Sample records for evaluation testing technique

  1. Evaluating the dynamic response of in-flight thrust calculation techniques during throttle transients

    NASA Technical Reports Server (NTRS)

    Ray, Ronald J.

    1994-01-01

    New flight test maneuvers and analysis techniques for evaluating the dynamic response of in-flight thrust models during throttle transients have been developed and validated. The approach is based on the aircraft and engine performance relationship between thrust and drag. Two flight test maneuvers, a throttle step and a throttle frequency sweep, were developed and used in the study. Graphical analysis techniques, including a frequency domain analysis method, were also developed and evaluated. They provide quantitative and qualitative results. Four thrust calculation methods were used to demonstrate and validate the test technique. Flight test applications on two high-performance aircraft confirmed the test methods as valid and accurate. These maneuvers and analysis techniques were easy to implement and use. Flight test results indicate the analysis techniques can identify the combined effects of model error and instrumentation response limitations on the calculated thrust value. The methods developed in this report provide an accurate approach for evaluating, validating, or comparing thrust calculation methods for dynamic flight applications.

  2. Quality Control and Nondestructive Evaluation Techniques for Composites. Part 1. Overview of Characterization Techniques for Composite Reliability

    DTIC Science & Technology

    1982-05-01

    MONITORING AND MANAGEMENT , 34 7.0 NONDESTRUCTIVE EVALUATION ( NDE ) 37 8. 0 SURFACE NDE 44 9.0 PERFORMANCE AND PROOF TESTING 46 10.0 SUMMARY AND...Chemical Quality Assurance Testing 2. Processability Testing 3. Cure Monitoring and Management 4. Nondestructive Evaluation ( NDE ) 5. Performance and...the management concept for implementing the specific tests. Chemical analysis, nondestructive evaluation ( NDE ) and environmental fatigue testing of

  3. In-place cement stabilized base reconstruction techniques interim report : "construction and two year evaluation".

    DOT National Transportation Integrated Search

    2002-08-01

    The purpose of this research was to evaluate the effectiveness of soil cement shrinkage crack mitigation techniques. The contents of this report reflect an evaluation of the construction of the test sections and a two-year evaluation of the test sect...

  4. Non-destructive evaluation techniques, high temperature ceramic component parts for gas turbines

    NASA Technical Reports Server (NTRS)

    Reiter, H.; Hirsekorn, S.; Lottermoser, J.; Goebbels, K.

    1984-01-01

    This report concerns studies conducted on various tests undertaken on material without destroying the material. Tests included: microradiographic techniques, vibration analysis, high-frequency ultrasonic tests with the addition of evaluation of defects and structure through analysis of ultrasonic scattering data, microwave tests and analysis of sound emission.

  5. Comparative Stress Corrosion Cracking and General Corrosion Resistance of Annealed and Hardened 440 C Stainless Steel - New Techniques in Stress Corrosion Testing

    NASA Technical Reports Server (NTRS)

    Mendreck, M. J.; Hurless, B. E.; Torres, P. D.; Danford, M. D.

    1998-01-01

    The corrosion and stress corrosion cracking (SCC) characteristics of annealed and hardened 440C stainless steel were evaluated in high humidity and 3.5-percent NaCl solution. Corrosion testing consisted of an evaluation of flat plates, with and without grease, in high humidity, as well as electrochemical testing in 3.5-percent NaCl. Stress corrosion testing consisted of conventional, constant strain, smooth bar testing in high humidity in addition to two relatively new techniques under evaluation at MSFC. These techniques involve either incremental or constant rate increases in the load applied to a precracked SE(B) specimen, monitoring the crack-opening-displacement response for indications of crack growth. The electrochemical corrosion testing demonstrated an order of magnitude greater general corrosion rate in the annealed 440C. All techniques for stress corrosion testing showed substantially better SCC resistance in the annealed material. The efficacy of the new techniques for stress corrosion testing was demonstrated both by the savings in time and the ability to better quantify SCC data.

  6. Minor surgery in microgravity

    NASA Technical Reports Server (NTRS)

    Billica, Roger; Krupa, Debra T.; Stonestreet, Robert; Kizzee, Victor D.

    1991-01-01

    The purpose is to investigate and demonstrate equipment and techniques proposed for minor surgery on Space Station Freedom (SSF). The objectives are: (1) to test and evaluate methods of surgical instrument packaging and deployment; (2) to test and evaluate methods of surgical site preparation and draping; (3) to evaluate techniques of sterile procedure and maintaining sterile field; (4) to evaluate methods of trash management during medical/surgical procedures; and (4) to gain experience in techniques for performing surgery in microgravity. A KC-135 parabolic flight test was performed on March 30, 1990 with the goal of investigating and demonstrating surgical equipment and techniques under consideration for use on SSF. The flight followed the standard 40 parabola profile with 20 to 25 seconds of near-zero gravity in each parabola.

  7. Testing techniques for determining static mechanical properties of Pneumatic tires

    NASA Technical Reports Server (NTRS)

    Dodge, R. N.; Larson, R. B.; Clark, S. K.; Nybakken, G. H.

    1974-01-01

    Fore-aft, lateral, and vertical spring rates of model and full-scale pneumatic tires were evaluated by testing techniques generally employed by industry and various testing groups. The purpose of this experimental program was to investigate what effects the different testing techniques have on the measured values of these important static tire mechanical properties. The testing techniques included both incremental and continuous loadings applied at various rates over half, full, and repeated cycles. Of the three properties evaluated, the fore-aft stiffness was demonstrated to be the most affected by the different testing techniques used to obtain it. Appreciable differences in the fore-aft spring rates occurred using both the increment- and continuous-loading techniques; however, the most significant effect was attributed to variations in the size of the fore-aft force loop. The dependence of lateral stiffness values on testing techniques followed the same trends as that for fore-aft stiffness, except to a lesser degree. Vertical stiffness values were found to be nearly independent of testing procedures if the nonlinear portion of the vertical force-deflection curves is avoided.

  8. Evaluation of methods for rapid determination of freezing point of aviation fuels

    NASA Technical Reports Server (NTRS)

    Mathiprakasam, B.

    1982-01-01

    Methods for identification of the more promising concepts for the development of a portable instrument to rapidly determine the freezing point of aviation fuels are described. The evaluation process consisted of: (1) collection of information on techniques previously used for the determination of the freezing point, (2) screening and selection of these techniques for further evaluation of their suitability in a portable unit for rapid measurement, and (3) an extensive experimental evaluation of the selected techniques and a final selection of the most promising technique. Test apparatuses employing differential thermal analysis and the change in optical transparency during phase change were evaluated and tested. A technique similar to differential thermal analysis using no reference fuel was investigated. In this method, the freezing point was obtained by digitizing the data and locating the point of inflection. Results obtained using this technique compare well with those obtained elsewhere using different techniques. A conceptual design of a portable instrument incorporating this technique is presented.

  9. Wide Panel Testing Technique for Evaluating Repair Weld Strengths

    NASA Technical Reports Server (NTRS)

    Rogers, Patrick R.; Bynum, Julian E.; Shah, Sandeep R.

    1998-01-01

    This paper describes a new tensile testing technique for evaluating the overall effect of a repair weld on the strength of a welded joint. Previously, repair weld strengths have been evaluated using one-inch width tensile specimens, but this technique does not capture all of the effects that result from a repair. The new technique involves testing of "wide panel" tensile specimens which contain the full length of a repair weld within a longer initial weld, allowing the specimen to capture the combined effects of residual stresses, local strength degradation, and load redistribution around a repair. The development of strains in the repair area of standard aluminum alloy specimens and new high-performance aluminum-lithium alloy specimens was observed and evaluated using photoelastic material. The results of this evaluation show an increased sensitivity to repair welding residual stresses in the aluminum-lithium alloy specimens.

  10. Holographic Techniques for Nondestructive Testing of Tires

    DOT National Transportation Integrated Search

    1972-04-01

    Holographic interferometric techniques were used in a development program to evaluate the feasibility of the technique in the nondestructive testing (NDT) of commercial automobile tires. Passenger tires with built-in defects were holographically insp...

  11. Practical Framework for an Electron Beam Induced Current Technique Based on a Numerical Optimization Approach

    NASA Astrophysics Data System (ADS)

    Yamaguchi, Hideshi; Soeda, Takeshi

    2015-03-01

    A practical framework for an electron beam induced current (EBIC) technique has been established for conductive materials based on a numerical optimization approach. Although the conventional EBIC technique is useful for evaluating the distributions of dopants or crystal defects in semiconductor transistors, issues related to the reproducibility and quantitative capability of measurements using this technique persist. For instance, it is difficult to acquire high-quality EBIC images throughout continuous tests due to variation in operator skill or test environment. Recently, due to the evaluation of EBIC equipment performance and the numerical optimization of equipment items, the constant acquisition of high contrast images has become possible, improving the reproducibility as well as yield regardless of operator skill or test environment. The technique proposed herein is even more sensitive and quantitative than scanning probe microscopy, an imaging technique that can possibly damage the sample. The new technique is expected to benefit the electrical evaluation of fragile or soft materials along with LSI materials.

  12. On the Performance Evaluation of 3D Reconstruction Techniques from a Sequence of Images

    NASA Astrophysics Data System (ADS)

    Eid, Ahmed; Farag, Aly

    2005-12-01

    The performance evaluation of 3D reconstruction techniques is not a simple problem to solve. This is not only due to the increased dimensionality of the problem but also due to the lack of standardized and widely accepted testing methodologies. This paper presents a unified framework for the performance evaluation of different 3D reconstruction techniques. This framework includes a general problem formalization, different measuring criteria, and a classification method as a first step in standardizing the evaluation process. Performance characterization of two standard 3D reconstruction techniques, stereo and space carving, is also presented. The evaluation is performed on the same data set using an image reprojection testing methodology to reduce the dimensionality of the evaluation domain. Also, different measuring strategies are presented and applied to the stereo and space carving techniques. These measuring strategies have shown consistent results in quantifying the performance of these techniques. Additional experiments are performed on the space carving technique to study the effect of the number of input images and the camera pose on its performance.

  13. Comparison of techniques for detecting antigens of Giardia lamblia and Cryptosporidium parvum in faeces.

    PubMed Central

    Tee, G H; Moody, A H; Cooke, A H; Chiodini, P L

    1993-01-01

    AIM--To compare the use of commercial monoclonal antibody test systems--the Giardia CEL IF test and the Crypto CEL IF test--for the detection of Giardia lamblia and Cryptosporidium parvum antigens in faeces with conventional techniques. METHODS--Sensitivity and specificity were evaluated using preparations of cysts of G lamblia and purified oocysts of C parvum. Evaluation of 59 random faecal samples passing through the Department of Clinical Parasitology, Hospital for Tropical Diseases, London, was carried out for both organisms. RESULTS--The fluorescence staining techniques proved more sensitive than other tests routinely used for diagnosis. PMID:8331181

  14. Perspectives of SiC-Based Ceramic Composites and Their Applications to Fusion Reactors 5.Development of Evaluation and Application Techniques of SiC⁄SiC Composites for Fusion Reactors

    NASA Astrophysics Data System (ADS)

    Hinoki, Tatsuya

    Evaluation techniques and mechanical properties of silicon carbide composites (SiC⁄SiC composites) reinforced with highly crystalline fibers are reviewed for fusion applications. The SiC⁄SiC composites used were fabricated by means of the CVI method. The evaluation includes in-plane tensile strength by in-plane tensile test, transthickness tensile strength by transthickness tensile test and diametral compression test and shear strength by compression test using double-notched specimen. All tests were successfully conducted using small specimens for neutron irradiation experiment. As application technique, the novel tungsten(W) coating technique on SiC is reviewed. The W powder melted by high power lamp in a few seconds and formed coating on SiC. No thick reaction layers of WC and W5Si3, which are formed by the other coating methods, were formed by this method.

  15. Test techniques for evaluating flight displays

    NASA Technical Reports Server (NTRS)

    Haworth, Loran A.; Newman, Richard L.

    1993-01-01

    The rapid development of graphics technology allows for greater flexibility in aircraft displays, but display evaluation techniques have not kept pace. Historically, display evaluation has been based on subjective opinion and not on the actual aircraft/pilot performance. Existing electronic display specifications and evaluation techniques are reviewed. A display rating technique analogous to handling qualities ratings was developed and is recommended for future evaluations. The choice of evaluation pilots is also discussed and the use of a limited number of trained evaluators is recommended over the use of a large number of operational pilots.

  16. Flight testing techniques for the evaluation of light aircraft stability derivatives: A review and analysis

    NASA Technical Reports Server (NTRS)

    Smetana, F. O.; Summery, D. C.; Johnson, W. D.

    1972-01-01

    Techniques quoted in the literature for the extraction of stability derivative information from flight test records are reviewed. A recent technique developed at NASA's Langley Research Center was regarded as the most productive yet developed. Results of tests of the sensitivity of this procedure to various types of data noise and to the accuracy of the estimated values of the derivatives are reported. Computer programs for providing these initial estimates are given. The literature review also includes a discussion of flight test measuring techniques, instrumentation, and piloting techniques.

  17. Measurement Techniques and Instruments Suitable for Life-prediction Testing of Photovoltaic Arrays

    NASA Technical Reports Server (NTRS)

    Noel, G. T.; Wood, V. E.; Mcginniss, V. D.; Hassell, J. A.; Richard, N. A.; Gaines, G. B.; Carmichael, D. C.

    1979-01-01

    The validation of a 20-year service life for low-cost photovoltaic arrays is a critical requirement in the Low-Cost Solar Array (LSA) Project. The validation is accomplished through accelerated life-prediction tests. A two-phase study was conducted to address the needs before such tests are carried out. The results and recommended techniques from the Phase 1 investigation are summarized in the appendix. Phase 2 of the study is covered in this report and consisted of experimental evaluations of three techniques selected from these recommended as a results of the Phase 1 findings. The three techniques evaluated were specular and nonspecular optical reflectometry, chemiluminescence measurements, and electric current noise measurements.

  18. Development of an invitro technique to use mouse embryonic stem cell in evaluating effects of xenobiotics

    EPA Science Inventory

    Our goal has been to develop a high-throughput, in vitro technique for evaluating the effects of xenobiotics using mouse embryonic stem cells (mESCs). We began with the Embryonic Stem Cell Test (EST), which is used to predict the embryotoxic potential of a test compound by combin...

  19. Aircraft flight test trajectory control

    NASA Technical Reports Server (NTRS)

    Menon, P. K. A.; Walker, R. A.

    1988-01-01

    Two design techniques for linear flight test trajectory controllers (FTTCs) are described: Eigenstructure assignment and the minimum error excitation technique. The two techniques are used to design FTTCs for an F-15 aircraft model for eight different maneuvers at thirty different flight conditions. An evaluation of the FTTCs is presented.

  20. Manufacturing Process Developments for Regeneratively-Cooled Channel Wall Rocket Nozzles

    NASA Technical Reports Server (NTRS)

    Gradl, Paul; Brandsmeier, Will

    2016-01-01

    Regeneratively cooled channel wall nozzles incorporate a series of integral coolant channels to contain the coolant to maintain adequate wall temperatures and expand hot gas providing engine thrust and specific impulse. NASA has been evaluating manufacturing techniques targeting large scale channel wall nozzles to support affordability of current and future liquid rocket engine nozzles and thrust chamber assemblies. The development of these large scale manufacturing techniques focus on the liner formation, channel slotting with advanced abrasive water-jet milling techniques and closeout of the coolant channels to replace or augment other cost reduction techniques being evaluated for nozzles. NASA is developing a series of channel closeout techniques including large scale additive manufacturing laser deposition and explosively bonded closeouts. A series of subscale nozzles were completed evaluating these processes. Fabrication of mechanical test and metallography samples, in addition to subscale hardware has focused on Inconel 625, 300 series stainless, aluminum alloys as well as other candidate materials. Evaluations of these techniques are demonstrating potential for significant cost reductions for large scale nozzles and chambers. Hot fire testing is planned using these techniques in the future.

  1. Screening fungicides for use in fish culture: Evaluation of the agar plug transfer, cellophane transfer, and agar dilution methods

    USGS Publications Warehouse

    Bailey, Tom A.

    1983-01-01

    The reliability, reproducibility, and usefulness of three screening methods -- the cellophane transfer, the agar plug transfer, and the agar dilution -- to screen aquatic fungicides were evaluated. Achlya flagellata and Saprolegnia hypogyna were exposed to 1, 10, and 100 mg/L of malachite green to test each method. The cellophane transfer and agar plug transfer techniques had similar reliability and reproducibility in rating fungicidal activity, and were both superior to the agar dilution technique. The agar plug transfer and agar dilution techniques adequately projected in vivo activity of malachite green, but the cellophane transfer technique overestimated its activity. Overall, the agar plug transfer technique most accurately rated the activity of malachite green and was the easiest test to perform. It therefore appears to be the method of choice for testing aquatic fungicides.

  2. Ground Vibration Test Planning and Pre-Test Analysis for the X-33 Vehicle

    NASA Technical Reports Server (NTRS)

    Bedrossian, Herand; Tinker, Michael L.; Hidalgo, Homero

    2000-01-01

    This paper describes the results of the modal test planning and the pre-test analysis for the X-33 vehicle. The pre-test analysis included the selection of the target modes, selection of the sensor and shaker locations and the development of an accurate Test Analysis Model (TAM). For target mode selection, four techniques were considered, one based on the Modal Cost technique, one based on Balanced Singular Value technique, a technique known as the Root Sum Squared (RSS) method, and a Modal Kinetic Energy (MKE) approach. For selecting sensor locations, four techniques were also considered; one based on the Weighted Average Kinetic Energy (WAKE), one based on Guyan Reduction (GR), one emphasizing engineering judgment, and one based on an optimum sensor selection technique using Genetic Algorithm (GA) search technique combined with a criteria based on Hankel Singular Values (HSV's). For selecting shaker locations, four techniques were also considered; one based on the Weighted Average Driving Point Residue (WADPR), one based on engineering judgment and accessibility considerations, a frequency response method, and an optimum shaker location selection based on a GA search technique combined with a criteria based on HSV's. To evaluate the effectiveness of the proposed sensor and shaker locations for exciting the target modes, extensive numerical simulations were performed. Multivariate Mode Indicator Function (MMIF) was used to evaluate the effectiveness of each sensor & shaker set with respect to modal parameter identification. Several TAM reduction techniques were considered including, Guyan, IRS, Modal, and Hybrid. Based on a pre-test cross-orthogonality checks using various reduction techniques, a Hybrid TAM reduction technique was selected and was used for all three vehicle fuel level configurations.

  3. Standardized pivot shift test improves measurement accuracy.

    PubMed

    Hoshino, Yuichi; Araujo, Paulo; Ahlden, Mattias; Moore, Charity G; Kuroda, Ryosuke; Zaffagnini, Stefano; Karlsson, Jon; Fu, Freddie H; Musahl, Volker

    2012-04-01

    The variability of the pivot shift test techniques greatly interferes with achieving a quantitative and generally comparable measurement. The purpose of this study was to compare the variation of the quantitative pivot shift measurements with different surgeons' preferred techniques to a standardized technique. The hypothesis was that standardizing the pivot shift test would improve consistency in the quantitative evaluation when compared with surgeon-specific techniques. A whole lower body cadaveric specimen was prepared to have a low-grade pivot shift on one side and high-grade pivot shift on the other side. Twelve expert surgeons performed the pivot shift test using (1) their preferred technique and (2) a standardized technique. Electromagnetic tracking was utilized to measure anterior tibial translation and acceleration of the reduction during the pivot shift test. The variation of the measurement was compared between the surgeons' preferred technique and the standardized technique. The anterior tibial translation during pivot shift test was similar between using surgeons' preferred technique (left 24.0 ± 4.3 mm; right 15.5 ± 3.8 mm) and using standardized technique (left 25.1 ± 3.2 mm; right 15.6 ± 4.0 mm; n.s.). However, the variation in acceleration was significantly smaller with the standardized technique (left 3.0 ± 1.3 mm/s(2); right 2.5 ± 0.7 mm/s(2)) compared with the surgeons' preferred technique (left 4.3 ± 3.3 mm/s(2); right 3.4 ± 2.3 mm/s(2); both P < 0.01). Standardizing the pivot shift test maneuver provides a more consistent quantitative evaluation and may be helpful in designing future multicenter clinical outcome trials. Diagnostic study, Level I.

  4. Comparative evaluation between anatomic and non-anatomic lateral ligament reconstruction techniques in the ankle joint: A computational study.

    PubMed

    Purevsuren, Tserenchimed; Batbaatar, Myagmarbayar; Khuyagbaatar, Batbayar; Kim, Kyungsoo; Kim, Yoon Hyuk

    2018-03-12

    Biomechanical studies have indicated that the conventional non-anatomic reconstruction techniques for lateral ankle sprain (LAS) tend to restrict subtalar joint motion compared to intact ankle joints. Excessive restriction in subtalar motion may lead to chronic pain, functional difficulties, and development of osteoarthritis. Therefore, various anatomic surgical techniques to reconstruct both the anterior talofibular and calcaneofibular ligaments have been introduced. In this study, ankle joint stability was evaluated using multibody computational ankle joint model to assess two new anatomic reconstruction and three popular non-anatomic reconstruction techniques. An LAS injury, three popular non-anatomic reconstruction models (Watson-Jones, Evans, and Chrisman-Snook), and two common types of anatomic reconstruction models were developed based on the intact ankle model. The stability of ankle in both talocrural and subtalar joint were evaluated under anterior drawer test (150 N anterior force), inversion test (3 Nm inversion moment), internal rotational test (3 Nm internal rotation moment), and the combined loading test (9 Nm inversion and internal moment as well as 1800 N compressive force). Our overall results show that the two anatomic reconstruction techniques were superior to the non-anatomic reconstruction techniques in stabilizing both talocrural and subtalar joints. Restricted subtalar joint motion, which mainly observed in Watson-Jones and Chrisman-Snook techniques, was not shown in the anatomical reconstructions. Evans technique was beneficial for subtalar joint as it does not restrict subtalar motion, though Evans technique was insufficient for restoring talocrural joint inversion. The anatomical reconstruction techniques best recovered ankle stability.

  5. Radio-controlled model design and testing techniques for stall/spin evaluation of general-aviation aircraft

    NASA Technical Reports Server (NTRS)

    Burk, S. M., Jr.; Wilson, C. F., Jr.

    1975-01-01

    A relatively inexpensive radio-controlled model stall/spin test technique was developed. Operational experiences using the technique are presented. A discussion of model construction techniques, spin-recovery parachute system, data recording system, and movie camera tracking system is included. Also discussed are a method of measuring moments of inertia, scaling of engine thrust, cost and time required to conduct a program, and examples of the results obtained from the flight tests.

  6. Nondestructive evaluation of MoDOT bridge decks : pilot study.

    DOT National Transportation Integrated Search

    2014-03-01

    This research has examined the use of nondestructive techniques for concrete bridge deck condition : assessments. The primary nondestructive testing/evaluation (NDT/NDE) technique utilized in this research : was ground-coupled ground penetrating rada...

  7. Nondestructive evaluation of MoDOT bridge decks : pilot study.

    DOT National Transportation Integrated Search

    2014-03-01

    This research has examined the use of nondestructive techniques for concrete bridge deck condition assessments. The primary nondestructive : testing/evaluation (NDT/NDE) technique utilized in this research was ground-coupled ground penetrating radar ...

  8. Vortex sensing tests at NAFEC.

    DOT National Transportation Integrated Search

    1972-01-01

    The report describes the results of a series of tests to determine and evaluate three experimental techniques for remote sensing of the wing-tip vortices generated by heavy commercial and military aircraft. These techniques involved a pulsed, bistati...

  9. Evaluation Applied to Reliability Analysis of Reconfigurable, Highly Reliable, Fault-Tolerant, Computing Systems for Avionics

    NASA Technical Reports Server (NTRS)

    Migneault, G. E.

    1979-01-01

    Emulation techniques are proposed as a solution to a difficulty arising in the analysis of the reliability of highly reliable computer systems for future commercial aircraft. The difficulty, viz., the lack of credible precision in reliability estimates obtained by analytical modeling techniques are established. The difficulty is shown to be an unavoidable consequence of: (1) a high reliability requirement so demanding as to make system evaluation by use testing infeasible, (2) a complex system design technique, fault tolerance, (3) system reliability dominated by errors due to flaws in the system definition, and (4) elaborate analytical modeling techniques whose precision outputs are quite sensitive to errors of approximation in their input data. The technique of emulation is described, indicating how its input is a simple description of the logical structure of a system and its output is the consequent behavior. The use of emulation techniques is discussed for pseudo-testing systems to evaluate bounds on the parameter values needed for the analytical techniques.

  10. Flash X-ray with image enhancement applied to combustion events

    NASA Astrophysics Data System (ADS)

    White, K. J.; McCoy, D. G.

    1983-10-01

    Flow visualization of interior ballistic processes by use of X-rays has placed more stringent requirements on flash X-ray techniques. The problem of improving radiographic contrast of propellants in X-ray transparent chambers was studied by devising techniques for evaluating, measuring and reducing the effects of scattering from both the test object and structures in the test area. X-ray film and processing is reviewed and techniques for evaluating and calibrating these are outlined. Finally, after X-ray techniques were optimized, the application of image enhancement processing which can improve image quality is described. This technique was applied to X-ray studies of the combustion of very high burning rate (VHBR) propellants and stick propellant charges.

  11. Evaluation Techniques for Individualized Instruction: Development and Formative Testing.

    ERIC Educational Resources Information Center

    Bedient, Douglas; And Others

    1986-01-01

    Steps used in the formative evaluation of a project designed to incorporate self-instructional materials in an introductory zoology course included techniques which: (1) involved colleagues in the material development; (2) assessed relevant student characteristics, expectations, and evaluations; and (3) were used in the examinations. (MBR)

  12. Rasch Analysis for Instrument Development: Why, When, and How?

    PubMed Central

    Boone, William J.

    2016-01-01

    This essay describes Rasch analysis psychometric techniques and how such techniques can be used by life sciences education researchers to guide the development and use of surveys and tests. Specifically, Rasch techniques can be used to document and evaluate the measurement functioning of such instruments. Rasch techniques also allow researchers to construct “Wright maps” to explain the meaning of a test score or survey score and develop alternative forms of tests and surveys. Rasch techniques provide a mechanism by which the quality of life sciences–related tests and surveys can be optimized and the techniques can be used to provide a context (e.g., what topics a student has mastered) when explaining test and survey results. PMID:27856555

  13. Transverse vibration techniques : logs to structural systems

    Treesearch

    Robert J. Ross

    2008-01-01

    Transverse vibration as a nondestructive testing and evaluation technique was first examined in the early 1960s. Initial research and development efforts focused on clear wood, lumber, and laminated products. Out of those efforts, tools were developed that are used today to assess lumber properties. Recently, use of this technique has been investigated for evaluating a...

  14. Test Input Generation for Red-Black Trees using Abstraction

    NASA Technical Reports Server (NTRS)

    Visser, Willem; Pasareanu, Corina S.; Pelanek, Radek

    2005-01-01

    We consider the problem of test input generation for code that manipulates complex data structures. Test inputs are sequences of method calls from the data structure interface. We describe test input generation techniques that rely on state matching to avoid generation of redundant tests. Exhaustive techniques use explicit state model checking to explore all the possible test sequences up to predefined input sizes. Lossy techniques rely on abstraction mappings to compute and store abstract versions of the concrete states; they explore under-approximations of all the possible test sequences. We have implemented the techniques on top of the Java PathFinder model checker and we evaluate them using a Java implementation of red-black trees.

  15. Improved Sectional Image Analysis Technique for Evaluating Fiber Orientations in Fiber-Reinforced Cement-Based Materials.

    PubMed

    Lee, Bang Yeon; Kang, Su-Tae; Yun, Hae-Bum; Kim, Yun Yong

    2016-01-12

    The distribution of fiber orientation is an important factor in determining the mechanical properties of fiber-reinforced concrete. This study proposes a new image analysis technique for improving the evaluation accuracy of fiber orientation distribution in the sectional image of fiber-reinforced concrete. A series of tests on the accuracy of fiber detection and the estimation performance of fiber orientation was performed on artificial fiber images to assess the validity of the proposed technique. The validation test results showed that the proposed technique estimates the distribution of fiber orientation more accurately than the direct measurement of fiber orientation by image analysis.

  16. Effectiveness of Shield Termination Techniques Tested with TEM Cell and Bulk Current Injection

    NASA Technical Reports Server (NTRS)

    Bradley, Arthur T.; Hare, Richard J.

    2009-01-01

    This paper presents experimental results of the effectiveness of various shield termination techniques. Each termination technique is evaluated by two independent noise injection methods; transverse electromagnetic (TEM) cell operated from 3 MHz 400 MHz, and bulk current injection (BCI) operated from 50 kHz 400 MHz. Both single carrier and broadband injection tests were investigated. Recommendations as to how to achieve the best shield transfer impedance (i.e. reduced coupled noise) are made based on the empirical data. Finally, the noise injection techniques themselves are indirectly evaluated by comparing the results obtained from the TEM Cell to those from BCI.

  17. Improved Sectional Image Analysis Technique for Evaluating Fiber Orientations in Fiber-Reinforced Cement-Based Materials

    PubMed Central

    Lee, Bang Yeon; Kang, Su-Tae; Yun, Hae-Bum; Kim, Yun Yong

    2016-01-01

    The distribution of fiber orientation is an important factor in determining the mechanical properties of fiber-reinforced concrete. This study proposes a new image analysis technique for improving the evaluation accuracy of fiber orientation distribution in the sectional image of fiber-reinforced concrete. A series of tests on the accuracy of fiber detection and the estimation performance of fiber orientation was performed on artificial fiber images to assess the validity of the proposed technique. The validation test results showed that the proposed technique estimates the distribution of fiber orientation more accurately than the direct measurement of fiber orientation by image analysis. PMID:28787839

  18. A Human Reliability Based Usability Evaluation Method for Safety-Critical Software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phillippe Palanque; Regina Bernhaupt; Ronald Boring

    2006-04-01

    Recent years have seen an increasing use of sophisticated interaction techniques including in the field of safety critical interactive software [8]. The use of such techniques has been required in order to increase the bandwidth between the users and systems and thus to help them deal efficiently with increasingly complex systems. These techniques come from research and innovation done in the field of humancomputer interaction (HCI). A significant effort is currently being undertaken by the HCI community in order to apply and extend current usability evaluation techniques to these new kinds of interaction techniques. However, very little has been donemore » to improve the reliability of software offering these kinds of interaction techniques. Even testing basic graphical user interfaces remains a challenge that has rarely been addressed in the field of software engineering [9]. However, the non reliability of interactive software can jeopardize usability evaluation by showing unexpected or undesired behaviors. The aim of this SIG is to provide a forum for both researchers and practitioners interested in testing interactive software. Our goal is to define a roadmap of activities to cross fertilize usability and reliability testing of these kinds of systems to minimize duplicate efforts in both communities.« less

  19. Subcritical flutter testing and system identification

    NASA Technical Reports Server (NTRS)

    Houbolt, J. C.

    1974-01-01

    Treatment is given of system response evaluation, especially in application to subcritical flight and wind tunnel flutter testing of aircraft. An evaluation is made of various existing techniques, in conjuction with a companion survey which reports theoretical and analog experiments made to study the identification of system response characteristics. Various input excitations are considered, and new techniques for analyzing response are explored, particularly in reference to the prevalent practical case where unwanted input noise is present, such as caused by gusts or wind tunnel turbulence. Further developments are also made of system parameter identification techniques.

  20. Development of Modal Test Techniques for Validation of a Solar Sail Design

    NASA Technical Reports Server (NTRS)

    Gaspar, James L.; Mann, Troy; Behun, Vaughn; Wilkie, W. Keats; Pappa, Richard

    2004-01-01

    This paper focuses on the development of modal test techniques for validation of a solar sail gossamer space structure design. The major focus is on validating and comparing the capabilities of various excitation techniques for modal testing solar sail components. One triangular shaped quadrant of a solar sail membrane was tested in a 1 Torr vacuum environment using various excitation techniques including, magnetic excitation, and surface-bonded piezoelectric patch actuators. Results from modal tests performed on the sail using piezoelectric patches at different positions are discussed. The excitation methods were evaluated for their applicability to in-vacuum ground testing and to the development of on orbit flight test techniques. The solar sail membrane was tested in the horizontal configuration at various tension levels to assess the variation in frequency with tension in a vacuum environment. A segment of a solar sail mast prototype was also tested in ambient atmospheric conditions using various excitation techniques, and these methods are also assessed for their ground test capabilities and on-orbit flight testing.

  1. Bridge A1187 : Missouri S&T nondestructive evaluation of bridge decks - pilot study.

    DOT National Transportation Integrated Search

    2014-03-01

    This research has examined the use of nondestructive techniques for concrete bridge deck condition : assessments. The primary nondestructive testing/evaluation (NDT/NDE) technique utilized in this research : was ground-coupled ground penetrating rada...

  2. Bridge A3406 : Missouri S&T nondestructive evaluation of bridge decks - pilot study.

    DOT National Transportation Integrated Search

    2014-03-01

    This research has examined the use of nondestructive techniques for concrete bridge deck condition : assessments. The primary nondestructive testing/evaluation (NDT/NDE) technique utilized in this research : was ground-coupled ground penetrating rada...

  3. Bridge A1479 : Missouri S&T nondestructive evaluation of bridge decks - pilot study.

    DOT National Transportation Integrated Search

    2014-03-01

    This research has examined the use of nondestructive techniques for concrete bridge deck condition : assessments. The primary nondestructive testing/evaluation (NDT/NDE) technique utilized in this research : was ground-coupled ground penetrating rada...

  4. Bridge A2966 : Missouri S&T nondestructive evaluation of bridge decks - pilot study.

    DOT National Transportation Integrated Search

    2014-03-01

    This research has examined the use of nondestructive techniques for concrete bridge deck condition : assessments. The primary nondestructive testing/evaluation (NDT/NDE) technique utilized in this research : was ground-coupled ground penetrating rada...

  5. Bridge A2111 : Missouri S&T nondestructive evaluation of bridge decks - pilot study.

    DOT National Transportation Integrated Search

    2014-03-01

    This research has examined the use of nondestructive techniques for concrete bridge deck condition : assessments. The primary nondestructive testing/evaluation (NDT/NDE) technique utilized in this research : was ground-coupled ground penetrating rada...

  6. Bridge A1297 : Missouri S&T nondestructive evaluation of bridge decks - pilot study.

    DOT National Transportation Integrated Search

    2014-03-01

    This research has examined the use of nondestructive techniques for concrete bridge deck condition : assessments. The primary nondestructive testing/evaluation (NDT/NDE) technique utilized in this research : was ground-coupled ground penetrating rada...

  7. Bridge A1193 : Missouri S&T nondestructive evaluation of bridge decks - pilot study.

    DOT National Transportation Integrated Search

    2014-03-01

    This research has examined the use of nondestructive techniques for concrete bridge deck condition : assessments. The primary nondestructive testing/evaluation (NDT/NDE) technique utilized in this research : was ground-coupled ground penetrating rada...

  8. Bridge A0569 : Missouri S&T nondestructive evaluation of bridge decks - pilot study.

    DOT National Transportation Integrated Search

    2014-03-01

    This research has examined the use of nondestructive techniques for concrete bridge deck condition : assessments. The primary nondestructive testing/evaluation (NDT/NDE) technique utilized in this research : was ground-coupled ground penetrating rada...

  9. Bridge K0197 : Missouri S&T nondestructive evaluation of bridge decks - pilot study.

    DOT National Transportation Integrated Search

    2014-03-01

    This research has examined the use of nondestructive techniques for concrete bridge deck condition : assessments. The primary nondestructive testing/evaluation (NDT/NDE) technique utilized in this research : was ground-coupled ground penetrating rada...

  10. Bridge A3017 : Missouri S&T nondestructive evaluation of bridge decks - pilot study.

    DOT National Transportation Integrated Search

    2014-03-01

    This research has examined the use of nondestructive techniques for concrete bridge deck condition : assessments. The primary nondestructive testing/evaluation (NDT/NDE) technique utilized in this research : was ground-coupled ground penetrating rada...

  11. Bridge A3405 : Missouri S&T nondestructive evaluation of bridge decks - pilot study.

    DOT National Transportation Integrated Search

    2014-03-01

    This research has examined the use of nondestructive techniques for concrete bridge deck condition : assessments. The primary nondestructive testing/evaluation (NDT/NDE) technique utilized in this research : was ground-coupled ground penetrating rada...

  12. The application of emulation techniques in the analysis of highly reliable, guidance and control computer systems

    NASA Technical Reports Server (NTRS)

    Migneault, Gerard E.

    1987-01-01

    Emulation techniques can be a solution to a difficulty that arises in the analysis of the reliability of guidance and control computer systems for future commercial aircraft. Described here is the difficulty, the lack of credibility of reliability estimates obtained by analytical modeling techniques. The difficulty is an unavoidable consequence of the following: (1) a reliability requirement so demanding as to make system evaluation by use testing infeasible; (2) a complex system design technique, fault tolerance; (3) system reliability dominated by errors due to flaws in the system definition; and (4) elaborate analytical modeling techniques whose precision outputs are quite sensitive to errors of approximation in their input data. Use of emulation techniques for pseudo-testing systems to evaluate bounds on the parameter values needed for the analytical techniques is then discussed. Finally several examples of the application of emulation techniques are described.

  13. Advanced Platform for Development and Evaluation of Grid Interconnection Systems Using Hardware-in-the-Loop (Poster)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lundstrom, B.; Shirazi, M.; Coddington, M.

    2013-02-01

    This poster describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1TM. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through themore » use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.« less

  14. Advanced Platform for Development and Evaluation of Grid Interconnection Systems Using Hardware-in-the-Loop: Part III - Grid Interconnection System Evaluator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lundstrom, B.; Shirazi, M.; Coddington, M.

    2013-01-01

    This paper describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through themore » use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.« less

  15. Nondestructive Testing Technique to Quantify Deterioration from Marine Borer Attack in Sitka Spruce and Western Hemlock Logs: Observations from a Pilot Test

    Treesearch

    Robert Ross; John W. Forsman; John R. Erickson; Allen M. Brackley

    2014-01-01

    Stress-wave nondestructive evaluation (NDE) techniques are used widely in the forest products industry—from the grading of wood veneer to inspection of timber structures. Inspection professionals frequently use stress-wave NDE techniques to locate internal voids and decayed or deteriorated areas in large timbers. Although these techniques have proven useful, little...

  16. Pulse compression favourable aperiodic infrared imaging approach for non-destructive testing and evaluation of bio-materials

    NASA Astrophysics Data System (ADS)

    Mulaveesala, Ravibabu; Dua, Geetika; Arora, Vanita; Siddiqui, Juned A.; Muniyappa, Amarnath

    2017-05-01

    In recent years, aperiodic, transient pulse compression favourable infrared imaging methodologies demonstrated as reliable, quantitative, remote characterization and evaluation techniques for testing and evaluation of various biomaterials. This present work demonstrates a pulse compression favourable aperiodic thermal wave imaging technique, frequency modulated thermal wave imaging technique for bone diagnostics, especially by considering the bone with tissue, skin and muscle over layers. In order to find the capabilities of the proposed frequency modulated thermal wave imaging technique to detect the density variations in a multi layered skin-fat-muscle-bone structure, finite element modeling and simulation studies have been carried out. Further, frequency and time domain post processing approaches have been adopted on the temporal temperature data in order to improve the detection capabilities of frequency modulated thermal wave imaging.

  17. Free-flight measurement technique in the free-piston high-enthalpy shock tunnel.

    PubMed

    Tanno, H; Komuro, T; Sato, K; Fujita, K; Laurence, S J

    2014-04-01

    A novel multi-component force-measurement technique has been developed and implemented at the impulse facility JAXA-HIEST, in which the test model is completely unrestrained during the test and thus experiences free-flight conditions for a period on the order of milliseconds. Advantages over conventional free-flight techniques include the complete absence of aerodynamic interference from a model support system and less variation in model position and attitude during the test itself. A miniature on-board data recorder, which was a key technology for this technique, was also developed in order to acquire and store the measured data. The technique was demonstrated in a HIEST wind-tunnel test campaign in which three-component aerodynamic force measurement was performed on a blunted cone of length 316 mm, total mass 19.75 kg, and moment of inertia 0.152 kgm(2). During the test campaign, axial force, normal forces, and pitching moment coefficients were obtained at angles of attack from 14° to 32° under two conditions: H0 = 4 MJ/kg, P0 = 14 MPa; and H0 = 16 MJ/kg, P0 = 16 MPa. For the first, low-enthalpy condition, the test flow was considered a perfect gas; measurements were thus directly compared with those obtained in a conventional blow-down wind tunnel (JAXA-HWT2) to evaluate the accuracy of the technique. The second test condition was a high-enthalpy condition in which 85% of the oxygen molecules were expected to be dissociated; high-temperature real-gas effects were therefore evaluated by comparison with results obtained in perfect-gas conditions. The precision of the present measurements was evaluated through an uncertainty analysis, which showed the aerodynamic coefficients in the HIEST low enthalpy test agreeing well with those of JAXA-HWT2. The pitching-moment coefficient, however, showed significant differences between low- and high-enthalpy tests. These differences are thought to result from high-temperature real-gas effects.

  18. Free-flight measurement technique in the free-piston high-enthalpy shock tunnel

    NASA Astrophysics Data System (ADS)

    Tanno, H.; Komuro, T.; Sato, K.; Fujita, K.; Laurence, S. J.

    2014-04-01

    A novel multi-component force-measurement technique has been developed and implemented at the impulse facility JAXA-HIEST, in which the test model is completely unrestrained during the test and thus experiences free-flight conditions for a period on the order of milliseconds. Advantages over conventional free-flight techniques include the complete absence of aerodynamic interference from a model support system and less variation in model position and attitude during the test itself. A miniature on-board data recorder, which was a key technology for this technique, was also developed in order to acquire and store the measured data. The technique was demonstrated in a HIEST wind-tunnel test campaign in which three-component aerodynamic force measurement was performed on a blunted cone of length 316 mm, total mass 19.75 kg, and moment of inertia 0.152 kgm2. During the test campaign, axial force, normal forces, and pitching moment coefficients were obtained at angles of attack from 14° to 32° under two conditions: H0 = 4 MJ/kg, P0 = 14 MPa; and H0 = 16 MJ/kg, P0 = 16 MPa. For the first, low-enthalpy condition, the test flow was considered a perfect gas; measurements were thus directly compared with those obtained in a conventional blow-down wind tunnel (JAXA-HWT2) to evaluate the accuracy of the technique. The second test condition was a high-enthalpy condition in which 85% of the oxygen molecules were expected to be dissociated; high-temperature real-gas effects were therefore evaluated by comparison with results obtained in perfect-gas conditions. The precision of the present measurements was evaluated through an uncertainty analysis, which showed the aerodynamic coefficients in the HIEST low enthalpy test agreeing well with those of JAXA-HWT2. The pitching-moment coefficient, however, showed significant differences between low- and high-enthalpy tests. These differences are thought to result from high-temperature real-gas effects.

  19. Efficient Testing Combining Design of Experiment and Learn-to-Fly Strategies

    NASA Technical Reports Server (NTRS)

    Murphy, Patrick C.; Brandon, Jay M.

    2017-01-01

    Rapid modeling and efficient testing methods are important in a number of aerospace applications. In this study efficient testing strategies were evaluated in a wind tunnel test environment and combined to suggest a promising approach for both ground-based and flight-based experiments. Benefits of using Design of Experiment techniques, well established in scientific, military, and manufacturing applications are evaluated in combination with newly developing methods for global nonlinear modeling. The nonlinear modeling methods, referred to as Learn-to-Fly methods, utilize fuzzy logic and multivariate orthogonal function techniques that have been successfully demonstrated in flight test. The blended approach presented has a focus on experiment design and identifies a sequential testing process with clearly defined completion metrics that produce increased testing efficiency.

  20. Electrical termination techniques

    NASA Technical Reports Server (NTRS)

    Oakey, W. E.; Schleicher, R. R.

    1976-01-01

    A technical review of high reliability electrical terminations for electronic equipment was made. Seven techniques were selected from this review for further investigation, experimental work, and preliminary testing. From the preliminary test results, four techniques were selected for final testing and evaluation. These four were: (1) induction soldering, (2) wire wrap, (3) percussive arc welding, and (4) resistance welding. Of these four, induction soldering was selected as the best technique in terms of minimizing operator errors, controlling temperature and time, minimizing joint contamination, and ultimately producing a reliable, uniform, and reusable electrical termination.

  1. An Approach to the Evaluation of Hypermedia.

    ERIC Educational Resources Information Center

    Knussen, Christina; And Others

    1991-01-01

    Discusses methods that may be applied to the evaluation of hypermedia, based on six models described by Lawton. Techniques described include observation, self-report measures, interviews, automated measures, psychometric tests, checklists and criterion-based techniques, process models, Experimentally Measuring Usability (EMU), and a naturalistic…

  2. Forecasting in foodservice: model development, testing, and evaluation.

    PubMed

    Miller, J L; Thompson, P A; Orabella, M M

    1991-05-01

    This study was designed to develop, test, and evaluate mathematical models appropriate for forecasting menu-item production demand in foodservice. Data were collected from residence and dining hall foodservices at Ohio State University. Objectives of the study were to collect, code, and analyze the data; develop and test models using actual operation data; and compare forecasting results with current methods in use. Customer count was forecast using deseasonalized simple exponential smoothing. Menu-item demand was forecast by multiplying the count forecast by a predicted preference statistic. Forecasting models were evaluated using mean squared error, mean absolute deviation, and mean absolute percentage error techniques. All models were more accurate than current methods. A broad spectrum of forecasting techniques could be used by foodservice managers with access to a personal computer and spread-sheet and database-management software. The findings indicate that mathematical forecasting techniques may be effective in foodservice operations to control costs, increase productivity, and maximize profits.

  3. A Compendium of Assessment Techniques.

    ERIC Educational Resources Information Center

    Knapp, Joan; Sharon, Amiel

    A wide variety of techniques are appropriate for evaluating different types of experiential learning. This monograph includes sections on performance tests, simulations, interviews, ratings, self evaluation, and product assessment. Each section orients the reader to one of these general types of assessment and then provides brief illustrations of…

  4. TECHNIQUES USED IN THE ENVIRONMENTAL ASSESSMENT OF COASTAL WATERS

    EPA Science Inventory

    A variety of laboratory and field assessment techniques are used to evaluate the environmental condition of estuaries. Acute and chronic toxicity tests have been conducted with as many as 25 species to evaluate the effects of surface water and sediment on algae, invertebrates and...

  5. Electrical characterization of a Mapham inverter using pulse testing techniques

    NASA Technical Reports Server (NTRS)

    Baumann, E. D.; Myers, I. T.; Hammond, A. N.

    1990-01-01

    Electric power requirements for aerospace missions have reached megawatt power levels. Within the next few decades, it is anticipated that a manned lunar base, interplanetary travel, and surface exploration of the Martian surface will become reality. Several research and development projects aimed at demonstrating megawatt power level converters for space applications are currently underway at the NASA Lewis Research Center. Innovative testing techniques will be required to evaluate the components and converters, when developed, at their rated power in the absence of costly power sources, loads, and cooling systems. Facilities capable of testing these components and systems at full power are available, but their use may be cost prohibitive. The use of a multiple pulse testing technique is proposed to determine the electrical characteristics of large megawatt level power systems. Characterization of a Mapham inverter is made using the proposed technique and conclusions are drawn concerning its suitability as an experimental tool to evaluate megawatt level power systems.

  6. Preliminary evaluation of several nondestructive-evaluation techniques for silicon nitride gas-turbine rotors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kupperman, D. S.; Sciammarella, C.; Lapinski, N. P.

    1978-01-01

    Several nondestructive-evaluation (NDE) techniques have been examined to establish their effectiveness for detecting critically sized flaws in silicon nitride gas-turbine rotors. Preliminary results have been obtained for holographic interferometry, acoustic microscopy, dye-enhanced radiography, acoustic emission, and acoustic-impact testing techniques. This report discusses the relative effectiveness of these techniques in terms of their applicability to the rotor geometry and ability to detect critically sized flaws. Where feasible, flaw indications were verified by alternative NDE techniques or destructive examination. This study has indicated that, since the various techniques have different advantages, ultimately a reliable interrogation of ceramic rotors may require the applicationmore » of several NDE methods.« less

  7. Testing and characterizations of infrared sensor over the temperature range of 2 Kelvin to 300 Kelvin

    NASA Technical Reports Server (NTRS)

    Hansen, R. G.

    1983-01-01

    Various cryogenic techniques were used to evaluate state of the art electro-optic devices. As research, development, and production demands require more sensitive testing techniques, faster test results, and higher production throughput, the emphasis on supporting cryogenic systems increases. The three traditional methods currently utilized in electro-optic device testing are discussed: (1) liquid contaiment dewars; (2) liquid transfer systems; and (3) closed cycle refrigeration systems. Advantages, disadvantages, and the current state of the art of each of these cryogenic techniques is discussed.

  8. Solid Propellant Test Article (SPTA) Test Stand

    NASA Technical Reports Server (NTRS)

    1991-01-01

    This photograph shows the Solid Propellant Test Article (SPTA) test stand with the Modified Nasa Motor (M-NASA) test article at the Marshall Space Flight Center (MSFC). The SPTA test stand, 12-feet wide by 12-feet long by 24-feet high, was built in 1989 to provide comparative performance data on nozzle and case insulation material and to verify thermostructural analysis models. A modified NASA 48-inch solid motor (M-NASA motor) with a 12-foot blast tube and 10-inch throat makes up the SPTA. The M-NASA motor is being used to evaluate solid rocket motor internal non-asbestos insulation materials, nozzle designs, materials, and new inspection techniques. New internal motor case instrumentation techniques are also being evaluated.

  9. A new technique for measuring listening and reading literacy in developing countries

    NASA Astrophysics Data System (ADS)

    Greene, Barbara A.; Royer, James M.; Anzalone, Stephen

    1990-03-01

    One problem in evaluating educational interventions in developing countries is the absence of tests that adequately reflect the culture and curriculum. The Sentence Verification Technique is a new procedure for measuring reading and listening comprehension that allows for the development of tests based on materials indigenous to a given culture. The validity of using the Sentence Verification Technique to measure reading comprehension in Grenada was evaluated in the present study. The study involved 786 students at standards 3, 4 and 5. The tests for each standard consisted of passages that varied in difficulty. The students identified as high ability students in all three standards performed better than those identified as low ability. All students performed better with easier passages. Additionally, students in higher standards performed bettter than students in lower standards on a given passage. These results supported the claim that the Sentence Verification Technique is a valid measure of reading comprehension in Grenada.

  10. Autonomic Evaluation of Patients With Gastroparesis and Neurostimulation: Comparisons of Direct/Systemic and Indirect/Cardiac Measures

    PubMed Central

    Stocker, Abigail; Abell, Thomas L.; Rashed, Hani; Kedar, Archana; Boatright, Ben; Chen, Jiande

    2016-01-01

    Background Disorders of nausea, vomiting, abdominal pain, and related problems often are manifestations of gastrointestinal, neuromuscular, and/or autonomic dysfunction. Many of these patients respond to neurostimulation, either gastric electrical stimulation or electroacupuncture. Both of these therapeutic techniques appear to influence the autonomic nervous system which can be evaluated directly by traditional testing and indirectly by heart rate variability. Methods We studied patients undergoing gastric neuromodulation by both systemic autonomic testing (39 patients, six males and 33 females, mean age 38 years) and systemic autonomic testing and heart rate variability (35 patients, seven males and 28 females, mean age 37 years) testing before and after gastric neuromodulation. We also performed a pilot study using both systemic autonomic testing and heart rate variability in a small number of patients (five patients, all females, mean age 48.6 years) with diabetic gastroparesis at baseline to compare the two techniques at baseline. Systemic autonomic testing and heart rate variability were performed with standardized techniques and gastric electrical stimulation was performed as previously described with electrodes implanted serosally in the myenteric plexus. Results Both systemic autonomic testing and heart rate variability measures were often abnormal at baseline and showed changes after gastric neuromodulation therapy in two groups of symptomatic patients. Pilot data on a small group of similar patients with systemic automatic nervous measures and heart rate variability showed good concordance between the two techniques. Conclusions Both traditional direct autonomic measures and indirect measures such as heart rate variability were evaluated, including a pilot study of both methods in the same patient group. Both appear to be useful in evaluation of patients at baseline and after stimulation therapies; however, a future full head-to-head comparison is warranted. PMID:27785318

  11. High temperature tensile testing of ceramic composites

    NASA Technical Reports Server (NTRS)

    Gyekenyesi, John Z.; Hemann, John H.

    1988-01-01

    The various components of a high temperature tensile testing system are evaluated. The objective is the high temperature tensile testing of SiC fiber reinforced reaction bonded Si3N4 specimens at test temperatures up to 1650 C (3000 F). Testing is to be conducted in inert gases and air. Gripping fixtures, specimen configurations, furnaces, optical strain measuring systems, and temperature measurement techniques are reviewed. Advantages and disadvantages of the various techniques are also noted.

  12. TECHNIQUES USED IN THE ENVIRONMENTAL ASSESSMENT OF NEAR-COASTAL AREAS

    EPA Science Inventory

    A variety of laboratory and field assessment techniques are used to evaluate the environmental condition of estuaries. Acute and chronic toxicity tests have been conducted with as many as 25 species to evaluate the effects of water and sediment on algae, invertebrates and fish. E...

  13. Imprisoned Resources--Innovative Techniques in Educating Prison Inmates.

    ERIC Educational Resources Information Center

    Wood, Larry F.; Jenkins, William O.

    The effectiveness of employing educationally advanced inmates as one-to-one basic education tutors for inmate students was evaluated. In conjunction with this evaluation, an experimental study of the most efficient material presentation and testing techniques using this manpower resource was conducted. Three different modes of presenting…

  14. In-place cement stabilized base reconstruction techniques interim report, "construction and two year evaluation" : technical summary.

    DOT National Transportation Integrated Search

    2002-08-01

    The purpose of this research is to evaluate the effectiveness of soil cement shrinkage crack mitigation techniques. Ten test sections, 1000 feet long, were constructed on LA 89 in Vermilion Parish. The shrinkage crack mitigation methods being evaluat...

  15. Evaluation of various thrust calculation techniques on an F404 engine

    NASA Technical Reports Server (NTRS)

    Ray, Ronald J.

    1990-01-01

    In support of performance testing of the X-29A aircraft at the NASA-Ames, various thrust calculation techniques were developed and evaluated for use on the F404-GE-400 engine. The engine was thrust calibrated at NASA-Lewis. Results from these tests were used to correct the manufacturer's in-flight thrust program to more accurately calculate thrust for the specific test engine. Data from these tests were also used to develop an independent, simplified thrust calculation technique for real-time thrust calculation. Comparisons were also made to thrust values predicted by the engine specification model. Results indicate uninstalled gross thrust accuracies on the order of 1 to 4 percent for the various in-flight thrust methods. The various thrust calculations are described and their usage, uncertainty, and measured accuracies are explained. In addition, the advantages of a real-time thrust algorithm for flight test use and the importance of an accurate thrust calculation to the aircraft performance analysis are described. Finally, actual data obtained from flight test are presented.

  16. 30 CFR 282.28 - Environmental protection measures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... recent research or improved monitoring techniques. (5) When prototype test mining is proposed, the lessee...) The sampling techniques and procedures to be used to acquire the needed data and information; (ii) The... evaluation of the approved Delineation, Testing, or Mining Plan. The Director's review of the air quality...

  17. Evaluation of three techniques for classifying urban land cover patterns using LANDSAT MSS data. [New Orleans, Louisiana

    NASA Technical Reports Server (NTRS)

    Baumann, P. R. (Principal Investigator)

    1979-01-01

    Three computer quantitative techniques for determining urban land cover patterns are evaluated. The techniques examined deal with the selection of training samples by an automated process, the overlaying of two scenes from different seasons of the year, and the use of individual pixels as training points. Evaluation is based on the number and type of land cover classes generated and the marks obtained from an accuracy test. New Orleans, Louisiana and its environs form the study area.

  18. Field Calibration of Wind Direction Sensor to the True North and Its Application to the Daegwanryung Wind Turbine Test Sites

    PubMed Central

    Lee, Jeong Wan

    2008-01-01

    This paper proposes a field calibration technique for aligning a wind direction sensor to the true north. The proposed technique uses the synchronized measurements of captured images by a camera, and the output voltage of a wind direction sensor. The true wind direction was evaluated through image processing techniques using the captured picture of the sensor with the least square sense. Then, the evaluated true value was compared with the measured output voltage of the sensor. This technique solves the discordance problem of the wind direction sensor in the process of installing meteorological mast. For this proposed technique, some uncertainty analyses are presented and the calibration accuracy is discussed. Finally, the proposed technique was applied to the real meteorological mast at the Daegwanryung test site, and the statistical analysis of the experimental testing estimated the values of stable misalignment and uncertainty level. In a strict sense, it is confirmed that the error range of the misalignment from the exact north could be expected to decrease within the credibility level. PMID:27873957

  19. Evaluating Trauma Sonography for Operational Use in the Microgravity Environment

    NASA Technical Reports Server (NTRS)

    Kirkpatrick, Andrew W.; Jones, Jeffrey A.; Sargsyan, Ashot; Hamilton, Douglas; Melton, Shannon; Beck, George; Nicolaou, Savvas; Campbell, Mark; Dulchavsky, Scott

    2007-01-01

    Sonography is the only medical imaging modality aboard the ISS, and is likely to remain the leading imaging modality in future human space flight programs. While trauma sonography (TS) has been well recognized for terrestrial trauma settings, the technique had to be evaluated for suitability in space flight prior to adopting it as an operational capability. The authors found the following four-phased evaluative approach applicable to this task: 1) identifying standard or novel terrestrial techniques for potential use in space medicine; 2) developing and testing these techniques with suggested modifications on the ground (1g) either in clinical settings or in animal models, as appropriate; 3) evaluating and refining the techniques in parabolic flight (0g); and 4) validating and implementing for clinical use in space. In Phase I of the TS project, expert opinion and literature review suggested TS to be a potential screening tool for trauma in space. In Phase II, animal models were developed and tested in ground studies, and clinical studies were carried out in collaborating trauma centers. In Phase III, animal models were flight-tested in the NASA KC-135 Reduced Gravity Laboratory. Preliminary results of the first three phases demonstrated potential clinical utility of TS in microgravity. Phase IV studies have begun to address crew training issues, on-board imaging protocols, and data transfer procedures necessary to offer the modified TS technique for space use.

  20. Moving Target Techniques: Leveraging Uncertainty for CyberDefense

    DTIC Science & Technology

    2015-12-15

    cyberattacks is a continual struggle for system managers. Attackers often need only find one vulnerability (a flaw or bug that an attacker can exploit...additional parsing code itself could have security-relevant software bugs . Dynamic  Network   Techniques in the dynamic network domain change the...evaluation of MT techniques can benefit from a variety of evaluation approaches, including abstract analysis, modeling and simulation, test bed

  1. Molecular Modeling in Drug Design for the Development of Organophosphorus Antidotes/Prophylactics.

    DTIC Science & Technology

    1986-06-01

    multidimensional statistical QSAR analysis techniques to suggest new structures for synthesis and evaluation. C. Application of quantum chemical techniques to...compounds for synthesis and testing for antidotal potency. E. Use of computer-assisted methods to determine the steric constraints at the active site...modeling techniques to model the enzyme acetylcholinester-se. H. Suggestion of some novel compounds for synthesis and testing for reactivating

  2. A unique control system simulator for the evaluation of pulsed plasma thrusters

    NASA Technical Reports Server (NTRS)

    Dahlgren, J. B.

    1973-01-01

    Because of the low thrust characteristics of solid-propellant pulsed plasma thrusters and their operational requirement to operate in a vacuum environment, unique and sensitive test techniques are required. A technique evolved for testing and evaluating pulsed plasma thrusters in an open- or closed-loop system mode employs a unique air bearing platform as a single-axis simulator on which the thruster is mounted. The simulator described was developed to evaluate pulsed plasma thrusters in the low micropound range; however, the simulator can be extended to cover the operational range of currently developed millipound thrusters.

  3. Usability evaluation techniques in mobile commerce applications: A systematic review

    NASA Astrophysics Data System (ADS)

    Hussain, Azham; Mkpojiogu, Emmanuel O. C.

    2016-08-01

    Obviously, there are a number of literatures concerning the usability of mobile commerce (m-commerce) applications and related areas, but they do not adequately provide knowledge about usability techniques used in most of the empirical usability evaluation for m-commerce application. Therefore, this paper is aimed at producing the usability techniques frequently used in the aspect of usability evaluation for m-commerce applications. To achieve the stated objective, systematic literature review was employed. Sixty seven papers were downloaded in usability evaluation for m-commerce and related areas; twenty one most relevant studies were selected for review in order to extract the appropriate information. The results from the review shows that heuristic evaluation, formal test and think aloud methods are the most commonly used methods in m-commerce application in comparison to cognitive walkthrough and the informal test methods. Moreover, most of the studies applied control experiment (33.3% of the total studies); other studies that applied case study for usability evaluation are 14.28%. The results from this paper provide additional knowledge to the usability practitioners and research community for the current state and use of usability techniques in m-commerce application.

  4. Accelerated test techniques for micro-circuits: Evaluation of high temperature (473 k - 573 K) accelerated life test techniques as effective microcircuit screening methods

    NASA Technical Reports Server (NTRS)

    Johnson, G. M.

    1976-01-01

    The application of high temperature accelerated test techniques was shown to be an effective method of microcircuit defect screening. Comprehensive microcircuit evaluations and a series of high temperature (473 K to 573 K) life tests demonstrated that a freak or early failure population of surface contaminated devices could be completely screened in thirty two hours of test at an ambient temperature of 523 K. Equivalent screening at 398 K, as prescribed by current Military and NASA specifications, would have required in excess of 1,500 hours of test. All testing was accomplished with a Texas Instruments' 54L10, low power triple-3 input NAND gate manufactured with a titanium- tungsten (Ti-W), Gold (Au) metallization system. A number of design and/or manufacturing anomalies were also noted with the Ti-W, Au metallization system. Further study of the exact nature and cause(s) of these anomalies is recommended prior to the use of microcircuits with Ti-W, Au metallization in long life/high reliability applications. Photomicrographs of tested circuits are included.

  5. Mapping chemicals in air using an environmental CAT scanning system: evaluation of algorithms

    NASA Astrophysics Data System (ADS)

    Samanta, A.; Todd, L. A.

    A new technique is being developed which creates near real-time maps of chemical concentrations in air for environmental and occupational environmental applications. This technique, we call Environmental CAT Scanning, combines the real-time measuring technique of open-path Fourier transform infrared spectroscopy with the mapping capabilitites of computed tomography to produce two-dimensional concentration maps. With this system, a network of open-path measurements is obtained over an area; measurements are then processed using a tomographic algorithm to reconstruct the concentrations. This research focussed on the process of evaluating and selecting appropriate reconstruction algorithms, for use in the field, by using test concentration data from both computer simultation and laboratory chamber studies. Four algorithms were tested using three types of data: (1) experimental open-path data from studies that used a prototype opne-path Fourier transform/computed tomography system in an exposure chamber; (2) synthetic open-path data generated from maps created by kriging point samples taken in the chamber studies (in 1), and; (3) synthetic open-path data generated using a chemical dispersion model to create time seires maps. The iterative algorithms used to reconstruct the concentration data were: Algebraic Reconstruction Technique without Weights (ART1), Algebraic Reconstruction Technique with Weights (ARTW), Maximum Likelihood with Expectation Maximization (MLEM) and Multiplicative Algebraic Reconstruction Technique (MART). Maps were evaluated quantitatively and qualitatively. In general, MART and MLEM performed best, followed by ARTW and ART1. However, algorithm performance varied under different contaminant scenarios. This study showed the importance of using a variety of maps, particulary those generated using dispersion models. The time series maps provided a more rigorous test of the algorithms and allowed distinctions to be made among the algorithms. A comprehensive evaluation of algorithms, for the environmental application of tomography, requires the use of a battery of test concentration data before field implementation, which models reality and tests the limits of the algorithms.

  6. Optimizing Department of Defense Acquisition Development Test and Evaluation Scheduling

    DTIC Science & Technology

    2015-06-01

    CPM Critical Path Method DOD Department of Defense DT&E development test and evaluation EMD engineering and manufacturing development GAMS...these, including the Program Evaluation Review Technique (PERT), the Critical Path Method ( CPM ), and the resource- constrained project-scheduling...problem (RCPSP). These are of particular interest to this thesis as the current scheduling method uses elements of the PERT/ CPM , and the test

  7. Fit Analysis of Different Framework Fabrication Techniques for Implant-Supported Partial Prostheses.

    PubMed

    Spazzin, Aloísio Oro; Bacchi, Atais; Trevisani, Alexandre; Farina, Ana Paula; Dos Santos, Mateus Bertolini

    2016-01-01

    This study evaluated the vertical misfit of implant-supported frameworks made using different techniques to obtain passive fit. Thirty three-unit fixed partial dentures were fabricated in cobalt-chromium alloy (n = 10) using three fabrication methods: one-piece casting, framework cemented on prepared abutments, and laser welding. The vertical misfit between the frameworks and the abutments was evaluated with an optical microscope using the single-screw test. Data were analyzed using one-way analysis of variance and Tukey test (α = .05). The one-piece casted frameworks presented significantly higher vertical misfit values than those found for framework cemented on prepared abutments and laser welding techniques (P < .001 and P < .003, respectively). Laser welding and framework cemented on prepared abutments are effective techniques to improve the adaptation of three-unit implant-supported prostheses. These techniques presented similar fit.

  8. Rapid Model Fabrication and Testing for Aerospace Vehicles

    NASA Technical Reports Server (NTRS)

    Buck, Gregory M.

    2000-01-01

    Advanced methods for rapid fabrication and instrumentation of hypersonic wind tunnel models are being developed and evaluated at NASA Langley Research Center. Rapid aeroheating model fabrication and measurement techniques using investment casting of ceramic test models and thermographic phosphors are reviewed. More accurate model casting techniques for fabrication of benchmark metal and ceramic test models are being developed using a combination of rapid prototype patterns and investment casting. White light optical scanning is used for coordinate measurements to evaluate the fabrication process and verify model accuracy to +/- 0.002 inches. Higher-temperature (<210C) luminescent coatings are also being developed for simultaneous pressure and temperature mapping, providing global pressure as well as global aeroheating measurements. Together these techniques will provide a more rapid and complete experimental aerodynamic and aerothermodynamic database for future aerospace vehicles.

  9. Evaluation of AISI 4140 Steel Repair Without Post-Weld Heat Treatment

    NASA Astrophysics Data System (ADS)

    Silva, Cleiton C.; de Albuquerque, Victor H. C.; Moura, Cícero R. O.; Aguiar, Willys M.; Farias, Jesualdo P.

    2009-04-01

    The present work evaluates the two-layer technique on the heat affected zone (HAZ) of AISI 4140 steel welded with different heat input levels between the first and second layer. The weld heat input levels selected by the Higuchi test were 5/5, 5/10, and 15/5 kJ/cm. The evaluation of the refining and/or tempering of the coarsened grain HAZ of the first layer was carried out using metallographic tests, microhardness measurements, and the Charpy-V impact test. The tempering of the first layer was only reached when the weld heat input ratio was 5/5 kJ/cm. The results of the Charpy-V impact test showed that the two-layer technique was efficient, from the point of view of toughness, since the toughness values reached were greater than the base metal for all weld heat input ratios applied. The results obtained indicate that the best performance of the two-layer deposition technique was for the weld heat input ratio 5/5 kJ/cm employing low heat input.

  10. Measurement techniques and instruments suitable for life-prediction testing of photovoltaic arrays

    NASA Technical Reports Server (NTRS)

    Noel, G. T.; Sliemers, F. A.; Deringer, G. C.; Wood, V. E.; Wilkes, K. E.; Gaines, G. B.; Carmichael, D. C.

    1978-01-01

    Array failure modes, relevant materials property changes, and primary degradation mechanisms are discussed as a prerequisite to identifying suitable measurement techniques and instruments. Candidate techniques and instruments are identified on the basis of extensive reviews of published and unpublished information. These methods are organized in six measurement categories - chemical, electrical, optical, thermal, mechanical, and other physicals. Using specified evaluation criteria, the most promising techniques and instruments for use in life prediction tests of arrays were selected.

  11. Space Shuttle Projects

    NASA Image and Video Library

    1991-07-01

    This photograph shows the Solid Propellant Test Article (SPTA) test stand with the Modified Nasa Motor (M-NASA) test article at the Marshall Space Flight Center (MSFC). The SPTA test stand, 12-feet wide by 12-feet long by 24-feet high, was built in 1989 to provide comparative performance data on nozzle and case insulation material and to verify thermostructural analysis models. A modified NASA 48-inch solid motor (M-NASA motor) with a 12-foot blast tube and 10-inch throat makes up the SPTA. The M-NASA motor is being used to evaluate solid rocket motor internal non-asbestos insulation materials, nozzle designs, materials, and new inspection techniques. New internal motor case instrumentation techniques are also being evaluated.

  12. Nondestructive Methods and Special Test Instrumentation Supporting NASA Composite Overwrapped Pressure Vessel Assessments

    NASA Technical Reports Server (NTRS)

    Saulsberry, Regor; Greene, Nathanael; Cameron, Ken; Madaras, Eric; Grimes-Ledesma, Lorie; Thesken, John; Phoenix, Leigh; Murthy, Pappu; Revilock, Duane

    2007-01-01

    Many aging composite overwrapped pressure vessels (COPVs), being used by the National Aeronautics and Space Administration (NASA) are currently under evaluation to better quantify their reliability and clarify their likelihood of failure due to stress rupture and age-dependent issues. As a result, some test and analysis programs have been successfully accomplished and other related programs are still in progress at the NASA Johnson Space Center (JSC) White Sands Test Facility (WSTF) and other NASA centers, with assistance from the commercial sector. To support this effort, a group of Nondestructive Evaluation (NDE) experts was assembled to provide NDE competence for pretest evaluation of test articles and for application of NDE technology to real-time testing. Techniques were required to provide assurance that the test article had adequate structural integrity and manufacturing consistency to be considered acceptable for testing and these techniques were successfully applied. Destructive testing is also being accomplished to better understand the physical and chemical property changes associated with progression toward "stress rupture" (SR) failure, and it is being associated with NDE response, so it can potentially be used to help with life prediction. Destructive work also includes the evaluation of residual stresses during dissection of the overwrap, laboratory evaluation of specimens extracted from the overwrap to evaluate physical property changes, and quantitative microscopy to inform the theoretical micromechanics.

  13. Transverse vibration technique to identify deteriorated wood floor systems

    Treesearch

    R.J. Ross; X. Wang; M.O. Hunt; L.A. Soltis

    2002-01-01

    The Forest Products Laboratory, USDA Forest Service, has been developing nondestructive evaluation (NDE) techniques to identify degradation of wood in structures and the performance characteristics that remain in the structure. This work has focused on using dynamic testing techniques, particularly stress wave and ultrasonic transmission NDE techniques for both...

  14. Reliability of clinical diagnosis and laboratory testing techniques currently used for identification of canine parvovirus enteritis in clinical settings

    PubMed Central

    FAZ, Mirna; MARTÍNEZ, José Simón; QUIJANO-HERNÁNDEZ, Israel; FAJARDO, Raúl

    2016-01-01

    Canine parvovirus type 2 (CPV-2) is the main etiological agent of viral enteritis in dogs. Actually in literature, CPV-2 has been reported with clinical signs that vary from the classical disease, and immunochromatography test and PCR technique have been introduced to veterinary hospitals to confirm CPV-2 diagnosis and other infections. However, the reliability of these techniques has been poorly analyzed. In this study, we evaluated the sensitivity and specificity of veterinary clinical diagnosis, immunochromatography test and PCR technique. Our data indicate that variations in the clinical signs of CPV-2 complicate the gathering of an appropriate diagnosis; and immunochromatography test and PCR technique do not have adequate sensitivity to diagnose positive cases. PMID:27818461

  15. Evaluation of New Repair Methods for Seal Surface Defects on Reusable Solid Rocket Motor (RSRM) Hardware

    NASA Technical Reports Server (NTRS)

    Stanley, Stephanie; Selvidge, Shawn

    2003-01-01

    The focus of the evaluation was to develop a back-up method to cell plating for the improvement or repair of seal surface defects within D6-AC steel and 7075-T73 aluminum used in the RSRM program. Several techniques were investigated including thermal and non-thermal based techniques. Ideally the repair would maintain the inherent properties of the substrate without losing integrity at the repair site. The repaired sites were tested for adhesion, corrosion, hardness, microhardness, surface toughness, thermal stability, ability to withstand bending of the repair site, and the ability to endure a high-pressure water blast without compromising the repaired site. The repaired material could not change the inherent properties of the substrate throughout each of the test in order to remain a possible technique to repair the RSRM substrate materials. One repair method, Electro-Spark Alloying, passed all the testing and is considered a candidate for further evaluation.

  16. Evaluation of New Repair Methods for Seal Surface Defects on Reusable Solid Rocket Motor (RSRM) Hardware

    NASA Technical Reports Server (NTRS)

    Stanley, Stephanie D.; Selvidge, Shawn A.; Cash, Steve (Technical Monitor)

    2002-01-01

    The focus of the evaluation was to develop a back-up method to cell plating for the improvement or repair of seal surface defects within D6-AC steel and 7075-T73 aluminum used in the RSRM program. Several techniques were investigated including thermal and non-thermal based techniques. Ideally the repair would maintain the inherent properties of the substrate without losing integrity at the repair site. The repaired sites were tested for adhesion, corrosion, hardness, microhardness, surface toughness, thermal stability, ability to withstand bending of the repair site, and the ability to endure a high-pressure water blast without compromising the repaired site. The repaired material could not change the inherent properties of the substrate throughout each of the test in order to remain a possible technique to repair the RSRM substrate materials. One repair method, Electro-Spark Alloying, passed all the testing and is considered a candidate for further evaluation.

  17. New International Program to Asses the Reliability of Emerging Nondestructive Techniques (PARENT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Prokofiev, Iouri; Cumblidge, Stephen E.; Csontos, Aladar A.

    2013-01-25

    The Nuclear Regulatory Commission (NRC) established the Program to Assess the Reliability of Emerging Nondestructive Techniques (PARENT) to follow on from the successful Program for the Inspection of Nickel alloy Components (PINC). The goal of the PARENT is to conduct a confirmatory assessment of the reliability of nondestructive evaluation (NDE) techniques for detecting and sizing primary water stress corrosion cracks (PWSCC) and applying the lessons learned from PINC to a series of round-robin tests. These open and blind round-robin tests will comprise a new set of typical pressure boundary components including dissimilar metal welds (DMWs) and bottom-mounted instrumentation penetrations. Openmore » round-robin tests will engage research and industry teams worldwide to investigate and demonstrate the reliability of emerging NDE techniques to detect and size flaws with a wide range of lengths, depths, orientations, and locations. Blind round-robin tests will utilize various testing organizations, whose inspectors and procedures are certified by the standards for the nuclear industry in their respective countries, to investigate the ability of established NDE techniques to detect and size flaws whose characteristics range from relatively easy to very difficult for detection and sizing. Blind and open round-robin testing started in late 2011 and early 2012, respectively. This paper will present the work scope with reports on progress, NDE methods evaluated, and project timeline for PARENT.« less

  18. Evaluation performance of diagnostic methods of intestinal parasitosis in school age children in Ethiopia.

    PubMed

    Yimer, Mulat; Hailu, Tadesse; Mulu, Wondemagegn; Abera, Bayeh

    2015-12-26

    Although the sensitivity of Wet mount technique is questionable, it is the major diagnostic technique for routine diagnosis of intestinal parasitosis in Ethiopia. Therefore, the aim of this study was the evaluation performance of diagnostic methods of intestinal parasitosis in school age children in Ethiopia. A cross sectional study was conducted from May to June 2013. Single stool sample was processed for direct, Formol ether concentration (FEC) and Kato Katz methods. The sensitivity and negative predictive value (NPV) of diagnostic tests were calculated in terms of the "Gold" standard method (the combined result of the three methods altogether). A total of 422 school age children were participated in this study. The prevalence of intestinal parasites was high (74.6%) with Kato Katz technique. The sensitivity of Wet mount, FEC and Kato Katz tests against the Gold standard test was 48.9, 63.1 and 93.7%, respectively. Kato Katz technique revealed a better NPV 80.4 (80.1-80.6) as compared to the Wet mount (33.7%) and FEC techniques (41.3%). In this study, the Kato Katz technique outperformed the other two methods but the true values for sensitivity, specificity and diagnostic values are not known. Moreover, it is labor intensive and not easily accessible. Hence, it is preferable to use FEC technique to complement the Wet mount test.

  19. Nondestructive evaluation of green wood using stress wave and transverse vibration techniques

    Treesearch

    Udaya B. Halabe; Gangadhar M. Bidigalu; Hota V.S. GangaRao; Robert J. Ross

    1997-01-01

    Longitudinal stress wave and transverse vibration nondestructive testing (NDT) techniques have proven to be accurate means of evaluating the quality of wood based products. Researchers have found strong relationships between stress wave and transverse vibration parameters (e.g., wave velocity and modulus of elasticity predicted using NDT measurements) with the actual...

  20. Statistical Tests of Reliability of NDE

    NASA Technical Reports Server (NTRS)

    Baaklini, George Y.; Klima, Stanley J.; Roth, Don J.; Kiser, James D.

    1987-01-01

    Capabilities of advanced material-testing techniques analyzed. Collection of four reports illustrates statistical method for characterizing flaw-detecting capabilities of sophisticated nondestructive evaluation (NDE). Method used to determine reliability of several state-of-the-art NDE techniques for detecting failure-causing flaws in advanced ceramic materials considered for use in automobiles, airplanes, and space vehicles.

  1. Technologies of Student Testing for Learning Quality Evaluation in the System of Higher Education

    ERIC Educational Resources Information Center

    Bayukova, Nadezhda Olegovna; Kareva, Ludmila Alexandrovna; Rudometova, Liliya Tarasovna; Shlangman, Marina Konstantinovna; Yarantseva, Natalia Vladislavovna

    2015-01-01

    The paper deals with technology of students' achievement in the area of educational activities, methods, techniques, forms and conditions of monitoring knowledge quality in accordance with the requirements of Russian higher education system modernization. The authors propose methodic techniques of students' training for testing based on innovative…

  2. Aerodynamic force measurement on a large-scale model in a short duration test facility

    NASA Astrophysics Data System (ADS)

    Tanno, H.; Kodera, M.; Komuro, T.; Sato, K.; Takahasi, M.; Itoh, K.

    2005-03-01

    A force measurement technique has been developed for large-scale aerodynamic models with a short test time. The technique is based on direct acceleration measurements, with miniature accelerometers mounted on a test model suspended by wires. Measuring acceleration at two different locations, the technique can eliminate oscillations from natural vibration of the model. The technique was used for drag force measurements on a 3m long supersonic combustor model in the HIEST free-piston driven shock tunnel. A time resolution of 350μs is guaranteed during measurements, whose resolution is enough for ms order test time in HIEST. To evaluate measurement reliability and accuracy, measured values were compared with results from a three-dimensional Navier-Stokes numerical simulation. The difference between measured values and numerical simulation values was less than 5%. We conclude that this measurement technique is sufficiently reliable for measuring aerodynamic force within test durations of 1ms.

  3. Radionuclide observables during the Integrated Field Exercise of the Comprehensive Nuclear-Test-Ban Treaty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burnett, Jonathan L.; Miley, Harry S.; Milbrath, Brian D.

    In 2014 the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) undertook the Integrated Field Exercise (IFE) in Jordan. The exercise consisted of a simulated 0.5 – 2 kT underground explosion triggering an On-site Inspection (OSI) to search for evidence of a Treaty violation. This research evaluates two of the OSI techniques, including laboratory-based gamma-spectrometry of soil samples and in situ gamma-spectrometry for 17 particulate radionuclides indicative of nuclear weapon tests. The detection sensitivity is evaluated using real IFE and model data. It indicates that higher sensitivity laboratory measurements are the optimum technique during the IFE and OSI timeframes.

  4. "Ehrr ... What's Up Doc?": Using Cartoon Tests To Evaluate Educational Drama Programmes.

    ERIC Educational Resources Information Center

    Pearce, Glenn

    2003-01-01

    Discusses how a projective technique known as "cartoon tests" can be used by drama educators for programme evaluation and for learning-needs analysis and monitoring. Provides findings in which cartoon tests were used as one of several methods to explore student perceptions of a drama-based marketing subject at an Australian university.…

  5. Double row equivalent for rotator cuff repair: A biomechanical analysis of a new technique.

    PubMed

    Robinson, Sean; Krigbaum, Henry; Kramer, Jon; Purviance, Connor; Parrish, Robin; Donahue, Joseph

    2018-06-01

    There are numerous configurations of double row fixation for rotator cuff tears however, there remains to be a consensus on the best method. In this study, we evaluated three different double-row configurations, including a new method. Our primary question is whether the new anchor and technique compares in biomechanical strength to standard double row techniques. Eighteen prepared fresh frozen bovine infraspinatus tendons were randomized to one of three groups including the New Double Row Equivalent, Arthrex Speedbridge and a transosseous equivalent using standard Stabilynx anchors. Biomechanical testing was performed on humeri sawbones and ultimate load, strain, yield strength, contact area, contact pressure, and a survival plots were evaluated. The new double row equivalent method demonstrated increased survival as well as ultimate strength at 415N compared to the remainder testing groups as well as equivalent contact area and pressure to standard double row techniques. This new anchor system and technique demonstrated higher survival rates and loads to failure than standard double row techniques. This data provides us with a new method of rotator cuff fixation which should be further evaluated in the clinical setting. Basic science biomechanical study.

  6. Development and evaluation of the impulse transfer function technique

    NASA Technical Reports Server (NTRS)

    Mantus, M.

    1972-01-01

    The development of the test/analysis technique known as the impulse transfer function (ITF) method is discussed. This technique, when implemented with proper data processing systems, should become a valuable supplement to conventional dynamic testing and analysis procedures that will be used in the space shuttle development program. The method can relieve many of the problems associated with extensive and costly testing of the shuttle for transient loading conditions. In addition, the time history information derived from impulse testing has the potential for being used to determine modal data for the structure under investigation. The technique could be very useful in determining the time-varying modal characteristics of structures subjected to thermal transients, where conventional mode surveys are difficult to perform.

  7. Rasch Analysis for Instrument Development: Why, When, and How?

    ERIC Educational Resources Information Center

    Boone, William J.

    2016-01-01

    This essay describes Rasch analysis psychometric techniques and how such techniques can be used by life sciences education researchers to guide the development and use of surveys and tests. Specifically, Rasch techniques can be used to document and evaluate the measurement functioning of such instruments. Rasch techniques also allow researchers to…

  8. Falsification Testing of Instrumental Variables Methods for Comparative Effectiveness Research.

    PubMed

    Pizer, Steven D

    2016-04-01

    To demonstrate how falsification tests can be used to evaluate instrumental variables methods applicable to a wide variety of comparative effectiveness research questions. Brief conceptual review of instrumental variables and falsification testing principles and techniques accompanied by an empirical application. Sample STATA code related to the empirical application is provided in the Appendix. Comparative long-term risks of sulfonylureas and thiazolidinediones for management of type 2 diabetes. Outcomes include mortality and hospitalization for an ambulatory care-sensitive condition. Prescribing pattern variations are used as instrumental variables. Falsification testing is an easily computed and powerful way to evaluate the validity of the key assumption underlying instrumental variables analysis. If falsification tests are used, instrumental variables techniques can help answer a multitude of important clinical questions. © Health Research and Educational Trust.

  9. Ground penetrating radar evaluation and implementation.

    DOT National Transportation Integrated Search

    2014-07-01

    Six commercial ground penetrating radar (GPR) : systems were evaluated to determine the state-of-the-art of GPR technologies for railroad track : substructure inspection. : Phase 1 evaluated GPR ballast inspection : techniques by performing testing a...

  10. Damage source identification of reinforced concrete structure using acoustic emission technique.

    PubMed

    Panjsetooni, Alireza; Bunnori, Norazura Muhamad; Vakili, Amir Hossein

    2013-01-01

    Acoustic emission (AE) technique is one of the nondestructive evaluation (NDE) techniques that have been considered as the prime candidate for structural health and damage monitoring in loaded structures. This technique was employed for investigation process of damage in reinforced concrete (RC) frame specimens. A number of reinforced concrete RC frames were tested under loading cycle and were simultaneously monitored using AE. The AE test data were analyzed using the AE source location analysis method. The results showed that AE technique is suitable to identify the sources location of damage in RC structures.

  11. Damage Source Identification of Reinforced Concrete Structure Using Acoustic Emission Technique

    PubMed Central

    Panjsetooni, Alireza; Bunnori, Norazura Muhamad; Vakili, Amir Hossein

    2013-01-01

    Acoustic emission (AE) technique is one of the nondestructive evaluation (NDE) techniques that have been considered as the prime candidate for structural health and damage monitoring in loaded structures. This technique was employed for investigation process of damage in reinforced concrete (RC) frame specimens. A number of reinforced concrete RC frames were tested under loading cycle and were simultaneously monitored using AE. The AE test data were analyzed using the AE source location analysis method. The results showed that AE technique is suitable to identify the sources location of damage in RC structures. PMID:23997681

  12. AGARD Flight Test Techniques Series. Volume 8. Flight Testing under Extreme Environmental Conditions

    DTIC Science & Technology

    1988-01-01

    gravity control system operation. The overall objective of fuel system tests is to determine whether the system functions properly at all conditions both... gravity . 3.3.4 Hydraulic System The functional adequacy of the hydraulic system should be evaluated by monitoring operating system temperatures and...mechanical or gravity function of the crew ladder should be evaluated. The ladder should be exposed to freasing rain and icing to evaluate the non

  13. Novel integrated nondestructive testing methodology for detection and evaluation of corrosion in cement-based materials.

    DOT National Transportation Integrated Search

    2014-06-01

    The objective of this project focused on the development of a hybrid nondestructive testing and evaluation (NDT&E) methodology that combines the benefits of microwave NDT and thermography into one new technique. In this way, unique features of both N...

  14. Reefs and Learning: Education Evaluation Techniques

    ERIC Educational Resources Information Center

    Stepath, Carl M.

    2006-01-01

    Marine education research designs are discussed, and student learning outcomes while monitoring a coral reef is evaluated. Changes in environmental knowledge and attitudes, ecological intention to act, and direct reef experience were investigated. Differences between student pre-test and the post-test responses were observed, and analysis is…

  15. AGARD Flight Test Techniques Series. Volume 17. Electronic Warfare Test and Evaluation. (Les Essais et l’Evaluation du Materiel de Guerre Electronique)

    DTIC Science & Technology

    2000-03-01

    FRIENDLY DR ENEMY PLOY OFOR DEGSRADING, ENEUTALY IG DEGRA E,’ EUTRALIE, OR DESTR Y concepts, procedures, and techniques that apply generically to CMA...Association of Old Crows, September 1984 Price, Alfred, "The History of Electronic Warfare," Volume 2, Association of Old Crows, October 1989 Claxton, John...Canada Les demandes de documents RTO ou AGARD doivent comporter la denomination "RTO" ou "AGARD" selon le cas, suivie du numdro de s~rie (par exemple

  16. Advanced Platform for Development and Evaluation of Grid Interconnection Systems Using Hardware-in-the-Loop: Part III -- Grid Interconnection System Evaluator: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lundstrom, B.; Shirazi, M.; Coddington, M.

    2013-01-01

    This paper, presented at the IEEE Green Technologies Conference 2013, describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1 (TM). The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to testmore » the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.« less

  17. Fatigue Test Design: Scenarios for Biaxial Fatigue Testing of a 60-Meter Wind Turbine Blade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Post, Nathan

    Current practice in commercial certification of wind turbine blades is to perform separate flap and lead-lag fatigue tests. The National Renewable Energy Laboratory has been researching and evaluating biaxial fatigue testing techniques and demonstrating various options, typically on smaller-scale test articles at the National Wind Technology Center. This report evaluates some of these biaxial fatigue options in the context of application to a multimegawatt blade certification test program at the Wind Technology Testing Center in Charlestown, Massachusetts.

  18. Development and evaluation of an automatic labeling technique for spring small grains

    NASA Technical Reports Server (NTRS)

    Crist, E. P.; Malila, W. A. (Principal Investigator)

    1981-01-01

    A labeling technique is described which seeks to associate a sampling entity with a particular crop or crop group based on similarity of growing season and temporal-spectral patterns of development. Human analyst provide contextual information, after which labeling decisions are made automatically. Results of a test of the technique on a large, multi-year data set are reported. Grain labeling accuracies are similar to those achieved by human analysis techniques, while non-grain accuracies are lower. Recommendations for improvments and implications of the test results are discussed.

  19. Development and Evaluation of a Performance Modeling Flight Test Approach Based on Quasi Steady-State Maneuvers

    NASA Technical Reports Server (NTRS)

    Yechout, T. R.; Braman, K. B.

    1984-01-01

    The development, implementation and flight test evaluation of a performance modeling technique which required a limited amount of quasisteady state flight test data to predict the overall one g performance characteristics of an aircraft. The concept definition phase of the program include development of: (1) the relationship for defining aerodynamic characteristics from quasi steady state maneuvers; (2) a simplified in flight thrust and airflow prediction technique; (3) a flight test maneuvering sequence which efficiently provided definition of baseline aerodynamic and engine characteristics including power effects on lift and drag; and (4) the algorithms necessary for cruise and flight trajectory predictions. Implementation of the concept include design of the overall flight test data flow, definition of instrumentation system and ground test requirements, development and verification of all applicable software and consolidation of the overall requirements in a flight test plan.

  20. 40 CFR 63.1426 - Process vent requirements for determining organic HAP concentration, control efficiency, and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... performance test for those control techniques in accordance with paragraph (b)(6) of this section. The design..., immediately preceding the use of the control technique. A design evaluation shall also address other vent... paragraph (f)(1)(i) of this section, the design evaluation shall document the control efficiency and address...

  1. Longitudinal Joint Construction Techniques for Asphalt Pavements

    DOT National Transportation Integrated Search

    1997-08-01

    Thirty hot mix asphalt (HMA) test sections were constructed in Michigan (1992), Wisconsin (1992), Colorado (1994), and Pennsylvania (1995) to evaluate the effectiveness of twelve different longitudinal joint construction techniques. The performance o...

  2. A1297 GPR vs. hydro video clip.

    DOT National Transportation Integrated Search

    2014-03-01

    This research has examined the use of nondestructive techniques for concrete bridge deck condition assessments. The primary nondestructive testing/evaluation (NDT/NDE) technique utilized in this research was ground-coupled ground penetrating radar (G...

  3. Heat pipe investigations

    NASA Technical Reports Server (NTRS)

    Marshburn, J. P.

    1973-01-01

    Techniques associated with thermal-vacuum and bench testing, along with flight testing of the OAO-C spacecraft heat pipes are outlined, to show that the processes used in heat transfer design and testing are adequate for good performance evaluations.

  4. Use of the Marshall Space Flight Center solar simulator in collector performance evaluation

    NASA Technical Reports Server (NTRS)

    Humphries, W. R.

    1978-01-01

    Actual measured values from simulator checkout tests are detailed. Problems encountered during initial startup are discussed and solutions described. Techniques utilized to evaluate collector performance from simulator test data are given. Performance data generated in the simulator are compared to equivalent data generated during natural outdoor testing. Finally, a summary of collector performance parameters generated to date as a result of simulator testing are given.

  5. Evaluation of molecular markers for Phytophthora ramorum detection and identification: Testing for specificity using a standardized library of isolates

    Treesearch

    F.N. Martin; M.D. Coffey; K. Zeller; R.C. Hamelin; P. Tooley; M. Garbelotto; K.J.D. Hughes; T. Kubisiak; G.J. Bilodeau; L. Levy; C. Blomquist; P.H. Berger

    2009-01-01

    Given the importance of Phytophthora ramorum from a regulatory standpoint, it is imperative that molecular markers for pathogen detection are fully tested to evaluate their specificity in detection of the pathogen. In an effort to evaluate 11 reported diagnostic techniques, we assembled a standardized DNA library using accessions from the World...

  6. A quantitative investigation of the fracture pump-in/flowback test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plahn, S.V.; Nolte, K.G.; Thompson, L.G.

    1997-02-01

    Fracture-closure pressure is an important parameter for fracture treatment design and evaluation. The pump-in/flowback (PIFB) test is frequently used to estimate its magnitude. The test is attractive because bottomhole pressures (BHP`s) during flowback develop a distinct and repeatable signature. This is in contrast to the pump-in/shut-in test, where strong indications of fracture closure are rarely seen. Various techniques are used to extract closure pressure from the flowback-pressure response. Unfortunately, these techniques give different estimates for closure pressure, and their theoretical bases are not well established. The authors present results that place the PIFB test on a firmer foundation. A numericalmore » model is used to simulate the PIFB test and glean physical mechanisms contributing to the response. On the basis of their simulation results, they propose interpretation techniques that give better estimates of closure pressure than existing techniques.« less

  7. Methods and benefits of experimental seismic evaluation of nuclear power plants. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-07-01

    This study reviews experimental techniques, instrumentation requirements, safety considerations, and benefits of performing vibration tests on nuclear power plant containments and internal components. The emphasis is on testing to improve seismic structural models. Techniques for identification of resonant frequencies, damping, and mode shapes, are discussed. The benefits of testing with regard to increased damping and more accurate computer models are oulined. A test plan, schedule and budget are presented for a typical PWR nuclear power plant.

  8. Evaluation of Three Different Processing Techniques in the Fabrication of Complete Dentures

    PubMed Central

    Chintalacheruvu, Vamsi Krishna; Balraj, Rajasekaran Uttukuli; Putchala, Lavanya Sireesha; Pachalla, Sreelekha

    2017-01-01

    Aims and Objectives: The objective of the present study is to compare the effectiveness of three different processing techniques and to find out the accuracy of processing techniques through number of occlusal interferences and increase in vertical dimension after denture processing. Materials and Methods: A cross-sectional study was conducted on a sample of 18 patients indicated for complete denture fabrication was selected for the study and they were divided into three subgroups. Three processing techniques, compression molding and injection molding using prepolymerized resin and unpolymerized resin, were used to fabricate dentures for each of the groups. After processing, laboratory-remounted dentures were evaluated for number of occlusal interferences in centric and eccentric relations and change in vertical dimension through vertical pin rise in articulator. Data were analyzed using statistical test ANOVA and SPSS software version 19.0 by IBM was used. Results: Data obtained from three groups were subjected to one-way ANOVA test. After ANOVA test, results with significant variations were subjected to post hoc test. Number of occlusal interferences with compression molding technique was reported to be more in both centric and eccentric positions as compared to the two injection molding techniques with statistical significance in centric, protrusive, right lateral nonworking, and left lateral working positions (P < 0.05). Mean vertical pin rise (0.52 mm) was reported to more in compression molding technique as compared to injection molding techniques, which is statistically significant (P < 0.001). Conclusions: Within the limitations of this study, injection molding techniques exhibited less processing errors as compared to compression molding technique with statistical significance. There was no statistically significant difference in processing errors reported within two injection molding systems. PMID:28713763

  9. Evaluation of Three Different Processing Techniques in the Fabrication of Complete Dentures.

    PubMed

    Chintalacheruvu, Vamsi Krishna; Balraj, Rajasekaran Uttukuli; Putchala, Lavanya Sireesha; Pachalla, Sreelekha

    2017-06-01

    The objective of the present study is to compare the effectiveness of three different processing techniques and to find out the accuracy of processing techniques through number of occlusal interferences and increase in vertical dimension after denture processing. A cross-sectional study was conducted on a sample of 18 patients indicated for complete denture fabrication was selected for the study and they were divided into three subgroups. Three processing techniques, compression molding and injection molding using prepolymerized resin and unpolymerized resin, were used to fabricate dentures for each of the groups. After processing, laboratory-remounted dentures were evaluated for number of occlusal interferences in centric and eccentric relations and change in vertical dimension through vertical pin rise in articulator. Data were analyzed using statistical test ANOVA and SPSS software version 19.0 by IBM was used. Data obtained from three groups were subjected to one-way ANOVA test. After ANOVA test, results with significant variations were subjected to post hoc test. Number of occlusal interferences with compression molding technique was reported to be more in both centric and eccentric positions as compared to the two injection molding techniques with statistical significance in centric, protrusive, right lateral nonworking, and left lateral working positions ( P < 0.05). Mean vertical pin rise (0.52 mm) was reported to more in compression molding technique as compared to injection molding techniques, which is statistically significant ( P < 0.001). Within the limitations of this study, injection molding techniques exhibited less processing errors as compared to compression molding technique with statistical significance. There was no statistically significant difference in processing errors reported within two injection molding systems.

  10. Laboratory evaluation of anti-biofilm agents for use in dental unit waterlines.

    PubMed

    Meiller, T F; Kelley, J I; Baqui, A A; DePaola, L G

    2001-01-01

    Dental unit waterline biofilm has been recognized as a potential point of contamination and a risk to patients with any level of immunocompromise. Biofilm in dental unit waterlines, once established, has proven formidable to efforts in disinfection/disruption. This project compared standardized evaluation techniques by assessing the efficacy of a variety of agents that have been reported or suggested as useful in surface disinfection and/or antiseptic protocols. The zones of inhibition, minimum inhibitory/bactericidal concentrations and use-dilution with stainless steel carrier replicates tests assessed the disinfection of planktonic organisms using standardized microbial testing procedures. The disruption and/or disinfection of planktonic and biofilm organisms within naturally occurring dental unit waterlines were evaluated by culture and scanning electron microscopy. The six commercially available antimicrobial agents used to assess the techniques were bleach (sodium hypochlorite), Cavicide, glutaraldehyde, Listerine Antiseptic, Peridex and Sterilex Ultra. Comparisons between the results for each technique evaluated were determined for each product. All six agents demonstrated antimicrobial efficacy at the working concentrations designated by the manufacturers. Biofilm matrix elimination evaluated by scanning electron microscopy found virtually 0% elimination by glutaraldehyde to an estimated 90% elimination by Sterilex Ultra and bleach after one treatment. Treatment with Cavicide, Listerine Antiseptic and Peridex resulted in negligible elimination of the biofilm matrix. For comparability, the use of standardized testing techniques to evaluate a disinfection agent's efficacy against dental unit waterline contamination is essential. This project demonstrates a model system for evaluating disinfection agents potentially useful in the management of dental unit waterline biofilm, and should assist in educating the dental clinician in the appraisal of existing and future product claims.

  11. Software component quality evaluation

    NASA Technical Reports Server (NTRS)

    Clough, A. J.

    1991-01-01

    The paper describes a software inspection process that can be used to evaluate the quality of software components. Quality criteria, process application, independent testing of the process and proposed associated tool support are covered. Early results indicate that this technique is well suited for assessing software component quality in a standardized fashion. With automated machine assistance to facilitate both the evaluation and selection of software components, such a technique should promote effective reuse of software components.

  12. Evaluation of Programmed Instruction Techniques in Medical Interviewing. Final Report, June 15, 1966 to June 15, 1968.

    ERIC Educational Resources Information Center

    Adler, Leta McKinney; And Others

    Since the medical interview is usually considered to be the basis of all diagnosis and treatment in medicine, this study investigated alternative ways of improving medical interview techniques. To test the hypothesis that the visual (videotape) technique would be more effective than the lecturing or audiotape technique, 12 videotaped interviews…

  13. Testing and failure analysis to improve screening techniques for hermetically sealed metallized film capacitors for low energy applications

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Effective screening techniques are evaluated for detecting insulation resistance degradation and failure in hermetically sealed metallized film capacitors used in applications where low capacitor voltage and energy levels are common to the circuitry. A special test and monitoring system capable of rapidly scanning all test capacitors and recording faults and/or failures is examined. Tests include temperature cycling and storage as well as low, medium, and high voltage life tests. Polysulfone film capacitors are more heat stable and reliable than polycarbonate film units.

  14. Combined evaluation of commonly used techniques, including PCR, for diagnosis of mouse fur mites.

    PubMed

    Karlsson, Eleanor M; Pearson, Laura M; Kuzma, Kristen M; Burkholder, Tanya H

    2014-01-01

    Our study evaluated and compared the false-negative rates (FNR) of a wide array of fur-mite diagnostic tests, including 2 postmortem tests (pelt exam and sticky paper) and 3 antemortem tests (adhesive tape, fur pluck, and PCR). Past publications examining fur-mite diagnostic techniques primarily used paired comparisons, evaluating tests by their level of agreement with only one other test. However, different combinations or pairs of diagnostics are used in the different studies, making the results of these comparisons difficult to interpret across all available diagnostics. In the current study, mice from a conventionally maintained colony endemic for Myobia musculi were identified as positive based on at least one positive diagnostic test. From this pool of positive animals, the FNR of all tests were quantified. The PCR assay and the pelt exam performed the best, with 0% and 2% FNR respectively, whereas tape, fur-pluck, and sticky-paper tests showed 24%, 26%, and 36% FNR, respectively. Our study shows that for mice in a colony naturally infested with Myobia musculi, PCR testing can be used for reliable antemortem detection, and pelt exam performed by experienced examiners is reliable for postmortem detection.

  15. Emulation applied to reliability analysis of reconfigurable, highly reliable, fault-tolerant computing systems

    NASA Technical Reports Server (NTRS)

    Migneault, G. E.

    1979-01-01

    Emulation techniques applied to the analysis of the reliability of highly reliable computer systems for future commercial aircraft are described. The lack of credible precision in reliability estimates obtained by analytical modeling techniques is first established. The difficulty is shown to be an unavoidable consequence of: (1) a high reliability requirement so demanding as to make system evaluation by use testing infeasible; (2) a complex system design technique, fault tolerance; (3) system reliability dominated by errors due to flaws in the system definition; and (4) elaborate analytical modeling techniques whose precision outputs are quite sensitive to errors of approximation in their input data. Next, the technique of emulation is described, indicating how its input is a simple description of the logical structure of a system and its output is the consequent behavior. Use of emulation techniques is discussed for pseudo-testing systems to evaluate bounds on the parameter values needed for the analytical techniques. Finally an illustrative example is presented to demonstrate from actual use the promise of the proposed application of emulation.

  16. Blasting Rocks and Blasting Cars Applied Engineering

    ScienceCinema

    LBNL

    2017-12-09

    June 30, 2004 Berkeley Lab lecture: Deb Hopkins works with industries like automobile, mining and paper to improve their evaluation and measuring techniques. For several years, she has coordinated ... June 30, 2004 Berkeley Lab lecture: Deb Hopkins works with industries like automobile, mining and paper to improve their evaluation and measuring techniques. For several years, she has coordinated a program at Berkeley Lab funded under the Partnership for a New Generation of Vehicles, a collaboration between the federal government and the U.S. Council for Automotive Research. Nondestructive evaluation techniques to test a car's structural integrity are being developed for auto assembly lines.

  17. Wipe-rinse technique for quantitating microbial contamination on large surfaces.

    PubMed Central

    Kirschner, L E; Puleo, J R

    1979-01-01

    The evaluation of an improved wipe-rinse technique for the bioassay of large areas was undertaken due to inherent inadequacies in the cotton swab-rinse technique to which assay of spacecraft is currently restricted. Four types of contamination control cloths were initially tested. A polyester-bonded cloth (PBC) was selected for further evaluation because of its superior efficiency and handling characteristics. Results from comparative tests with PBC and cotton swabs on simulated spacecraft surfaces indicated a significantly higher recovery efficiency for the PBC than for the cotton (90.4 versus 75.2%). Of the sampling areas sites studied, PBC was found to be most effective on surface areas not exceeding 0.74 m2 (8.0 feet 2). PMID:394682

  18. Wipe-rinse technique for quantitating microbial contamination on large surfaces

    NASA Technical Reports Server (NTRS)

    Kirschner, L. E.; Puleo, J. R.

    1979-01-01

    The evaluation of an improved wipe-rinse technique for the bioassay of large areas was undertaken due to inherent inadequacies in the cotton swab-rinse technique to which assay of spacecraft is currently restricted. Four types of contamination control cloths were initially tested. A polyester-bonded cloth (PBC) was selected for further evaluation because of its superior efficiency and handling characteristics. Results from comparative tests with PBC and cotton swabs on simulated spacecraft surfaces indicated a significantly higher recovery efficiency for the PBC than for the cotton (90.4 versus 75.2%). Of the sampling area sites studied, PBC was found to be most effective on surface areas not exceeding 0.74 sq m (8.0 sq ft).

  19. A gamma-ray testing technique for spacecraft. [considering cosmic radiation effects

    NASA Technical Reports Server (NTRS)

    Gribov, B. S.; Repin, N. N.; Sakovich, V. A.; Sakharov, V. M.

    1977-01-01

    The simulated cosmic radiation effect on a spacecraft structure is evaluated by gamma ray testing in relation to structural thickness. A drawing of the test set-up is provided and measurement errors are discussed.

  20. Neurophysiological testing in anorectal disorders

    PubMed Central

    Remes-Troche, Jose M; Rao, Satish SC

    2013-01-01

    Neurophysiological tests of anorectal function can provide useful information regarding the integrity of neuronal innervation, as well as neuromuscular function. This information can give insights regarding the pathophysiological mechanisms that lead to several disorders of anorectal function, particularly fecal incontinence, pelvic floor disorders and dyssynergic defecation. Currently, several tests are available for the neurophysiological evaluation of anorectal function. These tests are mostly performed on patients referred to tertiary care centers, either following negative evaluations or when there is lack of response to conventional therapy. Judicious use of these tests can reveal significant and new understanding of the underlying mechanism(s) that could pave the way for better management of these disorders. In addition, these techniques are complementary to other modalities of investigation, such as pelvic floor imaging. The most commonly performed neurophysiological tests, along with their indications and clinical utility are discussed. Several novel techniques are evolving that may reveal new information on brain–gut interactions. PMID:19072383

  1. UNIX-based operating systems robustness evaluation

    NASA Technical Reports Server (NTRS)

    Chang, Yu-Ming

    1996-01-01

    Robust operating systems are required for reliable computing. Techniques for robustness evaluation of operating systems not only enhance the understanding of the reliability of computer systems, but also provide valuable feed- back to system designers. This thesis presents results from robustness evaluation experiments on five UNIX-based operating systems, which include Digital Equipment's OSF/l, Hewlett Packard's HP-UX, Sun Microsystems' Solaris and SunOS, and Silicon Graphics' IRIX. Three sets of experiments were performed. The methodology for evaluation tested (1) the exception handling mechanism, (2) system resource management, and (3) system capacity under high workload stress. An exception generator was used to evaluate the exception handling mechanism of the operating systems. Results included exit status of the exception generator and the system state. Resource management techniques used by individual operating systems were tested using programs designed to usurp system resources such as physical memory and process slots. Finally, the workload stress testing evaluated the effect of the workload on system performance by running a synthetic workload and recording the response time of local and remote user requests. Moderate to severe performance degradations were observed on the systems under stress.

  2. Field test of an alternative longwall gate road design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cox, R.M.; Vandergrift, T.L.; McDonnell, J.P.

    1994-01-01

    The US Bureau of Mines (USBM) MULSIM/ML modeling technique has been used to analyze anticipated stress distributions for a proposed alternative longwall gate road design for a western Colorado coal mine. The model analyses indicated that the alternative gate road design would reduce stresses in the headgate entry. To test the validity of the alternative gate road design under actual mining conditions, a test section of the alternative system was incorporated into a subsequent set of gate roads developed at the mine. The alternative gate road test section was instrumented with borehole pressure cells, as part of an ongoing USBMmore » research project to monitor ground pressure changes as longwall mining progressed. During the excavation of the adjacent longwall panels, the behavior of the alternative gate road system was monitored continuously using the USBM computer-assisted Ground Control Management System. During these field tests, the alternative gate road system was first monitored and evaluated as a headgate, and later monitored and evaluated as a tailgate. The results of the field tests confirmed the validity of using the MULSIM/NL modeling technique to evaluate mine designs.« less

  3. Repeatability of riparian vegetation sampling methods: how useful are these techniques for broad-scale, long-term monitoring?

    Treesearch

    Marc C. Coles-Ritchie; Richard C. Henderson; Eric K. Archer; Caroline Kennedy; Jeffrey L. Kershner

    2004-01-01

    Tests were conducted to evaluate variability among observers for riparian vegetation data collection methods and data reduction techniques. The methods are used as part of a largescale monitoring program designed to detect changes in riparian resource conditions on Federal lands. Methods were evaluated using agreement matrices, the Bray-Curtis dissimilarity metric, the...

  4. Multiple-Choice Testing Using Immediate Feedback--Assessment Technique (IF AT®) Forms: Second-Chance Guessing vs. Second-Chance Learning?

    ERIC Educational Resources Information Center

    Merrel, Jeremy D.; Cirillo, Pier F.; Schwartz, Pauline M.; Webb, Jeffrey A.

    2015-01-01

    Multiple choice testing is a common but often ineffective method for evaluating learning. A newer approach, however, using Immediate Feedback Assessment Technique (IF AT®, Epstein Educational Enterprise, Inc.) forms, offers several advantages. In particular, a student learns immediately if his or her answer is correct and, in the case of an…

  5. Techniques and Methods for Testing the Postural Function in Healthy and Pathological Subjects

    PubMed Central

    Paillard, Thierry; Noé, Frédéric

    2015-01-01

    The different techniques and methods employed as well as the different quantitative and qualitative variables measured in order to objectify postural control are often chosen without taking into account the population studied, the objective of the postural test, and the environmental conditions. For these reasons, the aim of this review was to present and justify the different testing techniques and methods with their different quantitative and qualitative variables to make it possible to precisely evaluate each sensory, central, and motor component of the postural function according to the experiment protocol under consideration. The main practical and technological methods and techniques used in evaluating postural control were explained and justified according to the experimental protocol defined. The main postural conditions (postural stance, visual condition, balance condition, and test duration) were also analyzed. Moreover, the mechanistic exploration of the postural function often requires implementing disturbing postural conditions by using motor disturbance (mechanical disturbance), sensory stimulation (sensory manipulation), and/or cognitive disturbance (cognitive task associated with maintaining postural balance) protocols. Each type of disturbance was tackled in order to facilitate understanding of subtle postural control mechanisms and the means to explore them. PMID:26640800

  6. Techniques and Methods for Testing the Postural Function in Healthy and Pathological Subjects.

    PubMed

    Paillard, Thierry; Noé, Frédéric

    2015-01-01

    The different techniques and methods employed as well as the different quantitative and qualitative variables measured in order to objectify postural control are often chosen without taking into account the population studied, the objective of the postural test, and the environmental conditions. For these reasons, the aim of this review was to present and justify the different testing techniques and methods with their different quantitative and qualitative variables to make it possible to precisely evaluate each sensory, central, and motor component of the postural function according to the experiment protocol under consideration. The main practical and technological methods and techniques used in evaluating postural control were explained and justified according to the experimental protocol defined. The main postural conditions (postural stance, visual condition, balance condition, and test duration) were also analyzed. Moreover, the mechanistic exploration of the postural function often requires implementing disturbing postural conditions by using motor disturbance (mechanical disturbance), sensory stimulation (sensory manipulation), and/or cognitive disturbance (cognitive task associated with maintaining postural balance) protocols. Each type of disturbance was tackled in order to facilitate understanding of subtle postural control mechanisms and the means to explore them.

  7. Determination of a quantitative parameter to evaluate swimming technique based on the maximal tethered swimming test.

    PubMed

    Soncin, Rafael; Mezêncio, Bruno; Ferreira, Jacielle Carolina; Rodrigues, Sara Andrade; Huebner, Rudolf; Serrão, Julio Cerca; Szmuchrowski, Leszek

    2017-06-01

    The aim of this study was to propose a new force parameter, associated with swimmers' technique and performance. Twelve swimmers performed five repetitions of 25 m sprint crawl and a tethered swimming test with maximal effort. The parameters calculated were: the mean swimming velocity for crawl sprint, the mean propulsive force of the tethered swimming test as well as an oscillation parameter calculated from force fluctuation. The oscillation parameter evaluates the force variation around the mean force during the tethered test as a measure of swimming technique. Two parameters showed significant correlations with swimming velocity: the mean force during the tethered swimming (r = 0.85) and the product of the mean force square root and the oscillation (r = 0.86). However, the intercept coefficient was significantly different from zero only for the mean force, suggesting that although the correlation coefficient of the parameters was similar, part of the mean velocity magnitude that was not associated with the mean force was associated with the product of the mean force square root and the oscillation. Thus, force fluctuation during tethered swimming can be used as a quantitative index of swimmers' technique.

  8. Universal test fixture for monolithic mm-wave integrated circuits calibrated with an augmented TRD algorithm

    NASA Technical Reports Server (NTRS)

    Romanofsky, Robert R.; Shalkhauser, Kurt A.

    1989-01-01

    The design and evaluation of a novel fixturing technique for characterizing millimeter wave solid state devices is presented. The technique utilizes a cosine-tapered ridge guide fixture and a one-tier de-embedding procedure to produce accurate and repeatable device level data. Advanced features of this technique include nondestructive testing, full waveguide bandwidth operation, universality of application, and rapid, yet repeatable, chip-level characterization. In addition, only one set of calibration standards is required regardless of the device geometry.

  9. Basic antenna transmitting characteristics using an extrapolation range measurement technique at a millimeter-wave band at NMIJ/AIST.

    PubMed

    Yamamoto, Tetsuya

    2007-06-01

    A novel test fixture operating at a millimeter-wave band using an extrapolation range measurement technique was developed at the National Metrology Institute of Japan (NMIJ). Here I describe the measurement system using a Q-band test fixture. I measured the relative insertion loss as a function of antenna separation distance and observed the effects of multiple reflections between the antennas. I also evaluated the antenna gain at 33 GHz using the extrapolation technique.

  10. 3RIP Evaluation of the Performance of the Search System Using a Realtime Simulation Technique.

    ERIC Educational Resources Information Center

    Lofstrom, Mats

    This report describes a real-time simulation experiment to evaluate the performance of the search and editing system 3RIP, an interactive system written in the language BLISS on a DEC-10 computer. The test vehicle, preliminary test runs, and capacity test are detailed, and the following conclusions are reported: (1) 3RIP performs well up to the…

  11. Linear Array Ultrasonic Test Results from Alkali-Silica Reaction (ASR) Specimens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clayton, Dwight A; Khazanovich, Dr. Lev; Salles, Lucio

    2016-04-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the variousmore » nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations.This report presents results of the ultrasound evaluation of four concrete slabs with varying levels of ASR damage present. This included an investigation of the experimental results, as well as a supplemental simulation considering the effect of ASR damage by elasto-dynamic wave propagation using a finite integration technique method. It was found that the Hilbert Transform Indicator (HTI), developed for quantification of freeze/thaw damage in concrete structures, could also be successfully utilized for quantification of ASR damage. internal microstructure flaws, and reinforcement locations.« less

  12. Quality assessment of internet pharmaceutical products using traditional and non-traditional analytical techniques.

    PubMed

    Westenberger, Benjamin J; Ellison, Christopher D; Fussner, Andrew S; Jenney, Susan; Kolinski, Richard E; Lipe, Terra G; Lyon, Robbe C; Moore, Terry W; Revelle, Larry K; Smith, Anjanette P; Spencer, John A; Story, Kimberly D; Toler, Duckhee Y; Wokovich, Anna M; Buhse, Lucinda F

    2005-12-08

    This work investigated the use of non-traditional analytical methods to evaluate the quality of a variety of pharmaceutical products purchased via internet sites from foreign sources and compared the results with those obtained from conventional quality assurance methods. Traditional analytical techniques employing HPLC for potency, content uniformity, chromatographic purity and drug release profiles were used to evaluate the quality of five selected drug products (fluoxetine hydrochloride, levothyroxine sodium, metformin hydrochloride, phenytoin sodium, and warfarin sodium). Non-traditional techniques, such as near infrared spectroscopy (NIR), NIR imaging and thermogravimetric analysis (TGA), were employed to verify the results and investigate their potential as alternative testing methods. Two of 20 samples failed USP monographs for quality attributes. The additional analytical methods found 11 of 20 samples had different formulations when compared to the U.S. product. Seven of the 20 samples arrived in questionable containers, and 19 of 20 had incomplete labeling. Only 1 of the 20 samples had final packaging similar to the U.S. products. The non-traditional techniques complemented the traditional techniques used and highlighted additional quality issues for the products tested. For example, these methods detected suspect manufacturing issues (such as blending), which were not evident from traditional testing alone.

  13. A1297 hydro demolition video versus GPR results : west bound lane.

    DOT National Transportation Integrated Search

    2014-03-01

    This research has examined the use of nondestructive techniques for concrete bridge deck condition : assessments. The primary nondestructive testing/evaluation (NDT/NDE) technique utilized in this research : was ground-coupled ground penetrating rada...

  14. A1193 hydro demolition video versus GPR results : east bound lane.

    DOT National Transportation Integrated Search

    2014-03-01

    This research has examined the use of nondestructive techniques for concrete bridge deck condition : assessments. The primary nondestructive testing/evaluation (NDT/NDE) technique utilized in this research : was ground-coupled ground penetrating rada...

  15. A1297 hydro demolition video versus GPR results : east bound lane.

    DOT National Transportation Integrated Search

    2014-03-01

    This research has examined the use of nondestructive techniques for concrete bridge deck condition : assessments. The primary nondestructive testing/evaluation (NDT/NDE) technique utilized in this research : was ground-coupled ground penetrating rada...

  16. Evaluation of primary immunization coverage of infants under universal immunization programme in an urban area of bangalore city using cluster sampling and lot quality assurance sampling techniques.

    PubMed

    K, Punith; K, Lalitha; G, Suman; Bs, Pradeep; Kumar K, Jayanth

    2008-07-01

    Is LQAS technique better than cluster sampling technique in terms of resources to evaluate the immunization coverage in an urban area? To assess and compare the lot quality assurance sampling against cluster sampling in the evaluation of primary immunization coverage. Population-based cross-sectional study. Areas under Mathikere Urban Health Center. Children aged 12 months to 23 months. 220 in cluster sampling, 76 in lot quality assurance sampling. Percentages and Proportions, Chi square Test. (1) Using cluster sampling, the percentage of completely immunized, partially immunized and unimmunized children were 84.09%, 14.09% and 1.82%, respectively. With lot quality assurance sampling, it was 92.11%, 6.58% and 1.31%, respectively. (2) Immunization coverage levels as evaluated by cluster sampling technique were not statistically different from the coverage value as obtained by lot quality assurance sampling techniques. Considering the time and resources required, it was found that lot quality assurance sampling is a better technique in evaluating the primary immunization coverage in urban area.

  17. Methods for Evaluating Mammography Imaging Techniques

    DTIC Science & Technology

    2000-06-01

    independent of disease prevalence . When test outcomes are dichotomous, sensitivity and specificity measure test accuracy. Sensitivity is the...phers were not provided with the disease prevalence in the The model we use accounts for within mammographer test set. Mammographers provided one

  18. Transient excitation and data processing techniques employing the fast fourier transform for aeroelastic testing

    NASA Technical Reports Server (NTRS)

    Jennings, W. P.; Olsen, N. L.; Walter, M. J.

    1976-01-01

    The development of testing techniques useful in airplane ground resonance testing, wind tunnel aeroelastic model testing, and airplane flight flutter testing is presented. Included is the consideration of impulsive excitation, steady-state sinusoidal excitation, and random and pseudorandom excitation. Reasons for the selection of fast sine sweeps for transient excitation are given. The use of the fast fourier transform dynamic analyzer (HP-5451B) is presented, together with a curve fitting data process in the Laplace domain to experimentally evaluate values of generalized mass, model frequencies, dampings, and mode shapes. The effects of poor signal to noise ratios due to turbulence creating data variance are discussed. Data manipulation techniques used to overcome variance problems are also included. The experience is described that was gained by using these techniques since the early stages of the SST program. Data measured during 747 flight flutter tests, and SST, YC-14, and 727 empennage flutter model tests are included.

  19. Damage characterization in engineering materials using a combination of optical, acoustic, and thermal techniques

    NASA Astrophysics Data System (ADS)

    Tragazikis, I. K.; Exarchos, D. A.; Dalla, P. T.; Matikas, T. E.

    2016-04-01

    This paper deals with the use of complimentary nondestructive methods for the evaluation of damage in engineering materials. The application of digital image correlation (DIC) to engineering materials is a useful tool for accurate, noncontact strain measurement. DIC is a 2D, full-field optical analysis technique based on gray-value digital images to measure deformation, vibration and strain a vast variety of materials. In addition, this technique can be applied from very small to large testing areas and can be used for various tests such as tensile, torsion and bending under static or dynamic loading. In this study, DIC results are benchmarked with other nondestructive techniques such as acoustic emission for damage localization and fracture mode evaluation, and IR thermography for stress field visualization and assessment. The combined use of these three nondestructive methods enables the characterization and classification of damage in materials and structures.

  20. Adhesive and Cohesive Strength in FeB/Fe2B Systems

    NASA Astrophysics Data System (ADS)

    Meneses-Amador, A.; Blancas-Pérez, D.; Corpus-Mejía, R.; Rodríguez-Castro, G. A.; Martínez-Trinidad, J.; Jiménez-Tinoco, L. F.

    2018-05-01

    In this work, FeB/Fe2B systems were evaluated by the scratch test. The powder-pack boriding process was performed on the surface of AISI M2 steel. The mechanical parameters, such as yield stress and Young's modulus of the boride layer, were obtained by the instrumented indentation technique. Residual stresses produced on the boride layer were estimated by using the x-ray diffraction (XRD) technique. The scratch test was performed in order to evaluate the cohesive/adhesive strength of the FeB/Fe2B coating. In addition, a numerical evaluation of the scratch test on boride layers was performed by the finite element method. Maximum principal stresses were related to the failure mechanisms observed by the experimental scratch test. Shear stresses at the interfaces of the FeB/Fe2B/substrate system were also evaluated. Finally, the results obtained provide essential information about the effect of the layer thickness, the residual stresses, and the resilience modulus on the cohesive/adhesive strength in FeB/Fe2B systems.

  1. Live fire testing requirements - Assessing the impact

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Bryon, J.F.

    1992-08-01

    Full-up live-fire testing (LFT) of aircraft configured for combat is evaluated in terms of the practical implications of the technique. LFT legislation requires the testing of tactical fighters, helicopters, and other aircraft when they are loaded with the flammables and explosives associated with combat. LFT permits the study of damage mechanisms and battle-damage repair techniques during the design phase, and probability-of-kill estimates and novel systems designs can be developed based on LFT data.

  2. Data analysis techniques used at the Oak Ridge Y-12 plant flywheel evaluation laboratory

    NASA Astrophysics Data System (ADS)

    Steels, R. S., Jr.; Babelay, E. F., Jr.

    1980-07-01

    Some of the more advanced data analysis techniques applied to the problem of experimentally evaluating the performance of high performance composite flywheels are presented. Real time applications include polar plots of runout with interruptions relating to balance and relative motions between parts, radial growth measurements, and temperature of the spinning part. The technique used to measure torque applied to a containment housing during flywheel failure is also presented. The discussion of pre and post test analysis techniques includes resonant frequency determination with modal analysis, waterfall charts, and runout signals at failure.

  3. Biomechanical testing simulation of a cadaver spine specimen: development and evaluation study.

    PubMed

    Ahn, Hyung Soo; DiAngelo, Denis J

    2007-05-15

    This article describes a computer model of the cadaver cervical spine specimen and virtual biomechanical testing. To develop a graphics-oriented, multibody model of a cadaver cervical spine and to build a virtual laboratory simulator for the biomechanical testing using physics-based dynamic simulation techniques. Physics-based computer simulations apply the laws of physics to solid bodies with defined material properties. This technique can be used to create a virtual simulator for the biomechanical testing of a human cadaver spine. An accurate virtual model and simulation would complement tissue-based in vitro studies by providing a consistent test bed with minimal variability and by reducing cost. The geometry of cervical vertebrae was created from computed tomography images. Joints linking adjacent vertebrae were modeled as a triple-joint complex, comprised of intervertebral disc joints in the anterior region, 2 facet joints in the posterior region, and the surrounding ligament structure. A virtual laboratory simulation of an in vitro testing protocol was performed to evaluate the model responses during flexion, extension, and lateral bending. For kinematic evaluation, the rotation of motion segment unit, coupling behaviors, and 3-dimensional helical axes of motion were analyzed. The simulation results were in correlation with the findings of in vitro tests and published data. For kinetic evaluation, the forces of the intervertebral discs and facet joints of each segment were determined and visually animated. This methodology produced a realistic visualization of in vitro experiment, and allowed for the analyses of the kinematics and kinetics of the cadaver cervical spine. With graphical illustrations and animation features, this modeling technique has provided vivid and intuitive information.

  4. 30 CFR 282.23 - Testing Plan.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Testing Plan. 282.23 Section 282.23 Mineral... § 282.23 Testing Plan. All testing activities shall be conducted in accordance with a Testing Plan..., to carry out a pilot program to evaluate processing techniques or technology or mining equipment, or...

  5. 16 CFR 1209.5 - Test procedures for corrosiveness.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., combed, or otherwise mixed to reasonably assure homogeneity in the cellulose insulation test specimens... Evaluating Corrosion Test Specimens,” published by American Society for Testing and Materials, 1916 Race... acid (plus water). To avoid injury in this and subsequent techniques when mixing acid and water...

  6. Comparative Evaluation of Conventional and Accelerated Castings on Marginal Fit and Surface Roughness.

    PubMed

    Jadhav, Vivek Dattatray; Motwani, Bhagwan K; Shinde, Jitendra; Adhapure, Prasad

    2017-01-01

    The aim of this study was to evaluate the marginal fit and surface roughness of complete cast crowns made by a conventional and an accelerated casting technique. This study was divided into three parts. In Part I, the marginal fit of full metal crowns made by both casting techniques in the vertical direction was checked, in Part II, the fit of sectional metal crowns in the horizontal direction made by both casting techniques was checked, and in Part III, the surface roughness of disc-shaped metal plate specimens made by both casting techniques was checked. A conventional technique was compared with an accelerated technique. In Part I of the study, the marginal fit of the full metal crowns as well as in Part II, the horizontal fit of sectional metal crowns made by both casting techniques was determined, and in Part III, the surface roughness of castings made with the same techniques was compared. The results of the t -test and independent sample test do not indicate statistically significant differences in the marginal discrepancy detected between the two casting techniques. For the marginal discrepancy and surface roughness, crowns fabricated with the accelerated technique were significantly different from those fabricated with the conventional technique. Accelerated casting technique showed quite satisfactory results, but the conventional technique was superior in terms of marginal fit and surface roughness.

  7. Reliability of breath by breath spirometry and relative flow-time indices for pulmonary function testing in horses.

    PubMed

    Burnheim, K; Hughes, K J; Evans, D L; Raidal, S L

    2016-11-28

    Respiratory problems are common in horses, and are often diagnosed as a cause of poor athletic performance. Reliable, accurate and sensitive spirometric tests of airway function in resting horses would assist with the diagnosis of limitations to breathing and facilitate investigations of the effects of various treatments on breathing capacity. The evaluation of respiratory function in horses is challenging and suitable procedures are not widely available to equine practitioners. The determination of relative flow or flow-time measures is used in paediatric patients where compliance may limit conventional pulmonary function techniques. The aim of the current study was to characterise absolute and relative indices of respiratory function in healthy horses during eupnoea (tidal breathing) and carbon dioxide (CO 2 )-induced hyperpnoea (rebreathing) using a modified mask pneumotrachographic technique well suited to equine practice, and to evaluate the reliability of this technique over three consecutive days. Coefficients of variation, intra-class correlations, mean differences and 95% confidence intervals across all days of testing were established for each parameter. The technique provided absolute measures of respiratory function (respiratory rate, tidal volume, peak inspiratory and expiratory flows, time to peak flow) consistent with previous studies and there was no significant effect of day on any measure of respiratory function. Variability of measurements was decreased during hyperpnea caused by rebreathing CO 2 , but a number of relative flow-time variables demonstrated good agreement during eupnoeic respiration. The technique was well tolerated by horses and study findings suggest the technique is suitable for evaluation of respiratory function in horses. The use of relative flow-time variables provided reproducible (consistent) results, suggesting the technique may be of use for repeated measures studies in horses during tidal breathing or rebreathing.

  8. Accuracy of Different Implant Impression Techniques: Evaluation of New Tray Design Concept.

    PubMed

    Liu, David Yu; Cader, Fathima Nashmie; Abduo, Jaafar; Palamara, Joseph

    2017-12-29

    To evaluate implant impression accuracy with a new tray design concept in comparison to nonsplinted and splinted impression techniques for a 2-implant situation. A reference bar titanium framework was fabricated to fit on 2 parallel implants. The framework was used to generate a resin master model with 2 implants that fit precisely against the framework. Three impression techniques were evaluated: (1) nonsplinted, (2) splinted, and (3) nonsplinted with modified tray impressions. All the trays were fabricated from light-cured acrylic resin material with openings that corresponded to the implant impression copings. Ten impressions were taken for each technique using poly(vinyl siloxane) impression material. The impressions were poured with type IV dental stone to generate the test casts. A rosette strain gauge was bonded to the middle of the framework. As the framework retaining screws were tightened on each test cast, the developed strains were recorded until the completion of the tightening to 35 Ncm. The generated strains of the rosette strain gauge were used to calculate the maximum principal strain. A statistically significant difference was observed among the different impression techniques. The modified tray design impression technique was associated with the least framework strains, which indicates greater accuracy compared with the other techniques. There was no significant difference between the splinted and the nonsplinted impression techniques. The new tray design concept appeared to produce more accurate implant impressions than the other techniques. Despite the statistical difference among the impression techniques, the clinical significance of this difference is yet to be determined. © 2017 by the American College of Prosthodontists.

  9. Assessing the Effectiveness of Statistical Classification Techniques in Predicting Future Employment of Participants in the Temporary Assistance for Needy Families Program

    ERIC Educational Resources Information Center

    Montoya, Isaac D.

    2008-01-01

    Three classification techniques (Chi-square Automatic Interaction Detection [CHAID], Classification and Regression Tree [CART], and discriminant analysis) were tested to determine their accuracy in predicting Temporary Assistance for Needy Families program recipients' future employment. Technique evaluation was based on proportion of correctly…

  10. Evaluation and comparison of clinical results of femoral fixation devices in arthroscopic anterior cruciate ligament reconstruction.

    PubMed

    Aydin, Deniz; Ozcan, Mert

    2016-03-01

    Several femoral fixation devices are available for hamstring tendon autograft in anterior cruciate ligament (ACL) reconstruction, but the best technique is debatable. We hypothesised that different suspensory femoral fixation techniques have no superiority over each other. The aim of this study was to evaluate and compare the clinical results of different suspensory femoral fixation devices in arthroscopic ACL reconstruction. This was a Level III, retrospective, comparative study. A total of 100 consecutive patients who underwent arthroscopic ACL reconstruction in a single institution with a mean follow-up time of 40 months (12-67 months) were divided into three groups according to femoral fixation devices as 'Endobutton' (n=34), 'Transfix' (n=35) and 'Aperfix' (n=31). The length of painful period after surgery, time to return to work and sporting activities, final range of motion, anterior drawer and Lachman tests, knee instability symptoms, International Knee Documentation Committee (IKDC) subjective knee evaluation score, Short Form 36 (SF-36) score, Lysholm knee score and Tegner point of the patients were evaluated and compared between groups. There were no significant differences between the groups. All techniques led to significant recovery in knee instability tests and symptoms. In this study, the clinical results of different suspensory femoral fixation techniques were found to be similar. We believe that different femoral fixation techniques have no effect on clinical results provided that the technique is correctly applied. The surgeon must choose a technique appropriate to his or her experience. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Food and Food-Odor Preferences in Dogs: A Pilot Study

    PubMed Central

    Péron, Franck; Cambou, Stéphanie; Callejon, Laurence; Wynne, Clive D.L.

    2017-01-01

    Abstract Evaluation of food palatability and preference is of great importance to the pet food industry. One common technique for evaluating palatability is a 2-bowl test in which 2 products are offered simultaneously and food consumption is measured. This yields clear results with dogs trained to routinely conduct such comparisons, but it is less clear how this extends to untrained pet dogs. In addition, prior research indicates that olfaction is important in food preference, but methods for evaluating odor preference in canines are currently lacking. In this study, we developed a modified 2-bowl test for evaluation of food preferences in pet dogs with minimal training, and an olfactometer technique for the evaluation of odor preferences. In our 2-bowl procedure, we observed clear preferences among 4 commercial food products in 6 pet dogs. Across repeated testing, preferences strengthened, but the first evaluation accurately estimated the direction and significance of preference. In addition, dogs typically (89% of the time) consumed more of the food they chose first, suggesting they did not need to taste each food to choose. Our odor preference olfactometer assessment, however, did not reveal odor preferences other than that dogs preferred to sniff a food odor over clean air. Further work will be needed to identify methods of measuring odor preferences amongst food odors for dogs, but the modified 2-bowl test shows promise for further testing in pet dogs.

  12. Comparison of measured and calculated dynamic loads for the Mod-2 2.5 mW wind turbine system

    NASA Technical Reports Server (NTRS)

    Zimmerman, D. K.; Shipley, S. A.; Miller, R. D.

    1995-01-01

    The Boeing Company, under contract to the Electric Power Research Institute (EPRI), has completed a test program on the Mod-2 wind turbines at Goodnoe Hills, Washington. The objectives were to update fatigue load spectra, discern site and machine differences, measure vortex generator effects, and to evaluate rotational sampling techniques. This paper shows the test setup and loads instrumentation, loads data comparisons and test/analysis correlations. Test data are correlated with DYLOSAT predictions using both the NASA interim turbulence model and rotationally sampled winds as inputs. The latter is demonstrated to have the potential to improve the test/analysis correlations. The paper concludes with an assessment of the importance of vortex generators, site dependence, and machine differences on fatigue loads. The adequacy of prediction techniques used are evaluated and recommendations are made for improvements to the methodology.

  13. Real-Time Global Nonlinear Aerodynamic Modeling for Learn-To-Fly

    NASA Technical Reports Server (NTRS)

    Morelli, Eugene A.

    2016-01-01

    Flight testing and modeling techniques were developed to accurately identify global nonlinear aerodynamic models for aircraft in real time. The techniques were developed and demonstrated during flight testing of a remotely-piloted subscale propeller-driven fixed-wing aircraft using flight test maneuvers designed to simulate a Learn-To-Fly scenario. Prediction testing was used to evaluate the quality of the global models identified in real time. The real-time global nonlinear aerodynamic modeling algorithm will be integrated and further tested with learning adaptive control and guidance for NASA Learn-To-Fly concept flight demonstrations.

  14. Blasting Rocks and Blasting Cars Applied Engineering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LBNL

    2008-07-02

    June 30, 2004 Berkeley Lab lecture: Deb Hopkins works with industries like automobile, mining and paper to improve their evaluation and measuring techniques. For several years, she has coordinated ... June 30, 2004 Berkeley Lab lecture: Deb Hopkins works with industries like automobile, mining and paper to improve their evaluation and measuring techniques. For several years, she has coordinated a program at Berkeley Lab funded under the Partnership for a New Generation of Vehicles, a collaboration between the federal government and the U.S. Council for Automotive Research. Nondestructive evaluation techniques to test a car's structural integrity are being developed formore » auto assembly lines.« less

  15. Development and evaluation of vision rehabilitation devices.

    PubMed

    Luo, Gang; Peli, Eli

    2011-01-01

    We have developed a range of vision rehabilitation devices and techniques for people with impaired vision due to either central vision loss or severely restricted peripheral visual field. We have conducted evaluation studies with patients to test the utilities of these techniques in an effort to document their advantages as well as their limitations. Here we describe our work on a visual field expander based on a head mounted display (HMD) for tunnel vision, a vision enhancement device for central vision loss, and a frequency domain JPEG/MPEG based image enhancement technique. All the evaluation studies included visual search paradigms that are suitable for conducting indoor controllable experiments.

  16. ELISA test for anti-neutrophil cytoplasm antibodies detection evaluated by a computer screen photo-assisted technique.

    PubMed

    Filippini, D; Tejle, K; Lundström, I

    2005-08-15

    The computer screen photo-assisted technique (CSPT), a method for substance classification based on spectral fingerprinting, which involves just a computer screen and a web camera as measuring platform is used here for the evaluation of a prospective enzyme-linked immunosorbent assay (ELISA). A anti-neutrophil cytoplasm antibodies (ANCA-ELISA) test, typically used for diagnosing patients suffering from chronic inflammatory disorders in the skin, joints, blood vessels and other tissues is comparatively tested with a standard microplate reader and CSPT, yielding equivalent results at a fraction of the instrumental costs. The CSPT approach is discussed as a distributed measuring platform allowing decentralized measurements in routine applications, whereas keeping centralized information management due to its natural network embedded operation.

  17. An In vitro Comparison and Evaluation of Sealing Ability of Newly Introduced C-point System, Cold Lateral Condensation, and Thermoplasticized Gutta-Percha Obturating Technique: A Dye Extraction Study.

    PubMed

    Sinhal, Tapati Manohar; Shah, Ruchi Rani Purvesh; Jais, Pratik Subhas; Shah, Nimisha Chinmay; Hadwani, Krupali Dhirubhai; Rothe, Tushar; Sinhal, Neha Nilesh

    2018-01-01

    The aim of this study is to compare and to evaluate sealing ability of newly introduced C-point system, cold lateral condensation, and thermoplasticized gutta-percha obturating technique using a dye extraction method. Sixty extracted maxillary central incisors were decoronated below the cementoenamel junction. Working length was established, and biomechanical preparation was done using K3 rotary files with standard irrigation protocol. Teeth were divided into three groups according to the obturation protocol; Group I-Cold lateral condensation, Group II-Thermoplasticized gutta-percha, and Group III-C-Point obturating system. After obturation all samples were subjected to microleakage assessment using dye extraction method. Obtained scores will be statistical analyzed using ANOVA test and post hoc Tukey's test. One-way analysis of variance revealed that there is significant difference among the three groups with P value (0.000 < 0.05). Tukey's HSD post hoc tests for multiple comparisons test shows that the Group II and III perform significantly better than Group I. Group III performs better than Group II with no significant difference. All the obturating technique showed some degree of microleakage. Root canals filled with C-point system showed least microleakage followed by thermoplasticized obturating technique with no significant difference among them. C-point obturation system could be an alternative to the cold lateral condensation technique.

  18. Evaluation of a new serological technique for detecting rabies virus antibodies following vaccination.

    PubMed

    Ma, Xiaoyue; Niezgoda, Michael; Blanton, Jesse D; Recuenco, Sergio; Rupprecht, Charles E

    2012-08-03

    Two major techniques are currently used to estimate rabies virus antibody values: neutralization assays, such as the rapid fluorescent focus inhibition test (RFFIT), and enzyme-linked immunosorbent assays (ELISAs). The RFFIT is considered the gold standard assay and has been used to assess the titer of rabies virus neutralizing antibodies for more than three decades. In the late 1970s, ELISA began to be used to estimate the level of rabies virus antibody and has recently been used by some laboratories as an alternate screening test for animal sera. Although the ELISA appears simpler, safer and more efficient, the assay is less sensitive in detecting low values of rabies virus neutralizing antibodies than neutralization tests. This study was designed to evaluate a new ELISA-based method for detecting rabies virus binding antibody. This new technique uses electro-chemi-luminescence labels and carbon electrode plates to detect binding events. In this comparative study, the RFFIT and the new ELISA-based technique were used to evaluate the level of rabies virus antibodies in human and animal serum samples. By using a conservative approximation of 0.15 IU/ml as a cutoff point, the new ELISA-based technique demonstrated a sensitivity of 100% and a specificity of 95% for human samples and for experimental animal samples. The sensitivity and specificity for field animal samples was 96% and 95%, respectively. The preliminary results from this study appear promising and demonstrate a higher sensitivity than traditional ELISA methods. Published by Elsevier Ltd.

  19. Comparison of two surgical procedures for use of the acellular dermal matrix graft in the treatment of gingival recessions: a randomized controlled clinical study.

    PubMed

    Felipe, Maria Emília M C; Andrade, Patrícia F; Grisi, Marcio F M; Souza, Sérgio L S; Taba, Mário; Palioto, Daniela B; Novaes, Arthur B

    2007-07-01

    The aim of this randomized, controlled, clinical investigation was to compare two surgical techniques for root coverage with the acellular dermal matrix graft to evaluate which technique provided better root coverage, a better esthetic result, and less postoperative discomfort. Fifteen patients with bilateral Miller Class I or II gingival recessions were selected. Fifteen pairs of recessions were treated and assigned randomly to the test group, and the contralateral recessions were assigned to the control group. The control group was treated with a broader flap and vertical releasing incisions; the test group was treated with the proposed surgical technique, without vertical releasing incisions. The clinical parameters evaluated were probing depth, relative clinical attachment level, gingival recession (GR), width of keratinized tissue, thickness of keratinized tissue, esthetic result, and pain evaluation. The measurements were taken before the surgeries and after 6 months. At baseline, all parameters were similar for both groups. At 6 months, a statistically significant greater reduction in GR favored the control group. The percentage of root coverage was 68.98% and 84.81% for the test and control groups, respectively. The esthetic result was equivalent between the groups, and all patients tolerated both procedures well. Both techniques provided significant root coverage, good esthetic results, and similar levels of postoperative discomfort. However, the control technique had statistically significantly better results for root coverage of localized gingival recessions.

  20. Maximum acceptable weight of lift reflects peak lumbosacral extension moments in a functional capacity evaluation test using free style, stoop and squat lifting.

    PubMed

    Kuijer, P P F M; van Oostrom, S H; Duijzer, K; van Dieën, J H

    2012-01-01

    It is unclear whether the maximum acceptable weight of lift (MAWL), a common psychophysical method, reflects joint kinetics when different lifting techniques are employed. In a within-participants study (n = 12), participants performed three lifting techniques--free style, stoop and squat lifting from knee to waist level--using the same dynamic functional capacity evaluation lifting test to assess MAWL and to calculate low back and knee kinetics. We assessed which knee and back kinetic parameters increased with the load mass lifted, and whether the magnitudes of the kinetic parameters were consistent across techniques when lifting MAWL. MAWL was significantly different between techniques (p = 0.03). The peak lumbosacral extension moment met both criteria: it had the highest association with the load masses lifted (r > 0.9) and was most consistent between the three techniques when lifting MAWL (ICC = 0.87). In conclusion, MAWL reflects the lumbosacral extension moment across free style, stoop and squat lifting in healthy young males, but the relation between the load mass lifted and lumbosacral extension moment is different between techniques. Tests of maximum acceptable weight of lift (MAWL) from knee to waist height are used to assess work capacity of individuals with low-back disorders. This article shows that the MAWL reflects the lumbosacral extension moment across free style, stoop and squat lifting in healthy young males, but the relation between the load mass lifted and lumbosacral extension moment is different between techniques. This suggests that standardisation of lifting technique used in tests of the MAWL would be indicated if the aim is to assess the capacity of the low back.

  1. Electrophysiology of Cranial Nerve Testing: Spinal Accessory and Hypoglossal Nerves.

    PubMed

    Stino, Amro M; Smith, Benn E

    2018-01-01

    Multiple techniques have been developed for the electrodiagnostic evaluation of cranial nerves XI and XII. Each of these carries both benefits and limitations, with more techniques and data being available in the literature for spinal accessory than hypoglossal nerve evaluation. Spinal accessory and hypoglossal neuropathy are relatively uncommon cranial mononeuropathies that may be evaluated in the outpatient electrodiagnostic laboratory setting. A review of available literature using PubMed was conducted regarding electrodiagnostic technique in the evaluation of spinal accessory and hypoglossal nerves searching for both routine nerve conduction studies and repetitive nerve conduction studies. The review provided herein provides a resource by which clinical neurophysiologists may develop and implement clinical and research protocols for the evaluation of both of these lower cranial nerves in the outpatient setting.

  2. Development of a Pulsed Pressure-Based Technique for Cavitation Damage Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ren, Fei; Wang, Jy-An John; Liu, Yun

    2012-01-01

    Cavitation occurs in many fluid systems and can lead to severe material damage. To assist the study of cavitation damage, a novel testing method utilizing pulsed pressure was developed. In this talk, the scientific background and the technical approach of this development are present and preliminary testing results are discussed. It is expected that this technique can be used to evaluate cavitation damage under various testing conditions including harsh environments such as those relevant to geothermal power generation.

  3. Test Procedures for Characterizing, Evaluating, and Managing Separator Materials used in Secondary Alkaline Batteries

    NASA Technical Reports Server (NTRS)

    Guasp, Edwin; Manzo, Michelle A.

    1997-01-01

    Secondary alkaline batteries, such as nickel-cadmium and silver-zinc, are commonly used for aerospace applications. The uniform evaluation and comparison of separator properties for these systems is dependent upon the measurement techniques. This manual presents a series of standard test procedures that can be used to evaluate, compare, and select separator materials for use in alkaline batteries. Detailed test procedures evaluating the following characteristics are included in this manual: physical measurements of thickness and area weight, dimensional stability measurements, electrolyte retention, resistivity, permeability as measured via bubble pressure, surface evaluation via SEM, chemical stability, and tensile strength.

  4. Office of the Secretary of Defense Research, Development Test and Evaluation, Development and Test Evaluation, Defense, Director of Operational Test and Evaluation Defense, FY 1994 Budget Estimates, Justification of Estimates Submitted to Congress April 1993

    DTIC Science & Technology

    1993-04-01

    separation capability. o Demonstrate advanced KKVs in the 6-20 KG weight class. o Test planning for SRAM/LEAP and PATRIOT/LEAP integrated technology...packaging techniques to reduce satellite size, weight , power, and total system costs. Further development of these technologies are absolutely 4...1993 o Developed a master plan with a delivery schedule for each light- weight subassembly in the sensor integration payload. o Finalized a contract for

  5. Development of a Postacute Hospital Item Bank for the New Pediatric Evaluation of Disability Inventory-Computer Adaptive Test

    ERIC Educational Resources Information Center

    Dumas, Helene M.

    2010-01-01

    The PEDI-CAT is a new computer adaptive test (CAT) version of the Pediatric Evaluation of Disability Inventory (PEDI). Additional PEDI-CAT items specific to postacute pediatric hospital care were recently developed using expert reviews and cognitive interviewing techniques. Expert reviews established face and construct validity, providing positive…

  6. A Test of Two Citation Checking Techniques for Evaluating Political Science Collections in University Libraries.

    ERIC Educational Resources Information Center

    Nisonger, Thomas E.

    1983-01-01

    Using random selection of citations from journal articles, two specific permutations of the citation checking approach to university library collection evaluation are tested on political science collections in five university libraries in the Washington, D.C. area. The history of the citation checking approach is reviewed. Forty-three references…

  7. ITEM SELECTION TECHNIQUES AND EVALUATION OF INSTRUCTIONAL OBJECTIVES.

    ERIC Educational Resources Information Center

    COX, RICHARD C.

    THE VALIDITY OF AN EDUCATIONAL ACHIEVEMENT TEST DEPENDS UPON THE CORRESPONDENCE BETWEEN SPECIFIED EDUCATIONAL OBJECTIVES AND THE EXTENT TO WHICH THESE OBJECTIVES ARE MEASURED BY THE EVALUATION INSTRUMENT. THIS STUDY IS DESIGNED TO EVALUATE THE EFFECT OF STATISTICAL ITEM SELECTION ON THE STRUCTURE OF THE FINAL EVALUATION INSTRUMENT AS COMPARED WITH…

  8. Comprehensive Field Test and Evaluation of an Electronic Signpost AVM System. Volume I. Test Results

    DOT National Transportation Integrated Search

    1977-08-01

    The report covers the activities of Phase I which involved the installation and test of a HI3 AVM System in Philadelphia, Pennsylvania, during the winter of 1976-1977. A summary report on all systems tested is Experiments on four different techniques...

  9. Characterization of fluid flow by digital correlation of scattered light

    NASA Technical Reports Server (NTRS)

    Gilbert, John A.; Matthys, Donald R.

    1989-01-01

    The objective is to produce a physical system suitable for a space environment that can measure fluid velocities in a three-dimensional volume by the development of a particle correlation velocimetry technique. Experimental studies were conducted on a field test cell to demonstrate the suitability and accuracy of digital correlation techniques for measuring two-dimensional fluid flows. This objective was satisfied by: (1) the design of an appropriate illumination and detection system for making velocity measurements within a test cell; (2) the design and construction of a test cell; (3) the preliminary evaluations on fluid and seeding requirements; and (4) the performance of controlled tests using a multiple exposure correlation technique. This presentation is represented by viewgraphs with very little text.

  10. Response Time Analysis and Test of Protection System Instrument Channels for APR1400 and OPR1000

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Chang Jae; Han, Seung; Yun, Jae Hee

    2015-07-01

    Safety limits are required to maintain the integrity of physical barriers designed to prevent the uncontrolled release of radioactive materials in nuclear power plants. The safety analysis establishes two critical constraints that include an analytical limit in terms of a measured or calculated variable, and a specific time after the analytical limit is reached to begin protective action. Keeping with the nuclear regulations and industry standards, satisfying these two requirements will ensure that the safety limit will not be exceeded during the design basis event, either an anticipated operational occurrence or a postulated accident. Various studies on the setpoint determinationmore » methodology for the safety-related instrumentation have been actively performed to ensure that the requirement of the analytical limit is satisfied. In particular, the protection setpoint methodology for the advanced power reactor 1400 (APP1400) and the optimized power reactor 1000 (OPR1000) has been recently developed to cover both the design basis event and the beyond design basis event. The developed setpoint methodology has also been quantitatively validated using specific computer programs and setpoint calculations. However, the safety of nuclear power plants cannot be fully guaranteed by satisfying the requirement of the analytical limit. In spite of the response time verification requirements of nuclear regulations and industry standards, it is hard to find the studies on the systematically integrated methodology regarding the response time evaluation. In cases of APR1400 and OPR1000, the response time analysis for the plant protection system is partially included in the setpoint calculation and the response time test is separately performed via the specific plant procedure. The test technique has a drawback which is the difficulty to demonstrate completeness of timing test. The analysis technique has also a demerit of resulting in extreme times that not actually possible. Thus, the establishment of the systematic response time evaluation methodology is needed to justify the conformance to the response time requirement used in the safety analysis. This paper proposes the response time evaluation methodology for APR1400 and OPR1000 using the combined analysis and test technique to confirm that the plant protection system can meet the analytical response time assumed in the safety analysis. In addition, the results of the quantitative evaluation performed for APR1400 and OPR1000 are presented in this paper. The proposed response time analysis technique consists of defining the response time requirement, determining the critical signal path for the trip parameter, allocating individual response time to each component on the signal path, and analyzing the total response time for the trip parameter, and demonstrates that the total analyzed response time does not exceed the response time requirement. The proposed response time test technique is composed of defining the response time requirement, determining the critical signal path for the trip parameter, determining the test method for each component on the signal path, performing the response time test, and demonstrates that the total test result does not exceed the response time requirement. The total response time should be tested in a single test that covers from the sensor to the final actuation device on the instrument channel. When the total channel is not tested in a single test, separate tests on groups of components or single components including the total instrument channel shall be combined to verify the total channel response. For APR1400 and OPR1000, the ramp test technique is used for the pressure and differential pressure transmitters and the step function testing technique is applied to the signal processing equipment and final actuation device. As a result, it can be demonstrated that the response time requirement is satisfied by the combined analysis and test technique. Therefore, the proposed methodology in this paper plays a crucial role in guaranteeing the safety of the nuclear power plants systematically satisfying one of two critical requirements from the safety analysis. (authors)« less

  11. Comparison of Clinical Results, Second-Look Arthroscopic Findings, and MRI Findings Between the Transportal and Outside-In Techniques for Double-Bundle Anatomic Anterior Cruciate Ligament Reconstruction: A Prospective, Randomized Controlled Trial With a Minimum 2-Year Follow-up.

    PubMed

    Kim, Jae Gyoon; Kang, Seung Hoon; Kim, Jun Ho; Lim, Chae Ouk; Wang, Joon Ho

    2018-03-01

    Although image analysis has shown that the outside-in (OI) technique is associated with different femoral tunnel geometry than the transportal (TP) technique in anatomic anterior cruciate ligament (ACL) reconstruction, it is not known whether clinical results differ between the 2 techniques. To compare clinical results, second-look arthroscopic findings, and magnetic resonance imaging (MRI) findings between the TP and OI techniques in anatomic double-bundle (DB) ACL reconstruction. Randomized controlled trial; Level of evidence, 2. From November 2010 to March 2013, 128 patients were enrolled in this study and were randomly assigned to either the TP group (64 patients) or the OI group (64 patients), and DB ACL reconstructions were performed. At the minimum 2-year follow-up (34.9 ± 10.9 months), 111 patients (86.7%) were evaluated with multiple clinical scores and stability tests (KT-2000 arthrometer, Lachman test, and pivot-shift test). Ninety-three knees were evaluated for graft continuity, graft tension, and synovialization by use of second-look arthroscopy. Seventy-eight knees were evaluated on MRI for graft continuity, femoral graft tunnel healing, and graft signal/noise quotient (SNQ). The primary outcome was KT-2000 arthrometer results. Results were compared between the TP and OI groups. No significant differences were found between the 2 groups in terms of KT-2000 arthrometer results, which was the primary outcome, and other clinical results, with the exception of the postoperative functional test of International Knee Documentation Committee (IKDC) objective score. The ratio of grade A and B on the postoperative functional test of IKDC objective score was significantly larger for the OI group (51/58) than the TP group (36/53) ( P = .005). The second-look arthroscopic findings were not significantly different between the 2 groups in either bundle ( P > .05). In addition, MRI findings did not differ significantly between the 2 groups ( P > .05). With the exception of the functional test of IKDC objective score, we found that clinical results, second-look arthroscopic findings, and MRI findings did not differ significantly between the OI and TP techniques for anatomic ACL reconstruction, although femoral tunnel geometries differed significantly between the 2 techniques.

  12. SRB Environment Evaluation and Analysis. Volume 2: RSRB Joint Filling Test/Analysis Improvements

    NASA Technical Reports Server (NTRS)

    Knox, E. C.; Woods, G. Hamilton

    1991-01-01

    Following the Challenger accident a very comprehensive solid rocket booster (SRB) redesign program was initiated. One objective of the program was to develop expertise at NASA/MSFC in the techniques for analyzing the flow of hot gases in the SRB joints. Several test programs were undertaken to provide a data base of joint performance with manufactured defects in the joints to allow hot gases to fill the joints. This data base was used also to develop the analytical techniques. Some of the test programs were Joint Environment Simulator (JES), Nozzle Joint Environment Simulator (NJES), Transient Pressure Test Article (TPTA), and Seventy-Pound Charge (SPC). In 1988 the TPTA test hardware was moved from the Utah site to MSFC and several RSRM tests were scheduled, to be followed by tests for the ASRM program. REMTECH Inc. supported these activities with pretest estimates of the flow conditions in the test joints, and post-test analysis and evaluation of the measurements. During this support REMTECH identified deficiencies in the gas-measurement instrumentation that existed in the TPTA hardware, made recommendations for its replacement, and identified improvements to the analytical tools used in the test support. Only one test was completed under the TPTA RSRM test program, and those scheduled for the ASRM were rescheduled to a time after the expiration of this contract. The attention of this effort was directed toward improvements in the analytical techniques in preparation for when the ASRM program begins.

  13. Missile airframe simulation testbed: MANPADS (MAST-M) for test and evaluation of aircraft survivability equipment

    NASA Astrophysics Data System (ADS)

    Clements, Jim; Robinson, Richard; Bunt, Leslie; Robinson, Joe

    2011-06-01

    A number of techniques have been utilized to evaluate the performance of Aircraft Survivability Equipment (ASE) against threat Man-Portable Air Defense Systems (MANPADS). These techniques include flying actual threat MANPADS against stationary ASE with simulated aircraft signatures, testing installed ASE systems against simulated threat signatures, and laboratory hardware-in-the-loop (HWIL) testing with simulated aircraft and simulated missile signatures. All of these tests lack the realism of evaluating installed ASE against in-flight MANPADS on a terminal homing intercept path toward the actual ASE equipped aircraft. This limitation is due primarily to the current inability to perform non-destructive MANPADS/Aircraft flight testing. The U.S. Army Aviation and Missile Research and Development and Engineering Center (AMRDEC) is working to overcome this limitation with the development of a recoverable surrogate MANPADS missile system capable of engaging aircraft equipped with ASE while guaranteeing collision avoidance with the test aircraft. Under its Missile Airframe Simulation Testbed - MANPADS (MAST-M) program, the AMRDEC is developing a surrogate missile system which will utilize actual threat MANPADS seeker/guidance sections to control the flight of a surrogate missile which will perform a collision avoidance and recovery maneuver prior to intercept to insure non-destructive test and evaluation of the ASE and reuse of the MANPADS seeker/guidance section. The remainder of this paper provides an overview of this development program and intended use.

  14. Propensity Score Techniques and the Assessment of Measured Covariate Balance to Test Causal Associations in Psychological Research

    ERIC Educational Resources Information Center

    Harder, Valerie S.; Stuart, Elizabeth A.; Anthony, James C.

    2010-01-01

    There is considerable interest in using propensity score (PS) statistical techniques to address questions of causal inference in psychological research. Many PS techniques exist, yet few guidelines are available to aid applied researchers in their understanding, use, and evaluation. In this study, the authors give an overview of available…

  15. Results of NDE Technique Evaluation of Clad Hydrides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kunerth, Dennis C.

    2014-09-01

    This report fulfills the M4 milestone, M4FT-14IN0805023, Results of NDE Technique Evaluation of Clad Hydrides, under Work Package Number FT-14IN080502. During service, zirconium alloy fuel cladding will degrade via corrosion/oxidation. Hydrogen, a byproduct of the oxidation process, will be absorbed into the cladding and eventually form hydrides due to low hydrogen solubility limits. The hydride phase is detrimental to the mechanical properties of the cladding and therefore it is important to be able to detect and characterize the presence of this constituent within the cladding. Presently, hydrides are evaluated using destructive examination. If nondestructive evaluation techniques can be used tomore » detect and characterize the hydrides, the potential exists to significantly increase test sample coverage while reducing evaluation time and cost. To demonstrate the viability this approach, an initial evaluation of eddy current and ultrasonic techniques were performed to demonstrate the basic ability to these techniques to detect hydrides or their effects on the microstructure. Conventional continuous wave eddy current techniques were applied to zirconium based cladding test samples thermally processed with hydrogen gas to promote the absorption of hydrogen and subsequent formation of hydrides. The results of the evaluation demonstrate that eddy current inspection approaches have the potential to detect both the physical damage induced by hydrides, e.g. blisters and cracking, as well as the combined effects of absorbed hydrogen and hydride precipitates on the electrical properties of the zirconium alloy. Similarly, measurements of ultrasonic wave velocities indicate changes in the elastic properties resulting from the combined effects of absorbed hydrogen and hydride precipitates as well as changes in geometry in regions of severe degradation. However, for both approaches, the signal responses intended to make the desired measurement incorporate a number of contributing parameters. These contributing factors need to be recognized and a means to control them or separate their contributions will be required to obtain the desired information.« less

  16. Evaluating the event-related synchronization and desynchronization by means of a statistical frequency test.

    PubMed

    Miranda de Sá, Antonio Mauricio F L; Infantosi, Antonio Fernando C; Lazarev, Vladimir V

    2007-01-01

    In the present work, a commonly used index for evaluating the Event-Related Synchronization and Desynchronization (ERS/ERD) in the EEG was expressed as a function of the Spectral F-Test (SFT), which is a statistical test for assessing if two sample spectra are from populations with identical theoretical spectra. The sampling distribution of SFT has been derived, allowing hence ERS/ERD to be evaluated under a statistical basis. An example of the technique was also provided in the EEG signals from 10 normal subjects during intermittent photic stimulation.

  17. Development of Advanced Thermal and Environmental Barrier Coatings Using a High-Heat-Flux Testing Approach

    NASA Technical Reports Server (NTRS)

    Zhu, Dongming; Miller, Robert A.

    2003-01-01

    The development of low conductivity, robust thermal and environmental barrier coatings requires advanced testing techniques that can accurately and effectively evaluate coating thermal conductivity and cyclic resistance at very high surface temperatures (up to 1700 C) under large thermal gradients. In this study, a laser high-heat-flux test approach is established for evaluating advanced low conductivity, high temperature capability thermal and environmental barrier coatings under the NASA Ultra Efficient Engine Technology (UEET) program. The test approach emphasizes the real-time monitoring and assessment of the coating thermal conductivity, which initially rises under the steady-state high temperature thermal gradient test due to coating sintering, and later drops under the cyclic thermal gradient test due to coating cracking/delamination. The coating system is then evaluated based on damage accumulation and failure after the combined steady-state and cyclic thermal gradient tests. The lattice and radiation thermal conductivity of advanced ceramic coatings can also be evaluated using laser heat-flux techniques. The external radiation resistance of the coating is assessed based on the measured specimen temperature response under a laser- heated intense radiation-flux source. The coating internal radiation contribution is investigated based on the measured apparent coating conductivity increases with the coating surface test temperature under large thermal gradient test conditions. Since an increased radiation contribution is observed at these very high surface test temperatures, by varying the laser heat-flux and coating average test temperature, the complex relation between the lattice and radiation conductivity as a function of surface and interface test temperature may be derived.

  18. Primary Water Stress Corrosion Cracks in Nickel Alloy Dissimilar Metal Welds: Detection and Sizing Using Established and Emerging Nondestructive Examination Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Braatz, Brett G.; Cumblidge, Stephen E.; Doctor, Steven R.

    2012-12-31

    The U.S. Nuclear Regulatory Commission has established the Program to Assess the Reliability of Emerging Nondestructive Techniques (PARENT) as a follow-on to the international cooperative Program for the Inspection of Nickel Alloy Components (PINC). The goal of PINC was to evaluate the capabilities of various nondestructive evaluation (NDE) techniques to detect and characterize surface-breaking primary water stress corrosion cracks in dissimilar-metal welds (DMW) in bottom-mounted instrumentation (BMI) penetrations and small-bore (≈400-mm diameter) piping components. A series of international blind round-robin tests were conducted by commercial and university inspection teams. Results from these tests showed that a combination of conventional andmore » phased-array ultrasound techniques provided the highest performance for flaw detection and depth sizing in dissimilar metal piping welds. The effective detection of flaws in BMIs by eddy current and ultrasound shows that it may be possible to reliably inspect these components in the field. The goal of PARENT is to continue the work begun in PINC and apply the lessons learned to a series of open and blind international round-robin tests that will be conducted on a new set of piping components including large-bore (≈900-mm diameter) DMWs, small-bore DMWs, and BMIs. Open round-robin testing will engage universities and industry worldwide to investigate the reliability of emerging NDE techniques to detect and accurately size flaws having a wide range of lengths, depths, orientations, and locations. Blind round-robin testing will invite testing organizations worldwide, whose inspectors and procedures are certified by the standards for the nuclear industry in their respective countries, to investigate the ability of established NDE techniques to detect and size flaws whose characteristics range from easy to very difficult to detect and size. This paper presents highlights of PINC and reports on the plans and progress for PARENT round-robin tests.« less

  19. Evaluation of acoustic testing techniques for spacecraft systems

    NASA Technical Reports Server (NTRS)

    Cockburn, J. A.

    1971-01-01

    External acoustic environments, structural responses, noise reductions, and the internal acoustic environments have been predicted for a typical shroud/spacecraft system during lift-off and various critical stages of flight. Spacecraft responses caused by energy transmission from the shroud via mechanical and acoustic paths have been compared and the importance of the mechanical path has been evaluated. Theoretical predictions have been compared extensively with available laboratory and in-flight measurements. Equivalent laboratory acoustic fields for simulation of shroud response during the various phases of flight have been derived and compared in detail. Techniques for varying the time-space correlations of laboratory acoustic fields have been examined, together with methods for varying the time and spatial distribution of acoustic amplitudes. Possible acoustic testing configurations for shroud/spacecraft systems have been suggested and trade-off considerations have been reviewed. The problem of simulating the acoustic environments versus simulating the structural responses has been considered and techniques for testing without the shroud installed have been discussed.

  20. Evaluation of small area crop estimation techniques using LANDSAT- and ground-derived data. [South Dakota

    NASA Technical Reports Server (NTRS)

    Amis, M. L.; Martin, M. V.; Mcguire, W. G.; Shen, S. S. (Principal Investigator)

    1982-01-01

    Studies completed in fiscal year 1981 in support of the clustering/classification and preprocessing activities of the Domestic Crops and Land Cover project. The theme throughout the study was the improvement of subanalysis district (usually county level) crop hectarage estimates, as reflected in the following three objectives: (1) to evaluate the current U.S. Department of Agriculture Statistical Reporting Service regression approach to crop area estimation as applied to the problem of obtaining subanalysis district estimates; (2) to develop and test alternative approaches to subanalysis district estimation; and (3) to develop and test preprocessing techniques for use in improving subanalysis district estimates.

  1. Efficient field testing for load rating railroad bridges

    NASA Astrophysics Data System (ADS)

    Schulz, Jeffrey L.; Brett C., Commander

    1995-06-01

    As the condition of our infrastructure continues to deteriorate, and the loads carried by our bridges continue to increase, an ever growing number of railroad and highway bridges require load limits. With safety and transportation costs at both ends of the spectrum. the need for accurate load rating is paramount. This paper describes a method that has been developed for efficient load testing and evaluation of short- and medium-span bridges. Through the use of a specially-designed structural testing system and efficient load test procedures, a typical bridge can be instrumented and tested at 64 points in less than one working day and with minimum impact on rail traffic. Various techniques are available to evaluate structural properties and obtain a realistic model. With field data, a simple finite element model is 'calibrated' and its accuracy is verified. Appropriate design and rating loads are applied to the resulting model and stress predictions are made. This technique has been performed on numerous structures to address specific problems and to provide accurate load ratings. The merits and limitations of this approach are discussed in the context of actual examples of both rail and highway bridges that were tested and evaluated.

  2. 10.3 High-temperature Instrumentation

    NASA Technical Reports Server (NTRS)

    Piazza, Anthony

    2008-01-01

    This viewgraph presentation describes high temperature instrumentation development from 1960-1970, 1980-1990 and 2000-present. The contents include: 1) Background; 2) Objective; 3) Application and Sensor; 4) Attachment Techniques; 5) Evaluation/Characterization Testing; and 6) Future testing.

  3. Flight selection at United Airlines

    NASA Technical Reports Server (NTRS)

    Traub, W.

    1980-01-01

    Airline pilot selection proceedures are discussed including psychogical and personality tests, psychomotor performance requirements, and flight skills evaluation. Necessary attitude and personality traits are described and an outline of computer selection, testing, and training techniques is given.

  4. FIELD ASSESSMENT OF MULTIPLE DNAPL REMEDIATION TECHNIQUES

    EPA Science Inventory

    Five DNAPL remediation technologies were evaluated in constructed test cells at the Dover National Test Site, Dover AFB, Delaware. The technologies were cosolvent solubilization, cosolvent mobilization, surfactant solubilization, complex sugar flushing and air sparging/soil vapor...

  5. In vitro evaluation of marginal adaptation in five ceramic restoration fabricating techniques.

    PubMed

    Ural, Cağri; Burgaz, Yavuz; Saraç, Duygu

    2010-01-01

    To compare in vitro the marginal adaptation of crowns manufactured using ceramic restoration fabricating techniques. Fifty standardized master steel dies simulating molars were produced and divided into five groups, each containing 10 specimens. Test specimens were fabricated with CAD/CAM, heat-press, glass-infiltration, and conventional lost-wax techniques according to manufacturer instructions. Marginal adaptation of the test specimens was measured vertically before and after cementation using SEM. Data were statistically analyzed by one-way ANOVA with Tukey HSD tests (a = .05). Marginal adaptation of ceramic crowns was affected by fabrication technique and cementation process (P < .001). The lowest marginal opening values were obtained with Cerec-3 crowns before and after cementation (P < .001). The highest marginal discrepancy values were obtained with PFM crowns before and after cementation. Marginal adaptation values obtained in the compared systems were within clinically acceptable limits. Cementation causes a significant increase in the vertical marginal discrepancies of the test specimens.

  6. Prospective Study of the Surgical Techniques Used in Primary Rhinoplasty on the Caucasian Nose and Comparison of the Preoperative and Postoperative Anthropometric Nose Measurements

    PubMed Central

    Berger, Cezar Augusto Sarraf; Freitas, Renato da Silva; Malafaia, Osvaldo; Pinto, José Simão de Paula; Macedo Filho, Evaldo Dacheux; Mocellin, Marcos; Fagundes, Marina Serrato Coelho

    2014-01-01

    Introduction The knowledge and study of surgical techniques and anthropometric measurements of the nose make possible a qualitative and quantitative analysis of surgical results. Objective Study the main technique used in rhinoplasty on Caucasian noses and compare preoperative and postoperative anthropometric measurements of the nose. Methods A prospective study with 170 patients was performed at a private hospital. Data were collected using the Electronic System Integrated of Protocols software (Sistema Integrado de Protocolos Eletrônicos, SINPE©). The surgical techniques used in the nasal dorsum and tip were evaluated. Preoperative and 12-month follow-up photos as well as the measurements compared with the ideal aesthetic standard of a Caucasian nose were analyzed objectively. Student t test and standard deviation test were applied. Results There was a predominance of endonasal access (94.4%). The most common dorsum technique was hump removal (33.33%), and the predominance of sutures (24.76%) was observed on the nasal tip, with the lateral intercrural the most frequent (32.39%). Comparison between preoperative and postoperative photos found statistically significant alterations on the anthropometric measurements of the noses. Conclusion The main surgical techniques on Caucasian noses were evaluated, and a great variety was found. The evaluation of anthropometric measurements of the nose proved the efficiency of the performed procedures. PMID:25992149

  7. A small punch test technique for characterizing the elastic modulus and fracture behavior of PMMA bone cement used in total joint replacement.

    PubMed

    Giddings, V L; Kurtz, S M; Jewett, C W; Foulds, J R; Edidin, A A

    2001-07-01

    Polymethylmethacrylate (PMMA) bone cement is used in total joint replacements to anchor implants to the underlying bone. Establishing and maintaining the integrity of bone cement is thus of critical importance to the long-term outcome of joint replacement surgery. The goal of the present study was to evaluate the suitability of a novel testing technique, the small punch or miniaturized disk bend test, to characterize the elastic modulus and fracture behavior of PMMA. We investigated the hypothesis that the crack initiation behavior of PMMA during the small punch test was sensitive to the test temperature. Miniature disk-shaped specimens, 0.5 mm thick and 6.4 mm in diameter, were prepared from PMMA and Simplex-P bone cement according to manufacturers' instructions. Testing was conducted at ambient and body temperatures, and the effect of test temperature on the elastic modulus and fracture behavior was statistically evaluated using analysis of variance. For both PMMA materials, the test temperature had a significant effect on elastic modulus and crack initiation behavior. At body temperature, the specimens exhibited "ductile" crack initiation, whereas at room temperature "brittle" crack initiation was observed. The small punch test was found to be a sensitive and repeatable test method for evaluating the mechanical behavior of PMMA. In light of the results of this study, future small punch testing should be conducted at body temperature.

  8. Evaluating Equating Results in the Non-Equivalent Groups with Anchor Test Design Using Equipercentile and Equity Criteria

    ERIC Educational Resources Information Center

    Duong, Minh Quang

    2011-01-01

    Testing programs often use multiple test forms of the same test to control item exposure and to ensure test security. Although test forms are constructed to be as similar as possible, they often differ. Test equating techniques are those statistical methods used to adjust scores obtained on different test forms of the same test so that they are…

  9. Evaluation of Primary Immunization Coverage of Infants Under Universal Immunization Programme in an Urban Area of Bangalore City Using Cluster Sampling and Lot Quality Assurance Sampling Techniques

    PubMed Central

    K, Punith; K, Lalitha; G, Suman; BS, Pradeep; Kumar K, Jayanth

    2008-01-01

    Research Question: Is LQAS technique better than cluster sampling technique in terms of resources to evaluate the immunization coverage in an urban area? Objective: To assess and compare the lot quality assurance sampling against cluster sampling in the evaluation of primary immunization coverage. Study Design: Population-based cross-sectional study. Study Setting: Areas under Mathikere Urban Health Center. Study Subjects: Children aged 12 months to 23 months. Sample Size: 220 in cluster sampling, 76 in lot quality assurance sampling. Statistical Analysis: Percentages and Proportions, Chi square Test. Results: (1) Using cluster sampling, the percentage of completely immunized, partially immunized and unimmunized children were 84.09%, 14.09% and 1.82%, respectively. With lot quality assurance sampling, it was 92.11%, 6.58% and 1.31%, respectively. (2) Immunization coverage levels as evaluated by cluster sampling technique were not statistically different from the coverage value as obtained by lot quality assurance sampling techniques. Considering the time and resources required, it was found that lot quality assurance sampling is a better technique in evaluating the primary immunization coverage in urban area. PMID:19876474

  10. Comparative Evaluation of Conventional and Accelerated Castings on Marginal Fit and Surface Roughness

    PubMed Central

    Jadhav, Vivek Dattatray; Motwani, Bhagwan K.; Shinde, Jitendra; Adhapure, Prasad

    2017-01-01

    Aims: The aim of this study was to evaluate the marginal fit and surface roughness of complete cast crowns made by a conventional and an accelerated casting technique. Settings and Design: This study was divided into three parts. In Part I, the marginal fit of full metal crowns made by both casting techniques in the vertical direction was checked, in Part II, the fit of sectional metal crowns in the horizontal direction made by both casting techniques was checked, and in Part III, the surface roughness of disc-shaped metal plate specimens made by both casting techniques was checked. Materials and Methods: A conventional technique was compared with an accelerated technique. In Part I of the study, the marginal fit of the full metal crowns as well as in Part II, the horizontal fit of sectional metal crowns made by both casting techniques was determined, and in Part III, the surface roughness of castings made with the same techniques was compared. Statistical Analysis Used: The results of the t-test and independent sample test do not indicate statistically significant differences in the marginal discrepancy detected between the two casting techniques. Results: For the marginal discrepancy and surface roughness, crowns fabricated with the accelerated technique were significantly different from those fabricated with the conventional technique. Conclusions: Accelerated casting technique showed quite satisfactory results, but the conventional technique was superior in terms of marginal fit and surface roughness. PMID:29042726

  11. Comparative evaluation of the results of three techniques in the reconstruction of the anterior cruciate ligament, with a minimum follow-up of two years.

    PubMed

    Cury, Ricardo de Paula Leite; Sprey, Jan Willem Cerf; Bragatto, André Luiz Lima; Mansano, Marcelo Valentim; Moscovici, Herman Fabian; Guglielmetti, Luiz Gabriel Betoni

    2017-01-01

    To compare the clinical results of the reconstruction of the anterior cruciate ligament by transtibial, transportal, and outside-in techniques. This was a retrospective study on 90 patients (ACL reconstruction with autologous flexor tendons) operated between August 2009 and June 2012, by the medial transportal (30), transtibial (30), and "outside-in" (30) techniques. The following parameters were assessed: objective and subjective IKDC, Lysholm, KT1000, Lachman test, Pivot-Shift and anterior drawer test. On physical examination, the Lachman test and Pivot-Shift indicated a slight superiority of the outside-in technique, but without statistical significance ( p  = 0.132 and p  = 0.186 respectively). The anterior drawer, KT1000, subjective IKDC, Lysholm, and objective IKDC tests showed similar results in the groups studied. A higher number of complications were observed in the medial transportal technique ( p  = 0.033). There were no statistically significant differences in the clinical results of patients undergoing reconstruction of the anterior cruciate ligament by transtibial, medial transportal, and outside-in techniques.

  12. Rapid Salmonella detection in experimentally inoculated equine faecal and veterinary hospital environmental samples using commercially available lateral flow immunoassays.

    PubMed

    Burgess, B A; Noyes, N R; Bolte, D S; Hyatt, D R; van Metre, D C; Morley, P S

    2015-01-01

    Salmonella enterica is the most commonly reported cause of outbreaks of nosocomial infections in large animal veterinary teaching hospitals and the closure of equine hospitals. Rapid detection may facilitate effective control practices in equine populations. Shipping and laboratory testing typically require ≥48 h to obtain results. Lateral flow immunoassays developed for use in food-safety microbiology provide an alternative that has not been evaluated for use with faeces or environmental samples. We aimed to identify enrichment methods that would allow commercially available rapid Salmonella detection systems (lateral flow immunoassays) to be used in clinical practice with equine faecal and environmental samples, providing test results in 18-24 h. In vitro experiment. Equine faecal and environmental samples were inoculated with known quantities of S. enterica serotype Typhimurium and cultured using 2 different enrichment techniques for faeces and 4 enrichment techniques for environmental samples. Samples were tested blindly using 2 different lateral flow immunoassays and plated on agar media for confirmatory testing. In general, commercial lateral flow immunoassays resulted in fewer false-negative test results with enrichment of 1 g faecal samples in tetrathionate for 18 h, while all environmental sample enrichment techniques resulted in similar detection rates. The limit of detection from spiked samples, ∼4 colony-forming units/g, was similar for all methods evaluated. The lateral flow immunoassays evaluated could reliably detect S. enterica within 18 h, indicating that they may be useful for rapid point-of-care testing in equine practice applications. Additional evaluation is needed using samples from naturally infected cases and the environment to gain an accurate estimate of test sensitivity and specificity and to substantiate further the true value of these tests in clinical practice. © 2014 EVJ Ltd.

  13. The development of in situ fracture toughness evaluation techniques in hydrogen environment

    DOE PAGES

    Wang, John Jy-An; Ren, Fei; Tan, Tin; ...

    2014-12-19

    Reliability of hydrogen pipelines and storage tanks is significantly influenced by the mechanical performance of the structural materials exposed in the hydrogen environment. Fracture behavior and fracture toughness are of specific interest since they are relevant to many catastrophic failures. However, many conventional fracture testing techniques are difficult to be realized under the presence of hydrogen. Thus it is desired to develop novel in situ techniques to study the fracture behavior of structural materials in hydrogen environments. In this study, special testing apparatus were designed to facilitate in situ fracture testing in H 2. A torsional fixture was developed tomore » utilize an emerging fracture testing technique, Spiral Notch Torsion Test (SNTT). The design concepts will be discussed. Preliminary in situ testing results indicated that the exposure to H 2 significantly reduces the fracture toughness of 4340 high strength steels by up to 50 percent. Furthermore, SNTT tests conducted in air demonstrated a significant fracture toughness reduction in samples subject to simulated welding heat treatment using Gleeble, which illustrated the effect of welding on the fracture toughness of this material.« less

  14. Utilization of Emotional Freedom Techniques (EFT) to Reduce Test Anxiety in High Stakes Testing

    ERIC Educational Resources Information Center

    Mohler, Marie Elaine

    2013-01-01

    There are many reasons a person may fail a high stakes test such as the National Council Licensure Examination for Registered Nurses (NCLEX-RN®). Sleep deprivation, illness, life stressors, knowledge deficit, and test anxiety are some of the common explanations. A student with test anxiety may feel threatened by this evaluation process. This…

  15. Nondestructive testing of Scout rocket motors

    NASA Technical Reports Server (NTRS)

    Oaks, A. E.

    1972-01-01

    The nondestructive tests applied to Scout rocket motors were reviewed and appraised. Analytical techniques were developed to evaluate the capabilities of the radiographic and ultrasonic procedures used. Major problem areas found were the inadequacy of high voltage radiography for detecting unbonds and propellant cracks having narrow widths, the inability to relate the ultrasonic signals received from flat-bottomed holes in standards to those received from real defects and in the general area of the specification of acceptance criteria and how these were to be met. To counter the deficiencies noted, analyses were conducted to the potential utility of radiometric, acoustic, holographic and thermographic techniques for motor and nozzle bond inspection, a new approach to qualifying magnetic particle inspection and the application of acoustic emission analysis to the evaluation of proof and leak test data.

  16. Evaluation of modified Dennis parasitological technique for diagnosis of bovine fascioliasis.

    PubMed

    Correa, Stefanya; Martínez, Yudy Liceth; López, Jessika Lissethe; Velásquez, Luz Elena

    2016-02-23

    Bovine fascioliasis causes important economic losses, estimated at COP$ 12,483 billion per year; its prevalence is 25% in dairy cattle. Parasitological techniques are required for it diagnosis. The Dennis technique, modified in 2002, is the one used in Colombia, but its sensitivity, specificity and validity are not known.  To evaluate the validity and performance of the modified Dennis technique for diagnosis of bovine fascioliasis using as reference test the observation of parasites in the liver.  We conducted a diagnostic evaluation study. We selected a convenience sample of discarded bovines sacrificed between March and June, 2013, in Frigocolanta for the study. We collected 25 g of feces from each animal and their liver and bile ducts were examined for Fasciola hepatica. The sensitivity, specificity, predictive positive value, predictive negative value, and validity index were calculated with 95% confidence intervals. The post-mortem evaluation was used as the gold standard.  We analyzed 180 bovines. The sensitivity and specificity of the modified Dennis technique were 73.2% (95% CI=58.4% - 87.9%) and 84.2% (95% CI= 77.7% - 90.6%), respectively. The positive predictive value was 57.7% (95% CI= 43.3% - 72.1%) and the negative one 91.4% (95% CI= 86.2% - 96.6%). The prevalence of bovine fascioliasis was 22.8% (95% CI= 16.4% - 29.2%).  The validity and the performance of the modified Dennis technique were higher than those of the traditional one, which makes it a good screening test for diagnosing fascioliasis for population and prevalence studies and during animal health campaigns.

  17. F/A-18 forebody vortex control. Volume 2: Rotary-balance tests

    NASA Technical Reports Server (NTRS)

    Kramer, Brian R.; Suarez, Carlos J.; Malcolm, Gerald N.; Ayers, Bert F.

    1994-01-01

    A rotary-balance wind tunnel test was conducted on a six percent model of the F/A-18 at the NASA Ames 7 X 10-Foot Low Speed Wind Tunnel. The data reduction was specially written for the test in National Instruments' LabVIEW. The data acquisition, reduction and analysis was performed with a Macintosh computer. The primary objective of the test was to evaluate the effectiveness of several forebody vortex control configurations in a rotary flow field. The devices that were found to be the most effective during the static tests (Volume 1) were investigated and included both mechanical and pneumatic configurations. The mechanical systems evaluated were small, single and dual, rotating nose tip strakes and a vertical nose strake. The jet blowing configuration used nozzles canted inboard 60 degrees. A two segment tangential slot was also evaluated. The different techniques were evaluated at angles of attack of 30 degrees, 45 degrees, 51 degrees, and 60 degrees. Sideslip and Reynolds number were varied for some of the configurations. All of the techniques proved to be effective in the rotating flow field. The vertical nose strake had the largest 'envelope' of effectiveness. Forebody vortex control provides large, robust yawing moments at medium to high angles of attack, even during combat maneuvers such as loaded roll.

  18. A 6-month comparative clinical study of a conventional and a new surgical approach for root coverage with acellular dermal matrix.

    PubMed

    Barros, Raquel R M; Novaes, Arthur B Júnior; Grisi, Márcio F M; Souza, Sérgio L S; Taba, Mário Júnior; Palioto, Daniela B

    2004-10-01

    The acellular dermal matrix graft (ADMG) has become widely used in periodontal surgeries as a substitute for the subepithelial connective tissue graft (SCTG). These grafts exhibit different healing processes due to their distinct cellular and vascular structures. Therefore the surgical technique primarily developed for the autograft may not be adequate for the allograft. This study compared the clinical results of two surgical techniques--the "conventional" and a modified procedure--for the treatment of localized gingival recessions with the ADMG. A total of 32 bilateral Miller Class I or II gingival recessions were selected and randomly assigned to test and control groups. The control group received the SCTG and the test group the modified surgical technique. Probing depth (PD), relative clinical attachment level (RCAL), gingival recession (GR), and width of keratinized tissue (KT) were measured 2 weeks prior to surgery and 6 months post-surgery. Both procedures improved all the evaluated parameters after 6 months. Comparisons between the groups by Mann-Whitney rank sum test revealed no statistically significant differences in terms of CAL gain, PD reduction, and increase in KT from baseline to 6-month evaluation. However, there was a statistically significant greater reduction of GR favoring the modified technique (P = 0.002). The percentage of root coverage was 79% for the test group and 63.9% for the control group. We conclude that the modified technique is more suitable for root coverage procedures with the ADMG since it had statistically significant better clinical results compared to the traditional technique.

  19. PARENT Quick Blind Round-Robin Test Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Braatz, Brett G.; Heasler, Patrick G.; Meyer, Ryan M.

    The U.S. Nuclear Regulatory Commission has established the Program to Assess the Reliability of Emerging Nondestructive Techniques (PARENT) whose goal is to investigate the effectiveness of current and novel nondestructive examination procedures and techniques to find flaws in nickel-alloy welds and base materials. This is to be done by conducting a series of open and blind international round-robin tests on a set of piping components that include large-bore dissimilar metal welds, small-bore dissimilar metal welds, and bottom-mounted instrumentation penetration welds. The blind testing is being conducted in two segments, one is called Quick-Blind and the other is called Blind. Themore » Quick-Blind testing and destructive analysis of the test blocks has been completed. This report describes the four Quick-Blind test blocks used, summarizes their destructive analysis, gives an overview of the nondestructive evaluation (NDE) techniques applied, provides an analysis inspection data, and presents the conclusions drawn.« less

  20. Laboratory evaluation of alcohol safety interlock systems. Volume 1 : summary report

    DOT National Transportation Integrated Search

    1974-01-01

    The report contains the results of an experimental and analytical evaluation of instruments and techniques designed to prevent an intoxicated driver from operating his automobile. The prototype 'Alcohol Safety Interlock Systems' tested were developed...

  1. Reproducibility of an objective four-choice canine vision testing technique that assesses vision at differing light intensities.

    PubMed

    Annear, Matthew J; Gornik, Kara R; Venturi, Francesca L; Hauptman, Joe G; Bartoe, Joshua T; Petersen-Jones, Simon M

    2013-09-01

    The increasing importance of canine retinal dystrophy models means accurate vision testing is needed. This study was performed to evaluate a four-choice vision testing technique for any difference in outcome measures with repeated evaluations of the same dogs.   Four 11-month-old RPE65-deficient dogs. Vision was evaluated using a previously described four-choice vision testing device. Four evaluations were performed at 2-week intervals. Vision was assessed at six different white light intensities (bright through dim), and each eye was evaluated separately. The ability to select the one of the four exit tunnels that was open at the far end was assessed ('choice of exit') and recorded as correct or incorrect first tunnel choice. 'Time to exit' the device was also recorded. Both outcomes were analyzed for significance using anova. We hypothesized that performance would improve with repeated testing (more correct choices and more rapid time to exit). 'Choice of exit' did not vary significantly between each evaluation (P = 0.12), in contrast 'time to exit' increased significantly (P = 0.012), and showed greater variability in dim light conditions. We found no evidence to support the hypothesis that either measure of outcome worsened with repeated testing; in fact, the 'time to exit' outcome worsened rather than improved. The 'choice of exit' gave consistent results between trials. These outcome data indicate the importance of including a choice-based assessment of vision in addition to measurement of device transit time. © 2012 American College of Veterinary Ophthalmologists.

  2. EVALUATION OF A DNA PROBE TEST KIT FOR DETECTION OF SALMONELLAE IN BIOSOLIDS

    EPA Science Inventory

    Aims: Current United States regulations (40 CFR 503) for "Class A" biosolids requires use of multiple-tube fermentation techniques for fecal coliform or multiple tube enrichment techniques for Salmonella spp. followed by isolation and biochemical and serological confirmation. T...

  3. Development of an external ceramic insulation for the space shuttle orbiter

    NASA Technical Reports Server (NTRS)

    Tanzilli, R. A. (Editor)

    1972-01-01

    The development and evaluation of a family of reusable external insulation systems for use on the space shuttle orbiter is discussed. The material development and evaluation activities are described. Additional information is provided on the development of an analytical micromechanical model of the reusable insulation and the development of techniques for reducing the heat transfer. Design data on reusable insulation systems and test techniques used for design data generation are included.

  4. Blasting Rocks and Blasting Cars: Applied Engineering (LBNL Summer Lecture Series)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hopkins, Deborah

    2004-06-30

    Summer Lecture Series 2004: Deb Hopkins works with industries like automobile, mining and paper to improve their evaluation and measuring techniques. For several years, she has coordinated a program at Berkeley Lab funded under the Partnership for a New Generation of Vehicles, a collaboration between the federal government and the U.S. Council for Automotive Research. Nondestructive evaluation techniques to test a car's structural integrity are being developed for auto assembly lines.

  5. Blasting Rocks and Blasting Cars: Applied Engineering (LBNL Summer Lecture Series)

    ScienceCinema

    Hopkins, Deborah [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Engineering Division

    2017-12-09

    Summer Lecture Series 2004: Deb Hopkins works with industries like automobile, mining and paper to improve their evaluation and measuring techniques. For several years, she has coordinated a program at Berkeley Lab funded under the Partnership for a New Generation of Vehicles, a collaboration between the federal government and the U.S. Council for Automotive Research. Nondestructive evaluation techniques to test a car's structural integrity are being developed for auto assembly lines.

  6. Privacy-preserving genome-wide association studies on cloud environment using fully homomorphic encryption.

    PubMed

    Lu, Wen-Jie; Yamada, Yoshiji; Sakuma, Jun

    2015-01-01

    Developed sequencing techniques are yielding large-scale genomic data at low cost. A genome-wide association study (GWAS) targeting genetic variations that are significantly associated with a particular disease offers great potential for medical improvement. However, subjects who volunteer their genomic data expose themselves to the risk of privacy invasion; these privacy concerns prevent efficient genomic data sharing. Our goal is to presents a cryptographic solution to this problem. To maintain the privacy of subjects, we propose encryption of all genotype and phenotype data. To allow the cloud to perform meaningful computation in relation to the encrypted data, we use a fully homomorphic encryption scheme. Noting that we can evaluate typical statistics for GWAS from a frequency table, our solution evaluates frequency tables with encrypted genomic and clinical data as input. We propose to use a packing technique for efficient evaluation of these frequency tables. Our solution supports evaluation of the D' measure of linkage disequilibrium, the Hardy-Weinberg Equilibrium, the χ2 test, etc. In this paper, we take χ2 test and linkage disequilibrium as examples and demonstrate how we can conduct these algorithms securely and efficiently in an outsourcing setting. We demonstrate with experimentation that secure outsourcing computation of one χ2 test with 10, 000 subjects requires about 35 ms and evaluation of one linkage disequilibrium with 10, 000 subjects requires about 80 ms. With appropriate encoding and packing technique, cryptographic solutions based on fully homomorphic encryption for secure computations of GWAS can be practical.

  7. Reverse Engineering Crosswind Limits - A New Flight Test Technique?

    NASA Technical Reports Server (NTRS)

    Asher, Troy A.; Willliams, Timothy L.; Strovers, Brian K.

    2013-01-01

    During modification of a Gulfstream III test bed aircraft for an experimental flap project, all roll spoiler hardware had to be removed to accommodate the test article. In addition to evaluating the effects on performance and flying qualities resulting from the modification, the test team had to determine crosswind limits for an airplane previously certified with roll spoilers. Predictions for the modified aircraft indicated the maximum amount of steady state sideslip available during the approach and landing phase would be limited by aileron authority rather than by rudder. Operating out of a location that tends to be very windy, an arbitrary and conservative wind limit would have either been overly restrictive or potentially unsafe if chosen poorly. When determining a crosswind limit, how much reserve roll authority was necessary? Would the aircraft, as configured, have suitable handling qualities for long-term use as a flying test bed? To answer these questions, the test team combined two typical flight test techniques into a new maneuver called the sideslip-to-bank maneuver, and was able to gather flying qualities data, evaluate aircraft response and measure trends for various crosswind scenarios. This paper will describe the research conducted, the maneuver, flight conditions, predictions, and results from this in-flight evaluation of crosswind capability.

  8. The effect of various veneering techniques on the marginal fit of zirconia copings.

    PubMed

    Torabi, Kianoosh; Vojdani, Mahroo; Giti, Rashin; Taghva, Masumeh; Pardis, Soheil

    2015-06-01

    This study aimed to evaluate the fit of zirconia ceramics before and after veneering, using 3 different veneering processes (layering, press-over, and CAD-on techniques). Thirty standardized zirconia CAD/CAM frameworks were constructed and divided into three groups of 10 each. The first group was veneered using the traditional layering technique. Press-over and CAD-on techniques were used to veneer second and third groups. The marginal gap of specimens was measured before and after veneering process at 18 sites on the master die using a digital microscope. Paired t-test was used to evaluate mean marginal gap changes. One-way ANOVA and post hoc tests were also employed for comparison among 3 groups (α=.05). Marginal gap of 3 groups was increased after porcelain veneering. The mean marginal gap values after veneering in the layering group (63.06 µm) was higher than press-over (50.64 µm) and CAD-on (51.50 µm) veneered groups (P<.001). Three veneering methods altered the marginal fit of zirconia copings. Conventional layering technique increased the marginal gap of zirconia framework more than pressing and CAD-on techniques. All ceramic crowns made through three different veneering methods revealed clinically acceptable marginal fit.

  9. Comparison between two surgical techniques for root coverage with an acellular dermal matrix graft.

    PubMed

    Andrade, Patrícia F; Felipe, Maria Emília M C; Novaes, Arthur B; Souza, Sérgio L S; Taba, Mário; Palioto, Daniela B; Grisi, Márcio F M

    2008-03-01

    The aim of this randomized, controlled, clinical study was to compare two surgical techniques with the acellular dermal matrix graft (ADMG) to evaluate which technique could provide better root coverage. Fifteen patients with bilateral Miller Class I gingival recession areas were selected. In each patient, one recession area was randomly assigned to the control group, while the contra-lateral recession area was assigned to the test group. The ADMG was used in both groups. The control group was treated with a broader flap and vertical-releasing incisions, and the test group was treated with the proposed surgical technique, without releasing incisions. The clinical parameters evaluated before the surgeries and after 12 months were: gingival recession height, probing depth, relative clinical attachment level and the width and thickness of keratinized tissue. There were no statistically significant differences between the groups for all parameters at baseline. After 12 months, there was a statistically significant reduction in recession height in both groups, and there was no statistically significant difference between the techniques with regard to root coverage. Both surgical techniques provided significant reduction in gingival recession height after 12 months, and similar results in relation to root coverage.

  10. Experimental investigations into cryosorption pumping of plasma exhaust

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perinic, D.; Mack, A.

    1988-09-01

    Within the framework of the European Fusion Technology Programme the Karlsruhe Nuclear Research Centre has been awarded a contract for the development of cryosorption panels for compound cryopumps of the NEt plasma exhaust pumping system. This task includes the development of a bonding technique for porous sorbent materials with metal substrates and a test programme for development and optimization of cryopanels. A variety of material combinations for sorbent, bonding and substrate were evaluated and listed in a test matrix. Bonding tests involving soldering, cementing and plasma spraying techniques have been carried out.

  11. Emulating a flexible space structure: Modeling

    NASA Technical Reports Server (NTRS)

    Waites, H. B.; Rice, S. C.; Jones, V. L.

    1988-01-01

    Control Dynamics, in conjunction with Marshall Space Flight Center, has participated in the modeling and testing of Flexible Space Structures. Through the series of configurations tested and the many techniques used for collecting, analyzing, and modeling the data, many valuable insights have been gained and important lessons learned. This paper discusses the background of the Large Space Structure program, Control Dynamics' involvement in testing and modeling of the configurations (especially the Active Control Technique Evaluation for Spacecraft (ACES) configuration), the results from these two processes, and insights gained from this work.

  12. The detection of fatigue cracks by nondestructive testing methods

    NASA Technical Reports Server (NTRS)

    Rummel, W. D.; Todd, P. H., Jr.; Frecska, S. A.; Rathke, R. A.

    1974-01-01

    X-radiographic penetrant, ultrasonic, eddy current, holographic, and acoustic emission techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens. One hundred eighteen specimens containing a total of 328 fatigue cracks were evaluated. The cracks ranged in length from 0.500 inch (1.27 cm) to 0.007 inch (0.018 cm) and in depth from 0.178 inch (0.451 cm) and 0.001 inch (0.003 cm). Specimen thicknesses were nominally 0.060 inch (0.152 cm) and 0.210 inch (0.532 cm) and surface finishes were nominally 32 and 125 rms and 64 and 200 rms respectively. Specimens were evaluated in the as-milled surface condition, in the chemically milled surface condition and, after proof loading, in a randomized inspection sequence. Results of the nondestructive test (NDT) evaluations were compared with actual crack size obtained by measurement of the fractured specimens. Inspection data was then analyzed to provide a statistical basis for determinating the threshold crack detection sensitivity (the largest crack size that would be missed) for each of the inspection techniques at a 95% probability and 95% confidence level.

  13. Laboratory evaluation of alcohol safety interlock systems. Volume 2 : instrument screening experiments

    DOT National Transportation Integrated Search

    1974-01-01

    The report contains the results of an experimental and analytical evaluation of instruments and techniques designed to prevent an intoxicated driver from operating his automobile. The prototype 'Alcohol Safety Interlock Systems' tested were developed...

  14. How to heat up from the cold: examining the preconditions for (unconscious) mood effects.

    PubMed

    Ruys, Kirsten I; Stapel, Diederik A

    2008-05-01

    What are the necessary preconditions to make people feel good or bad? In this research, the authors aimed to uncover the bare essentials of mood induction. Several induction techniques exist, and most of these techniques demand a relatively high amount of cognitive capacity. Moreover, to be effective, most techniques require conscious awareness. The authors proposed that the common and defining element in all effective mood induction techniques is the dominating salience of evaluative tone over descriptive meaning. This evaluative-tone hypothesis was tested in two paradigms in which the evaluative meaning of the "primed" concept was more salient than its descriptive meaning (i.e., when subliminal stimulus exposure was so short that mainly the evaluative meaning was activated [see D. A. Stapel, W. Koomen, & K. I. Ruys, 2002] and when the primed concepts were sufficiently extreme such that evaluative meaning always dominated descriptive meaning). Explicit and implicit mood measures showed that the activation of a dominating evaluative tone affected people's mood states. Implications of these findings for theories on unconscious mood induction are discussed. (c) 2008 APA, all rights reserved

  15. Assessment of non-destructive testing technologies for quality control/quality assurance of asphalt mixtures : [tech transfer summary].

    DOT National Transportation Integrated Search

    2015-02-01

    Evaluation of the actual performance (quality) of pavements requires : in situ nondestructive testing (NDT) techniques that can accurately : measure the most critical, objective, and sensitive properties of : pavement systems.

  16. A Test of Genetic Algorithms in Relevance Feedback.

    ERIC Educational Resources Information Center

    Lopez-Pujalte, Cristina; Guerrero Bote, Vicente P.; Moya Anegon, Felix de

    2002-01-01

    Discussion of information retrieval, query optimization techniques, and relevance feedback focuses on genetic algorithms, which are derived from artificial intelligence techniques. Describes an evaluation of different genetic algorithms using a residual collection method and compares results with the Ide dec-hi method (Salton and Buckley, 1990…

  17. Digital education and dynamic assessment of tongue diagnosis based on Mashup technique.

    PubMed

    Tsai, Chin-Chuan; Lo, Yen-Cheng; Chiang, John Y; Sainbuyan, Natsagdorj

    2017-01-24

    To assess the digital education and dynamic assessment of tongue diagnosis based on Mashup technique (DEDATD) according to specifific user's answering pattern, and provide pertinent information tailored to user's specifific needs supplemented by the teaching materials constantly updated through the Mashup technique. Fifty-four undergraduate students were tested with DEDATD developed. The effificacy of the DEDATD was evaluated based on the pre- and post-test performance, with interleaving training sessions targeting on the weakness of the student under test. The t-test demonstrated that signifificant difference was reached in scores gained during pre- and post-test sessions, and positive correlation between scores gained and length of time spent on learning, while no signifificant differences between the gender and post-test score, and the years of students in school and the progress in score gained. DEDATD, coupled with Mashup technique, could provide updated materials fifiltered through diverse sources located across the network. The dynamic assessment could tailor each individual learner's needs to offer custom-made learning materials. DEDATD poses as a great improvement over the traditional teaching methods.

  18. The Development and Evaluation of an Achievement Test for Measuring the Efficacy of Task-Based Writing Activities to Enhance Iranian EFL Learners' Reading Comprehension

    ERIC Educational Resources Information Center

    Nejad, Ferdows Mohsen; Khosravian, Fereshteh

    2014-01-01

    The present study examined the reliability of an achievement test to measure the efficacy of task-based writing activities to improve Iranian EFL learners' reading comprehension at the intermediate level in a private language institute in Ilam, Iran, namely Alefba language institute. To achieve the goal, the techniques for evaluating reliability…

  19. Comparative evaluation of power factor impovement techniques for squirrel cage induction motors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spee, R.; Wallace, A.K.

    1992-04-01

    This paper describes the results obtained from a series of tests of relatively simple methods of improving the power factor of squirrel-cage induction motors. The methods, which are evaluated under controlled laboratory conditions for a 10-hp, high-efficiency motor, include terminal voltage reduction; terminal static capacitors; and a floating'' winding with static capacitors. The test results are compared with equivalent circuit model predictions that are then used to identify optimum conditions for each of the power factor improvement techniques compared with the basic induction motor. Finally, the relative economic value, and the implications of component failures, of the three methods aremore » discussed.« less

  20. Needle-less local anesthesia: clinical evaluation of the effectiveness of the jet anesthesia Injex in local anesthesia in dentistry.

    PubMed

    Dabarakis, Nikolaos N; Alexander, Veis; Tsirlis, Anastasios T; Parissis, Nikolaos A; Nikolaos, Maroufidis

    2007-01-01

    To clinically evaluate the jet injection Injex (Rösch AG Medizintechnik) using 2 different anesthetic solutions, and to compare the jet injection and the standard needle injection techniques. Of the 32 patients in the study, 10 received mepivacaine 3% anesthetic solution by means of the jet injection technique, while the remaining 22 patients received lidocaine 2% with epinephrine 1:80,000 by the same method. The 14 patients in whom pulp anesthesia was achieved were selected for an additional evaluation of the pulp reaction using standard needle injection anesthesia. The differences between the 2 compounds with Injex were statistically evaluated by means of independent-samples t test analysis. The differences between subgroups receiving both jet injection and needle injection anesthesia were evaluated by means of paired t test analysis. The administration of mepivacaine 3% using Injex did not achieve pulp anesthesia in any of the 10 patients, although the soft tissue anesthesia was successful. The administration of lidocaine with epinephrine using Injex resulted in pulp anesthesia in only 14 patients; soft tissue anesthesia was observed in all patients of this group. There was no statistically significant difference between Injex and the needle injection technique in onset of anesthesia. However, the duration of anesthesia was significantly longer for the needle infiltration group than for the Injex injection group. The anesthetic solution should be combined with a vasoconstriction agent when the Injex technique is implemented.

  1. Agreement between gastrointestinal panel testing and standard microbiology methods for detecting pathogens in suspected infectious gastroenteritis: Test evaluation and meta-analysis in the absence of a reference standard.

    PubMed

    Freeman, Karoline; Tsertsvadze, Alexander; Taylor-Phillips, Sian; McCarthy, Noel; Mistry, Hema; Manuel, Rohini; Mason, James

    2017-01-01

    Multiplex gastrointestinal pathogen panel (GPP) tests simultaneously identify bacterial, viral and parasitic pathogens from the stool samples of patients with suspected infectious gastroenteritis presenting in hospital or the community. We undertook a systematic review to compare the accuracy of GPP tests with standard microbiology techniques. Searches in Medline, Embase, Web of Science and the Cochrane library were undertaken from inception to January 2016. Eligible studies compared GPP tests with standard microbiology techniques in patients with suspected gastroenteritis. Quality assessment of included studies used tailored QUADAS-2. In the absence of a reference standard we analysed test performance taking GPP tests and standard microbiology techniques in turn as the benchmark test, using random effects meta-analysis of proportions. No study provided an adequate reference standard with which to compare the test accuracy of GPP and conventional tests. Ten studies informed a meta-analysis of positive and negative agreement. Positive agreement across all pathogens was 0.93 (95% CI 0.90 to 0.96) when conventional methods were the benchmark and 0.68 (95% CI: 0.58 to 0.77) when GPP provided the benchmark. Negative agreement was high in both instances due to the high proportion of negative cases. GPP testing produced a greater number of pathogen-positive findings than conventional testing. It is unclear whether these additional 'positives' are clinically important. GPP testing has the potential to simplify testing and accelerate reporting when compared to conventional microbiology methods. However the impact of GPP testing upon the management, treatment and outcome of patients is poorly understood and further studies are needed to evaluate the health economic impact of GPP testing compared with standard methods. The review protocol is registered with PROSPERO as CRD42016033320.

  2. Micro-CT evaluation of microleakage under orthodontic ceramic brackets bonded with different bonding techniques and adhesives.

    PubMed

    Öztürk, Fırat; Ersöz, Mustafa; Öztürk, Seyit Ahmet; Hatunoğlu, Erdem; Malkoç, Sıddık

    2016-04-01

    The aim of this study was to evaluate microleakage under orthodontic ceramic brackets bonded with direct and different indirect bonding techniques and adhesives using micro-computed tomography. A total of 30 human maxillary premolars were randomly separated into five groups with six teeth in each group. In group I, teeth were bonded directly with Transbond XT (3M Unitek). In group II, group III, group IV, and group V, teeth were bonded through an indirect technique with Custom I.Q. (Reliance Orthodontic Products), Sondhi Rapid-Set (3M Unitek), RMbond (RMO), and Transbond IDB (3M Unitek), respectively, following the manufacturer's instructions. Micro-CT system model 1172 of Skyscan (Kontich, Belgium) was used to scan all samples. NRecon (Skyscan) version 1.6, CT-Analyser V.1.11 (Skyscan), and TView (SkyScan, Bvba) software programs were used for microleakage evaluation. Microleakage values between the test groups were assessed using the Kruskal-Wallis test, while the Wilcoxon signed rank test was used for within-group comparisons. The level of significance was set at P < 0.05. According to the Kruskal-Wallis analysis of variance test, there were no significant differences among the tested groups, with regard to volume and percentage (microleakage/region of interest × 100) of microleakage values (P < 0.05). The Wilcoxon signed rank test showed that coronal microleakage volume and percentage values significantly differed for RMbond and Transbond IDB groups. In the study, only ceramic brackets were used and microleakage into mini gaps did not show up on the micro-CT image because 50% silver nitrate solution could not penetrate into mini gaps which are smaller than silver nitrate particles. Use of direct and indirect bonding techniques with different adhesives did not significantly affect the amount of microleakage. © The Author 2015. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  3. Alternative Techniques for Testing A Highway Information Systems

    NASA Technical Reports Server (NTRS)

    Mast, Truman; Mast, Truman

    1974-01-01

    The highway transport system as contrasted with other modes of transportation is quite unique in that the users of the system are responsible for the guidance and control functions of the vehicle. Research has shown that improved forms of motorist information, such as highway signs and markings, can enhance the predictability and reliability of the driving task. Test and evaluation of promising new concepts in motorist information must preceed widespread endorsement and implementation on our highway system. This paper reviews the merits and limitations of presently available human factor research techniques--laboratory, instrumented vehicle and traffic performance studies on operational facilities--for evaluating the efficacy of motorist information concepts. Specific examples are given to demonstrate the utility and the interrelationships of the alternative research techniques and there is a discussion of the most pressing immediate and future needs for improved highway signing and road marking research methodology.

  4. Development of low cost custom hybrid microcircuit technology

    NASA Technical Reports Server (NTRS)

    Perkins, K. L.; Licari, J. J.

    1981-01-01

    Selected potentially low cost, alternate packaging and interconnection techniques were developed and implemented in the manufacture of specific NASA/MSFC hardware, and the actual cost savings achieved by their use. The hardware chosen as the test bed for this evaluation ws the hybrids and modules manufactured by Rockwell International fo the MSFC Flight Accelerometer Safety Cut-Off System (FASCOS). Three potentially low cost packaging and interconnection alternates were selected for evaluation. This study was performed in three phases: hardware fabrication and testing, cost comparison, and reliability evaluation.

  5. Evaluation of production tests in oil wells stimulated by massive acid fracturing offshore Qatar

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McDonald, S.W.

    This paper presents the evaluation of pressure-buildup data from production tests in wells that have been stimulated by massive acid fracturing. Fracture type curves are used in combination with conventional semilog analysis techniques. Fracture characteristics are calculated from a match of the early-time pressure data with the type curves, and reservoir characteristics are calculated from a conventional semilog plot of late-time data. Unexpectedly high formation permeabilities are evaluated, and fracture half-lengths are much shorter than design values.

  6. Comparative Evaluation of Marginal and Internal Gap of Co-Cr Copings Fabricated from Conventional Wax Pattern, 3D Printed Resin Pattern and DMLS Tech: An In Vitro Study.

    PubMed

    Bhaskaran, Eswaran; Azhagarasan, N S; Miglani, Saket; Ilango, T; Krishna, G Phani; Gajapathi, B

    2013-09-01

    Accuracy of the fit of the restoration has always remained as one of the primary factors in determining success of the restoration. A well fitting restoration needs to be accurate both along its margins and internal surface. This study was conducted to comparatively evaluate the marginal gap and internal gap of cobalt-chromium (Co-Cr) copings fabricated by conventional casting procedures and with direct metal laser sintering (DMLS) technique. Among the total of 30 test samples 10 cast copings were made from inlay casting wax and 10 from 3D printed resin pattern. 10 copings were obtained from DMLS technique. All the 30 test samples were then cemented sequentially on stainless steel model using pressure indicating paste and evaluated for vertical marginal gap in 8 predetermined reference areas. All copings were then removed and partially sectioned and cemented sequentially on same master model for evaluation of internal gap at 4 predetermined reference areas. Both marginal gap and internal gap were measured in microns using video measuring system (VMS2010F). The results obtained for both marginal and internal gap were statistically analyzed and the values fall within the clinically acceptable range. The DMLS technique had an edge over the other two techniques used, as it exhibited minimal gap in the marginal region which is an area of chief concern.

  7. Quiet Clean Short-haul Experimental Engine (QCSEE) clean combustor test report

    NASA Technical Reports Server (NTRS)

    1975-01-01

    A component pressure test was conducted on a F101 PFRT combustor to evaluate the emissions levels of this combustor design at selected under the wing and over the wing operating conditions for the quiet clean short haul experimental engine (QCSEE). Emissions reduction techniques were evaluated which included compressor discharge bleed and sector burning in the combustor. The results of this test were utilized to compare the expected QCSEE emissions levels with the emission goals of the QCSEE engine program.

  8. Energy and Technology Review

    NASA Astrophysics Data System (ADS)

    Poggio, Andrew J.

    1988-10-01

    This issue of Energy and Technology Review contains: Neutron Penumbral Imaging of Laser-Fusion Targets--using our new penumbral-imaging diagnostic, we have obtained the first images that can be used to measure directly the deuterium-tritium burn region in laser-driven fusion targets; Computed Tomography for Nondestructive Evaluation--various computed tomography systems and computational techniques are used in nondestructive evaluation; Three-Dimensional Image Analysis for Studying Nuclear Chromatin Structure--we have developed an optic-electronic system for acquiring cross-sectional views of cell nuclei, and computer codes to analyze these images and reconstruct the three-dimensional structures they represent; Imaging in the Nuclear Test Program--advanced techniques produce images of unprecedented detail and resolution from Nevada Test Site data; and Computational X-Ray Holography--visible-light experiments and numerically simulated holograms test our ideas about an X-ray microscope for biological research.

  9. Air-launched GPR evaluation for rapid assessment of MoDOT bridge decks.

    DOT National Transportation Integrated Search

    2014-08-01

    The overarching goal of this study is to demonstrate that advanced nondestructive testing/evaluation (NDT/NDE) techniques can be rapidly, effectively, and economically implemented as part of routine MoDOT bridge deck surveys to determine the general ...

  10. Audiological Evaluation for Exaggerated Hearing Level.

    ERIC Educational Resources Information Center

    Engelberg, Marvin W.

    Described are clinical techniques and procedures useful in evaluations for exaggerated hearing levels. Discussed are considerations of the audiologist, his equipment, and erroneous findings; patient cooperation, anticipated hearing handicaps, detection of exaggeration, and order of test presentation; voluntary aid conduction audiometry,…

  11. Laboratory evaluation of alcohol safety interlock systems. Volume 3 : instrument performance at high BAL

    DOT National Transportation Integrated Search

    1974-01-01

    This report contains the results of an experimental and analytical evaluation of instruments and techniques designed to prevent an intoxicated driver from operating his automobile. The prototype 'Alcohol Safety Interlock Systems' tested were develope...

  12. Synchronous Stroboscopic Electronic Speckle Pattern Interferometry

    NASA Astrophysics Data System (ADS)

    Soares, Oliverio D. D.

    1986-10-01

    Electronic Speckle Pattern Interferometry (E.S.P.I) oftenly called Electronic Holography is a practical powerful technique in non-destructive testing. Practical capabilities of the technique have been improved by fringe betterment and the control of analysis in the time domain, in particular, the scanning of the vibration cycle, with introduction of: synchronized amplitude and phase modulated pulse illumination, microcomputer control, fibre optics design, and moire evaluation techniques.

  13. Evaluation of seismic testing for quality assurance of lime-stabilized soil.

    DOT National Transportation Integrated Search

    2013-08-01

    This study sought to determine the technical feasibility of using seismic techniques to measure the : laboratory and field seismic modulus of lime-stabilized soils (LSS), and to compare/correlate test results : from bench-top (free-free resonance) se...

  14. Final evaluation report for the CAPITAL-ITS operational test and demonstration program

    DOT National Transportation Integrated Search

    1997-05-01

    The CAPITAL project was undertaken to assess the viability of using cellular-based traffic probes as a wide area vehicular traffic surveillance technique. From the test, cellular technology demonstrated the technical potential to provide vehicle spee...

  15. Preparation and testing of drilled shafts with self-consolidating concrete.

    DOT National Transportation Integrated Search

    2012-06-01

    In this study, self-consolidating concrete (SCC) was evaluated in drilled shafts and the : integrity of drilled shafts was determined using cross-hole sonic logging (CSL), a low-strain : nondestructive integrity testing technique. SCC has very high f...

  16. Real-time application of advanced three-dimensional graphic techniques for research aircraft simulation

    NASA Technical Reports Server (NTRS)

    Davis, Steven B.

    1990-01-01

    Visual aids are valuable assets to engineers for design, demonstration, and evaluation. Discussed here are a variety of advanced three-dimensional graphic techniques used to enhance the displays of test aircraft dynamics. The new software's capabilities are examined and possible future uses are considered.

  17. Using Reflection Documents to Assess Student Learning

    ERIC Educational Resources Information Center

    Powell, Larkin A.

    2009-01-01

    Traditional assessment methods such as tests and essays may not be adequate to evaluate students' ability to solve problems and think critically. I developed a qualitative assessment technique for a junior-level Wildlife Management Techniques course that incorporated written responses in a pre- and post-course reflection exercise. I provided the…

  18. Soft errors in commercial off-the-shelf static random access memories

    NASA Astrophysics Data System (ADS)

    Dilillo, L.; Tsiligiannis, G.; Gupta, V.; Bosser, A.; Saigne, F.; Wrobel, F.

    2017-01-01

    This article reviews state-of-the-art techniques for the evaluation of the effect of radiation on static random access memory (SRAM). We detailed irradiation test techniques and results from irradiation experiments with several types of particles. Two commercial SRAMs, in 90 and 65 nm technology nodes, were considered as case studies. Besides the basic static and dynamic test modes, advanced stimuli for the irradiation tests were introduced, as well as statistical post-processing techniques allowing for deeper analysis of the correlations between bit-flip cross-sections and design/architectural characteristics of the memory device. Further insight is provided on the response of irradiated stacked layer devices and on the use of characterized SRAM devices as particle detectors.

  19. Nondestructive examination of decarburised layer of steels using eddy current and magnetic Barkhausen noise testing techniques

    NASA Astrophysics Data System (ADS)

    Falahat, S.; Ghanei, S.; Kashefi, M.

    2018-04-01

    Eddy current and Barkhausen noise nondestructive testing techniques were considered to evaluate the magnetic properties of the decarburised steels as a function of microstructure. To make changes in decarburising depth, carbon steel samples were austenitised at 890 °C for 120-270 min. Considering different decarburised depths, height, position and width of the noise profiles were extracted in order to analyse the magnetic Barkhausen noise measurements. Next, the eddy current test was performed to detect the changes in the microstructure through decarburising of the steel taking into account the impedance variations. According to the results, both techniques allow us to detect changes in the magnetic properties of the decarburised steels and link them with their microstructural changes, nondestructively.

  20. Evaluation of new indigenous "point-of-care" ABO and Rh grouping device.

    PubMed

    Tiwari, Aseem Kumar; Setya, Divya; Aggarwal, Geet; Arora, Dinesh; Dara, Ravi C; Ratan, Ankita; Bhardwaj, Gunjan; Acharya, Devi Prasad

    2018-01-01

    Erycard 2.0 is a "point-of-care" device that is primarily being used for patient blood grouping before transfusion. Erycard 2.0 was compared with conventional slide technology for accuracy and time taken for ABO and Rh forward grouping result with column agglutination technology (CAT) being the gold standard. Erycard 2.0 as a device was also evaluated for its stability under different storage conditions and stability of result till 48 h. In addition, grouping of hemolyzed samples was also tested with Erycard 2.0. Ease of use of Erycard 2.0 was evaluated with a survey among paramedical staff. Erycard 2.0 demonstrated 100% concordance with CAT as compared with slide technique (98.9%). Mean time taken per test by Erycard 2.0 and slide technique was 5.13 min and 1.7 min, respectively. After pretesting storage under different temperature and humidity conditions, Erycard 2.0 did not show any deviation from the result. The result did not change even after 48 h of testing and storage under room temperature. 100% concordance was recorded between pre- and post-hemolyzed blood grouping. Ease of use survey revealed that Erycard 2.0 was more acceptable to paramedical staff for its simplicity, objectivity, and performance than conventional slide technique. Erycard 2.0 can be used as "point-of-care" device for blood donor screening for ABO and Rh blood group and can possibly replace conventional slide technique.

  1. Evaluation of new indigenous “point-of-care” ABO and Rh grouping device

    PubMed Central

    Tiwari, Aseem Kumar; Setya, Divya; Aggarwal, Geet; Arora, Dinesh; Dara, Ravi C.; Ratan, Ankita; Bhardwaj, Gunjan; Acharya, Devi Prasad

    2018-01-01

    BACKGROUND: Erycard 2.0 is a “point-of-care” device that is primarily being used for patient blood grouping before transfusion. MATERIALS AND METHODS: Erycard 2.0 was compared with conventional slide technology for accuracy and time taken for ABO and Rh forward grouping result with column agglutination technology (CAT) being the gold standard. Erycard 2.0 as a device was also evaluated for its stability under different storage conditions and stability of result till 48 h. In addition, grouping of hemolyzed samples was also tested with Erycard 2.0. Ease of use of Erycard 2.0 was evaluated with a survey among paramedical staff. RESULTS: Erycard 2.0 demonstrated 100% concordance with CAT as compared with slide technique (98.9%). Mean time taken per test by Erycard 2.0 and slide technique was 5.13 min and 1.7 min, respectively. After pretesting storage under different temperature and humidity conditions, Erycard 2.0 did not show any deviation from the result. The result did not change even after 48 h of testing and storage under room temperature. 100% concordance was recorded between pre- and post-hemolyzed blood grouping. Ease of use survey revealed that Erycard 2.0 was more acceptable to paramedical staff for its simplicity, objectivity, and performance than conventional slide technique. CONCLUSION: Erycard 2.0 can be used as “point-of-care” device for blood donor screening for ABO and Rh blood group and can possibly replace conventional slide technique. PMID:29403211

  2. AGARD Flight Test Techniques Series. Volume 12. The Principles of Flight Test Assessment of Flight-Safety-Critical Systems in Helicopters (Les Principes de l’Evaluation, dans le Cadre des Essais en Vol, des Systemes Indispensables a la Securite de Vol des Helicopteres)

    DTIC Science & Technology

    1994-08-01

    AGARD-AG-300 Vol. 12 04 ADVISORY GROUP FOR AEROSPACE RESEARCH & DEVELOPMENT 7 RUE ANCELLE, 92200 NEUILLY-SUR-SEINE, FRANCE AUG 0195 AGARDograph 300...AGARD Flight Test Techniques Series Volume 12 on The Principles of Flight Test Assessment of Flight-Safety-Critical Systems in Helicopters (Les...and Availability on Back Cover AGARD-AG-300 Vol. 12 ADVISORY GROUP FOR AEROSPACE RESEARCH & DEVELOPMENT 7 RUE ANCELLE, 92200 NEUILLY-SUR-SEINE, FRANCE

  3. Evaluation of the ecological relevance of mysid toxicity tests using population modeling techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuhn-Hines, A.; Munns, W.R. Jr.; Lussier, S.

    1995-12-31

    A number of acute and chronic bioassay statistics are used to evaluate the toxicity and risks of chemical stressors to the mysid shrimp, Mysidopsis bahia. These include LC{sub 50}S from acute tests, NOECs from 7-day and life-cycle tests, and the US EPA Water Quality Criteria Criterion Continuous Concentrations (CCC). Because these statistics are generated from endpoints which focus upon the responses of individual organisms, their relationships to significant effects at higher levels of ecological organization are unknown. This study was conducted to evaluate the quantitative relationships between toxicity test statistics and a concentration-based statistic derived from exposure-response models describing populationmore » growth rate ({lambda}) to stressor concentration. This statistic, C{sup {sm_bullet}} (concentration where {lambda} = I, zero population growth) describes the concentration above which mysid populations are projected to decline in abundance as determined using population modeling techniques. An analysis of M. bahia responses to 9 metals and 9 organic contaminants indicated the NOEC from life-cycle tests to be the best predictor of C{sup {sm_bullet}}, although the acute LC{sub 50} predicted population-level response surprisingly well. These analyses provide useful information regarding uncertainties of extrapolation among test statistics in assessments of ecological risk.« less

  4. MALDI-TOF for the rapid detection of carbapenemase-producing Enterobacteriaceae: comparison of the commercialized MBT STAR®-Carba IVD Kit with two in-house MALDI-TOF techniques and the RAPIDEC® CARBA NP.

    PubMed

    Dortet, Laurent; Tandé, Didier; de Briel, Dominique; Bernabeu, Sandrine; Lasserre, Camille; Gregorowicz, Guillaume; Jousset, Agnès B; Naas, Thierry

    2018-06-11

    There is an urgent need for accurate and fast diagnostic tests to identify carbapenemase-producing bacteria. Here, we have evaluated three MALDI-TOF-based techniques to detect carbapenemase-producing Enterobacteriaceae (CPE) from cultured colonies. The performance of three MALDI-TOF-based techniques, including the commercialized MBT STAR®-Carba IVD Kit (Bruker Daltonics) and two in-house protocols performed on the Microflex LT Biotyper (Bruker Daltonics) and the VITEK® MS Plus (bioMérieux), were compared with those of the RAPIDEC® CARBA NP (bioMérieux). A collection of 175 isolates including 120 carbapenemase producers and 55 non-carbapenemase producers was tested. Samples were tested blind in the three participating centres. The repeatability of the MBT STAR®-Carba IVD Kit was also evaluated. The three MALDI-TOF techniques possess sensitivities ranging from 95% to 100% and specificities from 98.2% to 100% compared with 99.2% and 100%, respectively, for the RAPIDEC® CARBA NP. The MBT STAR®-Carba IVD Kit gave highly reproducible results and is the only technique able to provide a concomitant identification of the bacterial isolate. The three MALDI-TOF techniques possess a fast turnaround time (less than 1.5 h). Overall, MALDI-TOF is a reliable technique for the rapid detection of CPE from cultured colonies. MBT STAR®-Carba IVD Kit, the only commercially available assay, could easily be implemented in a clinical microbiology laboratory if it is already equipped with a Microflex LT Biotyper mass spectrometer.

  5. Comparison of machine learning techniques to predict all-cause mortality using fitness data: the Henry ford exercIse testing (FIT) project.

    PubMed

    Sakr, Sherif; Elshawi, Radwa; Ahmed, Amjad M; Qureshi, Waqas T; Brawner, Clinton A; Keteyian, Steven J; Blaha, Michael J; Al-Mallah, Mouaz H

    2017-12-19

    Prior studies have demonstrated that cardiorespiratory fitness (CRF) is a strong marker of cardiovascular health. Machine learning (ML) can enhance the prediction of outcomes through classification techniques that classify the data into predetermined categories. The aim of this study is to present an evaluation and comparison of how machine learning techniques can be applied on medical records of cardiorespiratory fitness and how the various techniques differ in terms of capabilities of predicting medical outcomes (e.g. mortality). We use data of 34,212 patients free of known coronary artery disease or heart failure who underwent clinician-referred exercise treadmill stress testing at Henry Ford Health Systems Between 1991 and 2009 and had a complete 10-year follow-up. Seven machine learning classification techniques were evaluated: Decision Tree (DT), Support Vector Machine (SVM), Artificial Neural Networks (ANN), Naïve Bayesian Classifier (BC), Bayesian Network (BN), K-Nearest Neighbor (KNN) and Random Forest (RF). In order to handle the imbalanced dataset used, the Synthetic Minority Over-Sampling Technique (SMOTE) is used. Two set of experiments have been conducted with and without the SMOTE sampling technique. On average over different evaluation metrics, SVM Classifier has shown the lowest performance while other models like BN, BC and DT performed better. The RF classifier has shown the best performance (AUC = 0.97) among all models trained using the SMOTE sampling. The results show that various ML techniques can significantly vary in terms of its performance for the different evaluation metrics. It is also not necessarily that the more complex the ML model, the more prediction accuracy can be achieved. The prediction performance of all models trained with SMOTE is much better than the performance of models trained without SMOTE. The study shows the potential of machine learning methods for predicting all-cause mortality using cardiorespiratory fitness data.

  6. Quality control procedures for dynamic treatment delivery techniques involving couch motion.

    PubMed

    Yu, Victoria Y; Fahimian, Benjamin P; Xing, Lei; Hristov, Dimitre H

    2014-08-01

    In this study, the authors introduce and demonstrate quality control procedures for evaluating the geometric and dosimetric fidelity of dynamic treatment delivery techniques involving treatment couch motion synchronous with gantry and multileaf collimator (MLC). Tests were designed to evaluate positional accuracy, velocity constancy and accuracy for dynamic couch motion under a realistic weight load. A test evaluating the geometric accuracy of the system in delivering treatments over complex dynamic trajectories was also devised. Custom XML scripts that control the Varian TrueBeam™ STx (Serial #3) axes in Developer Mode were written to implement the delivery sequences for the tests. Delivered dose patterns were captured with radiographic film or the electronic portal imaging device. The couch translational accuracy in dynamic treatment mode was 0.01 cm. Rotational accuracy was within 0.3°, with 0.04 cm displacement of the rotational axis. Dose intensity profiles capturing the velocity constancy and accuracy for translations and rotation exhibited standard deviation and maximum deviations below 3%. For complex delivery involving MLC and couch motions, the overall translational accuracy for reproducing programmed patterns was within 0.06 cm. The authors conclude that in Developer Mode, TrueBeam™ is capable of delivering dynamic treatment delivery techniques involving couch motion with good geometric and dosimetric fidelity.

  7. Evaluation of Two Protocols to Measure the Accuracy of Fixed Dental Prostheses: An In Vitro Study.

    PubMed

    Schönberger, Joana; Erdelt, Kurt-Jürgen; Bäumer, Daniel; Beuer, Florian

    2017-02-02

    The aim of this in vitro study was to compare two measurement protocols of the internal and marginal fit of three-unit zirconia fixed dental prostheses (FDPs). Forty-four FDPs were fabricated for standardized dies by two laboratory CAD/CAM systems: Cercon (n = 22) and Ceramill (n = 22). The fitting was tested using a replica technique (RT = technique 1) with a light-body silicone stabilized with heavy-body material. After producing the replicas, cross-sections were made in the buccolingual and mesiodistal directions. FDPs were cemented on definitive dies, embedded, and sectioned (CST = technique 2). The marginal and internal fits were measured under an optical microscope at 50x magnification with a special software program. Data evaluation was performed according to prior studies at a level of significance of 5%. The mean internal gap width was 51 ± 36 μm for the RT and 52 ± 35 μm for the cross-section technique (CST) (p = 0.74). The mean marginal gap width was 27 ± 18 μm for RT and 30 ± 19 μm for CST (p = 0.19). Statistical tests showed no significant differences (p > 0.05). Both techniques can be used for fit evaluation; however, the noninvasive RT is suitable for clinical use. © 2017 by the American College of Prosthodontists.

  8. Evaluating the Sensitivity of a Media-Fill Challenge Test Under Various Situations as a Reliable Method for Recommended Aseptic Technique Competency Assessment

    PubMed Central

    Moody, Colleen A.; Eckel, Stephen F.; Amerine, Lindsey B.

    2015-01-01

    Background: Microbial contamination of compounded medications is a serious concern within hospital pharmacies as it can lead to severe patient injury. The United States Pharmacopeia <797> mandates that pharmacy personnel responsible for preparing compounded sterile preparations must annually demonstrate competency in aseptic technique by performing a media-fill challenge test. Objective: The purpose of this study is to evaluate the sensitivity of a commonly used media-fill test through proper and improper compounding techniques. Methods: Two aseptically trained pharmacy technicians performed media-fill challenge testing by carrying out 5 separate manipulations 5 times each for a total of 25 trials. Sterile vials, syringes, and intravenous bags were prepared. The first manipulation followed best-practice aseptic technique and sterile compounding procedures. Each of the following 4 manipulations removed one aspect of best-practice aseptic technique. The prepared products were incubated at 20°C to 25°C. A positive result for microbial contamination is indicated by visible turbidity within the vials, syringes, and intravenous bags at the following check points: 24 hours, 72 hours, 7 days, 14 days, 21 days, and >30 days. Results: Twenty-five trials, each containing 10 distinct admixtures, resulted in a total of 250 compounded preparations. No single preparation showed signs of turbidity, sedimentation, or visible microbial growth at any of the 6 checkpoints yielding a 0% contamination rate. However, the positive controls inoculated with bacteria did have positive microbial growth results. Conclusion: A more sensitive test needs to be developed to provide assurances that all poor aseptic practices are detected in compounding personnel.

  9. Evaluation of metal-ceramic bond characteristics of three dental Co-Cr alloys prepared with different fabrication techniques.

    PubMed

    Wang, Hongmei; Feng, Qing; Li, Ning; Xu, Sheng

    2016-12-01

    Limited information is available regarding the metal-ceramic bond strength of dental Co-Cr alloys fabricated by casting (CAST), computer numerical control (CNC) milling, and selective laser melting (SLM). The purpose of this in vitro study was to evaluate the metal-ceramic bond characteristics of 3 dental Co-Cr alloys fabricated by casting, computer numerical control milling, and selective laser melting techniques using the 3-point bend test (International Organization for Standardization [ISO] standard 9693). Forty-five specimens (25×3×0.5 mm) made of dental Co-Cr alloys were prepared by CAST, CNC milling, and SLM techniques. The morphology of the oxidation surface of metal specimens was evaluated by scanning electron microscopy (SEM). After porcelain application, the interfacial characterization was evaluated by SEM equipped with energy-dispersive spectrometry (EDS) analysis, and the metal-ceramic bond strength was assessed with the 3-point bend test. Failure type and elemental composition on the debonding interface were assessed by SEM/EDS. The bond strength was statistically analyzed by 1-way ANOVA and Tukey honest significant difference test (α=.05). The oxidation surfaces of the CAST, CNC, and SLM groups were different. They were porous in the CAST group but compact and irregular in the CNC and SLM groups. The metal-ceramic interfaces of the SLM and CNC groups showed excellent combination compared with those of the CAST group. The bond strength was 37.7 ±6.5 MPa for CAST, 43.3 ±9.2 MPa for CNC, and 46.8 ±5.1 MPa for the SLM group. Statistically significant differences were found among the 3 groups tested (P=.028). The debonding surfaces of all specimens exhibited cohesive failure mode. The oxidation surface morphologies and thicknesses of dental Co-Cr alloys are dependent on the different fabrication techniques used. The bond strength of all 3 groups exceed the minimum acceptable value of 25 MPa recommended by ISO 9693; hence, dental Co-Cr alloy fabricated with the SLM techniques could be a promising alternative for metal ceramic restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. Hepatic lesions: improved image quality and detection with the periodically rotated overlapping parallel lines with enhanced reconstruction technique--evaluation of SPIO-enhanced T2-weighted MR images.

    PubMed

    Hirokawa, Yuusuke; Isoda, Hiroyoshi; Maetani, Yoji S; Arizono, Shigeki; Shimada, Kotaro; Okada, Tomohisa; Shibata, Toshiya; Togashi, Kaori

    2009-05-01

    To evaluate the effectiveness of the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique for superparamagnetic iron oxide (SPIO)-enhanced T2-weighted magnetic resonance (MR) imaging with respiratory compensation with the prospective acquisition correction (PACE) technique in the detection of hepatic lesions. The institutional human research committee approved this prospective study, and all patients provided written informed consent. Eighty-one patients (mean age, 58 years) underwent hepatic 1.5-T MR imaging. Fat-saturated T2-weighted turbo spin-echo images were acquired with the PACE technique and with and without the PROPELLER method after administration of SPIO. Images were qualitatively evaluated for image artifacts, depiction of liver edge and intrahepatic vessels, overall image quality, and presence of lesions. Three radiologists independently assessed these characteristics with a five-point confidence scale. Diagnostic performance was assessed with receiver operating characteristic (ROC) curve analysis. Quantitative analysis was conducted by measuring the liver signal-to-noise ratio (SNR) and the lesion-to-liver contrast-to-noise ratio (CNR). The Wilcoxon signed rank test and two-tailed Student t test were used, and P < .05 indicated a significant difference. MR imaging with the PROPELLER and PACE techniques resulted in significantly improved image quality, higher sensitivity, and greater area under the ROC curve for hepatic lesion detection than did MR imaging with the PACE technique alone (P < .001). The mean liver SNR and the lesion-to-liver CNR were higher with the PROPELLER technique than without it (P < .001). T2-weighted MR imaging with the PROPELLER and PACE technique and SPIO enhancement is a promising method with which to improve the detection of hepatic lesions. (c) RSNA, 2009.

  11. Assessment of NDE Methods to Detect Lack of Fusion in HDPE Butt Fusion Joints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crawford, Susan L.; Doctor, Steven R.; Cinson, Anthony D.

    2011-07-31

    Studies at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington, were conducted to evaluate nondestructive examinations (NDE) coupled with mechanical testing of butt fusion joints in high-density polyethylene (HDPE) pipe for assessing lack of fusion. The work provided information to the United States Nuclear Regulatory Commission (NRC) on the effectiveness of volumetric inspection techniques of HDPE butt fusion joints in Section III, Division 1, Class 3, buried piping systems in nuclear power plants. This paper describes results from assessments using ultrasonic and microwave nondestructive techniques and mechanical testing with the high-speed tensile impact test and the side-bend test formore » determining joint integrity. A series of butt joints were fabricated in 3408, 12-inch (30.5-cm) IPS DR-11 HDPE material by varying the fusion parameters to create good joints and joints containing a range of lack-of-fusion conditions. Six of these butt joints were volumetrically examined with time-of-flight diffraction (TOFD), phased-array (PA) ultrasound, and the Evisive microwave system. The outer diameter (OD) weld beads were removed for microwave evaluation and the pipes ultrasonically re-evaluated. In two of the six pipes, both the outer and inner diameter (ID) weld beads were removed and the pipe joints re-evaluated. Some of the pipes were sectioned and the joints destructively evaluated with the high-speed tensile test and the side-bend test. The fusion parameters, nondestructive and destructive evaluation results have been correlated to validate the effectiveness of what each NDE technology detects and what each does not detect. There was no single NDE method that detected all of the lack-of-fusion flaws but a combination of NDE methods did detect most of the flaws.« less

  12. Permeability evaluation after decay removal in primary teeth with current caries-excavation techniques.

    PubMed

    Shabzendedar, Mahbobeh; Moosavi, Horieh; Talbi, Maryam; Sharifi, Marjan

    2011-11-01

    The goal of the study was to evaluate the effect of caries removal by three various methods on the permeability of class II composite resin restorations in primary molar teeth. Forty-five recently extracted primary molars were randomly assigned to three groups for three different methods of caries removal; group 1-mechanical, group 2-caries detector dye, and group 3-Carisolv (n = 15). After that, class II cavities in all groups were restored with the adhesive (Opti Bond Solo Plus) that was applied according to the manufacturer's instruction and a posterior composite (Herculite XRV), which was used incrementally. After 24 hours the samples were thermocycled in water for 500 cycles between 5 and 55°C with a dwell time of 30 sec. Permeability was assessed by the fluid filtration method. The data were analyzed using the ANOVA test while study groups were compared with Tukey test for statistically significant differences at a 5% significance level. The evaluation of tested groups indicated that the highest (0.80) and least (0.37) mean of permeability was observed in group 2 and 3 respectively. Significant difference was revealed among the tested groups (p = 0.045). The comparison of Carisolv and caries detector dye groups indicated a statistically significant difference (p = 0.037). There was not any significant difference between Carisolv or caries dye in the conventional group. Using the chemomechanical and staining methods for caries removal had no more detrimental effect on permeability than the conventional technique. However, caries detection dye for caries removal could be more harmful than chemomechanical method. None of the current caries-excavation techniques could eliminate permeability in class II composite resin restorations. Furthermore, staining methods do not have an adverse effect on sealing ability in comparison to the conventional technique.

  13. Evaluation of remediation techniques in soils affected by residual contamination with heavy metals and arsenic.

    PubMed

    García-Carmona, M; Romero-Freire, A; Sierra Aragón, M; Martínez Garzón, F J; Martín Peinado, F J

    2017-04-15

    Residual soil pollution from the Aznalcóllar mine spill is still a problem in some parts of the affected area, today converted in the Guadiamar Green Corridor. Dispersed spots of polluted soils, identified by the absence of vegetation, are characterized by soil acid pH and high concentrations of As, Pb, Cu and Zn. Ex situ remediation techniques were performed with unrecovered soil samples. Landfarming, Composting and Biopiles techniques were tested in order to immobilize pollutants, to improve soil properties and to promote vegetation recovery. The effectiveness of these techniques was assessed by toxicity bioassays: Lactuca sativa L. root elongation test, Vibrio fischeri bioluminescence reduction test, soil induced respiration test, and Eisenia andrei survival and metal bioaccumulation tests. Landfarming and Composting were not effective techniques, mainly due to the poor improvement of soil properties which maintained high soluble concentrations of Zn and Cu after treatments. Biopile technique, using adjacent recovered soils in the area, was the most effective action in the reduction of soil toxicity; the improvement of soil properties and the reduction in pollutants solubility were key to improve the response of the tested organisms. Therefore, the mixture of recovered soils with polluted soils in the areas affected by residual contamination is considered a more suitable technique to reduce the residual pollution and to promote the complete soil recovery in the Guadiamar Green Corridor. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. The Impact of Cooperative Learning on Critical Thinking Test Scores of Associate's Degree Graduates in Southwest Virginia

    ERIC Educational Resources Information Center

    Hodges, James Gregory

    2013-01-01

    This study examined the impact that the teaching technique known as cooperative learning had on the changes between pre- and post-test scores on all sub-categories ("induction, deduction, analysis, evaluation, inference", and "total composite") associated with the "California Critical Thinking Skills Test" (CCTST) for…

  15. TEST KIT FOR FIELD EVALUATION OF THE CHEMICAL RESISTANCE OF PROTECTIVE CLOTHING

    EPA Science Inventory

    Personnel involved in emergency response and hazardous waste site activities often have the need to reach on-scene decisions regarding the effectiveness and limitations of chemical protective clothing. Three gravimetric techniques were evaluated as means for providing essential i...

  16. Optimal Settings for the Noncontact Holmium:YAG Stone Fragmentation Popcorn Technique.

    PubMed

    Emiliani, Esteban; Talso, Michele; Cho, Sung-Yong; Baghdadi, Mohammed; Mahmoud, Sadam; Pinheiro, Hugo; Traxer, Olivier

    2017-09-01

    The purpose of this study was to evaluate the popcorn technique using a wide range of holmium laser settings and fiber sizes in a systematic in vitro assessment. Evaluations were done with 4 artificial stones in a collection tube. A fixed ureteroscope was inserted through a ureteral access sheath to provide constant irrigation flow and the laser was placed 1 mm from the bottom. Combinations of 0.5 to 1.5 J, 10 to 20 and 40 Hz, and long and short pulses were tested for 2 and 4 minutes. We used 273 and 365 μm laser fibers. All tests were repeated 3 times. The stones were weighed before and after the experiments to evaluate the setting efficiency. Significant predictors of a highly efficient technique were assessed. A total of 144 tests were performed. Mean starting weight of the stones was 0.23 gm, which was consistent among the groups. After the experiment the median weight difference was 0.07 gm (range 0.01 to 0.24). When designating a 50% reduction in stone volume as the threshold indicating high efficiency, the significant predictors of an efficient popcorn technique were a long pulse (OR 2.7, 95% CI 1.05-7.15), a longer duration (OR 11.4, 95% CI 3.88-33.29), a small (273 μm) laser fiber (OR 0.23, 95% CI 0.08-0.70) and higher power (W) (OR 1.14, 95% CI 1.09-1.20). Higher energy, a longer pulse, frequencies higher than 10 Hz, a longer duration and a smaller laser fiber predict a popcorn technique that is more efficient at reducing stone volume. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. Validation and evaluation of measuring methods for the 3D documentation of external injuries in the field of forensic medicine.

    PubMed

    Buck, Ursula; Buße, Kirsten; Campana, Lorenzo; Schyma, Christian

    2018-03-01

    Three-dimensional (3D) measurement techniques are gaining importance in many areas. The latest developments brought more cost-effective, user-friendly, and faster technologies onto the market. Which 3D techniques are suitable in the field of forensic medicine and what are their advantages and disadvantages? This wide-ranging study evaluated and validated various 3D measurement techniques for the forensic requirements. High-tech methods as well as low-budget systems have been tested and compared in terms of accuracy, ease of use, expenditure of time, mobility, cost, necessary knowhow, and their limitations. Within this study, various commercial measuring systems of the different techniques were tested. Based on the first results, one measuring system was selected for each technique, which appeared to be the most suitable for the forensic application or is already established in forensic medicine. A body of a deceased, a face and an injury of a living person, and a shoe sole were recorded by 11 people with different professions and previous knowledge using the selected systems. The results were assessed and the personal experiences were evaluated using a questionnaire. In addition, precision investigations were carried out using test objects. The study shows that the hand-held scanner and photogrammetry are very suitable for the 3D documentation of forensic medical findings. Their moderate acquisition costs and easy operation could lead to more frequent application in forensic medicine in the future. For special applications, the stripe-light scanner still has its justification due to its high precision, the flexible application area, and the high reliability. The results show that, thanks to the technological advances, the 3D measurement technology will have more and more impact on the routine of the forensic medical examination.

  18. Solderability test system

    DOEpatents

    Yost, Fred; Hosking, Floyd M.; Jellison, James L.; Short, Bruce; Giversen, Terri; Reed, Jimmy R.

    1998-01-01

    A new test method to quantify capillary flow solderability on a printed wiring board surface finish. The test is based on solder flow from a pad onto narrow strips or lines. A test procedure and video image analysis technique were developed for conducting the test and evaluating the data. Feasibility tests revealed that the wetted distance was sensitive to the ratio of pad radius to line width (l/r), solder volume, and flux predry time.

  19. Closed-loop, pilot/vehicle analysis of the approach and landing task

    NASA Technical Reports Server (NTRS)

    Schmidt, D. K.; Anderson, M. R.

    1985-01-01

    Optimal-control-theoretic modeling and frequency-domain analysis is the methodology proposed to evaluate analytically the handling qualities of higher-order manually controlled dynamic systems. Fundamental to the methodology is evaluating the interplay between pilot workload and closed-loop pilot/vehicle performance and stability robustness. The model-based metric for pilot workload is the required pilot phase compensation. Pilot/vehicle performance and loop stability is then evaluated using frequency-domain techniques. When these techniques were applied to the flight-test data for thirty-two highly-augmented fighter configurations, strong correlation was obtained between the analytical and experimental results.

  20. Evaluation of a catalytic reduction technique for the measurement of total reactive odd-nitrogen NOy in the atmosphere

    NASA Technical Reports Server (NTRS)

    Fahey, D. W.; Eubank, C. S.; Hubler, C. S.; Fehsenfeld, F. C.

    1985-01-01

    The suitability of a technique for the measurement of total reactive odd-nitrogen NOy-containing species in the atmosphere has been examined. In the technique, an NOy component species, which may include NO, NO2, NO3, HNO3, peroxyacetyl nitrate, and particulate nitrate, are catalytically reduced by CO to form NO molecules on the surface of a metal converter tube, and the NO product is detected by chemiluminescence produced in reaction with O3. Among the catalysts tested in the temperature range of 25-500 C, Au was the preferred catalyst. The results of laboratory tests investigating the effects of pressure, O3, and H2O on NOy conversion, and the possible sources of interference, have shown that the technique is suitable for atmospheric analyses. The results of a test in ambient air at a remote ground-based field site are included.

  1. An assessment of the Nguyen and Pinder method for slug test analysis. [In situ estimates of ground water contamination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butler, J.J. Jr.; Hyder, Z.

    The Nguyen and Pinder method is one of four techniques commonly used for analysis of response data from slug tests. Limited field research has raised questions about the reliability of the parameter estimates obtained with this method. A theoretical evaluation of this technique reveals that errors were made in the derivation of the analytical solution upon which the technique is based. Simulation and field examples show that the errors result in parameter estimates that can differ from actual values by orders of magnitude. These findings indicate that the Nguyen and Pinder method should no longer be a tool in themore » repertoire of the field hydrogeologist. If data from a slug test performed in a partially penetrating well in a confined aquifer need to be analyzed, recent work has shown that the Hvorslev method is the best alternative among the commonly used techniques.« less

  2. A technique for extracting blood samples from mice in fire toxicity tests

    NASA Technical Reports Server (NTRS)

    Bucci, T. J.; Hilado, C. J.; Lopez, M. T.

    1976-01-01

    The extraction of adequate blood samples from moribund and dead mice has been a problem because of the small quantity of blood in each animal and the short time available between the animals' death and coagulation of the blood. These difficulties are particularly critical in fire toxicity tests because removal of the test animals while observing proper safety precautions for personnel is time-consuming. Techniques for extracting blood samples from mice were evaluated, and a technique was developed to obtain up to 0.8 ml of blood from a single mouse after death. The technique involves rapid exposure and cutting of the posterior vena cava and accumulation of blood in the peritoneal space. Blood samples of 0.5 ml or more from individual mice have been consistently obtained as much as 16 minutes after apparent death. Results of carboxyhemoglobin analyses of blood appeared reproducible and consistent with carbon monoxide concentrations in the exposure chamber.

  3. Refurbishment cost study of the thermal protection system of a space shuttle vehicle, phase 2

    NASA Technical Reports Server (NTRS)

    Haas, D. W.

    1972-01-01

    The labor costs and techniques associated with the refurbishment and maintenance of representative thermal protection system (TPS) components and their attachment concepts suitable for space shuttle application are defined, characterized, and evaluated from the results of an experimental test program. This program consisted of designing selected TPS concepts, fabricating and assembling test hardware, and performing a time and motion study of specific maintenance functions of the test hardware on a full-scale- mockup. Labor requirements and refurbishment techniques, as they relate to the maintenance functions of inspection, repair, removal, and replacement were identified.

  4. Privacy-preserving genome-wide association studies on cloud environment using fully homomorphic encryption

    PubMed Central

    2015-01-01

    Objective Developed sequencing techniques are yielding large-scale genomic data at low cost. A genome-wide association study (GWAS) targeting genetic variations that are significantly associated with a particular disease offers great potential for medical improvement. However, subjects who volunteer their genomic data expose themselves to the risk of privacy invasion; these privacy concerns prevent efficient genomic data sharing. Our goal is to presents a cryptographic solution to this problem. Methods To maintain the privacy of subjects, we propose encryption of all genotype and phenotype data. To allow the cloud to perform meaningful computation in relation to the encrypted data, we use a fully homomorphic encryption scheme. Noting that we can evaluate typical statistics for GWAS from a frequency table, our solution evaluates frequency tables with encrypted genomic and clinical data as input. We propose to use a packing technique for efficient evaluation of these frequency tables. Results Our solution supports evaluation of the D′ measure of linkage disequilibrium, the Hardy-Weinberg Equilibrium, the χ2 test, etc. In this paper, we take χ2 test and linkage disequilibrium as examples and demonstrate how we can conduct these algorithms securely and efficiently in an outsourcing setting. We demonstrate with experimentation that secure outsourcing computation of one χ2 test with 10, 000 subjects requires about 35 ms and evaluation of one linkage disequilibrium with 10, 000 subjects requires about 80 ms. Conclusions With appropriate encoding and packing technique, cryptographic solutions based on fully homomorphic encryption for secure computations of GWAS can be practical. PMID:26732892

  5. Fractured reservoir characterization through injection, falloff, and flowback tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peng, C.P.; Singh, P.K.; Halvorsen, H.

    1992-09-01

    This paper presents the development of a multiphase pressure-transient-analysis technique for naturally fractured reservoirs and the analysis of a series of field tests performed to evaluate the water injection potential and the reservoir characteristics of a naturally fractured reservoir. These included step-rate, water-injectivity, pressure-falloff, and flowback tests. Through these tests, a description of the reservoir was obtained.

  6. The monitoring of antigen levels during inactivated poliovirus vaccine production: evaluation of filtration techniques.

    PubMed

    Moynihan, M; Petersen, I

    1981-01-01

    The use of ELISA to estimate poliovirus antigen concentration has permitted an evaluation of the methodology used in vaccine production and allowed exploration of less wasteful filtration-techniques. The replacement of Seitz-EKS-1B filtration with either Seitz-Supra-EKS or Pall-filtration in the preparation of the vaccine could make a large saving in the total antigen yield, but the results in the safety test excluded their possible use in our process as it stands at the moment.

  7. Automated array assembly

    NASA Technical Reports Server (NTRS)

    Williams, B. F.

    1976-01-01

    Manufacturing techniques are evaluated using expenses based on experience and studying basic cost factors for each step to evaluate expenses from a first-principles point of view. A formal cost accounting procedure is developed which is used throughout the study for cost comparisons. The first test of this procedure is a comparison of its predicted costs for array module manufacturing with costs from a study which is based on experience factors. A manufacturing cost estimate for array modules of $10/W is based on present-day manufacturing techniques, expenses, and materials costs.

  8. Evaluation of vibrated fluidized bed techniques in coating hemosorbents.

    PubMed

    Morley, D B

    1991-06-01

    A coating technique employing a vibrated fluidized bed was used to apply an ultrathin (2 microns) cellulose nitrate coating to synthetic bead activated charcoal. In vitro characteristics of the resulting coated sorbent, including permeability to model small and middle molecules, and mechanical integrity, were evaluated to determine the suitability of the process in coating granular sorbents used in hemoperfusion. Initial tests suggest the VFB-applied CN coating is both highly uniform and tightly adherent and warrants further investigation as a hemosorbent coating.

  9. Advantages and disadvantages of technologies for HER2 testing in breast cancer specimens.

    PubMed

    Furrer, Daniela; Sanschagrin, François; Jacob, Simon; Diorio, Caroline

    2015-11-01

    Human epidermal growth factor receptor 2 (HER2) plays a central role as a prognostic and predictive marker in breast cancer specimens. Reliable HER2 evaluation is central to determine the eligibility of patients with breast cancer to targeted anti-HER2 therapies such as trastuzumab and lapatinib. Presently, several methods exist for the determination of HER2 status at different levels (protein, RNA, and DNA level). In this review, we discuss the main advantages and disadvantages of the techniques developed so far for the evaluation of HER2 status in breast cancer specimens. Each technique has its own advantages and disadvantages. It is therefore not surprising that no consensus has been reached so far on which technique is the best for the determination of HER2 status. Currently, emphasis must be put on standardization of procedures, internal and external quality control assessment, and competency evaluation of already existing methods to ensure accurate, reliable, and clinically meaningful test results. Development of new robust and accurate diagnostic assays should also be encouraged. In addition, large clinical trials are warranted to identify the technique that most reliably predicts a positive response to anti-HER2 drugs. Copyright© by the American Society for Clinical Pathology.

  10. Development of a technique for inflight jet noise simulation. I, II

    NASA Technical Reports Server (NTRS)

    Clapper, W. S.; Stringas, E. J.; Mani, R.; Banerian, G.

    1976-01-01

    Several possible noise simulation techniques were evaluated, including closed circuit wind tunnels, free jets, rocket sleds and high speed trains. The free jet technique was selected for demonstration and verification. The first paper describes the selection and development of the technique and presents results for simulation and in-flight tests of the Learjet, F106, and Bertin Aerotrain. The second presents a theoretical study relating the two sets of noise signatures. It is concluded that the free jet simulation technique provides a satisfactory assessment of in-flight noise.

  11. Mechanical system diagnostics using vibration testing techniques

    NASA Technical Reports Server (NTRS)

    Mcleod, Catherine D.; Raju, P. K.; Crocker, M. J.

    1990-01-01

    The 'Cepstrum' technique of vibration-path identification allows the recovery of the transfer function of a system with little knowledge as to its excitation force, by means of a mathematical manipulation of the system output in conjunction with subtraction of part of the output and suitable signal processing. An experimental program has been conducted to evaluate the usefulness of this technique in the cases of simple, cantilever-beam and free-free plate structures as well as in that of a complex mechanical system. On the basis of the transfer functions thus recovered, it was possible to evaluate the shifts in the resonance frequencies of a structure due to the presence of defects.

  12. Acoustic emission from composite materials. [nondestructive tests

    NASA Technical Reports Server (NTRS)

    Visconti, I. C.; Teti, R.

    1979-01-01

    The two basic areas where the acoustic emission (AE) technique can be applied are materials research and the evaluation of structural reliability. This experimental method leads to a better understanding of fracture mechanisms and is an NDT technique particularly well suited for the study of propagating cracks. Experiments are described in which acoustic emissions were unambiguously correlated with microstructural fracture mechanisms. The advantages and limitations of the AE technique are noted.

  13. Comparative evaluation of diode laser ablation and surgical stripping technique for gingival depigmentation: A clinical and immunohistochemical study.

    PubMed

    Bakutra, Gaurav; Shankarapillai, Rajesh; Mathur, Lalit; Manohar, Balaji

    2017-01-01

    There are various treatment modalities to remove the black patches of melanin pigmentation. The aim of the study is to clinically compare the diode laser ablation and surgical stripping technique for gingival depigmentation and to evaluate their effect on the histological changes in melanocyte activity. A total of 40 sites of 20 patients with bilateral melanin hyperpigmentation were treated with the surgical stripping and diode laser ablation technique. Change in Hedin index score, change in area of pigmentation using image analyzing software, pain perception, patient preference of treatment were recorded. All 40 sites were selected for immunohistochemical analysis using HMB-45 immunohistochemical marker. At 12 months post-operative visit, in all sites, repigmentation was observed with different grades of Hedin index. Paired t -test, analysis of variance, and Chi-square tests were used for statistical analysis. Repigmentation in surgical stripping is significantly lesser compared to laser ablation. Lesser numbers of melanocytes were found on immunohistological examination at 12 months postoperatively. Comparison for patient preference and pain indices give statistically significant values for diode laser techniques. Gingival hyperpigmentation is effectively managed by diode laser ablation technique and surgical stripping method. In this study, surgical stripping technique found to be better compared to diode laser ablation.

  14. Comparative evaluation of diode laser ablation and surgical stripping technique for gingival depigmentation: A clinical and immunohistochemical study

    PubMed Central

    Bakutra, Gaurav; Shankarapillai, Rajesh; Mathur, Lalit; Manohar, Balaji

    2017-01-01

    Introduction: There are various treatment modalities to remove the black patches of melanin pigmentation. The aim of the study is to clinically compare the diode laser ablation and surgical stripping technique for gingival depigmentation and to evaluate their effect on the histological changes in melanocyte activity. Materials and Methods: A total of 40 sites of 20 patients with bilateral melanin hyperpigmentation were treated with the surgical stripping and diode laser ablation technique. Change in Hedin index score, change in area of pigmentation using image analyzing software, pain perception, patient preference of treatment were recorded. All 40 sites were selected for immunohistochemical analysis using HMB-45 immunohistochemical marker. Results: At 12 months post-operative visit, in all sites, repigmentation was observed with different grades of Hedin index. Paired t-test, analysis of variance, and Chi-square tests were used for statistical analysis. Repigmentation in surgical stripping is significantly lesser compared to laser ablation. Lesser numbers of melanocytes were found on immunohistological examination at 12 months postoperatively. Comparison for patient preference and pain indices give statistically significant values for diode laser techniques. Conclusion: Gingival hyperpigmentation is effectively managed by diode laser ablation technique and surgical stripping method. In this study, surgical stripping technique found to be better compared to diode laser ablation. PMID:28539864

  15. The effect of various veneering techniques on the marginal fit of zirconia copings

    PubMed Central

    Torabi, Kianoosh; Vojdani, Mahroo; Giti, Rashin; Pardis, Soheil

    2015-01-01

    PURPOSE This study aimed to evaluate the fit of zirconia ceramics before and after veneering, using 3 different veneering processes (layering, press-over, and CAD-on techniques). MATERIALS AND METHODS Thirty standardized zirconia CAD/CAM frameworks were constructed and divided into three groups of 10 each. The first group was veneered using the traditional layering technique. Press-over and CAD-on techniques were used to veneer second and third groups. The marginal gap of specimens was measured before and after veneering process at 18 sites on the master die using a digital microscope. Paired t-test was used to evaluate mean marginal gap changes. One-way ANOVA and post hoc tests were also employed for comparison among 3 groups (α=.05). RESULTS Marginal gap of 3 groups was increased after porcelain veneering. The mean marginal gap values after veneering in the layering group (63.06 µm) was higher than press-over (50.64 µm) and CAD-on (51.50 µm) veneered groups (P<.001). CONCLUSION Three veneering methods altered the marginal fit of zirconia copings. Conventional layering technique increased the marginal gap of zirconia framework more than pressing and CAD-on techniques. All ceramic crowns made through three different veneering methods revealed clinically acceptable marginal fit. PMID:26140175

  16. Radioactive nondestructive test method

    NASA Technical Reports Server (NTRS)

    Obrien, J. R.; Pullen, K. E.

    1971-01-01

    Various radioisotope techniques were used as diagnostic tools for determining the performance of spacecraft propulsion feed system elements. Applications were studied in four tasks. The first two required experimental testing involving the propellant liquid oxygen difluoride (OF2): the neutron activation analysis of dissolved or suspended metals, and the use of radioactive tracers to evaluate the probability of constrictions in passive components (orifices and filters) becoming clogged by matter dissolved or suspended in the OF2. The other tasks were an appraisal of the applicability of radioisotope techniques to problems arising from the exposure of components to liquid/gas combinations, and an assessment of the applicability of the techniques to other propellants.

  17. Evaluation of analysis techniques for low frequency interior noise and vibration of commercial aircraft

    NASA Technical Reports Server (NTRS)

    Landmann, A. E.; Tillema, H. F.; Marshall, S. E.

    1989-01-01

    The application of selected analysis techniques to low frequency cabin noise associated with advanced propeller engine installations is evaluated. Three design analysis techniques were chosen for evaluation including finite element analysis, statistical energy analysis (SEA), and a power flow method using element of SEA (computer program Propeller Aircraft Interior Noise). An overview of the three procedures is provided. Data from tests of a 727 airplane (modified to accept a propeller engine) were used to compare with predictions. Comparisons of predicted and measured levels at the end of the first year's effort showed reasonable agreement leading to the conclusion that each technique had value for propeller engine noise predictions on large commercial transports. However, variations in agreement were large enough to remain cautious and to lead to recommendations for further work with each technique. Assessment of the second year's results leads to the conclusion that the selected techniques can accurately predict trends and can be useful to a designer, but that absolute level predictions remain unreliable due to complexity of the aircraft structure and low modal densities.

  18. Analytic and experimental evaluation of flowing air test conditions for selected metallics in a shuttle TPS application

    NASA Technical Reports Server (NTRS)

    Schaefer, J. W.; Tong, H.; Clark, K. J.; Suchsland, K. E.; Neuner, G. J.

    1975-01-01

    A detailed experimental and analytical evaluation was performed to define the response of TD nickel chromium alloy (20 percent chromium) and coated columbium (R512E on CB-752 and VH-109 on WC129Y) to shuttle orbiter reentry heating. Flight conditions important to the response of these thermal protection system (TPS) materials were calculated, and test conditions appropriate to simulation of these flight conditions in flowing air ground test facilities were defined. The response characteristics of these metallics were then evaluated for the flight and representative ground test conditions by analytical techniques employing appropriate thermochemical and thermal response computer codes and by experimental techniques employing an arc heater flowing air test facility and flat face stagnation point and wedge test models. These results were analyzed to define the ground test requirements to obtain valid TPS response characteristics for application to flight. For both material types in the range of conditions appropriate to the shuttle application, the surface thermochemical response resulted in a small rate of change of mass and a negligible energy contribution. The thermal response in terms of surface temperature was controlled by the net heat flux to the surface; this net flux was influenced significantly by the surface catalycity and surface emissivity. The surface catalycity must be accounted for in defining simulation test conditions so that proper heat flux levels to, and therefore surface temperatures of, the test samples are achieved.

  19. Evaluation of Oil-Industry Stimulation Practices for Engineered Geothermal Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peter Van Dyke; Leen Weijers; Ann Robertson-Tait

    Geothermal energy extraction is typically achieved by use of long open-hole intervals in an attempt to connect the well with the greatest possible rock mass. This presents a problem for the development of Enhanced (Engineered) Geothermal Systems (EGS), owing to the challenge of obtaining uniform stimulation throughout the open-hole interval. Fluids are often injected in only a fraction of that interval, reducing heat transfer efficiency and increasing energy cost. Pinnacle Technologies, Inc. and GeothermEx, Inc. evaluated a variety of techniques and methods that are commonly used for hydraulic fracturing of oil and gas wells to increase and evaluate stimulation effectivenessmore » in EGS wells. Headed by Leen Weijers, formerly Manager of Technical Development at Pinnacle Technologies, Inc., the project ran from August 1, 2004 to July 31, 2006 in two one-year periods to address the following tasks and milestones: 1) Analyze stimulation results from the closest oil-field equivalents for EGS applications in the United States (e.g., the Barnett Shale in North Texas) (section 3 on page 8). Pinnacle Technologies, Inc. has collected fracture growth data from thousands of stimulations (section 3.1 on page 12). This data was further evaluated in the context of: a) Identifying techniques best suited to developing a stimulated EGS fracture network (section 3.2 on page 29), and b) quantifying the growth of the network under various conditions to develop a calibrated model for fracture network growth (section 3.3 on page 30). The developed model can be used to design optimized EGS fracture networks that maximize contact with the heat source and minimize short-circuiting (section 3.4 on page 38). 2) Evaluate methods used in oil field applications to improve fluid diversion and penetration and determine their applicability to EGS (section 4 on page 50). These methods include, but are not limited to: a) Stimulation strategies (propped fracturing versus water fracturing versus injecting fluid below fracturing gradients) (section 4.1 on page 50); b) zonal isolation methods (by use of perforated casing or packers) (section 4.2 on page 57); c) fracture re-orientation and fracture network growth techniques (e.g., by use of alternating high- and low-rate injections) (section 4.4 on page 74); and d) fluid diversion methods (by use of the SurgiFrac technique, the StimGun perforation technique, or stress shadowing). This project task is to be completed in the first project year, enabling the most promising techniques to be field tested and evaluated in the second project year. 3) Study the applicability of the methods listed above by utilizing several techniques (section 5 on page 75) including, but not limited to: a) Hydraulic Impedance Testing (HIT) to determine the location of open hydraulic fractures along a open-hole interval; b) pressure transient testing to determine reservoir permeability, pore pressure, and closure stress; and c) treatment well tilt mapping or microseismic mapping to evaluate fracture coverage. These techniques were reviewed for their potential application for EGS in the first project year (section 5.1 on page 75). This study also includes further analysis of any field testing that will be conducted in the Desert Peak area in Nevada for ORMAT Nevada, Inc. (section 5.2 on page 86), with the aim to close the loop to provide reliable calibrated fracture model results. Developed through its hydraulic fracture consulting business, techniques of Pinnacle Technologies, Inc. for stimulating and analyzing fracture growth have helped the oil and gas industry to improve hydraulic fracturing from both a technical and economic perspective. In addition to more than 30 years of experience in the development of geothermal energy for commercial power generation throughout the world, GeothermEx, Inc. brings to the project: 1) Detailed information about specific developed and potential EGS reservoirs, 2) experience with geothermal well design, completion, and testing practices, and 3) a direct connection to the Desert Peak EGS project.« less

  20. [Research progress on mechanical performance evaluation of artificial intervertebral disc].

    PubMed

    Li, Rui; Wang, Song; Liao, Zhenhua; Liu, Weiqiang

    2018-03-01

    The mechanical properties of artificial intervertebral disc (AID) are related to long-term reliability of prosthesis. There are three testing methods involved in the mechanical performance evaluation of AID based on different tools: the testing method using mechanical simulator, in vitro specimen testing method and finite element analysis method. In this study, the testing standard, testing equipment and materials of AID were firstly introduced. Then, the present status of AID static mechanical properties test (static axial compression, static axial compression-shear), dynamic mechanical properties test (dynamic axial compression, dynamic axial compression-shear), creep and stress relaxation test, device pushout test, core pushout test, subsidence test, etc. were focused on. The experimental techniques using in vitro specimen testing method and testing results of available artificial discs were summarized. The experimental methods and research status of finite element analysis were also summarized. Finally, the research trends of AID mechanical performance evaluation were forecasted. The simulator, load, dynamic cycle, motion mode, specimen and test standard would be important research fields in the future.

  1. An analysis technique for testing log grades

    Treesearch

    Carl A. Newport; William G. O' Regan

    1963-01-01

    An analytical technique that may be used in evaluating log-grading systems is described. It also provides means of comparing two or more grading systems, or a proposed change with the system from which it was developed. The total volume and computed value of lumber from each sample log are the basic data used.

  2. Development of one-step Loop-Mediated Isothermal Amplification (LAMP) for the detection of norovirus in oysters

    USDA-ARS?s Scientific Manuscript database

    The aim of this study was to develop a simple and rapid technique for detecting human norovirus (NoV). The loop-mediated isothermal amplification (LAMP) technique was evaluated and found to be sensitive, highly specific, and useful for routine oyster testing. Reverse transcription-LAMP (RT-LAMP) pri...

  3. PSYCHOLOGICAL RESEARCH IN CLASSROOM LEARNING, REPORT ON A CONFERENCE (BROMWOODS RESIDENTIAL CENTER, WASHINGTON UNIVERSITY, ST. LOUIS, MO.).

    ERIC Educational Resources Information Center

    WIENTGE, KING M., ED.; AND OTHERS

    PAPERS WERE PRESENTED AT A CONFERENCE ON CLASSROOM LEARNING ON SUCH TOPICS AS PROGRAM DESIGN, TESTING, AND OTHER EVALUATION TECHNIQUES, COMPUTER ASSISTED INSTRUCTION, PROGRAMED INSTRUCTION, SIMULATION, PACING, AND RETENTION. SEVERAL TREATED MILITARY TRAINING, ADULT LEARNING, AND ADULT-CENTERED CLASSROOM TECHNIQUES. IN ONE PAPER, THE SYSTEMS…

  4. Job Performance Aids: Research and Technology State-of-the-Art. Final Report.

    ERIC Educational Resources Information Center

    Booher, Harold R.

    Conducted as part of a major effort to test and evaluate Job Performance Aids (JPA) and their integration with Navy personnel and training systems, this study systematically reviewed and organized existing JPA techniques, related research data, and various applicable principles and concepts. One hundred and one JPA systems and techniques were…

  5. Validation of the NASA Dryden X-31 simulation and evaluation of mechanization techniques

    NASA Technical Reports Server (NTRS)

    Dickes, Edward; Kay, Jacob; Ralston, John

    1994-01-01

    This paper shall discuss the evaluation of the original Dryden X-31 aerodynamic math model, processes involved in the justification and creation of the modified data base, and comparison time history results of the model response with flight test.

  6. Evaluation of Electromagnetic Near-Field Measurement Technique as Non-Destructive Testing for Composite Structures

    NASA Astrophysics Data System (ADS)

    Raad Hussein, Alaa; Badri Albarody, Thar M.; Megat Yusoff, Puteri Sri Melor Bt

    2018-05-01

    Nowadays there is no viable non-destructive method that could detect flaws in complex composite products. Such a method could provide unique tools to allow engineers to minimize time consumption and cost during the evaluation of various product parameters without disturbing production. The latest research and development on propagation waves introduce micro, radio and millimetre waves as new potential non-destructive test methods for evaluation of mechanical flaws and prediction of failure in a product during production. This paper focuses on recent developments, usage, classification of electromagnetic waves under the range of radio frequency, millimetre and micro-waves. In addition, this paper reviews the application of propagation wave and proposed a new health monitoring technique based on Doppler Effect for vibration measurement in complex composite structures. Doppler Effect is influenced by dynamic behaviour of the composite structures and both are effect by flaws occurred inside the structure. Composite manufacturers, especially Aerospace industry are demanding these methods comprehensively inspect and evaluate the damages and defects in their products.

  7. Development of acoustic emission evaluation method for repaired prestressed concrete bridge girders.

    DOT National Transportation Integrated Search

    2011-06-01

    Acoustic emission (AE) monitoring has proven to be a useful nondestructive testing tool in ordinary reinforced concrete beams. Over the past decade, however, the technique has also been used to test other concrete structures. It has been seen that ac...

  8. Computer program determines performance efficiency of remote measuring systems

    NASA Technical Reports Server (NTRS)

    Merewether, E. K.

    1966-01-01

    Computer programs control and evaluate instrumentation system performance for numerous rocket engine test facilities and prescribe calibration and maintenance techniques to maintain the systems within process specifications. Similar programs can be written for other test equipment in an industry such as the petrochemical industry.

  9. Evaluating of NASA-Langley Research Center explosion seam welding

    NASA Technical Reports Server (NTRS)

    Otto, H. E.; Wittman, R.

    1977-01-01

    An explosion bonding technique to meet current fabrication requirements was demonstrated. A test program was conducted on explosion bonded joints, compared to fusion joints in 6061-T6 aluminum. The comparison was made in required fixtures, non-destructive testing, static strength and fatigue strength.

  10. Electromyographic evaluation of the 'vertical' dimension: the Learreta TMJ decompression test.

    PubMed

    Freire Matos, Marcelo; Durst, Andreas C; Freire Matos, Jane Luzia; Learreta, Jorge Alfonso

    2011-10-01

    The clinical observation of the incisors overbite is the most common form used to evaluate the occlusal vertical dimension (OVD); however, this technique offers poor information about the compression state of the TMJ. In order to obtain such information, it is necessary to evaluate the electrical activity of the elevator muscles using surface electromyography (EMG). In case of a compressive irritation of the joint receptors, the trigeminal nucleus returns an inhibitory motor response of the elevator muscles that can be measured. The Learreta's EMG decompression test is done by measuring the EMG response of the masticatory muscles at maximal occlusion in four different OVD positions in such a way that the reduction of the TMJ pressure, and subsequently, relief of the inhibitory motor response can be studied. The aim of this study is to illustrate this technique, its clinical use and its limitations.

  11. Evaluation and comparison of ERTS measurements of major crops and soil associations for selected test sites in the central United States. [Texas, Indiana, Kansas, Iowa, Nebraska, and North Dakota

    NASA Technical Reports Server (NTRS)

    Baumgardner, M. F. (Principal Investigator)

    1974-01-01

    The author has identified the following significant results. Multispectral scanner data obtained by ERTS-1 over six test sites in the Central United States were analyzed and interpreted. ERTS-1 data for some of the test sites were geometrically corrected and temporally overlayed. Computer-implemented pattern recognition techniques were used in the analysis of all multispectral data. These techniques were used to evaluate ERTS-1 data as a tool for soil survey. Geology maps and land use inventories were prepared by digital analysis of multispectral data. Identification and mapping of crop species and rangelands were achieved throught the analysis of 1972 and 1973 ERTS-1 data. Multiple dates of ERTS-1 data were examined to determine the variation with time of the areal extent of surface water resources on the Southern Great Plain.

  12. Application of remote sensing techniques to the geology of the bonanza volcanic center

    NASA Technical Reports Server (NTRS)

    Marrs, R. W.

    1973-01-01

    A program is reported for evaluating remote sensing as an aid to geologic mapping for the past four years. Data tested in this evaluation include color and color infrared photography, multiband photography, low sun-angle photography, thermal infrared scanner imagery, and side-looking airborne radar. The relative utility of color and color infrared photography was tested as it was used to refine geologic maps in previously mapped areas, as field photos while mapping in the field, and in making photogeologic maps prior to field mapping. The latter technique served as a test of the maximum utility of the photography. In this application the photography was used successfully to locate 75% of all faults in a portion of the geologically complex Bonanza volcanic center and to map and correctly identify 93% of all Quaternary deposits and 62% of all areas of Tertiary volcanic outcrop in the area.

  13. Flight tests for the assessment of task performance and control activity

    NASA Technical Reports Server (NTRS)

    Pausder, H. J.; Hummes, D.

    1982-01-01

    The tests were performed with the helicopters BO 105 and UH-1D. Closely connected with tactical demands the six test pilots' task was to minimize the time and the altitude over the obstacles. The data reduction yields statistical evaluation parameters describing the control activity of the pilots and the achieved task performance. The results are shown in form of evaluation diagrams. Additionally dolphin tests with varied control strategy were performed to get more insight into the influence of control techniques. From these test results recommendations can be derived to emphasize the direct force control and to reduce the collective to pitch crosscoupling for the dolphin.

  14. Evaluation of nondestructive testing techniques for the space shuttle nonmetallic thermal protection system

    NASA Technical Reports Server (NTRS)

    Tiede, D. A.

    1972-01-01

    A program was conducted to evaluate nondestructive analysis techniques for the detection of defects in rigidized surface insulation (a candidate material for the Space Shuttle thermal protection system). Uncoated, coated, and coated and bonded samples with internal defects (voids, cracks, delaminations, density variations, and moisture content), coating defects (holes, cracks, thickness variations, and loss of adhesion), and bondline defects (voids and unbonds) were inspected by X-ray radiography, acoustic, microwave, high-frequency ultrasonic, beta backscatter, thermal, holographic, and visual techniques. The detectability of each type of defect was determined for each technique (when applicable). A possible relationship between microwave reflection measurements (or X-ray-radiography density measurements) and the tensile strength was established. A possible approach for in-process inspection using a combination of X-ray radiography, acoustic, microwave, and holographic techniques was recommended.

  15. Evaluation of Stress Corrosion Cracking Susceptibility Using Fracture Mechanics Techniques, Part 1. [environmental tests of aluminum alloys, stainless steels, and titanium alloys

    NASA Technical Reports Server (NTRS)

    Sprowls, D. O.; Shumaker, M. B.; Walsh, J. D.; Coursen, J. W.

    1973-01-01

    Stress corrosion cracking (SSC) tests were performed on 13 aluminum alloys, 13 precipitation hardening stainless steels, and two titanium 6Al-4V alloy forgings to compare fracture mechanics techniques with the conventional smooth specimen procedures. Commercially fabricated plate and rolled or forged bars 2 to 2.5-in. thick were tested. Exposures were conducted outdoors in a seacoast atmosphere and in an inland industrial atmosphere to relate the accelerated tests with service type environments. With the fracture mechanics technique tests were made chiefly on bolt loaded fatigue precracked compact tension specimens of the type used for plane-strain fracture toughness tests. Additional tests of the aluminum alloy were performed on ring loaded compact tension specimens and on bolt loaded double cantilever beams. For the smooth specimen procedure 0.125-in. dia. tensile specimens were loaded axially in constant deformation type frames. For both aluminum and steel alloys comparative SCC growth rates obtained from tests of precracked specimens provide an additional useful characterization of the SCC behavior of an alloy.

  16. Retinal Image Simulation of Subjective Refraction Techniques.

    PubMed

    Perches, Sara; Collados, M Victoria; Ares, Jorge

    2016-01-01

    Refraction techniques make it possible to determine the most appropriate sphero-cylindrical lens prescription to achieve the best possible visual quality. Among these techniques, subjective refraction (i.e., patient's response-guided refraction) is the most commonly used approach. In this context, this paper's main goal is to present a simulation software that implements in a virtual manner various subjective-refraction techniques--including Jackson's Cross-Cylinder test (JCC)--relying all on the observation of computer-generated retinal images. This software has also been used to evaluate visual quality when the JCC test is performed in multifocal-contact-lens wearers. The results reveal this software's usefulness to simulate the retinal image quality that a particular visual compensation provides. Moreover, it can help to gain a deeper insight and to improve existing refraction techniques and it can be used for simulated training.

  17. Density-based empirical likelihood procedures for testing symmetry of data distributions and K-sample comparisons.

    PubMed

    Vexler, Albert; Tanajian, Hovig; Hutson, Alan D

    In practice, parametric likelihood-ratio techniques are powerful statistical tools. In this article, we propose and examine novel and simple distribution-free test statistics that efficiently approximate parametric likelihood ratios to analyze and compare distributions of K groups of observations. Using the density-based empirical likelihood methodology, we develop a Stata package that applies to a test for symmetry of data distributions and compares K -sample distributions. Recognizing that recent statistical software packages do not sufficiently address K -sample nonparametric comparisons of data distributions, we propose a new Stata command, vxdbel, to execute exact density-based empirical likelihood-ratio tests using K samples. To calculate p -values of the proposed tests, we use the following methods: 1) a classical technique based on Monte Carlo p -value evaluations; 2) an interpolation technique based on tabulated critical values; and 3) a new hybrid technique that combines methods 1 and 2. The third, cutting-edge method is shown to be very efficient in the context of exact-test p -value computations. This Bayesian-type method considers tabulated critical values as prior information and Monte Carlo generations of test statistic values as data used to depict the likelihood function. In this case, a nonparametric Bayesian method is proposed to compute critical values of exact tests.

  18. Eccentric overload training for patients with chronic Achilles tendon pain--a randomised controlled study with reliability testing of the evaluation methods.

    PubMed

    Silbernagel, K G; Thomeé, R; Thomeé, P; Karlsson, J

    2001-08-01

    The purpose was to examine the reliability of measurement techniques and evaluate the effect of a treatment protocol including eccentric overload for patients with chronic pain from the Achilles tendon. Thirty-two patients with proximal achillodynia (44 involved Achilles tendons) participated in tests for reliability measures. No significant differences and strong (r=0.56-0.72) or very strong (r=0.90-0.93) correlations were found between pre-tests, except for the documentation of pain at rest (P<0.008, r=0.45). To evaluate the effect of a 12-week treatment protocol for patients with chronic proximal achillodynia (pain longer than three months) 40 patients (57 involved Achilles tendons) with a mean age of 45 years (range 19-77) were randomised into an experiment group (n=22) and a control group (n=18). Evaluations were performed after six weeks of treatment and after three and six months. The evaluations (including the pre-tests), performed by a physical therapist unaware of the group the patients belonged to, consisted of a questionnaire, a range of motion test, a jumping test, a toe-raise test, a pain on palpation test and pain evaluation during jumping, toe-raises and at rest. A follow-up was also performed after one year. There were no significant differences between groups at any of the evaluations, except that the experiment group jumped significantly lower than the control group at the six-week evaluation. There was, however, an overall better result for the experiment group with significant improvements in plantar flexion, and reduction in pain on palpation, number of patients having pain during walking, having periods when asymptomatic and having swollen Achilles tendon. The controls did not show such changes. Furthermore, at the one-year follow-up there were significantly more patients in the experiment group, compared with the control group, that were satisfied with their present physical activity level, considered themselves fully recovered, and had no pain during or after physical activity. The measurement techniques and the treatment protocol with eccentric overload used in the present study can be recommended for patients with chronic pain from the Achilles tendon.

  19. NDT detection and quantification of induced defects on composite helicopter rotor blade and UAV wing sections

    NASA Astrophysics Data System (ADS)

    Findeis, Dirk; Gryzagoridis, Jasson; Musonda, Vincent

    2008-09-01

    Digital Shearography and Infrared Thermography (IRT) techniques were employed to test non-destructively samples from aircraft structures of composite material nature. Background information on the techniques is presented and it is noted that much of the inspection work reviewed in the literature has focused on qualitative evaluation of the defects rather than quantitative. There is however, need to quantify the defects if the threshold rejection criterion of whether the component inspected is fit for service has to be established. In this paper an attempt to quantify induced defects on a helicopter main rotor blade and Unmanned Aerospace Vehicle (UAV) composite material is presented. The fringe patterns exhibited by Digital Shearography were used to quantify the defects by relating the number of fringes created to the depth of the defect or flaw. Qualitative evaluation of defects with IRT was achieved through a hot spot temperature indication above the flaw on the surface of the material. The results of the work indicate that the Shearographic technique proved to be more sensitive than the IRT technique. It should be mentioned that there is "no set standard procedure" tailored for testing of composites. Each composite material tested is more likely to respond differently to defect detection and this depends generally on the component geometry and a suitable selection of the loading system to suit a particular test. The experimental procedure that is reported in this paper can be used as a basis for designing a testing or calibration procedure for defects detection on any particular composite material component or structure.

  20. Field evaluation of commercial off-the-shelf spatial repellents against the Asian Tiger Mosquito, Aedes albopictus (Skuse), and the potential for use during deployment.

    USDA-ARS?s Scientific Manuscript database

    The Testing and Evaluation Department of the US Navy Entomology Center of Excellence (NECE), Naval Air Station, Jacksonville, Florida, is dedicated to the evaluation of novel equipment and vector control techniques to provide guidance on effective protection measures against human pathogens transmit...

  1. Evaluation of the Communication Between Arachnoid Cysts and Neighboring Cerebrospinal Fluid Spaces by T2W 3D-SPACE With Variant Flip-Angle Technique at 3 T.

    PubMed

    Algin, Oktay

    2018-05-21

    Phase-contrast cine magnetic resonance imaging (PC-MRI) is a widely used technique for determination of possible communication of arachnoid cysts (ACs). Three-dimensional (3D) sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) technique is a relatively new method for 3D isotropic scanning of the entire cranium within a short time. In this research, the usage of the 3D-SPACE technique in differentiation of communicating or noncommunicating type ACs was evaluated. Thirty-five ACs in 34 patients were retrospectively examined. The 3D-SPACE, PC-MRI, and contrast material-enhanced cisternography (if present) images of the patients were analyzed. Each cyst was described according to cyst size/location, third ventricle diameter, Evans index, and presence of hydrocephalus. Communication was defined as absent (score 0), suspected (score 1), or present (score 2) on each sequence. Results of PC-MRI or cisternography (if available) examinations were used as criterion standard techniques to categorize all cysts as communicating or noncommunicating type. The results of 3D-SPACE were compared with criterion standard techniques. The comparisons between groups were performed using Mann-Whitney and Fisher exact tests. For demonstration of communication status of the cysts, criterion standard test results and 3D-SPACE findings were almost in perfect harmony (κ[95% confidence interval: 0.94]; P < 0.001). When evaluating the communicative properties, 3D-SPACE findings correlated with other final results at a rate of 97%. There is a positive correlation with third ventricular diameters and Evans index for all patients (r = 0.77, P < 0.001). For other analyzed variables, there is no significant difference or correlation between the groups. The 3D-SPACE technique is an easy, useful, and noninvasive alternative for the evaluation of morphology, topographical relationships, and communication status of ACs.

  2. Techniques for control of long-term reliability of complex integrated circuits. I - Reliability assurance by test vehicle qualification.

    NASA Technical Reports Server (NTRS)

    Van Vonno, N. W.

    1972-01-01

    Development of an alternate approach to the conventional methods of reliability assurance for large-scale integrated circuits. The product treated is a large-scale T squared L array designed for space applications. The concept used is that of qualification of product by evaluation of the basic processing used in fabricating the product, providing an insight into its potential reliability. Test vehicles are described which enable evaluation of device characteristics, surface condition, and various parameters of the two-level metallization system used. Evaluation of these test vehicles is performed on a lot qualification basis, with the lot consisting of one wafer. Assembled test vehicles are evaluated by high temperature stress at 300 C for short time durations. Stressing at these temperatures provides a rapid method of evaluation and permits a go/no go decision to be made on the wafer lot in a timely fashion.

  3. A 100-Year Review: Sensory analysis of milk.

    PubMed

    Schiano, A N; Harwood, W S; Drake, M A

    2017-12-01

    Evaluation of the sensory characteristics of food products has been, and will continue to be, the ultimate method for evaluating product quality. Sensory quality is a parameter that can be evaluated only by humans and consists of a series of tests or tools that can be applied objectively or subjectively within the constructs of carefully selected testing procedures and parameters. Depending on the chosen test, evaluators are able to probe areas of interest that are intrinsic product attributes (e.g., flavor profiles and off-flavors) as well as extrinsic measures (e.g., market penetration and consumer perception). This review outlines the literature pertaining to relevant testing procedures and studies of the history of sensory analysis of fluid milk. In addition, evaluation methods outside of traditional sensory techniques and future outlooks on the subject of sensory analysis of fluid milk are explored and presented. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  4. Energetic Materials Center Report--Small-Scale Safety and Thermal Testing Evaluation of Butyl Nitrate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsu, Peter C.; Reynolds, John G.

    2013-04-26

    Butyl Nitrate (BN) was examined by Small-Scale Safety and Thermal (SSST) Testing techniques to determine its sensitivity to impact, friction, spark and thermal exposure simulating handling and storage conditions. Under the conditions tested, the BN exhibits thermal sensitivity above 150 °C, and does not exhibit sensitive to impact, friction or spark.

  5. Hypothesis Generation, Evaluation, and Memory Abilities in Adult Human Concept Learning.

    ERIC Educational Resources Information Center

    Cason, Carolyn L.; And Others

    Studies were made between performance on tests of mental abilities and concept learning tasks; it is pointed out that the researcher is usually confronted with administering large batteries of tests of mental abilities and then analyzing his results with one of the factor analytic techniques. An information process analysis of tests of mental…

  6. The Evaluation of Oral/Aural Skills within the BA Finals Examination: Analysis and Interim Proposals.

    ERIC Educational Resources Information Center

    Crawshaw, Robert

    An examination of the principles and techniques of oral testing in British university-level final examinations in modern languages discusses: (1) the shortcomings of present oral testing procedures; (2) the theoretical controversy surrounding the design and value of oral proficiency tests, arising from research in English as a second language…

  7. SIRU utilization. Volume 1: Theory, development and test evaluation

    NASA Technical Reports Server (NTRS)

    Musoff, H.

    1974-01-01

    The theory, development, and test evaluations of the Strapdown Inertial Reference Unit (SIRU) are discussed. The statistical failure detection and isolation, single position calibration, and self alignment techniques are emphasized. Circuit diagrams of the system components are provided. Mathematical models are developed to show the performance characteristics of the subsystems. Specific areas of the utilization program are identified as: (1) error source propagation characteristics and (2) local level navigation performance demonstrations.

  8. Solderability test system

    DOEpatents

    Yost, F.; Hosking, F.M.; Jellison, J.L.; Short, B.; Giversen, T.; Reed, J.R.

    1998-10-27

    A new test method to quantify capillary flow solderability on a printed wiring board surface finish. The test is based on solder flow from a pad onto narrow strips or lines. A test procedure and video image analysis technique were developed for conducting the test and evaluating the data. Feasibility tests revealed that the wetted distance was sensitive to the ratio of pad radius to line width (l/r), solder volume, and flux predry time. 11 figs.

  9. A study of space shuttle structural integrity test and assessment. Part 1

    NASA Technical Reports Server (NTRS)

    Anderson, R. E.; Poe, R. G.

    1972-01-01

    The ultrasonics technique for assessing the structural integrity of the primary surface of the space shuttle vehicles is discussed and evaluated. Analysis was made of transducers, transducer coupling test structure fabrication, flaws, and ultrasonic testing. Graphs of microphone response curves from the initial noise tests, accelerometer response curves from the final noise tests, and microphone curves from the final noise tests are included along with a glossary, bibliography, and results.

  10. Metabolic myopathies: functional evaluation by different exercise testing approaches.

    PubMed

    Volpi, L; Ricci, G; Orsucci, D; Alessi, R; Bertolucci, F; Piazza, S; Simoncini, C; Mancuso, M; Siciliano, G

    2011-08-01

    Metabolic myopathies are a clinically and etiologically heterogeneous group of disorders due to defects in muscular energy metabolism. They include glycogen storage diseases, fatty acid oxidation defects, and mitochondrial disorders. The typical manifestations of a metabolic myopathy are exercise-induced myalgias, exercise intolerance, and cramps. Evaluating subjects with such symptoms is not easy because of the frequent lack of clinical features. Exercise tests are, therefore, reliable screening tools. Here, we discuss the possible role of such exercise testing techniques in the diagnostic approach of a patient with suspected metabolic myopathy.

  11. Current approach in the diagnosis and management of posterior uveitis

    PubMed Central

    Sudharshan, S; Ganesh, Sudha K; Biswas, Jyotrimay

    2010-01-01

    Posterior uveitic entities are varied entities that are infective or non-infective in etiology. They can affect the adjacent structures such as the retina, vitreous, optic nerve head and retinal blood vessels. Thorough clinical evaluation gives a clue to the diagnosis while ancillary investigations and laboratory tests assist in confirming the diagnosis. Newer evolving techniques in the investigations and management have increased the diagnostic yield. In case of diagnostic dilemma, intraocular fluid evaluation for polymerase chain testing for the genome and antibody testing against the causative agent provide greater diagnostic ability. PMID:20029144

  12. Comparison of marginal and internal adaptation of copings fabricated from three different fabrication techniques: An in vitro study.

    PubMed

    Arora, Aman; Yadav, Avneet; Upadhyaya, Viram; Jain, Prachi; Verma, Mrinalini

    2018-01-01

    The purpose of this study was to compare the marginal and internal adaptation of cobalt-chromium (Co-Cr) copings fabricated from conventional wax pattern, three-dimensional (3D)-printed resin pattern, and laser sintering technique. A total of thirty copings were made, out of which ten copings were made from 3D-printed resin pattern (Group A), ten from inlay wax pattern (Group B), and ten copings were obtained from direct metal laser sintering (DMLS) technique (Group C). All the thirty samples were seated on their respective dies and sectioned carefully using a laser jet cutter and were evaluated for marginal and internal gaps at the predetermined areas using a stereomicroscope. The values were then analyzed using one-way ANOVA test and post hoc Bonferroni test. One-way ANOVA showed lowest mean marginal discrepancy for DMLS and highest value for copings fabricated from inlay wax. The values for internal discrepancy were highest for DMLS (169.38) and lowest for 3D-printed resin pattern fabricated copings (133.87). Post hoc Bonferroni test for both marginal and internal discrepancies showed nonsignificant difference when Group A was compared to Group B ( P > 0.05) and significant when Group A was compared with Group C ( P < 0.05). Group B showed significant difference ( P < 0.05) when compared with Group C. Marginal and internal discrepancies of all the three casting techniques were within clinically acceptable values. Marginal fit of DMLS was superior as compared to other two techniques, whereas when internal fit was evaluated, conventional technique showed the best internal fit.

  13. Improved methods for distribution loss evaluation. Volume 1: analytic and evaluative techniques. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flinn, D.G.; Hall, S.; Morris, J.

    This volume describes the background research, the application of the proposed loss evaluation techniques, and the results. The research identified present loss calculation methods as appropriate, provided care was taken to represent the various system elements in sufficient detail. The literature search of past methods and typical data revealed that extreme caution in using typical values (load factor, etc.) should be taken to ensure that all factors were referred to the same time base (daily, weekly, etc.). The performance of the method (and computer program) proposed in this project was determined by comparison of results with a rigorous evaluation ofmore » losses on the Salt River Project system. This rigorous evaluation used statistical modeling of the entire system as well as explicit enumeration of all substation and distribution transformers. Further tests were conducted at Public Service Electric and Gas of New Jersey to check the appropriateness of the methods in a northern environment. Finally sensitivity tests indicated data elements inaccuracy of which would most affect the determination of losses using the method developed in this project.« less

  14. 78 FR 49516 - Agency Information Collection Activities: Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-14

    ... experiment with and evaluate several promising ideas related to improving the quality of children's health... evaluate the impact of a model pediatric electronic health record. Category E grantees are testing other... descriptive and inferential techniques appropriate to answering questions about outcomes and impacts...

  15. Duct Leakage Repeatability Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, Iain; Sherman, Max

    2014-08-01

    The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the twomore » duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.« less

  16. 78 FR 75353 - Agency Information Collection Activities: Proposed Collection: Public Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-11

    ... cognitive interviews, focus groups, usability tests, field tests/pilot interviews, and experimental research... as more basic research on response errors in surveys. HRSA staff use various techniques to evaluate... interview structure consists of respondents first answering a draft survey question and then providing...

  17. Evaluation of wheelchair resistive forces during straight and turning trajectories across different wheelchair configurations using free-wheeling coast-down test.

    PubMed

    Lin, Jui-Te; Huang, Morris; Sprigle, Stephen

    2015-01-01

    The purpose of this study was to develop a simple approach to evaluate resistive frictional forces acting on manual wheelchairs (MWCs) during straight and turning maneuvers. Using a dummy-occupied MWC, decelerations were measured via axle-mounted encoders during a coast-down protocol that included straight trajectories and fixed-wheel turns. Eight coast-down trials were conducted to test repeatability and repeated on separate days to evaluate reliability. Without changing the inertia of the MWC system, three tire inflations were chosen to evaluate the sensitivity in discerning deceleration differences using effect sizes. The technique was also deployed to investigate the effect of different MWC masses and weight distributions on resistive forces. Results showed that the proposed coast-down technique had good repeatability and reliability in measuring decelerations and had good sensitivity in discerning differences in tire inflation, especially during turning. The results also indicated that increased loading on drive wheels reduced resistive losses in straight trajectories while increasing resistive losses during turning. During turning trajectories, the presence of tire scrub contributes significantly to the amount of resistive force. Overall, this new coast-down technique demonstrates satisfactory repeatability and sensitivity for detecting deceleration changes during straight and turning trajectories, indicating that it can be used to evaluate resistive loss of different MWC configurations and maneuvers.

  18. Geophysical background and as-built target characteristics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allen, J.W.

    1994-09-01

    The US Department of Energy (DOE) Grand Junction Projects Office (GJPO) has provided a facility for DOE, other Government agencies, and the private sector to evaluate and document the utility of specific geophysical measurement techniques for detecting and defining cultural and environmental targets. This facility is the Rabbit Valley Geophysics Performance Evaluation Range (GPER). Geophysical surveys prior to the fiscal year (FY) 1994 construction of new test cells showed the primary test area to be relatively homogeneous and free from natural or man-made artifacts, which would generate spurious responses in performance evaluation data. Construction of nine new cell areas inmore » Rabbit Valley was completed in June 1994 and resulted in the emplacement of approximately 150 discrete targets selected for their physical and electrical properties. These targets and their geophysical environment provide a broad range of performance evaluation parameters from ``very easy to detect`` to ``challenging to the most advanced systems.`` Use of nonintrusive investigative techniques represents a significant improvement over intrusive characterization methods, such as drilling or excavation, because there is no danger of exposing personnel to possible hazardous materials and no risk of releasing or spreading contamination through the characterization activity. Nonintrusive geophysical techniques provide the ability to infer near-surface structure and waste characteristics from measurements of physical properties associated with those targets.« less

  19. Phenotypic and genotypic detection of Candida albicans and Candida dubliniensis strains isolated from oral mucosa of AIDS pediatric patients

    PubMed Central

    Livério, Harisson Oliveira; Ruiz, Luciana da Silva; de Freitas, Roseli Santos; Nishikaku, Angela; de Souza, Ana Clara; Paula, Claudete Rodrigues; Domaneschi, Carina

    2017-01-01

    ABSTRACT The aim of this study was to assess a collection of yeasts to verify the presence of Candida dubliniensis among strains isolated from the oral mucosa of AIDS pediatric patients which were initially characterized as Candida albicans by the traditional phenotypic method, as well as to evaluate the main phenotypic methods used in the discrimination between the two species and confirm the identification through genotypic techniques, i.e., DNA sequencing. Twenty-nine samples of C. albicans isolated from this population and kept in a fungi collection were evaluated and re-characterized. In order to differentiate the two species, phenotypic tests (Thermotolerance tests, Chromogenic medium, Staib agar, Tobacco agar, Hypertonic medium) were performed and genotypic techniques using DNA sequencing were employed for confirmation of isolated species. Susceptibility and specificity were calculated for each test. No phenotypic test alone was sufficient to provide definitive identification of C. dubliniensis or C. albicans, as opposed to results of molecular tests. After amplification and sequencing of specific regions of the 29 studied strains, 93.1% of the isolates were identified as C. albicans and 6.9% as C. dubliniensis. The Staib agar assay showed a higher susceptibility (96.3%) in comparison with other phenotypic techniques. Therefore, genotypic methods are indispensable for the conclusive identification and differentiation between these species. PMID:28423089

  20. Phenotypic and genotypic detection of Candida albicans and Candida dubliniensis strains isolated from oral mucosa of AIDS pediatric patients.

    PubMed

    Livério, Harisson Oliveira; Ruiz, Luciana da Silva; Freitas, Roseli Santos de; Nishikaku, Angela; Souza, Ana Clara de; Paula, Claudete Rodrigues; Domaneschi, Carina

    2017-04-13

    The aim of this study was to assess a collection of yeasts to verify the presence of Candida dubliniensis among strains isolated from the oral mucosa of AIDS pediatric patients which were initially characterized as Candida albicans by the traditional phenotypic method, as well as to evaluate the main phenotypic methods used in the discrimination between the two species and confirm the identification through genotypic techniques, i.e., DNA sequencing. Twenty-nine samples of C. albicans isolated from this population and kept in a fungi collection were evaluated and re-characterized. In order to differentiate the two species, phenotypic tests (Thermotolerance tests, Chromogenic medium, Staib agar, Tobacco agar, Hypertonic medium) were performed and genotypic techniques using DNA sequencing were employed for confirmation of isolated species. Susceptibility and specificity were calculated for each test. No phenotypic test alone was sufficient to provide definitive identification of C. dubliniensis or C. albicans, as opposed to results of molecular tests. After amplification and sequencing of specific regions of the 29 studied strains, 93.1% of the isolates were identified as C. albicans and 6.9% as C. dubliniensis. The Staib agar assay showed a higher susceptibility (96.3%) in comparison with other phenotypic techniques. Therefore, genotypic methods are indispensable for the conclusive identification and differentiation between these species.

  1. Design and development of pressure and repressurization purge system for reusable space shuttle multilayer insulation system

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The experimental determination of purge bag materials properties, development of purge bag manufacturing techniques, experimental evaluation of a subscale purge bag under simulated operating conditions and the experimental evaluation of the purge pin concept for MLI purging are discussed. The basic purge bag material, epoxy fiberglass bounded by skins of FEP Teflon, showed no significant permeability to helium flow under normal operating conditions. Purge bag small scale manufacturing tests were conducted to develop tooling and fabrication techniques for use in full scale bag manufacture. A purge bag material layup technique was developed whereby the two plys of epoxy fiberglass enclosed between skins of FEP Teflon are vacuum bag cured in an oven in a single operation. The material is cured on a tool with the shape of a purge bag half. Plastic tooling was selected for use in bag fabrication. A model purge bag 0.6 m in diameter was fabricated and subjected to a series of structural and environmental tests simulating various flight type environments. Pressure cycling tests at high (450 K) and low (200 K) temperature as well as acoustic loading tests were performed. The purge bag concept proved to be structurally sound and was used for the full scale bag detailed design model.

  2. Nanosilica coating for bonding improvements to zirconia.

    PubMed

    Chen, Chen; Chen, Gang; Xie, Haifeng; Dai, Wenyong; Zhang, Feimin

    2013-01-01

    Resin bonding to zirconia cannot be established from standard methods that are currently utilized in conventional silica-based dental ceramics. The solution-gelatin (sol-gel) process is a well developed silica-coating technique used to modify the surface of nonsilica-based ceramics. Here, we use this technique to improve resin bonding to zirconia, which we compared to zirconia surfaces treated with alumina sandblasting and tribochemical silica coating. We used the shear bond strength test to examine the effect of the various coatings on the short-term resin bonding of zirconia. Furthermore, we employed field emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, atomic force microscopy, and Fourier transform infrared spectroscopy to characterize the zirconia surfaces. Water-mist spraying was used to evaluate the durability of the coatings. To evaluate the biological safety of the experimental sol-gel silica coating, we conducted an in vitro Salmonella typhimurium reverse mutation assay (Ames mutagenicity test), cytotoxicity tests, and in vivo oral mucous membrane irritation tests. When compared to the conventional tribochemical silica coating, the experimental sol-gel silica coating provided the same shear bond strength, higher silicon contents, and better durability. Moreover, we observed no apparent mutagenicity, cytotoxicity, or irritation in this study. Therefore, the sol-gel technique represents a promising method for producing silica coatings on zirconia.

  3. Nanosilica coating for bonding improvements to zirconia

    PubMed Central

    Chen, Chen; Chen, Gang; Xie, Haifeng; Dai, Wenyong; Zhang, Feimin

    2013-01-01

    Resin bonding to zirconia cannot be established from standard methods that are currently utilized in conventional silica-based dental ceramics. The solution–gelatin (sol–gel) process is a well developed silica-coating technique used to modify the surface of nonsilica-based ceramics. Here, we use this technique to improve resin bonding to zirconia, which we compared to zirconia surfaces treated with alumina sandblasting and tribochemical silica coating. We used the shear bond strength test to examine the effect of the various coatings on the short-term resin bonding of zirconia. Furthermore, we employed field emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, atomic force microscopy, and Fourier transform infrared spectroscopy to characterize the zirconia surfaces. Water–mist spraying was used to evaluate the durability of the coatings. To evaluate the biological safety of the experimental sol–gel silica coating, we conducted an in vitro Salmonella typhimurium reverse mutation assay (Ames mutagenicity test), cytotoxicity tests, and in vivo oral mucous membrane irritation tests. When compared to the conventional tribochemical silica coating, the experimental sol–gel silica coating provided the same shear bond strength, higher silicon contents, and better durability. Moreover, we observed no apparent mutagenicity, cytotoxicity, or irritation in this study. Therefore, the sol–gel technique represents a promising method for producing silica coatings on zirconia. PMID:24179333

  4. Distributed Simulation as a modelling tool for the development of a simulation-based training programme for cardiovascular specialties.

    PubMed

    Kelay, Tanika; Chan, Kah Leong; Ako, Emmanuel; Yasin, Mohammad; Costopoulos, Charis; Gold, Matthew; Kneebone, Roger K; Malik, Iqbal S; Bello, Fernando

    2017-01-01

    Distributed Simulation is the concept of portable, high-fidelity immersive simulation. Here, it is used for the development of a simulation-based training programme for cardiovascular specialities. We present an evidence base for how accessible, portable and self-contained simulated environments can be effectively utilised for the modelling, development and testing of a complex training framework and assessment methodology. Iterative user feedback through mixed-methods evaluation techniques resulted in the implementation of the training programme. Four phases were involved in the development of our immersive simulation-based training programme: ( 1) initial conceptual stage for mapping structural criteria and parameters of the simulation training framework and scenario development ( n  = 16), (2) training facility design using Distributed Simulation , (3) test cases with clinicians ( n  = 8) and collaborative design, where evaluation and user feedback involved a mixed-methods approach featuring (a) quantitative surveys to evaluate the realism and perceived educational relevance of the simulation format and framework for training and (b) qualitative semi-structured interviews to capture detailed feedback including changes and scope for development. Refinements were made iteratively to the simulation framework based on user feedback, resulting in (4) transition towards implementation of the simulation training framework, involving consistent quantitative evaluation techniques for clinicians ( n  = 62). For comparative purposes, clinicians' initial quantitative mean evaluation scores for realism of the simulation training framework, realism of the training facility and relevance for training ( n  = 8) are presented longitudinally, alongside feedback throughout the development stages from concept to delivery, including the implementation stage ( n  = 62). Initially, mean evaluation scores fluctuated from low to average, rising incrementally. This corresponded with the qualitative component, which augmented the quantitative findings; trainees' user feedback was used to perform iterative refinements to the simulation design and components (collaborative design), resulting in higher mean evaluation scores leading up to the implementation phase. Through application of innovative Distributed Simulation techniques, collaborative design, and consistent evaluation techniques from conceptual, development, and implementation stages, fully immersive simulation techniques for cardiovascular specialities are achievable and have the potential to be implemented more broadly.

  5. The contribute of DInSAR techniques to landslide hazard evaluation in mountain and hilly regions: a case study from Agno Valley (North-Eastern Italian Alps)

    NASA Astrophysics Data System (ADS)

    De Agostini, A.; Floris, M.; Pasquali, P.; Barbieri, M.; Cantone, A.; Riccardi, P.; Stevan, G.; Genevois, R.

    2012-04-01

    In the last twenty years, Differential Synthetic Aperture Radar Interferometry (DInSAR) techniques have been widely used to investigate geological processes, such as subsidence, earthquakes and landslides, through the evaluation of earth surface displacements caused by these processes. In the study of mass movements, contribution of interferometry can be limited due to the acquisition geometry of RADAR images and the rough morphology of mountain and hilly regions which represent typical landslide-prone areas. In this study, the advanced DInSAR techniques (i.e. Small Baseline Subset and Persistent Scatterers techniques), available in SARscape software, are used. These methods involve the use of multiple acquisitions stacks (large SAR temporal series) allowing improvements and refinements in landslide identification, characterization and hazard evaluation at the basin scale. Potential and limits of above mentioned techniques are outlined and discussed. The study area is the Agno Valley, located in the North-Eastern sector of Italian Alps and included in the Vicenza Province (Veneto Region, Italy). This area and the entire Vicenza Province were hit by an exceptional rainfall event on November 2010 that triggered more than 500 slope instabilities. The main aim of the work is to verify if spatial information available before the rainfall event, including ERS and ENVISAT RADAR data from 1992 to 2010, were able to predict the landslides occurred in the study area, in order to implement an effectiveness forecasting model. In the first step of the work a susceptibility analysis is carried out using landslide dataset from the IFFI project (Inventario Fenomeni Franosi in Italia, Landslide Italian Inventory) and related predisposing factors, which consist of morphometric (elevation, slope, aspect and curvature) and non-morphometric (land use, distance of roads and distance of river) factors available from the Veneto Region spatial database. Then, to test the prediction, the results of susceptibility analysis are compared with the location of landslides occurred in the study area during the November 2010 rainfall event. In the second step, results of DInSAR analysis (displacement maps over the time) are added on the prediction analysis to build up a map containing both spatial and temporal information on landslides and, as in the previous case, the prediction is tested by using November 2010 instabilities dataset. Comparison of the two tests allows to evaluate the contribution of interferometric techniques. Finally, morphometric factors and interferometric RADAR data are combined to design a preliminary analysis scheme that provide information on possible use of DInSAR techniques in landslide hazard evaluation of a given area.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Di Domenico, Giovanni, E-mail: didomenico@fe.infn.it; Cardarelli, Paolo; Taibi, Angelo

    Purpose: The quality of a radiography system is affected by several factors, a major one being the focal spot size of the x-ray tube. In fact, the measurement of such size is recognized to be of primary importance during acceptance tests and image quality evaluations of clinical radiography systems. The most common device providing an image of the focal spot emission distribution is a pin-hole camera, which requires a high tube loading in order to produce a measurable signal. This work introduces an alternative technique to obtain an image of the focal spot, through the processing of a single radiographmore » of a simple test object, acquired with a suitable magnification. Methods: The radiograph of a magnified sharp edge is a well-established method to evaluate the extension of the focal spot profile along the direction perpendicular to the edge. From a single radiograph of a circular x-ray absorber, it is possible to extract simultaneously the radial profiles of several sharp edges with different orientations. The authors propose a technique that allows to obtain an image of the focal spot through the processing of these radial profiles by means of a pseudo-CT reconstruction technique. In order to validate this technique, the reconstruction has been applied to the simulated radiographs of an ideal disk-shaped absorber, generated by various simulated focal spot distributions. Furthermore, the method has been applied to the focal spot of a commercially available mammography unit. Results: In the case of simulated radiographs, the results of the reconstructions have been compared to the original distributions, showing an excellent agreement for what regards both the overall distribution and the full width at half maximum measurements. In the case of the experimental test, the method allowed to obtain images of the focal spot that have been compared with the results obtained through standard techniques, namely, pin-hole camera and slit camera. Conclusions: The method was proven to be effective for simulated images and the results of the experimental test suggest that it could be considered as an alternative technique for focal spot distribution evaluation. The method offers the possibility to measure the actual focal spot size and emission distribution at the same exposure conditions as clinical routine, avoiding high tube loading as in the case of the pin-hole imaging technique.« less

  7. X-ray focal spot reconstruction by circular penumbra analysis-Application to digital radiography systems.

    PubMed

    Di Domenico, Giovanni; Cardarelli, Paolo; Contillo, Adriano; Taibi, Angelo; Gambaccini, Mauro

    2016-01-01

    The quality of a radiography system is affected by several factors, a major one being the focal spot size of the x-ray tube. In fact, the measurement of such size is recognized to be of primary importance during acceptance tests and image quality evaluations of clinical radiography systems. The most common device providing an image of the focal spot emission distribution is a pin-hole camera, which requires a high tube loading in order to produce a measurable signal. This work introduces an alternative technique to obtain an image of the focal spot, through the processing of a single radiograph of a simple test object, acquired with a suitable magnification. The radiograph of a magnified sharp edge is a well-established method to evaluate the extension of the focal spot profile along the direction perpendicular to the edge. From a single radiograph of a circular x-ray absorber, it is possible to extract simultaneously the radial profiles of several sharp edges with different orientations. The authors propose a technique that allows to obtain an image of the focal spot through the processing of these radial profiles by means of a pseudo-CT reconstruction technique. In order to validate this technique, the reconstruction has been applied to the simulated radiographs of an ideal disk-shaped absorber, generated by various simulated focal spot distributions. Furthermore, the method has been applied to the focal spot of a commercially available mammography unit. In the case of simulated radiographs, the results of the reconstructions have been compared to the original distributions, showing an excellent agreement for what regards both the overall distribution and the full width at half maximum measurements. In the case of the experimental test, the method allowed to obtain images of the focal spot that have been compared with the results obtained through standard techniques, namely, pin-hole camera and slit camera. The method was proven to be effective for simulated images and the results of the experimental test suggest that it could be considered as an alternative technique for focal spot distribution evaluation. The method offers the possibility to measure the actual focal spot size and emission distribution at the same exposure conditions as clinical routine, avoiding high tube loading as in the case of the pin-hole imaging technique.

  8. Clinical and arthroscopic outcome of single bundle anterior cruciate ligament reconstruction: Comparison of remnant preservation versus conventional technique.

    PubMed

    Choi, Sungwook; Kim, Myung-Ku; Kwon, Yong Suk; Kang, Hyunseong

    2017-10-01

    The purpose of this study was to compare the clinical outcomes and second-look arthroscopic findings of remnant preservation technique with those of conventional anterior cruciate ligament (ACL) reconstruction in single bundle ACL reconstructions. One hundred sixty two consecutive patients underwent ACL reconstruction by one surgeon, with 93 patients receiving remnant preservation technique (Group A) and 69 patients receiving conventional ACL reconstruction (Group B). The mean follow-up was 15months. Clinical outcomes were assessed using Lysholm scores and the International Knee Documentation Committee form (IKDC form) evaluation. Post-operative knee stability was evaluated through manual knee laxity evaluation, pivot-shift test, and a Telos device. Differences in post-operative stability (manual knee laxity, pivot shift test and Telos device) were not significant between the groups (p=0.681, p=0.610, p=0.696). And also no significant differences were noted with respect to the IKDC form and the latest Lysholm scores. But in the second-look arthroscopic findings, synovial coverage was confirmed to be excellent in 36% (22/61) of Group A patients and 23% (7/30) of Group B patients. ACL reconstruction with both techniques was found to result in acceptable stability, clinical outcomes and second-look arthroscopic findings. With regard to synovial coverage, the remnant reservation techniques were found to be superior to conventional ACL reconstruction. Level III, retrospective comparative study. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques.

    PubMed

    Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T

    2016-08-01

    Currently no data comparing the denture base adaptation of CAD-CAM and conventional denture processing techniques have been reported. The purpose of this in vitro study was to compare the denture base adaptation of pack and press, pour, injection, and CAD-CAM techniques for fabricating dentures to determine which process produces the most accurate and reproducible adaptation. A definitive cast was duplicated to create 40 gypsum casts that were laser scanned before any fabrication procedures were initiated. A master denture was made using the CAD-CAM process and was then used to create a putty mold for the fabrication of 30 standardized wax festooned dentures, 10 for each of the conventional processing techniques (pack and press, pour, injection). Scan files from 10 casts were sent to Global Dental Science, LLC for fabrication of the CAD-CAM test specimens. After specimens for each of the 4 techniques had been fabricated, they were hydrated for 24 hours and the intaglio surface laser scanned. The scan file of each denture was superimposed on the scan file of the corresponding preprocessing cast using surface matching software. Measurements were made at 60 locations, providing evaluation of fit discrepancies at the following areas: apex of the denture border, 6 mm from the denture border, crest of the ridge, palate, and posterior palatal seal. The use of median and interquartile range was used to assess accuracy and reproducibility. The Levine and Kruskal-Wallis analysis of variance was used to evaluate differences between processing techniques at the 5 specified locations (α=.05). The ranking of results based on median and interquartile range determined that the accuracy and reproducibility of the CAD-CAM technique was more consistently localized around zero at 3 of the 5 locations. Therefore, the CAD-CAM technique showed the best combination of accuracy and reproducibility among the tested fabrication techniques. The pack and press technique was more accurate at 2 of the 5 locations; however, its interquartile range (reproducibility) was the greatest of the 4 tested processing techniques. The pour technique was the most reproducible at 2 of the 5 locations; however, its accuracy was the lowest of the tested techniques. The CAD-CAM fabrication process was the most accurate and reproducible denture fabrication technique when compared with pack and press, pour, and injection denture base processing techniques. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. Input design for identification of aircraft stability and control derivatives

    NASA Technical Reports Server (NTRS)

    Gupta, N. K.; Hall, W. E., Jr.

    1975-01-01

    An approach for designing inputs to identify stability and control derivatives from flight test data is presented. This approach is based on finding inputs which provide the maximum possible accuracy of derivative estimates. Two techniques of input specification are implemented for this objective - a time domain technique and a frequency domain technique. The time domain technique gives the control input time history and can be used for any allowable duration of test maneuver, including those where data lengths can only be of short duration. The frequency domain technique specifies the input frequency spectrum, and is best applied for tests where extended data lengths, much longer than the time constants of the modes of interest, are possible. These technqiues are used to design inputs to identify parameters in longitudinal and lateral linear models of conventional aircraft. The constraints of aircraft response limits, such as on structural loads, are realized indirectly through a total energy constraint on the input. Tests with simulated data and theoretical predictions show that the new approaches give input signals which can provide more accurate parameter estimates than can conventional inputs of the same total energy. Results obtained indicate that the approach has been brought to the point where it should be used on flight tests for further evaluation.

  11. Dissimilar metals joint evaluation

    NASA Technical Reports Server (NTRS)

    Wakefield, M. E.; Apodaca, L. E.

    1974-01-01

    Dissimilar metals tubular joints between 2219-T851 aluminum alloy and 304L stainless steel were fabricated and tested to evaluate bonding processes. Joints were fabricated by four processes: (1) inertia (friction) weldings, where the metals are spun and forced together to create the weld; (2) explosive welding, where the metals are impacted together at high velocity; (3) co-extrusion, where the metals are extruded in contact at high temperature to promote diffusion; and (4) swaging, where residual stresses in the metals after a stretching operation maintain forced contact in mutual shear areas. Fifteen joints of each type were prepared and evaluated in a 6.35 cm (2.50 in.) O.D. size, with 0.32 cm (0.13 in.) wall thickness, and 7.6 cm (3.0 in) total length. The joints were tested to evaluate their ability to withstand pressure cycle, thermal cycle, galvanic corrosion and burst tests. Leakage tests and other non-destructive test techniques were used to evaluate the behavior of the joints, and the microstructure of the bond areas was analyzed.

  12. Validation of a new technique to detect Cryptosporidium spp. oocysts in bovine feces.

    PubMed

    Inácio, Sandra Valéria; Gomes, Jancarlo Ferreira; Oliveira, Bruno César Miranda; Falcão, Alexandre Xavier; Suzuki, Celso Tetsuo Nagase; Dos Santos, Bianca Martins; de Aquino, Monally Conceição Costa; de Paula Ribeiro, Rafaela Silva; de Assunção, Danilla Mendes; Casemiro, Pamella Almeida Freire; Meireles, Marcelo Vasconcelos; Bresciani, Katia Denise Saraiva

    2016-11-01

    Due to its important zoonotic potential, cryptosporidiosis arouses strong interest in the scientific community, because, it was initially considered a rare and opportunistic disease. The parasitological diagnosis of the causative agent of this disease, the protozoan Cryptosporidium spp., requires the use of specific techniques of concentration and permanent staining, which are laborious and costly, and are difficult to use in routine laboratory tests. In view of the above, we conducted the feasibility, development, evaluation and intralaboratory validation of a new parasitological technique for analysis in optical microscopy of Cryptosporidium spp. oocysts, called TF-Test Coccidia, using fecal samples from calves from the city of Araçatuba, São Paulo. To confirm the aforementioned parasite and prove the diagnostic efficiency of the new technique, we used two established methodologies in the scientific literature: parasite concentration by centrifugal sedimentation and negative staining with malachite green (CSN-Malachite) and Nested-PCR. We observed good effectiveness of the TF-Test Coccidia technique, being statistically equivalent to CSN-Malachite. Thus, we verified the effectiveness of the TF-Test Coccidia parasitological technique for the detection of Cryptosporidium spp. oocysts and observed good concentration and morphology of the parasite, with a low amount of debris in the fecal smear. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Flight testing of a luminescent surface pressure sensor

    NASA Technical Reports Server (NTRS)

    Mclachlan, B. G.; Bell, J. H.; Espina, J.; Gallery, J.; Gouterman, M.; Demandante, C. G. N.; Bjarke, L.

    1992-01-01

    NASA ARC has conducted flight tests of a new type of aerodynamic pressure sensor based on a luminescent surface coating. Flights were conducted at the NASA ARC-Dryden Flight Research Facility. The luminescent pressure sensor is based on a surface coating which, when illuminated with ultraviolet light, emits visible light with an intensity dependent on the local air pressure on the surface. This technique makes it possible to obtain pressure data over the entire surface of an aircraft, as opposed to conventional instrumentation, which can only make measurements at pre-selected points. The objective of the flight tests was to evaluate the effectiveness and practicality of a luminescent pressure sensor in the actual flight environment. A luminescent pressure sensor was installed on a fin, the Flight Test Fixture (FTF), that is attached to the underside of an F-104 aircraft. The response of one particular surface coating was evaluated at low supersonic Mach numbers (M = 1.0-1.6) in order to provide an initial estimate of the sensor's capabilities. This memo describes the test approach, the techniques used, and the pressure sensor's behavior under flight conditions. A direct comparison between data provided by the luminescent pressure sensor and that produced by conventional pressure instrumentation shows that the luminescent sensor can provide quantitative data under flight conditions. However, the test results also show that the sensor has a number of limitations which must be addressed if this technique is to prove useful in the flight environment.

  14. Evaluation of twenty-two rapid antigen detection tests in the diagnosis of Equine Influenza caused by viruses of H3N8 subtype.

    PubMed

    Yamanaka, Takashi; Nemoto, Manabu; Bannai, Hiroshi; Tsujimura, Koji; Kondo, Takashi; Matsumura, Tomio; Gildea, Sarah; Cullinane, Ann

    2016-03-01

    Equine influenza (EI) is a highly contagious disease caused by viruses of the H3N8 subtype. The rapid diagnosis of EI is essential to reduce the disease spread. Many rapid antigen detection (RAD) tests for diagnosing human influenza are available, but their ability to diagnose EI has not been systematically evaluated. The aim of this study was to compare the performance of 22 RAD tests in the diagnosis of EI. The 22 RAD tests were performed on fivefold serial dilutions of EI virus to determine their detection limits. The four most sensitive RAD tests (ImmunoAce Flu, BD Flu examan, Quick chaser Flu A, B and ESPLINE Influenza A&B-N) were further evaluated using nasopharyngeal samples collected from experimentally infected and naturally infected horses. The results were compared to those obtained using molecular tests. The detection limits of the 22 RAD tests varied hugely. Even the four RAD tests showing the best sensitivity were 125-fold less sensitive than the molecular techniques. The duration of virus detection in the experimentally infected horses was shorter using the RAD tests than using the molecular techniques. The RAD tests detected between 27% and 73% of real-time RT-PCR-positive samples from naturally infected horses. The study demonstrated the importance of choosing the right RAD tests as only three of 22 were fit for diagnosing EI. It was also indicated that even RAD tests with the highest sensitivity serve only as an adjunct to molecular tests because of the potential for false-negative results. © 2015 The Authors. Influenza and Other Respiratory Viruses Published by John Wiley & Sons Ltd.

  15. Reducing "Math Anxiety" in College Algebra Courses Including Comparisons with Elementary Statistics Courses.

    ERIC Educational Resources Information Center

    Bankhead, Mike

    The high levels of anxiety, apprehension, and apathy of students in college algebra courses caused the instructor to create and test a variety of math teaching techniques designed to boost student confidence and enthusiasm in the subject. Overall, this proposal covers several different techniques, which have been evaluated by both students and the…

  16. Average discharge, perennial flow initiation, and channel initiation - small southern Appalachian basins

    Treesearch

    B. Lane Rivenbark; C. Rhett Jackson

    2004-01-01

    Regional average evapotranspiration estimates developed by water balance techniques are frequently used to estimate average discharge in ungaged strttams. However, the lower stream size range for the validity of these techniques has not been explored. Flow records were collected and evaluated for 16 small streams in the Southern Appalachians to test whether the...

  17. Use of Authentic-Speech Technique for Teaching Sound Recognition to EFL Students

    ERIC Educational Resources Information Center

    Sersen, William J.

    2011-01-01

    The main objective of this research was to test an authentic-speech technique for improving the sound-recognition skills of EFL (English as a foreign language) students at Roi-Et Rajabhat University. The secondary objective was to determine the correlation, if any, between students' self-evaluation of sound-recognition progress and the actual…

  18. Triaxial testing system for pressure core analysis using image processing technique

    NASA Astrophysics Data System (ADS)

    Yoneda, J.; Masui, A.; Tenma, N.; Nagao, J.

    2013-11-01

    In this study, a newly developed innovative triaxial testing system to investigate strength, deformation behavior, and/or permeability of gas hydrate bearing-sediments in deep sea is described. Transport of the pressure core from the storage chamber to the interior of the sealing sleeve of a triaxial cell without depressurization was achieved. An image processing technique was used to capture the motion and local deformation of a specimen in a transparent acrylic triaxial pressure cell and digital photographs were obtained at each strain level during the compression test. The material strength was successfully measured and the failure mode was evaluated under high confining and pore water pressures.

  19. Waveforms and Sonic Boom Perception and Response (WSPR): Low-Boom Community Response Program Pilot Test Design, Execution, and Analysis

    NASA Technical Reports Server (NTRS)

    Page, Juliet A.; Hodgdon, Kathleen K.; Krecker, Peg; Cowart, Robbie; Hobbs, Chris; Wilmer, Clif; Koening, Carrie; Holmes, Theresa; Gaugler, Trent; Shumway, Durland L.; hide

    2014-01-01

    The Waveforms and Sonic boom Perception and Response (WSPR) Program was designed to test and demonstrate the applicability and effectiveness of techniques to gather data relating human subjective response to multiple low-amplitude sonic booms. It was in essence a practice session for future wider scale testing on naive communities, using a purpose built low-boom demonstrator aircraft. The low-boom community response pilot experiment was conducted in California in November 2011. The WSPR team acquired sufficient data to assess and evaluate the effectiveness of the various physical and psychological data gathering techniques and analysis methods.

  20. Slow crack growth in spinel in water

    NASA Technical Reports Server (NTRS)

    Schwantes, S.; Elber, W.

    1983-01-01

    Magnesium aluminate spinel was tested in a water environment at room temperature to establish its slow crack-growth behavior. Ring specimens with artificial flaws on the outside surface were loaded hydraulically on the inside surface. The time to failure was measured. Various precracking techniques were evaluated and multiple precracks were used to minimize the scatter in the static fatigue tests. Statistical analysis techniques were developed to determine the strength and crack velocities for a single flaw. Slow crack-growth rupture was observed at stress intensities as low as 70 percent of K sub c. A strengthening effect was observed in specimens that had survived long-time static fatigue tests.

  1. Comparison of digital and conventional impression techniques: evaluation of patients' perception, treatment comfort, effectiveness and clinical outcomes.

    PubMed

    Yuzbasioglu, Emir; Kurt, Hanefi; Turunc, Rana; Bilir, Halenur

    2014-01-30

    The purpose of this study was to compare two impression techniques from the perspective of patient preferences and treatment comfort. Twenty-four (12 male, 12 female) subjects who had no previous experience with either conventional or digital impression participated in this study. Conventional impressions of maxillary and mandibular dental arches were taken with a polyether impression material (Impregum, 3 M ESPE), and bite registrations were made with polysiloxane bite registration material (Futar D, Kettenbach). Two weeks later, digital impressions and bite scans were performed using an intra-oral scanner (CEREC Omnicam, Sirona). Immediately after the impressions were made, the subjects' attitudes, preferences and perceptions towards impression techniques were evaluated using a standardized questionnaire. The perceived source of stress was evaluated using the State-Trait Anxiety Scale. Processing steps of the impression techniques (tray selection, working time etc.) were recorded in seconds. Statistical analyses were performed with the Wilcoxon Rank test, and p < 0.05 was considered significant. There were significant differences among the groups (p < 0.05) in terms of total working time and processing steps. Patients stated that digital impressions were more comfortable than conventional techniques. Digital impressions resulted in a more time-efficient technique than conventional impressions. Patients preferred the digital impression technique rather than conventional techniques.

  2. Development of a high capacity bubble domain memory element and related epitaxial garnet materials for application in spacecraft data recorders. Item 2: The optimization of material-device parameters for application in bubble domain memory elements for spacecraft data recorders

    NASA Technical Reports Server (NTRS)

    Besser, P. J.

    1976-01-01

    Bubble domain materials and devices are discussed. One of the materials development goals was a materials system suitable for operation of 16 micrometer period bubble domain devices at 150 kHz over the temperature range -10 C to +60 C. Several material compositions and hard bubble suppression techniques were characterized and the most promising candidates were evaluated in device structures. The technique of pulsed laser stroboscopic microscopy was used to characterize bubble dynamic properties and device performance at 150 kHz. Techniques for large area LPE film growth were developed as a separate task. Device studies included detector optimization, passive replicator design and test and on-chip bridge evaluation. As a technology demonstration an 8 chip memory cell was designed, tested and delivered. The memory elements used in the cell were 10 kilobit serial registers.

  3. Characterization of flaws in a tube bundle mock-up for reliability studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kupperman, D.S.; Bakhtiari, S.

    1997-02-01

    As part of an assessment of in-service inspection of steam generator tubes, the authors will assemble a steam generator mock-up for round robin studies and use as a test bed in evaluating emerging technologies. Progress is reported on the characterization of flaws that will be part of the mock-up. Eddy current and ultrasonic techniques are being evaluated as a means to characterize the flaws in the mock-up tubes before final assembly. Twenty Inconel 600 tubes with laboratory-grown cracks, typical of those to be used in the mock-up, were provided by Pacific Northwest National Laboratory for laboratory testing. After the tubesmore » were inspected with eddy current and ultrasonic techniques, they were destructively analyzed to establish the actual depths, lengths, and profiles of the cracks. The analysis of the results will allow the best techniques to be used for characterizing the flaws in the mock-up tubes.« less

  4. Hypervelocity Impact Test Facility: A gun for hire

    NASA Technical Reports Server (NTRS)

    Johnson, Calvin R.; Rose, M. F.; Hill, D. C.; Best, S.; Chaloupka, T.; Crawford, G.; Crumpler, M.; Stephens, B.

    1994-01-01

    An affordable technique has been developed to duplicate the types of impacts observed on spacecraft, including the Shuttle, by use of a certified Hypervelocity Impact Facility (HIF) which propels particulates using capacitor driven electric gun techniques. The fully operational facility provides a flux of particles in the 10-100 micron diameter range with a velocity distribution covering the space debris and interplanetary dust particle environment. HIF measurements of particle size, composition, impact angle and velocity distribution indicate that such parameters can be controlled in a specified, tailored test designed for or by the user. Unique diagnostics enable researchers to fully describe the impact for evaluating the 'targets' under full power or load. Users regularly evaluate space hardware, including solar cells, coatings, and materials, exposing selected portions of space-qualified items to a wide range of impact events and environmental conditions. Benefits include corroboration of data obtained from impact events, flight simulation of designs, accelerated aging of systems, and development of manufacturing techniques.

  5. The effect of the air-blowing step on the technique sensitivity of four different adhesive systems.

    PubMed

    Spreafico, Diego; Semeraro, Stefano; Mezzanzanica, Dario; Re, Dino; Gagliani, Massimo; Tanaka, Toru; Sano, Hidehiko; Sidhu, Sharanbir K

    2006-03-01

    To evaluate the technique sensitivity of four different adhesive systems using different air-blowing pressure. Four adhesive systems were employed: Clearfil SE Bond [SE] (Kuraray, Japan), G-Bond [GB] (GC Corporation, Japan), Adper Prompt L-Pop [LP] (3M ESPE, USA) and an experimental adhesive, SSB-200 [SSB] (Kuraray, Japan). Twenty-four extracted molars were used. After grinding the coronal enamel surface, the teeth were divided into two equal groups. The first group's teeth were randomly assigned for bonding with the different adhesives using gentle air-blowing (g). For the teeth of the second group, the four adhesive systems were applied using strong air-blowing (s). After storage overnight in 37 degrees C water, the bonded specimens were sectioned into sticks (1 mm x 1 mm wide), which were subjected to microtensile bond strength testing (microTBS) at a crosshead speed of 1 mm/min. The load at failure of each specimen was recorded and the data were analyzed by one-way ANOVA and Tukey HSD tests. The surfaces of the fractured specimens were observed using SEM to determine the failure mode. The results of the microTBS test showed that the highest bond strengths tended to be with SE for both gentle and strong air-blowing, and the significantly lowest for SSB with strong air streaming. Comparing the two techniques, significant differences were noted only for SSB-200 (P < 0.05). For each material, the SEM evaluation did not show distinct differences in the nature of the fractures between the two techniques, except for SSB-200. The adhesives tested are not technique sensitive, except SSB-200, with regards to the air-blowing step.

  6. Testing of printed circuit board solder joints by optical correlation

    NASA Technical Reports Server (NTRS)

    Espy, P. N.

    1975-01-01

    An optical correlation technique for the nondestructive evaluation of printed circuit board solder joints was evaluated. Reliable indications of induced stress levels in solder joint lead wires are achievable. Definite relations between the inherent strength of a solder joint, with its associated ability to survive stress, are demonstrable.

  7. PREDICTION OF POPULATION-LEVEL RESPONSE FROM MYSID TOXICITY TEST DATA USING POPULATION MODEL TECHNIQUES

    EPA Science Inventory

    Acute and chronic bioassay statistics are used to evaluate the toxicity and the risks of chemical stressors to mysid shrimp Americamysis bahia (formerly Mysidopsis bahia). These include LC50 values from acute tests, chronic values (the geometric mean of the no-obsderved-effect co...

  8. College and Adult Reading, VI; Sixth Yearbook.

    ERIC Educational Resources Information Center

    Wark, David L., Ed.

    This volume contains the sixteen papers presented to the 1968, 1969, and 1970 annual meetings of the North Central Reading Association. The papers are grouped into four sections: Programs and Centers, Materials and Techniques, Evaluation, and Professional Problems. Some of the topics concern tests and test-taking, attitudinal factors, descriptions…

  9. A Content Analysis of Multinationals' Web Communication Strategies: Cross-Cultural Research Framework and Pre-Testing.

    ERIC Educational Resources Information Center

    Okazaki, Shintaro; Alonso Rivas, Javier

    2002-01-01

    Discussion of research methodology for evaluating the degree of standardization in multinational corporations' online communication strategies across differing cultures focuses on a research framework for cross-cultural comparison of corporate Web pages, applying traditional advertising content study techniques. Describes pre-tests that examined…

  10. Preliminary shuttle structural dynamics modeling design study

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The design and development of a structural dynamics model of the space shuttle are discussed. The model provides for early study of structural dynamics problems, permits evaluation of the accuracy of the structural and hydroelastic analysis methods used on test vehicles, and provides for efficiently evaluating potential cost savings in structural dynamic testing techniques. The discussion is developed around the modes in which major input forces and responses occur and the significant structural details in these modes.

  11. Real-time in-flight engine performance and health monitoring techniques for flight research application

    NASA Technical Reports Server (NTRS)

    Ray, Ronald J.; Hicks, John W.; Wichman, Keith D.

    1991-01-01

    Procedures for real time evaluation of the inflight health and performance of gas turbine engines and related systems were developed to enhance flight test safety and productivity. These techniques include the monitoring of the engine, the engine control system, thrust vectoring control system health, and the detection of engine stalls. Real time performance techniques were developed for the determination and display of inflight thrust and for aeroperformance drag polars. These new methods were successfully shown on various research aircraft at NASA-Dryden. The capability of NASA's Western Aeronautical Test Range and the advanced data acquisition systems were key factors for implementation and real time display of these methods.

  12. Global surface temperature/heat transfer measurements using infrared imaging

    NASA Technical Reports Server (NTRS)

    Daryabeigi, Kamran

    1992-01-01

    A series of studies were conducted to evaluate the use of scanning radiometric infrared imaging systems for providing global surface temperature/heat transfer measurements in support of hypersonic wind tunnel testing. The in situ precision of the technique with narrow temperature span setting over the temperature range of 20 to 200 C was investigated. The precision of the technique over wider temperature span settings was also determined. The accuracy of technique for providing aerodynamic heating rates was investigated by performing measurements on a 10.2-centimeter hemisphere model in the Langley 31-inch Mach 10 tunnel, and comparing the results with theoretical predictions. Data from tests conducted on a generic orbiter model in this tunnel are also presented.

  13. Evaluation of Erosion Potential of Estuarine Sediments in NY/NJ Harbor (Impact of In-Situ Stabilization on the Remediation of Soft Sediments - A preamble to Erosion Testing and Evaluation)

    DOT National Transportation Integrated Search

    2011-09-01

    The primary objective of the project are to perform a review of existing in-situ techniques of sediment erosion potential evaluation in contaminated "superfund" sites in the United States and those from Europe and Japan and the applicability of soft ...

  14. Repetition as an Oral Language Assessment Technique. Final Report.

    ERIC Educational Resources Information Center

    Natalicio, Diana S.; Williams, Frederick

    The aim of this study is to assess the degree to which sentence imitations of Negro and Mexican-American children (grades K-2) could be used as a basis for language evaluation. Tapes of 10 Negro and 10 Mexican-American children who had responded to a set of commercially available test materials were evaluated by panels of experts. Evaluations for…

  15. Detection of Dirofilaria immitis and other arthropod-borne filarioids by an HRM real-time qPCR, blood-concentrating techniques and a serological assay in dogs from Costa Rica.

    PubMed

    Rojas, Alicia; Rojas, Diana; Montenegro, Víctor M; Baneth, Gad

    2015-03-23

    Canine filarioids are important nematodes transmitted to dogs by arthropods. Diagnosis of canine filariosis is accomplished by the microscopic identification of microfilariae, serology or PCR for filarial-DNA. The aim of this study was to evaluate a molecular assay for the detection of canine filariae in dog blood, to compare its performance to other diagnostic techniques, and to determine the relationship between microfilarial concentration and infection with other vector-borne pathogens. Blood samples from 146 dogs from Costa Rica were subjected to the detection of canine filarioids by four different methods: the microhematocrit tube test (MCT), Knott's modified test, serology and a high resolution melt and quantitative real-time PCR (HRM-qPCR). Co-infection with other vector-borne pathogens was also evaluated. Fifteen percent of the dogs were positive to Dirofilaria immitis by at least one of the methods. The HRM-qPCR produced distinctive melting plots for the different filarial worms and revealed that 11.6% of dogs were infected with Acanthocheilonema reconditum. The latter assay had a limit of detection of 2.4x10⁻⁴ mf/μl and detected infections with lower microfilarial concentrations in comparison to the microscopic techniques and the serological assay. The MCT and Knott's test only detected dogs with D. immitis microfilaremias above 0.7 mf/μl. Nevertheless, there was a strong correlation between the microfilarial concentration obtained by the Knott's modified test and the HRM-qPCR (r = 0.906, p < 0.0001). Interestingly, one dog was found infected with Cercopithifilaria bainae infection. Moreover, no association was found between microfilaremia and co-infection and there was no significant difference in microfilarial concentration between dogs infected only with D. immitis and dogs co-infected with Ehrlichia canis, Anaplasma platys or Babesia vogeli. This is the first report of A. reconditum and C. bainae in Costa Rica and Central America. Among the evaluated diagnostic techniques, the HRM-qPCR showed the most sensitive and reliable performance in the detection of blood filaroids in comparison to the Knott's modified test, the MCT test and a serological assay.

  16. Shearography for Non-destructive Inspection with applications to BAT Mask Tile Adhesive Bonding and Specular Surface Honeycomb Panels

    NASA Technical Reports Server (NTRS)

    Lysak, Daniel B.

    2003-01-01

    The applicability of shearography techniques for non-destructive evaluation in two unique application areas is examined. In the first application, shearography is used to evaluate the quality of adhesive bonds holding lead tiles to the B.4T gamma ray mask for the NASA Swift program. Using a vibration excitation, the more poorly bonded tiles are readily identifiable in the shearography image. A quantitative analysis is presented that compares the shearography results with a destructive pull test measuring the force at bond failure. The second application is to evaluate the bonding between the skin and core of a honeycomb structure with a specular (mirror-like) surface. In standard shearography techniques, the object under test must have a diffuse surface to generate the speckle patterns in laser light, which are then sheared. A novel configuration using the specular surface as a mirror to image speckles from a diffuser is presented, opening up the use of shearography to a new class of objects that could not have been examined with the traditional approach. This new technique readily identifies large scale bond failures in the panel, demonstrating the validity of this approach.

  17. Evaluation of SLAR and thematic mapper MSS data for forest cover mapping using computer-aided analysis techniques

    NASA Technical Reports Server (NTRS)

    Hoffer, R. M. (Principal Investigator)

    1980-01-01

    The column normalizing technique was used to adjust the data for variations in the amplitude of the signal due to look angle effects with respect to solar zenith angle along the scan lines (i.e., across columns). Evaluation of the data set containing the geometric and radiometric adjustments, indicates that the data set should be satisfactory for further processing and analysis. Software was developed for degrading the spatial resolution of the aircraft data to produce a total of four data sets for further analysis. The quality of LANDSAT 2 CCT data for the test site is good for channels four, five, and six. Channel seven was not present on the tape. The data received were reformatted and analysis of the test site area was initiated.

  18. Ultrasonic linear array validation via concrete test blocks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoegh, Kyle, E-mail: hoeg0021@umn.edu; Khazanovich, Lev, E-mail: hoeg0021@umn.edu; Ferraro, Chris

    2015-03-31

    Oak Ridge National Laboratory (ORNL) comparatively evaluated the ability of a number of NDE techniques to generate an image of the volume of 6.5′ X 5.0′ X 10″ concrete specimens fabricated at the Florida Department of Transportation (FDOT) NDE Validation Facility in Gainesville, Florida. These test blocks were fabricated to test the ability of various NDE methods to characterize various placements and sizes of rebar as well as simulated cracking and non-consolidation flaws. The first version of the ultrasonic linear array device, MIRA [version 1], was one of 7 different NDE equipment used to characterize the specimens. This paper dealsmore » with the ability of this equipment to determine subsurface characterizations such as reinforcing steel relative size, concrete thickness, irregularities, and inclusions using Kirchhoff-based migration techniques. The ability of individual synthetic aperture focusing technique (SAFT) B-scan cross sections resulting from self-contained scans are compared with various processing, analysis, and interpretation methods using the various features fabricated in the specimens for validation. The performance is detailed, especially with respect to the limitations and implications for evaluation of a thicker, more heavily reinforced concrete structures.« less

  19. Nondestructive evaluation of plasma-sprayed thermal barrier coatings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andrews, D.J.; Taylor, J.A.T.

    Acoustic emission has been used as a nondestructive evaluation technique to examine the thermal shock response of thermal barrier coatings. In this study, samples of partially stabilized zirconia powder were sprayed and acoustic emission (AE) data were taken in a series of thermal shock tests in an effort to correlate AE with a given failure mechanism. Microstructural evidence was examined using parallel beam x-ray diffraction and optical microscopy. The AE data are discussed in terms of cumulative amplitude distributions and the use of this technique to characterize fracture events.

  20. The DAST-1 remotely piloted research vehicle development and initial flight testing

    NASA Technical Reports Server (NTRS)

    Kotsabasis, A.

    1981-01-01

    The development and initial flight testing of the DAST (drones for aerodynamic and structural testing) remotely piloted research vehicle, fitted with the first aeroelastic research wing ARW-I are presented. The ARW-I is a swept supercritical wing, designed to exhibit flutter within the vehicle's flight envelope. An active flutter suppression system (FSS) designed to increase the ARW-I flutter boundary speed by 20 percent is described. The development of the FSS was based on prediction techniques of structural and unsteady aerodynamic characteristics. A description of the supporting ground facilities and aircraft systems involved in the remotely piloted research vehicle (RPRV) flight test technique is given. The design, specification, and testing of the remotely augmented vehicle system are presented. A summary of the preflight and flight test procedures associated with the RPRV operation is given. An evaluation of the blue streak test flight and the first and second ARW-I test flights is presented.

  1. An Evaluation of Seismic Reflection Studies in the Yucca Mountain Area, Nevada Test Site

    USGS Publications Warehouse

    McGovern, Thomas F.; Introduction by Pankratz, L. W.; Ackermann, H.D.

    1983-01-01

    As part of a total geophysical evaluation of Yucca Mountain for use as a Nuclear Waste Repository the seismic reflection technique has been applied. This study has been conducted to analyze the historical and technical efforts which have been used by three geophysical contractors employing a wide variety of techniques ranging from the most simple to very elaborate 3-D surveys. In each case elaborate noise studies were conducted, and based upon their evaluation parameters were chosen for multifold CDP recording. In every case, the signal-to-noise ratio was such that no reflections were discernable. Since the reflections cannot be separated from the noise even using very elaborate noise suppression techniques and up to 384 fold multiplicity it is apparent that in this volcanic terrain reflection surveys, can not work.

  2. Quiet engine program: Turbine noise suppression. -Volume 1: General treatment evaluation and measurement techniques

    NASA Technical Reports Server (NTRS)

    Clemons, A.; Hehmann, H.; Radecki, K.

    1973-01-01

    Acoustic treatment was developed for jet engine turbine noise suppression. Acoustic impedance and duct transmission loss measurements were made for various suppression systems. An environmental compatibility study on several material types having suppression characteristics is presented. Two sets of engine hardware were designed and are described along with engine test results which include probe, farfield, near field, and acoustic directional array data. Comparisons of the expected and the measured suppression levels are given as well as a discussion of test results and design techniques.

  3. Feasibility Study for Implementing Magnetic Suspension in the Glenn Research Center 225 cm2 Supersonic Wind Tunnel for Testing the Dynamic Stability of Blunt Bodies

    NASA Technical Reports Server (NTRS)

    Sevier, Abigail; Davis, David O.; Schoenenberger, Mark; Barnhart, Paul

    2016-01-01

    The implementation of a magnetic suspension system in the NASA Glenn Research Center (GRC) 225 cm2 Supersonic Wind Tunnel would be a powerful test technique that could accurately determine the dynamic stability of blunt body entry vehicles with no sting interference. This paper explores initial design challenges to be evaluated before implementation, including defining the lowest possible operating dynamic pressure and corresponding model size, developing a compatible video analysis technique, and incorporating a retractable initial support sting.

  4. Analytical study of acousto/optical holography-interfacing methods for acoustical and optical holography NDT research

    NASA Technical Reports Server (NTRS)

    El-Sum, H. M. A.

    1976-01-01

    The international status of the art of acousto optical imaging techniques adaptable to nondestructive testing and, interfacing methods for acoustical and optical holography in nondestructive testing research are studied. Evaluation of 20 different techniques encompassed investigation of varieties of detectors and detection schemes, all of which are described and summarized. Related investigation is reported in an Appendix. Important remarks on image quality, factors to be considered in designing a particular system, and conclusions and recommendations are presented. Three bibliographies are included.

  5. Reservoir engineering applications for development and exploitation of geothermal fields in the Philippines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vasquez, N.C.; Sarmiento, Z.F.

    1986-07-01

    After a geothermal well is completed, several tests and downhole measurements are conducted to help evaluate the subsurface fluid and reservoir properties intersected. From these tests, a conceptual model of the well can be developed by integrating data from the various parts of the field. This paper presents the completion techniques applied in geothermal wells, as well as the role of reservoir engineering science in delineating a field for development. Monitoring techniques and other reservoir engineering aspects of a field under exploitation are also discussed, with examples from the Philippines.

  6. AGARD Flight Test Instrumentation Series. Volume 1, Issue 2. Basic Principles of Flight Test Instrumentation Engineering (Introduction Generale aux Principles de Base de l’Instrumentation des Essais en Vol)

    DTIC Science & Technology

    1994-03-01

    evaluation of its anticipated value. If the program can be accomplished using conventional techniques , this should be seriously considered. Development or...the direct frequency generating principles such as, pulse tachos, turbine flowmeters, and encoders, also Doppler and laser techniques used for...CERAMIC BLOCK Figure 5.3. The basic concepts of the laser ring gyro (LRG). The principle depends upon the guidance of two beams of laser light around an

  7. Benchmark Testing of a New 56Fe Evaluation for Criticality Safety Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leal, Luiz C; Ivanov, E.

    2015-01-01

    The SAMMY code was used to evaluate resonance parameters of the 56Fe cross section in the resolved resonance energy range of 0–2 MeV using transmission data, capture, elastic, inelastic, and double differential elastic cross sections. The resonance analysis was performed with the code SAMMY that fits R-matrix resonance parameters using the generalized least-squares technique (Bayes’ theory). The evaluation yielded a set of resonance parameters that reproduced the experimental data very well, along with a resonance parameter covariance matrix for data uncertainty calculations. Benchmark tests were conducted to assess the evaluation performance in benchmark calculations.

  8. Using Innovative Technologies for Manufacturing Rocket Engine Hardware

    NASA Technical Reports Server (NTRS)

    Betts, E. M.; Eddleman, D. E.; Reynolds, D. C.; Hardin, N. A.

    2011-01-01

    Many of the manufacturing techniques that are currently used for rocket engine component production are traditional methods that have been proven through years of experience and historical precedence. As the United States enters into the next space age where new launch vehicles are being designed and propulsion systems are being improved upon, it is sometimes necessary to adopt innovative techniques for manufacturing hardware. With a heavy emphasis on cost reduction and improvements in manufacturing time, rapid manufacturing techniques such as Direct Metal Laser Sintering (DMLS) are being adopted and evaluated for their use on NASA s Space Launch System (SLS) upper stage engine, J-2X, with hopes of employing this technology on a wide variety of future projects. DMLS has the potential to significantly reduce the processing time and cost of engine hardware, while achieving desirable material properties by using a layered powder metal manufacturing process in order to produce complex part geometries. Marshall Space Flight Center (MSFC) has recently hot-fire tested a J-2X gas generator (GG) discharge duct that was manufactured using DMLS. The duct was inspected and proof tested prior to the hot-fire test. Using a workhorse gas generator (WHGG) test fixture at MSFC's East Test Area, the duct was subjected to extreme J-2X hot gas environments during 7 tests for a total of 537 seconds of hot-fire time. The duct underwent extensive post-test evaluation and showed no signs of degradation. DMLS manufacturing has proven to be a viable option for manufacturing rocket engine hardware, and further development and use of this manufacturing method is recommended.

  9. Applications of Advanced, Waveform Based AE Techniques for Testing Composite Materials

    NASA Technical Reports Server (NTRS)

    Prosser, William H.

    1996-01-01

    Advanced, waveform based acoustic emission (AE) techniques have been previously used to evaluate damage progression in laboratory tests of composite coupons. In these tests, broad band, high fidelity acoustic sensors were used to detect signals which were then digitized and stored for analysis. Analysis techniques were based on plate mode wave propagation characteristics. This approach, more recently referred to as Modal AE, provides an enhanced capability to discriminate and eliminate noise signals from those generated by damage mechanisms. This technique also allows much more precise source location than conventional, threshold crossing arrival time determination techniques. To apply Modal AE concepts to the interpretation of AE on larger composite structures, the effects of wave propagation over larger distances and through structural complexities must be well characterized and understood. In this research, measurements were made of the attenuation of the extensional and flexural plate mode components of broad band simulated AE signals in large composite panels. As these materials have applications in a cryogenic environment, the effects of cryogenic insulation on the attenuation of plate mode AE signals were also documented.

  10. Multi-frame image processing with panning cameras and moving subjects

    NASA Astrophysics Data System (ADS)

    Paolini, Aaron; Humphrey, John; Curt, Petersen; Kelmelis, Eric

    2014-06-01

    Imaging scenarios commonly involve erratic, unpredictable camera behavior or subjects that are prone to movement, complicating multi-frame image processing techniques. To address these issues, we developed three techniques that can be applied to multi-frame image processing algorithms in order to mitigate the adverse effects observed when cameras are panning or subjects within the scene are moving. We provide a detailed overview of the techniques and discuss the applicability of each to various movement types. In addition to this, we evaluated algorithm efficacy with demonstrated benefits using field test video, which has been processed using our commercially available surveillance product. Our results show that algorithm efficacy is significantly improved in common scenarios, expanding our software's operational scope. Our methods introduce little computational burden, enabling their use in real-time and low-power solutions, and are appropriate for long observation periods. Our test cases focus on imaging through turbulence, a common use case for multi-frame techniques. We present results of a field study designed to test the efficacy of these techniques under expanded use cases.

  11. Nondestructive analysis and development

    NASA Technical Reports Server (NTRS)

    Moslehy, Faissal A.

    1993-01-01

    This final report summarizes the achievements of project #4 of the NASA/UCF Cooperative Agreement from January 1990 to December 1992. The objectives of this project are to review NASA's NDE program at Kennedy Space Center (KSC) and recommend means for enhancing the present testing capabilities through the use of improved or new technologies. During the period of the project, extensive development of a reliable nondestructive, non-contact vibration technique to determine and quantify the bond condition of the thermal protection system (TPS) tiles of the Space Shuttle Orbiter was undertaken. Experimental modal analysis (EMA) is used as a non-destructive technique for the evaluation of Space Shuttle thermal protection system (TPS) tile bond integrity. Finite element (FE) models for tile systems were developed and were used to generate their vibration characteristics (i.e. natural frequencies and mode shapes). Various TPS tile assembly configurations as well as different bond conditions were analyzed. Results of finite element analyses demonstrated a drop in natural frequencies and a change in mode shapes which correlate with both size and location of disbond. Results of experimental testing of tile panels correlated with FE results and demonstrated the feasibility of EMA as a viable technique for tile bond verification. Finally, testing performed on the Space Shuttle Columbia using a laser doppler velocimeter demonstrated the application of EMA, when combined with FE modeling, as a non-contact, non-destructive bond evaluation technique.

  12. Effectiveness of Video Demonstration over Conventional Methods in Teaching Osteology in Anatomy.

    PubMed

    Viswasom, Angela A; Jobby, Abraham

    2017-02-01

    Technology and its applications are the most happening things in the world. So, is it in the field of medical education. This study was an evaluation of whether the conventional methods can compete with the test of technology. A comparative study of traditional method of teaching osteology in human anatomy with an innovative visual aided method. The study was conducted on 94 students admitted to MBBS 2014 to 2015 batch of Travancore Medical College. The students were divided into two academically validated groups. They were taught using conventional and video demonstrational techniques in a systematic manner. Post evaluation tests were conducted. Analysis of the mark pattern revealed that the group taught using traditional method scored better when compared to the visual aided method. Feedback analysis showed that, the students were able to identify bony features better with clear visualisation and three dimensional view when taught using the video demonstration method. The students identified visual aided method as the more interesting one for learning which helped them in applying the knowledge gained. In most of the questions asked, the two methods of teaching were found to be comparable on the same scale. As the study ends, we discover that, no new technique can be substituted for time tested techniques of teaching and learning. The ideal method would be incorporating newer multimedia techniques into traditional classes.

  13. Evaluating the use of laser radiation in cleaning of copper embroidery threads on archaeological Egyptian textiles

    NASA Astrophysics Data System (ADS)

    Abdel-Kareem, Omar; Harith, M. A.

    2008-07-01

    Cleaning of copper embroidery threads on archaeological textiles is still a complicated conservation process, as most textile conservators believe that the advantages of using traditional cleaning techniques are less than their disadvantages. In this study, the uses of laser cleaning method and two modified recipes of wet cleaning methods were evaluated for cleaning of the corroded archaeological Egyptian copper embroidery threads on an archaeological Egyptian textile fabric. Some corroded copper thread samples were cleaned using modified recipes of wet cleaning method; other corroded copper thread samples were cleaned with Q-switched Nd:YAG laser radiation of wavelength 532 nm. All tested metal thread samples before and after cleaning were investigated using a light microscope and a scanning electron microscope with an energy dispersive X-ray analysis unit. Also the laser-induced breakdown spectroscopy (LIBS) technique was used for the elemental analysis of laser-cleaned samples to follow up the laser cleaning procedure. The results show that laser cleaning is the most effective method among all tested methods in the cleaning of corroded copper threads. It can be used safely in removing the corrosion products without any damage to both metal strips and fibrous core. The tested laser cleaning technique has solved the problems caused by other traditional cleaning techniques that are commonly used in the cleaning of metal threads on museum textiles.

  14. 40 CFR 158.2110 - Microbial pesticides data requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...: genetic engineering techniques used; the identity of the inserted or deleted gene segment (base sequence... evaluate genetic stability and exchange; and selected Tier II environmental expression and toxicology tests. ...

  15. 40 CFR 158.2110 - Microbial pesticides data requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...: genetic engineering techniques used; the identity of the inserted or deleted gene segment (base sequence... evaluate genetic stability and exchange; and selected Tier II environmental expression and toxicology tests. ...

  16. 40 CFR 158.2110 - Microbial pesticides data requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...: genetic engineering techniques used; the identity of the inserted or deleted gene segment (base sequence... evaluate genetic stability and exchange; and selected Tier II environmental expression and toxicology tests. ...

  17. 40 CFR 158.2110 - Microbial pesticides data requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...: genetic engineering techniques used; the identity of the inserted or deleted gene segment (base sequence... evaluate genetic stability and exchange; and selected Tier II environmental expression and toxicology tests. ...

  18. Experiments with ceramic coatings

    NASA Technical Reports Server (NTRS)

    Lynn, E. K.; Rollins, C. T.

    1968-01-01

    Report describes the procedures and techniques used in the application of a ceramic coating and the evaluation of test parts through observation of the cracks that occur in this coating due to loading.

  19. Instructional Practices: A Practical Final for Speech Fundamentals

    ERIC Educational Resources Information Center

    Miles, Paul L.

    1977-01-01

    Explores the testing technique of practical extemporaneous speech finals for students enrolled in the fundamentals course and emphasizes the objectives, procedures and evaluation criteria for such an approach. (MH)

  20. LOX/Hydrocarbon Combustion Instability Investigation

    NASA Technical Reports Server (NTRS)

    Jensen, R. J.; Dodson, H. C.; Claflin, S. E.

    1989-01-01

    The LOX/Hydrocarbon Combustion Instability Investigation Program was structured to determine if the use of light hydrocarbon combustion fuels with liquid oxygen (LOX) produces combustion performance and stability behavior similar to the LOX/hydrogen propellant combination. In particular methane was investigated to determine if that fuel can be rated for combustion instability using the same techniques as previously used for LOX/hydrogen. These techniques included fuel temperature ramping and stability bomb tests. The hot fire program probed the combustion behavior of methane from ambient to subambient temperatures. Very interesting results were obtained from this program that have potential importance to future LOX/methane development programs. A very thorough and carefully reasoned documentation of the experimental data obtained is contained. The hot fire test logic and the associated tests are discussed. Subscale performance and stability rating testing was accomplished using 40,000 lb. thrust class hardware. Stability rating tests used both bombs and fuel temperature ramping techniques. The test program was successful in generating data for the evaluation of the methane stability characteristics relative to hydrogen and to anchor stability models. Data correlations, performance analysis, stability analyses, and key stability margin enhancement parameters are discussed.

  1. Evaluation of a technique for color correction in restoring anterior teeth.

    PubMed

    Rauber, Gabrielle Branco; Bernardon, Jussara Karina; Vieira, Luiz Clovis Cardoso; Baratieri, Luiz Narciso

    2017-09-01

    This study aimed to evaluate the ability of the proposed technique in producing restorations that exhibit mimesis with tooth structure and to define a restorative clinical protocol. For this study a typodont was used. The right upper central incisor with Class IV lesion was restored with the layering technique (reference tooth, RT). For the left upper central incisor with Class IV lesion, six teeth were restored monochromatically (test teeth, TT), using DA3.5 (n = 3) and DA4 (n = 3) composite resins-resulting in six unsatisfactory color restorations. TT were divided into six groups depending on the color of unsatisfactory restoration and preparation depth. First, a preparation was realized on the labial surface with 0.5 mm, 0.7 mm or 1.0 mm of depth. A second preparation was then performed to reproduce the dentinal mamelons. Next, adhesive procedures were performed and the teeth restored. Opaque halo, opalescent halo and vestibular enamel were then reproduced by the addition of different composite resins. The RT and TT were photographed side by side in typodont to obtain six photographic prints. The photographs of the groups were subjected to visual evaluation by 120 volunteers via a questionnaire. Data were analyzed by the prevalence of answers, and Chi-square test was used to investigate the association between variables at .05 significance. Furthermore, ΔE of groups was evaluated in comparison RT. The results demonstrated that the moderate intensity restorations (DA3.5) with depths of 0.5 mm and 0.7 mm had the highest prevalence of acceptance. For severe intensity restorations (DA4), the preparation depth of 1.0 mm obtained better acceptance. The technique was able to modify the final color of Class IV restorations, producing satisfactory color restorations. This technique can be used for color correction in cases of Class IV restorations, in situations where there is no time for immediate layered restoration, and as a restorative technique. © 2017 Wiley Periodicals, Inc.

  2. Signal Detection Techniques for Diagnostic Monitoring of Space Shuttle Main Engine Turbomachinery

    NASA Technical Reports Server (NTRS)

    Coffin, Thomas; Jong, Jen-Yi

    1986-01-01

    An investigation to develop, implement, and evaluate signal analysis techniques for the detection and classification of incipient mechanical failures in turbomachinery is reviewed. A brief description of the Space Shuttle Main Engine (SSME) test/measurement program is presented. Signal analysis techniques available to describe dynamic measurement characteristics are reviewed. Time domain and spectral methods are described, and statistical classification in terms of moments is discussed. Several of these waveform analysis techniques have been implemented on a computer and applied to dynamc signals. A laboratory evaluation of the methods with respect to signal detection capability is described. A unique coherence function (the hyper-coherence) was developed through the course of this investigation, which appears promising as a diagnostic tool. This technique and several other non-linear methods of signal analysis are presented and illustrated by application. Software for application of these techniques has been installed on the signal processing system at the NASA/MSFC Systems Dynamics Laboratory.

  3. Biomechanical evaluation of native acromioclavicular joint ligaments and two reconstruction techniques in the presence of the sternoclavicular joint: A cadaver study.

    PubMed

    Masionis, Povilas; Šatkauskas, Igoris; Mikelevičius, Vytautas; Ryliškis, Sigitas; Bučinskas, Vytautas; Griškevičius, Julius; Martin Oliva, Xavier; Monzó Planella, Mariano; Porvaneckas, Narūnas; Uvarovas, Valentinas

    2017-01-01

    Where is over 100 reconstruction techniques described for acromioclavicular (AC) joint reconstruction. Although, it is not clear whether the presence of the sternoclavicular (SC) joint influences the biomechanical properties of native AC ligaments and reconstruction techniques. The purpose of the present study was to investigate the biomechanical properties of native AC joint ligaments and two reconstruction techniques in cadavers with the SC joint still present. We tested eight fresh-frozen cadaver hemithoraces for superior translation (70 N load) and translation increment after 1000 cycles (loading from 20 to 70 N) in a controlled laboratory study. There were three testing groups created: native ligaments, the single coracoclavicular loop (SCL) technique, and the two coracoclavicular loops (TCL) technique. Superior translation was measured after static loading. Translation increment was calculated as the difference between superior translation after cyclic and static loading. Native AC ligaments showed significantly lower translation than the SCL ( p = 0.023) and TCL ( p = 0.046) groups. The SCL had a significantly lower translation increment than native AC ligaments ( p = 0.028). There was no significant difference between reconstruction techniques in terms of translation ( p = 0.865) and translation increment ( p = 0.113). Native AC joint ligaments had better static properties than both reconstruction techniques and worse dynamic biomechanical properties than the SCL technique. The SCL technique appeared to be more secure than the TCL technique. The presence of the SC joint did not have an observable influence on test results.

  4. Study Of Nondestructive Techniques For Testing Composites

    NASA Technical Reports Server (NTRS)

    Roth, D.; Kautz, H.; Draper, S.; Bansal, N.; Bowles, K.; Bashyam, M.; Bishop, C.

    1995-01-01

    Study evaluates some nondestructive methods for characterizing ceramic-, metal-, and polymer-matrix composite materials. Results demonstrated utility of two ultrasonic methods for obtaining quantitative data on microstructural anomalies in composite materials.

  5. Radiation Hardening by Software Techniques on FPGAs: Flight Experiment Evaluation and Results

    NASA Technical Reports Server (NTRS)

    Schmidt, Andrew G.; Flatley, Thomas

    2017-01-01

    We present our work on implementing Radiation Hardening by Software (RHBSW) techniques on the Xilinx Virtex5 FPGAs PowerPC 440 processors on the SpaceCube 2.0 platform. The techniques have been matured and tested through simulation modeling, fault emulation, laser fault injection and now in a flight experiment, as part of the Space Test Program- Houston 4-ISS SpaceCube Experiment 2.0 (STP-H4-ISE 2.0). This work leverages concepts such as heartbeat monitoring, control flow assertions, and checkpointing, commonly used in the High Performance Computing industry, and adapts them for use in remote sensing embedded systems. These techniques are extremely low overhead (typically <1.3%), enabling a 3.3x gain in processing performance as compared to the equivalent traditionally radiation hardened processor. The recently concluded STP-H4 flight experiment was an opportunity to upgrade the RHBSW techniques for the Virtex5 FPGA and demonstrate them on-board the ISS to achieve TRL 7. This work details the implementation of the RHBSW techniques, that were previously developed for the Virtex4-based SpaceCube 1.0 platform, on the Virtex5-based SpaceCube 2.0 flight platform. The evaluation spans the development and integration with flight software, remotely uploading the new experiment to the ISS SpaceCube 2.0 platform, and conducting the experiment continuously for 16 days before the platform was decommissioned. The experiment was conducted on two PowerPCs embedded within the Virtex5 FPGA devices and the experiment collected 19,400 checkpoints, processed 253,482 status messages, and incurred 0 faults. These results are highly encouraging and future work is looking into longer duration testing as part of the STP-H5 flight experiment.

  6. Implementation of an Outer Can Welding System for Savannah River Site FB-Line

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howard, S.R.

    2003-03-27

    This paper details three phases of testing to confirm use of a Gas Tungsten Arc (GTA) system for closure welding the 3013 outer container used for stabilization/storage of plutonium metals and oxides. The outer container/lid closure joint was originally designed for laser welding, but for this application, the gas tungsten arc (GTA) welding process has been adapted. The testing progressed in three phases: (1) system checkout to evaluate system components for operational readiness, (2) troubleshooting to evaluate high weld failure rates and develop corrective techniques, and (3) pre-installation acceptance testing.

  7. Optical Measurement Techniques for Rocket Engine Testing and Component Applications: Digital Image Correlation and Dynamic Photogrammetry

    NASA Technical Reports Server (NTRS)

    Gradl, Paul

    2016-01-01

    NASA Marshall Space Flight Center (MSFC) has been advancing dynamic optical measurement systems, primarily Digital Image Correlation, for extreme environment rocket engine test applications. The Digital Image Correlation (DIC) technology is used to track local and full field deformations, displacement vectors and local and global strain measurements. This technology has been evaluated at MSFC through lab testing to full scale hotfire engine testing of the J-2X Upper Stage engine at Stennis Space Center. It has been shown to provide reliable measurement data and has replaced many traditional measurement techniques for NASA applications. NASA and AMRDEC have recently signed agreements for NASA to train and transition the technology to applications for missile and helicopter testing. This presentation will provide an overview and progression of the technology, various testing applications at NASA MSFC, overview of Army-NASA test collaborations and application lessons learned about Digital Image Correlation.

  8. Disequilibrium after Traumatic Brain Injury: Vestibular Mechanisms

    DTIC Science & Technology

    2012-09-01

    potentially modifiable factors. 0078 Chiropractic Sacro Occipital Technique (SOT) and Cranial Treatment Model for Traumatic Brain Injury Along with...model incorporating laboratory testing to evaluate neurotrans- mitter balance and chiropractic cranial care for the treatment of a patient with traumatic...Approach She has been under care for three years, which consisted of chiropractic sacro occipital technique (SOT) and cranial treat- ment. Within the

  9. Estimating bridge stiffness using a forced-vibration technique for timber bridge health monitoring

    Treesearch

    James P. Wacker; Xiping Wang; Brian Brashaw; Robert J. Ross

    2006-01-01

    This paper describes an effort to refine a global dynamic testing technique for evaluating the overall stiffness of timber bridge superstructures. A forced vibration method was used to measure the frequency response of several simple-span, sawn timber beam (with plank deck) bridges located in St. Louis County, Minnesota. Static load deflections were also measured to...

  10. Perfect Mirror Design Technology

    DTIC Science & Technology

    1999-02-01

    with Prof. Mario Molina, recipient of the 1995 Nobel Prize in Chemistry. The partnership, along with Aerodyne Research Inc., looked at how sulfur...Corporation is developing standards for nondestructive evaluation ( NDE ) techniques for industry use. Use of the new standards will result in improved...novel testing methodology that dramatically improves the accuracy of NDE techniques used to detect flaws. Basic Research Five years ago, the main

  11. Current issues and future perspectives of gastric cancer screening

    PubMed Central

    Hamashima, Chisato

    2014-01-01

    Gastric cancer remains the second leading cause of cancer death worldwide. About half of the incidence of gastric cancer is observed in East Asian countries, which show a higher mortality than other countries. The effectiveness of 3 new gastric cancer screening techniques, namely, upper gastrointestinal endoscopy, serological testing, and “screen and treat” method were extensively reviewed. Moreover, the phases of development for cancer screening were analyzed on the basis of the biomarker development road map. Several observational studies have reported the effectiveness of endoscopic screening in reducing mortality from gastric cancer. On the other hand, serologic testing has mainly been used for targeting the high-risk group for gastric cancer. To date, the effectiveness of new techniques for gastric cancer screening has remained limited. However, endoscopic screening is presently in the last trial phase of development before their introduction to population-based screening. To effectively introduce new techniques for gastric cancer screening in a community, incidence and mortality reduction from gastric cancer must be initially and thoroughly evaluated by conducting reliable studies. In addition to effectiveness evaluation, the balance of benefits and harms must be carefully assessed before introducing these new techniques for population-based screening. PMID:25320514

  12. Support Vector Machine Based on Adaptive Acceleration Particle Swarm Optimization

    PubMed Central

    Abdulameer, Mohammed Hasan; Othman, Zulaiha Ali

    2014-01-01

    Existing face recognition methods utilize particle swarm optimizer (PSO) and opposition based particle swarm optimizer (OPSO) to optimize the parameters of SVM. However, the utilization of random values in the velocity calculation decreases the performance of these techniques; that is, during the velocity computation, we normally use random values for the acceleration coefficients and this creates randomness in the solution. To address this problem, an adaptive acceleration particle swarm optimization (AAPSO) technique is proposed. To evaluate our proposed method, we employ both face and iris recognition based on AAPSO with SVM (AAPSO-SVM). In the face and iris recognition systems, performance is evaluated using two human face databases, YALE and CASIA, and the UBiris dataset. In this method, we initially perform feature extraction and then recognition on the extracted features. In the recognition process, the extracted features are used for SVM training and testing. During the training and testing, the SVM parameters are optimized with the AAPSO technique, and in AAPSO, the acceleration coefficients are computed using the particle fitness values. The parameters in SVM, which are optimized by AAPSO, perform efficiently for both face and iris recognition. A comparative analysis between our proposed AAPSO-SVM and the PSO-SVM technique is presented. PMID:24790584

  13. Detection and imaging of corrosion around wing skin fasteners using the dripless bubbler ultrasonic scanner

    NASA Astrophysics Data System (ADS)

    Hsu, David K.; Barnard, Daniel J.

    1998-03-01

    The galvanic action between steel fasteners and aluminum wing skins of aircraft often leads to hidden exfoliation corrosion around the countersink surface of the fastener heads. To detect and evaluate the severity of such corrosion defects, the Dripless Bubbler ultrasonic scanner was applied. This technique uses a focused beam of high frequency ultrasound in a closed-cycle, water-coupled scan of wing skin test panels containing corroded and uncorroded fasteners. With full waveform acquisition, not only the lateral extent but also the depth profile of the corrosions around the fastener heads were mapped out, subject to shadowing of defects at different depth. The technique is capable of providing quantitative assessment of the severity of the corrosion. In tests conducted to evaluate different techniques, the Dripless Bubbler has shown high probability of detection and low false call rate. The presence of paint on the surface did not degrade the performance of the technique. In addition, the Dripless Bubbler was also used on wing skin panels containing repair 'blend-out' regions that had 0.020' to 0.100' of metal removed from the surface by grinding. Corrosions around fasteners in the blend-out regions were also detected.

  14. Evaluation of marginal gap of Ni-Cr copings made with conventional and accelerated casting techniques.

    PubMed

    Tannamala, Pavan Kumar; Azhagarasan, Nagarasampatti Sivaprakasam; Shankar, K Chitra

    2013-01-01

    Conventional casting techniques following the manufacturers' recommendations are time consuming. Accelerated casting techniques have been reported, but their accuracy with base metal alloys has not been adequately studied. We measured the vertical marginal gap of nickel-chromium copings made by conventional and accelerated casting techniques and determined the clinical acceptability of the cast copings in this study. Experimental design, in vitro study, lab settings. Ten copings each were cast by conventional and accelerated casting techniques. All copings were identical, only their mold preparation schedules differed. Microscopic measurements were recorded at ×80 magnification on the perpendicular to the axial wall at four predetermined sites. The marginal gap values were evaluated by paired t test. The mean marginal gap by conventional technique (34.02 μm) is approximately 10 μm lesser than that of accelerated casting technique (44.62 μm). As the P value is less than 0.0001, there is highly significant difference between the two techniques with regard to vertical marginal gap. The accelerated casting technique is time saving and the marginal gap measured was within the clinically acceptable limits and could be an alternative to time-consuming conventional techniques.

  15. Exploring Modeling Options and Conversion of Average Response to Appropriate Vibration Envelopes for a Typical Cylindrical Vehicle Panel with Rib-stiffened Design

    NASA Technical Reports Server (NTRS)

    Harrison, Phil; LaVerde, Bruce; Teague, David

    2009-01-01

    Although applications for Statistical Energy Analysis (SEA) techniques are more widely used in the aerospace industry today, opportunities to anchor the response predictions using measured data from a flight-like launch vehicle structure are still quite valuable. Response and excitation data from a ground acoustic test at the Marshall Space Flight Center permitted the authors to compare and evaluate several modeling techniques available in the SEA module of the commercial code VA One. This paper provides an example of vibration response estimates developed using different modeling approaches to both approximate and bound the response of a flight-like vehicle panel. Since both vibration response and acoustic levels near the panel were available from the ground test, the evaluation provided an opportunity to learn how well the different modeling options can match band-averaged spectra developed from the test data. Additional work was performed to understand the spatial averaging of the measurements across the panel from measured data. Finally an evaluation/comparison of two conversion approaches from the statistical average response results that are output from an SEA analysis to a more useful envelope of response spectra appropriate to specify design and test vibration levels for a new vehicle.

  16. [The contribution made by neurophysiological and ultrasound imaging studies to the diagnosis of carpal tunnel syndrome. Surgical correlation].

    PubMed

    de Pablos, C; Velasco-Zarzosa, M; Landeras-Alvaro, R; Rubio-Lorenzo, M; Martínez-Zubieta, P

    Electrophysiological study has been for long time the elected approach for the diagnosis and clinical evaluation of carpal tunnel syndrome (CTS). More recently, echography and other imaging techniques have been introduced in current medicine for their potential in the anatomical evaluation of the neural compression. To asses the usefulness of both diagnostic procedures we have compared the findings obtained by electrophysiological and echographic approaches in a group of 60 CTS patients with different degrees of the disease. In all patients the conduction velocity was evaluated in the median and cubital nerves using surface electrodes. For echography lineal transductors of 5-10 Hz and 5-12.5 MHz were employed. The patients were distributed for each test on a scale depending of the severity of the alterations detected by the corresponding technique and both files were subsequently compared by regression analysis, Pearson test and paired-test. No correlation was detected in any of the statistical test. The lack of correlation between the results of both proofs emphasizes the usefulness of the two diagnostic approaches in CTS. While electrophysiological study provides information about nerve function, ecography unravels the morphological alterations accounting for the syndrome, therefore being non-excluding complementary approaches.

  17. Thermal Integration of a Liquid Acquisition Device into a Cryogenic Feed System

    NASA Technical Reports Server (NTRS)

    Hastings, L. J.; Bolshinskiy, L. G.; Schunk, R. G.; Martin, A. K.; Eskridge, R. H.; Frenkel, A.; Grayson, G.; Pendleton, M. L.

    2011-01-01

    Primary objectives of this effort were to define the following: (1) Approaches for quantification of the accumulation of thermal energy within a capillary screen liquid acquisition device (LAD) for a lunar lander upper stage during periods of up to 210 days on the lunar surface, (2) techniques for mitigating heat entrapment, and (3) perform initial testing, data evaluation. The technical effort was divided into the following categories: (1) Detailed thermal modeling of the LAD/feed system interactions using both COMSOL computational fluid device and standard codes, (2) FLOW-3D modeling of bulk liquid to provide interfacing conditions for the LAD thermal modeling, (3) condensation conditioning of capillary screens to stabilize surface tension retention capability, and (4) subscale testing of an integrated LAD/feed system. Substantial progress was achieved in the following technical areas: (1) Thermal modeling and experimental approaches for evaluating integrated cryogen LAD/feed systems, at both the system and component levels, (2) reduced gravity pressure control analyses, (3) analytical modeling and testing for capillary screen conditioning using condensation and wicking, and (4) development of rapid turnaround testing techniques for evaluating LAD/feed system thermal and fluid integration. A comprehensive effort, participants included a diverse cross section of representatives from academia, contractors, and multiple Marshall Space Flight Center organizations.

  18. Develop real-time dosimetry concepts and instrumentation for long term missions

    NASA Technical Reports Server (NTRS)

    Braby, L. A.

    1982-01-01

    The development of a rugged portable instrument to evaluate dose and dose equivalent is described. A tissue-equivalent proportional counter simulating a 2 micrometer spherical tissue volume was operated satisfactorily for over a year. The basic elements of the electronic system were designed and tested. And finally, the most suitable mathematical technique for evaluating dose equivalent with a portable instrument was selected. Design and fabrication of a portable prototype, based on the previously tested circuits, is underway.

  19. Solid polymer electrolyte (SPE) fuel cell technology program, phase 2/2A. [testing and evaluations

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Test evaluations were performed on a fabricated single solid polymer electrolyte cell unit. The cell operated at increased current density and at higher performance levels. This improved performance was obtained through a combination of increased temperature, increased reactant pressures, improved activation techniques and improved thermal control over the baseline cell configuration. The cell demonstrated a higher acid content membrane which resulted in increased performance. Reduced catalyst loading and low cost membrane development showed encouraging results.

  20. Evaluation of the three-dimensional accuracy of implant impression techniques in two simulated clinical conditions by optical scanning.

    PubMed

    Sabouhi, Mahmoud; Bajoghli, Farshad; Abolhasani, Majid

    2015-01-01

    The success of an implant-supported prosthesis is dependent on the passive fit of its framework fabricated on a precise cast. The aim of this in vitro study was to digitally compare the three-dimensional accuracy of implant impression techniques in partially and completely edentulous conditions. The master model simulated two clinical conditions. The first condition was a partially edentulous mandibular arch with an anterior edentulous space (D condition). Two implant analogs were inserted in bilateral canine sites. After elimination of the teeth, the model was converted to a completely edentulous condition (E condition). Three different impression techniques were performed (open splinted [OS], open unsplinted [OU], closed [C]) for each condition. Six groups of casts (DOS, DOU, DC, EOS, EOU, EC) (n = 8), totaling 48 casts, were made. Two scan bodies were secured onto the master edentulous model and onto each test cast and digitized by an optical scanning system. The related scans were superimposed, and the mean discrepancy for each cast was determined. The statistical analysis showed no significant difference in the accuracy of casts as a function of model status (P = .78, analysis of variance [ANOVA] test), impression technique (P = .57, ANOVA test), or as the combination of both (P = .29, ANOVA test). The distribution of data was normal (Kolmogorov-Smirnov test). Model status (dentate or edentulous) and impression technique did not influence the precision of the casts. There is no difference among any of the impression techniques in either simulated clinical condition.

  1. A pressure-packer system for conducting rising head tests in water table wells

    USGS Publications Warehouse

    Levy, Benjamin S.; Pannell, Lawrence J.; Dadoly, John P.

    1993-01-01

    The pressure system developed for fully-saturated well screens has been modified for conducting rising head tests in water table wells installed in highly permeable aquifers. The pressure system consists of a compressed air source and 1 inch diameter PVC piping with a packer attached at the end. The pressure system was evaluated in a series of rising head tests conducted in a well at a Superfund site in New England. The well was tested with slugs and with the pressure system. Within each technique, estimates of hydraulic conductivity showed no difference. Comparison of hydraulic conductivity estimates between techniques (slug test vs. pressure test) showed differences due to stratigraphy. The interval tested using slug tests crossed two stratigraphic units; the pressure system tested only one of these units. We conclude that the pressure system may be used to characterize the vertical hydraulic conductivity distribution in a series of successive tests by changing the packer position and the screened interval tested.

  2. Antibody detection tests improve the sensitivity of tuberculosis diagnosis in cattle.

    PubMed

    Casal, C; Infantes, J A; Risalde, M A; Díez-Guerrier, A; Domínguez, M; Moreno, I; Romero, B; de Juan, L; Sáez, J L; Juste, R; Gortázar, C; Domínguez, L; Bezos, J

    2017-06-01

    We evaluated the sensitivity (Se) of the single cervical intradermal tuberculin (SIT) test, two interferon-gamma (IFN-γ) assays and three different antibody detection techniques for bovine tuberculosis (bTB) diagnosis in 131 mixed beef breed cattle. The results of the diagnostic techniques performed over the whole herd, and over the animals confirmed as infected based on the presence of lesions compatible with the disease and/or M. bovis isolation were compared to determine apparent prevalence (AP) and Se. The Se of the SIT test (severe interpretation) was 63.7% (95% CI, 54.54-72.00), while the Se of the IFN-γ assays ranged between 60.2% and 92%. The proportion of infected cattle detected by the different antibody detection techniques ranged from 65.5% to 87.6%. Three of the antibody detection techniques yielded a significant higher (p<0.05) Se than that achieved with the official diagnostic techniques. In addition, the interpretation in parallel of cellular and antibody detection techniques reached the highest Se: 98.2% (95% CI, 93.78-99.51) suggesting that the use of diagnostic techniques detecting both cellular and humoral responses could be considered as an alternative in the control of bTB outbreaks in high prevalence settings. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Developing the Fourth Evaluation Dimension: A Protocol for Evaluation of Video From the Patient's Perspective During Major Incident Exercises.

    PubMed

    Haverkort, J J Mark; Leenen, Luke P H

    2017-10-01

    Presently used evaluation techniques rely on 3 traditional dimensions: reports from observers, registration system data, and observational cameras. Some of these techniques are observer-dependent and are not reproducible for a second review. This proof-of-concept study aimed to test the feasibility of extending evaluation to a fourth dimension, the patient's perspective. Footage was obtained during a large, full-scale hospital trauma drill. Two mock victims were equipped with point-of-view cameras filming from the patient's head. Based on the Major Incident Hospital's first experience during the drill, a protocol was developed for a prospective, standardized method to evaluate a hospital's major incident response from the patient's perspective. The protocol was then tested in a second drill for its feasibility. New insights were gained after review of the footage. The traditional observer missed some of the evaluation points, which were seen on the point-of-view cameras. The information gained from the patient's perspective proved to be implementable into the designed protocol. Use of point-of-view camera recordings from a mock patient's perspective is a valuable addition to traditional evaluation of trauma drills and trauma care. Protocols should be designed to optimize and objectify judgement of such footage. (Disaster Med Public Health Preparedness. 2017;11:594-599).

  4. Machine Learning Based Evaluation of Reading and Writing Difficulties.

    PubMed

    Iwabuchi, Mamoru; Hirabayashi, Rumi; Nakamura, Kenryu; Dim, Nem Khan

    2017-01-01

    The possibility of auto evaluation of reading and writing difficulties was investigated using non-parametric machine learning (ML) regression technique for URAWSS (Understanding Reading and Writing Skills of Schoolchildren) [1] test data of 168 children of grade 1 - 9. The result showed that the ML had better prediction than the ordinary rule-based decision.

  5. Computer measurement of arterial disease

    NASA Technical Reports Server (NTRS)

    Armstrong, J.; Selzer, R. H.; Barndt, R.; Blankenhorn, D. H.; Brooks, S.

    1980-01-01

    Image processing technique quantifies human atherosclerosis by computer analysis of arterial angiograms. X-ray film images are scanned and digitized, arterial shadow is tracked, and several quantitative measures of lumen irregularity are computed. In other tests, excellent agreement was found between computer evaluation of femoral angiograms on living subjects and evaluation by teams of trained angiographers.

  6. Using Rasch Analysis to Identify Uncharacteristic Responses to Undergraduate Assessments

    ERIC Educational Resources Information Center

    Edwards, Antony; Alcock, Lara

    2010-01-01

    Rasch Analysis is a statistical technique that is commonly used to analyse both test data and Likert survey data, to construct and evaluate question item banks, and to evaluate change in longitudinal studies. In this article, we introduce the dichotomous Rasch model, briefly discussing its assumptions. Then, using data collected in an…

  7. Laboratory evaluation techniques to investigate the spatial potential of repellents for push & pull mosquito control systems

    USDA-ARS?s Scientific Manuscript database

    A protocol has been developed for the indoor evaluation of candidate spatial repellents intended for use in push and pull systems. Single treatments (catnip oil, 1-methylpiperazine and homopiperazine) and a mixture of catnip oil and homopiperazine were tested with yellow-fever mosquitoes (Aedes aegy...

  8. Nondestructive test of regenerative chambers

    NASA Technical Reports Server (NTRS)

    Malone, G. A.; Stauffis, R.; Wood, R.

    1972-01-01

    Flat panels simulating internally cooled regenerative thrust chamber walls were fabricated by electroforming, brazing and diffusion bonding to evaluate the feasibility of nondestructive evaluation techniques to detect bonds of various strength integrities. Ultrasonics, holography, and acoustic emission were investigated and found to yield useful and informative data regarding the presence of bond defects in these structures.

  9. Evaluation of fluorescent-antibody tests as a means of confirming infant botulism.

    PubMed Central

    Glasby, C; Hatheway, C L

    1984-01-01

    Fluorescent-antibody techniques were evaluated for confirming infant botulism. Seventy-seven stool specimens from suspected cases were examined. All 34 specimens containing viable Clostridium botulinum at time of study gave positive results (29 on direct smears and 34 on enrichments). Two false-positive reactions were observed. Images PMID:6394626

  10. Nondestructive Integrity Evaluation of PC Pile Using Wigner-Ville Distribution Method

    NASA Astrophysics Data System (ADS)

    Ni, Sheng-Huoo; Lo, Kuo-Feng; Huang, Yan-Hong

    Nondestructive evaluation (NDE) techniques have been used for years to provide a quality control of the construction for both drilled shafts and driven concrete piles. This trace is typically made up of transient pulses reflected from structural features of the pile or changes in its surrounding environment. It is often analyzed in conjunction with the spectral response, mobility curve, arrival time, etc. The Wigner-Ville Distribution is a new numerical analysis tool for signal process technique in the time-frequency domain and it can offer assistance and enhance signal characteristics for better resolution both easily and quickly. In this study, five single pre-cast concrete piles have been tested and evaluated by both sonic echo method and Wigner-Ville distribution (WVD). Furthermore, two difficult problems in nondestructive evaluation problems are discussed and solved: the first one is with a pile with slight defect, whose necking area percentage is less than 10%, and the other is a pile with multiple defects. The results show that WVD can not only recognize the characteristics easily, but also locate the defects more clearly than the traditional pile integrity testing method.

  11. Application of machine vision to pup loaf bread evaluation

    NASA Astrophysics Data System (ADS)

    Zayas, Inna Y.; Chung, O. K.

    1996-12-01

    Intrinsic end-use quality of hard winter wheat breeding lines is routinely evaluated at the USDA, ARS, USGMRL, Hard Winter Wheat Quality Laboratory. Experimental baking test of pup loaves is the ultimate test for evaluating hard wheat quality. Computer vision was applied to developing an objective methodology for bread quality evaluation for the 1994 and 1995 crop wheat breeding line samples. Computer extracted features for bread crumb grain were studied, using subimages (32 by 32 pixel) and features computed for the slices with different threshold settings. A subsampling grid was located with respect to the axis of symmetry of a slice to provide identical topological subimage information. Different ranking techniques were applied to the databases. Statistical analysis was run on the database with digital image and breadmaking features. Several ranking algorithms and data visualization techniques were employed to create a sensitive scale for porosity patterns of bread crumb. There were significant linear correlations between machine vision extracted features and breadmaking parameters. Crumb grain scores by human experts were correlated more highly with some image features than with breadmaking parameters.

  12. SimulCAT: Windows Software for Simulating Computerized Adaptive Test Administration

    ERIC Educational Resources Information Center

    Han, Kyung T.

    2012-01-01

    Most, if not all, computerized adaptive testing (CAT) programs use simulation techniques to develop and evaluate CAT program administration and operations, but such simulation tools are rarely available to the public. Up to now, several software tools have been available to conduct CAT simulations for research purposes; however, these existing…

  13. Forecasting Techniques and Library Circulation Operations: Implications for Management.

    ERIC Educational Resources Information Center

    Ahiakwo, Okechukwu N.

    1988-01-01

    Causal regression and time series models were developed using six years of data for home borrowing, average readership, and books consulted at a university library. The models were tested for efficacy in producing short-term planning and control data. Combined models were tested in establishing evaluation measures. (10 references) (Author/MES)

  14. Simulating the Effects of Common and Specific Abilities on Test Performance: An Evaluation of Factor Analysis

    ERIC Educational Resources Information Center

    McFarland, Dennis J.

    2014-01-01

    Purpose: Factor analysis is a useful technique to aid in organizing multivariate data characterizing speech, language, and auditory abilities. However, knowledge of the limitations of factor analysis is essential for proper interpretation of results. The present study used simulated test scores to illustrate some characteristics of factor…

  15. Determining the minimum in situ stress from hydraulic fracturing through perforations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warpinski, N.R.

    Hydraulic fracture stress measurements have been performed through perforations at depths from 1310 to 2470 m at the US Department of Energy's Multiwell Experiment site. The results of over sixty stress tests conducted through perforations have shown that small-volume hydraulic fractures generally provide an accurate, reproducible measurement of the minimum in situ stress. However, unusual behavior can occur in some tests and techniques to evaluate the behavior are suggested. Unclear instantaneous shut-in pressures, which are found on occasional tests, are difficult to evaluate, but the problem appears to be a complex stress state; reprocessing the data using log-log or othermore » functions does not necessarily provide the correct stress value. The possible error in such tests should be assessed from the original pressure-time data and not the reprocessing techniques. Stress results show that the stress distribution is dependent on lithology at this site; mudstones, shales and other nonreservoir rocks generally have a near-lithostatic stress, while sandstones have a considerably lower minimum stress value. 30 refs., 18 figs., 4 tabs.« less

  16. Comparing the performance of circulating cathodic antigen and Kato-Katz techniques in evaluating Schistosoma mansoni infection in areas with low prevalence in selected counties of Kenya: a cross-sectional study.

    PubMed

    Okoyo, Collins; Simiyu, Elses; Njenga, Sammy M; Mwandawiro, Charles

    2018-04-11

    Kato-Katz technique has been the mainstay test in Schistosoma mansoni diagnosis in endemic areas. However, recent studies have documented its poor sensitivity in evaluating Schistosoma mansoni infection especially in areas with lower rates of transmission. It's the primary diagnostic tool in monitoring impact of the Kenya national school based deworming program on infection transmission, but there is need to consider a more sensitive technique as the prevalence reduces. Therefore, this study explored the relationship between results of the stool-based Kato-Katz technique with urine-based point-of-care circulating cathodic antigen (POC-CCA) test in view to inform decision-making by the program in changing from Kato-Katz to POC-CCA test. We used two cross-sectional surveys conducted pre- and post- mass drug administration (MDA) using praziquantel in a representative random sample of children from 18 schools across 11 counties. A total of 1944 children were randomly sampled for the study. Stool and urine samples were tested for S. mansoni infection using Kato-Katz and POC-CCA methods, respectively. S. mansoni prevalence using each technique was calculated and 95% confidence intervals obtained using binomial regression model. Specificity (Sp) and sensitivity (Sn) were determined using 2 × 2 contingency tables and compared using the McNemar's chi-square test. A total of 1899 and 1878 children were surveyed at pre- and post-treatment respectively. S. mansoni infection prevalence was 26.5 and 21.4% during pre- and post-treatment respectively using POC-CCA test, and 4.9 and 1.5% for pre- and post-treatment respectively using Kato-Katz technique. Taking POC-CCA as the gold standard, Kato-Katz was found to have significantly lower sensitivity both at pre- and post-treatment, Sn = 12.5% and Sn = 5.2% respectively, McNemar test χ 2 m  = 782.0, p < 0.001. In overall, the results showed a slight/poor agreement between the two methods, kappa index (k) = 0.11, p < 0.001, inter-rater agreement = 77.1%. Results showed POC-CCA technique as an effective, sensitive and accurate screening tool for Schistosoma mansoni infection in areas of low prevalence. It was up to 14-fold accurate than Kato-Katz which had extremely inadequate sensitivity. We recommend usage of POC-CCA alongside Kato-Katz examinations by Schistosomiasis control programs in low prevalence areas.

  17. In vitro assessment of polymerization procedures in Class II restorations: sealing, FTIR, and microhardness evaluations.

    PubMed

    Tassery, H; de Donato, P; Barrès, O; Déjou, J

    2001-01-01

    This study was undertaken to evaluate several polymerization and filling procedures (incremental, bulk, light-tip, soft-cured, plasma devices) in Class II restorations through (1) a sealing evaluation of restorations filled with Tetric Ceram (TC) and Bisfil 2B (B2B, self-cured composite used as a control), (2) a FTIR analysis measuring the variations of the degree of conversion in terms of area unit ratio of the relevant resin composites and (3) a microhardness test to corroborate the FTIR analysis. The length of the tracer penetration was measured from the gingival margin up to the cavity wall with an episcope on sectioned teeth. A ceramic mould, simulating a Class II, was filled according to the different groups and the samples were analyzed with a Bruker IFS 55 spectrometer on ultrathin sections (3 mu). The results were analyzed in terms of area unit ratio and total exposed energy. Under the same conditions, a microhardness test was run with a Frank Weihem machine. The results of the sealing evaluation for light-tip, incremental and self-cured techniques did not differ. The plasma procedure failed in this evaluation as the bottom increment was not polymerized. The smallest area unit ratio (the best degree of conversion) was observed in 2 groups: one, the combination of the light-tip and soft process, and two, the self-cured resin composite (B2B). The distance at which the plasma procedure failed to cure the resin composite was between 3.5 and 4.5 mm. The microhardness test confirmed the FTIR analysis except for the group G2 (TC + light-tip). As also shown by FTIR analysis, no difference between the two relevant levels was observed with the hardness test. The dentin marginal sealing efficiency of Tetric Ceram restorations was increased with the light-tip technique, but was not better than the self-cured resin composite (B2B). For Tetric Ceram, the combination of the light-tip and soft process leads to a higher degree of conversion than the other groups. There is no linear relationship between the degree of conversion, the microhardness and the total exposed energy. The combination of the soft polymerization and the light-tip device might be an alternative restorative technique to the current incremental technique.

  18. Evaluation of three different decontamination techniques on biofilm formation, and on physical and chemical properties of resin composites.

    PubMed

    André, Carolina Bosso; Dos Santos, Andressa; Pfeifer, Carmem Silvia; Giannini, Marcelo; Girotto, Emerson Marcelo; Ferracane, Jack Liborio

    2018-04-01

    This study evaluated three different sterilization/disinfection techniques for resin composites on bacterial growth and surface modification after decontamination. Two resin composites were sterilized/disinfected with three different techniques: UV light, 1% chloramine T, and 70% ethanol. Four different times were used for each technique to determine the shortest time that the solution or UV light was effective. The influence of sterilization/disinfection technique on bacterial growth was evaluated by analyzing the metabolic activity, using the AlamarBlue™ assay, bacterial viability, and SEM images from biofilms of Streptococcus mutans. The surface change, after the process, was analyzed with ATR/FTIR and SEM images. The solutions used for decontamination (1% chloramine-T and 70% ethanol) were analyzed with 1 H-NMR to identify any resin compounds leached during the process. One minute of decontamination was efficient for all three methods tested. Chloramine-T increased the surface porosity on resin composites, no changes were observed for UV light and 70% ethanol, however, 1 H-NMR identified leached monomers only when 70% ethanol was used. No chemical change of the materials was found under ATR/FTIR analyses after the decontamination process. Chloramine-T, with no previous wash, increased the bacterial viability for both resin composites and increased the bacterial metabolism for the resin composite without fluoride. UV light had no interference on the resin composites properties tested using 1 min of exposure compared to the other decontamination methods. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 945-953, 2018. © 2017 Wiley Periodicals, Inc.

  19. Report of the Aircraft Systems/Flight Test Workshop Held at East Point, Georgia on 8-17 November 1977.

    DTIC Science & Technology

    1977-11-01

    prior knowledge to decrease the amount of manpower and time required to evaluate the second package, but in principle, each STC package must be...techniques. Our knowledge of the problems, hazards, and pitfalls in the use of these techniques is very limited. Background: We do not have sufficient...prediction techniques, and what recommendations we would like to make, based on the limited knowledge we currently have. I would really like to spend another

  20. Limited Qualities Evaluation of Longitudinal Flight Control Systems Designed Using Multiobjective Control Design Techniques (HAVE INFINITY II)

    DTIC Science & Technology

    1998-06-01

    analytical phase of this research. Finally, the mixed H2/H-Infinity method optimally tradeoff the different benefits offered by the separate H2 and H...potential benefits of the multiobjective design techniques used. Due to the HAVE INFINITY I test results, AFIT made the decision to continue the...sensitivity and complimentary sensitivity weighting, and a mixed H2/H-Infinity design that compromised the benefits of both design techniques optimally. The

  1. Simulation verification techniques study: Simulation performance validation techniques document. [for the space shuttle system

    NASA Technical Reports Server (NTRS)

    Duncan, L. M.; Reddell, J. P.; Schoonmaker, P. B.

    1975-01-01

    Techniques and support software for the efficient performance of simulation validation are discussed. Overall validation software structure, the performance of validation at various levels of simulation integration, guidelines for check case formulation, methods for real time acquisition and formatting of data from an all up operational simulator, and methods and criteria for comparison and evaluation of simulation data are included. Vehicle subsystems modules, module integration, special test requirements, and reference data formats are also described.

  2. Field Data Collection: an Essential Element in Remote Sensing Applications

    NASA Technical Reports Server (NTRS)

    Pettinger, L. R.

    1971-01-01

    Field data collected in support of remote sensing projects are generally used for the following purposes: (1) calibration of remote sensing systems, (2) evaluation of experimental applications of remote sensing imagery on small test sites, and (3) designing and evaluating operational regional resource studies and inventories which are conducted using the remote sensing imagery obtained. Field data may be used to help develop a technique for a particular application, or to aid in the application of that technique to a resource evaluation or inventory problem for a large area. Scientists at the Forestry Remote Sensing Laboratory have utilized field data for both purposes. How meaningful field data has been collected in each case is discussed.

  3. Extending the Distributed Lag Model framework to handle chemical mixtures.

    PubMed

    Bello, Ghalib A; Arora, Manish; Austin, Christine; Horton, Megan K; Wright, Robert O; Gennings, Chris

    2017-07-01

    Distributed Lag Models (DLMs) are used in environmental health studies to analyze the time-delayed effect of an exposure on an outcome of interest. Given the increasing need for analytical tools for evaluation of the effects of exposure to multi-pollutant mixtures, this study attempts to extend the classical DLM framework to accommodate and evaluate multiple longitudinally observed exposures. We introduce 2 techniques for quantifying the time-varying mixture effect of multiple exposures on an outcome of interest. Lagged WQS, the first technique, is based on Weighted Quantile Sum (WQS) regression, a penalized regression method that estimates mixture effects using a weighted index. We also introduce Tree-based DLMs, a nonparametric alternative for assessment of lagged mixture effects. This technique is based on the Random Forest (RF) algorithm, a nonparametric, tree-based estimation technique that has shown excellent performance in a wide variety of domains. In a simulation study, we tested the feasibility of these techniques and evaluated their performance in comparison to standard methodology. Both methods exhibited relatively robust performance, accurately capturing pre-defined non-linear functional relationships in different simulation settings. Further, we applied these techniques to data on perinatal exposure to environmental metal toxicants, with the goal of evaluating the effects of exposure on neurodevelopment. Our methods identified critical neurodevelopmental windows showing significant sensitivity to metal mixtures. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. In vivo evaluation of inter-operator reproducibility of digital dental and conventional impression techniques.

    PubMed

    Kamimura, Emi; Tanaka, Shinpei; Takaba, Masayuki; Tachi, Keita; Baba, Kazuyoshi

    2017-01-01

    The aim of this study was to evaluate and compare the inter-operator reproducibility of three-dimensional (3D) images of teeth captured by a digital impression technique to a conventional impression technique in vivo. Twelve participants with complete natural dentition were included in this study. A digital impression of the mandibular molars of these participants was made by two operators with different levels of clinical experience, 3 or 16 years, using an intra-oral scanner (Lava COS, 3M ESPE). A silicone impression also was made by the same operators using the double mix impression technique (Imprint3, 3M ESPE). Stereolithography (STL) data were directly exported from the Lava COS system, while STL data of a plaster model made from silicone impression were captured by a three-dimensional (3D) laboratory scanner (D810, 3shape). The STL datasets recorded by two different operators were compared using 3D evaluation software and superimposed using the best-fit-algorithm method (least-squares method, PolyWorks, InnovMetric Software) for each impression technique. Inter-operator reproducibility as evaluated by average discrepancies of corresponding 3D data was compared between the two techniques (Wilcoxon signed-rank test). The visual inspection of superimposed datasets revealed that discrepancies between repeated digital impression were smaller than observed with silicone impression. Confirmation was forthcoming from statistical analysis revealing significantly smaller average inter-operator reproducibility using a digital impression technique (0.014± 0.02 mm) than when using a conventional impression technique (0.023 ± 0.01 mm). The results of this in vivo study suggest that inter-operator reproducibility with a digital impression technique may be better than that of a conventional impression technique and is independent of the clinical experience of the operator.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parrado, G., E-mail: gparrado@sgc.gov.co; Cañón, Y.; Peña, M., E-mail: mlpena@sgc.gov.co

    The Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey has developed a technique for multi-elemental analysis of soil and plant matrices, based on Instrumental Neutron Activation Analysis (INAA) using the comparator method. In order to evaluate the analytical capabilities of the technique, the laboratory has been participating in inter-comparison tests organized by Wepal (Wageningen Evaluating Programs for Analytical Laboratories). In this work, the experimental procedure and results for the multi-elemental analysis of four soil and four plant samples during participation in the first round on 2015 of Wepal proficiency test are presented. Only elements with radioactive isotopes withmore » medium and long half-lives have been evaluated, 15 elements for soils (As, Ce, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Th, U and Zn) and 7 elements for plants (Br, Co, Cr, Fe, K, Na and Zn). The performance assessment by Wepal based on Z-score distributions showed that most results obtained |Z-scores| ≤ 3.« less

  6. Reliability of Craniofacial Superimposition Using Three-Dimension Skull Model.

    PubMed

    Gaudio, Daniel; Olivieri, Lara; De Angelis, Danilo; Poppa, Pasquale; Galassi, Andrea; Cattaneo, Cristina

    2016-01-01

    Craniofacial superimposition is a technique potentially useful for the identification of unidentified human remains if a photo of the missing person is available. We have tested the reliability of the 2D-3D computer-aided nonautomatic superimposition techniques. Three-dimension laser scans of five skulls and ten photographs were overlaid with an imaging software. The resulting superimpositions were evaluated using three methods: craniofacial landmarks, morphological features, and a combination of the two. A 3D model of each skull without its mandible was tested for superimposition; we also evaluated whether separating skulls by sex would increase correct identifications. Results show that the landmark method employing the entire skull is the more reliable one (5/5 correct identifications, 40% false positives [FP]), regardless of sex. However, the persistence of a high percentage of FP in all the methods evaluated indicates that these methods are unreliable for positive identification although the landmark-only method could be useful for exclusion. © 2015 American Academy of Forensic Sciences.

  7. Improvement of analytical capabilities of neutron activation analysis laboratory at the Colombian Geological Survey

    NASA Astrophysics Data System (ADS)

    Parrado, G.; Cañón, Y.; Peña, M.; Sierra, O.; Porras, A.; Alonso, D.; Herrera, D. C.; Orozco, J.

    2016-07-01

    The Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey has developed a technique for multi-elemental analysis of soil and plant matrices, based on Instrumental Neutron Activation Analysis (INAA) using the comparator method. In order to evaluate the analytical capabilities of the technique, the laboratory has been participating in inter-comparison tests organized by Wepal (Wageningen Evaluating Programs for Analytical Laboratories). In this work, the experimental procedure and results for the multi-elemental analysis of four soil and four plant samples during participation in the first round on 2015 of Wepal proficiency test are presented. Only elements with radioactive isotopes with medium and long half-lives have been evaluated, 15 elements for soils (As, Ce, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Th, U and Zn) and 7 elements for plants (Br, Co, Cr, Fe, K, Na and Zn). The performance assessment by Wepal based on Z-score distributions showed that most results obtained |Z-scores| ≤ 3.

  8. Assessment techniques for a learning-centered curriculum: evaluation design for adventures in supercomputing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Helland, B.; Summers, B.G.

    1996-09-01

    As the classroom paradigm shifts from being teacher-centered to being learner-centered, student assessments are evolving from typical paper and pencil testing to other methods of evaluation. Students should be probed for understanding, reasoning, and critical thinking abilities rather than their ability to return memorized facts. The assessment of the Department of Energy`s pilot program, Adventures in Supercomputing (AiS), offers one example of assessment techniques developed for learner-centered curricula. This assessment has employed a variety of methods to collect student data. Methods of assessment used were traditional testing, performance testing, interviews, short questionnaires via email, and student presentations of projects. Themore » data obtained from these sources have been analyzed by a professional assessment team at the Center for Children and Technology. The results have been used to improve the AiS curriculum and establish the quality of the overall AiS program. This paper will discuss the various methods of assessment used and the results.« less

  9. The evaluation of the optimization design and application effect of same-well-injection-production technique’s injection-production circulatory system

    NASA Astrophysics Data System (ADS)

    Guoxing, Zheng; Minghu, Jiang; Hongliang, Gong; Nannan, Zhang; Jianguang, Wei

    2018-02-01

    According to basic principles of combining series of strata and demands of same-well injection-production technique, the optimization designing method of same-well injection-production technique’s injection-production circulatory system is given. Based on oil-water two-phase model with condition of arbitrarily well network, a dynamic forecast method for the application of same-well injection-production reservoir is established with considering the demands and capacity of same-well injection-production technique, sample wells are selected to launch the forecast evaluation and analysis of same-well injection-production reservoir application’s effect. Results show: single-test-well composite water cut decreases by 4.7% and test-well-group composite water cut decreases by 1.56% under the condition of basically invariant ground water injection rate. The method provides theoretical support for the proof of same-well injection-production technique’s reservoir development improving effect and further tests.

  10. Implementation of 350-2500 nm diffuse reflectance spectroscopy and High-Performance Thin-Layer Chromatography to rapidly assess manufacturing consistency and quality of cotrimoxazole tablets in Tanzania.

    PubMed

    Kaale, Eliangiringa; Hope, Samuel M; Jenkins, David; Layloff, Thomas

    2016-01-01

    To assess the quality of cotrimoxazole tablets produced by a Tanzanian manufacturer by a newly instituted quality assurance programme. Tablets underwent a diffuse reflectance spectroscopy procedure with periodic quality assessment confirmation by assay and dissolution testing using validated HPTLC techniques (including weight variation and disintegration evaluations). Based on results from the primary test methods, the first group of product was <80% compliant, whereas subsequent groups reached >99% compliance. This approach provides a model for rapidly assuring product quality of future procurements of other products that is more cost-effective than traditional pharmaceutical testing techniques. © 2015 John Wiley & Sons Ltd.

  11. Real time flaw detection and characterization in tube through partial least squares and SVR: Application to eddy current testing

    NASA Astrophysics Data System (ADS)

    Ahmed, Shamim; Miorelli, Roberto; Calmon, Pierre; Anselmi, Nicola; Salucci, Marco

    2018-04-01

    This paper describes Learning-By-Examples (LBE) technique for performing quasi real time flaw localization and characterization within a conductive tube based on Eddy Current Testing (ECT) signals. Within the framework of LBE, the combination of full-factorial (i.e., GRID) sampling and Partial Least Squares (PLS) feature extraction (i.e., GRID-PLS) techniques are applied for generating a suitable training set in offine phase. Support Vector Regression (SVR) is utilized for model development and inversion during offine and online phases, respectively. The performance and robustness of the proposed GIRD-PLS/SVR strategy on noisy test set is evaluated and compared with standard GRID/SVR approach.

  12. Synthesis of active controls for flutter suppression on a flight research wing

    NASA Technical Reports Server (NTRS)

    Abel, I.; Perry, B., III; Murrow, H. N.

    1977-01-01

    This paper describes some activities associated with the preliminary design of an active control system for flutter suppression capable of demonstrating a 20% increase in flutter velocity. Results from two control system synthesis techniques are given. One technique uses classical control theory, and the other uses an 'aerodynamic energy method' where control surface rates or displacements are minimized. Analytical methods used to synthesize the control systems and evaluate their performance are described. Some aspects of a program for flight testing the active control system are also given. This program, called DAST (Drones for Aerodynamics and Structural Testing), employs modified drone-type vehicles for flight assessments and validation testing.

  13. A rotating hot-wire technique for spatial sampling of disturbed and manipulated duct flows

    NASA Technical Reports Server (NTRS)

    Wark, C. E.; Nagib, H. M.; Jennings, M. J.

    1990-01-01

    A duct flow spatial sampling technique, in which an X-wire probe is rotated about the center of a cylindrical test section at a radius equal to one-half that of the test section in order to furnish nearly instantaneous multipoint measurements of the streamwise and azimuthal components, is presently evaluated in view of the control of flow disturbances downstream of various open inlet contractions. The effectiveness of a particular contraction in controlling ingested flow disturbances was ascertained by artificially introducing disturbances upstream of the contractions; control effectiveness if found to be strongly dependent on inlet contraction, with consequences for the reduction of passing-blade frequency noise during gas turbine engine ground testing.

  14. TESTING OF A 20-METER SOLAR SAIL SYSTEM

    NASA Technical Reports Server (NTRS)

    Gaspar, J. L.; Behun, V.; Mann, T.; Murphy D.; Macy, B.

    2005-01-01

    This paper describes the structural dynamic tests conducted in-vacuum on the Scalable Square Solar Sail (S(sup 4)) System 20-meter test article developed by ATK Space Systems as part of a ground demonstrator system development program funded by NASA's In-Space Propulsion program1-3. These tests were conducted for the purpose of validating analytical models that would be required by a flight test program to predict in space performance4. Specific tests included modal vibration tests on the solar sail system in a 1 Torr vacuum environment using various excitation locations and techniques including magnetic excitation at the sail quadrant corners, piezoelectric stack actuation at the mast roots, spreader bar excitation at the mast tips, and bi-morph piezoelectric patch actuation on the sail cords. The excitation methods were evaluated for their suitability to in-vacuum ground testing and their traceability to the development of on-orbit flight test techniques. The solar sail masts were also tested in ambient atmospheric conditions and these results are also discussed.

  15. TESTING OF A 20-METER SOLAR SAIL SYSTEM

    NASA Technical Reports Server (NTRS)

    Gaspar, Jim L.; Behun, Vaughan; Mann, Troy; Murphy, Dave; Macy, Brian

    2005-01-01

    This paper describes the structural dynamic tests conducted in-vacuum on the Scalable Square Solar Sail (S(sup 4)) System 20-meter test article developed by ATK Space Systems as part of a ground demonstrator system development program funded by NASA's In-Space Propulsion program. These tests were conducted for the purpose of validating analytical models that would be required by a flight test program to predict in space performance. Specific tests included modal vibration tests on the solar sail system in a 1 Torr vacuum environment using various excitation locations and techniques including magnetic excitation at the sail quadrant corners, piezoelectric stack actuation at the mast roots, spreader bar excitation at the mast tips, and bi-morph piezoelectric patch actuation on the sail cords. The excitation methods are evaluated for their suitability to in-vacuum ground testing and their traceability to the development of on-orbit flight test techniques. The solar sail masts were also tested in ambient atmospheric conditions and these results are also discussed.

  16. The pattern and technique in the clinical evaluation of the adult hip: the common physical examination tests of hip specialists.

    PubMed

    Martin, Hal D; Kelly, Bryan T; Leunig, Michael; Philippon, Marc J; Clohisy, John C; Martin, RobRoy L; Sekiya, Jon K; Pietrobon, Ricardo; Mohtadi, Nicholas G; Sampson, Thomas G; Safran, Marc R

    2010-02-01

    The purpose of this study was to systematically evaluate the technique and tests used in the physical examination of the adult hip performed by multiple clinicians who regularly treat patients with hip problems and identify common physical examination patterns. The subjects included 5 men and 6 women with a mean age (+/-SD) of 29.8 +/- 9.4 years. They underwent physical examination of the hip by 6 hip specialists with a strong interest in hip-related problems. All examiners were blind to patient radiographs and diagnoses. Patient examinations were video recorded and reviewed. It was determined that 18 tests were most frequently performed (>or=40%) by the examiners, 3 standing, 11 supine, 3 lateral, and 1 prone. Of the most frequently performed tests, 10 were performed more than 50% of the time. The tests performed in the supine position were as follows: flexion range of motion (ROM) (percentage of use, 98%), flexion internal rotation ROM (98%), flexion external rotation ROM (86%), passive supine rotation test (76%), flexion/adduction/internal rotation test (70%), straight leg raise against resistance test (61%), and flexion/abduction/external rotation test (52%). The tests performed in the standing position were the gait test (86%) and the single-leg stance phase test (77%). The 1 test in the prone position was the femoral anteversion test (58%). There are variations in the testing that hip specialists perform to examine and evaluate their patients, but there is enough commonality to form the basis to recommend a battery of physical examination maneuvers that should be considered for use in evaluating the hip. Patients presenting with groin, abdominal, back, and/or hip pain need to have a basic examination to ensure that the hip is not overlooked. A comprehensive physical examination of the hip will benefit the patient and the physician and serve as the foundation for future multicenter clinical studies. (c) 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schaeffel, J.A.; Mullinix, B.R.; Ranson, W.F.

    An experimental technique to simulate and evaluate the effects of high concentrations of x-rays resulting from a nuclear detonation on missile structures is presented. Data from 34 tests are included to demonstrate the technique. The effects of variations in the foil thickness, capacitor voltage, and plate thickness on the total impulse and maximum strain in the structure were determined. The experimental technique utilizes a high energy capacitor discharge unit to explode an aluminum foil on the surface of the structure. The structural response is evaluated by optical methods using the grid slope deflection method. The fringe patterns were recorded usingmore » a high-speed framing camera. The data were digitized using an optical comparator with an x-y table. The analysis was performed on a CDC 6600 computer.« less

  18. Evaluating the Acoustic Effect of Over-the-Rotor Foam-Metal Liner Installed on a Low Speed Fan Using Virtual Rotating Microphone Imaging

    NASA Technical Reports Server (NTRS)

    Sutliff, Daniel L.; Dougherty, Robert P.; Walker, Bruce E.

    2010-01-01

    An in-duct beamforming technique for imaging rotating broadband fan sources has been used to evaluate the acoustic characteristics of a Foam-Metal Liner installed over-the-rotor of a low-speed fan. The NASA Glenn Research Center s Advanced Noise Control Fan was used as a test bed. A duct wall-mounted phased array consisting of several rings of microphones was employed. The data are mathematically resampled in the fan rotating reference frame and subsequently used in a conventional beamforming technique. The steering vectors for the beamforming technique are derived from annular duct modes, so that effects of reflections from the duct walls are reduced.

  19. Non-Destructive Evaluation of Depth of Surface Cracks Using Ultrasonic Frequency Analysis

    PubMed Central

    Her, Shiuh-Chuan; Lin, Sheng-Tung

    2014-01-01

    Ultrasonic is one of the most common uses of a non-destructive evaluation method for crack detection and characterization. The effectiveness of the acoustic-ultrasound Structural Health Monitoring (SHM) technique for the determination of the depth of the surface crack was presented. A method for ultrasonic sizing of surface cracks combined with the time domain and frequency spectrum was adopted. The ultrasonic frequency spectrum was obtained by Fourier transform technique. A series of test specimens with various depths of surface crack ranging from 1 mm to 8 mm was fabricated. The depth of the surface crack was evaluated using the pulse-echo technique. In this work, three different longitudinal waves with frequencies of 2.25 MHz, 5 MHz and 10 MHz were employed to investigate the effect of frequency on the sizing detection of surface cracks. Reasonable accuracies were achieved with measurement errors less than 7%. PMID:25225875

  20. Image analysis of neuropsychological test responses

    NASA Astrophysics Data System (ADS)

    Smith, Stephen L.; Hiller, Darren L.

    1996-04-01

    This paper reports recent advances in the development of an automated approach to neuropsychological testing. High performance image analysis algorithms have been developed as part of a convenient and non-invasive computer-based system to provide an objective assessment of patient responses to figure-copying tests. Tests of this type are important in determining the neurological function of patients following stroke through evaluation of their visuo-spatial performance. Many conventional neuropsychological tests suffer from the serious drawback that subjective judgement on the part of the tester is required in the measurement of the patient's response which leads to a qualitative neuropsychological assessment that can be both inconsistent and inaccurate. Results for this automated approach are presented for three clinical populations: patients suffering right hemisphere stroke are compared with adults with no known neurological disorder and a population comprising normal school children of 11 years is presented to demonstrate the sensitivity of the technique. As well as providing a more reliable and consistent diagnosis this technique is sufficiently sensitive to monitor a patient's progress over a period of time and will provide the neuropsychologist with a practical means of evaluating the effectiveness of therapy or medication administered as part of a rehabilitation program.

  1. Damage assessment in reinforced concrete using nonlinear vibration techniques

    NASA Astrophysics Data System (ADS)

    Van Den Abeele, K.; De Visscher, J.

    2000-07-01

    Reinforced concrete (RC) structures are subject to microcrack initiation and propagation at load levels far below the actual failure load. In this paper, nonlinear vibration techniques are applied to investigate stages of progressive damage in RC beams induced by static loading tests. At different levels of damage, a modal analysis is carried out, assuming the structure to behave linearly. At the same time, measurement of resonant frequencies and damping ratios as function of vibration amplitude are performed using a frequency domain technique as well as a time domain technique. We compare the results of the linear and nonlinear techniques, and value them against the visual damage evaluation.

  2. Machine-assisted verification of latent fingerprints: first results for nondestructive contact-less optical acquisition techniques with a CWL sensor

    NASA Astrophysics Data System (ADS)

    Hildebrandt, Mario; Kiltz, Stefan; Krapyvskyy, Dmytro; Dittmann, Jana; Vielhauer, Claus; Leich, Marcus

    2011-11-01

    A machine-assisted analysis of traces from crime scenes might be possible with the advent of new high-resolution non-destructive contact-less acquisition techniques for latent fingerprints. This requires reliable techniques for the automatic extraction of fingerprint features from latent and exemplar fingerprints for matching purposes using pattern recognition approaches. Therefore, we evaluate the NIST Biometric Image Software for the feature extraction and verification of contact-lessly acquired latent fingerprints to determine potential error rates. Our exemplary test setup includes 30 latent fingerprints from 5 people in two test sets that are acquired from different surfaces using a chromatic white light sensor. The first test set includes 20 fingerprints on two different surfaces. It is used to determine the feature extraction performance. The second test set includes one latent fingerprint on 10 different surfaces and an exemplar fingerprint to determine the verification performance. This utilized sensing technique does not require a physical or chemical visibility enhancement of the fingerprint residue, thus the original trace remains unaltered for further investigations. No particular feature extraction and verification techniques have been applied to such data, yet. Hence, we see the need for appropriate algorithms that are suitable to support forensic investigations.

  3. Evaluation of composite pavement unbonded overlays : phase III.

    DOT National Transportation Integrated Search

    2007-08-01

    In recent years, thin whitetopping has evolved as a viable rehabilitation technique for deteriorated asphalt cement concrete (ACC) pavements. Numerous projects have been constructed and tested, allowing researchers to identify the important elements ...

  4. Hand sensibility measures used by therapists.

    PubMed

    Mielke, K; Novak, C B; Mackinnon, S E; Feely, C A

    1996-03-01

    Sensory evaluations are frequently used to assess patients with functional loss resulting from nerve injury. The results of these tests are routinely utilized by hand surgeons as an indication for conservative management or surgical intervention in the evaluation of surgical outcome and in the determination of disability ratings. Reports in the literature regarding specific tests for sensibility show variation in their application. The purpose of this study was to evaluate which tests are used to evaluate hand sensibility and the techniques of application currently used by hand therapists. Two hundred members of the American Society of Hand Therapists were randomly selected and a survey was sent to these members. The results of this study identify the need to develop standardized protocols for sensory evaluations and the need for therapists to follow the standardized methods for administration of moving and static two-point discrimination, and Semmes-Weinstein monofilaments, if comparisons of results between centers are to be meaningful.

  5. Two biased estimation techniques in linear regression: Application to aircraft

    NASA Technical Reports Server (NTRS)

    Klein, Vladislav

    1988-01-01

    Several ways for detection and assessment of collinearity in measured data are discussed. Because data collinearity usually results in poor least squares estimates, two estimation techniques which can limit a damaging effect of collinearity are presented. These two techniques, the principal components regression and mixed estimation, belong to a class of biased estimation techniques. Detection and assessment of data collinearity and the two biased estimation techniques are demonstrated in two examples using flight test data from longitudinal maneuvers of an experimental aircraft. The eigensystem analysis and parameter variance decomposition appeared to be a promising tool for collinearity evaluation. The biased estimators had far better accuracy than the results from the ordinary least squares technique.

  6. Curve fitting air sample filter decay curves to estimate transuranic content.

    PubMed

    Hayes, Robert B; Chiou, Hung Cheng

    2004-01-01

    By testing industry standard techniques for radon progeny evaluation on air sample filters, a new technique is developed to evaluate transuranic activity on air filters by curve fitting the decay curves. The industry method modified here is simply the use of filter activity measurements at different times to estimate the air concentrations of radon progeny. The primary modification was to not look for specific radon progeny values but rather transuranic activity. By using a method that will provide reasonably conservative estimates of the transuranic activity present on a filter, some credit for the decay curve shape can then be taken. By carrying out rigorous statistical analysis of the curve fits to over 65 samples having no transuranic activity taken over a 10-mo period, an optimization of the fitting function and quality tests for this purpose was attained.

  7. Reading a standing wave: figure-ground-alternation masking of primes in evaluative priming.

    PubMed

    Bermeitinger, Christina; Kuhlmann, Michael; Wentura, Dirk

    2012-09-01

    We propose a new masking technique for masking word stimuli. Drawing on the phenomena of metacontrast and paracontrast, we alternately presented two prime displays of the same word with the background color in one display matching the font color in the other display and vice versa. The sequence of twenty alterations (spanning approx. 267 ms) was sandwich-masked by structure masks. Using this masking technique, we conducted evaluative priming experiments with positive and negative target and prime words. Significant priming effects were found - for primes and targets drawn from the same as well as from different word sets. Priming effects were independent of prime discrimination performance in direct tests and they were still significant after the sample was restricted to those participants who showed random responding in the direct test. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Radionuclide observables during the Integrated Field Exercise of the Comprehensive Nuclear-Test-Ban Treaty.

    PubMed

    Burnett, Jonathan L; Miley, Harry S; Milbrath, Brian D

    2016-03-01

    In 2014 the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) undertook an Integrated Field Exercise (IFE14) in Jordan. The exercise consisted of a simulated 0.5-2 kT underground nuclear explosion triggering an On-site Inspection (OSI) to search for evidence of a Treaty violation. This research paper evaluates two of the OSI techniques used during the IFE14, laboratory-based gamma-spectrometry of soil samples and in-situ gamma-spectrometry, both of which were implemented to search for 17 OSI relevant particulate radionuclides indicative of nuclear explosions. The detection sensitivity is evaluated using real IFE and model data. It indicates that higher sensitivity laboratory measurements are the optimum technique during the IFE and within the Treaty/Protocol-specified OSI timeframes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes

    PubMed Central

    2014-01-01

    Background The purpose of this study was to compare two impression techniques from the perspective of patient preferences and treatment comfort. Methods Twenty-four (12 male, 12 female) subjects who had no previous experience with either conventional or digital impression participated in this study. Conventional impressions of maxillary and mandibular dental arches were taken with a polyether impression material (Impregum, 3 M ESPE), and bite registrations were made with polysiloxane bite registration material (Futar D, Kettenbach). Two weeks later, digital impressions and bite scans were performed using an intra-oral scanner (CEREC Omnicam, Sirona). Immediately after the impressions were made, the subjects’ attitudes, preferences and perceptions towards impression techniques were evaluated using a standardized questionnaire. The perceived source of stress was evaluated using the State-Trait Anxiety Scale. Processing steps of the impression techniques (tray selection, working time etc.) were recorded in seconds. Statistical analyses were performed with the Wilcoxon Rank test, and p < 0.05 was considered significant. Results There were significant differences among the groups (p < 0.05) in terms of total working time and processing steps. Patients stated that digital impressions were more comfortable than conventional techniques. Conclusions Digital impressions resulted in a more time-efficient technique than conventional impressions. Patients preferred the digital impression technique rather than conventional techniques. PMID:24479892

  10. Strapdown system performance optimization test evaluations (SPOT), volume 1

    NASA Technical Reports Server (NTRS)

    Blaha, R. J.; Gilmore, J. P.

    1973-01-01

    A three axis inertial system was packaged in an Apollo gimbal fixture for fine grain evaluation of strapdown system performance in dynamic environments. These evaluations have provided information to assess the effectiveness of real-time compensation techniques and to study system performance tradeoffs to factors such as quantization and iteration rate. The strapdown performance and tradeoff studies conducted include: (1) Compensation models and techniques for the inertial instrument first-order error terms were developed and compensation effectivity was demonstrated in four basic environments; single and multi-axis slew, and single and multi-axis oscillatory. (2) The theoretical coning bandwidth for the first-order quaternion algorithm expansion was verified. (3) Gyro loop quantization was identified to affect proportionally the system attitude uncertainty. (4) Land navigation evaluations identified the requirement for accurate initialization alignment in order to pursue fine grain navigation evaluations.

  11. Evaluation outcomes of a sex education strategy in high schools of Pavia (Italy).

    PubMed

    Benni, Emanuela; Sacco, Sara; Bianchi, Leonardo; Carrara, Roberto; Zanini, Chiara; Comelli, Mario; Tenconi, Maria Teresa

    2016-06-01

    We aimed to provide process and effectiveness evaluations of a sex education intervention realized with interactive techniques in high schools of Pavia (Italy). Six public high schools, divided into 'treated' and 'control' units, voluntarily joined this mixed-methods study. Only second-year classes were enrolled: treated adolescents followed a sex education course, performed by trained 'near-peer educators' (undergraduate medical students) with interactive techniques. All adolescents compiled an anonymous effectiveness evaluation questionnaire at baseline (pre-test) and 3 months later (post-test). Sexual knowledge and reported behavioural changes were compared between the two groups through linear mixed-effects models. The process was assessed through a satisfaction questionnaire for treated students, monitoring cards for working group members and cards/diaries for educators. The final sample consisted of 547 treated and 355 control adolescents (mean age = 15.28 ± 0.61 years). Highly significant changes (p < 0.001) from pre-test to post-test, with strong improvements of treated adolescents, were evident for all knowledge items. No significant changes for behavioural items were reported. Process evaluation showed positive results in adolescents' satisfaction, highlighting the need for more youth gathering places. Working group members and educators generally provided positive evaluations, although difficult communication was perceived. The intervention was effective in improving adolescents' sexual knowledge. The present work highlighted that in Italy sex education in adolescence is still neglected: this could encourage misinformation and health-risk behaviour. Young people perceive the need for a serious health-promoting action in which they could play an active role, spreading educational messages with organized interactive methods. © The Author(s) 2015.

  12. Evaluating response shift in training evaluation: comparing the retrospective pretest with an adapted measurement invariance approach in a classroom management training program.

    PubMed

    Piwowar, Valentina; Thiel, Felicitas

    2014-10-01

    Response shift (RS) can threaten the internal validity of pre-post designs. As RS may indicate a redefinition of the target construct, its occurrence in training evaluation is rather likely. The most common approach to deal with RS is to implement a retrospective pretest (then-test) instead of the traditional pre-test. In health psychology, an adapted measurement invariance approach (MIad) was developed as an alternative technique to study RS. Results produced by identifying RS with the two approaches were rarely studied simultaneously or within an experimental framework. To study RS in two different treatment conditions and compare results produced by both techniques in identifying various types of RS. We further studied validity aspects of the then-test. We evaluated RS by applying the then-test procedure (TP) and the measurement invariance apporach MIad within an experimental design: Participants either attended a short-term or a long-term classroom management training program. Participants were 146 student teachers in their first year of master's study. Pre (before training), post, and then self-ratings (after training) on classroom management knowledge were administered. Results indicated that the two approaches do not yield the same results. The MIad identified more and also group-specific RS as opposed to the findings of the TP, which found less and only little evidence for group-specific RS. Further research is needed to study the usability and validity of the respective approaches. In particular, the usability of the then-test seems to be challenged. © The Author(s) 2014.

  13. Advanced biosensing methodologies developed for evaluating performance quality and safety of emerging biophotonics technologies and medical devices (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Ilev, Ilko K.; Walker, Bennett; Calhoun, William; Hassan, Moinuddin

    2016-03-01

    Biophotonics is an emerging field in modern biomedical technology that has opened up new horizons for transfer of state-of-the-art techniques from the areas of lasers, fiber optics and biomedical optics to the life sciences and medicine. This field continues to vastly expand with advanced developments across the entire spectrum of biomedical applications ranging from fundamental "bench" laboratory studies to clinical patient "bedside" diagnostics and therapeutics. However, in order to translate these technologies to clinical device applications, the scientific and industrial community, and FDA are facing the requirement for a thorough evaluation and review of laser radiation safety and efficacy concerns. In many cases, however, the review process is complicated due the lack of effective means and standard test methods to precisely analyze safety and effectiveness of some of the newly developed biophotonics techniques and devices. There is, therefore, an immediate public health need for new test protocols, guidance documents and standard test methods to precisely evaluate fundamental characteristics, performance quality and safety of these technologies and devices. Here, we will overview our recent developments of novel test methodologies for safety and efficacy evaluation of some emerging biophotonics technologies and medical devices. These methodologies are based on integrating the advanced features of state-of-the-art optical sensor technologies and approaches such as high-resolution fiber-optic sensing, confocal and optical coherence tomography imaging, and infrared spectroscopy. The presentation will also illustrate some methodologies developed and implemented for testing intraocular lens implants, biochemical contaminations of medical devices, ultrahigh-resolution nanoscopy, and femtosecond laser therapeutics.

  14. Crack classification in concrete beams using AE parameters

    NASA Astrophysics Data System (ADS)

    Bahari, N. A. A. S.; Shahidan, S.; Abdullah, S. R.; Ali, N.; Zuki, S. S. Mohd; Ibrahim, M. H. W.; Rahim, M. A.

    2017-11-01

    The acoustic emission (AE) technique is an effective tool for the evaluation of crack growth. The aim of this study is to evaluate crack classification in reinforced concrete beams using statistical analysis. AE has been applied for the early monitoring of reinforced concrete structures using AE parameters such as average frequency, rise time, amplitude counts and duration. This experimental study focuses on the utilisation of this method in evaluating reinforced concrete beams. Beam specimens measuring 150 mm × 250 mm × 1200 mm were tested using a three-point load flexural test using Universal Testing Machines (UTM) together with an AE monitoring system. The results indicated that RA value can be used to determine the relationship between tensile crack and shear movement in reinforced concrete beams.

  15. Evaluation of a 40 to 1 scale model of a low pressure engine

    NASA Technical Reports Server (NTRS)

    Cooper, C. E., Jr.; Thoenes, J.

    1972-01-01

    An evaluation of a scale model of a low pressure rocket engine which is used for secondary injection studies was conducted. Specific objectives of the evaluation were to: (1) assess the test conditions required for full scale simulations; (2) recommend fluids to be used for both primary and secondary flows; and (3) recommend possible modifications to be made to the scale model and its test facility to achieve the highest possible degree of simulation. A discussion of the theoretical and empirical scaling laws which must be observed to apply scale model test data to full scale systems is included. A technique by which the side forces due to secondary injection can be analytically estimated is presented.

  16. Development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements

    NASA Technical Reports Server (NTRS)

    Rey, Charles A.

    1991-01-01

    The development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements are discussed. Efforts were directed towards the following task areas: design and development of a High Temperature Acoustic Levitator (HAL) for containerless processing and property measurements at high temperatures; testing of the HAL module to establish this technology for use as a positioning device for microgravity uses; construction and evaluation of a brassboard hot wall Acoustic Levitation Furnace; construction and evaluation of a noncontact temperature measurement (NCTM) system based on AGEMA thermal imaging camera; construction of a prototype Division of Amplitude Polarimetric Pyrometer for NCTM of levitated specimens; evaluation of and recommendations for techniques to control contamination in containerless materials processing chambers; and evaluation of techniques for heating specimens to high temperatures for containerless materials experimentation.

  17. Development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements

    NASA Astrophysics Data System (ADS)

    Rey, Charles A.

    1991-03-01

    The development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements are discussed. Efforts were directed towards the following task areas: design and development of a High Temperature Acoustic Levitator (HAL) for containerless processing and property measurements at high temperatures; testing of the HAL module to establish this technology for use as a positioning device for microgravity uses; construction and evaluation of a brassboard hot wall Acoustic Levitation Furnace; construction and evaluation of a noncontact temperature measurement (NCTM) system based on AGEMA thermal imaging camera; construction of a prototype Division of Amplitude Polarimetric Pyrometer for NCTM of levitated specimens; evaluation of and recommendations for techniques to control contamination in containerless materials processing chambers; and evaluation of techniques for heating specimens to high temperatures for containerless materials experimentation.

  18. Characterization of Nitinol Laser-Weld Joints by Nondestructive Testing

    NASA Astrophysics Data System (ADS)

    Wohlschlögel, Markus; Gläßel, Gunter; Sanchez, Daniela; Schüßler, Andreas; Dillenz, Alexander; Saal, David; Mayr, Peter

    2015-12-01

    Joining technology is an integral part of today's Nitinol medical device manufacturing. Besides crimping and riveting, laser welding is often applied to join components made from Nitinol to Nitinol, as well as Nitinol components to dissimilar materials. Other Nitinol joining techniques include adhesive bonding, soldering, and brazing. Typically, the performance of joints is assessed by destructive mechanical testing, on a process validation base. In this study, a nondestructive testing method—photothermal radiometry—is applied to characterize small Nitinol laser-weld joints used to connect two wire ends via a sleeve. Two different wire diameters are investigated. Effective joint connection cross sections are visualized using metallography techniques. Results of the nondestructive testing are correlated to data from destructive torsion testing, where the maximum torque at fracture is evaluated for the same joints and criteria for the differentiation of good and poor laser-welding quality by nondestructive testing are established.

  19. A quantitative investigation of the fracture pump-in/flowback test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plahn, S.V.; Nolte, K.G.; Miska, S.

    1995-12-31

    Fracture closure pressure is an important parameter for fracture treatment design and evaluation. The pump-in/flowback (PIFB) test is frequently used to estimate its magnitude. The test is attractive because bottomhole pressures during flowback develop a distinct and repeatable signature. This is in contrast to the pump-in/shut-in test where strong indications of fracture closure are rarely seen. Various techniques exist for extracting closure pressure from the flowback pressure response. Unfortunately, these procedures give different estimates for closure pressure and their theoretical bases are not well established. We present results that place the PIFB test on a more solid foundation. A numericalmore » model is used to simulate the PIFB test and glean physical mechanisms contributing to the response. Based on our simulation results, we propose an interpretation procedure which gives better estimates for closure pressure than existing techniques.« less

  20. Application of nomographs for analysis and prediction of receiver spurious response EMI

    NASA Astrophysics Data System (ADS)

    Heather, F. W.

    1985-07-01

    Spurious response EMI for the front end of a superheterodyne receiver follows a simple mathematic formula; however, the application of the formula to predict test frequencies produces more data than can be evaluated. An analysis technique has been developed to graphically depict all receiver spurious responses usig a nomograph and to permit selection of optimum test frequencies. The discussion includes the math model used to simulate a superheterodyne receiver, the implementation of the model in the computer program, the approach to test frequency selection, interpretation of the nomographs, analysis and prediction of receiver spurious response EMI from the nomographs, and application of the nomographs. In addition, figures are provided of sample applications. This EMI analysis and prediction technique greatly improves the Electromagnetic Compatibility (EMC) test engineer's ability to visualize the scope of receiver spurious response EMI testing and optimize test frequency selection.

  1. Stress corrosion evaluation of powder metallurgy aluminum alloy 7091 with the breaking load test method

    NASA Technical Reports Server (NTRS)

    Domack, Marcia S.

    1987-01-01

    The stress corrosion behavior of the P/M aluminum alloy 7091 is evaluated in two overaged heat treatment conditions, T7E69 and T7E70, using an accelerated test technique known as the breaking load test method. The breaking load data obtained in this study indicate that P/M 7091 alloy is highly resistant to stress corrosion in both longitudinal and transverse orientations at stress levels up to 90 percent of the material yield strength. The reduction in mean breaking stress as a result of corrosive attack is smallest for the more overaged T7E70 condition. Details of the test procedure are included.

  2. Develop advanced nonlinear signal analysis topographical mapping system

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The Space Shuttle Main Engine (SSME) has been undergoing extensive flight certification and developmental testing, which involves some 250 health monitoring measurements. Under the severe temperature, pressure, and dynamic environments sustained during operation, numerous major component failures have occurred, resulting in extensive engine hardware damage and scheduling losses. To enhance SSME safety and reliability, detailed analysis and evaluation of the measurements signal are mandatory to assess its dynamic characteristics and operational condition. Efficient and reliable signal detection techniques will reduce catastrophic system failure risks and expedite the evaluation of both flight and ground test data, and thereby reduce launch turn-around time. The basic objective of this contract are threefold: (1) develop and validate a hierarchy of innovative signal analysis techniques for nonlinear and nonstationary time-frequency analysis. Performance evaluation will be carried out through detailed analysis of extensive SSME static firing and flight data. These techniques will be incorporated into a fully automated system; (2) develop an advanced nonlinear signal analysis topographical mapping system (ATMS) to generate a Compressed SSME TOPO Data Base (CSTDB). This ATMS system will convert tremendous amount of complex vibration signals from the entire SSME test history into a bank of succinct image-like patterns while retaining all respective phase information. High compression ratio can be achieved to allow minimal storage requirement, while providing fast signature retrieval, pattern comparison, and identification capabilities; and (3) integrate the nonlinear correlation techniques into the CSTDB data base with compatible TOPO input data format. Such integrated ATMS system will provide the large test archives necessary for quick signature comparison. This study will provide timely assessment of SSME component operational status, identify probable causes of malfunction, and indicate feasible engineering solutions. The final result of this program will yield an ATMS system of nonlinear and nonstationary spectral analysis software package integrated with the Compressed SSME TOPO Data Base (CSTDB) on the same platform. This system will allow NASA engineers to retrieve any unique defect signatures and trends associated with different failure modes and anomalous phenomena over the entire SSME test history across turbo pump families.

  3. Develop advanced nonlinear signal analysis topographical mapping system

    NASA Technical Reports Server (NTRS)

    Jong, Jen-Yi

    1993-01-01

    The SSME has been undergoing extensive flight certification and developmental testing, which involves some 250 health monitoring measurements. Under the severe temperature pressure, and dynamic environments sustained during operation, numerous major component failures have occurred, resulting in extensive engine hardware damage and scheduling losses. To enhance SSME safety and reliability, detailed analysis and evaluation of the measurements signal are mandatory to assess its dynamic characteristics and operational condition. Efficient and reliable signal detection techniques will reduce catastrophic system failure risks and expedite the evaluation of both flight and ground test data, and thereby reduce launch turn-around time. The basic objective of this contract are threefold: (1) Develop and validate a hierarchy of innovative signal analysis techniques for nonlinear and nonstationary time-frequency analysis. Performance evaluation will be carried out through detailed analysis of extensive SSME static firing and flight data. These techniques will be incorporated into a fully automated system. (2) Develop an advanced nonlinear signal analysis topographical mapping system (ATMS) to generate a Compressed SSME TOPO Data Base (CSTDB). This ATMS system will convert tremendous amounts of complex vibration signals from the entire SSME test history into a bank of succinct image-like patterns while retaining all respective phase information. A high compression ratio can be achieved to allow the minimal storage requirement, while providing fast signature retrieval, pattern comparison, and identification capabilities. (3) Integrate the nonlinear correlation techniques into the CSTDB data base with compatible TOPO input data format. Such integrated ATMS system will provide the large test archives necessary for a quick signature comparison. This study will provide timely assessment of SSME component operational status, identify probable causes of malfunction, and indicate feasible engineering solutions. The final result of this program will yield an ATMS system of nonlinear and nonstationary spectral analysis software package integrated with the Compressed SSME TOPO Data Base (CSTDB) on the same platform. This system will allow NASA engineers to retrieve any unique defect signatures and trends associated with different failure modes and anomalous phenomena over the entire SSME test history across turbo pump families.

  4. Remote Leak Detection: Indirect Thermal Technique

    NASA Technical Reports Server (NTRS)

    Clements, Sandra

    2002-01-01

    Remote sensing technologies are being considered for efficient, low cost gas leak detection. Eleven specific techniques have been identified for further study and evaluation of several of these is underway. The Indirect Thermal Technique is one of the techniques that is being explored. For this technique, an infrared camera is used to detect the temperature change of a pipe or fitting at the site of a gas leak. This temperature change is caused by the change in temperature of the gas expanding from the leak site. During the 10-week NFFP program, the theory behind the technique was further developed, experiments were performed to determine the conditions for which the technique might be viable, and a proof-of-concept system was developed and tested in the laboratory.

  5. Biomechanical evaluation of different suture techniques for arthroscopic transtibial pull-out repair of posterior medial meniscus root tears.

    PubMed

    Feucht, Matthias J; Grande, Eduardo; Brunhuber, Johannes; Burgkart, Rainer; Imhoff, Andreas B; Braun, Sepp

    2013-12-01

    A tear of the posterior medial meniscus root (PMMR) is increasingly recognized as a serious knee joint injury. Several suture techniques for arthroscopic transtibial pull-out repair have been described; however, only limited data about the biomechanical properties of these techniques are currently available. There are significant differences between the tested suture techniques, with more complex suture configurations providing superior biomechanical properties. Controlled laboratory study. A total of 40 porcine medial menisci were randomly assigned to 1 of 4 groups (10 specimens each) according to suture technique: two simple stitches (TSS), horizontal mattress suture (HMS), modified Mason-Allen suture (MMA), and two modified loop stitches (TLS). Meniscus-suture constructs were subjected to cyclic loading followed by load-to-failure testing in a servohydraulic material testing machine. During cyclic loading, the HMS and TLS groups showed a significantly higher displacement after 100, 500, and 1000 cycles compared with the TSS and MMA groups. After 1000 cycles, the highest displacement was found for the TLS group, with significant differences compared with all other groups. During load-to-failure testing, the highest maximum load and yield load were observed for the MMA group, with statistically significant differences compared with the TSS and TLS groups. With regard to stiffness, the TSS and MMA groups showed significantly higher values compared with the HMS and TLS groups. The MMA technique provided the best biomechanical properties with regard to cyclic loading and load-to-failure testing. The TSS technique seems to be a valuable alternative. Both the HMS and TLS techniques have the disadvantage of lower stiffness and higher displacement during cyclic loading. Using a MMA technique may improve healing rates and avoid progressive extrusion of the medial meniscus after transtibial pull-out repair of PMMR tears. The TSS technique may be used as an alternative that is easier to perform, but a more careful rehabilitation program is possibly necessary to avoid early failure.

  6. Advection of sulfur dioxide over the western Atlantic Ocean during CITE 3

    NASA Technical Reports Server (NTRS)

    Thornton, D. C.; Bandy, A. R.; Beltz, N.; Driedger, A. R., III; Ferek, R.

    1993-01-01

    During the NASA Chemical Instrumentation Test and Evaluation 3 sulfur intercomparison over the western Atlantic Ocean, five techniques for the determination of sulfur dioxide were evaluated. The response times of the techniques varied from 3 to 30 min. Based on the ensemble of measurements reported, it was clear that advection of SO2 from the North American continent occurred in the boundary layer (altitude less than 1 km) with only one exception. The vertical distribution of SO2 above the boundary layer for the northern and southern Atlantic Ocean was remarkably similar duing this experiment.

  7. Applying usability testing techniques to improve a health promotion website.

    PubMed

    Hinchliffe, Anetta; Mummery, W Kerry

    2008-04-01

    Use of the Internet for health promotion is increasing; however, the lack of published research regarding website usability suggests that health promotion websites are being developed without consultation with their users or formal evaluation. This study conducted usability testing of an existing health promotion website to inform modifications and to identify common usability themes that should be addressed by organisations developing or maintaining a health promotion website. A combination of qualitative and quantitative techniques were implemented during the usability testing sessions to gather data from users while completing tasks on the website. Techniques included performance measures (time taken), direct observation (participant observation) and subjective user preferences (questionnaire and interview). Improvements to the website were measured in terms of reduced problems reported, reduced time taken to complete tasks and increased subjective reports. Seven usability themes emerged from the data: design, feedback, format, instructions, navigation, terminology and learnability. This study demonstrates the application of usability testing to the design and modification of a health promotion website and illustrates the areas or themes that can be used as a framework for testing and modification.

  8. DRUG EVALUATION AND DECISION MAKING IN CATALONIA: DEVELOPMENT AND VALIDATION OF A METHODOLOGICAL FRAMEWORK BASED ON MULTI-CRITERIA DECISION ANALYSIS (MCDA) FOR ORPHAN DRUGS.

    PubMed

    Gilabert-Perramon, Antoni; Torrent-Farnell, Josep; Catalan, Arancha; Prat, Alba; Fontanet, Manel; Puig-Peiró, Ruth; Merino-Montero, Sandra; Khoury, Hanane; Goetghebeur, Mireille M; Badia, Xavier

    2017-01-01

    The aim of this study was to adapt and assess the value of a Multi-Criteria Decision Analysis (MCDA) framework (EVIDEM) for the evaluation of Orphan drugs in Catalonia (Catalan Health Service). The standard evaluation and decision-making procedures of CatSalut were compared with the EVIDEM methodology and contents. The EVIDEM framework was adapted to the Catalan context, focusing on the evaluation of Orphan drugs (PASFTAC program), during a Workshop with sixteen PASFTAC members. The criteria weighting was done using two different techniques (nonhierarchical and hierarchical). Reliability was assessed by re-test. The EVIDEM framework and methodology was found useful and feasible for Orphan drugs evaluation and decision making in Catalonia. All the criteria considered for the development of the CatSalut Technical Reports and decision making were considered in the framework. Nevertheless, the framework could improve the reporting of some of these criteria (i.e., "unmet needs" or "nonmedical costs"). Some Contextual criteria were removed (i.e., "Mandate and scope of healthcare system", "Environmental impact") or adapted ("population priorities and access") for CatSalut purposes. Independently of the weighting technique considered, the most important evaluation criteria identified for orphan drugs were: "disease severity", "unmet needs" and "comparative effectiveness", while the "size of the population" had the lowest relevance for decision making. Test-retest analysis showed weight consistency among techniques, supporting reliability overtime. MCDA (EVIDEM framework) could be a useful tool to complement the current evaluation methods of CatSalut, contributing to standardization and pragmatism, providing a method to tackle ethical dilemmas and facilitating discussions related to decision making.

  9. Towards standardized testing methodologies for optical properties of components in concentrating solar thermal power plants

    NASA Astrophysics Data System (ADS)

    Sallaberry, Fabienne; Fernández-García, Aránzazu; Lüpfert, Eckhard; Morales, Angel; Vicente, Gema San; Sutter, Florian

    2017-06-01

    Precise knowledge of the optical properties of the components used in the solar field of concentrating solar thermal power plants is primordial to ensure their optimum power production. Those properties are measured and evaluated by different techniques and equipment, in laboratory conditions and/or in the field. Standards for such measurements and international consensus for the appropriate techniques are in preparation. The reference materials used as a standard for the calibration of the equipment are under discussion. This paper summarizes current testing methodologies and guidelines for the characterization of optical properties of solar mirrors and absorbers.

  10. An in vitro evaluation of rigid internal fixation techniques for sagittal split ramus osteotomies: setback surgery.

    PubMed

    Brasileiro, Bernardo Ferreira; Grotta-Grempel, Rafael; Ambrosano, Glaucia Maria Bovi; Passeri, Luis Augusto

    2012-04-01

    The aim of this study was to evaluate the biomechanical features of 3 different methods of rigid internal fixation for sagittal split ramus osteotomy for mandibular setback in vitro. Sixty polyurethane replicas of human hemimandibles were used as substrates, simulating a 5-mm setback surgery by sagittal split ramus osteotomy. These replicas served to reproduce 3 different techniques of fixation, including 1) a 4-hole plate and 4 monocortical screws (miniplate group), 2) a 4-hole plate and 4 monocortical screws with 1 additional bicortical positional screw (hybrid group), and 3) 3 bicortical positional screws in a traditional inverted-L pattern (inverted-L group). After fixation, hemimandibles were adapted to a test support and subjected to lateral torsional forces on the buccal molar surface and vertical cantilever loading on the incisal edge with an Instron 4411 mechanical testing unit. Peak loadings at 1, 3, 5, and 10 mm of displacement were recorded. Means and standard deviation were analyzed using analysis of variance and Tukey test with a 5% level of significance, and failures during tests were recorded. Regardless of the amount of displacement and direction of force, the miniplate group always showed the lowest load peak scores (P < .01) compared with the other fixation techniques. The hybrid group demonstrated behavior similar to the inverted-L group in lateral and vertical forces at any loading displacement (P > .05). Molar load tests required more force than incisal load tests to promote the same displacement in the mandibular setback model (P < .05). For mandibular setback surgery of 5 mm, this study concluded that the fixation technique based on the miniplate group was significantly less rigid than the fixation observed in the hybrid and inverted-L groups. Mechanically, adding 1 bicortical positional screw in the retromolar region in the miniplate technique may achieve the same stabilization offered by inverted-L fixation for mandibular sagittal split ramus osteotomy setback surgery in vitro. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Aircraft propeller induced structure-borne noise

    NASA Technical Reports Server (NTRS)

    Unruh, James F.

    1989-01-01

    A laboratory-based test apparatus employing components typical of aircraft construction was developed that would allow the study of structure-borne noise transmission due to propeller induced wake/vortex excitation of in-wake structural appendages. The test apparatus was employed to evaluate several aircraft installation effects (power plant placement, engine/nacelle mass loading, and wing/fuselage attachment methods) and several structural response modifications for structure-borne noise control (the use of wing blocking mass/fuel, wing damping treaments, and tuned mechanical dampers). Most important was the development of in-flight structure-borne noise transmission detection techniques using a combination of ground-based frequency response function testing and in-flight structural response measurement. Propeller wake/vortex excitation simulation techniques for improved ground-based testing were also developed to support the in-flight structure-borne noise transmission detection development.

  12. Image dissector photocathode solar damage test program. [solar radiation shielding using a fast optical lens

    NASA Technical Reports Server (NTRS)

    Smith, R. A.

    1977-01-01

    Image dissector sensors of the same type which will be used in the NASA shuttle star tracker were used in a series of tests directed towards obtaining solar radiation/time damage criteria. Data were evaluated to determine the predicted level of operability of the star tracker if tube damage became a reality. During the test series a technique for reducing the solar damage effect was conceived and verified. The damage concepts are outlined and the test methods and data obtained which were used for verification of the technique's feasibility are presented. The ability to operate an image dissector sensor with the solar image focussed on the photocathode by a fast optical lens under certain conditions is feasible and the elimination of a mechanical protection device is possible.

  13. Active member vibration control for a 4 meter primary reflector support structure

    NASA Technical Reports Server (NTRS)

    Umland, J. W.; Chen, G.-S.

    1992-01-01

    The design and testing of a new low voltage piezoelectric active member with integrated load cell and displacement sensor is described. This active member is intended for micron level vibration and structural shape control of the Precision Segmented Reflector test-bed. The test-bed is an erectable 4 meter diameter backup support truss for a 2.4 meter focal length parabolic reflector. Active damping of the test-bed is then demonstrated using the newly developed active members. The control technique used is referred to as bridge feedback. With this technique the internal sensors are used in a local feedback loop to match the active member's input impedance to the structure's load impedance, which then maximizes vibrational energy dissipation. The active damping effectiveness is then evaluated from closed loop frequency responses.

  14. Development of flexural vibration inspection techniques to rapidly assess the structural health of timber bridge systems

    Treesearch

    Xiping Wang; James P. Wacker; Robert J. Ross; Brian K. Brashaw; Robert Vatalaro

    2005-01-01

    This paper describes an effort to develop a global dynamic testing technique for evaluating the overall stiffness of timber bridge superstructures. A forced vibration method was used to measure the natural frequency of single-span timber bridges in the laboratory and field. An analytical model based on simple beam theory was proposed to represent the relationship...

  15. A study for development of aerothermodynamic test model materials and fabrication technique

    NASA Technical Reports Server (NTRS)

    Dean, W. G.; Connor, L. E.

    1972-01-01

    A literature survey, materials reformulation and tailoring, fabrication problems, and materials selection and evaluation for fabricating models to be used with the phase-change technique for obtaining quantitative aerodynamic heat transfer data are presented. The study resulted in the selection of two best materials, stycast 2762 FT, and an alumina ceramic. Characteristics of these materials and detailed fabrication methods are presented.

  16. A new reference tip-timing test bench and simulator for blade synchronous and asynchronous vibrations

    NASA Astrophysics Data System (ADS)

    Hajnayeb, Ali; Nikpour, Masood; Moradi, Shapour; Rossi, Gianluca

    2018-02-01

    The blade tip-timing (BTT) measurement technique is at present the most promising technique for monitoring the blades of axial turbines and aircraft engines in operating conditions. It is generally used as an alternative to strain gauges in turbine testing. By conducting a comparison with the standard methods such as those based on strain gauges, one determines that the technique is not intrusive and does not require a complicated installation process. Despite its superiority to other methods, the experimental performance analysis of a new BTT method needs a test stand that includes a reference measurement system (e.g. strain gauges equipped with telemetry or other complex optical measurement systems, like rotating laser Doppler vibrometers). In this article, a new reliable, low-cost BTT test setup is proposed for simulating and analyzing blade vibrations based on kinematic inversion. In the proposed test bench, instead of the blades vibrating, it is the BTT sensor that vibrates. The vibration of the sensor is generated by a shaker and can therefore be easily controlled in terms of frequency, amplitude and waveform shape. The amplitude of vibration excitation is measured by a simple accelerometer. After introducing the components of the simulator, the proposed test bench is used in practice to simulate both synchronous and asynchronous vibration scenarios. Then two BTT methods are used to evaluate the quality of the acquired data. The results demonstrate that the proposed setup is able to generate simulated pulse sequences which are almost the same as those generated by the conventional BTT systems installed around a bladed disk. Moreover, the test setup enables its users to evaluate BTT methods by using a limited number of sensors. This significantly reduces the total costs of the experiments.

  17. Comparison of the efficacy of a custom-made pulse oximeter probe with digital electric pulp tester, cold spray, and rubber cup for assessing pulp vitality.

    PubMed

    Dastmalchi, Nafiseh; Jafarzadeh, Hamid; Moradi, Saeed

    2012-09-01

    The ideal technique for the evaluation of pulp vitality should be noninvasive, painless, objective, reliable, and reproducible. To achieve this, the most routine tests are sensitivity tests. However, a major shortcoming with these tests is that they indirectly indicate pulp vitality by measuring a neural response. Pulse oximetry is a well-established oxygen saturation monitoring technique broadly used in medicine. However, its efficacy as the pulp vitality test should be evaluated. The aim of this study was to design and build a custom-made pulse oximeter dental probe and to evaluate its efficacy in comparison with electric pulp tester, cold spray, and a rubber cup in pulp vitality testing. Twenty-four single-canal mandibular premolars needing endodontic treatment were selected. The patients did not have systemic disease and did not consume drugs. Also, they had no clinically relevant signs of necrosis. The selected teeth were pulpally tested with 4 kinds of tests including pulse oximetry, the electric test, cold spray, and the rubber cup. After endodontic treatment of these teeth, which revealed the actual status of the pulp, the results were analyzed by the kappa test to show the efficacy of these tests. When comparing electric, cold, heat, and pulse oximeter tests with the gold standard, the kappa agreement coefficient was 18%, 18%, 14%, and 91%, respectively. The sensitivity of pulse oximetry, a rubber cup, electric test, and cold spray was 0.93, 0.60, 0.60, and 0.53, respectively. The specificity of these tests was 1.00, 0.55, 0.22, and 0.66, respectively. Pulp testing by using pulse oximetry is more reliable than the electric test, rubber cup, and cold spray. The custom-made pulse oximeter dental probe is an effective and objective method for pulp vitality assessment. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  18. Shearography for Non-Destructive Evaluation with Applications to BAT Mask Tile Adhesive Bonding and Specular Surface Honeycomb Panels

    NASA Technical Reports Server (NTRS)

    Lysak, Daniel B.

    2003-01-01

    In this report we examine the applicability of shearography techniques for nondestructive inspection and evaluation in two unique application areas. In the first application, shearography is used to evaluate the quality of adhesive bonds holding lead tiles to the BAT gamma ray mask for the NASA Swift program. By exciting the mask with a vibration, the more poorly bonded tiles can be distinguished by their greater displacement response, which is readily identifiable in the shearography image. A quantitative analysis is presented that compares the shearography results with a destructive pull test measuring the force at bond failure. Generally speaking, the results show good agreement. Further investigation would be useful to optimize certain test parameters such as vibration frequency and amplitude. The second application is to evaluate the bonding between the skin and core of a honeycomb structure with a specular (mirror-like) surface. In standard shearography techniques, the object under test must have a diffuse surface to generate the speckle patterns in laser light, which are then sheared. A novel configuration using the specular surface as a mirror to image speckles from a diffuser is presented, opening up the use of shearography to a new class of objects that could not have been examined with the traditional approach. This new technique readily identifies large scale bond failures in the panel, demonstrating the validity of this approach. For the particular panel examined here, some scaling issues should be examined further to resolve the measurement scale down to the very small size of the core cells. In addition, further development should be undertaken to determine the general applicability of the new approach and to establish a firm quantitative foundation.

  19. In vitro biomechanical comparison of multistrand cables with conventional cervical stabilization.

    PubMed

    Weis, J C; Cunningham, B W; Kanayama, M; Parker, L; McAfee, P C

    1996-09-15

    The biomechanical stability of six different methods of cervical spine stabilization, three using multistrand cables, were evaluated in a bovine model. To quantify and compare the in vitro biomechanical properties of multistrand cables used for posterior cervical wiring to standard cervical fixation techniques. Fixation of the posterior cervical spine with monofilament stainless steel wire is a proven technique for stabilization of the cervical spine. Recently, multistrand braided cables have been used as a substitute for monofilament stainless steel wires. These cables, made of stainless steel, titanium, or polyethylene, are reported to be stronger, more flexible, and fatigue resistant than are monofilament wire based on mechanical testing. However, no in vitro biomechanical studies have been performed testing a standard posterior cervical wiring technique using multistrand cables. Thirty-six fresh frozen cervical calf spines consistent in size and age were mounted and fixed rigidly to isolate the C4-C5 motion segment. Six different reconstruction techniques were evaluated for Rogers' posterior cervical wiring technique using: 1) 20-gauge stainless steel monofilament wire, 2) stainless steel cable, 3) titanium cable, 4) polyethylene cables, 5) anterior locking plate construct with interbody graft, and 6) posterior plate construct. Six cervical spines were included in each group (n = 6), with each specimen statically evaluated under three stability conditions: 1) intact, 2) reconstructed, and 3) postfatigue. The instability model created before the reconstruction consisted of a distractive flexion Stage 3 injury at C4-C5. Nondestructive static biomechanical testing, performed on an material testing machine (MTS 858 Bionix test system, Minneapolis, MN), included axial compression, axial rotation, flexion-extension, and lateral bending. After reconstruction and static analysis, the specimens were fatigued for 1500 cycles and then statically retested. Data analysis included normalization of the reconstructed and postfatigue data to the intact condition. The calculated static parameters included operative functional unit stiffness and range of motion. Posterior cervical reconstruction with stainless steel monofilament wire proved inadequate under fatigue testing. Two of the six specimens failed with fatigue, and this construct permitted the greatest degree of flexion-extension motion after fatigue in comparison with all other constructs (P < 0.05). There were no significant differences in flexural stiffness or range of motion between stainless steel, titanium, or polyethylene cable constructs before or after fatigue testing. The posterior cervical plate constructs were the stiffest constructs under flexion, extension, and lateral bending modes, before and after fatigue testing (P < 0.05). Multistrand cables were superior to monofilament wire with fatigue testing using an in vitro calf cervical spine model. There were no failures or detectable differences in elongation after fatigue testing between the stainless steel, titanium, and polyethylene cables, as shown by the flexion-extension range of motion. The posterior cervical plate construct offered the greatest stability compared with all other constructs.

  20. Development and Hotfire Testing of Additively Manufactured Copper Combustion Chambers for Liquid Rocket Engine Applications

    NASA Technical Reports Server (NTRS)

    Gradl, Paul R.; Greene, Sandy; Protz, Chris

    2017-01-01

    NASA and industry partners are working towards fabrication process development to reduce costs and schedules associated with manufacturing liquid rocket engine components with the goal of reducing overall mission costs. One such technique being evaluated is powder-bed fusion or selective laser melting (SLM), commonly referred to as additive manufacturing (AM). The NASA Low Cost Upper Stage Propulsion (LCUSP) program was designed to develop processes and material characterization for GRCop-84 (a NASA Glenn Research Center-developed copper, chrome, niobium alloy) commensurate with powder bed AM, evaluate bimetallic deposition, and complete testing of a full scale combustion chamber. As part of this development, the process has been transferred to industry partners to enable a long-term supply chain of monolithic copper combustion chambers. To advance the processes further and allow for optimization with multiple materials, NASA is also investigating the feasibility of bimetallic AM chambers. In addition to the LCUSP program, NASA’s Marshall Space Flight Center (MSFC) has completed a series of development programs and hot-fire tests to demonstrate SLM GRCop-84 and other AM techniques. MSFC’s efforts include a 4,000 pounds-force thrust liquid oxygen/methane (LOX/CH4) combustion chamber. Small thrust chambers for 1,200 pounds-force LOX/hydrogen (H2) applications have also been designed and fabricated with SLM GRCop-84. Similar chambers have also completed development with an Inconel 625 jacket bonded to the GRCop-84 material, evaluating direct metal deposition (DMD) laser- and arc-based techniques. The same technologies for these lower thrust applications are being applied to 25,000-35,000 pounds-force main combustion chamber (MCC) designs. This paper describes the design, development, manufacturing and testing of these numerous combustion chambers, and the associated lessons learned throughout their design and development processes.

Top