Does use of a PACS increase the number of images per study? A case study in ultrasound.
Horii, Steven; Nisenbaum, Harvey; Farn, James; Coleman, Beverly; Rowling, Susan; Langer, Jill; Jacobs, Jill; Arger, Peter; Pinheiro, Lisa; Klein, Wendy; Reber, Michele; Iyoob, Christopher
2002-03-01
The purpose of this study was to determine if the use of a picture archiving and communications system (PACS) in ultrasonography increased the number of images acquired per examination. The hypothesis that such an increase does occur was based on anecdotal information; this study sought to test the hypothesis. A random sample of all ultrasound examination types was drawn from the period 1998 through 1999. The ultrasound PACS in use (ACCESS; Kodak Health Information Systems, Dallas, TX) records the number of grayscale and color images saved as part of each study. Each examination in the sample was checked in the ultrasound PACS database,.and the number of grayscale and color images was recorded. The comparison film-based sample was drawn from the period 1994 through 1995. The number of examinations of each type selected was based on the overall statistics of the section; that is, the sample was designed to represent the approximate frequency with which the various examination types are done. For film-based image counts, the jackets were retrieved, and the number of grayscale and color images were counted. The number of images obtained per examination (for most examinations) in ultrasound increased with PACS use. This was more evident with some examination types (eg, pelvis). This result, however, has to be examined for possible systematic biases because ultrasound practice has changed over the time since the authors stopped using film routinely. The use of PACS in ultrasonography was not associated with an increase in the number of images per examination based solely on the use of PACS, with the exception of neonatal head studies. Increases in the number of images per study was otherwise associated with examinations for which changes in protocols resulted in the increased image counts.
Factors Contributing to University Image: The Postgraduate Students' Points of View
ERIC Educational Resources Information Center
Aghaz, Asal; Hashemi, Amin; Atashgah, Maryam S. Sharifi
2015-01-01
Despite several studies having been conducted to examine organizational image from a business perspective, there has not been adequate research in the area of perceived image in nonprofit organizations such as universities. Thus, the purpose of this study was to examine the factors contributing to university image, from the postgraduate students'…
Allen, Bibb; Carrol, L Van; Hughes, Danny R; Hemingway, Jennifer; Duszak, Richard; Rosenkrantz, Andrew B
2017-04-01
To study differences in imaging utilization downstream to initial emergency department (ED) ultrasound examinations interpreted by radiologists versus nonradiologists. Using 5% Medicare Research Identifiable Files from 2009 to 2014, we identified episodes where the place of service was "emergency room hospital" and the patient also underwent an ultrasound examination. We determined whether the initial ultrasound was interpreted by a radiologist or nonradiologist and then summed all additional imaging events occurring within 7, 14, and 30 days of each initial ED ultrasound. For each year and each study window, we calculated the mean number of downstream imaging procedures by specialty group. Of 200,357 ED ultrasound events, 163,569 (81.6%) were interpreted by radiologists and 36,788 (18.4%) by nonradiologists. Across all study years, ED patients undergoing ultrasound examinations interpreted by nonradiologists underwent 1.08, 1.22, and 1.34 additional diagnostic imaging studies at 7, 14, and 30 days, respectively (P < .01) compared with when the initial ultrasound examination was interpreted by a radiologist. From 2010 to 2014, the volume of downstream imaging for both radiologists and nonradiologists significantly decreased, with each year resulting in 0.08 fewer imaging examinations (P < .001) 14 days after the ED ultrasound event. Despite that decline, differences in downstream imaging between radiologists and nonradiologists persisted over time. Downstream imaging after an initial ED ultrasound is significantly reduced when the ultrasound examination is interpreted by a radiologist rather than a nonradiologist. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
The Effect of Images on Item Statistics in Multiple Choice Anatomy Examinations
ERIC Educational Resources Information Center
Notebaert, Andrew J.
2017-01-01
Although multiple choice examinations are often used to test anatomical knowledge, these often forgo the use of images in favor of text-based questions and answers. Because anatomy is reliant on visual resources, examinations using images should be used when appropriate. This study was a retrospective analysis of examination items that were text…
Gurwin, Jaclyn; Tomlinson, Lauren A; Quinn, Graham E; Ying, Gui-Shuang; Baumritter, Agnieshka; Binenbaum, Gil
2017-01-05
The Telemedicine Approaches to Evaluating Acute-Phase Retinopathy of Prematurity (e-ROP) Study telemedicine system of remote fundus image grading and The Children's Hospital of Philadelphia Retinopathy of Prematurity (CHOP-ROP) postnatal weight gain predictive model are 2 approaches for improving ROP screening efficiency. Current screening has low specificity for severe ROP. To describe a tiered approach to ROP screening (TARP) for identifying children who develop severe ROP using telemedicine and a predictive model synergistically. This investigation was a post hoc analysis of a cohort in the e-ROP Study (a multicenter prospective telemedicine study) and the Postnatal Growth and Retinopathy of Prematurity (G-ROP) Study (a multicenter retrospective cohort study). The setting was neonatal intensive care units at The Children's Hospital of Philadelphia and the Hospital of the University of Pennsylvania. Participants in the e-ROP Study were premature infants with a birth weight less than 1251 g and a known ROP outcome enrolled between May 25, 2011, and October 31, 2013. The G-ROP Study enrolled all infants undergoing ROP examinations with a known ROP outcome who were born between January 1, 2006, and December 31, 2011. The mean outcomes were the sensitivity for type 1 ROP, reductions in infants requiring imaging or examinations, numbers of imaging sessions and examinations, and total clinical encounters (imaging sessions and examinations combined). The following 4 screening approaches were evaluated: ROUTINE (only diagnostic examinations by an ophthalmologist), CHOP-ROP (birth weight and gestational age, with weekly weight gain initiating examinations when the risk cut point is surpassed), e-ROP IMAGING (trained reader grading of type 1 or 2 ROP initiates diagnostic examinations), and TARP (CHOP-ROP alarm initiates imaging, and imaging finding of severe ROP initiates diagnostic examinations). A total of 242 infants were included in the study, with a median birth weight of 858 g (range, 690-1035 g). The median gestational age was 27 weeks (range, 25-29 weeks). Fifty-one percent (124 of 242) were female, and 49% (118 of 242) were male. The race/ethnicity was 27.3% (66 of 242) white, 56.2% (136 of 242) black, 2.1% (5 of 242) Native American, 1.7% (4 of 242) Asian, and 12.8% (31 of 242) other. The sensitivity for detecting type 1 ROP (32 infants) was 100% (95% CI, 89.3%-100%) with each approach. With ROUTINE, 242 infants had 877 examinations; with CHOP-ROP, 184 infants had 730 examinations; with e-ROP IMAGING, 242 infants had 532 imaging sessions, and 94 infants had 345 examinations (877 patient encounters); and with TARP, 182 infants had 412 imaging sessions, and 87 infants had 322 examinations (734 patient encounters). The tiered approach to ROP screening was associated with a reduced number of examinations and imaging sessions compared with the other approaches. Applying a postnatal growth model and telemedicine system in a tiered approach may reduce the number of clinical ROP interventions more than either approach alone.
Socializing Young Readers: A Content Analysis of Body Size Images in Caldecott Medal Winners
ERIC Educational Resources Information Center
Wedwick, Linda; Latham, Nancy
2013-01-01
Many studies have examined gender issues in children's literature, but a review of the literature reveals that few studies have examined the instances of fatness in the images. Studying the fat representation in the images of children's literature is important because exposure to a variety of body types may slow the rate of children's body…
Cocaine, Appetitive Memory and Neural Connectivity
Ray, Suchismita
2013-01-01
This review examines existing cognitive experimental and brain imaging research related to cocaine addiction. In section 1, previous studies that have examined cognitive processes, such as implicit and explicit memory processes in cocaine users are reported. Next, in section 2, brain imaging studies are reported that have used chronic users of cocaine as study participants. In section 3, several conclusions are drawn. They are: (a) in cognitive experimental literature, no study has examined both implicit and explicit memory processes involving cocaine related visual information in the same cocaine user, (b) neural mechanisms underlying implicit and explicit memory processes for cocaine-related visual cues have not been directly investigated in cocaine users in the imaging literature, and (c) none of the previous imaging studies has examined connectivity between the memory system and craving system in the brain of chronic users of cocaine. Finally, future directions in the field of cocaine addiction are suggested. PMID:25009766
What Geoscience Experts and Novices Look At, and What They See, When Viewing Data Visualizations
ERIC Educational Resources Information Center
Kastens, Kim A.; Shipley, Thomas F.; Boone, Alexander P.; Straccia, Frances
2016-01-01
This study examines how geoscience experts and novices make meaning from an iconic type of data visualization: shaded relief images of bathymetry and topography. Participants examined, described, and interpreted a global image, two high-resolution seafloor images, and 2 high-resolution continental images, while having their gaze direction…
A Comparison of Strategies for Retinopathy of Prematurity Detection
Prosser, Lisa A.; Wade, Kelly C.; Repka, Michael X.; Ying, Gui-shuang; Baumritter, Agnieshka; Quinn, Graham E.
2016-01-01
BACKGROUND AND OBJECTIVES: Delayed detection of type 1 retinopathy of prematurity (ROP) can lead to permanent visual impairment. Providing ROP examinations is challenging because of the limited ophthalmology workforce. This study compares digital imaging–based ROP detection strategies versus serial ROP examinations. METHODS: We conducted an individual-level microsimulation studyof a hypothetical cohort of 650 infants with gestational age from 23 to 30 weeks. Infants were evaluated by using strategies based on indirect ophthalmoscopy or digital imaging beginning at 32 weeks’ postmenstrual age (PMA) and continuing to discharge, transfer, or 40 weeks’ PMA. ROP status and the accuracy of digital imaging were based on the e-ROP (Telemedicine Approaches to Evaluating Acute-Phase ROP) study, which enrolled high-risk infants. RESULTS: Within the hypothetical NICU, the strategy of ROP examinations identified an average of 45.8 cases of type 1 ROP by discharge, transfer, or 40 weeks’ PMA, and another 1.9 cases were included in the group of infants recommended to have later follow-up. Digital imaging with an ROP examination at discharge identified all 47.7 cases of type 1 ROP. On average, the ROP examination–only strategy required 1745.7 ROP examinations, whereas digital imaging with a discharge examination required 1065.5 ROP examinations and 1786.2 digital imaging sessions. CONCLUSIONS: Although digital imaging decreased the number of ROP examinations per infant, there was an increase in the total number of interventions (ie, ROP examinations and imaging sessions). Providing an ROP examination at the time of NICU discharge can significantly reduce the number of infants who require follow-up. PMID:26672022
Patient-specific lean body mass can be estimated from limited-coverage computed tomography images.
Devriese, Joke; Beels, Laurence; Maes, Alex; van de Wiele, Christophe; Pottel, Hans
2018-06-01
In PET/CT, quantitative evaluation of tumour metabolic activity is possible through standardized uptake values, usually normalized for body weight (BW) or lean body mass (LBM). Patient-specific LBM can be estimated from whole-body (WB) CT images. As most clinical indications only warrant PET/CT examinations covering head to midthigh, the aim of this study was to develop a simple and reliable method to estimate LBM from limited-coverage (LC) CT images and test its validity. Head-to-toe PET/CT examinations were retrospectively retrieved and semiautomatically segmented into tissue types based on thresholding of CT Hounsfield units. LC was obtained by omitting image slices. Image segmentation was validated on the WB CT examinations by comparing CT-estimated BW with actual BW, and LBM estimated from LC images were compared with LBM estimated from WB images. A direct method and an indirect method were developed and validated on an independent data set. Comparing LBM estimated from LC examinations with estimates from WB examinations (LBMWB) showed a significant but limited bias of 1.2 kg (direct method) and nonsignificant bias of 0.05 kg (indirect method). This study demonstrates that LBM can be estimated from LC CT images with no significant difference from LBMWB.
Intraoperative CT in the assessment of posterior wall acetabular fracture stability.
Cunningham, Brian; Jackson, Kelly; Ortega, Gil
2014-04-01
Posterior wall acetabular fractures that involve 10% to 40% of the posterior wall may or may not require an open reduction and internal fixation. Dynamic stress examination of the acetabular fracture under fluoroscopy has been used as an intraoperative method to assess joint stability. The aim of this study was to demonstrate the value of intraoperative ISO computed tomography (CT) examination using the Siemens ISO-C imaging system (Siemens Corp, Malvern, Pennsylvania) in the assessment of posterior wall acetabular fracture stability during stress examination under anesthesia. In 5 posterior wall acetabular fractures, standard fluoroscopic images (including anteroposterior pelvis and Judet radiographs) with dynamic stress examinations were compared with the ISO-C CT imaging system to assess posterior wall fracture stability during stress examination. After review of standard intraoperative fluoroscopic images under dynamic stress examination, all 5 cases appeared to demonstrate posterior wall stability; however, when the intraoperative images from the ISO-C CT imaging system demonstrated that 1 case showed fracture instability of the posterior wall segment during stress examination, open reduction and internal fixation was performed. The use of intraoperative ISO CT imaging has shown an initial improvement in the surgeon's ability to assess the intraoperative stability of posterior wall acetabular fractures during stress examination when compared with standard fluoroscopic images. Copyright 2014, SLACK Incorporated.
The complexity of body image following bariatric surgery: a systematic review of the literature.
Ivezaj, V; Grilo, C M
2018-06-13
Poor body image is common among individuals seeking bariatric surgery and is associated with adverse psychosocial sequelae. Following massive weight loss secondary to bariatric surgery, many individuals experience excess skin and associated concerns, leading to subsequent body contouring procedures. Little is known, however, about body image changes and associated features from pre-to post-bariatric surgery and subsequent body contouring. The objective of the present study was to conduct a comprehensive literature review of body image following bariatric surgery to help inform future clinical research and care. The articles for the current review were identified by searching PubMed and SCOPUS and references from relevant articles. A total of 60 articles examining body image post-bariatric surgery were identified, and 45 did not include body contouring surgery. Overall, there was great variation in standards of reporting sample characteristics and body image terms. When examining broad levels of body image dissatisfaction, the literature suggests general improvements in certain aspects of body image following bariatric surgery; however, few studies have systematically examined various body image domains from pre-to post-bariatric surgery and subsequent body contouring surgery. In conclusion, there is a paucity of research that examines the multidimensional elements of body image following bariatric surgery. © 2018 World Obesity Federation.
In vivo near-IR imaging of approximal dental decay at 1,310 nm.
Staninec, Michal; Lee, Chulsung; Darling, Cynthia L; Fried, Daniel
2010-04-01
The high transparency of dental enamel in the near-IR (NIR) light at 1,310-nm can be exploited for imaging dental caries without the use of ionizing radiation (X-rays). We present the results of the first in vivo imaging study in which NIR images were acquired of approximal contact surfaces. NIR imaging hand-pieces were developed and attached to a compact InGaAs focal plane array and subsequently used to acquire in vivo NIR images of 33 caries lesions on 18 test subjects. The carious lesions were discernible on bitewing radiographs, but were not visible upon clinical examination. NIR images were acquired in vivo from three directions and the majority of lesions examined were too small to require restoration, based on accepted bitewing radiograph criteria. All but one of the 33 lesions examined were successfully imaged from at least one direction. This first in vivo study of imaging at the 1,310-nm wavelength region shows that NIR imaging has great potential as a screening tool for the detection of approximal lesions without the use of ionizing radiation. (c) 2010 Wiley-Liss, Inc.
ERIC Educational Resources Information Center
Daniels, Elizabeth A.
2009-01-01
In contrast to the large body of research examining the negative effects of idealized media images on girls' and women's body image, little research has investigated whether media images can positively impact body concept among females. Using a between-participants experimental design, this study examined how images of performance athletes,…
Mirham, Lorna; Naugler, Christopher; Hayes, Malcolm; Ismiil, Nadia; Belisle, Annie; Sade, Shachar; Streutker, Catherine; MacMillan, Christina; Rasty, Golnar; Popovic, Snezana; Joseph, Mariamma; Gabril, Manal; Barnes, Penny; Hegele, Richard G.; Carter, Beverley; Yousef, George M.
2016-01-01
Background: It is anticipated that many licensing examination centres for pathology will begin fully digitizing the certification examinations. The objective of our study was to test the feasibility of a fully digital examination and to assess the needs, concerns and expectations of pathology residents in moving from a glass slide-based examination to a fully digital examination. Methods: We conducted a mixed methods study that compared, after randomization, the performance of senior residents (postgraduate years 4 and 5) in 7 accredited anatomical pathology training programs across Canada on a pathology examination using either glass slides or digital whole-slide scanned images of the slides. The pilot examination was followed by a post-test survey. In addition, pathology residents from all levels of training were invited to participate in an online survey. Results: A total of 100 residents participated in the pilot examination; 49 were given glass slides instead of digital images. We found no significant difference in examination results between the 2 groups of residents (estimated marginal mean 8.23/12, 95% confidence interval [CI] 7.72-8.87, for glass slides; 7.84/12, 95% CI 7.28-8.41, for digital slides). In the post-test survey, most of the respondents expressed concerns with the digital examination, including slowly functioning software, blurring and poor detail of images, particularly nuclear features. All of the respondents of the general survey (n = 179) agreed that additional training was required if the examination were to become fully digital. Interpretation: Although the performance of residents completing pathology examinations with glass slides was comparable to that of residents using digital images, our study showed that residents were not comfortable with the digital technology, especially given their current level of exposure to it. Additional training may be needed before implementing a fully digital examination, with consideration for a gradual transition. PMID:27280119
Ohno, Yasuharu; Fujimoto, Tamotsu; Shibata, Yukari
2017-02-01
Introduction Superb microvascular imaging is a new ultrasound image processing technique that uses advanced clutter suppression to extract flow signals from vessels and which helps us visualize very small vascular structures that were not previously visible without the use of a contrast agent. We herein analyzed the usefulness of superb microvascular imaging in the diagnosis of hepato-gastrointestinal disorders in pediatric patients. Materials and Methods Fifty-six pediatric patients who underwent a total of 81 superb microvascular imaging examinations with an Aplio 300 ultrasound system (Toshiba Medical Systems, Tokyo, Japan) were enrolled in this study. The subjects underwent conventional ultrasound examinations, including Doppler imaging followed by superb microvascular imaging. The superb microvascular imaging findings and standard imaging were compared. All of the examinations were performed without sedation. Results The average age of the patients (male, n = 38; female, n = 18) was 4 years. The clinical diagnoses included hepatobiliary disorders ( n = 29), acute appendicitis ( n = 10), and other intestinal disorders ( n = 17). The target organs for superb microvascular imaging were the liver, appendix, rectum, intestine, gallbladder, and lymph node. In most of the patients, superb microvascular imaging achieved the excellent visualization of microvascular structures, revealing abnormal vasculature in 21 out of 46 (45.7%) examinations of the liver, 9/9 (100%) examinations of the appendix, 0/11 (0%) examinations of the rectum, 9/11 (81.8%) examinations of the intestine, 0/1 (0%) examinations of the gallbladder, and 3/3 (100%) examinations of the lymph nodes. Superb microvascular imaging was superior to Doppler imaging for depicting the microvascular structures. Conclusions Superb microvascular imaging is especially useful for depicting the microvascular flow and can aid in the diagnosis and treatment planning for pediatric patients with hepato-gastrointestinal disorders. Georg Thieme Verlag KG Stuttgart · New York.
Beauty and Body Image Concerns Among African American College Women
Awad, Germine H.; Norwood, Carolette; Taylor, Desire S.; Martinez, Mercedes; McClain, Shannon; Jones, Bianca; Holman, Andrea; Chapman-Hilliard, Collette
2014-01-01
The current study examined body image concerns among African American women. In recent years, there has been an attempt to include ethnic minority samples in body image studies (e.g., Grabe & Hyde, 2006; Hrabosky & Grilo, 2007; Lovejoy, 2001) but few specifically examine unique issues pertaining to beauty and body image for African American college age women. A total of 31 African American women participated in one of five focus groups on the campus of a large Southwestern University to examine beauty and body image. Data were analyzed using a thematic approach and several themes were identified. The majority of themes pertained to issues related to hair, skin tone, body type, and message sources. Themes included: sacrifice, ignorance/racial microaggressions, and validation and invalidation by others, thick/toned/curvy as optimal, hypersexualization, and being thin is for White women. Findings of the current study suggest a reconceptualization of body image for African American women where relevant characteristics such as hair and skin tone are given more priority over traditional body image concerns often associated with European American women. PMID:26778866
Palermo, Fernanda Gasparin; Albuquerque, Débora de Paula Soares de Medeiros; Martins, Wellington P; Araujo Júnior, Edward; Bruns, Rafael Frederico
2016-09-01
To establish a structured review process to facilitate the identification of the fetal nasal bone (NB) in the first trimester ultrasound scan to improve the quality images. We conducted a retrospective observational study in fetal NB images obtained during ultrasound exams of singleton pregnancies that underwent first trimester screening (crown-rump length 45-84 mm). When the images were obtained the examiner was not aware of the study. Audit was conducted by an examiner according criteria established by the Fetal Medicine Foundation. Fetal NB images were assessed regarding adequate magnification, mid-sagittal view and transducer held parallel to the direction of the nose. The transvaginal and transabdominal as well as anterior and posterior fetal back groups were compared using χ(2) test. We considered 874 fetal NB images for auditing. Fetal NB was considered present in 865 images (99%). During the audit process, we identified 72 (8.2%) cases of disagreement between examiner and auditor assessments. Disagreement was higher when image quality was poor (62 cases = 7%). Transvaginal approach performed better in the following criteria: adequate magnification (p < 0.001), midline (p < 0.001) and completely adequate (p < 0.001). A peer reviewed audit program for fetal NB is feasible in a clinical scenario. Image quality appears to play an important role in compliance to image standards audited and in agreement between examiner and auditor.
Effect of image resolution manipulation in rearfoot angle measurements obtained with photogrammetry
Sacco, I.C.N.; Picon, A.P.; Ribeiro, A.P.; Sartor, C.D.; Camargo-Junior, F.; Macedo, D.O.; Mori, E.T.T.; Monte, F.; Yamate, G.Y.; Neves, J.G.; Kondo, V.E.; Aliberti, S.
2012-01-01
The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol. PMID:22911379
Effect of image resolution manipulation in rearfoot angle measurements obtained with photogrammetry.
Sacco, I C N; Picon, A P; Ribeiro, A P; Sartor, C D; Camargo-Junior, F; Macedo, D O; Mori, E T T; Monte, F; Yamate, G Y; Neves, J G; Kondo, V E; Aliberti, S
2012-09-01
The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol.
Endemic Images and the Desensitization Process.
ERIC Educational Resources Information Center
Saigh, Philip A.; Antoun, Fouad T.
1984-01-01
Examined the effects of endemic images on levels of anxiety and achievement of 48 high school students. Results suggested that a combination of endemic images and study skills training was as effective as desensitization plus study skills training. Includes the endemic image questionnaire. (JAC)
Rosenkrantz, Andrew B; Jacobs, Jill E; Jain, Nidhi; Brusca-Augello, Geraldine; Mechlin, Michael; Parente, Marc; Recht, Michael P
2017-12-01
Radiologic technologists may repeat images within a radiographic examination because of perceived suboptimal image quality, excluding these original images from submission to a PACS. This study assesses the appropriateness of technologists' decisions to repeat musculoskeletal and chest radiographs as well as the utility of repeat radiographs in addressing examinations' clinical indication. We included 95 musculoskeletal and 87 chest radiographic examinations in which the technologist repeated one or more images because of perceived image quality issues, rejecting original images from PACS submission. Rejected images were retrieved from the radiograph unit and uploaded for viewing on a dedicated server. Musculoskeletal and chest radiologists reviewed rejected and repeat images in their timed sequence, in addition to the studies' remaining images. Radiologists answered questions regarding the added value of repeat images. The reviewing radiologist agreed with the reason for rejection for 64.2% of musculoskeletal and 60.9% of chest radiographs. For 77.9% and 93.1% of rejected radiographs, the clinical inquiry could have been satisfied without repeating the image. For 75.8% and 64.4%, the repeated images showed improved image quality. Only 28.4% and 3.4% of repeated images were considered to provide additional information that was helpful in addressing the clinical question. Most repeated radiographs (chest more so than musculoskeletal radiographs) did not add significant clinical information or alter diagnosis, although they did increase radiation exposure. The decision to repeat images should be made after viewing the questionable image in context with all images in a study and might best be made by a radiologist rather than the performing technologist.
Hahn, D; Beer, M; Sandstede, J
2000-10-01
The introduction of magnetic resonance (MR) tomography has fundamentally changed radiological diagnosis for many diseases. Invasive digital subtraction angiography has already been widely replaced by noninvasive MR angiography for most of the vascular diseases. The rapid technical development of MR imaging in recent years has opened new functional imaging techniques. MR imaging of the heart allows simultaneous measurement of morphological and functional parameters in a single noninvasive examination without any radiation exposure. Because of the high spatial resolution and the reproducibility cine MR imaging is now the gold standard for functional analysis. With the improvement of myocardial perfusion and viability studies many diseases of the heart can be diagnosed in a single examination. MR spectroscopy is the only method which allows a view of the metabolism of the heart. New examinations for vascular imaging and flow quantification complete the goal of "one-stop-shop" imaging of the heart. MR imaging is the only diagnostic modality which allows a complete evaluation of many diseases of the heart with one technique, basic examination as well as follow-up studies. The very rapid improvement in MRI will overcome most of the limitations in the near future, especially concerning MR coronary angiography.
Haldane, Chloe E; Ekhtiari, Seper; de Sa, Darren; Simunovic, Nicole; Ayeni, Olufemi R
2017-08-01
The purpose of this systematic review is to report current preoperative assessment for femoroacetabular impingement (FAI) including physical examination and imaging modalities prior to hip arthroscopy, and report current imaging measures used in the diagnosis of FAI. The electronic databases MEDLINE, EMBASE and PubMed were searched and screened in duplicate for relevant studies. Data regarding patient demographics, non-operative treatment, preoperative assessment including physical examination and imaging prior to hip arthroscopy were abstracted. Study quality was assessed in duplicate using the Methodological Index for Non-Randomized Studies criteria. Sixty-eight studies of fair quality evidence that involved a total of 5125 patients (5400 hips) were included. In total, 56% of all patients were male and mean age was 36 years (SD ± 10.0). Within physical examination, FADIR impingement testing was reported in 57% of patients. All included studies reported plain radiographic imaging as a component of preoperative assessment with anterior-posterior pelvis view being the most commonly reported view, followed by the cross-table lateral and Dunn views. Magnetic resonance imaging was obtained for 52% of included patients and computed tomography for 26% of patients. The most commonly reported measure within imaging for the diagnosis of cam type impingement was alpha angle (66%), whereas for pincer type impingement, the cross-over sign (48%) was most reported. Preoperative assessment is underreported in the FAI literature. Improved reporting is warranted to develop a more consistent and validated diagnostic algorithm for FAI to enhance patient selection. Level of evidence : Level IV, Systematic Review of Level I-IV Studies.
Haldane, Chloe E.; Ekhtiari, Seper; de SA, Darren; Simunovic, Nicole
2017-01-01
Abstract The purpose of this systematic review is to report current preoperative assessment for femoroacetabular impingement (FAI) including physical examination and imaging modalities prior to hip arthroscopy, and report current imaging measures used in the diagnosis of FAI. The electronic databases MEDLINE, EMBASE and PubMed were searched and screened in duplicate for relevant studies. Data regarding patient demographics, non-operative treatment, preoperative assessment including physical examination and imaging prior to hip arthroscopy were abstracted. Study quality was assessed in duplicate using the Methodological Index for Non-Randomized Studies criteria. Sixty-eight studies of fair quality evidence that involved a total of 5125 patients (5400 hips) were included. In total, 56% of all patients were male and mean age was 36 years (SD ± 10.0). Within physical examination, FADIR impingement testing was reported in 57% of patients. All included studies reported plain radiographic imaging as a component of preoperative assessment with anterior–posterior pelvis view being the most commonly reported view, followed by the cross-table lateral and Dunn views. Magnetic resonance imaging was obtained for 52% of included patients and computed tomography for 26% of patients. The most commonly reported measure within imaging for the diagnosis of cam type impingement was alpha angle (66%), whereas for pincer type impingement, the cross-over sign (48%) was most reported. Preoperative assessment is underreported in the FAI literature. Improved reporting is warranted to develop a more consistent and validated diagnostic algorithm for FAI to enhance patient selection. Level of evidence: Level IV, Systematic Review of Level I–IV Studies. PMID:28948032
Morgan, Matthew B; Young, Elizabeth; Harada, Scott; Winkler, Nicole; Riegert, Joanna; Jones, Tony; Hu, Nan; Stein, Matthew
2017-12-01
In screening mammography, accessing prior examination images is crucial for accurate diagnosis and avoiding false-positives. When women visit multiple institutions for their screens, these "outside" examinations must be retrieved for comparison. Traditionally, prior images are obtained by faxing requests to other institutions and waiting for standard mail (film or CD-ROM), which can greatly delay report turnaround times. Recently, advancements in cloud-based image transfer technology have opened up more efficient options for examination transfer between institutions. The objective of this study was to evaluate the effect of cloud-based image transfer on mammography department workflow, time required to obtain prior images, and report turnaround times. Sixty screening examinations requiring prior images were placed into two groups (30 each). The control group used the standard institutional protocol for requesting prior images: faxing requests and waiting for mailed examinations. The experimental group used a cloud-based transfer for both requesting and receiving examinations. The mean number of days between examination request and examination receipt was measured for both groups and compared. The mean number of days from examination request to receipt was 6.08 days (SD 3.50) in the control group compared with 3.16 days (SD 3.95) in the experimental group. Using a cloud-based image transfer to obtain prior mammograms resulted in an average reduction of 2.92 days (P = .0361; 95% confidence interval 0.20-5.65) between examination request and receipt. This improvement in system efficiency is relevant for interpreting radiologists working to improve reporting times and for patients anxious to receive their mammography results. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Yoda, Kazushige; Umeda, Tokuo; Hasegawa, Tomoyuki
2003-11-01
Organ movements that occur naturally as a result of vital functions such as respiration and heartbeat cause deterioration of image quality in nuclear medicine imaging. Among these movements, respiration has a large effect, but there has been no practical method of correcting for this. In the present study, we examined a method of correction that uses ultrasound images to correct baseline shifts caused by respiration in cardiac nuclear medicine examinations. To evaluate the validity of this method, simulation studies were conducted with an X-ray TV machine instead of a nuclear medicine scanner. The X-ray TV images and ultrasound images were recorded as digital movies and processed with public domain software (Scion Image). Organ movements were detected in the ultrasound images of the subcostal four-chamber view mode using slit regions of interest and were measured on a two-dimensional image coordinate. Then translational shifts were applied to the X-ray TV images to correct these movements by using macro-functions of the software. As a result, respiratory movements of about 20.1 mm were successfully reduced to less than 2.6 mm. We conclude that this correction technique is potentially useful in nuclear medicine cardiology.
International students' image of rural Pennsylvania as a travel destination
Po-Ju Chen; Deborah L. Kerstetter
1998-01-01
The purpose of this study was to examine the image international students at Penn State have of rural travel destinations in the state of Pennsylvania. In addition, this study investigated whether destination image differed depending upon travel behavior and socio-demographic variables. Four distinct image dimensions, "tourism infrastructure," "...
ERIC Educational Resources Information Center
Lane, Ciara; Stynes, Martin; O'Donoghue, John
2016-01-01
A questionnaire survey was carried out as part of a PhD research study to investigate the image of mathematics held by post-primary students in Ireland. The study focused on students in fifth year of post-primary education studying ordinary level mathematics for the Irish Leaving Certificate examination--the final examination for students in…
Methods to prefetch comparison images in image management and communication system
NASA Astrophysics Data System (ADS)
Levin, Kenneth; Fielding, Robert
1990-08-01
A high-level description of a system to pre-fetch comparison radiographs in an Image Management and Communication System (IMAC) is presented. This rule based system estimates the relevance of previous examinations for comparison to the current examination arid uses this determination to pre-fetch comparison studies. A machine learning module should allow the system to improve its skill in pre-fetching examinations for each individual radiologist. This system could be tailored to fit the desires of individual radiologists.
[Application of computed tomography (CT) examination for forensic medicine].
Urbanik, Andrzej; Chrzan, Robert
2013-01-01
The aim of the study is to present a own experiences in usage of post mortem CT examination for forensic medicine. With the help of 16-slice CT scanner 181 corpses were examined. Obtained during acquisition imaging data are later developed with dedicated programmes. Analyzed images were extracted from axial sections, multiplanar reconstructions as well as 3D reconstructions. Gained information helped greatly when classical autopsy was performed by making it more accurate. A CT scan images recorded digitally enable to evaluate corpses at any time, despite processes of putrefaction or cremation. If possible CT examination should precede classical autopsy.
Wagner, Mathilde; Maggiori, Léon; Ronot, Maxime; Paradis, Valérie; Vilgrain, Valérie; Panis, Yves; Van Beers, Bernard E
2013-08-01
To compare diffusion-weighted (DW) and T2-weighted MR imaging in detecting colorectal liver metastases in a rat model, using histological examination as a reference method. Eighteen rats had four liver injections of colon cancer cells. MR examinations at 7 T included FSE-T2-weighted imaging and SE-DW MR imaging (b = 0, 20 and 150 s/mm(2)) and were analysed by two independent readers. Histological examination was performed on 0.4-mm slices. McNemar's test was used to compare the sensitivities and the Wilcoxon matched pairs test to compare the average number of false-positives per rat. One hundred and sixty-six liver metastases were identified on histological examination. The sensitivity in detecting liver metastases was significantly higher on DW MR than on T2-weighted images (99/166 (60 %) (reader 1) and 92/166 (55 %) (reader 2) versus 77/166 (46 %), P ≤ 0.001), without an increase in false-positives per rat (P = 0.773/P = 0.850). After stratification according to metastasis diameter, DW MR imaging had a significantly higher sensitivity than T2-weighted imaging only for metastases with a diameter (0.6-1.2 mm) similar to that of the spatial resolution of MR imaging in the current study. This MR study with histological correlations shows the higher sensitivity of DW relative to T2-weighted imaging at 7 T for detecting liver metastases, especially small ones. • Diffusion weighted (DW) sequences are increasingly used in magnetic resonance imaging (MRI). • DW has higher sensitivity for liver metastases than T2-weighted imaging at 7 T. • This increase in sensitivity is especially marked for small liver metastasis detection. • This higher sensitivity is confirmed in an animal model with histological correlation. • DW imaging has the potential for earlier diagnosis of small liver metastases.
Ahlander, Britt-Marie; Årestedt, Kristofer; Engvall, Jan; Maret, Eva; Ericsson, Elisabeth
2016-06-01
To develop and validate a new instrument measuring patient anxiety during Magnetic Resonance Imaging examinations, Magnetic Resonance Imaging- Anxiety Questionnaire. Questionnaires measuring patients' anxiety during Magnetic Resonance Imaging examinations have been the same as used in a wide range of conditions. To learn about patients' experience during examination and to evaluate interventions, a specific questionnaire measuring patient anxiety during Magnetic Resonance Imaging is needed. Psychometric cross-sectional study with test-retest design. A new questionnaire, Magnetic Resonance Imaging-Anxiety Questionnaire, was designed from patient expressions of anxiety in Magnetic Resonance Imaging-scanners. The sample was recruited between October 2012-October 2014. Factor structure was evaluated with exploratory factor analysis and internal consistency with Cronbach's alpha. Criterion-related validity, known-group validity and test-retest was calculated. Patients referred for Magnetic Resonance Imaging of either the spine or the heart, were invited to participate. The development and validation of Magnetic Resonance Imaging-Anxiety Questionnaire resulted in 15 items consisting of two factors. Cronbach's alpha was found to be high. Magnetic Resonance Imaging-Anxiety Questionnaire correlated higher with instruments measuring anxiety than with depression scales. Known-group validity demonstrated a higher level of anxiety for patients undergoing Magnetic Resonance Imaging scan of the heart than for those examining the spine. Test-retest reliability demonstrated acceptable level for the scale. Magnetic Resonance Imaging-Anxiety Questionnaire bridges a gap among existing questionnaires, making it a simple and useful tool for measuring patient anxiety during Magnetic Resonance Imaging examinations. © 2016 The Authors. Journal of Advanced Nursing Published by John Wiley & Sons Ltd.
Rigsby, Cynthia K; McKenney, Sarah E; Hill, Kevin D; Chelliah, Anjali; Einstein, Andrew J; Han, B Kelly; Robinson, Joshua D; Sammet, Christina L; Slesnick, Timothy C; Frush, Donald P
2018-01-01
Children with congenital or acquired heart disease can be exposed to relatively high lifetime cumulative doses of ionizing radiation from necessary medical imaging procedures including radiography, fluoroscopic procedures including diagnostic and interventional cardiac catheterizations, electrophysiology examinations, cardiac computed tomography (CT) studies, and nuclear cardiology examinations. Despite the clinical necessity of these imaging studies, the related ionizing radiation exposure could pose an increased lifetime attributable cancer risk. The Image Gently "Have-A-Heart" campaign is promoting the appropriate use of medical imaging studies in children with congenital or acquired heart disease while minimizing radiation exposure. The focus of this manuscript is to provide a comprehensive review of radiation dose management and CT performance in children with congenital or acquired heart disease.
Patel, Kunal S; Yao, Yong; Wang, Renzhi; Carter, Bob S; Chen, Clark C
2016-04-01
To review the utility of intraoperative imaging in facilitating maximal resection of non-functioning pituitary adenomas (NFAs). We performed an exhaustive MEDLINE search, which yielded 5598 articles. Upon careful review of these studies, 31 were pertinent to the issue of interest. Nine studies examined whether intraoperative MRI (iMRI) findings correlated with the presence of residual tumor on MRI taken 3 months after surgical resection. All studies using iMRI of >0.15T showed a ≥90% concordance between iMRI and 3-month post-operative MRI findings. 24 studies (22 iMRI and 2 intraoperative CT) examined whether intraoperative imaging improved the surgeon's ability to achieve a more complete resection. The resections were carried out under microscopic magnification in 17 studies and under endoscopic visualization in 7 studies. All studies support the value of intraoperative imaging in this regard, with improved resection in 15-83% of patients. Two studies examined whether iMRI (≥0.3T) improved visualization of residual NFA when compared to endoscopic visualization. Both studies demonstrated the value of iMRI in this regard, particularly when the tumor is located lateral of the sella, in the cavernous sinus, and in the suprasellar space. The currently available literature supports the utility of intraoperative imaging in facilitating increased NFA resection, without compromising safety.
[Development of a digital chest phantom for studies on energy subtraction techniques].
Hayashi, Norio; Taniguchi, Anna; Noto, Kimiya; Shimosegawa, Masayuki; Ogura, Toshihiro; Doi, Kunio
2014-03-01
Digital chest phantoms continue to play a significant role in optimizing imaging parameters for chest X-ray examinations. The purpose of this study was to develop a digital chest phantom for studies on energy subtraction techniques under ideal conditions without image noise. Computed tomography (CT) images from the LIDC (Lung Image Database Consortium) were employed to develop a digital chest phantom. The method consisted of the following four steps: 1) segmentation of the lung and bone regions on CT images; 2) creation of simulated nodules; 3) transformation to attenuation coefficient maps from the segmented images; and 4) projection from attenuation coefficient maps. To evaluate the usefulness of digital chest phantoms, we determined the contrast of the simulated nodules in projection images of the digital chest phantom using high and low X-ray energies, soft tissue images obtained by energy subtraction, and "gold standard" images of the soft tissues. Using our method, the lung and bone regions were segmented on the original CT images. The contrast of simulated nodules in soft tissue images obtained by energy subtraction closely matched that obtained using the gold standard images. We thus conclude that it is possible to carry out simulation studies based on energy subtraction techniques using the created digital chest phantoms. Our method is potentially useful for performing simulation studies for optimizing the imaging parameters in chest X-ray examinations.
The purpose of this study is to examine the feasibility of collecting, transmitting,
and analyzing 3-D ultrasound data in the context of a multi-center study of pregnant
women. The study will also examine the reliability of measurements obtained from 3-D
imag...
Rodgers, Rachel F; Lowy, Alice S; Halperin, Daniella M; Franko, Debra L
2016-01-01
Previous research has indicated that exposure to pro-eating disorder websites might increase eating pathology; however, the magnitude of this effect is unknown. This study aimed to conduct a systematic review and meta-analysis to examine the effect of exposure to pro-eating disorder websites on body image and eating pathology. Studies examining the relationship between exposure to pro-eating disorder websites and eating pathology-related outcomes were included. The systematic review identified nine studies. Findings revealed significant effect sizes of exposure to pro-eating disorder websites on body image dissatisfaction (five studies), d = .41, p = .003; dieting (six studies), d = .68, p < .001, and negative affect (three studies), d = 1.00, p < .001. No effect emerged for bulimic symptoms (four studies), d = .22, p = .73. Findings confirmed the effect of pro-eating disorder websites on body image and eating pathology, highlighting the need for enforceable regulation of these websites. Copyright © 2015 John Wiley & Sons, Ltd and Eating Disorders Association.
NASA Astrophysics Data System (ADS)
Nagai, Yuichi; Kitagawa, Mayumi; Torii, Jun; Iwase, Takumi; Aso, Tomohiko; Ihara, Kanyu; Fujikawa, Mari; Takeuchi, Yumiko; Suzuki, Katsumi; Ishiguro, Takashi; Hara, Akio
2014-03-01
Recently, the double contrast technique in a gastrointestinal examination and the transbronchial lung biopsy in an examination for the respiratory system [1-3] have made a remarkable progress. Especially in the transbronchial lung biopsy, better quality of x-ray fluoroscopic images is requested because this examination is performed under a guidance of x-ray fluoroscopic images. On the other hand, various image processing methods [4] for x-ray fluoroscopic images have been developed as an x-ray system with a flat panel detector [5-7] is widely used. A recursive filtering is an effective method to reduce a random noise in x-ray fluoroscopic images. However it has a limitation for its effectiveness of a noise reduction in case of a moving object exists in x-ray fluoroscopic images because the recursive filtering is a noise reduction method by adding last few images. After recursive filtering a residual signal was produced if a moving object existed in x-ray images, and this residual signal disturbed a smooth procedure of the examinations. To improve this situation, new noise reduction method has been developed. The Adaptive Noise Reduction [ANR] is the brand-new noise reduction technique which can be reduced only a noise regardless of the moving object in x-ray fluoroscopic images. Therefore the ANR is a very suitable noise reduction method for the transbronchial lung biopsy under a guidance of x-ray fluoroscopic images because the residual signal caused of the moving object in x-ray fluoroscopic images is never produced after the ANR. In this paper, we will explain an advantage of the ANR by comparing of a performance between the ANR images and the conventional recursive filtering images.
Dual-modal photoacoustic and ultrasound imaging of dental implants
NASA Astrophysics Data System (ADS)
Lee, Donghyun; Park, Sungjo; Kim, Chulhong
2018-02-01
Dental implants are common method to replace decayed or broken tooth. As the implant treatment procedures varies according to the patients' jawbone, bone ridge, and sinus structure, appropriate examinations are necessary for successful treatment. Currently, radiographic examinations including periapical radiology, panoramic X-ray, and computed tomography are commonly used for diagnosing and monitoring. However, these radiographic examinations have limitations in that patients and operators are exposed to radioactivity and multiple examinations are performed during the treatment. In this study, we demonstrated photoacoustic (PA) and ultrasound (US) combined imaging of dental implant that can lower the total amount of absorbed radiation dose in dental implant treatment. An acoustic resolution PA macroscopy and a clinical PA/US system was used for dental implant imaging. The acquired dual modal PA/US imaging results support that the proposed photoacoustic imaging strategy can reduce the radiation dose rate during dental implant treatment.
Image dependency in the recognition of newly learnt faces.
Longmore, Christopher A; Santos, Isabel M; Silva, Carlos F; Hall, Abi; Faloyin, Dipo; Little, Emily
2017-05-01
Research investigating the effect of lighting and viewpoint changes on unfamiliar and newly learnt faces has revealed that such recognition is highly image dependent and that changes in either of these leads to poor recognition accuracy. Three experiments are reported to extend these findings by examining the effect of apparent age on the recognition of newly learnt faces. Experiment 1 investigated the ability to generalize to novel ages of a face after learning a single image. It was found that recognition was best for the learnt image with performance falling the greater the dissimilarity between the study and test images. Experiments 2 and 3 examined whether learning two images aids subsequent recognition of a novel image. The results indicated that interpolation between two studied images (Experiment 2) provided some additional benefit over learning a single view, but that this did not extend to extrapolation (Experiment 3). The results from all studies suggest that recognition was driven primarily by pictorial codes and that the recognition of faces learnt from a limited number of sources operates on stored images of faces as opposed to more abstract, structural, representations.
NASA Astrophysics Data System (ADS)
Svalkvist, Angelica; Hansson, Jonny; Bâth, Magnus
2014-03-01
Three-dimensional (3D) imaging with interventional fluoroscopy systems is today a common examination. The examination includes acquisition of two-dimensional projection images, used to reconstruct section images of the patient. The aim of the present study was to investigate the difference in resulting effective dose obtained using different levels of complexity in calculations of effective doses from these examinations. In the study the Siemens Artis Zeego interventional fluoroscopy system (Siemens Medical Solutions, Erlangen, Germany) was used. Images of anthropomorphic chest and pelvis phantoms were acquired. The exposure values obtained were used to calculate the resulting effective doses from the examinations, using the computer software PCXMC (STUK, Helsinki, Finland). The dose calculations were performed using three different methods: 1. using individual exposure values for each projection image, 2. using the mean tube voltage and the total DAP value, evenly distributed over the projection images, and 3. using the mean kV and the total DAP value, evenly distributed over smaller selection of projection images. The results revealed that the difference in resulting effective dose between the first two methods was smaller than 5%. When only a selection of projection images were used in the dose calculations the difference increased to over 10%. Given the uncertainties associated with the effective dose concept, the results indicate that dose calculations based on average exposure values distributed over a smaller selection of projection angles can provide reasonably accurate estimations of the radiation doses from 3D imaging using interventional fluoroscopy systems.
Application of dermoscopy image analysis technique in diagnosing urethral condylomata acuminata.
Zhang, Yunjie; Jiang, Shuang; Lin, Hui; Guo, Xiaojuan; Zou, Xianbiao
2018-01-01
In this study, cases with suspected urethral condylomata acuminata were examined by dermoscopy, in order to explore an effective method for clinical. To study the application of dermoscopy image analysis technique in clinical diagnosis of urethral condylomata acuminata. A total of 220 suspected urethral condylomata acuminata were clinically diagnosed first with the naked eyes, and then by using dermoscopy image analysis technique. Afterwards, a comparative analysis was made for the two diagnostic methods. Among the 220 suspected urethral condylomata acuminata, there was a higher positive rate by dermoscopy examination than visual observation. Dermoscopy examination technique is still restricted by its inapplicability in deep urethral orifice and skin wrinkles, and concordance between different clinicians may also vary. Dermoscopy image analysis technique features a high sensitivity, quick and accurate diagnosis and is non-invasive, and we recommend its use.
Perceptual expertise in forensic facial image comparison
White, David; Phillips, P. Jonathon; Hahn, Carina A.; Hill, Matthew; O'Toole, Alice J.
2015-01-01
Forensic facial identification examiners are required to match the identity of faces in images that vary substantially, owing to changes in viewing conditions and in a person's appearance. These identifications affect the course and outcome of criminal investigations and convictions. Despite calls for research on sources of human error in forensic examination, existing scientific knowledge of face matching accuracy is based, almost exclusively, on people without formal training. Here, we administered three challenging face matching tests to a group of forensic examiners with many years' experience of comparing face images for law enforcement and government agencies. Examiners outperformed untrained participants and computer algorithms, thereby providing the first evidence that these examiners are experts at this task. Notably, computationally fusing responses of multiple experts produced near-perfect performance. Results also revealed qualitative differences between expert and non-expert performance. First, examiners' superiority was greatest at longer exposure durations, suggestive of more entailed comparison in forensic examiners. Second, experts were less impaired by image inversion than non-expert students, contrasting with face memory studies that show larger face inversion effects in high performers. We conclude that expertise in matching identity across unfamiliar face images is supported by processes that differ qualitatively from those supporting memory for individual faces. PMID:26336174
ERIC Educational Resources Information Center
Lincoln, Yvonna S.
This descriptive study examines how the proliferation of electronic hook-ups to remote locations, to databases, and particularly to electronic mail (e-mail), is changing the work, communication patterns and self-image of higher education faculty. In particular the study examined whether technological acquisition had an impact on professors'…
A Cognitive Semiotic Study of Students' Reading a Textless Image versus a Verbal Image
ERIC Educational Resources Information Center
Ali, Roaa Hasan; Aslaadi, Shatha
2016-01-01
This study explores fourth year college students' content retrieval from reading textless versus verbal images. Furthermore, it examines the extent to which the respondents comprehend and understand them. The procedures include selecting an image from the internet, designing a written test with its rubrics and exposing it to jury members to…
Cordon, Ingrid M; Melinder, Annika M D; Goodman, Gail S; Edelstein, Robin S
2013-02-01
Two studies were conducted to examine theoretical questions about children's and adults' memory for emotional visual stimuli. In Study 1, 7- to 9-year-olds and adults (N=172) participated in the initial creation of the Developmental Affective Photo System (DAPS). Ratings of emotional valence, arousal, and complexity were obtained. In Study 2, DAPS pictures were presented to 20 8- to 12-year-olds and 30 adults, followed by a recognition memory test. Children and adults recognized aversive images better than neutral images. Moreover, children and adults recognized high and moderate arousal images more accurately than low arousal images. Adults' memory for neutral images exceeded that of children, but there were no developmental differences in memory for aversive pictures. Theoretical and methodological implications are discussed. Copyright © 2012 Elsevier Inc. All rights reserved.
Liu, Zan; Qian, Junchao; Liu, Binmei; Wang, Qi; Ni, Xiaoyu; Dong, Yaling; Zhong, Kai; Wu, Yuejin
2014-01-01
Although paramagnetic contrast agents have a wide range of applications in medical studies involving magnetic resonance imaging (MRI), these agents are seldom used to enhance MRI images of plant root systems. To extend the application of MRI contrast agents to plant research and to develop related techniques to study root systems, we examined the applicability of the MRI contrast agent Gd-DTPA to the imaging of rice roots. Specifically, we examined the biological effects of various concentrations of Gd-DTPA on rice growth and MRI images. Analysis of electrical conductivity and plant height demonstrated that 5 mmol Gd-DTPA had little impact on rice in the short-term. The results of signal intensity and spin-lattice relaxation time (T1) analysis suggested that 5 mmol Gd-DTPA was the appropriate concentration for enhancing MRI signals. In addition, examination of the long-term effects of Gd-DTPA on plant height showed that levels of this compound up to 5 mmol had little impact on rice growth and (to some extent) increased the biomass of rice.
A pilot study examining correlates of body image among women living with SCI.
Bassett, R L; Martin Ginis, K A; Buchholz, A C
2009-06-01
Cross-sectional pilot study. To explore correlates of body image among women with spinal cord injury (SCI), within the framework of Cash's cognitive behavioral model of body image. Hamilton, Ontario, Canada. Women with SCI (N=11, 64% with tetraplegia) reported their functional and appearance body image (Adult Body Satisfaction Questionnaire). A 3-day recall of leisure time physical activity (LTPA), three measures of body composition (that is, weight, waist circumference, body fat) and several demographic variables were assessed as potential correlates. Appearance satisfaction was negatively correlated with all three measures of body composition and positively correlated with years postinjury. Functional satisfaction was positively correlated with years postinjury, and negatively correlated with various LTPA variables. Functional and appearance body image may improve with time following SCI. Body composition may impact satisfaction with physical appearance for some women. The negative relationship between LTPA and functional satisfaction merits further examination, as functional dissatisfaction may motivate individuals to engage in certain types and intensities of LTPA. Correlates of body image differ between appearance and functional satisfaction. Future research should examine appearance and functional satisfaction separately among women with SCI.
Country Image and the Study Abroad Destination Choice of Students from Mainland China
ERIC Educational Resources Information Center
Ghazarian, Peter G.
2016-01-01
In this study, the author focuses on the issue of country image in destination choice. To examine the relationship between these two variables, the study tests whether mainland Chinese who favor a destination as their ideal first choice for study abroad have a significantly more positive view of that destination's country image than their…
Bellaïche, L; Laredo, J D; Lioté, F; Koeger, A C; Hamze, B; Ziza, J M; Pertuiset, E; Bardin, T; Tubiana, J M
1997-11-01
A prospective multicenter study. To evaluate the use of magnetic resonance imaging, in the differentiation between monoclonal gammopathies of unknown significance and multiple myeloma. Although multiple myeloma has been studied extensively with magnetic resonance imaging, to the authors' knowledge, no study has evaluated the clinical interest of magnetic resonance imaging in the differentiation between monoclonal gammopathies of unknown significance and multiple myeloma. The magnetic resonance examinations of the thoracolumbar spine in 24 patients with newly diagnosed monoclonal gammopathies of unknown significance were compared with those performed in 44 patients with newly diagnosed nontreated multiple myeloma. All findings on magnetic resonance examination performed in patients with monoclonal gammopathies of unknown significance were normal, whereas findings on 38 (86%) of the 44 magnetic resonance examinations performed in patients with multiple myeloma were abnormal. Magnetic resonance imaging can be considered as an additional diagnostic tool in differentiating between monoclonal gammopathies of unknown significance and multiple myeloma, which may be helpful when routine criteria are not sufficient. An abnormal finding on magnetic resonance examination in a patient with monoclonal gammopathies of unknown significance should suggest the diagnosis of multiple myeloma after other causes of marrow signal abnormalities are excluded. Magnetic resonance imaging also may be proposed in the long-term follow-up of monoclonal gammopathies of unknown significance when a new biologic or clinical event suggests the diagnosis of malignant monoclonal gammopathy.
Jaite, Charlotte; Bachmann, Christian; Dewey, Marc; Weschke, Bernhard; Spors, Birgit; von Moers, Arpad; Napp, Adriane; Lehmkuhl, Ulrike; Kappel, Viola
2013-11-01
Numerous research centres apply magnetic resonance imaging (MRI) for research purposes in children. In view of this practical research, ethical concerns regarding the strains the study participants are exposed to during the MRI examination are discussed. The study evaluates whether an MRI examination induces negative emotions in children and adolescents which are more intense than the ones caused by electroencephalography (EEG), an examination method currently classified as causing "minimal stress." Furthermore, the emotional stress induced by the MRI examination in children and adolescents is compared with that induced in adults. The study gathers data on examination-related emotions in children (age 8-17;11, male and female) who undergo an MRI examination of the cerebrum with a medical indication. The comparison group is a sample of children and adolescents examined with EEG (age 8-17;11, male and female) as well as a sample of adults (age 18-65, male and female) examined with MRI. At present, the study is in the stage of data collection. This article presents the study design of the MRI research project.
Filograna, Laura; Magarelli, Nicola; Leone, Antonio; Guggenberger, Roman; Winklhofer, Sebastian; Thali, Michael John; Bonomo, Lorenzo
2015-09-01
The aim of this ex vivo study was to assess the performance of monoenergetic dual-energy CT (DECT) reconstructions to reduce metal artefacts in bodies with orthopedic devices in comparison with standard single-energy CT (SECT) examinations in forensic imaging. Forensic and clinical impacts of this study are also discussed. Thirty metallic implants in 20 consecutive cadavers with metallic implants underwent both SECT and DECT with a clinically suitable scanning protocol. Extrapolated monoenergetic DECT images at 64, 69, 88, 105, 120, and 130 keV and individually adjusted monoenergy for optimized image quality (OPTkeV) were generated. Image quality of the seven monoenergetic images and of the corresponding SECT image was assessed qualitatively and quantitatively by visual rating and measurements of attenuation changes induced by streak artefact. Qualitative and quantitative analyses showed statistically significant differences between monoenergetic DECT extrapolated images and SECT, with improvements in diagnostic assessment in monoenergetic DECT at higher monoenergies. The mean value of OPTkeV was 137.6 ± 4.9 with a range of 130 to 148 keV. This study demonstrates that monoenergetic DECT images extrapolated at high energy levels significantly reduce metallic artefacts from orthopedic implants and improve image quality compared to SECT examination in forensic imaging.
Felix, Rafael Perdomo; Shinkai, Rosemary Sadami Arai; Rockenbach, Maria Ivete Bolzan
2018-01-01
The aim of this study was to analyze the influence of dental implants on the radiographic density of the peri-implant region in tomographic and radiographic examinations. A sample of 21 dental implants from 10 patients with Brånemark-protocol prostheses was evaluated based on postoperative control images, including periapical radiography (paralleling technique), panoramic radiography, and cone beam computed tomography (CBCT). The density means of 6 defined areas near dental implants were calculated and compared considering their locations and the different imaging examinations. The CBCT examinations showed significantly different densities among the measured areas (P < 0.001), while there were no significant differences among the density means of the various areas in periapical radiographs (P = 0.430) and panoramic radiographs (P = 0.149). The highest mean densities were observed in areas closer to the implants in all the examinations: CBCT (127.88 and 120.71), panoramic (106.51 and 106.09), and periapical (120.32). The sagittal CBCT images were measured in 2 different sections, and in both sections those areas closer to implants showed mean densities that were significantly higher than means from more distant areas (P < 0.001). Means from distant areas on CBCT slice imaging were significantly lower than the densities of the same areas on periapical and panoramic examinations. The changes in mean radiographic density values in the peri-implant region confirmed the interference of dental implants in radiographic and tomographic images. CBCT images suffered the greatest interference from dental implants.
Lanzieri, Nicholas; Cook, Brian J
2013-03-01
Previous content analyses of magazine images have typically examined within genres but failed to include comparisons between publications intended for various populations. The purpose of this study was to examine depictions of muscularity and thinness of male images in several widely distributed magazines that target male audiences from a variety of genres. Twenty-three magazine titles with the highest circulation rates that targeted heterosexual men, gay men, and general audiences were selected for image analyses. We found that magazines that target gay male audiences depicted images of men who were thinner in comparison to magazines targeting heterosexual men. Both gay and heterosexual magazines depicted male images with greater muscularity than magazines intended for general audiences. Differences in male image depictions in magazines may contribute to the promotion of an unattainable body ideal in some subgroups of gay culture. Copyright © 2012 Elsevier Ltd. All rights reserved.
Silva, Paolo S; Walia, Saloni; Cavallerano, Jerry D; Sun, Jennifer K; Dunn, Cheri; Bursell, Sven-Erik; Aiello, Lloyd M; Aiello, Lloyd Paul
2012-09-01
To compare agreement between diagnosis of clinical level of diabetic retinopathy (DR) and diabetic macular edema (DME) derived from nonmydriatic fundus images using a digital camera back optimized for low-flash image capture (MegaVision) compared with standard seven-field Early Treatment Diabetic Retinopathy Study (ETDRS) photographs and dilated clinical examination. Subject comfort and image acquisition time were also evaluated. In total, 126 eyes from 67 subjects with diabetes underwent Joslin Vision Network nonmydriatic retinal imaging. ETDRS photographs were obtained after pupillary dilation, and fundus examination was performed by a retina specialist. There was near-perfect agreement between MegaVision and ETDRS photographs (κ=0.81, 95% confidence interval [CI] 0.73-0.89) for clinical DR severity levels. Substantial agreement was observed with clinical examination (κ=0.71, 95% CI 0.62-0.80). For DME severity level there was near-perfect agreement with ETDRS photographs (κ=0.92, 95% CI 0.87-0.98) and moderate agreement with clinical examination (κ=0.58, 95% CI 0.46-0.71). The wider MegaVision 45° field led to identification of nonproliferative changes in areas not imaged by the 30° field of ETDRS photos. Field area unique to ETDRS photographs identified proliferative changes not visualized with MegaVision. Mean MegaVision acquisition time was 9:52 min. After imaging, 60% of subjects preferred the MegaVision lower flash settings. When evaluated using a rigorous protocol, images captured using a low-light digital camera compared favorably with ETDRS photography and clinical examination for grading level of DR and DME. Furthermore, these data suggest the importance of more extensive peripheral images and suggest that utilization of wide-field retinal imaging may further improve accuracy of DR assessment.
Grand Images: Exploring Images of Grandparents in Picture Books
ERIC Educational Resources Information Center
Crawford, Patricia A.; Bhattacharya, Sharika
2014-01-01
This exploratory study examined children's picture books as a source of socialization messages, specifically regarding ageism. Thus, the appearances, cultural backgrounds, and roles of grandparent characters were examined in a sample of 220 books published over a 20-year span. Findings indicate that grandparent characters have come to…
Yusof, Mohd Yusmiaidil Putera Mohd; Rahman, Nur Liyana Abdul; Asri, Amiza Aqiela Ahmad; Othman, Noor Ilyani; Wan Mokhtar, Ilham
2017-12-01
This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor (CMOS) intraoral sensor. A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and interobserver agreement was achieved. The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients.
The Effect of Image Quality, Repeated Study, and Assessment Method on Anatomy Learning
ERIC Educational Resources Information Center
Fenesi, Barbara; Mackinnon, Chelsea; Cheng, Lucia; Kim, Joseph A.; Wainman, Bruce C.
2017-01-01
The use of two-dimensional (2D) images is consistently used to prepare anatomy students for handling real specimen. This study examined whether the quality of 2D images is a critical component in anatomy learning. The visual clarity and consistency of 2D anatomical images was systematically manipulated to produce low-quality and high-quality…
ERIC Educational Resources Information Center
Inoue, Yasuhiro
A study examined the relationship between Japanese adolescents' media exposure, images of the United States, and their attitudes towards the United States and its people by surveying Japanese junior high school students. By using cultivation theory, the study hypothesized that an image of a dangerous America would be partly attributed to Japanese…
Self-enhancing effects of exposure to thin-body images.
Joshi, Ramona; Herman, C Peter; Polivy, Janet
2004-04-01
This study examines the effect of thin-body media images on mood, self-esteem, and self-image ratings of restrained and unrestrained eaters. A secondary purpose was to examine whether these effects were influenced by exposure duration. Under the guise of a perception study, participants were exposed to thin-body or control advertisements (e.g., perfume bottles) for either 7 or 150 ms and then completed a questionnaire packet. Restrained eaters reported more favorable self-image and social self-esteem (but not appearance self-esteem) scores after exposure to thin-body images than after exposure to control advertisements. The self-image and social self-esteem scores of unrestrained eaters were unaffected by advertisement type, but their appearance self-esteem scores were lower after exposure to thin-body advertisements. No differences were found for mood ratings and total self-esteem. We discuss restraint status as a moderator of the effects of thin-body images on women's body image. Copyright 2004 by Wiley Periodicals, Inc. Int J Eat Disord 35: 333-341, 2004.
Infrared imaging of cotton fibers using a focal-plane array detector
USDA-ARS?s Scientific Manuscript database
Vibrational spectroscopy studies can be used to examine the quality and structure of cotton fibers. An emerging area of research relates to the imaging of cotton fibers. Herein, we report the use of a Fourier-transform infrared (FTIR) microscope to image developing cotton fibers. Studies were perfor...
Li, Zhijian; Wu, Chengqing; Olayiwola, J Nwando; Hilaire, Daniel St; Huang, John J
2012-02-01
To study the cost benefit analysis of using a telemedicine-based digital retinal imaging evaluation compared to conventional ophthalmologic fundus examination of diabetic patients for diabetic retinopathy. In this study, diabetic patients from Community Health Center, Inc. (CHCI), a large multi-site Federally Qualified Health Center) were evaluated by teleophthalmology using the Canon CR-1 nonmydriatic fundus camera. Digital images were acquired in the CHCI offices and saved on the EyePACS server network. The images were later evaluated by retinal specialists at the Yale Eye Center, Yale University Department of Ophthalmology and Visual Science. The costs for the standard of care ophthalmic examinations were calculated based on 2009 Medicaid reimbursement rates. The process of telemedicine-based diagnosis was based on a take-store-forward-visualize system. The cost of telemedicine-based digital retinal imaging examination included cost for devices, training, annual costs and a transportation fee. Current Medicaid reimbursement, transportation, and staff labor costs were used to calculate the conventional retinal examination cost as a comparison. Among the 611 patients digital retinal images screened in the first year of this program and for whom data are available, 166 (27.2%) cases of diabetic retinopathy were identified. Seventy-five (12.3%) patients screened positive with clinically significant disease and were referred for further ophthalmological evaluation and treatment. The primary direct cost of the telemedicine was $3.80, $15.00, $17.60, $1.50, and $2.50 per patient for medical assistant, ophthalmologist, capital cost (Equipment + Training), equipment maintenance, and transportation fee, respectively. The total cost in the telemedicine-based digital retinal imaging and evaluation was $40.40. The cost of conventional retinal examination was $8.70, $65.30, and $3.80 per patients for round-trip transportation, 2009 national Medicaid Physician Fee Schedule allowable for bilateral eye examination, and medical assistant personnel, respectively. The total costs of conventional fundus examination were $77.80. An additional conventional ophthalmologic retinal examination was required for 75 (12.3%) patients with clinically significant disease on telemedicine evaluation, which involves an averaged additional cost of $ 9.55 per patient for all the patients in the study. If the cost of subsequent examination was added, the total cost of telemedicine-based digital fundus imaging was $49.95 per patient in our group of 611 patients evaluated. Our cost analysis indicates that telemedicine-based diabetic retinopathy screening cost less ($49.95 vs $77.80) than conventional retinal examination and the telemedicine-based digital retinal imaging examination has the potential to provide an alternative method with greater convenience and access for the remote and indigent populations. Diabetes mellitus and diabetic retinopathy are growing problems in the United States and worldwide. Large scale adoption of telemedicine should be encouraged as a means toward providing improved access, increasing compliance with annual evaluation, at a low cost for patients with diabetes with direct access to an eye care specialist.
Diffusion Tensor Imaging: Application to the Study of the Developing Brain
ERIC Educational Resources Information Center
Cascio, Carissa J.; Gerig, Guido; Piven, Joseph
2007-01-01
Objective: To provide an overview of diffusion tensor imaging (DTI) and its application to the study of white matter in the developing brain in both healthy and clinical samples. Method: The development of DTI and its application to brain imaging of white matter tracts is discussed. Forty-eight studies using DTI to examine diffusion properties of…
The image of mathematics held by Irish post-primary students
NASA Astrophysics Data System (ADS)
Lane, Ciara; Stynes, Martin; O'Donoghue, John
2014-08-01
The image of mathematics held by Irish post-primary students was examined and a model for the image found was constructed. Initially, a definition for 'image of mathematics' was adopted with image of mathematics hypothesized as comprising attitudes, beliefs, self-concept, motivation, emotions and past experiences of mathematics. Research focused on students studying ordinary level mathematics for the Irish Leaving Certificate examination - the final examination for students in second-level or post-primary education. Students were aged between 15 and 18 years. A questionnaire was constructed with both quantitative and qualitative aspects. The questionnaire survey was completed by 356 post-primary students. Responses were analysed quantitatively using Statistical Package for the Social Sciences (SPSS) and qualitatively using the constant comparative method of analysis and by reviewing individual responses. Findings provide an insight into Irish post-primary students' images of mathematics and offer a means for constructing a theoretical model of image of mathematics which could be beneficial for future research.
Supplementary value of functional imaging in forensic medicine.
Mirzaei, Siroos; Sonneck-Koenne, Charlotte; Bruecke, Thomas; Aryana, Kamran; Knoll, Peter; Zakavi, Rasoul
2012-01-01
The aim of this study is to evaluate the role of functional imaging for forensic purposes. We reviewed a few outpatient cases that were sent to our department for examination after traumatic events and one case with neuropsychic disturbances. Functional imaging showed signs of traumatic lesions in the skeletal system, of brain metabolism and of renal failure. Functional disturbances following traumatic events are in some cases more important than morphological abnormalities. Targeted scintigraphic examinations could be applied for visualisation of traumatic lesions or evaluation of functional disturbances caused by traumatic events. These examinations can be used as evidence in the courtroom.
Lin, Chu-Hsu; Tsai, Yuan-Hsiung; Chang, Chia-Hao; Chen, Chien-Min; Hsu, Hung-Chih; Wu, Chun-Yen; Hong, Chang-Zern
2013-09-01
The aims of this study were to investigate the correlation of the findings of multiple median and ulnar F-wave variables and magnetic resonance imaging examinations in the prediction of cervical radiculopathy. The data of 68 patients who underwent both nerve conduction studies of the upper extremities and cervical spine magnetic resonance imaging within 3 mos of the nerve conduction studies were retrospectively reviewed and reinterpreted. The associations between multiple median and ulnar F-wave variables (including persistence, chronodispersion, and minimal, maximal, and mean latencies) and magnetic resonance imaging evidence of lower cervical spondylotic radiculopathy (i.e., C7, C8, and T1 radiculopathy) were investigated. Patients with lower cervical radiculopathy exhibited reduced right median F-wave persistence (P = 0.011), increased right ulnar F-wave chronodispersion (P = 0.041), and a trend toward increased left ulnar F-wave chronodispersion (P = 0.059); however, there were no other consistent significant differences in the F-wave variables between patients with and patients without magnetic resonance imaging evidence of lower cervical radiculopathy. In comparison with normal reference values established previously, the sensitivity and positive predictive value of F-wave variable abnormalities for predicting lower cervical radiculopathy were low. There was a low correlation between F-wave studies and magnetic resonance imaging examinations. The diagnostic utility of multiple F-wave variables in the prediction of cervical radiculopathy was not supported by this study.
NASA Astrophysics Data System (ADS)
Zhong, Hui-Qing; Zeng, Chang-Chun; Guo, Zhou-Yi; He, Yong-Hong; Wang, Rui-Kang; Liu, Song-Hao
2007-05-01
Inspection of tongue is an age-old technique used by Traditional Chinese Medicine (TCM) practitioners to determine a patient's health status. Because tongue examination is a subjective and inaccurate diagnostic method, a scientific tool which can provide objective and accurate information is needed to assist the TCM practitioners in their practice. The purpose of the study was to examine the feasibility of developing a glossoscopy from an optical coherence tomography (OCT) imaging system. In the present study, an OCT system was used to examine the tongue of the rat. After examination, the tongue was surgically removed, sectioned by a microtome and put on a glass slide for histological examination. The slides were examined under a bright-field microscope. Results of the OCT imaging studies showed that the OCT system was capable of showing the images of three distinct regions of the tongue: the tongue coating layers, the interface between the tongue coating and the tongue body, and the tongue body. It was also possible to assign an index number to each of the coating layers. When the tongue tissue was examined under a microscope, three separate regions of the tongue also were visible. Results of this pilot study shows that the OCT potentially can be developed into a glossoscopy for clinical application in TCM practice.
Outside CT imaging among emergency department transfer patients.
Sung, Jeffrey C; Sodickson, Aaron; Ledbetter, Stephen
2009-09-01
The aim of this study was to characterize the quantity and types of outside computed tomographic (CT) examinations submitted for reinterpretation among emergency department (ED) transfers to a tertiary care, level I trauma, academic medical center and the frequency of and reasons for repeat imaging. Reinterpretation requests for outside CT studies accompanying ED transfer patients over a 4-month period were prospectively audited. Clinicians completed forms specifying type of CT study, outside report availability, interpretational discrepancies, repeat imaging requests, and reasons for repeat imaging. A total of 425 CT studies were reviewed among 255 transfer patients, with a mean of 2.8 examinations (range, 0-16) on 1.7 patients (range, 0-8) per day. The patients' mean age was 59 years, and 57% were male. The clinicians reported no outside verbal or written reports for 16% of patients. Interpretational discrepancies were noted in 12% of those with outside reports. Repeat scans might have been avoided in as many as 25% of rescanned patients (35% of repeat examinations) because they were performed solely for imaging or information technology reasons (inadequate imaging, compact disc inoperability, or unavailable images within the hospital's picture archiving and communication system). Rescanned trauma patients in particular had a high per patient rate (32%) of potentially avoidable reasons, with a lower rate (11%) in nontrauma patients. Outside CT imaging in ED transfers adds workload and resource requirements for receiving institutions. A communication gap exists between transferring and receiving institutions, and interpretational discrepancies are common. Process improvement measures are suggested that might reduce the substantial rates of potentially avoidable reimaging.
Effect of film-based versus filmless operation on the productivity of CT technologists.
Reiner, B I; Siegel, E L; Hooper, F J; Glasser, D
1998-05-01
To determine the relative time required for a technologist to perform a computed tomographic (CT) examination in a "filmless" versus a film-based environment. Time-motion studies were performed in 204 consecutive CT examinations. Images from 96 examinations were electronically transferred to a picture archiving and communication system (PACS) without being printed to film, and 108 were printed to film. The time required to obtain and electronically transfer the images or print the images to film and make the current and previous studies available to the radiologists for interpretation was recorded. The time required for a technologist to complete a CT examination was reduced by 45% with direct image transfer to the PACS compared with the time required in the film-based mode. This reduction was due to the elimination of a number of steps in the filming process, such as the printing at multiple window or level settings. The use of a PACS can result in the elimination of multiple time-intensive tasks for the CT technologist, resulting in a marked reduction in examination time. This reduction can result in increased productivity, and, hence greater cost-effectiveness with filmless operation.
Perceptual expertise in forensic facial image comparison.
White, David; Phillips, P Jonathon; Hahn, Carina A; Hill, Matthew; O'Toole, Alice J
2015-09-07
Forensic facial identification examiners are required to match the identity of faces in images that vary substantially, owing to changes in viewing conditions and in a person's appearance. These identifications affect the course and outcome of criminal investigations and convictions. Despite calls for research on sources of human error in forensic examination, existing scientific knowledge of face matching accuracy is based, almost exclusively, on people without formal training. Here, we administered three challenging face matching tests to a group of forensic examiners with many years' experience of comparing face images for law enforcement and government agencies. Examiners outperformed untrained participants and computer algorithms, thereby providing the first evidence that these examiners are experts at this task. Notably, computationally fusing responses of multiple experts produced near-perfect performance. Results also revealed qualitative differences between expert and non-expert performance. First, examiners' superiority was greatest at longer exposure durations, suggestive of more entailed comparison in forensic examiners. Second, experts were less impaired by image inversion than non-expert students, contrasting with face memory studies that show larger face inversion effects in high performers. We conclude that expertise in matching identity across unfamiliar face images is supported by processes that differ qualitatively from those supporting memory for individual faces. © 2015 The Author(s).
Samah, Asnarulkhadi Abu; Ahmadian, Maryam
2014-01-01
This study aimed to examine the relationship between body image satisfaction and breast self-screening behavior and intentions. The sample for this cross-sectional study consisted of 842 female university students who were recruited from a number of public and private universities. Data were obtained between the months of November and December, 2013, using multistage random cluster sampling. Main research variables were breast cancer screening behavior and intentions, demographic factors, and the total scores on each of the Multidimensional Body-Self Relations Questionnaire (MBSRQ-Appearance Scales) subscales. Results of multivariate analysis showed that having higher satisfaction and more positive evaluation of appearance were related to having performed breast self-examination more frequently in the last year and intending to perform breast self-examination more frequently in the next year. Longitudinal research can potentially provide detailed information about overall body image satisfaction and breast cancer screening behavior among various communities.
The purpose of this Work Assignment, 02-03, is to examine the feasibility of collecting transmitting, and analyzing 3-D ultrasound data in the context of a multi-center study of pregnant women. The study will also examine the reliability of measurements obtained from 3-D images< ...
Optical imaging for breast cancer prescreening
Godavarty, Anuradha; Rodriguez, Suset; Jung, Young-Jin; Gonzalez, Stephanie
2015-01-01
Breast cancer prescreening is carried out prior to the gold standard screening using X-ray mammography and/or ultrasound. Prescreening is typically carried out using clinical breast examination (CBE) or self-breast examinations (SBEs). Since CBE and SBE have high false-positive rates, there is a need for a low-cost, noninvasive, non-radiative, and portable imaging modality that can be used as a prescreening tool to complement CBE/SBE. This review focuses on the various hand-held optical imaging devices that have been developed and applied toward early-stage breast cancer detection or as a prescreening tool via phantom, in vivo, and breast cancer imaging studies. Apart from the various optical devices developed by different research groups, a wide-field fiber-free near-infrared optical scanner has been developed for transillumination-based breast imaging in our Optical Imaging Laboratory. Preliminary in vivo studies on normal breast tissues, with absorption-contrasted targets placed in the intramammary fold, detected targets as deep as 8.8 cm. Future work involves in vivo imaging studies on breast cancer subjects and comparison with the gold standard X-ray mammography approach. PMID:26229503
Examining the Perceptions of Brand Images Regarding Competing MBA Programs
ERIC Educational Resources Information Center
Hinds, Timothee; Falgoust, Dexter; Thomas, Kerry, Jr.; Budden, Michael C.
2010-01-01
In today's economic environment, it is crucial to create a strong, consistent brand image within a graduate business program. This study examines the perceptions that students at Southeastern Louisiana University hold about its MBA program and the MBA programs of its main competitors. A focus group was conducted to identify competitors and factors…
Perceptions and Images of North Africa: What American Schools Teach.
ERIC Educational Resources Information Center
Robinson, Victoria
2002-01-01
Examined descriptions of North Africa (particularly Tunisia) found in U.S. high school social studies textbooks, noting the resulting perceptions and images these descriptions created in the minds of teachers and students. Data from examination of textbooks and interviews with teachers indicated that few high school students were exposed to images…
Larsson, Joel; Båth, Magnus; Ledenius, Kerstin; Caisander, Håkan; Thilander-Klang, Anne
2016-06-01
The purpose of this study was to investigate the effect of different combinations of convolution kernel and the level of Adaptive Statistical iterative Reconstruction (ASiR™) on diagnostic image quality as well as visualisation of anatomical structures in paediatric abdominal computed tomography (CT) examinations. Thirty-five paediatric patients with abdominal pain with non-specified pathology undergoing abdominal CT were included in the study. Transaxial stacks of 5-mm-thick images were retrospectively reconstructed at various ASiR levels, in combination with three convolution kernels. Four paediatric radiologists rated the diagnostic image quality and the delineation of six anatomical structures in a blinded randomised visual grading study. Image quality at a given ASiR level was found to be dependent on the kernel, and a more edge-enhancing kernel benefitted from a higher ASiR level. An ASiR level of 70 % together with the Soft™ or Standard™ kernel was suggested to be the optimal combination for paediatric abdominal CT examinations. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Using Perfusion fMRI to Measure Continuous Changes in Neural Activity with Learning
ERIC Educational Resources Information Center
Olson, Ingrid R.; Rao, Hengyi; Moore, Katherine Sledge; Wang, Jiongjiong; Detre, John A.; Aguirre, Geoffrey K.
2006-01-01
In this study, we examine the suitability of a relatively new imaging technique, "arterial spin labeled perfusion imaging," for the study of continuous, gradual changes in neural activity. Unlike BOLD imaging, the perfusion signal is stable over long time-scales, allowing for accurate assessment of continuous performance. In addition, perfusion…
Is airport baggage inspection just another medical image?
NASA Astrophysics Data System (ADS)
Gale, Alastair G.; Mugglestone, Mark D.; Purdy, Kevin J.; McClumpha, A.
2000-04-01
A similar inspection situation to medical imaging appears to be that of the airport security screener who examines X-ray images of passenger baggage. There is, however, little research overlap between the two areas. Studies of observer performance in examining medical images have led to a conceptual model which has been used successfully to understand diagnostic errors and develop appropriate training strategies. The model stresses three processes of; visual search, detection of potential targets, and interpretation of these areas; with most errors being due to the latter two factors. An initial study is reported on baggage inspection, using several brief image presentations, to examine the applicability of such a medical model to this domain. The task selected was the identification of potential Improvised Explosive Devices (IEDs). Specifically investigated was the visual search behavior of inspectors. It was found that IEDs could be identified in a very brief image presentation, with increased presentation time this performance improved. Participants fixated on IEDs very early on and sometimes concentrated wholly on this part of the baggage display. When IEDs were missed this was mainly due to interpretative factors rather than visual search or IED detection. It is argued that the observer model can be applied successfully to this scenario.
Rahman, Nur Liyana Abdul; Asri, Amiza Aqiela Ahmad; Othman, Noor Ilyani; Wan Mokhtar, Ilham
2017-01-01
Purpose This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor (CMOS) intraoral sensor. Materials and Methods A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. Results The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and interobserver agreement was achieved. Conclusion The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients. PMID:29279822
ERIC Educational Resources Information Center
Smolík, Filip; Kríž, Adam
2015-01-01
Imageability is the ability of words to elicit mental sensory images of their referents. Recent research has suggested that imageability facilitates the processing and acquisition of inflected word forms. The present study examined whether inflected word forms are acquired earlier in highly imageable words in Czech children. Parents of 317…
Yagahara, Ayako; Yokooka, Yuki; Jiang, Guoqian; Tsuji, Shintarou; Fukuda, Akihisa; Nishimoto, Naoki; Kurowarabi, Kunio; Ogasawara, Katsuhiko
2018-03-01
Describing complex mammography examination processes is important for improving the quality of mammograms. It is often difficult for experienced radiologic technologists to explain the process because their techniques depend on their experience and intuition. In our previous study, we analyzed the process using a new bottom-up hierarchical task analysis and identified key components of the process. Leveraging the results of the previous study, the purpose of this study was to construct a mammographic examination process ontology to formally describe the relationships between the process and image evaluation criteria to improve the quality of mammograms. First, we identified and created root classes: task, plan, and clinical image evaluation (CIE). Second, we described an "is-a" relation referring to the result of the previous study and the structure of the CIE. Third, the procedural steps in the ontology were described using the new properties: "isPerformedBefore," "isPerformedAfter," and "isPerformedAfterIfNecessary." Finally, the relationships between tasks and CIEs were described using the "isAffectedBy" property to represent the influence of the process on image quality. In total, there were 219 classes in the ontology. By introducing new properties related to the process flow, a sophisticated mammography examination process could be visualized. In relationships between tasks and CIEs, it became clear that the tasks affecting the evaluation criteria related to positioning were greater in number than those for image quality. We developed a mammographic examination process ontology that makes knowledge explicit for a comprehensive mammography process. Our research will support education and help promote knowledge sharing about mammography examination expertise.
Usefulness of biological fingerprint in magnetic resonance imaging for patient verification.
Ueda, Yasuyuki; Morishita, Junji; Kudomi, Shohei; Ueda, Katsuhiko
2016-09-01
The purpose of our study is to investigate the feasibility of automated patient verification using multi-planar reconstruction (MPR) images generated from three-dimensional magnetic resonance (MR) imaging of the brain. Several anatomy-related MPR images generated from three-dimensional fast scout scan of each MR examination were used as biological fingerprint images in this study. The database of this study consisted of 730 temporal pairs of MR examination of the brain. We calculated the correlation value between current and prior biological fingerprint images of the same patient and also all combinations of two images for different patients to evaluate the effectiveness of our method for patient verification. The best performance of our system were as follows: a half-total error rate of 1.59 % with a false acceptance rate of 0.023 % and a false rejection rate of 3.15 %, an equal error rate of 1.37 %, and a rank-one identification rate of 98.6 %. Our method makes it possible to verify the identity of the patient using only some existing medical images without the addition of incidental equipment. Also, our method will contribute to patient misidentification error management caused by human errors.
Axial nonimaging characteristics of imaging lenses: discussion.
Siew, Ronian
2016-05-01
At observation planes away from the image plane, an imaging lens is a nonimaging optic. We examine the variation of axial irradiance with distance in image space and highlight the following little-known observation for discussion: On a per-unit-area basis, the position of the highest concentration in image space is generally not at the focal plane. This characteristic is contrary to common experience, and it offers an additional degree of freedom for the design of detection systems. Additionally, it would also apply to lenses with negative refractive index. The position of peak concentration and its irradiance is dependent upon the location and irradiance of the image. As such, this discussion also includes a close examination of expressions for image irradiance and explains how they are related to irradiance calculations beyond the image plane. This study is restricted to rotationally symmetric refractive imaging systems with incoherent extended Lambertian sources.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramanna, L.; Tashkin, D.P.; Taplin, G.V.
1975-11-01
Seventy subjects with either no, mild, or definite evidence of pulmonary abnormality on screening studies volunteered to have detailed pulmonary function tests (PFTs), respiratory questionnaires, physical examinations, and /sup 113m/indium aerosol-inhalation lung imaging performed. Also, 22 and 52 of these subjects underwent /sup 133/xenon ventilation and lung perfusion imaging with /sup 99m/technetium-labelled macroaggregated albumin, and 56 had chest x-ray examinations performed. Results of the radionuclide lung-imaging procedures were compared with those of conventional PFTs and other clinical diagnostic procedures used to identify chronic obstructive pulmonary disease (COPD). Abnormal radioaerosol patterns were found in 32 of 33 subjects with abnormal findingsmore » on PFTs, whereas results of PFTs were abnormal in only 32 of 46 subjects with abnormal aerosol deposition. Aerosol lung images were abnormal more frequently than respiratory questionnaire responses, findings on physical examination, chest x-ray films, and perfusion lung images and with approximately the same frequency as /sup 133/xenon ventilation scintiscans. These results suggest that radioaerosol lung imaging may be a more sensitive indicator of early COPD than other diagnostic procedures, including maximal midexpiratory flow rates, single-breath nitrogen washout, and closing volume. Further studies are required to determine the physiologic and pathologic significance of isolated aerosol lung-imaging abnormalities.« less
Lo, Glen; Scaranelo, Anabel M; Aboras, Hana; Ghai, Sandeep; Kulkarni, Supriya; Fleming, Rachel; Bukhanov, Karina; Crystal, Pavel
2017-10-01
Purpose To evaluate the value of mammography in detecting breast cancer in high-risk women undergoing screening breast magnetic resonance (MR) imaging. Materials and Methods An ethics-approved, retrospective review of prospective databases was performed to identify outcomes of 3934 screening studies (1977 screening MR imaging examinations and 1957 screening mammograms) performed between January 2012 and July 2014 in 1249 high-risk women. Performance measures including recall and cancer detection rates, sensitivity, specificity, and positive predictive values were calculated for both mammography and MR imaging. Results A total of 45 cancers (33 invasive and 12 ductal carcinomas in situ) were diagnosed, 43 were seen with MR imaging and 14 with both mammography and MR imaging. Additional tests (further imaging and/or biopsy) were recommended in 461 screening MR imaging studies (recall rate, 23.3%; 95% confidence interval [CI]: 21.5%, 25.2%), and mammography recalled 217 (recall rate, 11.1%; 95% CI: 9.7%, 12.6%). The cancer detection rate for MR imaging was 21.8 cancers per 1000 examinations (95% CI: 15.78, 29.19) and that for mammography was 7.2 cancers per 1000 examinations (95% CI: 3.92, 11.97; P < .001). Sensitivity and specificity of MR imaging were 96% and 78% respectively, and those of mammography were 31% and 89%, respectively (P < .001). Positive predictive value for MR imaging recalls was 9.3% (95% CI: 6.83%, 12.36%) and that for mammography recalls was 6.5% (95% CI: 3.57%, 10.59%). Conclusion Contemporaneous screening mammography did not have added value in detection of breast cancer for women who undergo screening MR imaging. Routine use of screening mammography in women undergoing screening breast MR imaging warrants reconsideration. © RSNA, 2017 Online supplemental material is available for this article.
Measuring the Pain Area: An Intra- and Inter-Rater Reliability Study Using Image Analysis Software.
Dos Reis, Felipe Jose Jandre; de Barros E Silva, Veronica; de Lucena, Raphaela Nunes; Mendes Cardoso, Bruno Alexandre; Nogueira, Leandro Calazans
2016-01-01
Pain drawings have frequently been used for clinical information and research. The aim of this study was to investigate intra- and inter-rater reliability of area measurements performed on pain drawings. Our secondary objective was to verify the reliability when using computers with different screen sizes, both with and without mouse hardware. Pain drawings were completed by patients with chronic neck pain or neck-shoulder-arm pain. Four independent examiners participated in the study. Examiners A and B used the same computer with a 16-inch screen and wired mouse hardware. Examiner C used a notebook with a 16-inch screen and no mouse hardware, and Examiner D used a computer with an 11.6-inch screen and a wireless mouse. Image measurements were obtained using GIMP and NIH ImageJ computer programs. The length of all the images was measured using GIMP software to a set scale in ImageJ. Thus, each marked area was encircled and the total surface area (cm(2) ) was calculated for each pain drawing measurement. A total of 117 areas were identified and 52 pain drawings were analyzed. The intrarater reliability between all examiners was high (ICC = 0.989). The inter-rater reliability was also high. No significant differences were observed when using different screen sizes or when using or not using the mouse hardware. This suggests that the precision of these measurements is acceptable for the use of this method as a measurement tool in clinical practice and research. © 2014 World Institute of Pain.
Wei, C P; Hu, P J; Sheng, O R
2001-03-01
When performing primary reading on a newly taken radiological examination, a radiologist often needs to reference relevant prior images of the same patient for confirmation or comparison purposes. Support of such image references is of clinical importance and may have significant effects on radiologists' examination reading efficiency, service quality, and work satisfaction. To effectively support such image reference needs, we proposed and developed a knowledge-based patient image pre-fetching system, addressing several challenging requirements of the application that include representation and learning of image reference heuristics and management of data-intensive knowledge inferencing. Moreover, the system demands an extensible and maintainable architecture design capable of effectively adapting to a dynamic environment characterized by heterogeneous and autonomous data source systems. In this paper, we developed a synthesized object-oriented entity- relationship model, a conceptual model appropriate for representing radiologists' prior image reference heuristics that are heuristic oriented and data intensive. We detailed the system architecture and design of the knowledge-based patient image pre-fetching system. Our architecture design is based on a client-mediator-server framework, capable of coping with a dynamic environment characterized by distributed, heterogeneous, and highly autonomous data source systems. To adapt to changes in radiologists' patient prior image reference heuristics, ID3-based multidecision-tree induction and CN2-based multidecision induction learning techniques were developed and evaluated. Experimentally, we examined effects of the pre-fetching system we created on radiologists' examination readings. Preliminary results show that the knowledge-based patient image pre-fetching system more accurately supports radiologists' patient prior image reference needs than the current practice adopted at the study site and that radiologists may become more efficient, consultatively effective, and better satisfied when supported by the pre-fetching system than when relying on the study site's pre-fetching practice.
Rawle, Marnie; Oliver, Tanya; Pighills, Alison; Lindsay, Daniel
2017-12-01
X-ray Operator (XO) supervision in Queensland is performed by radiographers in a site removed from the XO site. This has historically been performed by telephone when the XO requires immediate help, as well as post-examination through radiographer review and the provision of written feedback on images produced. This project aimed to improve image quality through the provision of real-time support of XOs by the introduction of video conference (VC) supervision. A 6-month pilot project compared image quality with and without VC supervision. VC equipment was installed in the X-ray room at two rural sites, as well as at the radiographer site, to enable visual and oral supervision. The VC unit enabled visualisation of the X-ray examination technique as it was being undertaken, as well as the images produced prior to transmission to the Picture Archiving and Communication System (PACS). Statistically significant improvement in image quality criteria measures were seen for patient positioning (P = 0.008), image quality (P < 0.001) and diagnostic value (P < 0.001) of images taken during this project. No statistically significant differences were seen during case level assessment in the inclusion of only appropriate imaging (P = 0.06), and the inclusion of unacceptable imaging (P = 0.06), however improvements were seen in both of these criteria. The survey revealed 24.6% of examinations performed would normally have involved the XO contacting the radiographer for assistance, although, assistance was actually provided in 88.3% of examinations. This project has demonstrated that significant improvement in image quality is achievable with VC supervision. A larger study with a control arm that did not receive direct supervision should be used to validate the findings of this study. © 2017 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.
Lo Re, Giuseppe; De Luca, Rossella; Muscarneri, Filippa; Dorangricchia, Patrizia; Picone, Dario; Vernuccio, Federica; Salerno, Sergio; La Tona, Giuseppe; Pinto, Antonio; Midiri, Massimo; Russo, Antonio; Lagalla, Roberto; Cicero, Giuseppe
2016-10-01
Every patient could feel anxious when he waits in a radiological department to undergo diagnostic exams. The aim of our study is to evaluate the impact of the radiological exams on patient anxiety. We evaluated 343 patients (mean age 54.83 years) who underwent different types of diagnostic exams in the Department of Diagnostic Imaging at our Hospital from April 2013 to August 2014. We administered to patients the State and Trait Anxiety Inventory Test, which detected with high sensitivity both state anxiety and trait anxiety. A team of clinical psychologists and radiologists evaluated the scores obtained. 83 out of 343 patients were excluded because refused to file the questionnaire. 31 % of the patients were submitted to MR, 18 % to breast imaging, 10 % to X-ray, 22 % Computer Tomography and 19 % to ultrasound, as previously described. 41 % of patients were submitted to the examination because of an oncologic disease, while 59 % because of non-oncological disease. Therefore, it was found that high levels of anxiety were present in most (about 91 %) of the patients and the scores varied according to the imaging examination and to the examination's reason: anxiety level was higher in non-oncological patients (54 %) and in patients waiting to undergo to MRI exams (29 %). Our data suggest that the diagnostic exams are stressful events for the patient, also in non-oncological patients. So, it is important to adequate the radiological staff to receive the patient, to inform him and perform exams with emotive involvement with a targeted education. Also, further studies are needed to evaluate the anxiety level and the quality of the images, because the anxiety can result in a somatic disorder with hyperactivity of the autonomic nervous system which may affect the patient's physical examination, causing problems in the evaluation of radiological images making to non-cooperative patient. MRI imaging is the examination that more of all led to an anxious state of patients but the main stressor is not related to the type of diagnostic examination, but to the uncertainty of the diagnosis, therapy and prognosis.
Poulsen, Liv la Cour; Bækgaard, Emilie Stokholm; Istre, Per Grosen; Schmidt, Thomas Andersen; Larsen, Torben
2015-01-01
Purpose Ultrasonography is a noninvasive, cheap, and fast way of assessing abdominal pain in an emergency department. Many physicians working in emergency departments do not have pre-existing ultrasound experience. The purpose of this study was to investigate the ability of first-year internship doctors to perform a reliable ultrasound examination on patients with abdominal pain in an emergency setting. Materials and methods This study took place in an emergency department in Denmark. Following a 1-day ultrasound introduction course, three doctors without prior ultrasound experience scanned 45 patients during a 2-month period. The applicability of the examinations was evaluated by subsequent control examination: computed tomography, operation, or ultrasound by a trained radiologist or gynecologist or, in cases where the patient was immediately discharged, by ultrasound image evaluation. Results In 14 out of 21 patients with a control examination, there was diagnostic agreement between the project ultrasound examination and the control. Image evaluation of all patients showed useful images of the gallbladder, kidneys, liver, abdominal aorta, and urinary bladder, but no useful images for either the pancreas or colon. Conclusion With only little formal training, it is possible for first-year internship doctors to correctly visualize some abdominal organs with ultrasonography. However, a longer study time frame, including more patients, and an ultrasound course specifically designed for the purpose of use in an emergency department, is needed to enhance the results. PMID:27147884
Predictors of Change in Body Image in Female Participants of an Outdoor Education Program
ERIC Educational Resources Information Center
Hovey, Kate; Foland, Jody; Foley, John T.; Kniffin, Mike; Bailey, JoEllen
2016-01-01
Body image is an ever-changing phenomenon that has a profound effect on women's quality of life. Research related to body image is expansive, but few researchers have focused on how outdoor education may influence body image. This study examines predictors of change in body image of female participants of an outdoor education program. Twenty-eight…
Medical Imaging Field of Magnetic Resonance Imaging: Identification of Specialties within the Field
ERIC Educational Resources Information Center
Grey, Michael L.
2009-01-01
This study was conducted to determine if specialty areas are emerging in the magnetic resonance imaging (MRI) profession due to advancements made in the medical sciences, imaging technology, and clinical applications used in MRI that would require new developments in education/training programs and national registry examinations. In this…
ERIC Educational Resources Information Center
Bedny, Marina; Thompson-Schill, Sharon L.
2006-01-01
The present study characterizes the neural correlates of noun and verb imageability and addresses the question of whether components of the neural network supporting word recognition can be separately modified by variations in grammatical class and imageability. We examined the effect of imageability on BOLD signal during single-word comprehension…
Body Image Satisfaction among Blacks
ERIC Educational Resources Information Center
Gustat, Jeanette; Carton, Thomas W.; Shahien, Amir A.; Andersen, Lori
2017-01-01
Satisfaction with body image is a factor related to health outcomes. The purpose of this study is to examine the relationship between body image satisfaction and body size perception in an urban, Black community sample in New Orleans, Louisiana. Only 42.2% of respondents were satisfied with their body image and 44.1% correctly perceived their body…
ERIC Educational Resources Information Center
Kobayashi, Megumi; Otsuka, Yumiko; Nakato, Emi; Kanazawa, So; Yamaguchi, Masami K.; Kakigi, Ryusuke
2012-01-01
Arcimboldo images induce the perception of faces when shown upright despite the fact that only nonfacial objects such as vegetables and fruits are painted. In the current study, we examined whether infants recognize a face in the Arcimboldo images by using the preferential looking technique and near-infrared spectroscopy (NIRS). In the first…
Final Report 2007: DOE-FG02-87ER60561
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kilbourn, Michael R
2007-04-26
This project involved a multi-faceted approach to the improvement of techniques used in Positron Emission Tomography (PET), from radiochemistry to image processing and data analysis. New methods for radiochemical syntheses were examined, new radiochemicals prepared for evaluation and eventual use in human PET studies, and new pre-clinical methods examined for validation of biochemical parameters in animal studies. The value of small animal PET imaging in measuring small changes of in vivo biochemistry was examined and directly compared to traditional tissue sampling techniques. In human imaging studies, the ability to perform single experimental sessions utilizing two overlapping injections of radiopharmaceuticals wasmore » tested, and it was shown that valid biochemical measures for both radiotracers can be obtained through careful pharmacokinetic modeling of the PET emission data. Finally, improvements in reconstruction algorithms for PET data from small animal PET scanners was realized and these have been implemented in commercial releases. Together, the project represented an integrated effort to improve and extend all basic science aspects of PET imaging at both the animal and human level.« less
Pre-Processes for Urban Areas Detection in SAR Images
NASA Astrophysics Data System (ADS)
Altay Açar, S.; Bayır, Ş.
2017-11-01
In this study, pre-processes for urban areas detection in synthetic aperture radar (SAR) images are examined. These pre-processes are image smoothing, thresholding and white coloured regions determination. Image smoothing is carried out to remove noises then thresholding is applied to obtain binary image. Finally, candidate urban areas are detected by using white coloured regions determination. All pre-processes are applied by utilizing the developed software. Two different SAR images which are acquired by TerraSAR-X are used in experimental study. Obtained results are shown visually.
Chan, Keith T; Carroll, Tamara; Linnau, Ken F; Lehnert, Bruce
2015-11-01
Imaging report turnaround time (RTAT) is an important measure of radiology performance and has become the leading priority in customer satisfaction surveys conducted among nonradiologists, who may not be familiar with the imaging workflow. Our aim was to assess physicians' expected RTAT for commonly ordered studies and determine if satisfaction correlates with met expectations. Retrospective review of inpatient imaging was conducted at a single academic institution, and RTAT for 18,414 studies was calculated. Examinations were grouped by study type, priority, and time of day. A cross-sectional survey instrument was completed by 48 internal medicine and surgery resident physicians with questions regarding RTAT and their level of satisfaction with various examinations. Actual RTAT ranged from 1.6 to 26.0 hours, with chest radiographs and computed tomographies generally faster than magnetic resonance images and ultrasounds. Urgent (STAT) examinations and those ordered during business hours have shorter RTAT. The time for image interpretation largely contributed to the RTAT because of the lack of night-time radiology coverage. Referring physician expectations were consistently shorter than actual RTAT, ranging from 30 minutes to 24 hours. Overall satisfaction scores were inversely correlated with RTAT, with a strong correlation to the time from study order to imaging (r(2) = 0.63) and a weak correlation to the image interpretation time (r(2) = 0.17). Satisfaction scores did not correlate with whether the actual RTAT met expectations (r(2) = 0.06). Referring physician satisfaction is likely multifactorial. Although RTAT has been reported as a priority, shortening turnaround time alone may not directly improve clinician satisfaction. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.
Choosing the right diagnostic imaging modality in musculoskeletal diagnosis.
Aagesen, Andrea L; Melek, Maged
2013-12-01
Radiological studies can confirm or rule out competing diagnoses for musculoskeletal injuries and pain. Obtaining a detailed history and physical examination is pivotal for localizing the pain generator and choosing the most appropriate imaging studies, based on the suspected injured tissue. Judicious use of imaging is important to avoid unnecessary radiation exposure, minimize cost, and avoid therapy targeting asymptomatic imaging abnormalities. This article compares and contrasts the diagnostic imaging commonly used for detecting musculoskeletal injuries. Copyright © 2013 Elsevier Inc. All rights reserved.
Nielsen, Tommy Kjærgaard; Østraat, Øyvind; Graumann, Ole; Pedersen, Bodil Ginnerup; Andersen, Gratien; Høyer, Søren; Borre, Michael
2017-08-01
The present study investigates how computed tomography perfusion scans and magnetic resonance imaging correlates with the histopathological alterations in renal tissue after cryoablation. A total of 15 pigs were subjected to laparoscopic-assisted cryoablation on both kidneys. After intervention, each animal was randomized to a postoperative follow-up period of 1, 2, or 4 weeks, after which computed tomography perfusion and magnetic resonance imaging scans were performed. Immediately after imaging, open bilateral nephrectomy was performed allowing for histopathological examination of the cryolesions. On computed tomography perfusion and magnetic resonance imaging examinations, rim enhancement was observed in the transition zone of the cryolesion 1week after laparoscopic-assisted cryoablation. This rim enhancement was found to subside after 2 and 4 weeks of follow-up, which was consistent with the microscopic examinations revealing of fibrotic scar tissue formation in the peripheral zone of the cryolesion. On T2 magnetic resonance imaging sequences, a thin hypointense rim surrounded the cryolesion, separating it from the adjacent renal parenchyma. Microscopic examinations revealed hemorrhage and later hemosiderin located in the peripheral zone. No nodular or diffuse contrast enhancement was found in the central zone of the cryolesions at any follow-up stage on neither computed tomography perfusion nor magnetic resonance imaging. On microscopic examinations, the central zone was found to consist of coagulative necrosis 1 week after laparoscopic-assisted cryoablation, which was partially replaced by fibrotic scar tissue 4 weeks following laparoscopic-assisted cryoablation. Both computed tomography perfusion and magnetic resonance imaging found the renal collecting system to be involved at all 3 stages of follow-up, but on microscopic examination, the urothelium was found to be intact in all cases. In conclusion, cryoablation effectively destroyed renal parenchyma, leaving the urothelium intact. Both computed tomography perfusion and magnetic resonance imaging reflect the microscopic findings but with some differences, especially regarding the peripheral zone. Magnetic resonance imaging seems an attractive modality for early postoperative follow-up.
Hickethier, Tilman; Mammadov, Kamal; Baeßler, Bettina; Lichtenstein, Thorsten; Hinkelbein, Jochen; Smith, Lucy; Plum, Patrick Sven; Chon, Seung-Hun; Maintz, David; Chang, De-Hua
2018-01-01
The study was conducted to compare examination time and artifact vulnerability of whole-body computed tomographies (wbCTs) for trauma patients using conventional or optimized patient positioning. Examination time was measured in 100 patients scanned with conventional protocol (Group A: arms positioned alongside the body for head and neck imaging and over the head for trunk imaging) and 100 patients scanned with optimized protocol (Group B: arms flexed on a chest pillow without repositioning). Additionally, influence of two different scanning protocols on image quality in the most relevant body regions was assessed by two blinded readers. Total wbCT duration was about 35% or 3:46 min shorter in B than in A. Artifacts in aorta (27 vs 6%), liver (40 vs 8%) and spleen (27 vs 5%) occurred significantly more often in B than in A. No incident of non-diagnostic image quality was reported, and no significant differences for lungs and spine were found. An optimized wbCT positioning protocol for trauma patients allows a significant reduction of examination time while still maintaining diagnostic image quality.
Sliding window adaptive histogram equalization of intraoral radiographs: effect on image quality.
Sund, T; Møystad, A
2006-05-01
To investigate whether contrast enhancement by non-interactive, sliding window adaptive histogram equalization (SWAHE) can enhance the image quality of intraoral radiographs in the dental clinic. Three dentists read 22 periapical and 12 bitewing storage phosphor (SP) radiographs. For the periapical readings they graded the quality of the examination with regard to visually locating the root apex. For the bitewing readings they registered all occurrences of approximal caries on a confidence scale. Each reading was first done on an unprocessed radiograph ("single-view"), and then re-done with the image processed with SWAHE displayed beside the unprocessed version ("twin-view"). The processing parameters for SWAHE were the same for all the images. For the periapical examinations, twin-view was judged to raise the image quality for 52% of those cases where the single-view quality was below the maximum. For the bitewing radiographs, there was a change of caries classification (both positive and negative) with twin-view in 19% of the cases, but with only a 3% net increase in the total number of caries registrations. For both examinations interobserver variance was unaffected. Non-interactive SWAHE applied to dental SP radiographs produces a supplemental contrast enhanced image which in twin-view reading improves the image quality of periapical examinations. SWAHE also affects caries diagnosis of bitewing images, and further study using a gold standard is warranted.
Beauty and thinness messages in children's media: a content analysis.
Herbozo, Sylvia; Tantleff-Dunn, Stacey; Gokee-Larose, Jessica; Thompson, J Kevin
2004-01-01
Research suggests that young children have body image concerns, such as a desire for thinness and an avoidance of obesity. Surprisingly, few studies have investigated how children's body preferences and stereotypes are influenced by media aimed at children. In order to gain a better understanding of the content of such media, a content analysis was used to examine body image-related messages in popular children's videos and books. Results indicated that messages emphasizing the importance of physical appearance and portraying body stereotypes are present in many children's videos but relatively few books. Of the videos examined, the ones that exhibited the most body image-related messages were Cinderella and The Little Mermaid. Indian in the Cupboard and ET were the videos with the least number of body image-related messages. Of the books studied, the one with the highest number of body image-related messages was Rapunzel. Ginger and The Stinky Cheese Man were the only books studied that did not exhibit body image-related messages. Implications of an association of beauty and thinness in children's media are explored.
Detection of Potentially Severe Retinopathy of Prematurity by Remote Image Grading.
Quinn, Graham E; Ying, Gui-Shuang; Pan, Wei; Baumritter, Agnieshka; Daniel, Ebenezer
2017-09-01
Telemedicine in retinopathy of prematurity (ROP) has the potential for delivering timely care to premature infants at risk for serious ROP. To describe the characteristics of eyes at risk for ROP to provide insights into what types of ROP are most easily detected early by image grading. Secondary analysis of eyes with referral-warranted (RW) ROP (stage 3 ROP, zone I ROP, plus disease) on diagnostic examination from the Telemedicine Approaches to Evaluating Acute-Phase Retinopathy of Prematurity (e-ROP) study was conducted from May 1, 2011, to October 31, 2013, in 1257 premature infants with birth weights less than 1251 g in 13 neonatal units in North America. Data analysis was performed between February 1, 2016, and June 5, 2017. Serial imaging sessions with concurrent diagnostic examinations for ROP. Time of detecting RW-ROP on image evaluation compared with clinical examination. In the e-ROP study, 246 infants (492 eyes) were included in the analysis; 138 (56.1%) were male. A total of 447 eyes had RW-ROP on diagnostic examination. Image grading in 123 infants (mean [SD] gestational age, 24.8 [1.4] weeks) detected RW-ROP earlier than diagnostic examination (early) in 191 (42.7%) eyes by about 15 days and detected RW-ROP in 123 infants (mean [SD] gestational age, 24.6 [1.5] weeks) at the same time (same) in 200 (44.7%) eyes. Most of the early eyes (153 [80.1%]) interpreted as being RW-ROP positive on imaging evaluation agreed with examination findings when the examination subsequently documented RW-ROP. At the sessions in which RW-ROP was first found by examination, stage 3 or more in 123 infants (mean [SD] gestational age, 24.8 [1.4] weeks) ROP was noted earlier on image evaluation in 151 of 191 early eyes (79.1%) and in 172 of 200 of same eyes (86.0%) (P = .08); the presence of zone I ROP was detected in 57 of 191 (29.8%) early eyes vs 64 of 200 (32.0%) same eyes (P = .90); and plus disease was noted in 30 of 191 (15.7%) early eyes and 45 of 200 (22.5%) same eyes (P = .08). In both early and same eyes, zone I and/or stage 3 ROP determined a significant proportion of RW-ROP; plus disease played a relatively minor role. In most early RW-ROP eyes, the findings were consistent with clinical examination and/or image grading at the next session. Because ROP telemedicine is used more widely, development of standard approaches and protocols is essential.
Jensen, Chad D; Duraccio, Kara M; Barnett, Kimberly A; Stevens, Kimberly S
2016-12-01
Research examining effects of visual food cues on appetite-related brain processes and eating behavior has proliferated. Recently investigators have developed food image databases for use across experimental studies examining appetite and eating behavior. The food-pics image database represents a standardized, freely available image library originally validated in a large sample primarily comprised of adults. The suitability of the images for use with adolescents has not been investigated. The aim of the present study was to evaluate the appropriateness of the food-pics image library for appetite and eating research with adolescents. Three hundred and seven adolescents (ages 12-17) provided ratings of recognizability, palatability, and desire to eat, for images from the food-pics database. Moreover, participants rated the caloric content (high vs. low) and healthiness (healthy vs. unhealthy) of each image. Adolescents rated approximately 75% of the food images as recognizable. Approximately 65% of recognizable images were correctly categorized as high vs. low calorie and 63% were correctly classified as healthy vs. unhealthy in 80% or more of image ratings. These results suggest that a smaller subset of the food-pics image database is appropriate for use with adolescents. With some modifications to included images, the food-pics image database appears to be appropriate for use in experimental appetite and eating-related research conducted with adolescents. Copyright © 2016 Elsevier Ltd. All rights reserved.
Concept Learning through Image Processing.
ERIC Educational Resources Information Center
Cifuentes, Lauren; Yi-Chuan, Jane Hsieh
This study explored computer-based image processing as a study strategy for middle school students' science concept learning. Specifically, the research examined the effects of computer graphics generation on science concept learning and the impact of using computer graphics to show interrelationships among concepts during study time. The 87…
Cirla, A.; Rondena, M.; Bertolini, G.
2016-01-01
The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses. PMID:27540512
Cirla, A; Rondena, M; Bertolini, G
2016-01-01
The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses.
Incidental findings in imaging research: evaluating incidence, benefit, and burden.
Orme, Nicholas M; Fletcher, Joel G; Siddiki, Hassan A; Harmsen, W Scott; O'Byrne, Megan M; Port, John D; Tremaine, William J; Pitot, Henry C; McFarland, Elizabeth G; Robinson, Marguerite E; Koenig, Barbara A; King, Bernard F; Wolf, Susan M
2010-09-27
Little information exists concerning the frequency and medical significance of incidental findings (IFs) in imaging research. Medical records of research participants undergoing a research imaging examination interpreted by a radiologist during January through March 2004 were reviewed, with 3-year clinical follow-up. An expert panel reviewed all IFs generating clinical action to determine medical benefit/burden on the basis of predefined criteria. The frequency of IFs that generated further clinical action was estimated by modality, body part, age, and sex, along with net medical benefit or burden. Of 1426 research imaging examinations, 567 (39.8%) had at least 1 IF (1055 total). Risk of an IF increased significantly by age (odds ratio [OR], 1.5; 95% confidence interval, 1.4-1.7 per decade increase). Abdominopelvic computed tomography generated more IFs than other examinations (OR, 18.9 vs ultrasonography; 9.2% with subsequent clinical action), with computed tomography of the thorax and magnetic resonance imaging of the head next (OR, 11.9 and 5.9; 2.8% and 2.2% with action, respectively). Of the 567 examinations with an IF, 35 (6.2%) generated clinical action, resulting in clear medical benefit in 1.1% (6 of 567) and clear medical burden in 0.5% (3 of 567). Medical benefit/burden was usually unclear (26 of 567 [4.6%]). Frequency of IFs in imaging research examinations varies significantly by imaging modality, body region, and age. Research imaging studies at high risk for generating IFs can be identified. Routine evaluation of research images by radiologists may result in identification of IFs in a high number of cases and subsequent clinical action to address them in a small but significant minority. Such clinical action can result in medical benefit to a small number of patients.
Payne, Gemma; Reedy, Brian; Lennard, Chris; Comber, Bruce; Exline, David; Roux, Claude
2005-05-28
This study investigated the application of chemical imaging to the detection of latent fingerprints using the Condor macroscopic chemical imaging system (ChemImage Corp., Pittsburgh, USA). Methods were developed and optimised for the visualisation of untreated latent fingerprints and fingerprints processed with DFO, ninhydrin, cyanoacrylate, and cyanoacrylate plus rhodamine 6G stain. The results obtained with chemical imaging were compared to the detection achieved using conventional imaging techniques. The Condor significantly improved the detection of many prints, especially those that might be considered poor quality or borderline prints. Prints on newspaper treated with ninhydrin and DFO, and prints on white and yellow paper treated with ninhydrin, benefited the most from chemical imaging detection. In many cases, fingerprints undetectable using conventional imaging techniques could be visualised with chemical imaging. Ridge detail from untreated prints on yellow paper was also detected using the Condor. When prints of high quality were examined, both detection techniques produced quality results. The results of this project demonstrate that chemical imaging offers advantages over conventional visualisation techniques when examining latent fingerprints, especially those that would be considered difficult, such as weak prints or prints on surfaces that produce highly luminescent backgrounds. Standard testing procedures for the detection and enhancement of fingerprints by chemical imaging are presented and discussed.
Body Image Concerns in College-Aged Male Physical Education Students: A Descriptive Inquiry
ERIC Educational Resources Information Center
Olson, Michele S.; Esco, Michael R.; Willifo, Hank
2009-01-01
The purpose of this study was to examine body image concerns in college-aged male physical education majors. Sixty volunteers completed validated body image instruments including two-dimensional figure drawings. In general, the sample reported that they preferred a larger, more muscular physique reflective of male images that currently abound the…
Xu, Jian; Kim, Daniel; Otazo, Ricardo; Srichai, Monvadi B; Lim, Ruth P; Axel, Leon; Mcgorty, Kelly Anne; Niendorf, Thoralf; Sodickson, Daniel K
2013-07-01
To evaluate the feasibility and perform initial comparative evaluations of a 5-minute comprehensive whole-heart magnetic resonance imaging (MRI) protocol with four image acquisition types: perfusion (PERF), function (CINE), coronary artery imaging (CAI), and late gadolinium enhancement (LGE). This study protocol was Health Insurance Portability and Accountability Act (HIPAA)-compliant and Institutional Review Board-approved. A 5-minute comprehensive whole-heart MRI examination protocol (Accelerated) using 6-8-fold-accelerated volumetric parallel imaging was incorporated into and compared with a standard 2D clinical routine protocol (Standard). Following informed consent, 20 patients were imaged with both protocols. Datasets were reviewed for image quality using a 5-point Likert scale (0 = non-diagnostic, 4 = excellent) in blinded fashion by two readers. Good image quality with full whole-heart coverage was achieved using the accelerated protocol, particularly for CAI, although significant degradations in quality, as compared with traditional lengthy examinations, were observed for the other image types. Mean total scan time was significantly lower for the Accelerated as compared to Standard protocols (28.99 ± 4.59 min vs. 1.82 ± 0.05 min, P < 0.05). Overall image quality for the Standard vs. Accelerated protocol was 3.67 ± 0.29 vs. 1.5 ± 0.51 (P < 0.005) for PERF, 3.48 ± 0.64 vs. 2.6 ± 0.68 (P < 0.005) for CINE, 2.35 ± 1.01 vs. 2.48 ± 0.68 (P = 0.75) for CAI, and 3.67 ± 0.42 vs. 2.67 ± 0.84 (P < 0.005) for LGE. Diagnostic image quality for Standard vs. Accelerated protocols was 20/20 (100%) vs. 10/20 (50%) for PERF, 20/20 (100%) vs. 18/20 (90%) for CINE, 18/20 (90%) vs. 18/20 (90%) for CAI, and 20/20 (100%) vs. 18/20 (90%) for LGE. This study demonstrates the technical feasibility and promising image quality of 5-minute comprehensive whole-heart cardiac examinations, with simplified scan prescription and high spatial and temporal resolution enabled by highly parallel imaging technology. The study also highlights technical hurdles that remain to be addressed. Although image quality remained diagnostic for most scan types, the reduced image quality of PERF, CINE, and LGE scans in the Accelerated protocol remain a concern. Copyright © 2012 Wiley Periodicals, Inc.
Application of optical character recognition in thermal image processing
NASA Astrophysics Data System (ADS)
Chan, W. T.; Sim, K. S.; Tso, C. P.
2011-07-01
This paper presents the results of a study on the reliability of the thermal imager compared to other devices that are used in preventive maintenance. Several case studies are used to facilitate the comparisons. When any device is found to perform unsatisfactorily where there is a suspected fault, its short-fall is determined so that the other devices may compensate, if possible. This study discovered that the thermal imager is not suitable or efficient enough for systems that happen to have little contrast in temperature between its parts or small but important parts that have their heat signatures obscured by those from other parts. The thermal imager is also found to be useful for preliminary examinations of certain systems, after which other more economical devices are suitable substitutes for further examinations. The findings of this research will be useful to the design and planning of preventive maintenance routines for industrial benefits.
NASA Technical Reports Server (NTRS)
Meyer, P. J.
1993-01-01
An image data visual browse facility is developed for a UNIX platform using the X Windows 11 system. It allows one to visually examine reduced resolution image data to determine which data are applicable for further research. Links with a relational data base manager then allow one to extract not only the full resolution image data, but any other ancillary data related to the case study. Various techniques are examined for compression of the image data in order to reduce data storage requirements and time necessary to transmit the data on the internet. Data used were from the WetNet project.
Raman chemical imaging of explosive-contaminated fingerprints.
Emmons, E D; Tripathi, A; Guicheteau, J A; Christesen, S D; Fountain, A W
2009-11-01
Raman chemical imaging (RCI) has been used to detect and identify explosives in contaminated fingerprints. Bright-field imaging is used to identify regions of interest within a fingerprint, which can then be examined to determine their chemical composition using RCI and fluorescence imaging. Results are presented where explosives in contaminated fingerprints are identified and their spatial distributions are obtained. Identification of explosives is obtained using Pearson's cosine cross-correlation technique using the characteristic region (500-1850 cm(-1)) of the spectrum. This study shows the ability to identify explosives nondestructively so that the fingerprint remains intact for further biometric analysis. Prospects for forensic examination of contaminated fingerprints are discussed.
NASA Astrophysics Data System (ADS)
Lane, Ciara; Stynes, Martin; O'Donoghue, John
2016-10-01
A questionnaire survey was carried out as part of a PhD research study to investigate the image of mathematics held by post-primary students in Ireland. The study focused on students in fifth year of post-primary education studying ordinary level mathematics for the Irish Leaving Certificate examination - the final examination for students in second-level or post-primary education. At the time this study was conducted, ordinary level mathematics students constituted approximately 72% of Leaving Certificate students. Students were aged between 15 and 18 years. A definition for 'image of mathematics' was adapted from Lim and Wilson, with image of mathematics hypothesized as comprising attitudes, beliefs, self-concept, motivation, emotions and past experiences of mathematics. A questionnaire was composed incorporating 84 fixed-response items chosen from eight pre-established scales by Aiken, Fennema and Sherman, Gourgey and Schoenfeld. This paper focuses on the findings from the questionnaire survey. Students' images of mathematics are compared with regard to gender, type of post-primary school attended and prior mathematical achievement.
Silva, Paolo S; Cavallerano, Jerry D; Sun, Jennifer K; Noble, Jason; Aiello, Lloyd M; Aiello, Lloyd Paul
2012-09-01
To compare nonmydriatic stereoscopic Optomap ultrawide field images with dilated stereoscopic Early Treatment Diabetic Retinopathy Study 7-standard field 35-mm color 30-degree fundus photographs (ETDRS photography) and clinical examination for determining diabetic retinopathy (DR) and diabetic macular edema (DME) severity. Single-site, prospective, comparative, instrument validation study. One hundred three diabetic patients (206 eyes) representing the full spectrum of DR severity underwent nonmydriatic ultrawide field 100-degree and 200-degree imaging, dilated ETDRS photography, and dilated fundus examination by a retina specialist. Two independent readers graded images to determine DR and DME severity. A third masked retina specialist adjudicated discrepancies. Based on ETDRS photography (n = 200), the results were as follows: no DR (n = 25 eyes [12.5%]), mild nonproliferative DR (NPDR; 47 [23.5%]), moderate NPDR (61 [30.5%]), severe NPDR (11 [5.5%]), very severe NPDR (3 [1.5%]), and proliferative DR (52 [2.5%]). One (0.5%) eye was ungradable and 6 eyes did not complete ETDRS photography. No DME was found in 114 eyes (57.0%), DME was found in 28 eyes (14.0%), and clinically significant DME was found in 47 eyes (23.5%), and 11 (5.5%) eyes were ungradable. Exact DR severity agreement between ultrawide field 100-degree imaging and ETDRS photography occurred in 84%, with agreement within 1 level in 91% (K(W) = 0.85; K = 0.79). Nonmydriatic ultrawide field images exactly matched clinical examination results for DR in 70% and were within 1 level in 93% (K(W) = 0.71; K = 0.61). Nonmydriatic ultrawide field imaging acquisition time was less than half that of dilated ETDRS photography (P < .0001). Nonmydriatic ultrawide field images compare favorably with dilated ETDRS photography and dilated fundus examination in determining DR and DME severity; however, they are acquired more rapidly. If confirmed in broader diabetic populations, nonmydriatic ultrawide field imaging may prove to be beneficial in DR evaluation in research and clinical settings. Copyright © 2012 Elsevier Inc. All rights reserved.
Nakashima, Ryoichi; Iwai, Ritsuko; Ueda, Sayako; Kumada, Takatsune
2015-01-01
When observers perceive several objects in a space, at the same time, they should effectively perceive their own position as a viewpoint. However, little is known about observers’ percepts of their own spatial location based on the visual scene information viewed from them. Previous studies indicate that two distinct visual spatial processes exist in the locomotion situation: the egocentric position perception and egocentric direction perception. Those studies examined such perceptions in information rich visual environments where much dynamic and static visual information was available. This study examined these two perceptions in information of impoverished environments, including only static lane edge information (i.e., limited information). We investigated the visual factors associated with static lane edge information that may affect these perceptions. Especially, we examined the effects of the two factors on egocentric direction and position perceptions. One is the “uprightness factor” that “far” visual information is seen at upper location than “near” visual information. The other is the “central vision factor” that observers usually look at “far” visual information using central vision (i.e., foveal vision) whereas ‘near’ visual information using peripheral vision. Experiment 1 examined the effect of the “uprightness factor” using normal and inverted road images. Experiment 2 examined the effect of the “central vision factor” using normal and transposed road images where the upper half of the normal image was presented under the lower half. Experiment 3 aimed to replicate the results of Experiments 1 and 2. Results showed that egocentric direction perception is interfered with image inversion or image transposition, whereas egocentric position perception is robust against these image transformations. That is, both “uprightness” and “central vision” factors are important for egocentric direction perception, but not for egocentric position perception. Therefore, the two visual spatial perceptions about observers’ own viewpoints are fundamentally dissociable. PMID:26648895
How do we watch images? A case of change detection and quality estimation
NASA Astrophysics Data System (ADS)
Radun, Jenni; Leisti, Tuomas; Virtanen, Toni; Nyman, Göte
2012-01-01
The most common tasks in subjective image estimation are change detection (a detection task) and image quality estimation (a preference task). We examined how the task influences the gaze behavior when comparing detection and preference tasks. The eye movements of 16 naïve observers were recorded with 8 observers in both tasks. The setting was a flicker paradigm, where the observers see a non-manipulated image, a manipulated version of the image and again the non-manipulated image and estimate the difference they perceived in them. The material was photographic material with different image distortions and contents. To examine the spatial distribution of fixations, we defined the regions of interest using a memory task and calculated information entropy to estimate how concentrated the fixations were on the image plane. The quality task was faster and needed fewer fixations and the first eight fixations were more concentrated on certain image areas than the change detection task. The bottom-up influences of the image also caused more variation to the gaze behavior in the quality estimation task than in the change detection task The results show that the quality estimation is faster and the regions of interest are emphasized more on certain images compared with the change detection task that is a scan task where the whole image is always thoroughly examined. In conclusion, in subjective image estimation studies it is important to think about the task.
Forsberg, Daniel; Gupta, Amit; Mills, Christopher; MacAdam, Brett; Rosipko, Beverly; Bangert, Barbara A; Coffey, Michael D; Kosmas, Christos; Sunshine, Jeffrey L
2017-03-01
The purpose of this study was to investigate how the use of multi-modal rigid image registration integrated within a standard picture archiving and communication system affects the efficiency of a radiologist while performing routine interpretations of cases including prior examinations. Six radiologists were recruited to read a set of cases (either 16 neuroradiology or 14 musculoskeletal cases) during two crossover reading sessions. Each radiologist read each case twice, one time with synchronized navigation, which enables spatial synchronization across examinations from different study dates, and one time without. Efficiency was evaluated based upon time to read a case and amount of scrolling while browsing a case using Wilcoxon signed rank test. Significant improvements in efficiency were found considering either all radiologists simultaneously, the two sections separately and the majority of individual radiologists for time to read and for amount of scrolling. The relative improvement for each individual radiologist ranged from 4 to 32% for time to read and from 14 to 38% for amount of scrolling. Image registration providing synchronized navigation across examinations from different study dates provides a tool that enables radiologists to work more efficiently while reading cases with one or more prior examinations.
de Lange, T; Møystad, A; Torgersen, G R
2018-02-13
The aims of the study were to investigate benefits and challenges in implementing a digital examination and study the clinical relevance of the digital examination in relation to clinical training and practice. The study was based on semi-structured focus-group interviews from two distinct student populations (2016 and 2017) in a bachelor programme in dental hygiene. In addition, conversational data from a plenary discussion from the whole second student population (2017) were collected and analysed. The data were approached on basis of content analysis. A benefit experienced in the digital examination was the ease in typing and editing answers on the computer. This suggests an increased effectiveness in computer-based compared to analogue examinations. An additional advantage was the experienced relevance of the examination related to the clinic. This finding refers not only to the digital presentations of images, but also to the entire setting in the clinic and dental practice. The limitations reported by the students were non-optimal viewing conditions for presenting radiographic images and difficulties in obtaining an overview of the assignments compared to paper-based examinations due to the linear digital examination format. The last finding on lacking overview revealed an influence on student performances which should be taken seriously in designing digital examinations. In conclusion, the digital layout increases efficiency and clinical relevance of examinations to a certain extent. Obstacles were found in limitations related to image presentation and lack of overview of the examination. The latter challenge raises questions related to developing suitable assessment software. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Jackson, Kathryn L; Janssen, Imke; Appelhans, Bradley M; Kazlauskaite, Rasa; Karavolos, Kelly; Dugan, Sheila A; Avery, Elizabeth A; Shipp-Johnson, Karla J; Powell, Lynda H; Kravitz, Howard M
2014-06-01
With aging, women's bodies undergo changes that can affect body image perception, yet little is known about body image in midlife. The purpose of this study was to examine associations between body image and depressive symptoms in Caucasian and African-American midlife women from the Study of Women's Health Across the Nation (SWAN) Chicago site. Body image was measured using the Stunkard Adult Female Figure Rating Scale, and a clinically significant level of depressive symptoms was defined as Center for Epidemiologic Studies Depression Scale (CES-D) score of ≥16 (N=405; N=63 (15.6%) with clinically significant levels of depressive symptoms). Differences between perceived actual, perceived ideal, and actual body size and responses to questions concerning weight satisfaction and attractiveness were examined using logistic regression for associations with a CES-D score of ≥16. Women with body image dissatisfaction (odds ratio (OR)=1.91; p=0.04) or who perceived themselves as "unattractive" (OR=7.74; p<0.01) had higher odds of CES-D of ≥16. We found no significant difference by race. Our results were not confounded by BMI. These results suggest that midlife women with poor body image may be more likely to have clinically significant levels of depressive symptoms. Larger prospective studies are needed to better understand this association.
Jackson, Kathryn L.; Janssen, Imke; Appelhans, Bradley M.; Kazlauskaite, Rasa; Karavolos, Kelly; Dugan, Sheila A.; Avery, Elizabeth A.; Shipp-Johnson, Karla J.; Powell, Lynda H.; Kravitz, Howard M.
2014-01-01
With aging, women's bodies undergo changes that can affect body image perception, yet little is known about body image in midlife. The purpose of this study was to examine associations between body image and depressive symptoms in Caucasian and African–American midlife women from the Study of Women's Health Across the Nation (SWAN) Chicago site. Body image was measured using the Stunkard Adult Female Figure Rating Scale, and a clinically significant level of depressive symptoms was defined as Center for Epidemiologic Studies Depression Scale (CES-D) score of ≥16 (N=405; N=63 (15.6 %) with clinically significant levels of depressive symptoms). Differences between perceived actual, perceived ideal, and actual body size and responses to questions concerning weight satisfaction and attractiveness were examined using logistic regression for associations with a CES-D score of ≥16. Women with body image dissatisfaction (odds ratio (OR)=1.91; p=0.04) or who perceived themselves as “unattractive” (OR=7.74; p<0.01) had higher odds of CES-D of ≥16. We found no significant difference by race. Our results were not confounded by BMI. These results suggest that midlife women with poor body image may be more likely to have clinically significant levels of depressive symptoms. Larger prospective studies are needed to better understand this association. PMID:24623160
ERIC Educational Resources Information Center
Weaver, Angela D.; Byers, E. Sandra
2006-01-01
Problems related to negative body image are very common among young women. In this study, we examined the relationship between women's body image and their sexual functioning over and above the effects of physical exercise and body mass index (BMI) in a sample of 214 university women. Low situational body image dysphoria and low body…
ERIC Educational Resources Information Center
Vorstenbosch, Marc A. T. M.; Klaassen, Tim P. F. M.; Kooloos, Jan G. M.; Bolhuis, Sanneke M.; Laan, Roland F. J. M.
2013-01-01
Anatomists often use images in assessments and examinations. This study aims to investigate the influence of different types of images on item difficulty and item discrimination in written assessments. A total of 210 of 460 students volunteered for an extra assessment in a gross anatomy course. This assessment contained 39 test items grouped in…
The Ability of Grade 5 Students To Use Radarsat Satellite Images.
ERIC Educational Resources Information Center
Kirman, Joseph M.; Busby, Stephanie
2000-01-01
A study examined the ability of 32 grade-5 students in Alberta (Canada) to interpret Radarsat satellite radar images. The students were able to interpret most elements of the images, but working directly with the CD-ROM proved too difficult for them. The Radarsat images have limited value as a geographic resource at the grade-5 level. (TD)
Ophthalmic applications of confocal microscopy: diagnostics, refractive surgery, and eye banking
NASA Astrophysics Data System (ADS)
Masters, Barry R.
1990-11-01
Confocal microscopy of ocular tissue provides two advantages over traditional imaging techniques: increased range and transverse resolution and increased contrast. The semitransparent cornea and ocular lens in the living eye can be optically sectioned and observed by reflected light confocal microscopy. Within the cornea we observed various cell components nerve fibers nerve cell bodies and fibrous networks. The confocal microscopic images from the in-situ ocular lens show the lens capsule the lens epithelium and the individual lens fibrils. All of the reflected light confocal microscopic images have high contrast and high resolution. Some of the applications of confocal imaging in ophthalmology include: diagnostics of the cornea and the ocular lens examination prior to and after refractive surgery examination of intraocular lenses (IOL) and examination of eye bank material. Other ophthalmic uses of confocal imaging include: studies of wound healing therapeutics and the effects of contact lenses on the cornea. The proposed features of a clinical confocal microscope are reviewed. 2.
An MRI system for imaging neonates in the NICU: initial feasibility study.
Tkach, Jean A; Hillman, Noah H; Jobe, Alan H; Loew, Wolfgang; Pratt, Ron G; Daniels, Barret R; Kallapur, Suhas G; Kline-Fath, Beth M; Merhar, Stephanie L; Giaquinto, Randy O; Winter, Patrick M; Li, Yu; Ikegami, Machiko; Whitsett, Jeffrey A; Dumoulin, Charles L
2012-11-01
Transporting premature infants from a neonatal intensive care unit (NICU) to a radiology department for MRI has medical risks and logistical challenges. To develop a small 1.5-T MRI system for neonatal imaging that can be easily installed in the NICU and to evaluate its performance using a sheep model of human prematurity. A 1.5-T MRI system designed for orthopedic use was adapted for neonatal imaging. The system was used for MRI examinations of the brain, chest and abdomen in 12 premature lambs during the first hours of life. Spin-echo, fast spin-echo and gradient-echo MR images were evaluated by two pediatric radiologists. All animals remained physiologically stable throughout the imaging sessions. Animals were imaged at two or three time points. Seven brain MRI examinations were performed in seven different animals, 23 chest examinations in 12 animals and 19 abdominal examinations in 11 animals. At each anatomical location, high-quality images demonstrating good spatial resolution, signal-to-noise ratio and tissue contrast were routinely obtained within 30 min using standard clinical protocols. Our preliminary experience demonstrates the feasibility and potential of the neonatal MRI system to provide state-of-the-art MRI capabilities within the NICU. Advantages include overall reduced cost and site demands, lower acoustic noise, improved ease of access and reduced medical risk to the neonate.
Terada, Masaki; Matsushita, Hiroki; Oosugi, Masanori; Inoue, Kazuyasu; Yaegashi, Taku; Anma, Takeshi
2009-03-20
The advantage of the higher signal-to-noise ratio (SNR) of 3-Tesla magnetic resonance imaging (3-Tesla) has the possibility of contributing to the improvement of high spatial resolution without causing image deterioration. In this study, we compared SNR and the apparent diffusion coefficient (ADC) value with 3-Tesla as the condition in the diffusion-weighted image (DWI) parameter of the 1.5-Tesla magnetic resonance imaging (1.5-Tesla) and we examined the high spatial resolution images in the imaging method [respiratory-triggering (RT) method and breath free (BF) method] and artifact (motion and zebra) in the upper abdominal region of DWI at 3-Tesla. We have optimized scan parameters based on phantom and in vivo study. As a result, 3-Tesla was able to obtain about 1.5 times SNR in comparison with the 1.5-Tesla, ADC value had few differences. Moreover, the RT method was effective in correcting the influence of respiratory movement in comparison with the BF method, and image improvement by the effective acquisition of SNR and reduction of the artifact were provided. Thus, DWI of upper abdominal region was a useful sequence for the high spatial resolution in 3-Tesla.
Images of Africa: A Case Study of Pre-Service Candidates' Perceptions of Teaching Africa
ERIC Educational Resources Information Center
Kim, Hannah
2017-01-01
As much as the history and study of Africa have been incorporated into social studies curricula, Africa is still a region that is prone to misperceptions and misconceptions. Social studies teachers could provide students with an alternative image, but what if they only perpetuate misperceptions of Africa? This case study examines preservice…
ERIC Educational Resources Information Center
DeLeel, Marissa L.; Hughes, Tammy L.; Miller, Jeffrey A.; Hipwell, Alison; Theodore, Lea A.
2009-01-01
Eating disorder research has predominantly focused on White adolescent females. More recent research suggests that eating disorders occur in various racial and age groups. The current study examines prevalence and stability of body image dissatisfaction and eating disturbance in 9- and 10-year-old girls and whether there is variability by racial…
Brichtová, Eva; Šenkyřík, J
2017-05-01
A low radiation burden is essential during diagnostic procedures in pediatric patients due to their high tissue sensitivity. Using MR examination instead of the routinely used CT reduces the radiation exposure and the risk of adverse stochastic effects. Our retrospective study evaluated the possibility of using ultrafast single-shot (SSh) sequences and turbo spin echo (TSE) sequences in rapid MR brain imaging in pediatric patients with hydrocephalus and a programmable ventriculoperitoneal drainage system. SSh sequences seem to be suitable for examining pediatric patients due to the speed of using this technique, but significant susceptibility artifacts due to the programmable drainage valve degrade the image quality. Therefore, a rapid MR examination protocol based on TSE sequences, less sensitive to artifacts due to ferromagnetic components, has been developed. Of 61 pediatric patients who were examined using MR and the SSh sequence protocol, a group of 15 patients with hydrocephalus and a programmable drainage system also underwent TSE sequence MR imaging. The susceptibility artifact volume in both rapid MR protocols was evaluated using a semiautomatic volumetry system. A statistically significant decrease in the susceptibility artifact volume has been demonstrated in TSE sequence imaging in comparison with SSh sequences. Using TSE sequences reduced the influence of artifacts from the programmable valve, and the image quality in all cases was rated as excellent. In all patients, rapid MR examinations were performed without any need for intravenous sedation or general anesthesia. Our study results strongly suggest the superiority of the TSE sequence MR protocol compared to the SSh sequence protocol in pediatric patients with a programmable ventriculoperitoneal drainage system due to a significant reduction of susceptibility artifact volume. Both rapid sequence MR protocols provide quick and satisfactory brain imaging with no ionizing radiation and a reduced need for intravenous or general anesthesia.
Gross, M Melissa; Wright, Mary C; Anderson, Olivia S
2017-09-01
Research on the benefits of visual learning has relied primarily on lecture-based pedagogy, but the potential benefits of combining active learning strategies with visual and verbal materials on learning anatomy has not yet been explored. In this study, the differential effects of text-based and image-based active learning exercises on examination performance were investigated in a functional anatomy course. Each class session was punctuated with an average of 12 text-based and image-based active learning exercises. Participation data from 231 students were compared with their examination performance on 262 questions associated with the in-class exercises. Students also rated the helpfulness and difficulty of the in-class exercises on a survey. Participation in the active learning exercises was positively correlated with examination performance (r = 0.63, P < 0.001). When controlling for other key demographics (gender, underrepresented minority status) and prior grade point average, participation in the image-based exercises was significantly correlated with performance on examination questions associated with image-based exercises (P < 0.001) and text-based exercises (P < 0.01), while participation in text-based exercises was not. Additionally, students reported that the active learning exercises were helpful for seeing images of key ideas (94%) and clarifying key course concepts (80%), and that the image-based exercises were significantly less demanding, less hard and required less effort than text-based exercises (P < 0.05). The findings confirm the positive effect of using images and active learning strategies on student learning, and suggest that integrating them may be especially beneficial for learning anatomy. Anat Sci Educ 10: 444-455. © 2017 American Association of Anatomists. © 2017 American Association of Anatomists.
Variability of manual ciliary muscle segmentation in optical coherence tomography images.
Chang, Yu-Cherng; Liu, Keke; Cabot, Florence; Yoo, Sonia H; Ruggeri, Marco; Ho, Arthur; Parel, Jean-Marie; Manns, Fabrice
2018-02-01
Optical coherence tomography (OCT) offers new options for imaging the ciliary muscle allowing direct in vivo visualization. However, variation in image quality along the length of the muscle prevents accurate delineation and quantification of the muscle. Quantitative analyses of the muscle are accompanied by variability in segmentation between examiners and between sessions for the same examiner. In processes such as accommodation where changes in muscle thickness may be tens of microns- the equivalent of a small number of image pixels, differences in segmentation can influence the magnitude and potentially the direction of thickness change. A detailed analysis of variability in ciliary muscle thickness measurements was performed to serve as a benchmark for the extent of this variability in studies on the ciliary muscle. Variation between sessions and examiners were found to be insignificant but the magnitude of variation should be considered when interpreting ciliary muscle results.
2013-01-01
Background In an ongoing study of racial/ethnic disparities in breast cancer stage at diagnosis, we consented patients to allow us to review their mammogram images, in order to examine the potential role of mammogram image quality on this disparity. Methods In a population-based study of urban breast cancer patients, a single breast imaging specialist (EC) performed a blinded review of the index mammogram that prompted diagnostic follow-up, as well as recent prior mammograms performed approximately one or two years prior to the index mammogram. Seven indicators of image quality were assessed on a five-point Likert scale, where 4 and 5 represented good and excellent quality. These included 3 technologist-associated image quality (TAIQ) indicators (positioning, compression, sharpness), and 4 machine associated image quality (MAIQ) indicators (contrast, exposure, noise and artifacts). Results are based on 494 images examined for 268 patients, including 225 prior images. Results Whereas MAIQ was generally high, TAIQ was more variable. In multivariable models of sociodemographic predictors of TAIQ, less income was associated with lower TAIQ (p < 0.05). Among prior mammograms, lower TAIQ was subsequently associated with later stage at diagnosis, even after adjusting for multiple patient and practice factors (OR = 0.80, 95% CI: 0.65, 0.99). Conclusions Considerable gains could be made in terms of increasing image quality through better positioning, compression and sharpness, gains that could impact subsequent stage at diagnosis. PMID:23621946
Imaging and examination strategies of normal male and female sex development and anatomy.
Wünsch, Lutz; Schober, Justine M
2007-09-01
Over recent years a variety of new details on the developmental biology of sexual differentiation has been discovered. Moreover, important advances have been made in imaging and examination strategies for urogenital organs, and these have added new knowledge to our understanding of the 'normal' anatomy of the sexes. Both aspects contribute to the comprehension of phenotypic sex development, but they are not commonly presented in the same context. This will be attempted in this chapter, which aims to link discoveries in developmental biology to anatomical details shown by modern examination techniques. A review of the literature concerning the link between sexual development and imaging of urogenital organs was performed. Genes, proteins and pathways related to sexual differentiation were related to some organotypic features revealed by clinical examination techniques. Early 'organotypic' patterns can be identified in prostatic, urethral and genital development and followed into postnatal life. New imaging and endoscopy techniques allow for detailed descriptive anatomical studies, hopefully resulting in a broader understanding of sex development and a better genotype-phenotype correlation in defined disorders. Clinical description relying on imaging techniques should be related to knowledge of the genetic and endocrine factors influencing sex development in a specific and stepwise manner.
Walter, Uwe; Niendorf, Thoralf; Graessl, Andreas; Rieger, Jan; Krüger, Paul-Christian; Langner, Sönke; Guthoff, Rudolf F; Stachs, Oliver
2014-05-01
A combination of magnetic resonance images with real-time high-resolution ultrasound known as fusion imaging may improve ophthalmologic examination. This study was undertaken to evaluate the feasibility of orbital high-field magnetic resonance and real-time colour Doppler ultrasound image fusion and navigation. This case study, performed between April and June 2013, included one healthy man (age, 47 years) and two patients (one woman, 57 years; one man, 67 years) with choroidal melanomas. All cases underwent 7.0-T magnetic resonance imaging using a custom-made ocular imaging surface coil. The Digital Imaging and Communications in Medicine volume data set was then loaded into the ultrasound system for manual registration of the live ultrasound image and fusion imaging examination. Data registration, matching and then volume navigation were feasible in all cases. Fusion imaging provided real-time imaging capabilities and high tissue contrast of choroidal tumour and optic nerve. It also allowed adding a real-time colour Doppler signal on magnetic resonance images for assessment of vasculature of tumour and retrobulbar structures. The combination of orbital high-field magnetic resonance and colour Doppler ultrasound image fusion and navigation is feasible. Multimodal fusion imaging promises to foster assessment and monitoring of choroidal melanoma and optic nerve disorders. • Orbital magnetic resonance and colour Doppler ultrasound real-time fusion imaging is feasible • Fusion imaging combines the spatial and temporal resolution advantages of each modality • Magnetic resonance and ultrasound fusion imaging improves assessment of choroidal melanoma vascularisation.
Tucker, F. Lee
2012-01-01
Modern breast imaging, including magnetic resonance imaging, provides an increasingly clear depiction of breast cancer extent, often with suboptimal pathologic confirmation. Pathologic findings guide management decisions, and small increments in reported tumor characteristics may rationalize significant changes in therapy and staging. Pathologic techniques to grossly examine resected breast tissue have changed little during this era of improved breast imaging and still rely primarily on the techniques of gross inspection and specimen palpation. Only limited imaging information is typically conveyed to pathologists, typically in the form of wire-localization images from breast-conserving procedures. Conventional techniques of specimen dissection and section submission destroy the three-dimensional integrity of the breast anatomy and tumor distribution. These traditional methods of breast specimen examination impose unnecessary limitations on correlation with imaging studies, measurement of cancer extent, multifocality, and margin distance. Improvements in pathologic diagnosis, reporting, and correlation of breast cancer characteristics can be achieved by integrating breast imagers into the specimen examination process and the use of large-format sections which preserve local anatomy. This paper describes the successful creation of a large-format pathology program to routinely serve all patients in a busy interdisciplinary breast center associated with a community-based nonprofit health system in the United States. PMID:23316372
Imaging techniques in digital forensic investigation: a study using neural networks
NASA Astrophysics Data System (ADS)
Williams, Godfried
2006-09-01
Imaging techniques have been applied to a number of applications, such as translation and classification problems in medicine and defence. This paper examines the application of imaging techniques in digital forensics investigation using neural networks. A review of applications of digital image processing is presented, whiles a Pedagogical analysis of computer forensics is also highlighted. A data set describing selected images in different forms are used in the simulation and experimentation.
Yang, Wen Jie; Zhang, Huan; Xiao, Hua; Li, Jian Ying; Liu, Yan; Pan, Zi Lai; Chen, Ke Min
2012-01-01
The evaluation of coronary stents by computed tomography (CT) remains difficult. We assessed the imaging performance of a high-definition CT scanner (HDCT) by comparing with a conventional 64-row standard-definition CT (SDCT). One hundred thirty-eight consecutive stented patients underwent coronary CT angiography, among whom 66 patients were examined by HDCT, and 72 patients by SDCT (LightSpeed VCT XT; GE Healthcare, Waukesha, Wis). The image quality score, the inner stent diameter (ISD), and the radiation dose were analyzed. All data were statistically tested by SPSS 13.0 software (SPSS Inc, Chicago, Ill). In 72 patients examined using SDCT, 135 stents were detected; in 66 patients examined using HDCT, 119 stents were detected. The image quality score on HDCT was significantly better than that on SDCT (1.4 [SD, 0.7] vs 1.9 [SD, 0.8]). The ISD on HDCT was significantly higher than that on SDCT (1.8 [SD, 0.5] vs 1.6 [SD, 0.4]). There was no significant difference of either image quality score or ISD between the HDCT and SDCT groups in stents with 2.5-mm diameter. Images on HDCT showed significantly better image quality score and larger ISD than images on SDCT in 2.75-, 3-, and 3.5-mm stents. For patients examined by retrospective electrocardiogram-gated technique, the radiation dose on HDCT was significantly lower than that on SDCT (11.3 [SD, 2.9] vs 15.1 [SD, 3.8] mSv). High-definition CT scanner offered improved image quality and measurement accuracy for imaging coronary stents compared with conventional SDCT, providing higher spatial resolution and lower dose for evaluating coronary stents with 2.75- to 3.5-mm diameter.
Acquiring skill at medical image inspection: learning localized in early visual processes
NASA Astrophysics Data System (ADS)
Sowden, Paul T.; Davies, Ian R. L.; Roling, Penny; Watt, Simon J.
1997-04-01
Acquisition of the skill of medical image inspection could be due to changes in visual search processes, 'low-level' sensory learning, and higher level 'conceptual learning.' Here, we report two studies that investigate the extent to which learning in medical image inspection involves low- level learning. Early in the visual processing pathway cells are selective for direction of luminance contrast. We exploit this in the present studies by using transfer across direction of contrast as a 'marker' to indicate the level of processing at which learning occurs. In both studies twelve observers trained for four days at detecting features in x- ray images (experiment one equals discs in the Nijmegen phantom, experiment two equals micro-calcification clusters in digitized mammograms). Half the observers examined negative luminance contrast versions of the images and the remainder examined positive contrast versions. On the fifth day, observers swapped to inspect their respective opposite contrast images. In both experiments leaning occurred across sessions. In experiment one, learning did not transfer across direction of luminance contrast, while in experiment two there was only partial transfer. These findings are consistent with the contention that some of the leaning was localized early in the visual processing pathway. The implications of these results for current medical image inspection training schedules are discussed.
A Longitudinal Study of Body Image and Strategies to Lose Weight and Increase Muscles among Children
ERIC Educational Resources Information Center
McCabe, M. P.; Ricciardelli, L. A.
2005-01-01
A longitudinal study was used to examine age differences in the role of body mass index (BMI) and sociocultural pressures in predicting changes in body image and strategies to both lose weight and increase muscles among 443 children aged between 8 and 12 years (207 boys, 236 girls) over a 16-month period. The strongest predictors of body image and…
NASA Astrophysics Data System (ADS)
Park, Sang Cheol; Zheng, Bin; Wang, Xiao-Hui; Gur, David
2008-03-01
Digital breast tomosynthesis (DBT) has emerged as a promising imaging modality for screening mammography. However, visually detecting micro-calcification clusters depicted on DBT images is a difficult task. Computer-aided detection (CAD) schemes for detecting micro-calcification clusters depicted on mammograms can achieve high performance and the use of CAD results can assist radiologists in detecting subtle micro-calcification clusters. In this study, we compared the performance of an available 2D based CAD scheme with one that includes a new grouping and scoring method when applied to both projection and reconstructed DBT images. We selected a dataset involving 96 DBT examinations acquired on 45 women. Each DBT image set included 11 low dose projection images and a varying number of reconstructed image slices ranging from 18 to 87. In this dataset 20 true-positive micro-calcification clusters were visually detected on the projection images and 40 were visually detected on the reconstructed images, respectively. We first applied the CAD scheme that was previously developed in our laboratory to the DBT dataset. We then tested a new grouping method that defines an independent cluster by grouping the same cluster detected on different projection or reconstructed images. We then compared four scoring methods to assess the CAD performance. The maximum sensitivity level observed for the different grouping and scoring methods were 70% and 88% for the projection and reconstructed images with a maximum false-positive rate of 4.0 and 15.9 per examination, respectively. This preliminary study demonstrates that (1) among the maximum, the minimum or the average CAD generated scores, using the maximum score of the grouped cluster regions achieved the highest performance level, (2) the histogram based scoring method is reasonably effective in reducing false-positive detections on the projection images but the overall CAD sensitivity is lower due to lower signal-to-noise ratio, and (3) CAD achieved higher sensitivity and higher false-positive rate (per examination) on the reconstructed images. We concluded that without changing the detection threshold or performing pre-filtering to possibly increase detection sensitivity, current CAD schemes developed and optimized for 2D mammograms perform relatively poorly and need to be re-optimized using DBT datasets and new grouping and scoring methods need to be incorporated into the schemes if these are to be used on the DBT examinations.
[Evaluation of the resolving power of different angles in MPR images of 16DAS-MDCT].
Kimura, Mikio; Usui, Junshi; Nozawa, Takeo
2007-03-20
In this study, we evaluated the resolving power of three-dimensional (3D) multiplanar reformation (MPR) images with various angles by using 16 data acquisition system multi detector row computed tomography (16DAS-MDCT) . We reconstructed the MPR images using data with a 0.75 mm slice thickness of the axial image in this examination. To evaluate resolving power, we used an original new phantom (RC phantom) that can be positioned at any slice angle in MPR images. We measured the modulation transfer function (MTF) by using the methods of measuring pre-sampling MTF, and used Fourier transform of image data of the square wave chart. The scan condition and image reconstruction condition that were adopted in this study correspond to the condition that we use for three-dimensional computed tomographic angiography (3D-CTA) examination of the head in our hospital. The MTF of MPR images showed minimum values at slice angles in parallel with the axial slice, and showed maximum values at the sagittal slice and coronal slice angles that are parallel to the Z-axis. With an oblique MPR image, MTF did not change with angle changes in the oblique sagittal slice plane, but in the oblique coronal slice plane, MTF increased as the tilt angle increased from the axial plane to the Z plane. As a result, we could evaluate the resolving power of a head 3D image by measuring the MTF of the axial image and sagittal image or the coronal image.
Investigating Adolescent Stress and Body Image
ERIC Educational Resources Information Center
Murray, Kristen M.; Byrne, Don G.; Rieger, Elizabeth
2011-01-01
Adolescent stress is clearly implicated in the development of mental health problems. However, its role in dysfunctional body image, which rises markedly in adolescence, has not been investigated. The present study examined the link between stress and body image, as well as self-esteem and depressive symptoms, in 533 high school students in grades…
(Pea)nuts and Bolts of Visual Narrative: Structure and Meaning in Sequential Image Comprehension
ERIC Educational Resources Information Center
Cohn, Neil; Paczynski, Martin; Jackendoff, Ray; Holcomb, Phillip J.; Kuperberg, Gina R.
2012-01-01
Just as syntax differentiates coherent sentences from scrambled word strings, the comprehension of sequential images must also use a cognitive system to distinguish coherent narrative sequences from random strings of images. We conducted experiments analogous to two classic studies of language processing to examine the contributions of narrative…
Impact of Internet Images: Impression-Formation Effects of University Web Site Images
ERIC Educational Resources Information Center
Ramasubramanian, Srividya; Gyure, James F.; Mursi, Nasreen M.
2002-01-01
Institutions of higher education are increasingly becoming dependent on Web-based marketing to reach out to their target audiences. The current empirical study examines the types of impressions formed by prospective students based on exposure to different university Web site images. A between-subjects experiment was conducted using four identical…
[Evaluation of upper cervical spine injury (C1-C2) with computed tomography].
Siemianowicz, Anna; Baron, Jan; Wawrzynek, Wojciech; Koczy, Bogdan; Kasprowska, Sabina
2006-01-01
Cervical spine injuries are common and essential diagnostic problem. Diagnostic imaging is necessary for proper and effective treatment. Helical computed tomography (CT) and plain radiography are the basic diagnostic methods in cervical spine injuries. The purpose of this work was the comparison of CT examination of the upper cervical spine (CI-C2) with patients' clinical state. Twenty four patients (17 men and 7 women) were introduced into the study. The most common cause of cervical spine injuries were car accidents (48.5%). CT examination was performed in all patients. Six patients (25%) had multilevel injury, localized at C1-C2 level and in the lower part of cervical spine. The main pathology diagnosed by CT in the studied group was rotatory subluxation (66.6%). Eight patients (33.3%), with rotatory subluxation did not present any abnormalities in neurological examination performed immediately after the admission to the hospital. C1 and/or C2 fractures were diagnosed in 11 patients (45.8%), in some cases (in 3 patients - 12.5%) they were accompanied by rotatory subluxations. CT examination is the basic technique of diagnostic imaging in a case of cervical spine injuries. It enables quick, accurate and precise evaluation of bone structures and surrounding soft tissues. CT also enables multiplanar imaging and 3-dimentional imaging.
Repeatability and Reproducibility of Decisions by Latent Fingerprint Examiners
Ulery, Bradford T.; Hicklin, R. Austin; Buscaglia, JoAnn; Roberts, Maria Antonia
2012-01-01
The interpretation of forensic fingerprint evidence relies on the expertise of latent print examiners. We tested latent print examiners on the extent to which they reached consistent decisions. This study assessed intra-examiner repeatability by retesting 72 examiners on comparisons of latent and exemplar fingerprints, after an interval of approximately seven months; each examiner was reassigned 25 image pairs for comparison, out of total pool of 744 image pairs. We compare these repeatability results with reproducibility (inter-examiner) results derived from our previous study. Examiners repeated 89.1% of their individualization decisions, and 90.1% of their exclusion decisions; most of the changed decisions resulted in inconclusive decisions. Repeatability of comparison decisions (individualization, exclusion, inconclusive) was 90.0% for mated pairs, and 85.9% for nonmated pairs. Repeatability and reproducibility were notably lower for comparisons assessed by the examiners as “difficult” than for “easy” or “moderate” comparisons, indicating that examiners' assessments of difficulty may be useful for quality assurance. No false positive errors were repeated (n = 4); 30% of false negative errors were repeated. One percent of latent value decisions were completely reversed (no value even for exclusion vs. of value for individualization). Most of the inter- and intra-examiner variability concerned whether the examiners considered the information available to be sufficient to reach a conclusion; this variability was concentrated on specific image pairs such that repeatability and reproducibility were very high on some comparisons and very low on others. Much of the variability appears to be due to making categorical decisions in borderline cases. PMID:22427888
Cornfeld, Daniel; Israel, Gary; Detroy, Ezra; Bokhari, Jamal; Mojibian, Hamid
2011-03-01
The purpose of the study was to quantify the radiation dose reduction achieved when imaging the aorta using Adaptive Statistical Iterative Reconstruction (ASIR) and to determine if this has an effect on image quality. We retrospectively reviewed 31 CT angiography examinations of the thoracic and abdominal aorta performed with ASIR and 32 consecutive similar examinations performed without ASIR. Volume CT dose index (CTDI(vol)), dose-length product (DLP), aortic enhancement at multiple levels, aorta-to-muscle contrast-to-noise ratio at multiple levels, and subjective image quality were compared between the two groups. The mean CTDI(vol) and DLP were significantly lower for the studies performed with ASIR versus studies without ASIR (15.6 vs 21.5 mGy, with an average difference of 5.8 mGy [95% CI 2.3-9.4 mGy] and 818 vs 1075 mGy × cm with an average difference of -257 mGy × cm [54-460 mGy × cm], respectively). Aortic enhancement, aortic signal-to-noise ratio, and aortic to muscle contrast-to-noise ratio were not different between the two groups. Subjectively, one reviewer preferred the non-ASIR images and one found the images equivalent. Both reviewers believed the images were of diagnostic quality. A 29% decrease in CTDI(vol) and a 20% decrease in DLP were obtained in scans with ASIR compared with scans without ASIR, without a quantitative loss of image quality.
Gill, Thomas J; Safran, Marc; Mandelbaum, Bert; Huber, Bryan; Gambardella, Ralph; Xerogeanes, John
2018-05-24
The purpose of this study was to compare the efficacy, accuracy, and safety of in-office diagnostic arthroscopy with magnetic resonance imaging (MRI) and surgical diagnostic arthroscopy. A prospective, blinded, multicenter, clinical trial was performed on 110 patients, ages 18 to 75 years, who presented with knee pain. The study period was April 2012 to April 2013. Each patient underwent a physical examination, an MRI, in-office diagnostic imaging, and a diagnostic arthroscopic examination in the operating room. The attending physician completed clinical report forms comparing the in-office arthroscopic examination and surgical diagnostic arthroscopy findings on each patient. Two blinded experts, unaffiliated with the clinical care of the study's subjects, reviewed the in-office arthroscopic images and MRI images using the surgical diagnostic arthroscopy images as the "control" group comparison. Patients were consecutive, and no patients were excluded from the study. In this study, the accuracy, sensitivity, and specificity of in-office arthroscopy was equivalent to surgical diagnostic arthroscopy and more accurate than MRI. When comparing in-office arthroscopy with surgical diagnostic arthroscopy, all kappa statistics were between 0.766 and 0.902. For MRI compared with surgical diagnostic arthroscopy, kappa values ranged from a low of 0.130 (considered "slight" agreement) to a high of 0.535 (considered "moderate" agreement). The comparison of MRI to in-office arthroscopy showed very similar results as the comparison of MRI with surgical diagnostic arthroscopy, ranging from a low kappa of 0.112 (slight agreement) to a high of 0.546 (moderate agreement). There were no patient-related or device-related complications related to the use of in-office arthroscopy. Needle-based diagnostic imaging that can be used in the office setting is statistically equivalent to surgical diagnostic arthroscopy with regard to the diagnosis of intra-articular, nonligamentous knee joint pathology. In-office diagnostic imaging can provide a more detailed and accurate diagnostic assessment of intra-articular knee pathology than MRI. Based on the study results, in-office diagnostic imaging provides a safe, accurate, real-time, minimally invasive diagnostic modality to evaluate intra-articular pathology without the need for surgical diagnostic arthroscopy or high-cost imaging. Level II, comparative prospective trial. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Aftermath of Ankle Inversion Injuries: Spectrum of MR Imaging Findings.
Meehan, Timothy M; Martinez-Salazar, Edgar Leonardo; Torriani, Martin
2017-02-01
Acute and chronic ankle inversion injuries are a common source of pain and a diagnostic challenge. Several studies have shown a variety of injury patterns after inversion injury both in acute and chronic settings. Although traditional assessment with clinical examination and radiographs is generally accepted for inversion injuries, MR imaging is a useful tool to detect occult injuries and in patients with chronic symptoms. This article examines a range of MR imaging findings that may be present in patients with lateral ankle pain following an acute or chronic inversion injury. Copyright © 2016 Elsevier Inc. All rights reserved.
2014-01-01
Background Ultrasonography is an important diagnostic tool in the investigation of abdominal disease in the horse. Several factors may affect the ability to image different structures within the abdomen. The aim of the study was to describe the repeatability of identification of abdominal structures in normal horses using a detailed ultrasonographic examination technique and using a focused, limited preparation technique. Methods A detailed abdominal ultrasound examination was performed in five normal horses, repeated on five occasions (total of 25 examinations). The abdomen was divided into ten different imaging sites, and structures identified in each site were recorded. Five imaging sites were then selected for a single focused ultrasound examination in 20 normal horses. Limited patient preparation was performed. Structures were recorded as ‘identified’ if ultrasonographic features could be distinguished. The location of organs and their frequency of identification were recorded. Data from both phases were analysed to determine repeatability of identification of structures in each examination (irrespective of imaging site), and for each imaging site. Results Caecum, colon, spleen, liver and right kidney were repeatably identified using the detailed technique, and had defined locations. Large colon and right kidney were identified in 100% of examinations with both techniques. Liver, spleen, caecum, duodenum and other small intestine were identified more frequently with the detailed examination. Small intestine was most frequently identified in the ventral abdomen, its identification varied markedly within and between horses, and required repeated examinations in some horses. Left kidney could not be identified in every horse using either technique. Sacculated colon was identified in all ventral sites, and was infrequently identified in dorsal sites. Conclusions Caecum, sacculated large intestine, spleen, liver and right kidney were consistently identified with both techniques. There were some normal variations which should be considered when interpreting ultrasonographic findings in clinical cases: left kidney was not always identified, sacculated colon was occasionally identified in dorsal flank sites. Multiple imaging sites and repeated examinations may be required to identify small intestine. A focused examination identified most key structures, but has some limitations compared to a detailed examination. PMID:25238559
Morita, Yoshinori; Kutsumi, Hiromu; Yoshinaka, Hayato; Matsuoka, Yuichiro; Kuroda, Kagayaki; Gotanda, Masakazu; Sekino, Naomi; Kumamoto, Etsuko; Yoshida, Masaru; Inokuchi, Hideto; Azuma, Takeshi
2009-01-01
The purpose of this study was to visualize the gastric wall layers and to depict the vascular architecture in vitro by using resected porcine stomachs studied with high-spatial resolution magnetic resonance (MR) imaging. Normal dissected porcine stomach samples (n = 4) were examined with a 3 Tesla MR system using a newly developed surface coil. MR images were obtained by the surface coil as receiver and a head coil as transmitter. High-spatial-resolution spin-echo MR images were obtained with a field of view of 8 x 8 cm, a matrix of 256 x 128 and slice thicknesses of 3 and 5 mm. T1 and T2-weighted MR images clearly depicted the normal porcine gastric walls as consisting of four distinct layers. In addition, vascular architectures in proper muscle layers were also visualized, which were confirmed by histological examinations to correspond to blood vessels. High-spatial-resolution MR imaging using a surface coil placed closely to the gastric wall enabled the differentiation of porcine gastric wall layers and the depiction of the blood vessels in proper muscle layer in this experimental study.
Brown, Danice L; White-Johnson, Rhonda L; Griffin-Fennell, Felicia D
2013-01-01
The historical image of the Black Jezebel - a hypersexual, seductive and manipulative slave woman - has been one of the most pervasive and evolving images influencing the sexual socialization and perceptions of African American women today. This preliminary study examined generational differences in the endorsement of modern depictions of the Jezebel, as well as the relationship between racial-ethnic esteem and endorsement of this sexualised image. A total of 249 African American women completed an online, self-report questionnaire assessing study variables. Results suggested that younger women (aged 18-34) may exhibit higher endorsement of the modern Jezebel depictions. Additionally, aspects of racial-ethnic esteem may be linked to lower endorsement of modern Jezebel depictions among younger and older (55 years and older) African American women. Implications for future research and clinical practice are discussed.
Examination of a sociocultural model of excessive exercise among male and female adolescents.
White, James; Halliwell, Emma
2010-06-01
There is substantial evidence that sociocultural pressures and body image disturbances can lead to disordered eating, yet few studies have examined their impact on excessive exercise. The study adapted a sociocultural model for disordered eating to predict excessive exercise using data from boys and girls in early adolescence (N=421). Perceived sociocultural pressures to lose weight and build muscle, body image disturbance and appearance investment were associated with a compulsive need to exercise. Adolescents' investment in appearance and body image disturbance fully mediated the relationship between sociocultural pressures and a compulsive need for exercise. There was no support for the meditational model in predicting adolescents' frequency or duration of exercise. Results support the sociocultural model as an explanatory model for excessive exercise, but suggest appearance investment and body image disturbance are important mediators of sociocultural pressures. 2010 Elsevier Ltd. All rights reserved.
Marcus, Inna; Tung, Irene T; Dosunmu, Eniolami O; Thiamthat, Warakorn; Freedman, Sharon F
2013-12-01
To compare anterior segment findings identified in young children using digital photographic images from the Lytro light field camera to those observed clinically. This was a prospective study of children <9 years of age with an anterior segment abnormality. Clinically observed anterior segment examination findings for each child were recorded and several digital images of the anterior segment of each eye captured with the Lytro camera. The images were later reviewed by a masked examiner. Sensitivity of abnormal examination findings on Lytro imaging was calculated and compared to the clinical examination as the gold standard. A total of 157 eyes of 80 children (mean age, 4.4 years; range, 0.1-8.9) were included. Clinical examination revealed 206 anterior segment abnormalities altogether: lids/lashes (n = 21 eyes), conjunctiva/sclera (n = 28 eyes), cornea (n = 71 eyes), anterior chamber (n = 14 eyes), iris (n = 43 eyes), and lens (n = 29 eyes). Review of Lytro photographs of eyes with clinically diagnosed anterior segment abnormality correctly identified 133 of 206 (65%) of all abnormalities. Additionally, 185 abnormalities in 50 children were documented at examination under anesthesia. The Lytro camera was able to document most abnormal anterior segment findings in un-sedated young children. Its unique ability to allow focus change after image capture is a significant improvement on prior technology. Copyright © 2013 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.
Imaging Practice Patterns: Referral Network Analysis of a Single State of Origination.
Grayson, James; Basciano, Peter; Rawson, James V; Klein, Kandace
2015-12-01
The aim of this study was to examine the referral pattern of imaging studies requested in a single state compared with the potential location of interpretation. Analysis of Medicare patients in a DocGraph data set was performed to identify sequential different physician services claims for the same patient for which the second claim was for services provided by a radiologist. In the 2011 Medicare population, radiology referrals from physicians practicing in Georgia resulted in 76.5% of radiology interpretations by radiologists inside the state of Georgia. The states bordering Georgia accounted for 11.6% of interpretations in the Georgia market. The remaining interpretations were distributed throughout the remainder of the country. A significant proportion of routine imaging interpretation occurs outside the state in which an examination is performed. Additional studies are needed to identify complex drivers of imaging referral patterns, such as patient geographic location and demographics, radiologist workforce distribution, contractual obligations, and social relationships. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.
The value of digital imaging in diabetic retinopathy.
Sharp, P F; Olson, J; Strachan, F; Hipwell, J; Ludbrook, A; O'Donnell, M; Wallace, S; Goatman, K; Grant, A; Waugh, N; McHardy, K; Forrester, J V
2003-01-01
To assess the performance of digital imaging, compared with other modalities, in screening for and monitoring the development of diabetic retinopathy. All imaging was acquired at a hospital assessment clinic. Subsequently, study optometrists examined the patients in their own premises. A subset of patients also had fluorescein angiography performed every 6 months. Research clinic at the hospital eye clinic and optometrists' own premises. Study comprised 103 patients who had type 1 diabetes mellitus, 481 had type 2 diabetes mellitus and two had secondary diabetes mellitus; 157 (26.8%) had some form of retinopathy ('any') and 58 (9.9%) had referable retinopathy. A repeat assessment was carried out of all patients 1 year after their initial assessment. Patients who had more severe forms of retinopathy were monitored more frequently for evidence of progression. Detection of retinopathy, progression of retinopathy and determination of when treatment is required. Manual grading of 35-mm colour slides produced the highest sensitivity and specificity figures, with optometrist examination recording most false negatives. Manual and automated analysis of digital images had intermediate sensitivity. Both manual grading of 35-mm colour slides and digital images gave sensitivities of over 90% with few false positives. Digital imaging produced 50% fewer ungradable images than colour slides. This part of the study was limited as patients with the more severe levels of retinopathy opted for treatment. There was an increase in the number of microaneurysms in those patients who developed from mild to moderate. There was no difference between the turnover rate of either new or regressed microaneurysms for patients with mild or with sight-threatening retinopathy. It was not possible in this study to ascertain whether digital imaging systems determine when treatment is warranted. In the context of a national screening programme for referable retinopathy, digital imaging is an effective method. In addition, technical failure rates are lower with digital imaging than conventional photography. Digital imaging is also a more sensitive technique than slit-lamp examination by optometrists. Automated grading can improve efficiency by correctly identifying just under half the population as having no retinopathy. Recommendations for future research include: investigating whether the nasal field is required for grading; a large screening programme is required to ascertain if automated grading can safely perform as a first-level grader; if colour improves the performance of grading digital images; investigating methods to ensure effective uptake in a diabetic retinopathy screening programme.
Korn, Liat; Gonen, Ester; Shaked, Yael; Golan, Moria
2013-01-01
This study examines health perceptions, self and body image, physical exercise and nutrition among undergraduate students. A structured, self-reported questionnaire was administered to more than 1500 students at a large academic institute in Israel. The study population was heterogenic in both gender and fields of academic study. High correlations between health perceptions, appropriate nutrition, and positive self and body image were found. The relationships between these variables differed between the subpopulation in the sample and the different genders. Engagement in physical exercise contributed to positive body image and positive health perceptions more than engagement in healthy nutrition. Nutrition students reported higher frequencies of positive health perceptions, positive self and body image and higher engagement in physical exercise in comparison to all other students in the sample. This study suggests, as have many before, that successful health promotion policy should reflect a collectivist rather than an individualist ethos by providing health prerequisites through a public policy of health-promotion, where the academic settings support a healthy lifestyle policy, by increasing availability of a healthy, nutritious and varied menu in the cafeterias, and offering students various activities that enhance healthy eating and exercise. IMPLICATIONS AND CONTRIBUTION: This study examined health perceptions, self-image, physical exercise and nutrition among undergraduate students and found high correlations between these topics. Nutrition students reported higher frequencies of positive health perceptions, and positive self and body image and engaged more in physical exercise when compared with all other students in the sample.
Impact of ultrasound video transfer on the practice of ultrasound
NASA Astrophysics Data System (ADS)
Duerinckx, Andre J.; Hayrapetian, Alek S.; Grant, Edward G.; Valentino, Daniel J.; Rahbar, Darius; Kiszonas, Mike; Franco, Ricky; Melany, Michelle; Narin, Sherelle L.; Ragavendra, Nagesh
1996-05-01
Sonography can be highly dependent on real-time imaging and as such is highly physician intensive. Such situations arise mostly during complicated ultrasound radiology studies or echocardiology examinations. Under those circumstances it would be of benefit to transmit real-time images beyond the immediate area of the ultrasound laboratory when a physician is not on location. We undertook this study to determine if both static and dynamic image transfer to remote locations might be accomplished using an ultrafast ATM network and PACS. Image management of the local image files was performed by a commercial PACS from AGFA corporation. The local network was Ethernet based, and the global network was based on Asynchronous Transfer Mode (ATM, rates up to 100 Mbits/sec). Real-time image transfer involved two teaching hospitals, one of which had 2 separate ultrasound facilities. Radiologists consulted with technologists via telephone while the examinations were being performed. The applications of ATM network providing real time video for ultrasound imaging in a clinical environment and its potential impact on health delivery and clinical teaching. This technology increased technologist and physician productivity due to the elimination of commute time for physicians and waiting time for technologists and patients. Physician confidence in diagnosis increased compared to reviewing static images alone. This system provided instant access for radiologists to real-time scans from remote sites. Image quality and frame rate were equivalent to the original. The system increased productivity by allowing physicians to monitor studies at multiple sites simultaneously.
ERIC Educational Resources Information Center
Vorperian, Houri K.; Wang, Shubing; Schimek, E. Michael; Durtschi, Reid B.; Kent, Ray D.; Gentry, Lindell R.; Chung, Moo K.
2011-01-01
Purpose: The anatomic origin for prepubertal vowel acoustic differences between male and female subjects remains unknown. The purpose of this study is to examine developmental sex differences in vocal tract (VT) length and its oral and pharyngeal portions. Method: Nine VT variables were measured from 605 imaging studies (magnetic resonance imaging…
Imaging of all three coronary arteries by transthoracic echocardiography. an illustrated guide
Krzanowski, Marek; Bodzoń, Wojciech; Dimitrow, Paweł Petkow
2003-01-01
Background Improvements in ultrasound technology has enabled direct, transthoracic visualization of long portions of coronary arteries : the left anterior descending (LAD), circumflex (Cx) and right coronary artery (RCA). Transthoracic measurements of coronary flow velocity were proved to be highly reproducible and correlated with invasive measurements. While clinical applications of transthoracic echocardiography (TTE) of principal coronary arteries are still very limited they will likely grow. The echocardiographers may therefore be interested to know the ultrasonic views, technique of examination and be aware where to look for coronary arteries and how to optimize the images. Methods A step-by-step approach to direct, transthoracic visualization of the LAD, Cx and RCA is presented. The technique of examination is discussed, correlations with basic coronary angiography views and heart anatomy are shown and extensively illustrated with photographs and movie-pictures. Hints concerning optimization of ultrasound images are presented and artifacts of imaging are discussed. Conclusions Direct, transthoracic examination of the LAD, Cx and RCA in adults is possible and may become a useful adjunct to other methods of coronary artery examination but studies are needed to establish its role. PMID:14622441
Miéville, Frédéric A; Gudinchet, François; Rizzo, Elena; Ou, Phalla; Brunelle, Francis; Bochud, François O; Verdun, Francis R
2011-09-01
Radiation dose exposure is of particular concern in children due to the possible harmful effects of ionizing radiation. The adaptive statistical iterative reconstruction (ASIR) method is a promising new technique that reduces image noise and produces better overall image quality compared with routine-dose contrast-enhanced methods. To assess the benefits of ASIR on the diagnostic image quality in paediatric cardiac CT examinations. Four paediatric radiologists based at two major hospitals evaluated ten low-dose paediatric cardiac examinations (80 kVp, CTDI(vol) 4.8-7.9 mGy, DLP 37.1-178.9 mGy·cm). The average age of the cohort studied was 2.6 years (range 1 day to 7 years). Acquisitions were performed on a 64-MDCT scanner. All images were reconstructed at various ASIR percentages (0-100%). For each examination, radiologists scored 19 anatomical structures using the relative visual grading analysis method. To estimate the potential for dose reduction, acquisitions were also performed on a Catphan phantom and a paediatric phantom. The best image quality for all clinical images was obtained with 20% and 40% ASIR (p < 0.001) whereas with ASIR above 50%, image quality significantly decreased (p < 0.001). With 100% ASIR, a strong noise-free appearance of the structures reduced image conspicuity. A potential for dose reduction of about 36% is predicted for a 2- to 3-year-old child when using 40% ASIR rather than the standard filtered back-projection method. Reconstruction including 20% to 40% ASIR slightly improved the conspicuity of various paediatric cardiac structures in newborns and children with respect to conventional reconstruction (filtered back-projection) alone.
Duarte, Cristiana; Pinto-Gouveia, José
2017-12-01
This study examined the phenomenology of shame experiences from childhood and adolescence in a sample of women with Binge Eating Disorder. Moreover, a path analysis was investigated testing whether the association between shame-related memories which are traumatic and central to identity, and binge eating symptoms' severity, is mediated by current external shame, body image shame and body image cognitive fusion. Participants in this study were 114 patients, who were assessed through the Eating Disorder Examination and the Shame Experiences Interview, and through self-report measures of external shame, body image shame, body image cognitive fusion and binge eating symptoms. Shame experiences where physical appearance was negatively commented or criticized by others were the most frequently recalled. A path analysis showed a good fit between the hypothesised mediational model and the data. The traumatic and centrality qualities of shame-related memories predicted current external shame, especially body image shame. Current shame feelings were associated with body image cognitive fusion, which, in turn, predicted levels of binge eating symptomatology. Findings support the relevance of addressing early shame-related memories and negative affective and self-evaluative experiences, namely related to body image, in the understanding and management of binge eating. Copyright © 2017 Elsevier B.V. All rights reserved.
Grouping of optic flow stimuli during binocular rivalry is driven by monocular information.
Holten, Vivian; Stuit, Sjoerd M; Verstraten, Frans A J; van der Smagt, Maarten J
2016-10-01
During binocular rivalry, perception alternates between two dissimilar images, presented dichoptically. Although binocular rivalry is thought to result from competition at a local level, neighboring image parts with similar features tend to be perceived together for longer durations than image parts with dissimilar features. This simultaneous dominance of two image parts is called grouping during rivalry. Previous studies have shown that this grouping depends on a shared eye-of-origin to a much larger extent than on image content, irrespective of the complexity of a static image. In the current study, we examine whether grouping of dynamic optic flow patterns is also primarily driven by monocular (eye-of-origin) information. In addition, we examine whether image parameters, such as optic flow direction, and partial versus full visibility of the optic flow pattern, affect grouping durations during rivalry. The results show that grouping of optic flow is, as is known for static images, primarily affected by its eye-of-origin. Furthermore, global motion can affect grouping durations, but only under specific conditions. Namely, only when the two full optic flow patterns were presented locally. These results suggest that grouping during rivalry is primarily driven by monocular information even for motion stimuli thought to rely on higher-level motion areas. Copyright © 2016 Elsevier Ltd. All rights reserved.
The Association Between Body Image and Smoking Cessation Among Individuals Living with HIV/AIDS
Fingeret, Michelle Cororve; Vidrine, Damon J.; Arduino, Roberto C.; Gritz, Ellen R.
2007-01-01
Lower smoking cessation rates are associated with body image concerns in the general population. This relationship is particularly important to study in individuals living with HIV/AIDS due to alarmingly high smoking rates and considerable bodily changes experienced with HIV disease progression and treatment. The association between body image and smoking cessation rates was examined among individuals living with HIV/AIDS participating in a smoking cessation intervention. Body image concerns were significantly associated with depression, anxiety, stress, and social support, all variables known to affect cessation rates. However, reduced quit rates were found among individuals reporting elevated and low levels of body image concerns at the end of treatment. These findings suggest a unique relationship between smoking and body image among individuals living with HIV/AIDS. Further research is needed to examine these effects and whether moderate levels of body image concerns in this population reflect realistic body perceptions associated with positive mental health. PMID:18089265
Self-affirmation theory and cigarette smoking warning images.
DiBello, Angelo M; Neighbors, Clayton; Ammar, Joe
2015-02-01
The present study examined self-affirmation theory, cigarette smoking, and health-related images depicting adverse effects of smoking. Previous research examining self-affirmation and negative health-related images has shown that individuals who engage in a self-affirmation activity are more receptive to messages when compared to those who do not affirm. We were interested in examining the extent to which self-affirmation would reduce defensive responding to negative health images related to cigarette smoking. Participants included 203 daily smokers who were undergraduate students at a large southern university. Participants completed a battery of questionnaires and were then randomly assigned to one of four conditions (non-smoking image control, smoking image control, low affirmation, and high affirmation). Analyses evaluated the effectiveness of affirmation condition as it related to defensive responding. Results indicated that both affirmation conditions were effective in reducing defensive responding for those at greatest risk (heavier smokers) and those more resistant to health benefits associated with quitting. Findings are discussed in terms of potential public health implications as well as the role defensive responding plays in the evaluation and processing of negative health messages. Copyright © 2014 Elsevier Ltd. All rights reserved.
Lateral hip pain: findings from magnetic resonance imaging and clinical examination.
Woodley, Stephanie J; Nicholson, Helen D; Livingstone, Vicki; Doyle, Terence C; Meikle, Grant R; Macintosh, Janet E; Mercer, Susan R
2008-06-01
Prospective cross-sectional study. To examine the radiological and physical therapy diagnoses of lateral hip pain (LHP), and determine the validity of selected clinical variables for predicting gluteal tendon pathology. LHP is frequently encountered by clinicians. Further investigation is required to establish the specific pathologies implicated in the cause of LHP, and which clinical tests are useful in the assessment of this problem. Forty patients with unilateral LHP underwent a physical therapy examination followed by magnetic resonance imaging (MRI) studies. Three radiologists analyzed the images of both hips for signs of pathology. Interobserver reliability of the image analyses, the agreement between the physical therapy and radiological diagnoses, and the validity of the clinical tests were examined. Gluteus medius tendon pathology, bursitis, osteoarthritis and gluteal muscle atrophy (predominantly affecting gluteus minimus) were all implicated in the imaging report of LHP. While prevalent in symptomatic hips, abnormalities were also identified in asymptomatic hips, particularly relating to the diagnosis of bursitis. The strength of agreement between radiologists was variable and little agreement existed between the physical therapy and radiological diagnoses of pathology. Nine of the 26 clinical variables examined in relation to gluteal tendon pathology had likelihood ratios above 2.0 or below 0.5, but the associated 95% confidence intervals were large. The diagnosis of LHP is challenging and our results highlight some problems associated with the use of MRI as a diagnostic reference standard. This factor, together with the imprecise point estimates of the likelihood ratios, means that no firm conclusions can be made regarding the diagnostic utility of the clinical tests used in the assessment of gluteal tendon pathology.
Deleel, Marissa L; Hughes, Tammy L; Miller, Jeffrey A; Hipwell, Alison; Theodore, Lea A
2009-09-01
Eating disorder research has predominantly focused on White adolescent females. More recent research suggests that eating disorders occur in various racial and age groups. The current study examines prevalence and stability of body image dissatisfaction and eating disturbance in 9- and 10-year-old girls and whether there is variability by racial group or socioeconomic status (SES). Five hundred eighty-one girls completed the Children's Eating Attitude Test (ChEAT) and the Body Image Measure (BIM). Results showed that 11% of the sample scored in the Anorexic range at age 9 and about 7% at age 10. When examining body image, 35% of the sample at age 9 and 38% at age 10 selected Ideal Figures that were smaller than their Real Figures on the BIM. There was a significant difference between the racial groups in their reports of eating disturbance, but not body image dissatisfaction. Specifically, the Minority group had higher eating disturbance scores on average at ages 9 and 10 when compared to the White group. SES did not account for eating disturbance or body image dissatisfaction. These results challenge the maxim that eating disturbance and body image dissatisfaction occur primarily in White females from middle and upper SES populations.
ERIC Educational Resources Information Center
Buckley, Jennifer Lynne
2011-01-01
The purpose of this study was to help higher education practitioners and researchers better understand the role that body image plays in first-year traditional-aged college females' development of physical competence and also provide new insights regarding the role that body image plays in the psychosocial development of first-year…
ERIC Educational Resources Information Center
Helminen, Elisa; Punamaki, Raija-Leena
2008-01-01
This study examines the impact of military trauma on contextualized emotional images in children's dreams, and the function of the intensity and valence of the emotional images in protecting mental health from negative trauma impact. Participants were 345 Palestinian children and adolescents (aged 5-16 years) belonging to high trauma (Gaza) and…
Self-Harm Behaviour in Adolescents: Body Image and Self-Esteem
ERIC Educational Resources Information Center
Oktan, Vesile
2017-01-01
This research aimed to reveal the relationship between self-harm behaviour, body image, and self-esteem, and examined whether there was a difference between the body image and self-esteem of the adolescents who exhibited self-harm behaviour and those who did not. The study was conducted with the participation of 263 high school students--143…
University Social Responsibility and Brand Image of Private Universities in Bangkok
ERIC Educational Resources Information Center
Plungpongpan, Jirawan; Tiangsoongnern, Leela; Speece, Mark
2016-01-01
Purpose: The purpose of this paper is to examine the effects of university social responsibility (USR) on the brand image of private universities in Thailand. Brand image is important for entry into the consideration set as prospective students evaluate options for university study. USR activities may be implicit or explicit, i.e., actively…
The Effect of Camera Angle and Image Size on Source Credibility and Interpersonal Attraction.
ERIC Educational Resources Information Center
McCain, Thomas A.; Wakshlag, Jacob J.
The purpose of this study was to examine the effects of two nonverbal visual variables (camera angle and image size) on variables developed in a nonmediated context (source credibility and interpersonal attraction). Camera angle and image size were manipulated in eight video taped television newscasts which were subsequently presented to eight…
ERIC Educational Resources Information Center
Williamson, Vickie M.; Hegarty, Mary; Deslongchamps, Ghislain; Williamson, Kenneth C., III
2013-01-01
This pilot study examined students' use of ball-and-stick images versus electrostatic potential maps when asked questions about electron density, positive charge, proton attack, and hydroxide attack with six different molecules (two alcohols, two carboxylic acids, and two hydroxycarboxylic acids). Students' viewing of these dual images…
ERIC Educational Resources Information Center
Aljomaa, Suliman Saleh
2018-01-01
The study aimed at examining the relationship between body image satisfaction and bulimia nervosa among the students of education faculty at king said university students. The author used the tests of bulimia nervosa and body image test. The researcher verified tests reliability. Students from King Saud University randomly selected (No. 337)…
Cultural Interpretations of the Visual Meaning of Icons and Images Used in North American Web Design
ERIC Educational Resources Information Center
Knight, Eliot; Gunawardena, Charlotte N.; Aydin, Cengiz Hakan
2009-01-01
This study examines cross-cultural interpretations of icons and images drawn from US academic websites. Participants from Morocco, Sri Lanka, Turkey, and the USA responded to an online questionnaire containing 18 icons and images representing online functions and information types common on US academic websites. Participants supplied meanings for…
Shining Lights or Lone Wolves? Creativity and Self Image in Primary School Children.
ERIC Educational Resources Information Center
Hoff, Eva V.; Carlsson, Ingegerd
2002-01-01
This study examined the relationship between self-image and creativity in 69 Swedish 4th graders using three measures of creativity. Results showed no self-image differences between children with high and low creativity. Different creativity measures were significantly related with the exception of one subtest of the Creative Functioning Test,…
Images of Older People in UK Magazine Advertising: Toward a Typology
ERIC Educational Resources Information Center
Williams, Angie; Wadleigh, Paul Mark; Ylanne, Virpi
2010-01-01
The use of images of older people in the British advertising media has been under-researched to date. Further, previous research in any country has tended to examine such images from an "a priori" framework of general impressions and stereotypes of older people. This study addresses these issues with British consumers' (n = 106)…
Radiometric calibration of spacecraft using small lunar images
Kieffer, Hugh H.; Anderson, James M.; Becker, Kris J.
1999-01-01
In this study, the data reduction steps that can be used to extract the lunar irradiance from low resolution images of the Moon are examined and the attendant uncertainties are quantitatively assessed. The response integrated over an image is compared to a lunar irradiance model being developed from terrestrial multi-band photometric observations over the 350-2500 nm range.
ERIC Educational Resources Information Center
Zhang, Xiaofen; Clements, M. A.; Ellerton, Nerida F.
2015-01-01
This study investigated how fifth-grade children's concept images of the unit fractions represented by the symbols 1/2, 1/3/ and 1/4 changed as a result of their participation in an instructional intervention based on multiple embodiments of fraction concepts. The participants' concept images were examined through pre- and post-teaching written…
A comparison of sequential and spiral scanning techniques in brain CT.
Pace, Ivana; Zarb, Francis
2015-01-01
To evaluate and compare image quality and radiation dose of sequential computed tomography (CT) examinations of the brain and spiral CT examinations of the brain imaged on a GE HiSpeed NX/I Dual Slice 2CT scanner. A random sample of 40 patients referred for CT examination of the brain was selected and divided into 2 groups. Half of the patients were scanned using the sequential technique; the other half were scanned using the spiral technique. Radiation dose data—both the computed tomography dose index (CTDI) and the dose length product (DLP)—were recorded on a checklist at the end of each examination. Using the European Guidelines on Quality Criteria for Computed Tomography, 4 radiologists conducted a visual grading analysis and rated the level of visibility of 6 anatomical structures considered necessary to produce images of high quality. The mean CTDI(vol) and DLP values were statistically significantly higher (P <.05) with the sequential scans (CTDI(vol): 22.06 mGy; DLP: 304.60 mGy • cm) than with the spiral scans (CTDI(vol): 14.94 mGy; DLP: 229.10 mGy • cm). The mean image quality rating scores for all criteria of the sequential scanning technique were statistically significantly higher (P <.05) in the visual grading analysis than those of the spiral scanning technique. In this local study, the sequential technique was preferred over the spiral technique for both overall image quality and differentiation between gray and white matter in brain CT scans. Other similar studies counter this finding. The radiation dose seen with the sequential CT scanning technique was significantly higher than that seen with the spiral CT scanning technique. However, image quality with the sequential technique was statistically significantly superior (P <.05).
A new approach to develop computer-aided detection schemes of digital mammograms
NASA Astrophysics Data System (ADS)
Tan, Maxine; Qian, Wei; Pu, Jiantao; Liu, Hong; Zheng, Bin
2015-06-01
The purpose of this study is to develop a new global mammographic image feature analysis based computer-aided detection (CAD) scheme and evaluate its performance in detecting positive screening mammography examinations. A dataset that includes images acquired from 1896 full-field digital mammography (FFDM) screening examinations was used in this study. Among them, 812 cases were positive for cancer and 1084 were negative or benign. After segmenting the breast area, a computerized scheme was applied to compute 92 global mammographic tissue density based features on each of four mammograms of the craniocaudal (CC) and mediolateral oblique (MLO) views. After adding three existing popular risk factors (woman’s age, subjectively rated mammographic density, and family breast cancer history) into the initial feature pool, we applied a sequential forward floating selection feature selection algorithm to select relevant features from the bilateral CC and MLO view images separately. The selected CC and MLO view image features were used to train two artificial neural networks (ANNs). The results were then fused by a third ANN to build a two-stage classifier to predict the likelihood of the FFDM screening examination being positive. CAD performance was tested using a ten-fold cross-validation method. The computed area under the receiver operating characteristic curve was AUC = 0.779 ± 0.025 and the odds ratio monotonically increased from 1 to 31.55 as CAD-generated detection scores increased. The study demonstrated that this new global image feature based CAD scheme had a relatively higher discriminatory power to cue the FFDM examinations with high risk of being positive, which may provide a new CAD-cueing method to assist radiologists in reading and interpreting screening mammograms.
An Exploratory Study of Residents' Perception of Place Image: The Case of Kavala.
Stylidis, Dimitrios; Sit, Jason; Biran, Avital
2016-05-01
Studies on place image have predominantly focused on the tourists' destination image and have given limited attention to other stakeholders' perspectives. This study aims to address this gap by focusing on the notion of residents' place image, whereby it reviews existing literature on residents' place image in terms of whether common attributes can be identified, and examines the role of community-focused attributes in its measurement. Data collected from a sample of 481 Kavala residents (Greece) were subjected to exploratory and confirmatory factor analysis. The study reveals that the existing measurement tools have typically emphasized destination-focused attributes and neglected community-focused attributes. This study contributes to the residents' place image research by proposing a more holistic measurement, which consisted of four dimensions: physical appearance, community services, social environment, and entertainment opportunities. The study also offers practical insights for developing and promoting a tourist place while simultaneously enhancing its residents' quality of life.
An Exploratory Study of Residents’ Perception of Place Image
Stylidis, Dimitrios; Sit, Jason; Biran, Avital
2014-01-01
Studies on place image have predominantly focused on the tourists’ destination image and have given limited attention to other stakeholders’ perspectives. This study aims to address this gap by focusing on the notion of residents’ place image, whereby it reviews existing literature on residents’ place image in terms of whether common attributes can be identified, and examines the role of community-focused attributes in its measurement. Data collected from a sample of 481 Kavala residents (Greece) were subjected to exploratory and confirmatory factor analysis. The study reveals that the existing measurement tools have typically emphasized destination-focused attributes and neglected community-focused attributes. This study contributes to the residents’ place image research by proposing a more holistic measurement, which consisted of four dimensions: physical appearance, community services, social environment, and entertainment opportunities. The study also offers practical insights for developing and promoting a tourist place while simultaneously enhancing its residents’ quality of life. PMID:29708109
The Implicit Relational Assessment Procedure as a Measure of Self-Esteem
ERIC Educational Resources Information Center
Timko, C. Alix; England, Erica L.; Herbert, James D.; Forman, Evan M.
2010-01-01
Two studies were conducted to pilot the Implicit Relational Assessment Procedure (IRAP) in measuring attitudes toward the self: one related to body image specifically and another assessing the broader construct of self-esteem. Study 1 utilized the IRAP with female college students to examine self-referential beliefs regarding body image. Results…
All Female Education: Self Image and Academic Success of Fourth through Eighth Grade Girls.
ERIC Educational Resources Information Center
Heffernan, Erin J.
This study examines how young women in single sex institutions perceive their educational experience in four categories: academics, resources, participation, and self-image. When investigating whether there are advantages in all female education, it is important to consider student perceptions within these all female schools. This study was…
Information Seeking Behavior in Digital Image Collections: A Cognitive Approach
ERIC Educational Resources Information Center
Matusiak, Krystyna K.
2006-01-01
Presents the results of a qualitative study that focuses on search patterns of college students and community users interacting with a digital image collection. The study finds a distinct difference between the two groups of users and examines the role of mental models in information seeking behavior in digital libraries.
Sundling, Vibeke; Gulbrandsen, Pål; Straand, Jørund
2013-01-10
In the working age group, diabetic retinopathy is a leading cause of visual impairment. Regular eye examinations and early treatment of retinopathy can prevent visual loss, so screening for diabetic retinopathy is cost-effective. Dilated retinal digital photography with the additional use of ophthalmoscopy is the most effective and robust method of diabetic retinopathy screening. The aim of this study was to estimate the sensitivity and specificity of diabetic retinopathy screening when performed by Norwegian optometrists. This study employed a cross-sectional experimental design. Seventy-four optometrists working in private optometric practice were asked to screen 14 single-field retinal images for possible diabetic retinopathy. The screening was undertaken using a web-based visual identification and management of ophthalmological conditions (VIMOC) examination. The images used in the VIMOC examination were selected from a population survey and had been previously examined by two independent ophthalmologists. In order to establish a "gold standard", images were only chosen for use in the VIMOC examination if they had elicited diagnostic agreement between the two independent ophthalmologists. To reduce the possibility of falsely high specificity occurring by chance, half the presented images were of retinas that were not affected by diabetic retinopathy. Sensitivity and specificity for diabetic retinopathy was calculated with 95% confidence intervals (CIs). The mean (95%CI) sensitivity for identifying eyes with any diabetic retinopathy was 67% (62% to 72%). The mean (95%CI) specificity for identifying eyes without diabetic retinopathy was 84% (80% to 89%). The mean (95%CI) sensitivity for identifying eyes with mild non-proliferative diabetic retinopathy or moderate non-proliferative diabetes was 54% (47% to 61%) and 100%, respectively. Only four optometrists (5%) met the required standard of at least 80% sensitivity and 95% specificity that has been previously set for diabetic retinopathy screening programmes. The evaluation of retinal images for diabetic retinopathy by Norwegian optometrists does not meet the required screening standard of at least 80% sensitivity and 95% specificity. The introduction of measures to improve this situation could have implications for both formal optometric training and continuing optometric professional education.
2013-01-01
Background In the working age group, diabetic retinopathy is a leading cause of visual impairment. Regular eye examinations and early treatment of retinopathy can prevent visual loss, so screening for diabetic retinopathy is cost-effective. Dilated retinal digital photography with the additional use of ophthalmoscopy is the most effective and robust method of diabetic retinopathy screening. The aim of this study was to estimate the sensitivity and specificity of diabetic retinopathy screening when performed by Norwegian optometrists. Methods This study employed a cross-sectional experimental design. Seventy-four optometrists working in private optometric practice were asked to screen 14 single-field retinal images for possible diabetic retinopathy. The screening was undertaken using a web-based visual identification and management of ophthalmological conditions (VIMOC) examination. The images used in the VIMOC examination were selected from a population survey and had been previously examined by two independent ophthalmologists. In order to establish a “gold standard”, images were only chosen for use in the VIMOC examination if they had elicited diagnostic agreement between the two independent ophthalmologists. To reduce the possibility of falsely high specificity occurring by chance, half the presented images were of retinas that were not affected by diabetic retinopathy. Sensitivity and specificity for diabetic retinopathy was calculated with 95% confidence intervals (CIs). Results The mean (95%CI) sensitivity for identifying eyes with any diabetic retinopathy was 67% (62% to 72%). The mean (95%CI) specificity for identifying eyes without diabetic retinopathy was 84% (80% to 89%). The mean (95%CI) sensitivity for identifying eyes with mild non-proliferative diabetic retinopathy or moderate non-proliferative diabetes was 54% (47% to 61%) and 100%, respectively. Only four optometrists (5%) met the required standard of at least 80% sensitivity and 95% specificity that has been previously set for diabetic retinopathy screening programmes. Conclusions The evaluation of retinal images for diabetic retinopathy by Norwegian optometrists does not meet the required screening standard of at least 80% sensitivity and 95% specificity. The introduction of measures to improve this situation could have implications for both formal optometric training and continuing optometric professional education. PMID:23305337
Transthoracic needle biopsy of the lung
DiBardino, David M.; Yarmus, Lonny B.
2015-01-01
Background Image guided transthoracic needle aspiration (TTNA) is a valuable tool used for the diagnosis of countless thoracic diseases. Computed tomography (CT) is the most common imaging modality used for guidance followed by ultrasound (US) for lesions abutting the pleural surface. Novel approaches using virtual CT guidance have recently been introduced. The objective of this review is to examine the current literature for TTNA biopsy of the lung focusing on diagnostic accuracy and safety. Methods MEDLINE was searched from inception to October 2015 for all case series examining image guided TTNA. Articles focusing on fluoroscopic guidance as well as influence of rapid on-site evaluation (ROSE) on yield were excluded. The diagnostic accuracy, defined as the number of true positives divided by the number of biopsies done, as well as the complication rate [pneumothorax (PTX), bleeding] was examined for CT guided TTNA, US guided TTNA as well as CT guided electromagnetic navigational-TTNA (E-TTNA). Of the 490 articles recovered 75 were included in our analysis. Results The overall pooled diagnostic accuracy for CT guided TTNA using 48 articles that met the inclusion and exclusion criteria was 92.1% (9,567/10,383). A similar yield was obtained examining ten articles using US guided TTNA of 88.7% (446/503). E-TTNA, being a new modality, only had one pilot study citing a diagnostic accuracy of 83% (19/23). Pooled PTX and hemorrhage rates were 20.5% and 2.8% respectively for CT guided TTNA. The PTX rate was lower in US guided TTNA at a pooled rate of 4.4%. E-TTNA showed a similar rate of PTX at 20% with no incidence of bleeding in a single pilot study available. Conclusions Image guided TTNA is a safe and accurate modality for the biopsy of lung pathology. This study found similar yield and safety profiles with the three imaging modalities examined. PMID:26807279
Dynamic contrast-enhanced breast MRI at 7 Tesla utilizing a single-loop coil: a feasibility trial.
Umutlu, Lale; Maderwald, Stefan; Kraff, Oliver; Theysohn, Jens M; Kuemmel, Sherko; Hauth, Elke A; Forsting, Michael; Antoch, Gerald; Ladd, Mark E; Quick, Harald H; Lauenstein, Thomas C
2010-08-01
The aim of this study was to assess the feasibility of dynamic contrast-enhanced ultra-high-field breast imaging at 7 Tesla. A total of 15 subjects, including 5 patients with histologically proven breast cancer, were examined on a 7 Tesla whole-body magnetic resonance imaging system using a unilateral linearly polarized single-loop coil. Subjects were placed in prone position on a biopsy support system, with the coil placed directly below the region of interest. The examination protocol included the following sequences: 1) T2-weighted turbo spin echo sequence; 2) six dynamic T1-weighted spoiled gradient-echo sequences; and 3) subtraction imaging. Contrast-enhanced T1-weighted imaging at 7 Tesla could be obtained at high spatial resolution with short acquisition times, providing good image accuracy and a conclusively good delineation of small anatomical and pathological structures. T2-weighted imaging could be obtained with high spatial resolution at adequate acquisition times. Because of coil limitations, four high-field magnetic resonance examinations showed decreased diagnostic value. This first scientific approach of dynamic contrast-enhanced breast magnetic resonance imaging at 7 Tesla demonstrates the complexity of ultra-high-field breast magnetic resonance imaging and countenances the implementation of further advanced bilateral coil concepts to circumvent current limitations from the coil and ultra-high-field magnetic strength. 2010 AUR. Published by Elsevier Inc. All rights reserved.
Internal derangement of the knee after ipsilateral femoral shaft fracture: MR imaging findings.
Blacksin, M F; Zurlo, J V; Levy, A S
1998-08-01
This study uses magnetic resonance (MR) imaging to delineate the types and frequencies of injuries seen in the knee after ipsilateral femoral shaft fracture. We also compare the results of the orthopedic knee examination with the MR findings. MR imaging of the ipsilateral knee was performed on 34 patients with closed femoral shaft fractures. Indications for knee MR imaging included knee pain at the time of fracture, soft tissue swelling or an effusion of the knee, or a positive knee examination under anesthesia. The patients had a mean age of 27 years and all were stabilized with intramedullary nails. Imaging was performed a mean time of 2.5 days after surgery. All patients had knee examinations done under anesthesia, and the MR results were compiled and compared with the clinical examinations. Ninety-seven percent of patients demonstrated knee effusions. Twenty-seven percent of patients demonstrated meniscal tears, with the posterior horn of the medial meniscus most frequently torn. The medial collateral ligament was the most frequent site of ligamentous injury (38%) followed by the posterior cruciate ligament (21%). Fifty percent of patients had injuries of the extensor mechanism. Bone bruises were noted in 32% of patients. Articular cartilage injuries were confined to the patella in four cases. One occult tibial plateau fracture and one meniscocapsular separation were seen. There is a common incidence of both ligamentous and meniscal injury to the knee after ipsilateral femoral shaft fracture. MR imaging can be useful in assessing the extent of injury, and may reveal findings unsuspected after clinical examination of the knee.
Application and Miniaturization of Linear and Nonlinear Raman Microscopy for Biomedical Imaging
NASA Astrophysics Data System (ADS)
Mittal, Richa
Current diagnostics for several disorders rely on surgical biopsy or evaluation of ex vivo bodily fluids, which have numerous drawbacks. We evaluated the potential for vibrational techniques (both linear and nonlinear Raman) as a reliable and noninvasive diagnostic tool. Raman spectroscopy is an optical technique for molecular analysis that has been used extensively in various biomedical applications. Based on demonstrated capabilities of Raman spectroscopy we evaluated the potential of the technique for providing a noninvasive diagnosis of mucopolysaccharidosis (MPS). These studies show that Raman spectroscopy can detect subtle changes in tissue biochemistry. In applications where sub-micrometer visualization of tissue compositional change is required, a transition from spectroscopy to high quality imaging is necessary. Nonlinear vibrational microscopy is sensitive to the same molecular vibrations as linear Raman, but features fast imaging capabilities. Coherent Raman scattering when combined with other nonlinear optical (NLO) techniques (like two-photon excited fluorescence and second harmonic generation) forms a collection of advanced optical techniques that provide noninvasive chemical contrast at submicron resolution. This capability to examine tissues without external molecular agents is driving the NLO approach towards clinical applications. However, the unique imaging capabilities of NLO microscopy are accompanied by complex instrument requirements. Clinical examination requires portable imaging systems for rapid inspection of tissues. Optical components utilized in NLO microscopy would then need substantial miniaturization and optimization to enable in vivo use. The challenges in designing compact microscope objective lenses and laser beam scanning mechanisms are discussed. The development of multimodal NLO probes for imaging oral cavity tissue is presented. Our prototype has been examined for ex vivo tissue imaging based on intrinsic fluorescence and SHG contrast. These studies show a potential for multiphoton compact probes to be used for real time imaging in the clinic.
Virtual guidance as a tool to obtain diagnostic ultrasound for spaceflight and remote environments.
Martin, David S; Caine, Timothy L; Matz, Timothy; Lee, Stuart M C; Stenger, Michael B; Sargsyan, Ashot E; Platts, Steven H
2012-10-01
With missions planned to travel greater distances from Earth at ranges that make real-time two-way communication impractical, astronauts will be required to perform autonomous medical diagnostic procedures during future exploration missions. Virtual guidance is a form of just-in-time training developed to allow novice ultrasound operators to acquire diagnostically-adequate images of clinically relevant anatomical structures using a prerecorded audio/visual tutorial viewed in real-time. Individuals without previous experience in ultrasound were recruited to perform carotid artery (N = 10) and ophthalmic (N = 9) ultrasound examinations using virtual guidance as their only training tool. In the carotid group, each untrained operator acquired two-dimensional, pulsed and color Doppler of the carotid artery. In the ophthalmic group, operators acquired representative images of the anterior chamber of the eye, retina, optic nerve, and nerve sheath. Ultrasound image quality was evaluated by independent imaging experts. Of the studies, 8 of the 10 carotid and 17 of 18 of the ophthalmic images (2 images collected per study) were judged to be diagnostically adequate. The quality of all but one of the ophthalmic images ranged from adequate to excellent. Diagnostically-adequate carotid and ophthalmic ultrasound examinations can be obtained by previously untrained operators with assistance from only an audio/video tutorial viewed in real time while scanning. This form of just-in-time training, which can be applied to other examinations, represents an opportunity to acquire important information for NASA flight surgeons and researchers when trained medical personnel are not available or when remote guidance is impractical.
Features and limitations of mobile tablet devices for viewing radiological images.
Grunert, J H
2015-03-01
Mobile radiological image display systems are becoming increasingly common, necessitating a comparison of the features of these systems, specifically the operating system employed, connection to stationary PACS, data security and rang of image display and image analysis functions. In the fall of 2013, a total of 17 PACS suppliers were surveyed regarding the technical features of 18 mobile radiological image display systems using a standardized questionnaire. The study also examined to what extent the technical specifications of the mobile image display systems satisfy the provisions of the Germany Medical Devices Act as well as the provisions of the German X-ray ordinance (RöV). There are clear differences in terms of how the mobile systems connected to the stationary PACS. Web-based solutions allow the mobile image display systems to function independently of their operating systems. The examined systems differed very little in terms of image display and image analysis functions. Mobile image display systems complement stationary PACS and can be used to view images. The impacts of the new quality assurance guidelines (QS-RL) as well as the upcoming new standard DIN 6868 - 157 on the acceptance testing of mobile image display units for the purpose of image evaluation are discussed. © Georg Thieme Verlag KG Stuttgart · New York.
Clinical Application of Cone Beam Computed Tomography of the Rabbit Head: Part 2—Dental Disease
Riggs, G. G.; Cissell, Derek D.; Arzi, Boaz; Hatcher, David C.; Kass, Philip H.; Zhen, Amy; Verstraete, Frank J. M.
2017-01-01
Domestic rabbits are increasing in popularity as household pets; therefore, veterinarians need to be familiar with the most common diseases afflicting rabbits including dental disease. Current diagnostic approaches include gross oral examination, endoscopic oral examination, skull radiography, and computed tomography (CT). Cone beam computed tomography (CBCT), a new oral and maxillofacial imaging modality that has the capability to produce high-resolution images, has not yet been described for use in evaluating dental disease in rabbits. A total of 15 client-owned rabbits had CBCT, oral examination, dental charting, and dental treatment performed under general anesthesia. Images were evaluated using transverse and custom multiplanar (MPR), 3D, and panoramic reconstructed images. The CBCT findings were grouped into abnormalities that could be detected on conscious oral examination vs. abnormalities that could not be detected by conscious oral examination. Potential associations between the two categories were examined by pairwise Fisher’s exact test with statistical significance determined by P < 0.05. The most common findings identified on CBCT images were periodontal ligament space widening (14/15), premolar and molar malocclusion (13/15), apical elongation (13/15), coronal elongation (12/15), inflammatory tooth resorption (12/15), periapical lucency (11/15), moth-eaten pattern of osteolysis of the alveolar bone (9/15), ventral mandibular border contour changes (9/15), and missing teeth (8/15). Of the CBCT abnormalities likely to be observed on oral examination, coronal elongation (detectable on oral examination) was significantly associated with apical elongation (P = 0.029). There were no other significant associations between CBCT findings that are also clinically detectable and CBCT findings that are not be detectable on oral examination. This suggests that pathology often exists that is not apparent upon oral examination. This study establishes the common CBCT findings associated with dental disease in rabbits and demonstrates the feasibility of this technology to diagnose and plan treatment in dental disorders in this species. PMID:28194401
Pujol, Esteban; Van Bree, Henri; Cauzinille, Laurent; Poncet, Cyrill; Gielen, Ingrid; Bouvy, Bernard
2011-06-01
To investigate the use of low-field magnetic resonance imaging (MRI) and MR arthrography in normal canine stifles and to compare MRI images to gross dissection. Descriptive study. Adult canine pelvic limbs (n=17). Stifle joints from 12 dogs were examined by orthopedic and radiographic examination, synovial fluid analysis, and MRI performed using a 0.2 T system. Limbs 1 to 7 were used to develop the MR and MR arthrography imaging protocol. Limbs 8-17 were studied with the developed MR and MR arthrography protocol and by gross dissection. Three sequences were obtained: T1-weighted spin echo (SE) in sagittal, dorsal, and transverse plane; T2-weighted SE in sagittal plane and T1-gradient echo in sagittal plane. Specific bony and soft tissue structures were easily identifiable with the exception of articular cartilage. The cranial and caudal cruciate ligaments were identified. Medial and lateral menisci were seen as wedge-shaped hypointense areas. MR arthrography permitted further delineation of specific structures. MR images corresponded with gross dissection morphology. With the exception of poor delineation of articular cartilage, a low-field MRI and MR arthrography protocol provides images of adequate quality to assess the normal canine stifle joint. © Copyright 2011 by The American College of Veterinary Surgeons.
[Phantom studies of ultrasound equipment for quality improvement in breast diagnosis].
Madjar, H; Mundinger, A; Lattermann, U; Gufler, H; Prömpeler, H J
1996-04-01
According to the German guidelines for quality control of ultrasonic equipment, the following conditions are required for breast ultrasound: A transducer frequency between 5-7.5 MHz and a minimum field of view of 5 cm. Satisfactory images must be obtained in a depth between 0.5 and 4 cm with a wide tolerance of the focal zones. This allows the use of poor quality equipment which does not produce satisfactory image quality and it excludes a number of high frequency and high resolution transducers with a field of view below 5 cm. This study with a test phantom was performed to define image quality objectively. Sixteen ultrasound instruments in different price categories were used to perform standardized examinations on a breast phantom model 550 (ATS Laboratories, Bridgeport, USA). Contrast and spatial resolution in different penetration depths were investigated on cyst phantoms from 1-4 mm diameter and wire targets with defined distances between 0.5-3 mm 4 investigations reported the images. A positive correlation was seen between price category and image quality. This study demonstrates that transducer frequency and image geometry do not allow sufficient quality control. An improvement of ultrasound diagnosis is only possible if equipment guidelines are based on standard examinations with test phantoms.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeon, Chang Ho; Kim, Bohyoung; Gu, Bon Seung
2013-10-15
Purpose: To modify the preprocessing technique, which was previously proposed, improving compressibility of computed tomography (CT) images to cover the diversity of three dimensional configurations of different body parts and to evaluate the robustness of the technique in terms of segmentation correctness and increase in reversible compression ratio (CR) for various CT examinations.Methods: This study had institutional review board approval with waiver of informed patient consent. A preprocessing technique was previously proposed to improve the compressibility of CT images by replacing pixel values outside the body region with a constant value resulting in maximizing data redundancy. Since the technique wasmore » developed aiming at only chest CT images, the authors modified the segmentation method to cover the diversity of three dimensional configurations of different body parts. The modified version was evaluated as follows. In randomly selected 368 CT examinations (352 787 images), each image was preprocessed by using the modified preprocessing technique. Radiologists visually confirmed whether the segmented region covers the body region or not. The images with and without the preprocessing were reversibly compressed using Joint Photographic Experts Group (JPEG), JPEG2000 two-dimensional (2D), and JPEG2000 three-dimensional (3D) compressions. The percentage increase in CR per examination (CR{sub I}) was measured.Results: The rate of correct segmentation was 100.0% (95% CI: 99.9%, 100.0%) for all the examinations. The median of CR{sub I} were 26.1% (95% CI: 24.9%, 27.1%), 40.2% (38.5%, 41.1%), and 34.5% (32.7%, 36.2%) in JPEG, JPEG2000 2D, and JPEG2000 3D, respectively.Conclusions: In various CT examinations, the modified preprocessing technique can increase in the CR by 25% or more without concerning about degradation of diagnostic information.« less
Tez, Selda; Dener, Cenap; Köktener, Aslý; Caydere, Muzaffer; Tez, Mesut
2008-01-01
The purpose of the study was to evaluate the utility of fine needle aspiration--FNA and cytologic analysis of impalpable complicated breast cysts. We rewieved the imaging findings, aspiration, cytology and biopsy results and followup imaging findings of 246 complicated cysts in 166 women retrospectively. FNA was performed in 169 out of the 246 complicated cysts. Thirtyone lesions were followed-up with US. Surgical biopsy was performed from five lesions. No malignant cells (137 cysts), insufficient cellular material (17 cysts), atypical cells (4 cysts) were seen in cytological examination of the aspirates. None of these lesions were found to represent malignancy at the time of surgical excision and during follow-up. Impalpable complicated breast cysts may be classified as probably benign and can be managed with follow-up imaging studies instead of intervention. Routine cytologic examination is unnecessary if the fluid is not bloody (Tab. 2, Ref. 18). Full Text (Free, PDF) www.bmj.sk.
Schmidt, M J; Langen, N; Klumpp, S; Nasirimanesh, F; Shirvanchi, P; Ondreka, N; Kramer, M
2012-01-01
Although magnetic resonance imaging has been used to examine the brain of domestic ruminants, detailed information relating the precise anatomical features in these species is lacking. In this study the brain structures of calves (Bos taurus domesticus), sheep (Ovis aries), goats (Capra hircus) and a mesaticephalic dog (Canis lupis familiaris) were examined using T2-weighed Turbo Spin Echo sequences; three-dimensional models based on high-resolution gradient echo scans were used to identify brain sulci and gyri in two-dimensional images. The ruminant brains examined were similar in structure and organisation to those of other mammals but particular features included the deep depression of the insula and the pronounced gyri of the cortices, the dominant position of the visual (optic nerve, optic chiasm and rostral colliculus) and olfactory (olfactory bulb, olfactory tracts and piriform lobe) systems, and the relatively large size of the diencephalon. Copyright © 2010 Elsevier Ltd. All rights reserved.
O'Connor, Thomas St James; Walsh-Bowers, Richard; Psychology, Community; Ross, Christopher; Sawchuk, Dana; Hatzipantelis, Maria
2006-01-01
In this qualitative study the authors examine the Scriptural images that 10 Lutheran pastors employed in describing the ethical challenges in the pastor-congregant relationship. The analysis of Scriptural images is part of a larger study on pastors' experiences of a mandatory workshop, "Crossing the Boundaries (CTB),"which is required of Evangelical Lutheran Church in Canada (ELCIC) seminarians. The pastors' images were analyzed from the four perspectives of depth psychology, theology, social ethics, and sociology. In commenting on tensions in the pastors' Scriptural images the authors note commonalities among the four theoretical perspectives and discuss implications for practice and future research.
Margolis, Nathaniel E; Rosenkrantz, Andrew B; Babb, James S; Macari, Michael
2015-10-01
Our aim in this study was to evaluate the effect of the radiologist, technologist, and other examination-related factors on the frequency of recommendations for additional imaging (RAI) during sonographic (US) interpretation. We retrospectively reviewed 719 US reports from a single academic medical center for the presence of RAI. All studies had been interpreted by one of three abdominal radiologists. Examinations were performed at an outpatient radiology facility with no onsite radiologist (n = 299) or at an inpatient emergency department or hospital-based outpatient setting that had an onsite radiologist (n = 420). Possible associations between the frequency of RAI and the presence of an onsite radiologist, location of the examination, body part or region imaged, patient age, technologist performing the exam, and radiologist reading the exam were evaluated. There were significant differences between each pair of radiologists in terms of overall frequency of RAI (p < 0.001) (radiologist 1: 12.0% [22/184]; radiologist 2: 21.6% [78/361]; and radiologist 3: 45.5% [79/174]). In addition, there were statistically significant differences in the frequency of RAI among studies scanned by the 10 different US technologists (13.6%-40.0%, p = 0.03). However, other factors such as patient age, patient sex, US unit, patient location, and radiologist location were not associated with the frequency of RAI (p = 0.15-0.93). The individual radiologist and technologist influenced the frequency of RAI for US examinations, whereas other examination-related factors did not. The observed substantial variability in RAI between radiologists and technologists warrants further study, with consideration of strategies to optimize RAI within US reports. © 2015 Wiley Periodicals, Inc.
Demystifying autofluorescence with excitation scanning hyperspectral imaging
NASA Astrophysics Data System (ADS)
Deal, Joshua; Harris, Bradley; Martin, Will; Lall, Malvika; Lopez, Carmen; Rider, Paul; Boudreaux, Carole; Rich, Thomas; Leavesley, Silas J.
2018-02-01
Autofluorescence has historically been considered a nuisance in medical imaging. Many endogenous fluorophores, specifically, collagen, elastin, NADH, and FAD, are found throughout the human body. Diagnostically, these signals can be prohibitive since they can outcompete signals introduced for diagnostic purposes. Recent advances in hyperspectral imaging have allowed the acquisition of significantly more data in a shorter time period by scanning the excitation spectra of fluorophores. The reduced acquisition time and increased signal-to-noise ratio allow for separation of significantly more fluorophores than previously possible. Here, we propose to utilize excitation-scanning of autofluorescence to examine tissues and diagnose pathologies. Spectra of autofluorescent molecules were obtained using a custom inverted microscope (TE-2000, Nikon Instruments) with a Xe arc lamp and thin film tunable filter array (VersaChrome, Semrock, Inc.) Scans utilized excitation wavelengths from 360 nm to 550 nm in 5 nm increments. The resultant spectra were used to examine hyperspectral image stacks from various collaborative studies, including an atherosclerotic rat model and a colon cancer study. Hyperspectral images were analyzed with ENVI and custom Matlab scripts including linear spectral unmixing (LSU) and principal component analysis (PCA). Initial results suggest the ability to separate the signals of endogenous fluorophores and measure the relative concentrations of fluorophores among healthy and diseased states of similar tissues. These results suggest pathology-specific changes to endogenous fluorophores can be detected using excitationscanning hyperspectral imaging. Future work will expand the library of pure molecules and will examine more defined disease states.
Barua, Animesh; Yellapa, Aparna; Bahr, Janice M; Machado, Sergio A; Bitterman, Pincas; Basu, Sanjib; Sharma, Sameer; Abramowicz, Jacques S
2015-07-01
Tumor-associated neoangiogenesis (TAN) is an early event in ovarian cancer (OVCA) development. Increased expression of vascular endothelial growth factor receptor 2 (VEGFR2) by TAN vessels presents a potential target for early detection by ultrasound imaging. The goal of this study was to examine the suitability of VEGFR2-targeted ultrasound contrast agents in detecting spontaneous OVCA in laying hens. Effects of VEGFR2-targeted contrast agents in enhancing the intensity of ultrasound imaging from spontaneous ovarian tumors in hens were examined in a cross-sectional study. Enhancement in the intensity of ultrasound imaging was determined before and after injection of VEGFR2-targeted contrast agents. All ultrasound images were digitally stored and analyzed off-line. Following scanning, ovarian tissues were collected and processed for histology and detection of VEGFR2-expressing microvessels. Enhancement in visualization of ovarian morphology was detected by gray-scale imaging following injection of VEGFR2-targeted contrast agents. Compared with pre-contrast, contrast imaging enhanced the intensities of ultrasound imaging significantly (p < 0.0001) irrespective of the pathological status of ovaries. In contrast to normal hens, the intensity of ultrasound imaging was significantly (p < 0.0001) higher in hens with early stage OVCA and increased further in hens with late stage OVCA. Higher intensities of ultrasound imaging in hens with OVCA were positively correlated with increased (p < 0.0001) frequencies of VEGFR2-expressing microvessels. The results of this study suggest that VEGFR2-targeted contrast agents enhance the visualization of spontaneous ovarian tumors in hens at early and late stages of OVCA. The laying hen may be a suitable model to test new imaging agents and develop targeted therapeutics. © The Author(s) 2014.
Kuehlmann, Britta; Prantl, Lukas; Michael Jung, Ernst
2016-01-01
To investigate whether there are fundamental sonographic and elastographic criteria to precisely assess different surfaces and fillings of idle breast implants and to determine their most distinctive parameters. This was a comparative study of different unused breast implant materials, neighter in animals nor in humans. This knowledge should be transferred in vivo to develop an objective measurement tool. Nine idle breast implants-silicone and polyurethane (PU)-were examined in an experimental study by using ultrasound B-mode with tissue harmonic imaging (THI), speckle reduction imaging (SRI, level 0-4), cross-beam (CB, low, medium, high), photopic and the colour coded ultrasound-strain elastography with a multifrequency probe (9-15 MHz).Using a standardised protocol the implants' centre as well as the edge were analysed by one experienced examiner. Two independent readers performed analysis and evaluation. For image interpretation a score was created (score 0:inadequate image, score 5:best image quality). The highest score result for the centre was achieved by using ultrasound with B-mode in addition with CB level medium, SRI level 2, THI and photopic (mean:3.22±SD:1.56), but without any statistic significant difference (t-value = 0.71). With elastography the implants' edge in general was represented without disruptive artefacts (3.89±0.60) with statistic significant difference (t-value = 5.29). Implants filled with inner cohesive silicone gel II° showed best imaging conditions for their centre via ultrasound (5±0) as well as for their edge via elastography (4.50±0.71). Ultrasound-strain elastography and high resolution ultrasound represent a valuable measurement tool to evaluate different properties of idle breast implants. These modified ultrasound examinations could be an additional help for clinical investigations and be correlated with Baker's Classification.
... specific information about your own examination. What is magnetic resonance imaging (MRI)? What is MRI used for? How safe ... What is the MRI examination like? What is magnetic resonance imaging (MRI)? MRI, or magnetic resonance imaging, is a ...
Impact of lossy compression on diagnostic accuracy of radiographs for periapical lesions
NASA Technical Reports Server (NTRS)
Eraso, Francisco E.; Analoui, Mostafa; Watson, Andrew B.; Rebeschini, Regina
2002-01-01
OBJECTIVES: The purpose of this study was to evaluate the lossy Joint Photographic Experts Group compression for endodontic pretreatment digital radiographs. STUDY DESIGN: Fifty clinical charge-coupled device-based, digital radiographs depicting periapical areas were selected. Each image was compressed at 2, 4, 8, 16, 32, 48, and 64 compression ratios. One root per image was marked for examination. Images were randomized and viewed by four clinical observers under standardized viewing conditions. Each observer read the image set three times, with at least two weeks between each reading. Three pre-selected sites per image (mesial, distal, apical) were scored on a five-scale score confidence scale. A panel of three examiners scored the uncompressed images, with a consensus score for each site. The consensus score was used as the baseline for assessing the impact of lossy compression on the diagnostic values of images. The mean absolute error between consensus and observer scores was computed for each observer, site, and reading session. RESULTS: Balanced one-way analysis of variance for all observers indicated that for compression ratios 48 and 64, there was significant difference between mean absolute error of uncompressed and compressed images (P <.05). After converting the five-scale score to two-level diagnostic values, the diagnostic accuracy was strongly correlated (R (2) = 0.91) with the compression ratio. CONCLUSION: The results of this study suggest that high compression ratios can have a severe impact on the diagnostic quality of the digital radiographs for detection of periapical lesions.
Clinical study of imaging skin cancer margins using polarized light imaging
NASA Astrophysics Data System (ADS)
Samatham, Ravikant; Lee, Ken; Jacques, Steven L.
2012-02-01
Skin cancer is most commons type of cancer in United States that occur on sun-exposed cosmetically sensitive areas like face, neck, and forearms. Surgical excision of skin cancer is challenging as more than one-third the actual margins extend beyond the clinically determined margins. Polarized light camera (polCAM) provides images of the superficial layers of the tissue with enhanced contrast which was used to image skin cancer margins. In a NIH-funded pilot study polCAM was used to image skin cancer in patients undergoing Mohs micrographic surgery for skin cancer. Polarized light imaging utilizes the polarization properties of light to create an image of a lesion comprised only of light scattering from the superficial layers of the skin which yields a characteristic "fabric pattern" of the putative lesion and the surrounding normal tissue. In several case studies conducted with a system developed for the clinic, we have found that skin cancer disrupts this fabric pattern, allowing the doctor a new means of identifying the margins of the lesion. Data is acquired before the patient underwent surgery. The clinically determined skin cancer margins were compared with margins determined by examination of the polCAM images. The true margins were provided by the dermatophathologist on examination of the frozen sections. Our initial data suggests that the contrast due to polarization changes associated with cancerous lesions can elucidate margins that were not recognized by the surgeon under normal conditions but were later confirmed by the pathologist.
Challenging previous conceptions of vegetarianism and eating disorders.
Fisak, B; Peterson, R D; Tantleff-Dunn, S; Molnar, J M
2006-12-01
The purpose of this study was to replicate and expand upon previous research that has examined the potential association between vegetarianism and disordered eating. Limitations of previous research studies are addressed, including possible low reliability of measures of eating pathology within vegetarian samples, use of only a few dietary restraint measures, and a paucity of research examining potential differences in body image and food choice motives of vegetarians versus nonvegetarians. Two hundred and fifty-six college students completed a number of measures of eating pathology and body image, and a food choice motives questionnaire. Interestingly, no significant differences were found between vegetarians and nonvegetarians in measures of eating pathology or body image. However, significant differences in food choice motives were found. Implications for both researchers and clinicians are discussed.
Genova, Helen M.; Rajagopalan, Venkateswaran; DeLuca, John; Das, Abhijit; Binder, Allison; Arjunan, Aparna; Chiaravalloti, Nancy; Wylie, Glenn
2013-01-01
The present study investigated the neural correlates of cognitive fatigue in Multiple Sclerosis (MS), looking specifically at the relationship between self-reported fatigue and objective measures of cognitive fatigue. In Experiment 1, functional magnetic resonance imaging (fMRI) was used to examine where in the brain BOLD activity covaried with “state” fatigue, assessed during performance of a task designed to induce cognitive fatigue while in the scanner. In Experiment 2, diffusion tensor imaging (DTI) was used to examine where in the brain white matter damage correlated with increased “trait” fatigue in individuals with MS, assessed by the Fatigue Severity Scale (FSS) completed outside the scanning session. During the cognitively fatiguing task, the MS group had increased brain activity associated with fatigue in the caudate as compared with HCs. DTI findings revealed that reduced fractional anisotropy in the anterior internal capsule was associated with increased self-reported fatigue on the FSS. Results are discussed in terms of identifying a “fatigue-network” in MS. PMID:24223850
Genova, Helen M; Rajagopalan, Venkateswaran; Deluca, John; Das, Abhijit; Binder, Allison; Arjunan, Aparna; Chiaravalloti, Nancy; Wylie, Glenn
2013-01-01
The present study investigated the neural correlates of cognitive fatigue in Multiple Sclerosis (MS), looking specifically at the relationship between self-reported fatigue and objective measures of cognitive fatigue. In Experiment 1, functional magnetic resonance imaging (fMRI) was used to examine where in the brain BOLD activity covaried with "state" fatigue, assessed during performance of a task designed to induce cognitive fatigue while in the scanner. In Experiment 2, diffusion tensor imaging (DTI) was used to examine where in the brain white matter damage correlated with increased "trait" fatigue in individuals with MS, assessed by the Fatigue Severity Scale (FSS) completed outside the scanning session. During the cognitively fatiguing task, the MS group had increased brain activity associated with fatigue in the caudate as compared with HCs. DTI findings revealed that reduced fractional anisotropy in the anterior internal capsule was associated with increased self-reported fatigue on the FSS. Results are discussed in terms of identifying a "fatigue-network" in MS.
Gallium 68 PSMA-11 PET/MR Imaging in Patients with Intermediate- or High-Risk Prostate Cancer.
Park, Sonya Youngju; Zacharias, Claudia; Harrison, Caitlyn; Fan, Richard E; Kunder, Christian; Hatami, Negin; Giesel, Frederik; Ghanouni, Pejman; Daniel, Bruce; Loening, Andreas M; Sonn, Geoffrey A; Iagaru, Andrei
2018-05-16
Purpose To report the results of dual-time-point gallium 68 ( 68 Ga) prostate-specific membrane antigen (PSMA)-11 positron emission tomography (PET)/magnetic resonance (MR) imaging prior to prostatectomy in patients with intermediate- or high-risk cancer. Materials and Methods Thirty-three men who underwent conventional imaging as clinically indicated and who were scheduled for radical prostatectomy with pelvic lymph node dissection were recruited for this study. A mean dose of 4.1 mCi ± 0.7 (151.7 MBq ± 25.9) of 68 Ga-PSMA-11 was administered. Whole-body images were acquired starting 41-61 minutes after injection by using a GE SIGNA PET/MR imaging unit, followed by an additional pelvic PET/MR imaging acquisition at 87-125 minutes after injection. PET/MR imaging findings were compared with findings at multiparametric MR imaging (including diffusion-weighted imaging, T2-weighted imaging, and dynamic contrast material-enhanced imaging) and were correlated with results of final whole-mount pathologic examination and pelvic nodal dissection to yield sensitivity and specificity. Dual-time-point metabolic parameters (eg, maximum standardized uptake value [SUV max ]) were compared by using a paired t test and were correlated with clinical and histopathologic variables including prostate-specific antigen level, Gleason score, and tumor volume. Results Prostate cancer was seen at 68 Ga-PSMA-11 PET in all 33 patients, whereas multiparametric MR imaging depicted Prostate Imaging Reporting and Data System (PI-RADS) 4 or 5 lesions in 26 patients and PI-RADS 3 lesions in four patients. Focal uptake was seen in the pelvic lymph nodes in five patients. Pathologic examination confirmed prostate cancer in all patients, as well as nodal metastasis in three. All patients with normal pelvic nodes in PET/MR imaging had no metastases at pathologic examination. The accumulation of 68 Ga-PSMA-11 increased at later acquisition times, with higher mean SUV max (15.3 vs 12.3, P < .001). One additional prostate cancer was identified only at delayed imaging. Conclusion This study found that 68 Ga-PSMA-11 PET can be used to identify prostate cancer, while MR imaging provides detailed anatomic guidance. Hence, 68 Ga-PSMA-11 PET/MR imaging provides valuable diagnostic information and may inform the need for and extent of pelvic node dissection. © RSNA, 2018 Online supplemental material is available for this article.
Kowalska, Berta; Sudoł-Szopińska, Iwona
2012-06-01
The ultrasonographic examination is currently increasingly used in imaging peripheral nerves, serving to supplement the physical examination, electromyography and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive and well-tolerated by patients. The typical ultrasonographic picture of peripheral nerves as well as the examination technique have been discussed in part I of this article series, following the example of the median nerve. Part II of the series presented the normal anatomy and the technique for examining the peripheral nerves of the upper limb. This part of the article series focuses on the anatomy and technique for examining twelve normal peripheral nerves of the lower extremity: the iliohypogastric and ilioinguinal nerves, the lateral cutaneous nerve of the thigh, the pudendal, sciatic, tibial, sural, medial plantar, lateral plantar, common peroneal, deep peroneal and superficial peroneal nerves. It includes diagrams showing the proper positioning of the sonographic probe, plus USG images of the successively discussed nerves and their surrounding structures. The ultrasonographic appearance of the peripheral nerves in the lower limb is identical to the nerves in the upper limb. However, when imaging the lower extremity, convex probes are more often utilized, to capture deeply-seated nerves. The examination technique, similarly to that used in visualizing the nerves of upper extremity, consists of locating the nerve at a characteristic anatomic reference point and tracking it using the "elevator technique". All 3 parts of the article series should serve as an introduction to a discussion of peripheral nerve pathologies, which will be presented in subsequent issues of the "Journal of Ultrasonography".
Sudoł-Szopińska, Iwona
2012-01-01
The ultrasonographic examination is currently increasingly used in imaging peripheral nerves, serving to supplement the physical examination, electromyography and magnetic resonance imaging. As in the case of other USG imaging studies, the examination of peripheral nerves is non-invasive and well-tolerated by patients. The typical ultrasonographic picture of peripheral nerves as well as the examination technique have been discussed in part I of this article series, following the example of the median nerve. Part II of the series presented the normal anatomy and the technique for examining the peripheral nerves of the upper limb. This part of the article series focuses on the anatomy and technique for examining twelve normal peripheral nerves of the lower extremity: the iliohypogastric and ilioinguinal nerves, the lateral cutaneous nerve of the thigh, the pudendal, sciatic, tibial, sural, medial plantar, lateral plantar, common peroneal, deep peroneal and superficial peroneal nerves. It includes diagrams showing the proper positioning of the sonographic probe, plus USG images of the successively discussed nerves and their surrounding structures. The ultrasonographic appearance of the peripheral nerves in the lower limb is identical to the nerves in the upper limb. However, when imaging the lower extremity, convex probes are more often utilized, to capture deeply-seated nerves. The examination technique, similarly to that used in visualizing the nerves of upper extremity, consists of locating the nerve at a characteristic anatomic reference point and tracking it using the “elevator technique”. All 3 parts of the article series should serve as an introduction to a discussion of peripheral nerve pathologies, which will be presented in subsequent issues of the “Journal of Ultrasonography”. PMID:26674560
Ogedegbe, Chinwe; Morchel, Herman; Hazelwood, Vikki; Chaplin, William F; Feldman, Joseph
2012-12-18
Despite the use of e-FAST in management of patients with abdominal trauma, its utility in prehospital setting is not widely adopted. The goal of this study is to develop a novel portable telesonography (TS) system and evaluate the comparability of the quality of images obtained via this system among healthy volunteers who undergo e-FAST abdominal examination in a moving ambulance and at the ED. We hypothesize that: (1) real-time ultrasound images of acute trauma patients in the pre-hospital setting can be obtained and transmitted to the ED via the novel TS system; and (2) Ultrasound images transmitted to the hospital from the real-time TS system will be comparable in quality to those obtained in the ED. Study participants are three healthy volunteers (one each with normal, overweight and obese BMI category). The ultrasound images will be obtained by two ultrasound-trained physicians The TS is a portable sonogram (by Sonosite) interfaced with a portable broadcast unit (by Live-U). Two UTPs will conduct e-FAST examinations on healthy volunteers in moving ambulances and transmit the images via cellular network to the hospital server, where they are stored. Upon arrival in the ED, the same UTPs will obtain another set of images from the volunteers, which are then compared to those obtained in the moving ambulances by another set of blinded UTPs (evaluators) using a validated image quality scale, the Questionnaire for User Interaction Satisfaction (QUIS). Findings from this study will provide needed data on the validity of the novel TS in transmitting live images from moving ambulances to images obtained in the ED thus providing opportunity to facilitate medical care of a patient located in a remote or austere setting.
NetTweens: The Internet and Body Image Concerns in Preteenage Girls
ERIC Educational Resources Information Center
Tiggemann, Marika; Slater, Amy
2014-01-01
The aim of the study was to examine the relationship between media exposure and body image concerns in preteenage girls, with a particular focus on the Internet. A sample of 189 girls (aged 10-12 years) completed questionnaire measures of media consumption and body image concerns. Nearly all girls (97.5%) had access to the Internet in their home.…
ERIC Educational Resources Information Center
Schooler, Deborah
2008-01-01
Contextualizing Latina girls' body image development requires an appreciation of mainstream body ideals, Latino/a cultural values, and the process by which Latina girls traverse the borders between them. The current study examines how media use and acculturation act across adolescence to shape the development of body image among Latina girls.…
ERIC Educational Resources Information Center
Heiland, Teresa L.; Murray, Darrin S.; Edley, Paige P.
2008-01-01
Body image and self-esteem are examined through personal stories among Los Angeles college dancers who grew up in the Hollywood culture of the cult of slenderness. The study incorporates a body image survey, eating disorder screen, and an interview process capturing dancers' lived experiences with daily pressures. Dancers reveal their experiences…
Cross-Cultural Examination of Women's Body Image Perception.
ERIC Educational Resources Information Center
Huber, R. John; And Others
The media's portrayal of the ideal body image has been shown to be a large determinant of one's body image perception. The desire to be excessively thin can be conceived of as an artifact of White-American culture largely due to the media's influence. This study looks at cultures that have had limited exposure to the American ideal and examines…
ERIC Educational Resources Information Center
Brausch, Amy M.; Gutierrez, Peter M.
2009-01-01
There is much empirical literature on factors for adolescent suicide risk, but body image and disordered eating are rarely included in these models. In the current study, disordered eating and body image were examined as risk factors for suicide ideation since these factors are prevalent in adolescence, particularly for females. It was…
ERIC Educational Resources Information Center
Ata, Rheanna N.; Ludden, Alison Bryant; Lally, Megan M.
2007-01-01
The current study expands upon body image research to examine how gender, self-esteem, social support, teasing, and family, friend, and media pressures relate to body image and eating-related attitudes and behaviors among male and female adolescents (N = 177). Results indicated that adolescents were dissatisfied with their current bodies: males…
ERIC Educational Resources Information Center
Adegoke, Alfred A.
Noting the lack of self-concept research in nonwestern cultures and the need to determine if a western measure of self-image is embedded in the same network of constructs in another culture, this study examined the appropriateness of using the Self Image Questionnaire for Young Adolescents (SIQYA) with Nigerian students. Participating in the study…
ERIC Educational Resources Information Center
Choi, Jeong-Sil; Kim, Ji-Soo
2017-01-01
Background: We explored the relationship between body mass index-for-age percentile, body image distortion, and unnecessary weight loss efforts in Korean adolescent girls who are underweight and normal weight and examined the mediating effect of body image distortion on weight loss efforts. Methods: This study used data from the 2013 Korea Youth…
ERIC Educational Resources Information Center
Ferrell, Kay Alicyn; Correa-Torres, Silvia M.; Howell, Jennifer Johnson; Pearson, Robert; Carver, Wendy Morrow; Groll, Amy Spencer; Anthony, Tanni L.; Matthews, Deborah; Gould, Bryan; O'Connell, Trisha; Botsford, Kathryn D,; Dewald, Hong Phangia; Smyth, Catherine A.; Dewald, Aaron John
2017-01-01
Introduction:Although image description has been identified as an accommodation for presentations conducted in the classroom, only a few U.S. states have approved it for use in high-stakes assessments. This study examined the use of audible image description as an assessment accommodation for students with visual and print disabilities by…
Persuasive images in popular science: Testing judgments of scientific reasoning and credibility.
Gruber, David; Dickerson, Jacob A
2012-11-01
This article tested the assumption that functional magnetic resonance imaging (fMRI) images in popular science news articles make those articles appear more reasonable and persuasive to readers. In addition to fMRI images, this study also examined the potential impact of science fiction and artistic images commonly found in popular news articles. 183 undergraduates were asked to evaluate one of four versions of an article, each with a different image. The researchers discovered no significant differences between readers' evaluations of the news article with the images isolated as the only independent variable. This suggests that images alone may not have a strong effect upon evaluation, that no image is necessarily more persuasive than another as implied by earlier studies and that further research is needed to determine what, if any, role images play in conjunction with the text to create a persuasive effect.
NASA Astrophysics Data System (ADS)
Okawa, Shinpei; Sei, Kiguna; Hirasawa, Takeshi; Irisawa, Kaku; Hirota, Kazuhiro; Wada, Takatsugu; Kushibiki, Toshihiro; Furuya, Kenichi; Ishihara, Miya
2017-03-01
For diagnosis of cervical cancer, screening by colposcope and successive biopsy are usually carried out. Colposcope, which is a mesoscope, is used to examine surface of the cervix and to find precancerous lesion grossly. However, the accuracy of colposcopy depends on the skills of the examiner and is inconsistent as a result. Additionally, colposcope lacks depth information. It is known that microvessel density and blood flow in cervical lesion increases associated with angiogenesis. Therefore, photoacoustic imaging (PAI) to detect angiogenesis in cervical lesion has been studied. PAI can diagnose cervical lesion sensitively and provide depth information. The authors have been investigating the efficacy of PAI in the diagnoses of the cervical lesion and cancer by use of the PAI and ultrasonography system with transvaginal probe developed by Fujifilm Corporation. For quantitative diagnosis by use of PAI, it is required to take the light propagation in biological medium into account. The image reconstruction of the absorption coefficient from the PA image of cervix by use of the simulation of light propagation based on finite element method has been tried in this study. Numerical simulation, phantom experiment and in vivo imaging were carried out.
Diagnostic discrepancies in retinopathy of prematurity classification
Campbell, J. Peter; Ryan, Michael C.; Lore, Emily; Tian, Peng; Ostmo, Susan; Jonas, Karyn; Chan, R.V. Paul; Chiang, Michael F.
2016-01-01
Objective To identify the most common areas for discrepancy in retinopathy of prematurity (ROP) classification between experts. Design Prospective cohort study. Subjects, Participants, and/or Controls 281 infants were identified as part of a multi-center, prospective, ROP cohort study from 7 participating centers. Each site had participating ophthalmologists who provided the clinical classification after routine examination using binocular indirect ophthalmoscopy (BIO), and obtained wide-angle retinal images, which were independently classified by two study experts. Methods Wide-angle retinal images (RetCam; Clarity Medical Systems, Pleasanton, CA) were obtained from study subjects, and two experts evaluated each image using a secure web-based module. Image-based classifications for zone, stage, plus disease, overall disease category (no ROP, mild ROP, Type II or pre-plus, and Type I) were compared between the two experts, and to the clinical classification obtained by BIO. Main Outcome Measures Inter-expert image-based agreement and image-based vs. ophthalmoscopic diagnostic agreement using absolute agreement and weighted kappa statistic. Results 1553 study eye examinations from 281 infants were included in the study. Experts disagreed on the stage classification in 620/1553 (40%) of comparisons, plus disease classification (including pre-plus) in 287/1553 (18%), zone in 117/1553 (8%), and overall ROP category in 618/1553 (40%). However, agreement for presence vs. absence of type 1 disease was >95%. There were no differences between image-based and clinical classification except for zone III disease. Conclusions The most common area of discrepancy in ROP classification is stage, although inter-expert agreement for clinically-significant disease such as presence vs. absence of type 1 and type 2 disease is high. There were no differences between image-based grading and the clinical exam in the ability to detect clinically-significant disease. This study provides additional evidence that image-based classification of ROP reliably detects clinically significant levels of ROP with high accuracy compared to the clinical exam. PMID:27238376
Analysis of Preoperative Airway Examination with the CMOS Video Rhino-laryngoscope.
Tsukamoto, Masanori; Hitosugi, Takashi; Yokoyama, Takeshi
2017-05-01
Endoscopy is one of the most useful clinical techniques in difficult airway management Comparing with the fibroptic endoscope, this compact device is easy to operate and can provide the clear image. In this study, we investigated its usefulness in the preoperative examination of endoscopy. Patients undergoing oral maxillofacial surgery were enrolled in this study. We performed preoperative airway examination by electronic endoscope (The CMOS video rhino-laryngoscope, KARL STORZ Endoscopy Japan, Tokyo). The system is composed of a videoendoscope, a compact video processor and a video recorder. In addition, the endoscope has a small color charge coupled device (CMOS) chip built into the tip of the endoscope. The outer diameter of the tip of this scope is 3.7 mm. In this study, electronic endoscope was used for preoperative airway examination in 7 patients. The preoperative airway examination with electronic endoscope was performed successfully in all the patients except one patient The patient had the symptoms such as nausea and vomiting at the examination. We could perform preoperative airway examination with excellent visualization and convenient recording of video sequence images with the CMOS video rhino-laryngoscope. It might be a especially useful device for the patients of difficult airways.
Novel Use of Ultrasound to Teach Reproductive System Physical Examination Skills and Pelvic Anatomy.
Parikh, Tejal; Czuzak, Maria; Bui, Naomi; Wildner, Corinna; Koch, Bryna; Leko, Elizabeth; Rappaport, William; Adhikari, Srikar; Gordon, Paul; Gura, Mike; Ellis, Susan
2018-03-01
To determine whether integration of ultrasound (US) into a reproductive system examination clinical skills lab can increase confidence in palpating key reproductive structures during testicular and bimanual pelvic examinations, reduce anxiety about conducting testicular and bimanual pelvic examinations, and improve performance on multiple-choice questions based on structure identification using US images. Second-year medical students enrolled in the Life Cycle preclinical course participated in this cross-sectional study. A single learning activity was developed to pair the teaching of the reproductive system physical examination with the use of US in the clinical skills lab. The evaluation of the teaching session consisted of a pre-post analysis of student self-reported knowledge, confidence, and anxiety. The response rate for the pre survey was 82% (n = 96), and the rate for the post survey was 79% (n = 93). Students' confidence in their ability to identify reproductive system structures on US images increased from pre to post survey. Their confidence in their ability to palpate the epididymis, uterus, and ovary during a physical examination improved, and their anxiety about conducting testicular and bimanual pelvic examinations decreased. Student satisfaction with the session was high. Students' performance on multiple-choice questions based on structure identification using US images was at 96% or higher. Our study findings support the integration of US into a reproductive system examination clinical skills lab. Medical students acquire competency and confidence in reproductive system physical examination skills with US integration. © 2017 by the American Institute of Ultrasound in Medicine.
Kamishima, Tamotsu; Tanimura, Kazuhide; Henmi, Mihoko; Narita, Akihiro; Sakamoto, Fumihiko; Terae, Satoshi; Shirato, Hiroki
2009-05-01
The objective of this study was to assess interobserver uncertainties in power Doppler (PD) examination of the fingers of patients with rheumatoid arthritis (RA), by separating the source of the discrepancy into (1) acquisition of the images and (2) criteria for assessment of the images. Twenty patients who had been diagnosed with RA were enrolled in this study. Ultrasound examinations were performed by one inexperienced and two experienced sonographers. Interobserver variation was measured using a conventional semiquantitative image grading scale. Interobserver variation of the quantitative PD (QPD) index (the summation of the colored pixels in a region of interest) was also assessed. The agreement was higher between the two experienced sonographers (kappa value of 0.8) than between experienced and inexperienced sonographers (kappa value, 0.6-0.7) in the semiquantitative image grading scale. Results suggest that the difference in the assessment on the image grading scale was due more to the difference in the acquisition of the images than to variations in the grading criteria between sonographers. An excellent relationship was noted between the image grading scale and the QPD index for Doppler signal with a Spearman's coefficient of rank correlation of 0.83 (P < 0.0001). Interobserver discrepancies in the image grading and QPD index methods were due more to the difference in the acquisition of the image than to the grading criteria used. The QPD index seems to be as reliable as the image grading scale with reasonable interobserver agreement between experienced sonographers.
ERIC Educational Resources Information Center
Batty, Martin J.; Liddle, Elizabeth B.; Pitiot, Alain; Toro, Roberto; Groom, Madeleine J.; Scerif, Gaia; Liotti, Mario; Liddle, Peter F.; Paus, Tomas; Hollis, Chris
2010-01-01
Objective: Previous studies have shown smaller brain volume and less gray matter in children with attention-deficit/hyperactivity disorder (ADHD). Relatively few morphological studies have examined structures thought to subserve inhibitory control, one of the diagnostic features of ADHD. We examined one such region, the pars opercularis,…
Korn, Liat; Gonen, Ester; Shaked, Yael; Golan, Moria
2013-01-01
Purpose This study examines health perceptions, self and body image, physical exercise and nutrition among undergraduate students. Methods A structured, self-reported questionnaire was administered to more than 1500 students at a large academic institute in Israel. The study population was heterogenic in both gender and fields of academic study. Results High correlations between health perceptions, appropriate nutrition, and positive self and body image were found. The relationships between these variables differed between the subpopulation in the sample and the different genders. Engagement in physical exercise contributed to positive body image and positive health perceptions more than engagement in healthy nutrition. Nutrition students reported higher frequencies of positive health perceptions, positive self and body image and higher engagement in physical exercise in comparison to all other students in the sample. Conclusions This study suggests, as have many before, that successful health promotion policy should reflect a collectivist rather than an individualist ethos by providing health prerequisites through a public policy of health-promotion, where the academic settings support a healthy lifestyle policy, by increasing availability of a healthy, nutritious and varied menu in the cafeterias, and offering students various activities that enhance healthy eating and exercise. Implications and contribution This study examined health perceptions, self-image, physical exercise and nutrition among undergraduate students and found high correlations between these topics. Nutrition students reported higher frequencies of positive health perceptions, and positive self and body image and engaged more in physical exercise when compared with all other students in the sample. PMID:23516503
Mitry, Danny; Peto, Tunde; Hayat, Shabina; Blows, Peter; Morgan, James; Khaw, Kay-Tee; Foster, Paul J
2015-01-01
Crowdsourcing is the process of simplifying and outsourcing numerous tasks to many untrained individuals. Our aim was to assess the performance and repeatability of crowdsourcing in the classification of normal and glaucomatous discs from optic disc images. Optic disc images (N = 127) with pre-determined disease status were selected by consensus agreement from grading experts from a large cohort study. After reading brief illustrative instructions, we requested that knowledge workers (KWs) from a crowdsourcing platform (Amazon MTurk) classified each image as normal or abnormal. Each image was classified 20 times by different KWs. Two study designs were examined to assess the effect of varying KW experience and both study designs were conducted twice for consistency. Performance was assessed by comparing the sensitivity, specificity and area under the receiver operating characteristic curve (AUC). Overall, 2,540 classifications were received in under 24 hours at minimal cost. The sensitivity ranged between 83-88% across both trials and study designs, however the specificity was poor, ranging between 35-43%. In trial 1, the highest AUC (95%CI) was 0.64(0.62-0.66) and in trial 2 it was 0.63(0.61-0.65). There were no significant differences between study design or trials conducted. Crowdsourcing represents a cost-effective method of image analysis which demonstrates good repeatability and a high sensitivity. Optimisation of variables such as reward schemes, mode of image presentation, expanded response options and incorporation of training modules should be examined to determine their effect on the accuracy and reliability of this technique in retinal image analysis.
Self-presentational persona: simultaneous management of multiple impressions.
Leary, Mark R; Allen, Ashley Batts
2011-11-01
Most research on self-presentation has examined how people convey images of themselves on only 1 or 2 dimensions at a time. In everyday interactions, however, people often manage their impressions on several image-relevant dimensions simultaneously. By examining people's self-presentations to several targets across multiple dimensions, these 2 studies offer new insights into the nature of self-presentation and provide a novel paradigm for studying impression management. Results showed that most people rely on a relatively small number of basic self-presentational personas in which they convey particular profiles of impressions as a set and that these personas reflect both normative influences to project images that are appropriate to a particular target and distinctive influences by which people put an idiosyncratic spin on these normative images. Furthermore, although people's self-presentational profiles correlate moderately with their self-views, they tailor their public images to specific targets. The degree to which participants' self-presentations were normative and distinctive, as well as the extent to which they reflected their own self-views, were moderated by individual differences in agreeableness, self-esteem, authenticity, and Machiavellianism.
Detection and Evaluation of Skin Disorders by One of Photogrammetric Image Analysis Methods
NASA Astrophysics Data System (ADS)
Güçin, M.; Patias, P.; Altan, M. O.
2012-08-01
Abnormalities on skin may vary from simple acne to painful wounds which affect a person's life quality. Detection of these kinds of disorders in early stages, followed by the evaluation of abnormalities is of high importance. At this stage, photogrammetry offers a non-contact solution to this concern by providing geometric highly accurate data. Photogrammetry, which has been used for firstly topographic purposes, in virtue of terrestrial photogrammetry became useful technique in non-topographic applications also (Wolf et al., 2000). Moreover the extension of usage of photogrammetry, in parallel with the development in technology, analogue photographs are replaced with digital images and besides digital image processing techniques, it provides modification of digital images by using filters, registration processes etc. Besides, photogrammetry (using same coordinate system by registration of images) can serve as a tool for the comparison of temporal imaging data. The aim of this study is to examine several digital image processing techniques, in particular the digital filters, which might be useful to determine skin disorders. In our study we examine affordable to purchase, user friendly software which needs neither expertise nor pre-training. Since it is a pre-work for subsequent and deeper studies, Adobe Photoshop 7.0 is used as a present software. In addition to that Adobe Photoshop released a DesAcc plug-ins with CS3 version and provides full compatibility with DICOM (Digital Imaging and Communications in Medicine) and PACS (Picture Archiving and Communications System) that enables doctors to store all medical data together with relevant images and share if necessary.
Fink, Christian; Hallscheidt, Peter J; Noeldge, Gerd; Kampschulte, Annette; Radeleff, Boris; Hosch, Waldemar P; Kauffmann, Günter W; Hansmann, Jochen
2002-02-01
The objective of this study was to compare clinical chest radiographs of a large-area, flat-panel digital radiography system and a conventional film-screen radiography system. The comparison was based on an observer preference study of image quality and visibility of anatomic structures. Routine follow-up chest radiographs were obtained from 100 consecutive oncology patients using a large-area, amorphous silicon flat-panel detector digital radiography system (dose equivalent to a 400-speed film system). Hard-copy images were compared with previous examinations of the same individuals taken on a conventional film-screen system (200-speed). Patients were excluded if changes in the chest anatomy were detected or if the time interval between the examinations exceeded 1 year. Observer preference was evaluated for the image quality and the visibility of 15 anatomic structures using a five-point scale. Dose measurements with a chest phantom showed a dose reduction of approximately 50% with the digital radiography system compared with the film-screen radiography system. The image quality and the visibility of all but one anatomic structure of the images obtained with the digital flat-panel detector system were rated significantly superior (p < or = 0.0003) to those obtained with the conventional film-screen radiography system. The image quality and visibility of anatomic structures on the images obtained by the flat-panel detector system were perceived as equal or superior to the images from conventional film-screen chest radiography. This was true even though the radiation dose was reduced approximately 50% with the digital flat-panel detector system.
Le Faivre, Julien; Duhamel, Alain; Khung, Suonita; Faivre, Jean-Baptiste; Lamblin, Nicolas; Remy, Jacques; Remy-Jardin, Martine
2016-11-01
To evaluate the impact of CT perfusion imaging on the detection of peripheral chronic pulmonary embolisms (CPE). 62 patients underwent a dual-energy chest CT angiographic examination with (a) reconstruction of diagnostic and perfusion images; (b) enabling depiction of vascular features of peripheral CPE on diagnostic images and perfusion defects (20 segments/patient; total: 1240 segments examined). The interpretation of diagnostic images was of two types: (a) standard (i.e., based on cross-sectional images alone) or (b) detailed (i.e., based on cross-sectional images and MIPs). The segment-based analysis showed (a) 1179 segments analyzable on both imaging modalities and 61 segments rated as nonanalyzable on perfusion images; (b) the percentage of diseased segments was increased by 7.2 % when perfusion imaging was compared to the detailed reading of diagnostic images, and by 26.6 % when compared to the standard reading of images. At a patient level, the extent of peripheral CPE was higher on perfusion imaging, with a greater impact when compared to the standard reading of diagnostic images (number of patients with a greater number of diseased segments: n = 45; 72.6 % of the study population). Perfusion imaging allows recognition of a greater extent of peripheral CPE compared to diagnostic imaging. • Dual-energy computed tomography generates standard diagnostic imaging and lung perfusion analysis. • Depiction of CPE on central arteries relies on standard diagnostic imaging. • Detection of peripheral CPE is improved by perfusion imaging.
Grosser, Oliver S.; Kupitz, Dennis; Ruf, Juri; Czuczwara, Damian; Steffen, Ingo G.; Furth, Christian; Thormann, Markus; Loewenthal, David; Ricke, Jens; Amthauer, Holger
2015-01-01
Background Hybrid imaging combines nuclear medicine imaging such as single photon emission computed tomography (SPECT) or positron emission tomography (PET) with computed tomography (CT). Through this hybrid design, scanned patients accumulate radiation exposure from both applications. Imaging modalities have been the subject of long-term optimization efforts, focusing on diagnostic applications. It was the aim of this study to investigate the influence of an iterative CT image reconstruction algorithm (ASIR) on the image quality of the low-dose CT images. Methodology/Principal Findings Examinations were performed with a SPECT-CT scanner with standardized CT and SPECT-phantom geometries and CT protocols with systematically reduced X-ray tube currents. Analyses included image quality with respect to photon flux. Results were compared to the standard FBP reconstructed images. The general impact of the CT-based attenuation maps used during SPECT reconstruction was examined for two SPECT phantoms. Using ASIR for image reconstructions, image noise was reduced compared to FBP reconstructions for the same X-ray tube current. The Hounsfield unit (HU) values reconstructed by ASIR were correlated to the FBP HU values(R2 ≥ 0.88) and the contrast-to-noise ratio (CNR) was improved by ASIR. However, for a phantom with increased attenuation, the HU values shifted for low X-ray tube currents I ≤ 60 mA (p ≤ 0.04). In addition, the shift of the HU values was observed within the attenuation corrected SPECT images for very low X-ray tube currents (I ≤ 20 mA, p ≤ 0.001). Conclusion/Significance In general, the decrease in X-ray tube current up to 30 mA in combination with ASIR led to a reduction of CT-related radiation exposure without a significant decrease in image quality. PMID:26390216
Scientist-Image Stereotypes: The Relationships among Their Indicators
ERIC Educational Resources Information Center
Karaçam, Sedat
2016-01-01
The aim of this study is to examine primary school students' scientist-image stereotypes by considering the relationships among indicators. A total of 877 students attending Grades 6 and 7 in Düzce, Turkey participated in this study. The Draw-A-Scientist Test (DAST) was implemented during the 2013-2014 academic year to determine students' images…
ERIC Educational Resources Information Center
Andrew, Rachel; Tiggemann, Marika; Clark, Levina
2016-01-01
This study aimed to investigate prospective predictors and health-related outcomes of positive body image in adolescent girls. In so doing, the modified acceptance model of intuitive eating was also examined longitudinally. A sample of 298 girls aged 12 to 16 years completed a questionnaire containing measures of body appreciation, potential…
Imag(in)ing the University: Visual Sociology and Higher Education
ERIC Educational Resources Information Center
Metcalfe, Amy Scott
2012-01-01
This study examines the potential of visual sociology to expand our knowledge of higher education through the use of visual data sources and methods of analysis. Photographs and archival material form the basis of the study. The images were analyzed as being part of the initiation and fulfillment stages of the social construction of collective…
Mulgrew, K E; Volcevski-Kostas, D
2012-09-01
Viewing idealized images has been shown to reduce men's body satisfaction; however no research has examined the impact of music video clips. This was the first study to examine the effects of exposure to muscular images in music clips on men's body image, mood and cognitions. Ninety men viewed 5 min of clips containing scenery, muscular or average-looking singers, and completed pre- and posttest measures of mood and body image. Appearance schema activation was also measured. Men exposed to the muscular clips showed poorer posttest levels of anger, body and muscle tone satisfaction compared to men exposed to the scenery or average clips. No evidence of schema activation was found, although potential problems with the measure are noted. These preliminary findings suggest that even short term exposure to music clips can produce negative effects on men's body image and mood. Copyright © 2012 Elsevier Ltd. All rights reserved.
Automated detection of changes in sequential color ocular fundus images
NASA Astrophysics Data System (ADS)
Sakuma, Satoshi; Nakanishi, Tadashi; Takahashi, Yasuko; Fujino, Yuichi; Tsubouchi, Tetsuro; Nakanishi, Norimasa
1998-06-01
A recent trend is the automatic screening of color ocular fundus images. The examination of such images is used in the early detection of several adult diseases such as hypertension and diabetes. Since this type of examination is easier than CT, costs less, and has no harmful side effects, it will become a routine medical examination. Normal ocular fundus images are found in more than 90% of all people. To deal with the increasing number of such images, this paper proposes a new approach to process them automatically and accurately. Our approach, based on individual comparison, identifies changes in sequential images: a previously diagnosed normal reference image is compared to a non- diagnosed image.
Hultenmo, Maria; Caisander, Håkan; Mack, Karsten; Thilander-Klang, Anne
2016-06-01
The diagnostic image quality of 75 paediatric abdominal computed tomography (CT) examinations reconstructed with two different iterative reconstruction (IR) algorithms-adaptive statistical IR (ASiR™) and model-based IR (Veo™)-was compared. Axial and coronal images were reconstructed with 70 % ASiR with the Soft™ convolution kernel and with the Veo algorithm. The thickness of the reconstructed images was 2.5 or 5 mm depending on the scanning protocol used. Four radiologists graded the delineation of six abdominal structures and the diagnostic usefulness of the image quality. The Veo reconstruction significantly improved the visibility of most of the structures compared with ASiR in all subgroups of images. For coronal images, the Veo reconstruction resulted in significantly improved ratings of the diagnostic use of the image quality compared with the ASiR reconstruction. This was not seen for the axial images. The greatest improvement using Veo reconstruction was observed for the 2.5 mm coronal slices. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Cardiovascular Imaging and Image Processing: Theory and Practice - 1975
NASA Technical Reports Server (NTRS)
Harrison, Donald C. (Editor); Sandler, Harold (Editor); Miller, Harry A. (Editor); Hood, Manley J. (Editor); Purser, Paul E. (Editor); Schmidt, Gene (Editor)
1975-01-01
Ultrasonography was examined in regard to the developmental highlights and present applicatons of cardiac ultrasound. Doppler ultrasonic techniques and the technology of miniature acoustic element arrays were reported. X-ray angiography was discussed with special considerations on quantitative three dimensional dynamic imaging of structure and function of the cardiopulmonary and circulatory systems in all regions of the body. Nuclear cardiography and scintigraphy, three--dimensional imaging of the myocardium with isotopes, and the commercialization of the echocardioscope were studied.
NASA Astrophysics Data System (ADS)
Grubbs, Guy; Michell, Robert; Samara, Marilia; Hampton, Donald; Hecht, James; Solomon, Stanley; Jahn, Jorg-Micha
2018-01-01
It is important to routinely examine and update models used to predict auroral emissions resulting from precipitating electrons in Earth's magnetotail. These models are commonly used to invert spectral auroral ground-based images to infer characteristics about incident electron populations when in situ measurements are unavailable. In this work, we examine and compare auroral emission intensities predicted by three commonly used electron transport models using varying electron population characteristics. We then compare model predictions to same-volume in situ electron measurements and ground-based imaging to qualitatively examine modeling prediction error. Initial comparisons showed differences in predictions by the GLobal airglOW (GLOW) model and the other transport models examined. Chemical reaction rates and radiative rates in GLOW were updated using recent publications, and predictions showed better agreement with the other models and the same-volume data, stressing that these rates are important to consider when modeling auroral processes. Predictions by each model exhibit similar behavior for varying atmospheric constants, energies, and energy fluxes. Same-volume electron data and images are highly correlated with predictions by each model, showing that these models can be used to accurately derive electron characteristics and ionospheric parameters based solely on multispectral optical imaging data.
Investigation of ultra low-dose scans in the context of quantum-counting clinical CT
NASA Astrophysics Data System (ADS)
Weidinger, T.; Buzug, T. M.; Flohr, T.; Fung, G. S. K.; Kappler, S.; Stierstorfer, K.; Tsui, B. M. W.
2012-03-01
In clinical computed tomography (CT), images from patient examinations taken with conventional scanners exhibit noise characteristics governed by electronics noise, when scanning strongly attenuating obese patients or with an ultra-low X-ray dose. Unlike CT systems based on energy integrating detectors, a system with a quantum counting detector does not suffer from this drawback. Instead, the noise from the electronics mainly affects the spectral resolution of these detectors. Therefore, it does not contribute to the image noise in spectrally non-resolved CT images. This promises improved image quality due to image noise reduction in scans obtained from clinical CT examinations with lowest X-ray tube currents or obese patients. To quantify the benefits of quantum counting detectors in clinical CT we have carried out an extensive simulation study of the complete scanning and reconstruction process for both kinds of detectors. The simulation chain encompasses modeling of the X-ray source, beam attenuation in the patient, and calculation of the detector response. Moreover, in each case the subsequent image preprocessing and reconstruction is modeled as well. The simulation-based, theoretical evaluation is validated by experiments with a novel prototype quantum counting system and a Siemens Definition Flash scanner with a conventional energy integrating CT detector. We demonstrate and quantify the improvement from image noise reduction achievable with quantum counting techniques in CT examinations with ultra-low X-ray dose and strong attenuation.
Characterizing the behavior of scattered radiation in multi-energy x-ray imaging
NASA Astrophysics Data System (ADS)
Sossin, Artur; Rebuffel, V.; Tabary, J.; Létang, J. M.; Freud, N.; Verger, L.
2017-04-01
Scattered radiation results in various undesirable effects in medical diagnostics, non-destructive testing (NDT) and security x-ray imaging. Despite numerous studies characterizing this phenomenon and its effects, the knowledge of its behavior in the energy domain remains limited. The present study aims at summarizing some key insights on scattered radiation originating from the inspected object. In addition, various simulations and experiments with limited collimation on both simplified and realistic phantoms were conducted in order to study scatter behavior in multi-energy x-ray imaging. Results showed that the spectrum shape of the scatter component can be considered preserved in the first approximation across the image plane for various acquisition geometries and phantoms. The variations exhibited by the scatter spectrum were below 10% for most examined cases. Furthermore, the corresponding spectrum shape proved to be also relatively invariant for different experimental angular projections of one of the examined phantoms. The observed property of scattered radiation can potentially lead to the decoupling of spatial and energy scatter components, which can in turn enable speed ups in scatter simulations and reduce the complexity of scatter correction.
NASA Astrophysics Data System (ADS)
Anai, T.; Kochi, N.; Yamada, M.; Sasaki, T.; Otani, H.; Sasaki, D.; Nishimura, S.; Kimoto, K.; Yasui, N.
2015-05-01
As the 3D image measurement software is now widely used with the recent development of computer-vision technology, the 3D measurement from the image is now has acquired the application field from desktop objects as wide as the topography survey in large geographical areas. Especially, the orientation, which used to be a complicated process in the heretofore image measurement, can be now performed automatically by simply taking many pictures around the object. And in the case of fully textured object, the 3D measurement of surface features is now done all automatically from the orientated images, and greatly facilitated the acquisition of the dense 3D point cloud from images with high precision. With all this development in the background, in the case of small and the middle size objects, we are now furnishing the all-around 3D measurement by a single digital camera sold on the market. And we have also developed the technology of the topographical measurement with the air-borne images taken by a small UAV [1~5]. In this present study, in the case of the small size objects, we examine the accuracy of surface measurement (Matching) by the data of the experiments. And as to the topographic measurement, we examine the influence of GCP distribution on the accuracy by the data of the experiments. Besides, we examined the difference of the analytical results in each of the 3D image measurement software. This document reviews the processing flow of orientation and the 3D measurement of each software and explains the feature of the each software. And as to the verification of the precision of stereo-matching, we measured the test plane and the test sphere of the known form and assessed the result. As to the topography measurement, we used the air-borne image data photographed at the test field in Yadorigi of Matsuda City, Kanagawa Prefecture JAPAN. We have constructed Ground Control Point which measured by RTK-GPS and Total Station. And we show the results of analysis made in each of the 3D image measurement software. Further, we deepen the study on the influence of the distribution of GCP on the precision.
Cardiac phase detection in intravascular ultrasound images
NASA Astrophysics Data System (ADS)
Matsumoto, Monica M. S.; Lemos, Pedro Alves; Yoneyama, Takashi; Furuie, Sergio Shiguemi
2008-03-01
Image gating is related to image modalities that involve quasi-periodic moving organs. Therefore, during intravascular ultrasound (IVUS) examination, there is cardiac movement interference. In this paper, we aim to obtain IVUS gated images based on the images themselves. This would allow the reconstruction of 3D coronaries with temporal accuracy for any cardiac phase, which is an advantage over the ECG-gated acquisition that shows a single one. It is also important for retrospective studies, as in existing IVUS databases there are no additional reference signals (ECG). From the images, we calculated signals based on average intensity (AI), and, from consecutive frames, average intensity difference (AID), cross-correlation coefficient (CC) and mutual information (MI). The process includes a wavelet-based filter step and ascendant zero-cross detection in order to obtain the phase information. Firstly, we tested 90 simulated sequences with 1025 frames each. Our method was able to achieve more than 95.0% of true positives and less than 2.3% of false positives ratio, for all signals. Afterwards, we tested in a real examination, with 897 frames and ECG as gold-standard. We achieved 97.4% of true positives (CC and MI), and 2.5% of false positives. For future works, methodology should be tested in wider range of IVUS examinations.
Conners, Amy Lynn; Jones, Katie N; Hruska, Carrie B; Geske, Jennifer R; Boughey, Judy C; Rhodes, Deborah J
2015-09-01
The purposes of this study were to compare the tumor appearance of invasive breast cancer on direct-conversion molecular breast imaging using a standardized lexicon and to determine how often direct-conversion molecular breast imaging identifies all known invasive tumor foci in the breast, and whether this differs for invasive ductal versus lobular histologic profiles. Patients with prior invasive breast cancer and concurrent direct-conversion molecular breast imaging examinations were retrospectively reviewed. Blinded review of direct-conversion molecular breast imaging examinations was performed by one of two radiologists, according to a validated lexicon. Direct-conversion molecular breast imaging findings were matched with lesions described on the pathology report to exclude benign reasons for direct-conversion molecular breast imaging findings and to document direct-conversion molecular breast imaging-occult tumor foci. Associations between direct-conversion molecular breast imaging findings and tumor histologic profiles were examined using chi-square tests. In 286 patients, 390 invasive tumor foci were present in 294 breasts. A corresponding direct-conversion molecular breast imaging finding was present for 341 of 390 (87%) tumor foci described on the pathology report. Invasive ductal carcinoma (IDC) tumor foci were more likely to be a mass (40% IDC vs 15% invasive lobular carcinoma [ILC]; p < 0.001) and to have marked intensity than were ILC foci (63% IDC vs 32% ILC; p < 0.001). Direct-conversion molecular breast imaging correctly revealed all pathology-proven foci of invasive disease in 79.8% of cases and was more likely to do so for IDC than for ILC (86.1% vs 56.7%; p < 0.0001). Overall, direct-conversion molecular breast imaging showed all known invasive foci in 249 of 286 (87%) patients. Direct-conversion molecular breast imaging features of invasive cancer, including lesion type and intensity, differ by histologic subtype. Direct-conversion molecular breast imaging is less likely to show all foci of ILC compared with IDC.
Adipose Tissue Quantification by Imaging Methods: A Proposed Classification
Shen, Wei; Wang, ZiMian; Punyanita, Mark; Lei, Jianbo; Sinav, Ahmet; Kral, John G.; Imielinska, Celina; Ross, Robert; Heymsfield, Steven B.
2007-01-01
Recent advances in imaging techniques and understanding of differences in the molecular biology of adipose tissue has rendered classical anatomy obsolete, requiring a new classification of the topography of adipose tissue. Adipose tissue is one of the largest body compartments, yet a classification that defines specific adipose tissue depots based on their anatomic location and related functions is lacking. The absence of an accepted taxonomy poses problems for investigators studying adipose tissue topography and its functional correlates. The aim of this review was to critically examine the literature on imaging of whole body and regional adipose tissue and to create the first systematic classification of adipose tissue topography. Adipose tissue terminology was examined in over 100 original publications. Our analysis revealed inconsistencies in the use of specific definitions, especially for the compartment termed “visceral” adipose tissue. This analysis leads us to propose an updated classification of total body and regional adipose tissue, providing a well-defined basis for correlating imaging studies of specific adipose tissue depots with molecular processes. PMID:12529479
Boniface, Keith S; Shokoohi, Hamid; Smith, E Reed; Scantlebury, Kari
2011-06-01
The aim of this study was to examine the capability of ultrasound-naïve paramedics to obtain interpretable Focused Assessment With Sonography for Trauma (FAST) images under the remote direction of emergency physicians (EPs). Paramedics without experience using ultrasound participated in a 20-minute lecture covering orientation to the ultrasound machine and the FAST examination. The paramedics subsequently performed FAST examinations on a model patient, whereas the EP remained in another room, out of visual contact. The EP communicated with the paramedic via radio, viewing video from the ultrasound machine on a monitor and directing the probe movements to obtain the views of the FAST examination. We examined the success rate, time to complete the examinations, and adequacy of images from the paramedics' first FAST examination. Fifty-one paramedics performed their first FAST examinations and were able to successfully complete 100% of the views of the FAST. The median time from probe placement to examination completion was 262 seconds (interquartile range, 206-343 seconds). The median time to complete right upper quadrant (RUQ) versus left upper quadrant (LUQ) views was 39 and 50 seconds, respectively. The time to complete the LUQ scan took significantly longer than the RUQ (P < .01). Paramedics completed cardiac and pelvic view in a median time of 42 and 25 seconds, respectively. The study demonstrated that paramedics with no prior ultrasound experience could obtain FAST images under remote guidance from experienced EPs in less than 5 minutes. Given rapidly evolving data transmission technology, this has applicability in battlefield, remote, and rural prehospital settings. Copyright © 2011 Elsevier Inc. All rights reserved.
Dedecjus, Marek; Adamczewski, Zbigniew; Brzeziński, Jan; Lewiński, Andrzej
2010-09-01
The aim of the study was to evaluate the functionality of vocal folds (VF) by real-time, high-resolution ultrasonography (US) and to correlate the imaged features to results of laryngological examination (LE). The study group comprised 50 patients (41 females and nine males), qualified to thyroidectomy. All the patients had LE and US examination before and 2 days, 2 months, and 3 months after the surgery. We used high-resolution US imaging to identify VFs and, subsequently, a pulsed Doppler and Doppler gate to quantify the tissue displacement velocity in the vibrating VF section. LE revealed unilateral VF paralysis in two patients. VF dysfunction was diagnosed in other four subjects. In simultaneously performed US examination, changes in VF displacement velocity (VFDV) were observed in ten patients. In two subjects, VFDV was below 30 cm/s- patients with VF paralysis, diagnosed in LE. In a further eight cases, we observed VFDV decrease by 50%, comparing to preoperative values. Both US-imaging and LE, performed after the 3-month follow-up, confirmed the transitional character of the above-mentioned pathologies. US imaging of the VFs correlated with LE results, while being a minimally invasive, easily reproducible, and inexpensive method of examining VF functionality. Thanks to many recording options, it may soon become a perfect tool for an early identification of postoperative VF dysfunction with its later monitoring. To our knowledge, it is the first application of US and Doppler gate modes for VFDF quantification; however, an analysis on a larger group of patients is necessary to standardize the technique.
Ringkamp, Matthias; Wooten, Matthew; Carson, Benjamin S; Lim, Michael; Hartke, Timothy; Guarnieri, Michael
2016-02-01
Percutaneous treatments for trigeminal neuralgia are safe, simple, and effective for achieving good pain control. Procedural risks could be minimized by using noninvasive imaging techniques to improve the placement of the radiofrequency thermocoagulation probe into the trigeminal ganglion. Positioning of a probe is crucial to maximize pain relief and to minimize unwanted side effects, such as denervation in unaffected areas. This investigation examined the use of laser speckle imaging during probe placement in an animal model. This preclinical safety study used nonhuman primates, Macaca nemestrina (pigtail monkeys), to examine whether real-time imaging of blood flow in the face during the positioning of a coagulation probe could monitor the location and guide the positioning of the probe within the trigeminal ganglion. Data from 6 experiments in 3 pigtail monkeys support the hypothesis that laser imaging is safe and improves the accuracy of probe placement. Noninvasive laser speckle imaging can be performed safely in nonhuman primates. Because improved probe placement may reduce morbidity associated with percutaneous rhizotomies, efficacy trials of laser speckle imaging should be conducted in humans.
MR pyelography and conventional MR imaging in urinary tract obstruction.
Catalano, C; Pavone, P; Laghi, A; Scipioni, A; Panebianco, V; Brillo, R; Fraioli, F; Passariello, R
1999-03-01
To evaluate the possible role of MR imaging in the assessment of patients with urinary tract obstruction by combining conventional MR imaging and MR pyelography (MRP). Forty-three patients with dilated upper urinary tract were studied with a high gradient strength 0.5 T magnet. Respiratory compensated T1-weighted, SE and T2-weighted TSE sequences were acquired in all patients. MRP images were obtained by using a respiratory compensated 3D T2-weighted TSE sequence. MRP images were reconstructed with a MIP algorithm. In all cases, urography and/or ascending pyelography were also performed. Images were independently evaluated by two radiologists. The dilated tract ureter and the level of the obstruction could be correctly demonstrated in all cases. The cause of the obstruction was correctly demonstrated by examiner 1 in 90% and by examiner 2 in 88%. The interobserver agreement was high with a kappa-value of 0.96. In cases of obstructive hydroureteronephrosis MR imaging, combining MRP and conventional sequences, can be proposed as an accurate technique in the assessment of level and cause of obstruction.
Benson, John C.; Idiyatullin, Djaudat; Snyder, Angela L.; Snyder, Carl J.; Hutter, Diane; Everson, Lenore I.; Eberly, Lynn E.; Nelson, Michael T.; Garwood, Michael
2015-01-01
Purpose To report the results of sweep imaging with Fourier transformation (SWIFT) magnetic resonance (MR) imaging for diagnostic breast imaging. Materials and Methods Informed consent was obtained from all participants under one of two institutional review board–approved, HIPAA-compliant protocols. Twelve female patients (age range, 19–54 years; mean age, 41.2 years) and eight normal control subjects (age range, 22–56 years; mean age, 43.2 years) enrolled and completed the study from January 28, 2011, to March 5, 2013. Patients had previous lesions that were Breast Imaging Reporting and Data System 4 and 5 based on mammography and/or ultrasonographic imaging. Contrast-enhanced SWIFT imaging was completed by using a 4-T research MR imaging system. Noncontrast studies were completed in the normal control subjects. One of two sized single-breast SWIFT-compatible transceiver coils was used for nine patients and five controls. Three patients and five control subjects used a SWIFT-compatible dual breast coil. Temporal resolution was 5.9–7.5 seconds. Spatial resolution was 1.00 mm isotropic, with later examinations at 0.67 mm isotropic, and dual breast at 1.00 mm or 0.75 mm isotropic resolution. Results Two nonblinded breast radiologists reported SWIFT image findings of normal breast tissue, benign fibroadenomas (six of six lesions), and malignant lesions (10 of 12 lesions) concordant with other imaging modalities and pathologic reports. Two lesions in two patients were not visualized because of coil field of view. The images yielded by SWIFT showed the presence and extent of known breast lesions. Conclusion The SWIFT technique could become an important addition to breast imaging modalities because it provides high spatial resolution at all points during the dynamic contrast-enhanced examination. © RSNA, 2014 PMID:25247405
Self-image and ethnic identification in South Africa.
Bornman, E
1999-08-01
This study examined the relationship between self-image and ethnic identification among 3 South African groups. Participants included random samples of 347 Afrikaans-speaking Whites, 113 English-speaking Whites, and 466 Blacks in urban Gauteng. Positive and negative self-image were extracted using the Rosenberg Self-Esteem Scale (M. Rosenberg, 1965). Afrikaans-speaking Whites had the most positive self-image and Blacks the most negative self-image. A positive self-image was correlated with stronger ethnic identification among Afrikaans-speaking Whites. The opposite was true for Blacks. This relationship was insignificant among English-speaking Whites. Ambivalence toward ingroup identity was persistently correlated with self-image for all groups.
Kim, Michael E; Orth, Robert C; Fallon, Sara C; Lopez, Monica E; Brandt, Mary L; Zhang, Wei; Bisset, George S
2015-04-01
Despite a recent focus on the preferential use of ultrasound over CT for pediatric appendicitis, most children transferred from community hospitals still undergo diagnostic CT scans. The purpose of this study was to evaluate CT techniques performed for children with acute appendicitis at nonpediatric treatment centers. All patients treated for acute appendicitis at our tertiary-care pediatric hospital from July 1, 2011, through June 30, 2012, were identified. Patient demographics, imaging modality used to diagnoses appendicitis (CT or ultrasound), location (home or referral institution), and CT technique parameters were collected. The estimated mean organ radiation dose, number of imaging phases, and use of contrast media were evaluated at home and referral institutions. During the study period, 1215 patients underwent appendectomies after imaging, with 442 (36.4%) imaged at referral facilities. Most referral patients received a diagnosis by CT (n=384, 87%), compared with 73 of 773 (9.4%) who received a diagnosis by CT at the home institution. The estimated mean (±SD) organ radiation dose was not statistically significantly different between home and referral institutions (13.5±7.3 vs 12.9±6.4 mGy; p=0.58) for single-phase examinations. Of 384 referral patients, 344 had images available for review. In total, 40% (138/344) of patients from referral centers were imaged with suboptimal CT techniques: 50 delayed phase only, 52 dual phase (eight of which were imaged twice in delayed phase), eight triple phase, and 36 without IV contrast agent. CT parameters and radiation doses from single-phase examinations in children with appendicitis were similar at nonpediatric treatment centers and a tertiary care children's hospital. Future educational outreach should focus on optimizing other technical parameters.
Kollara, Lakshmi; Schenck, Graham; Jaskolka, Michael; Perry, Jamie L
2017-04-14
To date, no studies have imaged the velopharynx in children with 22q11.2 deletion syndrome (22q11.2 DS) without the use of sedation. Dysmorphology in velopharyngeal structures has been shown to have significant negative implications on speech among these individuals. This single case study was designed to assess the feasibility of a child-friendly magnetic resonance imaging (MRI) scanning protocol in this clinically challenging population and to determine the utility of this MRI protocol for future work in this area. One 6-year-old White girl diagnosed with 22q11.2 DS was imaged using a child-friendly, nonsedated MRI protocol. Quantitative and qualitative measures of the velopharyngeal area and associated structures were evaluated, and comparisons were made to age-matched control subjects with normal velopharyngeal anatomy. MRI data were successfully obtained using the child-friendly scanning protocol in the subject in the present study. Quantitative and qualitative differences of the levator muscle and associated velopharyngeal structures were noted. Using these MRI and structural analyses methods, insights related to muscle morphology can be obtained and considered as part of the research and clinical examination of children with 22q11.2 DS. The imaging protocol described in this study presents an effective means to counteract difficulties in imaging young children.
Lumbar disc herniation in young children.
Haidar, R; Ghanem, I; Saad, S; Uthman, I
2010-01-01
This article explores lumbar disc herniation in young children through focusing on matters relevant to patient presentation, physical examination, differential diagnosis, imaging and treatment. Major databases were searched for studies that addressed lumbar disc herniation in young children. Diagnosis of lumbar disc herniation in young children is usually delayed because of the rarity and lack of experience with this entity and the difficulty in extracting a reliable medical history. Nevertheless, lumbar disc herniation should be considered in the differential diagnosis of any young child presenting with a chief complaint of back pain and/or radiculopathy, especially in the setting of recent trauma. This should be coupled with a directed physical examination to elicit signs and narrow the differential diagnosis. Imaging studies, mainly magnetic resonance imaging, will help establish a diagnosis; yet radiographs are still required to exclude other spinal lesions. The initial management of lumbar disc herniation in children is the same as that in adults and consists of conservative treatment unless lumbar disc herniation affects the patient's motor and neurological functions in which case, early surgical treatment must be undertaken. Although the latter remains more difficult, current experience suggests a favourable outcome. Awareness of lumbar disc herniation will help the paediatrician extract a relevant medical history, perform a directed physical examination, and order appropriate imaging studies. This will aid in initiating early intervention, be it conservative or operative, and achieving a favourable outcome.
Kuo, Chung-Feng Jeffrey; Chu, Yueng-Hsiang; Wang, Po-Chun; Lai, Chun-Yu; Chu, Wen-Lin; Leu, Yi-Shing; Wang, Hsing-Won
2013-12-01
The human larynx is an important organ for voice production and respiratory mechanisms. The vocal cord is approximated for voice production and open for breathing. The videolaryngoscope is widely used for vocal cord examination. At present, physicians usually diagnose vocal cord diseases by manually selecting the image of the vocal cord opening to the largest extent (abduction), thus maximally exposing the vocal cord lesion. On the other hand, the severity of diseases such as vocal palsy, atrophic vocal cord is largely dependent on the vocal cord closing to the smallest extent (adduction). Therefore, diseases can be assessed by the image of the vocal cord opening to the largest extent, and the seriousness of breathy voice is closely correlated to the gap between vocal cords when closing to the smallest extent. The aim of the study was to design an automatic vocal cord image selection system to improve the conventional selection process by physicians and enhance diagnosis efficiency. Also, due to the unwanted fuzzy images resulting from examination process caused by human factors as well as the non-vocal cord images, texture analysis is added in this study to measure image entropy to establish a screening and elimination system to effectively enhance the accuracy of selecting the image of the vocal cord closing to the smallest extent. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Imaging in the newborn: infant immobilizer obviates the need for anesthesia.
Golan, Agneta; Marco, Rina; Raz, Hagit; Shany, Eilon
2011-11-01
Neonatal cerebral imaging is a sensitive technique for evaluating brain injury in the neonatal period. When performing computed tomography or magnetic resonance imaging, sedation is needed to prevent motion artifacts. However, general anesthesia in neonates carries significant risks and requires a complex logistic approach that often limits the use of these modalities. The development of infant immobilizers now enables imaging without general anesthesia and significantly increases clinical and research investigational opportunities. To assess the efficacy of the infant immobilizer instead of general anesthesia for infants undergoing imaging. The study group comprised all infants born over a 1 year period at Soroka University Medical Center who required imaging such as MRI, CT or bone scans. A MedVac Vacuum Splint infant immobilizer was used in all infants to prevent motion during imaging. The success rate of a single scan and the need for general anesthesia were assessed. Forty infants were examined during 1 year. The studies included 15 CT scans, 25 MRIs and 1 bone scan. The infants' gestational age at birth was 27-40 weeks and the examinations were performed at ages ranging from delivery to 6 months old. All imaging was successful and none of the infants required general anesthesia. An infant immobilizer should be used for imaging of newborns. Since this method carries a low risk and has a high success rate, general anesthesia in newborns is justified only when this non-invasive procedure fails.
Kirdar, YalçIn
2007-01-01
This study discusses the role of public relations for image creating in health services. Hospitals require public relations activities to distinguish them from competitors, provide bidirectional communication between the society and the hospital, and assist to create of a strong hospital image and culture. A satisfaction survey was conducted on 264 patients who have received health services at Maltepe University Hospital. The research focused on how the Hospital's examination, care, catering and physical services; doctor and nurse politeness towards patients and patient relatives, their attitudes and behaviors; examination, check-in, bedding and discharge operations; public relations activities in and out of the hospital were perceived. Another subject of the study was the degree of recommendation of patients who have been served by the hospital's health services to prospective patients seeking treatment.
An evaluation of the impact of digital imaging on radiographic practice and patient doses
NASA Astrophysics Data System (ADS)
Horrocks, J.; Violaki, K.
2015-09-01
Direct digital imaging technology was implemented in all areas in general and mobile radiology at Barts and the Royal London Hospitals in 2012. Evidence from recent radiation incident investigations indicates optimum exposure factors are not consistently selected, with the greater dynamic range of the digital detectors allowing sub-optimal practice. To investigate further patient dose data were extracted from the Radiology Information System for adult chest X-ray examinations in 2014, covering over 50,000 studies in the Trust. Chest X-ray examinations were selected as they are low dose but frequent examinations. The patient dose data were evaluated taking into account X-ray system type and detector performance measurements, and individual cases studies were used to highlight where practice can be improved.
Derkacz, Arkadiusz; Gawrys, Jakub; Gawrys, Karolina; Podgorski, Maciej; Magott-Derkacz, Agnieszka; Poreba, Rafał; Doroszko, Adrian
2018-06-01
The effect of electromagnetic field on cardiovascular system in the literature is defined in ambiguous way. The aim of this study was to evaluate the effect of electromagnetic field on the heart rate variability (HRV) during the examination with magnetic resonance. Forty-two patients underwent Holter ECG heart monitoring for 30 minutes twice: immediately before and after the examination with magnetic resonance imaging (MRI). HRV was analysed by assessing a few selected time and spectral parameters. Is has been shown that standard deviation of NN intervals (SDNN) and very low frequency rates increased, whereas the low frequency:high frequency parameter significantly decreased following the MRI examination. These results show that MRI may affect the HRV most likely by changing the sympathetic-parasympathetic balance.
Malghem, Jacques; Lecouvet, Frédéric E; François, Robert; Vande Berg, Bruno C; Duprez, Thierry; Cosnard, Guy; Maldague, Baudouin E
2005-02-01
To explain a cause of high signal intensity on T1-weighted MR images in calcified intervertebral disks associated with spinal fusion. Magnetic resonance and radiological examinations of 13 patients were reviewed, presenting one or several intervertebral disks showing a high signal intensity on T1-weighted MR images, associated both with the presence of calcifications in the disks and with peripheral fusion of the corresponding spinal segments. Fusion was due to ligament ossifications (n=8), ankylosing spondylitis (n=4), or posterior arthrodesis (n=1). Imaging files included X-rays and T1-weighted MR images in all cases, T2-weighted MR images in 12 cases, MR images with fat signal suppression in 7 cases, and a CT scan in 1 case. Histological study of a calcified disk from an anatomical specimen of an ankylosed lumbar spine resulting from ankylosing spondylitis was examined. The signal intensity of the disks was similar to that of the bone marrow or of perivertebral fat both on T1-weighted MR images and on all sequences, including those with fat signal suppression. In one of these disks, a strongly negative absorption coefficient was focally measured by CT scan, suggesting a fatty content. The histological examination of the ankylosed calcified disk revealed the presence of well-differentiated bone tissue and fatty marrow within the disk. The high signal intensity of some calcified intervertebral disks on T1-weighted MR images can result from the presence of fatty marrow, probably related to a disk ossification process in ankylosed spines.
Myositis Ossificans Mimicking Sarcoma, the Importance of Diagnostic Imaging – Case Report
Łuczyńska, Elżbieta; Kasperkiewicz, Hanna; Domalik, Agnieszka; Cwierz, Anna; Bobek-Billewicz, Barbara
2014-01-01
Summary Background Myositis ossificans is localized inflammatory process affecting skeletal muscles. Very rarely it can affect one of the neck muscles and present as a neck tumor, it can be misdiagnosed as the clinical, radiological and histological examinations can mimic a sarcoma. Case Report We report a 29 year old female patient with neck tumor suspected to be a sarcoma who underwent full diagnostics imaging and open bipsy with histopatological examination, afterwards surgical excision was performed. Conclusions The aim of this study was to present the differential diagnosis based on diagnostics imaging between MO and malignant tumors, such as parosteal sarcoma, synovial sarcoma and malignant fibrous histiocytoma. PMID:25077008
Evaluation of the added value of imaging the pelvis in patients with hepatocellular cancer.
Szklaruk, Janio; Kaya, Diana; Wei, Wei
2018-02-01
The study aims to evaluate added value of the pelvic portion of the computed tomography (CT) and magnetic resonance imaging (MRI) examination in patients with a primary diagnosis of hepatocellular cancer (HCC). The study reviewed the medical records of 478 patients with 881 examinations of the abdomen and pelvis who underwent treatment at our institution between March 2015 and March 2016. These patients were reviewed for presence of pathology in the pelvis, which were classified into two categories as new or old (already known on prior imaging). Of 478 patients, 230 underwent MRI examination of the abdomen and pelvis, and the other 248 underwent CT scans of these regions. There were no findings on the CT or MRI of the pelvis in 80.5% of patients (n = 385), including 81.5% of those who had CT and 79.6% of those who had MRI. Ninety-three patients had findings in the pelvis, the most common of which were bone metastases (31 patients), ascites (27 patients), implants (seven patients), and bladder wall thickening (five patients). In only 7.9% of patients, the findings were related to metastatic disease. In 5.4% of all imaging studies revealed a new finding in the pelvis. Imaging of the pelvis (CT or MRI) does not seem to provide additional information in the majority of cases with HCC. The results suggest that the follow-up evaluation of patients with HCC may not include a pelvis exam. © 2017 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
Automated extraction of radiation dose information for CT examinations.
Cook, Tessa S; Zimmerman, Stefan; Maidment, Andrew D A; Kim, Woojin; Boonn, William W
2010-11-01
Exposure to radiation as a result of medical imaging is currently in the spotlight, receiving attention from Congress as well as the lay press. Although scanner manufacturers are moving toward including effective dose information in the Digital Imaging and Communications in Medicine headers of imaging studies, there is a vast repository of retrospective CT data at every imaging center that stores dose information in an image-based dose sheet. As such, it is difficult for imaging centers to participate in the ACR's Dose Index Registry. The authors have designed an automated extraction system to query their PACS archive and parse CT examinations to extract the dose information stored in each dose sheet. First, an open-source optical character recognition program processes each dose sheet and converts the information to American Standard Code for Information Interchange (ASCII) text. Each text file is parsed, and radiation dose information is extracted and stored in a database which can be queried using an existing pathology and radiology enterprise search tool. Using this automated extraction pipeline, it is possible to perform dose analysis on the >800,000 CT examinations in the PACS archive and generate dose reports for all of these patients. It is also possible to more effectively educate technologists, radiologists, and referring physicians about exposure to radiation from CT by generating report cards for interpreted and performed studies. The automated extraction pipeline enables compliance with the ACR's reporting guidelines and greater awareness of radiation dose to patients, thus resulting in improved patient care and management. Copyright © 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Cheng, Ye; Zhang, Siwen; Chen, Yong; Zhao, Gang
2015-01-01
Purpose Penetration of the clivus is required for surgical access of the brain stem. The endoscopic transclivus approach is a difficult procedure with high risk of injury to important neurovascular structures. We undertook a novel anatomical and radiological investigation to understand the structure of the clivus and neurovascular structures relevant to the extended trans-nasal trans-sphenoid procedure and determine a safe corridor for the penetration of the clivus. Method We examined the clivus region in the computed tomographic angiography (CTA) images of 220 adults, magnetic resonance (MR) images of 50 adults, and dry skull specimens of 10 adults. Multiplanar reconstruction (MPR) of the CT images was performed, and the anatomical features of the clivus were studied in the coronal, sagittal, and axial planes. The data from the images were used to determine the anatomical parameters of the clivus and neurovascular structures, such as the internal carotid artery and inferior petrosal sinus. Results The examination of the CTA and MR images of the enrolled subjects revealed that the thickness of the clivus helped determine the depth of the penetration, while the distance from the sagittal midline to the important neurovascular structures determined the width of the penetration. Further, data from the CTA and MR images were consistent with those retrieved from the examination of the cadaveric specimens. Conclusion Our findings provided certain pointers that may be useful in guiding the surgery such that inadvertent injury to vital structures is avoided and also provided supportive information for the choice of the appropriate endoscopic equipment. PMID:26368821
Komeda, Yoriaki; Handa, Hisashi; Watanabe, Tomohiro; Nomura, Takanobu; Kitahashi, Misaki; Sakurai, Toshiharu; Okamoto, Ayana; Minami, Tomohiro; Kono, Masashi; Arizumi, Tadaaki; Takenaka, Mamoru; Hagiwara, Satoru; Matsui, Shigenaga; Nishida, Naoshi; Kashida, Hiroshi; Kudo, Masatoshi
2017-01-01
Computer-aided diagnosis (CAD) is becoming a next-generation tool for the diagnosis of human disease. CAD for colon polyps has been suggested as a particularly useful tool for trainee colonoscopists, as the use of a CAD system avoids the complications associated with endoscopic resections. In addition to conventional CAD, a convolutional neural network (CNN) system utilizing artificial intelligence (AI) has been developing rapidly over the past 5 years. We attempted to generate a unique CNN-CAD system with an AI function that studied endoscopic images extracted from movies obtained with colonoscopes used in routine examinations. Here, we report our preliminary results of this novel CNN-CAD system for the diagnosis of colon polyps. A total of 1,200 images from cases of colonoscopy performed between January 2010 and December 2016 at Kindai University Hospital were used. These images were extracted from the video of actual endoscopic examinations. Additional video images from 10 cases of unlearned processes were retrospectively assessed in a pilot study. They were simply diagnosed as either an adenomatous or nonadenomatous polyp. The number of images used by AI to learn to distinguish adenomatous from nonadenomatous was 1,200:600. These images were extracted from the videos of actual endoscopic examinations. The size of each image was adjusted to 256 × 256 pixels. A 10-hold cross-validation was carried out. The accuracy of the 10-hold cross-validation is 0.751, where the accuracy is the ratio of the number of correct answers over the number of all the answers produced by the CNN. The decisions by the CNN were correct in 7 of 10 cases. A CNN-CAD system using routine colonoscopy might be useful for the rapid diagnosis of colorectal polyp classification. Further prospective studies in an in vivo setting are required to confirm the effectiveness of a CNN-CAD system in routine colonoscopy. © 2017 S. Karger AG, Basel.
Mueck, F G; Körner, M; Scherr, M K; Geyer, L L; Deak, Z; Linsenmaier, U; Reiser, M; Wirth, S
2012-03-01
To compare the image quality of dose-reduced 64-row abdominal CT reconstructed at different levels of adaptive statistical iterative reconstruction (ASIR) to full-dose baseline examinations reconstructed with filtered back-projection (FBP) in a clinical setting and upgrade situation. Abdominal baseline examinations (noise index NI = 29; LightSpeed VCT XT, GE) were intra-individually compared to follow-up studies on a CT with an ASIR option (NI = 43; Discovery HD750, GE), n = 42. Standard-kernel images were calculated with ASIR blendings of 0 - 100 % in slice and volume mode, respectively. Three experienced radiologists compared the image quality of these 567 sets to their corresponding full-dose baseline examination (- 2: diagnostically inferior, - 1: inferior, 0: equal, + 1: superior, + 2: diagnostically superior). Furthermore, a phantom was scanned. Statistical analysis used the Wilcoxon - the Mann-Whitney U-test and the intra-class correlation (ICC). The mean CTDIvol decreased from 19.7 ± 5.5 to 12.2 ± 4.7 mGy (p < 0.001). The ICC was 0.861. The total image quality of the dose-reduced ASIR studies was comparable to the baseline at ASIR 50 % in slice (p = 0.18) and ASIR 50 - 100 % in volume mode (p > 0.10). Volume mode performed 73 % slower than slice mode (p < 0.01). After the system upgrade, the vendor recommendation of ASIR 50 % in slice mode allowed for a dose reduction of 38 % in abdominal CT with comparable image quality and time expenditure. However, there is still further dose reduction potential for more complex reconstruction settings. © Georg Thieme Verlag KG Stuttgart · New York.
ERIC Educational Resources Information Center
Grabe, Shelly; Ward, L. Monique; Hyde, Janet Shibley
2008-01-01
Research suggests that exposure to mass media depicting the thin-ideal body may be linked to body image disturbance in women. This meta-analysis examined experimental and correlational studies testing the links between media exposure to women's body dissatisfaction, internalization of the thin ideal, and eating behaviors and beliefs with a sample…
Ryan, Michael C.; Ostmo, Susan; Jonas, Karyn; Berrocal, Audina; Drenser, Kimberly; Horowitz, Jason; Lee, Thomas C.; Simmons, Charles; Martinez-Castellanos, Maria-Ana; Chan, R.V. Paul; Chiang, Michael F.
2014-01-01
Information systems managing image-based data for telemedicine or clinical research applications require a reference standard representing the correct diagnosis. Accurate reference standards are difficult to establish because of imperfect agreement among physicians, and discrepancies between clinical vs. image-based diagnosis. This study is designed to describe the development and evaluation of reference standards for image-based diagnosis, which combine diagnostic impressions of multiple image readers with the actual clinical diagnoses. We show that agreement between image reading and clinical examinations was imperfect (689 [32%] discrepancies in 2148 image readings), as was inter-reader agreement (kappa 0.490-0.652). This was improved by establishing an image-based reference standard defined as the majority diagnosis given by three readers (13% discrepancies with image readers). It was further improved by establishing an overall reference standard that incorporated the clinical diagnosis (10% discrepancies with image readers). These principles of establishing reference standards may be applied to improve robustness of real-world systems supporting image-based diagnosis. PMID:25954463
Quality assessment of digital X-ray chest images using an anthropomorphic chest phantom
NASA Astrophysics Data System (ADS)
Vodovatov, A. V.; Kamishanskaya, I. G.; Drozdov, A. A.; Bernhardsson, C.
2017-02-01
The current study is focused on determining the optimal tube voltage for the conventional X-ray digital chest screening examinations, using a visual grading analysis method. Chest images of an anthropomorphic phantom were acquired in posterior-anterior projection on four digital X-ray units with different detector types. X-ray images obtained with an anthropomorphic phantom were accepted by the radiologists as corresponding to a normal human anatomy, hence allowing using phantoms in image quality trials without limitations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Damet, J., E-mail: jerome.damet@chuv.ch; Fournier, P.; Monnin, P.
Purpose: EOS (EOS imaging S.A, Paris, France) is an x-ray imaging system that uses slot-scanning technology in order to optimize the trade-off between image quality and dose. The goal of this study was to characterize the EOS system in terms of occupational exposure, organ doses to patients as well as image quality for full spine examinations. Methods: Occupational exposure was determined by measuring the ambient dose equivalents in the radiological room during a standard full spine examination. The patient dosimetry was performed using anthropomorphic phantoms representing an adolescent and a five-year-old child. The organ doses were measured with thermoluminescent detectorsmore » and then used to calculate effective doses. Patient exposure with EOS was then compared to dose levels reported for conventional radiological systems. Image quality was assessed in terms of spatial resolution and different noise contributions to evaluate the detector's performances of the system. The spatial-frequency signal transfer efficiency of the imaging system was quantified by the detective quantum efficiency (DQE). Results: The use of a protective apron when the medical staff or parents have to stand near to the cubicle in the radiological room is recommended. The estimated effective dose to patients undergoing a full spine examination with the EOS system was 290μSv for an adult and 200 μSv for a child. MTF and NPS are nonisotropic, with higher values in the scanning direction; they are in addition energy-dependent, but scanning speed independent. The system was shown to be quantum-limited, with a maximum DQE of 13%. The relevance of the DQE for slot-scanning system has been addressed. Conclusions: As a summary, the estimated effective dose was 290μSv for an adult; the image quality remains comparable to conventional systems.« less
Grabe, Shelly; Ward, L Monique; Hyde, Janet Shibley
2008-05-01
Research suggests that exposure to mass media depicting the thin-ideal body may be linked to body image disturbance in women. This meta-analysis examined experimental and correlational studies testing the links between media exposure to women's body dissatisfaction, internalization of the thin ideal, and eating behaviors and beliefs with a sample of 77 studies that yielded 141 effect sizes. The mean effect sizes were small to moderate (ds = -.28, -.39, and -.30, respectively). Effects for some outcome variables were moderated by publication year and study design. The findings support the notion that exposure to media images depicting the thin-ideal body is related to body image concerns for women. (Copyright) 2008 APA, all rights reserved.
Graessl, Andreas; Muhle, Maximilian; Schwerter, Michael; Rieger, Jan; Oezerdem, Celal; Santoro, Davide; Lysiak, Darius; Winter, Lukas; Hezel, Fabian; Waiczies, Sonia; Guthoff, Rudolf F; Falke, Karen; Hosten, Norbert; Hadlich, Stefan; Krueger, Paul-Christian; Langner, Soenke; Stachs, Oliver; Niendorf, Thoralf
2014-05-01
This study was designed to examine the feasibility of ophthalmic magnetic resonance imaging (MRI) at 7 T using a local 6-channel transmit/receive radiofrequency (RF) coil array in healthy volunteers and patients with intraocular masses. A novel 6-element transceiver RF coil array that makes uses of loop elements and that is customized for eye imaging at 7 T is proposed. Considerations influencing the RF coil design and the characteristics of the proposed RF coil array are presented. Numerical electromagnetic field simulations were conducted to enhance the RF coil characteristics. Specific absorption rate simulations and a thorough assessment of RF power deposition were performed to meet the safety requirements. Phantom experiments were carried out to validate the electromagnetic field simulations and to assess the real performance of the proposed transceiver array. Certified approval for clinical studies was provided by a local notified body before the in vivo studies. The suitability of the RF coil to image the human eye, optical nerve, and orbit was examined in an in vivo feasibility study including (a) 3-dimensional (3D) gradient echo (GRE) imaging, (b) inversion recovery 3D GRE imaging, and (c) 2D T2-weighted fast spin-echo imaging. For this purpose, healthy adult volunteers (n = 17; mean age, 34 ± 11 years) and patients with intraocular masses (uveal melanoma, n = 5; mean age, 57 ± 6 years) were investigated. All subjects tolerated all examinations well with no relevant adverse events. The 6-channel coil array supports high-resolution 3D GRE imaging with a spatial resolution as good as 0.2 × 0.2 × 1.0 mm, which facilitates the depiction of anatomical details of the eye. Rather, uniform signal intensity across the eye was found. A mean signal-to-noise ratio of approximately 35 was found for the lens, whereas the vitreous humor showed a signal-to-noise ratio of approximately 30. The lens-vitreous humor contrast-to-noise ratio was 8, which allows good differentiation between the lens and the vitreous compartment. Inversion recovery prepared 3D GRE imaging using a spatial resolution of 0.4 × 0.4 × 1.0 mm was found to be feasible. T2-weighted 2D fast spin-echo imaging with the proposed RF coil afforded a spatial resolution of 0.25 × 0.25 × 0.7 mm. This work provides valuable information on the feasibility of ophthalmic MRI at 7 T using a dedicated 6-channel transceiver coil array that supports the acquisition of high-contrast, high-spatial resolution images in healthy volunteers and patients with intraocular masses. The results underscore the challenges of ocular imaging at 7 T and demonstrate that these issues can be offset by using tailored RF coil hardware. The benefits of such improvements would be in positive alignment with explorations that are designed to examine the potential of MRI for the assessment of spatial arrangements of the eye segments and their masses with the ultimate goal to provide imaging means for guiding treatment decisions in ophthalmological diseases.
Progress in Cell Marking for Synchrotron X-ray Computed Tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hall, Christopher; Sturm, Erica; Schultke, Elisabeth
2010-07-23
Recently there has been an increase in research activity into finding ways of marking cells in live animals for pre-clinical trials. Development of certain drugs and other therapies crucially depend on tracking particular cells or cell types in living systems. Therefore cell marking techniques are required which will enable longitudinal studies, where individuals can be examined several times over the course of a therapy or study. The benefits of being able to study both disease and therapy progression in individuals, rather than cohorts are clear. The need for high contrast 3-D imaging, without harming or altering the biological system requiresmore » a non-invasive yet penetrating imaging technique. The technique will also have to provide an appropriate spatial and contrast resolution. X-ray computed tomography offers rapid acquisition of 3-D images and is set to become one of the principal imaging techniques in this area. Work by our group over the last few years has shown that marking cells with gold nano-particles (GNP) is an effective means of visualising marked cells in-vivo using x-ray CT. Here we report the latest results from these studies. Synchrotron X-ray CT images of brain lesions in rats taken using the SYRMEP facility at the Elettra synchrotron in 2009 have been compared with histological examination of the tissues. Some deductions are drawn about the visibility of the gold loaded cells in both light microscopy and x-ray imaging.« less
Progress in Cell Marking for Synchrotron X-ray Computed Tomography
NASA Astrophysics Data System (ADS)
Hall, Christopher; Sturm, Erica; Schultke, Elisabeth; Arfelli, Fulvia; Menk, Ralf-Hendrik; Astolfo, Alberto; Juurlink, Bernhard H. J.
2010-07-01
Recently there has been an increase in research activity into finding ways of marking cells in live animals for pre-clinical trials. Development of certain drugs and other therapies crucially depend on tracking particular cells or cell types in living systems. Therefore cell marking techniques are required which will enable longitudinal studies, where individuals can be examined several times over the course of a therapy or study. The benefits of being able to study both disease and therapy progression in individuals, rather than cohorts are clear. The need for high contrast 3-D imaging, without harming or altering the biological system requires a non-invasive yet penetrating imaging technique. The technique will also have to provide an appropriate spatial and contrast resolution. X-ray computed tomography offers rapid acquisition of 3-D images and is set to become one of the principal imaging techniques in this area. Work by our group over the last few years has shown that marking cells with gold nano-particles (GNP) is an effective means of visualising marked cells in-vivo using x-ray CT. Here we report the latest results from these studies. Synchrotron X-ray CT images of brain lesions in rats taken using the SYRMEP facility at the Elettra synchrotron in 2009 have been compared with histological examination of the tissues. Some deductions are drawn about the visibility of the gold loaded cells in both light microscopy and x-ray imaging.
Local Variability of Parameters for Characterization of the Corneal Subbasal Nerve Plexus.
Winter, Karsten; Scheibe, Patrick; Köhler, Bernd; Allgeier, Stephan; Guthoff, Rudolf F; Stachs, Oliver
2016-01-01
The corneal subbasal nerve plexus (SNP) offers high potential for early diagnosis of diabetic peripheral neuropathy. Changes in subbasal nerve fibers can be assessed in vivo by confocal laser scanning microscopy (CLSM) and quantified using specific parameters. While current study results agree regarding parameter tendency, there are considerable differences in terms of absolute values. The present study set out to identify factors that might account for this high parameter variability. In three healthy subjects, we used a novel method of software-based large-scale reconstruction that provided SNP images of the central cornea, decomposed the image areas into all possible image sections corresponding to the size of a single conventional CLSM image (0.16 mm2), and calculated a set of parameters for each image section. In order to carry out a large number of virtual examinations within the reconstructed image areas, an extensive simulation procedure (10,000 runs per image) was implemented. The three analyzed images ranged in size from 3.75 mm2 to 4.27 mm2. The spatial configuration of the subbasal nerve fiber networks varied greatly across the cornea and thus caused heavily location-dependent results as well as wide value ranges for the parameters assessed. Distributions of SNP parameter values varied greatly between the three images and showed significant differences between all images for every parameter calculated (p < 0.001 in each case). The relatively small size of the conventionally evaluated SNP area is a contributory factor in high SNP parameter variability. Averaging of parameter values based on multiple CLSM frames does not necessarily result in good approximations of the respective reference values of the whole image area. This illustrates the potential for examiner bias when selecting SNP images in the central corneal area.
Vegting, Yosta; Reneman, Liesbeth; Booij, Jan
2016-10-01
Ecstasy is a commonly used psychoactive drug with 3,4-methylenedioxymethamphetamine (MDMA) as the main content. Importantly, it has been suggested that use of MDMA may be neurotoxic particularly for serotonergic (5-hydroxytryptamine (5-HT)) neurons. In the past decades, several molecular imaging studies examined directly in vivo the effects of ecstasy/MDMA on neurotransmitter systems. The objective of the present study is to review the effects of ecstasy/MDMA on neurotransmitter systems as assessed by molecular imaging studies in small animals, non-human primates and humans. A search in PubMed was performed. Eighty-eight articles were found on which inclusion and exclusion criteria were applied. Thirty-three studies met the inclusion criteria; all were focused on the 5-HT or dopamine (DA) system. Importantly, 9 out of 11 of the animal studies that examined the effects of MDMA on 5-HT transporter (SERT) availability showed a significant loss of binding potential. In human studies, this was the case for 14 out of 16 studies, particularly in heavy users. In abstinent users, significant recovery of SERT binding was found over time. Most imaging studies in humans that focused on the DA system did not find any significant effect of ecstasy/MDMA use. Preclinical and clinical molecular imaging studies on the effects of ecstasy/MDMA use/administration on neurotransmitter systems show quite consistent alterations of the 5-HT system. Particularly, in human studies, loss of SERT binding was observed in heavy ecstasy users, which might reflect 5-HT neurotoxicity, although alternative explanations (e.g. down-regulation of the SERT) cannot be excluded.
The evidential value of distorted and rectified digital images in footwear imprint examination.
Shor, Yaron; Chaikovsky, Alan; Tsach, Tsadok
2006-06-27
The procedure for forensic photography requires that the film plane be parallel to the taken image. Another procedure must be used when the print is located on reflecting surfaces such as vehicles, or faint marks on porous surfaces. Examination was made of the evidential value of footprint images received from the scene or taken deliberately at an angle out of proper perspective (i.e., the lens axis is not perpendicular to the target plane). An artificial target was prepared and photographed from several lens axis angles ranging from 10 degrees to 85 degrees to the perpendicular, and then rectified using the Adobe Photoshop Version 7.0. It was found that at angles less than 40 degrees , the shape and location of all the individual characteristics were similar enough in comparison to the original image. In images taken at higher angles, the original image could not be adequately restored. The full potential of this image, therefore, could not be achieved after rectification. The results of this study show that the images of a footprint taken at an angle less than 40 degrees , preserve the evidential value of the unique characteristics.
NASA Astrophysics Data System (ADS)
Je, U. K.; Cho, H. M.; Cho, H. S.; Park, Y. O.; Park, C. K.; Lim, H. W.; Kim, K. S.; Kim, G. A.; Park, S. Y.; Woo, T. H.; Choi, S. I.
2016-02-01
In this paper, we propose a new/next-generation type of CT examinations, the so-called Interior Computed Tomography (ICT), which may presumably lead to dose reduction to the patient outside the target region-of-interest (ROI), in dental x-ray imaging. Here an x-ray beam from each projection position covers only a relatively small ROI containing a target of diagnosis from the examined structure, leading to imaging benefits such as decreasing scatters and system cost as well as reducing imaging dose. We considered the compressed-sensing (CS) framework, rather than common filtered-backprojection (FBP)-based algorithms, for more accurate ICT reconstruction. We implemented a CS-based ICT algorithm and performed a systematic simulation to investigate the imaging characteristics. Simulation conditions of two ROI ratios of 0.28 and 0.14 between the target and the whole phantom sizes and four projection numbers of 360, 180, 90, and 45 were tested. We successfully reconstructed ICT images of substantially high image quality by using the CS framework even with few-view projection data, still preserving sharp edges in the images.
Diagnostic ultrasound at MACH 20: retroperitoneal and pelvic imaging in space.
Jones, J A; Sargsyan, A E; Barr, Y R; Melton, S; Hamilton, D R; Dulchavsky, S A; Whitson, P A
2009-07-01
An operationally available diagnostic imaging capability augments spaceflight medical support by facilitating the diagnosis, monitoring and treatment of medical or surgical conditions, by improving medical outcomes and, thereby, by lowering medical mission impacts and the probability of crew evacuation due to medical causes. Microgravity-related physiological changes occurring during spaceflight can affect the genitourinary system and potentially cause conditions such as urinary retention or nephrolithiasis for which ultrasonography (U/S) would be a useful diagnostic tool. This study describes the first genitourinary ultrasound examination conducted in space, and evaluates image quality, frame rate, resolution requirements, real-time remote guidance of nonphysician crew medical officers and evaluation of on-orbit tools that can augment image acquisition. A nonphysician crew medical officer (CMO) astronaut, with minimal training in U/S, performed a self-examination of the genitourinary system onboard the International Space Station, using a Philips/ATL Model HDI-5000 ultrasound imaging unit located in the International Space Station Human Research Facility. The CMO was remotely guided by voice commands from experienced, earth-based sonographers stationed in Mission Control Center in Houston. The crewmember, with guidance, was able to acquire all of the target images. Real-time and still U/S images received at Mission Control Center in Houston were of sufficient quality for the images to be diagnostic for multiple potential genitourinary applications. Microgravity-based ultrasound imaging can provide diagnostic quality images of the retroperitoneum and pelvis, offering improved diagnosis and treatment for onboard medical contingencies. Successful completion of complex sonographic examinations can be obtained even with minimally trained nonphysician ultrasound operators, with the assistance of ground-based real-time guidance.
Walker, D Catherine; White, Emily K; Srinivasan, Vamshek J
2018-04-16
Body checking (BC) and body image avoidance (BIA) have been proposed as etiological and maintaining mechanisms for eating disorder (ED) pathology. To date, no comprehensive review summarizes the relationships of BC and BIA with ED pathology, body image dissatisfaction, or mood/affect. Meta-analyses examined the relationships of BC and BIA with ED pathology, body image dissatisfaction, and mood/affect. Gender, publication status, and presence or absence of ED diagnoses were examined as potential moderators. Results showed strong relationships between BC and ED pathology (ρ = 0.588) and BC and body image dissatisfaction (ρ = 0.631) and a moderate relationship between BC and mood/affect (ρ = 0.385). Similarly, results showed strong relationships between BIA and ED pathology (ρ = 0.553) and BIA and body image dissatisfaction (ρ = 0.543) and a moderate relationship between BIA and mood/affect (ρ = 0.392). Overall, limited evidence supported publication bias; however, publication bias may exist in the relationship between BIA and body image dissatisfaction in the literature. Subgroup moderator analyses suggested that gender moderates the strength of the relationships between BC and ED pathology, body image dissatisfaction, and mood/affect and between BIA and body image dissatisfaction. Results are consistent with cognitive-behavioral models of ED pathology that suggest BC and BIA are behavioral expressions of overvaluation of weight and shape. Notably, more published research has investigated BC than BIA. Future studies, incorporating methods such as meta-analytic structural equation modeling, should examine these variables to further test cognitive-behavioral models of ED development and maintenance. © 2018 Wiley Periodicals, Inc.
Lavdas, Eleftherios; Mavroidis, Panayiotis; Kostopoulos, Spiros; Glotsos, Dimitrios; Roka, Violeta; Koutsiaris, Aristotle G; Batsikas, Georgios; Sakkas, Georgios K; Tsagkalis, Antonios; Notaras, Ioannis; Stathakis, Sotirios; Papanikolaou, Nikos; Vassiou, Katerina
2013-07-01
The purpose of this study is to evaluate the ability of T2 turbo spin echo (TSE) axial and sagittal BLADE sequences in reducing or even eliminating motion, pulsatile flow and cross-talk artifacts in lumbar spine MRI examinations. Forty four patients, who had routinely undergone a lumbar spine examination, participated in the study. The following pairs of sequences with and without BLADE were compared: a) T2 TSE Sagittal (SAG) in thirty two cases, and b) T2 TSE Axial (AX) also in thirty two cases. Both quantitative and qualitative analyses were performed based on measurements in different normal anatomical structures and examination of seven characteristics, respectively. The qualitative analysis was performed by experienced radiologists. Also, the presence of image motion, pulsatile flow and cross-talk artifacts was evaluated. Based on the results of the qualitative analysis for the different sequences and anatomical structures, the BLADE sequences were found to be significantly superior to the conventional ones in all the cases. The BLADE sequences eliminated the motion artifacts in all the cases. In our results, it was found that in the examined sequences (sagittal and axial) the differences between the BLADE and conventional sequences regarding the elimination of motion, pulsatile flow and cross-talk artifacts were statistically significant. In all the comparisons, the T2 TSE BLADE sequences were significantly superior to the corresponding conventional sequences regarding the classification of their image quality. In conclusion, this technique appears to be capable of potentially eliminating motion, pulsatile flow and cross-talk artifacts in lumbar spine MR images and producing high quality images in collaborative and non-collaborative patients. Copyright © 2013 Elsevier Inc. All rights reserved.
Csutak, Csaba; Badea, Radu; Bolboaca, Sorana D; Ordeanu, Claudia; Nagy, Viorica M; Fekete, Zsolt; Chiorean, Liliana; Dudea, Sorin M
2016-03-01
The aim of this study was to evaluate the use of pre and post-therapy transrectal and transvaginal ultrasonography (TRUS, TVUS) with contrast enhancement and strain elastography compared with clinical examination and magnetic resonance imaging (MRI) in the assessment of advanced stage cervical cancer. This was a prospective study, carried out over a period of nine months on subjects with advanced-stage cervical cancer (stage >/= IIB). All included patients were examined clinically and underwent abdomino-pelvic contrast enhanced MRI and multimodal US examinations (TRUS with strain elastography and contrast enhanced TVUS) at the time of diagnosis and after radiochemotherapy. Tumor size and staging at TRUS and TVUS was compared with the same data obtained by clinical examination and MRI. Pathology was the golden standard. Eight patients accomplished the inclusion criteria. In five cases the tumor stage was identical on clinical and MRI examinations. In all cases parametrial infiltration was diagnosed by all pre-treatment examinations. No significant differences were observed in tumor size between clinical, US and MRI exams either at baseline or post-therapy, in native or post-contrast examinations. The size of the tumor evaluated pre-treatment proved to be significantly smaller post-contrast in both US and MRI examinations compared with the native images. Post-therapy, no significant differences were observed on US measured tumor dimensions when comparing native with post-contrast images. Oppositely, significant smaller dimensions were observed on post-contrast MRI compared with native scans. TRUS is accurate in the estimation of pre-therapy cervical cancer dimension. The post therapy tumor evaluation is better performed with MRI. The use of intravenous contrast agents on both examinations did not improved the accuracy of tumor evaluation pre or post-therapy.
Ultrasound and other imaging technologies in the intensive care unit.
Lee, S Y; Frankel, H L
2000-06-01
As technology advances, more imaging and procedures are performed at the bedside on critically ill patients in ICUs, thereby eliminating the risks of transporting patients. These imaging techniques can serve as diagnostic and therapeutic tools in treating the acute and chronic consequences of injured, critically ill patients. One area of growth is ultrasonography. Critical care applications of ultrasonography are expanding, and the learning curve of surgeons and intensivists performing some of these studies is improving. Ultrasonography can supplement physical examination and provide useful "real-time" information on nearly every body cavity. Other imaging technology is also available in a portable form, enabling imaging directly at the bedside. Images are now becoming readily and easily available with the advancement of teleradiology. Some of the imaging modalities are still in development, and their clinical effectiveness is being studied. In the future, more uses of these various imaging technologies may become evident and cost-effective.
Auditing The Completeness and Legibility of Computerized Radiological Request Forms.
Al Muallem, Yahya; Al Dogether, Majed; Househ, Mowafa; Saddik, Basema
2017-11-04
Certain Saudi healthcare organizations transfer outpatients to medical imaging departments for radiological examinations in a manual process that relies on the use of paper-based forms. With the increased implementation of electronic medical records in Saudi Hospitals, little is known about the completeness and legibility of information captured in electronic-based medical imaging forms. The purpose of this study is to audit the completeness and legibility of medical imaging paper-based forms in comparison with electronic-based medical imaging forms. As a secondary objective, we also examined the number of errors found on the forms.An observational retrospective cross-sectional study was utilized to audit the completeness and legibility of both paper and electronic forms collected between March 1 and May 15, 2015. The study measured the association among categorical variables using Chi-Square analysis. The results of this investigation show a significant association between form completion and type of record (i.e., paper vs. electronic) where electronic-based systems were found to be more complete than paper-based records. Electrnoic based records were also found to improve form legibility, promote user adherence to complete the forms and minimize entry errors. In conclusion, electronic-based medical imaging forms are more complete and legible than paper based forms. Future studies should evaluate other hospitals and compare both legibility and completeness of electronic-based medical imaging forms and conduct usability evaluation studies with users to explore the impacts of system design on both completeness and legibility of electronic forms, in general, but more specifically, electronic-based medical imaging forms.
Rotator cuff crepitus: could Codman really feel a cuff tear?
Ponce, Brent A; Kundukulam, Joseph A; Sheppard, Evan D; Determann, Jason R; McGwin, Gerald; Narducci, Carl A; Crowther, Marshall J
2014-07-01
The objective of this study was to assess the accuracy of palpating crepitus to diagnose rotator cuff tears. Seventy consecutive consenting patients who presented with shoulder pain and no previous imaging or surgery on the affected shoulder were prospectively enrolled during a 10-month period. A standardized patient history and examination, including the crepitus test, were recorded in addition to obtaining standard radiographs. Additional imaging after initial evaluation was performed with magnetic resonance imaging and interpreted by a musculoskeletal radiologist blinded to the examination findings. Statistical analysis was used to determine sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the crepitus test in the clinical diagnosis of a rotator cuff tear. Sixty-three patients had histories, examinations, and imaging studies available for analysis. The crepitus test had a sensitivity of 67%, specificity of 80%, PPV of 91%, and NPV of 43% for all types of rotator cuff tears. The sensitivity and specificity for full-thickness or high-grade partial tears was 82% and 73%, respectively; the PPV and NPV were 77% and 79%. Increasing age improved accuracy as the presence of crepitus in patients older than 55 years had a sensitivity of 76%, specificity of 100%, PPV of 100%, and NPV of 38%. The crepitus test has a favorable sensitivity, specificity, PPV, and NPV to assess the integrity of the rotator cuff and may be a useful examination in the clinical diagnosis of a rotator cuff tear. Published by Mosby, Inc.
Clinically Unjustified Diagnostic Imaging – a Worrisome Tendency in Today’s Medical Practice
Sobiecka, Aleksandra; Bekiesińska-Figatowska, Monika; Rutkowska, Milena; Latos, Tomasz; Walecki, Jerzy
2016-01-01
Summary Background The purpose of the study was to evaluate the percentage of unjustified examinations among all the CT and MRI studies performed by two radiology departments and to determine the types of examinations which are most commonly carried out unnecessarily. Material/Methods Three radiologists assessed the justification of CT and MRI examinations performed during a period of 14 days based on the referrals. The radiologists assessed 799 referrals for CT scans (847 examinations of a particular part of the body) and 269 MRI referrals (269 examinations). The criteria for justification were: medical expertise and the guidelines. During the first stage radiologists divided the examinations into 3 groups: justified, unjustified and the examinations of questionable justification. The second step was to determine the reasons why the studies were considered as unjustified or of questionable justification. Results 73 of 1116 examinations (6.54%) were considered to be unjustified or of a questionable justification. There were 59 CT scans (59/847=6.97%) and 14 MRI studies (14/269=5.20%). The most common reasons to consider them as unjustified or of questionable justification were: inadequate method of diagnostic imaging chosen as a first-line tool and lacking or insufficient clinical details. Conclusions In our investigation 6.54% of both CT and MRI examinations were considered as unjustified or of questionable justification, which is lower than described in other studies (from 7% to 26%). The assessment was based only on referrals, therefore a total share of these examinations is likely to be higher. PMID:27471577
RANZCR Body Systems Framework of diagnostic imaging examination descriptors.
Pitman, Alexander G; Penlington, Lisa; Doromal, Darren; Slater, Gregory; Vukolova, Natalia
2014-08-01
A unified and logical system of descriptors for diagnostic imaging examinations and procedures is a desirable resource for radiology in Australia and New Zealand and is needed to support core activities of RANZCR. Existing descriptor systems available in Australia and New Zealand (including the Medicare DIST and the ACC Schedule) have significant limitations and are inappropriate for broader clinical application. An anatomically based grid was constructed, with anatomical structures arranged in rows and diagnostic imaging modalities arranged in columns (including nuclear medicine and positron emission tomography). The grid was segregated into five body systems. The cells at the intersection of an anatomical structure row and an imaging modality column were populated with short, formulaic descriptors of the applicable diagnostic imaging examinations. Clinically illogical or physically impossible combinations were 'greyed out'. Where the same examination applied to different anatomical structures, the descriptor was kept identical for the purposes of streamlining. The resulting Body Systems Framework of diagnostic imaging examination descriptors lists all the reasonably common diagnostic imaging examinations currently performed in Australia and New Zealand using a unified grid structure allowing navigation by both referrers and radiologists. The Framework has been placed on the RANZCR website and is available for access free of charge by registered users. The Body Systems Framework of diagnostic imaging examination descriptors is a system of descriptors based on relationships between anatomical structures and imaging modalities. The Framework is now available as a resource and reference point for the radiology profession and to support core College activities. © 2014 The Royal Australian and New Zealand College of Radiologists.
MRI assessment of local acute radiation syndrome.
Weber-Donat, G; Amabile, J-C; Lahutte-Auboin, M; Potet, J; Baccialone, J; Bey, E; Teriitehau, C; Laroche, P
2012-12-01
To describe local acute radiation syndrome and its radiological imaging characteristics. We performed a retrospective study of patients who had suffered skin and deeper radiation damage who were investigated by magnetic resonance imaging (MRI). We compared the clinical findings, C-reactive protein (CRP) levels and MRI results. A total of 22 MRI examinations were performed between 2005 and 2010 in 7 patients; 6 patients had increased CRP levels and MRI abnormalities. They were treated by surgery and local cellular therapy. One patient had no CRP or MRI abnormalities, and had a spontaneous good outcome. Eighteen abnormal MR examinations demonstrated high STIR signal and/or abnormal enhancement in the dermis and muscle tissues. Three MRI examinations demonstrated skeletal abnormalities, consistent with radionecrosis. The four normal MRI examinations were associated only with minor clinical manifestations such as pain and pigmentation disorders. MRI seems to be a useful and promising imaging investigation in radiation burns management i.e. initial lesion evaluation, treatment evaluation and complication diagnosis. MRI findings correlated perfectly with clinical stage and no false negative examinations were obtained. In particular, the association between normal MRI and low CRP level seems to be related to good outcome without specific treatment. Local acute radiation syndrome (radioepidermitis) mainly affects the skin and superficial tissues. MRI findings correspond with clinical stage (with a strong negative predictive value). MRI outperformed X-ray examination for the diagnosis of bone radionecrosis. Diffusion-weighted imaging shows low ADC in bone and soft tissue necrosis. Perfusion sequence allows assessment of tissue microcirculation impairment.
Physical Examination of Knee Ligament Injuries.
Bronstein, Robert D; Schaffer, Joseph C
2017-04-01
The knee is one of the most commonly injured joints in the body. A thorough history and physical examination of the knee facilitates accurate diagnosis of ligament injury. Several examination techniques for the knee ligaments that were developed before advanced imaging remain as accurate or more accurate than these newer imaging modalities. Proper use of these examination techniques requires an understanding of the anatomy and pathophysiology of knee ligament injuries. Advanced imaging can be used to augment a history and examination when necessary, but should not replace a thorough history and physical examination.
Normal Rates of Neuroradiological Findings in Children with High Functioning Autism
ERIC Educational Resources Information Center
Vasa, Roma A.; Ranta, Marin; Huisman, Thierry A. G. M.; Pinto, Pedro S.; Tillman, Rachael M.; Mostofsky, Stewart H.
2012-01-01
Magnetic resonance imaging (MRI) has been used to analyze highly specific volumetric and morphological features of the brains of individuals with autism spectrum disorder (ASD). To date, there are few comprehensive studies examining the prevalence of neuroradiologic findings seen on routine MRI scans in children with ASD. This study examined the…
Solomon, Howard M; Makris, Susan L; Alsaid, Hasan; Bermudez, Oscar; Beyer, Bruce K; Chen, Antong; Chen, Connie L; Chen, Zhou; Chmielewski, Gary; DeLise, Anthony M; de Schaepdrijver, Luc; Dogdas, Belma; French, Julian; Harrouk, Wafa; Helfgott, Jonathan; Henkelman, R Mark; Hesterman, Jacob; Hew, Kok-Wah; Hoberman, Alan; Lo, Cecilia W; McDougal, Andrew; Minck, Daniel R; Scott, Lelia; Stewart, Jane; Sutherland, Vicki; Tatiparthi, Arun K; Winkelmann, Christopher T; Wise, L David; Wood, Sandra L; Ying, Xiaoyou
2016-06-01
During the past two decades the use and refinements of imaging modalities have markedly increased making it possible to image embryos and fetuses used in pivotal nonclinical studies submitted to regulatory agencies. Implementing these technologies into the Good Laboratory Practice environment requires rigorous testing, validation, and documentation to ensure the reproducibility of data. A workshop on current practices and regulatory requirements was held with the goal of defining minimal criteria for the proper implementation of these technologies and subsequent submission to regulatory agencies. Micro-computed tomography (micro-CT) is especially well suited for high-throughput evaluations, and is gaining popularity to evaluate fetal skeletons to assess the potential developmental toxicity of test agents. This workshop was convened to help scientists in the developmental toxicology field understand and apply micro-CT technology to nonclinical toxicology studies and facilitate the regulatory acceptance of imaging data. Presentations and workshop discussions covered: (1) principles of micro-CT fetal imaging; (2) concordance of findings with conventional skeletal evaluations; and (3) regulatory requirements for validating the system. Establishing these requirements for micro-CT examination can provide a path forward for laboratories considering implementing this technology and provide regulatory agencies with a basis to consider the acceptability of data generated via this technology. Published by Elsevier Inc.
Leveraging simulation to evaluate system performance in presence of fixed pattern noise
NASA Astrophysics Data System (ADS)
Teaney, Brian P.
2017-05-01
The development of image simulation techniques which map the effects of a notional, modeled sensor system onto an existing image can be used to evaluate the image quality of camera systems prior to the development of prototype systems. In addition, image simulation or `virtual prototyping' can be utilized to reduce the time and expense associated with conducting extensive field trials. In this paper we examine the development of a perception study designed to assess the performance of the NVESD imager performance metrics as a function of fixed pattern noise. This paper discusses the development of the model theory and the implementation and execution of the perception study. In addition, other applications of the image simulation component including the evaluation of limiting resolution and other test targets is provided.
Muslim Women in America and Hijab: A Study of Empowerment, Feminist Identity, and Body Image.
Al Wazni, Anderson Beckmann
2015-10-01
This article presents an exploratory, qualitative study of 12 Muslim women living in the Triangle area of North Carolina, who were interviewed regarding their voluntary practice of hijab (Muslim tradition of veiling), exercise of choice in hijab, their relationship to feminist belief and identity, female empowerment, and body image. Through examining the influence of political movements in concert with market capitalism, this article examines how the hijab and those who voluntarily practice this Muslim tradition challenge or contradict mainstream images of what is marketed in the West as feminist. Moreover, this article seeks to examine how, if at all, the hijab empowers those women who practice it, whether it offers an avenue of female empowerment and liberation not traditionally included in prevailing feminist thought, and how this may contribute to third-wave feminist theory. This article informs social work practitioners of the strength of Muslim women, the exercise of choice in hijab, and contributions to feminist thought as participants respond to assumptions of oppression, patriarchal control, and prejudice in a post-9/11 society.
Swami, Viren; Tran, Ulrich S; Brooks, Louise Hoffmann; Kanaan, Laura; Luesse, Ellen-Marlene; Nader, Ingo W; Pietschnig, Jakob; Stieger, Stefan; Voracek, Martin
2013-04-01
Studies have suggested associations between personality dimensions and body image constructs, but these have not been conclusively established. In two studies, we examined direct associations between the Big Five dimensions and two body image constructs, actual-ideal weight discrepancy and body appreciation. In Study 1, 950 women completed measures of both body image constructs and a brief measure of the Big Five dimensions. In Study 2,339 women completed measures of the body image constructs and a more reliable measure of the Big Five. Both studies showed that Neuroticism was significantly associated with actual-ideal weight discrepancy (positively) and body appreciation (negatively) once the effects of body mass index and social status had been accounted for. These results are consistent with the suggestion that Neuroticism is a trait of public health significance requiring attention by body image scholars. © 2012 The Authors. Scandinavian Journal of Psychology © 2012 The Scandinavian Psychological Associations.
ERIC Educational Resources Information Center
Rampal, A.
1992-01-01
Examines trends in teachers' beliefs about scientists and the nature of science. Discusses teachers' questionnaire responses on the following qualities of scientists: minimum educational qualifications; creativity; temperament; stereotyped image; and personal beliefs about indigenous systems of medicine and astrology. (Contains 63 references.)…
Prospective Computer Teachers' Mental Images about the Concepts of "School" and "Computer Teacher"
ERIC Educational Resources Information Center
Saban, Aslihan
2011-01-01
In this phenomenological study, prospective computer teachers' mental images related to the concepts of "school" and "computer teacher" were examined through metaphors. Participants were all the 45 seniors majoring in the Department of Computer and Instructional Technologies at Selcuk University, Ahmet Kelesoglu Faculty of…
Functional Imaging of Working Memory and Peripheral Endothelial Function in Middle-Aged Adults
ERIC Educational Resources Information Center
Gonzales, Mitzi M.; Tarumi, Takashi; Tanaka, Hirofumi; Sugawara, Jun; Swann-Sternberg, Tali; Goudarzi, Katayoon; Haley, Andreana P.
2010-01-01
The current study examined the relationship between a prognostic indicator of vascular health, flow-mediated dilation (FMD), and working memory-related brain activation in healthy middle-aged adults. Forty-two participants underwent functional magnetic resonance imaging while completing a 2-Back working memory task. Brachial artery…
Sexy versus Strong: What Girls and Women Think of Female Athletes
ERIC Educational Resources Information Center
Daniels, Elizabeth A.
2012-01-01
Little research has investigated girls' and college women's reactions to non-objectified media images of women, including those that depict women in instrumental activities like playing a sport. This study examined open-ended responses to images of performance athletes, sexualized athletes, and sexualized models. Participants were 258 adolescent…
Images of Men and Women in Indian Textbooks.
ERIC Educational Resources Information Center
Kalia, Narendra Nath
1980-01-01
This study examined 41 Hindi or English language instruction textbooks widely used in Indian high school/higher secondary or preuniversity instruction. Frequency of male and female characters, their images, and their occupations were tabulated. Results indicate that Indian textbooks still present a stereotyped view of dominant males and…
Content Analysis of Science Teacher Representations in Google Images
ERIC Educational Resources Information Center
Bergman, Daniel
2017-01-01
Teacher images can impact numerous perceptions in educational settings, as well as through popular media. The portrayal of effective science teaching is especially challenging to specify, given the complex nature of science inquiry and other standards-based practices. The present study examined the litany of representations of science teachers…
Fundus autofluorescence imaging in an ocular screening program.
Kolomeyer, A M; Nayak, N V; Szirth, B C; Khouri, A S
2012-01-01
Purpose. To describe integration of fundus autofluorescence (FAF) imaging into an ocular screening program. Methods. Fifty consecutive screening participants were included in this prospective pilot imaging study. Color and FAF (530/640 nm exciter/barrier filters) images were obtained with a 15.1MP Canon nonmydriatic hybrid camera. A clinician evaluated the images on site to determine need for referral. Visual acuity (VA), intraocular pressure (IOP), and ocular pathology detected by color fundus and FAF imaging modalities were recorded. Results. Mean ± SD age was 47.4 ± 17.3 years. Fifty-two percent were female and 58% African American. Twenty-seven percent had a comprehensive ocular examination within the past year. Mean VA was 20/39 in the right eye and 20/40 in the left eye. Mean IOP was 15 mmHg bilaterally. Positive color and/or FAF findings were identified in nine (18%) individuals with diabetic retinopathy or macular edema (n = 4), focal RPE defects (n = 2), age-related macular degeneration (n = 1), central serous retinopathy (n = 1), and ocular trauma (n = 1). Conclusions. FAF was successfully integrated in our ocular screening program and aided in the identification of ocular pathology. Larger studies examining the utility of this technology in screening programs may be warranted.
Fundus Autofluorescence Imaging in an Ocular Screening Program
Kolomeyer, A. M.; Nayak, N. V.; Szirth, B. C.; Khouri, A. S.
2012-01-01
Purpose. To describe integration of fundus autofluorescence (FAF) imaging into an ocular screening program. Methods. Fifty consecutive screening participants were included in this prospective pilot imaging study. Color and FAF (530/640 nm exciter/barrier filters) images were obtained with a 15.1MP Canon nonmydriatic hybrid camera. A clinician evaluated the images on site to determine need for referral. Visual acuity (VA), intraocular pressure (IOP), and ocular pathology detected by color fundus and FAF imaging modalities were recorded. Results. Mean ± SD age was 47.4 ± 17.3 years. Fifty-two percent were female and 58% African American. Twenty-seven percent had a comprehensive ocular examination within the past year. Mean VA was 20/39 in the right eye and 20/40 in the left eye. Mean IOP was 15 mmHg bilaterally. Positive color and/or FAF findings were identified in nine (18%) individuals with diabetic retinopathy or macular edema (n = 4), focal RPE defects (n = 2), age-related macular degeneration (n = 1), central serous retinopathy (n = 1), and ocular trauma (n = 1). Conclusions. FAF was successfully integrated in our ocular screening program and aided in the identification of ocular pathology. Larger studies examining the utility of this technology in screening programs may be warranted. PMID:23316224
Caumo, Francesca; Zorzi, Manuel; Brunelli, Silvia; Romanucci, Giovanna; Rella, Rossella; Cugola, Loredana; Bricolo, Paola; Fedato, Chiara; Montemezzi, Stefania; Houssami, Nehmat
2018-04-01
Purpose To examine the outcomes of a breast cancer screening program based on digital breast tomosynthesis (DBT) plus synthesized two-dimensional (2D) mammography compared with those after full-field digital mammography (FFDM). Materials and Methods This prospective study included 16 666 asymptomatic women aged 50-69 years who were recruited in April 2015 through March 2016 for DBT plus synthetic 2D screening in the Verona screening program. A comparison cohort of women screened with FFDM (n = 14 423) in the previous year was included. Screening detection measures for the two groups were compared by calculating the proportions associated with each outcome, and the relative rates (RRs) were estimated with multivariate logistic regression. Results Cancer detection rate (CDR) for DBT plus synthetic 2D imaging was 9.30 per 1000 screening examinations versus 5.41 per 1000 screening examinations with FFDM (RR, 1.72; 95% confidence interval [CI]: 1.30, 2.29). CDR was significantly higher in patients screened with DBT plus synthetic 2D imaging than in those screened with FFDM among women classified as having low breast density (RR, 1.53; 95% CI: 1.13, 2.10) or high breast density (RR, 2.86; 95% CI: 1.42, 6.25). The positive predictive value (PPV) for recall was almost doubled with DBT plus synthetic 2D imaging: 23.3% versus 12.9% of recalled patients who were screened with FFDM (RR, 1.81; 95% CI: 1.34, 2.47). The recall rate was similar between groups (RR, 0.95; 95% CI: 0.84, 1.06), whereas the recall rate with invasive assessment was higher for DBT plus synthetic 2D imaging than for FFDM (RR, 1.93; 95% CI: 1.31, 2.03). The mean number of screening studies interpreted per hour was significantly lower for screening examinations performed with DBT plus synthetic 2D imaging (38.5 screens per hour) than with FFDM (60 screens per hour) (P < .001). Conclusion DBT plus synthetic 2D imaging increases CDRs with recall rates comparable to those of FFDM. DBT plus synthetic 2D imaging increased image reading time and the time needed for invasive assessments. © RSNA, 2017.
Single-image hard-copy display of the spine utilizing digital radiography
NASA Astrophysics Data System (ADS)
Artz, Dorothy S.; Janchar, Timothy; Milzman, David; Freedman, Matthew T.; Mun, Seong K.
1997-04-01
Regions of the entire spine contain a wide latitude of tissue densities within the imaged field of view presenting a problem for adequate radiological evaluation. With screen/film technology, the optimal technique for one area of the radiograph is sub-optimal for another area. Computed radiography (CR) with its inherent wide dynamic range, has been shown to be better than screen/film for lateral cervical spine imaging, but limitations are still present with standard image processing. By utilizing a dynamic range control (DRC) algorithm based on unsharp masking and signal transformation prior to gradation and frequency processing within the CR system, more vertebral bodies can be seen on a single hard copy display of the lateral cervical, thoracic, and thoracolumbar examinations. Examinations of the trauma cross-table lateral cervical spine, lateral thoracic spine, and lateral thoracolumbar spine were collected on live patient using photostimulable storage phosphor plates, the Fuji FCR 9000 reader, and the Fuji AC-3 computed radiography reader. Two images were produced from a single exposure; one with standard image processing and the second image with the standard process and the additional DRC algorithm. Both sets were printed from a Fuji LP 414 laser printer. Two different DRC algorithms were applied depending on which portion of the spine was not well visualized. One algorithm increased optical density and the second algorithm decreased optical density. The resultant image pairs were then reviewed by a panel of radiologists. Images produced with the additional DRC algorithm demonstrated improved visualization of previously 'under exposed' and 'over exposed' regions within the same image. Where lung field had previously obscured bony detail of the lateral thoracolumbar spine due to 'over exposure,' the image with the DRC applied to decrease the optical density allowed for easy visualization of the entire area of interest. For areas of the lateral cervical spine and lateral thoracic spine that typically have a low optical density value, the DRC algorithm used increased the optical density over that region improving visualization of C7-T2 and T11-L2 vertebral bodies; critical in trauma radiography. Emergency medicine physicians also reviewing the lateral cervical spine images were able to clear 37% of the DRC images compared to 30% of the non-DRC images for removal of the cervical collar. The DRC processed images reviewed by the physicians do not have a typical screen/film appearance; however, these different images were preferred for the three examinations in this study. This method of image processing after being tested and accepted, is in use clinically at Georgetown University Medical Center Department of Radiology for the following examinations: cervical spine, lateral thoracic spine, lateral thoracolumbar examinations, facial bones, shoulder, sternum, feet and portable chest. Computed radiography imaging of the spine is improved with the addition of histogram equalization known as dynamic range control (DRC). More anatomical structures are visualized on a single hard copy display.
Magnetic resonance imaging as a tool for extravehicular activity analysis
NASA Technical Reports Server (NTRS)
Dickenson, R.; Lorenz, C.; Peterson, S.; Strauss, A.; Main, J.
1992-01-01
The purpose of this research is to examine the value of magnetic resonance imaging (MRI) as a means of conducting kinematic studies of the hand for the purpose of EVA capability enhancement. After imaging the subject hand using a magnetic resonance scanner, the resulting 2D slices were reconstructed into a 3D model of the proximal phalanx of the left hand. Using the coordinates of several landmark positions, one is then able to decompose the motion of the rigid body. MRI offers highly accurate measurements due to its tomographic nature without the problems associated with other imaging modalities for in vivo studies.
Developing Matlab scripts for image analysis and quality assessment
NASA Astrophysics Data System (ADS)
Vaiopoulos, A. D.
2011-11-01
Image processing is a very helpful tool in many fields of modern sciences that involve digital imaging examination and interpretation. Processed images however, often need to be correlated with the original image, in order to ensure that the resulting image fulfills its purpose. Aside from the visual examination, which is mandatory, image quality indices (such as correlation coefficient, entropy and others) are very useful, when deciding which processed image is the most satisfactory. For this reason, a single program (script) was written in Matlab language, which automatically calculates eight indices by utilizing eight respective functions (independent function scripts). The program was tested in both fused hyperspectral (Hyperion-ALI) and multispectral (ALI, Landsat) imagery and proved to be efficient. Indices were found to be in agreement with visual examination and statistical observations.
Maa, April Y; Patel, Shivangi; Chasan, Joel E; Delaune, William; Lynch, Mary G
2017-01-01
Diabetic teleretinal screening programs have been utilized successfully across the world to detect diabetic retinopathy (DR) and are well validated. Less information, however, exists on the ability of teleretinal imaging to detect nondiabetic ocular pathology. This study performed a retrospective evaluation to assess the ability of a community-based diabetic teleretinal screening program to detect common ocular disease other than DR. A retrospective chart review of 1,774 patients who underwent diabetic teleretinal screening was performed. Eye clinic notes from the Veterans Health Administration's electronic medical record, Computerized Patient Record System, were searched for each of the patients screened through teleretinal imaging. When a face-to-face examination note was present, the physical findings were compared to those obtained through teleretinal imaging. Sensitivity, specificity, and positive and negative predictive values were calculated for suspicious nerve, cataract, and age-related macular degeneration. A total of 903 patients underwent a clinical examination. The positive predictive value was highest for cataract (100%), suspicious nerve (93%), and macular degeneration (90%). The negative predictive value and the percent agreement between teleretinal imaging and a clinical examination were over 90% for each disease category. A teleretinal imaging protocol may be used to screen for other common ocular diseases. It may be feasible to use diabetic teleretinal photographs to screen patients for other potential eye diseases. Additional elements of the eye workup may be added to enhance accuracy of disease detection. Further study is necessary to confirm this initial retrospective review.
da Silva, Kassy Gomes; de Andrade, Carla; Sotomaior, Cristina Santos
2017-07-17
Presence of significant quantities of gas in the intestines may hinder a proper conduction of abdominal ultrasonography. In humans, preparatory techniques are used to solve this, but measures to avoid ultrasonographic complications due to intestinal gas in rabbits have not been reported. The objective of this study was to evaluate the influence of fasting and simethicone administered orally on the quality of ultrasonographic images of the gallbladder, kidneys, and jejunum in adult New Zealand White (NZW) rabbits. A total of 28 adult NZW rabbits were included in a crossover design study, involving four groups: F: fasting for 4-6 h before the examination; FS: fasting and application of simethicone (20 mg/kg, orally) 20 to 30 min before the examination; S: application of simethicone 20-30 min before the examination without fasting; and C: controls without fasting and no application of simethicone. Evaluation of the ultrasonographic images was done in terms of percentage of visualization of each organ and image quality using a 3-point scoring system (unacceptable, acceptable, or excellent). The kidneys and the gallbladder were visualized at an equal frequency in all groups, while the jejunum was visualized more frequently in the FS group. The image quality scores for gallbladder, right kidney, and left kidney was similar for all groups, but for the jejunum, a higher number of images with acceptable scores was found within the FS group.
Evaluation of pleural and pericardial effusions by magnetic resonance imaging.
Tscholakoff, D; Sechtem, U; de Geer, G; Schmidt, H; Higgins, C B
1987-08-01
MR examinations of 36 patients with pleural and/or pericardial effusions were retrospectively evaluated. The purpose of this study was to determine of MR imaging is capable of differentiating between pleural and pericardial effusions of different compositions using standard electrocardiogram (ECG)-gated and non-gated spin echo pulse sequences. Additional data was obtained from experimental pleural effusions in 10 dogs. The results of this study indicate that old hemorrhages into the pleural or pericardial space can be differentiated from other pleural or pericardial effusions. However, further differentiation between transudates, exudates and sanguinous effusions is not possible on MR images acquired with standard spin echo pulse sequences. Respiratory and cardiac motion are responsible for signal loss, particularly on first echo images. This was documented in experiments in dogs with induced effusions of known composition; "negative" T2 values consistent with fluid motion during imaging sequences were observed in 80% of cases. However, postmortem studies of the dogs with experimental effusions showed differences between effusions with low protein concentrations and higher protein concentrations. We conclude from our study that characterization of pleural and pericardial effusions on standard ECG-gated and non-gated MR examinations is limited to the positive identification of hemorrhage. Motion of the fluid due to cardiac and respiratory activity causes artifactual and unpredictable changes in intensity values negating the more subtle differences in intensity associated with increasing protein content.
Yager, Zali; O'Dea, Jennifer
2010-10-01
This study examined the impact of two interventions on body image, eating disorder risk and excessive exercise among 170 (65% female) trainee health education and physical education (HE&PE) teachers of mean (standard deviation) age 21.6 (2.3) who were considered an 'at-risk' population for poor body image and eating disorders. In the first year of the study, the control group cohort (n = 49 females, 20 males) received the regular didactic health education curriculum; in the second year of the study, the Intervention 1 cohort (n = 31 females, 21 males) received a self-esteem and media literacy health education program and in the third year of the study, the Intervention 2 cohort (n = 30 females, 19 males) received a combined self-esteem, media literacy and dissonance program using online and computer-based activities. Intervention 2 produced the best results, with males improving significantly in self-esteem, body image and drive for muscularity. Intervention 2 females improved significantly on Eating Disorders Inventory Drive for Thinness, Eating Disorder Examination and excessive exercise. The improvements were consistent at 6-month follow-up for females. It is feasible to promote body image, reduce body dissatisfaction and reduce excessive exercise among trainee HE&PE teachers via a health education curriculum.
Ni, X-G; Zhang, Q-Q; Wang, G-Q
2016-11-01
This study aimed to compare the diagnostic effectiveness of narrow band imaging and autofluorescence imaging for malignant laryngopharyngeal tumours. Between May 2010 and October 2010, 50 consecutive patients with suspected laryngopharyngeal tumour underwent endoscopic laryngopharynx examination. The morphological characteristics of laryngopharyngeal lesions were analysed using high performance endoscopic systems equipped with narrow band imaging and autofluorescence imaging modes. The diagnostic effectiveness of white light image, narrow band imaging and autofluorescence imaging endoscopy for benign and malignant laryngopharyngeal lesions was evaluated. Under narrow band imaging endoscopy, the superficial microvessels of squamous cell carcinomas appeared as dark brown spots or twisted cords. Under autofluorescence imaging endoscopy, malignant lesions appeared as bright purple. The sensitivity of malignant lesion diagnosis was not significantly different between narrow band imaging and autofluorescence imaging modes, but was better than for white light image endoscopy (χ2 = 12.676, p = 0.002). The diagnostic specificity was significantly better in narrow band imaging mode than in both autofluorescence imaging and white light imaging mode (χ2 = 8.333, p = 0.016). Narrow band imaging endoscopy is the best option for the diagnosis and differential diagnosis of laryngopharyngeal tumours.
Harvey, H. Benjamin; Gilman, Matthew D.; Wu, Carol C.; Cushing, Matthew S.; Halpern, Elkan F.; Zhao, Jing; Pandharipande, Pari V.; Shepard, Jo-Anne O.
2015-01-01
Purpose To evaluate the diagnostic yield of recommended chest computed tomography (CT) prompted by abnormalities detected on outpatient chest radiographic images. Materials and Methods This HIPAA-compliant study had institutional review board approval; informed consent was waived. Reports of all outpatient chest radiographic examinations performed at a large academic center during 2008 (n = 29 138) were queried to identify studies that included a recommendation for a chest CT imaging. The radiology information system was queried for these patients to determine if a chest CT examination was obtained within 1 year of the index radiographic examination that contained the recommendation. For chest CT examinations obtained within 1 year of the index chest radiographic examination and that met inclusion criteria, chest CT images were reviewed to determine if there was an abnormality that corresponded to the chest radiographic finding that prompted the recommendation. All corresponding abnormalities were categorized as clinically relevant or not clinically relevant, based on whether further work-up or treatment was warranted. Groups were compared by using t test and Fisher exact test with a Bonferroni correction applied for multiple comparisons. Results There were 4.5% (1316 of 29138 [95% confidence interval {CI}: 4.3%, 4.8%]) of outpatient chest radiographic examinations that contained a recommendation for chest CT examination, and increasing patient age (P < .001) and positive smoking history (P = .001) were associated with increased likelihood of a recommendation for chest CT examination. Of patients within this subset who met inclusion criteria, 65.4% (691 of 1057 [95% CI: 62.4%, 68.2%) underwent a chest CT examination within the year after the index chest radiographic examination. Clinically relevant corresponding abnormalities were present on chest CT images in 41.4% (286 of 691 [95% CI: 37.7%, 45.2%]) of cases, nonclinically relevant corresponding abnormalities in 20.6% (142 of 691 [95% CI: 17.6%, 23.8%]) of cases, and no corresponding abnormalities in 38.1% (263 of 691 [95% CI: 34.4%, 41.8%]) of cases. Newly diagnosed, biopsy-proven malignancies were detected in 8.1% (56 of 691 [95% CI: 6.2%, 10.4%]) of cases. Conclusion A radiologist recommendation for chest CT to evaluate an abnormal finding on an outpatient chest radiographic examination has a high yield of clinically relevant findings. © RSNA, 2014 PMID:25531242
The role of point of care ultrasound in prehospital critical care: a systematic review.
Bøtker, Morten Thingemann; Jacobsen, Lars; Rudolph, Søren Steemann; Knudsen, Lars
2018-06-26
In 2011, the role of Point of Care Ultrasound (POCUS) was defined as one of the top five research priorities in physician-provided prehospital critical care and future research topics were proposed; the feasibility of prehospital POCUS, changes in patient management induced by POCUS and education of providers. This systematic review aimed to assess these three topics by including studies examining all kinds of prehospital patients undergoing all kinds of prehospital POCUS examinations and studies examining any kind of POCUS education in prehospital critical care providers. By a systematic literature search in MEDLINE, EMBASE, and Cochrane databases, we identified and screened titles and abstracts of 3264 studies published from 2012 to 2017. Of these, 65 studies were read in full-text for assessment of eligibility and 27 studies were ultimately included and assessed for quality by SIGN-50 checklists. No studies compared patient outcome with and without prehospital POCUS. Four studies of acceptable quality demonstrated feasibility and changes in patient management in trauma. Two studies of acceptable quality demonstrated feasibility and changes in patient management in breathing difficulties. Four studies of acceptable quality demonstrated feasibility, outcome prediction and changes in patient management in cardiac arrest, but also that POCUS may prolong pauses in compressions. Two studies of acceptable quality demonstrated that short (few hours) teaching sessions are sufficient for obtaining simple interpretation skills, but not image acquisition skills. Three studies of acceptable quality demonstrated that longer one- or two-day courses including hands-on training are sufficient for learning simple, but not advanced, image acquisition skills. Three studies of acceptable quality demonstrated that systematic educational programs including supervised examinations are sufficient for learning advanced image acquisition skills in healthy volunteers, but that more than 50 clinical examinations are required for expertise in a clinical setting. Prehospital POCUS is feasible and changes patient management in trauma, breathing difficulties and cardiac arrest, but it is unknown if this improves outcome. Expertise in POCUS requires extensive training by a combination of theory, hands-on training and a substantial amount of clinical examinations - a large part of these needs to be supervised.
Aurumskjöld, Marie-Louise; Söderberg, Marcus; Stålhammar, Fredrik; von Steyern, Kristina Vult; Tingberg, Anders; Ydström, Kristina
2018-06-01
Background In pediatric patients, computed tomography (CT) is important in the medical chain of diagnosing and monitoring various diseases. Because children are more radiosensitive than adults, they require minimal radiation exposure. One way to achieve this goal is to implement new technical solutions, like iterative reconstruction. Purpose To evaluate the potential of a new, iterative, model-based method for reconstructing (IMR) pediatric abdominal CT at a low radiation dose and determine whether it maintains or improves image quality, compared to the current reconstruction method. Material and Methods Forty pediatric patients underwent abdominal CT. Twenty patients were examined with the standard dose settings and 20 patients were examined with a 32% lower radiation dose. Images from the standard examination were reconstructed with a hybrid iterative reconstruction method (iDose 4 ), and images from the low-dose examinations were reconstructed with both iDose 4 and IMR. Image quality was evaluated subjectively by three observers, according to modified EU image quality criteria, and evaluated objectively based on the noise observed in liver images. Results Visual grading characteristics analyses showed no difference in image quality between the standard dose examination reconstructed with iDose 4 and the low dose examination reconstructed with IMR. IMR showed lower image noise in the liver compared to iDose 4 images. Inter- and intra-observer variance was low: the intraclass coefficient was 0.66 (95% confidence interval = 0.60-0.71) for the three observers. Conclusion IMR provided image quality equivalent or superior to the standard iDose 4 method for evaluating pediatric abdominal CT, even with a 32% dose reduction.
Body image and sexual function in women after treatment for anal and rectal cancer.
Benedict, Catherine; Philip, Errol J; Baser, Raymond E; Carter, Jeanne; Schuler, Tammy A; Jandorf, Lina; DuHamel, Katherine; Nelson, Christian
2016-03-01
Treatment for anal and rectal cancer (ARCa) often results in side effects that directly impact sexual functioning; however, ARCa survivors are an understudied group, and factors contributing to the sexual sequelae are not well understood. Body image problems are distressing and may further exacerbate sexual difficulties, particularly for women. This preliminary study sought to (1) describe body image problems, including sociodemographic and disease/treatment correlates, and (2) examine relations between body image and sexual function. For the baseline assessment of a larger study, 70 women completed the European Organization for Research and Treatment of Cancer Core Quality of Life Questionnaire and Colorectal Cancer-specific Module, including the Body Image subscale, and Female Sexual Function Index. Pearson's correlation and multiple regression evaluated correlates of body image. Among sexually active women (n = 41), hierarchical regression examined relations between body image and sexual function domains. Women were on average 55 years old (standard deviation = 11.6), non-Hispanic White (79%), married (57%), and employed (47%). The majority (86%) reported at least one body image problem. Younger age, lower global health status, and greater severity of symptoms related to poorer body image (p's < 0.05). Poor body image was inversely related to all aspects of sexual function (β range 0.50-0.70, p's < 0.05), except pain. The strongest association was with Female Sexual Function Index Sexual/Relationship Satisfaction. These preliminary findings suggest the importance of assessing body image as a potentially modifiable target to address sexual difficulties in this understudied group. Further longitudinal research is needed to inform the development and implementation of effective interventions to improve the sexual health and well-being of female ARCa survivors. Copyright © 2015 John Wiley & Sons, Ltd.
Body Image and Sexual Function in Women after Treatment for Anal and Rectal Cancer
Benedict, Catherine; Philip, Errol J.; Baser, Raymond E.; Carter, Jeanne; Schuler, Tammy A.; Jandorf, Lina; DuHamel, Katherine; Nelson, Christian
2016-01-01
Objective Treatment for anal and rectal cancer (ARCa) often results in side effects that directly impact sexual functioning; however, ARCa survivors are an understudied group and factors contributing to the sexual sequelae are not well understood. Body image problems are distressing and may further exacerbate sexual difficulties, particularly for women. This preliminary study sought to (1) describe body image problems, including sociodemographic and disease/treatment correlates; and (2) examine relations between body image and sexual function. Methods For the baseline assessment of a larger study, 70 women completed the EORTC QLQ-C30 and CR38, including the Body Image subscale, and Female Sexual Function Index (FSFI). Pearson’s correlation and multiple regression evaluated correlates of body image. Among sexually active women (n=41), hierarchical regression examined relations between body image and sexual function domains. Results Women were an average 55 years old (SD=11.6), Non-Hispanic White (79%), married (57%), and employed (47%). The majority (86%) reported at least one body image problem. Younger age, lower global health status, and greater severity of symptoms related to poorer body image (p’s<.05). Poor body image was inversely related to all aspects of sexual function (β range .50 to .70, p’s<.05), except pain. The strongest association was with FSFI Sexual/Relationship Satisfaction. Conclusion These preliminary findings suggest the importance of assessing body image as a potentially modifiable target to address sexual difficulties in this understudied group. Further longitudinal research is needed to inform the development and implementation of effective interventions to improve the sexual health and well-being of female ARCa survivors. PMID:25974874
Body image and borderline personality disorder among psychiatric inpatients.
Sansone, Randy A; Chu, Jamie W; Wiederman, Michael W
2010-01-01
With the exclusion of studies in individuals with eating disorders, few investigators have examined body image issues in patients with borderline personality disorder (BPD). In this study, we examined among psychiatric inpatients relationships between body image and BPD. In a cross-sectional sample of convenience, we surveyed 126 women in an inpatient psychiatric unit using 5 measures for body image and 2 measures for BPD. Using standardized cutoffs for BPD diagnosis, participants with BPD demonstrated a number of differentiating features with regard to body image issues. Explicitly, BPD did not seem to be related to being self-conscious about one's appearance, although BPD was related to being more self-conscious, in general. Individuals with BPD were not more invested in their appearance as a source of self-definition but evaluated their own appearance more negatively and were more likely to believe that attractiveness is an important factor for happiness and acceptance. Although BPD was not related to perceptions about the strength and competence of one's own body, those with BPD indicated less comfort and trust in their own bodies. In general, it appeared that body image measures that were more perceptually grounded were more likely to be similar to non-BPD participants, whereas body image measures that were more cognitively grounded were more likely to be statistically significantly different in comparison with non-BPD participants. Psychiatric inpatients with BPD demonstrate a number of disturbances in body image. Copyright © 2010 Elsevier Inc. All rights reserved.
Morphologic 3D scanning of fallopian tubes to assist ovarian cancer diagnosis
NASA Astrophysics Data System (ADS)
Madore, Wendy-Julie; De Montigny, Etienne; Deschênes, Andréanne; Benboujja, Fouzi; Leduc, Mikael; Mes-Masson, Anne-Marie; Provencher, Diane M.; Rahimi, Kurosh; Boudoux, Caroline; Godbout, Nicolas
2016-02-01
Pathological evaluation of the fallopian tubes is an important diagnostic result but tumors can be missed using routine approaches. As the majority of high-grade serous ovarian cancers are now believed to originate in the fallopian tubes, pathological examination should include in a thorough examination of the excised ovaries and fallopian tubes. We present an dedicated imaging system for diagnostic exploration of human fallopian tubes. This system is based on optical coherence tomography (OCT), a laser imaging modality giving access to sub- epithelial tissue architecture. This system produces cross-sectional images up to 3 mm in depth, with a lateral resolution of ≍15μm and an axial resolution of ≍12μm. An endoscopic single fiber probe was developed to fit in a human fallopian tube. This 1.2 mm probe produces 3D volume data of the entire inner tube within a few minutes. To demonstrate the clinical potential of OCT for lesion identification, we studied 5 different ovarian lesions and healthy fallopian tubes. We imaged 52 paraffin-embedded human surgical specimens with a benchtop system and compared these images with histology slides. We also imaged and compared healthy oviducts from 3 animal models to find one resembling the human anatomy and to develop a functional ex vivo imaging procedure with the endoscopic probe. We also present an update on an ongoing clinical pilot study on women undergoing prophylactic or diagnostic surgery in which we image ex vivo fallopian tubes with the endoscopic probe.
Google Glass for Documentation of Medical Findings: Evaluation in Forensic Medicine
2014-01-01
Background Google Glass is a promising premarket device that includes an optical head-mounted display. Several proof of concept reports exist, but there is little scientific evidence regarding its use in a medical setting. Objective The objective of this study was to empirically determine the feasibility of deploying Glass in a forensics setting. Methods Glass was used in combination with a self-developed app that allowed for hands-free operation during autopsy and postmortem examinations of 4 decedents performed by 2 physicians. A digital single-lens reflex (DSLR) camera was used for image comparison. In addition, 6 forensic examiners (3 male, 3 female; age range 23-48 years, age mean 32.8 years, SD 9.6; mean work experience 6.2 years, SD 8.5) were asked to evaluate 159 images for image quality on a 5-point Likert scale, specifically color discrimination, brightness, sharpness, and their satisfaction with the acquired region of interest. Statistical evaluations were performed to determine how Glass compares with conventionally acquired digital images. Results All images received good (median 4) and very good ratings (median 5) for all 4 categories. Autopsy images taken by Glass (n=32) received significantly lower ratings than those acquired by DSLR camera (n=17) (region of interest: z=–5.154, P<.001; sharpness: z=–7.898, P<.001; color: z=–4.407, P<.001, brightness: z=–3.187, P=.001). For 110 images of postmortem examinations (Glass: n=54, DSLR camera: n=56), ratings for region of interest (z=–8.390, P<.001) and brightness (z=–540, P=.007) were significantly lower. For interrater reliability, intraclass correlation (ICC) values were good for autopsy (ICC=.723, 95% CI .667-.771, P<.001) and postmortem examination (ICC=.758, 95% CI .727-.787, P<.001). Postmortem examinations performed using Glass took 42.6 seconds longer than those done with the DSLR camera (z=–2.100, P=.04 using Wilcoxon signed rank test). The battery charge of Glass quickly decreased; an average 5.5% (SD 1.85) of its battery capacity was spent per postmortem examination (0.81% per minute or 0.79% per picture). Conclusions Glass was efficient for acquiring images for documentation in forensic medicine, but the image quality was inferior compared to a DSLR camera. Images taken with Glass received significantly lower ratings for all 4 categories in an autopsy setting and for region of interest and brightness in postmortem examination. The effort necessary for achieving the objectives was higher when using the device compared to the DSLR camera thus extending the postmortem examination duration. Its relative high power consumption and low battery capacity is also a disadvantage. At the current stage of development, Glass may be an adequate tool for education. For deployment in clinical care, issues such as hygiene, data protection, and privacy need to be addressed and are currently limiting chances for professional use. PMID:24521935
Google Glass for documentation of medical findings: evaluation in forensic medicine.
Albrecht, Urs-Vito; von Jan, Ute; Kuebler, Joachim; Zoeller, Christoph; Lacher, Martin; Muensterer, Oliver J; Ettinger, Max; Klintschar, Michael; Hagemeier, Lars
2014-02-12
Google Glass is a promising premarket device that includes an optical head-mounted display. Several proof of concept reports exist, but there is little scientific evidence regarding its use in a medical setting. The objective of this study was to empirically determine the feasibility of deploying Glass in a forensics setting. Glass was used in combination with a self-developed app that allowed for hands-free operation during autopsy and postmortem examinations of 4 decedents performed by 2 physicians. A digital single-lens reflex (DSLR) camera was used for image comparison. In addition, 6 forensic examiners (3 male, 3 female; age range 23-48 years, age mean 32.8 years, SD 9.6; mean work experience 6.2 years, SD 8.5) were asked to evaluate 159 images for image quality on a 5-point Likert scale, specifically color discrimination, brightness, sharpness, and their satisfaction with the acquired region of interest. Statistical evaluations were performed to determine how Glass compares with conventionally acquired digital images. All images received good (median 4) and very good ratings (median 5) for all 4 categories. Autopsy images taken by Glass (n=32) received significantly lower ratings than those acquired by DSLR camera (n=17) (region of interest: z=-5.154, P<.001; sharpness: z=-7.898, P<.001; color: z=-4.407, P<.001, brightness: z=-3.187, P=.001). For 110 images of postmortem examinations (Glass: n=54, DSLR camera: n=56), ratings for region of interest (z=-8.390, P<.001) and brightness (z=-540, P=.007) were significantly lower. For interrater reliability, intraclass correlation (ICC) values were good for autopsy (ICC=.723, 95% CI .667-.771, P<.001) and postmortem examination (ICC=.758, 95% CI .727-.787, P<.001). Postmortem examinations performed using Glass took 42.6 seconds longer than those done with the DSLR camera (z=-2.100, P=.04 using Wilcoxon signed rank test). The battery charge of Glass quickly decreased; an average 5.5% (SD 1.85) of its battery capacity was spent per postmortem examination (0.81% per minute or 0.79% per picture). Glass was efficient for acquiring images for documentation in forensic medicine, but the image quality was inferior compared to a DSLR camera. Images taken with Glass received significantly lower ratings for all 4 categories in an autopsy setting and for region of interest and brightness in postmortem examination. The effort necessary for achieving the objectives was higher when using the device compared to the DSLR camera thus extending the postmortem examination duration. Its relative high power consumption and low battery capacity is also a disadvantage. At the current stage of development, Glass may be an adequate tool for education. For deployment in clinical care, issues such as hygiene, data protection, and privacy need to be addressed and are currently limiting chances for professional use.
Clinical imaging of the pancreas
DOE Office of Scientific and Technical Information (OSTI.GOV)
May, G.; Gardiner, R.
1987-01-01
Featuring more than 300 high-quality radiographs and scan images, clinical imaging of the pancreas systematically reviews all appropriate imaging modalities for diagnosing and evaluating a variety of commonly encountered pancreatic disorders. After presenting a succinct overview of pancreatic embryology, anatomy, and physiology, the authors establish the clinical indications-including postoperative patient evaluation-for radiologic examination of the pancreas. The diagnostic capabilities and limitations of currently available imaging techniques for the pancreas are thoroughly assessed, with carefully selected illustrations depicting the types of images and data obtained using these different techniques. The review of acute and chronic pancreatitis considers the clinical features andmore » possible complications of their variant forms and offers guidance in selecting appropriate imaging studies.« less
Adult self-image and well-being after testicular cancer: The role of agency and meaning.
Ryan, Sean J; Hoyt, Michael A
2018-08-01
Cancer during young adulthood can limit the extent to which one adopts an adult self-image. However, the relationship of adult self-image to cancer-related adjustment remains unexplored. The current study examines relationships of adult self-image and social/emotional well-being and job-related problems in young testicular cancer survivors. Factors thought to facilitate future-oriented goals (i.e. agency and meaning) are examined as intermediary processes. Testicular cancer survivors (N = 171) between the ages of 18 and 29 completed questionnaire measures of adult self-image, agency, sense of meaning and indicators of adjustment. Social and emotional well-being were measured by the Functional Assessment of Cancer Therapy-General. Job problems were assessed using the EORTC's testicular cancer supplement (EORTC QLQ-TC26). Path model results revealed direct associations of survivors' adult self-image with social (β = .20, p < .05), but not emotional well-being (β = .14, p < .01). Both agency and meaning mediated the relationship of adult self-image and well-being indicators. Finally, the relationship between adult self-image and job problems was only significant for those who were employed or in school (β = -.19, p < .05). Assessment of adult self-image might be useful in identifying risk for poor adjustment. Interventions that target agency and meaning might facilitate developmental goals.
Object recognition of real targets using modelled SAR images
NASA Astrophysics Data System (ADS)
Zherdev, D. A.
2017-12-01
In this work the problem of recognition is studied using SAR images. The algorithm of recognition is based on the computation of conjugation indices with vectors of class. The support subspaces for each class are constructed by exception of the most and the less correlated vectors in a class. In the study we examine the ability of a significant feature vector size reduce that leads to recognition time decrease. The images of targets form the feature vectors that are transformed using pre-trained convolutional neural network (CNN).
Communicator image and Myers-Briggs Type Indicator extraversion-introversion.
Opt, Susan K; Loffredo, Donald A
2003-11-01
This study is an examination of the relationship between communicator image and Myers-Briggs Type Indicator (MBTI) dimensions of extraversion-introversion. The authors found that individuals who prefer extraversion tend to have a more positive communicator image than those who prefer introversion. The results of this study support other research results showing that personality preferences differ in communication behaviors and traits, which could have implications for the individual's comfort and success in society. Results of this research also support the contention that communication behavior has biological aspects.
X-Ray Phantom Development For Observer Performance Studies
NASA Astrophysics Data System (ADS)
Kelsey, C. A.; Moseley, R. D.; Mettler, F. A.; Parker, T. W.
1981-07-01
The requirements for radiographic imaging phantoms for observer performance testing include realistic tasks which mimic at least some portion of the diagnostic examination presented in a setting which approximates clinically derived images. This study describes efforts to simulate chest and vascular diseases for evaluation of conventional and digital radiographic systems. Images of lung nodules, pulmonary infiltrates, as well as hilar and mediastinal masses are generated with a conventional chest phantom to make up chest disease test series. Vascular images are simulated by hollow tubes embedded in tissue density plastic with widening and narrowing added to mimic aneurysms and stenoses. Both sets of phantoms produce images which allow simultaneous determination of true positive and false positive rates as well as complete ROC curves.
Fluoroscopic studies of the upper gastrointestinal tract: techniques and indications.
Sánchez-Carpintero de la Vega, M; García Villar, C
Fluoroscopic studies of the gastrointestinal tract are becoming increasing less common due to the introduction of other imaging techniques such as computed tomography and magnetic resonance imaging and to the increased availability of endoscopy. Nevertheless, fluoroscopic studies of the gastrointestinal tract continue to appear in clinical guidelines and some of their indications are still valid. These studies are dynamic, operator-dependent examinations that require training to obtain the maximum diagnostic performance. This review aims to describe the technique and bring the indications for this imaging modality up to date. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
NASA Technical Reports Server (NTRS)
Selzer, Robert H. (Inventor); Hodis, Howard N. (Inventor)
2011-01-01
A standardized acquisition methodology assists operators to accurately replicate high resolution B-mode ultrasound images obtained over several spaced-apart examinations utilizing a split-screen display in which the arterial ultrasound image from an earlier examination is displayed on one side of the screen while a real-time "live" ultrasound image from a current examination is displayed next to the earlier image on the opposite side of the screen. By viewing both images, whether simultaneously or alternately, while manually adjusting the ultrasound transducer, an operator is able to bring into view the real-time image that best matches a selected image from the earlier ultrasound examination. Utilizing this methodology, dynamic material properties of arterial structures, such as IMT and diameter, are measured in a standard region over successive image frames. Each frame of the sequence has its echo edge boundaries automatically determined by using the immediately prior frame's true echo edge coordinates as initial boundary conditions. Computerized echo edge recognition and tracking over multiple successive image frames enhances measurement of arterial diameter and IMT and allows for improved vascular dimension measurements, including vascular stiffness and IMT determinations.
Hänni, Mari; Edvardsson, H; Wågberg, M; Pettersson, K; Smedby, O
2004-01-01
The need for a quantitative method to assess atherosclerosis in vivo is well known. This study tested, in a familiar animal model of atherosclerosis, a combination of magnetic resonance imaging (MRI) and image processing. Six spontaneously hyperlipidemic (Watanabe) rabbits were examined with a knee coil in a 1.5-T clinical MRI scanner. Inflow angio (2DI) and proton density weighted (PDW) images were acquired to examine 10 cm of the aorta immediately cranial to the aortic bifurcation. Examination of the thoracic aorta was added in four animals. To identify the inner and outer boundary of the arterial wall, a dynamic contour algorithm (Gradient Vector Flow snakes) was applied to the 2DI and PDW images, respectively, after which the vessel wall area was calculated. The results were compared with histopathological measurements of intima and intima-media cross-sectional area. The correlation coefficient between wall area measurements with MRI snakes and intima-media area was 0.879 when computed individual-wise for abdominal aortas, 0.958 for thoracic aortas, and 0.834 when computed segment-wise. When the algorithm was applied to the PDW images only, somewhat lower correlations were obtained. The MRI yielded significantly higher values than histopathology, which excludes the adventitia. Magnetic resonance imaging, in combination with dynamic contours, may be a suitable technique for quantitative assessment of atherosclerosis in vivo. Using two sequences for the measurement seems to be superior to using a single sequence.
ERIC Educational Resources Information Center
Hayes, Sharon; Tantleff-Dunn, Stacey
2010-01-01
The current study investigated the effects of brief exposure to appearance-related media on young girls' body image. One hundred and twenty-one girls aged 3-6 years old participated. Results indicated that exposure did not affect body dissatisfaction or engagement in appearance-related play behaviours. This is the first empirical study to provide…
Stahl, Stephane; Hentschel, Pascal; Ketelsen, Dominik; Grosse, Ulrich; Held, Manuel; Wahler, Theodora; Syha, Roland; Schaller, Hans-Eberhard; Nikolaou, Konstantin; Grözinger, Gerd
2017-05-01
This prospective clinical study examined standard wrist magnetic resonance imaging (MRI) examinations and the incremental value of computed tomography (CT) in the diagnosis of Kienböck's disease (KD) with regard to reliability and precision in the different diagnostic steps during diagnostic work-up. Sixty-four consecutive patients referred between January 2009 and January 2014 with positive initial suspicion of KD according to external standard wrist MRI were prospectively included (step one). Institutional review board approval was obtained. Clinical examination by two handsurgeons were followed by wrist radiographs (step two), ultrathin-section CT, and 3T contrast-enhanced MRI (step three). Final diagnosis was established in a consensus conference involving all examiners and all examinations results available from step three. In 12/64 patients, initial suspicion was discarded at step two and in 34/64 patients, the initial suspicion of KD was finally discarded at step three. The final external MRI positive predictive value was 47%. The most common differential diagnoses at step three were intraosseous cysts (n=15), lunate pseudarthrosis (n=13), and ulnar impaction syndrome (n=5). A correlation between radiograph-based diagnoses (step two) with final diagnosis (step three) showed that initial suspicion of stage I KD had the lowest sensitivity for correct diagnosis (2/11). Technical factors associated with a false positive external MRI KD diagnosis were not found. Standard wrist MRI should be complemented with thin-section CT, and interdisciplinary interpretation of images and clinical data, to increase diagnostic accuracy in patients with suspected KD. Copyright © 2017. Published by Elsevier B.V.
Examination of Painting on Metal Support by Terahertz Time-Domain Imaging
NASA Astrophysics Data System (ADS)
Koch Dandolo, C. L.; Gomez-Sepulveda, A. M.; Hernandez-Serrano, A. I.; Castro-Camus, E.
2017-10-01
Two paintings on metal support have been imaged by terahertz time-domain imaging (THz-TDI) in a reflection setup and the X-ray radiographs were also recorded. The study was performed for testing the terahertz radiation (THz) as an imaging method alternative to X-ray radiography, which suffers several limitations in imaging paint layers on metal support. While the information regarding the paint layers of the paintings was almost lost in the records provided by the X-ray radiography, THz-TDI demonstrates the ability to provide important information about them, despite the presence of the underlying metal.
Diagnosis of basal cell carcinoma by two photon excited fluorescence combined with lifetime imaging
NASA Astrophysics Data System (ADS)
Fan, Shunping; Peng, Xiao; Liu, Lixin; Liu, Shaoxiong; Lu, Yuan; Qu, Junle
2014-02-01
Basal cell carcinoma (BCC) is the most common type of human skin cancer. The traditional diagnostic procedure of BCC is histological examination with haematoxylin and eosin staining of the tissue biopsy. In order to reduce complexity of the diagnosis procedure, a number of noninvasive optical methods have been applied in skin examination, for example, multiphoton tomography (MPT) and fluorescence lifetime imaging microscopy (FLIM). In this study, we explored two-photon optical tomography of human skin specimens using two-photon excited autofluorescence imaging and FLIM. There are a number of naturally endogenous fluorophores in skin sample, such as keratin, melanin, collagen, elastin, flavin and porphyrin. Confocal microscopy was used to obtain structures of the sample. Properties of epidermic and cancer cells were characterized by fluorescence emission spectra, as well as fluorescence lifetime imaging. Our results show that two-photon autofluorescence lifetime imaging can provide accurate optical biopsies with subcellular resolution and is potentially a quantitative optical diagnostic method in skin cancer diagnosis.
Jin, Taoran; Shen, Hongrui; Zhao, Zhe; Hu, Jing
2014-11-01
In this study, the authors examined the clinical manifestations, skeletal muscle pathological characteristics, and neuroimaging results of 2 cases of Leigh syndrome in a Chinese family. The 2 patients presented with general weakness, and 1 of them presented with an impairment of vision. Skeletal muscle biopsies showed a deficiency in cytochrome c oxidase levels. Brain magnetic resonance imaging showed increased T1 and T2 signal intensities in the centrum ovale and dentate nucleus. Diffusion-weighted imaging showed a high-intensity signal. Magnetic resonance spectroscopy showed elevated levels of lactic acid in lesions. The examination of 1 patient at disease onset and during disease remission showed that the lesions detected by magnetic resonance imaging and diffusion-weighted imaging, and the peak for lactic acid detected by magnetic resonance spectroscopy, decreased during remission. These data suggest that changes in the imaging results of patients with Leigh syndrome correlate with disease course and pathogenetic condition. © The Author(s) 2014.
NASA Astrophysics Data System (ADS)
Peng, Dong; Du, Yang; Shi, Yiwen; Mao, Duo; Jia, Xiaohua; Li, Hui; Zhu, Yukun; Wang, Kun; Tian, Jie
2016-07-01
Photoacoustic imaging and fluorescence molecular imaging are emerging as important research tools for biomedical studies. Photoacoustic imaging offers both strong optical absorption contrast and high ultrasonic resolution, and fluorescence molecular imaging provides excellent superficial resolution, high sensitivity, high throughput, and the ability for real-time imaging. Therefore, combining the imaging information of both modalities can provide comprehensive in vivo physiological and pathological information. However, currently there are limited probes available that can realize both fluorescence and photoacoustic imaging, and advanced biomedical applications for applying this dual-modality imaging approach remain underexplored. In this study, we developed a dual-modality photoacoustic-fluorescence imaging nanoprobe, ICG-loaded Au@SiO2, which was uniquely designed, consisting of gold nanorod cores and indocyanine green with silica shell spacer layers to overcome fluorophore quenching. This nanoprobe was examined by both PAI and FMI for in vivo imaging on tumor and ischemia mouse models. Our results demonstrated that the nanoparticles can specifically accumulate at the tumor and ischemic areas and be detected by both imaging modalities. Moreover, this dual-modality imaging strategy exhibited superior advantages for a precise diagnosis in different scenarios. The new nanoprobe with the dual-modality imaging approach holds great potential for diagnosis and stage classification of tumor and ischemia related diseases.Photoacoustic imaging and fluorescence molecular imaging are emerging as important research tools for biomedical studies. Photoacoustic imaging offers both strong optical absorption contrast and high ultrasonic resolution, and fluorescence molecular imaging provides excellent superficial resolution, high sensitivity, high throughput, and the ability for real-time imaging. Therefore, combining the imaging information of both modalities can provide comprehensive in vivo physiological and pathological information. However, currently there are limited probes available that can realize both fluorescence and photoacoustic imaging, and advanced biomedical applications for applying this dual-modality imaging approach remain underexplored. In this study, we developed a dual-modality photoacoustic-fluorescence imaging nanoprobe, ICG-loaded Au@SiO2, which was uniquely designed, consisting of gold nanorod cores and indocyanine green with silica shell spacer layers to overcome fluorophore quenching. This nanoprobe was examined by both PAI and FMI for in vivo imaging on tumor and ischemia mouse models. Our results demonstrated that the nanoparticles can specifically accumulate at the tumor and ischemic areas and be detected by both imaging modalities. Moreover, this dual-modality imaging strategy exhibited superior advantages for a precise diagnosis in different scenarios. The new nanoprobe with the dual-modality imaging approach holds great potential for diagnosis and stage classification of tumor and ischemia related diseases. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr03809c
Weissman, Jake; Johnson, James D; Anderson, Melissa; Hollender, Lars; Huson, Tim; Paranjpe, Avina; Patel, Shanon; Cohenca, Nestor
2015-11-01
Cone-beam computed tomographic (CBCT) imaging is a valuable adjunct to endodontic practice. Among the endodontic applications of CBCT imaging, it aids in the diagnosis of apical periodontitis, often in cases in which there is no evidence of pathosis identified by conventional imaging. The purpose of this study was to correlate the presence of apical periodontitis of teeth evaluated with 2-dimensional periapical (PA) radiographs and 3-dimensional CBCT volumes with clinical signs and symptoms. Clinical records were reviewed from patients examined at the graduate endodontics clinic. The examination included clinical examination, sensibility tests, PA radiographs, and limited field-of-view CBCT scans. Of 498 cases, 67 fulfilled the inclusion criteria and were evaluated for apical periodontitis and symptomology. CBCT slices and PA radiographs were evaluated by 2 board-certified endodontists and a board-certified oral and maxillofacial radiologist for the presence of apical periodontitis. Thirty eight of 67 teeth showed the presence of apical radiolucencies on PA radiographs and on CBCT imaging, whereas 14 teeth had no evidence of apical radiolucencies on either imaging modality. Fifteen cases showed the presence of apical radiolucencies visible on CBCT imaging that were not visible on PA radiographic images. The presence of apical radiolucencies on CBCT slices and PA radiographic images was correlated with clinical signs and symptoms, including the chief complaint. This research has important implications to prevent overexposure to radiation and to provide treatment for those patients with persistent symptoms lacking proper diagnosis based on conventional (2D) radiographs. Copyright © 2015. Published by Elsevier Inc.
The role of body image in prenatal and postpartum depression: a critical review of the literature.
Silveira, Marushka L; Ertel, Karen A; Dole, Nancy; Chasan-Taber, Lisa
2015-06-01
Maternal depression increases risk of adverse perinatal outcomes, and recent evidence suggests that body image may play an important role in depression. This systematic review identifies studies of body image and perinatal depression with the goal of elucidating the complex role that body image plays in prenatal and postpartum depression, improving measurement, and informing next steps in research. We conducted a literature search of the PubMed database (1996-2014) for English language studies of (1) depression, (2) body image, and (3) pregnancy or postpartum. In total, 19 studies matched these criteria. Cross-sectional studies consistently found a positive association between body image dissatisfaction and perinatal depression. Prospective cohort studies found that body image dissatisfaction predicted incident prenatal and postpartum depression; findings were consistent across different aspects of body image and various pregnancy and postpartum time periods. Prospective studies that examined the reverse association found that depression influenced the onset of some aspects of body image dissatisfaction during pregnancy, but few evaluated the postpartum onset of body image dissatisfaction. The majority of studies found that body image dissatisfaction is consistently but weakly associated with the onset of prenatal and postpartum depression. Findings were less consistent for the association between perinatal depression and subsequent body image dissatisfaction. While published studies provide a foundation for understanding these issues, methodologically rigorous studies that capture the perinatal variation in depression and body image via instruments validated in pregnant women, consistently adjust for important confounders, and include ethnically diverse populations will further elucidate this association.
[The radiologist physician in major trauma evaluation].
Motta-Ramírez, Gaspar Alberto
2016-01-01
Trauma is the most common cause of death in young adults. A multidisciplinary trauma team consists of at least a surgical team, an anesthesiology team, radiologic team, and an emergency department team. Recognize the integration of multidisciplinary medical team in managing the trauma patient and which must include the radiologist physician responsible for the institutional approach to the systematization of the trauma patient regarding any radiological and imaging study with emphasis on the FAST (del inglés, Focused Assessment with Sonography in Trauma)/USTA, Whole body computed tomography. Ultrasound is a cross-sectional method available for use in patients with major trauma. Whole-body multidetector computed tomography became the imaging modality of choice in the late 1990s. In patients with major trauma, examination FAST often is the initial imaging examination, extended to extraabdominal regions. Patients who have multitrauma from blunt mechanisms often require multiple diagnostic examinations, including Computed Tomography imaging of the torso as well as abdominopelvic Computed Tomography angiography. Multiphasic Whole-body trauma imaging is feasible, helps detect clinically relevant vascular injuries, and results in diagnostic image quality in the majority of patients. Computed Tomography has gained importance in the early diagnostic phase of trauma care in the emergency room. With a single continuous acquisition, whole-body computed tomography angiography is able to demonstrate all potentially injured organs, as well as vascular and bone structures, from the circle of Willis to the symphysis pubis.
Eller, Achim; Wuest, Wolfgang; Scharf, Michael; Brand, Michael; Achenbach, Stephan; Uder, Michael; Lell, Michael M
2013-12-01
To evaluate an automated attenuation-based kV-selection in computed tomography of the chest in respect to radiation dose and image quality, compared to a standard 120 kV protocol. 104 patients were examined using a 128-slice scanner. Fifty examinations (58 ± 15 years, study group) were performed using the automated adaption of tube potential (100-140 kV), based on the attenuation profile of the scout scan, 54 examinations (62 ± 14 years, control group) with fixed 120 kV. Estimated CT dose index (CTDI) of the software-proposed setting was compared with a 120 kV protocol. After the scan CTDI volume (CTDIvol) and dose length product (DLP) were recorded. Image quality was assessed by region of interest (ROI) measurements, subjective image quality by two observers with a 4-point scale (3--excellent, 0--not diagnostic). The algorithm selected 100 kV in 78% and 120 kV in 22%. Overall CTDIvol reduction was 26.6% (34% in 100 kV) overall DLP reduction was 22.8% (32.1% in 100 kV) (all p<0.001). Subjective image quality was excellent in both groups. The attenuation based kV-selection algorithm enables relevant dose reduction (~27%) in chest-CT while keeping image quality parameters at high levels. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
The clinical diagnosis of splenomegaly.
Yang, J. C.; Rickman, L. S.; Bosser, S. K.
1991-01-01
Assessing for the presence of splenomegaly is an important component of the physical examination. Although several methods of palpation and percussion of the spleen have been described, until recently they have not been validated by noninvasive imaging techniques such as ultrasonography, radionuclide scanning, and computed tomography that offer objective means to assess splenomegaly. We review the literature comparing various physical examination techniques with noninvasive imaging modalities and conclude that palpation and percussion of the spleen are complementary but frequently insensitive and that further studies are needed to evaluate the efficacy of specific diagnostic methods. PMID:1877230
Adamczewski, Zbigniew; Brzeziński, Jan; Lewiński, Andrzej
2010-01-01
Purpose The aim of the study was to evaluate the functionality of vocal folds (VF) by real-time, high-resolution ultrasonography (US) and to correlate the imaged features to results of laryngological examination (LE). Methods The study group comprised 50 patients (41 females and nine males), qualified to thyroidectomy. All the patients had LE and US examination before and 2 days, 2 months, and 3 months after the surgery. We used high-resolution US imaging to identify VFs and, subsequently, a pulsed Doppler and Doppler gate to quantify the tissue displacement velocity in the vibrating VF section. Results LE revealed unilateral VF paralysis in two patients. VF dysfunction was diagnosed in other four subjects. In simultaneously performed US examination, changes in VF displacement velocity (VFDV) were observed in ten patients. In two subjects, VFDV was below 30 cm/s— patients with VF paralysis, diagnosed in LE. In a further eight cases, we observed VFDV decrease by 50%, comparing to preoperative values. Both US-imaging and LE, performed after the 3-month follow-up, confirmed the transitional character of the above-mentioned pathologies. Conclusions US imaging of the VFs correlated with LE results, while being a minimally invasive, easily reproducible, and inexpensive method of examining VF functionality. Thanks to many recording options, it may soon become a perfect tool for an early identification of postoperative VF dysfunction with its later monitoring. To our knowledge, it is the first application of US and Doppler gate modes for VFDF quantification; however, an analysis on a larger group of patients is necessary to standardize the technique. PMID:20640934
Martín Martín, Gonzalo; García Armengol, Juan; Roig Vila, José Vicente; García Coret, María José; Martínez Sanjuán, Vicente; Almela Notari, Pedro; Mínguez Pérez, Miguel
2012-05-01
The aetiological diagnosis of obstructive defaecation syndrome (ODS) requires, among others, imaging tests. The purpose of this study is to descriptively analyse and compare the findings of dynamic pelvic magnetic resonance imaging (DPMRI) with the clinical examinations in patients with ODS. A prospective comparative study was made between the physical examination and the DPMRI, with a descriptive analysis of the results. A total of 30 patients were included (2 males and 28 females), with a median age of 60 (range 23-76) years, with symptoms of ODS. An anamnesis and detailed physical examination and a DPMRI were performed on all of them. Functional (anismus) and morphological changes (rectocele, enterocele, intussusception, etc.), were analysed. The physical examination did not detect anomalies in 6 (20%) patients. A rectocele was diagnosed in 21 (70%) of the cases, and 2 (6.7%) a rectal mucosal prolapse. The DPMRI showed evidence of pelvic floor laxity in 22 (73.3%) cases, an enterocele in 4 (13.3%), a sigmoidocele in 2 (6.7%), intussusception in 8 (26.7%), rectal mucosal prolapse in 4 (13.3%), anismus in 3 (10%), and a cystocele in 4 (13.3%). The rectocele was the most frequent diagnosis, being given in 26 (86.6%) patients. Magnetic resonance imaging provides an overall pelvic assessment with good definition of the tissues, and does not use ionising radiation, is well tolerated, and provides us with complementary information to arrive at the diagnosis, and establish the best treatment for ODS. Larger studies comparing videodefaecography (VD), currently considered the Gold Standard technique, are needed to be able to demonstrate whether it is superior or not to DPMRI. Copyright © 2011 AEC. Published by Elsevier Espana. All rights reserved.
Use of Ultrasound Elastography in the Assessment of the Musculoskeletal System.
Paluch, Łukasz; Nawrocka-Laskus, Ewa; Wieczorek, Janusz; Mruk, Bartosz; Frel, Małgorzata; Walecki, Jerzy
2016-01-01
This article presents possible applications of ultrasound elastography in musculoskeletal imaging based on the available literature, as well as the possibility of extending indications for the use of elastography in the future. Ultrasound elastography (EUS) is a new method that shows structural changes in tissues following application of physical stress. Elastography techniques have been widely used to assess muscles and tendons in vitro since the early parts of the twentieth century. Only recently with the advent of new technology and creation of highly specialized ultrasound devices, has elastography gained widespread use in numerous applications. The authors performed a search of the Medline/PubMed databases for original research and reviewed publications on the application of ultrasound elastography for musculoskeletal imaging. All publications demonstrate possible uses of ultrasound elastography in examinations of the musculoskeletal system. The most widely studied areas include the muscles, tendons and rheumatic diseases. There are also reports on the employment in vessel imaging. The main limitation of elastography as a technique is above all the variability of applied pressure during imaging, which is operator-dependent. It would therefore be reasonable to provide clear guidelines on the technique applied, as well as clear indications for performing the test. It is important to develop methods for creating artifact-free, closed-loop, compression-decompression cycles. The main advantages include cost-effectiveness, short duration of the study, non-invasive nature of the procedure, as well as a potentially broader clinical availability. There are no clear guidelines with regard to indications as well as examination techniques. Ultrasound elastography is a new and still poorly researched method. We conclude, however, that it can be widely used in the examinations of musculoskeletal system. Therefore, it is necessary to conduct large, multi-center studies to determine the methodology, indications and technique of examination.
Probes and monitors for the study of solidification of molten semiconductors
NASA Technical Reports Server (NTRS)
Sadoway, D. R.
1986-01-01
The purpose is to examine solidification in the LiCl-KCl system to determine if phenomena such as solute rejection can be obseved by laser schlieren imaging. Molten salts have attributes that make them attractive as physical models in solidification studies. With optical techniques of investigation such as schlieren imaging, it is possible to study fluid flow phenomena in molten salts and to watch the trajectory of the solid-liquid interface.
NASA Technical Reports Server (NTRS)
Selzer, Robert H. (Inventor); Hodis, Howard N. (Inventor)
2006-01-01
High resolution B-mode ultrasound images of the common carotid artery are obtained with an ultrasound transducer using a standardized methodology. Subjects are supine with the head counter-rotated 45 degrees using a head pillow. The jugular vein and carotid artery are located and positioned in a vertical stacked orientation. The transducer is rotated 90 degrees around the centerline of the transverse image of the stacked structure to obtain a longitudinal image while maintaining the vessels in a stacked position. A computerized methodology assists operators to accurately replicate images obtained over several spaced-apart examinations. The methodology utilizes a split-screen display in which the arterial ultrasound image from an earlier examination is displayed on one side of the screen while a real-time live ultrasound image from a current examination is displayed next to the earlier image on the opposite side of the screen. By viewing both images, whether simultaneously or alternately, while manually adjusting the ultrasound transducer, an operator is able to bring into view the real-time image that best matches a selected image from the earlier ultrasound examination. Utilizing this methodology, measurement of vascular dimensions such as carotid arterial IMT and diameter, the coefficient of variation is substantially reduced to values approximating from about 1.0% to about 1.25%. All images contain anatomical landmarks for reproducing probe angulation, including visualization of the carotid bulb, stacking of the jugular vein above the carotid artery, and initial instrumentation settings, used at a baseline measurement are maintained during all follow-up examinations.
Optimising magnetic resonance image quality of the ear in healthy dogs.
Wolf, Davina; Lüpke, Matthias; Wefstaedt, Patrick; Klopmann, Thilo; Nolte, Ingo; Seifert, Hermann
2011-03-01
The aim of this study was to develop an examination protocol for magnetic resonance imaging, in order to display diagnostically important information of the canine middle and inner ear. To ensure that this protocol could also be used as a basis for determining pathological changes, the anatomical structures of the ear were presented in detail. To minimise stress through anaesthesia in live animals, preliminary examinations were carried out on four dog cadavers. During these initial examinations, three-dimensional (3D) sequences proved to be superior to two-dimensional ones. Therefore, only 3D sequences were applied for the main examinations performed on six clinically healthy Beagles. The anonymised MR images were rated by three experienced reviewers using a five-point scale. The most valuable sequence was a T2-weighted CISS sequence (TR = 16.7 ms, TE = 8.08 ms). This sequence proved to be most suitable for illustrating the inner ear structures and enabled good tissue contrasts. The sequence ranked second best was also a T2-weighted DESS sequence (TR = 19 ms, TE = 6 ms), allowing the imaging of the tympanic cavity and enabling 3D reconstruction due to its isotropic voxels. Due to low contrast and strong noise, the other sequences (TSE, FISP, MP RAGE) were not suitable for anatomical illustration of the middle and inner ear.
Gigapixel photography for skin cancer surveillance: a novel alternative to total-body photography.
Mikailov, Anar; Blechman, Adam
2013-11-01
There is substantial evidence supporting the use of cutaneous imaging in combination with standard total-body skin examinations for early detection and treatment of melanoma. In the last 2 decades, total-body photography (TBP) has been widely used in combination with standard total-body skin examinations for active skin cancer surveillance with proven clinical utility; however, the groundbreaking image detail provided by gigapixel photography (GP) could improve dermatologists' ability to monitor suspicious lesions and therefore could serve a critical role in supplementing traditional total-body skin examinations for skin cancer surveillance. Although it has been successfully implemented in other fields, future studies are required to determine the effectiveness of GP in dermatology.
Fang, Su-Ying; Chang, Hong-Tai; Shu, Bih-Ching
2015-12-01
The aims of the study were the following: (1) to understand the relationship between women's perceptions of empathy from their partners and their depressive symptoms and body image and (2) to examine the moderating effects of women's perceptions of empathy from their partners on the relationship between body image and depressive symptoms. A cross-sectional and correlational design was used, in which a convenience sample of 151 women who completed surgery and the necessary chemotherapy/radiotherapy were recruited from southern Taiwan. A structured questionnaire including the Other Dyadic Perspective-Taking Scale, the Body Image Scale, and the Center for Epidemiologic Studies Depression scale were administered. Hierarchical regression was used to examine the moderating effects of empathy from partners between the women's body image and their level of depressive symptoms. The results showed significant relationships between empathy from a partner and depressive symptoms (p < 0.001). However, there was no significant relationship between empathy from a partner and body image (p > 0.05). The moderating effect of empathy from a partner on the relationship between body image and depressive symptoms was also significant (p < 0.01). The more empathy women perceived from partners, the fewer depressive symptoms women reported. Empathy from a partner could moderate the impact of body image changes on depressive symptoms. Women's depressive symptoms, resulting from a change in body image after breast cancer surgery, might be minimized if they perceived greater empathy from their partners. Copyright © 2015 John Wiley & Sons, Ltd.
Guagliano, Rosanna; Barillà, Donatella; Bertone, Chiara; Maffia, Anna; Periti, Francesca; Spallone, Laura; Anselmetti, Giovanni; Giacosa, Elisabetta; Stronati, Mauro; Tinelli, Carmine; Bianchi, Paolo Emilio
2013-01-01
To evaluate accuracy and inter-rater reliability of RetCam fundus images and digital camera fluorangioscopic images in acute retinopathy of prematurity (ROP) by comparing diagnoses given by trainee ophthalmologists with those provided by expert ophthalmologists. This is a multicenter retrospective observational study of diagnostic data from 48 eyes of 24 premature infants with classical ROP, stage II, as evaluated by RetCam 3 and fluorescein angiography (FA). Average gestational age was 25.4 weeks, average weight 804.7 g. A staging grid (with ocular fundus divided into 3 concentric zones) and 24 15° sectors centered around the optic papilla were superimposed on 360° retina photomontages (Photoshop) made from RetCam and FA images. Non expert vs expert diagnosis agreement was measured for each sector by means of Cohen kappa (Fleiss, 1981). A high degree of concordance was found. Inter-rater agreement between expert and non expert interpretations of retinal photomontages was greater for fluorangiographic images than for RetCam images, with κ = 0.61-1 for 120/152 (78.9%) sectors examined on the RetCam images and κ = 0.61-1 for 168/198 (84.8%) sectors examined on the FA images. The FA images appear to be easier to interpret than RetCam images, both by expert and non expert ophthalmologists. The results confirm that FA is a good examination technique with a high degree of reliability, even where trainee practitioners are involved. This suggests that retinopathy management can be improved by entrusting diagnostic responsibilities to trainee ophthalmologists, in order to extend access to correct diagnosis, recognition of threshold lesions, and prompt treatment.
Wada, Yoichi; Hara, Takanori; Miyati, Tosiaki
2008-02-20
Many methods of measuring contrast-to-noise ratio (CNR) in magnetic resonance imaging (MRI) have been proposed. However, it is not clear which method is best for evaluating clinical or phantom images. In this study we examined the characteristics of the methods of evaluation proposed in the past, and we proposed new CNR evaluation method that improved noise evaluation. We examined the relationship of theoretical CNR value and measurement value when measurement sensitivity was changed. We measured the relationship between number of signal averaged (NSA) and value of CNR. The CNR value changed greatly according to where noise was measured. The measuring method that we proposed in this study was superior for the following reasons: the measurement point of noise and signal are the same; the influence of the low frequency element is slight; and the correlation of measurements and theoretical value is high. The method that we proposed in this study is useful for evaluating phantom images.
Nakagawa, Junichiro; Tasaki, Osamu; Watanabe, Yoshiyuki; Azuma, Takeo; Ohnishi, Mitsuo; Ukai, Isao; Tahara, Kenichi; Ogura, Hiroshi; Kuwagata, Yasuyuki; Hamasaki, Toshimitsu; Shimazu, Takeshi
2013-01-01
Electrocardiogram-gated imaging combined with multi-detector row computed tomography (MDCT) has reduced cardiac motion artifacts, but it was not practical in the emergency setting. The purpose of this study was to evaluate the ability of a high-pitch, 128-slice dual-source CT (DSCT) scanner to reduce motion artifacts in patients admitted to the emergency room. This study comprised 100 patients suspected of having thoracic aorta lesions. We examined 47 patients with the 128-slice DSCT scanner (DSCT group), and 53 patients were examined with a 64-slice MDCT scanner (MDCT group). Six anatomic areas in the thoracic aorta were evaluated. Computed tomography images in the DSCT group were distinct, and significant differences were observed in images of all areas between the 2 groups except for the descending aorta. The high-pitch DSCT scanner can reduce motion artifacts of the thoracic aorta and enable radiological diagnosis even in patients with tachycardia and without breath hold.
Precision of computer vision systems for real-time inspection of contact wire wear in railways
NASA Astrophysics Data System (ADS)
Borromeo, Susana; Aparicio, Jose L.
2005-02-01
This paper is oriented to study techniques to improve the precision of the systems for wear measurement of contact wire in the railways. The problematic of wear measurement characterized by some important determining factors like rate of sampling and auscultation conditions is studied in detail. The different solutions to resolve the problematic successfully are examined. Issues related to image acquisition and image processing are discussed. Type of illumination and sensors employed, image processing hardware and image processing algorithms are some topics studied. Once analyzed each one factor which have influence on the precision of the measurement system, there are proposed an assembly of solutions that allow to optimize the conditions under which the inspection can be carried out.
The pupil's response to affective pictures: Role of image duration, habituation, and viewing mode
O'Farrell, Katherine R.; Burley, Daniel; Erichsen, Jonathan T.; Newton, Naomi V.; Gray, Nicola S.
2016-01-01
Abstract The pupil has been shown to be sensitive to the emotional content of stimuli. We examined this phenomenon by comparing fearful and neutral images carefully matched in the domains of luminance, image contrast, image color, and complexity of content. The pupil was more dilated after viewing affective pictures, and this effect was (a) shown to be independent of the presentation time of the images (from 100–3,000 ms), (b) not diminished by repeated presentations of the images, and (c) not affected by actively naming the emotion of the stimuli in comparison to passive viewing. Our results show that the emotional modulation of the pupil is present over a range of variables that typically vary from study to study (image duration, number of trials, free viewing vs. task), and encourages the use of pupillometry as a measure of emotional processing in populations where alternative techniques may not be appropriate. PMID:27172997
Kindrat, Shauna
2007-01-01
Little is known about perceptions of body image in women diagnosed with relapsing remitting multiple sclerosis (RRMS). This descriptive correlational study was conducted to describe how women perceive their body image while living with RRMS, and to examine a potential relationship between body image and depression in women who have RRMS. A convenience sample of 30 women from a western Canadian multiple sclerosis (MS) clinic completed a demographic questionnaire, the Body-Image Ideals Questionnaire (BIQ), and the Beck Depression Inventory Short Form (BDI-SF). Body image and depression scores were highly correlated (r = 0.814, p = 0.01) indicating that a more positive body image was associated with less depression. The findings of this study suggest that there are important psychological aspects to which clinicians might need to attend when working with women who have RRMS. However, further research needs to be done in this area.
May, Matthias Stefan; Bruegel, Joscha; Brand, Michael; Wiesmueller, Marco; Krauss, Bernhard; Allmendinger, Thomas; Uder, Michael; Wuest, Wolfgang
2017-09-01
The aim of this study was to intra-individually compare the image quality obtained by dual-source, dual-energy (DSDE) computed tomography (CT) examinations and different virtual monoenergetic reconstructions to a low single-energy (SE) scan. Third-generation DSDE-CT was performed in 49 patients with histologically proven malignant disease of the head and neck region. Weighted average images (WAIs) and virtual monoenergetic images (VMIs) for low (40 and 60 keV) and high (120 and 190 keV) energies were reconstructed. A second scan aligned to the jaw, covering the oral cavity, was performed for every patient to reduce artifacts caused by dental hardware using a SE-CT protocol with 70-kV tube voltages and matching radiation dose settings. Objective image quality was evaluated by calculating contrast-to-noise ratios. Subjective image quality was evaluated by experienced radiologists. Highest contrast-to-noise ratios for vessel and tumor attenuation were obtained in 40-keV VMI (all P < 0.05). Comparable objective results were found in 60-keV VMI, WAI, and the 70-kV SE examinations. Overall subjective image quality was also highest for 40-keV, but differences to 60-keV VMI, WAI, and 70-kV SE were nonsignificant (all P > 0.05). High kiloelectron volt VMIs reduce metal artifacts with only limited diagnostic impact because of insufficiency in case of severe dental hardware. CTDIvol did not differ significantly between both examination protocols (DSDE: 18.6 mGy; 70-kV SE: 19.4 mGy; P = 0.10). High overall image quality for tumor delineation in head and neck imaging were obtained with 40-keV VMI. However, 70-kV SE examinations are an alternative and modified projections aligned to the jaw are recommended in case of severe artifacts caused by dental hardware.
The impact of image-size manipulation and sugar content on children's cereal consumption.
Neyens, E; Aerts, G; Smits, T
2015-12-01
Previous studies have demonstrated that portion sizes and food energy-density influence children's eating behavior. However, the potential effects of front-of-pack image-sizes of serving suggestions and sugar content have not been tested. Using a mixed experimental design among young children, this study examines the effects of image-size manipulation and sugar content on cereal and milk consumption. Children poured and consumed significantly more cereal and drank significantly more milk when exposed to a larger sized image of serving suggestion as compared to a smaller image-size. Sugar content showed no main effects. Nevertheless, cereal consumption only differed significantly between small and large image-sizes when sugar content was low. An advantage of this study was the mundane setting in which the data were collected: a school's dining room instead of an artificial lab. Future studies should include a control condition, with children eating by themselves to reflect an even more natural context. Copyright © 2015 Elsevier Ltd. All rights reserved.
Mukherjee, Sahana; Salter, Phia S.; Molina, Ludwin E.
2015-01-01
The present research draws upon a cultural psychological perspective to consider how psychological phenomena are grounded in socio-cultural contexts. Specifically, we examine the association between representations of history at Ellis Island Immigration Museum and identity-relevant concerns. Pilot study participants (N = 13) took a total of 114 photographs of exhibits that they considered as most important in the museum. Results indicate that a majority of the photographs reflected neutral themes (n = 81), followed by nation-glorifying images (n = 24), and then critical themes that highlight injustices and barriers faced by immigrants (n = 9). Study 1 examines whether there is a preference for glorifying images, and if that preference is related to cultural-assimilationist conceptions of national identity (i.e., defining American identity in dominant group standards). We exposed a new sample of participants (N = 119) to photographs reflecting all three themes. Results indicate that participants expressed greater liking for glorifying images, followed by neutral images, and critical images. National identity moderated within-subject variation in liking scores. Study 2 included 35 visitors who completed a survey before engaging with the museum or after their visit. Results indicate that participants who had completed their visit, compared to participants who had not entered the museum, reported (i) higher endorsement of cultural-assimilationist identity, and (ii) increased support for exclusive immigration policies. Study 3 exposed participants (N = 257) to glorifying, critical, or neutral images. Results indicate that participants who were exposed to glorifying images, especially those endorsing cultural-assimilationist identity, demonstrate decreased perception of current-day racial injustice, and increased ethnocentric enforcement bias. We discuss how engagement with privileged narratives may serve dominant group ends and reproduce systems of privilege. PMID:26074846
NASA Astrophysics Data System (ADS)
Livings, R. A.; Dayal, V.; Barnard, D. J.; Hsu, D. K.
2012-05-01
Ceramic tiles are the main ingredient of a multi-material, multi-layered composite being considered for the modernization of tank armors. The high stiffness, low attenuation, and precise dimensions of these uniform tiles make them remarkable resonators when driven to vibrate. Defects in the tile, during manufacture or after usage, are expected to change the resonance frequencies and resonance images of the tile. The comparison of the resonance frequencies and resonance images of a pristine tile/lay-up to a defective tile/lay-up will thus be a quantitative damage metric. By examining the vibrational behavior of these tiles and the composite lay-up with Finite Element Modeling and analytical plate vibration equations, the development of a new Nondestructive Evaluation technique is possible. This study examines the development of the Air-Coupled Ultrasonic Resonance Imaging technique as applied to a hexagonal ceramic tile and a multi-material, multi-layered composite.
Frederick, David A; Sandhu, Gaganjyot; Scott, Terri; Akbari, Yasmin
2016-06-01
Body image activists have proposed adding disclaimer labels to digitally altered media as a way to promote positive body image. Another approach advocated by activists is to alter advertisements through subvertising (adding social commentary to the image to undermine the message of the advertisement). We examined if body image could be enhanced by attaching Photoshop disclaimers or subvertising to thin-ideal media images of swimsuit models. In Study 1 (N=1268), adult women exposed to disclaimers or subvertising did not report higher body state satisfaction or lower drive for thinness than women exposed to unaltered images. In Study 2 (N=820), adult women who were exposed to disclaimers or subvertising did not report higher state body satisfaction or lower state social appearance comparisons than women exposed to unaltered images or to no images. These results raise questions about the effectiveness of disclaimers and subvertising for promoting body satisfaction. Copyright © 2016 Elsevier Ltd. All rights reserved.
Ruuska, J; Kaltiala-Heino, R; Rantanen, P; Koivisto, A M
2005-06-01
Body image dissatisfaction is as well a risk factor for eating disorders (ED) and a central feature of ED. The exact nature of body image in adolescent ED is still debated. This study examined attitudinal body image in adolescent anorexia nervosa (AN) and bulimia nervosa (BN), and the association of age, maturational timing, duration of eating disorder, actual weight and general psychological distress with the attitudinal body image in ED. The study group consisted of an outpatient clinical sample of adolescents attending for assessment because of eating disorders. The attitudinal body image of 57 adolescents (girls) aged 14-21 years was studied at the beginning of the treatment. The attitudes to body shape, body size, appearance, tone and femininity were studied by a Likert format scale and by the body dissatisfaction (BD) and drive for thinness scales (DT) from EDI-2 inventory. Bulimics reported more body image dissatisfaction than anorectics. In multivariate analyses BN and higher general psychological distress had strong associations with body image dissatisfaction. Longer duration of ED and earlier menarche were also associated with negative body image. Attitudinal body image differs between adolescent AN and BN. The psychological distress has a great impact on body image in ED, which should be taken into account in assessment and in treatment interventions.
ERIC Educational Resources Information Center
Yager, Zali; O'Dea, Jennifer
2010-01-01
This study examined the impact of two interventions on body image, eating disorder risk and excessive exercise among 170 (65% female) trainee health education and physical education (HE & PE) teachers of mean (standard deviation) age 21.6 (2.3) who were considered an "at-risk" population for poor body image and eating disorders. In the first year…
McCrea, C; Neil, W J; Flanigan, J W; Summerfield, A B
1988-08-01
In this study a new modified videosystem, designed for measuring body-image, was evaluated alongside the major size-estimation measure, namely, the visual size-estimation apparatus. The advantages afforded by a videosystem which allows independent adjustment of size and height/width proportions were highlighted, and its validity and reliability were examined, based on estimates made by obese, normal weight, and pregnant groups.
Images and Ideals: Counselling Women and Girls in a "Thin-is-in" Culture
ERIC Educational Resources Information Center
Saraceni, Reana; Russell-Mayhew, Shelly
2007-01-01
Two well-cited studies (Garner, Garfinkel, Schwartz & Thompson, 1980; Wiseman, Gray, Mosimann, & Ahrens, 1992) examined the changing body shape of Playboy centrefolds from 1959 to 1988 and noted that their body weights were significantly lower than those of the average female. The current study updates and examines changes in body measurements and…
Radiologic Assessment of Patellofemoral Pain in the Athlete
Endo, Yoshimi; Stein, Beth E. Shubin; Potter, Hollis G.
2011-01-01
Context: Although disorders of the patellofemoral joint are common in the athlete, their management can be challenging and require a thorough physical examination and radiologic evaluation, including advanced magnetic resonance imaging techniques. Evidence Acquisition: Relevant articles were searched under OVID and MEDLINE (1968 to 2010) using the keywords patellofemoral joint, patellofemoral pain or patella and radiography, imaging, or magnetic resonance imaging, and the referenced sources were reviewed for additional articles. The quality and validity of the studies were assessed on the basis of careful analysis of the materials and methods before their inclusion in this article. Results: Physical examination and imaging evaluation including standard radiographs are crucial in identifying evidence of malalignment or instability. Magnetic resonance imaging provides valuable information about concomitant soft tissue injuries to the medial stabilizers as well as injuries to the articular cartilage, including chondral shears and osteochondral fractures. Quantitative magnetic resonance imaging assessing the ultrastructure of cartilage has shown high correlation with histology and may be useful for timing surgery. Conclusions: Evaluation of patellofemoral disorders is complex and requires a comprehensive assessment. Recent advancements in imaging have made possible a more precise evaluation of the individual anatomy of the patient, addressing issues of malalignment, instability, and underlying cartilage damage. PMID:23016009
Multicenter study of subjective acceptance during magnetic resonance imaging at 7 and 9.4 T.
Rauschenberg, Jaane; Nagel, Armin M; Ladd, Susanne C; Theysohn, Jens M; Ladd, Mark E; Möller, Harald E; Trampel, Robert; Turner, Robert; Pohmann, Rolf; Scheffler, Klaus; Brechmann, André; Stadler, Jörg; Felder, Jörg; Shah, N Jon; Semmler, Wolfhard
2014-05-01
The aims of this study were to investigate the subjective discomfort and sensory side effects during ultrahigh field (UHF) magnetic resonance imaging (MRI) examinations in a large-scale study and to evaluate differences between magnetic resonance (MR) sites. Four MR sites with a 7-T MR system and 2 MR sites with a 9.4-T MR system participated in this multicenter study with a total number of 3457 completed questionnaires on causes of discomfort and sensations during the examination. For a pooled retrospective analysis of the results from the partially different questionnaires, all data were adapted to an answer option with a 4-point scale (0 = no discomfort/side effect, 3 = very unpleasant/very strong sensation). To differentiate effects evoked by the low-frequency time-varying magnetic fields due to movement through the static magnetic field, most questionnaires separated the manifestation of sensory side effects during movement on the patient table from manifestation while lying still in the isocenter. In general, a high acceptance of UHF examinations was found, where in 82% of the completed questionnaires, the subjects stated the examination to be at least tolerable. Although in 7.6% of the questionnaires, subjects felt discomfort during the examination, only 0.9% of the image acquisitions had to be terminated prematurely. No adverse events occurred in any of the examinations. Only 1% of the subjects were unwilling to undergo further UHF MRI examinations. Examination duration was the most complained cause of discomfort, followed by acoustic noise and lying still. All magnetic-field-related sensations were more pronounced when moving the patient table versus the isocenter position (19%/2% of the subjects felt unpleasant vertigo during the moving/stationary state). In general, vertigo was the most often stated sensory side effect and was more pronounced at 9.4 T compared with 7 T. However, the results varied substantially among the different sites. The high levels of subjective acceptance found in this study lead to the conclusion that UHF MRI would be tolerated as a diagnostic tool in clinical practice. For more consistent data ascertainment, we propose a standardized questionnaire for subjective perception monitoring.
Body image and weight control in South Africans 15 years or older: SANHANES-1.
Mchiza, Zandile J; Parker, Whadi-Ah; Makoae, Mokhantso; Sewpaul, Ronel; Kupamupindi, Takura; Labadarios, Demetre
2015-09-30
South African studies have suggested that differences in obesity prevalence between groups may be partly related to differences in body image and body size dissatisfaction. However, there has never been a national study that measured body image and its relationship to weight control in the country. Hence, the main aim of the study was to examine body image in relation to body mass index and weight control in South Africa. A cross-sectional survey and a secondary analyses of data were undertaken for 6 411 South Africans (15+ years) participating in the first South African National Health and Nutrition Examination Survey. Body image was investigated in relation to weight status and attempts to lose or gain weight. Data were analysed using STATA version 11.0. Descriptive statistics are presented as counts (numbers), percentages, means, standard error of means, and 95 % confidence intervals. Any differences in values were considered to be significantly different if the confidence intervals did not overlap. Overall, 84.5 % participants had a largely distorted body image and 45.3 % were highly dissatisfied about their body size. Overweight and obese participants under estimated their body size and desired to be thinner. On the other hand, normal- and under-weight participants over estimated their body size and desired to be fatter. Only 12.1 and 10.1 % of participants attempted to lose or gain weight, respectively, mainly by adjusting dietary intake and physical activity. Body mass index appears to influence body image and weight adjustment in South Africa. South Africans at the extreme ends of the body mass index range have a largely distorted body image and are highly dissatisfied by it. This suggests a need for health education and beneficial weight control strategies to halt the obesity epidemic in the country.
Neish, Ariane S; Blews, David E; Simms, Catherine A; Merritt, Robert K; Spinks, Alice J
2002-03-01
To determine whether criteria for screening patients with sickle cell anemia for stroke established with a nonimaging transcranial Doppler ultrasonographic (US) technique are applicable to studies performed with a transcranial Doppler US imaging technique. One hundred sixty-eight examinations in 66 children were performed for sickle cell stroke screening. Children were examined with nonimaging and imaging transcranial Doppler US techniques on the same day, for a total of 84 paired examinations. The time-averaged maximum mean velocity (V(mean)) and resistive index (RI) were calculated in the middle cerebral arteries, bifurcations of the distal internal carotid arteries, distal internal carotid arteries, anterior cerebral arteries, posterior cerebral arteries, and basilar arteries. The maximum systolic velocity (V(max)) was evaluated in the distal internal carotid arteries and middle cerebral arteries. V(mean), V(max), and RI measurements were subjected to repeated-measures multivariate analysis of covariance, and the Pearson product moment correlation was used for middle cerebral artery velocity, age, and hemoglobin. V(mean) measurements obtained with nonimaging and imaging techniques varied substantially for the bifurcation of the distal internal carotid artery, the posterior cerebral artery, and the basilar artery. Substantial differences were found in RIs for every vessel. Examination time was shorter with the nonimaging technique. V(mean) measurements in the middle cerebral artery, distal internal carotid artery, and anterior cerebral artery did not vary substantially between nonimaging and imaging transcranial Doppler US. RI data did not yield comparable measurements.
Microstructural effects of Ramadan fasting on the brain: a diffusion tensor imaging study.
Bakan, Ayse Ahsen; Yıldız, Seyma; Alkan, Alpay; Yetis, Huseyin; Kurtcan, Serpil; Ilhan, Mahmut Muzaffer
2015-01-01
We aimed to examine whether the brain displays any microstructural changes after a three-week Ramadan fasting period using diffusion tenson imaging. This study included a study and a control group of 25 volunteers each. In the study group, we examined and compared apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values of the participants during (phase 1) and after (phase 2) a period of fasting. The control group included individuals who did not fast. ADC and FA values obtained in phase 1 and phase 2 were compared between the study and control groups. In the study group, ADC values of hypothalamus and, to a lesser extent, of insula were lower in phase 1 compared with phase 2 and the control group. The FA values of amygdala, middle temporal cortex, thalamus and, to a lesser extent, of medial prefrontal cortex were lower in phase 1 compared with phase 2 and the control group. Phase 2 ADC and FA values of the study group were not significantly different compared with the control group at any brain location. A three-week Ramadan fasting period can cause microstructural changes in the brain, and diffusion tensor imaging enables the visualization of these changes. The identification of brain locations where changes occurred in ADC and FA values during fasting can be helpful in diagnostic imaging and understanding the pathophysiology of eating disorders.
Microstructural effects of Ramadan fasting on the brain: a diffusion tensor imaging study
Bakan, Ayse Ahsen; Yıldız, Seyma; Alkan, Alpay; Yetis, Huseyin; Kurtcan, Serpil; Ilhan, Mahmut Muzaffer
2015-01-01
PURPOSE We aimed to examine whether the brain displays any microstructural changes after a three-week Ramadan fasting period using diffusion tenson imaging. METHODS This study included a study and a control group of 25 volunteers each. In the study group, we examined and compared apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values of the participants during (phase 1) and after (phase 2) a period of fasting. The control group included individuals who did not fast. ADC and FA values obtained in phase 1 and phase 2 were compared between the study and control groups. RESULTS In the study group, ADC values of hypothalamus and, to a lesser extent, of insula were lower in phase 1 compared with phase 2 and the control group. The FA values of amygdala, middle temporal cortex, thalamus and, to a lesser extent, of medial prefrontal cortex were lower in phase 1 compared with phase 2 and the control group. Phase 2 ADC and FA values of the study group were not significantly different compared with the control group at any brain location. CONCLUSION A three-week Ramadan fasting period can cause microstructural changes in the brain, and diffusion tensor imaging enables the visualization of these changes. The identification of brain locations where changes occurred in ADC and FA values during fasting can be helpful in diagnostic imaging and understanding the pathophysiology of eating disorders. PMID:25835077
Hausenblas, Heather A; Campbell, Anna; Menzel, Jessie E; Doughty, Jessica; Levine, Michael; Thompson, J Kevin
2013-02-01
Older meta-analyses of the effects of the media's portrayal of the ideal physique have found small effects revealing that exposure to the ideal physique increases body image concerns. These meta-analyses also included correlational, quasi-experimental, and experimental studies, with limited examination of moderators and other relevant outcomes besides body image. We conducted a systematic literature search and identified 33 experimental (i.e., pre and post data for both experimental and control groups) laboratory studies examining the effects of acute exposure to the media's portrayal of the ideal physique on eating disorder symptoms (i.e., body image, positive affect, negative affect, self-esteem, anger, anxiety and depression) and the mechanisms that moderate this effect. Fourteen separate meta-analyses revealed a range of small to moderate effect sizes for change in outcomes from pre to post for both experimental and control groups. Exposure to images of the ideal physique resulted in small effect sizes for increased depression and anger and decreased self-esteem and positive affect. Moderator analyses revealed moderate effect sizes for increased depression and body dissatisfaction among high-risk participants. This meta-analysis makes it clear that media exposure of the ideal physique results in small changes in eating disorder symptoms, particularly with participants at high risk for developing an eating disorder. Further research is needed to examine the longitudinal effects of media exposure of eating disorder symptoms. Copyright © 2012 Elsevier Ltd. All rights reserved.
Schiffman, Eric L; Truelove, Edmond L; Ohrbach, Richard; Anderson, Gary C; John, Mike T; List, Thomas; Look, John O
2010-01-01
The purpose of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Validation Project was to assess the diagnostic validity of this examination protocol. The aim of this article is to provide an overview of the project's methodology, descriptive statistics, and data for the study participant sample. This article also details the development of reliable methods to establish the reference standards for assessing criterion validity of the Axis I RDC/TMD diagnoses. The Axis I reference standards were based on the consensus of two criterion examiners independently performing a comprehensive history, clinical examination, and evaluation of imaging. Intersite reliability was assessed annually for criterion examiners and radiologists. Criterion examination reliability was also assessed within study sites. Study participant demographics were comparable to those of participants in previous studies using the RDC/TMD. Diagnostic agreement of the criterion examiners with each other and with the consensus-based reference standards was excellent with all kappas > or = 0.81, except for osteoarthrosis (moderate agreement, k = 0.53). Intrasite criterion examiner agreement with reference standards was excellent (k > or = 0.95). Intersite reliability of the radiologists for detecting computed tomography-disclosed osteoarthrosis and magnetic resonance imaging-disclosed disc displacement was good to excellent (k = 0.71 and 0.84, respectively). The Validation Project study population was appropriate for assessing the reliability and validity of the RDC/TMD Axis I and II. The reference standards used to assess the validity of Axis I TMD were based on reliable and clinically credible methods.
Mitry, Danny; Peto, Tunde; Hayat, Shabina; Morgan, James E; Khaw, Kay-Tee; Foster, Paul J
2013-01-01
Crowdsourcing is the process of outsourcing numerous tasks to many untrained individuals. Our aim was to assess the performance and repeatability of crowdsourcing for the classification of retinal fundus photography. One hundred retinal fundus photograph images with pre-determined disease criteria were selected by experts from a large cohort study. After reading brief instructions and an example classification, we requested that knowledge workers (KWs) from a crowdsourcing platform classified each image as normal or abnormal with grades of severity. Each image was classified 20 times by different KWs. Four study designs were examined to assess the effect of varying incentive and KW experience in classification accuracy. All study designs were conducted twice to examine repeatability. Performance was assessed by comparing the sensitivity, specificity and area under the receiver operating characteristic curve (AUC). Without restriction on eligible participants, two thousand classifications of 100 images were received in under 24 hours at minimal cost. In trial 1 all study designs had an AUC (95%CI) of 0.701(0.680-0.721) or greater for classification of normal/abnormal. In trial 1, the highest AUC (95%CI) for normal/abnormal classification was 0.757 (0.738-0.776) for KWs with moderate experience. Comparable results were observed in trial 2. In trial 1, between 64-86% of any abnormal image was correctly classified by over half of all KWs. In trial 2, this ranged between 74-97%. Sensitivity was ≥ 96% for normal versus severely abnormal detections across all trials. Sensitivity for normal versus mildly abnormal varied between 61-79% across trials. With minimal training, crowdsourcing represents an accurate, rapid and cost-effective method of retinal image analysis which demonstrates good repeatability. Larger studies with more comprehensive participant training are needed to explore the utility of this compelling technique in large scale medical image analysis.
Larson, David B; Malarik, Remo J; Hall, Seth M; Podberesky, Daniel J
2013-10-01
To evaluate the effect of an automated computed tomography (CT) radiation dose optimization and process control system on the consistency of estimated image noise and size-specific dose estimates (SSDEs) of radiation in CT examinations of the chest, abdomen, and pelvis. This quality improvement project was determined not to constitute human subject research. An automated system was developed to analyze each examination immediately after completion, and to report individual axial-image-level and study-level summary data for patient size, image noise, and SSDE. The system acquired data for 4 months beginning October 1, 2011. Protocol changes were made by using parameters recommended by the prediction application, and 3 months of additional data were acquired. Preimplementation and postimplementation mean image noise and SSDE were compared by using unpaired t tests and F tests. Common-cause variation was differentiated from special-cause variation by using a statistical process control individual chart. A total of 817 CT examinations, 490 acquired before and 327 acquired after the initial protocol changes, were included in the study. Mean patient age and water-equivalent diameter were 12.0 years and 23.0 cm, respectively. The difference between actual and target noise increased from -1.4 to 0.3 HU (P < .01) and the standard deviation decreased from 3.9 to 1.6 HU (P < .01). Mean SSDE decreased from 11.9 to 7.5 mGy, a 37% reduction (P < .01). The process control chart identified several special causes of variation. Implementation of an automated CT radiation dose optimization system led to verifiable simultaneous decrease in image noise variation and SSDE. The automated nature of the system provides the opportunity for consistent CT radiation dose optimization on a broad scale. © RSNA, 2013.
Kameyama, Kyoko Nakao; Kido, Aki; Himoto, Yuki; Moribata, Yusaku; Minamiguchi, Sachiko; Konishi, Ikuo; Togashi, Kaori
2018-06-01
Background Half-Fourier acquisition single-shot turbo spin-echo (HASTE) imaging is now widely used for placental and fetal imaging because of its rapidity and low sensitivity to fetal movement. If placental dysfunction is also predicted by quantitative value obtained from HASTE image, then it might be beneficial for evaluating placental wellbeing. Purpose To ascertain the most suitable magnetic resonance (MR) signal indexes reflecting placental function using HASTE imaging. Material and Methods This retrospective study included 37 consequent patients who had given informed consent to MR imaging (MRI) examinations. All had undergone MRI examinations between February 2014 and June 2015. First, the correlation between T2-relaxation time of normal placenta and gestational age (GA) was examined. Second, correlation between signal intensity ratios (SIRs) using HASTE imaging and placental T2-relaxation time were assessed. The SIRs were calculated using placental signal intensity (SI) relative to the SI of the amniotic fluid, fetal ocular globes, gastric fluid, bladder, maternal psoas major muscles, and abdominal subcutaneous adipose tissue. Results Among the 37 patients, the correlation between T2-relaxation time of the 25 normal placentas and GA showed a moderately strong correlation (Spearman rho = -0.447, P = 0.0250). The most significant correlation with placental T2-relaxation time was observed with the placental SIR relative to the maternal psoas major muscles (SIR pl./psoas muscle ) (Spearman rho = -0.531, P = 0.0007). Conclusion This study revealed that SIR pl./psoas muscle showed the best correlation to placental T2-relaxation time. Results show that SIR pl./psoas muscle might be optimal as a clinically available quantitative index of placental function.
Fischbach, Katharina; Kosiek, Otrud; Friebe, Björn; Wybranski, Christian; Schnackenburg, Bernhard; Schmeisser, Alexander; Smid, Jan; Ricke, Jens; Pech, Maciej
2017-01-01
Cardiac magnetic resonance imaging (cMRI) has become the non-invasive reference standard for the evaluation of cardiac function and viability. The introduction of open, high-field, 1.0T (HFO) MR scanners offers advantages for examinations of obese, claustrophobic and paediatric patients.The aim of our study was to compare standard cMRI sequences from an HFO scanner and those from a cylindrical, 1.5T MR system. Fifteen volunteers underwent cMRI both in an open HFO and in a cylindrical MR system. The protocol consisted of cine and unenhanced tissue sequences. The signal-to-noise ratio (SNR) for each sequence and blood-myocardium contrast for the cine sequences were assessed. Image quality and artefacts were rated. The location and number of non-diagnostic segments was determined. Volunteers' tolerance to examinations in both scanners was investigated. SNR was significantly lower in the HFO scanner (all p<0.001). However, the contrast of the cine sequence was significantly higher in the HFO platform compared to the 1.5T MR scanner (0.685±0.41 vs. 0.611±0.54; p<0.001). Image quality was comparable for all sequences (all p>0.05). Overall, only few non-diagnostic myocardial segments were recorded: 6/960 (0.6%) by the HFO and 17/960 (1.8%) segments by the cylindrical system. The volunteers expressed a preference for the open MR system (p<0.01). Standard cardiac MRI sequences in an HFO platform offer a high image quality that is comparable to the quality of images acquired in a cylindrical 1.5T MR scanner. An open scanner design may potentially improve tolerance of cardiac MRI and therefore allow to examine an even broader patient spectrum.
Battaglia, Patrick J; Mattox, Ross; Winchester, Brett; Kettner, Norman W
The primary aim of this study was to determine the reliability of diagnostic ultrasound imaging for select intrinsic foot muscles using both non-weight-bearing and weight-bearing postures. Our secondary aim was to describe the change in muscle cross-sectional area (CSA) and dorsoplantar thickness when bearing weight. An ultrasound examination was performed with a linear ultrasound transducer operating between 9 and 12 MHz. Long-axis and short-axis ultrasound images of the abductor hallucis, flexor digitorum brevis, and quadratus plantae were obtained in both the non-weight-bearing and weight-bearing postures. Two examiners independently collected ultrasound images to allow for interexaminer and intraexaminer reliability calculation. The change in muscle CSA and dorsoplantar thickness when bearing weight was also studied. There were 26 participants (17 female) with a mean age of 25.5 ± 3.8 years and a mean body mass index of 28.0 ± 7.8 kg/m 2 . Inter-examiner reliability was excellent when measuring the muscles in short axis (intraclass correlation coefficient >0.75) and fair to good in long axis (intraclass correlation coefficient >0.4). Intraexaminer reliability was excellent for the abductor hallucis and flexor digitorum brevis and ranged from fair to good to excellent for the quadratus plantae. Bearing weight did not reduce interexaminer or intraexaminer reliability. All muscles exhibited a significant increase in CSA when bearing weight. This is the first report to describe weight-bearing diagnostic ultrasound of the intrinsic foot muscles. Ultrasound imaging is reliable when imaging these muscles bearing weight. Furthermore, muscle CSA increases in the weight-bearing posture. Copyright © 2016. Published by Elsevier Inc.
Application of image recognition-based automatic hyphae detection in fungal keratitis.
Wu, Xuelian; Tao, Yuan; Qiu, Qingchen; Wu, Xinyi
2018-03-01
The purpose of this study is to evaluate the accuracy of two methods in diagnosis of fungal keratitis, whereby one method is automatic hyphae detection based on images recognition and the other method is corneal smear. We evaluate the sensitivity and specificity of the method in diagnosis of fungal keratitis, which is automatic hyphae detection based on image recognition. We analyze the consistency of clinical symptoms and the density of hyphae, and perform quantification using the method of automatic hyphae detection based on image recognition. In our study, 56 cases with fungal keratitis (just single eye) and 23 cases with bacterial keratitis were included. All cases underwent the routine inspection of slit lamp biomicroscopy, corneal smear examination, microorganism culture and the assessment of in vivo confocal microscopy images before starting medical treatment. Then, we recognize the hyphae images of in vivo confocal microscopy by using automatic hyphae detection based on image recognition to evaluate its sensitivity and specificity and compare with the method of corneal smear. The next step is to use the index of density to assess the severity of infection, and then find the correlation with the patients' clinical symptoms and evaluate consistency between them. The accuracy of this technology was superior to corneal smear examination (p < 0.05). The sensitivity of the technology of automatic hyphae detection of image recognition was 89.29%, and the specificity was 95.65%. The area under the ROC curve was 0.946. The correlation coefficient between the grading of the severity in the fungal keratitis by the automatic hyphae detection based on image recognition and the clinical grading is 0.87. The technology of automatic hyphae detection based on image recognition was with high sensitivity and specificity, able to identify fungal keratitis, which is better than the method of corneal smear examination. This technology has the advantages when compared with the conventional artificial identification of confocal microscope corneal images, of being accurate, stable and does not rely on human expertise. It was the most useful to the medical experts who are not familiar with fungal keratitis. The technology of automatic hyphae detection based on image recognition can quantify the hyphae density and grade this property. Being noninvasive, it can provide an evaluation criterion to fungal keratitis in a timely, accurate, objective and quantitative manner.
Power Doppler evaluation of joint effusions: investigation in a rabbit model.
Strouse, P J; DiPietro, M A; Teo, E L; Doi, K; Chrisp, C E
1999-08-01
To study the power Doppler findings of septic arthritis and noninfectious synovitis in an animal model. The right knees of 10 rabbits were inoculated with an aqueous suspension of Staphylococcus aureus. The right knees of 5 rabbits were injected with talc suspension. The right knees of 5 rabbits were injected with saline. All 20 left knees were injected with saline. Serial power Doppler images were obtained using constant-imaging parameters. Images were reviewed by blinded observers who assessed for increased power Doppler signal. All 10 knees inoculated with S. aureus developed septic arthritis. Each infected rabbit knee demonstrated increased signal on power Doppler on at least one examination, ranging from 1-6 days after inoculation. Only 23 of 45 examinations of infected knees were unequivocally positive by power Doppler on examinations performed 1 to 6 days after inoculation. No knee with talc synovitis demonstrated increased power Doppler signal. No control knee demonstrated increased power Doppler signal. Increased power Doppler signal may be seen with septic arthritis; however, its intensity and timing may vary from subject to subject. A normal power Doppler examination does not exclude septic arthritis.
USDA-ARS?s Scientific Manuscript database
Infrared imaging is gaining attention as a technique used in the examination of cotton fibers. This type of imaging combines spectral analysis with spatial resolution to create visual images that examine sample composition and distribution. Herein, we report the use of an infrared instrument equippe...
Comparison of 3D bone models of the knee joint derived from CT and 3T MR imaging.
Neubert, Aleš; Wilson, Katharine J; Engstrom, Craig; Surowiec, Rachel K; Paproki, Anthony; Johnson, Nicholas; Crozier, Stuart; Fripp, Jurgen; Ho, Charles P
2017-08-01
To examine whether magnetic resonance (MR) imaging can offer a viable alternative to computed tomography (CT) based 3D bone modeling. CT and MR (SPACE, TrueFISP, VIBE) images were acquired from the left knee joint of a fresh-frozen cadaver. The distal femur, proximal tibia, proximal fibula and patella were manually segmented from the MR and CT examinations. The MR bone models obtained from manual segmentations of all three sequences were compared to CT models using a similarity measure based on absolute mesh differences. The average absolute distance between the CT and the various MR-based bone models were all below 1mm across all bones. The VIBE sequence provided the best agreement with the CT model, followed by the SPACE, then the TrueFISP data. The most notable difference was for the proximal tibia (VIBE 0.45mm, SPACE 0.82mm, TrueFISP 0.83mm). The study indicates that 3D MR bone models may offer a feasible alternative to traditional CT-based modeling. A single radiological examination using the MR imaging would allow simultaneous assessment of both bones and soft-tissues, providing anatomically comprehensive joint models for clinical evaluation, without the ionizing radiation of CT imaging. Copyright © 2017 Elsevier B.V. All rights reserved.
Childhood Abuse, Body Image Disturbance, and Eating Disorders.
ERIC Educational Resources Information Center
Schaaf, Kristin K.; McCanne, Thomas R.
1994-01-01
This study examined the relationships among childhood sexual and physical abuse, body image disturbance, and eating disorder symptomatology in college students, of whom 29 had been sexually abused, 32 physically abused, and 29 nonabused. There was no evidence that child sexual or physical abuse was associated with the development of body image…
This study examined inter-analyst classification variability based on training site signature selection only for six classifications from a 10 km2 Landsat ETM+ image centered over a highly heterogeneous area in south-central Virginia. Six analysts classified the image...
ERIC Educational Resources Information Center
Slater, Amy; Tiggemann, Marika
2011-01-01
This study examined gender differences in adolescent participation in sport and physical activity, in teasing experiences specific to the physical activity domain, and the relationship between adolescent physical activity and body image. A sample of 714 adolescents (332 girls, 382 boys) aged between 12 and 16 years completed measures of…
Monitoring cotton (Gossypium hirsutum L.) germination using ultrahigh-resolution UAS images
USDA-ARS?s Scientific Manuscript database
Examination of seed germination rate is of great importance for growers early in the season to determine the necessity for replanting their fields. The objective of this study was to explore the potential of using unmanned aircraft system (UAS)-based visible-band images to monitor and quantify the c...
Olympus Imaging Fraud Scandal: A Case Study
ERIC Educational Resources Information Center
Elam, Dennis; Madrigal, Marion; Jackson, Maura
2014-01-01
This case examines the two decade long tobashi scheme by Olympus Imaging Executives to hide $1.7 billion in losses. In the 1980s, a soaring yen and falling dollar caused bottom line income problems for many Japanese companies. Some companies sought to offset the declining revenue with zaiteku, a form of speculative investment. While early…
The Role and Design of Screen Images in Software Documentation.
ERIC Educational Resources Information Center
van der Meij, Hans
2000-01-01
Discussion of learning a new computer software program focuses on how to support the joint handling of a manual, input devices, and screen display. Describes a study that examined three design styles for manuals that included screen images to reduce split-attention problems and discusses theory versus practice and cognitive load theory.…
ERIC Educational Resources Information Center
Connell, Louise; Lynott, Dermot
2012-01-01
Abstract concepts are traditionally thought to differ from concrete concepts by their lack of perceptual information, which causes them to be processed more slowly and less accurately than perceptually-based concrete concepts. In two studies, we examined this assumption by comparing concreteness and imageability ratings to a set of perceptual…
The Internet as a Reflective Mirror for a Company's Image.
ERIC Educational Resources Information Center
Fahrmann, Jennifer; Hartz, Kim; Wendling, Marijo; Yoder, Kevin
The Internet is becoming the primary way that businesses communicate and receive information. Corporate Web addresses and home pages have become a valuable tool for leaving a solid mark on potential clients, consumers, and competition. To determine how differences in Web pages design reflect corporate image, a study examined Web pages from two…
"Mathematicians Would Say It This Way": An Investigation of Teachers' Framings of Mathematicians
ERIC Educational Resources Information Center
Cirillo, Michelle; Herbel-Eisenmann, Beth
2011-01-01
Although popular media often provides negative images of mathematicians, we contend that mathematics classroom practices can also contribute to students' images of mathematicians. In this study, we examined eight mathematics teachers' framings of mathematicians in their classrooms. Here, we analyze classroom observations to explore some of the…
Masculinity and femininity in the divergence of male body image concerns
2013-01-01
Background Given recent assertions suggesting that gender role endorsement may be relevant in the divergence of male body image concerns, this study examined the self-reported gender role endorsement in opposing dimensional extremes of male body image disorders, namely, muscle dysmorphia and anorexia nervosa. This study further examined the relationship between gender role endorsement and eating disordered and muscle dysmorphia disorder pathology. Methodology Participants were 21 male muscle dysmorphia patients, 24 male anorexia nervosa patients, and 30 male gym-using controls from Australia, the United Kingdom, and the United States. All participants completed multidimensional measures of masculinity and femininity, and measures of eating disorder and muscle dysmorphia symptomatology. Results Patients with muscle dysmorphia reported significantly elevated adherence to masculine (but not feminine) norms relative to control gym-using men and men with anorexia nervosa, whereas patients with anorexia nervosa exhibited elevated feminine (but not masculine) gender role endorsement relative to control gym-using men and men with muscle dysmorphia. Conclusions Masculine and feminine gender role endorsement appear to be associated with the divergence of body image concerns towards muscularity and thinness-oriented ideals respectively. PMID:24999393
Masculinity and femininity in the divergence of male body image concerns.
Murray, Stuart B; Rieger, Elizabeth; Karlov, Lisa; Touyz, Stephen W
2013-01-01
Given recent assertions suggesting that gender role endorsement may be relevant in the divergence of male body image concerns, this study examined the self-reported gender role endorsement in opposing dimensional extremes of male body image disorders, namely, muscle dysmorphia and anorexia nervosa. This study further examined the relationship between gender role endorsement and eating disordered and muscle dysmorphia disorder pathology. Participants were 21 male muscle dysmorphia patients, 24 male anorexia nervosa patients, and 30 male gym-using controls from Australia, the United Kingdom, and the United States. All participants completed multidimensional measures of masculinity and femininity, and measures of eating disorder and muscle dysmorphia symptomatology. Patients with muscle dysmorphia reported significantly elevated adherence to masculine (but not feminine) norms relative to control gym-using men and men with anorexia nervosa, whereas patients with anorexia nervosa exhibited elevated feminine (but not masculine) gender role endorsement relative to control gym-using men and men with muscle dysmorphia. Masculine and feminine gender role endorsement appear to be associated with the divergence of body image concerns towards muscularity and thinness-oriented ideals respectively.
[The role of sustained attention in shift-contingent change blindness].
Nakashima, Ryoichi; Yokosawa, Kazuhiko
2015-02-01
Previous studies of change blindness have examined the effect of temporal factors (e.g., blank duration) on attention in change detection. This study examined the effect of spatial factors (i.e., whether the locations of original and changed objects are the same or different) on attention in change detection, using a shift-contingent change blindness task. We used a flicker paradigm in which the location of a to-be-judged target image was manipulated (shift, no-shift). In shift conditions, the image of an array of objects was spatially shifted so that all objects appeared in new locations; in no-shift conditions, all object images of an array appeared at the same location. The presence of visual stimuli (dots) in the blank display between the two images was.manipulated (dot, no-dot) under the assumption that abrupt onsets of these stimuli would capture attention. Results indicated that change detection performance was improved by exogenous attentional capture in the shift condition. Thus, we suggest that attention can play an important role in change detection during shift-contingent change blindness.
Spatial data software integration - Merging CAD/CAM/mapping with GIS and image processing
NASA Technical Reports Server (NTRS)
Logan, Thomas L.; Bryant, Nevin A.
1987-01-01
The integration of CAD/CAM/mapping with image processing using geographic information systems (GISs) as the interface is examined. Particular emphasis is given to the development of software interfaces between JPL's Video Image Communication and Retrieval (VICAR)/Imaged Based Information System (IBIS) raster-based GIS and the CAD/CAM/mapping system. The design and functions of the VICAR and IBIS are described. Vector data capture and editing are studied. Various software programs for interfacing between the VICAR/IBIS and CAD/CAM/mapping are presented and analyzed.
Eliminate background interference from latent fingerprints using ultraviolet multispectral imaging
NASA Astrophysics Data System (ADS)
Huang, Wei; Xu, Xiaojing; Wang, Guiqiang
2014-02-01
Fingerprints are the most important evidence in crime scene. The technology of developing latent fingerprints is one of the hottest research areas in forensic science. Recently, multispectral imaging which has shown great capability in fingerprints development, questioned document detection and trace evidence examination is used in detecting material evidence. This paper studied how to eliminate background interference from non-porous and porous surface latent fingerprints by rotating filter wheel ultraviolet multispectral imaging. The results approved that background interference could be removed clearly from latent fingerprints by using multispectral imaging in ultraviolet bandwidth.
Reasoning strategies modulate gender differences in emotion processing.
Markovits, Henry; Trémolière, Bastien; Blanchette, Isabelle
2018-01-01
The dual strategy model of reasoning has proposed that people's reasoning can be understood asa combination of two different ways of processing information related to problem premises: a counterexample strategy that examines information for explicit potential counterexamples and a statistical strategy that uses associative access to generate a likelihood estimate of putative conclusions. Previous studies have examined this model in the context of basic conditional reasoning tasks. However, the information processing distinction that underlies the dual strategy model can be seen asa basic description of differences in reasoning (similar to that described by many general dual process models of reasoning). In two studies, we examine how these differences in reasoning strategy may relate to processing very different information, specifically we focus on previously observed gender differences in processing negative emotions. Study 1 examined the intensity of emotional reactions to a film clip inducing primarily negative emotions. Study 2 examined the speed at which participants determine the emotional valence of sequences of negative images. In both studies, no gender differences were observed among participants using a counterexample strategy. Among participants using a statistical strategy, females produce significantly stronger emotional reactions than males (in Study 1) and were faster to recognize the valence of negative images than were males (in Study 2). Results show that the processing distinction underlying the dual strategy model of reasoning generalizes to the processing of emotions. Copyright © 2017 Elsevier B.V. All rights reserved.
Contrast-to-noise ratio in magnification mammography: a Monte Carlo study
NASA Astrophysics Data System (ADS)
Koutalonis, M.; Delis, H.; Spyrou, G.; Costaridou, L.; Tzanakos, G.; Panayiotakis, G.
2007-06-01
Magnification views are a common way to perform a secondary examination when suspicious abnormalities are found in a screening mammogram. The visibility of microcalcifications and breast lesions is restricted by the compromise between the image quality and the absorbed dose. In this study, image quality characteristics in magnification mammography were evaluated based on Monte Carlo techniques. A breast phantom was utilized, simulating a homogeneous mixture of adipose and glandular tissue in various percentages of glandularity, containing inhomogeneities of various sizes and compositions. The effect of the magnification degree, breast glandularity, tube voltage and anode/filter material combination on image quality characteristics was investigated in terms of a contrast-to-noise ratio (CNR). A performance index PIν was introduced in order to study the overall performance of various anode/filter combinations under different exposure parameters. Results demonstrate that CNR is improved with the degree of magnification and degraded as the breast glandularity is increased. Degree of magnification 1.3 offers the best overall performance for most of the anode/filter combinations utilized. Under magnification conditions, the role of dose is demoted against the image quality, as magnification views are secondary, diagnostic examinations and not screening procedures oriented to non-symptomatic women. For decreased image quality weighting, some anode/filter combinations different from Mo/0.030mmMo can be utilized as they offer a similar performance index. However, if the desired weighting for the image quality is high, the Mo/0.030mmMo combination has the best overall performance.
Hiding Information Using different lighting Color images
NASA Astrophysics Data System (ADS)
Majead, Ahlam; Awad, Rash; Salman, Salema S.
2018-05-01
The host medium for the secret message is one of the important principles for the designers of steganography method. In this study, the best color image was studied to carrying any secret image.The steganography approach based Lifting Wavelet Transform (LWT) and Least Significant Bits (LSBs) substitution. The proposed method offers lossless and unnoticeable changes in the contrast carrier color image and imperceptible by human visual system (HVS), especially the host images which was captured in dark lighting conditions. The aim of the study was to study the process of masking the data in colored images with different light intensities. The effect of the masking process was examined on the images that are classified by a minimum distance and the amount of noise and distortion in the image. The histogram and statistical characteristics of the cover image the results showed the efficient use of images taken with different light intensities in hiding data using the least important bit substitution method. This method succeeded in concealing textual data without distorting the original image (low light) Lire developments due to the concealment process.The digital image segmentation technique was used to distinguish small areas with masking. The result is that smooth homogeneous areas are less affected as a result of hiding comparing with high light areas. It is possible to use dark color images to send any secret message between two persons for the purpose of secret communication with good security.
Puckett, Yana; To, Alvin
2016-01-01
This study examines the inefficiencies of radiologic imaging transfers from one hospital to the other during pediatric trauma transfers in an era of cloud based information sharing. Retrospective review of all patients transferred to a pediatric trauma center from 2008-2014 was performed. Imaging was reviewed for whether imaging accompanied the patient, whether imaging was able to be uploaded onto computer for records, whether imaging had to be repeated, and whether imaging obtained at outside hospitals (OSH) was done per universal pediatric trauma guidelines. Of the 1761 patients retrospectively reviewed, 559 met our inclusion criteria. Imaging was sent with the patient 87.7% of the time. Imaging was unable to be uploaded 31.9% of the time. CT imaging had to be repeated 1.8% of the time. CT scan was not done per universal pediatric trauma guidelines 1.2% of the time. Our study demonstrated that current imaging transfer is inefficient, leads to excess ionizing radiation, and increased healthcare costs. Universal implementation of cloud based radiology has the potential to eliminate excess ionizing radiation to children, improve patient care, and save cost to healthcare system.
Enhancement of digital radiography image quality using a convolutional neural network.
Sun, Yuewen; Li, Litao; Cong, Peng; Wang, Zhentao; Guo, Xiaojing
2017-01-01
Digital radiography system is widely used for noninvasive security check and medical imaging examination. However, the system has a limitation of lower image quality in spatial resolution and signal to noise ratio. In this study, we explored whether the image quality acquired by the digital radiography system can be improved with a modified convolutional neural network to generate high-resolution images with reduced noise from the original low-quality images. The experiment evaluated on a test dataset, which contains 5 X-ray images, showed that the proposed method outperformed the traditional methods (i.e., bicubic interpolation and 3D block-matching approach) as measured by peak signal to noise ratio (PSNR) about 1.3 dB while kept highly efficient processing time within one second. Experimental results demonstrated that a residual to residual (RTR) convolutional neural network remarkably improved the image quality of object structural details by increasing the image resolution and reducing image noise. Thus, this study indicated that applying this RTR convolutional neural network system was useful to improve image quality acquired by the digital radiography system.
Ns-scaled time-gated fluorescence lifetime imaging for forensic document examination
NASA Astrophysics Data System (ADS)
Zhong, Xin; Wang, Xinwei; Zhou, Yan
2018-01-01
A method of ns-scaled time-gated fluorescence lifetime imaging (TFLI) is proposed to distinguish different fluorescent substances in forensic document examination. Compared with Video Spectral Comparator (VSC) which can examine fluorescence intensity images only, TFLI can detect questioned documents like falsification or alteration. TFLI system can enhance weak signal by accumulation method. The two fluorescence intensity images of the interval delay time tg are acquired by ICCD and fitted into fluorescence lifetime image. The lifetimes of fluorescence substances are represented by different colors, which make it easy to detect the fluorescent substances and the sequence of handwritings. It proves that TFLI is a powerful tool for forensic document examination. Furthermore, the advantages of TFLI system are ns-scaled precision preservation and powerful capture capability.
ERIC Educational Resources Information Center
Rundgren, Carl-Johan; Tibell, Lena A. E.
2010-01-01
Images, diagrams, and other forms of visualization are playing increasingly important roles in molecular life science teaching and research, both for conveying information and as conceptual tools, transforming the way we think about the events and processes the subject covers. This study examines how upper secondary and tertiary students interpret…
The media's representation of the ideal male body: a cause for muscle dysmorphia?
Leit, Richard A; Gray, James J; Pope, Harrison G
2002-04-01
This study sought to examine the effects of media images on men's attitudes toward their body appearance. A group of college men viewed advertisements showing muscular men, whereas a control group viewed neutral advertisements. Immediately thereafter, participants performed a computerized test of body image perception while unaware of the hypotheses being tested in the study. The students exposed to the muscular images showed a significantly greater discrepancy between their own perceived muscularity and the level of muscularity that they ideally wanted to have. These findings suggest that media images, even in a brief presentation, can affect men's views of their bodies. Copyright 2002 by Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Watson, Jennifer M.
Ovarian cancer is a deadly disease owing to the non-specific symptoms and suspected rapid progression, leading to frequent late stage detection and poor prognosis. Medical imaging methods such as CT, MRI and ultrasound as well as serum testing for cancer markers have had extremely poor performance for early disease detection. Due to the poor performance of available screening methods, and the impracticality and ineffectiveness of taking tissue biopsies from the ovary, women at high risk for developing ovarian cancer are often advised to undergo prophylactic salpingo-oophorectomy. This surgery results in many side effects and is most often unnecessary since only a fraction of high risk women go on to develop ovarian cancer. Better understanding of the early development of ovarian cancer and characterization of morphological changes associated with early disease could lead to the development of an effective screening test for women at high risk. Optical imaging methods including optical coherence tomography (OCT) and multiphoton microscopy (MPM) are excellent tools for studying disease progression owing to the high resolution and depth sectioning capabilities. Further, these techniques are excellent for optical biopsy because they can image in situ non-destructively. In the studies described in this dissertation OCT and MPM are used to identify cellular and tissue morphological changes associated with early tumor development in a mouse model of ovarian cancer. This work is organized into three specific aims. The first aim is to use the images from the MPM phenomenon of second harmonic generation to quantitatively examine the morphological differences in collagen structure in normal mouse ovarian tissue and mouse ovarian tumors. The second aim is to examine the differences in endogenous two-photon excited fluorescence in normal mouse ovarian tissue and mouse ovarian tumors. The third and final aim is to identify changes in ovarian microstructure resulting from early disease development by imaging animals in vivo at three time points during a long-term survival study.
Visual adaptation and the amplitude spectra of radiological images.
Kompaniez-Dunigan, Elysse; Abbey, Craig K; Boone, John M; Webster, Michael A
2018-01-01
We examined how visual sensitivity and perception are affected by adaptation to the characteristic amplitude spectra of X-ray mammography images. Because of the transmissive nature of X-ray photons, these images have relatively more low-frequency variability than natural images, a difference that is captured by a steeper slope of the amplitude spectrum (~ - 1.5) compared to the ~ 1/f (slope of - 1) spectra common to natural scenes. Radiologists inspecting these images are therefore exposed to a different balance of spectral components, and we measured how this exposure might alter spatial vision. Observers (who were not radiologists) were adapted to images of normal mammograms or the same images sharpened by filtering the amplitude spectra to shallower slopes. Prior adaptation to the original mammograms significantly biased judgments of image focus relative to the sharpened images, demonstrating that the images are sufficient to induce substantial after-effects. The adaptation also induced strong losses in threshold contrast sensitivity that were selective for lower spatial frequencies, though these losses were very similar to the threshold changes induced by the sharpened images. Visual search for targets (Gaussian blobs) added to the images was also not differentially affected by adaptation to the original or sharper images. These results complement our previous studies examining how observers adapt to the textural properties or phase spectra of mammograms. Like the phase spectrum, adaptation to the amplitude spectrum of mammograms alters spatial sensitivity and visual judgments about the images. However, unlike the phase spectrum, adaptation to the amplitude spectra did not confer a selective performance advantage relative to more natural spectra.
Factors that Influence Body Image Representations of Black Muslim Women
2008-01-01
Research on the body image perceptions of black women is limited. Although previous body image studies have explored the intersection between race and gender, the influence of religion has been neglected. Guided by a grounded theory framework, the focus of this investigation, conducted in Upstate New York, USA, was to examine the role of race and religion in the body image perceptions of 22 African-American Sunni Muslim women. Analysis of individual interviews revealed that, in contrast to using standard medical guidelines, participants’ views about their bodies were largely based on positive images of an earlier body size/shape, social and family expectations and contexts, cultural norms and values, and spirituality and religious beliefs. Although the body image perceptions of black Muslim women were similar to those expressed in previous body image studies with black women, participants expressed the importance of highlighting the spiritual versus physical self by adhering to religious guidelines regarding proper dress and appearance. These findings suggest that religion, race, and gender are all important factors to be considered when conducting body image studies with black women. PMID:18384923
Sirin, Selma; Goericke, Sophia L; Huening, Britta M; Stein, Anja; Kinner, Sonja; Felderhoff-Mueser, Ursula; Schweiger, Bernd
2013-10-01
Several studies have revealed the importance of brain imaging in term and preterm infants. The aim of this retrospective study was to review safety, handling, and image quality of MR brain imaging using a new 3 Tesla MR-compatible incubator. Between 02/2011 and 05/2012 100 brain MRIs (84 infants, mean gestational age 32.2 ± 4.7 weeks, mean postmenstrual age at imaging 40.6 ± 3.4 weeks) were performed using a 3 Tesla MR-compatible incubator with dedicated, compatible head coil. Seventeen examinations (13 infants, mean gestational age 35.1 ± 5.4 weeks, mean postmenstrual age at imaging 47.8 ± 7.4 weeks) with a standard head coil served as a control. Image analysis was performed by a neuroradiologist and a pediatric radiologist in consensus. All but two patients with known apnea were transferred to the MR unit and scanned without problems. Handling was easier and faster with the incubator; relevant motion artifacts (5.9 vs. 10.8%) and the need for repetitive sedation (43.0 vs. 86.7%) were reduced. Considering only images not impaired by motion artifacts, image quality (4.8 ± 0.4 vs. 4.3 ± 0.8, p = 0.047) and spatial resolution (4.7 ± 0.4 vs. 4.2 ± 0.6, p = 0.011) of T2-weighted images were scored significantly higher in patients imaged with the incubator. SNR increased significantly (171.6 ± 54.5 vs. 80.5 ± 19.8, p < 0.001) with the use of the incubator. Infants can benefit from the use of a 3 Tesla MR-compatible incubator because of its safety, easier, and faster handling (compared to standard imaging) and possibility to obtain high-quality MR images even in unstable patients.
Shloim, Netalie; Hetherington, Marion M; Rudolf, Mary; Feltbower, Richard G
2015-04-01
This study examined the relationship between self-esteem, restrained eating, body image and body mass index during pregnancy. A total of 110 pregnant Israeli and UK women completed the Rosenberg Self-Esteem Questionnaire, the Dutch Eating Behaviour Questionnaire, scales to assess body image and demographics. Body mass index was calculated from antenatal records. Regression modelling determined the relationship between variables, countries and body mass index categories. High correlations were found between body image and body mass index with significantly higher body dissatisfaction for Israeli women. Self-esteem scores for pregnant women were similar to those reported for non-pregnant women. Poorer body image and higher prevalence of restrained eating were found in healthy weight Israeli women. © The Author(s) 2013.
Correlates of mammographic density in B-mode ultrasound and real time elastography.
Jud, Sebastian Michael; Häberle, Lothar; Fasching, Peter A; Heusinger, Katharina; Hack, Carolin; Faschingbauer, Florian; Uder, Michael; Wittenberg, Thomas; Wagner, Florian; Meier-Meitinger, Martina; Schulz-Wendtland, Rüdiger; Beckmann, Matthias W; Adamietz, Boris R
2012-07-01
The aim of our study involved the assessment of B-mode imaging and elastography with regard to their ability to predict mammographic density (MD) without X-rays. Women, who underwent routine mammography, were prospectively examined with additional B-mode ultrasound and elastography. MD was assessed quantitatively with a computer-assisted method (Madena). The B-mode and elastography images were assessed by histograms with equally sized gray-level intervals. Regression models were built and cross validated to examine the ability to predict MD. The results of this study showed that B-mode imaging and elastography were able to predict MD. B-mode seemed to give a more accurate prediction. R for B-mode image and elastography were 0.67 and 0.44, respectively. Areas in the B-mode images that correlated with mammographic dense areas were either dark gray or of intermediate gray levels. Concerning elastography only the gray levels that represent extremely stiff tissue correlated positively with MD. In conclusion, ultrasound seems to be able to predict MD. Easy and cheap utilization of regular breast ultrasound machines encourages the use of ultrasound in larger case-control studies to validate this method as a breast cancer risk predictor. Furthermore, the application of ultrasound for breast tissue characterization could enable comprehensive research concerning breast cancer risk and breast density in young and pregnant women.
Identifying women with dense breasts at high risk for interval cancer: a cohort study.
Kerlikowske, Karla; Zhu, Weiwei; Tosteson, Anna N A; Sprague, Brian L; Tice, Jeffrey A; Lehman, Constance D; Miglioretti, Diana L
2015-05-19
Twenty-one states have laws requiring that women be notified if they have dense breasts and that they be advised to discuss supplemental imaging with their provider. To better direct discussions of supplemental imaging by determining which combinations of breast cancer risk and Breast Imaging Reporting and Data System (BI-RADS) breast density categories are associated with high interval cancer rates. Prospective cohort. Breast Cancer Surveillance Consortium (BCSC) breast imaging facilities. 365,426 women aged 40 to 74 years who had 831,455 digital screening mammography examinations. BI-RADS breast density, BCSC 5-year breast cancer risk, and interval cancer rate (invasive cancer ≤12 months after a normal mammography result) per 1000 mammography examinations. High interval cancer rate was defined as more than 1 case per 1000 examinations. High interval cancer rates were observed for women with 5-year risk of 1.67% or greater and extremely dense breasts or 5-year risk of 2.50% or greater and heterogeneously dense breasts (24% of all women with dense breasts). The interval rate of advanced-stage disease was highest (>0.4 case per 1000 examinations) among women with 5-year risk of 2.50% or greater and heterogeneously or extremely dense breasts (21% of all women with dense breasts). Five-year risk was low to average (0% to 1.66%) for 51.0% of women with heterogeneously dense breasts and 52.5% with extremely dense breasts, with interval cancer rates of 0.58 to 0.63 and 0.72 to 0.89 case per 1000 examinations, respectively. The benefit of supplemental imaging was not assessed. Breast density should not be the sole criterion for deciding whether supplemental imaging is justified because not all women with dense breasts have high interval cancer rates. BCSC 5-year risk combined with BI-RADS breast density can identify women at high risk for interval cancer to inform patient-provider discussions about alternative screening strategies. National Cancer Institute.
Analysis of discrepancies observed between digital and analog images during a clinical trial of IRIS
NASA Astrophysics Data System (ADS)
Goldberg, Morris; Coristine, Marjorie; Currie, Shawn; Belanger, Garry; Ahuja, J.; Dillon, Richard F.; Robertson, John G.
1990-08-01
A clinical trial of an Integrated Radiological Information System (IRIS) was conducted at the Ottawa Civic Hospital with the Department of Emergency Medicine and the Department of Radiological Sciences between April 4, and May 12, 1989. During the trial, 319 active Emergency Department cases (905 films) were processed using IRIS. Radiologists examined the digital images on the image screen to formulate a diagnosis, then before dictating a report, they examined the analog films. In 30 cases there was a discrepancy between the information obtained while viewing the digital images on IRIS and the information obtained from the analog films. These anomalous cases were used in an independent study of the discrepancies. In the study, each case was reviewed in both digital and analog form by three physicians who provided a comparative rating of diagnostic quality. Any perceived differences between the digital and analog media were noted. Particular attention was paid to rating the relevance of the IRIS enhancement capabilities. Although ratings for digital images were high, the comparative ratings for the film are in general better. An analysis of the individual cases shows that: (i) most of the discrepancies probably resulted from physician inexperience in reading radiographs in digital form, (ii) the IRIS enhancement facilities significantly increase the ratings of satisfaction or perceived quality of digital images and (iii) an appropriate choice of enhancement may make visible the required diagnostic features for cases where some reviewers did not find the image/digital discrepant.
NASA Astrophysics Data System (ADS)
Butler, M. L.; Rainford, L.; Last, J.; Brennan, P. C.
2009-02-01
Introduction The American Association of Medical Physicists is currently standardizing the exposure index (EI) value. Recent studies have questioned whether the EI value offered by manufacturers is optimal. This current work establishes optimum EIs for the antero-posterior (AP) projections of a pelvis and knee on a Carestream Health (Kodak) CR system and compares these with manufacturers recommended EI values from a patient dose and image quality perspective. Methodology Human cadavers were used to produce images of clinically relevant standards. Several exposures were taken to achieve various EI values and corresponding entrance surface doses (ESD) were measured using thermoluminescent dosimeters. Image quality was assessed by 5 experienced clinicians using anatomical criteria judged against a reference image. Visualization of image specific common abnormalities was also analyzed to establish diagnostic efficacy. Results A rise in ESD for both examinations, consistent with increasing EI was shown. Anatomic image quality was deemed to be acceptable at an EI of 1560 for the AP pelvis and 1590 for the AP knee. From manufacturers recommended values, a significant reduction in ESD (p=0.02) of 38% and 33% for the pelvis and knee respectively was noted. Initial pathological analysis suggests that diagnostic efficacy at lower EI values may be projection-specific. Conclusion The data in this study emphasize the need for clinical centres to consider establishing their own EI guidelines, and not necessarily relying on manufacturers recommendations. Normal and abnormal images must be used in this process.
Surfer’s Myelopathy: A Radiologic Study of 23 Cases
Nakamoto, B.K.; Siu, A.M.; Hashiba, K.A.; Sinclair, B.T.; Baker, B.J.; Gerber, M.S.; McMurtray, A.M.; Pearce, A.M.; Pearce, J.W.
2015-01-01
BACKGROUND AND PURPOSE Surfing is an uncommon cause of an acute nontraumatic myelopathy. This study describes the MR imaging characteristics and clinical correlates in 23 subjects with surfer’s myelopathy. MATERIALS AND METHODS This was a retrospective review of 23 cases of surfer’s myelopathy from 2003–2012. Spinal cord MR imaging characteristics and neurologic examinations with the use of the American Spinal Injury Association scale were reviewed. Logistic regression was used to determine associations between MR imaging characteristics, American Spinal Injury Association scale, and clinical improvement. RESULTS All subjects (19 male, 4 female; mean age, 26.3 ± 7.4 years) demonstrated “pencil-like,” central T2-hyperintense signal abnormalities in the spinal cord extending from the midthoracic region to the conus with associated cord expansion and varying degrees of conus enlargement on spinal cord MR imaging within 24 hours of symptom onset. T1 signal was normal. Faint gadolinium enhancement was present in a minority. Although there was a strong correlation between initial American Spinal Injury Association score and clinical improvement (P = .0032), MR imaging characteristics were not associated with American Spinal Injury Association score or clinical improvement. CONCLUSIONS Surfer’s myelopathy should be considered in the radiographic differential diagnosis of a longitudinally extensive T2-hyperintense spinal cord lesion. MR imaging characteristics do not appear to be associated with severity on examination or clinical improvement. PMID:23828111
Cook, Tessa S; Zimmerman, Stefan L; Steingall, Scott R; Maidment, Andrew D A; Kim, Woojin; Boonn, William W
2011-01-01
There is growing interest in the ability to monitor, track, and report exposure to radiation from medical imaging. Historically, however, dose information has been stored on an image-based dose sheet, an arrangement that precludes widespread indexing. Although scanner manufacturers are beginning to include dose-related parameters in the Digital Imaging and Communications in Medicine (DICOM) headers of imaging studies, there remains a vast repository of retrospective computed tomographic (CT) data with image-based dose sheets. Consequently, it is difficult for imaging centers to monitor their dose estimates or participate in the American College of Radiology (ACR) Dose Index Registry. An automated extraction software pipeline known as Radiation Dose Intelligent Analytics for CT Examinations (RADIANCE) has been designed that quickly and accurately parses CT dose sheets to extract and archive dose-related parameters. Optical character recognition of information in the dose sheet leads to creation of a text file, which along with the DICOM study header is parsed to extract dose-related data. The data are then stored in a relational database that can be queried for dose monitoring and report creation. RADIANCE allows efficient dose analysis of CT examinations and more effective education of technologists, radiologists, and referring physicians regarding patient exposure to radiation at CT. RADIANCE also allows compliance with the ACR's dose reporting guidelines and greater awareness of patient radiation dose, ultimately resulting in improved patient care and treatment.
Automated camera-phone experience with the frequency of imaging necessary to capture diet.
Arab, Lenore; Winter, Ashley
2010-08-01
Camera-enabled cell phones provide an opportunity to strengthen dietary recall through automated imaging of foods eaten during a specified period. To explore the frequency of imaging needed to capture all foods eaten, we examined the number of images of individual foods consumed in a pilot study of automated imaging using camera phones set to an image-capture frequency of one snapshot every 10 seconds. Food images were tallied from 10 young adult subjects who wore the phone continuously during the work day and consented to share their images. Based on the number of images received for each eating experience, the pilot data suggest that automated capturing of images at a frequency of once every 10 seconds is adequate for recording foods consumed during regular meals, whereas a greater frequency of imaging is necessary to capture snacks and beverages eaten quickly. 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.
Mraity, Hussien A A B; England, Andrew; Cassidy, Simon; Eachus, Peter; Dominguez, Alejandro; Hogg, Peter
2016-01-01
The aim of this article was to apply psychometric theory to develop and validate a visual grading scale for assessing the visual perception of digital image quality anteroposterior (AP) pelvis. Psychometric theory was used to guide scale development. Seven phantom and seven cadaver images of visually and objectively predetermined quality were used to help assess scale reliability and validity. 151 volunteers scored phantom images, and 184 volunteers scored cadaver images. Factor analysis and Cronbach's alpha were used to assess scale validity and reliability. A 24-item scale was produced. Aggregated mean volunteer scores for each image correlated with the rank order of the visually and objectively predetermined image qualities. Scale items had good interitem correlation (≥0.2) and high factor loadings (≥0.3). Cronbach's alpha (reliability) revealed that the scale has acceptable levels of internal reliability for both phantom and cadaver images (α = 0.8 and 0.9, respectively). Factor analysis suggested that the scale is multidimensional (assessing multiple quality themes). This study represents the first full development and validation of a visual image quality scale using psychometric theory. It is likely that this scale will have clinical, training and research applications. This article presents data to create and validate visual grading scales for radiographic examinations. The visual grading scale, for AP pelvis examinations, can act as a validated tool for future research, teaching and clinical evaluations of image quality.
England, Andrew; Cassidy, Simon; Eachus, Peter; Dominguez, Alejandro; Hogg, Peter
2016-01-01
Objective: The aim of this article was to apply psychometric theory to develop and validate a visual grading scale for assessing the visual perception of digital image quality anteroposterior (AP) pelvis. Methods: Psychometric theory was used to guide scale development. Seven phantom and seven cadaver images of visually and objectively predetermined quality were used to help assess scale reliability and validity. 151 volunteers scored phantom images, and 184 volunteers scored cadaver images. Factor analysis and Cronbach's alpha were used to assess scale validity and reliability. Results: A 24-item scale was produced. Aggregated mean volunteer scores for each image correlated with the rank order of the visually and objectively predetermined image qualities. Scale items had good interitem correlation (≥0.2) and high factor loadings (≥0.3). Cronbach's alpha (reliability) revealed that the scale has acceptable levels of internal reliability for both phantom and cadaver images (α = 0.8 and 0.9, respectively). Factor analysis suggested that the scale is multidimensional (assessing multiple quality themes). Conclusion: This study represents the first full development and validation of a visual image quality scale using psychometric theory. It is likely that this scale will have clinical, training and research applications. Advances in knowledge: This article presents data to create and validate visual grading scales for radiographic examinations. The visual grading scale, for AP pelvis examinations, can act as a validated tool for future research, teaching and clinical evaluations of image quality. PMID:26943836
Giesemann, Anja M; Raab, Peter; Lyutenski, Stefan; Dettmer, Sabine; Bültmann, Eva; Frömke, Cornelia; Lenarz, Thomas; Lanfermann, Heinrich; Goetz, Friedrich
2014-03-01
Magnetic resonance imaging of the temporal bone has an important role in decision making with regard to cochlea implantation, especially in children with cochlear nerve deficiency. The purpose of this study was to evaluate the usefulness of the combination of an advanced high-resolution T2-weighted sequence with a surface coil in a 3-Tesla magnetic resonance imaging scanner in cases of suspected cochlear nerve aplasia. Prospective study. Seven patients with cochlear nerve hypoplasia or aplasia were prospectively examined using a high-resolution three-dimensional variable flip-angle turbo spin-echo sequence using a surface coil, and the images were compared with the same sequence in standard resolution using a standard head coil. Three neuroradiologists evaluated the magnetic resonance images independently, rating the visibility of the nerves in diagnosing hypoplasia or aplasia. Eight ears in seven patients with hypoplasia or aplasia of the cochlear nerve were examined. The average age was 2.7 years (range, 9 months-5 years). Seven ears had accompanying malformations. The inter-rater reliability in diagnosing hypoplasia or aplasia was greater using the high-resolution three-dimensional variable flip-angle turbo spin-echo sequence (fixed-marginal kappa: 0.64) than with the same sequence in lower resolution (fixed-marginal kappa: 0.06). Examining cases of suspected cochlear nerve aplasia using the high-resolution three-dimensional variable flip-angle turbo spin-echo sequence in combination with a surface coil shows significant improvement over standard methods. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Alejo, L; Corredoira, E; Sánchez-Muñoz, F; Huerga, C; Aza, Z; Plaza-Núñez, R; Serrada, A; Bret-Zurita, M; Parrón, M; Prieto-Areyano, C; Garzón-Moll, G; Madero, R; Guibelalde, E
2018-04-09
Objective: The new 2013/59 EURATOM Directive (ED) demands dosimetric optimisation procedures without undue delay. The aim of this study was to optimise paediatric conventional radiology examinations applying the ED without compromising the clinical diagnosis. Automatic dose management software (ADMS) was used to analyse 2678 studies of children from birth to 5 years of age, obtaining local diagnostic reference levels (DRLs) in terms of entrance surface air kerma. Given local DRL for infants and chest examinations exceeded the European Commission (EC) DRL, an optimisation was performed decreasing the kVp and applying the automatic control exposure. To assess the image quality, an analysis of high-contrast resolution (HCSR), signal-to-noise ratio (SNR) and figure of merit (FOM) was performed, as well as a blind test based on the generalised estimating equations method. For newborns and chest examinations, the local DRL exceeded the EC DRL by 113%. After the optimisation, a reduction of 54% was obtained. No significant differences were found in the image quality blind test. A decrease in SNR (-37%) and HCSR (-68%), and an increase in FOM (42%), was observed. ADMS allows the fast calculation of local DRLs and the performance of optimisation procedures in babies without delay. However, physical and clinical analyses of image quality remain to be needed to ensure the diagnostic integrity after the optimisation process. Advances in knowledge: ADMS are useful to detect radiation protection problems and to perform optimisation procedures in paediatric conventional imaging without undue delay, as ED requires.
Estai, Mohamed; Kanagasingam, Yogesan; Xiao, Di; Vignarajan, Janardhan; Huang, Boyan; Kruger, Estie; Tennant, Marc
2016-09-01
It is widely considered that telemedicine can make positive contributions to dental practice. This study aimed to evaluate a cloud-based telemedicine application for screening for oral diseases. A telemedicine system, based on a store-and-forward method, was developed to work as a platform for data storage. An Android application was developed to facilitate entering demographic details and capturing oral photos. As a proof-of-concept, six volunteers were enrolled in a trial to obtain oral images using smartphone cameras. Following an onsite oral examination, images of participants' teeth were obtained by a trained dental assistant. Oral images were directly uploaded from the smartphone to a cloud-based server via broadband network. The assessments of oral images by offsite dentists were compared with those carried out via face-to-face oral examinations. A complete set of 30 oral images was obtained from all six participants. Out of 192 teeth reviewed, the proportion of ungradable teeth was 8%. Sensitivity and specificity of teledental screening were 57% and 100% respectively. The inter-grader agreement estimated for two examination modalities and between two teledental graders was 70% and 62% respectively. Findings indicate that the proposed system for screening of oral diseases can be implemented to provide a valid and reliable alternative to traditional oral screening. This study provided evidence that a robust system for store-and-forward screening for dental problems can be developed, and leads to the need for further testing of its robustness to confirm the accuracy and reliability of the teledentistry system. © The Author(s) 2015.
Notohamiprodjo, S; Deak, Z; Meurer, F; Maertz, F; Mueck, F G; Geyer, L L; Wirth, S
2015-01-01
The purpose of this study was to compare cranial CT (CCT) image quality (IQ) of the MBIR algorithm with standard iterative reconstruction (ASiR). In this institutional review board (IRB)-approved study, raw data sets of 100 unenhanced CCT examinations (120 kV, 50-260 mAs, 20 mm collimation, 0.984 pitch) were reconstructed with both ASiR and MBIR. Signal-to-noise (SNR) and contrast-to-noise (CNR) were calculated from attenuation values measured in caudate nucleus, frontal white matter, anterior ventricle horn, fourth ventricle, and pons. Two radiologists, who were blinded to the reconstruction algorithms, evaluated anonymized multiplanar reformations of 2.5 mm with respect to depiction of different parenchymal structures and impact of artefacts on IQ with a five-point scale (0: unacceptable, 1: less than average, 2: average, 3: above average, 4: excellent). MBIR decreased artefacts more effectively than ASiR (p < 0.01). The median depiction score for MBIR was 3, whereas the median value for ASiR was 2 (p < 0.01). SNR and CNR were significantly higher in MBIR than ASiR (p < 0.01). MBIR showed significant improvement of IQ parameters compared to ASiR. As CCT is an examination that is frequently required, the use of MBIR may allow for substantial reduction of radiation exposure caused by medical diagnostics. • Model-Based iterative reconstruction (MBIR) effectively decreased artefacts in cranial CT. • MBIR reconstructed images were rated with significantly higher scores for image quality. • Model-Based iterative reconstruction may allow reduced-dose diagnostic examination protocols.
Complementary aspects of diffusion imaging and fMRI; I: structure and function.
Mulkern, Robert V; Davis, Peter E; Haker, Steven J; Estepar, Raul San Jose; Panych, Lawrence P; Maier, Stephan E; Rivkin, Michael J
2006-05-01
Studying the intersection of brain structure and function is an important aspect of modern neuroscience. The development of magnetic resonance imaging (MRI) over the last 25 years has provided new and powerful tools for the study of brain structure and function. Two tools in particular, diffusion imaging and functional MRI (fMRI), are playing increasingly important roles in elucidating the complementary aspects of brain structure and function. In this work, we review basic technical features of diffusion imaging and fMRI for studying the integrity of white matter structural components and for determining the location and extent of cortical activation in gray matter, respectively. We then review a growing body of literature in which the complementary aspects of diffusion imaging and fMRI, applied as separate examinations but analyzed in tandem, have been exploited to enhance our knowledge of brain structure and function.
Kaminsky, Laura A; Dewey, Deborah
2014-08-01
To examine the associations between body mass index (BMI) and physical activity with body image, self-esteem and social support in adolescents with type 1 diabetes compared to adolescents without health conditions. We studied 46 adolescents with type 1 diabetes and 27 comparison adolescents who provided self-reports of height and weight, which were used to calculate BMI z-scores. Participants also completed validated questionnaires that assessed physical activity, body image, self-esteem and social support. No significant group differences were found between adolescents with type 1 diabetes and comparison adolescents in terms of BMI and physical activity. Examination of group and gender revealed that higher BMI was significantly associated with a less positive body image in girls with diabetes only. Higher BMI was associated with poorer self-esteem and lower levels of social support in adolescents with diabetes, particularly girls. Higher levels of physical activity were not associated with a more positive body image and no significant associations were found between physical activity and self-esteem or social support. BMI and physical activity levels of adolescents with type 1 diabetes do not differ from those of adolescents without diabetes. Higher BMI is associated with a less positive body image and poorer psychosocial outcomes, particularly in girls with diabetes. As body image concerns and various psychosocial factors could be precursors to the development of eating-disorder symptoms, future research in adolescents with diabetes with higher BMIs should examine the associations among these variables. Further, it is essential that research on body image take into account gender differences. Copyright © 2014 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.
Tojo, Naoki; Nakamura, Tomoko; Fuchizawa, Chiharu; Oiwake, Toshihiko; Hayashi, Atsushi
2013-01-01
The purpose of this study was to examine cone photoreceptors in the macula of patients with retinitis pigmentosa using an adaptive optics fundus camera and to investigate any correlations between cone photoreceptor density and findings on optical coherence tomography and fundus autofluorescence. We examined two patients with typical retinitis pigmentosa who underwent ophthalmological examination, including measurement of visual acuity, and gathering of electroretinographic, optical coherence tomographic, fundus autofluorescent, and adaptive optics fundus images. The cone photoreceptors in the adaptive optics images of the two patients with retinitis pigmentosa and five healthy subjects were analyzed. An abnormal parafoveal ring of high-density fundus autofluorescence was observed in the macula in both patients. The border of the ring corresponded to the border of the external limiting membrane and the inner segment and outer segment line in the optical coherence tomographic images. Cone photoreceptors at the abnormal parafoveal ring were blurred and decreased in the adaptive optics images. The blurred area corresponded to the abnormal parafoveal ring in the fundus autofluorescence images. Cone densities were low at the blurred areas and at the nasal and temporal retina along a line from the fovea compared with those of healthy controls. The results for cone spacing and Voronoi domains in the macula corresponded with those for the cone densities. Cone densities were heavily decreased in the macula, especially at the parafoveal ring on high-density fundus autofluorescence in both patients with retinitis pigmentosa. Adaptive optics images enabled us to observe in vivo changes in the cone photoreceptors of patients with retinitis pigmentosa, which corresponded to changes in the optical coherence tomographic and fundus autofluorescence images.
Albert, Kimberly; Gau, Violet; Taylor, Warren D; Newhouse, Paul A
2017-03-01
Cognitive bias is a common characteristic of major depressive disorder (MDD) and is posited to remain during remission and contribute to recurrence risk. Attention bias may be related to enhanced amygdala activity or altered amygdala functional connectivity in depression. The current study examined attention bias, brain activity for emotional images, and functional connectivity in post-menopausal women with and without a history of major depression. Attention bias for emotionally valenced images was examined in 33 postmenopausal women with (n=12) and without (n=21) a history of major depression using an emotion dot probe task during fMRI. Group differences in amygdala activity and functional connectivity were assessed using fMRI and examined for correlations to attention performance. Women with a history of MDD showed greater attentional bias for negative images and greater activity in brain areas including the amygdala for both positive and negative images (pcorr <0.001) than women without a history of MDD. In all participants, amygdala activity for negative images was correlated with attention facilitation for emotional images. Women with a history of MDD had significantly greater functional connectivity between the amygdala and hippocampal complex. In all participants amygdala-hippocampal connectivity was positively correlated with attention facilitation for negative images. Small sample with unbalanced groups. These findings provide evidence for negative attentional bias in euthymic, remitted depressed individuals. Activity and functional connectivity in limbic and attention networks may provide a neurobiological basis for continued cognitive bias in remitted depression. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Stevens, G. H.; Ramler, J. R.
1974-01-01
A preliminary study was made of a radar imaging satellite for earth applications. A side-looking synthetic-aperture radar was considered and the feasibility of obtaining a wide area coverage to reduce the time required to image a given area was investigated. Two basic approaches were examined; low altitude sun-synchronous orbits using a multibeam/multifrequency radar system and equatorial orbits up to near-synchronous altitude using a single beam system. Surveillance and mapping of ice on the Great Lakes was used as a typical application to focus the study effort.
Accurate registration of temporal CT images for pulmonary nodules detection
NASA Astrophysics Data System (ADS)
Yan, Jichao; Jiang, Luan; Li, Qiang
2017-02-01
Interpretation of temporal CT images could help the radiologists to detect some subtle interval changes in the sequential examinations. The purpose of this study was to develop a fully automated scheme for accurate registration of temporal CT images for pulmonary nodule detection. Our method consisted of three major registration steps. Firstly, affine transformation was applied in the segmented lung region to obtain global coarse registration images. Secondly, B-splines based free-form deformation (FFD) was used to refine the coarse registration images. Thirdly, Demons algorithm was performed to align the feature points extracted from the registered images in the second step and the reference images. Our database consisted of 91 temporal CT cases obtained from Beijing 301 Hospital and Shanghai Changzheng Hospital. The preliminary results showed that approximately 96.7% cases could obtain accurate registration based on subjective observation. The subtraction images of the reference images and the rigid and non-rigid registered images could effectively remove the normal structures (i.e. blood vessels) and retain the abnormalities (i.e. pulmonary nodules). This would be useful for the screening of lung cancer in our future study.
Choosing the negative: A behavioral demonstration of morbid curiosity
2017-01-01
This paper examined, with a behavioral paradigm, to what extent people choose to view stimuli that portray death, violence or harm. Based on briefly presented visual cues, participants made choices between highly arousing, negative images and positive or negative alternatives. The negative images displayed social scenes that involved death, violence or harm (e.g., war scene), or decontextualized, close-ups of physical harm (e.g., mutilated face) or natural threat (e.g., attacking shark). The results demonstrated that social negative images were chosen significantly more often than other negative categories. Furthermore, participants preferred social negative images over neutral images. Physical harm images and natural threat images were not preferred over neutral images, but were chosen in about thirty-five percent of the trials. These results were replicated across three different studies, including a study that presented verbal descriptions of images as pre-choice cues. Together, these results show that people deliberately subject themselves to negative images. With this, the present paper demonstrates a dynamic relationship between negative information and behavior and advances new insights into the phenomenon of morbid curiosity. PMID:28683147
3D ocular ultrasound using gaze tracking on the contralateral eye: a feasibility study.
Afsham, Narges; Najafi, Mohammad; Abolmaesumi, Purang; Rohling, Robert
2011-01-01
A gaze-deviated examination of the eye with a 2D ultrasound transducer is a common and informative ophthalmic test; however, the complex task of the pose estimation of the ultrasound images relative to the eye affects 3D interpretation. To tackle this challenge, a novel system for 3D image reconstruction based on gaze tracking of the contralateral eye has been proposed. The gaze fixates on several target points and, for each fixation, the pose of the examined eye is inferred from the gaze tracking. A single camera system has been developed for pose estimation combined with subject-specific parameter identification. The ultrasound images are then transformed to the coordinate system of the examined eye to create a 3D volume. Accuracy of the proposed gaze tracking system and the pose estimation of the eye have been validated in a set of experiments. Overall system error, including pose estimation and calibration, are 3.12 mm and 4.68 degrees.
Reliability and discriminatory power of methods for dental plaque quantification
RAGGIO, Daniela Prócida; BRAGA, Mariana Minatel; RODRIGUES, Jonas Almeida; FREITAS, Patrícia Moreira; IMPARATO, José Carlos Pettorossi; MENDES, Fausto Medeiros
2010-01-01
Objective This in situ study evaluated the discriminatory power and reliability of methods of dental plaque quantification and the relationship between visual indices (VI) and fluorescence camera (FC) to detect plaque. Material and Methods Six volunteers used palatal appliances with six bovine enamel blocks presenting different stages of plaque accumulation. The presence of plaque with and without disclosing was assessed using VI. Images were obtained with FC and digital camera in both conditions. The area covered by plaque was assessed. Examinations were done by two independent examiners. Data were analyzed by Kruskal-Wallis and Kappa tests to compare different conditions of samples and to assess the inter-examiner reproducibility. Results Some methods presented adequate reproducibility. The Turesky index and the assessment of area covered by disclosed plaque in the FC images presented the highest discriminatory powers. Conclusions The Turesky index and images with FC with disclosing present good reliability and discriminatory power in quantifying dental plaque. PMID:20485931
Substance Use and Its Relationship to Family Functioning and Self-Image in Adolescents
ERIC Educational Resources Information Center
Weiss, Jie Wu; Merrill, Vincent; Akagha, Kathy
2011-01-01
This study examined associations between substance use, family functioning, and self-image among four ethnic adolescent groups. Three thousand three hundred and fifteen 8th and 9th grade students were recruited from 10 schools in Los Angeles County. Participants completed a paper-and-pencil survey regarding their alcohol and marijuana use, along…
ERIC Educational Resources Information Center
Lowery, Sarah E.; Kurpius, Sharon E. Robinson; Befort, Christie; Blanks, Elva Hull; Sollenberger, Sonja; Nicpon, Megan Foley; Huser, Laura
2005-01-01
This study examined the relationships among self-esteem, body image, and health-related behaviors of 267 female and 156 male first-year college students. Data were collected in 23 classrooms. Instruments included a demographic sheet, the Objectified Body Consciousness Scale, the Weight and Appearance Visual Analogue Scales, the Contour Drawing…
ERIC Educational Resources Information Center
Callaghan, Glenn M.; Duenas, Julissa A.; Nadeau, Sarah E.; Darrow, Sabrina M.; Van der Merwe, Jessica; Misko, Jennifer
2012-01-01
The literature examining body image disturbance and Body Dysmorphic Disorder (BDD) is fraught with competing theoretical constructions of the etiology and nosology of these problems. Recent studies on various forms of psychopathology suggest that intrapersonal processes, including experiential avoidance, and interpersonal processes such as…
ERIC Educational Resources Information Center
Turnage, Barbara F.
2004-01-01
This study of 105 senior high school Southern African American adolescent females examined the relationship between global self-esteem, appearance evaluation (body image), and ethnic identity. As predicted, the relationship between global self-esteem, appearance evaluation (r = 0.46, p less than 0.001), and ethnic identity (r = 40, p less than…
Spatiotemporal Analysis of High-Speed Videolaryngoscopic Imaging of Organic Pathologies in Males
ERIC Educational Resources Information Center
Bohr, Christopher; Kräck, Angelika; Dubrovskiy Denis; Eysholdt, Ulrich; Svec, Jan; Psychogios, Georgios; Ziethe, Anke; Döllinger, Michael
2014-01-01
Purpose: The aim of this study was to identify parameters that would differentiate healthy from pathological organic-based vocal fold vibrations to emphasize clinical usefulness of high-speed imaging. Method: Fifty-five men (M age = 36 years, SD = 20 years) were examined and separated into 4 groups: 1 healthy (26 individuals) and 3 pathological…
Contextual Worlds of Child Art: Experiencing Multiple Literacies through Images
ERIC Educational Resources Information Center
Binder, Marni
2011-01-01
This article draws from a larger study that examines the multiple literacies inherent in children's drawings. The author discusses a qualitative research project conducted with a split grade one and two classroom in Toronto, Canada. She argues that pictorial images can be read as a form of literacy, where thought is made public through visual…
Effects of Discrete Emotions on Young Children's Ability to Discern Fantasy and Reality
ERIC Educational Resources Information Center
Carrick, Nathalie; Quas, Jodi A.
2006-01-01
This study examined 3- to 5-year-olds' (N = 128; 54% girls) ability to discriminate emotional fantasy and reality. Children viewed images depicting fantastic or real events that elicited several emotions, reported whether each event could occur, and rated their emotional reaction to the image. Children were also administered the Play Behavior…
ERIC Educational Resources Information Center
Shukla, Dinesh K.; Keehn, Brandon; Lincoln, Alan J.; Muller, Ralph-Axel
2010-01-01
Objective: Autism spectrum disorder (ASD) is increasingly viewed as a disorder of functional networks, highlighting the importance of investigating white matter and interregional connectivity. We used diffusion tensor imaging (DTI) to examine white matter integrity for the whole brain and for corpus callosum, internal capsule, and middle…
ERIC Educational Resources Information Center
Wiseman, Marcie C.; Moradi, Bonnie
2010-01-01
On the basis of integrating objectification theory research with research on body image and eating problems among sexual minority men, the present study examined relations among sociocultural and psychological correlates of eating disorder symptoms with a sample of 231 sexual minority men. Results of a path analysis supported tenets of…
Effects of Ocular Optics on Perceived Visual Direction and Depth
NASA Astrophysics Data System (ADS)
Ye, Ming
Most studies of human retinal image quality have specifically addressed the issues of image contrast, few have examined the problem of image location. However, one of the most impressive properties of human vision involves the location of objects. We are able to identify object location with great accuracy (less than 5 arcsec). The sensitivity we exhibit for image location indicates that any optical errors, such as refractive error, ocular aberrations, pupil decentration, etc., may have noticeable effects on perceived visual direction and distance of objects. The most easily observed effects of these optical factors is a binocular depth illusion called chromostereopsis in which equidistance colored objects appear to lie at the different distances. This dissertation covers a series of theoretical and experimental studies that examined the effects of ocular optics on perceived monocular visual direction and binocular chromostereopsis. Theoretical studies included development of an adequate eye model for predicting chromatic aberration, a major ocular aberration, using geometric optics. Also, a wave optical analysis is used to model the effects of defocus, optical aberrations, Stiles-Crawford effect (SCE) and pupil location on retinal image profiles. Experimental studies used psychophysical methods such as monocular vernier alignment tests, binocular stereoscopic tests, etc. This dissertation concludes: (1) With a decentered large pupil, the SCE reduces defocused image shifts compare to an eye without the SCE. (2) The blurred image location can be predicted by the centroid of the image profile. (3) Chromostereopsis with small pupils can be precisely accounted for by the interocular difference in monocular transverse chromatic aberration. (4) The SCE also plays an important role in the effect of pupil size on chromostereopsis. The reduction of chromostereopsis with large pupils can be accurately predicted by the interocular difference in monocular chromatic diplopia which is also reduced with large pupils. This supports the hypothesis that the effect of pupil size on chromostereopsis is due to monocular mechanisms.
Feasibility Study of Compton Cameras for X-ray Fluorescence Computed Tomography with Humans
Vernekohl, Don; Ahmad, Moiz; Chinn, Garry; Xing, Lei
2017-01-01
X-ray fluorescence imaging is a promising imaging technique able to depict the spatial distributions of low amounts of molecular agents in vivo. Currently, the translation of the technique to preclinical and clinical applications is hindered by long scanning times as objects are scanned with flux-limited narrow pencil beams. The study presents a novel imaging approach combining x-ray fluorescence imaging with Compton imaging. Compton cameras leverage the imaging performance of XFCT and abolish the need of pencil beam excitation. The study examines the potential of this new imaging approach on the base of Monte-Carlo simulations. In the work, it is first presented that the particular option of slice/fan-beam x-ray excitation has advantages in image reconstruction in regard of processing time and image quality compared to traditional volumetric Compton imaging. In a second experiment, the feasibility of the approach for clinical applications with tracer agents made from gold nano-particles is examined in a simulated lung scan scenario. The high energy of characteristic x-ray photons from gold is advantageous for deep tissue penetration and has lower angular blurring in the Compton camera. It is found that Doppler broadening in the first detector stage of the Compton camera adds the largest contribution on the angular blurring; physically limiting the spatial resolution. Following the analysis of the results from the spatial resolution test, resolutions in the order of one centimeter are achievable with the approach in the center of the lung. The concept of Compton imaging allows to distinguish to some extend between scattered photons and x-ray fluorescent photons based on their difference in emission position. The results predict that molecular sensitivities down to 240 pM/l for 5 mm diameter lesions at 15 mGy for 50 nm diameter gold nano-particles are achievable. A 45-fold speed up time for data acquisition compared to traditional pencil beam XFCT could be achieved for lung imaging on cost of a small sensitivity decrease. PMID:27845933
Evaluation of MRI-US Fusion Technology in Sports-Related Musculoskeletal Injuries.
Wong-On, Manuel; Til-Pérez, Lluís; Balius, Ramón
2015-06-01
A combination of magnetic resonance imaging (MRI) with real-time high-resolution ultrasound (US) known as fusion imaging may improve visualization of musculoskeletal (MSK) sports medicine injuries. The aim of this study was to evaluate the applicability of MRI-US fusion technology in MSK sports medicine. This study was conducted by the medical services of the FC Barcelona. The participants included volunteers and referred athletes with symptomatic and asymptomatic MSK injuries. All cases underwent MRI which was loaded into the US system for manual registration on the live US image and fusion imaging examination. After every test, an evaluation form was completed in terms of advantages, disadvantages, and anatomic fusion landmarks. From November 2014 to March 2015, we evaluated 20 subjects who underwent fusion imaging, 5 non-injured volunteers and 15 injured athletes, 11 symptomatic and 4 asymptomatic, age range 16-50 years, mean 22. We describe some of the anatomic landmarks used to guide fusion in different regions. This technology allowed us to examine muscle and tendon injuries simultaneously in US and MRI, and the correlation of both techniques, especially low-grade muscular injuries. This has also helped compensate for the limited field of view with US. It improves spatial orientation of cartilage, labrum and meniscal injuries. However, a high-quality MRI image is essential in achieving an adequate fusion image, and 3D sequences need to be added in MRI protocols to improve navigation. The combination of real-time MRI and US image fusion and navigation is relatively easy to perform and is helping to improve understanding of MSK injuries. However, it requires specific skills in MSK imaging and still needs further research in sports-related injuries. Toshiba Medical Systems Corporation.
Long-range non-contact imaging photoplethysmography: cardiac pulse wave sensing at a distance
NASA Astrophysics Data System (ADS)
Blackford, Ethan B.; Estepp, Justin R.; Piasecki, Alyssa M.; Bowers, Margaret A.; Klosterman, Samantha L.
2016-03-01
Non-contact, imaging photoplethysmography uses photo-optical sensors to measure variations in light absorption, caused by blood volume pulsations, to assess cardiopulmonary parameters including pulse rate, pulse rate variability, and respiration rate. Recently, researchers have studied the applications and methodology of imaging photoplethysmography. Basic research has examined some of the variables affecting data quality and accuracy of imaging photoplethysmography including signal processing, imager parameters (e.g. frame rate and resolution), lighting conditions, subject motion, and subject skin tone. This technology may be beneficial for long term or continuous monitoring where contact measurements may be harmful (e.g. skin sensitivities) or where imperceptible or unobtrusive measurements are desirable. Using previously validated signal processing methods, we examined the effects of imager-to-subject distance on one-minute, windowed estimates of pulse rate. High-resolution video of 22, stationary participants was collected using an enthusiast-grade, mirrorless, digital camera equipped with a fully-manual, super-telephoto lens at distances of 25, 50, and 100 meters with simultaneous contact measurements of electrocardiography, and fingertip photoplethysmography. By comparison, previous studies have usually been conducted with imager-to-subject distances of up to only a few meters. Mean absolute error for one-minute, windowed, pulse rate estimates (compared to those derived from gold-standard electrocardiography) were 2.0, 4.1, and 10.9 beats per minute at distances of 25, 50, and 100 meters, respectively. Long-range imaging presents several unique challenges among which include decreased, observed light reflectance and smaller regions of interest. Nevertheless, these results demonstrate that accurate pulse rate measurements can be obtained from over long imager-to-participant distances given these constraints.
Fazzino, Tera L; Hunter, Rebecca Clausius; Sporn, Nora; Christifano, Danielle N; Befort, Christie A
2017-03-01
Obesity and weight gain after breast cancer treatment are common among survivors, yet the relationship between weight and body image has received little attention. The purpose of the current study was to examine the relationship between current body mass index, weight gain since diagnosis, and largest weight fluctuation in adulthood with six dimensions of body image among overweight/obese breast cancer survivors. The current study used data obtained from a weight control trial with 210 rural overweight/obese breast cancer survivors. Using data collected at baseline, multiple regression models were constructed to examine the relative association of the three weight variables with breast cancer-specific dimensions of body image while controlling for demographic characteristics and cancer treatment-related variables. Largest weight fluctuation in adulthood significantly predicted overall body image (p = 0.01) and was associated with the three socially oriented dimensions of body image: social activity restriction, embarrassment about appearance, and sexuality (all ps = 0.01). Weight gain since diagnosis approached statistical significance in predicting overall body image (p = 0.05) and was associated with embarrassment about appearance (p = 0.03). Current body mass index was not significantly associated with overall body image when controlling for the other weight variables (p = 0.07) and was negatively associated with social activity restriction (p = 0.01) and sexuality (p = 0.01). Obese breast cancer survivors with a history of a large weight fluctuation in adulthood may be prone to poorer breast cancer-specific body image several years after treatment. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Primary postural instability: a cause of recurrent sudden falls in the elderly.
Djaldetti, R; Lorberboym, M; Melamed, E
2006-12-01
Elderly patients with recurrent falls are frequently diagnosed with an extrapyramidal syndrome. This study aims to characterise a distinct group of patients with recurrent falls and postural instability as a hallmark of the clinical examination. The study took place in the Movement Disorders Unit, Rabin Medical Center, Petah Tiqva, Israel among 26 patients with recurrent falls who had no clinical evidence of a neurodegenerative disease. Medical records, neurological examination and brain imaging studies were assessed. Falls in these patients were sudden, unprovoked, with no vertigo or loss of consciousness. All had postural instability with minimal or no abnormality on the neurological examination. Brain imaging showed diffuse ischaemic changes in 65%. [(123)I]-FPCIT SPECT with the dopamine transporter ligand, performed in five patients, was normal in all. Recurrent falls might be caused by a neurological syndrome that primarily affects balance control. The importance of identifying this disorder is its distinction from other parkinsonian syndromes causing falls.
Hayashi, Takashi; Iwai, Mitsuhiro; Takahashi, Katsuhiko; Takeda, Satoshi; Tateishi, Toshiki; Kaneko, Rumi; Ogasawara, Yoko; Yonezawa, Kazuya; Hanada, Akiko
2011-01-01
Using a 3D-imaging-create-function server and network services by IP-VPN, we began to deliver 3D images to the remote institution. An indication trial of the primary image, a rotary trial of a 3D image, and a reproducibility trial were studied in order to examine the practicality of using the system in a real network between Hakodate and Sapporo (communication distance of about 150 km). In these trials, basic data (time and receiving data volume) were measured for every variation of QF (quality factor) or monitor resolution. Analyzing the results of the system using a 3D image delivery server of our hospital with variations in the setting of QF and monitor resolutions, we concluded that this system has practicality in the remote interpretation-of-radiogram work, even if the access point of the region has a line speed of 6 Mbps.
Ex vivo imaging of early dental caries within the interproximal space
NASA Astrophysics Data System (ADS)
Choo-Smith, Lin-P'ing; Hewko, Mark D.; Dufour, Marc L.; Fulton, Crystal; Qiu, Pingli; Gauthier, Bruno; Padioleau, Christian; Bisaillon, Charles-Etienne; Dong, Cecilia; Cleghorn, Blaine M.; Lamouche, Guy; Sowa, Michael G.
2009-02-01
Optical coherence tomography (OCT) is emerging as a technology that can potentially be used for the detection and monitoring of early dental enamel caries since it can provide high-resolution depth imaging of early lesions. To date, most caries detection optical technologies are well suited for examining caries at facial, lingual, incisal and occlusal surfaces. The approximal surfaces between adjacent teeth are difficult to examine due to lack of visual access and limited space for these new caries detection tools. Using a catheter-style probe developed at the NRC-Industrial Materials Institute, the probe was inserted into the interproximal space to examine the approximal surfaces with OCT imaging at 1310 nm. The probe was rotated continuously and translated axially to generate depth images in a spiral fashion. The probe was used in a mock tooth arch model consisting of extracted human teeth mounted with dental rope wax in their anatomically correct positions. With this ex vivo model, the probe provided images of the approximal surfaces revealing morphological structural details, regions of calculus, and especially regions of early dental caries (white spot lesions). Results were compared with those obtained from OCT imaging of individual samples where the approximal surfaces of extracted teeth are accessible on a lab-bench. Issues regarding access, regions of interest, and factors to be considered in an in vivo setting will be discussed. Future studies are aimed at using the probe in vivo with patient volunteers.
What's color got to do with it? The influence of color on visual attention in different categories.
Frey, Hans-Peter; Honey, Christian; König, Peter
2008-10-23
Certain locations attract human gaze in natural visual scenes. Are there measurable features, which distinguish these locations from others? While there has been extensive research on luminance-defined features, only few studies have examined the influence of color on overt attention. In this study, we addressed this question by presenting color-calibrated stimuli and analyzing color features that are known to be relevant for the responses of LGN neurons. We recorded eye movements of 15 human subjects freely viewing colored and grayscale images of seven different categories. All images were also analyzed by the saliency map model (L. Itti, C. Koch, & E. Niebur, 1998). We find that human fixation locations differ between colored and grayscale versions of the same image much more than predicted by the saliency map. Examining the influence of various color features on overt attention, we find two extreme categories: while in rainforest images all color features are salient, none is salient in fractals. In all other categories, color features are selectively salient. This shows that the influence of color on overt attention depends on the type of image. Also, it is crucial to analyze neurophysiologically relevant color features for quantifying the influence of color on attention.
Simultaneous imaging of oxygen tension and blood flow in animals using a digital micromirror device.
Ponticorvo, Adrien; Dunn, Andrew K
2010-04-12
In this study we present a novel imaging method that combines high resolution cerebral blood flow imaging with a highly flexible map of absolute pO(2). In vivo measurements of pO(2) in animals using phosphorescence quenching is a well established method, and is preferable over electrical probes which are inherently invasive and are limited to single point measurements. However, spatially resolved pO(2) measurements using phosphorescence lifetime quenching typically require expensive cameras to obtain images of pO(2) and often suffer from poor signal to noise. Our approach enables us to retain the high temporal resolution and sensitivity of single point detection of phosphorescence by using a digital micromirror device (DMD) to selectively illuminate arbitrarily shaped regions of tissue. In addition, by simultaneously using Laser Speckle Contrast Imaging (LSCI) to measure relative blood flow, we can better examine the relationship between blood flow and absolute pO(2). We successfully used this instrument to study changes that occur during ischemic conditions in the brain with enough spatial resolution to clearly distinguish different regions. This novel instrument will provide researchers with an inexpensive and improved technique to examine multiple hemodynamic parameters simultaneously in the brain as well as other tissues.
Mollard, Séverine; Fanciullino, Raphaelle; Giacometti, Sarah; Serdjebi, Cindy; Benzekry, Sebastien; Ciccolini, Joseph
2016-01-01
This study aimed at evaluating the reliability and precision of Diffuse Luminescent Imaging Tomography (DLIT) for monitoring primary tumor and metastatic spreading in breast cancer mice, and to develop a biomathematical model to describe the collected data. Using orthotopic mammary fat pad model of breast cancer (MDAMB231-Luc) in mice, we monitored tumor and metastatic spreading by three-dimensional (3D) bioluminescence and cross-validated it with standard bioluminescence imaging, caliper measurement and necropsy examination. DLIT imaging proved to be reproducible and reliable throughout time. It was possible to discriminate secondary lesions from the main breast cancer, without removing the primary tumor. Preferential metastatic sites were lungs, peritoneum and lymph nodes. Necropsy examinations confirmed DLIT measurements. Marked differences in growth profiles were observed, with an overestimation of the exponential phase when using a caliper as compared with bioluminescence. Our mathematical model taking into account the balance between living and necrotic cells proved to be able to reproduce the experimental data obtained with a caliper or DLIT imaging, because it could discriminate proliferative living cells from a more composite mass consisting of tumor cells, necrotic cell, or inflammatory tissues. DLIT imaging combined with mathematical modeling could be a powerful and informative tool in experimental oncology. PMID:27812027
A body image and disordered eating intervention for women in midlife: a randomized controlled trial.
McLean, Siân A; Paxton, Susan J; Wertheim, Eleanor H
2011-12-01
This study examined the outcome of a body image and disordered eating intervention for midlife women. The intervention was specifically designed to address risk factors that are pertinent in midlife. Participants were 61 women aged 30 to 60 years (M = 43.92, SD = 8.22) randomly assigned to intervention (n = 32) or (delayed treatment) control (n = 29) groups. Following an 8-session facilitated group cognitive behavioral therapy-based intervention, outcomes from the Body Shape Questionnaire; Eating Disorder Examination Questionnaire; Body Image Avoidance Questionnaire; Physical Appearance Comparison Scale; Sociocultural Attitudes Towards Appearance Scale, Internalization subscale; measures of appearance importance, cognitive reappraisal, and self-care; Dutch Eating Behavior Questionnaire; and Kessler Psychological Distress Scale were compared for statistical and clinical significance from baseline to posttest and 6-month follow-up. Following the intent-to-treat principle, mixed-model analyses with a mixed within-between design demonstrated that the intervention group had large improvements that were statistically significantly different from the control group in body image, disordered eating, and risk factor variables and that were maintained at 6-month follow-up. Furthermore, the improvements were also of clinical importance. This study provides support for the efficacy of an intervention to reduce body image and eating concerns in midlife women. Further research into interventions tailored for this population is warranted.
Swami, Viren; Kannan, Kumaraswami; Furnham, Adrian
2012-11-01
Previous studies examining body image from a cross-cultural perspective have tended to neglect samples from different ethnic groups or along a rural-urban continuum. To overcome this limitation, the present study examined positive body image among rural and urban women from three major indigenous ethnic groups in Sabah, Malaysia. A total of 202 women completed the Body Appreciation Scale, as well as measures of media exposure and financial security, and provided their demographic details. s showed that there were significant rural-urban differences in body appreciation, with rural participants having significantly higher body appreciation than urban participants. A comparison with a previous data set of West Malaysian women (Swami & Chamorro-Premuzic, 2008) showed that the current urban sample had significantly lower body appreciation and that the rural group had significantly higher body appreciation. Further results showed that research site (urban vs rural) explained 11.0% of the variance in body appreciation. Participant body mass index and exposure to western forms of media explained an additional 2.0% of the variance. These results suggest that there are differences in body image between rural and urban women. Results are discussed in relation to the promotion of positive body image, particularly in developing societies where health care resources may be limited.
History and Physical Examination for Shoulder Instability.
Haley, Col Chad A
2017-09-01
Glenohumeral instability frequently occurs in young active individuals especially those engaged in athletic and military activities. With advanced imaging and arthroscopic evaluation, our understanding of the injury patterns associated with instability has significantly improved. The majority of instability results from a traumatic anterior event which presents with common findings in the history, examination, and imaging studies. As such, a comprehensive evaluation of the patient is important to correctly diagnose the instability patterns and thus provide appropriate treatment intervention. With the correct diagnosis and improved surgical techniques, the majority of patients with instability can return to preinjury levels.
/sup 99m/Tc-methylene diphosphonate bone imaging in the evaluation of total hip prostheses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weiss, P.E.; Mall, J.C.; Hoffer, P.B.
1979-12-01
A retrospective study was performed to determine the accuracy of /sup 99m/Tc-methylene diphosphonate bone imaging in the evaluation of total hip arthroplasty for loosening and/or infection. Using focally increased activity at the tip of the femoral component or in the region of the acetabular component as a criterion, the examination was 77% specific and 100% sensitive for loosening and/or infection. A possible explanation for the increased uptake at the tip of the femoral component and the role of this examination in the management of a painful total hip prosthesis are discussed.
Infrared imaging enhances retinal crystals in Bietti's crystalline dystrophy.
Brar, Vikram S; Benson, William H
2015-01-01
Infrared imaging dramatically increased the number of crystalline deposits visualized compared with clinical examination, standard color fundus photography, and red free imaging in patients with Bietti's crystalline dystrophy. We believe that this imaging modality significantly improves the sensitivity with which these lesions are detected, facilitating earlier diagnosis and may potentially serve as a prognostic indicator when examined over time.
Launay, F; Barrau, K; Petit, P; Jouve, J-L; Auquier, P; Bollini, G
2008-09-01
Appropriate assessment of ankle injuries in children and adolescents is a common emergency room problem. Many imaging techniques have been proposed, but with no consensus on the reality of anatomic lesions in ankles free of fractures, complicating the therapeutic decision. We analyzed the lesions observed with magnetic resonance imaging (MRI) in a large number of acute ankles in children. This prospective study was conducted in a pediatric emergency room. The study population included all children aged eight to 15 years who presented an isolated injury of the ankle without fracture on the plain x-ray. History taking and physical examination were standardized. MRI was performed within three days of the initial physical examination. All the radiographic documents were examined by an experienced radiologist blinded to the results of the physical examination. During the study period, 116 patients were included. One hundred two MRI series were examined. Minor ligament injury was noted in 20 patients and ligament tear in five, including three with a closed distal tibial growth plate. Minor bone injury was noted in 42 patients and fracture in seven. None of these fractures were visible on the plain x-ray, even after knowledge of the MRI. Injuries were more frequent in boys. Injuries were more frequent when the pain was localized on the lateral aspect of the ankle and when there was an edema. Despite an abundant literature on ankle sprains, prospective studies are scarce in the pediatric population. We have found that MRI is particularly well-adapted for children because it allows a complete examination of anatomic lesions involving the bone or ligaments without the inconveniences of injections, pain, or radiation. Our clinical and imaging findings show that ankle sprains are real in children. We were however unable to identify any clinical factors predictive of ligament and/or bone injury. Other studies should be conducted to better understand the nosological context of ankle sprain in children and adolescents. Further study will enable a better evidence-based approach to individually adapted therapy.
Sayah, Anousheh; Jay, Ann K; Toaff, Jacob S; Makariou, Erini V; Berkowitz, Frank
2016-09-01
Reducing lumbar spine MRI scanning time while retaining diagnostic accuracy can benefit patients and reduce health care costs. This study compares the effectiveness of a rapid lumbar MRI protocol using 3D T2-weighted sampling perfection with application-optimized contrast with different flip-angle evolutions (SPACE) sequences with a standard MRI protocol for evaluation of lumbar spondylosis. Two hundred fifty consecutive unenhanced lumbar MRI examinations performed at 1.5 T were retrospectively reviewed. Full, rapid, and complete versions of each examination were interpreted for spondylotic changes at each lumbar level, including herniations and neural compromise. The full examination consisted of sagittal T1-weighted, T2-weighted turbo spin-echo (TSE), and STIR sequences; and axial T1- and T2-weighted TSE sequences (time, 18 minutes 40 seconds). The rapid examination consisted of sagittal T1- and T2-weighted SPACE sequences, with axial SPACE reformations (time, 8 minutes 46 seconds). The complete examination consisted of the full examination plus the T2-weighted SPACE sequence. Sensitivities and specificities of the full and rapid examinations were calculated using the complete study as the reference standard. The rapid and full studies had sensitivities of 76.0% and 69.3%, with specificities of 97.2% and 97.9%, respectively, for all degenerative processes. Rapid and full sensitivities were 68.7% and 66.3% for disk herniation, 85.2% and 81.5% for canal compromise, 82.9% and 69.1% for lateral recess compromise, and 76.9% and 69.7% for foraminal compromise, respectively. Isotropic SPACE T2-weighted imaging provides high-quality imaging of lumbar spondylosis, with multiplanar reformatting capability. Our SPACE-based rapid protocol had sensitivities and specificities for herniations and neural compromise comparable to those of the protocol without SPACE. This protocol fits within a 15-minute slot, potentially reducing costs and discomfort for a large subgroup of patients.
Advanced Imaging Adds Little Value in the Diagnosis of Femoroacetabular Impingement Syndrome.
Cunningham, Daniel J; Paranjape, Chinmay S; Harris, Joshua D; Nho, Shane J; Olson, Steven A; Mather, Richard C
2017-12-20
Femoroacetabular impingement (FAI) syndrome is an increasingly recognized source of hip pain and disability in young active adults. In order to confirm the diagnosis, providers often supplement physical examination maneuvers and radiographs with intra-articular hip injection, magnetic resonance imaging (MRI), or magnetic resonance arthrography (MRA). Since diagnostic imaging represents the fastest rising cost segment in U.S. health care, there is a need for value-driven diagnostic algorithms. The purpose of this study was to identify cost-effective diagnostic strategies for symptomatic FAI, comparing history and physical examination (H&P) alone (utilizing only radiographic imaging) with supplementation with injection, MRI, or MRA. A simple-chain decision model run as a cost-utility analysis was constructed to assess the diagnostic value of the MRI, MRA, and injection that are added to the H&P and radiographs in diagnosing symptomatic FAI. Strategies were compared using the incremental cost-utility ratio (ICUR) with a willingness to pay (WTP) of $100,000/QALY (quality-adjusted life year). Direct costs were measured using the Humana database (PearlDiver). Diagnostic test accuracy, treatment outcome probabilities, and utilities were extracted from the literature. H&P with and without supplemental diagnostic injection was the most cost-effective. Adjunct injection was preferred in situations with a WTP of >$60,000/QALY, low examination sensitivity, and high FAI prevalence. With low disease prevalence and low examination sensitivity, as may occur in a general practitioner's office, H&P with injection was the most cost-effective strategy, whereas in the reciprocal scenario, H&P with injection was only favored at exceptionally high WTP (∼$990,000). H&P and radiographs with supplemental diagnostic injection are preferred over advanced imaging, even with reasonable deviations from published values of disease prevalence, test sensitivity, and test specificity. Providers with low examination sensitivity in situations with low disease prevalence may benefit most from including injection in their diagnostic strategy. Providers with high examination sensitivity in situations with high disease prevalence may not benefit from including injection in their diagnostic strategy. Providers should not routinely rely on advanced imaging to diagnose FAI syndrome, although advanced imaging may have a role in challenging clinical scenarios. Economic and Decision Analysis Level IV. See Instructions for Authors for a complete description of levels of evidence.
Minority Images: A Project Guide.
ERIC Educational Resources Information Center
Murphy, Sharon; Estrada, Paula
The reading list and assignments in this study guide are designed to involve high school students in examining the media from a nonwhite perspective. The beginning assignments require students to assemble their own bibliography relating to minority groups in the media, to examine the lives and contributions of specific Chicano, black, and American…
Rosenkrantz, Andrew B; Liang, Yu; Duszak, Richard; Recht, Michael P
2017-08-01
Patients' willingness to travel farther distances for certain imaging services may reflect their perceptions of the degree of differentiation of such services. We compare patients' travel times for a range of imaging examinations performed across a large academic health system. We searched the NYU Langone Medical Center Enterprise Data Warehouse to identify 442,990 adult outpatient imaging examinations performed over a recent 3.5-year period. Geocoding software was used to estimate typical driving times from patients' residences to imaging facilities. Variation in travel times was assessed among examination types. The mean expected travel time was 29.2 ± 20.6 minutes, but this varied significantly (p < 0.001) among examination types. By modality, travel times were shortest for ultrasound (26.8 ± 18.9) and longest for positron emission tomography-computed tomography (31.9 ± 21.5). For magnetic resonance imaging, travel times were shortest for musculoskeletal extremity (26.4 ± 19.2) and spine (28.6 ± 21.0) examinations and longest for prostate (35.9 ± 25.6) and breast (32.4 ± 22.3) examinations. For computed tomography, travel times were shortest for a range of screening examinations [colonography (25.5 ± 20.8), coronary artery calcium scoring (26.1 ± 19.2), and lung cancer screening (26.4 ± 14.9)] and longest for angiography (32.0 ± 22.6). For ultrasound, travel times were shortest for aortic aneurysm screening (22.3 ± 18.4) and longest for breast (30.1 ± 19.2) examinations. Overall, men (29.9 ± 21.6) had longer (p < 0.001) travel times than women (27.8 ± 20.3); this difference persisted for each modality individually (p ≤ 0.006). Patients' willingness to travel longer times for certain imaging examination types (particularly breast and prostate imaging) supports the role of specialized services in combating potential commoditization of imaging services. Disparities in travel times by gender warrant further investigation. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Synchrotron radiation microimaging in rabbit models of cancer for preclinical testing
NASA Astrophysics Data System (ADS)
Umetani, Keiji; Uesugi, Kentaro; Kobatake, Makito; Yamamoto, Akira; Yamashita, Takenori; Imai, Shigeki
2009-10-01
Preclinical laboratory animal imaging modalities such as microangiography and micro-computed tomography (micro-CT) have been developed at the SPring-8 BL20B2 bending magnet beamline. The objective of this paper is to demonstrate the usefulness of microangiography systems for physiological examinations of live animals and micro-CT systems for postmortem morphological examinations. Synchrotron radiation microangiography and micro-CT with contrast agents present the main advantageous capability of depicting the anatomy of small blood vessels with tens of micrometers' diameter. This paper reports two imaging instrument types and their respective applications to preclinical imaging of tumor angiogenic blood vessels in tumor-bearing rabbits, where tumor angiogenesis is characterized morphologically by an increased number of blood vessels. A microangiography system with spatial resolution around 10 μm has been used for therapeutically evaluating angiogenic vessels in a rabbit model of cancer for evaluating embolization materials in transcatheter arterial embolization and for radiation therapy. After an iodine contrast agent was injected into an artery, in vivo imaging was carried out using a high-resolution real-time detector incorporating an X-ray direct-conversion-type SATICON pickup tube. On the other hand, a micro-CT system capably performed three-dimensional visualization of tumor angiogenic blood vessels using tumor-transplanted rabbit specimens with a barium sulfate contrast agent injected into the blood vessels. For specimen imaging, a large-field high-resolution micro-CT system based on a 10-megapixel CCD camera was developed to study tumor-associated alterations in angioarchitecture. Evidence of increased vascularity by tumor angiogenesis and decreased vascularity by tumor treatments was achieved by physiological evaluation of angiogenic small blood vessels in microangiographic imaging and by morphological assessment in micro-CT imaging. These results demonstrate the accuracy and usefulness of microangiography and micro-CT systems for quantitative examination of animals' angioarchitecture, respectively, during live and postmortem examinations.
Velázquez, Maríia Teresa; Albarrán, Agustín; Hernández, Felipe; García Tejada, Julio; Zueco, Javier; Andreu, Javier; De la Torre, Jose-María; Figueroa, Alvaro; Sainz, Fermin; Tascón, Juan
2010-08-01
Mild reductions in iodine concentration could reduce acute side effects after intraarterial contrast media administration without affecting the quality of coronary artery images. This study was designed to show the equivalence in terms of image quality of two nonionic low-osmolar monomers, iobitridol 350 and iopamidol 370, and to compare their clinical safety in coronary angiography and ventriculography. In this multicentre, double-blind clinical trial, 98 adult patients were randomized to receive either iobitridol 350 or iopamidol 370. The image quality (primary evaluation criterion) of the whole examination was assessed using a 5-point scale (poor, fair, moderate, good, excellent). Secondary endpoints were the image quality per territory, diagnostic efficacy, practical comfort (5-point scale: impossible to evaluate, not practical, moderately practical, practical, very practical to use) and clinical safety (adverse events and vital signs). The proportions of examinations presenting with good or excellent global image quality was similar with both contrast media: 87.8% with iobitridol 350 vs. 89.8% with iopamidol 370. Similar results were observed when considering the image quality specifically for each major coronary artery and left ventricle. No difference between groups was found with respect to other secondary criteria. Adverse events occurred in 7 patients with iobitridol 350 (14.3%) and in 10 patients with iopamidol 370 (20.4%). This study showed that, with regard to image quality and diagnostic efficacy and using a lower iodine concentration, iobitridol 350 was comparable to iopamidol 370 in adult patients requiring coronary angiography and ventriculography for diagnostic indications.
Prenatal Brain MR Imaging: Reference Linear Biometric Centiles between 20 and 24 Gestational Weeks.
Conte, G; Milani, S; Palumbo, G; Talenti, G; Boito, S; Rustico, M; Triulzi, F; Righini, A; Izzo, G; Doneda, C; Zolin, A; Parazzini, C
2018-05-01
Evaluation of biometry is a fundamental step in prenatal brain MR imaging. While different studies have reported reference centiles for MR imaging biometric data of fetuses in the late second and third trimesters of gestation, no one has reported them in fetuses in the early second trimester. We report centiles of normal MR imaging linear biometric data of a large cohort of fetal brains within 24 weeks of gestation. From the data bases of 2 referral centers of fetal medicine, accounting for 3850 examinations, we retrospectively collected 169 prenatal brain MR imaging examinations of singleton pregnancies, between 20 and 24 weeks of gestational age, with normal brain anatomy at MR imaging and normal postnatal neurologic development. To trace the reference centiles, we used the CG-LMS method. Reference biometric centiles for the developing structures of the cerebrum, cerebellum, brain stem, and theca were obtained. The overall interassessor agreement was adequate for all measurements. Reference biometric centiles of the brain structures in fetuses between 20 and 24 weeks of gestational age may be a reliable tool in assessing fetal brain development. © 2018 by American Journal of Neuroradiology.
Nechifor-Boilă, I A; Bancu, S; Buruian, M; Charlot, M; Decaussin-Petrucci, M; Krauth, J-S; Nechifor-Boilă, A C; Borda, A
2013-01-01
Dynamic Contrast-Enhanced Magnetic Resonance Mammography (DCE-MRM) represents the most sensitive examination for breast cancer (BC) diagnosis. However literature data reports very inhomogeneous specificity. The aim of our study was to evaluate the clinical efficiency of a new MRM technique - diffusion weighted imaging with background body signal suppression T2 image fusion in BC diagnosis, compared to DCE-MRM. We retrospectively analyzed 50 consecutive DCE-MRM examinations with DWIBS sequence from the archives of the Department of Radiology, Lyon Sud Hospital, (02.2010- 02.2011), summing up to 64 breast lesions. Fusions were created using the Osirix software from the DWIBS images (b=1000 s mm2) and their T2 correspondents. Interpretation was performed using an adapted BI-RADS system. The final histopathological examination or a minimum 6-months follow-up served as gold standard. Out of the 64 examined breast lesions, 35(54.7%) were classified as malignant by DCE-MRM and 24(37.5%) cases by DWIBS T2, respectively. Thus the DWIBS T2 fusion had a Sensitivity of 62.5%(95%CI:35.4-84.8) and a Specificity of 70.8%(95%CI:55.9-83.3) while DCE-MRM had a higher Sensitivity: 87.5%(95%CI:61.6-98.4) but a lower Specificity: 56.2%(95%CI:41.1-70.5). DWIBS T2 fusion is an innovative MRM technique, with a specificity superior to DCE-MRM, showing a large potential for improving the clinical efficiency of classical MRM. Celsius.
Borba, Flávia de Souza Lins; Jawhari, Tariq; Saldanha Honorato, Ricardo; de Juan, Anna
2017-03-27
This article describes a non-destructive analytical method developed to solve forensic document examination problems involving crossed lines and obliteration. Different strategies combining confocal Raman imaging and multivariate curve resolution-alternating least squares (MCR-ALS) are presented. Multilayer images were acquired at subsequent depth layers into the samples. It is the first time that MCR-ALS is applied to multilayer images for forensic purposes. In this context, this method provides a single set of pure spectral ink signatures and related distribution maps for all layers examined from the sole information in the raw measurement. Four cases were investigated, namely, two concerning crossed lines with different degrees of ink similarity and two related to obliteration, where previous or no knowledge about the identity of the obliterated ink was available. In the crossing line scenario, MCR-ALS analysis revealed the ink nature and the chronological order in which strokes were drawn. For obliteration cases, results making active use of information about the identity of the obliterated ink in the chemometric analysis were of similar quality as those where the identity of the obliterated ink was unknown. In all obliteration scenarios, the identity of inks and the obliterated text were satisfactorily recovered. The analytical methodology proposed is of general use for analytical forensic document examination problems, and considers different degrees of complexity and prior available information. Besides, the strategies of data analysis proposed can be applicable to any other kind of problem in which multilayer Raman images from multicomponent systems have to be interpreted.
2012-01-01
Background Increasingly, neonatal clinics seek to minimize painful experiences and stress for premature infants. Fundoscopy performed with a binocular indirect ophthalmoscope is the reference examination technique for screening of retinopathy of prematurity (ROP), and it is associated with pain and stress. Wide-field digital retinal imaging is a recent technique that should be evaluated for minimizing infant pain and stress. Methods The purpose of the study was to assess and compare the impact of using a binocular indirect ophthalmoscope (BIO), or wide-field digital retinal imaging (WFDRI) on pain and stress in infants undergoing ROP screening examination. This was a comparative evaluation study of two screening procedures. Ophthalmologic examinations (N = 70) were performed on 24 infants with both BIO and WFDRI. Pain assessments were performed with two specific neonatal scales (Crying, requires oxygen, increased vital signs, expression and sleeplessness, CRIES and, Premature infant pain profile, PIPP) just prior to the examination, and 30 seconds, 1 hour, and 24 hours later after ending the examination. Results Changes over time were significantly different between BIO and WFDRI with both scales (PIPP score, p = .007, and CRIES score, p = .001). Median PIPP score (interquartile interval) at baseline was 4 (3–5). At 30 seconds the score was 8 (6–9) for BIO and 6 (5–7) for WFDRI, respectively. The increase in PIPP score between baseline and 30 seconds was significantly lower with WFDRI (p = .006). The median increase in CRIES score from baseline to 30 seconds was 1 point lower for WFDRI than for BIO (p < .001). No significant difference in response remained at 1 hour or 24 hour assessments. Conclusions A transient short-term pain and stress response occurs with both BIO and WFDRI. Infants examined for screening of ROP with digital retinal imaging present less pain and stress at 30 seconds following completion of the exam when compared with binocular indirect ophthalmoscopy. PMID:22928523
Biwasaka, Hitoshi; Saigusa, Kiyoshi; Aoki, Yasuhiro
2005-03-01
In this study, the applicability of holography in the 3-dimensional recording of forensic objects such as skulls and mandibulae, and the accuracy of the reconstructed 3-D images, were examined. The virtual holographic image, which records the 3-dimensional data of the original object, is visually observed on the other side of the holographic plate, and reproduces the 3-dimensional shape of the object well. Another type of holographic image, the real image, is focused on a frosted glass screen, and cross-sectional images of the object can be observed. When measuring the distances between anatomical reference points using an image-processing software, the average deviations in the holographic images as compared to the actual objects were less than 0.1 mm. Therefore, holography could be useful as a 3-dimensional recording method of forensic objects. Two superimposition systems using holographic images were examined. In the 2D-3D system, the transparent virtual holographic image of an object is directly superimposed onto the digitized photograph of the same object on the LCD monitor. On the other hand, in the video system, the holographic image captured by the CCD camera is superimposed onto the digitized photographic image using a personal computer. We found that the discrepancy between the outlines of the superimposed holographic and photographic dental images using the video system was smaller than that using the 2D-3D system. Holography seemed to perform comparably to the computer graphic system; however, a fusion with the digital technique would expand the utility of holography in superimposition.
NASA Astrophysics Data System (ADS)
Huang, Kai-Wen; Chieh, Jen-Jie; Lin, In-Tsang; Horng, Herng-Er; Yang, Hong-Chang; Hong, Chin-Yih
2013-10-01
Although the biomarker carcinoembryonic antigen (CEA) is expressed in colorectal tumors, the utility of an anti-CEA-functionalized image medium is powerful for in vivo positioning of colorectal tumors. With a risk of superparamagnetic iron oxide nanoparticles (SPIONPs) that is lower for animals than other material carriers, anti-CEA-functionalized SPIONPs were synthesized in this study for labeling colorectal tumors by conducting different preoperatively and intraoperatively in vivo examinations. In magnetic resonance imaging (MRI), the image variation of colorectal tumors reached the maximum at approximately 24 h. However, because MRI requires a nonmetal environment, it was limited to preoperative imaging. With the potentiality of in vivo screening and intraoperative positioning during surgery, the scanning superconducting-quantum-interference-device biosusceptometry (SSB) was adopted, showing the favorable agreement of time-varied intensity with MRI. Furthermore, biological methodologies of different tissue staining methods and inductively coupled plasma (ICP) yielded consistent results, proving that the obtained in vivo results occurred because of targeted anti-CEA SPIONPs. This indicates that developed anti-CEA SPIONPs owe the utilities as an image medium of these in vivo methodologies.
NASA Astrophysics Data System (ADS)
Davoudi, Bahar; Damodaran, Vani; Bizheva, Kostadinka; Yang, Victor; Dinniwell, Robert; Levin, Wilfred; Vitkin, Alex
2013-03-01
Late oral radiation toxicity is a common condition occurring in a considerable percentage of head and neck cancer patients after radiation therapy which reduces their quality of life. The current examination of these patients is based on a visual inspection of the surface of the oral cavity; however, it is well known that many of the complications start in the subsurface layers before any superficial manifestation. Considering the currently suboptimal examination techniques, we address this clinical problem by using optical coherence tomography (OCT) to monitor the subsurface oral layers with micron-scale resolution images. A spectral-domain OCT system and a specialized oral imaging probe were designed and built for a clinical study to image late oral radiation toxicity patients. In addition to providing qualitative 2D and 3D images of the subsurface oral layers, quantitative metrics were developed to assess the back-scattering and thickness properties of different layers. Metric derivations are explained and preliminary results from late radiation toxicity patients and healthy volunteers are presented and discussed.
Validation of luminescent source reconstruction using spectrally resolved bioluminescence images
NASA Astrophysics Data System (ADS)
Virostko, John M.; Powers, Alvin C.; Jansen, E. D.
2008-02-01
This study examines the accuracy of the Living Image® Software 3D Analysis Package (Xenogen, Alameda, CA) in reconstruction of light source depth and intensity. Constant intensity light sources were placed in an optically homogeneous medium (chicken breast). Spectrally filtered images were taken at 560, 580, 600, 620, 640, and 660 nanometers. The Living Image® Software 3D Analysis Package was employed to reconstruct source depth and intensity using these spectrally filtered images. For sources shallower than the mean free path of light there was proportionally higher inaccuracy in reconstruction. For sources deeper than the mean free path, the average error in depth and intensity reconstruction was less than 4% and 12%, respectively. The ability to distinguish multiple sources decreased with increasing source depth and typically required a spatial separation of twice the depth. The constant intensity light sources were also implanted in mice to examine the effect of optical inhomogeneity. The reconstruction accuracy suffered in inhomogeneous tissue with accuracy influenced by the choice of optical properties used in reconstruction.
NASA Astrophysics Data System (ADS)
Wiyana, T.; Putranto, T. S.; Zulkarnain, A.; Kusdiana, R. N.
2018-03-01
Affective and cognitive image are two main factors that influence destination in Solo. The purpose of this research is to examine the two main factors of Solo towards tourist attraction. The research method is quantitative. Data collected from observation and survey. A total of 113 respondents obtained from accidental sampling method. The results indicate based on cognitive and affective image. Cognitive consists of culture, batik, city tagline, and community. While, affective consists of tradition, culinary, purposes, climate, and welcoming. The findings show that image has weak correlation towards tourist attraction of Solo. It means most of the tourists are not influenced by city image when they choose Solo as one of their travel destination. The differences between primary and minor image are also examined. Research implication is directed for local government to pursue continuous improvement particularly for the branding of Solo.
NASA Astrophysics Data System (ADS)
Toda, Sogo; Kato, Yuji; Kudo, Nobuki; Shimizu, Koichi
2017-04-01
For transillumination imaging of an animal body, we have attempted to suppress the scattering effect in a turbid medium. It is possible to restore the optical image before scattering using phase-conjugate light. We examined the effect of intensity information as well as the phase information for the restoration of the original light distribution. In an experimental analysis using animal tissue, the contributions of the phase- and the intensity-information to the image restoration through turbid medium were demonstrated.
1999-07-01
and lipid vectors, are being tested. Concurrent with the development of procedures for live - cell imaging , we are examining the distribution of proteins...dimensional matrix. These studies have not yet begun. There are a number of procedures that must be developed and perfected in the live - cell imaging , as...components of the Wnt signaling pathway are too preliminary and require additional research prior to publication. (9) CONCLUSIONS Live cell imaging of
NASA Astrophysics Data System (ADS)
André, M. P.; Galperin, M.; Berry, A.; Ojeda-Fournier, H.; O'Boyle, M.; Olson, L.; Comstock, C.; Taylor, A.; Ledgerwood, M.
Our computer-aided diagnostic (CADx) tool uses advanced image processing and artificial intelligence to analyze findings on breast sonography images. The goal is to standardize reporting of such findings using well-defined descriptors and to improve accuracy and reproducibility of interpretation of breast ultrasound by radiologists. This study examined several factors that may impact accuracy and reproducibility of the CADx software, which proved to be highly accurate and stabile over several operating conditions.
Extraneural findings during peripheral nerve ultrasound: Prevalence and further assessment.
Bignotti, Bianca; Zaottini, Federico; Airaldi, Sonia; Martinoli, Carlo; Tagliafico, Alberto
2018-01-01
In this study we evaluated the frequency and further assessment of extraneural findings encountered during peripheral nerve ultrasound (US). Our retrospective review identified 278 peripheral nerve US examinations of 229 patients performed between December 2014 and December 2015. Reports were reviewed to assess the number of studies without peripheral nerve abnormalities and the frequency and further assessment of extraneural findings. A total of 107 peripheral nerve US examinations of 90 patients (49 men and 41 women, mean age 55 ± 16 years) did not report peripheral nerve abnormalities. Extraneural findings were observed in 24 of 107 (22.4%) studies. Fifteen of the 278 [5.4% (95% confidence interval 2.7%-8.1%)] studies led to a recommendation for additional imaging or clinical evaluation of an extraneural finding. At least 5.4% (15 of 278) of peripheral nerve US studies led to additional clinical or imaging assessment. Muscle Nerve 57: 65-69, 2018. © 2017 Wiley Periodicals, Inc.
Frood, R; Baren, J; McDermott, G; Bottomley, D; Patel, C; Scarsbrook, A
2018-04-30
To evaluate the efficacy of single time-point half-body (skull base to thighs) fluorine-18 choline positron emission tomography-computed tomography (PET-CT) compared to a triple-phase acquisition protocol in the detection of prostate carcinoma recurrence. Consecutive choline PET-CT studies performed at a single tertiary referral centre in patients with biochemical recurrence of prostate carcinoma between September 2012 and March 2017 were reviewed retrospectively. The indication for the study, imaging protocol used, imaging findings, whether management was influenced by the PET-CT, and subsequent patient outcome were recorded. Ninety-one examinations were performed during the study period; 42 were carried out using a triple-phase protocol (dynamic pelvic imaging for 20 minutes after tracer injection, half-body acquisition at 60 minutes and delayed pelvic scan at 90 minutes) between 2012 and August 2015. Subsequently following interim review of diagnostic performance, a streamlined protocol and appropriate-use criteria were introduced. Forty-nine examinations were carried out using the single-phase protocol between 2015 and 2017. Twenty-nine (69%) of the triple-phase studies were positive for recurrence compared to 38 (78%) of the single-phase studies. Only one patient who had a single-phase study would have benefited from a dynamic acquisition, they have required no further treatment or imaging and are currently under prostate-specific antigen (PSA) surveillance. Choline PET-CT remains a useful tool for the detection of prostate recurrence when used in combination with appropriate-use criteria. Removal of dynamic and delayed acquisition phases reduces study time without adversely affecting accuracy. Benefits include shorter imaging time which improves patient comfort, reduced cost, and improved scanner efficiency. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Reducing Delay in Diagnosis: Multistage Recommendation Tracking.
Wandtke, Ben; Gallagher, Sarah
2017-11-01
The purpose of this study was to determine whether a multistage tracking system could improve communication between health care providers, reducing the risk of delay in diagnosis related to inconsistent communication and tracking of radiology follow-up recommendations. Unconditional recommendations for imaging follow-up of all diagnostic imaging modalities excluding mammography (n = 589) were entered into a database and tracked through a multistage tracking system for 13 months. Tracking interventions were performed for patients for whom completion of recommended follow-up imaging could not be identified 1 month after the recommendation due date. Postintervention compliance with the follow-up recommendation required examination completion or clinical closure (i.e., biopsy, limited life expectancy or death, or subspecialist referral). Baseline radiology information system checks performed 1 month after the recommendation due date revealed timely completion of 43.1% of recommended imaging studies at our institution before intervention. Three separate tracking interventions were studied, showing effectiveness between 29.0% and 57.8%. The multistage tracking system increased the examination completion rate to 70.5% (a 52% increase) and reduced the rate of unknown follow-up compliance and the associated risk of delay in diagnosis to 13.9% (a 74% decrease). Examinations completed after tracking intervention generated revenue of 4.1 times greater than the labor cost. Performing sequential radiology recommendation tracking interventions can substantially reduce the rate of unknown follow-up compliance and add value to the health system. Unknown follow-up compliance is a risk factor for delay in diagnosis, a form of preventable medical error commonly identified in malpractice claims involving radiologists and office-based practitioners.
MULTIMODAL IMAGING IN VORTEX VEIN VARICES.
Veronese, Chiara; Staurenghi, Giovanni; Pellegrini, Marco; Maiolo, Chiara; Primavera, Laura; Morara, Mariachiara; Armstrong, Grayson W; Ciardella, Antonio P
2017-03-22
The aim of this study is to describe the clinical presentation of vortex vein varices with multimodal imaging. The authors carried out a retrospective case series of eight patients (7 female, 1 male) with an average age of 60.2 years (min 8, max 84, median 68.5) presenting with vortex vein varices. All patients were evaluated at the Sant'Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy and at Luigi Sacco Hospital, University of Milan, Milan, Italy. Patients underwent complete ophthalmologic examinations, including best corrected visual acuity, intraocular pressure, anterior segment, and fundus examination. Imaging studies, including fundus color photography, near-infrared reflectance imaging, fundus autofluorescence, fluorescein angiography, indocyanine green angiography, and spectral-domain enhanced depth imaging optical coherence tomography were also performed. Ultra-widefield fluorescein angiography and ultra-widefield indocyanine angiography using the Heidelberg Retina Angiograph and the Staurenghi 230 SLO Retina Lens were used to demonstrate the disappearance of all retinal lesions when pressure was applied to the globe. All eight cases initially presented to the emergency room. One patient presented secondary to trauma, two patients presented for suspected hemangioma, whereas the other five were referred to the authors' hospitals for suspected retinal lesions. On examination, retinal abnormalities were identified in all 8 patients, with 7 (87.5%) oculus dexter and 1 (12.5%) oculus sinister, and with 1 (12.5%) inferotemporally, 3 (37.5%) superonasally, 3 (37.5%) inferonasally, and 1 (12.5%) inferiorly. Fundus color photography showed an elevated lesion in seven patients and a nonelevated red lesion in one patient. In all patients, near-infrared reflectance imaging showed a hyporeflective lesion in the periphery of the retina. Fundus autofluorescence identified round hypofluorescent rings surrounding weakly hyperfluorescent lesions in all patients. On fluorescein angiography, all lesions were initially hyperfluorescent with a hypofluorescent ring, with the lesion becoming hyperfluorescent after injection of dye. Indocyanine green angiography demonstrated dilation of the vortex vein ampullae in all patients. Spectral-domain enhanced depth imaging optical coherence tomography demonstrated dilated choroidal vessels and a hyporeflective cavity without subretinal fluid in all patients. Ultra-widefield fluorescein angiography and ultra-widefield indocyanine angiography demonstrated disappearance of all retinal lesions when pressure was applied to the globe. Findings are consistent with the diagnosis of vortex vein varix in all eight patients, with six patients (75%) exhibiting a single varix and two patients (25%) exhibiting a double varix. The diagnosis of vortex vein varices can be confirmed through clinical examination through the use of digital pressure to the globe during ophthalmoscopic examination. Adjunctive multimodal imaging (fundus color photography, near-infrared reflectance imaging, fundus autofluorescence, fluorescein angiography, indocyanine angiography, and spectral-domain enhanced depth imaging optical coherence tomography) was useful in the diagnosis of vortex vein varices in the authors' clinical cases. However, in more challenging clinical cases, the authors' novel use of the ultra-widefield contact lens for application of ocular pressure with a resulting resolution of the varix proved to be a useful and easy diagnostic imaging method for confirming the presence of vortex vein varices.
Lara-Capi, Cynthia; Lingström, Peter; Lai, Gianfranco; Cocco, Fabio; Simark-Mattsson, Charlotte; Campus, Guglielmo
2017-01-01
Objectives: This article aimed to evaluate: (a) the agreement between a near-infrared light transillumination device and clinical and radiographic examinations in caries lesion detection and (b) the reliability of images captured by the transillumination device. Methods: Two calibrated examiners evaluated the caries status in premolars and molars on 52 randomly selected subjects by comparing the transillumination device with a clinical examination for the occlusal surfaces and by comparing the transillumination device with a radiographic examination (bitewing radiographs) for the approximal surfaces. Forty-eight trained dental hygienists evaluated and reevaluated 30 randomly selected images 1-month later. Results: A high concordance between transillumination method and clinical examination (kappa = 0.99) was detected for occlusal caries lesions, while for approximal surfaces, the transillumination device identified a higher number of lesions with respect to bitewing (kappa = 0.91). At the dentinal level, the two methods identified the same number of caries lesions (kappa = 1), whereas more approximal lesions were recorded using the transillumination device in the enamel (kappa = 0.24). The intraexaminer reliability was substantial/almost perfect in 59.4% of the participants. Conclusions: The transillumination method showed a high concordance compared with traditional methods (clinical examination and bitewing radiographs). Caries detection reliability using the transillumination device images showed a high intraexaminer agreement. Transillumination showed to be a reliable method and as effective as traditional methods in caries detection. PMID:28191797
Old high resolution satellite images for landscape archaeology: case studies from Turkey and Iraq
NASA Astrophysics Data System (ADS)
Scardozzi, Giuseppe
2008-10-01
The paper concerns the contribution for Landscape Archaeology from satellite images of 1960s and 1970s, very useful when old aerial photographs are scarce. Particularly, the study concerns the panchromatic photos taken by USA reconnaissance satellites from 1963 to 1972, declassified for civil use in 1995 and 2002, that in the last years are very used in the archaeological research; in fact, a lot of these images have an high geometric resolution, about between 2.74 and 1.83 m (Corona KH-4A and KH-4B), and some have a ground resolution about between 1.20 and 0.60 m (Gambit KH-7). These satellite images allow to examine very in detail ancient urban areas and territories that later are changed or partially destroyed; so, it is possible to detect and examine ancient structures, palaeo-environmental elements and archaeological traces of buried features now not visible. The paper presents some exemplificative cases study in Turkey and Iraq, in which the analysis of these images has made a fundamental contribution to the archaeological researches: particularly, for the reconstruction of the urban layout of the ancient city of Hierapolis of Phrygia and for the surveys in its territory, and for the study of the ancient topography of some archaeological sites of Iraq. In this second case, the research is gained in the context of the Iraq Virtual Museum Project; the comparison with recent high resolution satellite images (Ikonos-2, QuickBird-2, WorldView-1) also provide a fundamental tool for monitoring archaeological areas and for an evaluation of the situation after the first and the second Gulf War.
Wood, T J; Moore, C S; Stephens, A; Saunderson, J R; Beavis, A W
2015-09-01
Given the increasing use of computed tomography (CT) in the UK over the last 30 years, it is essential to ensure that all imaging protocols are optimised to keep radiation doses as low as reasonably practicable, consistent with the intended clinical task. However, the complexity of modern CT equipment can make this task difficult to achieve in practice. Recent results of local patient dose audits have shown discrepancies between two Philips CT scanners that use the DoseRight 2.0 automatic exposure control (AEC) system in the 'automatic' mode of operation. The use of this system can result in drifting dose and image quality performance over time as it is designed to evolve based on operator technique. The purpose of this study was to develop a practical technique for configuring examination protocols on four CT scanners that use the DoseRight 2.0 AEC system in the 'manual' mode of operation. This method used a uniform phantom to generate reference images which form the basis for how the AEC system calculates exposure factors for any given patient. The results of this study have demonstrated excellent agreement in the configuration of the CT scanners in terms of average patient dose and image quality when using this technique. This work highlights the importance of CT protocol harmonisation in a modern Radiology department to ensure both consistent image quality and radiation dose. Following this study, the average radiation dose for a range of CT examinations has been reduced without any negative impact on clinical image quality.
Aung, Winn; Jin, Zhao-Hui; Furukawa, Takako; Claron, Michael; Boturyn, Didier; Sogawa, Chizuru; Tsuji, Atsushi B; Wakizaka, Hidekatsu; Fukumura, Toshimitsu; Fujibayashi, Yasuhisa; Dumy, Pascal; Saga, Tsuneo
2013-09-01
The purpose of this study was to develop a clinically relevant orthotopic xenotransplantation model of pancreatic cancer and to perform a preclinical evaluation of a new positron emission tomography (PET) imaging probe, ⁶⁴Cu-labeled cyclam-RAFT-c(-RGDfK-)₄ peptide (⁶⁴Cu-RAFT-RGD), using this model. Varying degrees of αvβ₃ integrin expression in several human pancreatic cancer cell lines were examined by flow cytometry and Western blotting. The cell line BxPC-3, which is stably transfected with a red fluorescence protein (RFP), was used for surgical orthotopic implantation. Orthotopic xenograft was established in the pancreas of recipient nude mice. An in vivo probe biodistribution and receptor blocking study, preclinical PET imaging coregistered with contrast-enhanced computed tomography (CECT) comparing ⁶⁴Cu-RAFT-RGD and ¹⁸F-fluoro-2-deoxy-d-glucose (¹⁸F-FDG) accumulation in tumor, postimaging autoradiography, and histologic and immunohistochemical examinations were done. Biodistribution evaluation with a blocking study confirmed that efficient binding of probe to tumor is highly αvβ₃ integrin specific. ⁶⁴Cu-RAFT-RGD PET combined with CECT provided for precise and easy detection of cancer lesions. Autoradiography, histologic, and immunohistochemical examinations confirmed the accumulation of ⁶⁴Cu-RAFT-RGD in tumor versus nontumor tissues. In comparative PET studies, ⁶⁴Cu-RAFT-RGD accumulation provided better tumor contrast to background than ¹⁸F-FDG. Our results suggest that ⁶⁴Cu-RAFT-RGD PET imaging is potentially applicable for the diagnosis of αvβ₃ integrin-expressing pancreatic tumors.
Lam, Jacob; Wilkinson, James; Brassett, Cecilia; Brown, Jonathan
2018-05-01
Background and study aim Magnetic imaging technology is of proven benefit to trainees in colonoscopy, but few studies have examined its benefits in experienced hands. There is evidence that colonoscopy is more difficult in women. We set out to investigate (i) associations between the looping configurations in the proximal and distal colon and (ii) differences in the looping prevalence between the sexes. We have examined their significance in terms of segmental intubation times and position changes required for the completion of colonoscopy. Patients and methods We analyzed 103 consecutive synchronized luminal and magnetic image videos of diagnostic colonoscopies with normal anatomy undertaken by a single experienced operator. Results Deep transverse loops and sigmoid N-loops were more common in females. A deep transverse loop was more likely to be present if a sigmoid alpha-loop or N-loop had formed previously. Patients with sigmoid N-loops were turned more frequently from left lateral to supine before the sigmoid-descending junction was reached, but there was no statistical correlation between completion time and looping pattern. Conclusions This study has reexamined the prevalence of the common looping patterns encountered during colonoscopy and has identified differences between the sexes. This finding may offer an explanation as to why colonoscopy has been shown to be more difficult in females. Although a deep transverse loop following a resolved sigmoid alpha-loop was the most commonly encountered pattern, no statistical correlation between completion time and looping pattern could be shown. It is the first study to examine segmental completion times using a magnetic imager in expert hands.
Near-IR multi-modal imaging of natural occlusal lesions
NASA Astrophysics Data System (ADS)
Lee, Dustin; Fried, Daniel; Darling, Cynthia L.
2009-02-01
Reflectance and transillumination imaging show demineralization with high contrast in the near-IR. The objective of this study is to use lesion size and contrast acquired in reflectance and transillumination near-infrared imaging modes to estimate the severity of natural occlusal caries lesions. Previous studies have shown that near-infrared (NIR) light can be used to effectively image artificial carious lesions. However, its efficacy on natural lesions requires further exploration. Fifty extracted teeth with varying amounts of occlusal decay were examined using a NIR imaging system operating at 1310-nm. Image analysis software was used to calculate contrast values between sound and carious tooth structure. After imaging, teeth were histologically sampled at 1-mm intervals in order to determine lesion depth. Lesion contrast in transillumination mode significantly increased with lesion depth (p<0.001), while lesion contrast in reflectance mode did not increase. The lesion area demonstrated a significant increase with lesion severity in both imaging modes. These results suggest that lesion contrast and area can be used to estimate lesion severity in NIR images.
Institute for Molecular Medicine Research Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phelps, Michael E
2012-12-14
The objectives of the project are the development of new Positron Emission Tomography (PET) imaging instrumentation, chemistry technology platforms and new molecular imaging probes to examine the transformations from normal cellular and biological processes to those of disease in pre-clinical animal models. These technology platforms and imaging probes provide the means to: 1. Study the biology of disease using pre-clinical mouse models and cells. 2. Develop molecular imaging probes for imaging assays of proteins in pre-clinical models. 3. Develop imaging assays in pre-clinical models to provide to other scientists the means to guide and improve the processes for discovering newmore » drugs. 4. Develop imaging assays in pre-clinical models for others to use in judging the impact of drugs on the biology of disease.« less
Kay, Johnson C; Higgs, Jay B; Battafarano, Daniel F
2014-01-01
To analyze the utility of musculoskeletal ultrasound (MSUS) in a rheumatology department and characterize relevant clinical trends. Electronic medical records of all patients (n = 503) requiring MSUS in our department from January 2007 to December 2011 were reviewed. Rheumatologists performed MSUS using MyLab 25 or MyLab 70 systems. Clinical data were collected, including age, sex, symptoms, joint(s) examined, MSUS findings, procedures, further radiologic studies, and additional specialty consults. Results were tabulated from 717 total MSUS encounters and each was categorized as a completed encounter or an incomplete encounter. All magnetic resonance imaging (MRI) reports that followed MSUS were examined for concurrence. Cumulative numbers of MSUS examinations and MRIs were totaled. The Medicare global national average cost for MRIs and potential savings were calculated. A total of 789 joint sites were examined by MSUS. There were 84 US-guided procedures. Overall, 158 specialty consults were generated. After MSUS, 55 additional radiologic studies were ordered. There were 613 (85.5%) primary completed MSUS encounters and 104 cases (14.5%) requiring further imaging studies or an orthopedic consultation. There was an increased use of MSUS and a concurrent decreased use of MRI in our department over 4 consecutive years. We calculated the total potential savings from our rheumatology service to the Department of Defense as approximately $27,937.80 to $38,047.20 over 4 years. MSUS has a positive impact in a rheumatology practice. MSUS augments the clinical examination, influences diagnosis and management, decreases reliance on other imaging modalities, and reduces health care costs. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.
Venkatasubramanian, Ganesan; Puthumana, Dawn Thomas K.; Jayakumar, Peruvumba N.; Gangadhar, B. N.
2010-01-01
Background: Emotion processing abnormalities are considered among the core deficits in schizophrenia. Subjects at high risk (HR) for schizophrenia also show these deficits. Structural neuroimaging studies examining unaffected relatives at high risk for schizophrenia have demonstrated neuroanatomical abnormalities involving neo-cortical and sub-cortical brain regions related to emotion processing. The brain functional correlates of emotion processing in these HR subjects in the context of ecologically valid, real-life dynamic images using functional Magnetic Resonance Imaging (fMRI) has not been examined previously. Aim: To examine the neurohemodynamic abnormalities during emotion processing in unaffected subjects at high risk for schizophrenia in comparison with age-, sex-, handedness- and education-matched healthy controls, using fMRI. Materials and Methods: HR subjects for schizophrenia (n=17) and matched healthy controls (n=16) were examined. The emotion processing of fearful facial expression was examined using a culturally appropriate and valid tool for Indian subjects. The fMRI was performed in a 1.5-T scanner during an implicit emotion processing paradigm. The fMRI analyses were performed using the Statistical Parametric Mapping 2 (SPM2) software. Results: HR subjects had significantly reduced brain activations in left insula, left medial frontal gyrus, left inferior frontal gyrus, right cingulate gyrus, right precentral gyrus and right inferior parietal lobule. Hypothesis-driven region-of-interest analysis revealed hypoactivation of right amygdala in HR subjects. Conclusions: Study findings suggest that neurohemodynamic abnormalities involving limbic and frontal cortices could be potential indicators for increased vulnerability toward schizophrenia. The clinical utility of these novel findings in predicting the development of psychosis needs to be evaluated. PMID:21267363
The role of images in the development of Renaissance natural history.
Kusukawa, Sachiko
2011-01-01
This review surveys recent scholarship on the history of natural history with special attention to the role of images in the Renaissance. It discusses how classicism, collecting and printing were important catalysts for the Renaissance study of nature. Classicism provided inspiration of how to study and what kind of object to examine in nature, and several images from the period can be shown to reflect these classical values. The development of the passion for collecting and the rise of commerce in nature's commodities led to the circulation of a large number of exotic flora and fauna. Pictures enabled scholars to access unobtainable objects, build up knowledge of rare objects over time, and study them long after the live specimens had died away. Printing replicated pictures alongside texts and enabled scholars to share and accumulate knowledge. Images, alongside objects and text, were an important means of studying nature. Naturalists' images, in turn, became part of a larger visual culture in which nature was regarded as a beautiful and fascinating object of admiration.
Visual feature extraction from voxel-weighted averaging of stimulus images in 2 fMRI studies.
Hart, Corey B; Rose, William J
2013-11-01
Multiple studies have provided evidence for distributed object representation in the brain, with several recent experiments leveraging basis function estimates for partial image reconstruction from fMRI data. Using a novel combination of statistical decomposition, generalized linear models, and stimulus averaging on previously examined image sets and Bayesian regression of recorded fMRI activity during presentation of these data sets, we identify a subset of relevant voxels that appear to code for covarying object features. Using a technique we term "voxel-weighted averaging," we isolate image filters that these voxels appear to implement. The results, though very cursory, appear to have significant implications for hierarchical and deep-learning-type approaches toward the understanding of neural coding and representation.
Infrared imaging enhances retinal crystals in Bietti’s crystalline dystrophy
Brar, Vikram S; Benson, William H
2015-01-01
Infrared imaging dramatically increased the number of crystalline deposits visualized compared with clinical examination, standard color fundus photography, and red free imaging in patients with Bietti’s crystalline dystrophy. We believe that this imaging modality significantly improves the sensitivity with which these lesions are detected, facilitating earlier diagnosis and may potentially serve as a prognostic indicator when examined over time. PMID:25931805
NASA Astrophysics Data System (ADS)
Brook, A.; Cristofani, E.; Vandewal, M.; Matheis, C.; Jonuscheit, J.; Beigang, R.
2012-05-01
The present study proposes a fully integrated, semi-automatic and near real-time mode-operated image processing methodology developed for Frequency-Modulated Continuous-Wave (FMCW) THz images with the center frequencies around: 100 GHz and 300 GHz. The quality control of aeronautics composite multi-layered materials and structures using Non-Destructive Testing is the main focus of this work. Image processing is applied on the 3-D images to extract useful information. The data is processed by extracting areas of interest. The detected areas are subjected to image analysis for more particular investigation managed by a spatial model. Finally, the post-processing stage examines and evaluates the spatial accuracy of the extracted information.