Estimation of Initial and Response Times of Laser Dew-Point Hygrometer by Measurement Simulation
NASA Astrophysics Data System (ADS)
Matsumoto, Sigeaki; Toyooka, Satoru
1995-10-01
The initial and the response times of the laser dew-point hygrometer were evaluated by measurement simulation. The simulation was based on loop computations of the surface temperature of a plate with dew deposition, the quantity of dew deposited and the intensity of scattered light from the surface at each short interval of measurement. The initial time was defined as the time necessary for the hygrometer to reach a temperature within ±0.5° C of the measured dew point from the start time of measurement, and the response time was also defined for stepwise dew-point changes of +5° C and -5° C. The simulation results are in approximate agreement with the recorded temperature and intensity of scattered light of the hygrometer. The evaluated initial time ranged from 0.3 min to 5 min in the temperature range from 0° C to 60° C, and the response time was also evaluated to be from 0.2 min to 3 min.
Zhou, Nan; Guo, Tingting; Zheng, Huanhuan; Pan, Xia; Chu, Chen; Dou, Xin; Li, Ming; Liu, Song; Zhu, Lijing; Liu, Baorui; Chen, Weibo; He, Jian; Yan, Jing; Zhou, Zhengyang; Yang, Xiaofeng
2017-01-01
We investigated apparent diffusion coefficient (ADC) histogram analysis to evaluate radiation-induced parotid damage and predict xerostomia degrees in nasopharyngeal carcinoma (NPC) patients receiving radiotherapy. The imaging of bilateral parotid glands in NPC patients was conducted 2 weeks before radiotherapy (time point 1), one month after radiotherapy (time point 2), and four months after radiotherapy (time point 3). From time point 1 to 2, parotid volume, skewness, and kurtosis decreased (P < 0.001, = 0.001, and < 0.001, respectively), but all other ADC histogram parameters increased (all P < 0.001, except P = 0.006 for standard deviation [SD]). From time point 2 to 3, parotid volume continued to decrease (P = 0.022), and SD, 75th and 90th percentiles continued to increase (P = 0.024, 0.010, and 0.006, respectively). Early change rates of parotid ADCmean, ADCmin, kurtosis, and 25th, 50th, 75th, 90th percentiles (from time point 1 to 2) correlated with late parotid atrophy rate (from time point 1 to 3) (all P < 0.05). Multiple linear regression analysis revealed correlations among parotid volume, time point, and ADC histogram parameters. Early mean change rates for bilateral parotid SD and ADCmax could predict late xerostomia degrees at seven months after radiotherapy (three months after time point 3) with AUC of 0.781 and 0.818 (P = 0.014, 0.005, respectively). ADC histogram parameters were reproducible (intraclass correlation coefficient, 0.830 - 0.999). ADC histogram analysis could be used to evaluate radiation-induced parotid damage noninvasively, and predict late xerostomia degrees of NPC patients treated with radiotherapy. PMID:29050274
Zhou, Nan; Guo, Tingting; Zheng, Huanhuan; Pan, Xia; Chu, Chen; Dou, Xin; Li, Ming; Liu, Song; Zhu, Lijing; Liu, Baorui; Chen, Weibo; He, Jian; Yan, Jing; Zhou, Zhengyang; Yang, Xiaofeng
2017-09-19
We investigated apparent diffusion coefficient (ADC) histogram analysis to evaluate radiation-induced parotid damage and predict xerostomia degrees in nasopharyngeal carcinoma (NPC) patients receiving radiotherapy. The imaging of bilateral parotid glands in NPC patients was conducted 2 weeks before radiotherapy (time point 1), one month after radiotherapy (time point 2), and four months after radiotherapy (time point 3). From time point 1 to 2, parotid volume, skewness, and kurtosis decreased ( P < 0.001, = 0.001, and < 0.001, respectively), but all other ADC histogram parameters increased (all P < 0.001, except P = 0.006 for standard deviation [SD]). From time point 2 to 3, parotid volume continued to decrease ( P = 0.022), and SD, 75 th and 90 th percentiles continued to increase ( P = 0.024, 0.010, and 0.006, respectively). Early change rates of parotid ADC mean , ADC min , kurtosis, and 25 th , 50 th , 75 th , 90 th percentiles (from time point 1 to 2) correlated with late parotid atrophy rate (from time point 1 to 3) (all P < 0.05). Multiple linear regression analysis revealed correlations among parotid volume, time point, and ADC histogram parameters. Early mean change rates for bilateral parotid SD and ADC max could predict late xerostomia degrees at seven months after radiotherapy (three months after time point 3) with AUC of 0.781 and 0.818 ( P = 0.014, 0.005, respectively). ADC histogram parameters were reproducible (intraclass correlation coefficient, 0.830 - 0.999). ADC histogram analysis could be used to evaluate radiation-induced parotid damage noninvasively, and predict late xerostomia degrees of NPC patients treated with radiotherapy.
Silveira, Hevely Saray Lima; Simões-Zenari, Marcia; Kulcsar, Marco Aurélio; Cernea, Claudio Roberto; Nemr, Kátia
2017-10-27
The supracricoid partial laryngectomy allows the preservation of laryngeal functions with good local cancer control. To assess laryngeal configuration and voice analysis data following the performance of a combination of two vocal exercises: the prolonged /b/vocal exercise combined with the vowel /e/ using chest and arm pushing with different durations among individuals who have undergone supracricoid laryngectomy. Eleven patients undergoing partial laryngectomy supracricoid with cricohyoidoepiglottopexy (CHEP) were evaluated using voice recording. Four judges performed separately a perceptive-vocal analysis of hearing voices, with random samples. For the analysis of intrajudge reliability, repetitions of 70% of the voices were done. Intraclass correlation coefficient was used to analyze the reliability of the judges. For an analysis of each judge to the comparison between zero time (time point 0), after the first series of exercises (time point 1), after the second series (time point 2), after the third series (time point 3), after the fourth series (time point 4), and after the fifth and final series (time point 5), the Friedman test was used with a significance level of 5%. The data relative to the configuration of the larynx were subjected to a descriptive analysis. In the evaluation, were considered the judge results 1 which have greater reliability. There was an improvement in the general level of vocal, roughness, and breathiness deviations from time point 4 [T4]. The prolonged /b/vocal exercise, combined with the vowel /e/ using chest- and arm-pushing exercises, was associated with an improvement in the overall grade of vocal deviation, roughness, and breathiness starting at minute 4 among patients who had undergone supracricoid laryngectomy with CHEP reconstruction. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Ignjatovic, Anita Rakic; Miljkovic, Branislava; Todorovic, Dejan; Timotijevic, Ivana; Pokrajac, Milena
2011-05-01
Because moclobemide pharmacokinetics vary considerably among individuals, monitoring of plasma concentrations lends insight into its pharmacokinetic behavior and enhances its rational use in clinical practice. The aim of this study was to evaluate whether single concentration-time points could adequately predict moclobemide systemic exposure. Pharmacokinetic data (full 7-point pharmacokinetic profiles), obtained from 21 depressive inpatients receiving moclobemide (150 mg 3 times daily), were randomly split into development (n = 18) and validation (n = 16) sets. Correlations between the single concentration-time points and the area under the concentration-time curve within a 6-hour dosing interval at steady-state (AUC(0-6)) were assessed by linear regression analyses. The predictive performance of single-point sampling strategies was evaluated in the validation set by mean prediction error, mean absolute error, and root mean square error. Plasma concentrations in the absorption phase yielded unsatisfactory predictions of moclobemide AUC(0-6). The best estimation of AUC(0-6) was achieved from concentrations at 4 and 6 hours following dosing. As the most reliable surrogate for moclobemide systemic exposure, concentrations at 4 and 6 hours should be used instead of predose trough concentrations as an indicator of between-patient variability and a guide for dose adjustments in specific clinical situations.
Performance Evaluation of Real-Time Precise Point Positioning Method
NASA Astrophysics Data System (ADS)
Alcay, Salih; Turgut, Muzeyyen
2017-12-01
Post-Processed Precise Point Positioning (PPP) is a well-known zero-difference positioning method which provides accurate and precise results. After the experimental tests, IGS Real Time Service (RTS) officially provided real time orbit and clock products for the GNSS community that allows real-time (RT) PPP applications. Different software packages can be used for RT-PPP. In this study, in order to evaluate the performance of RT-PPP, 3 IGS stations are used. Results, obtained by using BKG Ntrip Client (BNC) Software v2.12, are examined in terms of both accuracy and precision.
NASA Technical Reports Server (NTRS)
Muellerschoen, Ronald J.; Iijima, Byron; Meyer, Robert; Bar-Sever, Yoaz; Accad, Elie
2004-01-01
This paper evaluates the performance of a single-frequency receiver using the 1-Hz differential corrections as provided by NASA's global differential GPS system. While the dual-frequency user has the ability to eliminate the ionosphere error by taking a linear combination of observables, the single-frequency user must remove or calibrate this error by other means. To remove the ionosphere error we take advantage of the fact that the magnitude of the group delay in range observable and the carrier phase advance have the same magnitude but are opposite in sign. A way to calibrate this error is to use a real-time database of grid points computed by JPL's RTI (Real-Time Ionosphere) software. In both cases we evaluate the positional accuracy of a kinematic carrier phase based point positioning method on a global extent.
Evaluation of effects of long term exposure on lethal toxicity with mammals.
Verma, Vibha; Yu, Qiming J; Connell, Des W
2014-02-01
The relationship between exposure time (LT50) and lethal exposure concentration (LC50) has been evaluated over relatively long exposure times using a novel parameter, Normal Life Expectancy (NLT), as a long term toxicity point. The model equation, ln(LT50) = aLC50(ν) + b, where a, b and ν are constants, was evaluated by plotting lnLT50 against LC50 using available toxicity data based on inhalation exposure from 7 species of mammals. With each specific toxicant a single consistent relationship was observed for all mammals with ν always <1. Use of NLT as a long term toxicity point provided a valuable limiting point for long exposure times. With organic compounds, the Kow can be used to calculate the model constants a and v where these are unknown. The model can be used to characterise toxicity to specific mammals and then be extended to estimate toxicity at any exposure time with other mammals. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.
Khare, Rahul; Sala, Guillaume; Kinahan, Paul; Esposito, Giuseppe; Banovac, Filip; Cleary, Kevin; Enquobahrie, Andinet
2013-01-01
Positron emission tomography computed tomography (PET-CT) images are increasingly being used for guidance during percutaneous biopsy. However, due to the physics of image acquisition, PET-CT images are susceptible to problems due to respiratory and cardiac motion, leading to inaccurate tumor localization, shape distortion, and attenuation correction. To address these problems, we present a method for motion correction that relies on respiratory gated CT images aligned using a deformable registration algorithm. In this work, we use two deformable registration algorithms and two optimization approaches for registering the CT images obtained over the respiratory cycle. The two algorithms are the BSpline and the symmetric forces Demons registration. In the first optmization approach, CT images at each time point are registered to a single reference time point. In the second approach, deformation maps are obtained to align each CT time point with its adjacent time point. These deformations are then composed to find the deformation with respect to a reference time point. We evaluate these two algorithms and optimization approaches using respiratory gated CT images obtained from 7 patients. Our results show that overall the BSpline registration algorithm with the reference optimization approach gives the best results.
Method for discovering relationships in data by dynamic quantum clustering
Weinstein, Marvin; Horn, David
2017-05-09
Data clustering is provided according to a dynamical framework based on quantum mechanical time evolution of states corresponding to data points. To expedite computations, we can approximate the time-dependent Hamiltonian formalism by a truncated calculation within a set of Gaussian wave-functions (coherent states) centered around the original points. This allows for analytic evaluation of the time evolution of all such states, opening up the possibility of exploration of relationships among data-points through observation of varying dynamical-distances among points and convergence of points into clusters. This formalism may be further supplemented by preprocessing, such as dimensional reduction through singular value decomposition and/or feature filtering.
Method for discovering relationships in data by dynamic quantum clustering
Weinstein, Marvin; Horn, David
2014-10-28
Data clustering is provided according to a dynamical framework based on quantum mechanical time evolution of states corresponding to data points. To expedite computations, we can approximate the time-dependent Hamiltonian formalism by a truncated calculation within a set of Gaussian wave-functions (coherent states) centered around the original points. This allows for analytic evaluation of the time evolution of all such states, opening up the possibility of exploration of relationships among data-points through observation of varying dynamical-distances among points and convergence of points into clusters. This formalism may be further supplemented by preprocessing, such as dimensional reduction through singular value decomposition and/or feature filtering.
NASA Astrophysics Data System (ADS)
Hadi Sutrisno, Himawan; Kiswanto, Gandjar; Istiyanto, Jos
2017-06-01
The rough machining is aimed at shaping a workpiece towards to its final form. This process takes up a big proportion of the machining time due to the removal of the bulk material which may affect the total machining time. In certain models, the rough machining has limitations especially on certain surfaces such as turbine blade and impeller. CBV evaluation is one of the concepts which is used to detect of areas admissible in the process of machining. While in the previous research, CBV area detection used a pair of normal vectors, in this research, the writer simplified the process to detect CBV area with a slicing line for each point cloud formed. The simulation resulted in three steps used for this method and they are: 1. Triangulation from CAD design models, 2. Development of CC point from the point cloud, 3. The slicing line method which is used to evaluate each point cloud position (under CBV and outer CBV). The result of this evaluation method can be used as a tool for orientation set-up on each CC point position of feasible areas in rough machining.
Grimm, Alexandra; Meyer, Heiko; Nickel, Marcel D; Nittka, Mathias; Raithel, Esther; Chaudry, Oliver; Friedberger, Andreas; Uder, Michael; Kemmler, Wolfgang; Quick, Harald H; Engelke, Klaus
2018-06-01
The purpose of this study is to evaluate and compare 2-point (2pt), 3-point (3pt), and 6-point (6pt) Dixon magnetic resonance imaging (MRI) sequences with flexible echo times (TE) to measure proton density fat fraction (PDFF) within muscles. Two subject groups were recruited (G1: 23 young and healthy men, 31 ± 6 years; G2: 50 elderly men, sarcopenic, 77 ± 5 years). A 3-T MRI system was used to perform Dixon imaging on the left thigh. PDFF was measured with six Dixon prototype sequences: 2pt, 3pt, and 6pt sequences once with optimal TEs (in- and opposed-phase echo times), lower resolution, and higher bandwidth (optTE sequences) and once with higher image resolution (highRes sequences) and shortest possible TE, respectively. Intra-fascia PDFF content was determined. To evaluate the comparability among the sequences, Bland-Altman analysis was performed. The highRes 6pt Dixon sequences served as reference as a high correlation of this sequence to magnetic resonance spectroscopy has been shown before. The PDFF difference between the highRes 6pt Dixon sequence and the optTE 6pt, both 3pt, and the optTE 2pt was low (between 2.2% and 4.4%), however, not to the highRes 2pt Dixon sequence (33%). For the optTE sequences, difference decreased with the number of echoes used. In conclusion, for Dixon sequences with more than two echoes, the fat fraction measurement was reliable with arbitrary echo times, while for 2pt Dixon sequences, it was reliable with dedicated in- and opposed-phase echo timing. Copyright © 2018 Elsevier B.V. All rights reserved.
Barak-Shinar, Deganit; Green, Lawrence J
2018-01-01
Objective: The aim of this study was to evaluate the safety and efficacy of an herbal and zinc pyrithione shampoo and a scalp lotion (Kamedis Derma-Scalp Dandruff Therapy, Kamedis Ltd., Tel Aviv, Israel) for the treatment of scalp seborrheic dermatitis and dandruff. Design: This was an interventional, open-label, safety and efficacy study. Setting: This open-label study was conducted at Consumer Product Testing Company Inc. in Fairfield, New Jersey. At the baseline visit (Day 0), an examination of the scalp was conducted by a board-certified dermatologist. The entire scalp was evaluated for evidence of seborrheic dermatitis using the Adherent Scalp Flaking Score with a 10-point scale. Only subjects with evidence of moderate-to-greater seborrheic dermatitis or moderate-to-greater dandruff were deemed qualified for inclusion in the study. Participants: Fifty subjects were recruited and included in the study. Measurements: Study subjects were evaluated by the same dermatologist for erythema and flaking at Days 0, 14, 28, and 42 using a five-point scale for each parameter. At each time point, a total severity score was calculated based on the findings of the evaluations. Following the scalp evaluation, each subject had a standardized digital photograph taken of his or her scalp. Each subject was also asked to answer a satisfaction questionnaire regarding the product treatment enhancement and characteristics. Results: A reduction in both parameters evaluated was seen at all time points. Statistical significance was achieved at each time point when compared with the baseline visit. In addition, the subjects expressed a high degree of satisfaction with the treatment. No adverse events were reported during this study. Conclusion: The study showed that the herbal zinc pyrithione shampoo and scalp lotion provided improvement in the main symptoms of seborrheic dermatitis.
Dai, James Y.; Hughes, James P.
2012-01-01
The meta-analytic approach to evaluating surrogate end points assesses the predictiveness of treatment effect on the surrogate toward treatment effect on the clinical end point based on multiple clinical trials. Definition and estimation of the correlation of treatment effects were developed in linear mixed models and later extended to binary or failure time outcomes on a case-by-case basis. In a general regression setting that covers nonnormal outcomes, we discuss in this paper several metrics that are useful in the meta-analytic evaluation of surrogacy. We propose a unified 3-step procedure to assess these metrics in settings with binary end points, time-to-event outcomes, or repeated measures. First, the joint distribution of estimated treatment effects is ascertained by an estimating equation approach; second, the restricted maximum likelihood method is used to estimate the means and the variance components of the random treatment effects; finally, confidence intervals are constructed by a parametric bootstrap procedure. The proposed method is evaluated by simulations and applications to 2 clinical trials. PMID:22394448
Attention and Recall of Point-of-sale Tobacco Marketing: A Mobile Eye-Tracking Pilot Study.
Bansal-Travers, Maansi; Adkison, Sarah E; O'Connor, Richard J; Thrasher, James F
2016-01-01
As tobacco advertising restrictions have increased, the retail 'power wall' behind the counter is increasingly invaluable for marketing tobacco products. The primary objectives of this pilot study were 3-fold: (1) evaluate the attention paid/fixations on the area behind the cash register where tobacco advertising is concentrated and tobacco products are displayed in a real-world setting, (2) evaluate the duration (dwell-time) of these fixations, and (3) evaluate the recall of advertising displayed on the tobacco power wall. Data from 13 Smokers (S) and 12 Susceptible or non-daily Smokers (SS) aged 180-30 from a mobile eye-tracking study. Mobile-eye tracking technology records the orientation (fixation) and duration (dwell-time) of visual attention. Participants were randomized to one of three purchase tasks at a convenience store: Candy bar Only (CO; N = 10), Candy bar + Specified cigarette Brand (CSB; N = 6), and Candy bar + cigarette Brand of their Choice (CBC; N = 9). A post-session survey evaluated recall of tobacco marketing. Key outcomes were fixations and dwell-time on the cigarette displays at the point-of-sale. Participants spent a median time of 44 seconds during the standardized time evaluated and nearly three-quarters (72%) fixated on the power wall during their purchase, regardless of smoking status (S: 77%, SS: 67%) or purchase task (CO: 44%, CSB: 71%, CBC: 100%). In the post session survey, nearly all participants (96%) indicated they noticed a cigarette brand and 64% were able to describe a specific part of the tobacco wall or recall a promotional offer. Consumers are exposed to point-of-sale tobacco marketing, regardless of smoking status. FDA should consider regulations that limit exposure to point-of-sale tobacco marketing among consumers.
Effects of directional uncertainty on visually-guided joystick pointing.
Berryhill, Marian; Kveraga, Kestutis; Hughes, Howard C
2005-02-01
Reaction times generally follow the predictions of Hick's law as stimulus-response uncertainty increases, although notable exceptions include the oculomotor system. Saccadic and smooth pursuit eye movement reaction times are independent of stimulus-response uncertainty. Previous research showed that joystick pointing to targets, a motor analog of saccadic eye movements, is only modestly affected by increased stimulus-response uncertainty; however, a no-uncertainty condition (simple reaction time to 1 possible target) was not included. Here, we re-evaluate manual joystick pointing including a no-uncertainty condition. Analysis indicated simple joystick pointing reaction times were significantly faster than choice reaction times. Choice reaction times (2, 4, or 8 possible target locations) only slightly increased as the number of possible targets increased. These data suggest that, as with joystick tracking (a motor analog of smooth pursuit eye movements), joystick pointing is more closely approximated by a simple/choice step function than the log function predicted by Hick's law.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Wenyang; Cheung, Yam; Sawant, Amit
2016-05-15
Purpose: To develop a robust and real-time surface reconstruction method on point clouds captured from a 3D surface photogrammetry system. Methods: The authors have developed a robust and fast surface reconstruction method on point clouds acquired by the photogrammetry system, without explicitly solving the partial differential equation required by a typical variational approach. Taking advantage of the overcomplete nature of the acquired point clouds, their method solves and propagates a sparse linear relationship from the point cloud manifold to the surface manifold, assuming both manifolds share similar local geometry. With relatively consistent point cloud acquisitions, the authors propose a sparsemore » regression (SR) model to directly approximate the target point cloud as a sparse linear combination from the training set, assuming that the point correspondences built by the iterative closest point (ICP) is reasonably accurate and have residual errors following a Gaussian distribution. To accommodate changing noise levels and/or presence of inconsistent occlusions during the acquisition, the authors further propose a modified sparse regression (MSR) model to model the potentially large and sparse error built by ICP with a Laplacian prior. The authors evaluated the proposed method on both clinical point clouds acquired under consistent acquisition conditions and on point clouds with inconsistent occlusions. The authors quantitatively evaluated the reconstruction performance with respect to root-mean-squared-error, by comparing its reconstruction results against that from the variational method. Results: On clinical point clouds, both the SR and MSR models have achieved sub-millimeter reconstruction accuracy and reduced the reconstruction time by two orders of magnitude to a subsecond reconstruction time. On point clouds with inconsistent occlusions, the MSR model has demonstrated its advantage in achieving consistent and robust performance despite the introduced occlusions. Conclusions: The authors have developed a fast and robust surface reconstruction method on point clouds captured from a 3D surface photogrammetry system, with demonstrated sub-millimeter reconstruction accuracy and subsecond reconstruction time. It is suitable for real-time motion tracking in radiotherapy, with clear surface structures for better quantifications.« less
Liu, Wenyang; Cheung, Yam; Sawant, Amit; Ruan, Dan
2016-05-01
To develop a robust and real-time surface reconstruction method on point clouds captured from a 3D surface photogrammetry system. The authors have developed a robust and fast surface reconstruction method on point clouds acquired by the photogrammetry system, without explicitly solving the partial differential equation required by a typical variational approach. Taking advantage of the overcomplete nature of the acquired point clouds, their method solves and propagates a sparse linear relationship from the point cloud manifold to the surface manifold, assuming both manifolds share similar local geometry. With relatively consistent point cloud acquisitions, the authors propose a sparse regression (SR) model to directly approximate the target point cloud as a sparse linear combination from the training set, assuming that the point correspondences built by the iterative closest point (ICP) is reasonably accurate and have residual errors following a Gaussian distribution. To accommodate changing noise levels and/or presence of inconsistent occlusions during the acquisition, the authors further propose a modified sparse regression (MSR) model to model the potentially large and sparse error built by ICP with a Laplacian prior. The authors evaluated the proposed method on both clinical point clouds acquired under consistent acquisition conditions and on point clouds with inconsistent occlusions. The authors quantitatively evaluated the reconstruction performance with respect to root-mean-squared-error, by comparing its reconstruction results against that from the variational method. On clinical point clouds, both the SR and MSR models have achieved sub-millimeter reconstruction accuracy and reduced the reconstruction time by two orders of magnitude to a subsecond reconstruction time. On point clouds with inconsistent occlusions, the MSR model has demonstrated its advantage in achieving consistent and robust performance despite the introduced occlusions. The authors have developed a fast and robust surface reconstruction method on point clouds captured from a 3D surface photogrammetry system, with demonstrated sub-millimeter reconstruction accuracy and subsecond reconstruction time. It is suitable for real-time motion tracking in radiotherapy, with clear surface structures for better quantifications.
Liu, Wenyang; Cheung, Yam; Sawant, Amit; Ruan, Dan
2016-01-01
Purpose: To develop a robust and real-time surface reconstruction method on point clouds captured from a 3D surface photogrammetry system. Methods: The authors have developed a robust and fast surface reconstruction method on point clouds acquired by the photogrammetry system, without explicitly solving the partial differential equation required by a typical variational approach. Taking advantage of the overcomplete nature of the acquired point clouds, their method solves and propagates a sparse linear relationship from the point cloud manifold to the surface manifold, assuming both manifolds share similar local geometry. With relatively consistent point cloud acquisitions, the authors propose a sparse regression (SR) model to directly approximate the target point cloud as a sparse linear combination from the training set, assuming that the point correspondences built by the iterative closest point (ICP) is reasonably accurate and have residual errors following a Gaussian distribution. To accommodate changing noise levels and/or presence of inconsistent occlusions during the acquisition, the authors further propose a modified sparse regression (MSR) model to model the potentially large and sparse error built by ICP with a Laplacian prior. The authors evaluated the proposed method on both clinical point clouds acquired under consistent acquisition conditions and on point clouds with inconsistent occlusions. The authors quantitatively evaluated the reconstruction performance with respect to root-mean-squared-error, by comparing its reconstruction results against that from the variational method. Results: On clinical point clouds, both the SR and MSR models have achieved sub-millimeter reconstruction accuracy and reduced the reconstruction time by two orders of magnitude to a subsecond reconstruction time. On point clouds with inconsistent occlusions, the MSR model has demonstrated its advantage in achieving consistent and robust performance despite the introduced occlusions. Conclusions: The authors have developed a fast and robust surface reconstruction method on point clouds captured from a 3D surface photogrammetry system, with demonstrated sub-millimeter reconstruction accuracy and subsecond reconstruction time. It is suitable for real-time motion tracking in radiotherapy, with clear surface structures for better quantifications. PMID:27147347
A Novel Health Evaluation Strategy for Multifunctional Self-Validating Sensors
Shen, Zhengguang; Wang, Qi
2013-01-01
The performance evaluation of sensors is very important in actual application. In this paper, a theory based on multi-variable information fusion is studied to evaluate the health level of multifunctional sensors. A novel conception of health reliability degree (HRD) is defined to indicate a quantitative health level, which is different from traditional so-called qualitative fault diagnosis. To evaluate the health condition from both local and global perspectives, the HRD of a single sensitive component at multiple time points and the overall multifunctional sensor at a single time point are defined, respectively. The HRD methodology is emphasized by using multi-variable data fusion technology coupled with a grey comprehensive evaluation method. In this method, to acquire the distinct importance of each sensitive unit and the sensitivity of different time points, the information entropy and analytic hierarchy process method are used, respectively. In order to verify the feasibility of the proposed strategy, a health evaluating experimental system for multifunctional self-validating sensors was designed. The five different health level situations have been discussed. Successful results show that the proposed method is feasible, the HRD could be used to quantitatively indicate the health level and it does have a fast response to the performance changes of multifunctional sensors. PMID:23291576
Floating-to-Fixed-Point Conversion for Digital Signal Processors
NASA Astrophysics Data System (ADS)
Menard, Daniel; Chillet, Daniel; Sentieys, Olivier
2006-12-01
Digital signal processing applications are specified with floating-point data types but they are usually implemented in embedded systems with fixed-point arithmetic to minimise cost and power consumption. Thus, methodologies which establish automatically the fixed-point specification are required to reduce the application time-to-market. In this paper, a new methodology for the floating-to-fixed point conversion is proposed for software implementations. The aim of our approach is to determine the fixed-point specification which minimises the code execution time for a given accuracy constraint. Compared to previous methodologies, our approach takes into account the DSP architecture to optimise the fixed-point formats and the floating-to-fixed-point conversion process is coupled with the code generation process. The fixed-point data types and the position of the scaling operations are optimised to reduce the code execution time. To evaluate the fixed-point computation accuracy, an analytical approach is used to reduce the optimisation time compared to the existing methods based on simulation. The methodology stages are described and several experiment results are presented to underline the efficiency of this approach.
A test of alternative estimators for volume at time 1 from remeasured point samples
Francis A. Roesch; Edwin J. Green; Charles T. Scott
1993-01-01
Two estimators for volume at time 1 for use with permanent horizontal point samples are evaluated. One estimator, used traditionally, uses only the trees sampled at time 1, while the second estimator, originally presented by Roesch and coauthors (F.A. Roesch, Jr., E.J. Green, and C.T. Scott. 1989. For. Sci. 35(2):281-293). takes advantage of additional sample...
Communication: translational Brownian motion for particles of arbitrary shape.
Cichocki, Bogdan; Ekiel-Jeżewska, Maria L; Wajnryb, Eligiusz
2012-02-21
A single Brownian particle of arbitrary shape is considered. The time-dependent translational mean square displacement W(t) of a reference point at this particle is evaluated from the Smoluchowski equation. It is shown that at times larger than the characteristic time scale of the rotational Brownian relaxation, the slope of W(t) becomes independent of the choice of a reference point. Moreover, it is proved that in the long-time limit, the slope of W(t) is determined uniquely by the trace of the translational-translational mobility matrix μ(tt) evaluated with respect to the hydrodynamic center of mobility. The result is applicable to dynamic light scattering measurements, which indeed are performed in the long-time limit. © 2012 American Institute of Physics
Stock, J D; Calderón Díaz, J A; Rothschild, M F; Mote, B E; Stalder, K J
2018-06-09
Feet and legs of replacement females were objectively evaluated at selection, i.e. approximately 150 days of age (n=319) and post first parity, i.e. any time after weaning of first litter and before 2nd parturition (n=277) to 1) compare feet and leg joint angle ranges between selection and post first parity; 2) identify feet and leg joint angle differences between selection and first three weeks of second gestation; 3) identify feet and leg join angle differences between farms and gestation days during second gestation; and 4) obtain genetic variance components for conformation angles for the two time points measured. Angles for carpal joint (knee), metacarpophalangeal joint (front pastern), metatarsophalangeal joint (rear pastern), tarsal joint (hock), and rear stance were measured using image analysis software. Between selection and post first parity significant differences were observed for all joints measured (P < 0.05). Knee, front and rear pastern angles were less (more flexion), and hock angles were greater (less flexion) as age progressed (P < 0.05), while the rear stance pattern was less (feet further under center) at selection than post first parity (only including measures during first three weeks of second gestation). Only using post first parity leg conformation information, farm was a significant source of variation for front and rear pasterns and rear stance angle measurements (P < 0.05). Knee angle was less (more flexion) (P < 0.05) as gestation age progressed. Heritability estimates were low to moderate (0.04 - 0.35) for all traits measured across time points. Genetic correlations between the same joints at different time points were high (> 0.8) between the front leg joints and low (<0.2) between the rear leg joints. High genetic correlations between time points indicate that the trait can be considered the same at either time point, and low genetic correlations indicate that the trait at different time points should be considered as two separate traits. Minimal change in the front leg suggests conformation traits that remain between selection and post first parity, while larger changes in rear leg indicate that rear leg conformation traits should be evaluated at multiple time periods.
NASA Astrophysics Data System (ADS)
Verfaillie, Deborah; Déqué, Michel; Morin, Samuel; Lafaysse, Matthieu
2017-11-01
We introduce the method ADAMONT v1.0 to adjust and disaggregate daily climate projections from a regional climate model (RCM) using an observational dataset at hourly time resolution. The method uses a refined quantile mapping approach for statistical adjustment and an analogous method for sub-daily disaggregation. The method ultimately produces adjusted hourly time series of temperature, precipitation, wind speed, humidity, and short- and longwave radiation, which can in turn be used to force any energy balance land surface model. While the method is generic and can be employed for any appropriate observation time series, here we focus on the description and evaluation of the method in the French mountainous regions. The observational dataset used here is the SAFRAN meteorological reanalysis, which covers the entire French Alps split into 23 massifs, within which meteorological conditions are provided for several 300 m elevation bands. In order to evaluate the skills of the method itself, it is applied to the ALADIN-Climate v5 RCM using the ERA-Interim reanalysis as boundary conditions, for the time period from 1980 to 2010. Results of the ADAMONT method are compared to the SAFRAN reanalysis itself. Various evaluation criteria are used for temperature and precipitation but also snow depth, which is computed by the SURFEX/ISBA-Crocus model using the meteorological driving data from either the adjusted RCM data or the SAFRAN reanalysis itself. The evaluation addresses in particular the time transferability of the method (using various learning/application time periods), the impact of the RCM grid point selection procedure for each massif/altitude band configuration, and the intervariable consistency of the adjusted meteorological data generated by the method. Results show that the performance of the method is satisfactory, with similar or even better evaluation metrics than alternative methods. However, results for air temperature are generally better than for precipitation. Results in terms of snow depth are satisfactory, which can be viewed as indicating a reasonably good intervariable consistency of the meteorological data produced by the method. In terms of temporal transferability (evaluated over time periods of 15 years only), results depend on the learning period. In terms of RCM grid point selection technique, the use of a complex RCM grid points selection technique, taking into account horizontal but also altitudinal proximity to SAFRAN massif centre points/altitude couples, generally degrades evaluation metrics for high altitudes compared to a simpler grid point selection method based on horizontal distance.
Exploring Listeners' Real-Time Reactions to Regional Accents
ERIC Educational Resources Information Center
Watson, Kevin; Clark, Lynn
2015-01-01
Evaluative reactions to language stimuli are presumably dynamic events, constantly changing through time as the signal unfolds, yet the tools we usually use to capture these reactions provide us with only a snapshot of this process by recording reactions at a single point in time. This paper outlines and evaluates a new methodology which employs…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, W; Sawant, A; Ruan, D
2016-06-15
Purpose: Surface photogrammetry (e.g. VisionRT, C-Rad) provides a noninvasive way to obtain high-frequency measurement for patient motion monitoring in radiotherapy. This work aims to develop a real-time surface reconstruction method on the acquired point clouds, whose acquisitions are subject to noise and missing measurements. In contrast to existing surface reconstruction methods that are usually computationally expensive, the proposed method reconstructs continuous surfaces with comparable accuracy in real-time. Methods: The key idea in our method is to solve and propagate a sparse linear relationship from the point cloud (measurement) manifold to the surface (reconstruction) manifold, taking advantage of the similarity inmore » local geometric topology in both manifolds. With consistent point cloud acquisition, we propose a sparse regression (SR) model to directly approximate the target point cloud as a sparse linear combination from the training set, building the point correspondences by the iterative closest point (ICP) method. To accommodate changing noise levels and/or presence of inconsistent occlusions, we further propose a modified sparse regression (MSR) model to account for the large and sparse error built by ICP, with a Laplacian prior. We evaluated our method on both clinical acquired point clouds under consistent conditions and simulated point clouds with inconsistent occlusions. The reconstruction accuracy was evaluated w.r.t. root-mean-squared-error, by comparing the reconstructed surfaces against those from the variational reconstruction method. Results: On clinical point clouds, both the SR and MSR models achieved sub-millimeter accuracy, with mean reconstruction time reduced from 82.23 seconds to 0.52 seconds and 0.94 seconds, respectively. On simulated point cloud with inconsistent occlusions, the MSR model has demonstrated its advantage in achieving consistent performance despite the introduced occlusions. Conclusion: We have developed a real-time and robust surface reconstruction method on point clouds acquired by photogrammetry systems. It serves an important enabling step for real-time motion tracking in radiotherapy. This work is supported in part by NIH grant R01 CA169102-02.« less
2011-01-01
Background The Prospective Space-Time scan statistic (PST) is widely used for the evaluation of space-time clusters of point event data. Usually a window of cylindrical shape is employed, with a circular or elliptical base in the space domain. Recently, the concept of Minimum Spanning Tree (MST) was applied to specify the set of potential clusters, through the Density-Equalizing Euclidean MST (DEEMST) method, for the detection of arbitrarily shaped clusters. The original map is cartogram transformed, such that the control points are spread uniformly. That method is quite effective, but the cartogram construction is computationally expensive and complicated. Results A fast method for the detection and inference of point data set space-time disease clusters is presented, the Voronoi Based Scan (VBScan). A Voronoi diagram is built for points representing population individuals (cases and controls). The number of Voronoi cells boundaries intercepted by the line segment joining two cases points defines the Voronoi distance between those points. That distance is used to approximate the density of the heterogeneous population and build the Voronoi distance MST linking the cases. The successive removal of edges from the Voronoi distance MST generates sub-trees which are the potential space-time clusters. Finally, those clusters are evaluated through the scan statistic. Monte Carlo replications of the original data are used to evaluate the significance of the clusters. An application for dengue fever in a small Brazilian city is presented. Conclusions The ability to promptly detect space-time clusters of disease outbreaks, when the number of individuals is large, was shown to be feasible, due to the reduced computational load of VBScan. Instead of changing the map, VBScan modifies the metric used to define the distance between cases, without requiring the cartogram construction. Numerical simulations showed that VBScan has higher power of detection, sensitivity and positive predicted value than the Elliptic PST. Furthermore, as VBScan also incorporates topological information from the point neighborhood structure, in addition to the usual geometric information, it is more robust than purely geometric methods such as the elliptic scan. Those advantages were illustrated in a real setting for dengue fever space-time clusters. PMID:21513556
Daniels, Roger L; Kim, Hyun Jung; Min, David B
2006-08-09
Soybean oil with an iodine value of 136 was hydrogenated to have iodine values of 126 and 117. The soybean oils with iodine values of 136, 126, and 117 were randomly interesterified using sodium methoxide. The oxidative stabilities of the hydrogenated and/or interesterified soybean oils were evaluated by measuring the headspace oxygen content by gas chromatography, and the induction time was measured using Rancimat. The melting points of the oils were evaluated by differential scanning calorimetry. Duncan's multiple range test of the headspace oxygen and induction time showed that hydrogenation increased the headspace oxygen content and induction time at alpha = 0.05. Interesterification decreased the headspace oxygen and the induction time for the soybean oils with iodine values of 136, 126, and 117 at alpha = 0.05. Hydrogenation increased the melting points as the iodine value decreased from 136 and 126 to 117 at alpha = 0.05. The random interesterification increased the melting points of soybean oils with iodine values of 136, 126, and 117 at alpha = 0.05. The combined effects of hydrogenation and interesterification increased the oxidative stability of soybean oil at alpha = 0.05 and the melting point at alpha = 0.01. The optimum combination of hydrogenation and random interesterification can improve the oxidative stability and increase the melting point to expand the application of soybean oil in foods.
MSL: A Measure to Evaluate Three-dimensional Patterns in Gene Expression Data
Gutiérrez-Avilés, David; Rubio-Escudero, Cristina
2015-01-01
Microarray technology is highly used in biological research environments due to its ability to monitor the RNA concentration levels. The analysis of the data generated represents a computational challenge due to the characteristics of these data. Clustering techniques are widely applied to create groups of genes that exhibit a similar behavior. Biclustering relaxes the constraints for grouping, allowing genes to be evaluated only under a subset of the conditions. Triclustering appears for the analysis of longitudinal experiments in which the genes are evaluated under certain conditions at several time points. These triclusters provide hidden information in the form of behavior patterns from temporal experiments with microarrays relating subsets of genes, experimental conditions, and time points. We present an evaluation measure for triclusters called Multi Slope Measure, based on the similarity among the angles of the slopes formed by each profile formed by the genes, conditions, and times of the tricluster. PMID:26124630
Independent evaluation of point source fossil fuel CO2 emissions to better than 10%
Turnbull, Jocelyn Christine; Keller, Elizabeth D.; Norris, Margaret W.; Wiltshire, Rachael M.
2016-01-01
Independent estimates of fossil fuel CO2 (CO2ff) emissions are key to ensuring that emission reductions and regulations are effective and provide needed transparency and trust. Point source emissions are a key target because a small number of power plants represent a large portion of total global emissions. Currently, emission rates are known only from self-reported data. Atmospheric observations have the potential to meet the need for independent evaluation, but useful results from this method have been elusive, due to challenges in distinguishing CO2ff emissions from the large and varying CO2 background and in relating atmospheric observations to emission flux rates with high accuracy. Here we use time-integrated observations of the radiocarbon content of CO2 (14CO2) to quantify the recently added CO2ff mole fraction at surface sites surrounding a point source. We demonstrate that both fast-growing plant material (grass) and CO2 collected by absorption into sodium hydroxide solution provide excellent time-integrated records of atmospheric 14CO2. These time-integrated samples allow us to evaluate emissions over a period of days to weeks with only a modest number of measurements. Applying the same time integration in an atmospheric transport model eliminates the need to resolve highly variable short-term turbulence. Together these techniques allow us to independently evaluate point source CO2ff emission rates from atmospheric observations with uncertainties of better than 10%. This uncertainty represents an improvement by a factor of 2 over current bottom-up inventory estimates and previous atmospheric observation estimates and allows reliable independent evaluation of emissions. PMID:27573818
Independent evaluation of point source fossil fuel CO2 emissions to better than 10%.
Turnbull, Jocelyn Christine; Keller, Elizabeth D; Norris, Margaret W; Wiltshire, Rachael M
2016-09-13
Independent estimates of fossil fuel CO2 (CO2ff) emissions are key to ensuring that emission reductions and regulations are effective and provide needed transparency and trust. Point source emissions are a key target because a small number of power plants represent a large portion of total global emissions. Currently, emission rates are known only from self-reported data. Atmospheric observations have the potential to meet the need for independent evaluation, but useful results from this method have been elusive, due to challenges in distinguishing CO2ff emissions from the large and varying CO2 background and in relating atmospheric observations to emission flux rates with high accuracy. Here we use time-integrated observations of the radiocarbon content of CO2 ((14)CO2) to quantify the recently added CO2ff mole fraction at surface sites surrounding a point source. We demonstrate that both fast-growing plant material (grass) and CO2 collected by absorption into sodium hydroxide solution provide excellent time-integrated records of atmospheric (14)CO2 These time-integrated samples allow us to evaluate emissions over a period of days to weeks with only a modest number of measurements. Applying the same time integration in an atmospheric transport model eliminates the need to resolve highly variable short-term turbulence. Together these techniques allow us to independently evaluate point source CO2ff emission rates from atmospheric observations with uncertainties of better than 10%. This uncertainty represents an improvement by a factor of 2 over current bottom-up inventory estimates and previous atmospheric observation estimates and allows reliable independent evaluation of emissions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krityakierne, Tipaluck; Akhtar, Taimoor; Shoemaker, Christine A.
This paper presents a parallel surrogate-based global optimization method for computationally expensive objective functions that is more effective for larger numbers of processors. To reach this goal, we integrated concepts from multi-objective optimization and tabu search into, single objective, surrogate optimization. Our proposed derivative-free algorithm, called SOP, uses non-dominated sorting of points for which the expensive function has been previously evaluated. The two objectives are the expensive function value of the point and the minimum distance of the point to previously evaluated points. Based on the results of non-dominated sorting, P points from the sorted fronts are selected as centersmore » from which many candidate points are generated by random perturbations. Based on surrogate approximation, the best candidate point is subsequently selected for expensive evaluation for each of the P centers, with simultaneous computation on P processors. Centers that previously did not generate good solutions are tabu with a given tenure. We show almost sure convergence of this algorithm under some conditions. The performance of SOP is compared with two RBF based methods. The test results show that SOP is an efficient method that can reduce time required to find a good near optimal solution. In a number of cases the efficiency of SOP is so good that SOP with 8 processors found an accurate answer in less wall-clock time than the other algorithms did with 32 processors.« less
NASA Astrophysics Data System (ADS)
Zetterlind, Virgil E., III; Magee, Eric P.
2002-06-01
This study extends branch point tolerant phase reconstructor research to examine the effect of finite time delays and measurement error on system performance. Branch point tolerant phase reconstruction is particularly applicable to atmospheric laser weapon and communication systems, which operate in extended turbulence. We examine the relative performance of a least squares reconstructor, least squares plus hidden phase reconstructor, and a Goldstein branch point reconstructor for various correction time-delays and measurement noise scenarios. Performance is evaluated using a wave-optics simulation that models a 100km atmospheric propagation of a point source beacon to a transmit/receive aperture. Phase-only corrections are then calculated using the various reconstructor algorithms and applied to an outgoing uniform field. Point Strehl is used as the performance metric. Results indicate that while time delays and measurement noise reduce the performance of branch point tolerant reconstructors, these reconstructors can still outperform least squares implementations in many cases. We also show that branch point detection becomes the limiting factor in measurement noise corrupted scenarios.
NASA Astrophysics Data System (ADS)
Tiwari, Pallavi; Danish, Shabbar; Wong, Stephen; Madabhushi, Anant
2013-03-01
Laser-induced interstitial thermal therapy (LITT) has recently emerged as a new, less invasive alternative to craniotomy for treating epilepsy; which allows for focussed delivery of laser energy monitored in real time by MRI, for precise removal of the epileptogenic foci. Despite being minimally invasive, the effects of laser ablation on the epileptogenic foci (reflected by changes in MR imaging markers post-LITT) are currently unknown. In this work, we present a quantitative framework for evaluating LITT-related changes by quantifying per-voxel changes in MR imaging markers which may be more reflective of local treatment related changes (TRC) that occur post-LITT, as compared to the standard volumetric analysis which involves monitoring a more global volume change across pre-, and post-LITT MRI. Our framework focuses on three objectives: (a) development of temporal MRI signatures that characterize TRC corresponding to patients with seizure freedom by comparing differences in MR imaging markers and monitoring them over time, (b) identification of the optimal time point when early LITT induced effects (such as edema and mass effect) subside by monitoring TRC at subsequent time-points post-LITT, and (c) identification of contributions of individual MRI protocols towards characterizing LITT-TRC for epilepsy by identifying MR markers that change most dramatically over time and employ individual contributions to create a more optimal weighted MP-MRI temporal profile that can better characterize TRC compared to any individual imaging marker. A cohort of patients were monitored at different time points post-LITT via MP-MRI involving T1-w, T2-w, T2-GRE, T2-FLAIR, and apparent diffusion coefficient (ADC) protocols. Post affine registration of individual MRI protocols to a reference MRI protocol pre-LITT, differences in individual MR markers are computed on a per-voxel basis, at different time-points with respect to baseline (pre-LITT) MRI as well as across subsequent time-points. A time-dependent MRI profile corresponding to successful (seizure-free) is then created that captures changes in individual MR imaging markers over time. Our preliminary analysis on two patient studies suggests that (a) LITT related changes (attributed to swelling and edema) appear to subside within 4-weeks post-LITT, (b) ADC may be more sensitive for evaluating early TRC (up to 3-months), and T1-w may be more sensitive in evaluating early delayed TRC (1-month, 3-months), while T2-w and T2-FLAIR appeared to be more sensitive in identifying late TRC (around 6-months post-LITT) compared to the other MRI protocols under evaluation. T2-GRE was found to be only nominally sensitive in identifying TRC at any follow-up time-point post-LITT. The framework presented in this work thus serves as an important precursor to a comprehensive treatment evaluation framework that can be used to identify sensitive MR markers corresponding to patient response (seizure-freedom or seizure recurrence), with an ultimate objective of making prognostic predictions about patient outcome post-LITT.
Green, Lawrence J.
2018-01-01
Objective: The aim of this study was to evaluate the safety and efficacy of an herbal and zinc pyrithione shampoo and a scalp lotion (Kamedis Derma-Scalp Dandruff Therapy, Kamedis Ltd., Tel Aviv, Israel) for the treatment of scalp seborrheic dermatitis and dandruff. Design: This was an interventional, open-label, safety and efficacy study. Setting: This open-label study was conducted at Consumer Product Testing Company Inc. in Fairfield, New Jersey. At the baseline visit (Day 0), an examination of the scalp was conducted by a board-certified dermatologist. The entire scalp was evaluated for evidence of seborrheic dermatitis using the Adherent Scalp Flaking Score with a 10-point scale. Only subjects with evidence of moderate-to-greater seborrheic dermatitis or moderate-to-greater dandruff were deemed qualified for inclusion in the study. Participants: Fifty subjects were recruited and included in the study. Measurements: Study subjects were evaluated by the same dermatologist for erythema and flaking at Days 0, 14, 28, and 42 using a five-point scale for each parameter. At each time point, a total severity score was calculated based on the findings of the evaluations. Following the scalp evaluation, each subject had a standardized digital photograph taken of his or her scalp. Each subject was also asked to answer a satisfaction questionnaire regarding the product treatment enhancement and characteristics. Results: A reduction in both parameters evaluated was seen at all time points. Statistical significance was achieved at each time point when compared with the baseline visit. In addition, the subjects expressed a high degree of satisfaction with the treatment. No adverse events were reported during this study. Conclusion: The study showed that the herbal zinc pyrithione shampoo and scalp lotion provided improvement in the main symptoms of seborrheic dermatitis. PMID:29410727
A Parallel Particle Swarm Optimization Algorithm Accelerated by Asynchronous Evaluations
NASA Technical Reports Server (NTRS)
Venter, Gerhard; Sobieszczanski-Sobieski, Jaroslaw
2005-01-01
A parallel Particle Swarm Optimization (PSO) algorithm is presented. Particle swarm optimization is a fairly recent addition to the family of non-gradient based, probabilistic search algorithms that is based on a simplified social model and is closely tied to swarming theory. Although PSO algorithms present several attractive properties to the designer, they are plagued by high computational cost as measured by elapsed time. One approach to reduce the elapsed time is to make use of coarse-grained parallelization to evaluate the design points. Previous parallel PSO algorithms were mostly implemented in a synchronous manner, where all design points within a design iteration are evaluated before the next iteration is started. This approach leads to poor parallel speedup in cases where a heterogeneous parallel environment is used and/or where the analysis time depends on the design point being analyzed. This paper introduces an asynchronous parallel PSO algorithm that greatly improves the parallel e ciency. The asynchronous algorithm is benchmarked on a cluster assembled of Apple Macintosh G5 desktop computers, using the multi-disciplinary optimization of a typical transport aircraft wing as an example.
Sastre I Riba, Sylvia; Fonseca-Pedrero, Eduardo; Santarén-Rosell, Marta; Urraca-Martínez, María Luz
2015-01-01
The objective of this study was to evaluate the satisfaction of an extracurricular enrichment program of the cognitive and personal management of participants with high intellectual ability. At the first time point, the sample consisted of n= 38 participants, and n= 20 parents; n= 48 participants at the second time point; and n= 60 participants at the third time point. The Satisfaction Questionnaire (CSA in Spanish), both for students (CSA-S) and for parents (CSA-P), was constructed. The CSA-S scores showed adequate psychometric properties. Exploratory factor analysis yielded a unidimensional structure. Cronbach’s alpha ranged between 85 and .86. Test-retest reliability was 0.45 (p<.05). The generalizability coefficient was .98. A high percentage of the sample was satisfied with the program, perceived improvements in cognitive and emotional management, motivation and interest in learning, and in the frequency and quality of their interpersonal relationships. The evaluation of educational programs is necessary in order to determine the efficacy and the effects of their implementation on the participants’ personal and intellectual management.
Serial MRI evaluation following arthroscopic rotator cuff repair in double-row technique.
Stahnke, Katharina; Nikulka, Constanze; Diederichs, Gerd; Haneveld, Hendrik; Scheibel, Markus; Gerhardt, Christian
2016-05-01
So far, recurrent rotator cuff defects are described to occur in the early postoperative period after arthroscopic repair. The aim of this study was to evaluate the musculotendinous structure of the supraspinatus, as well as bone marrow edema or osteolysis after arthroscopic double-row repair. Therefore, magnetic resonance (MR) images were performed at defined intervals up to 2 years postoperatively. Case series; Level of evidence, 3. MR imaging was performed within 7 days, 3, 6, 12, 26, 52 and 108 weeks after surgery. All patients were operated using an arthroscopic modified suture bridge technique. Tendon integrity, tendon retraction ["foot-print-coverage" (FPC)], muscular atrophy and fatty infiltration (signal intensity analysis) were measured at all time points. Furthermore, postoperative bone marrow edema and signs of osteolysis were assessed. MR images of 13 non-consecutive patients (6f/7m, ∅ age 61.05 ± 7.7 years) could be evaluated at all time points until ∅ 108 weeks postoperatively. 5/6 patients with recurrent defect at final follow-up displayed a time of failure between 12 and 24 months after surgery. Predominant mode of failure was medial cuff failures in 4/6 cases. The initial FPC increased significantly up to 2 years follow-up (p = 0.004). Evaluations of muscular atrophy or fatty infiltration were not significant different comparing the results of all time points (p > 0.05). Postoperative bone marrow edema disappeared completely at 6 months after surgery, whereas signs of osteolysis appeared at 3 months follow-up and increased to final follow-up. Recurrent defects after arthroscopic reconstruction of supraspinatus tears in modified suture bridge technique seem to occur between 12 and 24 months after surgery. Serial MRI evaluation shows good muscle structure at all time points. Postoperative bone marrow edema disappears completely several months after surgery. Signs of osteolysis seem to appear caused by bio-absorbable anchor implantations.
The real time multi point Thomson scattering diagnostic at NSTX-U
NASA Astrophysics Data System (ADS)
Laggner, Florian; Kolemen, Egemen; Diallo, Ahmed; Leblanc, Benoit; Rozenblat, Roman; Tchilinguirian, Greg; NSTX-U Team Team
2017-10-01
This contribution presents the upgrade of the multi point Thomson scattering (MPTS) diagnostic for real time application. As a key diagnostic at NSTX-U, the MPTS diagnostic simultaneously measures the electron density (ne) and electron temperature (Te) profiles of a plasma discharge. Therefore, this powerful diagnostic can directly access the electron pressure of the plasma. Currently, only post-discharge evaluation of the data is available, however, since the plasma pressure is one important drive for instabilities, real time measurements of this quantities would be beneficial for plasma control. In a first step, ten MPTS channels were equipped with real time electronics, which improve the data acquisition rate by five orders of magnitude. The commissioning of the system is ongoing and first benchmarks of the real time evaluation routines against the standard, post-discharge evaluation show promising results: The Te as well as ne profiles of both types of analyses agree within their uncertainties. This work was supported by the US Department of Energy under DE-SC0015878 and DE-SC0015480.
Zhang, Xudong
2002-10-01
This work describes a new approach that allows an angle-domain human movement model to generate, via forward kinematics, Cartesian-space human movement representation with otherwise inevitable end-point offset nullified but much of the kinematic authenticity retained. The approach incorporates a rectification procedure that determines the minimum postural angle change at the final frame to correct the end-point offset, and a deformation procedure that deforms the angle profile accordingly to preserve maximum original kinematic authenticity. Two alternative deformation schemes, named amplitude-proportional (AP) and time-proportional (TP) schemes, are proposed and formulated. As an illustration and empirical evaluation, the proposed approach, along with two deformation schemes, was applied to a set of target-directed right-hand reaching movements that had been previously measured and modeled. The evaluation showed that both deformation schemes nullified the final frame end-point offset and significantly reduced time-averaged position errors for the end-point as well as the most distal intermediate joint while causing essentially no change in the remaining joints. A comparison between the two schemes based on time-averaged joint and end-point position errors indicated that overall the TP scheme outperformed the AP scheme. In addition, no statistically significant difference in time-averaged angle error was identified between the raw prediction and either of the deformation schemes, nor between the two schemes themselves, suggesting minimal angle-domain distortion incurred by the deformation.
Confidence intervals for the first crossing point of two hazard functions.
Cheng, Ming-Yen; Qiu, Peihua; Tan, Xianming; Tu, Dongsheng
2009-12-01
The phenomenon of crossing hazard rates is common in clinical trials with time to event endpoints. Many methods have been proposed for testing equality of hazard functions against a crossing hazards alternative. However, there has been relatively few approaches available in the literature for point or interval estimation of the crossing time point. The problem of constructing confidence intervals for the first crossing time point of two hazard functions is considered in this paper. After reviewing a recent procedure based on Cox proportional hazard modeling with Box-Cox transformation of the time to event, a nonparametric procedure using the kernel smoothing estimate of the hazard ratio is proposed. The proposed procedure and the one based on Cox proportional hazard modeling with Box-Cox transformation of the time to event are both evaluated by Monte-Carlo simulations and applied to two clinical trial datasets.
Krityakierne, Tipaluck; Akhtar, Taimoor; Shoemaker, Christine A.
2016-02-02
This paper presents a parallel surrogate-based global optimization method for computationally expensive objective functions that is more effective for larger numbers of processors. To reach this goal, we integrated concepts from multi-objective optimization and tabu search into, single objective, surrogate optimization. Our proposed derivative-free algorithm, called SOP, uses non-dominated sorting of points for which the expensive function has been previously evaluated. The two objectives are the expensive function value of the point and the minimum distance of the point to previously evaluated points. Based on the results of non-dominated sorting, P points from the sorted fronts are selected as centersmore » from which many candidate points are generated by random perturbations. Based on surrogate approximation, the best candidate point is subsequently selected for expensive evaluation for each of the P centers, with simultaneous computation on P processors. Centers that previously did not generate good solutions are tabu with a given tenure. We show almost sure convergence of this algorithm under some conditions. The performance of SOP is compared with two RBF based methods. The test results show that SOP is an efficient method that can reduce time required to find a good near optimal solution. In a number of cases the efficiency of SOP is so good that SOP with 8 processors found an accurate answer in less wall-clock time than the other algorithms did with 32 processors.« less
Venter, Anre; Maxwell, Scott E; Bolig, Erika
2002-06-01
Adding a pretest as a covariate to a randomized posttest-only design increases statistical power, as does the addition of intermediate time points to a randomized pretest-posttest design. Although typically 5 waves of data are required in this instance to produce meaningful gains in power, a 3-wave intensive design allows the evaluation of the straight-line growth model and may reduce the effect of missing data. The authors identify the statistically most powerful method of data analysis in the 3-wave intensive design. If straight-line growth is assumed, the pretest-posttest slope must assume fairly extreme values for the intermediate time point to increase power beyond the standard analysis of covariance on the posttest with the pretest as covariate, ignoring the intermediate time point.
Gaál, T; Halmay, Dóra; Kocsis, R; Abonyi-Tóth, Z
2007-09-01
The effect of two nonsteroidal anti-inflammatory drugs (carprofen and ketoprofen) on platelet adhesion and aggregation functions was evaluated by the PFA-100 analyser (Dade-Behring, CA, U.S.A.) using its collagen-adenosine diphosphate (ADP) and collagen-epinephrine (EPI) cartridges. The function of platelets was evaluated in 55 healthy dogs, in 7 dogs treated with ketoprofen and in 31 dogs treated with carprofen in a therapeutic dose for minimum 5 days. The therapeutic doses of carprofen had no effect on the closure time of PFA-100 (which is the marker of platelet function) but ketoprofen caused a significant increase when using collagen-EPI stimulation The closure times for both the healthy (control) and the treated dogs using EPI cartridges were often longer than the upper default cut-off point (300 sec) of the device. The PFA-100 analyser with collagen-ADP cartridges could be a useful tool for veterinary applications including the evaluation of platelet aggregation in dogs treated with NSAIDs. The upper cut-off point of PFA-100 might be extended.
Gill, Sharlene; Sargent, Daniel
2006-06-01
The intent of adjuvant therapy is to eradicate micro-metastatic residual disease following curative resection with the goal of preventing or delaying recurrence. The time-honored standard for demonstrating efficacy of new adjuvant therapies is an improvement in overall survival (OS). This typically requires phase III trials of large sample size with lengthy follow-up. With the intent of reducing the cost and time of completing such trials, there is considerable interest in developing alternative or surrogate end points. A surrogate end point may be employed as a substitute to directly assess the effects of an intervention on an already accepted clinical end point such as mortality. When used judiciously, surrogate end points can accelerate the evaluation of new therapies, resulting in the more timely dissemination of effective therapies to patients. The current review provides a perspective on the suitability and validity of disease-free survival (DFS) as an alternative end point for OS. Criteria for establishing surrogacy and the advantages and limitations associated with the use of DFS as a primary end point in adjuvant clinical trials and as the basis for approval of new adjuvant therapies are discussed.
Time Series UAV Image-Based Point Clouds for Landslide Progression Evaluation Applications
Moussa, Adel; El-Sheimy, Naser; Habib, Ayman
2017-01-01
Landslides are major and constantly changing threats to urban landscapes and infrastructure. It is essential to detect and capture landslide changes regularly. Traditional methods for monitoring landslides are time-consuming, costly, dangerous, and the quality and quantity of the data is sometimes unable to meet the necessary requirements of geotechnical projects. This motivates the development of more automatic and efficient remote sensing approaches for landslide progression evaluation. Automatic change detection involving low-altitude unmanned aerial vehicle image-based point clouds, although proven, is relatively unexplored, and little research has been done in terms of accounting for volumetric changes. In this study, a methodology for automatically deriving change displacement rates, in a horizontal direction based on comparisons between extracted landslide scarps from multiple time periods, has been developed. Compared with the iterative closest projected point (ICPP) registration method, the developed method takes full advantage of automated geometric measuring, leading to fast processing. The proposed approach easily processes a large number of images from different epochs and enables the creation of registered image-based point clouds without the use of extensive ground control point information or further processing such as interpretation and image correlation. The produced results are promising for use in the field of landslide research. PMID:29057847
Time Series UAV Image-Based Point Clouds for Landslide Progression Evaluation Applications.
Al-Rawabdeh, Abdulla; Moussa, Adel; Foroutan, Marzieh; El-Sheimy, Naser; Habib, Ayman
2017-10-18
Landslides are major and constantly changing threats to urban landscapes and infrastructure. It is essential to detect and capture landslide changes regularly. Traditional methods for monitoring landslides are time-consuming, costly, dangerous, and the quality and quantity of the data is sometimes unable to meet the necessary requirements of geotechnical projects. This motivates the development of more automatic and efficient remote sensing approaches for landslide progression evaluation. Automatic change detection involving low-altitude unmanned aerial vehicle image-based point clouds, although proven, is relatively unexplored, and little research has been done in terms of accounting for volumetric changes. In this study, a methodology for automatically deriving change displacement rates, in a horizontal direction based on comparisons between extracted landslide scarps from multiple time periods, has been developed. Compared with the iterative closest projected point (ICPP) registration method, the developed method takes full advantage of automated geometric measuring, leading to fast processing. The proposed approach easily processes a large number of images from different epochs and enables the creation of registered image-based point clouds without the use of extensive ground control point information or further processing such as interpretation and image correlation. The produced results are promising for use in the field of landslide research.
Data Processing and Quality Evaluation of a Boat-Based Mobile Laser Scanning System
Vaaja, Matti; Kukko, Antero; Kaartinen, Harri; Kurkela, Matti; Kasvi, Elina; Flener, Claude; Hyyppä, Hannu; Hyyppä, Juha; Järvelä, Juha; Alho, Petteri
2013-01-01
Mobile mapping systems (MMSs) are used for mapping topographic and urban features which are difficult and time consuming to measure with other instruments. The benefits of MMSs include efficient data collection and versatile usability. This paper investigates the data processing steps and quality of a boat-based mobile mapping system (BoMMS) data for generating terrain and vegetation points in a river environment. Our aim in data processing was to filter noise points, detect shorelines as well as points below water surface and conduct ground point classification. Previous studies of BoMMS have investigated elevation accuracies and usability in detection of fluvial erosion and deposition areas. The new findings concerning BoMMS data are that the improved data processing approach allows for identification of multipath reflections and shoreline delineation. We demonstrate the possibility to measure bathymetry data in shallow (0–1 m) and clear water. Furthermore, we evaluate for the first time the accuracy of the BoMMS ground points classification compared to manually classified data. We also demonstrate the spatial variations of the ground point density and assess elevation and vertical accuracies of the BoMMS data. PMID:24048340
Data processing and quality evaluation of a boat-based mobile laser scanning system.
Vaaja, Matti; Kukko, Antero; Kaartinen, Harri; Kurkela, Matti; Kasvi, Elina; Flener, Claude; Hyyppä, Hannu; Hyyppä, Juha; Järvelä, Juha; Alho, Petteri
2013-09-17
Mobile mapping systems (MMSs) are used for mapping topographic and urban features which are difficult and time consuming to measure with other instruments. The benefits of MMSs include efficient data collection and versatile usability. This paper investigates the data processing steps and quality of a boat-based mobile mapping system (BoMMS) data for generating terrain and vegetation points in a river environment. Our aim in data processing was to filter noise points, detect shorelines as well as points below water surface and conduct ground point classification. Previous studies of BoMMS have investigated elevation accuracies and usability in detection of fluvial erosion and deposition areas. The new findings concerning BoMMS data are that the improved data processing approach allows for identification of multipath reflections and shoreline delineation. We demonstrate the possibility to measure bathymetry data in shallow (0-1 m) and clear water. Furthermore, we evaluate for the first time the accuracy of the BoMMS ground points classification compared to manually classified data. We also demonstrate the spatial variations of the ground point density and assess elevation and vertical accuracies of the BoMMS data.
Curve Set Feature-Based Robust and Fast Pose Estimation Algorithm
Hashimoto, Koichi
2017-01-01
Bin picking refers to picking the randomly-piled objects from a bin for industrial production purposes, and robotic bin picking is always used in automated assembly lines. In order to achieve a higher productivity, a fast and robust pose estimation algorithm is necessary to recognize and localize the randomly-piled parts. This paper proposes a pose estimation algorithm for bin picking tasks using point cloud data. A novel descriptor Curve Set Feature (CSF) is proposed to describe a point by the surface fluctuation around this point and is also capable of evaluating poses. The Rotation Match Feature (RMF) is proposed to match CSF efficiently. The matching process combines the idea of the matching in 2D space of origin Point Pair Feature (PPF) algorithm with nearest neighbor search. A voxel-based pose verification method is introduced to evaluate the poses and proved to be more than 30-times faster than the kd-tree-based verification method. Our algorithm is evaluated against a large number of synthetic and real scenes and proven to be robust to noise, able to detect metal parts, more accurately and more than 10-times faster than PPF and Oriented, Unique and Repeatable (OUR)-Clustered Viewpoint Feature Histogram (CVFH). PMID:28771216
Brazzale, Alessandra R; Küchenhoff, Helmut; Krügel, Stefanie; Schiergens, Tobias S; Trentzsch, Heiko; Hartl, Wolfgang
2018-04-05
We present a new method for estimating a change point in the hazard function of a survival distribution assuming a constant hazard rate after the change point and a decreasing hazard rate before the change point. Our method is based on fitting a stump regression to p values for testing hazard rates in small time intervals. We present three real data examples describing survival patterns of severely ill patients, whose excess mortality rates are known to persist far beyond hospital discharge. For designing survival studies in these patients and for the definition of hospital performance metrics (e.g. mortality), it is essential to define adequate and objective end points. The reliable estimation of a change point will help researchers to identify such end points. By precisely knowing this change point, clinicians can distinguish between the acute phase with high hazard (time elapsed after admission and before the change point was reached), and the chronic phase (time elapsed after the change point) in which hazard is fairly constant. We show in an extensive simulation study that maximum likelihood estimation is not robust in this setting, and we evaluate our new estimation strategy including bootstrap confidence intervals and finite sample bias correction.
A quantitative evaluation of two methods for preserving hair samples
Roon, David A.; Waits, L.P.; Kendall, K.C.
2003-01-01
Hair samples are an increasingly important DNA source for wildlife studies, yet optimal storage methods and DNA degradation rates have not been rigorously evaluated. We tested amplification success rates over a one-year storage period for DNA extracted from brown bear (Ursus arctos) hair samples preserved using silica desiccation and -20C freezing. For three nuclear DNA microsatellites, success rates decreased significantly after a six-month time point, regardless of storage method. For a 1000 bp mitochondrial fragment, a similar decrease occurred after a two-week time point. Minimizing delays between collection and DNA extraction will maximize success rates for hair-based noninvasive genetic sampling projects.
Fast Semantic Segmentation of 3d Point Clouds with Strongly Varying Density
NASA Astrophysics Data System (ADS)
Hackel, Timo; Wegner, Jan D.; Schindler, Konrad
2016-06-01
We describe an effective and efficient method for point-wise semantic classification of 3D point clouds. The method can handle unstructured and inhomogeneous point clouds such as those derived from static terrestrial LiDAR or photogammetric reconstruction; and it is computationally efficient, making it possible to process point clouds with many millions of points in a matter of minutes. The key issue, both to cope with strong variations in point density and to bring down computation time, turns out to be careful handling of neighborhood relations. By choosing appropriate definitions of a point's (multi-scale) neighborhood, we obtain a feature set that is both expressive and fast to compute. We evaluate our classification method both on benchmark data from a mobile mapping platform and on a variety of large, terrestrial laser scans with greatly varying point density. The proposed feature set outperforms the state of the art with respect to per-point classification accuracy, while at the same time being much faster to compute.
Lacerda, Vánia A; Pereira, Leandro O; Hirata JUNIOR, Raphael; Perez, Cesar R
2015-12-01
To evaluate the effectiveness of disinfection/sterilization methods and their effects on polishing capacity, micomorphology, and composition of two different composite fiishing and polishing instruments. Two brands of finishing and polishing instruments (Jiffy and Optimize), were analyzed. For the antimicrobial test, 60 points (30 of each brand) were used for polishing composite restorations and submitted to three different groups of disinfection/sterilization methods: none (control), autoclaving, and immersion in peracetic acid for 60 minutes. The in vitro tests were performed to evaluate the polishing performance on resin composite disks (Amelogen) using a 3D scanner (Talyscan) and to evaluate the effects on the points' surface composition (XRF) and micromorphology (MEV) after completing a polishing and sterilizing routine five times. Both sterilization/disinfection methods were efficient against oral cultivable organisms and no deleterious modification was observed to point surface.
A General Method for Solving Systems of Non-Linear Equations
NASA Technical Reports Server (NTRS)
Nachtsheim, Philip R.; Deiss, Ron (Technical Monitor)
1995-01-01
The method of steepest descent is modified so that accelerated convergence is achieved near a root. It is assumed that the function of interest can be approximated near a root by a quadratic form. An eigenvector of the quadratic form is found by evaluating the function and its gradient at an arbitrary point and another suitably selected point. The terminal point of the eigenvector is chosen to lie on the line segment joining the two points. The terminal point found lies on an axis of the quadratic form. The selection of a suitable step size at this point leads directly to the root in the direction of steepest descent in a single step. Newton's root finding method not infrequently diverges if the starting point is far from the root. However, the current method in these regions merely reverts to the method of steepest descent with an adaptive step size. The current method's performance should match that of the Levenberg-Marquardt root finding method since they both share the ability to converge from a starting point far from the root and both exhibit quadratic convergence near a root. The Levenberg-Marquardt method requires storage for coefficients of linear equations. The current method which does not require the solution of linear equations requires more time for additional function and gradient evaluations. The classic trade off of time for space separates the two methods.
Bronner, S; Pompei, D; Elkhaïli, H; Dhoyen, N; Monteil, H; Jehl, F
2001-10-01
The aim of the study was to evaluate the in vitro/ex vivo bactericidal activity of a new coamoxiclav single-dose sachet formulation (1 g amoxicillin + 0.125 g clavulanic acid) against a beta-lactamase-producing strain of Haemophilus influenzae. The evaluation covered the 12 h period after antibiotic administration. Serum specimens from the 12 healthy volunteers included in the pharmacokinetic study were pooled by time point and in equal volumes. Eight of 12 pharmacokinetic sampling time points were included in the study. At time points 0.5, 0.75, 1, 1.5, 2.5, 5, 8 and 12 h post-dosing, the kinetics of bactericidal activity were determined for each of the serial dilutions. Each specimen was serially diluted from 1:2 to 1:256. The index of surviving bacteria (ISB) was subsequently determined for each pharmacokinetic time point. For all the serum samples, bactericidal activity was fast (3-6 h), marked (3-6 log(10) reduction in the initial inoculum) and sustained over the 12 h between-dosing interval. The results obtained also confirmed that the potency of the amoxicillin plus clavulanic acid combination was time dependent against the species under study and that the time interval over which the concentrations were greater than the MIC (t > MIC) was 100% for the strain under study. The data thus generated constitute an interesting prerequisite with a view to using co-amoxiclav 1.125 g in a bd oral regimen.
Applied Time Domain Stability Margin Assessment for Nonlinear Time-Varying Systems
NASA Technical Reports Server (NTRS)
Kiefer, J. M.; Johnson, M. D.; Wall, J. H.; Dominguez, A.
2016-01-01
The baseline stability margins for NASA's Space Launch System (SLS) launch vehicle were generated via the classical approach of linearizing the system equations of motion and determining the gain and phase margins from the resulting frequency domain model. To improve the fidelity of the classical methods, the linear frequency domain approach can be extended by replacing static, memoryless nonlinearities with describing functions. This technique, however, does not address the time varying nature of the dynamics of a launch vehicle in flight. An alternative technique for the evaluation of the stability of the nonlinear launch vehicle dynamics along its trajectory is to incrementally adjust the gain and/or time delay in the time domain simulation until the system exhibits unstable behavior. This technique has the added benefit of providing a direct comparison between the time domain and frequency domain tools in support of simulation validation. This technique was implemented by using the Stability Aerospace Vehicle Analysis Tool (SAVANT) computer simulation to evaluate the stability of the SLS system with the Adaptive Augmenting Control (AAC) active and inactive along its ascent trajectory. The gains for which the vehicle maintains apparent time-domain stability defines the gain margins, and the time delay similarly defines the phase margin. This method of extracting the control stability margins from the time-domain simulation is relatively straightforward and the resultant margins can be compared to the linearized system results. The sections herein describe the techniques employed to extract the time-domain margins, compare the results between these nonlinear and the linear methods, and provide explanations for observed discrepancies. The SLS ascent trajectory was simulated with SAVANT and the classical linear stability margins were evaluated at one second intervals. The linear analysis was performed with the AAC algorithm disabled to attain baseline stability margins. At each time point, the system was linearized about the current operating point using Simulink's built-in solver. Each linearized system in time was evaluated for its rigid-body gain margin (high frequency gain margin), rigid-body phase margin, and aero gain margin (low frequency gain margin) for each control axis. Using the stability margins derived from the baseline linearization approach, the time domain derived stability margins were determined by executing time domain simulations in which axis-specific incremental gain and phase adjustments were made to the nominal system about the expected neutral stability point at specific flight times. The baseline stability margin time histories were used to shift the system gain to various values around the zero margin point such that a precise amount of expected gain margin was maintained throughout flight. When assessing the gain margins, the gain was applied starting at the time point under consideration, thereafter following the variation in the margin found in the linear analysis. When assessing the rigid-body phase margin, a constant time delay was applied to the system starting at the time point under consideration. If the baseline stability margins were correctly determined via the linear analysis, the time domain simulation results should contain unstable behavior at certain gain and phase values. Examples will be shown from repeated simulations with variable added gain and phase lag. Faithfulness of margins calculated from the linear analysis to the nonlinear system will be demonstrated.
Shortest path problem on a grid network with unordered intermediate points
NASA Astrophysics Data System (ADS)
Saw, Veekeong; Rahman, Amirah; Eng Ong, Wen
2017-10-01
We consider a shortest path problem with single cost factor on a grid network with unordered intermediate points. A two stage heuristic algorithm is proposed to find a feasible solution path within a reasonable amount of time. To evaluate the performance of the proposed algorithm, computational experiments are performed on grid maps of varying size and number of intermediate points. Preliminary results for the problem are reported. Numerical comparisons against brute forcing show that the proposed algorithm consistently yields solutions that are within 10% of the optimal solution and uses significantly less computation time.
González Isasi, A; Echeburúa, E; Limiñana, J M; González-Pinto, A
2014-03-01
The aim of this research, which represents an additional and longer follow-up to a previous trial, was to evaluate a 5-year follow-up study of a combined treatment (pharmacological+psychoeducational and cognitive-behavioral therapy) as compared with a standard pharmacological treatment in patients with refractory bipolar disorder. Forty patients were randomly assigned to either an Experimental group-under combined treatment - or a Control group - under pharmacological treatment. Data were analyzed by analysis of variance (ANOVA), with repeated measures at different evaluation time points. Between-group differences were significant at all evaluation time points after treatment. Experimental group had less hospitalization events than Control group in the 12-month evaluation (P=0.015). The Experimental group showed lower depression and anxiety in the 6-month (P=0.006; P=0.019), 12-month (P=0.001; P<0.001) and 5-year (P<0.001, P<0.001) evaluation time points. Significant differences emerged in mania and misadjustment already in the post-treatment evaluation (P=0.009; P<0.001) and were sustained throughout the study (6-month: P=0.006, P<0.001; 12-month: P<0.001, P<0.001; 5-year: P=0.004, P<0.001). After 5-year follow-up, 88.9% of patients in the Control group and 20% of patients in the Experimental group showed persistent affective symptoms and/or difficulties in social-occupational functioning. A combined therapy is long-term effective for patients with refractory bipolar disorder. Suggestions for future research are commented. Published by Elsevier Masson SAS.
Li, Yajin; Chen, Litong; Yuan, Fusong; Li, Yugui; Zhou, Yongsheng; Sun, Yuchun
2017-01-01
This study is to quantitatively evaluate the efficacy of using a non-contact automatic articulating paper dispenser for reducing microbial articulating paper contamination. Articulating papers in four-handed mode, non-four-handed mode, and via an automatic articulating paper dispenser were evaluated. An adenosine triphosphate bioluminescence assay was used to quantitatively measure the relative light unit (RLU) values of the rest unused articulating papers in the same package to detect contamination at 4 time points, and triplicate examinations were performed for all three methods. The RLUs were recorded, compared, and evaluated. For four-handed mode (n = 36), the RLUs at the four time points were 2.44, 32.89, 37.89, and 27.22, with a satisfactory rate of 94%. The RLUs for non-four-handed mode (n = 36) were 2.22, 286.44, 299.44, and 493.56, with a satisfactory rate of 36%. The RLUs for using the automatic dispenser (n = 36) were all 0 with a satisfactory rate of 100%. The satisfactory rates were significantly different among three methods. No significant differences were observed in the satisfactory rates for the four time points samples. Contact by gloved hands can cause severe biological contamination of articulating paper. However, by using standard four-handed mode or a non-contact automatic articulating paper dispenser, contamination can be controlled. PMID:28466846
Using Newsletters to Improve Parents' Communication with Their Early Adolescents
ERIC Educational Resources Information Center
Dworkin, Jodi; Gonzalez, Chris; Gengler, Colleen; Olson, Kathleen
2011-01-01
Two sets of newsletters designed to improve parent-teen communication were distributed at two different time points to 71 parents of seventh and eighth graders across five states. At both points, parents completed an evaluation assessing parent-child communication, parenting practices, the emotional experience of parenting, other parent education…
Lang, Paul Z; Thulasi, Praneetha; Khandelwal, Sumitra S; Hafezi, Farhad; Randleman, J Bradley
2018-05-02
To evaluate the correlation between anterior axial curvature difference maps following corneal cross-linking (CXL) for progressive keratoconus obtained from Scheimpflug-based tomography and Placido-based topography. Between-devices reliability analysis of randomized clinical trial data METHODS: Corneal imaging was collected at a single center institution pre-operatively and at 3, 6, and 12 months post-operatively using Scheimpflug-based tomography (Pentacam, Oculus Inc., Lynnwood, WA) and Scanning-slit, Placido-based topography (Orbscan II, Bausch & Lomb, Rochester, NY) in patients with progressive keratoconus receiving standard protocol CXL (3mW/cm 2 for 30 minutes). Regularization index (RI), absolute maximum keratometry (K Max), and change in (ΔK Max) were compared between the two devices at each time point. 51 eyes from 36 patients were evaluated at all time points. values were significantly different at all time points [56.01±5.3D Scheimpflug vs. 55.04±5.1D scanning-slit pre-operatively (p=0.003); 54.58±5.3D Scheimpflug vs. 53.12±4.9D scanning-slit at 12 months (p<0.0001)] but strongly correlated between devices (r=0.90-0.93) at all time points. The devices were not significantly different at any time point for either ΔK Max or RI but were poorly correlated at all time points (r=0.41-0.53 for ΔK Max, r=0.29-0.48 for RI). At 12 months, 95% LOA was 7.51D for absolute, 8.61D for ΔK Max, and 19.86D for RI. Measurements using Scheimpflug and scanning-slit Placido-based technology are correlated but not interchangeable. Both devices appear reasonable for separately monitoring the cornea's response to CXL; however, caution should be used when comparing results obtained with one measuring technology to the other. Copyright © 2018 Elsevier Inc. All rights reserved.
Dual keel Space Station payload pointing system design and analysis feasibility study
NASA Technical Reports Server (NTRS)
Smagala, Tom; Class, Brian F.; Bauer, Frank H.; Lebair, Deborah A.
1988-01-01
A Space Station attached Payload Pointing System (PPS) has been designed and analyzed. The PPS is responsible for maintaining fixed payload pointing in the presence of disturbance applied to the Space Station. The payload considered in this analysis is the Solar Optical Telescope. System performance is evaluated via digital time simulations by applying various disturbance forces to the Space Station. The PPS meets the Space Station articulated pointing requirement for all disturbances except Shuttle docking and some centrifuge cases.
Long, Jean-Alexandre; Daanen, Vincent; Moreau-Gaudry, Alexandre; Troccaz, Jocelyne; Rambeaud, Jean-Jacques; Descotes, Jean-Luc
2007-11-01
The objective of this study was to determine the added value of real-time three-dimensional (4D) ultrasound guidance of prostatic biopsies on a prostate phantom in terms of the precision of guidance and distribution. A prostate phantom was constructed. A real-time 3D ultrasonograph connected to a transrectal 5.9 MHz volumic transducer was used. Fourteen operators performed 336 biopsies with 2D guidance then 4D guidance according to a 12-biopsy protocol. Biopsy tracts were modelled by segmentation in a 3D ultrasound volume. Specific software allowed visualization of biopsy tracts in the reference prostate and evaluated the zone biopsied. A comparative study was performed to determine the added value of 4D guidance compared to 2D guidance by evaluating the precision of entry points and target points. The distribution was evaluated by measuring the volume investigated and by a redundancy ratio of the biopsy points. The precision of the biopsy protocol was significantly improved by 4D guidance (p = 0.037). No increase of the biopsy volume and no improvement of the distribution of biopsies were observed with 4D compared to 2D guidance. The real-time 3D ultrasound-guided prostate biopsy technique on a phantom model appears to improve the precision and reproducibility of a biopsy protocol, but the distribution of biopsies does not appear to be improved.
Surgical Pathology Resident Rotation Restructuring at a Tertiary Care Academic Center.
Mehr, Chelsea R; Obstfeld, Amrom E; Barrett, Amanda C; Montone, Kathleen T; Schwartz, Lauren E
2017-01-01
Changes in the field of pathology and resident education necessitate ongoing evaluation of residency training. Evolutionary change is particularly important for surgical pathology rotations, which form the core of anatomic pathology training programs. In the past, we organized this rotation based on subjective insight. When faced with the recent need to restructure the rotation, we strove for a more evidence-based process. Our approach involved 2 primary sources of data. We quantified the number of cases and blocks submitted per case type to estimate workload and surveyed residents about the time required to gross specimens in all organ systems. A multidisciplinary committee including faculty, residents, and staff evaluated the results and used the data to model how various changes to the rotation would affect resident workload, turnaround time, and other variables. Finally, we identified rotation structures that equally distributed work and created a point-based system that capped grossing time for residents of different experience. Following implementation, we retrospectively compared turnaround time and duty hour violations before and after these changes and surveyed residents about their experiences with both systems. We evaluated the accuracy of the point-based system by examining grossing times and comparing them to the assigned point values. We found overall improvement in the rotation following the implementation. As there is essentially no literature on the subject of surgical pathology rotation organization, we hope that our experience will provide a road map to improve pathology resident education at other institutions.
Craig, Darren G; Kitto, Laura; Zafar, Sara; Reid, Thomas W D J; Martin, Kirsty G; Davidson, Janice S; Hayes, Peter C; Simpson, Kenneth J
2014-09-01
The innate immune system is profoundly dysregulated in paracetamol (acetaminophen)-induced liver injury. The neutrophil-lymphocyte ratio (NLR) is a simple bedside index with prognostic value in a number of inflammatory conditions. To evaluate the prognostic accuracy of the NLR in patients with significant liver injury following single time-point and staggered paracetamol overdoses. Time-course analysis of 100 single time-point and 50 staggered paracetamol overdoses admitted to a tertiary liver centre. Timed laboratory samples were correlated with time elapsed after overdose or admission, respectively, and the NLR was calculated. A total of 49/100 single time-point patients developed hepatic encephalopathy (HE). Median NLRs were higher at both 72 (P=0.0047) and 96 h after overdose (P=0.0041) in single time-point patients who died or were transplanted. Maximum NLR values by 96 h were associated with increasing HE grade (P=0.0005). An NLR of more than 16.7 during the first 96 h following overdose was independently associated with the development of HE [odds ratio 5.65 (95% confidence interval 1.67-19.13), P=0.005]. Maximum NLR values by 96 h were strongly associated with the requirement for intracranial pressure monitoring (P<0.0001), renal replacement therapy (P=0.0002) and inotropic support (P=0.0005). In contrast, in the staggered overdose cohort, the NLR was not associated with adverse outcomes or death/transplantation either at admission or subsequently. The NLR is a simple test which is strongly associated with adverse outcomes following single time-point, but not staggered, paracetamol overdoses. Future studies should assess the value of incorporating the NLR into existing prognostic and triage indices of single time-point paracetamol overdose.
Magnus, Manya; Herwehe, Jane; Andrews, Laura; Gibson, Laura; Daigrepont, Nathan; De Leon, Jordana M; Hyslop, Newton E; Styron, Steven; Wilcox, Ronald; Kaiser, Michael; Butler, Michael K
2009-02-01
Health information technology (HIT) offers the potential to improve care for persons living with HIV. Provider satisfaction with HIT is essential to realize benefits, yet its evaluation presents challenges. An HIV-specific, electronic clinical management and reporting system was implemented in Louisiana's eight HIV clinics, serving over 7500. A serial cross-sectional survey was administered at three points between April 2002 and July 2005; qualitative methods were used to augment quantitative. Multivariable methods were used to characterize provider satisfaction. The majority of the sample (n = 196; T1 = 105; T2 = 46; T3 = 45) was female (80.0%), between ages of 25 and 50 years (68.3%), frequent providers at that clinic (53.7% more than 4 days per week), and had been at the same clinic for a year or more (85.0%). Improvements in satisfaction were observed in patient tracking ( p < 0.05), distribution of educational materials ( p < 0.04), and belief that electronic systems improve care ( p < 0.05). Provider self-reports of time to complete critical functions decreased for all tasks, two significantly so. Time (in minutes) to find current CD4 count decreased at each time point (mean 3.9 [standard deviation {SD} 5.8], 2.9 [2.3], 2.1 [2.6], p>0.05), current viral load decreased at each time point (mean 4.0 [SD 5.6], 2.9 [2.5], 1.8 [2.6], p = 0.08], current antiretroviral status decreased at each time point (mean 3.9 [SD 4.7], 2.9 [3.7], 1.5 [1.1], p < 0.04), history of antiretroviral use decreased at each time point (mean 15.1 [SD 21.9], 6.0 [5.4], 5.4 [7.2], p < 0.04]. Time savings were realized, averaging 16.1 minutes per visit ( p < 0.04). Providers were satisfied with HIT in multiple domains, and significant time savings were realized.
Gómez, María José; Herrera, Sonia; Solé, David; García-Calvo, Eloy; Fernández-Alba, Amadeo R
2012-03-15
This study aims to assess the occurrence, fate and temporal and spatial distribution of anthropogenic contaminants in a river subjected to different pressures (industrial, agricultural, wastewater discharges). For this purpose, the Henares River basin (central Spain) can be considered a representative basin within a continental Mediterranean climate. As the studied river runs through several residential, industrial and agricultural areas, it would be expected that the chemical water quality is modified along its course. Thereby the selection of sampling points and timing of sample collection are critical factors in the monitoring of a river basin. In this study, six different monitoring campaigns were performed in 2010 and contaminants were measured at the effluent point of the main wastewater treatment plant (WWTP) in the river basin and at five different points upstream and downstream from the WWTP emission point. The target compounds evaluated were personal care products (PCPs), polycyclic aromatic hydrocarbons (PAHs) and pesticides. Results show that the river is clearly influenced by wastewater discharges and also by its proximity to agricultural areas. The contaminants detected at higher concentrations were the PCPs. The spatial distribution of the contaminants indicates that the studied contaminants persist along the river. In the time period studied no great seasonal variations of PCPs at the river collection points were observed. In contrast, a temporal trend of pesticides and PAHs was observed. Besides the target compounds, other new contaminants were identified and evaluated in the water samples, some of them being investigated for the first time in the aquatic environment. The behaviour of three important transformation products was also evaluated: 9,10-anthracenodione, galaxolide-lactone and 4-amino-musk xylene. These were found at higher concentrations than their parent compounds, indicating the significance of including the study of transformation products in the monitoring programmes. Copyright © 2012 Elsevier B.V. All rights reserved.
Evaluation of a time efficient immunization strategy for anti-PAH antibody development
Li, Xin; Kaattari, Stephen L.; Vogelbein, Mary Ann; Unger, Michael A.
2016-01-01
The development of monoclonal antibodies (mAb) with affinity to small molecules can be a time-consuming process. To evaluate shortening the time for mAb production, we examined mouse antisera at different time points post-immunization to measure titer and to evaluate the affinity to the immunogen PBA (pyrene butyric acid). Fusions were also conducted temporally to evaluate antibody production success at various time periods. We produced anti-PBA antibodies 7 weeks post-immunization and selected for anti-PAH reactivity during the hybridoma screening process. Moreover, there were no obvious sensitivity differences relative to antibodies screened from a more traditional 18 week schedule. Our results demonstrate a more time efficient immunization strategy for anti-PAH antibody development that may be applied to other small molecules. PMID:27282486
NASA Astrophysics Data System (ADS)
Cassan, Arnaud
2017-07-01
The exoplanet detection rate from gravitational microlensing has grown significantly in recent years thanks to a great enhancement of resources and improved observational strategy. Current observatories include ground-based wide-field and/or robotic world-wide networks of telescopes, as well as space-based observatories such as satellites Spitzer or Kepler/K2. This results in a large quantity of data to be processed and analysed, which is a challenge for modelling codes because of the complexity of the parameter space to be explored and the intensive computations required to evaluate the models. In this work, I present a method that allows to compute the quadrupole and hexadecapole approximations of the finite-source magnification with more efficiency than previously available codes, with routines about six times and four times faster, respectively. The quadrupole takes just about twice the time of a point-source evaluation, which advocates for generalizing its use to large portions of the light curves. The corresponding routines are available as open-source python codes.
Fink, Ericka L; Berger, Rachel P; Clark, Robert S B; Watson, R Scott; Angus, Derek C; Panigrahy, Ashok; Richichi, Rudolph; Callaway, Clifton W; Bell, Michael J; Mondello, Stefania; Hayes, Ronald L; Kochanek, Patrick M
2016-04-01
Brain injury is the leading cause of morbidity and death following pediatric cardiac arrest. Serum biomarkers of brain injury may assist in outcome prognostication. The objectives of this study were to evaluate the properties of serum ubiquitin carboxyl-terminal esterase-L1 (UCH-L1) and glial fibrillary acidic protein (GFAP) to classify outcome in pediatric cardiac arrest. Single center prospective study. Serum biomarkers were measured at 2 time points during the initial 72 h in children after cardiac arrest (n=19) and once in healthy children (controls, n=43). We recorded demographics and details of the cardiac arrest and resuscitation. We determined the associations between serum biomarker concentrations and Pediatric Cerebral Performance Category (PCPC) at 6 months (favorable (PCPC 1-3) or unfavorable (PCPC 4-6)). The initial assessment (time point 1) occurred at a median (IQR) of 10.5 (5.5-17.0)h and the second assessment (time point 2) at 59.0 (54.5-65.0)h post-cardiac arrest. Serum UCH-L1 was higher among children following cardiac arrest than among controls at both time points (p<0.05). Serum GFAP in subjects with unfavorable outcome was higher at time point 2 than in controls (p<0.05). Serum UCH-L1 at time point 1 (AUC 0.782) and both UCH-L1 and GFAP at time point 2 had good classification accuracy for outcome (AUC 0.822 and 0.796), p<0.05 for all. Preliminary data suggest that serum UCH-L1 and GFAP may be of use to prognosticate outcome after pediatric cardiac arrest at clinically-relevant time points and should be validated prospectively. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Fink, Ericka L; Berger, Rachel P; Clark, Robert SB; Watson, R. Scott; Angus, Derek C; Panigrahy, Ashok; Richichi, Rudolph; Callaway, Clifton W; Bell, Michael J; Mondello, Stefania; Hayes, Ronald L.; Kochanek, Patrick M
2016-01-01
Introduction Brain injury is the leading cause of morbidity and death following pediatric cardiac arrest. Serum biomarkers of brain injury may assist in outcome prognostication. The objectives of this study were to evaluate the properties of serum ubiquitin carboxyl-terminal esterase-L1 (UCH-L1) and glial fibrillary acidic protein (GFAP) to classify outcome in pediatric cardiac arrest. Methods Single center prospective study. Serum biomarkers were measured at 2 time points during the initial 72 h in children after cardiac arrest (n=19) and once in healthy children (controls, n=43). We recorded demographics and details of the cardiac arrest and resuscitation. We determined the associations between serum biomarker concentrations and Pediatric Cerebral Performance Category (PCPC) at 6 months (favorable (PCPC 1–3) or unfavorable (PCPC 4–6)). Results The initial assessment (time point 1) occurred at a median (IQR) of 10.5 (5.5–17.0) h and the second assessment (time point 2) at 59.0 (54.5–65.0) h post-cardiac arrest. Serum UCH-L1 was higher among children following cardiac arrest than among controls at both time points (p<0.05). Serum GFAP in subjects with unfavorable outcome was higher at time point 2 than in controls (p<0.05). Serum UCH-L1 at time point 1 (AUC 0.782) and both UCH-L1 and GFAP at time point 2 had good classification accuracy for outcome (AUC 0.822 and 0.796), p<0.05 for all. Conclusion Preliminary data suggest that serum UCH-L1 and GFAP may be of use to prognosticate outcome after pediatric cardiac arrest at clinically-relevant time points and should be validated prospectively. PMID:26855294
Refahi, Soheila; Pourissa, Masoud; Zirak, Mohammad Reza; Hadadi, GholamHassan
2015-01-01
To evaluate the ability of glycyrrhizic acid (GLA) to reduce the tumor necrosis factor α (TNF-α), release on messenger ribonucleic acid (mRNA) and protein production in the lungs using GLA in response to irradiation were studied. The animals were divided into four groups: No treatment (NT group), GLA treatment only (GLA group), irradiation only (XRT group), and GLA treatment plus irradiation (GLA/XRT group). Rats were killed at different time points. Real-time reverse transcriptase polymerase chain reaction (RT-PCR) was used to evaluate the mRNA expression of TNF-α in the lungs (compared with non-irradiated lungs). An enzyme-linked immunosorbant assay (ELISA) assay was used to measure the TNF-α protein level. The TNF-α mRNA expression in the lungs of the XRT rats was clearly higher at all-time points compared to the NT rats. The TNF-α mRNA expression in the lungs of the GLA/XRT rats was lower at all-time points compared to the XRT rats. Release of the TNF-α on protein level in the lungs of the XRT rats increased at all-time points compared to the NT rats. In contrast to the XRT rats, the lungs of the GLA/XRT rats revealed a reduction on TNF-α protein level at 6 h after irradiation. This study has clearly showed the immediate down-regulation of the TNF-α mRNA and protein production in the lungs using GLA in response to irradiation.
Refahi, Soheila; Pourissa, Masoud; Zirak, Mohammad Reza; Hadadi, GholamHassan
2015-01-01
To evaluate the ability of glycyrrhizic acid (GLA) to reduce the tumor necrosis factor α (TNF-α), release on messenger ribonucleic acid (mRNA) and protein production in the lungs using GLA in response to irradiation were studied. The animals were divided into four groups: No treatment (NT group), GLA treatment only (GLA group), irradiation only (XRT group), and GLA treatment plus irradiation (GLA/XRT group). Rats were killed at different time points. Real-time reverse transcriptase polymerase chain reaction (RT-PCR) was used to evaluate the mRNA expression of TNF-α in the lungs (compared with non-irradiated lungs). An enzyme-linked immunosorbant assay (ELISA) assay was used to measure the TNF-α protein level. The TNF-α mRNA expression in the lungs of the XRT rats was clearly higher at all-time points compared to the NT rats. The TNF-α mRNA expression in the lungs of the GLA/XRT rats was lower at all-time points compared to the XRT rats. Release of the TNF-α on protein level in the lungs of the XRT rats increased at all-time points compared to the NT rats. In contrast to the XRT rats, the lungs of the GLA/XRT rats revealed a reduction on TNF-α protein level at 6 h after irradiation. This study has clearly showed the immediate down-regulation of the TNF-α mRNA and protein production in the lungs using GLA in response to irradiation. PMID:26170556
Historical Data Analysis of Hospital Discharges Related to the Amerithrax Attack in Florida
Burke, Lauralyn K.; Brown, C. Perry; Johnson, Tammie M.
2016-01-01
Interrupted time-series analysis (ITSA) can be used to identify, quantify, and evaluate the magnitude and direction of an event on the basis of time-series data. This study evaluates the impact of the bioterrorist anthrax attacks (“Amerithrax”) on hospital inpatient discharges in the metropolitan statistical area of Palm Beach, Broward, and Miami-Dade counties in the fourth quarter of 2001. Three statistical methods—standardized incidence ratio (SIR), segmented regression, and an autoregressive integrated moving average (ARIMA)—were used to determine whether Amerithrax influenced inpatient utilization. The SIR found a non–statistically significant 2 percent decrease in hospital discharges. Although the segmented regression test found a slight increase in the discharge rate during the fourth quarter, it was also not statistically significant; therefore, it could not be attributed to Amerithrax. Segmented regression diagnostics preparing for ARIMA indicated that the quarterly data time frame was not serially correlated and violated one of the assumptions for the use of the ARIMA method and therefore could not properly evaluate the impact on the time-series data. Lack of data granularity of the time frames hindered the successful evaluation of the impact by the three analytic methods. This study demonstrates that the granularity of the data points is as important as the number of data points in a time series. ITSA is important for the ability to evaluate the impact that any hazard may have on inpatient utilization. Knowledge of hospital utilization patterns during disasters offer healthcare and civic professionals valuable information to plan, respond, mitigate, and evaluate any outcomes stemming from biothreats. PMID:27843420
Survival of Salmonella enterica in poultry feed is strain dependent
Andino, Ana; Pendleton, Sean; Zhang, Nan; Chen, Wei; Critzer, Faith; Hanning, Irene
2014-01-01
Feed components have low water activity, making bacterial survival difficult. The mechanisms of Salmonella survival in feed and subsequent colonization of poultry are unknown. The purpose of this research was to compare the ability of Salmonella serovars and strains to survive in broiler feed and to evaluate molecular mechanisms associated with survival and colonization by measuring the expression of genes associated with colonization (hilA, invA) and survival via fatty acid synthesis (cfa, fabA, fabB, fabD). Feed was inoculated with 1 of 15 strains of Salmonella enterica consisting of 11 serovars (Typhimurium, Enteriditis, Kentucky, Seftenburg, Heidelberg, Mbandanka, Newport, Bairely, Javiana, Montevideo, and Infantis). To inoculate feed, cultures were suspended in PBS and survival was evaluated by plating samples onto XLT4 agar plates at specific time points (0 h, 4 h, 8 h, 24 h, 4 d, and 7 d). To evaluate gene expression, RNA was extracted from the samples at the specific time points (0, 4, 8, and 24 h) and gene expression measured with real-time PCR. The largest reduction in Salmonella occurred at the first and third sampling time points (4 h and 4 d) with the average reductions being 1.9 and 1.6 log cfu per g, respectively. For the remaining time points (8 h, 24 h, and 7 d), the average reduction was less than 1 log cfu per g (0.6, 0.4, and 0.6, respectively). Most strains upregulated cfa (cyclopropane fatty acid synthesis) within 8 h, which would modify the fluidity of the cell wall to aid in survival. There was a weak negative correlation between survival and virulence gene expression indicating downregulation to focus energy on other gene expression efforts such as survival-related genes. These data indicate the ability of strains to survive over time in poultry feed was strain dependent and that upregulation of cyclopropane fatty acid synthesis and downregulation of virulence genes were associated with a response to desiccation stress. PMID:24570467
Survival of Salmonella enterica in poultry feed is strain dependent.
Andino, Ana; Pendleton, Sean; Zhang, Nan; Chen, Wei; Critzer, Faith; Hanning, Irene
2014-02-01
Feed components have low water activity, making bacterial survival difficult. The mechanisms of Salmonella survival in feed and subsequent colonization of poultry are unknown. The purpose of this research was to compare the ability of Salmonella serovars and strains to survive in broiler feed and to evaluate molecular mechanisms associated with survival and colonization by measuring the expression of genes associated with colonization (hilA, invA) and survival via fatty acid synthesis (cfa, fabA, fabB, fabD). Feed was inoculated with 1 of 15 strains of Salmonella enterica consisting of 11 serovars (Typhimurium, Enteriditis, Kentucky, Seftenburg, Heidelberg, Mbandanka, Newport, Bairely, Javiana, Montevideo, and Infantis). To inoculate feed, cultures were suspended in PBS and survival was evaluated by plating samples onto XLT4 agar plates at specific time points (0 h, 4 h, 8 h, 24 h, 4 d, and 7 d). To evaluate gene expression, RNA was extracted from the samples at the specific time points (0, 4, 8, and 24 h) and gene expression measured with real-time PCR. The largest reduction in Salmonella occurred at the first and third sampling time points (4 h and 4 d) with the average reductions being 1.9 and 1.6 log cfu per g, respectively. For the remaining time points (8 h, 24 h, and 7 d), the average reduction was less than 1 log cfu per g (0.6, 0.4, and 0.6, respectively). Most strains upregulated cfa (cyclopropane fatty acid synthesis) within 8 h, which would modify the fluidity of the cell wall to aid in survival. There was a weak negative correlation between survival and virulence gene expression indicating downregulation to focus energy on other gene expression efforts such as survival-related genes. These data indicate the ability of strains to survive over time in poultry feed was strain dependent and that upregulation of cyclopropane fatty acid synthesis and downregulation of virulence genes were associated with a response to desiccation stress.
Teacher Evaluation: Principals' Insights and Suggestions for Improvement
ERIC Educational Resources Information Center
Kersten, Thomas A.; Israel, Marla S.
2005-01-01
In the twenty-first century, school improvement is the focal point for educational leadership, in which the school building administrator is recognized as the catalyst for this necessary improvement. Within the area of teacher evaluation, the evaluation tools, along with the amount of time, format, and feedback, have changed dramatically from the…
USDA-ARS?s Scientific Manuscript database
AnnAGNPS (Annualized Agricultural Non-Point Source Pollution Model) is a system of computer models developed to predict non-point source pollutant loadings within agricultural watersheds. It contains a daily time step distributed parameter continuous simulation surface runoff model designed to assis...
Dew point fast measurement in organic vapor mixtures using quartz resonant sensor
NASA Astrophysics Data System (ADS)
Nie, Jing; Liu, Jia; Meng, Xiaofeng
2017-01-01
A fast dew point sensor has been developed for organic vapor mixtures by using the quartz crystal with sensitive circuits. The sensor consists of the quartz crystal and a cooler device. Proactive approach is taken to produce condensation on the surface of the quartz crystal, and it will lead to a change in electrical features of the quartz crystal. The cessation of oscillation was measured because this phenomenon is caused by dew condensation. Such a phenomenon can be used to detect the dew point. This method exploits the high sensitivity of the quartz crystal but without frequency measurement and also retains the stability of the resonant circuit. It is strongly anti-interfered. Its performance was evaluated with acetone-methanol mixtures under different pressures. The results were compared with the dew points predicted from the universal quasi-chemical equation to evaluate the performance of the proposed sensor. Though the maximum deviations of the sensor are less than 1.1 °C, it still has a fast response time with a recovery time of less than 10 s, providing an excellent dehumidifying performance.
Dew point fast measurement in organic vapor mixtures using quartz resonant sensor.
Nie, Jing; Liu, Jia; Meng, Xiaofeng
2017-01-01
A fast dew point sensor has been developed for organic vapor mixtures by using the quartz crystal with sensitive circuits. The sensor consists of the quartz crystal and a cooler device. Proactive approach is taken to produce condensation on the surface of the quartz crystal, and it will lead to a change in electrical features of the quartz crystal. The cessation of oscillation was measured because this phenomenon is caused by dew condensation. Such a phenomenon can be used to detect the dew point. This method exploits the high sensitivity of the quartz crystal but without frequency measurement and also retains the stability of the resonant circuit. It is strongly anti-interfered. Its performance was evaluated with acetone-methanol mixtures under different pressures. The results were compared with the dew points predicted from the universal quasi-chemical equation to evaluate the performance of the proposed sensor. Though the maximum deviations of the sensor are less than 1.1 °C, it still has a fast response time with a recovery time of less than 10 s, providing an excellent dehumidifying performance.
Barrio, Javier; Errando, Carlos L; García-Ramón, Jaime; Sellés, Rafael; San Miguel, Guillermo; Gallego, Juan
2017-11-01
To evaluate the influence of neuromuscular blockade (NMB) on surgical conditions during low-pressure pneumoperitoneum (8mmHg) laparoscopic cholecystectomy (LC), while comparing moderate and deep NMB. Secondary objective was to evaluate if surgical conditions during low-pressure pneumoperitoneum LC performed with deep NMB could be comparable to those provided during standard-pressure pneumoperitoneum (12mmHg) LC. Prospective, randomized, blinded clinical trial. Operating room. Ninety ASA 1-2 patients scheduled for elective LC. Patients were allocated into 3 groups: Group 1: low-pressure pneumoperitoneum with moderate-NMB (1-3 TOF), Group 2: low-pressure pneumoperitoneum with deep-NMB (1-5 PTC) and Group 3: standard pneumoperitoneum (12mmHg). Rocuronium was used to induce NMB and acceleromiography was used for NMB monitoring (TOF-Watch-SX). Three experienced surgeons evaluated surgical conditions using a four-step scale at three time-points: surgical field exposure, dissection of the gallbladder and extraction/closure. Low-pressure pneumoperitoneum (Group 1 vs. 2): good conditions: 96.7 vs. 96.7%, 90 vs. 80% and 89.6 vs. 92.3%, respectively for the time-points, p>0.05. No differences in optimal surgical conditions were observed between the groups. Surgery completion at 8mmHg pneumoperitoneum: 96.7 vs. 86.7%, p=0.353. Standard-pressure pneumoperitoneum vs. low-pressure pneumoperitoneum with deep NMB (Group 3 vs. 2): good conditions: 100% in Group 3 for the three time-points (p=0.024 vs. Group 2 at dissection of the gallbladder). Significantly greater percentage of optimal conditions during standard-pressure pneumoperitoneum LC at the three time points of evaluation. The depth of NMB was found not to be decisive neither in the improvement of surgical conditions nor in the completion of low-pressure pneumoperitoneum LC performed by experienced surgeons. Surgical conditions were considered better with a standard-pressure pneumoperitoneum, regardless of the depth of NMB, than during low-pressure pneumoperitoneum with deep NMB. Copyright © 2017 Elsevier Inc. All rights reserved.
Computer-assisted recording of tensile tests for the evaluation of serrated flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weinhandl, H.; Mitter, F.; Bernt, W.
1994-12-01
In a previous paper the authors pointed out the difficulties which arise in the evaluation of serrated flow curves when the applied tensile strain rates are just above normal''. The recording system of tensile testing machines which were built, say, twenty years ago, are not capable of recording the full size of the load drops due to the inertia of the recording pen. This handicap was then overcome by establishing correction factors which were determined from recording a small number of load drops with an oscilloscope. Modern testing machines are equipped with digital recording. The disadvantage of the common systemmore » is, however, their limited capacity, so that not enough space for data points is available. Consequently, the time intervals between data points are of the order of tenths of seconds. It will become obvious from the present results that such a time interval is too large for recording a correct serration size. This report is concerned with the recording of complete load-extension relations during tensile tests using a computer which is capable of storing the data at sufficiently small time intervals.« less
Integrated evaluation of visually induced motion sickness in terms of autonomic nervous regulation.
Kiryu, Tohru; Tada, Gen; Toyama, Hiroshi; Iijima, Atsuhiko
2008-01-01
To evaluate visually-induced motion sickness, we integrated subjective and objective responses in terms of autonomic nervous regulation. Twenty-seven subjects viewed a 2-min-long first-person-view video section five times (total 10 min) continuously. Measured biosignals, the RR interval, respiration, and blood pressure, were used to estimate the indices related to autonomic nervous activity (ANA). Then we determined the trigger points and some sensation sections based on the time-varying behavior of ANA-related indices. We found that there was a suitable combination of biosignals to present the symptoms of visually-induced motion sickness. Based on the suitable combination, integrating trigger points and subjective scores allowed us to represent the time-distribution of subjective responses during visual exposure, and helps us to understand what types of camera motions will cause visually-induced motion sickness.
Canali, Inesângela; Petersen Schmidt Rosito, Letícia; Siliprandi, Bruno; Giugno, Cláudia; Selaimen da Costa, Sady
The diagnosis of Eustachian tube dysfunctions is essential for better understanding of the pathogenesis of chronic otitis media. A series of tests to assess tube function are described in the literature; however, they are methodologically heterogeneous, with differences ranging from application protocols to standardization of tests and their results. To evaluate the variation in middle ear pressure in patients with tympanic membrane retraction and in normal patients during tube function tests, as well as to evaluate intra-individual variation between these tests. An observational, contemporary, cross-sectional study was conducted, in which the factor under study was the variation in middle ear pressure during tube function tests (Valsalva maneuver, sniff test, Toynbee maneuver) in healthy patients and in patients with mild and moderate/severe tympanic retraction. A total of 38 patients (76 ears) were included in the study. Patients underwent tube function tests at two different time points to determine pressure measurements after each maneuver. Statistical analysis was performed using SPSS software, version 18.0, considering p-values <0.05 as statistically significant. Mean (standard deviation) age was 11 (2.72) years; 55.3% of patients were male and 44.7% female. The prevalence of type A tympanogram was higher among participants with healthy ears and those with mild retraction, whereas type C tympanograms were more frequent in the moderate/severe retraction group. An increase in middle ear pressure was observed during the Valsalva maneuver at the first time point evaluated in all three groups of ears (p=0.012). The variation in pressure was not significant either for the sniff test or for the Toynbee maneuver at the two time points evaluated (p≥0.05). Agreement between measurements obtained at the two different time points was weak to moderate for all tests in all three groups of ears, and the variations in discrepancy between measurements were higher in ears with moderate/severe tympanic retraction. In this study population, the mean pressure in the middle ear showed significant variation only during the Valsalva maneuver at the first time point evaluated in the three groups of ears. Normal ears and those with mild retraction behaved similarly in all tests. The tested maneuvers exhibited weak to moderate intra-individual variation, with the greatest variation occurring in ears with moderate/severe retraction. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
A Novel Real-Time Reference Key Frame Scan Matching Method.
Mohamed, Haytham; Moussa, Adel; Elhabiby, Mohamed; El-Sheimy, Naser; Sesay, Abu
2017-05-07
Unmanned aerial vehicles represent an effective technology for indoor search and rescue operations. Typically, most indoor missions' environments would be unknown, unstructured, and/or dynamic. Navigation of UAVs in such environments is addressed by simultaneous localization and mapping approach using either local or global approaches. Both approaches suffer from accumulated errors and high processing time due to the iterative nature of the scan matching method. Moreover, point-to-point scan matching is prone to outlier association processes. This paper proposes a low-cost novel method for 2D real-time scan matching based on a reference key frame (RKF). RKF is a hybrid scan matching technique comprised of feature-to-feature and point-to-point approaches. This algorithm aims at mitigating errors accumulation using the key frame technique, which is inspired from video streaming broadcast process. The algorithm depends on the iterative closest point algorithm during the lack of linear features which is typically exhibited in unstructured environments. The algorithm switches back to the RKF once linear features are detected. To validate and evaluate the algorithm, the mapping performance and time consumption are compared with various algorithms in static and dynamic environments. The performance of the algorithm exhibits promising navigational, mapping results and very short computational time, that indicates the potential use of the new algorithm with real-time systems.
Amundson, Courtney L.; Royle, J. Andrew; Handel, Colleen M.
2014-01-01
Imperfect detection during animal surveys biases estimates of abundance and can lead to improper conclusions regarding distribution and population trends. Farnsworth et al. (2005) developed a combined distance-sampling and time-removal model for point-transect surveys that addresses both availability (the probability that an animal is available for detection; e.g., that a bird sings) and perceptibility (the probability that an observer detects an animal, given that it is available for detection). We developed a hierarchical extension of the combined model that provides an integrated analysis framework for a collection of survey points at which both distance from the observer and time of initial detection are recorded. Implemented in a Bayesian framework, this extension facilitates evaluating covariates on abundance and detection probability, incorporating excess zero counts (i.e. zero-inflation), accounting for spatial autocorrelation, and estimating population density. Species-specific characteristics, such as behavioral displays and territorial dispersion, may lead to different patterns of availability and perceptibility, which may, in turn, influence the performance of such hierarchical models. Therefore, we first test our proposed model using simulated data under different scenarios of availability and perceptibility. We then illustrate its performance with empirical point-transect data for a songbird that consistently produces loud, frequent, primarily auditory signals, the Golden-crowned Sparrow (Zonotrichia atricapilla); and for 2 ptarmigan species (Lagopus spp.) that produce more intermittent, subtle, and primarily visual cues. Data were collected by multiple observers along point transects across a broad landscape in southwest Alaska, so we evaluated point-level covariates on perceptibility (observer and habitat), availability (date within season and time of day), and abundance (habitat, elevation, and slope), and included a nested point-within-transect and park-level effect. Our results suggest that this model can provide insight into the detection process during avian surveys and reduce bias in estimates of relative abundance but is best applied to surveys of species with greater availability (e.g., breeding songbirds).
Selective Data Acquisition in NMR. The Quantification of Anti-phase Scalar Couplings
NASA Astrophysics Data System (ADS)
Hodgkinson, P.; Holmes, K. J.; Hore, P. J.
Almost all time-domain NMR experiments employ "linear sampling," in which the NMR response is digitized at equally spaced times, with uniform signal averaging. Here, the possibilities of nonlinear sampling are explored using anti-phase doublets in the indirectly detected dimensions of multidimensional COSY-type experiments as an example. The Cramér-Rao lower bounds are used to evaluate and optimize experiments in which the sampling points, or the extent of signal averaging at each point, or both, are varied. The optimal nonlinear sampling for the estimation of the coupling constant J, by model fitting, turns out to involve just a few key time points, for example, at the first node ( t= 1/ J) of the sin(π Jt) modulation. Such sparse sampling patterns can be used to derive more practical strategies, in which the sampling or the signal averaging is distributed around the most significant time points. The improvements in the quantification of NMR parameters can be quite substantial especially when, as is often the case for indirectly detected dimensions, the total number of samples is limited by the time available.
NASA Astrophysics Data System (ADS)
Yokoyama, Yoshiaki; Kim, Minseok; Arai, Hiroyuki
At present, when using space-time processing techniques with multiple antennas for mobile radio communication, real-time weight adaptation is necessary. Due to the progress of integrated circuit technology, dedicated processor implementation with ASIC or FPGA can be employed to implement various wireless applications. This paper presents a resource and performance evaluation of the QRD-RLS systolic array processor based on fixed-point CORDIC algorithm with FPGA. In this paper, to save hardware resources, we propose the shared architecture of a complex CORDIC processor. The required precision of internal calculation, the circuit area for the number of antenna elements and wordlength, and the processing speed will be evaluated. The resource estimation provides a possible processor configuration with a current FPGA on the market. Computer simulations assuming a fading channel will show a fast convergence property with a finite number of training symbols. The proposed architecture has also been implemented and its operation was verified by beamforming evaluation through a radio propagation experiment.
Hauser, Susan E; Demner-Fushman, Dina; Jacobs, Joshua L; Humphrey, Susanne M; Ford, Glenn; Thoma, George R
2007-01-01
To evaluate: (1) the effectiveness of wireless handheld computers for online information retrieval in clinical settings; (2) the role of MEDLINE in answering clinical questions raised at the point of care. A prospective single-cohort study: accompanying medical teams on teaching rounds, five internal medicine residents used and evaluated MD on Tap, an application for handheld computers, to seek answers in real time to clinical questions arising at the point of care. All transactions were stored by an intermediate server. Evaluators recorded clinical scenarios and questions, identified MEDLINE citations that answered the questions, and submitted daily and summative reports of their experience. A senior medical librarian corroborated the relevance of the selected citation to each scenario and question. Evaluators answered 68% of 363 background and foreground clinical questions during rounding sessions using a variety of MD on Tap features in an average session length of less than four minutes. The evaluator, the number and quality of query terms, the total number of citations found for a query, and the use of auto-spellcheck significantly contributed to the probability of query success. Handheld computers with Internet access are useful tools for healthcare providers to access MEDLINE in real time. MEDLINE citations can answer specific clinical questions when several medical terms are used to form a query. The MD on Tap application is an effective interface to MEDLINE in clinical settings, allowing clinicians to quickly find relevant citations.
Hauser, Susan E.; Demner-Fushman, Dina; Jacobs, Joshua L.; Humphrey, Susanne M.; Ford, Glenn; Thoma, George R.
2007-01-01
Objective To evaluate: (1) the effectiveness of wireless handheld computers for online information retrieval in clinical settings; (2) the role of MEDLINE® in answering clinical questions raised at the point of care. Design A prospective single-cohort study: accompanying medical teams on teaching rounds, five internal medicine residents used and evaluated MD on Tap, an application for handheld computers, to seek answers in real time to clinical questions arising at the point of care. Measurements All transactions were stored by an intermediate server. Evaluators recorded clinical scenarios and questions, identified MEDLINE citations that answered the questions, and submitted daily and summative reports of their experience. A senior medical librarian corroborated the relevance of the selected citation to each scenario and question. Results Evaluators answered 68% of 363 background and foreground clinical questions during rounding sessions using a variety of MD on Tap features in an average session length of less than four minutes. The evaluator, the number and quality of query terms, the total number of citations found for a query, and the use of auto-spellcheck significantly contributed to the probability of query success. Conclusion Handheld computers with Internet access are useful tools for healthcare providers to access MEDLINE in real time. MEDLINE citations can answer specific clinical questions when several medical terms are used to form a query. The MD on Tap application is an effective interface to MEDLINE in clinical settings, allowing clinicians to quickly find relevant citations. PMID:17712085
THE NEW ENLISTED EVALUATION SYSTEM: DID THE AIR FORCE GET IT CORRECT THIS TIME
2015-10-01
faced a two-fold problem - excessive manning promoted through the war along with an increased use of contractors for maintenance and support. This...concept to standardize board promotion methods .38 A three-judge panel scored each package using a 10-point scale on ½-point increments. If the three...rounding methods were changed to remove inequities. The original methods rounded up or down to the nearest whole percentage point, but this change
Brückner, Hans-Peter; Spindeldreier, Christian; Blume, Holger
2013-01-01
A common approach for high accuracy sensor fusion based on 9D inertial measurement unit data is Kalman filtering. State of the art floating-point filter algorithms differ in their computational complexity nevertheless, real-time operation on a low-power microcontroller at high sampling rates is not possible. This work presents algorithmic modifications to reduce the computational demands of a two-step minimum order Kalman filter. Furthermore, the required bit-width of a fixed-point filter version is explored. For evaluation real-world data captured using an Xsens MTx inertial sensor is used. Changes in computational latency and orientation estimation accuracy due to the proposed algorithmic modifications and fixed-point number representation are evaluated in detail on a variety of processing platforms enabling on-board processing on wearable sensor platforms.
Beekman, Christopher R.; Matta, Murali K.; Thomas, Christopher D.; Mohammad, Adil; Stewart, Sharron; Xu, Lin; Chockalingam, Ashok; Shea, Katherine; Sun, Dajun; Jiang, Wenlei; Patel, Vikram; Rouse, Rodney
2017-01-01
Relative biodistribution of FDA-approved innovator and generic sodium ferric gluconate (SFG) drug products was investigated to identify differences in tissue distribution of iron after intravenous dosing to rats. Three equal cohorts of 42 male Sprague-Dawley rats were created with each cohort receiving one of three treatments: (1) the innovator SFG product dosed intravenously at a concentration of 40 mg/kg; (2) the generic SFG product dosed intravenously at a concentration of 40 mg/kg; (3) saline dosed intravenously at equivalent volume to SFG products. Sampling time points were 15 min, 1 h, 8 h, 1 week, two weeks, four weeks, and six weeks post-treatment. Six rats from each group were sacrificed at each time point. Serum, femoral bone marrow, lungs, brain, heart, kidneys, liver, and spleen were harvested and evaluated for total iron concentration by ICP-MS. The ICP-MS analytical method was validated with linearity, range, accuracy, and precision. Results were determined for mean iron concentrations (µg/g) and mean total iron (whole tissue) content (µg/tissue) for each tissue of all groups at each time point. A percent of total distribution to each tissue was calculated for both products. At any given time point, the overall percent iron concentration distribution did not vary between the two SFG drugs by more than 7% in any tissue. Overall, this study demonstrated similar tissue biodistribution for the two SFG products in the examined tissues. PMID:29283393
Rueda, Janice M.; Khosla, Pramod
2013-01-01
The effects of breakfast type on body weight and blood lipids were evaluated in university freshman. Seventy-three subjects were instructed to consume a breakfast with eggs (Egg Breakfast, EB, n = 39) or without (Non-Egg Breakfast, NEB, n = 34), five times/week for 14 weeks. Breakfast composition, anthropometric measurements and blood lipids were measured at multiple times. During the study, mean weight change was 1.6 ± 5.3 lbs (0.73 ± 2.41 kg), but there was no difference between groups. Both groups consumed similar calories for breakfast at all time-points. The EB group consumed significantly more calories at breakfast from protein, total fat and saturated fat, but significantly fewer calories from carbohydrate at every time-point. Cholesterol consumption at breakfast in the EB group was significantly higher than the NEB group at all time points. Breakfast food choices (other than eggs) were similar between groups. Blood lipids were similar between groups at all time points, indicating that the additional 400 mg/day of dietary cholesterol did not negatively impact blood lipids. PMID:24352089
NASA Astrophysics Data System (ADS)
Kim, Byung Chan; Park, Seong-Ook
In order to determine exposure compliance with the electromagnetic fields from a base station's antenna in the far-field region, we should calculate the spatially averaged field value in a defined space. This value is calculated based on the measured value obtained at several points within the restricted space. According to the ICNIRP guidelines, at each point in the space, the reference levels are averaged over any 6min (from 100kHz to 10GHz) for the general public. Therefore, the more points we use, the longer the measurement time becomes. For practical application, it is very advantageous to spend less time for measurement. In this paper, we analyzed the difference of average values between 6min and lesser periods and compared it with the standard uncertainty for measurement drift. Based on the standard deviation from the 6min averaging value, the proposed minimum averaging time is 1min.
Puelacher, Christian; Wagener, Max; Abächerli, Roger; Honegger, Ursina; Lhasam, Nundsin; Schaerli, Nicolas; Prêtre, Gil; Strebel, Ivo; Twerenbold, Raphael; Boeddinghaus, Jasper; Nestelberger, Thomas; Rubini Giménez, Maria; Hillinger, Petra; Wildi, Karin; Sabti, Zaid; Badertscher, Patrick; Cupa, Janosch; Kozhuharov, Nikola; du Fay de Lavallaz, Jeanne; Freese, Michael; Roux, Isabelle; Lohrmann, Jens; Leber, Remo; Osswald, Stefan; Wild, Damian; Zellweger, Michael J; Mueller, Christian; Reichlin, Tobias
2017-07-01
Exercise ECG stress testing is the most widely available method for evaluation of patients with suspected myocardial ischemia. Its major limitation is the relatively poor accuracy of ST-segment changes regarding ischemia detection. Little is known about the optimal method to assess ST-deviations. A total of 1558 consecutive patients undergoing bicycle exercise stress myocardial perfusion imaging (MPI) were enrolled. Presence of inducible myocardial ischemia was adjudicated using MPI results. The diagnostic value of ST-deviations for detection of exercise-induced myocardial ischemia was systematically analyzed 1) for each individual lead, 2) at three different intervals after the J-point (J+40ms, J+60ms, J+80ms), and 3) at different time points during the test (baseline, maximal workload, 2min into recovery). Exercise-induced ischemia was detected in 481 (31%) patients. The diagnostic accuracy of ST-deviations was highest at +80ms after the J-point, and at 2min into recovery. At this point, ST-amplitude showed an AUC of 0.63 (95% CI 0.59-0.66) for the best-performing lead I. The combination of ST-amplitude and ST-slope in lead I did not increase the AUC. Lead I reached a sensitivity of 37% and a specificity of 83%, with similar sensitivity to manual ECG analysis (34%, p=0.31) but lower specificity (90%, p<0.001). When using ECG stress testing for evaluation of patients with suspected myocardial ischemia, the diagnostic accuracy of ST-deviations is highest when evaluated at +80ms after the J-point, and at 2min into recovery. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wendelin, Timothy J; Ho, Clifford K.; Horstman, Luke
This paper presents a study of alternative heliostat standby aiming strategies and their impact on avian flux hazards and operational performance of a concentrating solar power plant. A mathematical model was developed that predicts the bird-feather temperature as a function of solar irradiance, thermal emittance, convection, and thermal properties of the feather. The irradiance distribution in the airspace above the Ivanpah Unit 2 heliostat field was simulated using a ray-trace model for two different times of the day, four days of the year, and nine different standby aiming strategies. The impact of the alternative aiming strategies on operational performance wasmore » assessed by comparing the heliostat slew times from standby position to the receiver for the different aiming strategies. Increased slew times increased a proxy start-up time that reduced the simulated annual energy production. Results showed that spreading the radial aim points around the receiver to a distance of ~150 m or greater reduced the hazardous exposure times that the feather temperature exceeded the hazard metric of 160 degrees C. The hazardous exposure times were reduced by ~23% and 90% at a radial spread of aim points extending to 150 m and 250 m, respectively, but the simulated annual energy production decreased as a result of increased slew times. Single point-focus aiming strategies were also evaluated, but these strategies increased the exposure hazard relative to other aiming strategies.« less
Mueller, Silke C; Drewelow, Bernd
2013-05-01
The area under the concentration-time curve (AUC) after oral midazolam administration is commonly used for cytochrome P450 (CYP) 3A phenotyping studies. The aim of this investigation was to evaluate a limited sampling strategy for the prediction of AUC with oral midazolam. A total of 288 concentration-time profiles from 123 healthy volunteers who participated in four previously performed drug interaction studies with intense sampling after a single oral dose of 7.5 mg midazolam were available for evaluation. Of these, 45 profiles served for model building, which was performed by stepwise multiple linear regression, and the remaining 243 datasets served for validation. Mean prediction error (MPE), mean absolute error (MAE) and root mean squared error (RMSE) were calculated to determine bias and precision The one- to four-sampling point models with the best coefficient of correlation were the one-sampling point model (8 h; r (2) = 0.84), the two-sampling point model (0.5 and 8 h; r (2) = 0.93), the three-sampling point model (0.5, 2, and 8 h; r (2) = 0.96), and the four-sampling point model (0.5,1, 2, and 8 h; r (2) = 0.97). However, the one- and two-sampling point models were unable to predict the midazolam AUC due to unacceptable bias and precision. Only the four-sampling point model predicted the very low and very high midazolam AUC of the validation dataset with acceptable precision and bias. The four-sampling point model was also able to predict the geometric mean ratio of the treatment phase over the baseline (with 90 % confidence interval) results of three drug interaction studies in the categories of strong, moderate, and mild induction, as well as no interaction. A four-sampling point limited sampling strategy to predict the oral midazolam AUC for CYP3A phenotyping is proposed. The one-, two- and three-sampling point models were not able to predict midazolam AUC accurately.
Legibility Evaluation Using Point-of-regard Measurement
NASA Astrophysics Data System (ADS)
Saito, Daisuke; Saito, Keiichi; Saito, Masao
Web site visibility has become important because of the rapid dissemination of World Wide Web, and combinations of foreground and background colors are crucial in providing high visibility. In our previous studies, the visibilities of several web-safe color combinations were examined using a psychological method. In those studies, simple stimuli were used because of experimental restriction. In this paper, legibility of sentences on web sites was examined using a psychophisiological method, point-of-regard measurement, to obtain other practical data. Ten people with normal color sensations ranging from ages 21 to 29 were recruited. The number of characters per line in each page was arranged in the same number, and the four representative achromatic web-safe colors, that is, #000000, #666666, #999999 and #CCCCCC, were examined. The reading time per character and the gaze time per line were obtained from point-of-regard measurement, and the normalized with the reading time and the gaze time of the three colors were calculated and compared. As the results, it was shown that the time of reading and gaze become long at the same ratio when the contrast decreases by point-of-regard measurement. Therefore, it was indicated that the legibility of color combinations could be estimated by point-of-regard measurement.
Overview of timing/synchronization for digital communications
NASA Technical Reports Server (NTRS)
Stover, H. A.
1978-01-01
Systems in general, and switched systems in particular, are explained. It pointed out some of the criteria that greatly influence timing/synchronization subsystem design for a military communications network but have little or no significance for civil systems. Timing techniques were evaluated in terms of fundamental features. Different combinations of these features covered most possibilities from which a synchronous timing system could be chosen.
NASA Astrophysics Data System (ADS)
Purcell, E. K.; Seymour, J. P.; Yandamuri, S.; Kipke, D. R.
2009-08-01
In the published article, an error was made in figure 5. Specifically, the three-month, NSC-seeded image is a duplicate of the six-week image, and the one-day, probe alone image is a duplicate of the three-month image. The corrected figure is reproduced below. Figure 5 Figure 5. Glial encapsulation of each probe condition over the 3 month time course. Ox-42 labeled microglia and GFAP labeled astrocytes are shown. Images are taken from probes implanted in the same animal at each time point. NSC seeding was associated with reduced non-neuronal density at 1 day post-implantation in comparison to alginate coated probes and at the 1 week time point in comparison to untreated probes (P < 0.001). Glial activation is at its overall peak 1 week after insertion. A thin encapsulation layer surrounds probes at the 6 week and 3 month time points, with NSC-seeded probes having the greatest surrounding non-neuronal density P < 0.001). Interestingly, microglia appeared to have a ramified, or `surveilling', morphology surrounding a neural stem cell-alginate probe initially, whereas activated cells with an amoeboid structure were found near an alginate probe in the same hemisphere of one animal (left panels).
Ensemble Space-Time Correlation of Plasma Turbulence in the Solar Wind.
Matthaeus, W H; Weygand, J M; Dasso, S
2016-06-17
Single point measurement turbulence cannot distinguish variations in space and time. We employ an ensemble of one- and two-point measurements in the solar wind to estimate the space-time correlation function in the comoving plasma frame. The method is illustrated using near Earth spacecraft observations, employing ACE, Geotail, IMP-8, and Wind data sets. New results include an evaluation of both correlation time and correlation length from a single method, and a new assessment of the accuracy of the familiar frozen-in flow approximation. This novel view of the space-time structure of turbulence may prove essential in exploratory space missions such as Solar Probe Plus and Solar Orbiter for which the frozen-in flow hypothesis may not be a useful approximation.
Compatible Basal Area and Number of Trees Estimators from Remeasured Horizontal Point Samples
Francis A. Roesch; Edwin J. Green; Charles T. Scott
1989-01-01
Compatible groups of estimators for total value at time 1 (V1), survivor growth (S), and ingrowth (I) for use with permanent horizontal point samples are evaluated for the special cases of estimating the change in both the number of trees and basal area. Caveats which should be observed before any one compatible grouping of estimators is chosen...
Modeling hard clinical end-point data in economic analyses.
Kansal, Anuraag R; Zheng, Ying; Palencia, Roberto; Ruffolo, Antonio; Hass, Bastian; Sorensen, Sonja V
2013-11-01
The availability of hard clinical end-point data, such as that on cardiovascular (CV) events among patients with type 2 diabetes mellitus, is increasing, and as a result there is growing interest in using hard end-point data of this type in economic analyses. This study investigated published approaches for modeling hard end-points from clinical trials and evaluated their applicability in health economic models with different disease features. A review of cost-effectiveness models of interventions in clinically significant therapeutic areas (CV diseases, cancer, and chronic lower respiratory diseases) was conducted in PubMed and Embase using a defined search strategy. Only studies integrating hard end-point data from randomized clinical trials were considered. For each study included, clinical input characteristics and modeling approach were summarized and evaluated. A total of 33 articles (23 CV, eight cancer, two respiratory) were accepted for detailed analysis. Decision trees, Markov models, discrete event simulations, and hybrids were used. Event rates were incorporated either as constant rates, time-dependent risks, or risk equations based on patient characteristics. Risks dependent on time and/or patient characteristics were used where major event rates were >1%/year in models with fewer health states (<7). Models of infrequent events or with numerous health states generally preferred constant event rates. The detailed modeling information and terminology varied, sometimes requiring interpretation. Key considerations for cost-effectiveness models incorporating hard end-point data include the frequency and characteristics of the relevant clinical events and how the trial data is reported. When event risk is low, simplification of both the model structure and event rate modeling is recommended. When event risk is common, such as in high risk populations, more detailed modeling approaches, including individual simulations or explicitly time-dependent event rates, are more appropriate to accurately reflect the trial data.
Mohrs, Oliver K; Petersen, Steffen E; Voigtlaender, Thomas; Peters, Jutta; Nowak, Bernd; Heinemann, Markus K; Kauczor, Hans-Ulrich
2006-10-01
The aim of this study was to evaluate the diagnostic value of time-resolved contrast-enhanced MR angiography in adults with congenital heart disease. Twenty patients with congenital heart disease (mean age, 38 +/- 14 years; range, 16-73 years) underwent contrast-enhanced turbo fast low-angle shot MR angiography. Thirty consecutive coronal 3D slabs with a frame rate of 1-second duration were acquired. The mask defined as the first data set was subtracted from subsequent images. Image quality was evaluated using a 5-point scale (from 1, not assessable, to 5, excellent image quality). Twelve diagnostic parameters yielded 1 point each in case of correct diagnosis (binary analysis into normal or abnormal) and were summarized into three categories: anatomy of the main thoracic vessels (maximum, 5 points), sequential cardiac anatomy (maximum, 5 points), and shunt detection (maximum, 2 points). The results were compared with a combined clinical reference comprising medical or surgical reports and other imaging studies. Diagnostic accuracies were calculated for each of the parameters as well as for the three categories. The mean image quality was 3.7 +/- 1.0. Using a binary approach, 220 (92%) of the 240 single diagnostic parameters could be analyzed. The percentage of maximum diagnostic points, the sensitivity, the specificity, and the positive and the negative predictive values were all 100% for the anatomy of the main thoracic vessels; 97%, 87%, 100%, 100%, and 96% for sequential cardiac anatomy; and 93%, 93%, 92%, 88%, and 96% for shunt detection. Time-resolved contrast-enhanced MR angiography provides, in one breath-hold, anatomic and qualitative functional information in adult patients with congenital heart disease. The high diagnostic accuracy allows the investigator to tailor subsequent specific MR sequences within the same session.
García Vicente, A M; Soriano Castrejón, A; Cruz Mora, M Á; Ortega Ruiperez, C; Espinosa Aunión, R; León Martín, A; González Ageitos, A; Van Gómez López, O
2014-01-01
To assess dual time point 2-deoxy-2-[(18)F]fluoro-D-glucose (18)(F)FDG PET-CT accuracy in nodal staging and in detection of extra-axillary involvement. Dual time point [(18)F] FDG PET/CT scan was performed in 75 patients. Visual and semiquantitative assessment of lymph nodes was performed. Semiquantitative measurement of SUV and ROC-analysis were carried out to calculate SUV(max) cut-off value with the best diagnostic performance. Axillary and extra-axillary lymph node chains were evaluated. Sensitivity and specificity of visual assessment was 87.3% and 75%, respectively. SUV(max) values with the best sensitivity were 0.90 and 0.95 for early and delayed PET, respectively. SUV(max) values with the best specificity were 1.95 and 2.75, respectively. Extra-axillary lymph node involvement was detected in 26.7%. FDG PET/CT detected extra-axillary lymph node involvement in one-fourth of the patients. Semiquantitative lymph node analysis did not show any advantage over the visual evaluation. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.
A Novel Real-Time Reference Key Frame Scan Matching Method
Mohamed, Haytham; Moussa, Adel; Elhabiby, Mohamed; El-Sheimy, Naser; Sesay, Abu
2017-01-01
Unmanned aerial vehicles represent an effective technology for indoor search and rescue operations. Typically, most indoor missions’ environments would be unknown, unstructured, and/or dynamic. Navigation of UAVs in such environments is addressed by simultaneous localization and mapping approach using either local or global approaches. Both approaches suffer from accumulated errors and high processing time due to the iterative nature of the scan matching method. Moreover, point-to-point scan matching is prone to outlier association processes. This paper proposes a low-cost novel method for 2D real-time scan matching based on a reference key frame (RKF). RKF is a hybrid scan matching technique comprised of feature-to-feature and point-to-point approaches. This algorithm aims at mitigating errors accumulation using the key frame technique, which is inspired from video streaming broadcast process. The algorithm depends on the iterative closest point algorithm during the lack of linear features which is typically exhibited in unstructured environments. The algorithm switches back to the RKF once linear features are detected. To validate and evaluate the algorithm, the mapping performance and time consumption are compared with various algorithms in static and dynamic environments. The performance of the algorithm exhibits promising navigational, mapping results and very short computational time, that indicates the potential use of the new algorithm with real-time systems. PMID:28481285
Effect of Receiver Choosing on Point Positions Determination in Network RTK
NASA Astrophysics Data System (ADS)
Bulbul, Sercan; Inal, Cevat
2016-04-01
Nowadays, the developments in GNSS technique allow to determinate point positioning in real time. Initially, point positioning was determined by RTK (Real Time Kinematic) based on a reference station. But, to avoid systematic errors in this method, distance between the reference points and rover receiver must be shorter than10 km. To overcome this restriction in RTK method, the idea of setting more than one reference point had been suggested and, CORS (Continuously Operations Reference Systems) was put into practice. Today, countries like ABD, Germany, Japan etc. have set CORS network. CORS-TR network which has 146 reference points has also been established in 2009 in Turkey. In CORS-TR network, active CORS approach was adopted. In Turkey, CORS-TR reference stations covering whole country are interconnected and, the positions of these stations and atmospheric corrections are continuously calculated. In this study, in a selected point, RTK measurements based on CORS-TR, were made with different receivers (JAVAD TRIUMPH-1, TOPCON Hiper V, MAGELLAN PRoMark 500, PENTAX SMT888-3G, SATLAB SL-600) and with different correction techniques (VRS, FKP, MAC). In the measurements, epoch interval was taken as 5 seconds and measurement time as 1 hour. According to each receiver and each correction technique, means and differences between maximum and minimum values of measured coordinates, root mean squares in the directions of coordinate axis and 2D and 3D positioning precisions were calculated, the results were evaluated by statistical methods and the obtained graphics were interpreted. After evaluation of the measurements and calculations, for each receiver and each correction technique; the coordinate differences between maximum and minimum values were measured to be less than 8 cm, root mean squares in coordinate axis directions less than ±1.5 cm, 2D point positioning precisions less than ±1.5 cm and 3D point positioning precisions less than ±1.5 cm. In the measurement point, it has been concluded that VRS correction technique is generally better than other corrections techniques.
Hazewinkel, Herman A W; van den Brom, Walter E; Theyse, Lars F H; Pollmeier, Matthias; Hanson, Peter D
2008-02-01
A randomized, placebo-controlled, four-period cross-over laboratory study involving eight dogs was conducted to confirm the effective analgesic dose of firocoxib, a selective COX-2 inhibitor, in a synovitis model of arthritis. Firocoxib was compared to vedaprofen and carprofen, and the effect, defined as a change in weight bearing measured via peak ground reaction, was evaluated at treatment dose levels. A lameness score on a five point scale was also assigned to the affected limb. Peak vertical ground reaction force was considered to be the most relevant measurement in this study. The firocoxib treatment group performed significantly better than placebo at the 3 h post-treatment time point and significantly better than placebo and carprofen at the 7 h post-treatment time point. Improvement in lameness score was also significantly better in the dogs treated with firocoxib than placebo and carprofen at both the 3 and 7 h post-treatment time points.
Person detection and tracking with a 360° lidar system
NASA Astrophysics Data System (ADS)
Hammer, Marcus; Hebel, Marcus; Arens, Michael
2017-10-01
Today it is easily possible to generate dense point clouds of the sensor environment using 360° LiDAR (Light Detection and Ranging) sensors which are available since a number of years. The interpretation of these data is much more challenging. For the automated data evaluation the detection and classification of objects is a fundamental task. Especially in urban scenarios moving objects like persons or vehicles are of particular interest, for instance in automatic collision avoidance, for mobile sensor platforms or surveillance tasks. In literature there are several approaches for automated person detection in point clouds. While most techniques show acceptable results in object detection, the computation time is often crucial. The runtime can be problematic, especially due to the amount of data in the panoramic 360° point clouds. On the other hand, for most applications an object detection and classification in real time is needed. The paper presents a proposal for a fast, real-time capable algorithm for person detection, classification and tracking in panoramic point clouds.
Fixed-flexion view X-ray of the knee superior in detection and follow-up of knee osteoarthritis
Kan, Hiroyuki; Arai, Yuji; Kobayashi, Masashi; Nakagawa, Shuji; Inoue, Hiroaki; Hino, Manabu; Komaki, Shintaro; Ikoma, Kazuya; Ueshima, Keiichiro; Fujiwara, Hiroyoshi; Yokota, Isao; Kubo, Toshikazu
2017-01-01
Abstract A fixed flexion view (FFV) is useful for evaluating joint space when assessing the severity of osteoarthritis (OA) of the knee. We analyzed changes in joint space revealed by standing extended view (SEV) and FFV over a mean 4 years, to compare both views on their capacity to measure joint space width accurately at particular time points during follow-up. SEV and FFV images were acquired in patients with knee OA. The 81 patients (157 knees) followed up for ≥24 months were selected as study subjects. Medial joint space widths (MJSW), Kellgren–Lawrence (KL) grades, and reductions in MJSW on SEV (ΔSEV) and FFV (ΔFFV) were compared in knees evaluated by SEV and FFV. At both time-points, mean MJSW was significantly lower by FFV than by SEV. Mean MJSW was significantly lower at follow-up than at first examination by both SEV and FFV. At both time-points, the KL grade was higher by FFV than by SEV group. The ΔFFV was significantly greater than the ΔSEV. ΔSEV did not differ significantly among KL grades, but ΔFFV was significantly greater in patients with KL grade II than in patients with other KL grades. FFV is not only useful for evaluating joint space in knees with OA, but also for accurately evaluating the progression of OA. The risk of rapid progression of knee OA may be higher in patients with KL grade II, as determined by FFV. FFV may be superior to SEV in determining appropriate treatment strategies for knee OA. PMID:29245351
Approximation methods for combined thermal/structural design
NASA Technical Reports Server (NTRS)
Haftka, R. T.; Shore, C. P.
1979-01-01
Two approximation concepts for combined thermal/structural design are evaluated. The first concept is an approximate thermal analysis based on the first derivatives of structural temperatures with respect to design variables. Two commonly used first-order Taylor series expansions are examined. The direct and reciprocal expansions are special members of a general family of approximations, and for some conditions other members of that family of approximations are more accurate. Several examples are used to compare the accuracy of the different expansions. The second approximation concept is the use of critical time points for combined thermal and stress analyses of structures with transient loading conditions. Significant time savings are realized by identifying critical time points and performing the stress analysis for those points only. The design of an insulated panel which is exposed to transient heating conditions is discussed.
Stiletto, R; Röthke, M; Schäfer, E; Lefering, R; Waydhas, Ch
2006-10-01
Patient security has become one of the major aspects of clinical management in recent years. The crucial point in research was focused on malpractice. In contradiction to the economic process in non medical fields, the analysis of errors during the in-patient treatment time was neglected. Patient risk management can be defined as a structured procedure in a clinical unit with the aim to reduce harmful events. A risk point model was created based on a Delphi process and founded on the DIVI data register. The risk point model was evaluated in clinically working ICU departments participating in the register data base. The results of the risk point evaluation will be integrated in the next data base update. This might be a step to improve the reliability of the register to measure quality assessment in the ICU.
Cole, Lynette K; Luu, Dao H; Rajala-Schultz, Paivi J; Meadows, Cheyney; Torres, Audrey H
2007-04-01
The purpose of this study was to evaluate the in vitro activity of an ear rinse containing tromethamine, EDTA, benzyl alcohol and 0.1% ketoconazole in purified water on Malassezia organisms from dogs with otitis externa. Malassezia organisms were collected from ear swab samples from the external ear canal of 19 dogs with otitis externa plus one control strain of Malassezia pachydermatis. Three test solutions were evaluated: ER (EDTA, tromethamine, benzyl alcohol), ER + keto (EDTA, tromethamine, benzyl alcohol, ketoconazole), and H2O (purified water). Ten-millilitre aliquots of each test solution was transferred into 20 tubes and inoculated with one of the isolates (1 tube per isolate: 19 clinical and 1 control strain). Samples were retrieved from each tube at five time points (0, 15, 30, 45 and 60 min), transferred to Petri dishes, mixed with Sabouraud dextrose agar supplemented with 0.5% Tween 80 and incubated. Following incubation, the plates were examined for growth and colonies counted as colony-forming units per millilitre. The data were analysed using a repeated measures analysis, with pair-wise comparisons of solution-time combinations. There was a significant reduction in Malassezia growth in ER + keto at all time points (P < 0.0001) compared to time zero. Neither ER nor H2O had any effect on the growth of Malassezia. ER + keto was significantly more effective in reducing Malassezia growth (P < 0.0001) at all time points compared to both ER and H2O. ER + keto may be useful in the treatment of Malassezia otitis externa. Future studies should be performed to evaluate the in vivo efficacy of ER + keto as treatment for otic infections caused by Malassezia.
Chhabra, Anmol; Quinn, Andrea; Ries, Amanda
2018-01-01
Accurate history collection is integral to medication reconciliation. Studies support pharmacy involvement in the process, but assessment of global time spent is limited. The authors hypothesized the location of a medication-focused interview would impact time spent. The objective was to compare time spent by pharmacists and nurses based on the location of a medication-focused interview. Time spent by the interviewing pharmacist, admitting nurse, and centralized pharmacist verifying admission orders was collected. Patient groups were based on whether the interview was conducted in the emergency department (ED) or medical floor. The primary end point was a composite of the 3 time points. Secondary end points were individual time components and number and types of transcription discrepancies identified during medical floor interviews. Pharmacists and nurses spent an average of ten fewer minutes per ED patient versus a medical floor patient ( P = .028). Secondary end points were not statistically significant. Transcription discrepancies were identified at a rate of 1 in 4 medications. Post hoc analysis revealed the time spent by pharmacists and nurses was 2.4 minutes shorter per medication when interviewed in the ED ( P < .001). The primary outcome was statistically and clinically significant. Limitations included inability to blind and lack of cost-saving analysis. Pharmacist involvement in ED medication reconciliation leads to time savings during the admission process.
Enhancing Early Childhood Mental Health Primary Care Services: Evaluation of MA Project LAUNCH.
Molnar, Beth E; Lees, Kristin E; Roper, Kate; Byars, Natasha; Méndez-Peñate, Larisa; Moulin, Christy; McMullen, William; Wolfe, Jessica; Allen, Deborah
2018-06-16
Objectives The purpose of this study was to evaluate the efficacy of an innovative early childhood mental health intervention, Massachusetts Project LAUNCH. Early childhood mental health clinicians and family partners (paraprofessionals with lived experience) were embedded within community pediatric medical homes. Methods A longitudinal study design was used to test the hypotheses that (1) children who received services would experience decreased social, emotional and behavioral problems over time and (2) caregivers' stress and depressive symptoms would decrease over time. Families who were enrolled in services and who consented to participate in the evaluation study were included in analyses (N = 225). Individual growth models were used to test longitudinal effects among MA LAUNCH participants (children and caregivers) over three time points using screening tools. Results Analyses showed that LAUNCH children who scored in age-specific clinically significant ranges of social, emotional and behavioral problems at Time 1 scored in the normal range on average by Time 3. Caregivers' stress and depressive symptoms also declined across the three time points. Results support hypotheses that the LAUNCH intervention improved social and emotional health for children and caregivers. Conclusions for Practice This study led to sustainability efforts, an expansion of the model to three additional communities across the state and development of an online toolkit for other communities interested in implementation.
Applications of Generalized Derivatives to Viscoelasticity.
1979-11-01
Integration Used to Evaluate the Inverse Transform 78 B-i Schematic of the Half-Space of Newtonian Fluid Bounded by a "Wetted" Surface 96 C-I The...of the response at discrete frequencies. The inverse transform of the response is evaluated numerically to produce the time history. The major drawback...of this method is the arduous task of calculating the inverse transform for every point in time at which the value of the response is required. The
Gupta, Ekta; Agarwala, Pragya; Kumar, Guresh; Maiwall, Rakhi; Sarin, Shiv Kumar
2017-03-01
Molecular testing at the point-of-care may turn out to be game changer for HCV diagnosis and treatment monitoring, through increased sensitivity, reduced turnaround time, and ease of performance. One such assay GeneXpert ® has recently been released. Comparative analysis between performances of GeneXpert ® and Abbott HCV-RNA was done. 174 HCV infected patients were recruited and, one time plasma samples from 154 patients and repeated samples from 20 patients, obtained at specific treatment time-points (0, 4, 12 and 24) weeks were serially re-tested on Xpert ® . Genotype 3 was the commonest, seen in 80 (66%) of the cases, genotype 1 in 34 (28.3%), genotype 4 in 4 (3.3%) and genotypes 2 and 5 in 1 (0.8%) each. Median HCV RNA load was 4.69 log 10 (range: 0-6.98log 10 ) IU/ml. Overall a very good correlation was seen between the two assays (R 2 =0.985), concordance of the results between the assays was seen in 138 samples (89.6%). High and low positive standards were tested ten times on Xpert ® to evaluate the precision and the coefficient of variation was 0.01 for HPC and 0.07 for the LPC. Monitoring of patients on two different regimes of treatment, pegylated interferon plus ribavirin and sofosbuvir plus ribavirin was done by both the systems at baseline, 4, 12 and 24 weeks. Perfect correlation between the assays in the course of therapy at different treatment time- point in genotypes 3 and 1 was seen. The study demonstrates excellent performance of the Xpert ® HCV assay in viral load assessment and in treatment course monitoring consistency. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Arkin, C. Richard; Ottens, Andrew K.; Diaz, Jorge A.; Griffin, Timothy P.; Follestein, Duke; Adams, Fredrick; Steinrock, T. (Technical Monitor)
2001-01-01
For Space Shuttle launch safety, there is a need to monitor the concentration of H2, He, O2 and Ar around the launch vehicle. Currently a large mass spectrometry system performs this task, using long transport lines to draw in samples. There is great interest in replacing this stationary system with several miniature, portable, rugged mass spectrometers which act as point sensors which can be placed at the sampling point. Five commercial and two non-commercial analyzers are evaluated. The five commercial systems include the Leybold Inficon XPR-2 linear quadrupole, the Stanford Research (SRS-100) linear quadrupole, the Ferran linear quadrupole array, the ThermoQuest Polaris-Q quadrupole ion trap, and the IonWerks Time-of-Flight (TOF). The non-commercial systems include a compact double focusing sector (CDFMS) developed at the University of Minnesota, and a quadrupole ion trap (UF-IT) developed at the University of Florida. The System Volume is determined by measuring the entire system volume including the mass analyzer, its associated electronics, the associated vacuum system, the high vacuum pump and rough pump. Also measured are any ion gauge controllers or other required equipment. Computers are not included. Scan Time is the time required for one scan to be acquired and the data to be transferred. It is determined by measuring the time required acquiring a known number of scans and dividing by said number of scans. Limit of Detection is determined first by performing a zero-span calibration (using a 10-point data set). Then the limit of detection (LOD) is defined as 3 times the standard deviation of the zero data set. (An LOD of 10 ppm or less is considered acceptable.)
NASA Technical Reports Server (NTRS)
Boulanger, Richard P., Jr.; Kwauk, Xian-Min; Stagnaro, Mike; Kliss, Mark (Technical Monitor)
1998-01-01
The BIO-Plex control system requires real-time, flexible, and reliable data delivery. There is no simple "off-the-shelf 'solution. However, several commercial packages will be evaluated using a testbed at ARC for publish- and-subscribe and client-server communication architectures. Point-to-point communication architecture is not suitable for real-time BIO-Plex control system. Client-server architecture provides more flexible data delivery. However, it does not provide direct communication among nodes on the network. Publish-and-subscribe implementation allows direct information exchange among nodes on the net, providing the best time-critical communication. In this work Network Data Delivery Service (NDDS) from Real-Time Innovations, Inc. ARTIE will be used to implement publish-and subscribe architecture. It offers update guarantees and deadlines for real-time data delivery. Bridgestone, a data acquisition and control software package from National Instruments, will be tested for client-server arrangement. A microwave incinerator located at ARC will be instrumented with a fieldbus network of control devices. BridgeVIEW will be used to implement an enterprise server. An enterprise network consisting of several nodes at ARC and a WAN connecting ARC and RISC will then be setup to evaluate proposed control system architectures. Several network configurations will be evaluated for fault tolerance, quality of service, reliability and efficiency. Data acquired from these network evaluation tests will then be used to determine preliminary design criteria for the BIO-Plex distributed control system.
THE AUTO-CRITIQUE METHOD OF INSTRUCTIONAL EVALUATION.
ERIC Educational Resources Information Center
ANDERSON, JOHN E.
OF 26 FULL-TIME MEMBERS AT COLUMBUS COLLEGE, 19 VOLUNTARILY PARTICIPATED IN A STUDY OF A SELF-EVALUATION PROCEDURE. USING A 7-POINT SCALE, EACH PARTICIPANT RATED HIMSELF ON (1) SPEAKING VOICE, (2) MANNERISMS, (3) KNOWLEDGE OF SUBJECT, (4) HIS ENTHUSIASM, (5) CLASS ENTHUSIASM, (6) DIGRESSIONS, (7) ORGANIZATION AND PREPARATION, (8) USE OF ANALOGIES,…
Bagis, Bora; Baltacioglu, Esra; Özcan, Mutlu; Ustaomer, Seda
2011-03-01
To investigate the persistence of staining after the use of chlorhexidine gluconate mouthrinse. Twenty-four subjects (nine women and 15 men) who underwent periodontal therapy and were prescribed the use of 0.2% chlorhexidine gluconate mouthrinse participated in this study. Color values of maxillary central incisors, canines, and first molars were recorded at baseline; 3 days; and 1, 2, and 3 weeks of twice-daily chlorhexidine gluconate use with a digital intraoral colorimeter according to the CIE L*a*b* coordinates. While color-change (Delta E) values showed significant differences (P=.020) at different time points (10.1, 8.9, 8.9, 9.4, after 3 days and 1, 2, and 3 weeks, respectively), the duration of chlorhexidine gluconate use did not significantly affect the results (P=.873) (two-way ANOVA, Tukey test). No significant difference was found among Delta L* (P=.070), Delta a* (P=.169), and Delta b* (P=.691) values at any time point (one-way ANOVA). Measurements of baseline to day 3 differences showed significantly higher Delta E values than those at other time points (P<.05), but this change remained nonsignificant after 1, 2, and 3 weeks of chlorhexidine gluconate use (P>.05) (Tukey test). The highest visible staining occurred on the first molars at all time points (83%, 79%, 79%, and 96% after 3 days and 1, 2, and 3 weeks, respectively) compared to the other teeth evaluated. The staining effect of chlorhexidine gluconate mouthrinse on natural dentition should be expected to be the highest in the first few days of use.
Optimized Dose Distribution of Gammamed Plus Vaginal Cylinders
DOE Office of Scientific and Technical Information (OSTI.GOV)
Supe, Sanjay S.; Bijina, T.K.; Varatharaj, C.
2009-04-01
Endometrial carcinoma is the most common malignancy arising in the female genital tract. Intracavitary vaginal cuff irradiation may be given alone or with external beam irradiation in patients determined to be at risk for locoregional recurrence. Vaginal cylinders are often used to deliver a brachytherapy dose to the vaginal apex and upper vagina or the entire vaginal surface in the management of postoperative endometrial cancer or cervical cancer. The dose distributions of HDR vaginal cylinders must be evaluated carefully, so that clinical experiences with LDR techniques can be used in guiding optimal use of HDR techniques. The aim of thismore » study was to optimize dose distribution for Gammamed plus vaginal cylinders. Placement of dose optimization points was evaluated for its effect on optimized dose distributions. Two different dose optimization point models were used in this study, namely non-apex (dose optimization points only on periphery of cylinder) and apex (dose optimization points on periphery and along the curvature including the apex points). Thirteen dwell positions were used for the HDR dosimetry to obtain a 6-cm active length. Thus 13 optimization points were available at the periphery of the cylinder. The coordinates of the points along the curvature depended on the cylinder diameters and were chosen for each cylinder so that four points were distributed evenly in the curvature portion of the cylinder. Diameter of vaginal cylinders varied from 2.0 to 4.0 cm. Iterative optimization routine was utilized for all optimizations. The effects of various optimization routines (iterative, geometric, equal times) was studied for the 3.0-cm diameter vaginal cylinder. The effect of source travel step size on the optimized dose distributions for vaginal cylinders was also evaluated. All optimizations in this study were carried for dose of 6 Gy at dose optimization points. For both non-apex and apex models of vaginal cylinders, doses for apex point and three dome points were higher for the apex model compared with the non-apex model. Mean doses to the optimization points for both the cylinder models and all the cylinder diameters were 6 Gy, matching with the prescription dose of 6 Gy. Iterative optimization routine resulted in the highest dose to apex point and dome points. The mean dose for optimization point was 6.01 Gy for iterative optimization and was much higher than 5.74 Gy for geometric and equal times routines. Step size of 1 cm gave the highest dose to the apex point. This step size was superior in terms of mean dose to optimization points. Selection of dose optimization points for the derivation of optimized dose distributions for vaginal cylinders affects the dose distributions.« less
Sedentary Behaviour Profiling of Office Workers: A Sensitivity Analysis of Sedentary Cut-Points
Boerema, Simone T.; Essink, Gerard B.; Tönis, Thijs M.; van Velsen, Lex; Hermens, Hermie J.
2015-01-01
Measuring sedentary behaviour and physical activity with wearable sensors provides detailed information on activity patterns and can serve health interventions. At the basis of activity analysis stands the ability to distinguish sedentary from active time. As there is no consensus regarding the optimal cut-point for classifying sedentary behaviour, we studied the consequences of using different cut-points for this type of analysis. We conducted a battery of sitting and walking activities with 14 office workers, wearing the Promove 3D activity sensor to determine the optimal cut-point (in counts per minute (m·s−2)) for classifying sedentary behaviour. Then, 27 office workers wore the sensor for five days. We evaluated the sensitivity of five sedentary pattern measures for various sedentary cut-points and found an optimal cut-point for sedentary behaviour of 1660 × 10−3 m·s−2. Total sedentary time was not sensitive to cut-point changes within ±10% of this optimal cut-point; other sedentary pattern measures were not sensitive to changes within the ±20% interval. The results from studies analyzing sedentary patterns, using different cut-points, can be compared within these boundaries. Furthermore, commercial, hip-worn activity trackers can implement feedback and interventions on sedentary behaviour patterns, using these cut-points. PMID:26712758
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goyal, M; Shobhit University, Meerut, Uttar Pradesh; Manjhi, J
Purpose: This study evaluated dosimetric parameters for actual treatment plans versus decay corrected treatment plans for cervical HDR brachytherapy. Methods: 125 plans of 25 patients, who received 5 fractions of HDR brachytherapy, were evaluated in this study. Dose was prescribed to point A (ICRU-38) and High risk clinical tumor volume (HR-CTV) and organs at risk (OAR) were, retrospectively, delineated on original CT images by treating physician. First HDR plan was considered as reference plan and decay correction was applied to calculate treatment time for subsequent fractions, and was applied, retrospectively, to determine point A, HR-CTV D90, and rectum and bladdermore » doses. Results: The differences between mean point A reference doses and the point A doses of the plans computed using decay times were found to be 1.05%±0.74% (−2.26% to 3.26%) for second fraction; −0.25%±0.84% (−3.03% to 3.29%) for third fraction; 0.04%±0.70% (−2.68% to 2.56%) for fourth fraction and 0.30%±0.81% (−3.93% to 2.67%) for fifth fraction. Overall mean point A dose difference, for all fractions, was 0.29%±0.38% (within ± 5%). Mean rectum and bladder dose differences were calculated to be −3.46%±0.12% and −2.47%±0.09%, for points, respectively, and −1.72%±0.09% and −0.96%±0.06%, for D2cc, respectively. HR-CTV D90 mean dose difference was found to be −1.67% ± 0.11%. There was no statistically significant difference between the reference planned point A doses and that calculated using decay time to the subsequent fractions (p<0.05). Conclusion: This study reveals that a decay corrected treatment will provide comparable dosimetric results and can be utilized for subsequent fractions of cervical HDR brachytherapy instead of actual treatment planning. This approach will increase efficiency, decrease workload, reduce patient observation time between applicator insertion and treatment delivery. This would be particularly useful for institutions with limited resources or large patient populations with limited access to care.« less
Alignment of time-resolved data from high throughput experiments.
Abidi, Nada; Franke, Raimo; Findeisen, Peter; Klawonn, Frank
2016-12-01
To better understand the dynamics of the underlying processes in cells, it is necessary to take measurements over a time course. Modern high-throughput technologies are often used for this purpose to measure the behavior of cell products like metabolites, peptides, proteins, [Formula: see text]RNA or mRNA at different points in time. Compared to classical time series, the number of time points is usually very limited and the measurements are taken at irregular time intervals. The main reasons for this are the costs of the experiments and the fact that the dynamic behavior usually shows a strong reaction and fast changes shortly after a stimulus and then slowly converges to a certain stable state. Another reason might simply be missing values. It is common to repeat the experiments and to have replicates in order to carry out a more reliable analysis. The ideal assumptions that the initial stimulus really started exactly at the same time for all replicates and that the replicates are perfectly synchronized are seldom satisfied. Therefore, there is a need to first adjust or align the time-resolved data before further analysis is carried out. Dynamic time warping (DTW) is considered as one of the common alignment techniques for time series data with equidistant time points. In this paper, we modified the DTW algorithm so that it can align sequences with measurements at different, non-equidistant time points with large gaps in between. This type of data is usually known as time-resolved data characterized by irregular time intervals between measurements as well as non-identical time points for different replicates. This new algorithm can be easily used to align time-resolved data from high-throughput experiments and to come across existing problems such as time scarcity and existing noise in the measurements. We propose a modified method of DTW to adapt requirements imposed by time-resolved data by use of monotone cubic interpolation splines. Our presented approach provides a nonlinear alignment of two sequences that neither need to have equi-distant time points nor measurements at identical time points. The proposed method is evaluated with artificial as well as real data. The software is available as an R package tra (Time-Resolved data Alignment) which is freely available at: http://public.ostfalia.de/klawonn/tra.zip .
Effect of hand paddles and parachute on butterfly coordination.
Telles, Thiago; Barroso, Renato; Barbosa, Augusto Carvalho; Salgueiro, Diego Fortes de Souza; Colantonio, Emilson; Andries Júnior, Orival
2015-01-01
This study investigated the effects of hand paddles, parachute and hand paddles plus parachute on the inter-limb coordination of butterfly swimming. Thirteen male swimmers were evaluated in four random maximal intensity conditions: without equipment, with hand paddles, with parachute and with hand paddles + parachute. Arm and leg stroke phases were identified by 2D video analysis to calculate the total time gap (T1: time between hands' entry in the water and high break-even point of the first undulation; T2: time between the beginning of the hand's backward movement and low break-even point of the first undulation; T3: time between the hand's arrival in a vertical plane to the shoulders and high break-even point of the second undulation; T4: time between the hand's release from the water and low break-even point of the second undulation). The swimming velocity was reduced and T1, T2 and T3 increased in parachute and hand paddles + parachute. No changes were observed in T4. Total time gap decreased in parachute and hand paddles + parachute. It is concluded that hand paddles do not influence the arm-to-leg coordination in butterfly, while parachute and hand paddles + parachute do change it, providing a greater propulsive continuity.
Burnstein, Bryan D; Steele, Russell J; Shrier, Ian
2011-01-01
Fitness testing is used frequently in many areas of physical activity, but the reliability of these measurements under real-world, practical conditions is unknown. To evaluate the reliability of specific fitness tests using the methods and time periods used in the context of real-world sport and occupational management. Cohort study. Eighteen different Cirque du Soleil shows. Cirque du Soleil physical performers who completed 4 consecutive tests (6-month intervals) and were free of injury or illness at each session (n = 238 of 701 physical performers). Performers completed 6 fitness tests on each assessment date: dynamic balance, Harvard step test, handgrip, vertical jump, pull-ups, and 60-second jump test. We calculated the intraclass coefficient (ICC) and limits of agreement between baseline and each time point and the ICC over all 4 time points combined. Reliability was acceptable (ICC > 0.6) over an 18-month time period for all pairwise comparisons and all time points together for the handgrip, vertical jump, and pull-up assessments. The Harvard step test and 60-second jump test had poor reliability (ICC < 0.6) between baseline and other time points. When we excluded the baseline data and calculated the ICC for 6-month, 12-month, and 18-month time points, both the Harvard step test and 60-second jump test demonstrated acceptable reliability. Dynamic balance was unreliable in all contexts. Limit-of-agreement analysis demonstrated considerable intraindividual variability for some tests and a learning effect by administrators on others. Five of the 6 tests in this battery had acceptable reliability over an 18-month time frame, but the values for certain individuals may vary considerably from time to time for some tests. Specific tests may require a learning period for administrators.
Time-domain NMR study of the drying of hemicellulose extracted aspen (Populus tremuloides Michx.)
Thomas Elder; Carl Houtman
2013-01-01
The effect of hot water on aspen chips has been evaluated using time-domain low-field nuclear magnetic resonance (NMR) spectroscopy. At moisture contents above fiber saturation point, treated chips exhibit relaxation times of free water longer than for the control. This is consistent with the removal of hemicelluloses given the hydrophilicity of these polysaccharides....
Guan, Zheng; Zhang, Guan-min; Ma, Ping; Liu, Li-hong; Zhou, Tian-yan; Lu, Wei
2010-07-01
In this study, we evaluated the influence of different variance from each of the parameters on the output of tacrolimus population pharmacokinetic (PopPK) model in Chinese healthy volunteers, using Fourier amplitude sensitivity test (FAST). Besides, we estimated the index of sensitivity within whole course of blood sampling, designed different sampling times, and evaluated the quality of parameters' and the efficiency of prediction. It was observed that besides CL1/F, the index of sensitivity for all of the other four parameters (V1/F, V2/F, CL2/F and k(a)) in tacrolimus PopPK model showed relatively high level and changed fast with the time passing. With the increase of the variance of k(a), its indices of sensitivity increased obviously, associated with significant decrease in sensitivity index for the other parameters, and obvious change in peak time as well. According to the simulation of NONMEM and the comparison among different fitting results, we found that the sampling time points designed according to FAST surpassed the other time points. It suggests that FAST can access the sensitivities of model parameters effectively, and assist the design of clinical sampling times and the construction of PopPK model.
Jerosch-Herold, Christina
2003-06-01
A longitudinal dynamic cohort study was conducted on patients with median nerve injuries to evaluate the relative responsiveness of five sensibility tests: touch threshold using the WEST (monofilaments), static two-point discrimination, locognosia, a pick-up test and an object recognition test. Repeated assessments were performed starting at 6 months after surgery. In order to compare the relative responsiveness of each test, effect size and the standard response mean were calculated for sensibility changes occurring between 6 and 18 months after repair. Large effect sizes (>0.8) and standard response means (>0.8) were obtained for the WEST, locognosia, pick-up and object recognition tests. Two-point discrimination was hardly measurable at any time point and exhibited strong flooring effects. Further analysis of all time points was undertaken to assess the strength of the monotonic relationship between test scores and time elapsed since surgery. Comparison of monotonicity between the five tests indicated that the WEST performed best, whereas two-point discrimination performed worst. These results suggest that the monofilament test (WEST), locognosia test, Moberg pick-up test and tactile gnosis test capture sensibility changes over time well and should be considered for inclusion in the outcome assessment of patients with median nerve injury.
Evaluation of the leap motion controller as a new contact-free pointing device.
Bachmann, Daniel; Weichert, Frank; Rinkenauer, Gerhard
2014-12-24
This paper presents a Fitts' law-based analysis of the user's performance in selection tasks with the Leap Motion Controller compared with a standard mouse device. The Leap Motion Controller (LMC) is a new contact-free input system for gesture-based human-computer interaction with declared sub-millimeter accuracy. Up to this point, there has hardly been any systematic evaluation of this new system available. With an error rate of 7.8% for the LMC and 2.8% for the mouse device, movement times twice as large as for a mouse device and high overall effort ratings, the Leap Motion Controller's performance as an input device for everyday generic computer pointing tasks is rather limited, at least with regard to the selection recognition provided by the LMC.
Evaluation of the Leap Motion Controller as a New Contact-Free Pointing Device
Bachmann, Daniel; Weichert, Frank; Rinkenauer, Gerhard
2015-01-01
This paper presents a Fitts' law-based analysis of the user's performance in selection tasks with the Leap Motion Controller compared with a standard mouse device. The Leap Motion Controller (LMC) is a new contact-free input system for gesture-based human-computer interaction with declared sub-millimeter accuracy. Up to this point, there has hardly been any systematic evaluation of this new system available. With an error rate of 7.8 % for the LMC and 2.8% for the mouse device, movement times twice as large as for a mouse device and high overall effort ratings, the Leap Motion Controller's performance as an input device for everyday generic computer pointing tasks is rather limited, at least with regard to the selection recognition provided by the LMC. PMID:25609043
NASA Technical Reports Server (NTRS)
Walden, T.
1978-01-01
The clinical performance of the Lixiscope in orthopedics was compared with routine radiography. Portability and size were the major advantages of the Lixiscope. The main disadvantage at this point in time was the Lixiscope's inability to study large areas.
Pulse-Echo Ultrasonic Imaging Method for Eliminating Sample Thickness Variation Effects
NASA Technical Reports Server (NTRS)
Roth, Don J. (Inventor)
1997-01-01
A pulse-echo, immersion method for ultrasonic evaluation of a material which accounts for and eliminates nonlevelness in the equipment set-up and sample thickness variation effects employs a single transducer and automatic scanning and digital imaging to obtain an image of a property of the material, such as pore fraction. The nonlevelness and thickness variation effects are accounted for by pre-scan adjustments of the time window to insure that the echoes received at each scan point are gated in the center of the window. This information is input into the scan file so that, during the automatic scanning for the material evaluation, each received echo is centered in its time window. A cross-correlation function calculates the velocity at each scan point, which is then proportionalized to a color or grey scale and displayed on a video screen.
Igl, W; Zwingmann, C; Faller, H
2005-04-01
In rehabilitation research patient questionnaires are widely used for evaluative purposes, i. e. to measure improvements or deteriorations over time. This is only possible if the questionnaires applied appropriately reflect "true" change over time, i. e. they have to be sensitive to change. The aim of this paper is to point out the importance of the "sensitivity to change" concept for evaluative assessment tools and evaluative studies, respectively, considering quality of life research as an example. Various qualitative aspects, e. g. scaling of response options of assessment tools, are covered as well as quantitative methods, i. e. study designs and indices. Furthermore, recommendations for interpretation are given.
An effective CPR home learning system. A program evaluation.
Starr, L M
1998-06-01
1. Program evaluation using a self instruction CPR home learning system indicated that people could learn CPR without attending a formal class. Reported training time for adult CPR averaged 1 hour, and ease of understanding was rated 4.9 on a 5 point scale. 2. Use of a home learning system can benefit a workplace by reducing reliance on a CPR instructor, reducing total training time, and exposing families and others in the community to the learning experience. 3. This program evaluation suggests that this training methodology supports the mission of AHA, and also can meet corporate objectives.
Experimental design and efficient parameter estimation in preclinical pharmacokinetic studies.
Ette, E I; Howie, C A; Kelman, A W; Whiting, B
1995-05-01
Monte Carlo simulation technique used to evaluate the effect of the arrangement of concentrations on the efficiency of estimation of population pharmacokinetic parameters in the preclinical setting is described. Although the simulations were restricted to the one compartment model with intravenous bolus input, they provide the basis of discussing some structural aspects involved in designing a destructive ("quantic") preclinical population pharmacokinetic study with a fixed sample size as is usually the case in such studies. The efficiency of parameter estimation obtained with sampling strategies based on the three and four time point designs were evaluated in terms of the percent prediction error, design number, individual and joint confidence intervals coverage for parameter estimates approaches, and correlation analysis. The data sets contained random terms for both inter- and residual intra-animal variability. The results showed that the typical population parameter estimates for clearance and volume were efficiently (accurately and precisely) estimated for both designs, while interanimal variability (the only random effect parameter that could be estimated) was inefficiently (inaccurately and imprecisely) estimated with most sampling schedules of the two designs. The exact location of the third and fourth time point for the three and four time point designs, respectively, was not critical to the efficiency of overall estimation of all population parameters of the model. However, some individual population pharmacokinetic parameters were sensitive to the location of these times.
Kandala, Sridhar; Nolan, Dan; Laumann, Timothy O.; Power, Jonathan D.; Adeyemo, Babatunde; Harms, Michael P.; Petersen, Steven E.; Barch, Deanna M.
2016-01-01
Abstract Like all resting-state functional connectivity data, the data from the Human Connectome Project (HCP) are adversely affected by structured noise artifacts arising from head motion and physiological processes. Functional connectivity estimates (Pearson's correlation coefficients) were inflated for high-motion time points and for high-motion participants. This inflation occurred across the brain, suggesting the presence of globally distributed artifacts. The degree of inflation was further increased for connections between nearby regions compared with distant regions, suggesting the presence of distance-dependent spatially specific artifacts. We evaluated several denoising methods: censoring high-motion time points, motion regression, the FMRIB independent component analysis-based X-noiseifier (FIX), and mean grayordinate time series regression (MGTR; as a proxy for global signal regression). The results suggest that FIX denoising reduced both types of artifacts, but left substantial global artifacts behind. MGTR significantly reduced global artifacts, but left substantial spatially specific artifacts behind. Censoring high-motion time points resulted in a small reduction of distance-dependent and global artifacts, eliminating neither type. All denoising strategies left differences between high- and low-motion participants, but only MGTR substantially reduced those differences. Ultimately, functional connectivity estimates from HCP data showed spatially specific and globally distributed artifacts, and the most effective approach to address both types of motion-correlated artifacts was a combination of FIX and MGTR. PMID:27571276
Ray, Samiran; Cvetkovic, Mirjana; Brierley, Joe; Lutman, Daniel H; Pathan, Nazima; Ramnarayan, Padmanabhan; Inwald, David P; Peters, Mark J
2016-09-01
Shock index (SI) (heart rate [HR]/systolic blood pressure [SBP]) has been used to predict outcome in both adult and pediatric sepsis within the intensive care unit (ICU). We aimed to evaluate the utility of SI before pediatric ICU (PICU) admission. We conducted a retrospective observational study of children referred to a pediatric intensive care transport service (PICTS) between 2005 and 2011. The predictive value of SI, HR, and blood pressure at three prespecified time points (at referral to PICTS, at PICTS arrival at the referring hospital, and at PICU admission) and changes in SI between the time points were evaluated. Death within the first 48 h of ICU admission (early death) was the primary outcome variable. Over the 7-year period, 633 children with sepsis were referred to the PICTS. Thirty-nine children died before transport to a PICU, whereas 474 were transported alive. Adjusting for age, time points, and time duration in a multilevel regression analysis, SI was significantly higher in those who died early. There was a significant improvement in SI with the transport team in survivors but not in nonsurvivors. However, the predictive value of a change in SI for mortality was no better than either a change in HR or blood pressure. The absolute or change in SI does not predict early death any more than HR and SBP individually in children with sepsis.
Chondral defect repair after the microfracture procedure: a nonhuman primate model.
Gill, Thomas J; McCulloch, Patrick C; Glasson, Sonya S; Blanchet, Tracey; Morris, Elizabeth A
2005-05-01
The extent and time course of chondral defect healing after microfracture in humans are not well described. Although most physicians recommend a period of activity and weightbearing restriction to protect the healing cartilage, there are limited data on which to base decisions regarding the duration of such restrictions. Evaluation of the status of chondral defect repair at different time points after microfracture in a primate model may provide a rationale for postoperative activity recommendations. Descriptive laboratory study. Full-thickness chondral defects created on the femoral condyles and trochlea of 12 cynomolgus macaques were treated with microfracture and evaluated by gross and histologic examination at 6 and 12 weeks. At 6 weeks, there was limited chondral repair and ongoing resorption of subchondral bone. By 12 weeks, the defects were completely filled and showed more mature cartilage and bone repair. In the primate animal model, significant improvements in the extent and quality of cartilage repair were observed from the 6- to 12-week time points after microfracture. The poor status of the defect repair at 6 weeks and the ongoing healing observed from the 6- to 12-week time points may indicate that the repair is vulnerable during this initial postoperative period. Assuming the goal of postoperative weightbearing and activity restriction in patients after microfracture is to protect immature repair tissue, this study lends support to extending such recommendations longer than 6 weeks.
Xuesong, Du; Wei, Xue; Heng, Liu; Xiao, Chen; Shunan, Wang; Yu, Guo; Weiguo, Zhang
2017-09-01
Background Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has been proved useful in evaluating glioma angiogenesis, but the utility in evaluating neovascularization patterns has not been reported. Purpose To evaluate in vivo real-time glioma neovascularization patterns by measuring glioma perfusion quantitatively using DCE-MRI. Material and Methods Thirty Sprague-Dawley rats were used to establish C6 orthotopic glioma model and underwent MRI and pathology detections. As MRI and pathology were performed at six time points (i.e. 4, 8, 12, 16, 20, and 24 days) post transplantation, neovascularization patterns were evaluated via DCE-MRI. Results Four neovascularization patterns were observed in glioma tissues. Sprout angiogenesis and intussusceptive microvascular growth located inside tumor, while vascular co-option and vascular mimicry were found in the tumor margin and necrotic area, respectively. Sprout angiogenesis and intussusceptive microvascular growth increased with K trans , K ep , and V p inside tumor tissue. In addition, K ep and V p were positively correlated with sprout angiogenesis and intussusceptive microvascular growth. Vascular co-option was decreased at 12 and 16 days post transplantation and correlated negatively with K trans and K ep detected in the glioma margin, respectively. Changes of vascular mimicry showed no significant statistical difference at the six time points. Conclusion Our results indicate that DCE-MRI can evaluate neovascularization patterns in a glioma model. Furthermore, DCE-MRI could be an imaging biomarker for guidance of antiangiogenic treatments in humans in the future.
NASA Technical Reports Server (NTRS)
Belton, M. J. S.; Aksnes, K.; Davies, M. E.; Hartmann, W. K.; Millis, R. L.; Owen, T. C.; Reilly, T. H.; Sagan, C.; Suomi, V. E.; Collins, S. A., Jr.
1972-01-01
A variety of imaging systems proposed for use aboard the Outer Planet Grand Tour Explorer are discussed and evaluated in terms of optimal resolution capability and efficient time utilization. It is pointed out that the planetary and satellite alignments at the time of encounter dictate a high degree of adaptability and versatility in order to provide sufficient image enhancement over earth-based techniques. Data compression methods are also evaluated according to the same criteria.
Grey-Theory-Based Optimization Model of Emergency Logistics Considering Time Uncertainty.
Qiu, Bao-Jian; Zhang, Jiang-Hua; Qi, Yuan-Tao; Liu, Yang
2015-01-01
Natural disasters occur frequently in recent years, causing huge casualties and property losses. Nowadays, people pay more and more attention to the emergency logistics problems. This paper studies the emergency logistics problem with multi-center, multi-commodity, and single-affected-point. Considering that the path near the disaster point may be damaged, the information of the state of the paths is not complete, and the travel time is uncertainty, we establish the nonlinear programming model that objective function is the maximization of time-satisfaction degree. To overcome these drawbacks: the incomplete information and uncertain time, this paper firstly evaluates the multiple roads of transportation network based on grey theory and selects the reliable and optimal path. Then simplify the original model under the scenario that the vehicle only follows the optimal path from the emergency logistics center to the affected point, and use Lingo software to solve it. The numerical experiments are presented to show the feasibility and effectiveness of the proposed method.
Grey-Theory-Based Optimization Model of Emergency Logistics Considering Time Uncertainty
Qiu, Bao-Jian; Zhang, Jiang-Hua; Qi, Yuan-Tao; Liu, Yang
2015-01-01
Natural disasters occur frequently in recent years, causing huge casualties and property losses. Nowadays, people pay more and more attention to the emergency logistics problems. This paper studies the emergency logistics problem with multi-center, multi-commodity, and single-affected-point. Considering that the path near the disaster point may be damaged, the information of the state of the paths is not complete, and the travel time is uncertainty, we establish the nonlinear programming model that objective function is the maximization of time-satisfaction degree. To overcome these drawbacks: the incomplete information and uncertain time, this paper firstly evaluates the multiple roads of transportation network based on grey theory and selects the reliable and optimal path. Then simplify the original model under the scenario that the vehicle only follows the optimal path from the emergency logistics center to the affected point, and use Lingo software to solve it. The numerical experiments are presented to show the feasibility and effectiveness of the proposed method. PMID:26417946
Almutlak, Mohammed A; Aloniazan, Turki; May, William
2017-01-01
A 55-year-old male presented with reduced vision due to senile cataract. The patient consented to undergo real-time intraoperative anterior segment-optical coherence tomography (AS-OCT) during phacoemulsification with intraocular lens (IOL) implantation. Images were captured at various points during the surgery. The use of AS-OCT incorporated into the surgical microscope was evaluated as an adjunct to cataract surgery. We were able to successfully evaluate, in real-time, wound architecture, the attachment of Descemet's membrane, the posterior capsule, and IOL position. Real-time AS-OCT can be used to proactively address potential complications and verify IOL placement intraoperatively.
Look and Feel: Haptic Interaction for Biomedicine
1995-10-01
algorithm that is evaluated within the topology of the model. During each time step, forces are summed for each mobile atom based on external forces...volumetric properties; (b) conserving computation power by rendering media local to the interaction point; and (c) evaluating the simulation within...alteration of the model topology. Simulation of the DSM state is accomplished by a multi-step algorithm that is evaluated within the topology of the
The UK Earth System Models Marine Biogeochemical Evaluation Toolkit, BGC-val
NASA Astrophysics Data System (ADS)
de Mora, Lee
2017-04-01
The Biogeochemical Validation toolkit, BGC-val, is a model and grid independent python-based marine model evaluation framework that automates much of the validation of the marine component of an Earth System Model. BGC-val was initially developed to be a flexible and extensible system to evaluate the spin up of the marine UK Earth System Model (UKESM). However, the grid-independence and flexibility means that it is straightforward to adapt the BGC-val framework to evaluate other marine models. In addition to the marine component of the UKESM, this toolkit has been adapted to compare multiple models, including models from the CMIP5 and iMarNet inter-comparison projects. The BGC-val toolkit produces multiple levels of analysis which are presented in a simple to use interactive html5 document. Level 1 contains time series analyses, showing the development over time of many important biogeochemical and physical ocean metrics, such as the Global primary production or the Drake passage current. The second level of BGC-val is an in-depth spatial analyses of a single point in time. This is a series of point to point comparison of model and data in various regions, such as a comparison of Surface Nitrate in the model vs data from the world ocean atlas. The third level analyses are specialised ad-hoc packages to go in-depth on a specific question, such as the development of Oxygen minimum zones in the Equatorial Pacific. In additional to the three levels, the html5 document opens with a Level 0 table showing a summary of the status of the model run. The beta version of this toolkit is available via the Plymouth Marine Laboratory Gitlab server and uses the BSD 3 clause license.
Chatiza, F P; Bartels, P; Nedambale, T L; Wagenaar, G M
2012-07-15
The need for information on the reproductive physiology of different wildlife species is important for ex situ conservation using such methods as in vitro fertilization (IVF). Information on species reproductive physiology and evaluation of sperm quality using accurate, objective, repeatable methods, such as computer-assisted sperm analysis (CASA) for ex situ conservation has become a priority. The aim of this study was to evaluate motility patterns of antelope epididymal spermatozoa incubated for 4 h under conditions that support bovine IVF using CASA. Cauda epididymal spermatozoa were collected postmortem from testicles of springbok (N=38), impala (N=26), and blesbok (N=42), and cryopreserved in biladyl containing 7% glycerol. Spermatozoa were thawed and incubated in Capacitation media and modified Tyrode lactate (m-TL) IVF media using a protocol developed for domestic cattle IVF. The study evaluates 14 motility characteristics of the antelope epididymal sperm at six time points using CASA. Species differences in CASA parameters evaluated under similar conditions were observed. Several differences in individual motility parameters at the time points were reported for each species. Epididymal sperm of the different antelope species responded differently to capacitation agents exhibiting variations in hyperactivity. Motility parameters that describe the vigor of sperm decreased over time. Spermatozoa from the different antelope species have different physiological and optimal capacitation and in vitro culture requirements. The interspecies comparison of kinematic parameters of spermatozoa between the antelopes over several end points contributes to comparative sperm physiology which forms an important step in the development of species specific assisted reproductive techniques (ARTs) for ex situ conservation of these species. Copyright © 2012 Elsevier Inc. All rights reserved.
Control of oral malodour by dentifrices measured by gas chromatography.
Newby, Evelyn E; Hickling, Jenneth M; Hughes, Francis J; Proskin, Howard M; Bosma, Marylynn P
2008-04-01
To evaluate the effect of toothpaste treatments on levels of oral volatile sulphur compounds (VSCs) measured by gas chromatography in two clinical studies. These were blinded, randomised, controlled, crossover studies with 16 (study A) or 20 (study B) healthy volunteers between the ages of 19-54. Study A: breath samples were collected at baseline, immediately and lhr after brushing. Four dentifrices (Zinc A, Zinc B, commercially available triclosan dentifrice and zinc free control) were evaluated. Study B: breath samples were collected at baseline, immediately, 1, 2, 3 and 7 hours after treatment. Subjects consumed a light breakfast then provided an additional breath sample between baseline assessment and treatment. Two dentifrices (gel-to-foam and a commercially available triclosan dentrifrice) were evaluated. Breath samples were collected in syringes and analysed for VSCs (hydrogen sulphide, methyl mercaptan and Total VSCs) utilising gas chromatography (GC) with flame photometric detection. Study A: immediately after treatment, a statistically significant reduction in VSCs from baseline was observed for Zinc A product only. A statistically significant reduction in VSCs from baseline was observed after 1 hour for all products. Both zinc products exhibited a significantly greater reduction from baseline VSCs than Colgate Total and Control at all time points. Study B: a statistically significant reduction in VSCs from baseline was observed at all time points for both products. The gel-to-foam product exhibited significantly greater reduction from baseline Total VSC concentration than Colgate Total at all time points from 1 hour post-treatment. Control of oral malodour by toothpaste treatment, evaluated as VSC levels using GC, has been demonstrated. Zinc is effective at reducing VSCs and the efficacy of zinc is formulation dependent. A gel-to-foam dentifrice was more effective at reducing VSCs than Colgate Total up to 7 hours.
Zhu, Lei; Zhang, Cheng; Chuck, Roy S
2012-01-01
To evaluate the effect of the topical steroid, fluorometholone, and the non-steroidal anti-inflammatory drugs (NSAIDs), nepafenac and ketorolac, on inflammatory cytokine expression of the ocular surface in the botulium toxin B-induced murine dry eye model. Topical artificial tears (0.5% carboxymethylcellulose sodium), 0.1% fluorometholone, 0.1% nepafenac, and 0.4% ketorolac were applied 3 times per day in a dry eye mouse model 1 week after intralacrimal botulium toxin B (BTX-B) or saline (sham) injection. Tear production and corneal fluorescein staining were evaluated in all groups before injection at baseline and at 3 time points up to 4 weeks after injection. The pro-inflammatory cytokines interleukin-1β (IL-1β) and tumor necrosis factor-α (TNF-α) were evaluated by immunohistochemistry. BTX-B-injected mice showed significantly decreased aqueous tear production and increased corneal fluorescein staining at the 1 and 2 week time points compared with normal control and saline-injected mice. In the BTX-B-injected mice, immunofluorescent staining for TNF-α and IL-1β in corneal and conjunctival epithelial cells increased significantly at the 2 and 4 week time points compared to that of normal and saline-injected mice, and returned to normal levels at the 4 week time point. Topical fluorometholone significantly improved corneal surface staining in the BTX-B-injected mice after 1 week of treatment, and increased the tear production within 2 weeks, but without statistical significant difference. Topical fluorometholone significantly decreased the staining of TNF-α and IL-1β in corneal and conjunctival epithelia after 1-week treatment. Topical artificial tears, 0.1% nepafenac, and 0.4% ketorolac did not show obvious effects on tear production, corneal surface staining, and levels of IL-1β and TNF-α expression in normal, and BTX-B-injected dry eye mice. Topical fluorometholone caused suppression of inflammatory cytokine expression on the ocular surface in the Botulium toxin B-induced murine dry eye model, while topical NSAIDs demonstrated no clearly beneficial effects.
Honesty on Student Evaluations of Teaching: Effectiveness, Purpose, and Timing Matter!
ERIC Educational Resources Information Center
McClain, Lauren; Gulbis, Angelika; Hays, Donald
2018-01-01
Student evaluations of teaching (SETs) are an important point of assessment for faculty in curriculum development, tenure and promotion decisions, and merit raises. Faculty members utilise SETs to gain feedback on their classes and, hopefully, improve them. The question of the validity of student responses on SETs is a continuing debate in higher…
NASA Astrophysics Data System (ADS)
Nishimaru, Momoko; Nakasa, Miku; Kudo, Shoji; Takiyama, Hiroshi
2017-07-01
Crystallization operation of cocrystal production has deposition risk of undesired crystals. Simultaneously, continuous manufacturing processes are focused on. In this study, conditions for continuous cocrystallization considering risk reduction of undesired crystals deposition were investigated on the view point of thermodynamics and kinetics. The anti-solvent cocrystallization was carried out in four-component system of carbamazepine, saccharin, methanol and water. From the preliminary batch experiment, the relationships among undesired crystal deposition, solution composition decided by mixing ratio of solutions, and residence time for the crystals were considered, and then the conditions of continuous experiment were decided. Under these conditions, the continuous experiment was carried out. The XRD patterns of obtained crystals in the continuous experiment showed that desired cocrystals were obtained without undesired crystals. This experimental result was evaluated by using multi-component phase diagrams from the view point of the operation point's movement. From the evaluation, it was found that there is a certain operation condition which the operation point is fixed with time in the specific domain without the deposition risk of undesired single component crystals. It means the possibility of continuous production of cocrystals without deposition risk of undesired crystals was confirmed by using multi-component phase diagrams.
Wu, Jia-Ni; Zhang, Bi-Ying; Zhu, Wen-Zeng; Du, Ruo-Sang; Liu, Zhi-Shun
2014-06-01
To evaluate preliminarily the efficacy on functional constipation treated with electroacupuncture of different acupoint prescriptions. One hundred and four patients were randomized into a front-mu and back-shu points group (19 cases), a he-sea points group (34 cases), a he-sea, front-mu and back-shu points group (26 cases) and a western medication control group (25 cases). In the front-mu and back-shu points group, electroacupuncture was applied at bilateral Tianshu (ST 25) and Dachangshu (BL 25). In the he-sea points group, electroacupuncture was applied at bilateral Quchi (LI 11) and Shangjuxu (ST 37). In the he-sea, front-mu and back-shu points group, electroacupuncture was applied at unilateral Tianshu (ST 25), Dachangshu (BL 25), Quchi (LI 11) and Shangjuxu (ST 37). In the three groups above, the treatment was given 5 times a week in the first two weeks and 3 times a week in the next two weeks. In the western medication control group, mosapride citrate tablets were prescribed for oral administration, 1 table (5 mg) each time, 3 times a day, continuously for 4 weeks. The period of research was 9 weeks, including 1 week for baseline evaluation, 4 weeks for treatment and 4 weeks for follow-up. The weekly defecation frequency was taken as primary index, while the defecation difficulty and life quality score were taken as the secondary indices for the efficacy evaluation after treatment and in follow-up. According to the intention-to-treat (ITT) analytic principle, 104 cases were all enrolled in the final analysis. (1) After treatment, the weekly frequency of defecation was all increased significantly in the four groups (P < 0.05, P < 0.01). The efficacy of the three electroacupuncture groups was similar to that of western medication control group (P > 0.05). In follow-up, the increasing effect on the weekly frequency of defecation was maintained in the he-sea points group (P < 0.01), superior to the front-mu and back-shu points group and the western medication control group (P < 0.05, P < 0.01); the weekly frequency of defecation was not improved in the rest three groups (P > 0.05). (2) After treatment, defecation difficulty was relieved in the he-sea points group, the he-sea, front-mu and back-shu points group and the western medication control group (P < 0.05, P < 0.01). In follow-up, the improvements were still significant in the he-sea points group and the he-sea, front-mu and back-shu points group (both P < 0.01). (3) After treatment, the life quality score was significantly improved in the patients of the he-sea points group (P < 0.05). The difference was not significant in the rest three groups as compared with that before treatment (all P > 0.05). The weekly frequency of defecation is increased effectively after treatment in the three electroacupuncture groups and the efficacy is similar to mosapride citrate tablets. The bilateral Quchi (LI 11) and Shangjuxu (ST 37) in he-sea acupoints increase significantly the weekly frequency of defecation, relieve defecation difficulty and improve life quality. Acupuncture efficacy is sustained for 4 weeks. This acupoints prescription is the best in the treatment of functional constipation.
NASA Astrophysics Data System (ADS)
Syusina, O. M.; Chernitsov, A. M.; Tamarov, V. A.
2011-07-01
The combined method for mapping of the confidence region of the motion of the small bodies of Solar system at any point in time is proposed. In this method firstly one carries out linear mapping of the initial region at given point in time. If nonlinear-ity coefficient of evaluated region provided to be larger of permissible ones, that one carries out linear mapping of the initial region at limit moment for which this region be ellipsoidal. After that obtained region is mapping at given point in time by nonlinear method.
Response to depression treatment in the Aging Brain Care Medical Home model.
LaMantia, Michael A; Perkins, Anthony J; Gao, Sujuan; Austrom, Mary G; Alder, Cathy A; French, Dustin D; Litzelman, Debra K; Cottingham, Ann H; Boustani, Malaz A
2016-01-01
To evaluate the effect of the Aging Brain Care (ABC) Medical Home program's depression module on patients' depression severity measurement over time. Retrospective chart review. Public hospital system. Patients enrolled in the ABC Medical Home program between October 1, 2012 and March 31, 2014. The response of 773 enrolled patients who had multiple patient health questionnaire-9 (PHQ-9) scores recorded in the ABC Medical Home program's depression care protocol was evaluated. Repeatedly measured PHQ-9 change scores were the dependent variables in the mixed effects models, and demographic and comorbid medical conditions were tested as potential independent variables while including random effects for time and intercept. Among those patients with baseline PHQ-9 scores >10, there was a significant decrease in PHQ-9 scores over time ( P <0.001); however, the effect differed by gender ( P =0.015). On average, women's scores (4.5 point drop at 1 month) improved faster than men's scores (1 point drop at 1 month). Moreover, both men and women had a predicted drop of 7 points (>50% decline from baseline) on the PHQ-9 at 6 months. These analyses demonstrate evidence for the sustained effectiveness of the ABC Medical Home program at inducing depression remission outcomes while employing clinical staff who required less formal training than earlier clinical trials.
Effects of Eddy Viscosity on Time Correlations in Large Eddy Simulation
NASA Technical Reports Server (NTRS)
He, Guowei; Rubinstein, R.; Wang, Lian-Ping; Bushnell, Dennis M. (Technical Monitor)
2001-01-01
Subgrid-scale (SGS) models for large. eddy simulation (LES) have generally been evaluated by their ability to predict single-time statistics of turbulent flows such as kinetic energy and Reynolds stresses. Recent application- of large eddy simulation to the evaluation of sound sources in turbulent flows, a problem in which time, correlations determine the frequency distribution of acoustic radiation, suggest that subgrid models should also be evaluated by their ability to predict time correlations in turbulent flows. This paper compares the two-point, two-time Eulerian velocity correlation evaluated from direct numerical simulation (DNS) with that evaluated from LES, using a spectral eddy viscosity, for isotropic homogeneous turbulence. It is found that the LES fields are too coherent, in the sense that their time correlations decay more slowly than the corresponding time. correlations in the DNS fields. This observation is confirmed by theoretical estimates of time correlations using the Taylor expansion technique. Tile reason for the slower decay is that the eddy viscosity does not include the random backscatter, which decorrelates fluid motion at large scales. An effective eddy viscosity associated with time correlations is formulated, to which the eddy viscosity associated with energy transfer is a leading order approximation.
An acute stroke evaluation app: a practice improvement project.
Rubin, Mark N; Fugate, Jennifer E; Barrett, Kevin M; Rabinstein, Alejandro A; Flemming, Kelly D
2015-04-01
A point-of-care workflow checklist in the form of an iOS (iPhone Operating System) app for use by stroke providers was introduced with the objective of standardizing acute stroke evaluation and documentation at 2 affiliated academic medical centers. Providers used the app in unselected, consecutive patients undergoing acute stroke evaluation in an emergency department or hospital setting between August 2012 and January 2013 and August 2013 and February 2014. Satisfaction surveys were prospectively collected pre- and postintervention from residents, staff neurologists, and clinical data specialists. Residents (20 preintervention and 16 postintervention), staff neurologists (6 pre and 5 post), and clinical data specialists (4 pre and 4 post) participated in this study. All 16 (100%) residents had increased satisfaction with their ability to perform an acute stroke evaluation postintervention but only 9 (56%) of 16 felt the app was more help than hindrance. Historical controls aligned with preintervention results. Staff neurologists conveyed increased satisfaction with resident presentations and decision making when compared to preintervention surveys. Stroke clinical data specialists estimated a 50% decrease in data abstraction when the app data were used in the clinical note. Concomitant effect on door-to-needle (DTN) time at 1 site, although not a primary study measure, was also evaluated. At that 1 center, the mean DTN time decreased by 16 minutes when compared to the corresponding months from the year prior. The point-of-care acute stroke workflow checklist app may assist trainees in presenting findings in a standardized manner and reduce data abstraction time. The app may help reduce DTN time, but this requires further study.
The lead time tradeoff: the case of health states better than dead.
Pinto-Prades, José Luis; Rodríguez-Míguez, Eva
2015-04-01
Lead time tradeoff (L-TTO) is a variant of the time tradeoff (TTO). L-TTO introduces a lead period in full health before illness onset, avoiding the need to use 2 different procedures for states better and worse than dead. To estimate utilities, additive separability is assumed. We tested to what extent violations of this assumption can bias utilities estimated with L-TTO. A sample of 500 members of the Spanish general population evaluated 24 health states, using face-to-face interviews. A total of 188 subjects were interviewed with L-TTO and the rest with TTO. Both samples evaluated the same set of 24 health states, divided into 4 groups with 6 health states per set. Each subject evaluated 1 of the sets. A random effects regression model was fitted to our data. Only health states better than dead were included in the regression since it is in this subset where additive separability can be tested clearly. Utilities were higher in L-TTO in relation to TTO (on average L-TTO adds about 0.2 points to the utility of health states), suggesting that additive separability is violated. The difference between methods increased with the severity of the health state. Thus, L-TTO adds about 0.14 points to the average utility of the less severe states, 0.23 to the intermediate states, and 0.28 points to the more severe estates. L-TTO produced higher utilities than TTO. Health problems are perceived as less severe if a lead period in full health is added upfront, implying that there are interactions between disjointed time periods. The advantages of this method have to be compared with the cost of modeling the interaction between periods. © The Author(s) 2014.
Shanafelt, Tait D; Mungo, Michelle; Schmitgen, Jaime; Storz, Kristin A; Reeves, David; Hayes, Sharonne N; Sloan, Jeff A; Swensen, Stephen J; Buskirk, Steven J
2016-04-01
To longitudinally evaluate the relationship between burnout and professional satisfaction with changes in physicians' professional effort. Administrative/payroll records were used to longitudinally evaluate the professional work effort of faculty physicians working for Mayo Clinic from October 1, 2008, to October 1, 2014. Professional effort was measured in full-time equivalent (FTE) units. Physicians were longitudinally surveyed in October 2011 and October 2013 with standardized tools to assess burnout and satisfaction. Between 2008 and 2014, the proportion of physicians working less than full-time at our organization increased from 13.5% to 16.0% (P=.05). Of the 2663 physicians surveyed in 2011 and 2776 physicians surveyed in 2013, 1856 (69.7%) and 2132 (76.9%), respectively, returned surveys. Burnout and satisfaction scores in 2011 correlated with actual reductions in FTE over the following 24 months as independently measured by administrative/payroll records. After controlling for age, sex, site, and specialty, each 1-point increase in the 7-point emotional exhaustion scale was associated with a greater likelihood of reducing FTE (odds ratio [OR], 1.43; 95% CI, 1.23-1.67; P<.001) over the following 24 months, and each 1-point decrease in the 5-point satisfaction score was associated with greater likelihood of reducing FTE (OR, 1.34; 95% CI, 1.03-1.74; P=.03). On longitudinal analysis at the individual physician level, each 1-point increase in emotional exhaustion (OR, 1.28; 95% CI, 1.05-1.55; P=.01) or 1-point decrease in satisfaction (OR, 1.67; 95% CI, 1.19-2.35; P=.003) between 2011 and 2013 was associated with a greater likelihood of reducing FTE over the following 12 months. Among physicians in a large health care organization, burnout and declining satisfaction were strongly associated with actual reductions in professional work effort over the following 24 months. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Hwang, Jae Joon; Kim, Kee-Deog; Park, Hyok; Park, Chang Seo; Jeong, Ho-Gul
2014-01-01
Superimposition has been used as a method to evaluate the changes of orthodontic or orthopedic treatment in the dental field. With the introduction of cone beam CT (CBCT), evaluating 3 dimensional changes after treatment became possible by superimposition. 4 point plane orientation is one of the simplest ways to achieve superimposition of 3 dimensional images. To find factors influencing superimposition error of cephalometric landmarks by 4 point plane orientation method and to evaluate the reproducibility of cephalometric landmarks for analyzing superimposition error, 20 patients were analyzed who had normal skeletal and occlusal relationship and took CBCT for diagnosis of temporomandibular disorder. The nasion, sella turcica, basion and midpoint between the left and the right most posterior point of the lesser wing of sphenoidal bone were used to define a three-dimensional (3D) anatomical reference co-ordinate system. Another 15 reference cephalometric points were also determined three times in the same image. Reorientation error of each landmark could be explained substantially (23%) by linear regression model, which consists of 3 factors describing position of each landmark towards reference axes and locating error. 4 point plane orientation system may produce an amount of reorientation error that may vary according to the perpendicular distance between the landmark and the x-axis; the reorientation error also increases as the locating error and shift of reference axes viewed from each landmark increases. Therefore, in order to reduce the reorientation error, accuracy of all landmarks including the reference points is important. Construction of the regression model using reference points of greater precision is required for the clinical application of this model.
NASA Technical Reports Server (NTRS)
Choudhary, Alok Nidhi; Leung, Mun K.; Huang, Thomas S.; Patel, Janak H.
1989-01-01
Computer vision systems employ a sequence of vision algorithms in which the output of an algorithm is the input of the next algorithm in the sequence. Algorithms that constitute such systems exhibit vastly different computational characteristics, and therefore, require different data decomposition techniques and efficient load balancing techniques for parallel implementation. However, since the input data for a task is produced as the output data of the previous task, this information can be exploited to perform knowledge based data decomposition and load balancing. Presented here are algorithms for a motion estimation system. The motion estimation is based on the point correspondence between the involved images which are a sequence of stereo image pairs. Researchers propose algorithms to obtain point correspondences by matching feature points among stereo image pairs at any two consecutive time instants. Furthermore, the proposed algorithms employ non-iterative procedures, which results in saving considerable amounts of computation time. The system consists of the following steps: (1) extraction of features; (2) stereo match of images in one time instant; (3) time match of images from consecutive time instants; (4) stereo match to compute final unambiguous points; and (5) computation of motion parameters.
Beckers, Stefan; Fries, Michael; Bickenbach, Johannes; Derwall, Matthias; Kuhlen, Ralf; Rossaint, Rolf
2005-01-01
Introduction There is evidence that use of automated external defibrillators (AEDs) by laypersons improves rates of survival from cardiac arrest, but there is no consensus on the optimal content and duration of training for this purpose. In this study we examined the use of semiautomatic or automatic AEDs by laypersons who had received no training (intuitive use) and the effects of minimal general theoretical instructions on their performance. Methods In a mock cardiac arrest scenario, 236 first year medical students who had not previously attended any preclinical courses were evaluated in their first study week, before and after receiving prespecified instructions (15 min) once. The primary end-point was the time to first shock for each time point; secondary end-points were correct electrode pad positioning, safety of the procedure and the subjective feelings of the students. Results The mean time to shock for both AED types was 81.2 ± 19.2 s (range 45–178 s). Correct pad placement was observed in 85.6% and adequate safety in 94.1%. The time to shock after instruction decreased significantly to 56.8 ± 9.9 s (range 35–95 s; P ≤ 0.01), with correct electrode placement in 92.8% and adequate safety in 97%. The students were significantly quicker at both evaluations using the semiautomatic device than with the automatic AED (first evaluation: 77.5 ± 20.5 s versus 85.2 ± 17 s, P ≤ 0.01; second evaluation: 55 ± 10.3 s versus 59.6 ± 9.6 s, P ≤ 0.01). Conclusion Untrained laypersons can use semiautomatic and automatic AEDs sufficiently quickly and without instruction. After one use and minimal instructions, improvements in practical performance were significant. All tested laypersons were able to deliver the first shock in under 1 min. PMID:15774042
NASA Astrophysics Data System (ADS)
Eduardo Virgilio Silva, Luiz; Otavio Murta, Luiz
2012-12-01
Complexity in time series is an intriguing feature of living dynamical systems, with potential use for identification of system state. Although various methods have been proposed for measuring physiologic complexity, uncorrelated time series are often assigned high values of complexity, errouneously classifying them as a complex physiological signals. Here, we propose and discuss a method for complex system analysis based on generalized statistical formalism and surrogate time series. Sample entropy (SampEn) was rewritten inspired in Tsallis generalized entropy, as function of q parameter (qSampEn). qSDiff curves were calculated, which consist of differences between original and surrogate series qSampEn. We evaluated qSDiff for 125 real heart rate variability (HRV) dynamics, divided into groups of 70 healthy, 44 congestive heart failure (CHF), and 11 atrial fibrillation (AF) subjects, and for simulated series of stochastic and chaotic process. The evaluations showed that, for nonperiodic signals, qSDiff curves have a maximum point (qSDiffmax) for q ≠1. Values of q where the maximum point occurs and where qSDiff is zero were also evaluated. Only qSDiffmax values were capable of distinguish HRV groups (p-values 5.10×10-3, 1.11×10-7, and 5.50×10-7 for healthy vs. CHF, healthy vs. AF, and CHF vs. AF, respectively), consistently with the concept of physiologic complexity, and suggests a potential use for chaotic system analysis.
NASA Astrophysics Data System (ADS)
Schmidt, J. B.
1985-09-01
This thesis investigates ways of improving the real-time performance of the Stockpoint Logistics Integrated Communication Environment (SPLICE). Performance evaluation through continuous monitoring activities and performance studies are the principle vehicles discussed. The method for implementing this performance evaluation process is the measurement of predefined performance indexes. Performance indexes for SPLICE are offered that would measure these areas. Existing SPLICE capability to carry out performance evaluation is explored, and recommendations are made to enhance that capability.
Using simplified Chaos Theory to manage nursing services.
Haigh, Carol A
2008-04-01
The purpose of this study was to evaluate the part simplified chaos theory could play in the management of nursing services. As nursing care becomes more complex, practitioners need to become familiar with business planning and objective time management. There are many time-limited methods that facilitate this type of planning but few that can help practitioners to forecast the end-point outcome of the service they deliver. A growth model was applied to a specialist service to plot service trajectory. Components of chaos theory can play a role in forecasting service outcomes and consequently the impact upon the management of such services. The ability to (1) track the trajectory of a service and (2) manipulate that trajectory by introducing new variables can allow managers to forward plan for service development and to evaluate the effectiveness of a service by plotting its end-point state.
Pulse-echo ultrasonic imaging method for eliminating sample thickness variation effects
NASA Technical Reports Server (NTRS)
Roth, Don J. (Inventor)
1995-01-01
A pulse-echo, immersion method for ultrasonic evaluation of a material is discussed. It accounts for and eliminates nonlevelness in the equipment set-up and sample thickness variation effects employs a single transducer, automatic scanning and digital imaging to obtain an image of a property of the material, such as pore fraction. The nonlevelness and thickness variation effects are accounted for by pre-scan adjusments of the time window to insure that the echoes received at each scan point are gated in the center of the window. This information is input into the scan file so that, during the automatic scanning for the material evaluation, each received echo is centered in its time window. A cross-correlation function calculates the velocity at each scan point, which is then proportionalized to a color or grey scale and displayed on a video screen.
User data dissemination concepts for earth resources
NASA Technical Reports Server (NTRS)
Davies, R.; Scott, M.; Mitchell, C.; Torbett, A.
1976-01-01
Domestic data dissemination networks for earth-resources data in the 1985-1995 time frame were evaluated. The following topics were addressed: (1) earth-resources data sources and expected data volumes, (2) future user demand in terms of data volume and timeliness, (3) space-to-space and earth point-to-point transmission link requirements and implementation, (4) preprocessing requirements and implementation, (5) network costs, and (6) technological development to support this implementation. This study was parametric in that the data input (supply) was varied by a factor of about fifteen while the user request (demand) was varied by a factor of about nineteen. Correspondingly, the time from observation to delivery to the user was varied. This parametric evaluation was performed by a computer simulation that was based on network alternatives and resulted in preliminary transmission and preprocessing requirements. The earth-resource data sources considered were: shuttle sorties, synchronous satellites (e.g., SEOS), aircraft, and satellites in polar orbits.
Li, Hui
2009-11-14
Linear response and variational treatment are formulated for Hartree-Fock (HF) and Kohn-Sham density functional theory (DFT) methods and combined discrete-continuum solvation models that incorporate self-consistently induced dipoles and charges. Due to the variational treatment, analytic nuclear gradients can be evaluated efficiently for these discrete and continuum solvation models. The forces and torques on the induced point dipoles and point charges can be evaluated using simple electrostatic formulas as for permanent point dipoles and point charges, in accordance with the electrostatic nature of these methods. Implementation and tests using the effective fragment potential (EFP, a polarizable force field) method and the conductorlike polarizable continuum model (CPCM) show that the nuclear gradients are as accurate as those in the gas phase HF and DFT methods. Using B3LYP/EFP/CPCM and time-dependent-B3LYP/EFP/CPCM methods, acetone S(0)-->S(1) excitation in aqueous solution is studied. The results are close to those from full B3LYP/CPCM calculations.
2012-04-01
time , crystal frequency, temperature, and headspace oxygen concentration. 41 Approved for public release; distribution unlimited. C-4. Fuels: In...at ambient pressure. At this point the heater, which is set at 140 °C, is turned on and computer data acquisition is begun. The run time , crystal frequency
Water content measurement in forest soils and decayed wood using time domain reflectometry
Andrew Gray; Thomas Spies
1995-01-01
The use of time domain reflectometry to measure moisture content in forest soils and woody debris was evaluated. Calibrations were developed on undisturbed soil cores from four forest stands and on point samples from decayed logs. An algorithm for interpreting irregularly shaped traces generated by the reflectometer was also developed. Two different calibration...
A Few Observations and Remarks on Time Effectiveness of Interactive Electronic Testing
ERIC Educational Resources Information Center
Magdin, Martin; Turcáni, Milan
2015-01-01
In the paper, we point out several observations and remarks on time effectiveness of electronic testing, in particular of its new form (interactive tests). A test is often used as an effective didactic tool for evaluating the extent of gained cognitive capabilities. According to authors Rudman (1989) and Wang (2003) it is provable that the…
Term-Time Employment and the Academic Performance of Undergraduates
ERIC Educational Resources Information Center
Wenz, Michael; Yu, Wei-Choun
2010-01-01
This article outlines a framework for evaluating the decision of undergraduate students to engage in term-time employment as a method of financing higher education. We then examine the impact of work on academic achievement and find that employment has modest negative effects on student grades, with a grade point average (GPA) falling by 0.007…
Longitudinal changes in intellectual development in children with Fragile X syndrome.
Hall, Scott S; Burns, David D; Lightbody, Amy A; Reiss, Allan L
2008-08-01
Structural equation modeling (SEM) was used to examine the development of intellectual functioning in 145 school-age pairs of siblings. Each pair included one child with Fragile X syndrome (FXS) and one unaffected sibling. All pairs of children were evaluated on the Wechsler Intelligence Scale for Children-Third Edition (WISC-III) at time 1 and 80 pairs of children received a second evaluation at time 2 approximately 4 years later. Compared to their unaffected siblings, children with FXS obtained significantly lower percentage correct scores on all subtests of the WISC at both time points. During the time between the first and second assessments, the annual rate of intellectual development was approximately 2.2 times faster in the unaffected children compared to the children with FXS. Levels of the fragile X mental retardation protein (FMRP) were highly associated with intellectual ability scores of the children with FXS at both time points (r=0.55 and 0.64 respectively). However, when gender, age, and the time between assessments were included as covariates in the structural equation model, FMRP accounted for only 5% of the variance in intellectual ability scores at time 1 and 13% of the variance at time 2. The results of this study suggest that slower learning contributes to the low and declining standardized IQ scores observed in children with FXS.
Characteristic Boundary Conditions for ARO-1
1983-05-01
I As shown in Fig. 3, the point designated II is the interior point that was used to define the barred coordinate system , evaluated at time t=. All...L. Jacocks Calspan Field Services, Inc. May 1983 Final Report for Period October 1981 - September 1982 r Approved for public release; destribut ...on unlimited I ARNOLD ENGINEERING DEVELOPMENT CENTER ARNOLD AIR FORCE STATION, TENNESSEE AIR FORCE SYSTEMS COMMAND UNITED STATES AIR FORCE N O T I
Nomura, Sarah J O; Dash, Chiranjeev; Rosenberg, Lynn; Yu, Jeffrey; Palmer, Julie R; Adams-Campbell, Lucile L
2016-07-01
The purpose of this study was to evaluate whether adherence to the World Cancer Research Fund/American Institute for Cancer Research (WCRF/AICR) cancer prevention recommendations was associated with colorectal cancer incidence in the Black Women's Health Study (BWHS). In this ongoing prospective cohort of African American women (analytic cohort n = 49,103), 354 incident colorectal cancers were diagnosed between baseline (1995) and 2011. Adherence scores for seven WCRF/AICR recommendations (adherent = 1 point, non-adherent level 1 = 0.5 points, non-adherent level 2 = 0 points) were created using questionnaire data and summed to an overall adherence score (maximum = 7). Recommendation adherence and colorectal cancer incidence were evaluated using baseline and time-varying data in Cox regression models. At baseline, 8.5 % of women adhered >4 recommendations. In time-varying analyses, the HR was 0.98 (95 % CI 0.84-1.15) per 0.5 point higher score and 0.51 (95 % CI 0.23-1.10) for adherence to >4 compared to <3 recommendations. Adherence to individual recommendations was not associated with colorectal cancer risk. Results were similar in models that considered baseline exposures only. Adherence to cancer prevention recommendations was low and not associated with colorectal cancer risk among women in the BWHS. Research in diverse populations is essential to evaluate the validity of existing recommendations, and assess whether there are alternative recommendations that are more beneficial for cancer prevention in specific populations.
Romualdo, Guilherme Ribeiro; Goto, Renata Leme; Henrique Fernandes, Ana Angélica; Cogliati, Bruno; Barbisan, Luis Fernando
2016-10-01
Although there is a concomitance of zinc deficiency and high incidence/mortality for hepatocellular carcinoma in certain human populations, there are no experimental studies investigating the modifying effects of zinc on hepatocarcinogenesis. Thus, we evaluated whether dietary zinc deficiency or supplementation alter the development of hepatocellular preneoplastic lesions (PNL). Therefore, neonatal male Balb/C mice were submitted to a diethylnitrosamine/2-acetylaminefluorene-induced hepatocarcinogenesis model. Moreover, mice were fed adequate (35 mg/kg diet), deficient (3 mg/kg) or supplemented (180 mg/kg) zinc diets. Mice were euthanized at 12 (early time-point) or 24 weeks (late time-point) after introducing the diets. At the early time-point, zinc deficiency decreased Nrf2 protein expression and GSH levels while increased p65 and p53 protein expression and the number of PNL/area. At the late time-point, zinc deficiency also decreased GSH levels while increased liver genotoxicity, cell proliferation into PNL and PNL size. In contrast, zinc supplementation increased antioxidant defense at both time-points but not altered PNL development. Our findings are the first to suggest that zinc deficiency predisposes mice to the PNL development in chemically-induced hepatocarcinogenesis. The decrease of Nrf2/GSH pathway and increase of liver genotoxicity, as well as the increase of p65/cell proliferation, are potential mechanisms to this zinc deficiency-mediated effect. Copyright © 2016 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Fekkes, M.; van de Sande, M. C. E.; Gravesteijn, J. C.; Pannebakker, F. D.; Buijs, G. J.; Diekstra, R. F. W.; Kocken, P. L.
2016-01-01
Purpose: The purpose of this paper is to evaluate the effects of the Dutch "Skills for Life" programme on students' health behaviours, bullying behaviour and suicidal ideation. Design/methodology/approach: The effectiveness of the "Skills for Life" programme on health behaviour outcomes was evaluated at three points in time in…
Dynamics and control simulation of the Spacelab Experiment Pointing Mount
NASA Technical Reports Server (NTRS)
Marsh, E. L.; Ward, R. S.
1977-01-01
Computer simulations were developed to evaluate the performance of four Experiment Pointing Mounts (EPM) being considered for Spacelab experiments in the 1980-1990 time frame. The system modeled compromises a multibody system consisting of the shuttle, a mechanical isolation device, the EPM, celestial and inertial sensors, bearings, gimbal torque motors and associated nonlinearities, the experiment payload, and control and estimator algorithms. Each mount was subjected to a common disturbance (shuttle vernier thruster firing and man push off) and command (stellar pointing or solar raster scan) input. The fundamental limitation common to all mounts was found to be sensor noise. System dynamics and hardware nonlinearities have secondary effects on pointing performance for sufficiently high bandwidth.
Traverzim, Maria Aparecida Dos Santos; Makabe, Sergio; Silva, Daniela Fátima Teixeira; Pavani, Christiane; Bussadori, Sandra Kalil; Fernandes, Kristianne Santos Porta; Motta, Lara Jansiski
2018-06-01
Labor pain is one of the most intense pains experienced by women, which leads to an increase in the number of women opting to undergo a cesarean delivery. Pharmacological and nonpharmacological analgesia methods are used to control labor pain. Epidural analgesia is the most commonly used pharmacological analgesia method. However, it may have side effects on the fetus and the mother. Light-emitting diode (LED) photobiomodulation is an effective and noninvasive alternative to pharmacological methods. To evaluate the effects of LED photobiomodulation on analgesia during labor. In total, 60 women in labor admitted to a public maternity hospital will be selected for a randomized controlled trial. The participants will be randomized into 2 groups: intervention group [analgesia with LED therapy (n = 30)] and control group [analgesia with bath therapy (n = 30)]. The perception of pain will be assessed using the visual analogue scale (VAS), with a score from 0 to 10 at baseline, that is, before the intervention. In both the groups, the procedures will last 10 minutes and will be performed at 3 time points during labor: during cervical dilation of 4 to 5 cm, 6 to 7 cm, and 8 to 9 cm. At all 3 time points, pain perception will be evaluated using VAS shortly after the intervention. In addition, the evaluation of membrane characteristics (intact or damaged), heart rate, uterine dynamics, and cardiotocography will be performed at all time points. The use of LED photobiomodulation will have an analgesic effect superior to that of the bath therapy.
Evaluation of Point-of-Care Resources for Dietary Supplement Information.
Montgomery, Ashley E; Beckett, Robert D; Montagano, Kaitlin J; Kutom, Samah
2018-01-01
To evaluate 6 tertiary, point-of-care drug information resources' dietary supplement content. This was a cross-sectional evaluation of Lexicomp Natural Products Database, Micromedex Alternative Medicine, Clinical Pharmacology, Natural Medicines, The Review of Natural Products, and Handbook of Nonprescription Drugs. Each resource was evaluated for scope, completeness, consistency, and ease of use. For a sample of 66 supplements, scope scores ranged from 69.7% (Micromedex) to 100% (Natural Medicines). Completeness scores were high considering uses, dose, adverse effects, and mechanism (85.7% to 100%). Overall completeness scores ranged from 82.5% ( Handbook of Nonprescription Drugs) to 100% (Clinical Pharmacology, Natural Medicines, The Review of Natural Products). Consistency scores ranged from 0% ( Handbook of Nonprescription Drugs) to 100% (Natural Medicines, The Review of Natural Products). Mean time to locate and gather information was similar among groups. Resources were similar for completeness and ease of use. Scope and consistency varied depending on the resource.
Geerse, Daphne J; Coolen, Bert H; Roerdink, Melvyn
2015-01-01
Walking ability is frequently assessed with the 10-meter walking test (10MWT), which may be instrumented with multiple Kinect v2 sensors to complement the typical stopwatch-based time to walk 10 meters with quantitative gait information derived from Kinect's 3D body point's time series. The current study aimed to evaluate a multi-Kinect v2 set-up for quantitative gait assessments during the 10MWT against a gold-standard motion-registration system by determining between-systems agreement for body point's time series, spatiotemporal gait parameters and the time to walk 10 meters. To this end, the 10MWT was conducted at comfortable and maximum walking speed, while 3D full-body kinematics was concurrently recorded with the multi-Kinect v2 set-up and the Optotrak motion-registration system (i.e., the gold standard). Between-systems agreement for body point's time series was assessed with the intraclass correlation coefficient (ICC). Between-systems agreement was similarly determined for the gait parameters' walking speed, cadence, step length, stride length, step width, step time, stride time (all obtained for the intermediate 6 meters) and the time to walk 10 meters, complemented by Bland-Altman's bias and limits of agreement. Body point's time series agreed well between the motion-registration systems, particularly so for body points in motion. For both comfortable and maximum walking speeds, the between-systems agreement for the time to walk 10 meters and all gait parameters except step width was high (ICC ≥ 0.888), with negligible biases and narrow limits of agreement. Hence, body point's time series and gait parameters obtained with a multi-Kinect v2 set-up match well with those derived with a gold standard in 3D measurement accuracy. Future studies are recommended to test the clinical utility of the multi-Kinect v2 set-up to automate 10MWT assessments, thereby complementing the time to walk 10 meters with reliable spatiotemporal gait parameters obtained objectively in a quick, unobtrusive and patient-friendly manner.
NASA Astrophysics Data System (ADS)
Spaans, K.; Hooper, A. J.
2017-12-01
The short revisit time and high data acquisition rates of current satellites have resulted in increased interest in the development of deformation monitoring and rapid disaster response capability, using InSAR. Fast, efficient data processing methodologies are required to deliver the timely results necessary for this, and also to limit computing resources required to process the large quantities of data being acquired. Contrary to volcano or earthquake applications, urban monitoring requires high resolution processing, in order to differentiate movements between buildings, or between buildings and the surrounding land. Here we present Rapid time series InSAR (RapidSAR), a method that can efficiently update high resolution time series of interferograms, and demonstrate its effectiveness over urban areas. The RapidSAR method estimates the coherence of pixels on an interferogram-by-interferogram basis. This allows for rapid ingestion of newly acquired images without the need to reprocess the earlier acquired part of the time series. The coherence estimate is based on ensembles of neighbouring pixels with similar amplitude behaviour through time, which are identified on an initial set of interferograms, and need be re-evaluated only occasionally. By taking into account scattering properties of points during coherence estimation, a high quality coherence estimate is achieved, allowing point selection at full resolution. The individual point selection maximizes the amount of information that can be extracted from each interferogram, as no selection compromise has to be reached between high and low coherence interferograms. In other words, points do not have to be coherent throughout the time series to contribute to the deformation time series. We demonstrate the effectiveness of our method over urban areas in the UK. We show how the algorithm successfully extracts high density time series from full resolution Sentinel-1 interferograms, and distinguish clearly between buildings and surrounding vegetation or streets. The fact that new interferograms can be processed separately from the remainder of the time series helps manage the high data volumes, both in space and time, generated by current missions.
The results obtained from evaluating ten GAC POE (point-of-entry) devices show that while these GAC units generally function very satisfactorily, their performance can change markedly over short periods of time.
Grade inflation at a north american college of veterinary medicine: 1985-2006.
Rush, Bonnie R; Elmore, Ronnie G; Sanderson, Michael W
2009-01-01
Grade inflation, an upward shift in student grade-point averages without a similar rise in achievement, is considered pervasive by most experts in post-secondary education in the United States. Grade-point averages (GPAs) at US universities have increased by roughly 0.15 points per decade since the 1960s, with a 0.6-point increase since 1967. In medical education, grade inflation has been documented and is particularly evident in the clinical setting. The purpose of this study was to evaluate grade inflation over a 22-year period in a college of veterinary medicine. Academic records from 2,060 students who graduated from the College of Veterinary Medicine at Kansas State University between 1985 and 2006 were evaluated, including cumulative GPAs earned during pre-clinical professional coursework, during clinical rotations, and at graduation. Grade inflation was documented at a rate of approximately 0.2 points per decade at this college of veterinary medicine. The difference in mean final GPA between the minimum (1986) and maximum (2003) years of graduation was 0.47 points. Grade inflation was similar for didactic coursework (years 1-3) and clinical rotations (final year). Demographic shifts, student qualifications, and tuition do not appear to have contributed to grade inflation over time. A change in academic standards and student evaluation of teaching may have contributed to relaxed grading standards, and technology in the classroom may have led to higher (earned) grades as a result of improved student learning.
Does point-of-care functional echocardiography enhance cardiovascular care in the NICU?
Sehgal, A; McNamara, P J
2008-11-01
Although the last two decades have seen major advances in the care of sick, extremely premature newborns, the approach to cardiovascular assessment and monitoring remains suboptimal owing to an overreliance on poorly predictive clinical markers such as heart rate or capillary refill time. Point-of-care functional echocardiography (PCFecho) enables real-time evaluation of cardiac performance and systemic hemodynamics to characterize acute physiology, identify the exact nature of cardiovascular compromise and guide therapeutic decisions. In this article, we will review four clinical scenarios where bedside functional cardiac imaging enabled delineation of the real clinical problem and refinement of the therapeutic care plan with direct patient benefits.
HAKIM, Hakimullah; TOYOFUKU, Chiharu; OTA, Mari; SUZUKI, Mayuko; KOMURA, Miyuki; YAMADA, Masashi; ALAM, Md. Shahin; SANGSRIRATANAKUL, Natthanan; SHOHAM, Dany; TAKEHARA, Kazuaki
2016-01-01
An alkaline agent, namely food additive grade calcium hydroxide (FdCa (OH)2) in the powder form, was evaluated for its bactericidal efficacies in chicken feces at pH 13. The point for this evaluation was neutralization of the alkaline agent’s pH at the time of bacterial recovery, since otherwise the results are substantially misleading. Without neutralization of the FdCa (OH)2 pH, the spiked bacteria were killed within min at the time of recovery in aqueous phase, but not in the solid form in feces, hence, it has been demonstrated that when bacteria were in solid, it took longer time than in liquid for the alkaline agent to inactivate them down to the acceptable level (≥3 log10 CFU/ml). PMID:27890906
Channel morphodynamics in four reaches of the Lower Missouri River, 2006-07
Elliott, Caroline M.; Reuter, Joanna M.; Jacobson, Robert B.
2009-01-01
Channel morphodynamics in response to flow modifications from Gavins Point Dam are examined in four reaches of the Lower Missouri River. Measures include changes in channel morphology and indicators of sediment transport in four 6 kilometer long reaches located downstream from Gavins Point Dam, near Yankton, South Dakota, Kenslers Bend, Nebraska, Little Sioux, Iowa, and Miami, Missouri. Each of the four reaches was divided into 300 transects with a 20-meter spacing and surveyed during the summer in 2006 and 2007. A subset of 30 transects was randomly selected and surveyed 7-10 times in 2006-07 over a wide range of discharges including managed and natural flow events. Hydroacoustic mapping used a survey-grade echosounder and a Real Time Kinematic Global Positioning System to evaluate channel change. Acoustic Doppler current profiler measurements were used to evaluate bed-sediment velocity. Results indicate varying amounts of deposition, erosion, net change, and sediment transport in the four Lower Missouri River reaches. The Yankton reach was the most stable over monthly and annual time-frames. The Kenslers Bend and Little Sioux reaches exhibited substantial amounts of deposition and erosion, although net change was generally low in both reaches. Total, or gross geomorphic change was greatest in the Kenslers Bend reach. The Miami reach exhibited varying rates of deposition and erosion, and low net change. The Yankton, Kenslers Bend, and Miami reaches experienced net erosion during the time period that bracketed the managed May 2006 spring rise event from Gavins Point Dam.
Kussman, B D; Gruber, E M; Zurakowski, D; Hansen, D D; Sullivan, L J; Laussen, P C
2001-11-01
We evaluated the relationship of the bispectral index (BIS) to commonly used indices of depth of anaesthesia in 19 infants enrolled in a prospective study of the stress response to hypothermic cardiopulmonary bypass. Group 1 (n=8) received high-dose fentanyl by bolus technique; group 2 (n=6) received high-dose fentanyl by continuous infusion; and group 3 (n=5) received a fentanyl-midazolam infusion. Blood pressure (BP), heart rate (HR) and plasma epinephrine, norepinephrine, cortisol, ACTH, glucose, lactate and fentanyl were analysed 15 min postinduction, 15 min poststernotomy, 15 min on CPB during cooling and during skin closure. Mean BIS (SD) values for all 19 patients were 45.3 (12.3), 40.4 (14.5), 24.4 (12.4) and 47.9 (13.9), at the successive time points. No significant differences were observed in changes in BIS over time between the groups. A significant correlation was found 15 min postinduction between BIS and BP (systolic r=0.51, mean r=0.56) in all groups, but not between BIS and HR. BIS did not correlate with BP or HR at any other time point. There was no significant correlation between BIS and hormonal, biochemical or plasma fentanyl levels for any group at any time point. We were unable to demonstrate a relationship between the BIS and haemodynamic, metabolic or hormonal indices of anaesthetic depth. Further evaluation of the BIS algorithm is required in neonates and infants.
Pinkawa, Michael; Piroth, Marc D; Holy, Richard; Klotz, Jens; Djukic, Victoria; Corral, Nuria Escobar; Caffaro, Mariana; Winz, Oliver H; Krohn, Thomas; Mottaghy, Felix M; Eble, Michael J
2012-01-30
In comparison to the conventional whole-prostate dose escalation, an integrated boost to the macroscopic malignant lesion might potentially improve tumor control rates without increasing toxicity. Quality of life after radiotherapy (RT) with vs. without (18)F-choline PET-CT detected simultaneous integrated boost (SIB) was prospectively evaluated in this study. Whole body image acquisition in supine patient position followed 1 h after injection of 178-355MBq (18)F-choline. SIB was defined by a tumor-to-background uptake value ratio > 2 (GTV(PET)). A dose of 76Gy was prescribed to the prostate (PTV(prostate)) in 2Gy fractions, with or without SIB up to 80Gy. Patients treated with (n = 46) vs. without (n = 21) SIB were surveyed prospectively before (A), at the last day of RT (B) and a median time of two (C) and 19 month (D) after RT to compare QoL changes applying a validated questionnaire (EPIC - expanded prostate cancer index composite). With a median cut-off standard uptake value (SUV) of 3, a median GTV(PET) of 4.0 cm(3) and PTV(boost) (GTV(PET) with margins) of 17.3 cm(3) was defined. No significant differences were found for patients treated with vs. without SIB regarding urinary and bowel QoL changes at times B, C and D (mean differences ≤3 points for all comparisons). Significantly decreasing acute urinary and bowel score changes (mean changes > 5 points in comparison to baseline level at time A) were found for patients with and without SIB. However, long-term urinary and bowel QoL (time D) did not differ relative to baseline levels - with mean urinary and bowel function score changes < 3 points in both groups (median changes = 0 points). Only sexual function scores decreased significantly (> 5 points) at time D. Treatment planning with (18)F-choline PET-CT allows a dose escalation to a macroscopic intraprostatic lesion without significantly increasing toxicity.
Taylor, Marcus K; Larson, Gerald E; Hiller Lauby, Melissa D; Padilla, Genieleah A; Wilson, Ingrid E; Schmied, Emily A; Highfill-McRoy, Robyn M; Morgan, Charles A
2014-01-01
Evidence points to heightened physiological arousal in response to acute stress exposure as both a prospective indicator and a core characteristic of posttraumatic stress disorder (PTSD). Because females may be at higher risk for PTSD development, it is important to evaluate sex differences in acute stress reactions. This study characterized sex differences in cardiovascular and subjective stress reactions among military survival trainees. One hundred and eighty-five military members (78% males) were studied before, during, and 24 h after stressful mock captivity. Cardiovascular (heart rate [HR], systolic blood pressure [SBP], diastolic blood pressure [DBP]) and dissociative states were measured at all three time points. Psychological impact of mock captivity was assessed during recovery. General linear modeling with repeated measures evaluated sex differences for each cardiovascular endpoint, and causal steps modeling was used to explore interrelationships among sex, cardiovascular reactions and psychological impact of mock captivity. Although females had lower SBP than males at all three time points, the difference was most pronounced at baseline and during stress. Accordingly, females showed greater residual elevation in SBP during recovery. Females had lower DBP at all three time points. In addition, females reported greater psychological impact of mock captivity than males. Exploratory causal steps modeling suggested that stress-induced HR may partially mediate the effect of sex on psychological impact of mock captivity. In conclusion, this study demonstrated sex-specific cardiovascular stress reactions in military personnel, along with greater psychological impact of stress exposure in females. This research may elucidate sex differences in PTSD development.
Goldfield, Eugene C; Buonomo, Carlo; Fletcher, Kara; Perez, Jennifer; Margetts, Stacey; Hansen, Anne; Smith, Vincent; Ringer, Steven; Richardson, Michael J; Wolff, Peter H
2010-04-01
Coordination between movements of individual tongue points, and between soft palate elevation and tongue movements, were examined in 12 prematurely born infants referred from hospital NICUs for videofluoroscopic swallow study (VFSS) due to poor oral feeding and suspicion of aspiration. Detailed post-evaluation kinematic analysis was conducted by digitizing images of a lateral view of digitally superimposed points on the tongue and soft palate. The primary measure of coordination was continuous relative phase of the time series created by movements of points on the tongue and soft palate over successive frames. Three points on the tongue (anterior, medial, and posterior) were organized around a stable in-phase pattern, with a phase lag that implied an anterior to posterior direction of motion. Coordination between a tongue point and a point on the soft palate during lowering and elevation was close to anti-phase at initiation of the pharyngeal swallow. These findings suggest that anti-phase coordination between tongue and soft palate may reflect the process by which the tongue is timed to pump liquid by moving it into an enclosed space, compressing it, and allowing it to leave by a specific route through the pharynx. Copyright 2009 Elsevier Inc. All rights reserved.
Stream Kriging: Incremental and recursive ordinary Kriging over spatiotemporal data streams
NASA Astrophysics Data System (ADS)
Zhong, Xu; Kealy, Allison; Duckham, Matt
2016-05-01
Ordinary Kriging is widely used for geospatial interpolation and estimation. Due to the O (n3) time complexity of solving the system of linear equations, ordinary Kriging for a large set of source points is computationally intensive. Conducting real-time Kriging interpolation over continuously varying spatiotemporal data streams can therefore be especially challenging. This paper develops and tests two new strategies for improving the performance of an ordinary Kriging interpolator adapted to a stream-processing environment. These strategies rely on the expectation that, over time, source data points will frequently refer to the same spatial locations (for example, where static sensor nodes are generating repeated observations of a dynamic field). First, an incremental strategy improves efficiency in cases where a relatively small proportion of previously processed spatial locations are absent from the source points at any given iteration. Second, a recursive strategy improves efficiency in cases where there is substantial set overlap between the sets of spatial locations of source points at the current and previous iterations. These two strategies are evaluated in terms of their computational efficiency in comparison to ordinary Kriging algorithm. The results show that these two strategies can reduce the time taken to perform the interpolation by up to 90%, and approach average-case time complexity of O (n2) when most but not all source points refer to the same locations over time. By combining the approaches developed in this paper with existing heuristic ordinary Kriging algorithms, the conclusions indicate how further efficiency gains could potentially be accrued. The work ultimately contributes to the development of online ordinary Kriging interpolation algorithms, capable of real-time spatial interpolation with large streaming data sets.
Coping strategies among patients with newly diagnosed amyotrophic lateral sclerosis.
Jakobsson Larsson, Birgitta; Nordin, Karin; Askmark, Håkan; Nygren, Ingela
2014-11-01
To prospectively identify different coping strategies among newly diagnosed amyotrophic lateral sclerosis patients and whether they change over time and to determine whether physical function, psychological well-being, age and gender correlated with the use of different coping strategies. Amyotrophic lateral sclerosis is a fatal disease with impact on both physical function and psychological well-being. Different coping strategies are used to manage symptoms and disease progression, but knowledge about coping in newly diagnosed amyotrophic lateral sclerosis patients is scarce. This was a prospective study with a longitudinal and descriptive design. A total of 33 patients were included and evaluation was made at two time points, one to three months and six months after diagnosis. Patients were asked to complete the Motor Neuron Disease Coping Scale and the Hospital Anxiety and Depression Scale. Physical function was estimated using the revised Amyotrophic Lateral Sclerosis Functional Rating Scale. The most commonly used strategies were support and independence. Avoidance/venting and information seeking were seldom used at both time points. The use of information seeking decreased between the two time points. Men did not differ from women, but patients ≤64 years used positive action more often than older patients. Amyotrophic Lateral Sclerosis Functional Rating Scale was positively correlated with positive action at time point 1, but not at time point 2. Patients' psychological well-being was correlated with the use of different coping strategies. Support and independence were the most used coping strategies, and the use of different strategies changed over time. Psychological well-being was correlated with different coping strategies in newly diagnosed amyotrophic lateral sclerosis patients. The knowledge about coping strategies in early stage of the disease may help the nurses to improve and develop the care and support for these patients. © 2014 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Sutrisno; Widowati; Solikhin
2016-06-01
In this paper, we propose a mathematical model in stochastic dynamic optimization form to determine the optimal strategy for an integrated single product inventory control problem and supplier selection problem where the demand and purchasing cost parameters are random. For each time period, by using the proposed model, we decide the optimal supplier and calculate the optimal product volume purchased from the optimal supplier so that the inventory level will be located at some point as close as possible to the reference point with minimal cost. We use stochastic dynamic programming to solve this problem and give several numerical experiments to evaluate the model. From the results, for each time period, the proposed model was generated the optimal supplier and the inventory level was tracked the reference point well.
Three-dimensional Simulations of Pure Deflagration Models for Thermonuclear Supernovae
NASA Astrophysics Data System (ADS)
Long, Min; Jordan, George C., IV; van Rossum, Daniel R.; Diemer, Benedikt; Graziani, Carlo; Kessler, Richard; Meyer, Bradley; Rich, Paul; Lamb, Don Q.
2014-07-01
We present a systematic study of the pure deflagration model of Type Ia supernovae (SNe Ia) using three-dimensional, high-resolution, full-star hydrodynamical simulations, nucleosynthetic yields calculated using Lagrangian tracer particles, and light curves calculated using radiation transport. We evaluate the simulations by comparing their predicted light curves with many observed SNe Ia using the SALT2 data-driven model and find that the simulations may correspond to under-luminous SNe Iax. We explore the effects of the initial conditions on our results by varying the number of randomly selected ignition points from 63 to 3500, and the radius of the centered sphere they are confined in from 128 to 384 km. We find that the rate of nuclear burning depends on the number of ignition points at early times, the density of ignition points at intermediate times, and the radius of the confining sphere at late times. The results depend primarily on the number of ignition points, but we do not expect this to be the case in general. The simulations with few ignition points release more nuclear energy E nuc, have larger kinetic energies E K, and produce more 56Ni than those with many ignition points, and differ in the distribution of 56Ni, Si, and C/O in the ejecta. For these reasons, the simulations with few ignition points exhibit higher peak B-band absolute magnitudes M B and light curves that rise and decline more quickly; their M B and light curves resemble those of under-luminous SNe Iax, while those for simulations with many ignition points are not.
Kieves, N R; MacKay, C S; Adducci, K; Rao, S; Goh, C; Palmer, R H; Duerr, F M
2015-01-01
To evaluate the influence of shock wave therapy (SWT) on radiographic evidence of bone healing after tibial plateau leveling osteotomy (TPLO). Healthy dogs between two to nine years of age that underwent TPLO were randomly assigned to receive either electro-hydraulic SWT (1,000 shocks) or sham treatment (SHAM). Treatment or SHAM was administered to the osteotomy site immediately postoperatively and two weeks postoperatively. Three blinded radiologists evaluated orthogonal radiographs performed eight weeks postoperatively with both a 5-point and a 10-point bone healing scale. Linear regression analysis was used to compare median healing scores between groups. Forty-two dogs (50 stifles) were included in the statistical analysis. No major complications were observed and all osteotomies healed uneventfully. The median healing scores were significantly higher at eight weeks postoperatively for the SWT group compared to the SHAM group for the 10-point (p <0.0002) and 5-point scoring systems (p <0.0001). Shock wave therapy applied immediately and two weeks postoperatively led to more advanced bone healing at the eight week time point in this study population. The results of this study support the use of electro-hydraulic SWT as a means of accelerating acute bone healing of canine osteotomies. Additional studies are needed to evaluate its use for acceleration of bone healing following fracture, or with delayed union.
Burnstein, Bryan D.; Steele, Russell J.; Shrier, Ian
2011-01-01
Context: Fitness testing is used frequently in many areas of physical activity, but the reliability of these measurements under real-world, practical conditions is unknown. Objective: To evaluate the reliability of specific fitness tests using the methods and time periods used in the context of real-world sport and occupational management. Design: Cohort study. Setting: Eighteen different Cirque du Soleil shows. Patients or Other Participants: Cirque du Soleil physical performers who completed 4 consecutive tests (6-month intervals) and were free of injury or illness at each session (n = 238 of 701 physical performers). Intervention(s): Performers completed 6 fitness tests on each assessment date: dynamic balance, Harvard step test, handgrip, vertical jump, pull-ups, and 60-second jump test. Main Outcome Measure(s): We calculated the intraclass coefficient (ICC) and limits of agreement between baseline and each time point and the ICC over all 4 time points combined. Results: Reliability was acceptable (ICC > 0.6) over an 18-month time period for all pairwise comparisons and all time points together for the handgrip, vertical jump, and pull-up assessments. The Harvard step test and 60-second jump test had poor reliability (ICC < 0.6) between baseline and other time points. When we excluded the baseline data and calculated the ICC for 6-month, 12-month, and 18-month time points, both the Harvard step test and 60-second jump test demonstrated acceptable reliability. Dynamic balance was unreliable in all contexts. Limit-of-agreement analysis demonstrated considerable intraindividual variability for some tests and a learning effect by administrators on others. Conclusions: Five of the 6 tests in this battery had acceptable reliability over an 18-month time frame, but the values for certain individuals may vary considerably from time to time for some tests. Specific tests may require a learning period for administrators. PMID:22488138
Park, C; Choi, J B; Lee, Y-S; Chang, H-S; Shin, C S; Kim, S; Han, D W
2015-04-01
Posterior neck pain following thyroidectomy is common because full neck extension is required during the procedure. We evaluated the effect of intra-operative transcutaneous electrical nerve stimulation on postoperative neck pain in patients undergoing total thyroidectomy under general anaesthesia. One hundred patients were randomly assigned to one of two groups; 50 patients received transcutaneous electrical nerve stimulation applied to the trapezius muscle and 50 patients acted as controls. Postoperative posterior neck pain and anterior wound pain were evaluated using an 11-point numerical rating scale at 30 min, 6 h, 24 h and 48 h following surgery. The numerical rating scale for posterior neck pain was significantly lower in the transcutaneous electrical nerve stimulation group compared with the control group at all time points (p < 0.05). There were no significant differences in the numerical rating scale for anterior wound pain at any time point. No adverse effects related to transcutaneous electrical nerve stimulation were observed. We conclude that intra-operative transcutaneous electrical nerve stimulation applied to the trapezius muscle reduced posterior neck pain following thyroidectomy. © 2014 The Association of Anaesthetists of Great Britain and Ireland.
Spagnoli, A; Foresti, G; MacDonald, A; Williams, P
1987-05-01
The Organic Brain Syndrome (OBS) and the Depression (D) scales derived from the Comprehensive Assessment and Referral Evaluation (CARE) were translated into Italian and used in a survey of geriatric institutions in Milan. During the survey validity and reliability tests of the scales were conducted. Inter-rater reliability (total score weighted kappa) was highly satisfactory for both scales (0.96 for OBS and 0.83 for D scale). Reliability was assessed three times during the survey and showed good stability for both scales, with a slight but significant trend towards reduction over time for the D scale. Reliability of the D scale was significantly lower when the subjects interviewed scored highly on the OBS scale (severe cognitive impairment). Criterion validity was highly satisfactory both for the OBS scale (cut-off point 4/5: sensitivity 77%, specificity 96%, positive predictive value 91%) and the D scale (cut-off point 10/11: sensitivity 95%, specificity 92%, positive predictive value 84%). Results are discussed with special reference to longitudinal assessment of reliability, the choice of the cut-off point, and the context-dependent properties of questionnaires.
Yock, Adam D.; Rao, Arvind; Dong, Lei; Beadle, Beth M.; Garden, Adam S.; Kudchadker, Rajat J.; Court, Laurence E.
2014-01-01
Purpose: To create models that forecast longitudinal trends in changing tumor morphology and to evaluate and compare their predictive potential throughout the course of radiation therapy. Methods: Two morphology feature vectors were used to describe 35 gross tumor volumes (GTVs) throughout the course of intensity-modulated radiation therapy for oropharyngeal tumors. The feature vectors comprised the coordinates of the GTV centroids and a description of GTV shape using either interlandmark distances or a spherical harmonic decomposition of these distances. The change in the morphology feature vector observed at 33 time points throughout the course of treatment was described using static, linear, and mean models. Models were adjusted at 0, 1, 2, 3, or 5 different time points (adjustment points) to improve prediction accuracy. The potential of these models to forecast GTV morphology was evaluated using leave-one-out cross-validation, and the accuracy of the models was compared using Wilcoxon signed-rank tests. Results: Adding a single adjustment point to the static model without any adjustment points decreased the median error in forecasting the position of GTV surface landmarks by the largest amount (1.2 mm). Additional adjustment points further decreased the forecast error by about 0.4 mm each. Selection of the linear model decreased the forecast error for both the distance-based and spherical harmonic morphology descriptors (0.2 mm), while the mean model decreased the forecast error for the distance-based descriptor only (0.2 mm). The magnitude and statistical significance of these improvements decreased with each additional adjustment point, and the effect from model selection was not as large as that from adding the initial points. Conclusions: The authors present models that anticipate longitudinal changes in tumor morphology using various models and model adjustment schemes. The accuracy of these models depended on their form, and the utility of these models includes the characterization of patient-specific response with implications for treatment management and research study design. PMID:25086518
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yock, Adam D.; Kudchadker, Rajat J.; Rao, Arvind
2014-08-15
Purpose: To create models that forecast longitudinal trends in changing tumor morphology and to evaluate and compare their predictive potential throughout the course of radiation therapy. Methods: Two morphology feature vectors were used to describe 35 gross tumor volumes (GTVs) throughout the course of intensity-modulated radiation therapy for oropharyngeal tumors. The feature vectors comprised the coordinates of the GTV centroids and a description of GTV shape using either interlandmark distances or a spherical harmonic decomposition of these distances. The change in the morphology feature vector observed at 33 time points throughout the course of treatment was described using static, linear,more » and mean models. Models were adjusted at 0, 1, 2, 3, or 5 different time points (adjustment points) to improve prediction accuracy. The potential of these models to forecast GTV morphology was evaluated using leave-one-out cross-validation, and the accuracy of the models was compared using Wilcoxon signed-rank tests. Results: Adding a single adjustment point to the static model without any adjustment points decreased the median error in forecasting the position of GTV surface landmarks by the largest amount (1.2 mm). Additional adjustment points further decreased the forecast error by about 0.4 mm each. Selection of the linear model decreased the forecast error for both the distance-based and spherical harmonic morphology descriptors (0.2 mm), while the mean model decreased the forecast error for the distance-based descriptor only (0.2 mm). The magnitude and statistical significance of these improvements decreased with each additional adjustment point, and the effect from model selection was not as large as that from adding the initial points. Conclusions: The authors present models that anticipate longitudinal changes in tumor morphology using various models and model adjustment schemes. The accuracy of these models depended on their form, and the utility of these models includes the characterization of patient-specific response with implications for treatment management and research study design.« less
Lichtveld, Maureen Y.; Shankar, Arti; Mundorf, Chris; Hassan, Anna; Drury, Stacy
2016-01-01
The Scale to Assess the Therapeutic Relationship in Community Mental Health Care (STAR) is a frequently-administered tool for measuring therapeutic relationships between clinicians and patients. This manuscript tested the STAR’s psychometric properties within a community health worker (CHW)-led intervention study involving pregnant and postpartum women. Women (n = 141) enrolled in the study completed the 12-item participant STAR survey (STAR-P) at two time points over the course of pregnancy and at two time points after delivery. The factor structure of the STAR-P proved to be unstable with this population. However, a revised 9-item STAR-P revealed a two-factor model of positive and negative interactions, and demonstrated strong internal consistency at postpartum time points. The revised STAR-P shows strong psychometric properties, and is suitable for use to evaluate the relationship developed between CHWs and pregnant and postpartum women in an intervention program. PMID:27116361
Lichtveld, Maureen Y; Shankar, Arti; Mundorf, Chris; Hassan, Anna; Drury, Stacy
2016-12-01
The Scale to Assess the Therapeutic Relationship in Community Mental Health Care (STAR) is a frequently-administered tool for measuring therapeutic relationships between clinicians and patients. This manuscript tested the STAR's psychometric properties within a community health worker (CHW)-led intervention study involving pregnant and postpartum women. Women (n = 141) enrolled in the study completed the 12-item participant STAR survey (STAR-P) at two time points over the course of pregnancy and at two time points after delivery. The factor structure of the STAR-P proved to be unstable with this population. However, a revised 9-item STAR-P revealed a two-factor model of positive and negative interactions, and demonstrated strong internal consistency at postpartum time points. The revised STAR-P shows strong psychometric properties, and is suitable for use to evaluate the relationship developed between CHWs and pregnant and postpartum women in an intervention program.
Longitudinal Effects on Early Adolescent Language: A Twin Study
DeThorne, Laura Segebart; Smith, Jamie Mahurin; Betancourt, Mariana Aparicio; Petrill, Stephen A.
2016-01-01
Purpose We evaluated genetic and environmental contributions to individual differences in language skills during early adolescence, measured by both language sampling and standardized tests, and examined the extent to which these genetic and environmental effects are stable across time. Method We used structural equation modeling on latent factors to estimate additive genetic, shared environmental, and nonshared environmental effects on variance in standardized language skills (i.e., Formal Language) and productive language-sample measures (i.e., Productive Language) in a sample of 527 twins across 3 time points (mean ages 10–12 years). Results Individual differences in the Formal Language factor were influenced primarily by genetic factors at each age, whereas individual differences in the Productive Language factor were primarily due to nonshared environmental influences. For the Formal Language factor, the stability of genetic effects was high across all 3 time points. For the Productive Language factor, nonshared environmental effects showed low but statistically significant stability across adjacent time points. Conclusions The etiology of language outcomes may differ substantially depending on assessment context. In addition, the potential mechanisms for nonshared environmental influences on language development warrant further investigation. PMID:27732720
Gill, Thomas M; Han, Ling; Gahbauer, Evelyne A; Leo-Summers, Linda; Allore, Heather G
2018-05-02
To evaluate the prognostic effect of changes in physical function at different intervals over the prior year on subsequent outcomes after accounting for present function. Prospective longitudinal study. Greater New Haven, Connecticut, from March 1998 to January 2006. Community-living persons aged 71 and older who completed an 18-month comprehensive assessment (N=658). Disability in 13 activities of daily living, instrumental activities of daily living, and mobility activities was assessed at the 18-month comprehensive assessment and at 12, 6, and 3 months before 18 months. Time to death and long-term nursing home admission, defined as 3 months and longer, were ascertained for up to 5 years after 18 months. In the bivariate models, disability at 18 months and change in disability between 18 months and each of the 3 prior time-points (12, 6, 3 months) were significantly associated with time to death. The risk of death, for example, increased by 24% for each 1-point increase in 18-month disability score (on a scale from 0 to 13) and by 22% for each 1-point change in disability score between 18 months and prior 12 months (on a scale from -13 to 13). In a set of multivariable models with and without covariates, the associations were maintained for 18-month disability but not for change in disability between 18 months and each of the 3 prior time-points. The results were comparable for time to long-term nursing home admission except that 2 of the associations were not statistically significant. When evaluating risk of adverse outcomes, such as death and long-term nursing home admission, an assessment of change in physical function at different intervals over the prior year, although a strong bivariate predictor, did not provide useful prognostic information beyond that available from current level of function. © 2018, Copyright the Authors Journal compilation © 2018, The American Geriatrics Society.
Acute Toxicity Evaluation of Nitroaromatic Compounds
1991-03-01
eye of any animal during the observation period. Extreme fluorescein staining was evident in all of the test animals. Pannus (corneal vasculation) was...treated eyes at this time point showed signs of pannus . 39 0 TABLE 13 ACUTE ORAL - RANGE FINDING - RATS 1,3,5-TRINITROBENZENE Dose Dose Wt (g) Wt (g) Wt...the cornea at the 24h, 48h, 72h and 96h observation points. Additional Observations: Pannus (corneal vascularization) was noted at the 96h observation
NASA Technical Reports Server (NTRS)
Pedretti, Kevin T.; Fineberg, Samuel A.; Kutler, Paul (Technical Monitor)
1997-01-01
A variety of different network technologies and topologies are currently being evaluated as part of the Whitney Project. This paper reports on the implementation and performance of a Fast Ethernet network configured in a 4x4 2D torus topology in a testbed cluster of 'commodity' Pentium Pro PCs. Several benchmarks were used for performance evaluation: an MPI point to point message passing benchmark, an MPI collective communication benchmark, and the NAS Parallel Benchmarks version 2.2 (NPB2). Our results show that for point to point communication on an unloaded network, the hub and 1 hop routes on the torus have about the same bandwidth and latency. However, the bandwidth decreases and the latency increases on the torus for each additional route hop. Collective communication benchmarks show that the torus provides roughly four times more aggregate bandwidth and eight times faster MPI barrier synchronizations than a hub based network for 16 processor systems. Finally, the SOAPBOX benchmarks, which simulate real-world CFD applications, generally demonstrated substantially better performance on the torus than on the hub. In the few cases the hub was faster, the difference was negligible. In total, our experimental results lead to the conclusion that for Fast Ethernet networks, the torus topology has better performance and scales better than a hub based network.
Evaluating the ability of regional models to predict local avian abundance
LeBrun, Jaymi J.; Thogmartin, Wayne E.; Miller, James R.
2012-01-01
Spatial modeling over broad scales can potentially direct conservation efforts to areas with high species-specific abundances. We examined the performance of regional models for predicting bird abundance at spatial scales typically addressed in conservation planning. Specifically, we used point count data on wood thrush (Hylocichla mustelina) and blue-winged warbler (Vermivora cyanoptera) from 2 time periods (1995-1998 and 2006-2007) to evaluate the ability of regional models derived via Bayesian hierarchical techniques to predict bird abundance. We developed models for each species within Bird Conservation Region (BCR) 23 in the upper midwestern United States at 800-ha, 8,000-ha, and approximately 80,000-ha scales. We obtained count data from the Breeding Bird Survey and land cover data from the National Land Cover Dataset (1992). We evaluated predictions from the best models, as defined by an information-theoretic criterion, using point count data collected within an ecological subregion of BCR 23 at 131 count stations in the 1990s and again in 2006-2007. Competing (Deviance Information Criteria rs = 0.57; P = 0.14), the survey period that most closely aligned with the time period of data used for regional model construction. Wood thrush models exhibited positive correlations with point count data for all survey areas and years combined (rs = 0.58, P ≤ 0.001). In comparison, blue-winged warbler models performed worse as time increased between the point count surveys and vintage of the model building data (rs = 0.03, P = 0.92 for Iowa and rs = 0.13, P = 0.51 for all areas, 2006-2007), likely related to the ephemeral nature of their preferred early successional habitat. Species abundance and sensitivity to changing habitat conditions seems to be an important factor in determining the predictive ability of regional models. Hierarchical models can be a useful tool for concentrating efforts at the scale of management units and should be one of many tools used by land managers, but we caution that the utility of such models may decrease over time for species preferring relatively ephemeral habitats if model inputs are not updated accordingly.
Performance Evaluation of Remote Memory Access (RMA) Programming on Shared Memory Parallel Computers
NASA Technical Reports Server (NTRS)
Jin, Hao-Qiang; Jost, Gabriele; Biegel, Bryan A. (Technical Monitor)
2002-01-01
The purpose of this study is to evaluate the feasibility of remote memory access (RMA) programming on shared memory parallel computers. We discuss different RMA based implementations of selected CFD application benchmark kernels and compare them to corresponding message passing based codes. For the message-passing implementation we use MPI point-to-point and global communication routines. For the RMA based approach we consider two different libraries supporting this programming model. One is a shared memory parallelization library (SMPlib) developed at NASA Ames, the other is the MPI-2 extensions to the MPI Standard. We give timing comparisons for the different implementation strategies and discuss the performance.
NASA Astrophysics Data System (ADS)
Vu, Tinh Thi; Kiesel, Jens; Guse, Bjoern; Fohrer, Nicola
2017-04-01
The damming of rivers causes one of the most considerable impacts of our society on the riverine environment. More than 50% of the world's streams and rivers are currently impounded by dams before reaching the oceans. The construction of dams is of high importance in developing and emerging countries, i.e. for power generation and water storage. In the Vietnamese Vu Gia - Thu Bon Catchment (10,350 km2), about 23 dams were built during the last decades and store approximately 2,156 billion m3 of water. The water impoundment in 10 dams in upstream regions amounts to 17 % of the annual discharge volume. It is expected that impacts from these dams have altered the natural flow regime. However, up to now it is unclear how the flow regime was altered. For this, it needs to be investigated at what point in time these changes became significant and detectable. Many approaches exist to detect changes in stationary or consistency of hydrological records using statistical analysis of time series for the pre- and post-dam period. The objective of this study is to reliably detect and assess hydrologic shifts occurring in the discharge regime of an anthropogenically influenced river basin, mainly affected by the construction of dams. To achieve this, we applied nine available change-point tests to detect change in mean, variance and median on the daily and annual discharge records at two main gauges of the basin. The tests yield conflicting results: The majority of tests found abrupt changes that coincide with the damming-period, while others did not. To interpret how significant the changes in discharge regime are, and to which different properties of the time series each test responded, we calculated Indicators of Hydrologic Alteration (IHAs) for the time period before and after the detected change points. From the results, we can deduce, that the change point tests are influenced in different levels by different indicator groups (magnitude, duration, frequency, etc) and that within the indicator groups, some indicators are more sensitive than others. For instance, extreme low-flow, especially 7- and, 30-day minima and mean minimum low flow, as well as the variability of monthly flow are highly-sensitive to most detected change points. Our study clearly shows that, the detected change points depend on which test is chosen. For an objective assessment of change points, it is therefore necessary to explain the change points by calculating differences in IHAs. This analysis can be used to assess which change point method reacts to which type of hydrological change and, more importantly, it can be used to rank the change points according to their overall impact on the discharge regime. This leads to an improved evaluation of hydrologic change-points caused by anthropogenic impacts. Our study clearly shows that, the detected change points depend on which test is chosen. For an objective assessment of change points, it is therefore necessary to explain the change points by calculating differences in IHAs. This analysis can be used to assess which change point method reacts to which type of hydrological change and, more importantly, it can be used to rank the change points according to their overall impact on the discharge regime. This leads to an improved evaluation of hydrologic change-points caused by anthropogenic impacts.
1979-12-01
processing holding register upset times. Therefore reaction wh these transient response times will not significantly affect pointing of SS7 -20 a error...change so that the requirements of SS7 -20 are not met. Command Logic and Power Switching I Transients whall not cause mode changes to occur in the CEA
Evaluation of EEG based determination of unconsciousness vs. loss of posture in broilers.
Benson, E R; Alphin, R L; Rankin, M K; Caputo, M P; Kinney, C A; Johnson, A L
2012-10-01
Evaluation of the loss of consciousness in poultry is an essential component in evaluating bird welfare under a variety of situations and applications. Many current approaches to evaluating loss of consciousness are qualitative and require observation of the bird. This study outlines a quantitative method for determining the point at which a bird loses consciousness. In this study, commercial broilers were individually anesthetized and the brain activity recorded as the bird became unconscious. A wireless EEG transmitter was surgically implanted and the bird anesthetized after a 24-48 h recovery. Each bird was monitored during treatment with isoflurane anesthesia and EEG data was evaluated using a frequency based approach. The alpha/delta (A/D) ratio and loss of posture (LOP) were used to determine the point at which the birds went unconscious. There was no statistically significant difference between time to unconsciousness as measured by A/D ratio or LOP. Copyright © 2011 Elsevier Ltd. All rights reserved.
Determination of the Persistence of Non-Spore-Forming ...
Report This report presents the results of an investigation to evaluate the persistence (or natural attenuation) of Yersinia pestis (Y. pestis), Francisella tularensis (F. tularensis), and Burkholderia mallei (B. mallei) on glass and soil under multiple environmental conditions and time points.
On the tip of the tongue: learning typing and pointing with an intra-oral computer interface.
Caltenco, Héctor A; Breidegard, Björn; Struijk, Lotte N S Andreasen
2014-07-01
To evaluate typing and pointing performance and improvement over time of four able-bodied participants using an intra-oral tongue-computer interface for computer control. A physically disabled individual may lack the ability to efficiently control standard computer input devices. There have been several efforts to produce and evaluate interfaces that provide individuals with physical disabilities the possibility to control personal computers. Training with the intra-oral tongue-computer interface was performed by playing games over 18 sessions. Skill improvement was measured through typing and pointing exercises at the end of each training session. Typing throughput improved from averages of 2.36 to 5.43 correct words per minute. Pointing throughput improved from averages of 0.47 to 0.85 bits/s. Target tracking performance, measured as relative time on target, improved from averages of 36% to 47%. Path following throughput improved from averages of 0.31 to 0.83 bits/s and decreased to 0.53 bits/s with more difficult tasks. Learning curves support the notion that the tongue can rapidly learn novel motor tasks. Typing and pointing performance of the tongue-computer interface is comparable to performances of other proficient assistive devices, which makes the tongue a feasible input organ for computer control. Intra-oral computer interfaces could provide individuals with severe upper-limb mobility impairments the opportunity to control computers and automatic equipment. Typing and pointing performance of the tongue-computer interface is comparable to performances of other proficient assistive devices, but does not cause fatigue easily and might be invisible to other people, which is highly prioritized by assistive device users. Combination of visual and auditory feedback is vital for a good performance of an intra-oral computer interface and helps to reduce involuntary or erroneous activations.
ACTS Multibeam Antenna On-Orbit Performance
NASA Technical Reports Server (NTRS)
Acosta, R.; Wright, D.; Mitchell, Kenneth
1996-01-01
The Advanced Communications Technology Satellite (ACTS) launched in September 1993 introduces several new technologies including a multibeam antenna (MBA) operating at Ka-band. The MBA with fixed and rapidly reconfigurable spot beams serves users equipped with small aperture terminals within the coverage area. The antenna produces spot beams with approximately 0.3 degrees beamwidth and gains of approximately 50 dBi. A number of MBA performance evaluations have been performed since the ACTS launch. These evaluations were designed to assess MBA performance (e.g., beam pointing stability, beam shape, gain, etc.) in the space environment. The on-orbit measurements found systematic environmental perturbation to the MBA beam pointing. These perturbations were found to be imposed by satellite attitude control system, antenna and spacecraft mechanical alignments, on-orbit thermal effects, etc. As a result, the footprint coverage of the MBA may not exactly cover the intended service area at all times. This report describes the space environment effects on the ACTS MBA performance as a function of time of the day and time of the year and compensation approaches for these effects.
Haque, Muhammad E; Franklin, Tammy; Bokhary, Ujala; Mathew, Liby; Hack, Bradley K; Chang, Anthony; Puri, Tipu S; Prasad, Pottumarthi V
2014-04-01
To evaluate longitudinal changes in renal oxygenation and diffusion measurements in a model of reversible unilateral ureteral obstruction (rUUO) which has been shown to induce chronic renal functional deficits in a strain dependent way. C57BL/6 mice show higher degree of functional deficit compared with BALB/c mice. Because hypoxia and development of fibrosis are associated with chronic kidney diseases and are responsible for progression, we hypothesized that MRI measurements would be able to monitor the longitudinal changes in this model and will show strain dependent differences in response. Here blood oxygenation level dependent (BOLD) and diffusion MRI measurements were performed at three time points over a 30 day period in mice with rUUO. The studies were performed on a 4.7T scanner with the mice anesthetized with isoflurane before UUO, 2 and 28 days postrelease of 6 days of obstruction. We found at the early time point (∼2 days after releasing the obstruction), the relative oxygenation in C57Bl/6 mice were lower compared with BALB/c. Diffusion measurements were lower at this time point and reached statistical significance in BALB/c These methods may prove valuable in better understanding the natural progression of kidney diseases and in evaluating novel interventions to limit progression. Copyright © 2013 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Tang, Guoqiang; Behrangi, Ali; Long, Di; Li, Changming; Hong, Yang
2018-04-01
Rain gauge observations are commonly used to evaluate the quality of satellite precipitation products. However, the inherent difference between point-scale gauge measurements and areal satellite precipitation, i.e. a point of space in time accumulation v.s. a snapshot of time in space aggregation, has an important effect on the accuracy and precision of qualitative and quantitative evaluation results. This study aims to quantify the uncertainty caused by various combinations of spatiotemporal scales (0.1°-0.8° and 1-24 h) of gauge network designs in the densely gauged and relatively flat Ganjiang River basin, South China, in order to evaluate the state-of-the-art satellite precipitation, the Integrated Multi-satellite Retrievals for Global Precipitation Measurement (IMERG). For comparison with the dense gauge network serving as "ground truth", 500 sparse gauge networks are generated through random combinations of gauge numbers at each set of spatiotemporal scales. Results show that all sparse gauge networks persistently underestimate the performance of IMERG according to most metrics. However, the probability of detection is overestimated because hit and miss events are more likely fewer than the reference numbers derived from dense gauge networks. A nonlinear error function of spatiotemporal scales and the number of gauges in each grid pixel is developed to estimate the errors of using gauges to evaluate satellite precipitation. Coefficients of determination of the fitting are above 0.9 for most metrics. The error function can also be used to estimate the required minimum number of gauges in each grid pixel to meet a predefined error level. This study suggests that the actual quality of satellite precipitation products could be better than conventionally evaluated or expected, and hopefully enables non-subject-matter-expert researchers to have better understanding of the explicit uncertainties when using point-scale gauge observations to evaluate areal products.
Point-of-Care Ultrasonography for Evaluation of Acute Dyspnea in the ED.
Zanobetti, Maurizio; Scorpiniti, Margherita; Gigli, Chiara; Nazerian, Peiman; Vanni, Simone; Innocenti, Francesca; Stefanone, Valerio T; Savinelli, Caterina; Coppa, Alessandro; Bigiarini, Sofia; Caldi, Francesca; Tassinari, Irene; Conti, Alberto; Grifoni, Stefano; Pini, Riccardo
2017-06-01
Acute dyspnea is a common symptom in the ED. The standard approach to dyspnea often relies on radiologic and laboratory results, causing excessive delay before adequate therapy is started. Use of an integrated point-of-care ultrasonography (PoCUS) approach can shorten the time needed to formulate a diagnosis, while maintaining an acceptable safety profile. Consecutive adult patients presenting with dyspnea and admitted after ED evaluation were prospectively enrolled. The gold standard was the final diagnosis assessed by two expert reviewers. Two physicians independently evaluated the patient; a sonographer performed an ultrasound evaluation of the lung, heart, and inferior vena cava, while the treating physician requested traditional tests as needed. Time needed to formulate the ultrasound and the ED diagnoses was recorded and compared. Accuracy and concordance of the ultrasound and the ED diagnoses were calculated. A total of 2,683 patients were enrolled. The average time needed to formulate the ultrasound diagnosis was significantly lower than that required for ED diagnosis (24 ± 10 min vs 186 ± 72 min; P = .025). The ultrasound and the ED diagnoses showed good overall concordance (κ = 0.71). There were no statistically significant differences in the accuracy of PoCUS and the standard ED evaluation for the diagnosis of acute coronary syndrome, pneumonia, pleural effusion, pericardial effusion, pneumothorax, and dyspnea from other causes. PoCUS was significantly more sensitive for the diagnosis of heart failure, whereas a standard ED evaluation performed better in the diagnosis of COPD/asthma and pulmonary embolism. PoCUS represents a feasible and reliable diagnostic approach to the patient with dyspnea, allowing a reduction in time to diagnosis. This protocol could help to stratify patients who should undergo a more detailed evaluation. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Interpretation of human pointing by African elephants: generalisation and rationality.
Smet, Anna F; Byrne, Richard W
2014-11-01
Factors influencing the abilities of different animals to use cooperative social cues from humans are still unclear, in spite of long-standing interest in the topic. One of the few species that have been found successful at using human pointing is the African elephant (Loxodonta africana); despite few opportunities for learning about pointing, elephants follow a pointing gesture in an object-choice task, even when the pointing signal and experimenter's body position are in conflict, and when the gesture itself is visually subtle. Here, we show that the success of captive African elephants at using human pointing is not restricted to situations where the pointing signal is sustained until the time of choice: elephants followed human pointing even when the pointing gesture was withdrawn before they had responded to it. Furthermore, elephants rapidly generalised their response to a type of social cue they were unlikely to have seen before: pointing with the foot. However, unlike young children, they showed no sign of evaluating the 'rationality' of this novel pointing gesture according to its visual context: that is, whether the experimenter's hands were occupied or not.
Initial evaluation of a real-world Internet smoking cessation system
Cobb, Nathan K.; Graham, Amanda L.; Bock, Beth C.; Papandonatos, George; Abrams, David B.
2010-01-01
To significantly reduce smoking prevalence, treatments must balance reach, efficacy, and cost. The Internet can reach millions of smokers cost-effectively. Many cessation Web sites exist, but few have been evaluated. As a result, the potential impact of the Internet on smoking prevalence remains unknown. The present study reports the results, challenges, and limitations of a preliminary, large-scale evaluation of a broadly disseminated smoking cessation Web site used worldwide (QuitNet). Consecutive registrants (N=1,501) were surveyed 3 months after they registered on the Web site to assess 7-day point prevalence abstinence. Results must be interpreted cautiously because this is an uncontrolled study with a 25.6% response rate. Approximately 30% of those surveyed indicated they had already quit smoking at registration. Excluding these participants, an intention-to-treat analysis yielded 7% point prevalence abstinence (for the responders only, abstinence was 30%). A range of plausible cessation outcomes (9.8%–13.1%) among various subgroups is presented to illustrate the strengths and limitations of conducting Web-based evaluations, and the tensions between clinical and dissemination research methods. Process-to-outcome analyses indicated that sustained use of QuitNet, especially the use of social support, was associated with more than three times greater point prevalence abstinence and more than four times greater continuous abstinence. Despite its limitations, the present study provides useful information about the potential efficacy, challenging design and methodological issues, process-to-outcome mechanisms of action, and potential public health impact of Internet-based behavior change programs for smoking cessation. PMID:16036277
Ren, Jinma
2016-01-01
Background With advances in mobile technology, accessibility of clinical resources at the point of care has increased. Objective The objective of this research was to identify if six selected mobile point-of-care tools meet the needs of clinicians in internal medicine. Point-of-care tools were evaluated for breadth of coverage, ease of use, and quality. Methods Six point-of-care tools were evaluated utilizing four different devices (two smartphones and two tablets). Breadth of coverage was measured using select International Classification of Diseases, Ninth Revision, codes if information on summary, etiology, pathophysiology, clinical manifestations, diagnosis, treatment, and prognosis was provided. Quality measures included treatment and diagnostic inline references and individual and application time stamping. Ease of use covered search within topic, table of contents, scrolling, affordance, connectivity, and personal accounts. Analysis of variance based on the rank of score was used. Results Breadth of coverage was similar among Medscape (mean 6.88), Uptodate (mean 6.51), DynaMedPlus (mean 6.46), and EvidencePlus (mean 6.41) (P>.05) with DynaMed (mean 5.53) and Epocrates (mean 6.12) scoring significantly lower (P<.05). Ease of use had DynaMedPlus with the highest score, and EvidencePlus was lowest (6.0 vs 4.0, respectively, P<.05). For quality, reviewers rated the same score (4.00) for all tools except for Medscape, which was rated lower (P<.05). Conclusions For breadth of coverage, most point-of-care tools were similar with the exception of DynaMed. For ease of use, only UpToDate and DynaMedPlus allow for search within a topic. All point-of-care tools have remote access with the exception of UpToDate and Essential Evidence Plus. All tools except Medscape covered criteria for quality evaluation. Overall, there was no significant difference between the point-of-care tools with regard to coverage on common topics used by internal medicine clinicians. Selection of point-of-care tools is highly dependent on individual preference based on ease of use and cost of the application. PMID:27733328
Non-invasive evaluation of stable renal allograft function using point shear-wave elastography.
Kim, Bom Jun; Kim, Chan Kyo; Park, Jung Jae
2018-01-01
To investigate the feasibility of point shear-wave elastography (SWE) in evaluating patients with stable renal allograft function who underwent protocol biopsies. 95 patients with stable renal allograft function that underwent ultrasound-guided biopsies at predefined time points (10 days or 1 year after transplantation) were enrolled. Ultrasound and point SWE examinations were performed immediately before protocol biopsies. Patients were categorized into two groups: subclinical rejection (SCR) and non-SCR. Tissue elasticity (kPa) on SWE was measured in the cortex of all renal allografts. SCR was pathologically confirmed in 34 patients. Tissue elasticity of the SCR group (31.0 kPa) was significantly greater than that of the non-SCR group (24.5 kPa) (=0.016), while resistive index value did not show a significant difference between the two groups (p = 0.112). Tissue elasticity in renal allografts demonstrated significantly moderate negative correlation with estimated glomerular filtration rate (correlation coefficient = -0.604, p < 0.001). Tissue elasticity was not independent factor for SCR prediction on multivariate analysis. As a non-invasive tool, point SWE appears feasible in distinguishing between patients with SCR and without SCR in stable functioning renal allografts. Moreover, it may demonstrate the functional state of renal allografts. Advances in knowledge: On point SWE, SCR has greater tissue elasticity than non-SCR.
Statistical characterization of spatial patterns of rainfall cells in extratropical cyclones
NASA Astrophysics Data System (ADS)
Bacchi, Baldassare; Ranzi, Roberto; Borga, Marco
1996-11-01
The assumption of a particular type of distribution of rainfall cells in space is needed for the formulation of several space-time rainfall models. In this study, weather radar-derived rain rate maps are employed to evaluate different types of spatial organization of rainfall cells in storms through the use of distance functions and second-moment measures. In particular the spatial point patterns of the local maxima of rainfall intensity are compared to a completely spatially random (CSR) point process by applying an objective distance measure. For all the analyzed radar maps the CSR assumption is rejected, indicating that at the resolution of the observation considered, rainfall cells are clustered. Therefore a theoretical framework for evaluating and fitting alternative models to the CSR is needed. This paper shows how the "reduced second-moment measure" of the point pattern can be employed to estimate the parameters of a Neyman-Scott model and to evaluate the degree of adequacy to the experimental data. Some limitations of this theoretical framework, and also its effectiveness, in comparison to the use of scaling functions, are discussed.
Measurement of Dam Deformations: Case Study of Obruk Dam (Turkey)
NASA Astrophysics Data System (ADS)
Gulal, V. Engin; Alkan, R. Metin; Alkan, M. Nurullah; İlci, Veli; Ozulu, I. Murat; Tombus, F. Engin; Kose, Zafer; Aladogan, Kayhan; Sahin, Murat; Yavasoglu, Hakan; Oku, Guldane
2016-04-01
In the literature, there is information regarding the first deformation and displacement measurements in dams that were conducted in 1920s Switzerland. Todays, deformation measurements in the dams have gained very different functions with improvements in both measurement equipment and evaluation of measurements. Deformation measurements and analysis are among the main topics studied by scientists who take interest in the engineering measurement sciences. The Working group of Deformation Measurements and Analysis, which was established under the International Federation of Surveyors (FIG), carries out its studies and activities with regard to this subject. At the end of the 1970s, the subject of the determination of fixed points in the deformation monitoring network was one of the main subjects extensively studied. Many theories arose from this inquiry, as different institutes came to differing conclusions. In 1978, a special commission with representatives of universities has been established within the FIG 6.1 working group; this commission worked on the issue of determining a general approach to geometric deformation analysis. The results gleaned from the commission were discussed at symposiums organized by the FIG. In accordance with these studies, scientists interested in the subject have begun to work on models that investigate cause and effect relations between the effects that cause deformation and deformation. As of the scientist who interest with the issue focused on different deformation methods, another special commission was established within the FIG engineering measurements commission in order to classify deformation models and study terminology. After studying this material for a long time, the official commission report was published in 2001. In this prepared report, studies have been carried out by considering the FIG Engineering Surveying Commission's report entitled, 'MODELS AND TERMINOLOGY FOR THE ANALYSIS OF GEODETIC MONITORING OBSERVATIONS'. In October of 2015, geodetic deformation measurements were conducted by considering FIG reports related to deformation measurements and German DIN 18710 Engineering Measurements norms in the Çorum province of Turkey. The main purpose of the study is to determine optimum measurement and evaluation methods that will be used to specify movements in the horizontal and vertical directions for the fill dam. For this purpose; • In reference networks consisting of 8 points, measurements were performed by using long-term dual-frequency GNSS receivers for duration of 8 hours. • GNSS measurements were conducted in varying times between 30 minutes and 120 minutes at the 44 units object points on the body of the dam. • Two repetitive measurements of real time kinematic (RTK) GNSS were conducted at the object points on dam. • Geometric leveling measurements were performed between reference and object points. • Trigonometric leveling measurements were performed between reference and object points. • Polar measurements were performed between references and object points. GNSS measurements performed at reference points of the monitoring network for 8 hours have been evaluated by using GAMIT software in accordance with the IGS points in the region. In this manner, regional and local movements in the network can be determined. It is aimed to determine measurement period which will provide 1-2mm accuracy that expected in local GNSS network by evaluating GNSS measurements performed on body of dam. Results will be compared by offsetting GNSS and terrestrial measurements. This study will investigate whether or not there is increased accuracy provided by GNSS measurements carried out among reference points without the possibility of vision.
The duration perception of loading applications in smartphone: Effects of different loading types.
Zhao, Wenguo; Ge, Yan; Qu, Weina; Zhang, Kan; Sun, Xianghong
2017-11-01
The loading time of a smartphone application is an important issue, which affects the satisfaction of phone users. This study evaluated the effects of black loading screen (BLS) and animation loading screen (ALS) during application loading on users' duration perception and satisfaction. A total of 43 volunteers were enrolled. They were asked to complete several tasks by clicking the icons of each application, such as camera or message. The duration of loading time for each application was manipulated. The participants were asked to estimate the duration, evaluate the loading speed and their satisfaction. The results showed that the estimated duration increased and the satisfaction for loading period declined along with the loading time increased. Compared with the BLS, the ALS prolonged the estimated duration, and lowered the evaluation of speed and satisfaction. We also discussed the tendency and key inflection points of the curves involving the estimated duration, speed evaluation and satisfaction with the loading time. Copyright © 2017 Elsevier Ltd. All rights reserved.
Joint classification and contour extraction of large 3D point clouds
NASA Astrophysics Data System (ADS)
Hackel, Timo; Wegner, Jan D.; Schindler, Konrad
2017-08-01
We present an effective and efficient method for point-wise semantic classification and extraction of object contours of large-scale 3D point clouds. What makes point cloud interpretation challenging is the sheer size of several millions of points per scan and the non-grid, sparse, and uneven distribution of points. Standard image processing tools like texture filters, for example, cannot handle such data efficiently, which calls for dedicated point cloud labeling methods. It turns out that one of the major drivers for efficient computation and handling of strong variations in point density, is a careful formulation of per-point neighborhoods at multiple scales. This allows, both, to define an expressive feature set and to extract topologically meaningful object contours. Semantic classification and contour extraction are interlaced problems. Point-wise semantic classification enables extracting a meaningful candidate set of contour points while contours help generating a rich feature representation that benefits point-wise classification. These methods are tailored to have fast run time and small memory footprint for processing large-scale, unstructured, and inhomogeneous point clouds, while still achieving high classification accuracy. We evaluate our methods on the semantic3d.net benchmark for terrestrial laser scans with >109 points.
Canty, David J; Heiberg, Johan; Tan, Jen A; Yang, Yang; Royse, Alistair G; Royse, Colin F; Mobeirek, Abdulelah; Shaer, Fayez El; Albacker, Turki; Nazer, Rakan I; Fouda, Muhammed; Bakir, Bakir M; Alsaddique, Ahmed A
2017-06-01
The use of limited transthoracic echocardiography (TTE) has been restricted in patients after cardiac surgery due to reported poor image quality. The authors hypothesized that the hemodynamic state could be evaluated in a high proportion of patients at repeated intervals after cardiac surgery. Prospective observational study. Tertiary university hospital. The study comprised 51 patients aged 18 years or older presenting for cardiac surgery. Patients underwent TTE before surgery and at 3 time points after cardiac surgery. Images were assessed offline using an image quality scoring system by 2 expert observers. Hemodynamic state was assessed using the iHeartScan protocol, and the primary endpoint was the proportion of limited TTE studies in which the hemodynamic state was interpretable at each of the 3 postoperative time points. Hemodynamic state interpretability varied over time and was highest before surgery (90%) and lowest on the first postoperative day (49%) (p<0.01). This variation in interpretability over time was reflected in all 3 transthoracic windows, ranging from 43% to 80% before surgery and from 2% to 35% on the first postoperative day (p<0.01). Image quality scores were highest with the apical window, ranging from 53% to 77% across time points, and lowest with the subcostal window, ranging from 4% to 70% across time points (p< 0.01). Hemodynamic state can be determined with TTE in a high proportion of cardiac surgery patients after extubation and removal of surgical drains. Copyright © 2017 Elsevier Inc. All rights reserved.
Economic Efficiency and Investment Timing for Dual Water Systems
NASA Astrophysics Data System (ADS)
Leconte, Robert; Hughes, Trevor C.; Narayanan, Rangesan
1987-10-01
A general methodology to evaluate the economic feasibility of dual water systems is presented. In a first step, a static analysis (evaluation at a single point in time) is developed. The analysis requires the evaluation of consumers' and producer's surpluses from water use and the capital cost of the dual (outdoor) system. The analysis is then extended to a dynamic approach where the water demand increases with time (as a result of a population increase) and where the dual system is allowed to expand. The model determines whether construction of a dual system represents a net benefit, and if so, what is the best time to initiate the system (corresponding to maximization of social welfare). Conditions under which an analytic solution is possible are discussed and results of an application are summarized (including sensitivity to different parameters). The analysis allows identification of key parameters influencing attractiveness of dual water systems.
NASA Astrophysics Data System (ADS)
Stratul, Stefan-Ioan; Sinescu, Cosmin; Negrutiu, Meda; de Sabata, Aldo; Rominu, Mihai; Ogodescu, Alexandru; Rusu, Darian
2014-01-01
Holographic evaluations count among recent measurement tools in orthodontics and prosthodontics. This research introduces holography as an assessment method of 3D variations of gingival retractions. The retraction of gingiva on frontal regions of 5 patients with periodontitis was measured in six points and was evaluated by holographic methods using a He-Ne laser device (1mV, Superlum, Carrigtwohill, Ireland) inside a holographic bank of 200 x 100cm. Impressions were taken during first visit and cast models were manufactured. Six months after the end of periodontal treatment, clinical measurements were repeated and the hologram of the first model was superimposed on a final model cast, by using reference points, while maintaining the optical geometric perimeters. The retractions were evaluated 3D in every point using a dedicated software (Sigma Scan Pro,Systat Software, SanJose, CA, USA). The Wilcoxon test was used to compare the mean recession changes between baseline and six months after treatment, and between values in vivo and the values on hologram. No statistically significant differences between values in vivo and on the hologram were found. In conclusion, holography provides a valuable tool for assessing gingival retractions on virtual models. The data can be stored, reproduced, transmitted and compared at a later time point with accuracy.
Kotani, Akira; Tsutsumi, Risa; Shoji, Asaki; Hayashi, Yuzuru; Kusu, Fumiyo; Yamamoto, Kazuhiro; Hakamata, Hideki
2016-07-08
This paper puts forward a time and material-saving method for evaluating the repeatability of area measurements in gradient HPLC with UV detection (HPLC-UV), based on the function of mutual information (FUMI) theory which can theoretically provide the measurement standard deviation (SD) and detection limits through the stochastic properties of baseline noise with no recourse to repetitive measurements of real samples. The chromatographic determination of terbinafine hydrochloride and enalapril maleate is taken as an example. The best choice of the number of noise data points, inevitable for the theoretical evaluation, is shown to be 512 data points (10.24s at 50 point/s sampling rate of an A/D converter). Coupled with the relative SD (RSD) of sample injection variability in the instrument used, the theoretical evaluation is proved to give identical values of area measurement RSDs to those estimated by the usual repetitive method (n=6) over a wide concentration range of the analytes within the 95% confidence intervals of the latter RSD. The FUMI theory is not a statistical one, but the "statistical" reliability of its SD estimates (n=1) is observed to be as high as that attained by thirty-one measurements of the same samples (n=31). Copyright © 2016 Elsevier B.V. All rights reserved.
Montella, Alfonso; Imbriani, Lella Liana; Marzano, Vittorio; Mauriello, Filomena
2015-02-01
In this paper, we evaluated the effects on speed and safety of the point-to-point (P2P) speed enforcement system activated on the urban motorway A56 in Italy. The P2P speed enforcement is a relatively new approach to traffic law enforcement that involves the calculation of the average speed over a section. To evaluate the speed effects, we performed a before-after analysis of speed data investigating also effects on non-compliance to speed limits. To evaluate the safety effects, we carried out an empirical Bayes observational before-and-after study. The P2P system led to very positive effects on both speed and safety. As far as the effects on the section average travel speeds, the system yielded to a reduction in the mean speed, the 85th percentile speed, the standard deviation of speed, and the proportion of drivers exceeding the speed limits, exceeding the speed limits more than 10km/h, and exceeding the speed limits more than 20km/h. The best results were the decrease of the speed variability and the reduction of the excessive speeding behaviour. The decrease in the standard deviation of speed was 26% while the proportion of light and heavy vehicles exceeding the speed limits more than 20km/h was reduced respectively by 84 and 77%. As far as the safety effects, the P2P system yielded to a 32% reduction in the total crashes, with a lower 95% confidence limit of the estimate equal to 22%. The greatest crash reductions were in rainy weather (57%), on wet pavement (51%), on curves (49%), for single vehicle crashes (44%), and for injury crashes (37%). It is noteworthy that the system produced a statistically significant reduction of 21% in total crashes also in the part of the motorway where it was not activated, thus generating a significant spillover effect. The investigation of the effects of the P2P system on speed and safety over time allowed to develop crash modification functions where the relationship between crash modification factors and speed parameters (mean speed, 85th percentile speed, and standard deviation of speed) was expressed by a power function. Crash modification functions show that the effect of speed on safety is greater on curves and for injury crashes. Even though the study results show excellent outcomes, we must point out that the crash reduction effects decreased over time and speed, speed variability, and non-compliance to speed limits significantly increased over time. To maintain its effectiveness over time, P2P speed enforcement must be actively managed, i.e. constantly monitored and supported by appropriate sanctions. Copyright © 2014 Elsevier Ltd. All rights reserved.
Extensions to the visual predictive check to facilitate model performance evaluation.
Post, Teun M; Freijer, Jan I; Ploeger, Bart A; Danhof, Meindert
2008-04-01
The Visual Predictive Check (VPC) is a valuable and supportive instrument for evaluating model performance. However in its most commonly applied form, the method largely depends on a subjective comparison of the distribution of the simulated data with the observed data, without explicitly quantifying and relating the information in both. In recent adaptations to the VPC this drawback is taken into consideration by presenting the observed and predicted data as percentiles. In addition, in some of these adaptations the uncertainty in the predictions is represented visually. However, it is not assessed whether the expected random distribution of the observations around the predicted median trend is realised in relation to the number of observations. Moreover the influence of and the information residing in missing data at each time point is not taken into consideration. Therefore, in this investigation the VPC is extended with two methods to support a less subjective and thereby more adequate evaluation of model performance: (i) the Quantified Visual Predictive Check (QVPC) and (ii) the Bootstrap Visual Predictive Check (BVPC). The QVPC presents the distribution of the observations as a percentage, thus regardless the density of the data, above and below the predicted median at each time point, while also visualising the percentage of unavailable data. The BVPC weighs the predicted median against the 5th, 50th and 95th percentiles resulting from a bootstrap of the observed data median at each time point, while accounting for the number and the theoretical position of unavailable data. The proposed extensions to the VPC are illustrated by a pharmacokinetic simulation example and applied to a pharmacodynamic disease progression example.
Another Look at the Great Area-Coverage Controversy of the 1950's
NASA Astrophysics Data System (ADS)
Blanchard, Walter
2005-09-01
In the immediate aftermath of WW2 there sprang up an international argument over the relative merits for aerial navigation of area-coverage radio navaids versus point-source systems. The United States was in favour of point-source whereas the UK proposed area-coverage, systems for which had successfully been demonstrated under very adverse conditions during the war. It rumbled on for many years, not being finally settled until the ICAO Montreal Conference of 1959 decided for point-source. Since then, VOR/DME/ADF/ILS have been the standard aviation radio navaids and there seems little likelihood of any change in the near future, GNSS notwithstanding, if one discounts the phasing-out of ADF. It now seems sufficiently in the past to perhaps allow a dispassionate evaluation of the technical arguments used at the time the political ones can be left to another place and time.
Pointing Device Performance in Steering Tasks.
Senanayake, Ransalu; Goonetilleke, Ravindra S
2016-06-01
Use of touch-screen-based interactions is growing rapidly. Hence, knowing the maneuvering efficacy of touch screens relative to other pointing devices is of great importance in the context of graphical user interfaces. Movement time, accuracy, and user preferences of four pointing device settings were evaluated on a computer with 14 participants aged 20.1 ± 3.13 years. It was found that, depending on the difficulty of the task, the optimal settings differ for ballistic and visual control tasks. With a touch screen, resting the arm increased movement time for steering tasks. When both performance and comfort are considered, whether to use a mouse or a touch screen for person-computer interaction depends on the steering difficulty. Hence, a input device should be chosen based on the application, and should be optimized to match the graphical user interface. © The Author(s) 2016.
Della Pepa, Giuseppe Maria; Sabatino, Giovanni; Sturiale, Carmelo Lucio; Marchese, Enrico; Puca, Alfredo; Olivi, Alessandro; Albanese, Alessio
2018-04-01
In the surgical treatment of spinal dural arteriovenous fistulas (DAVFs), intraoperative definition of anatomic characteristics of the DAVF and identification of the fistulous point is mandatory to effectively exclude the DAVF. Intraoperative ultrasound and contrast-enhanced ultrasound integrated with color Doppler ultrasound was applied in the surgical setting for a cervical DAVF to identify the fistulous point and evaluate correct occlusion of the fistula. Integration of intraoperative ultrasound and contrast-enhanced ultrasound is a simple, cost-effective technique that provides an opportunity for real-time dynamic visualization of DAVF vascular patterns, identification of the fistulous point, and assessment of correct exclusion. Compared with other intraoperative tools, such as indocyanine green videoangiography, it allows the surgeon to visualize hidden anatomic and vascular structures, minimizing surgical manipulation and guiding the surgeon during resection. Copyright © 2018 Elsevier Inc. All rights reserved.
Impact of a personalised active labour market programme for persons with disabilities.
Adamecz-Völgyi, Anna; Lévay, Petra Zsuzsa; Bördős, Katalin; Scharle, Ágota
2018-02-01
The paper estimates the impact of a supported employment programme implemented in Hungary. This is a non-experimental evaluation using a matching identification strategy supported by rich data on individual characteristics, personal employment and unemployment history and the local labour market situation. We use a time-window approach to ensure that programme participants and matched controls entered unemployment at the same point in time, and thus faced very similar labour market conditions. We find that the programme had a positive effect of 16 percentage points on the probability of finding a job among men and 25 percentage points among women. The alternative outcome indicator of not re-entering the unemployment registry shows somewhat smaller effects in the case of women. In comparison to similarly costly programmes that do not facilitate employment in the primary labour market, rehabilitation services represent a viable alternative.
DTM Generation with Uav Based Photogrammetric Point Cloud
NASA Astrophysics Data System (ADS)
Polat, N.; Uysal, M.
2017-11-01
Nowadays Unmanned Aerial Vehicles (UAVs) are widely used in many applications for different purposes. Their benefits however are not entirely detected due to the integration capabilities of other equipment such as; digital camera, GPS, or laser scanner. The main scope of this paper is evaluating performance of cameras integrated UAV for geomatic applications by the way of Digital Terrain Model (DTM) generation in a small area. In this purpose, 7 ground control points are surveyed with RTK and 420 photographs are captured. Over 30 million georeferenced points were used in DTM generation process. Accuracy of the DTM was evaluated with 5 check points. The root mean square error is calculated as 17.1 cm for an altitude of 100 m. Besides, a LiDAR derived DTM is used as reference in order to calculate correlation. The UAV based DTM has o 94.5 % correlation with reference DTM. Outcomes of the study show that it is possible to use the UAV Photogrammetry data as map producing, surveying, and some other engineering applications with the advantages of low-cost, time conservation, and minimum field work.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, R; Zhu, X; Li, S
Purpose: High Dose Rate (HDR) brachytherapy forward planning is principally an iterative process; hence, plan quality is affected by planners’ experiences and limited planning time. Thus, this may lead to sporadic errors and inconsistencies in planning. A statistical tool based on previous approved clinical treatment plans would help to maintain the consistency of planning quality and improve the efficiency of second checking. Methods: An independent dose calculation tool was developed from commercial software. Thirty-three previously approved cervical HDR plans with the same prescription dose (550cGy), applicator type, and treatment protocol were examined, and ICRU defined reference point doses (bladder, vaginalmore » mucosa, rectum, and points A/B) along with dwell times were collected. Dose calculation tool then calculated appropriate range with a 95% confidence interval for each parameter obtained, which would be used as the benchmark for evaluation of those parameters in future HDR treatment plans. Model quality was verified using five randomly selected approved plans from the same dataset. Results: Dose variations appears to be larger at the reference point of bladder and mucosa as compared with rectum. Most reference point doses from verification plans fell between the predicted range, except the doses of two points of rectum and two points of reference position A (owing to rectal anatomical variations & clinical adjustment in prescription points, respectively). Similar results were obtained for tandem and ring dwell times despite relatively larger uncertainties. Conclusion: This statistical tool provides an insight into clinically acceptable range of cervical HDR plans, which could be useful in plan checking and identifying potential planning errors, thus improving the consistency of plan quality.« less
Barcelos, Filipe; Patto, José Vaz; Parente, Manuela; Medeiros, Dina; Sousa, Miguel; Figueiredo, Rui; Miguel, Cláudia; Teixeira, Ana
2009-01-01
To evaluate the applicability and utility of unstimulated syalometry and instruments of evaluation of sicca complaints in a Sjögren's syndrome outpatient clinic. We performed unstimulated syalometry to 45 consecutive Primary Sjögren's Syndrome patients (PSS) and 21 healthy asymptomatic individuals age and sex-matched. PSS patients were further evaluated with Schirmer's test. We applied 3 published questionnaires to PSS patients: Xerostomia Inventory (XI), Oral Health Impact Profile-short form (OHIP) and Ocular Surface Disease Index (OSDI), and correlated the results with syalometry and Schirmer's test. Statistical analysis was performed with SPSS (Mann-Whitney U-test and Spearman's correlation). Salivary flux was significantly lower in PSS patients, as compared to controls (0.08+/-0.01 ml/min versus 0.38+/-0.25 ml/min, p=0.000), and decreased with age. Syalometry didn't correlate with Schirmer's test. OHIP scores (mean 26.8 points, ranging from 2 to 43 for a maximum of 56 points) didn't correlate with syalometry neither with Schirmer's test, but showed an association with the XI (p<0.0005) and OSDI (p<0.0005) tests. The XI questionnaire (mean 28.4 points, ranging from 11 to 41 for a maximum of 44 points) correlated with syalometry (p=0.018), with the OHIP questionary (p<0.0005) and with the OSDI scale (p=0.004), although it didn't correlate with Schirmer's test. OSDI scores (mean 56.5 points, ranging from 7 to 90 for a maximum of 100 points) didn't correlate with Schirmer's test neither with syalometry, but associated with the XI (p=0.004) and OHIP (p<0.0005) scales. Unstimulated syalometry is useful in the evaluation of patients suspected of suffering from Sjögren's syndrome, since it can confirm salivary hypofunction in a quick and cheap manner, allowing to differentiate between healthy individuals and patients. In a specialized clinic, the immediate availability of a salivary functional test is important in the classification of PSS or sicca syndrome. The xerostomia and xerophtalmia impact scales were mutually concordant, and since they evaluate the effects of the disease through time, could be helpful in our daily consultation.
Polynomial complexity despite the fermionic sign
NASA Astrophysics Data System (ADS)
Rossi, R.; Prokof'ev, N.; Svistunov, B.; Van Houcke, K.; Werner, F.
2017-04-01
It is commonly believed that in unbiased quantum Monte Carlo approaches to fermionic many-body problems, the infamous sign problem generically implies prohibitively large computational times for obtaining thermodynamic-limit quantities. We point out that for convergent Feynman diagrammatic series evaluated with a recently introduced Monte Carlo algorithm (see Rossi R., arXiv:1612.05184), the computational time increases only polynomially with the inverse error on thermodynamic-limit quantities.
Capponi, Rebecca; Loguercio, Valentina; Guerrini, Stefania; Beltrami, Giampietro; Vesprini, Andrea; Giostra, Fabrizio
2017-01-16
Pain evaluation at triage in Emergency Department (ED) is fundamental, as it influences significantly patients color code determination. Different scales have been proposed to quantify pain but they are not always reliable. This study aims to determine a) how important is for triage nurses pain measurement b) reliability of Numeric Rating Scale (NRS), the most used instrument to evaluate pain in Italian EDs, because it frequently shows higher pain scores than others scales. End point 1: a questionnaire was administered to triage nurses in some hospitals of northern Italy. End point 2: 250 patients arriving at the ED referring pain have been evaluated using, randomly, either the NRS or a fake "30-50" scale. End point 1: Triage nurses acknowledge to modify frequently the referred pain intensity. This for several reasons: nurses think that patients may exaggerate to obtain a higher priority color code; they may be influenced by specific patients categories (non EU citizens, drugs-addicted, elderly); the pain score referred by patients is not correspondent to nurse perception. End point 2: Data show that the mean value obtained with NRS is significantly (p<0.05) higher that the mean obtained with the "30-50" scale. Manipulation on pain evaluation performed by nurses might result in a dangerous underestimation of this symptom. At the same time, the use of NRS seems to allow patients to exaggerate pain perception with consequent altered attribution of color code at triage.
Putting Together a Blue Sky: Laying the Foundation for Staff Evaluation
ERIC Educational Resources Information Center
Searcy, Jeny
2012-01-01
Evaluation time can be like putting together a 5,000-piece jigsaw puzzle that is all sky--what, exactly, is the point? When all is said and done, one ends up with a big blue blob--nothing to show for all the effort. However, it doesn't have to be that way. Performance reviews can and should be an effective means of communication for both parties…
Barnhart, Matthew D; Maritato, Karl; Schankereli, Kemal; Wotton, Harry; Naber, Steven
2016-11-23
Evaluate the short-term outcomes of a novel synthetic ligament for treatment of naturally occurring canine cranial cruciate ligament disease. Prospective clinical study. Dogs with unilateral cranial cruciate ligament disease (n = 50). Patient parameters evaluated included a five-point lameness score, evaluation of craniocaudal stifle instability, and radiographic findings over 24 weeks. Any postoperative complications were recorded. Thirty-four out of 42 dogs experienced significant improvements in lameness between the preoperative and 24 week time points. Lameness scores in those dogs improved significantly at all measured time intervals after postoperative week 2. Recurrence of stifle instability increased significantly over the study period from immediate postoperative measurements. Cranial drawer recurred in seven out of 42 of dogs by week 4 and 18/42 by week 24. Implant changes were not noted between the immediate and six-month postoperative radiographs except where complications occurred. Overall, 25 dogs experienced a total of 32 complications (22 major and 10 minor). Sixteen dogs had major complications, and nine had minor complications. The procedure was generally effective at improving lameness scores, but did not consistently maintain postoperative stifle stability and had an unacceptably high complication rate. This synthetic ligament procedure cannot be recommended for use in its current form.
NASA Technical Reports Server (NTRS)
Sahai, Ranjana; Pierce, Larry; Cicolani, Luigi; Tischler, Mark
1998-01-01
Helicopter slung load operations are common in both military and civil contexts. The slung load adds load rigid body modes, sling stretching, and load aerodynamics to the system dynamics, which can degrade system stability and handling qualities, and reduce the operating envelope of the combined system below that of the helicopter alone. Further, the effects of the load on system dynamics vary significantly among the large range of loads, slings, and flight conditions that a utility helicopter will encounter in its operating life. In this context, military helicopters and loads are often qualified for slung load operations via flight tests which can be time consuming and expensive. One way to reduce the cost and time required to carry out these tests and generate quantitative data more readily is to provide an efficient method for analysis during the flight, so that numerous test points can be evaluated in a single flight test, with evaluations performed in near real time following each test point and prior to clearing the aircraft to the next point. Methodology for this was implemented at Ames and demonstrated in slung load flight tests in 1997 and was improved for additional flight tests in 1999. The parameters of interest for the slung load tests are aircraft handling qualities parameters (bandwidth and phase delay), stability margins (gain and phase margin), and load pendulum roots (damping and natural frequency). A procedure for the identification of these parameters from frequency sweep data was defined using the CIFER software package. CIFER is a comprehensive interactive package of utilities for frequency domain analysis previously developed at Ames for aeronautical flight test applications. It has been widely used in the US on a variety of aircraft, including some primitive flight time analysis applications.
NASA Astrophysics Data System (ADS)
Jakoby, Bjoern W.; Bercier, Yanic; Watson, Charles C.; Bendriem, Bernard; Townsend, David W.
2009-06-01
A new combined lutetium oxyorthosilicate (LSO) PET/CT scanner with an extended axial field-of-view (FOV) of 21.8 cm has been developed (Biograph TruePoint PET/CT with TrueV; Siemens Molecular Imaging) and introduced into clinical practice. The scanner includes the recently announced point spread function (PSF) reconstruction algorithm. The PET components incorporate four rings of 48 detector blocks, 5.4 cm times 5.4 cm in cross-section. Each block comprises a 13 times 13 matrix of 4 times 4 times 20 mm3 elements. Data are acquired with a 4.5 ns coincidence time window and an energy window of 425-650 keV. The physical performance of the new scanner has been evaluated according to the recently revised National Electrical Manufacturers Association (NEMA) NU 2-2007 standard and the results have been compared with a previous PET/CT design that incorporates three rings of block detectors with an axial coverage of 16.2 cm (Biograph TruePoint PET/CT; Siemens Molecular Imaging). In addition to the phantom measurements, patient Noise Equivalent Count Rates (NECRs) have been estimated for a range of patients with different body weights (42-154 kg). The average spatial resolution is the same for both scanners: 4.4 mm (FWHM) and 5.0 mm (FWHM) at 1 cm and 10 cm respectively from the center of the transverse FOV. The scatter fractions of the Biograph TruePoint and Biograph TruePoint TrueV are comparable at 32%. Compared to the three ring design, the system sensitivity and peak NECR with smoothed randoms correction (1R) increase by 82% and 73%, respectively. The increase in sensitivity from the extended axial coverage of the Biograph TruePoint PET/CT with TrueV should allow a decrease in either scan time or injected dose without compromising diagnostic image quality. The contrast improvement with the PSF reconstruction potentially offers enhanced detectability for small lesions.
Kwon, S R; Meharry, M; Oyoyo, U; Li, Y
2015-01-01
To evaluate the efficacy of do-it-yourself (DIY) whitening as compared to conventional tooth whitening modalities using different shade assessment tools. Extracted human molars (120) were randomly distributed to six groups (n=20). Whitening was performed according to manufacturer's directions for over-the-counter, dentist-dispensed for home use, and in-office whitening. DIY whitening consisted of a strawberry and baking soda mix. Additionally, negative and positive controls were used. Two evaluators used the Vita Classical (VC) and Vita Bleachedguide 3D-Master with interpolated numbers (BGi) for visual assessment at baseline and one-week, one-month, and three-month postwhitening. Instrumental measurements were performed with a spectrophotometer. Kruskal-Wallis procedure was used to assess color changes among groups and intraclass correlation (ICC) to evaluate agreement between evaluators. DIY exhibited lower color change (ΔSGUVC, ΔSGUBGi, ΔE*, where SGU = shade guide unit and E = overall color change) compared to other whitening groups at all time points (p<0.05). ICC demonstrated very good agreement between evaluators with VC and BGi at each time point. Both shade guides were related with each other and strongly related to instrumental measurements (p<0.05). DIY whitening was the least effective whitening modality. Both VC and BGi are related with each other and have good correlation with instrumental measurements.
NASA Astrophysics Data System (ADS)
Jorgenson, J. C.; Jorgenson, M. T.; Boldenow, M.; Orndahl, K. M.
2016-12-01
We documented landscape change over a 60 year period in the Arctic National Wildlife Refuge in northeastern Alaska using aerial photographs and satellite images. We used a stratified random sample to allow inference to the whole refuge (78,050 km2), with five random sites in each of seven ecoregions. Each site (2 km2) had a systematic grid of 100 points for a total of 3500 points. We chose study sites in the overlap area covered by acceptable imagery in three time periods: aerial photographs from 1947 - 1955 and 1978 - 1988, Quick Bird and IKONOS satellite images from 2000 - 2007.At each point a 10 meter radius circle was visually evaluated in ARC-MAP for each time period for vegetation type, disturbance, presence of ice wedge polygon microtopography and surface water. A landscape change category was assigned to each point based on differences detected between the three periods. Change types were assigned for time interval 1, interval 2 and overall. Additional explanatory variables included elevation, slope, aspect, geology, physiography and temperature. Overall, 23% of points changed over the study period. Fire was the most common change agent, affecting 28% of the Boreal Forest points. The next most common change was degradation of soil ice wedges (thermokarst), detected at 12% of the points on the North Slope Tundra. The other most common changes included increase in cover of trees or shrubs (7% of Boreal Forest and Brooks Range points) and erosion or deposition on river floodplains and at the Beaufort Sea coast. Changes on the North Slope Tundra tended to be related to landscape wetting, mainly thermokarst. Changes in the Boreal Forest tended to involve landscape drying, including fire, reduced area of lakes and tree increase on wet sites. The second time interval coincided with a shift towards a warmer climate and had greater change in several categories including thermokarst, lake changes and tree and shrub increase.
Evaluating anesthetic protocols for functional blood flow imaging in the rat eye
NASA Astrophysics Data System (ADS)
Moult, Eric M.; Choi, WooJhon; Boas, David A.; Baumann, Bernhard; Clermont, Allen C.; Feener, Edward P.; Fujimoto, James G.
2017-01-01
The purpose of this study is to evaluate the suitability of five different anesthetic protocols (isoflurane, isoflurane-xylazine, pentobarbital, ketamine-xylazine, and ketamine-xylazine-vecuronium) for functional blood flow imaging in the rat eye. Total retinal blood flow was measured at a series of time points using an ultrahigh-speed Doppler OCT system. Additionally, each anesthetic protocol was qualitatively evaluated according to the following criteria: (1) time-stability of blood flow, (2) overall rate of blood flow, (3) ocular immobilization, and (4) simplicity. We observed that different anesthetic protocols produced markedly different blood flows. Different anesthetic protocols also varied with respect to the four evaluated criteria. These findings suggest that the choice of anesthetic protocol should be carefully considered when designing and interpreting functional blood flow studies in the rat eye.
Joiner, Logan C; Tynes, Clay; Arnold, John; Miller, Rachel R; Gorman, Greg
2018-04-01
Purpose: The purpose of this study was to determine the physical compatibility of micafungin with commonly used concentrations of sodium bicarbonate hydration fluids administered via a Y-site connected to a central venous catheter (Y-site/CVC). Methods: Micafungin sodium (evaluated concentration of 1.5 mg/mL) was combined in a 3:1 (vehicle:drug) ratio with the following commonly used hydration vehicles: 40 mEq/L sodium bicarbonate in 5% dextrose in water with ¼ normal saline (40SB-D5W-1/4NS), 75 mEq/L sodium bicarbonate in D5W (75SB-D5W), and 154 mEq/L sodium bicarbonate in D5W (154SB-D5W). A 3:1 ratio was used based on the flow rates (typically 125 mL/m 2 /h for bicarbonate-containing vehicles and 50 mL/h for micafungin) of the corresponding solutions in a clinical setting. Visual observations recorded to determine physical compatibility included visual inspection against different backgrounds (unaided, black, and white). Other physical observations were as follows: odor, evolution of gas, pH, and turbidity immediately recorded after mixing and at specified time points up to 2 hours. Evaluations at each time point were compared against baseline observation values at Time 0. Results: All combinations tested were found to be compatible up to 2 hours. Time points beyond 2 hours cannot be safely verified as compatible. Conclusion: Micafungin may be administered safely using a Y-site/CVC delivery system with all the vehicles tested in this study.
Kitaguchi, Nobuya; Hasegawa, Midori; Ito, Shinji; Kawaguchi, Kazunori; Hiki, Yoshiyuki; Nakai, Sigeru; Suzuki, Nobuo; Shimano, Yasunobu; Ishida, Osamu; Kushimoto, Hiroko; Kato, Masao; Koide, Sigehisa; Kanayama, Kyoko; Kato, Takashi; Ito, Kengo; Takahashi, Hiroshi; Mutoh, Tatsuro; Sugiyama, Satoshi; Yuzawa, Yukio
2015-11-01
To obtain the proof of concept of a novel therapy for Alzheimer's disease (AD), we conducted two prospective studies with hemodialysis patients who had amyloid β protein (Aβ) removed from their blood three times a week. One major pathological change in the brain associated with AD is Aβ deposition, mainly 40 amino acids Aβ1-40 and 42 amino acids Aβ1-42. Impaired Aβ clearance is proposed to be one cause of increased Aβ in the AD brain. Thus, we hypothesized that an extracorporeal removal system of Aβ from the blood may remove brain Aβ and be a useful therapeutic strategy for AD. In the first prospective study, plasma Aβ levels and the cognitive function of 30 hemodialysis patients (65-76 years old) were evaluated at baseline as well as 18 or 36 months after. Although plasma Aβ1-40 levels either decreased or remained unchanged, levels of Aβ1-42 either remained unchanged or increased at the second time point. Mini-Mental State Examination scores of most subjects increased or were maintained at the second time point. Aβ1-40 influx into the blood correlated with MMSE at the second time point. In the second prospective study, five patients (51-84 years old) with renal failure were evaluated before and after the initiation of hemodialysis. Plasma Aβ levels decreased, while cognitive function improved after initiating blood Aβ removal. Therefore, long-term hemodialysis, which effectively removes blood Aβ, might alter Aβ influx and help maintain cognitive function.
A point implicit time integration technique for slow transient flow problems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kadioglu, Samet Y.; Berry, Ray A.; Martineau, Richard C.
2015-05-01
We introduce a point implicit time integration technique for slow transient flow problems. The method treats the solution variables of interest (that can be located at cell centers, cell edges, or cell nodes) implicitly and the rest of the information related to same or other variables are handled explicitly. The method does not require implicit iteration; instead it time advances the solutions in a similar spirit to explicit methods, except it involves a few additional function(s) evaluation steps. Moreover, the method is unconditionally stable, as a fully implicit method would be. This new approach exhibits the simplicity of implementation ofmore » explicit methods and the stability of implicit methods. It is specifically designed for slow transient flow problems of long duration wherein one would like to perform time integrations with very large time steps. Because the method can be time inaccurate for fast transient problems, particularly with larger time steps, an appropriate solution strategy for a problem that evolves from a fast to a slow transient would be to integrate the fast transient with an explicit or semi-implicit technique and then switch to this point implicit method as soon as the time variation slows sufficiently. We have solved several test problems that result from scalar or systems of flow equations. Our findings indicate the new method can integrate slow transient problems very efficiently; and its implementation is very robust.« less
Kenngott, Hannes Götz; Preukschas, Anas Amin; Wagner, Martin; Nickel, Felix; Müller, Michael; Bellemann, Nadine; Stock, Christian; Fangerau, Markus; Radeleff, Boris; Kauczor, Hans-Ulrich; Meinzer, Hans-Peter; Maier-Hein, Lena; Müller-Stich, Beat Peter
2018-06-01
Augmented reality (AR) systems are currently being explored by a broad spectrum of industries, mainly for improving point-of-care access to data and images. Especially in surgery and especially for timely decisions in emergency cases, a fast and comprehensive access to images at the patient bedside is mandatory. Currently, imaging data are accessed at a distance from the patient both in time and space, i.e., at a specific workstation. Mobile technology and 3-dimensional (3D) visualization of radiological imaging data promise to overcome these restrictions by making bedside AR feasible. In this project, AR was realized in a surgical setting by fusing a 3D-representation of structures of interest with live camera images on a tablet computer using marker-based registration. The intent of this study was to focus on a thorough evaluation of AR. Feasibility, robustness, and accuracy were thus evaluated consecutively in a phantom model and a porcine model. Additionally feasibility was evaluated in one male volunteer. In the phantom model (n = 10), AR visualization was feasible in 84% of the visualization space with high accuracy (mean reprojection error ± standard deviation (SD): 2.8 ± 2.7 mm; 95th percentile = 6.7 mm). In a porcine model (n = 5), AR visualization was feasible in 79% with high accuracy (mean reprojection error ± SD: 3.5 ± 3.0 mm; 95th percentile = 9.5 mm). Furthermore, AR was successfully used and proved feasible within a male volunteer. Mobile, real-time, and point-of-care AR for clinical purposes proved feasible, robust, and accurate in the phantom, animal, and single-trial human model shown in this study. Consequently, AR following similar implementation proved robust and accurate enough to be evaluated in clinical trials assessing accuracy, robustness in clinical reality, as well as integration into the clinical workflow. If these further studies prove successful, AR might revolutionize data access at patient bedside.
Early arthroscopic release in stiff shoulder
Sabat, Dhananjaya; Kumar, Vinod
2008-01-01
Purpose: To evaluate the results of early arthroscopic release in the patients of stiff shoulder Methods: Twenty patients of stiff shoulder, who had symptoms for at least three months and failed to improve with steroid injections and physical therapy of 6 weeks duration, underwent arthroscopic release. The average time between onset of symptoms and the time of surgery was 4 months and 2 weeks. The functional outcome was evaluated using ASES and Constant and Murley scoring systems. Results: All the patients showed significant improvement in the range of motion and relief of pain by end of three months following the procedure. At 12 months, mean improvement in ASES score is 38 points and Constant and Murley score is 4O.5 points. All patients returned to work by 3-5 months (average -4.5 months). Conclusion: Early arthroscopic release showed promising results with reliable increase in range of motion, early relief of symptoms and consequent early return to work. So it is highly recommended in properly selected patients. Level of evidence: Level IV PMID:20300309
Kohal, Ralf Joachim; Straub, Lisa Marie; Wolkewitz, Martin; Bächle, Maria; Patzelt, Sebastian Berthold Maximilian
2015-10-01
To evaluate the potential of two bone substitute materials and the influence of different healing periods in guided bone regeneration therapy of osseous defects around implants. Twenty-four edentulous patients received implants in the region of the lost lower incisors. Around two standardized osseous defects were created, treated either with a 50:50 mixture of PepGen P-15® and OsteoGraf®/N-700 (test group) or with BioOss® (control group), and covered with titanium membranes. After healing periods of 2, 4, 6, or 9 months, the implants were removed together with the surrounding bone and subsequently prepared for histological evaluations. Defect depths in both groups showed a clinical reduction after intervention. The histologically measured distance from the implant shoulder to the first point of bone-implant contact (BIC) after treatment did not differ between the two groups. The healing time influenced the level of the first point of BIC, with a longer healing period producing a more coronal first point of BIC. A greater percentage BIC and a higher fraction of mineralized bone were found in the pristine bone area compared with the augmented defect area. It can be concluded that in the treatment of osseous defects around oral implants, both materials were equally effective bone substitute materials when used in combination with guided bone regeneration. © 2014 Wiley Periodicals, Inc.
Evaluation of new indigenous "point-of-care" ABO and Rh grouping device.
Tiwari, Aseem Kumar; Setya, Divya; Aggarwal, Geet; Arora, Dinesh; Dara, Ravi C; Ratan, Ankita; Bhardwaj, Gunjan; Acharya, Devi Prasad
2018-01-01
Erycard 2.0 is a "point-of-care" device that is primarily being used for patient blood grouping before transfusion. Erycard 2.0 was compared with conventional slide technology for accuracy and time taken for ABO and Rh forward grouping result with column agglutination technology (CAT) being the gold standard. Erycard 2.0 as a device was also evaluated for its stability under different storage conditions and stability of result till 48 h. In addition, grouping of hemolyzed samples was also tested with Erycard 2.0. Ease of use of Erycard 2.0 was evaluated with a survey among paramedical staff. Erycard 2.0 demonstrated 100% concordance with CAT as compared with slide technique (98.9%). Mean time taken per test by Erycard 2.0 and slide technique was 5.13 min and 1.7 min, respectively. After pretesting storage under different temperature and humidity conditions, Erycard 2.0 did not show any deviation from the result. The result did not change even after 48 h of testing and storage under room temperature. 100% concordance was recorded between pre- and post-hemolyzed blood grouping. Ease of use survey revealed that Erycard 2.0 was more acceptable to paramedical staff for its simplicity, objectivity, and performance than conventional slide technique. Erycard 2.0 can be used as "point-of-care" device for blood donor screening for ABO and Rh blood group and can possibly replace conventional slide technique.
Evaluation of new indigenous “point-of-care” ABO and Rh grouping device
Tiwari, Aseem Kumar; Setya, Divya; Aggarwal, Geet; Arora, Dinesh; Dara, Ravi C.; Ratan, Ankita; Bhardwaj, Gunjan; Acharya, Devi Prasad
2018-01-01
BACKGROUND: Erycard 2.0 is a “point-of-care” device that is primarily being used for patient blood grouping before transfusion. MATERIALS AND METHODS: Erycard 2.0 was compared with conventional slide technology for accuracy and time taken for ABO and Rh forward grouping result with column agglutination technology (CAT) being the gold standard. Erycard 2.0 as a device was also evaluated for its stability under different storage conditions and stability of result till 48 h. In addition, grouping of hemolyzed samples was also tested with Erycard 2.0. Ease of use of Erycard 2.0 was evaluated with a survey among paramedical staff. RESULTS: Erycard 2.0 demonstrated 100% concordance with CAT as compared with slide technique (98.9%). Mean time taken per test by Erycard 2.0 and slide technique was 5.13 min and 1.7 min, respectively. After pretesting storage under different temperature and humidity conditions, Erycard 2.0 did not show any deviation from the result. The result did not change even after 48 h of testing and storage under room temperature. 100% concordance was recorded between pre- and post-hemolyzed blood grouping. Ease of use survey revealed that Erycard 2.0 was more acceptable to paramedical staff for its simplicity, objectivity, and performance than conventional slide technique. CONCLUSION: Erycard 2.0 can be used as “point-of-care” device for blood donor screening for ABO and Rh blood group and can possibly replace conventional slide technique. PMID:29403211
Lassau, Nathalie; Bonastre, Julia; Kind, Michèle; Vilgrain, Valérie; Lacroix, Joëlle; Cuinet, Marie; Taieb, Sophie; Aziza, Richard; Sarran, Antony; Labbe-Devilliers, Catherine; Gallix, Benoit; Lucidarme, Olivier; Ptak, Yvette; Rocher, Laurence; Caquot, Louis-Michel; Chagnon, Sophie; Marion, Denis; Luciani, Alain; Feutray, Sylvaine; Uzan-Augui, Joëlle; Coiffier, Benedicte; Benastou, Baya; Koscielny, Serge
2014-12-01
Dynamic contrast-enhanced ultrasound (DCE-US) has been used in single-center studies to evaluate tumor response to antiangiogenic treatments: the change of area under the perfusion curve (AUC), a criterion linked to blood volume, was consistently correlated with the Response Evaluation Criteria in Solid Tumors response. The main objective here was to do a multicentric validation of the use of DCE-US to evaluate tumor response in different solid tumor types treated by several antiangiogenic agents. A secondary objective was to evaluate the costs of the procedure. This prospective study included patients from 2007 to 2010 in 19 centers (8 teaching hospitals and 11 comprehensive cancer centers). All patients treated with antiangiogenic therapy were eligible. Dynamic contrast-enhanced ultrasound examinations were performed at baseline as well as on days 7, 15, 30, and 60. For each examination, a perfusion curve was recorded during 3 minutes after injection of a contrast agent. Change from baseline at each time point was estimated for each of 7 fitted criteria. The main end point was freedom from progression (FFP). Criterion/time-point combinations with the strongest correlation with FFP were analyzed further to estimate an optimal cutoff point. A total of 1968 DCE-US examinations in 539 patients were analyzed. The median follow-up was 1.65 years. Variations from baseline were significant at day 30 for several criteria, with AUC having the most significant association with FFP (P = 0.00002). Patients with a greater than 40% decrease in AUC at day 30 had better FFP (P = 0.005) and overall survival (P = 0.05). The mean cost of each DCE-US was 180&OV0556;, which corresponds to $250 using the current exchange rate. Dynamic contrast-enhanced ultrasound is a new functional imaging technique that provides a validated criterion, namely, the change of AUC from baseline to day 30, which is predictive of tumor progression in a large multicenter cohort. Because of its low cost, it should be considered in the routine evaluation of solid tumors treated with antiangiogenic therapy.
Optimized stereo matching in binocular three-dimensional measurement system using structured light.
Liu, Kun; Zhou, Changhe; Wei, Shengbin; Wang, Shaoqing; Fan, Xin; Ma, Jianyong
2014-09-10
In this paper, we develop an optimized stereo-matching method used in an active binocular three-dimensional measurement system. A traditional dense stereo-matching algorithm is time consuming due to a long search range and the high complexity of a similarity evaluation. We project a binary fringe pattern in combination with a series of N binary band limited patterns. In order to prune the search range, we execute an initial matching before exhaustive matching and evaluate a similarity measure using logical comparison instead of a complicated floating-point operation. Finally, an accurate point cloud can be obtained by triangulation methods and subpixel interpolation. The experiment results verify the computational efficiency and matching accuracy of the method.
Gopaul, Remona; Knaggs, Helen E; Lephart, Janet F; Holley, Kara C; Gibson, Erica M
2010-09-01
There are many different visible signs of skin aging. These include wrinkles, hyperpigmentation, lack of firmness, poor texture, enlarged pores, and dryness. While there are many topical agents that claim to deliver wide-spectrum anti-aging benefits, few target all of the signs of skin aging to the same extent. Salicin, an extract from white willow bark, has been researched as a potent anti-inflammatory agent when taken orally. Based on unpublished in-house comprehensive consumer clinical studies, it is believed salicin may have anti-aging capabilities when applied topically to human skin. This research evaluated the effect of a topical serum formulation containing salicin at 0.5% on the visible signs of skin aging. This single-center study enrolled 30 female subjects, showing mild to moderate signs of aging, between the ages of 35 and 70 having Fitzpatrick skin types ranging between I and IV. Subjects used the study serum product containing 0.5% salicin on their face twice daily for 12 weeks. Ordinal grading on a nine-point scale (0 = none, 1-3 = mild, 4-6 = moderate, 7-9 = severe) of facial fine lines, molted pigmentation, uneven skin tone, tactile roughness, global firmness appearance, jaw-line contour, radiance, and overall appearance was performed by investigator at baseline, week 1, week 4, week 8, and week 12. Digital photography, ultrasound, cutometry, and corneometry measurements were also performed at each time point. Twenty-nine of 30 subjects successfully completed the study. No tolerability issues were reported. The clinical investigator found statistically significant improvements in wrinkles, tactile roughness, pore size, radiance, and overall appearance at week 1 time point (P ≤ 0.05) against baseline and statistically significant improvements in mottled pigmentation, global firmness, and jaw-line contour at week 4 time point (P ≤ 0.05) against baseline. Cutometry, corneometry, and ultrasound measurements showed significant improvements at week 12 time point (P ≤ 0.05) against baseline. Based on the findings from this study, it can be concluded that salicin has the ability to reduce the visible signs of skin aging when applied topically. © 2010 Wiley Periodicals, Inc.
Chiesa, Luca Maria; Pasquale, Elisa; Panseri, Sara; Britti, Domenico; Malandra, Renato; Villa, Roberto; Arioli, Francesco
2017-03-01
A method based on headspace solid-phase microextraction (HS-SPME) followed by GC-MS analysis was developed for the determination of underivatised acetic acid in fresh tuna fish muscle. Parameters such as the fibre selected and the extraction time and temperature were optimised and the linearity, detection limits and precision of the whole analytical procedure were assessed. The method was then applied to determine the acetic acid concentration in fresh yellowfin tuna muscles (Thunnus albacares) in order to evaluate the endogenous level and its variations during the shelf life under different storage conditions. A qualitative comparison was also made with variations in histamine levels to evaluate the possibility of the joint monitoring of acetic acid and histamine to identify fish stored in poor conditions. The caudal area always had a lower content of acetic acid than the ventral area, independent of the storage time and temperature. A difference was found between the 6- and 3-day time points and day 0 at a storage temperature of 8°C and between the 6-day time point and day 0 at a storage temperature of 0°C, independent of the anatomical area of the sampled tissue. The evaluation of acetic acid could represent an important approach in the field of food safety to detect the illicit use of acetic acid as an antibacterial preservative treatment or to eliminate the unpleasant smell of trimethylamine.
Experimental and numerical analysis of metal leaching from fly ash-amended highway bases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cetin, Bora; Aydilek, Ahmet H., E-mail: aydilek@umd.edu; Li, Lin
2012-05-15
Highlights: Black-Right-Pointing-Pointer This study is the evaluation of leaching potential of fly ash-lime mixed soils. Black-Right-Pointing-Pointer This objective is met with experimental and numerical analysis. Black-Right-Pointing-Pointer Zn leaching decreases with increase in fly ash content while Ba, B, Cu increases. Black-Right-Pointing-Pointer Decrease in lime content promoted leaching of Ba, B and Cu while Zn increases. Black-Right-Pointing-Pointer Numerical analysis predicted lower field metal concentrations. - Abstract: A study was conducted to evaluate the leaching potential of unpaved road materials (URM) mixed with lime activated high carbon fly ashes and to evaluate groundwater impacts of barium, boron, copper, and zinc leaching. Thismore » objective was met by a combination of batch water leach tests, column leach tests, and computer modeling. The laboratory tests were conducted on soil alone, fly ash alone, and URM-fly ash-lime kiln dust mixtures. The results indicated that an increase in fly ash and lime content has significant effects on leaching behavior of heavy metals from URM-fly ash mixture. An increase in fly ash content and a decrease in lime content promoted leaching of Ba, B and Cu whereas Zn leaching was primarily affected by the fly ash content. Numerically predicted field metal concentrations were significantly lower than the peak metal concentrations obtained in laboratory column leach tests, and field concentrations decreased with time and distance due to dispersion in soil vadose zone.« less
Evaluating lidar point densities for effective estimation of aboveground biomass
Wu, Zhuoting; Dye, Dennis G.; Stoker, Jason M.; Vogel, John M.; Velasco, Miguel G.; Middleton, Barry R.
2016-01-01
The U.S. Geological Survey (USGS) 3D Elevation Program (3DEP) was recently established to provide airborne lidar data coverage on a national scale. As part of a broader research effort of the USGS to develop an effective remote sensing-based methodology for the creation of an operational biomass Essential Climate Variable (Biomass ECV) data product, we evaluated the performance of airborne lidar data at various pulse densities against Landsat 8 satellite imagery in estimating above ground biomass for forests and woodlands in a study area in east-central Arizona, U.S. High point density airborne lidar data, were randomly sampled to produce five lidar datasets with reduced densities ranging from 0.5 to 8 point(s)/m2, corresponding to the point density range of 3DEP to provide national lidar coverage over time. Lidar-derived aboveground biomass estimate errors showed an overall decreasing trend as lidar point density increased from 0.5 to 8 points/m2. Landsat 8-based aboveground biomass estimates produced errors larger than the lowest lidar point density of 0.5 point/m2, and therefore Landsat 8 observations alone were ineffective relative to airborne lidar for generating a Biomass ECV product, at least for the forest and woodland vegetation types of the Southwestern U.S. While a national Biomass ECV product with optimal accuracy could potentially be achieved with 3DEP data at 8 points/m2, our results indicate that even lower density lidar data could be sufficient to provide a national Biomass ECV product with accuracies significantly higher than that from Landsat observations alone.
Preconditioning 2D Integer Data for Fast Convex Hull Computations.
Cadenas, José Oswaldo; Megson, Graham M; Luengo Hendriks, Cris L
2016-01-01
In order to accelerate computing the convex hull on a set of n points, a heuristic procedure is often applied to reduce the number of points to a set of s points, s ≤ n, which also contains the same hull. We present an algorithm to precondition 2D data with integer coordinates bounded by a box of size p × q before building a 2D convex hull, with three distinct advantages. First, we prove that under the condition min(p, q) ≤ n the algorithm executes in time within O(n); second, no explicit sorting of data is required; and third, the reduced set of s points forms a simple polygonal chain and thus can be directly pipelined into an O(n) time convex hull algorithm. This paper empirically evaluates and quantifies the speed up gained by preconditioning a set of points by a method based on the proposed algorithm before using common convex hull algorithms to build the final hull. A speedup factor of at least four is consistently found from experiments on various datasets when the condition min(p, q) ≤ n holds; the smaller the ratio min(p, q)/n is in the dataset, the greater the speedup factor achieved.
Healy, R.W.; Russell, T.F.
1992-01-01
A finite-volume Eulerian-Lagrangian local adjoint method for solution of the advection-dispersion equation is developed and discussed. The method is mass conservative and can solve advection-dominated ground-water solute-transport problems accurately and efficiently. An integrated finite-difference approach is used in the method. A key component of the method is that the integral representing the mass-storage term is evaluated numerically at the current time level. Integration points, and the mass associated with these points, are then forward tracked up to the next time level. The number of integration points required to reach a specified level of accuracy is problem dependent and increases as the sharpness of the simulated solute front increases. Integration points are generally equally spaced within each grid cell. For problems involving variable coefficients it has been found to be advantageous to include additional integration points at strategic locations in each well. These locations are determined by backtracking. Forward tracking of boundary fluxes by the method alleviates problems that are encountered in the backtracking approaches of most characteristic methods. A test problem is used to illustrate that the new method offers substantial advantages over other numerical methods for a wide range of problems.
Measurements of tungsten migration in the DIII-D divertor
NASA Astrophysics Data System (ADS)
Wampler, W. R.; Rudakov, D. L.; Watkins, J. G.; McLean, A. G.; Unterberg, E. A.; Stangeby, P. C.
2017-12-01
An experimental study of migration of tungsten in the DIII-D divertor is described, in which the outer strike point of L-mode plasmas was positioned on a toroidal ring of tungsten-coated metal inserts. Net deposition of tungsten on the divertor just outside the strike point was measured on graphite samples exposed to various plasma durations using the divertor materials evaluation system. Tungsten coverage, measured by Rutherford backscattering spectroscopy (RBS), was found to be low and nearly independent of both radius and exposure time closer to the strike point, whereas farther from the strike point the W coverage was much larger and increased with exposure time. Depth profiles from RBS show this was due to accumulation of thicker mixed-material deposits farther from the strike point where the plasma temperature is lower. These results are consistent with a low near-surface steady-state coverage on graphite undergoing net erosion, and continuing accumulation in regions of net deposition. This experiment provides data needed to validate, and further improve computational simulations of erosion and deposition of material on plasma-facing components and transport of impurities in magnetic fusion devices. Such simulations are underway and will be reported later.
Blaya, Joaquín A; Shin, Sonya; Contreras, Carmen; Yale, Gloria; Suarez, Carmen; Asencios, Luis; Kim, Jihoon; Rodriguez, Pablo; Cegielski, Peter; Fraser, Hamish S F
2011-01-01
To evaluate the time to communicate laboratory results to health centers (HCs) between the e-Chasqui web-based information system and the pre-existing paper-based system. Cluster randomized controlled trial in 78 HCs in Peru. In the intervention group, 12 HCs had web access to results via e-Chasqui (point-of-care HCs) and forwarded results to 17 peripheral HCs. In the control group, 22 point-of-care HCs received paper results directly and forwarded them to 27 peripheral HCs. Baseline data were collected for 15 months. Post-randomization data were collected for at least 2 years. Comparisons were made between intervention and control groups, stratified by point-of-care versus peripheral HCs. For point-of-care HCs, the intervention group took less time to receive drug susceptibility tests (DSTs) (median 9 vs 16 days, p<0.001) and culture results (4 vs 8 days, p<0.001) and had a lower proportion of 'late' DSTs taking >60 days to arrive (p<0.001) than the control. For peripheral HCs, the intervention group had similar communication times for DST (median 22 vs 19 days, p=0.30) and culture (10 vs 9 days, p=0.10) results, as well as proportion of 'late' DSTs (p=0.57) compared with the control. Only point-of-care HCs with direct access to the e-Chasqui information system had reduced communication times and fewer results with delays of >2 months. Peripheral HCs had no benefits from the system. This suggests that health establishments should have point-of-care access to reap the benefits of electronic laboratory reporting.
Shin, Sonya; Contreras, Carmen; Yale, Gloria; Suarez, Carmen; Asencios, Luis; Kim, Jihoon; Rodriguez, Pablo; Cegielski, Peter; Fraser, Hamish S F
2010-01-01
Objective To evaluate the time to communicate laboratory results to health centers (HCs) between the e-Chasqui web-based information system and the pre-existing paper-based system. Methods Cluster randomized controlled trial in 78 HCs in Peru. In the intervention group, 12 HCs had web access to results via e-Chasqui (point-of-care HCs) and forwarded results to 17 peripheral HCs. In the control group, 22 point-of-care HCs received paper results directly and forwarded them to 27 peripheral HCs. Baseline data were collected for 15 months. Post-randomization data were collected for at least 2 years. Comparisons were made between intervention and control groups, stratified by point-of-care versus peripheral HCs. Results For point-of-care HCs, the intervention group took less time to receive drug susceptibility tests (DSTs) (median 9 vs 16 days, p<0.001) and culture results (4 vs 8 days, p<0.001) and had a lower proportion of ‘late’ DSTs taking >60 days to arrive (p<0.001) than the control. For peripheral HCs, the intervention group had similar communication times for DST (median 22 vs 19 days, p=0.30) and culture (10 vs 9 days, p=0.10) results, as well as proportion of ‘late’ DSTs (p=0.57) compared with the control. Conclusions Only point-of-care HCs with direct access to the e-Chasqui information system had reduced communication times and fewer results with delays of >2 months. Peripheral HCs had no benefits from the system. This suggests that health establishments should have point-of-care access to reap the benefits of electronic laboratory reporting. PMID:21113076
Turbopump Performance Improved by Evolutionary Algorithms
NASA Technical Reports Server (NTRS)
Oyama, Akira; Liou, Meng-Sing
2002-01-01
The development of design optimization technology for turbomachinery has been initiated using the multiobjective evolutionary algorithm under NASA's Intelligent Synthesis Environment and Revolutionary Aeropropulsion Concepts programs. As an alternative to the traditional gradient-based methods, evolutionary algorithms (EA's) are emergent design-optimization algorithms modeled after the mechanisms found in natural evolution. EA's search from multiple points, instead of moving from a single point. In addition, they require no derivatives or gradients of the objective function, leading to robustness and simplicity in coupling any evaluation codes. Parallel efficiency also becomes very high by using a simple master-slave concept for function evaluations, since such evaluations often consume the most CPU time, such as computational fluid dynamics. Application of EA's to multiobjective design problems is also straightforward because EA's maintain a population of design candidates in parallel. Because of these advantages, EA's are a unique and attractive approach to real-world design optimization problems.
Evaluation strategies for isotope ratio measurements of single particles by LA-MC-ICPMS.
Kappel, S; Boulyga, S F; Dorta, L; Günther, D; Hattendorf, B; Koffler, D; Laaha, G; Leisch, F; Prohaska, T
2013-03-01
Data evaluation is a crucial step when it comes to the determination of accurate and precise isotope ratios computed from transient signals measured by multi-collector-inductively coupled plasma mass spectrometry (MC-ICPMS) coupled to, for example, laser ablation (LA). In the present study, the applicability of different data evaluation strategies (i.e. 'point-by-point', 'integration' and 'linear regression slope' method) for the computation of (235)U/(238)U isotope ratios measured in single particles by LA-MC-ICPMS was investigated. The analyzed uranium oxide particles (i.e. 9073-01-B, CRM U010 and NUSIMEP-7 test samples), having sizes down to the sub-micrometre range, are certified with respect to their (235)U/(238)U isotopic signature, which enabled evaluation of the applied strategies with respect to precision and accuracy. The different strategies were also compared with respect to their expanded uncertainties. Even though the 'point-by-point' method proved to be superior, the other methods are advantageous, as they take weighted signal intensities into account. For the first time, the use of a 'finite mixture model' is presented for the determination of an unknown number of different U isotopic compositions of single particles present on the same planchet. The model uses an algorithm that determines the number of isotopic signatures by attributing individual data points to computed clusters. The (235)U/(238)U isotope ratios are then determined by means of the slopes of linear regressions estimated for each cluster. The model was successfully applied for the accurate determination of different (235)U/(238)U isotope ratios of particles deposited on the NUSIMEP-7 test samples.
Evaluation of a high framerate multi-exposure laser speckle contrast imaging setup
NASA Astrophysics Data System (ADS)
Hultman, Martin; Fredriksson, Ingemar; Strömberg, Tomas; Larsson, Marcus
2018-02-01
We present a first evaluation of a new multi-exposure laser speckle contrast imaging (MELSCI) system for assessing spatial variations in the microcirculatory perfusion. The MELSCI system is based on a 1000 frames per second 1-megapixel camera connected to a field programmable gate arrays (FPGA) capable of producing MELSCI data in realtime. The imaging system is evaluated against a single point laser Doppler flowmetry (LDF) system during occlusionrelease provocations of the arm in five subjects. Perfusion is calculated from MELSCI data using current state-of-the-art inverse models. The analysis displayed a good agreement between measured and modeled data, with an average error below 6%. This strongly indicates that the applied model is capable of accurately describing the MELSCI data and that the acquired data is of high quality. Comparing readings from the occlusion-release provocation showed that the MELSCI perfusion was significantly correlated (R=0.83) to the single point LDF perfusion, clearly outperforming perfusion estimations based on a single exposure time. We conclude that the MELSCI system provides blood flow images of enhanced quality, taking us one step closer to a system that accurately can monitor dynamic changes in skin perfusion over a large area in real-time.
Dyrbye, Liselotte N; Power, David V; Massie, F Stanford; Eacker, Anne; Harper, William; Thomas, Matthew R; Szydlo, Daniel W; Sloan, Jeff A; Shanafelt, Tait D
2010-10-01
Burnout is prevalent among medical students and is a predictor of subsequent serious consideration of dropping out of medical school and suicide ideation. Understanding of the factors that protect against burnout is needed to guide student wellness programmes. A total of 1321 medical students attending five institutions were studied longitudinally (2006-2007). The surveys included standardised instruments to evaluate burnout, quality of life, fatigue and stress. Additional items explored social support, learning climate, life events, employment status and demographics. Students who did not have burnout at either time-point (resilient students) were compared with those who indicated burnout at one or both time-points (vulnerable students) using a Wilcoxon-Mann-Whitney test or Fisher's exact test. Similarly, the differences between those who recovered and those who were chronically burned out were also compared in students with burnout at the first time-point. Logistic regression modelling was employed to evaluate associations between the independent variables and resiliency to and recovery from burnout. Overall, 792 (60.0%) students completed the burnout inventory at both time-points. No differences in demographic characteristics were observed between resilient (290/792 [36.6%]) and vulnerable (502/792 [63.4%]) students. Resilient students were less likely to experience depression, had a higher quality of life, were less likely to be employed, had experienced fewer stressful life events, reported higher levels of social support, perceived their learning climate more positively and experienced less stress and fatigue (all p < 0.05) than vulnerable students. On multivariable analysis, perceiving student education as a priority for faculty staff, experiencing less stress, not being employed and being a minority were factors independently associated with recovery from burnout. Modifiable individual factors and learning climate characteristics including employment status, stress level and perceptions of the prioritising of student education by faculty members relate to medical students' vulnerability to burnout. © Blackwell Publishing Ltd 2010.
Predictors of outcomes of psychological treatments for disordered gambling: A systematic review.
Merkouris, S S; Thomas, S A; Browning, C J; Dowling, N A
2016-08-01
This systematic review aimed to synthesise the evidence relating to pre-treatment predictors of gambling outcomes following psychological treatment for disordered gambling across multiple time-points (i.e., post-treatment, short-term, medium-term, and long-term). A systematic search from 1990 to 2016 identified 50 articles, from which 11 socio-demographic, 16 gambling-related, 21 psychological/psychosocial, 12 treatment, and no therapist-related variables, were identified. Male gender and low depression levels were the most consistent predictors of successful treatment outcomes across multiple time-points. Likely predictors of successful treatment outcomes also included older age, lower gambling symptom severity, lower levels of gambling behaviours and alcohol use, and higher treatment session attendance. Significant associations, at a minimum of one time-point, were identified between successful treatment outcomes and being employed, ethnicity, no gambling debt, personality traits and being in the action stage of change. Mixed results were identified for treatment goal, while education, income, preferred gambling activity, problem gambling duration, anxiety, any psychiatric comorbidity, psychological distress, substance use, prior gambling treatment and medication use were not significantly associated with treatment outcomes at any time-point. Further research involving consistent treatment outcome frameworks, examination of treatment and therapist predictor variables, and evaluation of predictors across long-term follow-ups is warranted to advance this developing field of research. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Song, Ji Soo; Kwak, Hyo Sung; Byon, Jung Hee; Jin, Gong Yong
2017-05-01
To compare the apparent diffusion coefficient (ADC) of upper abdominal organs acquired at different time points, and to investigate the usefulness of normalization. We retrospectively evaluated 58 patients who underwent three rounds of magnetic resonance (MR) imaging including diffusion-weighted imaging of the upper abdomen. MR examinations were performed using three different 3.0 Tesla (T) and one 1.5T systems, with variable b value combinations and respiratory motion compensation techniques. The ADC values of the upper abdominal organs from three different time points were analyzed, using the ADC values of the paraspinal muscle (ADC psm ) and spleen (ADC spleen ) for normalization. Intraclass correlation coefficients (ICC) and comparison of dependent ICCs were used for statistical analysis. The ICCs of the original ADC and ADC psm showed fair to substantial agreement, while ADC spleen showed substantial to almost perfect agreement. The ICC of ADC spleen of all anatomical regions showed less variability compared with that of the original ADC (P < 0.005). Normalized ADC using the spleen as a reference organ significantly decreased variability in measurement of the upper abdominal organs in different MR systems at different time points and could be regarded as an imaging biomarker for future multicenter, longitudinal studies. 5 J. MAGN. RESON. IMAGING 2017;45:1494-1501. © 2016 International Society for Magnetic Resonance in Medicine.
Weatherly, B H; Griffin, D B; Johnson, H K; Walter, J P; De La Zerda, M J; Tipton, N C; Savell, J W
2001-12-01
Selected beef subprimals were obtained from fabrication lines of three foodservice purveyors to assist in the development of a software support program for the beef foodservice industry. Subprimals were fabricated into bone-in or boneless foodservice ready-to-cook portion-sized cuts and associated components by professional meat cutters. Each subprimal was cut to generate mean foodservice cutting yields and labor requirements, which were calculated from observed weights (kilograms) and processing times (seconds). Once fabrication was completed, data were analyzed to determine means and standard errors of percentage yields and processing times for each subprimal. Subprimals cut to only one end point were evaluated for mean foodservice yields and processing times, but no comparisons were made within subprimal. However, those traditionally cut into various end points were additionally compared by cutting style. Subprimals cut by a single cutting style included rib, roast-ready; ribeye roll, lip-on, bone-in; brisket, deckle-off, boneless; top (inside) round; and bottom sirloin butt, flap, boneless. Subprimals cut into multiple end points or styles included ribeye, lip-on; top sirloin, cap; tenderloin butt, defatted; shortloin, short-cut; strip loin, boneless; top sirloin butt, boneless; and tenderloin, full, side muscle on, defatted. Mean yields of portion cuts, and mean fabrication times required to manufacture these cuts differed (P < 0.05) by cutting specification of the final product. In general, as the target portion size of fabricated steaks decreased, the mean number of steaks derived from any given subprimal cut increased, causing total foodservice yield to decrease and total processing time to increase. Therefore, an inverse relationship tended to exist between processing times and foodservice yields. With a method of accurately evaluating various beef purchase options, such as traditional commodity subprimals, closely trimmed subprimals, and pre-cut portion steaks in terms of yield and labor cost, foodservice operators will be better equipped to decide what option is more viable for their operation.
Katragadda, Suresh; Jain, Ritesh; Kwatra, Deep; Hariharan, Sudharshan; Mitra, Ashim K.
2008-01-01
In vivo systemic absorption of the amino acid prodrugs of acyclovir (ACV) after oral administration was evaluated in rats. Stability of the prodrugs, L-Alanine-ACV (AACV), L-Serine-ACV (SACV), L-Isoleucine-ACV (IACV), γ-Glutamate-ACV (EACV) and L-Valine-ACV (VACV) was evaluated in various tissues. Interaction of these prodrugs with the transporters on Caco-2 cells was studied. In vivo systemic bioavailability of these prodrugs upon oral administration was evaluated in jugular vein cannulated rats. The amino acid ester prodrugs showed affinity towards various amino acid transporters as well as the peptide transporter on the Caco-2 cells. In terms of stability, EACV was most enzymatically stable compared to other prodrugs especially in liver homogenate. In oral absorption studies, ACV and AACV showed high terminal elimination rate constants (λz). SACV and VACV exhibited approximately five fold increase in area under the curve (AUC) values relative to ACV (p<0.05). Cmax(T) (maximum concentration) of SACV was observed to be 39 ± 22 µM in plasma which is 2 times better than VACV and 15 times better than ACV. Clast(T) (concentration at the last time point) of SACV was observed to be 0.18 ± 0.06 µM in plasma which is 2 times better than VACV and 3 times better than ACV. Amino acid ester prodrugs of ACV were absorbed at varying amounts (Cmax) and eliminated at varying rates (λz) thereby leading to varying extents (AUC). The amino acid ester prodrug SACV owing to its enhanced stability, higher AUC and better concentration at last time point seems to be a promising candidate for the oral treatment of herpes infections. PMID:18638532
Can prospect theory explain risk-seeking behavior by terminally ill patients?
Rasiel, Emma B; Weinfurt, Kevin P; Schulman, Kevin A
2005-01-01
Patients with life-threatening conditions sometimes appear to make risky treatment decisions as their condition declines, contradicting the risk-averse behavior predicted by expected utility theory. Prospect theory accommodates such decisions by describing how individuals evaluate outcomes relative to a reference point and how they exhibit risk-seeking behavior over losses relative to that point. The authors show that a patient's reference point for his or her health is a key factor in determining which treatment option the patient selects, and they examine under what circumstances the more risky option is selected. The authors argue that patients' reference points may take time to adjust following a change in diagnosis, with implications for predicting under what circumstances a patient may select experimental or conventional therapies or select no treatment.
Variability within Systemic In Vivo Toxicity Studies (ASCCT)
In vivo studies have long been considered the gold standard for toxicology screening. Often time models developed in silico and/or using in vitro data to estimate points of departures (POD) are compared to the in vivo data to benchmark and evaluate quality and goodness of fit. ...
Characteristics of Outstanding Student Teachers
ERIC Educational Resources Information Center
Eldar, Eitan; Talmor, Rachel
2006-01-01
This paper describes the characteristics of student teachers who were evaluated as outstanding during their teacher education studies. Outstanding students were selected after 2 years of field experiences based on their teaching abilities and academic achievements. Data were collected at three points of time: before they commenced their studies at…
Evaluation of crumb rubber in hot mix asphalt.
DOT National Transportation Integrated Search
2004-07-01
An asphalt-rubber hot mix asphalt (AR-HMA) design was created using a Superpave 12.5mm gradation and a #30 (-) mesh : crumb rubber at 20% total weight of the asphalt binder. At this point in time, asphalt rubber has only been used with HMA : that con...
Chacón, Jose
2010-07-21
Drug efficacy might differ from clinical trial results when performed in clinical daily conditions. Therefore, it is mandatory to conduct trials about effectiveness to improve external validity. This post-authorization, open-label, noncontrolled, prospective, multicenter, observational, and naturalistic trial was designed to search for factors influencing the racecadotril overall effect on childhood acute watery diarrhea in a real-world setting of Venezuela. There were 3,873 children with acute watery diarrhea treated with racecadotril, an enkephalin breakdown blocker plus oral rehydration therapy by 97 pediatricians. Evaluations were carried out daily until emission of two consecutive formed stools or absence of watery bowel movements for 24 hours. The primary end-point was time-to-relief, defined as the time from first racecadotril dose to the last watery bowel movement time. Age, gender, nursing type, nursing status during diarrhea, diarrhea severity, and co-medication were considered as factors in the statistical analysis. The primary end-point was evaluated by factors using UNIANOVA, and post-hoc tests were done. A multiple regression analysis was carried out to identify factors affecting drug performance, racecadotril effectiveness and tolerability overall assessment was searched by physicians and patients, and inter-observer agreement was evaluated by kappa statistics. The mean time-to-relief was 18.5 +/- 12.5 hours [95% confidence interval 17.9-19.0] and the diarrhea severity was the only variable with significant and independent weight on racecadotril effectiveness explaining 23% of time-to-relief variance, but even in severe diarrhea cases this time was less than 24 hours. High agreement about satisfactory perception on effectiveness and tolerability was reached among physicians and patients. In conclusion, the racecadotril overall effect, evaluated in a real-world setting of Venezuela, was in agreement with results of some earlier controlled trials. It was only influenced by severity of diarrhea episode, as well as being considered an effective and well tolerated treatment by physicians and patients.
Kastner, Monika; Sawka, Anna; Thorpe, Kevin; Chignel, Mark; Marquez, Christine; Newton, David; Straus, Sharon E
2011-07-22
Osteoporosis affects over 200 million people worldwide at a high cost to healthcare systems. Although guidelines on assessing and managing osteoporosis are available, many patients are not receiving appropriate diagnostic testing or treatment. Findings from a systematic review of osteoporosis interventions, a series of mixed-methods studies, and advice from experts in osteoporosis and human-factors engineering were used collectively to develop a multicomponent tool (targeted to family physicians and patients at risk for osteoporosis) that may support clinical decision making in osteoporosis disease management at the point of care. A three-phased approach will be used to evaluate the osteoporosis tool. In phase 1, the tool will be implemented in three family practices. It will involve ensuring optimal functioning of the tool while minimizing disruption to usual practice. In phase 2, the tool will be pilot tested in a quasi-experimental interrupted time series (ITS) design to determine if it can improve osteoporosis disease management at the point of care. Phase 3 will involve conducting a qualitative postintervention follow-up study to better understand participants' experiences and perceived utility of the tool and readiness to adopt the tool at the point of care. The osteoporosis tool has the potential to make several contributions to the development and evaluation of complex, chronic disease interventions, such as the inclusion of an implementation strategy prior to conducting an evaluation study. Anticipated benefits of the tool may be to increase awareness for patients about osteoporosis and its associated risks and provide an opportunity to discuss a management plan with their physician, which may all facilitate patient self-management.
2011-01-01
Background Osteoporosis affects over 200 million people worldwide at a high cost to healthcare systems. Although guidelines on assessing and managing osteoporosis are available, many patients are not receiving appropriate diagnostic testing or treatment. Findings from a systematic review of osteoporosis interventions, a series of mixed-methods studies, and advice from experts in osteoporosis and human-factors engineering were used collectively to develop a multicomponent tool (targeted to family physicians and patients at risk for osteoporosis) that may support clinical decision making in osteoporosis disease management at the point of care. Methods A three-phased approach will be used to evaluate the osteoporosis tool. In phase 1, the tool will be implemented in three family practices. It will involve ensuring optimal functioning of the tool while minimizing disruption to usual practice. In phase 2, the tool will be pilot tested in a quasi-experimental interrupted time series (ITS) design to determine if it can improve osteoporosis disease management at the point of care. Phase 3 will involve conducting a qualitative postintervention follow-up study to better understand participants' experiences and perceived utility of the tool and readiness to adopt the tool at the point of care. Discussion The osteoporosis tool has the potential to make several contributions to the development and evaluation of complex, chronic disease interventions, such as the inclusion of an implementation strategy prior to conducting an evaluation study. Anticipated benefits of the tool may be to increase awareness for patients about osteoporosis and its associated risks and provide an opportunity to discuss a management plan with their physician, which may all facilitate patient self-management. PMID:21781318
NASA Astrophysics Data System (ADS)
Javadi, Maryam; Shahrabi, Jamal
2014-03-01
The problems of facility location and the allocation of demand points to facilities are crucial research issues in spatial data analysis and urban planning. It is very important for an organization or governments to best locate its resources and facilities and efficiently manage resources to ensure that all demand points are covered and all the needs are met. Most of the recent studies, which focused on solving facility location problems by performing spatial clustering, have used the Euclidean distance between two points as the dissimilarity function. Natural obstacles, such as mountains and rivers, can have drastic impacts on the distance that needs to be traveled between two geographical locations. While calculating the distance between various supply chain entities (including facilities and demand points), it is necessary to take such obstacles into account to obtain better and more realistic results regarding location-allocation. In this article, new models were presented for location of urban facilities while considering geographical obstacles at the same time. In these models, three new distance functions were proposed. The first function was based on the analysis of shortest path in linear network, which was called SPD function. The other two functions, namely PD and P2D, were based on the algorithms that deal with robot geometry and route-based robot navigation in the presence of obstacles. The models were implemented in ArcGIS Desktop 9.2 software using the visual basic programming language. These models were evaluated using synthetic and real data sets. The overall performance was evaluated based on the sum of distance from demand points to their corresponding facilities. Because of the distance between the demand points and facilities becoming more realistic in the proposed functions, results indicated desired quality of the proposed models in terms of quality of allocating points to centers and logistic cost. Obtained results show promising improvements of the allocation, the logistics costs and the response time. It can also be inferred from this study that the P2D-based model and the SPD-based model yield similar results in terms of the facility location and the demand allocation. It is noted that the P2D-based model showed better execution time than the SPD-based model. Considering logistic costs, facility location and response time, the P2D-based model was appropriate choice for urban facility location problem considering the geographical obstacles.
Greenhill, Laurence L.; Nordbrock, Earl; Connor, Daniel F.; Kollins, Scott H.; Adjei, Akwete; Childress, Ann; Stehli, Annamarie; Kupper, Robert J.
2014-01-01
Abstract Objective: The purpose of this study was to assess the time of onset and time course of efficacy over 12.0 hours of extended-release multilayer bead formulation of methylphenidate (MPH-MLR) compared with placebo in children 6–12 years of age with attention-deficit/hyperactivity disorder (ADHD) in a laboratory school setting. Methods: This randomized double-blind placebo-controlled study included children 6–12 years of age with ADHD. Enrolled children went through four study phases: 1) Screening period (≤4 weeks) and a 2 day medication washout period; 2) open-label period with dose initiation of MPH-MLR 15 mg daily and individual dose optimization treatment period (2–4 weeks); 3) double-blind crossover period in which participants were randomized to sequences (1 week each) of placebo and the optimized MPH-MLR dose given daily; and 4) follow-up safety call. Analog classroom time course evaluations were performed at the end of each double-blind week. The primary efficacy end-point was the mean of the on-treatment/postdose Swanson, Kotkin, Agler, M-Flynn, and Pelham (SKAMP)-Total scores over time points collected 1.0–12.0 hours after dosing. End-points were evaluated using a mixed-effects analysis of covariance. Results: The evaluable population included 20 participants. The least-squares mean postdose SKAMP-Total score was higher for placebo than for MPH-MLR (2.18 vs. 1.32, respectively; p=0.0001), indicating fewer symptoms with MPH-MLR therapy than with placebo. No difference in SKAMP-Total score between participants who received sequence 1 or sequence 2 was noted. From each of hours 1.0–12.0, least-squares mean SKAMP-Total score was significantly lower for those receiving MPH-MLR than for those receiving placebo (p≤0.0261). Neither serious adverse events nor new or unexpected safety findings were noted during the study. Conclusions: MPH-MLR showed a significant decrease in SKAMP scores compared with placebo in children with ADHD 6–12 years of age, indicating a decrease in ADHD symptoms. The estimated onset was observed within 1.0 hour, and duration was measured to 12.0 hours postdose. Trial registration: ClinicalTrials.gov Identifier: NCT01269463 PMID:25470572
Interpreting the handling qualities of aircraft with stability and control augmentation
NASA Technical Reports Server (NTRS)
Hodgkinson, J.; Potsdam, E. H.; Smith, R. E.
1990-01-01
The general process of designing an aircraft for good flying qualities is first discussed. Lessons learned are pointed out, with piloted evaluation emerging as a crucial element. Two sources of rating variability in performing these evaluations are then discussed. First, the finite endpoints of the Cooper-Harper scale do not bias parametric statistical analyses unduly. Second, the wording of the scale does introduce some scatter. Phase lags generated by augmentation systems, as represented by equivalent time delays, often cause poor flying qualities. An analysis is introduced which allows a designer to relate any level of time delay to a probability of loss of aircraft control. This view of time delays should, it is hoped, allow better visibility of the time delays in the design process.
Stein, Marjorie W; Frank, Susan J; Roberts, Jeffrey H; Finkelstein, Malka; Heo, Moonseong
2016-05-01
The aim of this study was to determine whether group-based or didactic teaching is more effective to teach ACR Appropriateness Criteria to medical students. An identical pretest, posttest, and delayed multiple-choice test was used to evaluate the efficacy of the two teaching methods. Descriptive statistics comparing test scores were obtained. On the posttest, the didactic group gained 12.5 points (P < .0001), and the group-based learning students gained 16.3 points (P < .0001). On the delayed test, the didactic group gained 14.4 points (P < .0001), and the group-based learning students gained 11.8 points (P < .001). The gains in scores on both tests were statistically significant for both groups. However, the differences in scores were not statistically significant comparing the two educational methods. Compared with didactic lectures, group-based learning is more enjoyable, time efficient, and equally efficacious. The choice of educational method can be individualized for each institution on the basis of group size, time constraints, and faculty availability. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Anchukaitis, Kevin J.; Wilson, Rob; Briffa, Keith R.; Büntgen, Ulf; Cook, Edward R.; D'Arrigo, Rosanne; Davi, Nicole; Esper, Jan; Frank, David; Gunnarson, Björn E.; Hegerl, Gabi; Helama, Samuli; Klesse, Stefan; Krusic, Paul J.; Linderholm, Hans W.; Myglan, Vladimir; Osborn, Timothy J.; Zhang, Peng; Rydval, Milos; Schneider, Lea; Schurer, Andrew; Wiles, Greg; Zorita, Eduardo
2017-05-01
Climate field reconstructions from networks of tree-ring proxy data can be used to characterize regional-scale climate changes, reveal spatial anomaly patterns associated with atmospheric circulation changes, radiative forcing, and large-scale modes of ocean-atmosphere variability, and provide spatiotemporal targets for climate model comparison and evaluation. Here we use a multiproxy network of tree-ring chronologies to reconstruct spatially resolved warm season (May-August) mean temperatures across the extratropical Northern Hemisphere (40-90°N) using Point-by-Point Regression (PPR). The resulting annual maps of temperature anomalies (750-1988 CE) reveal a consistent imprint of volcanism, with 96% of reconstructed grid points experiencing colder conditions following eruptions. Solar influences are detected at the bicentennial (de Vries) frequency, although at other time scales the influence of insolation variability is weak. Approximately 90% of reconstructed grid points show warmer temperatures during the Medieval Climate Anomaly when compared to the Little Ice Age, although the magnitude varies spatially across the hemisphere. Estimates of field reconstruction skill through time and over space can guide future temporal extension and spatial expansion of the proxy network.
Evaluation of Fiber Bragg Grating and Distributed Optical Fiber Temperature Sensors
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCary, Kelly Marie
Fiber optic temperature sensors were evaluated in the High Temperature Test Lab (HTTL) to determine the accuracy of the measurements at various temperatures. A distributed temperature sensor was evaluated up to 550C and a fiber Bragg grating sensor was evaluated up to 750C. HTTL measurements indicate that there is a drift in fiber Bragg sensor over time of approximately -10C with higher accuracy at temperatures above 300C. The distributed sensor produced some bad data points at and above 500C but produced measurements with less than 2% error at increasing temperatures up to 400C
IgV gene intraclonal diversification and clonal evolution in B-cell chronic lymphocytic leukaemia.
Bagnara, Davide; Callea, Vincenzo; Stelitano, Caterina; Morabito, Fortunato; Fabris, Sonia; Neri, Antonino; Zanardi, Sabrina; Ghiotto, Fabio; Ciccone, Ermanno; Grossi, Carlo Enrico; Fais, Franco
2006-04-01
Intraclonal diversification of immunoglobulin (Ig) variable (V) genes was evaluated in leukaemic cells from a B-cell chronic lymphocytic leukaemia (B-CLL) case over a 2-year period at four time points. Intraclonal heterogeneity was analysed by sequencing 305 molecular clones derived from polymerase chain reaction amplification of B-CLL cell IgV heavy (H) and light (C) chain gene rearrangements. Sequences were compared with evaluating intraclonal variation and the nature of somatic mutations. Although IgV intraclonal variation was detected at all time points, its level decreased with time and a parallel emergence of two more represented V(H)DJ(H) clones was observed. They differed by nine nucleotide substitutions one of which only caused a conservative replacement aminoacid change. In addition, one V(L)J(L) rearrangement became more represented over time. Analyses of somatic mutations suggest antigen selection and impairment of negative selection of neoplastic cells. In addition, a genealogical tree representing a model of clonal evolution of the neoplastic cells was created. It is of note that, during the period of study, the patient showed clinical progression of disease. We conclude that antigen stimulation and somatic hypermutation may participate in disease progression through the selection and expansion of neoplastic subclone(s).
Markovic, Gabriela; Schult, Marie-Louise; Bartfai, Aniko; Elg, Mattias
2017-01-31
Progress in early cognitive recovery after acquired brain injury is uneven and unpredictable, and thus the evaluation of rehabilitation is complex. The use of time-series measurements is susceptible to statistical change due to process variation. To evaluate the feasibility of using a time-series method, statistical process control, in early cognitive rehabilitation. Participants were 27 patients with acquired brain injury undergoing interdisciplinary rehabilitation of attention within 4 months post-injury. The outcome measure, the Paced Auditory Serial Addition Test, was analysed using statistical process control. Statistical process control identifies if and when change occurs in the process according to 3 patterns: rapid, steady or stationary performers. The statistical process control method was adjusted, in terms of constructing the baseline and the total number of measurement points, in order to measure a process in change. Statistical process control methodology is feasible for use in early cognitive rehabilitation, since it provides information about change in a process, thus enabling adjustment of the individual treatment response. Together with the results indicating discernible subgroups that respond differently to rehabilitation, statistical process control could be a valid tool in clinical decision-making. This study is a starting-point in understanding the rehabilitation process using a real-time-measurements approach.
2011-10-01
those least likely to change significantly over time: upper ridges of the eye sockets, areas around the cheekbones, sides of the mouth , nose shape, and...conduct self-process using their electronic passports. ACS processes roughly 22 million visitors annually in airport environments. The program was...the electronic passport. A successful match permits a traveler to clear through the customs control point, whereas an unsuccessful match alerts the
Metal Vapor Arcing Risk Assessment Tool
NASA Technical Reports Server (NTRS)
Hill, Monika C.; Leidecker, Henning W.
2010-01-01
The Tin Whisker Metal Vapor Arcing Risk Assessment Tool has been designed to evaluate the risk of metal vapor arcing and to help facilitate a decision toward a researched risk disposition. Users can evaluate a system without having to open up the hardware. This process allows for investigating components at risk rather than spending time and money analyzing every component. The tool points to a risk level and provides direction for appropriate action and documentation.
Applications of the gambling score in evaluating earthquake predictions and forecasts
NASA Astrophysics Data System (ADS)
Zhuang, Jiancang; Zechar, Jeremy D.; Jiang, Changsheng; Console, Rodolfo; Murru, Maura; Falcone, Giuseppe
2010-05-01
This study presents a new method, namely the gambling score, for scoring the performance earthquake forecasts or predictions. Unlike most other scoring procedures that require a regular scheme of forecast and treat each earthquake equally, regardless their magnitude, this new scoring method compensates the risk that the forecaster has taken. Starting with a certain number of reputation points, once a forecaster makes a prediction or forecast, he is assumed to have betted some points of his reputation. The reference model, which plays the role of the house, determines how many reputation points the forecaster can gain if he succeeds, according to a fair rule, and also takes away the reputation points bet by the forecaster if he loses. This method is also extended to the continuous case of point process models, where the reputation points betted by the forecaster become a continuous mass on the space-time-magnitude range of interest. For discrete predictions, we apply this method to evaluate performance of Shebalin's predictions made by using the Reverse Tracing of Precursors (RTP) algorithm and of the outputs of the predictions from the Annual Consultation Meeting on Earthquake Tendency held by China Earthquake Administration. For the continuous case, we use it to compare the probability forecasts of seismicity in the Abruzzo region before and after the L'aquila earthquake based on the ETAS model and the PPE model.
Evaluating Diagnostic Point-of-Care Tests in Resource-Limited Settings
Drain, Paul K; Hyle, Emily P; Noubary, Farzad; Freedberg, Kenneth A; Wilson, Douglas; Bishai, William; Rodriguez, William; Bassett, Ingrid V
2014-01-01
Diagnostic point-of-care (POC) testing is intended to minimize the time to obtain a test result, thereby allowing clinicians and patients to make an expeditious clinical decision. As POC tests expand into resource-limited settings (RLS), the benefits must outweigh the costs. To optimize POC testing in RLS, diagnostic POC tests need rigorous evaluations focused on relevant clinical outcomes and operational costs, which differ from evaluations of conventional diagnostic tests. Here, we reviewed published studies on POC testing in RLS, and found no clearly defined metric for the clinical utility of POC testing. Therefore, we propose a framework for evaluating POC tests, and suggest and define the term “test efficacy” to describe a diagnostic test’s capacity to support a clinical decision within its operational context. We also proposed revised criteria for an ideal diagnostic POC test in resource-limited settings. Through systematic evaluations, comparisons between centralized diagnostic testing and novel POC technologies can be more formalized, and health officials can better determine which POC technologies represent valuable additions to their clinical programs. PMID:24332389
Advanced Communication Technology Satellite (ACTS) Multibeam Antenna On-Orbit Performance
NASA Technical Reports Server (NTRS)
1995-01-01
The NASA Lewis Research Center's Advanced Communication Technology Satellite (ACTS) was launched in September 1993. ACTS introduced several new technologies, including a multibeam antenna (MBA) operating at extremely short wavelengths never before used in communications. This antenna, which has both fixed and rapidly reconfigurable high-energy spot beams (150 miles in diameter), serves users equipped with small antenna terminals. Extensive structural and thermal analyses have been performed for simulating the ACTS MBA on-orbit performance. The results show that the reflector surfaces (mainly the front subreflector), antenna support assembly, and metallic surfaces on the spacecraft body will be distorted because of the thermal effects of varying solar heating, which degrade the ACTS MBA performance. Since ACTS was launched, a number of evaluations have been performed to assess MBA performance in the space environment. For example, the on-orbit performance measurements found systematic environmental disturbances to the MBA beam pointing. These disturbances were found to be imposed by the attitude control system, antenna and spacecraft mechanical alignments, and on-orbit thermal effects. As a result, the MBA may not always exactly cover the intended service area. In addition, the on-orbit measurements showed that antenna pointing accuracy is the performance parameter most sensitive to thermal distortions on the front subreflector surface and antenna support assemblies. Several compensation approaches were tested and evaluated to restore on-orbit pointing stability. A combination of autotrack (75 percent of the time) and Earth sensor control (25 percent of the time) was found to be the best way to compensate for antenna pointing error during orbit. This approach greatly minimizes the effects of thermal distortions on antenna beam pointing.
Actigraphy--a useful tool for motor activity monitoring in stroke patients.
Reiterer, Veronika; Sauter, Cornelia; Klösch, Gerhard; Lalouschek, Wolfgang; Zeitlhofer, Josef
2008-01-01
The aim of the present study was the evaluation of actigraphy as a tool to objectify the recovery process after motor paresis due to stroke. The motor activity of both arms of patients suffering from stroke was actigraphically recorded at four different time points during the course of rehabilitation: 24-36 h, 5-7 days, 3 months, and 6 months after stroke. Motor activity monitored by wrist-worn actigraphs located at the impaired side revealed an increase in activity between the first two time points and the subsequent ones. Additionally, actigraphic recordings showed lower total motor activity at the impaired side as compared to the nonimpaired side. A significant positive correlation was found between the actigraphically recorded motor activity and the results of the Scandinavian Stroke scale, the Barthel Index, the Rankin Scale Score and with the Motoricity Index during the 1st week, which corresponds to the time when neurological deficits were most pronounced. Our results suggest that actigraphy is a useful tool in the objective evaluation of motor activity after stroke. Moreover, actigraphy covers additional aspects that are not reflected by the usual stroke scales in a clinical situation. Copyright 2008 S. Karger AG, Basel.
Accuracy assessment of minimum control points for UAV photography and georeferencing
NASA Astrophysics Data System (ADS)
Skarlatos, D.; Procopiou, E.; Stavrou, G.; Gregoriou, M.
2013-08-01
In recent years, Autonomous Unmanned Aerial Vehicles (AUAV) became popular among researchers across disciplines because they combine many advantages. One major application is monitoring and mapping. Their ability to fly beyond eye sight autonomously, collecting data over large areas whenever, wherever, makes them excellent platform for monitoring hazardous areas or disasters. In both cases rapid mapping is needed while human access isn't always a given. Indeed, current automatic processing of aerial photos using photogrammetry and computer vision algorithms allows for rapid orthophomap production and Digital Surface Model (DSM) generation, as tools for monitoring and damage assessment. In such cases, control point measurement using GPS is either impossible, or time consuming or costly. This work investigates accuracies that can be attained using few or none control points over areas of one square kilometer, in two test sites; a typical block and a corridor survey. On board GPS data logged during AUAV's flight are being used for direct georeferencing, while ground check points are being used for evaluation. In addition various control point layouts are being tested using bundle adjustment for accuracy evaluation. Results indicate that it is possible to use on board single frequency GPS for direct georeferencing in cases of disaster management or areas without easy access, or even over featureless areas. Due to large numbers of tie points in the bundle adjustment, horizontal accuracy can be fulfilled with a rather small number of control points, but vertical accuracy may not.
Efficacy of Several Therapeutic Agents in a Murine Model of Dry Eye Syndrome
Kilic, Servet; Kulualp, Kadri
2016-01-01
In the current study, we used 56 female BALB/c mice with induced dry eye syndrome to evaluate the therapeutic effects of formal saline (FS), sodium hyaluronate (SH), diclofenac sodium (DS), olopatadine (OP), retinoic acid (RA), fluoromethanole (FML), cyclosporine A (CsA), and doxycycline hyclate (DH). All subjects were kept in an evaporative ‘dry eye cabinet’ for the assessment of blink rate, tear production, tear break-up time, and impression cytology prior to (baseline) and during weeks 2, 4, and 6 of the study. The right eyes of all subjects were treated topically with 5 µL of the test agent twice daily during weeks 2 through 6. Impression cytology and tear break-up time differed between time points in all groups and differed between groups at weeks 4 and 6. Blink rate differed by time point only in the FS, FML, and DH groups. Tear production according to the phenol red cotton thread test differed by time point for all groups except RA, CsA, and DH and differed between groups only at week 6. Among the compounds tested in the present study, DS and CsA were the most effective therapeutic agents in our mouse model of dry eye syndrome; these agents likely exert their therapeutic effect through their antiinflammatory activity. PMID:27053565
Lucero, María Luisa; Patterson, Andrew B
2012-06-01
This study evaluated the tissue distribution of total radioactivity in male albino, male pigmented, and time-mated female albino rats after oral administration of a single dose of [¹⁴C]-bilastine (20 mg/kg). Although only 1 animal was analyzed at each time point, there were apparent differences in bilastine distribution. Radioactivity was distributed to only a few tissues at low levels in male rats, whereas distribution was more extensive and at higher levels in female rats. This may be a simple sex-related difference. In each group and at each time point, concentrations of radioactivity were high in the liver and kidney, reflecting the role of these organs in the elimination process. In male albino rats, no radioactivity was measurable by 72 hours postdose. In male pigmented rats, only the eye and uveal tract had measurable levels of radioactivity at 24 hours. Measureable levels of radioactivity were retained in these tissues at the final sampling time point (336 hours postdose), indicating a degree of melanin-associated binding. In time-mated female rats, but not in albino or pigmented male rats, there was evidence of low-level passage of radioactivity across the placental barrier into fetal tissues as well as low-level transfer of radioactivity into the brain.
NASA Astrophysics Data System (ADS)
Fukushima, Toshio
2012-04-01
By extending the exponent of floating point numbers with an additional integer as the power index of a large radix, we compute fully normalized associated Legendre functions (ALF) by recursion without underflow problem. The new method enables us to evaluate ALFs of extremely high degree as 232 = 4,294,967,296, which corresponds to around 1 cm resolution on the Earth's surface. By limiting the application of exponent extension to a few working variables in the recursion, choosing a suitable large power of 2 as the radix, and embedding the contents of the basic arithmetic procedure of floating point numbers with the exponent extension directly in the program computing the recurrence formulas, we achieve the evaluation of ALFs in the double-precision environment at the cost of around 10% increase in computational time per single ALF. This formulation realizes meaningful execution of the spherical harmonic synthesis and/or analysis of arbitrary degree and order.
LANDSAT-4 MSS Geometric Correction: Methods and Results
NASA Technical Reports Server (NTRS)
Brooks, J.; Kimmer, E.; Su, J.
1984-01-01
An automated image registration system such as that developed for LANDSAT-4 can produce all of the information needed to verify and calibrate the software and to evaluate system performance. The on-line MSS archive generation process which upgrades systematic correction data to geodetic correction data is described as well as the control point library build subsystem which generates control point chips and support data for on-line upgrade of correction data. The system performance was evaluated for both temporal and geodetic registration. For temporal registration, 90% errors were computed to be .36 IFOV (instantaneous field of view) = 82.7 meters) cross track, and .29 IFOV along track. Also, for actual production runs monitored, the 90% errors were .29 IFOV cross track and .25 IFOV along track. The system specification is .3 IFOV, 90% of the time, both cross and along track. For geodetic registration performance, the model bias was measured by designating control points in the geodetically corrected imagery.
NASA Technical Reports Server (NTRS)
Arkin, C. Richard; Ottens, Andrew K.; Diaz, Jorge A.; Griffin, Timothy P.; Follestein, Duke; Adams, Fredrick; Steinrock, T. (Technical Monitor)
2001-01-01
For Space Shuttle launch safety, there is a need to monitor the concentration Of H2, He, O2, and Ar around the launch vehicle. Currently a large mass spectrometry system performs this task, using long transport lines to draw in samples. There is great interest in replacing this stationary system with several miniature, portable, rugged mass spectrometers which act as point sensors which can be placed at the sampling point. Five commercial and two non-commercial analyzers are evaluated. The five commercial systems include the Leybold Inficon XPR-2 linear quadrupole, the Stanford Research (SRS-100) linear quadrupole, the Ferran linear quadrupole array, the ThermoQuest Polaris-Q quadrupole ion trap, and the IonWerks Time-of-Flight (TOF). The non-commercial systems include a compact double focusing sector (CDFMS) developed at the University of Minnesota, and a quadrupole ion trap (UF-IT) developed at the University of Florida.
Acoustic holography: Problems associated with construction and reconstruction techniques
NASA Technical Reports Server (NTRS)
Singh, J. J.
1978-01-01
The implications of the difference between the inspecting and interrogating radiations are discussed. For real-time, distortionless, sound viewing, it is recommended that infrared radiation of wavelength comparable to the inspecting sound waves be used. The infrared images can be viewed with (IR visible) converter phosphors. The real-time display of the visible image of the acoustically-inspected object at low sound levels such as are used in medical diagnosis is evaluated. In this connection attention is drawn to the need for a phosphor screen which is such that its optical transmission at any point is directly related to the incident electron beam intensity at that point. Such a screen, coupled with an acoustical camera, can enable instantaneous sound wave reconstruction.
USDA-ARS?s Scientific Manuscript database
Soil moisture is an intrinsic state variable that varies considerably in space and time. From a hydrologic viewpoint, soil moisture controls runoff, infiltration, storage and drainage. Soil moisture determines the partitioning of the incoming radiation between latent and sensible heat fluxes. Althou...
Estimating Statistical Power When Making Adjustments for Multiple Tests
ERIC Educational Resources Information Center
Porter, Kristin E.
2016-01-01
In recent years, there has been increasing focus on the issue of multiple hypotheses testing in education evaluation studies. In these studies, researchers are typically interested in testing the effectiveness of an intervention on multiple outcomes, for multiple subgroups, at multiple points in time or across multiple treatment groups. When…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-28
... systems. E. Quantitative Methods for Comparing Capital Frameworks The NPR sought comment on how the... industry while assessing levels of capital. This commenter points out maintaining reliable comparative data over time could make quantitative methods for this purpose difficult. For example, evaluating asset...
Prediction and Stability of Mathematics Skill and Difficulty
ERIC Educational Resources Information Center
Martin, Rebecca B.; Cirino, Paul T.; Barnes, Marcia A.; Ewing-Cobbs, Linda; Fuchs, Lynn S.; Stuebing, Karla K.; Fletcher, Jack M.
2013-01-01
The present study evaluated the stability of math learning difficulties over a 2-year period and investigated several factors that might influence this stability (categorical vs. continuous change, liberal vs. conservative cut point, broad vs. specific math assessment); the prediction of math performance over time and by performance level was also…
Conditional heteroscedasticity as a leading indicator of ecological regime shifts.
Seekell, David A; Carpenter, Stephen R; Pace, Michael L
2011-10-01
Regime shifts are massive, often irreversible, rearrangements of nonlinear ecological processes that occur when systems pass critical transition points. Ecological regime shifts sometimes have severe consequences for human well-being, including eutrophication in lakes, desertification, and species extinctions. Theoretical and laboratory evidence suggests that statistical anomalies may be detectable leading indicators of regime shifts in ecological time series, making it possible to foresee and potentially avert incipient regime shifts. Conditional heteroscedasticity is persistent variance characteristic of time series with clustered volatility. Here, we analyze conditional heteroscedasticity as a potential leading indicator of regime shifts in ecological time series. We evaluate conditional heteroscedasticity by using ecological models with and without four types of critical transition. On approaching transition points, all time series contain significant conditional heteroscedasticity. This signal is detected hundreds of time steps in advance of the regime shift. Time series without regime shifts do not have significant conditional heteroscedasticity. Because probability values are easily associated with tests for conditional heteroscedasticity, detection of false positives in time series without regime shifts is minimized. This property reduces the need for a reference system to compare with the perturbed system.
NASA Technical Reports Server (NTRS)
Gupta, R. N.; Moss, J. N.; Simmonds, A. L.
1982-01-01
Two flow-field codes employing the time- and space-marching numerical techniques were evaluated. Both methods were used to analyze the flow field around a massively blown Jupiter entry probe under perfect-gas conditions. In order to obtain a direct point-by-point comparison, the computations were made by using identical grids and turbulence models. For the same degree of accuracy, the space-marching scheme takes much less time as compared to the time-marching method and would appear to provide accurate results for the problems with nonequilibrium chemistry, free from the effect of local differences in time on the final solution which is inherent in time-marching methods. With the time-marching method, however, the solutions are obtainable for the realistic entry probe shapes with massive or uniform surface blowing rates; whereas, with the space-marching technique, it is difficult to obtain converged solutions for such flow conditions. The choice of the numerical method is, therefore, problem dependent. Both methods give equally good results for the cases where results are compared with experimental data.
Reverse engineering gene regulatory networks from measurement with missing values.
Ogundijo, Oyetunji E; Elmas, Abdulkadir; Wang, Xiaodong
2016-12-01
Gene expression time series data are usually in the form of high-dimensional arrays. Unfortunately, the data may sometimes contain missing values: for either the expression values of some genes at some time points or the entire expression values of a single time point or some sets of consecutive time points. This significantly affects the performance of many algorithms for gene expression analysis that take as an input, the complete matrix of gene expression measurement. For instance, previous works have shown that gene regulatory interactions can be estimated from the complete matrix of gene expression measurement. Yet, till date, few algorithms have been proposed for the inference of gene regulatory network from gene expression data with missing values. We describe a nonlinear dynamic stochastic model for the evolution of gene expression. The model captures the structural, dynamical, and the nonlinear natures of the underlying biomolecular systems. We present point-based Gaussian approximation (PBGA) filters for joint state and parameter estimation of the system with one-step or two-step missing measurements . The PBGA filters use Gaussian approximation and various quadrature rules, such as the unscented transform (UT), the third-degree cubature rule and the central difference rule for computing the related posteriors. The proposed algorithm is evaluated with satisfying results for synthetic networks, in silico networks released as a part of the DREAM project, and the real biological network, the in vivo reverse engineering and modeling assessment (IRMA) network of yeast Saccharomyces cerevisiae . PBGA filters are proposed to elucidate the underlying gene regulatory network (GRN) from time series gene expression data that contain missing values. In our state-space model, we proposed a measurement model that incorporates the effect of the missing data points into the sequential algorithm. This approach produces a better inference of the model parameters and hence, more accurate prediction of the underlying GRN compared to when using the conventional Gaussian approximation (GA) filters ignoring the missing data points.
The University of Colorado OSO-8 spectrometer experiment. IV - Mission operations
NASA Technical Reports Server (NTRS)
Hansen, E. R.; Bruner, E. C., Jr.
1979-01-01
The remote operation of two high-resolution ultraviolet spectrometers on the OSO-8 satellite is discussed. Mission operations enabled scientific observers to plan observations based on current solar data, interact with the observing program using real- or near real-time data and commands, evaluate quick-look instrument data, and analyze the observations for publication. During routine operations, experiments were planned a day prior to their execution, and the data from these experiments received a day later. When a shorter turnaround was required, a real-time mode was available. Here, the real-time data and command links into the remote control center were used to evaluate experiment operation and make satellite pointing or instrument configuration changes with a 1-90 minute turnaround.
Vaikousi, Hariklia; Biliaderis, Costas G; Koutsoumanis, Konstantinos P
2009-08-15
The applicability of a microbial Time Temperature Indicator (TTI) prototype, based on the growth and metabolic activity of a Lactobacillus sakei strain developed in a previous study, in monitoring quality of modified atmosphere packed (MAP) minced beef was evaluated at conditions simulating the chill chain. At all storage temperatures examined (0, 5, 10, 15 degrees C), the results showed that lactic acid bacteria (LAB) were the dominant bacteria and can be used as a good spoilage index of MAP minced beef. The end of product's shelf life as revealed by the sensory evaluation coincided with a LAB population level of 7 log(10) CFU/g. For all temperatures tested, the growth of L. sakei in the TTI resembled closely the growth of LAB in the meat product, with similar temperature dependence of the micro(max) and thus similar activation energy values calculated as 111.90 and 106.90 kJ/mol, for the two systems, respectively. In addition, the end point of TTI colour change coincided with the time of sensory rejection point of the beef product during its storage under isothermal chilled temperature conditions. The estimated activation energy, E(alpha), values obtained for parameters related to the response of DeltaE (total colour change of the TTI) describing the kinetics of colour change of the TTI during isothermal storage (i.e. the maximum specific rate of DeltaEpsilon evolution curve, micro(DeltaEpsilon), and also the reciprocal of t(i), time at which half of the maximum DeltaEpsilon is reached), were 112.77 and 127.28 kJ/mol, respectively. Finally, the application of the microbial TTI in monitoring the quality deterioration of MAP minced beef due to spoilage was further evaluated under dynamic conditions of storage, using two separate low temperature periodic changing scenarios, resembling the actual conditions occurring in the distribution chill chain. The results showed that the end point of TTI, after storage at those fluctuating temperature conditions, was noted very close to the end of product's sensorial shelf life. This finding points to the applicability of the developed microbial TTI as a valuable tool for monitoring the quality status during distribution and storage of chilled meat products, which are spoiled by lactic acid bacteria or other bacteria exhibiting similar kinetic responses and spoilage potential.
Sveinsdóttir, Kristbjörg; Länsberg, John-Kalle; Sveinsdóttir, Snjólaug; Garwicz, Martin; Ohlsson, Lennart; Hellström, Ann; Smith, Lois; Gram, Magnus; Ley, David
2018-01-01
Cerebellar growth is impeded following very preterm birth in human infants and the observed reduction in cerebellar volume is associated with neurodevelopmental impairment. Decreased levels of circulating insulin-like growth factor 1 (IGF-1) are associated with decreased cerebellar volume. The relationship between preterm birth, circulating IGF-1, and key cell populations supporting cerebellar proliferation is unknown. The aim of this study was to evaluate the effect of preterm birth on postnatal growth, circulating IGF-1, and cerebellar maturation in a preterm rabbit pup model. Preterm rabbit pups (PT) were delivered by cesarean section at day 29 of gestation, cared for in closed incubators with humidified air, and gavage fed with formula. Control term pups (T) delivered by spontaneous vaginal delivery at day 32 of gestation were housed and fed by their lactating doe. In vivo perfusion-fixation for immunohistochemical evaluation of cerebellar proliferation, cell maturation, and apoptosis was performed at repeated time points in PT and T pups. Results show that the mean weight of the pups and circulating IGF-1 protein levels were lower in the PT group at all time points (p < 0.05) than in the T group. Postnatal weight development correlated with circulating IGF-1 (r2 = 0.89) independently of gestational age at birth and postnatal age. The proliferative (Ki-67-positive) portion of the external granular layer (EGL) was decreased in the PT group at postnatal day 2 (P2) compared to in the T group (p = 0.01). Purkinje cells exhibited decreased calbindin staining at P0 (p = 0.003), P2 (p = 0.004), and P5 (p = 0.04) in the PT group compared to in the T group. Staining for sonic hedgehog was positive in neuronal EGL progenitors and Purkinje cells at early time points but was restricted to a well-defined Purkinje cell monolayer at later time points. Preterm birth in rabbit pups is associated with lower circulating levels of IGF-1, decreased postnatal growth, and decreased cerebellar EGL proliferation and Purkinje cell maturation. The preterm rabbit pup model exhibits important characteristics of human preterm birth, and may thus be suitable for the evaluation of interventions aiming to modify growth and cerebellar development in the preterm population. PMID:28972955
NASA Astrophysics Data System (ADS)
Klapa, Przemyslaw; Mitka, Bartosz; Zygmunt, Mariusz
2017-12-01
The terrestrial laser scanning technology has a wide spectrum of applications, from land surveying, civil engineering and architecture to archaeology. The technology is capable of obtaining, in a short time, accurate coordinates of points which represent the surface of objects. Scanning of buildings is therefore a process which ensures obtaining information on all structural elements a building. The result is a point cloud consisting of millions of elements which are a perfect source of information on the object and its surrounding. The photogrammetric techniques allow documenting an object in high resolution in the form of orthophoto plans, or are a basis to develop 2D documentation or obtain point clouds for objects and 3D modelling. Integration of photogrammetric data and TLS brings a new quality in surveying historic monuments. Historic monuments play an important cultural and historical role. Centuries-old buildings require constant renovation and preservation of their structural and visual invariability while maintaining safety of people who use them. The full process of surveying allows evaluating the actual condition of monuments and planning repairs and renovations. Huge sizes and specific types of historic monuments cause problems in obtaining reliable and full information on them. The TLS technology allows obtaining such information in a short time and is non-invasive. A point cloud is not only a basis for developing architectural and construction documentation or evaluation of actual condition of a building. It also is a real visualization of monuments and their entire environment. The saved image of object surface can be presented at any time and place. A cyclical TLS survey of historic monuments allows detecting structural changes and evaluating damage and changes that cause deformation of monument’s components. The paper presents application of integrated photogrammetric data and TLS illustrated on an example of historic monuments from southern Poland. The cartographic materials are a basis for determining the actual condition of monuments and performing repair works. The materials also supplement the archive of monuments by means of recording the actual image of a monument in a virtual space.
The relevance of time series in molecular ecology and conservation biology.
Habel, Jan C; Husemann, Martin; Finger, Aline; Danley, Patrick D; Zachos, Frank E
2014-05-01
The genetic structure of a species is shaped by the interaction of contemporary and historical factors. Analyses of individuals from the same population sampled at different points in time can help to disentangle the effects of current and historical forces and facilitate the understanding of the forces driving the differentiation of populations. The use of such time series allows for the exploration of changes at the population and intraspecific levels over time. Material from museum collections plays a key role in understanding and evaluating observed population structures, especially if large numbers of individuals have been sampled from the same locations at multiple time points. In these cases, changes in population structure can be assessed empirically. The development of new molecular markers relying on short DNA fragments (such as microsatellites or single nucleotide polymorphisms) allows for the analysis of long-preserved and partially degraded samples. Recently developed techniques to construct genome libraries with a reduced complexity and next generation sequencing and their associated analysis pipelines have the potential to facilitate marker development and genotyping in non-model species. In this review, we discuss the problems with sampling and available marker systems for historical specimens and demonstrate that temporal comparative studies are crucial for the estimation of important population genetic parameters and to measure empirically the effects of recent habitat alteration. While many of these analyses can be performed with samples taken at a single point in time, the measurements are more robust if multiple points in time are studied. Furthermore, examining the effects of habitat alteration, population declines, and population bottlenecks is only possible if samples before and after the respective events are included. © 2013 The Authors. Biological Reviews © 2013 Cambridge Philosophical Society.
Physical activity, sedentary behavior, and academic performance in Finnish children.
Syväoja, Heidi J; Kantomaa, Marko T; Ahonen, Timo; Hakonen, Harto; Kankaanpää, Anna; Tammelin, Tuija H
2013-11-01
This study aimed to determine the relationships between objectively measured and self-reported physical activity, sedentary behavior, and academic performance in Finnish children. Two hundred and seventy-seven children from five schools in the Jyväskylä school district in Finland (58% of the 475 eligible students, mean age = 12.2 yr, 56% girls) participated in the study in the spring of 2011. Self-reported physical activity and screen time were evaluated with questions used in the WHO Health Behavior in School-Aged Children study. Children's physical activity and sedentary time were measured objectively by using an ActiGraph GT1M/GT3X accelerometer for seven consecutive days. A cutoff value of 2296 counts per minute was used for moderate-to-vigorous physical activity (MVPA) and 100 counts per minute for sedentary time. Grade point averages were provided by the education services of the city of Jyväskylä. ANOVA and linear regression analysis were used to analyze the relationships among physical activity, sedentary behavior, and academic performance. Objectively measured MVPA (P = 0.955) and sedentary time (P = 0.285) were not associated with grade point average. However, self-reported MVPA had an inverse U-shaped curvilinear association with grade point average (P = 0.001), and screen time had a linear negative association with grade point average (P = 0.002), after adjusting for sex, children's learning difficulties, highest level of parental education, and amount of sleep. In this study, self-reported physical activity was directly, and screen time inversely, associated with academic achievement. Objectively measured physical activity and sedentary time were not associated with academic achievement. Objective and subjective measures may reflect different constructs and contexts of physical activity and sedentary behavior in association with academic outcomes.
Joshi, Shuchi N; Srinivas, Nuggehally R; Parmar, Deven V
2018-03-01
Our aim was to develop and validate the extrapolative performance of a regression model using a limited sampling strategy for accurate estimation of the area under the plasma concentration versus time curve for saroglitazar. Healthy subject pharmacokinetic data from a well-powered food-effect study (fasted vs fed treatments; n = 50) was used in this work. The first 25 subjects' serial plasma concentration data up to 72 hours and corresponding AUC 0-t (ie, 72 hours) from the fasting group comprised a training dataset to develop the limited sampling model. The internal datasets for prediction included the remaining 25 subjects from the fasting group and all 50 subjects from the fed condition of the same study. The external datasets included pharmacokinetic data for saroglitazar from previous single-dose clinical studies. Limited sampling models were composed of 1-, 2-, and 3-concentration-time points' correlation with AUC 0-t of saroglitazar. Only models with regression coefficients (R 2 ) >0.90 were screened for further evaluation. The best R 2 model was validated for its utility based on mean prediction error, mean absolute prediction error, and root mean square error. Both correlations between predicted and observed AUC 0-t of saroglitazar and verification of precision and bias using Bland-Altman plot were carried out. None of the evaluated 1- and 2-concentration-time points models achieved R 2 > 0.90. Among the various 3-concentration-time points models, only 4 equations passed the predefined criterion of R 2 > 0.90. Limited sampling models with time points 0.5, 2, and 8 hours (R 2 = 0.9323) and 0.75, 2, and 8 hours (R 2 = 0.9375) were validated. Mean prediction error, mean absolute prediction error, and root mean square error were <30% (predefined criterion) and correlation (r) was at least 0.7950 for the consolidated internal and external datasets of 102 healthy subjects for the AUC 0-t prediction of saroglitazar. The same models, when applied to the AUC 0-t prediction of saroglitazar sulfoxide, showed mean prediction error, mean absolute prediction error, and root mean square error <30% and correlation (r) was at least 0.9339 in the same pool of healthy subjects. A 3-concentration-time points limited sampling model predicts the exposure of saroglitazar (ie, AUC 0-t ) within predefined acceptable bias and imprecision limit. Same model was also used to predict AUC 0-∞ . The same limited sampling model was found to predict the exposure of saroglitazar sulfoxide within predefined criteria. This model can find utility during late-phase clinical development of saroglitazar in the patient population. Copyright © 2018 Elsevier HS Journals, Inc. All rights reserved.
Sensors for 3D Imaging: Metric Evaluation and Calibration of a CCD/CMOS Time-of-Flight Camera.
Chiabrando, Filiberto; Chiabrando, Roberto; Piatti, Dario; Rinaudo, Fulvio
2009-01-01
3D imaging with Time-of-Flight (ToF) cameras is a promising recent technique which allows 3D point clouds to be acquired at video frame rates. However, the distance measurements of these devices are often affected by some systematic errors which decrease the quality of the acquired data. In order to evaluate these errors, some experimental tests on a CCD/CMOS ToF camera sensor, the SwissRanger (SR)-4000 camera, were performed and reported in this paper. In particular, two main aspects are treated: the calibration of the distance measurements of the SR-4000 camera, which deals with evaluation of the camera warm up time period, the distance measurement error evaluation and a study of the influence on distance measurements of the camera orientation with respect to the observed object; the second aspect concerns the photogrammetric calibration of the amplitude images delivered by the camera using a purpose-built multi-resolution field made of high contrast targets.
The utility of the KJOC score in professional baseball in the United States.
Franz, Justin O; McCulloch, Patrick C; Kneip, Chris J; Noble, Philip C; Lintner, David M
2013-09-01
The Kerlan-Jobe Orthopaedic Clinic (KJOC) Shoulder and Elbow questionnaire has been shown by previous studies to be more sensitive than other validated subjective measurement tools in the detection of upper extremity dysfunction in overhead-throwing athletes. The primary objective was to establish normative data for KJOC scores in professional baseball players in the United States. The secondary objectives were to evaluate the effect of player age, playing position, professional competition level, history of injury, history of surgery, and time point of administration on the KJOC score. Cross-sectional study; Level of evidence, 3. From 2011 to 2012, a total of 203 major league and minor league baseball players within the Houston Astros professional baseball organization completed the KJOC questionnaire. The questionnaire was administered at 3 time points: spring training 2011, end of season 2011, and spring training 2012. The KJOC scores were analyzed for significant differences based on player age, injury history, surgery history, fielding position, competition level, self-reported playing status, and time point of KJOC administration. The average KJOC score among healthy players with no history of injury was 97.1 for major league players and 96.8 for minor league players. The time point of administration did not significantly affect the final KJOC score (P = .224), and KJOC outcomes did not vary with player age (r = -0.012; P = .867). Significantly lower average KJOC scores were reported by players with a history of upper extremity injury (86.7; P < .001) and upper extremity surgery (75.4; P < .0001). The KJOC results did vary with playing position (P = .0313), with the lowest average scores being reported by pitchers (90.9) and infielders (91.3). This study establishes a quantitative baseline for the future evaluation of professional baseball players with the KJOC score. Age and time of administration had no significant effect on the outcome of the KJOC score. Missed practices or games within the previous year because of injury were the most significant demographic predictors of lower KJOC scores. The KJOC score was shown to be a sensitive measurement tool for detecting subtle changes in the upper extremity performance of the professional baseball population studied.
The trajectory of scientific discovery: concept co-occurrence and converging semantic distance.
Cohen, Trevor; Schvaneveldt, Roger W
2010-01-01
The paradigm of literature-based knowledge discovery originated by Swanson involves finding meaningful associations between terms or concepts that have not occurred together in any previously published document. While several automated approaches have been applied to this problem, these generally evaluate the literature at a point in time, and do not evaluate the role of change over time in distributional statistics as an indicator of meaningful implicit associations. To address this issue, we develop and evaluate Symmetric Random Indexing (SRI), a novel variant of the Random Indexing (RI) approach that is able to measure implicit association over time. SRI is found to compare favorably to existing RI variants in the prediction of future direct co-occurrence. Summary statistics over several experiments suggest a trend of converging semantic distance prior to the co-occurrence of key terms for two seminal historical literature-based discoveries.
Enhanced Precision Time Synchronization for Wireless Sensor Networks
Cho, Hyuntae; Kim, Jongdeok; Baek, Yunju
2011-01-01
Time synchronization in wireless sensor networks (WSNs) is a fundamental issue for the coordination of distributed entities and events. Nondeterministic latency, which may decrease the accuracy and precision of time synchronization can occur at any point in the network layers. Specially, random back-off by channel contention leads to a large uncertainty. In order to reduce the large nondeterministic uncertainty from channel contention, we propose an enhanced precision time synchronization protocol in this paper. The proposed method reduces the traffic needed for the synchronization procedure by selectively forwarding the packet. Furthermore, the time difference between sensor nodes increases as time advances because of the use of a clock source with a cheap crystal oscillator. In addition, we provide a means to maintain accurate time by adopting hardware-assisted time stamp and drift correction. Experiments are conducted to evaluate the performance of the proposed method, for which sensor nodes are designed and implemented. According to the evaluation results, the performance of the proposed method is better than that of a traditional time synchronization protocol. PMID:22164035
Enhanced precision time synchronization for wireless sensor networks.
Cho, Hyuntae; Kim, Jongdeok; Baek, Yunju
2011-01-01
Time synchronization in wireless sensor networks (WSNs) is a fundamental issue for the coordination of distributed entities and events. Nondeterministic latency, which may decrease the accuracy and precision of time synchronization can occur at any point in the network layers. Specially, random back-off by channel contention leads to a large uncertainty. In order to reduce the large nondeterministic uncertainty from channel contention, we propose an enhanced precision time synchronization protocol in this paper. The proposed method reduces the traffic needed for the synchronization procedure by selectively forwarding the packet. Furthermore, the time difference between sensor nodes increases as time advances because of the use of a clock source with a cheap crystal oscillator. In addition, we provide a means to maintain accurate time by adopting hardware-assisted time stamp and drift correction. Experiments are conducted to evaluate the performance of the proposed method, for which sensor nodes are designed and implemented. According to the evaluation results, the performance of the proposed method is better than that of a traditional time synchronization protocol.
Advanced crew procedures development techniques
NASA Technical Reports Server (NTRS)
Arbet, J. D.; Benbow, R. L.; Mangiaracina, A. A.; Mcgavern, J. L.; Spangler, M. C.; Tatum, I. C.
1975-01-01
The development of an operational computer program, the Procedures and Performance Program (PPP), is reported which provides a procedures recording and crew/vehicle performance monitoring capability. The PPP provides real time CRT displays and postrun hardcopy of procedures, difference procedures, performance, performance evaluation, and training script/training status data. During post-run, the program is designed to support evaluation through the reconstruction of displays to any point in time. A permanent record of the simulation exercise can be obtained via hardcopy output of the display data, and via magnetic tape transfer to the Generalized Documentation Processor (GDP). Reference procedures data may be transferred from the GDP to the PPP.
Schönig, W
2002-01-01
Public and private expenditure in health recovery programmes for mothers and their children is stagnating. A focal point to turn around this trend is to convince the responsible statury bodies by proving both effectiveness and efficiency of these programmes. The paper suggests the application of the break-even analysis on a time-based principle. A primary calculation with the data of a major German evaluation shows significant savings if the success of the health recovery programmes holds for at least 1.19 years. Available data does not cover such a long period.
Hoemann, Caroline; Kandel, Rita; Roberts, Sally; Saris, Daniel B.F.; Creemers, Laura; Mainil-Varlet, Pierre; Méthot, Stephane; Hollander, Anthony P.; Buschmann, Michael D.
2011-01-01
Cartilage repair strategies aim to resurface a lesion with osteochondral tissue resembling native cartilage, but a variety of repair tissues are usually observed. Histology is an important structural outcome that could serve as an interim measure of efficacy in randomized controlled clinical studies. The purpose of this article is to propose guidelines for standardized histoprocessing and unbiased evaluation of animal tissues and human biopsies. Methods were compiled from a literature review, and illustrative data were added. In animal models, treatments are usually administered to acute defects created in healthy tissues, and the entire joint can be analyzed at multiple postoperative time points. In human clinical therapy, treatments are applied to developed lesions, and biopsies are obtained, usually from a subset of patients, at a specific time point. In striving to standardize evaluation of structural endpoints in cartilage repair studies, 5 variables should be controlled: 1) location of biopsy/sample section, 2) timing of biopsy/sample recovery, 3) histoprocessing, 4) staining, and 5) blinded evaluation with a proper control group. Histological scores, quantitative histomorphometry of repair tissue thickness, percentage of tissue staining for collagens and glycosaminoglycan, polarized light microscopy for collagen fibril organization, and subchondral bone integration/structure are all relevant outcome measures that can be collected and used to assess the efficacy of novel therapeutics. Standardized histology methods could improve statistical analyses, help interpret and validate noninvasive imaging outcomes, and permit cross-comparison between studies. Currently, there are no suitable substitutes for histology in evaluating repair tissue quality and cartilaginous character. PMID:26069577
Predictors of Functional Change in a Skilled Nursing Facility Population.
Gustavson, Allison M; Falvey, Jason R; Forster, Jeri E; Stevens-Lapsley, Jennifer E
2017-06-21
Inability to obtain sufficient gains in function during a skilled nursing facility (SNF) stay impacts patients' functional trajectories and susceptibility to adverse events. The purpose of this study was to identify predictors of functional change in patients temporarily residing in an SNF following hospitalization. One hundred forty patients admitted to a single SNF from the hospital who had both evaluation and discharge measures of physical function documented were included. Data from the Minimum Data Set 3.0 and electronic medical record were extracted to record clinical and demographic characteristics. The Short Physical Performance Battery (SPPB) was administered by rehabilitation therapists at evaluation and discharge. The SPPB consists of balance tests, gait speed, and a timed 5-time sit-to-stand test. The Patient Health Questionnaire (PHQ-9) Screening Tool for Depression was the only significant predictor of change in gait speed over an SNF stay. Eighty-seven percent of patients achieved a clinically meaningful change in the SPPB of 1 point or greater from evaluation to discharge, with 78% demonstrating a clinically meaningful change of 0.1 m/s or greater on gait speed. However, 69% of patients demonstrated SPPB scores of 6 points or less and 57% ambulated less than 0.65 m/s at the time of discharge from the SNF, which indicates severe disability. Poor physical function following an SNF stay places older adult at significant risk for adverse events including rehospitalization, future disability, and institutionalization. Understanding the predictors of functional change from evaluation to discharge may direct efforts toward developing innovative and effective interventions to improve function trajectories for older adults following an acute hospitalization.
2013-01-01
Background The stigma of mental illness among medical students is a prevalent concern that has far reaching negative consequences. Attempts to combat this stigma through educational initiatives have had mixed results. This study examined the impact of a one-time contact-based educational intervention on the stigma of mental illness among medical students and compared this with a multimodal undergraduate psychiatry course at the University of Calgary, Canada that integrates contact-based educational strategies. Attitudes towards mental illness were compared with those towards type 2 diabetes mellitus (T2DM). Method A cluster-randomized trial design was used to evaluate the impact of contact-based educational interventions delivered at two points in time. The impact was assessed by collecting data at 4 time points using the Opening Minds Scale for Health Care Providers (OMS-HC) to assess changes in stigma. Results Baseline surveys were completed by 62% (n=111) of students before the start of the course and post-intervention ratings were available from 90 of these. Stigma scores for both groups were significantly reduced upon course completion (p < 0.0001), but were not significantly changed following the one-time contact based educational intervention in the primary analysis. Student confidence in working with people with a mental illness and interest in a psychiatric career was increased at the end of the course. Stigma towards mental illness remained greater than for T2DM at all time points. Conclusions Psychiatric education can decrease the stigma of mental illness and increase student confidence. However, one-time, contact-based educational interventions require further evaluation in this context. The key components are postulated to be contact, knowledge and attention to process, where attending to the student’s internal experience of working with people with mental illness is an integral factor in modulating perceptions of mental illness and a psychiatric career. PMID:24156397
Papish, Andriyka; Kassam, Aliya; Modgill, Geeta; Vaz, Gina; Zanussi, Lauren; Patten, Scott
2013-10-24
The stigma of mental illness among medical students is a prevalent concern that has far reaching negative consequences. Attempts to combat this stigma through educational initiatives have had mixed results. This study examined the impact of a one-time contact-based educational intervention on the stigma of mental illness among medical students and compared this with a multimodal undergraduate psychiatry course at the University of Calgary, Canada that integrates contact-based educational strategies. Attitudes towards mental illness were compared with those towards type 2 diabetes mellitus (T2DM). A cluster-randomized trial design was used to evaluate the impact of contact-based educational interventions delivered at two points in time. The impact was assessed by collecting data at 4 time points using the Opening Minds Scale for Health Care Providers (OMS-HC) to assess changes in stigma. Baseline surveys were completed by 62% (n=111) of students before the start of the course and post-intervention ratings were available from 90 of these. Stigma scores for both groups were significantly reduced upon course completion (p < 0.0001), but were not significantly changed following the one-time contact based educational intervention in the primary analysis. Student confidence in working with people with a mental illness and interest in a psychiatric career was increased at the end of the course. Stigma towards mental illness remained greater than for T2DM at all time points. Psychiatric education can decrease the stigma of mental illness and increase student confidence. However, one-time, contact-based educational interventions require further evaluation in this context. The key components are postulated to be contact, knowledge and attention to process, where attending to the student's internal experience of working with people with mental illness is an integral factor in modulating perceptions of mental illness and a psychiatric career.
Numerical Study of a High Head Francis Turbine with Measurements from the Francis-99 Project
NASA Astrophysics Data System (ADS)
Wallimann, H.; Neubauer, R.
2015-01-01
For the Francis-99 project initiated by the Norwegian University of Science and Technology (NTNU, Norway) and the Luleå University of Technology (LTU, Sweden) numerical flow simulation has been performed and the results compared to experimentally obtained data. The full machine including spiral casing, stay vanes, guide vanes, runner and draft tube was simulated transient for three operating points defined by the Francis-99 organisers. Two sets of results were created with differing time steps. Additionally, a reduced domain was simulated in a stationary manner to create a complete cut along constant prototype head and constant prototype discharge. The efficiency values and shape of the curves have been investigated and compared to the experimental data. Special attention has been given to rotor stator interaction (RSI). Signals from several probes and their counterpart in the simulation have been processed to evaluate the pressure fluctuations occurring due to the RSI. The direct comparison of the hydraulic efficiency obtained by the full machine simulation compared to the experimental data showed no improvement when using a 1° time step compared to a coarser 2° time step. At the BEP the 2° time step even showed a slightly better result with an absolute deviation 1.08% compared with 1.24% for the 1° time step. At the other two operating points the simulation results were practically identical but fell short of predicting the measured values. The RSI evaluation was done using the results of the 2° time step simulation, which proved to be an adequate setting to reproduce pressure signals with peaks at the correct frequencies. The simulation results showed the highest amplitudes in the vaneless space at the BEP operating point at a location different from the probe measurements available. This implies that not only the radial distance, but the shape of the vaneless space influences the RSI.
Freiberg, Matthew S; Bebu, Ionut; Tracy, Russell; So-Armah, Kaku; Okulicz, Jason; Ganesan, Anuradha; Armstrong, Adam; O'Bryan, Thomas; Rimland, David; Justice, Amy C; Agan, Brian K
2016-01-01
The mechanism underlying the excess risk of non-AIDS diseases among HIV infected people is unclear. HIV associated inflammation/hypercoagulability likely plays a role. While antiretroviral therapy (ART) may return this process to pre-HIV levels, this has not been directly demonstrated. We analyzed data/specimens on 249 HIV+ participants from the US Military HIV Natural History Study, a prospective, multicenter observational cohort of >5600 active duty military personnel and beneficiaries living with HIV. We used stored blood specimens to measure D-dimer and Interleukin-6 (IL-6) at three time points: pre-HIV seroconversion, ≥6 months post-HIV seroconversion but prior to ART initiation, and ≥6 months post-ART with documented HIV viral suppression on two successive evaluations. We evaluated the changes in biomarker levels between time points, and the association between these biomarker changes and future non-AIDS events. During a median follow-up of 3.7 years, there were 28 incident non-AIDS diseases. At ART initiation, the median CD4 count was 361cells/mm3; median duration of documented HIV infection 392 days; median time on ART was 354 days. Adjusted mean percent increase in D-dimer levels from pre-seroconversion to post-ART was 75.1% (95% confidence interval 24.6-148.0, p = 0.002). This increase in D-dimer was associated with a significant 22% increase risk of future non-AIDS events (p = 0.03). Changes in IL-6 levels across time points were small and not associated with future non-AIDS events. In conclusion, ART initiation and HIV viral suppression does not eliminate HIV associated elevation in D-dimer levels. This residual pathology is associated with an increased risk of future non-AIDS diseases.
Hadžibajramović, Emina; Ahlborg, Gunnar; Håkansson, Carita; Lundgren-Nilsson, Åsa; Grimby-Ekman, Anna
2015-12-01
Psychosocial stress at work is one of the most important factors behind increasing sick-leave rates. In addition to work stressors, it is important to account for non-work-related stressors when assessing stress responses. In this study, a modified version of the Stress-Energy Questionnaire (SEQ), the SEQ during leisure time (SEQ-LT) was introduced for assessing the affective stress response during leisure time. The aim of this study was to investigate the internal construct validity of the SEQ-LT. A second aim was to define the cut-off points for the scales, which could indicate high and low levels of leisure-time stress and energy, respectively. Internal construct validity of the SEQ-LT was evaluated using a Rasch analysis. We examined the unidimensionality and other psychometric properties of the scale by the fit to the Rasch model. A criterion-based approach was used for classification into high and low stress/energy levels. The psychometric properties of the stress and energy scales of the SEQ-LT were satisfactory, having accommodated for local dependency. The cut-off point for low stress was proposed to be in the interval between 2.45 and 3.02 on the Rasch metric score; while for high stress, it was between 3.65 and 3.90. The suggested cut-off points for the low and high energy levels were values between 1.73-1.97 and 2.66-3.08, respectively. The stress and energy scale of the SEQ-LT satisfied the measurement criteria defined by the Rasch analysis and it provided a useful tool for non-work-related assessment of stress responses. We provide guidelines on how to interpret the scale values. © 2015 the Nordic Societies of Public Health.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roper, J; Bradshaw, B; Godette, K
Purpose: To create a knowledge-based algorithm for prostate LDR brachytherapy treatment planning that standardizes plan quality using seed arrangements tailored to individual physician preferences while being fast enough for real-time planning. Methods: A dataset of 130 prior cases was compiled for a physician with an active prostate seed implant practice. Ten cases were randomly selected to test the algorithm. Contours from the 120 library cases were registered to a common reference frame. Contour variations were characterized on a point by point basis using principle component analysis (PCA). A test case was converted to PCA vectors using the same process andmore » then compared with each library case using a Mahalanobis distance to evaluate similarity. Rank order PCA scores were used to select the best-matched library case. The seed arrangement was extracted from the best-matched case and used as a starting point for planning the test case. Computational time was recorded. Any subsequent modifications were recorded that required input from a treatment planner to achieve an acceptable plan. Results: The computational time required to register contours from a test case and evaluate PCA similarity across the library was approximately 10s. Five of the ten test cases did not require any seed additions, deletions, or moves to obtain an acceptable plan. The remaining five test cases required on average 4.2 seed modifications. The time to complete manual plan modifications was less than 30s in all cases. Conclusion: A knowledge-based treatment planning algorithm was developed for prostate LDR brachytherapy based on principle component analysis. Initial results suggest that this approach can be used to quickly create treatment plans that require few if any modifications by the treatment planner. In general, test case plans have seed arrangements which are very similar to prior cases, and thus are inherently tailored to physician preferences.« less
NASA Astrophysics Data System (ADS)
Harima, Ken; Choy, Suelynn; Rizos, Chris; Kogure, Satoshi
2017-09-01
This paper presents an investigation into the performance of real-time Global Navigation Satellite Systems (GNSS) Precise Point Positioning (PPP) in New Zealand. The motivation of the research is to evaluate the feasibility of using PPP technique and a satellite based augmentation system such as the Japanese Quasi-Zenith Satellite System (QZSS) to deliver a real-time precise positioning solution in support of a nation-wide high accuracy GNSS positioning coverage in New Zealand. Two IGS real-time correction streams are evaluated alongside with the PPP correction messages transmitted by the QZSS satellite known as MDC1. MDC1 corrections stream is generated by Japan Aerospace Exploration Agency (JAXA) using the Multi-GNSS Advanced Demonstration tool for Orbit and Clock Analysis (MADOCA) software and are currently transmitted in test mode by the QZSS satellite. The IGS real-time streams are the CLK9B real-time corrections stream generated by the French Centre National D'études Spatiales (CNES) using the PPP-Wizard software, and the CLK81 real-time corrections stream produced by GMV using their MagicGNSS software. GNSS data is collected from six New Zealand CORS stations operated by Land Information New Zealand (LINZ) over a one-week period in 2015. GPS and GLONASS measurements are processed in a real-time PPP mode using the satellite orbit and clock corrections from the real-time streams. The results show that positioning accuracies of 6 cm in horizontal component and 15 cm in vertical component can be achieved in real-time PPP. The real-time GPS+GLONASS PPP solution required 30 minutes to converge to within 10 cm horizontal positioning accuracy.
Implementation of a web-based medication tracking system in a large academic medical center.
Calabrese, Sam V; Williams, Jonathan P
2012-10-01
Pharmacy workflow efficiencies achieved through the use of an electronic medication-tracking system are described. Medication dispensing turnaround times at the inpatient pharmacy of a large hospital were evaluated before and after transition from manual medication tracking to a Web-based tracking process involving sequential bar-code scanning and real-time monitoring of medication status. The transition was carried out in three phases: (1) a workflow analysis, including the identification of optimal points for medication scanning with hand-held wireless devices, (2) the phased implementation of an automated solution and associated hardware at a central dispensing pharmacy and three satellite locations, and (3) postimplementation data collection to evaluate the impact of the new tracking system and areas for improvement. Relative to the manual tracking method, electronic medication tracking allowed the capture of far more data points, enabling the pharmacy team to delineate the time required for each step of the medication dispensing process and to identify the steps most likely to involve delays. A comparison of baseline and postimplementation data showed substantial reductions in overall medication turnaround times with the use of the Web-based tracking system (time reductions of 45% and 22% at the central and satellite sites, respectively). In addition to more accurate projections and documentation of turnaround times, the Web-based tracking system has facilitated quality-improvement initiatives. Implementation of an electronic tracking system for monitoring the delivery of medications provided a comprehensive mechanism for calculating turnaround times and allowed the pharmacy to identify bottlenecks within the medication distribution system. Altering processes removed these bottlenecks and decreased delivery turnaround times.
Lavisse, Sonia; Lejeune, Pascale; Rouffiac, Valérie; Elie, Nicolas; Bribes, Estelle; Demers, Brigitte; Vrignaud, Patricia; Bissery, Marie-Christine; Brulé, Aude; Koscielny, Serge; Péronneau, Pierre; Lassau, Nathalie
2008-02-01
To evaluate the early tumor vasculature disrupting effects of the AVE8062 molecule and the feasibility of dynamic contrast-enhanced ultrasonography (DCE-US) in the quantitative assessment of these effects. AVE8062 was administered at a single dose (41 mg/kg) to 40 melanoma-bearing nude mice, which were all imaged before and after drug administration (5 + 15 minutes, 1, 6, and 24 hours). Using an ultrasound scanner (Aplio, Toshiba), intratumor vessels were counted in power Doppler mode and tumor microvasculature was assessed in a specific harmonic mode associated with a perfusion and quantification software for contrast-uptake quantification (Sonovue, Bracco). The peak intensity (PI), time-to-PI (T PI), and full-width at half maximum (FWHM) were extracted from the time-intensity curves expressed as linear raw data. Histologic analysis evaluated microvessel density (MVD) and necrosis at each time point studied. Statistical significance was estimated (paired sum rank and Mann-Whitney tests) to evaluate drug activity and to compare its efficacy at the different time points. In power Doppler mode, intratumoral vessels depletion started 15 minutes postinjection (32%, P = 0.004) and the decrease was maximal at 6 hours (51%, P = 0.002). PI decreased by 3.5- and 45.7-fold at 1 and 6 hours, respectively, compared with preinjection values (P = 0.016 and P = 0.008). The decrease at 6 hours was significantly different from the variation at 1 hour (P = 0.0012) and at 24 hours (P = 0.0008). T PI and FWHM showed a significant increase exclusively at 6 hours (P = 0.0034, P = 0.0039). Histology revealed significantly decreased MVD and increased necrosis at 24 hours (P < 0.01). DCE-US allowed quantitative in vivo evaluation of the functional effects of AVE8062, which was found most effective on tumoral microvasculature 6 hours after its administration. A clinical phase-1 study of AVE8062 is ongoing using the same ultrasonography methodology before and 6 and 24 hours postadministration.
ERIC Educational Resources Information Center
Gu, Lin; Lockwood, John; Powers, Donald E.
2015-01-01
Standardized tests are often designed to provide only a snapshot of test takers' knowledge, skills, or abilities at a single point in time. Sometimes, however, they are expected to serve more demanding functions, one of them is assessing change in knowledge, skills, or ability over time because of learning effects.The latter is the case for the…
Hernández-García, Raúl; Garza-González, Elvira; Miller, Mark; Arteaga-Muller, Giovanna; Galván-de los Santos, Alejandra María; Camacho-Ortiz, Adrián
2015-01-01
For clinicians, a practical bedside tool for severity assessment and prognosis of patients with Clostridium difficile infection is a highly desirable unmet medical need. Two general teaching hospitals in northeast Mexico. Adult patients with C. difficile infection. Prospective observational study. Patients included had a median of 48 years of age, 54% of male gender and an average of 24.3 days length of hospital stay. Third generation cephalosporins were the antibiotics most commonly used prior to C. difficile infection diagnosis. Patients diagnosed with C. difficile infection had a median ATLAS score of 4 and 56.7% of the subjects had a score between 4 and 7 points. Patients with a score of 8 through 10 points had 100% mortality. The ATLAS score is a potentially useful tool for the routine evaluation of patients at the time of C. difficile infection diagnosis. At 30 days post-diagnosis, patients with a score of ≤3 points had 100% survival while all of those with scores ≥8 died. Patients with scores between 4 and 7 points had a greater probability of colectomy with an overall cure rate of 70.1%. Copyright © 2015 Elsevier Editora Ltda. All rights reserved.
Impact of Embedded Military Metal Alloys on Skeletal Physiology in an Animal Model
2017-04-04
turnover were completed and statistical comparison performed for each time point. Each ELISA was performed according to the instructions within each kit...expectations for controls. Results of osteocalcin ELISA were evaluated and any results with a coefficient of variation greater than 25% were omitted...Results of TRAP5b ELISA were evaluated and any results with a coefficient of variation greater than 25% were omitted from analysis. Measures of TRAP5b
Cost analysis of hospital material management systems.
Egbelu, P J; Harmonosky, C M; Ventura, J A; O'Brien, W E; Sommer, H J
1998-01-01
Integrated healthcare material management begins with manufactures of medical/surgical supplies, uses distributors and ends at the point of use at hospitals. Recent material management philosophies in the healthcare industry, such as just-in-time and stockless systems, are yet to be fully evaluated. In order to evaluate the cost effectiveness of each type of material management technique, a cost model for hospital materials management has been designed. Several case scenarios are analyzed and results are reported.
Longitudinal Multiple Sclerosis Lesion Segmentation: Resource & Challenge
Carass, Aaron; Roy, Snehashis; Jog, Amod; Cuzzocreo, Jennifer L.; Magrath, Elizabeth; Gherman, Adrian; Button, Julia; Nguyen, James; Prados, Ferran; Sudre, Carole H.; Cardoso, Manuel Jorge; Cawley, Niamh; Ciccarelli, Olga; Wheeler-Kingshott, Claudia A. M.; Ourselin, Sébastien; Catanese, Laurence; Deshpande, Hrishikesh; Maurel, Pierre; Commowick, Olivier; Barillot, Christian; Tomas-Fernandez, Xavier; Warfield, Simon K.; Vaidya, Suthirth; Chunduru, Abhijith; Muthuganapathy, Ramanathan; Krishnamurthi, Ganapathy; Jesson, Andrew; Arbel, Tal; Maier, Oskar; Handels, Heinz; Iheme, Leonardo O.; Unay, Devrim; Jain, Saurabh; Sima, Diana M.; Smeets, Dirk; Ghafoorian, Mohsen; Platel, Bram; Birenbaum, Ariel; Greenspan, Hayit; Bazin, Pierre-Louis; Calabresi, Peter A.; Crainiceanu, Ciprian M.; Ellingsen, Lotta M.; Reich, Daniel S.; Prince, Jerry L.; Pham, Dzung L.
2017-01-01
In conjunction with the ISBI 2015 conference, we organized a longitudinal lesion segmentation challenge providing training and test data to registered participants. The training data consisted of five subjects with a mean of 4.4 time-points, and test data of fourteen subjects with a mean of 4.4 time-points. All 82 data sets had the white matter lesions associated with multiple sclerosis delineated by two human expert raters. Eleven teams submitted results using state-of-the-art lesion segmentation algorithms to the challenge, with ten teams presenting their results at the conference. We present a quantitative evaluation comparing the consistency of the two raters as well as exploring the performance of the eleven submitted results in addition to three other lesion segmentation algorithms. The challenge presented three unique opportunities: 1) the sharing of a rich data set; 2) collaboration and comparison of the various avenues of research being pursued in the community; and 3) a review and refinement of the evaluation metrics currently in use. We report on the performance of the challenge participants, as well as the construction and evaluation of a consensus delineation. The image data and manual delineations will continue to be available for download, through an evaluation website1 as a resource for future researchers in the area. This data resource provides a platform to compare existing methods in a fair and consistent manner to each other and multiple manual raters. PMID:28087490
Mekenyan, Ovanes; Patlewicz, Grace; Dimitrova, Gergana; Kuseva, Chanita; Todorov, Milen; Stoeva, Stoyanka; Kotov, Stefan; Donner, E Maria
2010-10-18
Skin sensitization is an end point of concern for various legislation in the EU, including the seventh Amendment to the Cosmetics Directive and Registration Evaluation, Authorisation and Restriction of Chemicals (REACH). Since animal testing is a last resort for REACH or banned (from 2013 onward) for the Cosmetics Directive, the use of intelligent/integrated testing strategies (ITS) as an efficient means of gathering necessary information from alternative sources (e.g., in vitro, (Q)SARs, etc.) is gaining widespread interest. Previous studies have explored correlations between mutagenicity data and skin sensitization data as a means of exploiting information from surrogate end points. The work here compares the underlying chemical mechanisms for mutagenicity and skin sensitization in an effort to evaluate the role mutagenicity information can play as a predictor of skin sensitization potential. The Tissue Metabolism Simulator (TIMES) hybrid expert system was used to compare chemical mechanisms of both end points since it houses a comprehensive set of established structure-activity relationships for both skin sensitization and mutagenicity. The evaluation demonstrated that there is a great deal of overlap between skin sensitization and mutagenicity structural alerts and their underlying chemical mechanisms. The similarities and differences in chemical mechanisms are discussed in light of available experimental data. A number of new alerts for mutagenicity were also postulated for inclusion into TIMES. The results presented show that mutagenicity information can provide useful insights on skin sensitization potential as part of an ITS and should be considered prior to any in vivo skin sensitization testing being initiated.
Biomechanical and Histologic Evaluation of LifeMesh™: A Novel Self-Fixating Mesh Adhesive.
Shahan, Charles P; Stoikes, Nathaniel N; Roan, Esra; Tatum, James; Webb, David L; Voeller, Guy R
2018-04-01
Mesh fixation with the use of adhesives results in an immediate and total surface area adhesion of the mesh, removing the need for penetrating fixation points. The purpose of this study was to evaluate LifeMesh™, a prototype mesh adhesive technology which coats polypropylene mesh. The strength of the interface between mesh and tissue, inflammatory responses, and histology were measured at varying time points in a swine model, and these results were compared with sutures. Twenty Mongrel swine underwent implantation of LifeMesh™ and one piece of bare polypropylene mesh secured with suture (control). One additional piece of either LifeMesh™ or control was used for histopathologic evaluation. The implants were retrieved at 3, 7, and 14 days. Only 3- and 7-day specimens underwent lap shear testing. On Day 3, LifeMesh™ samples showed considerably less contraction than sutured samples. The interfacial strength of Day 3 LifeMesh™ samples was similar to that of sutured samples. At seven days, LifeMesh™ samples continued to show significantly less contraction than sutured samples. The strength of fixation at seven days was greater in the control samples. The histologic findings were similar in LifeMesh™ and control samples. LifeMesh™ showed significantly less contraction than sutured samples at all measured time points. Although fixation strength was similar at three days, the interfacial strength of LifeMesh™ remained unchanged, whereas sutured controls increased by day 7. With histologic equivalence, considerably less contraction, and similar early fixation strength, LifeMesh™ is a viable mesh fixation technology.
NASA Astrophysics Data System (ADS)
Balaji, K. A.; Prabu, K.
2018-03-01
There is an immense demand for high bandwidth and high data rate systems, which is fulfilled by wireless optical communication or free space optics (FSO). Hence FSO gained a pivotal role in research which has a added advantage of both cost-effective and licence free huge bandwidth. Unfortunately the optical signal in free space suffers from irradiance and phase fluctuations due to atmospheric turbulence and pointing errors which deteriorates the signal and degrades the performance of communication system over longer distance which is undesirable. In this paper, we have considered polarization shift keying (POLSK) system applied with wavelength and time diversity technique over Malaga(M)distribution to mitigate turbulence induced fading. We derived closed form mathematical expressions for estimating the systems outage probability and average bit error rate (BER). Ultimately from the results we can infer that wavelength and time diversity schemes enhances these systems performance.
Identification of bearing faults using time domain zero-crossings
NASA Astrophysics Data System (ADS)
William, P. E.; Hoffman, M. W.
2011-11-01
In this paper, zero-crossing characteristic features are employed for early detection and identification of single point bearing defects in rotating machinery. As a result of bearing defects, characteristic defect frequencies appear in the machine vibration signal, normally requiring spectral analysis or envelope analysis to identify the defect type. Zero-crossing features are extracted directly from the time domain vibration signal using only the duration between successive zero-crossing intervals and do not require estimation of the rotational frequency. The features are a time domain representation of the composite vibration signature in the spectral domain. Features are normalized by the length of the observation window and classification is performed using a multilayer feedforward neural network. The model was evaluated on vibration data recorded using an accelerometer mounted on an induction motor housing subjected to a number of single point defects with different severity levels.
Time-dependent efficacy of longitudinal biomarker for clinical endpoint.
Kolamunnage-Dona, Ruwanthi; Williamson, Paula R
2018-06-01
Joint modelling of longitudinal biomarker and event-time processes has gained its popularity in recent years as they yield more accurate and precise estimates. Considering this modelling framework, a new methodology for evaluating the time-dependent efficacy of a longitudinal biomarker for clinical endpoint is proposed in this article. In particular, the proposed model assesses how well longitudinally repeated measurements of a biomarker over various time periods (0,t) distinguish between individuals who developed the disease by time t and individuals who remain disease-free beyond time t. The receiver operating characteristic curve is used to provide the corresponding efficacy summaries at various t based on the association between longitudinal biomarker trajectory and risk of clinical endpoint prior to each time point. The model also allows detecting the time period over which a biomarker should be monitored for its best discriminatory value. The proposed approach is evaluated through simulation and illustrated on the motivating dataset from a prospective observational study of biomarkers to diagnose the onset of sepsis.
Assessing blood coagulation status with laser speckle rheology
Tripathi, Markandey M.; Hajjarian, Zeinab; Van Cott, Elizabeth M.; Nadkarni, Seemantini K.
2014-01-01
We have developed and investigated a novel optical approach, Laser Speckle Rheology (LSR), to evaluate a patient’s coagulation status by measuring the viscoelastic properties of blood during coagulation. In LSR, a blood sample is illuminated with laser light and temporal speckle intensity fluctuations are measured using a high-speed CMOS camera. During blood coagulation, changes in the viscoelastic properties of the clot restrict Brownian displacements of light scattering centers within the sample, altering the rate of speckle intensity fluctuations. As a result, blood coagulation status can be measured by relating the time scale of speckle intensity fluctuations with clinically relevant coagulation metrics including clotting time and fibrinogen content. Our results report a close correlation between coagulation metrics measured using LSR and conventional coagulation results of activated partial thromboplastin time, prothrombin time and functional fibrinogen levels, creating the unique opportunity to evaluate a patient’s coagulation status in real-time at the point of care. PMID:24688816
2008-01-01
Objective To compare optical coherence tomography (OCT)-measured retinal thickness and visual acuity in eyes with diabetic macular edema (DME) both before and after macular laser photocoagulation. Design Cross-sectional and longitudinal study. Participants 210 subjects (251 eyes) with DME enrolled in a randomized clinical trial of laser techniques. Methods Retinal thickness was measured with OCT and visual acuity was measured with the electronic-ETDRS procedure. Main Outcome Measures OCT-measured center point thickness and visual acuity Results The correlation coefficients for visual acuity versus OCT center point thickness were 0.52 at baseline and 0.49, 0.36, and 0.38 at 3.5, 8, and 12 months post-laser photocoagulation. The slope of the best fit line to the baseline data was approximately 4.4 letters (95% C.I.: 3.5, 5.3) better visual acuity for every 100 microns decrease in center point thickness at baseline with no important difference at follow-up visits. Approximately one-third of the variation in visual acuity could be predicted by a linear regression model that incorporated OCT center point thickness, age, hemoglobin A1C, and severity of fluorescein leakage in the center and inner subfields. The correlation between change in visual acuity and change in OCT center point thickening 3.5 months after laser treatment was 0.44 with no important difference at the other follow-up times. A subset of eyes showed paradoxical improvements in visual acuity with increased center point thickening (7–17% at the three time points) or paradoxical worsening of visual acuity with a decrease in center point thickening (18%–26% at the three time points). Conclusions There is modest correlation between OCT-measured center point thickness and visual acuity, and modest correlation of changes in retinal thickening and visual acuity following focal laser treatment for DME. However, a wide range of visual acuity may be observed for a given degree of retinal edema and paradoxical increases in center point thickening with increases in visual acuity as well as paradoxical decreases in center point thickening with decreases in visual acuity were not uncommon. Thus, although OCT measurements of retinal thickness represent an important tool in clinical evaluation, they cannot reliably substitute as a surrogate for visual acuity at a given point in time. This study does not address whether short-term changes on OCT are predictive of long-term effects on visual acuity. PMID:17123615
Homogenising time series: Beliefs, dogmas and facts
NASA Astrophysics Data System (ADS)
Domonkos, P.
2010-09-01
For obtaining reliable information about climate change and climate variability the use of high quality data series is essentially important, and one basic tool of quality improvements is the statistical homogenisation of observed time series. In the recent decades large number of homogenisation methods has been developed, but the real effects of their application on time series are still not known entirely. The ongoing COST HOME project (COST ES0601) is devoted to reveal the real impacts of homogenisation methods more detailed and with higher confidence than earlier. As part of the COST activity, a benchmark dataset was built whose characteristics approach well the characteristics of real networks of observed time series. This dataset offers much better opportunity than ever to test the wide variety of homogenisation methods, and analyse the real effects of selected theoretical recommendations. The author believes that several old theoretical rules have to be re-evaluated. Some examples of the hot questions, a) Statistically detected change-points can be accepted only with the confirmation of metadata information? b) Do semi-hierarchic algorithms for detecting multiple change-points in time series function effectively in practise? c) Is it good to limit the spatial comparison of candidate series with up to five other series in the neighbourhood? Empirical results - those from the COST benchmark, and other experiments too - show that real observed time series usually include several inhomogeneities of different sizes. Small inhomogeneities seem like part of the climatic variability, thus the pure application of classic theory that change-points of observed time series can be found and corrected one-by-one is impossible. However, after homogenisation the linear trends, seasonal changes and long-term fluctuations of time series are usually much closer to the reality, than in raw time series. The developers and users of homogenisation methods have to bear in mind that the eventual purpose of homogenisation is not to find change-points, but to have the observed time series with statistical properties those characterise well the climate change and climate variability.
Developing R&D portfolio business validity simulation model and system.
Yeo, Hyun Jin; Im, Kwang Hyuk
2015-01-01
The R&D has been recognized as critical method to take competitiveness by not only companies but also nations with its value creation such as patent value and new product. Therefore, R&D has been a decision maker's burden in that it is hard to decide how much money to invest, how long time one should spend, and what technology to develop which means it accompanies resources such as budget, time, and manpower. Although there are diverse researches about R&D evaluation, business factors are not concerned enough because almost all previous studies are technology oriented evaluation with one R&D technology based. In that, we early proposed R&D business aspect evaluation model which consists of nine business model components. In this research, we develop a simulation model and system evaluating a company or industry's R&D portfolio with business model point of view and clarify default and control parameters to facilitate evaluator's business validity work in each evaluation module by integrate to one screen.
Developing R&D Portfolio Business Validity Simulation Model and System
2015-01-01
The R&D has been recognized as critical method to take competitiveness by not only companies but also nations with its value creation such as patent value and new product. Therefore, R&D has been a decision maker's burden in that it is hard to decide how much money to invest, how long time one should spend, and what technology to develop which means it accompanies resources such as budget, time, and manpower. Although there are diverse researches about R&D evaluation, business factors are not concerned enough because almost all previous studies are technology oriented evaluation with one R&D technology based. In that, we early proposed R&D business aspect evaluation model which consists of nine business model components. In this research, we develop a simulation model and system evaluating a company or industry's R&D portfolio with business model point of view and clarify default and control parameters to facilitate evaluator's business validity work in each evaluation module by integrate to one screen. PMID:25893209
Impacts of Satellite Orbit and Clock on Real-Time GPS Point and Relative Positioning.
Shi, Junbo; Wang, Gaojing; Han, Xianquan; Guo, Jiming
2017-06-12
Satellite orbit and clock corrections are always treated as known quantities in GPS positioning models. Therefore, any error in the satellite orbit and clock products will probably cause significant consequences for GPS positioning, especially for real-time applications. Currently three types of satellite products have been made available for real-time positioning, including the broadcast ephemeris, the International GNSS Service (IGS) predicted ultra-rapid product, and the real-time product. In this study, these three predicted/real-time satellite orbit and clock products are first evaluated with respect to the post-mission IGS final product, which demonstrates cm to m level orbit accuracies and sub-ns to ns level clock accuracies. Impacts of real-time satellite orbit and clock products on GPS point and relative positioning are then investigated using the P3 and GAMIT software packages, respectively. Numerical results show that the real-time satellite clock corrections affect the point positioning more significantly than the orbit corrections. On the contrary, only the real-time orbit corrections impact the relative positioning. Compared with the positioning solution using the IGS final product with the nominal orbit accuracy of ~2.5 cm, the real-time broadcast ephemeris with ~2 m orbit accuracy provided <2 cm relative positioning error for baselines no longer than 216 km. As for the baselines ranging from 574 to 2982 km, the cm-dm level positioning error was identified for the relative positioning solution using the broadcast ephemeris. The real-time product could result in <5 mm relative positioning accuracy for baselines within 2982 km, slightly better than the predicted ultra-rapid product.
Schooler, J; Kumar, D; Nardo, L; McCulloch, C; Li, X; Link, T M; Majumdar, S
2014-01-01
To investigate longitudinal changes in laminar and spatial distribution of knee articular cartilage magnetic resonance imaging (MRI) T1ρ and T2 relaxation times, in individuals with and without medial compartment cartilage defects. All subjects (at baseline n = 88, >18 years old) underwent 3-Tesla knee MRI at baseline and annually thereafter for 3 years. The MR studies were evaluated for presence of cartilage defects (modified Whole-Organ Magnetic Resonance Imaging Scoring - mWORMS), and quantitative T1ρ and T2 relaxation time maps. Subjects were segregated into those with (mWORMS ≥2) and without (mWORMS ≤1) cartilage lesions at the medial tibia (MT) or medial femur (MF) at each time point. Laminar (bone and articular layer) and spatial (gray level co-occurrence matrix - GLCM) distribution of the T1ρ and T2 relaxation time maps were calculated. Linear regression models (cross-sectional) and Generalized Estimating Equations (GEEs) (longitudinal) were used. Global T1ρ, global T2 and articular layer T2 relaxation times at the MF, and global and articular layer T2 relaxation times at the MT, were higher in subjects with cartilage lesions compared to those without lesions. At the MT global T1ρ relaxation times were higher at each time point in subjects with lesions. MT T1ρ and T2 became progressively more heterogeneous than control compartments over the course of the study. Spatial distribution of T1ρ and T2 relaxation time maps in medial knee OA using GLCM technique may be a sensitive indicator of cartilage deterioration, in addition to whole-compartment relaxation time data. Copyright © 2013 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Safe driving and executive functions in healthy middle-aged drivers.
León-Domínguez, Umberto; Solís-Marcos, Ignacio; Barrio-Álvarez, Elena; Barroso Y Martín, Juan Manuel; León-Carrión, José
2017-01-01
The introduction of the point system driver's license in several European countries could offer a valid framework for evaluating driving skills. This is the first study to use this framework to assess the functional integrity of executive functions in middle-aged drivers with full points, partial points or no points on their driver's license (N = 270). The purpose of this study is to find differences in executive functions that could be determinants in safe driving. Cognitive tests were used to assess attention processes, processing speed, planning, cognitive flexibility, and inhibitory control. Analyses for covariance (ANCOVAS) were used for group comparisons while adjusting for education level. The Bonferroni method was used for correcting for multiple comparisons. Overall, drivers with the full points on their license showed better scores than the other two groups. In particular, significant differences were found in reaction times on Simple and Conditioned Attention tasks (both p-values < 0.001) and in number of type-III errors on the Tower of Hanoi task (p = 0.026). Differences in reaction time on attention tasks could serve as neuropsychological markers for safe driving. Further analysis should be conducted in order to determine the behavioral impact of impaired executive functioning on driving ability.
Preconditioning 2D Integer Data for Fast Convex Hull Computations
2016-01-01
In order to accelerate computing the convex hull on a set of n points, a heuristic procedure is often applied to reduce the number of points to a set of s points, s ≤ n, which also contains the same hull. We present an algorithm to precondition 2D data with integer coordinates bounded by a box of size p × q before building a 2D convex hull, with three distinct advantages. First, we prove that under the condition min(p, q) ≤ n the algorithm executes in time within O(n); second, no explicit sorting of data is required; and third, the reduced set of s points forms a simple polygonal chain and thus can be directly pipelined into an O(n) time convex hull algorithm. This paper empirically evaluates and quantifies the speed up gained by preconditioning a set of points by a method based on the proposed algorithm before using common convex hull algorithms to build the final hull. A speedup factor of at least four is consistently found from experiments on various datasets when the condition min(p, q) ≤ n holds; the smaller the ratio min(p, q)/n is in the dataset, the greater the speedup factor achieved. PMID:26938221
Day, Douglas G; Walters, Thomas R; Schwartz, Gail F; Mundorf, Thomas K; Liu, Charlie; Schiffman, Rhett M; Bejanian, Marina
2013-01-01
Background/Aim To evaluate efficacy and safety of bimatoprost 0.03% preservative-free (PF) ophthalmic solution versus bimatoprost 0.03% (Lumigan) ophthalmic solution for glaucoma or ocular hypertension. Methods In this double-masked, parallel-group study, patients were randomised to bimatoprost PF or bimatoprost for 12 weeks. The primary analysis for non-inferiority was change from baseline in worse eye intraocular pressure (IOP) in the per-protocol population at week 12. For equivalence, it was average eye IOP in the intent-to-treat population at each time point at weeks 2, 6 and 12. Results 597 patients were randomised (bimatoprost PF, n=302 and bimatoprost, n=295). The 95% CI upper limit for worse eye IOP change from baseline was <1.5 mm Hg at each week 12 time point, meeting prespecified non-inferiority criteria. The 95% CI upper limit for the treatment difference for average IOP was 0.69 mm Hg and the lower limit was −0.50 mm Hg at all follow-up time points (hours 0, 2 and 8 at weeks 2, 6 and 12), meeting equivalence criteria. Both treatments showed decreases in mean average eye IOP at all follow-up time points (p<0.001), were safe and well tolerated. Conclusions Bimatoprost PF is non-inferior and equivalent to bimatoprost in its ability to reduce IOP-lowering with a safety profile similar to bimatoprost. PMID:23743437
NASA Astrophysics Data System (ADS)
Lopez, Benjamin; Baran, Nicole; Bourgine, Bernard
2015-03-01
The European Water Framework Directive (WFD) asks Member States to identify trends in contaminant concentrations in groundwater and to take measures to reach a good chemical status by 2015. In this study, carried out in a large hydrological basin (95,300 km2), an innovative procedure is described for the assessment of recent trends in groundwater nitrate concentrations both at sampling point and regional scales. Temporal variograms of piezometric and nitrate concentration time series are automatically calculated and fitted in order to classify groundwater according to their temporal pattern. These results are then coupled with aquifer lithology to map spatial units within which the modes of diffuse transport of contaminants towards groundwater are assumed to be the same at all points. These spatial units are suitable for evaluating regional trends. The stability over time of the time series is tested based on the cumulative sum principle, to determine the time period during which the trend should be sought. The Mann-Kendall and Regional-Kendall nonparametric tests for monotonic trends, coupled with the Sen-slope test, are applied to the periods following the point breaks thus determined at both the sampling point or regional scales. This novel procedure is robust and enables rapid processing of large databases of raw data. It would therefore be useful for managing groundwater quality in compliance with the aims of the WFD.
Madan, Renu; Pathy, Sushmita; Subramani, Vellaiyan; Sharma, Seema; Mohanti, Bidhu Kalyan; Chander, Subhash; Thulkar, Sanjay; Kumar, Lalit; Dadhwal, Vatsla
2014-01-01
Dosimetric comparison of two dimensional (2D) radiography and three-dimensional computed tomography (3D-CT) based dose distributions with high-dose-rate (HDR) intracavitry radiotherapy (ICRT) for carcinoma cervix, in terms of target coverage and doses to bladder and rectum. Sixty four sessions of HDR ICRT were performed in 22 patients. External beam radiotherapy to pelvis at a dose of 50 Gray in 27 fractions followed by HDR ICRT, 21 Grays to point A in 3 sessions, one week apart was planned . All patients underwent 2D-orthogonal and 3D-CT simulation for each session. Treatment plans were generated using 2D-orthogonal images and dose prescription was made at point A. 3D plans were generated using 3D-CT images after delineating target volume and organs at risk. Comparative evaluation of 2D and 3D treatment planning was made for each session in terms of target coverage (dose received by 90%, 95% and 100% of the target volume: D90, D95 and D100 respectively) and doses to bladder and rectum: ICRU-38 bladder and rectum point dose in 2D planning and dose to 0.1cc, 1cc, 2cc, 5cc, and 10cc of bladder and rectum in 3D planning. Mean doses received by 100% and 90% of the target volume were 4.24 ± 0.63 and 4.9 ± 0.56 Gy respectively. Doses received by 0.1cc, 1cc and 2cc volume of bladder were 2.88 ± 0.72, 2.5 ± 0.65 and 2.2 ± 0.57 times more than the ICRU bladder reference point. Similarly, doses received by 0.1cc, 1cc and 2cc of rectum were 1.80 ± 0.5, 1.48 ± 0.41 and 1.35 ± 0.37 times higher than ICRU rectal reference point. Dosimetric comparative evaluation of 2D and 3D CT based treatment planning for the same brachytherapy session demonstrates underestimation of OAR doses and overestimation of target coverage in 2D treatment planning.
NASA Astrophysics Data System (ADS)
Oh, Gyong Jin; Kim, Lyang-June; Sheen, Sue-Ho; Koo, Gyou-Phyo; Jin, Sang-Hun; Yeo, Bo-Yeon; Lee, Jong-Ho
2009-05-01
This paper presents a real time implementation of Non Uniformity Correction (NUC). Two point correction and one point correction with shutter were carried out in an uncooled imaging system which will be applied to a missile application. To design a small, light weight and high speed imaging system for a missile system, SoPC (System On a Programmable Chip) which comprises of FPGA and soft core (Micro-blaze) was used. Real time NUC and generation of control signals are implemented using FPGA. Also, three different NUC tables were made to make the operating time shorter and to reduce the power consumption in a large range of environment temperature. The imaging system consists of optics and four electronics boards which are detector interface board, Analog to Digital converter board, Detector signal generation board and Power supply board. To evaluate the imaging system, NETD was measured. The NETD was less than 160mK in three different environment temperatures.
Peyrat, Jean-Marc; Delingette, Hervé; Sermesant, Maxime; Xu, Chenyang; Ayache, Nicholas
2010-07-01
We propose a framework for the nonlinear spatiotemporal registration of 4D time-series of images based on the Diffeomorphic Demons (DD) algorithm. In this framework, the 4D spatiotemporal registration is decoupled into a 4D temporal registration, defined as mapping physiological states, and a 4D spatial registration, defined as mapping trajectories of physical points. Our contribution focuses more specifically on the 4D spatial registration that should be consistent over time as opposed to 3D registration that solely aims at mapping homologous points at a given time-point. First, we estimate in each sequence the motion displacement field, which is a dense representation of the point trajectories we want to register. Then, we perform simultaneously 3D registrations of corresponding time-points with the constraints to map the same physical points over time called the trajectory constraints. Under these constraints, we show that the 4D spatial registration can be formulated as a multichannel registration of 3D images. To solve it, we propose a novel version of the Diffeomorphic Demons (DD) algorithm extended to vector-valued 3D images, the Multichannel Diffeomorphic Demons (MDD). For evaluation, this framework is applied to the registration of 4D cardiac computed tomography (CT) sequences and compared to other standard methods with real patient data and synthetic data simulated from a physiologically realistic electromechanical cardiac model. Results show that the trajectory constraints act as a temporal regularization consistent with motion whereas the multichannel registration acts as a spatial regularization. Finally, using these trajectory constraints with multichannel registration yields the best compromise between registration accuracy, temporal and spatial smoothness, and computation times. A prospective example of application is also presented with the spatiotemporal registration of 4D cardiac CT sequences of the same patient before and after radiofrequency ablation (RFA) in case of atrial fibrillation (AF). The intersequence spatial transformations over a cardiac cycle allow to analyze and quantify the regression of left ventricular hypertrophy and its impact on the cardiac function.
Evaluation of thermal network correction program using test temperature data
NASA Technical Reports Server (NTRS)
Ishimoto, T.; Fink, L. C.
1972-01-01
An evaluation process to determine the accuracy of a computer program for thermal network correction is discussed. The evaluation is required since factors such as inaccuracies of temperatures, insufficient number of temperature points over a specified time period, lack of one-to-one correlation between temperature sensor and nodal locations, and incomplete temperature measurements are not present in the computer-generated information. The mathematical models used in the evaluation are those that describe a physical system composed of both a conventional and a heat pipe platform. A description of the models used, the results of the evaluation of the thermal network correction, and input instructions for the thermal network correction program are presented.
Tracking Voice Change after Thyroidectomy: Application of Spectral/Cepstral Analyses
ERIC Educational Resources Information Center
Awan, Shaheen N.; Helou, Leah B.; Stojadinovic, Alexander; Solomon, Nancy Pearl
2011-01-01
This study evaluates the utility of perioperative spectral and cepstral acoustic analyses to monitor voice change after thyroidectomy. Perceptual and acoustic analyses were conducted on speech samples (sustained vowel /[alpha]/ and CAPE-V sentences) provided by 70 participants (36 women and 34 men) at four study time points: prior to thyroid…
Laser biostimulation in treatment of actinomycosis
NASA Astrophysics Data System (ADS)
Grzesiak-Janas, Grazyna; Janas, Anna
2003-10-01
Biostimulative laser therapy was used in 4 patients with actinomycosis. In each patient extraoral radiation by means of the "contact point" method was applied. The results were evaluated on the basis of clinical and bacteriological examinations. Laserotherapy had a beneficial effect on the course of treatment of actinomycosis and shortened the time of curing.
2015-07-16
outcome or training benefit the DoD/USAF? Yes. This study provided evidence that extracellular matrix made from swine small intestinal submucosa does...Isometric functional testing was implemented prior to euthanasia 2 FDGXXX at 10 months to further evaluate healing at later time points
Analyses of biomarkers in fish were used to evaluate exposures among locations and across time. Two types of references were used for comparison, an upstream reference sample remote from known point sources and regional exposure criteria derived from a baseline of fish from refer...
Evaluation of the Recognizing and Responding to Suicide Risk Training
ERIC Educational Resources Information Center
Jacobson, Jodi Michelle; Osteen, Philip; Jones, Andrea; Berman, Alan
2012-01-01
Changes in attitudes, confidence, and practice behaviors were assessed among 452 clinicians who completed the training, Recognizing and Responding to Suicide Risk, and who work with clients at risk for suicide. Data were collected at three time points. Scores on measures of attitudes toward suicide prevention and confidence to work with clients at…
The effect of the synthetic pyrethroid flucythrinate on three non-target invertebrates was evaluated using continual and short-time exposure methods. Both methods show toxic action at measured concentrations 0.100 micrograms/litre. The use of both approaches pointed toward the im...
Longitudinal Stability of the Leadership Scale for Sports
ERIC Educational Resources Information Center
Fletcher, Richard B.; Roberts, Margaret H.
2013-01-01
This study evaluated the invariance properties of the Leadership Scale for Sport in a sample of 219 female netball players over four time points within a 10-week playing season. Support was found for Chelladurai and Saleh's (1980) hypothesized 5-factor structure of the Leadership Scale for Sport. Furthermore, differential stability and partial…
Effect of mixing time and speed on experimental baking and dough testing with a 200g pin-mixer
USDA-ARS?s Scientific Manuscript database
Under mixing or over mixing the dough results in varied experimental loaf volumes. Bread preparation requires a trained baker to evaluate dough development and determine stop points of mixer. Instrumentation and electronic control of the dough mixer would allow for automatic mixing. This study us...
Point Cloud-Based Automatic Assessment of 3D Computer Animation Courseworks
ERIC Educational Resources Information Center
Paravati, Gianluca; Lamberti, Fabrizio; Gatteschi, Valentina; Demartini, Claudio; Montuschi, Paolo
2017-01-01
Computer-supported assessment tools can bring significant benefits to both students and teachers. When integrated in traditional education workflows, they may help to reduce the time required to perform the evaluation and consolidate the perception of fairness of the overall process. When integrated within on-line intelligent tutoring systems,…
Readerbench: Automated Evaluation of Collaboration Based on Cohesion and Dialogism
ERIC Educational Resources Information Center
Dascalu, Mihai; Trausan-Matu, Stefan; McNamara, Danielle S.; Dessus, Philippe
2015-01-01
As Computer-Supported Collaborative Learning (CSCL) gains a broader usage, the need for automated tools capable of supporting tutors in the time-consuming process of analyzing conversations becomes more pressing. Moreover, collaboration, which presumes the intertwining of ideas or points of view among participants, is a central element of dialogue…
Analyses of biomarkers in fish were used to evaluate exposures among locations and across time. Two types of references were used for comparison, an upstream reference sample remote from known point sources and regional exposure criteria derived from a basline of fish from refere...
ERIC Educational Resources Information Center
Porter, Kristin E.
2018-01-01
Researchers are often interested in testing the effectiveness of an intervention on multiple outcomes, for multiple subgroups, at multiple points in time, or across multiple treatment groups. The resulting multiplicity of statistical hypothesis tests can lead to spurious findings of effects. Multiple testing procedures (MTPs) are statistical…
Komorkiewicz, Mateusz; Kryjak, Tomasz; Gorgon, Marek
2014-01-01
This article presents an efficient hardware implementation of the Horn-Schunck algorithm that can be used in an embedded optical flow sensor. An architecture is proposed, that realises the iterative Horn-Schunck algorithm in a pipelined manner. This modification allows to achieve data throughput of 175 MPixels/s and makes processing of Full HD video stream (1, 920 × 1, 080 @ 60 fps) possible. The structure of the optical flow module as well as pre- and post-filtering blocks and a flow reliability computation unit is described in details. Three versions of optical flow modules, with different numerical precision, working frequency and obtained results accuracy are proposed. The errors caused by switching from floating- to fixed-point computations are also evaluated. The described architecture was tested on popular sequences from an optical flow dataset of the Middlebury University. It achieves state-of-the-art results among hardware implementations of single scale methods. The designed fixed-point architecture achieves performance of 418 GOPS with power efficiency of 34 GOPS/W. The proposed floating-point module achieves 103 GFLOPS, with power efficiency of 24 GFLOPS/W. Moreover, a 100 times speedup compared to a modern CPU with SIMD support is reported. A complete, working vision system realized on Xilinx VC707 evaluation board is also presented. It is able to compute optical flow for Full HD video stream received from an HDMI camera in real-time. The obtained results prove that FPGA devices are an ideal platform for embedded vision systems. PMID:24526303
Lin, Min; Xu, XiaoWen; Wang, Yi; Hu, Yue; Zhao, Yu
2014-01-01
To evaluate the use of a levonorgestrel-releasing intrauterine system (LNG-IUS) for treating endometrial hyperplasia in patients with polycystic ovary syndrome (PCOS). LNG-IUSs were inserted in 60 PCOS patients with simple (40 cases), irregular (12 cases), or complex (8 cases) endometrial hyperplasia. Follow-ups were performed at 3, 6, 12, and 24 months after insertion. At each time point, changes in menstruation, hemoglobin level, and endometrial thickness and pathology were recorded. Menstrual changes were assessed with the Pictorial Blood Assessment Chart. Hemoglobin levels were measured by the Blood Routine Test. Endometrial thickness was determined by transvaginal ultrasound. Endometrial pathology was defined as simple, irregular, or complex endometrial hyperplasia by a pathologist after curettage. Outcomes at each time point were compared to baseline (pre-insertion) measurements by Student's t test or ANOVA (for multiple comparisons) with the post hoc Dunnett's test. Differences with a p < 0.05 were considered statistically significant. At all time points after LNG-IUS insertion and in all patients, menstrual blood loss was decreased and hemoglobin level was increased significantly compared to pre-insertion levels. The endometrial thickness was significantly reduced in all groups after 12 months. Most patients showed transformation of the endometrial pathology, with complete disappearance of simple and irregular cases of endometrial hyperplasia and a decreased number of complex endometrial hyperplasia cases. LNG-IUS is an effective, safe, nonsurgical, and atraumatic approach with few side effects for the treatment of endometrial hyperplasia in patients with PCOS. © 2014 S. Karger AG, Basel.
Komorkiewicz, Mateusz; Kryjak, Tomasz; Gorgon, Marek
2014-02-12
This article presents an efficient hardware implementation of the Horn-Schunck algorithm that can be used in an embedded optical flow sensor. An architecture is proposed, that realises the iterative Horn-Schunck algorithm in a pipelined manner. This modification allows to achieve data throughput of 175 MPixels/s and makes processing of Full HD video stream (1; 920 × 1; 080 @ 60 fps) possible. The structure of the optical flow module as well as pre- and post-filtering blocks and a flow reliability computation unit is described in details. Three versions of optical flow modules, with different numerical precision, working frequency and obtained results accuracy are proposed. The errors caused by switching from floating- to fixed-point computations are also evaluated. The described architecture was tested on popular sequences from an optical flow dataset of the Middlebury University. It achieves state-of-the-art results among hardware implementations of single scale methods. The designed fixed-point architecture achieves performance of 418 GOPS with power efficiency of 34 GOPS/W. The proposed floating-point module achieves 103 GFLOPS, with power efficiency of 24 GFLOPS/W. Moreover, a 100 times speedup compared to a modern CPU with SIMD support is reported. A complete, working vision system realized on Xilinx VC707 evaluation board is also presented. It is able to compute optical flow for Full HD video stream received from an HDMI camera in real-time. The obtained results prove that FPGA devices are an ideal platform for embedded vision systems.
Belanger, Heather G; Lange, Rael T; Bailie, Jason; Iverson, Grant L; Arrieux, Jacques P; Ivins, Brian J; Cole, Wesley R
2016-10-01
The purpose of this study was to examine the prevalence and stability of symptom reporting in a healthy military sample and to develop reliable change indices for two commonly used self-report measures in the military health care system. Participants were 215 U.S. active duty service members recruited from Fort Bragg, NC as normal controls as part of a larger study. Participants completed the Neurobehavioral Symptom Inventory (NSI) and Posttraumatic Checklist (PCL) twice, separated by approximately 30 days. Depending on the endorsement level used (i.e. ratings of 'mild' or greater vs. ratings of 'moderate' or greater), approximately 2-15% of this sample met DSM-IV symptom criteria for Postconcussional Disorder across time points, while 1-6% met DSM-IV symptom criteria for Posttraumatic Stress Disorder. Effect sizes for change from Time 1 to Time 2 on individual symptoms were small (Cohen's d = .01 to .13). The test-retest reliability for the NSI total score was r = .78 and the PCL score was r = .70. An eight-point change in symptom reporting represented reliable change on the NSI total score, with a seven-point change needed on the PCL. Postconcussion-like symptoms are not unique to mild TBI and are commonly reported in a healthy soldier sample. It is important for clinicians to use normative data when evaluating a service member or veteran and when evaluating the likelihood that a change in symptom reporting is reliable and clinically meaningful.
Economic and microbiologic evaluation of single-dose vial extension for hazardous drugs.
Rowe, Erinn C; Savage, Scott W; Rutala, William A; Weber, David J; Gergen-Teague, Maria; Eckel, Stephen F
2012-07-01
The update of US Pharmacopeia Chapter <797> in 2008 included guidelines stating that single-dose vials (SDVs) opened and maintained in an International Organization for Standardization Class 5 environment can be used for up to 6 hours after initial puncture. A study was conducted to evaluate the cost of discarding vials after 6 hours and to further test sterility of vials beyond this time point, subsequently defined as the beyond-use date (BUD). Financial determination of SDV waste included 2 months of retrospective review of all doses prescribed. Additionally, actual waste log data were collected. Active and control vials (prepared using sterilized trypticase soy broth) were recovered, instead of discarded, at the defined 6-hour BUD. The institution-specific waste of 19 selected SDV medications discarded at 6 hours was calculated at $766,000 annually, and tracking waste logs for these same medications was recorded at $770,000 annually. Microbiologic testing of vial extension beyond 6 hours showed that 11 (1.86%) of 592 samples had one colony-forming unit on one of two plates. Positive plates were negative at subsequent time points, and all positives were single isolates most likely introduced during the plating process. The cost of discarding vials at 6 hours was significant for hazardous medications in a large academic medical center. On the basis of microbiologic data, vial BUD extension demonstrated a contamination frequency of 1.86%, which likely represented exogenous contamination; vial BUD extension for the tested drugs showed no growth at subsequent time points and could provide an annual cost savings of more than $600,000.
Effect of low-level pulsed laser 890-nm on lumbar spondylolisthesis: a case report
NASA Astrophysics Data System (ADS)
Mortazavi, Seyed M. J.; Afsharpad, Mitra; Djavid, Gholam-reza E.
2002-10-01
Objective: Evaluating the effectiveness of low-level laser therapy (LLLT) in alleviating the symptoms of lumbar spondylolisthesis. Materials and Methods: Laser was irradiated for 2 mm at six symmetric points along the lumbosacral spine and 5 points along the referred point ofpain, six times a week for 2 weeks (890 nm; 8 J/cm2; pulsed at 1500 Hz). Perception of benefit, level of function was assessed by the Oswestry disability index, lumbar mobility range of motion and low back pain intensity. Results and Discussion: Results showed a complete reduction in pain and improvement in function in the patient. This case report suggests that low-level laser therapy (LLLT) could play a role in conservative management of low-grade lumbar spondylolisthesis.
Small catchments DEM creation using Unmanned Aerial Vehicles
NASA Astrophysics Data System (ADS)
Gafurov, A. M.
2018-01-01
Digital elevation models (DEM) are an important source of information on the terrain, allowing researchers to evaluate various exogenous processes. The higher the accuracy of DEM the better the level of the work possible. An important source of data for the construction of DEMs are point clouds obtained with terrestrial laser scanning (TLS) and unmanned aerial vehicles (UAV). In this paper, we present the results of constructing a DEM on small catchments using UAVs. Estimation of the UAV DEM showed comparable accuracy with the TLS if real time kinematic Global Positioning System (RTK-GPS) ground control points (GCPs) and check points (CPs) were used. In this case, the main source of errors in the construction of DEMs are the errors in the referencing of survey results.
Development of Pointing Device Using DC-Coupled Electrooculogram
NASA Astrophysics Data System (ADS)
Uchitomi, Hirotaka; Hori, Junichi
A purpose of this study is to support communication of developmentally disabled individuals with motor paralysis, such as Guillain-Barre Syndrome, brain-stem infarction, having difficulty in conveying their intention. In the present paper, a pointing device controlled by DC-coupled electrooculograms (EOGs) has been developed. The optic angle of the subject was estimated from the amplitude of vertical and horizontal EOGs for determining the two dimensional pointing position on the PC screen in real time. The eye blinking artifact was reduced using a median filter. The displacement of electrode position was compensated by considering the potential gradient. Moreover, the position error caused by drift phenomenon was adjusted by using head movement. The accuracy and operating speed of the proposed method were evaluated in human experiments.
Hoppin, Jane A; Ulmer, Ross; Calafat, Antonia M; Barr, Dana B; Baker, Susan V; Meltzer, Helle M; Rønningen, Kjersti S
2006-01-01
Collection of urine samples in human studies involves choices regarding shipping, sample preservation, and storage that may ultimately influence future analysis. As more studies collect and archive urine samples to evaluate environmental exposures in the future, we were interested in assessing the impact of urine preservative, storage temperature, and time since collection on nonpersistent contaminants in urine samples. In spiked urine samples stored in three types of urine vacutainers (no preservative, boric acid, and chlorhexidine), we measured five groups of contaminants to assess the levels of these analytes at five time points (0, 24, 48, and 72 h, and 1 week) and at two temperatures (room temperature and 4 degrees C). The target chemicals were bisphenol A (BPA), metabolites of organophosphate (OP), carbamate, and pyrethroid insecticides, chlorinated phenols, and phthalate monoesters, and were measured using five different mass spectrometry-based methods. Three samples were analyzed at each time point, with the exception of BPA. Repeated measures analysis of variance was used to evaluate effects of storage time, temperature, and preservative. Stability was summarized with percent change in mean concentration from time 0. In general, most analytes were stable under all conditions with changes in mean concentration over time, temperature, and preservative being generally less than 20%, with the exception of the OP metabolites in the presence of boric acid. The effect of storage temperature was less important than time since collection. The precision of the laboratory measurements was high allowing us to observe small differences, which may not be important when categorizing individuals into broader exposure groups.
Modeling an enhanced ridesharing system with meet points and time windows
Li, Xin; Hu, Sangen; Deng, Kai
2018-01-01
With the rising of e-hailing services in urban areas, ride sharing is becoming a common mode of transportation. This paper presents a mathematical model to design an enhanced ridesharing system with meet points and users’ preferable time windows. The introduction of meet points allows ridesharing operators to trade off the benefits of saving en-route delays and the cost of additional walking for some passengers to be collectively picked up or dropped off. This extension to the traditional door-to-door ridesharing problem brings more operation flexibility in urban areas (where potential requests may be densely distributed in neighborhood), and thus could achieve better system performance in terms of reducing the total travel time and increasing the served passengers. We design and implement a Tabu-based meta-heuristic algorithm to solve the proposed mixed integer linear program (MILP). To evaluate the validation and effectiveness of the proposed model and solution algorithm, several scenarios are designed and also resolved to optimality by CPLEX. Results demonstrate that (i) detailed route plan associated with passenger assignment to meet points can be obtained with en-route delay savings; (ii) as compared to CPLEX, the meta-heuristic algorithm bears the advantage of higher computation efficiency and produces good quality solutions with 8%~15% difference from the global optima; and (iii) introducing meet points to ridesharing system saves the total travel time by 2.7%-3.8% for small-scale ridesharing systems. More benefits are expected for ridesharing systems with large size of fleet. This study provides a new tool to efficiently operate the ridesharing system, particularly when the ride sharing vehicles are in short supply during peak hours. Traffic congestion mitigation will also be expected. PMID:29715302
Evaluation of TRMM Ground-Validation Radar-Rain Errors Using Rain Gauge Measurements
NASA Technical Reports Server (NTRS)
Wang, Jianxin; Wolff, David B.
2009-01-01
Ground-validation (GV) radar-rain products are often utilized for validation of the Tropical Rainfall Measuring Mission (TRMM) spaced-based rain estimates, and hence, quantitative evaluation of the GV radar-rain product error characteristics is vital. This study uses quality-controlled gauge data to compare with TRMM GV radar rain rates in an effort to provide such error characteristics. The results show that significant differences of concurrent radar-gauge rain rates exist at various time scales ranging from 5 min to 1 day, despite lower overall long-term bias. However, the differences between the radar area-averaged rain rates and gauge point rain rates cannot be explained as due to radar error only. The error variance separation method is adapted to partition the variance of radar-gauge differences into the gauge area-point error variance and radar rain estimation error variance. The results provide relatively reliable quantitative uncertainty evaluation of TRMM GV radar rain estimates at various times scales, and are helpful to better understand the differences between measured radar and gauge rain rates. It is envisaged that this study will contribute to better utilization of GV radar rain products to validate versatile spaced-based rain estimates from TRMM, as well as the proposed Global Precipitation Measurement, and other satellites.
Development of a preprototype times wastewater recovery subsystem, addendum
NASA Technical Reports Server (NTRS)
Dehner, G. F.
1984-01-01
Six tasks are described reflecting subsystem hardware and software modifications and test evaluation of a TIMES wastewater recovery subsystem. The overall results are illustrated in a figure which shows the water production rate, the specific energy corrected to 26.5 VDC, and the product water conductivity at various points in the testing. Four tasks are described reflecting studies performed to develop a preliminary design concept for a next generation TIMES. The overall results of the study are the completion of major design analyses and preliminary configuration layout drawings.
NASA Technical Reports Server (NTRS)
Rosenstein, H.; Mcveigh, M. A.; Mollenkof, P. A.
1973-01-01
A mathematical model for a real time simulation of a tilt rotor aircraft was developed. The mathematical model is used for evaluating aircraft performance and handling qualities. The model is based on an eleven degree of freedom total force representation. The rotor is treated as a point source of forces and moments with appropriate response time lags and actuator dynamics. The aerodynamics of the wing, tail, rotors, landing gear, and fuselage are included.
Infant feeding attitudes of women in the United Kingdom during pregnancy and after birth.
Wilkins, Carol; Ryan, Kath; Green, Josephine; Thomas, Peter
2012-11-01
To address the recognized low rates of breastfeeding in the United Kingdom (UK), a change in fundamental attitudes toward infant feeding might be required. This paper reports an exploration of women's attitudes toward breastfeeding at different time points in the perinatal period, undertaken as part of a larger breastfeeding evaluation study. To measure women's infant feeding attitudes at 3 stages during the perinatal period to see whether, on average, they differed over time. Using the 17-item Iowa Infant Feeding Attitudes Scale (IIFAS), this cross-sectional study measured the infant feeding attitudes of 866 UK women at 3 perinatal stages (20 and 35 weeks antenatally and 6 weeks postpartum). Mean IIFAS scores were very similar, which shows that discrete groups of women at different time points in pregnancy and postpartum appear to have the same attitudes toward infant feeding. The predominance of scores lay in the mid-range at each of the time points, which may indicate women's indecision or ambivalent feelings about infant feeding during pregnancy and the postpartum period. Action must be undertaken to target the majority of women with mid-range scores whose ambivalence may respond positively to intervention programs. The challenge is to understand what would be appropriate and acceptable to this vulnerable group of women.
Keijzer, Henry; Smits, Marcel G; Peeters, Twan; Looman, Caspar W N; Endenburg, Silvia C; Gunnewiek, Jacqueline M T Klein
2011-08-17
Dim Light Melatonin Onset (DLMO) can be calculated within a 5-point partial melatonin curve in saliva collected at home. We retrospectively analyzed the patient melatonin measurements sample size of the year 2008 to evaluate these DLMO calculations and studied the correlation between diary or polysomnography (PSG) sleep onset and DLMO. Patients completed an online questionnaire. If this questionnaire pointed to a possible Delayed Sleep Phase Disorder (DSPD), saliva collection devices were sent to the patient. Collection occurred at 5 consecutive hours. Melatonin concentration was measured with a radioimmunoassay and DLMO was defined as the time at which the melatonin concentration in saliva reaches 4 pg/mL. Sleep onset time was retrieved from an online one-week sleep diary and/or one-night PSG. A total of 1848 diagnostic 5-point curves were obtained. DLMO could be determined in 76.2% (n=1408). DLMO significantly differed between different age groups and increased with age. Pearson correlations (r) between DLMO and sleep onset measured with PSG or with a diary were 0.514 (p=<0.001, n=54) and 0.653 (p=0.002, n=20) respectively. DLMO can be reliably measured in saliva that is conveniently collected at home. DLMO correlates moderately with sleep onset. Copyright © 2011 Elsevier B.V. All rights reserved.
Fretheim, Atle; Zhang, Fang; Ross-Degnan, Dennis; Oxman, Andrew D; Cheyne, Helen; Foy, Robbie; Goodacre, Steve; Herrin, Jeph; Kerse, Ngaire; McKinlay, R James; Wright, Adam; Soumerai, Stephen B
2015-03-01
There is often substantial uncertainty about the impacts of health system and policy interventions. Despite that, randomized controlled trials (RCTs) are uncommon in this field, partly because experiments can be difficult to carry out. An alternative method for impact evaluation is the interrupted time-series (ITS) design. Little is known, however, about how results from the two methods compare. Our aim was to explore whether ITS studies yield results that differ from those of randomized trials. We conducted single-arm ITS analyses (segmented regression) based on data from the intervention arm of cluster randomized trials (C-RCTs), that is, discarding control arm data. Secondarily, we included the control group data in the analyses, by subtracting control group data points from intervention group data points, thereby constructing a time series representing the difference between the intervention and control groups. We compared the results from the single-arm and controlled ITS analyses with results based on conventional aggregated analyses of trial data. The findings were largely concordant, yielding effect estimates with overlapping 95% confidence intervals (CI) across different analytical methods. However, our analyses revealed the importance of a concurrent control group and of taking baseline and follow-up trends into account in the analysis of C-RCTs. The ITS design is valuable for evaluation of health systems interventions, both when RCTs are not feasible and in the analysis and interpretation of data from C-RCTs. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Automated time activity classification based on global positioning system (GPS) tracking data
2011-01-01
Background Air pollution epidemiological studies are increasingly using global positioning system (GPS) to collect time-location data because they offer continuous tracking, high temporal resolution, and minimum reporting burden for participants. However, substantial uncertainties in the processing and classifying of raw GPS data create challenges for reliably characterizing time activity patterns. We developed and evaluated models to classify people's major time activity patterns from continuous GPS tracking data. Methods We developed and evaluated two automated models to classify major time activity patterns (i.e., indoor, outdoor static, outdoor walking, and in-vehicle travel) based on GPS time activity data collected under free living conditions for 47 participants (N = 131 person-days) from the Harbor Communities Time Location Study (HCTLS) in 2008 and supplemental GPS data collected from three UC-Irvine research staff (N = 21 person-days) in 2010. Time activity patterns used for model development were manually classified by research staff using information from participant GPS recordings, activity logs, and follow-up interviews. We evaluated two models: (a) a rule-based model that developed user-defined rules based on time, speed, and spatial location, and (b) a random forest decision tree model. Results Indoor, outdoor static, outdoor walking and in-vehicle travel activities accounted for 82.7%, 6.1%, 3.2% and 7.2% of manually-classified time activities in the HCTLS dataset, respectively. The rule-based model classified indoor and in-vehicle travel periods reasonably well (Indoor: sensitivity > 91%, specificity > 80%, and precision > 96%; in-vehicle travel: sensitivity > 71%, specificity > 99%, and precision > 88%), but the performance was moderate for outdoor static and outdoor walking predictions. No striking differences in performance were observed between the rule-based and the random forest models. The random forest model was fast and easy to execute, but was likely less robust than the rule-based model under the condition of biased or poor quality training data. Conclusions Our models can successfully identify indoor and in-vehicle travel points from the raw GPS data, but challenges remain in developing models to distinguish outdoor static points and walking. Accurate training data are essential in developing reliable models in classifying time-activity patterns. PMID:22082316
Automated time activity classification based on global positioning system (GPS) tracking data.
Wu, Jun; Jiang, Chengsheng; Houston, Douglas; Baker, Dean; Delfino, Ralph
2011-11-14
Air pollution epidemiological studies are increasingly using global positioning system (GPS) to collect time-location data because they offer continuous tracking, high temporal resolution, and minimum reporting burden for participants. However, substantial uncertainties in the processing and classifying of raw GPS data create challenges for reliably characterizing time activity patterns. We developed and evaluated models to classify people's major time activity patterns from continuous GPS tracking data. We developed and evaluated two automated models to classify major time activity patterns (i.e., indoor, outdoor static, outdoor walking, and in-vehicle travel) based on GPS time activity data collected under free living conditions for 47 participants (N = 131 person-days) from the Harbor Communities Time Location Study (HCTLS) in 2008 and supplemental GPS data collected from three UC-Irvine research staff (N = 21 person-days) in 2010. Time activity patterns used for model development were manually classified by research staff using information from participant GPS recordings, activity logs, and follow-up interviews. We evaluated two models: (a) a rule-based model that developed user-defined rules based on time, speed, and spatial location, and (b) a random forest decision tree model. Indoor, outdoor static, outdoor walking and in-vehicle travel activities accounted for 82.7%, 6.1%, 3.2% and 7.2% of manually-classified time activities in the HCTLS dataset, respectively. The rule-based model classified indoor and in-vehicle travel periods reasonably well (Indoor: sensitivity > 91%, specificity > 80%, and precision > 96%; in-vehicle travel: sensitivity > 71%, specificity > 99%, and precision > 88%), but the performance was moderate for outdoor static and outdoor walking predictions. No striking differences in performance were observed between the rule-based and the random forest models. The random forest model was fast and easy to execute, but was likely less robust than the rule-based model under the condition of biased or poor quality training data. Our models can successfully identify indoor and in-vehicle travel points from the raw GPS data, but challenges remain in developing models to distinguish outdoor static points and walking. Accurate training data are essential in developing reliable models in classifying time-activity patterns.
Laskowitz, Daniel T; Kasner, Scott E; Saver, Jeffrey; Remmel, Kerri S; Jauch, Edward C
2009-01-01
One of the significant limitations in the evaluation and management of patients with suspected acute cerebral ischemia is the absence of a widely available, rapid, and sensitive diagnostic test. The objective of the current study was to assess whether a test using a panel of biomarkers might provide useful diagnostic information in the early evaluation of stroke by differentiating patients with cerebral ischemia from other causes of acute neurological deficit. A total of 1146 patients presenting with neurological symptoms consistent with possible stroke were prospectively enrolled at 17 different sites. Timed blood samples were assayed for matrix metalloproteinase 9, brain natriuretic factor, d-dimer, and protein S100beta. A separate cohort of 343 patients was independently enrolled to validate the multiple biomarker model approach. A diagnostic tool incorporating the values of matrix metalloproteinase 9, brain natriuretic factor, d-dimer, and S-100beta into a composite score was sensitive for acute cerebral ischemia. The multivariate model demonstrated modest discriminative capabilities with an area under the receiver operating characteristic curve of 0.76 for hemorrhagic stroke and 0.69 for all stroke (likelihood test P<0.001). When the threshold for the logistic model was set at the first quartile, this resulted in a sensitivity of 86% for detecting all stroke and a sensitivity of 94% for detecting hemorrhagic stroke. Moreover, results were reproducible in a separate cohort tested on a point-of-care platform. These results suggest that a biomarker panel may add valuable and time-sensitive diagnostic information in the early evaluation of stroke. Such an approach is feasible on a point-of-care platform. The rapid identification of patients with suspected stroke would expand the availability of time-limited treatment strategies. Although the diagnostic accuracy of the current panel is clearly imperfect, this study demonstrates the feasibility of incorporating a biomarker based point-of-care algorithm with readily available clinical data to aid in the early evaluation and management of patients at high risk for cerebral ischemia.
Garcia-Roig, Michael; Ridley, Derrick E; McCracken, Courtney; Arlen, Angela M; Cooper, Christopher S; Kirsch, Andrew J
2017-04-01
The Vesicoureteral Reflux Index is a validated tool that reliably predicts spontaneous resolution of reflux or at least 2 grades of improvement for patients diagnosed before age 24 months. We evaluated the Vesicoureteral Reflux Index in children older than 2 years. Patients younger than 18 years who were diagnosed with primary vesicoureteral reflux after age 24 months and had undergone 2 or more voiding cystourethrograms were identified. Disease severity was scored using the Vesicoureteral Reflux Index, a 6-point scale based on gender, reflux grade, ureteral abnormalities and reflux timing. Proportional subdistribution hazard models for competing risks identified variables associated with resolution/improvement at different time points. A total of 21 males and 250 females met inclusion criteria. Mean ± SD age was 4.0 ± 2.1 years and patients had a median vesicoureteral reflux grade of 2. The Vesicoureteral Reflux Index score improved by 1 point in 1 patient (100%), 2 points in 25 (67.6%), 3 points in 48 (37%), 4 points in 18 (21.4%) and 5 to 6 points in 4 (18.2%). Female gender (p = 0.005) and vesicoureteral reflux timing (late filling, p = 0.002; early/mid filling, p <0.001) independently predicted nonresolution. Median resolution time based on Vesicoureteral Reflux Index score was 2 months or less in 15.6% of patients (95% CI 11.0-13.8), 3 months in 34.7% (95% CI 25.4-44.1), 4 months in 55.9% (95% CI 40.1 to infinity) and 5 months or more in 30.3% (95% CI 29.5 to infinity). High grade (IV or V) reflux was not associated with resolution at any point. Ureteral abnormalities were associated with lack of resolution in the first 12 to 18 months (HR 0.29, 95% CI 0.29-0.80) but not in later followup. Vesicoureteral Reflux Index scores of 3, 4 and 5 were significantly associated with lack of resolution/improvement compared to scores of 2 or less (p = 0.031). The Vesicoureteral Reflux Index reliably predicts primary vesicoureteral reflux improvement/resolution in children diagnosed after age 24 months. Spontaneous resolution/improvement is less likely as Vesicoureteral Reflux Index score and time from diagnosis increase. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Lacerda, Thaisa Cardoso; von Wangenheim, Christiane Gresse; von Wangenheim, Aldo; Giuliano, Isabela
2014-12-01
One of the main reasons that leads to a low adoption rate of telemedicine systems is poor usability. An aspect that influences usability during the reporting of findings is the input mode, e.g., if a free-text (FT) or a structured report (SR) interface is employed. The objective of our study is to compare the usability of FT and ST telemedicine systems, specifically in terms of user satisfaction, efficiency and general usability. We comparatively evaluate the usability of these two input modes in a telecardiology system for issuing electrocardiography reports in the context of a statewide telemedicine system in Brazil with more than 350.000 performed tele-electrocardiography examinations. We adopted a multiple method research strategy, applying three different kinds of usability evaluations: user satisfaction was evaluated through interviews with seven medical professionals using the System Usability Scale (SUS) questionnaire and specific questions related to adequacy and user experience. Efficiency was evaluated by estimating execution time using the Keystroke-Level Model (KLM). General usability was assessed based on the conformity of the systems to a set of e-health specific usability heuristics. The results of this comparison provide a first indication that a structured report (SR) input mode for such a system is more satisfactory and efficient with a larger conformity to usability heuristics than free-text (FT) input. User satisfaction using the SUS questionnaire has been scored in average with 58.8 and 77.5 points for the FT and SR system, respectively, which means that the SR system was rated 18.65 points higher than the FT system. In terms of efficiency, the completion of a findings report using the SR mode is estimated to take 8.5s, 3.74 times faster than using the FT system (31.8s). The SR system also demonstrated less violations to usability heuristics (8 points) in comparison to 14 points observed in the FT system. These results provide a first indication that the usage of structured reporting as an input mode in telecardiology systems may enhance usability. This also seems to confirm the advantages of the usage of structured reporting, as already described in the literature for other areas such as teleradiology. Copyright © 2014 Elsevier Inc. All rights reserved.
The Expert Infantryman Squad and Platoon Evaluation (EISPE) I Concept: Evaluations and Observations
1977-12-01
specific perforanc•a test imetditelv following the roa’ &.:-rch requires the Infantryman to show he r n still function AccA .-’a\\;ifter the stress of...weighed against thn cost of devoting an hour or two of valuable testing time to this activity. Similarly, it is debatable whether tre coordinated...the objective effective? (9) Was withdrawal free the objective rapid and organized? (10) Was everyone accounted for at the oojective raily point? (11
Sastre, Salvador; Fernández Torija, Carlos; Carbonell, Gregoria; Rodríguez Martín, José Antonio; Beltrán, Eulalia María; González-Doncel, Miguel
2018-02-01
A diet fortified with 2,2', 4,4'-tetrabromodiphenyl ether (BDE-47: 0, 10, 100, and 1000 ng/g) was dosed to 4-7-day-old post-hatch medaka fish for 40 days to evaluate the effects on the swimming activity of fish using a miniaturized swimming flume. Chlorpyrifos (CF)-exposed fish were selected as the positive control to assess the validity and sensitivity of the behavioral findings. After 20 and 40 days of exposure, the locomotor activity was analyzed for 6 min in a flume section (arena). The CF positive control for each time point were fish exposed to 50 ng CF/ml for 48 h. Swimming patterns, presented as two-dimensional heat maps of fish movement and positioning, were obtained by geostatistical analyses. The heat maps of the control groups at time point 20 revealed visually comparable swimming patterns to those of the BDE-47-treated groups. For the comparative fish positioning analysis, both the arenas were divided into 15 proportional areas. No statistical differences were found between residence times in the areas from the control groups and those from the BDE-47-treated groups. At time point 40, the heat map overall patterns of the control groups differed visually from that of the 100-ng BDE-47/g-treated group, but a comparative analysis of the residence times in the corresponding 15 areas did not reveal consistent differences. The relative distances traveled by the control and treated groups at time points 20 and 40 were also comparable. The heat maps of CF-treated fish at both time points showed contrasting swim patterns with respect to those of the controls. These differential patterns were statistically supported with differences in the residence times for different areas. The relative distances traveled by the CF-treated fish were also significantly shorter. These results confirm the validity of the experimental design and indicate that a dietary BDE-47 exposure does not affect forced swimming in medaka at growing stages. Copyright © 2017 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Kadhi, T.; Holley, D.; Palasota, A.
2010-01-01
The following report gives descriptive and correlational statistical findings of the Grade Point Averages (GPAs) of the February 2010 and July 2009 TMSL First Time Texas Bar Test Takers to their TMSL Final GPA. Data was pre-existing and was given to the Evaluator by email from the Dean and Registrar. Statistical analyses were run using SPSS 17 to…
2003-10-01
Hansen, A.D.A., H. Rosen, T. Novakov (1984). The Aethalometer - An Instrument for the Real-Time Measurement of Optical Absorption by Aerosol Particles...hydrological cycles (Ramanathan and Crutzen 2003). Historical trends point towards increasing levels of BC production ( Novakov , Ramanathan et al. 2003...immunology : official organ of American Academy of Allergy 102(4 1): 539-554. Novakov , T., V. Ramanathan, J. E. Hansen, T. W. Kirchstetter, M. Sato, J. E
Schuck, Sabrina; Emmerson, Natasha; Ziv, Hadar; Collins, Penelope; Arastoo, Sara; Warschauer, Mark; Crinella, Francis; Lakes, Kimberley
2016-01-01
Children with Attention Deficit/Hyperactivity Disorder (ADHD) receive approximately 80% of instruction in the general education classroom, where individualized behavioral management strategies may be difficult for teachers to consistently deliver. Mobile device apps provide promising platforms to manage behavior. This pilot study evaluated the utility of a web-based application (iSelfControl) designed to support classroom behavior management. iSelfControl prompted students every 'Center' (30-minutes) to self-evaluate using a universal token-economy classroom management system focused on compliance, productivity, and positive relationships. Simultaneously, the teacher evaluated each student on a separate iPad. Using Multi Level Modeling, we examined 13 days of data gathered from implementation with 5th grade students (N = 12) at a school for children with ADHD and related executive function difficulties. First, an unconditional growth model evaluated the overall amount of change in aggregated scores over time as well as the degree of systematic variation in scores within and across teacher-student dyads. Second, separate intercepts and slopes were estimated for teacher and student to estimate degree of congruency between trajectories. Finally, differences between teacher and student scores were tested at each time-point in separate models to examine unique 'Center' effects. 51% of the total variance in scores was attributed to differences between dyads. Trajectories of student and teacher scores remained relatively stable across seven time-points each day and did not statistically differ from each other. On any given day, students tended to evaluate their behaviors more positively (entered higher scores for themselves) compared to corresponding teacher scores. In summary, iSelfControl provides a platform for self and teacher evaluation that is an important adjunct to conventional classroom management strategies. The application captured teacher/student discrepancies and significant variations across the day. Future research with a larger, clinically diagnosed sample in multiple classrooms is needed to assess generalizability to a wider variety of classroom settings.
Evaluation of GPS Coverage for the X-33 Michael-6 Trajectory
NASA Technical Reports Server (NTRS)
Lundberg, John B.
1998-01-01
The onboard navigational system for the X-33 test flights will be based on the use of measurements collected from the Embedded Global Positioning System (GPS)/INS system. Some of the factors which will affect the quality of the GPS contribution to the navigational solution will be the number of pseudorange measurements collected at any instant in time, the distribution of the GPS satellites within the field of view, and the inherent noise level of the GPS receiver. The distribution of GPS satellites within the field of view of the receiver's antenna will depend on the receiver's position, the time of day, pointing direction of the antenna, and the effective cone angle of the antenna. The number of pseudorange measurements collected will depend upon these factors as well as the time required to lock onto a GPS satellite signal once the GPS satellite comes into the field of view of the antenna and the number of available receiver channels. The objective of this study is to evaluate the GPS coverage resulting from the proposed antenna pointing directions, the proposed antenna cone angles, and the effects due to the time of day for the X-33 Michael-6 trajectory from launch at Edwards AFB, California, to the start of the Terminal Area Energy Management (TAEM) phase on approach to Michael AAF, Utah.
Jia, Lang; Chen, Jinyun; Wang, Yan; Liu, Yingjiang; Zhang, Yu; Chen, Wenzhi
2014-01-01
This study aimed to assess changes in osteophytic, chondral, and subchondral structures in a surgically-induced osteoarthritis (OA) rabbit model in order to correlate MRI findings with the macroscopic progress of OA and to define the timepoint for disease status in this OA model. The OA model was constructed by surgery in thirty rabbits with ten normal rabbits serving as controls (baseline). High-resolution three-dimensional MRI using a 1.5-T coil was performed at baseline, two, four, and eight weeks post-surgery. MRIs of cartilage lesions, subchondral bone lesions, and osteophyte formations were independently assessed by two blinded radiologists. Ten rabbits were sacrificed at baseline, two, four, and eight weeks post-surgery, and macroscopic evaluation was independently performed by two blinded orthopedic surgeons. The signal intensities and morphologies of chondral and subchondral structures by MRI accurately reflected the degree of OA. Cartilage defects progressed from a grade of 0.05-0.15 to 1.15-1.30 to 1.90-1.97 to 3.00-3.35 at each successive time point, respectively (p<0.05). Subchondral bone lesions progressed from a grade of 0.00 to 0.78-0.90 to 1.27-1.58 to 1.95-2.23 at each successive time point, respectively (p = 0.000). Osteophytes progressed from a size (mm) of 0.00 to 0.87-1.06 to 1.24-1.87 to 2.21-3.21 at each successive time point, respectively (p = 0.000). Serial observations revealed that MRI can accurately detect the progression of cartilage lesions and subchondral bone edema over an eight-week period but may not be accurate in detecting osteophyte sizes. Week four post-surgery was considered the timepoint between OA-negative and OA-positive status in this OA model. The combination of this OA model with MRI evaluation should provide a promising tool for the pre-clinical evaluation of new disease-modifying osteoarthritis drugs.
Comparison of Chang Run Tong and Forlaxin Treatment of Constipation in Elderly Diabetic Patients.
Zhao, Dong; Zhao, Jing-Bo
2018-05-01
Constipation is quite common and has impact on life quality in the elderly diabetic patients; therefore it is important to seek better treatments. The aim of this study is to evaluate the effect of Chang Run Tong (CRT) decoction on constipation in elderly diabetic patients in comparison with the effect of Macrogol 4000 powder (Forlax). This study was designed as a prospective study consisting of two parallel arms: CRT group and Forlax group. The study was conducted in China-Japan Hospital. Subject interventions: Eighty elderly diabetic patients with constipation were evaluated, among them 52 patients were treated with CRT and 28 patients were treated with Forlax. The patients were interviewed for Bristol stool scale, spontaneous complete bowel movements (SCBM) and symptoms of defecation feeling, defecation weakness, feeling of incomplete evacuation, bloating, and flatulence at different time points. The changes of all above parameters from treatment for 2 and 4 weeks and follow-up for 1 and 2 months with reference to the baseline (before treatment) were compared between CRT and Forlax treatments. The treatment efficiency was evaluated and compared between two different treatments. For the improvement of Bristol stool scale, SCBM and feeling of incomplete evacuation, CRT was significantly better than Forlax at different time points (p < 0.01, p < 0.001). For the symptoms of defecation feeling, defecation weakness, bloating, and flatulence, CRT was significantly better than Forlax for follow-up improvement (p < 0.01, p < 0.001); whereas no difference was found at other time points of the treatment (p > 0.05). Furthermore, CRT had a significantly better treatment efficiency than Forlax (p < 0.001). Both CRT and Forlax treatment could effectively improve bowel habits and symptoms of constipation in elderly diabetic patients. CRT was better than Forlax to treat constipation in elderly diabetic patients and had better follow-up improvement after stopping drugs.
Effect of Low-Level Laser Therapy and Strength Training Protocol on Hand Grip by Dynamometry
Barbosa, Rafael; Marcolino, Alexandre; Souza, Vitor; Bertolino, Guilherme; Fonseca, Marisa; Guirro, Rinaldo
2017-01-01
Introduction: The purpose of this study was to investigate the effect of low-level laser therapy (LLLT) – 660 nm and 904 nm - before grip strength protocol in healthy subjects. Methods: The study included 45 healthy volunteers with an average age of 22.7 (±1.4) years, subdivided into the following groups, control group: grip strength training associated with placebo LLLT; 660 nm group: LLLT (660 nm, 20 J/cm2, power of 30 mW, and beam area of 0.06 cm2, continuous, energy 1.2 J, and exposure time 40 seconds per point) before grip strength training and 904 nm group: LLLT (904 nm, 10 J/cm2, peak power of 70 W and 0.13 cm2 beam area, with pulsed beam 9.500 Hz and 30 seconds of exposure time per point and emitted energy 1.2 J) before grip strength training. The LLLT was timed to contact 10 points located in the region of the superficial and deep flexor muscles of the fingers, with a total energy of 12.0 J per session. For the strength training protocol, the volunteer exercised their fingers with the dominant hand on a small table, elbow flexed at 90°, forearm in neutral, using a light extension handle. The Oxford protocol was performed during four weeks. The grip strength was assessed using a dynamometer (Jamar™). The data were evaluated by the analysis of variance (ANOVA) statistical method. Results: In the comparison of intragroup evaluation, only the 904 nm group showed a difference compared to the baseline assessment after 4 weeks (P < 0.05), in the final intergroup evaluation, a difference was observed in the comparison between the control and 904 nm groups Conclusion: In conclusion, LLLT (904 nm) applied before resistance training was effective in gaining grip strength when compared to LLLT (660 nm) and isolated strength training after 4 weeks. PMID:29123629
Theoretical relation between halo current-plasma energy displacement/deformation in EAST
NASA Astrophysics Data System (ADS)
Khan, Shahab Ud-Din; Khan, Salah Ud-Din; Song, Yuntao; Dalong, Chen
2018-04-01
In this paper, theoretical model for calculating halo current has been developed. This work attained novelty as no theoretical calculations for halo current has been reported so far. This is the first time to use theoretical approach. The research started by calculating points for plasma energy in terms of poloidal and toroidal magnetic field orientations. While calculating these points, it was extended to calculate halo current and to developed theoretical model. Two cases were considered for analyzing the plasma energy when flows down/upward to the diverter. Poloidal as well as toroidal movement of plasma energy was investigated and mathematical formulations were designed as well. Two conducting points with respect to (R, Z) were calculated for halo current calculations and derivations. However, at first, halo current was established on the outer plate in clockwise direction. The maximum generation of halo current was estimated to be about 0.4 times of the plasma current. A Matlab program has been developed to calculate halo current and plasma energy calculation points. The main objective of the research was to establish theoretical relation with experimental results so as to precautionary evaluate the plasma behavior in any Tokamak.
An improved DPSM technique for modelling ultrasonic fields in cracked solids
NASA Astrophysics Data System (ADS)
Banerjee, Sourav; Kundu, Tribikram; Placko, Dominique
2007-04-01
In recent years Distributed Point Source Method (DPSM) is being used for modelling various ultrasonic, electrostatic and electromagnetic field modelling problems. In conventional DPSM several point sources are placed near the transducer face, interface and anomaly boundaries. The ultrasonic or the electromagnetic field at any point is computed by superimposing the contributions of different layers of point sources strategically placed. The conventional DPSM modelling technique is modified in this paper so that the contributions of the point sources in the shadow region can be removed from the calculations. For this purpose the conventional point sources that radiate in all directions are replaced by Controlled Space Radiation (CSR) sources. CSR sources can take care of the shadow region problem to some extent. Complete removal of the shadow region problem can be achieved by introducing artificial interfaces. Numerically synthesized fields obtained by the conventional DPSM technique that does not give any special consideration to the point sources in the shadow region and the proposed modified technique that nullifies the contributions of the point sources in the shadow region are compared. One application of this research can be found in the improved modelling of the real time ultrasonic non-destructive evaluation experiments.
Identification of the ideal clutter metric to predict time dependence of human visual search
NASA Astrophysics Data System (ADS)
Cartier, Joan F.; Hsu, David H.
1995-05-01
The Army Night Vision and Electronic Sensors Directorate (NVESD) has recently performed a human perception experiment in which eye tracker measurements were made on trained military observers searching for targets in infrared images. This data offered an important opportunity to evaluate a new technique for search modeling. Following the approach taken by Jeff Nicoll, this model treats search as a random walk in which the observers are in one of two states until they quit: they are either searching, or they are wandering around looking for a point of interest. When wandering they skip rapidly from point to point. When examining they move more slowly, reflecting the fact that target discrimination requires additional thought processes. In this paper we simulate the random walk, using a clutter metric to assign relative attractiveness to points of interest within the image which are competing for the observer's attention. The NVESD data indicates that a number of standard clutter metrics are good estimators of the apportionment of observer's time between wandering and examining. Conversely, the apportionment of observer time spent wandering and examining could be used to reverse engineer the ideal clutter metric which would most perfectly describe the behavior of the group of observers. It may be possible to use this technique to design the optimal clutter metric to predict performance of visual search.
[The added value of information summaries supporting clinical decisions at the point-of-care.
Banzi, Rita; González-Lorenzo, Marien; Kwag, Koren Hyogene; Bonovas, Stefanos; Moja, Lorenzo
2016-11-01
Evidence-based healthcare requires the integration of the best research evidence with clinical expertise and patients' values. International publishers are developing evidence-based information services and resources designed to overcome the difficulties in retrieving, assessing and updating medical information as well as to facilitate a rapid access to valid clinical knowledge. Point-of-care information summaries are defined as web-based medical compendia that are specifically designed to deliver pre-digested, rapidly accessible, comprehensive, and periodically updated information to health care providers. Their validity must be assessed against marketing claims that they are evidence-based. We periodically evaluate the content development processes of several international point-of-care information summaries. The number of these products has increased along with their quality. The last analysis done in 2014 identified 26 products and found that three of them (Best Practice, Dynamed e Uptodate) scored the highest across all evaluated dimensions (volume, quality of the editorial process and evidence-based methodology). Point-of-care information summaries as stand-alone products or integrated with other systems, are gaining ground to support clinical decisions. The choice of one product over another depends both on the properties of the service and the preference of users. However, even the most innovative information system must rely on transparent and valid contents. Individuals and institutions should regularly assess the value of point-of-care summaries as their quality changes rapidly over time.
Interactive-cut: Real-time feedback segmentation for translational research.
Egger, Jan; Lüddemann, Tobias; Schwarzenberg, Robert; Freisleben, Bernd; Nimsky, Christopher
2014-06-01
In this contribution, a scale-invariant image segmentation algorithm is introduced that "wraps" the algorithm's parameters for the user by its interactive behavior, avoiding the definition of "arbitrary" numbers that the user cannot really understand. Therefore, we designed a specific graph-based segmentation method that only requires a single seed-point inside the target-structure from the user and is thus particularly suitable for immediate processing and interactive, real-time adjustments by the user. In addition, color or gray value information that is needed for the approach can be automatically extracted around the user-defined seed point. Furthermore, the graph is constructed in such a way, so that a polynomial-time mincut computation can provide the segmentation result within a second on an up-to-date computer. The algorithm presented here has been evaluated with fixed seed points on 2D and 3D medical image data, such as brain tumors, cerebral aneurysms and vertebral bodies. Direct comparison of the obtained automatic segmentation results with costlier, manual slice-by-slice segmentations performed by trained physicians, suggest a strong medical relevance of this interactive approach. Copyright © 2014 Elsevier Ltd. All rights reserved.
Dynamic connectivity regression: Determining state-related changes in brain connectivity
Cribben, Ivor; Haraldsdottir, Ragnheidur; Atlas, Lauren Y.; Wager, Tor D.; Lindquist, Martin A.
2014-01-01
Most statistical analyses of fMRI data assume that the nature, timing and duration of the psychological processes being studied are known. However, often it is hard to specify this information a priori. In this work we introduce a data-driven technique for partitioning the experimental time course into distinct temporal intervals with different multivariate functional connectivity patterns between a set of regions of interest (ROIs). The technique, called Dynamic Connectivity Regression (DCR), detects temporal change points in functional connectivity and estimates a graph, or set of relationships between ROIs, for data in the temporal partition that falls between pairs of change points. Hence, DCR allows for estimation of both the time of change in connectivity and the connectivity graph for each partition, without requiring prior knowledge of the nature of the experimental design. Permutation and bootstrapping methods are used to perform inference on the change points. The method is applied to various simulated data sets as well as to an fMRI data set from a study (N=26) of a state anxiety induction using a socially evaluative threat challenge. The results illustrate the method’s ability to observe how the networks between different brain regions changed with subjects’ emotional state. PMID:22484408
Esposito, Fabrizio; Formisano, Elia; Seifritz, Erich; Goebel, Rainer; Morrone, Renato; Tedeschi, Gioacchino; Di Salle, Francesco
2002-07-01
Independent component analysis (ICA) has been successfully employed to decompose functional MRI (fMRI) time-series into sets of activation maps and associated time-courses. Several ICA algorithms have been proposed in the neural network literature. Applied to fMRI, these algorithms might lead to different spatial or temporal readouts of brain activation. We compared the two ICA algorithms that have been used so far for spatial ICA (sICA) of fMRI time-series: the Infomax (Bell and Sejnowski [1995]: Neural Comput 7:1004-1034) and the Fixed-Point (Hyvärinen [1999]: Adv Neural Inf Proc Syst 10:273-279) algorithms. We evaluated the Infomax- and Fixed Point-based sICA decompositions of simulated motor, and real motor and visual activation fMRI time-series using an ensemble of measures. Log-likelihood (McKeown et al. [1998]: Hum Brain Mapp 6:160-188) was used as a measure of how significantly the estimated independent sources fit the statistical structure of the data; receiver operating characteristics (ROC) and linear correlation analyses were used to evaluate the algorithms' accuracy of estimating the spatial layout and the temporal dynamics of simulated and real activations; cluster sizing calculations and an estimation of a residual gaussian noise term within the components were used to examine the anatomic structure of ICA components and for the assessment of noise reduction capabilities. Whereas both algorithms produced highly accurate results, the Fixed-Point outperformed the Infomax in terms of spatial and temporal accuracy as long as inferential statistics were employed as benchmarks. Conversely, the Infomax sICA was superior in terms of global estimation of the ICA model and noise reduction capabilities. Because of its adaptive nature, the Infomax approach appears to be better suited to investigate activation phenomena that are not predictable or adequately modelled by inferential techniques. Copyright 2002 Wiley-Liss, Inc.
Micro-Computed Tomography Evaluation of Human Fat Grafts in Nude Mice
Chung, Michael T.; Hyun, Jeong S.; Lo, David D.; Montoro, Daniel T.; Hasegawa, Masakazu; Levi, Benjamin; Januszyk, Michael; Longaker, Michael T.
2013-01-01
Background Although autologous fat grafting has revolutionized the field of soft tissue reconstruction and augmentation, long-term maintenance of fat grafts is unpredictable. Recent studies have reported survival rates of fat grafts to vary anywhere between 10% and 80% over time. The present study evaluated the long-term viability of human fat grafts in a murine model using a novel imaging technique allowing for in vivo volumetric analysis. Methods Human fat grafts were prepared from lipoaspirate samples using the Coleman technique. Fat was injected subcutaneously into the scalp of 10 adult Crl:NU-Foxn1nu CD-1 male mice. Micro-computed tomography (CT) was performed immediately following injection and then weekly thereafter. Fat volume was rendered by reconstructing a three-dimensional (3D) surface through cubic-spline interpolation. Specimens were also harvested at various time points and sections were prepared and stained with hematoxylin and eosin (H&E), for macrophages using CD68 and for the cannabinoid receptor 1 (CB1). Finally, samples were explanted at 8- and 12-week time points to validate calculated micro-CT volumes. Results Weekly CT scanning demonstrated progressive volume loss over the time course. However, volumetric analysis at the 8- and 12-week time points stabilized, showing an average of 62.2% and 60.9% survival, respectively. Gross analysis showed the fat graft to be healthy and vascularized. H&E analysis and staining for CD68 showed minimal inflammatory reaction with viable adipocytes. Immunohistochemical staining with anti-human CB1 antibodies confirmed human origin of the adipocytes. Conclusions Studies assessing the fate of autologous fat grafts in animals have focused on nonimaging modalities, including histological and biochemical analyses, which require euthanasia of the animals. In this study, we have demonstrated the ability to employ micro-CT for 3D reconstruction and volumetric analysis of human fat grafts in a mouse model. Importantly, this model provides a platform for subsequent study of fat manipulation and soft tissue engineering. PMID:22916732
Measuring Incompatible Observables by Exploiting Sequential Weak Values.
Piacentini, F; Avella, A; Levi, M P; Gramegna, M; Brida, G; Degiovanni, I P; Cohen, E; Lussana, R; Villa, F; Tosi, A; Zappa, F; Genovese, M
2016-10-21
One of the most intriguing aspects of quantum mechanics is the impossibility of measuring at the same time observables corresponding to noncommuting operators, because of quantum uncertainty. This impossibility can be partially relaxed when considering joint or sequential weak value evaluation. Indeed, weak value measurements have been a real breakthrough in the quantum measurement framework that is of the utmost interest from both a fundamental and an applicative point of view. In this Letter, we show how we realized for the first time a sequential weak value evaluation of two incompatible observables using a genuine single-photon experiment. These (sometimes anomalous) sequential weak values revealed the single-operator weak values, as well as the local correlation between them.
Measuring Incompatible Observables by Exploiting Sequential Weak Values
NASA Astrophysics Data System (ADS)
Piacentini, F.; Avella, A.; Levi, M. P.; Gramegna, M.; Brida, G.; Degiovanni, I. P.; Cohen, E.; Lussana, R.; Villa, F.; Tosi, A.; Zappa, F.; Genovese, M.
2016-10-01
One of the most intriguing aspects of quantum mechanics is the impossibility of measuring at the same time observables corresponding to noncommuting operators, because of quantum uncertainty. This impossibility can be partially relaxed when considering joint or sequential weak value evaluation. Indeed, weak value measurements have been a real breakthrough in the quantum measurement framework that is of the utmost interest from both a fundamental and an applicative point of view. In this Letter, we show how we realized for the first time a sequential weak value evaluation of two incompatible observables using a genuine single-photon experiment. These (sometimes anomalous) sequential weak values revealed the single-operator weak values, as well as the local correlation between them.
NASA Astrophysics Data System (ADS)
Alidoost, F.; Arefi, H.
2017-11-01
Nowadays, Unmanned Aerial System (UAS)-based photogrammetry offers an affordable, fast and effective approach to real-time acquisition of high resolution geospatial information and automatic 3D modelling of objects for numerous applications such as topography mapping, 3D city modelling, orthophoto generation, and cultural heritages preservation. In this paper, the capability of four different state-of-the-art software packages as 3DSurvey, Agisoft Photoscan, Pix4Dmapper Pro and SURE is examined to generate high density point cloud as well as a Digital Surface Model (DSM) over a historical site. The main steps of this study are including: image acquisition, point cloud generation, and accuracy assessment. The overlapping images are first captured using a quadcopter and next are processed by different software to generate point clouds and DSMs. In order to evaluate the accuracy and quality of point clouds and DSMs, both visual and geometric assessments are carry out and the comparison results are reported.
NASA Astrophysics Data System (ADS)
Okumura, Hiroshi; Suezaki, Masashi; Sueyasu, Hideki; Arai, Kohei
2003-03-01
An automated method that can select corresponding point candidates is developed. This method has the following three features: 1) employment of the RIN-net for corresponding point candidate selection; 2) employment of multi resolution analysis with Haar wavelet transformation for improvement of selection accuracy and noise tolerance; 3) employment of context information about corresponding point candidates for screening of selected candidates. Here, the 'RIN-net' means the back-propagation trained feed-forward 3-layer artificial neural network that feeds rotation invariants as input data. In our system, pseudo Zernike moments are employed as the rotation invariants. The RIN-net has N x N pixels field of view (FOV). Some experiments are conducted to evaluate corresponding point candidate selection capability of the proposed method by using various kinds of remotely sensed images. The experimental results show the proposed method achieves fewer training patterns, less training time, and higher selection accuracy than conventional method.
Fire effects on the Point Reyes Mountain Beaver at Point Reyes National Seashore, California
Fellers, Gary M.; Pratt, David; Griffin, Jennifer L.
2004-01-01
In October 1995, a wildlands fire burned 5,000 ha on the Point Reyes peninsula, California, USA. In most of the nonforested areas, the fire effectively cleared the ground of litter and vegetation and revealed thousands of Point Reyes mountain beaver (Aplodontia rufa phaea) burrow openings. In the first 6 months after the fire, we surveyed burned coastal scrub and riparian habitat to (1) count the number of burrow openings that existed at the time of the fire, and (2) evaluate whether signs of post-fire mountain beaver activity were evident. We estimated that only 0.4–1.7% of mountain beavers within the burn area survived the fire and immediate post-fire period. We monitored mountain beaver activity for 5 years at 8 sites where mountain beavers survived, and found little or no recovery. We estimate that the mountain beaver population will take 15–20 years post-fire to recover.
Point-to-point connectivity prediction in porous media using percolation theory
NASA Astrophysics Data System (ADS)
Tavagh-Mohammadi, Behnam; Masihi, Mohsen; Ganjeh-Ghazvini, Mostafa
2016-10-01
The connectivity between two points in porous media is important for evaluating hydrocarbon recovery in underground reservoirs or toxic migration in waste disposal. For example, the connectivity between a producer and an injector in a hydrocarbon reservoir impact the fluid dispersion throughout the system. The conventional approach, flow simulation, is computationally very expensive and time consuming. Alternative method employs percolation theory. Classical percolation approach investigates the connectivity between two lines (representing the wells) in 2D cross sectional models whereas we look for the connectivity between two points (representing the wells) in 2D aerial models. In this study, site percolation is used to determine the fraction of permeable regions connected between two cells at various occupancy probabilities and system sizes. The master curves of mean connectivity and its uncertainty are then generated by finite size scaling. The results help to predict well-to-well connectivity without need to any further simulation.
Evaluating time dynamics of topographic threshold relations for gully initiation
NASA Astrophysics Data System (ADS)
Hayas, Antonio; Vanwalleghem, Tom; Poesen, Jean
2016-04-01
Gully erosion is one of the most important soil degradation processes at global scale. However, modelling of gully erosion is still difficult. Despite advances in the modelling of gully headcut rates and incision rates, it remains difficult to predict the location of gully initiation points and trajectories. In different studies it has been demonstrated that a good method of predicting gully initiation is by using a slope (S) - area (A) threshold. Such an S-A relation is a simple way of estimating the critical discharges needed to generate a critical shear stress that can incise a particular soil and initiate a gully. As such, the simple S-A threshold will vary if the rainfall-runoff behaviour of the soil changes or if the soil's erodibility changes. Over the past decades, important agronomic changes have produced significant changes in the soil use and soil management in SW Spain. It is the objective of this research to evaluate how S-A relations for gully initiation have changed over time and for two different land uses, cereal and olive. Data was collected for a gully network in the Cordoba Province, SW Spain. From photo-interpretation of historical air photos between 1956 and 2013, the gully network and initiation points were derived. In total 10 different time steps are available (1956; 1977; 1984; 1998; 2001; 2004; 2006; 2008; 2010; 2013). Topographical thresholds were extracted by combining the digitized gully network with the DEM. Due to small differences in the alignment of ortophotos and DEM, an optimization technique was developed in GIS to extract the correct S-A value for each point. With the S-A values for each year, their dynamics was evaluated as a function of land use (olive or cereal) and in function of the following variables in each of the periods considered: • soil management • soil cover by weeds, where weed growth was modeled from the daily soil water balance • rainfall intensity • root cohesion, , where root growth was modeled from the daily soil water balance We found important differences between cereal and olive and significant changes in the S-A relation over time.
Anaerobic bacteria in the intestinal microbiota of Brazilian children.
Talarico, Silvia T; Santos, Florenza E; Brandt, Katia Galeão; Martinez, Marina B; Taddei, Carla R
2017-03-01
Changes in the neonatal gut environment allow for the colonization of the mucin layer and lumen by anaerobic bacteria. The aim of the present study was to evaluate Bifidobacterium, Lactobacillus and Lactococcus colonization through the first year of life in a group of 12 Brazilian infants and to correlate these data with the levels of Escherichia coli. The presence of anaerobic members of the adult intestinal microbiota, including Eubacterium limosum and Faecalibacterium prausnitzii, was also evaluated. Fecal samples were collected during the first year of life, and 16S rRNA from anaerobic and facultative bacteria was detected by real-time PCR. Bifidobacterium was present at the highest levels at all of the studied time points, followed by E. coli and Lactobacillus. E. limosum was rarely detected, and F. prausnitzii was detected only in the samples from the latest time points. These results are consistent with reports throughout the world on the community structure of the intestinal microbiota in infants fed a milk diet. Our findings also provide evidence for the influence of the environment on intestinal colonization due to the high abundance of E. coli. The presence of important anaerobic genera was observed in Brazilian infants living at a low socioeconomic level, a result that has already been well established for infants living in developed countries.
Spatially offset raman spectroscopy for non-invasive assessment of fracture healing
NASA Astrophysics Data System (ADS)
Ding, Hao; Lu, Guijin; West, Christopher; Gogola, Gloria; Kellam, James; Ambrose, Catherine; Bi, Xiaohong
2016-02-01
Fracture non-unions and bone re-fracture are common challenges for post-fracture management. To achieve better prognosis and treatment evaluation, it is important to be able to assess the quality of callus over the time course of healing. This study evaluated the potential of spatially offset Raman spectroscopy for assessing the fracture healing process in situ. We investigated a rat model of fracture healing at two weeks and 4 weeks post fracture with a fractured femur and a contralateral control in each animal. Raman spectra were collected from the depilated thighs on both sides transcutaneously in situ with various source/detection offsets. Bone signals were recovered from SORS spectra, and then compared with those collected from bare bones. The relative intensity of mineral from fractured bone was markedly decreased compared to the control. The fractured bones demonstrated lower mineral and carbonate level and higher collagen content in the callus at the early time point. Compared to week 2, collagen mineralization and mineral carbonation increased at 4 weeks post fracture. Similarly, the material properties of callus determined by reference point indentation also increased in the 4-week group, indicating improved callus quality with time. The results from Raman analysis are in agreement with radiographic and material testing, indicating the potential of this technique in assessing fracture healing in vivo.
Küster, Eberhard; Dorusch, Falk; Vogt, Carsten; Weiss, Holger; Altenburger, Rolf
2004-07-15
Success of groundwater remediation is typically controlled via snapshot analysis of selected chemical substances or physical parameters. Biological parameters, i.e. ecotoxicological assays, are rarely employed. Hence the aim of the study was to develop a bioassay tool, which allows an on line monitoring of contaminated groundwater, as well as a toxicity reduction evaluation (TRE) of different remediation techniques in parallel and may furthermore be used as an additional tool for process control to supervise remediation techniques in a real time mode. Parallel testing of groundwater remediation techniques was accomplished for short and long time periods, by using the energy dependent luminescence of the bacterium Vibrio fischeri as biological monitoring parameter. One data point every hour for each remediation technique was generated by an automated biomonitor. The bacteria proved to be highly sensitive to the contaminated groundwater and the biomonitor showed a long standing time despite the highly corrosive groundwater present in Bitterfeld, Germany. The bacterial biomonitor is demonstrated to be a valuable tool for remediation success evaluation. Dose response relationships were generated for the six quantitatively dominant groundwater contaminants (2-chlortoluene, 1,2- and 1,4-dichlorobenzene, monochlorobenzene, ethylenbenzene and benzene). The concentrations of individual volatile organic chemicals (VOCs) could not explain the observed effects in the bacteria. An expected mixture toxicity was calculated for the six components using the concept of concentration addition. The calculated EC(50) for the mixture was still one order of magnitude lower than the observed EC(50) of the actual groundwater. The results pointed out that chemical analysis of the six most quantitative substances alone was not able to explain the effects observed with the bacteria. Thus chemical analysis alone may not be an adequate tool for remediation success evaluation in terms of toxicity reduction.
NASA Astrophysics Data System (ADS)
Xu, Y.; Sun, Z.; Boerner, R.; Koch, T.; Hoegner, L.; Stilla, U.
2018-04-01
In this work, we report a novel way of generating ground truth dataset for analyzing point cloud from different sensors and the validation of algorithms. Instead of directly labeling large amount of 3D points requiring time consuming manual work, a multi-resolution 3D voxel grid for the testing site is generated. Then, with the help of a set of basic labeled points from the reference dataset, we can generate a 3D labeled space of the entire testing site with different resolutions. Specifically, an octree-based voxel structure is applied to voxelize the annotated reference point cloud, by which all the points are organized by 3D grids of multi-resolutions. When automatically annotating the new testing point clouds, a voting based approach is adopted to the labeled points within multiple resolution voxels, in order to assign a semantic label to the 3D space represented by the voxel. Lastly, robust line- and plane-based fast registration methods are developed for aligning point clouds obtained via various sensors. Benefiting from the labeled 3D spatial information, we can easily create new annotated 3D point clouds of different sensors of the same scene directly by considering the corresponding labels of 3D space the points located, which would be convenient for the validation and evaluation of algorithms related to point cloud interpretation and semantic segmentation.
NASA Astrophysics Data System (ADS)
Pappenberger, F.; Beven, K. J.; Frodsham, K.; Matgen, P.
2005-12-01
Flood inundation models play an increasingly important role in assessing flood risk. The growth of 2D inundation models that are intimately related to raster maps of floodplains is occurring at the same time as an increase in the availability of 2D remote data (e.g. SAR images and aerial photographs), against which model performancee can be evaluated. This requires new techniques to be explored in order to evaluate model performance in two dimensional space. In this paper we present a fuzzified pattern matching algorithm which compares favorably to a set of traditional measures. However, we further argue that model calibration has to go beyond the comparison of physical properties and should demonstrate how a weighting towards consequences, such as loss of property, can enhance model focus and prediction. Indeed, it will be necessary to abandon a fully spatial comparison in many scenarios to concentrate the model calibration exercise on specific points such as hospitals, police stations or emergency response centers. It can be shown that such point evaluations lead to significantly different flood hazard maps due to the averaging effect of a spatial performance measure. A strategy to balance the different needs (accuracy at certain spatial points and acceptable spatial performance) has to be based in a public and political decision making process.
Reduction of VSC and salivary bacteria by a multibenefit mouthrinse.
Boyd, T; Vazquez, J; Williams, M
2008-03-01
To evaluate the effectiveness of a multibenefit mouthrinse containing 0.05% cetylpyridinium chloride (CPC) and 0.025% sodium fluoride in reducing volatile sulfur compound (VSC) levels and total cultivable salivary bacteria, at both 4 h and overnight. In vitro analysis of efficacy was performed using saliva-coated hydroxyapatite disc substrates first treated with the mouthrinse, then exposed to whole human saliva, followed by overnight incubation in air-tight vials. Headspace VSC was quantified by gas chromatography (GC). A clinical evaluation was conducted with 14 subjects using a crossover design. After a seven-day washout period, baseline clinical measurement of VSC was performed by GC analysis of mouth air sampled in the morning prior to eating, drinking or performing any oral hygiene. A 10 mL saline rinse was used to sample and enumerate cultivable salivary bacterial levels via serial dilution and plating. Subjects were instructed to use the treatment rinse twice daily in combination with a controlled brushing regimen. After one week the subjects returned in the morning prior to eating, drinking or performing oral hygiene to provide samples of overnight mouth air and salivary bacteria. The subjects were then immediately rinsed with the test product, and provided additional mouth air and saliva rinse samples 4 h later. A multibenefit rinse containing 0.05% CPC and 0.025% sodium fluoride was found to reduce VSC in vitro by 52%. The rinse also demonstrated a significant clinical reduction in breath VSC (p < 0.05) of 55.8% at 4 h and 23.4% overnight relative to baseline VSC levels. At both time points, the multibenefit rinse was more effective than the control; this difference was statistically significant at the overnight time point (p < 0.05). Total cultivable salivary bacteria levels were also reduced significantly (p < 0.05) at 4 h and overnight by this mouthrinse compared to baseline levels and the control. A multibenefit mouthrinse was shown to reduce in vitro VSC levels via headspace analysis and clinically at the 4 h and overnight time points. A significant reduction in total cultivable salivary bacteria was also observed at all time points, supporting the VSC data.
Performance bounds on parallel self-initiating discrete-event
NASA Technical Reports Server (NTRS)
Nicol, David M.
1990-01-01
The use is considered of massively parallel architectures to execute discrete-event simulations of what is termed self-initiating models. A logical process in a self-initiating model schedules its own state re-evaluation times, independently of any other logical process, and sends its new state to other logical processes following the re-evaluation. The interest is in the effects of that communication on synchronization. The performance is considered of various synchronization protocols by deriving upper and lower bounds on optimal performance, upper bounds on Time Warp's performance, and lower bounds on the performance of a new conservative protocol. The analysis of Time Warp includes the overhead costs of state-saving and rollback. The analysis points out sufficient conditions for the conservative protocol to outperform Time Warp. The analysis also quantifies the sensitivity of performance to message fan-out, lookahead ability, and the probability distributions underlying the simulation.
Platelet-activated clotting time does not measure platelet reactivity during cardiac surgery.
Shore-Lesserson, L; Ammar, T; DePerio, M; Vela-Cantos, F; Fisher, C; Sarier, K
1999-08-01
Platelet dysfunction is a major contributor to bleeding after cardiopulmonary bypass (CPB), yet it remains difficult to diagnose. A point-of-care monitor, the platelet-activated clotting time (PACT), measures accelerated shortening of the kaolin-activated clotting time by addition of platelet activating factor. The authors sought to evaluate the clinical utility of the PACT by conducting serial measurements of PACT during cardiac surgery and correlating postoperative measurements with blood loss. In 50 cardiac surgical patients, blood was sampled at 10 time points to measure PACT. Simultaneously, platelet reactivity was measured by the thrombin receptor agonist peptide-induced expression of P-selectin, using flow cytometry. These tests were temporally analyzed. PACT values, P-selectin expression, and other coagulation tests were analyzed for correlation with postoperative chest tube drainage. PACT and P-selectin expression were maximally reduced after protamine administration. Changes in PACT did not correlate with changes in P-selectin expression at any time interval. Total 8-h chest tube drainage did not correlate with any coagulation test at any time point except with P-selectin expression after protamine administration (r = -0.4; P = 0.03). The platelet dysfunction associated with CPB may be a result of depressed platelet reactivity, as shown by thrombin receptor activating peptide-induced P-selectin expression. Changes in PACT did not correlate with blood loss or with changes in P-selectin expression suggesting that PACT is not a specific measure of platelet reactivity.
Ideal evolution of magnetohydrodynamic turbulence when imposing Taylor-Green symmetries.
Brachet, M E; Bustamante, M D; Krstulovic, G; Mininni, P D; Pouquet, A; Rosenberg, D
2013-01-01
We investigate the ideal and incompressible magnetohydrodynamic (MHD) equations in three space dimensions for the development of potentially singular structures. The methodology consists in implementing the fourfold symmetries of the Taylor-Green vortex generalized to MHD, leading to substantial computer time and memory savings at a given resolution; we also use a regridding method that allows for lower-resolution runs at early times, with no loss of spectral accuracy. One magnetic configuration is examined at an equivalent resolution of 6144(3) points and three different configurations on grids of 4096(3) points. At the highest resolution, two different current and vorticity sheet systems are found to collide, producing two successive accelerations in the development of small scales. At the latest time, a convergence of magnetic field lines to the location of maximum current is probably leading locally to a strong bending and directional variability of such lines. A novel analytical method, based on sharp analysis inequalities, is used to assess the validity of the finite-time singularity scenario. This method allows one to rule out spurious singularities by evaluating the rate at which the logarithmic decrement of the analyticity-strip method goes to zero. The result is that the finite-time singularity scenario cannot be ruled out, and the singularity time could be somewhere between t=2.33 and t=2.70. More robust conclusions will require higher resolution runs and grid-point interpolation measurements of maximum current and vorticity.
McAleer, Stephen S; Gille, Justus; Bark, Stefan; Riepenhof, Helge
2015-08-01
The aim of this paper was to use a clinical example to describe a treatment strategy for the management of recurrent chronic groin pain and evaluate the evidence of the interventions. A professional footballer presented with chronic recurrent OP/PBS. The injury was managed successfully with a nine-point programme - 1. Acute pharmacological management. 2. Tone reduction of over-active structures. 3. Improved ROM at hips, pelvis and thorax. 4. Adductor strength. 5. Functional movement assessment. 6. Core stability. 7. Lumbo-pelvic control. 8. Gym-based strengthening. 9. Field-based conditioning/rehabilitation. The evidence for these interventions is reviewed. The player returned to full training and match play within 41 and 50 days, respectively, and experienced no recurrence of his symptoms in follow up at 13 months. This case report displays a nine-point conservative management strategy for OP/PBS, with non-time dependent clinical objective markers as the progression criteria in a Premier League football player. Copyright © 2015 Elsevier Ltd. All rights reserved.
Agreement of Tracing and Direct Viewing Techniques for Cervical Vertebral Maturation Assessment.
Wiwatworakul, Opas; Manosudprasit, Montian; Pisek, Poonsak; Chatrchaiwiwatana, Supaporn; Wangsrimongkol, Tasanee
2015-08-01
This study aimed to evaluate agreement among three methods for cervical vertebral maturation (CVM) assessment, comprising direct viewing, tracing only, and tracing with digitized points. Two examiners received training and tests of reliability with each CVM method before evaluation of agreement among methods. The subjects were 96 female-cleft lateral cephalometric radiographs (films of eight subjects for each age ranged from seven to 18 years). The examiners interpreted CVM stages of the subjects with four-week interval between uses of each method. The range of weighted kappa values for paired comparisons among the three methods were: 0.96-0.98 for direct viewing and tracing only comparison; 0.93-0.94 for direct viewing and tracing with digitized points comparison; and 0.96-0.97 for tracing only and tracing with digitized points comparison. The intraclass correlation coefficient (ICC) value among the three methods was 0.95. These results indicated very good agreement among methods. Use of direct viewing is suitable for CVM assessment without spending more time for tracing. However, the three methods might be used interchangeably.
Intensity of musculoskeletal pain and (in) ability to work in nursing.
Magnago, Tânia Solange Bosi de Souza; de Lima, Ana Cláudia Soares; Prochnow, Andrea; Ceron, Marinez Diniz da Silva; Tavares, Juliana Petri; Urbanetto, Janete de Souza
2012-01-01
the aim was to evaluate the association between the intensity of musculoskeletal pain and reduction in work ability among nursing workers. a cross-sectional study, involving 592 nursing staff in a public university hospital in Rio Grande do Sul, Brazil. The Brazilian version of the Finnish questionnaire for calculating Work Ability Index was used, whose score varies from 7 to 49 points. The score was dichotomized as reduced work ability (7 to 36 points) and good/excellent ability (37 to 49 points). The intensity of musculoskeletal pain over the previous week was evaluated, using a numerical pain scale. 43.3% of the participants had reduced work ability and 48.8% reported strong to unbearable pain. Even after adjusting for potentially confounding factors (function and length of service in the function), the workers who mentioned strong to unbearable pain were four times more likely to be classified in the group with reduced work ability. A positive association was determined between intensity of musculoskeletal pain and reduction in work ability. It is necessary to adopt intervention measures in the organizational structure, so as to promote/restore work ability.
Chen, Hui; Lowe, Alan A; de Almeida, Fernanda Riberiro; Wong, Mary; Fleetham, John A; Wang, Bangkang
2008-09-01
The aim of this study was to test a 3-dimensional (3D) computer-assisted dental model analysis system that uses selected landmarks to describe tooth movement during treatment with an oral appliance. Dental casts of 70 patients diagnosed with obstructive sleep apnea and treated with oral appliances for a mean time of 7 years 4 months were evaluated with a 3D digitizer (MicroScribe-3DX, Immersion, San Jose, Calif) compatible with the Rhinoceros modeling program (version 3.0 SR3c, Robert McNeel & Associates, Seattle, Wash). A total of 86 landmarks on each model were digitized, and 156 variables were calculated as either the linear distance between points or the distance from points to reference planes. Four study models for each patient (maxillary baseline, mandibular baseline, maxillary follow-up, and mandibular follow-up) were superimposed on 2 sets of reference points: 3 points on the palatal rugae for maxillary model superimposition, and 3 occlusal contact points for the same set of maxillary and mandibular model superimpositions. The patients were divided into 3 evaluation groups by 5 orthodontists based on the changes between baseline and follow-up study models. Digital dental measurements could be analyzed, including arch width, arch length, curve of Spee, overbite, overjet, and the anteroposterior relationship between the maxillary and mandibular arches. A method error within 0.23 mm in 14 selected variables was found for the 3D system. The statistical differences in the 3 evaluation groups verified the division criteria determined by the orthodontists. The system provides a method to record 3D measurements of study models that permits computer visualization of tooth position and movement from various perspectives.
Interrupted time series regression for the evaluation of public health interventions: a tutorial.
Bernal, James Lopez; Cummins, Steven; Gasparrini, Antonio
2017-02-01
Interrupted time series (ITS) analysis is a valuable study design for evaluating the effectiveness of population-level health interventions that have been implemented at a clearly defined point in time. It is increasingly being used to evaluate the effectiveness of interventions ranging from clinical therapy to national public health legislation. Whereas the design shares many properties of regression-based approaches in other epidemiological studies, there are a range of unique features of time series data that require additional methodological considerations. In this tutorial we use a worked example to demonstrate a robust approach to ITS analysis using segmented regression. We begin by describing the design and considering when ITS is an appropriate design choice. We then discuss the essential, yet often omitted, step of proposing the impact model a priori. Subsequently, we demonstrate the approach to statistical analysis including the main segmented regression model. Finally we describe the main methodological issues associated with ITS analysis: over-dispersion of time series data, autocorrelation, adjusting for seasonal trends and controlling for time-varying confounders, and we also outline some of the more complex design adaptations that can be used to strengthen the basic ITS design.
Interrupted time series regression for the evaluation of public health interventions: a tutorial
Bernal, James Lopez; Cummins, Steven; Gasparrini, Antonio
2017-01-01
Abstract Interrupted time series (ITS) analysis is a valuable study design for evaluating the effectiveness of population-level health interventions that have been implemented at a clearly defined point in time. It is increasingly being used to evaluate the effectiveness of interventions ranging from clinical therapy to national public health legislation. Whereas the design shares many properties of regression-based approaches in other epidemiological studies, there are a range of unique features of time series data that require additional methodological considerations. In this tutorial we use a worked example to demonstrate a robust approach to ITS analysis using segmented regression. We begin by describing the design and considering when ITS is an appropriate design choice. We then discuss the essential, yet often omitted, step of proposing the impact model a priori. Subsequently, we demonstrate the approach to statistical analysis including the main segmented regression model. Finally we describe the main methodological issues associated with ITS analysis: over-dispersion of time series data, autocorrelation, adjusting for seasonal trends and controlling for time-varying confounders, and we also outline some of the more complex design adaptations that can be used to strengthen the basic ITS design. PMID:27283160
Chacón, Jose
2010-01-01
Drug efficacy might differ from clinical trial results when performed in clinical daily conditions. Therefore, it is mandatory to conduct trials about effectiveness to improve external validity. This post-authorization, open-label, noncontrolled, prospective, multicenter, observational, and naturalistic trial was designed to search for factors influencing the racecadotril overall effect on childhood acute watery diarrhea in a real-world setting of Venezuela. There were 3,873 children with acute watery diarrhea treated with racecadotril, an enkephalin breakdown blocker plus oral rehydration therapy by 97 pediatricians. Evaluations were carried out daily until emission of two consecutive formed stools or absence of watery bowel movements for 24 hours. The primary end-point was time-to-relief, defined as the time from first racecadotril dose to the last watery bowel movement time. Age, gender, nursing type, nursing status during diarrhea, diarrhea severity, and co-medication were considered as factors in the statistical analysis. The primary end-point was evaluated by factors using UNIANOVA, and post-hoc tests were done. A multiple regression analysis was carried out to identify factors affecting drug performance, racecadotril effectiveness and tolerability overall assessment was searched by physicians and patients, and inter-observer agreement was evaluated by kappa statistics. The mean time-to-relief was 18.5 ± 12.5 hours [95% confidence interval 17.9–19.0] and the diarrhea severity was the only variable with significant and independent weight on racecadotril effectiveness explaining 23% of time-to-relief variance, but even in severe diarrhea cases this time was less than 24 hours. High agreement about satisfactory perception on effectiveness and tolerability was reached among physicians and patients. In conclusion, the racecadotril overall effect, evaluated in a real-world setting of Venezuela, was in agreement with results of some earlier controlled trials. It was only influenced by severity of diarrhea episode, as well as being considered an effective and well tolerated treatment by physicians and patients. PMID:20668711
Comparison of accelerometer cut points for predicting activity intensity in youth.
Trost, Stewart G; Loprinzi, Paul D; Moore, Rebecca; Pfeiffer, Karin A
2011-07-01
The absence of comparative validity studies has prevented researchers from reaching consensus regarding the application of intensity-related accelerometer cut points for children and adolescents. This study aimed to evaluate the classification accuracy of five sets of independently developed ActiGraph cut points using energy expenditure, measured by indirect calorimetry, as a criterion reference standard. A total of 206 participants between the ages of 5 and 15 yr completed 12 standardized activity trials. Trials consisted of sedentary activities (lying down, writing, computer game), lifestyle activities (sweeping, laundry, throw and catch, aerobics, basketball), and ambulatory activities (comfortable walk, brisk walk, brisk treadmill walk, running). During each trial, participants wore an ActiGraph GT1M, and V˙O2 was measured breath-by-breath using the Oxycon Mobile portable metabolic system. Physical activity intensity was estimated using five independently developed cut points: Freedson/Trost (FT), Puyau (PU), Treuth (TR), Mattocks (MT), and Evenson (EV). Classification accuracy was evaluated via weighted κ statistics and area under the receiver operating characteristic curve (ROC-AUC). Across all four intensity levels, the EV (κ=0.68) and FT (κ=0.66) cut points exhibited significantly better agreement than TR (κ=0.62), MT (κ=0.54), and PU (κ=0.36). The EV and FT cut points exhibited significantly better classification accuracy for moderate- to vigorous-intensity physical activity (ROC-AUC=0.90) than TR, PU, or MT cut points (ROC-AUC=0.77-0.85). Only the EV cut points provided acceptable classification accuracy for all four levels of physical activity intensity and performed well among children of all ages. The widely applied sedentary cut point of 100 counts per minute exhibited excellent classification accuracy (ROC-AUC=0.90). On the basis of these findings, we recommend that researchers use the EV ActiGraph cut points to estimate time spent in sedentary, light-, moderate-, and vigorous-intensity activity in children and adolescents.
Kim, Boong-Nyun; Kim, Jae-Won; Kim, Hyo-Won; Shin, Min-Sup; Cho, Soo-Churl; Choi, Nam Hee; Ahn, Hyunnie; Lee, Seung-Yeon; Ryu, Jeong; Yun, Myoung-Joo
2009-08-01
The aims of this study were to examine the symptoms of posttraumatic stress and anxiety/depression in Korean children after direct or indirect exposure to a single incident of trauma during a fire-escape drill and to assess the incidence of psychiatric disorders in this population. A total of 1,394 students who attended the elementary school at which the traumatic event took place were evaluated using self-administered questionnaires (the Child Posttraumatic Stress Disorder-Reaction Index [CPTSD-RI], State Anxiety Scale of the State-Trait Anxiety Inventory for Children [STAIC], and Children's Depression Inventory [CDI]), as well as structured diagnostic interviews (Diagnostic Interview Schedule for Children, Version-IV [DISC-IV]) at 2 days (time point 1), 2 months (time point 2), and 6 months (time point 3) after the incident. The 335 students who witnessed the accident were defined as the direct-exposure group, and the remaining students (n = 1,059) were defined as the indirect-exposure group. The study was conducted from May to November 2007. At time point 1, the prevalence of severe posttraumatic stress disorder (PTSD), anxiety, and depressive symptoms was 18.2%, 5.5%, and 3.4%, respectively. The prevalence of severe PTSD symptoms, as measured by the CPTSD-RI, was significantly higher in the direct-exposure group than in the indirect-exposure group (36.6% vs 12.7%, respectively; P < .001). At time point 2, the prevalence of severe PTSD symptoms was 7.4% (14.0% in the direct-exposure group and 4.9% in the indirect-exposure group, P < .001). The mean total CPTSD-RI score was significantly higher (P < .001) in the direct-exposure group than in the indirect-exposure group. At time point 3, thirty-eight of the 58 subjects (65.5%) evaluated with the DISC-IV in the direct-exposure group had 1 or more of the 7 anxiety/depressive disorders assessed, including subthreshold diagnoses. Among the diagnoses meeting full DSM-IV criteria for each disorder, agoraphobia was the most prevalent (22.4%), followed by generalized anxiety disorder (13.8%), separation anxiety disorder (6.9%), PTSD (5.2%), and social phobia (5.2%). When the subthreshold diagnoses were considered along with the full syndrome diagnoses, separation anxiety disorder was the most common diagnosis (41.4%), followed by agoraphobia (34.5%), obsessive-compulsive disorder (22.4%), PTSD (20.7%), and social phobia (20.7%). The results of this study provide important evidence that various anxiety/depressive disorders, in addition to PTSD, might follow after direct or indirect exposure to trauma. Our findings highlight the importance of comprehensive screening for psychiatric problems in children exposed to trauma of any scale. ©Copyright 2009 Physicians Postgraduate Press, Inc.
Shoemaker, Ritchie C; House, Dennis E
2006-01-01
Occupants of water-damaged buildings (WDBs) with evidence of microbial amplification often describe a syndrome involving multiple organ systems, commonly referred to as "sick building syndrome" (SBS), following chronic exposure to the indoor air. Studies have demonstrated that the indoor air of WDBs often contains a complex mixture of fungi, mycotoxins, bacteria, endotoxins, antigens, lipopolysaccharides, and biologically produced volatile compounds. A case-series study with medical assessments at five time points was conducted to characterize the syndrome after a double-blinded, placebo-controlled clinical trial conducted among a group of study participants investigated the efficacy of cholestyramine (CSM) therapy. The general hypothesis of the time series study was that chronic exposure to the indoor air of WDBs is associated with SBS. Consecutive clinical patients were screened for diagnosis of SBS using criteria of exposure potential, symptoms involving at least five organ systems, and the absence of confounding factors. Twenty-eight cases signed voluntary consent forms for participation in the time-series study and provided samples of microbial contaminants from water-damaged areas in the buildings they occupied. Twenty-six participants with a group-mean duration of illness of 11 months completed examinations at all five study time points. Thirteen of those participants also agreed to complete a double-blinded, placebo-controlled clinical trial. Data from Time Point 1 indicated a group-mean of 23 out of 37 symptoms evaluated; and visual contrast sensitivity (VCS), an indicator of neurological function, was abnormally low in all participants. Measurements of matrix metalloproteinase 9 (MMP9), leptin, alpha melanocyte stimulating hormone (MSH), vascular endothelial growth factor (VEGF), immunoglobulin E (IgE), and pulmonary function were abnormal in 22, 13, 25, 14, 1, and 7 participants, respectively. Following 2 weeks of CSM therapy to enhance toxin elimination rates, measurements at Time Point 2 indicated group-means of 4 symptoms with 65% improvement in VCS at mid-spatial frequency-both statistically significant improvements relative to Time Point 1. Moderate improvements were seen in MMP9, leptin, and VEGF serum levels. The improvements in health status were maintained at Time Point 3 following a 2-week period during which CSM therapy was suspended and the participants avoid re-exposure to the WDBs. Participants reoccupied the respective WDBs for 3 days without CSM therapy, and all participants reported relapse at Time Point 4. The group-mean number of symptoms increased from 4 at Time Point 2 to 15 and VCS at mid-spatial frequency declined by 42%, both statistically significant differences relative to Time Point 2. Statistically significant differences in the group-mean levels of MMP9 and leptin relative to Time Point 2 were also observed. CSM therapy was reinstated for 2 weeks prior to assessments at Time Point 5. Measurements at Time Point 5 indicated group-means of 3 symptoms and a 69% increase in VCS, both results statistically different from those at Time Points 1 and 4. Optically corrected Snellen Distance Equivalent visual acuity scores did not vary significantly over the course of the study. Group-mean levels of MMP9 and leptin showed statistically significant improvement at Time Point 5 relative to Time Points 1 and 4, and the proportion of participants with abnormal VEGF levels was significantly lower at Time Point 5 than at Time Point 1. The number of participants at Time Point 5 with abnormal levels of MMP9, leptin, VEGF, and pulmonary function were 10, 10, 9, and 7, respectively. The level of IgE was not re-measured because of the low incidence of abnormality at Time Point 1, and MSH was not re-measured because previously published data indicated a long time course for MSH improvement. The results from the time series study supported the general study hypothesis that exposure to the indoor air of WDBs is associated with SBS. High levels of MMP9 indicated that exposure to the complex mixture of substances in the indoor air of the WDBs triggered a pro-inflammatory cytokine response. A model describing modes of action along a pathway leading to biotoxin-associated illness is presented to organize current knowledge into testable hypotheses. The model links an inflammatory response with tissue hypoxia, as indicated by abnormal levels of VEGF, and disruption of the proopiomelanocortin pathway in the hypothalamus, as evidenced by abnormalities in leptin and MSH levels. Results from the clinical trial on CSM efficacy indicated highly significant improvement in group-mean number of symptoms and VCS scores relative to baseline in the 7 participants randomly assigned to receive 2 weeks of CSM therapy, but no improvement in the 6 participants assigned placebo therapy during that time interval. However, those 6 participants also showed a highly significant improvement in group-mean number of symptoms and VCS scores relative to baseline following a subsequent 2-week period of CSM therapy. Because the only known benefit of CSM therapy is to enhance the elimination rates of substances that accumulate in bile by preventing re-absorption during enterohepatic re-circulation, results from the clinical trial also supported the general study hypothesis that SBS is associated with exposure to WDBs because the only relevant function of CSM is to bind and remove toxigenic compounds. Only research that focuses on the signs, symptoms, and biochemical markers of patients with persistent illness following acute and/or chronic exposure to WDBs can further the development of the model describing modes of action in the biotoxin-associated pathway and guide the development of innovative and efficacious therapeutic interventions.
High‐resolution trench photomosaics from image‐based modeling: Workflow and error analysis
Reitman, Nadine G.; Bennett, Scott E. K.; Gold, Ryan D.; Briggs, Richard; Duross, Christopher
2015-01-01
Photomosaics are commonly used to construct maps of paleoseismic trench exposures, but the conventional process of manually using image‐editing software is time consuming and produces undesirable artifacts and distortions. Herein, we document and evaluate the application of image‐based modeling (IBM) for creating photomosaics and 3D models of paleoseismic trench exposures, illustrated with a case‐study trench across the Wasatch fault in Alpine, Utah. Our results include a structure‐from‐motion workflow for the semiautomated creation of seamless, high‐resolution photomosaics designed for rapid implementation in a field setting. Compared with conventional manual methods, the IBM photomosaic method provides a more accurate, continuous, and detailed record of paleoseismic trench exposures in approximately half the processing time and 15%–20% of the user input time. Our error analysis quantifies the effect of the number and spatial distribution of control points on model accuracy. For this case study, an ∼87 m2 exposure of a benched trench photographed at viewing distances of 1.5–7 m yields a model with <2 cm root mean square error (rmse) with as few as six control points. Rmse decreases as more control points are implemented, but the gains in accuracy are minimal beyond 12 control points. Spreading control points throughout the target area helps to minimize error. We propose that 3D digital models and corresponding photomosaics should be standard practice in paleoseismic exposure archiving. The error analysis serves as a guide for future investigations that seek balance between speed and accuracy during photomosaic and 3D model construction.
NASA Astrophysics Data System (ADS)
Noreen, Amna; Olaussen, Kåre
2012-10-01
A subroutine for a very-high-precision numerical solution of a class of ordinary differential equations is provided. For a given evaluation point and equation parameters the memory requirement scales linearly with precision P, and the number of algebraic operations scales roughly linearly with P when P becomes sufficiently large. We discuss results from extensive tests of the code, and how one, for a given evaluation point and equation parameters, may estimate precision loss and computing time in advance. Program summary Program title: seriesSolveOde1 Catalogue identifier: AEMW_v1_0 Program summary URL: http://cpc.cs.qub.ac.uk/summaries/AEMW_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 991 No. of bytes in distributed program, including test data, etc.: 488116 Distribution format: tar.gz Programming language: C++ Computer: PC's or higher performance computers. Operating system: Linux and MacOS RAM: Few to many megabytes (problem dependent). Classification: 2.7, 4.3 External routines: CLN — Class Library for Numbers [1] built with the GNU MP library [2], and GSL — GNU Scientific Library [3] (only for time measurements). Nature of problem: The differential equation -s2({d2}/{dz2}+{1-ν+-ν-}/{z}{d}/{dz}+{ν+ν-}/{z2})ψ(z)+{1}/{z} ∑n=0N vnznψ(z)=0, is solved numerically to very high precision. The evaluation point z and some or all of the equation parameters may be complex numbers; some or all of them may be represented exactly in terms of rational numbers. Solution method: The solution ψ(z), and optionally ψ'(z), is evaluated at the point z by executing the recursion A(z)={s-2}/{(m+1+ν-ν+)(m+1+ν-ν-)} ∑n=0N Vn(z)A(z), ψ(z)=ψ(z)+A(z), to sufficiently large m. Here ν is either ν+ or ν-, and Vn(z)=vnz. The recursion is initialized by A(z)=δzν,for n=0,1,…,N ψ(z)=A0(z). Restrictions: No solution is computed if z=0, or s=0, or if ν=ν- (assuming Reν+≥Reν-) with ν+-ν- an integer, except when ν+-ν-=1 and v =0 (i.e. when z is an ordinary point for zψ(z)). Additional comments: The code of the main algorithm is in the file seriesSolveOde1.cc, which "#include" the file checkForBreakOde1.cc. These routines, and the programs using them, must "#include" the file seriesSolveOde1.cc. Running time: On a Linux PC that is a few years old, at y=√{10} to an accuracy of P=200 decimal digits, evaluating the ground state wavefunction of the anharmonic oscillator (with the eigenvalue known in advance); (cf. Eq. (6)) takes about 2 ms, and about 40 min at an accuracy of P=100000 decimal digits. References: [1] B. Haible and R.B. Kreckel, CLN — Class Library for Numbers, http://www.ginac.de/CLN/ [2] T. Granlund and collaborators, GMP — The GNU Multiple Precision Arithmetic Library, http://gmplib.org/ [3] M. Galassi et al., GNU Scientific Library Reference Manual (3rd Ed.), ISBN 0954612078., http://www.gnu.org/software/gsl/
48 CFR 52.247-46 - Shipping Point(s) Used in Evaluation of F.o.b. Origin Offers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Evaluation of F.o.b. Origin Offers. 52.247-46 Section 52.247-46 Federal Acquisition Regulations System... Text of Provisions and Clauses 52.247-46 Shipping Point(s) Used in Evaluation of F.o.b. Origin Offers. As prescribed in 47.305-3(b)(4)(ii), insert the following provision in f.o.b. origin solicitations...
Innovation, Nostalgia, and the Politics of Educational Change. Responses
ERIC Educational Resources Information Center
Labaree, David F.
2006-01-01
In this reaction, the author concentrates on evaluating the study's broader interpretive claims. He states that the articles reviewed have the following three purposes: (1) to explore the ways in which a variety of factors shape school change over time; (2) to show how the five factors combine at key points in the story to create what Ivor…
Dementia in Adults with Mental Retardation: Assessment at a Single Point in Time
ERIC Educational Resources Information Center
Silverman, Wayne; Schupf, Nicole; Zigman, Warren; Devenny, Darlynne; Miezejeski, Charles; Schubert, Romaine; Ryan, Robert
2004-01-01
Dementia status of 273 adults with mental retardation was rated based upon two extensive evaluations conducted 18 months apart. Overall, 184 individuals did not have dementia, 33 had possible or definite dementia, and 66 had findings suggesting uncertain or questionable status. These ratings were compared to binary classifications (dementia vs. no…
Managing coastal recreation impacts and visitor experience using GIS
Anna M. T. Gajda; Judson Brown; Grant Peregoodoff; Patrick Bartier
2000-01-01
A campsite monitoring program was initiated in Gwaii Haanas National Park Reserve/Haida Heritage Site to determine baseline levels of visitor impacts. These data were necessary to evaluate visitor management strategies and to act as reference points to measure changes in impacts over time. Using GIS, survey data were integrated with an ecological land classification,...
Jae-Won Lee; Rita C.L.B. Rodrigues; Thomas W. Jeffries
2009-01-01
Response surface methodology was used to evaluate optimal time, temperature and oxalic acid concentration for simultaneous saccharification and fermentation (SSF) of corncob particles by Pichia stipitis CBS 6054. Fifteen different conditions for pretreatment were examined in a 23 full factorial design with six axial points. Temperatures ranged from 132 to 180º...
Sustainability by Education: How Latvian Heritage Was Kept Alive in German Exile
ERIC Educational Resources Information Center
Franzenburg, Geert
2016-01-01
Sustainability is one of the core challenges for education in modern times, particularly concerning cultural heritage. The study evaluates, from a German point of view, how Latvians outside of Latvia after World War II kept their cultural heritage alive by educational concepts, which can be characterized as early roots of modern sustainable…
ERIC Educational Resources Information Center
Porter, Kristin E.
2016-01-01
In education research and in many other fields, researchers are often interested in testing the effectiveness of an intervention on multiple outcomes, for multiple subgroups, at multiple points in time, or across multiple treatment groups. The resulting multiplicity of statistical hypothesis tests can lead to spurious findings of effects. Multiple…
Evaluating rapid response to a goldspotted oak borer diaspora
Tom Scott; Kevin Turner
2015-01-01
In 2012, the goldspotted oak borer (Agrilus auroguttatus, GSOB) was discovered in the mountain community of Idyllwild, 56.3 km north of its known area of infestation. This was the third time that a point of outbreak was discovered >32.2 km from the GSOB infestation area, suggesting that human transport of GSOB has substantially expanded the...
The procedures manual of the Environmental Measurements Laboratory. Volume 2, 28. edition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chieco, N.A.
1997-02-01
This report contains environmental sampling and analytical chemistry procedures that are performed by the Environmental Measurements Laboratory. The purpose of environmental sampling and analysis is to obtain data that describe a particular site at a specific point in time from which an evaluation can be made as a basis for possible action.
ERIC Educational Resources Information Center
Hays, Ron D.; And Others
1994-01-01
Applied structural equation modeling to evaluation of cross-lagged panel models. Self-reports of physical and mental health at three time points spanning four-year interval were analyzed to illustrate cross-lagged analysis methodology. Data were analyzed from 856 patients with hypertension, diabetes, heart disease, or depression. Cross-lagged…
Using Norm-Based Appeals to Increase Response Rates in Evaluation Research: A Field Experiment
ERIC Educational Resources Information Center
Misra, Shalini; Stokols, Daniel; Marino, Anne Heberger
2012-01-01
A field experiment was conducted to test the effectiveness of norm-based persuasive messages for increasing response rates in online survey research. Participants in an interdisciplinary conference were asked to complete two successive postconference surveys and randomly assigned to one of two groups at each time point. The experimental group…
Markvardsen, L H; Harbo, T; Sindrup, S H; Christiansen, I; Andersen, H; Jakobsen, J
2014-12-01
Subcutaneous immunoglobulin (SCIG) is superior to placebo treatment for maintenance of muscle strength during 12 weeks in patients with chronic inflammatory demyelinating polyneuropathy (CIDP). The present study evaluated whether SCIG preserves muscle strength for 1 year in an open-label follow-up study. Seventeen responders to intravenous immunoglobulin (IVIG) who had participated in the previous study of SCIG versus placebo in CIDP were included. After one IVIG infusion 2 weeks prior to baseline, all continued on SCIG treatment at weekly equal dosage and were evaluated after 3, 6 and 12 months. Primary end-points were changes in muscle strength evaluated by isokinetic dynamometry in four affected muscle groups and a composite score of muscle performance and function tests, including Medical Research Council (MRC) score, grip strength, 40-m walking test (40-MWT) and nine-hole peg test (9-HPT). Secondary end-points were changes of each of the listed parameters at each time point as well as an overall disability sum score (ODSS). The dose of SCIG was significantly unaltered during the follow-up period. Overall the isokinetic dynamometry value increased by 7.2% (P = 0.033) and after 3, 6 and 12 months by 5.7%, 8.2% and 6.8% (ns). The overall composite score at all time intervals and for each interval remained unchanged. Amongst the secondary parameters the MRC score increased significantly by 1.7% (P = 0.007), whereas grip strength, 40-MWT, 9-HPT and ODSS remained unchanged. SCIG preserves muscle strength and functional ability in patients with CIDP who previously responded to IVIG. SCIG should be considered as an alternative in long-term treatment of CIDP patients. © 2014 The Author(s) European Journal of Neurology © 2014 EAN.
Ciulla, T A; Criswell, M H; Snyder, W J; Small, W
2005-01-01
Aim: The new photosensitiser PhotoPoint MV6401, indium chloride methyl pyropheophorbide, was assessed as a possible ocular photodynamic therapy agent in a rat model of experimentally induced corneal neovascularisation and in choriocapillaris closure in the rabbit. Optimal drug and light activation parameters were determined. Methods: MV6401 (Miravant Pharmaceuticals, Inc, Santa Barbara, CA, USA) was activated at 664 nm using a DD3-0665 (Miravant Systems Inc) 0.5 W diode laser. Corneal neovascularisation in rats was induced using an N-heptanol technique. The evaluated drug dosages, light dosages, and post-injection activation times ranged from 0.01–0.1 μmol/kg, 5–25 J/cm2, and 10–60 minutes, respectively. The efficacy of MV6401 on normal choriocapillaris and choroidal vessels was evaluated in rabbits with indirect ophthalmoscopy, fundus photography, fluorescein angiography, and histology. In rabbits, the evaluated drug dosages, light dosages, and post-injection activation times ranged from 0.025–0.25 μmol/kg, 3.3–20 J/cm2, and 10 minutes, respectively. Results: In the rat corneal neovascularisation model, an optimal intravenous drug dosage of 0.075 μmol/kg was activated by a 20 J/cm2 light dose at 10 minutes after drug administration, the results of which demonstrated early evidence of efficacy in ocular neovascularisation. In rabbits, closure of the normal choriocapillaris was selectively achieved at a drug dosage of 0.15 μmol/kg using light doses from 3.3 to 20 J/cm2. Conclusion: PhotoPoint MV6401 is a potent photosensitiser that demonstrates both efficacy and selectivity in experimental ocular models. PMID:15615758
Ciulla, T A; Criswell, M H; Snyder, W J; Small, W
2005-01-01
The new photosensitiser PhotoPoint MV6401, indium chloride methyl pyropheophorbide, was assessed as a possible ocular photodynamic therapy agent in a rat model of experimentally induced corneal neovascularisation and in choriocapillaris closure in the rabbit. Optimal drug and light activation parameters were determined. MV6401 (Miravant Pharmaceuticals, Inc, Santa Barbara, CA, USA) was activated at 664 nm using a DD3-0665 (Miravant Systems Inc) 0.5 W diode laser. Corneal neovascularisation in rats was induced using an N-heptanol technique. The evaluated drug dosages, light dosages, and post-injection activation times ranged from 0.01-0.1 micromol/kg, 5-25 J/cm(2), and 10-60 minutes, respectively. The efficacy of MV6401 on normal choriocapillaris and choroidal vessels was evaluated in rabbits with indirect ophthalmoscopy, fundus photography, fluorescein angiography, and histology. In rabbits, the evaluated drug dosages, light dosages, and post-injection activation times ranged from 0.025-0.25 micromol/kg, 3.3-20 J/cm(2), and 10 minutes, respectively. In the rat corneal neovascularisation model, an optimal intravenous drug dosage of 0.075 micromol/kg was activated by a 20 J/cm(2) light dose at 10 minutes after drug administration, the results of which demonstrated early evidence of efficacy in ocular neovascularisation. In rabbits, closure of the normal choriocapillaris was selectively achieved at a drug dosage of 0.15 micromol/kg using light doses from 3.3 to 20 J/cm(2). PhotoPoint MV6401 is a potent photosensitiser that demonstrates both efficacy and selectivity in experimental ocular models.
Turró-Garriga, Oriol; Calvó-Perxas, Laia; Vilalta-Franch, Joan; Hernández-Ferrándiz, Marta; Flaqué, Margarita; Linares, Marta; Cullell, Marta; Gich, Jordi; Casas, Isabel; Perkal, Héctor; Garre-Olmo, Josep
2017-01-01
There are several position statements and clinical practice guidelines (CPG) for diagnosing dementia. Our aims were to evaluate the adherence to CPG among specialists in the 7 memory clinics included in the Registry of Dementias of Girona (ReDeGi), and to compare the results between 2007-2011 and 2012-2015. We also determined the time and number of visits required to achieve a diagnosis, the supplementary tests ordered, and the drugs prescribed according to dementia subtypes. Medical charts of a stratified random sample of 475 ReDeGi cases were reviewed. Basic dementia work-up was evaluated using as a reference evidence-based CPG. An Index of Adherence (AI) was calculated using the following items in the medical chart: cognitive symptomatology; functional disability evaluation; physical examination; neurological examination; psychiatric examination; brief cognitive examination; activities of daily living performance examination; blood test; structural neuroimaging (CT-scan or MRI). The mean AI to CPG among specialists was of 8.2 points, and it improved from 7.9 points in 2007-2011 to 8.5 points in 2012-2015 (Cohen's d = 0.46). A lower adherence was detected in the most severe cases. A dementia diagnosis required 3.5 visits, regardless of the subtype of dementia, although milder cases required more time, more visits, and more supplementary tests than severe cases. The adherence to CPG in the catchment area of the ReDeGi is high, and an epidemiological surveillance system such as the ReDeGi may help in improving it. Dementia guidelines should establish procedures adapted to clinical practice, with simplified recommendations for most severe cases.
Oshikiri, Taro; Yasuda, Takashi; Yamamoto, Masashi; Kanaji, Shingo; Yamashita, Kimihiro; Matsuda, Takeru; Sumi, Yasuo; Nakamura, Tetsu; Fujino, Yasuhiro; Tominaga, Masahiro; Suzuki, Satoshi; Kakeji, Yoshihiro
2016-09-01
Minimally invasive esophagectomy (MIE) has less morbidity than the open approach. In particular, thoracoscopic esophagectomy in the prone position (TEP) has been performed worldwide. Using the cumulative sum control chart (CUSUM) method, this study aimed to confirm whether a trainee surgeon who learned established standards would become skilled in TEP with a shorter learning curve than that of the mentoring surgeon. Surgeon A performed TEP in 100 patients; the first 22 patients comprised period 1. His learning curve, defined based on the operation time (OT) of the thoracic procedure, was evaluated using the CUSUM method, and short-term outcomes were assessed. Another 22 patients underwent TEP performed by surgeon B, with outcomes compared to those of surgeon A's period 1. Using the CUSUM chart, the peak point of the thoracic procedure OT occurred at the 44th case in surgeon A's experience of 100 cases. With surgeon A's first 22 cases (period 1), the peak point of the thoracic procedure OT could not be confirmed and graph is expanding soaring at CUSUM chart. The CUSUM chart of surgeon B's experience of 22 cases clearly indicated that the peak point of the thoracic procedure OT occurred at the 17th case. The rate of recurrent laryngeal nerve palsy for surgeon B (9 %) was significantly lower than for surgeon A in period 1 (36 %) (p = 0.0266). There is some possibility for a trainee surgeon to attain the required basic skills to perform TEP in a relatively short period of time using a standardized procedure developed by a mentoring surgeon. The CUSUM method should be useful in evaluating trainee competence during an initial series of procedures, by assessing the learning curve defined by OT.
NASA Astrophysics Data System (ADS)
Park, Young Woo; Guo, Bing; Mogensen, Monique; Wang, Kevin; Law, Meng; Liu, Brent
2010-03-01
When a patient is accepted in the emergency room suspected of stroke, time is of the utmost importance. The infarct brain area suffers irreparable damage as soon as three hours after the onset of stroke symptoms. A CT scan is one of standard first line of investigations with imaging and is crucial to identify and properly triage stroke cases. The availability of an expert Radiologist in the emergency environment to diagnose the stroke patient in a timely manner only increases the challenges within the clinical workflow. Therefore, a truly zero-footprint web-based system with powerful advanced visualization tools for volumetric imaging including 2D. MIP/MPR, 3D display can greatly facilitate this dynamic clinical workflow for stroke patients. Together with mobile technology, the proper visualization tools can be delivered at the point of decision anywhere and anytime. We will present a small pilot project to evaluate the use of mobile technologies using devices such as iPhones in evaluating stroke patients. The results of the evaluation as well as any challenges in setting up the system will also be discussed.
Barbosa, Flávia Isabela; Araújo, Patrícia Valente; Machado, Lucas José Campos; Magalhães, Cláudia Silami; Guimarães, Milena Maria Moreira; Moreira, Allyson Nogueira
2018-04-27
This pilot study aimed to evaluate the effect of antimicrobial photodynamic therapy (aPDT) as an adjuvant to non-surgical periodontal therapy (NSPT) on periodontal status and glycemic control in patients with type 2 diabetes mellitus and generalized chronic periodontitis. Twelve patients were evaluated at five time points: during the preparation of the patient (T0), during the treatment phase (T1) and after 30 (T2), 90 (T3) and 180 (T4) days. The patients had a mean age of 52.2 years and a 9.58-year history of diabetes, on average, and were divided into two randomized treatment groups: 6 patients received NSPT combined with aPDT (G1) and 6 patients received only NSPT (G2). The aPDT was applied associating the photosensitizing agent methylene blue (10 mg/ ml) with a red laser (660 nm- 40 mW). The total time of exposure was 2 min per tooth. Whitin the limitation of this study, the results showed that the plaque index reduced significantly only in the control group (p = 0.02) at T2 (30 days). For bleeding on probing, both groups showed a significant reduction between T1 and T2, with no difference between groups G1 and G2. Regarding the probing depth, there were no differences between groups, but the parameters decreased over time when compared to T1. The glycated haemoglobin and fructosamine levels did not significantly differ between or within the groups at any time point. When NSPT was combined with aPDT, no additional benefits were observed for the periodontal and metabolic clinical parameters. Copyright © 2018. Published by Elsevier B.V.
Palma, Beatriz Duarte; Tufik, Sergio
2010-01-01
Study Objectives: The aim of this study was to evaluate sleep patterns during the course of the disease in (NZB/NZW)F1 mice, an experimental model of systemic lupus erythematosus (SLE). Design: Female mice were implanted with electrodes for chronic recording of sleep-wake cycles during the entire experimental phase (9, 19, and 29 weeks of age). The disease course was also assessed. At each time-point, blood samples were collected from the orbital plexus to evaluate serum antinuclear antibodies (ANA), which are important serologic parameters of disease evolution. Pain perception was also evaluated. Measurements and Results: During the dark phase, (NZB/NZW)F1 mice aged 19 weeks spent more time in sleep, and, as a consequence, the total waking time was lower when compared with earlier periods. An augmented number of sleep-stage transitions and microarousals were observed at the 29th week of life in both light and dark phases. At this same time-point, the mice showed lower pain thresholds than they had at 9 weeks of life. The disease status was confirmed; the entire group of mice at 29 weeks of life showed positive ANA with high titer levels. Conclusions: The sleep-recording data showed that, during the progress and severe phases of the disease (19 and 29 wks of age, respectively), sleep architecture is altered. According to these results, increased sleep fragmentation, disease activity, and pain sensitivity are features observed in these mice, similar to symptoms of SLE. Citation: Palma BD; Tufik S. Increased disease activity is associated with altered sleep architecture in an experimental model of systemic lupus erythematosus. SLEEP 2010;33(9):1244-1248. PMID:20857872
Doty, Rosalinda A; Liu, Jia; McFadden, Grant; Roy, Edward J; MacNeill, Amy L
2013-01-01
Two recombinant myxoma viruses (MYXV expressing a fluorescent protein [MYXV-Tred] and MYXV-Tred encoding murine interleukin-15 [MYXV-IL15]) were evaluated for therapeutic effects in an aggressive B16F10 melanoma model in immunocompetent mice. It was hypothesized that continuous expression of IL-15 within a tumor would recruit cytotoxic effector cells to induce an antitumor immune response and improve treatment efficacy. Weekly intratumoral injections were given to evaluate the effect of treatment on the median survival time of C57BL/6 mice bearing established B16F10 melanomas. Mice that received MYXV-Tred or MYXV-IL15 lived significantly longer than mice given treatment controls. Unexpectedly, the median survival time of MYXV-IL15-treated mice was similar to that of MYXV-treated mice. At 1, 2, and 4 days postinoculation, viral plaque assays detected replicating MYXV-Tred and MYXV-IL15 within treated tumors. At these time points in MYXV-IL15-treated tumors, IL-15 concentration, lymphocyte grades, and cluster of differentiation-3+ cell counts were significantly increased when compared to other treatment groups. However, viral titers, recombinant protein expression, and lymphocyte numbers within the tumors diminished rapidly at 7 days postinoculation. These data indicate that treatment with recombinant MYXV should be repeated at least every 4 days to maintain recombinant protein expression within a murine tumor. Additionally, neutrophilic inflammation was significantly increased in MYXV-Tred- and MYXV-IL15-treated tumors at early time points. It is speculated that neutrophilic inflammation induced by intratumoral replication of recombinant MXYV contributes to the antitumoral effect of MYXV treatment in this melanoma model. These findings support the inclusion of neutrophil chemotaxins in recombinant poxvirus oncolytic virotherapy. PMID:25866742
Stephens, Christopher B; Spackman, Erica
2017-09-15
Removal of contaminated material from a poultry house during recovery from an avian influenza virus (AIV) outbreak is costly and labor intensive. Because AIV is not environmentally stable, heating poultry houses may provide an alternative disinfection method. The objective was to determine the time necessary to inactivate AIV in poultry litter at temperatures achievable in a poultry house. Low pathogenic (LP) AIV inactivation was evaluated between 10.0°-48.9°C, at ∼5.5°C intervals and highly pathogenic (HP) AIV inactivation was evaluated between 10.0°-43.3°C, at ∼11°C intervals. Samples were collected at numerous time points for each temperature. Virus isolation in embryonating chicken eggs was conducted to determine if viable virus was present. Each sample was also tested by real-time RT-PCR. Low pathogenicity AIV was inactivated at 1day at 26.7°C or above. At 10.0, 15.6 and 21.1°C, inactivation times increased to 2-5days. Highly pathogenic AIV followed a similar trend; the virus was inactivated after 1day at 43.3°C and 32.2°C, and required 2 and 5days for inactivation at 21.1°C and 10.0°C respectively. While low pathogenicity AIV appeared to be inactivated at a lower temperature than high pathogenicity AIV, this was not due to any difference in the strains, but due to fewer temperature points being evaluated for high pathogenicity. Endpoints for detection by real-time RT-PCR were not found even weeks after the virus was inactivated. This provides a guideline for the time required, at specific temperatures to inactivate AIV in poultry litter and likely on surfaces within the house. Heat treatment will provide an added level of safety to personnel and against further spread by eliminating infectious virus prior to cleaning a house. Published by Elsevier B.V.
Cawello, Willi; Bökens, Hilmar; Nickel, Brunhild; Andreas, Jens-Otto; Halabi, Atef
2013-01-01
To test for bioequivalence of 200 mg lacosamide oral tablet and syrup formulations. Additional objectives were to compare the pharmacokinetic profile of lacosamide in saliva and plasma, and to evaluate its tolerability. This open-label, randomized, two-way crossover trial was conducted in 16 healthy Caucasian male participants in Germany. The bioequivalence of 200 mg lacosamide tablet and syrup was evaluated using plasma to determine maximum measured concentration (C(max)) and area under the curve from zero to the last time point (AUC)(0-tz). Plasma and saliva samples for evaluation of pharmacokinetic parameters of lacosamide and the major metabolite O-desmethyl lacosamide (SPM 12809) were taken over 15 time points (0.5-72 h) and used to statistically compare bioavailability of the two. Urine samples were collected predose and over five time points (0-48 h) to evaluate the cumulative amount of unchanged drug and metabolite. Lacosamide median time to reach C(max) (t(max)) was 1 h for tablet and 0.5 h for syrup in plasma and saliva. Mean terminal half life (t(½)) for tablet and syrup was 12.5 and 12.4 h in plasma, and 13.1 and 13.3 h in saliva, respectively. Tablet and syrup mean plasma AUC(0-tz) was 84.5 and 83.3 μg/mL*h, respectively. Mean AUC(0-tz) in saliva was 93.2 μg/mL*h for tablet and syrup. Mean C(max) for tablet was 5.26 μg/mL in plasma and 5.63 μg/mL in saliva. Syrup mean C(max) was 5.14 and 8.32 μg/mL in plasma and saliva, respectively. Within 2 h of syrup administration, elevated lacosamide concentration in saliva compared to plasma was observed. The ratio of lacosamide syrup to tablet was 0.98 for C(max) and 0.99 for AUC(0-tz) in plasma, and 1.00 for AUC((0-tz)) in saliva; the 90% confidence intervals (CIs) for these parameters were within the range of 0.80-1.25, which meets accepted bioequivalence criteria. The syrup-to-tablet ratio for C(max) in saliva was 1.48, and the 90% CIs exceeded the accepted upper boundary for bioequivalence (1.32-1.66). Both formulations were well tolerated. Metabolite concentration versus time profiles for saliva were similar to plasma following tablet and syrup administration. The tablet and syrup formulations of lacosamide 200 mg were bioequivalent and well tolerated. Saliva samples were demonstrated to be a suitable surrogate to evaluate lacosamide tablet pharmacokinetics in the central compartment. Due to residual syrup in the buccal cavity, limitations exist when using saliva to evaluate the pharmacokinetics of lacosamide syrup <2 h after administration. Wiley Periodicals, Inc. © 2012 International League Against Epilepsy.
2018-01-01
Background Any system applied to the control of parenteral nutrition (PN) ought to prove that the process meets the established requirements and include a repository of records to allow evaluation of the information about PN processes at any time. Objective The goal of the research was to evaluate the mobile health (mHealth) app and validate its effectiveness in monitoring the management of the PN process. Methods We studied the evaluation and validation of the general process of PN using an mHealth app. The units of analysis were the PN bags prepared and administered at the Son Espases University Hospital, Palma, Spain, from June 1 to September 6, 2016. For the evaluation of the app, we used the Poststudy System Usability Questionnaire and subsequent analysis with the Cronbach alpha coefficient. Validation was performed by checking the compliance of control for all operations on each of the stages (validation and transcription of the prescription, preparation, conservation, and administration) and by monitoring the operative control points and critical control points. Results The results obtained from 387 bags were analyzed, with 30 interruptions of administration. The fulfillment of stages was 100%, including noncritical nonconformities in the storage control. The average deviation in the weight of the bags was less than 5%, and the infusion time did not present deviations greater than 1 hour. Conclusions The developed app successfully passed the evaluation and validation tests and was implemented to perform the monitoring procedures for the overall PN process. A new mobile solution to manage the quality and traceability of sensitive medicines such as blood-derivative drugs and hazardous drugs derived from this project is currently being deployed. PMID:29615389
Self-assessment through videotaping compared with peer and trainer feedback.
Avsar, Ummu Zeynep; Cansever, Zeliha; Acemoglu, Hamit; Avsar, Umit; Khan, Abdul Sattar; Cayir, Yasemin
2015-01-01
To assess and compare three different types of feedback for presentation skills, self, peer and trainer feedback. Cross-sectional study. Faculty of Medicine at Atatürk University, Erzurum, Turkey, from March 2012 to December 2012. Participants were faculty members and instructor nurses. Each participant gave a 10-minute presentation, which was rated by peers, course trainers and the presenter himself/herself using a thirteen-item questionnaire (designed as a 5-point Likert scale). Peers and trainers conducted the assessment during the presentation while the self-assessment was done later by watching a video recording of the presentation. Comparison of the points between the groups was made using the two-way ANOVA. Pearson correlation analysis was conducted to evaluate the relationship between the mean scores of self-assessment, peer and trainer assessment. Ten faculty members, 27 instructor nurses and 4 trainers participated in the study. A total of 775 feedback reports were collected for 37 participants. There was no significant difference between the feedback scores of the evaluators as well as the occupation groups (p > 0.05). There was a strong positive and statistically significant correlation between trainer and peer (r = 0.73, p < 0.001). Consequently, there were no differences in the evaluations of presentation skills between different stakeholders. Trainers should use the video recording method to self-evaluate their presentation skills, and they should invite their peers from time to time to improve their own personal development by using peer review methods.
Taffarel, Marilda Onghero; Luna, Stelio Pacca Loureiro; de Oliveira, Flavia Augusta; Cardoso, Guilherme Schiess; Alonso, Juliana de Moura; Pantoja, Jose Carlos; Brondani, Juliana Tabarelli; Love, Emma; Taylor, Polly; White, Kate; Murrell, Joanna C
2015-04-01
Quantification of pain plays a vital role in the diagnosis and management of pain in animals. In order to refine and validate an acute pain scale for horses a prospective, randomized, blinded study was conducted. Twenty-four client owned adult horses were recruited and allocated to one of four following groups: anaesthesia only (GA); pre-emptive analgesia and anaesthesia (GAA,); anaesthesia, castration and postoperative analgesia (GC); or pre-emptive analgesia, anaesthesia and castration (GCA). One investigator, unaware of the treatment group, assessed all horses at time-points before and after intervention and completed the pain scale. Videos were also obtained at these time-points and were evaluated by a further four blinded evaluators who also completed the scale. The data were used to investigate the relevance, specificity, criterion validity and inter- and intra-observer reliability of each item on the pain scale, and to evaluate construct validity and responsiveness of the scale. Construct validity was demonstrated by the observed differences in scores between the groups, four hours after anaesthetic recovery and before administration of systemic analgesia in the GC group. Inter- and intra-observer reliability for the items was only satisfactory. Subsequently the pain scale was refined, based on results for relevance, specificity and total item correlation. Scale refinement and exclusion of items that did not meet predefined requirements generated a selection of relevant pain behaviours in horses. After further validation for reliability, these may be used to evaluate pain under clinical and experimental conditions.
Covassin, Tracey; Petit, Kyle M; Savage, Jennifer L; Bretzin, Abigail C; Fox, Meghan E; Walker, Lauren F; Gould, Daniel
2018-06-01
Sports-related concussion (SRC) injury rates, and identifying those athletes at the highest risk, have been a primary research focus. However, no studies have evaluated at which time point during an athletic event athletes are most susceptible to SRCs. To determine the clinical incidence of SRCs during the start, middle, and end of practice and competition among high school male and female athletes in the state of Michigan. Descriptive epidemiological study. There were 110,774 male and 71,945 female student-athletes in grades 9 through 12 (mean time in high school, 2.32 ± 1.1 years) who participated in sponsored athletic activities (13 sports) during the 2015-2016 academic year. An SRC was diagnosed and managed by a medical professional (ie, MD, DO, PA, NP). SRC injuries were reported by certified athletic trainers, athletic administrators, and coaches using the Michigan High School Athletic Association Head Injury Reporting System. Time of SRC was defined as the beginning, middle, or end of practice/competition. Clinical incidence was calculated by dividing the number of SRCs in a time point (eg, beginning) by the total number of participants in a sport per 100 student-athletes (95% CI). Risk ratios were calculated by dividing one time point by another time point. There were 4314 SRCs reported, with the highest in football, women's basketball, and women's soccer. The total clinical incidence for all sports was 2.36 (95% CI, 2.29-2.43) per 100 student-athletes. The most common time for SRCs was the middle, followed by the end of all events. Athletes had a 4.90 (95% CI, 4.44-5.41) and 1.50 (95% CI, 1.40-1.60) times greater risk during the middle of all events when compared with the beginning and end, respectively. There was a 3.28 (95% CI, 2.96-3.63) times greater risk at the end of all events when compared with the beginning. Athletes were at the greatest risk for SRCs at the middle of practice and competition when compared with the beginning and end. The current study suggests that medical attention is particularly important during the middle of all athletic events. Intervention measures to limit SRCs may be most beneficial during the middle of athletic events.
Critical Events in the Lives of Interns
Graham, Mark; Schmidt, Hilary; Stern, David T.; Miller, Steven Z.
2008-01-01
BACKGROUND Early residency is a crucial time in the professional development of physicians. As interns assume primary care for their patients, they take on new responsibilities. The events they find memorable during this time could provide us with insight into their developing professional identities. OBJECTIVE To evaluate the most critical events in the lives of interns. PARTICIPANTS Forty-one internal medicine residents at one program participated in a two-day retreat in the fall of their first year. Each resident provided a written description of a recent high point, low point, and patient conflict. MEASUREMENTS We used a variant of grounded theory to analyze these critical incidents and determine the underlying themes of early internship. Independent inter-rater agreement of >90% was achieved for the coding of excerpts. MAIN RESULTS The 123 critical incidents were clustered into 23 categories. The categories were further organized into six themes: confidence, life balance, connections, emotional responses, managing expectations, and facilitating teamwork. High points were primarily in the themes of confidence and connections. Low points were dispersed more generally throughout the conceptual framework. Conflicts with patients were about negotiating the expectations inherent in the physician–patient relationship. CONCLUSION The high points, low points, and conflicts reported by early residents provide us with a glimpse into the lives of interns. The themes we have identified reflect critical challenges interns face the development of their professional identity. Program directors could use this process and conceptual framework to guide the development and promotion of residents’ emerging professional identities. PMID:18972091
Speed of recovery after arthroscopic rotator cuff repair.
Kurowicki, Jennifer; Berglund, Derek D; Momoh, Enesi; Disla, Shanell; Horn, Brandon; Giveans, M Russell; Levy, Jonathan C
2017-07-01
The purpose of this study was to delineate the time taken to achieve maximum improvement (plateau of recovery) and the degree of recovery observed at various time points (speed of recovery) for pain and function after arthroscopic rotator cuff repair. An institutional shoulder surgery registry query identified 627 patients who underwent arthroscopic rotator cuff repair between 2006 and 2015. Measured range of motion, patient satisfaction, and patient-reported outcome measures were analyzed for preoperative, 3-month, 6-month, 1-year, and 2-year intervals. Subgroup analysis was performed on the basis of tear size by retraction grade and number of anchors used. As an entire group, the plateau of maximum recovery for pain, function, and motion occurred at 1 year. Satisfaction with surgery was >96% at all time points. At 3 months, 74% of improvement in pain and 45% to 58% of functional improvement were realized. However, only 22% of elevation improvement was achieved (P < .001). At 6 months, 89% of improvement in pain, 81% to 88% of functional improvement, and 78% of elevation improvement were achieved (P < .001). Larger tears had a slower speed of recovery for Single Assessment Numeric Evaluation scores, forward elevation, and external rotation. Smaller tears had higher motion and functional scores across all time points. Tear size did not influence pain levels. The plateau of maximum recovery after rotator cuff repair occurred at 1 year with high satisfaction rates at all time points. At 3 months, approximately 75% of pain relief and 50% of functional recovery can be expected. Larger tears have a slower speed of recovery. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Integrating Point-of-Care Testing into a Community Emergency Department: A Mixed-Methods Evaluation.
Pines, Jesse M; Zocchi, Mark S; Carter, Caitlin; Marriott, Charles Z; Bernard, Matthew; Warner, Leah H
2018-05-13
Point-of-care testing (POCT) is a commonly used technology that hastens the time to laboratory results in emergency departments (ED). We evaluated an ED-based POCT program on ED length of stay and time to care, coupled with qualitative interviews of local ED stakeholders. We conducted a mixed-methods study (2012-16) to examine the impact of point-of-care testing in a single, community ED. The quantiative analysis involved an observational before-after study comparing time to laboratory test result (POC troponin or POC chemistry) and ED length of stay after implementation of POCT, using a propensity-weighted interrupted time series analysis (ITSA). A complementary qualitative analysis involved five semi-structured interviews with staff using grounded theory on the benefits and challenges to ED POCT. A total of 47,399 ED visits were included in the study (24,705 in pre-intervention period and 22,694 in post-intervention). After POCT implementation, overall laboratory testing increased marginally from 61 to 62%. Central laboratory troponin and chemistry declined by >50% and was replaced by POCT. Prior to POCT implementation, time to troponin and chemistry had declined steadily due to other improvements in laboratory efficiency. After POCT implementation, there was an immediate 20 minute further decline (p<0.001) in both time to troponin and time to chemistry results using the propensity-weighted comparisons. However, the declining trend observed prior to POCT implementation did not continue at the same rate post implementation. Similarly, prior to POCT implementation, ED length of stay (LOS) declined due to other quality improvements. After POCT implementation, LOS continued declined at a similar rate. Because of this prior trend, the ITSA did not show a significant decline in LOS attributable to POCT. Common benefits of POCT perceived by staff in qualitative interviews included improved quality of care (64%), and reductions in time to test results (44%). Common challenges included concerns over POCT accuracy (32%), and technical barriers (29%). In the study ED, implementation of POCT was associated with a reduction in time to test result for both troponin and chemistry. Local staff felt that faster time to test result improved quality of care; however, concerns were raised with POCT accuracy. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Jastrzębski, Zbigniew; Kiszałkiewicz, Justyna; Brzeziański, Michał; Pastuszak-Lewandoska, Dorota; Radzimińki, Łukasz; Brzeziańska-Lasota, Ewa; Jegier, Anna
2017-01-01
Recently studies have shown that, depending on the type of training and its duration, the expression levels of selected circulating myomiRNAs (c-miR-27a,b, c-miR-29a,b,c, c-miR-133a) differ and correlate with the physiological indicators of adaptation to physical activity. To analyse the expression of selected classes of miRNAs in soccer players during different periods of their training cycle. The study involved 22 soccer players aged 17-18 years. The multi-stage 20-m shuttle run test was used to estimate VO2 max among the soccer players. Samples serum were collected at baseline (time point I), after one week (time point II), and after 2 months of training (time point III). The analysis of the relative quantification (RQ) level of three exosomal myomiRNAs, c-miRNA-27b, c-miR-29a, and c-miR-133, was performed by quantitative polymerase chain reaction (qPCR) at three time points – before the training, after 1 week of training and after the completion of two months of competition season training. The expression analysis showed low expression levels (according to references) of all evaluated myomiRNAs before the training cycle. Analysis performed after a week of the training cycle and after completion of the entire training cycle showed elevated expression of all tested myomiRNAs. Statistical analysis revealed significant differences between the first and the second time point in soccer players for c-miR-27b and c-miR-29a; between the first and the third time point for c-miR-27b and c-miR-29a; and between the second and the third time point for c-miR-27b. Statistical analysis showed a positive correlation between the levels of c-miR-29a and VO2 max. Two months of training affected the expression of c-miR-27b and miR-29a in soccer players. The increased expression of c-miR-27b and c-miR-29 with training could indicate their probable role in the adaptation process that takes place in the muscular system. Possibly, the expression of c-miR-29a will be found to be involved in cardiorespiratory fitness in future research. PMID:29472735
Montenegro, Mary L L S; Braz, Carolina A; Rosa-e-Silva, Julio C; Candido-dos-Reis, Francisco J; Nogueira, Antonio A; Poli-Neto, Omero B
2015-12-01
Chronic pelvic pain is a common condition among women, and 10 to 30 % of causes originate from the abdominal wall, and are associated with trigger points. Although little is known about their pathophysiology, variable methods have been practiced clinically. The purpose of this study was to evaluate the efficacy of local anaesthetic injections versus ischemic compression via physical therapy for pain relief of abdominal wall trigger points in women with chronic pelvic pain. We conducted a parallel group randomized trial including 30 women with chronic pelvic pain with abdominal wall trigger points. Subjects were randomly assigned to one of two intervention groups. One group received an injection of 2 mL 0.5 % lidocaine without a vasoconstrictor into a trigger point. In the other group, ischemic compression via physical therapy was administered at the trigger points three times, with each session lasting for 60 s, and a rest period of 30 s between applications. Both treatments were administered during one weekly session for four weeks. Our primary outcomes were satisfactory clinical response rates and percentages of pain relief. Our secondary outcomes are pain threshold and tolerance at the trigger points. All subjects were evaluated at baseline and 1, 4, and 12 weeks after the interventions. The study was conducted at a tertiary hospital that was associated with a university providing assistance predominantly to working class women who were treated by the public health system. Clinical response rates and pain relief were significantly better at 1, 4, and 12 weeks for those receiving local anaesthetic injections than ischemic compression via physical therapy. The pain relief of women treated with local anaesthetic injections progressively improved at 1, 4, and 12 weeks after intervention. In contrast, women treated with ischemic compression did not show considerable changes in pain relief after intervention. In the local anaesthetic injection group, pain threshold and tolerance improved with time in the absence of significant differences between groups. Lidocaine injection seems to be better for reducing the severity of chronic pelvic pain secondary to abdominal wall trigger points compared to ischemic compression via physical therapy. ClinicalTrials.gov NCT00628355. Date of registration: February 25, 2008.
Shiozawa, Kazue; Watanabe, Manabu; Ikehara, Takashi; Shimizu, Ryo; Shinohara, Mie; Igarashi, Yoshinori; Sumino, Yasukiyo
2017-01-01
To determine the usefulness of arrival time parametric imaging (AtPI) using contrast-enhanced ultrasonography (CEUS) with Sonazoid in evaluating early response to sorafenib for hepatocellular carcinoma (HCC). Twenty-one advanced HCC patients with low α-fetoprotein (AFP) levels (≤35 ng/ml) who received sorafenib for at least 4 weeks were enrolled in this study. CEUS was performed before and 2 weeks after treatment, and the images of the target lesion in the arterial phase were analyzed by AtPI. In the color mapping images obtained by AtPI, the mean arrival time of the contrast agent in the target lesion from the reference point (mean time: MT) was calculated. In each patient, differences between MT before and MT 2 weeks after treatment were compared. MT (+) and MT (-) groups were defined as difference of 0 s or greater and less than 0 s, respectively. Overall survival was evaluated between the two groups. In the MT (+) (11 patients) and MT (-) (10 patients) groups, the median survival time was 792 and 403 days, respectively, which was statistically significant. The results suggested that AtPI was useful for evaluating early response to sorafenib for advanced HCC with low AFP level.
Accuracy assessment of building point clouds automatically generated from iphone images
NASA Astrophysics Data System (ADS)
Sirmacek, B.; Lindenbergh, R.
2014-06-01
Low-cost sensor generated 3D models can be useful for quick 3D urban model updating, yet the quality of the models is questionable. In this article, we evaluate the reliability of an automatic point cloud generation method using multi-view iPhone images or an iPhone video file as an input. We register such automatically generated point cloud on a TLS point cloud of the same object to discuss accuracy, advantages and limitations of the iPhone generated point clouds. For the chosen example showcase, we have classified 1.23% of the iPhone point cloud points as outliers, and calculated the mean of the point to point distances to the TLS point cloud as 0.11 m. Since a TLS point cloud might also include measurement errors and noise, we computed local noise values for the point clouds from both sources. Mean (μ) and standard deviation (σ) of roughness histograms are calculated as (μ1 = 0.44 m., σ1 = 0.071 m.) and (μ2 = 0.025 m., σ2 = 0.037 m.) for the iPhone and TLS point clouds respectively. Our experimental results indicate possible usage of the proposed automatic 3D model generation framework for 3D urban map updating, fusion and detail enhancing, quick and real-time change detection purposes. However, further insights should be obtained first on the circumstances that are needed to guarantee a successful point cloud generation from smartphone images.
Hartman, Rebecca L; Brown, Timothy L; Milavetz, Gary; Spurgin, Andrew; Gorelick, David A; Gaffney, Gary; Huestis, Marilyn A
2016-07-01
Vaporized cannabis and concurrent cannabis and alcohol intake are commonplace. We evaluated the subjective effects of cannabis, with and without alcohol, relative to blood and oral fluid (OF, advantageous for cannabis exposure screening) cannabinoid concentrations and OF/blood and OF/plasma vaporized-cannabinoid relationships. Healthy adult occasional-to-moderate cannabis smokers received a vaporized placebo or active cannabis (2.9% and 6.7% Δ(9) -tetrahydrocannabinol, THC) with or without oral low-dose alcohol (~0.065g/210L peak breath alcohol concentration [BrAC]) in a within-subjects design. Blood and OF were collected up to 8.3 h post-dose and subjective effects measured at matched time points with visual-analogue scales and 5-point Likert scales. Linear mixed models evaluated subjective effects by THC concentration, BrAC, and interactions. Effects by time point were evaluated by dose-wise analysis of variance (ANOVA). OF versus blood or plasma cannabinoid ratios and correlations were evaluated in paired-positive specimens. Nineteen participants (13 men) completed the study. Blood THC concentration or BrAC significantly associated with subjective effects including 'high', while OF contamination prevented significant OF concentration associations <1.4 h post-dose. Subjective effects persisted through 3.3-4.3 h, with alcohol potentiating the duration of the cannabis effects. Effect-versus-THC concentration and effect-versus-alcohol concentration hystereses were counterclockwise and clockwise, respectively. OF/blood and OF/plasma THC significantly correlated (all Spearman r≥0.71), but variability was high. Vaporized cannabis subjective effects were similar to those previously reported after smoking, with duration extended by concurrent alcohol. Cannabis intake was identified by OF testing, but OF concentration variability limited interpretation. Blood THC concentrations were more consistent across subjects and more accurate at predicting cannabis' subjective effects. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Priorities and prospect theory.
Happich, M; Mazurek, B
2002-01-01
Whose preferences are to be used for cost-effectiveness analysis? It has been recommended that community preferences for health states are the most appropriate ones for use in a reference case analysis. However, critics maintain that persons are not able properly to judge a health state if they have not experienced the condition themselves. This problem is analyzed here in the framework of Prospect Theory. It can be argued that the differing reference points of patients and the general public are responsible for deviating results. In addition, we argue that risk attitudes with respect to health-related quality of life are an indicator of reference points. If patients and the general public refer to the same reference point, i.e., they have the same risk attitude, the hypothesis is that deviations no longer significantly differ. Evaluations of the health condition of tinnitus by 210 patients and 210 unaffected persons were compared. The Time Tradeoff and Standard Gamble methods were applied to elicit preferences. Risk attitude was measured with the question of whether participants would undergo a treatment that could either improve or worsen their health condition, both with an equal chance (five possible answers between "in no case" and "in any case"). Affected persons indicated significantly higher values for tinnitus-related quality of life according to the Standard Gamble method. The difference between Time Tradeoff values was less dramatic but still significant. In addition, nonaffected persons are more risk-averse than affected persons. However, differences in evaluations are not significant considering single risk groups (e.g., those who answered "in no case"). Prospect Theory is a reasonable framework for considering the question of whose preferences count. If this result can be generalized for other diseases as well, it allows the mathematical combination of "objective" evaluations by the general public with the illness experience of patients. These evaluations should be weighted with patients' risk attitudes, i.e., community preferences can be used if they are corrected for risk attitudes.
Li, Bingyi; Chen, Liang; Wei, Chunpeng; Xie, Yizhuang; Chen, He; Yu, Wenyue
2017-01-01
With the development of satellite load technology and very large scale integrated (VLSI) circuit technology, onboard real-time synthetic aperture radar (SAR) imaging systems have become a solution for allowing rapid response to disasters. A key goal of the onboard SAR imaging system design is to achieve high real-time processing performance with severe size, weight, and power consumption constraints. In this paper, we analyse the computational burden of the commonly used chirp scaling (CS) SAR imaging algorithm. To reduce the system hardware cost, we propose a partial fixed-point processing scheme. The fast Fourier transform (FFT), which is the most computation-sensitive operation in the CS algorithm, is processed with fixed-point, while other operations are processed with single precision floating-point. With the proposed fixed-point processing error propagation model, the fixed-point processing word length is determined. The fidelity and accuracy relative to conventional ground-based software processors is verified by evaluating both the point target imaging quality and the actual scene imaging quality. As a proof of concept, a field- programmable gate array—application-specific integrated circuit (FPGA-ASIC) hybrid heterogeneous parallel accelerating architecture is designed and realized. The customized fixed-point FFT is implemented using the 130 nm complementary metal oxide semiconductor (CMOS) technology as a co-processor of the Xilinx xc6vlx760t FPGA. A single processing board requires 12 s and consumes 21 W to focus a 50-km swath width, 5-m resolution stripmap SAR raw data with a granularity of 16,384 × 16,384. PMID:28672813
Yang, Chen; Li, Bingyi; Chen, Liang; Wei, Chunpeng; Xie, Yizhuang; Chen, He; Yu, Wenyue
2017-06-24
With the development of satellite load technology and very large scale integrated (VLSI) circuit technology, onboard real-time synthetic aperture radar (SAR) imaging systems have become a solution for allowing rapid response to disasters. A key goal of the onboard SAR imaging system design is to achieve high real-time processing performance with severe size, weight, and power consumption constraints. In this paper, we analyse the computational burden of the commonly used chirp scaling (CS) SAR imaging algorithm. To reduce the system hardware cost, we propose a partial fixed-point processing scheme. The fast Fourier transform (FFT), which is the most computation-sensitive operation in the CS algorithm, is processed with fixed-point, while other operations are processed with single precision floating-point. With the proposed fixed-point processing error propagation model, the fixed-point processing word length is determined. The fidelity and accuracy relative to conventional ground-based software processors is verified by evaluating both the point target imaging quality and the actual scene imaging quality. As a proof of concept, a field- programmable gate array-application-specific integrated circuit (FPGA-ASIC) hybrid heterogeneous parallel accelerating architecture is designed and realized. The customized fixed-point FFT is implemented using the 130 nm complementary metal oxide semiconductor (CMOS) technology as a co-processor of the Xilinx xc6vlx760t FPGA. A single processing board requires 12 s and consumes 21 W to focus a 50-km swath width, 5-m resolution stripmap SAR raw data with a granularity of 16,384 × 16,384.
NASA Astrophysics Data System (ADS)
Ueno, Tetsuro; Hino, Hideitsu; Hashimoto, Ai; Takeichi, Yasuo; Sawada, Masahiro; Ono, Kanta
2018-01-01
Spectroscopy is a widely used experimental technique, and enhancing its efficiency can have a strong impact on materials research. We propose an adaptive design for spectroscopy experiments that uses a machine learning technique to improve efficiency. We examined X-ray magnetic circular dichroism (XMCD) spectroscopy for the applicability of a machine learning technique to spectroscopy. An XMCD spectrum was predicted by Gaussian process modelling with learning of an experimental spectrum using a limited number of observed data points. Adaptive sampling of data points with maximum variance of the predicted spectrum successfully reduced the total data points for the evaluation of magnetic moments while providing the required accuracy. The present method reduces the time and cost for XMCD spectroscopy and has potential applicability to various spectroscopies.
NASA Astrophysics Data System (ADS)
Koike, Katsuaki; Mori, Kazuya; Yamao, Toshitaka; Fujimi, Toshio
As an activity of one working group for the Good Practice at Kumamoto Univ., we proposed a questionnaire survey on understanding degree of the uppermost important points of each class in addition to the usual class-evaluation questionnaire. Each class lists three uppermost important points which are essential to understand the class contents. The understanding degree is classified into four levels ; full, most, insufficient, and not at all understandings. By analyzing the replies to 124 classes in the 2008 school year with a regression model, the understanding degrees of the bachelor students of the faculty of engineering were clarified to be affected meaningfully by degree of difficulty, effectiveness of audiovisual aids, self-study time, and attendance to class.
2013-01-01
Background Mobile technology offers the potential to deliver health-related interventions to individuals who would not otherwise present for in-person treatment. Text messaging (short message service, SMS), being the most ubiquitous form of mobile communication, is a promising method for reaching the most individuals. Objective The goal of the present study was to evaluate the feasibility and preliminary efficacy of a smoking cessation intervention program delivered through text messaging. Methods Adult participants (N=60, age range 18-52 years) took part in a single individual smoking cessation counseling session, and were then randomly assigned to receive either daily non-smoking related text messages (control condition) or the TXT-2-Quit (TXT) intervention. TXT consisted of automated smoking cessation messages tailored to individual’s stage of smoking cessation, specialized messages provided on-demand based on user requests for additional support, and a peer-to-peer social support network. Generalized estimating equation analysis was used to assess the primary outcome (7-day point-prevalence abstinence) using a 2 (treatment groups)×3 (time points) repeated measures design across three time points: 8 weeks, 3 months, and 6 months. Results Smoking cessation results showed an overall significant group difference in 7-day point prevalence abstinence across all follow-up time points. Individuals given the TXT intervention, with higher odds of 7-day point prevalence abstinence for the TXT group compared to the Mojo group (OR=4.52, 95% CI=1.24, 16.53). However, individual comparisons at each time point did not show significant between-group differences, likely due to reduced statistical power. Intervention feasibility was greatly improved by switching from traditional face-to-face recruitment methods (4.7% yield) to an online/remote strategy (41.7% yield). Conclusions Although this study was designed to develop and provide initial testing of the TXT-2-Quit system, these initial findings provide promising evidence that a text-based intervention can be successfully implemented with a diverse group of adult smokers. Trial Registration ClinicalTrials.gov: NCT01166464; http://clinicaltrials.gov/ct2/show/NCT01166464 (Archived by WebCite at http://www.webcitation.org/6IOE8XdE0). PMID:25098502
Hernandez, Stephen C; Sibley, Haley; Fink, Daniel S; Kunduk, Melda; Schexnaildre, Mell; Kakade, Anagha; McWhorter, Andrew J
2016-05-01
Micronized acellular dermis has been used for nearly 15 years to correct glottic insufficiency. With previous demonstration of safety and efficacy, this study aims to evaluate intermediate and long-term voice outcomes in those who underwent injection laryngoplasty for unilateral vocal fold paralysis. Technique and timing of injection were also reviewed to assess their impact on outcomes. Case series with chart review. Tertiary care center. Patients undergoing injection laryngoplasty from May 2007 to September 2012 were reviewed for possible inclusion. Pre- and postoperative Voice Handicap Index (VHI) scores, as well as senior speech-language pathologists' blinded assessment of voice, were collected for analysis. The final sample included patients who underwent injection laryngoplasty for unilateral vocal fold paralysis, 33 of whom had VHI results and 37 of whom had voice recordings. Additional data were obtained, including technique and timing of injection. Analysis was performed on those patients above with VHI and perceptual voice grades before and at least 6 months following injection. Mean VHI improved by 28.7 points at 6 to 12 months and 22.8 points at >12 months (P = .001). Mean perceptual voice grades improved by 17.6 points at 6 to 12 months and 16.3 points at >12 months (P < .001). No statistically significant difference was found with technique or time to injection. Micronized acellular dermis is a safe injectable that improved both patient-completed voice ratings and blinded reviewer voice gradings at intermediate and long-term follow-up. Further investigation may be warranted regarding technique and timing of injection. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.
NASA Astrophysics Data System (ADS)
Miga, Michael I.; Weis, Jared A.; Granero-Molto, Froilan; Spagnoli, Anna
2010-03-01
Understanding bone remodeling and mechanical property characteristics is important for assessing treatments to accelerate healing or in developing diagnostics to evaluate successful return to function. The murine system whereby mid-diaphaseal tibia fractures are imparted on the subject and fracture healing is assessed at different time points and under different therapeutic conditions is a particularly useful model to study. In this work, a novel inverse geometric nonlinear elasticity modeling framework is proposed that can reconstruct multiple mechanical properties from uniaxial testing data. To test this framework, the Lame' constants were reconstructed within the context of a murine cohort (n=6) where there were no differences in treatment post tibia fracture except that half of the mice were allowed to heal 4 days longer (10 day, and 14 day healing time point, respectively). The properties reconstructed were a shear modulus of G=511.2 +/- 295.6 kPa, and 833.3+/- 352.3 kPa for the 10 day, and 14 day time points respectively. The second Lame' constant reconstructed at λ=1002.9 +/-42.9 kPa, and 14893.7 +/- 863.3 kPa for the 10 day, and 14 day time points respectively. An unpaired Student t-test was used to test for statistically significant differences among the groups. While the shear modulus did not meet our criteria for significance, the second Lame' constant did at a value p<0.0001. Traditional metrics that are commonly used within the bone fracture healing research community were not found to be statistically significant.
NASA Astrophysics Data System (ADS)
Klapa, Przemyslaw; Mitka, Bartosz; Zygmunt, Mariusz
2017-12-01
Capability of obtaining a multimillion point cloud in a very short time has made the Terrestrial Laser Scanning (TLS) a widely used tool in many fields of science and technology. The TLS accuracy matches traditional devices used in land surveying (tacheometry, GNSS - RTK), but like any measurement it is burdened with error which affects the precise identification of objects based on their image in the form of a point cloud. The point’s coordinates are determined indirectly by means of measuring the angles and calculating the time of travel of the electromagnetic wave. Each such component has a measurement error which is translated into the final result. The XYZ coordinates of a measuring point are determined with some uncertainty and the very accuracy of determining these coordinates is reduced as the distance to the instrument increases. The paper presents the results of examination of geometrical stability of a point cloud obtained by means terrestrial laser scanner and accuracy evaluation of solids determined using the cloud. Leica P40 scanner and two different settings of measuring points were used in the tests. The first concept involved placing a few balls in the field and then scanning them from various sides at similar distances. The second part of measurement involved placing balls and scanning them a few times from one side but at varying distances from the instrument to the object. Each measurement encompassed a scan of the object with automatic determination of its position and geometry. The desk studies involved a semiautomatic fitting of solids and measurement of their geometrical elements, and comparison of parameters that determine their geometry and location in space. The differences of measures of geometrical elements of balls and translations vectors of the solids centres indicate the geometrical changes of the point cloud depending on the scanning distance and parameters. The results indicate the changes in the geometry of scanned objects depending on the point cloud quality and distance from the measuring instrument. Varying geometrical dimensions of the same element suggest also that the point cloud does not keep a stable geometry of measured objects.
Cundy, Thomas P; Rowland, Simon P; Gattas, Nicholas E; White, Alan D; Najmaldin, Azad S
2015-06-01
Fundoplication is a leading application of robotic surgery in children, yet the learning curve for this procedure (RF) remains ill-defined. This study aims to identify various learning curve transition points, using cumulative summation (CUSUM) analysis. A prospective database was examined to identify RF cases undertaken during 2006-2014. Time-based surgical process outcomes were evaluated, as well as clinical outcomes. A total of 57 RF cases were included. Statistically significant transitions beyond the learning phase were observed at cases 42, 34 and 37 for docking, console and total operating room times, respectively. A steep early learning phase for docking time was overcome after 12 cases. There were three Clavien-Dindo grade ≥ 3 complications, with two patients requiring redo fundoplication. We identified numerous well-defined learning curve trends to affirm that experience confers significant temporal improvements. Our findings highlight the value of the CUSUM method for learning curve evaluation. Copyright © 2014 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hou, Z; Terry, N; Hubbard, S S
2013-02-12
In this study, we evaluate the possibility of monitoring soil moisture variation using tomographic ground penetrating radar travel time data through Bayesian inversion, which is integrated with entropy memory function and pilot point concepts, as well as efficient sampling approaches. It is critical to accurately estimate soil moisture content and variations in vadose zone studies. Many studies have illustrated the promise and value of GPR tomographic data for estimating soil moisture and associated changes, however, challenges still exist in the inversion of GPR tomographic data in a manner that quantifies input and predictive uncertainty, incorporates multiple data types, handles non-uniquenessmore » and nonlinearity, and honors time-lapse tomograms collected in a series. To address these challenges, we develop a minimum relative entropy (MRE)-Bayesian based inverse modeling framework that non-subjectively defines prior probabilities, incorporates information from multiple sources, and quantifies uncertainty. The framework enables us to estimate dielectric permittivity at pilot point locations distributed within the tomogram, as well as the spatial correlation range. In the inversion framework, MRE is first used to derive prior probability distribution functions (pdfs) of dielectric permittivity based on prior information obtained from a straight-ray GPR inversion. The probability distributions are then sampled using a Quasi-Monte Carlo (QMC) approach, and the sample sets provide inputs to a sequential Gaussian simulation (SGSim) algorithm that constructs a highly resolved permittivity/velocity field for evaluation with a curved-ray GPR forward model. The likelihood functions are computed as a function of misfits, and posterior pdfs are constructed using a Gaussian kernel. Inversion of subsequent time-lapse datasets combines the Bayesian estimates from the previous inversion (as a memory function) with new data. The memory function and pilot point design takes advantage of the spatial-temporal correlation of the state variables. We first apply the inversion framework to a static synthetic example and then to a time-lapse GPR tomographic dataset collected during a dynamic experiment conducted at the Hanford Site in Richland, WA. We demonstrate that the MRE-Bayesian inversion enables us to merge various data types, quantify uncertainty, evaluate nonlinear models, and produce more detailed and better resolved estimates than straight-ray based inversion; therefore, it has the potential to improve estimates of inter-wellbore dielectric permittivity and soil moisture content and to monitor their temporal dynamics more accurately.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hou, Zhangshuan; Terry, Neil C.; Hubbard, Susan S.
2013-02-22
In this study, we evaluate the possibility of monitoring soil moisture variation using tomographic ground penetrating radar travel time data through Bayesian inversion, which is integrated with entropy memory function and pilot point concepts, as well as efficient sampling approaches. It is critical to accurately estimate soil moisture content and variations in vadose zone studies. Many studies have illustrated the promise and value of GPR tomographic data for estimating soil moisture and associated changes, however, challenges still exist in the inversion of GPR tomographic data in a manner that quantifies input and predictive uncertainty, incorporates multiple data types, handles non-uniquenessmore » and nonlinearity, and honors time-lapse tomograms collected in a series. To address these challenges, we develop a minimum relative entropy (MRE)-Bayesian based inverse modeling framework that non-subjectively defines prior probabilities, incorporates information from multiple sources, and quantifies uncertainty. The framework enables us to estimate dielectric permittivity at pilot point locations distributed within the tomogram, as well as the spatial correlation range. In the inversion framework, MRE is first used to derive prior probability density functions (pdfs) of dielectric permittivity based on prior information obtained from a straight-ray GPR inversion. The probability distributions are then sampled using a Quasi-Monte Carlo (QMC) approach, and the sample sets provide inputs to a sequential Gaussian simulation (SGSIM) algorithm that constructs a highly resolved permittivity/velocity field for evaluation with a curved-ray GPR forward model. The likelihood functions are computed as a function of misfits, and posterior pdfs are constructed using a Gaussian kernel. Inversion of subsequent time-lapse datasets combines the Bayesian estimates from the previous inversion (as a memory function) with new data. The memory function and pilot point design takes advantage of the spatial-temporal correlation of the state variables. We first apply the inversion framework to a static synthetic example and then to a time-lapse GPR tomographic dataset collected during a dynamic experiment conducted at the Hanford Site in Richland, WA. We demonstrate that the MRE-Bayesian inversion enables us to merge various data types, quantify uncertainty, evaluate nonlinear models, and produce more detailed and better resolved estimates than straight-ray based inversion; therefore, it has the potential to improve estimates of inter-wellbore dielectric permittivity and soil moisture content and to monitor their temporal dynamics more accurately.« less
Polat, Metin; Korkmaz Eryılmaz, Selcen; Aydoğan, Sami
2018-01-01
In order to ensure that athletes achieve their highest performance levels during competitive seasons, monitoring their long-term performance data is crucial for understanding the impact of ongoing training programs and evaluating training strategies. The present study was thus designed to investigate the variations in body composition, maximal oxygen uptake (VO 2max ), and gas exchange threshold values of cross-country skiers across training phases throughout a season. In total, 15 athletes who participate in international cross-country ski competitions voluntarily took part in this study. The athletes underwent incremental treadmill running tests at 3 different time points over a period of 1 year. The first measurements were obtained in July, during the first preparation period; the second measurements were obtained in October, during the second preparation period; and the third measurements were obtained in February, during the competition period. Body weight, body mass index (BMI), body fat (%), as well as VO 2max values and gas exchange threshold, measured using V-slope method during the incremental running tests, were assessed at all 3 time points. The collected data were analyzed using SPSS 20 package software. Significant differences between the measurements were assessed using Friedman's twoway variance analysis with a post hoc option. The athletes' body weights and BMI measurements at the third point were significantly lower compared with the results of the second measurement ( p <0.001). Moreover, the incremental running test time was significantly higher at the third measurement, compared with both the first ( p <0.05) and the second ( p <0.01) measurements. Similarly, the running speed during the test was significantly higher at the third measurement time point compared with the first measurement time point ( p <0.05). Body fat (%), time to reach the gas exchange threshold, running speed at the gas exchange threshold, VO 2max , amount of oxygen consumed at gas exchange threshold level (VO 2GET ), maximal heart rate (HR max ), and heart rate at gas exchange threshold level (HR GET ) values did not significantly differ between the measurement time points ( p >0.05). VO 2max and gas exchange threshold values recorded during the third measurements, the timing of which coincided with the competitive season of the cross-country skiers, did not significantly change, but their incremental running test time and running speed significantly increased while their body weight and BMI significantly decreased. These results indicate that the cross-country skiers developed a tolerance for high-intensity exercise and reached their highest level of athletic performance during the competitive season.
NASA Astrophysics Data System (ADS)
Nakazono, Shogo; Kobori, Satoshi
The button-press task means that the subject observes a moving target and presses a button to stop it when the target enters a specified area on a computer display. Subjects perform normal task, suppressed task and delayed task. In the suppressed task, the moving target disappears at some point during the trial. In the delayed task, there is some lag time between the time of pressing button and of stopping target. In these tasks, subjects estimate the movement of the target, and press the button considering his/her own reaction time. In our previous study, we showed that cognitive and motor function was able to be evaluated by these tasks. In this study, we examined error data of children with developmental disabilities to evaluate the cognitive function, and investigated the learning processes. Moreover, we discussed the developmental stages by comparing the children with disabilities to normal control children, and we clarified the behavior characteristics of children with developmental disabilities. Asa result, it was shown that our evaluation method and system for the button-press task were effective to evaluate cognitive ability of children with developmental disabilities.
Covic, Tanya; Pallant, Julie F; Conaghan, Philip G; Tennant, Alan
2007-01-01
Background The aim of this study was to test the internal validity of the total Center for Epidemiologic Studies-Depression (CES-D) scale using Rasch analysis in a rheumatoid arthritis (RA) population. Methods CES-D was administered to 157 patients with RA over three time points within a 12 month period. Rasch analysis was applied using RUMM2020 software to assess the overall fit of the model, the response scale used, individual item fit, differential item functioning (DIF) and person separation. Results Pooled data across three time points was shown to fit the Rasch model with removal of seven items from the original 20-item CES-D scale. It was necessary to rescore the response format from four to three categories in order to improve the scale's fit. Two items demonstrated some DIF for age and gender but were retained within the 13-item CES-D scale. A new cut point for depression score of 9 was found to correspond to the original cut point score of 16 in the full CES-D scale. Conclusion This Rasch analysis of the CES-D in a longstanding RA cohort resulted in the construction of a modified 13-item scale with good internal validity. Further validation of the modified scale is recommended particularly in relation to the new cut point for depression. PMID:17629902
Riese, Alison; Rappaport, Leah; Alverson, Brian; Park, Sangshin; Rockney, Randal M
2017-06-01
Clinical performance evaluations are major components of medical school clerkship grades. But are they sufficiently objective? This study aimed to determine whether student and evaluator gender is associated with assessment of overall clinical performance. This was a retrospective analysis of 4,272 core clerkship clinical performance evaluations by 829 evaluators of 155 third-year students, within the Alpert Medical School grading database for the 2013-2014 academic year. Overall clinical performance, assessed on a three-point scale (meets expectations, above expectations, exceptional), was extracted from each evaluation, as well as evaluator gender, age, training level, department, student gender and age, and length of observation time. Hierarchical ordinal regression modeling was conducted to account for clustering of evaluations. Female students were more likely to receive a better grade than males (adjusted odds ratio [AOR] 1.30, 95% confidence interval [CI] 1.13-1.50), and female evaluators awarded lower grades than males (AOR 0.72, 95% CI 0.55-0.93), adjusting for department, observation time, and student and evaluator age. The interaction between student and evaluator gender was significant (P = .03), with female evaluators assigning higher grades to female students, while male evaluators' grading did not differ by student gender. Students who spent a short time with evaluators were also more likely to get a lower grade. A one-year examination of all third-year clerkship clinical performance evaluations at a single institution revealed that male and female evaluators rated male and female students differently, even when accounting for other measured variables.
Compression performance comparison in low delay real-time video for mobile applications
NASA Astrophysics Data System (ADS)
Bivolarski, Lazar
2012-10-01
This article compares the performance of several current video coding standards in the conditions of low-delay real-time in a resource constrained environment. The comparison is performed using the same content and the metrics and mix of objective and perceptual quality metrics. The metrics results in different coding schemes are analyzed from a point of view of user perception and quality of service. Multiple standards are compared MPEG-2, MPEG4 and MPEG-AVC and well and H.263. The metrics used in the comparison include SSIM, VQM and DVQ. Subjective evaluation and quality of service are discussed from a point of view of perceptual metrics and their incorporation in the coding scheme development process. The performance and the correlation of results are presented as a predictor of the performance of video compression schemes.
Plasma serotonin in horses undergoing surgery for small intestinal colic
Torfs, Sara C.; Maes, An A.; Delesalle, Catherine J.; Pardon, Bart; Croubels, Siska M.; Deprez, Piet
2015-01-01
This study compared serotonin concentrations in platelet poor plasma (PPP) from healthy horses and horses with surgical small intestinal (SI) colic, and evaluated their association with postoperative ileus, strangulation and non-survival. Plasma samples (with EDTA) from 33 horses with surgical SI colic were collected at several pre- and post-operative time points. Serotonin concentrations were determined using liquid-chromatography tandem mass spectrometry. Results were compared with those for 24 healthy control animals. The serotonin concentrations in PPP were significantly lower (P < 0.01) in pre- and post-operative samples from surgical SI colic horses compared to controls. However, no association with postoperative ileus or non-survival could be demonstrated at any time point. In this clinical study, plasma serotonin was not a suitable prognostic factor in horses with SI surgical colic. PMID:25694668
Pose estimation and tracking of non-cooperative rocket bodies using Time-of-Flight cameras
NASA Astrophysics Data System (ADS)
Gómez Martínez, Harvey; Giorgi, Gabriele; Eissfeller, Bernd
2017-10-01
This paper presents a methodology for estimating the position and orientation of a rocket body in orbit - the target - undergoing a roto-translational motion, with respect to a chaser spacecraft, whose task is to match the target dynamics for a safe rendezvous. During the rendezvous maneuver the chaser employs a Time-of-Flight camera that acquires a point cloud of 3D coordinates mapping the sensed target surface. Once the system identifies the target, it initializes the chaser-to-target relative position and orientation. After initialization, a tracking procedure enables the system to sense the evolution of the target's pose between frames. The proposed algorithm is evaluated using simulated point clouds, generated with a CAD model of the Cosmos-3M upper stage and the PMD CamCube 3.0 camera specifications.
Basu-Roy, Somapriya; Kar, Sanjay Kumar; Das, Sounik; Lahiri, Annesha
2017-01-01
Purpose This study is intended to compare dose-volume parameters evaluated using different forward planning- optimization techniques, involving two applicator systems in intracavitary brachytherapy for cervical cancer. It looks for the best applicator-optimization combination to fulfill recommended dose-volume objectives in different high-dose-rate (HDR) fractionation schedules. Material and methods We used tandem-ring and Fletcher-style tandem-ovoid applicator in same patients in two fractions of brachytherapy. Six plans were generated for each patient utilizing 3 forward optimization techniques for each applicator used: equal dwell weight/times (‘no optimization’), ‘manual dwell weight/times’, and ‘graphical’. Plans were normalized to left point A and dose of 8 Gy was prescribed. Dose volume and dose point parameters were compared. Results Without graphical optimization, maximum width and thickness of volume enclosed by 100% isodose line, dose to 90%, and 100% of clinical target volume (CTV); minimum, maximum, median, and average dose to both rectum and bladder are significantly higher with Fletcher applicator. Even if it is done, dose to both points B, minimum dose to CTV, and treatment time; dose to 2 cc (D2cc) rectum and rectal point etc.; D2cc, minimum, maximum, median, and average dose to sigmoid colon; D2cc of bladder remain significantly higher with this applicator. Dose to bladder point is similar (p > 0.05) between two applicators, after all optimization techniques. Conclusions Fletcher applicator generates higher dose to both CTV and organs at risk (2 cc volumes) after all optimization techniques. Dose restriction to rectum is possible using graphical optimization only during selected HDR fractionation schedules. Bladder always receives dose higher than recommended, and 2 cc sigmoid colon always gets permissible dose. Contrarily, graphical optimization with ring applicators fulfills all dose volume objectives in all HDR fractionations practiced. PMID:29204164
Mutzner, Lena; Staufer, Philipp; Ort, Christoph
2016-11-01
Wet-weather discharges contribute to anthropogenic micropollutant loads entering the aquatic environment. Thousands of wet-weather discharges exist in Swiss sewer systems, and we do not have the capacity to monitor them all. We consequently propose a model-based approach designed to identify critical discharge points in order to support effective monitoring. We applied a dynamic substance flow model to four substances representing different entry routes: indoor (Triclosan, Mecoprop, Copper) as well as rainfall-mobilized (Glyphosate, Mecoprop, Copper) inputs. The accumulation on different urban land-use surfaces in dry weather and subsequent substance-specific wash-off is taken into account. For evaluation, we use a conservative screening approach to detect critical discharge points. This approach considers only local dilution generated onsite from natural, unpolluted areas, i.e. excluding upstream dilution. Despite our conservative assumptions, we find that the environmental quality standards for Glyphosate and Mecoprop are not exceeded during any 10-min time interval over a representative one-year simulation period for all 2500 Swiss municipalities. In contrast, the environmental quality standard is exceeded during at least 20% of the discharge time at 83% of all modelled discharge points for Copper and at 71% for Triclosan. For Copper, this corresponds to a total median duration of approximately 19 days per year. For Triclosan, discharged only via combined sewer overflows, this means a median duration of approximately 10 days per year. In general, stormwater outlets contribute more to the calculated effect than combined sewer overflows for rainfall-mobilized substances. We further evaluate the Urban Index (A urban,impervious /A natural ) as a proxy for critical discharge points: catchments where Triclosan and Copper exceed the corresponding environmental quality standard often have an Urban Index >0.03. A dynamic substance flow analysis allows us to identify the most critical discharge points to be prioritized for more detailed analyses and monitoring. This forms a basis for the efficient mitigation of pollution. Copyright © 2016 Elsevier Ltd. All rights reserved.
Modifications in SIFT-based 3D reconstruction from image sequence
NASA Astrophysics Data System (ADS)
Wei, Zhenzhong; Ding, Boshen; Wang, Wei
2014-11-01
In this paper, we aim to reconstruct 3D points of the scene from related images. Scale Invariant Feature Transform( SIFT) as a feature extraction and matching algorithm has been proposed and improved for years and has been widely used in image alignment and stitching, image recognition and 3D reconstruction. Because of the robustness and reliability of the SIFT's feature extracting and matching algorithm, we use it to find correspondences between images. Hence, we describe a SIFT-based method to reconstruct 3D sparse points from ordered images. In the process of matching, we make a modification in the process of finding the correct correspondences, and obtain a satisfying matching result. By rejecting the "questioned" points before initial matching could make the final matching more reliable. Given SIFT's attribute of being invariant to the image scale, rotation, and variable changes in environment, we propose a way to delete the multiple reconstructed points occurred in sequential reconstruction procedure, which improves the accuracy of the reconstruction. By removing the duplicated points, we avoid the possible collapsed situation caused by the inexactly initialization or the error accumulation. The limitation of some cases that all reprojected points are visible at all times also does not exist in our situation. "The small precision" could make a big change when the number of images increases. The paper shows the contrast between the modified algorithm and not. Moreover, we present an approach to evaluate the reconstruction by comparing the reconstructed angle and length ratio with actual value by using a calibration target in the scene. The proposed evaluation method is easy to be carried out and with a great applicable value. Even without the Internet image datasets, we could evaluate our own results. In this paper, the whole algorithm has been tested on several image sequences both on the internet and in our shots.
Huang, Jihan; Li, Mengying; Lv, Yinghua; Yang, Juan; Xu, Ling; Wang, Jingjing; Chen, Junchao; Wang, Kun; He, Yingchun; Zheng, Qingshan
2016-09-01
This study was aimed at exploring the accuracy of population pharmacokinetic method in evaluating the bioequivalence of pidotimod with sparse data profiles and whether this method is suitable for bioequivalence evaluation in special populations such as children with fewer samplings. Methods In this single-dose, two-period crossover study, 20 healthy male Chinese volunteers were randomized 1 : 1 to receive either the test or reference formulation, with a 1-week washout before receiving the alternative formulation. Noncompartmental and population compartmental pharmacokinetic analyses were conducted. Simulated data were analyzed to graphically evaluate the model and the pharmacokinetic characteristics of the two pidotimod formulations. Various sparse sampling scenarios were generated from the real bioequivalence clinical trial data and evaluated by population pharmacokinetic method. The 90% confidence intervals (CIs) for AUC0-12h, AUC0-∞, and Cmax were 97.3 - 118.7%, 96.9 - 118.7%, and 95.1 - 109.8%, respectively, within the 80 - 125% range for bioequivalence using noncompartmental analysis. The population compartmental pharmacokinetics of pidotimod were described using a one-compartment model with first-order absorption and lag time. In the comparison of estimations in different dataset, the estimation of random three- and< fixed four-point sampling strategies can provide results similar to those obtained through rich sampling. The nonlinear mixed-effects model requires fewer data points. Moreover, compared with the noncompartmental analysis method, the pharmacokinetic parameters can be more accurately estimated using nonlinear mixed-effects model. The population pharmacokinetic modeling method was used to assess the bioequivalence of two pidotimod formulations with relatively few sampling points and further validated the bioequivalence of the two formulations. This method may provide useful information for regulating bioequivalence evaluation in special populations.
Rodgers, Helen; Shaw, Lisa; Bosomworth, Helen; Aird, Lydia; Alvarado, Natasha; Andole, Sreeman; Cohen, David L; Dawson, Jesse; Eyre, Janet; Finch, Tracy; Ford, Gary A; Hislop, Jennifer; Hogg, Steven; Howel, Denise; Hughes, Niall; Krebs, Hermano Igo; Price, Christopher; Rochester, Lynn; Stamp, Elaine; Ternent, Laura; Turner, Duncan; Vale, Luke; Warburton, Elizabeth; van Wijck, Frederike; Wilkes, Scott
2017-07-20
Loss of arm function is a common and distressing consequence of stroke. We describe the protocol for a pragmatic, multicentre randomised controlled trial to determine whether robot-assisted training improves upper limb function following stroke. Study design: a pragmatic, three-arm, multicentre randomised controlled trial, economic analysis and process evaluation. NHS stroke services. adults with acute or chronic first-ever stroke (1 week to 5 years post stroke) causing moderate to severe upper limb functional limitation. Randomisation groups: 1. Robot-assisted training using the InMotion robotic gym system for 45 min, three times/week for 12 weeks 2. Enhanced upper limb therapy for 45 min, three times/week for 12 weeks 3. Usual NHS care in accordance with local clinical practice Randomisation: individual participant randomisation stratified by centre, time since stroke, and severity of upper limb impairment. upper limb function measured by the Action Research Arm Test (ARAT) at 3 months post randomisation. upper limb impairment (Fugl-Meyer Test), activities of daily living (Barthel ADL Index), quality of life (Stroke Impact Scale, EQ-5D-5L), resource use, cost per quality-adjusted life year and adverse events, at 3 and 6 months. Blinding: outcomes are undertaken by blinded assessors. Economic analysis: micro-costing and economic evaluation of interventions compared to usual NHS care. A within-trial analysis, with an economic model will be used to extrapolate longer-term costs and outcomes. Process evaluation: semi-structured interviews with participants and professionals to seek their views and experiences of the rehabilitation that they have received or provided, and factors affecting the implementation of the trial. allowing for 10% attrition, 720 participants provide 80% power to detect a 15% difference in successful outcome between each of the treatment pairs. Successful outcome definition: baseline ARAT 0-7 must improve by 3 or more points; baseline ARAT 8-13 improve by 4 or more points; baseline ARAT 14-19 improve by 5 or more points; baseline ARAT 20-39 improve by 6 or more points. The results from this trial will determine whether robot-assisted training improves upper limb function post stroke. ISRCTN, identifier: ISRCTN69371850 . Registered 4 October 2013.