the formulations. Moreover, a further two non-destructive techniques, near-infrared (NIR) spectroscopy and a multiple light scattering technique, were also used to evaluate the stability of the formulation. Results demonstrated clearly that all of the pack underwent significant changes in its elastic/plastic behavior and in external color after solar irradiation. From the evaluation of the extractable profile of untreated and treated packaging material an absorption of 2-phenoxyethanol and octocrylene were shown. In conclusion, the results highlighted clearly that a reduction of the UV filter in the formulation packed in high-density polyethylene/low-density polyethylene (HDPE/LDPE) material can occur over time, reducing the protective effect of the product when applied to the skin.
Eddylicious: A Python package for turbulent inflow generation
NASA Astrophysics Data System (ADS)
Mukha, Timofey; Liefvendahl, Mattias
2018-01-01
A Python package for generating inflow for scale-resolving computer simulations of turbulent flow is presented. The purpose of the package is to unite existing inflow generation methods in a single code-base and make them accessible to users of various Computational Fluid Dynamics (CFD) solvers. The currently existing functionality consists of an accurate inflow generation method suitable for flows with a turbulent boundary layer inflow and input/output routines for coupling with the open-source CFD solver OpenFOAM.
A Comparative Study of Inspection Techniques for Array Packages
NASA Technical Reports Server (NTRS)
Mohammed, Jelila; Green, Christopher
2008-01-01
This viewgraph presentation reviews the inspection techniques for Column Grid Array (CGA) packages. The CGA is a method of chip scale packaging using high temperature solder columns to attach part to board. It is becoming more popular over other techniques (i.e. quad flat pack (QFP) or ball grid array (BGA)). However there are environmental stresses and workmanship challenges that require good inspection techniques for these packages.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kapoor, A.; Gordon, S.; Goldston, W.
2013-07-08
This paper describes the operating experience and lessons learned at U.S. Department of Energy (DOE) sites as a result of an evaluation of potential trailer contamination and soft-sided packaging integrity issues related to the disposal of low-level and mixed low-level (LLW/MLLW) radioactive waste shipments. Nearly 4.3 million cubic meters of LLW/MLLW will have been generated and disposed of during fiscal year (FY) 2010 to FY 2015—either at commercial disposal sites or disposal sites owned by DOE. The LLW/MLLW is packaged in several different types of regulatory compliant packaging and transported via highway or rail to disposal sites safely and efficientlymore » in accordance with federal, state, and local regulations and DOE orders. In 1999, DOE supported the development of LLW containers that are more volumetrically efficient, more cost effective, and easier to use as compared to metal or wooden containers that existed at that time. The DOE Idaho National Engineering and Environmental Laboratory (INEEL), working in conjunction with the plastic industry, tested several types of soft-sided waste packaging systems that meet U.S. Department of Transportation requirements for transport of low specific activity and surface contaminated objects. Since then, soft-sided packaging of various capacities have been used successfully by the decontamination and decommissioning (D&D) projects to package, transport, and dispose D&D wastes throughout the DOE complex. The joint team of experts assembled by the Energy Facility Contractors Group from DOE waste generating sites, DOE and commercial waste disposal facilities, and soft-sided packaging suppliers conducted the review of soft-sided packaging operations and transportation of these packages to the disposal sites. As a result of this evaluation, the team developed several recommendations and best practices to prevent or minimize the recurrences of equipment contamination issues and proper use of soft-sided packaging for transport and disposal of waste.« less
Jo, Catherine L; Ambs, Anita; Dresler, Carolyn M; Backinger, Cathy L
2017-02-01
We aimed to investigate the effects of special packaging (child-resistant, adult-friendly) and tamper-resistant packaging on health and behavioral outcomes in order to identify research gaps and implications for packaging standards for tobacco products. We searched seven databases for keywords related to special and tamper-resistant packaging, consulted experts, and reviewed citations of potentially relevant studies. 733 unique papers were identified. Two coders independently screened each title and abstract for eligibility. They then reviewed the full text of the remaining papers for a second round of eligibility screening. Included studies investigated a causal relationship between type of packaging or packaging regulation and behavioral or health outcomes and had a study population composed of consumers. Studies were excluded on the basis of publication type, if they were not peer-reviewed, and if they had low external validity. Two reviewers independently coded each paper for study and methodological characteristics and limitations. Discrepancies were discussed and resolved. The review included eight studies: four assessing people's ability to access the contents of different packaging types and four evaluating the impact of packaging requirements on health-related outcomes. Child-resistant packaging was generally more difficult to open than non-child-resistant packaging. Child-resistant packaging requirements have been associated with reductions in child mortality. Child-resistant packaging holds the expectation to reduce tobacco product poisonings among children under six. Published by Elsevier Inc.
diffHic: a Bioconductor package to detect differential genomic interactions in Hi-C data.
Lun, Aaron T L; Smyth, Gordon K
2015-08-19
Chromatin conformation capture with high-throughput sequencing (Hi-C) is a technique that measures the in vivo intensity of interactions between all pairs of loci in the genome. Most conventional analyses of Hi-C data focus on the detection of statistically significant interactions. However, an alternative strategy involves identifying significant changes in the interaction intensity (i.e., differential interactions) between two or more biological conditions. This is more statistically rigorous and may provide more biologically relevant results. Here, we present the diffHic software package for the detection of differential interactions from Hi-C data. diffHic provides methods for read pair alignment and processing, counting into bin pairs, filtering out low-abundance events and normalization of trended or CNV-driven biases. It uses the statistical framework of the edgeR package to model biological variability and to test for significant differences between conditions. Several options for the visualization of results are also included. The use of diffHic is demonstrated with real Hi-C data sets. Performance against existing methods is also evaluated with simulated data. On real data, diffHic is able to successfully detect interactions with significant differences in intensity between biological conditions. It also compares favourably to existing software tools on simulated data sets. These results suggest that diffHic is a viable approach for differential analyses of Hi-C data.
Karas, Panagiotis A; Perruchon, Chiara; Karanasios, Evangelos; Papadopoulou, Evangelia S; Manthou, Elena; Sitra, Stefania; Ehaliotis, Constantinos; Karpouzas, Dimitrios G
2016-12-15
Wastewaters from fruit-packaging plants contain high loads of toxic and persistent pesticides and should be treated on site. We evaluated the depuration performance of five pilot biobeds against those effluents. In addition we tested bioaugmentation with bacterial inocula as a strategy for optimization of their depuration capacity. Finally we determined the composition and functional dynamics of the microbial community via q-PCR. Practical issues were also addressed including the risk associated with the direct environmental disposal of biobed-treated effluents and decontamination methods for the spent packing material. Biobeds showed high depuration capacity (>99.5%) against all pesticides with bioaugmentation maximizing their depuration performance against the persistent fungicide thiabendazole (TBZ). This was followed by a significant increase in the abundance of bacteria, fungi and of catabolic genes of aromatic compounds catA and pcaH. Bioaugmentation was the most potent decontamination method for spent packing material with composting being an effective alternative. Risk assessment based on practical scenarios (pome and citrus fruit-packaging plants) and the depuration performance of the pilot biobeds showed that discharge of the treated effluents into an 0.1-ha disposal site did not entail an environmental risk, except for TBZ-containing effluents where a larger disposal area (0.2ha) or bioaugmentation alleviated the risk. Copyright © 2016 Elsevier B.V. All rights reserved.
Safety evaluation for packaging (onsite) plutonium recycle test reactor graphite cask
DOE Office of Scientific and Technical Information (OSTI.GOV)
Romano, T.
This safety evaluation for packaging (SEP) provides the evaluation necessary to demonstrate that the Plutonium Recycle Test Reactor (PRTR) Graphite Cask meets the requirements of WHC-CM-2-14, Hazardous Material Packaging and Shipping, for transfer of Type B, fissile, non-highway route controlled quantities of radioactive material within the 300 Area of the Hanford Site. The scope of this SEP includes risk, shieldling, criticality, and.tiedown analyses to demonstrate that onsite transportation safety requirements are satisfied. This SEP also establishes operational and maintenance guidelines to ensure that transport of the PRTR Graphite Cask is performed safely in accordance with WHC-CM-2-14. This SEP is validmore » until October 1, 1999. After this date, an update or upgrade to this document is required.« less
Path selection system simulation and evaluation for a Martian roving vehicle
NASA Technical Reports Server (NTRS)
Boheim, S. L.; Prudon, W. C.
1972-01-01
The simulation and evaluation of proposed path selection systems for an autonomous Martian roving vehicle was developed. The package incorporates a number of realistic features, such as the simulation of random effects due to vehicle bounce and sensor-reading uncertainty, to increase the reliability of the results. Qualitative and quantitative evaluation criteria were established. The performance of three different path selection systems was evaluated to determine the effectiveness of the simulation package, and to form some preliminary conclusions regarding the tradeoffs involved in a path selection system design.
NASA Astrophysics Data System (ADS)
Parra, Duclerc F.; Rodrigues, Juliana A. F. R.; Lugão, Ademar B.
2005-07-01
Gamma irradiation is an alternative method for the manufacture of sterilized packaging with increased storage stability and microbiological safety. Biopolymer-based packaging films are a potential solution to many environmental problems that have emerged from the production and accumulation of significant amounts of synthetic polymeric waste. This work was undertaken to verify the effectiveness of low-dose gamma-irradiation in obtaining biopolymer-based packaging films for shelf-stable foods. PHB polyester poly(3-hydroxybutyrate) is an interesting biodegradable polymer that has been intensely investigated as cast and sheet films, with applications in the food industry and medicine. The films obtained are, however, typically brittle, and many scientists have attempted to reduce this brittleness by blending PHB with other polymers. In the present work, PHB was blended with PEG (polyethyleneglycol) to obtain films by the casting method that were then irradiated at a dose rate of 5.72 kGy/h with a 60Co source. Samples were melted at 200 °C and quenched to 0 °C in order to evaluate film crystallinity levels by differential scanning calorimetry (DSC). DSC analyses were performed with the samples (10 mg) under N2 atmosphere, heating from -50 to 200 °C (10 °C min-1), cooling from 200 to -50 °C (10 °C min-1); and heating from -50 to 200 °C (10 °C min-1). The thermal and mechanical resistances of the films after irradiation at low doses (5, 10, 20 kGy) are discussed. Water vapour transmission decreased with increasing irradiation dose, indicating that the films' performance as water vapour barrier had improved. Critical loss of the mechanical properties was observed at 40 kGy.
Droulers, Olivier; Lacoste-Badie, Sophie; Lajante, Mathieu
2017-01-01
The first aim of this research was to assess the effectiveness, in terms of emotional and behavioral reactions, of moderately vs. highly TVWs (Threatening Visual Warnings) displayed on tobacco packs. Given the key role that emotional reactions play in explaining the effect of TVWs on behaviors, psychophysiological and self-report methods were used–for the first time in this context–to measure the emotions provoked by TVWs. The second aim of this research was to determine whether increasing the size of warnings, and their display on plain packaging (compared with branded packaging) would improve their effectiveness. A within-subjects experiment was conducted. Three variables were manipulated: health warning threat level (high vs. moderate), image size (40% vs. 75%) and pack type (plain vs. branded). A convenience sample of 48 French daily smokers participated. They were exposed to eight different packs of cigarettes in a research lab at the University of Rennes. Smokers’ emotions and behavioral intentions were recorded through self-reports. Emotions were also evaluated using psychophysiological measurements: electrodermal activity and facial electromyography. The results revealed that TVWs with a high threat level are the most effective in increasing negative emotions (fear, disgust, valence, arousal) and behavioral intentions conducive to public health (desire to quit, etc.). They also highlight the appeal of increasing the size of the warnings and displaying them on plain packs, because this influences emotions, which is the first step toward behavioral change. Increasing the threat level of TVWs from moderate to high seems beneficial for public health. Our results also confirm the relevance of recent governmental decisions to adopt plain packaging and larger TVWs (in the UK, France, Ireland, Canada, New Zealand, Hungary, etc.). PMID:28910317
Highly-optimized TWSM software package for seismic diffraction modeling adapted for GPU-cluster
NASA Astrophysics Data System (ADS)
Zyatkov, Nikolay; Ayzenberg, Alena; Aizenberg, Arkady
2015-04-01
Oil producing companies concern to increase resolution capability of seismic data for complex oil-and-gas bearing deposits connected with salt domes, basalt traps, reefs, lenses, etc. Known methods of seismic wave theory define shape of hydrocarbon accumulation with nonsufficient resolution, since they do not account for multiple diffractions explicitly. We elaborate alternative seismic wave theory in terms of operators of propagation in layers and reflection-transmission at curved interfaces. Approximation of this theory is realized in the seismic frequency range as the Tip-Wave Superposition Method (TWSM). TWSM based on the operator theory allows to evaluate of wavefield in bounded domains/layers with geometrical shadow zones (in nature it can be: salt domes, basalt traps, reefs, lenses, etc.) accounting for so-called cascade diffraction. Cascade diffraction includes edge waves from sharp edges, creeping waves near concave parts of interfaces, waves of the whispering galleries near convex parts of interfaces, etc. The basic algorithm of TWSM package is based on multiplication of large-size matrices (make hundreds of terabytes in size). We use advanced information technologies for effective realization of numerical procedures of the TWSM. In particular, we actively use NVIDIA CUDA technology and GPU accelerators allowing to significantly improve the performance of the TWSM software package, that is important in using it for direct and inverse problems. The accuracy, stability and efficiency of the algorithm are justified by numerical examples with curved interfaces. TWSM package and its separate components can be used in different modeling tasks such as planning of acquisition systems, physical interpretation of laboratory modeling, modeling of individual waves of different types and in some inverse tasks such as imaging in case of laterally inhomogeneous overburden, AVO inversion.
Droulers, Olivier; Gallopel-Morvan, Karine; Lacoste-Badie, Sophie; Lajante, Mathieu
2017-01-01
The first aim of this research was to assess the effectiveness, in terms of emotional and behavioral reactions, of moderately vs. highly TVWs (Threatening Visual Warnings) displayed on tobacco packs. Given the key role that emotional reactions play in explaining the effect of TVWs on behaviors, psychophysiological and self-report methods were used-for the first time in this context-to measure the emotions provoked by TVWs. The second aim of this research was to determine whether increasing the size of warnings, and their display on plain packaging (compared with branded packaging) would improve their effectiveness. A within-subjects experiment was conducted. Three variables were manipulated: health warning threat level (high vs. moderate), image size (40% vs. 75%) and pack type (plain vs. branded). A convenience sample of 48 French daily smokers participated. They were exposed to eight different packs of cigarettes in a research lab at the University of Rennes. Smokers' emotions and behavioral intentions were recorded through self-reports. Emotions were also evaluated using psychophysiological measurements: electrodermal activity and facial electromyography. The results revealed that TVWs with a high threat level are the most effective in increasing negative emotions (fear, disgust, valence, arousal) and behavioral intentions conducive to public health (desire to quit, etc.). They also highlight the appeal of increasing the size of the warnings and displaying them on plain packs, because this influences emotions, which is the first step toward behavioral change. Increasing the threat level of TVWs from moderate to high seems beneficial for public health. Our results also confirm the relevance of recent governmental decisions to adopt plain packaging and larger TVWs (in the UK, France, Ireland, Canada, New Zealand, Hungary, etc.).
Li, Liang; Diederick, Ryan; Flora, Joseph R V; Berge, Nicole D
2013-11-01
Hydrothermal carbonization (HTC) is a thermal conversion technique that converts food wastes and associated packaging materials to a valuable, energy-rich resource. Food waste collected from local restaurants was carbonized over time at different temperatures (225, 250 and 275°C) and solids concentrations to determine how process conditions influence carbonization product properties and composition. Experiments were also conducted to determine the influence of packaging material on food waste carbonization. Results indicate the majority of initial carbon remains integrated within the solid-phase at the solids concentrations and reaction temperatures evaluated. Initial solids concentration influences carbon distribution because of increased compound solubilization, while changes in reaction temperature imparted little change on carbon distribution. The presence of packaging materials significantly influences the energy content of the recovered solids. As the proportion of packaging materials increase, the energy content of recovered solids decreases because of the low energetic retention associated with the packaging materials. HTC results in net positive energy balances at all conditions, except at a 5% (dry wt.) solids concentration. Carbonization of food waste and associated packaging materials also results in net positive balances, but energy needs for solids post-processing are significant. Advantages associated with carbonization are not fully realized when only evaluating process energetics. A more detailed life cycle assessment is needed for a more complete comparison of processes. Copyright © 2013 Elsevier Ltd. All rights reserved.
Flexible Packaging by Film-Assisted Molding for Microintegration of Inertia Sensors
Hera, Daniel; Berndt, Armin; Günther, Thomas; Schmiel, Stephan; Harendt, Christine; Zimmermann, André
2017-01-01
Packaging represents an important part in the microintegration of sensors based on microelectromechanical system (MEMS). Besides miniaturization and integration density, functionality and reliability in combination with flexibility in packaging design at moderate costs and consequently high-mix, low-volume production are the main requirements for future solutions in packaging. This study investigates possibilities employing printed circuit board (PCB-)based assemblies to provide high flexibility for circuit designs together with film-assisted transfer molding (FAM) to package sensors. The feasibility of FAM in combination with PCB and MEMS as a packaging technology for highly sensitive inertia sensors is being demonstrated. The results prove the technology to be a viable method for damage-free packaging of stress- and pressure-sensitive MEMS. PMID:28653992
Del Carratore, Francesco; Jankevics, Andris; Eisinga, Rob; Heskes, Tom; Hong, Fangxin; Breitling, Rainer
2017-09-01
The Rank Product (RP) is a statistical technique widely used to detect differentially expressed features in molecular profiling experiments such as transcriptomics, metabolomics and proteomics studies. An implementation of the RP and the closely related Rank Sum (RS) statistics has been available in the RankProd Bioconductor package for several years. However, several recent advances in the understanding of the statistical foundations of the method have made a complete refactoring of the existing package desirable. We implemented a completely refactored version of the RankProd package, which provides a more principled implementation of the statistics for unpaired datasets. Moreover, the permutation-based P -value estimation methods have been replaced by exact methods, providing faster and more accurate results. RankProd 2.0 is available at Bioconductor ( https://www.bioconductor.org/packages/devel/bioc/html/RankProd.html ) and as part of the mzMatch pipeline ( http://www.mzmatch.sourceforge.net ). rainer.breitling@manchester.ac.uk. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.
Getting started with package sampSurf
Jeffrey H. Gove
2014-01-01
The sampSurf package is designed to facilitate the comparison of new and existing areal sampling methods through simulation. The package is thoroughly documented in several vignettes as mentioned below. This document is meant to point you in the right direction in finding the needed information to get started using sampSurf.
49 CFR 178.970 - Bottom lift test.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Large Packagings design types designed to be lifted from the base, there may be no permanent deformation which renders the Large Packaging unsafe for transport and there must be no loss of contents. ... permissible gross mass, the load being evenly distributed. (c) Test method. All Large Packaging design types...
49 CFR 178.975 - Top lift test.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the test. For all Large Packagings design types designed to be lifted from the top, there may be no permanent deformation which renders the Large Packagings unsafe for transport and no loss of contents. ... load being evenly distributed. (c) Test method. (1) A Large Packaging must be lifted in the manner for...
49 CFR 178.970 - Bottom lift test.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Packagings design types designed to be lifted from the base, there may be no permanent deformation which renders the Large Packaging unsafe for transport and there must be no loss of contents. ... gross mass, the load being evenly distributed. (c) Test method. All Large Packaging design types must be...
49 CFR 178.970 - Bottom lift test.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Packagings design types designed to be lifted from the base, there may be no permanent deformation which renders the Large Packaging unsafe for transport and there must be no loss of contents. ... gross mass, the load being evenly distributed. (c) Test method. All Large Packaging design types must be...
49 CFR 178.970 - Bottom lift test.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Packagings design types designed to be lifted from the base, there may be no permanent deformation which renders the Large Packaging unsafe for transport and there must be no loss of contents. ... gross mass, the load being evenly distributed. (c) Test method. All Large Packaging design types must be...
49 CFR 178.970 - Bottom lift test.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Packagings design types designed to be lifted from the base, there may be no permanent deformation which renders the Large Packaging unsafe for transport and there must be no loss of contents. ... gross mass, the load being evenly distributed. (c) Test method. All Large Packaging design types must be...
49 CFR 178.985 - Vibration test.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 3 2013-10-01 2013-10-01 false Vibration test. 178.985 Section 178.985... Packagings § 178.985 Vibration test. (a) General. All rigid Large Packaging and flexible Large Packaging design types must be capable of withstanding the vibration test. (b) Test method. (1) A sample Large...
49 CFR 173.3 - Packaging and exceptions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... for transportation by air, highway, rail, or water must be as specified in this part. Methods of.... Packages of hazardous materials that are damaged, defective, or leaking; packages found to be not.... (ii) Must have a maximum water capacity of 450 L (119 gallons). (iii) Except for liquefied nitrous...
49 CFR 178.985 - Vibration test.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 3 2014-10-01 2014-10-01 false Vibration test. 178.985 Section 178.985... Packagings § 178.985 Vibration test. (a) General. All rigid Large Packaging and flexible Large Packaging design types must be capable of withstanding the vibration test. (b) Test method. (1) A sample Large...
49 CFR 178.985 - Vibration test.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 3 2012-10-01 2012-10-01 false Vibration test. 178.985 Section 178.985... Packagings § 178.985 Vibration test. (a) General. All rigid Large Packaging and flexible Large Packaging design types must be capable of withstanding the vibration test. (b) Test method. (1) A sample Large...
49 CFR 178.985 - Vibration test.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 2 2010-10-01 2010-10-01 false Vibration test. 178.985 Section 178.985... Testing of Large Packagings § 178.985 Vibration test. (a) General. All rigid Large Packaging and flexible Large Packaging design types must be capable of withstanding the vibration test. (b) Test method. (1) A...
49 CFR 178.985 - Vibration test.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 3 2011-10-01 2011-10-01 false Vibration test. 178.985 Section 178.985... Packagings § 178.985 Vibration test. (a) General. All rigid Large Packaging and flexible Large Packaging design types must be capable of withstanding the vibration test. (b) Test method. (1) A sample Large...
LANZ: Software solving the large sparse symmetric generalized eigenproblem
NASA Technical Reports Server (NTRS)
Jones, Mark T.; Patrick, Merrell L.
1990-01-01
A package, LANZ, for solving the large symmetric generalized eigenproblem is described. The package was tested on four different architectures: Convex 200, CRAY Y-MP, Sun-3, and Sun-4. The package uses a Lanczos' method and is based on recent research into solving the generalized eigenproblem.
40 CFR 300.425 - Establishing remedial priorities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... may submit HRS scoring packages to EPA anytime throughout the year. (2) EPA shall review lead agencies' HRS scoring packages and revise them as appropriate. EPA shall develop any additional HRS scoring packages on releases known to EPA. (3) EPA shall compile the NPL based on the methods identified in...
40 CFR 300.425 - Establishing remedial priorities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... may submit HRS scoring packages to EPA anytime throughout the year. (2) EPA shall review lead agencies' HRS scoring packages and revise them as appropriate. EPA shall develop any additional HRS scoring packages on releases known to EPA. (3) EPA shall compile the NPL based on the methods identified in...
40 CFR 300.425 - Establishing remedial priorities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... may submit HRS scoring packages to EPA anytime throughout the year. (2) EPA shall review lead agencies' HRS scoring packages and revise them as appropriate. EPA shall develop any additional HRS scoring packages on releases known to EPA. (3) EPA shall compile the NPL based on the methods identified in...
40 CFR 300.425 - Establishing remedial priorities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... may submit HRS scoring packages to EPA anytime throughout the year. (2) EPA shall review lead agencies' HRS scoring packages and revise them as appropriate. EPA shall develop any additional HRS scoring packages on releases known to EPA. (3) EPA shall compile the NPL based on the methods identified in...
40 CFR 300.425 - Establishing remedial priorities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... may submit HRS scoring packages to EPA anytime throughout the year. (2) EPA shall review lead agencies' HRS scoring packages and revise them as appropriate. EPA shall develop any additional HRS scoring packages on releases known to EPA. (3) EPA shall compile the NPL based on the methods identified in...
NDE Software Developed at NASA Glenn Research Center
NASA Technical Reports Server (NTRS)
Roth, Donald J.; Martin, Richard E.; Rauser, Richard W.; Nichols, Charles; Bonacuse, Peter J.
2014-01-01
NASA Glenn Research Center has developed several important Nondestructive Evaluation (NDE) related software packages for different projects in the last 10 years. Three of the software packages have been created with commercial-grade user interfaces and are available to United States entities for download on the NASA Technology Transfer and Partnership Office server (https://sr.grc.nasa.gov/). This article provides brief overviews of the software packages.
Packaging food for radiation processing
NASA Astrophysics Data System (ADS)
Komolprasert, Vanee
2016-12-01
Irradiation can play an important role in reducing pathogens that cause food borne illness. Food processors and food safety experts prefer that food be irradiated after packaging to prevent post-irradiation contamination. Food irradiation has been studied for the last century. However, the implementation of irradiation on prepackaged food still faces challenges on how to assess the suitability and safety of these packaging materials used during irradiation. Irradiation is known to induce chemical changes to the food packaging materials resulting in the formation of breakdown products, so called radiolysis products (RP), which may migrate into foods and affect the safety of the irradiated foods. Therefore, the safety of the food packaging material (both polymers and adjuvants) must be determined to ensure safety of irradiated packaged food. Evaluating the safety of food packaging materials presents technical challenges because of the range of possible chemicals generated by ionizing radiation. These challenges and the U.S. regulations on food irradiation are discussed in this article.
Retail lighting and packaging influence consumer acceptance of fluid milk.
Potts, H L; Amin, K N; Duncan, S E
2017-01-01
Little is known about the effect of retail light-emitting diode (LED) exposure on consumer acceptance of milk. The study objective was to determine effects of fluorescent and LED lighting under retail storage conditions on consumer acceptance of milk. Consumer acceptance of milk stored under retail conditions was determined through sensory evaluation (2 studies; n=150+ each) and analytical measures (dissolved oxygen, secondary oxidation products, riboflavin retention). Study 1 evaluated milk stored in high-density polyethylene (HDPE) packages for 4h under LED light (960 lx). Commercially available HDPE package treatments included translucent HDPE (most commonly used), white HDPE [low concentration (1.3%) TiO 2 ], and yellow HDPE; in addition, HDPE with a higher TiO 2 concentration (high white; 4.9% TiO 2 ) and a foil-wrapped translucent HDPE (control) were tested. Translucent and control packages also were tested under fluorescent light. Study 2 evaluated polyethylene terephthalate (PET) packages for 4h under fluorescent and LED light (1,460 lx). The PET packaging included 2 treatments (medium, 4.0% TiO 2 ; high, 6.6% TiO 2 ) as well as translucent HDPE (exposed to fluorescent), clear PET (fluorescent and LED), and light-protected control. Overall mean acceptability of milk ranged from "like slightly" to "like moderately" with significantly lower acceptability for milk exposed to fluorescent light. Milk in HDPE and PET packages had comparable overall acceptability scores when exposed to LED light. Only the fluorescent light condition (both PET and HDPE) diminished overall acceptability. Fluorescent light exposure negatively influenced flavor with significant penalty (2.0-2.5 integers) to overall acceptability of milk in translucent HDPE and clear PET. The LED also diminished aftertaste of milk packaged in translucent HDPE. Changes in dissolved oxygen content, as an indication of oxidation, supported the observed differences in consumer acceptance of milk stored under fluorescent and LED light. Consumers like the flavor of fresh milk, which can be protected by selecting appropriate packaging that blocks detrimental light wavelengths. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Queiroz, Sabrina Ribeiro de Almeida; Silva Júnior, José Valter Joaquim; Silva, Andréa Nazaré Monteiro Rangel da; Carvalho, Amanda Gomes de Oliveira; Santos, Jefferson José da Silva; Gil, Laura Helena Vega Gonzales
2018-01-01
Pseudo-infectious yellow fever viral particles (YFV-PIVs) have been used to study vaccines and viral packaging. Here, we report the development of a packaging cell line, which expresses the YFV prM/E proteins. HEK293 cells were transfected with YFV prM/E and C (84 nt) genes to generate HEK293-YFV-PrM/E-opt. The cells were evaluated for their ability to express the heterologous proteins and to package the replicon repYFV-17D-LucIRES, generating YFV-PIVs. The expression of prM/E proteins was confirmed, and the cell line trans-packaged the replicon for recovery of a reporter for the YFV-PIVs. HEK293-YFV-prM/E-opt trans-packaging capacity demonstrates its possible biotechnology application.
Zhu, J; Huang, H Y; Mao, A Y; Sun, Z X; Qiu, W Q; Lei, H K; Dong, P; Huang, J W; Bai, Y N; Sun, X J; Liu, G X; Wang, D B; Liao, X Z; Ren, J S; Guo, L W; Lan, L; Zhou, Q; Song, B B; Liu, Y Q; Du, L B; Zhu, L; Cao, R; Wang, J L; Mai, L; Ren, Y; Zhou, J Y; Sun, X H; Wu, S L; Qi, X; Lou, P A; Cai, B; Li, N; Zhang, K; He, J; Dai, M; Shi, J F
2018-02-10
Objective: From an actual cancer screening service demanders' perspective, we tried to understand the preference on screening frequency and willingness-to-pay for the packaging screening program on common cancers and to evaluate its long-term sustainability in urban populations in China. Methods: From 2012 to 2014, a multi-center cross-sectional survey was conducted among the actual screening participants from 13 provinces covered by the Cancer Screening Program in Urban China (CanSPUC). By face-to-face interview, information regarding to preference to screening frequency, willingness-to-pay for packaging screening program, maximum amount on payment and related reasons for unwillingness were investigated. Results: A total of 31 029 participants were included in this survey, with an average age as (55.2±7.5) years and median annual income per family as 25 000 Chinese Yuan. People's preference to screening frequency varied under different assumptions ( " totally free" and "self-paid" ). When the packaging screening was assumed totally free, 93.9% of residents would prefer to take the screening program every 1 to 3 years. However, the corresponding proportion dropped to 67.3% when assuming a self-paid pattern. 76.7% of the participants had the willingness-to-pay for the packaging screening, but only 11.2% of them would like to pay more than 500 Chinese Yuan (the expenditure of the particular packaging screening were about 1 500 Chinese Yuan). The remaining 23.3% of residents showed no willingness-to-pay, and the main reasons were unaffordable expenditure (71.7%) and feeling'no need'(40.4%). Conclusions: People who participated in the CanSPUC program generally tended to choose high-frequency packaging screening program, indicating the high potential acceptance for scale-up packaging screening, while it needs cautious assessments and rational guidance to the public. Although about seven in ten of the residents were willing to pay, the payment amount was limited, revealing the necessity of strengthening individual's awareness of his or her key role in health self-management, and a reasonable payment proportion should be considered when establishing co-compensation mechanism.
Steyn, Rachelle; Boniaszczuk, John; Geldenhuys, Theodore
2014-01-01
To determine how two software packages, supplied by Siemens and Hermes, for processing gated blood pool (GBP) studies should be used in our department and whether the use of different cameras for the acquisition of raw data influences the results. The study had two components. For the first component, 200 studies were acquired on a General Electric (GE) camera and processed three times by three operators using the Siemens and Hermes software packages. For the second part, 200 studies were acquired on two different cameras (GE and Siemens). The matched pairs of raw data were processed by one operator using the Siemens and Hermes software packages. The Siemens method consistently gave estimates that were 4.3% higher than the Hermes method (p < 0.001). The differences were not associated with any particular level of left ventricular ejection fraction (LVEF). There was no difference in the estimates of LVEF obtained by the three operators (p = 0.1794). The reproducibility of estimates was good. In 95% of patients, using the Siemens method, the SD of the three estimates of LVEF by operator 1 was ≤ 1.7, operator 2 was ≤ 2.1 and operator 3 was ≤ 1.3. The corresponding values for the Hermes method were ≤ 2.5, ≤ 2.0 and ≤ 2.1. There was no difference in the results of matched pairs of data acquired on different cameras (p = 0.4933) CONCLUSION: Software packages for processing GBP studies are not interchangeable. The report should include the name and version of the software package used. Wherever possible, the same package should be used for serial studies. If this is not possible, the report should include the limits of agreement of the different packages. Data acquisition on different cameras did not influence the results.
Overall impact of speed-related initiatives and factors on crash outcomes.
D'Elia, A; Newstead, S; Cameron, M
2007-01-01
From December 2000 until July 2002 a package of speed-related initiatives and factors took place in Victoria, Australia. The broad aim of this study was to evaluate the overall impact of the package on crash outcomes. Monthly crash counts and injury severity proportions were assessed using Poisson and logistic regression models respectively. The model measured the overall effect of the package after adjusting as far as possible for non-speed road safety initiatives and socio-economic factors. The speed-related package was associated with statistically significant estimated reductions in casualty crashes and suggested reductions in injury severity with trends towards increased reductions over time. From December 2000 until July 2002, three new speed enforcement initiatives were implemented in Victoria, Australia. These initiatives were introduced in stages and involved the following key components: More covert operations of mobile speed cameras, including flash-less operations; 50% increase in speed camera operating hours; and lowering of cameras' speed detection threshold. In addition, during the period 2001 to 2002, the 50 km/h General Urban Speed Limit (GUSL) was introduced (January 2001), there was an increase in speed-related advertising including the "Wipe Off 5" campaign, media announcements were made related to the above enforcement initiatives and there was a speeding penalty restructure. The above elements combine to make up a package of speed-related initiatives and factors. The package represents a broad, long term program by Victorian government agencies to reduce speed based on three linked strategies: more intensive Police enforcement of speed limits to deter potential offenders, i.e. the three new speed enforcement initiatives just described - supported by higher penalties; a reduction in the speed limit on local streets throughout Victoria from 60 km/h to 50 km/h; and provision of information using the mass media (television, radio and billboard) to reinforce the benefits of reducing low level speeding - the central message of "Wipe Off 5". These strategies were implemented across the entire state of Victoria with the intention of covering as many road users as possible. This study aimed to evaluate the overall effectiveness of the speed-related package. The study objectives were: to document the increased speed camera activity in each speed limit zone and in Melbourne compared with the rest of Victoria; to evaluate the overall effect on crash outcomes of the package; to account as far as possible for the effect on crash outcomes of non-speed road safety initiatives and socio-economic factors, which would otherwise influence the speed-related package evaluation; and to examine speed trends in Melbourne and on Victorian rural highways, especially the proportions of vehicles travelling at excessive speeds. This paper presents the results of the evaluation of the overall impact on crash outcomes associated with the speed-related package, after adjusting as far as possible for the effect of non-speed road safety initiatives and socio-economic factors. D'Elia, Newstead and Cameron (2007) document the study results in full.
Young people's perceptions of cigarette packaging and plain packaging: an online survey.
Moodie, Crawford; Ford, Allison; Mackintosh, Anne Marie; Hastings, Gerard
2012-01-01
In the United Kingdom, with most marketing channels prohibited, packaging is one of the few remaining ways that tobacco companies can promote their products. An online survey with young people aged 10-17 years (N = 658) was used to explore why youth choose cigarettes, perceptions of pack color, and perceptions of plain (nonbranded) cigarette packaging. Young people were also shown an image of 3 plain packs, which differed by shape and method of opening, and asked which they liked most and thought others their age would smoke. Price and what significant others smoke were key factors for choosing cigarettes, with packaging also an important influence. More than a third of the sample associated lighter pack color with weak tasting and less harmful cigarettes. Plain packs were rated negatively as were perceptions of plain pack users. One in 3 showed a preference for either a narrow "perfume type" plain pack or a plain "slide" pack that opened from the side, and 1 in 3 also thought that young people would smoke these packs. Packaging appears to both attract young people and mislead them about product strength and relative harm. Innovative pack construction (novel pack shape and method of opening) and the use of color are instrumental in these effects. The findings therefore suggest that any move to plain packaging should not only consider the benefits of removing branding (including color) but also of standardizing pack construction in terms of shape and method of opening.
Development of low cost custom hybrid microcircuit technology
NASA Technical Reports Server (NTRS)
Perkins, K. L.; Licari, J. J.
1981-01-01
Selected potentially low cost, alternate packaging and interconnection techniques were developed and implemented in the manufacture of specific NASA/MSFC hardware, and the actual cost savings achieved by their use. The hardware chosen as the test bed for this evaluation ws the hybrids and modules manufactured by Rockwell International fo the MSFC Flight Accelerometer Safety Cut-Off System (FASCOS). Three potentially low cost packaging and interconnection alternates were selected for evaluation. This study was performed in three phases: hardware fabrication and testing, cost comparison, and reliability evaluation.
Multiple internal seal ring micro-electro-mechanical system vacuum packaging method
NASA Technical Reports Server (NTRS)
Hayworth, Ken J. (Inventor); Yee, Karl Y. (Inventor); Shcheglov, Kirill V. (Inventor); Bae, Youngsam (Inventor); Wiberg, Dean V. (Inventor); Challoner, A. Dorian (Inventor); Peay, Chris S. (Inventor)
2008-01-01
A Multiple Internal Seal Ring (MISR) Micro-Electro-Mechanical System (MEMS) vacuum packaging method that hermetically seals MEMS devices using MISR. The method bonds a capping plate having metal seal rings to a base plate having metal seal rings by wafer bonding the capping plate wafer to the base plate wafer. Bulk electrodes may be used to provide conductive paths between the seal rings on the base plate and the capping plate. All seals are made using only metal-to-metal seal rings deposited on the polished surfaces of the base plate and capping plate wafers. However, multiple electrical feed-through metal traces are provided by fabricating via holes through the capping plate for electrical connection from the outside of the package through the via-holes to the inside of the package. Each metal seal ring serves the dual purposes of hermetic sealing and providing the electrical feed-through metal trace.
Safety evaluation for packaging for the transport of K Basin sludge samples in the PAS-1 cask
DOE Office of Scientific and Technical Information (OSTI.GOV)
SMITH, R.J.
1998-11-17
This safety evaluation for packaging authorizes the shipment of up to two 4-L sludge samples to and from the 325 Lab or 222-S Lab for characterization. The safety of this shipment is based on the current U.S. Department of Energy Certification of Compliance (CoC) for the PAS-1 cask, USA/9184/B(U) (DOE).
User’s guide for GcClust—An R package for clustering of regional geochemical data
Ellefsen, Karl J.; Smith, David B.
2016-04-08
GcClust is a software package developed by the U.S. Geological Survey for statistical clustering of regional geochemical data, and similar data such as regional mineralogical data. Functions within the software package are written in the R statistical programming language. These functions, their documentation, and a copy of the user’s guide are bundled together in R’s unit of sharable code, which is called a “package.” The user’s guide includes step-by-step instructions showing how the functions are used to cluster data and to evaluate the clustering results. These functions are demonstrated in this report using test data, which are included in the package.
Morton, Paula J; Conner, Ramona
2014-04-01
The delivery of sterile products to the sterile field is essential to perioperative practice. The use of protective packaging for sterilized items is crucial to helping ensure that patients receive sterile items for surgical procedures. AORN's "Recommended practices for selection and use of packaging systems for sterilization" offers guidance to perioperative team members in evaluating, selecting, and using packaging systems that permit sterilization of the contents, prevent contamination of sterilized items until the package is opened for use, protect the items from damage during transport and storage, and permit aseptic delivery of the items to the sterile field. Copyright © 2014 AORN, Inc. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Craighead, F. C., Jr.
1978-01-01
Equipment development and testing, animal-instrument interphase or attachment methods, and the evaluation of various feasibility-tracking experiments with raptors are described as well as suggestions for expediting a future program. Results of animal-instrument interphases work indicate that large free-flying birds can be successfully instrumented with radio packages comparable in weight to satellite-transmitter packages. The 401 MHz frequency proved satisfactory for a combination of satellite and ground tracking of migrating birds. Tests run for nearly a year with the Nimbus 6 satellite and a miniaturized, one-watt prototype RAMS transmitter produced encouraging results in regard to location accuracy, frequency of contact with satellite and use of whip antennas. A future program is recommended with priority given to development of six operational transmitters for feasibility experiments.
Deus, D; Kehrenberg, C; Schaudien, D; Klein, G; Krischek, C
2017-02-01
Nano-silver is used in consumer products due to its antibacterial properties. The aim of this study was to evaluate the effect of a nano-silver-coated film on the quality of turkey meat during vacuum-sealed and modified atmosphere packaging up to 12 days of storage. In the first part of the experiment, turkey breasts were packaged using either vacuum packaging or modified atmosphere packages (MAPs) and contained films with or without a nano-silver coating (control film). Parameters such as pH, electrical conductivity, color (lightness L*, redness a*), myoglobin redox forms, thiobarbituric acid-reactive substances (TBARS), biogenic amines (BAs), total viable bacterial counts, Pseudomonas species counts, and Enterobacteriaceae species counts were evaluated on storage days 4, 8, and 12. In the second part of the study, the antimicrobial effect of a nano-silver-coated film on turkey breast was evaluated after inoculation with Escherichia coli (E. coli). Turkey meat packaged with the nano-silver film exhibited lower a* values on days 1 (3.15 ± 0.62), 4 (3.90 ± 0.68), and 8 (4.27 ± 0.76) compared to the packaged meat with the control film (3.41 ± 0.73, 4.35 ± 0.94, 4.85 ± 0.89, respectively), indicating special optical properties of nanoparticles. Concerning the BAs, silver packaged meat showed higher values of tyramine on day 12 (1274 ± 392 ng/g meat) and cadaverine on day 4 (1224 ± 435 ng/g meat) compared to the normal packaged products (647 ± 576 and 508 ± 314 ng/g meat, respectively). MAP meat revealed higher L* and TBARS values and lower microbial counts than the vacuum packaged products on all days. The MAP meat also showed lower a* results on days 4 and 8 and higher metmyoglobin (metMb) values on days 8 and 12 compared to th E: vacuum products. In the inoculation study, the microbial counts of the turkey meat were comparable between the two film types. The study showed that the nano-silver coating did not exhibit any advantageous effects on the quality and microbiological parameters of the turkey meat. © 2016 Poultry Science Association Inc.
ERIC Educational Resources Information Center
Technology Teacher, 1991
1991-01-01
Each technology learning activity in this article includes content description, objectives, required materials, challenge, and evaluation questions. Subjects are designing product packages and communication through advertising. (SK)
Risk Management of Microelectronics: The NASA Electronic Parts and Packaging (NEPP) Program
NASA Technical Reports Server (NTRS)
LaBel, Kenneth A.; Sampson, Michael J.
2005-01-01
This viewgraph information provides information on how the NASA Electronic Parts and Packaging (NEPP) Program evaluates the reliability of technologies for Electrical, Electronic, and Electromechanical (EEE) parts, and their suitability for spacecraft applications.
Design and evaluation of thin metal surface insulation for hypersonic flight
NASA Technical Reports Server (NTRS)
Miller, R. C.; Petach, A. M.
1976-01-01
An all-metal insulation was studied as a thermal protection system for hypersonic vehicles. Key program goals included fabricating the insulation in thin packages which are optimized for high temperature insulation of an actively cooled aluminum structure, and the use of state-of-the-art alloys. The insulation was fabricated from 300 series stainless steel in thicknesses of 0.8 to 12 mm. The outer, 0.127 mm thick, skin was textured to accommodate thermal expansion and oxidized to increase emittance. The thin insulating package was achieved using an insulation concept consisting of foil radiation shields spaced within the package, and conical foil supports to carry loads from the skin and maintain package dimensions. Samples of the metal-insulation were tested to evaluate thermal insulation capability, rain and sand erosion resistance, high temperature oxidation resistance, applied load capability, and high temperature emittance.
Gel, Bernat; Díez-Villanueva, Anna; Serra, Eduard; Buschbeck, Marcus; Peinado, Miguel A; Malinverni, Roberto
2016-01-15
Statistically assessing the relation between a set of genomic regions and other genomic features is a common challenging task in genomic and epigenomic analyses. Randomization based approaches implicitly take into account the complexity of the genome without the need of assuming an underlying statistical model. regioneR is an R package that implements a permutation test framework specifically designed to work with genomic regions. In addition to the predefined randomization and evaluation strategies, regioneR is fully customizable allowing the use of custom strategies to adapt it to specific questions. Finally, it also implements a novel function to evaluate the local specificity of the detected association. regioneR is an R package released under Artistic-2.0 License. The source code and documents are freely available through Bioconductor (http://www.bioconductor.org/packages/regioneR). rmalinverni@carrerasresearch.org. © The Author 2015. Published by Oxford University Press.
Mengue, Sotero Serrate; Bertoldi, Andréa Dâmaso; Boing, Alexandra Crispim; Tavares, Noemia Urruth Leão; Pizzol, Tatiane da Silva Dal; Oliveira, Maria Auxiliadora; Arrais, Paulo Sérgio Dourado; Ramos, Luiz Roberto; Farias, Mareni Rocha; Luiza, Vera Lucia; Bernal, Regina Tomie Ivata; de Barros, Aluísio Jardim Dornellas
2016-01-01
ABSTRACT OBJECTIVE To describe methodological aspects of the household survey National Survey on Access, Use and Promotion of Rational Use of Medicines (PNAUM) related to sampling design and implementation, the actual obtained sample, instruments and fieldwork. METHODS A cross-sectional, population-based study with probability sampling in three stages of the population living in households located in Brazilian urban areas. Fieldwork was carried out between September 2013 and February 2014. The data collection instrument included questions related to: information about households, residents and respondents; chronic diseases and medicines used; use of health services; acute diseases and events treated with drugs; use of contraceptives; use of pharmacy services; behaviors that may affect drug use; package inserts and packaging; lifestyle and health insurance. RESULTS In total, 41,433 interviews were carried out in 20,404 households and 576 urban clusters corresponding to 586 census tracts distributed in the five Brazilian regions, according to eight domains defined by age and gender. CONCLUSIONS The results of the survey may be used as a baseline for future studies aiming to assess the impact of government action on drug access and use. For local studies using a compatible method, PNAUM may serve as a reference point to evaluate variations in space and population. With a comprehensive evaluation of drug-related aspects, PNAUM is a major source of data for a variety of analyses to be carried out both at academic and government level. PMID:27982381
Constructing Benchmark Databases and Protocols for Medical Image Analysis: Diabetic Retinopathy
Kauppi, Tomi; Kämäräinen, Joni-Kristian; Kalesnykiene, Valentina; Sorri, Iiris; Uusitalo, Hannu; Kälviäinen, Heikki
2013-01-01
We address the performance evaluation practices for developing medical image analysis methods, in particular, how to establish and share databases of medical images with verified ground truth and solid evaluation protocols. Such databases support the development of better algorithms, execution of profound method comparisons, and, consequently, technology transfer from research laboratories to clinical practice. For this purpose, we propose a framework consisting of reusable methods and tools for the laborious task of constructing a benchmark database. We provide a software tool for medical image annotation helping to collect class label, spatial span, and expert's confidence on lesions and a method to appropriately combine the manual segmentations from multiple experts. The tool and all necessary functionality for method evaluation are provided as public software packages. As a case study, we utilized the framework and tools to establish the DiaRetDB1 V2.1 database for benchmarking diabetic retinopathy detection algorithms. The database contains a set of retinal images, ground truth based on information from multiple experts, and a baseline algorithm for the detection of retinopathy lesions. PMID:23956787
Tu, Yun; Ye, Lin; Zhou, Shao-Ping; Tu, Shan-Tung
2017-01-01
Local strain measurements are considered as an effective method for structural health monitoring of high-temperature components, which require accurate, reliable and durable sensors. To develop strain sensors that can be used in higher temperature environments, an improved metal-packaged strain sensor based on a regenerated fiber Bragg grating (RFBG) fabricated in hydrogen (H2)-loaded boron–germanium (B–Ge) co-doped photosensitive fiber is developed using the process of combining magnetron sputtering and electroplating, addressing the limitation of mechanical strength degradation of silica optical fibers after annealing at a high temperature for regeneration. The regeneration characteristics of the RFBGs and the strain characteristics of the sensor are evaluated. Numerical simulation of the sensor is conducted using a three-dimensional finite element model. Anomalous decay behavior of two regeneration regimes is observed for the FBGs written in H2-loaded B–Ge co-doped fiber. The strain sensor exhibits good linearity, stability and repeatability when exposed to constant high temperatures of up to 540 °C. A satisfactory agreement is obtained between the experimental and numerical results in strain sensitivity. The results demonstrate that the improved metal-packaged strain sensors based on RFBGs in H2-loaded B–Ge co-doped fiber provide great potential for high-temperature applications by addressing the issues of mechanical integrity and packaging. PMID:28241465
Tu, Yun; Ye, Lin; Zhou, Shao-Ping; Tu, Shan-Tung
2017-02-23
Local strain measurements are considered as an effective method for structural health monitoring of high-temperature components, which require accurate, reliable and durable sensors. To develop strain sensors that can be used in higher temperature environments, an improved metal-packaged strain sensor based on a regenerated fiber Bragg grating (RFBG) fabricated in hydrogen (H₂)-loaded boron-germanium (B-Ge) co-doped photosensitive fiber is developed using the process of combining magnetron sputtering and electroplating, addressing the limitation of mechanical strength degradation of silica optical fibers after annealing at a high temperature for regeneration. The regeneration characteristics of the RFBGs and the strain characteristics of the sensor are evaluated. Numerical simulation of the sensor is conducted using a three-dimensional finite element model. Anomalous decay behavior of two regeneration regimes is observed for the FBGs written in H₂-loaded B-Ge co-doped fiber. The strain sensor exhibits good linearity, stability and repeatability when exposed to constant high temperatures of up to 540 °C. A satisfactory agreement is obtained between the experimental and numerical results in strain sensitivity. The results demonstrate that the improved metal-packaged strain sensors based on RFBGs in H₂-loaded B-Ge co-doped fiber provide great potential for high-temperature applications by addressing the issues of mechanical integrity and packaging.
Nithya, V; Murthy, P S K; Halami, P M
2013-08-01
An attempt was made to evaluate the effectiveness of partially purified antibacterial peptide (ppABP) produced by Bacillus licheniformis Me1 for food preservation by means of active packaging. The active packaging films containing ppABP were developed using two different packing materials [low-density polyethylene (LDPE) and cellulose films] by two different methods: soaking and spread coating. The activated films showed antibacterial activity against pathogens. The release study of ppABP from coated film showed that the LDPE films liberated ppABP as soon as it comes in contact with water, while gradual release of coated ppABP was observed in case of cellulose films. The activated films showed residual activity in different simulating conditions, such as pH of food and storage temperatures. The activated films demonstrated its biopreservative efficacy in controlling the growth of pathogens in cheese and paneer. The ppABP-activated films were found to be effective for biopreservation. The ppABP from active films got diffused into the food matrix and reduced the growth rate and maximum growth population of the target micro-organism. Both types of ppABP-activated films can be used as a packaging material to control spoilage and pathogenic organisms in food, thereby extending the shelf life of foods. © 2013 The Society for Applied Microbiology.
Information Flow Integrity for Systems of Independently-Developed Components
2015-06-22
We also examined three programs (Apache, MySQL , and PHP) in detail to evaluate the efficacy of using the provided package test suites to generate...method are just as effective as hooks that were manually placed over the course of years while greatly reducing the burden on programmers. ”Leveraging...to validate optimizations of real-world, mature applications: the Apache software suite, the Mozilla Suite, and the MySQL database. ”Validating Library
NASA Technical Reports Server (NTRS)
1975-01-01
Experiment hardware and operational requirements for space shuttle experiments are discussed along with payload and system concepts. Appendixes are included in which experiment data sheets, chamber environmental control and monitoring, method for collection and storage of electrophoretically-separated samples, preliminary thermal evaluation of electromagnetic levitation facilities L1, L2, and L3, and applicable industrial automation equipment are discussed.
ASP: Automated symbolic computation of approximate symmetries of differential equations
NASA Astrophysics Data System (ADS)
Jefferson, G. F.; Carminati, J.
2013-03-01
A recent paper (Pakdemirli et al. (2004) [12]) compared three methods of determining approximate symmetries of differential equations. Two of these methods are well known and involve either a perturbation of the classical Lie symmetry generator of the differential system (Baikov, Gazizov and Ibragimov (1988) [7], Ibragimov (1996) [6]) or a perturbation of the dependent variable/s and subsequent determination of the classical Lie point symmetries of the resulting coupled system (Fushchych and Shtelen (1989) [11]), both up to a specified order in the perturbation parameter. The third method, proposed by Pakdemirli, Yürüsoy and Dolapçi (2004) [12], simplifies the calculations required by Fushchych and Shtelen's method through the assignment of arbitrary functions to the non-linear components prior to computing symmetries. All three methods have been implemented in the new MAPLE package ASP (Automated Symmetry Package) which is an add-on to the MAPLE symmetry package DESOLVII (Vu, Jefferson and Carminati (2012) [25]). To our knowledge, this is the first computer package to automate all three methods of determining approximate symmetries for differential systems. Extensions to the theory have also been suggested for the third method and which generalise the first method to systems of differential equations. Finally, a number of approximate symmetries and corresponding solutions are compared with results in the literature.
Liu, Chao; Abu-Jamous, Basel; Brattico, Elvira; Nandi, Asoke K
2017-03-01
In the past decades, neuroimaging of humans has gained a position of status within neuroscience, and data-driven approaches and functional connectivity analyses of functional magnetic resonance imaging (fMRI) data are increasingly favored to depict the complex architecture of human brains. However, the reliability of these findings is jeopardized by too many analysis methods and sometimes too few samples used, which leads to discord among researchers. We propose a tunable consensus clustering paradigm that aims at overcoming the clustering methods selection problem as well as reliability issues in neuroimaging by means of first applying several analysis methods (three in this study) on multiple datasets and then integrating the clustering results. To validate the method, we applied it to a complex fMRI experiment involving affective processing of hundreds of music clips. We found that brain structures related to visual, reward, and auditory processing have intrinsic spatial patterns of coherent neuroactivity during affective processing. The comparisons between the results obtained from our method and those from each individual clustering algorithm demonstrate that our paradigm has notable advantages over traditional single clustering algorithms in being able to evidence robust connectivity patterns even with complex neuroimaging data involving a variety of stimuli and affective evaluations of them. The consensus clustering method is implemented in the R package "UNCLES" available on http://cran.r-project.org/web/packages/UNCLES/index.html .
Siqueira, Maria C; Coelho, Gustavo F; de Moura, Márcia R; Bresolin, Joana D; Hubinger, Silviane Z; Marconcini, José M; Mattoso, Luiz H C
2014-07-01
In this study, silver nanoparticles were prepared and incorporated into carboxymethylcellulose films to evaluate the antimicrobial activity for food packaging applications. The techniques carried out for material characterization were: infrared spectroscopy and thermal analysis for the silver nanoparticles and films, as well as particle size distribution for the nanoparticles and water vapor permeability for the films. The antimicrobial activity of silver nanoparticles prepared by casting method was investigated. The minimum inhibitory concentration (MIC) value of the silver nanoparticles to test Gram-positive (Enterococcus faecalis) and Gram-negative (Escherichia coli) microorganisms was carried out by the serial dilution technique, tested in triplicate to confirm the concentration used. The results were developed using the Mcfarland scale which indicates that the presence or absence of turbidity tube demonstrates the inhibition of bacteria in relation to the substance inoculated. It was found that the silver nanoparticles inhibited the growth of the tested microorganisms. The carboxymethylcellulose film embedded with silver nanoparticles showed the best antimicrobial effect against Gram-positive (E. faecalis) and Gram-negative (E. coli) bacteria (0.1 microg cm(-3)).
Volatilisation and oxidation of aluminium scraps fed into incineration furnaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biganzoli, Laura, E-mail: laura.biganzoli@mail.polimi.it; Gorla, Leopoldo; Nessi, Simone
Highlights: Black-Right-Pointing-Pointer Aluminium packaging partitioning in MSW incineration residues is evaluated. Black-Right-Pointing-Pointer The amount of aluminium packaging recoverable from the bottom ashes is evaluated. Black-Right-Pointing-Pointer Aluminium packaging oxidation rate in the residues of MSW incineration is evaluated. Black-Right-Pointing-Pointer 80% of aluminium cans, 51% of trays and 27% of foils can be recovered from bottom ashes. - Abstract: Ferrous and non-ferrous metal scraps are increasingly recovered from municipal solid waste incineration bottom ash and used in the production of secondary steel and aluminium. However, during the incineration process, metal scraps contained in the waste undergo volatilisation and oxidation processes, which determinemore » a loss of their recoverable mass. The present paper evaluates the behaviour of different types of aluminium packaging materials in a full-scale waste to energy plant during standard operation. Their partitioning and oxidation level in the residues of the incineration process are evaluated, together with the amount of potentially recoverable aluminium. About 80% of post-consumer cans, 51% of trays and 27% of foils can be recovered through an advanced treatment of bottom ash combined with a melting process in the saline furnace for the production of secondary aluminium. The residual amount of aluminium concentrates in the fly ash or in the fine fraction of the bottom ash and its recovery is virtually impossible using the current eddy current separation technology. The average oxidation levels of the aluminium in the residues of the incineration process is equal to 9.2% for cans, 17.4% for trays and 58.8% for foils. The differences between the tested packaging materials are related to their thickness, mechanical strength and to the alloy.« less
Robust identification of polyethylene terephthalate (PET) plastics through Bayesian decision.
Zulkifley, Mohd Asyraf; Mustafa, Mohd Marzuki; Hussain, Aini; Mustapha, Aouache; Ramli, Suzaimah
2014-01-01
Recycling is one of the most efficient methods for environmental friendly waste management. Among municipal wastes, plastics are the most common material that can be easily recycled and polyethylene terephthalate (PET) is one of its major types. PET material is used in consumer goods packaging such as drinking bottles, toiletry containers, food packaging and many more. Usually, a recycling process is tailored to a specific material for optimal purification and decontamination to obtain high grade recyclable material. The quantity and quality of the sorting process are limited by the capacity of human workers that suffer from fatigue and boredom. Several automated sorting systems have been proposed in the literature that include using chemical, proximity and vision sensors. The main advantages of vision based sensors are its environmentally friendly approach, non-intrusive detection and capability of high throughput. However, the existing methods rely heavily on deterministic approaches that make them less accurate as the variations in PET plastic waste appearance are too high. We proposed a probabilistic approach of modeling the PET material by analyzing the reflection region and its surrounding. Three parameters are modeled by Gaussian and exponential distributions: color, size and distance of the reflection region. The final classification is made through a supervised training method of likelihood ratio test. The main novelty of the proposed method is the probabilistic approach in integrating various PET material signatures that are contaminated by stains under constant lighting changes. The system is evaluated by using four performance metrics: precision, recall, accuracy and error. Our system performed the best in all evaluation metrics compared to the benchmark methods. The system can be further improved by fusing all neighborhood information in decision making and by implementing the system in a graphics processing unit for faster processing speed.
Robust Identification of Polyethylene Terephthalate (PET) Plastics through Bayesian Decision
Zulkifley, Mohd Asyraf; Mustafa, Mohd Marzuki; Hussain, Aini; Mustapha, Aouache; Ramli, Suzaimah
2014-01-01
Recycling is one of the most efficient methods for environmental friendly waste management. Among municipal wastes, plastics are the most common material that can be easily recycled and polyethylene terephthalate (PET) is one of its major types. PET material is used in consumer goods packaging such as drinking bottles, toiletry containers, food packaging and many more. Usually, a recycling process is tailored to a specific material for optimal purification and decontamination to obtain high grade recyclable material. The quantity and quality of the sorting process are limited by the capacity of human workers that suffer from fatigue and boredom. Several automated sorting systems have been proposed in the literature that include using chemical, proximity and vision sensors. The main advantages of vision based sensors are its environmentally friendly approach, non-intrusive detection and capability of high throughput. However, the existing methods rely heavily on deterministic approaches that make them less accurate as the variations in PET plastic waste appearance are too high. We proposed a probabilistic approach of modeling the PET material by analyzing the reflection region and its surrounding. Three parameters are modeled by Gaussian and exponential distributions: color, size and distance of the reflection region. The final classification is made through a supervised training method of likelihood ratio test. The main novelty of the proposed method is the probabilistic approach in integrating various PET material signatures that are contaminated by stains under constant lighting changes. The system is evaluated by using four performance metrics: precision, recall, accuracy and error. Our system performed the best in all evaluation metrics compared to the benchmark methods. The system can be further improved by fusing all neighborhood information in decision making and by implementing the system in a graphics processing unit for faster processing speed. PMID:25485630
Development and evaluation of a wheelchair service provision training of trainers programme
2017-01-01
Background In many countries, availability of basic training and continued professional development programmes in wheelchair services is limited. Therefore, many health professionals lack access to formal training opportunities and new approaches to improve wheelchair service provision. To address this need, the World Health Organization (WHO) developed the WHO Wheelchair Service Training of Trainers Programme (WSTPt), aiming to increase the number of trainers who are well prepared to deliver the WHO Wheelchair Service Training Packages. Despite these efforts, there was no recognised method to prepare trainers to facilitate these training programmes in a standardised manner. Objectives To understand if the WSTPt is an effective mechanism to train aspiring wheelchair service provision trainers. Method An action research study was conducted using a mixed-methods approach to data collection and analysis to integrate feedback from questionnaires and focus groups from three WHO WSTPt pilots. Results Trainees were satisfied with the WHO WSTPt and the iterative process appears to have helped to improve each subsequent pilot and the final training package. Conclusion The WHO WSTPt is an effective mechanism to train wheelchair service provision trainers. This programme has potential to increase the number of trainees and may increase the number of qualified service providers. PMID:28936423
THE CAUSAL ANALYSIS / DIAGNOSIS DECISION ...
CADDIS is an on-line decision support system that helps investigators in the regions, states and tribes find, access, organize, use and share information to produce causal evaluations in aquatic systems. It is based on the US EPA's Stressor Identification process which is a formal method for identifying causes of impairments in aquatic systems. CADDIS 2007 increases access to relevant information useful for causal analysis and provides methods and tools that practitioners can use to analyze their own data. The new Candidate Cause section provides overviews of commonly encountered causes of impairments to aquatic systems: metals, sediments, nutrients, flow alteration, temperature, ionic strength, and low dissolved oxygen. CADDIS includes new Conceptual Models that illustrate the relationships from sources to stressors to biological effects. An Interactive Conceptual Model for phosphorus links the diagram with supporting literature citations. The new Analyzing Data section helps practitioners analyze their data sets and interpret and use those results as evidence within the USEPA causal assessment process. Downloadable tools include a graphical user interface statistical package (CADStat), and programs for use with the freeware R statistical package, and a Microsoft Excel template. These tools can be used to quantify associations between causes and biological impairments using innovative methods such as species-sensitivity distributions, biological inferenc
Kulwa, Kissa B M; Verstraeten, Roosmarijn; Bouckaert, Kimberley P; Mamiro, Peter S; Kolsteren, Patrick W; Lachat, Carl
2014-10-16
Strategies to improve infant and young child nutrition in low- and middle- income countries need to be implemented at scale. We contextualised and packaged successful strategies into a feasible intervention for implementation in rural Tanzania. Opportunities that can optimise delivery of the intervention and encourage behaviour change include mothers willingness to modifying practices; support of family members; seasonal availability and accessibility of foods; established set-up of village peers and functioning health system. The primary objective of the study is to evaluate the effectiveness of a nutrition education package in improving feeding practices, dietary adequacy and growth as compared to routine health education. A parallel cluster randomised controlled trial will be conducted in rural central Tanzania in 9 intervention and 9 control villages. The control group will receive routine health education offered monthly by health staff at health facilities. The intervention group will receive a nutrition education package in addition to the routine health education. The education package is comprised of four components: 1) education and counselling of mothers, 2) training community-based nutrition counsellors and monthly home visits, 3) sensitisation meetings with health staff and family members, and 4) supervision of community-based nutrition counsellors. The duration of the intervention is 9 months and infants will be recruited at 6 months of age. Primary outcome (linear growth as length-for-age Z-scores) and secondary outcomes (changes in weight-for-length Z-scores; mean intake of energy, fat, iron and zinc from complementary foods; proportion of children consuming 4 or more food groups and recommended number of semi-solid/soft meals and snacks per day; maternal level of knowledge and performance of recommended practices) will be assessed at baseline and ages 9, 12 and 15 months. Process evaluation will document reach, dose and fidelity of the intervention and context at 8 and 15 months. Results of the trial will provide evidence of the effectiveness of the nutrition education package in community settings of rural Tanzania. They will provide recommendations for strengthening the nutrition component of health education in child health services. ClinicalTrials.gov Identifier: NCT02249754, September 25, 2014.
2014-01-01
Background Research demonstrates that tobacco packaging elements (including health warning labels, descriptive characteristics, and corporate branding) are associated with knowledge of health risks and product appeal with cigarettes. Yet, little research has assessed this with smokeless tobacco (SLT) packaging. This study evaluates the association between three SLT packaging elements with knowledge of health risks and perceptions of novelty and appeal. Additionally, we assess how effects of these messages may differ across age groups, including youth (14-17 years), young adults (18-25 years), and older adults (26-65 years). Methods 1000 participants were administered a web-based survey in 2010 and shown three sets of SLT packs in random order, varied by descriptor (flavor descriptor vs. none), warning label format (graphic vs. text), and corporate branding (branded vs. plain packaging). Participants rated the packs compared with “no difference” on appeal, novelty, and risk perceptions associated with product use. Chi-square tests were used to test for significant differences in pack selections. Multinomial regression was employed to evaluate the association between effects of packaging elements and participant age. Results More respondents selected the pack with the graphic warning label as the pack to make them consider the health risks associated with SLT use, attract their attention, and be least attractive to a smoker. The product with the text warning label was the product someone their age would want to be seen using and would appeal to peers. The SLT pack with the flavor descriptor was not associated with health risks associated with product use. The pack with corporate branding was selected as more appealing, to attract attention, and one they would want to be seen using; the plain pack was less attractive to smokers. Youth and young adults were more likely to indicate that pack elements affected their perceptions of appeal and risk associated with SLT products. Conclusion These results suggest that SLT pack characteristics have a measurable effect on perceptions of health risk and product appeal. Future research should assess these findings in the context of harm reduction. Specifically, research is needed to determine whether pack elements on SLT products can effectively convey risk and harm. PMID:24433301
NASA Astrophysics Data System (ADS)
Jackson, Chester W.; Alexander, Clark R.; Bush, David M.
2012-04-01
The AMBUR (Analyzing Moving Boundaries Using R) package for the R software environment provides a collection of functions for assisting with analyzing and visualizing historical shoreline change. The package allows import and export of geospatial data in ESRI shapefile format, which is compatible with most commercial and open-source GIS software. The "baseline and transect" method is the primary technique used to quantify distances and rates of shoreline movement, and to detect classification changes across time. Along with the traditional "perpendicular" transect method, two new transect methods, "near" and "filtered," assist with quantifying changes along curved shorelines that are problematic for perpendicular transect methods. Output from the analyses includes data tables, graphics, and geospatial data, which are useful in rapidly assessing trends and potential errors in the dataset. A forecasting function also allows the user to estimate the future location of the shoreline and store the results in a shapefile. Other utilities and tools provided in the package assist with preparing and manipulating geospatial data, error checking, and generating supporting graphics and shapefiles. The package can be customized to perform additional statistical, graphical, and geospatial functions, and, it is capable of analyzing the movement of any boundary (e.g., shorelines, glacier terminus, fire edge, and marine and terrestrial ecozones).
Unitizing goods on pallets and slipsheets
J. F. Laundrie
1986-01-01
Packaging, handling, and shipping methods and facilities have changed drastically since World War II. Today, most products are individually packaged and then combined into unitized loads for more efficient handling, storage, and shipping. The purpose of this manual is to promote the most effective use of wood and wood fiber in current packaging and shipping practices...
fgui: A Method for Automatically Creating Graphical User Interfaces for Command-Line R Packages
Hoffmann, Thomas J.; Laird, Nan M.
2009-01-01
The fgui R package is designed for developers of R packages, to help rapidly, and sometimes fully automatically, create a graphical user interface for a command line R package. The interface is built upon the Tcl/Tk graphical interface included in R. The package further facilitates the developer by loading in the help files from the command line functions to provide context sensitive help to the user with no additional effort from the developer. Passing a function as the argument to the routines in the fgui package creates a graphical interface for the function, and further options are available to tweak this interface for those who want more flexibility. PMID:21625291
A systematic review of substance misuse assessment packages.
Sweetman, Jennifer; Raistrick, Duncan; Mdege, Noreen D; Crosby, Helen
2013-07-01
Health-care systems globally are moving away from process measures of performance to payments for outcomes achieved. It follows that there is a need for a selection of proven quality tools that are suitable for undertaking comprehensive assessments and outcomes assessments. This review aimed to identify and evaluate existing comprehensive assessment packages. The work is part of a national program in the UK, Collaborations in Leadership of Applied Health Research and Care. Systematic searches were carried out across major databases to identify instruments designed to assess substance misuse. For those instruments identified, searches were carried out using the Cochrane Library, Embase, Ovid MEDLINE(®) and PsychINFO to identify articles reporting psychometric data. From 595 instruments, six met the inclusion criteria: Addiction Severity Index; Chemical Use, Abuse and Dependence Scale; Form 90; Maudsley Addiction Profile; Measurements in the Addictions for Triage and Evaluation; and Substance Abuse Outcomes Module. The most common reasons for exclusion were that instruments were: (i) designed for a specific substance (239); (ii) not designed for use in addiction settings (136); (iii) not providing comprehensive assessment (89); and (iv) not suitable as an outcome measure (20). The six packages are very different and suited to different uses. No package had adequate evaluation of their properties and so the emphasis should be on refining a small number of tools with very general application rather than creating new ones. An alternative to using 'off-the-shelf' packages is to create bespoke packages from well-validated, single-construct scales. [ © 2013 Australasian Professional Society on Alcohol and other Drugs.
Food-packaging interactions influencing quality and safety.
Hotchkiss, J H
1997-01-01
Interactions between foods and packaging can be detrimental to quality and/or safety. Changes in product flavour due to aroma sorption and the transfer of undesirable flavours from packaging to foods are important mechanisms of deterioration when foods are packaged in polymer-based materials. Careful consideration must be given to those factors affecting such interactions when selecting packaging materials in order to maximize product quality, safety, and shelf-life while minimizing undesirable changes. Product considerations include sensitivity to flavour and related deteriorations, colour changes, vitamin loss, microbial activity, and amount of flavour available. Storage considerations include temperature, time, and processing method. Polymer considerations include type of polymer and processing method, volume or mass of polymer to product ratio, and whether the interaction is Fickian or non-Fickian. Methodology to determine the extent of such interactions must be developed. Direct interactions between food and packaging are not necessarily detrimental. The same principles governing undesirable interactions can be used to affect desirable outcomes. Examples include films which directly intercept or absorb oxygen, inhibit microorganisms, remove undesirable flavours by sorption, or indicate safety and product shelf-life.
Consumer acceptance of fresh blueberries in bio-based packages.
Almenar, Eva; Samsudin, Hayati; Auras, Rafael; Harte, Janice
2010-05-01
Instrumental analyses have shown that non-vented bio-based containers made from poly(lactic acid) (PLA) have the capability to enhance blueberry shelf life as compared with commercial vented petroleum-based clamshell containers. However, consumer preference has not been explored so far. In this study, two sensory evaluations, triangle and paired preference tests, were performed after storing fruit in both containers at 3 and 10 degrees C for 7 and 14 days. In addition, physicochemical analyses were performed after each tasting in order to correlate instrumental findings with consumer preference. The results of the triangle test showed the capability of the consumer to differentiate (P < or = 0.001) between blueberries from different packages at both storage temperatures. A consumer preference for flavour, texture, external appearance and overall quality (P < or = 0.001) of blueberries packaged in PLA containers was observed in the paired comparison test. The instrumental analyses showed that blueberries in the PLA packages exhibited a weight loss below the limit for marketable life, a stable soluble solid content and titratable acidity and no fungal growth during storage. Consumers distinguished between blueberries from different packages and preferred those packaged in the PLA containers. The instrumental analyses showed that the usable life of the berries was extended in the PLA containers. A correlation between consumer preference and instrumental evaluations was found.
Method Of Packaging And Assembling Electro-Microfluidic Devices
Benavides, Gilbert L.; Galambos, Paul C.; Emerson, John A.; Peterson, Kenneth A.; Giunta, Rachel K.; Zamora, David Lee; Watson, Robert D.
2004-11-23
A new architecture for packaging surface micromachined electro-microfluidic devices is presented. This architecture relies on two scales of packaging to bring fluid to the device scale (picoliters) from the macro-scale (microliters). The architecture emulates and utilizes electronics packaging technology. The larger package consists of a circuit board with embedded fluidic channels and standard fluidic connectors (e.g. Fluidic Printed Wiring Board). The embedded channels connect to the smaller package, an Electro-Microfluidic Dual-Inline-Package (EMDIP) that takes fluid to the microfluidic integrated circuit (MIC). The fluidic connection is made to the back of the MIC through Bosch-etched holes that take fluid to surface micromachined channels on the front of the MIC. Electrical connection is made to bond pads on the front of the MIC.
Apparatus and method for skin packaging articles
NASA Technical Reports Server (NTRS)
Madsen, B.; Pozsony, E. R.; Collin, E. E. (Inventor)
1973-01-01
A system for skin packaging articles including a loading zone for positioning articles to be packaged upon a substrate, a thermoplastic film heating and vacuum operated skin packaging zone for covering the articles with film laminated to the substrate and a slitting zone for separating and trimming the individual skin packaged articles. The articles are passed to the successive zones. The loading zone may be adapted for conveyorized instead of hand loading. In some cases, where only transverse cutting of the film web is necessary, it may be desirable to eliminate the slitting zone and remove the skin packaged article or articles directly from the packaging zone. A conveniently located operating panel contains controls for effecting automatic, semiautomatic or manual operation of the entire system of any portions in any manner desired.
Packaging and Labeling of Pharmaceutical Products Obtained from the Internet
2011-01-01
Background For patients, the prescription container label may be the only source of instructions on how to take their medicines. In the United States, the legal requirements for a prescription label are set by federal law and state statutes. The container should be comparable to that which manufacturers use to package drug products and should preserve a product’s identity, strength, quality, and purity and prevent contamination. Safety features such as a child-resistant closure should be provided. Pharmaceutical products purchased from international online pharmacies are not approved by the Food and Drug Administration (FDA) and may not meet US guidelines for labeling and packaging. Objective The study objective was to determine whether commonly purchased pharmaceutical products obtained from international online pharmacies are comparable to products dispensed in the United States with regard to labeling and packaging. Methods During March 2006 through January 2007, 41 pharmaceutical oral dosage form samples were obtained from international Internet pharmacy websites for evaluation: 18 generic simvastatin samples, 18 generic amlodipine samples, and 5 generic sildenafil samples. Contents for each package were observed and recorded and comparison of the prescription labeling and packaging of these products was made with prescription labeling and packaging requirements in the United States. Results Of the 41 drug products obtained from online pharmacies from 12 different countries, only 1 product (from Canada) would meet both labeling and packaging guidelines for products dispensed in the United States. Of those not meeting the requirements, 7 were dispensed in paper envelopes with label affixed that was either handwritten or typed and contained missing information such as name and address of dispenser, name of prescriber, name of patient, and directions for use. Another 3 products did not have a label affixed to the drug product, but information was printed on a paper document enclosed in the shipping package, while 28 products did not have labels affixed to the drug product. In all, 39 of the 41 drug products’ packaging would not meet the US guidelines. Aside from the Canadian product, only 1 product from Mexico was dispensed in a container that would meet guidelines established in the United States. In total, 35 products were not dispensed in plastic vials but were dispensed in unit dose packages, paper envelopes with loose dosage forms, blister packs of drugs held together with rubber bands, or a combination of these packaging forms. Conclusions Results suggest that labeling and packaging standards for international generic drug products are not equivalent to labeling and packaging standards in the United States. This suggests dissimilar and substandard distribution processes compared with those in the United States, which in turn presents a challenge to patient comprehension and health literacy and may affect patient adherence to drug treatment regimens. These findings have strong implications for drug product quality, patient outcomes, therapeutic effectiveness, and safety. PMID:21324833
The kinship2 R package for pedigree data.
Sinnwell, Jason P; Therneau, Terry M; Schaid, Daniel J
2014-01-01
The kinship2 package is restructured from the previous kinship package. Existing features are now enhanced and new features added for handling pedigree objects. Pedigree plotting features have been updated to display features on complex pedigrees while adhering to pedigree plotting standards. Kinship matrices can now be calculated for the X chromosome. Other methods have been added to subset and trim pedigrees while maintaining the pedigree structure. We make the kinship2 package available for R on the Contributed R Archives Network (CRAN), where data management is built-in and other packages can use the pedigree object.
Equivalent Safety Basis for Evaluation of On-Site Packages for US DOE Facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, A.C.
Packages for transport of radioactive material within the boundaries of a Department of Energy facility (on-site) must conform to the requirements for packages shipped in normal commerce, or must provide equivalent safety. Equivalence is achieved if the frequency of severe on-site accidents, which could result in a release of radioactive material, is less than or equal to the frequency of Beyond-HAC accidents for packages in commerce. This is shown to be achieved it the rate of on-site accident is 22 per 100 MVM or lower. For equivalence to Normal Conditions of Transport, for on-site packages, appropriate, defensible Design Basis Conditionsmore » can be established and the ability of the package to meet the reduced requirements shown in the On-site Safety Assessment.« less
McCotter, L; Douglas, P; Laur, C; Gandy, J; Fitzpatrick, L; Rajput-Ray, M; Ray, S
2016-01-01
Objectives To (1) assess the hydration knowledge, attitudes and practices (KAP) of doctors; (2) develop an evidence-based training package; and (3) evaluate the impact of the training package. Design Educational intervention with impact evaluation. Setting Cambridgeshire, UK. Participants General practitioners (GPs (primary care physicians)). Interventions Hydration and healthcare training. Main outcome measures Hydration KAP score before and immediately after the training session. Results Knowledge gaps of doctors identified before the teaching were the definition of dehydration, European Food Safety Authority water intake recommendations, water content of the human body and proportion of water from food and drink. A face-to-face teaching package was developed on findings from the KAP survey and literature search. 54 questionnaires were completed before and immediately after two training sessions with GPs. Following the training, total hydration KAP scores increased significantly (p<0.001; median (25th, 75th centiles); 32 (29, 34)). Attendees rated the session as excellent or good (90%) and reported the training was likely to influence their professional practice (100%). Conclusions The training package will continue to be developed and adapted, with increased focus on follow-up strategies as well as integration into medical curricula and standards of practice. However, further research is required in the area of hydration care to allow policymakers to incorporate hydration awareness and care with greater precision in local and national policies. PMID:27927656
Parallelization of Rocket Engine System Software (Press)
NASA Technical Reports Server (NTRS)
Cezzar, Ruknet
1996-01-01
The main goal is to assess parallelization requirements for the Rocket Engine Numeric Simulator (RENS) project which, aside from gathering information on liquid-propelled rocket engines and setting forth requirements, involve a large FORTRAN based package at NASA Lewis Research Center and TDK software developed by SUBR/UWF. The ultimate aim is to develop, test, integrate, and suitably deploy a family of software packages on various aspects and facets of rocket engines using liquid-propellants. At present, all project efforts by the funding agency, NASA Lewis Research Center, and the HBCU participants are disseminated over the internet using world wide web home pages. Considering obviously expensive methods of actual field trails, the benefits of software simulators are potentially enormous. When realized, these benefits will be analogous to those provided by numerous CAD/CAM packages and flight-training simulators. According to the overall task assignments, Hampton University's role is to collect all available software, place them in a common format, assess and evaluate, define interfaces, and provide integration. Most importantly, the HU's mission is to see to it that the real-time performance is assured. This involves source code translations, porting, and distribution. The porting will be done in two phases: First, place all software on Cray XMP platform using FORTRAN. After testing and evaluation on the Cray X-MP, the code will be translated to C + + and ported to the parallel nCUBE platform. At present, we are evaluating another option of distributed processing over local area networks using Sun NFS, Ethernet, TCP/IP. Considering the heterogeneous nature of the present software (e.g., first started as an expert system using LISP machines) which now involve FORTRAN code, the effort is expected to be quite challenging.
Impact of the community-based newborn care package in Nepal: a quasi-experimental evaluation
Paudel, Deepak; Shrestha, Ishwar B; Siebeck, Matthias; Rehfuess, Eva
2017-01-01
Objective To evaluate the impact of the community-based newborn care package (CBNCP) on six essential practices to improve neonatal health. Methods CBNCP pilot districts were matched to comparison districts using propensity scores. Impact on birth preparedness, antenatal care seeking, antenatal care quality, delivery by skilled birth attendant, immediate newborn care and postnatal care within 48 hours were assessed using Demographic and Health Survey (DHS) and Health Management Information System (HMIS) data through difference-in-differences and multivariate logistic regression analyses. Findings Changes over time in intervention and comparison areas were similar in difference-in-differences analysis of DHS and HMIS data. Logistic regression of DHS data also did not reveal any significant improvement in combined outcomes: birth preparedness, adjusted OR (aOR)=0.8 (95% CI 0.4 to 1.7); antenatal care seeking, aOR=1.0 (0.6 to 1.5); antenatal care quality, aOR=1.4 (0.9 to 2.1); delivery by skilled birth attendant, aOR=1.5 (1.0 to 2.3); immediate newborn care, aOR=1.1 (0.7 to 1.9); postnatal care, aOR=1.3 (0.9 to 1.9). Health providers’ knowledge and skills in intervention districts were fair but showed much variation between different providers and districts. Conclusions This study, while representing an early assessment of impact, did not identify significant improvements in newborn care practices and raises concerns regarding CBNCP implementation. It has contributed to revisions of the package and it being merged with the Integrated Management of Neonatal and Childhood Illness programme. This is now being implemented in 35 districts and carefully monitored for quality and impact. The study also highlights general challenges in evaluating the impacts of a complex health intervention under ‘real life’ conditions. PMID:28982810
[Obtaining sturgeon spawn in accordance with the German Pharmaceuticals Act].
Bräuer, G; Emmerich, I U
2014-01-01
Obtaining sturgeon spawn in aquaculture is carried out with different objectives. Sturgeons are increasingly used for ornamental purposes or to serve as food. Previously, sturgeon roe was obtained primarily by surgical opening of the abdomen or during slaughter. Recently, in aquaculture roe has been increasingly produced by stripping off the eggs. In this new method it is necessary to synchronize spawn production by stimulating the fish through hormone usage. Therefore, the complete egg package can be taken from the fish, which avoids resorption disorders. This article discusses how this method can be evaluated from the perspective of drug law.
Evaluating significance in linear mixed-effects models in R.
Luke, Steven G
2017-08-01
Mixed-effects models are being used ever more frequently in the analysis of experimental data. However, in the lme4 package in R the standards for evaluating significance of fixed effects in these models (i.e., obtaining p-values) are somewhat vague. There are good reasons for this, but as researchers who are using these models are required in many cases to report p-values, some method for evaluating the significance of the model output is needed. This paper reports the results of simulations showing that the two most common methods for evaluating significance, using likelihood ratio tests and applying the z distribution to the Wald t values from the model output (t-as-z), are somewhat anti-conservative, especially for smaller sample sizes. Other methods for evaluating significance, including parametric bootstrapping and the Kenward-Roger and Satterthwaite approximations for degrees of freedom, were also evaluated. The results of these simulations suggest that Type 1 error rates are closest to .05 when models are fitted using REML and p-values are derived using the Kenward-Roger or Satterthwaite approximations, as these approximations both produced acceptable Type 1 error rates even for smaller samples.
Code of Federal Regulations, 2013 CFR
2013-10-01
... fully evaluate evidence, all spreadsheets must be fully accessible and manipulable. Electronic databases... Microsoft Open Database Connectivity (ODBC) standard. ODBC is a Windows technology that allows a database software package to import data from a database created using a different software package. We currently...
Code of Federal Regulations, 2014 CFR
2014-10-01
... fully evaluate evidence, all spreadsheets must be fully accessible and manipulable. Electronic databases... Microsoft Open Database Connectivity (ODBC) standard. ODBC is a Windows technology that allows a database software package to import data from a database created using a different software package. We currently...
Code of Federal Regulations, 2012 CFR
2012-10-01
... fully evaluate evidence, all spreadsheets must be fully accessible and manipulable. Electronic databases... Microsoft Open Database Connectivity (ODBC) standard. ODBC is a Windows technology that allows a database software package to import data from a database created using a different software package. We currently...
Code of Federal Regulations, 2010 CFR
2010-10-01
... fully evaluate evidence, all spreadsheets must be fully accessible and manipulable. Electronic databases... Microsoft Open Database Connectivity (ODBC) standard. ODBC is a Windows technology that allows a database software package to import data from a database created using a different software package. We currently...
Pre-Mastering and CD-WO Evaluations
NASA Technical Reports Server (NTRS)
Hecox, D.; Hyon, J.; Martin, M.; Marski, K.; Shields, E.; Sorensen, S.; Teramae, S.
1993-01-01
This article reviews the features and functionality of five desktop pre-mastering software packages for the PC. Desktop pre-mastering packages are aimed primarily at end-users interested in bringing CD-ROM publishing tasks in-house, rather than traditional CD-ROM developers.
Go beyond Design by Adopting a Philosophy of Packaging Information.
ERIC Educational Resources Information Center
Kennedy, Jack
1993-01-01
Describes how a changeover to desktop publishing, working in teams, expansion of the journalism room, and the concept of packaging combined to dramatically change a high school newspaper's approach and product. Argues for a debate on evaluation services. (SR)
Vousden, Nicola; Lawley, Elodie; Nathan, Hannah L; Seed, Paul T; Brown, Adrian; Muchengwa, Tafadzwa; Charantimath, Umesh; Bellad, Mrutyunjaya; Gidiri, Muchabayiwa Francis; Goudar, Shivaprasad; Chappell, Lucy C; Sandall, Jane; Shennan, Andrew H
2018-04-27
The CRADLE-3 trial is a stepped-wedge randomised controlled trial aiming to reduce maternal mortality and morbidity by implementing a novel vital sign device (CRADLE Vital Sign Alert) and training package into routine maternity care in 10 low-income sites. The MRC Guidance on complex interventions proposes that interventions and implementation strategies be shaped by early phase piloting and development work. We present the findings of a three-month mixed-methodology feasibility study for this trial, describe how this was informed by the MRC guidance and the study design was refined. The fidelity, dose, feasibility and acceptability of implementation and training materials were assessed in three representative non-trial sites (Zimbabwe, Ethiopia, India) using multiple-choice questionnaires, evaluation of clinical management (action log), healthcare provider (HCP) semi-structured interviews and focus groups 4-10 weeks after implementation. Simultaneously, the 10 sites included in the main trial (eight countries) collected primary outcome data to inform the power calculation and randomisation allocation and assess the feasibility of data collection. The package was implemented with high fidelity (85% of HCP trained, n = 204). The questionnaires indicated a good understanding of device use with 75% of participants scoring > 75% (n = 97; 90% of those distributed). Action logs were inconsistently completed but indicated that the majority of HCP responded appropriately to abnormal results. From 18 HCP interviews and two focus groups it was widely reported that the intervention improved capacity to make clinical decisions, escalate care and make appropriate referrals. Nine of the ten main trial sites achieved ethical approval for pilot data collection. Intensive care was an inconsistent marker of morbidity and stroke an infrequent outcome and therefore they were removed from the main trial composite outcome. Tools and methods of data collection were optimized and event rates used to inform randomisation. This feasibility study demonstrates that the components of the intervention were acceptable, methods of implementing were successful and the main trial design would be feasible. Qualitative work identified key moderators that informed the main trial process evaluation. Changes to the training package, implementation strategy, study design and processes were identified to refine the implementation in the main trial. ISRCTN41244132 ; Registered 24/11/2015.
Functions of Nano-Materials in Food Packaging
NASA Astrophysics Data System (ADS)
Yap, Ray Chin Chong; Kwablah, Amegadze Paul Seyram; He, Jiating; Li, Xu
Food packaging has been changing from bulky and rigid form in the past to different variation of lights and plastic packagings. Regardless of the changes, the packaging must be able to uphold its original function which is to serve as food containment as well as to protect the food from the external environment. Coupled with the increasing consumer’s awareness on food waste, higher standard of living, technological developments are underway to enhance the shelf-life of packed food as well as methods to provide indications of food packaging environment. There are many different indicators for food spoilage, but two commonly found gases in food packaging are oxygen and carbon dioxide. Oxygen is the main mechanism for food spoilage, while carbon dioxide is often used in modified-atmosphere-packaging. There are also different methods of gas scavenging and/or sensing techniques based on different concepts in the literature. In this review, the focus will be on nano-materials, namely titanium dioxide, silica, zeolites and metal organic frameworks. This review is structured in a manner to highlight how each material can be used in both gas scavenging and/or indicators applications. The last part of the review focuses on the approach and some key considerations when integrating nano-materials into the plastic film.
Li, Hui; Yang, Jin; Li, Pan; Lan, Tianqing; Peng, Lincai
2017-03-15
We proposed a green and facile method to fabricate superhydrophobic paper in this study, which is layer-by-layer (LBL) deposition of TiO 2 nanoparticles/sodium alginate (ALG) multilayers on paper surface followed by an adsorption treatment of colloidal carnauba wax. The formation of TiO 2 /ALG multilayers on paper surface was characterized by X-ray photoelectron spectroscopy (XPS), zeta potential measurement, scanning electron microscopy (SEM) and atomic force microscopy (AFM), respectively. The wetting property of modified paper was investigated by water contact angle (WCA) measurement. Moreover, the modified paper tensile strength has been evaluated. The results showed that WCA of paper modified with a wax-treated (TiO 2 /ALG) 3.5 multilayer reached up to 151.5°, and this obtained superhydrophobic paper exhibited improved tensile strength (increased by 4.1% compared to the pristine paper), excellent moisture-proofing property and high strength stability under high relative humidity condition, which might has a great potential for use in the liquid paper packaging and moisture-proof paper packaging. Copyright © 2016 Elsevier Ltd. All rights reserved.
Snyder, Hannah; Yeldandi, Vijay V.; Kumar, G. Prem; Liao, Chuanhong; Lakshmi, Vemu; Gandham, Sabitha R.; Muppudi, Uma; Oruganti, Ganesh; Schneider, John A.
2013-01-01
In India, men who have sex with men (MSM) and truck drivers are high-risk groups that often do not access HIV testing due to stigma and high mobility. This study evaluated a field testing package (FTP) that identified HIV positive participants through video pre-test counseling, OraQuick oral fluid HIV testing, and telephonic post-test counseling and then connected them to government facilities. 598 MSM and truck drivers participated in the FTP and completed surveys covering sociodemographics, HIV testing history, risk behaviors, and opinions on the FTP. Those who had previously been tested preferred traditional methods to video counseling. MSM and truck drivers equally preferred video counseling, although MSM who had been previously tested preferred traditional methods. Nearly all participants preferred oral testing. Rates of counseling completion and linkage to government centers were low, with one third of newly identified positives completing follow-up. With increased public-private coordination, this FTP could identify many hard-to-reach preliminary positive individuals and connect them to government testing and care. PMID:22827901
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sonzogni, A.A.
2005-05-24
A package of computer codes has been developed to process and display nuclear structure and decay data stored in the ENSDF (Evaluated Nuclear Structure Data File) library. The codes were written in an object-oriented fashion using the java language. This allows for an easy implementation across multiple platforms as well as deployment on web pages. The structure of the different java classes that make up the package is discussed as well as several different implementations.
Nanostructured bioactive polymers used in food-packaging.
Mateescu, Andreea L; Dimov, Tatiana V; Grumezescu, Alexandru M; Gestal, Monica C; Chifiriuc, Mariana C
2015-01-01
The development of effective packaging materials is crucial, because food microorganisms determine economic and public health issues. The current paper describes some of the most recent findings in regards of food preservation through novel packaging methods, using biodegradable polymers, efficient antimicrobial agents and nanocomposites with improved mechanical and oxidation stability, increased biodegradability and barrier effect comparatively with conventional polymeric matrices.
yaImpute: An R package for kNN imputation
Nicholas L. Crookston; Andrew O. Finley
2008-01-01
This article introduces yaImpute, an R package for nearest neighbor search and imputation. Although nearest neighbor imputation is used in a host of disciplines, the methods implemented in the yaImpute package are tailored to imputation-based forest attribute estimation and mapping. The impetus to writing the yaImpute is a growing interest in nearest neighbor...
Zhang, Juzhou; Li, Jing; Shao, Dongliang; Yao, Bangben; Jiang, Junshu
2012-02-01
An effective high performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of 9 ultraviolet stabilizers in food plastic packaging materials. The food packaging samples were firstly extracted by methanol-ethyl acetate, and then purified by a C18 solid-phase extraction (SPE) column. The target compounds were separated on a ZORBAX SB-C18 column (250 mm x 4.6 mm, 5 microm) in gradient elution mode using methanol and water as mobile phases. The detection wavelength was at 310 nm. The linear plots of the nine ultraviolet stabilizers were obtained between 0.2 and 10 mg/L, with the correlation coefficients of above 0. 999 for the nine ultraviolet stabilizers. The limits of detection for this method were in the range from 0.05 to 0.1 mg/L. The recoveries spiked in commercial food plastic packaging materials were in the range of 70.2% - 89.0% with the relative standard deviations of 0.4% - 4.5%. The results indicated that the method is simple, accurate, and suitable for the simultaneous determination of the nine ultraviolet stabilizers in food plastic packaging materials.
A Novel Method to Decontaminate Surgical Instruments for Operational and Austere Environments.
Knox, Randy W; Demons, Samandra T; Cunningham, Cord W
2015-12-01
The purpose of this investigation was to test a field-expedient, cost-effective method to decontaminate, sterilize, and package surgical instruments in an operational (combat) or austere environment using chlorhexidine sponges, ultraviolet C (UVC) light, and commercially available vacuum sealing. This was a bench study of 4 experimental groups and 1 control group of 120 surgical instruments. Experimental groups were inoculated with a 10(6) concentration of common wound bacteria. The control group was vacuum sealed without inoculum. Groups 1, 2, and 3 were first scrubbed with a chlorhexidine sponge, rinsed, and dried. Group 1 was then packaged; group 2 was irradiated with UVC light, then packaged; group 3 was packaged, then irradiated with UVC light through the bag; and group 4 was packaged without chlorhexidine scrubbing or UVC irradiation. The UVC was not tested by itself, as it does not grossly clean. The instruments were stored overnight and tested for remaining colony forming units (CFU). Data analysis was conducted using analysis of variance and group comparisons using the Tukey method. Group 4 CFU was statistically greater (P < .001) than the control group and groups 1 through 3. There was no statistically significant difference between the control group and groups 1 through 3. Vacuum sealing of chlorhexidine-scrubbed contaminated instruments with and without handheld UVC irradiation appears to be an acceptable method of field decontamination. Chlorhexidine scrubbing alone achieved a 99.9% reduction in CFU, whereas adding UVC before packaging achieved sterilization or 100% reduction in CFU, and UVC through the bag achieved disinfection. Published by Elsevier Inc.
Zheng, Chunmiao; Hill, Mary Catherine; Hsieh, Paul A.
2001-01-01
MODFLOW-2000, the newest version of MODFLOW, is a computer program that numerically solves the three-dimensional ground-water flow equation for a porous medium using a finite-difference method. MT3DMS, the successor to MT3D, is a computer program for modeling multi-species solute transport in three-dimensional ground-water systems using multiple solution techniques, including the finite-difference method, the method of characteristics (MOC), and the total-variation-diminishing (TVD) method. This report documents a new version of the Link-MT3DMS Package, which enables MODFLOW-2000 to produce the information needed by MT3DMS, and also discusses new visualization software for MT3DMS. Unlike the Link-MT3D Packages that coordinated previous versions of MODFLOW and MT3D, the new Link-MT3DMS Package requires an input file that, among other things, provides enhanced support for additional MODFLOW sink/source packages and allows list-directed (free) format for the flow model produced flow-transport link file. The report contains four parts: (a) documentation of the Link-MT3DMS Package Version 6 for MODFLOW-2000; (b) discussion of several issues related to simulation setup and input data preparation for running MT3DMS with MODFLOW-2000; (c) description of two test example problems, with comparison to results obtained using another MODFLOW-based transport program; and (d) overview of post-simulation visualization and animation using the U.S. Geological Survey?s Model Viewer.
Delidding and resealing hybrid microelectronic packages
NASA Astrophysics Data System (ADS)
Luce, W. F.
1982-05-01
The objective of this single phase MM and T contract was to develop the manufacturing technology necessary for the precision removal (delidding) and replacement (resealing) of covers on hermetically sealed hybrid microelectronic packages. The equipment and processes developed provide a rework technique which does not degrade the reliability of the package of the enclosed circuitry. A qualification test was conducted on 88 functional hybrid packages, with excellent results. A petition will be filed, accompanied by this report, requesting Mil-M-38510 be amended to allow this rework method.
A low cost hermetic packaging for high power industry fiber lasers
NASA Astrophysics Data System (ADS)
Ding, Jianwu; Liu, Jinhui
2018-02-01
For water-cooled fiber lasers, humidity and the resulting water-condensation has always been the biggest threat for laser reliability or power degradation, especially when used in harsh industrial environment. Here we present an innovative fiber laser packaging method featuring cast aluminum frame and an almost screw-free exterior packaging. A CW fiber laser with 1.5KW laser output power in such a compact and light-weight package has been demonstrated with an excellent beam quality and power stability for industry applications.
NASA Astrophysics Data System (ADS)
Zhang, Yumin; Zhu, Lianqing; Luo, Fei; Dong, Mingli; Ding, Xiangdong; He, Wei
2016-06-01
A metallic packaging technique of fiber Bragg grating (FBG) sensors is developed for measurement of strain and temperature, and it can be simply achieved via one-step ultrasonic welding. The average strain transfer rate of the metal-packaged sensor is theoretically evaluated by a proposed model aiming at surface-bonded metallic packaging FBG. According to analytical results, the metallic packaging shows higher average strain transfer rate compared with traditional adhesive packaging under the same packaging conditions. Strain tests are performed on an elaborate uniform strength beam for both tensile and compressive strains; strain sensitivities of approximately 1.16 and 1.30 pm/μɛ are obtained for the tensile and compressive situations, respectively. Temperature rising and cooling tests are also executed from 50°C to 200°C, and the sensitivity of temperature is 36.59 pm/°C. All the measurements of strain and temperature exhibit good linearity and stability. These results demonstrate that the metal-packaged sensors can be successfully fabricated by one-step welding technique and provide great promise for long-term and high-precision structural health monitoring.
Raval, A H; Solanki, S C; Yadav, Rajvir
2013-04-01
A simple analytical heat flow model for a closed rectangular food package containing fruits or vegetables is proposed for predicting time temperature distribution during transient cooling in a controlled environment cold room. It is based on the assumption of only conductive heat transfer inside a closed food package with effective thermal properties, and convective and radiative heat transfer at the outside of the package. The effective thermal conductivity of the food package is determined by evaluating its effective thermal resistance to heat conduction in the packages. Food packages both as an infinite slab and a finite slab have been investigated. The finite slab solution has been obtained as the product of three infinite slab solutions describe in ASHRAE guide and data book. Time temperature variation has been determined and is presented graphically. The cooling rate and the half cooling time were also obtained. These predicted values, are compared with the experimentally measured values for both the finite and infinite closed packages containing oranges. An excellent agreement between them validated the simple proposed model.
Use of modified atmosphere packaging to preserve mushroom quality during storage.
Palacios, Irene; Moro, Carlos; Lozano, Miguel; D'Arrigo, Matilde; Guillamón, Eva; García-Lafuente, Ana; Villares, Ana
2011-09-01
Mushrooms have attracted much attention due to their excellent nutritional and sensory properties. However, they are highly perishable and rapidly lose their organoleptic characteristics. Many methods have been employed for mushroom storage, such as packaging, blanching, canning, or freeze drying. Among them, modified atmosphere packaging (MAP) has been widely employed for preserving fresh mushrooms. MAP provides an affordable packaging system that partly avoids enzymatic browning, fermentation and other biochemical processes by maintaining a controlled gas atmosphere. Several factors, including optimum CO2 and O2 partial pressures, permeability, package material, thickness, or product weight, must be considered in order to design a suitable modified atmosphere package for mushrooms. Thus, different strategies are available to preserve mushroom quality after harvest. The article presents some promising patents on use of modified atmosphere packaging to preserve mushroom quality during storage.
A Framework for the Flexible Content Packaging of Learning Objects and Learning Designs
ERIC Educational Resources Information Center
Lukasiak, Jason; Agostinho, Shirley; Burnett, Ian; Drury, Gerrard; Goodes, Jason; Bennett, Sue; Lockyer, Lori; Harper, Barry
2004-01-01
This paper presents a platform-independent method for packaging learning objects and learning designs. The method, entitled a Smart Learning Design Framework, is based on the MPEG-21 standard, and uses IEEE Learning Object Metadata (LOM) to provide bibliographic, technical, and pedagogical descriptors for the retrieval and description of learning…
Bhatia, Sugandha; Bharti, Anoop
2015-06-01
The pleothera of micro organisms obtained from contaminated food cultured in a starch broth was effectively tested against antibacterial agents, i.e. nisin, lysozyme and chelating agent EDTA. A variety of combination treatments of these antimicrobial agents and their incorporation in Starch based active packaging film according to their permissibility standards was done. 4 variables of Nisin concentration (ranging from 0 to 750 IU/ml), 3 variables of lysozyme concentration (ranging from 0 to 500 IU/ml) and 3 variables of EDTA concentration from (0 to 20 μM) were chosen. Bacterial inhibition by combination of different levels of different factors without antimicrobial films was evaluated using a liquid incubation method. The samples were assayed for turbidity at interval of 2, 4 and 24 h to check effectiveness of combined effects of antimicrobial agents which proved a transitory bactericidal effect for short incubation times. Zone of Inhibition was observed in the antimicrobial films prepared by agar diffusion method. Statistical analysis of experimental data for their antimicrobial spectrum was carried out by multi regression analysis and ANOVA using Design-Expert software to plot the final equation in terms of coded factors as antimicrobial agents. The experimental data indicated that the model was highly significant. Results were also evaluated graphically using response surface showing interactions between two factors, keeping other factor fixed at values at the center of domain. Synergy was also determined among antibacterial agents using the fractional inhibitory concentration (FIC) index which was observed to be 0.56 supporting the hypothesis that nisin and EDTA function as partial synergistically. The presented work aimed to screen in quick fashion the combinatorial effect of three antimicrobial agents and evaluating their efficacy in anti microbial film development.
Motlagh, N Valipoor; Mosavian, M T Hamed; Mortazavi, S A; Tamizi, A
2012-01-01
In this research, the effects of low-density polyethylene (LDPE) packages containing micrometer-sized silver particles (LDPE-Ag) on microbial and sensory factors of dried barberry were investigated in comparison with the pure LDPE packages. LDPE-Ag packages with 1% and 2% concentrations of silver particles statistically caused a decrease in the microbial growth of barberry, especially in the case of mold and total bacteria count, compared with the pure LDPE packages. The taste, aroma, appearance, and total acceptance were evaluated by trained panelists using the 9-point hedonic scale. This test showed improvement of all these factors in the samples related to packages containing 1% and 2% concentrations of silver particles in comparison with other samples. Low-density polyethylene package containing micrometer-sized silver particles had beneficial effects on the sensory and microbial quality of barberry when compared with normal packing material. © 2011 Institute of Food Technologists®
Investigation of low cost, high reliability sealing techniques for hybrid microcircuits, phase 1
NASA Technical Reports Server (NTRS)
Perkins, K. L.; Licari, J. J.
1976-01-01
A preliminary investigation was made to determine the feasibility of using adhesive package sealing for hybrid microcircuits. Major effort consisted of: (1) surveying representative hybrid manufacturers to assess the current use of adhesives for package sealing; (2) making a cost comparison of metallurgical versus adhesive package sealing; (3) determining the seal integrity of gold plated flatpack type packages sealed with selected adhesives, thermal shock, temperature cycling, mechanical shock, and constant acceleration test environments; and (4) defining a more comprehensive study to continue the evaluation of adhesives for package sealing. Results showed that 1.27 cm square gold plated flatpack type packages sealed with the film adhesives and the paste adhesive retained their seal integrity after all tests, and that similarly prepared 2.54 cm square packages retained their seal integrity after all tests except the 10,000 g's constant acceleration test. It is concluded that these results are encouraging, but by no means sufficient to establish the suitability of adhesives for sealing high reliability hybrid microcircuits.
Reliability evaluation of hermetic dual in-line flat microcircuit packages
NASA Technical Reports Server (NTRS)
Johnson, G. M.; Conaway, L. K.
1977-01-01
The relative strengths and weaknesses of 35 commonly used hermetic flat and dual in-line packages were determined and used to rank each of the packages according to a numerical weighting scheme for package attributes. The list of attributes included desirable features in five major areas: lead and lead seal, body construction, body materials, lid and lid seal, and marking. The metal flat pack and multilayer integral ceramic flat pack and DIP received the highest rankings, and the soft glass Cerdip and Cerpak types received the lowest rankings. Loss of package hermeticity due to lead and lid seal problems was found to be the predominant failure mode from the literature/data search. However, environmental test results showed that lead and lid seal failures due to thermal stressing was only a problem with the hard glass (Ceramic) body DIP utilizing a metal lid and/or bottom. Insufficient failure data were generated for the other package types tested to correlate test results with the package ranking.
Space Shuttle/TDRSS communication and tracking systems analysis
NASA Astrophysics Data System (ADS)
Lindsey, W. C.; Chie, C. M.; Cideciyan, R.; Dessouky, K.; Su, Y. T.; Tsang, C. S.
1986-04-01
In order to evaluate the technical and operational problem areas and provide a recommendation, the enhancements to the Tracking and Data Delay Satellite System (TDRSS) and Shuttle must be evaluated through simulation and analysis. These enhancement techniques must first be characterized, then modeled mathematically, and finally updated into LinCsim (analytical simulation package). The LinCsim package can then be used as an evaluation tool. Three areas of potential enhancements were identified: shuttle payload accommodations, TDRSS SSA and KSA services, and shuttle tracking system and navigation sensors. Recommendations for each area were discussed.
Space Shuttle/TDRSS communication and tracking systems analysis
NASA Technical Reports Server (NTRS)
Lindsey, W. C.; Chie, C. M.; Cideciyan, R.; Dessouky, K.; Su, Y. T.; Tsang, C. S.
1986-01-01
In order to evaluate the technical and operational problem areas and provide a recommendation, the enhancements to the Tracking and Data Delay Satellite System (TDRSS) and Shuttle must be evaluated through simulation and analysis. These enhancement techniques must first be characterized, then modeled mathematically, and finally updated into LinCsim (analytical simulation package). The LinCsim package can then be used as an evaluation tool. Three areas of potential enhancements were identified: shuttle payload accommodations, TDRSS SSA and KSA services, and shuttle tracking system and navigation sensors. Recommendations for each area were discussed.
Rotolo, Federico; Paoletti, Xavier; Michiels, Stefan
2018-03-01
Surrogate endpoints are attractive for use in clinical trials instead of well-established endpoints because of practical convenience. To validate a surrogate endpoint, two important measures can be estimated in a meta-analytic context when individual patient data are available: the R indiv 2 or the Kendall's τ at the individual level, and the R trial 2 at the trial level. We aimed at providing an R implementation of classical and well-established as well as more recent statistical methods for surrogacy assessment with failure time endpoints. We also intended incorporating utilities for model checking and visualization and data generating methods described in the literature to date. In the case of failure time endpoints, the classical approach is based on two steps. First, a Kendall's τ is estimated as measure of individual level surrogacy using a copula model. Then, the R trial 2 is computed via a linear regression of the estimated treatment effects; at this second step, the estimation uncertainty can be accounted for via measurement-error model or via weights. In addition to the classical approach, we recently developed an approach based on bivariate auxiliary Poisson models with individual random effects to measure the Kendall's τ and treatment-by-trial interactions to measure the R trial 2 . The most common data simulation models described in the literature are based on: copula models, mixed proportional hazard models, and mixture of half-normal and exponential random variables. The R package surrosurv implements the classical two-step method with Clayton, Plackett, and Hougaard copulas. It also allows to optionally adjusting the second-step linear regression for measurement-error. The mixed Poisson approach is implemented with different reduced models in addition to the full model. We present the package functions for estimating the surrogacy models, for checking their convergence, for performing leave-one-trial-out cross-validation, and for plotting the results. We illustrate their use in practice on individual patient data from a meta-analysis of 4069 patients with advanced gastric cancer from 20 trials of chemotherapy. The surrosurv package provides an R implementation of classical and recent statistical methods for surrogacy assessment of failure time endpoints. Flexible simulation functions are available to generate data according to the methods described in the literature. Copyright © 2017 Elsevier B.V. All rights reserved.
Flexible packaging for microelectronic devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, Benjamin John; Nielson, Gregory N.; Cruz-Campa, Jose Luis
An apparatus, method, and system, the apparatus and system including a flexible microsystems enabled microelectronic device package including a microelectronic device positioned on a substrate; an encapsulation layer encapsulating the microelectronic device and the substrate; a protective layer positioned around the encapsulating layer; and a reinforcing layer coupled to the protective layer, wherein the substrate, encapsulation layer, protective layer and reinforcing layer form a flexible and optically transparent package around the microelectronic device. The method including encapsulating a microelectronic device positioned on a substrate within an encapsulation layer; sealing the encapsulated microelectronic device within a protective layer; and coupling themore » protective layer to a reinforcing layer, wherein the substrate, encapsulation layer, protective layer and reinforcing layer form a flexible and optically transparent package around the microelectronic device.« less
ExGUtils: A Python Package for Statistical Analysis With the ex-Gaussian Probability Density.
Moret-Tatay, Carmen; Gamermann, Daniel; Navarro-Pardo, Esperanza; Fernández de Córdoba Castellá, Pedro
2018-01-01
The study of reaction times and their underlying cognitive processes is an important field in Psychology. Reaction times are often modeled through the ex-Gaussian distribution, because it provides a good fit to multiple empirical data. The complexity of this distribution makes the use of computational tools an essential element. Therefore, there is a strong need for efficient and versatile computational tools for the research in this area. In this manuscript we discuss some mathematical details of the ex-Gaussian distribution and apply the ExGUtils package, a set of functions and numerical tools, programmed for python, developed for numerical analysis of data involving the ex-Gaussian probability density. In order to validate the package, we present an extensive analysis of fits obtained with it, discuss advantages and differences between the least squares and maximum likelihood methods and quantitatively evaluate the goodness of the obtained fits (which is usually an overlooked point in most literature in the area). The analysis done allows one to identify outliers in the empirical datasets and criteriously determine if there is a need for data trimming and at which points it should be done.
ExGUtils: A Python Package for Statistical Analysis With the ex-Gaussian Probability Density
Moret-Tatay, Carmen; Gamermann, Daniel; Navarro-Pardo, Esperanza; Fernández de Córdoba Castellá, Pedro
2018-01-01
The study of reaction times and their underlying cognitive processes is an important field in Psychology. Reaction times are often modeled through the ex-Gaussian distribution, because it provides a good fit to multiple empirical data. The complexity of this distribution makes the use of computational tools an essential element. Therefore, there is a strong need for efficient and versatile computational tools for the research in this area. In this manuscript we discuss some mathematical details of the ex-Gaussian distribution and apply the ExGUtils package, a set of functions and numerical tools, programmed for python, developed for numerical analysis of data involving the ex-Gaussian probability density. In order to validate the package, we present an extensive analysis of fits obtained with it, discuss advantages and differences between the least squares and maximum likelihood methods and quantitatively evaluate the goodness of the obtained fits (which is usually an overlooked point in most literature in the area). The analysis done allows one to identify outliers in the empirical datasets and criteriously determine if there is a need for data trimming and at which points it should be done. PMID:29765345