Zhang, Guangwu; Wang, Fuzhong; Huang, Zhixiong; Dai, Jing; Shi, Minxian
2016-08-24
Montmorillonite (MMT) was added to silicone rubber (SR) to improve the ablation resistance of the silicone. Following this, different quantities of silicon carbide whiskers (SiCw) were incorporated into the MMT/SR to yield a hybrid, ablative composite. The tensile strength and elongation at break of the composite increased after the addition of MMT. The ablation test results showed that MMT helped to form a covering layer by bonding with the silica and other components on the ablated surface. The linear and mass ablation rates exhibited decreases of 22.5% and 18.2%, respectively, in comparison to a control sample. After further incorporation of SiCw as the second filler, the resulting composites exhibited significantly higher tensile strength and ablation resistance, but not particularly lower elongation at break in comparison to the control sample. The SiCw/MMT fillers were beneficial in forming a dense and compact covering layer that delayed the heat and oxygen diffusion into the inner layers, which improved the ablation properties effectively. The remaining whiskers acted as a micro skeleton to maintain the composite's char strength. Compared to the control sample, the linear and mass ablation rates of the composite after incorporating 6 phr SiCw and 10 phr MMT decreased by 59.2% and 43.6%, respectively. These experimental results showed that the fabricated composites exhibited outstanding mechanical properties and excellent ablation resistance.
Zhang, Guangwu; Wang, Fuzhong; Huang, Zhixiong; Dai, Jing; Shi, Minxian
2016-01-01
Montmorillonite (MMT) was added to silicone rubber (SR) to improve the ablation resistance of the silicone. Following this, different quantities of silicon carbide whiskers (SiCw) were incorporated into the MMT/SR to yield a hybrid, ablative composite. The tensile strength and elongation at break of the composite increased after the addition of MMT. The ablation test results showed that MMT helped to form a covering layer by bonding with the silica and other components on the ablated surface. The linear and mass ablation rates exhibited decreases of 22.5% and 18.2%, respectively, in comparison to a control sample. After further incorporation of SiCw as the second filler, the resulting composites exhibited significantly higher tensile strength and ablation resistance, but not particularly lower elongation at break in comparison to the control sample. The SiCw/MMT fillers were beneficial in forming a dense and compact covering layer that delayed the heat and oxygen diffusion into the inner layers, which improved the ablation properties effectively. The remaining whiskers acted as a micro skeleton to maintain the composite’s char strength. Compared to the control sample, the linear and mass ablation rates of the composite after incorporating 6 phr SiCw and 10 phr MMT decreased by 59.2% and 43.6%, respectively. These experimental results showed that the fabricated composites exhibited outstanding mechanical properties and excellent ablation resistance. PMID:28773846
Hu, Ping; Gui, Kaixuan; Yang, Yang; Dong, Shun; Zhang, Xinghong
2013-01-01
The ablation and oxidation of ZrB2-based ultra high temperature ceramic (UHTC) composites containing 10%, 15% and 30% v/v SiC were tested under different heat fluxes in a high frequency plasma wind tunnel. Performance was significantly affected by the surface temperature, which was strongly dependent on the composition. Composites containing 10% SiC showed the highest surface temperature (>2300 °C) and underwent a marked degradation under both conditions. In contrast, composites with 30% SiC exhibited the lowest surface temperature (<2000 °C) and demonstrated excellent ablation resistance. The surface temperature of UHTCs in aerothermal testing was closely associated with the dynamic evolution of the surface and bulk oxide properties, especially for the change in chemical composition on the exposed surface, which was strongly dependent on the material composition and testing parameters (i.e., heat flux, enthalpy, pressure and test time), and in turn affected its oxidation performance. PMID:28809239
Hu, Ping; Gui, Kaixuan; Yang, Yang; Dong, Shun; Zhang, Xinghong
2013-04-29
The ablation and oxidation of ZrB₂-based ultra high temperature ceramic (UHTC) composites containing 10%, 15% and 30% v/v SiC were tested under different heat fluxes in a high frequency plasma wind tunnel. Performance was significantly affected by the surface temperature, which was strongly dependent on the composition. Composites containing 10% SiC showed the highest surface temperature (>2300 °C) and underwent a marked degradation under both conditions. In contrast, composites with 30% SiC exhibited the lowest surface temperature (<2000 °C) and demonstrated excellent ablation resistance. The surface temperature of UHTCs in aerothermal testing was closely associated with the dynamic evolution of the surface and bulk oxide properties, especially for the change in chemical composition on the exposed surface, which was strongly dependent on the material composition and testing parameters ( i.e. , heat flux, enthalpy, pressure and test time), and in turn affected its oxidation performance.
Numerical Study on Density Gradient Carbon-Carbon Composite for Vertical Launching System
NASA Astrophysics Data System (ADS)
Yoon, Jin-Young; Kim, Chun-Gon; Lim, Juhwan
2018-04-01
This study presents new carbon-carbon (C/C) composite that has a density gradient within single material, and estimates its heat conduction performance by a numerical method. To address the high heat conduction of a high-density C/C, which can cause adhesion separation in the steel structures of vertical launching systems, density gradient carbon-carbon (DGCC) composite is proposed due to its exhibiting low thermal conductivity as well as excellent ablative resistance. DGCC is manufactured by hybridizing two different carbonization processes into a single carbon preform. One part exhibits a low density using phenolic resin carbonization to reduce heat conduction, and the other exhibits a high density using thermal gradient-chemical vapor infiltration for excellent ablative resistance. Numerical analysis for DGCC is performed with a heat conduction problem, and internal temperature distributions are estimated by the forward finite difference method. Material properties of the transition density layer, which is inevitably formed during DGCC manufacturing, are assumed to a combination of two density layers for numerical analysis. By comparing numerical results with experimental data, we validate that DGCC exhibits a low thermal conductivity, and it can serve as highly effective ablative material for vertical launching systems.
NASA Technical Reports Server (NTRS)
Connell, John; Palmieri, Frank; Truong, Hieu; Ochoa, Ozden; Lagoudas, Dimitris
2015-01-01
Hybrid composite laminates that contain alternating layers of titanium alloys and carbon fabric reinforced polyimide matrix composites (PMC) are excellent candidates for light-weight, high-temperature structural materials for high-speed aerospace vehicles. The delamination resistance of the hybrid titanium-PMC interface is of crucial consideration for structural integrity during service. Here, we report the first investigations on the use of laser ablation in combination with sol-gel treatment technique on Ti/NiTi foil surfaces in co-cured hybrid polyimide matrix composite laminates. Mode-I and mode-II fracture toughness of the hybrid Ti/NiTi-PMC interface as a function of temperature were determined via experimental testing and finite element analysis.
NASA Astrophysics Data System (ADS)
Wu, Baoye; Liu, Peng; Wang, Xizhao; Zhang, Fei; Deng, Leimin; Duan, Jun; Zeng, Xiaoyan
2018-05-01
Due to excellent properties, Cr12MoV mold steel, 9Cr18 stainless steel and H13A cemented carbide are widely used in industry. In this paper, the effect of absorption of laser light on ablation efficiency and roughness have been studied using a picosecond pulse Nd:YVO4 laser. The experimental results reveal that laser wavelength, original surface roughness and chemical composition play an important role in controlling ablation efficiency and roughness. Firstly, higher ablation efficiency with lower surface roughness is achieved on the ablation of 9Cr18 at 532, comparing with 1064 nm. Secondly, the ablation efficiency increases while the Ra of the ablated region decreases with the decrease of original surface roughness on ablation of Cr12MoV mold steel at 532 nm. Thirdly, the ablation efficiency of H13A cemented carbide is much higher than 9Cr18 stainless steel and Cr12MoV mold steel at 1064 nm. Scanning electron microscopy images reveals the formation of pores on the surface of 9Cr18 stainless steel and Cr12MoV mold steel at 532 nm while no pores are formed at 1064 nm. As to H13A cemented carbide, worm-like structure is formed at 1064 nm. The synergetic effects of the heat accumulation, plasma shielding and ablation threshold on laser ablation efficiency and machining quality were analyzed and discussed systematically in this paper.
Assessment of liver ablation using cone beam computed tomography.
Abdel-Rehim, Mohamed; Ronot, Maxime; Sibert, Annie; Vilgrain, Valérie
2015-01-14
To investigate the feasibility and accuracy of cone beam computed tomography (CBCT) in assessing the ablation zone after liver tumor ablation. Twenty-three patients (17 men and 6 women, range: 45-85 years old, mean age 65 years) with malignant liver tumors underwent ultrasound-guided percutaneous tumor ablation [radiofrequency (n = 14), microwave (n = 9)] followed by intravenous contrast-enhanced CBCT. Baseline multidetector computed tomography (MDCT) and peri-procedural CBCT images were compared. CBCT image quality was assessed as poor, good, or excellent. Image fusion was performed to assess tumor coverage, and quality of fusion was rated as bad, good, or excellent. Ablation zone volumes on peri-procedural CBCT and post-procedural MDCT were compared using the non-parametric paired Wilcoxon t-test. Rate of primary ablation effectiveness was 100%. There were no complications related to ablation. Local tumor recurrence and new liver tumors were found 3 mo after initial treatment in one patient (4%). The ablation zone was identified in 21/23 (91.3%) patients on CBCT. The fusion of baseline MDCT and peri-procedural CBCT images was feasible in all patients and showed satisfactory tumor coverage (at least 5-mm margin). CBCT image quality was poor, good, and excellent in 2 (9%), 8 (35%), and 13 (56%), patients respectively. Registration quality between peri-procedural CBCT and post-procedural MDCT images was good to excellent in 17/23 (74%) patients. The median ablation volume on peri-procedural CBCT and post-procedural MDCT was 30 cm(3) (range: 4-95 cm(3)) and 30 cm(3) (range: 4-124 cm(3)), respectively (P-value > 0.2). There was a good correlation (r = 0.79) between the volumes of the two techniques. Contrast-enhanced CBCT after tumor ablation of the liver allows early assessment of the ablation zone.
Correard, Florian; Maximova, Ksenia; Estève, Marie-Anne; Villard, Claude; Roy, Myriam; Al-Kattan, Ahmed; Sentis, Marc; Gingras, Marc; Kabashin, Andrei V; Braguer, Diane
2014-01-01
Due to excellent biocompatibility, chemical stability, and promising optical properties, gold nanoparticles (Au-NPs) are the focus of research and applications in nanomedicine. Au-NPs prepared by laser ablation in aqueous biocompatible solutions present an essentially novel object that is unique in avoiding any residual toxic contaminant. This paper is conceived as the next step in development of laser-ablated Au-NPs for future in vivo applications. The aim of the study was to assess the safety, uptake, and biological behavior of laser-synthesized Au-NPs prepared in water or polymer solutions in human cell lines. Our results showed that laser ablation allows the obtaining of stable and monodisperse Au-NPs in water, polyethylene glycol, and dextran solutions. The three types of Au-NPs were internalized in human cell lines, as shown by transmission electron microscopy. Biocompatibility and safety of Au-NPs were demonstrated by analyzing cell survival and cell morphology. Furthermore, incubation of the three Au-NPs in serum-containing culture medium modified their physicochemical characteristics, such as the size and the charge. The composition of the protein corona adsorbed on Au-NPs was investigated by mass spectrometry. Regarding composition of complement C3 proteins and apolipoproteins, Au-NPs prepared in dextran solution appeared as a promising drug carrier. Altogether, our results revealed the safety of laser-ablated Au-NPs in human cell lines and support their use for theranostic applications. PMID:25473280
Ablation properties of carbon/carbon composites with tungsten carbide
NASA Astrophysics Data System (ADS)
Yin, Jian; Zhang, Hongbo; Xiong, Xiang; Huang, Baiyun; Zuo, Jinlv
2009-02-01
The ablation properties and morphologies of carbon/carbon (C/C) composites with tungsten carbide (WC) filaments were investigated by ablation test on an arc heater and scanning electron microscopy. And the results were compared with those without tungsten carbide (WC) filaments tested under the same conditions. It shows that there is a big difference between C/C composites with and without WC filaments on both macroscopic and microscopic ablation morphologies and the ablation rates of the former are higher than the latter. It is found that the ablation process of C/C composites with WC filaments includes oxidation of carbon fibers, carbon matrices and WC, melting of WC and WO 3, and denudation of WC, WO 3 and C/C composites. Oxidation and melting of WC leads to the formation of holes in z directional carbon fiber bundles, which increases the coarseness of the ablation surfaces of the composites, speeds up ablation and leads to the higher ablation rate. Moreover, it is further found that the molten WC and WO 3 cannot form a continuous film on the ablation surface to prevent further ablation of C/C composites.
NASA Astrophysics Data System (ADS)
Xu, Feng; Ma, Zhuang; Li, Hezhang; Gao, Lihong; Wang, Fuchi
2017-05-01
Benzoxazine resin with good heat resistance, low combustion heat release and high char yield is a promising thermosetting resin. Meanwhile, research shows that the inorganic filler can effectively improve the thermodynamic property of the resin. It makes that the inorganic filler modified benzoxazine may have a potential application in laser ablation. The benzoxazine coating with and without inorganic filler ammonium polyphosphate, melamine and pentaerythritol (P-BOZ and BOZ) were prepared by brush and thermal curing method. The ablation properties of these coatings irradiated by high-intensity laser were investigated. The scanning electron microscope, Raman spectroscopy and thermal gravimetric analysis were used to characterize the micrographs, carbon layer structure and thermodynamic property of the sample. Results show that the composite coating has excellent thermal protective properties. The back temperature of 20 wt% P-BOZ coating under different parameter laser power (1000W/cm2, 5s; 1000W/cm2, 10s) are 40% lower than these of the BOZ coating and the 20 wt% P-BOZ has higher mass ablation rate. In the surface layer of the irradiated area, dense carbon layer is produced which reduces the absorb of the laser energy of the interior. In the interior of the sample, a large number of closed bell shaped holes are generated which are beneficial to obstruct the heat conduction.
NASA Astrophysics Data System (ADS)
Brigitte Neuland, Maike; Riedo, Andreas; Meyer, Stefan; Mezger, Klaus; Tulej, Marek; Wurz, Peter
2013-04-01
The knowledge of the chemical composition of moons, comets, asteroids or other planetary bodies is of particular importance for the investigation of the origin and evolution of the Solar System. For cosmochemistry, the elemental and isotopic composition of the surface material is essential information to investigate origin, differentiation and evolution processes of the body and therefore the history of our Solar System [1]. We show that the use of laser-based mass spectrometers is essential in such research because of their high sensitivity in the ppm range and their capability for quantitative elemental and isotopic analysis. A miniaturised Laser Ablation Time-of-Flight Mass Spectrometer (LMS) was developed in our group to study the elemental composition of solid samples [2]. The instrument's small size and light weight make it suitable for an application on a space mission to determine the elemental composition of a planetary surface for example [3]. Meteorites offer the excellent possibility to study extraterrestrial material in the laboratory. To demonstrate the sensitivity and functionality of the LMS instrument, a sample of the Allende meteorite has been investigated with a high spatial resolution. The LMS measurements allowed investigations of the elemental abundances in the Allende meteorite and detailed studies of the mineralogy and volatility [4]. These approaches can be of considerable interest for in situ investigation of grains and inhomogeneous materials with high sensitivity on a planetary surface. [1] Wurz, P., Whitby, J., Managadze, G., 2009, Laser Mass Spectrometry in Planetary Science, AIP Conf. Proc. CP1144, 70-75. [2] Tulej, M., Riedo, A., Iakovleva, M., Wurz, P., 2012, Int. J. Spec., On Applicability of a Miniaturized Laser Ablation Time of Flight Mass Spectrometer for Trace Element Measurements, article ID 234949. [3] Riedo, A., Bieler, A., Neuland, M., Tulej, M., Wurz, P., 2012, Performance evaluation of a miniature laser ablation time-of-flight mass spectrometer designed for in-situ investigations in planetary space research, J. Mass Spectrom., in press. [4] Neuland, M.B., Meyer, S., Mezger, K., Riedo, A., Tulej, M., Wurz, P., Probing the Allende meteorite with a miniature Laser-Ablation Mass Analyser for space application, Planetary and Space Science, Special Issue: Terrestrial Planets II, submitted
NASA Astrophysics Data System (ADS)
Yoon, Soon-Gil; Lee, Jai-Chan; Safari, A.
1994-09-01
The chemical composition and electrical properties were investigated for epitaxially crystallized (Ba(0.5),Sr(0.5))TiO3 (BST) films deposited on Pt/MgO and YBa2Cu3O(7-x) (YBCO)/MgO substrates by the laser ablation technique. Rutherford backscattering spectroscopy analysis shows that thin films on Pt/MgO have almost the same stoichiometric composition as the target material. Films deposited at 600 C exhibited an excellent epitaxial growth, a dielectric constant of 430, and a dissipation factor of 0.02 at 10 kHz frequency. They have a charge storage density of 40 fC/sq micron at an applied electric field of 0.15 MV/cm. Leakage current density of BST thin films on Pt/MgO was smaller than on YBCO/MgO. Their leakage current density is about 0.8 microA/sq cm at an applied electric field of 0.15 MV/cm.
Sun, Yang; Zheng, Yuanyi; Ran, Haitao; Zhou, Yang; Shen, Hongxia; Chen, Yu; Chen, Hangrong; Krupka, Tianyi M; Li, Ao; Li, Pan; Wang, Zhibiao; Wang, Zhigang
2012-08-01
Organic/inorganic, hybrid, multifunctional, material-based platforms combine the merits of diverse functionalities of inorganic nanoparticles and the excellent biocompatibility of organic systems. In this work, superparamagnetic poly(lactic-co-glycolic acid) (PLGA) microcapsules (Fe(3)O(4)/PLGA) have been developed, as a proof-of-concept, for the application in ultrasound/magnetic resonance dual-modality biological imaging and enhancing the therapeutic efficiency of high intensity focused ultrasound (HIFU) breast cancer surgery in vitro and in vivo. Hydrophobic Fe(3)O(4) nanoparticles were successfully integrated into PLGA microcapsules by a typical double emulsion evaporation process. In this process, highly dispersed superparamagnetic Fe(3)O(4)/PLGA composite microcapsules with well-defined spherical morphology were obtained with an average diameter of 885.6 nm. The potential of these microcapsules as dual contrast agents for ultrasonography and magnetic resonance imaging were demonstrated in vitro and, also, preliminarily in vivo. Meanwhile, the prepared superparamagnetic composite microcapsules were administrated into rabbits bearing breast cancer model for the evaluation of the in vivo HIFU synergistic ablation efficiency caused by the introduction of such microcapsules. Our results showed that the employment of the composite microcapsules could efficiently enhance ultrasound imaging of cancer, and greatly enhance the HIFU ablation of breast cancer in rabbits. In addition, pathological examination was systematically performed to detect the structural changes of the target tissue caused by HIFU ablation. This finding demonstrated that successful introduction of these superparamagnetic microcapsules into HIFU cancer surgery provided an alternative strategy for the highly efficient imaging-guided non-invasive HIFU synergistic therapy of cancer. Copyright © 2012 Elsevier Ltd. All rights reserved.
Numerical Simulation of Thermal Response and Ablation Behavior of a Hybrid Carbon/Carbon Composite
NASA Astrophysics Data System (ADS)
Zhang, Bai; Li, Xudong
2017-09-01
The thermal response and ablation behavior of a hybrid carbon/carbon (C/C) composite are studied herein by using a numerical model. This model is based on the energy- and mass-conservation principles as well as on the calculation of the thermophysical properties of materials. The thermal response and ablation behavior are simulated from the perspective of the matrix and fiber components of a hybrid C/C composite. The thermophysical properties during ablation are calculated, and a moving boundary is implemented to consider the recession of the ablation surface. The temperature distribution, thermophysical properties, char layer thickness, linear ablation rate, mass flow rate of the pyrolysis gases, and mass loss of the hybrid C/C composite are quantitatively predicted. This numerical study describing the thermal response and ablation behavior provides a fundamental understanding of the ablative mechanism of a hybrid C/C composite, serving as a reference and basis for further designs and optimizations of thermoprotective materials.
Numerical Simulation of Thermal Response and Ablation Behavior of a Hybrid Carbon/Carbon Composite
NASA Astrophysics Data System (ADS)
Zhang, Bai; Li, Xudong
2018-06-01
The thermal response and ablation behavior of a hybrid carbon/carbon (C/C) composite are studied herein by using a numerical model. This model is based on the energy- and mass-conservation principles as well as on the calculation of the thermophysical properties of materials. The thermal response and ablation behavior are simulated from the perspective of the matrix and fiber components of a hybrid C/C composite. The thermophysical properties during ablation are calculated, and a moving boundary is implemented to consider the recession of the ablation surface. The temperature distribution, thermophysical properties, char layer thickness, linear ablation rate, mass flow rate of the pyrolysis gases, and mass loss of the hybrid C/C composite are quantitatively predicted. This numerical study describing the thermal response and ablation behavior provides a fundamental understanding of the ablative mechanism of a hybrid C/C composite, serving as a reference and basis for further designs and optimizations of thermoprotective materials.
Trowelable ablative coating composition and method of use
NASA Technical Reports Server (NTRS)
Headrick, Stephen E. (Inventor); Hill, Roger L. (Inventor)
1989-01-01
A trowelable ablative coating composition is disclosed. The composition comprises an epoxy resin, an amide curing agent, glass microspheres and ground cork. A method for protecting a substrate is also disclosed. The method comprises applying the trowelable ablative coating discussed above to a substrate and curing the coating composition.
Trowelable ablative coating composition and method of use
NASA Technical Reports Server (NTRS)
Headrick, Stephen E. (Inventor); Hill, Roger L. (Inventor)
1988-01-01
A trowelable ablative coating composition is disclosed. The composition comprises an epoxy resin, an amide curing agent, glass microspheres and ground cork. A method for protecting a substrate is also disclosed. The method comprises applying the trowelable ablative coating discussed above to a substrate and curing the coating composition.
NASA Astrophysics Data System (ADS)
Yin, J. J.; Chang, F.; Li, S. L.; Yao, X. L.; Sun, J. R.; Xiao, Y.
2017-10-01
According to the mathematical analysis model constructed on the basis of energy-balance relationship in lightning strike, and accompany with the simplified calculation strategy of composite resin pyrolysis degree dependent electrical conductivity, an effective three dimensional thermal-electrical coupling analysis finite element model of composite laminate suffered from lightning current was established based on ABAQUS, to elucidate the effects of lighting current waveform parameters and thermal/electrical properties of composite laminate on the extent of ablation damage. Simulated predictions agree well with the composite lightning strike directed effect experimental data, illustrating the potential accuracy of the constructed model. The analytical results revealed that extent of composite lightning strike ablation damage can be characterized by action integral validly, there exist remarkable power function relationships between action integral and visual damage area, projected damage area, maximum damage depth and damage volume of ablation damage, and enhancing the electrical conductivity and specific heat of composite, ablation damage will be descended obviously, power function relationships also exist between electrical conductivity, specific heat and ablation damage, however, the impact of thermal conductivity on the extent of ablation damage is not notable. The conclusions obtained provide some guidance for composite anti-lightning strike structure-function integration design.
Thermal response of a 4D carbon/carbon composite with volume ablation: a numerical simulation study
NASA Astrophysics Data System (ADS)
Zhang, Bai; Li, Xudong
2018-02-01
As carbon/carbon composites usually work at high temperature environments, material ablation inevitably occurs, which further affects the system stability and safety. In this paper, the thermal response of a thermoprotective four-directional carbon/carbon (4D C/C) composite is studied herein using a numerical model focusing on volume ablation. The model is based on energy- and mass-conservation principles as well as on the thermal decomposition equation of solid materials. The thermophysical properties of the C/C composite during the ablation process are calculated, and the thermal response during ablation, including temperature distribution, density, decomposition rate, char layer thickness, and mass loss, are quantitatively predicted. The present numerical study provides a fundamental understanding of the ablative mechanisms of a 4D C/C composite, serving as a reference and basis for further designs and optimizations of thermoprotective materials.
Interaction of gases with ablative composites. II - Water
NASA Technical Reports Server (NTRS)
Honeycutt, R. H., III; Wightman, J. P.
1974-01-01
An investigation was conducted to study the sorption of water on two ablative composites and their components as a function of pressure and temperature. A pressure range from 0.001 to 10 torr and a temperature range from 25 to 35 C were considered in the investigation. It was found that the sorption of water vapor by the ablative composites and their components varied directly with pressure. The components of the ablative composites included phenolic spheres, cork, a carbon-glass fiber mixture, glass spheres, silica fibers, and a silicone elastomer.
Reflectivity and laser ablation of ZrB2/Cu ultra high temperature ceramic
NASA Astrophysics Data System (ADS)
Yan, Zhenyu; Ma, Zhuang; Zhu, Shizhen; Liu, Ling; Xu, Qiang
2013-05-01
Ultra high temperature ceramics (UHTCs) were thought to be candidates for laser protective materials due to their high melting point, thermal shock and ablation resistance. The ablation behaviors of UHTCs like ZrB2 and its composite had been intensely investigated by the means of arc, plasma, oxyacetylene ablation. However, the ablation behavior under laser irradiation was still unknown by now. In this paper, the dense bulk composites of ZrB2/Cu were successfully sintered by spark plasma sintering (SPS) at 1650 degree C for 3min. The reflectivity of the composites measured by spectrophotometry achieved 60% in near infrared range and it decreased with the increasing wavelength of incident light. High intensity laser ablation was carried out on the ZrB2/Cu surface. The phase composition and microstructure changes before and after laser irradiation were characterized by X-ray diffraction and SEM respectively. The results revealed that the oxidation and melting were the main mechanisms during the ablation processing.
Low temperature ablation models made by pressure/vacuum application
NASA Technical Reports Server (NTRS)
Fischer, M. C.; Heier, W. C.
1970-01-01
Method developed employs high pressure combined with strong vacuum force to compact ablation models into desired conical shape. Technique eliminates vapor hazard and results in high material density providing excellent structural integrity.
PHOTONICS AND NANOTECHNOLOGY Laser synthesis and modification of composite nanoparticles in liquids
NASA Astrophysics Data System (ADS)
Tarasenko, N. V.; Butsen, A. V.
2010-12-01
The works devoted to the formation and modification of nanoparticles using laser ablation of solid targets in liquids are reviewed. Several approaches to implement laser ablation in liquids, aimed at synthesising nanoparticles of complex composition, are considered: direct laser ablation of a target of corresponding composition, laser ablation of a combined target composed of two different metals, laser irradiation of a mixture of two or more colloidal solutions, and laser ablation in reactive liquids. The properties of two-component bimetallic systems (Ag — Cu, Ag — Au), semiconductor nanocrystals (ZnO, CdSe), chalcopyrite nanoparticles, and doped oxide nanoparticles (ZnO:Ag, Gd2O2:Tb3+) formed as a result of single- and double-pulse laser ablation in different liquids (water, ethanol, acetone, solutions of polysaccharides) are discussed.
Highly flexible, nonflammable and free-standing SiC nanowire paper
NASA Astrophysics Data System (ADS)
Chen, Jianjun; Liao, Xin; Wang, Mingming; Liu, Zhaoxiang; Zhang, Judong; Ding, Lijuan; Gao, Li; Li, Ye
2015-03-01
Flexible paper-like semiconductor nanowire materials are expected to meet the criteria for some emerging applications, such as components of flexible solar cells, electrical batteries, supercapacitors, nanocomposites, bendable or wearable electronic or optoelectronic components, and so on. As a new generation of wide-bandgap semiconductors and reinforcements in composites, SiC nanowires have advantages in power electronic applications and nanofiber reinforced ceramic composites. Herein, free-standing SiC nanowire paper consisting of ultralong single-crystalline SiC nanowires was prepared through a facile vacuum filtration approach. The ultralong SiC nanowires were synthesized by a sol-gel and carbothermal reduction method. The flexible paper composed of SiC nanowires is ~100 nm in width and up to several hundreds of micrometers in length. The nanowires are intertwisted with each other to form a three-dimensional network-like structure. SiC nanowire paper exhibits high flexibility and strong mechanical stability. The refractory performance and thermal stability of SiC nanowire paper were also investigated. The paper not only exhibits excellent nonflammability in fire, but also remains well preserved without visible damage when it is heated in an electric oven at a high temperature (1000 °C) for 3 h. With its high flexibility, excellent nonflammability, and high thermal stability, the free-standing SiC nanowire paper may have the potential to improve the ablation resistance of high temperature ceramic composites.Flexible paper-like semiconductor nanowire materials are expected to meet the criteria for some emerging applications, such as components of flexible solar cells, electrical batteries, supercapacitors, nanocomposites, bendable or wearable electronic or optoelectronic components, and so on. As a new generation of wide-bandgap semiconductors and reinforcements in composites, SiC nanowires have advantages in power electronic applications and nanofiber reinforced ceramic composites. Herein, free-standing SiC nanowire paper consisting of ultralong single-crystalline SiC nanowires was prepared through a facile vacuum filtration approach. The ultralong SiC nanowires were synthesized by a sol-gel and carbothermal reduction method. The flexible paper composed of SiC nanowires is ~100 nm in width and up to several hundreds of micrometers in length. The nanowires are intertwisted with each other to form a three-dimensional network-like structure. SiC nanowire paper exhibits high flexibility and strong mechanical stability. The refractory performance and thermal stability of SiC nanowire paper were also investigated. The paper not only exhibits excellent nonflammability in fire, but also remains well preserved without visible damage when it is heated in an electric oven at a high temperature (1000 °C) for 3 h. With its high flexibility, excellent nonflammability, and high thermal stability, the free-standing SiC nanowire paper may have the potential to improve the ablation resistance of high temperature ceramic composites. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr00776c
Ablation behaviors of carbon reinforced polymer composites by laser of different operation modes
NASA Astrophysics Data System (ADS)
Wu, Chen-Wu; Wu, Xian-Qian; Huang, Chen-Guang
2015-10-01
Laser ablation mechanism of Carbon Fiber Reinforced Polymer (CFRP) composite is of critical meaning for the laser machining process. The ablation behaviors are investigated on the CFRP laminates subject to continuous wave, long duration pulsed wave and short duration pulsed wave lasers. Distinctive ablation phenomena have been observed and the effects of laser operation modes are discussed. The typical temperature patterns resulted from laser irradiation are computed by finite element analysis and thereby the different ablation mechanisms are interpreted.
NASA Technical Reports Server (NTRS)
Hall, William B.
1988-01-01
Carbon-phenolic composite materials are used in the ablation process in the nozzles of the Space Shuttle Main Engine. The nozzle is lined with carbon cloth-phenolic resin composites. The extreme heat and erosion of the burning propellant are controlled by the carbon-phenolic composite by means of ablation, a heat and mass transfer process in which a large amount of heat is dissipated by sacrificailly removing material from a surface. Phenolic materials ablate with the initial formation of a char. The depth of the char is a function of the heat conduction coefficient of the composite. The char layer is a poor conductor so it protects the underlying phenolic composite from the high heat of the burning propellant. The nozzle component ablative liners (carbon cloth-phenolic resin composites) are tape wrapped, hydroclave and/or autoclave cured, machined and assembled. The tape consists of prepreg broadcloth. The materials flow sheet for the nozzle ablative liners is given. The prepreg is a three component system: phenolic resin, carbon cloth, and carbon filler. This is Volume 2 of the report, Test Methods and Specifications.
NASA Technical Reports Server (NTRS)
Pike, R. W.; Delvalle, E. G.
1974-01-01
The decomposition of ablative composites is described along with the transport phenomena of pyrolysis gases which result from the decomposition of these plastics as they flow through the porous char of char-forming ablators. The pyrolysis products are those formed by the thermal degradation of nylon-phenolic resin and silicone elastomer composites. Emphasis is placed on the nature and extent of chemical reactions of the pyrolysis products and the char, along with the energy absorbed by the combined pyrolysis and char zone. Chemical reactions with thermodynamically consistent kinetic data are determined in order to develop a realistic analysis for predicting the thermal performance of ablative heat shields.
Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation of liver tumours.
Wijlemans, J W; Bartels, L W; Deckers, R; Ries, M; Mali, W P Th M; Moonen, C T W; van den Bosch, M A A J
2012-09-28
Recent decades have seen a paradigm shift in the treatment of liver tumours from invasive surgical procedures to minimally invasive image-guided ablation techniques. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a novel, completely non-invasive ablation technique that has the potential to change the field of liver tumour ablation. The image guidance, using MR imaging and MR temperature mapping, provides excellent planning images and real-time temperature information during the ablation procedure. However, before clinical implementation of MR-HIFU for liver tumour ablation is feasible, several organ-specific challenges have to be addressed. In this review we discuss the MR-HIFU ablation technique, the liver-specific challenges for MR-HIFU tumour ablation, and the proposed solutions for clinical translation.
Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation of liver tumours
Bartels, L.W.; Deckers, R.; Ries, M.; Mali, W.P.Th.M.; Moonen, C.T.W.; van den Bosch, M.A.A.J.
2012-01-01
Abstract Recent decades have seen a paradigm shift in the treatment of liver tumours from invasive surgical procedures to minimally invasive image-guided ablation techniques. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a novel, completely non-invasive ablation technique that has the potential to change the field of liver tumour ablation. The image guidance, using MR imaging and MR temperature mapping, provides excellent planning images and real-time temperature information during the ablation procedure. However, before clinical implementation of MR-HIFU for liver tumour ablation is feasible, several organ-specific challenges have to be addressed. In this review we discuss the MR-HIFU ablation technique, the liver-specific challenges for MR-HIFU tumour ablation, and the proposed solutions for clinical translation. PMID:23022541
Composition analysis by scanning femtosecond laser ultraprobing (CASFLU).
Ishikawa, Muriel Y.; Wood, Lowell L.; Campbell, E. Michael; Stuart, Brent C.; Perry, Michael D.
2002-01-01
The composition analysis by scanning femtosecond ultraprobing (CASFLU) technology scans a focused train of extremely short-duration, very intense laser pulses across a sample. The partially-ionized plasma ablated by each pulse is spectrometrically analyzed in real time, determining the ablated material's composition. The steering of the scanned beam thus is computer directed to either continue ablative material-removal at the same site or to successively remove nearby material for the same type of composition analysis. This invention has utility in high-speed chemical-elemental, molecular-fragment and isotopic analyses of the microstructure composition of complex objects, e.g., the oxygen isotopic compositions of large populations of single osteons in bone.
NASA Astrophysics Data System (ADS)
Hui, Wei-Hua; Bao, Fu-Ting; Wei, Xiang-Geng; Liu, Yang
2015-12-01
In this paper, a new measuring method of ablation rate was proposed based on X-ray three-dimensional (3D) reconstruction. The ablation of 4-direction carbon/carbon composite nozzles was investigated in the combustion environment of a solid rocket motor, and the macroscopic ablation and linear recession rate were studied through the X-ray 3D reconstruction method. The results showed that the maximum relative error of the X-ray 3D reconstruction was 0.0576%, which met the minimum accuracy of the ablation analysis; along the nozzle axial direction, from convergence segment, throat to expansion segment, the ablation gradually weakened; in terms of defect ablation, the middle ablation was weak, while the ablation in both sides was more serious. In a word, the proposed reconstruction method based on X-ray about C/C nozzle ablation can construct a clear model of ablative nozzle which characterizes the details about micro-cracks, deposition, pores and surface to analyze ablation, so that this method can create the ablation curve in any surface clearly.
Polydopamine-Coated Magnetic Composite Particles with an Enhanced Photothermal Effect.
Zheng, Rui; Wang, Sheng; Tian, Ye; Jiang, Xinguo; Fu, Deliang; Shen, Shun; Yang, Wuli
2015-07-29
Recently, photothermal therapy (PTT) that utilizes photothermal conversion (PTC) agents to ablate cancer under near-infrared (NIR) irradiation has attracted a growing amount of attention because of its excellent therapeutic efficacy and improved target selectivity. Therefore, exploring novel PTC agents with an outstanding photothermal effect is a current research focus. Herein, we reported a polydopamine-coated magnetic composite particle with an enhanced PTC effect, which was synthesized simply through coating polydopamine (PDA) on the surface of magnetic Fe3O4 particles. Compared with magnetic Fe3O4 particles and PDA nanospheres, the core-shell nanomaterials exhibited an increased NIR absorption, and thus, an enhanced photothermal effect was obtained. We demonstrated the in vitro and in vivo effects of the photothermal therapy using our composite particles and their ability as a contrast agent in the T2-weighted magnetic resonance imaging. These results indicated that the multifunctional composite particles with enhanced photothermal effect are superior to magnetic Fe3O4 particles and PDA nanospheres alone.
Efficiency of planetesimal ablation in giant planetary envelopes
NASA Astrophysics Data System (ADS)
Pinhas, Arazi; Madhusudhan, Nikku; Clarke, Cathie
2016-12-01
Observations of exoplanetary spectra are leading to unprecedented constraints on their atmospheric elemental abundances, particularly O/H, C/H, and C/O ratios. Recent studies suggest that elemental ratios could provide important constraints on formation and migration mechanisms of giant exoplanets. A fundamental assumption in such studies is that the chemical composition of the planetary envelope represents the sum-total of compositions of the accreted gas and solids during the formation history of the planet. We investigate the efficiency with which accreted planetesimals ablate in a giant planetary envelope thereby contributing to its composition rather than sinking to the core. From considerations of aerodynamic drag causing `frictional ablation' and the envelope temperature structure causing `thermal ablation', we compute mass ablations for impacting planetesimals of radii 30 m to 1 km for different compositions (ice to iron) and a wide range of velocities and impact angles, assuming spherical symmetry. Icy impactors are fully ablated in the outer envelope for a wide range of parameters. Even for Fe impactors substantial ablation occurs in the envelope for a wide range of sizes and velocities. For example, iron impactors of sizes below ˜0.5 km and velocities above ˜30 km s-1 are found to ablate by ˜60-80 per cent within the outer envelope at pressures below 103 bar due to frictional ablation alone. For deeper pressures (˜107 bar), substantial ablation happens over a wider range of parameters. Therefore, our exploratory study suggests that atmospheric abundances of volatile elements in giant planets reflect their accretion history during formation.
Standardization of the carbon-phenolic materials and processes. Vol. 1: Experimental studies
NASA Technical Reports Server (NTRS)
Hall, William B.
1988-01-01
Carbon-phenolic composite materials are used as ablative material in the solid rocket motor nozzle of the Space Shuttle. The nozzle is lined with carbon cloth-phenolic resin composites. The nominal effects of the completely consumed solid propellant on the carbon-phenolic material are given. The extreme heat and erosion of the burning propellant are controlled by the carbon-phenolic composite by ablation, the heat and mass transfer process in which a large amount of heat is absorbed by sacrificially removing material from the nozzle surface. Phenolic materials ablate with the initial formation of a char. The depth of the char is a function of the heat conduction coefficient of the composite. The char layer is a very poor heat conductor so it protects the underlying phenolic composite from the high heat of the burning propellant. The nozzle component ablative liners (carbon cloth-phenolic composites) are tape wrapped, hydroclave and/or autoclave cured, machined, and assembled. The tape consists of a prepreg broadcloth. The materials flow sheet for the nozzle ablative liners is shown. The prepreg is a three component system: phenolic resin, carbon cloth, and carbon filler. This is Volume 1 of two, Experimental Studies.
Selective removal of esthetic composite restorations with spectral guided laser ablation
NASA Astrophysics Data System (ADS)
Yi, Ivana; Chan, Kenneth H.; Tsuji, Grant H.; Staninec, Michal; Darling, Cynthia L.; Fried, Daniel
2016-02-01
Dental composites are used for a wide range of applications such as fillings for cavities, adhesives for orthodontic brackets, and closure of gaps (diastemas) between teeth by esthetic bonding. Anterior restorations are used to replace missing, diseased and unsightly tooth structure for both appearance and function. When these restorations must be replaced, they are difficult to remove mechanically without causing excessive removal or damage to enamel because dental composites are color matched to teeth. Previous studies have shown that CO2 lasers have high ablation selectivity and are well suited for removal of composite on occlusal surfaces while minimizing healthy tissue loss. A spectral feedback guidance system may be used to discriminate between dental composite and dental hard tissue for selective ablation of composite material. The removal of composite restorations filling diastemas is more challenging due to the esthetic concern for anterior teeth. The objective of this study is to determine if composite spanning a diastema between anterior teeth can be removed by spectral guided laser ablation at clinically relevant rates with minimal damage to peripheral healthy tissue and with higher selectivity than a high speed dental handpiece.
NASA Astrophysics Data System (ADS)
Devulder, Veerle; Gerdes, Axel; Vanhaecke, Frank; Degryse, Patrick
2015-03-01
The applicability of laser ablation multi-collector inductively coupled plasma-mass spectrometry (LA-MC-ICP-MS) for the determination of the B isotopic composition in Roman glasses was investigated. The δ11B values thus obtained provide information on the natron flux used during the glass-making process. The glass samples used for this purpose were previously characterized using pneumatic nebulization (PN) MC-ICP-MS. Unfortunately, this method is time-consuming and labor-intensive and consumes some 100 mg of sample, which is a rather high amount for ancient materials. Therefore, the use of the less invasive and faster LA-MC-ICP-MS approach was explored. In this work, the results for 29 Roman glasses and 4 home-made glasses obtained using both techniques were compared to assess the suitability of LA-MC-ICP-MS in this context. The results are in excellent agreement within experimental uncertainty. No difference in overall mass discrimination was observed between the Roman glasses, NIST SRM 610 reference glass and B6 obsidian. The expanded uncertainty of the LA-MC-ICP-MS approach was estimated to be < 2‰, which is similar to that obtained upon sample digestion and PN-MC-ICP-MS measurement.
Radiofrequency ablation of hepatocellular carcinoma: pros and cons.
Rhim, Hyunchul; Lim, Hyo K
2010-09-01
Among locoregional treatments for hepatocellular carcinoma (HCC), radiofrequency ablation (RFA) has been accepted as the most popular alternative to curative transplantation or resection, and it shows an excellent local tumor control rate and acceptable morbidity. The benefits of RFA have been universally validated by the practice guidelines of international societies of hepatology. The main advantages of RFA include 1) it is minimally invasive with acceptable morbidity, 2) it enables excellent local tumor control, 3) it has promising long-term survival, and 4) it is a multimodal approach. Based on these pros, RFA will play an important role in managing the patient with early HCC (smaller than 3 cm with fewer than four tumors). The main limitations of current RFA technology in hepatic ablation include 1) limitation of ablation volume, 2) technically infeasible in some tumors due to conspicuity and dangerous location, and 3) the heat-sink effect. Many technical approaches have been introduced to overcome those limitations, including a novel guiding modality, use of artificial fluid or air, and combined treatment strategies. RFA will continue to play a role as a representative ablative modality in the management of HCC, even in the era of targeted agents.
Radiofrequency Ablation of Hepatocellular Carcinoma: Pros and Cons
Lim, Hyo K.
2010-01-01
Among locoregional treatments for hepatocellular carcinoma (HCC), radiofrequency ablation (RFA) has been accepted as the most popular alternative to curative transplantation or resection, and it shows an excellent local tumor control rate and acceptable morbidity. The benefits of RFA have been universally validated by the practice guidelines of international societies of hepatology. The main advantages of RFA include 1) it is minimally invasive with acceptable morbidity, 2) it enables excellent local tumor control, 3) it has promising long-term survival, and 4) it is a multimodal approach. Based on these pros, RFA will play an important role in managing the patient with early HCC (smaller than 3 cm with fewer than four tumors). The main limitations of current RFA technology in hepatic ablation include 1) limitation of ablation volume, 2) technically infeasible in some tumors due to conspicuity and dangerous location, and 3) the heat-sink effect. Many technical approaches have been introduced to overcome those limitations, including a novel guiding modality, use of artificial fluid or air, and combined treatment strategies. RFA will continue to play a role as a representative ablative modality in the management of HCC, even in the era of targeted agents. PMID:21103289
Davies, Huw Ob; Popplewell, Matthew; Darvall, Katy; Bate, Gareth; Bradbury, Andrew W
2016-05-01
The last 10 years have seen the introduction into everyday clinical practice of a wide range of novel non-surgical treatments for varicose veins. In July 2013, the UK National Institute for Health and Care Excellence recommended the following treatment hierarchy for varicose veins: endothermal ablation, ultrasound-guided foam sclerotherapy, surgery and compression hosiery. The aim of this paper is to review the randomised controlled trials that have compared endothermal ablation and ultrasound-guided foam sclerotherapy to determine if the level 1 evidence base still supports an "endothermal ablation first" strategy for the treatment of varicose veins. A PubMed and OVID literature search (until 31 January 2015) was performed and randomised controlled trials comparing endothermal ablation and ultrasound-guided foam sclerotherapy were obtained. Although anatomical success appeared higher with endothermal ablation than ultrasound-guided foam sclerotherapy, clinical success and patient-reported outcomes measures were similar. Morbidity and complication rates were very low and not significantly different between endothermal ablation and ultrasound-guided foam sclerotherapy. Ultrasound-guided foam sclerotherapy was consistently less expensive that endothermal ablation. All endovenous modalities appear to be successful and have a role in modern day practice. Although further work is required to optimise ultrasound-guided foam sclerotherapy technique to maximise anatomical success and minimise retreatment, the present level 1 evidence base shows there is no significant difference in clinical important outcomes between ultrasound-guided foam sclerotherapy and endothermal ablation. As ultrasound-guided foam sclerotherapy is less expensive, it is likely to be a more cost-effective option in most patients in most healthcare settings. Strict adherence to the treatment hierarchy recommended by National Institute for Health and Care Excellence seems unjustified. © The Author(s) 2015.
Ablation Resistant Zirconium and Hafnium Ceramics
NASA Technical Reports Server (NTRS)
Bull, Jeffrey (Inventor); White, Michael J. (Inventor); Kaufman, Larry (Inventor)
1998-01-01
High temperature ablation resistant ceramic composites have been made. These ceramics are composites of zirconium diboride and zirconium carbide with silicon carbide, hafnium diboride and hafnium carbide with silicon carbide and ceramic composites which contain mixed diborides and/or carbides of zirconium and hafnium. along with silicon carbide.
Effects of material composition on the ablation performance of low density elastomeric ablators
NASA Technical Reports Server (NTRS)
Tompkins, S. S.; Kabana, W. P.
1973-01-01
The ablation performance of materials composed of various concentrations of nylon, hollow silica spheres, hollow phenolic spheres, and four elastomeric resins was determined. Both blunt-body and flat-panel specimens were used, the cold-wall heating-rate ranges being 0.11 to 0.8 MW/sq m, respectively. The corresponding surface pressure ranges for these tests were 0.017 to 0.037 atmosphere and 0.004 to 0.005 atmosphere. Some of the results show that (1) the addition of nylon significantly improved the ablation performance, but the nylon was not compatible with one resin system; (2) panel and blunt-body specimen data do not show the same effect of phenolic sphere content on ablation effectiveness; and (3) there appears to be an optimum concentration of hollow silica spheres for good ablation performance. The composition of an efficient, nonproprietary ablator for lifting body application is identified and the ablation performance of this ablator is compared with the performance of three commercially available materials.
Controlled Contamination of Epoxy Composites with PDMS and Removal by Laser Ablation
NASA Technical Reports Server (NTRS)
Palmieri, Frank; Ledesma, Rodolfo; Cataldo, Daniel; Lin, Yi; Wohl, Christopher; Gupta, Mool; Connell, John
2016-01-01
Surface preparation is critical to the performance of adhesively bonded composites. During manufacturing, minute quantities of mold release compounds are inevitably deposited on faying surfaces and may compromise bond performance. To ensure safety, mechanical fasteners and other crack arrest features must be installed in the bondlines of primary structures, which negates some advantages of adhesively bonded construction. Laser ablation is an automated, repeatable, and scalable process with high potential for the surface preparation of metals and composites in critical applications such as primary airframe structures. In this study, laser ablation is evaluated on composite surfaces for the removal of polydimethylsiloxane (PDMS), a common mold release material. Composite panels were contaminated uniformly with PDMS film thicknesses as low as 6.0 nm as measured by variable angle spectroscopic ellipsometry. Bond performance was assessed by mechanical testing using a 250 F cure, epoxy adhesive and compared with pre-bond surface inspection results. Water contact angle, optically stimulated electron emission, and laser induced breakdown spectroscopy were used to characterize contaminated and laser ablated surfaces. The failure mode obtained from double cantilever beam tests correlated well with surface characterization data. The test results indicated that even low levels of PDMS were not completely removed by laser ablation.
Constraints on Meteoric Smoke Composition and Meteoric Influx Using SOFIE Observations With Models
NASA Astrophysics Data System (ADS)
Hervig, Mark E.; Brooke, James S. A.; Feng, Wuhu; Bardeen, Charles G.; Plane, John M. C.
2017-12-01
The composition of meteoric smoke particles in the mesosphere is constrained using measurements from the Solar Occultation For Ice Experiment (SOFIE) in conjunction with models. Comparing the multiwavelength observations with models suggests smoke compositions of magnetite, wüstite, magnesiowüstite, or iron-rich olivine. Smoke compositions of pure pyroxene, hematite, iron-poor olivine, magnesium silicate, and silica are excluded, although this may be because these materials have weak signatures at the SOFIE wavelengths. Information concerning smoke composition allows the SOFIE extinction measurements to be converted to smoke volume density. Comparing the observed volume density with model results for varying meteoric influx (MI) provides constraints on the ablated fraction of incoming meteoric material. The results indicate a global ablated MI of 3.3 ± 1.9 t d-1, which represents only iron, magnesium, and possibly silica, given the smoke compositions indicated here. Considering the optics and iron content of individual smoke compositions gives an ablated Fe influx of 1.8 ± 0.9 t d-1. Finally, the global total meteoric influx (ablated plus surviving) is estimated to be 30 ± 18 t d-1, when considering the present results and a recent description of the speciation of meteoric material.
Glue, steam and Clarivein--Best practice techniques and evidence.
Whiteley, Mark S
2015-11-01
In July 2013, the National Institute of Health and Clinical Excellence (NICE) recommended "endothermal" ablation (meaning endovenous thermal ablation) is the first line treatment for truncal venous reflux in varicose veins. The initial endovenous thermoablation devices were radiofrequency ablation and endovenous laser ablation. More recently, Glue (cyanoacrylate), endovenous steam and Clarivein (mechanochemical ablation or MOCA) have entered the market as new endovenous techniques for the treatment of varicose veins. Glue and Clarivein do not require tumescent anaesthesia and do not use heat and therefore termed non-tumescent non-thermal (NTNT). Steam both requires tumescence and is also a thermal technique (TT). This article reviews the current position of these 3 new technologies in the treatment of varicose veins. © The Author(s) 2015.
SwiftLase: a new technology for char-free ablation in rectal surgery
NASA Astrophysics Data System (ADS)
Arnold, David A.
1995-05-01
We describe layer-by-layer char-free ablation of hemorrhoids and other rectal lesions at very low CO2 laser power levels with a miniature `SwiftLaser' optomechanical flashscanner. Increased speed with excellent control, very shallow thermal damage, and less postoperative pain are the main advantages of the flashscan technology in rectal surgery.
Yue-Chun, Li; Jia-Feng, Lin; Jia-Xuan, Lin
2015-10-01
Electrocardiographic characteristics can be useful in differentiating between right ventricular outflow tract (RVOT) and aortic sinus cusp (ASC) ventricular arrhythmias. Ventricular arrhythmias originating from ASC, however, show preferential conduction to RVOT that may render the algorithms of electrocardiographic characteristics less reliable. Even though there are few reports describing ventricular arrhythmias with ASC origins and endocardial breakout sites of RVOT, progressive dynamic changes in QRS morphology of the ventricular arrhythmias during ablation obtained were rare.This case report describes a patient with symptomatic premature ventricular contractions of left ASC origin presenting an electrocardiogram (ECG) characteristic of right ventricular outflow tract before ablation. Pacing at right ventricular outflow tract reproduced an excellent pace map. When radiofrequency catheter ablation was applied to the right ventricular outflow tract, the QRS morphology of premature ventricular contractions progressively changed from ECG characteristics of right ventricular outflow tract origin to ECG characteristics of left ASC origin.Successful radiofrequency catheter ablation was achieved at the site of the earliest ventricular activation in the left ASC. The distance between the successful ablation site of the left ASC and the site with an excellent pace map of the RVOT was 20 mm.The ndings could be strong evidence for a preferential conduction via the myocardial bers from the ASC origin to the breakout site in the right ventricular outflow tract. This case demonstrates that ventricular arrhythmias with a single origin and exit shift may exhibit QRS morphology changes.
NASA Astrophysics Data System (ADS)
Ma, Yan; Chen, Zhaohui
2013-09-01
A way to improve the ablation properties of the C/SiC composites in an oxyacetylene torch environment was investigated by the precursor infiltration and pyrolysis route using three organic precursors (zirconium butoxide, polycarbosilane, and divinylbenzene). The ceramic matrix derived from the precursors at 1200 °C was mainly a mixture of SiC, ZrO2, and C. After annealing at 1600 °C for 1 h, ZrO2 partly transformed to ZrC because of the carbothermic reductions and completely transformed to ZrC at 1800 °C in 1 h. The mechanical properties of the composites decreased with increasing temperature, while the ablation resistance increased due to the increasing content of ZrC. Compared with C/SiC composites, the ablation resistance of the C/Zr-O-Si-C composites overwhelms because of the oxide films which formed on the ablation surfaces. And, the films were composed of two layers: the porous surface layer (the mixture of ZrO2 and SiO2) and the dense underlayer (SiO2).
NASA Astrophysics Data System (ADS)
Bulgakov, A. V.; Evtushenko, A. B.; Shukhov, Yu G.; Ozerov, I.; Marin, W.
2010-12-01
Formation of small clusters during pulsed ablation of two binary semiconductors, zinc oxide and indium phosphide, in vacuum by UV, visible, and IR laser radiation is comparatively studied. The irradiation conditions favourable for generation of neutral and charged ZnnOm and InnPm clusters of different stoichiometry in the ablation products are found. The size and composition of the clusters, their expansion dynamics and reactivity are analysed by time-of-flight mass spectrometry. A particular attention is paid to the mechanisms of ZnO and InP ablation as a function of laser fluence, with the use of different ablation models. It is established that ZnO evapourates congruently in a wide range of irradiation conditions, while InP ablation leads to enrichment of the target surface with indium. It is shown that this radically different character of semiconductor ablation determines the composition of the nanostructures formed: zinc oxide clusters are mainly stoichiometric, whereas InnPm particles are significantly enriched with indium.
Composite Configuration Interventional Therapy Robot for the Microwave Ablation of Liver Tumors
NASA Astrophysics Data System (ADS)
Cao, Ying-Yu; Xue, Long; Qi, Bo-Jin; Jiang, Li-Pei; Deng, Shuang-Cheng; Liang, Ping; Liu, Jia
2017-11-01
The existing interventional therapy robots for the microwave ablation of liver tumors have a poor clinical applicability with a large volume, low positioning speed and complex automatic navigation control. To solve above problems, a composite configuration interventional therapy robot with passive and active joints is developed. The design of composite configuration reduces the size of the robot under the premise of a wide range of movement, and the robot with composite configuration can realizes rapid positioning with operation safety. The cumulative error of positioning is eliminated and the control complexity is reduced by decoupling active parts. The navigation algorithms for the robot are proposed based on solution of the inverse kinematics and geometric analysis. A simulation clinical test method is designed for the robot, and the functions of the robot and the navigation algorithms are verified by the test method. The mean error of navigation is 1.488 mm and the maximum error is 2.056 mm, and the positioning time for the ablation needle is in 10 s. The experimental results show that the designed robot can meet the clinical requirements for the microwave ablation of liver tumors. The composite configuration is proposed in development of the interventional therapy robot for the microwave ablation of liver tumors, which provides a new idea for the structural design of medical robots.
NASA Astrophysics Data System (ADS)
Sheikh Mohamed, M.; Poulose, Aby Cheruvathoor; Veeranarayanan, Srivani; Romero Aburto, Rebecca; Mitcham, Trevor; Suzuki, Yuko; Sakamoto, Yasushi; Ajayan, Pulickel M.; Bouchard, Richard R.; Yoshida, Yasuhiko; Maekawa, Toru; Sakthi Kumar, D.
2016-04-01
A simple, crude Jatropha curcas (JC) oil-based synthesis approach, devoid of any toxic phosphine and pyrophoric ligands, to produce size and shape tuned CdSe QDs and a further copper sulfide (Cu2S) encasing is presented. The QDs exhibited excellent photoluminescent properties with narrow band gap emission. Furthermore, the Cu2S shell rendered additional cytocompatibility and stability to the hybrid nanomaterial, which are major factors for translational and clinical applications of QDs. The nanocomposites were PEGylated and folate conjugated to augment their cytoamiability and enhance their specificity towards cancer cells. The nanohybrids possess potentials for visible, near infrared (NIR), photoacoustic (PA) and computed tomography (μCT) imaging. The diverse functionality of the composite was derived from the multi-channel imaging abilities and thermal competence on NIR laser irradiation to specifically actuate the photo-thermal ablation of brain cancer cells.A simple, crude Jatropha curcas (JC) oil-based synthesis approach, devoid of any toxic phosphine and pyrophoric ligands, to produce size and shape tuned CdSe QDs and a further copper sulfide (Cu2S) encasing is presented. The QDs exhibited excellent photoluminescent properties with narrow band gap emission. Furthermore, the Cu2S shell rendered additional cytocompatibility and stability to the hybrid nanomaterial, which are major factors for translational and clinical applications of QDs. The nanocomposites were PEGylated and folate conjugated to augment their cytoamiability and enhance their specificity towards cancer cells. The nanohybrids possess potentials for visible, near infrared (NIR), photoacoustic (PA) and computed tomography (μCT) imaging. The diverse functionality of the composite was derived from the multi-channel imaging abilities and thermal competence on NIR laser irradiation to specifically actuate the photo-thermal ablation of brain cancer cells. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr05225d
ABLATIVE COMPOSITES FOR LIFTING REENTRY THERMAL PROTECTION.
MECHANICAL PROPERTIES, THERMAL CONDUCTIVITY, ABLATION, DENSITY, TABLES(DATA), SPECIFIC HEAT, THERMOGRAVIMETRIC ANALYSIS, CORROSION RESISTANCE, COLORIMETRY , HEAT RESISTANT MATERIALS, ATMOSPHERE ENTRY.
Laser Surface Preparation of Epoxy Composites for Secondary Bonding: Optimization of Ablation Depth
NASA Technical Reports Server (NTRS)
Palmieri, Frank L.; Hopkins, John; Wohl, Christopher J.; Lin, Yi; Connell, John W.; Belcher, Marcus A.; Blohowiak, Kay Y.
2015-01-01
Surface preparation has been identified as one of the most critical aspects of attaining predictable and reliable adhesive bonds. Energetic processes such as laser ablation or plasma treatment are amenable to automation and are easily monitored and adjusted for controlled surface preparation. A laser ablation process was developed to accurately remove a targeted depth of resin, approximately 0.1 to 20 micrometers, from a carbon fiber reinforced epoxy composite surface while simultaneously changing surface chemistry and creating micro-roughness. This work demonstrates the application of this process to prepare composite surfaces for bonding without exposing or damaging fibers on the surface. Composite panels were prepared in an autoclave and had a resin layer approximately 10 micrometers thick above the fiber reinforcement. These composite panels were laser surface treated using several conditions, fabricated into bonded panels and hygrothermally aged. Bond performance of aged, experimental specimens was compared with grit blast surface treated specimens using a modified double cantilever beam test that enabled accelerated saturation of the specimen with water. Comparison of bonded specimens will be used to determine how ablation depth may affect average fracture energies and failure modes.
Kim, Tae Kyoung; Khalili, Korosh; Jang, Hyun-Jung
2015-01-01
A successful program for local ablation therapy for hepatocellular carcinoma (HCC) requires extensive imaging support for diagnosis and localization of HCC, imaging guidance for the ablation procedures, and post-treatment monitoring. Contrast-enhanced ultrasonography (CEUS) has several advantages over computed tomography/magnetic resonance imaging (CT/MRI), including real-time imaging capability, sensitive detection of arterial-phase hypervascularity and washout, no renal excretion, no ionizing radiation, repeatability, excellent patient compliance, and relatively low cost. CEUS is useful for image guidance for isoechoic lesions. While contrast-enhanced CT/MRI is the standard method for the diagnosis of HCC and post-ablation monitoring, CEUS is useful when CT/MRI findings are indeterminate or CT/MRI is contraindicated. This article provides a practical review of the role of CEUS in imaging algorithms for pre- and post-ablation therapy for HCC. PMID:26169081
NASA Astrophysics Data System (ADS)
Cheng, Joyce Y.; Fan, Kenneth; Fried, Daniel
2006-02-01
One perceived disadvantage of caries removal using lasers is the loss of the tactile feedback associated with the handpiece. However, alternative methods of acoustic and optical feedback become available with the laser that can be exploited to provide information about the chemical composition of the material ablated, the ablation efficiency and rate, the depth of the incision, and the surface and plume temperature during ablation. Such information can be used to increase the selectivity of ablation, avoid peripheral thermal damage and excessive heat deposition in the tooth, and provide a mechanism of robotic automation. The objective of this study was to test the hypothesis that a compact fiberoptic spectrometer could be used to differentiate between the ablation of sound and carious enamel and dentin and between dental hard tissues and composite. Sound and carious tooth surfaces along with composite restorative materials were scanned with λ=0.355, 2.79 and 9.3 μm laser pulses at irradiation intensities ranging from 0.5-100 J/cm2 and spectra were acquired from λ=250-900-nm using a compact fiber-optic spectrometer. Emission spectra varied markedly with the laser wavelength and pulse duration. Optical feedback was not successful in differentiating between sound and carious enamel and dentin even with the addition of various chromophores to carious lesion areas. However, the spectral feedback was successfully used to differentiate between composites and sound enamel and dentin enabling the selective removal of composite from tooth surfaces using a computer controlled λ=9.3-μm pulsed CO II laser and scanning system.
Picosecond Pulsed Laser Ablation for the Surface Preparation of Epoxy Composites
NASA Technical Reports Server (NTRS)
Palmieri, Frank; Ledesma, Rodolfo; Fulton, Tayler; Arthur, Alexandria; Eldridge, Keishara; Thibeault, Sheila; Lin, Yi; Wohl, Chris; Connell, John
2017-01-01
As part of a technical challenge under the Advanced Composites Program, methods for improving pre-bond process control for aerospace composite surface treatments and inspections, in conjunction with Federal Aviation Administration guidelines, are under investigation. The overall goal is to demonstrate high fidelity, rapid and reproducible surface treatment and surface characterization methods to reduce uncertainty associated with the bonding process. The desired outcomes are reliable bonded airframe structure, and reduced timeline to certification. In this work, laser ablation was conducted using a q-switched Nd:YVO4 laser capable of nominal pulse durations of 8 picoseconds (ps). Aerospace structural carbon fiber reinforced composites with an epoxy resin matrix were laser treated, characterized, processed into bonded assemblies and mechanically tested. The characterization of ablated surfaces were conducted using scanning electron microscopy (SEM), water contact angle (WCA) goniometry, micro laser induced breakdown spectroscopy (uLIBS), and electron spin resonance (ESR). The bond performance was assessed using a double cantilever beam (DCB) test with an epoxy adhesive. The surface characteristics and bond performance obtained from picosecond ablated carbon fiber reinforced plastics (CFRPs) are presented herein.
Vapor Grown Carbon Fiber/Phenolic Matrix Composites for Rocket Nozzles and Heat Shields
NASA Technical Reports Server (NTRS)
Patton, R. D.; Pittman, C. U., Jr.; Wang, L.; Day, A.; Hill, J. R.
2001-01-01
The ablation and mechanical and thermal properties of vapor grown carbon fiber (VGCF)/phenolic resin composites were evaluated to determine the potential of using this material in solid rocket motor nozzles. Composite specimens with varying VGCF loading (30%-50% wt) including one sample with ex-rayon carbon fiber plies were prepared and exposed to a plasma torch for 20 s with a heat flux of 16.5 MW/sq m at approximately 1650 C. Low erosion rates and little char formation were observed, confirming that these materials were promising for rocket motor nozzle materials. When fiber loadings increased, mechanical properties and ablative properties improved. The VGCF composites had low thermal conductivities (approximately 0.56 W/m-C) indicating they were good insulating materials. If a 65% fiber loading in VGCF composite can be achieved, then ablative properties are projected to be comparable to or better than the composite material currently used on the Space Shuttle Reusable Solid Rocket Motor (RSRM).
NASA Astrophysics Data System (ADS)
Ahmed, Nasar; Ahmed, Rizwan; Umar, Z. A.; Aslam Baig, M.
2017-08-01
In this paper we present the construction and modification of a linear time-of-flight mass spectrometer to improve its mass resolution. This system consists of a laser ablation/ionization section based on a Q-switched Nd:YAG laser (532 nm, 500 mJ, 5 ns pulse duration) integrated with a one meter linear time-of-flight mass spectrometer coupled with an electric sector and a magnetic lens and outfitted with a channeltron electron multiplier for ion detection. The resolution of the system has been improved by optimizing the accelerating potential and inserting a magnetic lens after the extraction region. The isotopes of lithium, lead and cadmium samples have been resolved and detected in accordance with their natural abundance. The capability of the system has been further exploited to determine the elemental composition of a brass alloy, having a certified composition of zinc and copper. Our results are in excellent agreement with its certified composition. This setup is found to be extremely efficient and convenient for fast analyses of any solid sample.
Quasi-dynamical analysis and real-time tissue temperature monitoring during laser vaporization
NASA Astrophysics Data System (ADS)
Wang, Hui; Ray, Aditi; Jebens, Dave; Chia, Ray; Hasenberg, Tom
2014-03-01
Vaporization and coagulation are two fundamental processes that can be performed during laser-tissue ablation. We demonstrated a method allowing quasi-dynamically observing of the cross-sectional images of tissue response during ablation. The results showed that coagulation depth is relatively constant during vaporization, which supports the excellent hemostasis of green laser benign prostate hyperplasia (BPH) treatment. We also verified a new technology for real-time, in situ tissue temperature monitoring, which may be promising for in vivo tissue vaporization degree feedback during laser ablation to improve the vaporization efficiency and avoid complications.
Trejos, Tatiana; Montero, Shirly; Almirall, José R
2003-08-01
The discrimination potential of Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) is compared with previously reported solution ICP-MS methods using external calibration (EC) with internal standardization and a newly reported solution isotope dilution (ID) method for the analysis of two different glass populations. A total of 91 different glass samples were used for the comparison study; refractive index and elemental composition were measured by the techniques mentioned above. One set consisted of 45 headlamps taken from a variety of automobiles that represents a range of 20 years of manufacturing dates. A second set consisted of 46 automotive glasses (side windows, rear windows, and windshields) representing casework glass from different vehicle manufacturers over several years. The element menu for the LA-ICP-MS and EC-ICP-MS methods include Mg, Al, Ca, Mn, Ce, Ti, Zr, Sb, Ga, Ba, Rb, Sm, Sr, Hf, La, and Pb. The ID method was limited to the analysis of two isotopes each of Mg, Sr, Zr, Sb, Ba, Sm, Hf, and Pb. Laser ablation analyses were performed with a Q switched Nd:YAG, 266 nm, 6 mJ output energy laser. The laser was used in depth profile mode while sampling using a 50 microm spot size for 50 sec at 10 Hz (500 shots). The typical bias for the analysis of NIST 612 by LA-ICP-MS was less than 5% in all cases and typically better than 5% for most isotopes. The precision for the vast majority of the element menu was determined generally less than 10% for all the methods when NIST 612 was measured (40 microg x g(-1)). Method detection limits (MDL) for the EC and LA-ICP-MS methods were similar and generally reported as less than 1 microg x g(-1) for the analysis of NIST 612. While the solution sample introduction methods using EC and ID presented excellent sensitivity and precision, these methods have the disadvantages of destroying the sample, and also involve complex sample preparation. The laser ablation method was simpler, faster, and produced comparable discrimination to the EC-ICP-MS and ID-ICP-MS. LA-ICP-MS can offer an excellent alternative to solution analysis of glass in forensic casework samples.
High resolution analysis of trace elements in corals by laser ablation ICP-MS
NASA Astrophysics Data System (ADS)
Sinclair, Daniel J.; Kinsley, Leslie P. J.; McCulloch, Malcolm T.
1998-06-01
A method has been developed using laser ablation inductively-coupled plasma mass spectrometry (LA-ICP-MS) for rapid high resolution analysis of B, Mg, Sr, Ba, and U in corals. Corals represent a challenge for a microbeam technique due to their compositional and structural heterogeneity, their nonsilicate matrix, and their unusual range of trace element compositions relative to available standards. The method employs an argon-fluoride excimer laser (λ = 193 nm), masked to produce a beam 600 μm wide by 20 μm across to average ablation sampling over a range of structural features. Coral sections are scanned at a constant rate beneath the laser to produce a continuous sampling of the coral surface. Sensitivity drift is controlled by careful preconditioning of the ICP-MS to carbonate material, and standardisation is carried out by bracketing each traverse down the coral sample by analyses of a CaSiO 3 glass synthesised from coral powder. The method demonstrates excellent reproducibility of both the shape and magnitude of coralline trace element profiles, with typical precisions of between 1.0 and 3.7% based on analysis of the synthetic standard. Accuracy varies between 3.8% for B and 31% for U. Discrepancies are attributed to heterogeneities in the synthetic standard, and matrix differences between the silicate standard and carbonate sample. The method is demonstrated by analysis of a coral collected from Australia's Great Barrier Reef near a weather station recording in-situ sea-surface-temperature (SST). The elements B, Mg, Sr, and U show seasonal compositional cycles, and tentative calibrations against SST have been derived. Using independent ICP-MS solution estimates of the coral composition to correct for standardisation uncertainties, the following calibrations have been derived: B/Ca (μmol/mol)= 1000 (±20)- 20.6 (±0.8)× SSTMg/Ca (mmol/mol)= 0.0 (±0.3)+ 0.16 (±0.01)× SSTSr/Ca (mmol/mol)= 10.8 (±0.1)- 0.070 (±0.004)× SSTU/Ca (μmol/mol)= 2.24 (±0.07)- 0.046 (±0.003)× SSTl These calibrations agree with literature within experimental errors, except for Mg which displays a 35% greater temperature dependence than reported previously. None of the elements in the coral appear to be sensitive to decreases in salinity associated with heavy rainfall in the summer of 1991/1992.
Novel Low-Density Ablators Containing Hyperbranched Poly(azomethine)s
NASA Technical Reports Server (NTRS)
Tigelaar, Dean
2011-01-01
An ablative composite is low-density (0.25 to 0.40 g/cu cm), easy to fabricate, and superior to the current state-of-the-art ablator (phenolic impregnated carbon ablator, PICA) in terms of decomposition temperature, char yield, and mechanical strength. Initial ablative testing with a CO2 laser under high-heat-flux (1,100 W/sq cm) conditions showed these new ablators are over twice as effective as PICA in terms of weight loss, as well as transfer of heat through the specimen. The carbon fiber/poly(azomethine) composites have the same density as PICA, but are 8 to 11 times stronger to irreversible breaking by tensile compression. In addition, polyazomethine char yields by thermogravimetric analysis are 70 to 80 percent at 1,000 C. This char yield is 10 to 20 percent higher than phenolic resins, as well as one of the highest char yields known for any polymer. A high char yield holds the composite together better toward shearing forces on reentry, as well as reradiates high heat fluxes. This innovative composite is stronger than PICA, so multiple pieces can be sealed together without fracture. Researchers have also studied polyazomethines before as linear polymers. Due to poor solubility, these polymers precipitate from the polymerization solvent as a low-molecular-weight (2 to 4 repeat units) powder. The only way found to date to keep linear polyazomethines in solution is by adding solubilizing side groups. However, these groups sacrifice certain polymer properties. These hyperbranched polyazomethines are high molecular weight and fully aromatic.
Experimental investigation of the laser ablation process on wood surfaces
NASA Astrophysics Data System (ADS)
Panzner, M.; Wiedemann, G.; Henneberg, K.; Fischer, R.; Wittke, Th.; Dietsch, R.
1998-05-01
Processing of wood by conventional mechanical tools like saws or planes leaves behind a layer of squeezed wood only slightly adhering to the solid wood surface. Laser ablation of this layer could improve the durability of coatings and glued joints. For technical applications, thorough knowledge about the laser ablation process is necessary. Results of ablation experiments by excimer lasers, Nd:YAG lasers, and TEA-CO 2 lasers on surfaces of different wood types and cut orientations are shown. The process of ablation was observed by a high-speed camera system and optical spectroscopy. The influence of the experimental parameters are demonstrated by SEM images and measurement of the ablation rate depending on energy density. Thermal effects like melting and also carbonizing of cellulose were found for IR- and also UV-laser wavelengths. Damage of the wood surface after laser ablation was weaker for excimer lasers and CO 2-TEA lasers. This can be explained by the high absorption of wood in the ultraviolet and middle infrared spectral range. As an additional result, this technique provides an easy way for preparing wood surfaces with excellently conserved cellular structure.
Tutton, Sean; Olson, Erik; King, David; Shaker, Joseph L
2012-10-01
Tumor-induced osteomalacia is a rare condition usually caused by benign mesenchymal tumors. When the tumor can be found, patients are usually managed by wide excision of the tumor. We report a 51-yr-old male with clinical and biochemical evidence of tumor-induced osteomalacia caused by a mesenchymal tumor in the right iliac bone. He declined surgery and appears to have been successfully managed by computed tomography-guided percutaneous ethanol ablation and percutaneous cryoablation. Our patient appears to have had an excellent clinical and biochemical response to computed tomography-guided percutaneous ethanol ablation and percutaneous cryoablation. We found one prior case of image-guided ablation using radiofrequency ablation for tumor-induced osteomalacia. Although the standard treatment for tumor-induced osteomalacia is wide excision of the tumor, image-guided ablation may be an option in patients who cannot have appropriate surgery or who decline surgery.
Anti-fouling response of gold-carbon nanotubes composite for enhanced ethanol electrooxidation
NASA Astrophysics Data System (ADS)
Sai Siddhardha, R. S.; Anupam Kumar, Manne; Lakshminarayanan, V.; Ramamurthy, Sai Sathish
2014-12-01
We report the synthesis of gold carbon nanotubes composite through a one-pot surfactant free approach and its utility for ethanol electrooxidation reaction (EOR). The method involves the application of laser ablation for nanoparticle synthesis and simultaneous assembly of these on carbon nanotubes. The catalyst has been characterized by field emission scanning electron microscopy (FESEM), energy dispersive X-ray analysis (EDAX) and UV-vis spectroscopic techniques. A systematic study of gold carbon nanotubes modified carbon paste electrode for EOR has been pursued. The kinetic study revealed the excellent stability of the modified electrode even after 200 cycles of EOR and with an Arrhenius energy as low as ∼28 kJ mol-1. Tafel slopes that are the measure of electrode activity have been monitored as a function of temperature of the electrolyte. The results indicate that despite an increase in the reaction rate with temperature, the electrode surface has not been significantly passivated by carbonaceous species produced at high temperatures.
Palussière, J; Catena, V; Buy, X
2017-09-01
Main indications of percutaneous pulmonary thermal ablation are early stage non-small cell lung carcinoma (NSCLC) for patients who are not amenable to surgery and slow-evolving localized metastatic disease, either spontaneous or following a general treatment. Radiofrequency ablation (RFA) is the most evaluated technique. This technique offers a local control rate ranging between 80 and 90% for tumors <3cm in diameter. Other more recently used ablation techniques such as microwaves and cryotherapy could overcome some limitations of RFA. One common characteristic of these techniques is an excellent tolerance with very few complications. This article reviews the differences between these techniques when applied to lung tumors, indications, results and complications. Future potential associations with immunotherapy will be discussed. Copyright © 2017. Published by Elsevier Masson SAS.
Sehar, Nandini; Mears, Jennifer; Bisco, Susan; Patel, Sandeep; Lachman, Nirusha; Asirvatham, Samuel J
2010-01-01
After initial documentation of excellent efficacy with radiofrequency ablation, this procedure is being performed increasingly in more complex situations and for more difficult arrhythmia. In these circumstances, an accurate knowledge of the anatomic basis for the ablation procedure will help maintain this efficacy and improve safety. In this review, we discuss the relevant anatomy for electrophysiology interventions for typical right atrial flutter, atrial fibrillation, and outflow tract ventricular tachycardia. In the pediatric population, maintaining safety is a greater challenge, and here again, knowing the neighboring and regional anatomy of the arrhythmogenic substrate for these arrhythmias may go a long way in preventing complications. PMID:20811537
d'Abzac, Francois-Xavier; Beard, Brian L; Czaja, Andrew D; Konishi, Hiromi; Schauer, James J; Johnson, Clark M
2013-12-17
The need for femtosecond laser ablation (fs-LA) systems coupled to MC-ICP-MS to accurately perform in situ stable isotope analyses remains an open question, because of the lack of knowledge concerning ablation-related isotopic fractionation in this regime. We report the first iron isotope analysis of size-resolved, laser-induced particles of natural magnetite, siderite, pyrrhotite, and pyrite, collected through cascade impaction, followed by analysis by solution nebulization MC-ICP-MS, as well as imaging using electron microscopy. Iron mass distributions are independent of mineralogy, and particle morphology includes both spheres and agglomerates for all ablated phases. X-ray spectroscopy shows elemental fractionation in siderite (C-rich agglomerates) and pyrrhotite/pyrite (S-rich spheres). We find an increase in (56)Fe/(54)Fe ratios of +2‰, +1.2‰, and +0.8‰ with increasing particle size for magnetite, siderite, and pyrrhotite, respectively. Fe isotope differences in size-sorted aerosols from pyrite ablation are not analytically resolvable. Experimental data are discussed using models of particles generation by Hergenröder and elemental/isotopic fractionation by Richter. We interpret the isotopic fractionation to be related to the iron condensation time scale, dependent on its saturation in the gas phase, as a function of mineral composition. Despite the isotopic variations across aerosol size fractions, total aerosol composition, as calculated from mass balance, confirms that fs-LA produces a stoichiometric sampling in terms of isotopic composition. Specifically, both elemental and isotopic fractionation are produced by particle generation processes and not by femtosecond laser-matter interactions. These results provide critical insights into the analytical requirements for laser-ablation-based stable isotope measurements of high-precision and accuracy in geological samples, including the importance of quantitative aerosol transport to the ICP.
Study of low-cost fabrication of ablative heat shields
NASA Technical Reports Server (NTRS)
Norwood, L. B.
1972-01-01
The major objectives were accomplished in three tasks: (1) modification of the ablative material composition for ease of fabrication as well as thermal and mechanical performance; (2) scaled-up, simplified, manufacturing techniques which resulted in cost reductions; and (3) the identification of a significant design problem caused by the differential pressure buildup imposed on mechanically attached ablative heat shield panels during launch.
CuInGaSe{sub 2} nanoparticles by pulsed laser ablation in liquid medium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendivil, M.I.; García, L.V.; Krishnan, B.
2015-12-15
Highlights: • CIGS nanocolloids were synthesized using PLAL technique. • Characterized their morphology, structure, composition and optical properties. • Morphologies were dependent on ablation wavelength and liquid medium. • Optical absorption and bandgap of these nanocolloids were tunable. - Abstract: Pulsed laser ablation in liquid medium (PLALM) is a nanofabrication technique to produce complex nanostructures. CuInGaSe{sub 2} (CIGS) is an alloy with applications in photovoltaic industry. In this work, we studied the effects of laser ablation wavelength, energy fluence and liquid medium on the properties of the CIGS nanoparticles synthesized by PLALM. The nanoparticles obtained were analyzed by transmission electronmore » microscopy (TEM), energy dispersive X-ray spectroscopy (EDX), selected area electron diffraction (SAED), X-ray photoelectron spectroscopy (XPS) and UV–vis absorption spectroscopy. XPS results confirmed the chemical states and composition of the ablated products. TEM analysis showed different morphologies for the nanomaterials obtained in different liquid media and ablation wavelengths. The optical properties for these CIGS nanocolloids were analyzed using UV–vis absorption spectroscopy. The results demonstrated the use of PLALM as a useful synthesis technique for nanoparticles of quaternary photovoltaic materials.« less
The Degradation Behavior of SiCf/SiO2 Composites in High-Temperature Environment
NASA Astrophysics Data System (ADS)
Yang, Xiang; Cao, Feng; Qing, Wang; Peng, Zhi-hang; Wang, Yi
2018-04-01
SiCf/SiO2 composites had been fabricated efficiently by Sol-Gel method. The oxidation behavior, thermal shock property and ablation behavior of SiCf/SiO2 composites was investigated. SiCf/SiO2 composites showed higher oxidation resistance in oxidation atmosphere, the flexural strength retention ratio was larger than 90.00%. After 1300 °C thermal shock, the mass retention ratio was 97.00%, and the flexural strength retention ratio was 92.60%, while after 1500 °C thermal shock, the mass retention ratio was 95.37%, and the flexural strength retention ratio was 83.34%. After 15 s ablation, the mass loss rate was 0.049 g/s and recession loss rate was 0.067 mm/s. The SiO2 matrix was melted in priority and becomes loosen and porous. With the ablation going on, the oxides were washed away by the shearing action of the oxyacetylene flame. The evaporation of SiO2 took away large amount of heat, which is also beneficial to the protection for SiCf/SiO2 composites.
Hachiya, Hitoshi; Yamauchi, Yasuteru; Iesaka, Yoshito; Yagishita, Atsuhiko; Sasaki, Takeshi; Higuchi, Koji; Kawabata, Mihoko; Sugiyama, Koji; Tanaka, Yasuaki; Kusa, Shigeki; Nakamura, Hiroaki; Miyazaki, Shinsuke; Taniguchi, Hiroshi; Isobe, Mitsuaki; Hirao, Kenzo
2013-10-01
Although coronary cusp (CC) ventricular arrhythmia (VA) can be treated by catheter ablation, reliable indicators of successful ablation sites have not been fully identified. This study comprised 392 patients undergoing radiofrequency catheter ablation for outflow tract-VA at 3 institutions from January 2007 to August 2012. The successful ablation site was on the left CC or right CC in 35 (8.9%) of the 392 patients. In 9 (26%) of these 35 patients, a discrete prepotential was recognized, 5 of whom had left CC-VAs and 4 of whom had right CC-VAs. Radiofrequency catheter ablation was successful at the site of the prepotential in all 9 of these patients. The duration of the isoelectric line between the end of the discrete prepotential and the onset of the ventricular electrogram was 27±13 ms. The time from onset of the discrete prepotential at the successful ablation site on the CC to the QRS onset (activation time) was 69±20 ms (range, 50-98 ms). Pace mapping was graded as excellent at the successful ablation site in only 1 patient. No discrete prepotential was recorded in any successful right outflow tract-VA ablation case in this study. A discrete prepotential was seen in 9 (26%) of 35 patients with CC-VA. In left and right CC-VA, the site of a discrete prepotential with ≥50 ms activation time may indicate a successful ablation site.
Recent Advances in Tumor Ablation for Hepatocellular Carcinoma
Kang, Tae Wook; Rhim, Hyunchul
2015-01-01
Image-guided tumor ablation for early stage hepatocellular carcinoma (HCC) is an accepted non-surgical treatment that provides excellent local tumor control and favorable survival benefit. This review summarizes the recent advances in tumor ablation for HCC. Diagnostic imaging and molecular biology of HCC has recently undergone marked improvements. Second-generation ultrasonography (US) contrast agents, new computed tomography (CT) techniques, and liver-specific contrast agents for magnetic resonance imaging (MRI) have enabled the early detection of smaller and inconspicuous HCC lesions. Various imaging-guidance tools that incorporate imaging-fusion between real-time US and CT/MRI, that are now common for percutaneous tumor ablation, have increased operator confidence in the accurate targeting of technically difficult tumors. In addition to radiofrequency ablation (RFA), various therapeutic modalities including microwave ablation, irreversible electroporation, and high-intensity focused ultrasound ablation have attracted attention as alternative energy sources for effective locoregional treatment of HCC. In addition, combined treatment with RFA and chemoembolization or molecular agents may be able to overcome the limitation of advanced or large tumors. Finally, understanding of the biological mechanisms and advances in therapy associated with tumor ablation will be important for successful tumor control. All these advances in tumor ablation for HCC will result in significant improvement in the prognosis of HCC patients. In this review, we primarily focus on recent advances in molecular tumor biology, diagnosis, imaging-guidance tools, and therapeutic modalities, and refer to the current status and future perspectives for tumor ablation for HCC. PMID:26674766
Microscopic Scale Simulation of the Ablation of Fibrous Materials
NASA Technical Reports Server (NTRS)
Lachaud, Jean Romain; Mansour, Nagi N.
2010-01-01
Ablation by oxidation of carbon-fiber preforms impregnated in carbonized phenolic matrix is modeled at microscopic scale. Direct numerical simulations show that the carbonized phenolic matrix ablates in volume leaving the carbon fibers exposed. This is due to the fact that the reactivity of carbonized phenolic is higher than the reactivity of carbon fibers. After the matrix is depleted, the fibers ablate showing progressive reduction of their diameter. The overall material recession occurs when the fibers are consumed. Two materials with the same carbon-fiber preform, density and chemical composition, but with different matrix distributions are studied. These studies show that at moderate temperatures (< 1000 K) the microstructure of the material influences its recession rate; a fact that is not captured by current models that are based on chemical composition only. Surprisingly, the response of these impregnated-fiber materials is weakly dependent on the microstructure at very high temperatures (e.g., Stardust peak heating conditions: 3360K).
Production of microscale particles from fish bone by gas flow assisted laser ablation
NASA Astrophysics Data System (ADS)
Boutinguiza, M.; Lusquiños, F.; Comesaña, R.; Riveiro, A.; Quintero, F.; Pou, J.
2007-12-01
Recycled wastes from fish and seafood can constitute a source of precursor material for different applications in the biomedical field such as bone fillers or precursor material for bioceramic coatings to improve the osteointegration of metallic implants. In this work, fish bones have been used directly as target in a laser ablation system. A pulsed Nd:YAG laser was used to ablate the fish bone material and a transverse air flow was used to extract the ablated material out of the interaction zone. The particles collected at a filter were in the micro and nanoscale range. The morphology as well as the composition of the obtained particles were characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX) and transmission electron microscopy (TEM). The results reveal that the composition of the analyzed particles is similar to that of the inorganic part of the fish bone.
NASA Astrophysics Data System (ADS)
Almirall, Jose R.; Trejos, Tatiana; Hobbs, Andria; Furton, Kenneth G.
2003-09-01
The importance of small amounts of glass and paint evidence as a means to associate a crime event to a suspect or a suspect to another individual has been demonstrated in many cases. Glass is a fragile material that is often found at the scenes of crimes such as burglaries, hit-and-run accidents and violent crime offenses. Previous work has demonstrated the utility of elemental analysis by solution ICP-MS of small amounts of glass for the comparison between a fragment found at a crime scene to a possible source of the glass. The multi-element capability and the sensitivity of ICP-MS combined with the simplified sample introduction of laser ablation prior to ion detection provides for an excellent and relatively non-destructive technique for elemental analysis of glass fragments. The direct solid sample introduction technique of laser ablation (LA) is reported as an alternative to the solution method. Direct solid sampling provides several advantages over solution methods and shows great potential for a number of solid sample analyses in forensic science. The advantages of laser ablation include the simplification of sample preparation, thereby reducing the time and complexity of the analysis, the elimination of handling acid dissolution reagents such as HF and the reduction of sources of interferences in the ionization plasma. Direct sampling also provides for essentially "non-destructive" sampling due to the removal of very small amounts of sample needed for analysis. The discrimination potential of LA-ICP-MS is compared with previously reported solution ICP-MS methods using external calibration with internal standardization and a newly reported solution isotope dilution (ID) method. A total of ninety-one different glass samples were used for the comparison study using the techniques mentioned. One set consisted of forty-five headlamps taken from a variety of automobiles representing a range of twenty years of manufacturing dates. A second set consisted of forty-six automotive glasses (side windows and windshields) representing casework glass from different vehicle manufacturers over several years was also characterized by RI and elemental composition analysis. The solution sample introduction techniques (external calibration and isotope dilution) provide for excellent sensitivity and precision but have the disadvantages of destroying the sample and also involve complex sample preparation. The laser ablation method was simpler, faster and produced comparable discrimination to the EC-ICP-MS and ID-ICP-MS. LA-ICP-MS can provide for an excellent alternative to solution analysis of glass in forensic casework samples. Paints and coatings are frequently encountered as trace evidence samples submitted to forensic science laboratories. A LA-ICP-MS method has been developed to complement the commonly used techniques in forensic laboratories in order to better characterize these samples for forensic purposes. Time-resolved plots of each sample can be compared to associate samples to each other or to discriminate between samples. Additionally, the concentration of lead and the ratios of other elements have been determined in various automotive paints by the reported method. A sample set of eighteen (18) survey automotive paint samples have been analyzed with the developed method in order to determine the utility of LA-ICP-MS and to compare the method to the more commonly used scanning electron microscopy (SEM) method for elemental characterization of paint layers in forensic casework.
Ablative material testing for low-pressure, low-cost rocket engines
NASA Technical Reports Server (NTRS)
Richter, G. Paul; Smith, Timothy D.
1995-01-01
The results of an experimental evaluation of ablative materials suitable for the production of light weight, low cost rocket engine combustion chambers and nozzles are presented. Ten individual specimens of four different compositions of silica cloth-reinforced phenolic resin materials were evaluated for comparative erosion in a subscale rocket engine combustion chamber. Gaseous hydrogen and gaseous oxygen were used as propellants, operating at a nominal chamber pressure of 1138 kPa (165 psi) and a nominal mixture ratio (O/F) of 3.3. These conditions were used to thermally simulate operation with RP-1 and liquid oxygen, and achieved a specimen throat gas temperature of approximately 2456 K (4420 R). Two high-density composition materials exhibited high erosion resistance, while two low-density compositions exhibited approximately 6-75 times lower average erosion resistance. The results compare favorably with previous testing by NASA and provide adequate data for selection of ablatives for low pressure, low cost rocket engines.
NASA Astrophysics Data System (ADS)
Wu, M. L.; Ren, C. Z.; Xu, H. Z.
2016-11-01
The coefficient of thermal conductivity was influenced by the wetting state of material. The wetting state usually depends on the surface wettability. C/SiC is a promising ceramic composites with multi-components. The wettability of C/SiC composites is hard to resort to the classical wetting theory directly. So far, few investigations focused on C/SiC surface wettability diversity after different material removal processes. In this investigation, comparative studies of surface wettability of ground C/SiC surface and laser-ablated C/SiC surface were carried out through apparent contact angle (APCA) measurements. The results showed that water droplets easily reached stable state on ground C/SiC surface; while the water droplets rappidly penetrated into the laser-ablated C/SiC surface. In order to find out the reason for wettability distinctions between the ground C/SiC surface and the laser-ablated C/SiC surface, comparative studies on the surface micro-structure, surface C-O-Si distribution, and surface C-O-Si weight percentage were carried out. The results showed that (1) A large number of micro cracks in the fuzzy pattern layer over laser-ablated C/SiC surfaces easily destoried the surface tension of water droplets, while only a few cracks existed over the ground C/SiC surfaces. (2) Chemical components (C, O, Si) were non-uniformly distributed on ground C/SiC surfaces, while the chemical components (C, O, Si) were uniformly distributed on laser-ablated C/SiC surfaces. (3) The carbon weight percentage on ground C/SiC surfaces were higher than that on laser-ablated C/SiC surfaces. All these made an essential contribution to the surface wettability diversity of C/SiC surface. Although more investigations about the quantitative influence of surface topography and surface chemical composition on composites wettability are still needed, the conslusion can be used in application: the wettability of C/SiC surface can be controlled by different material removal process without individual following up surface modification process.
Femtosecond Laser Ablated FBG with Composite Microstructure for Hydrogen Sensor Application.
Zou, Meng; Dai, Yutang; Zhou, Xian; Dong, Ke; Yang, Minghong
2016-12-01
A composite microstructure in fiber Bragg grating (FBG) with film deposition for hydrogen detection is presented. Through ablated to FBG cladding by a femtosecond laser, straight-trenches and spiral micro-pits are formed. A Pd-Ag film is sputtered on the surface of the laser processed FBG single mode fiber, and acts as hydrogen sensing transducer. The demonstrated experimental outcomes show that a composite structure produced the highest sensitivity of 26.3 pm/%H, nearly sevenfold more sensitive compared with original standard FBG. It offers great potential in engineering applications for its good structure stability and sensitivity.
Bonekamp, David; Wolf, M B; Roethke, M C; Pahernik, S; Hadaschik, B A; Hatiboglu, G; Kuru, T H; Popeneciu, I V; Chin, J L; Billia, M; Relle, J; Hafron, J; Nandalur, K R; Staruch, R M; Burtnyk, M; Hohenfellner, M; Schlemmer, H-P
2018-06-25
To quantitatively assess 12-month prostate volume (PV) reduction based on T2-weighted MRI and immediate post-treatment contrast-enhanced MRI non-perfused volume (NPV), and to compare measurements with predictions of acute and delayed ablation volumes based on MR-thermometry (MR-t), in a central radiology review of the Phase I clinical trial of MRI-guided transurethral ultrasound ablation (TULSA) in patients with localized prostate cancer. Treatment day MRI and 12-month follow-up MRI and biopsy were available for central radiology review in 29 of 30 patients from the published institutional review board-approved, prospective, multi-centre, single-arm Phase I clinical trial of TULSA. Viable PV at 12 months was measured as the remaining PV on T2-weighted MRI, less 12-month NPV, scaled by the fraction of fibrosis in 12-month biopsy cores. Reduction of viable PV was compared to predictions based on the fraction of the prostate covered by the MR-t derived acute thermal ablation volume (ATAV, 55°C isotherm), delayed thermal ablation volume (DTAV, 240 cumulative equivalent minutes at 43°C thermal dose isocontour) and treatment-day NPV. We also report linear and volumetric comparisons between metrics. After TULSA, the median 12-month reduction in viable PV was 88%. DTAV predicted a reduction of 90%. Treatment day NPV predicted only 53% volume reduction, and underestimated ATAV and DTAV by 36% and 51%. Quantitative volumetry of the TULSA phase I MR and biopsy data identifies DTAV (240 CEM43 thermal dose boundary) as a useful predictor of viable prostate tissue reduction at 12 months. Immediate post-treatment NPV underestimates tissue ablation. • MRI-guided transurethral ultrasound ablation (TULSA) achieved an 88% reduction of viable prostate tissue volume at 12 months, in excellent agreement with expectation from thermal dose calculations. • Non-perfused volume on immediate post-treatment contrast-enhanced MRI represents only 64% of the acute thermal ablation volume (ATAV), and reports only 60% (53% instead of 88% achieved) of the reduction in viable prostate tissue volume at 12 months. • MR-thermometry-based predictions of 12-month prostate volume reduction based on 240 cumulative equivalent minute thermal dose volume are in excellent agreement with reduction in viable prostate tissue volume measured on pre- and 12-month post-treatment T2w-MRI.
Yeo, Sin Yuin; Kim, Young-Sun; Lim, Hyo Keun; Rhim, Hyunchul; Jung, Sin-Ho; Hwang, Na Young
2017-12-01
To investigate the influence of a high-signal-intensity peripheral rim on T2-weighted MR images (i.e., T2-rim sign) on the immediate therapeutic responses of MR-guided high intensity focused ultrasound (MR-HIFU) ablation of uterine fibroids. This retrospective study was approved by the institutional review board, and patient informed consent was obtained for MR-HIFU ablation. In total, 196 fibroids (diameter 6.2±2.6cm) in 123 women (age 43.4±5.0 years) who underwent MR-HIFU ablation from January 2013 to April 2016 were included. The effects of a T2-rim sign on the immediate therapeutic responses (non-perfused volume [NPV] ratio, ablation efficiency [NPV/treatment cell volume], ablation quality [grade 1-5, poor to excellent]) were investigated with univariable and multivariable analyses using generalized estimating equation (GEE) analysis. In multivariable analysis, T2 signal intensity ratio of fibroids-to-skeletal muscle, relative peak enhancement of fibroids, and subcutaneous fat thickness were also considered. The presence of a T2-rim sign significantly lowered the NPV ratio (54.0±28.0% vs. 83.7±17.7%), ablation efficiency (0.6±0.5 vs. 1.3±0.6), ablation quality (3.1±1.2 vs. 4.2±0.8), (P<0.0001). GEE analysis showed that the presence of a T2-rim sign was independently significant for ablation efficiency and ablation quality (P<0.05). Uterine fibroids with a T2-rim sign showed significantly poorer immediate therapeutic responses to MR-HIFU ablation. Copyright © 2017 Elsevier B.V. All rights reserved.
Schelle, Florian; Polz, Sebastian; Haloui, Hatim; Braun, Andreas; Dehn, Claudia; Frentzen, Matthias; Meister, Jörg
2014-11-01
Modern ultrashort pulse lasers with scanning systems provide a huge set of parameters affecting the suitability for dental applications. The present study investigates thresholds and ablation rates of oral hard tissues and restorative materials with a view towards a clinical application system. The functional system consists of a 10 W Nd:YVO4 laser emitting pulses with a duration of 8 ps at 1,064 nm. Measurements were performed on dentin, enamel, ceramic, composite, and mammoth ivory at a repetition rate of 500 kHz. By employing a scanning system, square-shaped cavities with an edge length of 1 mm were created. Ablation threshold and rate measurements were assessed by variation of the applied fluence. Examinations were carried out employing a scanning electron microscope and optical profilometer. Irradiation time was recorded by the scanner software in order to calculate the overall ablated volume per time. First high power ablation rate measurements were performed employing a laser source with up to 50 W. Threshold values in the range of 0.45 J/cm(2) (composite) to 1.54 J/cm(2) (enamel) were observed. Differences between any two materials are statistically significant (p < 0.05). Preparation speeds up to 37.53 mm(3)/min (composite) were achieved with the 10 W laser source and differed statistically significant for any two materials (p < 0.05) with the exception of dentin and mammoth ivory (p > 0.05). By employing the 50 W laser source, increased rates up to ∼50 mm(3)/min for dentin were obtained. The results indicate that modern USPL systems provide sufficient ablation rates to be seen as a promising technology for dental applications.
Novel Experimental Simulations of the Atmospheric Injection of Meteoric Metals
NASA Astrophysics Data System (ADS)
Gómez Martín, J. C.; Bones, D. L.; Carrillo-Sánchez, J. D.; James, A. D.; Trigo-Rodríguez, J. M.; Fegley, B., Jr.; Plane, J. M. C.
2017-02-01
A newly developed laboratory, Meteoric Ablation Simulator (MASI), is used to test model predictions of the atmospheric ablation of interplanetary dust particles (IDPs) with experimental Na, Fe, and Ca vaporization profiles. MASI is the first laboratory setup capable of performing time-resolved atmospheric ablation simulations, by means of precision resistive heating and atomic laser-induced fluorescence detection. Experiments using meteoritic IDP analogues show that at least three mineral phases (Na-rich plagioclase, metal sulfide, and Mg-rich silicate) are required to explain the observed appearance temperatures of the vaporized elements. Low melting temperatures of Na-rich plagioclase and metal sulfide, compared to silicate grains, preclude equilibration of all the elemental constituents in a single melt. The phase-change process of distinct mineral components determines the way in which Na and Fe evaporate. Ca evaporation is dependent on particle size and on the initial composition of the molten silicate. Measured vaporized fractions of Na, Fe, and Ca as a function of particle size and speed confirm differential ablation (I.e., the most volatile elements such as Na ablate first, followed by the main constituents Fe, Mg, and Si, and finally the most refractory elements such as Ca). The Chemical Ablation Model (CABMOD) provides a reasonable approximation to this effect based on chemical fractionation of a molten silicate in thermodynamic equilibrium, even though the compositional and geometric description of IDPs is simplistic. Improvements in the model are required in order to better reproduce the specific shape of the elemental ablation profiles.
System and process for dissolution of solids
Liezers, Martin; Farmer, III, Orville T.
2017-10-10
A system and process are disclosed for dissolution of solids and "difficult-to-dissolve" solids. A solid sample may be ablated in an ablation device to generate nanoscale particles. Nanoparticles may then swept into a coupled plasma device operating at atmospheric pressure where the solid nanoparticles are atomized. The plasma exhaust may be delivered directly into an aqueous fluid to form a solution containing the atomized and dissolved solids. The composition of the resulting solution reflects the composition of the original solid sample.
Low work function surface layers produced by laser ablation using short-wavelength photons
Balooch, Mehdi; Dinh, Long N.; Siekhaus, Wigbert J.
2000-01-01
Short-wavelength photons are used to ablate material from a low work function target onto a suitable substrate. The short-wavelength photons are at or below visible wavelength. The elemental composition of the deposit is controlled by the composition of the target and the gaseous environment in which the ablation process is performed. The process is carried out in a deposition chamber to which a short-wavelength laser is mounted and which includes a substrate holder which can be rotated, tilted, heated, or cooled. The target material is mounted onto a holder that spins the target during laser ablation. In addition, the deposition chamber is provided with a vacuum pump, an external gas supply with atomizer and radical generator, a gas generator for producing a flow of molecules on the substrate, and a substrate cleaning device, such as an ion gun. The substrate can be rotated and tilted, for example, whereby only the tip of an emitter can be coated with a low work function material.
Hong, Baoan; Du, Xin; Zhao, Yuan; Chen, Guowei; Zhang, Xiaodong; Zhang, Ning; Yang, Yong
2015-01-01
A model of in vivo porcine kidneys is used to clarify the characteristics of laparoscopic microwave ablation (MWA) of renal tissue. Six pigs were utilised for the experiment using 18G water circulating-cooling microwave needles. The operating frequency was 2450 MHz, and the independent variables were power (50-60 W) and time (300-600 s). The kidneys were dissociated laparoscopically and ablated with a single or double needle at different power/time combinations and depths of puncture. Changes in the kidneys were carefully observed. Specimens of the ablated lesions were stained with haematoxylin-eosin (H&E) to evaluate the pathological features. Thirty-four thermoablations were applied. The effective ablation shape was similar to a chestnut. The ablated lesions could be divided into three zones: carbonization zone, coagulation zone, and inflammatory reaction zone. The ablation zone enlarged with increasing power and time. When combined with two needles, the maximum diameter of the ablated lesions significantly increased. Pathological results indicated that renal tissues of the carbonisation zone were thoroughly necrotic. Coagulative necrosis was observed in the coagulation zone. No 'skipped' areas were noted in any ablation zone. The structure of the inflammatory reaction zone was integrated, and interstitial small blood vessels were highly expanded and congested with infiltrated inflammatory cells. MWA achieved excellent effects in this porcine model. It can be safely and effectively used in renal tissue. For patients with poor physical condition or small renal masses (<4 cm), we can refer to these data and select the appropriate combinations to obtain satisfactory therapeutic efficacy.
Fractional CO2 lasers contribute to the treatment of stable non-segmental vitiligo.
Yuan, Jinping; Chen, Hongqiang; Yan, Ru; Cui, Shaoshan; Li, Yuan-Hong; Wu, Yan; Gao, Xing-Hua; Chen, Hong-Duo
2016-12-01
Stable non-segmental vitiligo is often resistant to conventional therapies. The purpose of this study was to investigate the effect of three types of fractional lasers in the treatment of stable non-segmental vitiligo. Twenty patients were enrolled in the study. The vitiligo lesions of each patient were divided into four treatment parts, and all parts were treated with narrowband ultraviolet-B (NB-UVB). Three of the four parts were respectively treated with three types of fractional lasers (two ablative 10,600-nm CO 2 lasers and one non-ablative 1,565-nm laser), followed by topical betamethasone solution application. The treatment period lasted six months. Efficacy and satisfaction were respectively assessed by dermatologists and patients. The ablative CO 2 lasers, in combination with topical betamethasone solution and NB-UVB, achieved marked to excellent improvement on white patches assessed by dermatologists. Patients showed high satisfaction scores for the treatments. The non-ablative 1,565-nm fractional laser did not provide any further benefit in the treatment of vitiligo. No severe adverse events developed for any of the treatments. The treatment protocol with ablative CO 2 lasers, in combination with topical betamethasone solution and NB-UVB, was suitable for stable non-segmental vitiligo. For vitiligo, the ablative fractional CO 2 laser is more effective than the non-ablative fractional laser.
NASA Astrophysics Data System (ADS)
Ahmed, Nasar; Umar, Zeshan A.; Ahmed, Rizwan; Aslam Baig, M.
2017-10-01
We present qualitative and quantitative analysis of the trace elements present in different brands of tobacco available in Pakistan using laser induced breakdown spectroscopy (LIBS) and Laser ablation Time of Flight Mass Spectrometer (LA-TOFMS). The compositional analysis using the calibration free LIBS technique is based on the observed emission spectra of the laser produced plasma plume whereas the elemental composition analysis using LA-TOFMS is based on the mass spectra of the ions produced by laser ablation. The optical emission spectra of these samples contain spectral lines of calcium, magnesium, sodium, potassium, silicon, strontium, barium, lithium and aluminum with varying intensities. The corresponding mass spectra of the elements were detected in LA-TOF-MS with their composition concentration. The analysis of different brands of cigarettes demonstrates that LIBS coupled with a LA-TOF-MS is a powerful technique for the elemental analysis of the trace elements in any solid sample.
Noble, Stephen R; Horstwood, Matthew S A; Davy, Pamela; Pashley, Vanessa; Spiro, Baruch; Smith, Steve
2008-07-01
Pb isotope compositions of biologically significant PM(10) atmospheric particulates from a busy roadside location in London UK were measured using solution- and laser ablation-mode MC-ICP-MS. The solution-mode data for PM(10) sampled between 1998-2001 document a dramatic shift to increasingly radiogenic compositions as leaded petrol was phased out. LA-MC-ICP-MS isotope analysis, piloted on a subset of the available samples, is shown to be a potential reconnaissance analytical technique. PM(10) particles trapped on quartz filters were liberated from the filter surface, without ablating the filter substrate, using a 266 nm UV laser and a dynamic, large diameter, low-fluence ablation protocol. The Pb isotope evolution noted in the London data set obtained by both analytical protocols is similar to that observed elsewhere in Western Europe following leaded petrol elimination. The data therefore provide important baseline isotope composition information useful for continued UK atmospheric monitoring through the early 21(st) century.
von Bary, Christian; Deneke, Thomas; Arentz, Thomas; Schade, Anja; Lehrmann, Heiko; Fredersdorf, Sabine; Baldaranov, Dobri; Maier, Lars; Schlachetzki, Felix
2017-01-01
Left atrial pulmonary vein isolation (PVI) is an accepted treatment option for patients with symptomatic atrial fibrillation (AF). This procedure can be complicated by stroke or silent cerebral embolism. Online measurement of microembolic signals (MESs) by transcranial Doppler (TCD) may be useful for characterizing thromboembolic burden during PVI. In this prospective multicenter trial, we investigated the burden, characteristics, and composition of MES during left atrial catheter ablation using a variety of catheter technologies. PVI was performed in a total of 42 patients using the circular-shaped multielectrode pulmonary vein ablation catheter (PVAC) technology in 23, an irrigated radiofrequency (IRF) in 14, and the cryoballoon (CB) technology in 5 patients. TCD was used to detect the total MES burden and sustained thromboembolic showers (TESs) of >30 s. During TES, the site of ablation within the left atrium was registered. MES composition was classified manually into "solid," "gaseous," or "equivocal" by off-line expert assessment. The total MES burden was higher when using IRF compared to CB (2,336 ± 1,654 vs. 593 ± 231; p = 0.007) and showed a tendency toward a higher burden when using IRF compared to PVAC (2,336 ± 1,654 vs. 1,685 ± 2,255; p = 0.08). TES occurred more often when using PVAC compared to IRF (1.5 ± 2 vs. 0.4 ± 1.3; p = 0.04) and most frequently when ablation was performed close to the left superior pulmonary vein (LSPV). Of the MES, 17.004 (23%) were characterized as definitely solid, 13.204 (18%) as clearly gaseous, and 44.366 (59%) as equivocal. We investigated the burden and characteristics of MES during left atrial catheter ablation for AF. All ablation techniques applied in this study generated a relevant number of MES. There was a significant difference in total MES burden using IRF compared to CB and a tendency toward a higher burden using IRF compared to PVAC. The highest TES burden was found in the PVAC group, particularly during ablation close to the LSPV. The composition of thromboembolic particles was balanced. The impact of MES, TES, and composition of thromboembolic particles on neurological outcome needs to be evaluated further. (Clinical Trial Registration: Deutsches Register Klinischer Studien, https://drks-neu.uniklinik-freiburg.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00003465. DRKS00003465.).
U-shaped micro-groove fiber based on femtosecond laser processing for humidity sensing
NASA Astrophysics Data System (ADS)
Fu, Gui; Ma, Li-li; Su, Fu-fang; Shi, Meng
2018-05-01
A novel optical fiber sensor with a U-shaped micro-groove structure ablated by femtosecond laser on single-mode fiber for measuring air relative humidity (RH) is reported in this paper. In order to improve the accuracy of sensor, a graphene oxide (GO)/polyvinyl alcohol (PVA) composite film is coated on the surface of micro-groove structure. In the U-shaped micro-groove structure, the remaining core and micro-cavity in the micro-groove make up two major optical propagation paths, forming a Mach-Zehnder interferometer (MZI). The sensor has a good linear response within the RH range of 30%—85%, and the maximum sensitivity can reach 0.638 1 nm/%RH. The effect of temperature on the overall performance of the humidity sensor is also investigated. As a new type of all-fiber device, the sensor shows excellent sensitivity and stability.
Fabrication of Nb/Pb structures through ultrashort pulsed laser deposition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gontad, Francisco; Lorusso, Antonella, E-mail: antonella.lorusso@le.infn.it; Perrone, Alessio
This work reports the fabrication of Nb/Pb structures with an application as photocathode devices. The use of relatively low energy densities for the ablation of Nb with ultrashort pulses favors the reduction of droplets during the growth of the film. However, the use of laser fluences in this ablation regime results in a consequent reduction in the average deposition rate. On the other hand, despite the low deposition rate, the films present a superior adherence to the substrate and an excellent coverage of the irregular substrate surface, avoiding the appearance of voids or discontinuities on the film surface. Moreover, themore » low energy densities used for the ablation favor the growth of nanocrystalline films with a similar crystalline structure to the bulk material. Therefore, the use of low ablation energy densities with ultrashort pulses for the deposition of the Nb thin films allows the growth of very adherent and nanocrystalline films with adequate properties for the fabrication of Nb/Pb structures to be included in superconducting radiofrequency cavities.« less
Song, Shu-Tao; Cui, Lan; Yang, Jing; Du, Xi-Wen
2015-01-28
As a promising material for photoelectrical application, MoS2 has attracted extensive attention on its facile synthesis and unique properties. Herein, we explored a novel strategy of laser ablation to synthesize MoS2 fullerene-like nanoparticles (FL-NPs) with stable photoresponse under high temperature. Specifically, we employed a millisecond pulsed laser to ablate the molybdenum target in dimethyl trisulfide gas, and as a result, the molybdenum nanodroplets were ejected from the target and interacted with the highly reactive ambient gas to produce MoS2 FL-NPs. In contrast, the laser ablation in liquid could only produce core-shell nanoparticles. The crucial factors for controlling final nanostructures were found to be laser intensity, cooling rate, and gas reactivity. Finally, the MoS2 FL-NPs were assembled into a simple photoresponse device which exhibited excellent thermal stability, indicating their great potentialities for high-temperature photoelectrical applications.
Cost considerations in implementing a screening and surveillance strategy for Barrett's oesophagus.
Inadomi, John M
2015-02-01
There is increasing concern over the rising costs of healthcare leading to debate regarding the use of resources to implement preventive strategies. Oesophageal adenocarcinoma and its precursor, Barrett's oesophagus provides an excellent opportunity to highlight this issue since cancer is uncommon even among individuals with documented Barrett's oesophagus. This review provides a brief introduction to economic analysis in healthcare and summarizes published studies of the cost-effectiveness of strategies to reduce mortality from cancer. Current best estimates highlight the cost-effectiveness of endoscopic ablation among patients with Barrett's oesophagus and high-grade dysplasia and the low cost-effectiveness of ablation among patients without dysplasia. The cost-effectiveness of ablation among patients with Barrett's and low-grade dysplasia is poorly defined due to the ambiguity of diagnosing dysplasia, the unknown risk of cancer among patients with low-grade dysplasia, and the uncertain durability of ablation to maintain remission from metaplasia and dysplasia and prevent cancer. Copyright © 2015 Elsevier Ltd. All rights reserved.
Merckel, Laura G; Bartels, Lambertus W; Köhler, Max O; van den Bongard, H J G Desirée; Deckers, Roel; Mali, Willem P Th M; Binkert, Christoph A; Moonen, Chrit T; Gilhuijs, Kenneth G A; van den Bosch, Maurice A A J
2013-04-01
Optimizing the treatment of breast cancer remains a major topic of interest. In current clinical practice, breast-conserving therapy is the standard of care for patients with localized breast cancer. Technological developments have fueled interest in less invasive breast cancer treatment. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a completely noninvasive ablation technique. Focused beams of ultrasound are used for ablation of the target lesion without disrupting the skin and subcutaneous tissues in the beam path. MRI is an excellent imaging method for tumor targeting, treatment monitoring, and evaluation of treatment results. The combination of HIFU and MR imaging offers an opportunity for image-guided ablation of breast cancer. Previous studies of MR-HIFU in breast cancer patients reported a limited efficacy, which hampered the clinical translation of this technique. These prior studies were performed without an MR-HIFU system specifically developed for breast cancer treatment. In this article, a novel and dedicated MR-HIFU breast platform is presented. This system has been designed for safe and effective MR-HIFU ablation of breast cancer. Furthermore, both clinical and technical challenges are discussed, which have to be solved before MR-HIFU ablation of breast cancer can be implemented in routine clinical practice.
Schoenewolf, Nicola L; Hafner, Jürg; Dummer, Reinhard; Bogdan Allemann, Inja
2015-04-01
Lentigines solares (LS) on the dorsum of hands are often esthetically disturbing. Q-switched ruby laser treatment is highly effective in the treatment of these lesions. Ablative fractional photothermolysis may be a suitable alternative. We compared the Q-switched ruby laser with ablative CO2 fractional photothermolysis for the treatment of solar lentigines. To evaluate the efficacy and side-effects of 694nm Q-switched ruby laser (Sinon) with the ablative 10,600nm CO2 fractional laser (Quantel Excel O2) in an intra-individual side-to-side comparison in the treatment of LS on the dorsum of hands. Eleven patients were included in the study. The hands of each patient were randomized for treatment with the two laser systems. Three treatment sessions were scheduled at weeks 0, 4 and 8. Evaluations by patients, treating physician and blinded experts were scheduled at weeks 0, 4, 8, 16 and 24. The Q-switched ruby laser was significantly more efficacious than the ablative CO2 fractional laser for removing LS on the dorsum of hands (p = 0.01). In this first study on this topic, the Q-switched ruby laser was superior to the ablative CO2 fractional laser in the treatment of lentigines solares on the dorsum of hands.
Preparation and Ablating Behavior of FGM used in a Heat Flux Rocket Engine
NASA Astrophysics Data System (ADS)
He, Xiaodong; Han, Jiecai; Zhang, Xinghong
2002-01-01
Functionally Graded Material (FGM) is a new kind of nonhomogeneous materials, which composition varies gradually and continuously from metals to ceramics, thus excellence of both ceramic and metal is brought fully into play. The impetus for the development of FGM was to make thermal barrier materials for space shuttles and structure such as combustion chamber, gas vane, air vane, nose cone, fuel valve sheets and piston crown. There are several main techniques for making FGMs including chemical vapor deposition (CVD), powder metallurgy, plasma spraying and self-propagating high temperate synthesis (SHS). SHS Technology is the process by which condensed phases are produced by self - sustaining exothermic chemical reaction. Demonstrated advantages of SHS as a method for the preparation of materials include higher purity of the products, low energy requirements, and the relative simplicity of the process. SHS is particularly well suited to fabricating FGM. Due to the rapidity of the combustion reaction, the initial arrangement of the constituent in the green body is unchanged during combustion. In this paper, TiB2-Cu FGM and homogeneous cermets have been prepared by combing forced compaction with SHS. The experimental results show that process parameters significantly influence the combustion synthesis procedure of Ti-B-Cu system. Optimal process parameters have been gained for preparing TiB2-Cu FGM and cermets. TiB2-Cu FGM by SHS has a continuous distribution in microstructure along its thickness. The macroscopic interface of ceramic/metal joint is elemented. Mechanical properties of TiB2-Cu cermets were investigated at room and high temperature. The thermal stress of TiC-Ni FGM prepared by SHS are simulated at working condition, as well as comparing with a layered TiB2-Cu Non- FGM. Obviously, the TiB2-Cu FGM has the function of distortion and thermal stress relation. TiB2-Cu FGM was tested in the limited wind tunnel simulating the real condition of the heat flux rocket engine. As a result, TiB2-Cu FGM showed excellent resistant ablating properties. There is only a little loss of the mass after heated for 40 seconds in the wind tunnel. Meanwhile no cracks and breakup appeared in the FGM under the sharp thermal shock condition. Key words: functionally graded materials, combustion synthesis, ablation, thermal shock, thermal stress
Novel Experimental Simulations of the Atmospheric Injection of Meteoric Metals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gómez Martín, J. C.; Bones, D. L.; Carrillo-Sánchez, J. D.
2017-02-20
A newly developed laboratory, Meteoric Ablation Simulator (MASI), is used to test model predictions of the atmospheric ablation of interplanetary dust particles (IDPs) with experimental Na, Fe, and Ca vaporization profiles. MASI is the first laboratory setup capable of performing time-resolved atmospheric ablation simulations, by means of precision resistive heating and atomic laser-induced fluorescence detection. Experiments using meteoritic IDP analogues show that at least three mineral phases (Na-rich plagioclase, metal sulfide, and Mg-rich silicate) are required to explain the observed appearance temperatures of the vaporized elements. Low melting temperatures of Na-rich plagioclase and metal sulfide, compared to silicate grains, precludemore » equilibration of all the elemental constituents in a single melt. The phase-change process of distinct mineral components determines the way in which Na and Fe evaporate. Ca evaporation is dependent on particle size and on the initial composition of the molten silicate. Measured vaporized fractions of Na, Fe, and Ca as a function of particle size and speed confirm differential ablation (i.e., the most volatile elements such as Na ablate first, followed by the main constituents Fe, Mg, and Si, and finally the most refractory elements such as Ca). The Chemical Ablation Model (CABMOD) provides a reasonable approximation to this effect based on chemical fractionation of a molten silicate in thermodynamic equilibrium, even though the compositional and geometric description of IDPs is simplistic. Improvements in the model are required in order to better reproduce the specific shape of the elemental ablation profiles.« less
Avitall, Boaz; Lafontaine, Daniel; Rozmus, Grzegorz; Adoni, Naveed; Dehnee, Abed; Urbonas, Arvydas; Le, Khoi M; Aleksonis, Dinas
2005-04-01
The coronary sinus (CS) can provide access to targets across and within the atrioventricular (AV) junction. In 12 dogs (32 +/- 3 Kg), cryo balloons (10-19 mm) were applied to regions of the AV junction for 3 minutes at a temperature of -75.9( composite function) +/- 9(composite function)C (ranging -57 to -83). Electrical activity and pacing within the CS were assessed pre and post ablation and at least 3 months later in 9 dogs. In the 3 other dogs, hearts were examined immediately after cryo ablation. CS and circumflex angiography was performed pre and post ablation. The hearts, CS, and Cx were then examined for structural injury. The AV junction was sectioned and the hearts were immersed in Tetrazolium, and the lesions were inspected for transmurality across the AV groove. In 3/12 dogs the distal CS cryo lesions resulted in inferior ST segment depression that resolved within 5 minutes. There was no arrhythmia or hemodynamic changes. No CS electrical activity was noted post ablation. The pacing threshold increased from 2 +/- 2.3 mA to 7.4 +/- 3.6 mA (p < 0.001). Pathological examination of 3 acute hearts revealed hematomas. There was no pericardial effusion. No evidence of stenosis or thrombosis was seen within the CS and the circumflex artery. After 3 months of recovery, transmural lesions across the AV groove were present in all of the targeted AV regions. Intra-CS cryo balloon ablation is safe and can potentially replace endocardial RF ablation targeting the AV junction and the CS muscular sleeve.
NASA Astrophysics Data System (ADS)
Sai Siddhardha, R. S.; Lakshman Kumar, V.; Kaniyoor, Adarsh; Sai Muthukumar, V.; Ramaprabhu, S.; Podila, Ramakrishna; Rao, A. M.; Ramamurthy, Sai Sathish
2014-12-01
A facile surfactant free laser ablation mediated synthesis (LAMS) of gold-graphene composite is reported here. The material was characterized using transmission electron microscopy, field emission scanning electron microscopy, energy dispersive X-ray spectroscopy, powdered X-ray diffraction, Raman spectroscopy, Zeta potential measurements and UV-Visible spectroscopic techniques. The as-synthesized gold-graphene composite was effectively utilized as catalyst for decolorization of 4 important textile and laser dyes. The integration of gold nanoparticles (AuNPs) with high surface area graphene has enhanced the catalytic activity of AuNPs. This enhanced activity is attributed to the synergistic interplay of pristine gold's electronic relay and π-π stacking of graphene with the dyes. This is evident when the Rhodamine B (RB) reduction rate of the composite is nearly twice faster than that of commercial citrate capped AuNPs of similar size. In case of Methylene blue (MB) the rate of reduction is 17,000 times faster than uncatalyzed reaction. This synthetic method opens door to laser ablation based fabrication of metal catalysts on graphene for improved performance without the aid of linkers and surfactants.
NASA Astrophysics Data System (ADS)
Oelmann, J.; Gierse, N.; Li, C.; Brezinsek, S.; Zlobinski, M.; Turan, B.; Haas, S.; Linsmeier, Ch.
2018-06-01
Monitoring a sample's material composition became more and more important over the last years for both - industrial process control as well as for post mortem analysis in research and industrial development. Although material composition identification as well as a comparison with standard samples works fine, there is a lack of diagnostics which can provide quantitative information with depth resolution without any standard samples. We present a novel method utilizing a residual gas analysis with quadrupole mass spectrometry after picosecond laser-induced ablation and release of volatile species. In the present experiment, well characterized multilayer thin film solar cells (μc-Si:H and a-Si:D as p-i-n-junctions on ZnO:Al electrodes) are used as a set of well characterized material samples to demonstrate the capabilities of the new method. The linearity of the spectrometer signal to gas pressure simplifies its calibration and reduces its uncertainties in comparison with other analysis techniques, although high vacuum conditions (10-6 hPa to 10-7 hPa) are required to reach high sensitivity better than the percent-range. Moreover, the laser-ablation based sample analysis requires no preparation of the sample and is flexible regarding ablation rates. The application of a picosecond laser pulse ensures that the thermal penetration depth of the laser is in the same order of magnitude as the ablation rate, which enables to achieve depth resolutions in the order of 100 nm and avoids matrix mixing effects at the edge of the laser-induced crater in the sample.
Real-time airborne particle analyzer
Reilly, Peter T.A.
2012-10-16
An aerosol particle analyzer includes a laser ablation chamber, a gas-filled conduit, and a mass spectrometer. The laser ablation chamber can be operated at a low pressure, which can be from 0.1 mTorr to 30 mTorr. The ablated ions are transferred into a gas-filled conduit. The gas-filled conduit reduces the electrical charge and the speed of ablated ions as they collide and mix with buffer gases in the gas-filled conduit. Preferably, the gas filled-conduit includes an electromagnetic multipole structure that collimates the nascent ions into a beam, which is guided into the mass spectrometer. Because the gas-filled conduit allows storage of vast quantities of the ions from the ablated particles, the ions from a single ablated particle can be analyzed multiple times and by a variety of techniques to supply statistically meaningful analysis of composition and isotope ratios.
Effect of ZrO2 Powders on the Pyrolysis of Polycarbosilanes Coating Under Laser Ablation
NASA Astrophysics Data System (ADS)
Cheng, Han; Chen, Zhaofeng; Tao, Jie; Yan, Bo; Li, Cong; Wang, Liangbing; Zhang, Ying; Fang, Dan; Wan, Shuicheng; Wu, Wangping
Aircrafts hold the outstanding mastery of the sky in modern wars, however the laser beam weapons can carry out laser attacking to aircrafts. The purpose of the present paper is to research on a new type laser protective material. Polycarbosilanes (PCS)/divinylbenzene mixtures containing ZrO2 powders were brushed to the surface of the aluminum alloy plates and then cured at 150°C for 6 h. The PCS-coated plates were ablated by laser for 3 s. The phase identification of as-ablated powders was examined by X-ray diffraction. The results indicated that the as-ablated powders of cured PCS were composed of major phase β-SiC and smaller amounts of free carbon. The PCS composite coating played a certain role of laser ablation resistance. The effect of added ZrO2 powders on the pyrolysis of PCS-coating under laser ablation is conspicuous.
Paint stripping with a XeCl laser: basic research and processing techniques
NASA Astrophysics Data System (ADS)
Raiber, Armin; Plege, Burkhard; Holbein, Reinhold; Callies, Gert; Dausinger, Friedrich; Huegel, Helmut
1995-03-01
This work investigates the possibility of ablating paint from aerospace material with a XeCl- laser. The main advantage of this type of laser is the low heat generation during the ablation process. This is important when stripping thermally sensitive materials such as polymer composites. The dependence of the ablation process on energy density, pulse frequency as well as other laser parameters are presented. The results show the influence of chemical and UV artificial aging processes on ablation depth. Further, the behavior of the time-averaged transmission of the laser beam through the plasma is described as a function of the energy density. The time-varying temperature in the substrate at the point of ablation was measured during the process. An abrupt change in the temperature variation indicates the end of point ablation. This measured temperature variation is compared with the calculated temperatures, which are derived from the 1D heat equations. Finally, first results of repaintability and ablation rates will be presented.
Laboratory simulations of atmospheric entry of micrometeoroids: ablation of magnesium
NASA Astrophysics Data System (ADS)
Bones, David; Gomez Martin, Juan Carlos; Diego Carrillo Sanchez, Juan; Dobson, Alexander; Plane, John
2017-04-01
We address the uncertainty in the cosmic dust input into the Earth's atmosphere by simulating the atmospheric entry of micrometeoroids in a custom built chamber, capable of heating particles to 3000 K in 2 s and able to precisely reproduce representative heating profiles. In lieu of interplanetary cosmic dust, we use a range of ground-up recovered meteorites and mineral analogues. We measure the ablation of two metals simultaneously with laser induced fluorescence (LIF). The resulting ablation profiles can be compared with the composition of the remaining, unablated particle, as determined from scanning electron microscopy-energy dispersive x-ray (SEM-EDX) analysis. Building on earlier studies of Na, Fe and Ca, here we present Mg profiles and compare them with results from our chemical ablation model (CABMOD). In general, Mg behaves as predicted, beginning to ablate steadily as one broad ablation peak once temperatures reach 2000 K. In contrast Fe, which should behave similarly to Mg, typically has two ablation peaks due to being present in two distinct phases.
NASA Technical Reports Server (NTRS)
Winter, Michael
2012-01-01
The characterization of ablation and recession of heat shield materials during arc jet testing is an important step towards understanding the governing processes during these tests and therefore for a successful extrapolation of ground test data to flight. The behavior of ablative heat shield materials in a ground-based arc jet facility is usually monitored through measurement of temperature distributions (across the surface and in-depth), and through measurement of the final surface recession. These measurements are then used to calibrate/validate materials thermal response codes, which have mathematical models with reasonably good fidelity to the physics and chemistry of ablation, and codes thus calibrated are used for predicting material behavior in flight environments. However, these thermal measurements only indirectly characterize the pyrolysis processes within an ablative material pyrolysis is the main effect during ablation. Quantification of pyrolysis chemistry would therefore provide more definitive and useful data for validation of the material response codes. Information of the chemical products of ablation, to various levels of detail, can be obtained using optical methods. Suitable optical methods to measure the shape and composition of these layers (with emphasis on the blowing layer) during arc jet testing are: 1) optical emission spectroscopy (OES) 2) filtered imaging 3) laser induced fluorescence (LIF) and 4) absorption spectroscopy. Several attempts have been made to optically measure the material response of ablative materials during arc-jet testing. Most recently, NH and OH have been identified in the boundary layer of a PICA ablator. These species are suitable candidates for a detection through PLIF which would enable a spatially-resolved characterization of the blowing layer in terms of both its shape and composition. The recent emission spectroscopy data will be presented and future experiments for a qualitative and quantitative characterization of the material response of ablative materials during arc-jet testing will be discussed.
Cartilage ablation studies using mid-IR free electron laser
NASA Astrophysics Data System (ADS)
Youn, Jong-In; Peavy, George M.; Venugopalan, Vasan
2005-04-01
The ablation rate of articular cartilage and fibrocartilage (meniscus), were quantified to examine wavelength and tissue-composition dependence of ablation efficiency for selected mid-infrared wavelengths. The wavelengths tested were 2.9 um (water dominant absorption), 6.1 (protein and water absorption) and 6.45 um (protein dominant absorption) generated by the Free Electron Laser (FEL) at Vanderbilt University. The measurement of tissue mass removal using a microbalance during laser ablation was conducted to determine the ablation rates of cartilage. The technique can be accurate over methods such as profilometer and histology sectioning where tissue surface and the crater morphology may be affected by tissue processing. The ablation efficiency was found to be dependent upon the wavelength. Both articular cartilage and meniscus (fibrocartilage) ablations at 6.1 um were more efficient than those at the other wavelengths evaluated. We observed the lowest ablation efficiency of both types of cartilage with the 6.45 um wavelength, possibly due to the reduction in water absorption at this wavelength in comparison to the other wavelengths that were evaluated.
NASA Technical Reports Server (NTRS)
Patterson, W. J.
1979-01-01
A trowellable closeout/repair material designated as MTA-2 was developed and evaluated for use on the Solid Rocket Booster. This material is composed of an epoxy-polysulfide binder and is highly filled with phenolic microballoons for density control and ablative performance. Mechanical property testing and thermal testing were performed in a wind tunnel to simulate the combined Solid Rocket Booster trajectory aeroshear and heating environments. The material is characterized by excellent thermal performance and was used extensively on the Space Shuttle STS-1 and STS-2 flight hardware.
3D Multifunctional Ablative Thermal Protection System
NASA Technical Reports Server (NTRS)
Feldman, Jay; Venkatapathy, Ethiraj; Wilkinson, Curt; Mercer, Ken
2015-01-01
NASA is developing the Orion spacecraft to carry astronauts farther into the solar system than ever before, with human exploration of Mars as its ultimate goal. One of the technologies required to enable this advanced, Apollo-shaped capsule is a 3-dimensional quartz fiber composite for the vehicle's compression pad. During its mission, the compression pad serves first as a structural component and later as an ablative heat shield, partially consumed on Earth re-entry. This presentation will summarize the development of a new 3D quartz cyanate ester composite material, 3-Dimensional Multifunctional Ablative Thermal Protection System (3D-MAT), designed to meet the mission requirements for the Orion compression pad. Manufacturing development, aerothermal (arc-jet) testing, structural performance, and the overall status of material development for the 2018 EM-1 flight test will be discussed.
Hong, Chae Moon; Lee, Won Kee; Jeong, Shin Young; Lee, Sang-Woo; Ahn, Byeong-Cheol; Lee, Jaetae
2014-11-01
The aim of this study was to validate the effectiveness of delayed risk stratification (DRS) in predicting structural progression and compare the predictive value of American Thyroid Association (ATA) risk stratification with that of DRS in patients with differentiated thyroid cancer (DTC). A total of 398 patients with DTC who underwent surgery followed by radioactive iodine ablation were enrolled. Patients were categorized as having excellent response, acceptable response, biochemical incomplete response, or structural incomplete response at 8-15 months' evaluation after radioactive iodine ablation for DRS. Effectiveness of DRS was evaluated according to structural progression-free survival (PFS; median follow-up, 10.7 years). A total of 229 patients (57.5%) were classified as having excellent response, 78 (19.6%) as having acceptable response, 62 (15.6%) as having biochemical incomplete response, and 29 patients (7.3%) as having structural incomplete response. After DRS, 60.2% of intermediate-risk patients and 20.5% of high-risk patients were shifted to the excellent response category. Sixty-nine patients (17.3%) showed structural progression. DRS showed statistical difference in PFS (hazard ratio, 4.268; 95% confidence interval, 3.258-5.477; P<0.001). In multivariate analysis of ATA risk stratification and DRS, DRS was significantly associated with PFS (hazard ratio, 4.383; 95% confidence interval, 3.250-5.912; P<0.001), but ATA risk stratification was not. There was no significant difference in deviances between the use of DRS alone and the use of both DRS and ATA risk stratification (χ=0.103, d.f.=1, P=0.748). DRS is superior to ATA risk stratification in predicting structural disease progression for DTC patients.
Porter, Michael; Spear, William; Akar, Joseph G; Helms, Ray; Brysiewicz, Neil; Santucci, Peter; Wilber, David J
2008-06-01
Complex fractionated atrial electrograms (CFAE) may identify critical sites for perpetuation of atrial fibrillation (AF) and provide useful targets for ablation. Current assessment of CFAE is subjective; automated detection algorithms may improve reproducibility, but their utility in guiding ablation has not been tested. In 67 patients presenting for initial AF ablation (42 paroxysmal, 25 persistent), LA and CS mapping were performed during induced or spontaneous AF. CFAE were identified by an online automated computer algorithm and displayed on electroanatomical maps. A mean of 28 +/- 18 sites/patient were identified (20 +/- 13% of mapped sites), and were more frequent during persistent AF. CFAE occurred most commonly within the CS, on the atrial septum, and around the pulmonary veins. Ablation initially targeting CFAE terminated AF in 88% of paroxysmal AF, but only 20% of persistent AF (P < 0.001). Subsequently, additional ablation was performed in all patients (PV isolation for paroxysmal AF, PV isolation + mitral and roof lines for persistent AF). Minimum follow-up was 1 year. One-year freedom from recurrent atrial arrhythmias without antiarrhythmic drug therapy after a single procedure was 90% for paroxysmal AF, and 68% for persistent AF. Ablation guided by automated detection of CFAE proved feasible, and was associated with a high AF termination rate in paroxysmal, but not persistent AF. As an adjunct to conventional techniques, it was associated with excellent long-term single procedure outcomes in both groups. Criteria for identifying optimal CFAE sites for ablation, and selection of patients most likely to benefit, require additional study.
Femtosecond laser ablation of bovine cortical bone
NASA Astrophysics Data System (ADS)
Cangueiro, Liliana T.; Vilar, Rui; Botelho do Rego, Ana M.; Muralha, Vania S. F.
2012-12-01
We study the surface topographical, structural, and compositional modifications induced in bovine cortical bone by femtosecond laser ablation. The tests are performed in air, with a Yb:KYW chirped-pulse-regenerative amplification laser system (500 fs, 1030 nm) at fluences ranging from 0.55 to 2.24 J/cm2. The ablation process is monitored by acoustic emission measurements. The topography of the laser-treated surfaces is studied by scanning electron microscopy, and their constitution is characterized by glancing incidence x-ray diffraction, x-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy, and micro-Raman spectroscopy. The results show that femtosecond laser ablation allows removing bone without melting, carbonization, or cracking. The structure and composition of the remaining tissue are essentially preserved, the only constitutional changes observed being a reduction of the organic material content and a partial recrystallization of hydroxyapatite in the most superficial region of samples. The results suggest that, within this fluence range, ablation occurs by a combination of thermal and electrostatic mechanisms, with the first type of mechanism predominating at lower fluences. The associated thermal effects explain the constitutional changes observed. We show that femtosecond lasers are a promising tool for delicate orthopaedic surgeries, where small amounts of bone must be cut with negligible damage, thus minimizing surgical trauma.
Zhou, Min; Zhang, Rui; Huang, Miao; Lu, Wei; Song, Shaoli; Melancon, Marites P.; Tian, Mei; Liang, Dong; Li, Chun
2010-01-01
We synthesized and evaluated a novel class of chelator-free [64Cu]-CuS nanoparticles (NPs) suitable for both PET imaging and as photothermal coupling agents for photothermal ablation. [64Cu]-CuS NPs were simple to make, possessed excellent stability, and allowed robust noninvasive micro-PET imaging. Furthermore, CuS NPs displayed strong absorption in the near-infrared (NIR) region (peak 930 nm), passive targeting prefers the tumor site, and mediated ablation of U87 tumor cells upon exposure to NIR light both in vitro and in vivo after either intratumoral or intravenous injection. The combination of small diameter (~11 nm diameter), strong NIR absorption, and integration of 64Cu as a structural component makes [64Cu]-CuS NPs ideally suited for multifunctional molecular imaging and therapy. PMID:20942456
[Percutaneous lung thermo-ablation].
Palussière, Jean; Catena, Vittorio; Gaubert, Jean-Yves; Buy, Xavier; de Baere, Thierry
2017-05-01
Percutaneous lung thermo-ablation has steadily been developed over the past 15years. Main indications are early stage non-small cell lung carcinoma (NSCLC) for non-surgical patients and slow evolving localized metastatic disease, either spontaneous or following a general treatment. Radiofrequency, being the most evaluated technique, offers a local control rate of about 80-90% for tumors <3 cm in diameter. With excellent tolerance and very few complications, radiofrequency may be proposed for patients with a chronic disease. Other ablation techniques under investigation such as microwaves and cryotherapy could allow overcoming radiofrequency limits. Furthermore, stereotactic radiotherapy proposed for the same indications is efficient. Comparative studies are warranted to differentiate these techniques in terms of efficacy, tolerance and cost-effectiveness. Copyright © 2017 Société Française du Cancer. Published by Elsevier Masson SAS. All rights reserved.
Intumescent-ablator coatings using endothermic fillers
NASA Technical Reports Server (NTRS)
Sawko, P. M.; Riccitiello, S. R. (Inventor)
1978-01-01
An intumescent-ablator coating composition which contains the ammonium salt of 1,4-nitroaniline-2-sulfonic acid or 4,4 dinitrosul fanilide, a polymeric binder system and about 5 to 30% weight of an endothermic filler is reported. The filler has a decomposition temperature about or within the exothermic region of the intumescent agent.
Surface Modification of Carbon Fiber Polymer Composites after Laser Structuring
NASA Astrophysics Data System (ADS)
Sabau, Adrian S.; Chen, Jian; Jones, Jonaaron F.; Hackett, Alexandra; Jellison, Gerald D.; Daniel, Claus; Warren, David; Rehkopf, Jackie D.
The increasing use of Carbon Fiber-reinforced Polymer matrix Composites (CFPC) as a lightweight material in automotive and aerospace industries requires the control of surface morphology. In this study, the composites surface was prepared by ablating the resin on the top fiber layer of the composite using an Nd:YAG laser. The CFPC specimens with T700S carbon fiber and Prepreg — T83 resin (epoxy) were supplied by Plasan Carbon Composites, Inc. as 4 ply thick, 0/90° plaques. The effect of laser fluence, scanning speed, and wavelength was investigated on the removal rate of the resin without an excessive damage of the fibers. In addition, resin ablation due to the power variation created by a laser interference technique is presented. Optical property measurements, optical micrographs, 3D imaging, and high-resolution optical profiler images were used to study the effect of the laser processing on surface morphology.
NASA Astrophysics Data System (ADS)
Ait Oumeziane, Amina; Parisse, Jean-Denis
2018-05-01
Titanium carbide (TiC) coatings of great quality can be produced using nanosecond pulsed laser deposition (PLD). Because the deposition rate and the transfer of the target stoichiometry depend strongly on the laser-target/laser-plasma interaction as well as the composition of the laser induced plume, investigating the ruling fundamental mechanisms behind the material ablation and the plasma evolution in the background environment under PLD conditions is essential. This work, which extends previous investigations dedicated to the study of nanosecond laser ablation of pure target materials, is a first step toward a comprehensive non-equilibrium model of multicomponent ones. A laser-material interaction model coupled to a laser-plasma interaction one is presented. A UV 20 ns KrF (248 nm) laser pulse is considered. Ablation depths, plasma ignition thresholds, and shielding rates have been calculated for a wide range of laser beam fluences. A comparison of TiC behavior with pure titanium material under the same conditions is made. Plasma characteristics such as temperature and composition have been investigated. An overall correlation between the various results is presented.
Long-term outcomes of remote magnetic navigation for ablation of supraventricular tachycardias.
Kim, Sung-Hwan; Oh, Yong-Seog; Kim, Dong-Hwi; Choi, Ik Jun; Kim, Tae-Seok; Shin, Woo-Seung; Kim, Ji-Hoon; Jang, Sung-Won; Lee, Man Young; Rho, Tai-Ho
2015-08-01
Little is known about the long-term outcomes of catheter ablation of supraventricular tachycardia (SVT) using remote magnetic navigation system (RMN). One hundred twenty patients underwent catheter ablation of SVTs with RMN (Niobe, Stereotaxis, USA): atrioventricular nodal re-entrant tachycardia (AVNRT; n = 59), atrioventricular re-entrant tachycardia (AVRT; n = 45), and focal atrial tachycardia (AT, n = 16). The outcome of AVRT with right free wall accessory pathway was compared with those of a group of 26 consecutive patients undergoing manual ablation. Mean follow-up period was 2.2 ± 1.4 years. Overall arrhythmia-free survival was 86%; AVRT (77%), AVNRT (96%), and focal AT (71%). After the learning period (initial 50 cases), procedural outcomes had improved for AVRT and AVNRT (91% in overall group, 90% in AVRT group, 100% in AVNRT group, and 68% in focal AT group). The recurrence-free rate was higher for the free wall accessory pathways than those of the other sites (92 vs. 73%, log-rank P = 0.06). Furthermore, when it is confined for the right free wall accessory pathway, RMN showed excellent long-term outcome (7/7, 100 %) compared to the results of manual approach (18/26, 69.2%, log-rank P = 0.07). RMN showed favorable long-term outcomes for the ablation of SVT. In our experience, RMN-guided ablation may be associated with a higher success rate as compared to manual ablation when treating right-sided free wall pathways.
Numerical-experimental analysis of a carbon-phenolic composite via plasma jet ablation test
NASA Astrophysics Data System (ADS)
Guilherme Silva Pesci, Pedro; Araújo Machado, Humberto; Silva, Homero de Paula e.; Cley Paterniani Rita, Cristian; Petraconi Filho, Gilberto; Cocchieri Botelho, Edson
2018-06-01
Materials used in space vehicles components are subjected to thermally aggressive environments when exposed to atmospheric reentry. In order to protect the payload and the vehicle itself, ablative composites are employed as TPS (Thermal Protection System). The development of TPS materials generally go through phases of obtaining, atmospheric reentry tests and comparison with a mathematical model. The state of the art presents some reentry tests in a subsonic or supersonic arc-jet facility, and a complex type of mathematical model, which normally requires large computational cost. This work presents a reliable method for estimate the performance of ablative composites, combining empirical and experimental data. Tests of composite materials used in thermal protection systems through exposure to a plasma jet are performed, where the heat fluxes emulate those present in atmospheric reentry of space vehicles components. The carbon/phenolic material samples have been performed in the hypersonic plasma tunnel of Plasma and Process Laboratory, available in Aeronautics Institute of Technology (ITA), by a plasma torch with a 50 kW DC power source. The plasma tunnel parameters were optimized to reproduce the conditions close to the critical re-entry point of the space vehicles payloads developed by the Aeronautics and Space Institute (IAE). The specimens in study were developed and manufactured in Brazil. Mass loss and specific mass loss rates of the samples and the back surface temperatures, as a function of the exposure time to the thermal flow, were determined. A computational simulation based in a two-front ablation model was performed, in order to compare the tests and the simulation results. The results allowed to estimate the ablative behavior of the tested material and to validate the theoretical model used in the computational simulation for its use in geometries close to the thermal protection systems used in the Brazilian space and suborbital vehicles.
Selective removal of dental composite using a rapidly scanned carbon dioxide laser
NASA Astrophysics Data System (ADS)
Chan, Kenneth H.; Fried, Daniel
2011-03-01
Dental restorative materials are color matched to the tooth and are difficult to remove by mechanical means without excessive removal or damage to peripheral enamel and dentin. Lasers are ideally suited for selective ablation to minimize healthy tissue loss when replacing existing restorations, sealants or removing composite adhesives such as residual composite left after debonding orthodontic brackets. In this study a carbon dioxide laser operating at high laser pulse repetition rates integrated with a galvanometer based scanner was used to selectively remove composite from tooth surfaces. A diode array spectrometer was used to measure the plume emission after each laser pulse and determine if the ablated material was tooth mineral or composite. The composite was placed on tooth buccal and occlusal surfaces and the carbon dioxide laser was scanned across the surface to selectively remove the composite without excessive damage to the underlying sound enamel. The residual composite and the damage to the underlying enamel was evaluated using optical microscopy. The laser was able to rapidly remove the composites rapidly from both surfaces with minimal damage to the underlying sound enamel.
Burke, Caitlin W.; Price, Richard J.
2010-01-01
We are developing minimally-invasive contrast agent microbubble based therapeutic approaches in which the permeabilization and/or ablation of the microvasculature are controlled by varying ultrasound pulsing parameters. Specifically, we are testing whether such approaches may be used to treat malignant brain tumors through drug delivery and microvascular ablation. Preliminary studies have been performed to determine whether targeted drug-bearing nanoparticle delivery can be facilitated by the ultrasound mediated destruction of "composite" delivery agents comprised of 100nm poly(lactide-co-glycolide) (PLAGA) nanoparticles that are adhered to albumin shelled microbubbles. We denote these agents as microbubble-nanoparticle composite agents (MNCAs). When targeted to subcutaneous C6 gliomas with ultrasound, we observed an immediate 4.6-fold increase in nanoparticle delivery in MNCA treated tumors over tumors treated with microbubbles co-administered with nanoparticles and a 8.5 fold increase over non-treated tumors. Furthermore, in many cancer applications, we believe it may be desirable to perform targeted drug delivery in conjunction with ablation of the tumor microcirculation, which will lead to tumor hypoxia and apoptosis. To this end, we have tested the efficacy of non-theramal cavitation-induced microvascular ablation, showing that this approach elicits tumor perfusion reduction, apoptosis, significant growth inhibition, and necrosis. Taken together, these results indicate that our ultrasound-targeted approach has the potential to increase therapeutic efficiency by creating tumor necrosis through microvascular ablation and/or simultaneously enhancing the drug payload in gliomas. PMID:21206463
Burke, Caitlin W; Price, Richard J
2010-12-15
We are developing minimally-invasive contrast agent microbubble based therapeutic approaches in which the permeabilization and/or ablation of the microvasculature are controlled by varying ultrasound pulsing parameters. Specifically, we are testing whether such approaches may be used to treat malignant brain tumors through drug delivery and microvascular ablation. Preliminary studies have been performed to determine whether targeted drug-bearing nanoparticle delivery can be facilitated by the ultrasound mediated destruction of "composite" delivery agents comprised of 100nm poly(lactide-co-glycolide) (PLAGA) nanoparticles that are adhered to albumin shelled microbubbles. We denote these agents as microbubble-nanoparticle composite agents (MNCAs). When targeted to subcutaneous C6 gliomas with ultrasound, we observed an immediate 4.6-fold increase in nanoparticle delivery in MNCA treated tumors over tumors treated with microbubbles co-administered with nanoparticles and a 8.5 fold increase over non-treated tumors. Furthermore, in many cancer applications, we believe it may be desirable to perform targeted drug delivery in conjunction with ablation of the tumor microcirculation, which will lead to tumor hypoxia and apoptosis. To this end, we have tested the efficacy of non-theramal cavitation-induced microvascular ablation, showing that this approach elicits tumor perfusion reduction, apoptosis, significant growth inhibition, and necrosis. Taken together, these results indicate that our ultrasound-targeted approach has the potential to increase therapeutic efficiency by creating tumor necrosis through microvascular ablation and/or simultaneously enhancing the drug payload in gliomas.
Reentry Thermal Analysis of a Generic Crew Exploration Vehicle Structure
NASA Technical Reports Server (NTRS)
Ko, William L.; Gong, Leslie; Quinn, Robert D.
2007-01-01
Comparative studies were performed on the heat-shielding characteristics of honeycomb-core sandwich panels fabricated with different materials for possible use as wall panels for the proposed crew exploration vehicle. Graphite/epoxy sandwich panel was found to outperform aluminum sandwich panel under the same geometry due to superior heat-shielding qualities and lower material density. Also, representative reentry heat-transfer analysis was performed on the windward wall structures of a generic crew exploration vehicle. The Apollo low Earth orbit reentry trajectory was used to calculate the reentry heating rates. The generic crew exploration vehicle has a graphite/epoxy composite honeycomb sandwich exterior wall and an aluminum honeycomb sandwich interior wall, and is protected with the Apollo thermal protection system ablative material. In the thermal analysis computer program used, the TPS ablation effect was not yet included; however, the results from the nonablation heat-transfer analyses were used to develop a "virtual ablation" method to estimate the ablation heat loads and the thermal protection system recession thicknesses. Depending on the severity of the heating-rate time history, the virtual ablation period was found to last for 87 to 107 seconds and the ablation heat load was estimated to be in the range of 86 to 88 percent of the total heat load for the ablation time period. The thermal protection system recession thickness was estimated to be in the range of 0.08 to 0.11 inches. For the crew exploration vehicle zero-tilt and 18-degree-tilt stagnation points, thermal protection system thicknesses of h = {0.717, 0.733} inches were found to be adequate to keep the substructural composite sandwich temperature below the limit of 300 F.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabau, Adrian S; Chen, Jian; Jones, Jonaaron F.
The increasing use of Carbon Fiber Polymer Composite (CFPC) as a lightweight material in automotive and aerospace industries requires the control of surface morphology. In this study, the composites surface was prepared by ablating the resin in the top fiber layer of the composite using an Nd:YAG laser. The CFPC specimens with T700S carbon fiber and Prepreg - T83 resin (epoxy) were supplied by Plasan Carbon Composites, Inc. as 4 ply thick, 0/90o plaques. The effect of laser fluence, scanning speed, and wavelength was investigated to remove resin without an excessive damage of the fibers. In addition, resin ablation duemore » to the power variation created by a laser interference technique is presented. Optical property measurements, optical micrographs, 3D imaging, and high-resolution optical profiler images were used to study the effect of the laser processing on the surface morphology.« less
Ablation by-products of dental materials from the Er:YAG laser and the dental handpiece
NASA Astrophysics Data System (ADS)
Wigdor, Harvey A.; Visuri, Steven R.; Walsh, Joseph T., Jr.
1995-05-01
Recently there has been much interest in lasers and their potential use to replace the dental drill. The research has been directed towards vital dental tissues. It must be understood that any laser to be used in dentistry which will replace the dental drill must also ablate and remove existing dental materials. Some concern exists about the ablation products when the Er:YAG laser is used to ablate dental materials. It is incumbent on the professionals using these lasers to understand the materials being produced by these lasers and protect themselves and their patients from possible toxic products. It is the intent of this paper to evaluate the products produced by the ablation of both dental amalgam and composite dental restorative materials and compare them with those produced by the traditional dental handpiece (drill).
Laser ablation in analytical chemistry - A review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Russo, Richard E.; Mao, Xianglei; Liu, Haichen
Laser ablation is becoming a dominant technology for direct solid sampling in analytical chemistry. Laser ablation refers to the process in which an intense burst of energy delivered by a short laser pulse is used to sample (remove a portion of) a material. The advantages of laser ablation chemical analysis include direct characterization of solids, no chemical procedures for dissolution, reduced risk of contamination or sample loss, analysis of very small samples not separable for solution analysis, and determination of spatial distributions of elemental composition. This review describes recent research to understand and utilize laser ablation for direct solid sampling,more » with emphasis on sample introduction to an inductively coupled plasma (ICP). Current research related to contemporary experimental systems, calibration and optimization, and fractionation is discussed, with a summary of applications in several areas.« less
Spectroscopy Measurements on Ablation Testing in High Enthalpy Plasma Flows
2010-11-01
sample as well as the recession rate. Further, the chemical composition of the free- stream and the surrounding gas layer in front of the sample...of the samples due to ablation (mass loss & surface recession ), different temperature measurements (surface & inside) and spectroscopic results...25 5 MEASUREMENT RESULTS AND DISCUSSIONS ................................................................ 26 5.1 MASS LOSS AND RECESSION
Development of aerogel-lined targets for inertial confinement fusion experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Braun, Tom
2013-03-28
This thesis explores the formation of ICF compatible foam layers inside of an ablator shell used for inertial confinement fusion experiments at the National Ignition Facility. In particular, the capability of p- DCPD polymer aerogels to serve as a scaffold for the deuterium-tritium mix was analyzed. Four different factors were evaluated: the dependency of different factors such as thickness or composition of a precursor solution on the uniformity of the aerogel layer, how to bring the optimal composition inside of the ablator shell, the mechanical stability of ultra-low density p-DCPD aerogel bulk pieces during wetting and freezing with hydrogen, andmore » the wetting behavior of thin polymer foam layers in HDC carbon ablator shells with liquid deuterium. The research for thesis was done at Lawrence Livermore National Laboratory in cooperation with the Technical University Munich.« less
Mehari, Fanuel; Rohde, Maximillian; Kanawade, Rajesh; Knipfer, Christian; Adler, Werner; Klämpfl, Florian; Stelzle, Florian; Schmidt, Michael
2016-10-01
In the present study, the elemental compositions of fat and nerve tissue during their plasma mediated laser ablation are studied in the context of tissue differentiation for laser surgery applications by using Laser-Induced Breakdown Spectroscopy (LIBS). Tissue samples of porcine fat and nerve were prepared as ex vivo experimental objects. Plasma mediated laser ablation is performed using an Nd : YAG laser in open air and under normal stray light conditions. The performed measurements suggest that the two tissue types show a high similarity in terms of qualitative elemental composition while at the same time revealing a distinct difference in the concentration of the constituent elements. Different analysis approaches are evaluated and discussed to optimize the tissue-differentiation performance of the LIBS approach. Plasma mediated laser tissue ablation. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borodina, T I; Val'yano, G E; Gololobova, O A
2014-09-30
Absorption, fluorescence and Raman spectra, the structural composition and morphology of zirconia nanoparticles synthesised via the laser ablation of a metal in water and aqueous solutions of the sodium dodecyl sulphate (SDS) surfactant have been studied using absorption spectroscopy, Raman spectroscopy, X-ray diffraction and scanning electron microscopy. The results demonstrate that, exposing zirconium to intense nanosecond laser pulses at a high repetition rate in these liquids, one can obtain stable cubic, tetragonal and monoclinic crystalline phases of nanozirconia with a particle size in the range 40 – 100 nm and a Zr – SDS organic – inorganic composite. The absorptionmore » and fluorescence of the synthesised zirconia strongly depend on the SDS concentration in the starting solution. The gas – vapour bubbles forming during ablation are shown to serve as templates for the formation of hollow nanoand microstructures. (nanostructures)« less
Sung, Tae-Yon; Cho, Jae Won; Lee, Yu-Mi; Lee, Yi Ho; Kwon, Hyemi; Jeon, Min Ji; Kim, Won Gu; Choi, Young Jun; Song, Dong Eun; Chung, Ki-Wook; Yoon, Jong Ho; Hong, Suck Joon
2017-11-01
This study validated the dynamic risk stratification (DRS) system with regard to its association with structural recurrence and risk factors associated with non-excellent responses in patients <45 years with stage I classical papillary thyroid cancer (PTC). This historical cohort study included 598 patients with stage I classical PTC <45 years of age treated with total thyroidectomy followed by radioactive iodine remnant ablation (n = 440), total thyroidectomy without radioactive iodine remnant ablation (n = 23), and thyroid lobectomy alone (n = 135). The median follow-up period was 123 months. Structural recurrence occurred in 4.2% (n = 18/432) of the patients with an excellent response, 17.1% (18/105) of patients with an indeterminate response, 44.7% (17/38) of patients with a biochemically incomplete response, and 82.6% (19/23) of patients with a structurally incomplete response (p < 0.001) during the follow-up. The disease-free survival curves of each response showed significant differences (p < 0.001). Extensive extrathyroidal extension and extranodal extension were the independent risk factors associated with non-excellent response (p < 0.05). DRS may reduce unnecessary additional treatments by reclassifying initial risk estimates of structural recurrence. Furthermore, applying the risk factors associated with non-excellent response to initial therapy may be a more useful and viable surrogate of the risk for structural recurrence in stage I PTC patients <45 years of age.
Kim, Young-sun; Lim, Hyo Keun; Park, Min Jung; Rhim, Hyunchul; Jung, Sin-Ho; Sohn, Insuk; Kim, Tae-Joong; Keserci, Bilgin
2016-01-01
The aim of this study was to fit and validate screening magnetic resonance imaging (MRI)-based prediction models for assessing immediate therapeutic responses of uterine fibroids to MRI-guided high-intensity focused ultrasound (MR-HIFU) ablation. Informed consent from all subjects was obtained for our institutional review board-approved study. A total of 240 symptomatic uterine fibroids (mean diameter, 6.9 cm) in 152 women (mean age, 43.3 years) treated with MR-HIFU ablation were retrospectively analyzed (160 fibroids for training, 80 fibroids for validation). Screening MRI parameters (subcutaneous fat thickness [mm], x1; relative peak enhancement [%] in semiquantitative perfusion MRI, x2; T2 signal intensity ratio of fibroid to skeletal muscle, x3) were used to fit prediction models with regard to ablation efficiency (nonperfused volume/treatment cell volume, y1) and ablation quality (grade 1-5, poor to excellent, y2), respectively, using the generalized estimating equation method. Cutoff values for achievement of treatment intent (efficiency >1.0; quality grade 4/5) were determined based on receiver operating characteristic curve analysis. Prediction performances were validated by calculating positive and negative predictive values. Generalized estimating equation analyses yielded models of y1 = 2.2637 - 0.0415x1 - 0.0011x2 - 0.0772x3 and y2 = 6.8148 - 0.1070x1 - 0.0050x2 - 0.2163x3. Cutoff values were 1.312 for ablation efficiency (area under the curve, 0.7236; sensitivity, 0.6882; specificity, 0.6866) and 4.019 for ablation quality (0.8794; 0.7156; 0.9020). Positive and negative predictive values were 0.917 and 0.500 for ablation efficiency and 0.978 and 0.600 for ablation quality, respectively. Screening MRI-based prediction models for assessing immediate therapeutic responses of uterine fibroids to MR-HIFU ablation were fitted and validated, which may reduce the risk of unsuccessful treatment.
Yoon, Jeonghoon; Cho, Jeiwon; Kim, Namgon; Kim, Dae-Duk; Lee, Eunsook; Cheon, Changyul; Kwon, Youngwoo
2011-10-15
To overcome the limits of conventional microwave ablation, a new frequency spectrum above 6 GHz has been explored for low-power and low collateral damage ablation procedure. A planar coaxial probe-based applicator, suitable for easy insertion into the human body, was developed for our study to cover a wideband frequency up to 30 GHz. Thermal ablations with small input power (1-3 W) at various microwave frequencies were performed on nude mice xenografted with human breast cancer. Comparative study of ablation efficiencies revealed that 18-GHz microwave results in the largest difference in the temperature rise between cancer and normal tissues as well as the highest ablation efficiency, reaching 20 times that of 2 GHz. Thermal profile study on the composite region of cancer and fat also showed significantly reduced collateral damage using 18 GHz. Application of low-power (1 W) 18-GHz microwave on the nude mice xenografted with human breast cancer cells resulted in recurrence-free treatment. The proposed microwave ablation method can be a very effective process to treat small-sized tumor with minimized invasiveness and collateral damages. Copyright © 2010 UICC.
Femtosecond laser ablation and nanoparticle formation in intermetallic NiAl
NASA Astrophysics Data System (ADS)
Jorgensen, David J.; Titus, Michael S.; Pollock, Tresa M.
2015-10-01
The ablation behavior of a stoichiometric intermetallic compound β-NiAl subjected to femtosecond laser pulsing in air has been investigated. The single-pulse ablation threshold for NiAl was determined to be 83 ± 4 mJ/cm2 and the transition to the high-fluence ablation regime occurred at 2.8 ± 0.3 J/cm2. Two sizes of nanoparticles consisting of Al, NiAl, Ni3Al and NiO were formed and ejected from the target during high-fluence ablation. Chemical analysis revealed that smaller nanoparticles (1-30 nm) tended to be rich in Al while larger nanoparticles (>100 nm) were lean in Al. Ablation in the low-fluence regime maintained this trend. Redeposited material and nanoparticles remaining on the surface after a single 3.7 J/cm2 pulse, one hundred 1.7 J/cm2 pulses, or one thousand 250 mJ/cm2 pulses were enriched in Al relative to the bulk target composition. Further, the surface of the irradiated high-fluence region was depleted in Al indicating that the fs laser ablation removal rate of the intermetallic constituents in this regime does not scale with the individual pure element ablation thresholds.
Visual Outcomes After LASIK Using Topography-Guided vs Wavefront-Guided Customized Ablation Systems.
Toda, Ikuko; Ide, Takeshi; Fukumoto, Teruki; Tsubota, Kazuo
2016-11-01
To evaluate the visual performance of two customized ablation systems (wavefront-guided ablation and topography-guided ablation) in LASIK. In this prospective, randomized clinical study, 68 eyes of 35 patients undergoing LASIK were enrolled. Patients were randomly assigned to wavefront-guided ablation using the iDesign aberrometer and STAR S4 IR Excimer Laser system (Abbott Medical Optics, Inc., Santa Ana, CA) (wavefront-guided group; 32 eyes of 16 patients; age: 29.0 ± 7.3 years) or topography-guided ablation using the OPD-Scan aberrometer and EC-5000 CXII excimer laser system (NIDEK, Tokyo, Japan) (topography-guided group; 36 eyes of 19 patients; age: 36.1 ± 9.6 years). Preoperative manifest refraction was -4.92 ± 1.95 diopters (D) in the wavefront-guided group and -4.44 ± 1.98 D in the topography-guided group. Visual function and subjective symptoms were compared between groups before and 1 and 3 months after LASIK. Of seven subjective symptoms evaluated, four were significantly milder in the wavefront-guided group at 3 months. Contrast sensitivity with glare off at low spatial frequencies (6.3° and 4°) was significantly higher in the wavefront-guided group. Uncorrected and corrected distance visual acuity, manifest refraction, and higher order aberrations measured by OPD-Scan and iDesign were not significantly different between the two groups at 1 and 3 months after LASIK. Both customized ablation systems used in LASIK achieved excellent results in predictability and visual function. The wavefront-guided ablation system may have some advantages in the quality of vision. It may be important to select the appropriate system depending on eye conditions such as the pattern of total and corneal higher order aberrations. [J Refract Surg. 2016;32(11):727-732.]. Copyright 2016, SLACK Incorporated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, A. K., E-mail: adavi@lle.rochester.edu; Cao, D.; Michel, D. T.
The angularly resolved mass ablation rates and ablation-front trajectories for Si-coated CH targets were measured in direct-drive inertial confinement fusion experiments to quantify cross-beam energy transfer (CBET) while constraining the hydrodynamic coupling. A polar-direct-drive laser configuration, where the equatorial laser beams were dropped and the polar beams were repointed from a symmetric direct-drive configuration, was used to limit CBET at the pole while allowing it to persist at the equator. The combination of low- and high-CBET conditions observed in the same implosion allowed for the effects of CBET on the ablation rate and ablation pressure to be determined. Hydrodynamic simulationsmore » performed without CBET agreed with the measured ablation rate and ablation-front trajectory at the pole of the target, confirming that the CBET effects on the pole are small. The simulated mass ablation rates and ablation-front trajectories were in excellent agreement with the measurements at all angles when a CBET model based on Randall's equations [C. J. Randall et al., Phys. Fluids 24, 1474 (1981)] was included into the simulations with a multiplier on the CBET gain factor. These measurements were performed on OMEGA and at the National Ignition Facility to access a wide range of plasma conditions, laser intensities, and laser beam geometries. The presence of the CBET gain multiplier required to match the data in all of the configurations tested suggests that additional physics effects, such as intensity variations caused by diffraction, polarization effects, or shortcomings of extending the 1-D Randall model to 3-D, should be explored to explain the differences in observed and predicted drive.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, A. K.; Cao, D.; Michel, D. T.
The angularly-resolved mass ablation rates and ablation front trajectories for Si-coated CH targets were measured in direct-drive inertial confinement fusion experiments to quantify crossbeam energy transfer (CBET) while constraining the hydrodynamic coupling. A polar-direct-drive laser configuration was used, where the equatorial laser beams were dropped from a symmetric direct-drive configuration to suppress CBET at the pole, while allowing it to persist at the equator. The combination of low- and high-CBET conditions in the same implosion allowed the effects of CBET on the ablation rate and ablation pressure to be decoupled from the other physics effects that influence laser-coupling. Hydrodynamic simulationsmore » performed without CBET reproduced the measured ablation rate and ablation front trajectory at the pole of the target, verifying that the other laser-coupling physics effects are well-modeled when CBET effects are negligible. The simulated mass ablation rates and ablation front trajectories were in excellent agreement with the measurements at all angles when a CBET model based on Randall’s equations [C. J. Randall et al., Phys. Fluids 24, 1474 (1981)] was included into the simulations with an optimized multiplier on the CBET gain factor. These measurements were performed on both OMEGA and the National Ignition Facility to access a wide range of plasma conditions, laser intensities, and laser beam geometries. Furthermore, the presence of the CBET gain multiplier required to match the data in all of the configurations tested suggests that additional physics effects, such as intensity variations due to diffraction, shortcomings of extending the 1-D Randall model to 3-D, or polarization effects, should be explored to explain the differences in observed and predicted drive.« less
Davis, A. K.; Cao, D.; Michel, D. T.; ...
2016-04-20
The angularly-resolved mass ablation rates and ablation front trajectories for Si-coated CH targets were measured in direct-drive inertial confinement fusion experiments to quantify crossbeam energy transfer (CBET) while constraining the hydrodynamic coupling. A polar-direct-drive laser configuration was used, where the equatorial laser beams were dropped from a symmetric direct-drive configuration to suppress CBET at the pole, while allowing it to persist at the equator. The combination of low- and high-CBET conditions in the same implosion allowed the effects of CBET on the ablation rate and ablation pressure to be decoupled from the other physics effects that influence laser-coupling. Hydrodynamic simulationsmore » performed without CBET reproduced the measured ablation rate and ablation front trajectory at the pole of the target, verifying that the other laser-coupling physics effects are well-modeled when CBET effects are negligible. The simulated mass ablation rates and ablation front trajectories were in excellent agreement with the measurements at all angles when a CBET model based on Randall’s equations [C. J. Randall et al., Phys. Fluids 24, 1474 (1981)] was included into the simulations with an optimized multiplier on the CBET gain factor. These measurements were performed on both OMEGA and the National Ignition Facility to access a wide range of plasma conditions, laser intensities, and laser beam geometries. Furthermore, the presence of the CBET gain multiplier required to match the data in all of the configurations tested suggests that additional physics effects, such as intensity variations due to diffraction, shortcomings of extending the 1-D Randall model to 3-D, or polarization effects, should be explored to explain the differences in observed and predicted drive.« less
Koh, Ahyeon; Gutbrod, Sarah R.; Meyers, Jason D.; Lu, Chaofeng; Webb, Richard Chad; Shin, Gunchul; Li, Yuhang; Kang, Seung-Kyun; Huang, Yonggang
2016-01-01
Knowledge of the distributions of temperature in cardiac tissue during and after ablation is important in advancing a basic understanding of this process, and for improving its efficacy in treating arrhythmias. Technologies that enable real-time temperature detection and thermal characterization in the transmural direction can help to predict the depths and sizes of lesion that form. Herein, materials and designs for an injectable device platform that supports precision sensors of temperature and thermal transport properties distributed along the length of an ultrathin and flexible needle-type polymer substrate are introduced. The resulting system can insert into the myocardial tissue, in a minimally invasive manner, to monitor both radiofrequency ablation and cryoablation, in a manner that has no measurable effects on the natural mechanical motions of the heart. The measurement results exhibit excellent agreement with thermal simulations, thereby providing improved insights into lesion transmurality. PMID:26648177
Alberti, Nicolas; Buy, Xavier; Frulio, Nora; Montaudon, Michel; Canella, Mathieu; Gangi, Afshin; Crombe, Amandine; Palussière, Jean
2016-06-01
Among image-guided thermo-ablative techniques, percutaneous radiofrequency ablation (PRFA) is the most widely used technique for the treatment of primary and secondary lung malignancies. Tolerance of PRFA in the lung is excellent. However, relatively little is known about potential rare complications. This article presents both the clinical and imaging features of lung PRFA complications as well as their prevention and management. Complications may be classified in four groups: pleuropulmonary (e.g., bronchopleural or bronchial fistula, delayed abscess or aspergilloma inside post-PRFA cavitations, pulmonary artery pseudo aneurysm, gas embolism and interstitial pneumonia); thoracic wall and vertebral (e.g., rib or vertebral fractures and intercostal artery injury); mediastinal and apical (e.g., neural damage); or diaphragmatic. Most complications can be managed with conservative treatment, percutaneous or endoscopic drainage, or surgical repair. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crombé, Amandine, E-mail: amandine.crombe@ens-lyon.fr; Buy, Xavier; Godbert, Yann
An 82-year-old man, who was diagnosed in 2002 with an oncocytic (Hürthle cell) thyroid carcinoma, was initially treated by local surgery and was refractory to radioiodine treatment. The patient had successive secondary recurrences from 2006 onwards. Metastases were suspected due to an elevation of thyroglobulin in serum. Hypermetabolic nodules were targeted using FDG PET as well as CT-guided radiofrequency ablations. Thyroglobulin levels decreased following each procedure. 10 years later, tolerance and efficacy are excellent; 23 lung metastases have been treated during 11 sessions without current relapse. Respiratory function and quality of life are not altered. This report illustrates how radiofrequencymore » ablation can be efficiently integrated into the long-term management of poorly aggressive oligometastatic cancer, in combination with other local and/or systemic therapies.« less
Beryllium implosion experiments at high case-to-capsule ratio on the National Ignition Facility
NASA Astrophysics Data System (ADS)
Zylstra, Alex; Yi, Austin; Kline, John; Kyrala, George; Loomis, Eric; Perry, Ted; Shah, Rahul; Batha, Steve; MacLaren, Steve; Ralph, Joe; Salmonson, Jay; Masse, Laurent; Nikroo, Abbas; Stadermann, Michael; Callahan, Debbie; Hurricane, Omar; Rice, Neal; Huang, Haibo; Kong, Casey
2017-10-01
Using beryllium as an ablator material has several potential advantages for inertial fusion because of its low opacity and thus higher ablation rate. This could enable novel designs taking advantage of the reduced ablation-front growth rate, or operating at lower radiation temperature. To investigate the integrated performance of beryllium implosions, we conducted a tuning campaign leading into DT layered implosions using a 900um radius capsule in a 6.72mm diameter hohlraum (case-to-capsule ratio CCR=3.7); the large CCR enables direct study of the 1-D implosion performance. The tuning campaign shots demonstrate excellent control over the shock timing and implosion symmetry at this CCR. Performance data from the DT experiments will also be discussed. This work was performed under the auspices of the U.S. DoE by LANL under contract DE-AC52-06NA52396.
NASA Astrophysics Data System (ADS)
Wang, Y. M.; Xiong, X.; Zhao, Z. W.; Xie, L.; Min, X. B.; Yan, J. H.; Xia, G. M.; Zheng, F.
2015-08-01
Tungsten nozzle was produced by plasma spray forming (PSF, relative density of 86 ± 2%) followed by hot isostatic pressing (HIPing, 97 ± 2%) at 2000 °C and 180 MPa for 180 min. Scanning electron microscope, x-ray diffractometer, Archimedes method, Vickers hardness, and tensile tests have been employed to study microstructure, phase composition, density, micro-hardness, and mechanical properties of the parts. Resistance of thermal shock and ablation behavior of W nozzle were investigated by hot-firing test on solid rocket motor (SRM). Comparing with PSF nozzle, less damage was observed for HIPed sample after SRM test. Linear ablation rate of nozzle made by PSF was (0.120 ± 0.048) mm/s, while that after HIPing reduced to (0.0075 ± 0.0025) mm/s. Three types of ablation mechanisms including mechanical erosion, thermophysical erosion, and thermochemical ablation took place during hot-firing test. The order of degree of ablation was nozzle throat > convergence > dilation inside W nozzle.
Manivasagan, Panchanathan; Bharathiraja, Subramaniyan; Santha Moorthy, Madhappan; Oh, Yun-Ok; Song, Kyeongeun; Seo, Hansu; Oh, Junghwan
2017-05-03
The development of novel photothermal ablation agents as cancer nanotheranostics has received a great deal of attention in recent decades. Biocompatible fucoidan (Fu) is used as the coating material for gold nanorods (AuNRs) and subsequently conjugated with monoclonal antibodies against epidermal growth factor receptor (anti-EGFR) as novel photothermal ablation agents for cancer nanotheranostics because of their excellent biocompatibility, biodegradability, nontoxicity, water solubility, photostability, ease of surface modification, strongly enhanced absorption in near-infrared (NIR) regions, target specificity, minimal invasiveness, fast recovery, and prevention of damage to normal tissues. Anti-EGFR Fu-AuNRs have an average particle size of 96.37 ± 3.73 nm. Under 808 nm NIR laser at 2 W/cm 2 for 5 min, the temperature of the solution containing anti-EGFR Fu-AuNRs (30 μg/mL) increased by 52.1 °C. The anti-EGFR Fu-AuNRs exhibited high efficiency for the ablation of MDA-MB-231 cells in vitro. In vivo photothermal ablation exhibited that tumor tissues fully recovered without recurrence and finally were reconstructed with normal tissues by the 808 nm NIR laser irradiation after injection of anti-EGFR Fu-AuNRs. These results suggest that the anti-EGFR Fu-AuNRs would be novel photoablation agents for future cancer nanotheranostics.
Study on mechanical and ablative properties of EPDM/OMMT thermal insulating nanocomposites.
Gao, Guoxin; Zhang, Zhicheng; Li, Xuefei; Meng, Qingjie; Zheng, Yuansuo; Jin, Zhihao
2010-11-01
In order to enhance the elongation at break, the ablation resistant properties as well as the tensile strength of the thermal insulating materials, organo-montmorillonite (OMMT) was introduced into the short aramid fibers reinforced Ethylene-Propylene-Diene Monomer (EPDM) based nanocomposites. The effects of OMMT content on the mechanical and ablative properties of the nanocomposites were investigated systematically. X-ray diffraction (XRD) and transmission electron microscopy (TEM) confirm that EPDM-matrix has been intercalated into OMMT interlayers after a mixing process on a two-roll mill. The brittle fracture of nanocomposites also indicates that OMMT can lubricate aramid fiber to weaken the interfacial adhesive strength between the fibers and the matrix. As a result, the tensile strength and elongation at break are both improved sharply with OMMT content increasing from 1 phr to 7 phr. However, thanks to the inevitable agglomeration of OMMT with high loading inside the nanocomposites, the tensile strength and elongation at break reduce gently once OMMT is over 7 phr. Furthermore, the ablation resistant properties are improved greatly by increasing OMMT from 1 phr to 11 phr. Therefore, the optimal content of OMMT is 7-11 phr for the thermal insulating nanocomposites with big elongation and excellent ablation resistant properties.
Microwave ablation of hepatocellular carcinoma
Poggi, Guido; Tosoratti, Nevio; Montagna, Benedetta; Picchi, Chiara
2015-01-01
Although surgical resection is still the optimal treatment option for early-stage hepatocellular carcinoma (HCC) in patients with well compensated cirrhosis, thermal ablation techniques provide a valid non-surgical treatment alternative, thanks to their minimal invasiveness, excellent tolerability and safety profile, proven efficacy in local disease control, virtually unlimited repeatability and cost-effectiveness. Different energy sources are currently employed in clinics as physical agents for percutaneous or intra-surgical thermal ablation of HCC nodules. Among them, radiofrequency (RF) currents are the most used, while microwave ablations (MWA) are becoming increasingly popular. Starting from the 90s’, RF ablation (RFA) rapidly became the standard of care in ablation, especially in the treatment of small HCC nodules; however, RFA exhibits substantial performance limitations in the treatment of large lesions and/or tumors located near major heat sinks. MWA, first introduced in the Far Eastern clinical practice in the 80s’, showing promising results but also severe limitations in the controllability of the emitted field and in the high amount of power employed for the ablation of large tumors, resulting in a poor coagulative performance and a relatively high complication rate, nowadays shows better results both in terms of treatment controllability and of overall coagulative performance, thanks to the improvement of technology. In this review we provide an extensive and detailed overview of the key physical and technical aspects of MWA and of the currently available systems, and we want to discuss the most relevant published data on MWA treatments of HCC nodules in regard to clinical results and to the type and rate of complications, both in absolute terms and in comparison with RFA. PMID:26557950
Wire ablation dynamics model and its application to imploding wire arrays of different geometries.
Esaulov, A A; Kantsyrev, V L; Safronova, A S; Velikovich, A L; Shrestha, I K; Williamson, K M; Osborne, G C
2012-10-01
The paper presents an extended description of the amplified wire ablation dynamics model (WADM), which accounts in a single simulation for the processes of wire ablation and implosion of a wire array load of arbitrary geometry and wire material composition. To investigate the role of wire ablation effects, the implosions of cylindrical and planar wire array loads at the university based generators Cobra (Cornell University) and Zebra (University of Nevada, Reno) have been analyzed. The analysis of the experimental data shows that the wire mass ablation rate can be described as a function of the current through the wire and some coefficient defined by the wire material properties. The aluminum wires were found to ablate with the highest rate, while the copper ablation is the slowest one. The lower wire ablation rate results in a higher inward velocity of the ablated plasma, a higher rate of the energy coupling with the ablated plasma, and a more significant delay of implosion for a heavy load due to the ablation effects, which manifest the most in a cylindrical array configuration and almost vanish in a single-planar array configuration. The WADM is an efficient tool suited for wire array load design and optimization in wide parameter ranges, including the loads with specific properties needed for the inertial confinement fusion research and laboratory astrophysics experiments. The data output from the WADM simulation can be used to simplify the radiation magnetohydrodynamics modeling of the wire array plasma.
Method for continuous control of composition and doping of pulsed laser deposited films
Lowndes, Douglas H.; McCamy, James W.
1995-01-01
A method for growing a deposit upon a substrate of semiconductor material involves the utilization of pulsed laser deposition techniques within a low-pressure gas environment. The substrate and a target of a first material are positioned within a deposition chamber and a low-pressure gas atmosphere is developed within the chamber. The substrate is then heated, and the target is irradiated, so that atoms of the target material are ablated from the remainder of the target, while atoms of the gas simultaneously are adsorbed on the substrate/film surface. The ablated atoms build up upon the substrate, together with the adsorbed gas atoms to form the thin-film deposit on the substrate. By controlling the pressure of the gas of the chamber atmosphere, the composition of the formed deposit can be controlled, and films of continuously variable composition or doping can be grown from a single target of fixed composition.
Lowndes, Douglas H.; McCamy, James W.
1996-01-01
A method for growing a deposit upon a substrate of semiconductor material involves the utilization of pulsed laser deposition techniques within a low-pressure gas environment. The substrate and a target of a first material are positioned within a deposition chamber and a low-pressure gas atmosphere is developed within the chamber. The substrate is then heated, and the target is irradiated, so that atoms of the target material are ablated from the remainder of the target, while atoms of the gas simultaneously are adsorbed on the substrate/film surface. The ablated atoms build up upon the substrate, together with the adsorbed gas atoms to form the thin-film deposit on the substrate. By controlling the pressure of the gas of the chamber atmosphere, the composition of the formed deposit can be controlled, and films of continuously variable composition or doping can be grown from a single target of fixed composition.
Cho, Yirang; Lee, H.W.; Fountain, S.T.; Lubman, D.M.
1994-01-01
Trace quantities of laser ablated organic polymers were analyzed by using commercial capillary column gas chromatography/mass spectrometry; the instrument was modified so that the laser ablation products could be introduced into the capillary column directly and the constituents of each peak in the chromatogram were identified by using a mass spectrometer. The present study takes advantage of the selective ion monitoring mode for significantly improving the sensitivity of the mass spectrometer as a detector, which is critical in analyzing the trace quantities and confirming the presence or absence of the species of interest in laser ablated polymers. The initial composition of the laser ablated polymers was obtained by using an electron impact reflectron time-of-flight mass spectrometer and the possible structure of the fragments observed in the spectra was proposed based on the structure of the polymers.
NASA Astrophysics Data System (ADS)
Nishikawa, Hiroaki; Hasegawa, Tsukasa; Miyake, Akiko; Tashiro, Yuichiro; Komasa, Satoshi; Hashimoto, Yoshiya
2018-01-01
The dependence of the surface morphology and chemical composition of hydroxyapatite (HA) thin films on the laser fluence and ambient gas pressure during their formation by pulsed laser deposition was studied as the first step to investigate the effect of physical and chemical interactions between the ablated chemical species and ambient gas molecules on HA film formation. It was found that a higher fluence could decrease the number of large protrusions on the surface of HA thin films. However, too high a fluence caused a phosphorus deficiency from the stoichiometric value, particularly in the case of lower ambient gas pressure. It was also found that for lower fluences, the atomic species among the ablated chemical species were easily scattered by collision processes with ambient gas molecules. This was caused by the lower velocity of the ablated chemical species and higher ambient gas pressure, which induced a shorter mean free path. In addition, these collision processes played an important role in the adsorption, migration, and re-evaporation of the ablated chemical species on the substrate via chemical reactions.
NASA Astrophysics Data System (ADS)
Breves, E. A.; Lepore, K.; Dyar, M. D.; Bender, S. C.; Tokar, R. L.; Boucher, T.
2017-11-01
Laser-induced breakdown spectroscopy has become a popular tool for rapid elemental analysis of geological materials. However, quantitative applications of LIBS are plagued by variability in collected spectra that cannot be attributed to differences in geochemical composition. Even under ideal laboratory conditions, variability in LIBS spectra creates a host of difficulties for quantitative analysis. This is only exacerbated during field work, when both the laser-sample distance and the angle of ablation/collection are constantly changing. A primary goal of this study is to use empirical evidence to provide a more accurate assessment of uncertainty in LIBS-derived element predictions. We hope to provide practical guidance regarding the angles of ablation and collection that can be tolerated without substantially increasing prediction uncertainty beyond that which already exists under ideal laboratory conditions. Spectra were collected from ten geochemically diverse samples at angles of ablation and collection ranging from 0° to ± 60°. Ablation and collection angles were changed independently and simultaneously in order to isolate spectral changes caused by differences in ablation angle from those due to differences in collection angle. Most of the variability in atomic and continuum spectra is attributed to changes in the ablation angle, rather than the collection angle. At higher angles, the irradiance of the laser beam is lower and produces smaller, possibly less dense plasmas. Simultaneous changes in the collection angle do not appear to affect the collected spectra, possibly because smaller plasmas are still within the viewing area of the collection optics, even though this area is reduced at higher collection angles. A key observation is that changes in the magnitude of atomic and total emission are < 5% and 10%, respectively, in spectra collected with the configuration that most closely resembles field measurements (VV) at angles < 20°. In addition, variability in atomic and continuum emission is strongly dependent upon sample composition. Denser, more Fe/Mg-rich rocks exhibited much less variability with changes in ablation and collection angles than Si-rich felsic rocks. Elemental compositions of our variable angle data that were predicted using a much larger but conventionally-collected calibration suite show that accuracy generally suffers when the incidence and collection angles are high. Prediction accuracy (for measurements acquired with varying collection and ablation angles) varies from ± 1.28-1.86 wt% for Al2O3, ± 1.25-1.66 wt% for CaO, ± 1.90-2.21 wt% for Fe2O3T, ± 0.76-0.94 wt% for K2O, ± 2.85-3.61 wt% MgO, ± 0.15-0.17 wt% for MnO, ± 0.68-0.78 wt% for Na2O, ± 0.33-0.42 wt% for TiO2, and ± 2.94-4.34 wt% SiO2. The ChemCam team is using lab data acquired under normal incidence and collection angles to predict the compositions of Mars targets at varying angles. Thus, the increased errors noted in this study for high incidence angle measurements are likely similar to additional, unacknowledged errors on ChemCam results for non-normal targets analyzed on Mars. Optimal quantitative analysis of LIBS spectra must include some knowledge of the angle of ablation and collection so the approximate increase in uncertainty introduced by a departure from normal angles can be accurately reported.
Fabrication of Composite Combustion Chamber/Nozzle for Fastrac Engine
NASA Technical Reports Server (NTRS)
Lawerence, T.; Beshears, R.; Burlingame, S.; Peters, W.; Prince, M.; Suits, M.; Tillery, S.; Burns, L.; Kovach, M.; Roberts, K.;
2000-01-01
The Fastrac Engine developed by the Marshall Space Flight Center for the X-34 vehicle began as a low cost engine development program for a small booster system. One of the key components to reducing the engine cost was the development of an inexpensive combustion chamber/nozzle. Fabrication of a regeneratively cooled thrust chamber and nozzle was considered too expensive and time consuming. In looking for an alternate design concept, the Space Shuttle's Reusable Solid Rocket Motor Project provided an extensive background with ablative composite materials in a combustion environment. An integral combustion chamber/nozzle was designed and fabricated with a silica/phenolic ablative liner and a carbon/epoxy structural overwrap. This paper describes the fabrication process and developmental hurdles overcome for the Fastrac engine one-piece composite combustion chamber/nozzle.
Fabrication of Composite Combustion Chamber/Nozzle for Fastrac Engine
NASA Technical Reports Server (NTRS)
Lawrence, T.; Beshears, R.; Burlingame, S.; Peters, W.; Prince, M.; Suits, M.; Tillery, S.; Burns, L.; Kovach, M.; Roberts, K.
2001-01-01
The Fastrac Engine developed by the Marshall Space Flight Center for the X-34 vehicle began as a low cost engine development program for a small booster system. One of the key components to reducing the engine cost was the development of an inexpensive combustion chamber/nozzle. Fabrication of a regeneratively cooled thrust chamber and nozzle was considered too expensive and time consuming. In looking for an alternate design concept, the Space Shuttle's Reusable Solid Rocket Motor Project provided an extensive background with ablative composite materials in a combustion environment. An integral combustion chamber/nozzle was designed and fabricated with a silica/phenolic ablative liner and a carbon/epoxy structural overwrap. This paper describes the fabrication process and developmental hurdles overcome for the Fastrac engine one-piece composite combustion chamber/nozzle.
Infiltrated carbon foam composites
NASA Technical Reports Server (NTRS)
Lucas, Rick D. (Inventor); Danford, Harry E. (Inventor); Plucinski, Janusz W. (Inventor); Merriman, Douglas J. (Inventor); Blacker, Jesse M. (Inventor)
2012-01-01
An infiltrated carbon foam composite and method for making the composite is described. The infiltrated carbon foam composite may include a carbonized carbon aerogel in cells of a carbon foam body and a resin is infiltrated into the carbon foam body filling the cells of the carbon foam body and spaces around the carbonized carbon aerogel. The infiltrated carbon foam composites may be useful for mid-density ablative thermal protection systems.
Correa-Afonso, Alessandra M; Pécora, Jesus Djalma; Palma-Dibb, Regina G
2008-06-01
The purpose of this study was to assess the efficacy of Er:YAG laser energy for composite resin removal and the influence of pulse repetition rate on the thermal alterations occurring during laser ablation. Composite resin filling was placed in cavities (1.0 mm deep) prepared in bovine teeth and the specimens were randomly assigned to five groups according to the technique used for composite filling removal. In group I (controls), the restorations were removed using a high-speed diamond bur. In the other groups, the composite fillings were removed using an Er:YAG laser with different pulse repetition rates: group 2-2 Hz; group 3-4 Hz; group 4-6 Hz; and group 5-10 Hz. The time required for complete removal of the restorative material and the temperature changes were recorded. Temperature rise during composite resin removal with the Er:YAG laser occurred in the substrate underneath the restoration and was directly proportional to the increase in pulse repetition rate. None of the groups had a temperature increase during composite filling removal of more than 5.6 degrees C, which is considered the critical point above which irreversible thermal damage to the pulp may result. Regarding the time for composite filling removal, all the laser-ablated groups (except for group 5 [10 Hz]) required more time than the control group for complete elimination of the material from the cavity walls. Under the tested conditions, Er:YAG laser irradiation was efficient for composite resin ablation and did not cause a temperature increase above the limit considered safe for the pulp. Among the tested pulse repetition rates, 6 Hz produced minimal temperature change compared to the control group (high-speed bur), and allowed composite filling removal within a time period that is acceptable for clinical conditions.
NASA Astrophysics Data System (ADS)
Neuland, M. B.; Grimaudo, V.; Mezger, K.; Moreno-García, P.; Riedo, A.; Tulej, M.; Wurz, P.
2016-03-01
A key interest of planetary space missions is the quantitative determination of the chemical composition of the planetary surface material. The chemical composition of surface material (minerals, rocks, soils) yields fundamental information that can be used to answer key scientific questions about the formation and evolution of the planetary body in particular and the Solar System in general. We present a miniature time-of-flight type laser ablation/ionization mass spectrometer (LMS) and demonstrate its capability in measuring the elemental and mineralogical composition of planetary surface samples quantitatively by using a femtosecond laser for ablation/ionization. The small size and weight of the LMS make it a remarkable tool for in situ chemical composition measurements in space research, convenient for operation on a lander or rover exploring a planetary surface. In the laboratory, we measured the chemical composition of four geological standard reference samples USGS AGV-2 Andesite, USGS SCo-l Cody Shale, NIST 97b Flint Clay and USGS QLO-1 Quartz Latite with LMS. These standard samples are used to determine the sensitivity factors of the instrument. One important result is that all sensitivity factors are close to 1. Additionally, it is observed that the sensitivity factor of an element depends on its electron configuration, hence on the electron work function and the elemental group in agreement with existing theory. Furthermore, the conformity of the sensitivity factors is supported by mineralogical analyses of the USGS SCo-l and the NIST 97b samples. With the four different reference samples, the consistency of the calibration factors can be demonstrated, which constitutes the fundamental basis for a standard-less measurement-technique for in situ quantitative chemical composition measurements on planetary surface.
Percutaneous intrapericardial echocardiography during catheter ablation: a feasibility study.
Horowitz, Barbara Natterson; Vaseghi, Marmar; Mahajan, Aman; Cesario, David A; Buch, Eric; Valderrábano, Miguel; Boyle, Noel G; Ellenbogen, Kenneth A; Shivkumar, Kalyanam
2006-11-01
Percutaneous pericardial access, epicardial mapping, and ablation have been used successfully for catheter ablation procedures. The purpose of this study was to evaluate the safety and feasibility of closed-chest direct epicardial ultrasound imaging for aiding cardiac catheter ablation procedures. An intracardiac ultrasound catheter was used for closed-chest epicardial imaging of the heart in 10 patients undergoing percutaneous epicardial access for catheter ablation. All patients underwent concomitant intracardiac echocardiography and preprocedural transesophageal echocardiography. Using a double-wire technique, two sheaths were placed in the pericardium, and a phased-array ultrasound catheter was manipulated within the pericardial sinuses for imaging. Multiple images from varying angles were obtained for catheter navigation. Notably, image stability was excellent, and structures such as the left atrial appendage were seen in great detail. No complications resulting from use of the ultrasound catheter in the pericardium occurred, and no restriction of movement due to the presence of the additional catheter in the pericardial space was observed. Wall motion was correlated to voltage maps in five patients and showed that areas of scars correlated with wall-motion abnormalities. Normal wall-motion score correlated to sensed signals of 4.2 +/- 0.3 mV (normal myocardium >1.5 mV), and scores >1 correlated to areas with signals <0.5 mV in that territory). Intrapericardial imaging using an ultrasound catheter is feasible and safe and has the potential to provide additional valuable information for complex ablation procedures.
Laser ablation-miniature mass spectrometer for elemental and isotopic analysis of rocks.
Sinha, M P; Neidholdt, E L; Hurowitz, J; Sturhahn, W; Beard, B; Hecht, M H
2011-09-01
A laser ablation-miniature mass spectrometer (LA-MMS) for the chemical and isotopic measurement of rocks and minerals is described. In the LA-MMS method, neutral atoms ablated by a pulsed laser are led into an electron impact ionization source, where they are ionized by a 70 eV electron beam. This results in a secondary ion pulse typically 10-100 μs wide, compared to the original 5-10 ns laser pulse duration. Ions of different masses are then spatially dispersed along the focal plane of the magnetic sector of the miniature mass spectrometer (MMS) and measured in parallel by a modified CCD array detector capable of detecting ions directly. Compared to conventional scanning techniques, simultaneous measurement of the ion pulse along the focal plane effectively offers a 100% duty cycle over a wide mass range. LA-MMS offers a more quantitative assessment of elemental composition than techniques that detect ions directly generated by the ablation process because the latter can be strongly influenced by matrix effects that vary with the structure and geometry of the surface, the wavelength of the laser beam, and the not well characterized ionization efficiencies of the elements in the process. The above problems attendant to the direct ion analysis has been minimized in the LA-MMS by analyzing the ablated neutral species after their post-ionization by electron impaction. These neutral species are much more abundant than the directly ablated ions in the ablated vapor plume and are, therefore, expected to be characteristic of the chemical composition of the solid. Also, the electron impact ionization of elements is well studied and their ionization cross sections are known and easy to find in databases. Currently, the LA-MMS limit of detection is 0.4 wt.%. Here we describe LA-MMS elemental composition measurements of various minerals including microcline, lepidolite, anorthoclase, and USGS BCR-2G samples. The measurements of high precision isotopic ratios including (41)K/(39)K (0.077 ± 0.004) and (29)Si/(28)Si (0.052 ± 0.006) in these minerals by LA-MMS are also described. The LA-MMS has been developed as a prototype instrument system for space applications for geochemical and geochronological measurements on the surface of extraterrestrial bodies. © 2011 American Institute of Physics
Zhang, Xuemei; Zheng, Yuanyi; Wang, Zhigang; Huang, Shuai; Chen, Yu; Jiang, Wei; Zhang, Hua; Ding, Mingxia; Li, Qingshu; Xiao, Xiaoqiu; Luo, Xin; Wang, Zhibiao; Qi, Hongbo
2014-06-01
High intensity focused ultrasound (HIFU) has attracted the great attention in tumor ablation due to its non-invasive, efficient and economic features. However, HIFU ablation has its intrinsic limitations for removing the residual tumor cells, thus the tumor recurrence and metastasis cannot be avoided in this case. Herein, we developed a multifunctional targeted poly(lactic-co-glycolic acid) (PLGA) nanobubbles (NBs), which not only function as an efficient ultrasound contrast agent for tumor imaging, but also a targeted anticancer drug carrier and excellent synergistic agent for enhancing the therapeutic efficiency of HIFU ablation. Methotrexate (MTX)-loaded NBs were synthesized and filled with perfluorocarbon gas subsequently using a facile but general double emulsion evaporation method. The active tumor-targeting monoclonal anti-HLA-G antibodies (mAbHLA-G) were further conjugated onto the surface of nanobubbles. The mAbHLA-G/MTX/PLGA NBs could enhance the ultrasound imaging both in vitro and in vivo, and the targeting efficiency to HLA-G overexpressing JEG-3 cells has been demonstrated. The elaborately designed mAbHLA-G/MTX/PLGA NBs can specifically target to the tumor cells both in vitro and in vivo, and their blood circulation time in vivo was much longer than non-targeted MTX/PLGA NBs. Further therapeutic evaluations showed that the targeted NBs as a synergistic agent can significantly improve the efficiency of HIFU ablation by changing the acoustic environment, and the focused ultrasound can promote the on-demand MTX release both in vitro and in vivo. The in vivo histopathology test and immunohistochemical analysis showed that the mAbHLA-G/MTX/PLGA NBs plus HIFU group presented most serious coagulative necrosis, the lowest proliferation index and the highest apoptotic index. Therefore, the successful introduction of targeted mAbHLA-G/MTX/PLGA NBs provides an excellent platform for the highly efficient, imaging-guided and non-invasive HIFU synergistic therapy of cancer with the supplementary functions of killing residual tumor cells and preventing tumor recurrence/metastasis. Copyright © 2014 Elsevier Ltd. All rights reserved.
A comparison of the DPSS UV laser ablation characteristic of 1024 and H10F WC-Co
NASA Astrophysics Data System (ADS)
See, Tian Long; Chantzis, Dimitrios; Royer, Raphael; Metsios, Ioannis; Antar, Mohammad; Marimuthu, Sundar
2017-07-01
An investigation on ablation characteristics of 1024 and H10F cobalt cemented tungsten carbide (WC-Co) with a DPSS nanosecond UV laser (50 ns pulse width, 355 nm wavelength, 90 W average power and 10 kHz repetition rate) is presented. The ablation characteristic parameters such as ablation threshold, incubation effect and optical penetration depth were evaluated based on the spot ablation diameter and depth. It was observed that the ablation threshold is significantly influenced by the number of pulses (NOP) and it decreases with increase NOP which is attributed to the incubation effect. Only one ablation region is observed at low laser fluence and an additional molten ablation region is observed at high laser fluence accompanied with cracks. The cracks formation is due to the thermal induced stress and changes in WC microstructure during laser beam irradiation. The crack depth is proportional to the thickness of the molten WC region. The ablation threshold of 1024 WC-Co and H10F WC-Co were found to be Fth1 =4.32 J/cm2 and Fth1 =4.26 J/cm2 respectively. The difference in chemical composition has insignificant effect on the ablation threshold value of the material. The incubation factor and optical penetration depth values of 1024 WC-Co and H10F WC-Co were found to be ξ=0.73, α-1 =411 nm and ξ=0.75, α-1 =397 nm respectively.
NASA Astrophysics Data System (ADS)
Almirall, Jose R.; Montero, Shirly; Furton, Kenneth G.
2002-08-01
The importance of glass as evidence of association between a crime event and a suspect has been recognized for some time. Glass is a fragile material that is often found at the scenes of crimes such as burglaries, hit-and-run accidents and violent crime offenses. The physical and chemical properties of glass can be used to differentiate between possible sources and as evidence of association between two fragments of glass thought to originate from the same source. Refractive index (RI) comparisons have been used for this purpose but due to the improved control over glass manufacturing processes, RI values often cannot differentiate glasses, even if the glass originates from different sources. Elemental analysis methods such as NAA, XRF, ICP-AES, and Inductively Coupled Plasma Mass Spectrometry (ICP-MS) have also been used for the comparison of trace elemental compositions and these techniques have been shown to provide an improvement in the discrimination of glass fragments over RI comparisons alone. The multi-element capability and the sensitivity of ICP-MS combined with the simplified sample introduction of laser ablation prior to ion detection provides for an excellent and relatively non-destructive technique for elemental analysis of glass fragments. The methodology for solution analysis (digestion procedure) and solid sample analysis (laser ablation) of glass is reported and the analytical results are compared. An isotope dilution method is also reported as a high precision technique for elemental analysis of glass fragments. The optimum sampling parameters for laser ablation, for semi-quantitative analysis and element ratio comparisons are also presented. Finally, the results of a case involving the breaking of 15 vehicle windows in an airport parking lot and the association of a suspect to the breakings by the glass fragments found on his person are also presented.
Impact of radiofrequency ablation geometry on electrical conduction
NASA Astrophysics Data System (ADS)
Rivas, Rhiana N.; Lye, Theresa H.; Hendon, Christine P.
2018-02-01
The gold standard of current treatment for atrial fibrillation is radiofrequency ablation (RFA). Single RFA procedures have low long-term, single-procedure success rates, which can be attributed to factors including inability to measure and visualize lesion depth in real time and incomplete knowledge of how atrial fibrillation manifests and persists. One way to address this problem is to develop a heart model that accurately fits lesion dimensions and depth using OCT to extract structural information. Twenty-three lesions of varying transmurality in left and right swine atrial tissue have been imaged with a Thorlabs OCT system with 6.5-micron axial resolution and a custom Ultra High Resolution system with 2.5-micron axial resolution. The boundaries of the ablation lesions were identified by the appearance of the birefringence artifact to identify areas of un-ablated tissue, as well as by changes to depth penetration and structural features, including decreased contrast between the endocardium and myocardium and disappearance of collagen fibers within the ablation lesion. Using these features, the lateral positions of the lesion boundaries were identified. An algorithm that fit ellipses to the lesion contours modeled the ablation geometry in depth. Lesion dimensions and shape were confirmed by comparison with trichrome histological processing. Finite-element models were fitted with these parameters and electrophysiological simulations were run with the Continuity 6 package. Next steps include correlating lesion geometry to conduction velocity, and including further tissue complexity such as varying tissue composition and fiber orientation. Additional models of linear lesions with gaps and adjacent lesions created with non-perpendicular contact will be created. This work will provide insight into how lesion geometry, tissue composition, and fiber organization impact electrophysiological propagation.
Laser-based mass spectrometry for in situ chemical composition analysis of planetary surfaces
NASA Astrophysics Data System (ADS)
Frey, Samira; Neuland, Maike B.; Grimaudo, Valentine; Moreno-García, Pavel; Riedo, Andreas; Tulej, Marek; Broekmann, Peter; Wurz, Peter
2016-04-01
Mass spectrometry is an important analytical technique in space research. The chemical composition of planetary surface material is a key scientific question on every space mission to a planet, moon or asteroid. Chemical composition measurements of rocky material on the surface are of great importance to understand the origin and evolution of the planetary body.[1] A miniature laser ablation/ionisation reflectron- type time-of-flight mass spectrometer (instrument name LMS) was designed and built at the University of Bern for planetary research.[2] Despite its small size and light weight, the LMS instrument still maintains the same capabilities as large laboratory systems, which makes it suitable for its application on planetary space missions.[3-5] The high dynamic range of about eight orders of magnitude, high lateral (μm-level) and vertical (sub-nm level) resolution and high detection sensitivity for almost all elements (10 ppb, atomic fraction) make LMS a versatile instrument for various applications. LMS is a suitable instrument for in situ measurements of elemental and isotope composition with high precision and accuracy. Measurements of Pb- isotope abundances can be used for dating of planetary material. Measurements of bio-relevant elements allow searching for past or present life on a planetary surface. The high spatial resolution, both in lateral and vertical direction, is of considerable interest, e.g. for analysis of inhomogeneous, extraterrestrial samples as well as weathering processes of planetary material. References [1] P. Wurz, D. Abplanalp, M. Tulej, M. Iakovleva, V.A. Fernandes, A. Chumikov, and G. Managadze, "Mass Spectrometric Analysis in Planetary Science: Investigation of the Surface and the Atmosphere", Sol. Sys. Res., 2012, 46, 408. [2] U. Rohner, J.A. Whitby, P. Wurz, "A miniature laser ablation time of flight mass spectrometer for in situ planetary exploration" Meas. Sci. Tch., 2003, 14, 2159. [3] M. Tulej, A. Riedo, M.B. Neuland, S. Meyer, P. Wurz, N. Thomas, V. Grimaudo, P. Moreno-García, P. Broekmann, A. Neubeck and M. Ivarsson, "CAMAM: A miniature laser ablation ionisation mass spectrometer and microscope-camera system for in situ investigation of the composition and morphology of extraterrestrial materials", Geostand. Geoanal. Res., 2014, 38, 441. [4] A. Riedo, M. Neuland, S. Meyer, M. Tulej and P. Wurz, "Coupling of LMS with a fs-laser ablation ion source: elemental and isotope composition measurements", J. Anal. At. Spectrom., 2013, 28, 1256. [5] A. Riedo, S. Meyer, B. Heredia, M. Neuland, A. Bieler, M. Tulej, I. Leya, M. Iakovleva, K. Mezger and P. Wurz, "Highly accurate isotope composition measurements by a miniature laser ablation mass spectrometer designed for in situ investigations on planetary surfaces", Planet. Space Sci., 2013, 87, 1.
Apparatus for depositing a low work function material
Balooch, Mehdi; Dinh, Long N.; Siekhaus, Wigbert J.
2006-10-10
Short-wavelength photons are used to ablate material from a low work function target onto a suitable substrate. The short-wavelength photons are at or below visible wavelength. The elemental composition of the deposit is controlled by the composition of the target and the gaseous environment in which the ablation process is performed. The process is carried out in a deposition chamber to which a short-wavelength laser is mounted and which includes a substrate holder which can be rotated, tilted, heated, or cooled. The target material is mounted onto a holder that spins the target during laser ablation. In addition, the deposition chamber is provided with a vacuum pump, an external gas supply with atomizer and radical generator, a gas generator for producing a flow of molecules on the substrate, and a substrate cleaning device, such as an ion gun. The substrate can be rotated and tilted, for example, whereby only the tip of an emitter can be coated with a low work function material.
Structural and optical properties of novel surfactant-coated Yb@TiO2 nanoparticles
NASA Astrophysics Data System (ADS)
Calandra, P.; Lombardo, D.; Pistone, A.; Turco Liveri, V.; Trusso, S.
2011-11-01
In this paper a novel hybrid approach to synthesise composite nanoparticles is presented. It is based on the laser ablation of a bulk target (Yb) immersed in a reversed micellar solution which contains nanoparticles of a different host material (TiO2 nanoparticles) previously synthesised by chemical method. This approach thus exploits the advantages of the chemical synthesis through reversed micellar solution (size control, nanoparticle stabilisation), and of the laser ablation ("clean" synthesis, no side reactions). Central role is played by the microscopic processes controlling the deposition of the ablated Yb atoms onto the surface of TiO2 nanoparticles which actually behave as nucleation seeds. The structural features of the resulting Yb@TiO2 composite nanoparticles have been studied by Transmission Electron Microscopy, whereas their peculiar optical properties have been explored by UV-Vis spectroscopy and steady-state fluorescence. Results consistently show the formation of Yb and TiO2 glued nanodomains to form nearly spherical and non-interacting nanoparticles with enhanced photophysical properties.
Ablative performance of uncoated silicone-modified and shuttle baseline reinforced carbon composites
NASA Technical Reports Server (NTRS)
Dicus, D. L.; Hopko, R. N.; Brown, R. D.
1976-01-01
The relative ablative performance of uncoated silicone-modified reinforced carbon composite (RCC) and uncoated shuttle baseline RCC substrates was investigated. The test specimens were 13 plies (5.3 to 5.8 millimeters) thick and had a 25-millimeter-diameter test face. Prior to arc tunnel testing, all specimens were subjected to a heat treatment simulating the RCC coating process. During arc tunnel testing, the specimens were exposed to cold wall heating rates of 178 to 529 kilowatts/sq m and stagnation pressures ranging from 0.015 to 0.046 atmosphere at Mach 4.6 in air, with and without preheating in nitrogen. The results show that the ablative performance of uncoated silicone-modified RCC substrates is significantly superior to that of uncoated shuttle baseline RCC substrates over the range of heating conditions used. These results indicate that the silicone-modified RCC substrate would yield a substantially greater safety margin in the event of complete coating loss on the shuttle orbiter.
The role of external beam radiotherapy in the treatment of hepatocellular cancer.
Chino, Fumiko; Stephens, Sarah Jo; Choi, Steve S; Marin, Daniele; Kim, Charles Y; Morse, Michael A; Godfrey, Devon J; Czito, Brian G; Willett, Christopher G; Palta, Manisha
2018-04-12
Hepatocellular carcinoma (HCC) is increasing in incidence and mortality. Although the prognosis remains poor, long-term survival has improved from 3% in 1970 to an 18% 5-year survival rate today. This is likely because of the introduction of well tolerated, oral antiviral therapies for hepatitis C. Curative options for patients with HCC are often limited by underlying liver dysfunction/cirrhosis and medical comorbidities. Less than one-third of patients are candidates for surgery, which is the current gold standard for cure. Nonsurgical treatments include embolotherapies, percutaneous ablation, and ablative radiation. Technological advances in radiation delivery in the past several decades now allow for safe and effective ablative doses to the liver. Conformal techniques allow for both dose escalation to target volumes and normal tissue sparing. Multiple retrospective and prospective studies have demonstrated that hypofractionated image-guided radiation therapy, used as monotherapy or in combination with other liver-directed therapies, can provide excellent local control that is cost effective. Therefore, as the HCC treatment paradigm continues to evolve, ablative radiation treatment has moved from a palliative treatment to both a "bridge to transplant" and a definitive treatment. Cancer 2018. © 2018 American Cancer Society. © 2018 American Cancer Society.
Kaplan, Haim; Kaplan, Lilach
2016-12-01
In the recent years, there is a growth in demand for radiofrequency (RF)-based procedures to improve skin texture, laxity and contour. The new generation of systems allow non-invasive and fractional resurfacing treatments on one platform. The aim of this study was to evaluate the safety and efficacy of a new treatment protocol using a multisource RF, combining 3 different modalities in each patient: [1] non-ablative RF skin tightening, [2] fractional skin resurfacing, and [3] microneedling RF for non-ablative coagulation and collagen remodelling. 14 subjects were enrolled in this study using EndyMed PRO ™ platform. Each patient had 8 non-ablative treatments and 4 fractional treatments (fractional skin resurfacing and Intensif). The global aesthetic score was used to evaluate improvement. All patients had improvement in skin appearance. About 43% had excellent or very good improvement above 50%, 18% had good improvement between 25 and 50%, and the rest 39% had a mild improvement of < 25%. Downtime was minimal and no adverse effect was reported. Our data show significant improvement of skin texture, skin laxity and wrinkle reduction achieved using RF treatment platform.
Gilon, N; El-Haddad, J; Stankova, A; Lei, W; Ma, Q; Motto-Ros, V; Yu, J
2011-11-01
Laser ablation coupled to inductively coupled plasma optical emission spectrometry (LA-ICP-OES) and laser-induced breakdown spectroscopy (LIBS) were investigated for the determination of Ca, Mg, Zn and Na in milk samples. The accuracy of both methods was evaluated by comparison of the concentration found using LA-ICP-OES and LIBS with classical wet digestion associated with ICP-OES determination. The results were not fully acceptable, with biases from less than 1% to more than 60%. Matrix effects were also investigated. The sample matrix can influence the temperature, electron number density (n (e)) and other excitation characteristics in the ICP. These ICP characteristics were studied and evaluated during ablation of eight milk samples. Differences in n (e) (from 8.9 to 13.8 × 10(14) cm(-3)) and rotational temperature (ranging from 3,400 to 4,400 K) occurred with no correlation with trueness. LIBS results obtained after classical external calibration procedure gave degraded accuracy, indicating a strong matrix effect. The LIBS measurements clearly showed that the major problem in LA-ICP was related to the ablation process and that LIBS spectroscopy is an excellent diagnostic tool for LA-ICP techniques.
Numerical modeling on carbon fiber composite material in Gaussian beam laser based on ANSYS
NASA Astrophysics Data System (ADS)
Luo, Ji-jun; Hou, Su-xia; Xu, Jun; Yang, Wei-jun; Zhao, Yun-fang
2014-02-01
Based on the heat transfer theory and finite element method, the macroscopic ablation model of Gaussian beam laser irradiated surface is built and the value of temperature field and thermal ablation development is calculated and analyzed rationally by using finite element software of ANSYS. Calculation results show that the ablating form of the materials in different irritation is of diversity. The laser irradiated surface is a camber surface rather than a flat surface, which is on the lowest point and owns the highest power density. Research shows that the higher laser power density absorbed by material surface, the faster the irritation surface regressed.
NASA Astrophysics Data System (ADS)
Buckova, M.; Kasparova, M.; Dostalova, T.; Jelinkova, H.; Sulc, J.; Nemec, M.; Fibrich, M.; Bradna, P.; Miyagi, M.
2013-05-01
Laser radiation can be used for effective caries removal and cavity preparation without significant thermal effects, collateral damage of tooth structure, or patient discomfort. The aim of this study was to compare the quality of tissue after contact or non-contact Er:YAG and CTH:YAG laser radiation ablation. The second goal was to increase the sealing ability of hard dental tissues using sonic-activated bulk filling material with change in viscosity during processing. The artificial caries was prepared in intact teeth to simulate a demineralized surface and then the Er:YAG or CTH:YAG laser radiation was applied. The enamel artificial caries was gently removed by the laser radiation and sonic-activated composite fillings were inserted. A stereomicroscope and then a scanning electron microscope were used to evaluate the enamel surface. Er:YAG contact mode ablation in enamel was quick and precise; the cavity was smooth with a keyhole shaped prism and rod relief arrangement without a smear layer. The sonic-activated filling material was consistently regularly distributed; no cracks or microleakage in the enamel were observed. CTH:YAG irradiation was able to clean but not ablate the enamel surface; in contact and also in non-contact mode there was evidence of melting and fusing of the enamel.
NASA Astrophysics Data System (ADS)
Bykovskii, N. E.; Senatskii, Yu. V.
2018-02-01
The dynamics of Newton interference rings appearing in the ablation area on the surface of various condensed media under irradiation with femtosecond laser pulses is analyzed (according to published data on fs ablation). The data on the refractive index evolution in the expanding material cloud from the metal, semiconductor, and dielectric surface, obtained by interference pattern processing. The mechanism of the concentration of the energy absorbed by a medium from the laser beam in the thin layer under the irradiated sample surface is considered. The appearance of the inner layer with increased energy release explains why the ablation process from the metal, semiconductor, and dielectric surface, despite the differences in their compositions and radiation absorption mechanisms, occurs similarly, i.e., with the formation of a thin shell at the outer ablation cloud boundary, which consists of a condensed medium reflecting radiation and, together with the target surface, forms a structure necessary for interference formation.
Koh, Ahyeon; Gutbrod, Sarah R; Meyers, Jason D; Lu, Chaofeng; Webb, Richard Chad; Shin, Gunchul; Li, Yuhang; Kang, Seung-Kyun; Huang, Yonggang; Efimov, Igor R; Rogers, John A
2016-02-04
Knowledge of the distributions of temperature in cardiac tissue during and after ablation is important in advancing a basic understanding of this process, and for improving its efficacy in treating arrhythmias. Technologies that enable real-time temperature detection and thermal characterization in the transmural direction can help to predict the depths and sizes of lesion that form. Herein, materials and designs for an injectable device platform that supports precision sensors of temperature and thermal transport properties distributed along the length of an ultrathin and flexible needle-type polymer substrate are introduced. The resulting system can insert into the myocardial tissue, in a minimally invasive manner, to monitor both radiofrequency ablation and cryoablation, in a manner that has no measurable effects on the natural mechanical motions of the heart. The measurement results exhibit excellent agreement with thermal simulations, thereby providing improved insights into lesion transmurality. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Raiti, Paul
2008-06-01
Carbon dioxide (CO2) laser was used to treat multiple cutaneous papillomas on an adult female common snapping turtle, Chelydra serpentina serpentina. A combination of excisional and ablative techniques provided excellent intraoperative visibility and postoperative results due to the laser's unique ability to incise and vaporize soft tissue.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Rui, E-mail: ryang73@ustc.edu; Gudipati, Murthy S., E-mail: gudipati@jpl.nasa.gov
2014-03-14
In this work, we report for the first time successful analysis of organic aromatic analytes imbedded in D{sub 2}O ices by novel infrared (IR) laser ablation of a layered non-absorbing D{sub 2}O ice (spectator) containing the analytes and an ablation-active IR-absorbing H{sub 2}O ice layer (actor) without the analyte. With these studies we have opened up a new method for the in situ analysis of solids containing analytes when covered with an IR laser-absorbing layer that can be resonantly ablated. This soft ejection method takes advantage of the tenability of two-step infrared laser ablation and ultraviolet laser ionization mass spectrometry,more » previously demonstrated in this lab to study chemical reactions of polycyclic aromatic hydrocarbons (PAHs) in cryogenic ices. The IR laser pulse tuned to resonantly excite only the upper H{sub 2}O ice layer (actor) generates a shockwave upon impact. This shockwave penetrates the lower analyte-containing D{sub 2}O ice layer (spectator, a non-absorbing ice that cannot be ablated directly with the wavelength of the IR laser employed) and is reflected back, ejecting the contents of the D{sub 2}O layer into the vacuum where they are intersected by a UV laser for ionization and detection by a time-of-flight mass spectrometer. Thus, energy is transmitted from the laser-absorbing actor layer into the non-absorbing spectator layer resulting its ablation. We found that isotope cross-contamination between layers was negligible. We also did not see any evidence for thermal or collisional chemistry of PAH molecules with H{sub 2}O molecules in the shockwave. We call this “shockwave mediated surface resonance enhanced subsurface ablation” technique as “two-step laser ablation and ionization mass spectrometry of actor-spectator ice layers.” This method has its roots in the well-established MALDI (matrix assisted laser desorption and ionization) method. Our method offers more flexibility to optimize both the processes—ablation and ionization. This new technique can thus be potentially employed to undertake in situ analysis of materials imbedded in diverse media, such as cryogenic ices, biological samples, tissues, minerals, etc., by covered with an IR-absorbing laser ablation medium and study the chemical composition and reaction pathways of the analyte in its natural surroundings.« less
Synthesis and characterization of PVK/AgNPs nanocomposites prepared by laser ablation.
Abd El-Kader, F H; Hakeem, N A; Elashmawi, I S; Menazea, A A
2015-03-05
Nanocomposites of Poly (n-vinylcarbazole) PVK/Ag nanoparticles were prepared by laser ablation of a silver plate in aqueous solution of chlorobenzene. The influences of laser parameters such as; time of irradiation, source power and wavelength (photon energy) on structural, morphological and optical properties have been investigated using X-ray diffraction (XRD), Transmission electron microscopy (TEM), Ultraviolet-visible (UV-Vis) and Photoluminescence (PL). A correlation between the investigated properties has been discussed. XRD, TEM and PL indicated that the complexation between AgNPs and PVK in the composite system is possible. Only the reflection peak at 2θ=38° of AgNPs appeared in the composite nanoparticles while the other reflection peaks were destroyed. The nanoparticles shape and size distribution were evaluated from TEM images. TEM analysis revealed a lower average particle size at long laser irradiation time 40min and short laser wavelength 532nm together with high laser power 570mW. From UV-Visible spectra the values of absorption coefficient, absorption edge and energy tail were calculated. The reduction of band tail value with increasing the laser ablation parameters confirms the decrease of the disorder in such composite system. The PL and UV-Vis. spectra confirm that nanocomposite samples showed quantum confinement effect. Copyright © 2014 Elsevier B.V. All rights reserved.
Femtosecond laser lithotripsy: feasibility and ablation mechanism.
Qiu, Jinze; Teichman, Joel M H; Wang, Tianyi; Neev, Joseph; Glickman, Randolph D; Chan, Kin Foong; Milner, Thomas E
2010-01-01
Light emitted from a femtosecond laser is capable of plasma-induced ablation of various materials. We tested the feasibility of utilizing femtosecond-pulsed laser radiation (lambda=800 nm, 140 fs, 0.9 mJ/pulse) for ablation of urinary calculi. Ablation craters were observed in human calculi of greater than 90% calcium oxalate monohydrate (COM), cystine (CYST), or magnesium ammonium phosphate hexahydrate (MAPH). Largest crater volumes were achieved on CYST stones, among the most difficult stones to fragment using Holmium:YAG (Ho:YAG) lithotripsy. Diameter of debris was characterized using optical microscopy and found to be less than 20 microm, substantially smaller than that produced by long-pulsed Ho:YAG ablation. Stone retropulsion, monitored by a high-speed camera system with a spatial resolution of 15 microm, was negligible for stones with mass as small as 0.06 g. Peak shock wave pressures were less than 2 bars, measured by a polyvinylidene fluoride (PVDF) needle hydrophone. Ablation dynamics were visualized and characterized with pump-probe imaging and fast flash photography and correlated to shock wave pressures. Because femtosecond-pulsed laser ablates urinary calculi of soft and hard compositions, with micron-sized debris, negligible stone retropulsion, and small shock wave pressures, we conclude that the approach is a promising candidate technique for lithotripsy.
Bo, Xiao W; Li, Xiao L; Guo, Le H; Li, Dan D; Liu, Bo J; Wang, Dan; He, Ya P; Xu, Xiao H
2016-01-01
Objective: To evaluate the usefulness of two-dimensional quantitative ultrasound shear-wave elastography (2D-SWE) [i.e. virtual touch imaging quantification (VTIQ)] in assessing the ablation zone after radiofrequency ablation (RFA) for ex vivo swine livers. Methods: RFA was performed in 10 pieces of fresh ex vivo swine livers with a T20 electrode needle and 20-W output power. Conventional ultrasound, conventional strain elastography (SE) and VTIQ were performed to depict the ablation zone 0 min, 10 min, 30 min and 60 min after ablation. On VTIQ, the ablation zones were evaluated qualitatively by evaluating the shear-wave velocity (SWV) map and quantitatively by measuring the SWV. The ultrasound, SE and VTIQ results were compared against gross pathological and histopathological specimens. Results: VTIQ SWV maps gave more details about the ablation zone, the central necrotic zone appeared as red, lateral necrotic zone as green and transitional zone as light green, from inner to exterior, while the peripheral unablated liver appeared as blue. Conventional ultrasound and SE, however, only marginally depicted the whole ablation zone. The volumes of the whole ablation zone (central necrotic zone + lateral necrotic zone + transitional zone) and necrotic zone (central necrotic zone + lateral necrotic zone) measured by VTIQ showed excellent correlation (r = 0.915, p < 0.001, and 0.856, p = 0.002, respectively) with those by gross pathological specimen, whereas both conventional ultrasound and SE underestimated the volume of the whole ablation zone. The SWV values of the central necrotic zone, lateral necrotic zone, transitional zone and unablated liver parenchyma were 7.54–8.03 m s−1, 5.13–5.28 m s−1, 3.31–3.53 m s−1 and 2.11–2.21 m s−1, respectively (p < 0.001 for all the comparisons). The SWV value for each ablation zone did not change significantly at different observation times within an hour after RFA (all p > 0.05). Conclusion: The quantitative 2D-SWE of VTIQ is useful for the depiction of the ablation zone after RFA and it facilitates discrimination of different areas in the ablation zone qualitatively and quantitatively. This elastography technique might be useful for the therapeutic response evaluation instantly after RFA. Advances in knowledge: A new quantitative 2D-SWE (i.e. VTIQ) for evaluation treatment response after RFA is demonstrated. It facilitates discrimination of the different areas in the ablation zone qualitatively and quantitatively and may be useful for the therapeutic response evaluation instantly after RFA in the future. PMID:26933911
Low pressure laser ablation coupled to inductively coupled plasma mass spectrometry
NASA Astrophysics Data System (ADS)
Fliegel, Daniel; Günther, Detlef
2006-07-01
The particle size distribution in laser ablation inductively coupled plasma mass spectrometry is known to be a critical parameter for complete vaporization of particles. Any strategy to reduce the particle size distribution of laser generated aerosols has the potential to increase the ion signal intensity and to reduce fractionation effects. Due to the fact that vapor generation, nucleation, condensation, and agglomeration take place within an extremely short period of time, ablation under atmospheric pressure might not allow influencing these processes while under reduced pressure condition the cooling of the aerosol and therefore the condensation is expected to be slower. In this study, a low pressure laser ablation cell for the generation of laser aerosols was coupled to an ICP-MS. In contrast to the previously developed trapped ablation mode, the newly designed cell allows the adjustment of the pressure in the ablation cell between 20 and 1400 mbar prior to the ablation. Ablation experiments carried out using this configuration showed a dependence of the aerosol properties (size distribution and particle structure) on the ablation cell pressure. The intensity ratio U/Th measured as a figure of merit for complete vaporization within the ICP indicated a change in the aerosol structure at approximately 500 mbar toward smaller particle size. A significant difference between low pressure and at ambient pressure ablated aerosol was observed. The intensity ratios (U/Th) of the ablated sample moves closer to the bulk composition at lower pressures at the expense of sensitivity. Therefore the decrease in the ICP-MS signal intensity in the low pressure cell can be attributed to vapor deposition within the ablation cell walls. Moreover, scanning electron microscope images of aerosols collected on filters after the low pressure ablation cell suggest the possibility of a slower cooling velocity of the aerosol, which was observed in the condensed material on the surface of ejected spherical particles. The expansion of the laser aerosol was also investigated using polished brass substrates in the expansion path-way for particle collection.
Holá, Markéta; Mikuska, Pavel; Hanzlíková, Renáta; Kaiser, Jozef; Kanický, Viktor
2010-03-15
A study of LA-ICP-MS analysis of pressed powdered tungsten carbide precursors was performed to show the advantages and problems of nanosecond laser ablation of matrix-unified samples. Five samples with different compositions were pressed into pellets both with silver powder as a binder serving to keep the matrix unified, and without any binder. The laser ablation was performed by nanosecond Nd:YAG laser working at 213 nm. The particle formation during ablation of both sets of pellets was studied using an optical aerosol spectrometer allowing the measurement of particle concentration in two size ranges (10-250 nm and 0.25-17 microm) and particle size distribution in the range of 0.25-17 microm. Additionally, the structure of the laser-generated particles was studied after their collection on a filter using a scanning electron microscope (SEM) and the particle chemical composition was determined by an energy dispersive X-ray spectroscope (EDS). The matrix effect was proved to be reduced using the same silver powdered binder for pellet preparation in the case of the laser ablation of powdered materials. The LA-ICP-MS signal dependence on the element content present in the material showed an improved correlation for Co, Ti, Ta and Nb of the matrix-unified samples compared to the non-matrix-unified pellets. In the case of W, the ICP-MS signal of matrix-unified pellets was influenced by the changes in the particle formation. Copyright (c) 2009 Elsevier B.V. All rights reserved.
Influence of different propellant systems on ablation of EPDM insulators in overload state
NASA Astrophysics Data System (ADS)
Guan, Yiwen; Li, Jiang; Liu, Yang; Xu, Tuanwei
2018-04-01
This study examines the propellants used in full-scale solid rocket motors (SRM) and investigates how insulator ablation is affected by two propellant formulations (A and B) during flight overload conditions. An experimental study, theoretical analysis, and numerical simulations were performed to discover the intrinsic causes of insulator ablation rates from the perspective of lab-scaled ground-firing tests, the decoupling of thermochemical ablation, and particle erosion. In addition, the difference in propellant composition, and the insulator charring layer microstructure were analyzed. Results reveal that the degree of insulator ablation is positively correlated with the propellant burn rate, particle velocity, and aggregate concentrations during the condensed phase. A lower ratio of energetic additive material in the AP oxidizer of the propellant is promising for the reduction in particle size and increase in the burn rate and pressure index. However, the overall higher velocity of a two-phase flow causes severe erosion of the insulation material. While the higher ratio of energetic additive to the AP oxidizer imparts a smaller ablation rate to the insulator (under lab-scale test conditions), the slag deposition problem in the combustion chamber may cause catastrophic consequences for future large full-scale SRM flight experiments.
PICA Variants with Improved Mechanical Properties
NASA Technical Reports Server (NTRS)
Thornton, Jeremy; Ghandehari, Ehson M.; Fan, Wenhong; Stackpoole, Margaret; Chavez-Garcia, Jose
2011-01-01
Phenolic Impregnated Carbon Ablator (PICA) is a member of the family of Lightweight Ceramic Ablators (LCAs) and was developed at NASA Ames Research Center as a thermal protection system (TPS) material for the Stardust mission probe that entered the Earth s atmosphere faster than any other probe or vehicle to date. PICA, carbon fiberform base and phenolic polymer, shows excellent thermal insulative properties at heating rates from about 250 W/sq cm to 1000 W/sq cm. The density of standard PICA - 0.26 g/cu cm to 0.28 g/cu cm - can be changed by changing the concentration of the phenolic resin. By adding polymers to the phenolic resin before curing it is possible to significantly improve the mechanical properties of PICA without significantly increasing the density.
Using FT-IR Spectroscopy to Elucidate the Structures of Ablative Polymers
NASA Technical Reports Server (NTRS)
Fan, Wendy
2011-01-01
The composition and structure of an ablative polymer has a multifaceted influence on its thermal, mechanical and ablative properties. Understanding the molecular level information is critical to the optimization of material performance because it helps to establish correlations with the macroscopic properties of the material, the so-called structure-property relationship. Moreover, accurate information of molecular structures is also essential to predict the thermal decomposition pathways as well as to identify decomposition species that are fundamentally important to modeling work. In this presentation, I will describe the use of infrared transmission spectroscopy (FT-IR) as a convenient tool to aid the discovery and development of thermal protection system materials.
Analysis of composite ablators using massively parallel computation
NASA Technical Reports Server (NTRS)
Shia, David
1995-01-01
In this work, the feasibility of using massively parallel computation to study the response of ablative materials is investigated. Explicit and implicit finite difference methods are used on a massively parallel computer, the Thinking Machines CM-5. The governing equations are a set of nonlinear partial differential equations. The governing equations are developed for three sample problems: (1) transpiration cooling, (2) ablative composite plate, and (3) restrained thermal growth testing. The transpiration cooling problem is solved using a solution scheme based solely on the explicit finite difference method. The results are compared with available analytical steady-state through-thickness temperature and pressure distributions and good agreement between the numerical and analytical solutions is found. It is also found that a solution scheme based on the explicit finite difference method has the following advantages: incorporates complex physics easily, results in a simple algorithm, and is easily parallelizable. However, a solution scheme of this kind needs very small time steps to maintain stability. A solution scheme based on the implicit finite difference method has the advantage that it does not require very small times steps to maintain stability. However, this kind of solution scheme has the disadvantages that complex physics cannot be easily incorporated into the algorithm and that the solution scheme is difficult to parallelize. A hybrid solution scheme is then developed to combine the strengths of the explicit and implicit finite difference methods and minimize their weaknesses. This is achieved by identifying the critical time scale associated with the governing equations and applying the appropriate finite difference method according to this critical time scale. The hybrid solution scheme is then applied to the ablative composite plate and restrained thermal growth problems. The gas storage term is included in the explicit pressure calculation of both problems. Results from ablative composite plate problems are compared with previous numerical results which did not include the gas storage term. It is found that the through-thickness temperature distribution is not affected much by the gas storage term. However, the through-thickness pressure and stress distributions, and the extent of chemical reactions are different from the previous numerical results. Two types of chemical reaction models are used in the restrained thermal growth testing problem: (1) pressure-independent Arrhenius type rate equations and (2) pressure-dependent Arrhenius type rate equations. The numerical results are compared to experimental results and the pressure-dependent model is able to capture the trend better than the pressure-independent one. Finally, a performance study is done on the hybrid algorithm using the ablative composite plate problem. It is found that there is a good speedup of performance on the CM-5. For 32 CPU's, the speedup of performance is 20. The efficiency of the algorithm is found to be a function of the size and execution time of a given problem and the effective parallelization of the algorithm. It also seems that there is an optimum number of CPU's to use for a given problem.
NASA Astrophysics Data System (ADS)
Ying, Minju; Wang, XiaoXiao; Cheng, Wei; Liao, Bin; Zhang, Xu
2015-06-01
Optical emission spectra of the plasma produced by 1.06-μm Nd:YAG laser irradiation of a potassium titanyl phosphate (KTP) crystal were recorded and analyzed in a time- and spatially resolved manner. The composition and evolution of the plasma plume were studied in low vacuum conditions. Emission lines associated with Ti(I), Ti(II) and K(I) were identified in the plasma. The delay times of emission peaks for the ablated species were investigated as a function of the observation distance from the target surface, and the velocities of these species were derived accordingly. Two emission peaks corresponding to a fast and a slow component of ablated Ti(I) were observed by optical time-of-flight spectroscopy. The origins of the two peaks and a possible mechanism for the laser ablation are discussed.
Yu, Yiseul; Jung, Hyeon Jin; Je, Mingyu; Choi, Hyun Chul; Choi, Myong Yong
2016-07-01
In this work, the zero valent Fe (ZVI) and graphite-encapsulated Fe (Fe@C) nanoparticles (NPs) were easily and selectively prepared by a pulsed laser ablation (PLA) method in an aqueous sodium borohydride solution and ascorbic acid dissolved in methanol, respectively. Here, the Fe@C NPs were uniquely synthesized by PLA in methanol, where the solvent is used as both a carbon source for the graphitic layers and solvent, which is very unique. Furthermore, Pd NPs were loaded onto the surface of the Fe@C NPs to prepare bimetallic (Fe@C/Pd) NPs for the enhancement of the degradation efficiency of m-dichlorobenzene (m-DCB). The morphology, crystallinity, and surface composition of the prepared NPs were carefully characterized by high-resolution transmission electron microscopy (HRTEM), energy dispersive x-ray spectrometer (EDS), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS). The degradation rate of m-DCB using single (Fe and Pd) or bimetallic (Fe/Pd and Fe@C/Pd) NPs were compared by using gas chromatography. Among these NPs produced in this work, the Fe@C/Pd NPs with 1.71 wt % of Pd showed an excellent dechlorination efficiency for m-DCB with 100% degradation within 75 min. The graphitic layer on the Fe NPs played as not only an oxidation resistant for the Fe NPs to surroundings, but also a supporter of the Pd NPs for the enhanced degradation efficiency of m-DCB. Copyright © 2016 Elsevier Ltd. All rights reserved.
Effect of water on dental material ablation of the Er:YAG laser
NASA Astrophysics Data System (ADS)
Wigdor, Harvey A.; Visuri, Steven R.; Walsh, Joseph T., Jr.
1994-09-01
It is understood that if a laser is to replace the dental high speed handpiece it must be able to ablate dental materials which are present in teeth being treated with the laser. It is the intent of this paper to evaluate the effects of the Er:YAG laser on dental composite restorative material concentrating on the etch rate with and without waterspray. Composite dental material is used to form plugs of known thickness and the etch rate of the Er:YAG laser on this material is determined. The results are compared with those obtained from studies of the Er:YAG on dentin and enamel. In these studies the water reduced the efficiency of the Er:YAG laser 15 - 20% on these tissues.
Mesoscopic modeling of the response of human dental enamel to mid-infrared radiation
NASA Astrophysics Data System (ADS)
Vila Verde, Ana; Ramos, Marta; Stoneham, A. M.
2006-03-01
Ablation of human dental enamel, a composite biomaterial with water pores, is of significant importance in minimally invasive laser dentistry but progress in the area is hampered by the lack of optimal laser parameters. We use mesoscopic finite element models of this material to study its response to mid-infrared radiation. Our results indicate that the cost-effective, off-the-shelf CO2 laser at λ = 10.6 μm may in fact ablate enamel precisely, reproducibly and with limited unwanted side effects such as cracking or heating, provided that a pulse duration of 10 μs is used. Furthermore, our results also indicate that the Er:YAG laser (λ = 2.94 μm), currently popular for laser dentistry, may in fact cause unwanted deep cracking in the enamel when regions with unusually high water content are irradiated, and also provide an explanation for the large range of ablation threshold values observed for this material. The model may be easily adapted to study the response of any composite material to infrared radiation and thus may be useful for the scientific community.
NASA Astrophysics Data System (ADS)
Sanz, M.; López-Arias, M.; Rebollar, E.; de Nalda, R.; Castillejo, M.
2011-12-01
Nanostructured CdS and ZnS films on Si (100) substrates were obtained by nanosecond pulsed laser deposition at the wavelengths of 266 and 532 nm. The effect of laser irradiation wavelength on the surface structure and crystallinity of deposits was characterized, together with the composition, expansion dynamics and thermodynamic parameters of the ablation plume. Deposits were analyzed by environmental scanning electron microscopy, atomic force microscopy and X-ray diffraction, while in situ monitoring of the plume was carried out with spectral, temporal and spatial resolution by optical emission spectroscopy. The deposits consist of 25-50 nm nanoparticle assembled films but ablation in the visible results in larger aggregates (150 nm) over imposed on the film surface. The aggregate free films grown at 266 nm on heated substrates are thicker than those grown at room temperature and in the former case they reveal a crystalline structure congruent with that of the initial target material. The observed trends are discussed in reference to the light absorption step, the plasma composition and the nucleation processes occurring on the substrate.
Hilerowicz, Yuval; Koren, Amir; Mashiah, Jacob; Katz, Oren; Sprecher, Eli; Artzi, Ofir
2018-05-01
Leishmaniasis is a protozoan zoonotic parasitic infection with cutaneous, mucocutaneous, and visceral manifestations. Israel is endemic for cutaneous leishmaniasis, which is a self-limited disease but is associated with scarring, which is often a source of psychological and social burden for patients. Scars can be especially devastating for children and teenagers. A wide range of physical and medical approaches is used to treat cutaneous leishmaniasis, among which intralesional injections of sodium stibogluconate rank among the most frequently used. Unfortunately, despite being effective, this therapeutic modality can be very painful. Fractional ablative laser creates a controlled mesh-like pattern of tissue ablation in the skin that promotes dermal remodeling and collagen production while at the same time facilitating enhanced delivery of topically applied medications. Patients were treated with fractional ablative carbon dioxide laser followed by immediate topical application of sodium stibogluconate. All children were diagnosed with cutaneous leishmaniasis prior to treatment initiation.. Ten children were treated. One leishmania tropica-positive girl failed to respond. The other nine patients achieved clinical cure and demonstrated good to excellent final cosmesis. Self-rated patient satisfaction and tolerance were high No adverse effects were observed or reported during treatment. Fractional ablative carbon dioxide laser followed by topical sodium stibogluconate application appears to be a safe and promising treatment for cutaneous leishmaniasis infection in children. Future controlled studies are required to validate these findings and compare this technique with traditional approaches. © 2018 Wiley Periodicals, Inc.
Lunar Return Reentry Thermal Analysis of a Generic Crew Exploration Vehicle Wall Structures
NASA Technical Reports Server (NTRS)
Ko, William L.; Tran, Van T.; Bowles, Jeff
2007-01-01
Thermostructural analysis was performed on generic crew exploration vehicle (GCEV) heat shielded wall structures subjected to reentry heating rates based on five potential lunar return reentry trajectories. The GCEV windward outer wall is fabricated with a graphite/epoxy composite honeycomb sandwich panel and the inner wall with an aluminum honeycomb sandwich panel. The outer wall is protected with an ablative Avcoat-5026-39H/CG thermal protection system (TPS). A virtual ablation method (a graphical approximation) developed earlier was further extended, and was used to estimate the ablation periods, ablation heat loads, and the TPS recession layer depths. It was found that up to 83 95 percent of the total reentry heat load was dissipated in the TPS ablation process, leaving a small amount (3-15 percent) of the remaining total reentry heat load to heat the virgin TPS and maintain the TPS surface at the ablation temperature, 1,200 F. The GCEV stagnation point TPS recession layer depths were estimated to be in the range of 0.280-0.910 in, and the allowable minimum stagnation point TPS thicknesses that could maintain the substructural composite sandwich wall at the limit temperature of 300 F were found to be in the range of 0.767-1.538 in. Based on results from the present analyses, the lunar return abort ballistic reentry was found to be quite attractive because it required less TPS weight than the lunar return direct, the lunar return skipping, or the low Earth orbit guided reentry, and only 11.6 percent more TPS weight than the low Earth orbit ballistic reentry that will encounter a considerable weight penalty to obtain the Earth orbit. The analysis also showed that the TPS weight required for the lunar return skipping reentry was much more than the TPS weight necessary for any of the other reentry trajectories considered.
NASA Technical Reports Server (NTRS)
Sinha, Mahadeva P.; Hecht, Michael H.; Hurowitz, Joel A.
2012-01-01
A miniaturized instrument for performing chemical and isotopic analysis of rocks has been developed. The rock sample is ablated by a laser and the neutral species produced are analyzed using the JPL-invented miniature mass spectrometer. The direct sampling of neutral ablated material and the simultaneous measurement of all the elemental and isotopic species are the novelties of this method. In this laser ablation-miniature mass spectrometer (LA-MMS) method, the ablated neutral atoms are led into the electron impact ionization source of the MMS, where they are ionized by a 70-eV electron beam. This results in a secondary ion pulse typically 10-100 microsecond wide, compared to the original 5-10-nanosecond laser pulse duration. Ions of different masses are then spatially dispersed along the focal plane of the magnetic sector of the miniature mass spectrometer and measured in parallel by a modified CCD (charge-coupled device) array detector capable of detecting ions directly. Compared to conventional scanning techniques, simultaneous measurement of the ion pulse along the focal plane effectively offers a 100% duty cycle over a wide mass range. LAMMS offers a more quantitative assessment of elemental composition than techniques that detect laser-ionized species produced directly in the ablation process because the latter can be strongly influenced by matrix effects that vary with the structure and geometry of the surface, the laser beam, and the ionization energies of the elements. The measurement of high-precision isotopic ratios and elemental composition of different rock minerals by LAMMS method has been demonstrated. The LA-MMS can be applied for the absolute age determination of rocks. There is no such instrument available presently in a miniaturized version that can be used for NASA space missions. Work is in progress in the laboratory for geochronology of rocks using LA-MMS that is based on K-Ar radiogenic dating technique.
Ablation-resistant carbide Zr0.8Ti0.2C0.74B0.26 for oxidizing environments up to 3,000 °C
NASA Astrophysics Data System (ADS)
Zeng, Yi; Wang, Dini; Xiong, Xiang; Zhang, Xun; Withers, Philip J.; Sun, Wei; Smith, Matthew; Bai, Mingwen; Xiao, Ping
2017-06-01
Ultra-high temperature ceramics are desirable for applications in the hypersonic vehicle, rockets, re-entry spacecraft and defence sectors, but few materials can currently satisfy the associated high temperature ablation requirements. Here we design and fabricate a carbide (Zr0.8Ti0.2C0.74B0.26) coating by reactive melt infiltration and pack cementation onto a C/C composite. It displays superior ablation resistance at temperatures from 2,000-3,000 °C, compared to existing ultra-high temperature ceramics (for example, a rate of material loss over 12 times better than conventional zirconium carbide at 2,500 °C). The carbide is a substitutional solid solution of Zr-Ti containing carbon vacancies that are randomly occupied by boron atoms. The sealing ability of the ceramic's oxides, slow oxygen diffusion and a dense and gradient distribution of ceramic result in much slower loss of protective oxide layers formed during ablation than other ceramic systems, leading to the superior ablation resistance.
Ablation-resistant carbide Zr0.8Ti0.2C0.74B0.26 for oxidizing environments up to 3,000 °C.
Zeng, Yi; Wang, Dini; Xiong, Xiang; Zhang, Xun; Withers, Philip J; Sun, Wei; Smith, Matthew; Bai, Mingwen; Xiao, Ping
2017-06-14
Ultra-high temperature ceramics are desirable for applications in the hypersonic vehicle, rockets, re-entry spacecraft and defence sectors, but few materials can currently satisfy the associated high temperature ablation requirements. Here we design and fabricate a carbide (Zr 0.8 Ti 0.2 C 0.74 B 0.26 ) coating by reactive melt infiltration and pack cementation onto a C/C composite. It displays superior ablation resistance at temperatures from 2,000-3,000 °C, compared to existing ultra-high temperature ceramics (for example, a rate of material loss over 12 times better than conventional zirconium carbide at 2,500 °C). The carbide is a substitutional solid solution of Zr-Ti containing carbon vacancies that are randomly occupied by boron atoms. The sealing ability of the ceramic's oxides, slow oxygen diffusion and a dense and gradient distribution of ceramic result in much slower loss of protective oxide layers formed during ablation than other ceramic systems, leading to the superior ablation resistance.
Ablation-resistant carbide Zr0.8Ti0.2C0.74B0.26 for oxidizing environments up to 3,000 °C
Zeng, Yi; Wang, Dini; Xiong, Xiang; Zhang, Xun; Withers, Philip J.; Sun, Wei; Smith, Matthew; Bai, Mingwen; Xiao, Ping
2017-01-01
Ultra-high temperature ceramics are desirable for applications in the hypersonic vehicle, rockets, re-entry spacecraft and defence sectors, but few materials can currently satisfy the associated high temperature ablation requirements. Here we design and fabricate a carbide (Zr0.8Ti0.2C0.74B0.26) coating by reactive melt infiltration and pack cementation onto a C/C composite. It displays superior ablation resistance at temperatures from 2,000–3,000 °C, compared to existing ultra-high temperature ceramics (for example, a rate of material loss over 12 times better than conventional zirconium carbide at 2,500 °C). The carbide is a substitutional solid solution of Zr–Ti containing carbon vacancies that are randomly occupied by boron atoms. The sealing ability of the ceramic’s oxides, slow oxygen diffusion and a dense and gradient distribution of ceramic result in much slower loss of protective oxide layers formed during ablation than other ceramic systems, leading to the superior ablation resistance. PMID:28613275
NASA Astrophysics Data System (ADS)
Marques, Andrew J.; Jivraj, Jamil; Reyes, Robnier; Ramjist, Joel; Gu, Xijia J.; Yang, Victor X. D.
2017-02-01
Tissue removal using electrocautery is standard practice in neurosurgery since tissue can be cut and cauterized simultaneously. Thermally mediated tissue ablation using lasers can potentially possess the same benefits but with increased precision. However, given the critical nature of the spine, brain, and nerves, the effects of direct photo-thermal interaction on neural tissue needs to be known, yielding not only high precision of tissue removal but also increased control of peripheral heat damage. The proposed use of lasers as a neurosurgical tool requires that a common ground is found between ablation rates and resulting peripheral heat damage. Most surgical laser systems rely on the conversion of light energy into heat resulting in both desirable and undesirable thermal damage to the targeted tissue. Classifying the distribution of thermal energy in neural tissue, and thus characterizing the extent of undesirable thermal damage, can prove to be exceptionally challenging considering its highly inhomogenous composition when compared to other tissues such as muscle and bone. Here we present the characterization of neural tissue ablation rate and heat affected zone of a 1.94 micron thulium doped fiber laser for neural tissue ablation. In-Vivo ablation of porcine cerebral cortex is performed. Ablation volumes are studied in association with laser parameters. Histological samples are taken and examined to characterize the extent of peripheral heat damage.
Rhim, Jong-Whan; Wang, Long-Feng; Lee, Yonghoon; Hong, Seok-In
2014-03-15
Silver nanoparticles (AgNPs) were prepared by a laser ablation method and composite films with the AgNPs and agar were prepared by solvent casting method. UV-vis absorbance test and transmission electron microscopy (TEM) analysis results revealed that non-agglomerated spherical AgNPs were formed by the laser ablation method. The surface color of the resulting agar/AgNPs films exhibited the characteristic plasmonic effect of the AgNPs with the maximum absorption peaks of 400-407 nm. X-ray diffraction (XRD) test results also exhibited characteristic AgNPs crystals with diffraction peaks observed at 2θ values of 38.39°, 44.49°, and 64.45°, which were corresponding to (111), (200), and (220) crystallographic planes of face-centered cubic (fcc) silver crystals, respectively. Thermogravimetric analysis (TGA) results showed that thermal stability of the agar/AgNPs composite films was increased by the inclusion of metallic silver. Water vapor barrier properties and surface hydrophobicity of the agar/AgNPs films increased slightly with the increase in AgNPs content but they were not statistically significant (p>0.05), while mechanical strength and stiffness of the composite films decreased slightly (p<0.05). The agar/AgNPs films exhibited distinctive antimicrobial activity against both Gram-positive (Listeria monocytogenes) and Gram-negative (Escherichia coli O157:H7) bacterial pathogens. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Rudraswami, N. G.; Shyam Prasad, M.; Dey, S.; Plane, J. M. C.; Feng, W.; Taylor, S.
2015-11-01
We evaluate the heating of extraterrestrial particles entering the atmosphere using the comprehensive chemical ablation model (CABMOD). This model predicts the ablation rates of individual elements in a particle with a defined size, composition, entry velocity, and entry angle with respect to the zenith (ZA). In the present study, bulk chemical analyses of 1133 Antarctica micrometeorites (collected from the south pole water well) are interpreted using CABMOD. The marked spread in Fe/Si values in unmelted, partially melted, and melted micrometeorites is explained by the loss of relatively volatile Fe during atmospheric entry. The combined theoretical modeling and elemental composition of the micrometeorites (Mg/Si ratios) suggest that ˜85% of particles have a provenance of carbonaceous chondrites, the remaining ˜15% are either ordinary or enstatite chondrites. About 65% of the micrometeorites have undergone <20% ablation, while a further 20% have lost between 20% and 60% of their original mass. This has implications for understanding the micrometeorite flux that reaches the Earth's surface, as well as estimating the pre-atmospheric size of the particles. Our work shows that the unmelted particles that contribute ˜50% to the total micrometeorite collection on Earth's surface have a small entry zone: ZA = 60°-90° if the entry velocity is ˜11 km s-1, and ZA = 80°-90° for >11-21 km s-1.
Wear resistance of polypropylene-SiC composite
NASA Astrophysics Data System (ADS)
Abenojar, J.; Enciso, B.; Martínez, MA; Velasco, F.
2017-05-01
In this work, the wear resistance of thermoplastic composites with a high amount of ceramic is evaluated. Composites made of polypropylene (PP) and silicon carbide (SiC) powder at 50 wt% were used with the final objective of manufacturing ablative materials. This is the first part of a project studying the wear resistance and the mechanical properties of those composites, to be used in applications like habitat industry. In theory, the exposure to high temperature of ablative materials involves the elimination of thermal energy by the sacrifice of surface polymer. In our case, PP will act as a heat sink, up to the reaction temperature (melting or sublimation), where endothermic chemical decomposition into charred material and gaseous products occurs. As the surface is eroded, it is formed a SiC like-foam with improved insulation performance. Composites were produced by extrusion and hot compression. The wear characterization was performed by pin-on-disk test. Wear test was carried out under standard ASTM G99. The parameters were 120 rpm speed, 15 N load, a alumina ball with 6 mm as pin and 1000 m sliding distance. The tracks were also observed by opto-digital microscope.
Glass fiber addition strengthens low-density ablative compositions
NASA Technical Reports Server (NTRS)
Chandler, H. H.
1974-01-01
Approximately 15% of E-glass fibers was added to compositions under test and greatly improved char stability. Use of these fibers also reduced thermal strains which, in turn, minimized char shrinkage and associated cracks, subsurface voids, and disbonds. Increased strength allows honeycomb core reinforcement to be replaced by equivalent amount of glass fibers.
NASA Astrophysics Data System (ADS)
Zhao, Te; Ye, Hong; Zhang, Lisong; Cai, Qilin
2017-10-01
As typical phenolic resin-based ablative materials, the high silica/phenolic and carbon/phenolic composites are widely used in aerospace field. The specific heat of the carbonized ablators after ablation is an important thermophysical parameter in the process of heat transfer, but it is rarely reported. In this investigation, the carbonized samples of the high silica/phenolic and carbon/phenolic were obtained through carbonization experiments, and the specific heat of the carbonized samples was determined by a 3D DSC from 150 °C to 970 °C. Structural and compositional characterizations were performed to determine the mass fractions of the fiber and the carbonized product of phenolic which are the two constituents of the carbonized samples, while the specific heat of each constituent was also measured by 3D DSC. The masses of the carbonized samples were reduced when heated to a high temperature in the specific heat measurements, due to the thermal degradation of the carbonized product of phenolic resin in the carbonized samples. The raw experimental specific heat of the two carbonized samples and the carbonized product of phenolic resin was modified according to the quality changes of the carbonized samples presented by TGA results. Based on the mass fraction and the specific heat of each constituent, a weighted average method was adopted to obtain the calculated results of the carbonized samples. Due to the unconsolidated property of the fiber samples which impacts the reliability of the DSC measurement, there is a certain deviation between the experimental and calculated results of the carbonized samples. Considering the similarity of composition and structure, the data of quartz glass and graphite were used to substitute the specific heat of the high silica fiber and carbon fiber, respectively, resulting in better agreements with the experimental ones. Furthermore, the accurate specific heat of the high silica fiber and carbon fiber bundles was obtained by inversion, enabling the prediction of the specific heat of the carbonized ablators with different constituent mass fractions by means of the weighted average method in engineering.
Femtosecond laser ablation of enamel
NASA Astrophysics Data System (ADS)
Le, Quang-Tri; Bertrand, Caroline; Vilar, Rui
2016-06-01
The surface topographical, compositional, and structural modifications induced in human enamel by femtosecond laser ablation is studied. The laser treatments were performed using a Yb:KYW chirped-pulse-regenerative amplification laser system (560 fs and 1030 nm) and fluences up to 14 J/cm2. The ablation surfaces were studied by scanning electron microscopy, grazing incidence x-ray diffraction, and micro-Raman spectroscopy. Regardless of the fluence, the ablation surfaces were covered by a layer of resolidified material, indicating that ablation is accompanied by melting of hydroxyapatite. This layer presented pores and exploded gas bubbles, created by the release of gaseous decomposition products of hydroxyapatite (CO2 and H2O) within the liquid phase. In the specimen treated with 1-kHz repetition frequency and 14 J/cm2, thickness of the resolidified material is in the range of 300 to 900 nm. The micro-Raman analysis revealed that the resolidified material contains amorphous calcium phosphate, while grazing incidence x-ray diffraction analysis allowed detecting traces of a calcium phosphate other than hydroxyapatite, probably β-tricalcium phosphate Ca3), at the surface of this specimen. The present results show that the ablation of enamel involves melting of enamel's hydroxyapatite, but the thickness of the altered layer is very small and thermal damage of the remaining material is negligible.
Carbon Nanotube-enhanced Carbon-phenolic Ablator Material
NASA Technical Reports Server (NTRS)
Nikolaev, P.; Stackpoole, M.; Fan, W.; Cruden, B.; Waid, M.; Maloney, P.; Arepalli, S.; Arnold, J.; Partridge, H.; Yowell, L.
2006-01-01
Phenolic impregnated carbon ablator (PICA) is a thermal protection system (TPS) material developed at NASA Ames Research Center in the mid-90 s for Discovery missions. It was used on the Stardust return capsule heat shield which successfully executed the highest speed Earth entry to date on January 15, 2006. PICA is a porous fibrous carbon insulation infiltrated with phenolic resin, and is an excellent ablator that is effective for heating rates up to 1000 W/sq cm. It is one of several candidate TPS materials for the next generation of crewed spacecraft for Lunar and Mars missions. We will describe an ongoing research effort at NASA to improve mechanical properties of the phenolic matrix with carbon nanotubes. The aim is two-fold: to increase overall TPS strength during reentry and to improve Micrometeoroid/Orbital Debris (MMOD) protection in space. The former requires at least a good dispersion of nanotubes in phenolic, while the latter also requires covalent bonding between them to couple and transfer impact energy effectively from matrix to nanotubes. We will discuss the required chemical functionalization of nanotubes, processing issues and test results.
Low cost fabrication of ablative heat shields
NASA Technical Reports Server (NTRS)
Cecka, A. M.; Schofield, W. C.
1972-01-01
A material and process study was performed using subscale panels in an attempt to reduce the cost of fabricating ablative heat shield panels. Although no improvements were made in the material formulation, a significant improvement was obtained in the processing methods compared to those employed in the previous work. The principal feature of the new method is the press filling and curing of the ablation material in a single step with the bonding and curing of the face sheet. This method was chosen to replace the hand troweling and autoclave curing procedure used previously. Double-curvature panels of the same size as the flat panels were fabricated to investigate fabrication problems. It was determined that the same materials and processes used for flat panels can be used to produce the curved panels. A design with severe curvatures consisting of radii of 24 x 48 inches was employed for evaluation. Ten low-density and ten high-density panels were fabricated. With the exception of difficulties related to short run non-optimum tooling, excellent panel filling and density uniformity were obtained.
Cloud Ablation by a Relativistic Jet and the Extended Flare in CTA 102 in 2016 and 2017
NASA Astrophysics Data System (ADS)
Zacharias, M.; Böttcher, M.; Jankowsky, F.; Lenain, J.-P.; Wagner, S. J.; Wierzcholska, A.
2017-12-01
In late 2016 and early 2017, the flat spectrum radio quasar CTA 102 exhibited a very strong and long-lasting outburst. The event can be described by a roughly two-month long increase of the baseline flux in the monitored energy bands (optical to γ-rays) by a factor 8, and a subsequent decrease over another two months back to pre-flare levels. The long-term trend was superseded by short but very strong flares, resulting in a peak flux that was a factor 50 above pre-flare levels in the γ-ray domain and almost a factor 100 above pre-flare levels in the optical domain. In this paper, we explain the long-term evolution of the outburst by the ablation of a gas cloud penetrating the relativistic jet. The slice-by-slice ablation results in a gradual increase of the particle injection until the center of the cloud is reached, after which the injected number of particles decreases again. With reasonable cloud parameters, we obtain excellent fits of the long-term trend.
Casiello, Michele; Fusco, Caterina; Irrera, Alessia; Trusso, Sebastiano; Cotugno, Pietro
2018-01-01
Silicon nanowires (SiNWs) decorated by pulsed laser ablation with gold or copper nanoparticles (labeled as AuNPs@SiNWs and CuNPs@SiNWs) were investigated for their catalytic properties. Results demonstrated high catalytic performances in the Caryl–N couplings and subsequent carbonylations for gold and copper catalysts, respectively, that have no precedents in the literature. The excellent activity, attested by the very high turn over number (TON) values, was due both to the uniform coverage along the NW length and to the absence of the chemical shell surrounding the metal nanoparticles (MeNPs). A high recyclability was also observed and can be ascribed to the strong covalent interaction at the Me–Si interface by virtue of metal “silicides” formation. PMID:29385761
Casiello, Michele; Picca, Rosaria Anna; Fusco, Caterina; D'Accolti, Lucia; Leonardi, Antonio Alessio; Lo Faro, Maria Josè; Irrera, Alessia; Trusso, Sebastiano; Cotugno, Pietro; Sportelli, Maria Chiara; Cioffi, Nicola; Nacci, Angelo
2018-01-30
Silicon nanowires (SiNWs) decorated by pulsed laser ablation with gold or copper nanoparticles (labeled as AuNPs@SiNWs and CuNPs@SiNWs) were investigated for their catalytic properties. Results demonstrated high catalytic performances in the C aryl -N couplings and subsequent carbonylations for gold and copper catalysts, respectively, that have no precedents in the literature. The excellent activity, attested by the very high turn over number (TON) values, was due both to the uniform coverage along the NW length and to the absence of the chemical shell surrounding the metal nanoparticles (MeNPs). A high recyclability was also observed and can be ascribed to the strong covalent interaction at the Me-Si interface by virtue of metal "silicides" formation.
NASA Technical Reports Server (NTRS)
Cucinotta, Francis A.; Kim, Myung-Hee; Schneider, Irene; Hassler, Donald M.
2006-01-01
The atmosphere of Mars significantly attenuates the heavy ion component of the primary galactic cosmic rays (GCR), however increases the fluence of secondary light ions (neutrons, and hydrogen and helium isotopes) because of particle production processes. We describe results of the quantum multiple scattering fragmentation (QMSFRG) model for the production of light nuclei through the distinct mechanisms of nuclear abrasion and ablation, coalescence, and cluster knockout. The QMSFRG model is shown to be in excellent agreement with available experimental data for nuclear fragmentation cross sections. We use the QMSFRG model and the space radiation transport code, HZETRN to make predictions of the light particle environment on the Martian surface at solar minimum and maximum. The radiation assessment detector (RAD) experiment will be launched in 2009 as part of the Mars Science Laboratory (MSL). We make predictions of the expected results for time dependent count-rates to be observed by RAD experiment. Finally, we consider sensitivity assessments of the impact of the Martian atmospheric composition on particle fluxes at the surface.
NASA Astrophysics Data System (ADS)
Sammet, Steffen; Partanen, Ari; Yousuf, Ambereen; Wardrip, Craig; Niekrasz, Marek; Antic, Tatjana; Razmaria, Aria; Sokka, Sham; Karczmar, Gregory; Oto, Aytekin
2017-03-01
OBJECTIVES: Evaluation of the precision of prostate tissue ablation with MRI guided therapeuticultrasound by intraoperative objective assessment of the neurovascular bundle in canines in-vivo. METHODS: In this ongoing IACUC approved study, eight male canines were scanned in a clinical 3T Achieva MRI scanner (Philips) before, during, and after ultrasound therapy with a prototype MR-guided ultrasound therapy system (Philips). The system includes a therapy console to plan treatment, to calculate real-time temperature maps, and to control ultrasound exposures with temperature feedback. Atransurethral ultrasound applicator with eight transducer elements was used to ablate canine prostate tissue in-vivo. Ablated prostate tissue volumes were compared to the prescribed target volumes to evaluate technical effectiveness. The ablated volumes determined by MRI (T1, T2, diffusion, dynamic contrast enhanced and 240 CEM43 thermal dose maps) were compared to H&E stained histological slides afterprostatectomy. Potential nerve damage of the neurovascular bundle was objectively assessed intraoperativelyduring prostatectomy with a CaverMap Surgical Aid nerve stimulator (Blue Torch Medical Technologies). RESULTS: Transurethral MRI -guided ultrasound therapy can effectively ablate canine prostate tissue invivo. Coronal MR-imaging confirmed the correct placement of the HIFU transducer. MRI temperature maps were acquired during HIFU treatment, and subsequently used for calculating thermal dose. Prescribed target volumes corresponded to the 240 CEM43 thermal dose maps during HIFU treatment in all canines. Ablated volumes on high resolution anatomical, diffusion weighted, and contrast enhanced MR images matched corresponding histological slides after prostatectomy. MRI guidance with realtime temperature monitoring showed no damage to surrounding tissues, especially to the neurovascular bundle (assessed intra-operatively with a nerve stimulator) or to the rectum wall. CONCLUSIONS: Our study demonstrates the effectiveness and precision of transurethral ultrasound ablation of prostatic tissue in canines with MRI monitoring and guidance. The canine prostate is an excellent model for the human prostate with similar anatomical characteristics and diseases. MRI guidance with real-time, intraoperative temperature monitoring reduces the risk of damaging critical surrounding anatomical structures in ultrasound therapy of the prostate.
Winkle, Roger A; Moskovitz, Ryan; Hardwin Mead, R; Engel, Gregory; Kong, Melissa H; Fleming, William; Salcedo, Jonathan; Patrawala, Rob A; Tranter, John H; Shai, Isaac
2018-06-01
The optimal radiofrequency (RF) power and lesion duration using contact force (CF) sensing catheters for atrial fibrillation (AF) ablation are unknown. We evaluate 50 W RF power for very short durations using CF sensing catheters during AF ablation. We evaluated 51 patients with paroxysmal (n = 20) or persistent (n = 31) AF undergoing initial RF ablation. A total of 3961 50 W RF lesions were given (average 77.6 ± 19.1/patient) for an average duration of only 11.2 ± 3.7 s. As CF increased from < 10 to > 40 g, the RF application duration decreased from 13.7 ± 4.4 to 8.6 ± 2.5 s (p < 0.0005). Impedance drops occurred in all ablations, and for patients in sinus rhythm, there was loss of pacing capture during RF delivery suggesting lesion creation. Only 3% of the ablation lesions were at < 5 g and 1% at > 40 g of force. As CF increased, the force time integral (FTI) increased from 47 ± 24 to 376 ± 102 gs (p < 0.0005) and the lesion index (LSI) increased from 4.10 ± 0.51 to 7.63 ± 0.50 (p < 0.0005). Both procedure time (101 ± 19.7 min) and total RF energy time (895 ± 258 s) were very short. For paroxysmal AF, the single procedure freedom from AF was 86% at 1 and 2 years. For persistent AF, it was 83% at 1 year and 72% at 2 years. There were no complications. Short duration 50 W ablations using CF sensing catheters are safe and result in excellent long-term freedom from AF for both paroxysmal and persistent AF with short procedure times and small amounts of total RF energy delivery.
NASA Astrophysics Data System (ADS)
Najafzadeh Khoee, Ali Asghar; Habibolahzadeh, Ali; Qods, Fathallah; Baharvandi, Hamidreza
2015-04-01
In the present work, tungsten carbide (WC) preforms were fabricated by gel-casting process, using different nontoxic Na-alginate to tertiary calcium phosphate ratios and different loadings of WC powder in the initial slurries. The gel-cast green bodies were dried and pre-sintered at 1723 K for 4 h and then reactively infiltrated by molten Zr2Cu at 1623 K for 0.5 h, to produce W-ZrC composite via displacive compensation of porosity process. The phases, microstructures, and mechanical properties of the preforms and the W-ZrC composites were investigated by Fourier transform infrared spectroscope, x-ray diffractometer (XRD), scanning electron microscope (SEM), image analyzer, and universal mechanical testing machine. XRD results, SEM micrographs, and elemental maps indicated uniform distribution of phases (W and ZrC) and elements (W, Zr, and C). Flexural strengths and hardness of the fabricated composites were in the ranges of 429-460 MPa and 7.5-9.5 GPa, respectively. Fractography studies revealed two types of dimple rupture and cleavage fracture modes in different composite samples. The W-ZrC composite was ablated by an oxyacetylene flame for 60 s. The mean value of mass and linear ablation rates of the composite were 2.1 ± 0.1 mg/s and 3.6 ± 0.5 µm/s, respectively.
Calcified lesion modeling for excimer laser ablation
NASA Astrophysics Data System (ADS)
Scott, Holly A.; Archuleta, Andrew; Splinter, Robert
2009-06-01
Objective: Develop a representative calcium target model to evaluate penetration of calcified plaque lesions during atherectomy procedures using 308 nm Excimer laser ablation. Materials and Methods: An in-vitro model representing human calcified plaque was analyzed using Plaster-of-Paris and cement based composite materials as well as a fibrinogen model. The materials were tested for mechanical consistency. The most likely candidate(s) resulting from initial mechanical and chemical screening was submitted for ablation testing. The penetration rate of specific multi-fiber catheter designs and a single fiber probe was obtained and compared to that in human cadaver calcified plaque. The effects of lasing parameters and catheter tip design on penetration speed in a representative calcified model were verified against the results in human cadaver specimens. Results: In Plaster of Paris, the best penetration was obtained using the single fiber tip configuration operating at 100 Fluence, 120 Hz. Calcified human lesions are twice as hard, twice as elastic as and much more complex than Plaster of Paris. Penetration of human calcified specimens was highly inconsistent and varied significantly from specimen to specimen and within individual specimens. Conclusions: Although Plaster of Paris demonstrated predictable increases in penetration with higher energy density and repetition rate, it can not be considered a totally representative laser ablation model for calcified lesions. This is in part due to the more heterogeneous nature and higher density composition of cadaver intravascular human calcified occlusions. Further testing will require a more representative model of human calcified lesions.
Ablation and Thermal Response Property Model Validation for Phenolic Impregnated Carbon Ablator
NASA Technical Reports Server (NTRS)
Milos, F. S.; Chen, Y.-K.
2009-01-01
Phenolic Impregnated Carbon Ablator was the heatshield material for the Stardust probe and is also a candidate heatshield material for the Orion Crew Module. As part of the heatshield qualification for Orion, physical and thermal properties were measured for newly manufactured material, included emissivity, heat capacity, thermal conductivity, elemental composition, and thermal decomposition rates. Based on these properties, an ablation and thermal-response model was developed for temperatures up to 3500 K and pressures up to 100 kPa. The model includes orthotropic and pressure-dependent thermal conductivity. In this work, model validation is accomplished by comparison of predictions with data from many arcjet tests conducted over a range of stagnation heat flux and pressure from 107 Watts per square centimeter at 2.3 kPa to 1100 Watts per square centimeter at 84 kPa. Over the entire range of test conditions, model predictions compare well with measured recession, maximum surface temperatures, and in depth temperatures.
Flight and ground tests of a very low density elastomeric ablative material
NASA Technical Reports Server (NTRS)
Olsen, G. C.; Chapman, A. J., III
1972-01-01
A very low density ablative material, a silicone-phenolic composite, was flight tested on a recoverable spacecraft launched by a Pacemaker vehicle system; and, in addition, it was tested in an arc heated wind tunnel at three conditions which encompassed most of the reentry heating conditions of the flight tests. The material was composed, by weight, of 71 percent phenolic spheres, 22.8 percent silicone resin, 2.2 percent catalyst, and 4 percent silica fibers. The tests were conducted to evaluate the ablator performance in both arc tunnel and flight tests and to determine the predictability of the albator performance by using computed results from an existing one-dimensional numerical analysis. The flight tested ablator experienced only moderate surface recession and retained a smooth surface except for isolated areas where the char was completely removed, probably following reentry and prior to or during recovery. Analytical results show good agreement between arc tunnel and flight test results. The thermophysical properties used in the analysis are tabulated.
Partial ablation of Ti/Al nano-layer thin film by single femtosecond laser pulse
NASA Astrophysics Data System (ADS)
Gaković, B.; Tsibidis, G. D.; Skoulas, E.; Petrović, S. M.; Vasić, B.; Stratakis, E.
2017-12-01
The interaction of ultra-short laser pulses with Titanium/Aluminium (Ti/Al) nano-layered thin film was investigated. The sample composed of alternating Ti and Al layers of a few nanometres thick was deposited by ion-sputtering. A single pulse irradiation experiment was conducted in an ambient air environment using focused and linearly polarized femtosecond laser pulses for the investigation of the ablation effects. The laser induced morphological changes and the composition were characterized using several microscopy techniques and energy dispersive X-ray spectroscopy. The following results were obtained: (i) at low values of pulse energy/fluence, ablation of the upper Ti layer only was observed; (ii) at higher laser fluence, a two-step ablation of Ti and Al layers takes place, followed by partial removal of the nano-layered film. The experimental observations were supported by a theoretical model accounting for the thermal response of the multiple layered structure upon irradiation with ultra-short laser pulses.
Wah, Tze Min; Sourbron, Steven; Wilson, Daniel Jonathan; Magee, Derek; Gregory, Walter Martin; Selby, Peter John; Buckley, David L
2018-01-08
To investigate if the early treatment effects of radiofrequency ablation (RFA) on renal cell carcinoma (RCC) can be detected with dynamic contrast enhanced (DCE)-MRI and to correlate RCC perfusion with RFA treatment time. 20 patients undergoing RFA of their 21 RCCs were evaluated with DCE-MRI before and at one month after RFA treatment. Perfusion was estimated using the maximum slope technique at two independent sittings. Total RCC blood flow was correlated with total RFA treatment time, tumour location, size and histology. DCE-MRI examinations were successfully evaluated for 21 RCCs (size from 1.3 to 4 cm). Perfusion of the RCCs decreased significantly ( p < 0.0001) from a mean of 203 (±80) mL/min/100 mL before RFA to 8.1 (±3.1) mL/min/100 mL after RFA with low intra-observer variability ( r ≥ 0.99, p < 0.0001). There was an excellent correlation ( r = 0.95) between time to complete ablation and pre-treatment total RCC blood flow. Tumours with an exophytic location exhibit the lowest mean RFA treatment time. DCE-MRI can detect early treatment effects by measuring RCC perfusion before and after RFA. Perfusion significantly decreases in the zone of ablation, suggesting that it may be useful for the assessment of treatment efficacy. Pre-RFA RCC blood flow may be used to predict RFA treatment time.
Femtosecond laser ablation of gold interdigitated electrodes for electronic tongues
NASA Astrophysics Data System (ADS)
Manzoli, Alexandra; de Almeida, Gustavo F. B.; Filho, José A.; Mattoso, Luiz H. C.; Riul, Antonio; Mendonca, Cleber R.; Correa, Daniel S.
2015-06-01
Electronic tongue (e-tongue) sensors based on impedance spectroscopy have emerged as a potential technology to evaluate the quality and chemical composition of food, beverages, and pharmaceuticals. E-tongues usually employ transducers based on metal interdigitated electrodes (IDEs) coated with a thin layer of an active material, which is capable of interacting chemically with several types of analytes. IDEs are usually produced by photolithographic methods, which are time-consuming and costly, therefore, new fabrication technologies are required to make it more affordable. Here, we employed femtosecond laser ablation with pulse duration of 50 fs to microfabricate gold IDEs having finger width from 2.3 μm up to 3.2 μm. The parameters used in the laser ablation technique, such as light intensity, scan speed and beam spot size have been optimized to achieve uniform IDEs, which were characterized by optical and scanning electron microscopy. The electrical properties of gold IDEs fabricated by laser ablation were evaluated by impedance spectroscopy, and compared to those produced by conventional photolithography. The results show that femtosecond laser ablation is a promising alternative to conventional photolithography for fabricating metal IDEs for e-tongue systems.
Effects of Plume Hydrodynamics and Oxidation on the Composition of a Condensing Laser-Induced Plasma
Weisz, David G.; Crowhurst, Jonathan C.; Finko, Mikhail S.; ...
2018-02-01
High-temperature chemistry in laser ablation plumes leads to vapor-phase speciation, which can induce chemical fractionation during condensation. In this work, using emission spectroscopy acquired after ablation of a SrZrO 3 target, we have experimentally observed the formation of multiple molecular species (ZrO and SrO) as a function of time as the laser ablation plume evolves. Although the stable oxides SrO and ZrO 2 are both refractory, we observed emission from the ZrO intermediate at earlier times than SrO. We deduced the time-scale of oxygen entrainment into the laser ablation plume using an 18O 2 environment by observing the in-growth ofmore » Zr 18O in the emission spectra relative to Zr 16O, which was formed by reaction of Zr with 16O from the target itself. Using temporally resolved plume-imaging, we determined that ZrO formed more readily at early times, volumetrically in the plume, while SrO formed later in time, around the periphery. Lastly, using a simple temperature-dependent reaction model, we have illustrated that the formation sequence of these oxides subsequent to ablation is predictable to first order.« less
Bonta, Maximilian; Frank, Johannes; Taibl, Stefanie; Fleig, Jürgen; Limbeck, Andreas
2018-02-13
Advanced materials such as complex metal oxides are used in a wide range of applications and have further promising perspectives in the form of thin films. The exact chemical composition essentially influences the electronic properties of these materials which makes correct assessment of their composition necessary. However, due to high chemical resistance and in the case of thin films low absolute analyte amounts, this procedure is in most cases not straightforward and extremely time-demanding. Commonly applied techniques either lack in ease of use (i.e., solution-based analysis with preceding sample dissolution), or adequately accurate quantification (i.e., solid sampling techniques). An analysis approach which combines the beneficial aspects of solution-based analysis as well as direct solid sampling is Laser Ablation of a Sample in Liquid (LASIL). In this work, it is shown that the analysis of major as well as minor sample constituents is possible using a novel online-LASIL setup, allowing sample analysis without manual sample handling after placing it in an ablation chamber. Strontium titanate (STO) thin layers with different compositions were analyzed in the course of this study. Precision of the newly developed online-LASIL method is comparable to conventional wet chemical approaches. With only about 15-20 min required for the analysis per sample, time demand is significantly reduced compared to often necessary fusion procedures lasting multiple hours. Copyright © 2017 Elsevier B.V. All rights reserved.
Efficient analysis of complex natural materials using LA-ICP-MS
NASA Astrophysics Data System (ADS)
Kent, A. J.; Loewen, M. W.; Koleszar, A. M.; Miller, J.; Ungerer, C. "
2011-12-01
Many natural materials exhibit complex variations in chemical or isotopic composition over relatively short length scales, and these compositional variations often record important information about the environment or nature of the processes that lead to formation. Examples include complexly zoned crystals within volcanic rocks that record magmatic and volcanic signals, otoliths and other biominerals that record life history and environmental information, and speleothems that record climatic variables. Laser ablation ICP-MS analyses offer several advantages for quantifying compositional in chemically complex natural materials. These include the speed of analysis, the ability to sample at atmospheric pressures, the wide diversity of possible analytes, and the ability to make measurements in both spot and raster modes. The latter in particular offers advantages for analyses that require efficient acquisition of information over significant length scales, as in raster mode compositional data can be rapidly obtained by translating the laser laterally over a compositional variable material during a single analysis. In this fashion elemental or isotopic composition at a given analysis time corresponds to the lateral spatial dimension. This contrasts with a record obtained by a row of individual spots, which require a large number of discrete analyses, and requires significantly more analysis time. However there are also disadvantages to this style of analysis. Translation of the circular spots typically used for analysis results in significant signal attenuation and production of artifacts that may mirror natural diffusion profiles or other gradual changes. The ability to ablate using non-circular spots significantly reduces this effect, although the degree of attenuation is also increased by slower ablation cell response times. For single volume cells this may result in 50-100% additional attenuation than that produced by the translation of the spot alone, although two-volume and other rapid response cells significantly reduce this effect. Raster analyses are also highly sensitive to the presence of small contaminant phases along the raster trajectory, as the compositional signal from these can become attenuated and difficult to distinguish from natural compositional variations. It can also be difficult to establish exactly where compositional changes occur in materials that are visually homogenous. In this contribution we discuss these issues in more detail and present data acquisition and processing strategies that minimize these difficulties.
Sprayable low density ablator and application process
NASA Technical Reports Server (NTRS)
Sharpe, M. H.; Hill, W. E.; Simpson, W. G.; Carter, J. M.; Brown, E. L.; King, H. M.; Schuerer, P. H.; Webb, D. D. (Inventor)
1978-01-01
A sprayable, low density ablative composition is described consisting esentially of: (1) 100 parts by weight of a mixture of 25-65% by weight of phenolic microballoons, 0-20% by weight of glass microballoons, 4-10% by weight of glass fibers, 25-45% by weight of an epoxy-modified polyurethane resin, 2-4% by weight of a bentonite dispersing aid, and 1-2% by weight of an alcohol activator for the bentonite; (2) 1-10 parts by weight of an aromatic amine curing agent; and (3) 200-400 parts by weight of a solvent.
Pisa, S; Cavagnaro, M; Bernardi, P; Lin, J C
2001-05-01
A 915-MHz antenna design that produces specific absorption rate distributions with preferential power deposition in tissues surrounding and including the distal end of the catheter antenna is described. The design features minimal reflected microwave current from the antenna flowing up the transmission line. This cap-choke antenna consists of an annular cap and a coaxial choke which matches the antenna to the coaxial transmission line. The design minimizes heating of the coaxial cable and its performance is not affected by the depth of insertion of the antenna into tissue. The paper provides a comparison of results obtained from computer modeling and experimental measurements made in tissue equivalent phantom materials. There is excellent agreement between numerical modeling and experimental measurement. The cap-choke, matched-dipole type antenna is suitable for intracavitary microwave thermal ablation therapy.
Fractional nonablative laser resurfacing: is there a skin tightening effect?
Kauvar, Arielle N B
2014-12-01
Fractional photothermolysis, an approach to laser skin resurfacing that creates microscopic thermal wounds in skin separated by islands of spared tissue, was developed to overcome the high incidence of adverse events and prolonged healing times associated with full coverage ablative laser procedures. To examine whether fractional nonablative laser resurfacing induces skin tightening. A literature review was performed to evaluate the clinical and histologic effects of fractional nonablative laser resurfacing and full coverage ablative resurfacing procedures. Fractional nonablative lasers produce excellent outcomes with minimal risk and morbidity for a variety of clinical conditions, including photodamaged skin, atrophic scars, surgical and burn scars. Efforts to induce robust fibroplasia in histologic specimens and skin tightening in the clinical setting have yielded inconsistent results. A better understanding of the histology of fractional laser resurfacing will help to optimize clinical outcomes.
NASA Astrophysics Data System (ADS)
Gemayel, Rachel; Hellebust, Stig; Temime-Roussel, Brice; Hayeck, Nathalie; Van Elteren, Johannes T.; Wortham, Henri; Gligorovski, Sasho
2016-05-01
Hyphenated laser ablation-mass spectrometry instruments have been recognized as useful analytical tools for the detection and chemical characterization of aerosol particles. Here we describe the performances of a laser ablation aerosol particle time-of-flight mass spectrometer (LAAP-ToF-MS) which was designed for aerodynamic particle sizing using two 405 nm scattering lasers and characterization of the chemical composition of single aerosol particle via ablation/ionization by a 193 nm excimer laser and detection in a bipolar time-of-flight mass spectrometer with a mass resolving power of m/Δm > 600.
We describe a laboratory based optimization strategy for the development of an analytical methodology for characterization of atmospheric particles using the LAAP-ToF-MS instrument in combination with a particle generator, a differential mobility analyzer and an optical particle counter. We investigated the influence of particle number concentration, particle size and particle composition on the detection efficiency. The detection efficiency is a product of the scattering efficiency of the laser diodes and the ionization efficiency or hit rate of the excimer laser. The scattering efficiency was found to vary between 0.6 and 1.9 % with an average of 1.1 %; the relative standard deviation (RSD) was 17.0 %. The hit rate exhibited good repeatability with an average value of 63 % and an RSD of 18 %. In addition to laboratory tests, the LAAP-ToF-MS was used to sample ambient air during a period of 6 days at the campus of Aix-Marseille University, situated in the city center of Marseille, France. The optimized LAAP-ToF-MS methodology enables high temporal resolution measurements of the chemical composition of ambient particles, provides new insights into environmental science, and a new investigative tool for atmospheric chemistry and physics, aerosol science and health impact studies.
Chan, Kenneth H.; Hirasuna, Krista; Fried, Daniel
2015-01-01
Objective Dental composite restorative materials are color matched to the tooth and are difficult to remove by mechanical means without excessive removal or damage to peripheral enamel and dentin. Lasers are ideally suited for selective ablation to minimize healthy tissue loss when replacing existing restorations, sealants, or removing composite adhesives such as residual composite left after debonding orthodontic brackets. Methods In this study, a carbon dioxide laser operating at 9.3-μm with a pulse duration of 10–20-microsecond and a pulse repetition rate of ~200 Hz was integrated with a galvanometer based scanner and used to selectively remove composite from tooth surfaces. Spectra of the plume emission were acquired after each laser pulse and used to differentiate between the ablation of dental enamel or composite. Microthermocouples were used to monitor the temperature rise in the pulp chamber during composite removal. The composite was placed on tooth buccal and occlusal surfaces and the carbon dioxide laser beam was scanned across the surface to selectively remove the composite without excessive damage to the underlying sound enamel. The residual composite and the damage to the underlying enamel was evaluated using optical microscopy. Results The laser was able to rapidly remove composite from tooth buccal and occlusal surfaces with minimal damage to the underlying sound enamel and without excessive heat accumulation in the tooth. Conclusion This study demonstrated that composite can be selectively removed from tooth surfaces at clinically relevant rates using a CO2 laser operating at 9.3-μm with high pulse repetition rates with minimal heat deposition and damage to the underlying enamel. PMID:21956630
Chan, Kenneth H; Hirasuna, Krista; Fried, Daniel
2011-09-01
Dental composite restorative materials are color matched to the tooth and are difficult to remove by mechanical means without excessive removal or damage to peripheral enamel and dentin. Lasers are ideally suited for selective ablation to minimize healthy tissue loss when replacing existing restorations, sealants, or removing composite adhesives such as residual composite left after debonding orthodontic brackets. In this study, a carbon dioxide laser operating at 9.3-µm with a pulse duration of 10-20-microsecond and a pulse repetition rate of ∼200 Hz was integrated with a galvanometer based scanner and used to selectively remove composite from tooth surfaces. Spectra of the plume emission were acquired after each laser pulse and used to differentiate between the ablation of dental enamel or composite. Microthermocouples were used to monitor the temperature rise in the pulp chamber during composite removal. The composite was placed on tooth buccal and occlusal surfaces and the carbon dioxide laser beam was scanned across the surface to selectively remove the composite without excessive damage to the underlying sound enamel. The residual composite and the damage to the underlying enamel was evaluated using optical microscopy. The laser was able to rapidly remove composite from tooth buccal and occlusal surfaces with minimal damage to the underlying sound enamel and without excessive heat accumulation in the tooth. This study demonstrated that composite can be selectively removed from tooth surfaces at clinically relevant rates using a CO(2) laser operating at 9.3-µm with high pulse repetition rates with minimal heat deposition and damage to the underlying enamel. Copyright © 2011 Wiley-Liss, Inc.
The Composites Institute`s FirstSource directory
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-12-31
This book is the gateway to the composites industry, containing pertinent phone numbers along with a glossary of terms. The glossary is a complete listing of current composites terminology and their definitions, from Ablative Plastic to Young`s Modulus. Contents include: (1) corporate index; (2) manufacturing processes; (3) materials suppliers; (4) markets--parts/products/components; (5) tooling; (6) processing equipment and supplies; (7) distributors/agents; (8) consulting, testing and other services; (9) geographical listing; and (10) glossary.
Barium Isotopes in Single Presolar Grains
NASA Technical Reports Server (NTRS)
Pellin, M. J.; Davis, A. M.; Savina, M. R.; Kashiv, Y.; Clayton, R. N.; Lewis, R. S.; Amari, S.
2001-01-01
Barium isotopic compositions of single presolar grains were measured by laser ablation laser resonant ionization mass spectrometry and the implications of the data for stellar processes are discussed. Additional information is contained in the original extended abstract.
Abi-Jaoudeh, Nadine; Mielekamp, Peter; Noordhoek, Niels; Venkatesan, Aradhana M; Millo, Corina; Radaelli, Alessandro; Carelsen, Bart; Wood, Bradford J
2012-06-01
To describe a novel technique for multimodality positron emission tomography (PET) fusion-guided interventions that combines cone-beam computed tomography (CT) with PET/CT before the procedure. Subjects were selected among patients scheduled for a biopsy or ablation procedure. The lesions were not visible with conventional imaging methods or did not have uniform uptake on PET. Clinical success was defined by adequate histopathologic specimens for molecular profiling or diagnosis and by lack of enhancement on follow-up imaging for ablation procedures. Time to target (time elapsed between the completion of the initial cone-beam CT scan and first tissue sample or treatment), total procedure time (time from the moment the patient was on the table until the patient was off the table), and number of times the needle was repositioned were recorded. Seven patients underwent eight procedures (two ablations and six biopsies). Registration and procedures were completed successfully in all cases. Clinical success was achieved in all biopsy procedures and in one of the two ablation procedures. The needle was repositioned once in one biopsy procedure only. On average, the time to target was 38 minutes (range 13-54 min). Total procedure time was 95 minutes (range 51-240 min, which includes composite ablation). On average, fluoroscopy time was 2.5 minutes (range 1.3-6.2 min). An integrated cone-beam CT software platform can enable PET-guided biopsies and ablation procedures without the need for additional specialized hardware. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.
Boersma, Doeke; van Eekeren, Ramon R J P; Kelder, Hans J C; Werson, Debora A B; Holewijn, Suzanne; Schreve, Michiel A; Reijnen, Michel M P J; de Vries, Jean Paul P M
2014-10-29
Minimally invasive endothermal techniques, for example, radiofrequency ablation (RFA), have revolutionized the treatment of insufficient truncal veins and are associated with an excellent outcome. The use of thermal energy requires the instillation of tumescent anesthesia around the vein. Mechanochemical endovenous ablation (MOCA™) combines mechanical endothelial damage, using a rotating wire, with simultaneous infusion of a liquid sclerosans. Tumescent anesthesia is not required as no heat is used. Prospective studies using MOCA™ in both great and small saphenous veins showed good anatomical and clinical results with fast postoperative recovery. The MESSI trial (Mechanochemical Endovenous ablation versus radiofrequency ablation in the treatment of primary Small Saphenous vein Insufficiency) is a multicenter randomized controlled trial in which a total of 160 patients will be randomized (1:1) to MOCA™ or RFA. Consecutive patients with primary small saphenous vein incompetence, who meet the eligibility criteria, will be invited to participate in this trial. The primary endpoint is anatomic success, defined as occlusion of the treated veins objectified with duplex ultrasonography at 1 year follow-up. Secondary endpoints are post-procedural pain, initial technical success, clinical success, complications and the duration of the procedure. Initial technical success is defined as the ability to position the device adequately, treat the veins as planned and occlude the treated vein directly after the procedure has been proven by duplex ultrasonography. Clinical success is defined as an objective improvement of clinical outcome after treatment, measured with the Venous Clinical Severity Score (VCSS). Power analyses are conducted for anatomical success and post-procedural pain.Both groups will be evaluated on an intention-to-treat principle. The hypothesis of the MESSI trial is that the anatomic success rate of MOCA™ is not inferior to RFA. The second hypothesis is that post-procedural pain is significantly less after MOCA compared to RFA. NTR4613 Date of trial registration: 28 May 2014.
Scordalakes, Constantine; delRosario, Robert; Shimer, Andrew; Stankiewicz, Russell
2018-01-01
Compare amenorrhea rate, menstrual symptoms, patient satisfaction, and adverse events in women who underwent endometrial ablation with the NovaSure versus the Minerva radiofrequency ablation systems. We surveyed 189 premenopausal women (mean 40.8±6.2 years old) who underwent endometrial ablation for abnormal uterine bleeding using the NovaSure (n=97) or Minerva (n=92) systems, at four private US gynecology clinics, and whose procedure date was after July 2015 with follow-up ≥3 months. Women were surveyed an average of 11.3±3.9 months (range 137-532 days) after ablation. The subject-reported amenorrhea rate was 52% higher in NovaSure subjects than Minerva subjects (64% and 42%, respectively; p =0.004). Age and bleeding cyclicity did not affect amenorrhea rate in either group. Normal-to-no bleeding was reported by >90% of subjects after either treatment. NovaSure was significantly more effective than Minerva at reducing pad/tampon use in women with any residual bleeding (2.4±5.2 items/day versus 4.7±5.5 items/day, p =0.049). NovaSure was significantly more effective than Minerva at reducing premenstrual syndrome (PMS) symptoms ( p =0.019) and menstrual pain ( p =0.003), and more NovaSure subjects (94%) than Minerva subjects (78%) were satisfied with clinical outcomes ( p =0.003). Adverse events did not differ by treatment; three women in each group progressed to hysterectomy. While overall bleeding reduction in premenopausal women with abnormal uterine bleeding was excellent with either endometrial ablation system, NovaSure treatment resulted in a higher patient-reported 1-year amenorrhea rate, and women with residual bleeding used fewer pads and tampons than Minerva-treated women. Additionally, NovaSure subjects reported better menstrual-related life quality and PMS symptom alleviation, and greater satisfaction with outcomes than Minerva-treated women.
Frangos, Savvas; Iakovou, Ioannis P; Marlowe, Robert J; Eftychiou, Nicolaos; Patsali, Loukia; Vanezi, Anna; Savva, Androulla; Mpalaris, Vassilis; Giannoula, Evanthia I
2017-02-01
Typically formulated by investigators from "world centres of excellence," differentiated thyroid carcinoma (DTC) management guidelines may have more limited applicability in settings of less expert care and fewer resources. Arguably the world's leading DTC guidelines are those of the American Thyroid Association, revised in 2009 ("ATA 2009") and 2015 ("ATA 2015"). To further explore the issue of "real-world applicability" of DTC guidelines, we retrospectively compared indications for ablation using ATA 2015 versus ATA 2009 in a two-centre cohort of ablated T1-2, M0 DTC patients (N = 336). Based on TNM status and histology, these patients were low-intermediate risk, but many ultimately had other characteristics suggesting elevated or uncertain risk. Working by consensus, two experienced nuclear medicine physicians considered patient and treatment characteristics to classify each case as having "no indication," a "possible indication," or a "clear indication" for ablation according to ATA 2009 or ATA 2015. The physicians also identified reasons for classification changes between ATA 2015 versus ATA 2009. Classification was unblinded, but the physicians had cared for only 138/336 patients, and the charts encompassed September 2010-October 2013, several years before the classification was performed. One hundred of 336 patients (29.8 %) changed classification regarding indication for ablation using ATA 2015 versus ATA 2009. Most reclassified patients (70/100) moved from "no indication" or "clear indication" to "possible indication." Reflecting this phenomenon, "possible indication" became the largest category according to the ATA 2015 classification (141/336, 42.0 %, versus 96/336, 28.6 %, according to ATA 2009). Many reclassifications were attributable to multiple clinicopathological characteristics, most commonly, stimulated thyroglobulin or anti-thyroglobulin antibody levels, multifocality, bilateral involvement, or capsular/nodal invasion. Regarding indications for ablation, ATA 2015 appears to better "acknowledge grey areas," i.e., patients with ambiguous or unavailable data requiring individualised, nuanced decision-making, than does ATA 2009.
Al-Qahtani, Khalid Hussain; Al Asiri, Mushabbab; Tunio, Mutahir A; Aljohani, Naji J; Bayoumi, Yasser; Fatani, Hanadi; AlHadab, Abdulrehman
2015-12-01
Papillary Microcarcinoma (PMC) of thyroid is a rare type of differentiated thyroid cancer (DTC), which according to the World Health Organization measures 1.0 cm or less. The gold standard of treatment of PMC is still controversy. Our aim was to contribute in resolving the debate on the therapeutic choices of the surgical and adjuvant I-131 (RAI) treatment in PMC. From 2000 to 2012, 326 patients were found to have PMC and were retrospectively reviewed for clinicopathological characteristics, treatment outcomes and prognostic factors. Mean age of cohort was 42.6 years (range: 18-76) and the mean tumor size was 0.61 cm ± 0.24; lymph node involvement was seen in 12.9 % of cases. Median follow up period was 8.05 years (1.62-11.4). Total 23 all site recurrences (7.13 %) were observed; more observed in patients without I-131 ablation (p <0.0001). Ten year DFS rates were 89.6 %. Cox regression Model analysis revealed size, histopathologic variants, multifocality, extrathyroidal extension, lymphovascular space invasion, nodal status, and adjuvant RAI ablation the important prognostic factors affecting DFS. Despite excellent DFS rates, a small proportion of patients with PMC develop recurrences after treatment. Adjuvant RAI therapy improves DFS in PMC patients with aggressive histopathologic variants, multifocality, ETE, LVSI, tumor size (> 0.5 cm) and lymph node involvement. Failure of RAI ablation to decrease risk in N1a/b supports prophylactic central neck dissection during thyroidectomy, however more trials are warranted. Adjuvant I-131 ablation following thyroidectomy in PMC patients, particularly with poor prognostic factors improves DFS rates.
Imanli, Hasan; Bhatty, Shaun; Jeudy, Jean; Ghzally, Yousra; Ume, Kiddy; Vunnam, Rama; Itah, Refael; Amit, Mati; Duell, John; See, Vincent; Shorofsky, Stephen; Dickfeld, Timm M
2017-11-01
Visualization of left atrial (LA) anatomy using image integration modules has been associated with decreased radiation exposure and improved procedural outcome when used for guidance of pulmonary vein isolation (PVI) in atrial fibrillation (AF) ablation. We evaluated the CARTOSEG™ CT Segmentation Module (Biosense Webster, Inc.) that offers a new CT-specific semiautomatic reconstruction of the atrial endocardium. The CARTOSEG™ CT Segmentation Module software was assessed prospectively in 80 patients undergoing AF ablation. Using preprocedural contrast-enhanced computed tomography (CE-CT), cardiac chambers, coronary sinus (CS), and esophagus were semiautomatically segmented. Segmentation quality was assessed from 1 (poor) to 4 (excellent). The reconstructed structures were registered with the electroanatomic map (EAM). PVI was performed using the registered 3D images. Semiautomatic reconstruction of the heart chambers was successfully performed in all 80 patients with AF. CE-CT DICOM file import, semiautomatic segmentation of cardiac chambers, esophagus, and CS was performed in 185 ± 105, 18 ± 5, 119 ± 47, and 69 ± 19 seconds, respectively. Average segmentation quality was 3.9 ± 0.2, 3.8 ± 0.3, and 3.8 ± 0.2 for LA, esophagus, and CS, respectively. Registration accuracy between the EAM and CE-CT-derived segmentation was 4.2 ± 0.9 mm. Complications consisted of one perforation (1%) which required pericardiocentesis, one increased pericardial effusion treated conservatively (1%), and one early termination of ablation due to thrombus formation on the ablation sheath without TIA/stroke (1%). All targeted PVs (n = 309) were successfully isolated. The novel CT- CARTOSEG™ CT Segmentation Module enables a rapid and reliable semiautomatic 3D reconstruction of cardiac chambers and adjacent anatomy, which facilitates successful and safe PVI. © 2017 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Oba, Masaki; Miyabe, Masabumi; Akaoka, Katsuaki; Wakaida, Ikuo
2016-02-01
We used laser-induced fluorescence imaging with a varying beam focal point to observe ablation plumes from metal and oxide samples of gadolinium. The plumes expand vertically when the focal point is far from the sample surface. In contrast, the plume becomes hemispherical when the focal point is on the sample surface. In addition, the internal plume structure and the composition of the ablated atomic and ionic particles also vary significantly. The fluorescence intensity of a plume from a metal sample is greater than that from an oxide sample, which suggests that the number of monatomic species produced in each plume differs. For both the metal and oxide samples, the most intense fluorescence from atomic (ionic) species is observed with the beam focal point at 3-4 mm (2 mm) from the sample surface.
Ultrasound-guided peripheral nerve interventions for common pain disorders
Krishna Prasad, B P; Joy, Binu; Raghavendra, Vijayakumar A; Toms, Ajith; George, Danny; Ray, Brijesh
2018-01-01
There are a number of common pain disorders that can be managed effectively by injections around or ablation of peripheral nerves. Ultrasound is a universally available imaging tool, is safe, cost-effective, and is excellent in imaging many peripheral nerves and guiding needles to the site of the nerves. This article aims to present an overview of indications and techniques of such procedures that can be effectively performed by a radiologist. PMID:29692534
NASA Astrophysics Data System (ADS)
Riedo, Andreas; Grimaudo, Valentine; Moreno-García, Pavel; Brigitte Neuland, Maike; Tulej, Marek; Broekmann, Peter; Wurz, Peter
2015-04-01
Sensitive elemental and isotope analysis of solid samples are of considerable interest in nowadays in situ space research. For context in situ analysis, high spatial resolution is also of substantial importance. While the measurements conducted with high lateral resolution can provide compositional details of the surface of highly heterogeneous materials, depth profiling measurements yield information on compositional details of surface and subsurface. The mass spectrometric analysis with the vertical resolution at sub-µm levels is of special consideration and can deliver important information on processes, which may have modified the surface. Information on space weathering effects can be readily determined when the sample composition of the surface and sub-surface is studied with high vertical resolution. In this contribution we will present vertical depth resolution measurements conducted by our sensitive miniature laser ablation ionization time-of-flight mass spectrometer (160mm x Ø 60mm) designed for in situ space research [1-3]. The mass spectrometer is equipped with a fs-laser system (~190fs pulse width, λ = 775nm), which is used for ablation and ionization of the sample material [2]. Laser radiation is focussed on the target material to a spot size of about 10-20 µm in diameter. Mass spectrometric measurements are conducted with a mass resolution (m/Δm) of about 400-500 (at 56Fe mass peak) and with a superior dynamic range of more than eight orders of magnitude. The depth profiling performance studies were conducted on 10µm thick Cu films that were deposited by an additive-assisted electrochemical procedure on Si-wafers. The presented measurement study will show that the current instrument prototype is able to conduct quantitative chemical (elemental and isotope) analysis of solids with a vertical resolution at sub-nm level. Contaminants, incorporated by using additives (polymers containing e.g. C, N, O, S) and with layer thickness of a few nanometres, can be fully resolved [1]. The current measurement performance, including the sensitivity and the high vertical depth resolution, opens new perspectives for future applications in the laboratory, e.g. measurements of Genesis samples, and new measurement capabilities for in situ space research. References 1)V. Grimaudo, P. Moreno-García, M.B. Neuland, M. Tulej, P. Broekmann, P. Wurz and A. Riedo, "High-resolution chemical depth profiling of solid material using a miniature laser ablation/ionization mass spectrometer", Anal. Chem., 2015, submitted. 2)A. Riedo, M. Neuland, S. Meyer, M. Tulej, and P. Wurz, "Coupling of LMS with a fs-laser ablation ion source: elemental and isotope composition measurements", J. Anal. At. Spectrom., 2013, 28, 1256. 3)Tulej et al. CAMAM: A Miniature Laser Ablation Ionisation Mass Spectrometer and Microscope-Camera System for In Situ Investigation of the Composition and Morphology of Extraterrestrial Materials, Geostand. Geoanal. Res., 2014, doi: 10.1111/j.1751-908X.2014.00302.x
Spectral analysis of meteorites ablated in a wind tunnel
NASA Astrophysics Data System (ADS)
Drouard, A.; Vernazza, P.; Loehle, S.; Gattacceca, J.; Zander, T.; Eberhart, M.; Meindl, A.; Oefele, R.; Vaubaillon, J.; Colas, F.
2017-09-01
Recently and for the very first time, experiments simulating vaporization of a meteorite sample were performed in a wind tunnel near Stuttgart with the specific aim to record emission spectra of the vaporized material. Using a high enthalpy air plasma flow for modeling an equivalent air friction of an entry speed of about 10 km/s, three meteorite types (H, CM and HED) and two meteoritical analogues (basalt and argillite) were ablated and high resolution spectra were recorded simultaneously. After the identification of all atomic lines, we per- formed a detailed study of our spectra using two approaches: (i) by direct comparison of multiplet in- tensities between the samples and (ii) by computation of a synthetic spectrum to constrain some physical parameters (temperature, elemental abundance). Finally, we compared our results to the elemental composition of our samples and we determined how much compositional information can be retrieved for a given meteor using visible sectroscopy.
NASA Technical Reports Server (NTRS)
Desai, Tapan G.; Lawson, John W.; Keblinski, Pawel
2010-01-01
Reactive molecular dynamics simulations are used to study initial stage of pyrolysis of ablation materials and their composites with carbon nanotubes and carbon fibers. The products formed during pyrolysis are characterized and water is found as the primary product in all cases. The water formation mechanisms are analyzed and the value of the activation energy for water formation is estimated. A detailed study on graphitic precursor formation reveals the presence of two temperature zones. In the lower temperature zone (less than 2000 K) polymerization occurs resulting in formation of large, stable graphitic precursors, and in the high temperature zone (greater than 2000 K) polymer scission results in formation of short polymer chains/molecules. Simulations performed in the high temperature zone on the phenolic resin composites (with carbon nanotubes and carbon fibers) shows that the presence of interfaces had no substantial effect on the chain scission rate or the activation energy value for water formation.
ARO - Terrestrial Research Program, Methodologies and Protocols for Characterization of Geomaterials
2015-05-14
of ice involves melting, digestion, and analysis using inductively coupled plasma – mass spectrometry (ICPMS). ICP-MS analysis established elemental...4] have distinct chemical compositions. Knowledge of the chemical composition of the mineral assemblage present in a rock is critical to...activation analysis (INAA), to inductively-coupled plasma analysis and mass spectrometry (ICP & ICP-MS), mass spectrometry (MS), and laser-ablation
Nd Isotope and U-Th-Pb Age Mapping of Single Monazite Grains by Laser Ablation Split Stream Analysis
NASA Astrophysics Data System (ADS)
Fisher, C. M.; Hanchar, J. M.; Miller, C. F.; Phillips, S.; Vervoort, J. D.; Martin, W.
2015-12-01
Monazite is a common accessory mineral that occurs in medium to high grade metamorphic and Ca-poor felsic igneous rocks, and often controls the LREE budget (including Sm and Nd) of the host rock in which it crystallizes. Moreover, it contains appreciable U and Th, making it an ideal mineral for determining U-Th-Pb ages and Sm-Nd isotopic compositions, both of which are readily determined using in situ techniques with very high spatial resolution like LA-MC-ICPMS. Here, we present the results of laser ablation split stream analyses (LASS), which allows for simultaneous determination of the age and initial Nd isotopic composition in a single analysis. Analyses were done using a 20mm laser spot that allowed for detailed Nd isotope mapping of monazite grains (~30 analyses per ~250mm sized grain). Combined with LREE ratios (e.g., Sm/Nd, Ce/Gd, and Eu anomalies) these results yield important petrogenetic constraints on the evolution of peraluminous granites from the Old Woman-Piute batholith in southeastern California. Our findings also allow an improved understanding of the causes of isotope heterogeneity in granitic rocks. U-Th-Pb age mapping across the crystals reveals a single Cretaceous age for all grains with precision and accuracy typical of laser ablation analyses (~2%). In contrast, the concurrent Nd isotope mapping yields homogeneous initial Nd isotope compositions for some grains and large initial intra-grain variations of up to 8 epsilon units in others. The grains that yield homogeneous Nd isotope compositions have REE ratios suggesting that they crystallized in a fractionally crystallizing magma. Conversely, other grains, which also record fractional crystallization of both feldspar and LREE rich minerals, demonstrate a change in the Nd isotope composition of the magma during crystallization of monazite. Comparison of inter- and intra-grain Nd isotope compositions reveals further details on the potential mechanisms responsible for isotope heterogeneity present in single rock samples. This method highlights the potential of single grain isotope mapping of LREE phases such as monazite, allanite, and titanite for understanding both igneous and metamorphic petrogenesis.
Barret, Juan P
2014-01-01
The innovation of composite vascularized allotransplantation has provided plastic and reconstructive surgeons with the ultimate tool for those patients that present with facial deformities that cannot be reconstructed with classical or more traditional techniques. Transplanting normal tissues allows for a true restorative surgery. Initial experiences included the substitution of missing anatomy, whereas after the first world's full-face transplant performed in Barcelona in March 2010, a true ablative surgery with a total restoration proved to be effective. We review the world's experience and the performance of our restorative protocol to depict this change in the reconstructive paradigm of facial transplantation. Facial transplants should be performed after a careful analysis of the defect, with a comprehensive ablation plan following esthetic units with sacrifice of all required tissues with a focus of global restoration of anatomy, aesthetics and function, respecting normal functioning muscles. Nowadays, facial transplants following strict esthetic units should restore disfigurement extending to small central areas, whereas major defects may require a total ablation and restoration with full-face transplants. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Femtosecond ablation applied to deep-drilling of hard metals
NASA Astrophysics Data System (ADS)
Bruneau, Sebastien; Hermann, Joerg; Dumitru, Gabriel; Sentis, Marc L.
2004-09-01
Mechanisms responsible for the limitation of the aspect ratio obtained by deep drilling of hard metals are investigated in the present work. Cemented carbide targets have been irradiated with laser pulses of 100 fs duration and 100 μJ maximum energy delivered by a Ti:sapphire laser system. The experiments are carried out in different gas environments (vacuum, air, helium up to atmospheric pressure) with incident laser fluences ranging from 1 to 20 Jcm-2. During deep drilling, the laser-induced ablation plume is characterized by means of in-situ plasma diagnostics. Fast imaging is used to observe the expansion behavior of the plasma plume whereas time- and space-resolved emission spectroscopy is employed to analyze the plasma composition. After irradiation, the laser-produced craters were examined by optical microscopy. A correlation between the ablation plume characteristics and the morphological changes of the mciro-holes is established. The results indicate that nanoclusters, that present a significant part of the ablated material, are responsbile for the alteration of the crater shape in the high laser fluence regime.
Tiong, Leong U; Finnie, John W; Field, John B; Maddern, Guy J
2012-07-01
In bimodal electric tissue ablation (BETA), the cathode of the DC circuit is attached to the radiofrequency (RF) electrode to increase the surrounding tissue hydration. This will delay tissue desiccation and allowing the ablation process to continue for a longer period of time before "roll-off" occurs, resulting in larger ablations compared with standard radiofrequency ablation (RFA). Previous research showed that attaching the anode to the skin using electrosurgical grounding pads would reduce the efficacy of BETA because of the high electrical resistivity of the skin. This study investigated the ablation size produced when the anode was attached to the peritoneum (BETA-peritoneum) and the liver (BETA-liver) respectively. The anode of the DC circuit in BETA was attached to the peritoneum and the liver in a pig model using ECG dots. In BETA, 9 V of DC was provided for 10 min, after which the radiofrequency generator were switched on and both electrical circuits allowed to run concurrently until "roll-off." The size of ablations produced was compared to when the anode attached to the skin (BETA-skin) and standard RFA, respectively. The sites of anode placement were examined for local tissue injury. The transverse diameters in BETA-peritoneum and BETA-liver were significantly larger compared with BETA-skin and standard RFA, respectively (P < 0.001). The axial diameter in the BETA-peritoneum and BETA-liver groups were also larger compared with the BETA-skin and RFA groups, although the differences did not reach statistical significance (P = 0.09). Hematoxylin and eosin (H and E) examination of the peritoneum and the liver where the anode was attached showed coagulation necrosis involving the superficial epithelium and the liver capsule, respectively. BETA can be used to treat larger liver tumors more effectively and may reduce the tumor recurrence rates compared with standard RFA. The efficacy of BETA depends on ensuring good electrical conductivity between the cathode and the anode of the DC circuit. Research so far has shown that BETA works best when the anode is placed deep to the skin as the stratum corneum consisted of a layer of a-nucleated cells, which have high electrical resistivity. The liver could be the ideal location to place the anode as it has excellent electrical conductivity, therefore ensuring maximum tissue hydration around the cathode to produce the largest ablations possible. Copyright © 2012 Elsevier Inc. All rights reserved.
Buy, Xavier; Tok, Chung-Hong; Szwarc, Daniel; Bierry, Guillaume; Gangi, Afshin
2009-05-01
Percutaneous image-guided thermal ablation of tumor is widely used, and thermal injury to collateral structures is a known complication of this technique. To avoid thermal damage to surrounding structures, several protection techniques have been reported. We report the use of a simple and effective protective technique combining carbon dioxide dissection and thermocouple: CO(2) displaces the nontarget structures, and its low thermal conductivity provides excellent insulation; insertion of a thermocouple in contact with vulnerable structures achieves continuous thermal monitoring. We performed percutaneous thermal ablation of 37 tumors in 35 patients (4 laser, 10 radiofrequency, and 23 cryoablations) with protection of adjacent vulnerable structures by using CO(2) dissection combined with continuous thermal monitoring with thermocouple. Tumor locations were various (19 intra-abdominal tumors including 4 livers and 9 kidneys, 18 musculoskeletal tumors including 11 spinal tumors). CO(2) volume ranged from 10 ml (epidural space) to 1500 ml (abdominal). Repeated insufflations were performed if necessary, depending on the information given by the thermocouple and imaging control. Dissection with optimal thermal protection was achieved in all cases except two patients where adherences (one postoperative, one arachnoiditis) blocked proper gaseous distribution. No complication referred to this technique was noted. This safe, cost-effective, and simple method increases the safety and the success rate of percutaneous thermal ablation procedures. It also offers the potential to increase the number of tumors that can be treated via a percutaneous approach.
Preparation and testing of nickel-based superalloy/sodium heat pipes
NASA Astrophysics Data System (ADS)
Lu, Qin; Han, Haitao; Hu, Longfei; Chen, Siyuan; Yu, Jijun; Ai, Bangcheng
2017-11-01
In this work, a kind of uni-piece nickel-based superalloy/sodium heat pipe is proposed. Five models of high temperature heat pipe were prepared using GH3044 and GH4099 nickel-based superalloys. And their startup performance and ablation resistance were investigated by quartz lamp calorifier radiation and wind tunnel tests, respectively. It is found that the amount of charging sodium affects the startup performance of heat pipes apparently. No startup phenomenon was found for insufficient sodium charged model. In contrast, the models charged with sufficient sodium startup successfully, displaying a uniform temperature distribution. During wind tunnel test, the corresponding models experienced a shorter startup time than that during quartz lamp heating. GH4099/sodium heat pipe shows excellent ablation resistance, being better than that of GH3044/sodium heat pipe. Therefore, it is proposed that this kind of heat pipe has a potential application in thermal protection system of hypersonic cruise vehicles.
NASA Astrophysics Data System (ADS)
Lin, Jun; Pakhomov, Andrew V.
2005-04-01
This work concludes our discussion of the image processing technique developed earlier for determination of specific impulse (Isp) for Ablative Laser Propulsion (ALP). The plasma plumes are recorded with a time-resolved intensified charge-coupled device (ICCD) camera. The plasma was formed in vacuum (˜ 3×10-3 Torr) by focusing output pulses of a laser system (100-ps pulsewidth at 532 nm wavelength and ˜35 mJ energy) on surfaces of C (graphite), Al, Si, Fe, Cu, Zn, Sn, and Pb elements. Angular profiles for integrated intensity and plasma expansion velocity were determined for the tested elements. Such profiles were used further for assessment of specific impulse. Specific impulses derived from angular distributions of plasma expansion velocity and integral intensity appeared in excellent agreement with the data derived earlier from force measurements.
Analysis of fabric materials cut using ultraviolet laser ablation
NASA Astrophysics Data System (ADS)
Tsai, Hsin-Yi; Yang, Chih-Chung; Hsiao, Wen-Tse; Huang, Kuo-Cheng; Andrew Yeh, J.
2016-04-01
Laser ablation technology has widely been applied in the clothing industry in recent years. However, the laser mechanism would affect the quality of fabric contours and its components. Hence, this study examined carbonization and oxidation conditions and contour variation in nonwoven, cotton, and composite leather fabrics cut by using an ultraviolet laser at a wavelength of 355 nm. Processing parameters such as laser power, pulse frequency, scanning speed, and number of pulses per spot were adjusted to investigate component variation of the materials and to determine suitable cutting parameters for the fabrics. The experimental results showed that the weights of the component changed substantially by pulse frequency but slightly by laser power, so pulse frequency of 100 kHz and laser power of 14 W were the approximate parameters for three fabrics for the smaller carbonization and a sufficient energy for rapidly cutting, which the pulse duration of laser system was fixed at 300 μs and laser irradiance was 0.98 J/mm2 simultaneously. In addition, the etiolate phenomenon of nonwoven was reduced, and the component weight of cotton and composite leather was closed to the value of knife-cut fabric as the scanning speed increased. The approximate scanning speed for nonwoven and composite leather was 200 mm/s, and one for cotton was 150 mm/s, respectively. The sharper and firmer edge is obtained by laser ablation mechanism in comparison with traditional knife cutting. Experimental results can serve as the reference for laser cutting in the clothing industry, for rapidly providing smoother patterns with lower carbonization and oxidation edge in the fashion industry.
High temperature ablative foam
NASA Technical Reports Server (NTRS)
Liu, Matthew T. (Inventor)
1992-01-01
An ablative foam composition is formed of approximately 150 to 250 parts by weight polymeric isocyanate having an isocyanate functionality of 2.6 to 3.2; approximately 15 to 30 parts by weight reactive flame retardant having a hydroxyl number range from 200-260; approximately 10 to 40 parts by weight non-reactive flame retardant; approximately 10 to 40 parts by weight nonhydrolyzable silicone copolymer having a hydroxyl number range from 75-205; and approximately 3 to 16 parts by weight amine initiated polyether resin having an isocyanate functionality greater than or equal to 3.0 and a hydroxyl number range from 400-800.
Chen, Kai-Yun; Fan, Chao; Yuan, Hong-Lin; Bao, Zhi-An; Zong, Chun-Lei; Dai, Meng-Ning; Ling, Xue; Yang, Ying
2013-05-01
In the present study we set up a femtosecond laser ablation MC-ICP-MS method for lead isotopic analysis. Pb isotopic composition of fifteen copper (brass, bronze) standard samples from the National Institute of Standards Material were analyzed using the solution method (MC-ICP-MS) and laser method (fLA-MC-ICPMS) respectively, the results showed that the Pb isotopic composition in CuPb12 (GBW02137) is very homogeneous, and can be used as external reference material for Pb isotopic in situ analysis. On CuPb12 112 fLA-MC-ICPMS Pb isotope analysis, the weighted average values of the Pb isotopic ratio are in good agreement with the results analyzed by bulk solution method within 2sigma error, the internal precision RSEs of the 208 Pb/204 Pb ratio and 207 Pb/206 Pb ratio are less than 90 and 40 ppm respectively, and the external precision RSDs of them are less than 60 and 30 ppm respectively. Pb isotope of thirteen ancient bronze coins was analyzed via fLA-MC-ICPMS, the results showed that the Pb isotopic composition of ancient coins of different dynasties is significantly different, and not all the Pb isotopic compositions in the coins even from the same dynasty are in agreement with each other.
Blandino, Alessandro; Bianchi, Francesca; Biondi-Zoccai, Giuseppe; Grossi, Stefano; Conte, Maria Rosa; Rametta, Francesco; Gaita, Fiorenzo
2016-09-01
Apixaban, a direct factor Xa inhibitor recently approved for thromboembolic prophylaxis in patients with nonvalvular atrial fibrillation (AF), is increasingly used in patients undergoing catheter ablation of AF. However, large randomized studies supporting its use in the ablation context are still lacking. We undertook the present meta-analysis to assess the impact of apixaban in terms of thromboembolic and bleeding events in patients undergoing AF ablation as compared to warfarin. MEDLINE/PubMed, Cochrane Library, and references reporting AF ablation and apixaban were screened and studies included if matching inclusion and exclusion criteria. One randomized and five nonrandomized studies were included in the analysis. Patients enrolled were 1691 patients (668 on apixaban and 1023 on warfarin). There was no heterogeneity in all the outcome comparisons. No deaths were reported. We did not observe any difference between apixaban and warfarin with respect to thromboembolic events (OR = 1.10, 95 % CI 0.24-5.16), major bleedings (OR = 1.56, 95 % CI 0.59-4.13), cardiac tamponade (OR 1.69, 95 % CI 0.52-5.54), minor bleedings (OR 0.96, 95 % CI 0.58-1.59), and the composite endpoint of death, thromboembolic events, and bleedings (OR 1.03, 95 % CI 0.65-1.64). The rates of death, thromboembolic events, major bleedings including cardiac tamponade, and minor bleedings in patients on apixaban undergoing AF ablation are very low and similar to that seen in patients treated with uninterrupted warfarin. Although primary driven by nonrandomized studies, these results support apixaban as periprocedural anticoagulation during AF ablation procedures.
[INVITED] Control of femtosecond pulsed laser ablation and deposition by temporal pulse shaping
NASA Astrophysics Data System (ADS)
Garrelie, Florence; Bourquard, Florent; Loir, Anne--Sophie; Donnet, Christophe; Colombier, Jean-Philippe
2016-04-01
This study explores the effects of temporal laser pulse shaping on femtosecond pulsed laser deposition (PLD). The potential of laser pulses temporally tailored on ultrafast time scales is used to control the expansion and the excitation degree of ablation products including atomic species and nanoparticles. The ablation plume generated by temporally shaped femtosecond pulsed laser ablation of aluminum and graphite targets is studied by in situ optical diagnostic methods. Taking advantage of automated pulse shaping techniques, an adaptive procedure based on spectroscopic feedback regulates the irradiance for the enhancement of typical plasma features. Thin films elaborated by unshaped femtosecond laser pulses and by optimized sequence indicate that the nanoparticles generation efficiency is strongly influenced by the temporal shaping of the laser irradiation. The ablation processes leading either to the generation of the nanoparticles either to the formation of plasma can be favored by using a temporal shaping of the laser pulse. Insights are given on the possibility to control the quantity of the nanoparticles. The temporal laser pulse shaping is shown also to strongly modify the laser-induced plasma contents and kinetics for graphite ablation. Temporal pulse shaping proves its capability to reduce the number of slow radicals while increasing the proportion of monomers, with the addition of ionized species in front of the plume. This modification of the composition and kinetics of plumes in graphite ablation using temporal laser pulse shaping is discussed in terms of modification of the structural properties of deposited Diamond-Like Carbon films (DLC). This gives rise to a better understanding of the growth processes involved in femtosecond-PLD and picosecond-PLD of DLC suggesting the importance of neutral C atoms, which are responsible for the subplantation process.
[Clinical use of interventional MR imaging].
Kahn, Thomas; Schulz, Thomas; Moche, Michael; Prothmann, Sascha; Schneider, Jens-Peter
2003-01-01
The integration of diagnostic and therapeutic procedures by MRI is based on the combination of excellent morphologic and functional imaging. The spectrum of MR-guided interventions includes biopsies, thermal ablation procedures, vascular applications, and intraoperative MRI. In all these applications, different scientific groups have obtained convincing results in basic developments as well as in clinical use. Interventional MRI (iMRI) is expected to attain an important role in interventional radiology, minimal invasive therapy, and monitoring of surgical procedures.
Self-limiting and complete oxidation of silicon nanostructures produced by laser ablation in water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vaccaro, L.; Messina, F.; Camarda, P.
2016-07-14
Oxidized Silicon nanomaterials produced by 1064 nm pulsed laser ablation in deionized water are investigated. High-resolution transmission electron microscopy coupled with energy dispersive X-ray spectroscopy allows to characterize the structural and chemical properties at a sub-nanometric scale. This analysis clarifies that laser ablation induces both self-limiting and complete oxidation processes which produce polycrystalline Si surrounded by a layer of SiO{sub 2} and amorphous fully oxidized SiO{sub 2}, respectively. These nanostructures exhibit a composite luminescence spectrum which is investigated by time-resolved spectroscopy with a tunable laser excitation. The origin of the observed luminescence bands agrees with the two structural typologies: Si nanocrystalsmore » emit a μs-decaying red band; defects of SiO{sub 2} give rise to a ns-decaying UV band and two overlapping blue bands with lifetime in the ns and ms timescale.« less
Impact of solvent mixture on iron nanoparticles generated by laser ablation
NASA Astrophysics Data System (ADS)
Chakif, M.; Prymak, O.; Slota, M.; Heintze, E.; Gurevich, E. L.; Esen, C.; Bogani, L.; Epple, M.; Ostendorf, A.
2014-03-01
The present work reveals the structural and magnetic properties of iron oxide (FexOy) nanoparticles (NPs) prepared by femtosecond laser ablation. The FexOy-NPs were produced in solutions consisting of different ratios of water and acetone. Laser ablation in water yields agglomerates and that in acetone yields chain structures whereas that in water/acetone show a mixture of both. We observe significant fabrication dependent properties such as different crystallinities and magnetic behaviors. The structural characterization shows a change from iron (Fe) to a FexOy state of the NPs which depends on the solution composition. Furthermore, transmission electron microscopy measurements exhibit a broad particle size distribution in all samples but with significant differences in the mean sizes. Using magnetic measurements we show that nanoparticles fabricated in pure acetone have lower coercive fields which come along with a smaller mean particle size and therefore increasing superparamagnetic behavior.
NASA Astrophysics Data System (ADS)
Nguyen, Daniel; Staninec, Michal; Lee, Chulsung; Fried, Daniel
2010-02-01
A mechanically scanned CO2 laser operated at high laser pulse repetition rates can be used to rapidly and precisely remove dental decay. This study aims to determine whether these laser systems can safely ablate enamel and dentin without excessive heat accumulation and peripheral thermal damage. Peripheral thermal damage can adversely impact the mechanical strength of the irradiated tissue, particularly for dentin, and reduce the adhesion characteristics of the modified surfaces. Samples were derived from noncarious extracted molars. Pulpal temperatures were recorded using microthermocouples situated at the pulp chamber roof of samples (n=12), which were occlusally ablated using a rapid-scanning, water-cooled 300 Hz CO2 laser over a two minute time course. The mechanical strength of facially ablated dentin (n=10) was determined via four-point bend test and compared to control samples (n=10) prepared with 320 grit wet sand paper to simulate conventional preparations. Composite-to-enamel bond strength was measured via single-plane shear test for ablated/non-etched (n=10) and ablated/acid-etched (n=8) samples and compared to control samples (n=9) prepared by 320 grit wet sanding. Thermocouple measurements indicated that the temperature remained below ambient temperature at 19.0°C (s.d.=0.9) if water-cooling was used. There was no discoloration of either dentin and enamel, the treated surfaces were uniformly ablated and there were no cracks observable on the laser treated surfaces. Fourpoint bend tests yielded mean mechanical strengths of 18.2 N (s.d.=4.6) for ablated dentin and 18.1 N (s.d.=2.7) for control (p>0.05). Shear tests yielded mean bond strengths of 31.2 MPa (s.d.=2.5, p<0.01) for ablated/acid-etched samples, 5.2 MPa (s.d.=2.4, p<0.001) for ablated/non-etched samples, and 37.0 MPa (s.d.=3.6) for control. The results indicate that a rapid-scanning 300 Hz CO2 laser can effectively ablate dentin and enamel without excessive heat accumulation and with minimal thermal damage. It is not clear whether the small (16%) but statistically significant reduction in the shear bond strength to enamel is clinically significant since the mean shear bond strength exceeded 30 MPa.
Future requirements for advanced materials
NASA Technical Reports Server (NTRS)
Olstad, W. B.
1980-01-01
Recent advances and future trends in aerospace materials technology are reviewed with reference to metal alloys, high-temperature composites and adhesives, tungsten fiber-reinforced superalloys, hybrid materials, ceramics, new ablative materials, such as carbon-carbon composite and silica tiles used in the Shuttle Orbiter. The technologies of powder metallurgy coupled with hot isostatic pressing, near net forging, complex large shape casting, chopped fiber molding, superplastic forming, and computer-aided design and manufacture are emphasized.
Castagna, Maria Grazia; Pinchera, Aldo; Marsili, Alessandro; Giannetti, Monica; Molinaro, Eleonora; Fierabracci, Paola; Grasso, Lucia; Pacini, Furio; Santini, Ferruccio; Elisei, Rossella
2005-07-01
In this study, we evaluated the influence of height, weight, body mass index (BMI), body surface area, and body composition [total lean body mass (LBM) and fat body mass] on serum peak TSH levels obtained after recombinant human (rh)TSH. Furthermore, to verify whether the serum peak TSH influenced the efficacy of radioiodine ((131)I), we compared the rate of thyroid remnant ablation according to the patients' BMI. We studied 105 patients with differentiated thyroid carcinoma who underwent rhTSH stimulation test. Serum TSH measurements were performed before and 24, 48, and 72 h after rhTSH administration. We also compared the rate of thyroid remnant ablation among 70 differentiated thyroid carcinoma patients with different BMI. The serum peak TSH after rhTSH was significantly lower in overweight and obese subjects compared with normal-weight subjects (92.1 +/- 41.8, 82.4 +/- 24.2, and 112.7 +/- 46.3 microU/ml, respectively; P = 0.01) and in males compared with females (74.6 +/- 22.3 and 105.0 +/- 43.0 microU/ml, respectively; P = 0.0002). By univariate analysis, serum peak TSH was negatively related to weight, height, body surface area, BMI, LBM, and fat body mass, but only LBM was independently associated with serum peak TSH levels. Although it was confirmed that overweight and obese patients had a lower serum peak TSH, the rate of ablation did not differ among normal-weight, overweight, and obese patients. With this study we demonstrated that LBM is the only parameter independently associated with serum peak TSH after rhTSH administration. However, the serum peak TSH does not influence the rate of (131)I remnant ablation.
NASA Astrophysics Data System (ADS)
Brigitte Neuland, Maike; Mezger, Klaus; Tulej, Marek; Frey, Samira; Riedo, Andreas; Wurz, Peter; Wiesendanger, Reto
2017-04-01
The knowledge of the chemical composition of moons, comets, asteroids or other planetary bodies is of particular importance for the investigation of the origin and evolution of the Solar System. High resolution in situ studies on planetary surfaces can yield important information on surface heterogeneity, basic grain mineralogy and chemical composition of surface and subsurface. In turn, these data are the basis for our understanding of the physical and chemical processes which led to the formation and alteration of planetary material [1]. We investigated samples of Allende and Sayh al Uhaymir with a highly miniaturised laser mass spectrometer (LMS), which has been designed and built for in situ space research [2,3]. Both meteorite samples were investigated with a spatial resolution of about 10μm in lateral direction. The high sensitivity and high dynamic range of the LMS allow for quantitative measurements of the abundances of the rock-forming and minor and trace elements with high accuracy [4]. From the data, the modal mineralogy of micrometre-sized chondrules can be inferred [5], conclusions about the condensation sequence of the material are possible and the sensitivity for radiogenic elements allows for dating analyses of the investigated material. We measured the composition of various chondrules in Allende, offering valuable clues about the condensation sequence of the different components of the meteorite. We explicitly investigated the chemical composition and heterogeneity of the Allende matrix with an accuracy that cannot be reached by the mechanical analysis methods that were and are widely used in meteoritic research. We demonstrate the capabilities for dating analyses with the LMS. By applying the U-Th-dating method, the age of the SaU169 sample could be determined. Our analyses show that the LMS would be a suitable instrument for high-quality quantitative chemical composition measurements on the surface of a celestial body like a planet, moon or asteroid. [1] Wurz, P., Whitby, J., Managadze, G. , "Laser Mass Spectrometry in Planetary Science", AIP Conf.Proc. CP1144(2009): 70-75. [2] Rohner, U., Whitby, J.A. and Wurz, P. "A miniature laser ablation time-of-flight mass spectrometer for in situ planetary exploration", Measurement Science and Technology 14 (2003): 2159-2164. [3] Riedo, A., Bieler, A., Neuland, M., Tulej, M. and Wurz, P., "Performance evaluation of a miniature laser ablation time-of-flight mass spectrometer designed for in situ investigations in planetary space research", Journal of Mass Spectrometry 48 (2013): 1 -15 [4] Neuland, M.B., Grimaudo, V., Mezger, K., Moreno-García, P., Riedo, A., Tulej, M. and Wurz, P., "Quantitative measurement of the chemical composition of geological standards with a miniature laser ablation/ionisation mass spectrometer designed for in situ application in space research", Meas. Sci. Technol. 27(2016), article ID:035904, 1 - 13. [5] Tulej, M., Neubeck, A., Ivarsson, M., Riedo, A., Neuland, M.B., Meyer, S. and Wurz, P., "Chemical composition of micrometer-sized filaments in an aragonite host by a miniature laser ablation/ionization mass spectrometer", Astrobiol., 15 (2015): 669 - 682.
NASA Astrophysics Data System (ADS)
Tsunemi, Akira; Endo, Akira; Ichishima, Daiji
1998-09-01
A high power TEA CO2 laser was applied to strip paints from the surface of aircraft. For our experimental samples, aluminum and fiber-reinforced composite substrate were painted as the completely same way as normal aircraft. As a result of delicate control of the irradiation parameters, the surfaces of not only aluminum substrate but also composite substrate were clearly exposed without any damages. Removed materials were found out to be effectively collected by a combination of a micro filter and activated carbon powder.
Thermoplastic polymides and composites therefrom
NASA Technical Reports Server (NTRS)
Harris, Frank W. (Inventor)
1994-01-01
A new class polyimide and polyimide precursors based on diaryl oxyalkylene diamines, such as 1,3-bis[4-aminophenoxy]-2,2-dimethyl propane, a process for their preparation and their use as the continuous phase for the manufacture of composites and composite laminates reinforced by reinforcing agents such as carbon fibers, Kevlar.TM., and other similar high strength reinforcing agents. The polyimides and molecular composites obtained from the diamines according to the invention show thermoplastic properties, excellent flex fatigue and fracture resistance, and excellent thermal and oxidative stability.
A rotational ablation tool for calcified atherosclerotic plaque removal.
Kim, Min-Hyeng; Kim, Hyung-Jung; Kim, Nicholas N; Yoon, Hae-Sung; Ahn, Sung-Hoon
2011-12-01
Atherosclerosis is a major cardiovascular disease involving accumulations of lipids, white blood cells, and other materials on the inside of artery walls. Since the calcification found in the advanced stage of atherosclerosis dramatically enhances the mechanical properties of the plaque, restoring the original lumen of the artery remains a challenge. High-speed rotational atherectomy, when performed with an ablating grinder to remove the plaque, produces much better results in the treatment of calcified plaque compared to other methods. However, the high-speed rotation of the Rotablator commercial rotational atherectomy device produces microcavitation, which should be avoided because of the serious complications it can cause. This research involves the development of a high-speed rotational ablation tool that does not generate microcavitation. It relies on surface modification to achieve the required surface roughness. The surface roughness of the tool for differential cutting was designed based on lubrication theory, and the surface of the tool was modified using Nd:YAG laser beam engraving. Electron microscope images and profiles indicated that the engraved surface of the tool had approximately 1 μm of root mean square surface roughness. The ablation experiment was performed on hydroxyapatite/polylactide composite with an elastic modulus similar to that of calcified plaque. In addition, differential cutting was verified on silicone rubber with an elastic modulus similar to that of a normal artery. The tool performance and reliability were evaluated by measuring the ablation force exerted, the size of the debris generated during ablation, and through visual inspection of the silicone rubber surface.
2D Superparamagnetic Tantalum Carbide Composite MXenes for Efficient Breast-Cancer Theranostics
Liu, Zhuang; Lin, Han; Zhao, Menglong; Dai, Chen; Zhang, Shengjian; Peng, Weijun; Chen, Yu
2018-01-01
Background: The emergence of two-dimensional MXenes has spurred their versatile applications in broad fields, but the exploring of novel MXene-based family members and their potential applications in theranostic nanomedicine (concurrent diagnostic imaging and therapy) have been rarely explored. In this work, we report the construction of a novel superparamagnetic MXene-based theranostic nanoplatform for efficient breast-cancer theranostics, which was based on intriguing tantalum carbide (Ta4C3) MXene and its further rational surface-superparamagnetic iron-oxide functionalization (Ta4C3-IONP-SPs composite MXenes) for efficient breast-cancer theranostic. Methods: The fabrication of ultrathin Ta4C3 nanosheets was based on an exfoliation strategy and superparamagnetic iron oxide nanoparticles were in-situ grown onto the surface of Ta4C3 MXene according to the redox reaction of MXene. Ta4C3-IONP MXenes were modified with soybean phospholipid (SP) to guarantee high stability in physiological conditions. The photothermal therapy, contrast-enhanced CT, T2-weighted magnetic resonance imaging and the high biocompatibility of these composite nanosheets have also been evaluated in vitro at cellular level and in vivo on mice breast tumor allograft tumor model. Results: The Ta component of Ta4C3-IONP-SPs exhibits high performance for contrast-enhanced CT imaging because of its high atomic number and high X-ray attenuation coefficient, and the integrated superparamagnetic IONPs act as excellent contrast agents for T2-weighted magnetic resonance imaging. Especially, these Ta4C3-IONP-SPs composite nanosheets with high photothermal-conversion efficiency (η: 32.5%) has achieved complete tumor eradication without reoccurrence, verifying their highly efficient breast-tumor photo-ablation performance. Conclusion: This work not only significantly broadens the biomedical applications of MXene-based nanoplatforms (Ta4C3 MXene) by exploring their novel family members and further functionalization strategies (magnetic functionalization in this work), but also provides a novel and efficient theranostic nanoplatform for efficient breast-cancer theranostics. PMID:29556347
Chemical equilibrium of ablation materials including condensed species
NASA Technical Reports Server (NTRS)
Stroud, C. W.; Brinkley, K. L.
1975-01-01
Equilibrium is determined by finding chemical composition with minimum free energy. Method of steepest descent is applied to quadratic representation of free-energy surface. Solution is initiated by selecting arbitrary set of mole fractions, from which point on free-energy surface is computed.
PRK by Er:YAG laser: in-vitro studies and first in-vivo experiences
NASA Astrophysics Data System (ADS)
Steiner, Rudolf W.; Leiacker, Richard; Russ, Detlef; Seiler, Theo
1996-01-01
Photorefractive keratectomy (PRK) is usually performed by an excimer laser at 193 nm wavelength. Ablatio of corneal tissue is, however, not only possible in the UV region of the optical spectrum but also in the IR where water is an excellent absorber. Therefore, an Er:YAG laser was used at 2.94 micrometer wavelength as an alternative laser light source to perform in vitro studies of corneal ablation and also first clinical experiments to correct myopia of patients with blind eyes.
Osseointegration of zirconia implants: an SEM observation of the bone-implant interface.
Depprich, Rita; Zipprich, Holger; Ommerborn, Michelle; Mahn, Eduardo; Lammers, Lydia; Handschel, Jörg; Naujoks, Christian; Wiesmann, Hans-Peter; Kübler, Norbert R; Meyer, Ulrich
2008-11-06
The successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics, biocompatibility, and bright tooth-like color, zirconia (zirconium dioxide, ZrO2) has the potential to become a substitute for titanium as dental implant material. The present study aimed at investigating the osseointegration of zirconia implants with modified ablative surface at an ultrastructural level. A total of 24 zirconia implants with modified ablative surfaces and 24 titanium implants all of similar shape and surface structure were inserted into the tibia of 12 Göttinger minipigs. Block biopsies were harvested 1 week, 4 weeks or 12 weeks (four animals each) after surgery. Scanning electron microscopy (SEM) analysis was performed at the bone implant interface. Remarkable bone attachment was already seen after 1 week which increased further to intimate bone contact after 4 weeks, observed on both zirconia and titanium implant surfaces. After 12 weeks, osseointegration without interposition of an interfacial layer was detected. At the ultrastructural level, there was no obvious difference between the osseointegration of zirconia implants with modified ablative surfaces and titanium implants with a similar surface topography. The results of this study indicate similar osseointegration of zirconia and titanium implants at the ultrastructural level.
NASA Astrophysics Data System (ADS)
Haque, F.; Nahar, N.; Sultana, S.; Nasreen, F.; Jabin, Z.; Alam, A. S. M. M.
2016-03-01
The overall prognosis of patients with thyroid carcinoma is excellent whenever managed following best practice guidelines. Objective: To calculate sex and age group affected by thyroid cancer; to compare between single or multiple dose of radio ablation needed after thyroidectomy and to determine the percentage of patients become disease free during their follow up. Methods: This was a retrospective study done in NINMAS, Bangladesh on 687 patients from 1984 to 2004. In all cases total or near total thyroidectomy was done before commencing radioiodine therapy. Patients TG level, neck ultrasonography, thyroid scan, whole body I131 scans, neck examination were done every six monthly/yearly. Results: Among 687 patients, female were more sufferers (68.1%) and female to male ratio was 2:1. Age group 19-40 years was mostly affected (57.8%). Most common type seen was papillary carcinoma (81.8%). After ablation 100 patients did not follow-up. Total 237 patients discontinued within 4 years. Remaining 450 patients undergone regular follow-up for 5 years and more, 394 were disease free (87.6%). Total recurrence of metastasis was 23 and 12 patients expired at different times. Conclusions: Long-term regular follow-up is necessary after radioiodine ablation to become free of disease.
The influence of physical characteristics on ablation effects in UV laser assisted micro-engineering
NASA Astrophysics Data System (ADS)
Ostendorf, Andreas; Kulik, Christian J.; Temme, Thorsten; Otte, Frank; Samm, Katja
2004-10-01
The development of the recent years led to an increased importance of frequency-converted diode-pumped solid-state lasers (DPSSL) for industrial drilling, cutting and structuring applications. The UV laser systems show favorable beam absorption in a broad range of MEMS and MOEMS relevant materials like ceramics, metals and polymers. Their short pulses in the range of tH = 20 nanoseconds and the excellent beam quality offer the possibility of manufacturing with a minimum heat affected zone (HAZ) in the surrounding material and thereby a decreasing of initial fusing and debris. To obtain the reachable ablation quality, especially on metals, in this paper copper, tungsten, tantalum, molybdenum, nickel, iron, aluminum and titanium were machined under identical conditions. Material properties like heat conductivity, optical and thermal penetration depth, are decisive for the magnitude of the mentioned side-effects. The correlation of these physical values of different metals to those effects is the subject of this paper. Results of systematically accomplished experiences using a frequency tripled DPSSL with a wavelength of λ = 355 nm in order to investigate this correlation are presented. Due to thermal effects, the ablation quality of metals differ from each other extremely. These information enable a prediction of the reachable quality of the desired structure.
Defense Small Business Innovation Research Program (SBIR). Program Solicitation Number 89.1. FY-1989
1989-01-06
scale testing, such as plasma-arc and oxyacetylene torch test are performed. However, correlations to relate ablation rate from these test data to...helicopter rotor. In phase II, the contractor should construct and demonstrate a working model. 36 A89-010 TITLE: Smooth, Erosion Resistant Coatings ...for Organic Matrix Composites OBJECTIVE: Erosion Resistant Coatings for Organic Matrix Composites for use in Compressor Section of Future Gas Turbine
Román, Jessica K; Walsh, Callee M; Oh, Junho; Dana, Catherine E; Hong, Sungmin; Jo, Kyoo D; Alleyne, Marianne; Miljkovic, Nenad; Cropek, Donald M
2018-03-01
Laser-ablation electrospray ionization (LAESI) imaging mass spectrometry (IMS) is an emerging bioanalytical tool for direct imaging and analysis of biological tissues. Performing ionization in an ambient environment, this technique requires little sample preparation and no additional matrix, and can be performed on natural, uneven surfaces. When combined with optical microscopy, the investigation of biological samples by LAESI allows for spatially resolved compositional analysis. We demonstrate here the applicability of LAESI-IMS for the chemical analysis of thin, desiccated biological samples, specifically Neotibicen pruinosus cicada wings. Positive-ion LAESI-IMS accurate ion-map data was acquired from several wing cells and superimposed onto optical images allowing for compositional comparisons across areas of the wing. Various putative chemical identifications were made indicating the presence of hydrocarbons, lipids/esters, amines/amides, and sulfonated/phosphorylated compounds. With the spatial resolution capability, surprising chemical distribution patterns were observed across the cicada wing, which may assist in correlating trends in surface properties with chemical distribution. Observed ions were either (1) equally dispersed across the wing, (2) more concentrated closer to the body of the insect (proximal end), or (3) more concentrated toward the tip of the wing (distal end). These findings demonstrate LAESI-IMS as a tool for the acquisition of spatially resolved chemical information from fragile, dried insect wings. This LAESI-IMS technique has important implications for the study of functional biomaterials, where understanding the correlation between chemical composition, physical structure, and biological function is critical. Graphical abstract Positive-ion laser-ablation electrospray ionization mass spectrometry coupled with optical imaging provides a powerful tool for the spatially resolved chemical analysis of cicada wings.
NASA Astrophysics Data System (ADS)
Fisher, Christopher M.; Paton, Chad; Pearson, D. Graham; Sarkar, Chiranjeeb; Luo, Yan; Tersmette, Daniel B.; Chacko, Thomas
2017-12-01
A robust platform to view and integrate multiple data sets collected simultaneously is required to realize the utility and potential of the Laser Ablation Split-Stream (LASS) method. This capability, until now, has been unavailable and practitioners have had to laboriously process each data set separately, making it challenging to take full advantage of the benefits of LASS. We describe a new program for handling multiple mass spectrometric data sets collected simultaneously, designed specifically for the LASS technique, by which a laser aerosol is been split into two or more separate "streams" to be measured on separate mass spectrometers. New features within Iolite (https://iolite-software.com) enable the capability of loading, synchronizing, viewing, and reducing two or more data sets acquired simultaneously, as multiple DRSs (data reduction schemes) can be run concurrently. While this version of Iolite accommodates any combination of simultaneously collected mass spectrometer data, we demonstrate the utility using case studies where U-Pb and Lu-Hf isotope composition of zircon, and U-Pb and Sm-Nd isotope composition of monazite were analyzed simultaneously, in crystals showing complex isotopic zonation. These studies demonstrate the importance of being able to view and integrate simultaneously acquired data sets, especially for samples with complicated zoning and decoupled isotope systematics, in order to extract accurate and geologically meaningful isotopic and compositional data. This contribution provides instructions and examples for handling simultaneously collected laser ablation data. An instructional video is also provided. The updated Iolite software will help to fully develop the applications of both LASS and multi-instrument mass spectrometric measurement capabilities.
NASA Astrophysics Data System (ADS)
Vila Verde, A.; Ramos, M. M. D.; Stoneham, A. M.
2007-05-01
Human dental enamel has a porous mesostructure at the nanometre to micrometre scales that affects its thermal and mechanical properties relevant to laser treatment. We exploit finite-element models to investigate the response of this mesostructured enamel to mid-infrared lasers (CO2 at 10.6 µm and Er:YAG at 2.94 µm). Our models might easily be adapted to investigate ablation of other brittle composite materials. The studies clarify the role of pore water in ablation, and lead to an understanding of the different responses of enamel to CO2 and Er:YAG lasers, even though enamel has very similar average properties at the two wavelengths. We are able to suggest effective operating parameters for dental laser ablation, which should aid the introduction of minimally-invasive laser dentistry. In particular, our results indicate that, if pulses of ap10 µs are used, the CO2 laser can ablate dental enamel without melting, and with minimal damage to the pulp of the tooth. Our results also suggest that pulses with 0.1-1 µs duration can induce high stress transients which may cause unwanted cracking.
Studies of LA-ICP-MS on quartz glasses at different wavelengths of a Nd:YAG laser.
Becker, J S; Tenzler, D
2001-07-01
The capability of LA-ICP-MS for determination of trace impurities in transparent quartz glasses was investigated. Due to low or completely lacking absorption of laser radiation, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) proves difficult on transparent solids, and in particular the quantification of measurement results is problematic in these circumstances. Quartz glass reference materials of various compositions were studied by using a Nd:YAG laser system with focused laser radiation of wavelengths of 1064 nm, 532 nm and 266 nm, and an ICP-QMS (Elan 6000, Perkin Elmer). The influence of ICP and laser ablation conditions in the analysis of quartz glasses of different compositions was investigated, with the laser power density in the region of interaction between laser radiation and solid surface determining the ablation process. The trace element concentration was determined via calibration curves recorded with the aid of quartz glass reference materials. Under optimized measuring conditions the correlation coefficients of the calibration curves are in the range of 0.9-1. The relative sensitivity factors of the trace elements determined in the quartz glass matrix are 0.1-10 for most of the trace elements studied by LA-ICP-MS. The detection limits of the trace elements in quartz glass are in the low ng/g to pg/g range.
Zhu, Guo-Feng; Pu, Tao; He, Yuan-Qing; Wang, Pei-Zhen; Kong, Jian-Long; Zhang, Ning-Ning; Xin, Hui-Juan
2012-12-01
Melt water samples collected continuously from 29 August to 3 September 2009 in the Baishui Glacier No. 1 at elevation of 4750 m were analyzed for pH, conductivity, delta18O and inorganic ions. The results showed that the pH had obvious diurnal variations and was increased slightly by the influence of precipitation. The dissolution of alkaline soluble salts in the dust was the main reason for the increase of melt water conductivity; the value of delta18O was relatively low in strong ablation period and high in slight ablation period. Different from other research areas, the concentrations of Na+, K+, which were influenced by lithological and marine water vapor, were higher than that of Mg2+ in the study area; HCO3- and Ca2+ accounted for more than 80% of total ions in snow and ice melt water, indicating that the ions mainly came from limestone and the melt water was a typical carbonate solution; The content of melt water had an obvious daily change with temperature change, but the response amplitudes were different; Monsoon transport, local rock lithology, human industrial and agricultural activities were the main sources of inorganic ions and the deciding factors of the ion composition in the Baishui Glacier No. 1.
Excellence in the Knowledge-Based Economy: From Scientific to Research Excellence
ERIC Educational Resources Information Center
Sørensen, Mads P.; Bloch, Carter; Young, Mitchell
2016-01-01
In 2013, the European Union (EU) unveiled its new "Composite Indicator for Scientific and Technological Research Excellence." This is not an isolated occurrence; policy-based interest in excellence is growing all over the world. The heightened focus on excellence and, in particular, attempts to define it through quantitative indicators…
Probing the Allende meteorite with a miniature laser-ablation mass analyser for space application
NASA Astrophysics Data System (ADS)
Neuland, M. B.; Meyer, S.; Mezger, K.; Riedo, A.; Tulej, M.; Wurz, P.
2014-10-01
We measured the elemental composition on a sample of Allende meteorite with a miniature laser ablation mass spectrometer. This laser mass spectrometer (LMS) has been designed and built at the University of Bern in the Department of Space Research and Planetary Sciences with the objective of using such an instrument on a space mission. Utilising the meteorite Allende as the test sample in this study, it is demonstrated that the instrument allows the in situ determination of the elemental composition and thus mineralogy and petrology of untreated rocky samples, particularly on planetary surfaces. In total, 138 measurements of elemental compositions have been carried out on an Allende sample. The mass spectrometric data are evaluated and correlated with an optical image. It is demonstrated that by illustrating the measured elements in the form of mineralogical maps, LMS can serve as an element imaging instrument with a very high spatial resolution of μm scale. The detailed analysis also includes a mineralogical evaluation and an investigation of the volatile element content of Allende. All findings are in good agreement with published data and underline the high sensitivity, accuracy and capability of LMS as a mass analyser for space exploration.
NASA Astrophysics Data System (ADS)
Long, Yuting; Xie, Junliang; Li, Hong; Liu, Zirui; Xie, Yahong
2017-12-01
Jellylike cylinder graphene-Mn3O4 composite with highly coupled effect was successfully synthesized by a simple solvothermal process. Without using toxic reducing agent and expensive equipment, this method is environmental compatible and suitable for low cost mass production. High capacitance Mn3O4 nanoparticles are homogeneously anchored on excellent conductivity graphene framework and a growth mechanism is hypothesized. Excellent electron conductivity and unique structure of Mn3O4-graphene composite give rise to various applications such as microwave absorber and electrode material. As a microwave absorber, the composite exhibits lowest reflection loss of -14.2 dB in the frequency range of 2-18 GHz. Good microwave absorption performance is due to the structure of the composite where conductive channels form between nano sized Mn3O4 and high conductivity graphene with defects and dangling bonds. As for electrochemical property, Mn3O4-graphene composite with coupled effect shows excellent performance with highest specific capacitance of 246.7 F g-1 in saturated K2SO4 at a scan rate of 5 mV s-1. Good electrochemical property is also attributed to the structure with high utilization of Mn3O4, fast charge carrier transmission, and excellent electronic conductivity. This composite shows a promising application in absorbing materials and electrodes.
Perito, Brunella; Giorgetti, Emilia; Marsili, Paolo; Muniz-Miranda, Maurizio
2016-01-01
Silver nanoparticles (AgNPs) have increasingly gained importance as antibacterial agents with applications in several fields due to their strong, broad-range antimicrobial properties. AgNP synthesis by pulsed laser ablation in liquid (PLAL) permits the preparation of stable Ag colloids in pure solvents without capping or stabilizing agents, producing AgNPs more suitable for biomedical applications than those prepared with common, wet chemical preparation techniques. To date, only a few investigations into the antimicrobial effect of AgNPs produced by PLAL have been performed. These have mainly been performed by ablation in water with nanosecond pulse widths. We previously observed a strong surface-enhanced Raman scattering (SERS) signal from such AgNPs by "activating" the NP surface by the addition of a small quantity of LiCl to the colloid. Such surface effects could also influence the antimicrobial activity of the NPs. Their activity, on the other hand, could also be affected by other parameters linked to the ablation conditions, such as the pulse width. The antibacterial activity of AgNPs was evaluated for NPs obtained either by nanosecond (ns) or picosecond (ps) PLAL using a 1064 nm ablation wavelength, in pure water or in LiCl aqueous solution, with Escherichia coli and Bacillus subtilis as references for Gram-negative and Gram-positive bacteria, respectively. In all cases, AgNPs with an average diameter less than 10 nm were obtained, which has been shown in previous works to be the most effective size for bactericidal activity. The measured zeta-potential values were very negative, indicating excellent long-term colloidal stability. Antibacterial activity was observed against both microorganisms for the four AgNP formulations, but the ps-ablated nanoparticles were shown to more effectively inhibit the growth of both microorganisms. Moreover, LiCl modified AgNPs were the most effective, showing minimum inhibitory concentration (MIC) values in a restricted range of 1.0-3.7 µg/mL. An explanation is proposed for this result based on the increased surface reactivity of the metal surface due to the presence of positively charged active sites.
Abrego, Zuriñe; Grijalba, Nagore; Unceta, Nora; Maguregui, Maite; Sanchez, Alicia; Fernández-Isla, Alberto; Goicolea, M Aranzazu; Barrio, Ramón J
2014-12-07
A method based on scanning laser ablation and inductively coupled plasma-mass spectrometry (SLA-ICPMS) and Raman micro-spectroscopy for the detection and identification of compounds consistent with gunshot residue particles (GSR) has been developed. The method has been applied to the characterization of particles resulting from the discharge of firearms using lead-free ammunition. Modified tape lifts were used to collect the inorganic and organic residues from skin surfaces in a single sample. Using SLA-ICPMS, aggregates related to the composition of the ammunition, such as Cu-Zn-Sn, Zr-Sr, Cu-Zn, Al-Ti, or Al-Sr-Zr were detected, but this composition is only consistent with GSR from lead-free ammunitions. Additional evidence was provided by micro-Raman spectroscopy, which identified the characteristic organic groups of the particles as centralite, diphenylamine or their nitrated derivatives, which are indicative of GSR.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamad, Syed; Nageswara Rao, S. V. S.; Pathak, A. P.
2015-12-15
We report results from our studies on the fabrication and characterization of silicon (Si) nanoparticles (NPs) and nanostructures (NSs) achieved through the ablation of Si target in four different liquids using ∼2 picosecond (ps) pulses. The consequence of using different liquid media on the ablation of Si target was investigated by studying the surface morphology along with material composition of Si based NPs. The recorded mean sizes of these NPs were ∼9.5 nm, ∼37 nm, ∼45 nm and ∼42 nm obtained in acetone, water, dichloromethane (DCM) and chloroform, respectively. The generated NPs were characterized by selected area electron diffraction (SAED),more » high resolution transmission microscopy (HRTEM), Raman spectroscopic techniques and Photoluminescence (PL) studies. SAED, HRTEM and Raman spectroscopy data confirmed that the material composition was Si NPs in acetone, Si/SiO{sub 2} NPs in water, Si-C NPs in DCM and Si-C NPs in chloroform and all of them were confirmed to be polycrystalline in nature. Surface morphological information of the fabricated Si substrates was obtained using the field emission scanning electron microscopic (FESEM) technique. FESEM data revealed the formation of laser induced periodic surface structures (LIPSS) for the case of ablation in acetone and water while random NSs were observed for the case of ablation in DCM and chloroform. Femtosecond (fs) nonlinear optical properties and excited state dynamics of these colloidal Si NPs were investigated using the Z-scan and pump-probe techniques with ∼150 fs (100 MHz) and ∼70 fs (1 kHz) laser pulses, respectively. The fs pump-probe data obtained at 600 nm consisted of single and double exponential decays which were tentatively assigned to electron-electron collisional relaxation (<1 ps) and non-radiative transitions (>1 ps). Large third order optical nonlinearities (∼10{sup −14} e.s.u.) for these colloids have been estimated from Z-scan data at an excitation wavelength of 680 nm suggesting that the colloidal Si NPs find potential applications in photonic devices.« less
Wagner, Florian Mathias; Pecha, Simon; Conradi, Lenard; Reichenspurner, Hermann
2015-05-01
To analyze safety and efficacy of surgical totally endoscopic epimyocardial ablation in patients (pts) turned down for interventional catheter therapy due to long-standing persistent atrial fibrillation (pAF) combined with significant atrial dilatation (> 5 cm). Since December 2010, 15 pts were referred for surgical ablation due to persistent AF combined with biatrial dilatation (left atrium [LA] 5.0 ± 0.6 cm). Mean age was 52 ± 6 years, body mass index (BMI) 38 ± 6, duration of AF 2.8 ± 1.2 years, left ventricular end diastolic diameter (LVEDD) 5.8 cm ± 0.6 cm. Ablation was performed via a bilateral endoscopic approach using bipolar RF energy application. Monitoring was achieved by an event recorder (Reveal XT Medtronic, Inc., Minneapolis, MN, USA) or repeated 24-hours Holter electrocardiogram. All pts successfully received bilateral pulmonary vein isolation + box lesion + trigonal lesion + left atrial appendage resection. Mean duration of procedure was 235 ± 70 minutes. There was no intraoperative complication; however, one patient had persistent left phrenic nerve palsy. Mean hospital stay was 4 ± 2 days, mean follow-up time was 21 ± 11 months. Incidence of sinus rhythm (SR) was 67, 73, and 80% at discharge, three months, and 12 months follow-up. Mean LA diameter was reduced from 58.1 mm ± 6.0 mm preoperative to 49.7 mm ± 5.4 mm (p = 0.004) at 12 months follow-up. Incidence of SR was 86% at latest follow-up (mean time 21 months). All pts currently in SR (13/15 = 86%) are of class I or III antiarrhythmic drugs. Totally endoscopic left atrial ablation including left atrial resection can safely be performed. It achieved excellent rates of SR restoration in patients with long-standing persistent AF combined with significant atrial dilatation. © 2015 Wiley Periodicals, Inc.
Meng, Yuena; Wang, Kai; Zhang, Yajie; Wei, Zhixiang
2013-12-23
A highly flexible graphene free-standing film with hierarchical structure is prepared by a facile template method. With a porous structure, the film can be easily bent and cut, and forms a composite with another material as a scaffold. The 3D graphene film exhibits excellent rate capability and its capacitance is further improved by forming a composite with polyaniline nanowire arrays. The flexible hierarchical composite proves to be an excellent electrode material for flexible supercapacitors. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Assessment of refractive outcome of femtosecond-assisted LASIK for hyperopia correction
El-Naggar, Mohamed Tarek; Hovaghimian, Dikran Gilbert
2017-01-01
Introduction Laser vision correction for hyperopia is challenging. The purpose of the study was to assess the refractive outcomes of femtosecond-assisted laser in situ keratomileusis (LASIK) for hyperopic correction using wavefront-optimized ablation profiles. Methods This retrospective case series study included 20 Egyptian patients (40 eyes) with hyperopia or hyperopic astigmatism with a mean manifest refraction spherical equivalent (MRSE) of +2.55D±1.17 (range from +1.00 to +6.00) who had uneventful femtosecond-a assisted LASIK with wavefront-optimized aspheric ablation profile using refractive surgery suite (WaveLight FS200 Femtosecond Laser and WaveLight EX500 Excimer Laser) performed in the Research Institute of Ophthalmology and International Eye Hospital, Giza, Egypt. Statistical analysis was done using Microsoft Excel (Microsoft Corporation, Seattle, WA, USA). Results The procedure significantly reduced the MRSE and cylinder post-operatively (95% were ± 0.50D and 100% ± 1.00 D), with stability of refraction and UDVA over the follow-up period (up to 12 months) after surgery. No eye lost any line of the CDVA, which reflects the excellent safety profile of the procedure; on the other hand, one eye (5%) gained one line and one eye (5%) even gained two lines. There were no significant complications during the procedure. Conclusions Femtosecond-assisted laser in situ keratomileusis for hyperopia showed predictable, effective, and safe refractive outcomes that were stable through 12 months. Longer follow-up period is required to detect any further regression PMID:28461870
Jing, Lijia; Liang, Xiaolong; Deng, Zijian; Feng, Shanshan; Li, Xiaoda; Huang, Maomao; Li, Changhui; Dai, Zhifei
2014-07-01
The combination of CT imaging and photoacoustic (PA) imaging represents not only high resolution and ease of forming 3D visual image for locating tissues of interest, but also good soft tissue contrast and excellent high sensitivity, which is very beneficial to the precise guidance for photothermal therapy (PTT). The near infrared (NIR) absorbing Au nanostructures take advantages to operate as a CT contrast agent due to high absorption coefficient of X-ray and outstanding biocompatibility, but show obvious deficiency for PA imaging and PTT because of low photostability. Attacking this problem head on, the Au nanoparticles (NPs) were coated with Prussian blue (PB) which is a typical FDA-approved drug in clinic for safe and effective treatment of radioactive exposure. The obtained core/shell NPs of Au@PB NPs of 17.8 ± 2.3 nm were found to be an excellent photoabsorbing agent for both PTT and PA imaging due to high photostability and high molar extinction coefficient in NIR region. Their gold core of 9.1 ± 0.64 nm ensured a remarkable contrast enhancement for CT imaging. Through a one-time treatment of NIR laser irradiation after intravenous injection of Au@PB NPs, 100 mm(3) sized tumors in nude mice could be completely ablated without recurrence. Such versatile nanoparticles integrating effective cancer diagnosis with noninvasive therapy might bring opportunities to future cancer therapy. Copyright © 2014 Elsevier Ltd. All rights reserved.
Interaction of gases with ablative composites. I - Ar, CO2, and N2
NASA Technical Reports Server (NTRS)
King, C. A.; Wightman, J. P.
1974-01-01
The sorption of argon, carbon dioxide, and nitrogen on two heat shield composites (SLA-561 and SLA-561V) and on the SLA components was measured over the pressure range of 0.001 to 760 torr and in the temperature range of 30 to 50 C. The sorption of the gases by both the composites and the components varied directly with pressure. The sorption of CO2 by the phenolic spheres and the silicone elastomer and of Ar by the silicone elastomer varied inversely with temperature. The mechanism involved in the gas sorption was primarily absorption.
Generation of low work function, stable compound thin films by laser ablation
Dinh, Long N.; McLean, II, William; Balooch, Mehdi; Fehring, Jr., Edward J.; Schildbach, Marcus A.
2001-01-01
Generation of low work function, stable compound thin films by laser ablation. Compound thin films with low work function can be synthesized by simultaneously laser ablating silicon, for example, and thermal evaporating an alkali metal into an oxygen environment. For example, the compound thin film may be composed of Si/Cs/O. The work functions of the thin films can be varied by changing the silicon/alkali metal/oxygen ratio. Low work functions of the compound thin films deposited on silicon substrates were confirmed by ultraviolet photoelectron spectroscopy (UPS). The compound thin films are stable up to 500.degree. C. as measured by x-ray photoelectron spectroscopy (XPS). Tests have established that for certain chemical compositions and annealing temperatures of the compound thin films, negative electron affinity (NEA) was detected. The low work function, stable compound thin films can be utilized in solar cells, field emission flat panel displays, electron guns, and cold cathode electron guns.
Er:YAG laser for dentistry: basics, actual questions, and perspectives
NASA Astrophysics Data System (ADS)
Hibst, Raimund; Keller, Ulrich
1994-12-01
In recent years the dental use of the Er:YAG has found increasing interest. Most of the papers published so far concentrate on in vitro studies on cavity preparation, including the determination of ablation rates, measurements of temperature increase, microscopical analysis, and studies on the effect of water spray. The results are qualitatively in agreement and reveal a combination of high ablation efficiency and small side effects superior to other laser systems. Quantitative results, however, e.g., on ablation threshold or crater depths, sometimes differ. Some of these differences now can be explained and related to laser parameters or experimental conditions. Besides increasing the understanding on laser tissue interaction, the actual research enlarges the potential applications of the Er:YAG laser, such as for condition of enamel or dentin surfaces to enhance the bonding of composites. With the use of fibers, additional perspectives are given in periodontics and endodontics, e.g., for concrement removal or root canal preparation or sterilization.
NASA Astrophysics Data System (ADS)
Ishii, Katsunori; Kita, Tetsuya; Yoshikawa, Kazushi; Yasuo, Kenzo; Yamamoto, Kazuyo; Awazu, Kunio
2015-05-01
Less invasive methods for treating dental caries are strongly desired. However, conventional dental lasers do not always selectively remove caries or ensure good bonding to the composite resin. According to our previous study, demineralized dentin might be removed by a nanosecond pulsed laser operating at wavelengths of around 5.8 μm. The present study investigated the irradiation effect of the light on carious human dentin classified into "remove," "not remove," and "unclear" categories. Under 5.85-μm laser pulses, at average power densities of 30 W/cm2 and irradiation time of 2 s, the ablation depth of "remove" and "not remove," and also the ablation depth of "unclear" and "not remove," were significantly different (p<0.01). The ablation depth was correlated with both Vickers hardness and Ca content. Thus, a nanosecond pulsed laser operating at 5.85 μm proved an effective less-invasive caries treatment.
SnO2/Pt Thin Film Laser Ablated Gas Sensor Array
Shahrokh Abadi, Mohammad Hadi; Hamidon, Mohd Nizar; Shaari, Abdul Halim; Abdullah, Norhafizah; Wagiran, Rahman
2011-01-01
A gas sensor array was developed in a 10 × 10 mm2 space using Screen Printing and Pulse Laser Ablation Deposition (PLAD) techniques. Heater, electrode, and an insulator interlayer were printed using the screen printing method on an alumina substrate, while tin oxide and platinum films, as sensing and catalyst layers, were deposited on the electrode at room temperature using the PLAD method, respectively. To ablate SnO2 and Pt targets, depositions were achieved by using a 1,064 nm Nd-YAG laser, with a power of 0.7 J/s, at different deposition times of 2, 5 and 10 min, in an atmosphere containing 0.04 mbar (4 kPa) of O2. A range of spectroscopic diffraction and real space imaging techniques, SEM, EDX, XRD, and AFM were used in order to characterize the surface morphology, structure, and composition of the films. Measurement on the array shows sensitivity to some solvent and wood smoke can be achieved with short response and recovery times. PMID:22164041
An analysis of a charring ablator with thermal nonequilibrium, chemical kinetics, and mass transfer
NASA Technical Reports Server (NTRS)
Clark, R. K.
1973-01-01
The differential equations governing the transient response of a one-dimensional ablative thermal protection system are presented for thermal nonequilibrium between the pyrolysis gases and the char layer and with finite rate chemical reactions occurring. The system consists of three layers (the char layer, the uncharred layer, and an optical insulation layer) with concentrated heat sinks at the back surface and between the second and third layers. The equations are solved numerically by using a modified implicit finite difference scheme to obtain solutions for the thickness of the charred and uncharred layers, surface recession and pyrolysis rates, solid temperatures, porosity profiles, and profiles of pyrolysis-gas temperature, pressure, composition, and flow rate. Good agreement is obtained between numerical results and exact solutions for a number of simplified cases. The complete numerical analysis is used to obtain solutions for an ablative system subjected to a constant heating environment. Effects of thermal, chemical, and mass transfer processes are shown.
Thermal protection materials: Thermophysical property data
NASA Technical Reports Server (NTRS)
Williams, S. D.; Curry, Donald M.
1992-01-01
This publication presents a thermophysical property survey on materials that could potentially be used for future spacecraft thermal protection systems (TPS). This includes data that was reported in the 1960's as well as more current information reported through the 1980's. An attempt was made to cite the manufacturers as well as the data source in the bibliography. This volume represents an attempt to provide in a single source a complete set of thermophysical data on a large variety of materials used in spacecraft TPS analysis. The property data is divided into two categories: ablative and reusable. The ablative materials have been compiled into twelve categories that are descriptive of the material composition. An attempt was made to define the Arrhenius equation for each material although this data may not be available for some materials. In a similar manner, char data may not be available for some of the ablative materials. The reusable materials have been divided into three basic categories: thermal protection materials (such as insulators), adhesives, and structural materials.
Novel Hybrid Ablative/Ceramic Heatshield for Earth Atmospheric Re-Entry
NASA Astrophysics Data System (ADS)
Barcena, J.; Florez, S.; Perez, B.; Pinaud, G.; Bouilly, J.-M.; Fischer, W. P. P.; de Montburn, A.; Descomps, M.; Zuber, C.; Rotaermel, W.; Hald, H.; Pereira, C.; Mergia, K.; Triantou, K.; Marinou, A.; Vekinis, G.; Ionescu, G.; Ban, C.; Stefan, A.; Leroy, V.; Bernard, D.; Massuti, B.; Herdrich, G.
2014-06-01
Original approaches based on ablative materials and novel TPS solutions are required for space applications, where resistance to extreme oxidative environments and high temperatures are required. For future space exploration the demands for the thermal shield go beyond the current state-of-the-art. Therefore, the development of new thermal protection materials and systems at a reasonable mass budget is absolutely essential to ensure European non-dependence on corresponding restricted technologies. The three year long FP7 project HYDRA aims at the development of a novel thermal protection system through the integration of a low density ablative outer-shield on top of an advanced thermo-structural ceramic composite layer and will provide an innovative technology solution consistent with the capabilities of European technologies and material providers. This paper summarizes the current status of the scientific activities carried out after two years of progress in terms of design, integration and verification of a robust and lightweight thermal shield solution for atmospheric earth re-entry.
NASA Technical Reports Server (NTRS)
Kumar, A.; Graeves, R. A.
1980-01-01
A user's guide for a computer code 'COLTS' (Coupled Laminar and Turbulent Solutions) is provided which calculates the laminar and turbulent hypersonic flows with radiation and coupled ablation injection past a Jovian entry probe. Time-dependent viscous-shock-layer equations are used to describe the flow field. These equations are solved by an explicit, two-step, time-asymptotic finite-difference method. Eddy viscosity in the turbulent flow is approximated by a two-layer model. In all, 19 chemical species are used to describe the injection of carbon-phenolic ablator in the hydrogen-helium gas mixture. The equilibrium composition of the mixture is determined by a free-energy minimization technique. A detailed frequency dependence of the absorption coefficient for various species is considered to obtain the radiative flux. The code is written for a CDC-CYBER-203 computer and is capable of providing solutions for ablated probe shapes also.
Jin, Cheng S.; Lovell, Jonathan F.; Zheng, Gang
2013-01-01
We recently developed porphysomes as intrinsically multifunctional nanovesicles. A photosensitizer, pyropheophorbide α, was conjugated to a phospholipid and then self-assembled to liposome-like spherical vesicles. Due to the extremely high density of porphyrin in the porphyrin-lipid bilayer, porphysomes generated large extinction coefficients, structure-dependent fluorescence self-quenching, and excellent photothermal efficacy. In our formulation, porphysomes were synthesized using high pressure extrusion, and displayed a mean particle size around 120 nm. Twenty-four hr post-intravenous injection of porphysomes, the local temperature of the tumor increased from 30 °C to 62 °C rapidly upon one minute exposure of 750 mW (1.18 W/cm2), 671 nm laser irradiation. Following the complete thermal ablation of the tumor, eschars formed and healed within 2 weeks, while in the control groups the tumors continued to grow and all reached the defined end point within 3 weeks. These data show how porphysomes can be used as potent photothermal therapy (PTT) agents. PMID:24084712
Xiao, Qingfeng; Zheng, Xiangpeng; Bu, Wenbo; Ge, Weiqiang; Zhang, Shengjian; Chen, Feng; Xing, Huaiyong; Ren, Qingguo; Fan, Wenpei; Zhao, Kuaile; Hua, Yanqing; Shi, Jianlin
2013-09-04
To integrate photothermal ablation (PTA) with radiotherapy (RT) for improved cancer therapy, we constructed a novel multifunctional core/satellite nanotheranostic (CSNT) by decorating ultrasmall CuS nanoparticles onto the surface of a silica-coated rare earth upconversion nanoparticle. These CSNTs could not only convert near-infrared light into heat for effective thermal ablation but also induce a highly localized radiation dose boost to trigger substantially enhanced radiation damage both in vitro and in vivo. With the synergistic interaction between PTA and the enhanced RT, the tumor could be eradicated without visible recurrence in 120 days. Notably, hematological analysis and histological examination unambiguously revealed their negligible toxicity to the mice within a month. Moreover, the novel CSNTs facilitate excellent upconversion luminescence/magnetic resonance/computer tomography trimodal imagings. This multifunctional nanocomposite is believed to be capable of playing a vital role in future oncotherapy by the synergistic effects between enhanced RT and PTA under the potential trimodal imaging guidance.
NASA Astrophysics Data System (ADS)
Choi, Jihye; Park, Yeonji; Choi, Eun Bi; Kim, Hyun-Ouk; Kim, Dong Joo; Hong, Yoochan; Ryu, Sung-Ho; Lee, Jung Hwan; Suh, Jin-Suck; Yang, Jaemoon; Huh, Yong-Min; Haam, Seungjoo
2014-05-01
Biomarker-specific photothermal nanoparticles that can efficiently sense markers that are overexpressed in distinguished adenocarcinomas have attracted much interest in an aspect of efficacy increase of cancer treatment. We demonstrated a promising prospect of a smart photothermal therapy agent employing anti-epidermal growth factor receptor aptamer (AptEGFR)-conjugated polyethylene glycol (PEG) layted gold nanorods (AptEGFR-PGNRs). The cetyltrimethylammonium bromide bilayer on GNRs was replaced with heterobifunctional PEG (COOH-PEG-SH) not only to serve as a biocompatible stabilizer and but also to conjugate Apt. Subsequently, to direct photothermal therapy agent toward epithelial cancer cells, the carboxylated PEGylated GNRs (PGNRs) were further functionalized with Apt using carbodiimide chemistry. Then, to assess the potential as biomarker-specific photothermal therapy agent of synthesized Apt-PGNRs, the optical properties, biocompatibility, colloidal stability, binding affinity, and epicellial cancer cell killing efficacy in vitro/in vivo under near-infrared laser irradiation were investigated. As a result, Apt-PGNRs exhibit excellent tumor targeting ability and feasibility of effective photothermal ablation cancer therapy.
NASA Astrophysics Data System (ADS)
Barcena, Jorge; Garmendia, Iñaki; Triantou, Kostoula; Mergia, Konstatina; Perez, Beatriz; Florez, Sonia; Pinaud, Gregory; Bouilly, Jean-Marc; Fischer, Wolfgang P. P.
2017-05-01
A new thermal protection system for atmospheric earth re-entry is proposed. This concept combines the advantages of both reusable and ablative materials to establish a new hybrid concept with advanced capabilities. The solution consists of the design and the integration of a dual shield resulting on the overlapping of an external thin ablative layer with a Ceramic Matrix Composite (CMC) thermo-structural core. This low density ablative material covers the relatively small heat peak encountered during re-entry the CMC is not able to bear. On the other hand the big advantage of the CMC based TPS is of great benefit which can deal with the high integral heat for the bigger time period of the re-entry. To verify the solution a whole testing plan is envisaged, which as part of it includes thermal shock test by infra-red heating (heating flux up to 1 MW/m2) and vibration test under launcher conditions (Volna and Ariane 5). Sub-scale tile samples (100×100 mm2) representative of the whole system (dual ablator/ceramic layers, insulation, stand-offs) are specifically designed, assembled and tested (including the integration of thermocouples). Both the thermal and the vibration test are analysed numerically by simulation tools using Finite Element Models. The experimental results are in good agreement with the expected calculated parameters and moreover the solution is qualified according to the specified requirements.
Parameters optimization for synthesis of Al-doped ZnO nanoparticles by laser ablation in water
NASA Astrophysics Data System (ADS)
Krstulović, Nikša; Salamon, Krešimir; Budimlija, Ognjen; Kovač, Janez; Dasović, Jasna; Umek, Polona; Capan, Ivana
2018-05-01
Al-doped ZnO crystalline colloidal nanoparticles were synthesized by a laser ablation of ZnO:Al2O3 in MilliQ water. Experiments were performed systematically by changing the number of applied laser pulses and laser output energy with the aim to affect the nanoparticle size, composition (Al/Zn ratio) and characteristics (band-gap, crystallinity). Distinctly, set of nanoparticle syntheses was performed in deionized water for comparison. SEM investigation of colloidal nanoparticles revealed that the formed nanoparticles are 30 nm thick discs with average diameters ranging from 450 to 510 nm. It was found that craters in the target formed during the laser ablation influence the size of synthesized colloidal nanoparticles. This is explained by efficient nanoparticle growth through diffusion process which take place in spatially restricted volume of the target crater. When laser ablation takes place in deionized water the synthesized nanoparticles have a mesh-like structure with sparse concentration of disc-like nanoparticles. Al/Zn ratio and band-gap energy of nanoparticles are highly influenced by the number and output energy of applied laser pulses. In addition, the procedure how to calculate the concentration of colloidal nanoparticles synthesized by laser ablation in liquids is proposed. The Al-doped ZnO colloidal nanoparticles properties were obtained using different techniques like scanning electron microscopy, optical microscopy, energy-dispersive X-ray spectroscopy, grazing-incidence X-ray diffraction, photoabsorption, photoluminescence and X-ray photoelectron spectroscopy.
NASA Astrophysics Data System (ADS)
Wang, Haiyan; Wang, Weizong; Yan, Joseph D.; Qi, Haiyang; Geng, Jinyue; Wu, Yaowu
2017-10-01
Ablation-controlled plasmas have been used in a range of technical applications where local thermodynamic equilibrium (LTE) is often violated near the wall due to the strong cooling effect caused by the ablation of wall materials. The thermodynamic and transport properties of ablated polytetrafluoroethylene (PTFE) vapor, which determine the flowing plasma behavior in such applications, are calculated based on a two-temperature model at atmospheric pressure. To our knowledge, no data for PTFE have been reported in the literature. The species composition and thermodynamic properties are numerically determined using the two-temperature Saha equation and the Guldberg-Waage equation according to van de Sanden et al’s derivation. The transport coefficients, including viscosity, thermal conductivity and electrical conductivity, are calculated with the most recent collision interaction potentials using Devoto’s electron and heavy-particle decoupling approach but expanded to the third-order approximation (second-order for viscosity) in the frame of the Chapman-Enskog method. Results are computed for different degrees of thermal non-equilibrium, i.e. the ratio of electron to heavy-particle temperatures, from 1 to 10, with electron temperature ranging from 300 to 40 000 K. Plasma transport properties in the LTE state obtained from the present work are compared with existing published results and the causes for the discrepancy analyzed. The two-temperature plasma properties calculated in the present work enable the modeling of wall ablation-controlled plasma processes.
NASA Astrophysics Data System (ADS)
Warner, J. D.; Meola, J. E.; Jenkins, K. A.; Bhasin, K. B.
1990-04-01
The development of high temperature superconducting YBa2Cu3O(7-x) thin films on substrates suitable for microwave applications is of great interest for evaluating their applications for space radar, communication, and sensor systems. Thin films of YBa2Cu3O(7-x) were formed on SrTiO3, ZrO2, MgO, and LaAlO3 substrates by laser ablation. The wavelength used was 248 nm from a KrF excimer laser. During deposition the films were heated to 600 C in a flowing oxygen environment, and required no post annealing. The low substrate temperature during deposition with no post annealing gave films which were smooth, which had their c-axis aligned to the substrates, and which had grains ranging from 0.2 to 0.5 microns in size. The films being c-axis aligned gave excellent surface resistance at 35 GHz which was lower than that of copper at 77 K. At present, LaAlO3 substrates with a dielectric constant of 22, appears suitable as a substrate for microwave and electronic applications. The films were characterized by resistance-temperature measurements, scanning electron microscopy, and x ray diffraction. The highest critical transition temperatures (T sub c) are above 89 K for films on SrTiO3 and LaAlO3, above 88 K for ZrO2, and above 86 K for MgO. The critical current density (J sub c) of the films on SrTiO3 is above 2 x 10(exp 6) amperes/sq cm at 77 K. The T(sub c) and J(sub c) are reported as a function of laser power, composition of the substrate, and temperature of the substrate during deposition.
V-378A: A modified bismaleimide for advanced composites
NASA Technical Reports Server (NTRS)
Street, S. W.
1985-01-01
Addition polyimides cure with no evolution of gaseous by-products at relatively low temperatures and may be cured at low pressures to yield composites with excellent hot-wet strength retention. These properaties have made them excellent candidates as matrix resins for advanced composites. However, commercially available bismaleimides are solids and difficult to handle in preimpregnated form. V-378A is an addition polyimide composed of a mixture of bismaleimides and other reactive ingredients formulated to provide good prepreg properties and handling, facile cure and excellent composite mechanical properties. Several curing mechanisms are utilized to provide the characteristics exhibited by V-378A. Part of the mechanism is free radial and takes place at ambient temperature and above. Other mechanisms are principally Diels-Alder in nature. V-378A prepregs are tacky at ambient temperature, but do not have long tacky outlife similar to some epoxies. V-378A yields composites which exhibit hot-wet strength retention which is superior to that provided by epoxy resin systems.
Radio-physical properties of radiotransparent thermal protection materials in ablation mode
NASA Astrophysics Data System (ADS)
Petrovskiy, V. P.; Pakhomov, E. P.; Politiko, A. A.; Semenenko, V. N.; Chistyaev, V. A.; Balakirev, B. A.; Pervov, A. Yu; Kamalov, A. D.; Sotskova, L. P.
2018-01-01
Experimental method for assessing the impact of the effects of high-temperature ablation processes on the radio physical characteristics of radiotransparent thermal protection materials (RTPM) is developed. Researches for the following RTPM with various structures of glass fillers are completed: press material (radiotransparent thermal protection press material or RTP-200); glass-fiber laminate (glass-fiber radiotransparent organic ceramic matrix or GFR-CM); reinforced composite material of class SiO2-SiO2 (high-temperature radiotransparent ceramic organic matrix or HTRC-OM). The influence of physicochemical transformations in the surface layer of RTPM on transmission and reflection coefficients of electromagnetic waves of RTPM samples and on the value of their complex permittivity is determined.
Nur-E-Alam, M; Islam, M Monirul; Islam, M Nazrul; Rima, Farhana Rahman; Islam, M Nurul
2016-03-01
The cleansing efficiencies of laundry detergents depend on composition and variation of ingredients such as surfactants, phosphate, and co-builders. Among these ingredients, surfactants and phosphate are considered as hazardous materials. Knowledge on compositions and micellar behavior is very useful for understanding their cleansing efficiencies and environmental impact. With this view, composition, critical micelle concentration, and dissolved oxygen level in aqueous solution of some laundry detergents available in Bangladesh such as keya, Wheel Power White, Tibet, Surf Excel, and Chaka were determined. Surfactant and phosphate were found to be maximum in Surf Excel and Wheel Power White, respectively, while both of the ingredients were found to be minimum in Tibet. The critical micelle concentration decreased with increasing surfactant content. The amount of laundry detergents required for efficient cleansing was found to be minimum for Surf Excel and maximum for Chaka; however, cleansing cost was the highest for Surf Excel and the lowest for Tibet. The maximum amount of surfactants and phosphate was discharged by Surf Excel and Wheel Power White, respectively, while discharges of both of the ingredients were minimum for Tibet. The maximum decrease of dissolved oxygen level was caused by Surf Excel and the minimum by Tibet. Therefore, it can be concluded that Tibet is cost-effective and environment friendly, whereas Surf Excel and Wheel Power White are expensive and pose a threat to water environment.
Nano-fibrillated cellulose-hydroxyapatite based composite foams with excellent fire resistance.
Guo, Wenwen; Wang, Xin; Zhang, Ping; Liu, Jiajia; Song, Lei; Hu, Yuan
2018-09-01
Thermally insulating materials made from renewable resources are desirable for energy efficient buildings. Traditional petroleum-derived insulating materials such as rigid polyurethane foam and expanded polystyrene display poor flame retardancy and inorganic insulating materials such as silica aerogel are fragile. Herein, we reported a facile approach to prepare cellulose nanofiber (CNF)-hydroxyapatite (HAP) composite foam by a simple freeze-drying process. The resultant HAP-CNF composite foams showed a thermal conductivity in the range of 38.5-39.1 mW/(m K) and very low peak heat release rate (20.4 kW/m 2 ) and total heat release (1.21 MJ/m 2 ). Vertical burning tests also manifested excellent fire resistance and self-extinguishing behaviours. Considering the excellent fire resistance of this composite foam, it is of significance to fire safety solution for buildings insulating materials. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zeng, Yu; Chen, XiFang; Yi, Zao; Yi, Yougen; Xu, Xibin
2018-05-01
The pyramidal silicon substrate is formed by wet etching, then ZnO nanorods are grown on the surface of the pyramidal microstructure by a hydrothermal method to form a moth-eye composite heterostructure. The composite heterostructure of this material determines its excellent anti-reflection properties and ability to absorb light from all angles. In addition, due to the effective heterojunction binding area, the composite micro/nano structure has excellent photoelectric conversion performance. Its surface structure and the large specific surface area gives the material super hydrophilicity, excellent gas sensing characteristic, and photocatalytic properties. Based on the above characteristics, the micro/nano heterostructure can be used in solar cells, sensors, light-emitting devices, and photocatalytic fields.
Effect of composition and strain on the electrical properties of LaNiO3 thin films
NASA Astrophysics Data System (ADS)
Zhu, Mingwei; Komissinskiy, Philipp; Radetinac, Aldin; Vafaee, Mehran; Wang, Zhanjie; Alff, Lambert
2013-09-01
The Ni content of LaNi1-xO3 epitaxial thin films grown by pulsed laser deposition has been varied by ablation from targets with different composition. While tensile strain and Ni substoichiometry reduce the conductivity, nearly stoichiometric and unstrained films show reproducibly resistivities below 100 μΩ × cm. Since the thermodynamic instability of the Ni3+ state drives defect formation, Ni defect engineering is the key to obtain highly conducting LaNiO3 thin films.
Experimental investigation on IXV TPS interface effects in Plasmatron
NASA Astrophysics Data System (ADS)
Ceglia, Giuseppe; Trifoni, Eduardo; Gouriet, Jean-Baptiste; Chazot, Olivier; Mareschi, Vincenzo; Rufolo, Giuseppe; Tumino, Giorgio
2016-06-01
An experimental investigation related to the thermal protection system (TPS) interfaces of the intermediate experimental vehicle has been carried out in the Plasmatron facility at the von Karman Institute for fluid dynamics. The objective of this test campaign is to qualify the thermal behaviours of two different TPS interfaces under flight representative conditions in terms of heat flux and integral heat load ( 180 kW/m2 for 700 s). Three test samples are tested in off-stagnation configuration installed on an available flat plate holder under the same test conditions. The first junction is composed of an upstream ceramic matrix composite (CMC) plate and an ablative P50 cork composite block separated by a gap of 2 mm. The second one is made of an upstream P50 block and a downstream ablative SV2A silicon elastomer block with silicon-based filler in between. A sample composed of P50 material is tested in order to obtain reference results without TPS interface effect. The overheating at the CMC-P50 interface due to the jump of the catalytic properties of the materials, and the recession/swelling behaviour of the P50-SV2A interface are under investigation. All the test samples withstand relatively well the imposed heat flux for the test duration. As expected, both the ablative materials undergo a thermal degradation. The P50 exhibits the formation of a porous char layer and its recession; on the other hand, the SV2A swells and forms a fragile char layer.
Cold Atmospheric Plasma for Selectively Ablating Metastatic Breast Cancer Cells
Wang, Mian; Holmes, Benjamin; Cheng, Xiaoqian; Zhu, Wei; Keidar, Michael; Zhang, Lijie Grace
2013-01-01
Traditional breast cancer treatments such as surgery and radiotherapy contain many inherent limitations with regards to incomplete and nonselective tumor ablation. Cold atomospheric plasma (CAP) is an ionized gas where the ion temperature is close to room temperature. It contains electrons, charged particles, radicals, various excited molecules, UV photons and transient electric fields. These various compositional elements have the potential to either enhance and promote cellular activity, or disrupt and destroy them. In particular, based on this unique composition, CAP could offer a minimally-invasive surgical approach allowing for specific cancer cell or tumor tissue removal without influencing healthy cells. Thus, the objective of this research is to investigate a novel CAP-based therapy for selectively bone metastatic breast cancer treatment. For this purpose, human metastatic breast cancer (BrCa) cells and bone marrow derived human mesenchymal stem cells (MSCs) were separately treated with CAP, and behavioral changes were evaluated after 1, 3, and 5 days of culture. With different treatment times, different BrCa and MSC cell responses were observed. Our results showed that BrCa cells were more sensitive to these CAP treatments than MSCs under plasma dose conditions tested. It demonstrated that CAP can selectively ablate metastatic BrCa cells in vitro without damaging healthy MSCs at the metastatic bone site. In addition, our study showed that CAP treatment can significantly inhibit the migration and invasion of BrCa cells. The results suggest the great potential of CAP for breast cancer therapy. PMID:24040051
Influence of temperature on the CuIn1-xGaxSe2films deposited by picosecond laser ablation
NASA Astrophysics Data System (ADS)
Sima, Cornelia; Toma, Ovidiu
2017-12-01
The goal of this study is to investigate the influence of the deposition temperature on the CuIn1-xGaxSe2 (CIGS-copper indium gallium diselenide) film characteristics deposited by picosecond laser ablation method using a Nd:YVO4 laser (8 ps, 0.2 W, 50 kHz, 532 nm; 5.7 mJ/cm2; 36 × 107 pulses). The films were deposited starting from a CuIn0.7Ga0.3Se2 target, in vacuum at 3 × 10-5 Torr for 2 h, at room temperature (RT) and 100/200/300/400 °C substrate temperature; as substrate, optical glass was used. Structure, film morphology, composition and optical properties were investigated by X ray diffraction, scanning electron microscopy (energy dispersive X ray spectroscopy), spectroscopic ellipsometry and optical spectrophotometry. CIGS crystalline films have the dominant peak corresponding to (112) direction more pronounced starting with 200 °C deposition temperature. The thickness gradually decreased with temperature increasing, being 1.44 μm at RT and 0.72 μm at 400 °C; atomic composition in the case of In, Ga, Se increased after annealing, while in the case of Cu it decreased comparing with RT; refractive indices exhibited a short decreasing tendency by increasing the deposition temperature, while the optical band gap values for CuIn0.7Ga0.3Se2 laser ablated thin films increased.
Foraminiferal Stable Isotope Geochemistry At The Micrometer Scale: Is It A Dream Or Reality?
NASA Astrophysics Data System (ADS)
Misra, S.; Shuttleworth, S.; Lloyd, N. S.; Sadekov, A.; Elderfield, H.
2012-12-01
Over last few decades trace metals and stable isotope compositions of foraminiferal shells became one of the major tools to study past oceans and associated climate change. Empirical calibrations of δ11B, δ18O, Mg/Ca, Cd/Ca, Ba/Ca shells compositions have linked them to various environmental parameters such as seawater pH, temperature, salinity and productivity. Despite their common use as proxies, little is known about mechanisms of trace metals incorporation into foraminiferal calcite. Trace metals partition coefficients for foraminiferal calcite is significantly different from inorganic calcite precipitates underlining strong biological control on metal transport to the calcification sites and their incorporation into the calcite. Microscale distribution of light elements isotopes (e.g. Li, B, Mg) could potentially provide unique inside into these biomineralization processes improving our understanding of foraminiferal geochemistry. In this work we explore potentials of using recent advances in analytical geochemistry by employing laser ablation and multi-collector ICP-MS to study microscale distribution of Mg isotopes across individual foraminiferal shells and δ11B, and δ7Li analyses of individual shell chambers. The analytical setup includes an Analyte.G2 193nm excimer laser ablation system with two volume ablation cell connected to a Thermo Scientific NEPTUNE Plus MC-ICP-MS with Jet Interface option. We will discuss method limitations and advantages for foraminiferal geochemistry as well as our data on Mg isotopes distribution within shells of planktonic foraminifera.
NASA Astrophysics Data System (ADS)
Vašinová Galiová, Michaela; Čopjaková, Renata; Škoda, Radek; Štěpánková, Kateřina; Vaňková, Michaela; Kuta, Jan; Prokeš, Lubomír; Kynický, Jindřich; Kanický, Viktor
2014-10-01
A 213 nm Nd:YAG-based laser ablation (LA) system coupled to quadrupole-based inductively coupled plasma-mass spectrometer and an ArF* excimer-based LA-system coupled to a double-focusing sector field inductively coupled plasma-mass spectrometer were employed to study the spatial distribution of various elements in kidney stones (uroliths). Sections of the surfaces of uroliths were ablated according to line patterns to investigate the elemental profiles for the different urolith growth zones. This exploratory study was mainly focused on the distinguishing of the main constituents of urinary calculus fragments by means of LA-ICP-mass spectrometry. Changes in the ablation rate for oxalate and phosphate phases related to matrix density and hardness are discussed. Elemental association was investigated on the basis of 2D mapping. The possibility of using NIST SRM 1486 Bone Meal as an external standard for calibration was tested. It is shown that LA-ICP-MS is helpful for determination of the mineralogical composition and size of all phases within the analyzed surface area, for tracing down elemental associations and for documenting the elemental content of urinary stones. LA-ICP-MS results (elemental contents and maps) are compared to those obtained with electron microprobe analysis and solution analysis ICP-MS.
Urgast, Dagmar S; Ellingsen, Dag G; Berlinger, Balázs; Eilertsen, Einar; Friisk, Grete; Skaug, Vidar; Thomassen, Yngvar; Beattie, John H; Kwun, In-Sook; Feldmann, Jörg
2012-07-01
In recent years, bismuth has been promoted as a "green element" and is used as a substitute for the toxic lead in ammunition and other applications. However, the bioavailability and toxicity of bismuth is still not very well described. Following a hunting accident with bismuth-containing shots, a bioavailability study of bismuth from metal pellets inoculated into rat limb muscles was carried out. Bismuth could be found in urine and blood of the animals. Bio-imaging using laser ablation ICP-MS of thin sections of the tissue around the metal implant was carried out to find out more about the distribution of the metal diffusing into the tissue. Two laser ablation systems with different ablation cell designs were compared regarding their analytical performance. Low concentrations of bismuth showing a non-symmetrical pattern were detected in the tissue surrounding the metal implant. This was partly an artefact from cutting the thin sections but also bio-mobilisation of the metals of the implant could be seen. An accumulation of zinc around the implant was interpreted as a marker of inflammation. Challenges regarding sample preparation for laser ablation and bio-imaging of samples of diverse composition became apparent during the analysis.
Erel, Eric; Aubriet, Frédéric; Finqueneisel, Gisèle; Muller, Jean-François
2003-12-01
The potentialities of laser ablation coupled to ion cyclotron resonance Fourier transform mass spectrometry are evaluated to distinguish natural and artificial opals. The detection of specific species in both ion detection modes leads us to obtain relevant criteria of differentiation. In positive ions, species including hafnium and large amounts of zirconium atoms are found to be specific for artificial opal. In contrast, aluminum, titanium, iron, and rubidium are systematically detected in the study of natural opals. Moreover, some ions allow us to distinguish between natural opal from Australia and from Mexico. Australian gemstone includes specifically strontium, cesium, and barium. Moreover, it is also found that the yield of (H2O)0-1(SiO2)nX- (X- = O-, OH-, KO-, NaO-, SiO2-, AlO1-2-, FeO2-, ZrO2-, and ZrO3-) and (Al2O3)(SiO2)nAlO2- ions depends on the composition of the sample when opals are laser ablated. Ions, which include zirconium oxide species, are characteristics of artificial gem. In contrast, natural opals lead us, after laser ablation, to the production of ions including H2O, Al2O3 motifs and AlO-, KO-, NaO-, and FeO2- species.
Vangipuram, Ramya K; DeLozier, Whitney L; Geddes, Elizabeth; Friedman, Paul M
2016-03-01
Pigmentation secondary to minocycline ingestion is an uncommon adverse event affecting 3.7-14.8% of treated individuals for which few effective therapies are available. Three patterns of minocycline pigmentation have a characteristic clinical and histological appearance. The pigment composition in each variety is different and occurs at varying skin depths. Accordingly, a tailored approach according to the type of minocycline pigmentation is crucial for treatment success. The purpose of this intervention was to evaluate the efficacy of non-ablative fractional photothermolysis in combination with the Q-switched alexandrite laser for the treatment of type I minocycline pigmentation on the face. A patient with type I minocycline pigmentation was treated with non-ablative 1550-nm fractional photothermolysis followed immediately by 755-nm Q-switched alexandrite laser and then observed clinically to determine the outcome of this modality. The patient was seen in clinic 1 month later following her single treatment session and 100% clearance of all blue facial pigment was observed. Non-ablative fractional photothermolysis in combination with the 755-nm Q-switched alexandrite laser should be considered for treatment of type I minocycline pigmentation. © 2015 Wiley Periodicals, Inc.
Electronic-beam analysis of excimer lasers used for photorefractive keratotomy
NASA Astrophysics Data System (ADS)
Roundy, Carlos B.
1998-07-01
Excimer lasers are an excellent instrument for performing photorefractive keratotomy, PRK. The UV light from the laser causes an ablation of the cornea in proportion to the intensity of the light. The primary characteristic essential to successful PRK is the uniformity of the Top Hat, or working portion of the laser beam. In order for this intensity profile to be sufficiently uniform for PRK, it is essential to periodically measure the equality of the laser beam profile. This ensures that the laser continues to operate properly and provide the expected performance.
Ye, Yixing; Wang, Panpan; Dai, Enmei; Liu, Jun; Tian, Zhenfei; Liang, Changhao; Shao, Guosheng
2014-05-21
Quantum-sized SnO2 nanocrystals can be well dispersed on reduced graphene oxide (rGO) nanosheets through a convenient one-pot in situ reduction route without using any other chemical reagent or source. Highly reactive metastable tin oxide (SnO(x)) nanoparticles (NPs) were used as reducing agents and composite precursors derived by the laser ablation in liquid (LAL) technique. Moreover, the growth and phase transition of LAL-induced SnO(x) NPs and graphene oxide (GO) were examined by optical absorption, X-ray diffraction, X-ray photoelectron spectroscopy, Raman spectroscopy and high-resolution transmission electron microscopy. Highly dispersed SnO(x) NPs can also prevent rGO from being restacked into a multilayer structure during GO reduction. Given the good electron transfer ability and unsaturated dangling bonds of rGO, as well as the ample electrocatalytic active sites of quantum-sized SnO2 NPs on unfolded rGO sheets, the fabricated SnO2-rGO nanocomposite exhibited excellent performance in the non-enzymatic electrochemical detection of glucose molecules. The use of LAL-induced reactive NPs for in situ GO reduction is also expected to be a universal and environmentally friendly approach for the formation of various rGO-based nanocomposites.
Details on Silica-Rich Elk Target near Marias Pass
2015-12-17
This image from the Chemistry and Camera (ChemCam) instrument on NASA's Curiosity Mars rover shows detailed texture of a rock target called "Elk" on Mars' Mount Sharp, revealing laminations that are present in much of the Murray Formation geological unit of lower Mount Sharp. Researchers also used ChemCam's laser and spectrometers to assess Elk's composition and found it to be rich in silica. The image covers a patch of rock surface about 2.8 inches (7 centimeters) across. It was taken on May 22, 2015, during the mission's 992nd Martian day, or sol. ChemCam's Remote Micro-Imager camera, on top of Curiosity's mast, captured the image from a distance of about 9 feet (2.75 meters). Annotations in red identify five points on Elk that were hit with ChemCam's laser. Each of the highlighted points is a location where ChemCam fired its laser 30 times to ablate a tiny amount of target material. By analyzing the light emitted from this laser-ablation, researchers can deduce the composition of that point. For some purposes, composition is presented as a combination of the information from multiple points on the same rock. However, using the points individually can track fine-scale variations in targets. http://photojournal.jpl.nasa.gov/catalog/PIA20267
Chu, Edward P F; Elso, Colleen M; Pollock, Abigail H; Alsayb, May A; Mackin, Leanne; Thomas, Helen E; Kay, Thomas W H; Silveira, Pablo A; Mansell, Ashley S; Gaus, Katharina; Brodnicki, Thomas C
2017-02-01
During immune cell activation, serine-derived lipids such as phosphatidylserine and sphingolipids contribute to the formation of protein signaling complexes within the plasma membrane. Altering lipid composition in the cell membrane can subsequently affect immune cell function and the development of autoimmune disease. Serine incorporator 1 (SERINC1) is a putative carrier protein that facilitates synthesis of serine-derived lipids. To determine if SERINC1 has a role in immune cell function and the development of autoimmunity, we characterized a mouse strain in which a retroviral insertion abolishes expression of the Serinc1 transcript. Expression analyses indicated that the Serinc1 transcript is readily detectable and expressed at relatively high levels in wildtype macrophages and lymphocytes. The ablation of Serinc1 expression in these immune cells, however, did not significantly alter serine-derived lipid composition or affect macrophage function and lymphocyte proliferation. Analyses of Serinc1-deficient mice also indicated that systemic ablation of Serinc1 expression did not affect viability, fertility or autoimmune disease susceptibility. These results suggest that Serinc1 is dispensable for certain immune cell functions and does not contribute to previously reported links between lipid composition in immune cells and autoimmunity. Copyright © 2016 Elsevier Ltd. All rights reserved.
Frick, Daniel A; Schuessler, Jan A; von Blanckenburg, Friedhelm
2016-09-28
Stable metal (e.g. Li, Mg, Ca, Fe, Cu, Zn, and Mo) and metalloid (B, Si, Ge) isotope ratio systems have emerged as geochemical tracers to fingerprint distinct physicochemical reactions. These systems are relevant to many Earth Science questions. The benefit of in situ microscale analysis using laser ablation (LA) over bulk sample analysis is to use the spatial context of different phases in the solid sample to disclose the processes that govern their chemical and isotopic compositions. However, there is a lack of in situ analytical routines to obtain a samples' stable isotope ratio together with its chemical composition. Here, we evaluate two novel analytical routines for the simultaneous determination of the chemical and Si stable isotope composition (δ(30)Si) on the micrometre scale in geological samples. In both routines, multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) is combined with femtosecond-LA, where stable isotope ratios are corrected for mass bias using standard-sample-bracketing with matrix-independent calibration. The first method is based on laser ablation split stream (LASS), where the laser aerosol is split and introduced simultaneously into both the MC-ICP-MS and a quadrupole ICP-MS. The second method is based on optical emission spectroscopy using direct observation of the MC-ICP-MS plasma (LA-MC-ICP-MS|OES). Both methods are evaluated using international geological reference materials. Accurate and precise Si isotope ratios were obtained with an uncertainty typically better than 0.23‰, 2SD, δ(30)Si. With both methods major element concentrations (e.g., Na, Al, Si, Mg, Ca) can be simultaneously determined. However, LASS-ICP-MS is superior over LA-MC-ICP-MS|OES, which is limited by its lower sensitivity. Moreover, LASS-ICP-MS offers trace element analysis down to the μg g(-1)-range for more than 28 elements due to lower limits of detection, and with typical uncertainties better than 15%. For in situ simultaneous stable isotope measurement and chemical composition analysis LASS-ICP-MS in combination with MC-ICP-MS is the method of choice. Copyright © 2016 Elsevier B.V. All rights reserved.
Evolution of laser skin resurfacing: from scanning to fractional technology.
Aslam, Arif; Alster, Tina S
2014-11-01
Laser skin resurfacing was popularized for photoaged and scarred skin 2 decades ago. Since then, several technologic advancements have led to a new generation of delivery systems that produce excellent clinical outcomes with reduced treatment risks and faster recovery times. To review the evolution of laser skin resurfacing from pulsed and scanned infrared laser technology to the latest techniques of nonablative and ablative fractional photothermolysis. All published literature regarding laser skin resurfacing was analyzed and collated. A comprehensive review of laser skin resurfacing was outlined and future developments in the field of fractionated laser skin treatment were introduced. Laser skin resurfacing has evolved such that excellent clinical outcomes in photodamaged and scarred skin are achieved with rapid wound healing. As newer devices are developed, the applications of this technology will have a dramatic effect on the delivery of medical and aesthetic dermatology.
Shahabi, Sima; Chiniforush, Nasim; Bahramian, Hoda; Monzavi, Abbas; Baghalian, Ali; Kharazifard, Mohammad Javad
2013-01-01
The purpose of this study was to evaluate the effect of Er:YAG and Er,Cr:YSGG laser on tensile bond strength of composite resin to dentine in comparison with bur-prepared cavities. Fifteen extracted caries-free human third molars were selected. The teeth were cut at a level below the occlusal pit and fissure plan and randomly divided into three groups. Five cavities were prepared by diamond bur, five cavities prepared by Er:YAG laser, and the other group prepared by Er,Cr:YSGG laser. Then, all the cavities were restored by composite resin. The teeth were sectioned longitudinally with Isomet and the specimens prepared in dumbbelled shape (n = 36). The samples were attached to special jigs, and the tensile bond strength of the three groups was measured by universal testing machine at a speed of 0.5 mm/min. The results of the three groups were analyzed with one-way ANOVA and Tamhane test. The means and standard deviations of tensile bond strength of bur-cut, Er:YAG laser-ablated, and Er,Cr:YSGG laser-ablated dentine were 5.04 ± 0.93, 13.37 ± 3.87, and 4.85 ± 0.93 MPa, respectively. There is little difference in tensile bond strength of composite resin in Er,Cr:YSGG lased-prepared cavities in comparison with bur-prepared cavities, but the Er:YAG laser group showed higher bond strength than the other groups.
CMB-13 research on carbon and graphite
NASA Technical Reports Server (NTRS)
Smith, M. C.
1972-01-01
Preliminary results of the research on carbon and graphite accomplished during this report period are presented. Included are: particle characteristics of Santa Maria fillers, compositions and density data for hot-molded Santa Maria graphites, properties of hot-molded Santa Maria graphites, and properties of hot-molded anisotropic graphites. Ablation-resistant graphites are also discussed.
NASA Astrophysics Data System (ADS)
Stepak, Bogusz D.; Antończak, Arkadiusz J.; Szustakiewicz, Konrad; Pezowicz, Celina; Abramski, Krzysztof M.
2016-03-01
The main advantage of laser processing is a non-contact character of material removal and high precision attainable thanks to low laser beam dimensions. This technique enables forming a complex, submillimeter geometrical shapes such as vascular stents which cannot be manufactured using traditional techniques e.g. injection moulding or mechanical treatment. In the domain of nanosecond laser sources, an ArF excimer laser appears as a good candidate for laser micromachining of bioresorbable polymers such as poly(L-lactide). Due to long pulse duration, however, there is a risk of heat diffusion and accumulation in the material. In addition, due to short wavelength (193 nm) photochemical process can modify the chemical composition of ablated surfaces. The motivation for this research was to evaluate the influence of laser micromachining on physicochemical properties of poly(L-lactide). We performed calorimetric analysis of laser machined samples by using differential scanning calorimetry (DSC). It allowed us to find the optimal process parameters for heat affected zone (HAZ) reduction. The chemical composition of the ablated surface was investigated by FTIR in attenuated total reflectance (ATR) mode.
Parsiegla, Goetz; Shrestha, Bindesh; Carrière, Frédéric; Vertes, Akos
2012-01-03
Due to their significance in energy and environmental and natural product research, as well as their large genetic diversity, rapid in situ analysis of cyanobacteria is of increasing interest. Metabolic profiles and the composition of energy harvesting antenna protein complexes are needed to understand how environmental factors affect the functioning of these microorganisms. Here, we show that laser ablation electrospray ionization (LAESI) mass spectrometry enables the direct analysis of phycobilisomal antenna proteins and report on numerous metabolites from intact cyanobacteria. Small populations (n < 616 ± 76) of vegetative Anabaena sp. PCC7120 cyanobacterial cells are analyzed by LAESI mass spectrometry. The spectra reveal the ratio of phycocyanin (C-PC) and allophycocyanin (APC) in the antenna complex, the subunit composition of the phycobiliproteins, and the tentative identity of over 30 metabolites and lipids. Metabolites are tentatively identified by accurate mass measurements, isotope distribution patterns, and literature searches. The rapid simultaneous analysis of abundant proteins and diverse metabolites enables the evaluation of the environmental response and metabolic adaptation of cyanobacteria and other microorganisms. © 2011 American Chemical Society
NASA Astrophysics Data System (ADS)
Kent, A. J.; Ungerer, C. A.
2003-12-01
Light lithophile (B, Be, Li) and alkali elements (Rb, Cs) provide many constraints on the origin and evolution of primitive magmatic rocks. However these elements are often present at low abundances, requiring large sample volumes, and may be strongly effected by alteration or sample contamination. We have developed a technique for rapid, in-situ, analysis of B, Be, Li, Rb and Cs abundances in glasses, glass inclusions and minerals using laser ablation microsampling and analysis by magnetic sector ICP-MS. By coupling the high sensitivity, dynamic range and low backgrounds of the ICP-MS with the speed and minimal sample preparation requirements of laser ablation, we can analyze these elements with detection limits that rival many solution-based techniques in ~60 s and using << 200 ng of material. Analyses are conducted using a NewWave DUV 193 nm ArF Excimer laser system, with He carrier gas. Samples were ablated at energies of 10-12 mJ/cm2 with pulse rates between 2-5 hz, and by either translating a 50 μ m laser spot over the surface at a rate of 5 μ m/s or by maintaining a stationary 50-70 μ m spot. Ablated material was analyzed with a VG Axiom single collector ICP-MS using a high-sensitivity sampler cone. All peaks were checked at high mass resolving power for molecular interferences, and analyses were conducted at low resolving power to maximize transmission. Careful monitoring of backgrounds was required for low-abundance measurements. Calculated detection limits are 1-2 ppb (Cs, Be), 5-10 ppb (Li) and 15-20 ppb (B, Rb). Surface contamination was removed with a pre-analysis ablation pass, and the small size of the laser spot allowed us to avoid altered and devitrified areas. Analysis of standard glasses showed excellent agreement with accepted values and repeat analyses suggest external errors are typically < 5-10%. Glasses from the Lau Basin show strong enrichments in B, Rb and Cs that correlate with a slab-fluid signature. B, Be Rb and Cs contents are very low in MORB-like samples from the north of the basin but are enriched in evolved lavas from propagating ridge tips.
Casner, A.; Masse, L.; Delorme, B.; ...
2014-12-01
Understanding and mitigating hydrodynamic instabilities and the fuel mix are the key elements for achieving ignition in Inertial Confinement Fusion. Cryogenic indirect-drive implosions on the National Ignition Facility have evidenced that the ablative Rayleigh-Taylor Instability (RTI) is a driver of the hot spot mix. This motivates the switch to a more flexible higher adiabat implosion design [O. A. Hurricane et al., Phys. Plasmas 21, 056313 (2014)]. The shell instability is also the main candidate for performance degradation in low-adiabat direct drive cryogenic implosions [Goncharov et al., Phys. Plasmas 21, 056315 (2014)]. This paper reviews recent results acquired in planar experimentsmore » performed on the OMEGA laser facility and devoted to the modeling and mitigation of hydrodynamic instabilities at the ablation front. In application to the indirect-drive scheme, we describe results obtained with a specific ablator composition such as the laminated ablator or a graded-dopant emulator. In application to the direct drive scheme, we discuss experiments devoted to the study of laser imprinted perturbations with special phase plates. The simulations of the Richtmyer-Meshkov phase reversal during the shock transit phase are challenging, and of crucial interest because this phase sets the seed of the RTI growth. Recent works were dedicated to increasing the accuracy of measurements of the phase inversion. We conclude by presenting a novel imprint mitigation mechanism based on the use of underdense foams. Lastly, the foams induce laser smoothing by parametric instabilities thus reducing the laser imprint on the CH foil.« less
Consensus for the Treatment of Varicose Vein with Radiofrequency Ablation
Joh, Jin Hyun; Kim, Woo-Shik; Jung, In Mok; Park, Ki-Hyuk; Lee, Taeseung; Kang, Jin Mo
2014-01-01
The objective of this paper is to introduce the schematic protocol of radiofrequency (RF) ablation for the treatment of varicose veins. Indication: anatomic or pathophysiologic indication includes venous diameter within 2–20 mm, reflux time ≥0.5 seconds and distance from the skin ≥5 mm or subfascial location. Access: it is recommended to access at or above the knee joint for great saphenous vein and above the mid-calf for small saphenous vein. Catheter placement: the catheter tip should be placed 2.0 cm inferior to the saphenofemoral or saphenopopliteal junction. Endovenous heat-induced thrombosis ≥class III should be treated with low-molecular weight heparin. Tumescent solution: the composition of solution can be variable (e.g., 2% lidocaine 20 mL+500 mL normal saline+bicarbonate 2.5 mL with/without epinephrine). Infiltration can be done from each direction. Ablation: two cycles’ ablation for the first proximal segment of saphenous vein and the segment with the incompetent perforators is recommended. The other segments should be ablated one time. During RF energy delivery, it is recommended to apply external compression. Concomitant procedure: It is recommended to do simultaneously ambulatory phlebectomy. For sclerotherapy, it is recommended to defer at least 2 weeks. Post-procedural management: post-procedural ambulation is encouraged to reduce the thrombotic complications. Compression stocking should be applied for at least 7 days. Minor daily activity is not limited, but strenuous activities should be avoided for 2 weeks. It is suggested to take showers after 24 hours and tub baths, swimming, or soaking in water after 2 weeks. PMID:26217628
High temperature ablation of kaolinite layered silicate/phenolic resin/asbestos cloth nanocomposite.
Bahramian, Ahmad Reza; Kokabi, Mehrdad; Famili, Mohammad Hossein Navid; Beheshty, Mohammad Hossein
2008-01-15
The successful return of re-entry space vehicle, which is subjected to severe aerodynamic heating, is largely accompanied by some provisions to reduce the heat transfer to the structure. Heat shield is the best protection means which undergoes physical, chemical, and mostly endothermal transformations. The objective of this work is to investigate the ablating, charring, and thermal degradation behaviour of heat shield resol-type phenolic resin/kaolinite/asbestos cloth nanocomposite by oxyacetylene flame test with an external heat flux of 8 x 10(9)W/m(2) and 3000 K hot gas temperature and thermal analyzer techniques. Kinetic parameters of thermal degradation and temperature distribution at the back surface of the nanocomposite heat shield were determined and compared with that of composite counterpart.
Temporalis myofascial flap for primary cranial base reconstruction after tumor resection.
Eldaly, Ahmed; Magdy, Emad A; Nour, Yasser A; Gaafar, Alaa H
2008-07-01
To evaluate the use of the temporalis myofascial flap in primary cranial base reconstruction following surgical tumor ablation and to explain technical issues, potential complications, and donor site consequences along with their management. Retrospective case series. Tertiary referral center. Forty-one consecutive patients receiving primary temporalis myofascial flap reconstructions following cranial base tumor resections in a 4-year period. Flap survival, postoperative complications, and donor site morbidity. Patients included 37 males and 4 females ranging in age from 10 to 65 years. Two patients received preoperative and 18 postoperative radiation therapy. Patient follow-up ranged from 4 to 39 months. The whole temporalis muscle was used in 26 patients (63.4%) and only part of a coronally split muscle was used in 15 patients (36.6%). Nine patients had primary donor site reconstruction using a Medpor((R)) (Porex Surgical, Inc., Newnan, GA) temporal fossa implant; these had excellent aesthetic results. There were no cases of complete flap loss. Partial flap dehiscence was seen in six patients (14.6%); only two required surgical débridement. None of the patients developed cerebrospinal leaks or meningitis. One patient was left with complete paralysis of the temporal branch of the facial nerve. Three patients (all had received postoperative irradiation) developed permanent trismus. The temporalis myofascial flap was found to be an excellent reconstructive alternative for a wide variety of skull base defects following tumor ablation. It is a very reliable, versatile flap that is usually available in the operative field with relatively low donor site aesthetic and functional morbidity.
NASA Astrophysics Data System (ADS)
Cappelli, E.; Bellucci, A.; Orlando, S.; Trucchi, D. M.; Mezzi, A.; Valentini, V.
2013-08-01
Tungsten carbide, WC, contacts behave as very reliable Schottky contacts for opto-electronic diamond devices. Diamond is characterized by superior properties in high-power, high frequency and high-temperature applications, provided that thermally stable electrode contacts will be realized. Ohmic contacts can be easily achieved by using carbide-forming metals, while is difficult to get stable Schottky contacts at elevated temperatures, due to the interface reaction and/or inter-diffusion between metals and diamond. Novel type of contacts, made of tungsten carbide, WC, seem to be the best solution, for their excellent thermal stability, high melting point, oxidation and radiation resistance and good electrical conductivity. Our research was aimed at using pulsed laser deposition for WC thin film deposition, optimizing experimental parameters, to obtain a final device characterized by excellent electronic properties, as a detector for radiation in deep UV or as X-ray dosimeter. We deposited our films by laser ablation from a target of pure WC, using different reaction conditions (i.e., substrate heating, vacuum or reactive atmosphere (CH4/Ar), RF plasma activated), to optimize both the stoichiometry of the film and its structure. Trying to obtain a material with the best electronic response, we used also two sources of laser radiation for target ablation, i.e., nano-second pulsed excimer laser ArF, and ultra-short fs Ti:Sapphire laser. The structure and chemical aspects have been evaluated by Raman and X-ray photoelectron spectroscopy (XPS), while the dosimeter photodiode response has been tested by the I-V measurements, under soft X-ray irradiation.
NASA Astrophysics Data System (ADS)
Fisher, Christopher M.; Vervoort, Jeffrey D.
2018-04-01
Southern West Greenland contains some of the best-studied and best-preserved magmatic Eoarchean rocks on Earth, and these provide an excellent vantage point from which to view long-standing questions regarding the growth of the earliest continental crust. In order to address the questions surrounding early crustal growth and complementary mantle depletion, we present Laser Ablation Split Stream (LASS) analyses of the U-Pb and Hf isotope compositions of zircon from eleven samples of the least-altered meta-igneous rocks from the Itsaq (Amîtsoq) Gneisses of the Isukasia and Nuuk regions of southern West Greenland. This analytical technique allows a less ambiguous approach to determining the age and Hf isotope composition of complicated zircon. Results corroborate previous findings that Eoarchean zircon from the Itsaq Gneiss (∼3.85 Ga to ∼3.63 Ga) were derived from a broadly chondritic source. In contrast to the Sm-Nd whole rock isotope record for southern West Greenland, the zircon Lu-Hf isotope record provides no evidence for early mantle depletion, nor does it suggest the presence of crust older than ∼3.85 Ga in Greenland. Utilizing LASS U-Pb and Hf data from the Greenland zircons studied here, we demonstrate the importance of focusing on the magmatic (rather than detrital) zircon record to more confidently understand early crustal growth and mantle depletion. We compare the Greenland Hf isotope data with other Eoarchean magmatic complexes such as the Acasta Gneiss Complex, Nuvvuagittuq greenstone belt, and the gneissic complexes of southern Africa, and all lack zircons with suprachondritic Hf isotope compositions. In total, these data suggest only a very modest volume of crust was produced during (or survived from) the Hadean and earliest Eoarchean. There remains no record of planet-scale early Earth mantle depletion in the Hf isotope record prior to 3.8 Ga.
Evaluation of pressure in a plasma produced by laser ablation of steel
NASA Astrophysics Data System (ADS)
Hermann, Jörg; Axente, Emanuel; Craciun, Valentin; Taleb, Aya; Pelascini, Frédéric
2018-05-01
We investigated the time evolution of pressure in the plume generated by laser ablation with ultraviolet nanosecond laser pulses in a near-atmospheric argon atmosphere. These conditions were previously identified to produce a plasma of properties that facilitate accurate spectroscopic diagnostics. Using steel as sample material, the present investigations benefit from the large number of reliable spectroscopic data available for iron. Recording time-resolved emission spectra with an echelle spectrometer, we were able to perform accurate measurements of electron density and temperature over a time interval from 200 ns to 12 μs. Assuming local thermodynamic equilibrium, we computed the plasma composition within the ablated vapor material and the corresponding kinetic pressure. The time evolution of plume pressure is shown to reach a minimum value below the pressure of the background gas. This indicates that the process of vapor-gas interdiffusion has a negligible influence on the plume expansion dynamics in the considered timescale. Moreover, the results promote the plasma pressure as a control parameter in calibration-free laser-induced breakdown spectroscopy.
NASA Astrophysics Data System (ADS)
Harris, C. D.; Profeta, Luisa T. M.; Akpovo, Codjo A.; Johnson, Lewis; Stowe, Ashley C.
2017-05-01
A calibration model was created to illustrate the detection capabilities of laser ablation molecular isotopic spectroscopy (LAMIS) discrimination in isotopic analysis. The sample set contained boric acid pellets that varied in isotopic concentrations of 10B and 11B. Each sample set was interrogated with a Q-switched Nd:YAG ablation laser operating at 532 nm. A minimum of four band heads of the β system B2∑ -> Χ2∑transitions were identified and verified with previous literature on BO molecular emission lines. Isotopic shifts were observed in the spectra for each transition and used as the predictors in the calibration model. The spectra along with their respective 10/11B isotopic ratios were analyzed using Partial Least Squares Regression (PLSR). An IUPAC novel approach for determining a multivariate Limit of Detection (LOD) interval was used to predict the detection of the desired isotopic ratios. The predicted multivariate LOD is dependent on the variation of the instrumental signal and other composites in the calibration model space.
Thermochemical Ablation Analysis of the Orion Heatshield
NASA Technical Reports Server (NTRS)
Sixel, William
2015-01-01
The Orion Multi-Purpose Crew Vehicle will one day carry astronauts to the Moon and beyond, and Orion's heatshield is a critical component in ensuring their safe return to Earth. The Orion heatshield is the structural component responsible for absorbing the intense heating environment caused by re-entry to Earth's atmosphere. The heatshield is primarily composed of Avcoat, an ablative material that is consumed during the re-entry process. Ablation is primarily characterized by two processes: pyrolysis and recession. The decomposition of in-depth virgin material is known as pyrolysis. Recession occurs when the exposed surface of the heatshield reacts with the surrounding flow. The Orion heatshield design was changed from an individually filled Avcoat honeycomb to a molded block Avcoat design. The molded block Avcoat heatshield relies on an adhesive bond to keep it attached to the capsule. In some locations on the heatshield, the integrity of the adhesive bond cannot be verified. For these locations, a mechanical retention device was proposed. Avcoat ablation was modelled in CHAR and the in-depth virgin material temperatures were used in a Thermal Desktop model of the mechanical retention device. The retention device was analyzed and shown to cause a large increase in the maximum bondline temperature. In order to study the impact of individual ablation modelling parameters on the heatshield sizing process, a Monte Carlo simulation of the sizing process was proposed. The simulation will give the sensitivity of the ablation model to each of its input parameters. As part of the Monte Carlo simulation, statistical uncertainties on material properties were required for Avcoat. Several properties were difficult to acquire uncertainties for: the pyrolysis gas enthalpy, non-dimensional mass loss rate (B´c), and Arrhenius equation parameters. Variability in the elemental composition of Avcoat was used as the basis for determining the statistical uncertainty in pyrolysis gas enthalpy and B´c. A MATLAB program was developed to allow for faster, more accurate and automated computation of Arrhenius reaction parameters. These parameters are required for a material model to be used in the CHAR ablation analysis program. This MATLAB program, along with thermogravimetric analysis (TGA) data, was used to generate uncertainties on the Arrhenius parameters for Avcoat. In addition, the TGA fitting program was developed to provide Arrhenius parameters for the ablation model of the gap filler material, RTV silicone.
Experimental determination of ablation vapor species from carbon phenolic heat-shield materials
NASA Technical Reports Server (NTRS)
Lincoln, K. A.
1981-01-01
The relative concentrations of vapors produced from carbon phenolic composites under thermal loadings approximating those expected at peak heating during vehicle entry into the atmospheres of the outer planets have been determined. The technique of vaporizing the surface of bulk samples by laser irradiation while measuring in situ the vapor species by mass spectrometry is described. Results show that vapor composition varies with irradiance level and with depth of heating (or extent of pyrolysis). Attempts are made to compare these experimental results with the theoretical predictions from computer codes.
Multilayer Impregnated Fibrous Thermal Insulation Tiles
NASA Technical Reports Server (NTRS)
Tran, Huy K.; Rasky, Daniel J.; Szalai, Christine e.; Hsu, Ming-ta; Carroll, Joseph A.
2007-01-01
The term "secondary polymer layered impregnated tile" ("SPLIT") denotes a type of ablative composite-material thermal- insulation tiles having engineered, spatially non-uniform compositions. The term "secondary" refers to the fact that each tile contains at least two polymer layers wherein endothermic reactions absorb considerable amounts of heat, thereby helping to prevent overheating of an underlying structure. These tiles were invented to afford lighter-weight alternatives to the reusable thermal-insulation materials heretofore variously used or considered for use in protecting the space shuttles and other spacecraft from intense atmospheric-entry heating.
NASA Astrophysics Data System (ADS)
Kranzbühler, Benedikt; Gross, Oliver; Fankhauser, Christian D.; Hefermehl, Lukas J.; Poyet, Cédric; Largo, Remo; Müntener, Michael; Seifert, Hans-Helge; Zimmermann, Matthias; Sulser, Tullio; Müller, Alexander; Hermanns, Thomas
2012-02-01
Introduction and objectives: Greenlight laser vaporization (LV) of the prostate is characterized by simultaneous vaporization and coagulation of prostatic tissue resulting in tissue ablation together with excellent hemostasis during the procedure. It has been reported that bipolar plasma vaporization (BPV) of the prostate might be an alternative for LV. So far, it has not been shown that BPV is as effective as LV in terms of tissue ablation or hemostasis. We performed transrectal three-dimensional ultrasound investigations to compare the efficiency of tissue ablation between LV and BPV. Methods: Between 11.2009 and 5.2011, 50 patients underwent pure BPV in our institution. These patients were matched with regard to the pre-operative prostate volume to 50 LV patients from our existing 3D-volumetry-database. Transrectal 3D ultrasound and planimetric volumetry of the prostate were performed pre-operatively, after catheter removal, 6 weeks and 6 months. Results: Median pre-operative prostate volume was not significantly different between the two groups (45.3ml vs. 45.4ml; p=1.0). After catheter removal, median absolute volume reduction (BPV 12.4ml, LV 6.55ml) as well as relative volume reduction (27.8% vs. 16.4%) were significantly higher in the BPV group (p<0.001). After six weeks (42.9% vs. 33.3%) and six months (47.2% vs. 39.7%), relative volume reduction remained significantly higher in the BPV group (p<0.001). Absolute volume reduction was non-significantly higher in the BPV group after six weeks (18.4ml, 13.8ml; p=0.051) and six months (20.8ml, 18ml; p=0.3). Clinical outcome parameters improved significantly in both groups without relevant differences between the groups. Conclusions: Both vaporization techniques result in efficient tissue ablation with initial prostatic swelling. BPV seems to be superior due to a higher relative volume reduction. This difference had no clinical impact after a follow-up of 6M.
NASA Astrophysics Data System (ADS)
Nikolov, A. S.; Balchev, I. I.; Nedyalkov, N. N.; Kostadinov, I. K.; Karashanova, D. B.; Atanasova, G. B.
2017-11-01
Nanostructures of noble metal were produced by pulsed laser ablation in liquid. A solid Ag target was immersed in double distilled water and a CuBr laser in a master oscillator—power amplifier configuration oscillating at 511 nm and emitting pulses with duration of 30 ns at a repetition rate of up to 20 kHz was employed to produce different colloids. The impact was studied of the laser pulse repetition rate and the beam scanning speed on the morphology of the nanostructures formed. Further, the optical extinction spectra of the colloids in the UV/VIS range were measured and used to make an indirect assessment of the changes in the shape and size distribution of the nanostructures. The transmission values in the near UV range were used to estimate the efficiency of the ablation process under the different experimental conditions implemented. A visualization of the nanostructures was made possible by transmission electron microscopy (TEM). The structure and phase composition of the nanoparticles were studied by high-resolution transmission electron microscopy (HRTEM) and selected area electron diffraction (SAED), while the alteration of the target surface caused by the impact of the high-repetition-rate laser illumination was investigated by X-ray photoelectron spectroscopy (XPS). The optimal conditions were determined yielding the highest efficiency in terms of amount of ablated material.
In Situ Carbon Isotope Analysis by Laser Ablation MC-ICP-MS.
Chen, Wei; Lu, Jue; Jiang, Shao-Yong; Zhao, Kui-Dong; Duan, Deng-Fei
2017-12-19
Carbon isotopes have been widely used in tracing a wide variety of geological and environmental processes. The carbon isotope composition of bulk rocks and minerals was conventionally analyzed by isotope ratio mass spectrometry (IRMS), and, more recently, secondary ionization mass spectrometry (SIMS) has been widely used to determine carbon isotope composition of carbon-bearing solid materials with good spatial resolution. Here, we present a new method that couples a RESOlution S155 193 nm laser ablation system with a Nu Plasma II MC-ICP-MS, with the aim of measuring carbon isotopes in situ in carbonate minerals (i.e., calcite and aragonite). Under routine operating conditions for δ 13 C analysis, instrumental bias generally drifts by 0.8‰-2.0‰ in a typical analytical session of 2-3 h. Using a magmatic calcite as the standard, the carbon isotopic composition was determined for a suite of calcite samples with δ 13 C values in the range of -6.94‰ to 1.48‰. The obtained δ 13 C data are comparable to IRMS values. The combined standard uncertainty for magmatic calcite is <0.3‰ (1s). No significant matrix effects have been identified in calcite with the amplitude of chemical composition variation (i.e., MnO, SrO, MgO, or FeO) up to 2.5 wt %. Two modern corals were investigated using magmatic calcite as the calibration standard, and the average δ 13 C values for both corals are similar to the bulk IRMS values. Moreover, coral exhibits significant heterogeneity in carbon isotope compositions, with differences up to 4.85‰ within an individual coral. This study indicates that LA-MC-ICP-MS can serve as an appropriate method to analyze carbon isotopes of carbonate minerals in situ.
Ultrathin Tungsten Oxide Nanowires/Reduced Graphene Oxide Composites for Toluene Sensing
Hassan, Muhammad; Wang, Zhi-Hua; Huang, Wei-Ran; Li, Min-Qiang; Chen, Jia-Fu
2017-01-01
Graphene-based composites have gained great attention in the field of gas sensor fabrication due to their higher surface area with additional functional groups. Decorating one-dimensional (1D) semiconductor nanomaterials on graphene also show potential benefits in gas sensing applications. Here we demonstrate the one-pot and low cost synthesis of W18O49 NWs/rGO composites with different amount of reduced graphene oxide (rGO) which show excellent gas-sensing properties towards toluene and strong dependence on their chemical composition. As compared to pure W18O49 NWs, an improved gas sensing response (2.8 times higher) was achieved in case of W18O49 NWs composite with 0.5 wt. % rGO. Promisingly, this strategy can be extended to prepare other nanowire based composites with excellent gas-sensing performance. PMID:28961178
The effect of fibre orientation on a TWCP composite
NASA Astrophysics Data System (ADS)
Barnes, Nicholas; Wood, David; Appleby-Thomas, Gareth; Leighs, James; Roberts, Andrew; Hazell, Paul
2013-06-01
Multiple authors have shown that orientation can greatly affect the shock profiles seen in composites. Carbon fibre composites are employed in multiple sectors, with their use in the aerospace industry becoming more prevalent. An angle of 20° between the outer surface and the weave direction provides a good compromise between strength and ablation. Using a single stage gas gun with manganin pressure gauges the shock response of both a 90° and 45° layup TWCP composite were investigated up to a particle velocity of c.a. 1 mm μs-1, in both the US-up and pressure-volume plane. Comparisons in terms of shock propagation were also made with previously investigated TWCP orientations of 0° and 20° as well as other carbon fibre based composites from the literature. This allowed a detailed interrogation of the effects of weave orientation in this important TWCP composite to be made.
Energy and Mass Balance At Gran Campo Nevado, Patagonia, Chile
NASA Astrophysics Data System (ADS)
Schneider, C.; Kilian, R.; Casassa, G.
The Gran Campo Nevado (GCN) Ice Cap on Peninsula Muñoz Gamero, Chile, is lo- cated in the southernmost part of the Patagonian Andes at 53S. It comprises an ice cap and numerous outlet glaciers which mostly end in proglacial lakes at sea level. The total ice covered area sums up to approximately 250 km2. GCN forms the only major ice body between the Southern Patagonian Icefield and the Street of Magallan. Its almost unique location in the zone of the all-year westerlies makes it a region of key interest in terms of glacier and climate change studies of the westwind zone of the Southern Hemisphere. Mean annual temperature of approximately +5C at sea level and high precipitation of about 8.000 mm per year lead to an extreme turn-over of ice mass from the accumulation area of the GCN Ice Cap to the ablation areas of the outlet glaciers. Since October 1999 an automated weather station (AWS) is run continuously in the area at Bahia Bahamondes for monitoring climate parameters. From February to April 2000 an additional AWS was operated on Glaciar Lengua a small outlet glacier of GCN to the north-west. Ablation has been measured at stakes during the same pe- riod. The aim of this study, was to obtain point energy and mass balance on Glaciar Lengua. The work was conducted as part of the international and interdisciplinary working group SGran Campo NevadoT and supported by the German Research Foun- & cedil;dation (DFG). Energy balance was calculated using the bulk approach formulas and calibrated to the measured ablation. It turns out, that sensible heat transfer is the major contribution to the energy balance. Since high cloud cover rates prevail, air tempera- ture is the key factor for the energy balance of the glacier. Despite high rain fall rates, energy input from rain fall is of only minor importance to the overall energy balance. From the energy balance computed, it was possible to derive summer-time degree-day factors for Glaciar Lengua. With data from the nearby AWS at Bahia Bahamondes we computed summer ablation for the summer seasons of 1999/2000 and 2000/2001. Ablation at 45o m a.s.l. sums up to about 7 m in 1999/2000 and to 5.5 m in 2000/2001. This is in excellent accordance (+/-2%) with measurements at ablation stakes that have been drilled into the glacier on its ablation area. Surface velocity measured from the displacement of the ablation stakes is estimated to 62 m per year. A RADAR survey with ice penetrating RADAR conducted on the ablation area of Glaciar Lengua during the austral summer 2000/2001 reveals glacier depths between 120 m and 200 m ap- 1 proximately. The data sampled will allow to set up a model for mass flow and ablation at a cross-section of Glaciar Lengua at 450 m a.s.l. Glaciar Lengua has no accumu- lation area itself but obtains all of its ice mass through icefall from the heights of the GCN Ice Cap. Therefore, this model will be of fundamental importance to understand the glacial regime of the entire ice cap. 2
Spaceplane Technology and Research (STAR)
1984-08-01
autonomy, flexibility , maneuverability, responsiveness, survivability and cost- effectiveness required of military aerospace operations as the result...orbit to simulate desired trajectory. Determine the ablative behavior and its effect on trajectory for various C/C composite materials. Expected... the 747-200F would potentially be the most flexible and cost- effective launch system. The associated use of stage-stations appears especially cost
Meteoric Magnesium Ions in the Martian Atmosphere
NASA Technical Reports Server (NTRS)
Pesnell, William Dean; Grebowsky, Joseph
1999-01-01
From a thorough modeling of the altitude profile of meteoritic ionization in the Martian atmosphere we deduce that a persistent layer of magnesium ions should exist around an altitude of 70 km. Based on current estimates of the meteoroid mass flux density, a peak ion density of about 10(exp 4) ions/cm is predicted. Allowing for the uncertainties in all of the model parameters, this value is probably within an order of magnitude of the correct density. Of these parameters, the peak density is most sensitive to the meteoroid mass flux density which directly determines the ablated line density into a source function for Mg. Unlike the terrestrial case, where the metallic ion production is dominated by charge-exchange of the deposited neutral Mg with the ambient ions, Mg+ in the Martian atmosphere is produced predominantly by photoionization. The low ultraviolet absorption of the Martian atmosphere makes Mars an excellent laboratory in which to study meteoric ablation. Resonance lines not seen in the spectra of terrestrial meteors may be visible to a surface observatory in the Martian highlands.
Current Status of Fractional Laser Resurfacing.
Carniol, Paul J; Hamilton, Mark M; Carniol, Eric T
2015-01-01
Fractional lasers were first developed based on observations of lasers designed for hair transplantation. In 2007, ablative fractional laser resurfacing was introduced. The fractionation allowed deeper tissue penetration, leading to greater tissue contraction, collagen production and tissue remodeling. Since then, fractional erbium:YAG resurfacing lasers have also been introduced. These lasers have yielded excellent results in treating photoaging, acne scarring, and dyschromia. With the adjustment of microspot density, pulse duration, number of passes, and fluence, the surgeon can adjust the treatment effects. These lasers have allowed surgeons to treat patients with higher Fitzpatrick skin types (types IV to VI) and greater individualize treatments to various facial subunits. Immunohistochemical analysis has demonstrated remodeling effects of the tissues for several months, producing longer lasting results. Adjuvant treatments are also under investigation, including concomitant face-lift, product deposition, and platelet-rich plasma. Finally, there is a short recovery time from treatment with these lasers, allowing patients to resume regular activities more quickly. Although there is a relatively high safety profile for ablative fractionated lasers, surgeons should be aware of the limitations of specific treatments and the associated risks and complications.
Hard tooth tissue removal by short and long Er:YAG or Er,Cr:YSGG mid-infrared laser radiation
NASA Astrophysics Data System (ADS)
Jelínková, H.; Dostálová, T.; Remeš, M.; Šulc, J.; Němec, M.; Fibrich, M.
2017-02-01
Hard dental tissue removal by laser radiation is an alternative treatment to conventional dental-drilling procedures. The advantages of this therapy are fast and localized treatment of hard dental tissue and painlessness. The most effective systems for those purposes are Er-lasers generating radiation at wavelengths of around 3 μm. The aim of this study was qualitative and quantitative examination of human dentin and ivory tissue removal by pulsed free-running (FR) and Q-switched (QSW) Er:YAG and Er,Cr:YSGG laser radiations. From the obtained results it follows that generally Er:YAG laser has lower threshold for the tissue removal in both FR and QSW regimes. Furthermore, the FR Er:YAG and Er,Cr:YSGG radiation can be effective for both dentin and ivory ablation and can prepare smooth cavities without side effects. The QSW regime is useful preferably for precise ablation of a starting tooth defect and for the part of the tooth very close to the gum. This regime is excellent for micro-preparation or for tooth treatment of children.
Dubourg, Georges; Segkos, Apostolos; Katona, Jaroslav; Radović, Marko; Savić, Slavica; Crnojević-Bengin, Vesna
2017-01-01
This paper describes the fabrication and the characterization of an original example of a miniaturized resistive-type humidity sensor, printed on flexible substrate in a large-scale manner. The fabrication process involves laser ablation for the design of interdigitated electrodes on PET (Poly-Ethylene Terephthalate) substrate and a screen-printing process for the deposition of the sensitive material, which is based on TiO2 nanoparticles. The laser ablation process was carefully optimized to obtain micro-scale and well-resolved electrodes on PET substrate. A functional paste based on cellulose was prepared in order to allow the precise screen-printing of the TiO2 nanoparticles as sensing material on the top of the electrodes. The current against voltage (I–V) characteristic of the sensor showed good linearity and potential for low-power operation. The results of a humidity-sensing investigation and mechanical testing showed that the fabricated miniaturized sensors have excellent mechanical stability, sensing characteristics, good repeatability, and relatively fast response/recovery times operating at room temperature. PMID:28800063
Basu, Partha; Meheus, Filip; Chami, Youssef; Hariprasad, Roopa; Zhao, Fanghui; Sankaranarayanan, Rengaswamy
2017-07-01
Management algorithms for screen-positive women in cervical cancer prevention programs have undergone substantial changes in recent years. The WHO strongly recommends human papillomavirus (HPV) testing for primary screening, if affordable, or if not, then visual inspection with acetic acid (VIA), and promotes treatment directly following screening through the screen-and-treat approach (one or two clinic visits). While VIA-positive women can be offered immediate ablative treatment based on certain eligibility criteria, HPV-positive women need to undergo subsequent VIA to determine their eligibility. Simpler ablative methods of treatment such as cryotherapy and thermal coagulation have been demonstrated to be effective and to have excellent safety profiles, and these have become integral parts of new management algorithms. The challenges faced by low-resource countries are many and include, from the management perspective, identifying an affordable point-of-care HPV detection test, minimizing over-treatment, and installing an effective information system to ensure high compliance to treatment and follow-up. © 2017 The Authors. International Journal of Gynecology & Obstetrics published by John Wiley & Sons Ltd on behalf of International Federation of Gynecology and Obstetrics.
Isotopic Analysis of Uranium in NIST SRM Glass by Femtosecond Laser Ablation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duffin, Andrew M.; Hart, Garret L.; Hanlen, Richard C.
We employed femtosecond Laser Ablation Multicollector Inductively Coupled Mass Spectrometry for the 11 determination of uranium isotope ratios in a series of standard reference material glasses (NIST 610, 612, 614, and 12 616). This uranium concentration in this series of SRM glasses is a combination of isotopically natural uranium in 13 the materials used to make the glass matrix and isotopically depleted uranium added to increase the uranium 14 elemental concentration across the series. Results for NIST 610 are in excellent agreement with literature values. 15 However, other than atom percent 235U, little information is available for the remaining glasses.more » We present atom 16 percent and isotope ratios for 234U, 235U, 236U, and 238U for all four glasses. Our results show deviations from the 17 certificate values for the atom percent 235U, indicating the need for further examination of the uranium isotopes in 18 NIST 610-616. Our results are fully consistent with a two isotopic component mixing between the depleted 19 uranium spike and natural uranium in the bulk glass.« less
Knuckle Pads—A common problem but good to treat by Laser
NASA Astrophysics Data System (ADS)
Herold, Manfred; Russe-Wilflingseder, Katharina
2010-05-01
Knuckle pads are common skin lesions not disease associated and seen as thickended skin like nodules situated usually on the dorsal site of the proximal interphalangeal joints. Neither medical nor surgical procedures are very effective to remove knuckle pads. A women 22 years of age with knuckle pads on the fingers two and three on both hands which reoccurred after surgical resections was successful treated with a long pulsed Erbium:YAG laser. All four fingers were ablated within one single treatment. The aesthetic result was excellent and lasted at least for 18 months.
D'Amato, Roberto; Petrelli, Maurizio; Proietti, Primo; Onofri, Andrea; Regni, Luca; Perugini, Diego; Businelli, Daniela
2018-03-25
Biofortification of food crops has been used to increase the intake of Se in the human diet, even though this may change the concentration of other elements and modify the nutritional properties of the enriched food. Selenium biofortification programs should include routine assessment of the overall mineral composition of enriched plants. Laser ablation inductively coupled plasma mass spectrometry (LA ICP-MS) was used for the assessment of mineral composition of table olives. Olive trees were fertilized with sodium selenate before flowering. At harvest, the edible parts of drupes proved to be significantly enriched in Se, delivering 6.1 μg g -1 (39% of the RDA for five olives). Such enrichment was followed by significant changes in the concentrations of B, Mg, K, Cr, Mn, Fe and Cu in edible parts, which are discussed for their impact on food quality. The biofortification of olive plants has allowed the enrichment of fruits with selenium. Enrichment with selenium has caused an increase in the concentration of other elements, which can change the nutritional quality of the drupes. The analytical technique used well as a valuable tool for routinely determining the chemical composition of all fruit parts. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.
NASA Astrophysics Data System (ADS)
Brusberg, Lars; Neitz, Marcel; Schröder, Henning; Fricke-Begemann, Thomas; Ihlemann, Jürgen
2014-03-01
The future need for more bandwidth forces the development of optical transmission solutions for rack-to-rack, boardto- board and chip-to-chip interconnects. The goals are significant reduction of power consumption, highest density and potential for bandwidth scalability to overcome the limitations of the systems today with mostly copper based interconnects. For system integration the enabling of thin glass as a substrate material for electro-optical components with integrated micro-optics for efficient light coupling to integrated optical waveguides or fibers is becoming important. Our glass based packaging approach merges micro-system packaging and glass integrated optics. This kind of packaging consists of a thin glass substrate with integrated micro lenses providing a platform for photonic component assembly and optical fiber or waveguide interconnection. Thin glass is commercially available in panel and wafer size and characterizes excellent optical and high frequency properties. That makes it perfect for microsystem packaging. A suitable micro lens approach has to be comparable with different commercial glasses and withstand post-processing like soldering. A benefit of using laser ablated Fresnel lenses is the planar integration capability in the substrate for highest integration density. In the paper we introduce our glass based packaging concept and the Fresnel lens design for different scenarios like chip-to-fiber, chip-to-optical-printed-circuit-board coupling. Based on the design the Fresnel lenses were fabricated by using a 157 nm fluorine laser ablation system.
NASA Astrophysics Data System (ADS)
Becker, J. Sabine
2005-04-01
For a few years now inductively coupled plasma mass spectrometry has been increasingly used for precise and accurate determination of isotope ratios of long-lived radionuclides at the trace and ultratrace level due to its excellent sensitivity, good precision and accuracy. At present, ICP-MS and also laser ablation ICP-MS are applied as powerful analytical techniques in different fields such as the characterization of nuclear materials, recycled and by-products (e.g., spent nuclear fuel or depleted uranium ammunitions), radioactive waste control, in environmental monitoring and in bioassay measurements, in health control, in geochemistry and geochronology. Especially double-focusing sector field ICP mass spectrometers with single ion detector or with multiple ion collector device have been used for the precise determination of long-lived radionuclides isotope ratios at very low concentration levels. Progress has been achieved by the combination of ultrasensitive mass spectrometric techniques with effective separation and enrichment procedures in order to improve detection limits or by the introduction of the collision cell in ICP-MS for reducing disturbing interfering ions (e.g., of 129Xe+ for the determination of 129I). This review describes the state of the art and the progress of ICP-MS and laser ablation ICP-MS for isotope ratio measurements of long-lived radionuclides in different sample types, especially in the main application fields of characterization of nuclear and radioactive waste material, environmental research and health controls.
NASA Astrophysics Data System (ADS)
Guan, Yiwen; Li, Jiang; Liu, Yang
2017-07-01
Current understanding of the physical and chemical processes involved in the ablation of insulation materials by highly aluminized solid propellants is limited. The study on the heat transfer and ablation principle of ethylene propylene diene monomer (EPDM) materials under slag deposition condition is essential for future design or modification of large solid rocket motors (SRMs) for launch application. In this paper, the alumina liquid flow pattern and the deposition principle in full-scale SRM engines are discussed. The interaction mechanism between the alumina droplets and the wall are analyzed. Then, an experimental method was developed to simulate the insulation material ablation under slag deposition condition. Experimental study was conducted based on a laboratory-scale device. Meanwhile, from the analysis of the cross-sectional morphology and chemical composition of the charring layer after ablation, the reaction mechanism of the charring layer under deposition condition was discussed, and the main reaction equation was derived. The numerical simulation and experimental results show the following. (i) The alumina droplet flow in the deposition section of the laboratory-scale device is similar to that of a full-scale SRM. (ii) The charring layer of the EPDM insulator displays a porous tight/loose structure under high-temperature slag deposition condition. (iii) A seven-step carbothermal reduction in the alumina is derived and established under high-pressure and high-temperature environment in the SRM combustion chamber. (iv) The analysis using thermodynamic software indicates that the reaction of the alumina and charring layer initially forms Al4C3 during the operation. Then, Al element and Al2OC compound are subsequently produced with the reduction in the release of gas CO as well with continuous environmental heating.
NASA Astrophysics Data System (ADS)
Tulej, Marek; Neubeck, Anna; Ivarsson, Magnus; Brigitte Neuland, Maike; Riedo, Andreas; Wurz, Peter
2015-04-01
Search for signatures of life on other planets is one of the most important goals of current planetary missions. Among various possible biomarkers, which can be investigated in situ on planetary surfaces, the detection of bio-relevant elements in planetary materials is of considerable interest and the abundance of isotopes can be important signatures of past and present bioactivities [1, 2]. We investigate the chemical composition of fossilised biological inclusions embedded in a carbonate host phase by a miniature laser ablation mass spectrometer (LMS) [3]. The LMS instrument combines a laser ablation ion source for ablation, atomisation and ionisation of surface material with a reflectron time-of-flight (TOF) mass spectrometer. LMS delivers mass spectra of almost all elements and their isotopes. In the current setup a fs-laser ablation ion source is applied with high lateral (15 um) and vertical (sub-um) resolution [4, 7] and the mass analyser supports mass resolution of 400-500 (at 56Fe mass peak) and dynamic range of eight orders of magnitude [5, 6]. From the 200 mass spectra recorded at 200 different locations on the carbonate sample surface, five mass spectra were identified which recorded the chemical composition of inclusions; from the other mass spectra the composition of the carbonate host matrix could be determined. The microscopic inspection of the sample surface and correlation with the coordinates of the laser ablation measurements made the confirmation to the location of the inclusion [8]. For the carbonate host matrix, the mass spectrometric analysis yielded the major elements H, C, O, Na, Mg, K and Ca and the trace elements Li, B and Cl. The measurements at the inclusion locations yielded in addition, the detection of F, Si, P, S, Mn, Fe, Ni, Co and Se. For most of the major elements the isotope ratios were found to be conform to the terrestrial values within a few per mills, while for minor and trace elements the determination of isotope ratios were less accurate due to low signal to noise ratios (SNR). The isotope abundances for the lightest isotope of B, S were observed to be larger than terrestrial, which is consistent with isotope fractionation by bio-relevant processes and a salty ocean. The studies demonstrates the current performance of the miniature LMS for in situ investigation of highly heterogeneous samples and its capabilities for the identification of fossilised biological matter. References: [1] Summons et al., Astrobiology, 11, 157, 2011. [2] Wurz et al., Sol. Sys. Res. 46 408, 2012. [3] Rohner et al.,Meas. Sci. Technol., 14, 2159, 2003. [4] Riedo et al., J. Anal. Atom. Spectrom. 28, 1256, 2013. [5] Riedo et al., J. Mass Spectrom.48, 1, 2013. [6] Neuland et al., Planet. Space. Sci. 101, 196, 2014. [7] Grimaudo et al., Anal. Chem. 2014, submitted. [8] Tulej et al. Geostand. Geoanal. Res., 2014; DOI: 10.1111/j.1751-908X.2014.00302.x
Tip-enhanced ablation and ionization mass spectrometry for nanoscale chemical analysis
Liang, Zhisen; Zhang, Shudi; Li, Xiaoping; Wang, Tongtong; Huang, Yaping; Hang, Wei; Yang, Zhilin; Li, Jianfeng; Tian, Zhongqun
2017-01-01
Spectroscopic methods with nanoscale lateral resolution are becoming essential in the fields of physics, chemistry, geology, biology, and materials science. However, the lateral resolution of laser-based mass spectrometry imaging (MSI) techniques has so far been limited to the microscale. This report presents the development of tip-enhanced ablation and ionization time-of-flight mass spectrometry (TEAI-TOFMS), using a shell-isolated apertureless silver tip. The TEAI-TOFMS results indicate the capability and reproducibility of the system for generating nanosized craters and for acquiring the corresponding mass spectral signals. Multi-elemental analysis of nine inorganic salt residues and MSI of a potassium salt residue pattern at a 50-nm lateral resolution were achieved. These results demonstrate the opportunity for the distribution of chemical compositions at the nanoscale to be visualized. PMID:29226250
Novel ternary composites: Preparation, performance and application of ZnFe2O4/TiO2/polyaniline
NASA Astrophysics Data System (ADS)
Li, Juanbi; Xiao, Qiushi; Li, Liangchao; Shen, Junhai; Hu, Diqiong
2015-03-01
A series of ZnFe2O4/TiO2/polyaniline ternary composites with excellent photocatalytic activity were successfully synthesized by chemical method. The phase composition, morphology, conductivity, electrical and magnetic performances of the as-samples were characterized by means of modern measurement technology. And the photocatalytic degradation activity tests for the samples were estimated using rhodamine B (RhB) and methyl orange (MO) as targeted pollutants. The results indicated that there existed some interactions between each component in the ternary composites, and the electrical conductivities and photocatalytic degradation activities of the ternary composites were improved due to the coating of polyaniline. Moreover, when the mass fraction of aniline was up to 50%, the ternary composite exhibited a great decontaminating (including photocatalytic degradation and adsorption) activity of on both MO and RhB and displayed an excellent reusability.
Easily Dispersible NiFe2O4/RGO Composite for Microwave Absorption Properties in the X-Band
NASA Astrophysics Data System (ADS)
Bateer, Buhe; Zhang, Jianjao; Zhang, Hongchen; Zhang, Xiaochen; Wang, Chunyan; Qi, Haiqun
2018-01-01
Composites with good dispersion and excellent microwave absorption properties have important applications. Therefore, an easily dispersible NiFe2O4/reduced graphene oxide (RGO) composite has been prepared conveniently through a simple hydrothermal method. Highly crystalline, small size (about 7 nm) monodispersed NiFe2O4 nanoparticles (NPs) are evenly distributed on the surface of RGO. The microwave absorbability revealed that the NiFe2O4/RGO composite exhibits excellent microwave absorption properties in the X-band (8-12 GHz), and the minimum reflection loss of the NiFe2O4/RGO composite is -27.7 dB at 9.2 GHz. The NiFe2O4/RGO composite has good dispersibility in nonpolar solvent, which facilitates the preparation of stable commercial microwave absorbing coatings. It can be a promising candidate for lightweight microwave absorption materials in many application fields.
Films, Preimpregnated Tapes and Composites Made from Polyimide "Salt-Like" Solutions
NASA Technical Reports Server (NTRS)
Cano, Roberto J. (Inventor); Weiser, Erik S. (Inventor); St.Clair, Terry L. (Inventor); Echigo, Yoshiaki (Inventor); Kaneshiro, Hisayasu (Inventor)
2001-01-01
High quality films, preimpregnated tape (prepegs), and composites have been fabricated from polyimide precursor 'saltlike' solutions. These salt-like solutions have a low viscosity (5,000 to 10,000 cp) and a high solids content (50-65% by weight) and can be coated onto reinforcing fiber to produce prepegs with excellent tack and drape at 12-15% residual solvent (approximately 4-6% water from thermal imidization reaction). The processing of these types of prepegs significantly overcomes solvent removal problems and allows excellent fiber wet out. In addition, the physical characteristics of the polyimide precursor salt-like solutions permits processing into high-performance materials through the use of standard prepregging and composite fabrication equipment. The resultant composites are of high quality.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mahoney, Christine M.; Kelly, Ryan T.; Alexander, M. L.
Key elements regarding the use of non-radioactive ionization sources will be presented as related to explosives detection by mass spectrometry and ion mobility spectrometry. Various non-radioactive ionization sources will be discussed along with associated ionization mechanisms pertaining to specific sample types.
NASA Astrophysics Data System (ADS)
Ahmed, Nasar; Abdullah, M.; Ahmed, Rizwan; Piracha, N. K.; Aslam Baig, M.
2018-01-01
We present a quantitative analysis of a brass alloy using laser induced breakdown spectroscopy, energy dispersive x-ray spectroscopy (EDX) and laser ablation time-of-flight mass spectrometry (LA-TOF-MS). The emission lines of copper (Cu I) and zinc (Zn I), and the constituent elements of the brass alloy were used to calculate the plasma parameters. The plasma temperature was calculated from the Boltzmann plot as (10 000 ± 1000) K and the electron number density was determined as (2.0 ± 0.5) × 1017 cm-3 from the Stark-broadened Cu I line as well as using the Saha-Boltzmann equation. The elemental composition was deduced using these techniques: the Boltzmann plot method (70% Cu and 30% Zn), internal reference self-absorption correction (63.36% Cu and 36.64% Zn), EDX (61.75% Cu and 38.25% Zn), and LA-TOF (62% Cu and 38% Zn), whereas, the certified composition is (62% Cu and 38% Zn). It was observed that the internal reference self-absorption correction method yields analytical results comparable to that of EDX and LA-TOF-MS.
Single-Shot Laser Ablation Split-Stream (SS-LASS) Analysis Depth Profiling
NASA Astrophysics Data System (ADS)
Kylander-Clark, A. R.; Stearns, M. A.; Viete, D. R.; Cottle, J. M.; Hacker, B. R.
2014-12-01
Laser ablation depth profiling of geochronometers—such as zircon, monazite, titanite and rutile—has become popular in recent years as a tool to both determine date vs. depth or trace-element (TE) composition vs. depth; the former allows the dating of thin rims and, potentially, inversion of Pb-loss profiles for thermal histories, whereas the latter can yield insight into changes in PTX or mineral parageneses and inversion of trace-element profiles for thermal histories. In this study, we combine both techniques, enabling simultaneous acquisition of U-Th/Pb isotopic ratios and trace-element compositions, by joining a 193 nm excimer laser to a multi-collector ICP-MS and single-collector ICP-MS. The simultaneous acquisition allows direct shot-by-shot linkage between time and petrology, expanding our ability to understand the evolution of complex geologic systems. We construct each depth profile by capturing the analyte with a succession of individual laser pulses (each ~100 nm deep) . This has two main advantages over a typical time-dependent analysis of a multi-shot routine composed of tens to hundreds of shots and a several μm deep hole. 1) The reference material is analyzed between each shot for a more-accurate standardization of each aliquot of ablated material. 2) There is no mixing of material ablated from successive laser pulses during transmission to the ICP. The method is limited by count rate, which depends on spot size, excavation rate, instrument sensitivity, etc., and, for single-collector ICP, the switching time, which limits the number of elements that can be analyzed and their total counts. We explore the latter theoretically and experimentally to provide insight on both the ideal number of elements to measure and the dwell time in any given sample. Examples of the utility of SS-LASS include the comparison of apparent Pb loss to diffusion profiles of trace elements in rims of metamorphic rutile and titanite, as well as the determination of the timing and petrologic conditions of thin zircon rims in metamorphic rocks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blanchard, Miran; Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota; Shim, Kevin G.
Purpose: The oligometastatic state is an intermediate state between a malignancy that can be completely eradicated with conventional modalities and one in which a palliative approach is undertaken. Clinically, high rates of local tumor control are possible with stereotactic ablative radiation therapy (SABR), using precisely targeted, high-dose, low-fraction radiation therapy. However, in oligometastatic melanoma, virtually all patients develop progression systemically at sites not initially treated with ablative radiation therapy that cannot be managed with conventional chemotherapy and immunotherapy. We have demonstrated in mice that intravenous administration of vesicular stomatitis virus (VSV) expressing defined tumor-associated antigens (TAAs) generates systemic immune responsesmore » capable of clearing established tumors. Therefore, in the present preclinical study, we tested whether the combination of systemic VSV-mediated antigen delivery and SABR would be effective against oligometastatic disease. Methods and Materials: We generated a model of oligometastatic melanoma in C57BL/6 immunocompetent mice and then used a combination of SABR and systemically administered VSV-TAA viral immunotherapy to treat both local and systemic disease. Results: Our data showed that SABR generates excellent control or cure of local, clinically detectable, and accessible tumor through direct cell ablation. Also, the immunotherapeutic activity of systemically administered VSV-TAA generated T-cell responses that cleared subclinical metastatic tumors. We also showed that SABR induced weak T-cell-mediated tumor responses, which, particularly if boosted by VSV-TAA, might contribute to control of local and systemic disease. In addition, VSV-TAA therapy alone had significant effects on control of both local and metastatic tumors. Conclusions: We have shown in the present preliminary murine study using a single tumor model that this approach represents an effective, complementary combination therapy model that addresses the need for both systemic and local control in oligometastatic melanoma.« less
NASA Technical Reports Server (NTRS)
Arnold, Steven M.; Murthy, Pappu L.; Bednarcyk, Brett A.; Lawson, John W.; Monk, Joshua D.; Bauschlicher, Charles W., Jr.
2016-01-01
Next generation ablative thermal protection systems are expected to consist of 3D woven composite architectures. It is well known that composites can be tailored to achieve desired mechanical and thermal properties in various directions and thus can be made fit-for-purpose if the proper combination of constituent materials and microstructures can be realized. In the present work, the first, multiscale, atomistically-informed, computational analysis of mechanical and thermal properties of a present day - Carbon/Phenolic composite Thermal Protection System (TPS) material is conducted. Model results are compared to measured in-plane and out-of-plane mechanical and thermal properties to validate the computational approach. Results indicate that given sufficient microstructural fidelity, along with lowerscale, constituent properties derived from molecular dynamics simulations, accurate composite level (effective) thermo-elastic properties can be obtained. This suggests that next generation TPS properties can be accurately estimated via atomistically informed multiscale analysis.
Yan, Xiaoting; Tong, Zongrui; Chen, Yu; Mo, Yanghe; Feng, Huaiyu; Li, Peng; Qu, Xiaosai; Jin, Shaohua
2017-01-01
Carboxymethyl chitosan (CMCS) microparticles are a potential candidate for hemostatic wound dressing. However, its low swelling property limits its hemostatic performance. Poly(γ-glutamic acid) (PGA) is a natural polymer with excellent hydrophilicity. In the current study, a novel CMCS/PGA composite microparticles with a dual-network structure was prepared by the emulsification/internal gelation method. The structure and thermal stability of the composite were determined by Fourier transform infrared spectroscopy (FTIR), X-ray powder diffraction (XRD), scanning electron microscope (SEM), X-ray photoelectron spectroscopy (XPS), and thermogravimetric analysis (TGA). The effects of preparation conditions on the swelling behavior of the composite were investigated. The results indicate that the swelling property of CMCS/PGA composite microparticles is pH sensitive. Levofloxacin (LFX) was immobilized in the composite microparticles as a model drug to evaluate the drug delivery performance of the composite. The release kinetics of LFX from the composite microparticles with different structures was determined. The results suggest that the CMCS/PGA composite microparticles are an excellent candidate carrier for drug delivery. PMID:28452963
NASA Astrophysics Data System (ADS)
Peláez, R. J.; Afonso, C. N.; Bator, M.; Lippert, T.
2013-06-01
The aim of this work is to demonstrate that single-photon photoionization processes make a significant difference in the expansion and temperature of the plasma produced by laser ablation of ceramic Al2O3 in vacuum as well as to show their consequences in the kinetic energy distribution of the species that eventually will impact on the film properties produced by pulsed laser deposition. This work compares results obtained by mass spectrometry and optical spectroscopy on the composition and features of the plasma produced by laser ablation at 193 nm and 248 nm, i.e., photon energies that are, respectively, above and below the ionization potential of Al, and for fluences between threshold for visible plasma and up to ≈2 times higher. The results show that the ionic composition and excitation of the plasma as well as the ion kinetic energies are much higher at 193 nm than at 248 nm and, in the latter case, the population of excited ions is even negligible. The comparison of Maxwell-Boltzmann temperature, electron temperatures, and densities of the plasmas produced with the two laser wavelengths suggests that the expansion of the plasma produced at 248 nm is dominated by a single population. Instead, the one produced at 193 nm is consistent with the existence of two populations of cold and hot species, the latter associated to Al+ ions that travel at the forefront and produced by single photon ionization as well as Al neutrals and double ionized ions produced by electron-ion impact. The results also show that the most energetic Al neutrals in the plasma produced at the two studied wavelengths are in the ground state.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Casner, A.; Masse, L.; Delorme, B.
Understanding and mitigating hydrodynamic instabilities and the fuel mix are the key elements for achieving ignition in Inertial Confinement Fusion. Cryogenic indirect-drive implosions on the National Ignition Facility have evidenced that the ablative Rayleigh-Taylor Instability (RTI) is a driver of the hot spot mix. This motivates the switch to a more flexible higher adiabat implosion design [O. A. Hurricane et al., Phys. Plasmas 21, 056313 (2014)]. The shell instability is also the main candidate for performance degradation in low-adiabat direct drive cryogenic implosions [Goncharov et al., Phys. Plasmas 21, 056315 (2014)]. This paper reviews recent results acquired in planar experimentsmore » performed on the OMEGA laser facility and devoted to the modeling and mitigation of hydrodynamic instabilities at the ablation front. In application to the indirect-drive scheme, we describe results obtained with a specific ablator composition such as the laminated ablator or a graded-dopant emulator. In application to the direct drive scheme, we discuss experiments devoted to the study of laser imprinted perturbations with special phase plates. The simulations of the Richtmyer-Meshkov phase reversal during the shock transit phase are challenging, and of crucial interest because this phase sets the seed of the RTI growth. Recent works were dedicated to increasing the accuracy of measurements of the phase inversion. We conclude by presenting a novel imprint mitigation mechanism based on the use of underdense foams. Lastly, the foams induce laser smoothing by parametric instabilities thus reducing the laser imprint on the CH foil.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Casner, A., E-mail: alexis.casner@cea.fr; Masse, L.; Huser, G.
Understanding and mitigating hydrodynamic instabilities and the fuel mix are the key elements for achieving ignition in Inertial Confinement Fusion. Cryogenic indirect-drive implosions on the National Ignition Facility have evidenced that the ablative Rayleigh-Taylor Instability (RTI) is a driver of the hot spot mix. This motivates the switch to a more flexible higher adiabat implosion design [O. A. Hurricane et al., Phys. Plasmas 21, 056313 (2014)]. The shell instability is also the main candidate for performance degradation in low-adiabat direct drive cryogenic implosions [Goncharov et al., Phys. Plasmas 21, 056315 (2014)]. This paper reviews recent results acquired in planar experimentsmore » performed on the OMEGA laser facility and devoted to the modeling and mitigation of hydrodynamic instabilities at the ablation front. In application to the indirect-drive scheme, we describe results obtained with a specific ablator composition such as the laminated ablator or a graded-dopant emulator. In application to the direct drive scheme, we discuss experiments devoted to the study of laser imprinted perturbations with special phase plates. The simulations of the Richtmyer-Meshkov phase reversal during the shock transit phase are challenging, and of crucial interest because this phase sets the seed of the RTI growth. Recent works were dedicated to increasing the accuracy of measurements of the phase inversion. We conclude by presenting a novel imprint mitigation mechanism based on the use of underdense foams. The foams induce laser smoothing by parametric instabilities thus reducing the laser imprint on the CH foil.« less
NASA Astrophysics Data System (ADS)
Darling, J. R.; Storey, C. D.; Hawkesworth, C. J.; Lightfoot, P. C.
2012-12-01
Laser-ablation (LA) multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS) is ideally suited to in situ determination of isotope ratios in sulphide minerals. Using samples of magmatic sulphide ore from the Sudbury impact structure, we test LA-MC-ICPMS analytical protocols that aim to meet a range of analytical challenges in the analysis of Pb isotopes. These include: potential matrix sensitive isotopic fractionation; interferences on Pb isotopes; low melting points of many sulphide minerals; the availability of standards. Magmatic sulphides of wide ranging mineralogy (pyrrhotite, pentlandite, chalcopyrite, pyrite and sphalerite) were analysed for Pb isotopic composition, using the silicate glass NIST SRM 610 as an external standard to correct for instrumental mass-fractionation. Despite matrix sensitive melting and re-deposition around ablation pits, several lines of evidence indicate that all analyses are accurate, within typical analytical uncertainties of 0.003-2% (2σ), and that the defined approach is insensitive to compositional diversity in sample matrix: (a) laser ablation and dissolution based measurements of sulphide powders are in agreement; (b) analyses from each sample define isochron ages within uncertainty of the known crystallization age (1850 Ma); (c) the results of sulphide measurements by laser ablation are consistent with age-corrected feldspar analyses from the same samples. The results have important implications for ore formation in Sudbury. The Pb isotope data regressions are consistent with age corrected feldspar analyses from each respective sample, which together with time integrated Th/U ratios that match whole rock values (3.1, 4.0 and 6.1 for the Worthington, Copper Cliff and Parkin Offset Dykes, respectively) indicate chemical equilibrium between the silicate and sulphide systems during ore formation. The sulphides within each respective sample have indistinguishable model initial Pb isotope ratios (207Pb/204Pbm), irrespective of mineralogy or texture, indicating a common origin for ores within each of three different Offset Dykes. Furthermore, variations between Offset Dykes (e.g., 207Pb/204Pbm = 15.514 ± 0.012, 15.399 ± 0.009 and 15.275 ± 0.003) show that the ores have differing crustal sources on previously unrecognized scales. Mass balance considerations, particularly for MgO, Ni and Cu, indicate that the spatial distribution of mafic target rocks played a significant role in controlling the mineralization potential in different parts of the melt sheet.
A model of early formation of uranium molecular oxides in laser-ablated plasmas
NASA Astrophysics Data System (ADS)
Finko, Mikhail; Curreli, Davide; Azer, Magdi; Weisz, David; Crowhurst, Jonathan; Rose, Timothy; Koroglu, Batikan; Radousky, Harry; Zaug, Joseph; Armstrong, Mike
2017-10-01
An important problem within the field of nuclear forensics is fractionation: the formation of post-detonation nuclear debris whose composition does not reflect that of the source weapon. We are investigating uranium fractionation in rapidly cooling plasma using a combined experimental and modeling approach. In particular, we use laser ablation of uranium metal samples to produce a low-temperature plasma with physical conditions similar to a condensing nuclear fireball. Here we present a first plasma-chemistry model of uranium molecular species formation during the early stage of laser ablated plasma evolution in atmospheric oxygen. The system is simulated using a global kinetic model with rate coefficients calculated according to literature data and the application of reaction rate theory. The model allows for a detailed analysis of the evolution of key uranium molecular species and represents the first step in producing a uranium fireball model that is kinetically validated against spatially and temporally resolved spectroscopy measurements. This project was sponsored by the DoD, Defense Threat Reduction Agency, Grant HDTRA1-16- 1-0020. This work was performed in part under the auspices of the U.S. DoE by Lawrence Livermore National Laboratory under Contract DE-AC52- 07NA27344.
LaHaye, Nicole L.; Kurian, Jose; Diwakar, Prasoon K.; ...
2015-08-19
An accurate and routinely available method for stoichiometric analysis of thin films is a desideratum of modern materials science where a material’s properties depend sensitively on elemental composition. We thoroughly investigated femtosecond laser ablation-inductively coupled plasma-mass spectrometry (fs-LA-ICP-MS) as an analytical technique for determination of the stoichiometry of thin films down to the nanometer scale. The use of femtosecond laser ablation allows for precise removal of material with high spatial and depth resolution that can be coupled to an ICP-MS to obtain elemental and isotopic information. We used molecular beam epitaxy-grown thin films of LaPd (x)Sb 2 and T´-La 2CuOmore » 4 to demonstrate the capacity of fs-LA-ICP-MS for stoichiometric analysis and the spatial and depth resolution of the technique. Here we demonstrate that the stoichiometric information of thin films with a thickness of ~10 nm or lower can be determined. Furthermore, our results indicate that fs-LA-ICP-MS provides precise information on the thin film-substrate interface and is able to detect the interdiffusion of cations.« less
NASA Astrophysics Data System (ADS)
Brown, Staci R.; Akpovo, Charlemagne A.; Martinez, Jorge; Ford, Alan; Herbert, Kenley; Johnson, Lewis
2014-03-01
Laser Induced Breakdown Spectroscopy (LIBS) is a spectroscopic technique that is used for the qualitative and quantitative analysis of materials in the liquid, solid, or gas phase. LIBS can also be used for the detection of isotopic shifts in atomic and diatomic species via Laser-Ablation Molecular Isotopic Spectroscopy (LAMIS). However, any additional elements that are entrained into the plasma other than the element of interest, can affect the extent of ablation and quality of spectra and hence, potentially obscure or aid in the relative abundance assessment for a given element. To address the importance of matrix effects, the isotopic analysis of boron obtained from boron oxide (BO) emission originating from different boron-containing compounds, such as boron nitride (BN), boric acid (H3BO3) , and borax (Na2B4O710H2O), via LIBS has been performed here. Each of these materials has different physical properties and elemental composition in order to illustrate possible challenges for the LAMIS method. A calibration-free model similar to that for the original LAMIS work is used to determine properties of the plasma as the matrix is changed. DTRA
Lasers in clinical urology: state of the art and new horizons.
Marks, Andrew J; Teichman, Joel M H
2007-06-01
We present an overview of current and emerging lasers for Urology. We begin with an overview of the Holmium:YAG laser. The Ho:YAG laser is the gold standard lithotripsy modality for endoscopic lithotripsy, and compares favorably to standard electrocautery transurethral resection of the prostate for benign prostatic hyperplasia (BPH). Available laser technologies currently being studied include the frequency doubled double-pulse Nd:Yag (FREDDY) and high-powered potassium-titanyl-phosphate (KTP) lasers. The FREDDY laser presents an affordable and safe option for intracorporeal lithotripsy, but it does not fragment all stone compositions, and does not have soft tissue applications. The high power KTP laser shows promise in the ablative treatment of BPH. Initial experiments with the Erbium:YAG laser show it has improved efficiency of lithotripsy and more precise ablative and incisional properties compared to Ho:YAG, but the lack of adequate optical fibers limits its use in Urology. Thulium:YAG fiber lasers have also demonstrated tissue ablative and incision properties comparable to Ho:YAG. Lastly, compact size, portability, and low maintenance schedules of fiber lasers may allow them to shape the way lasers are used by urologists in the future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Liu; Liu, Jinxu, E-mail: liujinxu@bit.edu.cn; Zhang, Xinbo
2015-11-15
Energetic structural material is a kind of materials that are inert under normal conditions but could produce exothermic chemical reaction when subjected to impact. This report shows a kind of energetic structural material of tungsten (W)-polytetrafluoroethylene (PTFE)-aluminum (Al) with density of 4.12 g/cm{sup 3}, excellent ductility and dynamic compressive strength of 96 MPa. Moreover, 50W-35PTFE-15Al (wt%) can exhibit a high reaction energy value of more than 2 times of TNT per unit mass and 5 times of TNT per unit volume, respectively, but with excellent insensitivity compared with traditional explosives. Under thermal conditions, the W-PTFE-Al composite can keep stable atmore » 773 K. Under impact loading, when the strain rate up to ∼4820 s{sup −1} coupled with the absorbed energy per unit volume of 120 J/cm{sup 3}, deflagration occurs and combustion lasts for 500 μs. During impact compressive deformation, the PTFE matrix is elongated into nano-fibers, thus significantly increases the reaction activity of W-PTFE-Al composites. The nano-fiber structure is necessary for the reaction of W-PTFE-Al composites. The formation of PTFE nano-fibers must undergo severe plastic deformation, and therefore the W-PTFE-Al composites exhibit excellent insensitivity and safety. Furthermore, the reaction mechanisms of W-PTFE-Al composites in argon and in air are revealed.« less
One-step synthesis of multi-emission carbon nanodots for ratiometric temperature sensing
NASA Astrophysics Data System (ADS)
Nguyen, Vanthan; Yan, Lihe; Xu, Huanhuan; Yue, Mengmeng
2018-01-01
Measuring temperature with greater precision at localized small length scales or in a nonperturbative manner is a necessity in widespread applications, such as integrated photonic devices, micro/nano electronics, biology, and medical diagnostics. To this context, use of nanoscale fluorescent temperature probes is regarded as the most promising method for temperature sensing because they are noninvasive, accurate, and enable remote micro/nanoscale imaging. Here, we propose a novel ratiometric fluorescent sensor for nanothermometry using carbon nanodots (C-dots). The C-dots were synthesized by one-step method using femtosecond laser ablation and exhibit unique multi-emission property due to emissions from abundant functional groups on its surface. The as-prepared C-dots demonstrate excellent ratiometric temperature sensing under single wavelength excitation that achieves high temperature sensitivity with a 1.48% change per °C ratiometric response over wide-ranging temperature (5-85 °C) in aqueous buffer. The ratiometric sensor shows excellent reversibility and stability, holding great promise for the accurate measurement of temperature in many practical applications.
The origin of Cu/Au ratios in porphyry-type ore deposits.
Halter, Werner E; Pettke, Thomas; Heinrich, Christoph A
2002-06-07
Microanalysis of major and trace elements in sulfide and silicate melt inclusions by laser-ablation inductively coupled plasma mass spectrometry indicates a direct link between a magmatic sulfide liquid and the composition of porphyry-type ore deposits. Copper (Cu), gold (Au), and iron (Fe) are first concentrated in a sulfide melt during magmatic evolution and then released to an ore-forming hydrothermal fluid exsolved late in the history of a magma chamber. The composition of sulfide liquids depends on the initial composition and source of the magma, but it also changes during the evolution of the magma in the crust. Magmatic sulfide melts may exert the dominant direct control on the economic metal ratios of porphyry-type ore deposits.
NASA Astrophysics Data System (ADS)
Ma, Wen; Liu, Fushun
Voids are inevitable in the fabrication of fiber reinforced composites and have a detrimental impact on mechanical properties of composites. Different void contents were acquired by applying different vacuum bag pressures. Ultrasonic inspection and ablation density method were adopted to measure the ultrasonic characteristic parameters and average porosity, the characterization of voids' distribution, shape and size were carried out through metallographic analysis. Effects of void content on the tensile, flexural and interlaminar shear properties and the ultrasonic characteristic parameters were discussed. The results showed that, as vacuum bag pressure went from -50kPa to -98kPa, the voids content decreased from 4.36 to 0.34, the ultrasonic attenuation coefficient decreased, but the mechanical strengths all increased.
Optical Spectroscopy of New Materials
NASA Technical Reports Server (NTRS)
White, Susan M.; Arnold, James O. (Technical Monitor)
1993-01-01
Composites are currently used for a rapidly expanding number of applications including aircraft structures, rocket nozzles, thermal protection of spacecraft, high performance ablative surfaces, sports equipment including skis, tennis rackets and bicycles, lightweight automobile components, cutting tools, and optical-grade mirrors. Composites are formed from two or more insoluble materials to produce a material with superior properties to either component. Composites range from dispersion-hardened alloys to advanced fiber-reinforced composites. UV/VIS and FTIR spectroscopy currently is used to evaluate the bonding between the matrix and the fibers, monitor the curing process of a polymer, measure surface contamination, characterize the interphase material, monitor anion transport in polymer phases, characterize the void formation (voids must be minimized because, like cracks in a bulk material, they lead to failure), characterize the surface of the fiber component, and measure the overall optical properties for energy balances.
Spallation modeling in the Charring Material Thermal Response and Ablation (CMA) computer program
NASA Astrophysics Data System (ADS)
Sullivan, J. M.; Kobayashi, W. S.
1987-06-01
It has been observed during tests of certain laminated composite materials exposed to relatively high continuous wave laser irradiation, that the heated surface will spall. To model this phenomenon, the Charring Material Thermal Response and Ablation code has been updated. In addition to temperature response, in-depth decomposition, and surface recession, thermal and mechanical stresses are calculated. Spall is modeled as a discrete mass removal event occurring when the stresses exceed the ultimate strength of the char through a critical depth. Comparisons are made with test data for a carbon phenolic cylinder exposed to a shock tube environment and for a flat plate Kevlar epoxy test specimen exposed to high intensity laser irradiation. Good agreement is shown; however, the results indicate a requirement for more comprehensive elevated-temperature material properties for further validation.
Laser Ablation Mass Spectrometer (LAMS) as a Standoff Analyzer in Space Missions for Airless Bodies
NASA Technical Reports Server (NTRS)
Li, X.; Brinckerhoff, W. B.; Managadze, G. G.; Pugel, D. E.; Corrigan, C. M.; Doty, J. H.
2012-01-01
A laser ablation mass spectrometer (LAMS) based on a time-of-flight (TOF) analyzer with adjustable drift length is proposed as a standoff elemental composition sensor for space missions to airless bodies. It is found that the use of a retarding potential analyzer in combination with a two-stage reflectron enables LAMS to be operated at variable drift length. For field-free drift lengths between 33 cm to 100 cm, at least unit mass resolution can be maintained solely by adjustment of internal voltages, and without resorting to drastic reductions in sensitivity. Therefore, LAMS should be able to be mounted on a robotic arm and analyze samples at standoff distances of up to several tens of cm, permitting high operational flexibility and wide area coverage of heterogeneous regolith on airless bodies.
Wang, Haohao; Odawara, Osamu; Wada, Hiroyuki
2016-01-01
A YVO4:Eu3+ colloid with an interesting nanostructure was formed by pulsed laser ablation in deionized water without any additives or surfactants. Analyses of particle morphology, composition and optical properties were accomplished by SEM, TEM, EDS PL and UV-vis. Ovoid-like particles formed by the agglomeration of numerous nanocrystals were observed by SEM and TEM, while EDS with area-mode analysis revealed that the content of dopant ion was well retained within the nanoparticles. In addition, the formation mechanism is deduced and discussed for the first time in this research. The findings of this study could provide new insights into the understanding of laser-induced oxide materials and offer an opportunity for other research groups to pursue red emitting nanophosphors with outstandingly purity. PMID:26842419
Inferring the Composition of Super-Jupiter Mass Companions of Pulsars with Radio Line Spectroscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ray, Alak; Loeb, Abraham, E-mail: akr@tifr.res.in, E-mail: aloeb@cfa.harvard.edu
We propose using radio line spectroscopy to detect molecular absorption lines (such as OH at 1.6–1.7 GHz) before and after the total eclipse of black widow and other short orbital period binary pulsars with low-mass companions. The companion in such a binary may be ablated away by energetic particles and high-energy radiation produced by the pulsar wind. The observations will probe the eclipsing wind being ablated by the pulsar and constrain the nature of the companion and its surroundings. Maser emission from the interstellar medium stimulated by a pulsar beam might also be detected from the intrabinary medium. The shortmore » temporal resolution allowed by the millisecond pulsars can probe this medium with the high angular resolution of the pulsar beam.« less
NASA Technical Reports Server (NTRS)
Hergenrother, Paul M. (Inventor); Bryant, Robert G. (Inventor); Jensen, Brian J. (Inventor); Havens, Stephen J. (Inventor)
1997-01-01
Four phenylethynyl amine compounds--3 and 4-aminophenoxy-4'-phenylethynylbenzophenone, and 3 and 4-amino-4'-phenylethynylbenzophenone--were readily prepared and were used to endcap imide oligomers. Phenylethynyl-terminated amide acid oligomers and phenylethynyl-terminated imide oligomers with various molecular weights and compositions were prepared and characterized. These oligomers were cured at 300.degree. C. to 400.degree. C. to provide crosslinked polyimides with excellent solvent resistance, high strength and modulus and good high temperature properties. Adhesive panels, composites, films and moldings from these phenylethynyl terminated imide oligomers gave excellent mechanical performance.
Phenylethynyl terminated imide oligomers
NASA Technical Reports Server (NTRS)
Hergenrother, Paul M. (Inventor); Bryant, Robert G. (Inventor); Jensen, Brian J. (Inventor); Havens, Stephen J. (Inventor)
1994-01-01
Four phenylethynyl amine compounds - 3 and 4-aminophenoxy-4'-phenylethynylbenzophenone, and 3 and 4-amino-4'-phenylethynylbenzophenone - were readily prepared and were used to endcap imide oligomers. Phenylethynyl-terminated amide acid oligomers and phenylethynyl-terminated imide oligomers with various molecular weights and compositions were prepared and characterized. These oligomers were cured at 300 to 400 C to provide crosslinked polyimides with excellent solvent resistance, high strength and modulus, and good high temperature properties. Adhesive panels, composites, films, and moldings from these phenylethynyl terminated imide oligomers gave excellent mechanical performance.
Phenylethynyl terminated imide oligomers
NASA Technical Reports Server (NTRS)
Hergenrother, Paul M. (Inventor); Bryant, Robert G. (Inventor); Jensen, Brian J. (Inventor); Havens, Stephen J. (Inventor)
1995-01-01
Four phenylethynyl amine compounds - 3 and 4-aminophenoxy-4'-phenylethynylbenzophenone, and 3 and 4-amino-4'-phenylethynylbenzophenone - were readily prepared and were used to endcap imide oligomers. Phenylethynyl-terminated amide acid oligomers and phenylethynyl-terminated imide oligomers with various molecular weights and compositions were prepared and characterized. These oligomers were cured at 300 to 400 C to provide crosslinked polyimides with excellent solvent resistance, high strength and modulus, and good high temperature properties. Adhesive panels, composites, films, and moldings from these phenylethynyl terminated imide oligomers gave excellent mechanical performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cui, Zhongping; Qi, Ji; Xu, Xinxin, E-mail: xuxx@mail.neu.edu.cn
2013-09-15
To enhance photocatalytic property of coordination polymer in visible light region, polyaniline (PANI) loaded coordination polymer photocatalyst was synthesized through in-situ chemical oxidation of aniline on the surface of coordination polymer. The photocatalytic activity of PANI loaded coordination polymer composite material for degradation of Rhodamine B (RhB) was investigated. Compared with pure coordination polymer photocatalyst, which can decompose RhB merely under UV light irradiation, PANI loaded coordination polymer photocatalyst displays more excellent photocatalytic activity in visible light region. Furthermore, PANI loaded coordination polymer photocatalyst exhibits outstanding stability during the degradation of RhB. - Graphical abstract: PANI loaded coordination polymer compositemore » material, which displays excellent photocatalytic activity under visible light was firstly synthesized through in-situ chemical oxidation of aniline on surface of coordination polymer. Display Omitted - Highlights: • This PANI loaded coordination polymer composite material represents the first conductive polymer loaded coordination polymer composite material. • PANI/coordination polymer composite material displays more excellent photocatalytic activity for the degradation of MO in visible light region. • The “combination” of coordination polymer and PANI will enable us to design high-activity, high-stability and visible light driven photocatalyst in the future.« less
Nitrogen-doped carbon coated MnO nanopeapods as superior anode materials for lithium ion batteries
NASA Astrophysics Data System (ADS)
Ding, Yu; Chen, Lihui; Pan, Pei; Du, Jun; Fu, Zhengbing; Qin, Caiqin; Wang, Feng
2017-11-01
High performance nitrogen-doped carbon (NC) materials decorated with MnO hybrid (MnO@NC) composites with a nanopeapod appearance were synthesized by with a simple hydrothermal method and insuit-polymeric route. As an anode material for lithium ion batteries (LIBs), the nanopeapod structure of MnO@NC composites with internal void spaces exhibits good rate capability, high conductivity and excellent cycling stability. After 200 cycles, the nanopeapod composites yield a specific capacity of 775.4 mAh g-1 at 100 mA g-1 and a high-rate capacity of 559.7 mAh g-1 at 1000 mA g-1. The proposed synthesis of nanopeapod structure composites with an internal room is an efficient design with excellent electrode materials for rechargeable LIBs.
NASA Astrophysics Data System (ADS)
Wang, Haiyan; Li, Mingjie; Li, Xueai
2016-12-01
The carbonyl iron particles were dispersed in a polychloroprene rubber (CR) matrix under a magnetic field for a practical application as microwave absorption composites film. In comparison with the carbonyl iron particles (CIP)/CR composites film prepared by general route, such films made with external magnetic field exhibit excellent microwave absorption properties, strongly depending on the increment of anisotropy and rearrangement of magnetic particles. The film made under external magnetic field with a thickness of only 0.54 mm shows least reflection loss of -15.98 dB and the reflection loss value less than -10.0 dB over the frequency range of 11.4˜14.8 GHz. The results indicated the composite film made under external magnetic field have excellent microwave absorption properties, which suggest that the composites thin film could be used as a thinner and lighter microwave absorber.
Magnetic resonance-guided focused ultrasound surgery for treatment of painful osseous metastases
NASA Astrophysics Data System (ADS)
Hurwitz, Mark; Machtinger, Ronit; Fennessy, Fiona
2011-03-01
Magnetic resonance guided focused ultrasound surgery (MRgFUS) is an emerging technology that can non-invasively heat and ablate targeted tissue utilizing ultrasound energy. Use of MR imaging for treatment guidance provides several key advantages over more widely used ultrasound guidance for focused ultrasound ablation. MR allows for precise targeting, detailed beam path visualization, real time non-invasive temperature measurement, and treatment feedback to ensure therapeutic goals are achieved. In the realm of oncology, management of painful bone metastases is a common and daunting clinical problem. The Insightec ExAblate System has been shown in phase I/II trials for treatment of bone metastases to have an excellent safety profile and high rates of pain response. An international multi-center phase III trial for patients with painful bone metastases or multiple myeloma who are not candidates for radiation therapy is currently open. Patients are randomized 3:1 to MRgFUS or sham treatment with crossover to study treatment allowed for sham failures. The primary study endpoint is assessment of pain control over 3 months following treatment. In addition safety, quality of life, cost effectiveness analysis, and patient perceived clinical benefit are also being assessed. Details of the MRgFUS system, technical and clinical therapeutic parameters, use of real time non-invasive MR thermometry, and examples of patient treatments with use of MRgFUS to treat bone metastases will be discussed. New directions in use of MRgFUS including an update on development of a new mobile applicator and integration of MRgFUS in multimodality oncologic care will also be presented.
Analysis and studies on the threats to the composite material from laser
NASA Astrophysics Data System (ADS)
Xu, Wei; Yao, Weixing; Wang, Liwei; Wang, Guoliang; Xie, Fang
2015-10-01
It is always an attracting research field for the interaction between laser and matters. The interaction between laser and matters is used not only in the natural science, but also in practical application, for example, laser machine, laser weapon, laser ablations and so on. In this paper, we will give the model for the damage effect of the composite materials caused by the superpower laser weapons. Mechanism of the laser damage on the composite materials have been researched and modeled by the numerical analysis methods. Through the designed model, we analyzed the temperature and the stress fields of the composite material after the superpower lasers attacks with different power densities. By analyzing these modeling results, we achieved some conclusions on the threats to the composite materials from the superpower lasers. From the results, we have obtained the Irradiated threshold from the Laser. This paper will provide the theoretical foundations for the anti-laser design of the composite materials.
Tang, Chunjuan; Wei, Xiujuan; Cai, Xinyin; An, Qinyou; Hu, Ping; Sheng, Jinzhi; Zhu, Jiexin; Chou, Shulei; Wu, Liming; Mai, Liqiang
2018-06-13
Sodium-ion batteries (SIBs) are considered as one of the most favorable alternative devices for sustainable development of modern society. However, it is still a big challenge to search for proper anode materials which have excellent cycling and rate performance. Here, zinc selenide microsphere and multiwalled carbon nanotube (ZnSe/MWCNT) composites are prepared via hydrothermal reaction and following grinding process. The performance of ZnSe/MWCNT composites as a SIB anode is studied for the first time. As a result, ZnSe/MWCNTs exhibit excellent rate capacity and superior cycling life. The capacity retains as high as 382 mA h g -1 after 180 cycles even at a current density of 0.5 A g -1 . The initial Coulombic efficiency of ZnSe/MWCNTs can reach 88% and nearby 100% in the following cycles. The superior electrochemical properties are attributed to continuous electron transport pathway, improved electrical conductivity, and excellent stress relaxation.
A Mass Spectrometry Study of Isotope Separation in the Laser Plume
NASA Astrophysics Data System (ADS)
Suen, Timothy Wu
Accurate quantification of isotope ratios is critical for both preventing the development of illicit weapons programs in nuclear safeguards and identifying the source of smuggled material in nuclear forensics. While isotope analysis has traditionally been performed by mass spectrometry, the need for in situ measurements has prompted the development of optical techniques, such as laser-induced breakdown spectroscopy (LIBS) and laser ablation molecular isotopic spectrometry (LAMIS). These optical measurements rely on laser ablation for direct solid sampling, but several past studies have suggested that the distribution of isotopes in the ablation plume is not uniform. This study seeks to characterize isotope separation in the laser plume through the use of orthogonal-acceleration time-of-flight mass spectrometry. A silver foil was ablated with a Nd:YAG at 355 nm at an energy of 50 muJ with a spot size of 71 mum, for a fluence of 1.3 J/cm2 and an irradiance of 250 MW/cm2. Flat-plate repellers were used to sample the plume, and a temporal profile of the ions was obtained by varying the time delay on the high-voltage pulse. A spatial profile along the axis of the plume was generated by changing the position of the sample, which yielded snapshots of the isotopic composition with time. In addition, the reflectron time-of-flight system was used as an energy filter in conjunction with the repellers to sample slices of the laser plasma orthogonal to the plume axis. Mass spectrometry of the plume revealed a fast ion distribution and a slow ion distribution. Measurements taken across the entire plume showed the fast 109Ag ions slightly ahead in both space and time, causing the 107Ag fraction to drop to 0.34 at 3 mus, 4 mm from the sample surface. Although measurements centered on the near side of the plume did not show isotope separation, the slow ions on the far side of the plume included much more 109Ag than 107Ag. In addition to examining the isotope content of the ablation plume, this study has developed a mass spectrometry characterization technique that may be useful for investigating chemical reactions during laser ablation.
NASA Astrophysics Data System (ADS)
Li, Jing; Xie, Huaqing; Li, Yang; Liu, Jie; Li, Zhuxin
Graphene nanosheets/polyaniline nanofibers (GNS/PANI) composites are synthesized via in situ polymerization of aniline monomer in HClO 4 solution. The PANI nanofibers homogeneously coating on the surface of GNS greatly improve the charge transfer reaction. The GNS/PANI composites exhibit better electrochemical performances than the pure individual components. A remarkable specific capacitance of 1130 F g -1 (based on GNS/PANI composites) is obtained at a scan rate of 5 mV s -1 in 1 M H 2SO 4 solution compared to 402 F g -1 for pure PANI and 270 F g -1 for GNS. The excellent performance is not only due to the GNS which can provide good electrical conductivity and high specific surface area, but also associate with a good redox activity of ordered PANI nanofibers. Moreover, the GNS/PANI composites present excellent long cycle life with 87% specific capacitance retained after 1000 charge/discharge processes. The resulting composites are promising electrode materials for high-performance electrical energy storage devices.
Zhang, Jijun; Li, Jiawei; Tan, Guoguo; Hu, Renchao; Wang, Junqiang; Chang, Chuntao; Wang, Xinmin
2017-12-06
Thin and flexible materials that can provide efficient electromagnetic interference (EMI) shielding are urgently needed, especially if they can be easily processed and withstand harsh environments. Herein, layer-structured Fe-Si-B/Ni-Cu-P metallic glass composites have been developed by simple electroless plating Ni-Cu-P coating on commercial Fe-Si-B metallic glasses. The 0.1 mm-thick composite shows EMI shielding effectiveness of 40 dB over the X-band frequency range, which is higher than those of traditional metals, metal oxides, and their polymer composites of larger thickness. Most of the applied electromagnetic waves are proved to be absorbed rather than bounced back. This performance originates from the combination of a superior soft magnetic property, excellent electrical conductivity, and multiple internal reflections from multilayer composites. In addition, the flexible composites also exhibit good corrosion resistance, high thermal stability, and excellent tensile strength, making them suitable for EMI shielding in harsh chemical or thermal environments.
Frangos, Savvas; Iakovou, Ioannis P; Marlowe, Robert J; Eftychiou, Nicolaos; Patsali, Loukia; Vanezi, Anna; Savva, Androulla; Mpalaris, Vassilis; Giannoula, Evanthia I
2015-12-01
We determined the reasons for radioiodine thyroid remnant ablation, and the procedure's necessity based on postsurgical remnant size, in patients with putatively "low-intermediate-risk" differentiated thyroid carcinoma (DTC). We identified key clinicopathological, treatment and remnant characteristics, and factors associated with remnant size in 336 patients with pT1/2, M0 DTC ablated during the period September 2010 to October 2013 at one Cypriot or one Greek referral centre. Clinicopathological/treatment characteristics were compiled from charts. Experienced nuclear medicine physicians rated the numbers/intensities of uptake foci in the thyroid bed on postablation planar scintigrams using scales of 0-4 points and 0-3 points, respectively. The product of these scores was taken as the "remnant score" that ranged from 0 (no remnant) to 12 (multiple remnants, intense uptake). DTC was predominantly papillary. The median [25th-75th percentile] longest primary tumour diameter was 1.0 cm [0.7-1.5 cm]. Despite favourable histotypes and primary tumour classifications, patients often had preablation characteristics suggesting elevated or uncertain risk: 31.0% of patients (104 of 336) had primary tumour multifocality, 22.0% (74) had confirmed cervical lymph node metastases, 37.2% (125) had unknown nodal status, and 38.1% (128) had antithyroglobulin antibody seropositivity. The median [25th-75th percentile] remnant score was 4 [2-6]; 39.9% of patients (134 of 336) had scores ≥6. For the entire cohort, T or N stages (r ≤ 0.174, P ≤ 0.05) correlated positively with the remnant score in a univariate Spearman analysis. The numbers of patients referred by the surgeon, cervical lymph nodes excised and metastatic nodes excised correlated negatively (r ≤ 0.243, P ≤ 0.038) with the remnant score, and the first two factors independently predicted the remnant score (P ≤ 0.037) in a multivariate analysis. Patients with putatively "low-intermediate-risk" DTC frequently had disease characteristics denoting high or uncertain risk, suggesting that "selective" radioiodine ablation in such patients may seldom be applicable outside international centres of excellence. Proxies for surgeon experience and surgical completeness correlated with remnant number/uptake intensity and may aid ablation-related decision-making.
Yu, Chenfei; Ma, Peipei; Zhou, Xi; Wang, Anqi; Qian, Tao; Wu, Shishan; Chen, Qiang
2014-10-22
Highly dispersed polypyrrole nanowires are decorated on reduced graphene oxide sheets using a facile in situ synthesis route. The prepared composites exhibit high dispersibility, large effective surface area, and high electric conductivity. All-solid-state flexible supercapacitors are assembled based on the prepared composites, which show excellent electrochemical performances with a specific capacitance of 434.7 F g(-1) at a current density of 1 A g(-1). The as-fabricated supercapacitor also exhibits excellent cycling stability (88.1% capacitance retention after 5000 cycles) and exceptional mechanical flexibility. In addition, outstanding power and energy densities were obtained, demonstrating the significant potential of prepared material for flexible and portable energy storage devices.
Wang, Jinrong; Qiao, Jinliang; Wang, Jianfeng; Zhu, Ying; Jiang, Lei
2015-05-06
Due to hierarchical organization of micro- and nanostructures, natural nacre exhibits extraordinary strength and toughness, and thus provides a superior model for the design and fabrication of high-performance artificial composite materials. Although great progress has been made in constructing layered composites by alternately stacking hard inorganic platelets and soft polymers, the real issue is that the excellent strength of these composites was obtained at the sacrifice of toughness. In this work, inspired by the layered aragonite microplatelets/chitin nanofibers-protein structure of natural nacre, alumina microplatelets-graphene oxide nanosheets-poly(vinyl alcohol) (Al2O3/GO-PVA) artificial nacre is successfully constructed through layer-by-layer bottom-up assembly, in which Al2O3 and GO-PVA act as "bricks" and "mortar", respectively. The artificial nacre has hierarchical "brick-and-mortar" structure and exhibits excellent strength (143 ± 13 MPa) and toughness (9.2 ± 2.7 MJ/m(3)), which are superior to those of natural nacre (80-135 MPa, 1.8 MJ/m(3)). It was demonstrated that the multiscale hierarchical structure of ultrathin GO nanosheets and submicrometer-thick Al2O3 platelets can deal with the conflict between strength and toughness, thus leading to the excellent mechanical properties that cannot be obtained using only one size of platelet. We strongly believe that the work presented here provides a creative strategy for designing and developing new composites with excellent strength and toughness.
Liu, Dong; Du, Pengcheng; Wei, Wenli; Wang, Hongxing; Wang, Qi; Liu, Peng
2018-03-01
Polyaniline coated reduced graphene oxide/carbon nanotube composite fibers ((RGO/CNTs)@PANI, RCP) with skeleton/skin structure are designed as fiber-shaped electrodes for high performance all-solid-state symmetric supercapacitor. The one-dimensional reduced graphene oxide/carbon nanotube composite fibers (RGO/CNTs, RC) are prepared via a simple in-situ reduction of graphene oxide in presence of carbon nanotubes in quartz glass pipes, which exhibit excellent mechanical performance of >193.4 MPa of tensile strength. Then polyaniline is coated onto the RC fibers by electrodepositing technique. The electrochemical properties of the RCP fiber-shaped electrodes are optimized by adjusting the feeding ratio of carbon nanotubes. The optimized one exhibits good electrochemical characteristic such as highest volumetric specific capacitance of 193.1 F cm -3 at 1 A cm -3 , as well as excellent cyclic retention of 92.60% after 2000 cyclic voltammetry cycles. Furthermore, the all-solid-state symmetric supercapacitor, fabricated by using the final composite fiber as both positive and negative electrodes pre-coated with the poly(vinyl alcohol)/H 2 SO 4 gel polyelectrolyte, possesses volumetric capacitance of 36.7 F cm -3 at 0.2 A cm -3 and could light up a red light-emitting diode easily. The excellent mechanical and electrochemical performances make the designed supercapacitor as promising high performance wearable energy storage device. Copyright © 2017 Elsevier Inc. All rights reserved.
Machining of glass and quartz using nanosecond and picosecond laser pulses
NASA Astrophysics Data System (ADS)
Ashkenasi, David; Kaszemeikat, Tristan; Mueller, Norbert; Lemke, Andreas; Eichler, Hans Joachim
2012-03-01
New laser processing strategies in micro processing of glass, quartz and other optically transparent materials are being developed with increasing effort. Utilizing diode-pumped solid-state laser generating nanosecond pulsed green (532 nm) laser light in conjunction with either scanners or special trepanning systems can provide for reliable glass machining at excellent efficiency. Micro ablation can be induced either from the front or rear side of the glass sample. Ablation rates of over 100 μm per pulse can be achieved in rear side processing. In comparison, picosecond laser processing of glass and quartz (at a wavelength of 1064 or 532 nm) yield smaller feed rates at however much better surface and bore wall quality. This is of great importance for small sized features, e.g. through-hole diameters smaller 50 μm in thin glass. Critical for applications with minimum micro cracks and maximum performance is an appropriate distribution of laser pulses over the work piece along with optimum laser parameters. Laser machining tasks are long aspect micro drilling, slanted through holes, internal contour cuts, micro pockets and more complex geometries in e.g. soda-lime glass, B33, B270, D236T, AF45 and BK7 glass, quartz, and Zerodur.
Treatment of hyperplastic inferior nasal turbinates by means of a Ho:YAG laser
NASA Astrophysics Data System (ADS)
Sroka, Ronald; Leunig, Andreas; Janda, P.; Rosler, P.; Grevers, G.; Baumgartner, Reinhold
1999-06-01
Although the successful use of the Ho:YAG laser in nasal turbinate surgery had been reported no clinical study had been performed to assess the clinical outcome in longterm. By means of a pulsed Ho:YAG laser emitting at λ=2080nm (1J/pulse, 3-8 Hz) 57 patients suffering from nasal obstruction due to allergic rhinitis and vasomotoric rhinitis were treated under local anesthesia. The study was conducted by standardized questionnaire, photo documentation, allergy test, mucocilliar test, rhinomanometry, radiology and histology. Within 2 weeks after laser treatment a significant improvement of nasal airflow correlating to the extent of the ablated turbinate tissue could be determined. This effect lasted up until 1 year post treatment resulting in an improved quality of life in more than 80 percent of the patients. Side effects like nasal dryness and pain were rare (<4%), no immediate complications were observed. The total treatment time takes 3-8 min and nasal packing was not necessary after the laser procedure. In conclusion Ho:YAG laser treatment can be performed as an outpatient procedure under local anesthesia with excellent ablation of soft tissue in a short treatment time with promising results.
Infrared spectra of the CO2- and C2O4- anions isolated in solid argon
NASA Astrophysics Data System (ADS)
Zhou, Mingfei; Andrews, Lester
1999-02-01
Laser ablation of transition metal targets with concurrent 11 to 12 K condensation of CO2-Ar mixtures produces a sharp metal independent infrared absorption at 1657.0 cm-1 due to CO2-, which is formed from the capture of ablated electrons by CO2 molecules during the condensation process. Two additional metal independent absorptions are produced at 1856.7 and 1184.7 cm-1 on matrix annealing to 25 K to allow diffusion and reaction of CO2 and CO2-. Isotopic substitution (13CO2, C18O2, C16,18O2, and mixtures) shows that these two vibrations involve two equivalent CO2 subunits. The excellent agreement with frequencies, intensities, and isotopic frequency ratios from density-functional calculations supports assignment to the symmetrical C2O4- anion with D2d symmetry. Photodissociation (470-580 nm) and failure to observe these absorptions in identical experiments doped with the electron trapping molecule CCl4 further support the molecular anion assignments. Although absorptions were observed for weak (CO2)(CO2-) complexes, no evidence was found for the asymmetric O2CṡOCO- molecule-anion complex characterized by calculations.
González-Suárez, Ana; Berjano, Enrique; Guerra, Jose M.; Gerardo-Giorda, Luca
2016-01-01
Radiofrequency catheter ablation (RFCA) is a routine treatment for cardiac arrhythmias. During RFCA, the electrode-tissue interface temperature should be kept below 80°C to avoid thrombus formation. Open-irrigated electrodes facilitate power delivery while keeping low temperatures around the catheter. No computational model of an open-irrigated electrode in endocardial RFCA accounting for both the saline irrigation flow and the blood motion in the cardiac chamber has been proposed yet. We present the first computational model including both effects at once. The model has been validated against existing experimental results. Computational results showed that the surface lesion width and blood temperature are affected by both the electrode design and the irrigation flow rate. Smaller surface lesion widths and blood temperatures are obtained with higher irrigation flow rate, while the lesion depth is not affected by changing the irrigation flow rate. Larger lesions are obtained with increasing power and the electrode-tissue contact. Also, larger lesions are obtained when electrode is placed horizontally. Overall, the computational findings are in close agreement with previous experimental results providing an excellent tool for future catheter research. PMID:26938638
NASA Astrophysics Data System (ADS)
Yu, Cheng-Chian; Ho, Jeng-Rong
2015-12-01
Based on the techniques of laser microdrilling and solvent reflow, this study reports on a straightforward approach for fabricating plastic microlens arrays (MLAs). First, we use the ArF excimer laser to drill microholes on a polymethylmethacrylate plate for defining the lens number, initial depth, and diameter. The propylene glycol monomethyl ether acetate solvent is then employed to regulate the surface profile that leads to a resulting negative (concave) MLA. The corresponding positive (convex), polydimethyl-siloxane MLA is obtained by the soft-replica-molding technique. Through varying the pattern size and period on the mask and the light intensity for laser drilling and regulating the solvent in the reflow process, we exhibit the feasibility of making MLAs with various sizes and shapes. By modifying the laser ablation step to drill two microholes with different diameters and depths at two levels, we fabricate a bifocal microlens. The obtained microlenses have excellent surface and optical properties: surface roughness down to several nanometers and focal lengths varying from hundreds to thousands of micrometers. This approach is flexible for constructing microlenses with various sizes and shapes and can fabricate MLAs with a high fill factor.
Hybrid micromachining using a nanosecond pulsed laser and micro EDM
NASA Astrophysics Data System (ADS)
Kim, Sanha; Kim, Bo Hyun; Chung, Do Kwan; Shin, Hong Shik; Chu, Chong Nam
2010-01-01
Micro electrical discharge machining (micro EDM) is a well-known precise machining process that achieves micro structures of excellent quality for any conductive material. However, the slow machining speed and high tool wear are main drawbacks of this process. Though the use of deionized water instead of kerosene as a dielectric fluid can reduce the tool wear and increase the machine speed, the material removal rate (MRR) is still low. In contrast, laser ablation using a nanosecond pulsed laser is a fast and non-wear machining process but achieves micro figures of rather low quality. Therefore, the integration of these two processes can overcome the respective disadvantages. This paper reports a hybrid process of a nanosecond pulsed laser and micro EDM for micromachining. A novel hybrid micromachining system that combines the two discrete machining processes is introduced. Then, the feasibility and characteristics of the hybrid machining process are investigated compared to conventional EDM and laser ablation. It is verified experimentally that the machining time can be effectively reduced in both EDM drilling and milling by rapid laser pre-machining prior to micro EDM. Finally, some examples of complicated 3D micro structures fabricated by the hybrid process are shown.
Clinical use of a 15-W diode laser in small animal surgery: results in 30 varied procedures
NASA Astrophysics Data System (ADS)
Crowe, Dennis T.; Swalander, David; Hittenmiller, Donald; Newton, Jenifer
1999-06-01
The use of a 15-watt diode laser (CeramOptec)in 30 surgical procedures in dogs and cats was reviewed. Ease of use, operator safety, hemostasis control, wound healing, surgical time, complication rate, and pain control were observed and recorded. Procedures performed were partial pancreatectomy, nasal carcinoma ablation, medial meniscus channeling, perianal and anorectal mass removal (5), hemangioma and hemangiopericytoma removal from two legs, benign skin mass removal (7), liver lobectomy, partial prostatectomy, soft palate resection, partial arytenoidectomy, partial ablation of a thyroid carcinoma, photo-vaporization of the tumor bed following malignant tumor resection (4), neurosheath tumor removal from the tongue, tail sebaceous cyst resection, malignant mammary tumor and mast cell tumor removal. The laser was found to be very simple and safe to use. Hemostasis was excellent in all but the liver and prostate surgeries. The laser was particularly effective in preventing hemorrhage during perianal, anal, and tongue mass removal. It is estimated that a time and blood loss savings of 50% over that of conventional surgery occurred with the use of the laser. All external wounds made by laser appeared to heal faster and with less inflammation than those made with a conventional or electrosurgical scalpel.
Chen, Junchen; Wang, Yaming; Cao, Jianyun; Liu, Yan; Zhou, Yu; Ouyang, Jia-Hu; Jia, Dechang
2017-06-14
A facile co-electrodeposition method has been developed to fabricate reduced graphene oxide/polypyrrole (rGO/PPy) composite films, with sodium dodecyl benzene sulfonate as both a surfactant and supporting electrolyte in the precursor solution. The introduction of rGO into the PPy films forms porous structure and enhances the conductivity across the film, leading to superior electrochemical performance. By controlling the deposition time and rGO concentration, the highest area capacitance can reach 411 mF/cm 2 (0.2 mA/cm 2 ) for rGO/PPy films, whereas optimized specific capacitance is as high as 361 F/g (0.2 mA/cm 2 ). All of the composite films exhibit excellent rate capability (at least 175 F/g at the current density of 12 mA/cm 2 ) compared with pure PPy film (only 12 F/g at the current density of 12 mA/cm 2 ). The rGO/PPy composite exhibits excellent cycling stability that maintains 104% of its initial capacitance after cycling for 2000 cycles and 80% for 5000 cycles. The two-electrode solid-state supercapacitor (SC) based on rGO/PPy composite electrodes demonstrates good rate performance, excellent cycling stability, as well as a high area capacitance of 222 mF/cm 2 . The solid-state planar SC based on the rGO/PPy composite exhibits an area capacitance of 9.4 mF/cm 2 , demonstrating great potential for fabrication of microsupercapacitors.
Martin, Gregory G.; Atshaves, Barbara P.; Landrock, Kerstin K.; Landrock, Danilo; Storey, Stephen M.; Howles, Philip N.; Kier, Ann B.
2014-01-01
On the basis of their abilities to bind bile acids and/or cholesterol, the physiological role(s) of liver fatty acid-binding protein (L-FABP) and sterol carrier protein (SCP) 2/SCP-x (SCP-2/SCP-x) gene products in biliary bile acid and cholesterol formation was examined in gene-ablated male mice. L-FABP (LKO) or L-FABP/SCP-2/SCP-x [triple-knockout (TKO)] ablation markedly decreased hepatic bile acid concentration, while SCP-2/SCP-x [double-knockout (DKO)] ablation alone had no effect. In contrast, LKO increased biliary bile acid, while DKO and TKO had no effect on biliary bile acid levels. LKO and DKO also altered biliary bile acid composition to increase bile acid hydrophobicity. Furthermore, LKO and TKO decreased hepatic uptake and biliary secretion of high-density lipoprotein (HDL)-derived 22-(N-(7-nitrobenz-2-oxa-1,3-diazol-4-yl)amino)-23,24-bisnor-5-cholen-3β-ol (NBD-cholesterol), while DKO alone had no effect. Finally, LKO and, to a lesser extent, DKO decreased most indexes contributing to cholesterol solubility in biliary bile. These results suggest different, but complementary, roles for L-FABP and SCP-2/SCP-x in biliary bile acid and cholesterol formation. L-FABP appears to function more in hepatic retention of bile acids as well as hepatic uptake and biliary secretion of HDL-cholesterol. Conversely, SCP-2/SCP-x may function more in formation and biliary secretion of bile acid, with less impact on hepatic uptake or biliary secretion of HDL-cholesterol. PMID:25277800
NASA Technical Reports Server (NTRS)
Foote, M. C.; Jones, B. B.; Hunt, B. D.; Barner, J. B.; Vasquez, R. P.; Bajuk, L. J.
1992-01-01
The composition of pulsed-ultraviolet-laser-deposited Y-Ba-Cu-O films was examined as a function of position across the substrate, laser fluence, laser spot size, substrate temperature, target conditioning, oxygen pressure and target-substrate distance. Laser fluence, laser spot size, and substrate temperature were found to have little effect on composition within the range investigated. Ablation from a fresh target surface results in films enriched in copper and barium, both of which decrease in concentration until a steady state condition is achieved. Oxygen pressure and target-substrate distance have a significant effect on film composition. In vacuum, copper and barium are slightly concentrated at the center of deposition. With the introduction of an oxygen background pressure, scattering results in copper and barium depletion in the deposition center, an effect which increases with increasing target-substrate distance. A balancing of these two effects results in stoichiometric deposition.
Kuznetsov, Ilya; Filevich, Jorge; Dong, Feng; Woolston, Mark; Chao, Weilun; Anderson, Erik H.; Bernstein, Elliot R.; Crick, Dean C.; Rocca, Jorge J.; Menoni, Carmen S.
2015-01-01
Analytical probes capable of mapping molecular composition at the nanoscale are of critical importance to materials research, biology and medicine. Mass spectral imaging makes it possible to visualize the spatial organization of multiple molecular components at a sample's surface. However, it is challenging for mass spectral imaging to map molecular composition in three dimensions (3D) with submicron resolution. Here we describe a mass spectral imaging method that exploits the high 3D localization of absorbed extreme ultraviolet laser light and its fundamentally distinct interaction with matter to determine molecular composition from a volume as small as 50 zl in a single laser shot. Molecular imaging with a lateral resolution of 75 nm and a depth resolution of 20 nm is demonstrated. These results open opportunities to visualize chemical composition and chemical changes in 3D at the nanoscale. PMID:25903827
Continuous composition-spread thin films of transition metal oxides by pulsed-laser deposition
NASA Astrophysics Data System (ADS)
Ohkubo, I.; Christen, H. M.; Khalifah, P.; Sathyamurthy, S.; Zhai, H. Y.; Rouleau, C. M.; Mandrus, D. G.; Lowndes, D. H.
2004-02-01
We have designed an improved pulsed-laser deposition-continuous composition-spread (PLD-CCS) system that overcomes the difficulties associated with earlier related techniques. Our new PLD-CCS system is based on a precisely controlled synchronization between the laser firing, target exchange, and substrate translation/rotation, and offers more flexibility and control than earlier PLD-based approaches. Most importantly, the deposition energetics and the film thickness are kept constant across the entire composition range, and the resulting samples are sufficiently large to allow characterization by conventional techniques. We fabricated binary alloy composition-spread films composed of SrRuO 3 and CaRuO 3. Alternating ablation from two different ceramic targets leads to in situ alloy formation, and the value of x in Sr xCa x-1 RuO 3 can be changed linearly from 0 to 1 (or over any arbitrarily smaller range) along one direction of the substrate.
Microstructural analysis of W-SiCf/SiC composite
NASA Astrophysics Data System (ADS)
Yoon, Hanki; Oh, Jeongseok; Kim, Gonho; Kim, Hyunsu; Takahashi, Heishichiro; Kohyama, Akira
2015-03-01
Continuous silicon carbide fiber-reinforced silicon carbide (SiCf/SiC) composites are promising structure candidates for future fusion power systems such as gas coolant fast channels, extreme high temperature reactor and fusion reactors, because of their intrinsic properties such as excellent mechanical properties, high thermal conductivity, good thermal-shock resistance as well as excellent physical and chemical stability in various environments under elevated temperature conditions. In this study, bonding of tungsten and SiCf/SiC was produced by hot-press method. Microstructure analyses were performed using SEM and TEM.
Preparing composite materials from matrices of processable aromatic polyimide thermoplastic blends
NASA Technical Reports Server (NTRS)
Johnston, Norman J. (Inventor); St.clair, Terry L. (Inventor); Baucom, Robert M. (Inventor); Gleason, John R. (Inventor)
1991-01-01
Composite materials with matrices of tough, thermoplastic aromatic polyimides are obtained by blending semi-crystalline polyimide powders with polyamic acid solutions to form slurries, which are used in turn to prepare prepregs, the consolidation of which into finished composites is characterized by excellent melt flow during processing.
High resolution analysis of soil elements with laser-induced breakdown
Ebinger, Michael H [Santa Fe, NM; Harris, Ronny D [Los Alamos, NM
2010-04-06
The invention is a system and method of detecting a concentration of an element in a soil sample wherein an opening or slot is formed in a container that supports a soil sample that was extracted from the ground whereupon at least a length of the soil sample is exposed via the opening. At each of a plurality of points along the exposed length thereof, the soil sample is ablated whereupon a plasma is formed that emits light characteristic of the elemental composition of the ablated soil sample. Each instance of emitted light is separated according to its wavelength and for at least one of the wavelengths a corresponding data value related to the intensity of the light is determined. As a function of each data value a concentration of an element at the corresponding point along the length of the soil core sample is determined.
Low work function, stable thin films
Dinh, Long N.; McLean, II, William; Balooch, Mehdi; Fehring, Jr., Edward J.; Schildbach, Marcus A.
2000-01-01
Generation of low work function, stable compound thin films by laser ablation. Compound thin films with low work function can be synthesized by simultaneously laser ablating silicon, for example, and thermal evaporating an alkali metal into an oxygen environment. For example, the compound thin film may be composed of Si/Cs/O. The work functions of the thin films can be varied by changing the silicon/alkali metal/oxygen ratio. Low work functions of the compound thin films deposited on silicon substrates were confirmed by ultraviolet photoelectron spectroscopy (UPS). The compound thin films are stable up to 500.degree. C. as measured by x-ray photoelectron spectroscopy (XPS). Tests have established that for certain chemical compositions and annealing temperatures of the compound thin films, negative electron affinity (NEA) was detected. The low work function, stable compound thin films can be utilized in solar cells, field emission flat panel displays, electron guns, and cold cathode electron guns.
NASA Technical Reports Server (NTRS)
Norman, M.; McCulloch, M.; ONeill, H.; Brandon, A.
2004-01-01
Magnesium isotopes potentially offer new insights into a diverse range of processes including evaporation and condensation in the solar nebula, melting and metasomatism in planetary interiors, and hydrothermal alteration [1,2,3,4]. Volatility-related Mg isotopic variations of up to 10 per mil/amu relative to a terrestrial standard have been found in early nebular phases interpreted as evaporation residues [1], and relatively large variations (up to 3 per mil/amu) in the terrestrial mantle have been reported recently [4]. In order to investigate possible differences in the nebular history of material contributing to the terrestrial planets, and to search for evidence of a high-temperature origin of the Moon, we have measured the magnesium isotopic composition of primitive olivines from the Earth, Moon, Mars, and pallasite parent body using laser-ablation multicollector ICPMS.
NASA Astrophysics Data System (ADS)
Cheng, Zhenxiang; Kannan, Chinna Venkatasamy; Ozawa, Kiyoshi; Kimura, Hideo; Wang, Xiaolin
2006-07-01
Samarium doped bismuth titanate thin films with the composition of Bi3.25Sm0.75Ti3O12 and with strong preferred orientations along the c axis and the (117) direction were fabricated on Pt /TiO2/SiO2/Si substrate by pulsed laser ablation. Measurements on Pt /BSmT/Pt capacitors showed that the c-axis oriented film had a small remanent polarization (2Pr) of 5μC/cm2, while the highly (117) oriented film showed a 2Pr value of 54μC/cm2 at an electrical field of 268kV/cm and a coercive field Ec of 89kV/cm. This is different from the sol-gel derived c-axis oriented Bi3.15Sm0.85Ti3O12 film showing a 2Pr value of 49μC/cm2.
Hondrogiannis, Ellen M; Ehrlinger, Erin; Poplaski, Alyssa; Lisle, Meredith
2013-11-27
A total of 11 elements found in 25 vanilla samples from Uganda, Madagascar, Indonesia, and Papua New Guinea were measured by laser ablation-inductively coupled plasma-time-of-flight-mass spectrometry (LA-ICP-TOF-MS) for the purpose of collecting data that could be used to discriminate among the origins. Pellets were prepared of the samples, and elemental concentrations were obtained on the basis of external calibration curves created using five National Institute of Standards and Technology (NIST) standards and one Chinese standard with (13)C internal standardization. These curves were validated using NIST 1573a (tomato leaves) as a check standard. Discriminant analysis was used to successfully classify the vanilla samples by their origin. Our method illustrates the feasibility of using LA-ICP-TOF-MS with an external calibration curve for high-throughput screening of spice screening analysis.
NASA Technical Reports Server (NTRS)
Valentine, Peter G.; Lawrence, Timothy W.; Gubert, Michael K.; Milos, Frank S.; Kiser, James D.; Ohlhorst, Craig W.; Koenig, John R.
2006-01-01
As a collaborative effort among NASA Centers, the "Lightweight Nonmetallic Thermal Protection Materials Technology" Project was set up to assist mission/vehicle design trade studies, to support risk reduction in thermal protection system (TPS) material selections, to facilitate vehicle mass optimization, and to aid development of human-rated TPS qualification and certification plans. Missions performing aerocapture, aerobraking, or direct aeroentry rely on advanced heatshields that allow reductions in spacecraft mass by minimizing propellant requirements. Information will be presented on candidate materials for such reentry approaches and on screening tests conducted (material property and space environmental effects tests) to evaluate viable candidates. Seventeen materials, in three classes (ablatives, tiles, and ceramic matrix composites), were studied. In additional to physical, mechanical, and thermal property tests, high heat flux laser tests and simulated-reentry oxidation tests were performed. Space environmental effects testing, which included exposures to electrons, atomic oxygen, and hypervelocity impacts, was also conducted.
NASA Technical Reports Server (NTRS)
Erickson, W. D.; Sullivan, E. M. (Inventor)
1973-01-01
An ablation article, such as a conical heat shield, having an ablating surface is provided with at least one discrete area of at least one seed material, such as aluminum. When subjected to ablation conditions, the seed material is ablated. Radiation emanating from the ablated seed material is detected to analyze ablation effects without disturbing the ablation surface. By providing different seed materials having different radiation characteristics, the ablating effects on various areas of the ablating surface can be analyzed under any prevailing ablation conditions. The ablating article can be provided with means for detecting the radiation characteristics of the ablated seed material to provide a self-contained analysis unit.
1987-04-22
absorptivity in the presence of scatteringsc B Defined in equation (40) B wBE Diffuse surface radiosity C Mass fraction of injected species D. jiCoefficient of...Then 20 A eb)x 8 eb- (49) where B and B., are the surface radiosities . It follows invnediately that wX 0 T to d 2e (50) ~ f ~ b W 2 L 3 ( ) 2 1 - 1
Major uncertainties influencing entry probe heat shield design
NASA Technical Reports Server (NTRS)
Congdon, W.
1974-01-01
Factors influencing the design of an outer planet probe heat shield are discussed. Major factors included are: uncertainties in composition and scale height of the planet atmospheres; the augmentation/attenuation of entry heating by ablation products requires more computer study and testing; carbon heat shields, especially carbon phenolic, possessing improved resistance to spallation need developing; and white silica reflecting heat shields with improved resistance to bulk vitrification need further developing.
Design considerations for a pressure-driven multi-stage rocket
NASA Astrophysics Data System (ADS)
Sauerwein, Steven Craig
2002-01-01
The purpose of this study was to examine the feasibility of using propellant tank pressurization to eliminate the use of high-pressure turbopumps in multi-stage liquid-fueled satellite launchers. Several new technologies were examined to reduce the mass of such a rocket. Composite materials have a greater strength-to-weight ratio than metals and can be used to reduce the weight of rocket propellant tanks and structure. Catalytically combined hydrogen and oxygen can be used to heat pressurization gas, greatly reducing the amount of gas required. Ablatively cooled rocket engines can reduce the complexity and cost of the rocket. Methods were derived to estimate the mass of the various rocket components. These included a method to calculate the amount of gas needed to pressurize a propellant tank by modeling the behavior of the pressurization gas as the liquid propellant flows out of the tank. A way to estimate the mass and size of a ablatively cooled composite cased rocket engine. And a method to model the flight of such a rocket through the atmosphere in conjunction with optimization of the rockets trajectory. The results show that while a liquid propellant rocket using tank pressurization are larger than solid propellant rockets and turbopump driven liquid propellant rockets, they are not impractically large.
NASA Astrophysics Data System (ADS)
Londero, Pablo
The characterization of artistic practice throughout history often requires measurements of material composition with microscopic resolution, either due to the fine detail of the material composition or to the amount of sample available. This problem is exacerbated for the detection of organic colorants, which are often embedded in a complex matrix (e.g. oil, natural fibers) and in low concentration due to their high tinting strength. Surface-Enhanced Raman Spectroscopy (SERS) is increasingly used in detection of organic colorants in cultural heritage due to its high sensitivity and inherent preferential sensitivity to small organic molecules. This talk will discuss recent results from a new SERS measurement technique, in which laser ablation is used as a micro-sampling method onto a SERS-active film to characterize art samples with microscopic precision and sensitivity comparable to many mass spectrometry measurements. Furthermore, the nature of the sampling method provides built-in benefits to other SERS-based techniques, such as more quantitative characterization of mixtures, improved sensitivity to some analytes, and reduced background interference. Examples will be shown for measurements of reference materials and art objects, including a restored 16th-century dish and a Renaissance fresco, The Incredulity of San Thomas, by Luca Signorelli. Supported by the National Science Foundation (NSF-CHE-1402750).
A new pulsed laser deposition technique: scanning multi-component pulsed laser deposition method.
Fischer, D; de la Fuente, G F; Jansen, M
2012-04-01
The scanning multi-component pulsed laser deposition (PLD) method realizes uniform depositions of desired coatings by a modified pulsed laser deposition process, preferably with a femto-second laser-system. Multi-component coatings (single or multilayered) are thus deposited onto substrates via laser induced ablation of segmented targets. This is achieved via horizontal line-scanning of a focused laser beam over a uniformly moving target's surface. This process allows to deposit the desired composition of the coating simultaneously, starting from the different segments of the target and adjusting the scan line as a function of target geometry. The sequence and thickness of multilayers can easily be adjusted by target architecture and motion, enabling inter/intra layer concentration gradients and thus functional gradient coatings. This new, simple PLD method enables the achievement of uniform, large-area coatings. Case studies were performed with segmented targets containing aluminum, titanium, and niobium. Under the laser irradiation conditions applied, all three metals were uniformly ablated. The elemental composition within the rough coatings obtained was fixed by the scanned area to Ti-Al-Nb = 1:1:1. Crystalline aluminum, titanium, and niobium were found to coexist side by side at room temperature within the substrate, without alloy formation up to 600 °C. © 2012 American Institute of Physics
Gold nanostar synthesis with a silver seed mediated growth method.
Kereselidze, Zurab; Romero, Victor H; Peralta, Xomalin G; Santamaria, Fidel
2012-01-15
The physical, chemical and optical properties of nano-scale colloids depend on their material composition, size and shape. There is a great interest in using nano-colloids for photo-thermal ablation, drug delivery and many other biomedical applications. Gold is particularly used because of its low toxicity. A property of metal nano-colloids is that they can have a strong surface plasmon resonance. The peak of the surface plasmon resonance mode depends on the structure and composition of the metal nano-colloids. Since the surface plasmon resonance mode is stimulated with light there is a need to have the peak absorbance in the near infrared where biological tissue transmissivity is maximal. We present a method to synthesize star shaped colloidal gold, also known as star shaped nanoparticles or nanostars. This method is based on a solution containing silver seeds that are used as the nucleating agent for anisotropic growth of gold colloids. Scanning electron microscopy (SEM) analysis of the resulting gold colloid showed that 70 % of the nanostructures were nanostars. The other 30 % of the particles were amorphous clusters of decahedra and rhomboids. The absorbance peak of the nanostars was detected to be in the near infrared (840 nm). Thus, our method produces gold nanostars suitable for biomedical applications, particularly for photo-thermal ablation.
In Situ Measurements of Meteoric Ions. Chapter 8
NASA Technical Reports Server (NTRS)
Grebowsky, Joseph M.; Aikin, Arthur C.; Vondrak, Richard R. (Technical Monitor)
2001-01-01
Metal ions found in the atmosphere above 60 km are the result of incoming meteoroid atmospheric ablation. Layers of metal ions are detected by sounding rocket in situ mass spectrometric sampling in the 80 to 130 km region, which coincides with the altitude region where meteors are observed. Enhancements of metal ion concentrations occur during meteor showers. Even outside of shower periods, the metal ion altitude profiles vary from measurement to measurement. Double layers are frequent at middle latitudes. More than 40 different meteoric atomic and molecular ions, including isotopes, have been detected. Atmospheric metal ions on average have an abundance that matches chrondritic material, the same composition as the early solar system. However there are frequently local departures from this composition due to differential ablation, species dependent chemistry and mass dependent ion transport. Metal ions react with atmospheric O2, O, O3, H2O and H2O2 to form oxygenated and hydrogenated ionic compounds. Metal atomic ions at high altitudes have long lifetimes. As a result, these ions, in the presence of Earth's magnetic field, are transported over long distances by upper atmospheric winds and ionospheric electric fields. Satellite measurements have detected metal ions as high as, approximately 1000 km and have revealed circulation of the ions on a global scale.
Explosive bonding of metal-matrix composites
NASA Technical Reports Server (NTRS)
Reece, O. Y.
1969-01-01
Explosive bonding process produces sheet composites of aluminum alloy reinforced by high-strength stainless steel wires. The bonds are excellent metallurgically, no external heat is required, various metals can be bonded, and the process is inexpensive.
NASA Technical Reports Server (NTRS)
Nanzetta, Philip
1992-01-01
The U.S. Navy has had an active Manufacturing Technology (MANTECH) Program aimed at developing advanced production processes and equipment since the late-1960's. During the past decade, however, the resources of the MANTECH program were concentrated in Centers of Excellence. Today, the Navy sponsors four manufacturing technology Centers of Excellence: the Automated Manufacturing Research Facility (AMRF); the Electronics Manufacturing Productivity Facility (EMPF); the National Center for Excellence in Metalworking Technology (NCEMT); and the Center of Excellence for Composites Manufacturing Technology (CECMT). This paper briefly describes each of the centers and summarizes typical Intelligent Equipment Processing (IEP) projects that were undertaken.
Graphene-copper composite with micro-layered grains and ultrahigh strength
Wang, Lidong; Yang, Ziyue; Cui, Ye; Wei, Bing; Xu, Shichong; Sheng, Jie; Wang, Miao; Zhu, Yunpeng; Fei, Weidong
2017-01-01
Graphene with ultrahigh intrinsic strength and excellent thermal physical properties has the potential to be used as the reinforcement of many kinds of composites. Here, we show that very high tensile strength can be obtained in the copper matrix composite reinforced by reduced graphene oxide (RGO) when micro-layered structure is achieved. RGO-Cu powder with micro-layered structure is fabricated from the reduction of the micro-layered graphene oxide (GO) and Cu(OH)2 composite sheets, and RGO-Cu composites are sintered by spark plasma sintering process. The tensile strength of the 5 vol.% RGO-Cu composite is as high as 608 MPa, which is more than three times higher than that of the Cu matrix. The apparent strengthening efficiency of RGO in the 2.5 vol.% RGO-Cu composite is as high as 110, even higher than that of carbon nanotube, multilayer graphene, carbon nano fiber and RGO in the copper matrix composites produced by conventional MLM method. The excellent tensile and compressive strengths, high hardness and good electrical conductivity are obtained simultaneously in the RGO-Cu composites. The results shown in the present study provide an effective method to design graphene based composites with layered structure and high performance. PMID:28169306
NASA Astrophysics Data System (ADS)
Yang, Qi; Lan, Fang; Yi, Qiangying; Wu, Yao; Gu, Zhongwei
2015-10-01
A combination strategy of the inverse emulsion crosslinking approach and the colloidal assembly technique is first proposed to synthesize Fe3O4/histidine composite nanoclusters as new-type magnetic porous nanomaterials. The nanoclusters possess uniform morphology, high magnetic content and excellent protein adsorption capacity, exhibiting their great potential for bio-separation.A combination strategy of the inverse emulsion crosslinking approach and the colloidal assembly technique is first proposed to synthesize Fe3O4/histidine composite nanoclusters as new-type magnetic porous nanomaterials. The nanoclusters possess uniform morphology, high magnetic content and excellent protein adsorption capacity, exhibiting their great potential for bio-separation. Electronic supplementary information (ESI) available: Experimental details. See DOI: 10.1039/c5nr05800g
NASA Astrophysics Data System (ADS)
Tulej, Marek; Wiesendanger, Reto; Neuland, Maike; Meyer, Stefan; Wurz, Peter; Neubeck, Anna; Ivarsson, Magnus; Riedo, Valentine; Moreno-Garcia, Pavel; Riedo, Andreas; Knopp, Gregor
2017-04-01
Investigation of elemental and isotope compositions of planetary solids with high spatial resolution are of considerable interest to current space research. Planetary materials are typically highly heterogenous and such studies can deliver detailed chemical information of individual sample components with the sizes down to a few micrometres. The results of such investigations can yield mineralogical surface context including mineralogy of individual grains or the elemental composition of of other objects embedded in the sample surface such as micro-sized fossils. The identification of bio-relevant material can follow by the detection of bio-relevant elements and their isotope fractionation effects [1, 2]. For chemical analysis of heterogenous solid surfaces we have combined a miniature laser ablation mass spectrometer (LMS) (mass resolution (m/Dm) 400-600; dynamic range 105-108) with in situ microscope-camera system (spatial resolution ˜2um, depth 10 um). The microscope helps to find the micrometre-sized solids across the surface sample for the direct mass spectrometric analysis by the LMS instrument. The LMS instrument combines an fs-laser ion source and a miniature reflectron-type time-of-flight mass spectrometer. The mass spectrometric analysis of the selected on the sample surface objects followed after ablation, atomisation and ionisation of the sample by a focussed laser radiation (775 nm, 180 fs, 1 kHz; the spot size of ˜20 um) [4, 5, 6]. Mass spectra of almost all elements (isotopes) present in the investigated location are measured instantaneously. A number of heterogenous rock samples containing micrometre-sized fossils and mineralogical grains were investigated with high selectivity and sensitivity. Chemical analyses of filamentous structures observed in carbonate veins (in harzburgite) and amygdales in pillow basalt lava can be well characterised chemically yielding elemental and isotope composition of these objects [7, 8]. The investigation can be prepared with high selectivity since the host composition is typically readily different comparing to that of the analysed objects. In depth chemical analysis (chemical profiling) is found in particularly helpful allowing relatively easy isolation of the chemical composition of the host from the investigated objects [6]. Hence, both he chemical analysis of the environment and microstructures can be derived. Analysis of the isotope compositions can be measured with high level of confidence, nevertheless, presence of cluster of similar masses can make sometimes this analysis difficult. Based on this work, we are confident that similar studies can be conducted in situ planetary surfaces delivering important chemical context and evidences on bio-relevant processes. [1] Summons et al., Astrobiology, 11, 157, 2011. [2] Wurz et al., Sol. Sys. Res. 46, 408, 2012. [3] Riedo et al., J. Anal. Atom. Spectrom. 28, 1256, 2013. [4] Riedo et al., J. Mass Spectrom.48, 1, 2013. [5] Tulej et al., Geostand. Geoanal. Res., 38, 423, 2014. [6] Grimaudo et al., Anal. Chem. 87, 2041, 2015 [7] Tulej et al., Astrobiology, 15, 1, 2015. [8] Neubeck et al., Int. J. Astrobiology, 15, 133, 2016.
Formation of aggregated nanoparticle spheres through femtosecond laser surface processing
NASA Astrophysics Data System (ADS)
Tsubaki, Alfred T.; Koten, Mark A.; Lucis, Michael J.; Zuhlke, Craig; Ianno, Natale; Shield, Jeffrey E.; Alexander, Dennis R.
2017-10-01
A detailed structural and chemical analysis of a class of self-organized surface structures, termed aggregated nanoparticle spheres (AN-spheres), created using femtosecond laser surface processing (FLSP) on silicon, silicon carbide, and aluminum is reported in this paper. AN-spheres are spherical microstructures that are 20-100 μm in diameter and are composed entirely of nanoparticles produced during femtosecond laser ablation of material. AN-spheres have an onion-like layered morphology resulting from the build-up of nanoparticle layers over multiple passes of the laser beam. The material properties and chemical composition of the AN-spheres are presented in this paper based on scanning electron microscopy (SEM), focused ion beam (FIB) milling, transmission electron microscopy (TEM), and energy dispersive x-ray spectroscopy (EDX) analysis. There is a distinct difference in the density of nanoparticles between concentric rings of the onion-like morphology of the AN-sphere. Layers of high-density form when the laser sinters nanoparticles together and low-density layers form when nanoparticles redeposit while the laser ablates areas surrounding the AN-sphere. The dynamic nature of femtosecond laser ablation creates a variety of nanoparticles that make-up the AN-spheres including Si/C core-shell, nanoparticles that directly fragmented from the base material, nanoparticles with carbon shells that retarded oxidation, and amorphous, fully oxidized nanoparticles.
Fu, Jiali; Hu, Zhaochu; Zhang, Wen; Yang, Lu; Liu, Yongsheng; Li, Ming; Zong, Keqing; Gao, Shan; Hu, Shenghong
2016-03-10
The sulfur isotope is an important geochemical tracer in diverse fields of geosciences. In this study, the effects of three different cone combinations with the addition of N2 on the performance of in situ S isotope analyses were investigated in detail. The signal intensities of S isotopes were improved by a factor of 2.3 and 3.6 using the X skimmer cone combined with the standard sample cone or the Jet sample cone, respectively, compared with the standard arrangement (H skimmer cone combined with the standard sample cone). This signal enhancement is important for the improvement of the precision and accuracy of in situ S isotope analysis at high spatial resolution. Different cone combinations have a significant effect on the mass bias and mass bias stability for S isotopes. Poor precisions of S isotope ratios were obtained using the Jet and X cones combination at their corresponding optimum makeup gas flow when using Ar plasma only. The addition of 4-8 ml min(-1) nitrogen to the central gas flow in laser ablation MC-ICP-MS was found to significantly enlarge the mass bias stability zone at their corresponding optimum makeup gas flow in these three different cone combinations. The polyatomic interferences of OO, SH, OOH were also significantly reduced, and the interference free plateaus of sulfur isotopes became broader and flatter in the nitrogen mode (N2 = 4 ml min(-1)). However, the signal intensity of S was not increased by the addition of nitrogen in this study. The laser fluence and ablation mode had significant effects on sulfur isotope fractionation during the analysis of sulfides and elemental sulfur by laser ablation MC-ICP-MS. The matrix effect among different sulfides and elemental sulfur was observed, but could be significantly reduced by line scan ablation in preference to single spot ablation under the optimized fluence. It is recommended that the d90 values of the particles in pressed powder pellets for accurate and precise S isotope analysis should be less than 10 μm. Under the selected optimized analytical conditions, excellent agreements between the determined values and the reference values were achieved for the IAEA-S series standard reference materials and a set of six well-characterized, isotopic homogeneous sulfide standards (PPP-1, MoS2, MASS-1, P-GBW07267, P-GBW07268, P-GBW07270), validating the capability of the developed method for providing high-quality in situ S isotope data in sulfides and elemental sulfur. Copyright © 2016. Published by Elsevier B.V.
An improved processible acetylene-terminated polyimide for composites
NASA Technical Reports Server (NTRS)
Landis, A. L.; Naselow, A. B.
1985-01-01
The newest member of a family of thermosetting acetylene-substituted polyimide oligomers is HR600P. This oligomer is the isoimide version of the oligomer known as HR600P and Thermid 600. Although both types of material yield the same heat resistant end products after cure, HR600P has much superior processing characteristics. This attributed to its lower melting temperature (160 + or - 10 C, 320 + or - 20 F) in contrast to 202 C (396 F) for Thermid MC-600, its longer gel time at its processing temperature (16 to 30 minutes bvs 3 minutes), and its excellent solubility in low boiling solvents such as tetrahydrofuran, glymes, or 4:1 methyl ethyl ketone/toluene mixtures. These advantages provide more acceptable coating and impregnation procedures, allow for more complete removal at lower temperatures, provide a longer pot life or working time, and allow composite structure fabrication in conventional autoclaves used for epoxy composite curing. The excellent processing characteristics of HR600P allow its use in large area laminated structures, structural composites, and molding compositions.
NASA Astrophysics Data System (ADS)
Khan, Rashid; Habib, Muhammad; Gondal, Mohammed A.; Khalil, Adnan; Rehman, Zia Ur; Muhammad, Zahir; Haleem, Yasir A.; Wang, Changda; Wu, Chuan Qiang; Song, Li
2017-10-01
We report the synthesis of CuFe2O4-Fe2O3 composite material for efficient and highly stable supercapacitor electrode by using eco-friendly low-temperature co-precipitation method. The CuFe2O4-Fe2O3 composite demonstrated the highest specific capacitance of 638.24 F g-1 and excellent stability up to 2000 charge/discharge cycles. The achieved capacitance value is 16 times higher than that of pure CuFe2O4. The results revealed the extraordinary performance of CuFe2O4-Fe2O3 composite as supercapacitor electrode with excellent retention in comparison to CuFe2O4. The enhanced electrochemical activity of CuFe2O4-Fe2O3 composite is attributed to the synergistic effect which is responsible for redox coupling between Cu2+ and Fe3+ that has never been achieved by single component before.
NASA Astrophysics Data System (ADS)
Qiang, Wei; Wei, Li; Shaodan, Wang; Yu, Bai
2015-08-01
The precise measurement of quartz crystal microbalance (QCM) in the detection and weighing of organic gas molecules is achieved due to excellent superhydrophobicity of a deposited film composite. Photocatalysis is utilized as a method for the self-cleaning of organic molecules on the QCM for extended long-term stability in the precision of the instrument. In this paper, ZnO nanorod array is prepared via in situ methods on the QCM coated with Au film via hydrothermal process. Subsequently, a TiO2/ZnO composite film is synthesized by surface modification with TiO2 via sol-gel methods. Results show the anatase TiO2/ZnO nanorod composite film with a sharp, pencil-like structure exhibiting excellent superhydrophobicity (water contact angle of 155°), non-sticking water properties, and an autonomous cleaning property under UV irradiation. The anatase TiO2/ZnO nanorod composite film facilitates the precise measurement and extended lifetime of the QCM for the detection of organic gas molecules.
Konegger-Kappel, Stefanie; Prohaska, Thomas
2016-01-01
Laser ablation-multi-collector-inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) was optimized and investigated with respect to its performance for determining spatially resolved Pu isotopic signatures within radioactive fuel particle clusters. Fuel particles had been emitted from the Chernobyl nuclear power plant (ChNPP) where the 1986 accident occurred and were deposited in the surrounding soil, where weathering processes caused their transformation into radioactive clusters, so-called micro-samples. The size of the investigated micro-samples, which showed surface alpha activities below 40 mBq, ranged from about 200 to 1000 μm. Direct single static point ablations allowed to identify variations of Pu isotopic signatures not only between distinct fuel particle clusters but also within individual clusters. The resolution was limited to 100 to 120 μm as a result of the applied laser ablation spot sizes and the resolving power of the nuclear track radiography methodology that was applied for particle pre-selection. The determined (242)Pu/(239)Pu and (240)Pu/(239)Pu isotope ratios showed a variation from low to high Pu isotope ratios, ranging from 0.007(2) to 0.047(8) for (242)Pu/(239)Pu and from 0.183(13) to 0.577(40) for (240)Pu/(239)Pu. In contrast to other studies, the applied methodology allowed for the first time to display the Pu isotopic distribution in the Chernobyl fallout, which reflects the differences in the spent fuel composition over the reactor core. The measured Pu isotopic signatures are in good agreement with the expected Pu isotopic composition distribution that is typical for a RBMK-1000 reactor, indicating that the analyzed samples are originating from the ill-fated Chernobyl reactor. The average Pu isotope ratios [(240)Pu/(239)Pu = 0.388(86), (242)Pu/(239)Pu = 0.028(11)] that were calculated from all investigated samples (n = 48) correspond well to previously published results of Pu analyses in contaminated samples from the vicinity of the Chernobyl NPP [e.g. (240)Pu/(239)Pu = 0.394(2) and (242)Pu/(239)Pu = 0.027(1); Nunnemann et al. (J Alloys Compd 271-273:45-48, 1998)].
Xu, Xin-Xin; Cui, Zhong-Ping; Qi, Ji; Liu, Xiao-Xia
2013-03-21
To improve the photocatalytic activity of a coordination polymer in the visible light region, polyaniline (PANI) was loaded onto its surface through a facile in situ chemical oxidation polymerization process. The resulting PANI loaded coordination polymer composite materials with excellent stability exhibit significantly higher photocatalytic activities than the pure coordination polymer photocatalyst on the degradation of methyl orange (MO) under visible light irradiation. This enhancement can be ascribed to the introduction of PANI on the surface of the coordination polymer, which leads to efficient separation of photogenerated electron-hole pairs as well as a significant expansion of the photoresponse region. Finally, we discussed the influence of acidity on the morphology and photocatalytic activity of the composite material. An optimal condition to obtain the PANI loaded coordination polymer composite material with excellent photocatalytic activity has been obtained.
Novel matrix resins for composites for aircraft primary structures, phase 1
NASA Technical Reports Server (NTRS)
Woo, Edmund P.; Puckett, P. M.; Maynard, S.; Bishop, M. T.; Bruza, K. J.; Godschalx, J. P.; Mullins, M. J.
1992-01-01
The objective of the contract is the development of matrix resins with improved processability and properties for composites for primarily aircraft structures. To this end, several resins/systems were identified for subsonic and supersonic applications. For subsonic aircraft, a series of epoxy resins suitable for RTM and powder prepreg was shown to give composites with about 40 ksi compressive strength after impact (CAI) and 200 F/wet mechanical performance. For supersonic applications, a thermoplastic toughened cyanate prepreg system has demonstrated excellent resistance to heat aging at 360 F for 4000 hours, 40 ksi CAI and useful mechanical properties at greater than or equal to 310 F. An AB-BCB-maleimide resin was identified as a leading candidate for the HSCT. Composite panels fabricated by RTM show CAI of approximately 50 ksi, 350 F/wet performance and excellent retention of mechanical properties after aging at 400 F for 4000 hours.
Multi-Functional BN-BN Composite
NASA Technical Reports Server (NTRS)
Kang, Jin Ho (Inventor); Bryant, Robert G. (Inventor); Park, Cheol (Inventor); Sauti, Godfrey (Inventor); Gibbons, Luke (Inventor); Lowther, Sharon (Inventor); Thibeault, Sheila A. (Inventor); Fay, Catharine C. (Inventor)
2017-01-01
Multifunctional Boron Nitride nanotube-Boron Nitride (BN-BN) nanocomposites for energy transducers, thermal conductors, anti-penetrator/wear resistance coatings, and radiation hardened materials for harsh environments. An all boron-nitride structured BN-BN composite is synthesized. A boron nitride containing precursor is synthesized, then mixed with boron nitride nanotubes (BNNTs) to produce a composite solution which is used to make green bodies of different forms including, for example, fibers, mats, films, and plates. The green bodies are pyrolized to facilitate transformation into BN-BN composite ceramics. The pyrolysis temperature, pressure, atmosphere and time are controlled to produce a desired BN crystalline structure. The wholly BN structured materials exhibit excellent thermal stability, high thermal conductivity, piezoelectricity as well as enhanced toughness, hardness, and radiation shielding properties. By substituting with other elements into the original structure of the nanotubes and/or matrix, new nanocomposites (i.e., BCN, BCSiN ceramics) which possess excellent hardness, tailored photonic bandgap and photoluminescence, result.
NASA Astrophysics Data System (ADS)
Singh, Akanksha; Das, Sonatan; Bharathkumar, Mareddi; Revanth, D.; Karthik, ARB; Sudhakara Sastry, Bala; Ramgopal Rao, V.
2016-07-01
Flexible piezoelectric composites offer alternative and/or additional solutions to sensor, actuator and transducer applications. Here in this work, we have successfully fabricated highly flexible piezoelectric composites with poly dimethyl siloxane (PDMS) using herbal zinc oxide (h-ZnO) as filler having weight fractions up to 50 wt.% by solution casting of dispersions of h-ZnO in PDMS. Excellent piezo properties (Resonant frequency 935 Hz, d*33 29.76 pm V-1), physiochemical properties (Wurtzite structure ZnO, 380 nm absorbance) and mechanical properties (Young modulus 16.9 MPa) have been optimized with theoretical simulations and observed experimentally for h-ZnO + PDMS. As such, the demonstrated piezoelectric PDMS membranes combined with the excellent properties of these composites open new ways to ‘soft touch’ applications and could serve as a variety of soft and sensitive electromechanical transducers, which are desired for a variety of sensor and energy harvesting applications.
NASA Astrophysics Data System (ADS)
Zhang, Zhizhen; Xu, Kaiqi; Rong, Xiaohui; Hu, Yong-Sheng; Li, Hong; Huang, Xuejie; Chen, Liquan
2017-12-01
Solid electrolytes with high ionic conductivity and excellent electrochemical stability are of prime significance to enable the application of solid-state batteries in energy storage and conversion. In this study, solid composite polymer electrolytes (CPEs) based on sodium bis(trifluorosulfonyl) imide (NaTFSI) and poly (ethylene oxide) (PEO) incorporated with active ceramic filler (NASICON) are reported for the first time. With the addition of NASICON fillers, the thermal stability and electrochemical stability of the CPEs are improved. A high conductivity of 2.8 mS/cm (at 80 °C) is readily achieved when the content of the NASICON filler in the composite polymer reaches 50 wt%. Furthermore, Na3V2(PO4)3/CPE/Na solid-state batteries using this composite electrolyte display good rate and excellent cycle performance.
NASA Astrophysics Data System (ADS)
M. Amaral, Marcello; Raele, Marcus P.; Z. de Freitas, Anderson; Zahn, Guilherme S.; Samad, Ricardo E.; D. Vieira, Nilson, Jr.; G. Tarelho, Luiz V.
2009-07-01
This work presents a compositional characterization of 1939's Thousand "Réis" and 1945's One "Cruzeiro" Brazilian coins, forged on aluminum bronze alloy. The coins were irradiated by a Q-switched Nd:YAG laser with 4 ns pulse width and energy of 25mJ emitting at 1064nm reaching 3.1010Wcm-2 (assured condition for stoichiometric ablation), forming a plasma in a small fraction of the coin. Plasma emission was collected by an optical fiber system connected to an Echelle spectrometer. The capability of LIBS to remove small fraction of material was exploited and the coins were analyzed ablating layer by layer from patina to the bulk. The experimental conditions to assure reproductivity were determined by evaluation of three plasma paramethers: ionization temperature using Saha-Boltzmann plot, excitation temperature using Boltzmann plot, plasma density using Saha-Boltzmann plot and Stark broadening. The Calibration-Free LIBS technique was applied to both coins and the analytical determination of elemental composition was employed. In order to confirm the Edict Law elemental composition the results were corroborated by Neutron Activation Analysis (NAA). In both cases the results determined by CF-LIBS agreed to with the Edict Law and NAA determination. Besides the major components for the bronze alloy some other impurities were observed. Finally, in order to determine the coin damage made by the laser, the OCT (Optical Coherence Tomography) technique was used. After tree pulses of laser 54μg of coin material were removed reaching 120μm in depth.
Selective Disparity of Ordinary Chondritic Precursors in Micrometeorite Flux
NASA Astrophysics Data System (ADS)
Rudraswami, N. G.; Fernandes, D.; Naik, A. K.; Shyam Prasad, M.; Carrillo-Sánchez, J. D.; Plane, J. M. C.; Feng, W.; Taylor, S.
2018-01-01
All known extraterrestrial dust (micrometeoroids) entering the Earth’s atmosphere is anticipated to have a significant contribution from ordinary chondritic precursors, as seen in meteorites, but this is an apparent contradiction that needs to be addressed. Ordinary chondrites represent a minor contribution to the overall meteor influx compared to carbonaceous chondrites, which are largely dominated by CI and/or CM chondrites. However, the near-Earth asteroid population presents a scenario with sufficient scope for generation of dust-sized debris from ordinary chondritic sources. The bulk chemical composition of 3255 micrometeorites (MMs) collected from Antarctica and deep-sea sediments has shown Mg/Si largely dominated by carbonaceous chondrites, and less than 10% having ordinary chondritic precursors. The chemical ablation model is combined with different initial chondritic compositions (CI, CV, L, LL, H), and the results clearly indicate that high-density (≥2.8 g cm‑3) precursors, such as CV and ordinary chondrites in the size range 100–700 μm and zenith angle 0°–70°, ablate at much faster rates and lose their identity even before reaching the Earth’s surface and hence are under-represented in our collections. Moreover, their ability to survive as MMs remains grim for high-velocity micrometeoroids (>16 km s‑1). The elemental ratio for CV and ordinary chondrites are also similar to each other irrespective of the difference in the initial chemical composition. In conclusion, MMs belonging to ordinary chondritic precursors’ concentrations may not be insignificant in thermosphere, as they are found on Earth’s surface.
USDA-ARS?s Scientific Manuscript database
Extruded/injection-molded composites were produced from plantain flour blended with ethylene vinyl-alcohol (EVA) and glycerol. Scanning electron microscopy showed composites had a smooth surface and excellent compatibility between plantain flour, EVA and glycerol. The impact of increased plantain fl...
Zhu, Jie; Huo, Xiaohe; Liu, Xiaoqiang; Ju, Huangxian
2016-01-13
A novel ternary composite composed of TiO2 nanotubes (TiONTs), polyaniline (PANI), and gold nanoparticles (GNPs) was prepared for photoelectrochemical (PEC) biosensing. PANI was initially coated on TiONTs with an oxidative polymerization method, and 12-phosphotungstic acid was then used as a highly localized photoactive reducing agent to deposit GNPs on TiONT-PANI. The morphology and composition of the composite were characterized by various spectroscopic and microscopic methods. Electrochemical impedance spectroscopy was also conducted to demonstrate the excellent electrical conductivity of the composite. A PEC biosensor was fabricated by immobilizing a mixture of lactate dehydrogenase and the composite onto ITO electrodes, which regenerated nicotinamide adenine dinucleotide (NAD(+)) to complete the enzymatic cycle and led to an improved method for PEC detection of lactate. Because of the surface plasmon resonance enhanced effect of GNPs, the electrochromic performance of PANI, and excellent conductivity and biocompatibility of the composite, this method showed a dynamic range of 0.5-210 μM, sensitivity of 0.0401 μA μM(-1), and a detection limit of 0.15 μM.
Malignant conversion of a solitary papilloma in the distal trachea: Report of a case
Lioulias, Achilleas; Misthos, Panagiotis; Papagiannakis, Georgios; Mermigkis, Dimitrios; Karagianidis, Napoleon; Neofotistos, Kostas; Kokotsakis, John
2008-01-01
A solitary papilloma versus the usual multiple lesions of papillomatosis is extremely rare. Even more infrequent is a solitary papilloma of the trachea in an adult patient. In the present report, a case of a solitary papilloma in the distal trachea is presented. After two unsuccessful sessions of laser ablation, resection of the lower one-third of the trachea was performed through a right posterolateral thoracotomy. Postoperative histology results disclosed a malignant degeneration into squamous cell carcinoma. The patient had an excellent outcome after resection of the affected portion of the trachea. There was no evidence of recurrence after 20 months of follow-up. PMID:18949108
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ren, Xiaoying; Hu, Zhongai, E-mail: zhongai@nwnu.edu.cn; Hu, Haixiong
2015-10-15
Graphical abstract: Electroactive methyl green (MG) is selected to functionalize reduced graphene oxide (RGO) through non-covalent modification and the composite achieves high specific capacitance, good rate capability and excellent long life cycle. - Highlights: • MG–RGO composites were firstly prepared through non-covalent modification. • The mass ratio in composites is a key for achieving high specific capacitance. • MG–RGO 5:4 exhibits the highest specific capacitance of 341 F g{sup −1}. • MG–RGO 5:4 shows excellent rate capability and long life cycle. - Abstract: In the present work, water-soluble electroactive methyl green (MG) has been used to non-covalently functionalize reduced graphenemore » oxide (RGO) for enhancing supercapacitive performance. The microstructure, composition and morphology of MG–RGO composites are systematically characterized by UV–vis absorption, field emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM) and X-ray diffraction (XRD). The electrochemical performances are investigated by cyclic voltammetry (CV), galvanostatic charge/discharge and electrochemical impedance spectroscopy (EIS). The fast redox reactions from MG could generate additional pseudocapacitance, which endows RGO higher capacitances. As a result, the MG–RGO composite (with the 5:4 mass ratio of MG:RGO) achieve a maximum value of 341 F g{sup −1} at 1 A g{sup −1} within the potential range from −0.25 to 0.75 V and provide a 180% enhancement in specific capacitance in comparison with pure RGO. Furthermore, excellent rate capability (72% capacitance retention from 1 A g{sup −1} to 20 A g{sup −1}) and long life cycle (12% capacitance decay after 5000 cycles) are achieved for the MG–RGO composite electrode.« less
NASA Astrophysics Data System (ADS)
Wang, Huan; Qiu, Xueqing; Liu, Weifeng; Yang, Dongjie
2017-12-01
In this work, a novel lignin-based carbon/ZnO (LC/ZnO) hybrid composite with excellent photocatalytic performance was prepared through a convenient and environment friendly method using alkali lignin (AL) as carbon source. The morphological, microstructure and optical properties of the as-prepared LC/ZnO hybrid composite was characterized with scanning electron microscope (SEM), X-ray diffraction (XRD), Raman and UV-vis. The resulting LC/ZnO hybrid is composed of highly dispersed ZnO nanoparticles embedded on a lignin-based carbon nanosheet, showing excellent photogenerated electrons and holes separation and migration efficiency. The photocatalytic activity of LC/ZnO was much higher than the pure ZnO. The LC/ZnO hybrid composite showed different photocatalytic mechanism for degradation of negative methyl orange (MO) and positive Rhodamine B (RhB). It showed that h+ was the main photocatalytic active group during the degradation of MO, ·O2- and ·OH were the photocatalytic active groups during degradation of RhB. This reported photocatalyst with selective degradation of positive and negative organic dyes may have a great application prospect for photoelectric conversion and catalytic materials. Results of this work were of practical importance for high-valued utilization of lignin for carbon materials.
Ranjan, Ravi; McGann, Christopher J.; Jeong, Eun-Kee; Hong, KyungPyo; Kholmovski, Eugene G.; Blauer, Josh; Wilson, Brent D.; Marrouche, Nassir F.; Kim, Daniel
2015-01-01
Aim Late gadolinium enhanced (LGE) magnetic resonance imaging (MRI) is a useful tool for facilitating ventricular tachycardia (VT) ablation. Unfortunately, most VT ablation candidates often have prophylactic implantable cardioverter-defibrillator (ICD) and do not undergo cardiac MRI largely due to image artefacts generated by ICD. A prior study has reported success of ‘wideband’ LGE MRI for imaging myocardial scar without image artefacts induced by ICD at 1.5T. The purpose of this study was to widen the availability of wideband LGE MRI to 3T, since it has the potential to achieve higher spatial resolution than 1.5T. Methods and results We compared the performance of standard and wideband LGE MRI pulse sequences in phantoms and canines with myocardial lesions created by radiofrequency ablation. Standard LGE MRI produced image artefacts induced by ICD and 49% accuracy in detecting 97 myocardial scars examined in this study, whereas wideband LGE MRI produced artefact-free images and 94% accuracy in detecting scars. The mean image quality score (1 = nondiagnostic, 2 = poor, 3 = adequate, 4 = good, 5 = excellent) was significantly (P < 0.001) higher for wideband (3.7 ± 0.8) than for standard LGE MRI (2.1 ± 0.7). The mean artefact level score (1 = minimal, 2 = mild, 3 = moderate, 4 = severe, 5 = nondiagnostic) was significantly (P < 0.001) lower for wideband (2.1 ± 0.8) than for standard LGE MRI (4.0 ± 0.6). Wideband LGE MRI agreed better with gross pathology than standard LGE MRI. Conclusion This study demonstrates the feasibility of wideband LGE MRI for suppression of image artefacts induced by ICD at 3T. PMID:25336666
Padeletti, Luigi; Curnis, Antonio; Tondo, Claudio; Lunati, Maurizio; Porcellini, Stefano; Verlato, Roberto; Sciarra, Luigi; Senatore, Gaetano; Catanzariti, Domenico; Leoni, Loira; Landolina, Maurizio; Delise, Pietro; Iacopino, Saverio; Pieragnoli, Paolo; Arena, Giuseppe
2017-01-01
Catheter ablation (CA) is recommended for patients with drug refractory symptomatic atrial fibrillation (AF). "One Shot" catheters have been introduced to simplify CA and cryoballoon ablation (CBA) is spreading rapidly. Few real-world data are available on standard clinical practice, mainly from single-center experience. We aimed to evaluate clinical settings, demographics, and acute procedural outcomes in a large cohort of patients treated with CBA. A total of 903 patients (73% male, mean age 59 ± 11) underwent pulmonary vein CBA. Correlations between the patient's inclusion time and clinical characteristics, procedure duration, acute success rate, and intraprocedural complications were evaluated. Seventy-seven percent of patients were affected by paroxysmal AF and 23% by persistent AF. Overall, acute success rate was 97.9% and periprocedural complications were observed in 35 (3.9%) patients, 13 (1.4%) of which were classified as major complications. With respect to the patient's inclusion time analysis, an increase in treatment of persistent AF was observed, a significant decrease in CBA times (procedure, ablation, and fluoroscopy: 136.0 ± 46.5 minutes, 28.8 ± 19.6 minutes, and 34.3 ± 15.4 minutes, respectively) was observed, with comparable acute success rate and intraprocedural complications over time. The rate of major complications was extremely low (1.4%); no death, atrioesophageal fistula, stroke, or other major periinterventional or late complications occurred. This series represents the largest experience of CBA in the treatment of AF that also describes the adoption curve of this relatively recent technology. CBA showed an excellent safety profile when performed in a large real-world clinical setting, with satisfactory acute success rate and, on average, short procedural times. clinicaltrials.gov (NCT01007474). © 2016 Wiley Periodicals, Inc.
Shokrollahi, Parvin; Mirzadeh, Hamid; Scherman, Oren A; Huck, Wilhelm T S
2010-10-01
Supramolecular polymers based on quadruple hydrogen-bonding ureido-pyrimidinone (UPy) moieties hold promise as dynamic/stimuli-responsive materials in applications such as tissue engineering. Here, a new class of materials is introduced: supramolecular polymer composites. We show that despite the highly ordered structure and tacticity-dependent nature of hydrogen-bonded supramolecular polymers, the bioactivity of these polymers can be tuned through composite preparation with bioceramics. These novel supramolecular composites combine the superior processability of supramolecular polymers with the excellent bioactivity and mechanical characteristics of bioceramics. In particular, the bioactive composites prepared from supramolecular polycaprolactone and UPy-grafted hydroxyapatite (HApUPy) are described that can be easily formed into microporous biomaterials. The compression moduli increased about 40 and 90% upon composite preparation with HAp and HApUPy, respectively, as an indication to improved mechanical properties. These new materials show excellent potential as microporous composite scaffolds for the adhesion and proliferation of rat mesenchymal stem cells (rMSCs) as a first step toward bone regeneration studies; rMSCs proliferate about 2 and 2.7 times faster on the conventional composite with HAp and the supramolecular composite with (HApUPy) than on the neat PCL1250(UPy)(2). Copyright 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2010.
Examination of Chemical Approaches to Stabilizing Composite Propellant Combustion
1991-10-15
improve survivability (by reducing detectability ) of the missiles and their launch platforms, e.g., aircraft. This requirement precludes inclusion of...EOXIDIZER - EFUEL 2000 6- EOXlDIZER - EFUEL = 1000 4 - EO I EFEIJEL =0 , 2 0 10 20 30 40 50 60 70 803 DIMENSIONLESS OSCILLATION FREOUENCY, cop I I I I I...ablation charac- teristics would involve occlusion of possible catalysts in the oxidizer crystals or co-crystallization of mixed oxidizers (such as
Valinoti, Maddalena; Fabbri, Claudio; Turco, Dario; Mantovan, Roberto; Pasini, Antonio; Corsi, Cristiana
2018-01-01
Radiofrequency ablation (RFA) is an important and promising therapy for atrial fibrillation (AF) patients. Optimization of patient selection and the availability of an accurate anatomical guide could improve RFA success rate. In this study we propose a unified, fully automated approach to build a 3D patient-specific left atrium (LA) model including pulmonary veins (PVs) in order to provide an accurate anatomical guide during RFA and without PVs in order to characterize LA volumetry and support patient selection for AF ablation. Magnetic resonance data from twenty-six patients referred for AF RFA were processed applying an edge-based level set approach guided by a phase-based edge detector to obtain the 3D LA model with PVs. An automated technique based on the shape diameter function was designed and applied to remove PVs and compute LA volume. 3D LA models were qualitatively compared with 3D LA surfaces acquired during the ablation procedure. An expert radiologist manually traced the LA on MR images twice. LA surfaces from the automatic approach and manual tracing were compared by mean surface-to-surface distance. In addition, LA volumes were compared with volumes from manual segmentation by linear and Bland-Altman analyses. Qualitative comparison of 3D LA models showed several inaccuracies, in particular PVs reconstruction was not accurate and left atrial appendage was missing in the model obtained during RFA procedure. LA surfaces were very similar (mean surface-to-surface distance: 2.3±0.7mm). LA volumes were in excellent agreement (y=1.03x-1.4, r=0.99, bias=-1.37ml (-1.43%) SD=2.16ml (2.3%), mean percentage difference=1.3%±2.1%). Results showed the proposed 3D patient-specific LA model with PVs is able to better describe LA anatomy compared to models derived from the navigation system, thus potentially improving electrograms and voltage information location and reducing fluoroscopic time during RFA. Quantitative assessment of LA volume derived from our 3D LA model without PVs is also accurate and may provide important information for patient selection for RFA. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Liang, Liying; Xu, Yimeng; Lei, Yong; Liu, Haimei
2014-03-01
Three-dimensional (3D) porous composite aerogels have been synthesized via an innovative in situ hydrothermal method assisted by a freeze-drying process. In this hybrid structure, one-dimensional (1D) AgVO3 nanowires are uniformly dispersed on two-dimensional (2D) graphene nanosheet surfaces and/or are penetrated through the graphene sheets, forming 3D porous composite aerogels. As cathode materials for lithium-ion batteries, the composite aerogels exhibit high discharge capacity, excellent rate capability, and good cycling stability.Three-dimensional (3D) porous composite aerogels have been synthesized via an innovative in situ hydrothermal method assisted by a freeze-drying process. In this hybrid structure, one-dimensional (1D) AgVO3 nanowires are uniformly dispersed on two-dimensional (2D) graphene nanosheet surfaces and/or are penetrated through the graphene sheets, forming 3D porous composite aerogels. As cathode materials for lithium-ion batteries, the composite aerogels exhibit high discharge capacity, excellent rate capability, and good cycling stability. Electronic supplementary information (ESI) available: Preparation, characterization, SEM images, XRD patterns, and XPS of AgVO3/GAs. See DOI: 10.1039/c3nr06899d
Magnetic CuHCNPAN nano composite as an efficient adsorbent for strontium uptake
NASA Astrophysics Data System (ADS)
Mobtaker, Hossein Ghasemi; Pakzad, Seyed Mohammadreza; Yousefi, Taher
2018-06-01
An excellent composite was synthesized for sorption of strontium from solution. The composite (CuHCNPAN) components were copper hexacyanoferrate, magnetite and PAN. The XRD method confirmed the formation and presence of two crystalline phases of magnetite and copper hexacyanoferrate in composite. Particle sizes were determined by XRD and SEM methods. It was found that the particles were nano size. Some other methods such as FT IR, BET and TG methods were also used to determine the properties of the composite. The composite was used for sorption of strontium from solution. It was found that the kinetic of strontium sorption by the composite could be modeled by pseudo-second order. Among the isotherms applied to modeling the sorption in various concentrations, the Langmuir isotherm was founded to be more appropriate to fitting the experimental data. An excellent correlation coefficient was obtained (R2 > 0.98). The qmax for sorption of strontium ions which was calculated by Langmuir model was 80 mg/g. The thermodynamic parameters were calculated by determination of sorption in various temperatures and using the Vant Hoff plot. ΔG°, ΔH°, and ΔS° were calculated as -19.15, 2.28 and 0.071 kJ/mol respectively.
Jowett, Nathan; Hadlock, Tessa A; Sela, Eyal; Toth, Miklos; Knecht, Rainald; Lörincz, Balazs B
2017-04-01
To objectively assess donor site morbidity after harvesting the facial artery musculomucosal flap. Use of the FAMM-flap in oral cavity reconstruction remains sporadic. This case series describes our newly developed standardized assessment of this flap in a floor of mouth (FOM) reconstructive setting. Standardized postoperative assessment of the FAMM flap for donor site wound complications, functional, facial mimetic and oncologic outcomes. There were no wound complications. Oral competence remained intact, tongue mobility was good to excellent, average word articulation score was 98%, and mimetic function excellent in all patients. Three patients experienced ipsilateral upper lip anesthesia, and five patients were noted to have slight dysfunction of the orbicularis oris resulting in a loss of lip height at rest. The FAMM flap is a reliable option for reconstruction of ablative defects of the FOM, and should be considered a workhorse flap for oral cavity defects. Unlike the submental island flap, a complete level I dissection may be concurrently performed without compromising the vascular supply to the FAMM flap. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhang, Zhipeng; von Wenckstern, Holger; Lenzner, Jörg; Grundmann, Marius
2016-06-01
We report on ultraviolet photodiodes with integrated optical filter based on the wurtzite (Mg,Zn)O thin films. Tuning of the bandgap of filter and active layers was realized by employing a continuous composition spread approach relying on the ablation of a single segmented target in pulsed-laser deposition. Filter and active layers of the device were deposited on opposite sides of a sapphire substrate with nearly parallel compositional gradients. Ensure that for each sample position the bandgap of the filter layer blocking the high energy radiation is higher than that of the active layer. Different oxygen pressures during the two depositions runs. The absorption edge is tuned over 360 meV and the spectral bandwidth of photodiodes is typically 100 meV and as low as 50 meV.
NASA Astrophysics Data System (ADS)
Mao, J. W.; He, C. H.; Qi, J. Q.; Zhang, A. B.; Sui, Y. W.; He, Y. Z.; Meng, Q. K.; Wei, F. X.
2018-01-01
In the present work, mesoporous NiCo2O4 nanorod/graphene oxide (NiCo2O4/GO) composite was prepared by a facile and cost-effective hydrothermal method and meanwhile, N-doped graphene (N-G) was fabricated also by a hydrothermal synthesis process. NiCo2O4/GO composite and N-G were used as positive and negative electrodes for the supercapacitor, respectively, which all displayed excellent electrochemical performances. The NiCo2O4/GO composite electrode exhibited a high specific capacitance of 709.7 F g-1 at a current density of 1 A g-1 and excellent rate capability as well as good cycling performance with 84.7% capacitance retention at 6 A g-1 after 3000 cycles. A high-voltage asymmetric supercapacitor (ASC) was successfully fabricated using NiCo2O4/GO composite and N-G as the positive and negative electrodes, respectively, in 1 M KOH aqueous electrolyte. The ASC delivered a high energy density of 34.4 Wh kg-1 at a power density of 800 W kg-1 and still maintained 28 Wh kg-1 at a power density of 8000 W kg-1. Furthermore, this ASC showed excellent cycling stability with 94.3% specific capacitance retained at 5 A g-1 after 5000 cycles. The impressive results can be ascribed to the positive synergistic effects of the two electrodes. Evidently, our work provides useful information for assembling high-performance supercapacitor devices.
NASA Astrophysics Data System (ADS)
Li, Jiang; Guo, Meng-fei; Lv, Xiang; Liu, Yang; Xi, Kun; Guan, Yi-wen
2018-04-01
In this study, a dense particles erosion test motor which can simulate the erosion state of a solid rocket motor under high acceleration was developed. Subsequently, erosion experiments were carried out for the ethylene propylene diene monomer composite insulation and the microstructure of the char layer analysed. A turning point effect was found from the influence of the particle impact velocity on the ablation rate, and three erosion modes were determined according to the micro-morphology of the char layer. A reasonable explanation for the different structures of the char layer in the three modes was presented based on the formation mechanism of the compact/loose structure of the char layer.
A hydrodynamic mechanism of meteor ablation. The melt-spraying model
NASA Astrophysics Data System (ADS)
Girin, Oleksandr G.
2017-10-01
Context. Hydrodynamic conditions are similar in a molten meteoroid and a liquid drop in a high-speed airflow. Despite the fact that the latter is well-studied, both experimentally and theoretically, hydrodynamic instability theory has not been applied to study the fragmentation of molten meteoroids. Aims: We aim to treat quasi-continuous spraying of meteoroid melt due to hydrodynamic instability as a possible mechanism of ablation. Our objectives are to calculate the time development of particle release, the released particle sizes and their distribution by sizes, as well as the meteoroid mass loss law. Methods: We have applied gradient instability theory to model the behaviour of the meteoroid melt layer and its interaction with the atmosphere. We have assumed a spherical meteoroid and that the meteoroid has a shallow entry angle, such that the density of the air stream interacting with the meteoroid is nearly constant. Results: High-frequency spraying of the molten meteoroid is numerically simulated. The intermediate and final size distributions of released particles are calculated, as well as the meteoroid mass loss law. Fast and slow meteoroids of iron and stone compositions are modelled, resulting in significant differences in the size distribution of melt particles sprayed from each meteoroid. Less viscous iron melt produces finer particles and a denser aerosol wake than a stony one does. Conclusions: Analysis of the critical conditions for the gradient instability mechanism shows that the dynamic pressure of the air-stream at heights up to 100 km is sufficient to overcome surface tension forces and pull out liquid particles from the meteoroid melt by means of unstable disturbances. Hence, the proposed melt-spraying model is able to explain quasi-continuous mode of meteoroid fragmentation at large heights and low dynamic pressures. A closed-form solution of the meteoroid ablation problem is obtained due to the melt-spraying model usage, at the meteoroid composition, initial radius and velocity being given. The movies associated to Figs. 6 and 7 are available at http://www.aanda.org
Martin, Gregory G; Atshaves, Barbara P; Landrock, Kerstin K; Landrock, Danilo; Storey, Stephen M; Howles, Philip N; Kier, Ann B; Schroeder, Friedhelm
2014-12-01
On the basis of their abilities to bind bile acids and/or cholesterol, the physiological role(s) of liver fatty acid-binding protein (L-FABP) and sterol carrier protein (SCP) 2/SCP-x (SCP-2/SCP-x) gene products in biliary bile acid and cholesterol formation was examined in gene-ablated male mice. L-FABP (LKO) or L-FABP/SCP-2/SCP-x [triple-knockout (TKO)] ablation markedly decreased hepatic bile acid concentration, while SCP-2/SCP-x [double-knockout (DKO)] ablation alone had no effect. In contrast, LKO increased biliary bile acid, while DKO and TKO had no effect on biliary bile acid levels. LKO and DKO also altered biliary bile acid composition to increase bile acid hydrophobicity. Furthermore, LKO and TKO decreased hepatic uptake and biliary secretion of high-density lipoprotein (HDL)-derived 22-(N-(7-nitrobenz-2-oxa-1,3-diazol-4-yl)amino)-23,24-bisnor-5-cholen-3β-ol (NBD-cholesterol), while DKO alone had no effect. Finally, LKO and, to a lesser extent, DKO decreased most indexes contributing to cholesterol solubility in biliary bile. These results suggest different, but complementary, roles for L-FABP and SCP-2/SCP-x in biliary bile acid and cholesterol formation. L-FABP appears to function more in hepatic retention of bile acids as well as hepatic uptake and biliary secretion of HDL-cholesterol. Conversely, SCP-2/SCP-x may function more in formation and biliary secretion of bile acid, with less impact on hepatic uptake or biliary secretion of HDL-cholesterol. Copyright © 2014 the American Physiological Society.
Formation of Plasma Around a Small Meteoroid: Simulation and Theory
NASA Astrophysics Data System (ADS)
Sugar, G.; Oppenheim, M. M.; Dimant, Y. S.; Close, S.
2018-05-01
High-power large-aperture radars detect meteors by reflecting radio waves off dense plasma that surrounds a hypersonic meteoroid as it ablates in the Earth's atmosphere. If the plasma density profile around the meteoroid is known, the plasma's radar cross section can be used to estimate meteoroid properties such as mass, density, and composition. This paper presents head echo plasma density distributions obtained via two numerical simulations of a small ablating meteoroid and compares the results to an analytical solution found in Dimant and Oppenheim (2017a, https://doi.org/10.1002/2017JA023960, 2017b, https://doi.org/10.1002/2017JA023963). The first simulation allows ablated meteoroid particles to experience only a single collision to match an assumption in the analytical solution, while the second is a more realistic simulation by allowing multiple collisions. The simulation and analytical results exhibit similar plasma density distributions. At distances much less than λT, the average distance an ablated particle travels from the meteoroid before a collision with an atmospheric particle, the plasma density falls off as 1/R, where R is the distance from the meteoroid center. At distances substantially greater than λT, the plasma density profile has an angular dependence, falling off as 1/R2 directly behind the meteoroid, 1/R3 in a plane perpendicular to the meteoroid's path that contains the meteoroid center, and exp[-1.5(R/λT2/3)]/R in front of the meteoroid. When used for calculating meteoroid masses, this new plasma density model can give masses that are orders of magnitude different than masses calculated from a spherically symmetric Gaussian distribution, which has been used to calculate masses in the past.
Kawamura, Mitsuharu; Scheinman, Melvin M; Tseng, Zian H; Lee, Byron K; Marcus, Gregory M; Badhwar, Nitish
2017-01-01
Catheter ablation for idiopathic ventricular arrhythmia (VA) is effective and safe, but efficacy is frequently limited due to an epicardial origin and difficult anatomy. The remote magnetic navigation (RMN) catheter has a flexible catheter design allowing access to difficult anatomy. We describe the efficacy of the RMN for ablation of idiopathic VA after failed manual ablation. Among 235 patients with idiopathic VA referred for catheter ablation, we identified 51 patients who were referred for repeat ablation after a failed manual ablation. We analyzed the clinical characteristics, including the successful ablation site and findings at electrophysiology study, in repeat procedures conducted using RMN as compared with manual ablation. Among these patients, 22 (43 %) underwent repeat ablation with the RMN and 29 (57 %) underwent repeat ablation with a manual ablation. Overall, successful ablation rate was significantly higher using RMN as compared with manual ablation (91 vs. 69 %, P = 0.02). Fluoroscopy time in the RMN was 17 ± 12 min as compared with 43 ± 18 min in the manual ablation (P = 0.009). Successful ablation rate in the posterior right ventricular outflow tract (RVOT) plus posterior-tricuspid annulus was higher with RMN as compared with manual ablation (92 vs. 50 %, P = 0.03). Neither groups exhibited any major complications. The RMN is more effective in selected patients with recurrent idiopathic VA after failed manual ablation and is associated with less fluoroscopy time. The RMN catheters have a flexible design enabling them to access otherwise difficult anatomy including the posterior tricuspid annulus and posterior RVOT.
China Report, Economic Affairs.
1987-03-19
34Bring the Advantages of Grain To Bear and Promote Economic Development--A Preliminary Exploration of Measures To Readjust Agricultural Composition ...in cultivation may lay an excellent foundation for current rural reforms and readjustments in industrial composition , and it will ensure that the...in agricultural production throughout Jilin. Consequently, how we proceed from the actual situation in Jilin to readjust agricultural composition
Wu, Po-Hung; Brace, Chris L
2016-08-21
Intra-procedural contrast-enhanced CT (CECT) has been proposed to evaluate treatment efficacy of thermal ablation. We hypothesized that contrast material delivered concurrently with thermal ablation may become trapped in the ablation zone, and set out to determine whether such an effect would impact ablation visualization. CECT images were acquired during microwave ablation in normal porcine liver with: (A) normal blood perfusion and no iodinated contrast, (B) normal perfusion and iodinated contrast infusion or (C) no blood perfusion and residual iodinated contrast. Changes in CT attenuation were analyzed from before, during and after ablation to evaluate whether contrast was trapped inside of the ablation zone. Visualization was compared between groups using post-ablation contrast-to-noise ratio (CNR). Attenuation gradients were calculated at the ablation boundary and background to quantitate ablation conspicuity. In Group A, attenuation decreased during ablation due to thermal expansion of tissue water and water vaporization. The ablation zone was difficult to visualize (CNR = 1.57 ± 0.73, boundary gradient = 0.7 ± 0.4 HU mm(-1)), leading to ablation diameter underestimation compared to gross pathology. Group B ablations saw attenuation increase, suggesting that iodine was trapped inside the ablation zone. However, because the normally perfused liver increased even more, Group B ablations were more visible than Group A (CNR = 2.04 ± 0.84, boundary gradient = 6.3 ± 1.1 HU mm(-1)) and allowed accurate estimation of the ablation zone dimensions compared to gross pathology. Substantial water vaporization led to substantial attenuation changes in Group C, though the ablation zone boundary was not highly visible (boundary gradient = 3.9 ± 1.1 HU mm(-1)). Our results demonstrate that despite iodinated contrast being trapped in the ablation zone, ablation visibility was highest when contrast is delivered intra-procedurally. Therefore, CECT may be feasible for real-time thermal ablation monitoring.
Illustrating Consumer Theory with the CES Utility Function
ERIC Educational Resources Information Center
Tohamy, Soumaya M.; Mixon, J. Wilson, Jr.
2004-01-01
The authors use Microsoft Excel to derive compensated and uncompensated demand curves. They use a constant elasticity of substitution (CES) utility function to show how changes in a good's price or income affect the quantities demanded of that good and of the other composite good, using Excel's Solver. They provide three contributions. First, they…
NASA Astrophysics Data System (ADS)
Rabinovitch, Jason
Motivated by recent MSL results where the ablation rate of the PICA heatshield was over-predicted, and staying true to the objectives outlined in the NASA Space Technology Roadmaps and Priorities report, this work focuses on advancing EDL technologies for future space missions. Due to the difficulties in performing flight tests in the hypervelocity regime, a new ground testing facility called the vertical expansion tunnel is proposed. The adverse effects from secondary diaphragm rupture in an expansion tunnel may be reduced or eliminated by orienting the tunnel vertically, matching the test gas pressure and the accelerator gas pressure, and initially separating the test gas from the accelerator gas by density stratification. If some sacrifice of the reservoir conditions can be made, the VET can be utilized in hypervelocity ground testing, without the problems associated with secondary diaphragm rupture. The performance of different constraints for the Rate-Controlled Constrained-Equilibrium (RCCE) method is investigated in the context of modeling reacting flows characteristic to ground testing facilities, and re-entry conditions. The effectiveness of different constraints are isolated, and new constraints previously unmentioned in the literature are introduced. Three main benefits from the RCCE method were determined: 1) the reduction in number of equations that need to be solved to model a reacting flow; 2) the reduction in stiffness of the system of equations needed to be solved; and 3) the ability to tabulate chemical properties as a function of a constraint once, prior to running a simulation, along with the ability to use the same table for multiple simulations. Finally, published physical properties of PICA are compiled, and the composition of the pyrolysis gases that form at high temperatures internal to a heatshield is investigated. A necessary link between the composition of the solid resin, and the composition of the pyrolysis gases created is provided. This link, combined with a detailed investigation into a reacting pyrolysis gas mixture, allows a much needed consistent, and thorough description of many of the physical phenomena occurring in a PICA heatshield, and their implications, to be presented. Through the use of computational fluid mechanics and computational chemistry methods, significant contributions have been made to advancing ground testing facilities, computational methods for reacting flows, and ablation modeling.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bates, Robert; McConnell, Elizabeth
Machining methods across many industries generally require multiple operations to machine and process advanced materials, features with micron precision, and complex shapes. The resulting multiple machining platforms can significantly affect manufacturing cycle time and the precision of the final parts, with a resultant increase in cost and energy consumption. Ultrafast lasers represent a transformative and disruptive technology that removes material with micron precision and in a single step manufacturing process. Such precision results from athermal ablation without modification or damage to the remaining material which is the key differentiator between ultrafast laser technologies and traditional laser technologies or mechanical processes.more » Athermal ablation without modification or damage to the material eliminates post-processing or multiple manufacturing steps. Combined with the appropriate technology to control the motion of the work piece, ultrafast lasers are excellent candidates to provide breakthrough machining capability for difficult-to-machine materials. At the project onset in early 2012, the project team recognized that substantial effort was necessary to improve the application of ultrafast laser and precise motion control technologies (for micromachining difficult-to-machine materials) to further the aggregate throughput and yield improvements over conventional machining methods. The project described in this report advanced these leading-edge technologies thru the development and verification of two platforms: a hybrid enhanced laser chassis and a multi-application testbed.« less
Oshiro, Thomas; Sinha, Usha; Lu, David; Sinha, Shantanu
2002-01-01
MRI has been used increasingly in the recent past for the guidance and monitoring of minimally invasive interventional procedures, using typically radiofrequency (RF) and laser energy, cryoablation, and percutaneous ethanol. RF energy has been used over the last 30 years for the ablation of tissues. Its use in conjunction with MRI for monitoring is limited, however, because of the electronic noise produced by the RF generators, which can significantly deteriorate image quality. The objective of this work was to devise methods by which this noise can be reduced to an acceptable level to allow simultaneous acquisition of MR images for monitoring purposes with the application of RF energy. Three different methods of noise reduction were investigated in a 0.2 T MR scanner: filtration using external hardware circuitry, MR scanner software-controlled filtration, and keyholing. The last two methods were unable by themselves to suppress the noise to an acceptable degree. Hardware filtration, however, provides excellent suppression of RF noise and is able to withstand up to 12 W of RF energy. When all the three approaches are combined, significant reduction of RF noise is achieved. The feasibility of creating an RF lesion of about 1.2 cm diameter in vivo in a porcine model simultaneously with temperature-sensitive MRI with adequate noise suppression is demonstrated.
Schroeter, Thomas; Misfeld, Martin
2017-04-01
Atrial fibrillation has a significant impact on patient mortality and morbidity. In particular, stroke is a frequent complication associated with atrial fibrillation. In recent years, various treatment options have been developed that are based on the elimination of atypical electrically active atrial areas. Areas covered: This manuscript presents a new cryoablation probe from AtriCure Inc. In addition to describing the characteristics of the probe, we also discuss atrial fibrillation and its surgical therapy options as well as the basics of cryosurgery. The cryoFORM® cryoablation probe is an ablation system developed for cardiothoracic surgeons that utilizes nitrous oxide (N 2 O) to create continuous transmural lesions that block propagation of atrial activation. The main features of the probe are an excellent working capacity due to the use of N 2 O, high flexibility, and, in combination with the cryoICE® Box V6, an active defrost mode for quick detachment. Expert commentary: The cryoFORM® ablation probe is a new device for the treatment of atrial fibrillation using N 2 O as an energy source. The probe is made from stainless steel and has a corrugated surface, a design that provides a higher flexibility than the cryoICE probe.
NASA Astrophysics Data System (ADS)
Salomir, Rares
2005-09-01
Therapeutic ultrasound is a mini-invasive and promising tool for in situ ablation of non-resectable tumors in uterus, breast, esophagus, kidney, liver, etc. Extracorporeal, endoluminal, and interstitial applicators have been successfully tested to date. Magnetic resonance imaging (MRI) is the only available technique providing non-invasive temperature mapping, together with excellent contrast of soft tissue. Coupling of these two technologies offers the advantage of both: (1) on line spatial guidance to the target region, and (2) thermal dose control during the treatment. This talk will provide an overview of the author's experience with automatic, active feedback control of the temperature evolution in tissues, which has been demonstrated with MRI compatible extracorporeal transducers (focused beam) or endoluminal applicators (plane waves). The feedback loop is based on fast switching capabilities of the driving electronics and real time data transfer out of the MR scanner. Precision of temperature control was typically better than 1°C. This approach is expected to improve the efficacy of the treatment (complete tumor ablation) and the thermal security of the critical regions crossed by the acoustic beam. It also permits one to reach an under-lethal heating regime for local drug delivery using thermosensitive liposomes or gene expression control based on hsp promoters.
Duodu, Godfred Odame; Goonetilleke, Ashantha; Allen, Charlotte; Ayoko, Godwin A
2015-10-22
Wet-milling protocol was employed to produce pressed powder tablets with excellent cohesion and homogeneity suitable for laser ablation (LA) analysis of volatile and refractive elements in sediment. The influence of sample preparation on analytical performance was also investigated, including sample homogeneity, accuracy and limit of detection. Milling in volatile solvent for 40 min ensured sample is well mixed and could reasonably recover both volatile (Hg) and refractive (Zr) elements. With the exception of Cr (-52%) and Nb (+26%) major, minor and trace elements in STSD-1 and MESS-3 could be analysed within ±20% of the certified values. Comparison of the method with total digestion method using HF was tested by analysing 10 different sediment samples. The laser method recovers significantly higher amounts of analytes such as Ag, Cd, Sn and Sn than the total digestion method making it a more robust method for elements across the periodic table. LA-ICP-MS also eliminates the interferences from chemical reagents as well as the health and safety risks associated with digestion processes. Therefore, it can be considered as an enhanced method for the analysis of heterogeneous matrices such as river sediments. Copyright © 2015 Elsevier B.V. All rights reserved.
Multidimensional Tests of Thermal Protection Materials in the Arcjet Test Facility
NASA Technical Reports Server (NTRS)
Agrawal, Parul; Ellerby, Donald T.; Switzer, Mathew R.; Squire, Thomas H.
2010-01-01
Many thermal protection system materials used for spacecraft heatshields have anisotropic thermal properties, causing them to display significantly different thermal characteristics in different directions, when subjected to a heating environment during flight or arcjet tests. This paper investigates the effects of sidewall heating coupled with anisotropic thermal properties of thermal protection materials in the arcjet environment. Phenolic Impregnated Carbon Ablator (PICA) and LI-2200 materials (the insulation material of Shuttle tiles) were used for this study. First, conduction-based thermal response simulations were carried out, using the Marc.Mentat finite element solver, to study the effects of sidewall heating on PICA arcjet coupons. The simulation showed that sidewall heating plays a significant role in thermal response of these models. Arcjet tests at the Aerodynamic Heating Facility (AHF) at NASA Ames Research Center were performed later on instrumented coupons to obtain temperature history at sidewall and various radial locations. The details of instrumentation and experimental technique are the prime focus of this paper. The results obtained from testing confirmed that sidewall heating plays a significant role in thermal response of these models. The test results were later used to verify the two-dimensional ablation, thermal response, and sizing program, TITAN. The test data and model predictions were found to be in excellent agreement
NASA Astrophysics Data System (ADS)
Leal, José G. Garza; León, Ivan Hernandez; Sáenz, Lorena Castillo; Aguirre, Juan M. Aguilar; Lagos, Joel J. Islas; Parsons, Jessica E.; Darlington, Gregory P.; Lau, Michael P. H.
2017-03-01
Mirabilis Medica, Inc. (Bothell, WA, USA) has developed a high-intensity focused ultrasound (HIFU) system for producing rapid transabdominal volumetric ablation of uterine fibroids in an office-based setting. The Mirabilis HIFU Treatment System utilizes integrated ultrasound imaging guidance and short treatment times under 15 minutes. Treatment with the Mirabilis system is generally well tolerated using only oral analgesia without anesthesia or sedation. This paper summarizes certain technical aspects of the Mirabilis HIFU technology, the preclinical development process, and the results of the first in-human clinical study using the Mirabilis system. During preclinical studies, an in vivo transcutaneous porcine lower extremity model was used in a total of 180 adult swine to develop the HIFU treatment regimen parameters. Additionally, 108 excised human uteri with fibroids obtained from scheduled hysterectomies were treated in an ex vivo experimental setup and evaluated. These preclinical activities resulted in a HIFU treatment technique referred to as Mirabilis Shell Ablation, which enables rapid volumetric fibroid ablation by directing the HIFU energy to the outer perimeter of the target volume (the `shell') without insonating its core. This method results in efficient fibroid treatment through a synergistic combination of direct tissue ablation, cooperative heating effects, and indirect ischemic necrosis in the interior of the volume. After refining this technique and performing safety testing in the in vivo porcine model, a clinical pilot study was conducted to assess the initial safety and performance of the Mirabilis HIFU Treatment System for transabdominal treatment of uterine fibroids in eligible women who were scheduled to undergo hysterectomy following treatment with the device. A total of 37 women meeting certain eligibility criteria were treated at two clinical sites in Mexico. Twenty-nine (29) of these 37 women received only prophylactic sublingual analgesics (tramadol and/or ketorolac) prior to treatment, and 19 out of 37 also underwent post-treatment gadolinium-enhanced magnetic resonance imaging (MRI) to assess the HIFU-mediated non-perfused volumes (NPVs) created within their fibroid(s). All subjects then received their scheduled hysterectomies as planned between 0 and 155 days after HIFU treatment, and the excised uteri were assessed by a pathologist using a viability staining procedure to measure the dimensions of the ablated volumes. Subjects were followed for adverse event episodes for two weeks post-treatment or until discharge after their hysterectomy, whichever was later. During this clinical pilot study, an excellent safety record was observed. There were no observations of skin burns or other injury to any tissues outside the uterus. No serious or unanticipated adverse events related to treatment were reported. Among the 29 subjects receiving only oral analgesia prior to treatment, the average intra-procedural pain score reported was 2.4 ± 2.5 on a scale of 0-10 (mean ± standard deviation). The average total treatment time from start to finish for all 37 patients was 4.9 ± 2.4 minutes. The resultant ablated volume, quantified from either post-treatment MRI or pathology assessment, was controllable via adjustment of the HIFU energy dose delivered. At the highest energy dose range used (8-10 kJ), an average ablated volume of 51 ± 50 cc was produced in an average of 7.0 ± 0.9 minutes. All ablated volumes ranged between 0 and 123 cc. These preliminary clinical results indicate that noninvasive fibroid treatment with the Mirabilis system is well tolerated using only oral analgesia, has a low rate of adverse device effects, and can be performed rapidly in an office-based setting.
Wang, Geng; Wang, Heyang; Xu, Bo; Yang, Yuejin; Yang, Zhiming; Li, Hui; Zhang, Zheng; Wang, Haichang; Yang, Lixia; Han, Yaling
2017-03-01
The safety and efficacy of the second-generation biodegradable polymer Cobalt-Chromium sirolimus-eluting stent (EXCEL2) in daily clinical practice remains unknown. Additionally, to meet the China Food and Drug Administration requirements, we conducted an objective performance criterion study from the CREDIT II and CREDIT III trials. CREDIT II was a randomized trial comparing the EXCEL2 versus EXCEL stent in patients with up to 2 de novo coronary lesions. CREDIT III was a prospective, single-arm study evaluating the efficacy and safety of EXCEL2 in broad types of de novo coronary artery lesions. This pooled analysis included patients in the CREDIT III and EXCEL2 arm of the CREDIT II trial. The primary outcome was 12-month target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI), and clinical indicated target lesion revascularization (CI-TLR). The patient-oriented composite endpoint (PoCE) of all-cause death, all MI, or any revascularization was also analyzed. A total of 833 patients were included, consisting of 625 in the CREDIT III trial and 208 in the EXCEL2 arm of the CREDIT II trial. Twelve-month TLF occurred in 6.1% patients, cardiac death in 0.4%, TV-MI in 5%, and CI-TLR in 1.1%. Additionally, 64 (7.7%) PoCE and 3 probable late stent thromboses (0.4%) were recorded. EXCEL2 stent met the objective performance criterion on efficacy and safety with a low level of 12-month TLF as well as stent thrombosis when treating patients with de novo coronary lesions. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Electric papers of graphene-coated Co₃O₄ fibers for high-performance lithium-ion batteries.
Yang, Xiaoling; Fan, Kaicai; Zhu, Yihua; Shen, Jianhua; Jiang, Xin; Zhao, Peng; Luan, Shaorong; Li, Chunzhong
2013-02-01
A facile strategy to synthesize the novel composite paper of graphene nanosheets (GNS) coated Co(3)O(4) fibers is reported as an advanced anode material for high-performance lithium-ion batteries (LIBs). The GNS were able to deposit onto Co(3)O(4) fibers and form the coating via electrostatic interactions. The unique hybrid paper is evaluated as an anode electrode for LIBs, and it exhibits a very large reversible capacity (∼840 mA h g(-1) after 40 cycles), excellent cyclic stability and good rate capacity. The substantially excellent electrochemical performance of the graphene/Co(3)O(4) composite paper is the result from its unique features. Notably, the flexible structure of graphenic scaffold and the strong interaction between graphene and Co(3)O(4) fibers are beneficial for providing excellent electronic conductivity, short transportation length for lithium ions, and elastomeric space to accommodate volume varies upon Li(+) insertion/extraction.
Skin pre-ablation and laser assisted microjet injection for deep tissue penetration.
Jang, Hun-Jae; Yeo, Seonggu; Yoh, Jack J
2017-04-01
For conventional needless injection, there still remain many unresolved issues such as the potential for cross-contamination, poor reliability of targeted delivery dose, and significantly painstaking procedures. As an alternative, the use of microjets generated with Er:YAG laser for delivering small doses with controlled penetration depths has been reported. In this study, a new system with two stages is evaluated for effective transdermal drug delivery. First, the skin is pre-ablated to eliminate the hard outer layer and second, laser-driven microjet penetrates the relatively weaker and freshly exposed epidermis. Each stage of operation shares a single Er:YAG laser that is suitable for skin ablation as well as for the generation of a microjet. In this study, pig skin is selected for quantification of the injection depth based on the two-stage procedure, namely pre-ablation and microjet injection. The three types of pre-ablation devised here consists of bulk ablation, fractional ablation, and fractional-rotational ablation. The number of laser pulses are 12, 18, and 24 for each ablation type. For fractional-rotational ablation, the fractional beams are rotated by 11.25° at each pulse. The drug permeation in the skin is evaluated using tissue marking dyes. The depth of penetration is quantified by a cross sectional view of the single spot injections. Multi-spot injections are also carried out to control the dose and spread of the drug. The benefits of a pre-ablation procedure prior to the actual microjet injection to the penetration is verified. The four possible combinations of injection are (a) microjet only; (b) bulk ablation and microjet injection; (c) fractional ablation and microjet injection; and (d) fractional-rotational ablation and microjet injection. Accordingly, the total depth increases with injection time for all cases. In particular, the total depth of penetration attained via fractional pre-ablation increased by 8 ∼ 11% and that of fractional-rotational pre-ablation increased by 13 ∼ 33%, when compared with the no pre-ablation or microjet only cases. A noticeable point is that the fraction-rotational pre-ablation and microjet result is comparable to the bulk ablation and microjet result of 11 ∼ 42%. The penetration depth underneath ablated stratum corneum (SC) is also measured in order to verify the pre-ablation effect. The penetration depths for each case are (a) 443 ± 104 µm; (b) 625 ± 98 µm; (c) 523 ± 95 µm; and (d) 595 ± 141 µm for microjet only, bulk ablation and microjet, fractional ablation and microjet, and fractional-rotational ablation and microjet, respectively. This is quite beneficial since any healing time associated with ablation is significantly reduced by avoiding hard-core bulk ablation. Thus the bulk pre-ablation and microjet may well be superseded by the less invasive fractiona-rotational ablation followed by the microjet injection. The density of micro-holes is 1.27 number/mm 2 for fractional ablation and 4.84 number/mm 2 for fractional-rotational ablation. The penetration depths measured underneath the ablated SC are 581 µm (fractional ablation and microjet) and 691 µm (fractional-rotational ablation and microjet). Fractional-rotational ablation increases number of micro-holes in a unit area, enabling fast reepithelialization and high drug delivery efficiency. Optimization of system parameters such as ablation time, number of ablations, and injection time will eventually ensure a macromolecule delivery technique with the potential to include vaccines, insulins, and growth hormones, all of which require deeper penetration into the skin. Lasers Surg. Med. 49:387-394, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Dai, Hongya; Chen, Fei; Yan, Sijing; Ding, Xiaoya; Ma, Dazhao; Wen, Jing; Xu, Die; Zou, Jianzhong
2017-01-01
Background The aim of this study was to investigate the feasibility of the application of high-intensity focused ultrasound (HIFU) hat-type ablation mode in in vitro and in vivo models, and to compare the ablation effects of different parameter combinations. Material/Methods HIFU hat-type ablation was performed in isolated bovine liver tissue and in the liver tissue in living rabbits, and the coagulative necrosis for different parameter combinations (plane angles and irradiation order) was investigated. We also analyzed and compared the ablation effects of traditional ablation and hat-type ablation modes. Coagulative necrosis morphology was detected with TTC staining, and the coagulative necrosis volume and energy efficiency factor (EEF) were calculated and compared. Results Coagulative necrosis was observed in all the ablated groups, and the coagulative necrosis volume was much larger than the irradiation area. The coagulative necrosis induced by the hat-type ablation was more regular and controllable than the traditional ablation. The angles between the ablation planes determined the coagulative necrosis morphology, but did not affect the coagulative necrosis volume. Moreover, the irradiation order significantly influenced the coagulative necrosis. Importantly, under certain conditions, hat-type ablation achieved higher efficiency compared with the traditional ablation mode. Conclusions Compared with the traditional ablation mode, HIFU hat-type ablation effectively shortened the irradiation time, reduced the over-accumulation of energy, and increased the HIFU ablation efficiency. PMID:28699626
Dai, Hongya; Chen, Fei; Yan, Sijing; Ding, Xiaoya; Ma, Dazhao; Wen, Jing; Xu, Die; Zou, Jianzhong
2017-07-12
BACKGROUND The aim of this study was to investigate the feasibility of the application of high-intensity focused ultrasound (HIFU) hat-type ablation mode in in vitro and in vivo models, and to compare the ablation effects of different parameter combinations. MATERIAL AND METHODS HIFU hat-type ablation was performed in isolated bovine liver tissue and in the liver tissue in living rabbits, and the coagulative necrosis for different parameter combinations (plane angles and irradiation order) was investigated. We also analyzed and compared the ablation effects of traditional ablation and hat-type ablation modes. Coagulative necrosis morphology was detected with TTC staining, and the coagulative necrosis volume and energy efficiency factor (EEF) were calculated and compared. RESULTS Coagulative necrosis was observed in all the ablated groups, and the coagulative necrosis volume was much larger than the irradiation area. The coagulative necrosis induced by the hat-type ablation was more regular and controllable than the traditional ablation. The angles between the ablation planes determined the coagulative necrosis morphology, but did not affect the coagulative necrosis volume. Moreover, the irradiation order significantly influenced the coagulative necrosis. Importantly, under certain conditions, hat-type ablation achieved higher efficiency compared with the traditional ablation mode. CONCLUSIONS Compared with the traditional ablation mode, HIFU hat-type ablation effectively shortened the irradiation time, reduced the over-accumulation of energy, and increased the HIFU ablation efficiency.
Hard tissue ablation with a spray-assisted mid-IR laser
NASA Astrophysics Data System (ADS)
Kang, H. W.; Rizoiu, I.; Welch, A. J.
2007-12-01
The objective of this study was to understand the dominant mechanism(s) for dental enamel ablation with the application of water spray. A free-running Er,Cr:YSGG (yttrium, scandium, gallium, garnet) laser was used to ablate human enamel tissue at various radiant exposures. During dental ablation, distilled water was sprayed on the sample surface, and these results were compared to ablation without a spray (dry ablation). In order to identify dominant ablation mechanisms, transient acoustic waves were compared to ablation thresholds and the volume of material removed. The ablation profile and depth were measured using optical coherence tomography (OCT). Irregular surface modification, charring and peripheral cracks were associated with dry ablation, whereas craters for spray samples were relatively clean without thermal damage. In spite of a 60% higher ablation threshold for spray associated irradiations owing to water absorption, acoustic peak pressures were six times higher and ablation volume was up to a factor of 2 larger compared to dry ablation. The enhanced pressure and ablation performance of the spray-assisted process was the result of rapid water vaporization, material ejection with recoil stress, interstitial water explosion and possibly liquid-jet formation. With water cooling and abrasive/disruptive mechanical effects, the spray ablation can be a safe and efficient modality for dental treatment.
1985-12-18
during excimer laser ablation. Results are %%% Study on the Mechanism of Ion-Assisted Etching, F. H. M. correlated with interferometric measurements of...report on real time interferometric measurements of free electron density and laser induced .,- fluorescence studies of atoms and molecules in the...compared with morphology exam- Ined with Nomarski micrographs and SEM. In addition, the struc- ture and composition of the deposited lines were analysed
NASA Astrophysics Data System (ADS)
Serrano, J.; Cabalín, L. M.; Moros, J.; Laserna, J. J.
2014-07-01
Since its invention in 2004, graphene has attracted considerable interest worldwide. Advances in the use of graphene in materials science and engineering require important increases in the quality of the final product for integration in photonic and electronic devices. To meet this demand, which will become increasingly strict in the future, analytical techniques capable of differentiating between the starting materials and graphene need to be developed. The interest in the use of laser-induced breakdown spectroscopy (LIBS) for this application rests on the rapid progress experienced by this technology for identification of carbon-based materials of close chemical composition. The potential of LIBS has been explored here by a careful investigation of the spectral properties of both multi-layer and few-layer graphene, graphite and graphene oxide. Results reveal significant differences in the specific optical emission responses of these materials, expressly reflected on the behavior of CN and C2 molecular emissions. These differences result from the particularities of the materials, such as the number of carbon layers and the carbon hybridization in the bonding structure, together with the post-ablation evolution of the concerned plasma plume. In short, this interconnection between ablation and emission events generated from each material allows its characterization and its differentiation from other materials with highly similar chemical composition.
Tungsten oxide-Au nanosized film composites for glucose oxidation and sensing in neutral medium
Gougis, Maxime; Ma, Dongling; Mohamedi, Mohamed
2015-01-01
In this work, we report for the first time the use of tungsten oxide (WOx) as catalyst support for Au toward the direct electrooxidation of glucose. The nanostructured WOx/Au electrodes were synthesized by means of laser-ablation technique. Both micro-Raman spectroscopy and transmission electron microscopy showed that the produced WOx thin film is amorphous and made of ultrafine particles of subnanometer size. X-ray diffraction and X-ray photoelectron spectroscopy revealed that only metallic Au was present at the surface of the WOx/Au composite, suggesting that the WOx support did not alter the electronic structure of Au. The direct electrocatalytic oxidation of glucose in neutral medium such as phosphate buffered saline (pH 7.2) solution has been investigated with cyclic voltammetry, chronoamperometry, and square-wave voltammetry. Sensitivity as high as 65.7 μA cm−2 mM−1 up to 10 mM of glucose and a low detection limit of 10 μM were obtained with square-wave voltammetry. This interesting analytical performance makes the laser-fabricated WOx/Au electrode potentially promising for implantable glucose fuel cells and biomedical analysis as the evaluation of glucose concentration in biological fluids. Finally, owing to its unique capabilities proven in this work, it is anticipated that the laser-ablation technique will develop as a fabrication tool for chip miniature-sized sensors in the near future. PMID:25931820
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tanaka, Toshihiro, E-mail: toshihir@bf6.so-net.ne.jp; Westphal, Saskia, E-mail: swestphal@ukaachen.de; Isfort, Peter, E-mail: isfort@hia.rwth-aachen.de
2012-08-15
Purpose: To compare the effectiveness of microwave (MW) ablation with radiofrequency (RF) ablation for treating breast tissue in a nonperfused ex vivo model of healthy bovine udder tissue. Materials and Methods: MW ablations were performed at power outputs of 25W, 35W, and 45W using a 915-MHz frequency generator and a 2-cm active tip antenna. RF ablations were performed with a bipolar RF system with 2- and 3-cm active tip electrodes. Tissue temperatures were continuously monitored during ablation. Results: The mean short-axis diameters of the coagulation zones were 1.34 {+-} 0.14, 1.45 {+-} 0.13, and 1.74 {+-} 0.11 cm for MWmore » ablation at outputs of 25W, 35W, and 45W. For RF ablation, the corresponding values were 1.16 {+-} 0.09 and 1.26 {+-} 0.14 cm with electrodes having 2- and 3-cm active tips, respectively. The mean coagulation volumes were 2.27 {+-} 0.65, 2.85 {+-} 0.72, and 4.45 {+-} 0.47 cm{sup 3} for MW ablation at outputs of 25W, 35W, and 45W and 1.18 {+-} 0.30 and 2.29 {+-} 0.55 cm{sup 3} got RF ablation with 2- and 3-cm electrodes, respectively. MW ablations at 35W and 45W achieved significantly longer short-axis diameters than RF ablations (P < 0.05). The highest tissue temperature was achieved with MW ablation at 45W (P < 0.05). On histological examination, the extent of the ablation zone in MW ablations was less affected by tissue heterogeneity than that in RF ablations. Conclusion: MW ablation appears to be advantageous with respect to the volume of ablation and the shape of the margin of necrosis compared with RF ablation in an ex vivo bovine udder.« less
Song, Shixin; Xia, Shan; Jiang, Shangkun; Lv, Xue; Sun, Shulin; Li, Quanming
2018-01-01
A facile strategy is adopted to prepare carboxylic functionalized multiwalled carbon nanotube (c-MWCNT) modified high dielectric constant (high-k) poly(vinylidene fluoride) (PVDF) composites with the aid of methyl methacrylate-co-glycidyl methacrylate copolymer (MG). The MG is miscible with PVDF and the epoxy groups of the copolymer can react with the carboxylic groups of c-MWCNT, which induce the uniform dispersion of c-MWCNT and a form insulator layer on the surface of c-MWCNT. The c-MWCNTs/MG/PVDF composites with 8 vol % c-MWCNT present excellent dielectric properties with high dielectric constant (~448) and low dielectric loss (~2.36) at the frequency of 1 KHz, the dielectric loss is much lower than the c-MWCNT/PVDF composites without MG. The obvious improvement in dielectric properties ascribes to the existence of MG, which impede the direct contact of c-MWCNTs and PVDF and avoid the formation of conductive network. Therefore, we propose a practical and simple strategy for preparing composites with excellent dielectric properties, which are promising for applications in electronics devices. PMID:29495491
Song, Shixin; Xia, Shan; Jiang, Shangkun; Lv, Xue; Sun, Shulin; Li, Quanming
2018-02-27
A facile strategy is adopted to prepare carboxylic functionalized multiwalled carbon nanotube (c-MWCNT) modified high dielectric constant (high- k ) poly(vinylidene fluoride) (PVDF) composites with the aid of methyl methacrylate-co-glycidyl methacrylate copolymer (MG). The MG is miscible with PVDF and the epoxy groups of the copolymer can react with the carboxylic groups of c-MWCNT, which induce the uniform dispersion of c-MWCNT and a form insulator layer on the surface of c-MWCNT. The c-MWCNTs/MG/PVDF composites with 8 vol % c-MWCNT present excellent dielectric properties with high dielectric constant (~448) and low dielectric loss (~2.36) at the frequency of 1 KHz, the dielectric loss is much lower than the c-MWCNT/PVDF composites without MG. The obvious improvement in dielectric properties ascribes to the existence of MG, which impede the direct contact of c-MWCNTs and PVDF and avoid the formation of conductive network. Therefore, we propose a practical and simple strategy for preparing composites with excellent dielectric properties, which are promising for applications in electronics devices.
Mesoporous CLEAs-silica composite microparticles with high activity and enhanced stability
Cui, Jiandong; Jia, Shiru; Liang, Longhao; Zhao, Yamin; Feng, Yuxiao
2015-01-01
A novel enzyme immobilization approach was used to generate mesoporous enzymes-silica composite microparticles by co-entrapping gelatinized starch and cross-linked phenylalanine ammonia lyase (PAL) aggregates (CLEAs) containing gelatinized starch into biomemitic silica and subsequently removing the starch by α-amylase treatment. During the preparation process, the gelatinzed starch served as a pore-forming agent to create pores in CLEAs and biomimetic silica. The resulting mesoporous CLEAs-silica composite microparticles exhibited higher activity and stability than native PAL, conventional CLEAs, and PAL encapsulated in biomimetic silica. Furthermore, the mesoporous CLEAs-silica composite microparticles displayed good reusability due to its suitable size and mechanical properties, and had excellent stability for storage. The superior catalytic performances were attributed to the combinational unique structure from the intra-cross-linking among enzyme aggregates and hard mesoporous silica shell, which not only decreased the enzyme-support negative interaction and mass-transfer limitations, but also improved the mechanical properties and monodispersity. This approach will be highly beneficial for preparing various bioactive mesoporous composites with excellent catalytic performance. PMID:26374188
Laeseke, Paul F; Lee, Fred T; Sampson, Lisa A; van der Weide, Daniel W; Brace, Christopher L
2009-09-01
To determine whether microwave ablation with high-power triaxial antennas creates significantly larger ablation zones than radiofrequency (RF) ablation with similarly sized internally cooled electrodes. Twenty-eight 12-minute ablations were performed in an in vivo porcine kidney model. RF ablations were performed with a 200-W pulsed generator and either a single 17-gauge cooled electrode (n = 9) or three switched electrodes spaced 1.5 cm apart (n = 7). Microwave ablations were performed with one (n = 7), two (n = 3), or three (n = 2) 17-gauge triaxial antennas to deliver 90 W continuous power per antenna. Multiple antennas were powered simultaneously. Temperatures 1 cm from the applicator were measured during two RF and microwave ablations each. Animals were euthanized after ablation and ablation zone diameter, cross-sectional area, and circularity were measured. Comparisons between groups were performed with use of a mixed-effects model with P values less than .05 indicating statistical significance. No adverse events occurred during the procedures. Three-electrode RF (mean area, 14.7 cm(2)) and single-antenna microwave (mean area, 10.9 cm(2)) ablation zones were significantly larger than single-electrode RF zones (mean area, 5.6 cm(2); P = .001 and P = .0355, respectively). No significant differences were detected between single-antenna microwave and multiple-electrode RF. Ablation zone circularity was similar across groups (P > .05). Tissue temperatures were higher during microwave ablation (maximum temperature of 123 degrees C vs 100 degrees C for RF). Microwave ablation with high-power triaxial antennas created larger ablation zones in normal porcine kidneys than RF ablation with similarly sized applicators.
Wang, Yan; Gu, Fu-Qiang; Ni, Li-Juan; Liang, Kun; Marcus, Kyle; Liu, Shu-Li; Yang, Fan; Chen, Jin-Ju; Feng, Zhe-Sheng
2017-11-30
Conductive polymer composites (CPCs) containing nanoscale conductive fillers have been widely studied for their potential use in various applications. In this paper, polypyrrole (PPy)/polydopamine (PDA)/silver nanowire (AgNW) composites with high electromagnetic interference (EMI) shielding performance, good adhesion ability and light weight are successfully fabricated via a simple in situ polymerization method followed by a mixture process. Benefiting from the intrinsic adhesion properties of PDA, the adhesion ability and mechanical properties of the PPy/PDA/AgNW composites are significantly improved. The incorporation of AgNWs endows the functionalized PPy with tunable electrical conductivity and enhanced EMI shielding effectiveness (SE). By adjusting the AgNW loading degree in the PPy/PDA/AgNW composites from 0 to 50 wt%, the electrical conductivity of the composites greatly increases from 0.01 to 1206.72 S cm -1 , and the EMI SE of the composites changes from 6.5 to 48.4 dB accordingly (8.0-12.0 GHz, X-band). Moreover, due to the extremely low density of PPy, the PPy/PDA/AgNW (20 wt%) composites show a superior light weight of 0.28 g cm -3 . In general, it can be concluded that the PPy/PDA/AgNW composites with tunable electrical conductivity, good adhesion properties and light weight can be used as excellent EMI shielding materials.
Light weight fire resistant graphite composites
NASA Technical Reports Server (NTRS)
Kourtides, D. A.; Parker, J. A.; Hsu, M. T. S.
1986-01-01
Composite structures with a honeycomb core and characterized by lightweight and excellent fire resistance are provided. These sandwich structures employ facesheets made up of bismaleimide-vinyl styrylpyridine copolymers with fiber reinforcement such as carbon fiber reinforcement. In preferred embodiments the facesheets are over layered with a decorative film. The properties of these composites make them attractive materials of construction aircraft and spacecraft.
Yamada, Takumi; Maddox, William R; McElderry, H Thomas; Doppalapudi, Harish; Plumb, Vance J; Kay, G Neal
2015-04-01
Idiopathic ventricular arrhythmias (VAs) originating from the left ventricular outflow tract (LVOT) sometimes require catheter ablation from the endocardial and epicardial sides for their elimination, suggesting the presence of intramural VA foci. This study investigated the efficacy of sequential and simultaneous unipolar radiofrequency catheter ablation from the endocardial and epicardial sides in treating intramural LVOT VAs. Fourteen consecutive LVOT VAs, which required sequential or simultaneous irrigated unipolar radiofrequency ablation from the endocardial and epicardial sides for their elimination, were studied. The first ablation was performed at the site with the earliest local ventricular activation and best pace map on the endocardial or epicardial side. When the first ablation was unsuccessful, the second ablation was delivered on the other surface. If this sequential unipolar ablation failed, simultaneous unipolar ablation from both sides was performed. The first ablation was performed on the epicardial side in 9 VAs and endocardial side in 5 VAs. The intramural LVOT VAs were successfully eliminated by the sequential (n=9) or simultaneous (n=5) unipolar catheter ablation. Simultaneous ablation was most likely to be required for the elimination of the VAs when the distance between the endocardial and epicardial ablation sites was >8 mm and the earliest local ventricular activation time relative to the QRS onset during the VAs of <-30 ms was recorded at those ablation sites. LVOT VAs originating from intramural foci could usually be eliminated by sequential unipolar radiofrequency ablation and sometimes required simultaneous ablation from both the endocardial and epicardial sides. © 2015 American Heart Association, Inc.
Tracing fetal and childhood exposure to lead using isotope analysis of deciduous teeth
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shepherd, Thomas J.; British Geological Survey, Keyworth, Nottingham; Dirks, Wendy
We report progress in using the isotopic composition and concentration of Pb in the dentine and enamel of deciduous teeth to provide a high resolution time frame of exposure to Pb during fetal development and early childhood. Isotope measurements (total Pb and {sup 208}Pb/{sup 206}Pb, {sup 207}Pb/{sup 206}Pb ratios) were acquired by laser ablation inductively coupled mass spectrometry at contiguous 100 micron intervals across thin sections of the teeth; from the outer enamel surface to the pulp cavity. Teeth samples (n=10) were selected from two cohorts of children, aged 5–8 years, living in NE England. By integrating the isotope datamore » with histological analysis of the teeth, using the daily incremental lines in dentine, we were able to assign true estimated ages to each ablation point (first 2–3 years for molars, first 1–2 years for incisors+pre-natal growth). Significant differences were observed in the isotope composition and concentration of Pb between children, reflecting differences in the timing and sources of exposure during early childhood. Those born in 2000, after the withdrawal of leaded petrol in 1999, have the lowest dentine Pb levels (<0.2 µg Pb/g) with {sup 208}Pb/{sup 206}Pb (mean ±2σ: 2.126–2.079) {sup 208}Pb/{sup 206}Pb (mean ±2σ: 0.879–0.856) ratios that correlate very closely with modern day Western European industrial aerosols (PM{sub 10}, PM{sub 2.5}) suggesting that diffuse airborne pollution was probably the primary source and exposure pathway. Legacy lead, if present, is insignificant. For those born in 1997, dentine lead levels are typically higher (>0.4 µgPb/g) with {sup 208}Pb/{sup 206}Pb (mean ±2σ: 2.145–2.117) {sup 208}Pb/{sup 206}Pb (mean ±2σ: 0.898–0.882) ratios that can be modelled as a binary mix between industrial aerosols and leaded petrol emissions. Short duration, high intensity exposure events (1–2 months) were readily identified, together with evidence that dentine provides a good proxy for childhood changes in the isotope composition of blood Pb. Our pilot study confirms that laser ablation Pb isotope analysis of deciduous teeth, when carried out in conjunction with histological analysis, permits a reconstruction of the timing, duration and source of exposure to Pb during early childhood. With further development, this approach has the potential to study larger cohorts and appraise environments where the levels of exposure to Pb are much higher. - Highlights: • Reconstructing a high resolution chronology of early childhood exposure to lead. • Combined laser ablation lead isotope – histological analysis of children's teeth. • Using dentine to recover information on the intensity, duration and source of lead. • Importance of industrial airborne lead pollution in a post-leaded petrol era.« less
NASA Astrophysics Data System (ADS)
Tulej, M.; Riedo, A.; Meyer, S.; Iakovleva, M.; Neuland, M.; Wurz, P.
2012-04-01
Detailed knowledge of the elemental and isotopic composition of solar system objects imposes critical constraints on models describing the origin of our solar system and can provide insight to chemical and physical processes taking place during the planetary evolution. So far, the investigation of chemical composition of planetary surfaces could be conducted almost exclusively by remotely controlled spectroscopic instruments from orbiting spacecraft, landers or rovers. With some exceptions, the sensitivity of these techniques is, however, limited and often only abundant elements can be investigated. Nevertheless, the spectroscopic techniques proved to be successful for global chemical mapping of entire planetary objects such as the Moon, Mars and asteroids. A combined afford of the measurements from orbit, landers and rovers can also yield the determination of local mineralogy. New instruments including Laser Induced Breakdown Spectroscopy (LIBS) and Laser Ablation/Ionisation Mass Spectrometer (LIMS), have been recently included for several landed missions. LIBS is thought to improve flexibility of the investigations and offers a well localised chemical probing from distances up to 10-13 m. Since LIMS is a mass spectrometric technique it allows for very sensitive measurements of elements and isotopes. We will demonstrate the results of the current performance tests obtained by application of a miniaturised laser ablation/ionisation mass spectrometer, a LIMS instrument, developed in Bern for the chemical analysis of solids. So far, the only LIMS instrument on a spacecraft is the LAZMA instrument. This spectrometer was a part of the payload for PHOBOS-GRUNT mission and is also currently selected for LUNA-RESURCE and LUNA-GLOB missions to the lunar south poles (Managadze et al., 2011). Our LIMS instrument has the dimensions of 120 x Ø60 mm and with a weight of about 1.5 kg (all electronics included), it is the lightest mass analyser designed for in situ chemical analysis of solid materials on the planetary surfaces (Rohner et al., 2003). Initial laboratory tests that were conducted with an IR laser radiation for the ablation, atomisation and ionisation of the material, indicated a high performance of the instrument in terms of sensitivity, dynamic range and mass resolution (Tulej et al., 2011). After some technical improvements and implementation of a computer-controlled performance optimiser we have achieved further improvements of both, the instrumental sensitivity down to sub-ppm level and reproducibility of the measurements. We will demonstrate the potential of the mass analyser to perform the quantitative elemental analysis of solids with a spatial (vertical, lateral) resolution commensurate with typical grain sizes, and its capabilities for investigation of isotopic patterns with accuracy and precision comparable to that of large analytical laboratory instruments, e.g., TIMS, SIMS, LA-ICP-MS. The results can be of considerable interest for in situ dating or investigation of other fine isotopic fractionation effects including studies of bio-markers.
Kim, Jong-Woo; Shin, Kwan-Ha; Koh, Young-Hag; Hah, Min Jin; Moon, Jiyoung; Kim, Hyoun-Ee
2017-01-01
We produced poro-us poly(ε-caprolactone) (PCL)/hydroxyapatite (HA) composite scaffolds for bone regeneration, which can have a tailored macro/micro-porous structure with high mechanical properties and excellent in vitro bioactivity using non-solvent-induced phase separation (NIPS)-based 3D plotting. This innovative 3D plotting technique can create highly microporous PCL/HA composite filaments by inducing unique phase separation in PCL/HA solutions through the non-solvent-solvent exchange phenomenon. The PCL/HA composite scaffolds produced with various HA contents (0 wt %, 10 wt %, 15 wt %, and 20 wt %) showed that PCL/HA composite struts with highly microporous structures were well constructed in a controlled periodic pattern. Similar levels of overall porosity (~78 vol %) and pore size (~248 µm) were observed for all the PCL/HA composite scaffolds, which would be highly beneficial to bone tissue regeneration. Mechanical properties, such as ultimate tensile strength and compressive yield strength, increased with an increase in HA content. In addition, incorporating bioactive HA particles into the PCL polymer led to remarkable enhancements in in vitro apatite-forming ability. PMID:28937605
NASA Astrophysics Data System (ADS)
Zhang, Xiaoxing; Tan, Jipeng; Xu, Xinxin; Shi, Fanian; Li, Guanglu; Yang, Yiqiao
2017-09-01
A composite material has been obtained successfully through the loading of nanoscale coordination polymer on magnetic Fe3O4@SiO2 core-shell particle. In this composite material, coordination polymer nanoparticles distribute uniformly on Fe3O4@SiO2 and these two components are "tied" together firmly with chemical bonds. Adsorption experiments suggest this composite material exhibits very excellent selectivity to hemoglobin. But under the same condition, its adsorption to bovine serum albumin can almost be ignored. This selectivity can be attributed to the existence of hydrophobic interactions between coordination polymer nanoparticle and hemoglobin. For composite material, the hemoglobin adsorption process follows Langmuir model perfectly with high speed. The adsorbed hemoglobin can be eluted easily by sodium dodecyl sulfate stripping reagent with structure and biological activity of hemoglobin keeps well. The composite material was also employed to separate hemoglobin from human whole blood, which receives a very satisfactory result. Furthermore, magnetic measurement reveals ferromagnetic character of this composite material with magnetization saturation 3.56 emu g-1 and this guarantees its excellent magnetic separation performance from the treated solution.
An Amorphous Carbon Nitride Composite Derived from ZIF-8 as Anode Material for Sodium-Ion Batteries.
Fan, Jing-Min; Chen, Jia-Jia; Zhang, Qian; Chen, Bin-Bin; Zang, Jun; Zheng, Ming-Sen; Dong, Quan-Feng
2015-06-08
An composite comprising amorphous carbon nitride (ACN) and zinc oxide is derived from ZIF-8 by pyrolysis. The composite is a promising anode material for sodium-ion batteries. The nitrogen content of the ACN composite is as high as 20.4 %, and the bonding state of nitrogen is mostly pyridinic, as determined by X-ray photoelectron spectroscopy (XPS). The composite exhibits an excellent Na(+) storage performance with a reversible capacity of 430 mA h g(-1) and 146 mA h g(-1) at current densities of 83 mA g(-1) and 8.33 A g(-1) , respectively. A specific capacity of 175 mA h g(-1) was maintained after 2000 cycles at 1.67 A g(-1) , with only 0.016 % capacity degradation per cycle. Moreover, an accelerating rate calorimetry (ARC) test demonstrates the excellent thermal stability of the composite, with a low self heating rate and high onset temperature (210 °C). These results shows its promise as a candidate material for high-capacity, high-rate anodes for sodium-ion batteries. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Preparation of graphite dispersed copper composite on copper plate with CO2 laser
NASA Astrophysics Data System (ADS)
Yokoyama, S.; Ishikawa, Y.; Muizz, M. N. A.; Hisyamudin, M. N. N.; Nishiyama, K.; Sasano, J.; Izaki, M.
2018-01-01
It was tried in this work to prepare the graphite dispersed copper composite locally on a copper plate with a CO2 laser. The objectives of this study were to clear whether copper graphite composite was prepared on a copper plate and how the composite was prepared. The carbon content at the laser spot decreased with the laser irradiation time. This mainly resulted from the elimination by the laser trapping. The carbon content at the outside of the laser spot increased with time. Both the laser ablation and the laser trapping did not act on the graphite particles at the outside of the laser spot. Because the copper at the outside of the laser spot melted by the heat conduction from the laser spot, the particles were fixed by the wetting. However, the graphite particles were half-floated on the copper plate. The Vickers hardness decreased with an increase with laser irradiation time because of annealing.
NASA Technical Reports Server (NTRS)
Riccitiello, S. R.; Figueroa, H.; Coe, C. F.; Kuo, C. P.
1984-01-01
An advanced leading-edge concept was analyzed using the space shuttle leading edge system as a reference model. The comparison indicates that a direct-bond system utilizing a high temperature (2700 F) fibrous refractory composite insulation tile bonded to a high temperature (PI/graphite) composite structure can result in a weight savings of up to 800 lb. The concern that tile damage or loss during ascent would result in adverse entry aerodynamics if a leading edge tile system were used is addressed. It was found from experiment that missing tiles (as many as 22) on the leading edge would not significantly affect the basic force-and-moment aerodynamic coefficients. Additionally, this concept affords a degree of redundancy to a thermal protection system in that the base structure (being a composite material) ablates and neither melts nor burns through when subjected to entry heating in the event tiles are actually lost or damaged during ascent.