Test development for the thermionic system evaluation test (TSET) project
NASA Astrophysics Data System (ADS)
Morris, D. Brent; Standley, Vaughn H.; Schuller, Michael J.
1992-01-01
The arrival of a Soviet TOPAZ-II space nuclear reactor affords the US space nuclear power (SNP) community the opportunity to study an assembled thermionic conversion power system. The TOPAZ-II will be studied via the Thermionic System Evaluation Test (TSET) Project. This paper is devoted to the discussion of TSET test development as related to the objectives contained in the TSET Project Plan (Standley et al. 1991). The objectives contained in the Project Plan are the foundation for scheduled TSET tests on TOPAZ-II and are derived from the needs of the Air Force Thermionic SNP program. Our ability to meet the objectives is bounded by unique constraints, such as procurement requirements, operational limitations, and necessary interaction between US and Soviet Scientists and engineers. The fulfillment of the test objectives involves a thorough methodology of test scheduling and data managment. The overall goals for the TSET program are gaining technical understanding of a thermionic SNP system and demonstrating the capabilities and limitations of such a system while assisting in the training of US scientist and engineers in preparation for US SNP system testing. Tests presently scheduled as part of TSET include setup, demonstration, and verification tests; normal and off-normal operating test, and system and component performance tests.
Thermionic system evaluated test (TSET) facility description
NASA Astrophysics Data System (ADS)
Fairchild, Jerry F.; Koonmen, James P.; Thome, Frank V.
1992-01-01
A consortium of US agencies are involved in the Thermionic System Evaluation Test (TSET) which is being supported by the Strategic Defense Initiative Organization (SDIO). The project is a ground test of an unfueled Soviet TOPAZ-II in-core thermionic space reactor powered by electrical heat. It is part of the United States' national thermionic space nuclear power program. It will be tested in Albuquerque, New Mexico at the New Mexico Engineering Research Institute complex by the Phillips Laboratoty, Sandia National Laboratories, Los Alamos National Laboratory, and the University of New Mexico. One of TSET's many objectives is to demonstrate that the US can operate and test a complete space nuclear power system, in the electrical heater configuration, at a low cost. Great efforts have been made to help reduce facility costs during the first phase of this project. These costs include structural, mechanical, and electrical modifications to the existing facility as well as the installation of additional emergency systems to mitigate the effects of utility power losses and alkali metal fires.
Cherenkov imaging for Total Skin Electron Therapy (TSET)
NASA Astrophysics Data System (ADS)
Xie, Yunhe; Petroccia, Heather; Maity, Amit; Miao, Tianshun; Zhu, Yihua; Bruza, Petr; Pogue, Brian W.; Andreozzi, Jacqueline M.; Plastaras, John P.; Dong, Lei; Zhu, Timothy C.
2018-03-01
Total Skin Electron Therapy (TSET) utilizes high-energy electrons to treat cancers on the entire body surface. The otherwise invisible radiation beam can be observed via the optical Cherenkov photons emitted from interaction between the high-energy electron beam and tissue. Using a specialized camera-system, the Cherenkov emission can thus be used to evaluate the dose uniformity on the surface of the patient in real-time. Each patient was also monitored during TSET via in-vivo detectors (IVD) in nine locations. Patients undergoing TSET in various conditions (whole body and half body) were imaged and analyzed, and the viability of the system to provide clinical feedback was established.
On the use of unshielded cables in ionization chamber dosimetry for total-skin electron therapy.
Chen, Z; Agostinelli, A; Nath, R
1998-03-01
The dosimetry of total-skin electron therapy (TSET) usually requires ionization chamber measurements in a large electron beam (up to 120 cm x 200 cm). Exposing the chamber's electric cable, its connector and part of the extension cable to the large electron beam will introduce unwanted electronic signals that may lead to inaccurate dosimetry results. While the best strategy to minimize the cable-induced electronic signal is to shield the cables and its connector from the primary electrons, as has been recommended by the AAPM Task Group Report 23 on TSET, cables without additional shielding are often used in TSET dosimetry measurements for logistic reasons, for example when an automatic scanning dosimetry is used. This paper systematically investigates the consequences and the acceptability of using an unshielded cable in ionization chamber dosimetry in a large TSET electron beam. In this paper, we separate cable-induced signals into two types. The type-I signal includes all charges induced which do not change sign upon switching the chamber polarity, and type II includes all those that do. The type-I signal is easily cancelled by the polarity averaging method. The type-II cable-induced signal is independent of the depth of the chamber in a phantom and its magnitude relative to the true signal determines the acceptability of a cable for use under unshielded conditions. Three different cables were evaluated in two different TSET beams in this investigation. For dosimetry near the depth of maximum buildup, the cable-induced dosimetry error was found to be less than 0.2% when the two-polarity averaging technique was applied. At greater depths, the relative dosimetry error was found to increase at a rate approximately equal to the inverse of the electron depth dose. Since the application of the two-polarity averaging technique requires a constant-irradiation condition, it was demonstrated than an additional error of up to 4% could be introduced if the unshielded cable's spatial configuration were altered during the two-polarity measurements. This suggests that automatic scanning systems with unshielded cables should not be used in TSET ionization chamber dosimetry. However, the data did show that an unshielded cable may be used in TSET ionization chamber dosimetry if the size of cable-induced error in a given TSET beam is pre-evaluated and the measurement is carefully conducted. When such an evaluation has not been performed, additional shielding should be applied to the cable being used, making measurements at multiple points difficult.
Rowe, John W; Converse, Paul E; Clark, David L
2014-02-01
The capacity for an ectothermic reptile to thermoregulate has implications for many components of its life history. Over two years, we studied thermoregulation in a population of Midland painted turtles (Chrysemys picta marginata) in a shallow, thermally variable wetland during summer in Northern Michigan. Mean body temperature (Tb) of free-ranging turtles was greater in 2008 (25.8 °C) than in 2010 (19.7 °C). Laboratory determined thermoregulatory set point (Tset) ranged from 25 °C (Tset-min) to 31 °C (Tset-max) and was lower during the fall (17-26 °C). Deviations of Tb distributions from field measured operative temperatures (Te) and indices of thermoregulation indicated that C. picta marginata were capable of a limited degree of thermoregulation. Operative temperatures and thermal quality (de=|Tset-min-Te| and |Te-Tset-max|) cycled daily with maximal thermal quality occurring during late morning and late afternoon. The accuracy of thermoregulation (db=|Tset-min-Tb| and |Tb-Tset-max|) was maximal (db values were minimal) as Tb declined and traversed Tset during the late afternoon-early evening hours and was higher on cloudy days than on sunny days because relatively low Te values decreased the number of Tb values that were above Tset. Our index of thermal exploitation (Ex=frequency of Tb observations within Tset) was 36%, slightly lower than that reported for an Ontario population of C. picta marginata. Regression of db (thermal accuracy) on de (thermal quality) indicated that turtles invested more in thermoregulation when thermal quality was low and when water levels were high than when they were low. There were no intersexual differences in mean Tb throughout the year but females had relatively high laboratory determined Tb values in the fall, perhaps reflecting the importance of maintaining ovarian development prior to winter. Copyright © 2013 Elsevier Ltd. All rights reserved.
Weideman, Yvonne L; Young, Lisa; Lockhart, Joan Such; Grund, Faye J; Fridline, Mark M; Panas, Marie
2016-01-01
The purpose of this project was to design, implement, and evaluate a virtual simulation experience (VSE) facilitating student access to diverse cultures and strengthening their ability to provide culturally congruent care. Faculty from two universities collaborated in designing a pre/postnatal VSE with African American and Amish patients. Students viewed patient assessments, interacted with patients, worked in teams to develop culturally appropriate care plans, and engaged in debriefing. Outcomes measurements included Jeffreys' Transcultural Self-Efficacy Test (TSET), researcher developed care plans, and program evaluation. Over 80% (N=141) of the invited students consented. Significant increases occurred in overall and subscale post-TSET scores (P<.001). Care plan mean scores were ≥8.82 out of 10 points per category. Students recognized the need to be nonjudgmental in patient care. This study suggests that VSEs are effective in transcending geographic barriers, gaining access to diverse cultures, and strengthening students' cultural competence. Copyright © 2016 Elsevier Inc. All rights reserved.
Application of a Systems Engineering Approach to Support Space Reactor Development
NASA Astrophysics Data System (ADS)
Wold, Scott
2005-02-01
In 1992, approximately 25 Russian and 12 U.S. engineers and technicians were involved in the transport, assembly, inspection, and testing of over 90 tons of Russian equipment associated with the Thermionic System Evaluation Test (TSET) Facility. The entire Russian Baikal Test Stand, consisting of a 5.79 m tall vacuum chamber and related support equipment, was reassembled and tested at the TSET facility in less than four months. In November 1992, the first non-nuclear operational test of a complete thermionic power reactor system in the U.S. was accomplished three months ahead of schedule and under budget. A major factor in this accomplishment was the application of a disciplined top-down systems engineering approach and application of a spiral development model to achieve the desired objectives of the TOPAZ International Program (TIP). Systems Engineering is a structured discipline that helps programs and projects conceive, develop, integrate, test and deliver products and services that meet customer requirements within cost and schedule. This paper discusses the impact of Systems Engineering and a spiral development model on the success of the TOPAZ International Program and how the application of a similar approach could help ensure the success of future space reactor development projects.
Perceived Transcultural Self-Efficacy of Nurses in General Hospitals in Guangzhou, China
Li, Juan; He, Zhuang; Luo, Yong; Zhang, Rong
2016-01-01
Background Conflicts arising from cultural diversity among patients and hospital staff in China have become intense. Hospitals have an urgent need to improve transcultural self-efficacy of nurses for providing effective transcultural nursing. Objective The purpose of the research was to (a) evaluate the current status of perceived transcultural self-efficacy of nurses in general hospitals in Guangzhou, China; (b) explore associations between demographic characteristics of nurses and their perceived transcultural self-efficacy; and (c) assess the reliability and validity of scores on the Chinese version of the Transcultural Self-Efficacy Tool (TSET). Methods A cross-sectional survey of registered nurses from three general hospitals was conducted. Quota and convenience sampling were used. Participants provided demographic information and answered questions on the TSET. Results A total of 1,156 registered nurses took part. Most nurses had a moderate level of self-efficacy on the Cognitive (87.9%), Practical (87%), and Affective (89.2%) TSET subscales. Nurses who were older; who had more years of work experience, higher professional titles, higher incomes, and a minority background; and who were officially employed (not temporary positions) had higher perceived transcultural self-efficacy. Reliability estimated using Cronbach’s alpha was .99 for the total TSET score; reliability for the three subscales ranged from .97 to .98. Confirmatory factor analysis of TSET scores showed good fit with a three-factor model. Conclusion The results of this study can provide insights and guidelines for hospital nursing management to facilitate design of in-service education systems to improve transcultural self-efficacy of nurses. PMID:27454552
Lorioux, Sophie; DeNardo, Dale F; Gorelick, Root; Lourdais, Olivier
2012-04-15
Embryonic life is particularly sensitive to its surroundings, and the developmental environment can have long-lasting effects on offspring. In oviparous species, the impacts of the developmental environment on offspring traits are mostly examined during development within the egg. However, as more than 25% of the development of squamate reptiles can occur prior to oviposition, we explored the effect of thermal conditions on development prior to oviposition in an oviparous snake species, the Children's python (Antaresia childreni). We housed gravid female pythons under three thermal cycles: an optimal regime that reflected maternal preference in a non-constrained environment (constant preferred body temperature of gravid females, T(set)=31.5°C) and two mildly suboptimal regimes that shared the same mean temperature of 27.7°C, but differed in the duration at T(set). In one of the constraining regimes, females had access to T(set) for 4 h daily whereas in the other regime, females never reached T(set) (maximal temperature of 29.0°C). Thermal treatments were maintained throughout gravidity in all three groups, but, after oviposition, all eggs were incubated at T(set) until hatching. Compared with the optimal regime, the two suboptimal regimes had a longer duration of gravidity, which resulted in delayed hatching. Between the two suboptimal regimes, gravidity was significantly shorter in the treatment that included time at T(set). Furthermore, suboptimal regimes influenced offspring traits at hatching, including body morphology, antipredator behavior, strength and metabolism. However, partial access to maternal T(set) significantly enhanced several offspring traits, including performance. Our results demonstrate the importance of time at T(set) on early development and suggest an adaptive significance of maternal thermoregulation prior to oviposition.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cui, G; Ha, J; Zhou, S
Purpose: To examine and validate the absolute dose for total skin electron therapy (TSET) through an end-to-end test with a Rando phantom using optically stimulated luminescent dosimeters (OSLDs) and EBT3 radiochromic films. Methods: A Varian Trilogy linear accelerator equipped with the special procedure 6 MeV HDTSe- was used to perform TSET irradiations using a modified Stanford 6-dual-field technique. The absolute dose was calibrated using a Markus ion chamber at a reference depth of 1.3cm at 100 cm SSD with a field size of 36 × 36 cm at the isocenter in solid water slabs. The absolute dose was cross validatedmore » by a farmer ion chamber. Then the dose rate in the unit of cGy/Mu was calibrated using the Markus chamber at the treatment position. OSLDs were used to independently verify the dose using the calibrated dose rate. Finally, a patient treatment plan (200 cGy/cycle) was delivered in the QA mode to a Rando phantom, which had 16 pairs of OSLDs and EBT3 films taped onto its surface at different anatomical positions. The doses recorded were read out to validate the absolute dosimetry for TSET. Results: The OSLD measurements were within 7% agreement with the planned dose except the shoulder areas, where the doses recorded were 23% lower on average than those of the planned. The EBT3 film measurements were within 10% agreement with the planned dose except the shoulder and the scalp vertex areas, where the respective doses recorded were 18% and 14% lower on average than those of the planned. The OSLDs gave more consistent dose measurements than those of the EBT3 films. Conclusion: The absolute dosimetry for TSET was validated by an end-to-end test with a Rando phantom using the OSLDs and EBT3 films. The beam calibration and monitor unit calculations were confirmed.« less
Multidisciplinary analysis and design of printed wiring boards
NASA Astrophysics Data System (ADS)
Fulton, Robert E.; Hughes, Joseph L.; Scott, Waymond R., Jr.; Umeagukwu, Charles; Yeh, Chao-Pin
1991-04-01
Modern printed wiring board design depends on electronic prototyping using computer-based simulation and design tools. Existing electrical computer-aided design (ECAD) tools emphasize circuit connectivity with only rudimentary analysis capabilities. This paper describes a prototype integrated PWB design environment denoted Thermal Structural Electromagnetic Testability (TSET) being developed at Georgia Tech in collaboration with companies in the electronics industry. TSET provides design guidance based on enhanced electrical and mechanical CAD capabilities including electromagnetic modeling testability analysis thermal management and solid mechanics analysis. TSET development is based on a strong analytical and theoretical science base and incorporates an integrated information framework and a common database design based on a systematic structured methodology.
Remick, Kyle N; Wong, Evan G; Chuot Chep, Chep; Morton, Richard T; Monsour, Abdullah; Fisher, Dane; Oh, John S; Wilson, Ramey; Malone, Debra L; Branas, Charles; Elster, Eric; Gross, Kirby R; Kushner, Adam L
2014-11-01
Trauma remains a leading cause of death and disability in the world, and trauma systems decrease mortality from trauma. We developed the Global Trauma System Evaluation Tool (G-TSET) specifically for use in low- and middle-income countries (LMICs). The Sudan People's Liberation Army (SPLA) in the Republic of South Sudan (RSS) desires a military trauma system (MTS) which allowed us to pilot the G-TSET. The G-TSET was developed by modifying key components of a trauma system applicable to LMICs. We partnered with the SPLA Medical Corps using clinical collaboration, direct observation, and discussion groups. Benchmarks and indicators were scored with 5 indicating "full capability" and 1 meaning "not present" and were used to develop a SPLA MTS plan. The overall MTS score was 1.15 indicating an urgent need for system development. The assessment highlighted the need for SPLA Command support. Battlefield care, transport to a trauma facility, and inter-facility communication were identified for improvement. After essential battlefield care, consisting primarily of bandaging and splinting, transport times for injured SPLA soldiers were 12h to 3 days by truck. Based on our findings, we collaborated with SPLA medical leadership to develop a plan to develop a formal MTS. We piloted a novel trauma system assessment tool for the MTS in the RSS. Qualitatively, we identified gaps in the MTS and provided the medical leadership with a plan for improvement. We anticipate a short-term follow-up to quantify improvement, and we seek to validate this tool for use in other countries. Published by Elsevier Ltd.
Zhang, Rongxiao; Gladstone, David J.; Williams, Benjamin B.; Glaser, Adam K.; Pogue, Brian W.; Jarvis, Lesley A.
2016-01-01
Purpose: A method was developed utilizing Cherenkov imaging for rapid and thorough determination of the two gantry angles that produce the most uniform treatment plane during dual-field total skin electron beam therapy (TSET). Methods: Cherenkov imaging was implemented to gather 2D measurements of relative surface dose from 6 MeV electron beams on a white polyethylene sheet. An intensified charge-coupled device camera time-gated to the Linac was used for Cherenkov emission imaging at sixty-two different gantry angles (1° increments, from 239.5° to 300.5°). Following a modified Stanford TSET technique, which uses two fields per patient position for full body coverage, composite images were created as the sum of two beam images on the sheet; each angle pair was evaluated for minimum variation across the patient region of interest. Cherenkov versus dose correlation was verified with ionization chamber measurements. The process was repeated at source to surface distance (SSD) = 441, 370.5, and 300 cm to determine optimal angle spread for varying room geometries. In addition, three patients receiving TSET using a modified Stanford six-dual field technique with 6 MeV electron beams at SSD = 441 cm were imaged during treatment. Results: As in previous studies, Cherenkov intensity was shown to directly correlate with dose for homogenous flat phantoms (R2 = 0.93), making Cherenkov imaging an appropriate candidate to assess and optimize TSET setup geometry. This method provided dense 2D images allowing 1891 possible treatment geometries to be comprehensively analyzed from one data set of 62 single images. Gantry angles historically used for TSET at their institution were 255.5° and 284.5° at SSD = 441 cm; however, the angles optimized for maximum homogeneity were found to be 252.5° and 287.5° (+6° increase in angle spread). Ionization chamber measurements confirmed improvement in dose homogeneity across the treatment field from a range of 24.4% at the initial angles, to only 9.8% with the angles optimized. A linear relationship between angle spread and SSD was observed, ranging from 35° at 441 cm, to 39° at 300 cm, with no significant variation in percent-depth dose at midline (R2 = 0.998). For patient studies, factors influencing in vivo correlation between Cherenkov intensity and measured surface dose are still being investigated. Conclusions: Cherenkov intensity correlates to relative dose measured at depth of maximum dose in a uniform, flat phantom. Imaging of phantoms can thus be used to analyze and optimize TSET treatment geometry more extensively and rapidly than thermoluminescent dosimeters or ionization chambers. This work suggests that there could be an expanded role for Cherenkov imaging as a tool to efficiently improve treatment protocols and as a potential verification tool for routine monitoring of unique patient treatments. PMID:26843259
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andreozzi, Jacqueline M., E-mail: Jacqueline.M.Andreozzi.th@dartmouth.edu, E-mail: Lesley.A.Jarvis@hitchcock.org; Glaser, Adam K.; Zhang, Rongxiao
2016-02-15
Purpose: A method was developed utilizing Cherenkov imaging for rapid and thorough determination of the two gantry angles that produce the most uniform treatment plane during dual-field total skin electron beam therapy (TSET). Methods: Cherenkov imaging was implemented to gather 2D measurements of relative surface dose from 6 MeV electron beams on a white polyethylene sheet. An intensified charge-coupled device camera time-gated to the Linac was used for Cherenkov emission imaging at sixty-two different gantry angles (1° increments, from 239.5° to 300.5°). Following a modified Stanford TSET technique, which uses two fields per patient position for full body coverage, compositemore » images were created as the sum of two beam images on the sheet; each angle pair was evaluated for minimum variation across the patient region of interest. Cherenkov versus dose correlation was verified with ionization chamber measurements. The process was repeated at source to surface distance (SSD) = 441, 370.5, and 300 cm to determine optimal angle spread for varying room geometries. In addition, three patients receiving TSET using a modified Stanford six-dual field technique with 6 MeV electron beams at SSD = 441 cm were imaged during treatment. Results: As in previous studies, Cherenkov intensity was shown to directly correlate with dose for homogenous flat phantoms (R{sup 2} = 0.93), making Cherenkov imaging an appropriate candidate to assess and optimize TSET setup geometry. This method provided dense 2D images allowing 1891 possible treatment geometries to be comprehensively analyzed from one data set of 62 single images. Gantry angles historically used for TSET at their institution were 255.5° and 284.5° at SSD = 441 cm; however, the angles optimized for maximum homogeneity were found to be 252.5° and 287.5° (+6° increase in angle spread). Ionization chamber measurements confirmed improvement in dose homogeneity across the treatment field from a range of 24.4% at the initial angles, to only 9.8% with the angles optimized. A linear relationship between angle spread and SSD was observed, ranging from 35° at 441 cm, to 39° at 300 cm, with no significant variation in percent-depth dose at midline (R{sup 2} = 0.998). For patient studies, factors influencing in vivo correlation between Cherenkov intensity and measured surface dose are still being investigated. Conclusions: Cherenkov intensity correlates to relative dose measured at depth of maximum dose in a uniform, flat phantom. Imaging of phantoms can thus be used to analyze and optimize TSET treatment geometry more extensively and rapidly than thermoluminescent dosimeters or ionization chambers. This work suggests that there could be an expanded role for Cherenkov imaging as a tool to efficiently improve treatment protocols and as a potential verification tool for routine monitoring of unique patient treatments.« less
Temporal heating profile influence on the immediate bond strength following laser tissue soldering.
Rabi, Yaron; Katzir, Abraham
2010-07-01
Bonding of tissues by laser heating is considered as a future alternative to sutures and staples. Increasing the post-operative bond strength remains a challenging issue for laser tissue bonding, especially in organs that have to sustain considerable tension or pressure. In this study, we investigated the influence of different temporal heating profiles on the strength of soldered incisions. The thermal damage following each heating procedure was quantified, in order to assess the effect of each heating profile on the thermal damage. Incisions in porcine bowel tissue strips (1 cmx4 cm) were soldered, using a 44% liquid albumin mixed with indocyanine green and a temperature controlled laser (830 nm) tissue bonding system. Heating was done either with a linear or a step temporal heating profile. The incisions were bonded by soldering at three points, separated by 2 mm. Set-point temperatures of T(set) = 60, 70, 80, 90, 100, 110, 150 degrees C and dwell times of t(d) = 10, 20, 30, 40 seconds were investigated. The bond strength was measured immediately following each soldering by applying a gradually increased tension on the tissue edges until the bond break. Bonds formed by linear heating were stronger than the ones formed by step heating: at T(set) = 80 degrees C the bonds were 40% stronger and at T(set) = 90 degrees C the bonds strength was nearly doubled. The bond strength difference between the heating methods was larger as T(set) increased. Linear heating produced stronger bonds than step heating. The difference in the bond strength was more pronounced at high set-point temperatures and short dwell times. The bond strength could be increased with either higher set-point temperature or a longer dwell time.
NASA Astrophysics Data System (ADS)
Luchau, David W.; Sinkevich, Valery G.; Wernsman, Bernard; Mulder, Daniel M.
1996-03-01
A final report on the output power characteristics and capabilities of the TOPAZ II Space Nuclear Power Unit Ya-21u is presented. Results showed that after a total of almost 8,000 hours of system testing in the U.S. and Russia, several emergency cooldowns, and three inadvertent air introductions to the interelectrode gap (IEG) that the TOPAZ II demonstrates the potential for providing reliable power in a space environment. Output power optimizations and system characteristics following a shock and vibration test are shown. These tests were performed using electrical heaters that simulate nuclear fuel heating. This paper will focus primarily on the changes in output power characteristics over the lifetime of Ya-21u. All U.S. testing was conducted at the Thermionic System Evaluation Test (TSET) Facility of the New Mexico Engineering Research Institute (NMERI) as a part of the TOPAZ International Program (TIP). TIP is managed by the Air Force Phillips Laboratory (PL) for the Ballistic Missile Defense Organization (BMDO).
Andreozzi, Jacqueline M; Brůža, Petr; Tendler, Irwin I; Mooney, Karen E; Jarvis, Lesley A; Cammin, Jochen; Li, Harold; Pogue, Brian W; Gladstone, David J
2018-06-01
The purpose of this study was to identify the optimal treatment geometry for total skin electron therapy (TSET) using a new optimization metric from Cherenkov image analysis, and to investigate the sensitivity of the Cherenkov imaging method to floor scatter effects in this unique treatment setup. Cherenkov imaging using an intensified charge coupled device (ICCD) was employed to measure the relative surface dose distribution as a 2D image in the total skin electron treatment plane. A 1.2 m × 2.2 m × 1 cm white polyethylene sheet was placed vertically at a source to surface distance (SSD) of 300 cm, and irradiated with 6 MeV high dose rate TSET beams. The linear accelerator coordinate system used stipulates 0° is the bottom of the gantry arc, and progresses counterclockwise so that gantry angle 270° produces a horizontal beam orthogonal to the treatment plane. First, all unique pairs of treatment beams were analyzed to determine the performance of the currently recommended symmetric treatment angles (±20° from the horizontal), compared to treatment geometries unconstrained to upholding gantry angle symmetry. This was performed on two medical linear accelerators (linacs). Second, the extent of the floor scatter contributions to measured surface dose at the extended SSD required for TSET were imaged using three gantry angles of incidence: 270° (horizontal), 253° (-17°), and 240° (-30°). Images of the surface dose profile at each angle were compared to the standard concrete floor when steel plates, polyvinyl chloride (PVC), and solid water were placed on the ground at the base of the treatment plane. Postprocessing of these images allowed for comparison of floor material-based scatter profiles with previously published simulation results. Analysis of the symmetric treatment geometry (270 ± 20°) and the identified optimal treatment geometry (270 + 23° and 270 - 17°) showed a 16% increase in the 90% isodose area for the latter field pair on the first linac. The optimal asymmetric pair for the second linac (270 + 25° and 270 - 17°) provided a 52% increase in the 90% isodose area when compared to the symmetric geometry. Difference images between Cherenkov images captured with test materials (steel, PVC, and solid water) and the control (concrete floor) demonstrated relative changes in the two-dimensional (2D) dose profile over a 1 × 1.9 m region of interest (ROI) that were consistent with published simulation data. Qualitative observation of the residual images demonstrates localized increases and decreases with respect to the change in floor material and gantry angle. The most significant changes occurred when the beam was most directly impinging the floor (gantry angle 240°, horizontal -30°), where the PVC floor material decreased scatter dose by 1-3% in 7.2% of the total ROI area, and the steel plate increased scatter dose by 1-3% in 7.0% of the total ROI area. An updated Cherenkov imaging method identified asymmetric, machine-dependent TSET field angle pairs that provided much larger 90% isodose areas than the commonly adopted symmetric geometry suggested by Task Group 30 Report 23. A novel demonstration of scatter dose Cherenkov imaging in the TSET field was established. © 2018 American Association of Physicists in Medicine.
Seasonal shifts in the thermal biology of the lizard Liolaemus tandiliensis (Squamata, Liolaemidae).
Stellatelli, Oscar Aníbal; Villalba, Agustina; Block, Carolina; Vega, Laura Estela; Dajil, Juan Esteban; Cruz, Félix Benjamín
2018-04-01
Small lizards can accommodate to constraints imposed by temporal changes in ambient temperature through a combination of adaptive evolution and behavioral and physiological plasticity. Thermal physiology plasticity may compensate for climate variation and favor performance while minimizing behavioral costs in sub-optimal conditions. The Tandilia's lizard, Liolaemus tandiliensis, occurs in an isolated mountain range of the Argentinean temperate Pampas. In this study, we compared the thermal biology of L. tandiliensis between late spring (December) and mid-summer (February). The habitats' thermal quality was lower in late spring than in mid-summer. The lizard's field-body temperature (Tb) was 2-3 °C higher than the operative temperature (Te). Overall, the mean preferred temperature (Tsel) was 37.4 °C [preferred range (Tset): 36.2-38.7 °C], and was similar to other Liolaemus species. The Tset and Tsel of females in late spring were 1.8 °C lower than in mid-summer. In the case of males, the Tsel did not vary among seasons, while the Tset had a difference of 2.5 °C between seasons. Adults were moderate thermoregulators, but females were more efficient only in late spring (E males = 0.69; E females = 0.58), compared to mid-summer (E males = 0.68; E females = 0.50). Juveniles did not show temporal differences in temperature preferences and had a relatively higher efficiency in late spring (E = 0.38) compared to mid-summer (E = 0.28). An increased proportion of juveniles and adults shifted their Tb near to the Tset in late spring respect to mid-summer. The adults also matched their preferred temperatures to their current body temperature. These results suggest that seasonal shifts in the thermoregulatory parameters of L. tandiliensis may improve their thermoregulatory efficiency. Although temporal variation in ambient temperatures might influence the thermal biology of the studied lizards, other factors such as changes in the reproductive status may have also interfered. Copyright © 2018 Elsevier Ltd. All rights reserved.
Chemorheology of highly filled thermosets: Effects of fillers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Halley, P.J.
1996-12-31
Highly filled thermosets are utilised in the manufacture of many high value added products in the aerospace, communication, computer and automobile industries. A fundamental understanding of the processing of these materials has, however, been hindered by the inherent complexities of the flow and cure properties of these composite thermoset materials. A chemorheological (gel point and chemoviscosity) testing procedure is described here that uses dynamic multiwave tests on a modified Rheometrics RDSII system, using a filled epoxy moulding compound (EMC). Data from this testing procedure has been combined with physical property and kinetic data to produce realistic simulation results using flowmore » simulation software (TSET; MOLDFLOW Pty Ltd). This chemorheological testing procedure has now been successfully implemented commercially by MOLDFLOW Pty Ltd.« less
Wallon, G; Bonnet, A; Guérin, C
2013-06-01
Tidal volume (V(T)) must be accurately delivered by anaesthesia ventilators in the volume-controlled ventilation mode in order for lung protective ventilation to be effective. However, the impact of fresh gas flow (FGF) and lung mechanics on delivery of V(T) by the newest anaesthesia ventilators has not been reported. We measured delivered V(T) (V(TI)) from four anaesthesia ventilators (Aisys™, Flow-i™, Primus™, and Zeus™) on a pneumatic test lung set with three combinations of lung compliance (C, ml cm H2O(-1)) and resistance (R, cm H2O litre(-1) s(-2)): C60R5, C30R5, C60R20. For each CR, three FGF rates (0.5, 3, 10 litre min(-1)) were investigated at three set V(T)s (300, 500, 800 ml) and two values of PEEP (0 and 10 cm H2O). The volume error = [(V(TI) - V(Tset))/V(Tset)] ×100 was computed in body temperature and pressure-saturated conditions and compared using analysis of variance. For each CR and each set V(T), the absolute value of the volume error significantly declined from Aisys™ to Flow-i™, Zeus™, and Primus™. For C60R5, these values were 12.5% for Aisys™, 5% for Flow-i™ and Zeus™, and 0% for Primus™. With an increase in FGF, absolute values of the volume error increased only for Aisys™ and Zeus™. However, in C30R5, the volume error was minimal at mid-FGF for Aisys™. The results were similar at PEEP 10 cm H2O. Under experimental conditions, the volume error differed significantly between the four new anaesthesia ventilators tested and was influenced by FGF, although this effect may not be clinically relevant.
Role of MRI in Diagnosis of Ruptured Intracranial Dermoid Cyst
Muçaj, Sefedin; Ugurel, Mehmet Sahin; Dedushi, Kreshnike; Ramadani, Naser; Jerliu, Naim
2017-01-01
Introduction: Intracranial dermoid cystic tumors account for <1% of all intracranial masses. Case report: A 52-year-old male, having headaches, nausea and is presented with a history of 2 episodes of new onset seizures. On presentation, the patient had a normal physical exam, including a complete neurological and cranial nerve exam. Methods: Precontrast MRI; TSE/T2Wsequence in axial/coronal planes; 3D – HI-resolution T1W sagittal; FLAIR/T2W axial; FLAIR/T2W, Flash/T2W oblique coronal plane, GRE/T2W axial. Post-contrast TSE/T1W sequence in axial, coronal and sagittal planes. Diffusion weighted and ADC mapping, postcontrast: TSE/T1W sequence in axial, coronal and sagittal planes. Results: Subsequent MRI of the brain revealed an oval and lobulated 47x34x30mm (TRxAPxCC) non-enhancing T1-hyperintense mass in right cavernous sinus, with compression of surrounding mesial temporal lobe and right anterolateral aspect of mesencephalon. Findings are consistent with ruptured dermoid cyst, given the evacuated sebum content at its lower half. Sebum particles in millimetric sizes are seen within right Sylvian fissure, anterior horns of lateral ventricles and to a lesser extent within left Sylvian fissure, right parietal sulci, cerebral aqueduct, and basal cisterns. No restricted diffusion is seen, eliminating the possibility of epidermoid. A shunt catheter is evident traversing between right lateral ventricle and right parietal bone; besides, slit-like right lateral ventricle is noted (likely secondary to over-draining shunt catheter). Conclusion: Intracranial dermoid cysts are benign rare slow-growing tumors that upon rupture, however, widespread presence of T1 hyperintense droplets and leptomeningeal enhancement can be noted–making MRI the best imaging modality for diagnosis of this rare entity. PMID:28883682
Role of MRI in Diagnosis of Ruptured Intracranial Dermoid Cyst.
Muçaj, Sefedin; Ugurel, Mehmet Sahin; Dedushi, Kreshnike; Ramadani, Naser; Jerliu, Naim
2017-06-01
Intracranial dermoid cystic tumors account for <1% of all intracranial masses. A 52-year-old male, having headaches, nausea and is presented with a history of 2 episodes of new onset seizures. On presentation, the patient had a normal physical exam, including a complete neurological and cranial nerve exam. Precontrast MRI; TSE/T2Wsequence in axial/coronal planes; 3D - HI-resolution T1W sagittal; FLAIR/T2W axial; FLAIR/T2W, Flash/T2W oblique coronal plane, GRE/T2W axial. Post-contrast TSE/T1W sequence in axial, coronal and sagittal planes. Diffusion weighted and ADC mapping, postcontrast: TSE/T1W sequence in axial, coronal and sagittal planes. Subsequent MRI of the brain revealed an oval and lobulated 47x34x30mm (TRxAPxCC) non-enhancing T1-hyperintense mass in right cavernous sinus, with compression of surrounding mesial temporal lobe and right anterolateral aspect of mesencephalon. Findings are consistent with ruptured dermoid cyst, given the evacuated sebum content at its lower half. Sebum particles in millimetric sizes are seen within right Sylvian fissure, anterior horns of lateral ventricles and to a lesser extent within left Sylvian fissure, right parietal sulci, cerebral aqueduct, and basal cisterns. No restricted diffusion is seen, eliminating the possibility of epidermoid. A shunt catheter is evident traversing between right lateral ventricle and right parietal bone; besides, slit-like right lateral ventricle is noted (likely secondary to over-draining shunt catheter). Intracranial dermoid cysts are benign rare slow-growing tumors that upon rupture, however, widespread presence of T1 hyperintense droplets and leptomeningeal enhancement can be noted-making MRI the best imaging modality for diagnosis of this rare entity.
Thermoregulation and habitat selection in wood turtles Glyptemys insculpta: chasing the sun slowly.
Dubois, Y; Blouin-Demers, G; Shipley, B; Thomas, D
2009-09-01
1. It is widely accepted that reptiles are able to regulate behaviourally their body temperature (T(b)), but this generalization is primarily based on studies of lizards and snakes in the temperate zone. Because the precision of T(b) regulation may vary considerably between taxa and over geographical ranges, studies of semi-terrestrial turtles in climatic extremes are relevant to the understanding of reptilian thermoregulation. 2. We studied thermoregulation in 21 free-ranging wood turtles (Glyptemys insculpta) at the northern limit of their range in Québec, using miniature data loggers to measure their internal T(b) and external temperature (T(ext)) continuously. We simultaneously recorded the available operative environmental temperature (T(e)) using 23 physical models randomly moved within each habitat type, and we located turtles using radiotelemetry. 3. The habitat used by wood turtles was thermally constraining and the target temperature (T(set)) was only achievable by basking during a short 5-h time window on sunny days. Wood turtles did show thermoregulatory abilities, as determined by the difference between turtle T(b) distribution and the null distribution of T(e) that resulted in T(b) closer to T(set). Although most individuals regulated their T(b) between 09.00 h and 16.00 h on sunny days, regulation was imprecise, as indicated by an index of thermoregulation precision (| T(b) - T(set) |). 4. The comparison of habitat use to availability indicated selection of open habitats. The hourly mean shuttling index (| T(ext) - T(b) |) suggested that turtles used sun/shade shuttling from 09.00 to 16.00 h to elevate their T(b) above mean T(e). 5. Based on laboratory respirometry data, turtles increased their metabolic rate by 20-26% over thermoconformity, and thus likely increased their energy gain which is assumed to be constrained by processing rate at climatic extremes.
TSETs Magnet Systems Cherrill Spencer Notes J C Vacuum Carl Rago Notes J C Supports & Movers Nancy Yu * Notes J C Installation Notes J C Manufacturing Morry Munro Notes J C Collimators & Dumps Eric Doyle Notes J C RF Distribution Engineering Notes M N Theory Perry Wilson - - Wednesday 10:30 A
ERIC Educational Resources Information Center
Hoyer, Grace
2013-01-01
The purpose of this study was to explore transcultural self-efficacy in nursing education administrators/faculty and to gain understanding of confidence related to lesbian, gay, bisexual, transgender (LGBT) issues. The 83-item Transcultural Self-Efficacy Tool (TSET) with an additional 11 LGBT questions was administered to 535 nursing education…
Cho, Hyun-Soo; Kang, Jeong Gu; Lee, Jae-Hye; Lee, Jeong-Ju; Jeon, Seong Kook; Ko, Jeong-Heon; Kim, Dae-Soo; Park, Kun-Hyang; Kim, Yong-Sam; Kim, Nam-Soon
2015-09-15
TALE-nuclease chimeras (TALENs) can bind to and cleave specific genomic loci and, are used to engineer gene knockouts and additions. Recently, instead of using the FokI domain, epigenetically active domains, such as TET1 and LSD1, have been combined with TAL effector domains to regulate targeted gene expression via DNA and histone demethylation. However, studies of histone methylation in the TALE system have not been performed. Therefore, in this study, we established a novel targeted regulation system with a TAL effector domain and a histone methylation domain. To construct a TALE-methylation fusion protein, we combined a TAL effector domain containing an E-Box region to act as a Snail binding site and the SET domain of EHMT 2 to allow for histone methylation. The constructed TALE-SET module (TSET) repressed the expression of E-cadherin via by increasing H3K9 dimethylation. Moreover, the cells that overexpressed TSET showed increased cell migration and invasion. This is the first phenotype-based study of targeted histone methylation by the TALE module, and this new system can be applied in new cancer therapies to reduce side effects.
Lourdais, Olivier; Guillon, Michaël; Denardo, Dale; Blouin-Demers, Gabriel
2013-07-02
We compared thermoregulatory strategies during pregnancy in two congeneric viperid snakes (Vipera berus and Vipera aspis) with parapatric geographic ranges. V. berus is a boreal specialist with the largest known distribution among terrestrial snakes while V. aspis is a south-European species. Despite contrasted climatic affinities, the two species displayed identical thermal preferences (Tset) in a laboratory thermal gradient. Under identical natural conditions, however, V. berus was capable of maintaining Tset for longer periods, especially when the weather was constraining. Consistent with the metabolic cold adaptation hypothesis, V. berus displayed higher standard metabolic rate at all temperatures considered. We used the thermal dependence of metabolic rate to calculate daily metabolic profiles from body temperature under natural conditions. The boreal specialist experienced higher daily metabolic rate and minimized gestation duration chiefly because of differences in the metabolic reaction norms, but also superior thermoregulatory efficiency. Under cold climates, thermal constraints should make precise thermoregulation costly. However, a shift in the metabolic reaction norm may compensate for thermal constraints and modify the cost-benefit balance of thermoregulation. Covariation between metabolic rate and thermoregulation efficiency is likely an important adaptation to cold climates. Copyright © 2013 Elsevier Inc. All rights reserved.
Row, Jeffrey R; Blouin-Demers, Gabriel
2006-05-01
We investigated the link between thermal quality and the effectiveness of thermoregulation in milk snakes in a thermally challenging environment. We defined thermoregulatory effectiveness as the extent to which an individual maintains its body temperature (Tb) closer to the preferred range (Tset) than allowed by the thermal quality of its environment. We defined thermal quality as the magnitude of the difference between operative environmental temperatures (Te) and Tset. Because ectotherms regulate body temperatures through choice of habitat and behavioural adjustments, we also examined the link between thermoregulation, habitat use and behaviour. During 2003-2004, we located 25 individuals 890 times, and recorded their Tb. Thermal quality was lower in the spring and fall than in the summer, and was lower in forests than in open habitats. Milk snakes thermoregulated more effectively in the spring than in the summer and fall, and more effectively in the forest than in open habitats. Milk snakes had a strong preference for open habitats in all seasons, which was likely to facilitate behavioural thermoregulation. The preference for open habitats was equally strong in all seasons and, therefore, the higher effectiveness of thermoregulation was not a result of altered habitat use. Instead, milk snakes modified their behaviour and were seen basking more and moved less in the spring than in the summer.
Abbreviated Combined MR Protocol: A New Faster Strategy for Characterizing Breast Lesions.
Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe
2016-06-01
The use of an abbreviated magnetic resonance (MR) protocol has been recently proposed for cancer screening. The aim of our study is to evaluate the diagnostic accuracy of an abbreviated MR protocol combining short TI inversion recovery (STIR), turbo-spin-echo (TSE)-T2 sequences, a pre-contrast T1, and a single intermediate (3 minutes after contrast injection) post-contrast T1 sequence for characterizing breast lesions. A total of 470 patients underwent breast MR examination for screening, problem solving, or preoperative staging. Two experienced radiologists evaluated both standard and abbreviated protocols in consensus. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy for both protocols were calculated (with the histological findings and 6-month ultrasound follow-up as the reference standard) and compared with the McNemar test. The post-processing and interpretation times for the MR images were compared with the paired t test. In 177 of 470 (38%) patients, the MR sequences detected 185 breast lesions. Standard and abbreviated protocols obtained sensitivity, specificity, diagnostic accuracy, PPV, and NPV values respectively of 92%, 92%, 92%, 68%, and 98% and of 89%, 91%, 91%, 64%, and 98% with no statistically significant difference (P < .0001). The mean post-processing and interpretation time were, respectively, 7 ± 1 minutes and 6 ± 3.2 minutes for the standard protocol and 1 ± 1.2 minutes and 2 ± 1.2 minutes for the abbreviated protocol, with a statistically significant difference (P < .01). An abbreviated combined MR protocol represents a time-saving tool for radiologists and patients with the same diagnostic potential as the standard protocol in patients undergoing breast MRI for screening, problem solving, or preoperative staging. Copyright © 2016 Elsevier Inc. All rights reserved.
Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Capolongo, Arcangela; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe
2014-07-01
Diffusion imaging represents a new imaging tool for the diagnosis of breast cancer. This study aims to investigate the role of diffusion-weighted MRI with background body signal suppression (DWIBS) for evaluating breast lesions. 90 patients were prospectively evaluated by MRI with STIR, TSE-T2, contrast enhanced THRIVE-T1 and DWIBS sequences. DWIBS were analyzed searching for the presence of breast lesions and calculating the ADC value. ADC values of ≤1.44×10(-3)mm(2)/s were considered suspicious for malignancy. This analysis was then compared with the histological findings. Sensitivity, specificity, diagnostic accuracy (DA), positive predictive value (PPV) and negative (NPV) were calculated. In 53/90 (59%) patients, DWIBS indicated the presence of breast lesions, 16 (30%) with ADC values of >1.44 and 37 (70%) with ADC≤1.44. The comparison with histology showed 25 malignant and 28 benign lesions. DWIBS sequences obtained sensitivity, specificity, DA, PPV and NPV values of 100, 82, 87, 68 and 100%, respectively. DWIBS can be proposed in the MRI breast protocol representing an accurate diagnostic complement. Copyright © 2014 Elsevier Inc. All rights reserved.
Moschetta, Marco; Telegrafo, Michele; Capuano, Giulia; Rella, Leonarda; Scardapane, Arnaldo; Angelelli, Giuseppe; Stabile Ianora, Amato Antonio
2013-10-01
To assess the contribute of intra-prosthetic MRI virtual navigation for evaluating breast implants and detecting implant ruptures. Forty-five breast implants were evaluated by MR examination. Only patients with a clinical indication were assessed. A 1.5-T device equipped with a 4-channel breast coil was used by performing axial TSE-T2, axial silicone-only, axial silicone suppression and sagittal STIR images. The obtained dicom files were also analyzed by using virtual navigation software. Two blinded radiologists evaluated all MR and virtual images. Eight patients for a total of 13 implants underwent surgical replacement. Sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) were calculated for both imaging strategies. Intra-capsular rupture was diagnosed in 13 out of 45 (29%) implants by using MRI. Basing on virtual navigation, 9 (20%) cases of intra-capsular rupture were diagnosed. Sensitivity, specificity, accuracy, PPV and NPV values of 100%, 86%, 89%, 62% and 100%, respectively, were found for MRI. Virtual navigation increased the previous values up to 100%, 97%, 98%, 89% and 100%. Intra-prosthetic breast MR virtual navigation can represent an additional promising tool for the evaluation of breast implants being able to reduce false positives and to provide a more accurate detection of intra-capsular implant rupture signs. Copyright © 2013 Elsevier Inc. All rights reserved.
Magnetic Resonance Imaging of a Case of Central Neurocytoma.
Dedushi, Kreshnike; Kabashi, Serbeze; Ugurel, Mehmet Sahin; Ramadani, Naser; Mucaj, Sefedin; Zeqiraj, Kamber
2016-12-01
The purpose of this study is to investigate the MRI features of central neurocytoma. A 45 year old man with 3 months of worsening daily headaches. These headaches were diffuse, lasted for several hours, and mostly occurred in the morning. She was initially diagnosed and treated for migraines but later he had epileptic attack and diplopia and neurolog recomaded MRI. precontrast MRI; TSE/T2Wsequence in axial/coronal planes; 3D-Hi-resolution T1W sagittal; FLAIR/T2W axial; FLAIR/T2W and Flash/T2W oblique coronal plane (perpendicular to temporal lobes) GRE/T2W axial plane for detection of heme products. Post-contrast TSE/T1W sequence in axial, coronal and sagittal planes. Diffusion weighted and ADC mapping MRI images for EPI sequence in axial plane. A 23x12mm heterogeneous mass within aqueductus cerebri, with calcified and hemorrhagic foci and extending downwards till fourth ventricle. It's originating from the right paramedian posterior aqueductal wall (tectum), and also extending to and involving the tegmentum of mesencephalon at its right paramedian aspect. CSF flow obstruction secondary to described aqueductal mass, with resultant triventricular hydrocephalus). Marked transependymal CSF leak can be noted at periventricular white matter, secondary to severe hydrocephalus. After IV injection of contrast media, this mass shows mild-to-moderate heterogenous speckled enhancement. MRI is helpful in defining tumor extension, which is important in preoperative planning. Although IN is a relatively rare lesion, it should be considered in the differential diagnosis of intraventricular lesions in the presence of such typical MR findings. However, a definitive diagnosis requires immunochemical study and electron microscopy.
Magnetic Resonance Imaging of a Case of Central Neurocytoma
Dedushi, Kreshnike; Kabashi, Serbeze; Ugurel, Mehmet Sahin; Ramadani, Naser; Mucaj, Sefedin; Zeqiraj, Kamber
2016-01-01
Background: The purpose of this study is to investigate the MRI features of central neurocytoma. Case report: A 45 year old man with 3 months of worsening daily headaches. These headaches were diffuse, lasted for several hours, and mostly occurred in the morning. She was initially diagnosed and treated for migraines but later he had epileptic attack and diplopia and neurolog recomaded MRI. Methods: precontrast MRI; TSE/T2Wsequence in axial/coronal planes; 3D–Hi-resolution T1W sagittal; FLAIR/T2W axial; FLAIR/T2W and Flash/T2W oblique coronal plane (perpendicular to temporal lobes) GRE/T2W axial plane for detection of heme products. Post-contrast TSE/T1W sequence in axial, coronal and sagittal planes. Diffusion weighted and ADC mapping MRI images for EPI sequence in axial plane. Results: A 23x12mm heterogeneous mass within aqueductus cerebri, with calcified and hemorrhagic foci and extending downwards till fourth ventricle. It’s originating from the right paramedian posterior aqueductal wall (tectum), and also extending to and involving the tegmentum of mesencephalon at its right paramedian aspect. CSF flow obstruction secondary to described aqueductal mass, with resultant triventricular hydrocephalus). Marked transependymal CSF leak can be noted at periventricular white matter, secondary to severe hydrocephalus. After IV injection of contrast media, this mass shows mild-to-moderate heterogenous speckled enhancement. Conclusion: MRI is helpful in defining tumor extension, which is important in preoperative planning. Although IN is a relatively rare lesion, it should be considered in the differential diagnosis of intraventricular lesions in the presence of such typical MR findings. However, a definitive diagnosis requires immunochemical study and electron microscopy. PMID:28077908
A Software Package for Neural Network Applications Development
NASA Technical Reports Server (NTRS)
Baran, Robert H.
1993-01-01
Original Backprop (Version 1.2) is an MS-DOS package of four stand-alone C-language programs that enable users to develop neural network solutions to a variety of practical problems. Original Backprop generates three-layer, feed-forward (series-coupled) networks which map fixed-length input vectors into fixed length output vectors through an intermediate (hidden) layer of binary threshold units. Version 1.2 can handle up to 200 input vectors at a time, each having up to 128 real-valued components. The first subprogram, TSET, appends a number (up to 16) of classification bits to each input, thus creating a training set of input output pairs. The second subprogram, BACKPROP, creates a trilayer network to do the prescribed mapping and modifies the weights of its connections incrementally until the training set is leaned. The learning algorithm is the 'back-propagating error correction procedures first described by F. Rosenblatt in 1961. The third subprogram, VIEWNET, lets the trained network be examined, tested, and 'pruned' (by the deletion of unnecessary hidden units). The fourth subprogram, DONET, makes a TSR routine by which the finished product of the neural net design-and-training exercise can be consulted under other MS-DOS applications.
Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe
2014-12-01
Diffusion-weighted imaging with background body signal suppression (DWIBS) provides both qualitative and quantitative imaging of breast lesions and are usually performed before contrast material injection (CMI). This study aims to assess whether the administration of gadolinium significantly affects DWIBS imaging. 200 patients were prospectively evaluated by MRI with STIR, TSE-T2, pre-CMI DWIBS, contrast enhanced THRIVE-T1 and post-CMI DWIBS sequences. Pre and post-CMI DWIBS were analyzed searching for the presence of breast lesions and calculating the ADC value. ADC values of ≤1.44×10(-3) mm(2)/s were considered suspicious for malignancy. This analysis was then compared with the histological findings. Sensitivity, specificity, diagnostic accuracy (DA), positive predictive value (PPV) and negative (NPV) were calculated for both sequences and represented by ROC analysis. Pre and post-CMI ADC values were compared by using the paired t test. In 150/200 (59%) patients, pre and post-CMI DWIBS indicated the presence of breast lesions, 53 (35%) with ADC values of >1.44×10(-3) mm(2)/s and 97 (65%) with ADC≤1.44×10(-3) mm(2)/s. Pre-CMI and post-DWIBS sequences obtained the same sensitivity, specificity, DA, PPV and NPV values of 97%, 83%, 89%, 79% and 98%. The mean ADC value of benign lesions was 1.831±0.18×10(-3) mm(2)/s before and 1.828±0.18×10(-3) mm(2)/s after CMI. The mean ADC value of the malignant lesions was 1.146±0.16×10(-3) mm(2)/s before and 1.144±0.16×10(-3) mm(2)/s after CMI. No significant difference was found between pre and post CMI ADC values (p>0.05). DWIBS imaging is not influenced by CMI. Breast MR protocol could be modified by placing DWIBS after dynamic contrast enhanced sequences in order to maximize patient cooperation. Copyright © 2014 Elsevier Inc. All rights reserved.
Losses, Expansions, and Novel Subunit Discovery of Adaptor Protein Complexes in Haptophyte Algae.
Lee, Laura J Y; Klute, Mary J; Herman, Emily K; Read, Betsy; Dacks, Joel B
2015-11-01
The phylum Haptophyta (Diaphoratickes) contains marine algae that perform biomineralization, extruding large, distinctive calcium carbonate scales (coccoliths) that completely cover the cell. Coccolith production is an important part of global carbon cycling; however, the membrane trafficking pathway by which they are secreted has not yet been elucidated. In most eukaryotes, post-Golgi membrane trafficking involves five heterotetrameric adaptor protein (AP) complexes, which impart cargo selection specificity. To better understand coccolith secretion, we performed comparative genomic, phylogenetic, and transcriptomic analyses of the AP complexes in Emiliania huxleyi strains 92A, Van556, EH2, and CCMP1516, and related haptophytes Gephyrocapsa oceanica and Isochrysis galbana; the latter has lost the ability to biomineralize. We show that haptophytes have a modified membrane trafficking system (MTS), as we found both AP subunit losses and duplications. Additionally, we identified a single conserved subunit of the AP-related TSET complex, whose expression suggests a functional role in membrane trafficking. Finally, we detected novel alpha adaptin ear and gamma adaptin ear proteins, the first of their kind to be described outside of opisthokonts. These novel ear proteins and the sculpting of the MTS may support the capacity for biomineralization in haptophytes, enhancing their ability to perform this highly specialized form of secretion. Copyright © 2015 Elsevier GmbH. All rights reserved.
Fog Simulations Based on Multi-Model System: A Feasibility Study
NASA Astrophysics Data System (ADS)
Shi, Chune; Wang, Lei; Zhang, Hao; Zhang, Su; Deng, Xueliang; Li, Yaosun; Qiu, Mingyan
2012-05-01
Accurate forecasts of fog and visibility are very important to air and high way traffic, and are still a big challenge. A 1D fog model (PAFOG) is coupled to MM5 by obtaining the initial and boundary conditions (IC/BC) and some other necessary input parameters from MM5. Thus, PAFOG can be run for any area of interest. On the other hand, MM5 itself can be used to simulate fog events over a large domain. This paper presents evaluations of the fog predictability of these two systems for December of 2006 and December of 2007, with nine regional fog events observed in a field experiment, as well as over a large domain in eastern China. Among the simulations of the nine fog events by the two systems, two cases were investigated in detail. Daily results of ground level meteorology were validated against the routine observations at the CMA observational network. Daily fog occurrences for the two study periods was validated in Nanjing. General performance of the two models for the nine fog cases are presented by comparing with routine and field observational data. The results of MM5 and PAFOG for two typical fog cases are verified in detail against field observations. The verifications demonstrated that all methods tended to overestimate fog occurrence, especially for near-fog cases. In terms of TS/ETS, the LWC-only threshold with MM5 showed the best performance, while PAFOG showed the worst. MM5 performed better for advection-radiation fog than for radiation fog, and PAFOG could be an alternative tool for forecasting radiation fogs. PAFOG did show advantages over MM5 on the fog dissipation time. The performance of PAFOG highly depended on the quality of MM5 output. The sensitive runs of PAFOG with different IC/BC showed the capability of using MM5 output to run the 1D model and the high sensitivity of PAFOG on cloud cover. Future works should intensify the study of how to improve the quality of input data (e.g. cloud cover, advection, large scale subsidence) for the 1D model, particularly how to eliminate near-fog case in fog forecasting.
Lista, F; Castillo, E; Gimbernat, H; Rodríguez-Barbero, J M; Panizo, J; Angulo, J C
2015-03-01
To assess the ability of multiparametric prostate magnetic resonance imaging (mpMRI) to detect prostate cancer in patients with prior negative transrectal prostate biopsy (TPB). mpMRI (TSE-T2-w, DWI and DCE sequences) was performed on 1.5T (Magnetom Avanto; Siemens Healthcare Solutions) in 150 patients suspicious of prostate cancer and with negative TPB. European Society of Urogenital Radiology (ESUR) criteria were used (score 1: clinically significant disease is highly unlikely to be present; score 2: clinically significant cancer is unlikely to be present; score 3: clinically significant cancer is equivocal; score 4: clinically significant cancer is likely to be present; score 5: clinically significant cancer is highly likely to be present). PSA measurement (total and free), digital rectal examination (DRE), transrectal ultrasound (TRU) and a second TPB (at least 14 cylinders) were performed in all patients. Variables were submitted for independent blind analysis. The accuracy of each test was measured. Stepwise selection model for prediction of prostate cancer in second TPB was developed. Mean age was 66.2± 5 years (51-77), mean PSA 11.3± 9.6ng/mL (0.9-75) and mean prostatic volume 82.2±42 (20-250) cc. DRE was suspicious in 11 (7.3%) patients. The mean number of cylinders per patient sampled in second TRB was 17.6±2.7(14-22). Second TRB was positive in 28 patients (18.7%). mpMRI was positive (score 3-5) in 102 (68%), test sensibility was 92.9% and the NPV was 95.8%. The risk of prostate cancer diagnosis in second TPB is modified by: PSA velocity > 0.75 (OR 1.04 [0.99-1.08]; P=0.06), free/total ratio PSA <15% (OR 0.37 [0.13-1.05]; P=0.06), each cc. of prostate volume (OR 0.98 [0.97-1]; P=0.017) and mpMRI 3-5 (OR 7.87 [1.78-34.7]; P=0.006). Multivariate analysis reveals that mpMRI (OR 7.41 [1.65-33.28]; P=0.009) and prostatic volume (OR 0.31 [0.12-0.78]; P=0.01) are independent risk predictors of prostate cancer. According to ESUR guidelines and in patients with prior negative prostate biopsy, mpMRI is a valuable tool for the prediction of prostate cancer in second TPB. Lower prostate volume, the higher reliability. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.
SU-E-T-193: FMEA Severity Scores - Do We Really Know?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khan, A; Robertson, JD; Narra, V
2014-06-01
Purpose: Mycosis fungoides is a common form of cutaneous T-cell lymphoma which generally affects the skin. A typical course of treatment may include fractionated total skin electron beam therapy. Given the difficulties in uniformly irradiating some regions of the body and the need for frequent visits within the context of a fractionated protocol, this study investigated the feasibility of delivering the dose using form-fitting cloth which contained phosphorous-32 as a source for beta particle irradiation. Methods: A piece of fabric (0.97 g) consisting of a blend of spandex and flame retardant material impregnated with phosphorus-31 (2000 ppm) was bombarded withmore » neutrons to produce phosphorus-32. The cloth was then laid flat and a stack of radiochromic film placed on top. Sheets of film and tissue equivalent plastic were layered to form a stack measuring a total of 1 cm thickness and remained sandwiched for 77.3 hr. Results: The initial activity of the activated cloth was 44 μCi of P-32. The absorbed dose was uniform within planes parallel to the cloth and exponentially dependent on depth, delivering 560cGy at 0.3mm and falling to 20cGy at 3mm. Conclusion: The total dose prescribed for a typical course of TSET for mycosis fungoides is 36Gy delivered over 9 weeks and is expected to treat to at least 5mm depth. Therefore, the P-32 impregnated cloth may not be clinically indicated to treat this disease given the unfavorable depth-dose characteristics. However, a major advantage of using form-fitting cloth is the uniformity with which the dose could be delivered over the skin in areas which are not flat. Increasing the distance between cloth and skin could improve the depth-dose characteristics.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and design...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Performance Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Performance Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Performance Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and design...
NASA Astrophysics Data System (ADS)
Qiu, Feng; Dai, Guang; Zhang, Ying
According to the acoustic emission information and the appearance inspection information of tank bottom online testing, the external factors associated with tank bottom corrosion status are confirmed. Applying artificial neural network intelligent evaluation method, three tank bottom corrosion status evaluation models based on appearance inspection information, acoustic emission information, and online testing information are established. Comparing with the result of acoustic emission online testing through the evaluation of test sample, the accuracy of the evaluation model based on online testing information is 94 %. The evaluation model can evaluate tank bottom corrosion accurately and realize acoustic emission online testing intelligent evaluation of tank bottom.
Testing and Evaluation of Passive Radiation Detection Equipment for Homeland Security
West, David L.; Wood, Nathan L.; Forrester, Christina D.
2017-12-01
This article is concerned with test and evaluation methods for passive radiation detection equipment used in homeland security applications. The different types of equipment used in these applications are briefly reviewed and then test and evaluation methods discussed. The primary emphasis is on the test and evaluation standards developed by the American National Standards Institute’s N42 committees. Commonalities among the standards are then reviewed as well as examples of unique aspects for specific equipment types. Throughout, sample test configurations and results from testing and evaluation at Oak Ridge National Laboratory are given. The article concludes with a brief discussion ofmore » typical tests and evaluations not covered by the N42 standards and some examples of test and evaluation that involve the end users of the equipment.« less
Testing and Evaluation of Passive Radiation Detection Equipment for Homeland Security
DOE Office of Scientific and Technical Information (OSTI.GOV)
West, David L.; Wood, Nathan L.; Forrester, Christina D.
This article is concerned with test and evaluation methods for passive radiation detection equipment used in homeland security applications. The different types of equipment used in these applications are briefly reviewed and then test and evaluation methods discussed. The primary emphasis is on the test and evaluation standards developed by the American National Standards Institute’s N42 committees. Commonalities among the standards are then reviewed as well as examples of unique aspects for specific equipment types. Throughout, sample test configurations and results from testing and evaluation at Oak Ridge National Laboratory are given. The article concludes with a brief discussion ofmore » typical tests and evaluations not covered by the N42 standards and some examples of test and evaluation that involve the end users of the equipment.« less
40 CFR 230.61 - Chemical, biological, and physical evaluation and testing.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Chemical, biological, and physical... FILL MATERIAL Evaluation and Testing § 230.61 Chemical, biological, and physical evaluation and testing... appropriate physical and chemical environmental characteristics. (d) Physical tests and evaluation. The effect...
1988-09-01
Test and Evaluation Report Test and Evaluation of the Navy Technical Information Presentation System (NTIPS) F-14A Field Test Results by .0 Joseph J...PROGRAM PROJECT TASK WORK UNIT Washington, D.C. 20361 ELEMENT NO. NO. NO. ACCESSION NO. OMN 1820 11. TITLE (Include Security Classification) TEST AND...EVALUATION OF THE NAVY TECHNICAL INFORMATION PRESENTATION SYSTEM (NTIPS) F-14A FIELD TEST RESULTS 12. PERSONAL AUTHOR(S) Fuller, Joseph F. (DTRC) Post
Reducing measurement errors during functional capacity tests in elders.
da Silva, Mariane Eichendorf; Orssatto, Lucas Bet da Rosa; Bezerra, Ewertton de Souza; Silva, Diego Augusto Santos; Moura, Bruno Monteiro de; Diefenthaeler, Fernando; Freitas, Cíntia de la Rocha
2018-06-01
Accuracy is essential to the validity of functional capacity measurements. To evaluate the error of measurement of functional capacity tests for elders and suggest the use of the technical error of measurement and credibility coefficient. Twenty elders (65.8 ± 4.5 years) completed six functional capacity tests that were simultaneously filmed and timed by four evaluators by means of a chronometer. A fifth evaluator timed the tests by analyzing the videos (reference data). The means of most evaluators for most tests were different from the reference (p < 0.05), except for two evaluators for two different tests. There were different technical error of measurement between tests and evaluators. The Bland-Altman test showed difference in the concordance of the results between methods. Short duration tests showed higher technical error of measurement than longer tests. In summary, tests timed by a chronometer underestimate the real results of the functional capacity. Difference between evaluators' reaction time and perception to determine the start and the end of the tests would justify the errors of measurement. Calculation of the technical error of measurement or the use of the camera can increase data validity.
Achievement Testing of Disadvantaged and Minority Students for Educational Program Evaluation.
ERIC Educational Resources Information Center
Wargo, Michael J., Ed.; Green, Donald Ross, Ed.
The following papers were delivered: Introductory Remarks, John W. Evans; An Evaluator's Perspective, Michael J. Wargo; Problems of Achievement Tests in Program Evaluation, Donald Ross Green; Diverse Human Populations and Problems in Educational Program Evaluation via Achievement Testing, Edmund W. Gordon; Critical Issues in Achievement Testing of…
Surface evaluation of UV-degraded contamination
NASA Technical Reports Server (NTRS)
Connatser, Robert; Hadaway, James B.
1992-01-01
Three different areas of work were accomplished under this contract: (1) contamination testing and evaluation; (2) UV irradiation testing; and (3) surface evaluation testing. Contamination testing was generally performed in the In-Situ Contamination Effects Facility at Marshall Space Flight Center (MSFC). UV irradiation testing was also performed primarily at MSFC, utilizing facilities there. Finally, the surface evaluation was done at facilities at UAH Center for Applied Optics.
40 CFR 610.25 - Evaluation of test data.
Code of Federal Regulations, 2012 CFR
2012-07-01
... base; (d) Definition of claims which can be made based on the available data; and (e) Substantiation of... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Evaluation of test data. 610.25... Analysis § 610.25 Evaluation of test data. Valid manufacturer-furnished test data will be evaluated with...
40 CFR 610.25 - Evaluation of test data.
Code of Federal Regulations, 2010 CFR
2010-07-01
... base; (d) Definition of claims which can be made based on the available data; and (e) Substantiation of... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Evaluation of test data. 610.25... Analysis § 610.25 Evaluation of test data. Valid manufacturer-furnished test data will be evaluated with...
40 CFR 610.25 - Evaluation of test data.
Code of Federal Regulations, 2013 CFR
2013-07-01
... base; (d) Definition of claims which can be made based on the available data; and (e) Substantiation of... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Evaluation of test data. 610.25... Analysis § 610.25 Evaluation of test data. Valid manufacturer-furnished test data will be evaluated with...
40 CFR 610.25 - Evaluation of test data.
Code of Federal Regulations, 2014 CFR
2014-07-01
... base; (d) Definition of claims which can be made based on the available data; and (e) Substantiation of... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Evaluation of test data. 610.25... Analysis § 610.25 Evaluation of test data. Valid manufacturer-furnished test data will be evaluated with...
40 CFR 610.25 - Evaluation of test data.
Code of Federal Regulations, 2011 CFR
2011-07-01
... base; (d) Definition of claims which can be made based on the available data; and (e) Substantiation of... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Evaluation of test data. 610.25... Analysis § 610.25 Evaluation of test data. Valid manufacturer-furnished test data will be evaluated with...
Tests and Measurements for Vocational Evaluators. April 1973.
ERIC Educational Resources Information Center
Botterbusch, Karl F.
The purpose of the document is to help fill the gap between the use of psychological tests by evaluators and evaluators' feelings about their competence in using these devices. The first section contains descriptions of 33 tests and instruments presently used in evaluation facilities serving a wide variety of clients. These tests are divided…
2008-11-01
103 2.3.6 Use of Model 4 for MANPRINT Evaluation of the M1A2 in the IOTE ..........103 iv 3. Conclusions...System (ASAS) Block II Initial Operational Test and Evaluation ( IOTE ) 203 Appendix I. Noise and Temperature Measurements in and Around the HETS...Test and Evaluation (LUTE), Initial Operational Test and Evaluation ( IOTE ) or a Follow-on Test and Evaluation (FOTE)—was being planned, our Field
NASA Astrophysics Data System (ADS)
Hart, D. M.; Merchant, B. J.; Abbott, R. E.
2012-12-01
The Component Evaluation project at Sandia National Laboratories supports the Ground-based Nuclear Explosion Monitoring program by performing testing and evaluation of the components that are used in seismic and infrasound monitoring systems. In order to perform this work, Component Evaluation maintains a testing facility called the FACT (Facility for Acceptance, Calibration, and Testing) site, a variety of test bed equipment, and a suite of software tools for analyzing test data. Recently, Component Evaluation has successfully integrated several improvements to its software analysis tools and test bed equipment that have substantially improved our ability to test and evaluate components. The software tool that is used to analyze test data is called TALENT: Test and AnaLysis EvaluatioN Tool. TALENT is designed to be a single, standard interface to all test configuration, metadata, parameters, waveforms, and results that are generated in the course of testing monitoring systems. It provides traceability by capturing everything about a test in a relational database that is required to reproduce the results of that test. TALENT provides a simple, yet powerful, user interface to quickly acquire, process, and analyze waveform test data. The software tool has also been expanded recently to handle sensors whose output is proportional to rotation angle, or rotation rate. As an example of this new processing capability, we show results from testing the new ATA ARS-16 rotational seismometer. The test data was collected at the USGS ASL. Four datasets were processed: 1) 1 Hz with increasing amplitude, 2) 4 Hz with increasing amplitude, 3) 16 Hz with increasing amplitude and 4) twenty-six discrete frequencies between 0.353 Hz to 64 Hz. The results are compared to manufacture-supplied data sheets.
Module Measurements | Photovoltaic Research | NREL
prototype concentrator evaluation test bed, and the Daystar DS-10/125 portable I-V curve tracer. Standard Evaluation Test Bed. We developed this test bed to be able to evaluate I-V characteristics throughout the day a function of time, temperature, and light level. This test bed data set is also used to evaluate
1982-05-01
MONITORING AND MANAGEMENT , 34 7.0 NONDESTRUCTIVE EVALUATION ( NDE ) 37 8. 0 SURFACE NDE 44 9.0 PERFORMANCE AND PROOF TESTING 46 10.0 SUMMARY AND...Chemical Quality Assurance Testing 2. Processability Testing 3. Cure Monitoring and Management 4. Nondestructive Evaluation ( NDE ) 5. Performance and...the management concept for implementing the specific tests. Chemical analysis, nondestructive evaluation ( NDE ) and environmental fatigue testing of
UH1-Y - Benefits and Deficiencies
2009-02-20
Report, NA 01 HCG -1 (hereinafter Test and Evaluation Report). 2 author’s experience. 3 Test and Evaluation Report. 4 Test and Evaluation Report...Critical Intelligence. Aug 14, 24(33). - - - 2008. DOD Approves Full Production for UH-1Y Despite Major Deficiency. Oct 2, 24(40). NA 01-11- HCG -2-1...2008. Operational Test and Evaluation Report, NA 01 HCG -1. Parmalee, Patricia, ed. 2005. Test Time. Aviation Week & Space Technology. Jun 20, 162
Using Optimization to Improve Test Planning
2017-09-01
friendly and to display the output differently, the test and evaluation test schedule optimization model would be a good tool for the test and... evaluation schedulers. 14. SUBJECT TERMS schedule optimization, test planning 15. NUMBER OF PAGES 223 16. PRICE CODE 17. SECURITY CLASSIFICATION OF...make the input more user-friendly and to display the output differently, the test and evaluation test schedule optimization model would be a good tool
Shuttle orbiter Ku-band radar/communications system design evaluation
NASA Technical Reports Server (NTRS)
Dodds, J.; Holmes, J.; Huth, G. K.; Iwasaki, R.; Maronde, R.; Polydoros, A.; Weber, C.; Broad, P.
1980-01-01
Tasks performed in an examination and critique of a Ku-band radar communications system for the shuttle orbiter are reported. Topics cover: (1) Ku-band high gain antenna/widebeam horn design evaluation; (2) evaluation of the Ku-band SPA and EA-1 LRU software; (3) system test evaluation; (4) critical design review and development test evaluation; (5) Ku-band bent pipe channel performance evaluation; (6) Ku-band LRU interchangeability analysis; and (7) deliverable test equipment evaluation. Where discrepancies were found, modifications and improvements to the Ku-band system and the associated test procedures are suggested.
Sharma, Vishal; Sundar, Sudha S; Breheny, Katie; Monahan, Mark; Sutton, Andrew John
2016-06-01
There are multiple tests available that can help diagnose ovarian cancer, and the cost-effective analysis of these diagnostic interventions is essential for making well-informed decisions regarding resource allocation. There are multiple factors that can impact on the conclusions drawn from economic evaluations including test accuracy, the impact of the testing pathway on patient costs and outcomes, and delays along the ovarian cancer test-treat pathway. The objective of this study was to evaluate how test accuracy, the choice of perspective, and delays along the testing and diagnostic pathway have been incorporated in economic evaluations of testing for ovarian cancer. A systematic review of published literature was undertaken to identify economic evaluations (eg, cost-effectiveness, cost-utility analysis) focused on testing and diagnosis for ovarian cancer. Seven studies met the inclusion criteria. Six studies incorporated test accuracy and its impact on patients to some extent. Four studies adopted a societal perspective, but only one considered the costs incurred by patients on the testing and diagnosis pathway. Where delays on the testing pathway were incorporated into the analysis, these were frequently due to false-negative test results leading to delays in patients accessing treatment. Any anxiety that patients might experience as a result of a positive test was not considered in these studies. The impact on patients of receiving a positive test in terms of anxiety and the costs incurred by patients having to attend for testing and diagnosis are rarely considered. Delays along the testing and diagnosis pathway can have a major effect on patient outcomes, and it is important that these are acknowledged in economic evaluations focused on testing. Future economic analysis should incorporate these key determinants in order that diagnostic tests for ovarian cancer can be robustly evaluated.
Joint High Speed Vessel (JHSV) Follow on Operational Test and Evaluation (FOT and E) Report
2015-09-21
Speed Vessel (JHSV) ship class. The events covered in this testing were not performed during the Initial Operational Test and Evaluation ( IOT &E...support boats since launch of these type boats was completed in IOT &E. 1 “Initial Operational Test...and Evaluation ( IOT &E) with Live Fire Test and Evaluation (LFT&E) on Joint High Speed Vessel (JHSV),” DOT&E, July 17, 2014. 2 MLP (CCS) is a heavy
Evaluating Diagnostic Point-of-Care Tests in Resource-Limited Settings
Drain, Paul K; Hyle, Emily P; Noubary, Farzad; Freedberg, Kenneth A; Wilson, Douglas; Bishai, William; Rodriguez, William; Bassett, Ingrid V
2014-01-01
Diagnostic point-of-care (POC) testing is intended to minimize the time to obtain a test result, thereby allowing clinicians and patients to make an expeditious clinical decision. As POC tests expand into resource-limited settings (RLS), the benefits must outweigh the costs. To optimize POC testing in RLS, diagnostic POC tests need rigorous evaluations focused on relevant clinical outcomes and operational costs, which differ from evaluations of conventional diagnostic tests. Here, we reviewed published studies on POC testing in RLS, and found no clearly defined metric for the clinical utility of POC testing. Therefore, we propose a framework for evaluating POC tests, and suggest and define the term “test efficacy” to describe a diagnostic test’s capacity to support a clinical decision within its operational context. We also proposed revised criteria for an ideal diagnostic POC test in resource-limited settings. Through systematic evaluations, comparisons between centralized diagnostic testing and novel POC technologies can be more formalized, and health officials can better determine which POC technologies represent valuable additions to their clinical programs. PMID:24332389
Uncertainty Evaluation of Residential Central Air-conditioning Test System
NASA Astrophysics Data System (ADS)
Li, Haoxue
2018-04-01
According to national standards, property tests of air-conditioning are required. However, test results could be influenced by the precision of apparatus or measure errors. Therefore, uncertainty evaluation of property tests should be conducted. In this paper, the uncertainties are calculated on the property tests of Xinfei13.6 kW residential central air-conditioning. The evaluation result shows that the property tests are credible.
2012-11-01
Research , Development, Test , and Evaluation (RDT&E) Appropriations The RDT&E appropriation consists of the mission program budgets for all... research , development, test and evaluation work performed by contractors and government installations and includes an installations and activities budget...than $4,000,000. 9 f. Research , Development, Test , and Evaluation Appropriations The Research , Development, Test , and Evaluation (RDT&E
Tegbaru, Belete; Messele, Tsehaynesh; Wolday, Dawit; Meles, PhD Hailu; Tesema, Desalegn; Birhanu, Hiwot; Tesfaye, Girma; Bond, Kyle B; Martin, Robert; Rayfield, Mark A; Wuhib, Tadesse; Fekadu, Makonnen
2004-10-01
Five simple and rapid HIV antibody detection assays viz. Determine, Capillus, Oraquick, Unigold and Hemastrip were evaluated to examine their performance and to develop an alternative rapid test based testing algorithm for voluntary counseling and testing (VCT) in Ethiopia. All the kits were tested on whole blood, plasma and serum. The evaluation had three phases: Primary lab review, piloting at point of service and implementation. This report includes the results of the first two phases. A total of 2,693 specimens (both whole blood and plasma) were included in the evaluation. Results were compared to double Enzyme Linked Immuno-Sorbent Assay (ELISA) system. Discordant EIA results were resolved using Western Blot. The assays had very good sensitivities and specificities, 99-100%, at the two different phases of the evaluation. A 98-100% result agreement was obtained from those tested at VCT centers and National Referral Laboratory for AIDS (NRLA), in the quality control phase of the evaluation. A testing strategy yielding 100% [95% CI; 98.9-100.0] sensitivity was achieved by the sequential use of the three rapid test kits. Direct cost comparison showed serial testing algorithm reduces the cost of testing by over 30% compared to parallel testing in the current situation. Determine, Capillus/Oraquick (presence/absence of frefrigeration) and Unigold were recommended as screening, confirmation and tiebreaker tests, respectively.
Evaluation of the concept of pressure proof testing fuselage structures
NASA Technical Reports Server (NTRS)
Harris, Charles E.; Orringer, Oscar
1991-01-01
The FAA and NASA have recently completed independent technical evaluations of the concept of pressure proof testing the fuselage of commercial transport airplanes. The results of these evaluations are summarized. The objectives of the evaluations were to establish the potential benefit of the pressure proof test, to quantify the most desirable proof test pressure, and to quantify the required proof test interval. The focus of the evaluations was on multiple-site cracks extending from adjacent rivet holes of a typical fuselage longitudinal lap splice joint. The FAA and NASA do not support pressure proof testing the fuselage of aging commercial transport aircraft. The argument against proof testing is as follows: (1) a single proof test does not insure an indefinite life; therefore, the proof test must be repeated at regular intervals; (2) for a proof factor of 1.33, the required proof test interval must be below 300 flights to account for uncertainties in the evaluation; (3) conducting the proof test at a proof factor of 1.5 would considerably exceed the fuselage design limit load; therefore, it is not consistent with accepted safe practices; and (4) better safety can be assured by implementing enhanced nondestructive inspection requirements, and adequate reliability can be achieved by an inspection interval several times longer than the proof test interval.
Economic Evaluations of Pathology Tests, 2010-2015: A Scoping Review.
Watts, Rory D; Li, Ian W; Geelhoed, Elizabeth A; Sanfilippo, Frank M; St John, Andrew
2017-09-01
Concerns about pathology testing such as the value provided by new tests and the potential for inappropriate utilization have led to a greater need to assess costs and benefits. Economic evaluations are a formal method of analyzing costs and benefits, yet for pathology tests, questions remain about the scope and quality of the economic evidence. To describe the extent and quality of published evidence provided by economic evaluations of pathology tests from 2010 to 2015. Economic evaluations relating to pathology tests from 2010 to 2015 were reviewed. Eight databases were searched for published studies, and details recorded for the country, clinical focus, type of testing, and consideration of sensitivity, specificity, and false test results. The reporting quality of studies was assessed using the Consolidated Health Economic Evaluation Reporting Standards checklist and cost-effectiveness ratios were analyzed for publication bias. We found 356 economic evaluations of pathology tests, most of which regarded developed countries. The most common economic evaluations were cost-utility analyses and the most common clinical focus was infectious diseases. More than half of the studies considered sensitivity and specificity, but few studies considered the impact of false test results. The average Consolidated Health Economic Evaluation Reporting Standards checklist score was 17 out of 24. Cost-utility ratios were commonly less than $10,000/quality-adjusted life-year or more than $200,000/quality-adjusted life-year. The number of economic evaluations of pathology tests has increased in recent years, but the rate of increase has plateaued. Furthermore, the quality of studies in the past 5 years was highly variable, and there is some question of publication bias in reporting cost-effectiveness ratios. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
The Role of Evaluation and Plans for Evaluating the Current Testing Program.
ERIC Educational Resources Information Center
Winters, Lynn
The Palos Verdes Peninsula Unified School District Office of Program Evaluation and Research is responsible for providing information for program development and improvement; providing test information to special programs coordinators; and acting as a clearinghouse for all information concerning tests, evaluation methodology, and educational…
Management and Capability ot the Major Range and Test Facility Bases
1995-07-27
The audit objective was to evaluate management oversight provided to the test ranges and determine whether management oversight could be streamlined... The audit also evaluated whether program managers were procuring test resources that already existed at the test ranges. Management controls related to the objectives were also evaluated.
Comparison of Development Test and Evaluation and Overall Program Estimate at Completion
2011-03-01
of the overall model and parameter. In addition to 36 the Shapiro-Wilkes test , and Cook’s Distance overlay plot we used the Breusch - Pagan test to...Transformed Model Finally, we evaluated our log transformed model using the Breusch - Pagan test . The results return a value of .51, thus confirming our...COMPARISON OF DEVELOPMENT TEST AND EVALUATION AND OVERALL
Economic evaluations of point of care testing strategies for active tuberculosis.
Zwerling, Alice; Dowdy, David
2013-06-01
Point of care (POC) diagnostics are often hailed as having the potential to transform tuberculosis (TB) control efforts. However, POC testing is better conceptualized as a system of diagnosis and treatment, not simply a test that can provide rapid, deployable results. Economic evaluations may help decision makers allocate scarce resources for TB control, but evaluations of POC testing face unique challenges that include evaluating the full diagnostic system, incorporating implementation costs, translating diagnostic results into health and accounting for downstream treatment costs. For economic evaluations to reach their full potential as decision-making tools for POC testing in TB, these challenges must be understood and addressed.
Strom, Suzanne L; Anderson, Craig L; Yang, Luanna; Canales, Cecilia; Amin, Alpesh; Lotfipour, Shahram; McCoy, C Eric; Osborn, Megan Boysen; Langdorf, Mark I
2015-11-01
Traditional Advanced Cardiac Life Support (ACLS) courses are evaluated using written multiple-choice tests. High-fidelity simulation is a widely used adjunct to didactic content, and has been used in many specialties as a training resource as well as an evaluative tool. There are no data to our knowledge that compare simulation examination scores with written test scores for ACLS courses. To compare and correlate a novel high-fidelity simulation-based evaluation with traditional written testing for senior medical students in an ACLS course. We performed a prospective cohort study to determine the correlation between simulation-based evaluation and traditional written testing in a medical school simulation center. Students were tested on a standard acute coronary syndrome/ventricular fibrillation cardiac arrest scenario. Our primary outcome measure was correlation of exam results for 19 volunteer fourth-year medical students after a 32-hour ACLS-based Resuscitation Boot Camp course. Our secondary outcome was comparison of simulation-based vs. written outcome scores. The composite average score on the written evaluation was substantially higher (93.6%) than the simulation performance score (81.3%, absolute difference 12.3%, 95% CI [10.6-14.0%], p<0.00005). We found a statistically significant moderate correlation between simulation scenario test performance and traditional written testing (Pearson r=0.48, p=0.04), validating the new evaluation method. Simulation-based ACLS evaluation methods correlate with traditional written testing and demonstrate resuscitation knowledge and skills. Simulation may be a more discriminating and challenging testing method, as students scored higher on written evaluation methods compared to simulation.
Liew, Jeffrey; Lench, Heather C; Kao, Grace; Yeh, Yu-Chen; Kwok, Oi-man
2014-01-01
Standardized testing has become a common form of student evaluation with high stakes, and limited research exists on understanding the roles of students' personality traits and social-evaluative threat on their academic performance. This study examined the roles of avoidance temperament (i.e., fear and behavioral inhibition) and evaluative threat (i.e., fear of failure and being viewed as unintelligent) in standardized math test and course grades in college students. Undergraduate students (N=184) from a large public university were assessed on temperamental fear and behavioral inhibition. They were then given 15 minutes to complete a standardized math test. After the test, students provided data on evaluative threat and their math performance (scores on standardized college entrance exam and average grades in college math courses). Results indicate that avoidance temperament was linked to social-evaluative threat and low standardized math test scores. Furthermore, evaluative threat mediated the influence of avoidance temperament on both types of math performance. Results have educational and clinical implications, particularly for students at risk for test anxiety and underperformance. Interventions targeting emotion regulation and stress management skills may help individuals reduce their math and test anxieties.
Paratransit Vehicle Test and Evaluation : Volume 3. Handling Tests.
DOT National Transportation Integrated Search
1978-06-01
A series of tests and evaluations of two prototype vehicles for paratransit were conducted. This volume (Volume III) presents the test procedures and results of the handling test series. The test determined the steering and handling characteristics o...
Receipt and Inspection of Chemical - Biological (CB) Materiel
2017-08-31
Policy and Standardization Division (CSTE-TM) U.S. Army Test and Evaluation Command 2202 Aberdeen Boulevard Aberdeen Proving Ground, MD 21005-5001...in this TOP is intended for use in the receipt inspection of CB materiel and systems tested by the U.S. Army Test and Evaluation Command (ATEC). The...This page is intentionally blank.) U.S. ARMY TEST AND EVALUATION COMMAND TEST OPERATIONS PROCEDURE *Test Operations Procedure 08-2-500A 31
Test Operations Procedure (TOP) 08-2-188 Chemical Point Detector Vapor Testing
2018-04-27
Evaluation Command 6617 Aberdeen Boulevard Aberdeen Proving Ground, MD 21005-5001 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR/MONITOR’S REPORT NUMBER(S...AND EVALUATION COMMAND TEST OPERATIONS PROCEDURE *Test Operations Procedure 08-2-188 27 April 2018 DTIC AD No. CHEMICAL POINT DETECTOR VAPOR...188 27 April 2018 2 1. SCOPE. This Test Operations Procedure (TOP), which has been endorsed by the Test and Evaluation Capabilities and
Study of an instrument for sensing errors in a telescope wavefront
NASA Technical Reports Server (NTRS)
Golden, L. J.; Shack, R. V.; Slater, P. N.
1974-01-01
Focal plane sensors for determining the error in a telescope wavefront were investigated. The construction of three candidate test instruments and their evaluation in terms of small wavefront error aberration measurements are described. A laboratory wavefront simulator was designed and fabricated to evaluate the test instruments. The laboratory wavefront error simulator was used to evaluate three tests; a Hartmann test, a polarization shearing interferometer test, and an interferometric Zernike test.
NASA Technical Reports Server (NTRS)
Maronde, R. G.
1980-01-01
The Ku-band test equipment, known as the Deliverable System Test equipment (DSTE), is reviewed and evaluated. The DSTE is semiautomated and computer programs were generated for 14 communication mode tests and 17 radar mode tests. The 31 test modules provide a good cross section of tests with which to exercise the Ku-band system; however, it is very limited when being used to verify Ku-band system performance. More detailed test descriptions are needed, and a major area of concern is the DSTE sell-off procedure which is inadequate.
Fidelity and Validity in Distributed Interactive Simulation: Questions and Answers
1992-11-01
future work in (a) collective training (b) the development and evaluation of tactical concepts and doctrine, (c) system test and evaluation, and (d...exercises. 14. SUBJECT TERMS 15. NUMBER OF PAGES distributed interactive simulation, simulation, training, test and evaluation, 37 simulator fidelity...revolutionizing future work in (a) collective training, (b) the development and evaluation of tactical concepts and doctrine, (c) system test and evaluation
Paratransit Vehicle Test and Evaluation : Volume 2. Acceleration and Interior Measurement Tests.
DOT National Transportation Integrated Search
1978-06-01
A series of tests and evaluations of two prototype vehicles for paratransit were conducted. This volume (Volume II) presents the test procedure and results of the acceleration and interior measurement test series. The tests determined the acceleratio...
Paratransit Vehicle Test and Evaluation : Volume 5. Noise Tests.
DOT National Transportation Integrated Search
1978-06-01
A series of tests and evaluations of two prototype paratransit vehicles were conducted. This volume (Volume V) presents the test procedures and results of the noise tests conducted on the two paratransit vehicles and the baseline test vehicle. The te...
2016-09-01
Standardization (ISO). 2015. Water quality - calanoid copepod early- life stage test with Acartia tonsa. ISO 16778:2015. International Organization for...Toxicity Test Methods for Marine Water Quality Evaluations by Alan J Kennedy, Guilherme Lotufo, Jennifer G. Laird, and J. Daniel Farrar PURPOSE: The...MPRSA evaluations in some regions. The organisms used in these test methods are not planktonic for most of their life cycles (juveniles and adults
ERIC Educational Resources Information Center
Spielberg, Freya; Kurth, Ann; Reidy, William; McKnight, Teka; Dikobe, Wame; Wilson, Charles
2011-01-01
This article highlights findings from an evaluation that explored the impact of mobile versus clinic-based testing, rapid versus central-lab based testing, incentives for testing, and the use of a computer counseling program to guide counseling and automate evaluation in a mobile program reaching people of color at risk for HIV. The program's…
Responding to the UNDP Evaluations Unit
ERIC Educational Resources Information Center
Lempert, David H.
2012-01-01
The author of an indicator that tests evaluation system compliance with good governance principles addresses the UNDP's response to his article by offering an empirical test of the UNDP's commitment to reform. While the UNDP Evaluations Office claims to be working on reforms, the test exposes the unwillingness of the UNDP Evaluations Office to…
Gera, G; Freeman, D L; Blackinton, M T; Horak, F B; King, L
2016-02-01
Balance deficits in people with Parkinson's disease can affect any of the multiple systems encompassing balance control. Thus, identification of the specific deficit is crucial in customizing balance rehabilitation. The sensory organization test, a test of sensory integration for balance control, is sometimes used in isolation to identify balance deficits in people with Parkinson's disease. More recently, the Mini-Balance Evaluations Systems Test, a clinical scale that tests multiple domains of balance control, has begun to be used to assess balance in patients with Parkinson's disease. The purpose of our study was to compare the use of Sensory Organization Test and Mini-Balance Evaluations Systems Test in identifying balance deficits in people with Parkinson's disease. 45 participants (27M, 18F; 65.2 ± 8.2 years) with idiopathic Parkinson's disease participated in the cross-sectional study. Balance assessment was performed using the Sensory Organization Test and the Mini-Balance Evaluations Systems Test. People were classified into normal and abnormal balance based on the established cutoff scores (normal balance: Sensory Organization Test >69; Mini-Balance Evaluations Systems Test >73). More subjects were classified as having abnormal balance with the Mini-Balance Evaluations Systems Test (71% abnormal) than with the Sensory Organization Test (24% abnormal) in our cohort of people with Parkinson's disease. There were no subjects with a normal Mini-Balance Evaluations Systems Test score but abnormal Sensory Organization Test score. In contrast, there were 21 subjects who had an abnormal Mini-Balance Evaluations Systems Test score but normal Sensory Organization Test scores. Findings from this study suggest that investigation of sensory integration deficits, alone, may not be able to identify all types of balance deficits found in patients with Parkinson's disease. Thus, a comprehensive approach should be used to test of multiple balance systems to provide customized rehabilitation.
Paratransit Vehicle Test and Evaluation : Volume 4. Fuel Economy Tests.
DOT National Transportation Integrated Search
1978-06-01
A series of tests and evaluations of two prototype vehicles for paratransit were conducted. This volume (Volume IV) presents the test procedures and results of the fuel economy tests. The test series determined the fuel economy of the vehicles as the...
NASA Technical Reports Server (NTRS)
Berg, Melanie D.; LaBel, Kenneth A.
2018-01-01
The following are updated or new subjects added to the FPGA SEE Test Guidelines manual: academic versus mission specific device evaluation, single event latch-up (SEL) test and analysis, SEE response visibility enhancement during radiation testing, mitigation evaluation (embedded and user-implemented), unreliable design and its affects to SEE Data, testing flushable architectures versus non-flushable architectures, intellectual property core (IP Core) test and evaluation (addresses embedded and user-inserted), heavy-ion energy and linear energy transfer (LET) selection, proton versus heavy-ion testing, fault injection, mean fluence to failure analysis, and mission specific system-level single event upset (SEU) response prediction. Most sections within the guidelines manual provide information regarding best practices for test structure and test system development. The scope of this manual addresses academic versus mission specific device evaluation and visibility enhancement in IP Core testing.
NASA Technical Reports Server (NTRS)
Berg, Melanie D.; LaBel, Kenneth A.
2018-01-01
The following are updated or new subjects added to the FPGA SEE Test Guidelines manual: academic versus mission specific device evaluation, single event latch-up (SEL) test and analysis, SEE response visibility enhancement during radiation testing, mitigation evaluation (embedded and user-implemented), unreliable design and its affects to SEE Data, testing flushable architectures versus non-flushable architectures, intellectual property core (IP Core) test and evaluation (addresses embedded and user-inserted), heavy-ion energy and linear energy transfer (LET) selection, proton versus heavy-ion testing, fault injection, mean fluence to failure analysis, and mission specific system-level single event upset (SEU) response prediction. Most sections within the guidelines manual provide information regarding best practices for test structure and test system development. The scope of this manual addresses academic versus mission specific device evaluation and visibility enhancement in IP Core testing.
DECIDE: a software for computer-assisted evaluation of diagnostic test performance.
Chiecchio, A; Bo, A; Manzone, P; Giglioli, F
1993-05-01
The evaluation of the performance of clinical tests is a complex problem involving different steps and many statistical tools, not always structured in an organic and rational system. This paper presents a software which provides an organic system of statistical tools helping evaluation of clinical test performance. The program allows (a) the building and the organization of a working database, (b) the selection of the minimal set of tests with the maximum information content, (c) the search of the model best fitting the distribution of the test values, (d) the selection of optimal diagnostic cut-off value of the test for every positive/negative situation, (e) the evaluation of performance of the combinations of correlated and uncorrelated tests. The uncertainty associated with all the variables involved is evaluated. The program works in a MS-DOS environment with EGA or higher performing graphic card.
Evaluation of Inter-Mountain Labs infrasound sensors : July 2007.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, Darren M.
2007-10-01
Sandia National Laboratories has tested and evaluated three Inter Mountain Labs infrasound sensors. The test results included in this report were in response to static and tonal-dynamic input signals. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters; others were designed by Sandia specifically for infrasound application evaluation and for supplementary criteria not addressed in the IEEE standards. The objective of this work was to evaluate the overall technical performance of the Inter Mountain Labs (IML) infrasound sensor model SS. The results of this evaluation were only comparedmore » to relevant noise models; due to a lack of manufactures documentation notes on the sensors under test prior to testing. The tests selected for this system were chosen to demonstrate different performance aspects of the components under test.« less
2017-09-01
NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS TEST AND EVALUATION OF AN IMAGE-MATCHING NAVIGATION SYSTEM FOR A UAS OPERATING IN A GPS-DENIED...INTENTIONALLY LEFT BLANK ii Approved for public release. Distribution is unlimited. TEST AND EVALUATION OF AN IMAGE-MATCHING NAVIGATION SYSTEM FOR A UAS... Evaluation Setup and Procedures 39 4.1 Test Equipment and Data Collection Procedures . . . . . . . . . . . . 39 4.2 Actual Flight Data Collection
Towards an evaluation framework for Laboratory Information Systems.
Yusof, Maryati M; Arifin, Azila
Laboratory testing and reporting are error-prone and redundant due to repeated, unnecessary requests and delayed or missed reactions to laboratory reports. Occurring errors may negatively affect the patient treatment process and clinical decision making. Evaluation on laboratory testing and Laboratory Information System (LIS) may explain the root cause to improve the testing process and enhance LIS in supporting the process. This paper discusses a new evaluation framework for LIS that encompasses the laboratory testing cycle and the socio-technical part of LIS. Literature review on discourses, dimensions and evaluation methods of laboratory testing and LIS. A critical appraisal of the Total Testing Process (TTP) and the human, organization, technology-fit factors (HOT-fit) evaluation frameworks was undertaken in order to identify error incident, its contributing factors and preventive action pertinent to laboratory testing process and LIS. A new evaluation framework for LIS using a comprehensive and socio-technical approach is outlined. Positive relationship between laboratory and clinical staff resulted in a smooth laboratory testing process, reduced errors and increased process efficiency whilst effective use of LIS streamlined the testing processes. The TTP-LIS framework could serve as an assessment as well as a problem-solving tool for the laboratory testing process and system. Copyright © 2016 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.
40 CFR 610.33 - Durability tests.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Durability tests. 610.33 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.33 Durability tests. The Administrator may determine that a device under evaluation will require durability testing in...
40 CFR 610.33 - Durability tests.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Durability tests. 610.33 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.33 Durability tests. The Administrator may determine that a device under evaluation will require durability testing in...
40 CFR 610.33 - Durability tests.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Durability tests. 610.33 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.33 Durability tests. The Administrator may determine that a device under evaluation will require durability testing in...
40 CFR 610.33 - Durability tests.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Durability tests. 610.33 Section 610... RETROFIT DEVICES Test Procedures and Evaluation Criteria Test Requirement Criteria § 610.33 Durability tests. The Administrator may determine that a device under evaluation will require durability testing in...
Construction and Evaluation of Reliability and Validity of Reasoning Ability Test
ERIC Educational Resources Information Center
Bhat, Mehraj A.
2014-01-01
This paper is based on the construction and evaluation of reliability and validity of reasoning ability test at secondary school students. In this paper an attempt was made to evaluate validity, reliability and to determine the appropriate standards to interpret the results of reasoning ability test. The test includes 45 items to measure six types…
Testing and evaluation of tactical electro-optical sensors
NASA Astrophysics Data System (ADS)
Middlebrook, Christopher T.; Smith, John G.
2002-07-01
As integrated electro-optical sensor payloads (multi- sensors) comprised of infrared imagers, visible imagers, and lasers advance in performance, the tests and testing methods must also advance in order to fully evaluate them. Future operational requirements will require integrated sensor payloads to perform missions at further ranges and with increased targeting accuracy. In order to meet these requirements sensors will require advanced imaging algorithms, advanced tracking capability, high-powered lasers, and high-resolution imagers. To meet the U.S. Navy's testing requirements of such multi-sensors, the test and evaluation group in the Night Vision and Chemical Biological Warfare Department at NAVSEA Crane is developing automated testing methods, and improved tests to evaluate imaging algorithms, and procuring advanced testing hardware to measure high resolution imagers and line of sight stabilization of targeting systems. This paper addresses: descriptions of the multi-sensor payloads tested, testing methods used and under development, and the different types of testing hardware and specific payload tests that are being developed and used at NAVSEA Crane.
Improving Beta Test Evaluation Response Rates: A Meta-Evaluation
ERIC Educational Resources Information Center
Russ-Eft, Darlene; Preskill, Hallie
2005-01-01
This study presents a meta-evaluation of a beta-test of a customer service training program. The initial evaluation showed a low response rate. Therefore, the meta-evaluation focused on issues related to the conduct of the initial evaluation and reasons for nonresponse. The meta-evaluation identified solutions to the nonresponse problem as related…
Koekkoek, P S; Janssen, J; Kooistra, M; Biesbroek, J M; Groeneveld, O; van den Berg, E; Kappelle, L J; Biessels, G J; Rutten, G E H M
2016-06-01
To evaluate two cognitive tests for case-finding for cognitive impairment in older patients with Type 2 diabetes. Of 1243 invited patients with Type 2 diabetes, aged ≥70 years, 228 participated in a prospective cohort study. Exclusion criteria were: diagnosis of dementia; previous investigation at a memory clinic; and inability to write or read. Patients first filled out two self-administered cognitive tests (Test Your Memory and Self-Administered Gerocognitive Examination). Secondly, a general practitioner, blinded to Test Your Memory and Self-Administered Gerocognitive Examination scores, performed a structured evaluation using the Mini-Mental State Examination. Subsequently, patients suspected of cognitive impairment (on either the cognitive tests or general practitioner evaluation) and a random sample of 30% of patients not suspected of cognitive impairment were evaluated at a memory clinic. Diagnostic accuracy and area under the curve were determined for the Test Your Memory, Self-Administered Gerocognitive Examination and general practitioner evaluation compared with a memory clinic evaluation to detect cognitive impairment (mild cognitive impairment or dementia). A total of 44 participants were diagnosed with cognitive impairment. The Test Your Memory and Self-Administered Gerocognitive Examination questionnaires had negative predictive values of 81 and 85%, respectively. Positive predictive values were 39 and 40%, respectively. The general practitioner evaluation had a negative predictive value of 83% and positive predictive value of 64%. The area under the curve was ~0.70 for all tests. Both the tests evaluated in the present study can easily be used in case-finding strategies for cognitive impairment in patients with Type 2 diabetes in primary care. The Self-Administered Gerocognitive Examination had the best diagnostic accuracy and therefore we would have a slight preference for this test. Applying the Self-Administered Gerocognitive Examination would considerably reduce the number of patients in whom the general practitioner needs to evaluate cognitive functioning to tailor diabetes treatment. © 2015 Diabetes UK.
2017-11-01
The Under-body Blast Methodology (UBM) for the Test and Evaluation (T&E) program was established to provide a capability for the US Army Test and... Evaluation Command to assess the vulnerability of vehicles to under-body blast. Finite element (FE) models are part of the current UBM for T&E methodology...Methodology (UBM) for the Test and Evaluation (T&E) program was established to provide a capability for the US Army Test and Evaluation Command
2015-08-01
Initial Operational Test and Evaluation ( IOT &E) and the system’s operational effectiveness, operational suitability, and cybersecurity. The Air Force...Operational Test and Evaluation Center (AFOTEC) conducted the IOT &E between October 1, 2014, and May 29, 2015, at seven bases that included three...at McConnell Air Force Base (AFB), Kansas. Adequacy of IOT &E The IOT &E was adequate and was executed in accordance with the Test and Evaluation
SOAR 89: Space Station. Space suit test program
NASA Technical Reports Server (NTRS)
Kosmo, Joseph J.; West, Philip; Rouen, Michael
1990-01-01
The elements of the test program for the space suit to be used on Space Station Freedom are noted in viewgraph form. Information is given on evaluation objectives, zero gravity evaluation, mobility evaluation, extravehicular activity task evaluation, and shoulder joint evaluation.
A Portable Environment Test System: A Field Assessment of Organotin Leachates--Test and Evaluation.
1987-11-01
Environmental Test System (PETS) was evaluated with tributyltin ( TBT ) anti oling leachates in Sin Diego Bay over a 7-month period. Overall mean test...EXECUTIVE SUMMARY A Portable Environmental Test System (PETS) was evaluated with tributyltin ( TBT ) antifouling leachates in San Diego Bay for 7...of organotin-based antifouling (AF) coatings, NOSC researchers used this facility to study the effects of tributyltin ( TBT ), the primary toxic
[Tests of hand functionality in upper limb amputation with prosthesis].
Bazzini, G; Orlandini, D; Moscato, T A; Nicita, D; Panigazzi, M
2007-01-01
The need for standardized instruments for clinical measurements has become pressing in the fields of occupational rehabilitation and ergonomics. This is particularly the case for instruments that allow a quantitative evaluation of upper limb function, and especially hand function in patients who have undergone an amputation and then application of an upper limb prosthesis. This study presents a review of the main tests used to evaluate hand function, with a critical analysis of their use in subjects with an upper limb prosthesis. The tests are divided into: tests to evaluate strength, tests to evaluate co-ordination and dexterity, tests of global or overall function, and tests proposed specifically for subjects with an upper limb prosthesis. Of the various tests presented, the authors give their preference to the Bimanual Functional Assessment, Abilhand and/or the ADL Questionnaire, because of the practical usefulness, clinimetric features, simplicity and ease of administration of these tests.
Kidney function tests are common lab tests used to evaluate how well the kidneys are working. Such tests include: ... Oh MS, Briefel G. Evaluation of renal function, water, electrolytes ... and Management by Laboratory Methods . 23rd ed. Philadelphia, ...
Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR)
2008-12-01
the standard SETCO tires. A blast test of the new SETCO tire is scheduled for the spring of...Washington, DC 20301-2500 Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR) December 2008 Prepared ...2008 to 00-00-2008 4. TITLE AND SUBTITLE Performance Evaluation Test of the Rapid Area Preparation Tool (RAPTOR) 5a. CONTRACT NUMBER 5b.
Small Scale Trace Contaminant Testing of SA9T at Ambient and Reduced Pressure Conditions
NASA Technical Reports Server (NTRS)
Broerman, Craig; Sweterlitsch, Jeffrey
2011-01-01
A principle concern for air revitalization technology in a closed loop system is the capability to control carbon dioxide (CO2) and humidity (H2O). An amine based sorbent technology, SA9T, has long been evaluated for use in this application and several programs are evaluating it for use in both a cabin as well as space suit applications. While the CO2 and H2O performance of the sorbent has been tested extensively, the question of how trace contaminants impact performance requires further evaluation. This paper presents experimental results of small scale SA9T testing that was performed over a variety of test conditions and with a variety of trace contaminants. Testing evaluated the ability of SA9T media to sufficiently remove CO2 and H2O after exposure to a fully saturated trace contaminant at ambient conditions. Testing also evaluated the impact of CO2 and H2O removal performance at suit loop pressures during cyclic operation with a constant inlet contaminant load. In addition, testing evaluated the performance of SA9T at ambient conditions in a continuous 30-day test with a mixed trace contaminant stream.
NASA Technical Reports Server (NTRS)
Wood, Charles C.
1991-01-01
The following topics are presented in tabular form: (1) simulation capability assessments (no propulsion system test); (2) advanced vehicle simulation capability assessment; (3) systems tests identified events; (4) main propulsion test article (MPTA) testing evaluation; (5) Saturn 5, 1B, and 1 testing evaluation. Special vehicle simulation issues that are propulsion related are briefly addressed.
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1979-01-01
All evaluation tests were performed at room ambient pressure and temperature, with discharges at a 2 hour rate. Tests consisted of phenolphthalein leak tests, three capacity tests, an auxiliary electrode test, a charge retention test, an internal short test, a charge efficiency test, overcharge tests, and a pressure versus capacity test. Results of the tests and recommendations for improvements in manufacturing are presented.
The use of one- versus two-tailed tests to evaluate prevention programs.
Ringwalt, Chris; Paschall, M J; Gorman, Dennis; Derzon, James; Kinlaw, Alan
2011-06-01
Investigators have used both one- and two-tailed tests to determine the significance of findings yielded by program evaluations. While the literature that addresses the appropriate use of each type of significance test should be used is historically inconsistent, almost all authorities now agree that one-tailed tests are rarely (if ever) appropriate. A review of 85 published evaluations of school-based drug prevention curricula specified on the National Registry of Effective Programs and Practices revealed that 20% employed one-tailed tests and, within this subgroup, an additional 4% also employed two-tailed tests. The majority of publications either did not specify the type of statistical test employed or used some other criterion such as effect sizes or confidence intervals. Evaluators reported that they used one-tailed tests either because they stipulated the direction of expected findings in advance, or because prior evaluations of similar programs had yielded no negative results. The authors conclude that one-tailed tests should never be used because they introduce greater potential for Type I errors and create an uneven playing field when outcomes are compared across programs. The authors also conclude that the traditional threshold of significance that places α at .05 is arbitrary and obsolete, and that evaluators should consistently report the exact p values they find.
Materials Compatibility Testing in Concentrated Hydrogen Peroxide
NASA Technical Reports Server (NTRS)
Boxwell, R.; Bromley, G.; Mason, D.; Crockett, D.; Martinez, L.; McNeal, C.; Lyles, G. (Technical Monitor)
2000-01-01
Materials test methods from the 1960's have been used as a starting point in evaluating materials for today's space launch vehicles. These established test methods have been modified to incorporate today's analytical laboratory equipment. The Orbital test objective was to test a wide range of materials to incorporate the revolution in polymer and composite materials that has occurred since the 1960's. Testing is accomplished in 3 stages from rough screening to detailed analytical tests. Several interesting test observations have been made during this testing and are included in the paper. A summary of the set-up, test and evaluation of long-term storage sub-scale tanks is also included. This sub-scale tank test lasted for a 7-month duration prior to being stopped due to a polar boss material breakdown. Chemical evaluations of the hydrogen peroxide and residue left on the polar boss surface identify the material breakdown quite clearly. The paper concludes with recommendations for future testing and a specific effort underway within the industry to standardize the test methods used in evaluating materials.
Knight, Jean; Rovida, Costanca
2014-01-01
The proposed Safe Cosmetics and Personal Care Products Act of 2013 calls for a new evaluation program for cosmetic ingredients in the US, with the new assessments initially dependent on expanded animal testing. This paper considers possible testing scenarios under the proposed Act and estimates the number of test animals and cost under each scenario. It focuses on the impact for the first 10 years of testing, the period of greatest impact on animals and costs. The analysis suggests the first 10 years of testing under the Act could evaluate, at most, about 50% of ingredients used in cosmetics. Testing during this period would cost about $ 1.7-$ 9 billion and 1-11.5 million animals. By test year 10, alternative, high-throughput test methods under development are expected to be available, replacing animal testing and allowing rapid evaluation of all ingredients. Given the high cost in dollars and animal lives of the first 10 years for only about half of ingredients, a better choice may be to accelerate development of high-throughput methods. This would allow evaluation of 100% of cosmetic ingredients before year 10 at lower cost and without animal testing.
NASA Technical Reports Server (NTRS)
Wilson, D. J.; Krause, M. C.; Craven, C. E.; Edwards, B. B.; Coffey, E. W.; Huang, C. C.; Jetton, J. L.; Morrison, L. K.
1974-01-01
A program plan for system evaluation of the two-dimensional Scanning Laser Doppler System (SLDS) is presented. In order to meet system evaluation and optimization objectives the following tests were conducted: (1) noise tests; (2) wind tests; (3) blower flowfield tests; (4) single unit (1-D) flyby tests; and (5) dual unit (2-D) flyby tests. Test results are reported. The final phase of the program included logistics preparation, equipment interface checkouts, and data processing. It is concluded that the SLDS is capable of accurately tracking aircraft wake vortices from small or large aircraft, and in any type of weather.
EVALUATION OF A FIELD TEST KIT FOR MONITORING LEAD IN DRINKING WATER.
This article describes a conceptual framework for designing evaluation studies of test kits for the analysis of significant drinking water constituents. A commercial test kit for the analysis of lead in tap waters was evaluated and compared with a standard graphite furnace atomic...
DOT National Transportation Integrated Search
1998-08-01
This report describes the DIRECT field test which was designed to evaluate the user benefits, institutional issues, and technical issues of en-route driver advisory and traveler information services. Focus was on testing and evaluating the voice-base...
Underground coal mine instrumentation and test
NASA Technical Reports Server (NTRS)
Burchill, R. F.; Waldron, W. D.
1976-01-01
The need to evaluate mechanical performance of mine tools and to obtain test performance data from candidate systems dictate that an engineering data recording system be built. Because of the wide range of test parameters which would be evaluated, a general purpose data gathering system was designed and assembled to permit maximum versatility. A primary objective of this program was to provide a specific operating evaluation of a longwall mining machine vibration response under normal operating conditions. A number of mines were visited and a candidate for test evaluation was selected, based upon management cooperation, machine suitability, and mine conditions. Actual mine testing took place in a West Virginia mine.
ERIC Educational Resources Information Center
Rodgers, Joseph Lee; Rodgers, Jacci L.
2011-01-01
We propose, develop, and evaluate the black ink-red ink (BIRI) method of testing. This approach uses two different methods within the same test administration setting, one that matches recognition learning and the other that matches recall learning. Students purposively define their own tradeoff between the two approaches. Evaluation of the method…
2015-05-01
Director, Operational Test and Evaluation Department of Defense (DOD) Automated Biometric Identification System (ABIS) Version 1.2 Initial...Operational Test and Evaluation Report May 2015 This report on the Department of Defense (DOD) Automated Biometric Identification System...COVERED - 4. TITLE AND SUBTITLE Department of Defense (DOD) Automated Biometric Identification System (ABIS) Version 1.2 Initial Operational Test
2017-01-01
procedures and Army doctrine. During pre -IOT&E training and developmental testing , the combat developer discovered that when projectiles were fired using...Director, Operational Test and Evaluation M109 Family of Vehicles, Paladin Integrated Management (PIM) Operational Assessment of the...Initial Operational Test and Evaluation October 2011 January 2017 J. Michael Gilmore Director
Spielberg, Freya; Kurth, Ann; Reidy, William; McKnight, Teka; Dikobe, Wame; Wilson, Charles
2011-06-01
This article highlights findings from an evaluation that explored the impact of mobile versus clinic-based testing, rapid versus central-lab based testing, incentives for testing, and the use of a computer counseling program to guide counseling and automate evaluation in a mobile program reaching people of color at risk for HIV. The program's results show that an increased focus on mobile outreach using rapid testing, incentives and health information technology tools may improve program acceptability, quality, productivity and timeliness of reports. This article describes program design decisions based on continuous quality assessment efforts. It also examines the impact of the Computer Assessment and Risk Reduction Education computer tool on HIV testing rates, staff perception of counseling quality, program productivity, and on the timeliness of evaluation reports. The article concludes with a discussion of implications for programmatic responses to the Centers for Disease Control and Prevention's HIV testing recommendations.
Spielberg, Freya; Kurth, Ann; Reidy, William; McKnight, Teka; Dikobe, Wame; Wilson, Charles
2016-01-01
This article highlights findings from an evaluation that explored the impact of mobile versus clinic-based testing, rapid versus central-lab based testing, incentives for testing, and the use of a computer counseling program to guide counseling and automate evaluation in a mobile program reaching people of color at risk for HIV. The program’s results show that an increased focus on mobile outreach using rapid testing, incentives and health information technology tools may improve program acceptability, quality, productivity and timeliness of reports. This article describes program design decisions based on continuous quality assessment efforts. It also examines the impact of the Computer Assessment and Risk Reduction Education computer tool on HIV testing rates, staff perception of counseling quality, program productivity, and on the timeliness of evaluation reports. The article concludes with a discussion of implications for programmatic responses to the Centers for Disease Control and Prevention’s HIV testing recommendations. PMID:21689041
Evaluation of replacement thread lubricants for red lead and graphite in mineral oil
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jungling, T.L.; Rauth, D.R.; Goldberg, D.
1998-04-30
Eight commercially available thread lubricants were evaluated to determine the best replacement for Red Lead and Graphite in Mineral Oil (RLGMO). The evaluation included coefficient of friction testing, high temperature anti-seizing testing, room temperature anti-galling testing, chemical analysis for detrimental impurities, corrosion testing, off-gas testing, and a review of health and environmental factors. The coefficient of friction testing covered a wide variety of factors including stud, nut, and washer materials, sizes, manufacturing methods, surface coatings, surface finishes, applied loads, run-in cycles, and relubrication. Only one lubricant, Dow Corning Molykote P37, met all the criteria established for a replacement lubricant. Itmore » has a coefficient of friction range similar to RLGMO. Therefore, it can be substituted directly for RLGMO without changing the currently specified fastener torque values for the sizes, materials and conditions evaluated. Other lubricants did not perform as well as Molykote P37 in one or more test or evaluation categories.« less
NASA TEERM Hexavalent Chrome Alternatives Projects
NASA Technical Reports Server (NTRS)
Rothgeb, Matt
2009-01-01
This slide presentation reviews the NASA/DOD projects to select an alternative to hexavalent chrome in the aerospace industry. The Phase I process of the project performed: (1) Evaluation and testing of non-chromated coating systems as replacements for hexavalent chrome coatings in aircraft and aerospace applications. (2) Testing of coating systems to DoD and NASA specifications for corrosion resistance and adhesion. (3) Bare corrosion resistance and atmospheric exposure will be focus areas of Phase II Testing. The description includes a chart that summarizes the 3000 hour salt fog test results. The second phase of the project includes (1) Evaluation and testing of coating systems that do not contain hexavalent chrome as replacements for aerospace applications. (2) Evaluation of coatings at Beach Test Site and Launch Complex 39B (3) Evaluation of non-chrome coatings for electronic housings (bare corrosion resistance and electrical impedance) is a part of this round of testing. This project was performed for the Technology Evaluation for Environmental Risk Mitigation (TEERM)
Detailed Test Plan Redundant Sensor Strapdown IMU Evaluation Program
NASA Technical Reports Server (NTRS)
Hartwell, T.; Miyatake, Y.; Wedekind, D. E.
1971-01-01
The test plan for a redundant sensor strapdown inertial measuring unit evaluation program is presented. The subjects discussed are: (1) test philosophy and limitations, (2) test sequence, (3) equipment specifications, (4) general operating procedures, (5) calibration procedures, (6) alignment test phase, and (7) navigation test phase. The data and analysis requirements are analyzed.
Measuring and Modeling Change in Examinee Effort on Low-Stakes Tests across Testing Occasions
ERIC Educational Resources Information Center
Sessoms, John; Finney, Sara J.
2015-01-01
Because schools worldwide use low-stakes tests to make important decisions, value-added indices computed from test scores must accurately reflect student learning, which requires equal test-taking effort across testing occasions. Evaluating change in effort assumes effort is measured equivalently across occasions. We evaluated the longitudinal…
Crash Tests of Work Zone Traffic Control Devices
DOT National Transportation Integrated Search
1990-02-01
Full-scale vehicle crash tests evaluated performance of typical work zone traffic control devices. Modified test procedures and evaluation criteria from NCHRP Report 230 were used in 108 tests, providing significant insight into impact performance. P...
Specific test and evaluation plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hays, W.H.
1998-03-20
The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made to the 241-AX-B Valve Pit by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation Plan (TEP). Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities), Factory Acceptance Tests (FATs), installation tests and inspections, Construction Acceptance Tests (CATs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), andmore » Operational Test Procedures (OTPs). It should be noted that POTPs are not required for testing of the transfer line addition. The STEP will be utilized in conjunction with the TEP for verification and validation.« less
Interactivity Centered Usability Evaluation (ICUE) for Course Management Systems
ERIC Educational Resources Information Center
Yoon, Sangil
2010-01-01
ICUE (Interactivity Centered Usability Evaluation) is an enhanced usability testing protocol created by the researcher. ICUE augments the facilitator's role for usability testing, and offers strategies in developing and presenting usability tasks during a testing session. ICUE was designed to address weaknesses found in the usability evaluation of…
DOT National Transportation Integrated Search
2010-03-01
Objectives: Evaluate the usefulness of the dynamic modulus and flow number tests in moisture-susceptibility evaluation, Compare the results to those achieved using the AASHTO T 283 test, Study the effect of different methods of sample conditioning an...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Restriction on Ballistic Missile Defense research, development, test, and evaluation. 225.7016 Section 225.7016 Federal Acquisition... Acquisition 225.7016 Restriction on Ballistic Missile Defense research, development, test, and evaluation. [68...
40 CFR 230.61 - Chemical, biological, and physical evaluation and testing.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Chemical, biological, and physical... FILL MATERIAL Evaluation and Testing § 230.61 Chemical, biological, and physical evaluation and testing... approaches or procedures will be furnished by the permitting authority. (b) Chemical-biological interactive...
46 CFR 133.40 - Evaluation, testing and approval of lifesaving appliances and arrangements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Evaluation, testing and approval of lifesaving appliances and arrangements. 133.40 Section 133.40 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS LIFESAVING SYSTEMS General § 133.40 Evaluation, testing and approval of...
46 CFR 133.40 - Evaluation, testing and approval of lifesaving appliances and arrangements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Evaluation, testing and approval of lifesaving appliances and arrangements. 133.40 Section 133.40 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS LIFESAVING SYSTEMS General § 133.40 Evaluation, testing and approval of...
DOT National Transportation Integrated Search
1999-03-01
This report provides an overview of both the Anaheim Advanced Traffic Control System Field Operations Test (FOT) and of the technical issues associated with the evaluation of SCOOT performance during the test. The primary objective of the FOT was to ...
30 CFR 14.3 - Observers at tests and evaluations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Observers at tests and evaluations. 14.3 Section 14.3 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS REQUIREMENTS FOR THE APPROVAL OF FLAME-RESISTANT CONVEYOR BELTS...
NASA Technical Reports Server (NTRS)
Szuch, J. R.; Soeder, J. F.; Seldner, K.; Cwynar, D. S.
1977-01-01
The design, evaluation, and testing of a practical, multivariable, linear quadratic regulator control for the F100 turbofan engine were accomplished. NASA evaluation of the multivariable control logic and implementation are covered. The evaluation utilized a real time, hybrid computer simulation of the engine. Results of the evaluation are presented, and recommendations concerning future engine testing of the control are made. Results indicated that the engine testing of the control should be conducted as planned.
Testing For EM Upsets In Aircraft Control Computers
NASA Technical Reports Server (NTRS)
Belcastro, Celeste M.
1994-01-01
Effects of transient electrical signals evaluated in laboratory tests. Method of evaluating nominally fault-tolerant, aircraft-type digital-computer-based control system devised. Provides for evaluation of susceptibility of system to upset and evaluation of integrity of control when system subjected to transient electrical signals like those induced by electromagnetic (EM) source, in this case lightning. Beyond aerospace applications, fault-tolerant control systems becoming more wide-spread in industry; such as in automobiles. Method supports practical, systematic tests for evaluation of designs of fault-tolerant control systems.
Sea Level Operation Demonstration of F404-GE-400 Turbofan Engine with JP-5/Bio-Fuel Mixture
2010-03-30
Aircraft Test and Evaluation Facility Hush House at Naval Air Station Patuxent River, Maryland, on 13 October 2009. The test consisted of two separate...turbofan engine inside the Aircraft Test and Evaluation Facility Hush House at Naval Air Station Patuxent River, Maryland, on 13 October 2009. The test...turbofan engine (ESN 310810) inside the Aircraft Test and Evaluation Facility Hush House at Naval Air Station (NAS) Patuxent River, Maryland, on 13
NASA Technical Reports Server (NTRS)
Aaronson, A. C.; Buelow, K.; David, F. C.; Packard, R. L.; Ravet, F. W. (Principal Investigator)
1979-01-01
The latest satellite and computer processing and analysis technologies were tested and evaluated in terms of their application feasibility. Technologies evaluated include those developed, tested, and evaluated by the LACIE, as well as candidate technologies developed by the research community and private industry. The implementation of the applications test system and the technology transfer experience between the LACIE and the applications test system is discussed highlighting the approach, the achievements, and the shortcomings.
Test and evaluation procedures for Sandia's Teraflops Operating System (TOS) on Janus.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnette, Daniel Wayne
This report describes the test and evaluation methods by which the Teraflops Operating System, or TOS, that resides on Sandia's massively-parallel computer Janus is verified for production release. Also discussed are methods used to build TOS before testing and evaluating, miscellaneous utility scripts, a sample test plan, and a proposed post-test method for quickly examining the large number of test results. The purpose of the report is threefold: (1) to provide a guide to T&E procedures, (2) to aid and guide others who will run T&E procedures on the new ASCI Red Storm machine, and (3) to document some ofmore » the history of evaluation and testing of TOS. This report is not intended to serve as an exhaustive manual for testers to conduct T&E procedures.« less
DOT National Transportation Integrated Search
1999-09-01
This report presents the results of the field test portion of the Development, Evaluation, and Application of Performance-Based Brake Testing Technologies sponsored by the Federal Highway Administrations (FHWA) Office of Motor Carriers.
Systematic evaluation of non-animal test methods for skin sensitisation safety assessment.
Reisinger, Kerstin; Hoffmann, Sebastian; Alépée, Nathalie; Ashikaga, Takao; Barroso, Joao; Elcombe, Cliff; Gellatly, Nicola; Galbiati, Valentina; Gibbs, Susan; Groux, Hervé; Hibatallah, Jalila; Keller, Donald; Kern, Petra; Klaric, Martina; Kolle, Susanne; Kuehnl, Jochen; Lambrechts, Nathalie; Lindstedt, Malin; Millet, Marion; Martinozzi-Teissier, Silvia; Natsch, Andreas; Petersohn, Dirk; Pike, Ian; Sakaguchi, Hitoshi; Schepky, Andreas; Tailhardat, Magalie; Templier, Marie; van Vliet, Erwin; Maxwell, Gavin
2015-02-01
The need for non-animal data to assess skin sensitisation properties of substances, especially cosmetics ingredients, has spawned the development of many in vitro methods. As it is widely believed that no single method can provide a solution, the Cosmetics Europe Skin Tolerance Task Force has defined a three-phase framework for the development of a non-animal testing strategy for skin sensitization potency prediction. The results of the first phase – systematic evaluation of 16 test methods – are presented here. This evaluation involved generation of data on a common set of ten substances in all methods and systematic collation of information including the level of standardisation, existing test data,potential for throughput, transferability and accessibility in cooperation with the test method developers.A workshop was held with the test method developers to review the outcome of this evaluation and to discuss the results. The evaluation informed the prioritisation of test methods for the next phase of the non-animal testing strategy development framework. Ultimately, the testing strategy – combined with bioavailability and skin metabolism data and exposure consideration – is envisaged to allow establishment of a data integration approach for skin sensitisation safety assessment of cosmetic ingredients.
NASA Technical Reports Server (NTRS)
Murphy, Kenneth S.; Castro, Joaquin H.
1988-01-01
The activity performed on the screening and evaluation of various coatings for application on columbium alloy test panels representative of a radiation-cooled nozzle extension for the RL10 rocket engine is summarized. Vendors and processes of candidate coatings were evaluated. Post engine test evaluations of the two selected coatings are discussed.
Robert J. Ross; Xiping Wang
2012-01-01
The International Nondestructive Testing and Evaluation of Wood Symposium Series was initiated by Washington State University and the USDA Forest Products Laboratory (FPL) in 1963 with the convening of a symposium on the topic of nondestructive testing of wood at FPL. Including that meeting, 17 symposia have been held during the last 50 years at various sites around...
Validation and Verification (V and V) Testing on Midscale Flame Resistant (FR) Test Method
2016-12-16
Method for Evaluation of Flame Resistant Clothing for Protection against Fire Simulations Using an Instrumented Manikin. Validation and...complement (not replace) the capabilities of the ASTM F1930 Standard Test Method for Evaluation of Flame Resistant Clothing for Protection against Fire ...Engineering Center (NSRDEC) to complement the ASTM F1930 Standard Test Method for Evaluation of Flame Resistant Clothing for Protection against Fire
Evaluating Content Alignment in Computerized Adaptive Testing
ERIC Educational Resources Information Center
Wise, Steven L.; Kingsbury, G. Gage; Webb, Norman L.
2015-01-01
The alignment between a test and the content domain it measures represents key evidence for the validation of test score inferences. Although procedures have been developed for evaluating the content alignment of linear tests, these procedures are not readily applicable to computerized adaptive tests (CATs), which require large item pools and do…
DOT National Transportation Integrated Search
2015-06-01
For years, the Kansas Department of Transportation (KDOT) and concrete producers in the state have used a : Rapid Chloride Test for concrete cylinders, AASHTO T277. This test has been thought of as an appropriate quality : control test to evaluate pe...
Gonzalez-Neira, Eliana Maria; Jimenez-Mendoza, Claudia Patricia; Rugeles-Quintero, Saul
2016-01-01
Objective: This study aims at determining if a collection of 16 motor tests on a physical simulator can objectively discriminate and evaluate practitioners' competency level, i.e. novice, resident, and expert. Methods: An experimental design with three study groups (novice, resident, and expert) was developed to test the evaluation power of each of the 16 simple tests. An ANOVA and a Student Newman-Keuls (SNK) test were used to analyze results of each test to determine which of them can discriminate participants' competency level. Results: Four of the 16 tests used discriminated all of the three competency levels and 15 discriminated at least two of the three groups (α= 0.05). Moreover, other two tests differentiate beginners' level from intermediate, and other seven tests differentiate intermediate level from expert. Conclusion: The competency level of a practitioner of minimally invasive surgery can be evaluated by a specific collection of basic tests in a physical surgical simulator. Reduction of the number of tests needed to discriminate the competency level of surgeons can be the aim of future research. PMID:27226664
A multi‐centre evaluation of nine rapid, point‐of‐care syphilis tests using archived sera
Herring, A J; Ballard, R C; Pope, V; Adegbola, R A; Changalucha, J; Fitzgerald, D W; Hook, E W; Kubanova, A; Mananwatte, S; Pape, J W; Sturm, A W; West, B; Yin, Y P; Peeling, R W
2006-01-01
Objectives To evaluate nine rapid syphilis tests at eight geographically diverse laboratory sites for their performance and operational characteristics. Methods Tests were compared “head to head” using locally assembled panels of 100 archived (50 positive and 50 negative) sera at each site using as reference standards the Treponema pallidum haemagglutination or the T pallidum particle agglutination test. In addition inter‐site variation, result stability, test reproducibility and test operational characteristics were assessed. Results All nine tests gave good performance relative to the reference standard with sensitivities ranging from 84.5–97.7% and specificities from 84.5–98%. Result stability was variable if result reading was delayed past the recommended period. All the tests were found to be easy to use, especially the lateral flow tests. Conclusions All the tests evaluated have acceptable performance characteristics and could make an impact on the control of syphilis. Tests that can use whole blood and do not require refrigeration were selected for further evaluation in field settings. PMID:17118953
Gonzalez-Neira, Eliana Maria; Jimenez-Mendoza, Claudia Patricia; Suarez, Daniel R; Rugeles-Quintero, Saul
2016-03-30
This study aims at determining if a collection of 16 motor tests on a physical simulator can objectively discriminate and evaluate practitioners' competency level, i.e. novice, resident, and expert. An experimental design with three study groups (novice, resident, and expert) was developed to test the evaluation power of each of the 16 simple tests. An ANOVA and a Student Newman-Keuls (SNK) test were used to analyze results of each test to determine which of them can discriminate participants' competency level. Four of the 16 tests used discriminated all of the three competency levels and 15 discriminated at least two of the three groups (α= 0.05). Moreover, other two tests differentiate beginners' level from intermediate, and other seven tests differentiate intermediate level from expert. The competency level of a practitioner of minimally invasive surgery can be evaluated by a specific collection of basic tests in a physical surgical simulator. Reduction of the number of tests needed to discriminate the competency level of surgeons can be the aim of future research.
Collaborative Testing: An Effective Invitational Strategy for High-Stakes Testing in Nursing.
Green, Rebecca; Worthey, Terri; Kerven, Jenny
2018-05-01
A collaborative testing intervention was designed as an application of the invitational education model in an undergraduate nursing course. The purpose of this study was to evaluate the effect of collaborative testing on examination scores and knowledge retention of course content and to evaluate students' feelings about the collaborative testing process. A quasi-experimental design was used to evaluate the effect of collaborative testing on examination scores and knowledge retention among undergraduate nursing students in a public health course (N = 106). A descriptive survey was used to evaluate students' perceptions of the collaborative testing intervention. Collaborative testing increased examination scores and facilitated knowledge retention. Students' perceptions of the intervention were positive. Invitational strategies, such as collaborative testing, may result in measurably better outcomes, such as better examination scores and improved knowledge retention. Rigor does not need to be a barrier to invitational learning and, in fact, it may be complemented and enhanced by it. [J Nurs Educ. 2018;57(5):291-295.]. Copyright 2018, SLACK Incorporated.
Technical Evaluation Motor No. 7 (TEM-07)
NASA Technical Reports Server (NTRS)
Hugh, Phil
1991-01-01
Technical Evaluation Motor Number 7 (TEM-7) was a full scale, full-duration static test firing of a high performance motor (HPM) configuration solid rocket motor (SRM) with nozzle vectoring. The static test fire occurred on 11 December 1990 at the Thiokol Corporation Static Test Bay T-97. Documented here are the procedures, performance, and results available through 22 January 1991. Critical post test hardware activities and assessment of the test data are not complete. A completed test report will be submitted 60 days after the test date. Included here is a presentation and discussion of the TEM-7 performance, anomalies, and test result concurrence with the objectives outlined in CTP-0107 Revision A, Space Shuttle Technical Evaluation Motor number 7 (TEM-07) Static Fire Test Plan.
Prado, Elizabeth L; Hartini, Sri; Rahmawati, Atik; Ismayani, Elfa; Hidayati, Astri; Hikmah, Nurul; Muadz, Husni; Apriatni, Mandri S; Ullman, Michael T; Shankar, Anuraj H; Alcock, Katherine J
2010-03-01
Evaluating the impact of nutrition interventions on developmental outcomes in developing countries can be challenging since most assessment tests have been produced in and for developed country settings. Such tests may not be valid measures of children's abilities when used in a new context. We present several principles for the selection, adaptation, and evaluation of tests assessing the developmental outcomes of nutrition interventions in developing countries where standard assessment tests do not exist. We then report the application of these principles for a nutrition trial on the Indonesian island of Lombok. Three hundred children age 22-55 months in Lombok participated in a series of pilot tests for the purpose of test adaptation and evaluation. Four hundred and eighty-seven 42-month-old children in Lombok were tested on the finalized test battery. The developmental assessment tests were adapted to the local context and evaluated for a number of psychometric properties, including convergent and discriminant validity, which were measured based on multiple regression models with maternal education, depression, and age predicting each test score. The adapted tests demonstrated satisfactory psychometric properties and the expected pattern of relationships with the three maternal variables. Maternal education significantly predicted all scores but one, maternal depression predicted socio-emotional competence, socio-emotional problems, and vocabulary, while maternal age predicted socio-emotional competence only. Following the methodological principles we present resulted in tests that were appropriate for children in Lombok and informative for evaluating the developmental outcomes of nutritional supplementation in the research context. Following this approach in future studies will help to determine which interventions most effectively improve child development in developing countries.
Using a fuzzy comprehensive evaluation method to determine product usability: A test case
Zhou, Ronggang; Chan, Alan H. S.
2016-01-01
BACKGROUND: In order to take into account the inherent uncertainties during product usability evaluation, Zhou and Chan [1] proposed a comprehensive method of usability evaluation for products by combining the analytic hierarchy process (AHP) and fuzzy evaluation methods for synthesizing performance data and subjective response data. This method was designed to provide an integrated framework combining the inevitable vague judgments from the multiple stages of the product evaluation process. OBJECTIVE AND METHODS: In order to illustrate the effectiveness of the model, this study used a summative usability test case to assess the application and strength of the general fuzzy usability framework. To test the proposed fuzzy usability evaluation framework [1], a standard summative usability test was conducted to benchmark the overall usability of a specific network management software. Based on the test data, the fuzzy method was applied to incorporate both the usability scores and uncertainties involved in the multiple components of the evaluation. Then, with Monte Carlo simulation procedures, confidence intervals were used to compare the reliabilities among the fuzzy approach and two typical conventional methods combining metrics based on percentages. RESULTS AND CONCLUSIONS: This case study showed that the fuzzy evaluation technique can be applied successfully for combining summative usability testing data to achieve an overall usability quality for the network software evaluated. Greater differences of confidence interval widths between the method of averaging equally percentage and weighted evaluation method, including the method of weighted percentage averages, verified the strength of the fuzzy method. PMID:28035942
Using a fuzzy comprehensive evaluation method to determine product usability: A test case.
Zhou, Ronggang; Chan, Alan H S
2017-01-01
In order to take into account the inherent uncertainties during product usability evaluation, Zhou and Chan [1] proposed a comprehensive method of usability evaluation for products by combining the analytic hierarchy process (AHP) and fuzzy evaluation methods for synthesizing performance data and subjective response data. This method was designed to provide an integrated framework combining the inevitable vague judgments from the multiple stages of the product evaluation process. In order to illustrate the effectiveness of the model, this study used a summative usability test case to assess the application and strength of the general fuzzy usability framework. To test the proposed fuzzy usability evaluation framework [1], a standard summative usability test was conducted to benchmark the overall usability of a specific network management software. Based on the test data, the fuzzy method was applied to incorporate both the usability scores and uncertainties involved in the multiple components of the evaluation. Then, with Monte Carlo simulation procedures, confidence intervals were used to compare the reliabilities among the fuzzy approach and two typical conventional methods combining metrics based on percentages. This case study showed that the fuzzy evaluation technique can be applied successfully for combining summative usability testing data to achieve an overall usability quality for the network software evaluated. Greater differences of confidence interval widths between the method of averaging equally percentage and weighted evaluation method, including the method of weighted percentage averages, verified the strength of the fuzzy method.
Performance evaluation of the solar kinetics T-700 line concentrating solar collector
NASA Technical Reports Server (NTRS)
1981-01-01
A performance evaluation of the solar kinetics T-700 line concentrating solar collector is reported. Collector descriptions, summary, test conditions, test equipment, test requirements and procedures, and an analysis of the various tests performed are described.
The purpose of this issue paper is to address the availability and performance characteristics of portable lead test kits especially suited for lead in paint, procedures for evaluating the performance of these test kits, and the availability of performance evaluation (PE) materia...
38 CFR 4.96 - Special provisions regarding evaluation of respiratory conditions.
Code of Federal Regulations, 2012 CFR
2012-07-01
...-6845. (1) Pulmonary function tests (PFT's) are required to evaluate these conditions except: (i) When the results of a maximum exercise capacity test are of record and are 20 ml/kg/min or less. If a maximum exercise capacity test is not of record, evaluate based on alternative criteria. (ii) When...
This project evaluates a test program of a totally automated weight-based refuse disposal rate system. his test program was conducted by the City of Farmington, Minnesota between 1991 and 1993. he intent of the program was to test a mechanism which would automatically assess a fe...
Bio-Response Operational Testing and Evaluation (BOTE) ...
Report and technical brief and informational video The Bio-response Operational Testing and Evaluation (BOTE) Project was a multi-agency effort designed to operationally test and evaluate, at the scale of a moderately sized building, a response to a B. anthracis spore release from initial public health and law enforcement investigation through environmental remediation.
USDA-ARS?s Scientific Manuscript database
The objective of this work is to evaluate a proposed Test Plan for the validation testing of pesticide spray drift reduction technologies for row and field crops, focusing on the testing of ground and aerial application systems under full-scale field evaluations. The measure of performance for a gi...
Why Is Test-Restudy Practice Beneficial for Memory? An Evaluation of the Mediator Shift Hypothesis
ERIC Educational Resources Information Center
Pyc, Mary A.; Rawson, Katherine A.
2012-01-01
Although the memorial benefits of testing are well established empirically, the mechanisms underlying this benefit are not well understood. The authors evaluated the mediator shift hypothesis, which states that test-restudy practice is beneficial for memory because retrieval failures during practice allow individuals to evaluate the effectiveness…
ERIC Educational Resources Information Center
Patalino, Marianne
Problems in current course evaluation methods are discussed and an alternative method is described for the construction, analysis, and interpretation of a test to evaluate instructional programs. The method presented represents a different approach to the traditional overreliance on standardized achievement tests and the total scores they provide.…
An evaluation of the hemiplegic subject based on the Bobath approach. Part III. A validation study.
Arsenault, A B; Dutil, E; Lambert, J; Corriveau, H; Guarna, F; Drouin, G
1988-01-01
Sixty-two hemiplegic subjects were treated with the Bobath approach for a period of three months. During this time they were evaluated on three occasions. The testing battery consisted of a Bobath evaluation, the Brunnstrom scale, the Fugl-Meyer test, the Upper Extremity Functional Test (UEFT) and the Present Pain Intensity (PPI) of the McGill pain questionnaire. A Friedman analysis of variance showed that, except for pain, all the protocols used disclosed significant progress (p less than 0.001) over time in terms of motor recovery. Except for pain, the results of the Bobath evaluation were significantly correlated (Spearman's Rho, p less than 0.001) with the results of the other testing procedures. It is concluded that the new Bobath evaluation proposed in a previous paper is as sensitive in depicting progress in motor recovery over time as are the other testing procedures used. Furthermore, this new evaluation seems to be measuring similar properties to the other tests. However, pain (PPI) appears not to be an important dependent variable.
Senore, Carlo; Mandel, Jack S.; Allison, James E.; Atkin, Wendy S.; Benamouzig, Robert; Bossuyt, Patrick M. M.; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P.; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H.; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A.; O'Morain, Colm A.; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E.; Seaman, Helen E.; Steele, Robert J. C.; Sung, Joseph J. Y.; Winawer, Sidney J.
2016-01-01
BACKGROUND New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. METHODS A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. RESULTS Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention‐to‐screen basis, including acceptability, is essential. Cancer‐specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac‐based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4‐phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention‐to‐screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true‐positive and false‐positive rates, and the number needed to colonoscope to detect a target lesion. CONCLUSIONS New screening tests can be evaluated efficiently by this stepwise comparative approach. Cancer 2016;122:826–39. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society. PMID:26828588
Young, Graeme P; Senore, Carlo; Mandel, Jack S; Allison, James E; Atkin, Wendy S; Benamouzig, Robert; Bossuyt, Patrick M M; Silva, Mahinda De; Guittet, Lydia; Halloran, Stephen P; Haug, Ulrike; Hoff, Geir; Itzkowitz, Steven H; Leja, Marcis; Levin, Bernard; Meijer, Gerrit A; O'Morain, Colm A; Parry, Susan; Rabeneck, Linda; Rozen, Paul; Saito, Hiroshi; Schoen, Robert E; Seaman, Helen E; Steele, Robert J C; Sung, Joseph J Y; Winawer, Sidney J
2016-03-15
New screening tests for colorectal cancer continue to emerge, but the evidence needed to justify their adoption in screening programs remains uncertain. A review of the literature and a consensus approach by experts was undertaken to provide practical guidance on how to compare new screening tests with proven screening tests. Findings and recommendations from the review included the following: Adoption of a new screening test requires evidence of effectiveness relative to a proven comparator test. Clinical accuracy supported by programmatic population evaluation in the screening context on an intention-to-screen basis, including acceptability, is essential. Cancer-specific mortality is not essential as an endpoint provided that the mortality benefit of the comparator has been demonstrated and that the biologic basis of detection is similar. Effectiveness of the guaiac-based fecal occult blood test provides the minimum standard to be achieved by a new test. A 4-phase evaluation is recommended. An initial retrospective evaluation in cancer cases and controls (Phase 1) is followed by a prospective evaluation of performance across the continuum of neoplastic lesions (Phase 2). Phase 3 follows the demonstration of adequate accuracy in these 2 prescreening phases and addresses programmatic outcomes at 1 screening round on an intention-to-screen basis. Phase 4 involves more comprehensive evaluation of ongoing screening over multiple rounds. Key information is provided from the following parameters: the test positivity rate in a screening population, the true-positive and false-positive rates, and the number needed to colonoscope to detect a target lesion. New screening tests can be evaluated efficiently by this stepwise comparative approach. © 2016 The Authors. Cancer published by Wiley Periodicals, Inc. on behalf of American Cancer Society.
Summary of sensor evaluation for the Fusion Electromagnetic Induction Experiment (FELIX)
NASA Astrophysics Data System (ADS)
Knott, M. J.
1982-08-01
As part of the First Wall/Blanket/Shield Engineering Test Program, a test bed called FELIX (fusion electromagnetic induction experiment) is under construction. Its purpose is to test, evaluate, and develop computer codes for the prediction of electromagnetically induced phenomenon in a magnetic environment modeling that of a fusion reaction. Crucial to this process is the sensing and recording of the various induced effects. Sensor evaluation for FELIX reached the point where most sensor types were evaluated and preliminary decisions are being made as to type and quantity for the initial FELIX experiments. These early experiments, the first, flat plate experiment in particular, will be aimed at testing the sensors as well as the pertinent theories involved. The reason for these evaluations, decisions, and proof tests is the harsh electrical and magnetic environment that FELIX presents.
Fox, Stephanie J; Park, Miguel A
2014-01-01
Penicillin skin testing has been validated in the evaluation of adult patients with penicillin allergy. However, the commercially available benzylpenicilloyl polylysine (Pre-Pen) is not indicated in the pediatric population. Moreover, the safety and validity of penicillin skin testing in the pediatric population has not been well studied. We describe the safety and validity of penicillin skin testing in the evaluation of children with a history of penicillin allergy. Children (<18 years) with a history of penicillin allergy were evaluated with penicillin skin tests and were reviewed for basic demographics, penicillin skin test results, adverse drug reaction to penicillin after penicillin skin test, and adverse reaction to penicillin skin test. By using the χ(2) test, we compared the differences in the proportion of children and adults with a positive penicillin skin test. P value (<.05) was considered statistically significant. The institutional review board approved the study, and all the subjects signed written informed consents. A total of 778 children underwent penicillin skin testing; 703 of 778 patients had a negative penicillin skin test (90.4%), 66 had a positive test (8.5%), and 9 had an equivocal test (1.1%). Children were more likely to have a positive penicillin skin test (P < .0001) compared with adults (64 of 1759 [3.6%]); 369 of 703 patients with negative penicillin skin test (52%) were challenged with penicillin, and 14 of 369 patients (3.8%) had an adverse drug reaction. No adverse reactions to penicillin skin testing were observed. Penicillin skin testing was safe and effective in the evaluation of children with a history of penicillin allergy. Copyright © 2014 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Methods Used in Economic Evaluations of Chronic Kidney Disease Testing — A Systematic Review
Sutton, Andrew J.; Breheny, Katie; Deeks, Jon; Khunti, Kamlesh; Sharpe, Claire; Ottridge, Ryan S.; Stevens, Paul E.; Cockwell, Paul; Kalra, Philp A.; Lamb, Edmund J.
2015-01-01
Background The prevalence of chronic kidney disease (CKD) is high in general populations around the world. Targeted testing and screening for CKD are often conducted to help identify individuals that may benefit from treatment to ameliorate or prevent their disease progression. Aims This systematic review examines the methods used in economic evaluations of testing and screening in CKD, with a particular focus on whether test accuracy has been considered, and how analysis has incorporated issues that may be important to the patient, such as the impact of testing on quality of life and the costs they incur. Methods Articles that described model-based economic evaluations of patient testing interventions focused on CKD were identified through the searching of electronic databases and the hand searching of the bibliographies of the included studies. Results The initial electronic searches identified 2,671 papers of which 21 were included in the final review. Eighteen studies focused on proteinuria, three evaluated glomerular filtration rate testing and one included both tests. The full impact of inaccurate test results was frequently not considered in economic evaluations in this setting as a societal perspective was rarely adopted. The impact of false positive tests on patients in terms of the costs incurred in re-attending for repeat testing, and the anxiety associated with a positive test was almost always overlooked. In one study where the impact of a false positive test on patient quality of life was examined in sensitivity analysis, it had a significant impact on the conclusions drawn from the model. Conclusion Future economic evaluations of kidney function testing should examine testing and monitoring pathways from the perspective of patients, to ensure that issues that are important to patients, such as the possibility of inaccurate test results, are properly considered in the analysis. PMID:26465773
The Evaluation of Carpet Steam/Heat Cleaners as Biological Sampling Device
2011-12-08
Vacuum Cleaner Evaluation as sampling Device Test Plan DHS Page 16 of 16 Fumigants , and Issues Related to Laboratory-scale Studies. Appl. Environ...ECBC Wet/dry Vacuum Cleaner Evaluation as sampling Device Test Plan DHS Page 1 of 16 Test Plan for The Evaluation of Carpet Steam...b. ABSTRACT unclassified c. THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 ECBC Wet/dry Vacuum Cleaner
An Analysis of Rocket Propulsion Testing Costs
NASA Technical Reports Server (NTRS)
Ramirez, Carmen; Rahman, Shamim
2010-01-01
The primary mission at NASA Stennis Space Center (SSC) is rocket propulsion testing. Such testing is commonly characterized as one of two types: production testing for certification and acceptance of engine hardware, and developmental testing for prototype evaluation or research and development (R&D) purposes. For programmatic reasons there is a continuing need to assess and evaluate the test costs for the various types of test campaigns that involve liquid rocket propellant test articles. Presently, in fact, there is a critical need to provide guidance on what represents a best value for testing and provide some key economic insights for decision-makers within NASA and the test customers outside the Agency. Hence, selected rocket propulsion test databases and references have been evaluated and analyzed with the intent to discover correlations of technical information and test costs that could help produce more reliable and accurate cost projections in the future. The process of searching, collecting, and validating propulsion test cost information presented some unique obstacles which then led to a set of recommendations for improvement in order to facilitate future cost information gathering and analysis. In summary, this historical account and evaluation of rocket propulsion test cost information will enhance understanding of the various kinds of project cost information; identify certain trends of interest to the aerospace testing community.
1986-10-01
opeational test and evaluation (OT&R). The OT&B Is comprised of Initial operational test and evaluation ( IOT &R) and follow-on test and evaluation (FOT&R). OT&I...BP HYL FVAC beating, ventilation and air conditioning am. ICBM Intercntinental ballistic missile an. IOT &R Initial operational test and *valuation so...and maintenance vehicles (stop- B pod, engine idle-exterior), facility equipment utility rooms, heating, ventilation and air conditioning ( HVAC
1997-08-01
AL/EQ-TR-1997-0050 DEVELOPMENT AND EVALUATION OF REPRODUCTIVE AND DEVELOPMENT TOXICITY TESTS FOR ASSESSING THE HAZARDS OF ENVIRONMENTAL...SUBTITLE Development and Evaluation of Reproductive and Developmental Toxicity Tests for Assessing the Hazards of Environmental Contaminants 6...pd in testing toxicity in surface waters, ground waters and H- ™t™j£J^^^M hazard assessment when used in conjunction in sediments. FETAX can be usea
Air Force Human Systems Integration (HSI) in Test and Evaluation (T&E)
2012-08-01
allow human aspects related to system design to be tested and evaluated. 15. SUBJECT TERMS Air Force, Human Systems Integration, HSI, Test and...Community that would allow human aspects related to system design to be tested and evaluated. The intent was to identify and develop means for greater...related documentation in order to monitor the human related aspects for system development and design . To address these work areas, the team adopted
NASA Technical Reports Server (NTRS)
Slater, Richard
1996-01-01
A joint U.S./Russian film test was conducted during MIR Mission 18 to evaluate the effects of radiation on photographic film during long-duration space flights. Two duplicate sets of film were flown on this MIR mission: one set was processed and evaluated by the NASA/JSC Photographic Laboratory, and the other by the RKK Energia's Photographic Laboratory in Moscow. This preliminary report includes only the results of the JSC evaluation (excluding the SN-10 film which was not available for evaluation at the time this report was written). The final report will include an evaluation by JSC of the SN-10 film and an evaluation of the test data by the RKK Energia. ISC's evaluation of the test data showed the positive film flown was damaged very little when exposed to approximately 8 rads of radiation. Two of the three negative films were significantly damaged and the third film was damaged only moderately.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slater, R.
1996-04-01
A joint U.S./Russian film test was conducted during MIR Mission 18 to evaluate the effects of radiation on photographic film during long-duration space flights. Two duplicate sets of film were flown on this MIR mission: one set was processed and evaluated by the NASA/JSC Photographic Laboratory, and the other by the RKK Energia`s Photographic Laboratory in Moscow. This preliminary report includes only the results of the JSC evaluation (excluding the SN-10 film which was not available for evaluation at the time this report was written). The final report will include an evaluation by JSC of the SN-10 film and anmore » evaluation of the test data by the RKK Energia. ISC`s evaluation of the test data showed the positive film flown was damaged very little when exposed to approximately 8 rads of radiation. Two of the three negative films were significantly damaged and the third film was damaged only moderately.« less
DOT National Transportation Integrated Search
2003-09-22
This document presents the Evaluation Teams plan for conducting the evaluation of the FOT in Washington State. A companion document exists for the evaluation of the Utah deployment. This plan includes the experimental design for testing hypotheses...
DOT National Transportation Integrated Search
1998-07-01
The purpose of the independent evaluation is to assess the effectiveness of the FORETELL Program in achieving certain ARTS goals and objectives. Independent evaluations of ITS Operational Tests require a well documented structured approach to ensure ...
Evaluation of Variability in Resilient Modulus Test Results (ASTM D4123)
DOT National Transportation Integrated Search
1989-10-01
Samples of asphalt mixture were evaluated in the laboratory under various conditions to evaluate the repeatability of the resilient modulus test and to evaluate the effect of stress on the measured resilient modulus. Some of the samples were prepared...
Evaluation plan for space station network interface units
NASA Technical Reports Server (NTRS)
Weaver, Alfred C.
1990-01-01
Outlined here is a procedure for evaluating network interface units (NIUs) produced for the Space Station program. The procedures should be equally applicable to the data management system (DMS) testbed NIUs produced by Honeywell and IBM. The evaluation procedures are divided into four areas. Performance measurement tools are hardware and software that must be developed in order to evaluate NIU performance. Performance tests are a series of tests, each of which documents some specific characteristic of NIU and/or network performance. In general, these performance tests quantify the speed, capacity, latency, and reliability of message transmission under a wide variety of conditions. Functionality tests are a series of tests and code inspections that demonstrate the functionality of the particular subset of ISO protocols which have been implemented in a given NIU. Conformance tests are a series of tests which would expose whether or not selected features within the ISO protocols are present and interoperable.
Galuschka, Katharina; Rothe, Josefine; Schulte-Körne, Gerd
2015-09-01
This article looks at a means of objectively evaluating the quality of psychometric tests. This approach enables users to evaluate psychometric tests based on their methodological characteristics, in order to decide which instrument should be used. Reading and spelling assessment tools serve as examples. The paper also provides a review of German psychometric tests for the assessment of reading and spelling skills. This method facilitates the identification of psychometric tests.of high methodological quality which can be used for the assessment of reading and spelling skills. Reading performance should ideally be assessed with the following instruments: ELFE 1-6, LGVT 6-12, LESEN 6-7, LESEN 8-9, or WLLP-R. The tests to be used for the evaluation of spelling skills are DERET 1-2+, DERET 3-4+, WRT 1+, WRT 2+, WRT 3+, WRT 4+ or HSP 1-10.
Refractory Metal Heat Pipe Life Test - Test Plan and Standard Operating Procedures
NASA Technical Reports Server (NTRS)
Martin, J. J.; Reid, R. S.
2010-01-01
Refractory metal heat pipes developed during this project shall be subjected to various operating conditions to evaluate life-limiting corrosion factors. To accomplish this objective, various parameters shall be investigated, including the effect of temperature and mass fluence on long-term corrosion rate. The test series will begin with a performance test of one module to evaluate its performance and to establish the temperature and power settings for the remaining modules. The performance test will be followed by round-the-clock testing of 16 heat pipes. All heat pipes shall be nondestructively inspected at 6-month intervals. At longer intervals, specific modules will be destructively evaluated. Both the nondestructive and destructive evaluations shall be coordinated with Los Alamos National Laboratory. During the processing, setup, and testing of the heat pipes, standard operating procedures shall be developed. Initial procedures are listed here and, as hardware is developed, will be updated, incorporating findings and lessons learned.
40 CFR 86.1829-01 - Durability and emission testing requirements; waivers.
Code of Federal Regulations, 2012 CFR
2012-07-01
... manufacturer's engineering evaluation of appropriate high-altitude emission testing, all light-duty vehicles..., development tests, or other appropriate information and good engineering judgment. (2) Evaporative/Refueling... manufacturer's engineering evaluation of appropriate testing and/or design parameters, all light-duty vehicles...
Shinkins, Bethany; Yang, Yaling; Abel, Lucy; Fanshawe, Thomas R
2017-04-14
Evaluations of diagnostic tests are challenging because of the indirect nature of their impact on patient outcomes. Model-based health economic evaluations of tests allow different types of evidence from various sources to be incorporated and enable cost-effectiveness estimates to be made beyond the duration of available study data. To parameterize a health-economic model fully, all the ways a test impacts on patient health must be quantified, including but not limited to diagnostic test accuracy. We assessed all UK NIHR HTA reports published May 2009-July 2015. Reports were included if they evaluated a diagnostic test, included a model-based health economic evaluation and included a systematic review and meta-analysis of test accuracy. From each eligible report we extracted information on the following topics: 1) what evidence aside from test accuracy was searched for and synthesised, 2) which methods were used to synthesise test accuracy evidence and how did the results inform the economic model, 3) how/whether threshold effects were explored, 4) how the potential dependency between multiple tests in a pathway was accounted for, and 5) for evaluations of tests targeted at the primary care setting, how evidence from differing healthcare settings was incorporated. The bivariate or HSROC model was implemented in 20/22 reports that met all inclusion criteria. Test accuracy data for health economic modelling was obtained from meta-analyses completely in four reports, partially in fourteen reports and not at all in four reports. Only 2/7 reports that used a quantitative test gave clear threshold recommendations. All 22 reports explored the effect of uncertainty in accuracy parameters but most of those that used multiple tests did not allow for dependence between test results. 7/22 tests were potentially suitable for primary care but the majority found limited evidence on test accuracy in primary care settings. The uptake of appropriate meta-analysis methods for synthesising evidence on diagnostic test accuracy in UK NIHR HTAs has improved in recent years. Future research should focus on other evidence requirements for cost-effectiveness assessment, threshold effects for quantitative tests and the impact of multiple diagnostic tests.
Test Item Analysis: An Educator Professionalism Approach
ERIC Educational Resources Information Center
Hamzah, Mohd Sahandri Gani; Abdullah, Saifuddin Kumar
2011-01-01
The evaluation of learning is a systematic process involving testing, measuring and evaluation. In the testing step, a teacher needs to choose the best instrument that can test the minds of students. Testing will produce scores or marks with many variations either in homogeneous or heterogeneous forms that will be used to categorize the scores…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-13
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Evaluation of In Vitro Tests for Identifying Eye Injury...-animal testing strategies proposed for identifying eye injury hazard potential of chemicals and products... Panel and submission of data from substances tested in in vitro tests for identifying eye injury hazard...
DOT National Transportation Integrated Search
2015-06-01
For years, the Kansas Department of Transportation (KDOT) and concrete producers in : the state have used a Rapid Chloride Test for concrete cylinders, AASHTO T277. This : test has been thought of as an appropriate quality control test to evaluate pe...
Genotoxicity evaluation of So-ochim-tang-gamibang (SOCG), a herbal medicine.
Lee, Mi Young; Park, Yang-Chun; Jin, Mirim; Kim, Eunseok; Choi, Jeong June; Jung, In Chul
2018-02-02
So-ochim-tang-gamibang (SOCG) is a traditional Korean medicine frequently used for depression in the clinical field. In this study, we evaluated the potential genotoxicity of SOCG using three standard batteries of tests as part of a safety evaluation. SOCG was evaluated for potential genotoxic effects using the standard three tests recommended by the Ministry of Food and Drug Safety (MFDS) of Korea. These tests were the bacterial reverse mutation test (Ames test), in vitro mammalian chromosomal aberration test using Chinese hamster lung cells, and in vivo micronucleus test using ICR mice. The Ames test with Salmonella typhimurium strains TA98, TA100, TA1535 and TA1537 and the Escherichia coli strain WP2uvrA(pKM101) showed that SOCG did not induce gene mutations at any dose level in all of the strains. SOCG did not induce any chromosomal aberrations in the in vitro chromosomal aberration test (for both the 6 and 24 h test) and the in vivo micronucleus test. Based on the results of these tests, it was concluded that SOCG does not exhibit any genotoxic risk under the experimental conditions of this study.
Technical Evaluation Motor No. 10 (TEM-10)
NASA Technical Reports Server (NTRS)
1993-01-01
Technical Evaluation Motor No. 10 (TEM-10) was static fired on 27 Apr. 1993 at the Thiokol Corporation full-scale motor static test bay, T-24. This final test report documents the procedures, performance, and results of the static test firing of TEM-10. All observations, discussions, conclusions, and recommendations contained are final. Included is a presentation and discussion of TEM-10 performance, anomalies, and test results in concurrence with the objectives outlined in CTP-0110, Revision D, Space Shuttle Technical Evaluation Motor No. 10 (TEM-10) Static Fire Test Plan.
[Magnetic resonance compatibility research for coronary mental stents].
Wang, Ying; Liu, Li; Wang, Shuo; Shang, Ruyao; Wang, Chunren
2015-01-01
The objective of this article is to research magnetic resonance compatibility for coronary mental stents, and to evaluate the magnetic resonance compatibility based on laboratory testing results. Coronary stents magnetic resonance compatibility test includes magnetically induced displacement force test, magnetically induced torque test, radio frequency induced heating and evaluation of MR image. By magnetic displacement force and torque values, temperature, and image distortion values to determine metal coronary stent demagnetization effect. The methods can be applied to test magnetic resonance compatibility for coronary mental stents and evaluate its demagnetization effect.
NASA Technical Reports Server (NTRS)
Frickland, P. O.; Repar, J.
1982-01-01
A previously developed test design for accelerated aging of photovoltaic modules was experimentally evaluated. The studies included a review of relevant field experience, environmental chamber cycling of full size modules, and electrical and physical evaluation of the effects of accelerated aging during and after the tests. The test results indicated that thermally induced fatigue of the interconnects was the primary mode of module failure as measured by normalized power output. No chemical change in the silicone encapsulant was detectable after 360 test cycles.
Applying an overstress principle in accelerated testing of absorbing mechanisms
NASA Astrophysics Data System (ADS)
Tsyss, V. G.; Sergaeva, M. Yu; Sergaev, A. A.
2018-04-01
The relevance of using overstress test as a forced one to determine the pneumatic absorber lifespan was studied. The obtained results demonstrated that at low load overstress the relative error for the absorber lifespan evaluation is no more than 3%. This means that the test results spread has almost no effect on the lifespan evaluation, and this effect is several times less than that at high load overstress tests. Accelerated testing of absorbers with low load overstress is more acceptable since the relative error for the lifespan evaluation is negligible.
Armistead-Jehle, Patrick; Cole, Wesley R; Stegman, Robert L
2018-02-01
The study was designed to replicate and extend pervious findings demonstrating the high rates of invalid neuropsychological testing in military service members (SMs) with a history of mild traumatic brain injury (mTBI) assessed in the context of a medical evaluation board (MEB). Two hundred thirty-one active duty SMs (61 of which were undergoing an MEB) underwent neuropsychological assessment. Performance validity (Word Memory Test) and symptom validity (MMPI-2-RF) test data were compared across those evaluated within disability (MEB) and clinical contexts. As with previous studies, there were significantly more individuals in an MEB context that failed performance (MEB = 57%, non-MEB = 31%) and symptom validity testing (MEB = 57%, non-MEB = 22%) and performance validity testing had a notable affect on cognitive test scores. Performance and symptom validity test failure rates did not vary as a function of the reason for disability evaluation when divided into behavioral versus physical health conditions. These data are consistent with past studies, and extends those studies by including symptom validity testing and investigating the effect of reason for MEB. This and previous studies demonstrate that more than 50% of SMs seen in the context of an MEB will fail performance validity tests and over-report on symptom validity measures. These results emphasize the importance of using both performance and symptom validity testing when evaluating SMs with a history of mTBI, especially if they are being seen for disability evaluations, in order to ensure the accuracy of cognitive and psychological test data. Published by Oxford University Press 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Project W-314 specific test and evaluation plan for AZ tank farm upgrades
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hays, W.H.
1998-08-12
The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made by the addition of the SN-631 transfer line from the AZ-O1A pit to the AZ-02A pit by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation P1 an (TEP). Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities, etc), Factory Tests and Inspections (FTIs), installation tests andmore » inspections, Construction Tests and Inspections (CTIs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), and Operational Test Procedures (OTPs). The STEP will be utilized in conjunction with the TEP for verification and validation.« less
[The MMPI-2 test in the evaluation of the mobbing syndrome].
Pappone, P; Santalucia, L; Del Castello, E; De Maino, V; Garofalo, E; Cappelluccio, R; Feola, D; Ruberto, M; Liotti, F
2007-01-01
MMPI-2 test is widely used in psychodiagnostic evaluation as well as in the evaluation of psychic pathologies related to psychosocial adversative events in working activities. A more efficacious use of MMPI-2 test in the working context can be achieved by the individuation of indexes able to facilitate the evaluation of mobbing syndrome. This work is based on the analysis of 150 cases (39.7% women and 60.7% men, 30 to 60 years of age), evaluated through an accurate examination of working history and a series of clinic conversations, followed by psychodiagnostic evaluation. The average of T-scores on the clinical scale, the content scale, the PK addition scale and the validation scale were calculated from tests. Pathologic high T-scores on the scales Hs, D. Hy e Pa were found in subjects having positive mobbing anamnesis. These results strongly indicate the presence of clinical specificities in workers exposed to working harassments, and that these specificities can be efficaciously evidenced by the MMPI-2 test.
Thames, April D; Panos, Stella E; Arentoft, Alyssa; Byrd, Desiree A; Hinkin, Charles H; Arbid, Natalie
2015-01-01
The current study examined ethnic/racial differences in test-related anxiety and its relationship to neurocognitive performance in a community sample of African American (n = 40) and European American (n = 36) adults. The authors hypothesized the following: (a) Test-anxiety related to negative performance evaluation would be associated with lower neurocognitive performance, whereas anxiety unrelated to negative evaluation would be associated with higher neurocognitive performance. (b) African American participants would report higher levels of anxiety about negative performance evaluation than European Americans. (c) European Americans would report higher levels of anxiety unrelated to negative performance evaluation. The first two hypotheses were supported: Ethnic/racial differences in test-taking anxiety emerged such that African Americans reported significantly higher levels of negative performance evaluation, which was associated with lower cognitive performance. The third hypothesis was not supported: African Americans and European Americans reported similar levels of test-anxiety unrelated to negative evaluation. (PsycINFO Database Record (c) 2015 APA, all rights reserved).
Test Methodology to Evaluate the Safety of Materials Using Spark Incendivity
NASA Technical Reports Server (NTRS)
Buhler, Charles; Calle, Carlos; Clements, Sid; Ritz, Mindy; Starnes, Jeff
2007-01-01
For many years scientists and engineers have been searching for the proper test method to evaluate an electrostatic risk for materials used in hazardous environments. A new test standard created by the International Electrotechnical Commission is a promising addition to conventional test methods used throughout industry. The purpose of this paper is to incorporate this test into a proposed new methodology for the evaluation of materials exposed to flammable environments. However, initial testing using this new standard has uncovered some unconventional behavior in materials that conventional test methods were thought to have reconciled. For example some materials tested at higher humidities were more susceptible to incendive discharges than at lower humidity even though the surface resistivity was lower.
Vasconcellos, Luiz Felipe; Pereira, João Santos; Adachi, Marcelo; Greca, Denise; Cruz, Manuela; Malak, Ana Lara; Charchat-Fichman, Helenice; Spitz, Mariana
2017-01-01
Few studies have evaluated magnetic resonance imaging (MRI) visual scales in Parkinson's disease-Mild Cognitive Impairment (PD-MCI). We selected 79 PD patients and 92 controls (CO) to perform neurologic and neuropsychological evaluation. Brain MRI was performed to evaluate the following scales: Global Cortical Atrophy (GCA), Fazekas, and medial temporal atrophy (MTA). The analysis revealed that both PD groups (amnestic and nonamnestic) showed worse performance on several tests when compared to CO. Memory, executive function, and attention impairment were more severe in amnestic PD-MCI group. Overall analysis of frequency of MRI visual scales by MCI subtype did not reveal any statistically significant result. Statistically significant inverse correlation was observed between GCA scale and Mini-Mental Status Examination (MMSE), Montreal Cognitive Assessment (MoCA), semantic verbal fluency, Stroop test, figure memory test, trail making test (TMT) B, and Rey Auditory Verbal Learning Test (RAVLT). The MTA scale correlated with Stroop test and Fazekas scale with figure memory test, digit span, and Stroop test according to the subgroup evaluated. Visual scales by MRI in MCI should be evaluated by cognitive domain and might be more useful in more severely impaired MCI or dementia patients.
Stress Optical Coefficient, Test Methodology, and Glass Standard Evaluation
2016-05-01
identifying and mapping flaw size distributions on glass surfaces for predicting mechanical response. International Journal of Applied Glass ...ARL-TN-0756 ● MAY 2016 US Army Research Laboratory Stress Optical Coefficient, Test Methodology, and Glass Standard Evaluation...Stress Optical Coefficient, Test Methodology, and Glass Standard Evaluation by Clayton M Weiss Oak Ridge Institute for Science and Education
ERIC Educational Resources Information Center
Colorado State Dept. of Education, Denver.
The purpose of the Colorado Evaluation Project was to field test the Common Status Measures at grades four and eleven in conjunction with a statewide assessment program based on objective-referenced testing instruments developed by the Colorado Department of Education for grades kindergarten, three, six, nine, and twelve. The evaluation was…
Organizational Analysis of the United States Army Evaluation Center
2014-12-01
analysis of qualitative or quantitative data obtained from design reviews, hardware inspections, M&S, hardware and software testing , metrics review... Research Development Test & Evaluation (RDT&E) appropriation account. The Defense Acquisition Portal ACQuipedia website describes RDT&E as “ one of the... research , design , development, test and evaluation, production, installation, operation, and maintenance; data collection; processing and analysis
Evaluation Parameters for Computer-Adaptive Testing
ERIC Educational Resources Information Center
Georgiadou, Elisabeth; Triantafillou, Evangelos; Economides, Anastasios A.
2006-01-01
With the proliferation of computers in test delivery today, adaptive testing has become quite popular, especially when examinees must be classified into two categories (passfail, master nonmaster). Several well-established organisations have provided standards and guidelines for the design and evaluation of educational and psychological testing.…
Nonproliferation Test and Evaluation Complex - NPTEC
None
2018-01-16
The Nonproliferation Test and Evaluation Complex, or NPTEC, is the world's largest facility for open air testing of hazardous toxic materials and biological simulants. NPTEC is used for testing, experimentation, and training for technologies that require the release of toxic chemicals or biological simulants into the environment.
Predicting moisture-induced damage to asphaltic concrete : field evaluation : final report.
DOT National Transportation Integrated Search
1981-01-01
Virginia was one of seven agencies that participated in the evaluation of a stripping test developed under National Cooperative Highway Research Program Project 4-8(3). The test was used to predict stripping of a field test section and the test resul...
A test manager's perspective of a test concept for a heavy lift vehicle
NASA Technical Reports Server (NTRS)
Pargeon, John I., Jr.
1990-01-01
The developmment of a test concept is a significant part of the advanced planning activities accomplished for the Initial Operational Test and Evaluation (IOT&E) of new systems. A test concept is generally viewed as a description, including rationale, of the test structure, evaluation methodology and management approach required to plan and conduct the IOT&E of a program such as a new heavy lift launch vehicle system. The test concept as presented in this paper is made up of an operations area, a test area, an evaluation area, and a management area. The description presented here is written from the perspective of one test manager, and represents his views of a possible framework of a test concept using examples for a potential IOT&E of a heavy lift launch vehicle.
The effects of non-evaluative feedback on drivers' self-evaluation and performance.
Dogan, Ebru; Steg, Linda; Delhomme, Patricia; Rothengatter, Talib
2012-03-01
Drivers' tend to overestimate their competences, which may result in risk taking behavior. Providing drivers with feedback has been suggested as one of the solutions to overcome drivers' inaccurate self-evaluations. In practice, many tests and driving simulators provide drivers with non-evaluative feedback, which conveys information on the level of performance but not on what caused the performance. Is this type of feedback indeed effective in reducing self-enhancement biases? The current study aimed to investigate the effect of non-evaluative performance feedback on drivers' self-evaluations using a computerized hazard perception test. A between-subjects design was used with one group receiving feedback on performance in the hazard perception test while the other group not receiving any feedback. The results indicated that drivers had a robust self-enhancement bias in their self-evaluations regardless of the presence of performance feedback and that they systematically estimated their performance to be higher than they actually achieved in the test. Furthermore, they devalued the credibility of the test instead of adjusting their self-evaluations in order to cope with the negative feelings following the failure feedback. We discuss the theoretical and practical implications of these counterproductive effects of non-evaluative feedback. Copyright © 2011 Elsevier Ltd. All rights reserved.
2013-09-01
ER D C/ G SL T R -1 3 -2 4 Evaluation of Precast Panels for Airfield Pavement Repair Phase II: Results of Accelerated Pavement Testing...default. ERDC/GSL TR-13-24 September 2013 Evaluation of Precast Panels for Airfield Pavement Repair Phase II: Results of Accelerated Pavement ... pavement testing using a C-17 load cart to evaluate the performance of a precast portland cement concrete (PCC) pavement repair system. The system
ASTM test methods for composite characterization and evaluation
NASA Technical Reports Server (NTRS)
Masters, John E.
1994-01-01
A discussion of the American Society for Testing and Materials is given. Under the topic of composite materials characterization and evaluation, general industry practice and test methods for textile composites are presented.
NASA Technical Reports Server (NTRS)
Saulsberry, Regor; Greene, Nathanael; Cameron, Ken; Madaras, Eric; Grimes-Ledesma, Lorie; Thesken, John; Phoenix, Leigh; Murthy, Pappu; Revilock, Duane
2007-01-01
Many aging composite overwrapped pressure vessels (COPVs), being used by the National Aeronautics and Space Administration (NASA) are currently under evaluation to better quantify their reliability and clarify their likelihood of failure due to stress rupture and age-dependent issues. As a result, some test and analysis programs have been successfully accomplished and other related programs are still in progress at the NASA Johnson Space Center (JSC) White Sands Test Facility (WSTF) and other NASA centers, with assistance from the commercial sector. To support this effort, a group of Nondestructive Evaluation (NDE) experts was assembled to provide NDE competence for pretest evaluation of test articles and for application of NDE technology to real-time testing. Techniques were required to provide assurance that the test article had adequate structural integrity and manufacturing consistency to be considered acceptable for testing and these techniques were successfully applied. Destructive testing is also being accomplished to better understand the physical and chemical property changes associated with progression toward "stress rupture" (SR) failure, and it is being associated with NDE response, so it can potentially be used to help with life prediction. Destructive work also includes the evaluation of residual stresses during dissection of the overwrap, laboratory evaluation of specimens extracted from the overwrap to evaluate physical property changes, and quantitative microscopy to inform the theoretical micromechanics.
Kaplan, M F
1975-07-01
Trait adjectives commonly employed in person perception studies have both evaluative and denotative meanings. Evaluative ratings of single traits shift with variations in the context of other traits ascribed to the stimulus person; the extent to which denotative changes underlie these evaluative context effects has been a theoretical controversy. In the first experiment, it was shown that context effects on quantitative ratings of denotation can be largely accounted for by evaluative halo effects. In the second experiment, increasing the denotative relatedness of context traits to the test trait didnot increase the effect of the context. Only the evaluative meaning of the context affected evaluation of the rated test trait. These studies suggest that the denotative relationship between a test adjective and its context has little influence on context effects in person perception, and that denotative meaning changes do not mediate context effects. Instead, evaluative judgments appear to be based on evaluative meaning.
Reaction propagation test. Evaluation of the behavior of nonmetallic materials in hydrogen
NASA Technical Reports Server (NTRS)
Smith, I. D.
1972-01-01
Results of tests conducted to evaluate the behavior of nonmetallic materials in hydrogen are described. The reaction propagation test simulates the conditions resulting from the interaction of an electrical wire in an overload condition in contract with a material in the test medium. The test is designed to evaluate the behavior of a material subjected to an energy input (usually heat) sufficient to cause a reaction which propagates to consume larger quantities of the material. Ten nonmetallic materials were evaluated to establish baseline data on the behavior of nonmetallic materials in hydrogen and to characterize, on an initial basis, one mode of material failure considered to be a factor pertinent to the safe use of a material in hydrogen.
Technical Evaluation Motor No. 7 (TEM-7)
NASA Technical Reports Server (NTRS)
Hughes, Phil
1991-01-01
The Technical Evaluation Motor No. 7 (TEM-7) test was a full-scale, full duration static test firing of a high performance motor-configuration solid rocket motor with nozzle vectoring. The final test report documents the procedures, performance, and results of the static test firing of TEM-7. All observations, discussions, conclusions, and recommendations included in the report are complete and final except for the TEM-7 fixed housing unbond investigation. A presentation and discussion of TEM-7 performance, anomalies, and test result concurrence with the objectives outlined in CTP-0107, Rev A, Space Shuttle Technical Evaluation Motor No. 7 (TEM-7) Static Fire Test Plan are included.
Hybrid Bearing Prognostic Test Rig
NASA Technical Reports Server (NTRS)
Dempsey, Paula J.; Certo, Joseph M.; Handschuh, Robert F.; Dimofte, Florin
2005-01-01
The NASA Glenn Research Center has developed a new Hybrid Bearing Prognostic Test Rig to evaluate the performance of sensors and algorithms in predicting failures of rolling element bearings for aeronautics and space applications. The failure progression of both conventional and hybrid (ceramic rolling elements, metal races) bearings can be tested from fault initiation to total failure. The effects of different lubricants on bearing life can also be evaluated. Test conditions monitored and recorded during the test include load, oil temperature, vibration, and oil debris. New diagnostic research instrumentation will also be evaluated for hybrid bearing damage detection. This paper summarizes the capabilities of this new test rig.
Villasís-Keever, Miguel Ángel; Rizzoli-Córdoba, Antonio; Delgado-Ginebra, Ismael; Mares-Serratos, Blanca Berenice; Martell-Valdez, Liliana; Sánchez-Velázquez, Olivia; Reyes-Morales, Hortensia; O'Shea-Cuevas, Gabriel; Aceves-Villagrán, Daniel; Carrasco-Mendoza, Joaquín; Antillón-Ocampo, Fátima Adriana; Villagrán-Muñoz, Víctor Manuel; Halley-Castillo, Elizabeth; Baqueiro-Hernández, César Iván; Pizarro-Castellanos, Mariel; Martain-Pérez, Itzamara Jacqueline; Palma-Tavera, Josuha Alexander; Vargas-López, Guillermo; Muñoz-Hernández, Onofre
The Child Development Evaluation (CDE) test designed and validated in Mexico has been used as a screening tool for developmental problems in primary care facilities across Mexico. Heterogeneous results were found among those states where these were applied, despite using the same standardized training model for application. The objective was to evaluate a supervision model for quality of application of the CDE test at primary care facilities. A study was carried out in primary care facilities from three Mexican states to evaluate concordance of the results between supervisor and primary care personnel who administered the test using two different methods: direct observation (shadow study) or reapplication of the CDE test (consistency study). There were 380 shadow studies applied to 51 psychologists. General concordance of the shadow study was 86.1% according to the supervisor: green 94.5%, yellow 73.2% and red 80.0%. There were 302 re-test evaluations with a concordance of 88.1% (n=266): green 96.8%, yellow 71.7% and red 81.8%. There were no differences between CDE test subgroups by age. Both shadow and re-test study were adequate for the evaluation of the quality of the administration of the CDE Test and may be useful as a model of supervision in primary care facilities. The decision of which test to use relies on the availability of supervisors. Copyright © 2015 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.
DOT National Transportation Integrated Search
2002-08-01
The purpose of this research was to evaluate the effectiveness of soil cement shrinkage crack mitigation techniques. The contents of this report reflect an evaluation of the construction of the test sections and a two-year evaluation of the test sect...
Review of test methods used to determine the corrosion rate of metals in contact with treated wood
Samuel L. Zelinka; Douglas R. Rammer
2005-01-01
The purpose of this literature review is to give an overview of test methods previously used to evaluate the corrosion of metals in contact with wood. This article reviews the test methods used to evaluate the corrosion of metals in contact with wood by breaking the experiments into three groups: exposure tests, accelerated exposure tests, and electrochemical tests....
An Evaluation of Test Speededness in an Assessment for Third-Grade Gifted Students
ERIC Educational Resources Information Center
Hailey, Emily; Callahan, Carolyn M.; Azano, Amy; Moon, Tonya R.
2012-01-01
Reliability and validity are integral concepts in assessment design. Test speededness, the influence of time constraints on test taker performance, is often an overlooked threat to reliability and validity, especially in classroom-based testing. The purpose of this study is to evaluate the degree of test speededness of classroom-based assessments…
76 FR 27016 - Evaluating Test Procedures for Voting Systems
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-10
...-02] Evaluating Test Procedures for Voting Systems AGENCY: National Institute of Standards and... Assistance Commission for use by NIST in research to develop and assess NIST's test procedures for voting... develop and assess NIST test protocols for voting equipment. NIST research is designed to: (1) Develop...
Thermal Response of UHMWPE Materials in a Flash Flame Test Environment
2014-11-13
Evaluation of Flame Resistant Clothing for Protection Against Fire Simulations Using an Instrumented Manikin. Several UHMWPE fabrics were tested underneath...PROTECTIVE CLOTHING COTTON FLASH FLAMES UNDERGARMENTS TEST AND EVALUATION FABRICS FLAME TESTING FIRE ...PROTECTION FIRE RESISTANT TEXTILES UHMWPE(ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE
[Research progress on mechanical performance evaluation of artificial intervertebral disc].
Li, Rui; Wang, Song; Liao, Zhenhua; Liu, Weiqiang
2018-03-01
The mechanical properties of artificial intervertebral disc (AID) are related to long-term reliability of prosthesis. There are three testing methods involved in the mechanical performance evaluation of AID based on different tools: the testing method using mechanical simulator, in vitro specimen testing method and finite element analysis method. In this study, the testing standard, testing equipment and materials of AID were firstly introduced. Then, the present status of AID static mechanical properties test (static axial compression, static axial compression-shear), dynamic mechanical properties test (dynamic axial compression, dynamic axial compression-shear), creep and stress relaxation test, device pushout test, core pushout test, subsidence test, etc. were focused on. The experimental techniques using in vitro specimen testing method and testing results of available artificial discs were summarized. The experimental methods and research status of finite element analysis were also summarized. Finally, the research trends of AID mechanical performance evaluation were forecasted. The simulator, load, dynamic cycle, motion mode, specimen and test standard would be important research fields in the future.
Evaluation of Mysidopsis bahia fecundity endpoint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Griffin, D.; Wahl, E.; Krause, P.R.
1995-12-31
The M. bahia chronic toxicity test is commonly used to test estuarine and marine effluent discharges. The test evaluates three endpoints: survival, growth, and fecundity. The fecundity endpoint is often erratic over time and does not necessarily predict accurately other endpoints of effluent toxicity. Therefore, an analysis of the fecundity endpoint was performed to evaluate its use in compliance testing. The endpoint analysis was conducted in three phases: a literature search, analysis of M. bahia data from 24 separate testing events, and interviews with various policy makers, statisticians, and biologists. The literature search revealed a dozen publications, none of whichmore » evaluated fecundity using the EPA method. The literature suggested that evaluating fecundity was labor-intensive and inadequate for practical compliance testing applications. Analysis of the 24 tests revealed that fecundity was evaluated only half of the time (i.e. when at least 50% of the females in the control were fecund). There was a high coefficient of variation (C.V.) between replicates for fecundity (range = 9.--1209.3,x = 85.2%) as compared to survival (range = 0.0--24.0,x = 13.7 %) and growth (range = 7.5--43.9,x = 19.1%). The fecundity results were erratic and did not always follow a dose-response curve, due in part to the small sample size per replicate. Interviews showed that the fecundity endpoint was being evaluated differently by different laboratories. Some were using fecundity for compliance while others were not. Most people interviewed recognized there were inconsistencies with the endpoint. The conclusions drawn from the evaluation were that (1) fecundity does not lend itself for use as a compliance endpoint, (2) the fecundity evaluation process is time consuming and labor intensive, and (3) interpretation of the results is not consistent from laboratory to laboratory and from region to region.« less
Fujita, Yurika; Kasamatsu, Toshio; Ikeda, Naohiro; Nishiyama, Naohiro; Honda, Hiroshi
2016-01-15
Although in vitro chromosomal aberration tests and micronucleus tests have been widely used for genotoxicity evaluation, false-positive results have been reported under strong cytotoxic conditions. To reduce false-positive results, the new Organization for Economic Co-operation and Development (OECD) test guideline (TG) recommends the use of a new cytotoxicity index, relative increase in cell count or relative population doubling (RICC/RPD), instead of the traditionally used index, relative cell count (RCC). Although the use of the RICC/RPD may result in different outcomes and require re-evaluation of tested substances, it is impractical to re-evaluate all existing data. Therefore, we established a method to estimate test results from existing RCC data. First, we developed formulae to estimate RICC/RPD from RCC without cell counts by considering cell doubling time and experiment time. Next, the accuracy of the cytotoxicity index transformation formulae was verified by comparing estimated RICC/RPD and measured RICC/RPD for 3 major chemicals associated with false-positive genotoxicity test results: ethyl acrylate, eugenol and p-nitrophenol. Moreover, 25 compounds with false-positive in vitro chromosomal aberration (CA) test results were re-evaluated to establish a retrospective evaluation method based on derived estimated RICC/RPD values. The estimated RICC/RPD values were in good agreement with the measured RICC/RPD values for every concentration and chemical, and the estimated RICC suggested the possibility that 12 chemicals (48%) with previously judged false-positive results in fact had negative results. Our method enables transformation of RCC data into RICC/RPD values with a high degree of accuracy and will facilitate comprehensive retrospective evaluation of test results. Copyright © 2015 Elsevier B.V. All rights reserved.
Engel, M F; van Manen, L; Hoepelman, A I M; Thijsen, S; Oosterheert, J J
2013-09-01
A positive urinary antigen test for Legionella spp. (Legionella urinary antigen test; LUAT) allows an early switch from empiric to targeted treatment (TT) in hospitalised, community-acquired pneumonia (CAP) patients. We aimed to evaluate the diagnostic, therapeutic and economic consequences of this frequently used test 7 years after its implementation. We retrospectively evaluated LUATs performed between 2005 and 2011 in two teaching hospitals. All tests performed in hospitalised CAP patients were used in the economic evaluation and positive tests were included in the treatment evaluation. Data on patient characteristics, admission and outcome were retrieved from the patients' files. The number of days gained by making a rapid aetiological diagnosis, the number of days TT could be provided and their costs were calculated. Of 4485 LUATs, 2504 (56%) were performed for CAP including 55 (1%) positive tests (€1041/positive test). In 26 (60%) of the 43 included positive tests, LUAT was the only test showing Legionella spp. Subsequently, earlier TT was possible in the remaining cases during 209 cumulative admission days (€274/TT day). LUAT led to detection of Legionella spp. 13 days earlier per case (€203/day) as compared with culture/serology alone. Timely LUAT use in accordance with current guidelines allows early detection and treatment of CAP caused by Legionella spp. at considerable expense.
[Continuing medical education: how to write multiple choice questions].
Soler Fernández, R; Méndez Díaz, C; Rodríguez García, E
2013-06-01
Evaluating professional competence in medicine is a difficult but indispensable task because it makes it possible to evaluate, at different times and from different perspectives, the extent to which the knowledge, skills, and values required for exercising the profession have been acquired. Tests based on multiple choice questions have been and continue to be among the most useful tools for objectively evaluating learning in medicine. When these tests are well designed and correctly used, they can stimulate learning and even measure higher cognitive skills. Designing a multiple choice test is a difficult task that requires knowledge of the material to be tested and of the methodology of test preparation as well as time to prepare the test. The aim of this article is to review what can be evaluated through multiple choice tests, the rules and guidelines that should be taken into account when writing multiple choice questions, the different formats that can be used, the most common errors in elaborating multiple choice tests, and how to analyze the results of the test to verify its quality. Copyright © 2012 SERAM. Published by Elsevier Espana. All rights reserved.
Effects of handcuffs on neuropsychological testing: Implications for criminal forensic evaluations.
Biddle, Christine M; Fazio, Rachel L; Dyshniku, Fiona; Denney, Robert L
2018-01-01
Neuropsychological evaluations are increasingly performed in forensic contexts, including in criminal settings where security sometimes cannot be compromised to facilitate evaluation according to standardized procedures. Interpretation of nonstandardized assessment results poses significant challenges for the neuropsychologist. Research is limited in regard to the validation of neuropsychological test accommodation and modification practices that deviate from standard test administration; there is no published research regarding the effects of hand restraints upon neuropsychological evaluation results. This study provides preliminary results regarding the impact of restraints on motor functioning and common neuropsychological tests with a motor component. When restrained, performance on nearly all tests utilized was significantly impacted, including Trail Making Test A/B, a coding test, and several tests of motor functioning. Significant performance decline was observed in both raw scores and normative scores. Regression models are also provided in order to help forensic neuropsychologists adjust for the effect of hand restraints on raw scores of these tests, as the hand restraints also resulted in significant differences in normative scores; in the most striking case there was nearly a full standard deviation of discrepancy.
NASA Astrophysics Data System (ADS)
Strader, Anne; Schorlemmer, Danijel; Beutin, Thomas
2017-04-01
The Global Earthquake Activity Rate Model (GEAR1) is a hybrid seismicity model, constructed from a loglinear combination of smoothed seismicity from the Global Centroid Moment Tensor (CMT) earthquake catalog and geodetic strain rates (Global Strain Rate Map, version 2.1). For the 2005-2012 retrospective evaluation period, GEAR1 outperformed both parent strain rate and smoothed seismicity forecasts. Since 1. October 2015, GEAR1 has been prospectively evaluated by the Collaboratory for the Study of Earthquake Predictability (CSEP) testing center. Here, we present initial one-year test results of the GEAR1, GSRM and GSRM2.1, as well as localized evaluation of GEAR1 performance. The models were evaluated on the consistency in number (N-test), spatial (S-test) and magnitude (M-test) distribution of forecasted and observed earthquakes, as well as overall data consistency (CL-, L-tests). Performance at target earthquake locations was compared between models using the classical paired T-test and its non-parametric equivalent, the W-test, to determine if one model could be rejected in favor of another at the 0.05 significance level. For the evaluation period from 1. October 2015 to 1. October 2016, the GEAR1, GSRM and GSRM2.1 forecasts pass all CSEP likelihood tests. Comparative test results show statistically significant improvement of GEAR1 performance over both strain rate-based forecasts, both of which can be rejected in favor of GEAR1. Using point process residual analysis, we investigate the spatial distribution of differences in GEAR1, GSRM and GSRM2 model performance, to identify regions where the GEAR1 model should be adjusted, that could not be inferred from CSEP test results. Furthermore, we investigate whether the optimal combination of smoothed seismicity and strain rates remains stable over space and time.
Electric Vehicle and Wireless Charging Laboratory
DOT National Transportation Integrated Search
2018-03-23
Wireless charging tests of electric vehicles (EV) have been conducted at the EVTC Wireless Laboratory located at the Florida Solar Energy Center, Cocoa, FL. These tests were performed to document testing protocols, evaluate standards and evaluate ope...
Christian, Susan; Atallah, Joseph; Clegg, Robin; Giuffre, Michael; Huculak, Cathleen; Dzwiniel, Tara; Parboosingh, Jillian; Taylor, Sherryl; Somerville, Martin
2018-02-01
Predictive genetic testing in minors should be considered when clinical intervention is available. Children who carry a pathogenic variant for an inherited arrhythmia or cardiomyopathy require regular cardiac screening and may be prescribed medication and/or be told to modify their physical activity. Medical genetics and pediatric cardiology charts were reviewed to identify factors associated with uptake of genetic testing and cardiac evaluation for children at risk for long QT syndrome, hypertrophic cardiomyopathy or arrhythmogenic right ventricular cardiomyopathy. The data collected included genetic diagnosis, clinical symptoms in the carrier parent, number of children under 18 years of age, age of children, family history of sudden cardiac arrest/death, uptake of cardiac evaluation and if evaluated, phenotype for each child. We identified 97 at risk children from 58 families found to carry a pathogenic variant for one of these conditions. Sixty six percent of the families pursued genetic testing and 73% underwent cardiac screening when it was recommended. Declining predictive genetic testing was significantly associated with genetic specialist recommendation (p < 0.001) and having an asymptomatic carrier father (p = 0.006). Cardiac evaluation was significantly associated with uptake of genetic testing (p = 0.007). This study provides a greater understanding of factors associated with uptake of genetic testing and cardiac evaluation in children at risk of an inherited arrhythmia or cardiomyopathy. It also identifies a need to educate families about the importance of cardiac evaluation even in the absence of genetic testing.
Proceedings: 19th International Nondestructive Testing and Evaluation of Wood Symposium
Robert J. Ross; Raquel Gonçalves; Xiping Wang
2015-01-01
The 19th International Nondestructive Testing and Evaluation of Wood Symposium was hosted by the University of Campinas, College of Agricultural Engineering (FEAGRI/UNICAMP), and the Brazilian Association of Nondestructive Testing and Evaluation (ABENDI) in Rio de Janeiro, Brazil, on September 22â25, 2015. This Symposium was a forum for those involved in nondestructive...
TACCDAS Testbed Human Factors Evaluation Methodology,
1980-03-01
3 TEST METHOD Development of performance criteria................... 8 Test participant identification ...................... 8 Control of...major milestones involved in the evaluation process leading up to the evaluation of the complete testbed in the field are identified. Test methods and...inevitably will be different in several ways from the intended system as foreseen by the system designers. The system users provide insights into these
Evaluation of scanning earth sensor mechanism on engineering test satellite 4
NASA Technical Reports Server (NTRS)
Ikeuchi, M.; Wakabayashi, Y.; Ohkami, Y.; Kida, T.; Ishigaki, T.; Matsumoto, M.
1983-01-01
The results of the analysis and the evaluation of flight data obtained from the horizon sensor test project are described. The rotary mechanism of the scanning earth sensor composed of direct drive motor and bearings using solid lubricant is operated satisfactorily. The transmitted flight data from Engineering Test Satellite IV was evaluated in comparison with the design value.
2015-03-26
TEST AND EVALUATION OF ULTRASONIC ADDITIVE MANUFACTURING (UAM) FOR A LARGE AREA MAINTENANCE...States Government. AFIT-ENV-MS-15-M-158 TEST AND EVALUATION OF ULTRASONIC ADDITIVE MANUFACTURING FOR A LARGE AREA MAINTENANCE SHELTER...Civil Engineer (CE) operations. This research replicates a Large Area Maintenance Shelter (LAMS) baseplate design for ultrasonic additive
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1980-01-01
Evaluation tests of 10 nickel cadmium cells are described. Although pressures were greater than what normally was exhibited by General Electric cells in the past, it is recommended that these cells be placed on life test simulating the predicted Dynamic Explorer flight profiles.
R&D Priorities for Educational Testing and Evaluation: The Testimony of the CRESST National Faculty.
ERIC Educational Resources Information Center
Herman, Joan L., Ed.
At the 1989 meeting of the National Faculty of the Center for Research on Evaluation, Standards, and Student Testing (CRESST), faculty members were invited to present testimony on what they viewed as the most pressing research and policy issues in the fields of testing, evaluation, and standards. These views are expressed in this document,…
DOT National Transportation Integrated Search
2003-10-02
This document is one of a series of working papers that report on progress for the US DOT evaluation for Phase I of the ORANGES field operational test. Each working paper corresponds to a Phase I task. At the conclusion of Phase I, these documents wi...
When the third party observer of a neuropsychological evaluation is an audio-recorder.
Constantinou, Marios; Ashendorf, Lee; McCaffrey, Robert J
2002-08-01
The presence of third parties during neuropsychological evaluations is an issue of concern for contemporary neuropsychologists. Previous studies have reported that the presence of an observer during neuropsychological testing alters the performance of individuals under evaluation. The present study sought to investigate whether audio-recording affects the neuropsychological test performance of individuals in the same way that third party observation does. In the presence of an audio-recorder the performance of the participants on memory tests declined. Performance on motor tests, on the other hand, was not affected by the presence of an audio-recorder. The implications of these findings in forensic neuropsychological evaluations are discussed.
Evaluation of a metering, mixing, and dispensing system for mixing polysulfide adhesive
NASA Technical Reports Server (NTRS)
Evans, Kurt B.
1989-01-01
Tests were performed to evaluate whether a metered mixing system can mix PR-1221 polysulfide adhesive as well as or better than batch-mixed adhesive; also, to evaluate the quality of meter-mixed PR-1860 and PS-875 polysulfide adhesives. These adhesives are candidate replacements for PR-1221 which will not be manufactured in the future. The following material properties were evaluated: peel strength, specific gravity and adhesive components of mixed adhesives, Shore A hardness, tensile adhesion strength, and flow rate. Finally, a visual test called the butterfly test was performed to observe for bubbles and unmixed adhesive. The results of these tests are reported and discussed.
DOT National Transportation Integrated Search
2004-12-06
This report describes the findings of the US DOT-sponsored evaluation of the Orlando (Florida) ORANGES multi-modal Field Operational Test (FOT); the report includes: a background description of the ORANGES FOT; the Evaluation Strategy and Plan, which...
Testing and Evaluation of the EOSDIS Core System: An ECS Science Advisor Proposal
NASA Technical Reports Server (NTRS)
Welch, Ronald M.; Christopher, Sundar A.
1997-01-01
The major goal of this project was to: 1) perform hands on testing of the evaluation packages, 2) provide feedback in the design of the EOSDIS Core System, and 3) test the effectiveness of the DAAC's by acquiring and testing remote sensing data sets.
Test and Evaluation of an Eddy Current Clutch/Brake Propulsion System
DOT National Transportation Integrated Search
1975-01-01
This report covers the Phase II effort of a program to develop and test a 15 hp eddy-current clutch propulsion system. Included in the Phase 2 effort are the test and evaluation of the eddy-current clutch propulsion system on board a test vehicle. Th...
Non-destructive evaluation techniques, high temperature ceramic component parts for gas turbines
NASA Technical Reports Server (NTRS)
Reiter, H.; Hirsekorn, S.; Lottermoser, J.; Goebbels, K.
1984-01-01
This report concerns studies conducted on various tests undertaken on material without destroying the material. Tests included: microradiographic techniques, vibration analysis, high-frequency ultrasonic tests with the addition of evaluation of defects and structure through analysis of ultrasonic scattering data, microwave tests and analysis of sound emission.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-10
... validation studies. NICEATM and ICCVAM work collaboratively to evaluate new and improved test methods... for nomination of test methods for validation studies, and guidelines for submission of test methods... for human and veterinary vaccine post-licensing potency and safety testing. Plenary and breakout...
Test and evaluation of the Navy half-watt RTG. [Radioisotope Thermoelectric Generator
NASA Technical Reports Server (NTRS)
Rosell, F. E., Jr.; Lane, S. D.; Eggers, P. E.; Gawthrop, W. E.; Rouklove, P. G.; Truscello, V. C.
1976-01-01
The radioisotope thermoelectric generator (RTG) considered is to provide a continuous minimum power output of 0.5 watt at 6.0 to 8.5 volts for a minimum period of 15 years. The mechanical-electrical evaluation phase discussed involved the conduction of shock and vibration tests. The thermochemical-physical evaluation phase consisted of an analysis of the materials and the development of a thermal model. The thermoelectric evaluation phase included the accelerated testing of the thermoelectric modules.
Integrated System Test Approaches for the NASA Ares I Crew Launch Vehicle
NASA Technical Reports Server (NTRS)
Cockrell, Charles
2008-01-01
NASA is maturing test and evaluation plans leading to flight readiness of the Ares I crew launch vehicle. Key development, qualification, and verification tests are planned . Upper stage engine sea-level and altitude testing. First stage development and qualification motors. Upper stage structural and thermal development and qualification test articles. Main Propulsion Test Article (MPTA). Upper stage green run testing. Integrated Vehicle Ground Vibration Testing (IVGVT). Aerodynamic characterization testing. Test and evaluation supports initial validation flights (Ares I-Y and Orion 1) and design certification.
NASA Technical Reports Server (NTRS)
Putnam, Jacob P.; Untaroiu, Costin; Somers. Jeffrey
2014-01-01
In an effort to develop occupant protection standards for future multipurpose crew vehicles, the National Aeronautics and Space Administration (NASA) has looked to evaluate the test device for human occupant restraint with the modification kit (THOR-K) anthropomorphic test device (ATD) in relevant impact test scenarios. With the allowance and support of the National Highway Traffic Safety Administration, NASA has performed a series of sled impact tests on the latest developed THOR-K ATD. These tests were performed to match test conditions from human volunteer data previously collected by the U.S. Air Force. The objective of this study was to evaluate the THOR-K finite element (FE) model and the Total HUman Model for Safety (THUMS) FE model with respect to the tests performed. These models were evaluated in spinal and frontal impacts against kinematic and kinetic data recorded in ATD and human testing. Methods: The FE simulations were developed based on recorded pretest ATD/human position and sled acceleration pulses measured during testing. Predicted responses by both human and ATD models were compared to test data recorded under the same impact conditions. The kinematic responses of the models were quantitatively evaluated using the ISO-metric curve rating system. In addition, ATD injury criteria and human stress/strain data were calculated to evaluate the risk of injury predicted by the ATD and human model, respectively. Results: Preliminary results show well-correlated response between both FE models and their physical counterparts. In addition, predicted ATD injury criteria and human model stress/strain values are shown to positively relate. Kinematic comparison between human and ATD models indicates promising biofidelic response, although a slightly stiffer response is observed within the ATD. Conclusion: As a compliment to ATD testing, numerical simulation provides efficient means to assess vehicle safety throughout the design process and further improve the design of physical ATDs. The assessment of the THOR-K and THUMS FE models in a spaceflight testing condition is an essential first step to implementing these models in the computational evaluation of spacecraft occupant safety. Promising results suggest future use of these models in the aerospace field.
Evaluation of a Schatz heat battery on a flexible-fueled vehicle
NASA Astrophysics Data System (ADS)
Piotrowski, Gregory K.; Schaefer, Ronald M.
1991-09-01
The evaluation is described of a Schatz Heat Battery as a means of reducing cold start emissions from a motor vehicle fueled with both gasoline and M85 high methanol blend fuel. The evaluation was conducted at both 20 and 75 F ambient temperatures. The test vehicle was a flexible fueled 1990 Audi 80 supplied by Volkswagen of America. A description is included of the test vehicle, the test facilities, the analytical methods and test procedures used.
Evaluation of a Schatz heat battery on a flexible-fueled vehicle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piotrowski, G.K.; Schaefer, R.M.
The report describes the evaluation of a Schatz Heat Battery as a means of reducing cold start emissions from a motor vehicle fueled with both gasoline and M85 high methanol blend fuel. The evaluation was conducted at both 20 F and 75 F ambient temperatures. The test vehicle was a flexible-fueled 1990 Audi 80 supplied by Volkswagen of America. The report also includes a description of the test vehicle, the test facilities, the analytical methods and test procedures used.
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1975-01-01
An evaluation test program was conducted to insure that all cells put into the life cycle program are of high quality by the screening of cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open-circuit voltage above 1.150 volts during the internal short test. Tests and results are described.
A ruggedness evaluation of procedures for damage threshold testing optical materials
NASA Technical Reports Server (NTRS)
Hooker, Matthew W.; Thomas, Milfred E.; Wise, Stephanie A.; Tappan, Nina D.
1995-01-01
A ruggedness evaluation of approaches to damage threshold testing was performed to determine the influence of three procedural variables on damage threshold data. The differences between the number of test sites evaluated at an applied fluence level (1 site versus 10 sites), the number of laser pulses at each test site (1 pulse versus 200 pulses), and the beam diameter (0.35 mm versus 0.70 mm) were all found to significantly influence the damage threshold data over a 99-percent confidence interval.
Evaluation of Dry, Rough Vacuum Pumps
NASA Technical Reports Server (NTRS)
Hunter, Brian
2006-01-01
This document provides information on the testing and evaluation of thirteen dry rough vacuum pumps of various designs and from various manufacturers. Several types of rough vacuum pumps were evaluated, including scroll, roots, and diaphragm pumps. Tests included long term testing, speed curve generation, voltage variance, vibrations emissions and susceptibility, electromagnetic interference emissions and susceptibility, static leak rate, exhaust restriction, response/recovery time tests, and a contamination analysis for scroll pumps. Parameters were found for operation with helium, which often is not provided from the manufacturer
Shuttle payload vibroacoustic test plan evaluation
NASA Technical Reports Server (NTRS)
Stahle, C. V.; Gongloff, H. R.; Young, J. P.; Keegan, W. B.
1977-01-01
Statistical decision theory is used to evaluate seven alternate vibro-acoustic test plans for Space Shuttle payloads; test plans include component, subassembly and payload testing and combinations of component and assembly testing. The optimum test levels and the expected cost are determined for each test plan. By including all of the direct cost associated with each test plan and the probabilistic costs due to ground test and flight failures, the test plans which minimize project cost are determined. The lowest cost approach eliminates component testing and maintains flight vibration reliability by performing subassembly tests at a relatively high acoustic level.
FleetForward evaluation : final report
DOT National Transportation Integrated Search
2000-10-01
This document is the final report for the evaluation of the I-95 Corridor Coalitions FleetForward operational test. The objective of this test was to evaluate the usefulness of traffic flow data to motor carrier operations. Cambridge Systematics, in ...
Acquisition and evaluation of Hamburg wheel-tracking device
DOT National Transportation Integrated Search
1999-04-01
Surrogate performance tests, or "proof" tests, for asphalt mixtures are being evaluated by states to gauge mixture performance potential in the lab. The University of Arkansas constructed, ERSA (Evaluator of Rutting and Stripping in Asphalt) to "scre...
WMATA Rapid Transit Vehicle Engineering Tests
DOT National Transportation Integrated Search
1979-05-01
TSC has been instrumental in preparing standardized test procedures for evaluation of rail transit vehicles, using the TTC's 9.1 mile Transit Test Track, with the objective of providing a common baseline for the comparative evaluation of rapid transi...
Neurobehavioral toxicity testing for risk assessment.
Neurobehavioral evaluations are key components in neurotoxicity testing. In the realm of regulatory testing, these evaluations range from a functional observational battery (FOB) and an Irwin’s screen, which assess the neurological, motor, and functional integrity of the subject...
PCP IMMUMOASSAY TECHNOLOGIES - INNOVATIVE TECHNOLOGY EVALUATION REPORT
Three enzyme-linked immunosorbent assay technologies for pentachlorophenol (PCP) testing in soil and water were evaluated. Penta RISc Test Systems (formerly ENSYS, Inc.), EnviroGard™ PCP Immunoassay Test Kit (Millipore Corp.), and Pentachlorophenol RaPID Assay (formerly Ohmicron ...
The Rene 150 directionally solidified superalloy turbine blades, volume 1
NASA Technical Reports Server (NTRS)
Deboer, G. J.
1981-01-01
Turbine blade design and analysis, preliminary Rene 150 system refinement, coating adaptation and evaluation, final Rene 150 system refinement, component-test blade production and evaluation, engine-test blade production, and engine test are discussed.
Jackson, Jeffrey B
2017-11-01
The following short report outlines a proposed study designed to evaluate the Interprofessional Collaborative Competency Attainment Survey and its recommended method of administration. This exploratory study seeks to determine if there is a significant difference between two methods of administration, the recommended and validated retrospective pre-test and post-test, and a traditional pre-test and post-test. If a significant difference does exist, this data will provide a means to determine the effect size of that difference. The comparison will be done using repeated measure ANOVA and the subsequent effect size will be evaluated using Cohen's d. As the retrospective design is utilised to evaluate a change in perceived competency, comparison of data from a traditional pre-test with a retrospective pre-test may provide a means for evaluation of the participants' change in understanding of the construct, and thus a more thorough picture of the forces driving changes to scores.
ERIC Educational Resources Information Center
Evers, Arne; Sijtsma, Klaas; Lucassen, Wouter; Meijer, Rob R.
2010-01-01
This article describes the 2009 revision of the Dutch Rating System for Test Quality and presents the results of test ratings from almost 30 years. The rating system evaluates the quality of a test on seven criteria: theoretical basis, quality of the testing materials, comprehensiveness of the manual, norms, reliability, construct validity, and…
ERIC Educational Resources Information Center
Hwang, Gwo-Jen; Chu, Hui-Chun; Yin, Peng-Yeng; Lin, Ji-Yu
2008-01-01
The national certification tests and entrance examinations are the most important tests for proving the ability or knowledge level of a person. To accurately evaluate the professional skills or knowledge level, the composed test sheets must meet multiple assessment criteria such as the ratio of relevant concepts to be evaluated and the estimated…
NASA Astrophysics Data System (ADS)
Noble, Clifford Elliott, II
2002-09-01
The problem. The purpose of this study was to investigate the ability of three single-task instruments---(a) the Test of English as a Foreign Language, (b) the Aviation Test of Spoken English, and (c) the Single Manual-Tracking Test---and three dual-task instruments---(a) the Concurrent Manual-Tracking and Communication Test, (b) the Certified Flight Instructor's Test, and (c) the Simulation-Based English Test---to predict the language performance of 10 Chinese student pilots speaking English as a second language when operating single-engine and multiengine aircraft within American airspace. Method. This research implemented a correlational design to investigate the ability of the six described instruments to predict the mean score of the criterion evaluation, which was the Examiner's Test. This test assessed the oral communication skill of student pilots on the flight portion of the terminal checkride in the Piper Cadet, Piper Seminole, and Beechcraft King Air airplanes. Results. Data from the Single Manual-Tracking Test, as well as the Concurrent Manual-Tracking and Communication Test, were discarded due to performance ceiling effects. Hypothesis 1, which stated that the average correlation between the mean scores of the dual-task evaluations and that of the Examiner's Test would predict the mean score of the criterion evaluation with a greater degree of accuracy than that of single-task evaluations, was not supported. Hypothesis 2, which stated that the correlation between the mean scores of the participants on the Simulation-Based English Test and the Examiner's Test would predict the mean score of the criterion evaluation with a greater degree of accuracy than that of all single- and dual-task evaluations, was also not supported. The findings suggest that single- and dual-task assessments administered after initial flight training are equivalent predictors of language performance when piloting single-engine and multiengine aircraft.
Evaluation of a new computerized psychometric test battery: Effects of zolpidem and caffeine.
Pilli, Raveendranadh; Naidu, Mur; Pingali, Usharani; Shobha, Jc
2013-10-01
To evaluate the effects of centrally active drugs using a new indigenously developed automated psychometric test system and compare the results with that obtained using pencil- and paper-based techniques. The tests were standardized in 24 healthy participants. Reproducibility of the test procedure was evaluated by performing the tests by a single experimenter on two occasions (interday reproducibility). To evaluate the sensitivity of the tests, the effects of zolpidem (5 mg) and caffeine (500 mg) versus placebo were studied in 24 healthy participants in a randomized, double-blind three-way crossover design. Psychometric tests were performed at baseline and at 1, 2, and 3 h after administration of study medication. The effects of zolpidem and caffeine on the psychomotor performance were most pronounced 1 h after administration. At this time, a significant impairment of performance in the simple reaction test (SRT), choice discrimination test (CDT), digit symbol substitution test (DSST), digit vigilance test (DVT), and card sorting test (CST) was observed with zolpidem. In contrast, caffeine showed a significant improvement in performance in CDT and DVT only. The results suggest that the tests of the computerized system are more sensitive and reliable then the pencil and paper tests in detecting the effects of central acting agents and are suitable for use in clinical areas to conduct studies with patients.
Evaluating rodent motor functions: Which tests to choose?
Schönfeld, Lisa-Maria; Dooley, Dearbhaile; Jahanshahi, Ali; Temel, Yasin; Hendrix, Sven
2017-12-01
Damage to the motor cortex induced by stroke or traumatic brain injury (TBI) can result in chronic motor deficits. For the development and improvement of therapies, animal models which possess symptoms comparable to the clinical population are used. However, the use of experimental animals raises valid ethical and methodological concerns. To decrease discomfort by experimental procedures and to increase the quality of results, non-invasive and sensitive rodent motor tests are needed. A broad variety of rodent motor tests are available to determine deficits after stroke or TBI. The current review describes and evaluates motor tests that fall into three categories: Tests to evaluate fine motor skills and grip strength, tests for gait and inter-limb coordination and neurological deficit scores. In this review, we share our thoughts on standardized data presentation to increase data comparability between studies. We also critically evaluate current methods and provide recommendations for choosing the best behavioral test for a new research line. Copyright © 2017 Elsevier Ltd. All rights reserved.
Isokinetic Testing in Evaluation Rehabilitation Outcome After ACL Reconstruction.
Cvjetkovic, Dragana Dragicevic; Bijeljac, Sinisa; Palija, Stanislav; Talic, Goran; Radulovic, Tatjana Nozica; Kosanovic, Milkica Glogovac; Manojlovic, Slavko
2015-02-01
Numerous rehab protocols have been used in rehabilitation after ACL reconstruction. Isokinetic testing is an objective way to evaluate dynamic stability of the knee joint that estimates the quality of rehabilitation outcome after ACL reconstruction. Our investigation goal was to show importance of isokinetic testing in evaluation thigh muscle strength in patients which underwent ACL reconstruction and rehabilitation protocol. In prospective study, we evaluated 40 subjects which were divided into two groups. Experimental group consisted of 20 recreational males which underwent ACL reconstruction with hamstring tendon and rehabilitation protocol 6 months before isokinetic testing. Control group (20 subjects) consisted of healthy recreational males. In all subjects knee muscle testing was performed on a Biodex System 4 Pro isokinetic dynamo-meter et velocities of 60°/s and 180°/s. We followed average peak torque to body weight (PT/BW) and classic H/Q ratio. In statistical analysis Student's T test was used. There were statistically significant differences between groups in all evaluated parameters except of the mean value of PT/BW of the quadriceps et velocity of 60°/s (p>0.05). Isokinetic testing of dynamic stabilizers of the knee is need in diagnostic and treatment thigh muscle imbalance. We believe that isokinetic testing is an objective parameter for return to sport activities after ACL reconstruction.
Bench-Scale Trace Contaminant Testing of SA9T at Ambient and Reduced Pressure Conditions
NASA Technical Reports Server (NTRS)
Broerman, Craig; Sweterlitsch, Jeff
2011-01-01
A principal concern for air revitalization technology in a closed loop system is the capability to control carbon dioxide (CO2) and humidity (H2O). An amine based sorbent technology, SA9T, has been evaluated for use in this application and several programs are evaluating it for use in both cabin and space suit applications. While the CO2 and H2O performance of the sorbent has been tested extensively, the question of how trace contaminants impact performance requires further evaluation. This paper presents experimental results of bench-scale SA9T testing that was performed under a variety of test conditions and with several different trace contaminants. Tests were conducted to determine if the capacity of the SA9T media to sufficiently remove CO2 and H2O is compromised after exposure to a fully saturated trace contaminant at ambient conditions. Tests also were conducted to evaluate the performance of SA9T at ambient conditions in a continuous 30-day test with a mixed trace contaminant stream. In addition, testing also evaluated the impact of CO2 and H2O removal performance at suit loop pressures (29.6 KPa/4.3 psia) during cyclic operation with a constant inlet contaminant load.
Individual class evaluation and effective teaching characteristics in integrated curricula.
Hwang, Jung Eun; Kim, Na Jin; Song, Meiying; Cui, Yinji; Kim, Eun Ju; Park, In Ae; Lee, Hye In; Gong, Hye Jin; Kim, Su Young
2017-12-12
In an integrated curriculum, multiple instructors take part in a course in the form of team teaching. Accordingly, medical schools strive to manage each course run by numerous instructors. As part of the curriculum management, course evaluation is conducted, but a single, retrospective course evaluation does not comprehensively capture student perception of classes by different instructors. This study aimed to demonstrate the need for individual class evaluation, and further to identify teaching characteristics that instructors need to keep in mind when preparing classes. From 2014 to 2015, students at one medical school left comments on evaluation forms after each class. Courses were also assessed after each course. Their comments were categorized by connotation (positive or negative) and by subject. Within each subject category, test scores were compared between positively and negatively mentioned classes. The Mann-Whitney U test was performed to test group differences in scores. The same method was applied to the course evaluation data. Test results for course evaluation showed group difference only in the practice/participation category. However, test results for individual class evaluation showed group differences in six categories: difficulty, main points, attitude, media/contents, interest, and materials. That is, the test scores of classes positively mentioned in six domains were significantly higher than those of negatively mentioned classes. It was proved that individual class evaluation is needed to manage multi-instructor courses in integrated curricula of medical schools. Based on the students' extensive feedback, we identified teaching characteristics statistically related to academic achievement. School authorities can utilize these findings to encourage instructors to develop effective teaching characteristics in class preparation.
Comparative Evaluation of Quantitative Test Methods for Gases on a Hard Surface
2017-02-01
COMPARATIVE EVALUATION OF QUANTITATIVE TEST METHODS FOR GASES ON A HARD SURFACE ECBC-TR-1426 Vipin Rastogi...1 COMPARATIVE EVALUATION OF QUANTITATIVE TEST METHODS FOR GASES ON A HARD SURFACE 1. INTRODUCTION Members of the U.S. Environmental...Generator 4 2.4 Experimental Design Each quantitative method was performed three times on three consecutive days. For the CD runs, three
Optimizing Department of Defense Acquisition Development Test and Evaluation Scheduling
2015-06-01
CPM Critical Path Method DOD Department of Defense DT&E development test and evaluation EMD engineering and manufacturing development GAMS...these, including the Program Evaluation Review Technique (PERT), the Critical Path Method ( CPM ), and the resource- constrained project-scheduling...problem (RCPSP). These are of particular interest to this thesis as the current scheduling method uses elements of the PERT/ CPM , and the test
Evaluation of the Field Test of Project Information Packages: Volume III--Resource Cost Analysis.
ERIC Educational Resources Information Center
Al-Salam, Nabeel; And Others
The third of three volumes evaluating the first year field test of the Project Information Packages (PIPs) provides a cost analysis study as a key element in the total evaluation. The resource approach to cost analysis is explained and the specific resource methodology used in the main cost analysis of the 19 PIP field-test projects detailed. The…
ERIC Educational Resources Information Center
Au, Wayne
2011-01-01
Current and former leaders of many major urban school districts, including Washington, D.C.'s Michelle Rhee and New Orleans' Paul Vallas, have sought to use tests to evaluate teachers. In fact, the use of high-stakes standardized tests to evaluate teacher performance in the manner of value-added measurement (VAM) has become one of the cornerstones…
Director, Operational Test and Evaluation
2007-12-01
important, and all – collectively – are necessary to properly set requirements, incentivize industry, oversee system design and development, and finally...evaluation planning which defines testing required for all system-level evaluation. • Enable access to all system-level test data by government DT...responsible for sustainment cost estimates, and with the OTAs, to contribute relevant data. As with all new missions, there is a question of resources
Quantitative evaluation research of glare from automotive headlamps
NASA Astrophysics Data System (ADS)
Wang, Tiecheng; Qian, Rui; Cao, Ye; Gao, Mingqiu
2018-01-01
This study concerns the quantized evaluation research of glare from automotive headlamps. In the actual regulations, only one point in the test screen is set for judging whether driver can bear the light caused by headlamps of opposing vehicle. To evaluating practical effect of glare, we accept a glare zone with the probability distribution information of the oncoming driver's eye position. In this focus area, glare level of headlamp is represented by weighted luminous flux. To confirm the most comfortable illuminance value to human eyes at 50 m, we used test point B50L as observation position, and collected 1,000 subjective evaluation data from 20 test personnel in different ages during two months. Basing on the assessment results, we calculated 0.60 lx as recommended value for standardized testing procedure at 25 m. Then we figured out 0.38 lm as optimum value, and 0.25 / 1.20 lm as limiting values depending on regulations. We tested 40 sample vehicles with different levels to verify the sectional nonlinear quantitative evaluation method we designed, and analyzed the typical test results.
Code of Federal Regulations, 2010 CFR
2010-07-01
... DEVICES Test Procedures and Evaluation Criteria Durability Test Procedures § 610.52 Maintenance. (a) Maintenance during the durability evaluation can best be considered in three separate categories: (1) Normal... durability evaluation in this program will probably have considerable mileage accumulation and unknown...
Implementation of testing equipment for asphalt materials.
DOT National Transportation Integrated Search
2009-05-01
Three new automated methods for related asphalt testing were evaluated under this study in an effort to save time and reduce variability in testing. The Therymolyne SSDetect, Instrotek CoreLok and Instrotek CoreDry devices were evaluated throughout t...
Implementation of Testing Equipment for Asphalt Materials
DOT National Transportation Integrated Search
2009-05-01
Three new automated methods for related asphalt testing were evaluated under this study in an effort to save time and reduce variability in testing. The Therymolyne SSDetect, Instrotek CoreLok and Instrotek CoreDry devices were evaluated throughout t...
Extra-Vehicular Activity (EVA) glove evaluation test protocol
NASA Technical Reports Server (NTRS)
Hinman-Sweeney, E. M.
1994-01-01
One of the most critical components of a space suit is the gloves, yet gloves have traditionally presented significant design challenges. With continued efforts at glove development, a method for evaluating glove performance is needed. This paper presents a pressure-glove evaluation protocol. A description of this evaluation protocol, and its development is provided. The protocol allows comparison of one glove design to another, or any one design to bare-handed performance. Gloves for higher pressure suits may be evaluated at current and future design pressures to drive out differences in performance due to pressure effects. Using this protocol, gloves may be evaluated during design to drive out design problems and determine areas for improvement, or fully mature designs may be evaluated with respect to mission requirements. Several different test configurations are presented to handle these cases. This protocol was run on a prototype glove. The prototype was evaluated at two operating pressures and in the unpressurized state, with results compared to bare-handed performance. Results and analysis from this test series are provided, as is a description of the configuration used for this test.
DOT National Transportation Integrated Search
2008-01-01
This research involved a detailed laboratory study of a new test method for evaluating road base materials based on : the strength of the soil binder. In this test method, small test specimens (5.0in length and 0.75in square cross : section) of binde...
Final Technical Report 1976-1977. Systemwide Evaluation. Publication Number: 76.69.
ERIC Educational Resources Information Center
Austin Independent School District, TX. Office of Research and Evaluation.
A series of reports describes the activities of the Office of Research and Evaluation and compiles data descriptive of the Austin (Texas) Independent School District. This report consists of four appendices, one for each of four test batteries: California Achievement Tests, Sequential Tests of Educational Progress, Boehm Tests of Basic Concepts,…
Engineering evaluation of 24 channel multispectral scanner. [from flight tests
NASA Technical Reports Server (NTRS)
Lambeck, P. F.
1973-01-01
The results of flight tests to evaluate the performance of the 24 channel multispectral scanner are reported. The flight plan and test site are described along with the time response and channel registration. The gain and offset drift, and moire patterns are discussed. Aerial photographs of the test site are included.
Marking Strategies in Metacognition-Evaluated Computer-Based Testing
ERIC Educational Resources Information Center
Chen, Li-Ju; Ho, Rong-Guey; Yen, Yung-Chin
2010-01-01
This study aimed to explore the effects of marking and metacognition-evaluated feedback (MEF) in computer-based testing (CBT) on student performance and review behavior. Marking is a strategy, in which students place a question mark next to a test item to indicate an uncertain answer. The MEF provided students with feedback on test results…
NASA Technical Reports Server (NTRS)
2009-01-01
This Interim Standard establishes requirements for evaluation, testing, and selection of materials that are intended for use in space vehicles, associated Ground Support Equipment (GSE), and facilities used during assembly, test, and flight operations. Included are requirements, criteria, and test methods for evaluating the flammability, offgassing, and compatibility of materials.
(De)Grading the Standardized Test: Can Standardized Testing Evaluate Schools?
ERIC Educational Resources Information Center
Simmons, Nicola E.
2004-01-01
Standardized testing is an assessment strategy that evaluates all students and all schools on the same basic skills and, therefore, might reasonably indicate which schools are high performers and which are not. Standardized testing is not a new strategy for providing this proof. The United States has produced reams of articles criticizing…
40 CFR 80.165 - Certification test procedures and standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., “Standard Test Method for Evaluating Unleaded Automotive Spark-Ignition Engine Fuel for Electronic Port Fuel.... The required test fuel must produce the accumulation of less than 100 mg of intake valve deposits on... Board, “Test Method for Evaluating Port Fuel Injector (PFI) Deposits in Vehicle Engines”, March 1, 1991...
40 CFR 80.165 - Certification test procedures and standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., “Standard Test Method for Evaluating Unleaded Automotive Spark-Ignition Engine Fuel for Electronic Port Fuel.... The required test fuel must produce the accumulation of less than 100 mg of intake valve deposits on... Board, “Test Method for Evaluating Port Fuel Injector (PFI) Deposits in Vehicle Engines”, March 1, 1991...
Teaching Study Skills and Test-Taking Strategies to Elementary School Students.
ERIC Educational Resources Information Center
Beidel, Deborah C.; Turner, Samuel M.; Taylor-Ferreira, Jill C.
1999-01-01
Presents and evaluates a pilot program to reduce test anxiety and related social-evaluative concerns. The Testbusters program teaches effective study habits, study skills, and test-taking strategies for children in grades 4 through 7. Results indicate that Testbusters decreased general levels of test anxiety and improved overall grade point…
NASA Technical Reports Server (NTRS)
1981-01-01
The Sunmaster DEC 8A Large Manifold solar collector using simulated conditions was evaluated. The collector provided 17.17 square feet of gross collector area. Test conditions, test requirements, an analysis of results, and tables of test data are reported.
Study of emissions from passenger cars in six cities, FY79. Volume I. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1980-10-01
The standard mass emission test (Federal Test Procedure) was performed for emission factors determination on samples of passenger cars operating in Los Angeles, Houston, Denver, Phoenix, St. Louis and Washington, DC. These samples were also used for obtaining abbreviated emission test (short cycle test), fuel economy test, emission related maintenance and other data. Two-thousand forty-two (2,042) vehicles were tested under the program. The FTP and the Highway Fuel Economy Test were performed on all vehicles at all sites. Some vehicles which exceed Federal standards (excluding the Houston site) were subjected to a restorative maintenance evaluation. The evaluation employed in Losmore » Angeles was designed to address three-way catalyst technology. Some vehicles in all but the Los Angeles site were used to evaluate commercial repair facility performance in relation to idle speed and mixture adjustments. Other actions were taken in relation to each vehicle tested. These included an emission control system maladjustment/disablement and status inspection driveability evaluations and owner interviews to obtain vehicle maintenance and usage data.« less
Indoor test for thermal performance evaluation on the Sunworks (air) solar collector
NASA Technical Reports Server (NTRS)
1978-01-01
The test procedure used and the results obtained from an evaluation test program conducted to obtain thermal performance data on a Sunworks single glazed air solar collector under simulated conditions are described. A time constant test and incident angle modifier test were conducted to determine the transient effect and the incident angle effect on the collector. These results and the results of the collector load test are also discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, N.; Davis, S.
1979-07-01
Performance and handling tests on the Calspan RSV were performed in Italy by the Istituto Sperimentale Auto E Motori (ISAM) and in West Germany by Volkswagenwerk AG Wolfsburg. The ISAM tests evaluated the Calspan RSV in the areas of fuel economy, vehicle response, braking and handling, and driver environment. The Volkswagen tests evaluated the Calspan RSV in the areas of braking, steering, handling, and overturning immunity. The ISAM tests are unlike any previously used to evaluate American vehicles. Therefore, the Calspan RSV results are compared to those of ten European cars which had undergone identical tests. The Volkswagen test proceduresmore » were identical to those specified in the Research Safety Vehicle program. The Calspan RSV results are compared to the RSV specifications for these tests.« less
Financial comparison of three testing strategies for detection of estrus in dairy cattle.
Mohammed, H O; Loefler, S; Shearer, J
1990-03-15
Three commercial tests that measure progesterone content in milk were evaluated for accuracy of estrus detection. The tests were evaluated on 96 milk samples collected from Holstein cows at a commercial dairy farm in central Florida. The test results were compared with the results of radioimmunoassay on the same sample. Comparisons were made by calculating the sensitivities, specificities, and predictive values. The significance of the statistical association between the tests and the radioimmunoassay was evaluated by use of the McNemar chi 2 test. Decision-tree analysis was used to determine the most useful testing strategy, considering both cost and accuracy. The cowside progesterone assay on estrus-mount detector-positive cows was more profitable than use of estrus-mount patches alone. The return on investment was higher with the cowside test, making it preferred as a field test for detecting estrus.
NASA Technical Reports Server (NTRS)
Sandifer, J. P.; Denny, A.; Wood, M. A.
1985-01-01
Technical issues associated with fuel containment and damage tolerance of composite wing structures for transport aircraft were investigated. Material evaluation tests were conducted on two toughened resin composites: Celion/HX1504 and Celion/5245. These consisted of impact, tension, compression, edge delamination, and double cantilever beam tests. Another test series was conducted on graphite/epoxy box beams simulating a wing cover to spar cap joint configuration of a pressurized fuel tank. These tests evaluated the effectiveness of sealing methods with various fastener types and spacings under fatigue loading and with pressurized fuel. Another test series evaluated the ability of the selected coatings, film, and materials to prevent fuel leakage through 32-ply AS4/2220-1 laminates at various impact energy levels. To verify the structural integrity of the technology demonstration article structural details, tests were conducted on blade stiffened panels and sections. Compression tests were performed on undamaged and impacted stiffened AS4/2220-1 panels and smaller element tests to evaluate stiffener pull-off, side load and failsafe properties. Compression tests were also performed on panels subjected to Zone 2 lightning strikes. All of these data were integrated into a demonstration article representing a moderately loaded area of a transport wing. This test combined lightning strike, pressurized fuel, impact, impact repair, fatigue and residual strength.
Schleifer, Sebastian G; Willemse, Ton
2003-06-01
To evaluate skin test reactivity to environmental allergens in healthy cats and in cats with atopic dermatitis (AD). 10 healthy cats and 10 cats with AD. 10 allergens in serial dilutions were injected ID on the lateral aspect of the thorax of sedated cats. Histamine (0.01% solution) and buffer solutions were used as positive and negative controls, respectively. Immediately after the last injection, 10% fluorescein solution was administered IV. Skin test results were evaluated with ultraviolet light after 15 to 30 minutes and at 4 and 6 hours by 2 independent observers. In the control group, skin tests were repeated after 6 weeks. Skin test reactivity and the nature of the immunoglobulin involved were investigated by use of the Prausnitz-Küstner test with untreated and heat-treated cat sera. Intertest and interobserver agreement were high when measurement of the diameter of the fluorescent wheal was used to evaluate skin test responses, compared with assessment of its intensity. In both groups of cats, immediate skin test reactivity was observed as an IgE-mediated reaction, as an IgG-mediated reaction, and as a result of nonspecific mast cell degranulation. There was no correlation between allergen concentration and the type of reaction observed. Skin test reactivity in cats should be evaluated after IV administration of 10% fluorescein solution by means of a Prausnitz-Küstner test to differentiate among IgE-mediated, IgG-mediated, and nonspecific reactions.
Koppelman, Marco H G M; Cuijpers, H Theo M; Wessberg, Susanna; Valkeajärvi, Anne; Pichl, Lutz; Schottstedt, Volkmar; Saldanha, John
2012-07-01
Three European laboratories evaluated the TaqScreen DPX test (DPX test), a multiplex nucleic acid test assay for the simultaneous detection and quantitation of parvovirus B19 (B19V) DNA and the detection of hepatitis A virus (HAV) RNA. The 95% limit of detection of the test for B19V and HAV was determined using the respective WHO International Standards. The reproducibility of the test was evaluated by testing replicate samples of B19V at log 4.0 and 40 IU/mL and HAV at 5 IU/mL. The accuracy of the DPX test for B19V was evaluated by replicate testing of B19V samples containing log 3.0, log 4.0, and log 5.0 IU/mL. Panels of B19V Genotypes 1, 2, and 3 and HAV genotypes were evaluated. Cross-contamination was evaluated. For comparison of the DPX test and the established tests, the sites tested plasma samples in pools of either 96 or 480 donations. The mean 95% lower limits of detection of the three laboratories for B19V and HAV were 20.30 and 1.85 IU/mL. The test showed good reproducibility with the major part of the variance of the test being attributed to intermediate assay variation. The test showed great accuracy for B19V, especially at log 4.0 IU/mL. Spiking of test pools of 480 donations and manufacturing pools with log 4.0 IU/mL B19 DNA and 4 IU/mL HAV RNA showed that the DPX assay was robust. The test was able to detect the three genotypes of B19V and HAV genotypes. No cross-contamination was seen. Test results of routine samples correlated well with those of the established tests. The DPX test is a robust and sensitive test for the detection of B19V and HAV in plasma samples. The quantitative B19V results obtained with the test are accurate, and the test is able to detect all the known genotypes of B19V and HAV and fulfills all the European Pharmacopoeia and Food and Drug Administration requirements for a B19V and HAV test for screening of plasma donations and samples from plasma pools for manufacture. © 2012 American Association of Blood Banks.
Development and applications of nondestructive evaluation at Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
Whitaker, Ann F.
1990-01-01
A brief description of facility design and equipment, facility usage, and typical investigations are presented for the following: Surface Inspection Facility; Advanced Computer Tomography Inspection Station (ACTIS); NDE Data Evaluation Facility; Thermographic Test Development Facility; Radiographic Test Facility; Realtime Radiographic Test Facility; Eddy Current Research Facility; Acoustic Emission Monitoring System; Advanced Ultrasonic Test Station (AUTS); Ultrasonic Test Facility; and Computer Controlled Scanning (CONSCAN) System.
Aircraft Survivability: Live Fire Test and Evaluation, Spring 2010
2010-01-01
OCPD ). These devices were examined in this program for their potential to reduce fire vulnerability. Testing for this test series, designated Live...divided into three categories: 1) short circuit, 2) separating arc gap, and 3) 90% conductor diameter reduction. The performance of the OCPDs was also...incorporated a production- representative tank configuration. All test configurations were evaluated with OCPD protection. In ballistic damage tests
ERIC Educational Resources Information Center
Puhan, Gautam; Boughton, Keith A.; Kim, Sooyeon
2005-01-01
The study evaluated the comparability of two versions of a teacher certification test: a paper-and-pencil test (PPT) and computer-based test (CBT). Standardized mean difference (SMD) and differential item functioning (DIF) analyses were used as measures of comparability at the test and item levels, respectively. Results indicated that effect sizes…
Henderson, Joseph W; Kane, Sarah M; Mangel, Jeffrey M; Kikano, Elias G; Garibay, Jorge A; Pollard, Robert R; Mahajan, Sangeeta T; Debanne, Sara M; Hijaz, Adonis K
2018-06-01
The cough stress test is a common and accepted tool to evaluate stress urinary incontinence but there is no agreement on how the test should be performed. We assessed the diagnostic ability of different cough stress tests performed when varying patient position and bladder volume using urodynamic stress urinary incontinence as the gold standard. The 24-hour pad test was also evaluated. We recruited women who presented to specialty outpatient clinics with the complaint of urinary incontinence and who were recommended to undergo urodynamic testing. A total of 140 patients were randomized to 4 cough stress test groups, including group 1-a comfortably full bladder, group 2-an empty bladder, group 3- a bladder infused with 200 cc saline and group 4-a bladder filled to half functional capacity. The sequence of standing and sitting was randomly assigned. The groups were compared by 1-way ANOVA or the generalized Fisher exact test. The κ statistic was used to evaluate agreement between the sitting and standing positions. The 95% CIs of sensitivity and specificity were calculated using the Wilson method. ROC analysis was done to evaluate the performance of the 24-hour pad test. The cough stress test performed with a bladder filled to half functional capacity was the best performing test with 83% sensitivity and 90% specificity. There was no statistically significant evidence that the sensitivity or specificity of 1 cough stress test differed from that of the others. The pad test had no significant predictive ability to diagnose urodynamic stress urinary incontinence (AUC 0.60, p = 0.08). Cough stress tests were accurate to diagnose urodynamic stress urinary incontinence. The 24-hour pad test was not predictive of urodynamic stress urinary incontinence and not helpful when used in conjunction with the cough stress test. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
[Impact of a training model for the Child Development Evaluation Test in primary care].
Rizzoli-Córdoba, Antonio; Delgado-Ginebra, Ismael; Cruz-Ortiz, Leopoldo Alfonso; Baqueiro-Hernández, César Iván; Martain-Pérez, Itzamara Jacqueline; Palma-Tavera, Josuha Alexander; Villasís-Keever, Miguel Ángel; Reyes-Morales, Hortensia; O'Shea-Cuevas, Gabriel; Aceves-Villagrán, Daniel; Carrasco-Mendoza, Joaquín; Antillón-Ocampo, Fátima Adriana; Villagrán-Muñoz, Víctor Manuel; Halley-Castillo, Elizabeth; Vargas-López, Guillermo; Muñoz-Hernández, Onofre
The Child Development Evaluation (CDE) Test is a screening tool designed and validated in Mexico for the early detection of child developmental problems. For professionals who will be administering the test in primary care facilities, previous acquisition of knowledge about the test is required in order to generate reliable results. The aim of this work was to evaluate the impact of a training model for primary care workers from different professions through the comparison of knowledge acquired during the training course. The study design was a before/after type considering the participation in a training course for the CDE test as the intervention. The course took place in six different Mexican states from October to December 2013. The same questions were used before and after. There were 394 participants included. Distribution according to professional profile was as follows: general physicians 73.4%, nursing 7.7%, psychology 7.1%, nutrition 6.1% and other professions 5.6%. The questions with the lowest correct answer rates were associated with the scoring of the CDE test. In the initial evaluation, 64.9% obtained a grade lower than 20 compared with 1.8% in the final evaluation. In the initial evaluation only 1.8% passed compared with 75.15% in the final evaluation. The proposed model allows the participants to acquire general knowledge about the CDE Test. To improve the general results in future training courses, it is required to reinforce during training the scoring and interpretation of the test together with the previous lecture of the material by the participants. Copyright © 2015 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.
Evaluation of pro-convulsant risk in the rat: spontaneous and provoked convulsions.
Esneault, Elise; Peyon, Guillaume; Froger-Colléaux, Christelle; Castagné, Vincent
2015-01-01
The aim of the present study was to evaluate the utility of different tests performed in the absence or presence of factors promoting seizures in order to evaluate the pro-convulsant effects of drugs. We studied the effects of theophylline in the rat since this is a well-known pro-convulsant substance in humans. The occurrence of spontaneous convulsions following administration of theophylline was evaluated by observation in the Irwin Test and by measuring brain activity using video-EEG recording in conscious telemetered animals. Theophylline was also tested in the electroconvulsive shock (ECS) threshold and pentylenetetrazole (PTZ)-induced convulsions tests, two commonly used models of provoked convulsions. In the Irwin test, theophylline induced convulsions in 1 out of 6 rats at 128 mg/kg. Paroxysmal/seizure activity was also observed by video-EEG recording in 4 out of the 12 animals tested at 128 mg/kg, in presence of clonic convulsions in 3 out of the 4 rats. Paroxysmal activity was observed in two rats in the absence of clear behavioral symptoms, indicating that some precursor signs can be detected using video-EEG. Clear pro-convulsant activity was shown over the dose-range 32-128 mg/kg in the ECS threshold and PTZ-induced convulsions tests. Evaluation of spontaneous convulsions provides information on the therapeutic window of a drug and the translational value of the approach is increased by the use of video-EEG. Tests based on provoked convulsions further complement the evaluation since they try to mimic high risk situations. Measurement of both spontaneous and provoked convulsions improves the evaluation of the pro-convulsant risk of novel pharmacological substances. Copyright © 2014 Elsevier Inc. All rights reserved.
Fatigue Test Design: Scenarios for Biaxial Fatigue Testing of a 60-Meter Wind Turbine Blade
DOE Office of Scientific and Technical Information (OSTI.GOV)
Post, Nathan
Current practice in commercial certification of wind turbine blades is to perform separate flap and lead-lag fatigue tests. The National Renewable Energy Laboratory has been researching and evaluating biaxial fatigue testing techniques and demonstrating various options, typically on smaller-scale test articles at the National Wind Technology Center. This report evaluates some of these biaxial fatigue options in the context of application to a multimegawatt blade certification test program at the Wind Technology Testing Center in Charlestown, Massachusetts.
2015-07-01
annex. iii Self-defense testing was limited to structural test firing from each machine gun mount and an ammunition resupply drill. Robust self...provided in the classified annex. Self- 8 defense testing was limited to structural test firing from each machine gun mount and a single...Caliber Machine Gun Mount Structural Test Fire November 2014 San Diego, Offshore Ship Weapons Range Operating Independently 9 Section Three
NASA Technical Reports Server (NTRS)
Hozman, Aron D.; Hughes, William O.
2014-01-01
The exposure of a customer's aerospace test-article to a simulated acoustic launch environment is typically performed in a reverberant acoustic test chamber. The acoustic pre-test runs that will ensure that the sound pressure levels of this environment can indeed be met by a test facility are normally performed without a test-article dynamic simulator of representative acoustic absorption and size. If an acoustic test facility's available acoustic power capability becomes maximized with the test-article installed during the actual test then the customer's environment requirement may become compromised. In order to understand the risk of not achieving the customer's in-tolerance spectrum requirement with the test-article installed, an acoustic power margin evaluation as a function of frequency may be performed by the test facility. The method for this evaluation of acoustic power will be discussed in this paper. This method was recently applied at the NASA Glenn Research Center Plum Brook Station's Reverberant Acoustic Test Facility for the SpaceX Falcon 9 Payload Fairing acoustic test program.
NASA Technical Reports Server (NTRS)
Hozman, Aron D.; Hughes, William O.
2014-01-01
The exposure of a customers aerospace test-article to a simulated acoustic launch environment is typically performed in a reverberant acoustic test chamber. The acoustic pre-test runs that will ensure that the sound pressure levels of this environment can indeed be met by a test facility are normally performed without a test-article dynamic simulator of representative acoustic absorption and size. If an acoustic test facilitys available acoustic power capability becomes maximized with the test-article installed during the actual test then the customers environment requirement may become compromised. In order to understand the risk of not achieving the customers in-tolerance spectrum requirement with the test-article installed, an acoustic power margin evaluation as a function of frequency may be performed by the test facility. The method for this evaluation of acoustic power will be discussed in this paper. This method was recently applied at the NASA Glenn Research Center Plum Brook Stations Reverberant Acoustic Test Facility for the SpaceX Falcon 9 Payload Fairing acoustic test program.
Determinants of maximal oxygen uptake (VO2 max) in fire fighter testing.
Vandersmissen, G J M; Verhoogen, R A J R; Van Cauwenbergh, A F M; Godderis, L
2014-07-01
The aim of this study was to evaluate current daily practice of aerobic capacity testing in Belgian fire fighters. The impact of personal and test-related parameters on the outcome has been evaluated. Maximal oxygen uptake (VO2 max) results of 605 male fire fighters gathered between 1999 and 2010 were analysed. The maximal cardio respiratory exercise tests were performed at 22 different centres using different types of tests (tread mill or bicycle), different exercise protocols and measuring equipment. Mean VO2 max was 43.3 (SD = 9.8) ml/kg.min. Besides waist circumference and age, the type of test, the degree of performance of the test and the test centre were statistically significant determinants of maximal oxygen uptake. Test-related parameters have to be taken into account when interpreting and comparing maximal oxygen uptake tests of fire fighters. It highlights the need for standardization of aerobic capacity testing in the medical evaluation of fire fighters. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Thermal performance of MSFC hot air collectors under natural and simulated conditions
NASA Technical Reports Server (NTRS)
Shih, K., Sr.
1977-01-01
The procedures used and the results obtained from an evaluation test program conducted to determine the thermal performance and structural characteristics of selected MSFC--designed hot air collectors under both real and simulated environmental conditions are described. Five collectors were tested in the three phased program. A series of outdoor tests were conducted to determine stagnation temperatures on a typical bright day and to determine each collector's ability to withstand these temperatures. Two of the collectors experienced structural deformation sufficient to eliminate them from the remainder of the test program. A series of outdoor tests to evaluate the thermal performance of collector S/N 10 under certain test conditions were performed followed by a series of indoor tests to evaluate the thermal performance of the collector under closely controlled simulated conditions.
The USEPA's National Homeland Security Research Center (NHSRC)Technology Testing and Evaluation Program (TTEP) is carrying out performance tests on homeland security technologies. Under TTEP, Battelle recently evaluated the performance of the Science Applications International Co...
Evaluation of TravInfo field operational test
DOT National Transportation Integrated Search
2000-04-25
This document constitutes the final report of the evaluation of the TravInfo field operational test. TravInfo is a regional traveler information system in operation in the San Francisco Bay Area. The focus of the evaluation was on three areas: instit...
SITE PROGRAM EVALUATION OF THE SONOTECH PULSE COMBUSTION BURNER TECHNOLOGY - TECHNICAL RESULTS
A series of demonstration tests was performed at the Environmental Protection Agency's (EPA's) Incineration Research Facility (IRF) under the Superfund Innovative Technology Evaluation (SITE) program. These tests, twelve in all, evaluated a pulse combustion burner technology dev...
Strategic plan for the FleetForward evaluation : technical memorandum
DOT National Transportation Integrated Search
1999-04-01
This document is the final report for the evaluation of the I-95 Corridor Coalitions FleetForward operational test. The objective of this test was to evaluate the usefulness of traffic flow data to motor carrier operations. Cambridge Systematics, in ...
Fuzzy logic based sensor performance evaluation of vehicle mounted metal detector systems
NASA Astrophysics Data System (ADS)
Abeynayake, Canicious; Tran, Minh D.
2015-05-01
Vehicle Mounted Metal Detector (VMMD) systems are widely used for detection of threat objects in humanitarian demining and military route clearance scenarios. Due to the diverse nature of such operational conditions, operational use of VMMD without a proper understanding of its capability boundaries may lead to heavy causalities. Multi-criteria fitness evaluations are crucial for determining capability boundaries of any sensor-based demining equipment. Evaluation of sensor based military equipment is a multi-disciplinary topic combining the efforts of researchers, operators, managers and commanders having different professional backgrounds and knowledge profiles. Information acquired through field tests usually involves uncertainty, vagueness and imprecision due to variations in test and evaluation conditions during a single test or series of tests. This report presents a fuzzy logic based methodology for experimental data analysis and performance evaluation of VMMD. This data evaluation methodology has been developed to evaluate sensor performance by consolidating expert knowledge with experimental data. A case study is presented by implementing the proposed data analysis framework in a VMMD evaluation scenario. The results of this analysis confirm accuracy, practicability and reliability of the fuzzy logic based sensor performance evaluation framework.
DOT National Transportation Integrated Search
2003-10-01
The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : WSDOT deployment". This document defines the objective, approach,...
NASA Technical Reports Server (NTRS)
Mason, M. G.
1975-01-01
A simulator is described, which was designed for testing and evaluating inertial measuring units, and flight platforms. Mechanical and electrical specifications for the outer, middle, and inner axis are presented. Test results are included.
Evaluation of new binders using newly developed fracture energy test.
DOT National Transportation Integrated Search
2013-07-01
This study evaluated a total of seven asphalt binders with various additives : using the newly developed binder fracture energy test. The researchers prepared and : tested PAV-aged and RTFO-plus-PAV-aged specimens. This study confirmed previous : res...
Field evaluation of a behavioral test battery for DWI
DOT National Transportation Integrated Search
1983-09-01
This paper presents initial findings from a recently conducted field evaluation of a sobriety test battery. Police officers from four jurisdictions were trained in the use of the sobriety test battery. They then administered the battery to drivers st...
Marihuana contact test, evaluation and development
DOT National Transportation Integrated Search
1976-02-01
A colorimetric swab test for detecting human contact with marihuana was evaluated. The test was found to be capable of detecting only 83% of marihuana smokers immediately after smoking and was also demonstrated to be subject to a wide range of possib...
Testing and evaluation of sign support with cluster attachments.
DOT National Transportation Integrated Search
1990-04-01
Two full-scale crash tests were conducted on the Louisiana two-post, inclined, slip-base sign assembly with cluster sign attachment. These two tests were performed and evaluated in accordance with guidelines under NCHRP Report 230 and standards estab...
NASA Technical Reports Server (NTRS)
Guasp, Edwin; Manzo, Michelle A.
1997-01-01
Secondary alkaline batteries, such as nickel-cadmium and silver-zinc, are commonly used for aerospace applications. The uniform evaluation and comparison of separator properties for these systems is dependent upon the measurement techniques. This manual presents a series of standard test procedures that can be used to evaluate, compare, and select separator materials for use in alkaline batteries. Detailed test procedures evaluating the following characteristics are included in this manual: physical measurements of thickness and area weight, dimensional stability measurements, electrolyte retention, resistivity, permeability as measured via bubble pressure, surface evaluation via SEM, chemical stability, and tensile strength.
Student Self-evaluation After Nursing Examinations: That's a Wrap.
Butzlaff, Alice; Gaylle, Debrayh; O'Leary Kelley, Colleen
2018-04-13
Examination wrappers are a self-evaluation tool that uses metacognition to help students reflect on test performance. After examinations, rather than focus on points earned, students learn to self-identify study strategies and recognize methods of test preparation. The purpose of the study was to determine if the use of an examination wrapper after each test would encourage students to self-evaluate performance and adjust study strategies. A total of 120 undergraduate nursing students completed self-evaluations after each examination, which were analyzed using content analysis. Three general patterns emerged from student self-evaluation: effective and ineffective study strategies, understanding versus memorization of content, and nurse educator assistance.
Dissimilar metals joint evaluation
NASA Technical Reports Server (NTRS)
Wakefield, M. E.; Apodaca, L. E.
1974-01-01
Dissimilar metals tubular joints between 2219-T851 aluminum alloy and 304L stainless steel were fabricated and tested to evaluate bonding processes. Joints were fabricated by four processes: (1) inertia (friction) weldings, where the metals are spun and forced together to create the weld; (2) explosive welding, where the metals are impacted together at high velocity; (3) co-extrusion, where the metals are extruded in contact at high temperature to promote diffusion; and (4) swaging, where residual stresses in the metals after a stretching operation maintain forced contact in mutual shear areas. Fifteen joints of each type were prepared and evaluated in a 6.35 cm (2.50 in.) O.D. size, with 0.32 cm (0.13 in.) wall thickness, and 7.6 cm (3.0 in) total length. The joints were tested to evaluate their ability to withstand pressure cycle, thermal cycle, galvanic corrosion and burst tests. Leakage tests and other non-destructive test techniques were used to evaluate the behavior of the joints, and the microstructure of the bond areas was analyzed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chambon, Paul H.; Deter, Dean D.
2016-07-01
xiii ABSTRACT The goal of this project is to develop and evaluate powertrain test procedures that can accurately simulate real-world operating conditions, and to determine greenhouse gas (GHG) emissions of advanced medium- and heavy-duty engine and vehicle technologies. ORNL used their Vehicle System Integration Laboratory to evaluate test procedures on a stand-alone engine as well as two powertrains. Those components where subjected to various drive cycles and vehicle conditions to evaluate the validity of the results over a broad range of test conditions. Overall, more than 1000 tests were performed. The data are compiled and analyzed in this report.
NASA Technical Reports Server (NTRS)
Sanchez, Christopher M.
2011-01-01
NASA White Sands Test Facility (WSTF) is leading an evaluation effort in advanced destructive and nondestructive testing of composite pressure vessels and structures. WSTF is using progressive finite element analysis methods for test design and for confirmation of composite pressure vessel performance. Using composite finite element analysis models and failure theories tested in the World-Wide Failure Exercise, WSTF is able to estimate the static strength of composite pressure vessels. Additionally, test and evaluation on composites that have been impact damaged is in progress so that models can be developed to estimate damage tolerance and the degradation in static strength.
NASA Technical Reports Server (NTRS)
Harkness, J. D.
1974-01-01
An evaluation test of the 20.0 ampere-hour cells was conducted to insure that all cells put into the life cycle program are of high quality. This is accomplished by the screening of cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open circuit voltage above 1.150 volts during the internal short test. The results obtained in the test are given, as well as the recommendations based on these findings.
Christopher, David; Adams, Wallace P; Lee, Douglas S; Morgan, Beth; Pan, Ziqing; Singh, Gur Jai Pal; Tsong, Yi; Lyapustina, Svetlana
2007-01-19
The purpose of this article is to present the thought process, methods, and interim results of a PQRI Working Group, which was charged with evaluating the chi-square ratio test as a potential method for determining in vitro equivalence of aerodynamic particle size distribution (APSD) profiles obtained from cascade impactor measurements. Because this test was designed with the intention of being used as a tool in regulatory review of drug applications, the capability of the test to detect differences in APSD profiles correctly and consistently was evaluated in a systematic way across a designed space of possible profiles. To establish a "base line," properties of the test in the simplest case of pairs of identical profiles were studied. Next, the test's performance was studied with pairs of profiles, where some difference was simulated in a systematic way on a single deposition site using realistic product profiles. The results obtained in these studies, which are presented in detail here, suggest that the chi-square ratio test in itself is not sufficient to determine equivalence of particle size distributions. This article, therefore, introduces the proposal to combine the chi-square ratio test with a test for impactor-sized mass based on Population Bioequivalence and describes methods for evaluating discrimination capabilities of the combined test. The approaches and results described in this article elucidate some of the capabilities and limitations of the original chi-square ratio test and provide rationale for development of additional tests capable of comparing APSD profiles of pharmaceutical aerosols.
Dental Diamond Rotary Instruments. Test and Evaluation
1983-09-01
Gov’t. agencies only; Critical Technology; Test and Evaluation; 19 NOV 1982. Other requests shall be referred to Dental Investigation Service, School of... DENTAL DIAMOND ROTARY INSTRUMENTS Test and Evaluation Cad D. Foster, Major, USAF, DC Joseph M. Powell, Colonel, USAF, DC John M. Young, Colonel, USAF...19 November 1982. Other requests for this document must be referred to the Dental Investig tion Service, USAF School of Aerospace Medicine. SUBJECT TO
ERIC Educational Resources Information Center
Drennan, Jonathan; Hyde, Abbey
2008-01-01
Traditionally the measures used to evaluate the impact of an educational programme on student outcomes and the extent to which students change is a comparison of the student's pre-test scores with his/her post-test scores. However, this method of evaluating change may be problematic due to the confounding factor of response shift bias when student…
Software OT&E Guidelines. Volume 1. Software Test Manager’s Handbook
1981-02-01
on reverse side If neceeary and identify by block number) The Software OT&E Guidelines is a set of handbooks prepared by the Computer / Support Systems...is one of a set of handbooks prepared by the Computer /Support Systems Division of the Test and Evaluation Directorate, Air Force Test and Evaluation...15 E. Software Maintainability .. .. ........ ... 16 F. Standard Questionnaires. .. .. ....... .... 16 1. Operator- Computer Interface Evaluation
Evaluation of Two Guralp Preamplifiers for GS21 Seismometer Application.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merchant, Bion J.; Slad, George William
2015-08-01
Sandia National Laboratories has tested and evaluated two Guralp preamplifiers for use with a GS21 seismometer application. The two preamplifiers have a gain factor of 61.39. The purpose of the preamplifier evaluation was to determine a measured gain factor, transfer function, total harmonic distortion, self-noise, application passband, dynamic range, seismometer calibration pass-through, and to comment on any issues encountered during the evaluation. The test results included in this report were in response to static, tonal, and dynamic input signals. The Guralp GS21 preamplifiers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treatymore » Organization (CTBTO). Test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters« less
Evaluation of lower leg function in patients with Achilles tendinopathy.
Silbernagel, Karin Grävare; Gustavsson, Alexander; Thomeé, Roland; Karlsson, Jon
2006-11-01
Achilles tendinopathy is considered to be one of the most common overuse injuries in elite and recreational athletes. However, the effect that the Achilles tendinopathy has on patients' physical performance is still unclear. The purpose of this study was to evaluate if Achilles tendinopathy caused functional deficits on the injured side compared with the non-injured side in patients. A test battery comprised of tests for different aspects of muscle-tendon function of the gastrocnemius, soleus and Achilles tendon complex was developed to evaluate lower leg function. The test battery's test-retest reliability and sensitivity (the percent probability that the tests would demonstrate abnormal lower limb symmetry index in patients) were also evaluated. The test battery consisted of three jump tests, a counter movements jump (CMJ), a drop counter movement jump (drop CMJ) and hopping, and two strength tests, concentric toe-raises, eccentric-concentric toe-raises and toe-raises for endurance. The reliability was evaluated through a test-retest design on 15 healthy subjects. The test battery's sensitivity and possible functional deficits in patients with Achilles tendinopathy were evaluated on 42 patients (19 women and 23 men). An excellent reliability was found between test days 1-2 and 2-3 for all tests (ICC = 0.76-0.94) except for concentric toe-raise, test 2-3, which had fair reliability (ICC = 0.73). The methodological error ranged from 8 to 17%. There were significant differences (P = 0.001-0.049) between the non-injured (or least symptomatic) side and injured (most symptomatic) side for hopping, drop CMJ, concentric and eccentric-concentric toe-raises, and significant differences (P = 0.000-0.012) in the level of pain during CMJ, hopping, and drop CMJ. The sensitivity of the test battery at a 90% capacity was 88. Achilles tendinopathy causes not only pain and symptoms in patients but also apparent impairments in various aspects of lower leg muscle-tendon function as measured with the test battery. This test battery is reliable and able to detect differences in lower leg function between the injured or "most symptomatic" and non-injured or "least symptomatic" side in patients with Achilles tendinopathy. The test battery has higher demand on patients' function compared with each individual test.
ERIC Educational Resources Information Center
New York State Office of the Comptroller, Albany.
Findings of an audit of the New York State Education Department's procedures to maintain security over Pupil Evaluation Program (PEP) and Program Evaluation Test (PET) examination materials are presented in this report. The audit sought to determine whether the department's security procedures adequately prevented unauthorized access to exam…
Use of Testing/Evaluation Information for School Improvement.
ERIC Educational Resources Information Center
Ligon, Glynn
This perspective on how testing and evaluation data are used and could be used for school improvement is based partly on the experience of the Austin (Texas) Public Schools and partly on their goals. Four conditions are necessary for the effective use of evaluation information: (1) real need; (2) trust in the evaluators and in the information…
ERIC Educational Resources Information Center
Coster, Wendy J.; Kramer, Jessica M.; Tian, Feng; Dooley, Meghan; Liljenquist, Kendra; Kao, Ying-Chia; Ni, Pengsheng
2016-01-01
The Pediatric Evaluation of Disability Inventory-Computer Adaptive Test is an alternative method for describing the adaptive function of children and youth with disabilities using a computer-administered assessment. This study evaluated the performance of the Pediatric Evaluation of Disability Inventory-Computer Adaptive Test with a national…
The theory and programming of statistical tests for evaluating the Real-Time Air-Quality Model (RAM) using the Regional Air Pollution Study (RAPS) data base are fully documented in four volumes. Moreover, the tests are generally applicable to other model evaluation problems. Volu...
ERIC Educational Resources Information Center
Moses, Tim
2008-01-01
Nine statistical strategies for selecting equating functions in an equivalent groups design were evaluated. The strategies of interest were likelihood ratio chi-square tests, regression tests, Kolmogorov-Smirnov tests, and significance tests for equated score differences. The most accurate strategies in the study were the likelihood ratio tests…
Format of Options in Multiple Choice Test vis-a-vis Test Performance
ERIC Educational Resources Information Center
Bendulo, Hermabeth O.; Tibus, Erlinda D.; Bande, Rhodora A.; Oyzon, Voltaire Q.; Milla, Norberto E.; Macalinao, Myrna L.
2017-01-01
Testing or evaluation in an educational context is primarily used to measure or evaluate and authenticate the academic readiness, learning advancement, acquisition of skills, or instructional needs of learners. This study tried to determine whether the varied combinations of arrangements of options and letter cases in a Multiple-Choice Test (MCT)…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-04
... Evaluation and testing within a risk management process 2-100 ASTM E1372-95 (2003) Standard Test Method...) Standard Title, Type of Test Method for Agar Diffusion Cell standard , Relevant Culture Screening for... Biological evaluation of medical devices - Office(s) and Part 3: Tests for genotoxicity, Division(s...
TOXICITY TESTING, RISK ASSESSMENT, AND OPTIONS FOR DREDGED MATERIAL MANAGEMENT
Programs for evaluating proposed discharges of dredged material into waters of the United States specify a tiered testing and evaluation protocol that includes performance of acute and chronic bioassays to assess toxicity of the dredged sediments. Although these evaluations refl...
Cantwell, H; O'Keeffe, M
2006-02-01
The Premi Test, a test kit designed for the rapid screening of antimicrobial residues in meat, fish and eggs, was evaluated and compared with the (modified) One-Plate Test, an agar diffusion assay. The performance characteristics described for qualitative, screening methods in Commission Decision 2002/657/EC were used for the evaluation. The Premi Test was found to detect a range of antimicrobials to MRL levels in kidney fluid but to have poorer sensitivity for some antimicrobials such as tetracyclines, sulphonamides, flumequine and streptomycin. The test was found not to be sensitive for the banned antimicrobial chloramphenicol. The One-Plate Test was found to detect most tetracyclines and flumequine to MRL levels but to be less sensitive than the Premi Test for most of the other classes of antimicrobials. Neither test alone provides a comprehensive screening test for antimicrobial residues in kidney at MRL levels. However, the Premi Test is fast, easy to use and rugged and, in combination with other antimicrobial tests, may be used to provide a comprehensive screening system for antimicrobials in tissues.
40 CFR 60.53b - Standards for municipal waste combustor operating practices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... for the purpose of evaluating system performance, testing new technology or control technologies... evaluating system performance, testing new technology or control technologies, diagnostic testing, or related... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of...
DOT National Transportation Integrated Search
2004-01-01
The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : state of Utah". This document defines the objective, approach, an...
Uniform peanut performance test 2017
USDA-ARS?s Scientific Manuscript database
The Uniform Peanut Performance Tests (UPPT) are designed to evaluate the commercial potential of advanced breeding peanut lines not formally released. The tests are performed in ten locations across the peanut production belt. In this study, 2 controls and 14 entries were evaluated at 8 locations....
Evaluation of Reagent-Impregnated Coagulase-Mannitol Test Strip for Speciation of Staphylococci
Washington, John A.; Yu, Pauline K. W.
1970-01-01
A new coagulase-mannitol reagent-impregnated strip test has been evaluated with 322 Micrococcaceae. Mannitol fermentation was determined accurately by this test; however, the coagulase reaction was difficult to interpret and was subject to significant error. PMID:5418952
DOT National Transportation Integrated Search
2003-03-17
The purpose of this effort is to independently evaluate the Battelle Operational Test Team to test methods for leveraging technology and operations to improve HAZMAT transport security, safety, and operational efficiency. As such, the preceding techn...
ERIC Educational Resources Information Center
Guion, Robert M.; Ironson, Gail H.
Challenges to classical psychometric theory are examined in the context of a broader range of fundamental, derived, and intuitive measurements in psychology; the challenges include content-referenced testing, latent trait theory, and generalizability theory. A taxonomy of psychological measurement is developed, based on: (1) purposes of…
The final days of Solar Max - Lessons learned from engineering evaluation tests
NASA Technical Reports Server (NTRS)
Donnelly, Michael L.; Croft, John W.; Ward, David K.; Thames, Michael A.
1990-01-01
End-of-life engineering evaluation tests were performed on Solar Max between October and November 1989. The tests included four-wheel control law operation; reaction wheel rundowns; modular power subsystem standard power regulator unit voltage-temperature level tests; battery rundown/2nd plateau determination; high gain antenna retraction and jettison; and solar array jettison. This paper presents these tests, their results, and the lessons learned from them.
Small Engine Technology (Set) Task 8 Aeroelastic Prediction Methods
NASA Technical Reports Server (NTRS)
Eick, Chris D.; Liu, Jong-Shang
1998-01-01
AlliedSignal Engines, in cooperation with NASA LeRC, completed an evaluation of recently developed aeroelastic computer codes using test cases from the AlliedSignal Engines fan blisk database. Test data for this task includes strain gage, light probe, performance, and steady-state pressure information obtained for conditions where synchronous or flutter vibratory conditions were found to occur. Aeroelastic codes evaluated include the quasi 3-D UNSFLO (developed at MIT and modified to include blade motion by AlliedSignal), the 2-D FREPS (developed by NASA LeRC), and the 3-D TURBO-AE (under development at NASA LeRC). Six test cases each where flutter and synchronous vibrations were found to occur were used for evaluation of UNSFLO and FREPS. In addition, one of the flutter cases was evaluated using TURBO-AE. The UNSFLO flutter evaluations were completed for 75 percent radial span and provided good agreement with the experimental test data. Synchronous evaluations were completed for UNSFLO but further enhancement needs to be added to the code before the unsteady pressures can be used to predict forced response vibratory stresses. The FREPS evaluations were hindered as the steady flow solver (SFLOW) was unable to converge to a solution for the transonic flow conditions in the fan blisk. This situation resulted in all FREPS test cases being attempted but no results were obtained during the present program. Currently, AlliedSignal is evaluating integrating FREPS with our existing steady flow solvers to bypass the SFLOW difficulties. ne TURBO-AE steady flow solution provided an excellent match with the AlliedSignal Engines calibrated DAWES 3-D viscous solver. Finally, the TURBO-AE unsteady analyses also matched experimental observations by predicting flutter for the single test case evaluated.
Image quality evaluation of full reference algorithm
NASA Astrophysics Data System (ADS)
He, Nannan; Xie, Kai; Li, Tong; Ye, Yushan
2018-03-01
Image quality evaluation is a classic research topic, the goal is to design the algorithm, given the subjective feelings consistent with the evaluation value. This paper mainly introduces several typical reference methods of Mean Squared Error(MSE), Peak Signal to Noise Rate(PSNR), Structural Similarity Image Metric(SSIM) and feature similarity(FSIM) of objective evaluation methods. The different evaluation methods are tested by Matlab, and the advantages and disadvantages of these methods are obtained by analyzing and comparing them.MSE and PSNR are simple, but they are not considered to introduce HVS characteristics into image quality evaluation. The evaluation result is not ideal. SSIM has a good correlation and simple calculation ,because it is considered to the human visual effect into image quality evaluation,However the SSIM method is based on a hypothesis,The evaluation result is limited. The FSIM method can be used for test of gray image and color image test, and the result is better. Experimental results show that the new image quality evaluation algorithm based on FSIM is more accurate.
Bartholomew, Rachel A.; Ozanich, Richard M.; Arce, Jennifer S.; Engelmann, Heather E.; Heredia-Langner, Alejandro; Hofstad, Beth A.; Hutchison, Janine R.; Jarman, Kristin; Melville, Angela M.; Victry, Kristin D.
2017-01-01
There is little published data on the performance of biological indicator tests and immunoassays that could be used by first responders to determine if a suspicious powder contains a potential biothreat agent. We evaluated a range of biological indicator tests, including 3 protein tests, 2 ATP tests, 1 DNA test, and 1 FTIR spectroscopy instrument for their ability to screen suspicious powders for Bacillus anthracis (B. anthracis) spores and ricin. We also evaluated 12 immunoassays (mostly lateral flow immunoassays) for their ability to screen for B. anthracis and ricin. We used a cost-effective, statistically based test plan that allows instruments to be evaluated at performance levels ranging from 0.85 to 0.95 lower confidence bound of the probability of detection at confidence levels of 80% to 95%. We also assessed interference with 22 common suspicious powders encountered in the field. The detection reproducibility for the biological indicators was evaluated at 108 B. anthracis spores and 62.5 μg ricin, and the immunoassay detection reproducibility was evaluated at 107 spores/mL (B. anthracis) and 0.1 μg/mL (ricin). Seven out of 12 immunoassays met our most stringent criteria for B. anthracis detection, while 9 out of 12 met our most stringent test criteria for ricin detection. Most of the immunoassays also detected ricin in 3 different crude castor seed preparations. Our testing results varied across products and sample preparations, indicating the importance of reviewing performance data for specific instruments and sample types of interest for the application in order to make informed decisions regarding the selection of biodetection equipment for field use. PMID:28192054
Bartholomew, Rachel A; Ozanich, Richard M; Arce, Jennifer S; Engelmann, Heather E; Heredia-Langner, Alejandro; Hofstad, Beth A; Hutchison, Janine R; Jarman, Kristin; Melville, Angela M; Victry, Kristin D; Bruckner-Lea, Cynthia J
There is little published data on the performance of biological indicator tests and immunoassays that could be used by first responders to determine if a suspicious powder contains a potential biothreat agent. We evaluated a range of biological indicator tests, including 3 protein tests, 2 ATP tests, 1 DNA test, and 1 FTIR spectroscopy instrument for their ability to screen suspicious powders for Bacillus anthracis (B. anthracis) spores and ricin. We also evaluated 12 immunoassays (mostly lateral flow immunoassays) for their ability to screen for B. anthracis and ricin. We used a cost-effective, statistically based test plan that allows instruments to be evaluated at performance levels ranging from 0.85 to 0.95 lower confidence bound of the probability of detection at confidence levels of 80% to 95%. We also assessed interference with 22 common suspicious powders encountered in the field. The detection reproducibility for the biological indicators was evaluated at 10 8 B. anthracis spores and 62.5 μg ricin, and the immunoassay detection reproducibility was evaluated at 10 7 spores/mL (B. anthracis) and 0.1 μg/mL (ricin). Seven out of 12 immunoassays met our most stringent criteria for B. anthracis detection, while 9 out of 12 met our most stringent test criteria for ricin detection. Most of the immunoassays also detected ricin in 3 different crude castor seed preparations. Our testing results varied across products and sample preparations, indicating the importance of reviewing performance data for specific instruments and sample types of interest for the application in order to make informed decisions regarding the selection of biodetection equipment for field use.
National trends in safety performance of electronic health record systems in children's hospitals.
Chaparro, Juan D; Classen, David C; Danforth, Melissa; Stockwell, David C; Longhurst, Christopher A
2017-03-01
To evaluate the safety of computerized physician order entry (CPOE) and associated clinical decision support (CDS) systems in electronic health record (EHR) systems at pediatric inpatient facilities in the US using the Leapfrog Group's pediatric CPOE evaluation tool. The Leapfrog pediatric CPOE evaluation tool, a previously validated tool to assess the ability of a CPOE system to identify orders that could potentially lead to patient harm, was used to evaluate 41 pediatric hospitals over a 2-year period. Evaluation of the last available test for each institution was performed, assessing performance overall as well as by decision support category (eg, drug-drug, dosing limits). Longitudinal analysis of test performance was also carried out to assess the impact of testing and the overall trend of CPOE performance in pediatric hospitals. Pediatric CPOE systems were able to identify 62% of potential medication errors in the test scenarios, but ranged widely from 23-91% in the institutions tested. The highest scoring categories included drug-allergy interactions, dosing limits (both daily and cumulative), and inappropriate routes of administration. We found that hospitals with longer periods since their CPOE implementation did not have better scores upon initial testing, but after initial testing there was a consistent improvement in testing scores of 4 percentage points per year. Pediatric computerized physician order entry (CPOE) systems on average are able to intercept a majority of potential medication errors, but vary widely among implementations. Prospective and repeated testing using the Leapfrog Group's evaluation tool is associated with improved ability to intercept potential medication errors. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Evaluation of high-voltage, high-power, solid-state remote power controllers for amps
NASA Technical Reports Server (NTRS)
Callis, Charles P.
1987-01-01
The Electrical Power Branch at Marshall Space Flight Center has a Power System Development Facility where various power circuit breadboards are tested and evaluated. This project relates to the evaluation of a particular remote power controller (RPC) energizing high power loads. The Facility equipment permits the thorough testing and evaluation of high-voltage, high-power solid-state remote power controllers. The purpose is to evaluate a Type E, 30 Ampere, 200 V dc remote power controller. Three phases of the RPC evaluation are presented. The RPC is evaluated within a low-voltage, low-power circuit to check its operational capability. The RPC is then evaluated while performing switch/circuit breaker functions within a 200 V dc, 30 Ampere power circuit. The final effort of the project relates to the recommended procedures for installing these RPC's into the existing Autonomously Managed Power System (AMPS) breadboard/test facility at MSFC.
Objective speech quality evaluation of real-time speech coders
NASA Astrophysics Data System (ADS)
Viswanathan, V. R.; Russell, W. H.; Huggins, A. W. F.
1984-02-01
This report describes the work performed in two areas: subjective testing of a real-time 16 kbit/s adaptive predictive coder (APC) and objective speech quality evaluation of real-time coders. The speech intelligibility of the APC coder was tested using the Diagnostic Rhyme Test (DRT), and the speech quality was tested using the Diagnostic Acceptability Measure (DAM) test, under eight operating conditions involving channel error, acoustic background noise, and tandem link with two other coders. The test results showed that the DRT and DAM scores of the APC coder equalled or exceeded the corresponding test scores fo the 32 kbit/s CVSD coder. In the area of objective speech quality evaluation, the report describes the development, testing, and validation of a procedure for automatically computing several objective speech quality measures, given only the tape-recordings of the input speech and the corresponding output speech of a real-time speech coder.
Isokinetic Testing in Evaluation Rehabilitation Outcome After ACL Reconstruction
Cvjetkovic, Dragana Dragicevic; Bijeljac, Sinisa; Palija, Stanislav; Talic, Goran; Radulovic, Tatjana Nozica; Kosanovic, Milkica Glogovac; Manojlovic, Slavko
2015-01-01
Introduction: Numerous rehab protocols have been used in rehabilitation after ACL reconstruction. Isokinetic testing is an objective way to evaluate dynamic stability of the knee joint that estimates the quality of rehabilitation outcome after ACL reconstruction. Our investigation goal was to show importance of isokinetic testing in evaluation thigh muscle strength in patients which underwent ACL reconstruction and rehabilitation protocol. Subjects and methods: In prospective study, we evaluated 40 subjects which were divided into two groups. Experimental group consisted of 20 recreational males which underwent ACL reconstruction with hamstring tendon and rehabilitation protocol 6 months before isokinetic testing. Control group (20 subjects) consisted of healthy recreational males. In all subjects knee muscle testing was performed on a Biodex System 4 Pro isokinetic dynamo-meter et velocities of 60°/s and 180°/s. We followed average peak torque to body weight (PT/BW) and classic H/Q ratio. In statistical analysis Student’s T test was used. Results: There were statistically significant differences between groups in all evaluated parameters except of the mean value of PT/BW of the quadriceps et velocity of 60°/s (p>0.05). Conclusion: Isokinetic testing of dynamic stabilizers of the knee is need in diagnostic and treatment thigh muscle imbalance. We believe that isokinetic testing is an objective parameter for return to sport activities after ACL reconstruction. PMID:25870471
An IMU Evaluation Method Using a Signal Grafting Scheme
Niu, Xiaoji; Wang, Qiang; Li, You; Zhang, Quan; Jiang, Peng
2016-01-01
As various inertial measurement units (IMUs) from different manufacturers appear every year, it is not affordable to evaluate every IMU through tests. Therefore, this paper presents an IMU evaluation method by grafting data from the tested IMU to the reference data from a higher-grade IMU. The signal grafting (SG) method has several benefits: (a) only one set of field tests with a higher-grade IMU is needed, and can be used to evaluate numerous IMUs. Thus, SG is effective and economic because all data from the tested IMU is collected in the lab; (b) it is a general approach to compare navigation performances of various IMUs by using the same reference data; and, finally, (c) through SG, one can first evaluate an IMU in the lab, and then decide whether to further test it. Moreover, this paper verified the validity of SG to both medium- and low-grade IMUs, and presents and compared two SG strategies, i.e., the basic-error strategy and the full-error strategy. SG provided results similar to field tests, with a difference of under 5% and 19.4%–26.7% for tested tactical-grade and MEMS IMUs. Meanwhile, it was found that dynamic IMU errors were essential to guarantee the effect of the SG method. PMID:27294932
TECHNOLOGY EVALUATION REPORT CEREX ENVIRONMENTAL SERVICES UV HOUND POINT SAMPLE AIR MONITOR
The USEPA's National Homeland Security Research Center (NHSRC) Technology Testing and Evaluation Program (TTEP) is carrying out performance tests on homeland security technologies. Under TTEP, Battelle evaluated the performance of the Cerex UV Hound point sample air monitor in de...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-07
...; surveys, research and evaluation methodologies; demonstration testing and model development; synthesis and..., policy and program analysis; surveys, research and evaluation methodologies; demonstration testing and... Organization, Functions, and Delegations of Authority; Office of Planning, Research and Evaluation AGENCY...
DOT National Transportation Integrated Search
2017-04-28
The document describes the overall process for evaluating Dedicated Short Range Communication (DSRC) Roadside Units (RSU) against USDOT RSU Specification 4.1 in preparation for field evaluation. The Test Cases contained in this document only evaluate...
Use of Commercial FPGA-Based Evaluation Boards for Single-Event Testing of DDR2 and DDR3 SDRAMs
NASA Technical Reports Server (NTRS)
Ladbury, R. L.; Berg, M. D.; Wilcox, E. P.; LaBel, K. A.; Kim, H. S.; Phan, A. M.; Seidleck, C. M.
2013-01-01
We investigate the use of commercial FPGA based evaluation boards for radiation testing DDR2 and DDR3 SDRAMs. We evaluate the resulting data quality and the tradeoffs involved in the use of these boards.
Sansgiry, S S; Cady, P S
1997-01-01
Currently, marketed over-the-counter (OTC) medication labels were simulated and tested in a controlled environment to understand consumer evaluation of OTC label information. Two factors, consumers' age (younger and older adults) and label designs (picture-only, verbal-only, congruent picture-verbal, and noncongruent picture-verbal) were controlled and tested to evaluate consumer information processing. The effects exerted by the independent variables, namely, comprehension of label information (understanding) and product evaluations (satisfaction, certainty, and perceived confusion) were evaluated on the dependent variable purchase intention. Intention measured as purchase recommendation was significantly related to product evaluations and affected by the factor label design. Participants' level of perceived confusion was more important than actual understanding of information on OTC medication labels. A Label Evaluation Process Model was developed which could be used for future testing of OTC medication labels.
Boeing's CST-100 Structural Test Article Arrival - Boeing's Faci
2016-12-08
Boeing’s Structural Test Article of its CST-100 Starliner spacecraft arrives at the company’s Huntington Beach, California, facilities for evaluations. Built to the specifications of an operational spacecraft, the STA is intended to be evaluated through a series of thorough testing conditions.
40 CFR 610.24 - Validity of test data.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 30 2011-07-01 2011-07-01 false Validity of test data. 610.24 Section 610.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary...
40 CFR 610.24 - Validity of test data.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 31 2012-07-01 2012-07-01 false Validity of test data. 610.24 Section 610.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary...
40 CFR 610.24 - Validity of test data.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 30 2014-07-01 2014-07-01 false Validity of test data. 610.24 Section 610.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary...
40 CFR 610.24 - Validity of test data.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 31 2013-07-01 2013-07-01 false Validity of test data. 610.24 Section 610.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary...
46 CFR 28.505 - Vessel owner's responsibility.
Code of Federal Regulations, 2011 CFR
2011-10-01
... FISHING INDUSTRY VESSELS Stability § 28.505 Vessel owner's responsibility. (a) Where a test or calculations are necessary to evaluate stability, it is the owner's responsibility to select a qualified individual to perform the test or calculations. (b) Test results and calculations developed in evaluating...
46 CFR 28.505 - Vessel owner's responsibility.
Code of Federal Regulations, 2014 CFR
2014-10-01
... FISHING INDUSTRY VESSELS Stability § 28.505 Vessel owner's responsibility. (a) Where a test or calculations are necessary to evaluate stability, it is the owner's responsibility to select a qualified individual to perform the test or calculations. (b) Test results and calculations developed in evaluating...
46 CFR 28.505 - Vessel owner's responsibility.
Code of Federal Regulations, 2013 CFR
2013-10-01
... FISHING INDUSTRY VESSELS Stability § 28.505 Vessel owner's responsibility. (a) Where a test or calculations are necessary to evaluate stability, it is the owner's responsibility to select a qualified individual to perform the test or calculations. (b) Test results and calculations developed in evaluating...
46 CFR 28.505 - Vessel owner's responsibility.
Code of Federal Regulations, 2010 CFR
2010-10-01
... FISHING INDUSTRY VESSELS Stability § 28.505 Vessel owner's responsibility. (a) Where a test or calculations are necessary to evaluate stability, it is the owner's responsibility to select a qualified individual to perform the test or calculations. (b) Test results and calculations developed in evaluating...
46 CFR 28.505 - Vessel owner's responsibility.
Code of Federal Regulations, 2012 CFR
2012-10-01
... FISHING INDUSTRY VESSELS Stability § 28.505 Vessel owner's responsibility. (a) Where a test or calculations are necessary to evaluate stability, it is the owner's responsibility to select a qualified individual to perform the test or calculations. (b) Test results and calculations developed in evaluating...
Evaluation of the PuSHMe regional mayday system operational test : final report
DOT National Transportation Integrated Search
1997-09-01
This report is an independent evaluation of the Puget Sound Emergency Response Operational Test (PuSHMe), a test of regional mayday systems that allow a driver to signal his or her location and need for assistance to a response center.
DOT National Transportation Integrated Search
2017-04-01
This report presents a high-level test and evaluation framework for cooperative driving automation systems that have the potential to significantly improve mobility and enhance traffic flow stability with better safety. It focuses on the test and eva...
40 CFR 610.24 - Validity of test data.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Validity of test data. 610.24 Section 610.24 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary...
LABORATORY TOXICITY TESTS FOR EVALUATING POTENTIAL EFFECTS OF ENDOCRINE-DISRUPTING COMPOUNDS
The scope of the Laboratory Testing Work Group was to evaluate methods for testing aquatic and terrestrial invertebrates in the laboratory. Specifically, discussions focused on the following objectives: 1) assess the extent to which consensus-based standard methods and other pub...
Standards for Evaluating Criterion-Referenced Tests.
ERIC Educational Resources Information Center
Walker, Clinton B.
Standards for evaluating criterion-referenced tests are presented. Twenty-one standards, grouped in three categories, are discussed. Category one is defined as measurement properties and is comprised of conceptual validity, including description of the domain, test item agreement with objectives, and item representativeness of the objectives; and…
2013-02-01
or funds authorized under Section 219(a) for projects costing no more than $4M. Research , Development, Test , and Evaluation (RDT&E) Appropriations...The RDT&E appropriation consists of the mission program budgets for all research , development, test and evaluation work performed by contractors...carry out an unspecified minor military construction project costing not more than $4,000,000. 9 f. Research , Development, Test , and Evaluation
2015-05-01
Evaluation Center of Excellence SUAS Small Unmanned Aircraft System SUT System under Test T&E Test and Evaluation TARDEC Tank Automotive Research...17 Distribution A: Distribution Unlimited 2 Background In the past decade, unmanned systems have significantly impacted warfare...environments at a speed and scale beyond manned capability. However, current unmanned systems operate with minimal autonomy. To meet warfighter needs and
1980-01-10
Experimentation (FDTE) 138 Corps Automation Requirements Baseline Identification Test (CARBIT) 138 Division Materiel Management Center (DMMC) 139 Concept...Evaluation Programs (CEP) 139 Test Design and Evaluation 140 Test and Evaluation Milestone Management System (TEMMS) 140 Manpower Analysis/Force...System (CS3) Maintenance Reporting and Management (MRM) 153 DA - Standard Port System (DASPS) 154 DA - Standard Port System - Enhancement (DASPS-E) 155 DA
AGARD Flight Test Techniques Series. Volume 8. Flight Testing under Extreme Environmental Conditions
1988-01-01
gravity control system operation. The overall objective of fuel system tests is to determine whether the system functions properly at all conditions both... gravity . 3.3.4 Hydraulic System The functional adequacy of the hydraulic system should be evaluated by monitoring operating system temperatures and...mechanical or gravity function of the crew ladder should be evaluated. The ladder should be exposed to freasing rain and icing to evaluate the non
2016-07-01
DOER) program, diesel fuel additives were tested to evaluate their potential for reducing diesel fuel consumption and cost. Four fuel additives were...tested to evaluate their potential for reducing diesel fuel consumption and cost: • An ethanol injection system • Envirofuels Diesel Fuel Catalyst...reduction in select operation conditions, only the ethanol injection system consistently showed potential to reduce diesel fuel consumption , which may be
Electrochemical Test Method for Evaluating Long-Term Propellant-Material Compatibility
1978-12-01
matrix of test conditions is illustrated in Fig. 13. A statistically designed test matrix (Graeco-Latin Cube) could not be used because of passivation...ears simulated time results in a findl decomposition level of 0.753 mg/cm The data was examined using statistical techniqves to evaluate the relative...metals. The compatibility of all nine metals was evaluated in hydrazine containing water and chloride. The results of the statistical analy(is
NASA Astrophysics Data System (ADS)
Pizzini, Edward L.; Treagust, David F.; Cody, John
The purpose of this study was to determine whether or not formative evaluation could facilitate goal attainment in a biochemistry course and produce desired learning outcomes consistently by altering course materials and/or instruction. Formative evaluation procedures included the administration of the Inorganic-Organic-Biological Chemistry Test Form 1974 and the Methods and Procedures of Science test to course participants over three consecutive years. A one group pretest-post-test design was used. The statistical analysis involved the use of the Wilcoxon matched-pairs signed-ranks test. The study involved 64 participants. The findings indicate that the use of formative evaluation can be effective in producing desired learning outcomes to facilitate goal attainment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, Darren M.
Sandia National Laboratories has tested and evaluated Geotech Smart24 data acquisition system with active Fortezza crypto card data signing and authentication. The test results included in this report were in response to static and tonal-dynamic input signals. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters; others were designed by Sandia specifically for infrasound application evaluation and for supplementary criteria not addressed in the IEEE standards. The objective of this work was to evaluate the overall technical performance of the Geotech Smart24 digitizer with a Fortezza PCMCIA cryptomore » card actively implementing the signing of data packets. The results of this evaluation were compared to relevant specifications provided within manufacturer's documentation notes. The tests performed were chosen to demonstrate different performance aspects of the digitizer under test. The performance aspects tested include determining noise floor, least significant bit (LSB), dynamic range, cross-talk, relative channel-to-channel timing, time-tag accuracy, analog bandwidth and calibrator performance.« less
NASA Technical Reports Server (NTRS)
Ray, Ronald J.
1994-01-01
New flight test maneuvers and analysis techniques for evaluating the dynamic response of in-flight thrust models during throttle transients have been developed and validated. The approach is based on the aircraft and engine performance relationship between thrust and drag. Two flight test maneuvers, a throttle step and a throttle frequency sweep, were developed and used in the study. Graphical analysis techniques, including a frequency domain analysis method, were also developed and evaluated. They provide quantitative and qualitative results. Four thrust calculation methods were used to demonstrate and validate the test technique. Flight test applications on two high-performance aircraft confirmed the test methods as valid and accurate. These maneuvers and analysis techniques were easy to implement and use. Flight test results indicate the analysis techniques can identify the combined effects of model error and instrumentation response limitations on the calculated thrust value. The methods developed in this report provide an accurate approach for evaluating, validating, or comparing thrust calculation methods for dynamic flight applications.
Roppola, Katri; Kuokkanen, Toivo; Rämö, Jaakko; Prokkola, Hanna; Heiska, Eeva
2007-01-01
The aim of this research was to study the suitability of a manometric respirometric test (OECD 301F) for the determination of biological oxygen demand (BOD) in domestic wastewater. This was done by comparing four different BOD tests (a manometric respirometric test, oxygen sensor determination, iodometric titration, and UV absorption measurement) and by evaluating the BOD7 value after a short-term measurement applying the manometric respirometric test. Measurements were done in three different laboratories. The respirometric test was performed well on municipal sewage, and the precision of results was good. There were minor deviations between BOD7 values as determined by the different methods, but the deviations were not essentially big enough to have a practical impact. Evaluation of the BOD7 value after two or three days' incubation by the respirometric method was shown to work well; average deviations between measured and evaluated values after three days' incubation were 5–18%. Hence, the manometric respirometric test proved to be a rapid and suitable tool for process control purposes. PMID:17671608
Flat panel display test and evaluation: procedures, standards, and facilities
NASA Astrophysics Data System (ADS)
Jackson, Timothy W.; Daniels, Reginald; Hopper, Darrel G.
1997-07-01
This paper addresses flat panel display test and evaluation via a discussion of procedures, standards and facilities. Procedures need to be carefully developed and documented to ensure that test accomplished in separate laboratories produce comparable results. The tests themselves must not be a source of inconsistency in test results when such comparisons are made in the course of procurements or new technology prototype evaluations. Standards are necessary to expedite the transition of the new display technologies into applications and to lower the costs of custom parts applied across disparate applications. The flat panel display industry is in the course of ascertaining and formulating such standards as they are of value to designers, manufacturers, marketers and users of civil and military products and equipment. Additionally, in order to inform the DoD and industry, the test and evaluation facilities of the Air Force Research Laboratory Displays Branch are described. These facilities are available to support procurements involving flat panel displays and to examine new technology prototypes. Finally, other government display testing facilities within the Navy and the Army are described.
EVALUATION OF A NEW MEAN SCALED AND MOMENT ADJUSTED TEST STATISTIC FOR SEM.
Tong, Xiaoxiao; Bentler, Peter M
2013-01-01
Recently a new mean scaled and skewness adjusted test statistic was developed for evaluating structural equation models in small samples and with potentially nonnormal data, but this statistic has received only limited evaluation. The performance of this statistic is compared to normal theory maximum likelihood and two well-known robust test statistics. A modification to the Satorra-Bentler scaled statistic is developed for the condition that sample size is smaller than degrees of freedom. The behavior of the four test statistics is evaluated with a Monte Carlo confirmatory factor analysis study that varies seven sample sizes and three distributional conditions obtained using Headrick's fifth-order transformation to nonnormality. The new statistic performs badly in most conditions except under the normal distribution. The goodness-of-fit χ(2) test based on maximum-likelihood estimation performed well under normal distributions as well as under a condition of asymptotic robustness. The Satorra-Bentler scaled test statistic performed best overall, while the mean scaled and variance adjusted test statistic outperformed the others at small and moderate sample sizes under certain distributional conditions.
Simonsen, Daniel; Nielsen, Ida F; Spaich, Erika G; Andersen, Ole K
2017-05-02
The present paper describes the design and evaluation of an automated version of the Modified Jebsen Test of Hand Function (MJT) based on the Microsoft Kinect sensor. The MJT was administered twice to 11 chronic stroke subjects with varying degrees of hand function deficits. The test times of the MJT were evaluated manually by a therapist using a stopwatch, and automatically using the Microsoft Kinect sensor. The ground truth times were assessed based on inspection of the video-recordings. The agreement between the methods was evaluated along with the test-retest performance. The results from Bland-Altman analysis showed better agreement between the ground truth times and the automatic MJT time evaluations compared to the agreement between the ground truth times and the times estimated by the therapist. The results from the test-retest performance showed that the subjects significantly improved their performance in several subtests of the MJT, indicating a practice effect. The results from the test showed that the Kinect can be used for automating the MJT.
The philosophy of benchmark testing a standards-based picture archiving and communications system.
Richardson, N E; Thomas, J A; Lyche, D K; Romlein, J; Norton, G S; Dolecek, Q E
1999-05-01
The Department of Defense issued its requirements for a Digital Imaging Network-Picture Archiving and Communications System (DIN-PACS) in a Request for Proposals (RFP) to industry in January 1997, with subsequent contracts being awarded in November 1997 to the Agfa Division of Bayer and IBM Global Government Industry. The Government's technical evaluation process consisted of evaluating a written technical proposal as well as conducting a benchmark test of each proposed system at the vendor's test facility. The purpose of benchmark testing was to evaluate the performance of the fully integrated system in a simulated operational environment. The benchmark test procedures and test equipment were developed through a joint effort between the Government, academic institutions, and private consultants. Herein the authors discuss the resources required and the methods used to benchmark test a standards-based PACS.
Hood, Julia E; MacKellar, Duncan; Spaulding, Anne; Nelson, Rob; Mosiakgabo, Boingotlo; Sikwa, Bangwato; Puso, Innocentia; Raats, Jan; Loeto, Peter; Alwano, Mary Grace; Monyatsi, Blessed
2012-10-01
Using data from Botswana's largest HIV testing and counseling (HTC) provider, Tebelopele, we evaluate populations served and gender-specific correlates of testing HIV-positive among clients of two programs: standalone centers and outreach testing. Client records from January to June 2007 (n = 47,890) were evaluated by HTC program and gender. Bivariate and multivariate analyses were performed to identify demographic, testing, and risk-behavior variables associated with testing HIV-positive. Compared to outreach testing, standalone centers served proportionally more clients who were young, well-educated, unmarried, and HIV-infected; outreach testing reached an older, less-educated population. Age, educational attainment, marital status, couples testing, testing because of illness or discordant relationship, and nonuse of condoms (among young clients only) were consistently associated with testing HIV-positive, by HTC program and gender. Our evaluation suggests that Tebelopele standalone and outreach HTC programs serve different populations, and identifies strategies to reduce HIV infection risk and to improve uptake of HTC by HIV-infected, undiagnosed Batswana.
Mizukami, Takuo; Momose, Haruka; Kuramitsu, Madoka; Takizawa, Kazuya; Araki, Kumiko; Furuhata, Keiko; Ishii, Ken J.; Hamaguchi, Isao; Yamaguchi, Kazunari
2014-01-01
Vaccines are beneficial and universal tools to prevent infectious disease. Thus, safety of vaccines is strictly evaluated in the preclinical phase of trials and every vaccine batch must be tested by the National Control Laboratories according to the guidelines published by each country. Despite many vaccine production platforms and methods, animal testing for safety evaluation is unchanged thus far. We recently developed a systems biological approach to vaccine safety evaluation where identification of specific biomarkers in a rat pre-clinical study evaluated the safety of vaccines for pandemic H5N1 influenza including Irf7, Lgals9, Lgalsbp3, Cxcl11, Timp1, Tap2, Psmb9, Psme1, Tapbp, C2, Csf1, Mx2, Zbp1, Ifrd1, Trafd1, Cxcl9, β2m, Npc1, Ngfr and Ifi47. The current study evaluated whether these 20 biomarkers could evaluate the safety, batch-to-batch and manufacturer-to-manufacturer consistency of seasonal trivalent influenza vaccine using a multiplex gene detection system. When we evaluated the influenza HA vaccine (HAv) from four different manufactures, the biomarker analysis correlated to findings from conventional animal use tests, such as abnormal toxicity test. In addition, sensitivity of toxicity detection and differences in HAvs were higher and more accurate than with conventional methods. Despite a slight decrease in body weight caused by HAv from manufacturer B that was not statistically significant, our results suggest that HAv from manufacturer B is significantly different than the other HAvs tested with regard to Lgals3bp, Tapbp, Lgals9, Irf7 and C2 gene expression in rat lungs. Using the biomarkers confirmed in this study, we predicted batch-to-batch consistency and safety of influenza vaccines within 2 days compared with the conventional safety test, which takes longer. These biomarkers will facilitate the future development of new influenza vaccines and provide an opportunity to develop in vitro methods of evaluating batch-to-batch consistency and vaccine safety as an alternative to animal testing. PMID:25010690
Electronic evaluation for freshmen nursing students: Advantages and disadvantages.
González, Fidelina; Ramírez, Julia
2006-01-01
An electronic evaluation was applied to freshmen nursing students who are taking Biology and Nursing Introduction. Questions and alternatives were randomly ordered. Evaluation took place simultaneously for all the students. Students preferred multiple choice questions with no more than two lines of headings and requested about three minutes for test timing. Test scores from electronic evaluation were higher than the ones obtained with written evaluation. This result implies that information technology can be used for evaluating large group of students.
Feretti, Donatella; Pedrazzani, Roberta; Ceretti, Elisabetta; Zerbini, Ilaria; Gozio, Eleonora; Belotti, Caterina; Alias, Carlotta; Donato, Francesco; Gelatti, Umberto
2009-01-01
The aim of this study was to evaluate the mutagenicity of several traditional detergents and that of newer more biodegradable detergents, by using a bacterial test (Ames test), a plant cell test (Allium cepa micronuclei test) and a human leucocyte test (Comet test). All tests were conducted using a wide range of doses (1-2000 mg/l). None of the examined detergents induced mutations in S.typhimurium. One traditional detergent showed a genotoxic effect with the A. cepa test, while all newer detergents and one traditional detergent were shown by the Comet test to be capable of inducing DNA damage.
Project W-314 specific test and evaluation plan for transfer line SN-633 (241-AX-B to 241-AY-02A)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hays, W.H.
1998-03-20
The purpose of this Specific Test and Evaluation Plan (STEP) is to provide a detailed written plan for the systematic testing of modifications made by the addition of the SN-633 transfer line by the W-314 Project. The STEP develops the outline for test procedures that verify the system`s performance to the established Project design criteria. The STEP is a lower tier document based on the W-314 Test and Evaluation Plan (TEP). This STEP encompasses all testing activities required to demonstrate compliance to the project design criteria as it relates to the addition of transfer line SN-633. The Project Design Specificationsmore » (PDS) identify the specific testing activities required for the Project. Testing includes Validations and Verifications (e.g., Commercial Grade Item Dedication activities), Factory Acceptance Tests (FATs), installation tests and inspections, Construction Acceptance Tests (CATs), Acceptance Test Procedures (ATPs), Pre-Operational Test Procedures (POTPs), and Operational Test Procedures (OTPs). It should be noted that POTPs are not required for testing of the transfer line addition. The STEP will be utilized in conjunction with the TEP for verification and validation.« less
Analysis of key technologies for virtual instruments metrology
NASA Astrophysics Data System (ADS)
Liu, Guixiong; Xu, Qingui; Gao, Furong; Guan, Qiuju; Fang, Qiang
2008-12-01
Virtual instruments (VIs) require metrological verification when applied as measuring instruments. Owing to the software-centered architecture, metrological evaluation of VIs includes two aspects: measurement functions and software characteristics. Complexity of software imposes difficulties on metrological testing of VIs. Key approaches and technologies for metrology evaluation of virtual instruments are investigated and analyzed in this paper. The principal issue is evaluation of measurement uncertainty. The nature and regularity of measurement uncertainty caused by software and algorithms can be evaluated by modeling, simulation, analysis, testing and statistics with support of powerful computing capability of PC. Another concern is evaluation of software features like correctness, reliability, stability, security and real-time of VIs. Technologies from software engineering, software testing and computer security domain can be used for these purposes. For example, a variety of black-box testing, white-box testing and modeling approaches can be used to evaluate the reliability of modules, components, applications and the whole VI software. The security of a VI can be assessed by methods like vulnerability scanning and penetration analysis. In order to facilitate metrology institutions to perform metrological verification of VIs efficiently, an automatic metrological tool for the above validation is essential. Based on technologies of numerical simulation, software testing and system benchmarking, a framework for the automatic tool is proposed in this paper. Investigation on implementation of existing automatic tools that perform calculation of measurement uncertainty, software testing and security assessment demonstrates the feasibility of the automatic framework advanced.
ERIC Educational Resources Information Center
Haeusser, Christiane
1978-01-01
The test described here is a particular type of diagnostic test; it is part of a series of tests designed to explore systematically areas of potential lexical difficulty in the English language for French-speaking students of English. The lexical units are considered under their formal, morphological, syntactic and semantic aspects. The test has…
Brodic, Darko; Milivojevic, Dragan R.; Milivojevic, Zoran N.
2011-01-01
The paper introduces a testing framework for the evaluation and validation of text line segmentation algorithms. Text line segmentation represents the key action for correct optical character recognition. Many of the tests for the evaluation of text line segmentation algorithms deal with text databases as reference templates. Because of the mismatch, the reliable testing framework is required. Hence, a new approach to a comprehensive experimental framework for the evaluation of text line segmentation algorithms is proposed. It consists of synthetic multi-like text samples and real handwritten text as well. Although the tests are mutually independent, the results are cross-linked. The proposed method can be used for different types of scripts and languages. Furthermore, two different procedures for the evaluation of algorithm efficiency based on the obtained error type classification are proposed. The first is based on the segmentation line error description, while the second one incorporates well-known signal detection theory. Each of them has different capabilities and convenience, but they can be used as supplements to make the evaluation process efficient. Overall the proposed procedure based on the segmentation line error description has some advantages, characterized by five measures that describe measurement procedures. PMID:22164106
Brodic, Darko; Milivojevic, Dragan R; Milivojevic, Zoran N
2011-01-01
The paper introduces a testing framework for the evaluation and validation of text line segmentation algorithms. Text line segmentation represents the key action for correct optical character recognition. Many of the tests for the evaluation of text line segmentation algorithms deal with text databases as reference templates. Because of the mismatch, the reliable testing framework is required. Hence, a new approach to a comprehensive experimental framework for the evaluation of text line segmentation algorithms is proposed. It consists of synthetic multi-like text samples and real handwritten text as well. Although the tests are mutually independent, the results are cross-linked. The proposed method can be used for different types of scripts and languages. Furthermore, two different procedures for the evaluation of algorithm efficiency based on the obtained error type classification are proposed. The first is based on the segmentation line error description, while the second one incorporates well-known signal detection theory. Each of them has different capabilities and convenience, but they can be used as supplements to make the evaluation process efficient. Overall the proposed procedure based on the segmentation line error description has some advantages, characterized by five measures that describe measurement procedures.
Development of Tasks and Evaluation of a Prototype Forceps for NOTES
Addis, Matthew; Aguirre, Milton; Haluck, Randy; Matthew, Abraham; Pauli, Eric; Gopal, Jegan
2012-01-01
Background and Objectives: Few standardized testing procedures exist for instruments intended for Natural Orifice Translumenal Endoscopic Surgery. These testing procedures are critical for evaluating surgical skills and surgical instruments to ensure sufficient quality. This need is widely recognized by endoscopic surgeons as a major hurdle for the advancement of Natural Orifice Translumenal Endoscopic Surgery. Methods: Beginning with tasks currently used to evaluate laparoscopic surgeons and instruments, new tasks were designed to evaluate endoscopic surgical forceps instruments. Results: Six tasks have been developed from existing tasks, adapted and modified for use with endoscopic instruments, or newly designed to test additional features of endoscopic forceps. The new tasks include the Fuzzy Ball Task, Cup Drop Task, Ring Around Task, Material Pull Task, Simulated Biopsy Task, and the Force Gauge Task. These tasks were then used to evaluate the performance of a new forceps instrument designed at Pennsylvania State University. Conclusions: The need for testing procedures for the advancement of Natural Orifice Translumenal Endoscopic Surgery has been addressed in this work. The developed tasks form a basis for not only testing new forceps instruments, but also for evaluating individual performance of surgical candidates with endoscopic forceps instruments. PMID:22906337
Quantitative methods in assessment of neurologic function.
Potvin, A R; Tourtellotte, W W; Syndulko, K; Potvin, J
1981-01-01
Traditionally, neurologists have emphasized qualitative techniques for assessing results of clinical trials. However, in recent years qualitative evaluations have been increasingly augmented by quantitative tests for measuring neurologic functions pertaining to mental state, strength, steadiness, reactions, speed, coordination, sensation, fatigue, gait, station, and simulated activities of daily living. Quantitative tests have long been used by psychologists for evaluating asymptomatic function, assessing human information processing, and predicting proficiency in skilled tasks; however, their methodology has never been directly assessed for validity in a clinical environment. In this report, relevant contributions from the literature on asymptomatic human performance and that on clinical quantitative neurologic function are reviewed and assessed. While emphasis is focused on tests appropriate for evaluating clinical neurologic trials, evaluations of tests for reproducibility, reliability, validity, and examiner training procedures, and for effects of motivation, learning, handedness, age, and sex are also reported and interpreted. Examples of statistical strategies for data analysis, scoring systems, data reduction methods, and data display concepts are presented. Although investigative work still remains to be done, it appears that carefully selected and evaluated tests of sensory and motor function should be an essential factor for evaluating clinical trials in an objective manner.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rembold, Randy Kai; Hart, Darren M.
Sandia National Laboratories has tested and evaluated Geotech SMART24BH borehole data acquisition system with active Fortezza crypto card data signing and authentication. The test results included in this report were in response to static and tonal-dynamic input signals. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters; others were designed by Sandia specifically for infrasound application evaluation and for supplementary criteria not addressed in the IEEE standards. The objective of this work was to evaluate the overall technical performance of two Geotech SMART24BH digitizers with a Fortezza PCMCIAmore » crypto card actively implementing the signing of data packets. The results of this evaluation were compared to relevant specifications provided within manufacturer's documentation notes. The tests performed were chosen to demonstrate different performance aspects of the digitizer under test. The performance aspects tested include determining noise floor, least significant bit (LSB), dynamic range, cross-talk, relative channel-to-channel timing, time-tag accuracy/statistics/drift, analog bandwidth.« less
NASA Technical Reports Server (NTRS)
Rummel, W. D.; Rathke, R. A.; Todd, P. H., Jr.; Mullen, S. J.
1975-01-01
Liquid penetrant, ultrasonic, eddy current and X-radiographic techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens in integrally stiffened panel, and weld panel configurations. Fatigue cracks in integrally stiffened panels, lack-of-fusion in weld panels, and fatigue cracks in weld panels were the flaw types used for evaluation. A 2319 aluminum alloy weld filler rod was used for all welding to produce the test specimens. Forty seven integrally stiffened panels containing a total of 146 fatigue cracks, ninety three lack-of-penetration (LOP) specimens containing a total of 239 LOP flaws, and one-hundred seventeen welded specimens containing a total of 293 fatigue cracks were evaluated. Nondestructive test detection reliability enhancement was evaluated during separate inspection sequences in the specimens in the 'as-machined or as-welded', post etched and post proof loaded conditions. Results of the nondestructive test evaluations were compared to the actual flaw size obtained by measurement of the fracture specimens after completing all inspection sequences. Inspection data were then analyzed to provide a statistical basis for determining the flaw detection reliability.
ERIC Educational Resources Information Center
Lam, Tony C. N.; And Others
This report describes an extensive field test of the Bilingual Education Evaluation System (BEES) used to evaluate local level bilingual education projects. Because such projects will usually not be able to implement a traditional true or quasi-experimental design, BEES employs a "gap-reduction" evaluation design that is easily…
Evaluation of "e-rater"® for the "Praxis I"®Writing Test. Research Report. ETS RR-15-03
ERIC Educational Resources Information Center
Ramineni, Chaitanya; Trapani, Catherine S.; Williamson, David M.
2015-01-01
Automated scoring models were trained and evaluated for the essay task in the "Praxis I"® writing test. Prompt-specific and generic "e-rater"® scoring models were built, and evaluation statistics, such as quadratic weighted kappa, Pearson correlation, and standardized differences in mean scores, were examined to evaluate the…
Report on Pilot Test Of Impact and In-Depth Measures. Child and Family Mental Health Project.
ERIC Educational Resources Information Center
Condry, Sandra; Hayes, William A.
This document reports the pilot test of the two components of the Child and Family Mental Health (CFMH) Evaluation Project -- the impact evaluation component and the in-depth evaluation component. (The impact evaluation is designed to determine the effects of the two primary prevention models of service and activities on the CFMH Head Start…
2010-07-01
applicants and is pursing further research on the WPA. An operational test and evaluation ( IOT &E) has been initiated to evaluate the new screen...initial operational test and evaluation ( IOT &E) starting in fall 2009. vii EXPANDED ENLISTMENT ELIGIBILITY METRICS (EEEM): RECOMMENDATIONS ON A NON...Evaluation of a Performance Screen for IOT &E ..................................... 49 Approach
A framework provided an outline toward the proper evaluation of potential screening strategies.
Adriaensen, Wim J; Matheï, Cathy; Buntinx, Frank J; Arbyn, Marc
2013-06-01
Screening tests are often introduced into clinical practice without proper evaluation, despite the increasing awareness that screening is a double-edged sword that can lead to either net benefits or harms. Our objective was to develop a comprehensive framework for the evaluation of new screening strategies. Elaborating on the existing concepts proposed by experts, a stepwise framework is proposed to evaluate whether a potential screening test can be introduced as a screening strategy into clinical practice. The principle of screening strategy evaluation is illustrated for cervical cancer, which is a template for screening because of the existence of an easily detectable and treatable precursor lesion. The evaluation procedure consists of six consecutive steps. In steps 1-4, the technical accuracy, place of the test in the screening pathway, diagnostic accuracy, and longitudinal sensitivity and specificity of the screening test are assessed. In steps 5 and 6, the impact of the screening strategy on the patient and population levels, respectively, is evaluated. The framework incorporates a harm and benefit trade-off and cost-effectiveness analysis. Our framework provides an outline toward the proper evaluation of potential screening strategies before considering implementation. Copyright © 2013 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Van Vonno, N. W.
1972-01-01
Development of an alternate approach to the conventional methods of reliability assurance for large-scale integrated circuits. The product treated is a large-scale T squared L array designed for space applications. The concept used is that of qualification of product by evaluation of the basic processing used in fabricating the product, providing an insight into its potential reliability. Test vehicles are described which enable evaluation of device characteristics, surface condition, and various parameters of the two-level metallization system used. Evaluation of these test vehicles is performed on a lot qualification basis, with the lot consisting of one wafer. Assembled test vehicles are evaluated by high temperature stress at 300 C for short time durations. Stressing at these temperatures provides a rapid method of evaluation and permits a go/no go decision to be made on the wafer lot in a timely fashion.
Evaluation of pediatric upper extremity peripheral nerve injuries.
Ho, Emily S
2015-01-01
The evaluation of motor and sensory function of the upper extremity after a peripheral nerve injury is critical to diagnose the location and extent of nerve injury as well as document functional recovery in children. The purpose of this paper is to describe an approach to the evaluation of the pediatric upper extremity peripheral nerve injuries through a critical review of currently used tests of sensory and motor function. Outcome studies on pediatric upper extremity peripheral nerve injuries in the Medline database were reviewed. The evaluation of the outcome in children less than 10 years of age with an upper extremity peripheral nerve injury includes careful observation of preferred prehension patterns, examination of muscle atrophy and sudomotor function, provocative tests, manual muscle testing and tests of sensory threshold and tactile gnosis. The evaluation of outcome in children with upper extremity peripheral nerve injuries warrants a unique approach. Copyright © 2015 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.
[Biological evaluation within a risk management process].
Zhuang, Fei; Ding, Biao
2007-07-01
Bio-evaluation within the medical device quality/risk management system is a risk analyzing and assessing process. On the basis of data from characterization of materials, scientific literatures, application history, bio-toxicology testing and so on, weighing the benefit and the risk, bio-evaluation does a conclusion to "take" or "quit" the product design. There is no "zero risk" though "no toxicity" always is the most desirable conclusion in a testing report. The application history data is the most comprehensive among the information available, since no testing system can "clone" the human body. In addition, the capital cost has to be taken into account when bringing the sophisticated testing technologies into the evaluating system. Investigating the #G95-1 of FDA CDRH and the changes of ISO 10993-1, the trend to integrate bio-evaluation into a quality/risk management process can be figured out.
A 100-Year Review: Sensory analysis of milk.
Schiano, A N; Harwood, W S; Drake, M A
2017-12-01
Evaluation of the sensory characteristics of food products has been, and will continue to be, the ultimate method for evaluating product quality. Sensory quality is a parameter that can be evaluated only by humans and consists of a series of tests or tools that can be applied objectively or subjectively within the constructs of carefully selected testing procedures and parameters. Depending on the chosen test, evaluators are able to probe areas of interest that are intrinsic product attributes (e.g., flavor profiles and off-flavors) as well as extrinsic measures (e.g., market penetration and consumer perception). This review outlines the literature pertaining to relevant testing procedures and studies of the history of sensory analysis of fluid milk. In addition, evaluation methods outside of traditional sensory techniques and future outlooks on the subject of sensory analysis of fluid milk are explored and presented. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Lynch, Mervin D.; Chaves, John
Items from Peirs-Harris and Coopersmith self-concept tests were evaluated against independent measures on three self-constructs, idealized, empathic, and worth. Construct measurements were obtained with the semantic differential and D statistic. Ratings were obtained from 381 children, grades 4-6. For each test, item ratings and construct measures…
The Use of Different Achievement Tests in the ESEA Title I Evaluation System.
ERIC Educational Resources Information Center
Tallmadge, G. Kasten; Horst, Donald P.
In this discussion of the use of achievement tests in evaluating Title I programs, matching content between test and curriculum is the main theme. The point is made that unless a test measures what is taught, it cannot be sensitive to whatever gains the instruction produces. Thus, if different instructional treatments have different objectives, it…
50 CFR 622.41 - Species specific limitations.
Code of Federal Regulations, 2010 CFR
2010-10-01
...-certification. The pre-certification phase allows a person to test and evaluate a new BRD design for up to 60... authorized by the RA to participate in the pre-certification testing phase or to test a BRD in the EEZ for...-certification phase allows a person to test and evaluate a new BRD design for up to 60 days without being...
50 CFR 622.41 - Species specific limitations.
Code of Federal Regulations, 2011 CFR
2011-10-01
...-certification. The pre-certification phase allows a person to test and evaluate a new BRD design for up to 60... authorized by the RA to participate in the pre-certification testing phase or to test a BRD in the EEZ for...-certification phase allows a person to test and evaluate a new BRD design for up to 60 days without being...
ERIC Educational Resources Information Center
Golovachyova, Viktoriya N.; Menlibekova, Gulbakhyt Zh.; Abayeva, Nella F.; Ten, Tatyana L.; Kogaya, Galina D.
2016-01-01
Using computer-based monitoring systems that rely on tests could be the most effective way of knowledge evaluation. The problem of objective knowledge assessment by means of testing takes on a new dimension in the context of new paradigms in education. The analysis of the existing test methods enabled us to conclude that tests with selected…
Ultrasonic test of resistance spot welds based on wavelet package analysis.
Liu, Jing; Xu, Guocheng; Gu, Xiaopeng; Zhou, Guanghao
2015-02-01
In this paper, ultrasonic test of spot welds for stainless steel sheets has been studied. It is indicated that traditional ultrasonic signal analysis in either time domain or frequency domain remains inadequate to evaluate the nugget diameter of spot welds. However, the method based on wavelet package analysis in time-frequency domain can easily distinguish the nugget from the corona bond by extracting high-frequency signals in different positions of spot welds, thereby quantitatively evaluating the nugget diameter. The results of ultrasonic test fit the actual measured value well. Mean value of normal distribution of error statistics is 0.00187, and the standard deviation is 0.1392. Furthermore, the quality of spot welds was evaluated, and it is showed ultrasonic nondestructive test based on wavelet packet analysis can be used to evaluate the quality of spot welds, and it is more reliable than single tensile destructive test. Copyright © 2014 Elsevier B.V. All rights reserved.
Battery testing at Argonne National Laboratory
NASA Astrophysics Data System (ADS)
Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.
1993-03-01
Argonne National Laboratory's Analysis & Diagnostic Laboratory (ADL) tests advanced batteries under simulated electric and hybrid vehicle operating conditions. The ADL facilities also include a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The battery evaluations and post-test examinations help identify factors that limit system performance and life and the most-promising R&D approaches for overcoming these limitations. Since 1991, performance characterizations and/or life evaluations have been conducted on eight battery technologies: Na/S, Li/S, Zn/Br, Ni/MH, Ni/Zn, Ni/Cd, Ni/Fe, and lead-acid. These evaluations were performed for the Department of Energy's. Office of Transportation Technologies, Electric and Hybrid Propulsion Division (DOE/OTT/EHP), and Electric Power Research Institute (EPRI) Transportation Program. The results obtained are discussed.
Effectiveness evaluation of several cattle anthelmintics via the fecal egg count reduction test.
Yazwinski, T A; Tucker, C A; Hornsby, J A; Powell, J G; Reynolds, J L; Johnson, Z B; Lindsey, W; Silver, T K
2009-07-01
Utilizing groups of cograzed, naturally infected beef-type heifers, three fecal egg count reduction tests were conducted in the later months of 2007 at the University of Arkansas. Each test was 28 days in length consisting of individual animal fecal nematode egg counts and coprocultures. Both original and generic ivermectin injectable formulations were used in two of the tests at 0.2 mg/kg BW, with FECR percentages never exceeding 90% in either test. Oral fenbendazole was evaluated at 5 and 10 mg/kg BW, with FECR%'s exceeding 90% on all occasions, but with a precipitous drop when recently treated animals were treated at the lower dose. Evaluated in one test, injectable moxidectin given at 0.2 mg/kg BW resulted in egg count reductions of 96-92% (days 7 to 28). Also evaluated in one test, albendazole delivered orally at 10 mg/kg BW was 98% and 97% effective at 17 and 28 days post-treatment. For all tests, coprocultures conducted post-treatment contained only Cooperia spp. larvae (benzimidazole use), relatively unmodified percentages of Cooperia spp. and Haemonchus spp. larvae (ivermectin use), and primarily Cooperia spp. larvae with a small percentage of Haemonchus spp. larvae (moxidectin use).
PKI solar thermal plant evaluation at Capitol Concrete Products, Topeka, Kansas
NASA Astrophysics Data System (ADS)
Hauger, J. S.; Borton, D. N.
1982-07-01
A system feasibility test to determine the technical and operational feasibility of using a solar collector to provide industrial process heat is discussed. The test is of a solar collector system in an industrial test bed plant at Capitol Concrete Products in Topeka, Kansas, with an experiment control at Sandia National Laboratories, Albuquerque. Plant evaluation will occur during a year-long period of industrial utilization. It will include performance testing, operability testing, and system failure analysis. Performance data will be recorded by a data acquisition system. User, community, and environmental inputs will be recorded in logs, journals, and files. Plant installation, start-up, and evaluation, are anticipated for late November, 1981.
PKI solar thermal plant evaluation at Capitol Concrete Products, Topeka, Kansas
NASA Technical Reports Server (NTRS)
Hauger, J. S.; Borton, D. N.
1982-01-01
A system feasibility test to determine the technical and operational feasibility of using a solar collector to provide industrial process heat is discussed. The test is of a solar collector system in an industrial test bed plant at Capitol Concrete Products in Topeka, Kansas, with an experiment control at Sandia National Laboratories, Albuquerque. Plant evaluation will occur during a year-long period of industrial utilization. It will include performance testing, operability testing, and system failure analysis. Performance data will be recorded by a data acquisition system. User, community, and environmental inputs will be recorded in logs, journals, and files. Plant installation, start-up, and evaluation, are anticipated for late November, 1981.
A simple test for thermomechanical evaluation of ceramic fibers
NASA Technical Reports Server (NTRS)
Morscher, Gregory N.; Dicarlo, James A.
1991-01-01
A simple bend stress relaxation (BSR) test was developed to measure the creep related properties of ceramic fibers and whiskers. The test was applied to a variety of commercial and developmental Si based fibers to demonstrate capabilities and to evaluate the relative creep resistance of the fibers at 1200 to 1400 C. The implications of these results and the advantages of the BSR test over typical tensile creep tests are discussed.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-17
... for the Evaluation of Alternative Toxicological Methods (NICEATM); Availability of Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM) Test Method Evaluation Reports: In Vitro Ocular Safety Testing Methods and Strategies, and Routine Use of Topical Anesthetics, Systemic...
Development of a mechanical rocker test procedure for ice melting capacity evaluation.
DOT National Transportation Integrated Search
2014-06-01
During Phase 2 of the NDOR deicing chemicals performance evaluation project (No. SPR-P1(10) P328), a : simple and economical test using a martini shaker to evaluate ice melting capacity of liquid deicers showed : good potential to become a standardiz...
Response of crapemyrtle varieties to Cercospora leaf spot, 2015
USDA-ARS?s Scientific Manuscript database
Crapemyrtle varieties, Lagerstroemia spp., were evaluated for Cercospora leaf spot in two field test evaluations, planted in either 2004 or 2011 at the Otis L. Floyd Nursery Research Center in McMinnville, TN. The experimental designs for both test evaluations were a randomized complete block design...
DOT National Transportation Integrated Search
2016-07-01
This report describes two research activities. One research study tested the effects of adding commercial : logos acknowledging sponsorship to Changeable Message Signs. A driving simulator study was conducted : using test signs with travel times and ...
The State of Retrieval System Evaluation.
ERIC Educational Resources Information Center
Salton, Gerald
1992-01-01
The current state of information retrieval (IR) evaluation is reviewed with criticisms directed at the available test collections and the research and evaluation methodologies used, including precision and recall rates for online searches and laboratory tests not including real users. Automatic text retrieval systems are also discussed. (32…
NASA Technical Reports Server (NTRS)
1971-01-01
The findings, conclusions, and recommendations relative to the investigations conducted to evaluate tests for classifying pyrotechnic materials and end items as to their hazard potential are presented. Information required to establish an applicable means of determining the potential hazards of pyrotechnics is described. Hazard evaluations are based on the peak overpressure or impulse resulting from the explosion as a function of distance from the source. Other hazard classification tests include dust ignition sensitivity, impact ignition sensitivity, spark ignition sensitivity, and differential thermal analysis.
Measures of fish behavior as indicators of sublethal toxicosis during standard toxicity tests
Little, E.E.; DeLonay, A.J.
1996-01-01
Behavioral functions essential for growth and survival can be dramatically altered by sublethal exposure to toxicants. Measures of these behavioral responses are effective in detecting adverse effects of sublethal contaminant exposure. Behavioral responses of fishes can be qualitatively and quantitatively evaluated during routine toxicity tests. At selected intervals of exposure, qualitative evaluations are accomplished through direct observations, whereas video recordings are used for quantitative evaluations. Standardized procedures for behavioral evaluation are readily applicable to different fish species and provide rapid, sensitive, and ecologically relevant assessments of sublethal exposure. The methods are readily applied to standardized test protocols.
Performance evaluation of two black nickel and two black chrome solar collectors
NASA Technical Reports Server (NTRS)
Losey, R.
1977-01-01
The test program was based on the evaluation of four unique solar collectors described below: (1) black nickel collector surface with a desiccant drying bed, (2) black nickel collector surface without a desiccant drying bed, (3) black chrome collector surface with a dessicant drying bed, and (4) black chrome collector surface without a desiccant drying bed. The test program included three distinct phases: Initial performance evaluation, natural environmental aging, and post-aging performance evaluation. Results of Phase III testing conclusively indicated a higher normalized efficiency for Black Chrome surfaces when compared to Black Nickel.
THE ROLE OF MOTOR ACTIVITY IN THE ASSESSMENT OF NEUROTOXICITY
Motor activity is a behavioral test that has been recommended as a component of testing batteries that evaluate the neurotoxic potential of chemicals. his brief commentary will address the role of this test in such evaluations. t is organized in accordance with the questions that...
Evaluation of Surface Infiltration Testing Procedures in Permeable Pavement Systems
The ASTM method (ASTM C1701) for measuring infiltration rate of in-place pervious concrete provides limited guidance on how to select testing locations, so research is needed to evaluate how testing sites should be selected and how results should be interpreted to assess surface ...
Test and Evaluation Master Plan (TEMP) for the Ports and Waterways Safety System (PAWSS) Project
DOT National Transportation Integrated Search
1997-01-01
This document outlines the Test Concept for the Ports and Waterways Safety System (PAWSS) Project. This Test and Evaluation Master Plan (TEMP) purpose is to reduce risk and ensure the PAWSS project meets all System Specification and Statement of Work...
DOT National Transportation Integrated Search
2004-07-01
The test wall was constructed to evaluate the behavior of MSE walls constructed with silty-clay soils through comparison between predicted and field measurements. The primary objectives of the construction of the LTRC reinforced test wall were to mon...
Diagnostic Testing and Interpretation of Tests for Autoimmunity
Castro, Christine; Gourley, Mark
2010-01-01
Laboratory testing is of great value when evaluating a patient with a suspected autoimmune disease. The results can confirm a diagnosis, estimate disease severity, aid in assessing prognosis and are useful to follow disease activity. Components of the laboratory exam include complete blood count with differential, comprehensive metabolic panel, inflammatory markers, autoantibodies, and flow cytometry. This chapter discusses these components and includes a discussion about organ-specific immunologic diseases where immunological laboratory testing is employed. Comprehensive laboratory evaluation of a suspected autoimmune illness in conjunction with a thorough clinical evaluation provides a better understanding of a patient's immunologic disease. PMID:20061009
1993-04-01
separation capability. o Demonstrate advanced KKVs in the 6-20 KG weight class. o Test planning for SRAM/LEAP and PATRIOT/LEAP integrated technology...packaging techniques to reduce satellite size, weight , power, and total system costs. Further development of these technologies are absolutely 4...1993 o Developed a master plan with a delivery schedule for each light- weight subassembly in the sensor integration payload. o Finalized a contract for
Commercially available molecular tests for human papillomaviruses (HPV): 2015 update.
Poljak, Mario; Kocjan, Boštjan J; Oštrbenk, Anja; Seme, Katja
2016-03-01
Commercial molecular tests for human papillomaviruses (HPV) are invaluable diagnostic tools in cervical carcinoma screening and management of women with cervical precancerous lesions as well as important research tools for epidemiological studies, vaccine development, and implementation and monitoring of vaccination programs. In this third inventory of commercial HPV tests, we identified 193 distinct commercial HPV tests and at least 127 test variants available on the market in 2015, which represents a 54% and 79% increase in the number of distinct HPV tests and variants, respectively, in comparison to our last inventory performed in 2012. Identified HPV tests were provisionally divided into eight main groups and several subgroups. Among the 193 commercial HPV tests, all but two target alpha-HPV types only. Although the number of commercial HPV tests with at least one published study in peer-reviewed literature has increased significantly in the last three years, several published performance evaluations are still not in line with agreed-upon standards in the HPV community. Manufacturers should invest greater effort into evaluating their products and publishing validation/evaluation results in peer-reviewed journals. To achieve this, more clinically oriented external quality-control panels and initiatives are required. For evaluating the analytical performance of the entire range of HPV tests currently on the market, more diverse and reliable external quality-control programs based on international standards for all important HPV types are indispensable. The performance of a wider range of HPV tests must be promptly evaluated on a variety of alternative clinical specimens. In addition, more complete HPV assays containing validated sample-extraction protocols and appropriate internal controls are urgently needed. Provision of a broader range of automated systems allowing large-scale HPV testing as well as the development of reliable, rapid, and affordable molecular point-of-care tests are priorities for the further improvement of HPV tests. Copyright © 2015 Elsevier B.V. All rights reserved.
Gauthier, Lauraine; Dortet, Laurent; Naas, Thierry
2017-01-01
Background There is an urgent need for accurate and rapid diagnostic tests to identify carbapenemase producing enterobacteria (CPE). Here, we have evaluated the Carbapenem Inactivation Method (CIM) test to detect CPEs from cultured colonies. Methods A total of 256 enterobacterial isolates were used to evaluate the performance of the CIM in comparison to Carba NP test and molecular detection used a reference method. Ninety three well-characterized isolates (including 29 non-CPE and 63 CPEs of worldwide origin) with decreased susceptibility to at least one carbapenem were used to (i) evaluate the efficacy of CIM test and (ii) to compare it to the Carba NP test. We also tested different carbapenems to determine the best substrate for this test. Finally, the CIM test was then evaluated prospectively against 164 isolates referred to the French National Reference Center (NRC) for Antimicrobial Resistance from may 2016 to july 2016. Results Based on the results of this retrospective study, sensitivity and specificity of the CIM and the Carba NP test were 92.1% and 100%, respectively. We demonstrated that the meropenem was the best substrate to perform the CIM test since sensitivity and specificity were 81.1% and 100% using ertapenem disk, and 100% and 65,6% using imipenem disk, and respectively. Taking in account the results of retrospective and prospective studies, CIM and Carba NP tests have similar sensitivity, specificity, positive predictive value and negative predictive values being 96.3%, 98.9%, 99.0% and 98.4% for the CIM test versus 96.9%, 100%, 100% and 100% for the Carba NP test. Conclusions Our results confirm that the CIM test may be a useful tool for the reliable confirmation of carbapenemase-activity in enterobacterial isolates, especially in clinical microbiological laboratories with limited resources, no trained personnel, and no specialized equipment. PMID:28158310
Shuttle payload minimum cost vibroacoustic tests
NASA Technical Reports Server (NTRS)
Stahle, C. V.; Gongloff, H. R.; Young, J. P.; Keegan, W. B.
1977-01-01
This paper is directed toward the development of the methodology needed to evaluate cost effective vibroacoustic test plans for Shuttle Spacelab payloads. Statistical decision theory is used to quantitatively evaluate seven alternate test plans by deriving optimum test levels and the expected cost for each multiple mission payload considered. The results indicate that minimum costs can vary by as much as $6 million for the various test plans. The lowest cost approach eliminates component testing and maintains flight vibration reliability by performing subassembly tests at a relatively high acoustic level. Test plans using system testing or combinations of component and assembly level testing are attractive alternatives. Component testing alone is shown not to be cost effective.
Evaluation and Management of Patch Test-Negative Patients With Generalized Dermatitis.
Spiker, Alison; Mowad, Christen M
Patients with generalized dermatitis are common in dermatology practices. Allergic contact dermatitis is often suspected, and patients frequently undergo patch testing. When the patch testing result is negative, further evaluation and management of these patients are challenging. The purpose of this study was to survey members of the American Contact Dermatitis Society regarding the evaluation and management of patch test-negative patients with generalized dermatitis. Generalized dermatitis was the most common term identified for patch test-negative patients with diffuse dermatitis. After having negative expanded patch testing results, most physicians proceeded with additional testing including skin biopsy, complete blood cell count with differential, and liver and renal function tests. The most commonly used systemic treatment is prednisone, followed by methotrexate. Narrow-band ultraviolet B (UVB) is the most commonly used light source. Antihistamines are frequently prescribed. Food allergy is not felt to be causative. This cohort of patients experiences significant impairment in quality of life, stress on personal relationships, and time off work. The management of patch test-negative patients with generalized dermatitis is challenging. This study provides insight into management of these complex patients. It also demonstrates practice gaps in the management of these patients, indicating a need for further studies to direct the evaluation and management of this patient population.
Exploring Operational Test and Evaluation of Unmanned Aircraft Systems: A Qualitative Case Study
NASA Astrophysics Data System (ADS)
Saliceti, Jose A.
The purpose of this qualitative case study was to explore and identify strategies that may potentially remedy operational test and evaluation procedures used to evaluate Unmanned Aircraft Systems (UAS) technology. The sample for analysis consisted of organizations testing and evaluating UASs (e.g., U.S. Air Force, U.S. Navy, U.S. Army, U.S. Marine Corps, U.S. Coast Guard, and Customs Border Protection). A purposeful sampling technique was used to select 15 subject matter experts in the field of operational test and evaluation of UASs. A questionnaire was provided to participants to construct a descriptive and robust research. Analysis of responses revealed themes related to each research question. Findings revealed operational testers utilized requirements documents to extrapolate measures for testing UAS technology and develop critical operational issues. The requirements documents were (a) developed without the contribution of stakeholders and operational testers, (b) developed with vague or unrealistic measures, and (c) developed without a systematic method to derive requirements from mission tasks. Four approaches are recommended to develop testable operational requirements and assist operational testers: (a) use a mission task analysis tool to derive requirements for mission essential tasks for the system, (b) exercise collaboration among stakeholders and testers to ensure testable operational requirements based on mission tasks, (c) ensure testable measures are used in requirements documents, and (d) create a repository list of critical operational issues by mission areas. The preparation of operational test and evaluation processes for UAS technology is not uniform across testers. The processes in place are not standardized, thus test plan preparation and reporting are different among participants. A standard method to prepare and report UAS technology should be used when preparing and reporting on UAS technology. Using a systematic process, such as mission-based test design, resonated among participants as an analytical method to link UAS mission tasks and measures of performance to the capabilities of the system under test when developing operational test plans. Further research should examine system engineering designs for system requirements traceability matrix of mission tasks and subtasks while using an analysis tool that adequately evaluates UASs with an acceptable level of confidence in the results.
In situ impulse test: an experimental and analytical evaluation of data interpretation procedures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1975-08-01
Special experimental field testing and analytical studies were undertaken at Fort Lawton in Seattle, Washington, to study ''close-in'' wave propagation and evaluate data interpretation procedures for a new in situ impulse test. This test was developed to determine the shear wave velocity and dynamic modulus of soils underlying potential nuclear power plant sites. The test is different from conventional geophysical testing in that the velocity variation with strain is determined for each test. In general, strains between 10/sup -1/ and 10/sup -3/ percent are achieved. The experimental field work consisted of performing special tests in a large test sand fillmore » to obtain detailed ''close-in'' data. Six recording transducers were placed at various points on the energy source, while approximately 37 different transducers were installed within the soil fill, all within 7 feet of the energy source. Velocity measurements were then taken simultaneously under controlled test conditions to study shear wave propagation phenomenology and help evaluate data interpretation procedures. Typical test data are presented along with detailed descriptions of the results.« less
Dental Electric Handengines: Test and Evaluation.
1985-04-01
ADRD5 066 A DENTAL ELECTRIC HANDENGINES: TEST AND EVALUATION(U) j/ij SCHOOL OF AEROSPACE MEDICINE BROOKS AFB TX C D FOSTER ET AL. APR 85 USAFSAM-TR... DENTAL ELECTRIC HANDENGINES o Test and Evaluation In -- I Cad D. Foster, Major, USAF, DC Paul M. Callison, Master Sergeant, USAF Gerald F. McKinley...AFSC) Brooks Air Force Base, TX 78235-5301 85 7 15 057 NOTICES This final report was submitted by personnel of the Dental Investigation Service
Graphical Tests for Power Comparison of Competing Designs.
Hofmann, H; Follett, L; Majumder, M; Cook, D
2012-12-01
Lineups have been established as tools for visual testing similar to standard statistical inference tests, allowing us to evaluate the validity of graphical findings in an objective manner. In simulation studies lineups have been shown as being efficient: the power of visual tests is comparable to classical tests while being much less stringent in terms of distributional assumptions made. This makes lineups versatile, yet powerful, tools in situations where conditions for regular statistical tests are not or cannot be met. In this paper we introduce lineups as a tool for evaluating the power of competing graphical designs. We highlight some of the theoretical properties and then show results from two studies evaluating competing designs: both studies are designed to go to the limits of our perceptual abilities to highlight differences between designs. We use both accuracy and speed of evaluation as measures of a successful design. The first study compares the choice of coordinate system: polar versus cartesian coordinates. The results show strong support in favor of cartesian coordinates in finding fast and accurate answers to spotting patterns. The second study is aimed at finding shift differences between distributions. Both studies are motivated by data problems that we have recently encountered, and explore using simulated data to evaluate the plot designs under controlled conditions. Amazon Mechanical Turk (MTurk) is used to conduct the studies. The lineups provide an effective mechanism for objectively evaluating plot designs.
NASA Technical Reports Server (NTRS)
Kaufmann, David N.; Ncnally, B. David
1995-01-01
Test flights were conducted to evaluate the capability of Differential Global Positioning System (DGPS) to provide the accuracy and integrity required for International Civil Aviation Organization (ICAO) Category (CAT) 3 precision approach and landings. These test flights were part of a Federal Aviation Administration (FAA) program to evaluate the technical feasibility of using DGPS based technology for CAT 3 precision approach and landing applications. A United Airlines Boeing 737-300 (N304UA) was equipped with DGPS receiving equipment and additional computing capability provided by Stanford University. The test flights were conducted at NASA Ames Research Center's Crows Landing Flight Facility, Crows Landing, California. The flight test evaluation was based on completing 100 approaches and autolandings; 90 touch and go, and 10 terminating with a full stop. Two types of accuracy requirements were evaluated: 1) Total system error, based on the Required Navigation Performance (RNP), and 2) Navigation sensor error, based on ICAO requirements for the Microwave Landing System (MLS). All of the approaches and autolandings were evaluated against ground truth reference data provided by a laser tracker. Analysis of these approaches and autolandings shows that the Stanford University/United Airlines system met the requirements for a successful approach and autolanding 98 out of 100 approaches and autolandings, based on the total system error requirements as specified in the FAA CAT 3 Level 2 Flight Test Plan.
An Efficient Functional Test Generation Method For Processors Using Genetic Algorithms
NASA Astrophysics Data System (ADS)
Hudec, Ján; Gramatová, Elena
2015-07-01
The paper presents a new functional test generation method for processors testing based on genetic algorithms and evolutionary strategies. The tests are generated over an instruction set architecture and a processor description. Such functional tests belong to the software-oriented testing. Quality of the tests is evaluated by code coverage of the processor description using simulation. The presented test generation method uses VHDL models of processors and the professional simulator ModelSim. The rules, parameters and fitness functions were defined for various genetic algorithms used in automatic test generation. Functionality and effectiveness were evaluated using the RISC type processor DP32.
Fidelity of test development process within a national science grant
NASA Astrophysics Data System (ADS)
Brumfield, Teresa E.
In 2002, a math-science partnership (MSP) program was initiated by a national science grant. The purpose of the MSP program was to promote the development, implementation, and sustainability of promising partnerships among institutions of higher education, K-12 schools and school systems, as well as other important stakeholders. One of the funded projects included a teacher-scientist collaborative that instituted a professional development system to prepare teachers to use inquiry-based instructional modules. The MSP program mandated evaluations of its funded projects. One of the teacher-scientist collaborative project's outcomes specifically focused on teacher and student science content and process skills. In order to provide annual evidence of progress and to measure the impact of the project's efforts, and because no appropriate science tests were available to measure improvements in content knowledge of participating teachers and their students, the project contracted for the development of science tests. This dissertation focused on the process of test development within an evaluation and examined planned (i.e., expected) and actual (i.e., observed) test development, specifically concentrating on the factors that affected the actual test development process. Planned test development was defined as the process of creating tests according to the well-established test development procedures recommended by the AERA/APA/NCME 1999 Standards for Educational and Psychological Testing. Actual test development was defined as the process of creating tests as it actually took place. Because case study provides an in-depth, longitudinal examination of an event (i.e., case) in a naturalistic setting, it was selected as the appropriate methodology to examine the difference between planned and actual test development. The case (or unit of analysis) was the test development task, a task that was bounded by the context in which it occurred---and over which this researcher had no control---and by time. The purpose for studying the case was to gain a more in-depth, holistic understanding of the real-life test development task that took place within a project evaluation context. In particular, this case study investigated how the actual test development process was affected by: (1) the national and state (i.e., NC) science standards, (2) the NSF's definition of "evidence" in a project evaluation, (3) the MSP project's understanding of the role of the to-be-developed tests in their project evaluation, (4) the MSP project's understanding of the test development process, and (5) the MSP project's participants (e.g., teacher item-writers and scientists). From an investigation of this case, it was concluded that: (a) constructing psychometrically sound tests within an evaluation is not easy, (b) sufficient time and resources to construct such measures properly are seldom provided, and (c) test construction---at least within an evaluation---is not routine and unproblematic. Based upon the results from this case study, it was recommended that stakeholders (i.e., program managers, project directors, and evaluators) be familiar with the steps and standards used to develop psychometrically sound tests. Additionally, it was recommended that, for future research, a meta-analysis that examines only the test development process be conducted of all other MSP projects. A second suggested future research area was to establish a protocol that provides a systematic means by which to examine an existing or proposed MSP project for alignment with state science standards. Such a protocol would be cost-effective in that demonstrated alignment with state science standards would enable projects to use existing state science assessments, which must be in place, according to NCLB, by the 2007-2008 school year, to demonstrate student achievement. In this way, project directors and evaluators, typically with limited familiarity with the steps and standards by which psychometrically sound assessments are created, would not be placed in the role of test developer.
DOT National Transportation Integrated Search
2004-12-06
These are the appendices for the report describing the findings of the US DOT-sponsored evaluation of the Orlando (Florida) ORANGES multi-modal Field Operational Test (FOT); the report includes: a background description of the ORANGES FOT; the Evalua...
7 CFR 15b.24 - Evaluation and placement.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Education § 15b.24 Evaluation and placement. (a) Placement evaluation. A recipient that operates a public... speaking skills, the test results accurately reflect the student's aptitude or achievement level or..., manual or speaking skills (except where those skills are the factors that the test purports to measure...
7 CFR 15b.24 - Evaluation and placement.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Education § 15b.24 Evaluation and placement. (a) Placement evaluation. A recipient that operates a public... speaking skills, the test results accurately reflect the student's aptitude or achievement level or..., manual or speaking skills (except where those skills are the factors that the test purports to measure...
1981-1982 Evaluation Findings.
ERIC Educational Resources Information Center
Austin Independent School District, TX. Office of Research and Evaluation.
The findings in evaluation and testing activities of the Austin Independent School District (AISD) during the 1981-82 school year are summarized. The first section, "1982 at a Glance," discusses the evaluation findings as a whole. Final reports and abstracts of related reports on achievement test results are presented for the district…
Locking Nut with Stress-Distributing Insert
NASA Technical Reports Server (NTRS)
Daniels, Christopher C.
2010-01-01
Reusable holders have been devised for evaluating high-temperature, plasma-resistant re-entry materials, especially fabrics. Typical material samples tested support thermal-protection-system damage repair requiring evaluation prior to re-entry into terrestrial atmosphere. These tests allow evaluation of each material to withstand the most severe predicted re-entry conditions.
7 CFR 15b.24 - Evaluation and placement.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Education § 15b.24 Evaluation and placement. (a) Placement evaluation. A recipient that operates a public... speaking skills, the test results accurately reflect the student's aptitude or achievement level or..., manual or speaking skills (except where those skills are the factors that the test purports to measure...
7 CFR 15b.24 - Evaluation and placement.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Education § 15b.24 Evaluation and placement. (a) Placement evaluation. A recipient that operates a public... speaking skills, the test results accurately reflect the student's aptitude or achievement level or..., manual or speaking skills (except where those skills are the factors that the test purports to measure...
EMISSION TEST REPORT, OMSS FIELD TEST ON CARBON INJECTION FOR MERCURY CONTROL
The report discusses results of a parametric evaluation of powdered activated carbon for control of mercury (Hg) emission from a municipal waste cornbustor (MWC) equipped with a lime spray dryer absorber/fabric filter (SD/FF). The primary test objectives were to evaluate the effe...
Criteria to Evaluate Interpretive Guides for Criterion-Referenced Tests
ERIC Educational Resources Information Center
Trapp, William J.
2007-01-01
This project provides a list of criteria for which the contents of interpretive guides written for customized, criterion-referenced tests can be evaluated. The criteria are based on the "Standards for Educational and Psychological Testing" (1999) and examine the content breadth of interpretive guides. Interpretive guides written for…
DOT National Transportation Integrated Search
2012-03-01
This research study aims at evaluating the performance of base and subgrade soil in flexible pavements under repeated loading test conditions. For this purpose, an indoor cyclic plate load testing equipment was developed and used to conduct a series ...
DOT National Transportation Integrated Search
1999-04-01
The purpose of this study is to crash test and evaluate new or modified roadside safety hardware and, where necessary, redesign the devices to improve their impact performance. The three major areas addressed in this study are the impact performance ...
EVALUATION OF MIXING ENERGY IN LABORATORY FLASKS USED FOR DISPERSANT EFFECTIVENESS TESTING
The evaluation of dispersant effectiveness used for oil spills is commonly done using tests conducted in laboratory flasks. The success of a test relies on replication of the conditions at sea. We used a hot wire anemometer to characterize the turbulence characteristics in the s...
14 CFR 35.37 - Fatigue limits and evaluation.
Code of Federal Regulations, 2014 CFR
2014-01-01
... AIRWORTHINESS STANDARDS: PROPELLERS Tests and Inspections § 35.37 Fatigue limits and evaluation. This section does not apply to fixed-pitch wood propellers of conventional design. (a) Fatigue limits must be established by tests, or analysis based on tests, for propeller: (1) Hubs. (2) Blades. (3) Blade retention...
14 CFR 35.37 - Fatigue limits and evaluation.
Code of Federal Regulations, 2012 CFR
2012-01-01
... AIRWORTHINESS STANDARDS: PROPELLERS Tests and Inspections § 35.37 Fatigue limits and evaluation. This section does not apply to fixed-pitch wood propellers of conventional design. (a) Fatigue limits must be established by tests, or analysis based on tests, for propeller: (1) Hubs. (2) Blades. (3) Blade retention...
14 CFR 35.37 - Fatigue limits and evaluation.
Code of Federal Regulations, 2013 CFR
2013-01-01
... AIRWORTHINESS STANDARDS: PROPELLERS Tests and Inspections § 35.37 Fatigue limits and evaluation. This section does not apply to fixed-pitch wood propellers of conventional design. (a) Fatigue limits must be established by tests, or analysis based on tests, for propeller: (1) Hubs. (2) Blades. (3) Blade retention...
14 CFR 35.37 - Fatigue limits and evaluation.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AIRWORTHINESS STANDARDS: PROPELLERS Tests and Inspections § 35.37 Fatigue limits and evaluation. This section does not apply to fixed-pitch wood propellers of conventional design. (a) Fatigue limits must be established by tests, or analysis based on tests, for propeller: (1) Hubs. (2) Blades. (3) Blade retention...
Detection of CMOS bridging faults using minimal stuck-at fault test sets
NASA Technical Reports Server (NTRS)
Ijaz, Nabeel; Frenzel, James F.
1993-01-01
The performance of minimal stuck-at fault test sets at detecting bridging faults are evaluated. New functional models of circuit primitives are presented which allow accurate representation of bridging faults under switch-level simulation. The effectiveness of the patterns is evaluated using both voltage and current testing.
A significant amount of research is currently targeted to evaluate alternative test methods that may reduce, refine, or replace the use of animals, while ensuring human and environmental health and safety. It is important that the information gained from the alternative tests pr...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-15
... biomedical and life sciences research; and subject matter experts who voluntarily consent to be included in a... 1974; Science & Technology Directorate-001 Research, Development, Test, and Evaluation Records System.../Science and Technology Directorate-001 Research, Development, Test, and Evaluation System of Records...
Estimation of the Proportion of Genetic Variation Accounted for by DNA Tests
USDA-ARS?s Scientific Manuscript database
An increasingly relevant question in evaluating commercial DNA tests is "What proportion of the additive genetic variation in the target trait is accounted for by the test?" Therefore, several estimators of this quantity were evaluated by simulation of a population of 1000 animals with 100 sires, ea...
The report describes the development and evaluation of a large chamber test method for measuring emissions from dry-process photocopiers. The test method was developed in two phases. Phase 1 was a single-laboratory evaluation at Research Triangle Institute (RTI) using four, mid-r...
21 CFR 640.56 - Quality control test for potency.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., Center for Biologics Evaluation and Research, Food and Drug Administration. Such testing shall not be... Evaluation and Research, Food and Drug Administration. (d) If the average potency level of antihemophilic... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Quality control test for potency. 640.56 Section...
EVALUATION OF A TEST METHOD FOR MEASURING INDOOR AIR EMISSIONS FROM DRY-PROCESS PHOTOCOPIERS
A large chamber test method for measuring indoor air emissions from office equipment was developed, evaluated, and revised based on the initial testing of four dry-process photocopiers. Because all chambers may not necessarily produce similar results (e.g., due to differences in ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundstrom, B.; Shirazi, M.; Coddington, M.
2013-01-01
This paper describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through themore » use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.« less
Energy Storage Requirements & Challenges for Ground Vehicles
2010-03-18
Titinate Evaluation Cell Evaluation Battery Aging Phenomenon Battery SOC/SOH Determination Modeling ARM 100 LiIon APU Lion Cell Evaluation Cell...Advanced Batteries Fuels Th er m al Ma na ge m en t Radiators Heat Recovery Thermal Interface Materials Phase Change Cooling Advanced Electronics...in all energy storage Energy Storage Team Mission Battery Technology Evaluation Lab Module Test & Eval Cell Test & Eval 6UNCLASSIFIED Pacing Vehicle
Electronics systems test laboratory testing of shuttle communications systems
NASA Technical Reports Server (NTRS)
Stoker, C. J.; Bromley, L. K.
1985-01-01
Shuttle communications and tracking systems space to space and space to ground compatibility and performance evaluations are conducted in the NASA Johnson Space Center Electronics Systems Test Laboratory (ESTL). This evaluation is accomplished through systems verification/certification tests using orbiter communications hardware in conjunction with other shuttle communications and tracking external elements to evaluate end to end system compatibility and to verify/certify that overall system performance meets program requirements before manned flight usage. In this role, the ESTL serves as a multielement major ground test facility. The ESTL capability and program concept are discussed. The system test philosophy for the complex communications channels is described in terms of the major phases. Results of space to space and space to ground systems tests are presented. Several examples of the ESTL's unique capabilities to locate and help resolve potential problems are discussed in detail.
Baiochi, Eduardo; Camano, Luiz; Bordin, José Orlando
2005-01-01
This study evaluated fetomaternal hemorrhage (FMH) in 343 postpartum patients who required prophylaxis of Rh alloimmunization with anti-D immunoglobulin. The rosette test was applied to screen for patients needing quantitative determination of fetal blood transferred from the maternal circulation, which was then measured by the Kleihauer-Betke test (K-B). The rosette test was positive in 22 cases (6.4%). In five of these cases, K-B did not show fetomaternal hemorrhage (a 1.45% false-positive rate for the rosette test), and in one case the test was inconclusive. There were 8 cases with FMH < 10 ml (2.3%), 6 cases with FMH from 10 to 30 ml (1.7%), and two cases with FMH > 30 ml (0.58%), requiring a supplementary dose of anti-D. The study concludes that following the rosette test, additional evaluation of FMH using a quantitative test was unnecessary in 93.6% of the cases.
Counter unmanned aerial system testing and evaluation methodology
NASA Astrophysics Data System (ADS)
Kouhestani, C.; Woo, B.; Birch, G.
2017-05-01
Unmanned aerial systems (UAS) are increasing in flight times, ease of use, and payload sizes. Detection, classification, tracking, and neutralization of UAS is a necessary capability for infrastructure and facility protection. We discuss test and evaluation methodology developed at Sandia National Laboratories to establish a consistent, defendable, and unbiased means for evaluating counter unmanned aerial system (CUAS) technologies. The test approach described identifies test strategies, performance metrics, UAS types tested, key variables, and the necessary data analysis to accurately quantify the capabilities of CUAS technologies. The tests conducted, as defined by this approach, will allow for the determination of quantifiable limitations, strengths, and weaknesses in terms of detection, tracking, classification, and neutralization. Communicating the results of this testing in such a manner informs decisions by government sponsors and stakeholders that can be used to guide future investments and inform procurement, deployment, and advancement of such systems into their specific venues.
Development of a test protocol for evaluating EVA glove performance
NASA Technical Reports Server (NTRS)
Hinman, Elaine M.
1992-01-01
Testing gloved hand performance involves work from several disciplines. Evaluations performed in the course of reenabling a disabled hand, designing a robotic end effector or master controller, or hard-suit design have all yielded relevant information, and, in most cases, produced performance test methods. Most times, these test methods have been primarily oriented toward their parent discipline. For space operations, a comparative test which would provide a way to quantify pressure glove and end effector performance would be useful in dividing tasks between humans and robots. Such a test would have to rely heavily on sensored measurement, as opposed to questionnaires, to produce relevant data. However, at some point human preference would have to be taken into account. This paper presents a methodology for evaluating gloved hand performance which attempts to respond to these issues. Glove testing of a prototype glove design using this method is described.
Modern psychophysical tests to assess olfactory function.
Eibenstein, A; Fioretti, A B; Lena, C; Rosati, N; Amabile, G; Fusetti, M
2005-07-01
The sense of smell significantly contributes to quality of life. In recent years much progress has been made in understanding the biochemistry, physiology and pathology of the human olfactory system. Olfactory disorders may arise not only from upper airway phlogosis but also from neurodegenerative disease. Hyposmia may precede motor signs in Parkinson's disease and cognitive deficit in Alzheimer's disease. These findings suggest the complementary role of olfactory tests in the diagnosis and management of neurodegenerative diseases. In this report we present a review of modern olfactory tests and their clinical applications. Although rarely employed in routine clinical practice, the olfactory test evaluates the ability of odour identification and is a useful diagnostic tool for olfaction evaluation. Olfactory screening tests are also available. In this work we strongly recommend the importance of an ENT evaluation before the test administration and dissuade from a self-administration of an olfactory test.
ERIC Educational Resources Information Center
Ferguson, Richard L.
The focus of this study was upon the development and evaluation of a computer-assisted branched test to be used in making instructional decisions for individuals in the program of Individually Prescribed Instruction. A Branched Test is one in which the presentation of test items is contingent upon the previous responses of the examinee. The…
ERIC Educational Resources Information Center
Quaigrain, Kennedy; Arhin, Ato Kwamina
2017-01-01
Item analysis is essential in improving items which will be used again in later tests; it can also be used to eliminate misleading items in a test. The study focused on item and test quality and explored the relationship between difficulty index (p-value) and discrimination index (DI) with distractor efficiency (DE). The study was conducted among…
Putting Teeth into Open Architectures: Infrastructure for Reducing the Need for Retesting
2007-04-30
the test and evaluation team. This paper outlines new approaches to quality assurance and testing that are better suited for providing...reconfiguration. Testing of reusable subsystems is also subject to the above considerations and, similarly, requires new methods for effectively achieving...architectural model. Thus, fully realizing the open architecture vision requires a new paradigm for test and evaluation. We propose such a
Evaluation program for secondary spacecraft cells
NASA Technical Reports Server (NTRS)
Christy, D. E.
1972-01-01
The life cycle test of secondary spacecraft electric cells is discussed. The purpose of the tests is to insure that all cells put into the life cycle test meet the required specifications. The evaluation program gathers statistical information concerning cell performance characteristics and limitations. Weaknesses in cell design which are discovered during the tests are reported to research facilities in order to increase the service life of the cells.
ERIC Educational Resources Information Center
Filby, Nikola N.; Dishaw, Marilyn
Major analyses of the achievement tests used in the Beginning Teacher Evaluation Study were conducted to determine test reactivity to instruction. Reading and mathematics tests were administered to second and fifth grade children. Classroom teachers' records were examined to determine the amount of opportunity students had to learn the content…
McNulty, E.W.; Dwyer, F.J.; Ellersieck, Mark R.; Greer, E.I.; Ingersoll, C.G.; Rabeni, C.F.
1999-01-01
Standard methods for conducting toxicity tests imply that the condition of test organisms can be established using reference toxicity tests. However, only a limited number of studies have evaluated whether reference toxicity tests can actually be used to determine if organisms are in good condition at the start of a test. We evaluated the ability of reference toxicants to identify stress associated with starvation in laboratory populations of the amphipod Hyalella azteca using acute toxicity tests and four reference toxicants: KCl, CdCl2, sodium pentachlorophenate (NaPCP), and carbaryl. Stress associated with severe starvation was observed with exposure of amphipods to carbaryl or NaPCP but not with exposure to KCl or CdCl2 (i.e., lower LC50 with severe starvation). Although the LC50s for NaPCP and carbaryl were statistically different between starved and fed amphipods, this difference may not be biologically significant given the variability expected in acute lethality tests. Stress associated with sieving, heat shock, or cold shock of amphipods before the start of a test was not evident with exposure to carbaryl or KCl as reference toxicants. The chemicals evaluated in this study provided minimal information about the condition of the organisms used to start a toxicity test. Laboratories should periodically perform reference toxicity tests to assess the sensitivity of life stages or strains of test organisms. However, use of other test acceptability criteria required in standard methods such as minimum survival, growth, or reproduction of organisms in the control treatment at the end of a test, provides more useful information about the condition of organisms used to start a test compared to data generated from reference toxicity tests.
Further evaluation of traditional icing scaling methods
NASA Technical Reports Server (NTRS)
Anderson, David N.
1996-01-01
This report provides additional evaluations of two methods to scale icing test conditions; it also describes a hybrid technique for use when scaled conditions are outside the operating envelope of the test facility. The first evaluation is of the Olsen method which can be used to scale the liquid-water content in icing tests, and the second is the AEDC (Ruff) method which is used when the test model is less than full size. Equations for both scaling methods are presented in the paper, and the methods were evaluated by performing icing tests in the NASA Lewis Icing Research Tunnel (IRT). The Olsen method was tested using 53 cm diameter NACA 0012 airfoils. Tests covered liquid-water-contents which varied by as much as a factor of 1.8. The Olsen method was generally effective in giving scale ice shapes which matched the reference shapes for these tests. The AEDC method was tested with NACA 0012 airfoils with chords from 18 cm to 53 cm. The 53 cm chord airfoils were used in reference tests, and 1/2 and 1/3 scale tests were made at conditions determined by applying the AEDC scaling method. The scale and reference airspeeds were matched in these tests. The AEDC method was found to provide fairly effective scaling for 1/2 size tests, but for 1/3 size models, scaling was generally less effective. In addition to these two scaling methods, a hybrid approach was also tested in which the Olsen method was used to adjust the LWC after size was scaled using the constant Weber number method. This approach was found to be an effective way to test when scaled conditions would otherwise be outside the capability of the test facility.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ketusky, E.
The U.S. Department of Energy’s (DOE’s) Used Fuel Disposition Campaign (UFDC) Program has transported high-burnup nuclear sister fuel rods from a commercial nuclear power plant for purposes of evaluation and testing. The evaluation and testing of high-burnup used nuclear fuel is integral to DOE initiatives to collect information useful in determining the integrity of fuel cladding for future safe transportation of the fuel, and for determining the effects of aging, on the integrity of UNF subjected to extended storage and subsequent transportation. The UFDC Program, in collaboration with the U.S. Nuclear Regulatory Commission and the commercial nuclear industry, has obtainedmore » individual used nuclear fuel rods for testing. The rods have been received at Oak Ridge National Laboratory (ORNL) for both separate effects testing (SET) and small-scale testing (SST). To meet the research objectives, testing on multiple 6 inch fuel rod pins cut from the rods at ORNL will be performed at Pacific Northwest National Laboratory (PNNL). Up to 10 rod equivalents will be shipped. Options were evaluated for multiple shipments using the 10-160B (based on 4.5 rod equivalents) and a single shipment using the NAC-LWT. Based on the original INL/Virginia Power transfer agreement, the rods are assumed to 152 inches in length with a 0.374-inch diameter. This report provides a preliminary content evaluation for use of the 10-160B and NAC-LWT for transporting those fuel rod pins from ORNL to PNNL. This report documents the acceptability of using these packagings to transport the fuel segments from ORNL to PNNL based on the following evaluations: enrichment, A2 evaluation, Pu-239 FGE evaluation, heat load, shielding (both gamma and neutron), and content weight/structural evaluation.« less
Four hundred meters walking test in the evaluation of heart failure patients.
Zdrenghea, D; Beudean, Maria; Pop, Dana; Zdrenghea, V
2010-01-01
The best evaluation of the severity and prognosis of heart failure patients is obtained by the maximal exercise stress testing, but for the very large number of HF patients and for evaluation of their daily effort capacity submaximal stress testing, mainly 6 minutes walking test are used. The limit of 6mWT is that during it the patients are not motivated to walk and also, the periphery, so important for heart failure patients, is not equally involved. To compare a new fixed walking test-400m walking test with 6MWT and maximal exercise testing. There were investigated 20 patients with dilated cardiomyopathy (DCM). The patients were included in the study after the relief of the congestive syndrome. Each patient was submitted in three consecutive days to a maximal symptom-limited exercise stress test on cycloergometer, a six minutes walking test, a 400 meters walking test. The last one consisted of walking on a corridor 40 meters long, at a speed chosen by the patient himself. The results were expressed in seconds representing the necessary time to cover the established 400 meters of distance. During cycloergometer exercise stress test the calculated mean peak VO2 was 15.2 +/- 1.4 mlO2/kg/min (4.32 METs). The mean distance walked during 6MWT was 350 +/- 34m and the mean time needed to walk 400m (400mWT) was 300 +/- 27 seconds. The correlation between peak VO2 and distance walked during 6MWT was -0.40, a similar but negative value (r = -0.42) being registered between peak VO2 and time registered during 400mWT. Only weak correlation was registered between LVEF and all the three tests. In turn the correlation between distance registered during 6MWT and time registered during 400mWT was excellent: r = -0.60. 400mWT is a useful tool for the evaluation of submaximal effort capacity of CHF patients. Its value to evaluate exercise capacity is similar with that of the 6 MWT, but 400mWT can assure a better evaluation of peripheral involvement.
Fraze, J L; Uhrig, J D; Davis, K C; Taylor, M K; Lee, N R; Spoeth, S; Robinson, A; Smith, K; Johnston, J; McElroy, L
2009-09-01
To describe the application of seven core principles to the design and evaluation of a human immunodeficiency virus (HIV) testing social marketing campaign as a case study example. The Centers for Disease Control and Prevention (CDC) used a structured social marketing approach, informed by the Ecological Model, the Theory of Planned Behaviour and the Health Belief Model, to develop and evaluate a two-city campaign with print, radio and outdoor advertising; HIV telephone hotlines; an HIV website; community partnerships; and events to promote information seeking and HIV testing. The CDC applied seven core principles to design and evaluate the campaign, including formative research, the use of behavioural theories, audience segmentation, message design and pretesting, channel selection, process evaluation and outcome evaluation. Over 200 partners in both cities contributed significantly to campaign efforts. Key informant interviews indicated that, due to increased coordination, city infrastructures for HIV testing improved. More than 9600 individuals attended campaign events in both cities, with 1492 rapid HIV tests administered and 14 newly-identified HIV individuals. Overall, event attendees responded positively to campaign materials and events, and free HIV testing opportunities. The campaign significantly increased information-seeking behaviours in the form of hotline calls and web searches. Audience reaction and receptivity to the final campaign materials was very high. Exposure to campaign messages was associated with increases in key knowledge items, intentions to get tested, and peer-to-peer communication. The seven core principles, including formative research, behavioural theories and extensive partnerships, acted synergistically to help a campaign reach its target audience with compelling, relevant messages and motivate them to seek information and get an HIV test. Rapid testing removes many barriers by providing a testing process that can be accessed and acted upon quickly in response to media exposure. Findings suggest that modifying the campaign in future implementations to encourage the target audience to attend and participate in rapid testing events, while expanding the number and reach of such events, may have considerable potential to measurably increase testing behaviours.
1980-10-01
Organizations Compounds Tested Morphological Tests Toxic Substances Functional Tests rR ACT Cutlue OM v.a e sif nemooery ad Identify by block number) %MITRE has...demonstrated ability to evaluate and predict hepatic impairment rvsulting from toxicant exposures. This directory is a companion to Selected Short-Term...Hepatic Toxicity Tests, which describes the available hepatic testing protocols and assesses their suitability for a screening program. This direc
NASA Technical Reports Server (NTRS)
Bement, Laurence J.; Schimmel, Morry L.
1989-01-01
To overcome serious weaknesses in determining the performance of initiating devices, a novel 'ignitability test method', representing actual design interfaces and ignition materials, has been developed. Ignition device output consists of heat, light, gas an burning particles. Past research methods have evaluated these parameters individually. This paper describes the development and demonstration of an ignitability test method combining all these parameters, and the quantitative assessment of the ignition performance of two widely used percussion primers, the M42C1-PA101 and the M42C2-793. The ignition materials used for this evaluation were several powder, granule and pellet sizes of black powder and boron-potassium nitrate. This test method should be useful for performance evaluation of all initiator types, quality assurance, evaluation of ignition interfaces, and service life studies of initiators and ignition materials.
Standard test evaluation of graphite fiber/resin matrix composite materials for improved toughness
NASA Technical Reports Server (NTRS)
Chapman, Andrew J.
1984-01-01
Programs sponsored by NASA with the commercial transport manufacturers to develop a technology data base are required to design and build composite wing and fuselage structures. To realize the full potential of composite structures in these strength critical designs, material systems having improved ductility and interlaminar toughness are being sought. To promote systematic evaluation of new materials, NASA and the commercial transport manufacturers have selected and standardized a set of five common tests. These tests evaluate open hole tension and compression performance, compression performance after impact at an energy level of 20 ft-lb, and resistance to delamination. Ten toughened resin matrix/graphite fiber composites were evaluated using this series of tests, and their performance is compared with a widely used composite system.
Lourenço, J; Marques, S; Carvalho, F P; Oliveira, J; Malta, M; Santos, M; Gonçalves, F; Pereira, R; Mendo, S
2017-12-15
Active and abandoned uranium mining sites often create environmentally problematic situations, since they cause the contamination of all environmental matrices (air, soil and water) with stable metals and radionuclides. Due to their cytotoxic, genotoxic and teratogenic properties, the exposure to these contaminants may cause several harmful effects in living organisms. The Fish Embryo Acute Toxicity Test (FET) test was employed to evaluate the genotoxic and teratogenic potential of mine liquid effluents and sludge elutriates from a deactivated uranium mine. The aims were: a) to determine the risk of discharge of such wastes in the environment; b) the effectiveness of the chemical treatment applied to the uranium mine water, which is a standard procedure generally applied to liquid effluents from uranium mines and mills, to reduce its toxicological potential; c) the suitability of the FET test for the evaluation the toxicity of such wastes and the added value of including the evaluation of genotoxicity. Results showed that through the FET test it was possible to determine that both elutriates and effluents are genotoxic and also that the mine effluent is teratogenic at low concentrations. Additionally, liquid effluents and sludge elutriates affect other parameters namely, growth and hatching and that water pH alone played an important role in the hatching process. The inclusion of genotoxicity evaluation in the FET test was crucial to prevent the underestimation of the risks posed by some of the tested effluents/elutriates. Finally, it was possible to conclude that care should be taken when using benchmark values calculated for specific stressors to evaluate the risk posed by uranium mining wastes to freshwater ecosystems, due to their chemical complexity. Copyright © 2017 Elsevier B.V. All rights reserved.
Maggio, Maria Cristina; Corsello, Giovanni; Messina, Giuseppe; Iovane, Angelo; Palma, Antonio
2017-01-01
Background: Juvenile idiopathic arthritis is a main cause of physical disability and has high economic costs for society. The purpose of this study was to assess the fitness levels and the postural and balance deficits with a specific test battery. Methods: Fifty-six subjects were enrolled in this study. Thirty-nine healthy subjects were included in the control group and seventeen in the juvenile idiopathic arthritis group. All subjects were evaluated using a posturography system. The fitness level was evaluated with a battery of tests (Abalakov test, sit-up test, hand grip test, backsaver sit and reach, the toe touch test). An unpaired t-test was used to determine differences. Pearson’s correlation coefficient was used to evaluate the correlation between the tests. Results: The battery of tests demonstrated that subjects in the juvenile idiopathic arthritis group have lower fitness levels compared to the control group. The juvenile idiopathic arthritis group showed low postural control with respect to the control group. Pearson analysis of the juvenile idiopathic arthritis group data showed significant correlations between variables. Pearson’s results from the control group data showed a similar trend. Conclusions: The results suggest that the battery of tests used could be an appropriate tool. However, we highlight that these conclusions need to be supported by other studies with a larger population scale. PMID:28753965
Patti, Antonino; Maggio, Maria Cristina; Corsello, Giovanni; Messina, Giuseppe; Iovane, Angelo; Palma, Antonio
2017-07-19
Background: Juvenile idiopathic arthritis is a main cause of physical disability and has high economic costs for society. The purpose of this study was to assess the fitness levels and the postural and balance deficits with a specific test battery. Methods: Fifty-six subjects were enrolled in this study. Thirty-nine healthy subjects were included in the control group and seventeen in the juvenile idiopathic arthritis group. All subjects were evaluated using a posturography system. The fitness level was evaluated with a battery of tests (Abalakov test, sit-up test, hand grip test, backsaver sit and reach, the toe touch test). An unpaired t -test was used to determine differences. Pearson's correlation coefficient was used to evaluate the correlation between the tests. Results: The battery of tests demonstrated that subjects in the juvenile idiopathic arthritis group have lower fitness levels compared to the control group. The juvenile idiopathic arthritis group showed low postural control with respect to the control group. Pearson analysis of the juvenile idiopathic arthritis group data showed significant correlations between variables. Pearson's results from the control group data showed a similar trend. Conclusions: The results suggest that the battery of tests used could be an appropriate tool. However, we highlight that these conclusions need to be supported by other studies with a larger population scale.
NASA Astrophysics Data System (ADS)
Sussman, Joshua Michael
This three-paper dissertation explores problems with the use of standardized tests as outcome measures for the evaluation of instructional interventions in mathematics and science. Investigators commonly use students' scores on standardized tests to evaluate the impact of instructional programs designed to improve student achievement. However, evidence suggests that the standardized tests may not measure, or may not measure well, the student learning caused by the interventions. This problem is special case of a basic problem in applied measurement related to understanding whether a particular test provides accurate and useful information about the impact of an educational intervention. The three papers explore different aspects of the issue and highlight the potential benefits of (a) using particular research methods and of (b) implementing changes to educational policy that would strengthen efforts to reform instructional intervention in mathematics and science. The first paper investigates measurement problems related to the use of standardized tests in applied educational research. Analysis of the research projects funded by the Institute of Education Sciences (IES) Mathematics and Science Education Program permitted me to address three main research questions. One, how often are standardized tests used to evaluate new educational interventions? Two, do the tests appear to measure the same thing that the intervention teaches? Three, do investigators establish validity evidence for the specific uses of the test? The research documents potential problems and actual problems related to the use of standardized tests in leading applied research, and suggests changes to policy that would address measurement issues and improve the rigor of applied educational research. The second paper explores the practical consequences of misalignment between an outcome measure and an educational intervention in the context of summative evaluation. Simulated evaluation data and a psychometric model of alignment grounded in item response modeling generate the results that address the following research question: how do differences between what a test measures and what an intervention teaches influence the results of an evaluation? The simulation derives a functional relationship between alignment, defined as the match between the test and the intervention, and treatment sensitivity, defined as the statistical power for detecting the impact of an intervention. The paper presents a new model of the effect of misalignment on the results of an evaluation and recommendations for outcome measure selection. The third paper documents the educational effectiveness of the Learning Mathematics through Representations (LMR) lesson sequence for students classified as English Learners (ELs). LMR is a research-based curricular unit designed to support upper elementary students' understandings of integers and fractions, areas considered foundational for the development of higher mathematics. The experimental evaluation contains a multilevel analysis of achievement data from two assessments: a standardized test and a researcher-developed assessment. The study coordinates the two sources of research data with a theoretical mechanism of action in order to rigorously document the effectiveness and educational equity of LMR for ELs using multiple sources of information.
Repeatability study of replicate crash tests: A signal analysis approach.
Seppi, Jeremy; Toczyski, Jacek; Crandall, Jeff R; Kerrigan, Jason
2017-10-03
To provide an objective basis on which to evaluate the repeatability of vehicle crash test methods, a recently developed signal analysis method was used to evaluate correlation of sensor time history data between replicate vehicle crash tests. The goal of this study was to evaluate the repeatability of rollover crash tests performed with the Dynamic Rollover Test System (DRoTS) relative to other vehicle crash test methods. Test data from DRoTS tests, deceleration rollover sled (DRS) tests, frontal crash tests, frontal offset crash tests, small overlap crash tests, small overlap impact (SOI) crash tests, and oblique crash tests were obtained from the literature and publicly available databases (the NHTSA vehicle database and the Insurance Institute for Highway Safety TechData) to examine crash test repeatability. Signal analysis of the DRoTS tests showed that force and deformation time histories had good to excellent repeatability, whereas vehicle kinematics showed only fair repeatability due to the vehicle mounting method for one pair of tests and slightly dissimilar mass properties (2.2%) in a second pair of tests. Relative to the DRS, the DRoTS tests showed very similar or higher levels of repeatability in nearly all vehicle kinematic data signals with the exception of global X' (road direction of travel) velocity and displacement due to the functionality of the DRoTS fixture. Based on the average overall scoring metric of the dominant acceleration, DRoTS was found to be as repeatable as all other crash tests analyzed. Vertical force measures showed good repeatability and were on par with frontal crash barrier forces. Dynamic deformation measures showed good to excellent repeatability as opposed to poor repeatability seen in SOI and oblique deformation measures. Using the signal analysis method as outlined in this article, the DRoTS was shown to have the same or better repeatability of crash test methods used in government regulatory and consumer evaluation test protocols.