Devesa, V; Rovesti, G L; Urrutia, P G; Sanroman, F; Rodriguez-Quiros, J
2015-06-01
The objective of this study was to evaluate technical feasibility and efficacy of a joint distraction technique by traction stirrup to facilitate shoulder arthroscopy and assess potential soft tissue damage. Twenty shoulders were evaluated radiographically before distraction. Distraction was applied with loads from 40 N up to 200 N, in 40 N increments, and the joint space was recorded at each step by radiographic images. The effects of joint flexion and intra-articular air injection at maximum load were evaluated. Radiographic evaluation was performed after distraction to evaluate ensuing joint laxity. Joint distraction by traction stirrup technique produces a significant increase in the joint space; an increase in joint laxity could not be inferred by standard and stress radiographs. However, further clinical studies are required to evaluate potential neurovascular complications. A wider joint space may be useful to facilitate arthroscopy, reducing the likelihood for iatrogenic damage to intra-articular structures. Copyright © 2015 Elsevier Ltd. All rights reserved.
Product evaluation : Ruscoe 983 joint sealant
DOT National Transportation Integrated Search
1986-07-10
This report contains a product evaluation of Ruscoe's 983 joint sealant. Ruscoe 983 is an asphalt base single compound joint sealant. It contains an aluminum fortified adhesive and is designed for use on highway expansion joints, bridge joints, and r...
A field evaluation of Transflex bridge joint performance.
DOT National Transportation Integrated Search
1972-01-01
Presented are the results of a field evaluation of the various types of the General Tire Transflex joint known to be in use in Virginia. An effort was made, whenever possible, to qualitatively evaluate the joints with respect to their (1) watertightn...
Evaluation of narrow transverse contraction joints in jointed plain concrete pavements.
DOT National Transportation Integrated Search
2006-03-01
This report presents the results of a research project conducted at the Louisiana Transportation Research Center (LTRC) to evaluate the performance of narrow transverse contraction joints to control cracking in jointed plain concrete pavements. In ad...
Dissimilar metals joint evaluation
NASA Technical Reports Server (NTRS)
Wakefield, M. E.; Apodaca, L. E.
1974-01-01
Dissimilar metals tubular joints between 2219-T851 aluminum alloy and 304L stainless steel were fabricated and tested to evaluate bonding processes. Joints were fabricated by four processes: (1) inertia (friction) weldings, where the metals are spun and forced together to create the weld; (2) explosive welding, where the metals are impacted together at high velocity; (3) co-extrusion, where the metals are extruded in contact at high temperature to promote diffusion; and (4) swaging, where residual stresses in the metals after a stretching operation maintain forced contact in mutual shear areas. Fifteen joints of each type were prepared and evaluated in a 6.35 cm (2.50 in.) O.D. size, with 0.32 cm (0.13 in.) wall thickness, and 7.6 cm (3.0 in) total length. The joints were tested to evaluate their ability to withstand pressure cycle, thermal cycle, galvanic corrosion and burst tests. Leakage tests and other non-destructive test techniques were used to evaluate the behavior of the joints, and the microstructure of the bond areas was analyzed.
Gyrd-Hansen, Dorte; Halvorsen, Peder; Nexøe, Jørgen; Nielsen, Jesper; Støvring, Henrik; Kristiansen, Ivar
2011-01-01
When people make choices, they may have multiple options presented simultaneously or, alternatively, have options presented 1 at a time. It has been shown that if decision makers have little experience with or difficulties in understanding certain attributes, these attributes will have greater impact in joint evaluations than in separate evaluations. The authors investigated the impact of separate versus joint evaluations in a health care context in which laypeople were presented with the possibility of participating in risk-reducing drug therapies. In a randomized study comprising 895 subjects aged 40 to 59 y in Odense, Denmark, subjects were randomized to receive information in terms of absolute risk reduction (ARR), relative risk reduction (RRR), number needed to treat (NNT), or prolongation of life (POL), all with respect to heart attack, and they were asked whether they would be willing to receive a specified treatment. Respondents were randomly allocated to valuing the interventions separately (either great effect or small effect) or jointly (small effect and large effect). Joint evaluation reduced the propensity to accept the intervention that offered the smallest effect. Respondents were more sensitive to scale when faced with a joint evaluation for information formats ARR, RRR, and POL but not for NNT. Evaluability bias appeared to be most pronounced for POL and ARR. Risk information appears to be prone to evaluability bias. This suggests that numeric information on health gains is difficult to evaluate in isolation. Consequently, such information may bear too little weight in separate evaluations of risk-reducing interventions.
Testing of printed circuit board solder joints by optical correlation
NASA Technical Reports Server (NTRS)
Espy, P. N.
1975-01-01
An optical correlation technique for the nondestructive evaluation of printed circuit board solder joints was evaluated. Reliable indications of induced stress levels in solder joint lead wires are achievable. Definite relations between the inherent strength of a solder joint, with its associated ability to survive stress, are demonstrable.
ERIC Educational Resources Information Center
Chatterji, Madhabi
2005-01-01
This case study examines the applicability of 1994 standards, offered by the Joint Committee on Standards for Educational Evaluation, to evaluations conducted in international contexts. The work is undertaken in response to an open invitation from the Joint Committee in its 1994 publication. The article addresses two purposes. First, it asks…
Assessment of NDE Methods to Detect Lack of Fusion in HDPE Butt Fusion Joints
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crawford, Susan L.; Doctor, Steven R.; Cinson, Anthony D.
2011-07-31
Studies at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington, were conducted to evaluate nondestructive examinations (NDE) coupled with mechanical testing of butt fusion joints in high-density polyethylene (HDPE) pipe for assessing lack of fusion. The work provided information to the United States Nuclear Regulatory Commission (NRC) on the effectiveness of volumetric inspection techniques of HDPE butt fusion joints in Section III, Division 1, Class 3, buried piping systems in nuclear power plants. This paper describes results from assessments using ultrasonic and microwave nondestructive techniques and mechanical testing with the high-speed tensile impact test and the side-bend test formore » determining joint integrity. A series of butt joints were fabricated in 3408, 12-inch (30.5-cm) IPS DR-11 HDPE material by varying the fusion parameters to create good joints and joints containing a range of lack-of-fusion conditions. Six of these butt joints were volumetrically examined with time-of-flight diffraction (TOFD), phased-array (PA) ultrasound, and the Evisive microwave system. The outer diameter (OD) weld beads were removed for microwave evaluation and the pipes ultrasonically re-evaluated. In two of the six pipes, both the outer and inner diameter (ID) weld beads were removed and the pipe joints re-evaluated. Some of the pipes were sectioned and the joints destructively evaluated with the high-speed tensile test and the side-bend test. The fusion parameters, nondestructive and destructive evaluation results have been correlated to validate the effectiveness of what each NDE technology detects and what each does not detect. There was no single NDE method that detected all of the lack-of-fusion flaws but a combination of NDE methods did detect most of the flaws.« less
Aoyama, Shigeru; Kino, Koji; Shibuya, Toshihisa; Sato, Fumiaki; Kobayashi, Akiko; Yoshitake, Hiroyuki; Haketa, Tadasu; Amamori, Yoko; Ishikawa, Takayuki; Yoshida, Nahoko; Amagasa, Teruo
2003-09-01
We have carried out temporary silicone implants after diskectomies or arthroplasties in temporomandibular joint surgeries to avoid postoperative adhesion and to maintain articular space. We evaluated 19 joints in 15 patients who had received dacron-reinforced silicone implant after silicone sheet removal through follow-up for at least 6 months. The cases included temporomandibular joint disorder (10 joints in 9 patients), psoriatic arthritis (2 joints in 1 patient), ankylosis (4 joints in 3 patients) and synovial chondromatosis (2 joints in 2 patients). On the basis of the criteria of temporomandibular dysfunction for the results, they were classified as bad (4 patients). It is thought that factors other than the implant are related to the bad results in the postoperative evaluation. In this study, lymphadenopathy induced by exfoliated silicone debris could not be confirmed. The temporary silicone implant in the temporomandibular joint was thought to be useful.
Evaluation of tantalum 316 stainless steel transition joints
NASA Technical Reports Server (NTRS)
Stoner, D. R.
1972-01-01
Tubular transition joints providing a metallurgically bonded connection between tantalum and 316 stainless steel pipe sections were comparatively evaluated for durability under thermal cycling conditions approximating the operation of a SNAP-8 mercury boiler. Both coextruded and vacuum brazed transition joints of 50mm (2 inch) diameter were tested by thermal cycling 100 times between 730 C and 120 C(1350 F and 250 F) in a high vacuum environment. The twelve evaluated transition joints survived the full test sequence without developing leaks, although liquid penetrant bond line indications eventually developed in all specimens. The brazed transition joints exhibited the best dimensional stability and bond line durability.
Evaluation of Geosynthetics in Asphalt Overlays of Jointed Concrete Pavements
DOT National Transportation Integrated Search
2000-06-01
This report presents the findings and recommendations based on the Evaluation of Geosynthetics in Asphalt Overlays of Jointed Concrete Pavements. This project evaluated Linq Tac-711N and Strata Grid-200's ability to ease distress and reflective crack...
Cossich, Victor; Mallrich, Frédéric; Titonelli, Victor; de Sousa, Eduardo Branco; Velasques, Bruna; Salles, José Inácio
2014-01-01
To ascertain whether the proprioceptive deficit in the sense of joint position continues to be present when patients with a limb presenting a deficient anterior cruciate ligament (ACL) are assessed by testing their active reproduction of joint position, in comparison with the contralateral limb. Twenty patients with unilateral ACL tearing participated in the study. Their active reproduction of joint position in the limb with the deficient ACL and in the healthy contralateral limb was tested. Meta-positions of 20% and 50% of the maximum joint range of motion were used. Proprioceptive performance was determined through the values of the absolute error, variable error and constant error. Significant differences in absolute error were found at both of the positions evaluated, and in constant error at 50% of the maximum joint range of motion. When evaluated in terms of absolute error, the proprioceptive deficit continues to be present even when an active evaluation of the sense of joint position is made. Consequently, this sense involves activity of both intramuscular and tendon receptors.
Lins, Carolina Freitas; Lima de Sá Ribeiro, Daniel; Dourado Santos, Willer Gonçalves; Rosa, Genevievi; Machicado, Viviane; Pedreira, Ana Luisa; Pimenta da Fonseca, Emanuela; Mota Duque Sousa, Anna Paula; Rodrigues Silva, Carla Baleeiro; Matos, Marcos Antonio Almeida; Santiago, Mittermayer Barreto
2017-09-01
Diagnosis of synovitis/tenosynovitis by physical examination can be difficult. Ultrasound (US) can be an effective tool for the evaluation of joint involvement in systemic lupus erythematosus (SLE). This study will describe musculoskeletal findings by US in SLE patients and the evaluation of their correlation with physical examination. SLE patients underwent clinical/sonographic evaluation of hand/wrists. In total, 896 joints were evaluated: at least 1 change on physical examination was found in 136 joints and at least 1 US abnormality was found in 65 of 896 joints. Out of the 65 joints with US changes, only 13 had findings on physical examination. Conversely, 111 joints had tenderness on physical examination with no sonographic abnormalities. Tenosynovitis was statistically significant more frequently with joint edema (41%) (p = 0.0003). US can detect musculoskeletal changes in only a minority of symptomatic SLE patients. Clinical findings may be related to some reasons that cannot be explained using US. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Options as information: rational reversals of evaluation and preference.
Sher, Shlomi; McKenzie, Craig R M
2014-06-01
This article develops a rational analysis of an important class of apparent preference reversals-joint-separate reversals traditionally explained by the evaluability hypothesis. The "options-as-information" model considers a hypothetical rational actor with limited knowledge about the market distribution of a stimulus attribute. The actor's evaluations are formed via a 2-stage process-an inferential stage in which beliefs are updated on the basis of the sample of options received, followed by an assessment stage in which options are evaluated in light of these updated beliefs. This process generates joint-separate reversals in standard experimental designs. The normative model explains why the evaluability hypothesis works when it does, identifies boundary conditions for the hypothesis, and clarifies some common misconceptions about these effects. In particular, it implies that joint-separate reversals are not irrational; in fact, they are not preference reversals. However, in expanded designs where more than 2 options are jointly evaluated, the model predicts that genuine (and rational) preference reversals will sometimes emerge. Results of 3 experiments suggest an excellent fit between the rational actor model and the judgments of human actors in joint-separate experiments. PsycINFO Database Record (c) 2014 APA, all rights reserved.
In-game Management of Common Joint Dislocations
Skelley, Nathan W.; McCormick, Jeremy J.; Smith, Matthew V.
2014-01-01
Context: Sideline management of sports-related joint dislocations often places the treating medical professional in a challenging position. These injuries frequently require prompt evaluation, diagnosis, reduction, and postreduction management before they can be evaluated at a medical facility. Our objective is to review the mechanism, evaluation, reduction, and postreduction management of sports-related dislocations to the shoulder, elbow, finger, knee, patella, and ankle joints. Evidence Acquisition: A literature review was performed using the PubMed database to evaluate previous and current publications focused on joint dislocations. This review focused on articles published between 1980 and 2013. Study Design: Clinical review. Level of Evidence: Level 4. Results: The clinician should weigh the benefits and risks of on-field reduction based on their knowledge of the injury and the presence of associated injuries. Conclusion: When properly evaluated and diagnosed, most sports-related dislocations can be reduced and initially managed at the game. PMID:24790695
ERIC Educational Resources Information Center
Diamond, Esther E.
The growing demand for program evaluation in the 1970s gave rise to a need for a comprehensive, carefully developed, objective set of guiding principles for the evaluation process, from initial planning to final report. The Joint Committee on Standards for Education Evaluation was established to meet this need. This broad-based group, representing…
Lenzlinger-Asprion, Rahel; Keller, Niculina; Meichtry, André; Luomajoki, Hannu
2017-01-31
Hip joint complaints are a problem associated with increasing age and impair the mobility of a large section of the elderly population. Reliable and valid tests are necessary for a thorough investigation of a joint. A fundamental function of the hip joint is movement control and a test of this function forms a part of the standard examination. Until now there have been few scientific studies which specifically investigate the reliability of measurement tests of movement control of the hip joint. The aim of this study was to examine the intratester and intertester reliability of the movement control tests of the hip joint which are in use in current clinical practice. Sixteen participants with hip joint complaints and 14 without hip joint impairment were recruited. All participants performed five active movement control tests for the hip joint and were video filmed whilst performing these tests. These films formed the basis for the evaluation and were assessed by two independent physiotherapists. For the intertester and intratester reliability calculations specially set weighted kappa values and the calculated percentages were used. The intertester reliability of the five examined movement control tests of the hip joint showed good to almost perfect values (weighted kappa (wk) = 0.56-0.87). The intratester reliability of the more experienced evaluator A was better in regards to the less experienced evaluator B (average wk = 0.62 vs 0.38). The visual evaluation of movement control tests of the hip joint is especially reliable when carried out by an experienced evaluator. 4 out of 5 tests also showed good results for intertester reliability and support their use in clinical practice.
NASA Technical Reports Server (NTRS)
Cook, M.
1989-01-01
The procedures, performance, and results obtained from the Thiokol Corporation/Wasatch Redesigned Field Joint Protection System (FJPS) Installation Evaluation are documented. The purpose of the evaluation was to demonstrate and develop the procedures required to install two different concepts (referred to as Concepts 1 and 3) of the redesigned FJPS. The processing capability of each configuration was then evaluated and compared. The FJPS is installed on redesigned solid rocket motors (RSRM) to protect the field joints from rain intrusion and to maintain the joint temperature sensor measurement between 85 and 122 F while the boosters are on the launch pad. The FJPS is being redesigned to reduce installation timelines at KSC and to simplify or eliminate installation processing problems related to the present design of an EPDM moisture seal/extruded cork combination. Several installation techniques were evaluated, and a preferred method of application was developed for each concept. The installations were performed with the test article in the vertical (flight) position. Comparative timelines between the two concepts were also developed. An additional evaluation of the Concept 3 configuration was performed with the test article in the horizontal position, to simulate an overhead installation on a technical evaluation motor (TEM).
Asphaltic mixture compaction and density validation : research brief.
DOT National Transportation Integrated Search
2017-02-01
Research Objectives: : Evaluate HMA longitudinal joint type, method and compaction data to produce specification recommendations to ensure the highest density at longitudinal joints : Evaluate thin lift overlay HMA and provide recommendations...
Kalichman, Leonid; Klindukhov, Alexander; Li, Ling; Linov, Lina
2016-11-01
A reliability and cross-sectional observational study. To introduce a scoring system for visible fat infiltration in paraspinal muscles; to evaluate intertester and intratester reliability of this system and its relationship with indices of muscle density; to evaluate the association between indices of paraspinal muscle degeneration and facet joint osteoarthritis. Current evidence suggests that the paraspinal muscles degeneration is associated with low back pain, facet joint osteoarthritis, spondylolisthesis, and degenerative disc disease. However, the evaluation of paraspinal muscles on computed tomography is not radiological routine, probably because of absence of simple and reliable indices of paraspinal degeneration. One hundred fifty consecutive computed tomography scans of the lower back (N=75) or abdomen (N=75) were evaluated. Mean radiographic density (in Hounsfield units) and SD of the density of multifidus and erector spinae were evaluated at the L4-L5 spinal level. A new index of muscle degeneration, radiographic density ratio=muscle density/SD of density, was calculated. To evaluate the visible fat infiltration in paraspinal muscles, we proposed a 3-graded scoring system. The prevalence of facet joint osteoarthritis was also evaluated. Intraclass correlation and κ statistics were used to evaluate inter-rater and intra-rater reliability. Logistic regression examined the association between paraspinal muscle indices and facet joint osteoarthritis. Intra-rater reliability for fat infiltration score (κ) ranged between 0.87 and 0.92; inter-rater reliability between 0.70 and 0.81. Intra-rater reliability (intraclass correlation) for mean density of paraspinal muscles ranged between 0.96 and 0.99, inter-rater reliability between 0.95 and 0.99; SD intra-rater reliability ranged between 0.82 and 0.91, inter-rater reliability between 0.80 and 0.89. Significant associations (P<0.01) were found between facet joint osteoarthritis, fat infiltration score, and radiographic density ratio. Two suggested indices of paraspinal muscle degeneration showed excellent reliability and were significantly associated with facet joint osteoarthritis. Additional studies are needed to evaluate the associations with other spinal degeneration features and low back pain.
Dougados, Maxime; Jousse-Joulin, Sandrine; Mistretta, Frederic; d'Agostino, Maria-Antonietta; Backhaus, Marina; Bentin, Jacques; Chalès, Gérard; Chary-Valckenaere, Isabelle; Conaghan, Philip; Etchepare, Fabien; Gaudin, Philippe; Grassi, Walter; van der Heijde, Désirée; Sellam, Jérémie; Naredo, Esperanza; Szkudlarek, Marcin; Wakefield, Richard; Saraux, Alain
2010-05-01
To evaluate different global ultrasonographic (US) synovitis scoring systems as potential outcome measures of rheumatoid arthritis (RA) according to the Outcome Measures in Rheumatoid Arthritis Clinical Trials (OMERACT) filter. To study selected global scoring systems, for the clinical, B mode and power Doppler techniques, the following joints were evaluated: 28 joints (28-joint Disease Activity Score (DAS28)), 20 joints (metacarpophalangeals (MCPs) + metatarsophalangeals (MTPs)) and 38 joints (28 joints + MTPs) using either a binary (yes/no) or a 0-3 grade. The study was a prospective, 4-month duration follow-up of 76 patients with RA requiring anti-tumour necrosis factor (TNF) therapy (complete follow-up data: 66 patients). Intraobserver reliability was evaluated using the intraclass correlation coefficient (ICC), construct validity was evaluated using the Cronbach alpha test and external validity was evaluated using level of correlation between scoring system and C reactive protein (CRP). Sensitivity to change was evaluated using the standardised response mean. Discriminating capacity was evaluated using the standardised mean differences in patients considered by the doctor as significantly improved or not at the end of the study. Different clinimetric properties of various US scoring systems were at least as good as the clinical scores with, for example, intraobserver reliability ranging from 0.61 to 0.97 versus from 0.53 to 0.82, construct validity ranging from 0.76 to 0.89 versus from 0.76 to 0.88, correlation with CRP ranging from 0.28 to 0.34 versus from 0.28 to 0.35 and sensitivity to change ranging from 0.60 to 1.21 versus from 0.96 to 1.36 for US versus clinical scoring systems, respectively. This study suggests that US evaluation of synovitis is an outcome measure at least as relevant as physical examination. Further studies are required in order to achieve optimal US scoring systems for monitoring patients with RA in clinical trials and in clinical practice.
Biomechanical Evaluation of a Prototype Foot/Ankle Prosthesis
Quesada, P. M.; Pitkin, M.; Colvin, J.
2016-01-01
In this paper, we report on our pilot evaluation of a prototype foot/ankle prosthesis. This prototype has been designed and fabricated with the intention of providing decreased ankle joint stiffness during the middle portion of the stance phase of gait, and increased (i.e., more normal) knee range of motion during stance. Our evaluation involved fitting the existing prototype foot/ankle prosthesis, as well as a traditional solid ankle cushioned heel (SACH) foot, to an otherwise healthy volunteer with a below-knee (BK) amputation. We measured this individual’s lower extremity joint kinematics and kinetics during walking using a video motion analysis system and force platform. These measurements permitted direct comparison of prosthetic ankle joint stiffness and involved side knee joint motion, as well as prosthetic ankle joint moment and power. PMID:10779119
Exercise may decrease further destruction in the adult haemophilic joint.
Harris, S; Boggio, L N
2006-05-01
The effect of exercise on adult haemophilic joints was investigated. Forty-six subjects with existing joint disease were evaluated and range of motion (ROM) in joints was measured. The effect of exercise of large joint ROM in haemophilia was evaluated by comparing the ranges of motion in subjects who exercised at least three times weekly against those subjects who did not exercise. The exercise group showed improvement in the majority of joint ranges of motion compared with the non-exercise group (P = 0.003). Thus regular exercise may help reduce further destruction in haemophilic joints by strengthening muscle ligaments and tendons surrounding the joint thereby protecting them from damage caused by recurrent haemarthrotic events.
Evaluating Intra-Articular Drug Delivery for the Treatment of Osteoarthritis in a Rat Model
Allen, Kyle D.; Adams, Samuel B.
2010-01-01
Osteoarthritis (OA) is a degenerative joint disease that can result in joint pain, loss of joint function, and deleterious effects on activity levels and lifestyle habits. Current therapies for OA are largely aimed at symptomatic relief and may have limited effects on the underlying cascade of joint degradation. Local drug delivery strategies may provide for the development of more successful OA treatment outcomes that have potential to reduce local joint inflammation, reduce joint destruction, offer pain relief, and restore patient activity levels and joint function. As increasing interest turns toward intra-articular drug delivery routes, parallel interest has emerged in evaluating drug biodistribution, safety, and efficacy in preclinical models. Rodent models provide major advantages for the development of drug delivery strategies, chiefly because of lower cost, successful replication of human OA-like characteristics, rapid disease development, and small joint volumes that enable use of lower total drug amounts during protocol development. These models, however, also offer the potential to investigate the therapeutic effects of local drug therapy on animal behavior, including pain sensitivity thresholds and locomotion characteristics. Herein, we describe a translational paradigm for the evaluation of an intra-articular drug delivery strategy in a rat OA model. This model, a rat interleukin-1β overexpression model, offers the ability to evaluate anti-interleukin-1 therapeutics for drug biodistribution, activity, and safety as well as the therapeutic relief of disease symptoms. Once the action against interleukin-1 is confirmed in vivo, the newly developed anti-inflammatory drug can be evaluated for evidence of disease-modifying effects in more complex preclinical models. PMID:19943805
Seo, Jimyung; Lee, Minseok; Choi, Min Ju; Zheng, Zhenlong; Cho, Arthur; Bang, Dongsik; Kim, Do Young
2015-01-01
Behçet's disease (BD) is a multisystemic inflammatory disease with articular involvement. Non-specific arthralgia without objective signs of arthritis, such as swelling or effusion, is common in such patients. Thus, an accurate diagnosis of joint involvement may be challenging for dermatologists. To evaluate the validity of (99m)Tc-methylene diphosphonate (Tc-99m-MDP) bone scintigraphy for joint involvement assessment in patients with BD. In 211 patients with BD who had scintigraphic evaluations due to joint symptoms, agreement between bone scintigraphy findings and clinically evaluated joint complaints was retrospectively assessed using Cohen's kappa (κ) statistic. A patient subset (n = 104) showing agreement between joint complaints and scintigraphy results was re-evaluated by a rheumatologist to determine the level of diagnostic specificity attained by combining bone scintigraphy with clinical examinations of dermatologists. The total kappa value (211 patients) was 0.604, indicating fair agreement between joint complaints and scintigraphy results. Individual analysis of eleven joint categories revealed statistically significant correlations for wrist (κ = 0.677), shoulder (κ = 0.661), and foot joints (κ = 0.618). Of the 104 referrals to a rheumatologist, 95 (91.34%) were confirmed as having BD-associated articular involvement. Joint acral areas (e.g., foot, hand, wrist and shoulder) that had the highest kappa value correlations also ranked highest in diagnostic specificity. Bone scintigraphy presents a simple and useful option for dermatologists to assess joint involvement in BD patients, especially for specific anatomic sites.
Premature deterioration of jointed plain concrete pavements.
DOT National Transportation Integrated Search
2011-04-29
Six sections of jointed plain concrete pavements (JPCP)s throughout the state were selected as candidates for the evaluation of premature deterioration. The data used in performing the evaluation included manual and historic automated distress survey...
Premature deterioration of jointed plain concrete pavements.
DOT National Transportation Integrated Search
2011-04-29
Six sections of jointed plain concrete pavements (JPCP)s throughout the state were selected as : candidates for the evaluation of premature deterioration. The data used in performing the evaluation included manual : and historic automated distress su...
Ren, Yupeng; Kang, Sang Hoon; Park, Hyung-Soon; Wu, Yi-Ning; Zhang, Li-Qun
2013-05-01
Arm impairments in patients post stroke involve the shoulder, elbow and wrist simultaneously. It is not very clear how patients develop spasticity and reduced range of motion (ROM) at the multiple joints and the abnormal couplings among the multiple joints and the multiple degrees-of-freedom (DOF) during passive movement. It is also not clear how they lose independent control of individual joints/DOFs and coordination among the joints/DOFs during voluntary movement. An upper limb exoskeleton robot, the IntelliArm, which can control the shoulder, elbow, and wrist, was developed, aiming to support clinicians and patients with the following integrated capabilities: 1) quantitative, objective, and comprehensive multi-joint neuromechanical pre-evaluation capabilities aiding multi-joint/DOF diagnosis for individual patients; 2) strenuous and safe passive stretching of hypertonic/deformed arm for loosening up muscles/joints based on the robot-aided diagnosis; 3) (assistive/resistive) active reaching training after passive stretching for regaining/improving motor control ability; and 4) quantitative, objective, and comprehensive neuromechanical outcome evaluation at the level of individual joints/DOFs, multiple joints, and whole arm. Feasibility of the integrated capabilities was demonstrated through experiments with stroke survivors and healthy subjects.
Evaluation of musculoskeletal sepsis with indium-111 white blood cell imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ouzounian, T.J.; Thompson, L.; Grogan, T.J.
The detection of musculoskeletal sepsis, especially following joint replacement, continues to be a challenging problem. Often, even with invasive diagnostic evaluation, the diagnosis of infection remains uncertain. This is a report on the first 55 Indium-111 white blood cell (WBC) images performed in 39 patients for the evaluation of musculoskeletal sepsis. There were 40 negative and 15 positive Indium-111 WBC images. These were correlated with operative culture and tissue pathology, aspiration culture, and clinical findings. Thirty-eight images were performed for the evaluation of possible total joint sepsis (8 positive and 30 negative images); 17 for the evaluation of nonarthroplasty-related musculoskeletalmore » sepsis (7 positive and 10 negative images). Overall, there were 13 true-positive, 39 true-negative, two false-positive, and one false-negative images. Indium-111 WBC imaging is a sensitive and specific means of evaluating musculoskeletal sepsis, especially following total joint replacement.« less
Son, Ye Na; Jin, Wook; Jahng, Geon-Ho; Cha, Jang Gyu; Park, Yong Sung; Yun, Seong Jong; Park, So Young; Park, Ji Seon; Ryu, Kyung Nam
2018-02-01
To investigate the efficacy of double inversion recovery (DIR) sequence for evaluating the synovium of the femoro-patellar joint without contrast enhancement (CE). Two radiologists independently evaluated the axial DIR and CE T1-weighted fat-saturated (CET1FS) images of 33 knees for agreement; the visualisation and distribution of the synovium were evaluated using a four-point visual scaling system at each of the five levels of the femoro-patellar joint and the location of the thickest synovium. The maximal synovial thickness at each sequence was measured by consensus. The interobserver agreement was good (κ = 0.736) for the four-point scale, and was excellent for the location of the thickest synovium on DIR and CET1FS (κ = 0.955 and 0.954). The intersequential agreement for the area with the thickest synovium was also excellent (κ = 0.845 and κ = 0.828). The synovial thickness on each sequence showed excellent correlation (r = 0.872). The DIR showed as good a correlation as CET1FS for the evaluation of the synovium at the femoro-patellar joint. DIR may be a useful MR technique for evaluating the synovium without CE. • DIR can be useful for evaluating the synovium of the femoro-patellar joint. • Interobserver and intersequential agreements between DIR and CET1FS were good. • Mean thickness of the synovium was significantly different between two sequences.
Borotikar, Bhushan; Lempereur, Mathieu; Lelievre, Mathieu; Burdin, Valérie; Ben Salem, Douraied; Brochard, Sylvain
2017-01-01
To report evidence for the concurrent validity and reliability of dynamic MRI techniques to evaluate in vivo joint and muscle mechanics, and to propose recommendations for their use in the assessment of normal and impaired musculoskeletal function. The search was conducted on articles published in Web of science, PubMed, Scopus, Academic search Premier, and Cochrane Library between 1990 and August 2017. Studies that reported the concurrent validity and/or reliability of dynamic MRI techniques for in vivo evaluation of joint or muscle mechanics were included after assessment by two independent reviewers. Selected articles were assessed using an adapted quality assessment tool and a data extraction process. Results for concurrent validity and reliability were categorized as poor, moderate, or excellent. Twenty articles fulfilled the inclusion criteria with a mean quality assessment score of 66% (±10.4%). Concurrent validity and/or reliability of eight dynamic MRI techniques were reported, with the knee being the most evaluated joint (seven studies). Moderate to excellent concurrent validity and reliability were reported for seven out of eight dynamic MRI techniques. Cine phase contrast and real-time MRI appeared to be the most valid and reliable techniques to evaluate joint motion, and spin tag for muscle motion. Dynamic MRI techniques are promising for the in vivo evaluation of musculoskeletal mechanics; however results should be evaluated with caution since validity and reliability have not been determined for all joints and muscles, nor for many pathological conditions.
Evaluation of Brazed Joints Using Failure Assessment Diagram
NASA Technical Reports Server (NTRS)
Flom, Yury
2012-01-01
Fitness-for service approach was used to perform structural analysis of the brazed joints consisting of several base metal / filler metal combinations. Failure Assessment Diagrams (FADs) based on tensile and shear stress ratios were constructed and experimentally validated. It was shown that such FADs can provide a conservative estimate of safe combinations of stresses in the brazed joints. Based on this approach, Margins of Safety (MS) of the brazed joints subjected to multi-axial loading conditions can be evaluated..
An evaluation of charity care for tax-exempt hospitals engaging in joint ventures.
Smith, Pamela C
2006-01-01
The study examines whether the level of charity care and financial stability contribute to a nonprofit hospital's motivation for partnering with a for-profit hospital through a joint venture. The Internal Revenue Service (IRS) has heightened its scrutiny of joint ventures within the health care sector. Considering recent calls to investigate the merit of the tax-exempt status of hospitals engaged in joint ventures, this research will assist policy makers in the evaluation of nonprofit hospitals. Constituents will continue to question whether joint ventures contribute to a reduced focus on charitable activities. Results indicate that the propensity to engage in a joint venture significantly increases with increased levels of charity care. Furthermore, nonprofit hospitals with lower profitability are more likely to engage in joint ventures. These results are useful to policy makers when evaluating the level of charity care provided by hospitals seeking alternative strategic alliances. Considering many critics allege hospitals are reducing the provision of charity care to the community, it is imperative for management to be conscious of the impact of joint ventures on the provision of charity care.
Kan, Hiroyuki; Arai, Yuji; Kobayashi, Masashi; Nakagawa, Shuji; Inoue, Hiroaki; Hino, Manabu; Komaki, Shintaro; Ikoma, Kazuya; Ueshima, Keiichiro; Fujiwara, Hiroyoshi; Kubo, Toshikazu
2017-01-01
Purpose The fixed flexion view (FFV) of the knee is considered useful for evaluating the joint space when assessing the severity of osteoarthritis (OA) of the knee. To clarify the usefulness of FFV for evaluation of the joint space and severity of knee OA, this study evaluated changes in the joint space on the FFV and standing extended view (SEV) in patients with knee OA. Materials and Methods The SEV and FFV images were acquired in 567 patients (1,102 knees) who visited the hospital with a chief complaint of knee joint pain. Medial joint space width (MJSW) and Kellgren-Lawrence (K-L) classification assessed using the SEV and FFV images were compared. Results Mean MJSW was significantly smaller when assessed on the FFV than on the SEV (3.02±1.55 mm vs. 4.31±1.30 mm; p<0.001). The K-L grade was the same or higher on the FFV than on the SEV. Conclusions The FFV is more useful than the SEV for evaluating the joint space in OA knees. Treatment strategies in patients with knee OA should be determined based on routinely acquired FFV images. PMID:28231651
Joint High Speed Vessel (JHSV) Follow on Operational Test and Evaluation (FOT and E) Report
2015-09-21
Speed Vessel (JHSV) ship class. The events covered in this testing were not performed during the Initial Operational Test and Evaluation ( IOT &E...support boats since launch of these type boats was completed in IOT &E. 1 “Initial Operational Test...and Evaluation ( IOT &E) with Live Fire Test and Evaluation (LFT&E) on Joint High Speed Vessel (JHSV),” DOT&E, July 17, 2014. 2 MLP (CCS) is a heavy
The Case for a Joint Evaluation
2017-01-01
intelligence, and engineering. Finally, the comparative time ex - pended by the combatant commanders (CCDRs) on fulfilling four different evaluation...template for the joint-centric construct would align with the four de facto sections noted earlier: an identifica- tion section, a performance metric...intangible or have not been properly researched. For example, under one evaluation system, a Servicemember’s separation or retire- ment into a post
Experimental evaluation of joint designs for a space-shuttle orbiter ablative leading edge
NASA Technical Reports Server (NTRS)
Tompkins, S. S.; Kabana, W. P.
1975-01-01
The thermal performance of two types of ablative leading-edge joints for a space-shuttle orbiter were tested and evaluated. Chordwise joints between ablative leading-edge segments, and spanwise joints between ablative leading-edge segments and reusable surface insulation tiles were exposed to simulated shuttle heating environments. The data show that the thermal performance of models with chordwise joints to be as good as jointless models in simulated ascent-heating and orbital cold-soak environments. The suggestion is made for additional work on the joint seals, and, in particular, on the effects of heat-induced seal-material surface irregularities on the local flow.
Seiler, Gabriela S; Häni, Hansjürg; Busato, André R; Lang, Johann
2002-01-01
To evaluate the possible association between facet joint geometry and intervertebral disk degeneration in German Shepherd Dogs. 25 German Shepherd Dogs and 11 control dogs of similar body weight and condition. Facet joint angles in the caudal portion of the lumbar region of the vertebral column (L5-S1) were measured by use of computed tomography, and the intervertebral discs were evaluated microscopically. The relationship between facet joint geometry and disk degeneration was evaluated by use of statistical methods. German Shepherd Dogs had significantly more facet joint tropism than control dogs, but an association with disk degeneration was not found. However, German Shepherd Dogs had a different facet joint conformation, with more sagittally oriented facet joints at L5-L6 and L6-L7 and a larger angle difference between the lumbar and lumbosacral facet joints, compared with control dogs. A large difference between facet joint angles at L6-L7 and L7-S1 in German Shepherd Dogs may be associated with the frequent occurrence of lumbosacral disk degeneration in this breed.
Evaluation of joint sealant materials : final report.
DOT National Transportation Integrated Search
1977-05-01
In May, 1968, the Department's Research and Development Section initiated a project to evaluate joint sealants being marketed for use on roads and bridges. In the study, representatives of 31 companies installed 40 products primarily on one road and ...
JUPITER PROJECT - JOINT UNIVERSAL PARAMETER IDENTIFICATION AND EVALUATION OF RELIABILITY
The JUPITER (Joint Universal Parameter IdenTification and Evaluation of Reliability) project builds on the technology of two widely used codes for sensitivity analysis, data assessment, calibration, and uncertainty analysis of environmental models: PEST and UCODE.
Field evaluation of three joint sealants.
DOT National Transportation Integrated Search
1987-01-01
The purpose of the study reported here was to evaluate the performance of three joint sealants compartmented (A) and closed cellular (B) preformed neoprene, and a two-component cold-mixed polysulfide (C)-- that were used in the interchanges for Inter...
PCC/AC shoulder joint seal evaluation
DOT National Transportation Integrated Search
1999-05-07
This report presents the findings on the evaluation of Crafco Incorporated Roadsaver 903 SL Silicone Sealant and Dow Corning 890 SL Silicone Sealant. The Research Technical Panel had proposed to use the two self-leveling silicone joint sealants in te...
Evaluation of subsurface damage in concrete deck joints using impact echo method
Rickard, Larry; Choi, Wonchang
2016-01-01
Many factors can affect the overall performance and longevity of highway bridges, including the integrity of their deck joints. This study focuses on the evaluation of subsurface damage in deteriorated concrete deck joints, which includes the delamination and corrosion of the reinforcement. Impact echo and surface wave technology, mainly a portable seismic property analyzer (PSPA), were employed to evaluate the structural deficiency of concrete joints. Laboratory tests of core samples were conducted to verify the nondestructive test results. As a result, the primary advantage of the PSPA as a bridge assessment tool lies in its ability to assess the concrete’smore » modulus and to detect subsurface defects at a particular point simultaneously.« less
Nondestructive Evaluation of Adhesively Bonded Joints
NASA Technical Reports Server (NTRS)
Nayeb-Hashemi, Hamid; Rossettos, J. N.
1997-01-01
The final report consists of 5 published papers in referred journals and a technical letter to the technical monitor. These papers include the following: (1) Comparison of the effects of debonds and voids in adhesive; (2) On the peak shear stresses in adhesive joints with voids; (3) Nondestructive evaluation of adhesively bonded joints by acousto-ultrasonic technique and acoustic emission; (4) Multiaxial fatigue life evaluation of tubular adhesively bonded joints; (5) Theoretical and experimental evaluation of the bond strength under peeling loads. The letter outlines the progress of the research. Also included is preliminary information on the study of nondestructive evaluation of composite materials subjected to localized heat damage. The investigators studied the effects of localized heat on unidirectional fiber glass epoxy composite panels. Specimens of the fiber glass epoxy composites were subjected to 400 C heat for varying lengths of time. The specimens were subjected to nondestructive tests. The specimens were then pulled to their failure and acoustic emission of these specimens were measured. The analysis of the data was continuing as of the writing of the letter, and includes a finite element stress analysis of the problem.
Joint angle sensors for closed-loop control
NASA Astrophysics Data System (ADS)
Ko, Wen H.; Miao, Chih-Lei
In order to substitute braces that have built-in goniometers and to provide feedback signals for closed loop control of lower extremity Functional Neuromuscular System in paraplegics, a stretchable capacitive sensor was developed to accurately detect angular movement in joints. Promising clinical evaluations on the knee joints of a paraplegic and a volunteer were done. The evaluations show great promise for the possibility of implantation applications.
Evaluation of notched wedge pavement joints vs. traditional butt joints for use in Connecticut.
DOT National Transportation Integrated Search
2008-01-01
Following up on earlier research performed by several states and the : National Center for Asphalt Technology (NCAT) at Auburn University, the : University of Connecticuts Advanced Pavement Lab (CAP Lab) was : charged with evaluating the longitudi...
Evaluation of TransTech joint maker and precompaction screed.
DOT National Transportation Integrated Search
2000-09-01
The primary objective of this evaluation is to determine the effectiveness of the Joint Maker and Precompaction : Screed, both developed by TransTech Systems, Inc., in achieving higher and more uniform density across the mat of : a rehabilitated Hot ...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-04
... War on Terror Heroes, VA and the Department of Defense (DOD) have agreed to develop a joint process in which Global War on Terror (GWOT) service members are evaluated to assign disability ratings, which will...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-13
... Global War on Terror Heroes, VA and the Department of Defense (DOD) have agreed to develop a joint process in which Global War on Terror (GWOT) service member's are evaluated to assign disability ratings...
Durability of saw-cut joints in plain cement concrete pavements.
DOT National Transportation Integrated Search
2011-01-01
The objective of this project was to evaluate factors influencing the durability of the joints in portland cement concrete : pavement in the state of Indiana. Specifically this work evaluated the absorption of water, the absorption of deicing solutio...
WisDOT asphaltic mixture new specifications implementation : field compaction and density.
DOT National Transportation Integrated Search
2016-06-01
The main research objectives of this study were to evaluate HMA Longitudinal Joint type, method and compaction data to produce specification recommendations that will ensure the highest density longitudinal joint, as well as evaluate and produce a sp...
Lempereur, Mathieu; Lelievre, Mathieu; Burdin, Valérie; Ben Salem, Douraied; Brochard, Sylvain
2017-01-01
Purpose To report evidence for the concurrent validity and reliability of dynamic MRI techniques to evaluate in vivo joint and muscle mechanics, and to propose recommendations for their use in the assessment of normal and impaired musculoskeletal function. Materials and methods The search was conducted on articles published in Web of science, PubMed, Scopus, Academic search Premier, and Cochrane Library between 1990 and August 2017. Studies that reported the concurrent validity and/or reliability of dynamic MRI techniques for in vivo evaluation of joint or muscle mechanics were included after assessment by two independent reviewers. Selected articles were assessed using an adapted quality assessment tool and a data extraction process. Results for concurrent validity and reliability were categorized as poor, moderate, or excellent. Results Twenty articles fulfilled the inclusion criteria with a mean quality assessment score of 66% (±10.4%). Concurrent validity and/or reliability of eight dynamic MRI techniques were reported, with the knee being the most evaluated joint (seven studies). Moderate to excellent concurrent validity and reliability were reported for seven out of eight dynamic MRI techniques. Cine phase contrast and real-time MRI appeared to be the most valid and reliable techniques to evaluate joint motion, and spin tag for muscle motion. Conclusion Dynamic MRI techniques are promising for the in vivo evaluation of musculoskeletal mechanics; however results should be evaluated with caution since validity and reliability have not been determined for all joints and muscles, nor for many pathological conditions. PMID:29232401
Performance of concrete joint sealants in hot climates
DOT National Transportation Integrated Search
1987-11-01
A research project was initiated in 1979 on project IR-17-1(126) to compare and evaluate several joint sealants. In 1982 another test section on project F 028-1-506 was established to evaluate several other sealants. This report documents the placeme...
Ono, Yohei; Kashihara, Rina; Yasojima, Nobutoshi; Kasahara, Hideki; Shimizu, Yuka; Tamura, Kenichi; Tsutsumi, Kaori; Sutherland, Kenneth; Koike, Takao; Kamishima, Tamotsu
2016-06-01
Accurate evaluation of joint space width (JSW) is important in the assessment of rheumatoid arthritis (RA). In clinical radiography of bilateral hands, the oblique incidence of X-rays is unavoidable, which may cause perceptional or measurement error of JSW. The objective of this study was to examine whether tomosynthesis, a recently developed modality, can facilitate a more accurate evaluation of JSW than radiography under the condition of oblique incidence of X-rays. We investigated quantitative errors derived from the oblique incidence of X-rays by imaging phantoms simulating various finger joint spaces using radiographs and tomosynthesis images. We then compared the qualitative results of the modified total Sharp score of a total of 320 joints from 20 patients with RA between these modalities. A quantitative error was prominent when the location of the phantom was shifted along the JSW direction. Modified total Sharp scores of tomosynthesis images were significantly higher than those of radiography, that is to say JSW was regarded as narrower in tomosynthesis than in radiography when finger joints were located where the oblique incidence of X-rays is expected in the JSW direction. Tomosynthesis can facilitate accurate evaluation of JSW in finger joints of patients with RA, even with oblique incidence of X-rays. Accurate evaluation of JSW is necessary for the management of patients with RA. Through phantom and clinical studies, we demonstrate that tomosynthesis may achieve more accurate evaluation of JSW.
NASA Astrophysics Data System (ADS)
Nagai, Yukie; Hosoda, Koh; Morita, Akio; Asada, Minoru
This study argues how human infants acquire the ability of joint attention through interactions with their caregivers from a viewpoint of cognitive developmental robotics. In this paper, a mechanism by which a robot acquires sensorimotor coordination for joint attention through bootstrap learning is described. Bootstrap learning is a process by which a learner acquires higher capabilities through interactions with its environment based on embedded lower capabilities even if the learner does not receive any external evaluation nor the environment is controlled. The proposed mechanism for bootstrap learning of joint attention consists of the robot's embedded mechanisms: visual attention and learning with self-evaluation. The former is to find and attend to a salient object in the field of the robot's view, and the latter is to evaluate the success of visual attention, not joint attention, and then to learn the sensorimotor coordination. Since the object which the robot looks at based on visual attention does not always correspond to the object which the caregiver is looking at in an environment including multiple objects, the robot may have incorrect learning situations for joint attention as well as correct ones. However, the robot is expected to statistically lose the learning data of the incorrect ones as outliers because of its weaker correlation between the sensor input and the motor output than that of the correct ones, and consequently to acquire appropriate sensorimotor coordination for joint attention even if the caregiver does not provide any task evaluation to the robot. The experimental results show the validity of the proposed mechanism. It is suggested that the proposed mechanism could explain the developmental mechanism of infants' joint attention because the learning process of the robot's joint attention can be regarded as equivalent to the developmental process of infants' one.
Kobayashi, Toshiki; Leung, Aaron K L; Akazawa, Yasushi; Hutchins, Stephen W
2011-01-01
To investigate the methodology using a manual ankle joint resistive torque measurement device to evaluate the contribution of the neural component of ankle joint resistive torque in patients with stroke. Within-subject comparison to compare the ankle joint resistive torque between fast and slow stretching conditions. Ten patients with stroke participated in this study. The incremental ratio of ankle joint resistive torque at the ankle angular position of 5degrees dorsiflexion under the fast stretching condition in comparison to the slow one was calculated in each patient. A significant increase (p<0.01) in the ankle joint resistive torque was demonstrated under the fast stretching condition in comparison to the slow one in all patients and the mean ankle joint resistive torque was 4.6 (SD=1.7) Nm under the slow stretching condition, while it was 8.4 (SD=4.1) Nm under the fast stretching condition at the ankle angular position of 5 degrees dorsiflexion. The incremental ratio ranged from 9.4-139.3% among the patients. The results of this study demonstrated the potential advantage of the device to evaluate the contribution of the neural component of ankle joint resistive torque.
Durability of saw-cut joints in plain cement concrete pavements : [technical summary].
DOT National Transportation Integrated Search
2011-01-01
The main objective of this study was to evaluate factors influencing the durability of the joints in portland cement concrete pavement in the state of Indiana. : The scope of the research included the evaluation of the absorption of water in concrete...
The open-source, public domain JUPITER (Joint Universal Parameter IdenTification and Evaluation of Reliability) API (Application Programming Interface) provides conventions and Fortran-90 modules to develop applications (computer programs) for analyzing process models. The input ...
Effect of patient positions on measurement errors of the knee-joint space on radiographs
NASA Astrophysics Data System (ADS)
Gilewska, Grazyna
2001-08-01
Osteoarthritis (OA) is one of the most important health problems these days. It is one of the most frequent causes of pain and disability of middle-aged and old people. Nowadays the radiograph is the most economic and available tool to evaluate changes in OA. Error of performance of radiographs of knee joint is the basic problem of their evaluation for clinical research. The purpose of evaluation of such radiographs in my study was measuring the knee-joint space on several radiographs performed at defined intervals. Attempt at evaluating errors caused by a radiologist of a patient was presented in this study. These errors resulted mainly from either incorrect conditions of performance or from a patient's fault. Once we have information about size of the errors, we will be able to assess which of these elements have the greatest influence on accuracy and repeatability of measurements of knee-joint space. And consequently we will be able to minimize their sources.
Prevention of the Posttraumatic Fibrotic Response in Joints
2015-10-01
used on a regular basis. Major Task 4: Evaluating the efficacy of inhibitory chIgG to reduce the consequences of traumatic joint injury. During...the second year of study, we successfully employed all assays needed to evaluate the utility of the inhibitory antibody to reduce the flexion...1. Major Task 5: Task 4. Data analysis and statistical evaluation of results. All data from the mechanical measurements, from the biochemical
Joint ventures: to pursue or not to pursue?
Blaszyk, Michael D; Hill-Mischel, Jody
2007-11-01
Hospitals should carefully select joint venture partners. The joint venture evaluation process should involve a high-level screen of strategic opportunities. Hospitals should develop a full business plan for the joint venture.
Installation and performance evaluation of the wabocrete FMV joint system for bridge decks.
DOT National Transportation Integrated Search
1990-01-01
A Wabocrete FMV bridge deck expansion joint system was installed on the Alternate Rte. 58 bridge over the Clinch River in November 1986. The bridge was placed in service in mid-1987. The report concerns an installation and performance evaluation of t...
Evaluation of pipe-type cable joint restraint systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Silver, D.A.; Seman, G.W.
1990-03-01
the purpose of this project was to evaluate two systems for restraining the movement of 345kV high-pressure oil-filled (HPOF) cable joints during load cycling. Problems with joints and adjacent cables due to thermomechanical bending (TMB) experienced by the Consolidated Edison Company of New York and Public Service Electric Gas Company of New Jersey are reviewed. Some approaches to reducing or preventing TMB induced damage to HPOF pipe type cable joints are discussed. The design and operation of a special test apparatus for simulating TMB effects under laboratory conditions is described. One of the two joint restraint systems evaluated under thismore » project was developed by PSE G and employed wedging devices, which could be retrofitted into existing installations, that limited the longitudinal movement of the joints during load cycling. The other system developed by Pirelli Cable Corporation applied the restraining force to the cylindrical portion of the hand applied joint insulation by means of support spiders and steel rods attached to the reducer faces. The test results show that the PSE G restraint system can effectively limit joint longitudinal movement while causing a minimal amount of mechanical disturbance to the joint stress cones. The test results obtained with the PCC system are inconclusive and indicate that further refinement and testing are required to demonstrate the effectiveness of this promising joint restraint system.« less
Xie, Qing-tiao; Huang, Xuan-ping; Jiang, Xian-fang; Yang, Yuan-yuan; Li, Hua; Lin, Xi
2013-08-01
To evaluate the clinical effect of joint reconstruction by using autogenous coronoid process graft to treat temporomandibular joint(TMJ) ankylosis. Nine cases of TMJ ankylosis from September 2008 to September 2010 were surgically treated by joint reconstruction with autogenous coronoid process graft, using autogenous articular disc or prosthodontic membrane as interpositional material. Mouth opening, occlusion and cone beam CT(CBCT) were used for evaluation before and after surgery. Satisfactory mouth opening was achieved in all patients and no one got occlusal changes or reankylosis during follow-up. CBCT showed that coronoid process graft reached bone union with the ramus and turned to be round. It is effective to cure TMJ ankylosis through joint reconstruction with autogenous coronoid process graft.
Prevention of the Posttraumatic Fibrotic Response in Joints
2015-10-01
are currently used on a regular basis. Major Task 4: Evaluating the efficacy of inhibitory chIgG to reduce the consequences of traumatic joint...injury. During the second year of study, we successfully employed all assays needed to evaluate the utility of the inhibitory antibody to reduce the...32nd week 1. Major Task 5: Task 4. Data analysis and statistical evaluation of results. All data from the mechanical measurements, from the
Prevention of the Posttraumatic Fibrotic Response in Joints
2015-10-01
surgical procedures and subsequent collection of tissues have been developed and are currently used on a regular basis. Major Task 4: Evaluating the...needed to evaluate the utility of the inhibitory antibody to reduce the flexion contracture of injured knee joints. The employed techniques include...second surgery to remove a pin, and it did not change by the end of the 32nd week 1. Major Task 5: Task 4. Data analysis and statistical evaluation
HMA Longitudinal Joint Evaluation and Construction
DOT National Transportation Integrated Search
2011-02-01
Longitudinal joint quality is essential to the successful performance of asphalt pavements. A number of states have begun to implement longitudinal joint specifications, and most are based on determinations of density. However, distress at the joint ...
Evaluation of the chondral modeling theory using fe-simulation and numeric shape optimization
Plochocki, Jeffrey H; Ward, Carol V; Smith, Douglas E
2009-01-01
The chondral modeling theory proposes that hydrostatic pressure within articular cartilage regulates joint size, shape, and congruence through regional variations in rates of tissue proliferation.The purpose of this study is to develop a computational model using a nonlinear two-dimensional finite element analysis in conjunction with numeric shape optimization to evaluate the chondral modeling theory. The model employed in this analysis is generated from an MR image of the medial portion of the tibiofemoral joint in a subadult male. Stress-regulated morphological changes are simulated until skeletal maturity and evaluated against the chondral modeling theory. The computed results are found to support the chondral modeling theory. The shape-optimized model exhibits increased joint congruence, broader stress distributions in articular cartilage, and a relative decrease in joint diameter. The results for the computational model correspond well with experimental data and provide valuable insights into the mechanical determinants of joint growth. The model also provides a crucial first step toward developing a comprehensive model that can be employed to test the influence of mechanical variables on joint conformation. PMID:19438771
Mourcou, Quentin; Fleury, Anthony; Diot, Bruno; Franco, Céline; Vuillerme, Nicolas
2015-01-01
Assessment of joint functional and proprioceptive abilities is essential for balance, posture, and motor control rehabilitation. Joint functional ability refers to the capacity of movement of the joint. It may be evaluated thereby measuring the joint range of motion (ROM). Proprioception can be defined as the perception of the position and of the movement of various body parts in space. Its role is essential in sensorimotor control for movement acuity, joint stability, coordination, and balance. Its clinical evaluation is commonly based on the assessment of the joint position sense (JPS). Both ROM and JPS measurements require estimating angles through goniometer, scoliometer, laser-pointer, and bubble or digital inclinometer. With the arrival of Smartphones, these costly clinical tools tend to be replaced. Beyond evaluation, maintaining and/or improving joint functional and proprioceptive abilities by training with physical therapy is important for long-term management. This review aims to report Smartphone applications used for measuring and improving functional and proprioceptive abilities. It identifies that Smartphone applications are reliable for clinical measurements and are mainly used to assess ROM and JPS. However, there is lack of studies on Smartphone applications which can be used in an autonomous way to provide physical therapy exercises at home. PMID:26583101
Materials testing protocol for small joint prostheses.
Savory, K M; Hutchinson, D T; Bloebaum, R
1994-10-01
In this article, a protocol for the evaluation of new materials for small joint prostheses is introduced. The testing methods employed in the protocol were developed by reviewing reported clinical failure modes and conditions found in vivo. The methods developed quantitatively evaluates the fatigue, fatigue crack propagation, and wear resistance properties of materials. For this study, a silicone elastomer similar to Dow Corning Silastic HP100, a radiation stable polypropylene, and a copolymer of polypropylene and ethylene propylene-diene monomer (EPDM) are evaluated. None of the materials tested demonstrated the ideal properties that are sought in a self-hinging joint prostheses. The silicone elastomer had excellent wear properties; however, cracks quickly propagated, causing catastrophic failure when fatigued. Conversely, the copolymer showed excellent fatigue crack propagation resistance and less than favorable wear properties. The polypropylene did not perform well in any evaluation.
Armstrong, April
2014-07-01
Shoulder pain is a common reason for a patient to see their primary care physician. This article focuses on the evaluation and management of 3 common shoulder disorders; rotator cuff disorders, acromioclavicular joint arthritis, and glenohumeral joint arthritis. The typical history and physical examination findings for each of these entities are highlighted, in addition to treatment options. Copyright © 2014 Elsevier Inc. All rights reserved.
2011-06-01
Committee Meeting. 23 June 2008. Bjorkman, Eileen A. and Frank B. Gray . “Testing in a Joint Environment 2004-2008: Findings, Conclusions and...the LVC joint test environment to evaluate system performance and joint mission effectiveness (Bjorkman and Gray 2009a). The LVC battlespace...attack (Bjorkman and Gray 2009b). Figure 3 - JTEM Methodology (Bjorkman 2008) A key INTEGRAL FIRE lesson learned was realizing the need for each
SOAR 89: Space Station. Space suit test program
NASA Technical Reports Server (NTRS)
Kosmo, Joseph J.; West, Philip; Rouen, Michael
1990-01-01
The elements of the test program for the space suit to be used on Space Station Freedom are noted in viewgraph form. Information is given on evaluation objectives, zero gravity evaluation, mobility evaluation, extravehicular activity task evaluation, and shoulder joint evaluation.
Wojczyńska, A; Leiggener, C S; Bredell, M; Ettlin, D A; Erni, S; Gallo, L M; Colombo, V
2016-10-01
The aim of this study was to qualitatively and quantitatively describe the biomechanics of existing total alloplastic reconstructions of temporomandibular joints (TMJ). Fifteen patients with unilateral or bilateral TMJ total joint replacements and 15 healthy controls were evaluated via dynamic stereometry technology. This non-invasive method combines three-dimensional imaging of the subject's anatomy with jaw tracking. It provides an insight into the patient's jaw joint movements in real time and provides a quantitative evaluation. The patients were also evaluated clinically for jaw opening, protrusive and laterotrusive movements, pain, interference with eating, and satisfaction with the joint replacements. The qualitative assessment revealed that condyles of bilateral total joint replacements displayed similar basic motion patterns to those of unilateral prostheses. Quantitatively, mandibular movements of artificial joints during opening, protrusion, and laterotrusion were all significantly shorter than those of controls. A significantly restricted mandibular range of motion in replaced joints was also observed clinically. Fifty-three percent of patients suffered from chronic pain at rest and 67% reported reduced chewing function. Nonetheless, patients declared a high level of satisfaction with the replacement. This study shows that in order to gain a comprehensive understanding of complex therapeutic measures, a multidisciplinary approach is needed. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
[A primary application and evaluation of temporomandibular joint replacement with stock prosthesis].
Zhang, Xiao-hu; Chen, Min-jie; Qiu, Ya-ting; Yang, Chi
2012-06-01
To evaluate the effect of total joint replacement in treatment of temporomandibular joint(TMJ) osteoarthropathy with stock prostheses. Six female patients involving 10 joints (2 unilateral and 4 bilateral), with an average age of 59 years old, were involved in this study. Three patients (5 joints) were diagnosed as internal derangement in V stage depending on MRI, 3D-CT findings and clinical characteristics. The other 3 patients (5 joints) had histories of failed temporomandibular joint operation using costochondral graft or temporalis fascial flap. The maximal mouth opening was 1.9 cm on average (range, 1.0 to 2.9cm). All the joints were replaced with Biomet standard prosthesis under general anesthesia. The follow-up period was from 7 to 49 months (average, 17.5 months). All the operations were successfully performed. Heterotopic ossification happened in a bilateral case 1 year postoperatively. One patient with bilateral joint disease complained of severe uncomfortable feeling in the region of the ears and the temples, although there was no significant positive signs according to an ENT examination. Pain relief of the joint and mouth opening improvement were significant in 4 patients. No failure was noted secondary to infection or loosening of the prostheses. The occlusal relationship kept stable postoperatively in all cases. Total TMJ joint replacement with standard prosthesis is a good choice for TMJ reconstruction. It can significantly reduce joint pain and the mouth opening limitation resulted from osteoarthritis. Long-term result remains to be evaluated based on a long-term follow-up.
Evaluation of Asphalt Bridge Deck Joint Systems.
DOT National Transportation Integrated Search
2009-12-01
Asphaltic Plug Joint is an expansion joint that is used for new and rehabilitated bridges. It provides a smooth and watertight surface free of debris; and offers simple, easy and staged construction. Asphaltic plug joint can be repaired segmentally a...
Evaluation of joint sealant materials : interim report No. 1.
DOT National Transportation Integrated Search
1972-03-01
This report illustrates some of the problems caused by ineffectively sealed joints and points to the great need for properly sealing joints in both concrete pavements and structures. : The principles of design including slab lengths, joint dimensions...
45 CFR 1355.35 - Program improvement plans.
Code of Federal Regulations, 2010 CFR
2010-10-01
... jointly by State and Federal staff in consultation with the review team; (ii) Identify the areas in which... be used to evaluate progress; (vi) Identify how the action steps in the plan build on and make... evaluated jointly by the State agency and ACF, in collaboration with other members of the review team, as...
Segmentation of hand radiographs using fast marching methods
NASA Astrophysics Data System (ADS)
Chen, Hong; Novak, Carol L.
2006-03-01
Rheumatoid Arthritis is one of the most common chronic diseases. Joint space width in hand radiographs is evaluated to assess joint damage in order to monitor progression of disease and response to treatment. Manual measurement of joint space width is time-consuming and highly prone to inter- and intra-observer variation. We propose a method for automatic extraction of finger bone boundaries using fast marching methods for quantitative evaluation of joint space width. The proposed algorithm includes two stages: location of hand joints followed by extraction of bone boundaries. By setting the propagation speed of the wave front as a function of image intensity values, the fast marching algorithm extracts the skeleton of the hands, in which each branch corresponds to a finger. The finger joint locations are then determined by using the image gradients along the skeletal branches. In order to extract bone boundaries at joints, the gradient magnitudes are utilized for setting the propagation speed, and the gradient phases are used for discriminating the boundaries of adjacent bones. The bone boundaries are detected by searching for the fastest paths from one side of each joint to the other side. Finally, joint space width is computed based on the extracted upper and lower bone boundaries. The algorithm was evaluated on a test set of 8 two-hand radiographs, including images from healthy patients and from patients suffering from arthritis, gout and psoriasis. Using our method, 97% of 208 joints were accurately located and 89% of 416 bone boundaries were correctly extracted.
Kim, Jeong Hwan; Gong, Hyun Sik; Kim, Youn Ho; Rhee, Seung Hwan; Kim, Jihyoung; Baek, Goo Hyun
2015-07-01
To determine whether median nerve dysfunction measured by electrophysiologic studies in carpal tunnel syndrome (CTS) is associated with thumb trapeziometacarpal (TMC) joint instability. We evaluated 71 women with CTS and 31 asymptomatic control women. Patients with generalized laxity or TMC joint osteoarthritis were excluded. We classified the electrophysiologic severity of CTS based on nerve conduction time and amplitude and assessed radiographic instability of the TMC joint based on TMC joint stress radiographs. We compared subluxation ratio between patients with CTS and controls and performed correlation analysis of the relationship between the electrophysiologic grade and subluxation ratio. Thirty-one patients were categorized into the mild CTS subgroup and 41 into the severe CTS subgroup. There was no significant difference in subluxation ratio between the control group and CTS patients or between the control group and CTS subgroup patients. Furthermore, there was no significant correlation between electrophysiologic grade and subluxation ratio. This study demonstrated that patients with CTS did not have greater radiographic TMC joint instability compared with controls, and suggests that TMC joint stability is not affected by impaired median nerve function. Further studies could investigate how to better evaluate proprioceptive function of TMC joint and whether other nerves have effects on TMC joint motor/proprioceptive function, to elucidate the relationship between neuromuscular control of the TMC joint, its stability, and its progression to osteoarthritis. Diagnostic II. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
A Comprehensive Histological Assessment of Osteoarthritis Lesions in Mice
McNulty, Margaret A.; Loeser, Richard F.; Davey, Cynthia; Callahan, Michael F.; Ferguson, Cristin M.; Carlson, Cathy S.
2011-01-01
Objective: Accurate histological assessment of osteoarthritis (OA) is critical in studies evaluating the effects of interventions on disease severity. The purpose of the present study was to develop a histological grading scheme that comprehensively and quantitatively assesses changes in multiple tissues that are associated with OA of the stifle joint in mice. Design: Two representative midcoronal sections from 158 stifle joints, including naturally occurring and surgically induced OA, were stained with H&E and Safranin-O stains. All slides were evaluated to characterize the changes present. A grading scheme that includes both measurements and semiquantitative scores was developed, and principal components analysis (PCA) was applied to the resulting data from the medial tibial plateaus. A subset of 30 tibial plateaus representing a wide range of severity was then evaluated by 4 observers. Reliability of the results was evaluated using intraclass correlation coefficients (ICCs) and area under the receiver operating characteristic (ROC) curve. Results: Five factors were retained by PCA, accounting for 74% of the total variance. Interobserver and intraobserver reproducibilities for evaluations of articular cartilage and subchondral bone were acceptable. The articular cartilage integrity and chondrocyte viability factor scores were able to distinguish severe OA from normal, minimal, mild, and moderate disease. Conclusion: This newly developed grading scheme and resulting factors characterize a range of joint changes in mouse stifle joints that are associated with OA. Overall, the newly developed scheme is reliable and reproducible, characterizes changes in multiple tissues, and provides comprehensive information regarding a specific site in the stifle joint. PMID:26069594
Giannotti, S; Giovannelli, D; Dell'Osso, G; Bottai, V; Bugelli, G; Celli, F; Citarelli, C; Guido, G
2016-04-01
The tibial plateau fractures involve one of the main weight bearing joints of the human body. The goals of surgical treatment are anatomical reduction, articular surface reconstruction and high primary stability. The aim of this study was to evaluate the clinical and functional outcomes after internal plate fixation of this kind of fractures. From January 2009 to December 2012, we treated 75 cases of tibial plateau fracture with angular stable plates. We used Rasmussen Score and the Knee Society Score for the clinical and functional evaluation. Twenty-five cases that underwent hardware removal had arthroscopic and CT evaluation of the joint. No complications occurred. The clinical and functional evaluation, performed by the KSS and Rasmussen Score, highlighted the high percentage of good-to-excellent results (over 90 %). In every case, the range of motion was good with flexion >90°. Arthroscopy showed the presence of chondral damage in 100 % of patients. In all the cases, we found that X-ray images seem better than the CT images. Angular stable plates allow to obtain a good primary stability, permitting an early joint recovery with an excellent range of motion. Avoiding to perform a knee arthrotomy at the time of fracture reduction could prove to be an advantage in terms of functional recovery. The meniscus on the injured bone should be preserved in order to maintain good function of the joint. X-ray images remain the gold standard in checking the progression of post-traumatic osteoarthritis.
Gruen, Margaret E.; Messenger, Kristen M.; Thomson, Andrea E.; Griffith, Emily H.; Aldrich, Lauren A.; Vaden, Shelly; Lascelles, BDX
2017-01-01
Degenerative joint disease is common in cats, with signs of pain frequently found on orthopedic examination and radiographs often showing evidence of disease. However, understanding of the pathophysiology of degenerative joint disease and associated pain remains limited. Several cytokines have been identified as having a role in pain in humans, but this has not been investigated in cats. The present study was performed to use a multiplex platform to evaluate the concentration of 19 cytokines and chemokines in serum samples obtained from cats with and without degenerative joint disease and associated pain. Samples from a total of 186 cats were analyzed, with cats representing a range of severity on radiographic and orthopedic evaluations and categorized by degenerative joint disease scores and pain scores. Results showed that cats with higher radiographic degenerative joint disease scores have higher serum concentrations of IL-4 and IL-8, while cats with higher orthopedic exam pain scores have higher concentrations of IL-8, IL-2, and TNF-α increased concentration of IL-8 in degenerative joint disease and pain may be confounded by the association with age. Discriminant analysis was unable to identify one or more cytokines that distinguish between groups of cats classified based on degenerative joint disease score category or pain score category. Finally, cluster analysis driven by analyte concentrations show separation of groups of cats, but features defining the groups remain unknown. Further studies are warranted to investigate any changes in cytokine concentrations in response to analgesic therapies, and further evaluate the elevations in cytokine concentrations found here, particularly focused on studies of local cytokines present in synovial fluid. PMID:28063477
1985-08-01
Class high - speed containerships and their subsequent conversion to a cargo configuration specifically designed for rapid load-offload of military unit...Rough Terrain Forklift SLWT Side-Loadable Warping Tug ST Short Ton STON Short Ton SUROB Surf Observations T-ACS Auxiliary Crane Ship T- AKR Auxiliary Cargo ...their delivery systems for container, breakbulk, and bulk liquid cargo , and to define the operating performance of the combined systems in a joint test
Evaluation of Rock Joint Coefficients
NASA Astrophysics Data System (ADS)
Audy, Ondřej; Ficker, Tomáš
2017-10-01
A computer method for evaluation of rock joint coefficients is described and several applications are presented. The method is based on two absolute numerical indicators that are formed by means of the Fourier replicas of rock joint profiles. The first indicator quantifies the vertical depth of profiles and the second indicator classifies wavy character of profiles. The absolute indicators have replaced the formerly used relative indicators that showed some artificial behavior in some cases. This contribution is focused on practical computations testing the functionality of the newly introduced indicators.
Design and evaluation of a modular lower limb exoskeleton for rehabilitation.
Dos Santos, Wilian M; Nogueira, Samuel L; de Oliveira, Gustavo C; Pena, Guido G; Siqueira, Adriano A G
2017-07-01
This paper deals with the evaluation of an exoskeleton designed for assisting individuals to rehabilitate compromised lower limb movements resulting from stroke or incomplete spinal cord injury. The exoskeleton is composed of lightweight tubular structures and six free joints that provide a modular feature to the system. This feature allows the exoskeleton to be adapted to assist the movement of one or more patient joints. The actuation of the exoskeleton is also modular, and can be performed passively, by means of springs and dampers, or actively through actuators. In addition, its telescopic tubular links, developed to adjust the size of the links in order to align the joints of the exoskeleton with patient joints, allows the exoskeleton to be adjustable to fit different patients. Experiments considering the interaction between a healthy subject and the exoskeleton are performed to evaluate the influence of the exoskeleton structure on kinematic and muscular activity profiles during walking.
ICG-enhanced imaging of arthritis with an integrated Optical Imaging/X-ray System
Meier, Reinhard; Krug, Christian; Golovko, Daniel; Boddington, Sophie; Piontek, Guido; Rudelius, Martina; Sutton, Elizabeth J.; Baur-Melnyk, Andrea; Jones, Ella F.; Daldrup-Link, Heike E.
2010-01-01
Background Optical Imaging (OI) is a promising technique that is quick, inexpensive and, in combination with Indocyanine Green (ICG), an FDA-approved fluorescent dye, could provide early detection of rheumatoid arthritis. Objective The purpose of this study was to evaluate a combined X-ray/OI imaging system for ICG-enhanced detection of arthritic joints in a rat model of antigen induced arthritis. Methods Arthritis of the knee and ankle joints was induced in six Harlan rats with peptidoglycan polysaccharide polymers (PGPS). Three rats served as non-treated controls. Optical imaging of the knee and ankle joints was done with an integrated OI/X-ray system before and up to 24h post intravenous injection (p.i.) of 10mg/kg ICG. The fluorescence signal intensities of arthritic and normal joints were compared for significant differences using generalized estimation equation models. Specimen of knee and ankle joints were further processed and evaluated by histology. Results ICG provided a significant increase in fluorescence signal of arthritic joints compared to baseline values immediately after administration (p<0.05). The fluorescence signal of arthritic joints was significantly higher compared to the non-arthritic control joints at 1 - 720 min p.i. (p<0.05). Fusion of ICG-enhanced OI and X-rays allowed for anatomical co-registration of the inflamed tissue with the associated joint. H&E stains confirmed marked synovial inflammation of arthritic joints and absence of inflammation in control joints. Conclusion ICG-enhanced OI is a clinically applicable tool for detection of arthritic tissue. Using relatively high doses of ICG, a long term fluorescence enhancement of arthritic joints can be achieved. This may facilitate simultaneous evaluations of multiple joints in a clinical setting. Fusion of ICG-OI scans with X-ray imaging increases anatomical resolution. PMID:20506388
Ley, C J; Björnsdóttir, S; Ekman, S; Boyde, A; Hansson, K
2016-01-01
Validated noninvasive detection methods for early osteoarthritis (OA) are required for OA prevention and early intervention treatment strategies. To evaluate radiography and low-field magnetic resonance imaging (MRI) for the detection of early stage OA osteochondral lesions in equine centrodistal joints using microscopy as the reference standard. Prospective imaging of live horses and imaging and microscopy of cadaver tarsal joints. Centrodistal (distal intertarsal) joints of 38 Icelandic research horses aged 27-29 months were radiographed. Horses were subjected to euthanasia approximately 2 months later and cadaver joints examined with low-field MRI. Osteochondral joint specimens were classified as negative or positive for OA using light microscopy histology or scanning electron microscopy. Radiographs and MRIs were evaluated for osteochondral lesions and results compared with microscopy. Forty-two joints were classified OA positive with microscopy. Associations were detected between microscopic OA and the radiography lesion categories; mineralisation front defect (P<0.0001), joint margin lesion (P<0.0001), central osteophyte (P = 0.03) and the low-field MRI lesion categories; mineralisation front defect (P = 0.01), joint margin lesion (P = 0.02) and articular cartilage lesion (P = 0.0003). The most frequent lesion category detected in microscopic OA positive joints was the mineralisation front defect in radiographs (28/42 OA positive joints, specificity 97%, sensitivity 67%). No significant differences were detected between the sensitivity and specificity of radiography and low-field MRI pooled lesion categories, but radiography was often superior when individual lesion categories were compared. Early stage centrodistal joint OA changes may be detected with radiography and low-field MRI. Detection of mineralisation front defects in radiographs may be a useful screening method for detection of early OA in centrodistal joints of young Icelandic horses. © 2015 EVJ Ltd.
Saltzherr, Michael S; Coert, J Henk; Selles, Ruud W; van Neck, Johan W; Jaquet, Jean-Bart; van Osch, Gerjo J V M; Oei, Edwin H G; Luime, Jolanda J; Muradin, Galied S R
2017-03-14
Magnetic resonance imaging (MRI) is increasingly used for research in hand osteoarthritis, but imaging the thin cartilage layers in the hand joints remains challenging. We therefore assessed the accuracy of MRI in detecting cartilage loss in patients with symptomatic osteoarthritis of the first carpometacarpal (CMC1) joint. Twelve patients scheduled for trapeziectomy to treat severe symptomatic osteoarthritis of the CMC1 joint underwent a preoperative high resolution 3D spoiled gradient (SPGR) MRI scan. Subsequently, the resected trapezium was evaluated histologically. The sections were scored for cartilage damage severity (Osteoarthritis Research Society International (OARSI) score), and extent of damage (percentage surface area). Each MRI scan was scored for the area of normal cartilage, partial cartilage loss and full cartilage loss. The percentages of the total surface area with any cartilage loss and full-thickness cartilage loss were calculated using MRI and histological evaluation. MRI and histological evaluation both identified large areas of overall cartilage loss. The median (IQR) surface area of any cartilage loss on MRI was 98% (82-100%), and on histological assessment 96% (87-98%). However, MRI underestimated the extent of full-thickness cartilage loss. The median (IQR) surface area of full-thickness cartilage loss on MRI was 43% (22-70%), and on histological evaluation 79% (67-85%). The difference was caused by a thin layer of high signal on the articulating surface, which was interpreted as damaged cartilage on MRI but which was not identified on histological evaluation. Three-dimensional SPGR MRI of the CMC1 joint demonstrates overall cartilage damage, but underestimates full-thickness cartilage loss in patients with advanced osteoarthritis.
Effect of Shielding Gas on the Properties of AW 5083 Aluminum Alloy Laser Weld Joints
NASA Astrophysics Data System (ADS)
Vyskoč, Maroš; Sahul, Miroslav; Sahul, Martin
2018-04-01
The paper deals with the evaluation of the shielding gas influence on the properties of AW 5083 aluminum alloy weld joints produced with disk laser. Butt weld joints were produced under different shielding gas types, namely Ar, He, Ar + 5 vol.% He, Ar + 30 vol.% He and without shielding weld pool. Light and electron microscopy, computed tomography, microhardness measurements and tensile testing were used for evaluation of weld joint properties. He-shielded weld joints were the narrowest ones. On the other hand, Ar-shielded weld joints exhibited largest weld width. The choice of shielding gas had significant influence on the porosity level of welds. The lowest porosity was observed in weld joint produced in Ar with the addition of 5 vol.% He shielding atmosphere (only 0.03%), while the highest level of porosity was detected in weld joint produced in pure He (0.24%). Except unshielded aluminum alloy weld joint, the lowest tensile strength was recorded in He-shielded weld joints. On the contrary, the highest average microhardness was measured in He-shielded weld joints.
NASA Technical Reports Server (NTRS)
1981-01-01
The development of several types of graphite/polyimide (GR/PI) bonded and bolted joints is reported. The program consists of two concurrent tasks: (1) design and test of specific built up attachments; and (2) evaluation of standard advanced bonded joint concepts. A data base for the design and analysis of advanced composite joints for use at elevated temperatures (561K (550 deg F)) to design concepts for specific joining applications, and the fundamental parameters controlling the static strength characteristics of such joints are evaluated. Data for design and build GR/PI of lightly loaded flight components for advanced space transportation systems and high speed aircraft are presented. Results for compression and interlaminar shear strengths of Celion 6000/PMR-15 laminates are given. Static discriminator test results for type 3 and type 4 bonded and bolted joints and final joint designs for TASK 1.4 scale up fabrication and testing are presented.
Apprentice Performance Evaluation.
ERIC Educational Resources Information Center
Gast, Clyde W.
The Granite City (Illinois) Steel apprentices are under a performance evaluation from entry to graduation. Federally approved, the program is guided by joint apprenticeship committees whose monthly meetings include performance evaluation from three information sources: journeymen, supervisors, and instructors. Journeymen's evaluations are made…
Joint Aspiration (Arthrocentesis)
... arthritis, or JRA), systemic lupus erythematosus (SLE), and Lyme disease. Joint aspiration is diagnostic but it also can ... topic for: Parents Kids Teens Evaluate Your Child's Lyme Disease Risk Living With Lupus Bones, Muscles, and Joints ...
Continuously reinforced concrete pavement inventory
NASA Astrophysics Data System (ADS)
Halverson, A. D.; Hagen, M. G.
1982-09-01
A typical concrete pavement has expansion and contraction joints across and along the pavement surface. The joints allow the pavement to change in dimension with changes in temperature. A continuously reinforced concrete pavement (CRCP) does not have expansion or contraction joints. Random, closely spaced cracks are expected to develop naturally and allow for expansion and contraction due to temperature changes. The many random cracks eliminate expensive joint maintenance. This maintenance-free service life feature has not occurred in Minnesota. This CRCP inventory is a physical evaluation of the extent of corrosion on random sections of pavement. It is related to concurrent efforts which will evaluate CRCP rehabilitation techniques.
Lobet, S; Detrembleur, C; Francq, B; Hermans, C
2010-09-01
A major complication in haemophilia is the destruction of joint cartilage because of recurrent intraarticular and intramuscular bleeds. Therefore, joint assessment is critical to quantify the extent of joint damage, which has traditionally been evaluated using both radiological and clinical joint scores. Our study aimed to evaluate the natural progression of haemophilic arthopathy using three-dimensional gait analysis (3DGA) and to assess the reproducibility of this technique. We hypothesized that the musculoskeletal function was relatively stable in patients with haemophilia. Eighteen adults with established haemophilic arthropathies were evaluated twice by 3DGA (mean follow-up: 18 +/- 5 weeks). Unexpectedly, our findings revealed infraclinical deterioration of gait pattern, characterized by a 3.2% decrease in the recovery index, which is indicative of the subject's ability to save energy while walking. A tendency towards modification of segmental joint function was also observed. Gait analysis was sufficiently reproducible with regards to spatiotemporal parameters as well as kinetic, mechanical and energetic gait variables. The kinematic variables were reproducible in both the sagittal and frontal planes. In conclusion, 3DGA is a reproducible tool to assess abnormal gait patterns and monitor natural disease progression in haemophilic patients.
2006-08-10
NASA's F-15B testbed aircraft in flight during the first evaluation flight of the joint NASA/Gulfstream Quiet Spike project. The project seeks to verify the structural integrity of the multi-segmented, articulating spike attachment designed to reduce and control a sonic boom.
Automated inspection of solder joints for surface mount technology
NASA Technical Reports Server (NTRS)
Savage, Robert M.; Park, Hyun Soo; Fan, Mark S.
1993-01-01
Researchers at NASA/GSFC evaluated various automated inspection systems (AIS) technologies using test boards with known defects in surface mount solder joints. These boards were complex and included almost every type of surface mount device typical of critical assemblies used for space flight applications: X-ray radiography; X-ray laminography; Ultrasonic Imaging; Optical Imaging; Laser Imaging; and Infrared Inspection. Vendors, representative of the different technologies, inspected the test boards with their particular machine. The results of the evaluation showed limitations of AIS. Furthermore, none of the AIS technologies evaluated proved to meet all of the inspection criteria for use in high-reliability applications. It was found that certain inspection systems could supplement but not replace manual inspection for low-volume, high-reliability, surface mount solder joints.
Kobayashi, Naomi; Inaba, Yutaka; Tateishi, Ukihide; Yukizawa, Yohei; Ike, Hiroyuki; Inoue, Tomio; Saito, Tomoyuki
2013-10-01
Recent studies have reported the acceleration of subchondral bone remodeling during the development of osteoarthritis (OA). However, it is not possible to evaluate such molecular abnormalities using conventional radiographic techniques. We have applied 18F-fluoride PET to the analysis of painful or dysplastic hips at various stages of OA and then compared this with radiographic findings and clinical findings. A consecutive series of 65 joints from 48 patients (average age, 40 years; range, 19-72 years) with a hip joint complaint or radiographic dysplastic hip were enrolled in this study. Twenty-five contralateral joints without any evidence of OA or clinical symptoms were assigned as a normal control group. Radiographic evaluations were performed on the basis of Kellgren and Lawrence grade and the minimum joint space. Clinical evaluations were performed using the grading scale for pain severity and the SUVmax was measured for each joint. The association between SUVmax and the radiographic or clinical findings was evaluated. 18F-fluoride PET shows a significantly higher uptake value for progressive-stage OA cases than for early-stage cases and also shows a significantly higher uptake value in cases with severe pain. Even in early-OA-stage patients who do not show joint space narrowing on a plain x-ray, cases with severe pain show a significantly higher uptake value. 18F-fluoride PET has great potential as an imaging method for diagnosing early-stage OA without any marked radiographic changes.
Clinical Evaluation of the TITAN™ Total Shoulder System
2018-02-14
Arthritis; Arthritis, Degenerative; Rheumatoid Arthritis; Post-traumatic Arthrosis of Other Joints, Shoulder Region; Rotator Cuff Syndrome of Shoulder and Allied Disorders; Fracture; Avascular Necrosis; Joint Instability; Joint Trauma; Dislocation, Shoulder; Pain, Shoulder
Improving agreement in assessment of synovitis in rheumatoid arthritis.
Cheung, Peter P; Dougados, Maxime; Andre, Vincent; Balandraud, Nathalie; Chales, Gérard; Chary-Valckenaere, Isabelle; Chatelus, Emmanuel; Dernis, Emmanuelle; Gill, Ghislaine; Gilson, Mélanie; Guis, Sandrine; Mouterde, Gael; Pavy, Stephan; Pouyol, François; Marhadour, Thierry; Richette, Pascal; Ruyssen-Witrand, Adeline; Soubrier, Martin; Gossec, Laure
2013-03-01
Synovitis assessment through evaluation of swollen joints is integral in steering treatment decisions in rheumatoid arthritis (RA). However, there is high inter-observer variation. The objective was to assess if a short collegiate consensus would improve swollen joint agreement between rheumatologists and whether this was affected by experience. Eighteen rheumatologists from French university rheumatology units participated in three 30 minutes rounds over a half day meeting evaluating joint counts of RA patients in small groups, followed by short consensus discussions. Agreement was evaluated at the end of each round as follows: (i) global agreement of swollen joints (ii) swollen joint agreement according to level of experience of the rheumatologist (iii) swollen joint count and (iv) agreement of disease activity state according to the Disease Activity Score (DAS28). Agreement was calculated using percentage agreement and kappa. Global agreement of swollen joints failed to improve (kappa 0.50 to 0.52) at the joint level. Agreement between seniors did not improve but agreement between newly qualified rheumatologists and their senior peer, which was initially poor (kappa 0.28), improved significantly (to 0.54) at the end of the consensus exercises. Concordance of DAS28 activity states improved from 71% to 87%. Consensus exercises for swollen joint assessment is worthwhile and may potentially improve agreement between clinicians in clinical synovitis and disease activity state, benefit was mostly observed in newly qualified rheumatologists. Copyright © 2012 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.
Modification and Adaptation of the Program Evaluation Standards in Saudi Arabia
ERIC Educational Resources Information Center
Alyami, Mohammed
2013-01-01
The Joint Committee on Standards for Educational Evaluation's Program Evaluation Standards is probably the most recognized and applied set of evaluation standards globally. The most recent edition of The Program Evaluation Standards includes five categories and 30 standards. The five categories are Utility, Feasibility, Propriety, Accuracy, and…
Evaluation of the finite element software ABAQUS for biomechanical modelling of biphasic tissues.
Wu, J Z; Herzog, W; Epstein, M
1998-02-01
The biphasic cartilage model proposed by Mow et al. (1980) has proven successful to capture the essential mechanical features of articular cartilage. In order to analyse the joint contact mechanics in real, anatomical joints, the cartilage model needs to be implemented into a suitable finite element code to approximate the irregular surface geometries of such joints. However, systematic and extensive evaluation of the capacity of commercial software for modelling the contact mechanics with biphasic cartilage layers has not been made. This research was aimed at evaluating the commercial finite element software ABAQUS for analysing biphasic soft tissues. The solutions obtained using ABAQUS were compared with those obtained using other finite element models and analytical solutions for three numerical tests: an unconfined indentation test, a test with the contact of a spherical cartilage surface with a rigid plate, and an axi-symmetric joint contact test. It was concluded that the biphasic cartilage model can be implemented into the commercial finite element software ABAQUS to analyse practical joint contact problems with biphasic articular cartilage layers.
NASA Technical Reports Server (NTRS)
Slater, Richard
1996-01-01
A joint U.S./Russian film test was conducted during MIR Mission 18 to evaluate the effects of radiation on photographic film during long-duration space flights. Two duplicate sets of film were flown on this MIR mission: one set was processed and evaluated by the NASA/JSC Photographic Laboratory, and the other by the RKK Energia's Photographic Laboratory in Moscow. This preliminary report includes only the results of the JSC evaluation (excluding the SN-10 film which was not available for evaluation at the time this report was written). The final report will include an evaluation by JSC of the SN-10 film and an evaluation of the test data by the RKK Energia. ISC's evaluation of the test data showed the positive film flown was damaged very little when exposed to approximately 8 rads of radiation. Two of the three negative films were significantly damaged and the third film was damaged only moderately.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slater, R.
1996-04-01
A joint U.S./Russian film test was conducted during MIR Mission 18 to evaluate the effects of radiation on photographic film during long-duration space flights. Two duplicate sets of film were flown on this MIR mission: one set was processed and evaluated by the NASA/JSC Photographic Laboratory, and the other by the RKK Energia`s Photographic Laboratory in Moscow. This preliminary report includes only the results of the JSC evaluation (excluding the SN-10 film which was not available for evaluation at the time this report was written). The final report will include an evaluation by JSC of the SN-10 film and anmore » evaluation of the test data by the RKK Energia. ISC`s evaluation of the test data showed the positive film flown was damaged very little when exposed to approximately 8 rads of radiation. Two of the three negative films were significantly damaged and the third film was damaged only moderately.« less
Lu, Wei; Wang, Lin; Yao, Jing; Wo, Chunxin; Chen, Yu
2018-06-22
Degenerative alterations in articular cartilage are involved in the pathogenesis of osteoarthritis. The present study aimed to evaluate the role of complement component 5a (C5a) in osteoarthritic alterations in the articular cartilage and synovialis via a joint immobilization (IM) rat model. Rats were assigned to three groups: Control, IM and IM+anti‑C5a antibody (IM+anti‑C5a) groups. A terminal deoxynucleotidyl transferase dUTP nick end labeling assay and hematoxylin and eosin staining were used to evaluate the morphological alterations in the articular cartilage and synovialis. Reverse transcription‑quantitative polymerase chain reaction (RT‑qPCR) analysis, immunohistochemical analysis and western blotting were used to evaluate C5a expression in the articular cartilage and synovialis. An ELISA was used to evaluate C5a‑induced alterations in interleukin (IL)‑1β, IL‑17A and tumor necrosis factor (TNF)‑α levels in the serum and joint fluid. The results demonstrated that knee joint immobilization induced destruction of knee joint synovial fluid and cartilage in the IM and IM+anti‑C5a antibody groups. Immobilization significantly increased the expression levels of C5a in serum and joint fluid in the IM group. Immunohistochemistry, western blotting and RT‑qPCR analysis illustrated markedly increased expression of C5a in the IM group. Immobilization markedly increased the IL‑1β, IL‑17A and TNF‑α expression levels in the serum and joint fluid in the IM group. Anti‑C5a was able to decrease immobilization‑induced alterations in morphology and cytokines compared with the IM group. The expression of C5a was increased in synoviocytes and joint cartilage in the IM model. Pro‑inflammatory cytokines, including TNF‑α and IL‑1β were released in the activated synoviocytes via the induction of C5a, suggesting that C5a serves an important role in joint inflammatory processes.
Bonin, Glen; Lauer, Susanne K; Guzman, David Sanchez-Migallon; Nevarez, Javier; Tully, Thomas N; Hosgood, Giselle; Gaschen, Lorrie
2009-06-01
Information on perching-joint angles in birds is limited. Joint immobilization in a physiologic perching angle has the potential to result more often in complete restoration of limb function. We evaluated perching-joint angles in 10 healthy cockatiels (Nymphicus hollandicus), 10 Hispaniolan Amazons (Amazona ventralis), and 9 barred owls (Strix varia) and determined intra- and interobserver variability for goniometric measurements in 2 different radiographic projections. Intra- and interobserver variation was less than 7% for all stifle and intertarsal joint measurements but frequently exceeded 10% for the hip-joint measurements. Hip, stifle, and intertarsal perching angles differed significantly among cockatiels, Hispaniolan Amazon parrots, and barred owls. The accuracy of measurements performed on straight lateral radiographic projections with superimposed limbs was not consistently superior to measurements on oblique projections with a slightly rotated pelvis. Stifle and intertarsal joint angles can be measured on radiographs by different observers with acceptable variability, but intra- and interobserver variability for hip-joint-angle measurements is higher.
Hu, Chunying; Huang, Qiuchen; Yu, Lili; Hu, Yue; Rongming, Xia; Li, Zhou; Xiaojiao, Fu; Gu, Rui; Cui, Yao; Ge, Meng; Xu, Yanfeng; Liu, Jianfeng
2016-05-01
[Purpose] The purpose of this study was to examine immediate effects of strength training and NJF distal resistance training in wrist joints by using writing time and evaluation of proprioception using the JPE test. [Subjects and Methods] The subjects were 12 young healthy people (24.2 ± 3.1 y, 169.7 ± 6.5 cm, 65.3 ± 12.6 kg). Two isotonic contraction techniques were applied on the wrist joint: wrist joint extension muscle strength training (MST) and the wrist joint extension pattern of NJF. The uppercase English alphabet writing time and joint position errors of the left upper limb were measured before and after one intervention session of MST and NJF. [Results] The decrease in errors in wrist extension angle repetition and the writing time represented the improvement resulting from NJF. [Conclusion] This result suggests that the subdominant hands wrist joint proprioception and writing function can be improved by NJF together with proximal resistance training.
Purevsuren, Tserenchimed; Batbaatar, Myagmarbayar; Khuyagbaatar, Batbayar; Kim, Kyungsoo; Kim, Yoon Hyuk
2018-03-12
Biomechanical studies have indicated that the conventional non-anatomic reconstruction techniques for lateral ankle sprain (LAS) tend to restrict subtalar joint motion compared to intact ankle joints. Excessive restriction in subtalar motion may lead to chronic pain, functional difficulties, and development of osteoarthritis. Therefore, various anatomic surgical techniques to reconstruct both the anterior talofibular and calcaneofibular ligaments have been introduced. In this study, ankle joint stability was evaluated using multibody computational ankle joint model to assess two new anatomic reconstruction and three popular non-anatomic reconstruction techniques. An LAS injury, three popular non-anatomic reconstruction models (Watson-Jones, Evans, and Chrisman-Snook), and two common types of anatomic reconstruction models were developed based on the intact ankle model. The stability of ankle in both talocrural and subtalar joint were evaluated under anterior drawer test (150 N anterior force), inversion test (3 Nm inversion moment), internal rotational test (3 Nm internal rotation moment), and the combined loading test (9 Nm inversion and internal moment as well as 1800 N compressive force). Our overall results show that the two anatomic reconstruction techniques were superior to the non-anatomic reconstruction techniques in stabilizing both talocrural and subtalar joints. Restricted subtalar joint motion, which mainly observed in Watson-Jones and Chrisman-Snook techniques, was not shown in the anatomical reconstructions. Evans technique was beneficial for subtalar joint as it does not restrict subtalar motion, though Evans technique was insufficient for restoring talocrural joint inversion. The anatomical reconstruction techniques best recovered ankle stability.
What role do plain radiographs have in assessing the skeletally immature acromioclavicular joint?
Lee, Seung Yeol; Kwon, Soon-Sun; Chung, Chin Youb; Lee, Kyoung Min; Park, Moon Seok
2014-01-01
Because of incomplete ossification of the coracoid process and acromion, acromioclavicular joint configuration in the skeletally immature patient differs from that of adults. Although comparison to radiographic standards for this joint is critical in the evaluation of acromioclavicular joint injuries, these standards are not well defined for children or adolescents. We therefore sought to determine (1) the reliability of numerous radiographic measurements of the skeletally immature acromioclavicular joint, including the vertical and shortest coracoclavicular interval, and the acromioclavicular joint offset; (2) the timing of ossification of the acromion and coracoid in males and females; and (3) the differences in the values of these radiographic measurements based on age and sex. This study was based on a total of 485 subjects, 8 to 18 years old, who underwent conventional AP view radiographs of both shoulders. The 485 subjects were included to assess normal configuration around the acromioclavicular joint and 466 of these subjects were evaluated for comparison between both sides. The vertical and shortest coracoclavicular interval, coracoclavicular clavicle width ratio, acromioclavicular joint offset, and difference of the coracoclavicular interval of both sides were measured. A reliability test was conducted before obtaining the main measurements. The relationship of measurements with sex, age, and stage of ossification was evaluated. The vertical and shortest coracoclavicular interval showed excellent reliability (intraclass correlation coefficient ([ICC], 0.918 and 0.934). The acromioclavicular joint offset showed low reliability (ICC, 0.543). The ossification centers of the acromion and the coracoid processes appeared and fused earlier in females than in males. The vertical coracoclavicular interval, which was not affected by partial ossification of the coracoid process, was less than 11 mm in the 90% quantile of total subjects in males and 10 mm in the 90% quantile in females. The difference of the vertical coracoclavicular interval of both sides was less than 50% in 436 of 466 (93.4%) patients. The vertical coracoclavicular interval was the best parameter to assess acromioclavicular joint dislocation in skeletally immature patients. Comparison of both sides of the acromioclavicular joint could help to inform physicians in predicting the need for additional evaluations.
Thermal imaging in screening of joint inflammation and rheumatoid arthritis in children.
Lasanen, R; Piippo-Savolainen, E; Remes-Pakarinen, T; Kröger, L; Heikkilä, A; Julkunen, P; Karhu, J; Töyräs, J
2015-02-01
Potential of modern thermal imaging for screening and differentiation of joint inflammation has not been assessed in child and juvenile patient populations, typically demanding groups in diagnostics of musculoskeletal disorders. We hypothesize that thermal imaging can detect joint inflammation in patients with juvenile idiopathic arthritis or autoimmune disease with arthritis such as systemic lupus erythematosus. To evaluate the hypothesis, we studied 58 children exhibiting symptoms of joint inflammation. First, the patients' joints were examined along clinical procedure supplemented with ultrasound imaging when deemed necessary by the clinician. Second, thermal images were acquired from patients' knees and ankles. Results of thermal imaging were compared to clinical evaluations in knee and ankle. The temperatures were significantly (pmax = 0.044, pmean < 0.001) higher in inflamed ankle joints, but not in inflamed knee joints. No significant difference was found between the skin surface temperatures of medial and lateral aspects of ankle joints. In knee joints the mean temperatures of medial and lateral aspect differed significantly (p = 0.004). We have demonstrated that thermal imaging may have potential for detecting joint inflammation in ankle joints of children. For knee joints our results are inconclusive and further research is warranted.
DOT National Transportation Integrated Search
2006-03-01
Maine highways have been showing signs of longitudinal joint failure for a number of years. In an effort : to reduce the amount of joint failures the Maine Department of Transportation (MDOT) is currently : evaluating two projects. One project is mon...
ERIC Educational Resources Information Center
Cejas, Ivette; Barker, David H.; Quittner, Alexandra L.; Niparko, John K.
2014-01-01
Purpose: To evaluate joint engagement (JE) in age-matched children with and without hearing and its relationship to oral language skills. Method: Participants were 180 children with severe-to-profound hearing loss prior to cochlear implant surgery, and 96 age-matched children with normal hearing; all parents were hearing. JE was evaluated in a…
Jeff Kline; Mark E. Harmon; Thomas A. Spies; Anita T. Morzillo; Robert J. Pabst; Brenda C. McComb; Frank Schnekenburger; Keith A. Olsen; Blair Csuti; Jody C. Vogeler
2016-01-01
Forest policymakers and managers have long sought ways to evaluate the capability of forest landscapes to jointly produce timber, habitat, and other ecosystem services in response to forest management. Currently, carbon is of particular interest as policies for increasing carbon storage on federal lands are being proposed. However, a challenge in joint production...
A Note on the Purposes, Development, and Applicability of the Joint Committee Evaluation Standards
ERIC Educational Resources Information Center
Stufflebeam, Daniel L.
2004-01-01
The past few years have seen efforts in several countries and a wide range of disciplines to adopt and apply existing professional standards for guiding and judging evaluation services and/or develop new standards. Some of the efforts have drawn from the work and products of the North American Joint Committee on Standards for Educational…
Radiation dose in temporomandibular joint zonography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coucke, M.E.; Bourgoignie, R.R.; Dermaut, L.R.
1991-06-01
Temporomandibular joint morphology and function can be evaluated by panoramic zonography. Thermoluminescent dosimetry was applied to evaluate the radiation dose to predetermined sites on a phantom eye, thyroid, pituitary, and parotid, and the dose distribution on the skin of the head and neck when the TMJ program of the Zonarc panoramic x-ray unit was used. Findings are discussed with reference to similar radiographic techniques.
Operating Comfort Prediction Model of Human-Machine Interface Layout for Cabin Based on GEP.
Deng, Li; Wang, Guohua; Chen, Bo
2015-01-01
In view of the evaluation and decision-making problem of human-machine interface layout design for cabin, the operating comfort prediction model is proposed based on GEP (Gene Expression Programming), using operating comfort to evaluate layout scheme. Through joint angles to describe operating posture of upper limb, the joint angles are taken as independent variables to establish the comfort model of operating posture. Factor analysis is adopted to decrease the variable dimension; the model's input variables are reduced from 16 joint angles to 4 comfort impact factors, and the output variable is operating comfort score. The Chinese virtual human body model is built by CATIA software, which will be used to simulate and evaluate the operators' operating comfort. With 22 groups of evaluation data as training sample and validation sample, GEP algorithm is used to obtain the best fitting function between the joint angles and the operating comfort; then, operating comfort can be predicted quantitatively. The operating comfort prediction result of human-machine interface layout of driller control room shows that operating comfort prediction model based on GEP is fast and efficient, it has good prediction effect, and it can improve the design efficiency.
Operating Comfort Prediction Model of Human-Machine Interface Layout for Cabin Based on GEP
Wang, Guohua; Chen, Bo
2015-01-01
In view of the evaluation and decision-making problem of human-machine interface layout design for cabin, the operating comfort prediction model is proposed based on GEP (Gene Expression Programming), using operating comfort to evaluate layout scheme. Through joint angles to describe operating posture of upper limb, the joint angles are taken as independent variables to establish the comfort model of operating posture. Factor analysis is adopted to decrease the variable dimension; the model's input variables are reduced from 16 joint angles to 4 comfort impact factors, and the output variable is operating comfort score. The Chinese virtual human body model is built by CATIA software, which will be used to simulate and evaluate the operators' operating comfort. With 22 groups of evaluation data as training sample and validation sample, GEP algorithm is used to obtain the best fitting function between the joint angles and the operating comfort; then, operating comfort can be predicted quantitatively. The operating comfort prediction result of human-machine interface layout of driller control room shows that operating comfort prediction model based on GEP is fast and efficient, it has good prediction effect, and it can improve the design efficiency. PMID:26448740
Scharf, V F; Lewis, S T; Wellehan, J F; Wamsley, H L; Richardson, R; Sundstrom, D A; Lewis, D D
2015-06-01
To evaluate the efficacy of synovial fluid culture in obtaining the causative organism from dogs with suspected septic arthritis. In this retrospective evaluation, synovial fluid cytology and microbiology submissions from dogs with suspected septic arthritis from March 2007 to August 2011 were reviewed. Synovial fluid cytology consistent with joint sepsis was identified. Cultures of synovial fluid from dogs with clinical histories and abnormalities consistent with septic arthritis were used to evaluate the efficacy of bacterial isolation. In total, 36 dogs met the inclusion criteria. Initial aerobic cultures of joint fluid yielded bacterial growth in 44% of these dogs. All anaerobic cultures were negative. In 19% of the dogs with positive cultures, antibiotics had been administered prior to arthrocentesis compared with 10% of dogs with negative cultures. There was no association between culture efficacy and the administration of antimicrobial treatment prior to synovial fluid culture or recent surgery involving the affected joint (P=0.637 and P=0.106, respectively). Culture of synovial fluid from dogs with suspected septic arthritis has a low yield, necessitating a more effective means of identifying bacteria from suspected septic joints in dogs. © 2015 Australian Veterinary Association.
Krohn, Michaela; Ohrndorf, Sarah; Werner, Stephanie G; Schicke, Bernd; Burmester, Gerd-Rüdiger; Hamm, Bernd; Backhaus, Marina; Hermann, Kay-Geert A
2015-07-01
Near-infrared fluorescence optical imaging (FOI) is a novel imaging technology in the detection and evaluation of different arthritides. FOI was validated in comparison to magnetic resonance imaging (MRI), greyscale ultrasonography (GSUS), and power Doppler ultrasonography (PDUS) in patients with early rheumatoid arthritis (RA). Hands of 31 patients with early RA were examined by FOI, MRI, and US. In each modality, synovitis of the wrist, metacarpophalangeal joints (MCP) 2-5, and proximal interphalangeal joints (PIP) 2-5 were scored on a 4-point scale (0-3). Sensitivity and specificity of FOI were analyzed in comparison to MRI and US as reference methods, differentiating between 3 phases of FOI enhancement (P1-3). Intraclass correlation coefficients (ICC) were calculated to evaluate the agreement of FOI with MRI and US. A total of 279 joints (31 wrists, 124 MCP and 124 PIP joints) were evaluated. With MRI as the reference method, overall sensitivity/specificity of FOI was 0.81/0.00, 0.49/0.84, and 0.86/0.38 for wrist, MCP, and PIP joints, respectively. Under application of PDUS as reference, sensitivity was even higher, while specificity turned out to be low, except for MCP joints (0.88/0.15, 0.81/0.76, and 1.00/0.27, respectively). P2 appears to be the most sensitive FOI phase, while P1 showed the highest specificity. The best agreement of FOI was shown for PDUS, especially with regard to MCP and PIP joints (ICC of 0.57 and 0.53, respectively), while correlation with MRI was slightly lower. FOI remains an interesting diagnostic tool for patients with early RA, although this study revealed limitations concerning the detection of synovitis. Further research is needed to evaluate its full diagnostic potential in rheumatic diseases.
40 CFR 35.115 - Evaluation of performance.
Code of Federal Regulations, 2010 CFR
2010-07-01
... requirements for progress reporting under 40 CFR 31.40(b). (b) Elements of the evaluation process. The.... The recipient may request review of the Regional Administrator's decision under the dispute processes... Evaluation of performance. (a) Joint evaluation process. The applicant and the Regional Administrator will...
Evaluation of longitudinal joint tie bar system.
DOT National Transportation Integrated Search
2011-09-01
"An adequate longitudinal joint tie bar system is essential in the overall performance of concrete pavement. Excessive : longitudinal joint openings are believed to be caused by either inadequate tie bar size or spacing or improper tie bar : installa...
Evaluation of Longitudinal Joints of HMA Pavements in Tennessee
DOT National Transportation Integrated Search
2010-05-01
Longitudinal joints between lanes of hot-mix asphalt (HMA) pavements are commonly susceptible to moisture damage and other failures. In 2006, the Tennessee Department of Transportation (TDOT) identified longitudinal joint failure as one of the major ...
Longitudinal joint treatment : construction report.
DOT National Transportation Integrated Search
2000-05-01
Maine highways have been showing signs of longitudinal joint failure for a number of : years. In an effort to reduce the amount of joint failures the Maine Department of : Transportation (MDOT) is currently evaluating two projects. One project is mon...
Test and analysis of Celion 3000/PMR-15, graphite/polyimide bonded composite joints: Data report
NASA Technical Reports Server (NTRS)
Cushman, J. B.; Mccleskey, S. F.; Ward, S. H.
1982-01-01
Standard single lap, double lap and symmetric step lap bonded joints of Celion 3000/PMR-15 graphite/polyimide composite were evaluated. Composite to composite and composite to titanium joints were tested at 116 K (-250 F), 294 K (70 F) and 561 K (550 F). Joint parameters evaluated are lap length, adherend thickness, adherend axial stiffness, lamina stacking sequence and adherend tapering. Advanced joint concepts were examined to establish the change in performance of preformed adherends, scalloped adherends and hybrid systems. The material properties of the high temperature adhesive, designated A7F, used for bonding were established. The bonded joint tests resulted in interlaminar shear or peel failures of the composite and there were very few adhesive failures. Average test results agree with expected performance trends for the various test parameters. Results of finite element analyses and of test/analysis correlations are also presented.
The Superfund Innovative Technology Evaluation Program SUMMARY AND CLOSURE REPORT
The Superfund Innovative Technology Evaluation (SITE) Program promoted the development, commercialization, and implementation of innovative hazardous waste treatment technologies for 20 years. SITE offered a mechanism for conducting joint technology demonstration and evaluation ...
NASA Astrophysics Data System (ADS)
Omar, R.; Rani, M. N. Abdul; Yunus, M. A.; Mirza, W. I. I. Wan Iskandar; Zin, M. S. Mohd
2018-04-01
A simple structure with bolted joints consists of the structural components, bolts and nuts. There are several methods to model the structures with bolted joints, however there is no reliable, efficient and economic modelling methods that can accurately predict its dynamics behaviour. Explained in this paper is an investigation that was conducted to obtain an appropriate modelling method for bolted joints. This was carried out by evaluating four different finite element (FE) models of the assembled plates and bolts namely the solid plates-bolts model, plates without bolt model, hybrid plates-bolts model and simplified plates-bolts model. FE modal analysis was conducted for all four initial FE models of the bolted joints. Results of the FE modal analysis were compared with the experimental modal analysis (EMA) results. EMA was performed to extract the natural frequencies and mode shapes of the test physical structure with bolted joints. Evaluation was made by comparing the number of nodes, number of elements, elapsed computer processing unit (CPU) time, and the total percentage of errors of each initial FE model when compared with EMA result. The evaluation showed that the simplified plates-bolts model could most accurately predict the dynamic behaviour of the structure with bolted joints. This study proved that the reliable, efficient and economic modelling of bolted joints, mainly the representation of the bolting, has played a crucial element in ensuring the accuracy of the dynamic behaviour prediction.
Schumacher, J; Steiger, R; Schumacher, J; de Graves, F; Schramme, M; Smith, R; Coker, M
2000-01-01
To determine if pain of the dorsal margin of the sole in horses can be attenuated by anesthesia of either the distal interphalangeal (DIP) joint or the palmar digital (PD) nerves. A unilateral forelimb lameness was induced by creating solar pain. Response to administration of local anesthetic or saline solution into the DIP joint and to administration of local anesthetic around the PD nerves was evaluated. Six horses. Lameness was induced by creating pressure on the dorsal margin of the sole by screwing set-screws into a nut welded to the inside of each branch of a shoe. Gaits were evaluated before and after application of set-screws and after a local anesthetic or saline solution was administered into the DIP joint and, in a second trial, after a local anesthetic was injected around the PD nerves. Gaits recorded on videotape were evaluated, and lameness scores were assigned to each gait. Lameness scores were high after application of set-screws and remained high after saline solution was administered into the DIP joint. Scores decreased significantly (P < or = .05) after a local anesthetic was administered into the DIP joint or around the PD nerves. Analgesia of the DIP joint or the PD nerves desensitizes at least a portion of the sole. Pain arising from the sole should not be excluded as a cause of lameness when lameness is attenuated by analgesia of the DIP joint or PD nerves.
Giancane, Gabriella; Pederzoli, Silvia; Norambuena, Ximena; Ioseliani, Maka; Sato, Juliana; Gallo, Maria Chiara; Negro, Giorgia; Pistorio, Angela; Ruperto, Nicolino; Martini, Alberto; Ravelli, Angelo
2014-01-01
To evaluate the presence and progression of radiographic joint damage, as assessed with the adapted Sharp/van der Heijde score (SHS), in individual joints in the hand and wrist in patients with juvenile idiopathic arthritis (JIA) and to compare progression of damage among different JIA categories. A total of 372 radiographs of both wrists and hands obtained at first observation and at last followup visit (after 1-10 years) in 186 children with polyarticular-course JIA were evaluated. All radiographs were scored using the adapted SHS by 2 independent readers. Radiographic assessment included evaluation of joint space narrowing (JSN) and erosions on baseline and last followup radiographs and of progression of radiographic changes from baseline to last followup radiographs. Both JSN and erosions occurred in all adapted SHS areas. Overall, radiographic damage and progression were more common in the wrist and less common in metacarpophalangeal (MCP) joints. The hamate and capitate areas appeared particularly vulnerable to cartilage loss. Erosions were identified most frequently in the hamate and capitate bones as well as in the second and third metacarpal bases. Patients with extended oligoarthritis were distinctly less susceptible to JSN in hand joints, whereas patients with polyarthritis showed a greater tendency to developing erosions in hand joints. Radiographic joint damage and progression in our patients with JIA were seen most commonly in the wrist and less commonly in MCP joints. The frequency and localization of structural abnormalities differed markedly across disease categories. Copyright © 2014 by the American College of Rheumatology.
40 CFR 35.515 - Evaluation of performance.
Code of Federal Regulations, 2010 CFR
2010-07-01
....515 Evaluation of performance. (a) Joint evaluation process. The applicant and the Regional... work plan (see section 35.507(b)(2)(iv)). A description of the evaluation process and reporting... annually and must satisfy the requirements for progress reporting under 40 CFR 31.40(b). (b) Elements of...
Fatigue Crack Growth Behavior of Gas Metal Arc Welded AISI 409 Grade Ferritic Stainless Steel Joints
NASA Astrophysics Data System (ADS)
Lakshminarayanan, A. K.; Shanmugam, K.; Balasubramanian, V.
2009-10-01
The effect of filler metals such as austenitic stainless steel, ferritic stainless steel, and duplex stainless steel on fatigue crack growth behavior of the gas metal arc welded ferritic stainless steel joints was investigated. Rolled plates of 4 mm thickness were used as the base material for preparing single ‘V’ butt welded joints. Center cracked tensile specimens were prepared to evaluate fatigue crack growth behavior. Servo hydraulic controlled fatigue testing machine with a capacity of 100 kN was used to evaluate the fatigue crack growth behavior of the welded joints. From this investigation, it was found that the joints fabricated by duplex stainless steel filler metal showed superior fatigue crack growth resistance compared to the joints fabricated by austenitic and ferritic stainless steel filler metals. Higher yield strength and relatively higher toughness may be the reasons for superior fatigue performance of the joints fabricated by duplex stainless steel filler metal.
NASA Astrophysics Data System (ADS)
Prapavat, Viravuth; Schuetz, Rijk; Runge, Wolfram; Beuthan, Juergen; Mueller, Gerhard J.
1995-12-01
This paper presents in-vitro-studies using the scattered intensity distribution obtained by cw- transillumination to examine the condition of rheumatic disorders of interphalangeal joints. Inflammation of joints, due to rheumatic diseases, leads to changes in the synovial membrane, synovia composition and content, and anatomic geometrical variations. Measurements have shown that these rheumatic induced inflammation processes result in a variation in optical properties of joint systems. With a scanning system the interphalangeal joint is transilluminated with diode lasers (670 nm, 905 nm) perpendicular to the joint cavity. The detection of the entire distribution of the transmitted radiation intensity was performed with a CCD camera. As a function of the structure and optical properties of the transilluminated volume we achieved distributions of scattered radiation which show characteristic variations in intensity and shape. Using signal and image processing procedures we evaluated the measured scattered distributions regarding their information weight, shape and scale features. Mathematical methods were used to find classification criteria to determine variations of the joint condition.
Longitudinal joint treatment : first interim report.
DOT National Transportation Integrated Search
2000-11-01
Maine highways have been showing signs of longitudinal joint failure for a number of : years. In an effort to reduce the amount of joint failures the Maine Department of : Transportation (MDOT) is currently evaluating two projects. One project is mon...
Longitudinal joint treatment : second interim report.
DOT National Transportation Integrated Search
2001-09-01
Maine highways have been showing signs of longitudinal joint failure for a : number of years. In an effort to reduce the amount of joint failures the Maine : Department of Transportation (MDOT) is currently evaluating two projects. One : project is m...
Huo, Yinghe; Vincken, Koen L; van der Heijde, Desiree; de Hair, Maria J H; Lafeber, Floris P; Viergever, Max A
2017-11-01
Objective: Wrist joint space narrowing is a main radiographic outcome of rheumatoid arthritis (RA). Yet, automatic radiographic wrist joint space width (JSW) quantification for RA patients has not been widely investigated. The aim of this paper is to present an automatic method to quantify the JSW of three wrist joints that are least affected by bone overlapping and are frequently involved in RA. These joints are located around the scaphoid bone, viz. the multangular-navicular, capitate-navicular-lunate, and radiocarpal joints. Methods: The joint space around the scaphoid bone is detected by using consecutive searches of separate path segments, where each segment location aids in constraining the subsequent one. For joint margin delineation, first the boundary not affected by X-ray projection is extracted, followed by a backtrace process to obtain the actual joint margin. The accuracy of the quantified JSW is evaluated by comparison with the manually obtained ground truth. Results: Two of the 50 radiographs used for evaluation of the method did not yield a correct path through all three wrist joints. The delineated joint margins of the remaining 48 radiographs were used for JSW quantification. It was found that 90% of the joints had a JSW deviating less than 20% from the mean JSW of manual indications, with the mean JSW error less than 10%. Conclusion: The proposed method is able to automatically quantify the JSW of radiographic wrist joints reliably. The proposed method may aid clinical researchers to study the progression of wrist joint damage in RA studies. Objective: Wrist joint space narrowing is a main radiographic outcome of rheumatoid arthritis (RA). Yet, automatic radiographic wrist joint space width (JSW) quantification for RA patients has not been widely investigated. The aim of this paper is to present an automatic method to quantify the JSW of three wrist joints that are least affected by bone overlapping and are frequently involved in RA. These joints are located around the scaphoid bone, viz. the multangular-navicular, capitate-navicular-lunate, and radiocarpal joints. Methods: The joint space around the scaphoid bone is detected by using consecutive searches of separate path segments, where each segment location aids in constraining the subsequent one. For joint margin delineation, first the boundary not affected by X-ray projection is extracted, followed by a backtrace process to obtain the actual joint margin. The accuracy of the quantified JSW is evaluated by comparison with the manually obtained ground truth. Results: Two of the 50 radiographs used for evaluation of the method did not yield a correct path through all three wrist joints. The delineated joint margins of the remaining 48 radiographs were used for JSW quantification. It was found that 90% of the joints had a JSW deviating less than 20% from the mean JSW of manual indications, with the mean JSW error less than 10%. Conclusion: The proposed method is able to automatically quantify the JSW of radiographic wrist joints reliably. The proposed method may aid clinical researchers to study the progression of wrist joint damage in RA studies.
Influence of control parameters on the joint tracking performance of a coaxial weld vision system
NASA Technical Reports Server (NTRS)
Gangl, K. J.; Weeks, J. L.
1985-01-01
The first phase of a series of evaluations of a vision-based welding control sensor for the Space Shuttle Main Engine Robotic Welding System is described. The robotic welding system is presently under development at the Marshall Space Flight Center. This evaluation determines the standard control response parameters necessary for proper trajectory of the welding torch along the joint.
ERIC Educational Resources Information Center
Joint Council on Economic Education, New York, NY.
The Materials Evaluation Committee of the Joint Council reviewed both print and non-print supplementary student materials for economics in order to make this selected list of those materials thought to be suitable according to: 1) whether the materials are genuinely concerned with economic matters; 2) whether they are analytical in nature; and, 3)…
SUPERFUND INNOVATIVE TECHNOLOGY EVALUATION PROGRAM ANNUAL REPORT TO CONGRESS FY2000
The Superfund Innovative Technology Evaluation Program promotes the development, commercialization, and implementation of innovative hazardous waste treatment technologies. SITE offers a mechanism for conducting joint demonstration and evaluation projects at hazardous waste site...
Dalto, Vitor Faeda; Assad, Rodrigo Luppino; Crema, Michel Daoud; Louzada-Junior, Paulo; Nogueira-Barbosa, Marcello Henrique
2017-09-01
To compare short tau inversion-recovery (STIR) with another fat saturation method in the assessment of sacroiliac joint inflammation. This prospective cross-sectional study comprised 76 spondyloarthritis (SpA) patients who underwent magnetic resonance imaging of the sacroiliac joints in a 1.5-T scanner, using STIR, spectral attenuated inversion recovery (SPAIR) T2w and spectral presaturation with inversion recovery (SPIR) T1w post-contrast sequences. Two independent readers (R1 and R2) assessed the images using the Spondyloarthritis Research Consortium of Canada (SPARCC) score. We assessed agreement of the SPARCC scores for SPAIR T2w and STIR with that for T1 SPIR post-contrast (reference standard) using the St. Laurent coefficient. We evaluated each sequence using the concordance correlation coefficient (CCC). We observed a strong agreement between STIR and SPAIR T2w sequences. Lin's CCC was 0.94 for R1 and 0.84 for R2 for STIR and 0.94 for R1 and 0.84 for R2 for SPAIR. The interobserver evaluation revealed a good CCC of 0.79 for SPAIR and 0.78 for STIR. STIR technique and SPAIR T2w sequence showed high agreement in the evaluation of sacroiliac joint subchondral bone marrow oedema in patients with SpA. SPAIR T2w may be an alternative to the STIR sequence for this purpose. • There are no studies evaluating which fat saturation technique should be used. • SPAIR T2w may be an alternative to STIR for sacroiliac joint evaluation. • The study will lead to changes in guidelines for spondyloarthritis.
Evaluation of Margins of Safety in Brazed Joints
NASA Technical Reports Server (NTRS)
Flom, Yury; Wang, Len; Powell, Mollie M.; Soffa, Matthew A.; Rommel, Monica L.
2009-01-01
One of the essential steps in assuring reliable performance of high cost critical brazed structures is the assessment of the Margin of Safety (MS) of the brazed joints. In many cases the experimental determination of the failure loads by destructive testing of the brazed assembly is not practical and cost prohibitive. In such cases the evaluation of the MS is performed analytically by comparing the maximum design loads with the allowable ones and incorporating various safety or knock down factors imposed by the customer. Unfortunately, an industry standard methodology for the design and analysis of brazed joints has not been developed. This paper provides an example of an approach that was used to analyze an AlBeMet 162 (38%Be-62%Al) structure brazed with the AWS BAlSi-4 (Al-12%Si) filler metal. A practical and conservative interaction equation combining shear and tensile allowables was developed and validated to evaluate an acceptable (safe) combination of tensile and shear stresses acting in the brazed joint. These allowables are obtained from testing of standard tensile and lap shear brazed specimens. The proposed equation enables the assessment of the load carrying capability of complex brazed joints subjected to multi-axial loading.
The serpentine end-matched joint: evaluating strength and stability
Charles J. Gatchell; Curtis C. Peters
1981-01-01
The Serpentine end-matched (Sem) joint is a precisely machined butt joint with a sine wave shape. The joint is not readily visible to the eye and performs well in panels made of sugar maple, red oak, black walnut, and black cherry. The Sem joint is unaffected by changes in equilibrium moisture content from 6 to 12 to 18 to 6 percent. Panels containing Sem joints have...
Evaluation of the Hip: History and Physical Examination
2007-01-01
Examination of a painful hip is fairly concise and reliable at detecting the presence of a hip joint problem. Hip joint disorders often go undetected, leading to the development of secondary disorders. Using a thoughtful approach and methodical examination techniques, most hip joint problems can be detected and a proper treatment strategy can then be implemented based on an accurate diagnosis. The purpose of this clinical commentary is to present a systematic examination process that outlines important components in each of the evaluation areas of history and physical examination (including inspection, measurements, symptom localization, muscle strength, and special tests). PMID:21509142
DOT National Transportation Integrated Search
2005-10-01
The Specific Pavement Studies 6 (SPS-6) experiment, "Rehabilitation of Jointed Portland Cement Concrete Pavements," was designed as a controlled field experiment that focuses on the study of specific rehabilitation design features of jointed plain co...
Longitudinal joint treatment, interim report - third year, March 2004.
DOT National Transportation Integrated Search
2004-03-01
Maine highways have been showing signs of longitudinal joint failure for a number of years. In an effort : to reduce the amount of joint failures the Maine Department of Transportation (MDOT) is currently : evaluating two projects. One project is mon...
Longitudinal joint treatment, interim report - fourth year, March 2005.
DOT National Transportation Integrated Search
2005-03-01
Maine highways have been showing signs of longitudinal joint failure for a number of years. In an effort : to reduce the amount of joint failures the Maine Department of Transportation (MDOT) is currently : evaluating two projects. One project is mon...
Imaging of the temporomandibular joint: An update
Bag, Asim K; Gaddikeri, Santhosh; Singhal, Aparna; Hardin, Simms; Tran, Benson D; Medina, Josue A; Curé, Joel K
2014-01-01
Imaging of the temporomandibular joint (TMJ) is continuously evolving with advancement of imaging technologies. Many different imaging modalities are currently used to evaluate the TMJ. Magnetic resonance imaging is commonly used for evaluation of the TMJ due to its superior contrast resolution and its ability to acquire dynamic imaging for demonstration of the functionality of the joint. Computed tomography and ultrasound imaging have specific indication in imaging of the TMJ. This article focuses on state of the art imaging of the temporomandibular joint. Relevant normal anatomy and biomechanics of movement of the TMJ are discussed for better understanding of many TMJ pathologies. Imaging of internal derangements is discussed in detail. Different arthropathies and common tumors are also discussed in this article. PMID:25170394
2014-01-01
This report represents the conclusions of a Joint FAO/WHO Expert Committee convened to evaluate the safety of residues of certain veterinary drugs in food and to recommend maximum levels for such residues of food. The first part of the report considers general principles regarding the evaluation of residues of veterinary drugs within the terms of reference of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), including extrapolation of maximum residue limits (MRLs) to minor species, MRLs for veterinary drug residues in honey, MRLs relating to fish and fish species, dietary exposure assessment methodologies, the decision-tree approach to the evaluation of residues of veterinary drugs and guidance for JECFA experts. Summaries follow of the Committee's evaluations of toxicology and residue data on a variety of veterinary drugs: two anthelminthic agents (derquantel, monepantel), three antiparasitic agents (emanectin benzoate, ivermectin, lasalocid sodium), one antibacterial, antifungal and anthelminthic agent (gentian violet), a production aid (recombinant bovine somatotropins) and an adrenoceptor agonist and growth promoter (zilpaterol hydorchloride). Annexed to the report is a summary of the Committee's recommendations on these drugs, including acceptable daily intakes (ADIs)) and proposed MRLs.
Jevtic, V; Watt, I; Rozman, B; Kos-Golja, M; Praprotnik, S; Logar, D; Presetnik, M; Demsar, F; Jarh, O; Campion, G; Musikic, P
1997-01-01
The aim of this prospective 24-month follow-up study was to compare clinical features with radiological and magnetic resonance imaging (MRI) findings in evaluating synovial proliferation in the hand joints of 31 patients with rheumatoid arthritis (RA). A single joint was used for the follow-up of each patient. Thirty-one small hand joints were examined by conventional radiography and MRI before and after 24 months of treatment. MRI assessment of disease progression (volume and/or signal intensity of the synovial proliferation on T1 weighted precontrast, T1 weighted postcontrast and T2 weighted images) was compared with a clinical assessment of the chosen joints, and with a plain x-ray film evaluation (Larsen's score). Of 26 joints which clinically improved (14 markedly and 14 slightly) during the study, on MRI 16 showed improvement, 8 showed no change, and 2 showed deterioration. Four clinically unchanged joints appeared improved on MRI. One joint deteriorated clinically and on MRI. Overall, there was a 58% congruence between clinical and MRI findings. On x-ray 23 joints showed no change; nine of these were also unchanged on MRI, while 13 showed improvement and one deterioration. Only in 2 out of 8 joints showing deterioration on x-ray were the MRI findings in accordance. In the remaining six joints MRI showed improvement. The congruence between x-ray and MRI was therefore 36%. The long-term follow-up of rheumatoid synovial proliferation of the small joints in the hand using contrast enhanced MRI is feasible and may provide additional information regarding disease activity. Important advantages over conventional radiography methods are its ability to demonstrate qualitative differences of synovial proliferation within bone erosions, and demonstrate not only deterioration, but also the improvement of inflammatory disease.
Stone, Millicent A; White, Lawrence M; Gladman, Dafna D; Inman, Robert D; Chaya, Sam; Lax, Matthew; Salonen, David; Weber, Deborah A; Guthrie, Judy A; Pomeroy, Emma; Podbielski, Dominik; Keystone, Edward C
2009-12-01
Rheumatologists base many clinical decisions regarding the management of inflammatory joint diseases on joint counts performed at clinic. We investigated the reliability and accuracy of physically examining the metacarpophalangeal (MCP) joints to detect inflammatory synovitis using magnetic resonance imaging (MRI) as the gold standard. MCP joints 2 to 5 in both hands of 5 patients with rheumatoid arthritis (RA) and 5 with psoriatic arthritis (PsA) were assessed by 5 independent examiners for joint-line swelling (visually and by palpation); joint-line tenderness by palpation (tender joint count, TJC) and stress pain; and by MRI (1.5 Tesla superconducting magnet). Interrater reliability was assessed using kappa statistics, and agreement between examination and corresponding MRI assessment was assessed by Fisher's exact tests (p < 0.05 considered statistically significant). Interrater agreement was highest for visual assessment of swelling (kappa = 0.55-0.63), slight-fair for assessment of swelling by palpation (kappa = 0.19-0.41), and moderate (kappa = 0.41-0.58) for assessment of joint tenderness. In patients with RA, TJC, stress pain, and visual swelling assessment were strongly associated with MRI evaluation of synovitis. Visual swelling assessment demonstrated high specificity (> 0.8) and positive predictive value (= 0.8). For PsA, significant associations exist between TJC and MRI synovitis scores (p < 0.01) and stress pain and MRI edema scores (p < 0.04). Assessment of swelling by palpation was not significantly associated with synovitis or edema as determined by MRI in RA or PsA (p = 0.54-1.0). In inflammatory arthritis, disease activity in MCP joints can be reliably assessed at the bedside by examining for joint-line tenderness (TJC) and visual inspection for swelling. Clinical assessment may have to be complemented by other methods for evaluating disease activity in the joint, such as MRI, particularly in patients with PsA.
An algorithm for the evaluation and treatment of sacroiliac joint dysfunction.
Carlson, Samuel W; Magee, Sean; Carlson, Walter O
2014-11-01
Approximately 90 percent of adults experience an episode of low back pain in their lifetime. Sacroiliac joint (SIJ) dysfunction has been shown to cause approximately 13-30 percent of LBP in the adult population. SIJ fusion is becoming an increasingly popular treatment alternative for SIJ dysfunction. This paper presents a literature-based algorithm to assist the clinician in the evaluation and treatment of patients with suspected SIJ dysfunction.
An Evaluation of Automotive Interior Packages Based on Human Ocular and Joint Motor Properties
NASA Astrophysics Data System (ADS)
Tanaka, Yoshiyuki; Rakumatsu, Takeshi; Horiue, Masayoshi; Miyazaki, Tooru; Nishikawa, Kazuo; Nouzawa, Takahide; Tsuji, Toshio
This paper proposes a new evaluation method of an automotive interior package based on human oculomotor and joint-motor properties. Assuming the long-term driving situation in the express high way, the three evaluation indices were designed on i) the ratio of head motion at gazing the driving items; ii) the load torque for maintaining the standard driving posture; and iii) the human force manipulability at the end-point of human extremities. Experiments were carried out for two different interior packages with four subjects who have the special knowledge on the automobile development. Evaluation results demonstrate that the proposed method can quantitatively analyze the driving interior in good agreement with the generally accepted subjective opinion in the automobile industry.
Sainoh, Takeshi; Takaso, Masashi; Inoue, Gen; Orita, Sumihisa; Eguchi, Yawara; Nakamura, Junichi; Aoki, Yasuchika; Ishikawa, Tetsuhiro; Miyagi, Masayuki; Arai, Gen; Kamoda, Hiroto; Suzuki, Miyako; Kubota, Gou; Sakuma, Yoshihiro; Oikawa, Yasuhiro; Yamazaki, Masashi; Toyone, Tomoaki; Takahashi, Kazuhisa
2012-01-01
Purpose Sacroiliac fixation using iliac screws for highly unstable lumbar spine has been reported with an improved fusion rate and clinical results. On the other hand, there is a potential for clinical problems related to iliac fixation, including late sacroiliac joint arthritis and pain. Materials and Methods Twenty patients were evaluated. Degenerative scoliosis was diagnosed in 7 patients, failed back syndrome in 6 patients, destructive spondyloarthropathy in 4 patients, and Charcot spine in 3 patients. All patients underwent posterolateral fusion surgery incorporating lumbar, S1 and iliac screws. We evaluated the pain scores, bone union, and degeneration of sacroiliac joints by X-ray imaging and computed tomography before and 3 years after surgery. For evaluation of low back and buttock pain from sacroiliac joints 3 years after surgery, lidocaine was administered in order to examine pain relief thereafter. Results Pain scores significantly improved after surgery. All patients showed bone union at final follow-up. Degeneration of sacroiliac joints was not seen in the 20 patients 3 years after surgery. Patients showed slight low back and buttock pain 3 years after surgery. However, not all patients showed relief of the low back and buttock pain after injection of lidocaine into the sacroiliac joint, indicating that their pain did not originate from sacroiliac joints. Conclusion The fusion rate and clinical results were excellent. Also, degeneration and pain from sacroiliac joints were not seen within 3 years after surgery. We recommend sacroiliac fixation using iliac screws for highly unstable lumbar spine. PMID:22318832
Carol A. Clausen; Daniel L. Lindner
2011-01-01
Five-year performance ratings are presented for two types of untreated, uncoated wood joints (L and lap) in aboveground tests under shaded conditions. The effect of shading on moisture entrapment in pine and maple L and lap joints was evaluated in a moderate decay zone (Madison, Wisconsin). Variations were observed between wood species, visual ratings, joint type,...
Vahtrik, Doris; Gapeyeva, Helena; Ereline, Jaan; Pääsuke, Mati
2014-01-01
The aim of the present study was to evaluate an isometric maximal voluntary contraction (MVC) force of the leg extensor muscles and its relationship with knee joint loading during gait prior and after total knee arthroplasty (TKA). Custom-made dynamometer was used to assess an isometric MVC force of the leg extensor muscles and 3-D motion analysis system was used to evaluate the knee joint loading during gait in 13 female patients (aged 49-68 years) with knee osteoarthritis. Patients were evaluated one day before, and three and six months following TKA in the operated and non-operated leg. Six months after TKA, MVC force of the leg extensor muscles for the operated leg did not differ significantly as compared to the preoperative level, whereas it remained significantly lower for the non-operated leg and controls. The knee flexion moment and the knee joint power during mid stance of gait was improved six months after TKA, remaining significantly lowered compared with controls. Negative moderate correlation between leg extensor muscles strength and knee joint loading for the operated leg during mid stance was noted three months after TKA. The correlation analysis indicates that due to weak leg extensor muscles, an excessive load is applied to knee joint during mid stance of gait in patients, whereas in healthy subjects stronger knee-surrounding muscles provide stronger knee joint loading during gait. III (correlational study). Copyright © 2013 Elsevier B.V. All rights reserved.
Lalone, Emily A; Grewal, Ruby; King, Graham W; MacDermid, Joy C
2015-01-01
Some mal-alignment of the wrist occurs in up to 71% of patients following a distal radius fracture. A multiple case study was used to provide proof of principle of an image-based technique to investigate the evolution and impact of post-traumatic joint changes at the distal radioulnar joint. Participants who had a unilateral distal radius fracture who previously participated in a prospective study were recruited from a single tertiary hand center. Long term follow-up measures of pain, disability, range of motion and radiographic alignment were obtained and compared to joint congruency measures. The inter-bone distance, a measure of joint congruency was quantified from reconstructed CT bone models of the distal radius and ulna and the clinical outcome was quantified using the patient rated wrist evaluation. In all four cases, acceptable post-reduction alignment and minimal pain/disability at 1-year suggested good clinical outcomes. However, 10 years following injury, 3 out of 4 patients had radiographic signs of degenerative changes occurring in their injured wrist (distal radioulnar joint/radio-carpal joint). Proximity maps displaying inter-bone distances showed asymmetrical congruency between wrists in these three patients. The 10-year PRWE (patient rated wrist evaluation) varied from 4 to 60, with 3 reporting minimal pain/disability and one experiencing high pain/disability. These illustrative cases demonstrate long-term joint damage post-fracture is common and occurs despite positive short-term clinical outcomes. Imaging and functional outcomes are not necessarily correlated. A novel congruency measure provides an indicator of the overall impact of joint mal-alignment that can be used to determine predictors of post-traumatic arthritis and is viable for clinical or large cohort studies.
Oppong, Raymond; Nicholls, Elaine; Whitehurst, David G. T.; Hill, Susan; Hammond, Alison; Hay, Elaine M.; Dziedzic, Krysia
2015-01-01
Objectives. Evidence regarding the cost-effectiveness of joint protection and hand exercises for the management of hand OA is not well established. The primary aim of this study is to assess the cost-effectiveness (cost-utility) of these management options. In addition, given the absence of consensus regarding the conduct of economic evaluation alongside factorial trials, we compare different analytical methodologies. Methods. A trial-based economic evaluation to assess the cost-utility of joint protection only, hand exercises only and joint protection plus hand exercises compared with leaflet and advice was undertaken over a 12 month period from a UK National Health Service perspective. Patient-level mean costs and mean quality-adjusted life years (QALYs) were calculated for each trial arm. Incremental cost-effectiveness ratios (ICERs) were estimated and cost-effectiveness acceptability curves were constructed. The base case analysis used a within-the-table analysis methodology. Two further methods were explored: the at-the-margins approach and a regression-based approach with or without an interaction term. Results. Mean costs (QALYs) were £58.46 (s.d. 0.662) for leaflet and advice, £92.12 (s.d. 0.659) for joint protection, £64.51 (s.d. 0.681) for hand exercises and £112.38 (s.d. 0.658) for joint protection plus hand exercises. In the base case, hand exercises were the cost-effective option, with an ICER of £318 per QALY gained. Hand exercises remained the most cost-effective management strategy when adopting alternative methodological approaches. Conclusion. This is the first trial evaluating the cost-effectiveness of occupational therapy-supported approaches to self-management for hand OA. Our findings showed that hand exercises were the most cost-effective option. PMID:25339642
DOT National Transportation Integrated Search
2017-03-01
Joints are often considered as the weak link in a structure and often deterioration of the structure initiates from the : joints. Joints transfer the stresses from super-structure to sub-structure and in this process are subjected to large : transfer...
Structural attachments for large space structures
NASA Technical Reports Server (NTRS)
Pruett, E. C.; Loughead, T. E.; Robertson, K. B., III
1980-01-01
The feasibility of fabricating beams in space and using them as components of a large, crew assembled structure, was investigated. Two projects were undertaken: (1) design and development of a ground version of an automated beam builder capable of producing triangular cross section aluminum beams; and (2) design and fabrication of lap joints to connect the beams orthogonally and centroidal end caps to connect beams end to end at any desired angle. The first project produced a beam building machine which fabricates aluminum beams suitable for neutral buoyancy evaluation. The second project produced concepts for the lap joint and end cap. However, neither of these joint concepts was suitable for use by a pressure suited crew member in a zero gravity environment. It is concluded that before the beams can be evaluated the joint designs need to be completed and sufficient joints produced to allow assembly of a complex structure.
Ganglion cyst arising from the composite occipito-atlanto-axial joint cavity in a cat.
Aikawa, T; Sadahiro, S; Nishimura, M; Miyazaki, Y; Shibata, M
2014-01-01
A four-year-old, female spayed Domestic Longhaired cat was referred for evaluation with a two month history of initial inability to jump progressing to ambulatory tetraparesis. Magnetic resonance imaging studies demonstrated a cystic lesion arising from the composite occipito-atlanto-axial joint cavity and extending to the region of the occipital bone and the axis. The lesion surrounded the spinal canal, causing moderate dorsal spinal cord compression at the atlanto-occipital joint. A dynamic myelographic study demonstrated attenuation of the dorsal contrast column at the atlanto-occipital joint when the cervical spine was positioned in extension. Partial excision of the cyst capsule by a ventral approach resulted in long-term (64 months) resolution of clinical signs. Histological evaluation was consistent with a ganglion cyst. An intra-spinal ganglion cyst arising from the composite occipito-atlanto-axial joint cavity may be considered as an uncommon differential diagnosis for cats with cervical myelopathy.
Technical Evaluation Motor no. 5 (TEM-5)
NASA Technical Reports Server (NTRS)
Cook, M.
1990-01-01
Technical Evaluation Motor No. 5 (TEM-5) was static test fired at the Thiokol Corporation Static Test Bay T-97. TEM-5 was a full scale, full duration static test fire of a high performance motor (HPM) configuration solid rocket motor (SRM). The primary purpose of TEM static tests is to recover SRM case and nozzle hardware for use in the redesigned solid rocket motor (RSRM) flight program. Inspection and instrumentation data indicate that the TEM-5 static test firing was successful. The ambient temperature during the test was 41 F and the propellant mean bulk temperature (PMBT) was 72 F. Ballistics performance values were within the specified requirements. The overall performance of the TEM-5 components and test equipment was nominal. Dissembly inspection revealed that joint putty was in contact with the inner groove of the inner primary seal of the ignitor adapter-to-forward dome (inner) joint gasket; this condition had not occurred on any previous static test motor or flight RSRM. While no qualification issues were addressed on TEM-5, two significant component changes were evaluated. Those changes were a new vented assembly process for the case-to-nozzle joint and the installation of two redesigned field joint protection systems. Performance of the vented case-to-nozzle joint assembly was successful, and the assembly/performance differences between the two field joint protection system (FJPS) configurations were compared.
77 FR 506 - Agency Information Collection Request. 30-Day Public Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-05
.... Proposed Project: Teen Pregnancy Prevention Replication Evaluation Study: Baseline Data Collection--OMB No... for Children and Families (ACF) on adolescent pregnancy prevention evaluation activities. OAH will jointly oversee with ASPE the Teen Pregnancy Prevention Replication Evaluation Study (TPP Replication...
Hinz, Antje; Fischer, Andrew T
2011-10-01
To compare the accuracy of ultrasonographic and radiographic examination for evaluation of articular lesions in horses. Cross-sectional study. Horses (n = 137) with articular lesions. Radiographic and ultrasonographic examinations of the affected joint(s) were performed before diagnostic or therapeutic arthroscopic surgery. Findings were recorded and compared to lesions identified during arthroscopy. In 254 joints, 432 lesions were identified by arthroscopy. The overall accuracy was 82.9% for ultrasonography and 62.2% for radiography (P < .0001) with a sensitivity of 91.4% for ultrasonography and 66.7% for radiography (P < .0001). The difference in specificity was not statistically significant (P = .2628). The negative predictive value for ultrasonography was 31.5% and 13.2% for radiography (P = .0022), the difference for the positive predictive value was not statistically significant (P = .3898). The accuracy for ultrasonography and radiography for left versus right joints was equal and corresponded with the overall results. Ultrasonographic evaluation of articular lesions was more accurate than radiographic evaluation. © Copyright 2011 by The American College of Veterinary Surgeons.
Sheveleva, N; Minbayeva, L; Belyayeva, Y
2017-03-01
Reducing of articular cartilage functional volume in knee joint osteoarthritis occurs unevenly and accompanied with pathological changes of lower limb axis as a result of connective tissue and muscle structures dysfunction. Evaluation of X-ray knee joint space asymmetry seems to be informative to analyze the dynamics of lower extremities biomechanical imbalances characteristic for knee joint osteoarthritis. However, standardized method of X-ray joint space determining does not include its symmetry calculation. The purpose of the study was optimization of knee joint radiological examination by developing of X-ray knee joint space asymmetry index calculation method. The proposed method was used for comparative analysis of extracorporeal shock-wave therapy efficacy in 30 patients with knee joint osteoarthritis of 2-3 degrees (Kellgren-Lawrence, 1957). As a result of the conducted treatment statistically significant decrease of the X-ray knee joint space asymmetry index was observed (Me(Q1;Q3): Z=5.20, p<0.001) and amounted as 0.22 (0.18;0.24) before treatment and 0.12 (0.10;0.14) after. Also, statistically significant (Z=5.10; p=0.00001) changes of load asymmetry on front and rear foot sections were observed by the results of podometric survey in comparative assessment before (Me(Q1;Q3)=24(12;30)) and after (Me(Q1;Q3)=6(4;30)) course therapy. 30% (n=9) of the patients evaluated the outcome of the treatment as "excellent" (1 point), 63% (n=19) - as "good" (2 points) and only 7% (n=2) - as "acceptable" (3 points) according to the Roles and Maudsley score. The listed above data was regarded as an X-ray positive dynamics comparable with clinical improvement. Thus, the X-ray knee joint space asymmetry index, calculated according to the proposed method, allows to evaluate dynamics of articular surfaces congruency changes and provide differentiated approach to the treatment of knee joint osteoarthritis.
Development and evaluation of a musculoskeletal model of the elbow joint complex
NASA Technical Reports Server (NTRS)
Gonzalez, Roger V.; Hutchins, E. L.; Barr, Ronald E.; Abraham, Lawrence D.
1993-01-01
This paper describes the development and evaluation of a musculoskeletal model that represents human elbow flexion-extension and forearm pronation-supination. The length, velocity, and moment arm for each of the eight musculotendon actuators were based on skeletal anatomy and position. Musculotendon parameters were determined for each actuator and verified by comparing analytical torque-angle curves with experimental joint torque data. The parameters and skeletal geometry were also utilized in the musculoskeletal model for the analysis of ballistic elbow joint complex movements. The key objective was to develop a computational model, guided by parameterized optimal control, to investigate the relationship among patterns of muscle excitation, individual muscle forces, and movement kinematics. The model was verified using experimental kinematic, torque, and electromyographic data from volunteer subjects performing ballistic elbow joint complex movements.
Aksahin, Ertugrul; Aktekin, Cem Nuri; Kocadal, Onur; Duran, Semra; Gunay, Cüneyd; Kaya, Defne; Hapa, Onur; Pepe, Murad
2017-10-01
The aims of this study were to evaluate sagittal plane alignment in patients with chondromalacia patella via magnetic resonance imaging (MRI), analyse the relationships between the location of the patellar cartilaginous lesions and sagittal alignment and finally investigate the relationships between the sagittal plane malalignment and patellofemoral loadings using by finite element analysis. Fifty-one patients who were diagnosed with isolated modified Outerbridge grade 3-4 patellar chondromalacia based on MRI evaluation and 51 control subjects were evaluated. Chondromalacia patella patients were divided into three subgroups according to the chondral lesion location as superior, middle and inferior. The patella-patellar tendon angle (P-PT) was used for evaluation of sagittal alignment of patellofemoral joint. Each subgroup was compared with control group by using P-PT angle. To investigate the biomechanical effects of sagittal plane malpositioning on patellofemoral joint, bone models were created at 30°, 60° and 90° knee flexion by using mean P-PT angles, which obtained from patients with chondromalacia patellae and control subjects. The total loading and contact area values of the patellofemoral joints were investigated by finite element analysis. The mean age of all participants was 52.9 ± 8.2 years. The mean P-PT angle was significantly lower in chondromalacia group (142.1° ± 3.6°) compared to control group (144.5° ± 5.3°) (p = 0.008). Chondral lesions were located in superior, middle and inferior zones in 16, 20 and 15 patients, respectively. The mean P-PT angles in patients with superior (141.8 ± 2.7) and inferior subgroups (139.2 ± 2.3) were significantly lower than the values in the control group (p < 0.05). The contact area values were detected higher in models with chondromalacia than in the control models at the same flexion degrees. There were increased loadings at 30° and 90° flexions in the sagittal patellar tilt models. This study revealed that sagittal plain malpositioning of the patellofemoral joint might be related to chondromalacia, especially in the presence of lesions in the upper and lower part of the patella. This condition leads to supraphysiological loadings on the patellofemoral joint. Sagittal patellar tilt should be considered in the evaluation and management of patellar cartilage defects. Taking sagittal plane malalignment into consideration in patellofemoral joint evaluation will enable us to design new physical and surgical modalities. IV.
NASA Technical Reports Server (NTRS)
Thome, Kurt; Goldberg, Mitch; Mita, Dath; Stensaas, Gregory L.
2013-01-01
The National Aeronautics and Space Administration (NASA), National Oceanic and Atmospheric Administration (NOAA), the United States Department of Agriculture (USDA), and the United States Geological Survey (USGS), and their associates and partners, are directly responsible for establishing and leading a unique interagency team of scientists and engineers who work together to evaluate and enhance the quality remote sensing data for commercial and government use. This team is called "the Joint Agency Commercial Imagery Evaluation (JACIE) team". The team works together to define, prioritize, assign, and assess civil and commercial image quality and jointly sponsors an annual JACIE Civil Commercial Imagery Evaluation workshop with participation support from the remote sensing calibration and validation science community.
Cheng, Yin-Hui; Yu, Annie P; Huang, Molly Chien-Jung; Dai, Chia-Jung
2017-01-01
Most research on preference reversal (PR) focuses on the evaluability hypothesis with one or two alternatives. However, people normally encounter more than two options in daily life. In this research, a third option was added to the PR effect choice sets in the traditional joint-separate evaluations mode to create a context effect. Three studies were conducted. Studies 1 and 2 showed that adding a third option to the choice sets changed the PR effect; either the attributes were both important or one was important and the other was not. Study 3 showed that the PR effect reappeared when a third option was added to the choice sets that had no PR effect with just two attributes that were difficult to evaluate independently in traditional evaluations modes. The three studies confirmed that preferences changed in multi-alternative evaluation modes, contradicting Hsee's (1996) work and showing that the context effect is stronger than that of the attribute's importance in the PR effect.
Independent Consulting and the American Evaluation Association: Twenty Years Later
ERIC Educational Resources Information Center
Bonnet, Deborah G.
2006-01-01
This article reviews the evolution of American Evaluation Association's (AEA) Independent Consulting Topical Interest Group (IC TIG). The TIG goes back a joint meeting held in San Francisco in 1984 of the Evaluation Network (ENet) and the Evaluation Research Society (ERS), two years before the organizations merged to become the AEA. On the fringes…
Scillia, Anthony; Issa, Kimona; McInerney, Vincent K; Milman, Edward; Baltazar, Romulo; Dasti, Umer; Festa, Anthony
2015-08-01
The purpose of this study was to evaluate the accuracy of in vivo acromioclavicular (AC) joint injections without fluoroscopic guidance and assess whether patient demographics affected the accuracy of injections. A consecutive cohort of patients who presented with painful acromioclavicular joints was prospectively evaluated. All patients had clinical and radiographic evidence of AC arthritis, had failed conservative measures, and thus had received intraarticular corticosteroid injections. All injections were performed by experienced fellowship-trained musculoskeletal radiologists and by blinded digital palpation technique. Accuracy of injections was assessed with biplanar fluoroscopic views. Forty-one AC injections in 22 males and 16 females with a mean age of 51 years (range 18 to 78) were identified. Twenty-three injections were in the right shoulder and 18 in the left. Only 15 injections were confirmed to be in the intraarticular AC joint, yielding an accuracy of 36.5%. There were no significant differences in the mean age (54 vs. 52 years; p = 0.58), male-to-female ratio (p = 0.73), and side of the injection between the accurate and inaccurate injections, respectively. Based on the findings of the present study, the authors encourage the use of image guidance for corticosteroid treatment of the AC joint. Level IV Therapeutic Case Series.
Nishitani, Kohei; Ito, Hiromu; Shimozono, Yoshiharu; Furu, Moritoshi; Azukizawa, Masayuki; Hashimoto, Motomu; Tanaka, Masao; Mimori, Tsuneyo; Matsuda, Shuichi
2017-01-01
The purpose of this study is to investigate the compensatory correlation between knee and hindfoot in patients with rheumatoid arthritis (RA). This cross-sectional study included 218 patients (407 lower extremities). Radiographs of the hindfoot and full-length posteroanterior hip-to-calcaneus standing radiographs were evaluated. The destruction of the hindfoot was evaluated using the Larsen grading system. The coronal angular deformity of the knee and hindfoot was evaluated by the femorotibial angle (FTA) and the angle between the tibial shaft and the entire hindfoot (tibiohindfoot angle, THFA). The correlation between FTA and THFA was determined by Pearson's coefficient. For all patients, FTA correlated to THFA ( R = 0.28, p < 0.001). The correlation was observed as long as the talocrural joint was preserved (Larsen grade ≤ 2), even if the subtalar joint had been destroyed (Larsen grade ≥ 3). However, the correlation was not observed when the talocrural joint was destroyed (Larsen grade ≥ 3, R = -0.02, p = 0.94). The pain in the hindfoot did not correlate with FTA or THFA. In conclusion, a compensatory deformity of the hindfoot against the deformity of the knee was observed in RA, and the correlation was lost when talocrural joint was destroyed.
Space suit glove design with advanced metacarpal phalangeal joints and robotic hand evaluation.
Southern, Theodore; Roberts, Dustyn P; Moiseev, Nikolay; Ross, Amy; Kim, Joo H
2013-06-01
One area of space suits that is ripe for innovation is the glove. Existing models allow for some fine motor control, but the power grip--the act of grasping a bar--is cumbersome due to high torque requirements at the knuckle or metacarpal phalangeal joint (MCP). This area in particular is also a major source of complaints of pain and injury as reported by astronauts. This paper explores a novel fabrication and patterning technique that allows for more freedom of movement and less pain at this crucial joint in the manned space suit glove. The improvements are evaluated through unmanned testing, manned testing while depressurized in a vacuum glove box, and pressurized testing with a robotic hand. MCP joint flex score improved from 6 to 6.75 (out of 10) in the final glove relative to the baseline glove, and torque required for flexion decreased an average of 17% across all fingers. Qualitative assessments during unpressurized and depressurized manned testing also indicated the final glove was more comfortable than the baseline glove. The quantitative results from both human subject questionnaires and robotic torque evaluation suggest that the final iteration of the glove design enables flexion at the MCP joint with less torque and more comfort than the baseline glove.
Viklund, Å; Furre, S; Eriksson, S; Vangen, O; Philipsson, J
2015-08-01
Breeding programmes for warmblood sport horses are similar in the Nordic countries Sweden, Denmark, Finland and Norway, and stallions of same origin are used. The aim was to investigate whether a joint Nordic genetic evaluation based on lifetime competition performance is feasible and beneficial for breeding competitive sport horses in the Nordic countries. Results for almost 45,000 horses in show jumping and 30,000 horses in dressage were available. The larger populations in Sweden and Denmark contributed with 85% of the results. Heritabilities and genetic correlations between performances in the different countries were estimated, and comparisons of accuracies of estimated breeding values (EBVs) and number of stallions with EBVs based on national or joint data were studied. The heritabilities ranged between 0.25 and 0.42 for show jumping and between 0.14 and 0.55 for dressage. The genetic correlations between competition performances in the Nordic countries were estimated to 0.63-1.00. EBVs based on joint data increased accuracies for EBVs for stallions by 38-81% and increased the number of available stallions with EBVs by 40-288%, compared to EBVs based on national data only. A joint Nordic genetic evaluation for sport horses is recommended. © 2015 Blackwell Verlag GmbH.
Implementation of the IHR Joint External Evaluation: Taiwan's Experiences.
Lo, Yi-Chun
In February 2016, the World Health Organization developed the Joint External Evaluation (JEE) tool to independently assess country capacity to prevent, detect, and respond to public health threats as part of the International Health Regulations (IHR) (2005) monitoring and evaluation framework. In light of this, the Taiwan government actively engaged at least 19 government agencies or institutions and voluntarily implemented the JEE. An External Assessment Team consisting of 6 US subject matter experts conducted the external evaluation, including site visits, from June 21 to July 1, 2016. The results, published on October 18, 2016, are useful and will be translated into actions and change in the system. Based on Taiwan's experiences, early stakeholder engagement and an experts' pre-JEE pilot visit would contribute to a successful JEE process.
Fixed-flexion view X-ray of the knee superior in detection and follow-up of knee osteoarthritis
Kan, Hiroyuki; Arai, Yuji; Kobayashi, Masashi; Nakagawa, Shuji; Inoue, Hiroaki; Hino, Manabu; Komaki, Shintaro; Ikoma, Kazuya; Ueshima, Keiichiro; Fujiwara, Hiroyoshi; Yokota, Isao; Kubo, Toshikazu
2017-01-01
Abstract A fixed flexion view (FFV) is useful for evaluating joint space when assessing the severity of osteoarthritis (OA) of the knee. We analyzed changes in joint space revealed by standing extended view (SEV) and FFV over a mean 4 years, to compare both views on their capacity to measure joint space width accurately at particular time points during follow-up. SEV and FFV images were acquired in patients with knee OA. The 81 patients (157 knees) followed up for ≥24 months were selected as study subjects. Medial joint space widths (MJSW), Kellgren–Lawrence (KL) grades, and reductions in MJSW on SEV (ΔSEV) and FFV (ΔFFV) were compared in knees evaluated by SEV and FFV. At both time-points, mean MJSW was significantly lower by FFV than by SEV. Mean MJSW was significantly lower at follow-up than at first examination by both SEV and FFV. At both time-points, the KL grade was higher by FFV than by SEV group. The ΔFFV was significantly greater than the ΔSEV. ΔSEV did not differ significantly among KL grades, but ΔFFV was significantly greater in patients with KL grade II than in patients with other KL grades. FFV is not only useful for evaluating joint space in knees with OA, but also for accurately evaluating the progression of OA. The risk of rapid progression of knee OA may be higher in patients with KL grade II, as determined by FFV. FFV may be superior to SEV in determining appropriate treatment strategies for knee OA. PMID:29245351
Lee, Hyoungwook; Kim, Cheolhee; Song, Jung Han
2015-01-01
The effect of the microstructure heterogeneity on the tensile plastic deformation characteristic of friction-stir-welded (FSW) dual-phase (DP) steel was investigated for the potential applications on the lightweight design of vehicles. Friction-stir-welded specimens with a butt joint configuration were prepared, and quasi-static tensile tests were conducted, to evaluate the tensile properties of DP980 dual-phase steels. The friction-stir welding led to the formation of martensite and a significant hardness rise in the stir zone (SZ), but the presence of a soft zone in the heat-affected zone (HAZ) was caused by tempering of the pre-existing martensite. Owing to the appearance of severe soft zone, DP980 FSW joint showed almost 93% joint efficiency with the view-point of ultimate tensile strength and relatively low ductility than the base metal (BM). The local tensile deformation characteristic of the FSW joints was also examined using the digital image correlation (DIC) methodology by mapping the global and local strain distribution, and was subsequently analyzed by mechanics calculation. It is found that the tensile deformation of the FSW joints is highly heterogeneous, leading to a significant decrease in global ductility. The HAZ of the joints is the weakest region where the strain localizes early, and this localization extends until fracture with a strain near 30%, while the strain in the SZ and BM is only 1% and 4%, respectively. Local constitutive properties in different heterogeneous regions through the friction-stir-welded joint was also briefly evaluated by assuming iso-stress conditions. The local stress-strain curves of individual weld zones provide a clear indication of the heterogeneity of the local mechanical properties. PMID:28793720
Shetty, Gautam M; Mullaji, Arun; Bhayde, Sagar
2012-10-01
This prospective study aimed to evaluate radiographically, change in joint line and femoral condylar offset with the optimized gap balancing technique in computer-assisted, primary, cruciate-substituting total knee arthroplasties (TKAs). One hundred and twenty-nine consecutive computer-assisted TKAs were evaluated radiographically using pre- and postoperative full-length standing hip-to-ankle, antero-posterior and lateral radiographs to assess change in knee deformity, joint line height and posterior condylar offset. In 49% of knees, there was a net decrease (mean 2.2mm, range 0.2-8.4mm) in joint line height postoperatively whereas 46.5% of knees had a net increase in joint line height (mean 2.5mm, range 0.2-11.2mm). In 93% of the knees, joint line was restored to within ± 5 mm of preoperative values. In 53% of knees, there was a net increase (mean 2.9 mm, range 0.2-12 mm) in posterior offset postoperatively whereas 40% of knees had a net decrease in posterior offset (mean 4.2mm, range 0.6-20mm). In 82% of knees, the posterior offset was restored within ± 5 mm of preoperative values. Based on radiographic evaluation in extension and at 30° flexion, the current study clearly demonstrates that joint line and posterior femoral condylar offset can be restored in the majority of computer-assisted, cruciate-substituting TKAs to within 5mm of their preoperative value. The optimized gap balancing feature of the computer software allows the surgeon to simulate the effect of simultaneously adjusting femoral component size, position and distal femoral resection level on joint line and posterior femoral offset. Copyright © 2011 Elsevier B.V. All rights reserved.
Lee, Hyoungwook; Kim, Cheolhee; Song, Jung Han
2015-12-04
The effect of the microstructure heterogeneity on the tensile plastic deformation characteristic of friction-stir-welded (FSW) dual-phase (DP) steel was investigated for the potential applications on the lightweight design of vehicles. Friction-stir-welded specimens with a butt joint configuration were prepared, and quasi-static tensile tests were conducted, to evaluate the tensile properties of DP980 dual-phase steels. The friction-stir welding led to the formation of martensite and a significant hardness rise in the stir zone (SZ), but the presence of a soft zone in the heat-affected zone (HAZ) was caused by tempering of the pre-existing martensite. Owing to the appearance of severe soft zone, DP980 FSW joint showed almost 93% joint efficiency with the view-point of ultimate tensile strength and relatively low ductility than the base metal (BM). The local tensile deformation characteristic of the FSW joints was also examined using the digital image correlation (DIC) methodology by mapping the global and local strain distribution, and was subsequently analyzed by mechanics calculation. It is found that the tensile deformation of the FSW joints is highly heterogeneous, leading to a significant decrease in global ductility. The HAZ of the joints is the weakest region where the strain localizes early, and this localization extends until fracture with a strain near 30%, while the strain in the SZ and BM is only 1% and 4%, respectively. Local constitutive properties in different heterogeneous regions through the friction-stir-welded joint was also briefly evaluated by assuming iso-stress conditions. The local stress-strain curves of individual weld zones provide a clear indication of the heterogeneity of the local mechanical properties.
The use of tibial tuberosity-trochlear groove indices based on joint size in lower limb evaluation.
Ferlic, Peter Wilhelm; Runer, Armin; Dirisamer, Florian; Balcarek, Peter; Giesinger, Johannes; Biedermann, Rainer; Liebensteiner, Michael Christian
2018-05-01
The correlation between tibial tuberosity-trochlear groove distance (TT-TG) and joint size, taking into account several different parameters of knee joint size as well as lower limb dimensions, is evaluated in order to assess whether TT-TG indices should be used in instead of absolute TT-TG values. This study comprised a retrospective analysis of knee CT scans, including 36 cases with patellofemoral instability (PFI) and 30 controls. Besides TT-TG, five measures of knee joint size were evaluated in axial CT slices: medio-lateral femur width, antero-posterior lateral condylar height, medio-lateral width of the tibia, width of the patella and the proximal-distal joint size (TT-TE). Furthermore, the length of the femur, the tibia and the total leg length were measured in the CT scanogram. Correlation analysis of TT-TG and the other parameters was done by calculating the Spearman correlation coefficient. In the PFI group lateral condylar height (r = 0.370), tibia width (r = 0.406) and patella width (r = 0.366) showed significant moderate correlations (p < 0.03) with TT-TG. Furthermore, we found a significant correlation between TT-TG and tibia length (r = 0.371) and total leg length (r = 381). The control group showed no significant correlation between TT-TG and knee joint size or between TT-TG and measures of lower limb length. Tibial tuberosity-trochlear groove distance correlates with several parameters of knee joint size and leg length in patients with patellofemoral instability. Application of indices determining TT-TG as a ratio of joint size could be helpful in establishing the indication for medial transfer of the tibial tuberosity in patients with PFI. Level III.
Omair, Mohammed A; Akhavan, Pooneh; Naraghi, Ali; Mittoo, Shikha; Xiong, Juan; Weber, Deborah; Lin, Daming; Weber, Melissa; Keystone, Edward C
2018-03-01
To describe the dorsal 4-finger technique (DFFT) in examining metacarpophalangeal (MCP) joints of patients with rheumatoid arthritis (RA) and compare it to the traditional 2-finger technique (TFT) using ultrasound (US) as a gold standard. Four rheumatologists evaluated 180 MCP joints of 18 patients with RA. All patients underwent US for greyscale (GSUS) and power Doppler US (PDUS). Agreements between rheumatologists, the 2 techniques, and US were evaluated using Cohen κ and the first-order agreement coefficient (AC1) κ methods. The population comprised 17 females (94.4%) with a mean (SD) age and disease duration of 56.8 (14.4) and 21.8 (12.9) years, respectively. Eight patients (44.4%) were taking methotrexate monotherapy, while 10 patients (55.6%) were receiving biologics. US evaluation revealed 69 (38.3%) and 30 (16.7%) joints exhibited synovitis grade 2-3 by GSUS and PDUS, respectively. Effusion was documented in 30 joints (16.7%). The mean intraobserver agreement using the DFFT and TFT were 80.5% and 86%, respectively. The mean interobserver agreements using the DFFT and TFT were 84% and 74%, respectively. κ agreement with US findings was similar for both techniques in tender joints but was higher for the DFFT in nontender joints (0.33 vs 0.07, p = 0.015 for GSUS) and (0.48 vs 0.11, p = 0.002 for PDUS). The DFFT had a higher sensitivity in detecting ballottement by GSUS (0.47 vs 0.2, p < 0.001) and PDUS (0.60 vs 0.27, p < 0.001). The DFFT is a novel, reproducible, and reliable method to examine MCP joints, and it has a better correlation with US than the traditional TFT.
Geomechanical Response of Jointed Caprock During CO2 Geological Sequestration
NASA Astrophysics Data System (ADS)
Newell, P.; Martinez, M. J.; Bishop, J. E.
2014-12-01
Geological sequestration of CO2 refers to the injection of supercritical CO2 into deep reservoirs trapped beneath a low-permeability caprock formation. Maintaining caprock integrity during the injection process is the most important factor for a successful injection. In this work we evaluate the potential for jointed caprock during injection scenarios using coupled three-dimensional multiphase flow and geomechanics modeling. Evaluation of jointed/fractured caprock systems is of particular concern to CO2 sequestration because creation or reactivation of joints (mechanical damage) can lead to enhanced pathways for leakage. In this work, we use an equivalent continuum approach to account for the joints within the caprock. Joint's aperture and non-linear stiffness of the caprock will be updated dynamically based on the effective normal stress. Effective permeability field will be updated based on the joints' aperture creating an anisotropic permeability field throughout the caprock. This feature would add another coupling between the solid and fluid in addition to basic Terzaghi's effective stress concept. In this study, we evaluate the impact of the joint's orientation and geometry of caprock and reservoir layers on geomechanical response of the CO2 geological systems. This work is supported as part of the Center for Frontiers of Subsurface Energy Security, an Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences under Award Number DE-SC0001114. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.
Ramme, Austin J; Voss, Kevin; Lesporis, Jurinus; Lendhey, Matin S; Coughlin, Thomas R; Strauss, Eric J; Kennedy, Oran D
2017-05-01
MicroCT imaging allows for noninvasive microstructural evaluation of mineralized bone tissue, and is essential in studies of small animal models of bone and joint diseases. Automatic segmentation and evaluation of articular surfaces is challenging. Here, we present a novel method to create knee joint surface models, for the evaluation of PTOA-related joint changes in the rat using an atlas-based diffeomorphic registration to automatically isolate bone from surrounding tissues. As validation, two independent raters manually segment datasets and the resulting segmentations were compared to our novel automatic segmentation process. Data were evaluated using label map volumes, overlap metrics, Euclidean distance mapping, and a time trial. Intraclass correlation coefficients were calculated to compare methods, and were greater than 0.90. Total overlap, union overlap, and mean overlap were calculated to compare the automatic and manual methods and ranged from 0.85 to 0.99. A Euclidean distance comparison was also performed and showed no measurable difference between manual and automatic segmentations. Furthermore, our new method was 18 times faster than manual segmentation. Overall, this study describes a reliable, accurate, and automatic segmentation method for mineralized knee structures from microCT images, and will allow for efficient assessment of bony changes in small animal models of PTOA.
Weichman, B M; Chau, T T; Rona, G
1987-04-01
Histopathologic evaluation of hindpaws from control rats with established adjuvant arthritis showed severe alterations in soft tissue and bone, as well as progressive, moderate-to-severe articular changes. Following treatment with etodolac for 28 days, soft tissue and articular changes were rated mild, and bone changes were rated moderate, but with remodeling. These findings indicate that etodolac partially reversed the joint damage in these rats.
A joint-space numerical model of metabolic energy expenditure for human multibody dynamic system.
Kim, Joo H; Roberts, Dustyn
2015-09-01
Metabolic energy expenditure (MEE) is a critical performance measure of human motion. In this study, a general joint-space numerical model of MEE is derived by integrating the laws of thermodynamics and principles of multibody system dynamics, which can evaluate MEE without the limitations inherent in experimental measurements (phase delays, steady state and task restrictions, and limited range of motion) or muscle-space models (complexities and indeterminacies from excessive DOFs, contacts and wrapping interactions, and reliance on in vitro parameters). Muscle energetic components are mapped to the joint space, in which the MEE model is formulated. A constrained multi-objective optimization algorithm is established to estimate the model parameters from experimental walking data also used for initial validation. The joint-space parameters estimated directly from active subjects provide reliable MEE estimates with a mean absolute error of 3.6 ± 3.6% relative to validation values, which can be used to evaluate MEE for complex non-periodic tasks that may not be experimentally verifiable. This model also enables real-time calculations of instantaneous MEE rate as a function of time for transient evaluations. Although experimental measurements may not be completely replaced by model evaluations, predicted quantities can be used as strong complements to increase reliability of the results and yield unique insights for various applications. Copyright © 2015 John Wiley & Sons, Ltd.
Lee, Hong-Jae; Lim, Kil-Byung; Jung, Tae-Ho; Kim, Dug-Young
2013-01-01
Objective To compare the effect of foot orthotics and rehabilitation exercises by assessing balancing ability and joint proprioception in athletes who have chronic ankle instability. Methods Forty-one athletes who visited hospitals due to chronic ankle instability were randomly assigned to two groups. One group had ankle rehabilitation exercises while the other group had the same rehabilitation exercises as well as foot orthotics. Joint position sense of the ankle joint was examined by using an isokinetic exercise machine. Balancing abilities categorized into static, dynamic and functional balance abilities were evaluated by using computerized posturography. We tested the subjects before and after the four-week rehabilitation program. Results After the four-week treatment, for joint reposition sense evaluation, external 75% angle evaluation was done, revealing that the group with the application of foot orthotics improved by -1.07±1.64 on average, showing no significant difference between the two groups (p>0.05). Static, dynamic and functional balancing abilities using balance masters were evaluated, revealing that the two groups improved in some items, but showing no significant difference between them (p>0.05). Conclusion This study found that athletes with chronic ankle instability who had foot orthotics applied for four weeks improved their proprioceptive and balancing abilities, but did not show additional treatment effects compared with rehabilitation exercise treatment. PMID:24020033
Lee, Hong-Jae; Lim, Kil-Byung; Jung, Tae-Ho; Kim, Dug-Young; Park, Kyung-Rok
2013-08-01
To compare the effect of foot orthotics and rehabilitation exercises by assessing balancing ability and joint proprioception in athletes who have chronic ankle instability. Forty-one athletes who visited hospitals due to chronic ankle instability were randomly assigned to two groups. One group had ankle rehabilitation exercises while the other group had the same rehabilitation exercises as well as foot orthotics. Joint position sense of the ankle joint was examined by using an isokinetic exercise machine. Balancing abilities categorized into static, dynamic and functional balance abilities were evaluated by using computerized posturography. We tested the subjects before and after the four-week rehabilitation program. After the four-week treatment, for joint reposition sense evaluation, external 75% angle evaluation was done, revealing that the group with the application of foot orthotics improved by -1.07±1.64 on average, showing no significant difference between the two groups (p>0.05). Static, dynamic and functional balancing abilities using balance masters were evaluated, revealing that the two groups improved in some items, but showing no significant difference between them (p>0.05). This study found that athletes with chronic ankle instability who had foot orthotics applied for four weeks improved their proprioceptive and balancing abilities, but did not show additional treatment effects compared with rehabilitation exercise treatment.
Competencies Used to Evaluate High School Coaches.
ERIC Educational Resources Information Center
Gratto, John
1983-01-01
Studies of how to evaluate high school coaches' effectiveness found that most respondents felt that principals, athletic directors, and coaches should jointly arrive at a method of evaluation. Coaching competencies rated most highly included prevention and care of athletic injuries, supervision, and consistent discipline. Other valued competencies…
Yamabe, Daisuke; Murakami, Hideki; Chokan, Kou; Endo, Hirooki; Oikawa, Ryosuke; Sawamura, Shoitsu; Doita, Minoru
2017-12-15
T2 mapping was used to quantify the water content of lumbar spine intervertebral discs (IVDs) and facet joints before and after physiological loading. The aim of this study was to clarify the interaction between lumbar spine IVD and facet joints as load-bearing structures by measuring the water content of their matrix after physiological loading using T2 mapping magnetic resonance imaging (MRI). To date, few reports have functionally evaluated lumbar spine IVD and facet joints, and their interaction in vivo. T2 mapping may help detect changes in the water content of IVD and articular cartilage of facet joints before and after physiological loading, thereby enabling the evaluation of changes in interacted water retention between IVD and facet joints. Twenty asymptomatic volunteers (10 female and 10 male volunteers; mean age, 19.3 years; age range, 19-20 years) underwent MRI before and after physiological loading such as lumbar flexion, extension, and rotation. Each IVD from L1/2 to L5/S1 was sliced at center of the disc space, and the T2 value was measured at the nucleus pulposus (NP), anterior annulus fibrosus (AF), posterior AF, and bilateral facet joints. In the NP, T2 values significantly decreased after exercise at every lumbar spinal level. In the anterior AF, there were no significant differences in T2 values at any level. In the posterior AF, T2 values significantly increased only at L4/5. In the bilateral facet joints, T2 values significantly decreased after exercise at every level. There was a significant decrease in the water content of facet joints and the NP at every lumbar spinal level after dynamic loading by physical lumbar exercise. These changes appear to play an important and interactional role in the maintenance of the interstitial matrix in the IVD NP and cartilage in the facet joint. 3.
Krill, Michael K; Rosas, Samuel; Kwon, KiHyun; Dakkak, Andrew; Nwachukwu, Benedict U; McCormick, Frank
2018-02-01
The clinical examination of the shoulder joint is an undervalued diagnostic tool for evaluating acromioclavicular (AC) joint pathology. Applying evidence-based clinical tests enables providers to make an accurate diagnosis and minimize costly imaging procedures and potential delays in care. The purpose of this study was to create a decision tree analysis enabling simple and accurate diagnosis of AC joint pathology. A systematic review of the Medline, Ovid and Cochrane Review databases was performed to identify level one and two diagnostic studies evaluating clinical tests for AC joint pathology. Individual test characteristics were combined in series and in parallel to improve sensitivities and specificities. A secondary analysis utilized subjective pre-test probabilities to create a clinical decision tree algorithm with post-test probabilities. The optimal special test combination to screen and confirm AC joint pathology combined Paxinos sign and O'Brien's Test, with a specificity of 95.8% when performed in series; whereas, Paxinos sign and Hawkins-Kennedy Test demonstrated a sensitivity of 93.7% when performed in parallel. Paxinos sign and O'Brien's Test demonstrated the greatest positive likelihood ratio (2.71); whereas, Paxinos sign and Hawkins-Kennedy Test reported the lowest negative likelihood ratio (0.35). No combination of special tests performed in series or in parallel creates more than a small impact on post-test probabilities to screen or confirm AC joint pathology. Paxinos sign and O'Brien's Test is the only special test combination that has a small and sometimes important impact when used both in series and in parallel. Physical examination testing is not beneficial for diagnosis of AC joint pathology when pretest probability is unequivocal. In these instances, it is of benefit to proceed with procedural tests to evaluate AC joint pathology. Ultrasound-guided corticosteroid injections are diagnostic and therapeutic. An ultrasound-guided AC joint corticosteroid injection may be an appropriate new standard for treatment and surgical decision-making. II - Systematic Review.
Sheahan, Peter J; Cashaback, Joshua G A; Fischer, Steven L
2017-09-01
Background Tree planters are at a high risk for wrist injury due to awkward postures and high wrist loads experienced during each planting cycle, specifically at shovel-ground impact. Wrist joint stiffness provides a measure that integrates postural and loading information. Objective The purpose of this study was to evaluate wrist joint stiffness requirements at the instant of shovel-ground impact during tree planting and determine if a wrist brace could alter muscular contributions to wrist joint stiffness. Method Planters simulated tree planting with and without wearing a brace on their planting arm. Surface electromyography (sEMG) from six forearm muscles and wrist kinematics were collected and used to calculate muscular contributions to joint rotational stiffness about the wrist. Results Wrist joint stiffness increased with brace use, an unanticipated and negative consequence of wearing a brace. As a potential benefit, planters achieved a more neutrally oriented wrist angle about the flexion/extension axis, although a less neutral wrist angle about the ulnar/radial axis was observed. Muscle activity did not change between conditions. Conclusion The joint stiffness analysis, combining kinematic and sEMG information in a biologically relevant manner, revealed clear limitations with the interface between the brace grip and shovel handle that jeopardized the prophylactic benefits of the current brace design. This limitation was not as evident when considering kinematics and sEMG data independently. Application A neuromechanical model (joint rotational stiffness) enhanced our ability to evaluate the brace design relative to kinematic and sEMG parameter-based metrics alone.
Spectrum Management and Electromagnetic Compatibility Issues in the Department of Defense
1991-01-01
Interference JEWC Joint Electronic Warfare Center JRFL Joint Restricted Frequency List JSMS Joint Spectrum Management System JT&E Joint Test and Evaluation JTAC...Joint Restricted Frequency List (JRFL) is essentially a list of frequencies prohibited from use by ECM units. Creation and maintenance of the JRFL to...sponsored by CECOM, developed a prototype that primarily acted as an analysis of the restricted frequency list as a predecessor to DECON. Presently the Army
Stelzeneder, David; Messner, Alina; Vlychou, Marianna; Welsch, Goetz H; Scheurecker, Georg; Goed, Sabine; Pieber, Karin; Pflueger, Verena; Friedrich, Klaus M; Trattnig, Siegfried
2011-11-01
To assess the feasibility of T2 mapping of lumbar facet joints and intervertebral discs in a single imaging slab and to compare the findings with morphological grading. Sixty lumbar spine segments from 10 low back pain patients and 5 healthy volunteers were examined by axial T2 mapping and morphological MRI at 3.0 Tesla. Regions of interest were drawn on a single slice for the facet joints and the intervertebral discs (nucleus pulposus, anterior and posterior annulus fibrosus). The Weishaupt grading was used for facet joints and the Pfirrmann score was used for morphological disc grading ("normal" vs. "abnormal" discs). The inter-rater agreement was excellent for the facet joint T2 evaluation (r = 0.85), but poor for the morphological Weishaupt grading (kappa = 0.15). The preliminary results show similar facet joint T2 values in segments with normal and abnormal Pfirrmann scores. There was no difference in mean T2 values between facet joints in different Weishaupt grading groups. Facet joint T2 values showed a weak correlation with T2 values of the posterior annulus (r = 0.32) This study demonstrates the feasibility of a combined T2 mapping approach for the facet joints and intervertebral discs using a single axial slab.
Scaddan, Emma; Rowell, John; O'Leary, Shaun
2017-09-01
Arthritis resulting from recurrent intra-articular bleeding in individuals with hemophilia can be severely debilitating due to joint pain and stiffness with subsequent loss of mobility and function. Very limited studies have investigated the potential benefits of joint mobilization for this condition. This case series is a preliminary investigation of safety, as well as immediate and short-term clinical benefits, associated with gentle knee and ankle joint mobilization in people with hemophilic arthropathy. A single intervention of joint mobilization was applied to the affected knees and/or ankles of 16 individuals with severe or moderate hemophilia within a public hospital setting. Adverse events, as well as immediate (pain-free passive joint range, Timed Up and Go Test with maximum pain numerical rating scale) and short-term (Lower Extremity Functional Scale) effects of the intervention were evaluated with a repeated measures ANOVA. There were no adverse events. An immediate significant increase was observed in pain-free passive ankle joint range of motion ( p < 0.05) following the joint mobilization intervention. The findings of this case series suggest that gentle joint mobilization techniques may be safely considered as part of a multimodal management approach for hemophilic arthropathy.
Wegener, Veronika; Jorysz, Gabriele; Arnoldi, Andreas; Utzschneider, Sandra; Wegener, Bernd; Jansson, Volkmar; Heimkes, Bernhard
2017-03-01
Evaluation of hip joint space width during child growth is important to aid in the early diagnosis of hip pathology in children. We established reference values for hip joint space and femoral head size for each age. Hip joint space development during growth was retrospectively investigated medial and cranial in 1350 hip joints of children using standard anteroposterior supine plain pelvic radiographs. Maximum capital femoral epiphysis diameter and femoral radii were further more investigated. Hip joint space values show a slow decline during growth. Joint space was statistically significantly (p < 0.006) larger in boys than girls. Our hip joint space measurements on supine subjects seem slightly larger than those reported by Hughes on standing subjects. Evaluation of the femoral head diameter and the radii showed a size curve quite parallel to the known body growth charts. Radii medial and perpendicular to the physis are not statistically significantly different. We recommend to compare measurements of hip joint space at two locations to age dependent charts using the same imaging technique. During growth, a divergence in femoral head size from the expected values or loss of the spherical shape should raise the question of hip disorder. Clin. Anat. 30:267-275, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Gupta, R. K.; Anil Kumar, V.; Panicker, Paul G.
2016-02-01
Joining of thin sheets (0.5 mm) of stainless steel 304 and 17-4PH through resistance spot welding is highly challenging especially when joint is used for high temperature applications. Various combinations of stainless steel sheets of thickness 0.5 mm are spot welded and tested at room temperature as well as at high temperatures (800 K, 1,000 K, 1,200 K). Parent metal as well as spot welded joints are tested and characterized. It is observed that joint strength of 17-4PH steel is highest and then dissimilar steel joint of 17-4PH with SS-304 is moderate and of SS-304 is lowest at all the temperatures. Joint strength of 17-4PH steel is found to be >80% of parent metal properties up to 1,000 K then drastic reduction in strength is noted at 1,200 K. Gradual reduction in strength of SS-304 joint with increase in temperature from 800 to 1,200 K is noted. At 1,200 K, joint strength of all combinations of joints is found to be nearly same. Microstructural evaluation of weld nugget after testing at different temperatures shows presence of tempered martensite in 17-4PH containing welds and homogenized structure in stainless steel 304 weld.
Resealing concrete pavement joints
DOT National Transportation Integrated Search
1999-07-01
The primary objective of this study was to evaluate the relative performance of the selected joint sealant materials. Other objectives were to determine the effect of selected sealant configurations and installation methods, and to identify sealant m...
Longitudinal Joint Construction Techniques for Asphalt Pavements
DOT National Transportation Integrated Search
1997-08-01
Thirty hot mix asphalt (HMA) test sections were constructed in Michigan (1992), Wisconsin (1992), Colorado (1994), and Pennsylvania (1995) to evaluate the effectiveness of twelve different longitudinal joint construction techniques. The performance o...
Design and simulation of a cable-pulley-based transmission for artificial ankle joints
NASA Astrophysics Data System (ADS)
Liu, Huaxin; Ceccarelli, Marco; Huang, Qiang
2016-06-01
In this paper, a mechanical transmission based on cable pulley is proposed for human-like actuation in the artificial ankle joints of human-scale. The anatomy articular characteristics of the human ankle is discussed for proper biomimetic inspiration in designing an accurate, efficient, and robust motion control of artificial ankle joint devices. The design procedure is presented through the inclusion of conceptual considerations and design details for an interactive solution of the transmission system. A mechanical design is elaborated for the ankle joint angular with pitch motion. A multi-body dynamic simulation model is elaborated accordingly and evaluated numerically in the ADAMS environment. Results of the numerical simulations are discussed to evaluate the dynamic performance of the proposed design solution and to investigate the feasibility of the proposed design in future applications for humanoid robots.
[Microcirculatory investigations in hemophilia patients].
Davydkin, I L; Kosiakova, Iu A
2012-01-01
to evaluate microcirculation (MC) and its influencing factors in hemophilia patients. In 44 hemophilia patients with recurrent hemarthrosis, laser Doppler flowmetry was used to evaluate resting MC above the index fingers, knee and ankle joints during an occlusion test, with allowance made for muscle and adipose tissue mass. The increased perfusion value above the afflicted joints was found to correspond to the phase of an exacerbation of posthemorrhagic inflammation and to be a risk factor of recurrent hemarrthrosis. Analysis of the occlusion test above the knee joints and index fingers revealed a diminished MC reserve and a tendency to precapillary spasm. MC changes were more pronounced in a shortage of muscle and adipose tissue mass. Hemophilia patients must regularly do physical exercises to make skeletal muscles develop well in order to prevent an exacerbation of the joint inflammatory process.
Synovitis induced by joint lavage with hypertonic saline solutions in healthy dairy calves
Achard, Damien; Francoz, David; Desrochers, André; Girard, Christiane; Piché, Caroline
2012-01-01
The objective of this study was to evaluate the effect of a single joint lavage with 7.2% or 15% hypertonic saline solutions (HSS) on the tarsocrural joints of healthy calves. The tarsi of 10 calves were randomly lavaged with 7.2% HSS, 15% HSS, or isotonic saline. Synovial fluid samples were collected aseptically on days 1 (before joint lavage), 2, 3, 4, and 8 for complete cytological analysis. Lameness, joint swelling, and pain were recorded daily. Calves were euthanized on day 8 for gross and histological analyses of synovial membranes and articular cartilage. Synovitis was evaluated using a scoring system reflecting inflammatory changes in synovial membranes. Joints irrigated with HSS were more distended and painful compared with isotonic control joints. Swelling decreased consistently in the joints lavaged with 7.2% HSS, whereas it remained unchanged in joints lavaged with 15% HSS. Slight to moderate lameness was observed in the joints lavaged with 15% HSS. In comparison to isotonic saline joints, total protein concentration was significantly increased on day 2 and 3 for the joints lavaged with 7.2% HSS (P ≤ 0.01) and on days 2, 3, and 4 in the joints lavaged with 15% HSS (P ≤ 0.0006). Gross and histological findings revealed that synovitis was more severe in the joints lavaged with 15% HSS but variable in the joints lavaged with 7.2% HSS. No significant differences were observed for the articular cartilage. Fifteen percent HSS is not recommended for joint lavage. Although irrigation with 7.2% HSS may induce a variable synovitis, it was found appropriate for joint lavage. Its effects on septic joints remain undetermined. PMID:23024450
Early detection and progression of decay in L-joints and lap-joints in a moderate decay hazard zone
Carol A. Clausen; Terry L. Highley; Daniel L. Lindner
2006-01-01
Accelerated test methods are needed to evaluate the initiation and progression of decay in wood exposed aboveground. The relationship between test conditions and initiation of decay, however, is poorly understood. Southern pine and maple L-joints and lap-joints were exposed aboveground in a configuration that encouraged water entrapment at the Valley View Experimental...
Ethical Challenges Scenario: Youth Involvement in Evaluation
ERIC Educational Resources Information Center
Cooksy, Leslie J.
2007-01-01
All evaluators face the challenge of striving to adhere to the highest possible standards of ethical conduct. Translating the AEA's Guiding Principles and the Joint Committee's Program Evaluation Standards into everyday practice, however, can be a complex, uncertain, and frustrating endeavor. Moreover, acting in an ethical fashion can require…
ERIC Educational Resources Information Center
Holland, Patricia
2005-01-01
Despite the concerns of scholars in the field of instructional supervision, teacher evaluations continue to emphasize bureaucratic accountability and standardization. This article presents an argument for extending the Joint Committee on Standards' Personnel Evaluation Standards to include standards related to the practice of supervision. The…
Summary of 2008 CUAA Chinese University Evaluation and Research Report
ERIC Educational Resources Information Center
Deguo, Zhao; Yanhou, Cai; Yongjun, Feng; Lingfeng, Wang
2009-01-01
Since 2002, the University Evaluation Task Force of China University Alumni Association Network (CUAA), "University Weekly" and "21st Century Talent Report" have made joint efforts in the evaluation of higher education institutions in China. Compared with the ranking in 2007, China's University Ranking in the 2008 report is…
An Eastern Paradigm of Evaluation
ERIC Educational Resources Information Center
Russon, Craig
2008-01-01
Teaching on the philosophies of evaluation as part of a pilot introductory course of a new diploma programme jointly sponsored by the United Nations (UN) Evaluation Group and the United Nations Staff College, the author compared and contrasted the "rationalistic" paradigm with the "naturalistic" paradigm on the basis of ontology, epistemology, and…
DOT National Transportation Integrated Search
2008-05-01
This document describes the hydrogen transit bus evaluations performed by the National Renewable Energy Laboratory (NREL) and funded by the U.S. Department of Energy (DOE) and the U.S. Department of Transportations Federal Transit Administration (...
An Information Search Model of Evaluative Concerns in Intergroup Interaction
ERIC Educational Resources Information Center
Vorauer, Jacquie D.
2006-01-01
In an information search model, evaluative concerns during intergroup interaction are conceptualized as a joint function of uncertainty regarding and importance attached to out-group members' views of oneself. High uncertainty generally fosters evaluative concerns during intergroup exchanges. Importance depends on whether out-group members'…
NASA Astrophysics Data System (ADS)
Lee, H.
2016-12-01
Precipitation is one of the most important climate variables that are taken into account in studying regional climate. Nevertheless, how precipitation will respond to a changing climate and even its mean state in the current climate are not well represented in regional climate models (RCMs). Hence, comprehensive and mathematically rigorous methodologies to evaluate precipitation and related variables in multiple RCMs are required. The main objective of the current study is to evaluate the joint variability of climate variables related to model performance in simulating precipitation and condense multiple evaluation metrics into a single summary score. We use multi-objective optimization, a mathematical process that provides a set of optimal tradeoff solutions based on a range of evaluation metrics, to characterize the joint representation of precipitation, cloudiness and insolation in RCMs participating in the North American Regional Climate Change Assessment Program (NARCCAP) and Coordinated Regional Climate Downscaling Experiment-North America (CORDEX-NA). We also leverage ground observations, NASA satellite data and the Regional Climate Model Evaluation System (RCMES). Overall, the quantitative comparison of joint probability density functions between the three variables indicates that performance of each model differs markedly between sub-regions and also shows strong seasonal dependence. Because of the large variability across the models, it is important to evaluate models systematically and make future projections using only models showing relatively good performance. Our results indicate that the optimized multi-model ensemble always shows better performance than the arithmetic ensemble mean and may guide reliable future projections.
Osteoarthritis of the distal interphalangeal joint.
Kaufmann, Robert A; Lögters, Tim T; Verbruggen, Gust; Windolf, Joachim; Goitz, Robert J
2010-12-01
Osteoarthritis occurs with the highest prevalence in the distal interphalangeal joint of the hand and has been divided into an erosive and a nonerosive form. The pathogenesis of the early stages of osteoarthritis is poorly understood, but considerable emphasis has been placed on the role of cartilage and subchondral bone as well as soft tissue structures such as collateral ligaments and tendons. Radiographic evaluation represents the most standardized method to quantify disease progression, with different systems having been developed for defining and grading radiographic features. This current concepts article examines the recent knowledge base regarding the etiology, pathogenesis, and evaluation of osteoarthritis of the distal interphalangeal joint. Copyright © 2010. Published by Elsevier Inc.
Marine Corps Research and Development Objectives Document (RADOD)
1980-08-08
461.1 Data exchange /joint projects, evaluation of foreign weapon systems .......................... N/A MANAGEMENT SUPPORT 471.0 General management...DI3ZITiL WIDEBAND TtAMSISSION ;YSTem W2AK D~ CQ)43L CCC 9S22 AUTOMATED DATA ENTlY SYSTEM (AES) usM: CCC 9269 ORMBDAND 3MNDIRE:TID04AL VHF 4NTEM44...Standardization and Interoper- ability through data exchanges , joint projects, evaluation of foreign weapon systems , material or related technology. 461.0
NASA Technical Reports Server (NTRS)
Taylor, G. R.; Rogers, T. D.; Brower, M. E.; Kropp, K.
1976-01-01
Two joint inflight biomedical experiments were conducted during the unique Apollo-Soyuz Test Project (ASTP) spaceflight. One experiment evaluated rhythmicity of spore production of Streptomyces levoris. The other evaluated components of the infectious disease process by measuring alteration in: (1) the composition of the microbial population inhabiting USA and USSR crewmembers and spacecraft; (2) the ability of each crewmember's defense mechanism to resist infection; and (3) the ability of certain microorganisms to originate infections. These two experiments are described and the major results discussed.
Subchondral bone density distribution of the talus in clinically normal Labrador Retrievers.
Dingemanse, W; Müller-Gerbl, M; Jonkers, I; Vander Sloten, J; van Bree, H; Gielen, I
2016-03-15
Bones continually adapt their morphology to their load bearing function. At the level of the subchondral bone, the density distribution is highly correlated with the loading distribution of the joint. Therefore, subchondral bone density distribution can be used to study joint biomechanics non-invasively. In addition physiological and pathological joint loading is an important aspect of orthopaedic disease, and research focusing on joint biomechanics will benefit veterinary orthopaedics. This study was conducted to evaluate density distribution in the subchondral bone of the canine talus, as a parameter reflecting the long-term joint loading in the tarsocrural joint. Two main density maxima were found, one proximally on the medial trochlear ridge and one distally on the lateral trochlear ridge. All joints showed very similar density distribution patterns and no significant differences were found in the localisation of the density maxima between left and right limbs and between dogs. Based on the density distribution the lateral trochlear ridge is most likely subjected to highest loads within the tarsocrural joint. The joint loading distribution is very similar between dogs of the same breed. In addition, the joint loading distribution supports previous suggestions of the important role of biomechanics in the development of OC lesions in the tarsus. Important benefits of computed tomographic osteoabsorptiometry (CTOAM), i.e. the possibility of in vivo imaging and temporal evaluation, make this technique a valuable addition to the field of veterinary orthopaedic research.
Dua, R; Nandlal, B
2004-03-01
The present study was conducted to compare and evaluate the tensile strength of silver soldered joints of stainless steel and cobalt-chromium orthodontic wires with band material. An attempt was made to observe the effect of joint site preparation by incorporation of tack welding and increasing metal to metal surface contact area by flattening an end of the wire prior to soldering along with the regularly used round wires without tack welding. A total of 180 wire specimens were soldered to 180 band specimens. Fifteen samples according to joint site preparation were included for each of the wire groups i.e. Gloria (S.S.), Remanium (S.S.) and Remaloy (Co-Cr) wires of 0.036" in diameter. The findings of the study were suggestive that all three wires may be used for preparing silver soldered joints irrespective of the quality of the wire. However, when subjecting the wire to joint site preparation, Gloria (S.S.) wire showed less tensile strength as compared to Remanium and Remaloy.
QM-8 final performance evaluation report: SEALS, volume 4
NASA Technical Reports Server (NTRS)
Nelsen, L. V.
1989-01-01
The Space Shuttle Redesigned Solid Rocket Motor (RSRM) static test of Qualification Motor-8 (QM-8) was conducted. The QM-8 test article was the fifth full-scale, full-duration test, and the third qualification motor to incorporate the redesigned case field joint and nozzle-to-case joint. This was the second static test conducted in the T-97 test facility, which is equipped with actuators for inducing external side loads to a 360 degree external tank (ET) attach ring during test motor operation, and permits heating/cooling of an entire motor. The QM-8 motor was cooled to a temperature which ensured that the maximum propellant mean bulk temperature (PMBT) of 40 F was achieved at firing. All test results are not included, but rather, the performance of the metal case, field joints, and nozzle-to-case joint is addressed. The involvement is studied of the Structural Applications and Structural Design Groups with the QM-8 test which includes: assembly procedures of the field and nozzle-to-case joints, joint leak check results, structural test results, and post-test inspection evaluations.
Luckasson, Ruth; Ford, Marty E; McMillan, Elise D; Misilo, Frederick M; Nygren, Margaret A
2017-07-01
The American Association on Intellectual and Developmental Disabilities (AAIDD) and The Arc of the United States (The Arc) have a long history of joined efforts to develop, express, and evaluate disability policies. These efforts have resulted in a series of formal statements on critical issues such as education, healthcare, human rights, and criminal justice. Their joint efforts further important policy goals including providing clear strong communication about important policy values and directions, promulgating key principles of high quality supports and services, affirming best professional practices, and emphasizing personal outcomes. In addition, the joint efforts (a) affirm important aspects of organization identity; (b) enhance the organizations' abilities to assure the input of a wide variety of perspectives; (c) engage members' expanded ranges of experiences and talents; (d) multiply staff and leadership resources; (e) increase communication strength and avenues; and (f) establish processes for timely review and revision of policies as critical disability issues arise or change, and new opportunities for policy integration and advancement occur. This article describes the processes used to develop, express, and evaluate the position statements; summarizes the policy content of several joint statements; and discusses the role of these organization position statements.
Design, fabrication and test of graphite/polymide composite joints and attachments: Summary
NASA Technical Reports Server (NTRS)
Cushman, J. B.; Mccleskey, S. F.; Ward, S. H.
1983-01-01
The design, analysis and testing performed to develop four types of graphite/polyimide (Gr/PI) bonded and bolted composite joints for lightly loaded control surfaces on advanced space transportation systems that operate at temperatures up to 561K (550 F) are summarized. Material properties and 'small specimen' tests were conducted to establish design data and to evaluate specific design details. 'Static discriminator' tests were conducted on preliminary designs to verify structural adequacy. Scaled up specimens of the final joint designs, representative of production size requirements, were subjected to a series of static and fatigue tests to evaluate joint strength. Effects of environmental conditioning were determined by testing aged (125 hours 589K (600 F)) and thermal cycled (116K to 589K (-250 F to 600 F), 125 times) specimens. It is concluded Gr/PI joints can be designed and fabricated to carry the specified loads. Test results also indicate a possible resin loss or degradation of laminates after exposure to 589K (600 F) for 125 hours.
NASA Technical Reports Server (NTRS)
Cushman, J. B.; Mccleskey, S. F.; Ward, S. H.
1982-01-01
The design, analysis, and testing performed to develop four types of graphite/polyimide (Gr/PI) bonded and bolted composite joints for lightly loaded control surfaces on advanced space transportation systems that operate at temperatures up to 561 K (550 F) are summarized. Material properties and small specimen tests were conducted to establish design data and to evaluate specific design details. Static discriminator tests were conducted on preliminary designs to verify structural adequacy. Scaled up specimens of the final joint designs, representative of production size requirements, were subjected to a series of static and fatigue tests to evaluate joint strength. Effects of environmental conditioning were determined by testing aged (125 hours at 589 K (600 F)) and thermal cycled (116 K to 589 K (-250 F to 600 F), 125 times) specimens. It is concluded Gr/PI joints can be designed and fabricated to carry the specified loads. Test results also indicate a possible resin loss or degradation of laminates after exposure to 589 K (600 F) for 125 hours.
Lin, Mau-Chin; Lin, Sheng-Chieh; Wang, Yu-Tsai; Hu, Suh-Woan; Lee, Tzu-Hsin; Chen, Li-Kai; Huang, Her-Hsiung
2007-05-01
The purpose of this study was to evaluate the fracture resistance of Nd:YAG laser-welded cast titanium (Ti) joints with various clinical thicknesses and welding pulse energies. A four-point bending test was used to assess the effects of various specimen thicknesses (1-3 mm) and welding pulse energies (11-24 J) on the fracture resistance of Nd:YAG laser-welded Ti dental joints. Fracture resistance was evaluated in terms of the ratio of the number of fractured specimens to the number of tested specimens. As for the fracture frequencies, they were compared using the Cochran-Mantel-Haenszel test. Morphology of the fractured Ti joints was observed using a scanning electron microscope. Results showed that decreasing the specimen thickness and/or increasing the welding pulse energy, i.e., increasing the welded area percentage, resulted in an increase in the fracture resistance of the Ti joint. Where fracture occurred, the fracture site would be at the center of the weld metal.
NASA Astrophysics Data System (ADS)
You, Taehoon; Kim, Yunsung; Kim, Jina; Lee, Jaehong; Jung, Byungwook; Moon, Jungtak; Choe, Heeman
2009-03-01
Despite being expensive and time consuming, board-level drop testing has been widely used to assess the drop or impact resistance of the solder joints in handheld microelectronic devices, such as cellphones and personal digital assistants (PDAs). In this study, a new test method, which is much simpler and quicker, is proposed. The method involves evaluating the elastic strain energy and relating it to the impact resistance of the solder joint by considering the Young’s modulus of the bulk solder and the fracture stress of the solder joint during a ball pull test at high strain rates. The results show that solder joints can be ranked in order of descending elastic strain energy as follows: Sn-37Pb, Sn-1Ag-0.5Cu, Sn-3Ag-0.5Cu, and Sn-4Ag-0.5Cu. This order is consistent with the actual drop performances of the samples.
Ultrasound-Guided Steroid Injection of the Pisotriquetral Joint: A Multidisciplinary Effort.
Brose, Steven W; Montfort, Janel; Gustafson, Kenneth J; Mittebrun, Ionica; Gauriloff, Samantha; Mosher, Mary; Bourbeau, Dennis J
2017-12-01
From the perspective of a multidisciplinary team, the authors describe the first reported use of ultrasound guidance for steroid injection into the pisotriquetral joint to relieve wrist pain of a person with spinal cord injury undergoing acute inpatient rehabilitation. Musculoskeletal ultrasound guidance was used to improve the accuracy of a corticosteroid injection of the pisotriquetral joint and the basal thumb in a 70-year-old man with paraplegia experiencing multifocal degenerative wrist pain. There was no bleeding or bruising after the injections, and the patient reported complete pain resolution 1 wk after the injections, which continued for over 1 yr. A multidisciplinary team was key in diagnosis, selection of treatment, and evaluation of treatment effect. Corticosteroid injection of the pisotriquetral joint under ultrasound guidance can be used as a treatment modality for managing wrist pain stemming from that joint. Further investigation and studies evaluating the use of ultrasound versus other imaging modalities for injection of the wrist are indicated.
Flight motor set 360L001 (STS-26R). Volume 1: System overview, revision A
NASA Technical Reports Server (NTRS)
Garecht, Diane M.
1990-01-01
The NASA space shuttle flight STS-26R, launched at 11:37.00.009 am, EDT on 29 Sep. 1988, used the redesigned solid rocket motors (RSRM) 360L001A and 360L001B. Evaluation of the ground environment instrumentation (GEI) data recorded prior to flight showed no launch commit criteria violations; that the field joint heater and aft skirt thermal conditioning systems performed adequately; and that the GEI data showed good agreement with thermal model predictions. Evaluation of the developmental flight instrumentation (DFI) revealed excellent agreement with both the predicted and required ballistic specifications. All parameters were well within the GEI specification requirements including propellant burn rates, specific impulse values, and thrust imbalance. Recorded strain values also indicated satisfactory radial growth and stress levels, as well as verification of adequate safety factors. Postflight inspection of the insulation, seals, case, and nozzles showed overall excellent performance. Some thermal DFI protective cork was missing, and inoperative field joint vent valves on the thermal protection cork allowed water entry into the field joints upon splashdown. Evaluation of these anomalies, as well as complete evaluation of all Redesigned Solid Rocket Motor components, is contained.
Flight motor set 360L001 (STS-26R), volume 1
NASA Technical Reports Server (NTRS)
Ricks, Glen A.
1988-01-01
The NASA space shuttle flight STS-26R, launched at 11:37.00.009 a.m. EDT on 29 Sep. 1988, used the redesigned solid rocket motors (RSRM) 360LOO1A and 360LOO1B. Evaluation of the ground environment instrumentation (GEI) data recorded prior to flight showed: (1) no launch commit criteria violations, (2) that the field joint heater and aft skirt thermal conditioning systems performed adequately, and (3) that the GEI data showed good agreement with thermal model predictions. Evaluation of the developmental flight instrumentation (DFI) revealed excellent agreement with both the predicted and required ballistic specifications. All parameters were well within the CEI specification requirements including propellant burn rates, specific impulse values, and thrust imbalance. Recorded strain values also indicated satisfactory radial growth and stress levels, as well as verification of adequate safety factors. Postflight inspection of the insulation, seals, case, and nozzles showed overall excellent performance. Some thermal DFI protective cork was missing, and inoperative field joint vent valves on the thermal protection cork allowed water entry into the field joints upon splashdown. Evaluation of these anomalies, as well as complete evaluation of all RSRM components, is presented.
Biomechanical testing simulation of a cadaver spine specimen: development and evaluation study.
Ahn, Hyung Soo; DiAngelo, Denis J
2007-05-15
This article describes a computer model of the cadaver cervical spine specimen and virtual biomechanical testing. To develop a graphics-oriented, multibody model of a cadaver cervical spine and to build a virtual laboratory simulator for the biomechanical testing using physics-based dynamic simulation techniques. Physics-based computer simulations apply the laws of physics to solid bodies with defined material properties. This technique can be used to create a virtual simulator for the biomechanical testing of a human cadaver spine. An accurate virtual model and simulation would complement tissue-based in vitro studies by providing a consistent test bed with minimal variability and by reducing cost. The geometry of cervical vertebrae was created from computed tomography images. Joints linking adjacent vertebrae were modeled as a triple-joint complex, comprised of intervertebral disc joints in the anterior region, 2 facet joints in the posterior region, and the surrounding ligament structure. A virtual laboratory simulation of an in vitro testing protocol was performed to evaluate the model responses during flexion, extension, and lateral bending. For kinematic evaluation, the rotation of motion segment unit, coupling behaviors, and 3-dimensional helical axes of motion were analyzed. The simulation results were in correlation with the findings of in vitro tests and published data. For kinetic evaluation, the forces of the intervertebral discs and facet joints of each segment were determined and visually animated. This methodology produced a realistic visualization of in vitro experiment, and allowed for the analyses of the kinematics and kinetics of the cadaver cervical spine. With graphical illustrations and animation features, this modeling technique has provided vivid and intuitive information.
Waldenmeier, Leonie; Evers, Christoph; Uder, Michael; Janka, Rolf; Hennig, Frank Friedrich; Pachowsky, Milena Liese; Welsch, Götz Hannes
2018-02-01
Objective To evaluate and characterize the appearance of articular cartilage in the tibiofemoral joint of young professional soccer players using T2-relaxation time evaluation on magnetic resonance imaging (MRI). Design In this study, we included 57 male adolescents from the youth academy of a professional soccer team. The MRI scans were acquired of the knee joint of the supporting leg. An "early unloading" (minute 0) and "late unloading" (minute 28) T2-sequence was included in the set of images. Quantitative T2-analysis was performed in the femorotibial joint cartilage in 4 slices with each 10 regions of interest (ROIs). Statistical evaluation, using Wilcoxon signed-rank tests, was primarily performed to compare the T2 values of the "early unloading" and "late unloading." Results When comparing "early unloading" with "late unloading," our findings showed a significant increase of T2-relaxation times in the weightbearing femoral cartilage of the medial ( P < 0.001) and lateral ( P < 0.001) compartment of the knee and in the tibial cartilage of the medial compartment ( P < 0.001). Conclusion In this study, alterations of the cartilage were found with a maximum in the medial condyle where the biomechanical load of the knee joint is highest, as well as where most of the chronic cartilage lesions occur. To avoid chronic damage, special focus should be laid on this region.
Testaverde, Lorenzo; Perrone, Anna; Caporali, Laura; Ermini, Antonella; Izzo, Luciano; D'Angeli, Ilaria; Impara, Luca; Mazza, Dario; Izzo, Paolo; Marini, Mario
2011-06-01
To compare Computed Tomography (CT) and Magnetic Resonance (MR) features and their diagnostic potential in the assessment of Synovial Chondromatosis (SC) of the Temporo-Mandibular Joint (TMJ). Eight patients with symptoms and signs compatible with dysfunctional disorders of the TMJ underwent CT and MR scan. We considered the following parameters: soft tissue involvement (disk included), osteostructural alterations of the joints, loose bodies and intra-articular fluid. These parameters were evaluated separately by two radiologists with a "double blinded method" and then, after agreement, definitive assessment of the parameters was given. CT and MR findings were compared. Histopathological results showed metaplastic synovia in all patients and therefore confirmed diagnosis of SC. MR resulted better than CT in the evaluation of all parameters except the osteostructural alterations of the joints, estimated with more accuracy by CT scan. CT scan is excellent to define bony surfaces of the articular joints and flogistic tissue but it fails in the detection of loose bodies when these are not yet calcified. MR scan therefore is the gold standard when SC is suspected since it can visualize loose bodies at early stage and also evaluate disk condition and eventual extra-articular tissues involvement. The use of T2-weighted images and contrast medium allows identifying intra-articular fluid, estimating its entity and discriminating from sinovial tissue. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
Program Evaluation of Outcomes Based Orthotic and Prosthetic Education
2006-12-01
Rheumatoid Arthritis; synovial joints ; tendon sheaths. b. Osteoarthritis; weight bearing joints ; loading areas. c. Osteoporosis; cancellous bone...flexion. 32. The desirable length of a thumb post is: a. to the thumb IP joint . b. proximal to the IP joint . c. to the nail bed. d. just...assist hyperextension of the thoracic spine. b. eliminate motion. c. prevent lumbar flexion. d. reduce axial load on lumbar vertebrae. 44
Pictorial review: MRI of the sternum and sternoclavicular joints.
Aslam, M; Rajesh, A; Entwisle, J; Jeyapalan, K
2002-07-01
The sternum and sternoclavicular joints are difficult to evaluate with plain radiographs. The value of CT in assessing lesions of the sternum and sternoclavicular joints has been well documented, but the potential role of MRI has not been emphasized. We present the MRI techniques, normal appearances and a spectrum of abnormalities, and emphasize the role of MRI as a useful radiological investigation for the sternum and sternoclavicular joints.
Designs and performance of three new microprocessor-controlled knee joints.
Thiele, Julius; Schöllig, Christina; Bellmann, Malte; Kraft, Marc
2018-02-09
A crossover design study with a small group of subjects was used to evaluate the performance of three microprocessor-controlled exoprosthetic knee joints (MPKs): C-Leg 4, Plié 3 and Rheo Knee 3. Given that the mechanical designs and control algorithms of the joints determine the user outcome, the influence of these inherent differences on the functional characteristics was investigated in this study. The knee joints were evaluated during level-ground walking at different velocities in a motion analysis laboratory. Additionally, technical analyses using patents, technical documentations and X-ray computed tomography (CT) for each knee joint were performed. The technical analyses showed that only C-Leg 4 and Rheo Knee 3 allow microprocessor-controlled adaptation of the joint resistances for different gait velocities. Furthermore, Plié 3 is not able to provide stance extension damping. The biomechanical results showed that only if a knee joint adapts flexion and extension resistances by the microprocessor all known advantages of MPKs can become apparent. But not all users may benefit from the examined functions: e.g. a good accommodation to fast walking speeds or comfortable stance phase flexion. Hence, a detailed comparison of user demands and performance of the designated knee joint is mandatory to ensure a maximum in user outcome.
Evaluation of experimental transection and partial excision of the caudal cruciate ligament in dogs.
Harari, J; Johnson, A L; Stein, L E; Kneller, S K; Pijanowski, G
1987-01-01
The caudal cruciate ligament (CaCL) of one stifle joint in seven dogs was transected and a 2 to 4 mm section was removed. Six months after surgery, none of the dogs were lame. Thigh muscle circumference, stifle range of motion, and internal tibial rotation in the operated limb were not significantly different from the preoperative measurements or the contralateral, unoperated limb. A caudal drawer motion was consistently present in the stifle joints with a transected CaCL. A radiographic evaluation of the operated stifle joints did not reveal osteoarthritic changes; four of seven stifle joints had an irregular fat pad 6 months after surgery. Results of a joint fluid analysis revealed a slight increase in synovial cells within treated stifle joints; inflammatory cells were not observed. The only gross morphologic change in stifle joints with a severed ligament was enlarged knobby remnants of the CaCL. Articular cartilage defects or osteophytes were not observed. Results of a histologic examination of the CaCL remnants revealed synovial cellular capping and intraligamentous fibroplasia. Based on a limited number of dogs, it was concluded that isolated transection of the CaCL produced minimal clinical and pathologic changes in the stifle joint during a 6 month period.
Fjordbakk, Cathrine T; Haga, Henning A
2011-06-01
To assess the efficacy of a commercially available topical vapocoolant spray in reducing responses to arthrocentesis of the middle carpal (MC) and metacarpophalangeal (MCP) joints and jugular vein catheterization in unsedated horses. 8 healthy research horses. Arthrocentesis of both MC and MCP joints and bilateral jugular vein catheterization were performed in each horse. Immediately prior to skin penetration, 1 randomly selected MC joint, MCP joint, and jugular vein were sprayed with a vapocoolant liquid (intervention product), and the contralateral MC joint, MCP joint, and jugular vein were sprayed with water (placebo). An observer blinded to the type of spray treatment used evaluated the horses' responses to needle or catheter placement procedures by use of a 6-point categorical scale and a 100-mm visual analog scale. Responses evaluated via the visual analog scale were significantly reduced after application of the intervention product, compared with responses after application of the placebo, for the MC and MCP joints; no difference in responses to jugular vein catheterization was detected between the 2 treatments. Vapocoolant spray was safe and effective in reducing horses' responses to arthrocentesis. The use of such products prior to joint injections may reduce procedural nociception and pain anticipation in unsedated horses and may improve the safety of personnel performing such procedures.
NASA Technical Reports Server (NTRS)
Russell, C. K.; Malone, T. W.; Cato, S. N.
2004-01-01
The international space welding experiment was designed to evaluate the universal handtool (UHT) functions as a welding, brazing, coating, and cutting tool for in-space operations. The UHT is an electron beam welding system developed by the Paton Welding Institute (PWI), Kiev, Ukraine, and operated a 8 kV with up to 1 kW of power. In preparation for conducting the space welding experiment, cosmonauts were trained to properly operate the UHT and correctly process samples. This Technical Memorandum presents the results of the destructive and nondestructive evaluation of the training samples made in Russia in 1998. It was concluded that acceptable welds can be made with the UHT despite the constraints imposed by a space suit. The lap joint fillet weld configuration was more suitable than the butt joint configuration for operators with limited welding experience. The tube braze joint configuration designed by the PWI was easily brazed in a repeatable manner.
Williams, Devin M; Miller, Andy O; Henry, Michael W; Westrich, Geoffrey H; Ghomrawi, Hassan M K
2017-09-01
The risk of prosthetic joint infection increases with Staphylococcus aureus colonization. The cost-effectiveness of decolonization is controversial. We evaluated cost-effectiveness decolonization protocols in high-risk arthroplasty patients. An analytical model evaluated risk under 3 protocols: 4 swabs, 2 swabs, and nasal swab alone. These were compared to no-screening and universal decolonization strategies. Cost-effectiveness was evaluated from the hospital, patient, and societal perspective. Under base case conditions, universal decolonization and 4-swab strategies were most effective. The 2-swab and universal decolonization strategy were most cost-effective from patient and societal perspectives. From the hospital perspective, universal decolonization was the dominant strategy (much less costly and more effective). S aureus decolonization may be cost-effective for reducing prosthetic joint infections in high-risk patients. These results may have important implications for treatment of patients and for cost containment in a bundled payment system. Copyright © 2017 Elsevier Inc. All rights reserved.
Wear Distribution Detection of Knee Joint Prostheses by Means of 3D Optical Scanners
Affatato, Saverio; Valigi, Maria Cristina; Logozzo, Silvia
2017-01-01
The objective of this study was to examine total knee polyethylene inserts from in vitro simulation to evaluate and display—using a 3D optical scanner—wear patterns and wear rates of inserts exposed to wear by means of simulators. Various sets of tibial inserts have been reconstructed by using optical scanners. With this in mind, the wear behavior of fixed and mobile bearing polyethylene knee configurations was investigated using a knee wear joint simulator. After the completion of the wear test, the polyethylene menisci were analyzed by an innovative 3D optical scanners in order to evaluate the 3D wear distribution on the prosthesis surface. This study implemented a new procedure for evaluating polyethylene bearings of joint prostheses obtained after in vitro wear tests and the proposed new approach allowed quantification of the contact zone on the geometry of total knee prostheses. The results of the present study showed that mobile TKPs (total knee prosthesis) have lower wear resistance with respect to fixed TKPs. PMID:28772725
Analysis of Knee Joint Line Obliquity after High Tibial Osteotomy.
Oh, Kwang-Jun; Ko, Young Bong; Bae, Ji Hoon; Yoon, Suk Tae; Kim, Jae Gyoon
2016-11-01
The aim of this study was to evaluate which lower extremity alignment (knee and ankle joint) parameters affect knee joint line obliquity (KJLO) in the coronal plane after open wedge high tibial osteotomy (OWHTO). Overall, 69 knees of patients that underwent OWHTO were evaluated using radiographs obtained preoperatively and from 6 weeks to 3 months postoperatively. We measured multiple parameters of knee and ankle joint alignment (hip-knee-ankle angle [HKA], joint line height [JLH], posterior tibial slope [PS], femoral condyle-tibial plateau angle [FCTP], medial proximal tibial angle [MPTA], mechanical lateral distal femoral angle [mLDFA], KJLO, talar tilt angle [TTA], ankle joint obliquity [AJO], and the lateral distal tibial ground surface angle [LDTGA]; preoperative [-pre], postoperative [-post], and the difference between -pre and -post values [-Δ]). We categorized patients into two groups according to the KJLO-post value (the normal group [within ± 4 degrees, 56 knees] and the abnormal group [greater than ± 4 degrees, 13 knees]), and compared their -pre parameters. Multiple logistic regression analysis was used to examine the contribution of the -pre parameters to abnormal KJLO-post. The mean HKA-Δ (-9.4 ± 4.7 degrees) was larger than the mean KJLO-Δ (-2.1 ± 3.2 degrees). The knee joint alignment parameters (the HKA-pre, FCTP-pre) differed significantly between the two groups ( p < 0.05). In addition, the HKA-pre (odds ratio [OR] = 1.27, p = 0.006) and FCTP-pre (OR = 2.13, p = 0.006) were significant predictors of abnormal KJLO-post. However, -pre ankle joint parameters (TTA, AJO, and LDTGA) did not differ significantly between the two groups and were not significantly associated with the abnormal KJLO-post. The -pre knee joint alignment and knee joint convergence angle evaluated by HKA-pre and FCTP-pre angle, respectively, were significant predictors of abnormal KJLO after OWHTO. However, -pre ankle joint parameters were not significantly associated with abnormal KJLO after OWHTO. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Stock, J D; Calderón Díaz, J A; Rothschild, M F; Mote, B E; Stalder, K J
2018-06-09
Feet and legs of replacement females were objectively evaluated at selection, i.e. approximately 150 days of age (n=319) and post first parity, i.e. any time after weaning of first litter and before 2nd parturition (n=277) to 1) compare feet and leg joint angle ranges between selection and post first parity; 2) identify feet and leg joint angle differences between selection and first three weeks of second gestation; 3) identify feet and leg join angle differences between farms and gestation days during second gestation; and 4) obtain genetic variance components for conformation angles for the two time points measured. Angles for carpal joint (knee), metacarpophalangeal joint (front pastern), metatarsophalangeal joint (rear pastern), tarsal joint (hock), and rear stance were measured using image analysis software. Between selection and post first parity significant differences were observed for all joints measured (P < 0.05). Knee, front and rear pastern angles were less (more flexion), and hock angles were greater (less flexion) as age progressed (P < 0.05), while the rear stance pattern was less (feet further under center) at selection than post first parity (only including measures during first three weeks of second gestation). Only using post first parity leg conformation information, farm was a significant source of variation for front and rear pasterns and rear stance angle measurements (P < 0.05). Knee angle was less (more flexion) (P < 0.05) as gestation age progressed. Heritability estimates were low to moderate (0.04 - 0.35) for all traits measured across time points. Genetic correlations between the same joints at different time points were high (> 0.8) between the front leg joints and low (<0.2) between the rear leg joints. High genetic correlations between time points indicate that the trait can be considered the same at either time point, and low genetic correlations indicate that the trait at different time points should be considered as two separate traits. Minimal change in the front leg suggests conformation traits that remain between selection and post first parity, while larger changes in rear leg indicate that rear leg conformation traits should be evaluated at multiple time periods.
Relevance of adjacent joint imaging in the evaluation of ankle fractures.
Antoci, Valentin; Patel, Shaun P; Weaver, Michael J; Kwon, John Y
2016-10-01
Routinely obtaining adjacent joint radiographs when evaluating patients with ankle fractures may be of limited clinical utility and an unnecessary burden, particularly in the absence of clinical suspicion for concomitant injuries. One thousand, three hundred and seventy patients who sustained ankle fractures over a 5-year period presenting to two level 1 trauma centers were identified. Medical records were retrospectively reviewed for demographics, physical examination findings, and radiographic information. Analyses included descriptive statistics along with sensitivity and predictive value calculations for the presence of adjacent joint fracture. Adjacent joint imaging (n=1045 radiographs) of either the knee or foot was obtained in 873 patients (63.7%). Of those, 75/761 patients (9.9%) demonstrated additional fractures proximal to the ankle joint, most commonly of the proximal fibula. Twenty-two of 284 (7.7%) demonstrated additional fractures distal to the ankle joint, most commonly of the metatarsals. Tenderness to palpation demonstrated sensitivities of 0.92 and 0.77 and positive predictive values of 0.94 and 0.89 for the presence of proximal and distal fractures, respectively. Additionally, 19/22 (86.4%) of patients sustaining foot fractures had their injury detectable on initial ankle X-rays. Overall, only 5.5% (75/1370) of patients sustained fractures proximal to the ankle and only 0.2% (3/1370) of patients had additional foot fractures not evident on initial ankle X-rays. The addition of adjacent joint imaging for the evaluation of patients sustaining ankle fractures is low yield. As such, patient history, physical examination, and clinical suspicion should direct the need for additional X-rays. Level IV. Copyright © 2016 Elsevier Ltd. All rights reserved.
Vairis, Achilles; Stefanoudakis, George; Petousis, Markos; Vidakis, Nectarios; Tsainis, Andreas-Marios; Kandyla, Betina
2016-02-01
The human knee joint has a three-dimensional geometry with multiple body articulations that produce complex mechanical responses under loads that occur in everyday life and sports activities. Understanding the complex mechanical interactions of these load-bearing structures is of use when the treatment of relevant diseases is evaluated and assisting devices are designed. The anterior cruciate ligament (ACL) in the knee is one of four main ligaments that connects the femur to the tibia and is often torn during sudden twisting motions, resulting in knee instability. The objective of this work is to study the mechanical behavior of the human knee joint and evaluate the differences in its response for three different states, i.e., intact, ACL-deficient, and surgically treated (reconstructed) knee. The finite element models corresponding to these states were developed. For the reconstructed model, a novel repair device was developed and patented by the author in previous work. Static load cases were applied, as have already been presented in a previous work, in order to compare the calculated results produced by the two models the ACL-deficient and the surgically reconstructed knee joint, under the exact same loading conditions. Displacements were calculated in different directions for the load cases studied and were found to be very close to those from previous modeling work and were in good agreement with experimental data presented in literature. The developed finite element model for both the intact and the ACL-deficient human knee joint is a reliable tool to study the kinematics of the human knee, as results of this study show. In addition, the reconstructed human knee joint model had kinematic behavior similar to the intact knee joint, showing that such reconstruction devices can restore human knee stability to an adequate extent.
Fujita, Yukihiro; Hara, Yasushi; Nezu, Yoshinori; Yamaguchi, Shinya; Schulz, Kurt S; Tagawa, Masahiro
2005-12-01
To compare activities of interleukin (IL)-1beta, IL-6, tumor necrosis factor (TNF)-alpha, and matrix metalloproteinase (MMP)-3 and contents of sulfated glycosaminoglycan (S-GAG) in joint fluid obtained from dogs with hip dysplasia (HD) and clinically normal dogs, evaluate correlations among these markers in joint fluid obtained from dogs with HD, and evaluate correlations between each marker and clinical and radiographic variables. Animals-26 dogs with HD (clinical group) and 43 clinically normal Beagles (control group). Joint fluid was aseptically collected from the hip joints of all dogs. For each dog in the clinical group, age, duration of lameness, radiographic osteoarthritis (OA) score, and Norberg angle in each affected joint were recorded. Activities of IL-1beta, IL-6, TNF-alpha, and MMP-3 and S-GAG contents were measured. Values were compared between groups by use of Mann-Whitney U tests, and the Spearman rank correlation test was used to evaluate correlations among markers and between each marker and clinical or radiographic variables. Values of all markers were significantly higher for the clinical group, compared with values for the control group. There was a moderate positive correlation between lameness duration and IL-6 activity and a strong negative correlation between the Norberg angle and IL-1beta activity. Analysis of our results indicated that there was a significant increase in markers of OA in dogs with HD. Activities of IL-1beta and IL-6 in joint fluid of dogs with HD may be influenced by the severity of laxity in the hip joint and lameness duration, respectively.
MiBLSi Program Evaluation of Participatory Elementary Schools from 2003-2009
ERIC Educational Resources Information Center
Gibbs, Marvin
2012-01-01
This dissertation details the use of the Program Evaluations Metaevaluation Checklist (PEMC), Stufflebeam, 1999, which is for performing final, summative metaevaluations. It is organized according to the Joint Committee Program Evaluation Standards. For each of the 30 standards the checklist includes 6 checkpoints drawn from the substance of the…
ERIC Educational Resources Information Center
Evaluation and Training Inst., Los Angeles, CA.
Twenty-one California career-vocational educational articulation projects, commonly referred to as 2 + 2 partnerships, were jointly funded across the 1986-89 funding period and third-party evaluations were conducted in 1988-89. The longitudinal study examined the long-term effects of the original partnerships. Evaluators formed an advisory…
Evaluating the Effectiveness Of Postfire Rehabilitation Treatments
Peter R. Robichaud; Jan L. Beyers; Daniel G. Neary
2000-01-01
Spending on postfire emergency watershed rehabilitation has increased during the past decade. A west-wide evaluation of USDA Forest Service burned area emergency rehabilitation (BAER) treatment effectiveness was undertaken as a joint project by USDA Forest Service Research and National Forest System staffs. This evaluation covers 470 fires and 321 BAER projects, from...
Evaluating the effectiveness of postfire rehabilitation treatments
Peter R. Robichaud; Jan L. Beyers; Daniel G. Neary
2000-01-01
Spending on postfire emergency watershed rehabilitation has increased during the past decade. A west-wide evaluation of USDA Forest Service burned area emergency rehabilitation (BAER) treatment effectiveness was undertaken as a joint project by USDA Forest Service Research and National Forest System staffs. This evaluation covers 470 fires and 321 BAER projects, from...
Study of the Peak Shear Strength of a Cement-Filled Hard Rock Joint
NASA Astrophysics Data System (ADS)
She, Cheng-Xue; Sun, Fu-Ting
2018-03-01
The peak shear strength of a cement-filled hard rock joint is studied by theoretical analysis and laboratory testing. Based on the concept of the shear resistance angle, by combining the statistical method and fractal theory, three new parameters are proposed to characterize the three-dimensional joint morphology, reflecting the effects of the average roughness, multi-scale asperities and the dispersion degree of the roughness distribution. These factors are independent of the measurement scale, and they reflect the anisotropy of the joint roughness. Compressive shear tests are conducted on cement-filled joints. Because joints without cement can be considered special cement-filled joints in which the filling degree of cement is zero, they are also tested. The cement-filled granite joint fails primarily along the granite-cement interfaces. The filling degree of cement controls the joint failure and affects its mechanical behaviour. With a decrease in the filling degree of cement, the joint cohesion decreases; however, the dilatancy angle and the basic friction angle of the interface increase. As the filling degree approaches zero, the cohesion approaches zero, while the dilatancy angle and the basic friction angle increase to those of the joint without cement. A set of formulas is proposed to evaluate the peak shear strength of the joints with and without cement. The formulas are shown to be reasonable by comparison with the tested peak shear strength, and they reflect the anisotropy of the strength. This research deepens the understanding of cement-filled joints and provides a method to evaluate their peak shear strength.
de Bruin, Tanya; de Rooster, Hilde; van Bree, Henri; Cox, Eric
2007-03-01
To evaluate anticollagen type I antibodies in synovial fluid of the affected stifle joint, the contralateral stifle joint, and the left shoulder joint of dogs with unilateral cranial cruciate ligament (CrCL) rupture during an extended period of 12 to 18 months. 13 client-owned dogs with CrCL rupture and 2 sham-operated dogs. All dogs were examined and arthrocentesis of all 3 joints was performed every 6 months after surgery. Synovial fluid samples were tested for anticollagen type I antibodies by use of an ELISA. Dogs with partial CrCL rupture had higher antibody titers than dogs with complete rupture. Six of 13 dogs ruptured the contralateral CrCL during the study, whereby higher antibody titers were found for the stifle joints than for the shoulder joint. Seronegative dogs or dogs with extremely low antibody titers and 2 dogs with high antibody titers did not sustain a CrCL rupture in the contralateral stifle joint. In most dogs that had a CrCL rupture of the contralateral stifle joint, a distinct antibody titer gradient toward the stifle joints was detected, suggesting that there was a local inflammatory process in these joints. However, only a small number of sham-operated dogs were used to calculate the cutoff values used to determine the anticollagen type I antibody titers in these patients. Synovial fluid antibodies against collagen type I alone do not initiate CrCL rupture because not all dogs with high antibody titers sustained a CrCL rupture in the contralateral stifle joint.
Evaluation of longitudinal construction joints on traffic operations and safety.
DOT National Transportation Integrated Search
2009-01-01
Motorists generally follow the guidance provided by pavement markings, which are normally marked in : coincidence with the longitudinal construction joints, when the markings are necessary. At some locations, : however, there may be a difference betw...
Alternative Fuel Vehicle (AFV) Infrastructure Incentives Study The Georgia Joint Alternative Fuels Infrastructure Study Committee evaluated how providing market incentives for AFV fueling infrastructure may lead . For more information, see the Joint Study Committee
Evaluation of transverse joint forming methods for PCC pavement.
DOT National Transportation Integrated Search
2006-01-01
The members of the Iowa Concrete Paving Association, the National Concrete Pavement Technology Center Research Committee, and : the Iowa Highway Research Board commissioned a study to examine alternative ways of developing transverse joints in portla...
Evaluation of Silicone as an Artificial Lubricant in Osteoarthrotic Joints
Wright, V.; Haslock, D. I.; Dowson, D.; Seller, P. C.; Reeves, B.
1971-01-01
Silicone 300 has been evaluated as an artificial lubricant in osteoarthrotic joints by means of a pilot study in five inpatients and a control trial of 25 outpatients with 40 osteoarthrotic knees. Sequential analysis showed a significant benefit from saline compared with silicone at one week follow-up and no significant difference at one month. Measurement of stiffness with a knee arthrograph showed no difference in reduction of stiffness between the two substances. In a study of 18 rabbits there was no evidence that silicone was retained in the joint cavity for longer than 48 hours. There was a failure of clearance of iodinated serum albumin for as long as three to four days after the injection of silicone, suggesting some obstruction to lymphatic outflow. Experimentally produced cartilaginous defects did not heal quicker with the injection of silicone into the joint. PMID:5575973
Robust tuning of robot control systems
NASA Technical Reports Server (NTRS)
Minis, I.; Uebel, M.
1992-01-01
The computed torque control problem is examined for a robot arm with flexible, geared, joint drive systems which are typical in many industrial robots. The standard computed torque algorithm is not directly applicable to this class of manipulators because of the dynamics introduced by the joint drive system. The proposed approach to computed torque control combines a computed torque algorithm with torque controller at each joint. Three such control schemes are proposed. The first scheme uses the joint torque control system currently implemented on the robot arm and a novel form of the computed torque algorithm. The other two use the standard computed torque algorithm and a novel model following torque control system based on model following techniques. Standard tasks and performance indices are used to evaluate the performance of the controllers. Both numerical simulations and experiments are used in evaluation. The study shows that all three proposed systems lead to improved tracking performance over a conventional PD controller.
Semevolos, Stacy A; Reed, Shannon K
2011-04-01
To evaluate molecular and histologic characteristics of the superficial digital flexor tendon (SDFT), deep digital flexor tendon (DDFT), and suspensory ligament (SL) and assess trace-mineral concentrations in serum, liver, and hair of juvenile llamas with metacarpophalangeal and metatarsophalangeal joint hyperextension. 12 juvenile llamas (6 with bilateral hyperextension of metacarpophalangeal joints, metatarsophalangeal joints, or both and 6 clinically normal control llamas). Radiography and ultrasonography of metacarpophalangeal and metatarsophalangeal regions were performed. Llamas were euthanized, and SDFT, DDFT, and SL samples were collected for histologic evaluation of collagen and elastin content and orientation, proteoglycan content, and collagen type III immunohistochemistry. Total RNA was isolated from SL tissue, and gene expression of collagen types I and III, lysyl oxidase, and matrix metalloproteinase-13 was evaluated via real-time quantitative reverse transcriptase PCR assay. Liver, serum, and hair samples were evaluated for trace mineral content. Collagen type III gene expression and proteoglycan content were significantly increased in SL samples of affected juvenile llamas, compared with those of control llamas. No difference was detected in collagen and elastin content and orientation or in gene expression of collagen type I, lysyl oxidase, or matrix metalloproteinase-13 between groups. Affected llamas had significantly increased serum molybdenum and decreased liver cobalt concentrations, compared with values for control llamas. Increased collagen type III gene expression and proteoglycan content in SL samples of affected juvenile llamas provided evidence of ongoing SL matrix repair. Trace mineral differences may have been attributable to dietary imbalances in affected llamas.
Peng, Qiyu; Park, Hyung-Soon; Shah, Parag; Wilson, Nicole; Ren, Yupeng; Wu, Yi-Ning; Liu, Jie; Gaebler-Spira, Deborah J; Zhang, Li-Qun
2011-01-01
Spasticity and contracture are major sources of disability in people with neurological impairments that have been evaluated using various instruments: the Modified Ashworth Scale, tendon reflex scale, pendulum test, mechanical perturbations, and passive joint range of motion (ROM). These measures generally are either convenient to use in clinics but not quantitative or they are quantitative but difficult to use conveniently in clinics. We have developed a manual spasticity evaluator (MSE) to evaluate spasticity/contracture quantitatively and conveniently, with ankle ROM and stiffness measured at a controlled low velocity and joint resistance and Tardieu catch angle measured at several higher velocities. We found that the Tardieu catch angle was linearly related to the velocity, indicating that increased resistance at higher velocities was felt at further stiffer positions and, thus, that the velocity dependence of spasticity may also be position-dependent. This finding indicates the need to control velocity in spasticity evaluation, which is achieved with the MSE. Quantitative measurements of spasticity, stiffness, and ROM can lead to more accurate characterizations of pathological conditions and outcome evaluations of interventions, potentially contributing to better healthcare services for patients with neurological disorders such as cerebral palsy, spinal cord injury, traumatic brain injury, and stroke.
2005 Precision Strike Winter Roundtable
2005-01-26
Lamartin Director Enterprise Development Developmental Test & Evaluation Assessments & Support System Engineering Mr. Schaeffer Director 6 6 Systems and...Joint Concept Development , by Colonel Ed Yarnell, USMC USJFCOM’s Experimentation Strategy, by Captain E. Mark Chicoine, USN Systems and Mission...Strategy Division Chief, J-5 Strategic Plans and Policy Directorate, The Joint Staff 1030 JOINT CONCEPT DEVELOPMENT : Ed Yarnell, USMC Chief, Concepts
The Unified Classification System (UCS): improving our understanding of periprosthetic fractures.
Duncan, C P; Haddad, F S
2014-06-01
Periprosthetic fractures are an increasingly common complication following joint replacement. The principles which underpin their evaluation and treatment are common across the musculoskeletal system. The Unified Classification System proposes a rational approach to treatment, regardless of the bone that is broken or the joint involved. ©2014 The British Editorial Society of Bone & Joint Surgery.
[Arthroscopic repair of meniscus injury with Fast-fix under local anesthesia].
Wang, Jiang-tao; Liu, Yu-jie; Wang, Jun-liang; Qu, Feng; Yuan, Bang-tuo; Zhao, Gang; Shen, Xue-zhen; Zhu, Juan-li; Liu, Yang
2014-08-01
To evaluate the clinical outcome of arthroscopic repair method of meniscus injury with Fast-fix under local anesthesia. From October 2005 to September 2012,106 patients with meniscus injuries admitted into our - hospital were studied, including 74 males and 32 females, ranging in age from 13 to 71 years old, averaged 27.6 years old. The duration of the disease ranged from 15 days to 5 years. The main clinical manifestations included knee joint pain after exercise, joint locking, pressing pain of knee joint and positive McMurray signs. The MRI showed meniscus tear or degeneration. Arthroscopic repairing surgeries were performed with Fast-fix under local anesthesia. Each patient was assessed with VAS pain evaluation and Lysholm knee-joint score system before and after operation. All the patients were followed up more than 1 year. One hundred and 2 patients were followed up by recording subjective symptoms, clinical examinations and questions naires for an average of 2.6 years (ranged, 1.1 to 8 years), and 4 patients lost follow-up. All the 102 patients had no anesthetic complications. Ninety-six patients had normal subjective symptom and clinical examinations. Four patients had a mild ache with activities,2 patients had moderate pain after activities with joint space pressing pain. VAS pain evaluation and Lysholm knee-joint score after operation both were much better than that before operation. onclusion: Local anesthesia can provide nice circumstances for surgeries. Arthroscopic repair using Fast-fix is an idea method for meniscus injury, especially for the posterior horn tear of medial meniscus, which is simple and convenient with less complications, and satisfactory results.
Haemophilia Joint Health Score in healthy adults playing sports.
Sluiter, D; Foppen, W; de Kleijn, P; Fischer, K
2014-03-01
To evaluate outcome of prophylactic clotting factor replacement in children with haemophilia, the Haemophilia Joint Health Score (HJHS) was developed aiming at scoring early joint changes in children aged 4-18. The HJHS has been used for adults on long-term prophylaxis but interpretation of small changes remains difficult. Some changes in these patients may be due to sports-related injuries. Evaluation of HJHS score in healthy adults playing sports could improve the interpretation of this score in haemophilic patients. The aim of this study was to evaluate the HJHS scores in a cohort of young, healthy men participating in sports. Concomitant with a project collecting MRI images of ankles and knees in normal young adults, HJHS scores were assessed in 30 healthy men aged 18-26, participating in sports one to three times per week. One physiotherapist assessed their clinical function using the HJHS 2.1. History of joint injuries was documented. MRI images were scored by a single radiologist, using the International Prophylaxis Study Group additive MRI score. Median age of the study group was 24.3 years (range 19.0-26.4) and median frequency of sports activities was three times per week (range 1-4). Six joints (five knees, one ankle) had a history of sports-related injury. The median overall HJHS score was 0 out of 124 (range 0-3), with 60% of subjects showing no abnormalities on HJHS. All joints were normal on MRI. These results suggest that frequent sports participation and related injuries are not related with abnormalities in HJHS scores. © 2013 John Wiley & Sons Ltd.
SUPERFUND INNOVATIVE TECHNOLOGY EVALUATION (SITE) PROGRAM ANNUAL REPORT TO CONGRESS 2003
The Superfund Innovative Technology Evaluation (SITE) Program has successfully promoted the development, commercialization and implementation of innovative hazardous waste treatment technologies for 17 years. SITE offers a mechanism for conducting joint technology demonstration a...
Product evaluation : Dow Corning 888
DOT National Transportation Integrated Search
1986-07-10
This report contains a product evaluation of Dow Corning 888 joint sealant. Dow Corning 888 is a one-part silicone material that cures to a low modulus silicone rubber upon exposure to atmospheric moisture. Its uses include transverse and longitudina...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-23
... a qualified practitioner examine each patient before surgery to evaluate the risk of anesthesia. To... requirement that a qualified practitioner must evaluate each patient for proper anesthesia recovery before...
The Superfund Innovative Technology Evaluation Program Annual Report to Congress FY2004
The Superfund Innovative Technology Evaluation (SITE) Program has successfully promoted the development, commercialization, and implementation of innovative hazardous waste treatment technologies for 18 years. SITE offers a mechanism for conducting joint technology demonstration ...
Sawada, Kunihiko; Amemiya, Toshihiko; Hirai, Shigenori; Hayashi, Yusuke; Suzuki, Toshihiro; Honda, Masahiko; Sisounthone, Johnny; Matsumoto, Kunihito; Honda, Kazuya
2018-01-01
We compared the diagnostic reliability of 3.0-T magnetic resonance imaging (MRI) for detection of osseous abnormalities of the temporomandibular joint (TMJ) with that of the gold standard, cone-beam computed tomography (CBCT). Fifty-six TMJs were imaged with CBCT and MRI, and images of condyles and fossae were independently assessed for the presence of osseous abnormalities. The accuracy, sensitivity, and specificity of 3.0-T MRI were 0.88, 1.0, and 0.73, respectively, in condyle evaluation and 0.91, 0.75, and 0.95 in fossa evaluation. The McNemar test showed no significant difference (P > 0.05) between MRI and CBCT in the evaluation of osseous abnormalities in condyles and fossae. The present results indicate that 3.0-T MRI is equal to CBCT in the diagnostic evaluation of osseous abnormalities of the mandibular condyle.
NASA Astrophysics Data System (ADS)
Wunderlich, Adam; Goossens, Bart
2014-03-01
The majority of the literature on task-based image quality assessment has focused on lesion detection tasks, using the receiver operating characteristic (ROC) curve, or related variants, to measure performance. However, since many clinical image evaluation tasks involve both detection and estimation (e.g., estimation of kidney stone composition, estimation of tumor size), there is a growing interest in performance evaluation for joint detection and estimation tasks. To evaluate observer performance on such tasks, Clarkson introduced the estimation ROC (EROC) curve, and the area under the EROC curve as a summary figure of merit. In the present work, we propose nonparametric estimators for practical EROC analysis from experimental data, including estimators for the area under the EROC curve and its variance. The estimators are illustrated with a practical example comparing MRI images reconstructed from different k-space sampling trajectories.
Evaluation of body posture in individuals with internal temporomandibular joint derangement.
Munhoz, Wagner Cesar; Marques, Amélia Pasqual; de Siqueira, José Tadeu Tesseroli
2005-10-01
Temporomandibular dysfunctions (TMD) comprise a great number of disruptions that may affect the temporomandibular joint (TMJ), the masticatory muscles, or both. TMJ internal derangement is a specific type of TMD, of which the etiology and physiopathology are broadly unknown, but have been suggested to be linked to head, neck, and body posture factors. This study aimed at verifying possible relationships between body posture and TMJ internal derangements (TMJ-id), by comparing 30 subjects presenting typical TMJ-id signs to 20 healthy subjects. Subjects' clinical evaluations included anamnesis, stomatognatic system evaluation, and plotting analysis on body posture photographs. No statistically significant differences were found between the groups. Results do not support the assertion that body posture plays a role in causing or enhancing TMD; however, these results should be cautiously considered because of the small number of subjects evaluated and the many posture variables submitted to statistical procedures that lead to high standard deviations.
Rollick, Natalie C; Lemmex, Devin B; Ono, Yohei; Reno, Carol R; Hart, David A; Lo, Ian KY; Thornton, Gail M
2018-01-01
Background When considering the “joint as an organ”, the tissues in a joint act as complementary components of an organ, and the “set point” is the cellular activity for homeostasis of the joint tissues. Even in the absence of injury, joint tissues have adaptive responses to processes, like aging and menopause, which result in changes to the set point. Purpose The purpose of this study in a preclinical model was to investigate age-related and menopause-related changes in knee-joint tissues with the hypothesis that tissues will change in unique ways that reflect their differing contributions to maintaining joint function (as measured by joint laxity) and the differing processes of aging and menopause. Methods Rabbit knee-joint tissues from three groups were evaluated: young adult (gene expression, n=8; joint laxity, n=7; water content, n=8), aging adult (gene expression, n=6; joint laxity, n=7; water content, n=5), and menopausal adult (gene expression, n=8; joint laxity, n=7; water content, n=8). Surgical menopause was induced with ovariohysterectomy surgery and gene expression was assessed using reverse-transcription quantitative polymerase chain reaction. Results Aging resulted in changes to 37 of the 150 gene–tissue combinations evaluated, and menopause resulted in changes to 39 of the 150. Despite the similar number of changes, only eleven changes were the same in both aging and menopause. No differences in joint laxity were detected comparing young adult rabbits with aging adult rabbits or with menopausal adult rabbits. Conclusion Aging and menopause affected the gene-expression patterns of the tissues of the knee joint differently, suggesting unique changes to the set point of the knee. Interestingly, aging and menopause did not affect knee-joint laxity, suggesting that joint function was maintained, despite changes in gene expression. Taken together, these findings support the theory of the joint as an organ where the tissues of the joint adapt to maintain joint function. PMID:29535510
Akerblom, S; Sjöström, L
2007-01-01
Forty-two dogs with lameness emanating from the shoulder joint were studied by clinical examination, radiographic examination, joint fluid analysis, and arthroscopic examination, following a set protocol. Dogs with mild clinical signs, absent or mild radiographic signs of osteoarthrosis, and without or with very mild changes in the synovial fluid, may still have moderate to severe degenerative pathological changes in the shoulder joint.
Centerline (longitudinal) joint adhesive performance : two to three-year review.
DOT National Transportation Integrated Search
2009-11-01
This report discusses preliminary evaluations of adhesive use along longitudinal paving : joints on hot mix asphalt pavements to help prevent longitudinal cracking. Seven : pavements where adhesive was applied to the vertical or sloped face of the fi...
An evaluation of bridge deck joint sealing systems in Virginia.
DOT National Transportation Integrated Search
2003-01-01
The design and fabrication of bridge expansion joint (or movement) systems comprise a rapidly evolving industry. New designs are constantly being presented for trial, often on a piecemeal basis. Occasionally, failures of products occur without suffic...
Silva Rodrigues, João Francisco; Silva E Silva, Cristiane; França Muniz, Thayanne; de Aquino, Alana Fernanda; Neuza da Silva Nina, Larissa; Fialho Sousa, Nagila Caroline; Nascimento da Silva, Luis Claudio; de Souza, Breno Glaessner Gomes Fernandes; da Penha, Tatiana Aranha; Abreu-Silva, Ana Lúcia; de Sá, Joicy Cortez; Soares Fernandes, Elizabeth; Grisotto, Marcos Augusto Grigolin
2018-04-24
Rheumatoid arthritis (RA) is characterized by inflammation of one or more joints, and affects ~1% of the adult population worldwide. Sulforaphane (SFN) is a natural compound that has been suggested as an antioxidant. Here, SFN’s effects were evaluated in a murine mono-arthritis model. Mono-arthritis was induced in mice by a single intra-articular injection of Complete Freund’s Adjuvant (CFA-10 µg/joint, in 10 µL) into the ipsilateral joint. The contralateral joint received an equal volume of PBS. On the 4th day post-joint inflammation induction, animals received either SFN (10 mg/kg) or vehicle (3% DMSO in saline), intraperitoneally (i.p.), twice a day for 3 days. Joint swelling and secondary mechanical allodynia and hyperalgesia were evaluated over 7 days post-CFA. After this period, animals were culled and their blood and synovial fluid samples were collected for analysis of cell populations, cytokine release and thioredoxin reductase (TrxR) activity. Knee joint samples were also collected for histology. SFN reduced joint swelling and damage whilst increasing the recruitment of Ly6C⁺ and Ly6G⁺ cells to CFA-injected joints. SFN-treated animals presented down-regulation of CD11b and CD62L on synovial fluid Ly6G⁺ cells. Synovial fluid samples obtained from CFA-injected joints and plasma samples of SFN-treated mice presented higher levels of IL-6 and increased activity of TrxR, in comparison with controls. These results indicate that SFN reduces knee joint damage by modulating cell activation/migration to the joints, cytokine production and increasing the activity of TrxR, and therefore, may represent an alternative treatment to joint inflammation.
An anatomically based protocol for the description of foot segment kinematics during gait.
Leardini, A; Benedetti, M G; Catani, F; Simoncini, L; Giannini, S
1999-10-01
To design a technique for the in vivo description of ankle and other foot joint rotations to be applied in routine functional evaluation using non-invasive stereophotogrammetry. Position and orientation of tibia/fibula, calcaneus, mid-foot, 1st metatarsal and hallux segments were tracked during the stance phase of walking in nine asymptomatic subjects. Rigid clusters of reflective markers were used for foot segment pose estimation. Anatomical landmark calibration was applied for the reconstruction of anatomical landmarks. Previous studies have analysed only a limited number of joints or have proposed invasive techniques. Anatomical landmark trajectories were reconstructed in the laboratory frame using data from the anatomical calibration procedure. Anatomical co-ordinate frames were defined using the obtained landmark trajectories. Joint co-ordinate systems were used to calculate corresponding joint rotations in all three anatomical planes. The patterns of the joint rotations were highly repeatable within subjects. Consistent patterns between subjects were also exhibited at most of the joints. The method proposed enables a detailed description of ankle and other foot joint rotations on an anatomical base. Joint rotations can therefore be expressed in the well-established terminology necessary for their clinical interpretation. Functional evaluation of patients affected by foot diseases has recently called for more detailed and non-invasive protocols for the description of foot joint rotations during gait. The proposed method can help clinicians to distinguish between normal and pathological pattern of foot joint rotations, and to quantitatively assess the restoration of normal function after treatment.
NASA Astrophysics Data System (ADS)
Wu, Zhixiong; Huang, Rongjin; Huang, ChuanJun; Yang, Yanfang; Huang, Xiongyi; Li, Laifeng
2017-12-01
The Glass-fiber reinforced plastic (GFRP) fabricated by the vacuum bag process was selected as the high voltage electrical insulation and mechanical support for the superconducting joints and the current leads for the ITER Feeder system. To evaluate the cryogenic mechanical properties of the GFRP, the mechanical properties such as the short beam strength (SBS), the tensile strength and the fatigue fracture strength after 30,000 cycles, were measured at 77K in this study. The results demonstrated that the GFRP met the design requirements of ITER.
NASA Technical Reports Server (NTRS)
Alberts, Thomas E.; Xia, Houchun; Chen, Yung
1992-01-01
The effectiveness of constrained viscoelastic layer damping treatment designs is evaluated separately as passive control measures for low frequency joint dominated modes and higher frequency boom flexure dominated modes using a NASTRAN finite element analysis. Passive damping augmentation is proposed which is based on a constrained viscoelastic layer damping treatment applied to the surface of the manipulators's flexible booms. It is pointed out that even the joint compliance dominated modes can be damped to some degree through appropriate design of the treatment.
Vereb, Marika; Liepe, Knut; Fischer, Manfred; Kaliska, Lucia; Noskovicova, Lucia; Balogova, Sona
2018-01-01
There is a clinical need for therapeutic alternative in patients with persisting painful arthritis of AC-joint and failure of previous treatments. However, no radiopharmaceutical is currently explicitly approved for radiosynoviorthesis of acromioclavicular joint. The aim of our study was to prospectively assess the efficacy and safety of radiosynoviorthesis of acromioclavicular joint using erbium-169 citrate. Radiosynoviorthesis of acromioclavicular joint was performed in 51 consecutive patients (18 males, 33 females) mean age 64.3 (range 43.8-82.6, median 63.6) years with clinically confirmed arthritis of 85 acromioclavicular joints. The efficacy of RSO was reported by patients according to 10-step visual analogue scale of pain (VAS) (0 = no pain, 10 = most severe pain) at 6 months after radiosynoviorthesis and by ranking the global therapeutic effect of RSO in 4 categories (1 = the best effect, 4 = no change). To assess the variation of blood perfusion in treated joints, the efficacy of RSO was also evaluated by variation of target (acromioclavicular joint)/non-target (soft tissue) uptake ratio (T/NTR) of metylendiphosphonate (99mTc) measured as number of counts over region of interest on blood pool phase of two-phase bone scintigraphy performed before and 6 months after RSO. Radiosynoviorthesis was followed by significant decrease in VAS, mean - 3.1 (-47%). Excellent, good, moderate and bad response was observed in 57 (67%), 25 (29%), 1 (1%) and in 2 (2%) of acromioclavicular joints respectively. A significant correlation between decrease of T/NTR and variation of VAS in % (ρ = 0.532, p < 0.0001) and between T/NTR and subjective evaluation of therapeutic effect in scale 1-4 (ρ = 0.388, p = 0.0002) was observed. However, it was not possible to identify the cut-off value of relative decrease in T/NTR showing sufficient sensitivity and specificity to detect the therapeutic response. Results of this prospective study permit to conclude a good efficacy and safety of radiosynoviorthesis using erbium-169 citrate in a series of patients with arthritis of acromioclavicular joint in whom previous line(s) of treatment did not lead to satisfactory pain relief.
Teacher Perspectives of the Use of Student Performance Data in Teacher Evaluations
ERIC Educational Resources Information Center
Hopkins, Paul Thomas
2013-01-01
The purpose of this study was to determine how K-12 public school teachers perceive the use of student performance data in teacher evaluations. The proprietary, utility, feasibility, and accuracy standards created by the Joint Committee on Standards for Education Evaluation (JCSEE) served as a framework for the study. An online survey was deployed…
ERIC Educational Resources Information Center
Achieve, Inc., 2014
2014-01-01
In joint partnership, Achieve, The Council of Chief State School Officers, and Student Achievement Partners have developed a Toolkit for Evaluating the Alignment of Instructional and Assessment Materials to the Common Core State Standards. The Toolkit is a set of interrelated, freely available instruments for evaluating alignment to the CCSS; each…
The Origin and Development of the African Evaluation Guidelines
ERIC Educational Resources Information Center
Rouge, Jean-Charles
2004-01-01
In May 1990, the first evaluation seminar in Africa took place in Cote d'Ivoire. It was the first in a series of regional seminars on evaluation planned by the Development Assistance Committee (DAC) of the Organization for Economic Cooperation and Development (OECD). The seminar was jointly presented by the DAC and African Development Bank (ADB).…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chow, J; Owrangi, A; Jiang, R
2014-06-01
Purpose: This study investigated the performance of the anisotropic analytical algorithm (AAA) in dose calculation in radiotherapy concerning a small finger joint. Monte Carlo simulation (EGSnrc code) was used in this dosimetric evaluation. Methods: Heterogeneous finger joint phantom containing a vertical water layer (bone joint or cartilage) sandwiched by two bones with dimension 2 × 2 × 2 cm{sup 3} was irradiated by the 6 MV photon beams (field size = 4 × 4 cm{sup 2}). The central beam axis was along the length of the bone joint and the isocenter was set to the center of the joint. Themore » joint width and beam angle were varied from 0.5–2 mm and 0°–15°, respectively. Depth doses were calculated using the AAA and DOSXYZnrc. For dosimetric comparison and normalization, dose calculations were repeated in water phantom using the same beam geometry. Results: Our AAA and Monte Carlo results showed that the AAA underestimated the joint doses by 10%–20%, and could not predict joint dose variation with changes of joint width and beam angle. The calculated bone dose enhancement for the AAA was lower than Monte Carlo and the depth of maximum dose for the phantom was smaller than that for the water phantom. From Monte Carlo results, there was a decrease of joint dose as its width increased. This reflected the smaller the joint width, the more the bone scatter contributed to the depth dose. Moreover, the joint dose was found slightly decreased with an increase of beam angle. Conclusion: The AAA could not handle variations of joint dose well with changes of joint width and beam angle based on our finger joint phantom. Monte Carlo results showed that the joint dose decreased with increase of joint width and beam angle. This dosimetry comparison should be useful to radiation staff in radiotherapy related to small bone joint.« less
Reliability of joint count assessment in rheumatoid arthritis: a systematic literature review.
Cheung, Peter P; Gossec, Laure; Mak, Anselm; March, Lyn
2014-06-01
Joint counts are central to the assessment of rheumatoid arthritis (RA) but reliability is an issue. To evaluate the reliability and agreement of joint counts (intra-observer and inter-observer) by health care professionals (physicians, nurses, and metrologists) and patients in RA, and the impact of training and standardization on joint count reliability through a systematic literature review. Articles reporting joint count reliability or agreement in RA in PubMed, EMBase, and the Cochrane library between 1960 and 2012 were selected. Data were extracted regarding tender joint counts (TJCs) and swollen joint counts (SJCs) derived by physicians, metrologists, or patients for intra-observer and inter-observer reliability. In addition, methods and effects of training or standardization were extracted. Statistics expressing reliability such as intraclass correlation coefficients (ICCs) were extracted. Data analysis was primarily descriptive due to high heterogeneity. Twenty-eight studies on health care professionals (HCP) and 20 studies on patients were included. Intra-observer reliability for TJCs and SJCs was good for HCPs and patients (range of ICC: 0.49-0.98). Inter-observer reliability between HCPs for TJCs was higher than for SJCs (range of ICC: 0.64-0.88 vs. 0.29-0.98). Patient inter-observer reliability with HCPs as comparators was better for TJCs (range of ICC: 0.31-0.91) compared to SJCs (0.16-0.64). Nine studies (7 with HCPs and 2 with patients) evaluated consensus or training, with improvement in reliability of TJCs but conflicting evidence for SJCs. Intra- and inter-observer reliability was high for TJCs for HCPs and patients: among all groups, reliability was better for TJCs than SJCs. Inter-observer reliability of SJCs was poorer for patients than HCPs. Data were inconclusive regarding the potential for training to improve SJC reliability. Overall, the results support further evaluation for patient-reported joint counts as an outcome measure. © 2013 Published by Elsevier Inc.
Evaluating the Upset Protrusion Joining (UPJ) Method to Join Magnesium Castings to Dissimilar Metals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Logan, Stephen
2016-02-24
This presentation discusses advantages and best practices for incorporating magnesium in automotive component applications to achieve substantial mass reduction, as well as some of the key challenges with respect to joining, coating, and galvanic corrosion, before providing an introduction and status update of the U.S. Department of Energy and Department of Defense jointly sponsored Upset Protrusion Joining (UPJ) process development and evaluation project. This update includes sharing performance results of a benchmark evaluation of the self-pierce riveting (SPR) process for joining dissimilar magnesium (Mg) to aluminum (Al) materials in four unique coating configurations before introducing the UPJ concept and comparingmore » performance results of the joints made with the UPJ process to those made with the SPR process. Key results presented include: The benchmark SPR process can produce good joints in the MgAM60B-Al 6013 joint configuration with minimal cracking in the Mg coupons if the rivet is inserted from the Mg side into the Al side; Numerous bare Mg to bare Al joints made with the SPR process separated after only 6-wks of accelerated corrosion testing due to fracture of the rivet as a result of hydrogen embrittlement; For the same joint configurations, UPJ demonstrated substantially higher pre-corrosion joint strengths and post-corrosion joint strengths, primarily because of the larger diameter protrusion compared to smaller SPR rivet diameter and reduced degradation due to accelerated corrosion exposure; As with the SPR process, numerous bare Mg to bare Al joints made with the UPJ process also separated after 6-wks of accelerated corrosion testing, but unlike the SPR experience, the UPJ joints experienced degradation of the boss and head because of galvanic corrosion of the Mg casting, not hydrogen embrittlement of the steel rivet; In the configuration where both the Mg and Al were pretreated with Alodine 5200 prior to joining and the complete assembly was powder-coated afterwards, the UPJ process showed substantial improvement in corrosion performance compared to SPR where many SPR joints had separated after only 6-wks of exposure, but none of the UPJ joints had separated even after 8-wis; and In the cases where the Al panel was coated prior to joining to the pretreated Mg coupons, neither the SPR or UPJ joints showed any joint separation or substantial joint performance degradation even after 12-wks of accelerated corrosion exposure.« less
DEMONSTRATION AND EVALUATION OF INNOVATIVE REMEDIATION TECHNOLOGIES THROUGH THE EPA SITE PROGRAM
The Superfund Innovative Technology Evaluation (SITE) Program has successfuly promoted the development, commercialization and implementation of innovative hazardous waste treatment technologies for 18 years. SITE offers a mechanism for conducting joint technology demonstration an...
SUPERFUND INNOVATIVE TECHNOLOGY EVALUATION PROGRAM ANNUAL REPORT TO CONGRESS FY 1996
The Superfund Innovative Technology Evaluation (SITE) Program has been successfully promoting the development, commercialization and implementation of innovative hazardous waste treatment technologies for more than 10 years. SITE offers a mechanism for conducting joint technology...
SUPERFUND INNOVTIVE TECHNOLOGY EVALUATION PROGRAM ANNUAL REPORT TO CONGRESS FY 1997
The Superfund Innovative Technology Evaluation (SITE) Program has successfully promoted the development, commercialization and implementation of innovative hazardous waste treatment technologies for more than 12 years. SITE offers a mechanism for conducting joint technology demon...
THE SUPERFUND INNOVATIVE TECHNOLOGY EVALUATION PROGRAM ANNUAL REPORT TO CONGRESS FY1999
The Superfund Innovative Technology Evaluation (SITE) Program has successfully promoted the development, commercialization and implementation of innovative hazardous waste treatment technologies for more than 14 years. SITE offers a mechanism for conducting joint technology demon...
2010-01-01
Background Tasks chosen to evaluate motor performance should reflect the movement deficits characteristic of the target population and present an appropriate challenge for the patients who would be evaluated. A reaching task that evaluates impairment characteristics of people with shoulder impingement syndrome (SIS) was developed to evaluate the motor performance of this population. The objectives of this study were to characterize the reproducibility of this reaching task in people with and without SIS and to evaluate the impact of the number of trials on reproducibility. Methods Thirty subjects with SIS and twenty healthy subjects participated in the first measurement session to evaluate intrasession reliability. Ten healthy subjects were retested within 2 to 7 days to assess intersession reliability. At each measurement session, upper extremity kinematic patterns were evaluated during a reaching task. Ten trials were recorded. Thereafter, the upper extremity position at the end of reaching and total joint excursion that occurred during reaching were calculated. Intraclass correlation coefficient (ICC) and minimal detectable change (MDC) were used to estimate intra and intersession reliability. Results Intrasession reliability for total joint excursion was good to very good when based on the first two trials (0.77
ERIC Educational Resources Information Center
Elison, Jed T.; Wolff, Jason J.; Heimer, Debra C.; Paterson, Sarah J.; Gu, Hongbin; Hazlett, Heather C.; Styner, Martin; Gerig, Guido; Piven, Joseph
2013-01-01
Elucidating the neural basis of joint attention in infancy promises to yield important insights into the development of language and social cognition, and directly informs developmental models of autism. We describe a new method for evaluating responding to joint attention performance in infancy that highlights the 9- to 10-month period as a time…
Pathological Knee Joint Motion Analysis By High Speed Cinephotography
NASA Astrophysics Data System (ADS)
Baumann, Jurg U.
1985-02-01
The use of cinephotography for evaluation of disturbed knee joint function was compared in three groups of patients. While a sampling rate of 50 images per second was adequate for patients with neuromuscular disorders, a higher frequency of around 300 i.p.s. is necessary in osteoarthritis and ligamentous knee joint injuries, but the task of digitizing is prohibitive unless automated.
2010-12-01
59 a. The Joint Uniform Lessons Learned System (JULLS) .........59 b. Acquisition Community Connection (ACC) ..........................59 c...Report ACC Acquisition Community Connection ADDIE Analyze, Design, Develop, Implement, Evaluate AFFARS Air Force Federal Acquisition Regulation...Operations J4 Logistics J5 Plans J6 Communications J8 Programming and Comptroller J&A Justification and Approval JARB Joint Acquisition
A systematic evaluation of prevalence and diagnostic accuracy of sacroiliac joint interventions.
Simopoulos, Thomas T; Manchikanti, Laxmaiah; Singh, Vijay; Gupta, Sanjeeva; Hameed, Haroon; Diwan, Sudhir; Cohen, Steven P
2012-01-01
The contributions of the sacroiliac joint to low back and lower extremity pain have been a subject of considerable debate and research. It is generally accepted that 10% to 25% of patients with persistent mechanical low back pain below L5 have pain secondary to sacroiliac joint pathology. However, no single historical, physical exam, or radiological feature can definitively establish a diagnosis of sacroiliac joint pain. Based on present knowledge, a proper diagnosis can only be made using controlled diagnostic blocks. The diagnosis and treatment of sacroiliac joint pain continue to be characterized by wide variability and a paucity of the literature. To evaluate the accuracy of diagnostic sacroiliac joint interventions. A systematic review of diagnostic sacroiliac joint interventions. Methodological quality assessment of included studies was performed using Quality Appraisal of Reliability Studies (QAREL). Only diagnostic accuracy studies meeting at least 50% of the designated inclusion criteria were utilized for analysis. Studies scoring less than 50% are presented descriptively and analyzed critically. The level of evidence was classified as good, fair, or poor based on the quality of evidence developed by the United States Preventive Services Task Force (USPSTF). Data sources included relevant literature identified through searches of PubMed and EMBASE from 1966 to December 2011, and manual searches of the bibliographies of known primary and review articles. In this evaluation we utilized controlled local anesthetic blocks using at least 50% pain relief as the reference standard. The evidence is good for the diagnosis of sacroiliac joint pain utilizing controlled comparative local anesthetic blocks. The prevalence of sacroiliac joint pain is estimated to range between 10% and 62% based on the setting; however, the majority of analyzed studies suggest a point prevalence of around 25%, with a false-positive rate for uncontrolled blocks of approximately 20%. The evidence for provocative testing to diagnose sacroiliac joint pain was fair. The evidence for the diagnostic accuracy of imaging is limited. The limitations of this systematic review include a paucity of literature, variations in technique, and variable criterion standards for the diagnosis of sacroiliac joint pain. Based on this systematic review, the evidence for the diagnostic accuracy of sacroiliac joint injections is good, the evidence for provocation maneuvers is fair, and evidence for imaging is limited.
Effectiveness study of UNL's pneumatic crack/joint preparation device.
DOT National Transportation Integrated Search
2014-03-01
The aim of this project was to evaluate the effectiveness of the crack cleaning device (CCD) for improving the current crack/joint preparation practices and for possible adoption as a standard in Nebraska Department of Roads (NDOR). Through the colla...
Xu, Hang; Merryweather, Andrew; Bloswick, Donald; Mao, Qi; Wang, Tong
2015-01-01
Marker placement can be a significant source of error in biomechanical studies of human movement. The toe marker placement error is amplified by footwear since the toe marker placement on the shoe only relies on an approximation of underlying anatomical landmarks. Three total knee replacement subjects were recruited and three self-speed gait trials per subject were collected. The height variation between toe and heel markers of four types of footwear was evaluated from the results of joint kinematics and muscle forces using OpenSim. The reference condition was considered as the same vertical height of toe and heel markers. The results showed that the residual variances for joint kinematics had an approximately linear relationship with toe marker placement error for lower limb joints. Ankle dorsiflexion/plantarflexion is most sensitive to toe marker placement error. The influence of toe marker placement error is generally larger for hip flexion/extension and rotation than hip abduction/adduction and knee flexion/extension. The muscle forces responded to the residual variance of joint kinematics to various degrees based on the muscle function for specific joint kinematics. This study demonstrates the importance of evaluating marker error for joint kinematics and muscle forces when explaining relative clinical gait analysis and treatment intervention.
Neuromuscular prehabilitation to prevent osteoarthritis after a traumatic joint injury.
Tenforde, Adam S; Shull, Pete B; Fredericson, Michael
2012-05-01
Post-traumatic osteoarthritis (PTOA) is a process resulting from direct forces applied to a joint that cause injury and degenerative changes. An estimated 12% of all symptomatic osteoarthritis (OA) of the hip, knee, and ankle can be attributed to a post-traumatic cause. Neuromuscular prehabilitation is the process of improving neuromuscular function to prevent development of PTOA after an initial traumatic joint injury. Prehabilitation strategies include restoration of normative movement patterns that have been altered as the result of traumatic injury, along with neuromuscular exercises and gait retraining to prevent the development of OA after an injury occurs. A review of the current literature shows that no studies have been performed to evaluate methods of neuromuscular prehabilitation to prevent PTOA after a joint injury. Instead, current research has focused on management strategies after knee injuries, the value of exercise in the management of OA, and neuromuscular exercises after total knee arthroplasty. Recent work in gait retraining that alters knee joint loading holds promise for preventing the development of PTOA after joint trauma. Future research should evaluate methods of neuromuscular prehabilitation strategies in relationship to the outcome of PTOA after joint injury. Copyright © 2012 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Murphy, M. K.; Arzi, B.; Vapniarsky-Arzi, N.; Athanasiou, K. A.
2013-01-01
Summary The articulation of the temporomandibular joint (TMJ) is composed of the temporal bone dorsally, the mandibular condyle ventrally and a fibrous articular disc. The TMJ disc plays an essential role in distributing load between the two articular surfaces. Degeneration of the disc in the presence of joint pathology has been shown in man; however, TMJ pathology has not been documented previously in tigers (Panthera tigris). The mandibular condyle and TMJ disc of a Bengal tiger (P. tigris tigris) and a Siberian tiger (P. tigris altaica) were evaluated grossly and the TMJ disc was characterized biochemically and mechanically. Characterization of the TMJ disc verified region- and direction-dependent biochemical and mechanical properties, reflective of the functional demands on the joint. Degenerative joint disease was observed in both cases and this was more severe in the Siberian tiger. Simultaneous evaluation of joint pathology, biochemical composition and mechanical properties of the TMJ disc revealed a loss in functional properties (tensile anisotropy) of the disc as joint pathology advanced from moderate to severe. TMJ degeneration may compromise the ability of the animal to eat and thrive and may be a factor contributing to the endangered status of these species. PMID:23809909
Brachygnathia superior and degenerative joint disease: a new lethal syndrome in Angus calves.
Jayo, M; Leipold, H W; Dennis, S M; Eldridge, F E
1987-03-01
Brachygnathia superior and generalized diarthrodial degenerative joint disease were seen in 17 related, purebred Angus calves ranging in age from 2 days to 4 months. Craniometrical studies revealed decreased maxillary and palatine bone lengths and increased cranial, skull, and facial indices. Radiological evaluation of major appendicular joints demonstrated lipping of the joint margins with osteophyte formation, sclerosis of subchondral bone, and narrowing of joint spaces. Synovial fluid evaluation indicated joint degeneration but no etiologic agent. Rheumatoid factor analysis of plasma was negative. Grossly, all major appendicular joints were defective including the atlanto-occipital articulation. Lesions ranged from loss of surface luster to erosions and deep ulcers with eburnation of the subchondral bone and secondary proliferative synovitis. Histological changes were degeneration of the articular cartilage matrix, chondrocyte necrosis, flaking and fibrillation, chondrone formation, erosions and ulcers of the articular cartilage with subchondral bone sclerosis, vascular invasion with fibrosis, and chronic, nonsuppurative, proliferative synovitis. Growth plates had defective chondrocyte proliferation and hypertrophy with aberrant ossification of calcified cartilaginous matrix. Histochemical analysis of cartilage and bone failed to incriminate which component was defective, glycosaminoglycan or collagen, but indicated different distribution or absence of one or the other. Genealogic studies revealed a genetic basis for the new defect.
Stress analysis of bolted joints under centrifugal force
NASA Astrophysics Data System (ADS)
Imura, Makoto; Iizuka, Motonobu; Nakae, Shigeki; Mori, Takeshi; Koyama, Takayuki
2014-06-01
Our objective is to develop a long-life rotary machine for synchronous generators and motors. To do this, it is necessary to design a high-strength bolted joint, which is responsible for fixing a salient pole on a rotor shaft. While the rotary machine is in operation, not only centrifugal force but also moment are loaded on a bolted joint, because a point of load is eccentric to a centre of a bolt. We tried to apply the theory proposed in VDI2230-Blatt1 to evaluate the bolted joint under eccentric force, estimate limited centrifugal force, which is the cause of partial separation between the pole and the rotor shaft, and then evaluate additional tension of a bolt after the partial separation has occurred. We analyzed the bolted joint by FEM, and defined load introduction factor in that case. Additionally, we investigated the effect of the variation of bolt preload on the partial separation. We did a full scale experiment with a prototype rotor to reveal the variation of bolt preload against tightening torque. After that, we verified limited centrifugal force and the strength of the bolted joint by the VDI2230-Blatt1 theory and FEM considering the variation of bolt preload. Finally, we could design a high-strength bolted joint verified by the theoretical study and FEM analysis.
Murphy, M K; Arzi, B; Vapniarsky-Arzi, N; Athanasiou, K A
2013-11-01
The articulation of the temporomandibular joint (TMJ) is composed of the temporal bone dorsally, the mandibular condyle ventrally and a fibrous articular disc. The TMJ disc plays an essential role in distributing load between the two articular surfaces. Degeneration of the disc in the presence of joint pathology has been shown in man; however, TMJ pathology has not been documented previously in tigers (Panthera tigris). The mandibular condyle and TMJ disc of a Bengal tiger (P. tigris tigris) and a Siberian tiger (P. tigris altaica) were evaluated grossly and the TMJ disc was characterized biochemically and mechanically. Characterization of the TMJ disc verified region- and direction-dependent biochemical and mechanical properties, reflective of the functional demands on the joint. Degenerative joint disease was observed in both cases and this was more severe in the Siberian tiger. Simultaneous evaluation of joint pathology, biochemical composition and mechanical properties of the TMJ disc revealed a loss in functional properties (tensile anisotropy) of the disc as joint pathology advanced from moderate to severe. TMJ degeneration may compromise the ability of the animal to eat and thrive and may be a factor contributing to the endangered status of these species. Copyright © 2013 Elsevier Ltd. All rights reserved.
Analysis of Bonded Joints Between the Facesheet and Flange of Corrugated Composite Panels
NASA Technical Reports Server (NTRS)
Yarrington, Phillip W.; Collier, Craig S.; Bednarcyk, Brett A.
2008-01-01
This paper outlines a method for the stress analysis of bonded composite corrugated panel facesheet to flange joints. The method relies on the existing HyperSizer Joints software, which analyzes the bonded joint, along with a beam analogy model that provides the necessary boundary loading conditions to the joint analysis. The method is capable of predicting the full multiaxial stress and strain fields within the flange to facesheet joint and thus can determine ply-level margins and evaluate delamination. Results comparing the method to NASTRAN finite element model stress fields are provided illustrating the accuracy of the method.
Development of a Portable Knee Rehabilitation Device That Uses Mechanical Loading.
Fitzwater, Daric; Dodge, Todd; Chien, Stanley; Yokota, Hiroki; Anwar, Sohel
2013-12-01
Joint loading is a recently developed mechanical modality, which potentially provides a therapeutic regimen to activate bone formation and prevent degradation of joint tissues. To our knowledge, however, few joint loading devices are available for clinical or point-of-care applications. Using a voice-coil actuator, we developed an electromechanical loading system appropriate for human studies and preclinical trials that should prove both safe and effective. Two specific tasks for this loading system were development of loading conditions (magnitude and frequency) suitable for humans, and provision of a convenient and portable joint loading apparatus. Desktop devices have been previously designed to evaluate the effects of various loading conditions using small and large animals. However, a portable knee loading device is more desirable from a usability point of view. In this paper, we present such a device that is designed to be portable, providing a compact, user-friendly loader. The portable device was employed to evaluate its capabilities using a human knee model. The portable device was characterized for force-pulse width modulation duty cycle and loading frequency properties. The results demonstrate that the device is capable of producing the necessary magnitude of forces at appropriate frequencies to promote the stimulation of bone growth and which can be used in clinical studies for further evaluations.
Struik, T; Jaspers, J E N; Besselink, N J; van Roermund, P M; Plomp, S; Rudert, M J; Lafeber, F P J G; Mastbergen, S C
2017-11-01
Knee osteoarthritis is a highly prevalent degenerative joint disorder characterized by joint tissue damage and pain. Knee joint distraction has been introduced as a joint preserving surgical procedure to postpone knee arthroplasty. An often used standard externally fixation device for distraction poses a burden to patients due to the absence of joint flexion during the 6weeks treatment. Therefore, a personalized articulating distraction device was developed. The aim of this study was to test technical feasibility of this device. Based on an often applied rigid device, using equal bone pin positions and connectors, a hinge mechanism was developed consisting of a cam-following system for reproducing the complex joint-specific knee kinematics. In support, a device was developed for capturing the joint-specific sagittal plane articulation. The obtained kinematic data were translated into joint-specific cam shapes that were installed bilaterally in the hinge mechanism of the distraction device, as such providing personalized knee motion. Distraction of 5mm was performed within a range of motion of 30deg. joint flexion. Pre-clinical evaluation of the working principle was performed on human cadaveric legs and system stiffness characteristics were biomechanically evaluated. The desired range of motion was obtained and distraction was maintained under physiologically representative loading. Moreover, the joint-specific approach demonstrated tolerance of deviations from anatomical and alignment origin during initial placement of the developed distraction device. Articulation during knee distraction is considered technically feasible and has potential to decrease burden and improve acceptance of distraction therapy. Testing of clinical feasibility is warranted. Copyright © 2017 Elsevier Ltd. All rights reserved.
Joint Laxity in Preschool Children Born Preterm.
Romeo, Domenico M; Velli, Chiara; Lucibello, Simona; Ferrantini, Gloria; Leo, Giuseppina; Brogna, Claudia; Cota, Francesco; Ricci, Daniela; Gallini, Francesca; Romagnoli, Costantino; Vento, Giovanni; Mercuri, Eugenio
2018-06-01
To evaluate the prevalence of joint laxity in children born preterm assessed in the first 2 years, the relationship between joint laxity and motor performance at preschool age, and possible changes over time in a subgroup of children followed longitudinally. The revised scale of Beighton Score was used to evaluate joint laxity in a population of 132 preschool children born preterm between 24 and 32 weeks of gestational age. All were assessed for joint laxity between 12 and 24 months of age. Children also performed the Movement Assessment Battery for Children-Second Edition between the age of 3 years and 6 months and 4 years; the age at onset of independent walking also was recorded. The total Beighton Score ranged between 0 and 8. Twenty percent of the cohort showed joint laxity. No differences related to sex or gestational age were observed. Children born preterm with joint laxity achieved later independent walking and achieved lower scores on Movement Assessment Battery for Children-Second Edition than those without joint laxity. In 76 children born preterm, an assessment for joint laxity was repeated once between 25 and 36 months and again after >36 months. No statistically significant difference was observed between the 3 assessments. The Beighton Score can be used to assess generalized joint laxity in children born preterm. As the presence of joint laxity influenced motor competences, the possibility to early identify these infants in the first 2 years is of interest to benefit from early intervention and potentially improve gross motor skills and coordination. Copyright © 2018 Elsevier Inc. All rights reserved.
Axelsen, Mette Bjørndal; Eshed, Iris; Duer-Jensen, Anne; Møller, Jakob M; Pedersen, Susanne Juhl; Østergaard, Mikkel
2014-05-01
The aim of this study was to investigate the ability of whole-body MRI (WBMRI) to visualize inflammation [synovitis, bone marrow oedema (BME) and enthesitis] and structural damage in patients with RA. The 3T WBMR images were acquired in a head-to-toe scan in 20 patients with RA and at least one swollen or tender joint. Short Tau Inversion Recovery and pre- and post-contrast T1-weighted images were evaluated for readability and the presence/absence of inflammation (synovitis, BME and enthesitis) and structural damage (erosions and fat infiltrations) in 76 peripheral joints, 30 entheseal sites and in the spine. The readability was >70% for all individual joints, except for the most peripheral joints of the hands and feet. Synovitis was most frequent in the wrist, first tarsometatarsal, first CMC joints and glenohumeral joints (67-61%); BME in the wrist, CMC, acromioclavicular and glenohumeral joints (45-35%) and erosions in the wrist, MTP and CMC joints (19-16%). Enthesitis at ≥ 1 site was registered in 16 patients. BME was frequently seen in the cervical (20%) but not the thoracic and lumbar spine, while fat infiltrations and erosions were rare. The intrareader agreement was high (85-100%) for all pathologies. The agreement between WBMRI and clinical findings was low. Peripheral and axial inflammation and structural damage at joints and entheses was frequently identified by WBMRI, and more frequently than by clinical examination. WBMRI is a promising tool for evaluation of the total inflammatory load of inflammation (an MRI joint count) and structural damage in RA patients.
NASA Technical Reports Server (NTRS)
Koumal, D. E.
1979-01-01
The design and evaluation of built-up attachments and bonded joint concepts for use at elevated temperatures is documented. Joint concept screening, verification of GR/PI material, fabrication of design allowables panels, definition of test matrices, and analysis of bonded and bolted joints are among the tasks completed. The results provide data for the design and fabrication of lightly loaded components for advanced space transportation systems and high speed aircraft.
2007-01-01
results could be compromised. While service development efforts tied to seabasing are approaching milestones for investment decisions , it is...estimates for joint seabasing options are developed and made transparent to DOD and Congress, decision makers will not be able to evaluate the cost...Integrate Service Initiatives 10 DOD Has Not Developed a Joint Experimentation Campaign Plan to Inform Decisions About Joint Seabasing 16 Timeframe for
NASA Astrophysics Data System (ADS)
Mehrishal, Seyedahmad; Sharifzadeh, Mostafa; Shahriar, Korosh; Song, Jae-Jon
2017-04-01
In relation to the shearing of rock joints, the precise and continuous evaluation of asperity interlocking, dilation, and basic friction properties has been the most important task in the modeling of shear strength. In this paper, in order to investigate these controlling factors, two types of limestone joint samples were prepared and CNL direct shear tests were performed on these joints under various shear conditions. One set of samples were travertine and another were onyx marble with slickensided surfaces, surfaces ground to #80, and rough surfaces were tested. Direct shear experiments conducted on slickensided and ground surfaces of limestone indicated that by increasing the applied normal stress, under different shearing rates, the basic friction coefficient decreased. Moreover, in the shear tests under constant normal stress and shearing rate, the basic friction coefficient remained constant for the different contact sizes. The second series of direct shear experiments in this research was conducted on tension joint samples to evaluate the effect of surface roughness on the shear behavior of the rough joints. This paper deals with the dilation and roughness interlocking using a method that characterizes the surface roughness of the joint based on a fundamental combined surface roughness concept. The application of stress-dependent basic friction and quantitative roughness parameters in the continuous modeling of the shear behavior of rock joints is an important aspect of this research.
Knee joint transplantation combined with surgical angiogenesis in rabbits – a new experimental model
Kremer, Thomas; Giusti, Guilherme; Friedrich, Patricia F.; Willems, Wouter; Bishop, Allen T.; Giessler, Goetz A.
2012-01-01
Summary Purpose We have previously described a means to maintain bone allotransplant viability, without long-term immune modulation, replacing allogenic bone vasculature with autogenous vessels. A rabbit model for whole knee joint transplantation was developed and tested using the same methodology, initially as an autotransplant. Materials/Methods Eight New Zealand White rabbit knee joints were elevated on a popliteal vessel pedicle to evaluate limb viability in a non-survival study. Ten additional joints were elevated and replaced orthotopically in a fashion identical to allotransplantation, obviating only microsurgical repairs and immunosuppression. A superficial inferior epigastric facial (SIEF) flap and a saphenous arteriovenous (AV) bundle were introduced into the femur and tibia respectively, generating a neoangiogenic bone circulation. In allogenic transplantation, this step maintains viability after cessation of immunosuppression. Sixteen weeks later, x-rays, microangiography, histology, histomorphometry and biomechanical analysis were performed. Results Limb viability was preserved in the initial 8 animals. Both soft tissue and bone healing occurred in 10 orthotopic transplants. Surgical angiogenesis from the SIEF flap and AV bundle was always present. Bone and joint viability was maintained, with demonstrable new bone formation. Bone strength was less than the opposite side. Arthrosis and joint contractures were frequent. Conclusion We have developed a rabbit knee joint model and evaluation methods suitable for subsequent studies of whole joint allotransplantation. PMID:22113889
2016-01-01
This report represents the conclusions of a Joint FAO/WHO Expert Committee convened to evaluate the safety of residues of certain veterinary drugs in food and to recommend maximum levels for such residues in food. The first part of the report considers general principles regarding the evaluation of residues of veterinary drugs within the terms of reference of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), including MRLs for generic fish species, acute reference doses (ARfDs) for veterinary drugs, an approach for dietary exposure assessment of compounds used for multiple purposes (i.e veterinary drugs and pesticides), dietary exposure assessment for less-than-lifetime exposure, and the assessment of short-term (90-day and 12-month) studies in dogs. Summaries follow of the Committee's evaluations of toxicological and residue data on a variety of veterinary drugs: two insecticides (diflubenzuron and teflubenzuron), an antiparasitic agent (ivermectin), an ectoparasiticide (sisapronil) and a β2-adrenoceptor agonist (zilpaterol hydrochloride). In addition, the Committee considered issues raised in concern forms from the Codex Committee on Residues of Veterinary Drugs in Foods on lasalocid sodium, an antiparasitic agent. Annexed to the report is a summary of the Committee's recommendations on these drugs, including acceptable daily intakes (ADIs), ARfDs and proposed MRLs.
Simpson, Brad G; Simon, Corey B
2014-05-01
A 40-year old female presented to physical therapy with a one-year history of insidious right anteromedial and anterolateral knee pain. Additionally, the patient had a history of multiple lateral ankle sprains bilaterally, the last sprain occurring on the right ankle 1 year prior to the onset of knee pain. The patient was evaluated and given a physical therapy diagnosis of patellofemoral pain syndrome (PFPS), with associated talocrural and tibiofemoral joint hypomobility limiting ankle dorsiflexion and knee extension, respectively. Treatment included a high-velocity low amplitude thrust manipulation to the talocrural joint, which helped restore normal ankle dorsiflexion range of motion. The patient also received tibiofemoral joint non-thrust manual therapy to regain normal knee extension mobility prior to implementing further functional progression exercises to her home program (HEP). This case report highlights the importance of a detailed evaluation of knee and ankle joint mobility in patients presenting with anterior knee pain. Further, manual physical therapy to the lower extremity was found to be successful in restoring normal movement patterns and pain-free function in a patient with chronic anterior knee pain.
Interprofessional approach for teaching functional knee joint anatomy.
Meyer, Jakob J; Obmann, Markus M; Gießler, Marianne; Schuldis, Dominik; Brückner, Ann-Kathrin; Strohm, Peter C; Sandeck, Florian; Spittau, Björn
2017-03-01
Profound knowledge in functional and clinical anatomy is a prerequisite for efficient diagnosis in medical practice. However, anatomy teaching does not always consider functional and clinical aspects. Here we introduce a new interprofessional approach to effectively teach the anatomy of the knee joint. The presented teaching approach involves anatomists, orthopaedists and physical therapists to teach anatomy of the knee joint in small groups under functional and clinical aspects. The knee joint courses were implemented during early stages of the medical curriculum and medical students were grouped with students of physical therapy to sensitize students to the importance of interprofessional work. Evaluation results clearly demonstrate that medical students and physical therapy students appreciated this teaching approach. First evaluations of following curricular anatomy exams suggest a benefit of course participants in knee-related multiple choice questions. Together, the interprofessional approach presented here proves to be a suitable approach to teach functional and clinical anatomy of the knee joint and further trains interprofessional work between prospective physicians and physical therapists as a basis for successful healthcare management. Copyright © 2016 The Authors. Published by Elsevier GmbH.. All rights reserved.
Nondestructive Evaluation of Friction Stir-Welded Aluminum Alloy to Coated Steel Sheet Lap Joint
NASA Astrophysics Data System (ADS)
Das, H.; Kumar, A.; Rajkumar, K. V.; Saravanan, T.; Jayakumar, T.; Pal, Tapan Kumar
2015-11-01
Dissimilar lap joints of aluminum sheet (AA 6061) of 2 mm thickness and zinc-coated steel sheet of 1 mm thickness were produced by friction stir welding with different combinations of rotational speed and travel speed. Ultrasonic C- and B-scanning, and radiography have been used in a complementary manner for detection of volumetric (cavity and flash) and planar (de bond) defects as the defects are in micron level. Advanced ultrasonic C-scanning did not provide any idea about the defects, whereas B-scanning cross-sectional image showed an exclusive overview of the micron-level defects. A digital x-ray radiography methodology is proposed for quality assessment of the dissimilar welds which provide three-fold increase in signal-to-noise ratio with improved defect detection sensitivity. The present study clearly shows that the weld tool rotational speed and travel speed have a decisive role on the quality of the joints obtained by the friction stir welding process. The suitability of the proposed NDE techniques to evaluate the joint integrity of dissimilar FSW joints is thus established.
Design and evaluation of a bolted joint for a discrete carbon-epoxy rod-reinforced hat section
NASA Technical Reports Server (NTRS)
Rousseau, Carl Q.; Baker, Donald J.
1996-01-01
The use of prefabricated pultruded carbon-epoxy rods has reduced the manufacturing complexity and costs of stiffened composite panels while increasing the damage tolerance of the panels. However, repairability of these highly efficient discrete stiffeners has been a concern. Design, analysis, and test results are presented in this paper for a bolted-joint repair for the pultruded rod concept that is capable of efficiently transferring axial loads in a hat-section stiffener on the upper skin segment of a heavily loaded aircraft wing component. A tension and a compression joint design were evaluated. The tension joint design achieved approximately 1.0% strain in the carbon-epoxy rod-reinforced hat-section and failed in a metal fitting at 166% of the design ultimate load. The compression joint design failed in the carbon-epoxy rod-reinforced hat-section test specimen area at approximately 0.7% strain and at 110% of the design ultimate load. This strain level of 0.7% in compression is similar to the failure strain observed in previously reported carbon-epoxy rod-reinforced hat-section column tests.
Ohio Route 50 joint sealant experiment.
DOT National Transportation Integrated Search
2002-03-01
This is the third and Final Report for a research project that entailed the construction and evaluation to date of a stretch of a four-lane highway near Athens, Ohio. The main purpose of this project has been to evaluate concrete pavement performance...
Real-Time Data Capture and Management Evaluation and Performance Measures : Evaluation Framework
DOT National Transportation Integrated Search
2011-09-01
Through connected vehicle research, the U.S. DOT Intelligent Transportation Systems Joint Program Office (ITS JPO) is leading an effort to assess the potential for systematic and dynamic data capture from vehicles, travelers and the transportation sy...
Avoiding Problems in Evaluation.
ERIC Educational Resources Information Center
Tallmadge, G. Kasten
1979-01-01
Discusses the need for awareness of real and potential problems in educational evaluation approaches, kinds of problems there are with true experimental designs and with quasi-experimental designs, and the criteria applied by the Joint Dissemination Review Panel to its review of educational programs. (MF)
21 CFR 26.38 - Other transition period activities.
Code of Federal Regulations, 2010 CFR
2010-04-01
... MUTUAL RECOGNITION OF PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN MEDICAL DEVICE PRODUCT EVALUATION REPORTS: UNITED STATES AND THE EUROPEAN... present in quality system and product evaluation reports. (b) The parties will jointly develop a...
Psychological Evaluation and Prescription Development Handbook.
ERIC Educational Resources Information Center
Vigo County School Corp., Terre Haute, IN.
Developed to aid children with learning difficulties, from mental retardation or brain injury to maladjustment or physical or environmental handicaps, the joint school services program provides psychological evaluation and prescription development. The handbook reviews theories of child development and surveys behavior modification and…
21 CFR 26.38 - Other transition period activities.
Code of Federal Regulations, 2011 CFR
2011-04-01
... MUTUAL RECOGNITION OF PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN MEDICAL DEVICE PRODUCT EVALUATION REPORTS: UNITED STATES AND THE EUROPEAN... present in quality system and product evaluation reports. (b) The parties will jointly develop a...
Sekir, U; Yildiz, Y; Hazneci, B; Ors, F; Saka, T; Aydin, T
2008-12-01
In contrast to the single evaluation methods used in the past, the combination of multiple tests allows one to obtain a global assessment of the ankle joint. The aim of this study was to determine the reliability of the different tests in a functional test battery. Twenty-four male recreational athletes with unilateral functional ankle instability (FAI) were recruited for this study. One component of the test battery included five different functional ability tests. These tests included a single limb hopping course, single-legged and triple-legged hop for distance, and six and cross six meter hop for time. The ankle joint position sense and one leg standing test were used for evaluation of proprioception and sensorimotor control. The isokinetic strengths of the ankle invertor and evertor muscles were evaluated at a velocity of 120 degrees /s. The reliability of the test battery was assessed by calculating the intraclass correlation coefficient (ICC). Each subject was tested two times, with an interval of 3-5 days between the test sessions. The ICCs for ankle functional and proprioceptive ability showed high reliability (ICCs ranging from 0.94 to 0.98). Additionally, isokinetic ankle joint inversion and eversion strength measurements represented good to high reliability (ICCs between 0.82 and 0.98). The functional test battery investigated in this study proved to be a reliable tool for the assessment of athletes with functional ankle instability. Therefore, clinicians may obtain reliable information from the functional test battery during the assessment of ankle joint performance in patients with functional ankle instability.
Martin, Heather A; Ciurzynski, Susan M
2015-11-01
Thousands of people die annually in hospitals because of poor communication and teamwork between health care team members. Standardized tools and strategies help increase the amount and quality of communication. Two structured communication methods include implementing huddles and the use of the situation, background, assessment, and recommendation (SBAR) communication framework. To improve communication among nurse practitioners and registered nurses within a pediatric emergency department, a performance-improvement project with the structured processes of a joint patient evaluation and huddle was implemented. Data were gathered from 32 nurses and 2 nurse practitioners using structured observation and pre- and post-implementation surveys. The following outcomes were measured: presence or absence of joint patient evaluation and SBAR-guided huddle, verbalization of treatment plan, communication, teamwork, and nurse satisfaction. Eighty-three percent of patient encounters included a joint evaluation. A huddle structured with SBAR was conducted 86% of the time. Registered nurses and nurse practitioners verbalized patients' treatment plans in 89% of cases and 97% of cases, respectively. Improved teamwork, communication, and nursing satisfaction scores were demonstrated among the nurse practitioners and registered nurses. This project showed the feasibility of a simple and inexpensive joint nurse practitioner-registered nurse patient evaluation followed by a structured huddle, which improved communication, teamwork, and nurse satisfaction scores. This performance-improvement project has the potential to enhance efficiency by reducing redundancy, as well as to improve patient safety through the use of structured communication techniques. Copyright © 2015 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.
Dutch Multidisciplinary Guideline for Invasive Treatment of Pain Syndromes of the Lumbosacral Spine.
Itz, Coen J; Willems, Paul C; Zeilstra, Dick J; Huygen, Frank J
2016-01-01
When conservative therapies such as pain medication or exercise therapy fail, invasive treatment may be indicated for patients with lumbosacral spinal pain. The Dutch Society of Anesthesiologists, in collaboration with the Dutch Orthopedic Association and the Dutch Neurosurgical Society, has taken the initiative to develop the guideline "Spinal low back pain," which describes the evidence regarding diagnostics and invasive treatment of the most common spinal low back pain syndromes, that is, facet joint pain, sacroiliac joint pain, coccygodynia, pain originating from the intervertebral disk, and failed back surgery syndrome. The aim of the guideline is to determine which invasive treatment intervention is preferred for each included pain syndrome when conservative treatment has failed. Diagnostic studies were evaluated using the EBRO criteria, and studies on therapies were evaluated with the Grading of Recommendations Assessment, Development and Evaluation system. For the evaluation of invasive treatment options, the guideline committee decided that the outcome measures of pain, function, and quality of life were most important. The definition, epidemiology, pathophysiological mechanism, diagnostics, and recommendations for invasive therapy for each of the spinal back pain syndromes are reported. The guideline committee concluded that the categorization of low back pain into merely specific or nonspecific gives insufficient insight into the low back pain problem and does not adequately reflect which therapy is effective for the underlying disorder of a pain syndrome. Based on the guideline "Spinal low back pain," facet joint pain, pain of the sacroiliac joint, and disk pain will be part of a planned nationwide cost-effectiveness study. © 2015 World Institute of Pain.
Improving air traffic control: Proving new tools or approving the joint human-machine system?
NASA Technical Reports Server (NTRS)
Gaillard, Irene; Leroux, Marcel
1994-01-01
From the description of a field problem (i.e., designing decision aids for air traffic controllers), this paper points out how a cognitive engineering approach provides the milestones for the evaluation of future joint human-machine systems.
Evaluation of the Long-Term Durability of Joints Cut Using Early Entry Saws on Rigid Pavements
DOT National Transportation Integrated Search
2011-01-01
Early-entry sawing is an attractive operation to expedite the construction of jointed concrete pavements; however, : there are some concerns that the early-entry sawing may compromise the pavements long-term performance. The Illinois : Department ...
Development of an Intelligent Stretching Device for Ankle Joints With Contracture/Spasticity
2001-10-25
percentage corresponded to background dorsi-flexion muscle contraction and 0% was the relaxed state. Next, tendon reflexes were evaluated...the representative cases, joint stiffness was reduced markedly after stretching across the range of muscle contraction (Fig. 5), including both
[Staple fixation for the treatment of hamate metacarpal joint injury].
Tang, Yang-Hua; Zeng, Lin-Ru; Huang, Zhong-Ming; Yue, Zhen-Shuang; Xin, Da-Wei; Xu, Can-Da
2014-03-01
To investigate the effcacy of the staple fixation for the treatment of hamate metacarpal joint injury. From May 2009 to November 2012,16 patients with hamate metacarpal joint injury were treated with staple fixation including 10 males and 6 females with an average age of 33.6 years old ranging from 21 to 57 years. Among them, 11 cases were on the fourth or fifth metacarpal base dislocation without fractures, 5 cases were the fourth or fifth metacarpal base dislocation with avulsion fractures of the back of hamatum. Regular X-ray review was used to observe the fracture healing, joint replacement and position of staple fixation. The function of carpometacarpal joint and metacarpophalangeal joint were evaluated according to ASIA (TAM) system evaluation method. All incision were healed well with no infection. All patients were followed up from 16 to 24 months with an average of (10.0 +/- 2.7) months. No dislocation recurred, the position of internal fixator was good,no broken nail and screw withdrawal were occurred. Five patients with avulsion fracture of the back of hamatum achieved bone healing. The function of carpometacarpal joint and metacarpophalangeal was excellent in 10 cases,good in 5 cases, moderate in 1 case. The application of the staple for the treatment of hamatometacarpal joint injury has the advantages of simple operation, small trauma, reliable fixation, early postoperative function exercise and other advantages, which is the ideal operation mode for hamatometacarpal joint injury.
ERIC Educational Resources Information Center
Colorado State General Assembly, Denver. Legislative Council.
The Interim Committee on Teacher Evaluation and Dismissal was established by (Colorado) Senate Joint Resolution 97-14 to study the state's teacher evaluation and dismissal laws and explore alternatives. The committee was directed to study the relationship between education reform and employment protections for teachers; the effectiveness of adding…
Ackland, David; Robinson, Dale; Lee, Peter Vee Sin; Dimitroulis, George
2018-05-11
Stock prosthetic temporomandibular joint replacements come in limited sizes, and do not always encompass the joint anatomy that presents clinically. The aims of this study were twofold. Firstly, to design a personalized prosthetic total joint replacement for the treatment of a patient's end-stage temporomandibular joint osteoarthritis, to implant the prosthesis into the patient, and assess clinical outcome 12-months post-operatively; and secondly, to evaluate the influence of changes in prosthetic condyle geometry on implant load response during mastication. A 48-year-old female patient with Grade-5 osteoarthritis to the left temporomandibular joint was recruited, and a prosthesis developed to match the native temporomandibular joint anatomy. The prosthesis was 3D printed, sterilized and implanted into the patient, and pain and function measured 12-months post-operatively. The prosthesis load response during a chewing-bite and maximum-force bite was evaluated using a personalized multi-body musculoskeletal model. Simulations were performed after perturbing condyle thickness, neck length and head sphericity. Increases in prosthetic condyle neck length malaligned the mandible and perturbed temporomandibular joint force. Changes in condylar component thickness greatly influenced fixation screw stress response, while a more eccentric condylar head increased prosthetic joint-contact loading. Post-operatively, the prosthetic temporomandibular joint surgery reduced patient pain from 7/10 to 1/10 on a visual analog scale, and increased intercisal opening distance from 22 mm to 38 mm. This study demonstrates effectiveness of a personalized prosthesis that may ultimately be adapted to treat a wide-range of end-stage temporomandibular joint conditions, and highlights sensitivity of prosthesis load response to changes in condylar geometry. Copyright © 2018 Elsevier Ltd. All rights reserved.
Bertocci, Gina E; Brown, Nathan P; Mich, Patrice M
2017-01-01
OBJECTIVE To evaluate effects of an orthosis on biomechanics of a cranial cruciate ligament (CrCL)-deficient canine stifle joint by use of a 3-D quasistatic rigid-body pelvic limb computer model simulating the stance phase of gait and to investigate influences of orthosis hinge stiffness (durometer). SAMPLE A previously developed computer simulation model for a healthy 33-kg 5-year-old neutered Golden Retriever. PROCEDURES A custom stifle joint orthosis was implemented in the CrCL-deficient pelvic limb computer simulation model. Ligament loads, relative tibial translation, and relative tibial rotation in the orthosis-stabilized stifle joint (baseline scenario; high-durometer hinge]) were determined and compared with values for CrCL-intact and CrCL-deficient stifle joints. Sensitivity analysis was conducted to evaluate the influence of orthosis hinge stiffness on model outcome measures. RESULTS The orthosis decreased loads placed on the caudal cruciate and lateral collateral ligaments and increased load placed on the medial collateral ligament, compared with loads for the CrCL-intact stifle joint. Ligament loads were decreased in the orthosis-managed CrCL-deficient stifle joint, compared with loads for the CrCL-deficient stifle joint. Relative tibial translation and rotation decreased but were not eliminated after orthosis management. Increased orthosis hinge stiffness reduced tibial translation and rotation, whereas decreased hinge stiffness increased internal tibial rotation, compared with values for the baseline scenario. CONCLUSIONS AND CLINICAL RELEVANCE Stifle joint biomechanics were improved following orthosis implementation, compared with biomechanics of the CrCL-deficient stifle joint. Orthosis hinge stiffness influenced stifle joint biomechanics. An orthosis may be a viable option to stabilize a CrCL-deficient canine stifle joint.
Sustained intra-articular release of celecoxib in an equine repeated LPS synovitis model.
Cokelaere, Stefan M; Plomp, Saskia G M; de Boef, Esther; de Leeuw, Mike; Bool, Sophie; van de Lest, Chris H A; René van Weeren, P; Korthagen, Nicoline M
2018-05-02
Synovial inflammation is an important characteristic of arthritic disorders like osteoarthritis and rheumatoid arthritis. Orally administered non-steroidal anti-inflammatory drugs (NSAIDs) such as celecoxib are among the most widely prescribed drugs to manage these debilitating diseases. Intra-articular delivery in biodegradable in situ forming hydrogels overcomes adverse systemic effects and prolongs drug retention in the joint. In this study two formulations of celecoxib (40 mg/g and 120 mg/g) in a propyl-capped PCLA-PEG-PCLA triblock copolymer were sequentially evaluated in a multiple LPS challenge equine synovitis model. Intra-articular release and systemic exposure to celecoxib and local changes at joint level were evaluated longitudinally. A single intra-articular injection of the high dose (HCLB)-gel or low dose (LCLB)-gel showed a sustained and controlled intra-articular release in both inflamed and healthy joints together with very low systemic exposure. Synovitis and lameness were moderate respectively very mild in this model due to the low concentration LPS (0.25 ng/joint). Both celecoxib formulations had a mild, transient effect on inflammatory and structural synovial fluid biomarkers but these returned to baseline within one week of administration. The HCLB-gel showed a significant inhibition in peak white blood cell concentration at 8 hours after LPS induction. Elevated levels of celecoxib were observed in the joint for up to 30 days but no overall anti-inflammatory effects could be observed, which was thought to be due to the moderate synovitis. As there were no long-term adverse effects, sustained intra-articular release of celecoxib from in situ forming hydrogels should be evaluated further for its effects on longer-term relief of inflammatory joint pain in humans and animals. Copyright © 2018. Published by Elsevier B.V.
Development and reliability of a preliminary Foot Osteoarthritis Magnetic Resonance Imaging Score
Halstead, Jill; Martín-Hervás, Carmen; Hensor, Elizabeth MA; McGonagle, Dennis; Keenan, Anne-Maree
2017-01-01
Objective Foot osteoarthritis (OA) is very common but under-investigated musculoskeletal condition and there is little consensus as to common MRI imaging features. The aim of this study was to develop a preliminary foot OA MRI score (FOAMRIS) and evaluate its reliability. Methods This preliminary semi-quantitative score included the hindfoot, midfoot and metatarsophalangeal joints. Joints were scored for joint space narrowing (JSN, 0-3), osteophytes (0-3), joint effusion-synovitis and bone cysts (present/absent). Erosions and bone marrow lesions (BMLs) were scored (0-3) and BMLs were evaluated adjacent to entheses and at sub-tendon sites (present/absent). Additionally, tenosynovitis was scored (0-3) and midfoot ligament pathology was scored (present/absent). Reliability was evaluated in 15 people with foot pain and MRI-detected OA using 3.0T MRI multi-sequence protocols and assessed using intraclass correlation coefficients (ICC) as an overall score and per anatomical site (see supplementary data). Results Intra-reader agreement (ICC) was generally good to excellent across the foot in joint features (JSN 0.94, osteophytes 0.94, effusion-synovitis 0.62 and cysts 0.93), bone features (BML 0.89, erosion 0.78, BML-entheses 0.79, BML sub-tendon 0.75) and soft-tissue features (tenosynovitis 0.90, ligaments 0.87). Inter-reader agreement was lower for joint features (JSN 0.60, osteophytes 0.41, effusion-synovitis 0.03) and cysts 0.65, bone features (BML 0.80, erosion 0.00, BML-entheses 0.49, BML sub-tendon -0.24) and soft-tissue features (tenosynovitis 0.48, ligaments 0.50). Conclusion This preliminary FOAMRIS demonstrated good intra-reader reliability and fair inter-reader reliability when assessing the total feature scores. Further development is required in cohorts with a range of pathologies and to assess the psychometric measurement properties. PMID:28572462
Efficient methods for joint estimation of multiple fundamental frequencies in music signals
NASA Astrophysics Data System (ADS)
Pertusa, Antonio; Iñesta, José M.
2012-12-01
This study presents efficient techniques for multiple fundamental frequency estimation in music signals. The proposed methodology can infer harmonic patterns from a mixture considering interactions with other sources and evaluate them in a joint estimation scheme. For this purpose, a set of fundamental frequency candidates are first selected at each frame, and several hypothetical combinations of them are generated. Combinations are independently evaluated, and the most likely is selected taking into account the intensity and spectral smoothness of its inferred patterns. The method is extended considering adjacent frames in order to smooth the detection in time, and a pitch tracking stage is finally performed to increase the temporal coherence. The proposed algorithms were evaluated in MIREX contests yielding state of the art results with a very low computational burden.
Evaluating the Upset Protrusion Joining (UPJ) Method to Join magnesium Castings to Dissimilar Metals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Logan, Stephen D.
2015-08-19
This presentation discusses advantages and best practices for incorporating magnesium in automotive component applications to achieve substantial mass reduction, as well as some of the key challenges with respect to joining, coating, and galvanic corrosion, before providing an introduction and status update of the U.S. Department of Energy and Department of Defense jointly sponsored Upset Protrusion Joining (UPJ) process development and evaluation project. This update includes sharing performance results of a benchmark evaluation of the self-pierce riveting (SPR) process for joining dissimilar magnesium (Mg) to aluminum (Al) materials in four unique coating configurations before introducing the UPJ concept and comparingmore » performance results of the joints made with the UPJ process to those made with the SPR process.« less
Mohammed, Nazmi A; Solaiman, Mohammad; Aly, Moustafa H
2014-10-10
In this work, various dispersion compensation methods are designed and evaluated to search for a cost-effective technique with remarkable dispersion compensation and a good pulse shape. The techniques consist of different chirp functions applied to a tanh fiber Bragg grating (FBG), a dispersion compensation fiber (DCF), and a DCF merged with an optimized linearly chirped tanh FBG (joint technique). The techniques are evaluated using a standard 10 Gb/s optical link over a 100 km long haul. The linear chirp function is the most appropriate choice of chirping function, with a pulse width reduction percentage (PWRP) of 75.15%, lower price, and poor pulse shape. The DCF yields an enhanced PWRP of 93.34% with a better pulse quality; however, it is the most costly of the evaluated techniques. Finally, the joint technique achieved the optimum PWRP (96.36%) among all the evaluated techniques and exhibited a remarkable pulse shape; it is less costly than the DCF, but more expensive than the chirped tanh FBG.
Evidence-based nursing leadership: Evaluation of a Joint Academic-Service Journal Club.
Duffy, Joanne R; Thompson, Diane; Hobbs, Terry; Niemeyer-Hackett, Nancy Lee; Elpers, Susan
2011-10-01
This article describes the importance of evidence-based nursing leadership in the development and evaluation of a joint academic-service nursing leadership journal club. The use of scientific evidence and the embracing of an environment of continuous learning are essential to quality practice; however, nursing leadership has been slow to apply evidence-based practice to their own work. A noontime monthly meeting schedule, incentivized by lunch, was organized as a nursing leadership journal club. Articles were selected and reviewed monthly, and the process was formally evaluated using a written evaluation at the end of year 1. Eighteen articles were appraised by the group with 6 topics identified. Positive results included increased knowledge, competence of the leader, and attainment of goals. Recommendations include revision of goals, plans to share leadership of the group, development of a rigorous evaluation of outcomes, and dissemination of findings. The journal club was valuable in increasing awareness of nursing leadership research, promoting leadership development, and improving competence in the performance of research appraisals. Process improvement and further study are needed to increase understanding regarding the benefits of leadership journal clubs.
2015-12-01
DOD, joint, or armed service component’s manuals , and other publications . Obviously, JCETs fall under the broader spectrum of security cooperation...NAVAL POSTGRADUATE SCHOOL MONTEREY, CALIFORNIA THESIS Approved for public release; distribution is unlimited JOINT COMBINED...No. 0704–0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing
Effects of simulated lightning on composite and metallic joints
NASA Technical Reports Server (NTRS)
Howell, W. E.; Plumer, J. A.
1982-01-01
The effects of simulated lightning strikes and currents on aircraft bonded joints and access/inspection panels were investigated. Both metallic and composite specimens were tested. Tests on metal fuel feed through elbows in graphite/epoxy structures were evaluated. Sparking threshold and residual strength of single lap bonded joints and sparking threshold of access/inspection panels and metal fuel feed through elbows are reported.
2011-12-01
Policy. Graduates will develop an ability to think strategically, analyze past operations, and apply historical lessons to future joint and combined...Naval Special Warfare Development Group O-## Officer, ## Rank OPMEP Officer, Professional Military Education Program OPTEMPO Operational Tempo...Marine Corps. 2 Joint Special Operations University (2007). MCSOCOM Prrof of Concept Deployment Evaluation Report. Hurlburt Field : Joint Special
Zhang, Jian-Bing; Chen, Bai-Cheng; Zhang, Jing; Wang, Zhi-Qiang; Yan, Chang-Bao
2010-11-15
to investigate if the cartilaginous surface and corresponding osseous contour of the patellofemoral joint match in the axial plane for providing theoretical basis with evaluating alignment of patellofemoral joint and designing the part of patellofemoral joint in knee prosthesis. from January 2009 to March 2010, 9 human cadaver knees were prepared, which chandra of patellofemoral joint didn't degenerate. Each specimen was sectioned in the axial plane at 20° to 30° knee flax. The cross-sections revealed characteristics in the bony anatomy and corresponding articular surface geometry of the patellofemoral joint in the axial plane. Evaluating parameters included osseous patella congruence angle (OPCA), chondral patella congruence angle (CPCA), patella chondral convex point parameter (PCCPP), patella subchondral osseous convex point parameter (PSOCPP), the parameters of the deepest (chondral or osseous) point of the intercondylar sulcus. After that, the osseous and cartilaginous contours and subchondral osseous contours of the patella in the axial plane were analyzed through MRI data of 11 patients who didn't degenerate in patellofemoral joint cartilage. Parameters as same as cadaver knees were compared. data from specimens of OPCA was (-4.5 ± 1.1)°, CPCA was (0.5 ± 0.8)°, PCCPP was 1.13 ± 0.11, PSOCPP was 1.67 ± 0.14, PCDPIS was 1.35 ± 0.28, PODPIS was 1.38 ± 0.33. Date from MRI of OPCA was (-3.8 ± 1.4)°, CPCA was (0.7 ± 1.0)°, PCCPP was 1.05 ± 0.21, PSOCPP was 1.73 ± 0.18, PCDPIS was 1.41 ± 0.21, PODPIS was 1.37 ± 0.27. The patella exhibited significant differences in the bony vs. chondral anatomy (P < 0.05), but the intercondylar sulcus nearly match in the bony vs. chondral anatomy. the cartilaginous surface and corresponding osseous contour of the patella don't match in the patellofemoral joint axial plane, but that of the trochlea nearly matches. This is very important for accurately evaluating alignment of patellofemoral joint because the normal osseous alignment of patellofemoral joint don't represent the normal alignment and helpful for designing the part of patellofemoral joint in knee prosthesis.
ERIC Educational Resources Information Center
Morris, Michael
2004-01-01
All evaluators face the challenge of striving to adhere to the highest possible standards of ethical conduct. Translating the AEA's Guiding Principles and the Joint Committee's Program Evaluation Standards into everyday practice, however, can be a complex, uncertain, and frustrating endeavor. Moreover, acting in an ethical fashion can require…
Ohio Route 50 Joint Sealant Experiment.
DOT National Transportation Integrated Search
2002-04-01
This is the third and Final Report for a research project that entailed the construction and evaluation to date of a stretch of a four-lane highway near Athens, Ohio. The main purpose of this project had been to evaluate concrete pavement in connecti...
Meeting the Needs of Students at Risk.
ERIC Educational Resources Information Center
Marchesi, Alvaro
1998-01-01
Identifies elements of successful approaches for at-risk students. Discusses three educational ideologies, five evaluation criteria that reflect overall school quality, joint use of internal and external evaluation, the importance of school culture, balancing common and culturally relevant curricula, professional development of teachers, classroom…
PACKAGE PLANTS FOR SMALL SYSTEMS: A FIELD STUDY
A joint field study was conducted by AWWA and the Drinking Water Research Division of USEPA to evaluate existing small community systems that use package plant technology. Forty-eight package plant systems representing a geographic and technological cross section were evaluated t...
Designing an International Joint Venture Negotiation Game.
ERIC Educational Resources Information Center
Kenkel, Phil; And Others
1996-01-01
Evaluates a simulation game that models management problems encountered in negotiating and managing international joint ventures. Designed to instruct executives of state-owned agribusinesses in Indonesia in abstract concepts such as partner rapport, transfer price conflicts, and marketing disagreements, its success suggests that simulation games…
DOT National Transportation Integrated Search
2004-12-01
This study evaluates the rehabilitation method utilizing the injection of Uretek (polyurethane) into the pavement structures on continuously reinforced concrete pavement (CRCP), jointed concrete pavement (JCP), and bridge approach slabs. The polyuret...
Structural factors of jointed plain concrete pavements : SPS-2--initial evaluation and analysis
DOT National Transportation Integrated Search
2005-04-01
The SPS-2 experiment, "Strategic Study of Structural Factors for Jointed Plain Concrete Pavements (JPCP)," is one of the key components of the Long Term Pavement Performance (LTPP) program. The main objective of this experiment is to determine the re...
Quality control/quality assurance testing for joint density and segregation of asphalt mixtures.
DOT National Transportation Integrated Search
2013-04-01
Longitudinal joint quality control/assurance is essential to the successful performance of asphalt pavements and it has received considerable amount of attention in recent years. The purpose of the study is to evaluate the level of compaction at the ...
Evaluation of the effectiveness of pressure relief joints in reinforced concrete pavements.
DOT National Transportation Integrated Search
1976-01-01
Reported are studies of the effectiveness of a 4-inch (100 mm) wide compressible material installed at 1,000-ft. (305 m) intervals in a jointed, reinforced concrete pavement in reducing pavement blowups. The studies were made on an Interstate highway...
DOT National Transportation Integrated Search
1975-02-01
Rail fasteners for concrete ties and direct fixation and bolted rail joints have been identified as key components for improving track performance. However, the lack of statistical load data limits the development of improved design criteria and eval...
Evaluating of NASA-Langley Research Center explosion seam welding
NASA Technical Reports Server (NTRS)
Otto, H. E.; Wittman, R.
1977-01-01
An explosion bonding technique to meet current fabrication requirements was demonstrated. A test program was conducted on explosion bonded joints, compared to fusion joints in 6061-T6 aluminum. The comparison was made in required fixtures, non-destructive testing, static strength and fatigue strength.
Medial joint space widening of the ankle in displaced Tillaux and Triplane fractures in children.
Gourineni, Prasad; Gupta, Asheesh
2011-10-01
Tillaux and Triplane fractures occur in children predominantly from external rotation mechanism. We hypothesized that in displaced fractures, the talus would shift laterally along with the distal fibula and the distal tibial epiphyseal fragment increasing the medial joint space. Consecutive cases evaluated retrospectively. Level I and Level II centers. Twenty-two skeletally immature patients with 14 displaced Triplane fractures and eight displaced Tillaux fractures were evaluated for medial joint space widening. Measurement of fracture displacement and medial joint space widening before and after intervention. Thirteen Triplane and six Tillaux fractures (86%) showed medial space widening of 1 to 9 mm and equal to the amount of fracture displacement. Reduction of the fracture reduced the medial space to normal. There were no known complications. Medial space widening of the ankle may be a sign of ankle fracture displacement. Anatomic reduction of the fracture reduces the medial space and may improve the results in Tillaux and Triplane fractures.
Effects Of Welding On The Fatigue Behaviour Of Commercial Aluminum AA-1100 Joints
NASA Astrophysics Data System (ADS)
Uthayakumar, M.; Balasubramanian, V.; Rani, Ahmad Majdi Abdul; Hadzima, Branislav
2018-04-01
Friction Stir Welding (FSW) is an budding solid state welding process, which is frequently used for joining aluminum alloys where materials can be joined without melt and recast. Therefore, when welding alloys through FSW the phase transformations occurs will be in the solid state form. The present work is aimed in evaluating the fatigue life of friction stir welded commercial grade aluminum alloy joints. The commercial grade AA1100 aluminum alloy of 12mm thickness plate is welded and the specimens are tested using a rotary beam fatigue testing machine at different stress levels. The stress versus number of cycles (S-N) curves was plotted using the data points. The Fatigue life of tungsten inert gas (TIG) and metal inert gas (MIG) welded joints was compared. The fatigue life of the weld joints was interrelated with the tensile properties, microstructure and micro hardness properties. The effects of the notches and welding processes are evaluated and reported.
Serio, Livia Maria; Palumbo, Davide; De Filippis, Luigi Alberto Ciro; Galietti, Umberto; Ludovico, Antonio Domenico
2016-02-23
A study of the Friction Stir Welding (FSW) process was carried out in order to evaluate the influence of process parameters on the mechanical properties of aluminum plates (AA5754-H111). The process was monitored during each test by means of infrared cameras in order to correlate temperature information with eventual changes of the mechanical properties of joints. In particular, two process parameters were considered for tests: the welding tool rotation speed and the welding tool traverse speed. The quality of joints was evaluated by means of destructive and non-destructive tests. In this regard, the presence of defects and the ultimate tensile strength (UTS) were investigated for each combination of the process parameters. A statistical analysis was carried out to assess the correlation between the thermal behavior of joints and the process parameters, also proving the capability of Infrared Thermography for on-line monitoring of the quality of joints.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cullen, W.K.; Keating, R.F.
1997-02-01
In the Spring and Fall of 1994, and the Spring of 1995, crack-like indications were found in the upper hybrid expansion joint (HEJ) region of Steam Generator (S/G) tubes which had been sleeved using Westinghouse HEJ sleeves. As a result of these findings, analytic and test evaluations were performed to assess the effect of the degradation on the structural, and leakage, integrity of the sleeve/tube joint relative to the requirements of the United States Nuclear Regulatory Commission`s (NRC) draft Regulatory Guide (RG) 1.121. The results of these evaluations demonstrated that tubes with implied or known crack-like circumferential parent tube indicationsmore » (PTIs) located 1.1 inches or farther below the bottom of the hardroll upper transition, have sufficient, and significant, integrity relative to the requirements of RG 1.121. Thus, the purpose of this report is to provide background information related to the justification of the modified tube repair boundary.« less
Roy, Jean-Sébastien; Bouyer, Laurent J; Langevin, Pierre; Mercier, Catherine
2017-11-01
To a large extent, management of musculoskeletal disorders has traditionally focused on structural dysfunctions found within the musculoskeletal system, mainly around the affected joint. While a structural-dysfunction approach may be effective for musculoskeletal conditions in some populations, especially in acute presentations, its effectiveness remains limited in patients with recurrent or chronic musculoskeletal pain. Numerous studies have shown that the human central nervous system can undergo plastic reorganizations following musculoskeletal disorders; however, they can be maladaptive and contribute to altered joint control and chronic pain. In this Viewpoint, the authors argue that to improve rehabilitation outcomes in patients with chronic musculoskeletal pain, a global view of the disorder that incorporates both central (neural) and peripheral (joint-level) changes is needed. The authors also discuss the challenge of evaluating and rehabilitating central changes and the need for large, high-level studies to evaluate approaches incorporating central and peripheral changes and emerging therapies. J Orthop Sports Phys Ther 2017;47(11):817-821. doi:10.2519/jospt.2017.0608.
Zhang, Bo; Liu, Wei; Zhang, Zhiwei; Qu, Yanping; Chen, Zhen; Albert, Paul S
2017-08-01
Joint modeling and within-cluster resampling are two approaches that are used for analyzing correlated data with informative cluster sizes. Motivated by a developmental toxicity study, we examined the performances and validity of these two approaches in testing covariate effects in generalized linear mixed-effects models. We show that the joint modeling approach is robust to the misspecification of cluster size models in terms of Type I and Type II errors when the corresponding covariates are not included in the random effects structure; otherwise, statistical tests may be affected. We also evaluate the performance of the within-cluster resampling procedure and thoroughly investigate the validity of it in modeling correlated data with informative cluster sizes. We show that within-cluster resampling is a valid alternative to joint modeling for cluster-specific covariates, but it is invalid for time-dependent covariates. The two methods are applied to a developmental toxicity study that investigated the effect of exposure to diethylene glycol dimethyl ether.
Serio, Livia Maria; Palumbo, Davide; De Filippis, Luigi Alberto Ciro; Galietti, Umberto; Ludovico, Antonio Domenico
2016-01-01
A study of the Friction Stir Welding (FSW) process was carried out in order to evaluate the influence of process parameters on the mechanical properties of aluminum plates (AA5754-H111). The process was monitored during each test by means of infrared cameras in order to correlate temperature information with eventual changes of the mechanical properties of joints. In particular, two process parameters were considered for tests: the welding tool rotation speed and the welding tool traverse speed. The quality of joints was evaluated by means of destructive and non-destructive tests. In this regard, the presence of defects and the ultimate tensile strength (UTS) were investigated for each combination of the process parameters. A statistical analysis was carried out to assess the correlation between the thermal behavior of joints and the process parameters, also proving the capability of Infrared Thermography for on-line monitoring of the quality of joints. PMID:28773246
Nanoparticle interactions with co-existing contaminants: joint toxicity, bioaccumulation and risk.
Deng, Rui; Lin, Daohui; Zhu, Lizhong; Majumdar, Sanghamitra; White, Jason C; Gardea-Torresdey, Jorge L; Xing, Baoshan
2017-06-01
With their growing production and application, engineered nanoparticles (NPs) are increasingly discharged into the environment. The released NPs can potentially interact with pre-existing contaminants, leading to biological effects (bioaccumulation and/or toxicity) that are poorly understood. Most studies on NPs focus on single analyte exposure; the existing literature on joint toxicity of NPs and co-existing contaminants is rather limited but beginning to develop rapidly. This is the first review paper evaluating the current state of knowledge regarding the joint effects of NPs and co-contaminants. Here, we review: (1) methods for investigating and evaluating joint effects of NPs and co-contaminants; (2) simultaneous toxicities from NPs co-exposed with organic contaminants, metal/metalloid ions, dissolved organic matter (DOM), inorganic ligands and additional NPs; and (3) the influence of NPs co-exposure on the bioaccumulation of organic contaminants and heavy metal ions, as well as the influence of contaminants on NPs bioaccumulation. In addition, future research needs are discussed so as to better understand risk associated with NPs-contaminant co-exposure.
NASA Astrophysics Data System (ADS)
Luo, Xiangcheng
Material contacts, including thermal, electrical, seating (fluid sealing and electromagnetic sealing) and mechanical (pressure) contacts, together with their interface materials, were, evaluated, and in some cases, improved beyond the state of the art. The evaluation involved the use of thermal, electrical and mechanical methods. For thermal contacts, this work evaluated and improved the heat transfer efficiency between two contacting components by developing various thermal interface pastes. Sodium silicate based thermal pastes (with boron nitride particles as the thermally conductive filler) as well as polyethylene glycol (PEG) based thermal pastes were developed and evaluated. The optimum volume fractions of BN in sodium silicate based pastes and PEG based pastes were 16% and 18% respectively. The contribution of Li+ ions to the thermal contact conductance in the PEG-based paste was confirmed. For electrical contacts, the relationship between the mechanical reliability and electrical reliability of solder/copper and silver-epoxy/copper joints was addressed. Mechanical pull-out testing was conducted on solder/copper and silver-epoxy/copper joints, while the contact electrical resistivity was measured. Cleansing of the copper surface was more effective for the reliability of silver-epoxy/copper joint than that of solder/copper joint. For sealing contacts, this work evaluated flexible graphite as an electromagnetic shielding gasket material. Flexible graphite was found to be at least comparable to conductive filled silicone (the state of the art) in terms of the shielding effectiveness. The conformability of flexible graphite with its mating metal surface under repeated compression was characterized by monitoring the contact electrical resistance, as the conformability is important to both electromagnetic scaling and fluid waling using flexible graphite. For mechanical contacts, this work focused on the correlation of the interface structure (such as elastic/plastic deformation, oxidation, strain hardening, passive layer damage, fracture, etc.) with the electrical contact resistance, which was measured in real time for contacts under dynamic compression, thus allowing both reversible and irreversible changes to be observed. The materials studied included metals (carbon steel, stainless steel, aluminum and copper), carbon fiber reinforced polymer-matrix composite (nylon-6), ceramic (mortar) and graphite, due to their relevance to fastening, concrete structures, electric brushes and electrical pressure contacts.
Mononen, Mika E; Jurvelin, Jukka S; Korhonen, Rami K
2015-01-01
Computational models can be used to evaluate the functional properties of knee joints and possible risk locations within joints. Current models with fibril-reinforced cartilage layers do not provide information about realistic human movement during walking. This study aimed to evaluate stresses and strains within a knee joint by implementing load data from a gait cycle in healthy and meniscectomised knee joint models with fibril-reinforced cartilages. A 3D finite element model of a knee joint with cartilages and menisci was created from magnetic resonance images. The gait cycle data from varying joint rotations, translations and axial forces were taken from experimental studies and implemented into the model. Cartilage layers were modelled as a fibril-reinforced poroviscoelastic material with the menisci considered as a transversely isotropic elastic material. In the normal knee joint model, relatively high maximum principal stresses were specifically predicted to occur in the medial condyle of the knee joint during the loading response. Bilateral meniscectomy increased stresses, strains and fluid pressures in cartilage on the lateral side, especially during the first 50% of the stance phase of the gait cycle. During the entire stance phase, the superficial collagen fibrils modulated stresses of cartilage, especially in the medial tibial cartilage. The present computational model with a gait cycle and fibril-reinforced biphasic cartilage revealed time- and location-dependent differences in stresses, strains and fluid pressures occurring in cartilage during walking. The lateral meniscus was observed to have a more significant role in distributing loads across the knee joint than the medial meniscus, suggesting that meniscectomy might initiate a post-traumatic process leading to osteoarthritis at the lateral compartment of the knee joint.
Bayer, Jörg; Neubauer, Jakob; Saueressig, Ulrich; Südkamp, Norbert Paul; Reising, Kilian
2016-04-01
The prevalence of paediatric pelvic injury is low, yet they are often indicative of accompanying injuries, and an instable pelvis at presentation is related to long-term poor outcome. Judging diastasis of the sacroiliac joint in paediatric pelvic computed tomography is challenging, as information on their normal appearance is scarce. We therefore sought to generate age- and gender-related standard width measurements of the sacroiliac joint in children for comparison. A total of 427 pelvic computed tomography scans in paediatric patients (<18 years old) were retrospectively evaluated. After applying exclusion criteria, 350 scans remained for measurements. Taking a standard approach we measured the sacroiliac joint width bilaterally in axial and coronal planes. We illustrate age- and gender-related measurements of the sacroiliac joint width as a designated continuous 3rd, 15th, 50th, 85th and 97th centile graph, respectively. Means and standard deviations in the joint width are reported for four age groups. There are distinct changes in the sacroiliac joint's appearance during growth. In general, male children exhibit broader sacroiliac joints than females at the same age, although this difference is significant only in the 11 to 15-year-old age group. The sacroiliac joint width in children as measured in coronal and axial CT scans differs in association with age and gender. When the sacroiliac joint width is broader than the 97th centile published in our study, we strongly encourage considering a sacroiliac joint injury. Copyright © 2016 Elsevier Ltd. All rights reserved.
Thienpont, E; Vanden Berghe, A; Schwab, P E; Forthomme, J P; Cornu, O
2016-10-01
To utilize the 'Forgotten Joint' Score (FJS), a 12-item questionnaire analysing the ability to forget the joint, for comparing preoperative status in osteoarthritic patients scheduled for total hip arthroplasty (THA) or total knee arthroplasty (TKA). Higher scores represent a better result with a maximum of 100. The hypothesis of this study was that a preoperative difference in favour of hip arthritis could eventually explain why THA is cited more often as a forgotten joint than TKA. A prospective cohort study was conducted in 150 patients with either tricompartmental knee (n = 75) or hip osteoarthritis (n = 75). Patients completed FJS-12 scores preoperatively and 1 year postoperatively. A similar preoperative FJS-12 was observed for hip (22 (15)) and knee osteoarthritis (24 (17)) (n.s.). The postoperative FJS-12 score was significantly higher for THA (80 (24)) than for TKA (70 (27)) (p < 0.05). High reliability after 6 weeks was observed for the preoperative FJS-12 test-retest reliability (ICC = 0.87) in TKA. A preoperative floor effect of 15 % in THA and 0 % in TKA was found as well as a postoperative ceiling effect of 33 % in THA and 9 % in TKA. The clinical relevance of utilizing the FJS-12 as an instrument to evaluate outcome is strongly proposed for knee arthroplasty. In general, one is not aware of a healthy joint during the ADL, and it can therefore be regarded as 'forgotten'. The preoperative FJS-12 Score is a powerful tool to provide patients with clearer insights into their positive evolution after surgery. The use of the FJS-12 in THA is a topic for further research, as this study found that floor and ceiling effects limit its usefulness in studies evaluating clinical outcome in this area. II.
Bisi, Melissa Cláudia; do Prado, Aline Defaveri; Piovesan, Deise Marcela; Bredemeier, Markus; da Silveira, Inês Guimarães; Mendonça, José Alexandre; Staub, Henrique Luiz
2017-04-01
Ultrasonography (US) is a useful tool for the evaluation of sinovial vascularization and proliferation in rheumatoid arthritis (RA). Accordingly, resistive index (RI) on spectral Doppler (sD) US provides a quantitative analysis of vascular inflammation, but its utility in the evaluation of RA activity has not been established. Our objective was to determine the association of RI with other US parameters of synovitis and with clinical disease activity in established RA. Patients with positive power Doppler (pD) were included in a prospective cross-sectional study. Disease activity and disability were evaluated using the Disease Activity Score in 28-joints (DAS28) and Health Assessment Questionnaire (HAQ), respectively. Gray scale (GS) synovitis, pD, and sD analyses were performed by one of two examiners in wrists and the second and third metacarpophalangeal and proximal interphalangeal joints. The 10-joint GS and 10-joint pD scores and mean RI were then calculated. Weighted kappa (WK) values were employed to assess interobserver reability, and correlations were tested using the Spearman coefficient. Ninety-five RA patients (median duration of disease of 7 years and mean DAS28 of 4.32 ± 1.66) were included. WK values in real-time US were 0.77 for synovitis, 0.87 for pD, and 0.68 for RI. There were no significant correlations of RI with 10-joint GS, 10-joint pD, DAS28, joint counts, or HAQ (P > 0.10 for all tests). Patients in remission had a mean RI similar to those with high disease activity (0.62 ± 0.10, n = 15 versus 0.63 ± 0.13, n = 34, respectively). The addition of the RI score did not seem to improve US performance in patients with established RA.
Evaluating Research Administration: Methods and Utility
ERIC Educational Resources Information Center
Marina, Sarah; Davis-Hamilton, Zoya; Charmanski, Kara E.
2015-01-01
Three studies were jointly conducted by the Office of Research Administration and Office of Proposal Development at Tufts University to evaluate the services within each respective office. The studies featured assessments that used, respectively, (1) quantitative metrics; (2) a quantitative satisfaction survey with limited qualitative questions;…
Prevention of the Posttraumatic Fibrotic Response in Joints
2016-12-01
fibrotic deposits. Evaluation of the efficacy of the proposed approach was achieved by biochemical assays of collagen content and composition, then by...the amount of cross-links in collagen deposits, by histological assays of involved tissues, and by biomechanical evaluation of the flexion contracture...batches collected from each bioreactor run were evaluated by analyzing the binding affinity of the purified antibody to procollagen I standard that
Prevention of the Posttraumatic Fibrotic Response in Joints
2016-12-01
received the therapeutic antibody to minimize the formation of excessive fibrotic deposits. Evaluation of the efficacy of the proposed approach was...involved tissues, and by biomechanical evaluation of the flexion contracture. Appropriate controls were also included [5,6]. Note, that this is a...of the combined pool of the ACA batches collected from each bioreactor run were evaluated by analyzing the binding affinity of the purified antibody
ERIC Educational Resources Information Center
Hopkins, Paul
2016-01-01
The purpose of this study was to determine how K-12 public school teachers perceive the use of student performance data in teacher evaluations. The proprietary, utility, feasibility, and accuracy standards created by the Joint Committee on Standards for Education Evaluation served as a framework for the study. An online survey was deployed to a…
DOT National Transportation Integrated Search
2016-06-26
The datasets in this zip file are in support of Intelligent Transportation Systems Joint Program Office (ITS JPO) report FHWA-JPO-16-385, "Analysis, Modeling, and Simulation (AMS) Testbed Development and Evaluation to Support Dynamic Mobility Applica...
Marcus, Bernd; Wagner, Uwe
2007-04-01
In the present research, we investigated the joint impact of selected antecedents of counterproductive work behavior (CWB). A sample of German apprentices reported on their CWB and completed measures of situational evaluations (vocational preference, level and constructiveness of job satisfaction) believed to trigger CWB and of dispositional motivators (measured by integrity test subscales) and controls (self-control and another subset of integrity scales) of CWB. All predictors investigated showed the expected bivariate relationships with CWB. Multivariate analyses revealed that the triggering effect of an unfavorable vocational choice on CWB was fully mediated by job satisfaction. When predictors were aggregated, a composite of dispositional control variables had the largest effect on CWB and moderated the effects of motivational dispositions and situational evaluations. These results extend the knowledge on antecedents of CWB by investigating previously overlooked variables and samples and partially replicate recent findings on the joint impact of dispositions and work-related evaluations on CWB. Copyright (c) 2007 APA, all rights reserved.
DOT National Transportation Integrated Search
2017-01-01
Connections, closure pours, and joints in bridges are often sources of distress because of cracks and openings. Wide separation facilitates the penetration of harmful solutions that can lead to costly repairs. Cracks are caused by volumetric changes ...
30 CFR 18.33 - Finish of surface joints.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Finish of surface joints. 18.33 Section 18.33 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design...
The Cheshire Jet: Harnessing Metamaterials to Achieve an Optical Stealth Capability
2010-07-01
Prometheus Books, 2005. Hamilton, Dave. Address. 23rd Annual National Test and Evaluation Conference, Hilton Head Island, SC, 15 March 2007. http...ment 2008: Challenges and Implications for the Future Joint Force. Norfolk, VA: Center for Joint Futures, 25 November 2008. Valentine, Jason , Shuang
DOT National Transportation Integrated Search
1982-01-01
A study of the installation and three-year performance evaluation of a fabric-reinforced bituminous concrete overlay of a jointed concrete pavement is reported. The fabric, a polypropylene in an asphaltic mastic, was shown to act as a significant det...
Gropp, Kathryn E; Carlson, Cathy S; Evans, Mark G; Bagi, Cedo M; Reagan, William J; Hurst, Susan I; Shelton, David L; Zorbas, Mark A
2018-01-01
Tanezumab, an anti-nerve growth factor (NGF) antibody, is in development for management of chronic pain. During clinical trials of anti-NGF antibodies, some patients reported unexpected adverse events requiring total joint replacements, resulting in a partial clinical hold on all NGF inhibitors. Three nonclinical toxicology studies were conducted to evaluate the effects of tanezumab or the murine precursor muMab911 on selected bone and joint endpoints and biomarkers in cynomolgus monkeys, Sprague-Dawley rats, and C57BL/6 mice. Joint and bone endpoints included histology, immunohistochemistry, microcomputed tomography (mCT) imaging, and serum biomarkers of bone physiology. Responses of bone endpoints to tanezumab were evaluated in monkeys at 4 to 30 mg/kg/week for 26 weeks and in rats at 0.2 to 10 mg/kg twice weekly for 28 days. The effects of muMab911 at 10 mg/kg/week for 12 weeks on selected bone endpoints were determined in mice. Tanezumab and muMab911 had no adverse effects on any bone or joint parameter. There were no test article-related effects on bone or joint histology, immunohistochemistry, or structure. Reversible, higher osteocalcin concentrations occurred only in the rat study. No deleterious effects were observed in joints or bones in monkeys, rats, or mice administered high doses of tanezumab or muMab911.
A Thumb Carpometacarpal Joint Coordinate System Based on Articular Surface Geometry
Halilaj, Eni; Rainbow, Michael J.; Got, Christopher; Moore, Douglas C.; Crisco, Joseph J.
2013-01-01
The thumb carpometacarpal (CMC) joint is a saddle-shaped articulation whose in vivo kinematics can be explored more accurately with computed tomography (CT) imaging methods than with previously used skin-based marker systems. These CT-based methods permit a detailed analysis of the morphology of the joint, and thus the prominent saddle-shaped geometry can be used to define a coordinate system that is inherently aligned with the primary directions of motion at the joint. The purpose of this study was to develop a CMC joint coordinate systems that is based on the computed principal directions of curvature on the trapezium and the first metacarpal. We evaluated the new coordinate system using bone surface models segmented from the CT scans of twenty-four healthy subjects. An analysis of sensitivity to the manual selection of articular surfaces resulted in mean orientation differences of 0.7±0.7° and mean location differences of 0.2±0.1mm. Inter-subject variability, which mostly emanates from anatomical differences, was evaluated with whole bone registration and resulted in mean orientation differences of 3.1±2.7° and mean location differences of 0.9±0.5mm. The proposed joint coordinate system addresses concerns of repeatability associated with bony landmark identification and provides a robust platform for describing the complex kinematics of the CMC joint. PMID:23357698
Flight set 360L007 (STS-33) insulation component. Volume 3: Final release
NASA Technical Reports Server (NTRS)
Hicken, Steve
1990-01-01
Volume 3 of this postfire report deals with the insulation component of the RSRM. The report is released twice for each flight set. The interim release contract date is on or before 60 days after the last field joint or nozzle to case joint is disassembled at KSC and contain the results of the KSC visual evaluation. The data contained in Volume 3 interim release supersedes the insulation data presented in the KSC 10 day report. The final release contract data is on or before 60 days after the last factory joint is disassembled at the Clearfield H-7 facility and contains the results of all visual evaluations and a thermal safety factor analysis. The data contained in the Volume 3 final release supersedes the interim release and the insulation data presented in the Clearfield 10 day report.
Brazing of Stainless Steels to Yttria Stabilized Zirconia (YSZ) Using Silver -Base Brazes
NASA Technical Reports Server (NTRS)
Singh, Mrityunjay; Shpargel, Tarah P.; Asthana, Rajiv
2005-01-01
Three silver-base brazes containing either noble metal palladium (Palcusil-10 and Palcusil-15) or active metal titanium (Ticusil) were evaluated for high-temperature oxidation resistance, and their effectiveness in joining yttria stabilized zirconia (YSZ) to a corrosion-resistant ferritic stainless steel. Thermogravimetric analysis (TGA), and optical- and scanning electron microscopy (SEM) coupled with energy dispersive spectrometry (EDS) were used to evaluate the braze oxidation behavior and the structure and chemistry of the YSZ/braze/steel joints. The effect of the braze type and processing conditions on the interfacial microstructure and composition of the joint regions is discussed with reference to the chemical changes that occur at the interface. It was found that chemical interdiffusion of the constituents of YSZ, steel and the brazes led to compositional changes and/or interface reconstruction, and metallurgically sound joints.
NASA Astrophysics Data System (ADS)
Wang, Peitao; Cai, Meifeng; Ren, Fenhua; Li, Changhong; Yang, Tianhong
2017-07-01
This paper develops a numerical approach to determine the mechanical behavior of discrete fractures network (DFN) models based on digital image processing technique and particle flow code (PFC2D). A series of direct shear tests of jointed rocks were numerically performed to study the effect of normal stress, friction coefficient and joint bond strength on the mechanical behavior of joint rock and evaluate the influence of micro-parameters on the shear properties of jointed rocks using the proposed approach. The complete shear stress-displacement curve of the DFN model under direct shear tests was presented to evaluate the failure processes of jointed rock. The results show that the peak and residual strength are sensitive to normal stress. A higher normal stress has a greater effect on the initiation and propagation of cracks. Additionally, an increase in the bond strength ratio results in an increase in the number of both shear and normal cracks. The friction coefficient was also found to have a significant influence on the shear strength and shear cracks. Increasing in the friction coefficient resulted in the decreasing in the initiation of normal cracks. The unique contribution of this paper is the proposed modeling technique to simulate the mechanical behavior of jointed rock mass based on particle mechanics approaches.
SRB Environment Evaluation and Analysis. Volume 2: RSRB Joint Filling Test/Analysis Improvements
NASA Technical Reports Server (NTRS)
Knox, E. C.; Woods, G. Hamilton
1991-01-01
Following the Challenger accident a very comprehensive solid rocket booster (SRB) redesign program was initiated. One objective of the program was to develop expertise at NASA/MSFC in the techniques for analyzing the flow of hot gases in the SRB joints. Several test programs were undertaken to provide a data base of joint performance with manufactured defects in the joints to allow hot gases to fill the joints. This data base was used also to develop the analytical techniques. Some of the test programs were Joint Environment Simulator (JES), Nozzle Joint Environment Simulator (NJES), Transient Pressure Test Article (TPTA), and Seventy-Pound Charge (SPC). In 1988 the TPTA test hardware was moved from the Utah site to MSFC and several RSRM tests were scheduled, to be followed by tests for the ASRM program. REMTECH Inc. supported these activities with pretest estimates of the flow conditions in the test joints, and post-test analysis and evaluation of the measurements. During this support REMTECH identified deficiencies in the gas-measurement instrumentation that existed in the TPTA hardware, made recommendations for its replacement, and identified improvements to the analytical tools used in the test support. Only one test was completed under the TPTA RSRM test program, and those scheduled for the ASRM were rescheduled to a time after the expiration of this contract. The attention of this effort was directed toward improvements in the analytical techniques in preparation for when the ASRM program begins.
Validation study of the Forgotten Joint Score-12 as a universal patient-reported outcome measure.
Matsumoto, Mikio; Baba, Tomonori; Homma, Yasuhiro; Kobayashi, Hideo; Ochi, Hironori; Yuasa, Takahito; Behrend, Henrik; Kaneko, Kazuo
2015-10-01
The Forgotten Joint Score-12 (FJS-12) is for patients to forget their artificial joint and is reportedly a useful patient-reported outcome tool for artificial joints. The purpose of this study was to determine whether the FJS-12 is as useful as the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) or the Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ) in Japan. All patients who visited our hospital's hip joint specialists following unilateral THA from August 2013 to July 2014 were evaluated. Medical staff members other than physicians administered three questionnaires. Items evaluated were (1) the reliability of the FJS-12 and (2) correlations between the FJS-12 and the total and subscale scores of the WOMAC or JHEQ. Of 130 patients, 22 were excluded. Cronbach's α coefficient was 0.97 for the FJS-12. The FJS-12 showed a significantly lower score than the WOMAC or JHEQ (p < 0.01). The FJS-12 was moderately correlated with the total WOMAC score (r = 0.522) and its subscale scores for "stiffness" (r = 0.401) and "function" (r = 0.539) and was weakly correlated with the score for "pain" (r = 0.289). The FJS-12 was favorably correlated with the total JHEQ score (r = 0.686) and its subscale scores (r = 0.530-0.643). The FJS-12 was correlated with and showed reliability similar to that of the JHEQ and WOMAC. The FJS-12, which is not affected by culture or lifestyle, may be useful in Japan.
Painful lumbar spondylolysis among pediatric sports players: a pilot MRI study.
Sairyo, Koichi; Sakai, Toshinori; Mase, Yasuyoshi; Kon, Tamiyo; Shibuya, Isao; Kanamori, Yasuo; Kosugi, Tatsuo; Dezawa, Akira
2011-11-01
For children and adolescents who are very active athletes, fresh lumbar spondylolysis is the main pathologic cause of lower back pain (LBP). However, regarding the terminal-stage spondylolysis (pars defect), there have been few studies to clarify the pathomechanism of LBP. The purpose of this study is to clarify the cause of LBP associated with pars defects in athletes. This is the first report showing a possible pathomechanism of LBP in active athletes with painful pars defect. Six pediatric athletes (5 boys and 1 girl) below 18 years old with painful bilateral lumbar spondylolysis were evaluated. In all cases, spondylolysis was identified as terminal stage (pseudoarthrosis) on CT scan. To evaluate the inflammation around the pars defects, short time inversion recovery (STIR) MRI was performed along with the sagittal section. Fluid collection, which is an indicator of inflammatory events, was evaluated in 12 pars defects as well as in 12 cranial and caudal adjoining facet joints. Inflammation (i.e., fluid collection) was observed in all 12 pars defects in six subjects at the pseudoarthrotic pars defects. In terms of facet joints, 7 of 12 (58%) pars defects showed fluid collection at the cranial and/or caudal adjoining joints on STIR MRI. The present study showed that inflammation was always present at the pars defects and in some cases at the adjoining facet joints. Thus, it is not difficult to understand how, during sports activity, inflammation may first occur at the pseudoarthrotic site and then spread to the adjoining facet joints. This mechanism could cause LBP associated with terminal-stage (pseudoarthrotics) spondylolysis in athletes.
Intra-articular clearance of labeled dextrans from naive and arthritic rat knee joints.
Mwangi, Timothy K; Berke, Ian M; Nieves, Eduardo H; Bell, Richard D; Adams, Samuel B; Setton, Lori A
2018-05-26
Determine the effects of arthritis on the trans-synovial clearance of small and large model compounds following local delivery to the knee joint in a rat model. Intra-articular delivery was studied in rat knee joints in an osteoarthritis model of joint instability (medial collateral ligament and meniscus transection model or MMT). Fluorescently-labeled 10 kDa or 500 kDa dextran was injected in the arthritic or unoperated control (naive) joints 3 weeks after surgical destabilization, and the temporal clearance pattern was evaluated via in vivo regional fluorescence imaging, dextran concentrations in plasma and draining lymph nodes, and by quantification of fluorescence in histological synovium sections. Together these data were used to evaluate the effect of osteoarthritis and solute size on the rate of drug clearance from the joint. Clearance of 10 kDa dextran from the joint space quantified using in vivo fluorescence imaging of the knee joint region was not significantly different between naive and MMT joints. In contrast, clearance of 500 kDa dextran was significantly reduced for MMT joints when compared to naive joints by fluorescence in vivo imaging. Drug accumulation in lymph nodes and plasma were lower for the 500 kDa dextran as compared to 10 kDa dextran, and lymph node levels were further reduced with the presence of osteoarthritis. Furthermore, synovium was significantly thicker in MMT joints than in naive joints and image analysis of joint tissue sections revealed different trans-synovial distributions of 10 and 500 kDa dextran. Large macromolecules were retained in the arthritic joint longer than in the healthy joint, while smaller molecules were cleared similarly in healthy and arthritic joints. In vivo fluorescence imaging, plasma and lymph node concentrations, and spatial distributions of drug fluorescence identified differences in higher molecular weight clearance between naive and arthritic disease states. Findings may relate to a thickening of synovium for joints with induced arthritis, and support the concept that intra-articular drug delivery effectiveness may vary with the state of joint pathology. Copyright © 2018 Elsevier B.V. All rights reserved.
Guermazi, Ali; Hunter, David J; Roemer, Frank W
2009-02-01
Osteoarthritis is the most common joint disorder worldwide, and it has an enormous socioeconomic impact both in the United States and throughout the world. Conventional radiography is the simplest and least expensive imaging method for assessing osteoarthritis of the knee. Radiography is able to directly visualize osseous features of osteoarthritis, including marginal osteophytes, subchondral sclerosis, and subchondral cysts, and it is used in clinical practice to confirm the diagnosis of osteoarthritis and to monitor progression of the disease. However, the assessment of joint-space width provides only an indirect estimate of cartilage thickness and meniscal integrity. Magnetic resonance imaging, with its unique ability to examine the joint as a whole organ, holds great promise with regard to the rapid advancement of knowledge about the disease and the evaluation of novel treatment approaches. Magnetic resonance imaging has been applied widely in quantitative morphometric cartilage assessment, and compositional measures have been introduced that evaluate chondral integrity. In addition, magnetic resonance imaging-based validated semiquantitative whole-organ scoring methods have been applied for cross-sectional and longitudinal joint evaluation. This review describes currently applied radiographic and magnetic resonance imaging staging and scoring methods for the assessment of osteoarthritis of the knee and focuses on the strengths and weaknesses of the two modalities with regard to their use in clinical trials and epidemiologic studies.
Supraspinatus tendinosis associated with biceps brachii tendon displacement in a dog.
Fransson, Boel A; Gavin, Patrick R; Lahmers, Kevin K
2005-11-01
A 4-year-old spayed female Australian Cattle Dog (Blue Heeler) was evaluated because of right forelimb lameness of 5 months' duration. Orthopedic evaluation revealed signs of pain localized to the cranial aspects of both shoulder joints. Via magnetic resonance imaging, the mass of the supraspinatus tendon insertion in both shoulder joints was increased, compared with findings in cadavers of clinically normal dogs; additional imaging procedures revealed that, compared with clinically normal tendons, the tendon had increased signal intensity that was consistent with increased fluid content. The increased supraspinatus tendon mass in each shoulder joint was associated with medial displacement of the biceps brachii tendon, which was more severe in the right limb. Arthroscopic evaluations of both shoulder joints revealed no abnormalities. The dog underwent surgery, and the abnormal parts of the tendons were resected. The most prominent finding on histologic examination of excised tissues was severe myxomatous degeneration. The lameness resolved, and at 22 months after surgery, the dog was reported to have had no recurrence of lameness. The clinical signs and histologic appearance of the tendons in this dog strongly resemble findings associated with tendinosis in humans. Decompression of the biceps brachii tendon may have contributed to the successful outcome after surgery in this dog. Supraspinatus tendinosis should be considered among the differential diagnoses in dogs with uni- or bilateral forelimb lameness.
Peimer, Clayton A; Blazar, Philip; Coleman, Stephen; Kaplan, F Thomas D; Smith, Ted; Tursi, James P; Cohen, Brian; Kaufman, Gregory J; Lindau, Tommy
2013-01-01
To evaluate long-term efficacy and safety of collagenase clostridium histolyticum (CCH) after the third year of a 5-year nontreatment follow-up study, Collagenase Option for Reduction of Dupuytren Long-Term Evaluation of Safety Study. This study enrolled Dupuytren contracture patients from 5 previous clinical studies. Beginning 2 years after their first CCH injection, we re-evaluated patients annually for joint contracture and safety. Recurrence in a previously successfully treated joint (success = 0° to 5° contracture after CCH administration) was defined as 20° or greater worsening in contracture in the presence of a palpable cord or medical/surgical intervention to correct new or worsening contracture. We assessed partially corrected joints (joints reduced 20° or more from baseline contracture but not to 0° to 5°) for nondurable response, also defined as 20° or greater worsening of contracture or medical/surgical intervention. Of 1,080 CCH-treated joints (648 metacarpophalangeal [MCP]; 432 proximal interphalangeal [PIP]; n = 643 patients), 623 (451 MCP, 172 PIP) had achieved 0° to 5° contracture in the original study. Of these joints, 35% (217 of 623) recurred (MCP 27%; PIP 56%). Of these recurrences, an intervention was performed in 7%. Of the 1,080 CCH-treated joints, 301 were partially corrected in the original study. Of these, 50% (150 of 301; MCP: 38% [57 of 152]; PIP: 62% [93 of 149]) had nondurable response. We identified no new long-term or serious adverse events attributed to CCH during follow-up. Anti-clostridial type I collagenase and/or anti-clostridial type II collagenase antibodies were reported for 96% or more of patients who received 2 or more CCH injections and 82% who received 1 injection. The recurrence rate, which is comparable to other standard treatments, and the absence of long-term adverse events 3 years after initial treatment indicate that CCH is an effective and safe treatment for Dupuytren contracture. Most successfully treated joints had a contracture well below the threshold for surgical intervention 3 years after treatment. Recurrence rates among successfully treated joints were lower than nondurable response rates among partially corrected joints. Therapeutic IV. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Petruseviciene, Daiva; Krisciūnas, Aleksandras; Sameniene, Jūrate
2002-01-01
In this article we analyze influence of rehabilitation methods in treatment of arm lymphedema. In Kaunas oncological hospital were examined 60 women after surgery for breast cancer. The work objective was to evaluate efficiency of rehabilitation methods in treatment of arm lymphedema and in evaluate movement amplitude of shoulder joint. Two groups of women depending on rehabilitation start were evaluated. The same methods of rehabilitation were applied to both groups: physical therapy, electrostimulation, massage, lymphodrainage with apparate. Our study indicated that women, who were treated at early period of rehabilitation (3 months), showed statistically significantly (p < 0.01) better results in increase of movement amplitude of shoulder joint. However, results of treatment of arm lymphedema, comparing with women who started rehabilitation after 12 months, were equally successful--results were not statistically significantly better (p > 0.05).
Patkowski, Mateusz; Królikowska, Aleksandra; Reichert, Paweł
2016-01-01
The reconstruction of the anterior cruciate ligament (ACL) of the knee joint is a standard in ACL complete rupture treatment in athletes. One of the weakest points of this procedure is tibial fixation of grafts. The aim was, firstly, to evaluate patients 3-4 years after primary ACL reconstruction with the use of autologous ipsilateral STGR grafts and with tibial fixation using a bioabsorbable interference screw composed of PLLA-HA or WasherLoc, comparing the postoperative result to the preoperative condition and, secondly, to compare the results between the two groups of patients with different tibial fixation. Group I consisted of 20 patients with a bioabsorbable interference screw composed of PLLA-HA tibial fixation. In Group II, there were 22 patients after ACL reconstruction with the use of WasherLoc tibial fixation. The Lachman test, pivot-shift test, Lysholm Knee Scoring Scale and 2000 International Knee Documentation Committee (2000 IKDC) Subjective Knee Evaluation Form were used to evaluate the results. The intra-group comparison of the results of the 2000 IKDC Subjective Knee Evaluation Form and Lysholm Knee Scoring Scale obtained in the groups studied showed statistically significant differences between the evaluation performed preoperatively and postoperatively. The inter-group comparison of the results of the 2000 IKDC Subjective Knee Evaluation Form and Lysholm Knee Scoring Scale obtained postoperatively showed no statistically significant differences between the two groups. An evaluation 3-4 years after ACL reconstruction with the use of autologous ipsilateral STGR grafts demonstrated significant progress from the preoperative condition to the postoperative result in patients with tibial fixation using a bioabsorbable interference screw composed of PLLA-HA as well as in patients with WasherLoc tibial fixation. There were no differences found between the two groups of patients after ACL reconstruction in terms of manual stability testing or a subjective assessment of knee joint outcomes.
Surrogate modeling of deformable joint contact using artificial neural networks.
Eskinazi, Ilan; Fregly, Benjamin J
2015-09-01
Deformable joint contact models can be used to estimate loading conditions for cartilage-cartilage, implant-implant, human-orthotic, and foot-ground interactions. However, contact evaluations are often so expensive computationally that they can be prohibitive for simulations or optimizations requiring thousands or even millions of contact evaluations. To overcome this limitation, we developed a novel surrogate contact modeling method based on artificial neural networks (ANNs). The method uses special sampling techniques to gather input-output data points from an original (slow) contact model in multiple domains of input space, where each domain represents a different physical situation likely to be encountered. For each contact force and torque output by the original contact model, a multi-layer feed-forward ANN is defined, trained, and incorporated into a surrogate contact model. As an evaluation problem, we created an ANN-based surrogate contact model of an artificial tibiofemoral joint using over 75,000 evaluations of a fine-grid elastic foundation (EF) contact model. The surrogate contact model computed contact forces and torques about 1000 times faster than a less accurate coarse grid EF contact model. Furthermore, the surrogate contact model was seven times more accurate than the coarse grid EF contact model within the input domain of a walking motion. For larger input domains, the surrogate contact model showed the expected trend of increasing error with increasing domain size. In addition, the surrogate contact model was able to identify out-of-contact situations with high accuracy. Computational contact models created using our proposed ANN approach may remove an important computational bottleneck from musculoskeletal simulations or optimizations incorporating deformable joint contact models. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Surrogate Modeling of Deformable Joint Contact using Artificial Neural Networks
Eskinazi, Ilan; Fregly, Benjamin J.
2016-01-01
Deformable joint contact models can be used to estimate loading conditions for cartilage-cartilage, implant-implant, human-orthotic, and foot-ground interactions. However, contact evaluations are often so expensive computationally that they can be prohibitive for simulations or optimizations requiring thousands or even millions of contact evaluations. To overcome this limitation, we developed a novel surrogate contact modeling method based on artificial neural networks (ANNs). The method uses special sampling techniques to gather input-output data points from an original (slow) contact model in multiple domains of input space, where each domain represents a different physical situation likely to be encountered. For each contact force and torque output by the original contact model, a multi-layer feed-forward ANN is defined, trained, and incorporated into a surrogate contact model. As an evaluation problem, we created an ANN-based surrogate contact model of an artificial tibiofemoral joint using over 75,000 evaluations of a fine-grid elastic foundation (EF) contact model. The surrogate contact model computed contact forces and torques about 1000 times faster than a less accurate coarse grid EF contact model. Furthermore, the surrogate contact model was seven times more accurate than the coarse grid EF contact model within the input domain of a walking motion. For larger input domains, the surrogate contact model showed the expected trend of increasing error with increasing domain size. In addition, the surrogate contact model was able to identify out-of-contact situations with high accuracy. Computational contact models created using our proposed ANN approach may remove an important computational bottleneck from musculoskeletal simulations or optimizations incorporating deformable joint contact models. PMID:26220591
Bear, Brian J; Peimer, Clayton A; Kaplan, F Thomas D; Kaufman, Gregory J; Tursi, James P; Smith, Ted
2017-05-01
Collagenase Clostridium histolyticum (CCH) is approved for the treatment of adults with Dupuytren contracture with a palpable cord. This open-label, phase 4 study evaluated the safety and efficacy of CCH for the retreatment of recurrent contractures in joints that were previously effectively treated with CCH. Patients participating in a long-term follow-up study who had contracture recurrence (increased ≥ 20° with a palpable cord) after successful treatment in the previous study were eligible. Recurrent joint contractures were treated with up to 3 CCH injections (∼ 1 month apart). Patients were followed for 1 year to evaluate safety. Assessments included change in joint contracture, range of motion, and the percentage of joints that achieved contracture of 5° or less at day 30 after the last injection. The efficacy analysis included 51 patients with 1 treated joint per patient (31 metacarpophalangeal, 20 proximal interphalangeal). A total of 35 joints (69%) received 1 injection, 12 (24%) received 2 injections, and 4 (8%) received 3 injections. Fifty-seven percent of joints achieved contracture of 5° or less (29 of 51). Overall, 86% (43 of 50) patients had a 20° or greater increase in range of motion. The adverse event profile was consistent with previous studies. One ligament injury was reported. At a short-term follow-up of 1 year, recurrent contracture in joints previously successfully treated with CCH may be effectively retreated with up to 3 injections of CCH. Therapeutic IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Furtado, Rita Nely Vilar; Machado, Flávia Soares; Luz, Karine Rodrigues da; Santos, Marla Francisca Dos; Konai, Monique Sayuri; Lopes, Roberta Vilela; Natour, Jamil
To evaluate local joint variables after intra-articular injection with triamcinolone hexacetonide in rheumatoid arthritis patients. We blindly and prospectively (baseline, 1, 4, 12 and 24 weeks) evaluated metacarpophalangeal, wrist, elbow, shoulder, knee and ankle joints after triamcinolone hexacetonide intra-articular injection by the following outcome measures: visual analogue scale 0-10cm (VAS) for rest pain (VASR); VAS for movement pain (VASM); VAS for joint swelling (VASSw); flexion (FlexG) and extension (ExtG). 289 patients (635 joints) were studied. VASSw (p<0.001) and VASR (0.001
Cavalcanti, Samantha Cristine Santos X B; Corrêa, Luciana; Mello, Suzana Beatriz Veríssimo; Luz, João Gualberto C
2014-10-01
Methotrexate (MTX) is an anti-metabolite used in rheumatology and oncology. High doses are indicated for oncological treatment, whereas low doses are indicated for chronic inflammatory diseases. This study evaluated the effect of two MTX treatment schedules on the bone healing of the temporomandibular joint fracture in rats. Seventy-five adult male Wistar rats were used to generate an experimental unilateral medially rotated condylar fracture model that allows an evaluation of bone healing and the articular structures. The animals were subdivided into three groups that each received one of the following treatments intraperitoneally: saline (1 mL/week), low-dose MTX (3 mg/kg/week) and high-dose MTX (30 mg/kg). The histological study comprised fracture site and temporomandibular joint evaluations and bone neoformation was evaluated by histomorphometric analysis. A biochemical parameter of bone formation was also assessed. When compared with saline, high-dose MTX delayed bone fracture repairs. In this latter group, after 90 days, the histological analysis revealed atrophy of the fibrocartilage and the presence of fibrous tissue in the joint space. The histomorphometric analysis revealed diminished bone neoformation. The alkaline phosphatase levels also decreased after MTX treatment. It was concluded that high-dose MTX impaired mandibular condyle repair and induced degenerative articular changes. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Joint probability of statistical success of multiple phase III trials.
Zhang, Jianliang; Zhang, Jenny J
2013-01-01
In drug development, after completion of phase II proof-of-concept trials, the sponsor needs to make a go/no-go decision to start expensive phase III trials. The probability of statistical success (PoSS) of the phase III trials based on data from earlier studies is an important factor in that decision-making process. Instead of statistical power, the predictive power of a phase III trial, which takes into account the uncertainty in the estimation of treatment effect from earlier studies, has been proposed to evaluate the PoSS of a single trial. However, regulatory authorities generally require statistical significance in two (or more) trials for marketing licensure. We show that the predictive statistics of two future trials are statistically correlated through use of the common observed data from earlier studies. Thus, the joint predictive power should not be evaluated as a simplistic product of the predictive powers of the individual trials. We develop the relevant formulae for the appropriate evaluation of the joint predictive power and provide numerical examples. Our methodology is further extended to the more complex phase III development scenario comprising more than two (K > 2) trials, that is, the evaluation of the PoSS of at least k₀ (k₀≤ K) trials from a program of K total trials. Copyright © 2013 John Wiley & Sons, Ltd.
ERIC Educational Resources Information Center
Morris, Michael
2004-01-01
All evaluators face the challenge of striving to adhere to the highest possible standards of ethical conduct. Translating the AEA's Guiding Principles and the Joint Committee's Program Evaluation Standards into everyday practice, however, can be a complex, uncertain, and frustrating endeavor. Moreover, acting in an ethical fashion can require…
Evaluation of precast patches on U.S. 60 near the New Kent and James City County line.
DOT National Transportation Integrated Search
2006-01-01
This project evaluated the use of precast concrete patches for repairing jointed concrete pavement. Six patches were placed: three had dowels cast into them during fabrication, and three had dowels inserted in place (dowel bar retrofit). Fabrication ...
Audenaert, E A; Vigneron, L; Van Hoof, T; D'Herde, K; van Maele, G; Oosterlinck, D; Pattyn, C
2011-12-01
There is growing evidence that femoroacetabular impingement (FAI) is a probable risk factor for the development of early osteoarthritis in the nondysplastic hip. As FAI arises with end range of motion activities, measurement errors related to skin movement might be higher than anticipated when using previously reported methods for kinematic evaluation of the hip. We performed an in vitro validation and reliability study of a noninvasive method to define pelvic and femur positions in end range of motion activities of the hip using an electromagnetic tracking device. Motion data, collected from sensors attached to the bone and skin of 11 cadaver hips, were simultaneously obtained and compared in a global reference frame. Motion data were then transposed in the hip joint local coordinate systems. Observer-related variability in locating the anatomical landmarks required to define the local coordinate system and variability of determining the hip joint center was evaluated. Angular root mean square (RMS) differences between the bony and skin sensors averaged 3.2° (SD 3.5°) and 1.8° (SD 2.3°) in the global reference frame for the femur and pelvic sensors, respectively. Angular RMS differences between the bony and skin sensors in the hip joint local coordinate systems ranged at end range of motion and dependent on the motion under investigation from 1.91 to 5.81°. The presented protocol for evaluation of hip motion seems to be suited for the 3-D description of motion relevant to the experimental and clinical evaluation of femoroacetabular impingement.
Joint Sequence Analysis: Association and Clustering
ERIC Educational Resources Information Center
Piccarreta, Raffaella
2017-01-01
In its standard formulation, sequence analysis aims at finding typical patterns in a set of life courses represented as sequences. Recently, some proposals have been introduced to jointly analyze sequences defined on different domains (e.g., work career, partnership, and parental histories). We introduce measures to evaluate whether a set of…
School District-University Cooperation in Competency-Based Inservice Teacher Education.
ERIC Educational Resources Information Center
Grunewald, Robert N.
This article describes a jointly planned and jointly evaluated course offered through Washington State University General Extension. The purpose of the course was to improve instruction in elementary classrooms through use of competency-based training materials (Minicourses) from the Far West Laboratory for Educational Research and Development.…
Tseng, Chin-Hsiao; Tseng, Ching-Ping; Chong, Choon-Khim
2010-05-01
We investigated the individual and joint effects of hypertension, smoking, dyslipidemia, and obesity and angiotensin-converting enzyme (ACE) DD genotype on albuminuria in Taiwanese type 2 diabetic patients. ACE genotypes were determined in 519 (287 men and 232 women) patients aged 58.5 (SD: 9.0) years. Among them, 240 had albuminuria (urinary albumin-to-creatinine ratio > or =30 microg/mg). Logistic regression was used to evaluate the individual and joint effects of risk factors and DD classified by two-by-four table. The adjusted odds ratios were significant for hypertension, smoking and obesity but not for DD and dyslipidemia in models evaluating individual effects. However, while analyzing the joint effects of DD and hypertension, smoking, dyslipidemia and obesity, the respective adjusted odds ratios were 3.253 (1.261-8.391), 3.016 (1.086-8.376), 2.385 (1.010-5.630) and 2.508 (1.117-5.631). Hypertension, smoking, dyslipidemia and obesity jointly play an important role with DD genotype in mediating albuminuria. 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Design and Evaluation of a Bolted Joint for a Discrete Carbon-Epoxy Rod-Reinforced Hat Section
NASA Technical Reports Server (NTRS)
Baker, Donald J.; Rousseau, Carl Q.
1996-01-01
The use of pre-fabricated pultruded carbon-epoxy rods has reduced the manufacturing complexity and costs of stiffened composite panels while increasing the damage tolerance of the panels. However, repairability of these highly efficient discrete stiffeners has been a concern. Design, analysis, and test results are presented in this paper for a bolted-joint repair for the pultruded rod concept that is capable of efficiently transferring axial loads in a hat-section stiffener on the upper skin segment of a heavily loaded aircraft wing component. A tension and a compression joint design were evaluated. The tension joint design achieved approximately 1.0 percent strain in the carbon-epoxy rod-reinforced hat-section and failed in a metal fitting at 166 percent of the design ultimate load. The compression joint design failed in the carbon-epoxy rod-reinforced hat-section test specimen area at approximately 0.7 percent strain and at 110 percent of the design ultimate load. This strain level of 0.7 percent in compression is similar to the failure strain observed in previously reported carbon-epoxy rod-reinforced hat-section column tests.
Joint modelling of annual maximum drought severity and corresponding duration
NASA Astrophysics Data System (ADS)
Tosunoglu, Fatih; Kisi, Ozgur
2016-12-01
In recent years, the joint distribution properties of drought characteristics (e.g. severity, duration and intensity) have been widely evaluated using copulas. However, history of copulas in modelling drought characteristics obtained from streamflow data is still short, especially in semi-arid regions, such as Turkey. In this study, unlike previous studies, drought events are characterized by annual maximum severity (AMS) and corresponding duration (CD) which are extracted from daily streamflow of the seven gauge stations located in Çoruh Basin, Turkey. On evaluation of the various univariate distributions, the Exponential, Weibull and Logistic distributions are identified as marginal distributions for the AMS and CD series. Archimedean copulas, namely Ali-Mikhail-Haq, Clayton, Frank and Gumbel-Hougaard, are then employed to model joint distribution of the AMS and CD series. With respect to the Anderson Darling and Cramér-von Mises statistical tests and the tail dependence assessment, Gumbel-Hougaard copula is identified as the most suitable model for joint modelling of the AMS and CD series at each station. Furthermore, the developed Gumbel-Hougaard copulas are used to derive the conditional and joint return periods of the AMS and CD series which can be useful for designing and management of reservoirs in the basin.
Simpson, Brad G; Simon, Corey B
2014-01-01
A 40-year old female presented to physical therapy with a one-year history of insidious right anteromedial and anterolateral knee pain. Additionally, the patient had a history of multiple lateral ankle sprains bilaterally, the last sprain occurring on the right ankle 1 year prior to the onset of knee pain. The patient was evaluated and given a physical therapy diagnosis of patellofemoral pain syndrome (PFPS), with associated talocrural and tibiofemoral joint hypomobility limiting ankle dorsiflexion and knee extension, respectively. Treatment included a high-velocity low amplitude thrust manipulation to the talocrural joint, which helped restore normal ankle dorsiflexion range of motion. The patient also received tibiofemoral joint non-thrust manual therapy to regain normal knee extension mobility prior to implementing further functional progression exercises to her home program (HEP). This case report highlights the importance of a detailed evaluation of knee and ankle joint mobility in patients presenting with anterior knee pain. Further, manual physical therapy to the lower extremity was found to be successful in restoring normal movement patterns and pain-free function in a patient with chronic anterior knee pain. PMID:24976753
Hammond, A; Lincoln, N; Sutcliffe, L
1999-05-01
Joint protection (JP) is a self-management technique widely taught to people with rheumatoid arthritis (RA). JP education aims to enable people with RA to reduce pain, inflammation, joint stress and reduce risks of deformity through using assistive devices and alternative movement patterns of affected joints to perform everyday activities. Previous studies evaluating JP education methods common in the UK have identified JP adherence is poor. A group education programme was developed using the Health Belief Model and Self-efficacy Theory. Strategies used to maximise JP adherence included goal-setting, contracting, modelling, homework programmes, motor learning theory, recall enhancing methods and mental practice. A crossover trial (n = 35) was conducted. Adherence with JP was measured using an objective observational test (the Joint Protection Behaviour Assessment). Significant improvements in use of JP were recorded at 12 and 24 weeks post-education (P < 0.01). No significant changes in measures of pain, functional disability, grip strength, self-efficacy or helplessness occurred post-education, although this may have been due to the small sample size recruited. In conclusion, JP adherence can be facilitated through the use of educational-behavioural strategies, suggesting this approach should be more widely adopted in clinical practice.
Interventions for treating osteoarthritis of the big toe joint.
Zammit, Gerard V; Menz, Hylton B; Munteanu, Shannon E; Landorf, Karl B; Gilheany, Mark F
2010-09-08
Osteoarthritis affecting of the big toe joint of the foot (hallux limitus or rigidus) is a common and painful condition. Although several treatments have been proposed, few have been adequately evaluated. To identify controlled trials evaluating interventions for osteoarthritis of the big toe joint and to determine the optimum intervention(s). Literature searches were conducted across the following electronic databases: CENTRAL; MEDLINE; EMBASE; CINAHL; and PEDro (to 14th January 2010). No language restrictions were applied. Randomised controlled trials, quasi-randomised trials, or controlled clinical trials that assessed treatment outcomes for osteoarthritis of the big toe joint. Participants of any age or gender with osteoarthritis of the big toe joint (defined either radiographically or clinically) were included. Two authors examined the list of titles and abstracts identified by the literature searches. One content area expert and one methodologist independently applied the pre-determined inclusion and exclusion criteria to the full text of identified trials. To minimise error and reduce potential bias, data were extracted independently by two content experts. Only one trial satisfactorily fulfilled the inclusion criteria and was included in this review. This trial evaluated the effectiveness of two physical therapy programs in 20 individuals with osteoarthritis of the big toe joint. Assessment outcomes included pain levels, big toe joint range of motion and plantar flexion strength of the hallux. Mean differences at four weeks follow up were 3.80 points (95% CI 2.74 to 4.86) for self reported pain, 28.30 degrees (95% CI 21.37 to 35.23) for big toe joint range of motion, and 2.80 kg (95% CI 2.13 to 3.47) for muscle strength. Although differences in outcomes between treatment and control groups were reported, the risk of bias was high. The trial failed to employ appropriate randomisation or adequate allocation concealment, used a relatively small sample and incorporated a short follow up (four weeks). No adverse reactions were reported. The reviewed trial presented a high risk of bias, which limited conclusions that could be drawn from the presented data. The inclusion of only one trial indicates the need for more robust randomised controlled trials to determine the efficacy of interventions for this condition.
A novel hybrid joining methodology for composite to steel joints
NASA Astrophysics Data System (ADS)
Sarh, Bastian
This research has established a novel approach for designing, analyzing, and fabricating load bearing structural connections between resin infused composite materials and components made of steel or other metals or alloys. A design philosophy is proposed wherein overlapping joint sections comprised of fiber reinforced plastics (FRP's) and steel members are connected via a combination of adhesive bonding and integrally placed composite pins. A film adhesive is utilized, placed into the dry stack prior to resin infusion and is cured after infusion through either local heat elements or by placing the structure into an oven. The novel manner in which the composite pins are introduced consists of perforating the steel member with holes and placing pre-formed composite pins through them, also prior to resin infusion of the composite section. In this manner joints are co-molded structures such that secondary processing is eliminated. It is shown that such joints blend the structural benefits of adhesive and mechanically connected joints, and that the fabrication process is feasible for low-cost, large-scale production as applicable to the shipbuilding industry. Analysis procedures used for designing such joints are presented consisting of an adhesive joint design theory and a pin placement theory. These analysis tools are used in the design of specimens, specific designs are fabricated, and these evaluated through structural tests. Structural tests include quasi-static loading and low cycle fatigue evaluation. This research has thereby invented a novel philosophy on joints, created the manufacturing technique for fabricating such joints, established simple to apply analysis procedures used in the design of such joints (consisting of both an adhesive and a pin placement analysis), and has validated the methodology through specimen fabrication and testing.
Adams, Stephen B; Moore, George E; Elrashidy, Mohammed; Mohamed, Ahmed; Snyder, Paul W
2010-08-01
To assess joint contamination with tissue and hair after arthrocentesis of equine fetlock joints. Experimental. Limb specimens from 8 equine cadavers. Soft tissues including the joint capsule were harvested from the dorsal aspect of the fetlock joints and mounted on a wooden frame. Needles inserted through the joint tissue preparation were flushed into tissue culture plates that were examined for tissue and hair debris. Variables evaluated were gauge and type of needle (16, 18, 20, and 22 G sharp disposable needles and 20 G disposable spinal needles with stylet), number of times each needle was used (1, 2, 3, 4), length of hair (unclipped, clipped, shaved with razor), and needle insertion speed (fast, slow). Descriptive and statistical evaluations were performed. Tissue contamination was identified in 1145 of 1260 wells and hair contamination was identified in 384 of 1260 wells. Twenty gauge needles inserted through unclipped hair resulted in the least amount of hair contamination. Compared with 20 G needles with fast insertion 1 time through unclipped hair the odds ratios for contamination with hair were significantly greater for 16 G sharp disposable needles, 20 G spinal needles, clipped hair, shaved hair, and reuse of the needles. Spinal needles inserted through unclipped hair transferred many long hairs into the joint space. Reuse of needles for arthrocentesis should be avoided. Removal of hair is not indicated for arthrocentesis with sharp injection needles but is recommended when using spinal needles with stylets. Joint contamination with hair and tissue debris will be decreased by specific needle insertion techniques. Decreased contamination of joints may reduce the frequency of joint infections after arthrocentesis.
NASA Technical Reports Server (NTRS)
Farrokh, Babak; Segal, Kenneth N.; Akkerman, Michael; Glenn, Ronald L.; Rodini, Benjamin T.; Fan, Wei-Ming; Kellas, Sortiris; Pineda, Evan J.
2014-01-01
In this work, an all-bonded out-of-autoclave (OoA) curved longitudinal composite joint concept, intended for use in the next generation of composite heavy lift launch vehicles, was evaluated and verified through finite element (FE) analysis, fabrication, testing, and post-test inspection. The joint was used to connect two curved, segmented, honeycomb sandwich panels representative of a Space Launch System (SLS) fairing design. The overall size of the resultant panel was 1.37 m by 0.74 m (54 in by 29 in), of which the joint comprised a 10.2 cm (4 in) wide longitudinal strip at the center. NASTRAN and ABAQUS were used to perform linear and non-linear analyses of the buckling and strength performance of the jointed panel. Geometric non-uniformities (i.e., surface contour imperfections) were measured and incorporated into the FE model and analysis. In addition, a sensitivity study of the specimens end condition showed that bonding face-sheet doublers to the panel's end, coupled with some stress relief features at corner-edges, can significantly reduce the stress concentrations near the load application points. Ultimately, the jointed panel was subjected to a compressive load. Load application was interrupted at the onset of buckling (at 356 kN 80 kips). A post-test non-destructive evaluation (NDE) showed that, as designed, buckling occurred without introducing any damage into the panel or the joint. The jointed panel was further capable of tolerating an impact damage to the same buckling load with no evidence of damage propagation. The OoA cured all-composite joint shows promise as a low mass factory joint for segmented barrels.
Oldenburg, J; Zimmermann, R; Katsarou, O; Theodossiades, G; Zanon, E; Niemann, B; Kellermann, E; Lundin, B
2015-01-01
In patients with haemophilia A, factor VIII (FVIII) prophylaxis reduces bleeding frequency and joint damage compared with on-demand therapy. To assess the effect of prophylaxis initiation age, magnetic resonance imaging (MRI) was used to evaluate bone and cartilage damage in patients with severe haemophilia A. In this cross-sectional, multinational investigation, patients aged 12–35 years were assigned to 1 of 5 groups: primary prophylaxis started at age <2 years (group 1); secondary prophylaxis started at age 2 to <6 years (group 2), 6 to <12 years (group 3), or 12−18 years (group 4); or on-demand treatment (group 5). Joint status at ankles and knees was assessed using Compatible Additive MRI scoring (maximum and mean ankle; maximum and mean of all 4 joints) and Gilbert scores in the per-protocol population (n = 118). All prophylaxis groups had better MRI joint scores than the on-demand group. MRI scores generally increased with current patient age and later start of prophylaxis. Ankles were the most affected joints. In group 1 patients currently aged 27−35 years, the median of maximum ankle scores was 0.0; corresponding values in groups 4 and 5 were 17.0 and 18.0, respectively [medians of mean index joint scores: 0.0 (group 1), 8.1 (group 2) and 13.8 (group 4)]. Gilbert scores revealed outcomes less pronounced than MRI scores. MRI scores identified pathologic joint status with high sensitivity. Prophylaxis groups had lower annualized joint bleeds and MRI scores vs. the on-demand group. Primary prophylaxis demonstrated protective effects against joint deterioration compared with secondary prophylaxis. PMID:25470205
Pest, Michael A.; Russell, Bailey A.; Zhang, Yu-Wen; Jeong, Jae-Wook; Beier, Frank
2017-01-01
Objective Mitogen-inducible gene 6 (MIG-6) regulates epidermal growth factor receptor (EGFR) signaling in synovial joint tissues. Whole-body knockout of the Mig6 gene in mice has been shown to induce osteoarthritis and joint degeneration. To evaluate the role of chondrocytes in this process, Mig6 was conditionally deleted from Col2a1-expressing cell types in the cartilage of mice. Methods Bone and cartilage in the synovial joints of cartilage-specific Mig6-deleted (knockout [KO]) mice and control littermates were compared. Histologic staining and immunohistochemical analyses were used to evaluate joint pathology as well as the expression of key extracellular matrix and regulatory proteins. Calcified tissue in synovial joints was assessed by micro–computed tomography (micro-CT) and whole-skeleton staining. Results Formation of long bones was found to be normal in KO animals. Cartilage thickness and proteoglycan staining of articular cartilage in the knee joints of 12-week-old KO mice were increased as compared to controls, with higher cellularity throughout the tissue. Radiopaque chondro-osseous nodules appeared in the knees of KO animals by 12 weeks of age and progressed to calcified bone–like tissue by 36 weeks of age. Nodules were also observed in the spine of 36-week-old animals. Erosion of bone at ligament entheses was evident by 12 weeks of age, by both histologic and micro-CT assessment. Conclusion MIG-6 expression in chondrocytes is important for the maintenance of cartilage and joint homeostasis. Dysregulation of EGFR signaling in chondrocytes results in anabolic activity in cartilage, but erosion of ligament entheses and the formation of ectopic chondro-osseous nodules severely disturb joint physiology. PMID:24966136
Evidence of cartilage repair by joint distraction in a canine model of osteoarthritis.
Wiegant, Karen; Intema, Femke; van Roermund, Peter M; Barten-van Rijbroek, Angelique D; Doornebal, Arie; Hazewinkel, Herman A W; Lafeber, Floris P J G; Mastbergen, Simon C
2015-02-01
Knee osteoarthritis (OA) is a degenerative joint disorder characterized by cartilage, bone, and synovial tissue changes that lead to pain and functional impairment. Joint distraction is a treatment that provides long-term improvement in pain and function accompanied by cartilage repair, as evaluated indirectly by imaging studies and measurement of biochemical markers. The purpose of this study was to evaluate cartilage tissue repair directly by histologic and biochemical assessments after joint distraction treatment. In 27 dogs, OA was induced in the right knee joint (groove model; surgical damage to the femoral cartilage). After 10 weeks of OA development, the animals were randomized to 1 of 3 groups. Two groups were fitted with an external fixator, which they wore for a subsequent 10 weeks (one group with and one without joint distraction), and the third group had no external fixation (OA control group). Pain/function was studied by force plate analysis. Cartilage integrity and chondrocyte activity of the surgically untouched tibial plateaus were analyzed 25 weeks after removal of the fixator. Changes in force plate analysis values between the different treatment groups were not conclusive. Features of OA were present in the OA control group, in contrast to the generally less severe damage after joint distraction. Those treated with joint distraction had lower macroscopic and histologic damage scores, higher proteoglycan content, better retention of newly formed proteoglycans, and less collagen damage. In the fixator group without distraction, similarly diminished joint damage was found, although it was less pronounced. Joint distraction as a treatment of experimentally induced OA results in cartilage repair activity, which corroborates the structural observations of cartilage repair indicated by surrogate markers in humans. Copyright © 2015 by the American College of Rheumatology.
ERIC Educational Resources Information Center
San Francisco State Coll., CA. Center for Technological Education.
The presentation, review and evaluation of innovative vocational-technical curriculums in operation was the major function of a San Francisco conference sponsored jointly by the Center for Technical Education at San Francisco State College and the Center for Studies in Vocational and Technical Education at the University of Wisconsin. Major…
Munhoz, Wagner Cesar; Marques, Amélia Pasqual; Siqueira, José Tadeu Tesseroli de
2004-01-01
Although the etiopathophysiology of internal temporomandibular joint internal disorders (TMJ ID) is still unknown, it has been suggested that head and body posture could be related to its initial onset, development and perpetuation. The purpose of the present study was to observe the relationship between cervical spine X-ray abnormalities and TMJ ID. This investigation evaluated 30 subjects with internal TMJ disorder symptoms (test group) and 20 healthy subjects (control group). Subjects were submitted to clinical and radiographic evaluation. Clinical evaluation comprised anamnesis and stomatognathic system physical examination. Radiographic evaluation comprised analysis of lateral cervical spine X-rays by three physical therapists and tracing on the same images. The test group presented twice as much cervical spine hyperlordosis as the control group (20.7% versus 10.5%), but almost half of rectification prevalence (41.4 versus 79.0%, p = 0.03). After that, the test group was divided into three subgroups according to TMJ dysfunction severity, evaluated by Helkimo's index. These subgroups were not significantly different, but the subgroup with more severe TMD showed a tendency to cervical spine hyperlordosis prevalence. Results showed a tendency for subjects with more severe TMD to exhibit cervical spine hyperlordosis. Nevertheless, studies with a larger number of subjects suffering from severe TMD are encouraged in order to corroborate the present findings.
Knee extensor dynamics in the volleyball approach jump: the influence of patellar tendinopathy.
Sorenson, Shawn C; Arya, Shruti; Souza, Richard B; Pollard, Christine D; Salem, George J; Kulig, Kornelia
2010-09-01
Controlled laboratory study using a cross-sectional design. To evaluate knee joint dynamics in elite volleyball players with and without a history of patellar tendinopathy, focusing on mechanical energy absorption and generation. We hypothesized that tendinopathy would be associated withreduced net joint work and net joint power. Patellar tendinopathy is a common, debilitating injury affecting competitive volleyball players. Thirteen elite male players with and without a history of patellar tendinopathy (mean ± SD age, 27 ± 7 years) performed maximum-effort volleyball approach jumps. Sagittal plane knee joint kinematics, kinetics, and energetics were quantified in the lead limb, using data obtained from a force platform and an 8-camera motion analysis system. Vertical ground reaction forces and pelvis vertical velocity at takeoff were examined. Independent sample t tests were used to evaluate group differences (α = .05). The tendinopathy group, compared to controls, demonstrated significant reductions (approximately 30%) in net joint work and net joint power during the eccentric phase of the jump, with no differences in the concentric phase. Positive to-negative net joint work and net joint power ratios were significantly higher in the tendinopathy group, which had a net joint work ratio of 1.00 (95% CI: 0.77, 1.24) versus 0.76 (95% CI: 0.64, 0.88) for controls, and a net joint power ratio of 1.62 (95% CI: 1.15, 2.10) versus 1.00 (95% CI: 0.80, 1.21) for controls. There were no significant differences in net joint moment, angular velocity, or range of motion. Peak vertical ground reaction forces were lower for the tendinopathy group, while average vertical ground reaction forces and pelvis vertical velocity were similar. Patellar tendinopathy is associated with differences in sagittal plane mechanical energy absorption at the knee during maximum-effort volleyball approach jumps. Net joint work and net joint power may help define underlying mechanisms, adaptive effects, or rehabilitative strategies for individuals with patellar tendinopathy.
A photoacoustic tomography and ultrasound combined system for proximal interphalangeal joint imaging
NASA Astrophysics Data System (ADS)
Xu, Guan; Rajian, Justin R.; Girish, Gandikota; Wang, Xueding
2013-03-01
A photoacoustic (PA) and ultrasound (US) dual modality system for imaging human peripheral joints is introduced. The system utilizes a commercial US unit for both US control imaging and PA signal acquisition. Preliminary in vivo evaluation of the system on normal volunteers revealed that this system can recover both the structural and functional information of intra- and extra-articular tissues. Presenting both morphological and pathological information in joint, this system holds promise for diagnosis and characterization of inflammatory joint diseases such as rheumatoid arthritis.
DOT National Transportation Integrated Search
2007-11-13
This document presents the findings from the baseline phase of the evaluation of the process being used by eight sites to develop a design for a Travel Management Coordination Center (TMCC) for improved coordination of human service transportation wi...
DOT National Transportation Integrated Search
1991-06-01
This report documents the construction, initial evaluation and final evaluation of several experimental features which were incorporated as part of an overlay of an existing PCC pavement in order to determine the feasibility of extending the asphalti...
An Evaluation of a Clerkship In Cardiology
ERIC Educational Resources Information Center
Edson, John N.; and others
1969-01-01
Evaluation of the clinical clerkship in Cardiology for general practitioners proves there is an urgent need for continuing post graduate medical education for general practitioners. Clerkship was offered jointly by the Long Island College Hospital and the State University of New York Downstate Medical Center, Brooklyn, New York. (IR)
This paper presents an EPA evaluation of the first field demonstration of an in situ stabilization/solidification process for contaminated soil under the EPA Superfund Innovative Technology Evaluation (SITE) program. Demonstration of this process was a joint effort of two vendors...
Control of large flexible space structures
NASA Technical Reports Server (NTRS)
Vandervelde, W. E.
1986-01-01
Progress in robust design of generalized parity relations, design of failure sensitive observers using the geometric system theory of Wonham, computational techniques for evaluation of the performance of control systems with fault tolerance and redundancy management features, and the design and evaluation od control systems for structures having nonlinear joints are described.
Report on the Audit of the Joint Civilian Orientation Conference Fund
1991-01-31
This is our final report on the audit of the Joint Civilian Orientation Conference (JCOC) Fund (the Fund). We performed the audit from June to July...1990. The Director, Budget and Finance, Washington Headquarters Services, requested the audit because a new Treasurer had been appointed. The overall...Instruction No. 48, Joint Civilian Orientation Conference Fund, May 31, 1983, and with DoD policy and guidelines. In addition, the audit evaluated
Interagency Evaluation of the Section 1206 Global Train and Equip Program
2009-08-31
Capabilities, Joint Staff, U.S. Africa Command, U.S. Central Command, U.S Joint Forces Command, U.S. Pacific Command, U.S. Southern Command, U.S. Special...Intensity Conflict & Interdependent Capabilities; Commanders of U.S. Africa Command, U.S. Central Command, U.S. Joint Forces Command, U.S. Pacific... Central Command, commented that coordinating the Section 1206 project proposal with the partner nation prior to submission would inflate the
NASA Technical Reports Server (NTRS)
Gyorgak, C. A.
1975-01-01
An evaluation was made of five braze filler metals for joining an aluminum-containing oxide dispersion-strengthened (ODS) alloy, TD-NiCrAl. All five braze filler metals evaluated are considered suitable for joining TD-NiCrAl in terms of wettability and flow. Also, the braze alloys appear to be tolerant of slight variations in brazing procedures since joints prepared by three sources using three of the braze filler metals exhibited similar brazing characteristics and essentially equivalent 1100 C stress-rupture properties in a brazed butt-joint configuration. Recommendations are provided for brazing the aluminum-containing ODS alloys.
Chen, H; Hu, X; Yang, G; Xiang, M
2017-04-01
Minimal invasive plate osteosynthesis (MIPO) is one of the most important techniques in the treatment for humeral shaft fractures. This study was performed to evaluate the efficacy of MIPO technique for the treatment for humeral shaft fractures. We retrospectively evaluated 128 cases with humeral shaft fractures that were treated with MIPO technique from March 2005 to August 2008. All the patients were followed up by routine radiological imaging and clinical examinations. Constant-Murley score and HSS elbow joint score were used to evaluate the treatment outcome. The average duration of the surgery was 60 min (range 40-95 min) without blood transfusion. All fractures healed without infection. All cases recovered carrying angle except four cases with 10°-15° cubitus varus. After the average follow-up of 23 (13-38) months, satisfactory function was achieved according to Constant-Murley score and HSS elbow joint score. Constant-Murley score was 80 on average (range 68-91). According to HSS elbow joint score, there were 123 cases of excellent clinical outcome and five cases of effective outcome. It seems to be a safe and effective method for managing humeral shaft fractures with MIPO technique.
Park, Jung Ho; Kim, Hee-Chun; Lee, Jae Hoon; Kim, Jin Soo; Roh, Si Young; Yi, Cheol Ho; Kang, Yoon Kyoo; Kwon, Bum Sun
2009-05-01
While the lower extremities support the weight and move the body, the upper extremities are essential for the activities of daily living, which require many detailed movements. Therefore, a disability of the upper extremity function should include a limitation of all motions of the joints and sensory loss, which affects the activities. In this study, disabilities of the upper extremities were evaluated according to the following conditions: 1) amputation, 2) joint contracture, 3) diseases of upper extremity, 4) weakness, 5) sensory loss of the finger tips, and 6) vascular and lymphatic diseases. The order of 1) to 6) is the order of major disability and there is no need to evaluate a lower order disability when a higher order one exists in the same joint or a part of the upper extremity. However, some disabilities can be either added or substituted when there are special contributions from multiple disabilities. An upper extremity disability should be evaluated after the completion of treatment and full adaptation when further functional changes are not expected. The dominance of the right or left hand before the disability should not be considered when there is a higher rate of disability.
Use of Terrestrial Laser Scanner for Rigid Airport Pavement Management.
Barbarella, Maurizio; D'Amico, Fabrizio; De Blasiis, Maria Rosaria; Di Benedetto, Alessandro; Fiani, Margherita
2017-12-26
The evaluation of the structural efficiency of airport infrastructures is a complex task. Faulting is one of the most important indicators of rigid pavement performance. The aim of our study is to provide a new method for faulting detection and computation on jointed concrete pavements. Nowadays, the assessment of faulting is performed with the use of laborious and time-consuming measurements that strongly hinder aircraft traffic. We proposed a field procedure for Terrestrial Laser Scanner data acquisition and a computation flow chart in order to identify and quantify the fault size at each joint of apron slabs. The total point cloud has been used to compute the least square plane fitting those points. The best-fit plane for each slab has been computed too. The attitude of each slab plane with respect to both the adjacent ones and the apron reference plane has been determined by the normal vectors to the surfaces. Faulting has been evaluated as the difference in elevation between the slab planes along chosen sections. For a more accurate evaluation of the faulting value, we have then considered a few strips of data covering rectangular areas of different sizes across the joints. The accuracy of the estimated quantities has been computed too.
Paschos, Nikolaos K; Makris, Eleftherios A; Hu, Jerry C; Athanasiou, Kyriacos A
2014-10-01
The purposes of this study were to identify differences in the biomechanical and biochemical properties among the articulating surfaces of the ankle joint and to evaluate the functional and biological properties of engineered neocartilage generated using chondrocytes from different locations in the ankle joint. The properties of the different topographies within the ankle joint (tibial plafond, talar dome, and distal fibula) were evaluated in 28 specimens using 7 bovine ankles; the femoral condyle was used as a control. Chondrocytes from the same locations were used to form 28 neocartilage constructs by tissue engineering using an additional 7 bovine ankles. The functional properties of neocartilage were compared with native tissue values. Articular cartilage from the tibial plafond, distal fibula, talar dome, and femoral condyle exhibited Young modulus values of 4.8 ± 0.5 MPa, 3.9 ± 0.1 MPa, 1.7 ± 0.2 MPa, and 4.0 ± 0.5 MPa, respectively. The compressive properties of the corresponding tissues were 370 ± 22 kPa, 242 ± 18 kPa, 255 ± 26 kPa, and 274 ± 18 kPa, respectively. The tibial plafond exhibited 3-fold higher tensile properties and 2-fold higher compressive and shear moduli compared with its articulating talar dome; the same disparity was observed in neocartilage. Similar trends were detected in biochemical data for both native and engineered tissues. The cartilage properties of the various topographic locations within the ankle are significantly different. In particular, the opposing articulating surfaces of the ankle have significantly different biomechanical and biochemical properties. The disparity between tibial plafond and talar dome cartilage and chondrocytes warrants further evaluation in clinical studies to evaluate their exact role in the pathogenesis of ankle lesions. Therapeutic modalities for cartilage lesions need to consider the exact topographic source of the cells or cartilage grafts used. Furthermore, the capacity of generating neocartilage implants from location-specific chondrocytes of the ankle joint may be used in the future as a tool for the treatment of chondral lesions. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
A passive exoskeleton with artificial tendons: design and experimental evaluation.
van Dijk, Wietse; van der Kooij, Herman; Hekman, Edsko
2011-01-01
We developed a passive exoskeleton that was designed to minimize joint work during walking. The exoskeleton makes use of passive structures, called artificial tendons, acting in parallel with the leg. Artificial tendons are elastic elements that are able to store and redistribute energy over the human leg joints. The elastic characteristics of the tendons have been optimized to minimize the mechanical work of the human leg joints. In simulation the maximal reduction was 40 percent. The performance of the exoskeleton was evaluated in an experiment in which nine subjects participated. Energy expenditure and muscle activation were measured during three conditions: Normal walking, walking with the exoskeleton without artificial tendons, and walking with the exoskeleton with the artificial tendons. Normal walking was the most energy efficient. While walking with the exoskeleton, the artificial tendons only resulted in a negligibly small decrease in energy expenditure. © 2011 IEEE
Evaluation of Laser Braze-welded Dissimilar Al-Cu Joints
NASA Astrophysics Data System (ADS)
Schmalen, Pascal; Plapper, Peter
The thermal joining of Aluminum and Copper is a promising technology towards automotive battery manufacturing. The dissimilar metals Al-Cu are difficult to weld due to their different physicochemical characteristics and the formation of intermetallic compounds (IMC), which have reduced mechanical and electric properties. There is a critical thickness of the IMCs where the favored mechanical properties of the base material can be preserved. The laser braze welding principle uses a position and power oscillated laser-beam to reduce the energy input and the intermixture of both materials and therefore achieves minimized IMCs thickness. The evaluation of the weld seam is important to improve the joint performance and enhance the welding process. This paper is focused on the characterization and quantification of the IMCs. Mechanical, electrical and metallurgical methods are presented and performed on Al1050 and SF-Cu joints and precise weld criteria are developed.
Schwalbe, H J; Bamfaste, G; Franke, R P
1999-01-01
Quality control in orthopaedic diagnostics according to DIN EN ISO 9000ff requires methods of non-destructive process control, which do not harm the patient by radiation or by invasive examinations. To obtain an improvement in health economy, quality-controlled and non-destructive measurements have to be introduced into the diagnostics and therapy of human joints and bones. A non-invasive evaluation of the state of wear of human joints and of the cracking tendency of bones is, as of today's point of knowledge, not established. The analysis of acoustic emission signals allows the prediction of bone rupture far below the fracture load. The evaluation of dry and wet bone samples revealed that it is possible to conclude from crack initiation to the bone strength and thus to predict the probability of bone rupture.
Espin‐Garcia, Osvaldo; Craiu, Radu V.
2017-01-01
ABSTRACT We evaluate two‐phase designs to follow‐up findings from genome‐wide association study (GWAS) when the cost of regional sequencing in the entire cohort is prohibitive. We develop novel expectation‐maximization‐based inference under a semiparametric maximum likelihood formulation tailored for post‐GWAS inference. A GWAS‐SNP (where SNP is single nucleotide polymorphism) serves as a surrogate covariate in inferring association between a sequence variant and a normally distributed quantitative trait (QT). We assess test validity and quantify efficiency and power of joint QT‐SNP‐dependent sampling and analysis under alternative sample allocations by simulations. Joint allocation balanced on SNP genotype and extreme‐QT strata yields significant power improvements compared to marginal QT‐ or SNP‐based allocations. We illustrate the proposed method and evaluate the sensitivity of sample allocation to sampling variation using data from a sequencing study of systolic blood pressure. PMID:29239496
Cranial cruciate stability in the rottweiler and racing greyhound: an in vitro study.
Wingfield, C; Amis, A A; Stead, A C; Law, H T
2000-05-01
An in vitro biomechanical study of cadaver stifles from rottweilers and racing greyhounds was undertaken to evaluate the contribution of the cranial cruciate ligament to stifle joint stability. This was performed at differing stifle joint angles, first with the joint capsules and ligaments intact and then with all structures removed except for the cranial cruciate ligament. Craniocaudal laxity increased in both breeds as stifle flexion increased. The rottweiler stifle showed greater craniocaudal joint laxity than the racing greyhound at all joint angles between 150 degrees and 110 degrees, but the actual increases in joint laxity between these joint angles were similar for both breeds. Tibial rotation during craniocaudal loading of the stifle increased craniocaudal laxity in both breeds during joint flexion. The relative contribution of the cranial cruciate ligament to cranial stability of the stifle joint increased as the joint flexed and was similar in both breeds.
Wen, Chuan-Bing; Li, Yong-Zhong; Tang, Qin-Qin; Sun, Lin; Xiao, Hong; Yang, Bang-Xiang; Song, Li; Liu, Hui
2013-03-01
To investigate the feasibility, accuracy of B ultrasound in the examination of joint space of lumbar spine facet joints compared with CT scan. Ten healthy adult volunteers were enrolled. The joint space of lumbar facet joints was measured by ultrasound. To identify the spinal levels, the posterior parasagittal sonograms were obtained at levels L1 to S1. The lumbar facet joints were delineated with the help of transverse sonograms at each level. Meanwhile, the lumbar facet joints were evaluated by spiral CT on the same plane, reformatted to 1-mm axial slices. A total of 88 lumbar facet joints from L1 to S1 were clearly visualized in the 10 volunteers. Both ultrasound and CT measurements showed the same average depth and lateral distance of lumbar facet joint space (P > 0.05). The lumbar facet joint space can be accurately demonstrated by ultrasound.
Microstructure evolution in dissimilar AA6060/copper friction stir welded joints
NASA Astrophysics Data System (ADS)
Kalashnikova, T. A.; Shvedov, M. A.; Vasilyev, P. A.
2017-12-01
Friction stir welding process has been applied for making a dissimilar copper/aluminum alloy joint. The grain microstructure and mechanical properties of the obtained joint were studied. The structure of the cross-section of the FSW compound was analyzed. The microstructural evolution of the joint was examined using optical microscopy. The mechanical properties of the intermetallic particles were evaluated by measuring the microhardness according to the Vickers method. The microhardness of the intermetallic particles was by a factor of 4 lower than that of the particles obtained by fusion welding. The results of the investigations enable using friction stir welding for making dissimilar joints.
Shape Memory Polymers: A Joint Chemical and Materials Engineering Hands-On Experience
ERIC Educational Resources Information Center
Seif, Mujan; Beck, Matthew
2018-01-01
Hands-on experiences are excellent tools for increasing retention of first year engineering students. They also encourage interdisciplinary collaboration, a critical skill for modern engineers. In this paper, we describe and evaluate a joint Chemical and Materials Engineering hands-on lab that explores cross-linking and glass transition in…
47 CFR 53.213 - Audit analysis and evaluation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... auditor shall submit a draft of the audit report to the Federal/State joint audit team. (1) The Federal... auditor. Exceptions of the Federal/State joint audit team to the finding and conclusions of the independent auditor that remain unresolved shall be included in the final audit report. (2) Within 15 days...
Meta-analysis genomewide association of pork quality traits: ultimate pH and shear force
USDA-ARS?s Scientific Manuscript database
It is common practice to perform genome-wide association analysis (GWA) using a genomic evaluation model of a single population. Joint analysis of several populations is more difficult. An alternative to joint analysis could be the meta-analysis (MA) of several GWA from independent genomic evaluatio...
Nondestructive Evaluation of Adhesive Bond Quality: State of the Art Review
1989-06-01
conducted using a and Harnik (6) developed a quantitative medium-focused, 1/4-inch diameter, 10-MHz method of testing adhesive bonded joints transducer...Couchman." Spectral Analysis Tech- E. Harnik . "The Testing of Adhesive- nique of Ultrasonic NDT of Advanced Bonded Joints by a Very High Resolu
Lower Limbs Function and Pain Relationships after Unilateral Total Knee Arthroplasty
ERIC Educational Resources Information Center
Tali, Maie; Maaroos, Jaak
2010-01-01
The aim of the study was to evaluate gait characteristics, lower limbs joint function, and pain relationships associated with knee osteoarthritis of female patients before and 3 months after total knee arthroplasty at an outpatient clinic rehabilitation department. Gait parameters were registered, the active range of lower extremity joints was…
45 CFR 1355.35 - Program improvement plans.
Code of Federal Regulations, 2013 CFR
2013-10-01
... developed jointly by title IV-E agency and Federal staff in consultation with the review team; (ii) Identify... how the action steps in the plan build on and make progress over prior program improvement plans; (vii... evaluated jointly by the title IV-E agency and ACF, in collaboration with other members of the review team...
Evaluatie Constructie Joint Support Ship (Evaluation Structure Joint Support Ship)
2008-03-15
die de toegevoeade massa berekent volgens ONGERUBRICEERD -62- ONGERUBRICEERD I TNO-rapport 1 2008-D-R0437 dezelfde theorie als gebruikt binnen...I2008-D-RO437 -69 8 Ondertekening Auteur : Ir. T.N. Bosman Approved: Ir. J.E. van Aanhold C’ ’ Visa: Ir. W. Trouwborst ONGERUBRICEERD -70
ERIC Educational Resources Information Center
Lamborn, Susie D.; Felbab, Amanda J.
2003-01-01
Study evaluated both the parenting styles and family ecologies models with interview responses from African American adolescents. Analyses contrasted each model with a joint model for predicting self esteem, self reliance, work orientation, and ethnic identity. Overall, findings suggest that a joint model that combines elements from both models…
47 CFR 53.213 - Audit analysis and evaluation.
Code of Federal Regulations, 2011 CFR
2011-10-01
... auditor shall submit a draft of the audit report to the Federal/State joint audit team. (1) The Federal... auditor. Exceptions of the Federal/State joint audit team to the finding and conclusions of the independent auditor that remain unresolved shall be included in the final audit report. (2) Within 15 days...
Measuring Clearance Mechanics Based on Dynamic Leg Length
ERIC Educational Resources Information Center
Khamis, Sam; Danino, Barry; Hayek, Shlomo; Carmeli, Eli
2018-01-01
The aim of this study was to quantify clearance mechanics during gait. Seventeen children diagnosed with hemiplegic cerebral palsy underwent a three-dimensional gait analysis evaluation. Dynamic leg lengths were measured from the hip joint center to the heel, to the ankle joint center and to the forefoot throughout the gait cycle. Significant…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-24
... Production Act of 1993--Joint Venture Under Tip Award No. 70NANB10H014 To Perform Project Entitled: Automated... Project Entitled: Automated Nondestructive Evaluation and Rehabilitation System (``ANDERS'') for Bridge... approaches or fragmented NDE, (2) comprehensive condition and structural assessment (including the...
Evaluation of the marsh deer stifle joint by imaging studies and gross anatomy.
Shigue, D A; Rahal, S C; Schimming, B C; Santos, R R; Vulcano, L C; Linardi, J L; Teixeira, C R
2015-12-01
This study aimed to evaluate the stifle joint of marsh deer using imaging studies and in comparison with gross anatomy. Ten hindlimbs from 5 marsh deer (Blastocerus dichotomus) were used. Radiography, computed tomography (CT) and magnetic resonance imaging (MRI) were performed in each stifle joint. Two hindlimbs were dissected to describe stifle gross anatomy. The other limbs were sectioned in sagittal, dorsal or transverse planes. In the craniocaudal radiographic view, the lateral femoral condyle was broader than the medial femoral condyle. The femoral trochlea was asymmetrical. Subsequent multiplanar reconstruction revealed in the cranial view that the external surface of the patella was roughened, the medial trochlea ridge was larger than the lateral one, and the extensor fossa at the lateral condyle was next to the lateral ridge. The popliteal fossa was better visualized via the lateral view. Sagittal MRI images identified lateral and medial menisci, caudolateral and craniomedial bundles of cranial cruciate ligament, caudal cruciate ligament, patellar ligament and common extensor tendon. In conclusion, the marsh deer stifle presents some anatomical characteristics of the ovine stifle joint. © 2014 Blackwell Verlag GmbH.
NASA Technical Reports Server (NTRS)
Zanoni, Vicki; Ryan, Robert; Pagnutti, Mary; Baldridge, Braxton; Roylance, Spencer; Snyder, Greg; Lee, George; Stanley, Tom
2002-01-01
An overview of the Joint Agency Commercial Imagery Evalation (JACIE) team is presented. JACIE, composed of the National Aeronautics and Space Administration (NASA), the National Imagery and Mapping Agency (NIMA), and the U.S. Geological Survey (USGS), was formed to leverage government agencies' capabilities for the characterization of commercial remote sensing data. Each JACIE agency purchases, or plans to purchase, commercial imagery to support its research and applications. It is critical that the data be assessed for its accuracy and utility. Through JACIE, NASA, NIMA, and USGS jointly characterized image products from Space Imaging's IKONOS satellite. Each JACIE agency performed an aspect of the characterization based on its expertise. NASA and its university partners performed a system characterization focusing on radiometric calibration, geopositional accuracy, and spatial resolution assessment; NIMA performed image interpretability and feature extraction evaluations; and USGS assessed geopositional accuracy of several IKONOS products. The JACIE team purchased IKONOS imagery of several study sites to perform the assessments and presented results at an industry-government workshop. Future plans for JACIE include the characterization of DigitalGlobe's QuickBird-2 image products.
Design and preliminary evaluation of an exoskeleton for upper limb resistance training
NASA Astrophysics Data System (ADS)
Wu, Tzong-Ming; Chen, Dar-Zen
2012-06-01
Resistance training is a popular form of exercise recommended by national health organizations, such as the American College of Sports Medicine (ACSM) and the American Heart Association (AHA). This form of training is available for most populations. A compact design of upper limb exoskeleton mechanism for homebased resistance training using a spring-loaded upper limb exoskeleton with a three degree-of-freedom shoulder joint and a one degree-of-freedom elbow joint allows a patient or a healthy individual to move the upper limb with multiple joints in different planes. It can continuously increase the resistance by adjusting the spring length to train additional muscle groups and reduce the number of potential injuries to upper limb joints caused by the mass moment of inertia of the training equipment. The aim of this research is to perform a preliminary evaluation of the designed function by adopting an appropriate motion analysis system and experimental design to verify our prototype of the exoskeleton and determine the optimal configuration of the spring-loaded upper limb exoskeleton.
[The analysis of epidemiology, clinical symptoms, serological tests in the course of borreliosis].
Biesiada, Grazyna; Czepiel, Jacek; Leśniak, Maciej; Garlicki, Aleksander; Mach, Tomasz
2010-01-01
Lyme disease is an animal-borne disease, caused by spirochetes of the Borrelia burgdorferi (Bb). The infection is transmitted by ticks of the Ixodes ricinus species. Humans are infected through a tick bite to the skin. The aim of the study was evaluation of epidemiology, symptoms and serologic factors in Lyme disease. We have enrolled 39 patients from Malopołska region in the study treated for Lyme borreliosis. History of tick biting, clinical signs and symptoms and serological tests were evaluated. The most common symptoms were headaches and pain of the large joints. Patients with untreated erithema migrans (EM) more often developed symptoms from nervous system (83%) than joints (54%). We found abnormalities which confirmed inflammation in CSF in 24.3% of patients. Patients with positive IgG antibodies against Bb in CSF and confirmed their intrathecal synthesis had never had EM in the past. There is low percentage of the patients who were treated due to EM. Patients with untreated EM more often developed symptoms from nervous system than joints. The most common symptoms among our patients were headaches and pain of large joints.
El-Wakeel, Amr S; Mohammed, Nazmi A; Aly, Moustafa H
2016-09-10
In this work, a free space optical communication (FSO) link is proposed and utilized to explore and evaluate the FSO link performance under the joint occurrence of the atmospheric scattering and turbulence phenomena for 850 and 1550 nm operation. Diffraction and nondiffraction-limited systems are presented and evaluated for both wavelengths' operation, considering far-field conditions under different link distances. Bit error rate, pointing error angles, beam divergence angles, and link distance are the main performance indicators that are used to evaluate and compare the link performance under different system configurations and atmospheric phenomena combinations. A detailed study is performed to provide the merits of this work. For both far-field diffraction-limited and nondiffraction-limited systems, it is concluded that 1550 nm system operation is better than 850 nm for the whole presented joint occurrences of atmospheric scattering and turbulence.
Metzlaff, S; Rosslenbroich, S; Forkel, P H; Schliemann, B; Arshad, H; Raschke, M; Petersen, W
2016-06-01
This study was performed to compare the clinical results of a minimally invasive technique for acute acromioclavicular (AC) joint dislocation repair with the traditional hook plate fixation. Forty-four patients with an acute (within 2 weeks after trauma) complete AC joint separation (35 male, nine female; median age 36.2 years, range 18-56) underwent surgical repair with either a minimally invasive AC joint repair or a conventional hook plate. Functional outcome was evaluated using the Constant-Murley Score (CMS), the TAFT score and the AC joint instability score (ACJI). Radiographic evaluation was performed with bilateral anterior-posterior (a.p.) stress and Alexander views. All patients were available after a median follow-up of 32 months (range 24-51). There were no significant differences in the mean CMS, Taft score and the ACJI between the two groups. The radiological assessment revealed no significant difference in the coracoclavicular distance. In both groups, a slight loss of reduction was observed. Periarticular ossification was seen in 11 patients of the minimally invasive AC joint repair and eight patients of the hook plate group but this did not affect the final outcome. Hook plates were removed after a median interval of 11.9 weeks (range 10-13). Good clinical results can be achieved with both minimally invasive AC joint repair and hook plate fixation. However, in the hook plate group a second operation is mandatory for plate removal. III.
Use of vitamin B12 in joint lavage for determination of dilution factors of canine synovial fluid.
de Bruin, Tanya; de Rooster, Hilde; van Bree, Henri; Cox, Eric
2005-11-01
To test a modified saline (0.9% NaCl) solution joint washing (lavage) technique that includes the use of vitamin B12 as an internal marker for the evaluation of synovial fluid dilution in lavage samples from canine joints. 9 plasma samples obtained from blood samples of 9 healthy dogs and 9 synovial fluid samples aspirated from stifle joints of 9 cadaveric dogs. Photometric absorbances of 25% vitamin B12 solution, canine synovial fluid, and canine plasma were measured in a spectrophotometer to establish an optimal wavelength for analysis. Canine synovial fluid and plasma samples were mixed with the 25% vitamin B12 solution to obtain 1%, 3%, 5%, 10%, 20%, and 50% solutions of synovial fluid or plasma. Diluted synovial fluid and plasma samples were used to simulate joint lavage samples and to examine the possible interference of these substances (synovial fluid or plasma) with the absorbance of the 25% vitamin B12 solution in photometric analysis. The optimal wavelength was found to be at 550 nm. Canine synovial fluid and plasma samples did not interfere with the absorbance measurements of the 25% vitamin B12 solution up to a 50% dilution of plasma or synovial fluid. The modified saline solution joint lavage method with the use of a 25% vitamin B12 solution as an internal standard provides an accurate and reliable technique for the evaluation of synovial fluid dilution in lavage samples from canine joints.
Measurement of damping of graphite epoxy composite materials and structural joints
NASA Technical Reports Server (NTRS)
Crocker, Malcolm J.; Rao, Mohan D.; Raju, P. K.; Yan, Xinche
1989-01-01
The damping capacity of graphite epoxy materials and structural joints was evaluated. The damping ratio of different composite specimens and bonded joints were systematically evaluated under normal atmospheric conditions and in a vacuum environment. Free and forced vibration test methods were employed for measuring the damping ratios. The effect of edge support conditions on the damping value of a composite tube specimen was studied by using a series of experiments performed on the specimen with different edge supports. It was found that simulating a free-free boundary conditions by having no constraints at the ends gives the lowest value of the material damping of the composite. The accuracy of the estimation of the damping ratio value was improved by using a curve-fitting technique on the response data obtained through measurement. The effect of outgassing (moisture desorption) on the damping capacity was determined by measuring the damping ratio of the tube specimen in a vacuum environment before and after outgassing had occurred. The effects of high and low temperatures on the damping was also investigated by using a series of experiments on tube and beam specimens. An analytical model to study the vibrations of a bonded lap joint system was formulated. Numerical results were generated for different overlap ratios of the system. These were compared with experimental results. In order to determine the influence of bonded joints on the material damping capacity, experiments were conducted on bonded lap-jointed and double-butt-jointed specimens. These experimental results were compared with simple beam specimens with no joints.
Leijnse, J N A L; Quesada, P M; Spoor, C W
2010-08-26
The human finger contains tendon/ligament mechanisms essential for proper control. One mechanism couples the movements of the interphalangeal joints when the (unloaded) finger is flexed with active deep flexor. This study's aim was to accurately determine in a large finger sample the kinematics and variability of the coupled interphalangeal joint motions, for potential clinical and finger model validation applications. The data could also be applied to humanoid robotic hands. Sixty-eight fingers were measured in seventeen hands in nine subjects. Fingers exhibited great joint mobility variability, with passive proximal interphalangeal hyperextension ranging from zero to almost fifty degrees. Increased measurement accuracy was obtained by using marker frames to amplify finger segment motions. Gravitational forces on the marker frames were not found to invalidate measurements. The recorded interphalangeal joint trajectories were highly consistent, demonstrating the underlying coupling mechanism. The increased accuracy and large sample size allowed for evaluation of detailed trajectory variability, systematic differences between flexion and extension trajectories, and three trigger types, distinct from flexor tendon triggers, involving initial flexion deficits in either proximal or distal interphalangeal joint. The experimental methods, data and analysis should advance insight into normal and pathological finger biomechanics (e.g., swanneck deformities), and could help improve clinical differential diagnostics of trigger finger causes. The marker frame measuring method may be useful to quantify interphalangeal joints trajectories in surgical/rehabilitative outcome studies. The data as a whole provide the most comprehensive collection of interphalangeal joint trajectories for clinical reference and model validation known to us to date. 2010 Elsevier Ltd. All rights reserved.
Army Networks: Opportunities Exist to Better Utilize Results from Network Integration Evaluations
2013-08-01
monitor operations; a touch screen-based mission command planning tool; and an antenna mast . The Army will field only one of these systems in capability...Office JTRS Joint Tactical Radio System NIE Network Integration Evaluation OSD Office of the Secretary of Defense SUE System under Evaluation...command systems . A robust transport layer capable of delivering voice, data, imagery, and video to the tactical edge (i.e., the forward battle lines
Tanasugarn, Lokachet; Natearpha, Pasit; Kongsakon, Ronnakorn; Chaosaowapa, Marshima; Choatwongwachira, Woraphon; Seanglaw, Dussadee; Kiratisin, Pattarachai; Namatra, Chakrapong; Srinonprasert, Varalak; Nimmannnit, Akarin; Vannabhum, Manmas; Laohapand, Tawee; Kuptniratsaikul, Vilai
2015-03-01
This study aims to preliminarily evaluate effect on physical properties of shoulder joints and cognitive function after practicing Rue-si-dad-ton, a Thai traditional exercise using the postures of the hermit doing body contortion which still lacks systematically conducted evidence-based regarding its benefits. Thirty-seven participants who have routinely worked on computer at least 3 hours per day were recruited and randomized into intervention (n = 19) or control group (n = 18). Physical effect on shoulder joints was evaluated by measuring shoulder range of motion (ROM) and evaluating shoulder function with the American Shoulder & Elbow Surgeons Standardized Shoulder Assessment Form. Cognitive function was determined by Verbal Fluency Test, Trail Maker B Test, and Digit Span Test. Both study groups were assessed by all tests at the beginning and at the end of study by blinded assessors. The intervention group performed 3 postures of Rue-si-dad-ton exercise (an hour per day for 4 days by a well-trained instructor) before thefinal measurement. Only left and right shoulder flexion of the intervention group (p-value = 0.006 and 0.010 respectively) showed significant increment compared with the control group using ANCOVA test with baseline adjusted as covariate. Other variables, including joint and cognitive function, indicated no significant changes between groups. No complications from exercise were found during the study Rue-si-dad-ton may safely help improve range of joint motion with potential benefit for joint and cognitive function. Additional extensive studies with adequate number of participants and longer period of exercise are warranted.
A new distraction arthroplasty device using magnetic force; a cadaveric study.
Kamei, Goki; Ochi, Mitsuo; Okuhara, Atsushi; Fujimiya, Mineko; Deie, Masataka; Adachi, Nobuo; Nakamae, Atsuo; Nakasa, Tomoyuki; Ohkawa, Shingo; Takazawa, Kobun; Eguchi, Akio; Katou, Tomohiro; Takada, Tsuyoshi; Usman, Muhammad Andry
2013-04-01
It is difficult for an articular cartilage injury to repair spontaneously. There are many procedures for treating cartilage injury, however there is no standard procedure for middle-aged patients who have diffuse knee osteoarthritis, especially of the lateral compartment. Therefore, Ochi developed a new distraction device that uses magnetic power to enlarge a joint space and promote cartilage regeneration with microfracture. The purpose of this study is to evaluate this new distraction arthroplasty system by using the cadaveric knee. This study used ten knees from six cadavers that were embalmed by Thiel's methods. The medial and lateral joint space was measured by AP radiographic view before and after distraction, and after weight-bearing to evaluate the joint distraction. The contact pressure of the medial and lateral compartments at the knee extension position by using a prescale film system was measured before and after weight-bearing with a 15 or 30-kg weight-bearing load to evaluate the effectiveness of this device. The lateral joint space significantly increased from the pre-distraction to the post-distraction; however, it did not change significantly between post-distraction and post-weight-bearing. With a 15 or 30-kg weight-bearing load, the contact pressure of the lateral compartment significantly decreased from the pre-distraction to the post-distraction. The most important advantage of this device is that it maintains a continuous distraction tension and enables almost the full range of motion of the knee. We believe that joint distraction by using magnetic force can be a promising option for cartilage injury in middle-aged patients. Copyright © 2013 Elsevier Ltd. All rights reserved.
[Relevance of MRI After Closed Reduction of Traumatic Hip Dislocation in Children].
Strüwind, Christoph Mauritz; von Rüden, Christian; Thannheimer, Andreas; Bühren, Volker; Schneidmueller, Dorien
2018-05-14
Traumatic hip dislocation in children and adolescents is a rare entity that typically results from high-energy trauma. After closed joint reduction, further treatment depends on the specific pattern of the lesion as identified using cross sectional imaging. The aim of this retrospective analysis was to evaluate relevant side effects after traumatic hip dislocation in children and adolescents in order to examine the need for focused diagnostics. This retrospective analysis covered 8 adolescents under 18 years suffering isolated traumatic hip joint dislocation between 2001 and 2017. In all patients, closed joint reduction was performed immediately after admission to the emergency room. In order to evaluate the complete extent of the injury, 5 patients received an MRI and 3 patients a CT scan following closed joint reduction. Two female and 6 male patients with a median age of 11 (range 5 - 16) years were included. In 2 cases, a free joint body was detected in the posterior joint gap in the posttraumatic CT scan after closed joint reduction. Interposition of the labrum into the joint gap was detected intraoperatively in both cases. In one patient who received posttraumatic MRI, labral interposition into the joint gap was observed after closed reduction. These findings were confirmed intraoperatively. In 4 other patients, no posttraumatic labral lesion was detected in the MRI after closed reduction. The reported side effects included ruptured anterior inferior iliac spine and ruptured femoral head ligament. MRI is gaining increasing importance following traumatic hip dislocation in children and adolescents. A missing chondral or osteochondral fragment in the CT scan does not exclude a labral lesion or interposition. Therefore, MRI following closed reduction is mandatory in any case. Georg Thieme Verlag KG Stuttgart · New York.
Intema, Femke; Van Roermund, Peter M; Marijnissen, Anne C A; Cotofana, Sebastian; Eckstein, Felix; Castelein, Rene M; Bijlsma, Johannes W J; Mastbergen, Simon C; Lafeber, Floris P J G
2011-01-01
Background Modification of joint tissue damage is challenging in late-stage osteoarthritis (OA). Few options are available for treating end-stage knee OA other than joint replacement. Objectives To examine whether joint distraction can effectively modify knee joint tissue damage and has the potential to delay prosthesis surgery. Methods 20 patients (<60 years) with tibiofemoral OA were treated surgically using joint distraction. Distraction (∼5 mm) was applied for 2 months using an external fixation frame. Tissue structure modification at 1 year of follow-up was evaluated radiographically (joint space width (JSW)), by MRI (segmentation of cartilage morphology) and by biochemical markers of collagen type II turnover, with operators blinded to time points. Clinical improvement was evaluated by Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Visual Analogue Scale (VAS) pain score. Results Radiography demonstrated an increase in mean and minimum JSW (2.7 to 3.6 mm and 1.0 to 1.9 mm; p<0.05 and <0.01). MRI revealed an increase in cartilage thickness (2.4 to 3.0 mm; p<0.001) and a decrease of denuded bone areas (22% to 5%; p<0.001). Collagen type II levels showed a trend towards increased synthesis (+103%; p<0.06) and decreased breakdown (−11%; p<0.08). The WOMAC index increased from 45 to 77 points, and VAS pain decreased from 73 to 31 mm (both p<0.001). Conclusions Joint distraction can induce tissue structure modification in knee OA and could result in clinical benefit. No current treatment is able to induce such changes. Larger, longer and randomised studies on joint distraction are warranted. PMID:21565898
NASA Astrophysics Data System (ADS)
Ishibashi, Takuya; Watanabe, Noriaki; Hirano, Nobuo; Okamoto, Atsushi; Tsuchiya, Noriyoshi
2015-01-01
The present study evaluates aperture distributions and fluid flow characteristics for variously sized laboratory-scale granite fractures under confining stress. As a significant result of the laboratory investigation, the contact area in fracture plane was found to be virtually independent of scale. By combining this characteristic with the self-affine fractal nature of fracture surfaces, a novel method for predicting fracture aperture distributions beyond laboratory scale is developed. Validity of this method is revealed through reproduction of the results of laboratory investigation and the maximum aperture-fracture length relations, which are reported in the literature, for natural fractures. The present study finally predicts conceivable scale dependencies of fluid flows through joints (fractures without shear displacement) and faults (fractures with shear displacement). Both joint and fault aperture distributions are characterized by a scale-independent contact area, a scale-dependent geometric mean, and a scale-independent geometric standard deviation of aperture. The contact areas for joints and faults are approximately 60% and 40%. Changes in the geometric means of joint and fault apertures (µm), em, joint and em, fault, with fracture length (m), l, are approximated by em, joint = 1 × 102 l0.1 and em, fault = 1 × 103 l0.7, whereas the geometric standard deviations of both joint and fault apertures are approximately 3. Fluid flows through both joints and faults are characterized by formations of preferential flow paths (i.e., channeling flows) with scale-independent flow areas of approximately 10%, whereas the joint and fault permeabilities (m2), kjoint and kfault, are scale dependent and are approximated as kjoint = 1 × 10-12 l0.2 and kfault = 1 × 10-8 l1.1.
Lv, Xin; Liu, Yuan; Zhou, Song; Wang, Qiang; Gu, Houyun; Fu, Xiaoxing; Ding, Yi; Zhang, Bin; Dai, Min
2016-08-15
Sagittal spinopelvic alignment changes associated with degenerative facet joint arthritis have been assessed in a few studies. It has been documented that patients with facet joint degeneration have higher pelvic incidence, but the relationship between facet joint degeneration and other sagittal spinopelvic alignment parameters is still disputed. Our purpose was to evaluate the correlation between the features of sagittal spinopelvic alignment and facet joint degeneration. Imaging data of 140 individuals were retrospectively analysed. Lumbar lordosis, pelvic tilt (PT), pelvic incidence (PI), sacral slope, and height of the lumbar intervertebral disc were measured on lumbar X-ray plates. Grades of facet joint degeneration were evaluated from the L2 to S1 on CT scans. Spearman's rank correlation coefficient and Student's t-test were used for statistical analyses, and a P-value <0.05 was considered statistically significant. PI was positively associated with degeneration of the facet joint at lower lumbar levels (p < 0.001 r = 0.50 at L5/S1 and P = 0.002 r = 0.25 at L4/5). A significant increase of PT was found in the severe degeneration group compared with the mild degeneration group: 22.0° vs 15.7°, P = 0.034 at L2/3;21.4°vs 15.1°, P = 0.006 at L3/4; 21.0° vs 13.5°, P = 0.000 at L4/5; 20.8° vs 12.1°, P = 0.000 at L5/S1. Our results indicate that a high PI is a predisposing factor for facet joint degeneration at the lower lumbar spine, and that severe facet joint degeneration may accompany with greater PT at lumbar spine.
Fukae, Jun; Kon, Yujiro; Henmi, Mihoko; Sakamoto, Fumihiko; Narita, Akihiro; Shimizu, Masato; Tanimura, Kazuhide; Matsuhashi, Megumi; Kamishima, Tamotsu; Atsumi, Tatsuya; Koike, Takao
2010-05-01
To investigate the relationship between synovial vascularity assessed by quantitative power Doppler sonography (PDS) and progression of structural bone damage in a single finger joint in patients with rheumatoid arthritis (RA). We studied 190 metacarpophalangeal (MCP) joints and 190 proximal interphalangeal (PIP) joints of 19 patients with active RA who had initial treatment with disease-modifying antirheumatic drugs (DMARDs). Patients were examined by clinical and laboratory assessments throughout the study. Hand and foot radiography was performed at baseline and the twentieth week. Magnetic resonance imaging (MRI) was performed at baseline. PDS was performed at baseline and the eighth week. Synovial vascularity was evaluated according to both quantitative and semiquantitative methods. Quantitative PDS was significantly correlated with the enhancement rate of MRI in each single finger joint. Comparing quantitative synovial vascularity and radiographic change in single MCP or PIP joints, the level of vascularity at baseline showed a significant positive correlation with radiographic progression at the twentieth week. The change of vascularity in response to DMARDs, defined as the percentage change in vascularity by the eighth week from baseline, was inversely correlated with radiographic progression in each MCP joint. The quantitative PDS method was more useful than the semiquantitative method for the evaluation of synovial vascularity in a single finger joint. The change of synovial vascularity in a single finger joint determined by quantitative PDS could numerically predict its radiographic progression. Using vascularity as a guide to consider a therapeutic approach would have benefits for patients with active RA.
Results and Analysis from Space Suit Joint Torque Testing
NASA Technical Reports Server (NTRS)
Matty, Jennifer E.; Aitchison, Lindsay
2009-01-01
A space suit s mobility is critical to an astronaut s ability to perform work efficiently. As mobility increases, the astronaut can perform tasks for longer durations with less fatigue. The term mobility, with respect to space suits, is defined in terms of two key components: joint range of motion and joint torque. Individually these measures describe the path which in which a joint travels and the force required to move it through that path. Previous space suits mobility requirements were defined as the collective result of these two measures and verified by the completion of discrete functional tasks. While a valid way to impose mobility requirements, such a method does necessitate a solid understanding of the operational scenarios in which the final suit will be performing. Because the Constellation space suit system requirements are being finalized with a relatively immature concept of operations, the Space Suit Element team elected to define mobility in terms of its constituent parts to increase the likelihood that the future pressure garment will be mobile enough to enable a broad scope of undefined exploration activities. The range of motion requirements were defined by measuring the ranges of motion test subjects achieved while performing a series of joint maximizing tasks in a variety of flight and prototype space suits. The definition of joint torque requirements has proved more elusive. NASA evaluated several different approaches to the problem before deciding to generate requirements based on unmanned joint torque evaluations of six different space suit configurations being articulated through 16 separate joint movements. This paper discusses the experiment design, data analysis and results, and the process used to determine the final values for the Constellation pressure garment joint torque requirements.
2012-12-01
Makeup for the CASO (After Deputy Assistant Secretary of Defense for Manufacturing and Industrial Base, n.d., p. 7) .......73 xiv Figure 26. JCASO...Augmentation Program CAP Crisis Action Planning CASO Contingency Acquisition Support Office CBP Capability-Based Planning CCAS Contingency...enhance joint doctrine; 69 Develop and refine joint non-acquisition OCS training and education and ensure its inclusion in joint exercises; Identify
Morphology and Mobility of the Reconstructed Basilar Joint of the Pollicized Index Finger.
Strugarek-Lecoanet, Clotilde; Chevrollier, Jérémie; Pauchard, Nicolas; Blum, Alain; Dap, François; Dautel, Gilles
2016-09-01
To evaluate outcome and function of the reconstructed basilar thumb joint after index finger pollicization in patients presenting congenital thumb deficiency. Plain radiographs and 4-dimensional dynamic volume computed tomography scan were used to evaluate the outcome of 23 pollicizations performed on 14 children between 1996 and 2009. The mean follow-up was 8 years. Patients performed continuous movements of thumb opposition during the imaging studies. Four-dimensional scan images made it possible to visualize mobility within the reconstructed joint. In 14 cases, union occurred in the metacarpal head/metacarpal base interface. In the 9 other cases, there was a nonunion at this interface. The reconstructed joint was mobile in 20 cases, including 3 in which there was also mobility at the site of the nonunion. In 3 cases in our series, mobility was present only at the site of the nonunion, between the base and the head of the second metacarpal. Remodeling and flattening out of the metacarpal head occurred in 16 of 23 cases. The transposed metacarpal head remained spherical in 7 cases. The reconstructed joint adapts, both morphologically and functionally, allowing movement on all 3 spatial planes. Existing mechanical constraints on the reconstructed joint may explain its remodeled appearance. Therapeutic IV. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Evaluation of Rhenium Joining Methods
NASA Technical Reports Server (NTRS)
Reed, Brian D.; Morren, Sybil H.
1995-01-01
Coupons of rhenium-to-Cl03 flat plate joints, formed by explosive and diffusion bonding, were evaluated in a series of shear tests. Shear testing was conducted on as-received, thermally-cycled (100 cycles, from 21 to 1100 C), and thermally-aged (3 and 6 hrs at 1100 C) joint coupons. Shear tests were also conducted on joint coupons with rhenium and/or Cl03 electron beam welded tabs to simulate the joint's incorporation into a structure. Ultimate shear strength was used as a figure of merit to assess the effects of the thermal treatment and the electron beam welding of tabs on the joint coupons. All of the coupons survived thermal testing intact and without any visible degradation. Two different lots of as-received, explosively-bonded joint coupons had ultimate shear strengths of 281 and 310 MPa and 162 and 223 MPa, respectively. As-received, diffusion-bonded coupons had ultimate shear strengths of 199 and 348 MPa. For the most part, the thermally-treated and rhenium weld tab coupons had shear strengths slightly reduced or within the range of the as-received values. Coupons with Cl03 weld tabs experienced a significant reduction in shear strength. The degradation of strength appeared to be the result of a poor heat sink provided during the electron beam welding. The Cl03 base material could not dissipate heat as effectively as rhenium, leading to the formation of a brittle rhenium-niobium intermetallic.
Havet, Eric; Gabrion, Antoine; Leiber-Wackenheim, Frederic; Vernois, Joël; Olory, Bruno; Mertl, Patrice
2007-06-01
Restoring the joint line level is one of the surgical challenges during revision of total knee arthroplasty. The position of the tibial surface is commonly estimated by its distance to the apex of fibular head, but no study evaluating this distance accurately has been published yet. The purpose of this work was to study the distance between the knee joint line and the apex of the fibular head and the proximal tibia, particularly the tibial tuberosity. Variability with clinical data and relations with other local measurements have been evaluated on knee radiographs (an antero-posterior view, a medio-lateral view and an anteroposterior full length view) of 100 subjects (125 knees). Results showed no correlation between the joint line-fibular head apex distance and any clinical data of the patients, or any other performed measurements. Relations between tibial measurements and the sexe or the height of the subjects were noted. Besides, the review of the 25 bilateral cases did not show statistically significant side difference but the descriptive analysis showed too large discrepancies for the joint line-fibular head apex distance to be used as a landmark. We conclude that the fibular head apex cannot be used as a morphologic landmark to determine the knee joint line position. Its interest in clinical and surgical practice must be discussed.
Update on slip and wear in multi-layer azimuth track systems
NASA Astrophysics Data System (ADS)
Juneja, Gunjeet; Kan, Frank W.; Antebi, Joseph
2006-06-01
Many antennas, such as the 100-m Green Bank Telescope, use a wheel-on-track systems in which the track segments consist of wear plates mounted on base plates. The wear plates are typically 2 to 3 inches thick and are case hardened or through hardened. The base plates are usually 3 to 4 times thicker than the wear plates and are not hardened. The wear plates are typically connected to the base plates using bolts. The base plates are supported on grout and anchored to the underlying concrete foundation. For some antennas, slip has been observed between the wear plate and base plate, and between the base plate and the grout, with the migration in the wheel rolling direction. In addition, there has been wear at the wear plate/base plate interface. This paper is an update on the evaluation of GBT track retrofit. The paper describes the use of three-dimensional non-linear finite element analyses to understand and evaluate the behavior of (1) the existing GBT wheel-on-track system with mitered joints, and (2) the various proposed modifications. The modifications include welding of the base plate joints, staggering of the wear plate joints from the base plate joints, changing thickness of the wear plate, and increasing bolt diameter and length. Parameters included in the evaluation were contact pressure, relative slip, wear at the wear plate/base plate interface, and bolt shears and moments.
NASA Astrophysics Data System (ADS)
Scarselli, G.; Ciampa, F.; Ginzburg, D.; Meo, M.
2015-04-01
Nonlinear ultrasonic non-destructive evaluation (NDE) methods can be used for the identification of defects within adhesive bonds as they rely on the detection of nonlinear elastic features for the evaluation of the bond strength. In this paper the nonlinear content of the structural response of a single lap joint subjected to ultrasonic harmonic excitation is both numerically and experimentally evaluated to identify and characterize the defects within the bonded region. Different metallic samples with the same geometry were experimentally tested in order to characterize the debonding between two plates by using two surface bonded piezoelectric transducers in pitch-catch mode. The dynamic response of the damaged samples acquired by the single receiver sensor showed the presence of higher harmonics (2nd and 3rd) and subharmonics of the fundamental frequencies. These nonlinear elastic phenomena are clearly due to nonlinear effects induced by the poor adhesion between the two plates. A new constitutive model aimed at representing the nonlinear material response generated by the interaction of the ultrasonic waves with the adhesive joint is also presented. Such a model is implemented in an explicit FE software and uses a nonlinear user defined traction-displacement relationship implemented by means of a cohesive material user model interface. The developed model is verified for the different geometrical and material configurations. Good agreement between the experimental and numerical nonlinear response showed that this model can be used as a simple and useful tool for understanding the quality of the adhesive joint.
First metatarsalphalangeal joint arthrodesis: evaluation of plate and screw fixation.
Bennett, Gordon L; Sabetta, James
2009-08-01
First metatarsalphalangeal joint (MTPJ) arthrodesis is a commonly performed procedure for the treatment of a variety of conditions affecting the hallux. There are several different methods to accomplish the fusion. We utilized a method incorporating a ball and cup preparation of the joint, followed by stabilization of the arthrodesis site utilizing the Accutrak congruent first MTPJ fusion set. We prospectively evaluated two hundred consecutive patients who underwent first MTPJ arthrodeses utilizing the Accutrak congruent first MTPJ fusion set. Patients were evaluated preoperatively, postoperatively, and at a final followup, utilizing the AOFAS forefoot scoring system. Two hundred consecutive patients underwent first MTPJ arthrodeses by the same surgeon. All but three feet (230/233) (98.7%) went on to solidly fuse. Three of the patients did not fuse solidly. One patient broke two of the screws, and the other two patients did not have hardware failure. All patients dramatically improved their AOFAS scores compared with pre-surgical values. There were three minor hardware problems in the group of patients who solidly fused their joint. We concluded that a solid first MTPJ fusion results in excellent function and pain relief. The Accutrak first MTPJ fusion system would appear to be an ideal implant system to accomplish a fusion because of its low profile, strength, and ease of use. Compared to other methods we have used, this procedure results in a very high rate of fusion, with minimal complications and excellent patient satisfaction.
NASA Astrophysics Data System (ADS)
Zhang, Zhen; Liu, Menglong; Liao, Yaozhong; Su, Zhongqing; Xiao, Yi
2018-03-01
The significance of evaluating bolt tightness in engineering structures, preferably in a continuous manner, cannot be overemphasized. With hybrid use of high-order harmonics (HOH) and spectral sidebands, a contact acoustic nonlinearity (CAN)-based monitoring framework is developed for detecting bolt loosening and subsequently evaluating the residual torque on a loose bolt. Low-frequency pumping vibration is introduced into the bolted joint to produce a "breathing" effect at the joining interface that modulates the propagation characteristics of a high-frequency probing wave when it traverses the bolt, leading to the generation of HOH and vibro-acoustic nonlinear distortions (manifested as sidebands in the signal spectrum). To gain insight into the mechanism of CAN generation and to correlate the acquired nonlinear responses of a loose joint with the residual torque remaining on the bolt, an analytical model based on micro-contact theory is established. Two types of nonlinear index, respectively exploiting the induced HOH and spectral sidebands, are defined without dependence on excitation intensity and are experimentally demonstrated to be effective in continuously monitoring bolt loosening in both aluminum-aluminum and composite-composite bolted joints. Taking a step further, variation of the index pair is quantitatively associated with the residual torque on a loose bolt. The approach developed provides a reliable method of continuous evaluation of bolt tightness in both composite and metallic joints, regardless of their working conditions, from early awareness of bolt loosening at an embryonic stage to quantitative estimation of residual torque.
NASA Technical Reports Server (NTRS)
Lewis, Pattie
2005-01-01
Headquarters National Aeronautics and Space Administration (NASA) chartered the Acquisition Pollution Prevention (AP2) Office to coordinate agency activities affecting pollution prevention issues identified during system and component acquisition and sustainment processes. The primary objectives of the AP2 Office are to: (1) Reduce or eliminate the use of hazardous materials (HazMats) or hazardous processes at manufacturing, remanufacturing, and sustainment locations. (2) A void duplication of effort in actions required to reduce or eliminate HazMats through joint center cooperation and technology sharing. This project will identify, evaluate and approve alternative surface preparation technologies for use at NASA and Air Force Space Command (AFSPC) installations. Materials and processes will be evaluated with the goal of selecting those processes that will improve corrosion protection at critical systems, facilitate easier maintenance activity, extend maintenance cycles, eliminate flight hardware contamination and reduce the amount of hazardous waste generated. This Joint Test Protocol (JTP) contains the critical requirements and tests necessary to qualify alternative Low-Emission Surface Preparation/Depainting Technologies for Structural Steel Applications. These tests were derived from engineering, performance, and operational impact (supportability) requirements defined by a consensus of NASA and Air Force Space Command (AFSPC) participants. The Field Test Plan (FTP), entitled Joint Test Protocol for Validation of Alternative Low Emission Surface Preparation/Depainting Technologies for Structural Steel, prepared by ITB, defines the field evaluation and testing requirements for validating alternative surface preparation/depainting technologies and supplements the JTP.
Synthesized multi-station tribo-test system for bio-tribological evaluation in vitro
NASA Astrophysics Data System (ADS)
Wu, Tonghai; Du, Ying; Li, Yang; Wang, Shuo; Zhang, Zhinan
2016-07-01
Tribological tests play an important role on the evaluation of long-term bio-tribological performances of prosthetic materials for commercial fabrication. Those tests focus on the motion simulation of a real joint in vitro with only normal loads and constant velocities, which are far from the real friction behavior of human joints characterized with variable loads and multiple directions. In order to accurately obtain the bio-tribological performances of artificial joint materials, a tribological tester with a miniature four-station tribological system is proposed with four distinctive features. Firstly, comparability and repeatability of a test are ensured by four equal stations of the tester. Secondly, cross-linked scratch between tribo-pairs of human joints can be simulated by using a gear-rack meshing mechanism to produce composite motions. With this mechanism, the friction tracks can be designed by varying reciprocating and rotating speeds. Thirdly, variable loading system is realized by using a ball-screw mechanism driven by a stepper motor, by which loads under different gaits during walking are simulated. Fourthly, dynamic friction force and normal load can be measured simultaneously. The verifications of the performances of the developed tester show that the variable frictional tracks can produce different wear debris compared with one-directional tracks, and the accuracy of loading and friction force is within ±5%. Thus the high consistency among different stations can be obtained. Practically, the proposed tester system could provide more comprehensive and accurate bio-tribological evaluations for prosthetic materials.
Dief, A E; Mostafa, D K; Sharara, G M; Zeitoun, T H
2015-04-01
Hydrogen sulfide (H2S) is rapidly gaining ground as a physiological mediator of inflammation, but there is no clear consensus as to its precise role in inflammation. Therefore, this study was undertaken to evaluate the effects of ATB-346 as a novel H2S-releasing naproxen compared to naproxen, as a traditional non-steroidal anti-inflammatory drug on zymosan induced mono-arthritis in rats. Male Wistar rats (n=48) were randomly assigned to four main groups: normal control, untreated arthritis, Naproxen and ATB-346 treated groups. Mono-arthritis was induced by intra-articular injection of zymosan into the knee joints. Mechanical hypernociception and joint swelling were evaluated at 6 hours and 5 days. Inflammatory cellular recruitment and adherence, tumor necrosis factor alpha, nuclear factor kappa β, total sulfide levels, and histological changes were evaluated in knee lavages, blood or joint tissues at selected time points. Zymosan injection evoked knee inflammation and pain as characterized by mechanical hypernociception, impaired gait, joint swelling with inflammatory exudation and histological changes. Treatment with ATB-346 attenuated nociceptive responses, inflammatory cellular and biochemical changes in comparison to naproxen. Only ATB-346 was able to suppress neutrophil adherence and to preserve normal articular structure. H2S releasing naproxen represents an advancement over the parent drug, naproxen. Apart from the superior anti-inflammatory and anti-noceiceptive activity, ATB-346 offered a distinguished chondroprotective effect and is almost devoid from naproxen deleterious effects on articular cartilage.
Global Body Posture Evaluation in Patients with Temporomandibular Joint Disorder
Saito, Eliza Tiemi; Akashi, Paula Marie Hanai; de Camargo Neves Sacco, Isabel
2009-01-01
AIM: To identify the relationship between anterior disc displacement and global posture (plantar arches, lower limbs, shoulder and pelvic girdle, vertebral spine, head and mandibles). Common signs and symptoms of anterior disc displacement were also identified. INTRODUCTION: Global posture deviations cause body adaptation and realignment, which may interfere with the organization and function of the temporomandibular joint. METHODS : Global posture evaluation was performed in a group of 10 female patients (20 to 30 years of age) with temporomandibular joint disc displacement and in a control group of 16 healthy female volunteers matched for age, weight and height. Anterior disc displacement signs, symptoms and the presence of parafunctional habits were also identified through interview. RESULTS: Patients with disc displacement showed a higher incidence of pain in the temporomandibular joint area, but there were no differences in parafunctional habits between the groups. In the disc displacement group, postural deviations were found in the pelvis (posterior rotation), lumbar spine (hyperlordosis), thoracic spine (rectification), head (deviation to the right) and mandibles (deviation to the left with open mouth). There were no differences in the longitudinal plantar arches between the groups. CONCLUSION: Our results suggest a close relationship between body posture and temporomandibular disorder, though it is not possible to determine whether postural deviations are the cause or the result of the disorder. Hence, postural evaluation could be an important component in the overall approach to providing accurate prevention and treatment in the management of patients with temporomandibular disorder. PMID:19142549
Nomoto, Rie; Takayama, Yasuko; Tsuchida, Fujio; Nakajima, Hiroyuki
2010-12-01
The purpose of this study was to measure the porosity in different laser welded cast alloys non-destructively using X-ray micro-focus computerized tomography (micro-CT) and to evaluate the effect of porosity on the tensile strength of the welded joints. The welding procedure was conducted in rectangular cast metals, CoCr, Ti and platinum added gold alloy (AuPt). The metal plates were butted CoCr to CoCr (CoCr/CoCr) or Ti to Ti (Ti/Ti) for welding of similar metals and Ti to AuPt (Ti/AuPt) for welding of dissimilar metals. Specimens were welded under several laser-welding conditions; with groove (normal), without groove (no groove), spatter, crack, or no overlapped welding (no overlap) (n=5). Porosity in the welded area was evaluated using a micro-CT. Tensile strength of the welded specimens was measured at a crosshead speed of 1mm/min. Multiple comparisons of the group means were performed using ANOVA and Fisher's multiple comparisons test (α=.05). The relationship between the porosity and the tensile strength was investigated with a regression analysis. Three-dimensional images of Ti/AuPt could not be obtained due to metal artifacts and the tensile specimens of Ti/AuPt were debonded prior to the tensile test. All other welded specimens had porosity in the welded area and the porosities ranged from 0.01% to 0.17%. The fractures of most of the CoCr/CoCr and Ti/Ti specimens occurred in the parent metals. Joint strength had no relationship with the porosity in the welded area (R(2)=0.148 for CoCr/CoCr, R(2)=0.088 for Ti/Ti, respectively). The small amount of porosity caused by the laser-welding procedures did not affect the joint strength. The joint strength of Ti/AuPt was too weak to be used clinically. Copyright © 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Simplified Design Method for Tension Fasteners
NASA Astrophysics Data System (ADS)
Olmstead, Jim; Barker, Paul; Vandersluis, Jonathan
2012-07-01
Tension fastened joints design has traditionally been an iterative tradeoff between separation and strength requirements. This paper presents equations for the maximum external load that a fastened joint can support and the optimal preload to achieve this load. The equations, based on linear joint theory, account for separation and strength safety factors and variations in joint geometry, materials, preload, load-plane factor and thermal loading. The strength-normalized versions of the equations are applicable to any fastener and can be plotted to create a "Fastener Design Space", FDS. Any combination of preload and tension that falls within the FDS represents a safe joint design. The equation for the FDS apex represents the optimal preload and load capacity of a set of joints. The method can be used for preliminary design or to evaluate multiple pre-existing joints.
Training Objectives, Transfer, Validation and Evaluation: A Sri Lankan Study
ERIC Educational Resources Information Center
Wickramasinghe, Vathsala M.
2006-01-01
Using a stratified random sample, this paper examines the training practices of setting objectives, transfer, validation and evaluation in Sri Lanka. The paper further sets out to compare those practices across local, foreign and joint-venture companies based on the assumption that there may be significant differences across companies of different…
Metabolic Assessment of Suited Mobility Using Functional Tasks
NASA Technical Reports Server (NTRS)
Norcross, J. R.; McFarland, S. M.; Ploutz-Snyder, Robert
2016-01-01
Existing methods for evaluating extravehicular activity (EVA) suit mobility have typically focused on isolated joint range of motion or torque, but these techniques have little to do with how well a crewmember functionally performs in an EVA suit. To evaluate suited mobility at the system level through measuring metabolic cost (MC) of functional tasks.
32 CFR 700.405 - Delegated authority and responsibility.
Code of Federal Regulations, 2011 CFR
2011-07-01
... motivation of Navy personnel and the prestige of a Navy career; (4) To plan and provide health care for..., test, and evaluation to plan and provide for the conduct of test and evaluation which are adequate and... strategic plans and policies and participate in the formulation of Joint and combined strategic plans and...
DOT National Transportation Integrated Search
2000-01-19
This document serves as the proceedings form an evaluation workshop that focused on Intelligent Transportation Systems (ITS) applications at highway and rail crossings. Reports delivered contain information from seven U.S. sites where ITS technologie...
Entrepreneurship Education in the Arab States. Final Evaluation Report
ERIC Educational Resources Information Center
Lamloumi, Jilani
2013-01-01
The report involves the findings of the final evaluation of the regional entrepreneurship education project in Arab States component II (2011-2012) (see ED560497), which is a joint activity between UNESCO and StratREAL Foundation. It aims to help the development of educational policies enabling the integration of entrepreneurship education within…
Youth Social Action Trials: Youth United. Evaluation Report and Executive Summary
ERIC Educational Resources Information Center
Gorard, Stephen; See, Beng Huat; Siddiqui, Nadia; Smith, Emma; White, Patrick
2016-01-01
The intervention evaluated here is one of two "youth social action" projects jointly funded by the Education Endowment Foundation, the U.K. Cabinet Office, the Pears Foundation and the Stone Family Foundation. It was delivered by the Youth United Foundation (YUF) and involved uniformed youth organisations being established in schools in…
DOT National Transportation Integrated Search
1976-01-01
In response to House Joint Resolution #41, an evaluation of the movement of 14-foot wide manufactured housing units was conducted on Virginia highways. The purpose of the study was to provide information concerning the transportation characteristics ...
[Mixed design for the evaluation of the Mesoamerica Health 2015 initiative].
Gutiérrez, Juan Pablo; Téllez-Rojo, Marta María; Torres, Pilar; Romero, Martín; Bertozzi, Stefano M
2011-01-01
Since the Salud Mesoamerica 2015 initiative (SM-2015) aim is to improve health and nutrition conditions of those most vulnerable in Mesoamerica, the goal of the evaluation is to generate evidence of the joint effectiveness of a package of interventions designed to improve the health conditions. We propose a mix design for the evaluation, which will allow to know the magnitude of changes attributable to the interventions, as well as the meanings of these changes for the target population, taking into account the specificities of each country. The main axis of this design is a locality panel where information about individuals, households, and health facilities (first and second level) will also be collected. The evaluation design described in this paper was developed between June and December, 2009, and it was integrated during workshops in Cuernavaca (Mexico), Managua (Nicaragua), and San Jose (Costa Rica). The proposed design will allow to generate evidence about the joint effectiveness of the package of interventions proposed for the SM-2015. The success of this design rests on the political commitment of countries and donors.
Optimization and evaluation of a proportional derivative controller for planar arm movement.
Jagodnik, Kathleen M; van den Bogert, Antonie J
2010-04-19
In most clinical applications of functional electrical stimulation (FES), the timing and amplitude of electrical stimuli have been controlled by open-loop pattern generators. The control of upper extremity reaching movements, however, will require feedback control to achieve the required precision. Here we present three controllers using proportional derivative (PD) feedback to stimulate six arm muscles, using two joint angle sensors. Controllers were first optimized and then evaluated on a computational arm model that includes musculoskeletal dynamics. Feedback gains were optimized by minimizing a weighted sum of position errors and muscle forces. Generalizability of the controllers was evaluated by performing movements for which the controller was not optimized, and robustness was tested via model simulations with randomly weakened muscles. Robustness was further evaluated by adding joint friction and doubling the arm mass. After optimization with a properly weighted cost function, all PD controllers performed fast, accurate, and robust reaching movements in simulation. Oscillatory behavior was seen after improper tuning. Performance improved slightly as the complexity of the feedback gain matrix increased. Copyright 2009 Elsevier Ltd. All rights reserved.
Optimization and evaluation of a proportional derivative controller for planar arm movement
Jagodnik, Kathleen M.; van den Bogert, Antonie J.
2013-01-01
In most clinical applications of functional electrical stimulation (FES), the timing and amplitude of electrical stimuli have been controlled by open-loop pattern generators. The control of upper extremity reaching movements, however, will require feedback control to achieve the required precision. Here we present three controllers using proportional derivative (PD) feedback to stimulate six arm muscles, using two joint angle sensors. Controllers were first optimized and then evaluated on a computational arm model that includes musculoskeletal dynamics. Feedback gains were optimized by minimizing a weighted sum of position errors and muscle forces. Generalizability of the controllers was evaluated by performing movements for which the controller was not optimized, and robustness was tested via model simulations with randomly weakened muscles. Robustness was further evaluated by adding joint friction and doubling the arm mass. After optimization with a properly weighted cost function, all PD controllers performed fast, accurate, and robust reaching movements in simulation. Oscillatory behavior was seen after improper tuning. Performance improved slightly as the complexity of the feedback gain matrix increased. PMID:20097345
Gondim Teixeira, P A; Bravetti, M; Hossu, G; Lecocq, S; Petit, D; Loeuille, D; Blum, A
2017-12-01
To evaluate the impact of coil design and motion-resistant sequences on the quality of sacroiliac magnetic resonance imaging (MRI) examination in patients with spondyloarthropathy. One hundred and twenty-one patients with suspected sacroiliitis and referred for MRI of the sacroiliac joints were retrospectively evaluated with MRI at 3-Tesla. There were 78 women and 43 men with a mean age of 36.7±11.5 (SD) years (range: 15.8-78.4 years). Conventional and motion-resistant fat-saturated fast-spin echo T2-weighted sequences were performed with two different coils. Image quality was subjectively evaluated by two independent readers (R1 and R2) using a four-point scale. Confidence in the identification of bone marrow edema pattern (BMEP) was also evaluated subjectively using a three-point scale. Phased array body coil yielded improved image quality compared to surface coil (14.1 to 30.4% for R1 and 14.6 to 25.7% for R2; P<0.0001). The impact of the sequence type on quality was also statistically significant (P=0.0046). BMEP was identified in 40 patients and best inter-reader agreement was obtained using the combination of phased-array body coil with motion-resistant T2-weighted sequence (kappa 0.990). The smallest number of indeterminate BMEP zones was seen on MRI set acquired with the phased-array body coil and motion-resistant T2-weighted sequence. Phased array body coil and motion-resistant T2-weighted sequences perform better than surface coil and conventional T2-weighted sequences for the evaluation of sacroiliac joints, increasing confidence in the identification of BMEP. Copyright © 2017 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Study on the Strength of GFRP/Stainless Steel Adhesive Joints Reinforced with Glass Mat
NASA Astrophysics Data System (ADS)
Iwasa, Masaaki
The adhesive strengths of glass fiber reinforced plastics/metal adhesive joints reinforced with glass mat under tensile shear loads and tensile loads were investigated analytically and experimentally. First, the stress singularity parameters of the bonding edges were analyzed by FEM for various types of adhesive joints reinforced with glass mat. The shear stress and normal stress distributions near the bonding edge can be expressed by two stress singularity parameters. Second, tensile shear tests were performed on taper lap joint and taper lap joint reinforced with glass mat and tensile tests were performed on T-type adhesive joint and T-type adhesive joint reinforced with glass mat. The relationships between the loads and the crosshead displacements were measured. We concluded that reinforcing adhesive joints has a greater effect on strength under tensile load than under tensile shear load. The adhesive joints strength reinforced with glass mat can be evaluated by using stress singularity parameters.
Zhang, Mingming; Meng, Wei; Davies, T Claire; Zhang, Yanxin; Xie, Sheng Q
2016-04-01
Robot-assisted ankle assessment could potentially be conducted using sensor-based and model-based methods. Existing ankle rehabilitation robots usually use torquemeters and multiaxis load cells for measuring joint dynamics. These measurements are accurate, but the contribution as a result of muscles and ligaments is not taken into account. Some computational ankle models have been developed to evaluate ligament strain and joint torque. These models do not include muscles and, thus, are not suitable for an overall ankle assessment in robot-assisted therapy. This study proposed a computational ankle model for use in robot-assisted therapy with three rotational degrees of freedom, 12 muscles, and seven ligaments. This model is driven by robotics, uses three independent position variables as inputs, and outputs an overall ankle assessment. Subject-specific adaptations by geometric and strength scaling were also made to allow for a universal model. This model was evaluated using published results and experimental data from 11 participants. Results show a high accuracy in the evaluation of ligament neutral length and passive joint torque. The subject-specific adaptation performance is high, with each normalized root-mean-square deviation value less than 10%. This model could be used for ankle assessment, especially in evaluating passive ankle torque, for a specific individual. The characteristic that is unique to this model is the use of three independent position variables that can be measured in real time as inputs, which makes it advantageous over other models when combined with robot-assisted therapy.
The posterior transtriceps approach for elbow arthrography: a forgotten technique?
Lohman, M; Borrero, C; Casagranda, B; Rafiee, B; Towers, J
2009-05-01
To evaluate the technical feasibility of performing elbow MR arthrography via a posterior approach through the triceps. The images of 19 patients with elbow MR arthrography via a posterior transtriceps approach were retrospectively studied. The injections were performed by four musculoskeletal radiologists, using fluoroscopic guidance and a 22- or 25-gauge needle. The fluoroscopic and subsequent MR images were reviewed by two musculoskeletal radiologists and evaluated for adequacy of joint capsular distention, degree and location of contrast leakage, and presence of gas bubbles. The injection was diagnostic in all 19 patients, with a sufficient amount of contrast agent seen in the elbow joint. No significant contrast leakage occurred in 12 patients who received injections of 8 cc or less of contrast agent, but moderate contrast leakage occurred in 6/7 patients who received injections of greater than 8 cc. Contrast leakage generally occurred within the triceps myotendinous junction. No gas bubbles were identified in the injected joints. Patients often present for MR arthrography of the elbow with medial or lateral elbow pain. Contrast leakage during a radiocapitellar approach may complicate evaluation of the lateral collateral ligament or the common extensor tendon origin. Transtriceps MR arthrography offers an alternative to the more commonly used radiocapitellar approach. With injected volumes not exceeding 8 cc, the risk of significant contrast leakage is small. An advantage of the transtriceps injection is that contrast leakage through the posterior needle tract does not interfere with evaluation of the lateral structures.
Seismic Design of a Single Bored Tunnel: Longitudinal Deformations and Seismic Joints
NASA Astrophysics Data System (ADS)
Oh, J.; Moon, T.
2018-03-01
The large diameter bored tunnel passing through rock and alluvial deposits subjected to seismic loading is analyzed for estimating longitudinal deformations and member forces on the segmental tunnel liners. The project site has challenges including high hydrostatic pressure, variable ground profile and high seismic loading. To ensure the safety of segmental tunnel liner from the seismic demands, the performance-based two-level design earthquake approach, Functional Evaluation Earthquake and Safety Evaluation Earthquake, has been adopted. The longitudinal tunnel and ground response seismic analyses are performed using a three-dimensional quasi-static linear elastic and nonlinear elastic discrete beam-spring elements to represent segmental liner and ground spring, respectively. Three components (longitudinal, transverse and vertical) of free-field ground displacement-time histories evaluated from site response analyses considering wave passage effects have been applied at the end support of the strain-compatible ground springs. The result of the longitudinal seismic analyses suggests that seismic joint for the mitigation measure requiring the design deflection capacity of 5-7.5 cm is to be furnished at the transition zone between hard and soft ground condition where the maximum member forces on the segmental liner (i.e., axial, shear forces and bending moments) are induced. The paper illustrates how detailed numerical analyses can be practically applied to evaluate the axial and curvature deformations along the tunnel alignment under difficult ground conditions and to provide the seismic joints at proper locations to effectively reduce the seismic demands below the allowable levels.
Shirazi, Zahra Rojhani; Shafaee, Razieh; Abbasi, Leila
2014-10-01
To study the effects of transcutaneous electrical nerve stimulation (TENS) on joint position sense (JPS) in knee osteoarthritis (OA) subjects. Thirty subjects with knee OA (40-60 years old) using non-random sampling participated in this study. In order to evaluate the absolute error of repositioning of the knee joint, Qualysis Track Manager system was used and sensory electrical stimulation was applied through the TENS device. The mean errors in repositioning of the joint, in two position of the knee joint with 20 and 60 degree angle, after applying the TENS was significantly decreased (p < 0.05). Application of TENS in subjects with knee OA could improve JPS in these subjects.
Norris, James A; Stabile, Kathryne J; Jinnah, Riyaz H
2008-01-01
Tribology is the study of friction, wear, lubrication mechanisms, and their interrelationships. Biotribiology focuses on understanding diarthrodial joints and has been a branch of tribology since 1973. Since then, biotribology has played a prominent role in the evaluation and development of joint prostheses, contributing to reduced wear and increased longevity. Total joint replacements are now common for arthritic patients and are also used in treating a variety of other orthopaedic conditions. For this reason, a complete understanding of the joint lubrication and microstructure that exists in nature is crucial. A subfield of biotribology, biomimetic tribology, has been formed with this goal in mind. This review covers the basic concepts of tribology, provides a brief historical perspective on joint prostheses, and presents the application of tribology in understanding diarthrodial and prosthetic joints.
Umapathy, Hema; Bennell, Kim; Dickson, Chris; Dobson, Fiona; Fransen, Marlene; Jones, Graeme; Hunter, David J
2015-07-07
Despite the availability of evidence-based guidelines for conservative treatment of osteoarthritis (OA), management is often confined to the use of analgesics and waiting for eventual total joint replacement. This suggests a gap in knowledge for persons with OA regarding the many different treatments available to them. Our objective was to evaluate outcomes after usage of a Web-based resource called My Joint Pain that contains tailored, evidence-based information and tools aimed to improve self-management of OA on self-management and change in knowledge. A quasi-experimental design was used to evaluate the My Joint Pain website intervention over a 12-month period. The intervention provided participants with general and user-specific information, monthly assessments with validated instruments, and progress-tracking tools. A nationwide convenience sample of 195 participants with self-assessed hip and/or knee OA completed both baseline and 12-month questionnaires (users: n=104; nonusers: n=91). The primary outcome measure was the Health Evaluation Impact Questionnaire (heiQ) to evaluate 8 different domains (health-directed activity, positive and active engagement in life, emotional distress, self-monitoring and insight, constructive attitudes and approaches, skill and technique acquisition, social integration and support, health service navigation) and the secondary outcome measure was the 17-item Osteoarthritis Quality Indicator (OAQI) questionnaire to evaluate the change in appropriateness of care received by participants. Independent t tests were used to compare changes between groups for the heiQ and chi-square tests to identify changes within and between groups from baseline to 12 months for each OAQI item. Baseline demographics between groups were similar for gender (152/195, 77.9% female), age (mean 60, SD 9 years) and body mass index (mean 31.1, SD 6.8 kg/m(2)). With the exception of health service navigation, mean effect sizes from all other heiQ domains showed a positive trend for My Joint Pain users compared to the nonusers, although the differences between groups did not reach statistical significance. Within-group changes also showed improvements among the users of the My Joint Pain website for self-management (absolute change score=15%, P=.03), lifestyle (absolute change score=16%, P=.02), and physical activity (absolute change score=11%, P=.04), with no significant improvements for the nonusers. Following 12 months of exposure to the website, there were significant improvements for users compared to nonusers in self-management (absolute change score 15% vs 2%, P=.001) and weight reduction (absolute change scores 3% vs -6%, P=.03) measured on the OAQI. The My Joint Pain Web resource does not significantly improve overall heiQ, but does improve other important aspects of quality of care in people with hip and/or knee OA. Further work is required to improve engagement with the website and the quality of information delivered in order to provide a greater impact.
Chrysler Upset Protrusion Joining Techniques for Joining Dissimilar Metals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Logan, Stephen
The project goal was to develop and demonstrate a robust, cost effective, and versatile joining technique, known as Upset Protrusion Joining (UPJ), for joining challenging dissimilar metal com-binations, especially those where one of the metals is a die cast magnesium (Mg) component. Since two of the key obstacles preventing more widespread use of light metals (especially in high volume automotive applications) are 1) a lack of robust joining techniques and 2) susceptibility to galvanic corrosion, and since the majority of the joint combinations evaluated in this project include die cast Mg (the lightest structural metal) as one of the twomore » materials being joined, and since die casting is the most common and cost effective process for producing Mg components, then successful project completion provides a key enabler to high volume application of lightweight materials, thus potentially leading to reduced costs, and encouraging implementation of lightweight multi-material vehicles for significant reductions in energy consumption and reduced greenhouse gas emissions. Eco-nomic benefits to end-use consumers are achieved primarily via the reduction in fuel consumption. Unlike currently available commercial processes, the UPJ process relies on a very robust mechanical joint rather than intermetallic bonding, so the more cathodic material can be coated prior to joining, thus creating a robust isolation against galvanic attack on the more anodic material. Additionally, since the UPJ protrusion is going through a hole that can be pre-drilled or pre-punched prior to coating, the UPJ process is less likely to damage the coating when the joint is being made. Further-more, since there is no additional cathodic material (such as a steel fastener) used to create the joint, there is no joining induced galvanic activity beyond that of the two parent materials. In accordance with its originally proposed plan, this project has successfully developed process variants of UPJ to enable joining of Mg die castings to aluminum (Al) and steel sheet components of various thicknesses, strengths and coating configurations. While most development focused on the simpler round boss version of the process, an additional phase of the work focused on devel-opment of an oval boss version to support applications with narrow flanges, while yet another vari-ant of the process, known as Upset Cast Riveting (UCR), was developed and evaluated for joining mixed metals that may not necessarily include Mg or Al die cast components. Although each varia-tion posed unique challenges described later in the report, all variations were successfully produced and evaluated, and each could be further developed for specific types of commercial applications. In this project, UPJ performed favorably against the benchmark self-pierce riveting (SPR) process in Mg AM60B to Al 6013 combinations although significant corrosion challenges were observed in both processes, especially for the bare Mg to bare Al configurations. Additional challenges were observed in joining Mg to steel with the UPJ process (SPR was not evaluated for this combination as it was not considered viable). To pass FCA’s specified corrosion tests with Mg/steel combina-tions, new steel treatments were evaluated, as well as adhesives and sealed edges. These showed significant improvement. In general, UPJ performed very well in Mg to Al 6016 combinations, even in corrosion evaluation of the bare Mg to bare Al configuration (again, SPR was not evaluated for this material combination as the 1.1 mm thick Al6016 sheet thickness was considered too thin for the SPR process). The improvement in corrosion performance of the Mg to Al 6016 combina-tion over the Mg to Al 6013 combination was thought to be a result of the lower copper content in the Al 6016 alloy. Oval boss joints showed substantial improvement in all joint strength criteria compared to 8.0-mm diameter round boss joints but were not evaluated for corrosion performance. The improved joint strength is likely a result of larger shear area. Cosmetic corrosion performance of all test assemblies (UPJ, UCR and SPR) was a challenge due to exposed edges and crevices al-lowing undercutting of the coatings. In real world component applications, the exposed edges, so prevalent on the joining test coupons, would be less prevalent and easier to protect.« less
Joining of polypropylene/polypropylene and glass fiber reinforced polypropylene composites
NASA Astrophysics Data System (ADS)
Zhang, Jianguang
Joining behavior of polypropylene (PP) to PP and long glass fiber reinforced polypropylene (LFT) to LFT were investigated. Adhesive bonding was used to join PP/PP. Both adhesive bonding and ultrasonic welding were used to join LFT/LFT. Single-lap shear testing and low velocity impact (LVI) testing were used to evaluate the performance of bonded structures. The two-part acrylic adhesive DP8005 was determined to be the best among the three adhesive candidates, which was attributed to its low surface energy. The impact resistance of LFT/LFT joints, normalized with respect to thickness, was higher than that of PP/PP joints because of higher stiffness of LFT/LFT joints. The stress states in the adhesive layer of adhesively bonded structures were analyzed using ANSYS and LS-DYNA to simulate the single-lap shear testing and LVI testing, respectively. The shear and peel stresses peaked at the edges of the adhesive layer. Compared to LFT/LFT joints, higher peel stress occurred in the adhesive layer in the PP/PP joints in tension. Impact response of adhesively bonded structures as evaluated by LS-DYNA showed good agreement with the experimental results. The effect of weld time and weld pressure on the shear strength of ultrasonically welded LFT/LFT was evaluated. With higher weld pressure, less time was required to obtain a complete weld. At longer weld times, lower weld pressure was required. From the 15 weld conditions studied, a weld map was obtained that provides conditions to achieve a complete weld. Nanoindentation was used to evaluate the effect of ultrasonic weld on the modulus and hardness of the PP matrix. Modulus and hardness of the PP matrix were slightly decreased by ultrasonic welding possibly due to the decrease in the molecular weight. The temperature profile in LFT/LFT in the transverse direction during ultrasonic welding was analyzed by two ANSYS-based thermal models: (a) one in which heat generated by interfacial friction was treated as a heat flux and (b) one in which heat was generated in a thin slab at the interface. The weld map obtained from the thin slab model was closer to the one obtained experimentally.
The Treatment of Joint Pain with Intra-articular Pulsed Radiofrequency.
Schianchi, Pietro M; Sluijter, Menno E; Balogh, Susan E
2013-09-01
The intra-articular (IA) application of pulsed radiofrequency (PRF) for pain in small and large joints represents a recent development that has proven to be effective in many cases. We performed a retrospective study of 89 such procedures in 57 consecutive patients with chronic articular pain. The aim of this retrospective study is to evaluate the effectiveness of intraarticular PRF in a group of 57 consecutive patients with chronic joint pain. Patients with intractable joint pain for more than 6 months were treated with IA PRF 40-45V for 10-15 min in small joints and 60V for 15 min in large joints using fluoroscopic confirmation of correct needle position. A total of 28 shoulders, 40 knees, 10 trapezio-metacarpal, and 11 first metatarso-phalangeal joints were treated. Results were evaluated at 1, 2, and 5 months. The procedure was repeated after 1 month in 10 patients with initial suboptimal results. Success was defined as a reduction of pain score by at least 50%. All groups showed significant reductions in pain scores at all three follow-up visits. Success rates were higher in small joints (90% and 82%, respectively) than large ones (64% and 60%, respectively). Interestingly, IA PRF was successful in 6 out of 10 patients who had undergone previous surgery, including 3 with prosthetic joint replacement and in 6 of the 10 repeated procedures. There were no significant adverse effects or complications. IA PRF induced significant pain relief of long duration in a majority of our patients with joint pain. The exact mechanism is unclear, but may be related to the exposure of immune cells to low-strength RF fields, inducing an anti-inflammatory effect. The success rate appears to be highest in small joints. We recommend additional research including control groups to further investigate and clarify this method; our data suggest that it may represent a useful modality in the treatment of arthrogenic pain.
Mehanical Properties of Electron Beam Welded Joints in Thick Gage CA6NM Stainless Steel
NASA Astrophysics Data System (ADS)
Sarafan, Sheida; Wanjara, Priti; Gholipour, Javad; Champliaud, Henri; Mathieu, Louis
2017-10-01
Design of hydroelectric turbine components requires high integrity welds (without detectable volumetric defects) in heavy gage sections of stainless steel materials, such as ASTM A743 grade CA6NM—a low carbon 13% Cr-4% Ni martensitic stainless steel that is manufactured in cast form. In this work, 90-mm-thick plates of CA6NM were joined using a single-pass autogenous electron beam (EB) welding process and the mechanical properties were evaluated in the as-welded condition to characterize the performance of the joints. The static tensile properties that were evaluated in two directions—transverse and longitudinal to the EB weld seam—demonstrated conformance of the joints with the requirements of the ASME Section IX standard. The Charpy impact energies of the EB welds—measured at -18 °C on samples with V-notch roots located in the fusion and heat-affected zones—met the minimum requirements of 27 J specified in ASME Section VIII standard. In addition, bend tests that were conducted on the entire weld cross section displayed no discontinuities on the tension side of the bent joints. Hence, the developed EB welding process was demonstrated to render high-performance joints and promises key advantages for industrialization, such as cost savings through reductions in consumable material, production time and labor intensity.
An evaluation of the lap-shear test for Sn-rich solder/Cu couples: Experiments and simulation
NASA Astrophysics Data System (ADS)
Chawla, N.; Shen, Y.-L.; Deng, X.; Ege, E. S.
2004-12-01
The lap-shear technique is commonly used to evaluate the shear, creep, and thermal fatigue behavior of solder joints. We have conducted a parametric experimental and modeling study, on the effect of testing and geometrical parameters on solder/copper joint response in lap-shear. It was shown that the farfield applied strain is quite different from the actual solder strain (measured optically). Subtraction of the deformation of the Cu substrate provides a reasonable approximation of the solder strain in the elastic regime, but not in the plastic regime. Solder joint thickness has a profound effect on joint response. The solder response moves progressively closer to “true” shear response with increasing joint thickness. Numerical modeling using finite-element analyses were performed to rationalize the experimental findings. The same lap-shear configuration was used in the simulation. The input response for solder was based on the experimental tensile test result on bulk specimens. The calculated shear response, using both the commonly adopted far-field measure and the actual shear strain in solder, was found to be consistent with the trends observed in the lap-shear experiments. The geometric features were further explored to provide physical insight into the problem. Deformation of the substrate was found to greatly influence the shear behavior of the solder.
Joint hyperlaxity prevents relapses in clubfeet treated by Ponseti method-preliminary results.
Cosma, Dan Ionuţ; Corbu, Andrei; Nistor, Dan Viorel; Todor, Adrian; Valeanu, Madalina; Morcuende, Jose; Man, Sorin
2018-05-07
The aim of the study was to evaluate the role of joint hyperlaxity (by Beighton score) as a protective factor for clubfoot relapse. Patients with idiopathic clubfoot treated with the Ponseti method between January 2004 and December 2012, without other congenital foot deformity, and not previously treated by open surgery were included in either the Relapse group (n = 23) if it was a clubfoot relapse or the Control group (n = 19) if no relapse was noted. Joint laxity was evaluated using the Beighton score at the latest follow-up against the Normal group (n = 22, children matched by sex and age without clubfoot deformity). We found a significantly higher joint laxity in the Control group (4.58, 95% confidence interval [CI]: 2.1-7.06) as compared to the Relapse (3.17, 95% CI: 1.53-4.81, p = 0.032) and Normal (3.14, 95% CI: 1.78-4.5, p = 0.03) groups. The univariate logistic regression showed a 5.28-times increase in the risk of relapse for a Beighton score lower than 4/9 points (odds ratio = 5.28; 95% CI = 1.29-21.5; p = 0.018). Joint hyperlaxity could be a protective factor for clubfoot relapse.
NASA Astrophysics Data System (ADS)
Monteiro Santos, Fernando A.; Afonso, António R. Andrade; Dupis, André
2007-03-01
Audio-magnetotelluric (AMT) and resistivity (dc) surveys are often used in environmental, hydrological and geothermal evaluation. The separate interpretation of those geophysical data sets assuming two-dimensional models frequently produces ambiguous results. The joint inversion of AMT and dc data is advocated by several authors as an efficient method for reducing the ambiguity inherent to each of those methods. This paper presents results obtained from the two-dimensional joint inversion of dipole-dipole and scalar AMT data acquired in a low enthalpy geothermal field situated in a graben. The joint inverted models show a better definition of shallow and deep structures. The results show that the extension of the benefits using joint inversion depends on the number and spacing of the AMT sites. The models obtained from experimental data display a low resistivity zone (<20 Ω m) in the central part of the graben that was correlated with the geothermal reservoir. The resistivity distribution models were used to estimate the distribution of the porosity in the geothermal reservoir applying two different approaches and considering the clay minerals effect. The results suggest that the maximum porosity of the reservoir is not uniform and might be in the range of 12% to 24%.
Effect of Gold on the Microstructural Evolution and Integrity of a Sintered Silver Joint
NASA Astrophysics Data System (ADS)
Muralidharan, Govindarajan; Leonard, Donovan N.; Meyer, Harry M.
2017-07-01
There is a need for next-generation, high-performance power electronic packages and systems employing wide-bandgap devices to operate at high temperatures in automotive and electric grid applications. Sintered silver joints are currently being evaluated as an alternative to Pb-free solder joints. Of particular interest is the development of joints based on silver paste consisting of nano- or micron-scale particles that can be processed without application of external pressure. The microstructural evolution at the interface of a pressureless-sintered silver joint formed between a SiC die with Ti/Ni/Au metallization and an active metal brazed (AMB) substrate with Ag metallization at 250°C has been evaluated using scanning electron microscopy (SEM), x-ray microanalysis, and x-ray photoelectron spectroscopy (XPS). Results from focused ion beam (FIB) cross-sections show that, during sintering, pores in the sintered region near to the Au layer tend to be narrow and elongated with long axis oriented parallel to the interface. Further densification results in formation of many small, relatively equiaxed pores aligned parallel to the interface, creating a path for easy crack propagation. X-ray microanalysis results confirm interdiffusion between Au and Ag and that a region with poor mechanical strength is formed at the edge of this region of interdiffusion.
On-spot rheumatology consultations in a multilevel geriatric hospital.
Lubart, Emily; Leibovitz, Arthur; Shapir, Vadim; Segal, Refael
2014-01-01
Musculoskeletal and joint disorders are extremely common in the elderly. They directly affect mobility, gait stability, quality of life, and independence. To assess the nature of joint problems encountered in a geriatric inpatient population and evaluate the contribution of a rheumatologist. We reviewed the rheumatology consultation records that were conducted in a geriatric medical center over a 10 year period. A total of 474 consultations were held; most of these patients (86%) were hospitalized in the acute geriatric departments, 10% in the rehabilitation ward and 4% in the long-term care wards. Some patients were seen more than once. A rheumatologic joint problem was the main reason for hospitalization in 53% of these patients. Monoarthritis was the most frequent complaint (50%), followed by pauciarticular arthritis (two to five joints) in 30% of patients. Arthrocentesis, diagnostic and therapeutic, was performed in 225 patients, most of them in knee joints (81%). The most frequent diagnosis was osteoarthritis with acute exacerbation (28%), followed by gout (18%), pseudo-gout (9%) and rheumatoid arthritis (9%). In 86 cases (18%) the diagnosis was a non-specific rheumatologic problem: arthralgia, nonspecific generalized pain, or fibromyalgia. Prompt and appropriate evaluation, as well as arthrocentesis and treatment initiation, including local injections, were made possible by the presence of an in-house rheumatologist.
Olsen-Bergem, H; Bjørnland, T
2014-08-01
The purpose of this study was to evaluate the effects of intra-articular temporomandibular joint (TMJ) treatment in patients with juvenile idiopathic arthritis (JIA). The inclusion criteria were met by 21 patients (38 joints). Joints were randomly selected for either arthrocentesis alone (n=17) or arthrocentesis with the additional use of triamcinolone hexacetonide (n=21) using a closed single-needle system. Measurements of pain and function were performed at baseline and at follow-up after 3 and 8 months. Pain on opening and lateral excursion improved significantly after injections. Pain decreased significantly from baseline to first and second control on a visual analogue scale (VAS) for overall pain (49-18-8) and overall function (41-19-4). Significant improvement was recorded for pain on palpation of muscles and joints. There was no statistically significant difference between the treatment modalities, with or without glucocorticoid injection. Arthrocentesis in the TMJ treatment of patients with JIA may be beneficial and steroids had no additional effect. Further studies are needed to evaluate the long-term effects on the TMJ structures and on condylar growth from arthrocentesis and intra-articular steroid injections. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Evaluation of the three-dimensional bony coverage before and after rotational acetabular osteotomy.
Tanaka, Takeyuki; Moro, Toru; Takatori, Yoshio; Oshima, Hirofumi; Ito, Hideya; Sugita, Naohiko; Mitsuishi, Mamoru; Tanaka, Sakae
2018-02-26
Rotational acetabular osteotomy is a type of pelvic osteotomy that involves rotation of the acetabular bone to improve the bony coverage of the femoral head for patients with acetabular dysplasia. Favourable post-operative long-term outcomes have been reported in previous studies. However, there is a paucity of published data regarding three-dimensional bony coverage. The present study investigated the three-dimensional bony coverage of the acetabulum covering the femoral head in hips before and after rotational acetabular osteotomy and in normal hips. The computed tomography data of 40 hip joints (12 joints before and after rotational acetabular osteotomy; 16 normal joints) were analyzed. The three-dimensional bony coverage of each joint was evaluated using original software. The post-operative bony coverage improved significantly compared with pre-operative values. In particular, the anterolateral aspect of the acetabulum tended to be dysplastic in patients with acetabular dysplasia compared to those with normal hip joints. However, greater bony coverage at the anterolateral aspect was obtained after rotational acetabular osteotomy. Meanwhile, the results of the present study may indicate that the bony coverage in the anterior aspect may be excessive. Three-dimensional analysis indicated that rotational acetabular osteotomy achieved favorable bony coverage. Further investigations are necessary to determine the ideal bony coverage after rotational acetabular osteotomy.
Niska, Jared A.; Shahbazian, Jonathan H.; Ramos, Romela Irene; Francis, Kevin P.; Bernthal, Nicholas M.
2013-01-01
Treatment of prosthetic joint infections often involves a two-stage exchange, with implant removal and antibiotic spacer placement followed by systemic antibiotic therapy and delayed reimplantation. However, if antibiotic therapy can be improved, one-stage exchange or implant retention may be more feasible, thereby decreasing morbidity and preserving function. In this study, a mouse model of prosthetic joint infection was used in which Staphylococcus aureus was inoculated into a knee joint containing a surgically placed metallic implant extending from the femur. This model was used to evaluate whether combination therapy of vancomycin plus rifampin has increased efficacy compared with vancomycin alone against these infections. On postoperative day 7, vancomycin with or without rifampin was administered for 6 weeks with implant retention. In vivo bioluminescence imaging, ex vivo CFU enumeration, X-ray imaging, and histologic analysis were carried out. We found that there was a marked therapeutic benefit when vancomycin was combined with rifampin compared with vancomycin alone. Taken together, our results suggest that the mouse model used could serve as a valuable in vivo preclinical model system to evaluate and compare efficacies of antibiotics and combinatory therapy for prosthetic joint infections before more extensive studies are carried out in human subjects. PMID:23917317
Long-term functional outcome after surgical repair of cranial cruciate ligament disease in dogs.
Mölsä, Sari H; Hyytiäinen, Heli K; Hielm-Björkman, Anna K; Laitinen-Vapaavuori, Outi M
2014-11-19
Cranial cruciate ligament (CCL) rupture is a very common cause of pelvic limb lameness in dogs. Few studies, using objective and validated outcome evaluation methods, have been published to evaluate long-term (>1 year) outcome after CCL repair. A group of 47 dogs with CCL rupture treated with intracapsular, extracapsular, and osteotomy techniques, and 21 healthy control dogs were enrolled in this study. To evaluate long-term surgical outcome, at a minimum of 1.5 years after unilateral CCL surgery, force plate, orthopedic, radiographic, and physiotherapeutic examinations, including evaluation of active range of motion (AROM), symmetry of thrust from the ground, symmetry of muscle mass, and static weight bearing (SWB) of pelvic limbs, and goniometry of the stifle and tarsal joints, were done. At a mean of 2.8 ± 0.9 years after surgery, no significant differences were found in average ground reaction forces or SWB between the surgically treated and control dog limbs, when dogs with no other orthopedic findings were included (n = 21). However, in surgically treated limbs, approximately 30% of the dogs had decreased static or dynamic weight bearing when symmetry of weight bearing was evaluated, 40-50% of dogs showed limitations of AROM in sitting position, and two-thirds of dogs had weakness in thrust from the ground. The stifle joint extension angles were lower (P <0.001) and flexion angles higher (P <0.001) in surgically treated than in contralateral joints, when dogs with no contralateral stifle problems were included (n = 33). In dogs treated using the intracapsular technique, the distribution percentage per limb of peak vertical force (DPVF) in surgically treated limbs was significantly lower than in dogs treated with osteotomy techniques (P =0.044). The average long-term dynamic and static weight bearing of the surgically treated limbs returned to the level of healthy limbs. However, extension and flexion angles of the surgically treated stifles remained inferior to healthy joints, and impairment of AROM and weakness in thrust from the ground in the surgically treated limbs were frequently present. Ground reaction forces may be inadequate as a sole method for assessing functional outcome after cranial cruciate ligament repair.