Deep learning and non-negative matrix factorization in recognition of mammograms
NASA Astrophysics Data System (ADS)
Swiderski, Bartosz; Kurek, Jaroslaw; Osowski, Stanislaw; Kruk, Michal; Barhoumi, Walid
2017-02-01
This paper presents novel approach to the recognition of mammograms. The analyzed mammograms represent the normal and breast cancer (benign and malignant) cases. The solution applies the deep learning technique in image recognition. To obtain increased accuracy of classification the nonnegative matrix factorization and statistical self-similarity of images are applied. The images reconstructed by using these two approaches enrich the data base and thanks to this improve of quality measures of mammogram recognition (increase of accuracy, sensitivity and specificity). The results of numerical experiments performed on large DDSM data base containing more than 10000 mammograms have confirmed good accuracy of class recognition, exceeding the best results reported in the actual publications for this data base.
Comparison of Feature Selection Techniques in Machine Learning for Anatomical Brain MRI in Dementia.
Tohka, Jussi; Moradi, Elaheh; Huttunen, Heikki
2016-07-01
We present a comparative split-half resampling analysis of various data driven feature selection and classification methods for the whole brain voxel-based classification analysis of anatomical magnetic resonance images. We compared support vector machines (SVMs), with or without filter based feature selection, several embedded feature selection methods and stability selection. While comparisons of the accuracy of various classification methods have been reported previously, the variability of the out-of-training sample classification accuracy and the set of selected features due to independent training and test sets have not been previously addressed in a brain imaging context. We studied two classification problems: 1) Alzheimer's disease (AD) vs. normal control (NC) and 2) mild cognitive impairment (MCI) vs. NC classification. In AD vs. NC classification, the variability in the test accuracy due to the subject sample did not vary between different methods and exceeded the variability due to different classifiers. In MCI vs. NC classification, particularly with a large training set, embedded feature selection methods outperformed SVM-based ones with the difference in the test accuracy exceeding the test accuracy variability due to the subject sample. The filter and embedded methods produced divergent feature patterns for MCI vs. NC classification that suggests the utility of the embedded feature selection for this problem when linked with the good generalization performance. The stability of the feature sets was strongly correlated with the number of features selected, weakly correlated with the stability of classification accuracy, and uncorrelated with the average classification accuracy.
Bompastore, Nicholas J; Cisu, Theodore; Holoch, Peter
2018-04-30
To characterize available information about Peyronie disease online and evaluate its readability, quality, accuracy, and respective associations with HONcode certification and website category. The search term "Peyronie disease" was queried on 3 major search engines (Google, Bing, and Yahoo) and the first 50 search results on each search engine were assessed. All websites were categorized as institutional or reference, commercial, charitable, personal or patient support, or alternative medicine, and cross-referenced with the Health on the Net (HON) Foundation. Websites that met the inclusion criteria were analyzed for readability using 3 validated algorithms, for quality using the DISCERN instrument, and for accuracy by a fellowship-trained urologist. On average, online health information about treatment of Peyronie disease is written at or above the 11th grade level, exceeding the current reading guidelines of 6th-8th grade. The mean total DISCERN score for all website categories was 50.44 (standard deviation [SD] 11.94), the upper range of "fair" quality. The mean accuracy score of all online Peyronie treatment information was 2.76 (SD 1.23), corresponding to only 25%-50% accurate information. Both institutional or reference and HONcode-certified websites were of "good" quality (53.44, SD 11.64 and 60.86, SD 8.74, respectively). Institutional or reference websites were 50%-75% accurate (3.13, SD 1.20). Most of the online Peyronie disease treatment information is of mediocre quality and accuracy. The information from institutional or reference websites is of better quality and accuracy, and the information from HONcode-certified websites is of better quality. The mean readability of all websites exceeds the reading ability of most US adults by several grade levels. Copyright © 2018 Elsevier Inc. All rights reserved.
Evaluation of the Eureka Manta2 Water-Quality Multiprobe Sonde
Tillman, Evan F.
2017-11-08
Two Eureka Manta2 3.5 water-quality multiprobe sondes by Eureka Water Probes were tested at the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) against known standards over the sonde operating temperatures to verify the manufacturer’s stated accuracy specifications for pH, specific conductance (SC) at 25 degrees Celsius (°C), dissolved oxygen (DO), and turbidity. The Manta2 sondes were evaluated for compliance with the USGS National Field Manual for the Collection of Water-Quality Data (NFM) criteria for continuous water-quality monitors, and for compliance with the manufacturer’s technical specifications. The Manta2 was also evaluated for its compliance to Serial Digital Interface at 1200 baud (SDI-12) version 1.3.The Manta2 met the NFM recommendations and manufacturer’s accuracy specifications for DO and turbidity at all values tested. The Manta2 pH sensors met the NFM recommendations and manufacturer’s accuracy specification for nominal pH values of 10 and lower. One of the two sensors was out of compliance by 1.2 units for pH 11.16 at 15 °C and by 0.25 unit for pH 10.78 at 40 °C. The Manta2 sensors were within the NFM recommendations for SC, except at 100 microsiemens (μS/cm) at 40 °C, where the SC sensor exceeded the test standard value by as much as 25 percent. One of two sensors was within manufacturer’s accuracy specifications at 25 °C for all the tested SC values, while the other SC sensor was outside the manufacturer’s accuracy specifications at 100 μS/cm, exceeding the test standard value by 9 percent. One of two sensors was outside the manufacturer’s accuracy specifications at 10,000 μS/cm at 15°C, exceeding the test standard value by 3 percent. One Manta2 passed SDI-12 compliance testing with a NR Systems SDI-12 Verifier. One Manta2 was field tested for 6 weeks at USGS station 02492620, National Space Technology Laboratories (NSTL) Station, Mississippi, on the Pearl River and showed overall good agreement with a well-maintained Hydrolab Datasonde 5X site sonde for water temperature, pH, and DO. Differences in SC values between the Manta2 and the site sonde were most likely due to differences in the deployment depth of the sondes.
Dimitriadis, Alexis; Palmer, Antony L; Thomas, Russell A S; Nisbet, Andrew; Clark, Catharine H
2017-06-01
To adapt and validate an anthropomorphic head phantom for use in a cranial radiosurgery audit. Two bespoke inserts were produced for the phantom: one for providing the target and organ at risk for delineation and the other for performing dose measurements. The inserts were tested to assess their positional accuracy. A basic treatment plan dose verification with an ionization chamber was performed to establish a baseline accuracy for the phantom and beam model. The phantom and inserts were then used to perform dose verification measurements of a radiosurgery plan. The dose was measured with alanine pellets, EBT extended dose film and a plastic scintillation detector (PSD). Both inserts showed reproducible positioning (±0.5 mm) and good positional agreement between them (±0.6 mm). The basic treatment plan measurements showed agreement to the treatment planning system (TPS) within 0.5%. Repeated film measurements showed consistent gamma passing rates with good agreement to the TPS. For 2%-2 mm global gamma, the mean passing rate was 96.7% and the variation in passing rates did not exceed 2.1%. The alanine pellets and PSD showed good agreement with the TPS (-0.1% and 0.3% dose difference in the target) and good agreement with each other (within 1%). The adaptations to the phantom showed acceptable accuracies. The presence of alanine and PSD do not affect film measurements significantly, enabling simultaneous measurements by all three detectors. Advances in knowledge: A novel method for thorough end-to-end test of radiosurgery, with capability to incorporate all steps of the clinical pathway in a time-efficient and reproducible manner, suitable for a national audit.
NASA Astrophysics Data System (ADS)
Neyer, F.; Nocerino, E.; Gruen, A.
2018-05-01
Creating 3-dimensional (3D) models of underwater scenes has become a common approach for monitoring coral reef changes and its structural complexity. Also in underwater archeology, 3D models are often created using underwater optical imagery. In this paper, we focus on the aspect of detecting small changes in the coral reef using a multi-temporal photogrammetric modelling approach, which requires a high quality control network. We show that the quality of a good geodetic network limits the direct change detection, i.e., without any further registration process. As the photogrammetric accuracy is expected to exceed the geodetic network accuracy by at least one order of magnitude, we suggest to do a fine registration based on a number of signalized points. This work is part of the Moorea Island Digital Ecosystem Avatar (IDEA) project that has been initiated in 2013 by a group of international researchers (https://mooreaidea.ethz.ch/).
Chen, Yibin; Chen, Jiaxi; Chen, Xuan; Wang, Min; Wang, Wei
2015-01-01
A new method of uniform sampling is evaluated in this paper. The items and indexes were adopted to evaluate the rationality of the uniform sampling. The evaluation items included convenience of operation, uniformity of sampling site distribution, and accuracy and precision of measured results. The evaluation indexes included operational complexity, occupation rate of sampling site in a row and column, relative accuracy of pill weight, and relative deviation of pill weight. They were obtained from three kinds of drugs with different shape and size by four kinds of sampling methods. Gray correlation analysis was adopted to make the comprehensive evaluation by comparing it with the standard method. The experimental results showed that the convenience of uniform sampling method was 1 (100%), odds ratio of occupation rate in a row and column was infinity, relative accuracy was 99.50-99.89%, reproducibility RSD was 0.45-0.89%, and weighted incidence degree exceeded the standard method. Hence, the uniform sampling method was easy to operate, and the selected samples were distributed uniformly. The experimental results demonstrated that the uniform sampling method has good accuracy and reproducibility, which can be put into use in drugs analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robert V. Kolarik II
2002-10-23
A system for the online, non-contact measurement of wall thickness in steel seamless mechanical tubing has been developed and demonstrated at a tubing production line at the Timken Company in Canton, Ohio. The system utilizes laser-generation of ultrasound and laser-detection of time of flight with interferometry, laser-doppler velocimetry and pyrometry, all with fiber coupling. Accuracy (<1% error) and precision (1.5%) are at targeted levels. Cost and energy savings have exceeded estimates. The system has shown good reliability in measuring over 200,000 tubes in its first six months of deployment.
Correlation and registration of ERTS multispectral imagery. [by a digital processing technique
NASA Technical Reports Server (NTRS)
Bonrud, L. O.; Henrikson, P. J.
1974-01-01
Examples of automatic digital processing demonstrate the feasibility of registering one ERTS multispectral scanner (MSS) image with another obtained on a subsequent orbit, and automatic matching, correlation, and registration of MSS imagery with aerial photography (multisensor correlation) is demonstrated. Excellent correlation was obtained with patch sizes exceeding 16 pixels square. Qualities which lead to effective control point selection are distinctive features, good contrast, and constant feature characteristics. Results of the study indicate that more than 300 degrees of freedom are required to register two standard ERTS-1 MSS frames covering 100 by 100 nautical miles to an accuracy of 0.6 pixel mean radial displacement error. An automatic strip processing technique demonstrates 600 to 1200 degrees of freedom over a quater frame of ERTS imagery. Registration accuracies in the range of 0.3 pixel to 0.5 pixel mean radial error were confirmed by independent error analysis. Accuracies in the range of 0.5 pixel to 1.4 pixel mean radial error were demonstrated by semi-automatic registration over small geographic areas.
Thematic accuracy assessment of the 2011 National Land Cover Database (NLCD)
Wickham, James; Stehman, Stephen V.; Gass, Leila; Dewitz, Jon; Sorenson, Daniel G.; Granneman, Brian J.; Poss, Richard V.; Baer, Lori Anne
2017-01-01
Accuracy assessment is a standard protocol of National Land Cover Database (NLCD) mapping. Here we report agreement statistics between map and reference labels for NLCD 2011, which includes land cover for ca. 2001, ca. 2006, and ca. 2011. The two main objectives were assessment of agreement between map and reference labels for the three, single-date NLCD land cover products at Level II and Level I of the classification hierarchy, and agreement for 17 land cover change reporting themes based on Level I classes (e.g., forest loss; forest gain; forest, no change) for three change periods (2001–2006, 2006–2011, and 2001–2011). The single-date overall accuracies were 82%, 83%, and 83% at Level II and 88%, 89%, and 89% at Level I for 2011, 2006, and 2001, respectively. Many class-specific user's accuracies met or exceeded a previously established nominal accuracy benchmark of 85%. Overall accuracies for 2006 and 2001 land cover components of NLCD 2011 were approximately 4% higher (at Level II and Level I) than the overall accuracies for the same components of NLCD 2006. The high Level I overall, user's, and producer's accuracies for the single-date eras in NLCD 2011 did not translate into high class-specific user's and producer's accuracies for many of the 17 change reporting themes. User's accuracies were high for the no change reporting themes, commonly exceeding 85%, but were typically much lower for the reporting themes that represented change. Only forest loss, forest gain, and urban gain had user's accuracies that exceeded 70%. Lower user's accuracies for the other change reporting themes may be attributable to the difficulty in determining the context of grass (e.g., open urban, grassland, agriculture) and between the components of the forest-shrubland-grassland gradient at either the mapping phase, reference label assignment phase, or both. NLCD 2011 user's accuracies for forest loss, forest gain, and urban gain compare favorably with results from other land cover change accuracy assessments.
40 CFR 63.8 - Monitoring requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... in the relevant standard; or (B) The CMS fails a performance test audit (e.g., cylinder gas audit), relative accuracy audit, relative accuracy test audit, or linearity test audit; or (C) The COMS CD exceeds...) Data recording, calculations, and reporting; (v) Accuracy audit procedures, including sampling and...
40 CFR 51.164 - Stack height procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 51.164 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... source's stack height that exceeds good engineering practice or by any other dispersion technique, except... source based on a good engineering practice stack height that exceeds the height allowed by § 51.100(ii...
Modelling of PM10 concentration for industrialized area in Malaysia: A case study in Shah Alam
NASA Astrophysics Data System (ADS)
N, Norazian Mohamed; Abdullah, M. M. A.; Tan, Cheng-yau; Ramli, N. A.; Yahaya, A. S.; Fitri, N. F. M. Y.
In Malaysia, the predominant air pollutants are suspended particulate matter (SPM) and nitrogen dioxide (NO2). This research is on PM10 as they may trigger harm to human health as well as environment. Six distributions, namely Weibull, log-normal, gamma, Rayleigh, Gumbel and Frechet were chosen to model the PM10 observations at the chosen industrial area i.e. Shah Alam. One-year period hourly average data for 2006 and 2007 were used for this research. For parameters estimation, method of maximum likelihood estimation (MLE) was selected. Four performance indicators that are mean absolute error (MAE), root mean squared error (RMSE), coefficient of determination (R2) and prediction accuracy (PA), were applied to determine the goodness-of-fit criteria of the distributions. The best distribution that fits with the PM10 observations in Shah Alamwas found to be log-normal distribution. The probabilities of the exceedences concentration were calculated and the return period for the coming year was predicted from the cumulative density function (cdf) obtained from the best-fit distributions. For the 2006 data, Shah Alam was predicted to exceed 150 μg/m3 for 5.9 days in 2007 with a return period of one occurrence per 62 days. For 2007, the studied area does not exceed the MAAQG of 150 μg/m3
Aykut, Aktas; Bumin, Degirmenci; Omer, Yilmaz; Mustafa, Kayan; Meltem, Cetin; Orhan, Celik; Nisa, Unlu; Hikmet, Orhan; Hakan, Demirtas; Mert, Koroglu
2015-09-01
The aim was to compare coronary high-definition CT (HDCT) with standard-definition CT (SDCT) angiography as to radiation dose, image quality and accuracy. 28 patients with history of coronary artery disease scanned by HDCT (Discovery CT750 HD) and SDCT (Somatom Definition AS). The scan modes were both axial prospective ECG-triggered. The vessel diameters and vessel attenuation values of totally 280 measurements from 140 coronary arteries were analyzed by two experienced radiologists. All data was analyzed by intraclass correlation test. Image quality graded by motion and stair step artifacts (grade 1, poor, to grade 4, excellent), accuracy of vessel inner and outer diameters were compared between the two CT units using the independent samples t-test and Mann-Whitney U test. The intraclass correlation coefficient (ICC) of measured vessel attenuation values in SDCT between the two radiologists was exceedingly good. The ICC was higher in HDCT. The radiation dose of HDCT was higher than that of SDCT. The mean tube current was 180 (mA) in HDCT and 147(mA) in SDCT with the same tube voltage (kVp). There was no significant difference between image quality. HDCT has a higher radiation dose but has much more atenuation and the spatial resolution which improve measurement accuracy for imaging coronary arteries.
40 CFR 51.118 - Stack height provisions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... exceeds good engineering practice or by any other dispersion technique, except as provided in § 51.118(b... based on a good engineering practice stack height that exceeds the height allowed by § 51.100(ii) (1) or... actual stack height of any source. (b) The provisions of § 51.118(a) shall not apply to (1) stack heights...
Rapidly Mixing Gibbs Sampling for a Class of Factor Graphs Using Hierarchy Width.
De Sa, Christopher; Zhang, Ce; Olukotun, Kunle; Ré, Christopher
2015-12-01
Gibbs sampling on factor graphs is a widely used inference technique, which often produces good empirical results. Theoretical guarantees for its performance are weak: even for tree structured graphs, the mixing time of Gibbs may be exponential in the number of variables. To help understand the behavior of Gibbs sampling, we introduce a new (hyper)graph property, called hierarchy width . We show that under suitable conditions on the weights, bounded hierarchy width ensures polynomial mixing time. Our study of hierarchy width is in part motivated by a class of factor graph templates, hierarchical templates , which have bounded hierarchy width-regardless of the data used to instantiate them. We demonstrate a rich application from natural language processing in which Gibbs sampling provably mixes rapidly and achieves accuracy that exceeds human volunteers.
NASA Astrophysics Data System (ADS)
Saad, S. M.; Shakaff, A. Y. M.; Saad, A. R. M.; Yusof, A. M.; Andrew, A. M.; Zakaria, A.; Adom, A. H.
2017-03-01
There are various sources influencing indoor air quality (IAQ) which could emit dangerous gases such as carbon monoxide (CO), carbon dioxide (CO2), ozone (O3) and particulate matter. These gases are usually safe for us to breathe in if they are emitted in safe quantity but if the amount of these gases exceeded the safe level, they might be hazardous to human being especially children and people with asthmatic problem. Therefore, a smart indoor air quality monitoring system (IAQMS) is needed that able to tell the occupants about which sources that trigger the indoor air pollution. In this project, an IAQMS that able to classify sources influencing IAQ has been developed. This IAQMS applies a classification method based on Probabilistic Neural Network (PNN). It is used to classify the sources of indoor air pollution based on five conditions: ambient air, human activity, presence of chemical products, presence of food and beverage, and presence of fragrance. In order to get good and best classification accuracy, an analysis of several feature selection based on data pre-processing method is done to discriminate among the sources. The output from each data pre-processing method has been used as the input for the neural network. The result shows that PNN analysis with the data pre-processing method give good classification accuracy of 99.89% and able to classify the sources influencing IAQ high classification rate.
Thematic Accuracy Assessment of the 2011 National Land ...
Accuracy assessment is a standard protocol of National Land Cover Database (NLCD) mapping. Here we report agreement statistics between map and reference labels for NLCD 2011, which includes land cover for ca. 2001, ca. 2006, and ca. 2011. The two main objectives were assessment of agreement between map and reference labels for the three, single-date NLCD land cover products at Level II and Level I of the classification hierarchy, and agreement for 17 land cover change reporting themes based on Level I classes (e.g., forest loss; forest gain; forest, no change) for three change periods (2001–2006, 2006–2011, and 2001–2011). The single-date overall accuracies were 82%, 83%, and 83% at Level II and 88%, 89%, and 89% at Level I for 2011, 2006, and 2001, respectively. Many class-specific user's accuracies met or exceeded a previously established nominal accuracy benchmark of 85%. Overall accuracies for 2006 and 2001 land cover components of NLCD 2011 were approximately 4% higher (at Level II and Level I) than the overall accuracies for the same components of NLCD 2006. The high Level I overall, user's, and producer's accuracies for the single-date eras in NLCD 2011 did not translate into high class-specific user's and producer's accuracies for many of the 17 change reporting themes. User's accuracies were high for the no change reporting themes, commonly exceeding 85%, but were typically much lower for the reporting themes that represented change. Only forest l
Rapidly Mixing Gibbs Sampling for a Class of Factor Graphs Using Hierarchy Width
De Sa, Christopher; Zhang, Ce; Olukotun, Kunle; Ré, Christopher
2016-01-01
Gibbs sampling on factor graphs is a widely used inference technique, which often produces good empirical results. Theoretical guarantees for its performance are weak: even for tree structured graphs, the mixing time of Gibbs may be exponential in the number of variables. To help understand the behavior of Gibbs sampling, we introduce a new (hyper)graph property, called hierarchy width. We show that under suitable conditions on the weights, bounded hierarchy width ensures polynomial mixing time. Our study of hierarchy width is in part motivated by a class of factor graph templates, hierarchical templates, which have bounded hierarchy width—regardless of the data used to instantiate them. We demonstrate a rich application from natural language processing in which Gibbs sampling provably mixes rapidly and achieves accuracy that exceeds human volunteers. PMID:27279724
List, Susan M; Starks, Nykole; Baum, John; Greene, Carmine; Pardo, Scott; Parkes, Joan L; Schachner, Holly C; Cuddihy, Robert
2011-09-01
This study evaluated performance and product labeling of CONTOUR® USB, a new blood glucose monitoring system (BGMS) with integrated diabetes management software and a universal serial bus (USB) port, in the hands of untrained lay users and health care professionals (HCPs). Subjects and HCPs tested subject's finger stick capillary blood in parallel using CONTOUR USB meters; deep finger stick blood was tested on a Yellow Springs Instruments (YSI) glucose analyzer for reference. Duplicate results by both subjects and HCPs were obtained to assess system precision. System accuracy was assessed according to International Organization for Standardization (ISO) 15197:2003 guidelines [within ±15 mg/dl of mean YSI results (samples <75 mg/dl) and ±20% (samples ≥75 mg/dl)]. Clinical accuracy was determined by Parkes error grid analysis. Subject labeling comprehension was assessed by HCP ratings of subject proficiency. Key system features and ease-of-use were evaluated by subject questionnaires. All subjects who completed the study (N = 74) successfully performed blood glucose measurements, connected the meter to a laptop computer, and used key features of the system. The system was accurate; 98.6% (146/148) of subject results and 96.6% (143/148) of HCP results exceeded ISO 15197:2003 criteria. All subject and HCP results were clinically accurate (97.3%; zone A) or associated with benign errors (2.7%; zone B). The majority of subjects rated features of the BGMS as "very good" or "excellent." CONTOUR USB exceeded ISO 15197:2003 system performance criteria in the hands of untrained lay users. Subjects understood the product labeling, found the system easy to use, and successfully performed blood glucose testing. © 2011 Diabetes Technology Society.
Improving zero-training brain-computer interfaces by mixing model estimators
NASA Astrophysics Data System (ADS)
Verhoeven, T.; Hübner, D.; Tangermann, M.; Müller, K. R.; Dambre, J.; Kindermans, P. J.
2017-06-01
Objective. Brain-computer interfaces (BCI) based on event-related potentials (ERP) incorporate a decoder to classify recorded brain signals and subsequently select a control signal that drives a computer application. Standard supervised BCI decoders require a tedious calibration procedure prior to every session. Several unsupervised classification methods have been proposed that tune the decoder during actual use and as such omit this calibration. Each of these methods has its own strengths and weaknesses. Our aim is to improve overall accuracy of ERP-based BCIs without calibration. Approach. We consider two approaches for unsupervised classification of ERP signals. Learning from label proportions (LLP) was recently shown to be guaranteed to converge to a supervised decoder when enough data is available. In contrast, the formerly proposed expectation maximization (EM) based decoding for ERP-BCI does not have this guarantee. However, while this decoder has high variance due to random initialization of its parameters, it obtains a higher accuracy faster than LLP when the initialization is good. We introduce a method to optimally combine these two unsupervised decoding methods, letting one method’s strengths compensate for the weaknesses of the other and vice versa. The new method is compared to the aforementioned methods in a resimulation of an experiment with a visual speller. Main results. Analysis of the experimental results shows that the new method exceeds the performance of the previous unsupervised classification approaches in terms of ERP classification accuracy and symbol selection accuracy during the spelling experiment. Furthermore, the method shows less dependency on random initialization of model parameters and is consequently more reliable. Significance. Improving the accuracy and subsequent reliability of calibrationless BCIs makes these systems more appealing for frequent use.
40 CFR 63.8 - Monitoring requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... with conducting performance tests under § 63.7. Verification of operational status shall, at a minimum... in the relevant standard; or (B) The CMS fails a performance test audit (e.g., cylinder gas audit), relative accuracy audit, relative accuracy test audit, or linearity test audit; or (C) The COMS CD exceeds...
40 CFR 63.8 - Monitoring requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... with conducting performance tests under § 63.7. Verification of operational status shall, at a minimum... in the relevant standard; or (B) The CMS fails a performance test audit (e.g., cylinder gas audit), relative accuracy audit, relative accuracy test audit, or linearity test audit; or (C) The COMS CD exceeds...
The accuracy of selected land use and land cover maps at scales of 1:250,000 and 1:100,000
Fitzpatrick-Lins, Katherine
1980-01-01
Land use and land cover maps produced by the U.S. Geological Survey are found to meet or exceed the established standard of accuracy. When analyzed using a point sampling technique and binomial probability theory, several maps, illustrative of those produced for different parts of the country, were found to meet or exceed accuracies of 85 percent. Those maps tested were Tampa, Fla., Portland, Me., Charleston, W. Va., and Greeley, Colo., published at a scale of 1:250,000, and Atlanta, Ga., and Seattle and Tacoma, Wash., published at a scale of 1:100,000. For each map, the values were determined by calculating the ratio of the total number of points correctly interpreted to the total number of points sampled. Six of the seven maps tested have accuracies of 85 percent or better at the 95-percent lower confidence limit. When the sample data for predominant categories (those sampled with a significant number of points) were grouped together for all maps, accuracies of those predominant categories met the 85-percent accuracy criterion, with one exception. One category, Residential, had less than 85-percent accuracy at the 95-percent lower confidence limit. Nearly all residential land sampled was mapped correctly, but some areas of other land uses were mapped incorrectly as Residential.
Crystal growth and piezoelectric properties of Ca3Ta(Ga0.9Sc0.1)3Si2O14 bulk single crystal
NASA Astrophysics Data System (ADS)
Igarashi, Yu; Yokota, Yuui; Ohashi, Yuji; Inoue, Kenji; Yamaji, Akihiro; Shoji, Yasuhiro; Kamada, Kei; Kurosawa, Shunsuke; Yoshikawa, Akira
2018-03-01
Ca3Ta(Ga0.9Sc0.1)3Si2O14 langasite-type single crystal with a diameter of 1 in. was grown by Czochralski (Cz) method. Obtained crystal had good crystallinity and its lattice constants exceeded those of Ca3TaGa3Si2O14 (CTGS) according to the X-ray analysis. A crack-free specimen cut from the grown crystal was used for the measurements of dielectric constant ε11T/ε0, electromechanical coupling factor k12, and piezoelectric constant d11. The accuracies of these measurements were better than those for the crystal grown by micro-pulling-down (μ-PD) method. Substitution of Ga with Sc resulted modification of these constants in the directions opposite to those observed after partial substitution of Ga (of CTGS) with Al. This suggests that increase of |d14| was most probably associated with enlargement of average size of the Ga sites. The crystal reported here had greater dimensions as compared to analogous crystals grown by the μ-PD method. As a result, accuracy of determination of acoustic constants of this material may be improved.
21 CFR 172.878 - White mineral oil.
Code of Federal Regulations, 2013 CFR
2013-04-01
... yeast contamination during fermentation In an amount not to exceed good manufacturing practice. 4. As a..., and lubricant in the manufacture of yeast Not to exceed 0.15 percent of yeast. 13. As an antidusting...
21 CFR 172.878 - White mineral oil.
Code of Federal Regulations, 2012 CFR
2012-04-01
... yeast contamination during fermentation In an amount not to exceed good manufacturing practice. 4. As a..., and lubricant in the manufacture of yeast Not to exceed 0.15 percent of yeast. 13. As an antidusting...
21 CFR 172.878 - White mineral oil.
Code of Federal Regulations, 2011 CFR
2011-04-01
... yeast contamination during fermentation In an amount not to exceed good manufacturing practice. 4. As a..., and lubricant in the manufacture of yeast Not to exceed 0.15 percent of yeast. 13. As an antidusting...
21 CFR 184.1452 - Manganese gluconate.
Code of Federal Regulations, 2014 CFR
2014-04-01
... used in food with no limitation other than current good manufacturing practice. The affirmation of this... following current good manufacturing practice conditions of use: (1) The ingredient is used as a nutrient... levels not to exceed current good manufacturing practice: baked goods as defined in § 170.3(n)(1) of this...
Research on laser direct metal deposition
NASA Astrophysics Data System (ADS)
Zhang, Yongzhong; Shi, Likai
2003-03-01
Laser direct deposition of metallic parts is a new manufacturing technology, which combines with computer-aided design, laser cladding and rapid prototyping. Fully dense metallic parts can be directly obtained through melting the coaxially fed powders with a high-power laser in a layer-by-layer manner. The process characteristics, system composition as well as some research and advancement on laser direct deposition are presented here. The microstructure and properties observation of laser direct formed 663 copper alloy, 316L stainless steel and Rene'95 nickel super alloy samples indicate that, the as-deposited microstructure is similar to rapidly solidified materials, with homogenous composition and free of defects. Under certain conditions, directionally solidified microstructure can be obtained. The as-formed mechanical properties are equal to or exceed those for casting and wrought annealed materials. At the same time, some sample parts with complicate shape are presented for technology demonstration. The formed parts show good surface quality and dimensional accuracy.
NASA Technical Reports Server (NTRS)
Jenkins, Luther N.; Yao, Chung-Sheng; Bartram, Scott M.; Harris, Jerome; Allan, Brian; Wong, Oliver; Mace, W. Derry
2009-01-01
A Large Field-of-View Particle Image Velocimetry (LFPIV) system has been developed for rotor wake diagnostics in the 14-by 22-Foot Subsonic Tunnel. The system has been used to measure three components of velocity in a plane as large as 1.524 meters by 0.914 meters in both forward flight and hover tests. Overall, the system performance has exceeded design expectations in terms of accuracy and efficiency. Measurements synchronized with the rotor position during forward flight and hover tests have shown that the system is able to capture the complex interaction of the body and rotor wakes as well as basic details of the blade tip vortex at several wake ages. Measurements obtained with traditional techniques such as multi-hole pressure probes, Laser Doppler Velocimetry (LDV), and 2D Particle Image Velocimetry (PIV) show good agreement with LFPIV measurements.
ERIC Educational Resources Information Center
Cohen, Ira L.; Liu, Xudong; Hudson, Melissa; Gillis, Jennifer; Cavalari, Rachel N. S.; Romanczyk, Raymond G.; Karmel, Bernard Z.; Gardner, Judith M.
2016-01-01
In order to improve discrimination accuracy between Autism Spectrum Disorder (ASD) and similar neurodevelopmental disorders, a data mining procedure, Classification and Regression Trees (CART), was used on a large multi-site sample of PDD Behavior Inventory (PDDBI) forms on children with and without ASD. Discrimination accuracy exceeded 80%,…
21 CFR 184.1101 - Diacetyl tartaric acid esters of mono- and diglycerides.
Code of Federal Regulations, 2010 CFR
2010-04-01
... used in food with no limitation other than current good manufacturing practice. The affirmation of this... following current good manufacturing practice conditions of use: (1) The ingredient is used in food as an... levels not to exceed current good manufacturing practice: baked goods and baking mixes as defined in...
21 CFR 184.1101 - Diacetyl tartaric acid esters of mono- and diglycerides.
Code of Federal Regulations, 2011 CFR
2011-04-01
... used in food with no limitation other than current good manufacturing practice. The affirmation of this... following current good manufacturing practice conditions of use: (1) The ingredient is used in food as an... levels not to exceed current good manufacturing practice: baked goods and baking mixes as defined in...
A comprehensive evaluation of strip performance in multiple blood glucose monitoring systems.
Katz, Laurence B; Macleod, Kirsty; Grady, Mike; Cameron, Hilary; Pfützner, Andreas; Setford, Steven
2015-05-01
Accurate self-monitoring of blood glucose is a key component of effective self-management of glycemic control. Accurate self-monitoring of blood glucose results are required for optimal insulin dosing and detection of hypoglycemia. However, blood glucose monitoring systems may be susceptible to error from test strip, user, environmental and pharmacological factors. This report evaluated 5 blood glucose monitoring systems that each use Verio glucose test strips for precision, effect of hematocrit and interferences in laboratory testing, and lay user and system accuracy in clinical testing according to the guidelines in ISO15197:2013(E). Performance of OneTouch(®) VerioVue™ met or exceeded standards described in ISO15197:2013 for precision, hematocrit performance and interference testing in a laboratory setting. Performance of OneTouch(®) Verio IQ™, OneTouch(®) Verio Pro™, OneTouch(®) Verio™, OneTouch(®) VerioVue™ and Omni Pod each met or exceeded accuracy standards for user performance and system accuracy in a clinical setting set forth in ISO15197:2013(E).
Beaulieu, Jean; Doerksen, Trevor K; MacKay, John; Rainville, André; Bousquet, Jean
2014-12-02
Genomic selection (GS) may improve selection response over conventional pedigree-based selection if markers capture more detailed information than pedigrees in recently domesticated tree species and/or make it more cost effective. Genomic prediction accuracies using 1748 trees and 6932 SNPs representative of as many distinct gene loci were determined for growth and wood traits in white spruce, within and between environments and breeding groups (BG), each with an effective size of Ne ≈ 20. Marker subsets were also tested. Model fits and/or cross-validation (CV) prediction accuracies for ridge regression (RR) and the least absolute shrinkage and selection operator models approached those of pedigree-based models. With strong relatedness between CV sets, prediction accuracies for RR within environment and BG were high for wood (r = 0.71-0.79) and moderately high for growth (r = 0.52-0.69) traits, in line with trends in heritabilities. For both classes of traits, these accuracies achieved between 83% and 92% of those obtained with phenotypes and pedigree information. Prediction into untested environments remained moderately high for wood (r ≥ 0.61) but dropped significantly for growth (r ≥ 0.24) traits, emphasizing the need to phenotype in all test environments and model genotype-by-environment interactions for growth traits. Removing relatedness between CV sets sharply decreased prediction accuracies for all traits and subpopulations, falling near zero between BGs with no known shared ancestry. For marker subsets, similar patterns were observed but with lower prediction accuracies. Given the need for high relatedness between CV sets to obtain good prediction accuracies, we recommend to build GS models for prediction within the same breeding population only. Breeding groups could be merged to build genomic prediction models as long as the total effective population size does not exceed 50 individuals in order to obtain high prediction accuracy such as that obtained in the present study. A number of markers limited to a few hundred would not negatively impact prediction accuracies, but these could decrease more rapidly over generations. The most promising short-term approach for genomic selection would likely be the selection of superior individuals within large full-sib families vegetatively propagated to implement multiclonal forestry.
Sullivan, Edith V.; Brumback, Ty; Tapert, Susan F.; Fama, Rosemary; Prouty, Devin; Brown, Sandra A.; Cummins, Kevin; Thompson, Wesley K.; Colrain, Ian M.; Baker, Fiona C.; De Bellis, Michael D.; Hooper, Stephen R.; Clark, Duncan B.; Chung, Tammy; Nagel, Bonnie J.; Nichols, B. Nolan; Rohlfing, Torsten; Chu, Weiwei; Pohl, Kilian M.; Pfefferbaum, Adolf
2015-01-01
Objective To investigate development of cognitive and motor functions in healthy adolescents and to explore whether hazardous drinking affects the normal developmental course of those functions. Method Participants were 831 adolescents recruited across five United States sites of the National Consortium on Alcohol and NeuroDevelopment in Adolescence (NCANDA): 692 met criteria for no/low alcohol exposure, and 139 exceeded drinking thresholds. Cross-sectional, baseline data were collected with computerized and traditional neuropsychological tests assessing eight functional domains expressed as composite scores. General additive modeling evaluated factors potentially modulating performance (age, sex, ethnicity, socioeconomic status, and pubertal developmental stage). Results Older no/low-drinking participants achieved better scores than younger ones on five Accuracy composites (General Ability, Abstraction, Attention, Emotion, and Balance). Speeded responses for Attention, Motor Speed, and General Ability were sensitive to age and pubertal development. The exceeds-threshold group (accounting for age, sex, and other demographic factors) performed significantly below the no/low-drinking group on Balance accuracy and on General Ability, Attention, Episodic Memory, Emotion, and Motor speed scores and showed evidence for faster speed at the expense of accuracy. Delay Discounting performance was consistent with poor impulse control in the younger no/low drinkers and in exceeds-threshold drinkers regardless of age. Conclusions Higher achievement with older age and pubertal stage in General Ability, Abstraction, Attention, Emotion, and Balance suggests continued functional development through adolescence, possibly supported by concurrently maturing frontal, limbic, and cerebellar brain systems. Whether low scores by the exceeds-threshold group resulted from drinking or from other pre-existing factors requires longitudinal study. PMID:26752122
Sullivan, Edith V; Brumback, Ty; Tapert, Susan F; Fama, Rosemary; Prouty, Devin; Brown, Sandra A; Cummins, Kevin; Thompson, Wesley K; Colrain, Ian M; Baker, Fiona C; De Bellis, Michael D; Hooper, Stephen R; Clark, Duncan B; Chung, Tammy; Nagel, Bonnie J; Nichols, B Nolan; Rohlfing, Torsten; Chu, Weiwei; Pohl, Kilian M; Pfefferbaum, Adolf
2016-05-01
To investigate development of cognitive and motor functions in healthy adolescents and to explore whether hazardous drinking affects the normal developmental course of those functions. Participants were 831 adolescents recruited across 5 United States sites of the National Consortium on Alcohol and NeuroDevelopment in Adolescence 692 met criteria for no/low alcohol exposure, and 139 exceeded drinking thresholds. Cross-sectional, baseline data were collected with computerized and traditional neuropsychological tests assessing 8 functional domains expressed as composite scores. General additive modeling evaluated factors potentially modulating performance (age, sex, ethnicity, socioeconomic status, and pubertal developmental stage). Older no/low-drinking participants achieved better scores than younger ones on 5 accuracy composites (general ability, abstraction, attention, emotion, and balance). Speeded responses for attention, motor speed, and general ability were sensitive to age and pubertal development. The exceeds-threshold group (accounting for age, sex, and other demographic factors) performed significantly below the no/low-drinking group on balance accuracy and on general ability, attention, episodic memory, emotion, and motor speed scores and showed evidence for faster speed at the expense of accuracy. Delay Discounting performance was consistent with poor impulse control in the younger no/low drinkers and in exceeds-threshold drinkers regardless of age. Higher achievement with older age and pubertal stage in general ability, abstraction, attention, emotion, and balance suggests continued functional development through adolescence, possibly supported by concurrently maturing frontal, limbic, and cerebellar brain systems. Determination of whether low scores by the exceeds-threshold group resulted from drinking or from other preexisting factors requires longitudinal study. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
21 CFR 184.1452 - Manganese gluconate.
Code of Federal Regulations, 2012 CFR
2012-04-01
....1(b)(1), the ingredient is used in food with no limitation other than current good manufacturing... ingredient is based upon the following current good manufacturing practice conditions of use: (1) The... is used in the following foods at levels not to exceed current good manufacturing practice: baked...
21 CFR 184.1452 - Manganese gluconate.
Code of Federal Regulations, 2013 CFR
2013-04-01
....1(b)(1), the ingredient is used in food with no limitation other than current good manufacturing... ingredient is based upon the following current good manufacturing practice conditions of use: (1) The... is used in the following foods at levels not to exceed current good manufacturing practice: baked...
21 CFR 184.1452 - Manganese gluconate.
Code of Federal Regulations, 2011 CFR
2011-04-01
....1(b)(1), the ingredient is used in food with no limitation other than current good manufacturing... ingredient is based upon the following current good manufacturing practice conditions of use: (1) The... is used in the following foods at levels not to exceed current good manufacturing practice: baked...
21 CFR 184.1452 - Manganese gluconate.
Code of Federal Regulations, 2010 CFR
2010-04-01
....1(b)(1), the ingredient is used in food with no limitation other than current good manufacturing... ingredient is based upon the following current good manufacturing practice conditions of use: (1) The... is used in the following foods at levels not to exceed current good manufacturing practice: baked...
Reproducible segmentation of white matter hyperintensities using a new statistical definition.
Damangir, Soheil; Westman, Eric; Simmons, Andrew; Vrenken, Hugo; Wahlund, Lars-Olof; Spulber, Gabriela
2017-06-01
We present a method based on a proposed statistical definition of white matter hyperintensities (WMH), which can work with any combination of conventional magnetic resonance (MR) sequences without depending on manually delineated samples. T1-weighted, T2-weighted, FLAIR, and PD sequences acquired at 1.5 Tesla from 119 subjects from the Kings Health Partners-Dementia Case Register (healthy controls, mild cognitive impairment, Alzheimer's disease) were used. The segmentation was performed using a proposed definition for WMH based on the one-tailed Kolmogorov-Smirnov test. The presented method was verified, given all possible combinations of input sequences, against manual segmentations and a high similarity (Dice 0.85-0.91) was observed. Comparing segmentations with different input sequences to one another also yielded a high similarity (Dice 0.83-0.94) that exceeded intra-rater similarity (Dice 0.75-0.91). We compared the results with those of other available methods and showed that the segmentation based on the proposed definition has better accuracy and reproducibility in the test dataset used. Overall, the presented definition is shown to produce accurate results with higher reproducibility than manual delineation. This approach can be an alternative to other manual or automatic methods not only because of its accuracy, but also due to its good reproducibility.
A high performance sensor for triaxial cutting force measurement in turning.
Zhao, You; Zhao, Yulong; Liang, Songbo; Zhou, Guanwu
2015-04-03
This paper presents a high performance triaxial cutting force sensor with excellent accuracy, favorable natural frequency and acceptable cross-interference for high speed turning process. Octagonal ring is selected as sensitive element of the designed sensor, which is drawn inspiration from ring theory. A novel structure of two mutual-perpendicular octagonal rings is proposed and three Wheatstone full bridge circuits are specially organized in order to obtain triaxial cutting force components and restrain cross-interference. Firstly, the newly developed sensor is tested in static calibration; test results indicate that the sensor possesses outstanding accuracy in the range of 0.38%-0.83%. Secondly, impacting modal tests are conducted to identify the natural frequencies of the sensor in triaxial directions (i.e., 1147 Hz, 1122 Hz and 2035 Hz), which implies that the devised sensor can be used for cutting force measurement in a high speed lathe when the spindle speed does not exceed 17,205 rev/min in continuous cutting condition. Finally, an application of the sensor in turning process is operated to show its performance for real-time cutting force measurement; the measured cutting forces demonstrate a good accordance with the variation of cutting parameters. Thus, the developed sensor possesses perfect properties and it gains great potential for real-time cutting force measurement in turning.
A High Performance Sensor for Triaxial Cutting Force Measurement in Turning
Zhao, You; Zhao, Yulong; Liang, Songbo; Zhou, Guanwu
2015-01-01
This paper presents a high performance triaxial cutting force sensor with excellent accuracy, favorable natural frequency and acceptable cross-interference for high speed turning process. Octagonal ring is selected as sensitive element of the designed sensor, which is drawn inspiration from ring theory. A novel structure of two mutual-perpendicular octagonal rings is proposed and three Wheatstone full bridge circuits are specially organized in order to obtain triaxial cutting force components and restrain cross-interference. Firstly, the newly developed sensor is tested in static calibration; test results indicate that the sensor possesses outstanding accuracy in the range of 0.38%–0.83%. Secondly, impacting modal tests are conducted to identify the natural frequencies of the sensor in triaxial directions (i.e., 1147 Hz, 1122 Hz and 2035 Hz), which implies that the devised sensor can be used for cutting force measurement in a high speed lathe when the spindle speed does not exceed 17,205 rev/min in continuous cutting condition. Finally, an application of the sensor in turning process is operated to show its performance for real-time cutting force measurement; the measured cutting forces demonstrate a good accordance with the variation of cutting parameters. Thus, the developed sensor possesses perfect properties and it gains great potential for real-time cutting force measurement in turning. PMID:25855035
NASA Astrophysics Data System (ADS)
Wilschut, Liesbeth I.; Heesterbeek, Johan A. P.; Begon, Mike; de Jong, Steven M.; Ageyev, Vladimir; Laudisoit, Anne; Addink, Elisabeth A.
2018-02-01
In Kazakhstan, plague outbreaks occur when its main host, the great gerbil, exceeds an abundance threshold. These live in family groups in burrows, which can be mapped using remote sensing. Occupancy (percentage of burrows occupied) is a good proxy for abundance and hence the possibility of an outbreak. Here we use time series of satellite images to estimate occupancy remotely. In April and September 2013, 872 burrows were identified in the field as either occupied or empty. For satellite images acquired between April and August, 'burrow objects' were identified and matched to the field burrows. The burrow objects were represented by 25 different polygon types, then classified (using a majority vote from 10 Random Forests) as occupied or empty, using Normalized Difference Vegetation Indices (NDVI) calculated for all images. Throughout the season NDVI values were higher for empty than for occupied burrows. Occupancy status of individual burrows that were continuously occupied or empty, was classified with producer's and user's accuracy values of 63 and 64% for the optimum polygon. Occupancy level was predicted very well and differed 2% from the observed occupancy. This establishes firmly the principle that occupancy can be estimated using satellite images with the potential to predict plague outbreaks over extensive areas with much greater ease and accuracy than previously.
Yan, Yiming; Tan, Zhichao; Su, Nan; Zhao, Chunhui
2017-08-24
In this paper, a building extraction method is proposed based on a stacked sparse autoencoder with an optimized structure and training samples. Building extraction plays an important role in urban construction and planning. However, some negative effects will reduce the accuracy of extraction, such as exceeding resolution, bad correction and terrain influence. Data collected by multiple sensors, as light detection and ranging (LIDAR), optical sensor etc., are used to improve the extraction. Using digital surface model (DSM) obtained from LIDAR data and optical images, traditional method can improve the extraction effect to a certain extent, but there are some defects in feature extraction. Since stacked sparse autoencoder (SSAE) neural network can learn the essential characteristics of the data in depth, SSAE was employed to extract buildings from the combined DSM data and optical image. A better setting strategy of SSAE network structure is given, and an idea of setting the number and proportion of training samples for better training of SSAE was presented. The optical data and DSM were combined as input of the optimized SSAE, and after training by an optimized samples, the appropriate network structure can extract buildings with great accuracy and has good robustness.
El-Maghrabey, Mahmoud H; Kishikawa, Naoya; Ohyama, Kaname; Kuroda, Naotaka
2014-11-01
A validated, simple and sensitive HPLC method was developed for the simultaneous determination of lipoperoxidation relevant reactive aldehydes: glyoxal (GO), acrolein (ACR), malondialdehyde (MDA), and 4-hydroxy-2-nonenal (HNE) in human serum. The studied aldehydes were reacted with 2,2'-furil to form fluorescent difurylimidazole derivatives that were separated on a C18 column using gradient elution and fluorescence detection at excitation and emission wavelengths of 250 and 355nm, respectively. The method showed good linearity over the concentration ranges of 0.100-5.00, 0.200-10.0, 0.200-40.0, and 0.400-10.0nmol/mL for GO, ACR, HNE, and MDA, respectively, with detection limits ranging from 0.030 to 0.11nmol/mL. The percentage RSD of intraday and interday precision did not exceed 5.0 and 6.2%, respectively, and the accuracy (%found) ranged from 95.5 to 103%. The proposed method was applied for monitoring the four aldehydes in sera of healthy, diabetic, and rheumatic human subjects with simple pretreatment steps and without interference from endogenous components. By virtue of its high sensitivity and accuracy, our method enabled detection of differences between analytes concentrations in sera of human subjects under different clinical conditions. Copyright © 2014 Elsevier Inc. All rights reserved.
7 CFR 275.23 - Determination of State agency program performance.
Code of Federal Regulations, 2012 CFR
2012-01-01
... judicial review only if a liability amount is established for that fiscal year. Procedures for good cause... amount. However, State agencies may address matters related to good cause in an immediately prior fiscal.... (f) Good cause. When a State agency with otherwise effective administration exceeds the tolerance...
7 CFR 275.23 - Determination of State agency program performance.
Code of Federal Regulations, 2014 CFR
2014-01-01
... judicial review only if a liability amount is established for that fiscal year. Procedures for good cause... amount. However, State agencies may address matters related to good cause in an immediately prior fiscal.... (f) Good cause. When a State agency with otherwise effective administration exceeds the tolerance...
7 CFR 275.23 - Determination of State agency program performance.
Code of Federal Regulations, 2013 CFR
2013-01-01
... judicial review only if a liability amount is established for that fiscal year. Procedures for good cause... amount. However, State agencies may address matters related to good cause in an immediately prior fiscal.... (f) Good cause. When a State agency with otherwise effective administration exceeds the tolerance...
Code of Federal Regulations, 2014 CFR
2014-04-01
... section, a good that does not undergo a change in tariff classification pursuant to General Note 32(n), HTSUS, is an originating good if: (1) The value of all non-originating materials used in the production of the good that do not undergo the applicable change in tariff classification does not exceed 10...
Code of Federal Regulations, 2014 CFR
2014-04-01
... this section, a good that does not undergo a change in tariff classification pursuant to General Note 34, HTSUS, is an originating good if: (1) The value of all non-originating materials used in the production of the good that do not undergo the applicable change in tariff classification does not exceed 10...
Code of Federal Regulations, 2014 CFR
2014-04-01
... section, a good that does not undergo a change in tariff classification pursuant to General Note 35, HTSUS, is an originating good if: (1) The value of all non-originating materials used in the production of the good that do not undergo the applicable change in tariff classification does not exceed 10 percent...
Code of Federal Regulations, 2014 CFR
2014-04-01
... section, a good that does not undergo a change in tariff classification pursuant to General Note 33, HTSUS, is an originating good if: (1) The value of all non-originating materials used in the production of the good that do not undergo the applicable change in tariff classification does not exceed 10 percent...
21 CFR 184.1449 - Manganese citrate.
Code of Federal Regulations, 2014 CFR
2014-04-01
... § 184.1(b)(1), the ingredient is used in food with no limitation other than current good manufacturing... ingredient is based upon the following current good manufacturing practice conditions of use: (1) The... is used in the following foods at levels not to exceed current good manufacturing practice: baked...
Code of Federal Regulations, 2012 CFR
2012-04-01
... section, a good that does not undergo a change in tariff classification pursuant to General Note 33, HTSUS, is an originating good if: (1) The value of all non-originating materials used in the production of the good that do not undergo the applicable change in tariff classification does not exceed 10 percent...
Code of Federal Regulations, 2013 CFR
2013-04-01
... section, a good that does not undergo a change in tariff classification pursuant to General Note 32(n), HTSUS, is an originating good if: (1) The value of all non-originating materials used in the production of the good that do not undergo the applicable change in tariff classification does not exceed 10...
Code of Federal Regulations, 2012 CFR
2012-04-01
... section, a good that does not undergo a change in tariff classification pursuant to General Note 32(n), HTSUS, is an originating good if: (1) The value of all non-originating materials used in the production of the good that do not undergo the applicable change in tariff classification does not exceed 10...
Code of Federal Regulations, 2013 CFR
2013-04-01
... section, a good that does not undergo a change in tariff classification pursuant to General Note 33, HTSUS, is an originating good if: (1) The value of all non-originating materials used in the production of the good that do not undergo the applicable change in tariff classification does not exceed 10 percent...
Code of Federal Regulations, 2013 CFR
2013-04-01
... this section, a good that does not undergo a change in tariff classification pursuant to General Note 34, HTSUS, is an originating good if: (1) The value of all non-originating materials used in the production of the good that do not undergo the applicable change in tariff classification does not exceed 10...
Yu, Xiao; Ding, Enjie; Chen, Chunxu; Liu, Xiaoming; Li, Li
2015-01-01
Because roller element bearings (REBs) failures cause unexpected machinery breakdowns, their fault diagnosis has attracted considerable research attention. Established fault feature extraction methods focus on statistical characteristics of the vibration signal, which is an approach that loses sight of the continuous waveform features. Considering this weakness, this article proposes a novel feature extraction method for frequency bands, named Window Marginal Spectrum Clustering (WMSC) to select salient features from the marginal spectrum of vibration signals by Hilbert–Huang Transform (HHT). In WMSC, a sliding window is used to divide an entire HHT marginal spectrum (HMS) into window spectrums, following which Rand Index (RI) criterion of clustering method is used to evaluate each window. The windows returning higher RI values are selected to construct characteristic frequency bands (CFBs). Next, a hybrid REBs fault diagnosis is constructed, termed by its elements, HHT-WMSC-SVM (support vector machines). The effectiveness of HHT-WMSC-SVM is validated by running series of experiments on REBs defect datasets from the Bearing Data Center of Case Western Reserve University (CWRU). The said test results evidence three major advantages of the novel method. First, the fault classification accuracy of the HHT-WMSC-SVM model is higher than that of HHT-SVM and ST-SVM, which is a method that combines statistical characteristics with SVM. Second, with Gauss white noise added to the original REBs defect dataset, the HHT-WMSC-SVM model maintains high classification accuracy, while the classification accuracy of ST-SVM and HHT-SVM models are significantly reduced. Third, fault classification accuracy by HHT-WMSC-SVM can exceed 95% under a Pmin range of 500–800 and a m range of 50–300 for REBs defect dataset, adding Gauss white noise at Signal Noise Ratio (SNR) = 5. Experimental results indicate that the proposed WMSC method yields a high REBs fault classification accuracy and a good performance in Gauss white noise reduction. PMID:26540059
Yu, Xiao; Ding, Enjie; Chen, Chunxu; Liu, Xiaoming; Li, Li
2015-11-03
Because roller element bearings (REBs) failures cause unexpected machinery breakdowns, their fault diagnosis has attracted considerable research attention. Established fault feature extraction methods focus on statistical characteristics of the vibration signal, which is an approach that loses sight of the continuous waveform features. Considering this weakness, this article proposes a novel feature extraction method for frequency bands, named Window Marginal Spectrum Clustering (WMSC) to select salient features from the marginal spectrum of vibration signals by Hilbert-Huang Transform (HHT). In WMSC, a sliding window is used to divide an entire HHT marginal spectrum (HMS) into window spectrums, following which Rand Index (RI) criterion of clustering method is used to evaluate each window. The windows returning higher RI values are selected to construct characteristic frequency bands (CFBs). Next, a hybrid REBs fault diagnosis is constructed, termed by its elements, HHT-WMSC-SVM (support vector machines). The effectiveness of HHT-WMSC-SVM is validated by running series of experiments on REBs defect datasets from the Bearing Data Center of Case Western Reserve University (CWRU). The said test results evidence three major advantages of the novel method. First, the fault classification accuracy of the HHT-WMSC-SVM model is higher than that of HHT-SVM and ST-SVM, which is a method that combines statistical characteristics with SVM. Second, with Gauss white noise added to the original REBs defect dataset, the HHT-WMSC-SVM model maintains high classification accuracy, while the classification accuracy of ST-SVM and HHT-SVM models are significantly reduced. Third, fault classification accuracy by HHT-WMSC-SVM can exceed 95% under a Pmin range of 500-800 and a m range of 50-300 for REBs defect dataset, adding Gauss white noise at Signal Noise Ratio (SNR) = 5. Experimental results indicate that the proposed WMSC method yields a high REBs fault classification accuracy and a good performance in Gauss white noise reduction.
NASA Technical Reports Server (NTRS)
Clegg, R. H.; Scherz, J. P.
1975-01-01
Successful aerial photography depends on aerial cameras providing acceptable photographs within cost restrictions of the job. For topographic mapping where ultimate accuracy is required only large format mapping cameras will suffice. For mapping environmental patterns of vegetation, soils, or water pollution, 9-inch cameras often exceed accuracy and cost requirements, and small formats may be better. In choosing the best camera for environmental mapping, relative capabilities and costs must be understood. This study compares resolution, photo interpretation potential, metric accuracy, and cost of 9-inch, 70mm, and 35mm cameras for obtaining simultaneous color and color infrared photography for environmental mapping purposes.
28 CFR 523.16 - Lump sum awards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... TRANSFER COMPUTATION OF SENTENCE Extra Good Time § 523.16 Lump sum awards. Any staff member may recommend to the Warden the approval of an inmate for a lump sum award of extra good time. Such recommendations... make lump sum awards of extra good time not to exceed thirty days. If the recommendation is for an...
28 CFR 523.16 - Lump sum awards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... TRANSFER COMPUTATION OF SENTENCE Extra Good Time § 523.16 Lump sum awards. Any staff member may recommend to the Warden the approval of an inmate for a lump sum award of extra good time. Such recommendations... make lump sum awards of extra good time not to exceed thirty days. If the recommendation is for an...
28 CFR 523.16 - Lump sum awards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... TRANSFER COMPUTATION OF SENTENCE Extra Good Time § 523.16 Lump sum awards. Any staff member may recommend to the Warden the approval of an inmate for a lump sum award of extra good time. Such recommendations... make lump sum awards of extra good time not to exceed thirty days. If the recommendation is for an...
28 CFR 523.16 - Lump sum awards.
Code of Federal Regulations, 2011 CFR
2011-07-01
... TRANSFER COMPUTATION OF SENTENCE Extra Good Time § 523.16 Lump sum awards. Any staff member may recommend to the Warden the approval of an inmate for a lump sum award of extra good time. Such recommendations... make lump sum awards of extra good time not to exceed thirty days. If the recommendation is for an...
28 CFR 523.16 - Lump sum awards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... TRANSFER COMPUTATION OF SENTENCE Extra Good Time § 523.16 Lump sum awards. Any staff member may recommend to the Warden the approval of an inmate for a lump sum award of extra good time. Such recommendations... make lump sum awards of extra good time not to exceed thirty days. If the recommendation is for an...
Hacker, Catrina M; Meschke, Emily X; Biederman, Irving
2018-03-20
Familiar objects, specified by name, can be identified with high accuracy when embedded in a rapidly presented sequence of images at rates exceeding 10 images/s. Not only can target objects be detected at such brief presentation rates, they can also be detected under high uncertainty, where their classification is defined negatively, e.g., "Not a Tool." The identification of a familiar speaker's voice declines precipitously when uncertainty is increased from one to a mere handful of possible speakers. Is the limitation imposed by uncertainty, i.e., the number of possible individuals, a general characteristic of processes for person individuation such that the identifiability of a familiar face would undergo a similar decline with uncertainty? Specifically, could the presence of an unnamed celebrity, thus any celebrity, be detected when presented in a rapid sequence of unfamiliar faces? If so, could the celebrity be identified? Despite the markedly greater physical similarity of faces compared to objects that are, say, not tools, the presence of a celebrity could be detected with moderately high accuracy (∼75%) at rates exceeding 7 faces/s. False alarms were exceedingly rare as almost all the errors were misses. Detection accuracy by moderate congenital prosopagnosics was lower than controls, but still well above chance. Given the detection of the presence of a celebrity, all subjects were almost always able to identify that celebrity, providing no role for a covert familiarity signal outside of awareness. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Raghu, M. S.; Basavaiah, K.; Ramesh, P. J.; Abdulrahman, Sameer A. M.; Vinay, K. B.
2012-03-01
A sensitive, precise, and cost-effective UV-spectrophotometric method is described for the determination of pheniramine maleate (PAM) in bulk drug and tablets. The method is based on the measurement of absorbance of a PAM solution in 0.1 N HCl at 264 nm. As per the International Conference on Harmonization (ICH) guidelines, the method was validated for linearity, accuracy, precision, limits of detection (LOD) and quantification (LOQ), and robustness and ruggedness. A linear relationship between absorbance and concentration of PAM in the range of 2-40 μg/ml with a correlation coefficient (r) of 0.9998 was obtained. The LOD and LOQ values were found to be 0.18 and 0.39 μg/ml PAM, respectively. The precision of the method was satisfactory: the value of relative standard deviation (RSD) did not exceed 3.47%. The proposed method was applied successfully to the determination of PAM in tablets with good accuracy and precision. Percentages of the label claims ranged from 101.8 to 102.01% with the standard deviation (SD) from 0.64 to 0.72%. The accuracy of the method was further ascertained by recovery studies via a standard addition procedure. In addition, the forced degradation of PAM was conducted in accordance with the ICH guidelines. Acidic and basic hydrolysis, thermal stress, peroxide, and photolytic degradation were used to assess the stability-indicating power of the method. A substantial degradation was observed during oxidative and alkaline degradations. No degradation was observed under other stress conditions.
Baumstark, Annette; Jendrike, Nina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido
2017-10-01
Self-monitoring of blood glucose (BG) is an essential part of diabetes therapy. Accurate and reliable results from BG monitoring systems (BGMS) are important especially when they are used to calculate insulin doses. This study aimed at assessing system accuracy of BGMS and possibly related insulin dosing errors. System accuracy of six different BGMS (Accu-Chek ® Aviva Nano, Accu-Chek Mobile, Accu-Chek Performa Nano, CONTOUR ® NEXT LINK 2.4, FreeStyle Lite, OneTouch ® Verio ® IQ) was assessed in comparison to a glucose oxidase and a hexokinase method. Study procedures and analysis were based on ISO 15197:2013/EN ISO 15197:2015, clause 6.3. In addition, insulin dosing error was modeled. In the comparison against the glucose oxidase method, five out of six BGMS fulfilled ISO 15197:2013 accuracy criteria. Up to 14.3%/4.3%/0.3% of modeled doses resulted in errors exceeding ±0.5/±1.0/±1.5 U and missing the modeled target by 20 mg/dL/40 mg/dL/60 mg/dL, respectively. Compared against the hexokinase method, five out of six BGMS fulfilled ISO 15197:2013 accuracy criteria. Up to 25.0%/10.5%/3.2% of modeled doses resulted in errors exceeding ±0.5/±1.0/±1.5 U, respectively. Differences in system accuracy were found, even among BGMS that fulfilled the minimum system accuracy criteria of ISO 15197:2013. In the error model, considerable insulin dosing errors resulted for some of the investigated systems. Diabetes patients on insulin therapy should be able to rely on their BGMS' readings; therefore, they require highly accurate BGMS, in particular, when making therapeutic decisions.
Eash, David A.
2015-01-01
An examination was conducted to understand why the 1987 single-variable RREs seem to provide better accuracy and less bias than either of the 2013 multi- or single-variable RREs. A comparison of 1-percent annual exceedance-probability regression lines for hydrologic regions 1-4 from the 1987 single-variable RREs and for flood regions 1-3 from the 2013 single-variable RREs indicates that the 1987 single-variable regional-regression lines generally have steeper slopes and lower discharges when compared to 2013 single-variable regional-regression lines for corresponding areas of Iowa. The combination of the definition of hydrologic regions, the lower discharges, and the steeper slopes of regression lines associated with the 1987 single-variable RREs seem to provide better accuracy and less bias when compared to the 2013 multi- or single-variable RREs; better accuracy and less bias was determined particularly for drainage areas less than 2 mi2, and also for some drainage areas between 2 and 20 mi2. The 2013 multi- and single-variable RREs are considered to provide better accuracy and less bias for larger drainage areas. Results of this study indicate that additional research is needed to address the curvilinear relation between drainage area and AEPDs for areas of Iowa.
Kurasawa, Shintaro; Koyama, Shouhei; Ishizawa, Hiroaki; Fujimoto, Keisaku; Chino, Shun
2017-11-23
This paper describes and verifies a non-invasive blood glucose measurement method using a fiber Bragg grating (FBG) sensor system. The FBG sensor is installed on the radial artery, and the strain (pulse wave) that is propagated from the heartbeat is measured. The measured pulse wave signal was used as a collection of feature vectors for multivariate analysis aiming to determine the blood glucose level. The time axis of the pulse wave signal was normalized by two signal processing methods: the shortest-time-cut process and 1-s-normalization process. The measurement accuracy of the calculated blood glucose level was compared with the accuracy of these signal processing methods. It was impossible to calculate a blood glucose level exceeding 200 mg/dL in the calibration curve that was constructed by the shortest-time-cut process. In the 1-s-normalization process, the measurement accuracy of the blood glucose level was improved, and a blood glucose level exceeding 200 mg/dL could be calculated. By verifying the loading vector of each calibration curve to calculate the blood glucose level with a high measurement accuracy, we found the gradient of the peak of the pulse wave at the acceleration plethysmogram greatly affected.
NASA Technical Reports Server (NTRS)
Remsberg, Ellis E.; Bhatt, Praful P.
1994-01-01
Comparisons of satellite-derived temperatures with correlative temperatures indicate that the LIMS temperatures are accurate and contain more of the needed vertical resolution for calculating a residual mean circulation for transporting tracer-like species. Generally, the LIMS temperatures are accurate to at least 2 K. Other satellite data sets are comprised of temperatures with coarser vertical resolution, leading to biases that occur with an error pattern that is characteristic of their resolution. Their biases exceed 2 K at some altitudes. Retrievals of species using an infrared limb emission technique are sensitive to any temperature bias. Generally, the IMS comparisons with other data sets for ozone and water vapor are good to better than 20 percent; this represents an independent confirmation of the quality of LIMS and temperatures. Zonal mean comparisons between LIMS and SAMS temperatures also indicate agreement to better than 2 K from about 7 to 2hPa. Therefore, we are confident that SAMS N2O and CH4 are relatively free of temperature bias in that region. These factors support the generally good agreement in G90 between model N2O transported using a LIMS-derived RMC and the N2O contours from SAMS.
Summary of paper: Area navigation implementation for a microcomputer-based Loran-C receiver
NASA Technical Reports Server (NTRS)
Oguri, Fujiko
1987-01-01
The development of an area navigation program and the implementation of this software on a microcomputer-based Loran-C receiver to provide high-quality, practical area navigation information for general aviation are described. This software provides range and bearing angle to a selected waypoint, cross-track error, course deviation indication (CDI), ground speed, and estimated time of arrival at the waypoint. The range/bearing calculation, using an elliptical Earth model, provides very good accuracy; the error does not exceed more than -.012 nm (range) or 0.09 degree (bearing) for a maximum range to 530 nm. The alpha-beta filtering is applied in order to reduce the random noise on Loran-C raw data and in the ground speed calculation. Due to alpha-beta filtering, the ground speed calculation has good stability for constant or low-accelerative flight. The execution time of this software is approximately 0.2 second. Flight testing was done with a prototype Loran-C front-end receiver, with the Loran-C area navigation software demonstrating the ability to provide navigation for the pilot to any point in the Loran-C coverage area in true area navigation fashion without line-of-sight and range restriction typical of VOR area navigation.
21 CFR 184.1143 - Ammonium sulfate.
Code of Federal Regulations, 2010 CFR
2010-04-01
... chapter, and processing aid as defined in § 170.3(o)(24) of this chapter. (d) The ingredient is used in food at levels not to exceed good manufacturing practice in accordance with § 184.1(b)(1). Current good manufacturing practice results in a maximum level, as served, of 0.15 percent for baked goods as defined in...
Imputation of missing data in time series for air pollutants
NASA Astrophysics Data System (ADS)
Junger, W. L.; Ponce de Leon, A.
2015-02-01
Missing data are major concerns in epidemiological studies of the health effects of environmental air pollutants. This article presents an imputation-based method that is suitable for multivariate time series data, which uses the EM algorithm under the assumption of normal distribution. Different approaches are considered for filtering the temporal component. A simulation study was performed to assess validity and performance of proposed method in comparison with some frequently used methods. Simulations showed that when the amount of missing data was as low as 5%, the complete data analysis yielded satisfactory results regardless of the generating mechanism of the missing data, whereas the validity began to degenerate when the proportion of missing values exceeded 10%. The proposed imputation method exhibited good accuracy and precision in different settings with respect to the patterns of missing observations. Most of the imputations obtained valid results, even under missing not at random. The methods proposed in this study are implemented as a package called mtsdi for the statistical software system R.
Non-hydrostatic semi-elastic hybrid-coordinate SISL extension of HIRLAM. Part II: numerical testing
NASA Astrophysics Data System (ADS)
Rõõm, Rein; Männik, Aarne; Luhamaa, Andres; Zirk, Marko
2007-10-01
The semi-implicit semi-Lagrangian (SISL), two-time-level, non-hydrostatic numerical scheme, based on the non-hydrostatic, semi-elastic pressure-coordinate equations, is tested in model experiments with flow over given orography (elliptical hill, mountain ridge, system of successive ridges) in a rectangular domain with emphasis on the numerical accuracy and non-hydrostatic effect presentation capability. Comparison demonstrates good (in strong primary wave generation) to satisfactory (in weak secondary wave reproduction in some cases) consistency of the numerical modelling results with known stationary linear test solutions. Numerical stability of the developed model is investigated with respect to the reference state choice, modelling dynamics of a stationary front. The horizontally area-mean reference temperature proves to be the optimal stability warrant. The numerical scheme with explicit residual in the vertical forcing term becomes unstable for cross-frontal temperature differences exceeding 30 K. Stability is restored, if the vertical forcing is treated implicitly, which enables to use time steps, comparable with the hydrostatic SISL.
A simple method for the enrichment of bisphenols using boron nitride.
Fischnaller, Martin; Bakry, Rania; Bonn, Günther K
2016-03-01
A simple solid-phase extraction method for the enrichment of 5 bisphenol derivatives using hexagonal boron nitride (BN) was developed. BN was applied to concentrate bisphenol derivatives in spiked water samples and the compounds were analyzed using HPLC coupled to fluorescence detection. The effect of pH and organic solvents on the extraction efficiency was investigated. An enrichment factor up to 100 was achieved without evaporation and reconstitution. The developed method was applied for the determination of bisphenol A migrated from some polycarbonate plastic products. Furthermore, bisphenol derivatives were analyzed in spiked and non-spiked canned food and beverages. None of the analyzed samples exceeded the migration limit set by the European Union of 0.6mg/kg food. The method showed good recovery rates ranging from 80% to 110%. Validation of the method was performed in terms of accuracy and precision. The applied method is robust, fast, efficient and easily adaptable to different analytical problems. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Tumanov, Sergiu
A test of goodness of fit based on rank statistics was applied to prove the applicability of the Eggenberger-Polya discrete probability law to hourly SO 2-concentrations measured in the vicinity of single sources. With this end in view, the pollutant concentration was considered an integral quantity which may be accepted if one properly chooses the unit of measurement (in this case μg m -3) and if account is taken of the limited accuracy of measurements. The results of the test being satisfactory, even in the range of upper quantiles, the Eggenberger-Polya law was used in association with numerical modelling to estimate statistical parameters, e.g. quantiles, cumulative probabilities of threshold concentrations to be exceeded, and so on, in the grid points of a network covering the area of interest. This only needs accurate estimations of means and variances of the concentration series which can readily be obtained through routine air pollution dispersion modelling.
40 CFR 92.127 - Emission measurement accuracy.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...
40 CFR 92.127 - Emission measurement accuracy.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...
40 CFR 92.127 - Emission measurement accuracy.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...
40 CFR 92.127 - Emission measurement accuracy.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...
40 CFR 92.127 - Emission measurement accuracy.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Emission measurement accuracy. (a) Good engineering practice dictates that exhaust emission sample analyzer... resolution read-out systems such as computers, data loggers, etc., can provide sufficient accuracy and...
40 CFR 89.310 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2010 CFR
2010-07-01
... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...
40 CFR 89.310 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2011 CFR
2011-07-01
... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...
40 CFR 89.310 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2013 CFR
2013-07-01
... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...
40 CFR 89.310 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2012 CFR
2012-07-01
... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...
40 CFR 89.310 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2014 CFR
2014-07-01
... to § 89.323. (c) Emission measurement accuracy—Bag sampling. (1) Good engineering practice dictates... generally not be used. (2) Some high resolution read-out systems, such as computers, data loggers, and so..., using good engineering judgement, below 15 percent of full scale are made to ensure the accuracy of the...
40 CFR 180.1153 - Lepidopteran pheromones; exemption from the requirement of a tolerance.
Code of Federal Regulations, 2013 CFR
2013-07-01
... rate not to exceed 150 grams active ingredient/acre/year in accordance with good agricultural practices; and applied as a post-harvest treatment to stored food commodities at a rate not to exceed 3.5 grams active ingredient/1,000 ft2/year (equivalent to 150 grams active ingredient/acre/year) in accordance with...
40 CFR 180.1153 - Lepidopteran pheromones; exemption from the requirement of a tolerance.
Code of Federal Regulations, 2014 CFR
2014-07-01
... rate not to exceed 150 grams active ingredient/acre/year in accordance with good agricultural practices; and applied as a post-harvest treatment to stored food commodities at a rate not to exceed 3.5 grams active ingredient/1,000 ft2/year (equivalent to 150 grams active ingredient/acre/year) in accordance with...
40 CFR 180.1153 - Lepidopteran pheromones; exemption from the requirement of a tolerance.
Code of Federal Regulations, 2011 CFR
2011-07-01
... rate not to exceed 150 grams active ingredient/acre/year in accordance with good agricultural practices; and applied as a post-harvest treatment to stored food commodities at a rate not to exceed 3.5 grams active ingredient/1,000 ft2/year (equivalent to 150 grams active ingredient/acre/year) in accordance with...
40 CFR 180.1153 - Lepidopteran pheromones; exemption from the requirement of a tolerance.
Code of Federal Regulations, 2012 CFR
2012-07-01
... rate not to exceed 150 grams active ingredient/acre/year in accordance with good agricultural practices; and applied as a post-harvest treatment to stored food commodities at a rate not to exceed 3.5 grams active ingredient/1,000 ft2/year (equivalent to 150 grams active ingredient/acre/year) in accordance with...
40 CFR 180.1153 - Lepidopteran pheromones; exemption from the requirement of a tolerance.
Code of Federal Regulations, 2010 CFR
2010-07-01
... rate not to exceed 150 grams active ingredient/acre/year in accordance with good agricultural practices; and applied as a post-harvest treatment to stored food commodities at a rate not to exceed 3.5 grams active ingredient/1,000 ft2/year (equivalent to 150 grams active ingredient/acre/year) in accordance with...
Giltrap, M; Ronan, J; Hardenberg, S; Parkes, G; McHugh, B; McGovern, E; Wilson, J G
2013-06-15
Candidate OSPAR/ICES recommended biomarkers at the level of the individual in Mytilus edulis for determination of good environmental status for MSFD were evaluated against contaminant levels at sites around Ireland. The sites chosen ranged from moderate to low pollution levels, but the actual ranking of the sites varied according to the contaminant levels present. At the most contaminated site, Cork, 4 out of 16 contaminants exceeded the EAC, while at Shannon, no EACs were exceeded. The SOS assay suggested that Cork was the healthiest site with a LT50 of 17.6 days, while SOS for Shannon was 15.6 days. Likewise, condition factors varied among sites and did not always correspond to contaminant-based status. There may be uncertainty in assigning status around the not good:good boundary. This raises potential difficulties not only in the biomarker/contaminant load relationship but also in the reliability of the biomarkers themselves and hence barriers meeting compliance levels. Copyright © 2013 Elsevier Ltd. All rights reserved.
Simple and conditional visual discrimination with wheel running as reinforcement in rats.
Iversen, I H
1998-09-01
Three experiments explored whether access to wheel running is sufficient as reinforcement to establish and maintain simple and conditional visual discriminations in nondeprived rats. In Experiment 1, 2 rats learned to press a lit key to produce access to running; responding was virtually absent when the key was dark, but latencies to respond were longer than for customary food and water reinforcers. Increases in the intertrial interval did not improve the discrimination performance. In Experiment 2, 3 rats acquired a go-left/go-right discrimination with a trial-initiating response and reached an accuracy that exceeded 80%; when two keys showed a steady light, pressing the left key produced access to running whereas pressing the right key produced access to running when both keys showed blinking light. Latencies to respond to the lights shortened when the trial-initiation response was introduced and became much shorter than in Experiment 1. In Experiment 3, 1 rat acquired a conditional discrimination task (matching to sample) with steady versus blinking lights at an accuracy exceeding 80%. A trial-initiation response allowed self-paced trials as in Experiment 2. When the rat was exposed to the task for 19 successive 24-hr periods with access to food and water, the discrimination performance settled in a typical circadian pattern and peak accuracy exceeded 90%. When the trial-initiation response was under extinction, without access to running, the circadian activity pattern determined the time of spontaneous recovery. The experiments demonstrate that wheel-running reinforcement can be used to establish and maintain simple and conditional visual discriminations in nondeprived rats.
NASA Technical Reports Server (NTRS)
Bryant, N. A.; Zobrist, A. L.; Walker, R. E.; Gokhman, B.
1985-01-01
Performance requirements regarding geometric accuracy have been defined in terms of end product goals, but until recently no precise details have been given concerning the conditions under which that accuracy is to be achieved. In order to achieve higher spatial and spectral resolutions, the Thematic Mapper (TM) sensor was designed to image in both forward and reverse mirror sweeps in two separate focal planes. Both hardware and software have been augmented and changed during the course of the Landsat TM developments to achieve improved geometric accuracy. An investigation has been conducted to determine if the TM meets the National Map Accuracy Standards for geometric accuracy at larger scales. It was found that TM imagery, in terms of geometry, has come close to, and in some cases exceeded, its stringent specifications.
21 CFR 184.1139 - Ammonium hydroxide.
Code of Federal Regulations, 2010 CFR
2010-04-01
... this chapter; a surface-finishing agent as defined in § 170.3(o)(30) of this chapter; and as a boiler... additive at levels not to exceed current good manufacturing practice. (d) Prior sanctions for this... used in food with no limitation other than current good manufacturing practice. The affirmation of this...
21 CFR 184.1139 - Ammonium hydroxide.
Code of Federal Regulations, 2011 CFR
2011-04-01
... this chapter; a surface-finishing agent as defined in § 170.3(o)(30) of this chapter; and as a boiler... additive at levels not to exceed current good manufacturing practice. (d) Prior sanctions for this... used in food with no limitation other than current good manufacturing practice. The affirmation of this...
21 CFR 184.1139 - Ammonium hydroxide.
Code of Federal Regulations, 2012 CFR
2012-04-01
... this chapter; a surface-finishing agent as defined in § 170.3(o)(30) of this chapter; and as a boiler... additive at levels not to exceed current good manufacturing practice. (d) Prior sanctions for this... used in food with no limitation other than current good manufacturing practice. The affirmation of this...
21 CFR 184.1139 - Ammonium hydroxide.
Code of Federal Regulations, 2013 CFR
2013-04-01
... this chapter; a surface-finishing agent as defined in § 170.3(o)(30) of this chapter; and as a boiler... additive at levels not to exceed current good manufacturing practice. (d) Prior sanctions for this... used in food with no limitation other than current good manufacturing practice. The affirmation of this...
21 CFR 184.1676 - Pyridoxine hydrochloride.
Code of Federal Regulations, 2011 CFR
2011-04-01
... hydrochloride that is prepared by chemical synthesis. (b) The ingredient meets the specifications of the Food... manufacturing practice conditions of use: (1) The ingredient is used as a nutrient supplement as defined in... exceed current good manufacturing practice: baked goods as defined in § 170.3(n)(1) of this chapter...
Code of Federal Regulations, 2014 CFR
2014-04-01
... is used in baked goods and baking mixes, the amount of the additive is not to exceed 0.5 percent by weight of ready-to-bake products or of finished formulations prior to baking. Generally recognized as safe (GRAS) ingredients or food additives approved for use in baked goods shall be used in combination...
11 CFR 9008.9 - Receipt of goods and services from commercial vendors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... for promotional consideration. (1) A commercial vendor may provide goods or services in exchange for promotional consideration provided that doing so is in the ordinary course of business. (2) The provision of... shall not exceed the commercial benefit reasonably expected to be derived from the unique promotional...
21 CFR 184.1560 - Ox bile extract.
Code of Federal Regulations, 2010 CFR
2010-04-01
... known as purified oxgall or sodium choleate, is a yellowish green, soft solid, with a partly sweet... evaporating the alcohol extract of concentrated bile. (b) Food-grade ox bile extract shall meet the... with § 184.1(b)(1) at levels not to exceed good manufacturing practice. Current good manufacturing...
19 CFR 10.586 - Certification not required.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE...-United States Free Trade Agreement Import Requirements § 10.586 Certification not required. (a) General... good; or (2) A commercial importation for which the value of the originating goods does not exceed U.S...
Accuracy and reliability of the Pfeffer Questionnaire for the Brazilian elderly population
Dutra, Marina Carneiro; Ribeiro, Raynan dos Santos; Pinheiro, Sarah Brandão; de Melo, Gislane Ferreira; Carvalho, Gustavo de Azevedo
2015-01-01
The aging population calls for instruments to assess functional and cognitive impairment in the elderly, aiming to prevent conditions that affect functional abilities. Objective To verify the accuracy and reliability of the Pfeffer (FAQ) scale for the Brazilian elderly population and to evaluate the reliability and reproducibility of the translated version of the Pfeffer Questionnaire. Methods The Brazilian version of the FAQ was applied to 110 elderly divided into two groups. Both groups were assessed by two blinded investigators at baseline and again after 15 days. In order to verify the accuracy and reliability of the instrument, sensitivity and specificity measurements for the presence or absence of functional and cognitive decline were calculated for various cut-off points and the ROC curve. Intra and inter-examiner reliability were assessed using the Interclass Correlation Coefficient (ICC) and Bland-Altman plots. Results For the occurrence of cognitive decline, the ROC curve yielded an area under the curve of 0.909 (95%CI of 0.845 to 0.972), sensitivity of 75.68% (95%CI of 93.52% to 100%) and specificity of 97.26%. For the occurrence of functional decline, the ROC curve yielded an area under the curve of 0.851 (95%CI of 64.52% to 87.33%) and specificity of 80.36% (95%CI of 69.95% to 90.76%). The ICC was excellent, with all values exceeding 0.75. On the Bland-Altman plot, intra-examiner agreement was good, with p>0.05consistently close to 0. A systematic difference was found for inter-examiner agreement. Conclusion The Pfeffer Questionnaire is applicable in the Brazilian elderly population and showed reliability and reproducibility compared to the original test. PMID:29213959
NASA Astrophysics Data System (ADS)
Huang, Q. Z.; Hsu, S. Y.; Li, M. H.
2016-12-01
The long-term streamflow prediction is important not only to estimate water-storage of a reservoir but also to the surface water intakes, which supply people's livelihood, agriculture, and industry. Climatology forecasts of streamflow have been traditionally used for calculating the exceedance probability curve of streamflow and water resource management. In this study, we proposed a stochastic approach to predict the exceedance probability curve of long-term streamflow with the seasonal weather outlook from Central Weather Bureau (CWB), Taiwan. The approach incorporates a statistical downscale weather generator and a catchment-scale hydrological model to convert the monthly outlook into daily rainfall and temperature series and to simulate the streamflow based on the outlook information. Moreover, we applied Bayes' theorem to derive a method for calculating the exceedance probability curve of the reservoir inflow based on the seasonal weather outlook and its imperfection. The results show that our approach can give the exceedance probability curves reflecting the three-month weather outlook and its accuracy. We also show how the improvement of the weather outlook affects the predicted exceedance probability curves of the streamflow. Our approach should be useful for the seasonal planning and management of water resource and their risk assessment.
Method of the active contour for segmentation of bone systems on bitmap images
NASA Astrophysics Data System (ADS)
Vu, Hai Anh; Safonov, Roman A.; Kolesnikova, Anna S.; Kirillova, Irina V.; Kossovich, Leonid U.
2018-02-01
It is developed within a method of the active contours the approach, which is allowing to realize separation of a contour of a object of the image in case of its segmentation. This approach exceeds a parametric method on speed, but also does not concede to it on decision accuracy. The approach is offered within this operation will allow to realize allotment of a contour with high accuracy of the image and quicker than a parametric method of the active contours.
SSC Geopositional Assessment of the Advanced Wide Field Sensor
NASA Technical Reports Server (NTRS)
Ross, Kenton
2007-01-01
The objective is to provide independent verification of IRS geopositional accuracy claims and of the internal geopositional characterization provided by Lutes (2005). Six sub-scenes (quads) were assessed; Three from each AWiFS camera. Check points were manually matched to digital orthophoto quarter quadrangle (DOQQ) reference (assumed accuracy approx. 5 m, RMSE) Check points were selected to meet or exceed Federal Geographic Data Committee's guidelines. Used ESRI ArcGIS for data collection and SSC-written MATLAB scripts for data analysis.
Code of Federal Regulations, 2010 CFR
2010-04-01
... accepting proof of support or application for a lump-sum death payment. (a) When evidence of good cause is... death payment. You may be asked for evidence of good cause for these delays if— (1) You are the insured... limits on accepting proof of support or application for a lump-sum death payment. 404.780 Section 404.780...
Iceland: Eyjafjallajökull Volcano
Atmospheric Science Data Center
2013-04-17
... plume height map, which is retrieved at 1.1 kilometer (0.68 mile) horizontal resolution, and with vertical accuracy of about half a ... the plume reaches altitudes exceeding 8 kilometers (26,247 feet), descending to about 6 kilometers (19,685 feet) about 250 kilometers (155 ...
Communication Accuracy in Magazine Science Reporting.
ERIC Educational Resources Information Center
Borman, Susan Cray
1978-01-01
Evaluators with scientific expertise who analyzed the accuracy of popularized science news in mass circulation magazines found that the over-all accuracy of the magazine articles was good, and that the major problem was the omission of relevant information. (GW)
Amperometric Glucose Sensors: Sources of Error and Potential Benefit of Redundancy
Castle, Jessica R.; Kenneth Ward, W.
2010-01-01
Amperometric glucose sensors have advanced the care of patients with diabetes and are being studied to control insulin delivery in the research setting. However, at times, currently available sensors demonstrate suboptimal accuracy, which can result from calibration error, sensor drift, or lag. Inaccuracy can be particularly problematic in a closed-loop glycemic control system. In such a system, the use of two sensors allows selection of the more accurate sensor as the input to the controller. In our studies in subjects with type 1 diabetes, the accuracy of the better of two sensors significantly exceeded the accuracy of a single, randomly selected sensor. If an array with three or more sensors were available, it would likely allow even better accuracy with the use of voting. PMID:20167187
Field-of-View Guiding Camera on the HISAKI (SPRINT-A) Satellite
NASA Astrophysics Data System (ADS)
Yamazaki, A.; Tsuchiya, F.; Sakanoi, T.; Uemizu, K.; Yoshioka, K.; Murakami, G.; Kagitani, M.; Kasaba, Y.; Yoshikawa, I.; Terada, N.; Kimura, T.; Sakai, S.; Nakaya, K.; Fukuda, S.; Sawai, S.
2014-11-01
HISAKI (SPRINT-A) satellite is an earth-orbiting Extreme UltraViolet (EUV) spectroscopic mission and launched on 14 Sep. 2013 by the launch vehicle Epsilon-1. Extreme ultraviolet spectroscope (EXCEED) onboard the satellite will investigate plasma dynamics in Jupiter's inner magnetosphere and atmospheric escape from Venus and Mars. EUV spectroscopy is useful to measure electron density and temperature and ion composition in plasma environment. EXCEED also has an advantage to measure spatial distribution of plasmas around the planets. To measure radial plasma distribution in the Jovian inner magnetosphere and plasma emissions from ionosphere, exosphere and tail separately (for Venus and Mars), the pointing accuracy of the spectroscope should be smaller than spatial structures of interest (20 arc-seconds). For satellites in the low earth orbit (LEO), the pointing displacement is generally caused by change of alignment between the satellite bus module and the telescope due to the changing thermal inputs from the Sun and Earth. The HISAKI satellite is designed to compensate the displacement by tracking the target with using a Field-Of-View (FOV) guiding camera. Initial checkout of the attitude control for the EXCEED observation shows that pointing accuracy kept within 2 arc-seconds in a case of "track mode" which is used for Jupiter observation. For observations of Mercury, Venus, Mars, and Saturn, the entire disk will be guided inside slit to observe plasma around the planets. Since the FOV camera does not capture the disk in this case, the satellite uses a star tracker (STT) to hold the attitude ("hold mode"). Pointing accuracy during this mode has been 20-25 arc-seconds. It has been confirmed that the attitude control works well as designed.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., CAS Reg. No. of DL-form 617-48-1) is the common name for 1-hydroxy-1, 2-ethanedicarboxylic acid. L... ingredients are used in food, except baby food, at levels not to exceed good manufacturing practice in accordance with § 184.1(b)(1). Current good manufacturing practice results in a maximum level, as served, of...
Code of Federal Regulations, 2010 CFR
2010-04-01
..., CAS Reg. No. of DL-form 617-48-1) is the common name for 1-hydroxy-1, 2-ethanedicarboxylic acid. L... ingredients are used in food, except baby food, at levels not to exceed good manufacturing practice in accordance with § 184.1(b)(1). Current good manufacturing practice results in a maximum level, as served, of...
21 CFR 184.1676 - Pyridoxine hydrochloride.
Code of Federal Regulations, 2014 CFR
2014-04-01
... exceed current good manufacturing practice: baked goods as defined in § 170.3(n)(1) of this chapter...)(31) of this chapter; plant protein products as defined in § 170.3(n)(33) of this chapter; and snack... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Pyridoxine hydrochloride. 184.1676 Section 184...
Characterizing artifacts in RR stress test time series.
Astudillo-Salinas, Fabian; Palacio-Baus, Kenneth; Solano-Quinde, Lizandro; Medina, Ruben; Wong, Sara
2016-08-01
Electrocardiographic stress test records have a lot of artifacts. In this paper we explore a simple method to characterize the amount of artifacts present in unprocessed RR stress test time series. Four time series classes were defined: Very good lead, Good lead, Low quality lead and Useless lead. 65 ECG, 8 lead, records of stress test series were analyzed. Firstly, RR-time series were annotated by two experts. The automatic methodology is based on dividing the RR-time series in non-overlapping windows. Each window is marked as noisy whenever it exceeds an established standard deviation threshold (SDT). Series are classified according to the percentage of windows that exceeds a given value, based upon the first manual annotation. Different SDT were explored. Results show that SDT close to 20% (as a percentage of the mean) provides the best results. The coincidence between annotators classification is 70.77% whereas, the coincidence between the second annotator and the automatic method providing the best matches is larger than 63%. Leads classified as Very good leads and Good leads could be combined to improve automatic heartbeat labeling.
Perspectives of Maine Forest Cover Change from Landsat Imagery and Forest Inventory Analysis (FIA)
Steven Sader; Michael Hoppus; Jacob Metzler; Suming Jin
2005-01-01
A forest change detection map was developed to document forest gains and losses during the decade of the 1990s. The effectiveness of the Landsat imagery and methods for detecting Maine forest cover change are indicated by the good accuracy assessment results: forest-no change, forest loss, and forest gain accuracy were 90, 88, and 92% respectively, and the good...
Four years of Landsat-7 on-orbit geometric calibration and performance
Lee, D.S.; Storey, James C.; Choate, M.J.; Hayes, R.W.
2004-01-01
Unlike its predecessors, Landsat-7 has undergone regular geometric and radiometric performance monitoring and calibration since launch in April 1999. This ongoing activity, which includes issuing quarterly updates to calibration parameters, has generated a wealth of geometric performance data over the four-year on-orbit period of operations. A suite of geometric characterization (measurement and evaluation procedures) and calibration (procedures to derive improved estimates of instrument parameters) methods are employed by the Landsat-7 Image Assessment System to maintain the geometric calibration and to track specific aspects of geometric performance. These include geodetic accuracy, band-to-band registration accuracy, and image-to-image registration accuracy. These characterization and calibration activities maintain image product geometric accuracy at a high level - by monitoring performance to determine when calibration is necessary, generating new calibration parameters, and verifying that new parameters achieve desired improvements in accuracy. Landsat-7 continues to meet and exceed all geometric accuracy requirements, although aging components have begun to affect performance.
McQueen, Robert Brett; Breton, Marc D; Craig, Joyce; Holmes, Hayden; Whittington, Melanie D; Ott, Markus A; Campbell, Jonathan D
2018-04-01
The objective was to model clinical and economic outcomes of self-monitoring blood glucose (SMBG) devices with varying error ranges and strip prices for type 1 and insulin-treated type 2 diabetes patients in England. We programmed a simulation model that included separate risk and complication estimates by type of diabetes and evidence from in silico modeling validated by the Food and Drug Administration. Changes in SMBG error were associated with changes in hemoglobin A1c (HbA1c) and separately, changes in hypoglycemia. Markov cohort simulation estimated clinical and economic outcomes. A SMBG device with 8.4% error and strip price of £0.30 (exceeding accuracy requirements by International Organization for Standardization [ISO] 15197:2013/EN ISO 15197:2015) was compared to a device with 15% error (accuracy meeting ISO 15197:2013/EN ISO 15197:2015) and price of £0.20. Outcomes were lifetime costs, quality-adjusted life years (QALYs) and incremental cost-effectiveness ratios (ICERs). With SMBG errors associated with changes in HbA1c only, the ICER was £3064 per QALY in type 1 diabetes and £264 668 per QALY in insulin-treated type 2 diabetes for an SMBG device with 8.4% versus 15% error. With SMBG errors associated with hypoglycemic events only, the device exceeding accuracy requirements was cost-saving and more effective in insulin-treated type 1 and type 2 diabetes. Investment in devices with higher strip prices but improved accuracy (less error) appears to be an efficient strategy for insulin-treated diabetes patients at high risk of severe hypoglycemia.
a Band Selection Method for High Precision Registration of Hyperspectral Image
NASA Astrophysics Data System (ADS)
Yang, H.; Li, X.
2018-04-01
During the registration of hyperspectral images and high spatial resolution images, too much bands in a hyperspectral image make it difficult to select bands with good registration performance. Terrible bands are possible to reduce matching speed and accuracy. To solve this problem, an algorithm based on Cram'er-Rao lower bound theory is proposed to select good matching bands in this paper. The algorithm applies the Cram'er-Rao lower bound theory to the study of registration accuracy, and selects good matching bands by CRLB parameters. Experiments show that the algorithm in this paper can choose good matching bands and provide better data for the registration of hyperspectral image and high spatial resolution image.
OBIA based hierarchical image classification for industrial lake water.
Uca Avci, Z D; Karaman, M; Ozelkan, E; Kumral, M; Budakoglu, M
2014-07-15
Water management is very important in water mining regions for the sustainability of the natural environment and for industrial activities. This study focused on Acigol Lake, which is an important wetland for sodium sulphate (Na2SO4) production, a significant natural protection area and habitat for local bird species and endemic species of this saline environment, and a stopover for migrating flamingos. By a hierarchical classification method, ponds representing the industrial part were classified according to in-situ measured Baumé values, and lake water representing the natural part was classified according to in-situ measurements of water depth. The latter is directly related to the water level, which should not exceed a critical level determined by the regulatory authorities. The resulting data, produced at an accuracy of around 80%, illustrates the status in two main regions for a single date. The output of the analysis may be meaningful for firms and environmental researchers, and authorizations can provide a good perspective for decision making for sustainable resource management in the region which has uncommon and specific ecological characteristics. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Petrovskii, Sergei; Petrovskaya, Natalia; Bearup, Daniel
2014-09-01
Pest insects pose a significant threat to food production worldwide resulting in annual losses worth hundreds of billions of dollars. Pest control attempts to prevent pest outbreaks that could otherwise destroy a sward. It is good practice in integrated pest management to recommend control actions (usually pesticides application) only when the pest density exceeds a certain threshold. Accurate estimation of pest population density in ecosystems, especially in agro-ecosystems, is therefore very important, and this is the overall goal of the pest insect monitoring. However, this is a complex and challenging task; providing accurate information about pest abundance is hardly possible without taking into account the complexity of ecosystems' dynamics, in particular, the existence of multiple scales. In the case of pest insects, monitoring has three different spatial scales, each of them having their own scale-specific goal and their own approaches to data collection and interpretation. In this paper, we review recent progress in mathematical models and methods applied at each of these scales and show how it helps to improve the accuracy and robustness of pest population density estimation.
Method of low tantalum amounts determination in niobium and its compounds by ICP-OES technique.
Smolik, Marek; Turkowska, Magdalena
2013-10-15
A method of determination of low amounts of tantalum in niobium and niobium compounds without its prior separation by means of inductively coupled plasma optical emission spectrometry (ICP-OES) has been worked out. The method involves dissolution of the analyzed samples of niobium as well as its various compounds (oxides, fluorides, chlorides, niobates(V)) in fluoride environments, precipitation of sparingly soluble niobic(tantalic) acid (Nb2O5(Ta2O5) · xH2O), converting them into soluble complex compounds by means of oxalic acid with addition of hydrogen peroxide and finally analyzing directly obtained solutions by ICP-OES. This method permits determination of Ta in niobium at the level of 10(-3)% with relatively good precision (≤ 8% RSD) and accuracy (recovery factor: 0.9-1.1). Relative differences in the results obtained by two independent methods (ICP-OES and ICP-MS) do not exceed 14%, and other elements present in niobium compounds (Ti, W, Zr, Hf, V, Mo, Fe, Cr) at the level of 10(-2)% do not affect determination. © 2013 Elsevier B.V. All rights reserved.
An Automated Method for Landmark Identification and Finite-Element Modeling of the Lumbar Spine.
Campbell, Julius Quinn; Petrella, Anthony J
2015-11-01
The purpose of this study was to develop a method for the automated creation of finite-element models of the lumbar spine. Custom scripts were written to extract bone landmarks of lumbar vertebrae and assemble L1-L5 finite-element models. End-plate borders, ligament attachment points, and facet surfaces were identified. Landmarks were identified to maintain mesh correspondence between meshes for later use in statistical shape modeling. 90 lumbar vertebrae were processed creating 18 subject-specific finite-element models. Finite-element model surfaces and ligament attachment points were reproduced within 1e-5 mm of the bone surface, including the critical contact surfaces of the facets. Element quality exceeded specifications in 97% of elements for the 18 models created. The current method is capable of producing subject-specific finite-element models of the lumbar spine with good accuracy, quality, and robustness. The automated methods developed represent advancement in the state of the art of subject-specific lumbar spine modeling to a scale not possible with prior manual and semiautomated methods.
Wireless Sensor-Based Smart-Clothing Platform for ECG Monitoring
Lin, Chung-Chih; Yu, Yan-Shuo
2015-01-01
The goal of this study is to use wireless sensor technologies to develop a smart clothes service platform for health monitoring. Our platform consists of smart clothes, a sensor node, a gateway server, and a health cloud. The smart clothes have fabric electrodes to detect electrocardiography (ECG) signals. The sensor node improves the accuracy of QRS complexes detection by morphology analysis and reduces power consumption by the power-saving transmission functionality. The gateway server provides a reconfigurable finite state machine (RFSM) software architecture for abnormal ECG detection to support online updating. Most normal ECG can be filtered out, and the abnormal ECG is further analyzed in the health cloud. Three experiments are conducted to evaluate the platform's performance. The results demonstrate that the signal-to-noise ratio (SNR) of the smart clothes exceeds 37 dB, which is within the “very good signal” interval. The average of the QRS sensitivity and positive prediction is above 99.5%. Power-saving transmission is reduced by nearly 1980 times the power consumption in the best-case analysis. PMID:26640512
Wireless Sensor-Based Smart-Clothing Platform for ECG Monitoring.
Wang, Jie; Lin, Chung-Chih; Yu, Yan-Shuo; Yu, Tsang-Chu
2015-01-01
The goal of this study is to use wireless sensor technologies to develop a smart clothes service platform for health monitoring. Our platform consists of smart clothes, a sensor node, a gateway server, and a health cloud. The smart clothes have fabric electrodes to detect electrocardiography (ECG) signals. The sensor node improves the accuracy of QRS complexes detection by morphology analysis and reduces power consumption by the power-saving transmission functionality. The gateway server provides a reconfigurable finite state machine (RFSM) software architecture for abnormal ECG detection to support online updating. Most normal ECG can be filtered out, and the abnormal ECG is further analyzed in the health cloud. Three experiments are conducted to evaluate the platform's performance. The results demonstrate that the signal-to-noise ratio (SNR) of the smart clothes exceeds 37 dB, which is within the "very good signal" interval. The average of the QRS sensitivity and positive prediction is above 99.5%. Power-saving transmission is reduced by nearly 1980 times the power consumption in the best-case analysis.
Nilsson, M; Birnbaum, S; Wahlund, K G
1996-10-15
The 30S and 50S subunits and the 70S ribosome of Escherichia coli were separated in 6 minutes by using asymmetrical flow field-flow fractionation (FFF). The total analysis time for determination of the relative amounts of ribosomes and free subunits in a preparation from a cell suspension was 8 min. The method can detect a change in the mass fraction of ribosomes if it exceeds approx, 10%. The separation is based on differences in diffusion coefficients, i.e., hydrodynamic diameters, and these can be determined from observed retention times. The hydrodynamic diameters were in good agreement with literature values obtained from electron microscopy. The mass fraction of ribosomes changed as a function of the magnesium ion concentration which confirms previous knowledge and shows the accuracy of the method. The method appears as an alternative to ultracentrifugation analysis and avoids some of its drawbacks and artefacts. An obvious application can be the optimisation of cell design in metabolic engineering in order to maximise translation and protein production.
Li-Tsang, Cecilia W P; Wong, Agnes S K; Leung, Howard W H; Cheng, Joyce S; Chiu, Billy H W; Tse, Linda F L; Chung, Raymond C K
2013-09-01
There are more children diagnosed with specific learning difficulties in recent years as people are more aware of these conditions. Diagnostic tool has been validated to screen out this condition from the population (SpLD test for Hong Kong children). However, for specific assessment on handwriting problem, there seems a lack of standardized and objective evaluation tool to look into the problems. The objective of this study was to validate the Chinese Handwriting Analysis System (CHAS), which is designed to measure both the process and production of handwriting. The construct validity, convergent validity, internal consistency and test-retest reliability of CHAS was analyzed using the data from 734 grade 1-6 students from 6 primary schools in Hong Kong. Principal Component Analysis revealed that measurements of CHAS loaded into 4 components which accounted for 77.73% of the variance. The correlation between the handwriting accuracy obtained from HAS and eyeballing was r=.73. Cronbach's alpha of all measurement items was .65. Except SD of writing time per character, all the measurement items regarding handwriting speed, handwriting accuracy and pen pressure showed good to excellent test-retest reliability (r=.72-.96), while measurement on the numbers of characters which exceeded grid showed moderate reliability (r=.48). Although there are still ergonomic, biomechanical or unspecified aspects which may not be determined by the system, the CHAS can definitely assist therapists in identifying primary school students with handwriting problems and implement interventions accordingly. Copyright © 2013 Elsevier Ltd. All rights reserved.
Multiclass method for the determination of 62 antibiotics in milk.
Moretti, Simone; Cruciani, Gabriele; Romanelli, Sara; Rossi, Rosanna; Saluti, Giorgio; Galarini, Roberta
2016-09-01
A multiclass method for screening and confirmatory analysis of antimicrobial residues in milk has been developed and validated. Sixty-two antibiotics belonging to ten different drug families (amphenicols, cephalosporins, lincosamides, macrolides, penicillin, pleuromutilins, quinolones, rifamycins, sulfonamides and tetracyclines) have been included. After the addition of an aqueous solution of EDTA, the milk samples were extracted twice with acetonitrile, evaporated and dissolved in ammonium acetate. After centrifugation, 10 µl were analysed using LC-Q-Orbitrap operating in positive electrospray ionization mode. The method was validated in bovine milk in the range 2-150 µg kg(-1) for all antibiotics; for four compounds with maximum residue limits higher than 100 µg kg(-1) , the validation interval has been extended until 333 µg kg(-1) . The estimated performance characteristics were satisfactory complying with the requirements of Commission Decision 2002/657/EC. Good accuracies were obtained also taking advantage from the versatility of the hybrid mass analyser. Identification criteria were achieved verifying the mass accuracy and ion ratio of two ions, including the pseudomolecular one, where possible. Finally, the developed procedure was applied to 13 real cases of suspect milk samples (microbiological assay) confirming the presence of one or more antibiotics, although frequently, the maximum residue limits were not exceeded. The availability of rapid multiclass confirmatory methods can avoid wastes of suspect, but compliant, raw milk samples. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Extreme Temperature Operation of a 10 MHz Silicon Oscillator Type STCL1100
NASA Technical Reports Server (NTRS)
Patterson, Richard L.; Hammoud, Ahmad
2008-01-01
The performance of STMicroelectronics 10 MHz silicon oscillator was evaluated under exposure to extreme temperatures. The oscillator was characterized in terms of its output frequency stability, output signal rise and fall times, duty cycle, and supply current. The effects of thermal cycling and re-start capability at extreme low and high temperatures were also investigated. The silicon oscillator chip operated well with good stability in its output frequency over the temperature region of -50 C to +130 C, a range that by far exceeded its recommended specified boundaries of -20 C to +85 C. In addition, this chip, which is a low-cost oscillator designed for use in applications where great accuracy is not required, continued to function at cryogenic temperatures as low as - 195 C but at the expense of drop in its output frequency. The STCL1100 silicon oscillator was also able to re-start at both -195 C and +130 C, and it exhibited no change in performance due to the thermal cycling. In addition, no physical damage was observed in the packaging material due to extreme temperature exposure and thermal cycling. Therefore, it can be concluded that this device could potentially be used in space exploration missions under extreme temperature conditions in microprocessor and other applications where tight clock accuracy is not critical. In addition to the aforementioned screening evaluation, additional testing, however, is required to fully establish the reliability of these devices and to determine their suitability for long-term use.
21 CFR 184.1095 - Sulfuric acid.
Code of Federal Regulations, 2010 CFR
2010-04-01
... § 170.3(o)(23) of this chapter and processing aid as defined in § 170.3(o)(24) of this chapter. (d) The ingredient is used in food at levels not to exceed good manufacturing practice in accordance with § 184.1(b)(1). Current good manufacturing practice results in a maximum level, as served, of 0.014 percent for...
A new method of differential structural analysis of gamma-family basic parameters
NASA Technical Reports Server (NTRS)
Melkumian, L. G.; Ter-Antonian, S. V.; Smorodin, Y. A.
1985-01-01
The maximum likelihood method is used for the first time to restore parameters of electron photon cascades registered on X-ray films. The method permits one to carry out a structural analysis of the gamma quanta family darkening spots independent of the gamma quanta overlapping degree, and to obtain maximum admissible accuracies in estimating the energies of the gamma quanta composing a family. The parameter estimation accuracy weakly depends on the value of the parameters themselves and exceeds by an order of the values obtained by integral methods.
Interior radiances in optically deep absorbing media. I - Exact solutions for one-dimensional model.
NASA Technical Reports Server (NTRS)
Kattawar, G. W.; Plass, G. N.
1973-01-01
An exact analytic solution to the one-dimensional scattering problem with arbitrary single scattering albedo and arbitrary surface albedo is presented. Expressions are given for the emergent flux from a homogeneous layer, the internal flux within the layer, and the radiative heating. A comparison of these results with the values calculated from the matrix operator theory indicates an exceedingly high accuracy. A detailed study is made of the error in the matrix operator results and its dependence on the accuracy of the starting value.
Landenburger, L.; Lawrence, R.L.; Podruzny, S.; Schwartz, C.C.
2008-01-01
Moderate resolution satellite imagery traditionally has been thought to be inadequate for mapping vegetation at the species level. This has made comprehensive mapping of regional distributions of sensitive species, such as whitebark pine, either impractical or extremely time consuming. We sought to determine whether using a combination of moderate resolution satellite imagery (Landsat Enhanced Thematic Mapper Plus), extensive stand data collected by land management agencies for other purposes, and modern statistical classification techniques (boosted classification trees) could result in successful mapping of whitebark pine. Overall classification accuracies exceeded 90%, with similar individual class accuracies. Accuracies on a localized basis varied based on elevation. Accuracies also varied among administrative units, although we were not able to determine whether these differences related to inherent spatial variations or differences in the quality of available reference data.
Interpreting Airpower: American Observation of the Battle of Britain
2010-06-01
Davis, Spaatz and Air War, 42. 27 David R. Mets, Masters of Airpower: General Carl A. Spaatz, (California: Presidio Press, 1988), 110. 49 Dunkirk ...bombing did not exceed the accuracy of level deliveries. They discounted the Luftwaffe‟s successful dive bombing at Dunkirk since the British forces
Thailand national programme of the Earth Resources Technology Satellite
NASA Technical Reports Server (NTRS)
Sabhasri, S. (Principal Investigator)
1976-01-01
The author has identified the following significant results. The study on locating hill tribe villages from LANDSAT imagery was successful and exceeded the initial expectations. Results of the study on land use and forest mapping using Skylab data demonstrated the capability and feasibility of large scale mapping with high accuracy.
Improving Accuracy in Detecting Acoustic Onsets
ERIC Educational Resources Information Center
Duyck, Wouter; Anseel, Frederik; Szmalec, Arnaud; Mestdagh, Pascal; Tavernier, Antoine; Hartsuiker, Robert J.
2008-01-01
In current cognitive psychology, naming latencies are commonly measured by electronic voice keys that detect when sound exceeds a certain amplitude threshold. However, recent research (e.g., K. Rastle & M. H. Davis, 2002) has shown that these devices are particularly inaccurate in precisely detecting acoustic onsets. In this article, the authors…
Accuracy assessment of NLCD 2006 land cover and impervious surface
Wickham, James D.; Stehman, Stephen V.; Gass, Leila; Dewitz, Jon; Fry, Joyce A.; Wade, Timothy G.
2013-01-01
Release of NLCD 2006 provides the first wall-to-wall land-cover change database for the conterminous United States from Landsat Thematic Mapper (TM) data. Accuracy assessment of NLCD 2006 focused on four primary products: 2001 land cover, 2006 land cover, land-cover change between 2001 and 2006, and impervious surface change between 2001 and 2006. The accuracy assessment was conducted by selecting a stratified random sample of pixels with the reference classification interpreted from multi-temporal high resolution digital imagery. The NLCD Level II (16 classes) overall accuracies for the 2001 and 2006 land cover were 79% and 78%, respectively, with Level II user's accuracies exceeding 80% for water, high density urban, all upland forest classes, shrubland, and cropland for both dates. Level I (8 classes) accuracies were 85% for NLCD 2001 and 84% for NLCD 2006. The high overall and user's accuracies for the individual dates translated into high user's accuracies for the 2001–2006 change reporting themes water gain and loss, forest loss, urban gain, and the no-change reporting themes for water, urban, forest, and agriculture. The main factor limiting higher accuracies for the change reporting themes appeared to be difficulty in distinguishing the context of grass. We discuss the need for more research on land-cover change accuracy assessment.
21 CFR 582.6851 - Stearyl citrate.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Stearyl citrate. (a) Product. Stearyl citrate. (b) Tolerance. This substance is generally recognized as safe for use at a level not exceeding 0.15 percent in accordance with good manufacturing or feeding...
21 CFR 582.6386 - Isopropyl citrate.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Isopropyl citrate. (a) Product. Isopropyl citrate. (b) Tolerance. This substance is generally recognized as safe for use at a level not exceeding 0.02 percent in accordance with good manufacturing or feeding...
Evaluation of Cobas Integra 800 under simulated routine conditions in six laboratories.
Redondo, Francisco L; Bermudez, Pilar; Cocco, Claudio; Colella, Francesca; Graziani, Maria Stella; Fiehn, Walter; Hierla, Thomas; Lemoël, Gisèle; Belliard, AnneMarie; Manene, Dieudonne; Meziani, Mourad; Liebel, Maryann; McQueen, Matthew J; Stockmann, Wolfgang
2003-03-01
The new selective access analyser Cobas Integra 800 from Roche Diagnostics was evaluated in an international multicentre study at six sites. Routine simulation experiments showed good performance and full functionality of the instrument and provocation of anomalous situations generated no problems. The new features on Cobas Integra 800, namely clot detection and dispensing control, worked according to specifications. The imprecision of Cobas Integra 800 fulfilled the proposed quality specifications regarding imprecision of analytical systems for clinical chemistry with few exceptions. Claims for linearity, drift, and carry-over were all within the defined specifications, except urea linearity. Interference exists in some cases, as could be expected due to the chemistries applied. Accuracy met the proposed quality specifications, except in some special cases. Method comparisons with Cobas Integra 700 showed good agreement; comparisons with other analysis systems yielded in several cases explicable deviations. Practicability of Cobas Integra 800 met or exceeded the requirements for more than 95% of all attributes rated. The strong points of the new analysis system were reagent handling, long stability of calibration curves, high number of tests on board, compatibility of the sample carrier to other Roche systems, and the sample integrity check for more reliable analytical results. The improvement of the workflow offered by the 5-position rack and STAT handling like on Cobas Integra 800 makes the instrument attractive for further consolidation in the medium-sized laboratory, for dedicated use of special analytes, and/or as back-up in the large routine laboratory.
Khashan, Raed; Zheng, Weifan; Tropsha, Alexander
2014-03-01
We present a novel approach to generating fragment-based molecular descriptors. The molecules are represented by labeled undirected chemical graph. Fast Frequent Subgraph Mining (FFSM) is used to find chemical-fragments (subgraphs) that occur in at least a subset of all molecules in a dataset. The collection of frequent subgraphs (FSG) forms a dataset-specific descriptors whose values for each molecule are defined by the number of times each frequent fragment occurs in this molecule. We have employed the FSG descriptors to develop variable selection k Nearest Neighbor (kNN) QSAR models of several datasets with binary target property including Maximum Recommended Therapeutic Dose (MRTD), Salmonella Mutagenicity (Ames Genotoxicity), and P-Glycoprotein (PGP) data. Each dataset was divided into training, test, and validation sets to establish the statistical figures of merit reflecting the model validated predictive power. The classification accuracies of models for both training and test sets for all datasets exceeded 75 %, and the accuracy for the external validation sets exceeded 72 %. The model accuracies were comparable or better than those reported earlier in the literature for the same datasets. Furthermore, the use of fragment-based descriptors affords mechanistic interpretation of validated QSAR models in terms of essential chemical fragments responsible for the compounds' target property. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Calibration Of Airborne Visible/IR Imaging Spectrometer
NASA Technical Reports Server (NTRS)
Vane, G. A.; Chrien, T. G.; Miller, E. A.; Reimer, J. H.
1990-01-01
Paper describes laboratory spectral and radiometric calibration of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) applied to all AVIRIS science data collected in 1987. Describes instrumentation and procedures used and demonstrates that calibration accuracy achieved exceeds design requirements. Developed for use in remote-sensing studies in such disciplines as botany, geology, hydrology, and oceanography.
Analytical dose modeling for preclinical proton irradiation of millimetric targets.
Vanstalle, Marie; Constanzo, Julie; Karakaya, Yusuf; Finck, Christian; Rousseau, Marc; Brasse, David
2018-01-01
Due to the considerable development of proton radiotherapy, several proton platforms have emerged to irradiate small animals in order to study the biological effectiveness of proton radiation. A dedicated analytical treatment planning tool was developed in this study to accurately calculate the delivered dose given the specific constraints imposed by the small dimensions of the irradiated areas. The treatment planning system (TPS) developed in this study is based on an analytical formulation of the Bragg peak and uses experimental range values of protons. The method was validated after comparison with experimental data from the literature and then compared to Monte Carlo simulations conducted using Geant4. Three examples of treatment planning, performed with phantoms made of water targets and bone-slab insert, were generated with the analytical formulation and Geant4. Each treatment planning was evaluated using dose-volume histograms and gamma index maps. We demonstrate the value of the analytical function for mouse irradiation, which requires a targeting accuracy of 0.1 mm. Using the appropriate database, the analytical modeling limits the errors caused by misestimating the stopping power. For example, 99% of a 1-mm tumor irradiated with a 24-MeV beam receives the prescribed dose. The analytical dose deviations from the prescribed dose remain within the dose tolerances stated by report 62 of the International Commission on Radiation Units and Measurements for all tested configurations. In addition, the gamma index maps show that the highly constrained targeting accuracy of 0.1 mm for mouse irradiation leads to a significant disagreement between Geant4 and the reference. This simulated treatment planning is nevertheless compatible with a targeting accuracy exceeding 0.2 mm, corresponding to rat and rabbit irradiations. Good dose accuracy for millimetric tumors is achieved with the analytical calculation used in this work. These volume sizes are typical in mouse models for radiation studies. Our results demonstrate that the choice of analytical rather than simulated treatment planning depends on the animal model under consideration. © 2017 American Association of Physicists in Medicine.
Hahn, Tim; Kircher, Tilo; Straube, Benjamin; Wittchen, Hans-Ulrich; Konrad, Carsten; Ströhle, Andreas; Wittmann, André; Pfleiderer, Bettina; Reif, Andreas; Arolt, Volker; Lueken, Ulrike
2015-01-01
Although neuroimaging research has made substantial progress in identifying the large-scale neural substrate of anxiety disorders, its value for clinical application lags behind expectations. Machine-learning approaches have predictive potential for individual-patient prognostic purposes and might thus aid translational efforts in psychiatric research. To predict treatment response to cognitive behavioral therapy (CBT) on an individual-patient level based on functional magnetic resonance imaging data in patients with panic disorder with agoraphobia (PD/AG). We included 49 patients free of medication for at least 4 weeks and with a primary diagnosis of PD/AG in a longitudinal study performed at 8 clinical research institutes and outpatient centers across Germany. The functional magnetic resonance imaging study was conducted between July 2007 and March 2010. Twelve CBT sessions conducted 2 times a week focusing on behavioral exposure. Treatment response was defined as exceeding a 50% reduction in Hamilton Anxiety Rating Scale scores. Blood oxygenation level-dependent signal was measured during a differential fear-conditioning task. Regional and whole-brain gaussian process classifiers using a nested leave-one-out cross-validation were used to predict the treatment response from data acquired before CBT. Although no single brain region was predictive of treatment response, integrating regional classifiers based on data from the acquisition and the extinction phases of the fear-conditioning task for the whole brain yielded good predictive performance (accuracy, 82%; sensitivity, 92%; specificity, 72%; P < .001). Data from the acquisition phase enabled 73% correct individual-patient classifications (sensitivity, 80%; specificity, 67%; P < .001), whereas data from the extinction phase led to an accuracy of 74% (sensitivity, 64%; specificity, 83%; P < .001). Conservative reanalyses under consideration of potential confounders yielded nominally lower but comparable accuracy rates (acquisition phase, 70%; extinction phase, 71%; combined, 79%). Predicting treatment response to CBT based on functional neuroimaging data in PD/AG is possible with high accuracy on an individual-patient level. This novel machine-learning approach brings personalized medicine within reach, directly supporting clinical decisions for the selection of treatment options, thus helping to improve response rates.
Validation of Imaging With Pathology in Laryngeal Cancer: Accuracy of the Registration Methodology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Caldas-Magalhaes, Joana, E-mail: J.CaldasMagalhaes@umcutrecht.nl; Kasperts, Nicolien; Kooij, Nina
2012-02-01
Purpose: To investigate the feasibility and accuracy of an automated method to validate gross tumor volume (GTV) delineations with pathology in laryngeal and hypopharyngeal cancer. Methods and Materials: High-resolution computed tomography (CT{sub HR}), magnetic resonance imaging (MRI), and positron emission tomography (PET) scans were obtained from 10 patients before total laryngectomy. The GTV was delineated separately in each imaging modality. The laryngectomy specimen was sliced transversely in 3-mm-thick slices, and whole-mount hematoxylin-eosin stained (H and E) sections were obtained. A pathologist delineated tumor tissue in the H and E sections (GTV{sub PATH}). An automatic three-dimensional (3D) reconstruction of the specimenmore » was performed, and the CT{sub HR}, MRI, and PET were semiautomatically and rigidly registered to the 3D specimen. The accuracy of the pathology-imaging registration and the specimen deformation and shrinkage were assessed. The tumor delineation inaccuracies were compared with the registration errors. Results: Good agreement was observed between anatomical landmarks in the 3D specimen and in the in vivo images. Limited deformations and shrinkage (3% {+-} 1%) were found inside the cartilage skeleton. The root mean squared error of the registration between the 3D specimen and the CT, MRI, and PET was on average 1.5, 3.0, and 3.3 mm, respectively, in the cartilage skeleton. The GTV{sub PATH} volume was 7.2 mL, on average. The GTVs based on CT, MRI, and PET generated a mean volume of 14.9, 18.3, and 9.8 mL and covered the GTV{sub PATH} by 85%, 88%, and 77%, respectively. The tumor delineation inaccuracies exceeded the registration error in all the imaging modalities. Conclusions: Validation of GTV delineations with pathology is feasible with an average overall accuracy below 3.5 mm inside the laryngeal skeleton. The tumor delineation inaccuracies were larger than the registration error. Therefore, an accurate histological validation of anatomical and functional imaging techniques for GTV delineation is possible in laryngeal cancer patients.« less
21 CFR 172.884 - Odorless light petroleum hydrocarbons.
Code of Federal Regulations, 2014 CFR
2014-04-01
... in processing beet sugar and yeast Complying with § 173.340 of this chapter. As a float on... wild yeast contamination during fermentation In an amount not to exceed good manufacturing practice. In...
Story Goodness in Adolescents with Autism Spectrum Disorder (ASD) and in Optimal Outcomes from ASD
ERIC Educational Resources Information Center
Canfield, Allison R.; Eigsti, Inge-Marie; de Marchena, Ashley; Fein, Deborah
2016-01-01
Purpose: This study examined narrative quality of adolescents with autism spectrum disorder (ASD) using a well-studied "story goodness" coding system. Method: Narrative samples were analyzed for distinct aspects of story goodness and rated by naïve readers on dimensions of story goodness, accuracy, cohesiveness, and oddness. Adolescents…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, R.; Harrison, D. E. Jr.
A variable time step integration algorithm for carrying out molecular dynamics simulations of atomic collision cascades is proposed which evaluates the interaction forces only once per time step. The algorithm is tested on some model problems which have exact solutions and is compared against other common methods. These comparisons show that the method has good stability and accuracy. Applications to Ar/sup +/ bombardment of Cu and Si show good accuracy and improved speed to the original method (D. E. Harrison, W. L. Gay, and H. M. Effron, J. Math. Phys. /bold 10/, 1179 (1969)).
NASA Astrophysics Data System (ADS)
Gernez, Pierre; Stramski, Dariusz; Darecki, Miroslaw
2011-07-01
Time series measurements of fluctuations in underwater downward irradiance, Ed, within the green spectral band (532 nm) show that the probability distribution of instantaneous irradiance varies greatly as a function of depth within the near-surface ocean under sunny conditions. Because of intense light flashes caused by surface wave focusing, the near-surface probability distributions are highly skewed to the right and are heavy tailed. The coefficients of skewness and excess kurtosis at depths smaller than 1 m can exceed 3 and 20, respectively. We tested several probability models, such as lognormal, Gumbel, Fréchet, log-logistic, and Pareto, which are potentially suited to describe the highly skewed heavy-tailed distributions. We found that the models cannot approximate with consistently good accuracy the high irradiance values within the right tail of the experimental distribution where the probability of these values is less than 10%. This portion of the distribution corresponds approximately to light flashes with Ed > 1.5?, where ? is the time-averaged downward irradiance. However, the remaining part of the probability distribution covering all irradiance values smaller than the 90th percentile can be described with a reasonable accuracy (i.e., within 20%) with a lognormal model for all 86 measurements from the top 10 m of the ocean included in this analysis. As the intensity of irradiance fluctuations decreases with depth, the probability distribution tends toward a function symmetrical around the mean like the normal distribution. For the examined data set, the skewness and excess kurtosis assumed values very close to zero at a depth of about 10 m.
NASA Technical Reports Server (NTRS)
Lachenmayr, Georg
1992-01-01
IABG has been using various servohydraulic test facilities for many years for the reproduction of service loads and environmental loads on all kinds of test objects. For more than 15 years, a multi-axis vibration test facility has been under service, originally designed for earthquake simulation but being upgraded to the demands of space testing. First tests with the DFS/STM showed good reproduction accuracy and demonstrated the feasibility of transient vibration testing of space objects on a multi-axis hydraulic shaker. An approach to structural qualification is possible by using this test philosophy. It will be outlined and its obvious advantages over the state-of-the-art single-axis test will be demonstrated by example results. The new test technique has some special requirements to the test facility exceeding those of earthquake testing. Most important is the high reproduction accuracy demanded for a sophisticated control system. The state-of-the-art approach of analog closed-loop control circuits for each actuator combined with a static decoupling network and an off-line iterative waveform control is not able to meet all the demands. Therefore, the future over-all control system is implemented as hierarchical full digital closed-loop system on a highly parallel transputer network. The innermost layer is the digital actuator controller, the second one is the MDOF-control of the table movement. The outermost layer would be the off-line iterative waveform control, which is dedicated only to deal with the interaction of test table and test object or non-linear effects. The outline of the system will be presented.
Yamada, Hiroshi; Saeki, Minako; Ito, Junko; Kawada, Kazuhiro; Higurashi, Aya; Funakoshi, Hiromi; Takeda, Kohji
2015-02-01
The pulse CO-Oximeter (Radical-7; Masimo Corp., Irvine, CA) is a multi-wavelength spectrophotometric method for noninvasive continuous monitoring of hemoglobin (SpHb). Because evaluating the relative change in blood volume (ΔBV) is crucial to avoid hypovolemia and hypotension during hemodialysis, it would be of great clinical benefit if ΔBV could be estimated by measurement of SpHb during hemodialysis. The capability of the pulse CO-Oximeter to monitor ΔBV depends on the relative trending accuracy of SpHb. The purpose of the current study was to evaluate the relative trending accuracy of SpHb by the pulse CO-Oximeter using Crit-Line as a reference device. In 12 patients who received hemodialysis (total 22 sessions) in the intensive care unit, ΔBV was determined from SpHb. Relative changes in blood volume determined from SpHb were calculated according to the equation: ΔBV(SpHb)=[starting SpHb]/[current SpHb] - 1. The absolute values of SpHb and hematocrit measured by Crit-Line (CL-Hct) showed poor correlation. On the contrary, linear regression analysis showed good correlation between ΔBV(SpHb) and the relative change in blood volume measured by Crit-Line [ΔBV(CL-Hct)] (r=0.83; P≤0.001). Bland-Altman analysis also revealed good agreement between ΔBV(SpHb) and ΔBV(CL-Hct) (bias, -0.77%; precision, 3.41%). Polar plot analysis revealed good relative trending accuracy of SpHb with an angular bias of 4.1° and radial limits of agreement of 24.4° (upper) and -16.2° (lower). The results of the current study indicate that SpHb measurement with the pulse CO-Oximeter has good relative trending accuracy.
A general prediction model for the detection of ADHD and Autism using structural and functional MRI.
Sen, Bhaskar; Borle, Neil C; Greiner, Russell; Brown, Matthew R G
2018-01-01
This work presents a novel method for learning a model that can diagnose Attention Deficit Hyperactivity Disorder (ADHD), as well as Autism, using structural texture and functional connectivity features obtained from 3-dimensional structural magnetic resonance imaging (MRI) and 4-dimensional resting-state functional magnetic resonance imaging (fMRI) scans of subjects. We explore a series of three learners: (1) The LeFMS learner first extracts features from the structural MRI images using the texture-based filters produced by a sparse autoencoder. These filters are then convolved with the original MRI image using an unsupervised convolutional network. The resulting features are used as input to a linear support vector machine (SVM) classifier. (2) The LeFMF learner produces a diagnostic model by first computing spatial non-stationary independent components of the fMRI scans, which it uses to decompose each subject's fMRI scan into the time courses of these common spatial components. These features can then be used with a learner by themselves or in combination with other features to produce the model. Regardless of which approach is used, the final set of features are input to a linear support vector machine (SVM) classifier. (3) Finally, the overall LeFMSF learner uses the combined features obtained from the two feature extraction processes in (1) and (2) above as input to an SVM classifier, achieving an accuracy of 0.673 on the ADHD-200 holdout data and 0.643 on the ABIDE holdout data. Both of these results, obtained with the same LeFMSF framework, are the best known, over all hold-out accuracies on these datasets when only using imaging data-exceeding previously-published results by 0.012 for ADHD and 0.042 for Autism. Our results show that combining multi-modal features can yield good classification accuracy for diagnosis of ADHD and Autism, which is an important step towards computer-aided diagnosis of these psychiatric diseases and perhaps others as well.
Weber, Marc; Teeling, Hanno; Huang, Sixing; Waldmann, Jost; Kassabgy, Mariette; Fuchs, Bernhard M; Klindworth, Anna; Klockow, Christine; Wichels, Antje; Gerdts, Gunnar; Amann, Rudolf; Glöckner, Frank Oliver
2011-05-01
Next-generation sequencing (NGS) technologies have enabled the application of broad-scale sequencing in microbial biodiversity and metagenome studies. Biodiversity is usually targeted by classifying 16S ribosomal RNA genes, while metagenomic approaches target metabolic genes. However, both approaches remain isolated, as long as the taxonomic and functional information cannot be interrelated. Techniques like self-organizing maps (SOMs) have been applied to cluster metagenomes into taxon-specific bins in order to link biodiversity with functions, but have not been applied to broad-scale NGS-based metagenomics yet. Here, we provide a novel implementation, demonstrate its potential and practicability, and provide a web-based service for public usage. Evaluation with published data sets mimicking varyingly complex habitats resulted into classification specificities and sensitivities of close to 100% to above 90% from phylum to genus level for assemblies exceeding 8 kb for low and medium complexity data. When applied to five real-world metagenomes of medium complexity from direct pyrosequencing of marine subsurface waters, classifications of assemblies above 2.5 kb were in good agreement with fluorescence in situ hybridizations, indicating that biodiversity was mostly retained within the metagenomes, and confirming high classification specificities. This was validated by two protein-based classifications (PBCs) methods. SOMs were able to retrieve the relevant taxa down to the genus level, while surpassing PBCs in resolution. In order to make the approach accessible to a broad audience, we implemented a feature-rich web-based SOM application named TaxSOM, which is freely available at http://www.megx.net/toolbox/taxsom. TaxSOM can classify reads or assemblies exceeding 2.5 kb with high accuracy and thus assists in linking biodiversity and functions in metagenome studies, which is a precondition to study microbial ecology in a holistic fashion.
NASA Astrophysics Data System (ADS)
Zarola, Amit; Sil, Arjun
2018-04-01
This study presents the forecasting of time and magnitude size of the next earthquake in the northeast India, using four probability distribution models (Gamma, Lognormal, Weibull and Log-logistic) considering updated earthquake catalog of magnitude Mw ≥ 6.0 that occurred from year 1737-2015 in the study area. On the basis of past seismicity of the region, two types of conditional probabilities have been estimated using their best fit model and respective model parameters. The first conditional probability is the probability of seismic energy (e × 1020 ergs), which is expected to release in the future earthquake, exceeding a certain level of seismic energy (E × 1020 ergs). And the second conditional probability is the probability of seismic energy (a × 1020 ergs/year), which is expected to release per year, exceeding a certain level of seismic energy per year (A × 1020 ergs/year). The logarithm likelihood functions (ln L) were also estimated for all four probability distribution models. A higher value of ln L suggests a better model and a lower value shows a worse model. The time of the future earthquake is forecasted by dividing the total seismic energy expected to release in the future earthquake with the total seismic energy expected to release per year. The epicentre of recently occurred 4 January 2016 Manipur earthquake (M 6.7), 13 April 2016 Myanmar earthquake (M 6.9) and the 24 August 2016 Myanmar earthquake (M 6.8) are located in zone Z.12, zone Z.16 and zone Z.15, respectively and that are the identified seismic source zones in the study area which show that the proposed techniques and models yield good forecasting accuracy.
Relationship between surface and free tropospheric ozone in the Western U.S.
Jaffe, Dan
2011-01-15
Ozone is an important air pollutant that affects lung function. In the U.S., the EPA has reduced the allowable O(3) concentrations several times over the last few decades. This puts greater emphasis on understanding the interannual variability and the contributions to surface O(3) from all sources. We have examined O(3) data from 11 rural CASTNET sites in the western US for the period 1995-2009. The 11 surface sites show a similar seasonal cycle and generally a good correlation in the deseasonalized monthly means, indicating that there are large scale influences on O(3) that operate across the entire western US. These sites also show a good correlation between site elevation and annual mean O(3), indicating a significant contribution from the free troposphere. We examined the number of exceedance days for each site, defined as a day when the Maximum Daily 8-h Average (MDA8) exceeds a threshold value. Over this time period, more than half of these sites exceeded an MDA8 threshold of 70 ppbv at least 4 times per year, and all sites exceeded a threshold value of 65 ppbv at least 4 times per year. The transition to lower threshold values increases substantially the number of exceedance days, especially during spring, reflecting the fact that background O(3) peaks during spring. We next examined the correlation between surface O(3) and free tropospheric O(3) in the same region, as measured by routine balloon launches from Boulder, CO. Using ozone measured by the balloon sensor in the range of 3-6 km above sea level we find statistically significant correlations between surface and free tropospheric O(3) in spring and summer months using both monthly means, daily MDA8 values, and the number of surface exceedance days. We suggest that during spring this correlation reflects variations in the flux of O(3) transport from the free troposphere to the surface. In summer, free tropospheric and surface concentrations of O(3) and the number of exceedance days are all significantly correlated with emissions from biomass burning in the western US. This indicates that wildfires significantly increase the number of exceedance days across the western U.S.
The Role of Pattern Goodness in the Reproduction of Backward Masked Patterns
ERIC Educational Resources Information Center
Bell, Herbert H.; Handel, Stephen
1976-01-01
The purpose of the present work was to investigate the relation between pattern goodness and accuracy of reproduction in backward masking. It may be hypothesized that good patterns, being easier to encode as wholes, will be reproduced more easily than poorer patterns. Four experiments were performed. (Author)
40 CFR 90.314 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2010 CFR
2010-07-01
... zero and calibration or span gases over any 10-second period must not exceed two percent of full-scale chart deflection on all ranges used. (3) Zero drift. The analyzer zero-response drift during a one-hour period must be less than two percent of full-scale chart deflection on the lowest range used. The zero...
An Inexpensive, Very High Impedance Digital Voltmeter for Selective Electrodes.
ERIC Educational Resources Information Center
Caceci, Marco S.
1984-01-01
Describes a compact, digital voltmeter which exceeds, both in accuracy and input impedance, most commercial pH meters and potentiometers. The instrument consists of two parts: a very high impedance hybrid operational amplifier used as a voltage follower (ICH8500/A, Intersil) and a four and one-half digits LED display panel meter (RP-4500,…
NASA Astrophysics Data System (ADS)
Waltham, Nathan J.; Sheaves, Marcus
2017-09-01
Understanding acute hyperthermic exposure risk to animals, including fish in tropical estuaries, is increasingly necessary under future climate change. To examine this hypothesis, fish (upper water column species - glassfish, Ambassis vachellii; river mullet, Chelon subviridis; diamond scale mullet, Ellochelon vaigiensis; and ponyfish, Leiognathus equulus; and lower water bottom dwelling species - whiting Sillago analis) were caught in an artificial tidal lake in tropical north Queensland (Australia), and transported to a laboratory tank to acclimate (3wks). After acclimation, fish (between 10 and 17 individuals each time) were transferred to a temperature ramping experimental tank, where a thermoline increased (2.5 °C/hr; which is the average summer water temperature increasing rate measured in the urban lakes) tank water temperature to establish threshold points where each fish species lost equilibrium (defined here as Acute Effect Temperature; AET). The coolest AET among all species was 33.1 °C (S. analis), while the highest was 39.9 °C (A. vachellii). High frequency loggers were deployed (November and March representing Austral summer) in the same urban lake where fish were sourced, to measure continuous (20min) surface (0.15 m) and bottom (0.1 m) temperature to derive thermal frequency curves to examine how often lake temperatures exceed AET thresholds. For most fish species examined, water temperature that could be lethal were exceeded at the surface, but rarely, if ever, at the bottom waters suggesting deep, cooler, water provides thermal refugia for fish. An energy-balance model was used to estimate daily mean lake water temperature with good accuracy (±1 °C; R2 = 0.91, modelled vs lake measured temperature). The model was used to predict climate change effects on lake water temperature, and the exceedance of thermal threshold change. A 2.3 °C climate warming (based on 2100 local climate prediction) raised lake water temperature by 1.3 °C. However, small as this increase might seem, it led to a doubling of time that water temperatures were in excess of AET thresholds at the surface, but also the bottom waters that presently provide thermal refugia for fish.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sokolov, V I; Glebov, V N; Malyutin, A M
2015-09-30
A method based on resonant excitation of waveguide modes with a prism coupler is proposed for measuring the thickness and refractive index of thin-film layers in multilayer dielectric structures. The peculiarities of reflection of TE- and TM-polarised light beams from a structure comprising eleven alternating layers of zinc sulfide (ZnS) and magnesium barium fluoride (MgBaF{sub 4}), whose thicknesses are much less than the wavelength of light, are investigated. Using the mathematical model developed, we have calculated the coefficients of reflection of collimated TE and TM light beams from a multilayer structure and determined the optical constants and thicknesses of themore » structure layers. The refractive indices of the layers, obtained for TE and TM polarisation of incident light, are in good agreement. The thicknesses of ZnS and MgBaF{sub 4} layers, found for different polarisations, coincide with an accuracy of ±1%. Thus, we have demonstrated for the first time that the prism-coupling technique allows one to determine the optical properties of thin-film structures when the number of layers in the structure exceeds ten layers. (integrated optics)« less
Petrovskii, Sergei; Petrovskaya, Natalia; Bearup, Daniel
2014-09-01
Pest insects pose a significant threat to food production worldwide resulting in annual losses worth hundreds of billions of dollars. Pest control attempts to prevent pest outbreaks that could otherwise destroy a sward. It is good practice in integrated pest management to recommend control actions (usually pesticides application) only when the pest density exceeds a certain threshold. Accurate estimation of pest population density in ecosystems, especially in agro-ecosystems, is therefore very important, and this is the overall goal of the pest insect monitoring. However, this is a complex and challenging task; providing accurate information about pest abundance is hardly possible without taking into account the complexity of ecosystems' dynamics, in particular, the existence of multiple scales. In the case of pest insects, monitoring has three different spatial scales, each of them having their own scale-specific goal and their own approaches to data collection and interpretation. In this paper, we review recent progress in mathematical models and methods applied at each of these scales and show how it helps to improve the accuracy and robustness of pest population density estimation. Copyright © 2014 Elsevier B.V. All rights reserved.
Kotchenova, Svetlana Y; Vermote, Eric F
2007-07-10
This is the second part of the validation effort of the recently developed vector version of the 6S (Second Simulation of a Satellite Signal in the Solar Spectrum) radiative transfer code (6SV1), primarily used for the calculation of look-up tables in the Moderate Resolution Imaging Spectroradiometer (MODIS) atmospheric correction algorithm. The 6SV1 code was tested against a Monte Carlo code and Coulson's tabulated values for molecular and aerosol atmospheres bounded by different Lambertian and anisotropic surfaces. The code was also tested in scalar mode against the scalar code SHARM to resolve the previous 6S accuracy issues in the case of an anisotropic surface. All test cases were characterized by good agreement between the 6SV1 and the other codes: The overall relative error did not exceed 0.8%. The study also showed that ignoring the effects of radiation polarization in the atmosphere led to large errors in the simulated top-of-atmosphere reflectances: The maximum observed error was approximately 7.2% for both Lambertian and anisotropic surfaces.
NASA Astrophysics Data System (ADS)
Kotchenova, Svetlana Y.; Vermote, Eric F.
2007-07-01
This is the second part of the validation effort of the recently developed vector version of the 6S (Second Simulation of a Satellite Signal in the Solar Spectrum) radiative transfer code (6SV1), primarily used for the calculation of look-up tables in the Moderate Resolution Imaging Spectroradiometer (MODIS) atmospheric correction algorithm. The 6SV1 code was tested against a Monte Carlo code and Coulson's tabulated values for molecular and aerosol atmospheres bounded by different Lambertian and anisotropic surfaces. The code was also tested in scalar mode against the scalar code SHARM to resolve the previous 6S accuracy issues in the case of an anisotropic surface. All test cases were characterized by good agreement between the 6SV1 and the other codes: The overall relative error did not exceed 0.8%. The study also showed that ignoring the effects of radiation polarization in the atmosphere led to large errors in the simulated top-of-atmosphere reflectances: The maximum observed error was approximately 7.2% for both Lambertian and anisotropic surfaces.
Eisenberg, Sarita; Guo, Ling-Yu
2016-05-01
This article reviews the existing literature on the diagnostic accuracy of two grammatical accuracy measures for differentiating children with and without language impairment (LI) at preschool and early school age based on language samples. The first measure, the finite verb morphology composite (FVMC), is a narrow grammatical measure that computes children's overall accuracy of four verb tense morphemes. The second measure, percent grammatical utterances (PGU), is a broader grammatical measure that computes children's accuracy in producing grammatical utterances. The extant studies show that FVMC demonstrates acceptable (i.e., 80 to 89% accurate) to good (i.e., 90% accurate or higher) diagnostic accuracy for children between 4;0 (years;months) and 6;11 in conversational or narrative samples. In contrast, PGU yields acceptable to good diagnostic accuracy for children between 3;0 and 8;11 regardless of sample types. Given the diagnostic accuracy shown in the literature, we suggest that FVMC and PGU can be used as one piece of evidence for identifying children with LI in assessment when appropriate. However, FVMC or PGU should not be used as therapy goals directly. Instead, when children are low in FVMC or PGU, we suggest that follow-up analyses should be conducted to determine the verb tense morphemes or grammatical structures that children have difficulty with. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Earth-orbiting extreme ultraviolet spectroscopic mission: SPRINT-A/EXCEED
NASA Astrophysics Data System (ADS)
Yoshikawa, I.; Tsuchiya, F.; Yamazaki, A.; Yoshioka, K.; Uemizu, K.; Murakami, G.; Kimura, T.; Kagitani, M.; Terada, N.; Kasaba, Y.; Sakanoi, T.; Ishii, H.; Uji, K.
2012-09-01
The EXCEED (Extreme Ultraviolet Spectroscope for Exospheric Dynamics) mission is an Earth-orbiting extreme ultraviolet (EUV) spectroscopic mission and the first in the SPRINT series being developed by ISAS/JAXA. It will be launched in the summer of 2013. EUV spectroscopy is suitable for observing tenuous gases and plasmas around planets in the solar system (e.g., Mercury, Venus, Mars, Jupiter, and Saturn). Advantage of remote sensing observation is to take a direct picture of the plasma dynamics and distinguish between spatial and temporal variability explicitly. One of the primary observation targets is an inner magnetosphere of Jupiter, whose plasma dynamics is dominated by planetary rotation. Previous observations have shown a few percents of the hot electron population in the inner magnetosphere whose temperature is 100 times higher than the background thermal electrons. Though the hot electrons have a significant impact on the energy balance in the inner magnetosphere, their generation process has not yet been elucidated. In the EUV range, a number of emission lines originate from plasmas distributed in Jupiter's inner magnetosphere. The EXCEED spectrograph is designed to have a wavelength range of 55-145 nm with minimum spectral resolution of 0.4 nm, enabling the electron temperature and ion composition in the inner magnetosphere to be determined. Another primary objective is to investigate an unresolved problem concerning the escape of the atmosphere to space. Although there have been some in-situ observations by orbiters, our knowledge is still limited. The EXCEED mission plans to make imaging observations of plasmas around Venus and Mars to determine the amounts of escaping atmosphere. The instrument's field of view (FOV) is so wide that we can get an image from the interaction region between the solar wind and planetary plasmas down to the tail region at one time. This will provide us with information about outward-flowing plasmas, e.g., their composition, rate, and dependence on solar activity. EXCEED has two mission instruments: the EUV spectrograph and a target guide camera that is sensitive to visible light. The EUV spectrograph is designed to have a wavelength range of 55-145 nm with a spectral resolution of 0.4-1.0 nm. The spectrograph slits have a FOV of 400 x 140 arcseconds (maximum). The optics of the instrument consists of a primary mirror with a diameter of 20cm, a laminar type grating, and a 5-stage micro-channel plate assembly with a resistive anode encoder. To achieve high efficiencies, the surfaces of the primary mirror and the grating are coated with CVD-SiC. Because of the large primary mirror and high efficiencies, good temporal resolution and complete spatial coverage for Io plasma torus observation is expected. Based on a feasibility study using the spectral diagnosis method, it is shown that EXCEED can determine the Io plasma torus parameters, such as the electron density, temperatures, hot electron fraction and so on, using an exposure time of 50 minutes. The target guide camera will be used to capture the target and guide the observation area of interest to the slit. Emissions from outside the slit's FOV will be reflected by the front of the slit and guided to the target guide camera. The guide camera's FOV is 240" x 240". The camera will take an image every 3 seconds and the image is sent to a mission data processor (MDP), which calculates the centroid of the image. During an observation, the bus system controls the attitude to keep the centroid position of the target in the guide camera with an accuracy of ±5 arc-seconds. With the help of the target guide camera, we will take spectral images with a long exposure time of 50 minutes and good spatial resolution of 20 arc-seconds.
Buczinski, S; Vandeweerd, J M
2016-09-01
Provision of good quality colostrum [i.e., immunoglobulin G (IgG) concentration ≥50g/L] is the first step toward ensuring proper passive transfer of immunity for young calves. Precise quantification of colostrum IgG levels cannot be easily performed on the farm. Assessment of the refractive index using a Brix scale with a refractometer has been described as being highly correlated with IgG concentration in colostrum. The aim of this study was to perform a systematic review of the diagnostic accuracy of Brix refractometry to diagnose good quality colostrum. From 101 references initially obtain ed, 11 were included in the systematic review meta-analysis representing 4,251 colostrum samples. The prevalence of good colostrum samples with IgG ≥50g/L varied from 67.3 to 92.3% (median 77.9%). Specific estimates of accuracy [sensitivity (Se) and specificity (Sp)] were obtained for different reported cut-points using a hierarchical summary receiver operating characteristic curve model. For the cut-point of 22% (n=8 studies), Se=80.2% (95% CI: 71.1-87.0%) and Sp=82.6% (71.4-90.0%). Decreasing the cut-point to 18% increased Se [96.1% (91.8-98.2%)] and decreased Sp [54.5% (26.9-79.6%)]. Modeling the effect of these Brix accuracy estimates using a stochastic simulation and Bayes theorem showed that a positive result with the 22% Brix cut-point can be used to diagnose good quality colostrum (posttest probability of a good colostrum: 94.3% (90.7-96.9%). The posttest probability of good colostrum with a Brix value <18% was only 22.7% (12.3-39.2%). Based on this study, the 2 cut-points could be alternatively used to select good quality colostrum (sample with Brix ≥22%) or to discard poor quality colostrum (sample with Brix <18%). When sample results are between these 2 values, colostrum supplementation should be considered. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Cosmic Origins Spectrograph: On-Orbit Performance of Target Acquisitions
NASA Astrophysics Data System (ADS)
Penton, Steven V.
2010-07-01
COS is a slit-less spectrograph with a very small aperture (R=1.2500). To achieve the desired wavelength accuracies, HST+COS must center the target to within 0.100 of the center of the aperture for the FUV channel, and 0.0400 for NUV. During SMOV and early Cycle 17 we fine-tuned the COS target acquisition (TA) procedures to exceed this accuracy for all three COS TA modes; NUV imaging, NUV spectroscopic, and FUV spectroscopic. In Cycle 17, we also adjusted the COSto- FGS offsets in the SIAF file. This allows us to recommend skipping the time consuming ACQ/SEARCH in cases where the target coordinates are well known. Here we will compare the on-orbit performance of all COS TA modes in terms of centering accuracy, efficiency, and required signal-to-noise (S/N).
21 CFR 172.381 - Vitamin D2 bakers yeast.
Code of Federal Regulations, 2014 CFR
2014-04-01
... conventional bakers yeast. (c) The additive may be used in yeast-leavened baked goods and baking mixes and yeast-leavened baked snack foods at levels not to exceed 400 International Units of vitamin D2 per 100...
Brain-Computer Interface Based on Generation of Visual Images
Bobrov, Pavel; Frolov, Alexander; Cantor, Charles; Fedulova, Irina; Bakhnyan, Mikhail; Zhavoronkov, Alexander
2011-01-01
This paper examines the task of recognizing EEG patterns that correspond to performing three mental tasks: relaxation and imagining of two types of pictures: faces and houses. The experiments were performed using two EEG headsets: BrainProducts ActiCap and Emotiv EPOC. The Emotiv headset becomes widely used in consumer BCI application allowing for conducting large-scale EEG experiments in the future. Since classification accuracy significantly exceeded the level of random classification during the first three days of the experiment with EPOC headset, a control experiment was performed on the fourth day using ActiCap. The control experiment has shown that utilization of high-quality research equipment can enhance classification accuracy (up to 68% in some subjects) and that the accuracy is independent of the presence of EEG artifacts related to blinking and eye movement. This study also shows that computationally-inexpensive Bayesian classifier based on covariance matrix analysis yields similar classification accuracy in this problem as a more sophisticated Multi-class Common Spatial Patterns (MCSP) classifier. PMID:21695206
Improving crop classification through attention to the timing of airborne radar acquisitions
NASA Technical Reports Server (NTRS)
Brisco, B.; Ulaby, F. T.; Protz, R.
1984-01-01
Radar remote sensors may provide valuable input to crop classification procedures because of (1) their independence of weather conditions and solar illumination, and (2) their ability to respond to differences in crop type. Manual classification of multidate synthetic aperture radar (SAR) imagery resulted in an overall accuracy of 83 percent for corn, forest, grain, and 'other' cover types. Forests and corn fields were identified with accuracies approaching or exceeding 90 percent. Grain fields and 'other' fields were often confused with each other, resulting in classification accuracies of 51 and 66 percent, respectively. The 83 percent correct classification represents a 10 percent improvement when compared to similar SAR data for the same area collected at alternate time periods in 1978. These results demonstrate that improvements in crop classification accuracy can be achieved with SAR data by synchronizing data collection times with crop growth stages in order to maximize differences in the geometric and dielectric properties of the cover types of interest.
High Accuracy Monocular SFM and Scale Correction for Autonomous Driving.
Song, Shiyu; Chandraker, Manmohan; Guest, Clark C
2016-04-01
We present a real-time monocular visual odometry system that achieves high accuracy in real-world autonomous driving applications. First, we demonstrate robust monocular SFM that exploits multithreading to handle driving scenes with large motions and rapidly changing imagery. To correct for scale drift, we use known height of the camera from the ground plane. Our second contribution is a novel data-driven mechanism for cue combination that allows highly accurate ground plane estimation by adapting observation covariances of multiple cues, such as sparse feature matching and dense inter-frame stereo, based on their relative confidences inferred from visual data on a per-frame basis. Finally, we demonstrate extensive benchmark performance and comparisons on the challenging KITTI dataset, achieving accuracy comparable to stereo and exceeding prior monocular systems. Our SFM system is optimized to output pose within 50 ms in the worst case, while average case operation is over 30 fps. Our framework also significantly boosts the accuracy of applications like object localization that rely on the ground plane.
Torralbo, Ana; Walther, Dirk B.; Chai, Barry; Caddigan, Eamon; Fei-Fei, Li; Beck, Diane M.
2013-01-01
Within the range of images that we might categorize as a “beach”, for example, some will be more representative of that category than others. Here we first confirmed that humans could categorize “good” exemplars better than “bad” exemplars of six scene categories and then explored whether brain regions previously implicated in natural scene categorization showed a similar sensitivity to how well an image exemplifies a category. In a behavioral experiment participants were more accurate and faster at categorizing good than bad exemplars of natural scenes. In an fMRI experiment participants passively viewed blocks of good or bad exemplars from the same six categories. A multi-voxel pattern classifier trained to discriminate among category blocks showed higher decoding accuracy for good than bad exemplars in the PPA, RSC and V1. This difference in decoding accuracy cannot be explained by differences in overall BOLD signal, as average BOLD activity was either equivalent or higher for bad than good scenes in these areas. These results provide further evidence that V1, RSC and the PPA not only contain information relevant for natural scene categorization, but their activity patterns mirror the fundamentally graded nature of human categories. Analysis of the image statistics of our good and bad exemplars shows that variability in low-level features and image structure is higher among bad than good exemplars. A simulation of our neuroimaging experiment suggests that such a difference in variance could account for the observed differences in decoding accuracy. These results are consistent with both low-level models of scene categorization and models that build categories around a prototype. PMID:23555588
Kang, Seung-Gul; Kang, Jae Myeong; Ko, Kwang-Pil; Park, Seon-Cheol; Mariani, Sara; Weng, Jia
2017-06-01
To compare the accuracy of the commercial Fitbit Flex device (FF) with polysomnography (PSG; the gold-standard method) in insomnia disorder patients and good sleepers. Participants wore an FF and actigraph while undergoing overnight PSG. Primary outcomes were intraclass correlation coefficients (ICCs) of the total sleep time (TST) and sleep efficiency (SE), and the frequency of clinically acceptable agreement between the FF in normal mode (FFN) and PSG. The sensitivity, specificity, and accuracy of detecting sleep epochs were compared among FFN, actigraphy, and PSG. The ICCs of the TST between FFN and PSG in the insomnia (ICC=0.886) and good-sleepers (ICC=0.974) groups were excellent, but the ICC of SE was only fair in both groups. The TST and SE were overestimated for FFN by 6.5min and 1.75%, respectively, in good sleepers, and by 32.9min and 7.9% in the insomnia group with respect to PSG. The frequency of acceptable agreement of FFN and PSG was significantly lower (p=0.006) for the insomnia group (39.4%) than for the good-sleepers group (82.4%). The sensitivity and accuracy of FFN in an epoch-by-epoch comparison with PSG was good and comparable to those of actigraphy, but the specificity was poor in both groups. The ICC of TST in the FFN-PSG comparison was excellent in both groups, and the frequency of agreement was high in good sleepers but significantly lower in insomnia patients. These limitations need to be considered when applying commercial sleep trackers for clinical and research purposes in insomnia. Copyright © 2017 Elsevier Inc. All rights reserved.
Spatial and thematic assessment of object-based forest stand delineation using an OFA-matrix
NASA Astrophysics Data System (ADS)
Hernando, A.; Tiede, D.; Albrecht, F.; Lang, S.
2012-10-01
The delineation and classification of forest stands is a crucial aspect of forest management. Object-based image analysis (OBIA) can be used to produce detailed maps of forest stands from either orthophotos or very high resolution satellite imagery. However, measures are then required for evaluating and quantifying both the spatial and thematic accuracy of the OBIA output. In this paper we present an approach for delineating forest stands and a new Object Fate Analysis (OFA) matrix for accuracy assessment. A two-level object-based orthophoto analysis was first carried out to delineate stands on the Dehesa Boyal public land in central Spain (Avila Province). Two structural features were first created for use in class modelling, enabling good differentiation between stands: a relational tree cover cluster feature, and an arithmetic ratio shadow/tree feature. We then extended the OFA comparison approach with an OFA-matrix to enable concurrent validation of thematic and spatial accuracies. Its diagonal shows the proportion of spatial and thematic coincidence between a reference data and the corresponding classification. New parameters for Spatial Thematic Loyalty (STL), Spatial Thematic Loyalty Overall (STLOVERALL) and Maximal Interfering Object (MIO) are introduced to summarise the OFA-matrix accuracy assessment. A stands map generated by OBIA (classification data) was compared with a map of the same area produced from photo interpretation and field data (reference data). In our example the OFA-matrix results indicate good spatial and thematic accuracies (>65%) for all stand classes except for the shrub stands (31.8%), and a good STLOVERALL (69.8%). The OFA-matrix has therefore been shown to be a valid tool for OBIA accuracy assessment.
Can artificial neural networks be used to predict the origin of ozone episodes?
Fontes, T; Silva, L M; Silva, M P; Barros, N; Carvalho, A C
2014-08-01
Tropospheric ozone is a secondary pollutant having a negative impact on health and environment. To control and minimize such impact the European Community established regulations to promote a clean air all over Europe. However, when an episode is related with natural mechanisms as Stratosphere-Troposphere Exchanges (STE), the benefits of an action plan to minimize precursor emissions are inefficient. Therefore, this work aims to develop a tool to identify the sources of ozone episodes in order to minimize misclassification and thus avoid the implementation of inappropriate air quality plans. For this purpose, an artificial neural network model - the Multilayer Perceptron - is used as a binary classifier of the source of an ozone episode. Long data series, between 2001 and 2010, considering the ozone precursors, (7)Be activity and meteorological conditions were used. With this model, 2-7% of a mean error was achieved, which is considered as a good generalization. Accuracy measures for imbalanced data are also discussed. The MCC values show a good performance of the model (0.65-0.92). Precision and F1-measure indicate that the model specifies a little better the rare class. Thus, the results demonstrate that such a tool can be used to help authorities in the management of ozone, namely when its thresholds are exceeded due natural causes, as the above mentioned STE. Therefore, the resources used to implement an action plan to minimize ozone precursors could be better managed avoiding the implementation of inappropriate measures. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Suryawanshi, Vishwas D.; Gore, Anil H.; Dongare, Pravin R.; Anbhule, Prashant V.; Patil, Shivajirao R.; Kolekar, Govind B.
2013-10-01
An efficient fluorescent chemosensor Al3+ receptor based on pyrimidine derivative,2-amino-6-hydroxy-4-(4-N,N-dimethylaminophenyl)-pyrimidine-5-carbonitrile (DMAB), has been synthesized by three-component condensation of aromatic aldehyde, ethyl cyanoacetate and guanidine hydrochloride in ethanol under alkaline medium. High selectivity and sensitivity of DMAB towards Aluminum ion (Al3+) in water: ethanol and acetate buffer at pH 4.0 makes it suitable to detect Al3+ with steady-state UV-vis and fluorescence spectroscopy. Method shows good selectivity towards Al3+ over other coexisting metal ions tested, viz. Fe2+, Ni2+, Cu2+, Co2+, Pb2+, Sb3+, Na+, Ca2+, Mg2+, Zn2+, Hg2+, Ba2+, Cd2+ and K+. A good linearity between the Stern-Volmer plots of F0/F versus concentration of Al3+ was observed over the range from 10 to 60 μg mL-1 with correlation coefficient of 0.991. The accuracy and reliability of the method were further confirmed by recovery studies via standard addition method with percent recoveries in the range of 101.03-103.44% and lowest detection limit (LOD = 7.35 μg mL-1) for Al3+ was established. This method may offer a new cost-effective, rapid, and simple key to the inspection of Al3+ ions in water samples in the presence of a complex matrix and can be capable of evaluating the exceeding standard of Al3+ in environmental water samples. The probable mechanism for fluorescence quenching was also discussed.
Hwang, Seonhong; Tsai, Chung-Ying; Koontz, Alicia M
2017-05-24
The purpose of this study was to test the concurrent validity and test-retest reliability of the Kinect skeleton tracking algorithm for measurement of trunk, shoulder, and elbow joint angle measurement during a wheelchair transfer task. Eight wheelchair users were recruited for this study. Joint positions were recorded simultaneously by the Kinect and Vicon motion capture systems while subjects transferred from their wheelchairs to a level bench. Shoulder, elbow, and trunk angles recorded with the Kinect system followed a similar trajectory as the angles recorded with the Vicon system with correlation coefficients that are larger than 0.71 on both sides (leading arm and trailing arm). The root mean square errors (RMSEs) ranged from 5.18 to 22.46 for the shoulder, elbow, and trunk angles. The 95% limits of agreement (LOA) for the discrepancy between the two systems exceeded the clinical significant level of 5°. For the trunk, shoulder, and elbow angles, the Kinect had very good relative reliability for the measurement of sagittal, frontal and horizontal trunk angles, as indicated by the high intraclass correlation coefficient (ICC) values (>0.90). Small standard error of the measure (SEM) values, indicating good absolute reliability, were observed for all joints except for the leading arm's shoulder joint. Relatively large minimal detectable changes (MDCs) were observed in all joint angles. The Kinect motion tracking has promising performance levels for some upper limb joints. However, more accurate measurement of the joint angles may be required. Therefore, understanding the limitations in precision and accuracy of Kinect is imperative before utilization of Kinect.
2012-01-01
This study represents the first report on the development of a novel spectrophotometric method for determination of cinacalcet hydrochloride (CIN) in its tablet dosage forms. Studies were carried out to investigate the reaction between CIN and 1,2-naphthoquinone-4-sulphonate (NQS) reagent. In alkaline medium (pH 8.5), an orange red-colored product exhibiting maximum absorption peak (λmax) at 490 nm was produced. The stoichiometry and kinetic of the reaction were investigated and the reaction mechanism was postulated. This color-developing reaction was employed in the development of a simple and rapid visible-spectrophotometric method for determination of CIN in its tablets. Under the optimized reaction conditions, Beer's law correlating the absorbance with CIN concentration was obeyed in the range of 3 - 100 μg/ml with good correlation coefficient (0.9993). The molar absorptivity (ε) was 4.2 × 105 l/mol/cm. The limits of detection and quantification were 1.9 and 5.7 μg/ml, respectively. The precision of the method was satisfactory; the values of relative standard deviations (RSD) did not exceed 2%. No interference was observed from the excipients that are present in the tablets. The proposed method was applied successfully for the determination of CIN in its pharmaceutical tablets with good accuracy and precisions; the label claim percentage was 100.80 - 102.23 ± 1.27 - 1.62%. The results were compared favorably with those of a reference pre-validated method. The method is practical and valuable in terms of its routine application in quality control laboratories. PMID:22305461
ESR Measurement Of Crystallinity In Semicrystalline Polymers
NASA Technical Reports Server (NTRS)
Kim, Soon Sam; Tsay, Fun-Dow
1989-01-01
Photogenerated free radicals decay at different rates in crystalline and amorphous phases. Degree of crystallinity in polymer having both crystalline and amorphous phases measured indirectly by technique based in part on electron-spin-resonance (ESR) spectroscopy. Accuracy of crystallinity determined by new technique equals or exceeds similar determinations by differential scanning calorimetry, wide-angle x-ray scattering, or measurement of density.
40 CFR 53.55 - Test for effect of variations in power line voltage and ambient temperature.
Code of Federal Regulations, 2013 CFR
2013-07-01
... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within... absolute difference calculated in Equation 15 of this paragraph (g)(4) must not exceed 0.3 (CV%) for each test run. (5) Ambient temperature measurement accuracy. (i) Calculate the absolute value of the...
40 CFR 53.55 - Test for effect of variations in power line voltage and ambient temperature.
Code of Federal Regulations, 2014 CFR
2014-07-01
... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within... absolute difference calculated in Equation 15 of this paragraph (g)(4) must not exceed 0.3 (CV%) for each test run. (5) Ambient temperature measurement accuracy. (i) Calculate the absolute value of the...
Jiang, Jie; Yu, Wenbo; Zhang, Guangjun
2017-01-01
Navigation accuracy is one of the key performance indicators of an inertial navigation system (INS). Requirements for an accuracy assessment of an INS in a real work environment are exceedingly urgent because of enormous differences between real work and laboratory test environments. An attitude accuracy assessment of an INS based on the intensified high dynamic star tracker (IHDST) is particularly suitable for a real complex dynamic environment. However, the coupled systematic coordinate errors of an INS and the IHDST severely decrease the attitude assessment accuracy of an INS. Given that, a high-accuracy decoupling estimation method of the above systematic coordinate errors based on the constrained least squares (CLS) method is proposed in this paper. The reference frame of the IHDST is firstly converted to be consistent with that of the INS because their reference frames are completely different. Thereafter, the decoupling estimation model of the systematic coordinate errors is established and the CLS-based optimization method is utilized to estimate errors accurately. After compensating for error, the attitude accuracy of an INS can be assessed based on IHDST accurately. Both simulated experiments and real flight experiments of aircraft are conducted, and the experimental results demonstrate that the proposed method is effective and shows excellent performance for the attitude accuracy assessment of an INS in a real work environment. PMID:28991179
Structure and properties of corrosion and wear resistant Cr-Mn-N steels
NASA Astrophysics Data System (ADS)
Lenel, U. R.; Knott, B. R.
1987-06-01
Steels containing about 12 pct Cr, 10 pct Mn, and 0.2 pct N have been shown to have an unstable austenitic microstructure and have good ductility, extreme work hardening, high fracture strength, excellent toughness, good wear resistance, and moderate corrosion resistance. A series of alloys containing 9.5 to 12.8 pct Cr, 5.0 to 10.4 pct Mn, 0.16 to 0.32 pct N, 0.05 pct C, and residual elements typical of stainless steels was investigated by microstructural examination and mechanical, abrasion, and corrosion testing. Microstructures ranged from martensite to unstable austenite. The unstable austenitic steels transformed to α martensite on deformation and displayed very high work hardening, exceeding that of Hadfield’s manganese steels. Fracture strengths similar to high carbon martensitic stainless steels were obtained while ductility and toughness values were high, similar to austenitic stainless steels. Resistance to abrasive wear exceeded that of commercial abrasion resistant steels and other stainless steels. Corrosion resistance was similar to that of other 12 pct Cr steels. Properties were not much affected by minor compositional variations or rolled-in nitrogen porosity. In 12 pct Cr-10 pct Mn alloys, ingot porosity was avoided when nitrogen levels were below 0.19 pet, and austenitic microstructures were obtained when nitrogen levels exceeded 0.14 pct.
The purpose of this study is to better understand the differences and similarities between emergy and nonmarket economic valuation, when both are applied to value the same policies or development alternatives. The emdollar value of a good or service often exceeds the market value...
Parameters for good welding of copper to nickel
NASA Technical Reports Server (NTRS)
Hall, L. G.
1969-01-01
Quality in welding copper leads to nickel bus wires is obtained by the mass of nickel exceeding that of copper. Welding range 2ncreases proportionately with the increase in the nickel-to-copper mass ratio up to 4-to-1.
78 FR 8583 - Notice of Lodging of Proposed Consent Decree Under the Clean Air Act
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-06
... that resulted in exceedances of the national ambient air quality standard for lead, failed to use good air pollution control practices for minimizing lead emissions, and caused a common law nuisance at its...
NLT and extrapolated DLT:3-D cinematography alternatives for enlarging the volume of calibration.
Hinrichs, R N; McLean, S P
1995-10-01
This study investigated the accuracy of the direct linear transformation (DLT) and non-linear transformation (NLT) methods of 3-D cinematography/videography. A comparison of standard DLT, extrapolated DLT, and NLT calibrations showed the standard (non-extrapolated) DLT to be the most accurate, especially when a large number of control points (40-60) were used. The NLT was more accurate than the extrapolated DLT when the level of extrapolation exceeded 100%. The results indicated that when possible one should use the DLT with a control object, sufficiently large as to encompass the entire activity being studied. However, in situations where the activity volume exceeds the size of one's DLT control object, the NLT method should be considered.
Schueler, Sabine; Walther, Stefan; Schuetz, Georg M; Schlattmann, Peter; Dewey, Marc
2013-06-01
To evaluate the methodological quality of diagnostic accuracy studies on coronary computed tomography (CT) angiography using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) tool. Each QUADAS item was individually defined to adapt it to the special requirements of studies on coronary CT angiography. Two independent investigators analysed 118 studies using 12 QUADAS items. Meta-regression and pooled analyses were performed to identify possible effects of methodological quality items on estimates of diagnostic accuracy. The overall methodological quality of coronary CT studies was merely moderate. They fulfilled a median of 7.5 out of 12 items. Only 9 of the 118 studies fulfilled more than 75 % of possible QUADAS items. One QUADAS item ("Uninterpretable Results") showed a significant influence (P = 0.02) on estimates of diagnostic accuracy with "no fulfilment" increasing specificity from 86 to 90 %. Furthermore, pooled analysis revealed that each QUADAS item that is not fulfilled has the potential to change estimates of diagnostic accuracy. The methodological quality of studies investigating the diagnostic accuracy of non-invasive coronary CT is only moderate and was found to affect the sensitivity and specificity. An improvement is highly desirable because good methodology is crucial for adequately assessing imaging technologies. • Good methodological quality is a basic requirement in diagnostic accuracy studies. • Most coronary CT angiography studies have only been of moderate design quality. • Weak methodological quality will affect the sensitivity and specificity. • No improvement in methodological quality was observed over time. • Authors should consider the QUADAS checklist when undertaking accuracy studies.
Applications and accuracy of the parallel diagonal dominant algorithm
NASA Technical Reports Server (NTRS)
Sun, Xian-He
1993-01-01
The Parallel Diagonal Dominant (PDD) algorithm is a highly efficient, ideally scalable tridiagonal solver. In this paper, a detailed study of the PDD algorithm is given. First the PDD algorithm is introduced. Then the algorithm is extended to solve periodic tridiagonal systems. A variant, the reduced PDD algorithm, is also proposed. Accuracy analysis is provided for a class of tridiagonal systems, the symmetric, and anti-symmetric Toeplitz tridiagonal systems. Implementation results show that the analysis gives a good bound on the relative error, and the algorithm is a good candidate for the emerging massively parallel machines.
Chapon, P A; Bulla, J; Gauthier, A; Moussay, S
2014-04-01
This study aims to assess the thermal homogeneity of the intraperitoneal (IP) cavity and the relevance of using a fixed telemetric temperature sensor at a given location in studying rodents. Ten rats were intraperitoneally implanted with three Jonah® capsules each; after assessing the accuracy and reliability of the sensors. Two capsules were attached, one to the right iliac fossa (RIF) and the other to the left hypochondrium (LH), and another was placed between the intestines but not attached (Free). In the ex vivo condition, the differences between sensors and reference values remained in the range of ±0.1. In the in vivo condition, each sensor enabled the observation of temperature patterns. However, sensor location affected mean and median temperature values while the rats were moving freely. Indeed, temperature data collected in the LH were 0.1 significantly higher than those collected in the RIF and temperature data collected in the LH were 0.11 significantly higher than those collected with the Free capsules. In in vivo conditions, intra-sensor variability of temperature data was not affected by sensor location. Taking into account sensor accuracy, similar intra-sensor variability, and mean differences observed between the three locations, the impact of sensor location within the IP cavity could be considered negligible. In in vivo conditions, temperature differences between locations regularly exceeded ±0.2 and reached up to 2.5. These extreme values could be explained by behavioral factors such as food or water intake. Finally, considering the good thermal homogeneity of the IP cavity and possible adverse consequences of sensor attachment, it seems better to let sensors range free within the cavity.
Bhowmik, Avit Kumar; Alamdar, Ambreen; Katsoyiannis, Ioannis; Shen, Heqing; Ali, Nadeem; Ali, Syeda Maria; Bokhari, Habib; Schäfer, Ralf B; Eqani, Syed Ali Musstjab Akber Shah
2015-12-15
The consumption of contaminated drinking water is one of the major causes of mortality and many severe diseases in developing countries. The principal drinking water sources in Pakistan, i.e. ground and surface water, are subject to geogenic and anthropogenic trace metal contamination. However, water quality monitoring activities have been limited to a few administrative areas and a nationwide human health risk assessment from trace metal exposure is lacking. Using geographically weighted regression (GWR) and eight relevant spatial predictors, we calculated nationwide human health risk maps by predicting the concentration of 10 trace metals in the drinking water sources of Pakistan and comparing them to guideline values. GWR incorporated local variations of trace metal concentrations into prediction models and hence mitigated effects of large distances between sampled districts due to data scarcity. Predicted concentrations mostly exhibited high accuracy and low uncertainty, and were in good agreement with observed concentrations. Concentrations for Central Pakistan were predicted with higher accuracy than for the North and South. A maximum 150-200 fold exceedance of guideline values was observed for predicted cadmium concentrations in ground water and arsenic concentrations in surface water. In more than 53% (4 and 100% for the lower and upper boundaries of 95% confidence interval (CI)) of the total area of Pakistan, the drinking water was predicted to be at risk of contamination from arsenic, chromium, iron, nickel and lead. The area with elevated risks is inhabited by more than 74 million (8 and 172 million for the lower and upper boundaries of 95% CI) people. Although these predictions require further validation by field monitoring, the results can inform disease mitigation and water resources management regarding potential hot spots. Copyright © 2015 Elsevier B.V. All rights reserved.
Predicting turns in proteins with a unified model.
Song, Qi; Li, Tonghua; Cong, Peisheng; Sun, Jiangming; Li, Dapeng; Tang, Shengnan
2012-01-01
Turns are a critical element of the structure of a protein; turns play a crucial role in loops, folds, and interactions. Current prediction methods are well developed for the prediction of individual turn types, including α-turn, β-turn, and γ-turn, etc. However, for further protein structure and function prediction it is necessary to develop a uniform model that can accurately predict all types of turns simultaneously. In this study, we present a novel approach, TurnP, which offers the ability to investigate all the turns in a protein based on a unified model. The main characteristics of TurnP are: (i) using newly exploited features of structural evolution information (secondary structure and shape string of protein) based on structure homologies, (ii) considering all types of turns in a unified model, and (iii) practical capability of accurate prediction of all turns simultaneously for a query. TurnP utilizes predicted secondary structures and predicted shape strings, both of which have greater accuracy, based on innovative technologies which were both developed by our group. Then, sequence and structural evolution features, which are profile of sequence, profile of secondary structures and profile of shape strings are generated by sequence and structure alignment. When TurnP was validated on a non-redundant dataset (4,107 entries) by five-fold cross-validation, we achieved an accuracy of 88.8% and a sensitivity of 71.8%, which exceeded the most state-of-the-art predictors of certain type of turn. Newly determined sequences, the EVA and CASP9 datasets were used as independent tests and the results we achieved were outstanding for turn predictions and confirmed the good performance of TurnP for practical applications.
Predicting Turns in Proteins with a Unified Model
Song, Qi; Li, Tonghua; Cong, Peisheng; Sun, Jiangming; Li, Dapeng; Tang, Shengnan
2012-01-01
Motivation Turns are a critical element of the structure of a protein; turns play a crucial role in loops, folds, and interactions. Current prediction methods are well developed for the prediction of individual turn types, including α-turn, β-turn, and γ-turn, etc. However, for further protein structure and function prediction it is necessary to develop a uniform model that can accurately predict all types of turns simultaneously. Results In this study, we present a novel approach, TurnP, which offers the ability to investigate all the turns in a protein based on a unified model. The main characteristics of TurnP are: (i) using newly exploited features of structural evolution information (secondary structure and shape string of protein) based on structure homologies, (ii) considering all types of turns in a unified model, and (iii) practical capability of accurate prediction of all turns simultaneously for a query. TurnP utilizes predicted secondary structures and predicted shape strings, both of which have greater accuracy, based on innovative technologies which were both developed by our group. Then, sequence and structural evolution features, which are profile of sequence, profile of secondary structures and profile of shape strings are generated by sequence and structure alignment. When TurnP was validated on a non-redundant dataset (4,107 entries) by five-fold cross-validation, we achieved an accuracy of 88.8% and a sensitivity of 71.8%, which exceeded the most state-of-the-art predictors of certain type of turn. Newly determined sequences, the EVA and CASP9 datasets were used as independent tests and the results we achieved were outstanding for turn predictions and confirmed the good performance of TurnP for practical applications. PMID:23144872
40 CFR 52.990 - Stack height regulations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Section 52.990 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... emission limitation for a specific source exceeds the height allowed by Section 921(A) “Good Engineering... Department of Environmental Quality, dated September 23, 1986, stated that: In specific, the State regulation...
Analysis of Artificial Neural Network in Erosion Modeling: A Case Study of Serang Watershed
NASA Astrophysics Data System (ADS)
Arif, N.; Danoedoro, P.; Hartono
2017-12-01
Erosion modeling is an important measuring tool for both land users and decision makers to evaluate land cultivation and thus it is necessary to have a model to represent the actual reality. Erosion models are a complex model because of uncertainty data with different sources and processing procedures. Artificial neural networks can be relied on for complex and non-linear data processing such as erosion data. The main difficulty in artificial neural network training is the determination of the value of each network input parameters, i.e. hidden layer, momentum, learning rate, momentum, and RMS. This study tested the capability of artificial neural network application in the prediction of erosion risk with some input parameters through multiple simulations to get good classification results. The model was implemented in Serang Watershed, Kulonprogo, Yogyakarta which is one of the critical potential watersheds in Indonesia. The simulation results showed the number of iterations that gave a significant effect on the accuracy compared to other parameters. A small number of iterations can produce good accuracy if the combination of other parameters was right. In this case, one hidden layer was sufficient to produce good accuracy. The highest training accuracy achieved in this study was 99.32%, occurred in ANN 14 simulation with combination of network input parameters of 1 HL; LR 0.01; M 0.5; RMS 0.0001, and the number of iterations of 15000. The ANN training accuracy was not influenced by the number of channels, namely input dataset (erosion factors) as well as data dimensions, rather it was determined by changes in network parameters.
Mitsunaga, Tisha; Hedt-Gauthier, Bethany L; Ngizwenayo, Elias; Farmer, Didi Bertrand; Gaju, Erick; Drobac, Peter; Basinga, Paulin; Hirschhorn, Lisa; Rich, Michael L; Winch, Peter J; Ngabo, Fidele; Mugeni, Cathy
2015-08-01
Community health workers (CHWs) collect data for routine services, surveys and research in their communities. However, quality of these data is largely unknown. Utilizing poor quality data can result in inefficient resource use, misinformation about system gaps, and poor program management and effectiveness. This study aims to measure CHW data accuracy, defined as agreement between household registers compared to household member interview and client records in one district in Eastern province, Rwanda. We used cluster-lot quality assurance sampling to randomly sample six CHWs per cell and six households per CHW. We classified cells as having 'poor' or 'good' accuracy for household registers for five indicators, calculating point estimates of percent of households with accurate data by health center. We evaluated 204 CHW registers and 1,224 households for accuracy across 34 cells in southern Kayonza. Point estimates across health centers ranged from 79 to 100% for individual indicators and 61 to 72% for the composite indicator. Recording error appeared random for all but the widely under-reported number of women on modern family planning method. Overall, accuracy was largely 'good' across cells, with varying results by indicator. Program managers should identify optimum thresholds for 'good' data quality and interventions to reach them according to data use. Decreasing variability and improving quality will facilitate potential of these routinely-collected data to be more meaningful for community health program management. We encourage further studies assessing CHW data quality and the impact training, supervision and other strategies have on improving it.
NASA Astrophysics Data System (ADS)
Markov, Yu. G.; Mikhailov, M. V.; Pochukaev, V. N.
2012-07-01
An analysis of perturbing factors influencing the motion of a navigation satellite (NS) is carried out, and the degree of influence of each factor on the GLONASS orbit is estimated. It is found that fundamental components of the Earth's rotation parameters (ERP) are one substantial factor commensurable with maximum perturbations. Algorithms for the calculation of orbital perturbations caused by these parameters are given; these algorithms can be implemented in a consumer's equipment. The daily prediction of NS coordinates is performed on the basis of real GLONASS satellite ephemerides transmitted to a consumer, using the developed prediction algorithms taking the ERP into account. The obtained accuracy of the daily prediction of GLONASS ephemerides exceeds by tens of times the accuracy of the daily prediction performed using algorithms recommended in interface control documents.
High Accuracy Acoustic Relative Humidity Measurement in Duct Flow with Air
van Schaik, Wilhelm; Grooten, Mart; Wernaart, Twan; van der Geld, Cees
2010-01-01
An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity (RH) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0–12 m/s with an error of ±0.13 m/s, temperature 0–100 °C with an error of ±0.07 °C and relative humidity 0–100% with accuracy better than 2 % RH above 50 °C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 °C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments. PMID:22163610
High accuracy acoustic relative humidity measurement in duct flow with air.
van Schaik, Wilhelm; Grooten, Mart; Wernaart, Twan; van der Geld, Cees
2010-01-01
An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity (RH) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0-12 m/s with an error of ± 0.13 m/s, temperature 0-100 °C with an error of ± 0.07 °C and relative humidity 0-100% with accuracy better than 2 % RH above 50 °C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 °C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments.
Endeshaw, Tekola; Graves, Patricia M.; Ayele, Berhan; Mosher, Aryc W.; Gebre, Teshome; Ayalew, Firew; Genet, Asrat; Mesfin, Alemayehu; Shargie, Estifanos Biru; Tadesse, Zerihun; Teferi, Tesfaye; Melak, Berhanu; Richards, Frank O.; Emerson, Paul M.
2012-01-01
Background Diagnostic tests are recommended for suspected malaria cases before treatment, but comparative performance of microscopy and rapid diagnostic tests (RDTs) at rural health centers has rarely been studied compared to independent expert microscopy. Methods Participants (N = 1997) with presumptive malaria were recruited from ten health centers with a range of transmission intensities in Amhara Regional State, Northwest Ethiopia during October to December 2007. Microscopy and ParaScreen Pan/Pf® RDT were done immediately by health center technicians. Blood slides were re-examined later at a central laboratory by independent expert microscopists. Results Of 1,997 febrile patients, 475 (23.8%) were positive by expert microscopists, with 57.7% P.falciparum, 24.6% P.vivax and 17.7% mixed infections. Sensitivity of health center microscopists for any malaria species was >90% in five health centers (four of which had the highest prevalence), >70% in nine centers and 44% in one site with lowest prevalence. Specificity for health center microscopy was very good (>95%) in all centers. For ParaScreen RDT, sensitivity was ≥90% in three centers, ≥70% in six and <60% in four centers. Specificity was ≥90% in all centers except one where it was 85%. Conclusions Health center microscopists performed well in nine of the ten health centers; while for ParaScreen RDT they performed well in only six centers. Overall the accuracy of local microscopy exceeded that of RDT for all outcomes. This study supports the introduction of RDTs only if accompanied by appropriate training, frequent supervision and quality control at all levels. Deficiencies in RDT use at some health centers must be rectified before universal replacement of good routine microscopy with RDTs. Maintenance and strengthening of good quality microscopy remains a priority at health center level. PMID:22536317
Endeshaw, Tekola; Graves, Patricia M; Ayele, Berhan; Mosher, Aryc W; Gebre, Teshome; Ayalew, Firew; Genet, Asrat; Mesfin, Alemayehu; Shargie, Estifanos Biru; Tadesse, Zerihun; Teferi, Tesfaye; Melak, Berhanu; Richards, Frank O; Emerson, Paul M
2012-01-01
Diagnostic tests are recommended for suspected malaria cases before treatment, but comparative performance of microscopy and rapid diagnostic tests (RDTs) at rural health centers has rarely been studied compared to independent expert microscopy. Participants (N = 1997) with presumptive malaria were recruited from ten health centers with a range of transmission intensities in Amhara Regional State, Northwest Ethiopia during October to December 2007. Microscopy and ParaScreen Pan/Pf® RDT were done immediately by health center technicians. Blood slides were re-examined later at a central laboratory by independent expert microscopists. Of 1,997 febrile patients, 475 (23.8%) were positive by expert microscopists, with 57.7% P. falciparum, 24.6% P. vivax and 17.7% mixed infections. Sensitivity of health center microscopists for any malaria species was >90% in five health centers (four of which had the highest prevalence), >70% in nine centers and 44% in one site with lowest prevalence. Specificity for health center microscopy was very good (>95%) in all centers. For ParaScreen RDT, sensitivity was ≥90% in three centers, ≥70% in six and <60% in four centers. Specificity was ≥90% in all centers except one where it was 85%. Health center microscopists performed well in nine of the ten health centers; while for ParaScreen RDT they performed well in only six centers. Overall the accuracy of local microscopy exceeded that of RDT for all outcomes. This study supports the introduction of RDTs only if accompanied by appropriate training, frequent supervision and quality control at all levels. Deficiencies in RDT use at some health centers must be rectified before universal replacement of good routine microscopy with RDTs. Maintenance and strengthening of good quality microscopy remains a priority at health center level.
Accuracy of Estimating Solar Radiation Pressure for GEO Debris with Tumbling Effect
NASA Astrophysics Data System (ADS)
Chao, Chia-Chun George
2009-03-01
The accuracy of estimating solar radiation pressure for GEO debris is examined and demonstrated, via numerical simulations, by fitting a batch (months) of simulated position vectors. These simulated position vectors are generated from a "truth orbit" with added white noise using high-precision numerical integration tools. After the long-arc fit of the simulated observations (position vectors), one can accurately and reliably determine how close the estimated value of solar radiation pressure is to the truth. Results of this study show that the inherent accuracy in estimating the solar radiation pressure coefficient can be as good as 1% if a long-arc fit span up to 180 days is used and the satellite is not tumbling. The corresponding position prediction accuracy can be as good as, in maximum error, 1 km along in-track, 0.3 km along radial and 0.1 km along cross-track up to 30 days. Similar accuracies can be expected when the object is tumbling as long as the rate of attitude change is different from the orbit rate. Results of this study reveal an important phenomenon that the solar radiation pressure significantly affects the orbit motion when the spin rate is equal to the orbit rate.
Alcohol use among university students: Considering a positive deviance approach.
Tucker, Maryanne; Harris, Gregory E
2016-09-01
Harmful alcohol consumption among university students continues to be a significant issue. This study examined whether variables identified in the positive deviance literature would predict responsible alcohol consumption among university students. Surveyed students were categorized into three groups: abstainers, responsible drinkers and binge drinkers. Multinomial logistic regression modelling was significant (χ(2) = 274.49, degrees of freedom = 24, p < .001), with several variables predicting group membership. While the model classification accuracy rate (i.e. 71.2%) exceeded the proportional by chance accuracy rate (i.e. 38.4%), providing further support for the model, the model itself best predicted binge drinker membership over the other two groups. © The Author(s) 2015.
Code of Federal Regulations, 2010 CFR
2010-07-01
...-accuracy test PS 8 requires. (3) If you continuously monitor VOC emissions using gas chromatography, you... percent of the span value (or more than 10 percent of the calibration gas value if your CEMS is a gas... calibration drift exceeds 5 percent of the span value (or more than 20 percent of the calibration gas value...
Code of Federal Regulations, 2011 CFR
2011-07-01
...-accuracy test PS 8 requires. (3) If you continuously monitor VOC emissions using gas chromatography, you... percent of the span value (or more than 10 percent of the calibration gas value if your CEMS is a gas... calibration drift exceeds 5 percent of the span value (or more than 20 percent of the calibration gas value...
Airbreathing hypersonic vehicle design and analysis methods
NASA Technical Reports Server (NTRS)
Lockwood, Mary Kae; Petley, Dennis H.; Hunt, James L.; Martin, John G.
1996-01-01
The design, analysis, and optimization of airbreathing hypersonic vehicles requires analyses involving many highly coupled disciplines at levels of accuracy exceeding those traditionally considered in a conceptual or preliminary-level design. Discipline analysis methods including propulsion, structures, thermal management, geometry, aerodynamics, performance, synthesis, sizing, closure, and cost are discussed. Also, the on-going integration of these methods into a working environment, known as HOLIST, is described.
40 CFR 53.55 - Test for effect of variations in power line voltage and ambient temperature.
Code of Federal Regulations, 2012 CFR
2012-07-01
... temperatures used in the tests and shall be checked at zero and at least one flow rate within ±3 percent of 16... absolute difference calculated in Equation 15 of this paragraph (g)(4) must not exceed 0.3 (CV%) for each test run. (5) Ambient temperature measurement accuracy. (i) Calculate the absolute value of the...
40 CFR 53.55 - Test for effect of variations in power line voltage and ambient temperature.
Code of Federal Regulations, 2011 CFR
2011-07-01
... temperatures used in the tests and shall be checked at zero and at least one flow rate within ±3 percent of 16... absolute difference calculated in Equation 15 of this paragraph (g)(4) must not exceed 0.3 (CV%) for each test run. (5) Ambient temperature measurement accuracy. (i) Calculate the absolute value of the...
49 CFR 178.358-3 - Modification of Specification 21PF-1 overpacks.
Code of Federal Regulations, 2011 CFR
2011-10-01
... rate of weight loss is less than 1.1 kg (2.5 pounds) per day. (5) As an alternate moisture measurement... (top and bottom halves) separately to an accuracy of ±2.3 kg (±5 pounds) and record the weights. If this measured weight exceeds the initially measured weight at the time of fabrication by 11.3 kg (25...
49 CFR 178.358-3 - Modification of Specification 21PF-1 overpacks.
Code of Federal Regulations, 2010 CFR
2010-10-01
... rate of weight loss is less than 1.1 kg (2.5 pounds) per day. (5) As an alternate moisture measurement... (top and bottom halves) separately to an accuracy of ±2.3 kg (±5 pounds) and record the weights. If this measured weight exceeds the initially measured weight at the time of fabrication by 11.3 kg (25...
40 CFR 86.1338-84 - Emission measurement accuracy.
Code of Federal Regulations, 2010 CFR
2010-07-01
... engineering practice dictates that exhaust emission sample analyzer readings below 15 percent of full scale... computers, data loggers, etc., can provide sufficient accuracy and resolution below 15 percent of full scale... spaced points, using good engineering judgement, below 15 percent of full scale are made to ensure the...
40 CFR 86.1338-84 - Emission measurement accuracy.
Code of Federal Regulations, 2013 CFR
2013-07-01
... engineering practice dictates that exhaust emission sample analyzer readings below 15 percent of full scale... computers, data loggers, etc., can provide sufficient accuracy and resolution below 15 percent of full scale... spaced points, using good engineering judgement, below 15 percent of full scale are made to ensure the...
40 CFR 86.1338-84 - Emission measurement accuracy.
Code of Federal Regulations, 2012 CFR
2012-07-01
... engineering practice dictates that exhaust emission sample analyzer readings below 15 percent of full scale... computers, data loggers, etc., can provide sufficient accuracy and resolution below 15 percent of full scale... spaced points, using good engineering judgement, below 15 percent of full scale are made to ensure the...
40 CFR 86.1338-84 - Emission measurement accuracy.
Code of Federal Regulations, 2011 CFR
2011-07-01
... engineering practice dictates that exhaust emission sample analyzer readings below 15 percent of full scale... computers, data loggers, etc., can provide sufficient accuracy and resolution below 15 percent of full scale... spaced points, using good engineering judgement, below 15 percent of full scale are made to ensure the...
Sampling strategies to improve passive optical remote sensing of river bathymetry
Legleiter, Carl; Overstreet, Brandon; Kinzel, Paul J.
2018-01-01
Passive optical remote sensing of river bathymetry involves establishing a relation between depth and reflectance that can be applied throughout an image to produce a depth map. Building upon the Optimal Band Ratio Analysis (OBRA) framework, we introduce sampling strategies for constructing calibration data sets that lead to strong relationships between an image-derived quantity and depth across a range of depths. Progressively excluding observations that exceed a series of cutoff depths from the calibration process improved the accuracy of depth estimates and allowed the maximum detectable depth ($d_{max}$) to be inferred directly from an image. Depth retrieval in two distinct rivers also was enhanced by a stratified version of OBRA that partitions field measurements into a series of depth bins to avoid biases associated with under-representation of shallow areas in typical field data sets. In the shallower, clearer of the two rivers, including the deepest field observations in the calibration data set did not compromise depth retrieval accuracy, suggesting that $d_{max}$ was not exceeded and the reach could be mapped without gaps. Conversely, in the deeper and more turbid stream, progressive truncation of input depths yielded a plausible estimate of $d_{max}$ consistent with theoretical calculations based on field measurements of light attenuation by the water column. This result implied that the entire channel, including pools, could not be mapped remotely. However, truncation improved the accuracy of depth estimates in areas shallower than $d_{max}$, which comprise the majority of the channel and are of primary interest for many habitat-oriented applications.
NASA Technical Reports Server (NTRS)
Hashmall, J.; Davis, W.; Harman, R.
1993-01-01
The science mission of the Extreme Ultraviolet Explorer (EUVE) requires attitude solutions with uncertainties of 27, 16.7, 16.7 arcseconds (3 sigma) around the roll, pitch, and yaw axes, respectively. The primary input to the attitude determination process is provided by two NASA standard fixed-head star trackers (FHSTs) and a Teledyne dry rotor inertial reference unit (DRIRU) 2. The attitude determination requirements approach the limits attainable with the FHSTs and DRIRU. The Flight Dynamics Facility (FDF) at Goddard Space Flight Center (GSFC) designed and executed calibration procedures that far exceeded the extent and the data volume of any other FDF-supported mission. The techniques and results of this attempt to obtain attitude accuracies at the limit of sensor capability and the results of analysis of the factors that limit the attitude accuracy are the primary subjects of this paper. The success of the calibration effort is judged by the resulting measurement residuals and comparisons between ground- and onboard-determined attitudes. The FHST star position residuals have been reduced to less tha 4 arcsec per axis -- a value that appears to be limited by the sensor capabilities. The FDF ground system uses a batch least-squares estimator to determine attitude. The EUVE onboard computer (OBC) uses an extended Kalman filter. Currently, there are systematic differences between the two attitude solutions that occasionally exceed the mission requirements for 3 sigma attitude uncertainty. Attempts to understand and reduce these differences are continuing.
Accuracy of Satellite Optical Observations and Precise Orbit Determination
NASA Astrophysics Data System (ADS)
Shakun, L.; Koshkin, N.; Korobeynikova, E.; Strakhova, S.; Dragomiretsky, V.; Ryabov, A.; Melikyants, S.; Golubovskaya, T.; Terpan, S.
The monitoring of low-orbit space objects (LEO-objects) is performed in the Astronomical Observatory of Odessa I.I. Mechnikov National University (Ukraine) for many years. Decades-long archives of these observations are accessible within Ukrainian network of optical observers (UMOS). In this work, we give an example of orbit determination for the satellite with the 1500-km height of orbit based on angular observations in our observatory (Int. No. 086). For estimation of the measurement accuracy and accuracy of determination and propagation of satellite position, we analyze the observations of Ajisai satellite with the well-determined orbit. This allows making justified conclusions not only about random errors of separate measurements, but also to analyze the presence of systematic errors, including external ones to the measurement process. We have shown that the accuracy of one measurement has the standard deviation about 1 arcsec across the track and 1.4 arcsec along the track and systematical shifts in measurements of one track do not exceed 0.45 arcsec. Ajisai position in the interval of the orbit fitting is predicted with accuracy better than 30 m along the orbit and better than 10 m across the orbit for any its point.
Code of Federal Regulations, 2011 CFR
2011-10-01
... off-road vehicle may be operated on public lands unless equipped with brakes in good working condition... excessive noise exceeding Environmental Protection Agency standards, when established, may be operated on public lands. (c) By posting appropriate signs or by marking a map which shall be available for public...
7 CFR 1980.391 - Equity sharing.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., principal reduction, and value added by any capital improvements. (i) Market value. Market value of the... amount of the insurance payment is generally a good indication of value; however, tax records or... exceed market value contribution as indicated by a sales comparison analysis. Generally, the value added...
7 CFR 1980.391 - Equity sharing.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., principal reduction, and value added by any capital improvements. (i) Market value. Market value of the... amount of the insurance payment is generally a good indication of value; however, tax records or... exceed market value contribution as indicated by a sales comparison analysis. Generally, the value added...
7 CFR 1980.391 - Equity sharing.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., principal reduction, and value added by any capital improvements. (i) Market value. Market value of the... amount of the insurance payment is generally a good indication of value; however, tax records or... exceed market value contribution as indicated by a sales comparison analysis. Generally, the value added...
7 CFR 1980.391 - Equity sharing.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., principal reduction, and value added by any capital improvements. (i) Market value. Market value of the... amount of the insurance payment is generally a good indication of value; however, tax records or... exceed market value contribution as indicated by a sales comparison analysis. Generally, the value added...
7 CFR 1980.391 - Equity sharing.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., principal reduction, and value added by any capital improvements. (i) Market value. Market value of the... amount of the insurance payment is generally a good indication of value; however, tax records or... exceed market value contribution as indicated by a sales comparison analysis. Generally, the value added...
de Paula, Adelzon Assis; Pires, Denise Franqueira; Filho, Pedro Alves; de Lemos, Kátia Regina Valente; Barçante, Eduardo; Pacheco, Antonio Guilherme
2018-06-01
While cross-referencing information from people living with HIV/AIDS (PLWHA) to the official mortality database is a critical step in monitoring the HIV/AIDS epidemic in Brazil, the accuracy of the linkage routine may compromise the validity of the final database, yielding to biased epidemiological estimates. We compared the accuracy and the total runtime of two linkage algorithms applied to retrieve vital status information from PLWHA in Brazilian public databases. Nominally identified records from PLWHA were obtained from three distinct government databases. Linkage routines included an algorithm in Python language (PLA) and Reclink software (RlS), a probabilistic software largely utilized in Brazil. Records from PLWHA 1 known to be alive were added to those from patients reported as deceased. Data were then searched into the mortality system. Scenarios where 5% and 50% of patients actually dead were simulated, considering both complete cases and 20% missing maternal names. When complete information was available both algorithms had comparable accuracies. In the scenario of 20% missing maternal names, PLA 2 and RlS 3 had sensitivities of 94.5% and 94.6% (p > 0.5), respectively; after manual reviewing, PLA sensitivity increased to 98.4% (96.6-100.0) exceeding that for RlS (p < 0.01). PLA had higher positive predictive value in 5% death proportion. Manual reviewing was intrinsically required by RlS in up to 14% register for people actually dead, whereas the corresponding proportion ranged from 1.5% to 2% for PLA. The lack of manual inspection did not alter PLA sensitivity when complete information was available. When incomplete data was available PLA sensitivity increased from 94.5% to 98.4%, thus exceeding that presented by RlS (94.6%, p < 0.05). RlS spanned considerably less processing time compared to PLA. Both linkage algorithms presented interchangeable accuracies in retrieving vital status data from PLWHA. RlS had a considerably lesser runtime but intrinsically required manually reviewing a fastidious proportion of the matched registries. On the other hand, PLA spent quite more runtime but spared manual reviewing at no expense of accuracy. Copyright © 2018 Elsevier B.V. All rights reserved.
The effect of suspended sediment and color on ultraviolet spectrophotometric nitrate sensors
Snazelle, Teri T.
2016-03-08
Four commercially available ultraviolet nitrate spectrophotometric sensors were evaluated by the U.S. Geological Survey Hydrologic Instrumentation Facility (HIF) to determine the effects of suspended sediment concentration (SSC) and colored dissolved organic matter (CDOM) on sensor accuracy. The evaluated sensors were: the Hach NITRATAX plus sc (5-millimeters (mm) path length), Hach NITRATAX plus sc (2 mm), S::CAN Spectro::lyser (5 mm), and the Satlantic SUNA V2 (5 mm). A National Institute of Standards and Technology-traceable nitrate-free sediment standard was purchased and used to create the turbid environment, and an easily made filtered tea solution was used for the CDOM test. All four sensors performed well in the test that evaluated the effect of suspended sediment on accuracy. The Hach 5 mm, Hach 2 mm, and the SUNA V2 met their respective manufacturer accuracy specifications up to concentrations of 4,500 milligrams per liter (mg/L) SSC. The S::CAN failed to meet its accuracy specifications when the SSC concentrations exceeded 4,000 mg/L. Test results from the effect of CDOM on accuracy indicated a significant skewing of data from all four sensors and showed an artificial elevation of measured nitrate to varying amounts. Of the four sensors tested, the Satlantic SUNA V2’s accuracy was affected the least in the CDOM test. The nitrate concentration measured by the SUNA V2 was approximately 24 percent higher than the actual concentration when estimated total organic carbon values exceeded 44 mg/L. Measured nitrate concentration falsely increased 49 percent when measured by the Hach 5 mm, and 75 percent when measured by the Hach 2 mm. The S::CAN’s reported nitrate concentration increased 96 percent. Path length plays an important role in the sensor’s ability to compensate measurements for matrix interferences, but does not solely determine how well a sensor can handle all interferences. The sensor’s proprietary algorithms also play a key role in matrix interference compensation. The sensors’ ability to compensate for CDOM varied significantly during the tests, even among the three with 5-mm path lengths. Results of this evaluation suggest that the proprietary algorithms of the nitrate analyzers are more effective compensating for suspended sediment, and less effective compensating for CDOM (color) when sensor path length remains constant.
Evaluation of trade influence on economic growth rate by computational intelligence approach
NASA Astrophysics Data System (ADS)
Sokolov-Mladenović, Svetlana; Milovančević, Milos; Mladenović, Igor
2017-01-01
In this study was analyzed the influence of trade parameters on the economic growth forecasting accuracy. Computational intelligence method was used for the analyzing since the method can handle highly nonlinear data. It is known that the economic growth could be modeled based on the different trade parameters. In this study five input parameters were considered. These input parameters were: trade in services, exports of goods and services, imports of goods and services, trade and merchandise trade. All these parameters were calculated as added percentages in gross domestic product (GDP). The main goal was to select which parameters are the most impactful on the economic growth percentage. GDP was used as economic growth indicator. Results show that the imports of goods and services has the highest influence on the economic growth forecasting accuracy.
Loi, Gianfranco; Dominietto, Marco; Manfredda, Irene; Mones, Eleonora; Carriero, Alessandro; Inglese, Eugenio; Krengli, Marco; Brambilla, Marco
2008-09-01
This note describes a method to characterize the performances of image fusion software (Syntegra) with respect to accuracy and robustness. Computed tomography (CT), magnetic resonance imaging (MRI), and single-photon emission computed tomography (SPECT) studies were acquired from two phantoms and 10 patients. Image registration was performed independently by two couples composed of one radiotherapist and one physicist by means of superposition of anatomic landmarks. Each couple performed jointly and saved the registration. The two solutions were averaged to obtain the gold standard registration. A new set of estimators was defined to identify translation and rotation errors in the coordinate axes, independently from point position in image field of view (FOV). Algorithms evaluated were local correlation (LC) for CT-MRI, normalized mutual information (MI) for CT-MRI, and CT-SPECT registrations. To evaluate accuracy, estimator values were compared to limiting values for the algorithms employed, both in phantoms and in patients. To evaluate robustness, different alignments between images taken from a sample patient were produced and registration errors determined. LC algorithm resulted accurate in CT-MRI registrations in phantoms, but exceeded limiting values in 3 of 10 patients. MI algorithm resulted accurate in CT-MRI and CT-SPECT registrations in phantoms; limiting values were exceeded in one case in CT-MRI and never reached in CT-SPECT registrations. Thus, the evaluation of robustness was restricted to the algorithm of MI both for CT-MRI and CT-SPECT registrations. The algorithm of MI proved to be robust: limiting values were not exceeded with translation perturbations up to 2.5 cm, rotation perturbations up to 10 degrees and roto-translational perturbation up to 3 cm and 5 degrees.
NASA Astrophysics Data System (ADS)
Moghimi, Saba; Kushki, Azadeh; Power, Sarah; Guerguerian, Anne Marie; Chau, Tom
2012-04-01
Emotional responses can be induced by external sensory stimuli. For severely disabled nonverbal individuals who have no means of communication, the decoding of emotion may offer insight into an individual’s state of mind and his/her response to events taking place in the surrounding environment. Near-infrared spectroscopy (NIRS) provides an opportunity for bed-side monitoring of emotions via measurement of hemodynamic activity in the prefrontal cortex, a brain region known to be involved in emotion processing. In this paper, prefrontal cortex activity of ten able-bodied participants was monitored using NIRS as they listened to 78 music excerpts with different emotional content and a control acoustic stimuli consisting of the Brown noise. The participants rated their emotional state after listening to each excerpt along the dimensions of valence (positive versus negative) and arousal (intense versus neutral). These ratings were used to label the NIRS trial data. Using a linear discriminant analysis-based classifier and a two-dimensional time-domain feature set, trials with positive and negative emotions were discriminated with an average accuracy of 71.94% ± 8.19%. Trials with audible Brown noise representing a neutral response were differentiated from high arousal trials with an average accuracy of 71.93% ± 9.09% using a two-dimensional feature set. In nine out of the ten participants, response to the neutral Brown noise was differentiated from high arousal trials with accuracies exceeding chance level, and positive versus negative emotional differentiation accuracies exceeded the chance level in seven out of the ten participants. These results illustrate that NIRS recordings of the prefrontal cortex during presentation of music with emotional content can be automatically decoded in terms of both valence and arousal encouraging future investigation of NIRS-based emotion detection in individuals with severe disabilities.
Inter-arch digital model vs. manual cast measurements: Accuracy and reliability.
Kiviahde, Heikki; Bukovac, Lea; Jussila, Päivi; Pesonen, Paula; Sipilä, Kirsi; Raustia, Aune; Pirttiniemi, Pertti
2017-06-28
The purpose of this study was to evaluate the accuracy and reliability of inter-arch measurements using digital dental models and conventional dental casts. Thirty sets of dental casts with permanent dentition were examined. Manual measurements were done with a digital caliper directly on the dental casts, and digital measurements were made on 3D models by two independent examiners. Intra-class correlation coefficients (ICC), a paired sample t-test or Wilcoxon signed-rank test, and Bland-Altman plots were used to evaluate intra- and inter-examiner error and to determine the accuracy and reliability of the measurements. The ICC values were generally good for manual and excellent for digital measurements. The Bland-Altman plots of all the measurements showed good agreement between the manual and digital methods and excellent inter-examiner agreement using the digital method. Inter-arch occlusal measurements on digital models are accurate and reliable and are superior to manual measurements.
Optimizing the Terzaghi Estimator of the 3D Distribution of Rock Fracture Orientations
NASA Astrophysics Data System (ADS)
Tang, Huiming; Huang, Lei; Juang, C. Hsein; Zhang, Junrong
2017-08-01
Orientation statistics are prone to bias when surveyed with the scanline mapping technique in which the observed probabilities differ, depending on the intersection angle between the fracture and the scanline. This bias leads to 1D frequency statistical data that are poorly representative of the 3D distribution. A widely accessible estimator named after Terzaghi was developed to estimate 3D frequencies from 1D biased observations, but the estimation accuracy is limited for fractures at narrow intersection angles to scanlines (termed the blind zone). Although numerous works have concentrated on accuracy with respect to the blind zone, accuracy outside the blind zone has rarely been studied. This work contributes to the limited investigations of accuracy outside the blind zone through a qualitative assessment that deploys a mathematical derivation of the Terzaghi equation in conjunction with a quantitative evaluation that uses fractures simulation and verification of natural fractures. The results show that the estimator does not provide a precise estimate of 3D distributions and that the estimation accuracy is correlated with the grid size adopted by the estimator. To explore the potential for improving accuracy, the particular grid size producing maximum accuracy is identified from 168 combinations of grid sizes and two other parameters. The results demonstrate that the 2° × 2° grid size provides maximum accuracy for the estimator in most cases when applied outside the blind zone. However, if the global sample density exceeds 0.5°-2, then maximum accuracy occurs at a grid size of 1° × 1°.
The role of natural analogs in the repository licensing process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murphy, W.M.
1995-09-01
The concept of a permanent geologic repository for high-level nuclear waste (NLW) is implicitly based on analogy to natural systems that have been stable for millions or billions of years. The time of radioactive and chemical toxicity of HLW exceeds the duration of human civilization, and it is impossible to demonstrate the accuracy of predictions of the behavior of engineered or social systems over such long periods.
Criminal Code (Amendment) (No. 2) Act, 1988, (No. 1 of 1988), 5 February 1988.
1988-01-01
Among other things, this Act adds the following new section to the Saint Lucia Criminal Code: "112A. Any person who commits an act of indecency with or towards a child under the age of fourteen or who incites or encourages a child under that age to commit such an act with him or with another person is liable on conviction on indictment to imprisonment for two years or on summary conviction to imprisonment for six months or to a fine not exceeding one thousand dollars." The Act also changes the criminal penalty for keeping a brothel. Henceforth a person who is guilty of the crime is subject to a fine not exceeding $5,000 or to imprisonment for twelve months. In addition, that person may be required "to enter into a recognisance with or without securities to be of good behaviour for any period not exceeding one year; and in default of compliance with such recognisance is liable to imprisonment for a further period not exceeding six months." full text
Kang, Jian; Li, Xin; Jin, Rui; Ge, Yong; Wang, Jinfeng; Wang, Jianghao
2014-01-01
The eco-hydrological wireless sensor network (EHWSN) in the middle reaches of the Heihe River Basin in China is designed to capture the spatial and temporal variability and to estimate the ground truth for validating the remote sensing productions. However, there is no available prior information about a target variable. To meet both requirements, a hybrid model-based sampling method without any spatial autocorrelation assumptions is developed to optimize the distribution of EHWSN nodes based on geostatistics. This hybrid model incorporates two sub-criteria: one for the variogram modeling to represent the variability, another for improving the spatial prediction to evaluate remote sensing productions. The reasonability of the optimized EHWSN is validated from representativeness, the variogram modeling and the spatial accuracy through using 15 types of simulation fields generated with the unconditional geostatistical stochastic simulation. The sampling design shows good representativeness; variograms estimated by samples have less than 3% mean error relative to true variograms. Then, fields at multiple scales are predicted. As the scale increases, estimated fields have higher similarities to simulation fields at block sizes exceeding 240 m. The validations prove that this hybrid sampling method is effective for both objectives when we do not know the characteristics of an optimized variables. PMID:25317762
Martinc, Boštjan; Roškar, Robert; Grabnar, Iztok; Vovk, Tomaž
2014-07-01
Therapeutic drug monitoring (TDM) of antiepileptic drugs (AEDs) has been recognized as a useful tool in management of epilepsy. We developed a simple analytical method for simultaneous determination of four second generation AEDs, including gabapentin (GBP), pregabalin (PGB), vigabatrin (VGB), and topiramate (TOP). Analytes were extracted from human plasma using universal solid phase extraction, derivatized with 4-chloro-7-nitrobenzofurazan (NBD-Cl) and analyzed by HPLC with fluorescence detection. Using mass spectrometry we confirmed that NBD-Cl reacts with sulfamate group of TOP similarly as with amine group of the other three analytes. The method is linear (r(2)>0.998) across investigated analytical ranges (0.375-30.0μg/mL for GBP, PGB, and VGB; 0.50-20.0μg/mL for TOP). Intraday and interday precision do not exceed 9.40%. The accuracy is from 95.6% to 106%. The recovery is higher than 80.6%, and the lower limit of quantification is at least 0.5μg/mL. The method is selective and robust. For TOP determination the method was compared to a previously published method and the results obtained by the two methods were in good agreement. The developed method is suitable for routine TDM. Copyright © 2014 Elsevier B.V. All rights reserved.
Effective Fragment Potential Method for H-Bonding: How To Obtain Parameters for Nonrigid Fragments.
Dubinets, Nikita; Slipchenko, Lyudmila V
2017-07-20
Accuracy of the effective fragment potential (EFP) method was explored for describing intermolecular interaction energies in three dimers with strong H-bonded interactions, formic acid, formamide, and formamidine dimers, which are a part of HBC6 database of noncovalent interactions. Monomer geometries in these dimers change significantly as a function of intermonomer separation. Several EFP schemes were considered, in which fragment parameters were prepared for a fragment in its gas-phase geometry or recomputed for each unique fragment geometry. Additionally, a scheme in which gas-phase fragment parameters are shifted according to relaxed fragment geometries is introduced and tested. EFP data are compared against the coupled cluster with single, double, and perturbative triple excitations (CCSD(T)) method in a complete basis set (CBS) and the symmetry adapted perturbation theory (SAPT). All considered EFP schemes provide a good agreement with CCSD(T)/CBS for binding energies at equilibrium separations, with discrepancies not exceeding 2 kcal/mol. However, only the schemes that utilize relaxed fragment geometries remain qualitatively correct at shorter than equilibrium intermolecular distances. The EFP scheme with shifted parameters behaves quantitatively similar to the scheme in which parameters are recomputed for each monomer geometry and thus is recommended as a computationally efficient approach for large-scale EFP simulations of flexible systems.
LLNL/Lion Precision LVDT amplifier
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hopkins, D.J.
1994-04-01
A high-precision, low-noise, LVDT amplifier has been developed which is a significant advancement on the current state of the art in contact displacement measurement. This amplifier offers the dynamic range of a typical LVDT probe but with a resolution that rivals that of non contact displacement measuring systems such as capacitance gauges and laser interferometers. Resolution of 0.1 {mu} in with 100 Hz bandwidth is possible. This level of resolution is over an order of magnitude greater than what is now commercially available. A front panel switch can reduce the bandwidth to 2.5 Hz and attain a resolution of 0.025more » {mu} in. This level of resolution meets or exceeds that of displacement measuring laser interferometry or capacitance gauge systems. Contact displacement measurement offers high part spatial resolution and therefore can measure not only part contour but surface finish. Capacitance gauges and displacement laser interferometry offer poor part spatial resolution and can not provide good surface finish measurements. Machine tool builders, meteorologists and quality inspection departments can immediately utilize the higher accuracy and capabilities that this amplifier offers. The precision manufacturing industry can improve as a result of improved capability to measure parts that help reduce costs and minimize material waste.« less
NASA Astrophysics Data System (ADS)
Fang, Kaizheng; Mu, Daobin; Chen, Shi; Wu, Borong; Wu, Feng
2012-06-01
In this study, a prediction model based on artificial neural network is constructed for surface temperature simulation of nickel-metal hydride battery. The model is developed from a back-propagation network which is trained by Levenberg-Marquardt algorithm. Under each ambient temperature of 10 °C, 20 °C, 30 °C and 40 °C, an 8 Ah cylindrical Ni-MH battery is charged in the rate of 1 C, 3 C and 5 C to its SOC of 110% in order to provide data for the model training. Linear regression method is adopted to check the quality of the model training, as well as mean square error and absolute error. It is shown that the constructed model is of excellent training quality for the guarantee of prediction accuracy. The surface temperature of battery during charging is predicted under various ambient temperatures of 50 °C, 60 °C, 70 °C by the model. The results are validated in good agreement with experimental data. The value of battery surface temperature is calculated to exceed 90 °C under the ambient temperature of 60 °C if it is overcharged in 5 C, which might cause battery safety issues.
NASA Astrophysics Data System (ADS)
Martin, E. H.; Goniche, M.; Klepper, C. C.; Hillairet, J.; Isler, R. C.; Bottereau, C.; Colas, L.; Ekedahl, A.; Panayotis, S.; Pegourie, B.; Lotte, Ph; Colledani, G.; Caughman, J. B.; Harris, J. H.; Hillis, D. L.; Shannon, S. C.; Clairet, F.; Litaudon, X.
2015-06-01
Interaction of radio-frequency (RF) waves with the plasma in the near-field of a high-power wave launcher is now seen to be an important topic, both in understanding the channeling of these waves through the plasma boundary and in avoiding power losses in the edge. In a recent Letter, a direct non-intrusive measurement of a near antenna RF electric field in the range of lower hybrid (LH) frequencies (ELH) was announced (2013 Phys. Rev. Lett. 110 215005). This measurement was achieved through the fitting of Balmer series deuterium spectral lines utilizing a time dependent (dynamic) Stark effect model. In this article, the analysis of the spectral data is discussed in detail and applied to a larger range of measurements and the accuracy and limitations of the experimental technique are investigated. It was found through an analysis of numerous Tore Supra discharges that good quantitative agreement exists between the measured and full-wave modeled ELH when the launched power exceeds 0.5 MW. For low power the measurement becomes inaccurate utilizing the implemented passive spectroscopic technique because the spectral noise overwhelms the effect of the RF electric field on the line profile. Additionally, effects of the ponderomotive force are suspected at sufficiently high power.
Kang, Jian; Li, Xin; Jin, Rui; Ge, Yong; Wang, Jinfeng; Wang, Jianghao
2014-10-14
The eco-hydrological wireless sensor network (EHWSN) in the middle reaches of the Heihe River Basin in China is designed to capture the spatial and temporal variability and to estimate the ground truth for validating the remote sensing productions. However, there is no available prior information about a target variable. To meet both requirements, a hybrid model-based sampling method without any spatial autocorrelation assumptions is developed to optimize the distribution of EHWSN nodes based on geostatistics. This hybrid model incorporates two sub-criteria: one for the variogram modeling to represent the variability, another for improving the spatial prediction to evaluate remote sensing productions. The reasonability of the optimized EHWSN is validated from representativeness, the variogram modeling and the spatial accuracy through using 15 types of simulation fields generated with the unconditional geostatistical stochastic simulation. The sampling design shows good representativeness; variograms estimated by samples have less than 3% mean error relative to true variograms. Then, fields at multiple scales are predicted. As the scale increases, estimated fields have higher similarities to simulation fields at block sizes exceeding 240 m. The validations prove that this hybrid sampling method is effective for both objectives when we do not know the characteristics of an optimized variables.
SA36. Atypical Memory Structure Related to Recollective Ability
Greenland-White, Sarah; Niendam, Tara
2017-01-01
Abstract Background: People with schizophrenia have impaired recognition memory and disproportionate recollection rather than familiarity deficits. This pattern also occurs in individuals with early psychosis (EP) and those at clinical high risk (CHR; Ragland et al., 2016). Additionally, these groups show atypical relationships between different memory processes, with patients demonstrating a stronger reliance on familiarity to support recognition accuracy. However, it is unclear whether these group differences represent a compensatory “trade-off” in memory strategies, whereby patients adopt an overreliance on familiarity to compensate for impaired recollection. We examined data from the Relational and Item-Specific memory task (RiSE) in healthy control (HC), EP and CHR participants, and contrasted subgroups with and without prominent recollection impairments. Interrelations between these memory processes (accuracy, recollection, and familiarity) were examined with Structural Equation Modeling (SEM). Methods: A total of 181 individuals (57 HC, 101 EP, and 21 CHR) completed the RiSE. Measures of recognition accuracy, familiarity, and recollection were computed. We divided the patient group into those with poor recollection (overall d’ recognition accuracy < 1.5, n = 52) and those with good recollection (overall d’ recollection accuracy ≥ 1.5, n = 70). SEM was used to investigate the pattern of memory relationships between HC and patient groups as well as between patients with good versus bad recollection. Results: Recollection and familiarity were negatively correlated in the HC group (r = −.467, P < .01) and in the patient group, though more weakly (r = −.288,P < .05). Improved recollection was correlated with overall improvement in recognition accuracy for both the groups (HC r = .771, P < .01; r = .753, P < .01). Improved familiarity was associated with higher recognition accuracy in the patient group only (.361, P < .01). Moreover, patients with poor recollection showed a stronger association (Fisher’s Z = 2.58, P < .01) between familiarity performance and recognition accuracy (.718, P < .01) than patients with good recollection performance (.396, P < .01). Conclusion: Results suggest that patients may be overrelying on more intact familiarity processes to support recognition accuracy. This potential compensatory strategy is particularly marked in those patients with the worst recollection abilities. The finding that recognition accuracy remains impaired in both patient subgroups, however, reveals that this compensatory familiarity-based strategy is not fully successful. Further work is needed to understand how patients can be remediated for their consistently impaired recollection processes.
Darwish, Ibrahim A.; Amer, Sawsan M.; Abdine, Heba H.; Al-Rayes, Lama I.
2008-01-01
New simple spectrofluorimetric method with enhanced sensitivity has been developed and validated for the determination of the antidepressant paroxetine (PXT) in its dosage forms and plasma. The method was based on nucleophilic substitution reaction of PXT with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole in an alkaline medium (pH 8) to form a highly fluorescent derivative that was measured at 545 nm after excitation at 490 nm. The factors affecting the reaction was carefully studied and optimized. The kinetics of the reaction was investigated, and the reaction mechanism was presented. Under the optimized conditions, linear relationship with good correlation coefficient (0.9993) was found between the fluorescence intensity and PXT concentration in the range of 80–800 ng ml−1. The limits of detection and quantitation for the method were 25 and 77 ng ml−1, respectively. The precision of the method was satisfactory; the values of relative standard deviations did not exceed 3%. The proposed method was successfully applied to the determination of PXT in its pharmaceutical tablets with good accuracy; the recovery values were 100.2 ± 1.61%. The results obtained by the proposed method were comparable with those obtained by the official method. The proposed method is superior to the previously reported spectrofluorimetric method for determination of PXT in terms of its higher sensitivity and wider linear range. The high sensitivity of the method allowed its successful application to the analysis of PXT in spiked human plasma. The proposed method is practical and valuable for its routine application in quality control and clinical laboratories for analysis of PXT. PMID:19609398
Darwish, Ibrahim A; Khedr, Alaa S; Askal, Hassan F; Mohamed, Ramadan M
2006-01-01
Eight spectrophotometric methods for determination of ribavirin have been developed and validated. These methods were based on the oxidation of the drug by different inorganic oxidants: ceric ammonium sulfate, potassium permanganate, ammonium molybdate, ammonium metavanidate, chromium trioxide, potassium dichromate, potassium iodate, and potassium periodate. The oxidation reactions were performed in perchloric acid medium for ceric ammonium sulfate and in sulfuric acid medium for the other reagents. With ceric ammonium sulfate and potassium permanganate, the concentration of ribavirin in its samples was determined by measuring the decrease in the absorption intensity of the colored reagents at 315 and 525 nm, respectively. With the other reagents, the concentration of ribavirin was determined by measuring the intensity of the developed colored reaction products at the wavelengths of maximum absorbance: 675, 780, 595, 595, 475, and 475 nm for reactions with ammonium molybdate, ammonium metavanidate, chromium trioxide, potassium dichromate, potassium iodate, and potassium periodate, respectively. Different variables affecting the reaction conditions were carefully studied and optimized. Under the optimum conditions, linear relationships with good correlation coefficients (0.9984-0.9998) were found between the absorbance readings and the concentrations of ribavirin in the range of 4-1400 microg/mL. The molar absorptivities were correlated with the oxidation potential of the oxidants used. The precision of the methods were satisfactory; the values of relative standard deviation did not exceed 1.64%. The proposed methods were successfully applied to the analysis of ribavirin in pure drug material and capsules with good accuracy and precision; the recovery values were 99.2-101.2 +/- 0.48-1.30%. The results obtained using the proposed spectrophotometric methods were comparable with those obtained with the official method stated in the United States Pharmacopeia.
Koene, S; Timmermans, J; Weijers, G; de Laat, P; de Korte, C L; Smeitink, J A M; Janssen, M C H; Kapusta, L
2017-03-01
Cardiomyopathy is a common complication of mitochondrial disorders, associated with increased mortality. Two dimensional speckle tracking echocardiography (2DSTE) can be used to quantify myocardial deformation. Here, we aimed to determine the usefulness of 2DSTE in detecting and monitoring subtle changes in myocardial dysfunction in carriers of the 3243A>G mutation in mitochondrial DNA. In this retrospective pilot study, 30 symptomatic and asymptomatic carriers of the mitochondrial 3243A>G mutation of whom two subsequent echocardiograms were available were included. We measured longitudinal, circumferential and radial strain using 2DSTE. Results were compared to published reference values. Speckle tracking was feasible in 90 % of the patients for longitudinal strain. Circumferential and radial strain showed low face validity (low number of images with sufficient quality; suboptimal tracking) and were therefore rejected for further analysis. Global longitudinal strain showed good face validity, and was abnormal in 56-70 % (depending on reference values used) of the carriers (n = 27). Reproducibility was good (mean difference of 0.83 for inter- and 0.40 for intra-rater reproducibility; ICC 0.78 and 0.89, respectively). The difference between the first and the second measurement exceeded the measurement variance in 39 % of the cases (n = 23; feasibility of follow-up 77 %). Even in data collected as part of clinical care, two-dimensional strain echocardiography seems a feasible method to detect and monitor subtle changes in longitudinal myocardial deformation in adult carriers of the mitochondrial 3243A>G mutation. Based on our data and the reported accuracy of global longitudinal strain in other studies, we suggest the use of global longitudinal strain in a prospective follow-up or intervention study.
Suryawanshi, Vishwas D; Gore, Anil H; Dongare, Pravin R; Anbhule, Prashant V; Patil, Shivajirao R; Kolekar, Govind B
2013-10-01
An efficient fluorescent chemosensor Al(3+) receptor based on pyrimidine derivative,2-amino-6-hydroxy-4-(4-N,N-dimethylaminophenyl)-pyrimidine-5-carbonitrile (DMAB), has been synthesized by three-component condensation of aromatic aldehyde, ethyl cyanoacetate and guanidine hydrochloride in ethanol under alkaline medium. High selectivity and sensitivity of DMAB towards Aluminum ion (Al(3+)) in water: ethanol and acetate buffer at pH 4.0 makes it suitable to detect Al(3+) with steady-state UV-vis and fluorescence spectroscopy. Method shows good selectivity towards Al(3+) over other coexisting metal ions tested, viz. Fe(2+), Ni(2+), Cu(2+), Co(2+), Pb(2+), Sb(3+), Na(+), Ca(2+), Mg(2+), Zn(2+), Hg(2+), Ba(2+), Cd(2+) and K(+). A good linearity between the Stern-Volmer plots of F0/F versus concentration of Al(3+) was observed over the range from 10 to 60 μg mL(-1) with correlation coefficient of 0.991. The accuracy and reliability of the method were further confirmed by recovery studies via standard addition method with percent recoveries in the range of 101.03-103.44% and lowest detection limit (LOD=7.35 μg mL(-1)) for Al(3+) was established. This method may offer a new cost-effective, rapid, and simple key to the inspection of Al(3+) ions in water samples in the presence of a complex matrix and can be capable of evaluating the exceeding standard of Al(3+) in environmental water samples. The probable mechanism for fluorescence quenching was also discussed. Copyright © 2013 Elsevier B.V. All rights reserved.
SvSXP: a Strongylus vulgaris antigen with potential for prepatent diagnosis.
Andersen, Ulla V; Howe, Daniel K; Dangoudoubiyam, Sriveny; Toft, Nils; Reinemeyer, Craig R; Lyons, Eugene T; Olsen, Susanne N; Monrad, Jesper; Nejsum, Peter; Nielsen, Martin K
2013-04-04
Strongyle parasites are ubiquitous in grazing horses. Strongylus vulgaris, the most pathogenic of the large strongyles, is known for its extensive migration in the mesenteric arterial system. The lifecycle of S. vulgaris is characterised by a long prepatent period where the migrating larvae are virtually undetectable as there currently is no test available for diagnosing prepatent S. vulgaris infection. Presence of S. vulgaris larvae in the arterial system causes endarteritis and thrombosis with a risk of non-strangulating intestinal infarctions. Emergence of anthelmintic resistance among cyathostomins has led to recommendations of reduced treatment intensity by targeting horses that exceed a predetermined strongyle faecal egg count threshold. One study suggests an apparent increase in prevalence of S. vulgaris on farms where reduced anthelmintic treatment intensity has been implemented. These issues highlight the need for an accurate and reliable assay for diagnosing prepatent S. vulgaris infection. Immunoscreening of a larval S. vulgaris cDNA library using hyperimmune serum raised against S. vulgaris excretory/secretory antigens was performed to identify potential diagnostic antigens. Immunoreactive clones were sequenced, one potential antigen was characterised, expressed as a recombinant protein, initially evaluated by western blot (WB) analysis, the diagnostic potential of the IgG subclasses was evaluated by ELISA, and the diagnostic accuracy evaluated using serum from 102 horses with known S. vulgaris infection status. The clone expressing the potential antigen encoded a S. vulgaris SXP/RAL2 homologue. The recombinant protein, rSvSXP, was shown to be a potential diagnostic antigen by WB analysis, and a target of serum IgGa, IgG(T) and total IgG in naturally infected horses, with IgG(T) antibodies being the most reliable indicator of S. vulgaris infection in horses. Evaluation of diagnostic accuracy of the ELISA resulted in a sensitivity of 73.3%, a specificity of 81.0%, a diagnostic odds ratio of 11.69; a positive likelihood ratio (LR) of 3.85 and a negative LR was 0.33. The area under the ROC curve was 0.820. IgG(T) antibodies to recombinant SvSXP show potential for use as an antigen for prepatent diagnosis of migrating stages of S. vulgaris with moderate to good diagnostic accuracy.
Diagnostic accuracy for major depression in multiple sclerosis using self-report questionnaires.
Fischer, Anja; Fischer, Marcus; Nicholls, Robert A; Lau, Stephanie; Poettgen, Jana; Patas, Kostas; Heesen, Christoph; Gold, Stefan M
2015-09-01
Multiple sclerosis and major depressive disorder frequently co-occur but depression often remains undiagnosed in this population. Self-rated depression questionnaires are a good option where clinician-based standardized diagnostics are not feasible. However, there is a paucity of data on diagnostic accuracy of self-report measures for depression in multiple sclerosis (MS). Moreover, head-to-head comparisons of common questionnaires are largely lacking. This could be particularly relevant for high-risk patients with depressive symptoms. Here, we compare the diagnostic accuracy of the Beck Depression Inventory (BDI) and 30-item version of the Inventory of Depressive Symptomatology Self-Rated (IDS-SR30) for major depressive disorder (MSS) against diagnosis by a structured clinical interview. Patients reporting depressive symptoms completed the BDI, the IDS-SR30 and underwent diagnostic assessment (Mini International Neuropsychiatric Interview, M.I.N.I.). Receiver-Operating Characteristic analyses were performed, providing error estimates and false-positive/negative rates of suggested thresholds. Data from n = 31 MS patients were available. BDI and IDS-SR30 total score were significantly correlated (r = 0.82). The IDS-SR30total score, cognitive subscore, and BDI showed excellent to good accuracy (area under the curve (AUC) 0.86, 0.91, and 0.85, respectively). Both the IDS-SR30 and the BDI are useful to quantify depressive symptoms showing good sensitivity and specificity. The IDS-SR30 cognitive subscale may be useful as a screening tool and to quantify affective/cognitive depressive symptomatology.
25 CFR 141.49 - Usury prohibited.
Code of Federal Regulations, 2013 CFR
2013-04-01
... INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR FINANCIAL ACTIVITIES BUSINESS PRACTICES ON THE NAVAJO, HOPI... reservation business may take or receive money, goods, or other things of value for a loan or forbearance on a debt that exceeds in value the principal plus twenty-four percent (24 percent) per annum finance charge...
25 CFR 141.49 - Usury prohibited.
Code of Federal Regulations, 2011 CFR
2011-04-01
... INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR FINANCIAL ACTIVITIES BUSINESS PRACTICES ON THE NAVAJO, HOPI... reservation business may take or receive money, goods, or other things of value for a loan or forbearance on a debt that exceeds in value the principal plus twenty-four percent (24 percent) per annum finance charge...
25 CFR 141.49 - Usury prohibited.
Code of Federal Regulations, 2010 CFR
2010-04-01
... INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR FINANCIAL ACTIVITIES BUSINESS PRACTICES ON THE NAVAJO, HOPI... reservation business may take or receive money, goods, or other things of value for a loan or forbearance on a debt that exceeds in value the principal plus twenty-four percent (24 percent) per annum finance charge...
25 CFR 141.49 - Usury prohibited.
Code of Federal Regulations, 2014 CFR
2014-04-01
... INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR FINANCIAL ACTIVITIES BUSINESS PRACTICES ON THE NAVAJO, HOPI... reservation business may take or receive money, goods, or other things of value for a loan or forbearance on a debt that exceeds in value the principal plus twenty-four percent (24 percent) per annum finance charge...
25 CFR 141.49 - Usury prohibited.
Code of Federal Regulations, 2012 CFR
2012-04-01
... INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR FINANCIAL ACTIVITIES BUSINESS PRACTICES ON THE NAVAJO, HOPI... reservation business may take or receive money, goods, or other things of value for a loan or forbearance on a debt that exceeds in value the principal plus twenty-four percent (24 percent) per annum finance charge...
21 CFR 184.1139 - Ammonium hydroxide.
Code of Federal Regulations, 2014 CFR
2014-04-01
...-finishing agent as defined in § 170.3(o)(30) of this chapter; and as a boiler water additive complying with... manufacturing practice. The ingredient may also be used as a boiler water additive at levels not to exceed... limitation other than current good manufacturing practice. The affirmation of this ingredient as generally...
21 CFR 186.1374 - Iron oxides.
Code of Federal Regulations, 2011 CFR
2011-04-01
... food packaging. (2) The ingredient is used at levels not to exceed current good manufacturing practice... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Iron oxides. 186.1374 Section 186.1374 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN...
21 CFR 186.1300 - Ferric oxide.
Code of Federal Regulations, 2011 CFR
2011-04-01
... food packaging. (2) The ingredient is used at levels not to exceed current good manufacturing practice... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Ferric oxide. 186.1300 Section 186.1300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN...
21 CFR 186.1374 - Iron oxides.
Code of Federal Regulations, 2010 CFR
2010-04-01
... food packaging. (2) The ingredient is used at levels not to exceed current good manufacturing practice... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Iron oxides. 186.1374 Section 186.1374 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN...
21 CFR 186.1300 - Ferric oxide.
Code of Federal Regulations, 2010 CFR
2010-04-01
... food packaging. (2) The ingredient is used at levels not to exceed current good manufacturing practice... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ferric oxide. 186.1300 Section 186.1300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN...
21 CFR 186.1551 - Hydrogenated fish oil.
Code of Federal Regulations, 2011 CFR
2011-04-01
... used for dry food packaging. (d) The ingredient is used at levels not to exceed good manufacturing... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Hydrogenated fish oil. 186.1551 Section 186.1551 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD...
Code of Federal Regulations, 2013 CFR
2013-04-01
... weight of the tablet. (2) When aspartame is used in baked goods and baking mixes, the amount of the additive is not to exceed 0.5 percent by weight of ready-to-bake products or of finished formulations prior to baking. Generally recognized as safe (GRAS) ingredients or food additives approved for use in...
Code of Federal Regulations, 2010 CFR
2010-04-01
... weight of the tablet. (2) When aspartame is used in baked goods and baking mixes, the amount of the additive is not to exceed 0.5 percent by weight of ready-to-bake products or of finished formulations prior to baking. Generally recognized as safe (GRAS) ingredients or food additives approved for use in...
Code of Federal Regulations, 2012 CFR
2012-04-01
... weight of the tablet. (2) When aspartame is used in baked goods and baking mixes, the amount of the additive is not to exceed 0.5 percent by weight of ready-to-bake products or of finished formulations prior to baking. Generally recognized as safe (GRAS) ingredients or food additives approved for use in...
Code of Federal Regulations, 2011 CFR
2011-04-01
... weight of the tablet. (2) When aspartame is used in baked goods and baking mixes, the amount of the additive is not to exceed 0.5 percent by weight of ready-to-bake products or of finished formulations prior to baking. Generally recognized as safe (GRAS) ingredients or food additives approved for use in...
21 CFR 184.1622 - Potassium chloride.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Potassium chloride. 184.1622 Section 184.1622 Food... Specific Substances Affirmed as GRAS § 184.1622 Potassium chloride. (a) Potassium chloride (KCl, CAS Reg... levels not to exceed current good manufacturing practice. Potassium chloride may be used in infant...
21 CFR 184.1622 - Potassium chloride.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Potassium chloride. 184.1622 Section 184.1622 Food... Specific Substances Affirmed as GRAS § 184.1622 Potassium chloride. (a) Potassium chloride (KCl, CAS Reg... levels not to exceed current good manufacturing practice. Potassium chloride may be used in infant...
ERIC Educational Resources Information Center
Barlow, Dudley
2004-01-01
The Michigan Educational Assessment Program (MEAP) test scores for 2004 have been announced. The tests, administered to juniors, attempt to assess how well students perform in mathematics, reading, writing, science, and social studies. There is a good deal at stake here. For students, it means money: Any student who meets or exceeds the state's…
Graduation Certification--Too Late to Graduate!
ERIC Educational Resources Information Center
Doman, Mark S.
2017-01-01
Oakland University (OU) in Rochester, Michigan, was experiencing growing pains. The good news was that OU had experienced 23 years of continuous enrollment growth, with student enrollment exceeding 20,000 in 2015 for the first time ever. The downside was that various administrative processes throughout the university were straining to keep up. One…
21 CFR 186.1374 - Iron oxides.
Code of Federal Regulations, 2012 CFR
2012-04-01
... food packaging. (2) The ingredient is used at levels not to exceed current good manufacturing practice... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Iron oxides. 186.1374 Section 186.1374 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN...
21 CFR 186.1300 - Ferric oxide.
Code of Federal Regulations, 2013 CFR
2013-04-01
... food packaging. (2) The ingredient is used at levels not to exceed current good manufacturing practice... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Ferric oxide. 186.1300 Section 186.1300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN...
21 CFR 186.1374 - Iron oxides.
Code of Federal Regulations, 2013 CFR
2013-04-01
... food packaging. (2) The ingredient is used at levels not to exceed current good manufacturing practice... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Iron oxides. 186.1374 Section 186.1374 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN...
21 CFR 186.1316 - Formic acid.
Code of Federal Regulations, 2014 CFR
2014-04-01
... used for food packaging. (c) The ingredient is used at levels not to exceed good manufacturing practice... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Formic acid. 186.1316 Section 186.1316 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) INDIRECT FOOD...
21 CFR 186.1300 - Ferric oxide.
Code of Federal Regulations, 2012 CFR
2012-04-01
... food packaging. (2) The ingredient is used at levels not to exceed current good manufacturing practice... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Ferric oxide. 186.1300 Section 186.1300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN...
7 CFR 2200.11 - Government-wide debarment and suspension (nonprocurement).
Code of Federal Regulations, 2010 CFR
2010-01-01
... of type, expected to equal or exceed the Federal procurement small purchase threshold fixed at 10 U.S... who is debarred or suspended shall be excluded from Federal financial and nonfinancial assistance and... than a procurement contract for goods or services, regardless of type, under a primary covered...
Code of Federal Regulations, 2010 CFR
2010-07-01
... following factors and other factors deemed relevant by the Director: Length of season; peakloads; average.... Such rates and charges may not exceed the market rates and charges for comparable facilities, goods, and services, after taking these factors into consideration. ...
On distributed wavefront reconstruction for large-scale adaptive optics systems.
de Visser, Cornelis C; Brunner, Elisabeth; Verhaegen, Michel
2016-05-01
The distributed-spline-based aberration reconstruction (D-SABRE) method is proposed for distributed wavefront reconstruction with applications to large-scale adaptive optics systems. D-SABRE decomposes the wavefront sensor domain into any number of partitions and solves a local wavefront reconstruction problem on each partition using multivariate splines. D-SABRE accuracy is within 1% of a global approach with a speedup that scales quadratically with the number of partitions. The D-SABRE is compared to the distributed cumulative reconstruction (CuRe-D) method in open-loop and closed-loop simulations using the YAO adaptive optics simulation tool. D-SABRE accuracy exceeds CuRe-D for low levels of decomposition, and D-SABRE proved to be more robust to variations in the loop gain.
High-harmonic spectroscopy of ultrafast many-body dynamics in strongly correlated systems
NASA Astrophysics Data System (ADS)
Silva, R. E. F.; Blinov, Igor V.; Rubtsov, Alexey N.; Smirnova, O.; Ivanov, M.
2018-05-01
We bring together two topics that, until now, have been the focus of intense but non-overlapping research efforts. The first concerns high-harmonic generation in solids, which occurs when an intense light field excites a highly non-equilibrium electronic response in a semiconductor or a dielectric. The second concerns many-body dynamics in strongly correlated systems such as the Mott insulator. We show that high-harmonic generation can be used to time-resolve ultrafast many-body dynamics associated with an optically driven phase transition, with accuracy far exceeding one cycle of the driving light field. Our work paves the way for time-resolving highly non-equilibrium many-body dynamics in strongly correlated systems, with few femtosecond accuracy.
Electroencephalography Predicts Poor and Good Outcomes After Cardiac Arrest: A Two-Center Study.
Rossetti, Andrea O; Tovar Quiroga, Diego F; Juan, Elsa; Novy, Jan; White, Roger D; Ben-Hamouda, Nawfel; Britton, Jeffrey W; Oddo, Mauro; Rabinstein, Alejandro A
2017-07-01
The prognostic role of electroencephalography during and after targeted temperature management in postcardiac arrest patients, relatively to other predictors, is incompletely known. We assessed performances of electroencephalography during and after targeted temperature management toward good and poor outcomes, along with other recognized predictors. Cohort study (April 2009 to March 2016). Two academic hospitals (Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland; Mayo Clinic, Rochester, MN). Consecutive comatose adults admitted after cardiac arrest, identified through prospective registries. All patients were managed with targeted temperature management, receiving prespecified standardized clinical, neurophysiologic (particularly, electroencephalography during and after targeted temperature management), and biochemical evaluations. We assessed electroencephalography variables (reactivity, continuity, epileptiform features, and prespecified "benign" or "highly malignant" patterns based on the American Clinical Neurophysiology Society nomenclature) and other clinical, neurophysiologic (somatosensory-evoked potential), and biochemical prognosticators. Good outcome (Cerebral Performance Categories 1 and 2) and mortality predictions at 3 months were calculated. Among 357 patients, early electroencephalography reactivity and continuity and flexor or better motor reaction had greater than 70% positive predictive value for good outcome; reactivity (80.4%; 95% CI, 75.9-84.4%) and motor response (80.1%; 95% CI, 75.6-84.1%) had highest accuracy. Early benign electroencephalography heralded good outcome in 86.2% (95% CI, 79.8-91.1%). False positive rates for mortality were less than 5% for epileptiform or nonreactive early electroencephalography, nonreactive late electroencephalography, absent somatosensory-evoked potential, absent pupillary or corneal reflexes, presence of myoclonus, and neuron-specific enolase greater than 75 µg/L; accuracy was highest for early electroencephalography reactivity (86.6%; 95% CI, 82.6-90.0). Early highly malignant electroencephalography had an false positive rate of 1.5% with accuracy of 85.7% (95% CI, 81.7-89.2%). This study provides class III evidence that electroencephalography reactivity predicts both poor and good outcomes, and motor reaction good outcome after cardiac arrest. Electroencephalography reactivity seems to be the best discriminator between good and poor outcomes. Standardized electroencephalography interpretation seems to predict both conditions during and after targeted temperature management.
NASA Technical Reports Server (NTRS)
Lemoine, F. G.; Zelensky, N. P.; Luthcke, S. B.; Rowlands, D. D.; Beckley, B. D.; Klosko, S. M.
2006-01-01
Launched in the summer of 1992, TOPEX/POSEIDON (T/P) was a joint mission between NASA and the Centre National d Etudes Spatiales (CNES), the French Space Agency, to make precise radar altimeter measurements of the ocean surface. After the remarkably successful 13-years of mapping the ocean surface T/P lost its ability to maneuver and was de-commissioned January 2006. T/P revolutionized the study of the Earth s oceans by vastly exceeding pre-launch estimates of surface height accuracy recoverable from radar altimeter measurements. The precision orbit lies at the heart of the altimeter measurement providing the reference frame from which the radar altimeter measurements are made. The expected quality of orbit knowledge had limited the measurement accuracy expectations of past altimeter missions, and still remains a major component in the error budget of all altimeter missions. This paper describes critical improvements made to the T/P orbit time series over the 13-years of precise orbit determination (POD) provided by the GSFC Space Geodesy Laboratory. The POD improvements from the pre-launch T/P expectation of radial orbit accuracy and Mission requirement of 13-cm to an expected accuracy of about 1.5-cm with today s latest orbits will be discussed. The latest orbits with 1.5 cm RMS radial accuracy represent a significant improvement to the 2.0-cm accuracy orbits currently available on the T/P Geophysical Data Record (GDR) altimeter product.
Effect of provider volume on the accuracy of hospital report cards: a Monte Carlo study.
Austin, Peter C; Reeves, Mathew J
2014-03-01
Hospital report cards, in which outcomes after the provision of medical or surgical care are compared across healthcare providers, are being published with increasing frequency. However, the accuracy of such comparisons is controversial, especially when case volumes are small. The objective was to determine the relationship between hospital case volume and the accuracy of hospital report cards. Monte Carlo simulations were used to examine the influence of hospital case volume on the accuracy of hospital report cards in a setting in which true hospital performance was known with certainty, and perfect risk-adjustment was feasible. The parameters used to generate the simulated data sets were obtained from empirical analyses of data on patients hospitalized with acute myocardial infarction in Ontario, Canada, in which the overall 30-day mortality rate was 11.1%. We found that provider volume had a strong effect on the accuracy of hospital report cards. However, provider volume had to be >300 before ≥70% of hospitals were correctly classified. Furthermore, hospital volume had to be >1000 before ≥80% of hospitals were correctly classified. Producers and users of hospital report cards need to be aware that, even when perfect risk adjustment is possible, the accuracy of hospital report cards is, at best, modest for small to medium-sized case loads (i.e., 100-300). Hospital report cards displayed high degrees of accuracy only when provider volumes exceeded the typical annual hospital case load for many cardiovascular conditions and procedures.
Investigation on the Practicality of Developing Reduced Thermal Models
NASA Technical Reports Server (NTRS)
Lombardi, Giancarlo; Yang, Kan
2015-01-01
Throughout the spacecraft design and development process, detailed instrument thermal models are created to simulate their on-orbit behavior and to ensure that they do not exceed any thermal limits. These detailed models, while generating highly accurate predictions, can sometimes lead to long simulation run times, especially when integrated with a spacecraft observatory model. Therefore, reduced models containing less detail are typically produced in tandem with the detailed models so that results may be more readily available, albeit less accurate. In the current study, both reduced and detailed instrument models are integrated with their associated spacecraft bus models to examine the impact of instrument model reduction on run time and accuracy. Preexisting instrument bus thermal model pairs from several projects were used to determine trends between detailed and reduced thermal models; namely, the Mirror Optical Bench (MOB) on the Gravity and Extreme Magnetism Small Explorer (GEMS) spacecraft, Advanced Topography Laser Altimeter System (ATLAS) on the Ice, Cloud, and Elevation Satellite 2 (ICESat-2), and the Neutral Mass Spectrometer (NMS) on the Lunar Atmosphere and Dust Environment Explorer (LADEE). Hot and cold cases were run for each model to capture the behavior of the models at both thermal extremes. It was found that, though decreasing the number of nodes from a detailed to reduced model brought about a reduction in the run-time, a large time savings was not observed, nor was it a linear relationship between the percentage of nodes reduced and time saved. However, significant losses in accuracy were observed with greater model reduction. It was found that while reduced models are useful in decreasing run time, there exists a threshold of reduction where, once exceeded, the loss in accuracy outweighs the benefit from reduced model runtime.
Weber, Marc; Teeling, Hanno; Huang, Sixing; Waldmann, Jost; Kassabgy, Mariette; Fuchs, Bernhard M; Klindworth, Anna; Klockow, Christine; Wichels, Antje; Gerdts, Gunnar; Amann, Rudolf; Glöckner, Frank Oliver
2011-01-01
Next-generation sequencing (NGS) technologies have enabled the application of broad-scale sequencing in microbial biodiversity and metagenome studies. Biodiversity is usually targeted by classifying 16S ribosomal RNA genes, while metagenomic approaches target metabolic genes. However, both approaches remain isolated, as long as the taxonomic and functional information cannot be interrelated. Techniques like self-organizing maps (SOMs) have been applied to cluster metagenomes into taxon-specific bins in order to link biodiversity with functions, but have not been applied to broad-scale NGS-based metagenomics yet. Here, we provide a novel implementation, demonstrate its potential and practicability, and provide a web-based service for public usage. Evaluation with published data sets mimicking varyingly complex habitats resulted into classification specificities and sensitivities of close to 100% to above 90% from phylum to genus level for assemblies exceeding 8 kb for low and medium complexity data. When applied to five real-world metagenomes of medium complexity from direct pyrosequencing of marine subsurface waters, classifications of assemblies above 2.5 kb were in good agreement with fluorescence in situ hybridizations, indicating that biodiversity was mostly retained within the metagenomes, and confirming high classification specificities. This was validated by two protein-based classifications (PBCs) methods. SOMs were able to retrieve the relevant taxa down to the genus level, while surpassing PBCs in resolution. In order to make the approach accessible to a broad audience, we implemented a feature-rich web-based SOM application named TaxSOM, which is freely available at http://www.megx.net/toolbox/taxsom. TaxSOM can classify reads or assemblies exceeding 2.5 kb with high accuracy and thus assists in linking biodiversity and functions in metagenome studies, which is a precondition to study microbial ecology in a holistic fashion. PMID:21160538
Plasma Modification of Graphite Fibers and Its Effect on Composite Properties.
1983-08-01
liquids have been difficult to measure with adequate accuracy. As a result, critical surface energy data are not readily available. A flotation method...tension of the fiber surface. However, the fiber density must always exceed the density of the flotation liquid. Although this is a very useful...technioue, it is inanplicable to graphite fiber due to its irregular surface structure, small filament diameter and small difference in density with flotation
Comparison of Measured and Calculated Stresses in Built-up Beams
NASA Technical Reports Server (NTRS)
Levin, L Ross; Nelson, David H
1946-01-01
Web stresses and flange stresses were measured in three built-up beams: one of constant depth with flanges of constant cross-section, one linearly tapered in depth with flanges of constant cross section, and one linearly tapered in depth with tapered flanges. The measured stresses were compared with the calculated stresses obtained by the methods outlined in order to determine the degree of accuracy that may be expected from the stress analysis formulas. These comparisons indicated that the average measured stresses for all points in the central section of the beams did not exceed the average calculated stresses by more than 5 percent. It also indicated that the difference between average measured flange stresses and average calculated flange stresses on the net area and a fully effective web did not exceed 6.1 percent.
ERIC Educational Resources Information Center
Cockburn, Stewart
1969-01-01
The basic requirements of all good prose are clarity, accuracy, brevity, and simplicity. Especially in public prose--in which the meaning is the crux of the article or speech--concise, vigorous English demands a minimum of adjectives, a maximum use of the active voice, nouns carefully chosen, a logical argument with no labored or obscure points,…
NASA Astrophysics Data System (ADS)
Utegulov, B. B.
2018-02-01
In the work the study of the developed method was carried out for reliability by analyzing the error in indirect determination of the insulation parameters in an asymmetric network with an isolated neutral voltage above 1000 V. The conducted studies of the random relative mean square errors show that the accuracy of indirect measurements in the developed method can be effectively regulated not only by selecting a capacitive additional conductivity, which are connected between phases of the electrical network and the ground, but also by the selection of measuring instruments according to the accuracy class. When choosing meters with accuracy class of 0.5 with the correct selection of capacitive additional conductivity that are connected between the phases of the electrical network and the ground, the errors in measuring the insulation parameters will not exceed 10%.
Narrative Skills, Gender, Culture, and Children's Long-Term Memory Accuracy of a Staged Event
ERIC Educational Resources Information Center
Klemfuss, J. Zoe; Wang, Qi
2017-01-01
This study examined the extent to which school-aged children's general narrative skills provide cognitive benefits for accurate remembering or enable good storytelling that undermines memory accuracy. European American and Chinese American 6-year-old boys and girls (N = 114) experienced a staged event in the laboratory and were asked to tell a…
Good Practices for Learning to Recognize Actions Using FV and VLAD.
Wu, Jianxin; Zhang, Yu; Lin, Weiyao
2016-12-01
High dimensional representations such as Fisher vectors (FV) and vectors of locally aggregated descriptors (VLAD) have shown state-of-the-art accuracy for action recognition in videos. The high dimensionality, on the other hand, also causes computational difficulties when scaling up to large-scale video data. This paper makes three lines of contributions to learning to recognize actions using high dimensional representations. First, we reviewed several existing techniques that improve upon FV or VLAD in image classification, and performed extensive empirical evaluations to assess their applicability for action recognition. Our analyses of these empirical results show that normality and bimodality are essential to achieve high accuracy. Second, we proposed a new pooling strategy for VLAD and three simple, efficient, and effective transformations for both FV and VLAD. Both proposed methods have shown higher accuracy than the original FV/VLAD method in extensive evaluations. Third, we proposed and evaluated new feature selection and compression methods for the FV and VLAD representations. This strategy uses only 4% of the storage of the original representation, but achieves comparable or even higher accuracy. Based on these contributions, we recommend a set of good practices for action recognition in videos for practitioners in this field.
Figueroa, José; Guarachi, Juan Pablo; Matas, José; Arnander, Magnus; Orrego, Mario
2016-04-01
Computed tomography (CT) is widely used to assess component rotation in patients with poor results after total knee arthroplasty (TKA). The purpose of this study was to simultaneously determine the accuracy and reliability of CT in measuring TKA component rotation. TKA components were implanted in dry-bone models and assigned to two groups. The first group (n = 7) had variable femoral component rotations, and the second group (n = 6) had variable tibial tray rotations. CT images were then used to assess component rotation. Accuracy of CT rotational assessment was determined by mean difference, in degrees, between implanted component rotation and CT-measured rotation. Intraclass correlation coefficient (ICC) was applied to determine intra-observer and inter-observer reliability. Femoral component accuracy showed a mean difference of 2.5° and the tibial tray a mean difference of 3.2°. There was good intra- and inter-observer reliability for both components, with a femoral ICC of 0.8 and 0.76, and tibial ICC of 0.68 and 0.65, respectively. CT rotational assessment accuracy can differ from true component rotation by approximately 3° for each component. It does, however, have good inter- and intra-observer reliability.
29 CFR 2700.70 - Petitions for discretionary review.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., petitions for discretionary review shall not exceed 35 pages. Except for good cause shown, no assignment of... 29 Labor 9 2010-07-01 2010-07-01 false Petitions for discretionary review. 2700.70 Section 2700.70... PROCEDURAL RULES Review by the Commission § 2700.70 Petitions for discretionary review. (a) Procedure. Any...
Hybrid poplar cultivars for maximizing phytomass production on gold mine tailings in the Black Hills
Ardell J. Bjugstad
1987-01-01
Twenty-six hybrid poplar clones were planted as cuttings on a gold mine tailings in the Black Hills. Four exhibited very good survival and growth. Other clones had relatively high (exceeding 50 percent) survival but slow growth (below 60 cm) over a 5-year period.
46 CFR 31.10-18 - Firefighting equipment: General-TB/ALL.
Code of Federal Regulations, 2013 CFR
2013-10-01
... extinguishing agent is needed. Carbon dioxide Weigh cylinders. Recharge if weight loss exceeds 10 percent of... ascertain that the system is in good operating condition. For carbon dioxide or clean agent systems as... be tested with at least 50 pounds per square inch of air pressure or by blowing steam through the...
46 CFR 31.10-18 - Firefighting equipment: General-TB/ALL.
Code of Federal Regulations, 2014 CFR
2014-10-01
... extinguishing agent is needed. Carbon dioxide Weigh cylinders. Recharge if weight loss exceeds 10 percent of... ascertain that the system is in good operating condition. For carbon dioxide or clean agent systems as... be tested with at least 50 pounds per square inch of air pressure or by blowing steam through the...
21 CFR 186.1316 - Formic acid.
Code of Federal Regulations, 2011 CFR
2011-04-01
... paper and paperboard used for food packaging. (c) The ingredient is used at levels not to exceed good... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Formic acid. 186.1316 Section 186.1316 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN...
21 CFR 186.1316 - Formic acid.
Code of Federal Regulations, 2010 CFR
2010-04-01
... paper and paperboard used for food packaging. (c) The ingredient is used at levels not to exceed good... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Formic acid. 186.1316 Section 186.1316 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN...
43 CFR 27.5 - Equal opportunity terms.
Code of Federal Regulations, 2010 CFR
2010-10-01
... contract will not exceed $10,000). (2) Recipient will make every good faith effort to secure the compliance... Public Law 93-153. (iv) Contractor's noncompliance with the nondiscrimination clauses of this contract or... UNDER TITLE II OF PUBLIC LAW 93-153 § 27.5 Equal opportunity terms. Each permit, right-of-way, public...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-14
... losses in India's transmission and distribution sector exceed 30%, which ranks among the highest rates of... Sri Lanka boost their infrastructure and building requirements. Target subsectors holding high.... The availability of electricity, fresh water, long coastline, backwaters, good banking facilities...
Ecosystems, their properties, goods, and services
Andreas Fischlin; G.F. Midgley; Jeff Price; Rik Leemans; Brij Gopal; Carol Turley; Mark Rounsevell; Pauline Dube; Juan Tarazona; Andrei Velichko
2007-01-01
During the course of this century the resilience of many ecosystems (their ability to adapt naturally) is likely to be exceeded by an unprecedented combination of change in climate, associated disturbances (e.g., flooding, drought, wildfire, insects, ocean acidification) and in other global change drivers (especially land-use change, pollution, and over-exploitation of...
40 CFR 266.107 - Standards to control hydrogen chloride (HCl) and chlorine gas (Cl2) emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Industrial Furnaces § 266.107 Standards to control hydrogen chloride (HCl) and chlorine gas (Cl2) emissions... streams, including hazardous waste, fuels, and industrial furnace feed stocks shall not exceed the levels...: terrain-adjusted effective stack height, good engineering practice stack height, terrain type, land use...
40 CFR 266.107 - Standards to control hydrogen chloride (HCl) and chlorine gas (Cl2) emissions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Industrial Furnaces § 266.107 Standards to control hydrogen chloride (HCl) and chlorine gas (Cl2) emissions... streams, including hazardous waste, fuels, and industrial furnace feed stocks shall not exceed the levels...: terrain-adjusted effective stack height, good engineering practice stack height, terrain type, land use...
40 CFR 266.107 - Standards to control hydrogen chloride (HCl) and chlorine gas (Cl2) emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Industrial Furnaces § 266.107 Standards to control hydrogen chloride (HCl) and chlorine gas (Cl2) emissions... streams, including hazardous waste, fuels, and industrial furnace feed stocks shall not exceed the levels...: terrain-adjusted effective stack height, good engineering practice stack height, terrain type, land use...
40 CFR 266.107 - Standards to control hydrogen chloride (HCl) and chlorine gas (Cl2) emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Industrial Furnaces § 266.107 Standards to control hydrogen chloride (HCl) and chlorine gas (Cl2) emissions... streams, including hazardous waste, fuels, and industrial furnace feed stocks shall not exceed the levels...: terrain-adjusted effective stack height, good engineering practice stack height, terrain type, land use...
40 CFR 266.107 - Standards to control hydrogen chloride (HCl) and chlorine gas (Cl2) emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Industrial Furnaces § 266.107 Standards to control hydrogen chloride (HCl) and chlorine gas (Cl2) emissions... streams, including hazardous waste, fuels, and industrial furnace feed stocks shall not exceed the levels...: terrain-adjusted effective stack height, good engineering practice stack height, terrain type, land use...
21 CFR 186.1316 - Formic acid.
Code of Federal Regulations, 2012 CFR
2012-04-01
... paper and paperboard used for food packaging. (c) The ingredient is used at levels not to exceed good... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Formic acid. 186.1316 Section 186.1316 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN...
21 CFR 186.1316 - Formic acid.
Code of Federal Regulations, 2013 CFR
2013-04-01
... paper and paperboard used for food packaging. (c) The ingredient is used at levels not to exceed good... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Formic acid. 186.1316 Section 186.1316 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN...
Code of Federal Regulations, 2013 CFR
2013-01-01
... million (as adjusted) because it will exceed the next higher reporting threshold (see §§ 801.1(h... minus $1 million. In this example, since “A” is able in good faith to reasonably estimate the... 16 Commercial Practices 1 2013-01-01 2013-01-01 false Filing fee. 803.9 Section 803.9 Commercial...
Code of Federal Regulations, 2012 CFR
2012-01-01
... million (as adjusted) because it will exceed the next higher reporting threshold (see §§ 801.1(h... minus $1 million. In this example, since “A” is able in good faith to reasonably estimate the... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Filing fee. 803.9 Section 803.9 Commercial...
Code of Federal Regulations, 2011 CFR
2011-01-01
... million (as adjusted) because it will exceed the next higher reporting threshold (see §§ 801.1(h... minus $1 million. In this example, since “A” is able in good faith to reasonably estimate the... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Filing fee. 803.9 Section 803.9 Commercial...
21 CFR 172.878 - White mineral oil.
Code of Federal Regulations, 2010 CFR
2010-04-01
... yeast contamination during fermentation In an amount not to exceed good manufacturing practice. 4. As a... 21 Food and Drugs 3 2010-04-01 2009-04-01 true White mineral oil. 172.878 Section 172.878 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN...
Applied chemical ecology of the mountain pine beetle
Robert A. Progar; Nancy Gillette; Christopher J. Fettig; Kathryn Hrinkevich
2014-01-01
Mountain pine beetle, Dendroctonus ponderosae Hopkins, is a primary agent of forest disturbance in western North America. Episodic outbreaks occur at the convergence of favorable forest age and size class structure and climate patterns. Recent outbreaks have exceeded the historic range of variability of D. ponderosae-caused tree mortality affecting ecosystem goods and...
Violence Prevention Strategies of Inner-City Student Experts.
ERIC Educational Resources Information Center
Skovholt, Thomas; Cognetta, Phillip; Ye, Gretchen; King, Lolita
1997-01-01
Reports on violence prevention in an inner-city middle school. Interviews of students, deemed by peers and teachers as good at managing conflict, revealed eight themes. For example, student experts inoculated themselves in attitude to avoid violence; de-escalated situations when provoked; and believed the cost of fighting exceeds the reward. (RJM)
Gärtner, Fania R; de Miranda, Esteriek; Rijnders, Marlies E; Freeman, Liv M; Middeldorp, Johanna M; Bloemenkamp, Kitty W M; Stiggelbout, Anne M; van den Akker-van Marle, M Elske
2015-10-01
To validate the Labor and Delivery Index (LADY-X), a new delivery-specific utility measure. In a test-retest design, women were surveyed online, 6 to 8 weeks postpartum and again 1 to 2 weeks later. For reliability testing, we assessed the standard error of measurement (S.E.M.) and the intraclass correlation coefficient (ICC). For construct validity, we tested hypotheses on the association with comparison instruments (Mackey Childbirth Satisfaction Rating Scale and Wijma Delivery Experience Questionnaire), both on domain and total score levels. We assessed known-group differences using eight obstetrical indicators: method and place of birth, induction, transfer, control over pain medication, complications concerning mother and child, and experienced control. The questionnaire was completed by 308 women, 257 (83%) completed the retest. The distribution of LADY-X scores was skewed. The reliability was good, as the ICC exceeded 0.80 and the S.E.M. was 0.76. Requirements for good construct validity were fulfilled: all hypotheses for convergent and divergent validity were confirmed, and six of eight hypotheses for known-group differences were confirmed as all differences were statistically significant (P-values: <0.001-0.023), but for two tests, difference scores did not exceed the S.E.M. The LADY-X demonstrates good reliability and construct validity. Despite its skewed distribution, the LADY-X can discriminate between groups. With the preference weights available, the LADY-X might fulfill the need for a utility measure for cost-effectiveness studies for perinatal care interventions. Copyright © 2015 Elsevier Inc. All rights reserved.
Genotyping by sequencing for genomic prediction in a soybean breeding population.
Jarquín, Diego; Kocak, Kyle; Posadas, Luis; Hyma, Katie; Jedlicka, Joseph; Graef, George; Lorenz, Aaron
2014-08-29
Advances in genotyping technology, such as genotyping by sequencing (GBS), are making genomic prediction more attractive to reduce breeding cycle times and costs associated with phenotyping. Genomic prediction and selection has been studied in several crop species, but no reports exist in soybean. The objectives of this study were (i) evaluate prospects for genomic selection using GBS in a typical soybean breeding program and (ii) evaluate the effect of GBS marker selection and imputation on genomic prediction accuracy. To achieve these objectives, a set of soybean lines sampled from the University of Nebraska Soybean Breeding Program were genotyped using GBS and evaluated for yield and other agronomic traits at multiple Nebraska locations. Genotyping by sequencing scored 16,502 single nucleotide polymorphisms (SNPs) with minor-allele frequency (MAF) > 0.05 and percentage of missing values ≤ 5% on 301 elite soybean breeding lines. When SNPs with up to 80% missing values were included, 52,349 SNPs were scored. Prediction accuracy for grain yield, assessed using cross validation, was estimated to be 0.64, indicating good potential for using genomic selection for grain yield in soybean. Filtering SNPs based on missing data percentage had little to no effect on prediction accuracy, especially when random forest imputation was used to impute missing values. The highest accuracies were observed when random forest imputation was used on all SNPs, but differences were not significant. A standard additive G-BLUP model was robust; modeling additive-by-additive epistasis did not provide any improvement in prediction accuracy. The effect of training population size on accuracy began to plateau around 100, but accuracy steadily climbed until the largest possible size was used in this analysis. Including only SNPs with MAF > 0.30 provided higher accuracies when training populations were smaller. Using GBS for genomic prediction in soybean holds good potential to expedite genetic gain. Our results suggest that standard additive G-BLUP models can be used on unfiltered, imputed GBS data without loss in accuracy.
Measurement system with high accuracy for laser beam quality.
Ke, Yi; Zeng, Ciling; Xie, Peiyuan; Jiang, Qingshan; Liang, Ke; Yang, Zhenyu; Zhao, Ming
2015-05-20
Presently, most of the laser beam quality measurement system collimates the optical path manually with low efficiency and low repeatability. To solve these problems, this paper proposed a new collimated method to improve the reliability and accuracy of the measurement results. The system accuracy controlled the position of the mirror to change laser beam propagation direction, which can realize the beam perpendicularly incident to the photosurface of camera. The experiment results show that the proposed system has good repeatability and the measuring deviation of M2 factor is less than 0.6%.
Theoretical study of surface plasmon resonance sensors based on 2D bimetallic alloy grating
NASA Astrophysics Data System (ADS)
Dhibi, Abdelhak; Khemiri, Mehdi; Oumezzine, Mohamed
2016-11-01
A surface plasmon resonance (SPR) sensor based on 2D alloy grating with a high performance is proposed. The grating consists of homogeneous alloys of formula MxAg1-x, where M is gold, copper, platinum and palladium. Compared to the SPR sensors based a pure metal, the sensor based on angular interrogation with silver exhibits a sharper (i.e. larger depth-to-width ratio) reflectivity dip, which provides a big detection accuracy, whereas the sensor based on gold exhibits the broadest dips and the highest sensitivity. The detection accuracy of SPR sensor based a metal alloy is enhanced by the increase of silver composition. In addition, the composition of silver which is around 0.8 improves the sensitivity and the quality of SPR sensor of pure metal. Numerical simulations based on rigorous coupled wave analysis (RCWA) show that the sensor based on a metal alloy not only has a high sensitivity and a high detection accuracy, but also exhibits a good linearity and a good quality.
Diagnostic accuracy for major depression in multiple sclerosis using self-report questionnaires
Fischer, Anja; Fischer, Marcus; Nicholls, Robert A; Lau, Stephanie; Poettgen, Jana; Patas, Kostas; Heesen, Christoph; Gold, Stefan M
2015-01-01
Objective Multiple sclerosis and major depressive disorder frequently co-occur but depression often remains undiagnosed in this population. Self-rated depression questionnaires are a good option where clinician-based standardized diagnostics are not feasible. However, there is a paucity of data on diagnostic accuracy of self-report measures for depression in multiple sclerosis (MS). Moreover, head-to-head comparisons of common questionnaires are largely lacking. This could be particularly relevant for high-risk patients with depressive symptoms. Here, we compare the diagnostic accuracy of the Beck Depression Inventory (BDI) and 30-item version of the Inventory of Depressive Symptomatology Self-Rated (IDS-SR30) for major depressive disorder (MSS) against diagnosis by a structured clinical interview. Methods Patients reporting depressive symptoms completed the BDI, the IDS-SR30 and underwent diagnostic assessment (Mini International Neuropsychiatric Interview, M.I.N.I.). Receiver-Operating Characteristic analyses were performed, providing error estimates and false-positive/negative rates of suggested thresholds. Results Data from n = 31 MS patients were available. BDI and IDS-SR30 total score were significantly correlated (r = 0.82). The IDS-SR30total score, cognitive subscore, and BDI showed excellent to good accuracy (area under the curve (AUC) 0.86, 0.91, and 0.85, respectively). Conclusion Both the IDS-SR30 and the BDI are useful to quantify depressive symptoms showing good sensitivity and specificity. The IDS-SR30 cognitive subscale may be useful as a screening tool and to quantify affective/cognitive depressive symptomatology. PMID:26445703
Ensemble coding remains accurate under object and spatial visual working memory load.
Epstein, Michael L; Emmanouil, Tatiana A
2017-10-01
A number of studies have provided evidence that the visual system statistically summarizes large amounts of information that would exceed the limitations of attention and working memory (ensemble coding). However the necessity of working memory resources for ensemble coding has not yet been tested directly. In the current study, we used a dual task design to test the effect of object and spatial visual working memory load on size averaging accuracy. In Experiment 1, we tested participants' accuracy in comparing the mean size of two sets under various levels of object visual working memory load. Although the accuracy of average size judgments depended on the difference in mean size between the two sets, we found no effect of working memory load. In Experiment 2, we tested the same average size judgment while participants were under spatial visual working memory load, again finding no effect of load on averaging accuracy. Overall our results reveal that ensemble coding can proceed unimpeded and highly accurately under both object and spatial visual working memory load, providing further evidence that ensemble coding reflects a basic perceptual process distinct from that of individual object processing.
Cosmic Origins Spectrograph : Target Acquisition Performance and Updated Guidelines
NASA Astrophysics Data System (ADS)
Penton, Steven V.; Keyes, C.; Osterman, S.; Sahnow, D.; Soderblom, D.; COS IDT Team; STScI COS Team
2010-01-01
The Cosmic Origins Spectrograph (COS) is a slit-less spectrograph with a very small aperture (radius = 1.25"). To achieve the desired wavelength accuracy of <15 km/s, HST+COS must center the target to within 0.1” of the center of the aperture. This is the angle subtended by a typical AAS poster when viewed from over 1400 miles away. During SMOV we have fine-tuned the COS target acquisition (TA) procedures to exceed this accuracy for all three COS TA modes; NUV imaging, NUV spectroscopic, and FUV spectroscopic. We will compare all COS TA modes in terms of centering accuracy, efficiency (elapsed time), and required signal-to-noise for all targets suitable for use with COS. We will also provide updated recommendations for the options of all TA modes (e.g., SCAN-SIZE and NUM-POS of ACQ/PEAKD). We have observed in SMOV that HST is providing an excellent initial 1-σ blind pointing accuracy of ±0.4” in both the along-dispersion and cross-dispersion directions. We will discuss the implications of this, and other lessons learned in SMOV, on Cycle 17 and 18 HST+COS TAs.
Performance of the NASA Digitizing Core-Loss Instrumentation
NASA Technical Reports Server (NTRS)
Schwarze, Gene E. (Technical Monitor); Niedra, Janis M.
2003-01-01
The standard method of magnetic core loss measurement was implemented on a high frequency digitizing oscilloscope in order to explore the limits to accuracy when characterizing high Q cores at frequencies up to 1 MHz. This method computes core loss from the cycle mean of the product of the exciting current in a primary winding and induced voltage in a separate flux sensing winding. It is pointed out that just 20 percent accuracy for a Q of 100 core material requires a phase angle accuracy of 0.1 between the voltage and current measurements. Experiment shows that at 1 MHz, even high quality, high frequency current sensing transformers can introduce phase errors of a degree or more. Due to the fact that the Q of some quasilinear core materials can exceed 300 at frequencies below 100 kHz, phase angle errors can be a problem even at 50 kHz. Hence great care is necessary with current sensing and ground loops when measuring high Q cores. Best high frequency current sensing accuracy was obtained from a fabricated 0.1-ohm coaxial resistor, differentially sensed. Sample high frequency core loss data taken with the setup for a permeability-14 MPP core is presented.
Landsat 8 operational land imager on-orbit geometric calibration and performance
Storey, James C.; Choate, Michael J.; Lee, Kenton
2014-01-01
The Landsat 8 spacecraft was launched on 11 February 2013 carrying the Operational Land Imager (OLI) payload for moderate resolution imaging in the visible, near infrared (NIR), and short-wave infrared (SWIR) spectral bands. During the 90-day commissioning period following launch, several on-orbit geometric calibration activities were performed to refine the prelaunch calibration parameters. The results of these calibration activities were subsequently used to measure geometric performance characteristics in order to verify the OLI geometric requirements. Three types of geometric calibrations were performed including: (1) updating the OLI-to-spacecraft alignment knowledge; (2) refining the alignment of the sub-images from the multiple OLI sensor chips; and (3) refining the alignment of the OLI spectral bands. The aspects of geometric performance that were measured and verified included: (1) geolocation accuracy with terrain correction, but without ground control (L1Gt); (2) Level 1 product accuracy with terrain correction and ground control (L1T); (3) band-to-band registration accuracy; and (4) multi-temporal image-to-image registration accuracy. Using the results of the on-orbit calibration update, all aspects of geometric performance were shown to meet or exceed system requirements.
Pesticide Residue Monitoring on South African Fresh Produce Exported over a 6-Year Period.
Mutengwe, M T; Chidamba, L; Korsten, L
2016-10-01
Six years of pesticide residue data from fresh produce destined for the export market were analyzed for the period 2009 to 2014. A total of 37,838 fruit (99.27%) and vegetable (0.73%) data sets analyzed for the presence of 73 pesticides were compared. Pesticides were detected on 56.46% of samples, of which 0.78% had multiple residues. Noncompliances detected were because of the use of unregistered pesticides (0.73%), values that exceeded established maximum residue levels (MRLs) (0.32%), or the combination of values that exceeded MRLs and the use of unregistered pesticide residues (0.003%). The most commonly detected pesticides that exceeded established MRLs were imazalil (37.71%), prochloraz (28.69%), and iprodione (5.74%). The unregistered pesticide most often found on grapes and avocados was also imazalil (62.23%) and, on nectarines and avocados, diphenylamine (11.15%). Exceedances of MRL values were mostly associated with oranges (43.44%), avocados (27.87%), grapefruits (7.38%), and lemons (6.56%). Residual pesticide monitoring on fruits and vegetables is a key tool to ensure conformity with regulatory requirements and compliance with good agricultural practices and the trade requirements set by the importing country.
Examination of marine and vegetable oil oxidation data from a multi-year, third-party database.
De Boer, Anna A; Ismail, Adam; Marshall, Keri; Bannenberg, Gerard; Yan, Kevin L; Rowe, William J
2018-07-15
Fish oil (FO) products constitute good sources of omega-3 fats. Oxidation data from a large third-party database of 1900 + globally-sourced FO samples were assessed. In FO products, for peroxide value (PV), 13.9% exceeded 5 mEq O 2 /kg (2.2% >10); for acid value (AcV) 2.1% exceeded 3 mg KOH/g, while for p-anisidine value (pAV) in unflavoured oils, 6.1% exceeded 20, (3.8% >30), and 8.8% exceeded TOTOX limits (26). Additionally, we compared FO with other dietary oils. The FO median PV was similar to those of algal and sunflower oils, 4.8-fold greater than krill oil, and 5.2-fold less than extra-virgin olive oil. The median pAV differed non-significantly among oils. The FO median AcV was similar to those of algal and extra-virgin olive oils, 3.4-fold greater than sunflower oil, and 11.9-fold less than krill oil. This study has provided new insight that retail FO products predominantly meet regulatory guidelines and are comparable in oxidative status to other dietary oils. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Sisay, Z. G.; Besha, T.; Gessesse, B.
2017-05-01
This study used in-situ GPS data to validate the accuracy of horizontal coordinates and orientation of linear features of orthophoto and line map for Bahir Dar city. GPS data is processed using GAMIT/GLOBK and Lieca GeoOfice (LGO) in a least square sense with a tie to local and regional GPS reference stations to predict horizontal coordinates at five checkpoints. Real-Time-Kinematic GPS measurement technique is used to collect the coordinates of road centerline to test the accuracy associated with the orientation of the photogrammetric line map. The accuracy of orthophoto was evaluated by comparing with in-situ GPS coordinates and it is in a good agreement with a root mean square error (RMSE) of 12.45 cm in x- and 13.97 cm in y-coordinates, on the other hand, 6.06 cm with 95 % confidence level - GPS coordinates from GAMIT/GLOBK. Whereas, the horizontal coordinates of the orthophoto are in agreement with in-situ GPS coordinates at an accuracy of 16.71 cm and 18.98 cm in x and y-directions respectively and 11.07 cm with 95 % confidence level - GPS data is processed by LGO and a tie to local GPS network. Similarly, the accuracy of linear feature is in a good fit with in-situ GPS measurement. The GPS coordinates of the road centerline deviates from the corresponding coordinates of line map by a mean value of 9.18 cm in x- direction and -14.96 cm in y-direction. Therefore, it can be concluded that, the accuracy of the orthophoto and line map is within the national standard of error budget ( 25 cm).
Differential Effects of Context and Feedback on Orthographic Learning: How Good Is Good Enough?
ERIC Educational Resources Information Center
Martin-Chang, Sandra; Ouellette, Gene; Bond, Linda
2017-01-01
In this study, students in Grade 2 read different sets of words under 4 experimental training conditions (context/feedback, isolation/feedback, context/no-feedback, isolation/no-feedback). Training took place over 10 trials, followed by a spelling test and a delayed reading posttest. Reading in context boosted reading accuracy initially; in…
Hybrid acousto-optic and digital equalization for microwave digital radio channels
NASA Astrophysics Data System (ADS)
Anderson, C. S.; Vanderlugt, A.
1990-11-01
Digital radio transmission systems use complex modulation schemes that require powerful signal-processing techniques to correct channel distortions and to minimize BERs. This paper proposes combining the computation power of acoustooptic processing and the accuracy of digital processing to produce a hybrid channel equalizer that exceeds the performance of digital equalization alone. Analysis shows that a hybrid equalizer for 256-level quadrature amplitude modulation (QAM) performs better than a digital equalizer for 64-level QAM.
Two-photon exchange correction to the hyperfine splitting in muonic hydrogen
NASA Astrophysics Data System (ADS)
Tomalak, Oleksandr
2017-12-01
We reevaluate the Zemach, recoil and polarizability corrections to the hyperfine splitting in muonic hydrogen expressing them through the low-energy proton structure constants and obtain the precise values of the Zemach radius and two-photon exchange (TPE) contribution. The uncertainty of TPE correction to S energy levels in muonic hydrogen of 105 ppm exceeds the ppm accuracy level of the forthcoming 1S hyperfine splitting measurements at PSI, J-PARC and RIKEN-RAL.
Measuring contemporary crustal motions; NASA’s Crustal Dynamics Project
Frey, H. V.; Bosworth, J. M.
1988-01-01
In this article we describe briefly the two space geodetic techniques and how they are used by the Crustal Dynamics Project, show some of the very exciting results that have emerged at the halfway point in the project's life, describe the availability and utilization of the data being collected, and consider what the future may hold when measurement accuracies eventually exceed even those now available and when other international groups become more heavily involved.
Northern Hemisphere observations of ICRF sources on the USNO stellar catalogue frame
NASA Astrophysics Data System (ADS)
Fienga, A.; Andrei, A. H.
2004-06-01
The most recent USNO stellar catalogue, the USNO B1.0 (Monet et al. \\cite{Monet03}), provides positions for 1 042 618 261 objects, with a published astrometric accuracy of 200 mas and five-band magnitudes with a 0.3 mag accuracy. Its completeness is believed to be up to magnitude 21th in V-band. Such a catalogue would be a very good tool for astrometric reduction. This work investigates the accuracy of the USNO B1.0 link to ICRF and give an estimation of its internal and external accuracies by comparison with different catalogues, and by computation of ICRF sources using USNO B1.0 star positions.
Depth calibration of the Experimental Advanced Airborne Research Lidar, EAARL-B
Wright, C. Wayne; Kranenburg, Christine J.; Troche, Rodolfo J.; Mitchell, Richard W.; Nagle, David B.
2016-05-17
The resulting calibrated EAARL-B data were then analyzed and compared with the original reference dataset, the jet-ski-based dataset from the same Fort Lauderdale site, as well as the depth-accuracy requirements of the International Hydrographic Organization (IHO). We do not claim to meet all of the IHO requirements and standards. The IHO minimum depth-accuracy requirements were used as a reference only and we do not address the other IHO requirements such as “ Full Seafloor Search”. Our results show good agreement between the calibrated EAARL-B data and all reference datasets, with results that are within the 95 percent depth accuracy of the IHO Order 1 (a and b) depth-accuracy requirements.
Ahlawat, Shivani; Stern, Steven E; Belzberg, Allan J; Fritz, Jan
2017-07-01
To assess the quality and accuracy of metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) for the diagnosis of lumbosacral neuropathies in patients with metallic implants in the pelvis. Twenty-two subjects with lumbosacral neuropathy following pelvic instrumentation underwent 1.5-T MARS MRI including optimized axial intermediate-weighted and STIR turbo spin echo sequences extending from L5 to the ischial tuberosity. Two readers graded the visibility of the lumbosacral trunk, sciatic, femoral, lateral femoral cutaneous, and obturator nerves and the nerve signal intensity of nerve, architecture, caliber, course, continuity, and skeletal muscle denervation. Clinical examination and electrodiagnostic studies were used as the standard of reference. Descriptive, agreement, and diagnostic performance statistics were applied. Lumbosacral plexus visibility on MARS MRI was good (4) or very good (3) in 92% of cases with 81% exact agreement and a Kendall's W coefficient of 0.811. The obturator nerve at the obturator foramen and the sciatic nerve posterior to the acetabulum had the lowest visibility, with good or very good ratings in only 61% and 77% of cases respectively. The reader agreement for nerve abnormalities on MARS MRI was excellent, ranging from 95.5 to 100%. MARS MRI achieved a sensitivity of 86%, specificity of 67%, positive predictive value of 95%, and negative predictive value of 40%, and accuracy of 83% for the detection of neuropathy. MARS MRI yields high image quality and diagnostic accuracy for the assessment of lumbosacral neuropathies in patients with metallic implants of the pelvis and hips.
Assessing map accuracy in a remotely sensed, ecoregion-scale cover map
Edwards, T.C.; Moisen, Gretchen G.; Cutler, D.R.
1998-01-01
Landscape- and ecoregion-based conservation efforts increasingly use a spatial component to organize data for analysis and interpretation. A challenge particular to remotely sensed cover maps generated from these efforts is how best to assess the accuracy of the cover maps, especially when they can exceed 1000 s/km2 in size. Here we develop and describe a methodological approach for assessing the accuracy of large-area cover maps, using as a test case the 21.9 million ha cover map developed for Utah Gap Analysis. As part of our design process, we first reviewed the effect of intracluster correlation and a simple cost function on the relative efficiency of cluster sample designs to simple random designs. Our design ultimately combined clustered and subsampled field data stratified by ecological modeling unit and accessibility (hereafter a mixed design). We next outline estimation formulas for simple map accuracy measures under our mixed design and report results for eight major cover types and the three ecoregions mapped as part of the Utah Gap Analysis. Overall accuracy of the map was 83.2% (SE=1.4). Within ecoregions, accuracy ranged from 78.9% to 85.0%. Accuracy by cover type varied, ranging from a low of 50.4% for barren to a high of 90.6% for man modified. In addition, we examined gains in efficiency of our mixed design compared with a simple random sample approach. In regard to precision, our mixed design was more precise than a simple random design, given fixed sample costs. We close with a discussion of the logistical constraints facing attempts to assess the accuracy of large-area, remotely sensed cover maps.
Evaluating the accuracy of technicians and pharmacists in checking unit dose medication cassettes.
Ambrose, Peter J; Saya, Frank G; Lovett, Larry T; Tan, Sandy; Adams, Dale W; Shane, Rita
2002-06-15
The accuracy rates of board-registered pharmacy technicians and pharmacists in checking unit dose medication cassettes in the inpatient setting at two separate institutions were examined. Cedars-Sinai Medical Center and Long Beach Memorial Medical Center, both in Los Angeles county, petitioned the California State Board of Pharmacy to approve a waiver of the California Code of Regulations to conduct an experimental program to compare the accuracy of unit dose medication cassettes checked by pharmacists with that of cassettes checked by trained, certified pharmacy technicians. The study consisted of three parts: assessing pharmacist baseline checking accuracy (Phase I), developing a technician-training program and certifying technicians who completed the didactic and practical training (Phase II), and evaluating the accuracy of certified technicians checking unit dose medication cassettes as a daily function (Phase III). Twenty-nine pharmacists and 41 technicians (3 of whom were pharmacy interns) participated in the study. Of the technicians, all 41 successfully completed the didactic and practical training, 39 successfully completed the audits and became certified checkers, and 2 (including 1 of the interns) did not complete the certification audits because they were reassigned to another work area or had resigned. In Phase II, the observed accuracy rate and its lower confidence limit exceeded the predetermined minimum requirement of 99.8% for a certified checker. The mean accuracy rates for technicians were identical at the two institutions (p = 1.0). The difference in mean accuracy rates between pharmacists (99.52%; 95% confidence interval [CI] 99.44-99.58%) and technicians, (99.89%; 95% CI 99.87-99.90%) was significant (p < 0.0001). Inpatient technicians who had been trained and certified in a closely supervised program that incorporated quality assurance mechanisms could safely and accurately check unit dose medication cassettes filled by other technicians.
NASA Astrophysics Data System (ADS)
Hong-bo, Wang; Chang-yin, Zhao; Wei, Zhang; Jin-wei, Zhan; Sheng-xian, Yu
2016-07-01
The Earth gravitational field model is one of the most important dynamic models in satellite orbit computation. Several space gravity missions made great successes in recent years, prompting the publishing of several gravitational filed models. In this paper, two classical (JGM3, EGM96) and four latest (EIGEN-CHAMP05S, GGM03S, GOCE02S, EGM2008) models are evaluated by employing them in the precision orbit determination (POD) and prediction. These calculations are performed based on the laser ranging observation of four Low Earth Orbit (LEO) satellites, including CHAMP, GFZ-1, GRACE-A, and SWARM-A. The residual error of observation in POD is adopted to describe the accuracy of six gravitational field models. The main results we obtained are as follows. (1) For the POD of LEOs, the accuracies of 4 latest models are at the same level, and better than those of 2 classical models; (2) Taking JGM3 as reference, EGM96 model's accuracy is better in most situations, and the accuracies of the 4 latest models are improved by 12%-47% in POD and 63% in prediction, respectively. We also confirm that the model's accuracy in POD is enhanced with the increasing degree and order if they are smaller than 70, and when they exceed 70, the accuracy keeps constant, implying that the model's degree and order truncated to 70 are sufficient to meet the requirement of LEO computation of centimeter precision.
A High-Precision Counter Using the DSP Technique
2004-09-01
DSP is not good enough to process all the 1-second samples. The cache memory is also not sufficient to store all the sampling data. So we cut the...sampling number in a cycle is not good enough to achieve an accuracy less than 2×10-11. For this reason, a correlation operation is performed for... not good enough to process all the 1-second samples. The cache memory is also not sufficient to store all the sampling data. We will solve this
Solnica, Bogdan
2009-01-01
In this issue of Journal of Diabetes Science and Technology, Chang and colleagues present the analytical performance evaluation of the OneTouch® UltraVue™ blood glucose meter. This device is an advanced construction with a color display, used-strip ejector, no-button interface, and short assay time. Accuracy studies were performed using a YSI 2300 analyzer, considered the reference. Altogether, 349 pairs of results covering a wide range of blood glucose concentrations were analyzed. Patients with diabetes performed a significant part of the tests. Obtained results indicate good accuracy of OneTouch UltraVue blood glucose monitoring system, satisfying the International Organization for Standardization recommendations and thereby locating >95% of tests within zone A of the error grid. Results of the precision studies indicate good reproducibility of measurements. In conclusion, the evaluation of the OneTouch UltraVue meter revealed good analytical performance together with convenient handling useful for self-monitoring of blood glucose performed by elderly diabetes patients. PMID:20144432
Solnica, Bogdan
2009-09-01
In this issue of Journal of Diabetes Science and Technology, Chang and colleagues present the analytical performance evaluation of the OneTouch UltraVue blood glucose meter. This device is an advanced construction with a color display, used-strip ejector, no-button interface, and short assay time. Accuracy studies were performed using a YSI 2300 analyzer, considered the reference. Altogether, 349 pairs of results covering a wide range of blood glucose concentrations were analyzed. Patients with diabetes performed a significant part of the tests. Obtained results indicate good accuracy of OneTouch UltraVue blood glucose monitoring system, satisfying the International Organization for Standardization recommendations and thereby locating >95% of tests within zone A of the error grid. Results of the precision studies indicate good reproducibility of measurements. In conclusion, the evaluation of the OneTouch UltraVue meter revealed good analytical performance together with convenient handling useful for self-monitoring of blood glucose performed by elderly diabetes patients. 2009 Diabetes Technology Society.
System considerations for detection and tracking of small targets using passive sensors
NASA Astrophysics Data System (ADS)
DeBell, David A.
1991-08-01
Passive sensors provide only a few discriminants to assist in threat assessment of small targets. Tracking of the small targets provides additional discriminants. This paper discusses the system considerations for tracking small targets using passive sensors, in particular EO sensors. Tracking helps establish good versus bad detections. Discussed are the requirements to be placed on the sensor system's accuracy, with respect to knowledge of the sightline direction. The detection of weak targets sets a requirement for two levels of tracking in order to reduce processor throughput. A system characteristic is the need to track all detections. For low thresholds, this can mean a heavy track burden. Therefore, thresholds must be adaptive in order not to saturate the processors. Second-level tracks must develop a range estimate in order to assess threat. Sensor platform maneuvers are required if the targets are moving. The need for accurate pointing, good stability, and a good update rate will be shown quantitatively, relating to track accuracy and track association.
Guarneri, Paolo; Rocca, Gianpiero; Gobbi, Massimiliano
2008-09-01
This paper deals with the simulation of the tire/suspension dynamics by using recurrent neural networks (RNNs). RNNs are derived from the multilayer feedforward neural networks, by adding feedback connections between output and input layers. The optimal network architecture derives from a parametric analysis based on the optimal tradeoff between network accuracy and size. The neural network can be trained with experimental data obtained in the laboratory from simulated road profiles (cleats). The results obtained from the neural network demonstrate good agreement with the experimental results over a wide range of operation conditions. The NN model can be effectively applied as a part of vehicle system model to accurately predict elastic bushings and tire dynamics behavior. Although the neural network model, as a black-box model, does not provide a good insight of the physical behavior of the tire/suspension system, it is a useful tool for assessing vehicle ride and noise, vibration, harshness (NVH) performance due to its good computational efficiency and accuracy.
ERIC Educational Resources Information Center
Hope, Nicholas C.
Arguing that the benefits from borrowing abroad exceed the costs recently imposed on countries through debt-servicing difficulties, this paper defines debt as an engine of growth, forcing the borrower to produce goods efficiently, export them, and function competitively in the international market. Debt-servicing difficulties of developing nations…
Inner-Sphere Reorganization in Optical Electron Transfer.
1984-03-01
systematic error on Et should not exceed *0.05 eV. Agreement between the & rG s and Et’s in Table I is as good as can be expected in view of the preceding...01.413183101 ~359/413-2 TECHNICAL REPORT DISTRIBUTION LIST, 359 Dr. David Aikens Dr. 0. H. Whitmore Chemistry Department Department of Materials
49 CFR 178.44 - Specification 3HT seamless steel cylinders for aircraft use.
Code of Federal Regulations, 2011 CFR
2011-10-01
... with a water capacity (nominal) of not over 150 pounds and a service pressure of at least 900 psig. (b...., should be held to a minimum consistent with good high stress pressure vessel manufacturing practices. If... wall thickness must be such that the wall stress at the minimum specified test pressure may not exceed...
Contact toxicity of 40 insecticides tested on pandora moth larvae
Robert L. Lyon
1971-01-01
Forty insecticides and an antifeeding compound were tested on pandora moth larvae (Coloradia pandora Blake) in the second and third instars. A total of 21 insecticides were more toxic at LD90 than DDT, providing a good choice of candidates for field testing. Ten exceeded DDT in toxicity tenfold or more. These were, in...
ERIC Educational Resources Information Center
Zhang, Yan; Guo, Yan
2017-01-01
Chinese children of immigrant families are often perceived as good at memorization and rote learning or as polite, obedient, and passive students lacking creativity and criticality. Guided by Multiple Literacies Theory and translanguaging, this study explores how Chinese children in a Mandarin-English bilingual program skillfully navigate…
21 CFR 184.1768 - Sodium lactate.
Code of Federal Regulations, 2014 CFR
2014-04-01
....1768 Sodium lactate. (a) Sodium lactate (C3H5O3Na, CAS Reg. No. 72-17-3) is the sodium salt of lactic acid. It is prepared commercially by the neutralization of lactic acid with sodium hydroxide. (b) The... ingredient is used in food at levels not to exceed current good manufacturing practice. (d) Prior sanctions...
21 CFR 184.1372 - Insoluble glucose isomerase enzyme preparations.
Code of Federal Regulations, 2013 CFR
2013-04-01
... high fructose corn syrup described in § 184.1866. They are derived from recognized species of precisely... ingredient is used as an enzyme, as defined in § 170.3(o)(9) of this chapter, to convert glucose to fructose. (2) The ingredient is used in high fructose corn syrup, at levels not to exceed current good...
21 CFR 184.1372 - Insoluble glucose isomerase enzyme preparations.
Code of Federal Regulations, 2014 CFR
2014-04-01
... isomerase enzyme preparations are used in the production of high fructose corn syrup described in § 184.1866... defined in § 170.3(o)(9) of this chapter, to convert glucose to fructose. (2) The ingredient is used in high fructose corn syrup, at levels not to exceed current good manufacturing practice. [48 FR 5720, Feb...
21 CFR 184.1372 - Insoluble glucose isomerase enzyme preparations.
Code of Federal Regulations, 2011 CFR
2011-04-01
... high fructose corn syrup described in § 184.1866. They are derived from recognized species of precisely... ingredient is used as an enzyme, as defined in § 170.3(o)(9) of this chapter, to convert glucose to fructose. (2) The ingredient is used in high fructose corn syrup, at levels not to exceed current good...
21 CFR 184.1372 - Insoluble glucose isomerase enzyme preparations.
Code of Federal Regulations, 2010 CFR
2010-04-01
... high fructose corn syrup described in § 184.1866. They are derived from recognized species of precisely... ingredient is used as an enzyme, as defined in § 170.3(o)(9) of this chapter, to convert glucose to fructose. (2) The ingredient is used in high fructose corn syrup, at levels not to exceed current good...
21 CFR 184.1372 - Insoluble glucose isomerase enzyme preparations.
Code of Federal Regulations, 2012 CFR
2012-04-01
... high fructose corn syrup described in § 184.1866. They are derived from recognized species of precisely... ingredient is used as an enzyme, as defined in § 170.3(o)(9) of this chapter, to convert glucose to fructose. (2) The ingredient is used in high fructose corn syrup, at levels not to exceed current good...
ERIC Educational Resources Information Center
Landry, Ted J.
2012-01-01
Throughout the literature, leadership and culture are intertwined. Organizational and leadership theorists alike hold that a leader's perceptions and behaviors are significant, if not primary, determinants of an organization's culture and climate. Given that the assistant principal is exceeded in positional authority only by the principal at a…
Stormwater plume detection by MODIS imagery in the southern California coastal ocean
Nezlin, N.P.; DiGiacomo, P.M.; Diehl, D.W.; Jones, B.H.; Johnson, S.C.; Mengel, M.J.; Reifel, K.M.; Warrick, J.A.; Wang, M.
2008-01-01
Stormwater plumes in the southern California coastal ocean were detected by MODIS-Aqua satellite imagery and compared to ship-based data on surface salinity and fecal indicator bacterial (FIB) counts collected during the Bight'03 Regional Water Quality Program surveys in February-March of 2004 and 2005. MODIS imagery was processed using a combined near-infrared/shortwave-infrared (NIR-SWIR) atmospheric correction method, which substantially improved normalized water-leaving radiation (nLw) optical spectra in coastal waters with high turbidity. Plumes were detected using a minimum-distance supervised classification method based on nLw spectra averaged within the training areas, defined as circular zones of 1.5-5.0-km radii around field stations with a surface salinity of S 33.0 ('ocean'). The plume optical signatures (i.e., the nLw differences between 'plume' and 'ocean') were most evident during the first 2 days after the rainstorms. To assess the accuracy of plume detection, stations were classified into 'plume' and 'ocean' using two criteria: (1) 'plume' included the stations with salinity below a certain threshold estimated from the maximum accuracy of plume detection; and (2) FIB counts in 'plume' exceeded the California State Water Board standards. The salinity threshold between 'plume' and 'ocean' was estimated as 32.2. The total accuracy of plume detection in terms of surface salinity was not high (68% on average), seemingly because of imperfect correlation between plume salinity and ocean color. The accuracy of plume detection in terms of FIB exceedances was even lower (64% on average), resulting from low correlation between ocean color and bacterial contamination. Nevertheless, satellite imagery was shown to be a useful tool for the estimation of the extent of potentially polluted plumes, which was hardly achievable by direct sampling methods (in particular, because the grids of ship-based stations covered only small parts of the plumes detected via synoptic MODIS imagery). In most southern California coastal areas, the zones of bacterial contamination were much smaller than the areas of turbid plumes; an exception was the plume of the Tijuana River, where the zone of bacterial contamination was comparable with the zone of plume detected by ocean color. ?? 2008 Elsevier Ltd.
Stormwater plume detection by MODIS imagery in the southern California coastal ocean
NASA Astrophysics Data System (ADS)
Nezlin, Nikolay P.; DiGiacomo, Paul M.; Diehl, Dario W.; Jones, Burton H.; Johnson, Scott C.; Mengel, Michael J.; Reifel, Kristen M.; Warrick, Jonathan A.; Wang, Menghua
2008-10-01
Stormwater plumes in the southern California coastal ocean were detected by MODIS-Aqua satellite imagery and compared to ship-based data on surface salinity and fecal indicator bacterial (FIB) counts collected during the Bight'03 Regional Water Quality Program surveys in February-March of 2004 and 2005. MODIS imagery was processed using a combined near-infrared/shortwave-infrared (NIR-SWIR) atmospheric correction method, which substantially improved normalized water-leaving radiation (nLw) optical spectra in coastal waters with high turbidity. Plumes were detected using a minimum-distance supervised classification method based on nLw spectra averaged within the training areas, defined as circular zones of 1.5-5.0-km radii around field stations with a surface salinity of S < 32.0 ("plume") and S > 33.0 ("ocean"). The plume optical signatures (i.e., the nLw differences between "plume" and "ocean") were most evident during the first 2 days after the rainstorms. To assess the accuracy of plume detection, stations were classified into "plume" and "ocean" using two criteria: (1) "plume" included the stations with salinity below a certain threshold estimated from the maximum accuracy of plume detection; and (2) FIB counts in "plume" exceeded the California State Water Board standards. The salinity threshold between "plume" and "ocean" was estimated as 32.2. The total accuracy of plume detection in terms of surface salinity was not high (68% on average), seemingly because of imperfect correlation between plume salinity and ocean color. The accuracy of plume detection in terms of FIB exceedances was even lower (64% on average), resulting from low correlation between ocean color and bacterial contamination. Nevertheless, satellite imagery was shown to be a useful tool for the estimation of the extent of potentially polluted plumes, which was hardly achievable by direct sampling methods (in particular, because the grids of ship-based stations covered only small parts of the plumes detected via synoptic MODIS imagery). In most southern California coastal areas, the zones of bacterial contamination were much smaller than the areas of turbid plumes; an exception was the plume of the Tijuana River, where the zone of bacterial contamination was comparable with the zone of plume detected by ocean color.
NASA Astrophysics Data System (ADS)
Grabarek, Iwona; Beczkowska, Sylwia
2012-09-01
The article concerns issues connected with the safety of the carriage of dangerous goods. Raising a subject was justified with the rising number of cartages of these goods and the same height of the probability of the appearance of the environmental risk and remaining road users. A specificity of the arrangement was analyzed driver-vehicleenvironment, paying special attention to ergonomic determinants of working conditions of the driver. In the article data of the National Police Headquarters concerning causes of accident involving dangerous goods in the road transport was also described. Exceeding the permissible speed, the non-observance of traffic regulations, as well as the tiredness which resulted in reducing the psychophysical efficiency for the driver were regarded as the root cause of accidents. Conducted analyses allowed to effect the preliminary selection of factors, which accepting the wrong level can constitute the cause of accidents.
How insurance affects altruistic provision in threshold public goods games.
Zhang, Jianlei; Zhang, Chunyan; Cao, Ming
2015-03-13
The occurrence and maintenance of cooperative behaviors in public goods systems have attracted great research attention across multiple disciplines. A threshold public goods game requires a minimum amount of contributions to be collected from a group of individuals for provision to occur. Here we extend the common binary-strategy combination of cooperation and defection by adding a third strategy, called insured cooperation, which corresponds to buying an insurance covering the potential loss resulted from the unsuccessful public goods game. Particularly, only the contributing agents can opt to be insured, which is an effort decreasing the amount of the potential loss occurring. Theoretical computations suggest that when agents face the potential aggregate risk in threshold public goods games, more contributions occur with increasing compensation from insurance. Moreover, permitting the adoption of insurance significantly enhances individual contributions and facilitates provision, especially when the required threshold is high. This work also relates the strategy competition outcomes to different allocation rules once the resulted contributions exceed the threshold point in populations nested within a dilemma.
An automated method for the evaluation of the pointing accuracy of Sun-tracking devices
NASA Astrophysics Data System (ADS)
Baumgartner, Dietmar J.; Pötzi, Werner; Freislich, Heinrich; Strutzmann, Heinz; Veronig, Astrid M.; Rieder, Harald E.
2017-03-01
The accuracy of solar radiation measurements, for direct (DIR) and diffuse (DIF) radiation, depends significantly on the precision of the operational Sun-tracking device. Thus, rigid targets for instrument performance and operation have been specified for international monitoring networks, e.g., the Baseline Surface Radiation Network (BSRN) operating under the auspices of the World Climate Research Program (WCRP). Sun-tracking devices that fulfill these accuracy requirements are available from various instrument manufacturers; however, none of the commercially available systems comprise an automatic accuracy control system allowing platform operators to independently validate the pointing accuracy of Sun-tracking sensors during operation. Here we present KSO-STREAMS (KSO-SunTRackEr Accuracy Monitoring System), a fully automated, system-independent, and cost-effective system for evaluating the pointing accuracy of Sun-tracking devices. We detail the monitoring system setup, its design and specifications, and the results from its application to the Sun-tracking system operated at the Kanzelhöhe Observatory (KSO) Austrian radiation monitoring network (ARAD) site. The results from an evaluation campaign from March to June 2015 show that the tracking accuracy of the device operated at KSO lies within BSRN specifications (i.e., 0.1° tracking accuracy) for the vast majority of observations (99.8 %). The evaluation of manufacturer-specified active-tracking accuracies (0.02°), during periods with direct solar radiation exceeding 300 W m-2, shows that these are satisfied in 72.9 % of observations. Tracking accuracies are highest during clear-sky conditions and on days where prevailing clear-sky conditions are interrupted by frontal movement; in these cases, we obtain the complete fulfillment of BSRN requirements and 76.4 % of observations within manufacturer-specified active-tracking accuracies. Limitations to tracking surveillance arise during overcast conditions and periods of partial solar-limb coverage by clouds. On days with variable cloud cover, 78.1 % (99.9 %) of observations meet active-tracking (BSRN) accuracy requirements while for days with prevailing overcast conditions these numbers reduce to 64.3 % (99.5 %).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parker, G.A.; Pack, R.T
1978-02-15
A simple, direct derivation of the rotational infinite order sudden (IOS) approximation in molecular scattering theory is given. Connections between simple scattering amplitude formulas, choice of average partial wave parameter, and magnetic transitions are reviewed. Simple procedures for calculating cross sections for specific transitions are discussed and many older model formulas are given clear derivations. Total (summed over rotation) differential, integral, and transport cross sections, useful in the analysis of many experiments involving nonspherical molecules, are shown to be exceedingly simple: They are just averages over the potential angle of cross sections calculated using simple structureless spherical particle formulas andmore » programs. In the case of vibrationally inelastic scattering, the IOSA, without further approximation, provides a well-defined way to get fully three dimensional cross sections from calculations no more difficult than collinear calculations. Integral, differential, viscosity, and diffusion cross sections for He-CO/sub 2/ obtained from the IOSA and a realistic intermolecular potential are calculated as an example and compared with experiment. Agreement is good for the complete potential but poor when only its spherical part is used, so that one should never attempt to treat this system with a spherical model. The simplicity and accuracy of the IOSA make it a viable method for routine analysis of experiments involving collisions of nonspherical molecules.« less
Röhnisch, Hanna E; Eriksson, Jan; Müllner, Elisabeth; Agback, Peter; Sandström, Corine; Moazzami, Ali A
2018-02-06
A key limiting step for high-throughput NMR-based metabolomics is the lack of rapid and accurate tools for absolute quantification of many metabolites. We developed, implemented, and evaluated an algorithm, AQuA (Automated Quantification Algorithm), for targeted metabolite quantification from complex 1 H NMR spectra. AQuA operates based on spectral data extracted from a library consisting of one standard calibration spectrum for each metabolite. It uses one preselected NMR signal per metabolite for determining absolute concentrations and does so by effectively accounting for interferences caused by other metabolites. AQuA was implemented and evaluated using experimental NMR spectra from human plasma. The accuracy of AQuA was tested and confirmed in comparison with a manual spectral fitting approach using the ChenomX software, in which 61 out of 67 metabolites quantified in 30 human plasma spectra showed a goodness-of-fit (r 2 ) close to or exceeding 0.9 between the two approaches. In addition, three quality indicators generated by AQuA, namely, occurrence, interference, and positional deviation, were studied. These quality indicators permit evaluation of the results each time the algorithm is operated. The efficiency was tested and confirmed by implementing AQuA for quantification of 67 metabolites in a large data set comprising 1342 experimental spectra from human plasma, in which the whole computation took less than 1 s.
Lead identification in soil surrounding a used lead acid battery smelter area in Banten, Indonesia
NASA Astrophysics Data System (ADS)
Adventini, N.; Santoso, M.; Lestiani, D. D.; Syahfitri, W. Y. N.; Rixson, L.
2017-06-01
A used lead acid battery smelter generates particulates containing lead that can contaminate the surrounding environment area. Lead is a heavy metal which is harmful to health if it enters the human body through soil, air, or water. An identification of lead in soil samples surrounding formal and informal used lead acid battery smelters area in Banten, Indonesia using EDXRF has been carried out. The EDXRF accuracy and precision evaluated from marine sediment IAEA 457 gave a good agreement to the certified value. A number of 16 soil samples from formal and informal areas and 2 soil samples from control area were taken from surface and subsurface soils. The highest lead concentrations from both lead smelter were approximately 9 folds and 11 folds higher than the reference and control samples. The assessment of lead contamination in soils described in Cf index was in category: moderately and strongly polluted by lead for formal and informal lead smelter. Daily lead intake of children in this study from all sites had exceeded the recommended dietary allowance. The HI values for adults and children living near both lead smelter areas were greater than the value of safety threshold 1. This study finding confirmed that there is a potential health risk for inhabitants surrounding the used lead acid battery smelter areas in Banten, Indonesia.
Martin, Elijah H.; Goniche, M.; Klepper, C. Christopher; ...
2015-04-22
Interaction of radio-frequency (RF) waves with the plasma in the near-field of a high-power wave launcher is now seen to be important, both in understanding the channeling of these waves through the plasma boundary and in avoiding power losses in the edge. In a recent Letter a direct non-intrusive measurement of a near antenna RF electric field in the range of lower hybrid (LH) frequencies (more » $$E_{LH}$$) was announced (Phys. Rev. Lett., 110:215005, 2013). The measurement was achieved through the fitting of Balmer series deuterium spectral lines utilizing a time dependent (dynamic) Stark effect model. In this article, the processing of the spectral data is discussed in detail and applied to a larger range of measurements and the accuracy and limitations of the experimental technique is investigated. We find through an analysis of numerous Tore Supra pulses that good quantitative agreement exists between the measured and full-wave modeled $$E_{LH}$$ when the launched power exceeds 0.5MW. For low power the measurement becomes formidable utilizing the implemented passive spectroscopic technique because the spectral noise overwhelms the effect of the RF electric field on the line profile. Additionally, effects of the ponderomotive force are suspected at sufficiently high power.« less
Initial Ada components evaluation
NASA Technical Reports Server (NTRS)
Moebes, Travis
1989-01-01
The SAIC has the responsibility for independent test and validation of the SSE. They have been using a mathematical functions library package implemented in Ada to test the SSE IV and V process. The library package consists of elementary mathematical functions and is both machine and accuracy independent. The SSE Ada components evaluation includes code complexity metrics based on Halstead's software science metrics and McCabe's measure of cyclomatic complexity. Halstead's metrics are based on the number of operators and operands on a logical unit of code and are compiled from the number of distinct operators, distinct operands, and total number of occurrences of operators and operands. These metrics give an indication of the physical size of a program in terms of operators and operands and are used diagnostically to point to potential problems. McCabe's Cyclomatic Complexity Metrics (CCM) are compiled from flow charts transformed to equivalent directed graphs. The CCM is a measure of the total number of linearly independent paths through the code's control structure. These metrics were computed for the Ada mathematical functions library using Software Automated Verification and Validation (SAVVAS), the SSE IV and V tool. A table with selected results was shown, indicating that most of these routines are of good quality. Thresholds for the Halstead measures indicate poor quality if the length metric exceeds 260 or difficulty is greater than 190. The McCabe CCM indicated a high quality of software products.
Assessing skin sensitization hazard in mice and men using non-animal test methods.
Urbisch, Daniel; Mehling, Annette; Guth, Katharina; Ramirez, Tzutzuy; Honarvar, Naveed; Kolle, Susanne; Landsiedel, Robert; Jaworska, Joanna; Kern, Petra S; Gerberick, Frank; Natsch, Andreas; Emter, Roger; Ashikaga, Takao; Miyazawa, Masaaki; Sakaguchi, Hitoshi
2015-03-01
Sensitization, the prerequisite event in the development of allergic contact dermatitis, is a key parameter in both hazard and risk assessments. The pathways involved have recently been formally described in the OECD adverse outcome pathway (AOP) for skin sensitization. One single non-animal test method will not be sufficient to fully address this AOP and in many cases the use of a battery of tests will be necessary. A number of methods are now fully developed and validated. In order to facilitate acceptance of these methods by both the regulatory and scientific communities, results of the single test methods (DPRA, KeratinoSens, LuSens, h-CLAT, (m)MUSST) as well for a the simple '2 out of 3' ITS for 213 substances have been compiled and qualitatively compared to both animal and human data. The dataset was also used to define different mechanistic domains by probable protein-binding mechanisms. In general, the non-animal test methods exhibited good predictivities when compared to local lymph node assay (LLNA) data and even better predictivities when compared to human data. The '2 out of 3' prediction model achieved accuracies of 90% or 79% when compared to human or LLNA data, respectively and thereby even slightly exceeded that of the LLNA. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
Prieto, Ana I; Guzmán-Guillén, Remedios; Díez-Quijada, Leticia; Campos, Alexandre; Vasconcelos, Vitor; Jos, Ángeles; Cameán, Ana M
2018-02-01
Reports on the occurrence of the cyanobacterial toxin cylindrospermopsin (CYN) have increased worldwide because of CYN toxic effects in humans and animals. If contaminated waters are used for plant irrigation, these could represent a possible CYN exposure route for humans. For the first time, a method employing solid phase extraction and quantification by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) of CYN was optimized in vegetables matrices such as lettuce ( Lactuca sativa ). The validated method showed a linear range, from 5 to 500 ng CYN g -1 of fresh weight (f.w.), and detection and quantitation limits (LOD and LOQ) of 0.22 and 0.42 ng CYN g -1 f.w., respectively. The mean recoveries ranged between 85 and 104%, and the intermediate precision from 12.7 to 14.7%. The method showed to be robust for the three different variables tested. Moreover, it was successfully applied to quantify CYN in edible lettuce leaves exposed to CYN-contaminated water (10 µg L -1 ), showing that the tolerable daily intake (TDI) in the case of CYN could be exceeded in elderly high consumers. The validated method showed good results in terms of sensitivity, precision, accuracy, and robustness for CYN determination in leaf vegetables such as lettuce. More studies are needed in order to prevent the risks associated with the consumption of CYN-contaminated vegetables.
Using a 1200 kHz workhorse ADCP with mode 12 to measure near bottom mean currents
Martini, M.; ,
2003-01-01
Using high frequency Acoustic Doppler Current (ADCP) profiling technology, it is possible to make high-resolution measurements of mean current profiles within a few meters of the seabed. In coastal applications, mean current speeds may be 10 cm/s or less, and oscillatory wave currents may exceed 100 cm/s during storm events. To resolve mean flows of 10 cm/s or less under these conditions, accuracies of 1 cm/s or better are desirable.
NASA Technical Reports Server (NTRS)
Adams, D. F.; Hartmann, U. G.; Lazarow, L. L.; Maloy, J. O.; Mohler, G. W.
1976-01-01
The design of the vector magnetometer selected for analysis is capable of exceeding the required accuracy of 5 gamma per vector field component. The principal elements that assure this performance level are very low power dissipation triaxial feedback coils surrounding ring core flux-gates and temperature control of the critical components of two-loop feedback electronics. An analysis of the calibration problem points to the need for improved test facilities.
Double absorbing boundaries for finite-difference time-domain electromagnetics
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaGrone, John, E-mail: jlagrone@smu.edu; Hagstrom, Thomas, E-mail: thagstrom@smu.edu
We describe the implementation of optimal local radiation boundary condition sequences for second order finite difference approximations to Maxwell's equations and the scalar wave equation using the double absorbing boundary formulation. Numerical experiments are presented which demonstrate that the design accuracy of the boundary conditions is achieved and, for comparable effort, exceeds that of a convolution perfectly matched layer with reasonably chosen parameters. An advantage of the proposed approach is that parameters can be chosen using an accurate a priori error bound.
Algorithm Estimates Microwave Water-Vapor Delay
NASA Technical Reports Server (NTRS)
Robinson, Steven E.
1989-01-01
Accuracy equals or exceeds conventional linear algorithms. "Profile" algorithm improved algorithm using water-vapor-radiometer data to produce estimates of microwave delays caused by water vapor in troposphere. Does not require site-specific and weather-dependent empirical parameters other than standard meteorological data, latitude, and altitude for use in conjunction with published standard atmospheric data. Basic premise of profile algorithm, wet-path delay approximated closely by solution to simplified version of nonlinear delay problem and generated numerically from each radiometer observation and simultaneous meteorological data.
Accuracy and borehole influences in pulsed neutron gamma density logging while drilling.
Yu, Huawei; Sun, Jianmeng; Wang, Jiaxin; Gardner, Robin P
2011-09-01
A new pulsed neutron gamma density (NGD) logging has been developed to replace radioactive chemical sources in oil logging tools. The present paper describes studies of near and far density measurement accuracy of NGD logging at two spacings and the borehole influences using Monte-Carlo simulation. The results show that the accuracy of near density is not as good as far density. It is difficult to correct this for borehole effects by using conventional methods because both near and far density measurement is significantly sensitive to standoffs and mud properties. Copyright © 2011 Elsevier Ltd. All rights reserved.
Modelling Multi Hazard Mapping in Semarang City Using GIS-Fuzzy Method
NASA Astrophysics Data System (ADS)
Nugraha, A. L.; Awaluddin, M.; Sasmito, B.
2018-02-01
One important aspect of disaster mitigation planning is hazard mapping. Hazard mapping can provide spatial information on the distribution of locations that are threatened by disaster. Semarang City as the capital of Central Java Province is one of the cities with high natural disaster intensity. Frequent natural disasters Semarang city is tidal flood, floods, landslides, and droughts. Therefore, Semarang City needs spatial information by doing multi hazard mapping to support disaster mitigation planning in Semarang City. Multi Hazards map modelling can be derived from parameters such as slope maps, rainfall, land use, and soil types. This modelling is done by using GIS method with scoring and overlay technique. However, the accuracy of modelling would be better if the GIS method is combined with Fuzzy Logic techniques to provide a good classification in determining disaster threats. The Fuzzy-GIS method will build a multi hazards map of Semarang city can deliver results with good accuracy and with appropriate threat class spread so as to provide disaster information for disaster mitigation planning of Semarang city. from the multi-hazard modelling using GIS-Fuzzy can be known type of membership that has a good accuracy is the type of membership Gauss with RMSE of 0.404 the smallest of the other membership and VAF value of 72.909% of the largest of the other membership.
Design and Application of Automatic Falling Device for Different Brands of Goods
NASA Astrophysics Data System (ADS)
Yang, Xudong; Ge, Qingkuan; Zuo, Ping; Peng, Tao; Dong, Weifu
2017-12-01
The Goods-Falling device is an important device in the intelligent sorting goods sorting system, which is responsible for the temporary storage and counting of the goods, and the function of putting the goods on the conveyor belt according to certain precision requirements. According to the present situation analysis and actual demand of the domestic goods sorting equipment, a vertical type Goods - Falling Device is designed and the simulation model of the device is established. The dynamic characteristics such as the angular error of the opening and closing mechanism are carried out by ADAMS software. The simulation results show that the maximum angular error is 0.016rad. Through the test of the device, the goods falling speed is 7031/hour, the good of the falling position error within 2mm, meet the crawl accuracy requirements of the palletizing robot.
Gjerde, Hallvard; Verstraete, Alain
2010-02-25
To study several methods for estimating the prevalence of high blood concentrations of tetrahydrocannabinol and amphetamine in a population of drug users by analysing oral fluid (saliva). Five methods were compared, including simple calculation procedures dividing the drug concentrations in oral fluid by average or median oral fluid/blood (OF/B) drug concentration ratios or linear regression coefficients, and more complex Monte Carlo simulations. Populations of 311 cannabis users and 197 amphetamine users from the Rosita-2 Project were studied. The results of a feasibility study suggested that the Monte Carlo simulations might give better accuracies than simple calculations if good data on OF/B ratios is available. If using only 20 randomly selected OF/B ratios, a Monte Carlo simulation gave the best accuracy but not the best precision. Dividing by the OF/B regression coefficient gave acceptable accuracy and precision, and was therefore the best method. None of the methods gave acceptable accuracy if the prevalence of high blood drug concentrations was less than 15%. Dividing the drug concentration in oral fluid by the OF/B regression coefficient gave an acceptable estimation of high blood drug concentrations in a population, and may therefore give valuable additional information on possible drug impairment, e.g. in roadside surveys of drugs and driving. If good data on the distribution of OF/B ratios are available, a Monte Carlo simulation may give better accuracy. 2009 Elsevier Ireland Ltd. All rights reserved.
Source accuracy data reveal the thresholded nature of human episodic memory.
Harlow, Iain M; Donaldson, David I
2013-04-01
Episodic recollection supports conscious retrieval of past events. It is unknown why recollected memories are often vivid, but at other times we struggle to remember. Such experiences might reflect a recollection threshold: Either the threshold is exceeded and information is retrieved, or recollection fails completely. Alternatively, retrieval failure could reflect weak memory: Recollection could behave as a continuous signal, always yielding some variable degree of information. Here we reconcile these views, using a novel source memory task that measures retrieval accuracy directly. We show that recollection is thresholded, such that retrieval sometimes simply fails. Our technique clarifies a fundamental property of memory and allows responses to be accurately measured, without recourse to subjective introspection. These findings raise new questions about how successful retrieval is determined and why it declines with age and disease.
Multiclass cancer diagnosis using tumor gene expression signatures
Ramaswamy, S.; Tamayo, P.; Rifkin, R.; ...
2001-12-11
The optimal treatment of patients with cancer depends on establishing accurate diagnoses by using a complex combination of clinical and histopathological data. In some instances, this task is difficult or impossible because of atypical clinical presentation or histopathology. To determine whether the diagnosis of multiple common adult malignancies could be achieved purely by molecular classification, we subjected 218 tumor samples, spanning 14 common tumor types, and 90 normal tissue samples to oligonucleotide microarray gene expression analysis. The expression levels of 16,063 genes and expressed sequence tags were used to evaluate the accuracy of a multiclass classifier based on a supportmore » vector machine algorithm. Overall classification accuracy was 78%, far exceeding the accuracy of random classification (9%). Poorly differentiated cancers resulted in low-confidence predictions and could not be accurately classified according to their tissue of origin, indicating that they are molecularly distinct entities with dramatically different gene expression patterns compared with their well differentiated counterparts. Taken together, these results demonstrate the feasibility of accurate, multiclass molecular cancer classification and suggest a strategy for future clinical implementation of molecular cancer diagnostics.« less
NASA Astrophysics Data System (ADS)
Hurtado, Daniel E.; Rojas, Guillermo
2018-04-01
Computer simulations constitute a powerful tool for studying the electrical activity of the human heart, but computational effort remains prohibitively high. In order to recover accurate conduction velocities and wavefront shapes, the mesh size in linear element (Q1) formulations cannot exceed 0.1 mm. Here we propose a novel non-conforming finite-element formulation for the non-linear cardiac electrophysiology problem that results in accurate wavefront shapes and lower mesh-dependance in the conduction velocity, while retaining the same number of global degrees of freedom as Q1 formulations. As a result, coarser discretizations of cardiac domains can be employed in simulations without significant loss of accuracy, thus reducing the overall computational effort. We demonstrate the applicability of our formulation in biventricular simulations using a coarse mesh size of ˜ 1 mm, and show that the activation wave pattern closely follows that obtained in fine-mesh simulations at a fraction of the computation time, thus improving the accuracy-efficiency trade-off of cardiac simulations.
Efficient Record Linkage Algorithms Using Complete Linkage Clustering.
Mamun, Abdullah-Al; Aseltine, Robert; Rajasekaran, Sanguthevar
2016-01-01
Data from different agencies share data of the same individuals. Linking these datasets to identify all the records belonging to the same individuals is a crucial and challenging problem, especially given the large volumes of data. A large number of available algorithms for record linkage are prone to either time inefficiency or low-accuracy in finding matches and non-matches among the records. In this paper we propose efficient as well as reliable sequential and parallel algorithms for the record linkage problem employing hierarchical clustering methods. We employ complete linkage hierarchical clustering algorithms to address this problem. In addition to hierarchical clustering, we also use two other techniques: elimination of duplicate records and blocking. Our algorithms use sorting as a sub-routine to identify identical copies of records. We have tested our algorithms on datasets with millions of synthetic records. Experimental results show that our algorithms achieve nearly 100% accuracy. Parallel implementations achieve almost linear speedups. Time complexities of these algorithms do not exceed those of previous best-known algorithms. Our proposed algorithms outperform previous best-known algorithms in terms of accuracy consuming reasonable run times.
Validation of minicams for measuring concentrations of chemical agent in environmental air
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menton, R.G.; Hayes, T.L.; Chou, Y.L.
1993-05-13
Environmental monitoring for chemical agents is necessary to ensure that notification and appropriate action will be taken in the, event that there is a release exceeding control limits of such agents into the workplace outside of engineering controls. Prior to implementing new analytical procedures for environmental monitoring, precision and accuracy (PA) tests are conducted to ensure that an agent monitoring system performs according to specified accuracy, precision, and sensitivity requirements. This testing not only establishes the accuracy and precision of the method, but also determines what factors can affect the method's performance. Performance measures that are particularly important in agentmore » monitoring include the Detection Limit (DL), Decision Limit (DC), Found Action Level (FAL), and the Target Action Level (TAL). PA experiments were performed at Battelle's Medical Research and Evaluation Facility (MREF) to validate the use of the miniature chemical agent monitoring system (MINICAMs) for measuring environmental air concentrations of sulfur mustard (HD). This presentation discusses the experimental and statistical approaches for characterizing the performance of MINICAMS for measuring HD in air.« less
Efficient Record Linkage Algorithms Using Complete Linkage Clustering
Mamun, Abdullah-Al; Aseltine, Robert; Rajasekaran, Sanguthevar
2016-01-01
Data from different agencies share data of the same individuals. Linking these datasets to identify all the records belonging to the same individuals is a crucial and challenging problem, especially given the large volumes of data. A large number of available algorithms for record linkage are prone to either time inefficiency or low-accuracy in finding matches and non-matches among the records. In this paper we propose efficient as well as reliable sequential and parallel algorithms for the record linkage problem employing hierarchical clustering methods. We employ complete linkage hierarchical clustering algorithms to address this problem. In addition to hierarchical clustering, we also use two other techniques: elimination of duplicate records and blocking. Our algorithms use sorting as a sub-routine to identify identical copies of records. We have tested our algorithms on datasets with millions of synthetic records. Experimental results show that our algorithms achieve nearly 100% accuracy. Parallel implementations achieve almost linear speedups. Time complexities of these algorithms do not exceed those of previous best-known algorithms. Our proposed algorithms outperform previous best-known algorithms in terms of accuracy consuming reasonable run times. PMID:27124604
Testing of the high accuracy inertial navigation system in the Shuttle Avionics Integration Lab
NASA Technical Reports Server (NTRS)
Strachan, Russell L.; Evans, James M.
1991-01-01
The description, results, and interpretation is presented of comparison testing between the High Accuracy Inertial Navigation System (HAINS) and KT-70 Inertial Measurement Unit (IMU). The objective was to show the HAINS can replace the KT-70 IMU in the space shuttle Orbiter, both singularly and totally. This testing was performed in the Guidance, Navigation, and Control Test Station (GTS) of the Shuttle Avionics Integration Lab (SAIL). A variety of differences between the two instruments are explained. Four, 5 day test sessions were conducted varying the number and slot position of the HAINS and KT-70 IMUs. The various steps in the calibration and alignment procedure are explained. Results and their interpretation are presented. The HAINS displayed a high level of performance accuracy previously unseen with the KT-70 IMU. The most significant improvement of the performance came in the Tuned Inertial/Extended Launch Hold tests. The HAINS exceeded the 4 hr specification requirement. The results obtained from the SAIL tests were generally well beyond the requirements of the procurement specification.
21 CFR 184.1945 - Vitamin B12.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Vitamin B12. 184.1945 Section 184.1945 Food and... Substances Affirmed as GRAS § 184.1945 Vitamin B12. (a) Vitamin B12, also known as cyanocobalamin (C63H88Co... is used in food at levels not to exceed current good manufacturing practice. Vitamin B12 also may be...
21 CFR 74.3102 - FD&C Blue No. 2.
Code of Federal Regulations, 2010 CFR
2010-04-01
... impurities may be avoided by current good manufacturing practice: Sum of volatile matter at 135 °C (275 °F... bone cement shall be prepared in accordance with the requirements of § 82.51 of this chapter. (c) Uses... No. 2-Aluminum Lake on alumina may be safely used for coloring bone cement at a level not to exceed 0...
Localization Algorithm with On-line Path Loss Estimation and Node Selection
Bel, Albert; Vicario, José López; Seco-Granados, Gonzalo
2011-01-01
RSS-based localization is considered a low-complexity algorithm with respect to other range techniques such as TOA or AOA. The accuracy of RSS methods depends on the suitability of the propagation models used for the actual propagation conditions. In indoor environments, in particular, it is very difficult to obtain a good propagation model. For that reason, we present a cooperative localization algorithm that dynamically estimates the path loss exponent by using RSS measurements. Since the energy consumption is a key point in sensor networks, we propose a node selection mechanism to limit the number of neighbours of a given node that are used for positioning purposes. Moreover, the selection mechanism is also useful to discard bad links that could negatively affect the performance accuracy. As a result, we derive a practical solution tailored to the strict requirements of sensor networks in terms of complexity, size and cost. We present results based on both computer simulations and real experiments with the Crossbow MICA2 motes showing that the proposed scheme offers a good trade-off in terms of position accuracy and energy efficiency. PMID:22163992
Comparative analysis of autofocus functions in digital in-line phase-shifting holography.
Fonseca, Elsa S R; Fiadeiro, Paulo T; Pereira, Manuela; Pinheiro, António
2016-09-20
Numerical reconstruction of digital holograms relies on a precise knowledge of the original object position. However, there are a number of relevant applications where this parameter is not known in advance and an efficient autofocusing method is required. This paper addresses the problem of finding optimal focusing methods for use in reconstruction of digital holograms of macroscopic amplitude and phase objects, using digital in-line phase-shifting holography in transmission mode. Fifteen autofocus measures, including spatial-, spectral-, and sparsity-based methods, were evaluated for both synthetic and experimental holograms. The Fresnel transform and the angular spectrum reconstruction methods were compared. Evaluation criteria included unimodality, accuracy, resolution, and computational cost. Autofocusing under angular spectrum propagation tends to perform better with respect to accuracy and unimodality criteria. Phase objects are, generally, more difficult to focus than amplitude objects. The normalized variance, the standard correlation, and the Tenenbaum gradient are the most reliable spatial-based metrics, combining computational efficiency with good accuracy and resolution. A good trade-off between focus performance and computational cost was found for the Fresnelet sparsity method.
Support vector machine incremental learning triggered by wrongly predicted samples
NASA Astrophysics Data System (ADS)
Tang, Ting-long; Guan, Qiu; Wu, Yi-rong
2018-05-01
According to the classic Karush-Kuhn-Tucker (KKT) theorem, at every step of incremental support vector machine (SVM) learning, the newly adding sample which violates the KKT conditions will be a new support vector (SV) and migrate the old samples between SV set and non-support vector (NSV) set, and at the same time the learning model should be updated based on the SVs. However, it is not exactly clear at this moment that which of the old samples would change between SVs and NSVs. Additionally, the learning model will be unnecessarily updated, which will not greatly increase its accuracy but decrease the training speed. Therefore, how to choose the new SVs from old sets during the incremental stages and when to process incremental steps will greatly influence the accuracy and efficiency of incremental SVM learning. In this work, a new algorithm is proposed to select candidate SVs and use the wrongly predicted sample to trigger the incremental processing simultaneously. Experimental results show that the proposed algorithm can achieve good performance with high efficiency, high speed and good accuracy.
Multi-Component Diffusion with Application To Computational Aerothermodynamics
NASA Technical Reports Server (NTRS)
Sutton, Kenneth; Gnoffo, Peter A.
1998-01-01
The accuracy and complexity of solving multicomponent gaseous diffusion using the detailed multicomponent equations, the Stefan-Maxwell equations, and two commonly used approximate equations have been examined in a two part study. Part I examined the equations in a basic study with specified inputs in which the results are applicable for many applications. Part II addressed the application of the equations in the Langley Aerothermodynamic Upwind Relaxation Algorithm (LAURA) computational code for high-speed entries in Earth's atmosphere. The results showed that the presented iterative scheme for solving the Stefan-Maxwell equations is an accurate and effective method as compared with solutions of the detailed equations. In general, good accuracy with the approximate equations cannot be guaranteed for a species or all species in a multi-component mixture. 'Corrected' forms of the approximate equations that ensured the diffusion mass fluxes sum to zero, as required, were more accurate than the uncorrected forms. Good accuracy, as compared with the Stefan- Maxwell results, were obtained with the 'corrected' approximate equations in defining the heating rates for the three Earth entries considered in Part II.
ERIC Educational Resources Information Center
Sy, Jolene R.; Gratz, Olivia; Donaldson, Jeanne M.
2016-01-01
The good behavior game (GBG) is a class-wide contingency management strategy that involves rewarding teams who engage in low levels of disruptive behavior. The GBG has been found to be effective with neuro-typical individuals from preschool to high school. In Study 1, teachers and experimenters implemented the GBG on alternating days in an…
Yu, Yan; Hu, Senke; Yang, Yuxuan; Zhao, Xiaodan; Xue, Jianjun; Zhang, Jinghua; Gao, Song; Yang, Aimin
2017-08-02
A wide range of pesticides is applied for crop protection in vegetable cultivation in China. Regulation of pesticide maximum residue limits (MRLs) in vegetables is established but not fully enforced. And pesticide residues in vegetables were not well monitored. This study conducted the monitoring surveys from 2011 to 2013 to investigate the pesticides in vegetables in the northwest region of China. A multi-residue gas chromatography/mass spectrometry method (GC/MS) was used in determination of pesticides in vegetable samples. The χ 2 test was used to compare the concentration of pesticide residues. A total of 32 pesticide residues were detected in 518 samples from 20 types of vegetables in this study. 7.7% of the detected pesticide residues exceeded the MRLs. The percentages of residues that exceeded the MRLs for leafy, melon and fruit, and root vegetables were 11.2%, 5.1%, and 1.6%, respectively. There was no seasonal difference in the proportion of samples that exceeded the MRLs in different vegetables. A total of 84.3% (27/32) pesticides were detected at concentrations that exceeded MRLs. And of the 27 pesticides that exceeded the MRLs, 11 (40.7%) were banned for use in agriculture. The most frequently detected pesticides were Malathion (9.4%), Dichlorvos (8.7%), and Dimethoate (8.1%). The observed high rate of pesticides detected and high incidence of pesticide detection exceeding their MRLs in the commonly consumed vegetables indicated that the Good Agricultural Practices (GAP) may not be well followed. The management of pesticide use and control should be improved. Well-developed training programs should be initiated to improve pesticide application knowledge for farmers.
Christiansen, Mark; Greene, Carmine; Pardo, Scott; Warchal-Windham, Mary Ellen; Harrison, Bern; Morin, Robert; Bailey, Timothy S
2017-05-01
These studies investigated the accuracy of the new Contour ® Next ONE blood glucose monitoring system (BGMS) that is designed to sync with the Contour™ Diabetes app on a smartphone or tablet. A laboratory study tested fingertip capillary blood samples from 100 subjects in duplicate using 3 test strip lots, based on ISO 15197:2013 Section 6.3 analytical accuracy standards. A clinical study assessed accuracy per ISO 15197:2013 Section 8 criteria. Subjects with (n = 333) or without (n = 43) diabetes and who had not used the BGMS previously were enrolled. Each subject performed a self-test using the BGMS, which was repeated by a site staff member. Alternate site tests and venipunctures were also performed for analysis. A questionnaire was provided to assess user feedback on ease of use. In the laboratory study, 100% (600/600) of combined results for all 3 test strip lots met ISO 15197:2013 Section 6.3 accuracy criteria. In the clinical study, among subjects with diabetes, 99.4% (327/329) of subject self-test results, 99.7% (331/332) of results obtained by study staff, 97.2% (309/318) of subject palm results, and 100% (330/330) of venous results met ISO 15197:2013 Section 8 accuracy criteria. Moreover, 97.6% (321/329) of subject self-test results were within ±10 mg/dl (±0.6 mmol/L) or ±10% of the YSI reference result. Questionnaire results indicated that most subjects considered the system easy to use. The BGMS exceeded ISO 15197:2013 accuracy criteria in the laboratory and in a clinical setting.
Carnley, Mark V.
2016-09-30
The Design Analysis Associates (DAA) DAA H-3613i radar water-level sensor (DAA H-3613i), manufactured by Xylem Incorporated, was evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) for conformance to manufacturer’s accuracy specifications for measuring a distance throughout the sensor’s operating temperature range, for measuring distances from 3 to 15 feet at ambient temperatures, and for compliance with the SDI-12 serial-to-digital interface at 1200-baud communication standard. The DAA H-3613i is a noncontact water-level sensor that uses pulsed radar to measure the distance between the radar and the water surface from 0.75 to 131 feet over a temperature range of −40 to 60 degrees Celsius (°C). Manufacturer accuracy specifications that were evaluated, the test procedures that followed, and the results obtained are described in this report. The sensor’s accuracy specification of ± 0.01 feet (± 3 millimeters) meets USGS requirements for a primary water-stage sensor used in the operation of a streamgage. The sensor met the manufacturer’s stated accuracy specifications for water-level measurements during temperature testing at a distance of 8 feet from the target over its temperature-compensated operating range of −40 to 60 °C, except at 60 °C. At 60 °C, about half the measurements exceeded the manufacturer’s accuracy specification by not more than 0.005 feet.The sensor met the manufacturer’s stated accuracy specifications for water-level measurements during distance-accuracy testing at the tested distances from 3 to 15 feet above the water surface at the HIF.
Depreciation of public goods in spatial public goods games
NASA Astrophysics Data System (ADS)
Shi, Dong-Mei; Zhuang, Yong; Li, Yu-Jian; Wang, Bing-Hong
2011-10-01
In real situations, the value of public goods will be reduced or even lost because of external factors or for intrinsic reasons. In this work, we investigate the evolution of cooperation by considering the effect of depreciation of public goods in spatial public goods games on a square lattice. It is assumed that each individual gains full advantage if the number of the cooperators nc within a group centered on that individual equals or exceeds the critical mass (CM). Otherwise, there is depreciation of the public goods, which is realized by rescaling the multiplication factor r to (nc/CM)r. It is shown that the emergence of cooperation is remarkably promoted for CM > 1 even at small values of r, and a global cooperative level is achieved at an intermediate value of CM = 4 at a small r. We further study the effect of depreciation of public goods on different topologies of a regular lattice, and find that the system always reaches global cooperation at a moderate value of CM = G - 1 regardless of whether or not there exist overlapping triangle structures on the regular lattice, where G is the group size of the associated regular lattice.
Improving default risk prediction using Bayesian model uncertainty techniques.
Kazemi, Reza; Mosleh, Ali
2012-11-01
Credit risk is the potential exposure of a creditor to an obligor's failure or refusal to repay the debt in principal or interest. The potential of exposure is measured in terms of probability of default. Many models have been developed to estimate credit risk, with rating agencies dating back to the 19th century. They provide their assessment of probability of default and transition probabilities of various firms in their annual reports. Regulatory capital requirements for credit risk outlined by the Basel Committee on Banking Supervision have made it essential for banks and financial institutions to develop sophisticated models in an attempt to measure credit risk with higher accuracy. The Bayesian framework proposed in this article uses the techniques developed in physical sciences and engineering for dealing with model uncertainty and expert accuracy to obtain improved estimates of credit risk and associated uncertainties. The approach uses estimates from one or more rating agencies and incorporates their historical accuracy (past performance data) in estimating future default risk and transition probabilities. Several examples demonstrate that the proposed methodology can assess default probability with accuracy exceeding the estimations of all the individual models. Moreover, the methodology accounts for potentially significant departures from "nominal predictions" due to "upsetting events" such as the 2008 global banking crisis. © 2012 Society for Risk Analysis.
Activity Recognition for Personal Time Management
NASA Astrophysics Data System (ADS)
Prekopcsák, Zoltán; Soha, Sugárka; Henk, Tamás; Gáspár-Papanek, Csaba
We describe an accelerometer based activity recognition system for mobile phones with a special focus on personal time management. We compare several data mining algorithms for the automatic recognition task in the case of single user and multiuser scenario, and improve accuracy with heuristics and advanced data mining methods. The results show that daily activities can be recognized with high accuracy and the integration with the RescueTime software can give good insights for personal time management.
Secure Fingerprint Identification of High Accuracy
2014-01-01
secure ) solution of complexity O(n3) based on Gaussian elimination. When it is applied to biometrics X and Y with mX and mY minutiae, respectively...collections of biometric data in use today include, for example, fingerprint, face, and iris images collected by the US Department of Homeland Security ...work we focus on fingerprint data due to popularity and good accuracy of this type of biometry. We formulate the problem of private, or secure , finger
How Much Press Do You Need to Cover a War?
1994-06-17
before they were sent. Journalists , in the end, succumbed to the pressure and reported according to the military’s rules out of respect for American...some good and some bad journalists . True, some reporters just cannot grasp how releasing certain information will aid the enemy or endanger our troops... Reporting Accuracy is a concern of reputable journalists as well as military commanders. But a report lacking accuracy will cost a commander much
TLD postal dose intercomparison for megavoltage units in Poland.
Izewska, J; Gajewski, R; Gwiazdowska, B; Kania, M; Rostkowska, J
1995-08-01
The aim of the TLD pilot study was to investigate and to reduce the uncertainties involved in the measurements of absorbed dose and to improve the consistency in dose determination in the regional radiotherapy centres in Poland. The intercomparison was organized by the SSDL. It covered absorbed dose measurements under reference conditions for Co-60, high energy X-rays and electron beams. LiF powder type MT-N was used for the irradiations and read with the Harshaw TLD reader model 2000B/2000C. The TLD system was set up and an analysis of the factors influencing the accuracy of absorbed dose measurements with TL-detectors was performed to evaluate and minimize the measurement uncertainty. A fading not exceeding 2% in 12 weeks was found. The relative energy correction factor did not exceed 3% for X-rays in the range 4-15 MV, and 4% for electron beams between 6 and 20 MeV. A total of 34 beams was checked. Deviation of +/- 3.5% stated and evaluated dose was considered acceptable for photons and +/- 5% for electron beams. The results for Co-60, high energy X-rays and electron beams showed that there were two, three and no centres, respectively, beyond acceptance levels. The sources of errors for all deviations out of this range were thoroughly investigated, discussed and corrected, however two deviations remained unexplained. The pilot study resulted in an improvement of the accuracy and consistency of dosimetry in Poland.
Diagnostic precision of mentally estimated home blood pressure means.
Ouattara, Franck Olivier; Laskine, Mikhael; Cheong, Nathalie Ng; Birnbaum, Leora; Wistaff, Robert; Bertrand, Michel; van Nguyen, Paul; Kolan, Christophe; Durand, Madeleine; Rinfret, Felix; Lamarre-Cliche, Maxime
2018-05-07
Paper home blood pressure (HBP) charts are commonly brought to physicians at office visits. The precision and accuracy of mental calculations of blood pressure (BP) means are not known. A total of 109 hypertensive patients were instructed to measure and record their HBP for 1 week and to bring their paper charts to their office visit. Study section 1: HBP means were calculated electronically and compared to corresponding in-office BP estimates made by physicians. Study section 2: 100 randomly ordered HBP charts were re-examined repetitively by 11 evaluators. Each evaluator estimated BP means four times in 5, 15, 30, and 60 s (random order) allocated for the task. BP means and diagnostic performance (determination of therapeutic systolic and diastolic BP goals attained or not) were compared between physician estimates and electronically calculated results. Overall, electronically and mentally calculated BP means were not different. Individual analysis showed that 83% of in-office physician estimates were within a 5-mmHg systolic BP range. There was diagnostic disagreement in 15% of cases. Performance improved consistently when the time allocated for BP estimation was increased from 5 to 15 s and from 15 to 30 s, but not when it exceeded 30 s. Mentally calculating HBP means from paper charts can cause a number of diagnostic errors. Chart evaluation exceeding 30 s does not significantly improve accuracy. BP-measuring devices with modern analytical capacities could be useful to physicians.
Accuracy and Reliability Assessment of CT and MR Perfusion Analysis Software Using a Digital Phantom
Christensen, Soren; Sasaki, Makoto; Østergaard, Leif; Shirato, Hiroki; Ogasawara, Kuniaki; Wintermark, Max; Warach, Steven
2013-01-01
Purpose: To design a digital phantom data set for computed tomography (CT) perfusion and perfusion-weighted imaging on the basis of the widely accepted tracer kinetic theory in which the true values of cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), and tracer arrival delay are known and to evaluate the accuracy and reliability of postprocessing programs using this digital phantom. Materials and Methods: A phantom data set was created by generating concentration-time curves reflecting true values for CBF (2.5–87.5 mL/100 g per minute), CBV (1.0–5.0 mL/100 g), MTT (3.4–24 seconds), and tracer delays (0–3.0 seconds). These curves were embedded in human brain images. The data were analyzed by using 13 algorithms each for CT and magnetic resonance (MR), including five commercial vendors and five academic programs. Accuracy was assessed by using the Pearson correlation coefficient (r) for true values. Delay-, MTT-, or CBV-dependent errors and correlations between time to maximum of residue function (Tmax) were also evaluated. Results: In CT, CBV was generally well reproduced (r > 0.9 in 12 algorithms), but not CBF and MTT (r > 0.9 in seven and four algorithms, respectively). In MR, good correlation (r > 0.9) was observed in one-half of commercial programs, while all academic algorithms showed good correlations for all parameters. Most algorithms had delay-dependent errors, especially for commercial software, as well as CBV dependency for CBF or MTT calculation and MTT dependency for CBV calculation. Correlation was good in Tmax except for one algorithm. Conclusion: The digital phantom readily evaluated the accuracy and characteristics of the CT and MR perfusion analysis software. All commercial programs had delay-induced errors and/or insufficient correlations with true values, while academic programs for MR showed good correlations with true values. © RSNA, 2012 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12112618/-/DC1 PMID:23220899
SvSXP: a Strongylus vulgaris antigen with potential for prepatent diagnosis
2013-01-01
Background Strongyle parasites are ubiquitous in grazing horses. Strongylus vulgaris, the most pathogenic of the large strongyles, is known for its extensive migration in the mesenteric arterial system. The lifecycle of S. vulgaris is characterised by a long prepatent period where the migrating larvae are virtually undetectable as there currently is no test available for diagnosing prepatent S. vulgaris infection. Presence of S. vulgaris larvae in the arterial system causes endarteritis and thrombosis with a risk of non-strangulating intestinal infarctions. Emergence of anthelmintic resistance among cyathostomins has led to recommendations of reduced treatment intensity by targeting horses that exceed a predetermined strongyle faecal egg count threshold. One study suggests an apparent increase in prevalence of S. vulgaris on farms where reduced anthelmintic treatment intensity has been implemented. These issues highlight the need for an accurate and reliable assay for diagnosing prepatent S. vulgaris infection. Methods Immunoscreening of a larval S. vulgaris cDNA library using hyperimmune serum raised against S. vulgaris excretory/secretory antigens was performed to identify potential diagnostic antigens. Immunoreactive clones were sequenced, one potential antigen was characterised, expressed as a recombinant protein, initially evaluated by western blot (WB) analysis, the diagnostic potential of the IgG subclasses was evaluated by ELISA, and the diagnostic accuracy evaluated using serum from 102 horses with known S. vulgaris infection status. Results The clone expressing the potential antigen encoded a S. vulgaris SXP/RAL2 homologue. The recombinant protein, rSvSXP, was shown to be a potential diagnostic antigen by WB analysis, and a target of serum IgGa, IgG(T) and total IgG in naturally infected horses, with IgG(T) antibodies being the most reliable indicator of S. vulgaris infection in horses. Evaluation of diagnostic accuracy of the ELISA resulted in a sensitivity of 73.3%, a specificity of 81.0%, a diagnostic odds ratio of 11.69; a positive likelihood ratio (LR) of 3.85 and a negative LR was 0.33. The area under the ROC curve was 0.820. Conclusion IgG(T) antibodies to recombinant SvSXP show potential for use as an antigen for prepatent diagnosis of migrating stages of S. vulgaris with moderate to good diagnostic accuracy. PMID:23557195
Ground-Water Quality in the Genesee River Basin, New York, 2005-2006
Eckhardt, David A.V.; Reddy, J.E.; Tamulonis, Kathryn L.
2007-01-01
Water samples were collected from 7 community water system wells and 15 private domestic wells throughout the Genesee River Basin in New York State (downstream from the Pennsylvania border) from October 2005 through March 2006 and analyzed to characterize the chemical quality of ground water in the basin. The wells were selected to represent areas of greatest ground-water use and to provide a representative sampling from the 2,439 square-mile basin area in New York. Samples were analyzed for five physical properties and 226 constituents that included nutrients, major inorganic ions, trace elements, radionuclides, pesticides, volatile organic compounds, and bacteria. The results show that ground water used for drinking water is generally of good quality in the Genesee River Basin, although concentrations of seven constituents exceeded drinking water standards. The cations that were detected in the highest concentrations were calcium, magnesium, and sodium; the anions that were detected in the greatest concentrations were bicarbonate, chloride, and sulfate. The predominant nutrient was nitrate, and nitrate concentrations were greater in samples from sand and gravel aquifers than in samples from bedrock aquifers. The trace elements barium, boron, cobalt, copper, and nickel were detected in every sample; the highest concentrations were barium, boron, chromium, iron, manganese, strontium, and lithium. Fourteen pesticides including seven pesticide degradates were detected in water from 12 of the 22 wells, but none of the concentrations exceeded Maximum Contaminant Levels (MCLs). Eight volatile organic compounds (VOCs) were detected in six samples, but none of the concentrations exceeded MCLs. Seven chemical analytes and three types of bacteria were present in concentrations that exceeded Federal and New York State water-quality standards, which are typically identical. Sulfate concentrations exceeded the U.S. Environmental Protection Agency (USEPA) Secondary Maximum Contaminant Level (SMCL) of 250 milligrams per liter (mg/L) in three samples; the chloride SMCL (250 mg/L) was exceeded in one sample. Sodium concentrations exceeded the USEPA Drinking Water Health Advisory of 60 mg/L in five samples. The SMCL for iron (300 ug/L) was exceeded in 11 filtered samples; the USEPA SMCL for manganese (50 ug/L) was exceeded in 10 filtered samples, and the New York State MCL (300 ug/L) was exceeded in 1 filtered sample. The MCL for aluminum (200 ug/L) was exceeded in 1 sample, and the MCL for arsenic (10 ug/L) was exceeded in 1 sample. Radon-222 exceeded the proposed USEPA MCL of 300 picocuries per liter in 16 samples. Any detection of total coliform or fecal coliform bacteria is considered a violation of New York State health regulations; in this study, total coliform was detected in eight samples; fecal coliform was detected in two samples, and Escherichia coli was detected in one sample.
Research on effect of rough surface on FMCW laser radar range accuracy
NASA Astrophysics Data System (ADS)
Tao, Huirong
2018-03-01
The non-cooperative targets large scale measurement system based on frequency-modulated continuous-wave (FMCW) laser detection and ranging technology has broad application prospects. It is easy to automate measurement without cooperative targets. However, the complexity and diversity of the surface characteristics of the measured surface directly affects the measurement accuracy. First, the theoretical analysis of range accuracy for a FMCW laser radar was studied, the relationship between surface reflectivity and accuracy was obtained. Then, to verify the effect of surface reflectance for ranging accuracy, a standard tool ball and three standard roughness samples were measured within 7 m to 24 m. The uncertainty of each target was obtained. The results show that the measurement accuracy is found to increase as the surface reflectivity gets larger. Good agreements were obtained between theoretical analysis and measurements from rough surfaces. Otherwise, when the laser spot diameter is smaller than the surface correlation length, a multi-point averaged measurement can reduce the measurement uncertainty. The experimental results show that this method is feasible.
Comparing Features for Classification of MEG Responses to Motor Imagery.
Halme, Hanna-Leena; Parkkonen, Lauri
2016-01-01
Motor imagery (MI) with real-time neurofeedback could be a viable approach, e.g., in rehabilitation of cerebral stroke. Magnetoencephalography (MEG) noninvasively measures electric brain activity at high temporal resolution and is well-suited for recording oscillatory brain signals. MI is known to modulate 10- and 20-Hz oscillations in the somatomotor system. In order to provide accurate feedback to the subject, the most relevant MI-related features should be extracted from MEG data. In this study, we evaluated several MEG signal features for discriminating between left- and right-hand MI and between MI and rest. MEG was measured from nine healthy participants imagining either left- or right-hand finger tapping according to visual cues. Data preprocessing, feature extraction and classification were performed offline. The evaluated MI-related features were power spectral density (PSD), Morlet wavelets, short-time Fourier transform (STFT), common spatial patterns (CSP), filter-bank common spatial patterns (FBCSP), spatio-spectral decomposition (SSD), and combined SSD+CSP, CSP+PSD, CSP+Morlet, and CSP+STFT. We also compared four classifiers applied to single trials using 5-fold cross-validation for evaluating the classification accuracy and its possible dependence on the classification algorithm. In addition, we estimated the inter-session left-vs-right accuracy for each subject. The SSD+CSP combination yielded the best accuracy in both left-vs-right (mean 73.7%) and MI-vs-rest (mean 81.3%) classification. CSP+Morlet yielded the best mean accuracy in inter-session left-vs-right classification (mean 69.1%). There were large inter-subject differences in classification accuracy, and the level of the 20-Hz suppression correlated significantly with the subjective MI-vs-rest accuracy. Selection of the classification algorithm had only a minor effect on the results. We obtained good accuracy in sensor-level decoding of MI from single-trial MEG data. Feature extraction methods utilizing both the spatial and spectral profile of MI-related signals provided the best classification results, suggesting good performance of these methods in an online MEG neurofeedback system.
NASA Astrophysics Data System (ADS)
Liu, Youshan; Teng, Jiwen; Xu, Tao; Badal, José
2017-05-01
The mass-lumped method avoids the cost of inverting the mass matrix and simultaneously maintains spatial accuracy by adopting additional interior integration points, known as cubature points. To date, such points are only known analytically in tensor domains, such as quadrilateral or hexahedral elements. Thus, the diagonal-mass-matrix spectral element method (SEM) in non-tensor domains always relies on numerically computed interpolation points or quadrature points. However, only the cubature points for degrees 1 to 6 are known, which is the reason that we have developed a p-norm-based optimization algorithm to obtain higher-order cubature points. In this way, we obtain and tabulate new cubature points with all positive integration weights for degrees 7 to 9. The dispersion analysis illustrates that the dispersion relation determined from the new optimized cubature points is comparable to that of the mass and stiffness matrices obtained by exact integration. Simultaneously, the Lebesgue constant for the new optimized cubature points indicates its surprisingly good interpolation properties. As a result, such points provide both good interpolation properties and integration accuracy. The Courant-Friedrichs-Lewy (CFL) numbers are tabulated for the conventional Fekete-based triangular spectral element (TSEM), the TSEM with exact integration, and the optimized cubature-based TSEM (OTSEM). A complementary study demonstrates the spectral convergence of the OTSEM. A numerical example conducted on a half-space model demonstrates that the OTSEM improves the accuracy by approximately one order of magnitude compared to the conventional Fekete-based TSEM. In particular, the accuracy of the 7th-order OTSEM is even higher than that of the 14th-order Fekete-based TSEM. Furthermore, the OTSEM produces a result that can compete in accuracy with the quadrilateral SEM (QSEM). The high accuracy of the OTSEM is also tested with a non-flat topography model. In terms of computational efficiency, the OTSEM is more efficient than the Fekete-based TSEM, although it is slightly costlier than the QSEM when a comparable numerical accuracy is required.
Kim, Choon-Mee; Cho, Min Keun; Yun, Na-Ra; Kim, Seok Won; Jang, Sook Jin; Ahn, Young-Joon; Lim, Donghoon
2015-01-01
We retrospectively evaluated the accuracy of conventional PCR targeting the 16S rRNA gene (16S C-PCR) using the Ot-16sRF1/Ot-16sRR1 primers for diagnosing scrub typhus. The diagnosis of Orientia tsutsugamushi infection by 16S C-PCR presented an increased sensitivity of 87.0% and specificity of 100% compared with those obtained with other targets and is thus a simple and clinically useful method with good diagnostic accuracy. PMID:26491185
Tickner, James; Ganly, Brianna; Lovric, Bojan; O'Dwyer, Joel
2017-04-01
Mining companies rely on chemical analysis methods to determine concentrations of gold in mineral ore samples. As gold is often mined commercially at concentrations around 1 part-per-million, it is necessary for any analysis method to provide good sensitivity as well as high absolute accuracy. We describe work to improve both the sensitivity and accuracy of the gamma activation analysis (GAA) method for gold. We present analysis results for several suites of ore samples and discuss the design of a GAA facility designed to replace conventional chemical assay in industrial applications. Copyright © 2017. Published by Elsevier Ltd.
Leung, Ming Yin; Lo, John; Leung, Yiu Yan
2016-11-01
Three-dimensional (3D) images are taken with positioning devices to ensure a patient's stability, which, however, place the patient's head into a random orientation. Reorientation of images to the natural head position (NHP) is necessary for appropriate assessment of dentofacial deformities before any surgical planning. The aim of this study was to review the literature systematically to identify and evaluate the various modalities available to record the NHP in 3 dimensions and to compare their accuracy. A systematic literature search of the PubMed, Cochrane Library and Embase databases, with no limitations on publication time or language, was performed in July 2015. The search and evaluations of articles were performed in 4 rounds. The methodologies, accuracies, advantages, and limitations of various modalities to record NHP were examined. Eight articles were included in the final review. Six modalities to record NHP were identified, namely 1) stereophotogrammetry, 2) facial markings along laser lines, 3) clinical photographs and the pose from orthography and scaling with iterations (POSIT) algorithm, 4) digital orientation sensing, 5) handheld 3D camera measuring system, and 6) laser scanning. Digital orientation sensing had good accuracy, with mean angular differences from the reference within 1° (0.07 ± 0.49° and 0.12 ± 0.54°, respectively). Laser scanning was shown to be comparable to digital orientation sensing. The method involving clinical photographs and the POSIT algorithm was reported to have good accuracy, with mean angular differences for pitch, roll, and yaw within 1° (-0.17 ± 0.50°). Stereophotogrammetry was reported to have the highest reliability, with mean angular deviations in pitch, roll, and yaw for active and passive stereophotogrammetric devices within 0.1° (0.004771 ± 0.045645° and 0.007572 ± 0.079088°, respectively). This systematic review showed that recording the NHP in 3 dimensions with a digital orientation sensor has good accuracy. Laser scanning was found to have comparable accuracy to digital orientation sensing, but routine clinical use was limited by its high cost and low portability. Stereophotogrammetry and the method using a single clinical photograph and the POSIT algorithm were potential alternatives. Nevertheless, clinical trials are needed to verify their applications in patients. Preferably, digital orientation sensor should be used as a reference for comparison with new proposed methods of recording the NHP in future research. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
van Gorp, Karly; Segers, Eliane; Verhoeven, Ludo
2017-04-01
The direct, retention, and transfer effects of repeated word and pseudoword reading were studied in a pretest, training, posttest, retention design. First graders (48 good readers, 47 poor readers) read 25 CVC words and 25 CVC pseudowords in ten repeated word reading sessions, preceded and followed by a transfer task with a different set of items. Two weeks after training, trained items were assessed again in a retention test. Participants either received phonics feedback, in which each word was spelled out and repeated; word feedback, in which each word was repeated; or no feedback. During the training, both good and poor readers improved in accuracy and speed. The increase in speed was stronger for poor readers than for good readers. The good readers demonstrated a stronger increase for pseudowords than for words. This increase in speed was most prominent in the first four sessions. Two weeks after training, the levels of accuracy and speed were retained. Furthermore, transfer effects on speed were found for pseudowords in both groups of readers. Good readers performed most accurately during the training when they received no feedback while poor readers performed most accurately during the training with the help of phonics feedback. However, feedback did not differentiate for reading speed or for effects after the training. The effects of repeated word reading were found to be stronger for poor readers than for good readers. Moreover, these effects were found to be stronger for pseudowords than for words. This indicates that repeated word reading can be seen as an important trigger for the improvement of decoding skills.
Wijk, Ulrika; Brandsma, J Wim; Dahlström, Orjan; Björk, Mathilda
2013-03-01
Leprosy is endemic in many countries and results in activity limitations. There is a need for assessment tools to guide professionals in their evaluation and choice of intervention in order to improve conditions for leprosy-affected people. The purpose of our study was to evaluate the concurrent validity of the Amharic version of Screening of Activity Limitation and Safety Awareness (SALSA-am) scale with Amharic version of Disability of the Arm, Shoulder and Hand (DASH-am) questionnaire. Thirty-eight individuals with nerve damage due to leprosy completed the SALSA-am and DASH-am questionnaires. Spearman's rank correlation was used to determine relationships between SALSA and DASH scores. Specificity, sensitivity and accuracy were calculated. There was a good correlation 0.87 (P < 0.001) between SALSA-am and DASH-am scores. Sensitivity, specificity and accuracy were calculated with acceptable results. SALSA-am is considered a useful questionnaire for determining activity limitations in persons affected by leprosy, and showed good correlation with DASH-am. The concurrent validity was considered good.
Using Markov Chains and Multi-Objective Optimization for Energy-Efficient Context Recognition.
Janko, Vito; Luštrek, Mitja
2017-12-29
The recognition of the user's context with wearable sensing systems is a common problem in ubiquitous computing. However, the typically small battery of such systems often makes continuous recognition impractical. The strain on the battery can be reduced if the sensor setting is adapted to each context. We propose a method that efficiently finds near-optimal sensor settings for each context. It uses Markov chains to simulate the behavior of the system in different configurations and the multi-objective genetic algorithm to find a set of good non-dominated configurations. The method was evaluated on three real-life datasets and found good trade-offs between the system's energy expenditure and the system's accuracy. One of the solutions, for example, consumed five-times less energy than the default one, while sacrificing only two percentage points of accuracy.
Reliability and type of consumer health documents on the World Wide Web: an annotation study.
Martin, Melanie J
2011-01-01
In this paper we present a detailed scheme for annotating medical web pages designed for health care consumers. The annotation is along two axes: first, by reliability (the extent to which the medical information on the page can be trusted), second, by the type of page (patient leaflet, commercial, link, medical article, testimonial, or support). We analyze inter-rater agreement among three judges for each axis. Inter-rater agreement was moderate (0.77 accuracy, 0.62 F-measure, 0.49 Kappa) on the page reliability axis and good (0.81 accuracy, 0.72 F-measure, 0.73 Kappa) along the page type axis. We have shown promising results in this study that appropriate classes of pages can be developed and used by human annotators to annotate web pages with reasonable to good agreement. No.
Analytical parameters of the microplate-based ORAC-pyrogallol red assay.
Ortiz, Rocío; Antilén, Mónica; Speisky, Hernán; Aliaga, Margarita E; López-Alarcón, Camilo
2011-01-01
The analytical parameters of the microplate-based oxygen radicals absorbance capacity (ORAC) method using pyrogallol red (PGR) as probe (ORAC-PGR) are presented. In addition, the antioxidant capacity of commercial beverages, such as wines, fruit juices, and iced teas, is estimated. A good linearity of the area under the curve (AUC) versus Trolox concentration plots was obtained [AUC = (845 +/- 110) + (23 +/- 2) [Trolox, microM], R = 0.9961, n = 19]. QC experiments showed better precision and accuracy at the highest Trolox concentration (40 microM) with RSD and REC (recuperation) values of 1.7 and 101.0%, respectively. When red wine was used as sample, the method also showed good linearity [AUC = (787 +/- 77) + (690 +/- 60) [red wine, microL/mL]; R = 0.9926, n = 17], precision and accuracy with RSD values from 1.4 to 8.3%, and REC values that ranged from 89.7 to 103.8%. Additivity assays using solutions containing gallic acid and Trolox (or red wine) showed an additive protection of PGR given by the samples. Red wines showed higher ORAC-PGR values than white wines, while the ORAC-PGR index of fruit juices and iced teas presented a great variability, ranging from 0.6 to 21.6 mM of Trolox equivalents. This variability was also observed for juices of the same fruit, showing the influence of the brand on the ORAC-PGR index. The ORAC-PGR methodology can be applied in a microplate reader with good linearity, precision, and accuracy.
Emile, Sameh Hany; Magdy, Alaa; Youssef, Mohamed; Thabet, Waleed; Abdelnaby, Mahmoud; Omar, Waleed; Khafagy, Wael
2017-11-01
Tridimensional endoanal ultrasonography (3D-EAUS) has been used for the assessment of various anorectal lesions. Previous studies have reported good accuracy of 3D-EAUS in preoperative assessment of fistula-in-ano (FIA). This study aimed to assess the diagnostic utility of 3D-EAUS in preoperative evaluation of primary and recurrent FIA and its role in detection of associated anal sphincter (AS) defects. Prospectively collected data of patients with FIA who were investigated with 3D-EAUS were reviewed. The findings of EAUS were compared with the intraoperative findings, the reference standard, to find the degree of agreement regarding the position of the internal opening (IO) and primary tract (PT), and presence of secondary tracts using kappa (k) coefficient test. A subgroup analysis was performed to compare the accuracy and sensitivity of EAUS for primary and recurrent FIA. Of the patients, 131 were included to the study. EAUS had an overall accuracy of 87, 88.5, and 89.5% in detection of IO, PT, and AS defects, respectively. There was very good concordance between the findings of EAUS and intraoperative findings for the investigated parameters (kappa = 0.748, 0.83, 0.935), respectively. Accuracy and sensitivity of EAUS in recurrent FIA were insignificantly lower than primary cases. EAUS detected occult AS defects in 5.3% of the patients studied. The diagnostic utility of 3D-EAUS was comparable in primary and recurrent FIA. 3D-EAUS was able to detect symptomatic and occult AS defects with higher accuracy than clinical examination.
ERIC Educational Resources Information Center
Vincent, Jeff
2015-01-01
In many parts of the United States it is difficult for families, particularly low- or moderate-income families, to be able to afford a suitable home in a transit rich neighborhood with good schools. Neighborhoods with all three elements are exceedingly rare. As a result, people often have to sacrifice one of three elements to make their lives…
NASA Astrophysics Data System (ADS)
Bratchenko, Ivan A.; Artemyev, Dmitry N.; Myakinin, Oleg O.; Khristoforova, Yulia A.; Moryatov, Alexander A.; Kozlov, Sergey V.; Zakharov, Valery P.
2017-02-01
The differentiation of skin melanomas and basal cell carcinomas (BCCs) was demonstrated based on combined analysis of Raman and autofluorescence spectra stimulated by visible and NIR lasers. It was ex vivo tested on 39 melanomas and 40 BCCs. Six spectroscopic criteria utilizing information about alteration of melanin, porphyrins, flavins, lipids, and collagen content in tumor with a comparison to healthy skin were proposed. The measured correlation between the proposed criteria makes it possible to define weakly correlated criteria groups for discriminant analysis and principal components analysis application. It was shown that the accuracy of cancerous tissues classification reaches 97.3% for a combined 6-criteria multimodal algorithm, while the accuracy determined separately for each modality does not exceed 79%. The combined 6-D method is a rapid and reliable tool for malignant skin detection and classification.
NASA Technical Reports Server (NTRS)
Lansing, F. L.; Chai, V. W.; Lascu, D.; Urbenajo, R.; Wong, P.
1978-01-01
The engineering manual provides a complete companion documentation about the structure of the main program and subroutines, the preparation of input data, the interpretation of output results, access and use of the program, and the detailed description of all the analytic, logical expressions and flow charts used in computations and program structure. A numerical example is provided and solved completely to show the sequence of computations followed. The program is carefully structured to reduce both user's time and costs without sacrificing accuracy. The user would expect a cost of CPU time of approximately $5.00 per building zone excluding printing costs. The accuracy, on the other hand, measured by deviation of simulated consumption from watt-hour meter readings, was found by many simulation tests not to exceed + or - 10 percent margin.
Working times of elastomeric impression materials determined by dimensional accuracy.
Tan, E; Chai, J; Wozniak, W T
1996-01-01
The working times of five poly(vinyl siloxane) impression materials were estimated by evaluating the dimensional accuracy of stone dies of impressions of a standard model made at successive time intervals. The stainless steel standard model was represented by two abutments having known distances between landmarks in three dimensions. Three dimensions in the x-, y-, and z-axes of the stone dies were measured with a traveling microscope. A time interval was rejected as being within the working time if the percentage change of the resultant dies, in any dimension, was statistically different from those measured from stone dies from previous time intervals. The absolute dimensions of those dies from the rejected time interval also must have exceeded all those from previous time intervals. Results showed that the working times estimated with this method generally were about 30 seconds longer than those recommended by the manufacturers.
McLawhorn, Alexander S; Carroll, Kaitlin M; Blevins, Jason L; DeNegre, Scott T; Mayman, David J; Jerabek, Seth A
2015-10-01
Template-directed instrumentation (TDI) for total knee arthroplasty (TKA) may streamline operating room (OR) workflow and reduce costs by preselecting implants and minimizing instrument tray burden. A decision model simulated the economics of TDI. Sensitivity analyses determined thresholds for model variables to ensure TDI success. A clinical pilot was reviewed. The accuracy of preoperative templates was validated, and 20 consecutive primary TKAs were performed using TDI. The model determined that preoperative component size estimation should be accurate to ±1 implant size for 50% of TKAs to implement TDI. The pilot showed that preoperative template accuracy exceeded 97%. There were statistically significant improvements in OR turnover time and in-room time for TDI compared to an historical cohort of TKAs. TDI reduces costs and improves OR efficiency. Copyright © 2015 Elsevier Inc. All rights reserved.
Measuring earthquakes from optical satellite images.
Van Puymbroeck, N; Michel, R; Binet, R; Avouac, J P; Taboury, J
2000-07-10
Système pour l'Observation de la Terre images are used to map ground displacements induced by earthquakes. Deformations (offsets) induced by stereoscopic effect and roll, pitch, and yaw of satellite and detector artifacts are estimated and compensated. Images are then resampled in a cartographic projection with a low-bias interpolator. A subpixel correlator in the Fourier domain provides two-dimensional offset maps with independent measurements approximately every 160 m. Biases on offsets are compensated from calibration. High-frequency noise (0.125 m(-1)) is approximately 0.01 pixels. Low-frequency noise (lower than 0.001 m(-1)) exceeds 0.2 pixels and is partially compensated from modeling. Applied to the Landers earthquake, measurements show the fault with an accuracy of a few tens of meters and yields displacement on the fault with an accuracy of better than 20 cm. Comparison with a model derived from geodetic data shows that offsets bring new insights into the faulting process.
Age-Related Differences in Multiple Task Monitoring
Todorov, Ivo; Del Missier, Fabio; Mäntylä, Timo
2014-01-01
Coordinating multiple tasks with narrow deadlines is particularly challenging for older adults because of age related decline in cognitive control functions. We tested the hypothesis that multiple task performance reflects age- and gender-related differences in executive functioning and spatial ability. Young and older adults completed a multitasking session with four monitoring tasks as well as separate tasks measuring executive functioning and spatial ability. For both age groups, men exceeded women in multitasking, measured as monitoring accuracy. Individual differences in executive functioning and spatial ability were independent predictors of young adults' monitoring accuracy, but only spatial ability was related to sex differences. For older adults, age and executive functioning, but not spatial ability, predicted multitasking performance. These results suggest that executive functions contribute to multiple task performance across the adult life span and that reliance on spatial skills for coordinating deadlines is modulated by age. PMID:25215609
Age-related differences in multiple task monitoring.
Todorov, Ivo; Del Missier, Fabio; Mäntylä, Timo
2014-01-01
Coordinating multiple tasks with narrow deadlines is particularly challenging for older adults because of age related decline in cognitive control functions. We tested the hypothesis that multiple task performance reflects age- and gender-related differences in executive functioning and spatial ability. Young and older adults completed a multitasking session with four monitoring tasks as well as separate tasks measuring executive functioning and spatial ability. For both age groups, men exceeded women in multitasking, measured as monitoring accuracy. Individual differences in executive functioning and spatial ability were independent predictors of young adults' monitoring accuracy, but only spatial ability was related to sex differences. For older adults, age and executive functioning, but not spatial ability, predicted multitasking performance. These results suggest that executive functions contribute to multiple task performance across the adult life span and that reliance on spatial skills for coordinating deadlines is modulated by age.
Measuring and accounting for the intensity of nursing care: is it worthwhile?
Finkler, Steven A
2008-05-01
In June 2007, the Robert Wood Johnson Foundation sponsored a conference titled "The Economics of Nursing: Paying for Quality Nursing Care." The second topic at the conference was "the appropriateness and feasibility of measuring and accounting for the intensity of nursing care." Drs. Welton and Sermeus presented papers on that topic. This response to those papers focuses on why the hospital industry has not always accounted for and measured nursing intensity. Then it asks, "Why do we want more accurate information about nursing resources used by different patients?" It is not sufficient to say the data regarding nursing costs are not accurate. Nor is it sufficient to say that we now can improve the accuracy of the data. To move forward in this area, we need to develop compelling evidence and arguments that indicate that nursing-cost data of greater accuracy have a benefit that will exceed the costs of that data collection.
NASA astrophysics - Optical systems to explore the universe
NASA Technical Reports Server (NTRS)
Pellerin, C. J., Jr.; Stencel, R. E.
1983-01-01
Major and minor NASA astrophysical research efforts in the near-term are outlined, together with projections of direction for future projects. The Space Telescope is being readied for a 1986 launch and will feature an f/24, 2.4 m aperture, an MgF2 mirror with better than 1/60 wavelength accuracy and will be diffraction-limited in the UV. Pointing accuracy is designed to be 0.007 arcsec for 24 hr. Optical, spectrometric, and photometric equipment will be included. Around 1990, Shuttle-based missions will include an IR telescope and a subarcsec solar surface imaging device. A free-flying X-ray observatory (AXAF) is planned and will include a sensitivity that exceeds that of the HEAO-2 spacecraft by two orders of magnitude. Instruments are under development for higher resolution UV, gamma-ray, and IR studies. In-orbit interferometry is being studied and will depend on in-orbit assembly and servicing of stable structures with segmented optics.
Tomography for two-dimensional gas temperature distribution based on TDLAS
NASA Astrophysics Data System (ADS)
Luo, Can; Wang, Yunchu; Xing, Fei
2018-03-01
Based on tunable diode laser absorption spectroscopy (TDLAS), the tomography is used to reconstruct the combustion gas temperature distribution. The effects of number of rays, number of grids, and spacing of rays on the temperature reconstruction results for parallel ray are researched. The reconstruction quality is proportional to the ray number. The quality tends to be smoother when the ray number exceeds a certain value. The best quality is achieved when η is between 0.5 and 1. A virtual ray method combined with the reconstruction algorithms is tested. It is found that virtual ray method is effective to improve the accuracy of reconstruction results, compared with the original method. The linear interpolation method and cubic spline interpolation method, are used to improve the calculation accuracy of virtual ray absorption value. According to the calculation results, cubic spline interpolation is better. Moreover, the temperature distribution of a TBCC combustion chamber is used to validate those conclusions.
NASA Astrophysics Data System (ADS)
Darwish, Ibrahim A.; Abdine, Heba H.; Amer, Sawsan M.; Al-Rayes, Lama I.
2009-05-01
Spectrophotometric study was carried out, for the first time, to investigate the reaction between the antidepressant fluvoxamine (FXM) and 1,2-naphthoquinone-4-sulphonate (NQS) reagent. In alkaline medium (pH 9), an orange-colored product exhibiting maximum absorption peak ( λmax) at 470 nm was produced. The kinetics of the reaction was investigated and its activation energy was found to be 2.65 kcal mol -1. Because of this low activation energy, the reaction proceeded easily. The stoichiometry of the reaction was determined and the reaction mechanism was postulated. This color-developing reaction was successfully employed in the development of simple and rapid spectrophotometric method for determination of FXM in its pharmaceutical dosage forms. Under the optimized reaction conditions, Beer's law correlating the absorbance ( A) with FXM concentration ( C) was obeyed in the range of 0.6-8 μg ml -1. The regression equation for the calibration data was A = 0.0086 + 0.1348 C, with good correlation coefficient (0.9996). The molar absorptivity ( ɛ) was 5.9 × 10 4 l mol -1 cm -1. The limits of detection and quantification were 0.2 and 0.6 μg ml -1, respectively. The precision of the method was satisfactory; the values of relative standard deviations did not exceed 2%. The proposed method was successfully applied to the determination of FXM in its pharmaceutical tablets with good accuracy and precisions; the label claim percentage was 100.47 ± 0.96%. The results obtained by the proposed method were comparable with those obtained by the official method. The proposed method is superior to all the previously reported spectrophotometric methods for determination of FXM in terms of its simplicity and sensitivity. The method is practical and valuable for its routine application in quality control laboratories for analysis of FXM.
Arsenic exposure in drinking water: an unrecognized health threat in Peru.
George, Christine Marie; Sima, Laura; Arias, M Helena Jahuira; Mihalic, Jana; Cabrera, Lilia Z; Danz, David; Checkley, William; Gilman, Robert H
2014-08-01
To assess the extent of arsenic contamination of groundwater and surface water in Peru and, to evaluate the accuracy of the Arsenic Econo-Quick(™) (EQ) kit for measuring water arsenic concentrations in the field. Water samples were collected from 151 water sources in 12 districts of Peru, and arsenic concentrations were measured in the laboratory using inductively-coupled plasma mass spectrometry. The EQ field kit was validated by comparing a subset of 139 water samples analysed by laboratory measurements and the EQ kit. In 86% (96/111) of the groundwater samples, arsenic exceeded the 10 µg/l arsenic concentration guideline given by the World Health Organization (WHO) for drinking water. In 56% (62/111) of the samples, it exceeded the Bangladeshi threshold of 50 µg/l; the mean concentration being 54.5 µg/l (range: 0.1-93.1). In the Juliaca and Caracoto districts, in 96% (27/28) of groundwater samples arsenic was above the WHO guideline; and in water samples collected from the section of the Rímac river running through Lima, all had arsenic concentrations exceeding the WHO limit. When validated against laboratory values, the EQ kit correctly identified arsenic contamination relative to the guideline in 95% (106/111) of groundwater and in 68% (19/28) of surface water samples. In several districts of Peru, drinking water shows widespread arsenic contamination, exceeding the WHO arsenic guideline. This poses a public health threat requiring further investigation and action. For groundwater samples, the EQ kit performed well relative to the WHO arsenic limit and therefore could provide a vital tool for water arsenic surveillance.
Prottengeier, Johannes; Albermann, Matthias; Heinrich, Sebastian; Birkholz, Torsten; Gall, Christine; Schmidt, Joachim
2016-12-01
Intravenous access in prehospital emergency care allows for early administration of medication and extended measures such as anaesthesia. Cannulation may, however, be difficult, and failure and resulting delay in treatment and transport may have negative effects on the patient. Therefore, our study aims to perform a concise assessment of the difficulties of prehospital venous cannulation. We analysed 23 candidate predictor variables on peripheral venous cannulations in terms of cannulation failure and exceedance of a 2 min time threshold. Multivariate logistic regression models were fitted for variables of predictive value (P<0.25) and evaluated by the area under the curve (AUC>0.6) of their respective receiver operating characteristic curve. A total of 762 intravenous cannulations were enroled. In all, 22% of punctures failed on the first attempt and 13% of punctures exceeded 2 min. Model selection yielded a three-factor model (vein visibility without tourniquet, vein palpability with tourniquet and insufficient ambient lighting) of fair accuracy for the prediction of puncture failure (AUC=0.76) and a structurally congruent model of four factors (failure model factors plus vein visibility with tourniquet) for the exceedance of the 2 min threshold (AUC=0.80). Our study offers a simple assessment to identify cases of difficult intravenous access in prehospital emergency care. Of the numerous factors subjectively perceived as possibly exerting influences on cannulation, only the universal - not exclusive to emergency care - factors of lighting, vein visibility and palpability proved to be valid predictors of cannulation failure and exceedance of a 2 min threshold.
Liquid chromatography tandem-mass spectrometry (LC-MS/MS)- based methods such as isobaric tags for relative and absolute quantification (iTRAQ) and tandem mass tags (TMT) have been shown to provide overall better quantification accuracy and reproducibility over other LC-MS/MS techniques. However, large scale projects like the Clinical Proteomic Tumor Analysis Consortium (CPTAC) require comparisons across many genomically characterized clinical specimens in a single study and often exceed the capability of traditional iTRAQ-based quantification.
DOE Office of Scientific and Technical Information (OSTI.GOV)
2016-06-01
The Connected Traveler framework seeks to boost the energy efficiency of personal travel and the overall transportation system by maximizing the accuracy of predicted traveler behavior in response to real-time feedback and incentives. It is anticipated that this approach will establish a feedback loop that 'learns' traveler preferences and customizes incentives to meet or exceed energy efficiency targets by empowering individual travelers with information needed to make energy-efficient choices and reducing the complexity required to validate transportation system energy savings. This handout provides an overview of NREL's Connected Traveler project, including graphics, milestones, and contact information.
Collective gradient sensing and chemotaxis: modeling and recent developments
NASA Astrophysics Data System (ADS)
Camley, Brian A.
2018-06-01
Cells measure a vast variety of signals, from their environment’s stiffness to chemical concentrations and gradients; physical principles strongly limit how accurately they can do this. However, when many cells work together, they can cooperate to exceed the accuracy of any single cell. In this topical review, I will discuss the experimental evidence showing that cells collectively sense gradients of many signal types, and the models and physical principles involved. I also propose new routes by which experiments and theory can expand our understanding of these problems.
Evaluating space weather forecasts of geomagnetic activity from a user perspective
NASA Astrophysics Data System (ADS)
Thomson, A. W. P.
2000-12-01
Decision Theory can be used as a tool for discussing the relative costs of complacency and false alarms with users of space weather forecasts. We describe a new metric for the value of space weather forecasts, derived from Decision Theory. In particular we give equations for the level of accuracy that a forecast must exceed in order to be useful to a specific customer. The technique is illustrated by simplified example forecasts for global geomagnetic activity and for geophysical exploration and power grid management in the British Isles.
Flight evaluation of LORAN-C in the State of Vermont
NASA Technical Reports Server (NTRS)
Mackenzie, F. D.; Lytle, C. D.
1981-01-01
A flight evaluation of LORAN C as a supplement to existing navigation aids for general aviation aircraft, particularly in mountainous regions of the United States and where VOR coverage is limited was conducted. Flights, initiated in the summer months, extend through four seasons and practically all weather conditions typical of northeastern U.S. operations. Assessment of all the data available indicates that LORAN C signals are suitable as a means of navigation during enroute, terminal and nonprecision approach operations and the performance exceeds the minimum accuracy criteria.
An Acousto-Optical Sensor with High Angular Resolution
Kaloshin, Gennady; Lukin, Igor
2012-01-01
The paper introduces a new laser interferometry-based sensor for diagnosis of random media by means of high accuracy angle measurements and describes the results of its development and testing. Theoretical calculations of the dependence of the range of the laser interferometer on laser beam parameters, device geometry, and atmospheric turbulence characteristics are reported. It is demonstrated that at moderate turbulence intensities corresponding to those observed most frequently in turbulent atmosphere at moderate latitudes and with low interference contrast values, the performance range of the laser interferometer-based device exceeds 5 km. PMID:22737034
NASA Technical Reports Server (NTRS)
Kumer, J. B.; Sterritt, L. W.; Roche, A. E.; Rosenberg, W. J.; Morrow, H. E.; Shenk, W. E.; Susskind, J.
1992-01-01
A concept for a low earth orbiting nadir etalon spectrometer sounder (LeoNESS) is described which can achieve retrieval of temperature, H2O, surface, boundary conditions, cloudiness, and trace species with an accuracy that meets or exceeds the AIRS specifications. Options employing 65-K and 30-K detectors are examined; the former may be implemented via passive radiative cooling. The concept, which is derived from the Cryogenic Limb Array Etalon Spectrometer, has the potential for improving the horizontal and vertical resolution.
Sodium levels in Canadian fast-food and sit-down restaurants.
Scourboutakos, Mary J; L'Abbé, Mary R
2013-01-31
To evaluate the sodium levels in Canadian restaurant and fast-food chain menu items. Nutrition information was collected from the websites of major sit-down (n=20) and fast-food (n=65) restaurants across Canada in 2010 and a database was constructed. Four thousand and forty-four meal items, baked goods, side dishes and children's items were analyzed. Sodium levels were compared to the recommended adequate intake level (AI), tolerable upper intake level (UL) and the US National Sodium Reduction Initiative (NSRI) targets. On average, individual sit-down restaurant menu items contained 1455 mg sodium/serving (or 97% of the AI level of 1500 mg/day). Forty percent of all sit-down restaurant items exceeded the AI for sodium and more than 22% of sit-down restaurant stir fry entrées, sandwiches/wraps, ribs, and pasta entrées with meat/seafood exceeded the daily UL for sodium (2300 mg). Fast-food restaurant meal items contained, on average, 1011 mg sodium (68% of the daily AI), while side dishes (from sit-down and fast-food restaurants) contained 736 mg (49%). Children's meal items contained, on average, 790 mg/serving (66% of the sodium AI for children of 1200 mg/day); a small number of children's items exceeded the children's daily UL. On average, 52% of establishments exceeded the 2012 NSRI density targets and 69% exceeded the 2014 targets. The sodium content in Canadian restaurant foods is alarmingly high. A population-wide sodium reduction strategy needs to address the high levels of sodium in restaurant foods.
NASA Technical Reports Server (NTRS)
Montez, M. N.
1980-01-01
The results of a six degree of freedom (6-DOF) nonlinear Monte Carlo dispersion analysis for the latest glide return to landing site (GRTLS) abort trajectory for the Space Transportation System 1 Flight are presented. For this GRTLS, the number two main engine fails at 262.5 seconds ground elapsed time. Fifty randomly selected simulations, initialized at external tank separation, are analyzed. The initial covariance matrix is a 20 x 20 matrix and includes navigation errors and dispersions in position and velocity, time, accelerometer bias, and inertial platform misalinements. In all 50 samples, speedbrake, rudder, elevon, and body flap hinge moments are acceptable. Transitions to autoland begin before 9,000 feet and there are no tailscrapes. Navigation derived dynamic pressure accuracies exceed the flight control system constraints above Mach 2.5. Three out of 50 landings exceeded tire specification limit speed of 222 knots. Pilot manual landings are expected to reduce landing speed by landing farther downrange.
Wiegner, T N; Edens, C J; Abaya, L M; Carlson, K M; Lyon-Colbert, A; Molloy, S L
2017-01-30
Spatial and temporal patterns of coastal microbial pollution are not well documented. Our study examined these patterns through measurements of fecal indicator bacteria (FIB), nutrients, and physiochemical parameters in Hilo Bay, Hawai'i, during high and low river flow. >40% of samples tested positive for the human-associated Bacteroides marker, with highest percentages near rivers. Other FIB were also higher near rivers, but only Clostridium perfringens concentrations were related to discharge. During storms, FIB concentrations were three times to an order of magnitude higher, and increased with decreasing salinity and water temperature, and increasing turbidity. These relationships and high spatial resolution data for these parameters were used to create Enterococcus spp. and C. perfringens maps that predicted exceedances with 64% and 95% accuracy, respectively. Mapping microbial pollution patterns and predicting exceedances is a valuable tool that can improve water quality monitoring and aid in visualizing FIB hotspots for management actions. Copyright © 2016 Elsevier Ltd. All rights reserved.
Attribute Weighting Based K-Nearest Neighbor Using Gain Ratio
NASA Astrophysics Data System (ADS)
Nababan, A. A.; Sitompul, O. S.; Tulus
2018-04-01
K- Nearest Neighbor (KNN) is a good classifier, but from several studies, the result performance accuracy of KNN still lower than other methods. One of the causes of the low accuracy produced, because each attribute has the same effect on the classification process, while some less relevant characteristics lead to miss-classification of the class assignment for new data. In this research, we proposed Attribute Weighting Based K-Nearest Neighbor Using Gain Ratio as a parameter to see the correlation between each attribute in the data and the Gain Ratio also will be used as the basis for weighting each attribute of the dataset. The accuracy of results is compared to the accuracy acquired from the original KNN method using 10-fold Cross-Validation with several datasets from the UCI Machine Learning repository and KEEL-Dataset Repository, such as abalone, glass identification, haberman, hayes-roth and water quality status. Based on the result of the test, the proposed method was able to increase the classification accuracy of KNN, where the highest difference of accuracy obtained hayes-roth dataset is worth 12.73%, and the lowest difference of accuracy obtained in the abalone dataset of 0.07%. The average result of the accuracy of all dataset increases the accuracy by 5.33%.
40 CFR 91.314 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2012 CFR
2012-07-01
... to § 91.325 and § 91.409. (c) Emission measurement accuracy—bag sampling. (1) Good engineering... deflection should generally not be used. (2) Some high resolution read-out systems, such as computers, data...
40 CFR 91.314 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2013 CFR
2013-07-01
... to § 91.325 and § 91.409. (c) Emission measurement accuracy—bag sampling. (1) Good engineering... deflection should generally not be used. (2) Some high resolution read-out systems, such as computers, data...
40 CFR 91.314 - Analyzer accuracy and specifications.
Code of Federal Regulations, 2011 CFR
2011-07-01
... to § 91.325 and § 91.409. (c) Emission measurement accuracy—bag sampling. (1) Good engineering... deflection should generally not be used. (2) Some high resolution read-out systems, such as computers, data...
NASA Technical Reports Server (NTRS)
1990-01-01
Magnetic Resonance Imaging (MRI) and Computer-aided Tomography (CT) images are often complementary. In most cases, MRI is good for viewing soft tissue but not bone, while CT images are good for bone but not always good for soft tissue discrimination. Physicians and engineers in the Department of Radiology at the University of Michigan Hospitals are developing a technique for combining the best features of MRI and CT scans to increase the accuracy of discriminating one type of body tissue from another. One of their research tools is a computer program called HICAP. The program can be used to distinguish between healthy and diseased tissue in body images.
Groundwater quality in the Lake Champlain and Susquehanna River basins, New York, 2014
Scott, Tia-Marie; Nystrom, Elizabeth A.; Reddy, James E.
2016-11-04
In a study conducted by the U.S. Geological Survey in cooperation with the New York State Department of Environmental Conservation, groundwater samples were collected from 6 production wells and 7 domestic wells in the Lake Champlain Basin and from 11 production wells and 9 domestic wells in the Susquehanna River Basin in New York. All samples were collected from June through December 2014 to characterize groundwater quality in these basins. The samples were collected and processed using standard procedures of the U.S. Geological Survey and were analyzed for 148 physiochemical properties and constituents, including dissolved gases, major ions, nutrients, trace elements, pesticides, volatile organic compounds, radionuclides, and indicator bacteria.The Lake Champlain Basin study area covers the 3,050 square miles of the basin in northeastern New York; the remaining part of the basin is in Vermont and Canada. Of the 13 wells sampled in the Lake Champlain Basin, 6 are completed in sand and gravel, and 7 are completed in bedrock. Groundwater in the Lake Champlain Basin was generally of good quality, although properties and concentrations of some constituents— fluoride, iron, manganese, dissolved solids, sodium, radon-222, total coliform bacteria, fecal coliform bacteria, and Escherichia coli bacteria—sometimes equaled or exceeded primary, secondary, or proposed drinking-water standards. The constituent most frequently detected in concentrations exceeding drinking-water standards (5 of 13 samples) was radon-222.The Susquehanna River Basin study area covers the entire 4,522 square miles of the basin in south-central New York; the remaining part of the basin is in Pennsylvania. Of the 20 wells sampled in the Susquehanna River Basin, 11 are completed in sand and gravel, and 9 are completed in bedrock. Groundwater in the Susquehanna River Basin was generally of good quality, although properties and concentrations of some constituents—pH, chloride, sodium, dissolved solids, iron, manganese, aluminum, arsenic, barium, gross-alpha radioactivity, radon-222, methane, total coliform bacteria, and fecal coliform bacteria—sometimes equaled or exceeded primary, secondary, or proposed drinking-water standards. As in the Lake Champlain Basin, the constituent most frequently detected in concentrations exceeding drinking-water standards (13 of 20 samples) was radon-222.
NASA Astrophysics Data System (ADS)
Rounds, S. A.; Sullivan, A. B.
2004-12-01
Assessing a model's ability to reproduce field data is a critical step in the modeling process. For any model, some method of determining goodness-of-fit to measured data is needed to aid in calibration and to evaluate model performance. Visualizations and graphical comparisons of model output are an excellent way to begin that assessment. At some point, however, model performance must be quantified. Goodness-of-fit statistics, including the mean error (ME), mean absolute error (MAE), root mean square error, and coefficient of determination, typically are used to measure model accuracy. Statistical tools such as the sign test or Wilcoxon test can be used to test for model bias. The runs test can detect phase errors in simulated time series. Each statistic is useful, but each has its limitations. None provides a complete quantification of model accuracy. In this study, a suite of goodness-of-fit statistics was applied to a model of Henry Hagg Lake in northwest Oregon. Hagg Lake is a man-made reservoir on Scoggins Creek, a tributary to the Tualatin River. Located on the west side of the Portland metropolitan area, the Tualatin Basin is home to more than 450,000 people. Stored water in Hagg Lake helps to meet the agricultural and municipal water needs of that population. Future water demands have caused water managers to plan for a potential expansion of Hagg Lake, doubling its storage to roughly 115,000 acre-feet. A model of the lake was constructed to evaluate the lake's water quality and estimate how that quality might change after raising the dam. The laterally averaged, two-dimensional, U.S. Army Corps of Engineers model CE-QUAL-W2 was used to construct the Hagg Lake model. Calibrated for the years 2000 and 2001 and confirmed with data from 2002 and 2003, modeled parameters included water temperature, ammonia, nitrate, phosphorus, algae, zooplankton, and dissolved oxygen. Several goodness-of-fit statistics were used to quantify model accuracy and bias. Model performance was judged to be excellent for water temperature (annual ME: -0.22 to 0.05 ° C; annual MAE: 0.62 to 0.68 ° C) and dissolved oxygen (annual ME: -0.28 to 0.18 mg/L; annual MAE: 0.43 to 0.92 mg/L), showing that the model is sufficiently accurate for future water resources planning and management.
Research of Face Recognition with Fisher Linear Discriminant
NASA Astrophysics Data System (ADS)
Rahim, R.; Afriliansyah, T.; Winata, H.; Nofriansyah, D.; Ratnadewi; Aryza, S.
2018-01-01
Face identification systems are developing rapidly, and these developments drive the advancement of biometric-based identification systems that have high accuracy. However, to develop a good face recognition system and to have high accuracy is something that’s hard to find. Human faces have diverse expressions and attribute changes such as eyeglasses, mustache, beard and others. Fisher Linear Discriminant (FLD) is a class-specific method that distinguishes facial image images into classes and also creates distance between classes and intra classes so as to produce better classification.
Translation position determination in ptychographic coherent diffraction imaging.
Zhang, Fucai; Peterson, Isaac; Vila-Comamala, Joan; Diaz, Ana; Berenguer, Felisa; Bean, Richard; Chen, Bo; Menzel, Andreas; Robinson, Ian K; Rodenburg, John M
2013-06-03
Accurate knowledge of translation positions is essential in ptychography to achieve a good image quality and the diffraction limited resolution. We propose a method to retrieve and correct position errors during the image reconstruction iterations. Sub-pixel position accuracy after refinement is shown to be achievable within several tens of iterations. Simulation and experimental results for both optical and X-ray wavelengths are given. The method improves both the quality of the retrieved object image and relaxes the position accuracy requirement while acquiring the diffraction patterns.
Continuous Glucose Monitoring and Trend Accuracy
Gottlieb, Rebecca; Le Compte, Aaron; Chase, J. Geoffrey
2014-01-01
Continuous glucose monitoring (CGM) devices are being increasingly used to monitor glycemia in people with diabetes. One advantage with CGM is the ability to monitor the trend of sensor glucose (SG) over time. However, there are few metrics available for assessing the trend accuracy of CGM devices. The aim of this study was to develop an easy to interpret tool for assessing trend accuracy of CGM data. SG data from CGM were compared to hourly blood glucose (BG) measurements and trend accuracy was quantified using the dot product. Trend accuracy results are displayed on the Trend Compass, which depicts trend accuracy as a function of BG. A trend performance table and Trend Index (TI) metric are also proposed. The Trend Compass was tested using simulated CGM data with varying levels of error and variability, as well as real clinical CGM data. The results show that the Trend Compass is an effective tool for differentiating good trend accuracy from poor trend accuracy, independent of glycemic variability. Furthermore, the real clinical data show that the Trend Compass assesses trend accuracy independent of point bias error. Finally, the importance of assessing trend accuracy as a function of BG level is highlighted in a case example of low and falling BG data, with corresponding rising SG data. This study developed a simple to use tool for quantifying trend accuracy. The resulting trend accuracy is easily interpreted on the Trend Compass plot, and if required, performance table and TI metric. PMID:24876437
QUADAS and STARD: evaluating the quality of diagnostic accuracy studies.
Oliveira, Maria Regina Fernandes de; Gomes, Almério de Castro; Toscano, Cristiana Maria
2011-04-01
To compare the performance of two approaches, one based on the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) and another on the Standards for Reporting Studies of Diagnostic Accuracy (STARD), in evaluating the quality of studies validating the OptiMal® rapid malaria diagnostic test. Articles validating the rapid test published until 2007 were searched in the Medline/PubMed database. This search retrieved 13 articles. A combination of 12 QUADAS criteria and three STARD criteria were compared with the 12 QUADAS criteria alone. Articles that fulfilled at least 50% of QUADAS criteria were considered as regular to good quality. Of the 13 articles retrieved, 12 fulfilled at least 50% of QUADAS criteria, and only two fulfilled the STARD/QUADAS criteria combined. Considering the two criteria combination (> 6 QUADAS and > 3 STARD), two studies (15.4%) showed good methodological quality. The articles selection using the proposed combination resulted in two to eight articles, depending on the number of items assumed as cutoff point. The STARD/QUADAS combination has the potential to provide greater rigor when evaluating the quality of studies validating malaria diagnostic tests, given that it incorporates relevant information not contemplated in the QUADAS criteria alone.
Decay Properties of K-Vacancy States in Fe X-Fe XVII
NASA Technical Reports Server (NTRS)
Mendoza, C.; Kallman, T. R.; Bautista, M. A.; Palmeri, P.
2003-01-01
We report extensive calculations of the decay properties of fine-structure K-vacancy levels in Fe X-Fe XVII. A large set of level energies, wavelengths, radiative and Auger rates, and fluorescence yields has been computed using three different standard atomic codes, namely Cowan's HFR, AUTOSTRUCTURE and the Breit-Pauli R-matrix package. This multi-code approach is used to the study the effects of core relaxation, configuration interaction and the Breit interaction, and enables the estimate of statistical accuracy ratings. The Ksigma and KLL Auger widths have been found to be nearly independent of both the outer-electron configuration and electron occupancy keeping a constant ratio of 1.53 +/- 0.06. By comparing with previous theoretical and measured wavelengths, the accuracy of the present set is determined to be within 2 m Angstrom. Also, the good agreement found between the different radiative and Auger data sets that have been computed allow us to propose with confidence an accuracy rating of 20% for the line fluorescence yields greater than 0.01. Emission and absorption spectral features are predicted finding good correlation with measurements in both laboratory and astrophysical plasmas.
A hybrid localization technique for patient tracking.
Rodionov, Denis; Kolev, George; Bushminkin, Kirill
2013-01-01
Nowadays numerous technologies are employed for tracking patients and assets in hospitals or nursing homes. Each of them has advantages and drawbacks. For example, WiFi localization has relatively good accuracy but cannot be used in case of power outage or in the areas with poor WiFi coverage. Magnetometer positioning or cellular network does not have such problems but they are not as accurate as localization with WiFi. This paper describes technique that simultaneously employs different localization technologies for enhancing stability and average accuracy of localization. The proposed algorithm is based on fingerprinting method paired with data fusion and prediction algorithms for estimating the object location. The core idea of the algorithm is technology fusion using error estimation methods. For testing accuracy and performance of the algorithm testing simulation environment has been implemented. Significant accuracy improvement was showed in practical scenarios.
Scheerlinck, Thierry; Polfliet, Mathias; Deklerck, Rudi; Van Gompel, Gert; Buls, Nico; Vandemeulebroucke, Jef
2016-01-01
We developed a marker-free automated CT-based spatial analysis (CTSA) method to detect stem-bone migration in consecutive CT datasets and assessed the accuracy and precision in vitro. Our aim was to demonstrate that in vitro accuracy and precision of CTSA is comparable to that of radiostereometric analysis (RSA). Stem and bone were segmented in 2 CT datasets and both were registered pairwise. The resulting rigid transformations were compared and transferred to an anatomically sound coordinate system, taking the stem as reference. This resulted in 3 translation parameters and 3 rotation parameters describing the relative amount of stem-bone displacement, and it allowed calculation of the point of maximal stem migration. Accuracy was evaluated in 39 comparisons by imposing known stem migration on a stem-bone model. Precision was estimated in 20 comparisons based on a zero-migration model, and in 5 patients without stem loosening. Limits of the 95% tolerance intervals (TIs) for accuracy did not exceed 0.28 mm for translations and 0.20° for rotations (largest standard deviation of the signed error (SD(SE)): 0.081 mm and 0.057°). In vitro, limits of the 95% TI for precision in a clinically relevant setting (8 comparisons) were below 0.09 mm and 0.14° (largest SD(SE): 0.012 mm and 0.020°). In patients, the precision was lower, but acceptable, and dependent on CT scan resolution. CTSA allows detection of stem-bone migration with an accuracy and precision comparable to that of RSA. It could be valuable for evaluation of subtle stem loosening in clinical practice.
NASA Astrophysics Data System (ADS)
Wang, H. B.; Zhao, C. Y.; Zhang, W.; Zhan, J. W.; Yu, S. X.
2015-09-01
The Earth gravitational filed model is a kind of important dynamic model in satellite orbit computation. In recent years, several space gravity missions have obtained great success, prompting a lot of gravitational filed models to be published. In this paper, 2 classical models (JGM3, EGM96) and 4 latest models, including EIGEN-CHAMP05S, GGM03S, GOCE02S, and EGM2008 are evaluated by being employed in the precision orbit determination (POD) and prediction, based on the laser range observation of four low earth orbit (LEO) satellites, including CHAMP, GFZ-1, GRACE-A, and SWARM-A. The residual error of observation in POD is adopted to describe the accuracy of six gravitational field models. We show the main results as follows: (1) for LEO POD, the accuracies of 4 latest models (EIGEN-CHAMP05S, GGM03S, GOCE02S, and EGM2008) are at the same level, and better than those of 2 classical models (JGM3, EGM96); (2) If taking JGM3 as reference, EGM96 model's accuracy is better in most situations, and the accuracies of the 4 latest models are improved by 12%-47% in POD and 63% in prediction, respectively. We also confirm that the model's accuracy in POD is enhanced with the increasing degree and order if they are smaller than 70, and when they exceed 70 the accuracy keeps stable, and is unrelated with the increasing degree, meaning that the model's degree and order truncated to 70 are sufficient to meet the requirement of LEO orbit computation with centimeter level precision.
Automated microdensitometer for digitizing astronomical plates
NASA Technical Reports Server (NTRS)
Angilello, J.; Chiang, W. H.; Elmegreen, D. M.; Segmueller, A.
1984-01-01
A precision microdensitometer was built under control of an IBM S/1 time-sharing computer system. The instrument's spatial resolution is better than 20 microns. A raster scan of an area of 10x10 sq mm (500x500 raster points) takes 255 minutes. The reproducibility is excellent and the stability is good over a period of 30 hours, which is significantly longer than the time required for most scans. The intrinsic accuracy of the instrument was tested using Kodak standard filters, and it was found to be better than 3%. A comparative accuracy was tested measuring astronomical plates of galaxies for which absolute photoelectric photometry data were available. The results showed an accuracy excellent for astronomical applications.
The accuracy of the ATLAS muon X-ray tomograph
NASA Astrophysics Data System (ADS)
Avramidou, R.; Berbiers, J.; Boudineau, C.; Dechelette, C.; Drakoulakos, D.; Fabjan, C.; Grau, S.; Gschwendtner, E.; Maugain, J.-M.; Rieder, H.; Rangod, S.; Rohrbach, F.; Sbrissa, E.; Sedykh, E.; Sedykh, I.; Smirnov, Y.; Vertogradov, L.; Vichou, I.
2003-01-01
A gigantic detector, the ATLAS project, is under construction at CERN for particle physics research at the Large Hadron Collider which is to be ready by 2006. An X-ray tomograph has been developed, designed and constructed at CERN in order to control the mechanical quality of the ATLAS muon chambers. We reached a measurement accuracy of 2 μm systematic and 2 μm statistical uncertainties in the horizontal and vertical directions in the working area 220 cm (horizontal)×60 cm (vertical). Here we describe in detail the fundamental approach of the basic principle chosen to achieve such good accuracy. In order to crosscheck our precision, key results of measurements are presented.
Counter-Revolutionary Warfare: Strategy Considerations
1986-05-01
many years after that. By 1951, European production had reached or exceeded its prewar output and European markets for American goods wete expanding...goals of the US involvement in nation building are to nurture an open political system, a free market economy, and independence. If we do not build...the markets needed to benefit the American economy. Neither does government investment n the target nation’s economy more productive. Nation building
Flood Control Wild Rice River - South Branch and Felton Ditch, Minnesota.
1974-09-01
good water quality in the proposed project area except that measure- ments for certain parameters, notably heavy metals , exceed the standards for...Topography 5 Soils 6 Climate 8 Groundwater 10 Vegetation 10 Stream Resources 13 Animal Resources 15 Water Quality 16 Regional Economics 17 Watershed... sources . The advisability of low-growing shrubs and trees along the channel would also be considered. Plate 2 illustrates several possible
Area Handbook Series: Guyana and Belize: Country Studies
1993-01-01
assimi- lated to the Spanish-speaking population of Central America, fled fighting in the Yucatan or forced labor in Guatemala and settled in the...Diet & A Although the 1990 average daily nutritional intake in Guyana, 2,450 calories, exceeded the Food and Agriculture Organization | of the...purchase the food needed for an adequate diet. Also, some foods are not avail- able in sufficient supply to ensure good nutrition . Malnutrition is still
77 FR 52228 - Food Additives Permitted for Direct Addition to Food for Human Consumption; Vitamin D2
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-29
... vitamin D 2 bakers yeast as a source of vitamin D 2 and as a leavening agent in yeast-leavened baked... baked products at levels not to exceed 400 IU of vitamin D 2 per 100 g in the finished food. The specific foods identified by the petition in which the additive will be used are yeast-leavened baked goods...
Henderson, Shelley; Purdie, Colin; Michie, Caroline; Evans, Andrew; Lerski, Richard; Johnston, Marilyn; Vinnicombe, Sarah; Thompson, Alastair M
2017-11-01
To investigate whether interim changes in hetereogeneity (measured using entropy features) on MRI were associated with pathological residual cancer burden (RCB) at final surgery in patients receiving neoadjuvant chemotherapy (NAC) for primary breast cancer. This was a retrospective study of 88 consenting women (age: 30-79 years). Scanning was performed on a 3.0 T MRI scanner prior to NAC (baseline) and after 2-3 cycles of treatment (interim). Entropy was derived from the grey-level co-occurrence matrix, on slice-matched baseline/interim T2-weighted images. Response, assessed using RCB score on surgically resected specimens, was compared statistically with entropy/heterogeneity changes and ROC analysis performed. Association of pCR within each tumour immunophenotype was evaluated. Mean entropy percent differences between examinations, by response category, were: pCR: 32.8%, RCB-I: 10.5%, RCB-II: 9.7% and RCB-III: 3.0%. Association of ultimate pCR with coarse entropy changes between baseline/interim MRI across all lesions yielded 85.2% accuracy (area under ROC curve: 0.845). Excellent sensitivity/specificity was obtained for pCR prediction within each immunophenotype: ER+: 100%/100%; HER2+: 83.3%/95.7%, TNBC: 87.5%/80.0%. Lesion T2 heterogeneity changes are associated with response to NAC using RCB scores, particularly for pCR, and can be useful across all immunophenotypes with good diagnostic accuracy. • Texture analysis provides a means of measuring lesion heterogeneity on MRI images. • Heterogeneity changes between baseline/interim MRI can be linked with ultimate pathological response. • Heterogeneity changes give good diagnostic accuracy of pCR response across all immunophenotypes. • Percentage reduction in heterogeneity is associated with pCR with good accuracy and NPV.
Budnik, Lygia Therese; Austel, Nadine; Gadau, Sabrina; Kloth, Stefan; Schubert, Jens; Jungnickel, Harald; Luch, Andreas
2017-01-01
Ambient monitoring analyses may identify potential new public health hazards such as residual levels of fumigants and industrial chemicals off gassing from products and goods shipped globally. We analyzed container air with gas chromatography coupled to mass spectrometry (TD-2D-GC-MS/FPD) and assessed whether the concentration of the volatiles benzene and 1,2-dichloroethane exceeded recommended exposure limits (REL). Products were taken from transport containers and analyzed for outgassing of volatiles. Furthermore, experimental outgassing was performed on packaging materials and textiles, to simulate the hazards tainting from globally shipped goods. The mean amounts of benzene in analyzed container air were 698-fold higher, and those of ethylene dichloride were 4.5-fold higher than the corresponding REL. More than 90% of all containers struck with toluene residues higher than its REL. For 1,2-dichloroethane 53% of containers, transporting shoes exceeded the REL. In standardized experimental fumigation of various products, outgassing of 1,2-dichloroethane under controlled laboratory conditions took up to several months. Globally produced transported products tainted with toxic industrial chemicals may contribute to the mixture of volatiles in indoor air as they are likely to emit for a long period. These results need to be taken into account for further evaluation of safety standards applying to workers and consumers.
Moghadam, Manije; Salavati, Mahyar; Sahaf, Robab; Rassouli, Maryam; Moghadam, Mojgan; Kamrani, Ahmad Ali Akbari
2018-03-01
After forward-backward translation, the LSS was administered to 334 Persian speaking, cognitively healthy elderly aged 60 years and over recruited through convenience sampling. To analyze the validity of the model's constructs and the relationships between the constructs, a confirmatory factor analysis followed by PLS analysis was performed. The Construct validity was further investigated by calculating the correlations between the LSS and the "Short Form Health Survey" (SF-36) subscales measuring similar and dissimilar constructs. The LSS was re-administered to 50 participants a month later to assess the reliability. For the eight-factor model of the life satisfaction construct, adequate goodness of fit between the hypothesized model and the model derived from the sample data was attained (positive and statistically significant beta coefficients, good R-squares and acceptable GoF). Construct validity was supported by convergent and discriminant validity, and correlations between the LSS and SF-36 subscales. Minimum Intraclass Correlation Coefficient level of 0.60 was exceeded by all subscales. Minimum level of reliability indices (Cronbach's α, composite reliability and indicator reliability) was exceeded by all subscales. The Persian-version of the Life Satisfaction Scale is a reliable and valid instrument, with psychometric properties which are consistent with the original version.
Wang, Huayin
2014-09-01
A new quantitative technique for the simultaneous quantification of the individual anthocyanins based on the pH differential method and high-performance liquid chromatography with diode array detection is proposed in this paper. The six individual anthocyanins (cyanidin 3-glucoside, cyanidin 3-rutinoside, petunidin 3-glucoside, petunidin 3-rutinoside, and malvidin 3-rutinoside) from mulberry (Morus rubra) and Liriope platyphylla were used for demonstration and validation. The elution of anthocyanins was performed using a C18 column with stepwise gradient elution and individual anthocyanins were identified by high-performance liquid chromatography with tandem mass spectrometry. Based on the pH differential method, the high-performance liquid chromatography peak areas of maximum and reference absorption wavelengths of anthocyanin extracts were conducted to quantify individual anthocyanins. The calibration curves for these anthocyanins were linear within the range of 10-5500 mg/L. The correlation coefficients (r(2)) all exceeded 0.9972, and the limits of detection were in the range of 1-4 mg/L at a signal-to-noise ratio ≥5 for these anthocyanins. The proposed quantitative analysis was reproducible with good accuracy of all individual anthocyanins ranging from 96.3 to 104.2% and relative recoveries were in the range 98.4-103.2%. The proposed technique is performed without anthocyanin standards and is a simple, rapid, accurate, and economical method to determine individual anthocyanin contents. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Magalhães, Paulo; Alves, Gilberto; Llerena, Adrián; Falcão, Amílcar
2017-09-01
The present article reports the first liquid chromatography (LC) assay for the simultaneous quantification of fluoxetine (FLU), its metabolite norfluoxetine (NFLU) and paroxetine (PAR) in human plasma, applying the microextraction by packed sorbent (MEPS) technology in sample preparation. Chromatographic analysis of FLU, NFLU and PAR was achieved in <13 min on a reverse-phase C18 column using isocratic elution and fluorescence detection (FLD). The mobile phase was composed by an aqueous solution of 25 mM sodium phosphate monobasic anhydrous and 7.5 mM di-potassium hydrogen phosphate anhydrous (pH 3.0)/acetonitrile/methanol (70:23:7, v/v/v). The detector was set at 240/312 nm for FLU, NFLU and IS and at 295/350 nm for PAR. The method showed linearity in the ranges of 20-750 ng mL-1 for FLU and NFLU, and 5-750 ng mL-1 for PAR (r2 ≥ 0.9919). The overall intra- and interday precision did not exceed 13.6% and the corresponding accuracy (bias) ranged from 0.02 to 16.7%. The method was successfully applied in the analysis of authentic plasma samples. Hence, this new MEPS/LC-FLD assay ensures robust and low-cost analyses representing, therefore, a good alternative to support therapeutic drug monitoring and clinical studies involving these antidepressant drugs. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
A Hamiltonian driven quantum-like model for overdistribution in episodic memory recollection.
NASA Astrophysics Data System (ADS)
Broekaert, Jan B.; Busemeyer, Jerome R.
2017-06-01
While people famously forget genuine memories over time, they also tend to mistakenly over-recall equivalent memories concerning a given event. The memory phenomenon is known by the name of episodic overdistribution and occurs both in memories of disjunctions and partitions of mutually exclusive events and has been tested, modeled and documented in the literature. The total classical probability of recalling exclusive sub-events most often exceeds the probability of recalling the composed event, i.e. a subadditive total. We present a Hamiltonian driven propagation for the Quantum Episodic Memory model developed by Brainerd (et al., 2015) for the episodic memory overdistribution in the experimental immediate item false memory paradigm (Brainerd and Reyna, 2008, 2010, 2015). Following the Hamiltonian method of Busemeyer and Bruza (2012) our model adds time-evolution of the perceived memory state through the stages of the experimental process based on psychologically interpretable parameters - γ_c for recollection capability of cues, κ_p for bias or description-dependence by probes and β for the average gist component in the memory state at start. With seven parameters the Hamiltonian model shows good accuracy of predictions both in the EOD-disjunction and in the EOD-subadditivity paradigm. We noticed either an outspoken preponderance of the gist over verbatim trace, or the opposite, in the initial memory state when β is real. Only for complex β a mix of both traces is present in the initial state for the EOD-subadditivity paradigm.
Kollamaram, Gayathri; Hopkins, Simon C; Glowacki, Bartek A; Croker, Denise M; Walker, Gavin M
2018-03-30
Drop-on-demand inkjet printing is a potential enabling technology both for continuous manufacturing of pharmaceuticals and for personalized medicine, but its use is often restricted to low-viscosity solutions and nano-suspensions. In the present study, a robust electromagnetic (valvejet) inkjet technology has been successfully applied to deposit prototype dosage forms from solutions with a wide range of viscosities, and from suspensions with particle sizes exceeding 2 μm. A detailed solid-state study of paracetamol, printed from a solution ink on hydroxypropyl methylcellulose (HPMC), revealed that the morphology of the substrate and its chemical interactions can have a considerable influence on polymorphic selectivity. Paracetamol ink crystallized exclusively into form II when printed on a smooth polyethylene terephthalate substrate, and exclusively into form I when in sufficient proximity to the rough surface of the HPMC substrate to be influenced by confinement in pores and chemical interactions. The relative standard deviation in the strength of the dosage forms was <4% in all cases, for doses as low as 0.8 mg, demonstrating the accuracy and reproducibility associated with electromagnetic inkjet technology. Good adhesion of indomethacin on HPMC was achieved using a suspension ink with hydroxypropyl cellulose, but not on an alternative polyethylene terephthalate substrate, emphasising the need to tailor the binder to the substrate. Future work will focus on lower-dose drugs, for which dosing flexibility and fixed dose combinations are of particular interest. Copyright © 2018 Elsevier B.V. All rights reserved.
Prieto, Ana I.; Díez-Quijada, Leticia; Campos, Alexandre; Vasconcelos, Vitor
2018-01-01
Reports on the occurrence of the cyanobacterial toxin cylindrospermopsin (CYN) have increased worldwide because of CYN toxic effects in humans and animals. If contaminated waters are used for plant irrigation, these could represent a possible CYN exposure route for humans. For the first time, a method employing solid phase extraction and quantification by ultra-performance liquid chromatography–tandem mass spectrometry (UPLC-MS/MS) of CYN was optimized in vegetables matrices such as lettuce (Lactuca sativa). The validated method showed a linear range, from 5 to 500 ng CYN g−1 of fresh weight (f.w.), and detection and quantitation limits (LOD and LOQ) of 0.22 and 0.42 ng CYN g−1 f.w., respectively. The mean recoveries ranged between 85 and 104%, and the intermediate precision from 12.7 to 14.7%. The method showed to be robust for the three different variables tested. Moreover, it was successfully applied to quantify CYN in edible lettuce leaves exposed to CYN-contaminated water (10 µg L−1), showing that the tolerable daily intake (TDI) in the case of CYN could be exceeded in elderly high consumers. The validated method showed good results in terms of sensitivity, precision, accuracy, and robustness for CYN determination in leaf vegetables such as lettuce. More studies are needed in order to prevent the risks associated with the consumption of CYN-contaminated vegetables. PMID:29389882
Study of eigenfrequencies with the help of Prony's method
NASA Astrophysics Data System (ADS)
Drobakhin, O. O.; Olevskyi, O. V.; Olevskyi, V. I.
2017-10-01
Eigenfrequencies can be crucial in the design of a construction. They define many parameters that determine limit parameters of the structure. Exceeding these values can lead to the structural failure of an object. It is especially important in the design of structures which support heavy equipment or are subjected to the forces of airflow. One of the most effective ways to acquire the frequencies' values is a computer-based numerical simulation. The existing methods do not allow to acquire the whole range of needed parameters. It is well known that Prony's method, is highly effective for the investigation of dynamic processes. Thus, it is rational to adapt Prony's method for such investigation. The Prony method has advantage in comparison with other numerical schemes because it provides the possibility to process not only the results of numerical simulation, but also real experimental data. The research was carried out for a computer model of a steel plate. The input data was obtained by using the Dassault Systems SolidWorks computer package with the Simulation add-on. We investigated the acquired input data with the help of Prony's method. The result of the numerical experiment shows that Prony's method can be used to investigate the mechanical eigenfrequencies with good accuracy. The output of Prony's method not only contains the information about values of frequencies themselves, but also contains data regarding the amplitudes, initial phases and decaying factors of any given mode of oscillation, which can also be used in engineering.
Villa, C; Gambaro, R; Mariani, E; Dorato, S
2007-07-27
The European legislation on cosmetic products has recently required the declaration of 26 compounds (24 volatile chemicals and 2 natural extracts) on the label of final products when exceeding a stipulated cut-off level. In this work a rapid reliable and specific RP-HPLC method coupled with diode array detector (DAD) has been developed for the simultaneous determination and quantification of the 24 volatile chemicals: amyl cinnamal, benzyl alcohol, cinnamyl alcohol, citral, eugenol, hydroxy-citronellal, isoeugenol, amylcinnamyl alcohol, benzyl salicylate, cinnamal, coumarin, geraniol, Lyral (hydroxy-methylpentylcyclohexene carboxaldehyde), anisyl alcohol, benzyl cinnamate, farnesol, Lilial (2-(4-tert-butylbenzyl)propionaldehyde) linalool, benzyl benzoate, citronellol, hexyl cinnamal, limonene, methylheptin carbonate, alpha-isomethyl ionone (3-methyl-4-(2,6,6-trimethyl-2-cyclohexen-1-yl)-3-buten-2-one). The 24 analytes were appropriately separated over a running time of 40 min, on a C18 column using a simple gradient elution (acetonitrile/water) with flow rate from 0.7 to 1.0 ml/min and UV acquisition at 210, 254 and 280 nm. All calibration curves showed good linearity (r2>0.99) within test ranges. The method was successfully applied to the qualitative and quantitative determination of the potential allergens in four commercial scented products, with satisfactory accuracy and precision. The results indicated that this simple and efficient method can be used for quality assessment of complex matrices such us cosmetic scented products.
Bouc-Wen hysteresis model identification using Modified Firefly Algorithm
NASA Astrophysics Data System (ADS)
Zaman, Mohammad Asif; Sikder, Urmita
2015-12-01
The parameters of Bouc-Wen hysteresis model are identified using a Modified Firefly Algorithm. The proposed algorithm uses dynamic process control parameters to improve its performance. The algorithm is used to find the model parameter values that results in the least amount of error between a set of given data points and points obtained from the Bouc-Wen model. The performance of the algorithm is compared with the performance of conventional Firefly Algorithm, Genetic Algorithm and Differential Evolution algorithm in terms of convergence rate and accuracy. Compared to the other three optimization algorithms, the proposed algorithm is found to have good convergence rate with high degree of accuracy in identifying Bouc-Wen model parameters. Finally, the proposed method is used to find the Bouc-Wen model parameters from experimental data. The obtained model is found to be in good agreement with measured data.
Using Markov Chains and Multi-Objective Optimization for Energy-Efficient Context Recognition †
Janko, Vito
2017-01-01
The recognition of the user’s context with wearable sensing systems is a common problem in ubiquitous computing. However, the typically small battery of such systems often makes continuous recognition impractical. The strain on the battery can be reduced if the sensor setting is adapted to each context. We propose a method that efficiently finds near-optimal sensor settings for each context. It uses Markov chains to simulate the behavior of the system in different configurations and the multi-objective genetic algorithm to find a set of good non-dominated configurations. The method was evaluated on three real-life datasets and found good trade-offs between the system’s energy expenditure and the system’s accuracy. One of the solutions, for example, consumed five-times less energy than the default one, while sacrificing only two percentage points of accuracy. PMID:29286301
Novel robust skylight compass method based on full-sky polarization imaging under harsh conditions.
Tang, Jun; Zhang, Nan; Li, Dalin; Wang, Fei; Zhang, Binzhen; Wang, Chenguang; Shen, Chong; Ren, Jianbin; Xue, Chenyang; Liu, Jun
2016-07-11
A novel method based on Pulse Coupled Neural Network(PCNN) algorithm for the highly accurate and robust compass information calculation from the polarized skylight imaging is proposed,which showed good accuracy and reliability especially under cloudy weather,surrounding shielding and moon light. The degree of polarization (DOP) combined with the angle of polarization (AOP), calculated from the full sky polarization image, were used for the compass information caculation. Due to the high sensitivity to the environments, DOP was used to judge the destruction of polarized information using the PCNN algorithm. Only areas with high accuracy of AOP were kept after the DOP PCNN filtering, thereby greatly increasing the compass accuracy and robustness. From the experimental results, it was shown that the compass accuracy was 0.1805° under clear weather. This method was also proven to be applicable under conditions of shielding by clouds, trees and buildings, with a compass accuracy better than 1°. With weak polarization information sources, such as moonlight, this method was shown experimentally to have an accuracy of 0.878°.
Behairy, Noha H.; Dorgham, Mohsen A.
2008-01-01
The aim of this study was to detect the accuracy of routine magnetic resonance imaging (MRI) done in different centres and its agreement with arthroscopy in meniscal and ligamentous injuries of the knee. We prospectively examined 70 patients ranging in age between 22 and 59 years. History taking, plain X-ray, clinical examination, routine MRI and arthroscopy were done for all patients. Sensitivity, specificity, accuracy, positive and negative predictive values, P value and kappa agreement measures were calculated. We found a sensitivity of 47 and 100%, specificity of 95 and 75% and accuracy of 73 and 78.5%, respectively, for the medial and lateral meniscus. A sensitivity of 77.8%, specificity of 100% and accuracy of 94% was noted for the anterior cruciate ligament (ACL). We found good kappa agreements (0.43 and 0.45) for both menisci and excellent agreement (0.84) for the ACL. MRI shows high accuracy and should be used as the primary diagnostic tool for selection of candidates for arthroscopy. Level of evidence: 4. PMID:18506445
Compound activity prediction using models of binding pockets or ligand properties in 3D
Kufareva, Irina; Chen, Yu-Chen; Ilatovskiy, Andrey V.; Abagyan, Ruben
2014-01-01
Transient interactions of endogenous and exogenous small molecules with flexible binding sites in proteins or macromolecular assemblies play a critical role in all biological processes. Current advances in high-resolution protein structure determination, database development, and docking methodology make it possible to design three-dimensional models for prediction of such interactions with increasing accuracy and specificity. Using the data collected in the Pocketome encyclopedia, we here provide an overview of two types of the three-dimensional ligand activity models, pocket-based and ligand property-based, for two important classes of proteins, nuclear and G-protein coupled receptors. For half the targets, the pocket models discriminate actives from property matched decoys with acceptable accuracy (the area under ROC curve, AUC, exceeding 84%) and for about one fifth of the targets with high accuracy (AUC > 95%). The 3D ligand property field models performed better than 95% in half of the cases. The high performance models can already become a basis of activity predictions for new chemicals. Family-wide benchmarking of the models highlights strengths of both approaches and helps identify their inherent bottlenecks and challenges. PMID:23116466
Does body mass index misclassify physically active young men.
Grier, Tyson; Canham-Chervak, Michelle; Sharp, Marilyn; Jones, Bruce H
2015-01-01
The purpose of this analysis was to determine the accuracy of age and gender adjusted BMI as a measure of body fat (BF) in U.S. Army Soldiers. BMI was calculated through measured height and weight (kg/m(2)) and body composition was determined by dual energy X-ray absorptiometry (DEXA). Linear regression was used to determine a BF prediction equation and examine the correlation between %BF and BMI. The sensitivity and specificity of BMI compared to %BF as measured by DEXA was calculated. Soldiers (n = 110) were on average 23 years old, with a BMI of 26.4, and approximately 18% BF. The correlation between BMI and %BF (R = 0.86) was strong (p < 0.01). A sensitivity of 77% and specificity of 100% were calculated when using Army age adjusted BMI thresholds. The overall accuracy in determining if a Soldier met Army BMI standards and were within the maximum allowable BF or exceeded BMI standards and were over the maximum allowable BF was 83%. Using adjusted BMI thresholds in populations where physical fitness and training are requirements of the job provides better accuracy in identifying those who are overweight or obese due to high BF.
Quantifying Safety Margin Using the Risk-Informed Safety Margin Characterization (RISMC)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grabaskas, David; Bucknor, Matthew; Brunett, Acacia
2015-04-26
The Risk-Informed Safety Margin Characterization (RISMC), developed by Idaho National Laboratory as part of the Light-Water Reactor Sustainability Project, utilizes a probabilistic safety margin comparison between a load and capacity distribution, rather than a deterministic comparison between two values, as is usually done in best-estimate plus uncertainty analyses. The goal is to determine the failure probability, or in other words, the probability of the system load equaling or exceeding the system capacity. While this method has been used in pilot studies, there has been little work conducted investigating the statistical significance of the resulting failure probability. In particular, it ismore » difficult to determine how many simulations are necessary to properly characterize the failure probability. This work uses classical (frequentist) statistics and confidence intervals to examine the impact in statistical accuracy when the number of simulations is varied. Two methods are proposed to establish confidence intervals related to the failure probability established using a RISMC analysis. The confidence interval provides information about the statistical accuracy of the method utilized to explore the uncertainty space, and offers a quantitative method to gauge the increase in statistical accuracy due to performing additional simulations.« less
[Medical residency program: perceptions of medical residents in hospitals of Lima and Callao].
Miní, Elsy; Medina, Julio; Peralta, Verónica; Rojas, Luis; Butron, Joece; Gutiérrez, Ericson L
2015-01-01
In order to rate the medical residency training program from the perceptions of residents, a structured survey, based on international literature, was applied to 228 participants. 48.2% of residents rated their training as good, 36.4% as fair and 15.4% as poor. Most of the residents had low supervision while on call, were overworked and did not have rest after being on call. Having a good annual curriculum (OR: 8.5; 95% CI: 4.1 to 7.4) and university promotion of research (OR 2.4, 95% CI: 1.1 to 5.2) were independent factors associated with higher ratings of training. In conclusion, the rating of residents about their training is mostly good, but this percentage does not exceed 50%. Training authorities could use these results to propose improvements in training programs for medical residents in Peru.
Gómez-Ordóñez, Eva; Jiménez-Escrig, Antonio; Rupérez, Pilar
2012-05-15
Biological properties of polysaccharides from seaweeds are related to their composition and structure. Many factors such as the kind of sugar, type of linkage or sulfate content of algal biopolymers exert an influence in the relationship between structure and function. Besides, the molecular weight (MW) also plays an important role. Thus, a simple, reliable and fast HPSEC method with refractive index detection was developed and optimized for the MW estimation of soluble algal polysaccharides. Chromatogram shape and repeatability of retention time was considerably improved when sodium nitrate was used instead of ultrapure water as mobile phase. Pullulan and dextran standards of different MW were used for method calibration and validation. Also, main polysaccharide standards from brown (alginate, fucoidan, laminaran) and red seaweeds (kappa- and iota-carrageenan) were used for quantification and method precision and accuracy. Relative standard deviation (RSD) of repeatability for retention time, peak areas and inter-day precision was below 0.7%, 2.5% and 2.6%, respectively, which indicated good repeatability and precision. Recoveries (96.3-109.8%) also showed its fairly good accuracy. Regarding linearity, main polysaccharide standards from brown or red seaweeds showed a highly satisfactory correlation coefficient (r>0.999). Moreover, a good sensitivity was shown, with corresponding limits of detection and quantitation in mg/mL of 0.05-0.21 and 0.16-0.31, respectively. The method was applied to the MW estimation of standard algal polysaccharides, as well as to the soluble polysaccharide fractions from the brown seaweed Saccharina latissima and the red Mastocarpus stellatus, respectively. Although distribution of molecular weight was broad, the good repeatability for retention time provided a good precision in MW estimation of polysaccharides. Water- and alkali-soluble fractions from S. latissima ranged from very high (>2400 kDa) to low MW compounds (<6 kDa); this high heterogeneity could be attributable to the complex polysaccharide composition of brown algae. Regarding M. stellatus, sulfated galactans followed a descending order of MW (>1400 kDa to <10 kDa), related to the different solubility of carrageenans in red seaweeds. In summary, the method developed allows for the molecular weight analysis of seaweed polysaccharides with very good precision, accuracy, linearity and sensitivity within a short time. Copyright © 2012 Elsevier B.V. All rights reserved.
Malaria rapid diagnostic tests in tropical climates: the need for a cool chain.
Jorgensen, Pernille; Chanthap, Lon; Rebueno, Antero; Tsuyuoka, Reiko; Bell, David
2006-05-01
Malaria control programs in endemic countries increasingly rely on early case detection and treatment at village level. The rapid diagnostic tests (RDTs) and accompanying drugs on which the success of these programs depends deteriorate to varying degrees at high temperatures. To assess the ability of health systems to maintain RDTs within manufacturers' specifications, we monitored temperatures in the delivery chain from manufacturer through to the village health worker in Cambodia and the Philippines. In both countries, storage temperatures regularly exceeded those recommended for most RDTs intended for field use, whereas temperatures during transport greatly exceeded the lower and upper limits. These results emphasize the need for good logistical planning during the introduction of point-of-care tests in tropical countries and the importance of considering the stability of diagnostic tests during procurement.
NASA Technical Reports Server (NTRS)
Klemas, V.; Bartlett, D.; Rogers, R.; Reed, L.
1974-01-01
Digital analysis of ERTS-1 imagery was used in an attempt to map and inventory the significant ecological communities of Delaware's coastal zone. Eight vegetation and land use discrimination classes were selected: (1) phragmites communis (Giant Reed grass); (2) spartina alterniflora (Salt marsh cord grass); (3) spartina patens (Salt marsh hay); (4) shallow water and exposed mud; (5) deep water (2 meters); (6) forest; (7) agriculture; and (8) exposed sand and concrete. Canonical analysis showed that classification accuracy was quite good with spartina alterniflora, exposed sand-concrete, and forested land - all discriminated with between 94% and 100% accuracy. The shallow water-mud and deep water categories were classified with accuracies of 88% and 93% respectively. Phragmites communis showed a classification accuracy of 83% with all confusion occurring with spartina patens which may be due to use of mixed stands of these species as training sets. Discrimination of spartina patens was very poor (accuracy 52%).
Evaluation of diagnostic accuracy in detecting ordered symptom statuses without a gold standard
Wang, Zheyu; Zhou, Xiao-Hua; Wang, Miqu
2011-01-01
Our research is motivated by 2 methodological problems in assessing diagnostic accuracy of traditional Chinese medicine (TCM) doctors in detecting a particular symptom whose true status has an ordinal scale and is unknown—imperfect gold standard bias and ordinal scale symptom status. In this paper, we proposed a nonparametric maximum likelihood method for estimating and comparing the accuracy of different doctors in detecting a particular symptom without a gold standard when the true symptom status had an ordered multiple class. In addition, we extended the concept of the area under the receiver operating characteristic curve to a hyper-dimensional overall accuracy for diagnostic accuracy and alternative graphs for displaying a visual result. The simulation studies showed that the proposed method had good performance in terms of bias and mean squared error. Finally, we applied our method to our motivating example on assessing the diagnostic abilities of 5 TCM doctors in detecting symptoms related to Chills disease. PMID:21209155
Karzmark, Peter; Deutsch, Gayle K
2018-01-01
This investigation was designed to determine the predictive accuracy of a comprehensive neuropsychological and brief neuropsychological test battery with regard to the capacity to perform instrumental activities of daily living (IADLs). Accuracy statistics that included measures of sensitivity, specificity, positive and negative predicted power and positive likelihood ratio were calculated for both types of batteries. The sample was drawn from a general neurological group of adults (n = 117) that included a number of older participants (age >55; n = 38). Standardized neuropsychological assessments were administered to all participants and were comprised of the Halstead Reitan Battery and portions of the Wechsler Adult Intelligence Scale-III. A comprehensive test battery yielded a moderate increase over base-rate in predictive accuracy that generalized to older individuals. There was only limited support for using a brief battery, for although sensitivity was high, specificity was low. We found that a comprehensive neuropsychological test battery provided good classification accuracy for predicting IADL capacity.
Forecasting impact injuries of unrestrained occupants in railway vehicle passenger compartments.
Xie, Suchao; Zhou, Hui
2014-01-01
In order to predict the injury parameters of the occupants corresponding to different experimental parameters and to determine impact injury indices conveniently and efficiently, a model forecasting occupant impact injury was established in this work. The work was based on finite experimental observation values obtained by numerical simulation. First, the various factors influencing the impact injuries caused by the interaction between unrestrained occupants and the compartment's internal structures were collated and the most vulnerable regions of the occupant's body were analyzed. Then, the forecast model was set up based on a genetic algorithm-back propagation (GA-BP) hybrid algorithm, which unified the individual characteristics of the back propagation-artificial neural network (BP-ANN) model and the genetic algorithm (GA). The model was well suited to studies of occupant impact injuries and allowed multiple-parameter forecasts of the occupant impact injuries to be realized assuming values for various influencing factors. Finally, the forecast results for three types of secondary collision were analyzed using forecasting accuracy evaluation methods. All of the results showed the ideal accuracy of the forecast model. When an occupant faced a table, the relative errors between the predicted and experimental values of the respective injury parameters were kept within ± 6.0 percent and the average relative error (ARE) values did not exceed 3.0 percent. When an occupant faced a seat, the relative errors between the predicted and experimental values of the respective injury parameters were kept within ± 5.2 percent and the ARE values did not exceed 3.1 percent. When the occupant faced another occupant, the relative errors between the predicted and experimental values of the respective injury parameters were kept within ± 6.3 percent and the ARE values did not exceed 3.8 percent. The injury forecast model established in this article reduced repeat experiment times and improved the design efficiency of the internal compartment's structure parameters, and it provided a new way for assessing the safety performance of the interior structural parameters in existing, and newly designed, railway vehicle compartments.
Zhang, Li; Tang, Min; Chen, Sipan; Lei, Xiaoyan; Zhang, Xiaoling; Huan, Yi
2017-12-01
This meta-analysis was undertaken to review the diagnostic accuracy of PI-RADS V2 for prostate cancer (PCa) detection with multiparametric MR (mp-MR). A comprehensive literature search of electronic databases was performed by two observers independently. Inclusion criteria were original research using the PI-RADS V2 system in reporting prostate MRI. The methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Data necessary to complete 2 × 2 contingency tables were obtained from the included studies. Thirteen studies (2,049 patients) were analysed. This is an initial meta-analysis of PI-RADs V2 and the overall diagnostic accuracy in diagnosing PCa was as follows: pooled sensitivity, 0.85 (0.78-0.91); pooled specificity, 0.71 (0.60-0.80); pooled positive likelihood ratio (LR+), 2.92 (2.09-4.09); pooled negative likelihood ratio (LR-), 0.21 (0.14-0.31); pooled diagnostic odds ratio (DOR), 14.08 (7.93-25.01), respectively. Positive predictive values ranged from 0.54 to 0.97 and negative predictive values ranged from 0.26 to 0.92. Currently available evidence indicates that PI-RADS V2 appears to have good diagnostic accuracy in patients with PCa lesions with high sensitivity and moderate specificity. However, no recommendation regarding the best threshold can be provided because of heterogeneity. • PI-RADS V2 shows good diagnostic accuracy for PCa detection. • Initially pooled specificity of PI-RADS v2 remains moderate. • PCa detection is increased by experienced radiologists. • There is currently a high heterogeneity in prostate diagnostics with MRI.
Competency-based assessment in surgeon-performed head and neck ultrasonography: A validity study.
Todsen, Tobias; Melchiors, Jacob; Charabi, Birgitte; Henriksen, Birthe; Ringsted, Charlotte; Konge, Lars; von Buchwald, Christian
2018-06-01
Head and neck ultrasonography (HNUS) increasingly is used as a point-of-care diagnostic tool by otolaryngologists. However, ultrasonography (US) is a very operator-dependent image modality. Hence, this study aimed to explore the diagnostic accuracy of surgeon-performed HNUS and to establish validity evidence for an objective structured assessment of ultrasound skills (OSAUS) used for competency-based assessment. A prospective experimental study. Six otolaryngologists and 11 US novices were included in a standardized test setup for which they had to perform focused HNUS of eight patients suspected for different head and neck lesions. Their diagnostic accuracy was calculated based on the US reports, and two blinded raters assessed the video-recorded US performance using the OSAUS scale. The otolaryngologists obtained a high diagnostic accuracy on 88% (range 63%-100%) compared to the US novices on 38% (range 0-63%); P < 0.001. The OSAUS score demonstrated good inter-case reliability (0.85) and inter-rater reliability (0.76), and significant discrimination between otolaryngologist and US novices; P < 0.001. A strong correlation between the OSAUS score and the diagnostic accuracy was found (Spearman's ρ, 0.85; P < P 0.001), and a pass/fail score was established at 2.8. Strong validity evidence supported the use of the OSAUS scale to assess HNUS competence with good reliability, significant discrimination between US competence levels, and a strong correlation of assessment score to diagnostic accuracy. An OSAUS pass/fail score was established and could be used for competence-based assessment in surgeon-performed HNUS. NA. Laryngoscope, 128:1346-1352, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Diagnostic performance of a Lattice Boltzmann-based method for CT-based fractional flow reserve.
Giannopoulos, Andreas A; Tang, Anji; Ge, Yin; Cheezum, Michael K; Steigner, Michael L; Fujimoto, Shinichiro; Kumamaru, Kanako K; Chiappino, Dante; Della Latta, Daniele; Berti, Sergio; Chiappino, Sara; Rybicki, Frank J; Melchionna, Simone; Mitsouras, Dimitrios
2018-02-20
Fractional flow reserve (FFR) estimated from coronary computed tomography angiography (CT-FFR) offers non-invasive detection of lesion-specific ischaemia. We aimed to develop and validate a fast CT-FFR algorithm utilising the Lattice Boltzmann method for blood flow simulation (LBM CT-FFR). Sixty-four patients with clinically indicated CTA and invasive FFR measurement from three institutions were retrospectively analysed. CT-FFR was performed using an onsite tool interfacing with a commercial Lattice Boltzmann fluid dynamics cloud-based platform. Diagnostic accuracy of LBM CT-FFR ≤0.8 and percent diameter stenosis >50% by CTA to detect invasive FFR ≤0.8 were compared using area under the receiver operating characteristic curve (AUC). Sixty patients successfully underwent LBM CT-FFR analysis; 29 of 73 lesions in 69 vessels had invasive FFR ≤0.8. Total time to perform LBM CT-FFR was 40±10 min. Compared to invasive FFR, LBM CT-FFR had good correlation (r=0.64), small bias (0.009) and good limits of agreement (-0.223 to 0.206). The AUC of LBM CT-FFR (AUC=0.894, 95% confidence interval [CI]: 0.792-0.996) was significantly higher than CTA (AUC=0.685, 95% CI: 0.576-0.794) to detect FFR ≤0.8 (p=0.0021). Per-lesion specificity, sensitivity, and accuracy of LBM CT-FFR were 97.7%, 79.3%, and 90.4%, respectively. LBM CT-FFR has very good diagnostic accuracy to detect lesion-specific ischaemia (FFR ≤0.8) and can be performed in less than one hour.
Efficient differentially private learning improves drug sensitivity prediction.
Honkela, Antti; Das, Mrinal; Nieminen, Arttu; Dikmen, Onur; Kaski, Samuel
2018-02-06
Users of a personalised recommendation system face a dilemma: recommendations can be improved by learning from data, but only if other users are willing to share their private information. Good personalised predictions are vitally important in precision medicine, but genomic information on which the predictions are based is also particularly sensitive, as it directly identifies the patients and hence cannot easily be anonymised. Differential privacy has emerged as a potentially promising solution: privacy is considered sufficient if presence of individual patients cannot be distinguished. However, differentially private learning with current methods does not improve predictions with feasible data sizes and dimensionalities. We show that useful predictors can be learned under powerful differential privacy guarantees, and even from moderately-sized data sets, by demonstrating significant improvements in the accuracy of private drug sensitivity prediction with a new robust private regression method. Our method matches the predictive accuracy of the state-of-the-art non-private lasso regression using only 4x more samples under relatively strong differential privacy guarantees. Good performance with limited data is achieved by limiting the sharing of private information by decreasing the dimensionality and by projecting outliers to fit tighter bounds, therefore needing to add less noise for equal privacy. The proposed differentially private regression method combines theoretical appeal and asymptotic efficiency with good prediction accuracy even with moderate-sized data. As already the simple-to-implement method shows promise on the challenging genomic data, we anticipate rapid progress towards practical applications in many fields. This article was reviewed by Zoltan Gaspari and David Kreil.
The Strong Lensing Time Delay Challenge (2014)
NASA Astrophysics Data System (ADS)
Liao, Kai; Dobler, G.; Fassnacht, C. D.; Treu, T.; Marshall, P. J.; Rumbaugh, N.; Linder, E.; Hojjati, A.
2014-01-01
Time delays between multiple images in strong lensing systems are a powerful probe of cosmology. At the moment the application of this technique is limited by the number of lensed quasars with measured time delays. However, the number of such systems is expected to increase dramatically in the next few years. Hundred such systems are expected within this decade, while the Large Synoptic Survey Telescope (LSST) is expected to deliver of order 1000 time delays in the 2020 decade. In order to exploit this bounty of lenses we needed to make sure the time delay determination algorithms have sufficiently high precision and accuracy. As a first step to test current algorithms and identify potential areas for improvement we have started a "Time Delay Challenge" (TDC). An "evil" team has created realistic simulated light curves, to be analyzed blindly by "good" teams. The challenge is open to all interested parties. The initial challenge consists of two steps (TDC0 and TDC1). TDC0 consists of a small number of datasets to be used as a training template. The non-mandatory deadline is December 1 2013. The "good" teams that complete TDC0 will be given access to TDC1. TDC1 consists of thousands of lightcurves, a number sufficient to test precision and accuracy at the subpercent level, necessary for time-delay cosmography. The deadline for responding to TDC1 is July 1 2014. Submissions will be analyzed and compared in terms of predefined metrics to establish the goodness-of-fit, efficiency, precision and accuracy of current algorithms. This poster describes the challenge in detail and gives instructions for participation.
Fukuyama, Atsushi; Isoda, Haruo; Morita, Kento; Mori, Marika; Watanabe, Tomoya; Ishiguro, Kenta; Komori, Yoshiaki; Kosugi, Takafumi
2017-01-01
Introduction: We aim to elucidate the effect of spatial resolution of three-dimensional cine phase contrast magnetic resonance (3D cine PC MR) imaging on the accuracy of the blood flow analysis, and examine the optimal setting for spatial resolution using flow phantoms. Materials and Methods: The flow phantom has five types of acrylic pipes that represent human blood vessels (inner diameters: 15, 12, 9, 6, and 3 mm). The pipes were fixed with 1% agarose containing 0.025 mol/L gadolinium contrast agent. A blood-mimicking fluid with human blood property values was circulated through the pipes at a steady flow. Magnetic resonance (MR) images (three-directional phase images with speed information and magnitude images for information of shape) were acquired using the 3-Tesla MR system and receiving coil. Temporal changes in spatially-averaged velocity and maximum velocity were calculated using hemodynamic analysis software. We calculated the error rates of the flow velocities based on the volume flow rates measured with a flowmeter and examined measurement accuracy. Results: When the acrylic pipe was the size of the thoracicoabdominal or cervical artery and the ratio of pixel size for the pipe was set at 30% or lower, spatially-averaged velocity measurements were highly accurate. When the pixel size ratio was set at 10% or lower, maximum velocity could be measured with high accuracy. It was difficult to accurately measure maximum velocity of the 3-mm pipe, which was the size of an intracranial major artery, but the error for spatially-averaged velocity was 20% or less. Conclusions: Flow velocity measurement accuracy of 3D cine PC MR imaging for pipes with inner sizes equivalent to vessels in the cervical and thoracicoabdominal arteries is good. The flow velocity accuracy for the pipe with a 3-mm-diameter that is equivalent to major intracranial arteries is poor for maximum velocity, but it is relatively good for spatially-averaged velocity. PMID:28132996
Kim, Jae-Hong; Kim, Ki-Baek; Kim, Woong-Chul; Kim, Ji-Hwan; Kim, Hae-Young
2014-03-01
This study aimed to evaluate the accuracy and precision of polyurethane (PUT) dental arch models fabricated using a three-dimensional (3D) subtractive rapid prototyping (RP) method with an intraoral scanning technique by comparing linear measurements obtained from PUT models and conventional plaster models. Ten plaster models were duplicated using a selected standard master model and conventional impression, and 10 PUT models were duplicated using the 3D subtractive RP technique with an oral scanner. Six linear measurements were evaluated in terms of x, y, and z-axes using a non-contact white light scanner. Accuracy was assessed using mean differences between two measurements, and precision was examined using four quantitative methods and the Bland-Altman graphical method. Repeatability was evaluated in terms of intra-examiner variability, and reproducibility was assessed in terms of inter-examiner and inter-method variability. The mean difference between plaster models and PUT models ranged from 0.07 mm to 0.33 mm. Relative measurement errors ranged from 2.2% to 7.6% and intraclass correlation coefficients ranged from 0.93 to 0.96, when comparing plaster models and PUT models. The Bland-Altman plot showed good agreement. The accuracy and precision of PUT dental models for evaluating the performance of oral scanner and subtractive RP technology was acceptable. Because of the recent improvements in block material and computerized numeric control milling machines, the subtractive RP method may be a good choice for dental arch models.
Li, Xueyan; Kan, Xianwen
2018-04-30
In this study, a ratiometric strategy-based electrochemical sensor was developed by electropolymerization of thionine (THI) and β-cyclodextrin (β-CD) composite films on a glassy carbon electrode surface for imidacloprid (IMI) detection. THI played the role of an inner reference element to provide a built-in correction. In addition, the modified β-CD showed good selective enrichment for IMI to improve the sensitivity and anti-interference ability of the sensor. The current ratio between IMI and THI was calculated as the detected signal for IMI sensing. Compared with common single-signal sensing, the proposed ratiometric strategy showed a higher linear range and a lower limit of detection of 4.0 × 10-8-1.0 × 10-5 mol L-1 and 1.7 × 10-8 mol L-1, respectively, for IMI detection. On the other hand, the ratiometric strategy endowed the sensor with good accuracy, reproducibility, and stability. The sensor was also used for IMI determination in real samples with satisfactory results. The simple, effective, and reliable way reported in this study can be further used to prepare ratiometric strategy-based electrochemical sensors for the selective and sensitive detection of other compounds with good accuracy and stability.
Manzanilla-Pech, C I V; Veerkamp, R F; de Haas, Y; Calus, M P L; Ten Napel, J
2017-11-01
Given the interest of including dry matter intake (DMI) in the breeding goal, accurate estimated breeding values (EBV) for DMI are needed, preferably for separate lactations. Due to the limited amount of records available on DMI, 2 main approaches have been suggested to compute those EBV: (1) the inclusion of predictor traits, such as fat- and protein-corrected milk (FPCM) and live weight (LW), and (2) the addition of genomic information of animals using what is called genomic prediction. Recently, several methodologies to estimate EBV utilizing genomic information (EBV) have become available. In this study, a new method known as single-step ridge-regression BLUP (SSRR-BLUP) is suggested. The SSRR-BLUP method does not have an imposed limit on the number of genotyped animals, as the commonly used methods do. The objective of this study was to estimate genetic parameters using a relatively large data set with DMI records, as well as compare the accuracies of the EBV for DMI. These accuracies were obtained using 4 different methods: BLUP (using pedigree for all animals with phenotypes), genomic BLUP (GBLUP; only for genotyped animals), single-step GBLUP (SS-GBLUP), and SSRR-BLUP (for genotyped and nongenotyped animals). Records from different lactations, with or without predictor traits (FPCM and LW), were used in the model. Accuracies of EBV for DMI (defined as the correlation between the EBV and pre-adjusted DMI phenotypes divided by the average accuracy of those phenotypes) ranged between 0.21 and 0.38 across methods and scenarios. Accuracies of EBV for DMI using BLUP were the lowest accuracies obtained across methods. Meanwhile, accuracies of EBV for DMI were similar in SS-GBLUP and SSRR-BLUP, and lower for the GBLUP method. Hence, SSRR-BLUP could be used when the number of genotyped animals is large, avoiding the construction of the inverse genomic relationship matrix. Adding information on DMI from different lactations in the reference population gave higher accuracies in comparison when only lactation 1 was included. Finally, no benefit was obtained by adding information on predictor traits to the reference population when DMI was already included. However, in the absence of DMI records, having records on FPCM and LW from different lactations is a good way to obtain EBV with a relatively good accuracy. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Guha, Daipayan; Jakubovic, Raphael; Gupta, Shaurya; Yang, Victor X. D.
2017-02-01
Computer-assisted navigation (CAN) may guide spinal surgeries, reliably reducing screw breach rates. Definitions of screw breach, if reported, vary widely across studies. Absolute quantitative error is theoretically a more precise and generalizable metric of navigation accuracy, but has been computed variably and reported in fewer than 25% of clinical studies of CAN-guided pedicle screw accuracy. We reviewed a prospectively-collected series of 209 pedicle screws placed with CAN guidance to characterize the correlation between clinical pedicle screw accuracy, based on postoperative imaging, and absolute quantitative navigation accuracy. We found that acceptable screw accuracy was achieved for significantly fewer screws based on 2mm grade vs. Heary grade, particularly in the lumbar spine. Inter-rater agreement was good for the Heary classification and moderate for the 2mm grade, significantly greater among radiologists than surgeon raters. Mean absolute translational/angular accuracies were 1.75mm/3.13° and 1.20mm/3.64° in the axial and sagittal planes, respectively. There was no correlation between clinical and absolute navigation accuracy, in part because surgeons appear to compensate for perceived translational navigation error by adjusting screw medialization angle. Future studies of navigation accuracy should therefore report absolute translational and angular errors. Clinical screw grades based on post-operative imaging, if reported, may be more reliable if performed in multiple by radiologist raters.
Arsenic exposure in drinking water: an unrecognized health threat in Peru
Sima, Laura; Arias, M Helena Jahuira; Mihalic, Jana; Cabrera, Lilia Z; Danz, David; Checkley, William; Gilman, Robert H
2014-01-01
Abstract Objective To assess the extent of arsenic contamination of groundwater and surface water in Peru and, to evaluate the accuracy of the Arsenic Econo-Quick™ (EQ) kit for measuring water arsenic concentrations in the field. Methods Water samples were collected from 151 water sources in 12 districts of Peru, and arsenic concentrations were measured in the laboratory using inductively-coupled plasma mass spectrometry. The EQ field kit was validated by comparing a subset of 139 water samples analysed by laboratory measurements and the EQ kit. Findings In 86% (96/111) of the groundwater samples, arsenic exceeded the 10 µg/l arsenic concentration guideline given by the World Health Organization (WHO) for drinking water. In 56% (62/111) of the samples, it exceeded the Bangladeshi threshold of 50 µg/l; the mean concentration being 54.5 µg/l (range: 0.1–93.1). In the Juliaca and Caracoto districts, in 96% (27/28) of groundwater samples arsenic was above the WHO guideline; and in water samples collected from the section of the Rímac river running through Lima, all had arsenic concentrations exceeding the WHO limit. When validated against laboratory values, the EQ kit correctly identified arsenic contamination relative to the guideline in 95% (106/111) of groundwater and in 68% (19/28) of surface water samples. Conclusion In several districts of Peru, drinking water shows widespread arsenic contamination, exceeding the WHO arsenic guideline. This poses a public health threat requiring further investigation and action. For groundwater samples, the EQ kit performed well relative to the WHO arsenic limit and therefore could provide a vital tool for water arsenic surveillance. PMID:25177071
Diagnostic accuracy of language sample measures with Persian-speaking preschool children.
Kazemi, Yalda; Klee, Thomas; Stringer, Helen
2015-04-01
This study examined the diagnostic accuracy of selected language sample measures (LSMs) with Persian-speaking children. A pre-accuracy study followed by phase I and II studies are reported. Twenty-four Persian-speaking children, aged 42 to 54 months, with primary language impairment (PLI) were compared to 27 age-matched children without PLI on a set of measures derived from play-based, conversational language samples. Results showed that correlations between age and LSMs were not statistically significant in either group of children. However, a majority of LSMs differentiated children with and without PLI at the group level (phase I), while three of the measures exhibited good diagnostic accuracy at the level of the individual (phase II). We conclude that general LSMs are promising for distinguishing between children with and without PLI. Persian-specific measures are mainly helpful in identifying children without language impairment while their ability to identify children with PLI is poor.
Acquisition and Retention of Sterile Compounding Accuracy Skills
Brown, Michael C.; Valdovinos, Katie; Zavala, Pedro J.
2017-01-01
Objective. To determine the accuracy of dose of pharmacy students’ parenteral sterile preparation skills and to measure pharmacy students’ skill retention 1.5 years later. Methods. An exercise was designed to assess each student’s accuracy in compounding a sterile preparation with the correct potency during a second and then third year course. Results. Initially, the mean (standard deviation) of 141 students’ compounded preparation dose was not significantly different than the desired dose. Additionally, 91.5% of products were within 10% of the desired dose. In the follow-up activity the next academic year, the mean dose was not significantly different than the original compounded dose. Similarly 92.9% were within 10% of the desired dose. Conclusion. Students’ overall accuracy of sterile compounding was good initially and well-retained more than a year later, with more than 90% of students being within 10% of the desired dose in both courses. PMID:28970616
NASA Technical Reports Server (NTRS)
Armoundas, A. A.; Rosenbaum, D. S.; Ruskin, J. N.; Garan, H.; Cohen, R. J.
1998-01-01
OBJECTIVE: To investigate the accuracy of signal averaged electrocardiography (SAECG) and measurement of microvolt level T wave alternans as predictors of susceptibility to ventricular arrhythmias. DESIGN: Analysis of new data from a previously published prospective investigation. SETTING: Electrophysiology laboratory of a major referral hospital. PATIENTS AND INTERVENTIONS: 43 patients, not on class I or class III antiarrhythmic drug treatment, undergoing invasive electrophysiological testing had SAECG and T wave alternans measurements. The SAECG was considered positive in the presence of one (SAECG-I) or two (SAECG-II) of three standard criteria. T wave alternans was considered positive if the alternans ratio exceeded 3.0. MAIN OUTCOME MEASURES: Inducibility of sustained ventricular tachycardia or fibrillation during electrophysiological testing, and 20 month arrhythmia-free survival. RESULTS: The accuracy of T wave alternans in predicting the outcome of electrophysiological testing was 84% (p < 0.0001). Neither SAECG-I (accuracy 60%; p < 0.29) nor SAECG-II (accuracy 71%; p < 0.10) was a statistically significant predictor of electrophysiological testing. SAECG, T wave alternans, electrophysiological testing, and follow up data were available in 36 patients while not on class I or III antiarrhythmic agents. The accuracy of T wave alternans in predicting the outcome of arrhythmia-free survival was 86% (p < 0.030). Neither SAECG-I (accuracy 65%; p < 0.21) nor SAECG-II (accuracy 71%; p < 0.48) was a statistically significant predictor of arrhythmia-free survival. CONCLUSIONS: T wave alternans was a highly significant predictor of the outcome of electrophysiological testing and arrhythmia-free survival, while SAECG was not a statistically significant predictor. Although these results need to be confirmed in prospective clinical studies, they suggest that T wave alternans may serve as a non-invasive probe for screening high risk populations for malignant ventricular arrhythmias.
Comparing Features for Classification of MEG Responses to Motor Imagery
Halme, Hanna-Leena; Parkkonen, Lauri
2016-01-01
Background Motor imagery (MI) with real-time neurofeedback could be a viable approach, e.g., in rehabilitation of cerebral stroke. Magnetoencephalography (MEG) noninvasively measures electric brain activity at high temporal resolution and is well-suited for recording oscillatory brain signals. MI is known to modulate 10- and 20-Hz oscillations in the somatomotor system. In order to provide accurate feedback to the subject, the most relevant MI-related features should be extracted from MEG data. In this study, we evaluated several MEG signal features for discriminating between left- and right-hand MI and between MI and rest. Methods MEG was measured from nine healthy participants imagining either left- or right-hand finger tapping according to visual cues. Data preprocessing, feature extraction and classification were performed offline. The evaluated MI-related features were power spectral density (PSD), Morlet wavelets, short-time Fourier transform (STFT), common spatial patterns (CSP), filter-bank common spatial patterns (FBCSP), spatio—spectral decomposition (SSD), and combined SSD+CSP, CSP+PSD, CSP+Morlet, and CSP+STFT. We also compared four classifiers applied to single trials using 5-fold cross-validation for evaluating the classification accuracy and its possible dependence on the classification algorithm. In addition, we estimated the inter-session left-vs-right accuracy for each subject. Results The SSD+CSP combination yielded the best accuracy in both left-vs-right (mean 73.7%) and MI-vs-rest (mean 81.3%) classification. CSP+Morlet yielded the best mean accuracy in inter-session left-vs-right classification (mean 69.1%). There were large inter-subject differences in classification accuracy, and the level of the 20-Hz suppression correlated significantly with the subjective MI-vs-rest accuracy. Selection of the classification algorithm had only a minor effect on the results. Conclusions We obtained good accuracy in sensor-level decoding of MI from single-trial MEG data. Feature extraction methods utilizing both the spatial and spectral profile of MI-related signals provided the best classification results, suggesting good performance of these methods in an online MEG neurofeedback system. PMID:27992574
Polyimide Composites Based on Asymmetric Dianhydrides (a-ODPA vs a-BPDA)
NASA Technical Reports Server (NTRS)
Chuang, Kathy C.; Criss, James M.; Mintz, Eric A.
2009-01-01
RTM Resins based on a-ODPA and a-BPDA with kinked diamines exhibit low-melt viscosity (approximately 10 poise). Composites made from a-ODPA resins (T(sub g) = 265-330 C) by RTM display good mechanical properties at 288 C (550 F), but soften at 315 C (600 F). Composites of RTM370 based on a-BPDA retain excellent mechanical properties at 315 C, exceeding BMI-5270-1 capability.
Agroterrorism: Threats and Preparedness
2004-08-13
chickens exceeded 8.5 billion birds.7 Cattle are the most widely distributed given the prevalence of small cow-calf herds throughout the country and pockets...prices could rise for those products. Such goods may include substitutes for the food that was the target of the attack (e.g., chicken instead of beef...spoilage if delays arise, or that certain perishables (especially from Mexico ) are not harvested or loaded onto trucks before the two-hour notification
Agroterrorism: Threats and Preparedness
2005-02-04
included 95 million cattle and calves, 60 million hogs and pigs. Farm sales of broilers and other meat-type chickens exceeded 8.5 billion birds.6...goods may include substitutes for the food that was the target of the attack (e.g., chicken instead of beef), or product that can be certified not to come...perishable imports are subject to increased spoilage if delays arise, or that certain perishables (especially from Mexico ) are not harvested or loaded
1936-04-01
indicate that good welds by these two last named processes give excellent impact results. Welds subjected to extremely low or high temperature merit...variation with temperature of the ratio of shear to tensile stress developed in the Izod or Charpy test, falls from a high to an exceedingly low value...and Larsen also showed that high nitrogen or oxygen content shifted the "zone of transition" to higher temperatures , and that normalizing shifted the