Sample records for excellent correlation coefficient

  1. The inter and intra rater reliability of the Netball Movement Screening Tool.

    PubMed

    Reid, Duncan A; Vanweerd, Rebecca J; Larmer, Peter J; Kingstone, Rachel

    2015-05-01

    To establish the inter- and intra-rater reliability of the Netball Movement Screening Tool, for screening adolescent female netball players. Inter- and intra-rater reliability study. Forty secondary school netball players were recruited to take part in the study. Twenty subjects were screened simultaneously and independently by two raters to ascertain inter-rater agreement. Twenty subjects were scored by rater one on two occasions, separated by a week, to ascertain intra-rater agreement. Inter and intra-rater agreement was assessed utilising the two-way mixed inter class correlation coefficient and weighted kappa statistics. No significant demographic differences were found between the inter and intra-rater groups of subjects. Inter class correlation coefficients' demonstrated excellent inter-rater (two-way mixed inter class correlation coefficients 0.84, standard error of measurement 0.25) and intra-rater (two-way mixed inter class correlation coefficients 0.96, standard error of measurement 0.13) reliability for the overall Netball Movement Screening Tool score and substantial-excellent (two-way mixed inter class correlation coefficients 1.0-0.65) inter-rater and substantial-excellent intra-rater (two-way mixed inter class correlation coefficients 0.96-0.79) reliability for the component scores of the Netball Movement Screening Tool. Kappa statistic showed substantial to poor inter-rater (k=0.75-0.32) and intra-rater (k=0.77-0.27) agreement for individual tests of the NMST. The Netball Movement Screening Tool may be a reliable screening tool for adolescent netball players; however the individual test scores have low reliability. The screening tool can be administered reliably by raters with similar levels of training in the tool but variable clinical experience. On-going research needs to be undertaken to ascertain whether the Netball Movement Screening Tool is a valid tool in ascertaining increased injury risk for netball players. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  2. Reliability and concurrent validity of the adapted Chinese version of Scoliosis Research Society-22 (SRS-22) questionnaire.

    PubMed

    Cheung, Kenneth M C; Senkoylu, Alpaslan; Alanay, Ahmet; Genc, Yasemin; Lau, Sarah; Luk, Keith D

    2007-05-01

    Validation study to define validity and reliability of an adapted and translated questionnaire. Assessment of the concurrent validity and reliability of a Chinese version of SRS-22 outcome instrument. No valid health-related quality of life (HRQL) outcome instrument exists for patients with spinal deformity in Chinese. The modified SRS-22 questionnaire was proven to be an appropriate outcome instrument in English, and has already been translated and validated in several other languages. The English version of the SRS-22 questionnaire was adapted to Chinese according to the International Quality of Life Assessment Project guidelines. To assess reliability, 48 subjects with adolescent idiopathic scoliosis (mean age, 16.5 years) filled the questionnaire on 2 separate occasions (Group 1). To assess concurrent validity, 50 subjects (mean age, 21 years) filled in the same questionnaire and a previously validated Chinese version of the Short Form-36 (SF36) questionnaire (Group 2). Internal consistency, reproducibility and concurrent validity were determined with Cronbach's alpha coefficient, interclass correlation coefficient and Pearson correlation coefficient, respectively. Cronbach's alpha coefficient for the 4 major domains (function/activity, pain, self-image/appearance and mental health) were high. Intraclass correlation was also excellent for all domains. For concurrent validity, excellent correlation was found in 1 domain, good in 12 domains, moderate in 3 domains, and poor in 1 domain of the 17 relevant domains. Both cultural adaptation and linguistic translation are essential in any attempt to use a HRQL questionnaire across cultures. The Chinese version of the SRS-22 outcome instrument has satisfactory internal consistency and excellent reproducibility. It is ready for use in clinical studies on idiopathic scoliosis in Chinese-speaking societies.

  3. Reliability of the Balance Evaluation Systems Test (BESTest) and BESTest sections for adults with hemiparesis

    PubMed Central

    Rodrigues, Letícia C.; Marques, Aline P.; Barros, Paula B.; Michaelsen, Stella M.

    2014-01-01

    BACKGROUND: The Balance Evaluation Systems Test (BESTest) was recently created to allow the development of treatments according to the specific balance system affected in each patient. The Brazilian version of the BESTest has not been specifically tested after stroke. OBJECTIVE: To evaluate the intra- and inter-rater reliability and concurrent and convergent validity of the total score of the BESTest and BESTest sections for adults with hemiparesis after stroke. METHOD: The study included 16 subjects (61.1±7.5 years) with chronic hemiparesis (54.5±43.5 months after stroke). The BESTest was administered by two raters in the same week and one of the raters repeated the test after a one-week interval. Intraclass correlation coefficient (ICC) was calculated to assess intra- and interrater reliability. Concurrent validity with the Berg Balance Scale (BBS) and convergent validity with the Activities-specific Balance Confidence scale (ABC-Brazil) were assessed using Pearson's correlation coefficient. RESULTS: Both the BESTest total score (ICC=0.98) and the BESTest sections (ICC between 0.85 and 0.96) have excellent intrarater reliability. Interrater reliability for the total score was excellent (ICC=0.93) and, for the sections, it ranged between 0.71 and 0.94. The correlation coefficient between the BESTest and the BBS and ABC-Brazil were 0.78 and 0.59, respectively. CONCLUSIONS: The Brazilian version of the BESTest demonstrated adequate reliability when measured by sections and could identify what balance system was affected in patients after stroke. Concurrent validity was excellent with the BBS total score and good to excellent with the sections. The total scores but not the sections present adequate convergent validity with the ABC-Brazil. However, other psychometric properties should be further investigated. PMID:25003281

  4. Repeatability of chemical-shift-encoded water-fat MRI and diffusion-tensor imaging in lower extremity muscles in children.

    PubMed

    Ponrartana, Skorn; Andrade, Kristine E; Wren, Tishya A L; Ramos-Platt, Leigh; Hu, Houchun H; Bluml, Stefan; Gilsanz, Vicente

    2014-06-01

    The purpose of this study was to assess the repeatability of water-fat MRI and diffusion-tensor imaging (DTI) as quantitative biomarkers of pediatric lower extremity skeletal muscle. MRI at 3 T of a randomly selected thigh and lower leg of seven healthy children was studied using water-fat separation and DTI techniques. Muscle-fat fraction, apparent diffusion coefficient (ADC), and fractional anisotropy (FA) values were calculated. Test-retest and interrater repeatability were assessed by calculating the Pearson correlation coefficient, intraclass correlation coefficient, and Bland-Altman analysis. Bland-Altman plots show that the mean difference between test-retest and interrater measurements of muscle-fat fraction, ADC, and FA was near 0. The correlation coefficients and intraclass correlation coefficients were all between 0.88 and 0.99 (p < 0.05), suggesting excellent reliability of the measurements. Muscle-fat fraction measurements from water-fat MRI exhibited the highest intraclass correlation coefficient. Interrater agreement was consistently better than test-retest comparisons. Water-fat MRI and DTI measurements in lower extremity skeletal muscles are objective repeatable biomarkers in children. This knowledge should aid in the understanding of the number of participants needed in clinical trials when using these determinations as an outcome measure to noninvasively monitor neuromuscular disease.

  5. Measuring the Cobb angle with the iPhone in kyphoses: a reliability study.

    PubMed

    Jacquot, Frederic; Charpentier, Axelle; Khelifi, Sofiane; Gastambide, Daniel; Rigal, Regis; Sautet, Alain

    2012-08-01

    Smartphones have gained widespread use in the healthcare field to fulfill a variety of tasks. We developed a small iPhone application to take advantage of the built-in position sensor to measure angles in a variety of spinal deformities. We present a reliability study of this tool in measuring kyphotic angles. Radiographs taken from 20 different patients' charts were presented to a panel of six operators at two different times. Radiographs were measured with the protractor and the iPhone application and statistical analysis was applied to measure intraclass correlation coefficients between both measurement methods, and to measure intra- and interobserver reliability The intraclass correlation coefficient calculated between methods (i.e. CobbMeter application on the iPhone versus standard method with the protractor) was 0.963 for all measures, indicating excellent correlation was obtained between the CobbMeter application and the standard method. The interobserver correlation coefficient was 0.965. The intraobserver ICC was 0.977, indicating excellent reproductibility of measurements at different times for all operators. The interobserver ICC between fellowship trained senior surgeons and general orthopaedic residents was 0.989. Consistently, the ICC for intraobserver and interobserver correlations was higher with the CobbMeter application than with the regular protractor method. This difference was not statistically significant. Measuring kyphotic angles with the iPhone application appears to be a valid procedure and is in no way inferior to the standard way of measuring the Cobb angle in kyphotic deformities.

  6. Validity and reliability of the Brazilian version of Yale-Brown obsessive compulsive scale-shopping version (YBOCS-SV).

    PubMed

    Leite, Priscilla Lourenço; Filomensky, Tatiana Zambrano; Black, Donald W; Silva, Adriana Cardoso

    2014-08-01

    The Yale-Brown Obsessive Compulsive Scale-Shopping Version (YBOCS-SV) is considered the gold standard in the assessment of shopping severity. It is designed to assess cognitions and behaviors relating to compulsive buying behavior. The present study aims to assess the validity of the Brazilian version of this scale. For the study, composed the sample 610 participants: 588 subjects of a general population and 22 compulsive buyers. Factorial analysis was performed to assess the relations and the correlation between the YBOCS-SV, the Compulsive Buying Scale (CBS), and Richmond Compulsive Buying Scale (RCBS), was assessed using Pearson coefficient, for study of convergent and divergent validity. Cronbach's alpha coefficients were used to assess internal consistency. The results show good to excellent psychometric parameters for the YBOCS-SV in its Brazilian version. With regard to correlations, the YBOCS-SV is inversely and proportionally correlated with CBS and the RCBS, indicating that the YBOCS-SV is an excellent instrument for screening compulsive buying. The YBOCS-SV presented high alpha coefficient of Cronbach's alpha (0.92), demonstrating good reliability. The Brazilian version of the YBOCS-SV is indicated to diagnose compulsive buying disorder, and likely use for the purposes intended in the Brazilian population. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Diffusion-weighted magnetic resonance imaging in the characterization of testicular germ cell neoplasms: Effect of ROI methods on apparent diffusion coefficient values and interobserver variability.

    PubMed

    Tsili, Athina C; Ntorkou, Alexandra; Astrakas, Loukas; Xydis, Vasilis; Tsampalas, Stavros; Sofikitis, Nikolaos; Argyropoulou, Maria I

    2017-04-01

    To evaluate the difference in apparent diffusion coefficient (ADC) measurements at diffusion-weighted (DW) magnetic resonance imaging of differently shaped regions-of-interest (ROIs) in testicular germ cell neoplasms (TGCNS), the diagnostic ability of differently shaped ROIs in differentiating seminomas from nonseminomatous germ cell neoplasms (NSGCNs) and the interobserver variability. Thirty-three TGCNs were retrospectively evaluated. Patients underwent MR examinations, including DWI on a 1.5-T MR system. Two observers measured mean tumor ADCs using four distinct ROI methods: round, square, freehand and multiple small, round ROIs. The interclass correlation coefficient was analyzed to assess interobserver variability. Statistical analysis was used to compare mean ADC measurements among observers, methods and histologic types. All ROI methods showed excellent interobserver agreement, with excellent correlation (P<0.001). Multiple, small ROIs provided the lower mean ADC in TGCNs. Seminomas had lower mean ADC compared to NSGCNs for each ROI method (P<0.001). Round ROI proved the most accurate method in characterizing TGCNS. Interobserver variability in ADC measurement is excellent, irrespective of the ROI shape. Multiple, small round ROIs and round ROI proved the more accurate methods for ADC measurement in the characterization of TGCNs and in the differentiation between seminomas and NSGCNs, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Identifying presence of correlated errors in GRACE monthly harmonic coefficients using machine learning algorithms

    NASA Astrophysics Data System (ADS)

    Piretzidis, Dimitrios; Sra, Gurveer; Karantaidis, George; Sideris, Michael G.

    2017-04-01

    A new method for identifying correlated errors in Gravity Recovery and Climate Experiment (GRACE) monthly harmonic coefficients has been developed and tested. Correlated errors are present in the differences between monthly GRACE solutions, and can be suppressed using a de-correlation filter. In principle, the de-correlation filter should be implemented only on coefficient series with correlated errors to avoid losing useful geophysical information. In previous studies, two main methods of implementing the de-correlation filter have been utilized. In the first one, the de-correlation filter is implemented starting from a specific minimum order until the maximum order of the monthly solution examined. In the second one, the de-correlation filter is implemented only on specific coefficient series, the selection of which is based on statistical testing. The method proposed in the present study exploits the capabilities of supervised machine learning algorithms such as neural networks and support vector machines (SVMs). The pattern of correlated errors can be described by several numerical and geometric features of the harmonic coefficient series. The features of extreme cases of both correlated and uncorrelated coefficients are extracted and used for the training of the machine learning algorithms. The trained machine learning algorithms are later used to identify correlated errors and provide the probability of a coefficient series to be correlated. Regarding SVMs algorithms, an extensive study is performed with various kernel functions in order to find the optimal training model for prediction. The selection of the optimal training model is based on the classification accuracy of the trained SVM algorithm on the same samples used for training. Results show excellent performance of all algorithms with a classification accuracy of 97% - 100% on a pre-selected set of training samples, both in the validation stage of the training procedure and in the subsequent use of the trained algorithms to classify independent coefficients. This accuracy is also confirmed by the external validation of the trained algorithms using the hydrology model GLDAS NOAH. The proposed method meet the requirement of identifying and de-correlating only coefficients with correlated errors. Also, there is no need of applying statistical testing or other techniques that require prior de-correlation of the harmonic coefficients.

  9. Validation of a New Metric for Assessing the Integration of Health Protection and Health Promotion in a Sample of Small- and Medium-Sized Employer Groups.

    PubMed

    Williams, Jessica A R; Nelson, Candace C; Cabán-Martinez, Alberto J; Katz, Jeffrey N; Wagner, Gregory R; Pronk, Nicolaas P; Sorensen, Glorian; McLellan, Deborah L

    2015-09-01

    To conduct validation analyses for a new measure of the integration of worksite health protection and health promotion approaches developed in earlier research. A survey of small- to medium-sized employers located in the United States was conducted between October 2013 and March 2014 (n = 111). Cronbach α coefficient was used to assess reliability, and Pearson correlation coefficients were used to assess convergent validity. The integration score was positively associated with the measures of occupational safety and health and health promotion activities/policies-supporting its convergent validity (Pearson correlation coefficients of 0.32 to 0.47). Cronbach α coefficient was 0.94, indicating excellent reliability. The integration score seems to be a promising tool for assessing integration of health promotion and health protection. Further work is needed to test its dimensionality and validate its use in other samples.

  10. Validity and reliability of the Japanese version of the FIM + FAM in patients with cerebrovascular accident.

    PubMed

    Miki, Emi; Yamane, Shingo; Yamaoka, Mai; Fujii, Hiroe; Ueno, Hiroka; Kawahara, Toshie; Tanaka, Keiko; Tamashiro, Hiroaki; Inoue, Eiji; Okamoto, Takatsugu; Kuriyama, Masaru

    2016-09-01

    The study aim was to investigate the validity and reliability of the Functional Independence Measure and Functional Assessment Measure (FIM + FAM), which is unfamiliar in Japan, by using its Japanese version (FIM + FAM-j) in patients with cerebrovascular accident (CVA). Forty-two CVA patients participated. Criterion validity was examined by correlating the full scale and subscales of FIM + FAM-j with several well-established measurements using Spearman's correlation coefficient. Reliability was evaluated by internal consistency (tested by Cronbach's alpha coefficient) and intra-rater reliability (tested by Kendall's tau correlation coefficient). Good-to-excellent criterion validity was found between the full scale and motor subscales of the FIM + FAM-j and the Barthel Index, National Institutes of Health Stroke Scale, modified Rankin Scale, and lower extremity Brunnstrom Recovery Stage. High internal consistency was observed within the full-scale FIM + FAM-j and the motor and cognitive subscales (Cronbach's alphas were 0.968, 0.954, and 0.948, respectively). Additionally, good intra-rater reliability was observed within the full scale and motor subscales, and excellent reliability for the cognitive subscales (taus were 0.83, 0.80, and 0.98, respectively). This study showed that the FIM + FAM-j demonstrated acceptable levels of validity and reliability when used for CVA as a measure of disability.

  11. The concurrent validity and intrarater reliability of the Microsoft Kinect to measure thoracic kyphosis.

    PubMed

    Quek, June; Brauer, Sandra G; Treleaven, Julia; Clark, Ross A

    2017-09-01

    This study aims to investigate the concurrent validity and intrarater reliability of the Microsoft Kinect to measure thoracic kyphosis against the Flexicurve. Thirty-three healthy individuals (age: 31±11.0 years, men: 17, height: 170.2±8.2 cm, weight: 64.2±12.0 kg) participated, with 29 re-examined for intrarater reliability 1-7 days later. Thoracic kyphosis was measured using the Flexicurve and the Microsoft Kinect consecutively in both standing and sitting positions. Both the kyphosis index and angle were calculated. The Microsoft Kinect showed excellent concurrent validity (intraclass correlation coefficient=0.76-0.82) and reliability (intraclass correlation coefficient=0.81-0.98) for measuring thoracic kyphosis (angle and index) in both standing and sitting postures. This study is the first to show that the Microsoft Kinect has excellent validity and intrarater reliability to measure thoracic kyphosis, which is promising for its use in the clinical setting.

  12. Reproducibility of intraocular pressure peak and fluctuation of the water-drinking test.

    PubMed

    Hatanaka, Marcelo; Alencar, Luciana M; De Moraes, Carlos G; Susanna, Remo

    2013-01-01

    The water-drinking test has been used as a stress test to evaluate the drainage system of the eye. However, in order to be clinically applicable,a test must provide reproducible results with consistent measurements. This study was performed to verify the reproducibility of intraocular pressure peaks and fluctuation detected during the water-drinking test in patients with ocular hypertension and open-angle glaucoma. A prospective analysis of patients in a tertiary care unit for glaucoma treatment. Twenty-four ocular hypertension and 64 open-angle glaucoma patients not under treatment. The water-drinking test was performed in 2 consecutive days by the same examiners in patients not under treatment. Reproducibility was assessed using the intraclass correlation coefficient. Peak and fluctuation of intraocular pressure obtained with the water-drinking test were analysed for reproducibility. Eighty-eight eyes from 24 ocular hypertension and 64 open-angle glaucoma patients not under treatment were evaluated. Test and retest intraocular pressure peak values were 28.38 ± 4.64 and 28.38 ± 4.56 mmHg, respectively (P = 1.00). Test and retest intraocular pressure fluctuation values were 5.75 ± 3.9 and 4.99 ± 2.7 mmHg, respectively (P = 0.06). Based on intraclass coefficient, reproducibility was excellent for peak intraocular pressure (intraclass correlation coefficient = 0.79) and fair for intraocular pressure fluctuation (intraclass correlation coefficient = 0.37). Intraocular pressure peaks detected during the water-drinking test presented excellent reproducibility, whereas the reproducibility of fluctuation was considered fair. © 2012 The Authors. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.

  13. Size exclusion chromatography and viscometry in paper degradation studies. New Mark-Houwink coefficients for cellulose in cupri-ethylenediamine.

    PubMed

    Łojewski, Tomasz; Zieba, Katarzyna; Lojewska, Joanna

    2010-10-15

    The paper deals with the application of size exclusion chromatography (SEC) for the studies of paper degradation phenomena. The goal is to solve some of the technical problems connected with the calibration of multi-detector SEC system and to find the correlation between SEC and viscometric results of degree of polymerization of cellulose. The results gathered for the paper samples degraded by acidic air pollutant (NO(2)) are used as an example of SEC-MALLS application. From the correlation between intrinsic viscosities and absolute value of molecular masses obtained with SEC/MALLS (Multi Angle Laser Light Scattering) technique, Mark-Houwink coefficients for cellulose in cupri-ethylenediamine solution were determined. Thus obtained coefficients were used for the determination of viscometric degree of polymerization (molecular mass) of the aged samples. An excellent correlation was found between the chromatographic values of molecular masses obtained with SEC-UV/VIS detection and the viscometric ones utilizing the improved values of Mark-Houwink coefficients. Copyright © 2010 Elsevier B.V. All rights reserved.

  14. Continuous opacity from Ne^-

    NASA Astrophysics Data System (ADS)

    John, T. L.

    1996-04-01

    Free-free absorption coefficients of the negative neon ion are calculated by the phase-shift approximation based on multiconfiguration Hartree-Fock continuum wave functions. These wave functions accurately account for electron-neon correlation and polarization, and yield scattering cross-sections in excellent agreement with the latest experimental values. The coefficients are expected to give the best current estimates of Ne^- continuous absorption. We find that Ne^- makes only a small contribution (less than 0.3 per cent) to stellar opacities, including hydrogen-deficient stars with enhanced Ne abundances.

  15. Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity

    PubMed Central

    Nicholas, Kevin; Sparkes, Valerie; Sheeran, Liba; Davies, Jennifer L

    2018-01-01

    The aim of this study was to investigate the reliability and concurrent validity of a commercially available Xsens MVN BIOMECH inertial-sensor-based motion capture system during clinically relevant functional activities. A clinician with no prior experience of motion capture technologies and an experienced clinical movement scientist each assessed 26 healthy participants within each of two sessions using a camera-based motion capture system and the MVN BIOMECH system. Participants performed overground walking, squatting, and jumping. Sessions were separated by 4 ± 3 days. Reliability was evaluated using intraclass correlation coefficient and standard error of measurement, and validity was evaluated using the coefficient of multiple correlation and the linear fit method. Day-to-day reliability was generally fair-to-excellent in all three planes for hip, knee, and ankle joint angles in all three tasks. Within-day (between-rater) reliability was fair-to-excellent in all three planes during walking and squatting, and poor-to-high during jumping. Validity was excellent in the sagittal plane for hip, knee, and ankle joint angles in all three tasks and acceptable in frontal and transverse planes in squat and jump activity across joints. Our results suggest that the MVN BIOMECH system can be used by a clinician to quantify lower-limb joint angles in clinically relevant movements. PMID:29495600

  16. Consistency of clinical biomechanical measures between three different institutions: implications for multi-center biomechanical and epidemiological research.

    PubMed

    Myer, Gregory D; Wordeman, Samuel C; Sugimoto, Dai; Bates, Nathaniel A; Roewer, Benjamin D; Medina McKeon, Jennifer M; DiCesare, Christopher A; Di Stasi, Stephanie L; Barber Foss, Kim D; Thomas, Staci M; Hewett, Timothy E

    2014-05-01

    Multi-center collaborations provide a powerful alternative to overcome the inherent limitations to single-center investigations. Specifically, multi-center projects can support large-scale prospective, longitudinal studies that investigate relatively uncommon outcomes, such as anterior cruciate ligament injury. This project was conceived to assess within- and between-center reliability of an affordable, clinical nomogram utilizing two-dimensional video methods to screen for risk of knee injury. The authors hypothesized that the two-dimensional screening methods would provide good-to-excellent reliability within and between institutions for assessment of frontal and sagittal plane biomechanics. Nineteen female, high school athletes participated. Two-dimensional video kinematics of the lower extremity during a drop vertical jump task were collected on all 19 study participants at each of the three facilities. Within-center and between-center reliability were assessed with intra- and inter-class correlation coefficients. Within-center reliability of the clinical nomogram variables was consistently excellent, but between-center reliability was fair-to-good. Within-center intra-class correlation coefficient for all nomogram variables combined was 0.98, while combined between-center inter-class correlation coefficient was 0.63. Injury risk screening protocols were reliable within and repeatable between centers. These results demonstrate the feasibility of multi-site biomechanical studies and establish a framework for further dissemination of injury risk screening algorithms. Specifically, multi-center studies may allow for further validation and optimization of two-dimensional video screening tools. 2b.

  17. Reliability and Validity of the TIMPSI for Infants With Spinal Muscular Atrophy Type I

    PubMed Central

    Krosschell, Kristin J.; Maczulski, Jo Anne; Scott, Charles; King, Wendy; Hartman, Jill T.; Case, Laura E.; Viazzo-Trussell, Donata; Wood, Janine; Roman, Carolyn A.; Hecker, Eva; Meffert, Marianne; Léveillé, Maude; Kienitz, Krista; Swoboda, Kathryn J.

    2014-01-01

    Purpose This study examined the reliability and validity of the Test of Infant Motor Performance Screening Items (TIMPSI) in infants with type I spinal muscular atrophy (SMA). Methods After training, 12 evaluators scored 4 videos of infants with type I SMA to assess interrater reliability. Intrarater and test-retest reliability was further assessed for 9 evaluators during a SMA type I clinical trial, with 9 evaluators testing a total of 38 infants twice. Relatedness of the TIMPSI score to ability to reach and ventilatory support was also examined. Results Excellent interrater video score reliability was noted (intraclass correlation coefficient, 0.97–0.98). Intrarater reliability was excellent (intraclass correlation coefficient, 0.91–0.98) and test-retest reliability ranged from r = 0.82 to r = 0.95. The TIMPSI score was related to the ability to reach (P ≤ .05). Conclusion The TIMPSI can reliably be used to assess motor function in infants with type I SMA. In addition, the TIMPSI scores are related to the ability to reach, an important functional skill in children with type I SMA. PMID:23542189

  18. Handling of computational in vitro/in vivo correlation problems by Microsoft Excel: V. Predictive absorbability models.

    PubMed

    Langenbucher, Frieder

    2007-08-01

    This paper discusses Excel applications related to the prediction of drug absorbability from physicochemical constants. PHDISSOC provides a generalized model for pH profiles of electrolytic dissociation, water solubility, and partition coefficient. SKMODEL predicts drug absorbability, based on a log-log plot of water solubility and O/W partitioning; augmented by additional features such as electrolytic dissociation, melting point, and the dose administered. GIABS presents a mechanistic model of g.i. drug absorption. BIODATCO presents a database compiling relevant drug data to be used for quantitative predictions.

  19. Handling of computational in vitro/in vivo correlation problems by Microsoft Excel: IV. Generalized matrix analysis of linear compartment systems.

    PubMed

    Langenbucher, Frieder

    2005-01-01

    A linear system comprising n compartments is completely defined by the rate constants between any of the compartments and the initial condition in which compartment(s) the drug is present at the beginning. The generalized solution is the time profiles of drug amount in each compartment, described by polyexponential equations. Based on standard matrix operations, an Excel worksheet computes the rate constants and the coefficients, finally the full time profiles for a specified range of time values.

  20. Validity and cross-cultural adaptation of the persian version of the oxford elbow score.

    PubMed

    Ebrahimzadeh, Mohammad H; Kachooei, Amir Reza; Vahedi, Ehsan; Moradi, Ali; Mashayekhi, Zeinab; Hallaj-Moghaddam, Mohammad; Azami, Mehran; Birjandinejad, Ali

    2014-01-01

    Oxford Elbow Score (OES) is a patient-reported questionnaire used to assess outcomes after elbow surgery. The aim of this study was to validate and adapt the OES into Persian language. After forward-backward translation of the OES into Persian, a total number of 92 patients after elbow surgeries completed the Persian OES along with the Persian DASH and SF-36. To assess test-retest reliability, 31 randomly selected patients (34%) completed the Persian OES again after three days while abstaining from all forms of therapeutic regimens. Reliability of the Persian OES was assessed by measuring intraclass correlation coefficient (ICC) for test-retest reliability and Cronbach's alpha for internal consistency. Spearman's correlation coefficient was used to test the construct validity. Cronbach's alpha coefficient was 0.92 showing excellent reliability. Cronbach's alpha for function, pain, and social-psychological subscales was 0.95, 0.86, and 0.85, respectively. Intraclass correlation coefficient (ICC) was 0.85 for the overall questionnaire and 0.90, 0.76, and 0.75 for function, pain, and social-psychological subscales, respectively. Construct validity was confirmed as the Spearman correlation between OES and DASH was 0.80. Persian OES is a valid and reliable patient-reported outcome measure to assess postsurgical elbow status in Persian speaking population.

  1. Strong correlation effects on surfaces of topological insulators via holography

    NASA Astrophysics Data System (ADS)

    Seo, Yunseok; Song, Geunho; Sin, Sang-Jin

    2017-07-01

    We investigate the effects of strong correlation on the surface state of a topological insulator (TI). We argue that electrons in the regime of crossover from weak antilocalization to weak localization are strongly correlated, and calculate the magnetotransport coefficients of TIs using the gauge-gravity principle. Then, we examine the magnetoconductivity (MC) formula and find excellent agreement with the data of chrome-doped Bi2Te3 in the crossover regime. We also find that the cusplike peak in MC at low doping is absent, which is natural since quasiparticles disappear due to the strong correlation.

  2. Linear Least Squares for Correlated Data

    NASA Technical Reports Server (NTRS)

    Dean, Edwin B.

    1988-01-01

    Throughout the literature authors have consistently discussed the suspicion that regression results were less than satisfactory when the independent variables were correlated. Camm, Gulledge, and Womer, and Womer and Marcotte provide excellent applied examples of these concerns. Many authors have obtained partial solutions for this problem as discussed by Womer and Marcotte and Wonnacott and Wonnacott, which result in generalized least squares algorithms to solve restrictive cases. This paper presents a simple but relatively general multivariate method for obtaining linear least squares coefficients which are free of the statistical distortion created by correlated independent variables.

  3. Repeatability of shear wave elastography in liver fibrosis phantoms—Evaluation of five different systems

    PubMed Central

    2018-01-01

    This study aimed to assess and validate the repeatability and agreement of quantitative elastography of novel shear wave methods on four individual tissue-mimicking liver fibrosis phantoms with different known Young’s modulus. We used GE Logiq E9 2D-SWE, Philips iU22 ARFI (pSWE), Samsung TS80A SWE (pSWE), Hitachi Ascendus (SWM) and Transient Elastography (TE). Two individual investigators performed all measurements non-continued and in parallel. The methods were evaluated for inter- and intraobserver variability by intraclass correlation, coefficient of variation and limits of agreement using the median elastography value. All systems used in this study provided high repeatability in quantitative measurements in a liver fibrosis phantom and excellent inter- and intraclass correlations. All four elastography platforms showed excellent intra-and interobserver agreement (interclass correlation 0.981–1.000 and intraclass correlation 0.987–1.000) and no significant difference in mean elasticity measurements for all systems, except for TE on phantom 4. All four liver fibrosis phantoms could be differentiated by quantitative elastography, by all platforms (p<0.001). In the Bland-Altman analysis the differences in measurements were larger for the phantoms with higher Young’s modulus. All platforms had a coefficient of variation in the range 0.00–0.21 for all four phantoms, equivalent to low variance and high repeatability. PMID:29293527

  4. Psychometric properties and cross-cultural adaptation of the Brazilian Quebec back pain disability scale questionnaire.

    PubMed

    Rodrigues, Marcelo F; Michel-Crosato, Edgard; Cardoso, Jefferson R; Traebert, Jefferson

    2009-06-01

    Cross-cultural translation and psychometric testing. To translate and cross-culturally adapt the Quebec Back Pain Disability Scale (QDS) to Brazilian Portuguese and to examine its validity and reliability. Current literature shows the need to adopt reliable and internationally standardized methods for the analysis of low back pain. To our knowledge, this specific questionnaire has not been translated and validated for Portuguese-speaking patients. The translation and cross-cultural adaptation of the QDS were developed in agreement with internationally recommended methodology, and the resulting product was evaluated in this study with 54 consecutive patients. Internal consistency was obtained through Cronbach's alpha; reliability was estimated through the intraclass correlation coefficient and the Bland and Altman agreement (d = mean difference). Validity was determined by correlating the scores of the Brazil-QDS with the Brazilian version of the Roland-Morris Questionnaire and Visual Analogue Pain Scale by means of the Spearman rank correlation coefficient. The internal consistency obtained was excellent (Cronbach's alpha = 0.97). Intraobserver and interobserver reliability were considered strong (ICC = 0.93-d = 0.68 and 0.96-d = 0.57, respectively). The correlation with Brazilian Roland-Morris Questionnaire and with the Visual Analogue Scale was high (r = 0.857; r = 0.758, respectively). The data showed that the process of translation and cross-cultural adaptation were successful and that the adapted instrument demonstrated excellent psychometric properties.

  5. Overcoming multicollinearity in multiple regression using correlation coefficient

    NASA Astrophysics Data System (ADS)

    Zainodin, H. J.; Yap, S. J.

    2013-09-01

    Multicollinearity happens when there are high correlations among independent variables. In this case, it would be difficult to distinguish between the contributions of these independent variables to that of the dependent variable as they may compete to explain much of the similar variance. Besides, the problem of multicollinearity also violates the assumption of multiple regression: that there is no collinearity among the possible independent variables. Thus, an alternative approach is introduced in overcoming the multicollinearity problem in achieving a well represented model eventually. This approach is accomplished by removing the multicollinearity source variables on the basis of the correlation coefficient values based on full correlation matrix. Using the full correlation matrix can facilitate the implementation of Excel function in removing the multicollinearity source variables. It is found that this procedure is easier and time-saving especially when dealing with greater number of independent variables in a model and a large number of all possible models. Hence, in this paper detailed insight of the procedure is shown, compared and implemented.

  6. Monte Carlo simulation of parameter confidence intervals for non-linear regression analysis of biological data using Microsoft Excel.

    PubMed

    Lambert, Ronald J W; Mytilinaios, Ioannis; Maitland, Luke; Brown, Angus M

    2012-08-01

    This study describes a method to obtain parameter confidence intervals from the fitting of non-linear functions to experimental data, using the SOLVER and Analysis ToolPaK Add-In of the Microsoft Excel spreadsheet. Previously we have shown that Excel can fit complex multiple functions to biological data, obtaining values equivalent to those returned by more specialized statistical or mathematical software. However, a disadvantage of using the Excel method was the inability to return confidence intervals for the computed parameters or the correlations between them. Using a simple Monte-Carlo procedure within the Excel spreadsheet (without recourse to programming), SOLVER can provide parameter estimates (up to 200 at a time) for multiple 'virtual' data sets, from which the required confidence intervals and correlation coefficients can be obtained. The general utility of the method is exemplified by applying it to the analysis of the growth of Listeria monocytogenes, the growth inhibition of Pseudomonas aeruginosa by chlorhexidine and the further analysis of the electrophysiological data from the compound action potential of the rodent optic nerve. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  7. Cross-cultural adaptation, reliability, and validity of the Turkish version of PedsQL 3.0 Arthritis Module: a quality-of-life measure for patients with juvenile idiopathic arthritis in Turkey.

    PubMed

    Tarakci, E; Baydogan, S N; Kasapcopur, O; Dirican, A

    2013-04-01

    The aim of this study was to describe the cultural adaptation, validity, and reliability of a Turkish version of the pediatric quality-of-life inventory (PedsQL) 3.0 Arthritis Module in a population with juvenile idiopathic arthritis (JIA). A total of 169 patients with JIA and their parents were enrolled in the study. The Turkish version of the childhood health assessment questionnaire (CHAQ) was used to evaluate the validity of related domains in the PedsQL 3.0 Arthritis Module. Both the PedsQL 3.0 Arthritis Module and CHAQ were filled out by children over 8 years of age and by the parents of children 2-7 years of age. Internal reliability was poor to excellent (Cronbach's alpha coefficients 0.56-0.84 for self-reporting and 0.63-0.82 for parent reporting), and interobserver reliability varied from good to excellent (intraclass correlation coefficient (ICC) 0.79-0.91 for self-reporting and 0.80-0.88 for parent reporting) for the total scores of the PedsQL 3.0 Arthritis Module. Parent-child concordance for all scores was moderate to excellent (ICC 0.42-0.92). The PedsQL 3.0 Arthritis Module and CHAQ were highly positively correlated, with coefficients from 0.21 to 0.76, indicating concurrent validity. We demonstrated the reliability and validity of quality-of-life measurement using the Turkish version of the PedsQL 3.0 Arthritis Module in our sociocultural context. The PedsQL 3.0 Arthritis Module can be utilized as a tool for the evaluation of quality of life in patients with JIA aged 2-18 years.

  8. Correlation between mass transfer coefficient kLa and relevant operating parameters in cylindrical disposable shaken bioreactors on a bench-to-pilot scale

    PubMed Central

    2013-01-01

    Background Among disposable bioreactor systems, cylindrical orbitally shaken bioreactors show important advantages. They provide a well-defined hydrodynamic flow combined with excellent mixing and oxygen transfer for mammalian and plant cell cultivations. Since there is no known universal correlation between the volumetric mass transfer coefficient for oxygen kLa and relevant operating parameters in such bioreactor systems, the aim of this current study is to experimentally determine a universal kLa correlation. Results A Respiration Activity Monitoring System (RAMOS) was used to measure kLa values in cylindrical disposable shaken bioreactors and Buckingham’s π-Theorem was applied to define a dimensionless equation for kLa. In this way, a scale- and volume-independent kLa correlation was developed and validated in bioreactors with volumes from 2 L to 200 L. The final correlation was used to calculate cultivation parameters at different scales to allow a sufficient oxygen supply of tobacco BY-2 cell suspension cultures. Conclusion The resulting equation can be universally applied to calculate the mass transfer coefficient for any of seven relevant cultivation parameters such as the reactor diameter, the shaking frequency, the filling volume, the viscosity, the oxygen diffusion coefficient, the gravitational acceleration or the shaking diameter within an accuracy range of +/− 30%. To our knowledge, this is the first kLa correlation that has been defined and validated for the cited bioreactor system on a bench-to-pilot scale. PMID:24289110

  9. Correlation between mass transfer coefficient kLa and relevant operating parameters in cylindrical disposable shaken bioreactors on a bench-to-pilot scale.

    PubMed

    Klöckner, Wolf; Gacem, Riad; Anderlei, Tibor; Raven, Nicole; Schillberg, Stefan; Lattermann, Clemens; Büchs, Jochen

    2013-12-02

    Among disposable bioreactor systems, cylindrical orbitally shaken bioreactors show important advantages. They provide a well-defined hydrodynamic flow combined with excellent mixing and oxygen transfer for mammalian and plant cell cultivations. Since there is no known universal correlation between the volumetric mass transfer coefficient for oxygen kLa and relevant operating parameters in such bioreactor systems, the aim of this current study is to experimentally determine a universal kLa correlation. A Respiration Activity Monitoring System (RAMOS) was used to measure kLa values in cylindrical disposable shaken bioreactors and Buckingham's π-Theorem was applied to define a dimensionless equation for kLa. In this way, a scale- and volume-independent kLa correlation was developed and validated in bioreactors with volumes from 2 L to 200 L. The final correlation was used to calculate cultivation parameters at different scales to allow a sufficient oxygen supply of tobacco BY-2 cell suspension cultures. The resulting equation can be universally applied to calculate the mass transfer coefficient for any of seven relevant cultivation parameters such as the reactor diameter, the shaking frequency, the filling volume, the viscosity, the oxygen diffusion coefficient, the gravitational acceleration or the shaking diameter within an accuracy range of +/- 30%. To our knowledge, this is the first kLa correlation that has been defined and validated for the cited bioreactor system on a bench-to-pilot scale.

  10. Refinement of the Interprofessional Socialization and Valuing Scale (ISVS-21) and Development of 9-Item Equivalent Versions.

    PubMed

    King, Gillian; Orchard, Carole; Khalili, Hossein; Avery, Lisa

    2016-01-01

    Measures of interprofessional (IP) socialization are needed to capture the role of interprofessional education in preparing students and health practitioners to function as part of IP health care teams. The aims of this study were to refine a previously published version of the Interprofessional Socialization and Valuing Scale (the ISVS-24) and create two shorter equivalent forms to be used in pre-post studies. A graded response model was used to identify ISVS items in a practitioner data set (n = 345), with validation (measure invariance) conducted using a separate student sample (n = 341). Analyses indicated a unidimensional 21-item version with excellent measurement properties, Cronbach alpha of 0.988, 95% confidence interval (CI) 0.985-0.991. There was evidence of measure invariance, as there was excellent agreement of the factor scores for the practitioner and student data, intraclass correlation coefficient = 0.993, 95% CI 0.991-0.994. This indicates that the ISVS-21 measures IP socialization consistently across groups. Two 9-item equivalent versions for pre-post use were developed, with excellent agreement between the two forms. The student score agreement for the two item sets was excellent: intraclass correlation coefficient = 0.970, 95% CI 0.963-0.976. The ISVS-21 is a refined measure to assess existing levels of IP socialization in practitioners and students, and relate IP socialization to other important constructs such as IP collaboration and the development of an IP identity. The equivalent versions can be used to assess change in IP socialization as a result of interprofessional education.

  11. Cross-cultural adaptation and validation of the Saudi Arabic version of the Knee Injury and Osteoarthritis Outcome Score (KOOS).

    PubMed

    Alfadhel, Saud A; Vennu, Vishal; Alnahdi, Ali H; Omar, Mohammed T; Alasmari, Saeed H; AlJafri, Zahra; Bindawas, Saad M

    2018-06-07

    The Knee Injury Osteoarthritis Outcome Score (KOOS) is a widely used joint-specific measure employed to evaluate pain, symptoms, activities of daily living, recreational activities, and quality of life in patients with knee osteoarthritis (OA). Although the original KOOS has been translated into many languages, a Saudi Arabic version is not available. This study aimed to culturally adapt and evaluate the psychometric properties of the Saudi Arabic version of the KOOS in patients with knee OA. The original KOOS was translated and adapted into Saudi Arabic version over six stages according to the guidelines suggested by Beaton and recommended by the American Association of Orthopedic Surgeons Outcome Committee. Patients diagnosed with knee OA (n = 136) were recruited to examine the psychometric properties, such as internal consistency that was tested using Cronbach's alpha, test-retest reliability that was analyzed using the intra-class correlation coefficient (ICC 2,1 ), and construct validity that examined by testing the correlations between the new version subscales, Form 36 Health Survey subscales, and the Visual Analog Scale, Spearman's correlation coefficient (r s ) was used to measure the correlations. A total of 122 (89.7%) of the 136 participants with knee OA completed the second re-test of new Saudi Arabic version. Excellent internal consistency (Cronbach's alpha = 0.87-0.92) was detected in the subscales of the adapted version, as well as excellent test-retest reliability (ICC 2,1  = 0.92-0.94). The pattern of correlation between the subscales of the Saudi Arabic version of the KOOS, SF-36 domains and the Visual Analog Scale for pain supported the construct validity of the adapted version. The Saudi Arabic version of the KOOS was well accepted and exhibited excellent reliability, internal consistency, and construct validity in Saudi patients with knee OA.

  12. p-capture reaction cycles in rotating massive stars and their impact on elemental abundances in globular cluster stars: A case study of O, Na and Al

    NASA Astrophysics Data System (ADS)

    Mahanta, Upakul; Goswami, Aruna; Duorah, Hiralal; Duorah, Kalpana

    2017-08-01

    Elemental abundance patterns of globular cluster stars can provide important clues for understanding cluster formation and early chemical evolution. The origin of the abundance patterns, however, still remains poorly understood. We have studied the impact of p-capture reaction cycles on the abundances of oxygen, sodium and aluminium considering nuclear reaction cycles of carbon-nitrogen-oxygen-fluorine, neon-sodium and magnesium-aluminium in massive stars in stellar conditions of temperature range 2×107 to 10×107 K and typical density of 102 gm cc-1. We have estimated abundances of oxygen, sodium and aluminium with respect to Fe, which are then assumed to be ejected from those stars because of rotation reaching a critical limit. These ejected abundances of elements are then compared with their counterparts that have been observed in some metal-poor evolved stars, mainly giants and red giants, of globular clusters M3, M4, M13 and NGC 6752. We observe an excellent agreement with [O/Fe] between the estimated and observed abundance values for globular clusters M3 and M4 with a correlation coefficient above 0.9 and a strong linear correlation for the remaining two clusters with a correlation coefficient above 0.7. The estimated [Na/Fe] is found to have a correlation coefficient above 0.7, thus implying a strong correlation for all four globular clusters. As far as [Al/Fe] is concerned, it also shows a strong correlation between the estimated abundance and the observed abundance for globular clusters M13 and NGC 6752, since here also the correlation coefficient is above 0.7 whereas for globular cluster M4 there is a moderate correlation found with a correlation coefficient above 0.6. Possible sources of these discrepancies are discussed.

  13. Validity and reliability of a new tool to evaluate handwriting difficulties in Parkinson's disease.

    PubMed

    Nackaerts, Evelien; Heremans, Elke; Smits-Engelsman, Bouwien C M; Broeder, Sanne; Vandenberghe, Wim; Bergmans, Bruno; Nieuwboer, Alice

    2017-01-01

    Handwriting in Parkinson's disease (PD) features specific abnormalities which are difficult to assess in clinical practice since no specific tool for evaluation of spontaneous movement is currently available. This study aims to validate the 'Systematic Screening of Handwriting Difficulties' (SOS-test) in patients with PD. Handwriting performance of 87 patients and 26 healthy age-matched controls was examined using the SOS-test. Sixty-seven patients were tested a second time within a period of one month. Participants were asked to copy as much as possible of a text within 5 minutes with the instruction to write as neatly and quickly as in daily life. Writing speed (letters in 5 minutes), size (mm) and quality of handwriting were compared. Correlation analysis was performed between SOS outcomes and other fine motor skill measurements and disease characteristics. Intrarater, interrater and test-retest reliability were assessed using the intraclass correlation coefficient (ICC) and Spearman correlation coefficient. Patients with PD had a smaller (p = 0.043) and slower (p<0.001) handwriting and showed worse writing quality (p = 0.031) compared to controls. The outcomes of the SOS-test significantly correlated with fine motor skill performance and disease duration and severity. Furthermore, the test showed excellent intrarater, interrater and test-retest reliability (ICC > 0.769 for both groups). The SOS-test is a short and effective tool to detect handwriting problems in PD with excellent reliability. It can therefore be recommended as a clinical instrument for standardized screening of handwriting deficits in PD.

  14. Validation of the Balance Board for Clinical Evaluation of Balance During Serious Gaming Rehabilitation Exercises.

    PubMed

    Bonnechère, Bruno; Jansen, Bart; Omelina, Lubos; Sholukha, Victor; Van Sint Jan, Serge

    2016-09-01

    Balance and posture can be affected in various conditions or become decreased with aging. A diminution of balance control induces an increase of fall's risk. The Nintendo Wii Balance Board™ (WBB) is used in rehabilitation to perform balance exercises (using commercial video games). The WBB has also been validated to assess balance and posture in static conditions. However, there is currently no study investigating the use of WBB to assess balance during the realization of balance exercises using this device. The aim of this study was to validate the use of WBB, coupled with specially developed serious games, to assess dynamic balance during rehabilitation exercises. Thirty five subjects participated in this study. Subjects were asked to play two specially developed serious games. Center of pressure (CP) displacements were simultaneously recorded with a WBB and a gold standard force plate (FP). Nine parameters were derived from CP displacement. Bland and Altman plots, paired-sample t tests, intraclass correlation coefficient's, and Pearson's coefficient correlations were computed. Excellent correlation between both devices was found for each parameter for the two games (R = 0.95 and 0.96). Unlike previous work on the WBB, these excellent results were obtained without using any calibration procedure. Despite this, results were highly correlated between the WBB and the FP. The WBB could be used in clinics to assess balance during rehabilitation exercises and, thus, allows a more regular patient follow-up.

  15. Repeatability, interocular correlation and agreement of quantitative swept-source optical coherence tomography angiography macular metrics in healthy subjects.

    PubMed

    Fang, Danqi; Tang, Fang Yao; Huang, Haifan; Cheung, Carol Y; Chen, Haoyu

    2018-05-29

    To investigate the repeatability, interocular correlation and agreement of quantitative swept-source optical coherence tomography angiography (SS-OCTA) metrics in healthy subjects. Thirty-three healthy normal subjects were enrolled. The macula was scanned four times by an SS-OCTA system using the 3 mm×3 mm mode. The superficial capillary map images were analysed using a MATLAB program. A series of parameters were measured: foveal avascular zone (FAZ) area, FAZ perimeter, FAZ circularity, parafoveal vessel density, fractal dimension and vessel diameter index (VDI). The repeatability of four scans was determined by intraclass correlation coefficient (ICC). Then the averaged results were analysed for intereye difference, correlation and agreement using paired t-test, Pearson's correlation coefficient (r), ICC and Bland-Altman plot. The repeatability assessment of the macular metrics exported high ICC values (ranged from 0.853 to 0.996). There is no statistically significant difference in the OCTA metrics between the two eyes. FAZ area (ICC=0.961, r=0.929) and FAZ perimeter (ICC=0.884, r=0.802) showed excellent binocular correlation. Fractal dimension (ICC=0.732, r=0.578) and VDI (ICC=0.707, r=0.547) showed moderate binocular correlation, while parafoveal vessel density had poor binocular correlation. Bland-Altman plots showed the range of agreement was from -0.0763 to 0.0954 mm 2 for FAZ area and from -0.0491 to 0.1136 for parafoveal vessel density. The macular metrics obtained using SS-OCTA showed excellent repeatability in healthy subjects. We showed high intereye correlation in FAZ area and perimeter, moderate correlation in fractal dimension and VDI, while vessel density had poor correlation in normal healthy subjects. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. The Association Between Self-Rated Fitness and Cardiorespiratory Fitness in Adults.

    PubMed

    Jensen, Karina Gregersen; Rosthøj, Susanne; Linneberg, Allan; Aadahl, Mette

    2018-06-01

    To assess criterion validity of a single item question on self-rated physical fitness against objectively measured cardiorespiratory fitness. From the Health2008 study 749 men and women between 30 and 60 years of age rated their fitness as excellent, very good, good, fair or poor. Cardiorespiratory fitness was estimated with the watt-max test. Agreement between self-rated and objectively measured physical fitness was assessed by Cohen's weighted kappa coefficient. Correlation was determined by Goodman & Kruskal's gamma correlation coefficient. All analyses were stratified according to gender. Data from 323 men and 426 women were analysed. There was a slight agreement between self-rated and objectively measured fitness in men (weighted kappa: 0.18, [95%CI: 0.13;0.23]) and a fair agreement in women (weighted kappa: 0.27, [95%CI: 0.22;0.32]). In both genders, self-rated fitness was positively correlated with objectively measured fitness (moderate correlation; gamma correlation coefficient for men: 0.63 [95%CI: 0.54;0.72] and women: 0.67 [95%CI: 0.59;0.75]). There was a slight to fair agreement and moderate, positive correlations between self-rated physical fitness and watt-max estimated cardiorespiratory fitness. Hence, a single-item question on physical fitness may be a cost-effective method of assessing fitness in large population studies, but is not valid for individual assessments. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Reliability study of tibialis posterior and selected leg muscle EMG and multi-segment foot kinematics in rheumatoid arthritis associated pes planovalgus

    PubMed Central

    Barn, Ruth; Rafferty, Daniel; Turner, Deborah E.; Woodburn, James

    2012-01-01

    Objective To determine within- and between-day reliability characteristics of electromyographic (EMG) activity patterns of selected lower leg muscles and kinematic variables in patients with rheumatoid arthritis (RA) and pes planovalgus. Methods Five patients with RA underwent gait analysis barefoot and shod on two occasions 1 week apart. Fine-wire (tibialis posterior [TP]) and surface EMG for selected muscles and 3D kinematics using a multi-segmented foot model was undertaken barefoot and shod. Reliability of pre-determined variables including EMG activity patterns and inter-segment kinematics were analysed using coefficients of multiple correlation, intraclass correlation coefficients (ICC) and the standard error of the measurement (SEM). Results Muscle activation patterns within- and between-day ranged from fair-to-good to excellent in both conditions. Discrete temporal and amplitude variables were highly variable across all muscle groups in both conditions but particularly poor for TP and peroneus longus. SEMs ranged from 1% to 9% of stance and 4% to 27% of maximum voluntary contraction; in most cases the 95% confidence interval crossed zero. Excellent within-day reliability was found for the inter-segment kinematics in both conditions. Between-day reliability ranged from fair-to-good to excellent for kinematic variables and all ICCs were excellent; the SEM ranged from 0.60° to 1.99°. Conclusion Multi-segmented foot kinematics can be reliably measured in RA patients with pes planovalgus. Serial measurement of discrete variables for TP and other selected leg muscles via EMG is not supported from the findings in this cohort of RA patients. Caution should be exercised when EMG measurements are considered to study disease progression or intervention effects. PMID:22721819

  18. [Reliability and external validity of a questionnaire to assess the knowledge about risk and cardiovascular disease and in patients attending Spanish community pharmacies].

    PubMed

    Amariles, Pedro; Pino-Marín, Daniel; Sabater-Hernández, Daniel; García-Jiménez, Emilio; Roig-Sánchez, Inés; Faus, María José

    2016-11-01

    To determine the test-retest reliability of a questionnaire, with a validation preliminary, to assess knowledge of cardiovascular risk (CVR) and cardiovascular disease in patients attending community pharmacies in Spain. To complement the external validity, establishing the relationship between an educational activity and the increase in knowledge about CVR and cardiovascular disease. Sub-analysis of a controlled clinical study, EMDADER-CV, in which a questionnaire about knowledge concerning CVR was applied at 4 different times. Spanish Community Pharmacies. There were 323 patients in the control group, from the 640 who completed the study. Intraclass correlation coefficient to assess the reliability in 3 comparisons (post-educational activity with week 16, post-educational activity with week 32, and week 16 with week 32); and the non-parametric Friedman test to establish the relationship between an oral and written educational activity with increasing knowledge. For the 323 patients in the 3 comparisons, the intraclass correlation coefficient values were 0.624; 0.608 and 0.801, respectively (fair-good to excellent reliability). So, the Friedman test showed a statistically significant relationship between educational activity and increased knowledge (p < .0001). According to the intraclass correlation coefficient, the questionnaire aimed at assessing the knowledge on CVR and cardiovascular disease has a reliability between acceptable and excellent, which added to the previous validation, shows that the instrument meets the criteria of validity and reliability. Furthermore, the questionnaire showed the ability to relate an increase in knowledge with an educational intervention, feature that complements its external validity. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  19. Instrument validation process: a case study using the Paediatric Pain Knowledge and Attitudes Questionnaire.

    PubMed

    Peirce, Deborah; Brown, Janie; Corkish, Victoria; Lane, Marguerite; Wilson, Sally

    2016-06-01

    To compare two methods of calculating interrater agreement while determining content validity of the Paediatric Pain Knowledge and Attitudes Questionnaire for use with Australian nurses. Paediatric pain assessment and management documentation was found to be suboptimal revealing a need to assess paediatric nurses' knowledge and attitude to pain. The Paediatric Pain Knowledge and Attitudes Questionnaire was selected as it had been reported as valid and reliable in the United Kingdom with student nurses. The questionnaire required content validity determination prior to use in the Australian context. A two phase process of expert review. Ten paediatric nurses completed a relevancy rating of all 68 questionnaire items. In phase two, five pain experts reviewed the items of the questionnaire that scored an unacceptable item level content validity. Item and scale level content validity indices and intraclass correlation coefficients were calculated. In phase one, 31 items received an item level content validity index <0·78 and the scale level content validity index average was 0·80 which were below levels required for acceptable validity. The intraclass correlation coefficient was 0·47. In phase two, 10 items were amended and four items deleted. The revised questionnaire provided a scale level content validity index average >0·90 and an intraclass correlation coefficient of 0·94 demonstrating excellent agreement between raters therefore acceptable content validity. Equivalent outcomes were achieved using the content validity index and the intraclass correlation coefficient. To assess content validity the content validity index has the advantage of providing an item level score and is a simple calculation. The intraclass correlation coefficient requires statistical knowledge, or support, and has the advantage of accounting for the possibility of chance agreement. © 2016 John Wiley & Sons Ltd.

  20. Use of the Liverpool Elbow Score as a postal questionnaire for the assessment of outcome after total elbow arthroplasty.

    PubMed

    Ashmore, Alexander M; Gozzard, Charles; Blewitt, Neil

    2007-01-01

    The Liverpool Elbow Score (LES) is a newly developed, validated elbow-specific score. It consists of a patient-answered questionnaire (PAQ) and a clinical assessment. The purpose of this study was to determine whether the PAQ portion of the LES could be used independently as a postal questionnaire for the assessment of outcome after total elbow arthroplasty and to correlate the LES and the Mayo Elbow Performance Score (MEPS). A series of 51 total elbow replacements were reviewed by postal questionnaire. Patients then attended the clinic for assessment by use of both the LES and the MEPS. There was an excellent response rate to the postal questionnaire (98%), and 44 elbows were available for clinical review. Good correlation was shown between the LES and the MEPS (Spearman correlation coefficient, 0.84; P < .001) and between the PAQ portion of the LES and the MEPS (Spearman correlation coefficient, 0.76; P < .001). We conclude that there is good correlation between the LES PAQ component and the MEPS, suggesting that outcome assessment is possible by postal questionnaire.

  1. Development of a Microsoft Excel tool for applying a factor retention criterion of a dimension coefficient to a survey on patient safety culture.

    PubMed

    Chien, Tsair-Wei; Shao, Yang; Jen, Dong-Hui

    2017-10-27

    Many quality-of-life studies have been conducted in healthcare settings, but few have used Microsoft Excel to incorporate Cronbach's α with dimension coefficient (DC) for describing a scale's characteristics. To present a computer module that can report a scale's validity, we manipulated datasets to verify a DC that can be used as a factor retention criterion for demonstrating its usefulness in a patient safety culture survey (PSC). Microsoft Excel Visual Basic for Applications was used to design a computer module for simulating 2000 datasets fitting the Rasch rating scale model. The datasets consisted of (i) five dual correlation coefficients (correl. = 0.3, 0.5, 0.7, 0.9, and 1.0) on two latent traits (i.e., true scores) following a normal distribution and responses to their respective 1/3 and 2/3 items in length; (ii) 20 scenarios of item lengths from 5 to 100; and (iii) 20 sample sizes from 50 to 1000. Each item containing 5-point polytomous responses was uniformly distributed in difficulty across a ± 2 logit range. Three methods (i.e., dimension interrelation ≥0.7, Horn's parallel analysis (PA) 95% confidence interval, and individual random eigenvalues) were used for determining one factor to retain. DC refers to the binary classification (1 as one factor and 0 as many factors) used for examining accuracy with the indicators sensitivity, specificity, and area under receiver operating characteristic curve (AUC). The scale's reliability and DC were simultaneously calculated for each simulative dataset. PSC real data were demonstrated with DC to interpret reports of the unit-based construct validity using the author-made MS Excel module. The DC method presented accurate sensitivity (=0.96), specificity (=0.92) with a DC criterion (≥0.70), and AUC (=0.98) that were higher than those of the two PA methods. PA combined with DC yielded good sensitivity (=0.96), specificity (=1.0) with a DC criterion (≥0.70), and AUC (=0.99). Advances in computer technology may enable healthcare users familiar with MS Excel to apply DC as a factor retention criterion for determining a scale's unidimensionality and evaluating a scale's quality.

  2. Mobile detection system to evaluate reactive hyperemia using radionuclide plethysmography.

    PubMed

    Harel, François; Ngo, Quam; Finnerty, Vincent; Hernandez, Edgar; Khairy, Paul; Dupuis, Jocelyn

    2007-08-01

    We validated a novel mobile detection system to evaluate reactive hyperemia using the radionuclide plethysmography technique. Twenty-six subjects underwent simultaneously radionuclide plethysmography with strain gauge plethysmography. Strain gauge and radionuclide methods showed excellent reproducibility with intraclass correlation coefficients of 0.96 and 0.89 respectively. There was also a good correlation of flows between the two methods during reactive hyperemia (r = 0.87). We conclude that radionuclide plethysmography using this mobile detection system is a non-invasive alternative to assess forearm blood flow and its dynamic variations during reactive hyperemia.

  3. Modified free volume theory of self-diffusion and molecular theory of shear viscosity of liquid carbon dioxide.

    PubMed

    Nasrabad, Afshin Eskandari; Laghaei, Rozita; Eu, Byung Chan

    2005-04-28

    In previous work on the density fluctuation theory of transport coefficients of liquids, it was necessary to use empirical self-diffusion coefficients to calculate the transport coefficients (e.g., shear viscosity of carbon dioxide). In this work, the necessity of empirical input of the self-diffusion coefficients in the calculation of shear viscosity is removed, and the theory is thus made a self-contained molecular theory of transport coefficients of liquids, albeit it contains an empirical parameter in the subcritical regime. The required self-diffusion coefficients of liquid carbon dioxide are calculated by using the modified free volume theory for which the generic van der Waals equation of state and Monte Carlo simulations are combined to accurately compute the mean free volume by means of statistical mechanics. They have been computed as a function of density along four different isotherms and isobars. A Lennard-Jones site-site interaction potential was used to model the molecular carbon dioxide interaction. The density and temperature dependence of the theoretical self-diffusion coefficients are shown to be in excellent agreement with experimental data when the minimum critical free volume is identified with the molecular volume. The self-diffusion coefficients thus computed are then used to compute the density and temperature dependence of the shear viscosity of liquid carbon dioxide by employing the density fluctuation theory formula for shear viscosity as reported in an earlier paper (J. Chem. Phys. 2000, 112, 7118). The theoretical shear viscosity is shown to be robust and yields excellent density and temperature dependence for carbon dioxide. The pair correlation function appearing in the theory has been computed by Monte Carlo simulations.

  4. Trunk Muscle Size and Composition Assessment in Older Adults with Chronic Low Back Pain: An Intra-Examiner and Inter-Examiner Reliability Study.

    PubMed

    Sions, Jaclyn Megan; Smith, Andrew Craig; Hicks, Gregory Evan; Elliott, James Matthew

    2016-08-01

    To evaluate intra- and inter-examiner reliability for the assessment of relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area, i.e., total cross-sectional area minus intramuscular fat, from T1-weighted magnetic resonance images obtained in older adults with chronic low back pain. Reliability study. n = 13 (69.3 ± 8.2 years old) After lumbar magnetic resonance imaging, two examiners produced relative cross-sectional area measurements of multifidi, erector spinae, psoas, and quadratus lumborum by tracing regions of interest just inside fascial borders. Pixel-intensity summaries were used to determine muscle-to-fat infiltration indices; relative muscle cross-sectional area was calculated. Intraclass correlation coefficients were used to estimate intra- and inter-examiner reliability; standard error of measurement was calculated. Intra-examiner intraclass correlation coefficient point estimates for relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area were excellent for multifidi and erector spinae across levels L2-L5 (ICC = 0.77-0.99). At L3, intra-examiner reliability was excellent for relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area for both psoas and quadratus lumborum (ICC = 0.81-0.99). Inter-examiner intraclass correlation coefficients ranged from poor to excellent for relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area. Assessment of relative cross-sectional area, muscle-to-fat infiltration indices, and relative muscle cross-sectional area in older adults with chronic low back pain can be reliably determined by one examiner from T1-weighted images. Such assessments provide valuable information, as muscle-to-fat infiltration indices and relative muscle cross-sectional area indicate that a substantial amount of relative cross-sectional area may be magnetic resonance-visible intramuscular fat in older adults with chronic low back pain. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. The Scarbase Duo(®): Intra-rater and inter-rater reliability and validity of a compact dual scar assessment tool.

    PubMed

    Fell, Matthew; Meirte, Jill; Anthonissen, Mieke; Maertens, Koen; Pleat, Jonathon; Moortgat, Peter

    2016-03-01

    Objective scar assessment tools were designed to help identify problematic scars and direct clinical management. Their use has been restricted by their measurement of a single scar property and the bulky size of equipment. The Scarbase Duo(®) was designed to assess both trans-epidermal water loss (TEWL) and colour of a burn scar whilst being compact and easy to use. Twenty patients with a burn scar were recruited and measurements taken using the Scarbase Duo(®) by two observers. The Scarbase Duo(®) measures TEWL via an open-chamber system and undertakes colorimetry via narrow-band spectrophotometry, producing values for relative erythema and melanin pigmentation. Validity was assessed by comparing the Scarbase Duo(®) against the Dermalab(®) and the Minolta Chromameter(®) respectively for TEWL and colorimetry measurements. The intra-class correlation coefficient (ICC) was used to assess reliability with standard error of measurement (SEM) used to assess reproducibility of measurements. The Pearson correlation coefficient (r) was used to assess the convergent validity. The Scarbase Duo(®) TEWL mode had excellent reliability when used on scars for both intra- (ICC=0.95) and inter-rater (ICC=0.96) measurements with moderate SEM values. The erythema component of the colorimetry mode showed good reliability for use on scars for both intra-(ICC=0.81) and inter-rater (ICC=0.83) measurements with low SEM values. Pigmentation values showed excellent reliability on scar tissue for both intra- (ICC=0.97) and inter-rater (ICC=0.97) with moderate SEM values. The Scarbase Duo(®) TEWL function had excellent correlation with the Dermalab(®) (r=0.93) whilst the colorimetry erythema value had moderate correlation with the Minolta Chromameter (r=0.72). The Scarbase Duo(®) is a reliable and objective scar assessment tool, which is specifically designed for burn scars. However, for clinical use, standardised measurement conditions are recommended. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.

  6. Accuracy of contrast-enhanced spectral mammography for estimating residual tumor size after neoadjuvant chemotherapy in patients with breast cancer: a feasibility study.

    PubMed

    Barra, Filipe Ramos; de Souza, Fernanda Freire; Camelo, Rosimara Eva Ferreira Almeida; Ribeiro, Andrea Campos de Oliveira; Farage, Luciano

    2017-01-01

    To assess the feasibility of contrast-enhanced spectral mammography (CESM) of the breast for assessing the size of residual tumors after neoadjuvant chemotherapy (NAC). In breast cancer patients who underwent NAC between 2011 and 2013, we evaluated residual tumor measurements obtained with CESM and full-field digital mammography (FFDM). We determined the concordance between the methods, as well as their level of agreement with the pathology. Three radiologists analyzed eight CESM and FFDM measurements separately, considering the size of the residual tumor at its largest diameter and correlating it with that determined in the pathological analysis. Interobserver agreement was also evaluated. The sensitivity, specificity, positive predictive value, and negative predictive value were higher for CESM than for FFDM (83.33%, 100%, 100%, and 66% vs. 50%, 50%, 50%, and 25%, respectively). The CESM measurements showed a strong, consistent correlation with the pathological findings (correlation coefficient = 0.76-0.92; intraclass correlation coefficient = 0.692-0.886). The correlation between the FFDM measurements and the pathological findings was not statistically significant, with questionable consistency (intraclass correlation coefficient = 0.488-0.598). Agreement with the pathological findings was narrower for CESM measurements than for FFDM measurements. Interobserver agreement was higher for CESM than for FFDM (0.94 vs. 0.88). CESM is a feasible means of evaluating residual tumor size after NAC, showing a good correlation and good agreement with pathological findings. For CESM measurements, the interobserver agreement was excellent.

  7. Development of a valid Simplified Chinese version of the International Hip Outcome Tool (SC-iHOT-33) in young patients having total hip arthroplasty.

    PubMed

    Li, D H; Wang, W; Li, X; Gao, Y L; Liu, D H; Liu, D L; Xu, W D

    2017-01-01

    The International Hip Outcome Tool (iHOT-33) is a questionnaire designed for young, active patients with hip disorders. It has proven to be a highly reliable and valid questionnaire. The main purpose of our study was to adapt the iHOT-33 questionnaire into simplified Chinese and to assess its psychometric properties in Chinese patients. The iHOT-33 was cross culturally adapted into Chinese and 138 patients completed the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the EuroQol-5D (EQ-5D), and the Chinese version of the iHOT-33(SC-iHOT-33) pre- or postoperatively within 6 months' follow-up. The Cronbach's alpha, intraclass correlation coefficient (ICC), Pearson's correlation coefficient (r), effect size (ES), and standardized response mean (SRM) were calculated to assess the reliability, validity, and responsiveness of the SC-iHOT-33, respectively. Total Cronbach's alpha was 0.965, which represented excellent internal consistency of the SC-iHOT-33. The ICC ranges from 0.866 to 0.929, which shows excellent test-retest reliability. The subscales of SC-iHOT-33 had the highest correlation coefficient (r = 0.812) with the physical function subscales of the WOMAC, as well as good correlation between the social/emotional subscale of the SC-iHOT-33 and the EQ-5D (r = 0.740, r = 0.743). No floor or ceiling effects were found. The ES and SRM values indicated good responsiveness of 2.44 and 2.67, respectively. The SC-iHOT-33 questionnaire is reliable, valid, and responsive for the evaluation of young, Chinese, active patients with hip disorders. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  8. Correlation between tissue metabolism and cellularity assessed by standardized uptake value and apparent diffusion coefficient in peritoneal metastasis.

    PubMed

    Yu, Xue; Lee, Elaine Yuen Phin; Lai, Vincent; Chan, Queenie

    2014-07-01

    To evaluate the correlation between standardized uptake value (SUV) (tissue metabolism) and apparent diffusion coefficient (ADC) (water diffusivity) in peritoneal metastases. Patients with peritoneal dissemination detected on (18)F-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) were prospectively recruited for MRI examinations with informed consent and the study was approved by the local Institutional Review Board. FDG-PET/CT, diffusion-weighted imaging (DWI), MRI, and DWI/MRI images were independently reviewed by two radiologists based on visual analysis. SUVmax/SUVmean and ADCmin/ADCmean were obtained manually by drawing ROIs over the peritoneal metastases on FDG-PET/CT and DWI, respectively. Diagnostic characteristics of each technique were evaluated. Pearson's coefficient and McNemar and Kappa tests were used for statistical analysis. Eight patients were recruited for this prospective study and 34 peritoneal metastases were evaluated. ADCmean was significantly and negatively correlated with SUVmax (r = -0.528, P = 0.001) and SUVmean (r = -0.548, P = 0.001). ADCmin had similar correlation with SUVmax (r = -0.508, P = 0.002) and SUVmean (r = -0.513, P = 0.002). DWI/MRI had high diagnostic performance (accuracy = 98%) comparable to FDG-PET/CT, in peritoneal metastasis detection. Kappa values were excellent for all techniques. There was a significant inverse correlation between SUV and ADC. © 2013 Wiley Periodicals, Inc.

  9. Solvation free energies and partition coefficients with the coarse-grained and hybrid all-atom/coarse-grained MARTINI models.

    PubMed

    Genheden, Samuel

    2017-10-01

    We present the estimation of solvation free energies of small solutes in water, n-octanol and hexane using molecular dynamics simulations with two MARTINI models at different resolutions, viz. the coarse-grained (CG) and the hybrid all-atom/coarse-grained (AA/CG) models. From these estimates, we also calculate the water/hexane and water/octanol partition coefficients. More than 150 small, organic molecules were selected from the Minnesota solvation database and parameterized in a semi-automatic fashion. Using either the CG or hybrid AA/CG models, we find considerable deviations between the estimated and experimental solvation free energies in all solvents with mean absolute deviations larger than 10 kJ/mol, although the correlation coefficient is between 0.55 and 0.75 and significant. There is also no difference between the results when using the non-polarizable and polarizable water model, although we identify some improvements when using the polarizable model with the AA/CG solutes. In contrast to the estimated solvation energies, the estimated partition coefficients are generally excellent with both the CG and hybrid AA/CG models, giving mean absolute deviations between 0.67 and 0.90 log units and correlation coefficients larger than 0.85. We analyze the error distribution further and suggest avenues for improvements.

  10. Solvation free energies and partition coefficients with the coarse-grained and hybrid all-atom/coarse-grained MARTINI models

    NASA Astrophysics Data System (ADS)

    Genheden, Samuel

    2017-10-01

    We present the estimation of solvation free energies of small solutes in water, n-octanol and hexane using molecular dynamics simulations with two MARTINI models at different resolutions, viz. the coarse-grained (CG) and the hybrid all-atom/coarse-grained (AA/CG) models. From these estimates, we also calculate the water/hexane and water/octanol partition coefficients. More than 150 small, organic molecules were selected from the Minnesota solvation database and parameterized in a semi-automatic fashion. Using either the CG or hybrid AA/CG models, we find considerable deviations between the estimated and experimental solvation free energies in all solvents with mean absolute deviations larger than 10 kJ/mol, although the correlation coefficient is between 0.55 and 0.75 and significant. There is also no difference between the results when using the non-polarizable and polarizable water model, although we identify some improvements when using the polarizable model with the AA/CG solutes. In contrast to the estimated solvation energies, the estimated partition coefficients are generally excellent with both the CG and hybrid AA/CG models, giving mean absolute deviations between 0.67 and 0.90 log units and correlation coefficients larger than 0.85. We analyze the error distribution further and suggest avenues for improvements.

  11. Validity and reliability of a new tool to evaluate handwriting difficulties in Parkinson’s disease

    PubMed Central

    Nackaerts, Evelien; Heremans, Elke; Smits-Engelsman, Bouwien C. M.; Broeder, Sanne; Vandenberghe, Wim; Bergmans, Bruno; Nieuwboer, Alice

    2017-01-01

    Background Handwriting in Parkinson’s disease (PD) features specific abnormalities which are difficult to assess in clinical practice since no specific tool for evaluation of spontaneous movement is currently available. Objective This study aims to validate the ‘Systematic Screening of Handwriting Difficulties’ (SOS-test) in patients with PD. Methods Handwriting performance of 87 patients and 26 healthy age-matched controls was examined using the SOS-test. Sixty-seven patients were tested a second time within a period of one month. Participants were asked to copy as much as possible of a text within 5 minutes with the instruction to write as neatly and quickly as in daily life. Writing speed (letters in 5 minutes), size (mm) and quality of handwriting were compared. Correlation analysis was performed between SOS outcomes and other fine motor skill measurements and disease characteristics. Intrarater, interrater and test-retest reliability were assessed using the intraclass correlation coefficient (ICC) and Spearman correlation coefficient. Results Patients with PD had a smaller (p = 0.043) and slower (p<0.001) handwriting and showed worse writing quality (p = 0.031) compared to controls. The outcomes of the SOS-test significantly correlated with fine motor skill performance and disease duration and severity. Furthermore, the test showed excellent intrarater, interrater and test-retest reliability (ICC > 0.769 for both groups). Conclusion The SOS-test is a short and effective tool to detect handwriting problems in PD with excellent reliability. It can therefore be recommended as a clinical instrument for standardized screening of handwriting deficits in PD. PMID:28253374

  12. Reliability of shear wave ultrasound elastography for neck lesions identified in routine clinical practice.

    PubMed

    Bhatia, K; Tong, C S L; Cho, C C M; Yuen, E H Y; Lee, J; Ahuja, A T

    2012-10-01

    To evaluate the reliability of shear wave ultrasound elastography (SWE) in the neck. 176 neck lesions (40 thyroid, 56 lymph nodes, 46 salivary, 34 miscellaneous) identified in a routine US clinic underwent SWE by one or two blinded radiologists. For this study, SWE required the operator to acquire three 10 second dynamic colour-coded SWE cineloops per lesion, select one static image per cineloop, and place circular regions-of-interest within the entire lesion and stiffest part to generate 3 SWE measurements per static image. For logistical reasons, one radiologist evaluated all 176 lesions and the other evaluated 58 lesions. Both radiologists also reviewed 27 archived cineloops independently to assess SWE excluding practical technique. Reliability was assessed using intraclass correlation coefficients (ICCs) concordance correlation coefficients (CCCs) and coefficients of repeatability (CORs). Test-retest ICCs for the radiologist evaluating 176 lesions were 0.78 - 0.85 (fair-excellent agreement), CCCs were 0.85 - 0.88 (substantial agreement), and CORs were 14.9 - 36.1 kPa. For both radiologists evaluating 58 lesions, intra-rater and inter-rater ICCs were 0.65 - 0.78 and 0.72 - 0.77 respectively. For SWE excluding practical technique, inter-rater ICCs were 0.97 - 0.98 (excellent agreement). ICCs differed according to tissue, being higher in thyroid lesions than lymph nodes (p < 0.001), and higher in benign than malignant lesions (p values < 0.001). Intra- and inter-rater reliability of SWE is fair to excellent according to ICCs. SWE reliability is influenced appreciably by acquisition technique. Nevertheless, CORs for SWE are not negligible. To determine whether these results are acceptable clinically, further research is required to establish SWE stiffness values of normal and pathological tissues in the neck. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Excellent Intra and Inter-Observer Reproducibility of Wrist Circumference Measurements in Obese Children and Adolescents

    PubMed Central

    Campagna, Giuseppe; Zampetti, Simona; Gallozzi, Alessia; Giansanti, Sara; Chiesa, Claudio; Pacifico, Lucia; Buzzetti, Raffaella

    2016-01-01

    In a previous study, we found that wrist circumference, in particular its bone component, was associated with insulin resistance in a population of overweight/obese children. The aim of the present study was to evaluate the intra- and inter-operator variability in wrist circumference measurement in a population of obese children and adolescents. One hundred and two (54 male and 48 female) obese children and adolescents were consecutively enrolled. In all subjects wrist circumferences were measured by two different operators two times to assess intra- and inter-operator variability. Statistical analysis was performed using SAS v.9.4 and JMP v.12. Measurements of wrist circumference showed excellent inter-operator reliability with Intra class Correlation Coefficients (ICC) of 0.96 and ICC of 0.97 for the first and the second measurement, respectively. The intra-operator reliability was, also, very strong with a Concordance Correlation Coefficient (CCC) of 0.98 for both operators. The high reproducibility demonstrated in our results suggests that wrist circumference measurement, being safe, non-invasive and repeatable can be easily used in out-patient settings to identify youths with increased risk of insulin-resistance. This can avoid testing the entire population of overweight/obese children for insulin resistance parameters. PMID:27294398

  14. A simple method of measuring tibial tubercle to trochlear groove distance on MRI: description of a novel and reliable technique.

    PubMed

    Camp, Christopher L; Heidenreich, Mark J; Dahm, Diane L; Bond, Jeffrey R; Collins, Mark S; Krych, Aaron J

    2016-03-01

    Tibial tubercle-trochlear groove (TT-TG) distance is a variable that helps guide surgical decision-making in patients with patellar instability. The purpose of this study was to compare the accuracy and reliability of an MRI TT-TG measuring technique using a simple external alignment method to a previously validated gold standard technique that requires advanced software read by radiologists. TT-TG was calculated by MRI on 59 knees with a clinical diagnosis of patellar instability in a blinded and randomized fashion by two musculoskeletal radiologists using advanced software and by two orthopaedists using the study technique which utilizes measurements taken on a simple electronic imaging platform. Interrater reliability between the two radiologists and the two orthopaedists and intermethods reliability between the two techniques were calculated using interclass correlation coefficients (ICC) and concordance correlation coefficients (CCC). ICC and CCC values greater than 0.75 were considered to represent excellent agreement. The mean TT-TG distance was 14.7 mm (Standard Deviation (SD) 4.87 mm) and 15.4 mm (SD 5.41) as measured by the radiologists and orthopaedists, respectively. Excellent interobserver agreement was noted between the radiologists (ICC 0.941; CCC 0.941), the orthopaedists (ICC 0.978; CCC 0.976), and the two techniques (ICC 0.941; CCC 0.933). The simple TT-TG distance measurement technique analysed in this study resulted in excellent agreement and reliability as compared to the gold standard technique. This method can predictably be performed by orthopaedic surgeons without advanced radiologic software. II.

  15. Cross-cultural adaptation and validation of the Japanese version of the new Knee Society Scoring System for osteoarthritic knee with total knee arthroplasty.

    PubMed

    Hamamoto, Yosuke; Ito, Hiromu; Furu, Moritoshi; Ishikawa, Masahiro; Azukizawa, Masayuki; Kuriyama, Shinichi; Nakamura, Shinichiro; Matsuda, Shuichi

    2015-09-01

    The purposes of this study were to translate the new Knee Society Score (KSS) into Japanese and to evaluate the construct and content validity, test-retest reliability, and internal consistency of the Japanese version of the new KSS. The Japanese version of the KSS was developed according to cross-cultural guidelines by using the "translation-back translation" method to ensure content validity. KSS data were then obtained from patients who had undergone total knee arthroplasty (TKA). The psychometric properties evaluated were as follows: for feasibility, response rate, and floor and ceiling effects; for construct validity, internal consistency using Cronbach's alpha, and correlations with quality of life. Construct validity was evaluated by using Spearman's correlation coefficient to quantify the correlation between the KSS and the Japanese version of the Oxford 12-item Knee Score or Short Form 36 Health Survey (SF-36) questionnaires. The Japanese version of the KSS was sent to 93 consecutive osteoarthritic patients who underwent primary TKA in our institution. Fifty-five patients completed the questionnaires and were included in this study. Neither a floor nor ceiling effect was observed. The reliability proved excellent in the majority of domains, with intraclass correlation coefficients of 0.65-0.88. Internal consistency, assessed by Cronbach's alpha, was good to excellent for all domains (0.78-0.94). All of the four domains of the KSS correlated significantly with the Oxford 12-item Knee Score. The activity and satisfaction domains of the KSS correlated significantly with all and the majority of subscales of the SF-36, respectively, whereas symptoms and expectation domains showed significant correlations only with bodily pain and vitality subscales and with the physical function, bodily pain, and vitality subscales, respectively. The Japanese version of the new KSS is a valid, reliable, and responsive instrument to capture subjective aspects of the functional symptoms and abilities of patients who undergo TKA.

  16. Accuracy of contrast-enhanced spectral mammography for estimating residual tumor size after neoadjuvant chemotherapy in patients with breast cancer: a feasibility study

    PubMed Central

    Barra, Filipe Ramos; de Souza, Fernanda Freire; Camelo, Rosimara Eva Ferreira Almeida; Ribeiro, Andrea Campos de Oliveira; Farage, Luciano

    2017-01-01

    Objective To assess the feasibility of contrast-enhanced spectral mammography (CESM) of the breast for assessing the size of residual tumors after neoadjuvant chemotherapy (NAC). Materials and methods In breast cancer patients who underwent NAC between 2011 and 2013, we evaluated residual tumor measurements obtained with CESM and full-field digital mammography (FFDM). We determined the concordance between the methods, as well as their level of agreement with the pathology. Three radiologists analyzed eight CESM and FFDM measurements separately, considering the size of the residual tumor at its largest diameter and correlating it with that determined in the pathological analysis. Interobserver agreement was also evaluated. Results The sensitivity, specificity, positive predictive value, and negative predictive value were higher for CESM than for FFDM (83.33%, 100%, 100%, and 66% vs. 50%, 50%, 50%, and 25%, respectively). The CESM measurements showed a strong, consistent correlation with the pathological findings (correlation coefficient = 0.76-0.92; intraclass correlation coefficient = 0.692-0.886). The correlation between the FFDM measurements and the pathological findings was not statistically significant, with questionable consistency (intraclass correlation coefficient = 0.488-0.598). Agreement with the pathological findings was narrower for CESM measurements than for FFDM measurements. Interobserver agreement was higher for CESM than for FFDM (0.94 vs. 0.88). Conclusion CESM is a feasible means of evaluating residual tumor size after NAC, showing a good correlation and good agreement with pathological findings. For CESM measurements, the interobserver agreement was excellent. PMID:28894329

  17. Validation of general job satisfaction in the Korean Labor and Income Panel Study.

    PubMed

    Park, Shin Goo; Hwang, Sang Hee

    2017-01-01

    The purpose of this study is to assess the validity and reliability of general job satisfaction (JS) in the Korean Labor and Income Panel Study (KLIPS). We used the data from the 17th wave (2014) of the nationwide KLIPS, which selected a representative panel sample of Korean households and individuals aged 15 or older residing in urban areas. We included in this study 7679 employed subjects (4529 males and 3150 females). The general JS instrument consisted of five items rated on a scale from 1 (strongly disagree) to 5 (strongly agree). The general JS reliability was assessed using the corrected item-total correlation and Cronbach's alpha coefficient. The validity of general JS was assessed using confirmatory factor analysis (CFA) and Pearson's correlation. The corrected item-total correlations ranged from 0.736 to 0.837. Therefore, no items were removed. Cronbach's alpha for general JS was 0.925, indicating excellent internal consistency. The CFA of the general JS model showed a good fit. Pearson's correlation coefficients for convergent validity showed moderate or strong correlations. The results obtained in our study confirm the validity and reliability of general JS.

  18. The sizing of hamstring grafts for anterior cruciate reconstruction: intra- and inter-observer reliability.

    PubMed

    Dwyer, Tim; Whelan, Daniel B; Khoshbin, Amir; Wasserstein, David; Dold, Andrew; Chahal, Jaskarndip; Nauth, Aaron; Murnaghan, M Lucas; Ogilvie-Harris, Darrell J; Theodoropoulos, John S

    2015-04-01

    The objective of this study was to establish the intra- and inter-observer reliability of hamstring graft measurement using cylindrical sizing tubes. Hamstring tendons (gracilis and semitendinosus) were harvested from ten cadavers by a single surgeon and whip stitched together to create ten 4-strand hamstring grafts. Ten sports medicine surgeons and fellows sized each graft independently using either hollow cylindrical sizers or block sizers in 0.5-mm increments—the sizing technique used was applied consistently to each graft. Surgeons moved sequentially from graft to graft and measured each hamstring graft twice. Surgeons were asked to state the measured proximal (femoral) and distal (tibial) diameter of each graft, as well as the diameter of the tibial and femoral tunnels that they would drill if performing an anterior cruciate ligament (ACL) reconstruction using that graft. Reliability was established using intra-class correlation coefficients. Overall, both the inter-observer and intra-observer agreement were >0.9, demonstrating excellent reliability. The inter-observer reliability for drill sizes was also excellent (>0.9). Excellent correlation was seen between cylindrical sizing, and drill sizes (>0.9). Sizing of hamstring grafts by multiple surgeons demonstrated excellent intra-observer and intra-observer reliability, potentially validating clinical studies exploring ACL reconstruction outcomes by hamstring graft diameter when standard techniques are used. III.

  19. Predicting translational deformity following opening-wedge osteotomy for lower limb realignment.

    PubMed

    Barksfield, Richard C; Monsell, Fergal P

    2015-11-01

    An opening-wedge osteotomy is well recognised for the management of limb deformity and requires an understanding of the principles of geometry. Translation at the osteotomy is needed when the osteotomy is performed away from the centre of rotation of angulation (CORA), but the amount of translation varies with the distance from the CORA. This translation enables proximal and distal axes on either side of the proposed osteotomy to realign. We have developed two experimental models to establish whether the amount of translation required (based on the translation deformity created) can be predicted based upon simple trigonometry. A predictive algorithm was derived where translational deformity was predicted as 2(tan α × d), where α represents 50 % of the desired angular correction, and d is the distance of the desired osteotomy site from the CORA. A simulated model was developed using TraumaCad online digital software suite (Brainlab AG, Germany). Osteotomies were simulated in the distal femur, proximal tibia and distal tibia for nine sets of lower limb scanograms at incremental distances from the CORA and the resulting translational deformity recorded. There was strong correlation between the distance of the osteotomy from the CORA and simulated translation deformity for distal femoral deformities (correlation coefficient 0.99, p < 0.0001), proximal tibial deformities (correlation coefficient 0.93-0.99, p < 0.0001) and distal tibial deformities (correlation coefficient 0.99, p < 0.0001). There was excellent agreement between the predictive algorithm and simulated translational deformity for all nine simulations (correlation coefficient 0.93-0.99, p < 0.0001). Translational deformity following corrective osteotomy for lower limb deformity can be anticipated and predicted based upon the angular correction and the distance between the planned osteotomy site and the CORA.

  20. ScoreRel CI: An Excel Program for Computing Confidence Intervals for Commonly Used Score Reliability Coefficients

    ERIC Educational Resources Information Center

    Barnette, J. Jackson

    2005-01-01

    An Excel program developed to assist researchers in the determination and presentation of confidence intervals around commonly used score reliability coefficients is described. The software includes programs to determine confidence intervals for Cronbachs alpha, Pearson r-based coefficients such as those used in test-retest and alternate forms…

  1. Reliability and validity of the Chinese pediatric voice handicap index.

    PubMed

    Liu, Kena; Liu, Shaofeng; Zhou, Zhou; Ren, Qinyi; Zhong, Jie; Luo, Renzhong; Qin, Huabiao; Zhang, Siyi; Ge, Pingjiang

    2018-02-01

    To evaluate the reliability and validity of the Chinese version of pediatric voice handicap index (pVHI). The original English version-pVHI was translated into Chinese. Parents of 52 children with voice dysphonia and 43 children with no history or symptoms of voice problems were asked to fill the Chinese pVHI questionnaires twice with an interval of 2 weeks. GRB (Grade, Roughness, Breathiness) scale was used for perceptual assessment by two otolaryngologists and one speech pathologist for each child's voice. The internal consistency was assessed using Cronbach's alpha coefficient. Pearson's correlation coefficient was used to evaluate the test-retest reliability. The Kendall's coefficient of concordance W was used to assess the consistency of GRB scores of 3 voice specialists. The nonparametric Mann-Whitney test was used to assess the differences between the dysphonia group and controls. The correlation between pVHI and GRB scores were assessed using Pearson's correlation coefficient. The internal consistency of total score and three subscales scores of Chinese pVHI were 0.788-0.944. The test-retest reliability was 0.631-0.887(P < .001). The pVHI scores of control group significantly were lower than the pathological group (P = .000). The GRB scores of 3 voice specialists have an excellent consistency (W = 0.694-0.807, P = .000). The pVHI scores positively correlated with GRB assessment (P < .01). The Chinese version of pVHI had a good reliability and validity. It can be applicable and useful supplementary tool for evaluating parents' perception of their children's dysphonia. Copyright © 2017. Published by Elsevier B.V.

  2. Measuring internal friction of an ultrafast-folding protein.

    PubMed

    Cellmer, Troy; Henry, Eric R; Hofrichter, James; Eaton, William A

    2008-11-25

    Nanosecond laser T-jump was used to measure the viscosity dependence of the folding kinetics of the villin subdomain under conditions where the viscogen has no effect on its equilibrium properties. The dependence of the unfolding/refolding relaxation time on solvent viscosity indicates a major contribution to the dynamics from internal friction. The internal friction increases with increasing temperature, suggesting a shift in the transition state along the reaction coordinate toward the native state with more compact structures, and therefore, a smaller diffusion coefficient due to increased landscape roughness. Fitting the data with an Ising-like model yields a relatively small position dependence for the diffusion coefficient. This finding is consistent with the excellent correlation found between experimental and calculated folding rates based on free energy barrier heights using the same diffusion coefficient for every protein.

  3. The validation of the visual analogue scale for patient satisfaction after total hip arthroplasty.

    PubMed

    Brokelman, Roy B G; Haverkamp, Daniel; van Loon, Corné; Hol, Annemiek; van Kampen, Albert; Veth, Rene

    2012-06-01

    INTRODUCTION: Patient satisfaction becomes more important in our modern health care system. The assessment of satisfaction is difficult because it is a multifactorial item for which no golden standard exists. One of the potential methods of measuring satisfaction is by using the well-known visual analogue scale (VAS). In this study, we validated VAS for satisfaction. PATIENT AND METHODS: In this prospective study, we studied 147 patients (153 hips). The construct validity was measured using the Spearman correlation test that compares the satisfaction VAS with the Harris hip score, pain VAS at rest and during activity, Oxford hip score, Short Form 36 and Western Ontario McMaster Universities Osteoarthritis Index. The reliability was tested using the intra-class coefficient. RESULTS: The Pearson correlation test showed correlations in the range of 0.40-0.80. The satisfaction VAS had a high correlation between the pain VAS and Oxford hip score, which could mean that pain is one of the most important factors in patient satisfaction. The intra-class coefficient was 0.95. CONCLUSIONS: There is a moderate to mark degree of correlation between the satisfaction VAS and the currently available subjective and objective scoring systems. The intra-class coefficient of 0.95 indicates an excellent test-retest reliability. The VAS satisfaction is a simple instrument to quantify the satisfaction of a patient after total hip arthroplasty. In this study, we showed that the satisfaction VAS has a good validity and reliability.

  4. Dynamic contrast-enhanced MR imaging of the rectum: Correlations between single-section and whole-tumor histogram analyses.

    PubMed

    Choi, M H; Oh, S N; Park, G E; Yeo, D-M; Jung, S E

    2018-05-10

    To evaluate the interobserver and intermethod correlations of histogram metrics of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) parameters acquired by multiple readers using the single-section and whole-tumor volume methods. Four DCE parameters (K trans , K ep , V e , V p ) were evaluated in 45 patients (31 men and 14 women; mean age, 61±11 years [range, 29-83 years]) with locally advanced rectal cancer using pre-chemoradiotherapy (CRT) MRI. Ten histogram metrics were extracted using two methods of lesion selection performed by three radiologists: the whole-tumor volume method for the whole tumor on axial section-by-section images and the single-section method for the entire area of the tumor on one axial image. The interobserver and intermethod correlations were evaluated using the intraclass correlation coefficients (ICCs). The ICCs showed excellent interobserver and intermethod correlations in most of histogram metrics of the DCE parameters. The ICCs among the three readers were > 0.7 (P<0.001) for all histogram metrics, except for the minimum and maximum. The intermethod correlations for most of the histogram metrics were excellent for each radiologist, regardless of the differences in the radiologists' experience. The interobserver and intermethod correlations for most of the histogram metrics of the DCE parameters are excellent in rectal cancer. Therefore, the single-section method may be a potential alternative to the whole-tumor volume method using pre-CRT MRI, despite the fact that the high agreement between the two methods cannot be extrapolated to post-CRT MRI. Copyright © 2018 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  5. Cross-cultural adaptation and validation of the Turkish version of the pain catastrophizing scale among patients with ankylosing spondylitis

    PubMed Central

    İlçin, Nursen; Gürpınar, Barış; Bayraktar, Deniz; Savcı, Sema; Çetin, Pınar; Sarı, İsmail; Akkoç, Nurullah

    2016-01-01

    [Purpose] This study describes the cultural adaptation, validation, and reliability of the Turkish version of the Pain Catastrophizing Scale in patients with ankylosing spondylitis. [Methods] The validity of the Turkish version of the Pain Catastrophizing Scale was assessed by evaluating data quality (missing data and floor and ceiling effects), principal components analysis, internal consistency (Cronbach’s alpha), and construct validity (Spearman’s rho). Reproducibility analyses included standard measurement error, minimum detectable change, limits of agreement, and intraclass correlation coefficients. [Results] Sixty-four adult patients with ankylosing spondylitis with a mean age of 42.2 years completed the study. Factor analysis revealed that all questionnaire items could be grouped into two factors. Excellent internal consistency was found, with a Chronbach’s alpha value of 0.95. Reliability analyses showed an intraclass correlation coefficient (95% confidence interval) of 0.96 for the total score. There was a low correlation coefficient between the Turkish version of the Pain Catastrophizing Scale and body mass index, pain levels at rest and during activity, health-related quality of life, and fear and avoidance behaviors. [Conclusion] The results of this study indicate that the Turkish version of the Pain Catastrophizing Scale is a valid and reliable clinical and research tool for patients with ankylosing spondylitis. PMID:26957778

  6. Short version of the Depression Anxiety Stress Scale-21: is it valid for Brazilian adolescents?

    PubMed Central

    da Silva, Hítalo Andrade; dos Passos, Muana Hiandra Pereira; de Oliveira, Valéria Mayaly Alves; Palmeira, Aline Cabral; Pitangui, Ana Carolina Rodarti; de Araújo, Rodrigo Cappato

    2016-01-01

    ABSTRACT Objective To evaluate the interday reproducibility, agreement and validity of the construct of short version of the Depression Anxiety Stress Scale-21 applied to adolescents. Methods The sample consisted of adolescents of both sexes, aged between 10 and 19 years, who were recruited from schools and sports centers. The validity of the construct was performed by exploratory factor analysis, and reliability was calculated for each construct using the intraclass correlation coefficient, standard error of measurement and the minimum detectable change. Results The factor analysis combining the items corresponding to anxiety and stress in a single factor, and depression in a second factor, showed a better match of all 21 items, with higher factor loadings in their respective constructs. The reproducibility values for depression were intraclass correlation coefficient with 0.86, standard error of measurement with 0.80, and minimum detectable change with 2.22; and, for anxiety/stress: intraclass correlation coefficient with 0.82, standard error of measurement with 1.80, and minimum detectable change with 4.99. Conclusion The short version of the Depression Anxiety Stress Scale-21 showed excellent values of reliability, and strong internal consistency. The two-factor model with condensation of the constructs anxiety and stress in a single factor was the most acceptable for the adolescent population. PMID:28076595

  7. Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study

    PubMed Central

    Perraton, Luke G.; Bower, Kelly J.; Adair, Brooke; Pua, Yong-Hao; Williams, Gavin P.; McGaw, Rebekah

    2015-01-01

    Introduction Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power. Methods 30 healthy young adults (age: 23±5yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change. Results Comparison of RFD methods revealed that a peak 200ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ≥ 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ≥ 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31–0.79). Conclusions Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability and validity of these variables in clinical populations. PMID:26509265

  8. Cross-cultural adaptation and validation of the reliability of the Thai version of the Hip disability and Osteoarthritis Outcome Score (HOOS).

    PubMed

    Trathitiphan, Warayos; Paholpak, Permsak; Sirichativapee, Winai; Wisanuyotin, Taweechok; Laupattarakasem, Pat; Sukhonthamarn, Kamolsak; Jeeravipoolvarn, Polasak; Kosuwon, Weerachai

    2016-10-01

    HOOS was developed as an extension of the Western Ontario and McMaster Universities' Osteoarthritis Index questionnaire for measuring symptoms and functional limitations related to the hip(s) of patients with osteoarthritis. To determine the validity and reliability of the Thai version of the Hip disability and Osteoarthritis Outcome Score (HOOS) vis-à-vis hip osteoarthritis, the original HOOS was translated into a Thai version of HOOS, according to international recommendations. Patients with hip osteoarthritis (n = 57; 25 males) were asked to complete the Thai version of HOOS twice: once then again after a 3-week interval. The test-retest reliability was analyzed using the intraclass correlation coefficient (ICC). Internal consistencies were analyzed using Cronbach's alpha, while the construct validity was tested by comparing the Thai HOOS with the Thai modified SF-36 and calculating the Spearman's rank correlation coefficients. The Thai HOOS produced good reliability (i.e., the ICC was greater than 0.9 in all five subscales). All of the Cronbach's alpha showed that the Thai HOOS had high internal consistency (Cronbach's alpha greater than 0.8), especially for the pain and ADL subscales (0.89 and 0.90, respectively). The Spearman's rank correlation for all five subscales of the Thai HOOS had moderate correlation with the Bodily Pain subscale of the Thai SF-36. The pain subscale of the Thai HOOS had a high correlation with the Vitality and Social Function subscales of the Thai SF-36 (r = 0.55 and 0.54)-with which the symptom subscale had a moderate correlation. The Thai version of HOOS had excellent internal consistency, excellent test-retest reliability, and good construct validity. It can be used as a reliable tool for assessing quality of life for patients with hip osteoarthritis in Thailand.

  9. A comparative study of software programmes for cross-sectional skeletal muscle and adipose tissue measurements on abdominal computed tomography scans of rectal cancer patients.

    PubMed

    van Vugt, Jeroen L A; Levolger, Stef; Gharbharan, Arvind; Koek, Marcel; Niessen, Wiro J; Burger, Jacobus W A; Willemsen, Sten P; de Bruin, Ron W F; IJzermans, Jan N M

    2017-04-01

    The association between body composition (e.g. sarcopenia or visceral obesity) and treatment outcomes, such as survival, using single-slice computed tomography (CT)-based measurements has recently been studied in various patient groups. These studies have been conducted with different software programmes, each with their specific characteristics, of which the inter-observer, intra-observer, and inter-software correlation are unknown. Therefore, a comparative study was performed. Fifty abdominal CT scans were randomly selected from 50 different patients and independently assessed by two observers. Cross-sectional muscle area (CSMA, i.e. rectus abdominis, oblique and transverse abdominal muscles, paraspinal muscles, and the psoas muscle), visceral adipose tissue area (VAT), and subcutaneous adipose tissue area (SAT) were segmented by using standard Hounsfield unit ranges and computed for regions of interest. The inter-software, intra-observer, and inter-observer agreement for CSMA, VAT, and SAT measurements using FatSeg, OsiriX, ImageJ, and sliceOmatic were calculated using intra-class correlation coefficients (ICCs) and Bland-Altman analyses. Cohen's κ was calculated for the agreement of sarcopenia and visceral obesity assessment. The Jaccard similarity coefficient was used to compare the similarity and diversity of measurements. Bland-Altman analyses and ICC indicated that the CSMA, VAT, and SAT measurements between the different software programmes were highly comparable (ICC 0.979-1.000, P < 0.001). All programmes adequately distinguished between the presence or absence of sarcopenia (κ = 0.88-0.96 for one observer and all κ = 1.00 for all comparisons of the other observer) and visceral obesity (all κ = 1.00). Furthermore, excellent intra-observer (ICC 0.999-1.000, P < 0.001) and inter-observer (ICC 0.998-0.999, P < 0.001) agreement for all software programmes were found. Accordingly, excellent Jaccard similarity coefficients were found for all comparisons (mean ≥ 0.964). FatSeg, OsiriX, ImageJ, and sliceOmatic showed an excellent agreement for CSMA, VAT, and SAT measurements on abdominal CT scans. Furthermore, excellent inter-observer and intra-observer agreement were achieved. Therefore, results of studies using these different software programmes can reliably be compared. © 2016 The Authors. Journal of Cachexia, Sarcopenia and Muscle published by John Wiley & Sons Ltd on behalf of the Society on Sarcopenia, Cachexia and Wasting Disorders.

  10. A comparative study of software programmes for cross‐sectional skeletal muscle and adipose tissue measurements on abdominal computed tomography scans of rectal cancer patients

    PubMed Central

    Levolger, Stef; Gharbharan, Arvind; Koek, Marcel; Niessen, Wiro J.; Burger, Jacobus W.A.; Willemsen, Sten P.; de Bruin, Ron W.F.

    2016-01-01

    Abstract Background The association between body composition (e.g. sarcopenia or visceral obesity) and treatment outcomes, such as survival, using single‐slice computed tomography (CT)‐based measurements has recently been studied in various patient groups. These studies have been conducted with different software programmes, each with their specific characteristics, of which the inter‐observer, intra‐observer, and inter‐software correlation are unknown. Therefore, a comparative study was performed. Methods Fifty abdominal CT scans were randomly selected from 50 different patients and independently assessed by two observers. Cross‐sectional muscle area (CSMA, i.e. rectus abdominis, oblique and transverse abdominal muscles, paraspinal muscles, and the psoas muscle), visceral adipose tissue area (VAT), and subcutaneous adipose tissue area (SAT) were segmented by using standard Hounsfield unit ranges and computed for regions of interest. The inter‐software, intra‐observer, and inter‐observer agreement for CSMA, VAT, and SAT measurements using FatSeg, OsiriX, ImageJ, and sliceOmatic were calculated using intra‐class correlation coefficients (ICCs) and Bland–Altman analyses. Cohen's κ was calculated for the agreement of sarcopenia and visceral obesity assessment. The Jaccard similarity coefficient was used to compare the similarity and diversity of measurements. Results Bland–Altman analyses and ICC indicated that the CSMA, VAT, and SAT measurements between the different software programmes were highly comparable (ICC 0.979–1.000, P < 0.001). All programmes adequately distinguished between the presence or absence of sarcopenia (κ = 0.88–0.96 for one observer and all κ = 1.00 for all comparisons of the other observer) and visceral obesity (all κ = 1.00). Furthermore, excellent intra‐observer (ICC 0.999–1.000, P < 0.001) and inter‐observer (ICC 0.998–0.999, P < 0.001) agreement for all software programmes were found. Accordingly, excellent Jaccard similarity coefficients were found for all comparisons (mean ≥ 0.964). Conclusions FatSeg, OsiriX, ImageJ, and sliceOmatic showed an excellent agreement for CSMA, VAT, and SAT measurements on abdominal CT scans. Furthermore, excellent inter‐observer and intra‐observer agreement were achieved. Therefore, results of studies using these different software programmes can reliably be compared. PMID:27897414

  11. Test-Retest Reliability and Minimal Detectable Change of Randomized Dichotic Digits in Learning-Disabled Children: Implications for Dichotic Listening Training.

    PubMed

    Mahdavi, Mohammad Ebrahim; Pourbakht, Akram; Parand, Akram; Jalaie, Shohreh

    2018-03-01

    Evaluation of dichotic listening to digits is a common part of many studies for diagnosis and managing auditory processing disorders in children. Previous researchers have verified test-retest relative reliability of dichotic digits results in normal children and adults. However, detecting intervention-related changes in the ear scores after dichotic listening training requires information regarding trial-to-trial typical variation of individual ear scores that is estimated using indices of absolute reliability. Previous studies have not addressed absolute reliability of dichotic listening results. To compare the results of the Persian randomized dichotic digits test (PRDDT) and its relative and absolute indices of reliability between typical achieving (TA) and learning-disabled (LD) children. A repeated measures observational study. Fifteen LD children were recruited from a previously performed study with age range of 7-12 yr. The control group consisted of 15 TA schoolchildren with age range of 8-11 yr. The Persian randomized dichotic digits test was administered on the children under free recall condition in two test sessions 7-12 days apart. We compared the average of the ear scores and ear advantage between TA and LD children. Relative indices of reliability included Pearson's correlation and intraclass correlation (ICC 2,1 ) coefficients and absolute reliability was evaluated by calculation of standard error of measurement (SEM) and minimal detectable change (MDC) using the raw ear scores. The Pearson correlation coefficient indicated that in both groups of children the ear scores of test and retest sessions were strongly and positively (greater than +0.8) correlated. The ear scores showed excellent ICC coefficient of consistency (0.78-0.82) and fair to excellent ICC coefficient of absolute agreement (0.62-0.74) in TA children and excellent ICC coefficients of consistency and absolute agreement in LD children (0.76-0.87). SEM and SEM% of the ear scores in TA children were 1.46 and 1.44% for the right ear and 4.68 and 5.47% for the left ear. SEM and SEM% of the ear scores in LD children were 4.55 and 5.88% for the right ear to 7.56 and 12.81% for the left ear. MDC and MDC% of the ear scores in TA children varied from 4.03 and 3.99% for the right ear to 12.93 and 15.13% for the left ear. MDC and MDC% of the ear scores in LD children varied from 12.57 and 16.25% for the right ear to 20.89 and 35.39% for the left ear. The LD children indicated test-retest relative reliability as high as TA children in the ear scores measured by PRDDT. However, within-subject variations of the ear scores calculated by indices of absolute reliability were considerably higher in LD children versus TA children. The results of the current study could have implications for detecting real training-related changes in the ear scores. American Academy of Audiology

  12. Coding stimulus amplitude by correlated neural activity

    NASA Astrophysics Data System (ADS)

    Metzen, Michael G.; Ávila-Åkerberg, Oscar; Chacron, Maurice J.

    2015-04-01

    While correlated activity is observed ubiquitously in the brain, its role in neural coding has remained controversial. Recent experimental results have demonstrated that correlated but not single-neuron activity can encode the detailed time course of the instantaneous amplitude (i.e., envelope) of a stimulus. These have furthermore demonstrated that such coding required and was optimal for a nonzero level of neural variability. However, a theoretical understanding of these results is still lacking. Here we provide a comprehensive theoretical framework explaining these experimental findings. Specifically, we use linear response theory to derive an expression relating the correlation coefficient to the instantaneous stimulus amplitude, which takes into account key single-neuron properties such as firing rate and variability as quantified by the coefficient of variation. The theoretical prediction was in excellent agreement with numerical simulations of various integrate-and-fire type neuron models for various parameter values. Further, we demonstrate a form of stochastic resonance as optimal coding of stimulus variance by correlated activity occurs for a nonzero value of noise intensity. Thus, our results provide a theoretical explanation of the phenomenon by which correlated but not single-neuron activity can code for stimulus amplitude and how key single-neuron properties such as firing rate and variability influence such coding. Correlation coding by correlated but not single-neuron activity is thus predicted to be a ubiquitous feature of sensory processing for neurons responding to weak input.

  13. Modified schirmer test--a screening tool for xerostomia among subjects on antidepressants.

    PubMed

    Kumar, Nerella Narendra; Panchaksharappa, Mamatha Gowda; Annigeri, Rajeshwari G

    2014-08-01

    The aim of the present study is to assess salivary flow rate in the subjects who were on antidepressant medications and its comparison with healthy controls and assessment of unstimulated salivary flow rate by modified Schirmer test (MST) and volumetric method (spitting method) for evaluation of xerostomia and whether any correlation exists between two methods. Thirty subjects who were on antidepressants were divided into two groups: tricyclic antidepressants (TCA) and selective sertonin reuptake inhibitors (SSRI) of 15 each, compared with 30 age and gender matched controls. Unstimulated salivary flow rate was measured by both MST and spitting method. The unstimulated salivary flow rate measured by MST at the end of 3rd minute was 13.7 ± 10.08, 19.86 ± 8.95 and 31.0 ± 5.4 mm and by spitting method was 0.12 ± 0.07, 0.19 ± 0.10 and 0.30 ± 0.75 ml/min in TCA, SSRI and controls respectively (p<0.001). The Pearson correlation coefficient of r=0.85 shows excellent correlation between the two screening tests. Sensitivity and Specificity of MST was 90.9% and 31.5%. Salivary flow rate was less in antidepressant subjects when compared to the healthy controls. Results of the present study showed an excellent correlation excellent correlation between the two screening tests which suggests that MST can be routinely used as chair-side screening tool to evaluate hyposalivation which is time saving, patient friendly and specific of salivary secretions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. ImageJ: A Free, Easy, and Reliable Method to Measure Leg Ulcers Using Digital Pictures.

    PubMed

    Aragón-Sánchez, Javier; Quintana-Marrero, Yurena; Aragón-Hernández, Cristina; Hernández-Herero, María José

    2017-12-01

    Wound measurement to document the healing course of chronic leg ulcers has an important role in the management of these patients. Digital cameras in smartphones are readily available and easy to use, and taking pictures of wounds is becoming a routine in specialized departments. Analyzing digital pictures with appropriate software provides clinicians a quick, clean, and easy-to-use tool for measuring wound area. A set of 25 digital pictures of plain foot and leg ulcers was the basis of this study. Photographs were taken placing a ruler next to the wound in parallel with the healthy skin with the iPhone 6S (Apple Inc, Cupertino, CA), which has a camera of 12 megapixels using the flash. The digital photographs were visualized with ImageJ 1.45s freeware (National Institutes of Health, Rockville, MD; http://imagej.net/ImageJ ). Wound area measurement was carried out by 4 raters: head of the department, wound care nurse, physician, and medical student. We assessed intra- and interrater reliability using the interclass correlation coefficient. To determine intraobserver reliability, 2 of the raters repeated the measurement of the set 1 week after the first reading. The interrater model displayed an interclass correlation coefficient of 0.99 with 95% confidence interval of 0.999 to 1.000, showing excellent reliability. The intrarater model of both examiners showed excellent reliability. In conclusion, analyzing digital images of leg ulcers with ImageJ estimates wound area with excellent reliability. This method provides a free, rapid, and accurate way to measure wounds and could routinely be used to document wound healing in daily clinical practice.

  15. Measurement Properties of the Lower Extremity Functional Scale: A Systematic Review.

    PubMed

    Mehta, Saurabh P; Fulton, Allison; Quach, Cedric; Thistle, Megan; Toledo, Cesar; Evans, Neil A

    2016-03-01

    Systematic review of measurement properties. Many primary studies have examined the measurement properties, such as reliability, validity, and sensitivity to change, of the Lower Extremity Functional Scale (LEFS) in different clinical populations. A systematic review summarizing these properties for the LEFS may provide an important resource. To locate and synthesize evidence on the measurement properties of the LEFS and to discuss the clinical implications of the evidence. A literature search was conducted in 4 databases (PubMed, MEDLINE, Embase, and CINAHL), using predefined search terms. Two reviewers performed a critical appraisal of the included studies using a standardized assessment form. A total of 27 studies were included in the review, of which 18 achieved a very good to excellent methodological quality level. The LEFS scores demonstrated excellent test-retest reliability (intraclass correlation coefficients ranging between 0.85 and 0.99) and demonstrated the expected relationships with measures assessing similar constructs (Pearson correlation coefficient values of greater than 0.7). The responsiveness of the LEFS scores was excellent, as suggested by consistently high effect sizes (greater than 0.8) in patients with different lower extremity conditions. Minimal detectable change at the 90% confidence level (MDC90) for the LEFS scores varied between 8.1 and 15.3 across different reassessment intervals in a wide range of patient populations. The pooled estimate of the MDC90 was 6 points and the minimal clinically important difference was 9 points in patients with lower extremity musculoskeletal conditions, which are indicative of true change and clinically meaningful change, respectively. The results of this review support the reliability, validity, and responsiveness of the LEFS scores for assessing functional impairment in a wide array of patient groups with lower extremity musculoskeletal conditions.

  16. Non-Weight-Bearing and Weight-Bearing Ultrasonography of Select Foot Muscles in Young, Asymptomatic Participants: A Descriptive and Reliability Study.

    PubMed

    Battaglia, Patrick J; Mattox, Ross; Winchester, Brett; Kettner, Norman W

    The primary aim of this study was to determine the reliability of diagnostic ultrasound imaging for select intrinsic foot muscles using both non-weight-bearing and weight-bearing postures. Our secondary aim was to describe the change in muscle cross-sectional area (CSA) and dorsoplantar thickness when bearing weight. An ultrasound examination was performed with a linear ultrasound transducer operating between 9 and 12 MHz. Long-axis and short-axis ultrasound images of the abductor hallucis, flexor digitorum brevis, and quadratus plantae were obtained in both the non-weight-bearing and weight-bearing postures. Two examiners independently collected ultrasound images to allow for interexaminer and intraexaminer reliability calculation. The change in muscle CSA and dorsoplantar thickness when bearing weight was also studied. There were 26 participants (17 female) with a mean age of 25.5 ± 3.8 years and a mean body mass index of 28.0 ± 7.8 kg/m 2 . Inter-examiner reliability was excellent when measuring the muscles in short axis (intraclass correlation coefficient >0.75) and fair to good in long axis (intraclass correlation coefficient >0.4). Intraexaminer reliability was excellent for the abductor hallucis and flexor digitorum brevis and ranged from fair to good to excellent for the quadratus plantae. Bearing weight did not reduce interexaminer or intraexaminer reliability. All muscles exhibited a significant increase in CSA when bearing weight. This is the first report to describe weight-bearing diagnostic ultrasound of the intrinsic foot muscles. Ultrasound imaging is reliable when imaging these muscles bearing weight. Furthermore, muscle CSA increases in the weight-bearing posture. Copyright © 2016. Published by Elsevier Inc.

  17. Validation of the UNESP-Botucatu unidimensional composite pain scale for assessing postoperative pain in cattle.

    PubMed

    de Oliveira, Flávia Augusta; Luna, Stelio Pacca Loureiro; do Amaral, Jackson Barros; Rodrigues, Karoline Alves; Sant'Anna, Aline Cristina; Daolio, Milena; Brondani, Juliana Tabarelli

    2014-09-06

    The recognition and measurement of pain in cattle are important in determining the necessity for and efficacy of analgesic intervention. The aim of this study was to record behaviour and determine the validity and reliability of an instrument to assess acute pain in 40 cattle subjected to orchiectomy after sedation with xylazine and local anaesthesia. The animals were filmed before and after orchiectomy to record behaviour. The pain scale was based on previous studies, on a pilot study and on analysis of the camera footage. Three blinded observers and a local observer assessed the edited films obtained during the preoperative and postoperative periods, before and after rescue analgesia and 24 hours after surgery. Re-evaluation was performed one month after the first analysis. Criterion validity (agreement) and item-total correlation using Spearman's coefficient were employed to refine the scale. Based on factor analysis, a unidimensional scale was adopted. The internal consistency of the data was excellent after refinement (Cronbach's α coefficient = 0.866). There was a high correlation (p < 0.001) between the proposed scale and the visual analogue, simple descriptive and numerical rating scales. The construct validity and responsiveness were confirmed by the increase and decrease in pain scores after surgery and rescue analgesia, respectively (p < 0.001). Inter- and intra-observer reliability ranged from moderate to very good. The optimal cut-off point for rescue analgesia was > 4, and analysis of the area under the curve (AUC = 0.963) showed excellent discriminatory ability. The UNESP-Botucatu unidimensional pain scale for assessing acute postoperative pain in cattle is a valid, reliable and responsive instrument with excellent internal consistency and discriminatory ability. The cut-off point for rescue analgesia provides an additional tool for guiding analgesic therapy.

  18. The efficacy of the Microsoft KinectTM to assess human bimanual coordination.

    PubMed

    Liddy, Joshua J; Zelaznik, Howard N; Huber, Jessica E; Rietdyk, Shirley; Claxton, Laura J; Samuel, Arjmand; Haddad, Jeffrey M

    2017-06-01

    The Microsoft Kinect has been used in studies examining posture and gait. Despite the advantages of portability and low cost, this device has not been used to assess interlimb coordination. Fundamental insights into movement control, variability, health, and functional status can be gained by examining coordination patterns. In this study, we investigated the efficacy of the Microsoft Kinect to capture bimanual coordination relative to a research-grade motion capture system. Twenty-four healthy adults performed coordinated hand movements in two patterns (in-phase and antiphase) at eight movement frequencies (1.00-3.33 Hz). Continuous relative phase (CRP) and discrete relative phase (DRP) were used to quantify the means (mCRP and mDRP) and variability (sdCRP and sdDRP) of coordination patterns. Between-device agreement was assessed using Bland-Altman bias with 95 % limits of agreement, concordance correlation coefficients (absolute agreement), and Pearson correlation coefficients (relative agreement). Modest-to-excellent relative and absolute agreements were found for mCRP in all conditions. However, mDRP showed poor agreement for the in-phase pattern at low frequencies, due to large between-device differences in a subset of participants. By contrast, poor absolute agreement was observed for both sdCRP and sdDRP, while relative agreement ranged from poor to excellent. Overall, the Kinect captures the macroscopic patterns of bimanual coordination better than coordination variability.

  19. Comparison of Automated Brain Volume Measures obtained with NeuroQuant and FreeSurfer.

    PubMed

    Ochs, Alfred L; Ross, David E; Zannoni, Megan D; Abildskov, Tracy J; Bigler, Erin D

    2015-01-01

    To examine intermethod reliabilities and differences between FreeSurfer and the FDA-cleared congener, NeuroQuant, both fully automated methods for structural brain MRI measurements. MRI scans from 20 normal control subjects, 20 Alzheimer's disease patients, and 20 mild traumatically brain-injured patients were analyzed with NeuroQuant and with FreeSurfer. Intermethod reliability was evaluated. Pairwise correlation coefficients, intraclass correlation coefficients, and effect size differences were computed. NeuroQuant versus FreeSurfer measures showed excellent to good intermethod reliability for the 21 regions evaluated (r: .63 to .99/ICC: .62 to .99/ES: -.33 to 2.08) except for the pallidum (r/ICC/ES = .31/.29/-2.2) and cerebellar white matter (r/ICC/ES = .31/.31/.08). Volumes reported by NeuroQuant were generally larger than those reported by FreeSurfer with the whole brain parenchyma volume reported by NeuroQuant 6.50% larger than the volume reported by FreeSurfer. There was no systematic difference in results between the 3 subgroups. NeuroQuant and FreeSurfer showed good to excellent intermethod reliability in volumetric measurements for all brain regions examined with the only exceptions being the pallidum and cerebellar white matter. This finding was robust for normal individuals, patients with Alzheimer's disease, and patients with mild traumatic brain injury. Copyright © 2015 by the American Society of Neuroimaging.

  20. Measurement of the area of venous ulcers using two software programs 1

    PubMed Central

    Eberhardt, Thaís Dresch; de Lima, Suzinara Beatriz Soares; Lopes, Luis Felipe Dias; Borges, Eline de Lima; Weiller, Teresinha Heck; da Fonseca, Graziele Gorete Portella

    2016-01-01

    ABSTRACT Objective: to compare the measurement area of venous ulcers using AutoCAD(r) and Image Tool software. Method: this was an assessment of reproducibility tests conducted in a angiology clinic of a university hospital. Data were collected from 21 patients with venous ulcers, in the period from March to July of 2015, using a collection form and photograph of wounds. Five nurses (evaluators) of the hospital skin wound study group participated. The wounds were measured using both software programs. Data were analyzed using intraclass correlation coefficient, concordance correlation coefficient and Bland-Altman analysis. The study met the ethical aspects in accordance with current legislation. Results: the size of ulcers varied widely, however, without significant difference between the measurements; an excellent intraclass and concordance correlation was found between both software programs, which seem to be more accurate when measuring a wound area >10 cm². Conclusion: the use of both software programs is appropriate for measurement of venous ulcers, appearing to be more accurate when used to measure a wound area > 10 cm². PMID:27992028

  1. Open source posturography.

    PubMed

    Rey-Martinez, Jorge; Pérez-Fernández, Nicolás

    2016-12-01

    The proposed validation goal of 0.9 in intra-class correlation coefficient was reached with the results of this study. With the obtained results we consider that the developed software (RombergLab) is a validated balance assessment software. The reliability of this software is dependent of the used force platform technical specifications. Develop and validate a posturography software and share its source code in open source terms. Prospective non-randomized validation study: 20 consecutive adults underwent two balance assessment tests, six condition posturography was performed using a clinical approved software and force platform and the same conditions were measured using the new developed open source software using a low cost force platform. Intra-class correlation index of the sway area obtained from the center of pressure variations in both devices for the six conditions was the main variable used for validation. Excellent concordance between RombergLab and clinical approved force platform was obtained (intra-class correlation coefficient =0.94). A Bland and Altman graphic concordance plot was also obtained. The source code used to develop RombergLab was published in open source terms.

  2. Measuring family-centred practices of professionals in early intervention services in Taiwan.

    PubMed

    Kang, L-J; Palisano, R J; Simeonsson, R J; Hwang, A-W

    2017-09-01

    Family-centred practices emphasize professional supports for forming partnerships with families in early intervention. The Measure of Processes of Care for Service Providers (MPOC-SP) measures the perceptions of paediatric service providers in supporting children and families. This study aimed to establish reliability of the Chinese version of the MPOC-SP (C-MPOC-SP) and to examine professional perceptions of family-centred practices in relation to professional discipline and years of experience. A convenience sample of 94 physical therapists, occupational therapists, speech-language pathologists, social workers and early childhood educators completed the C-MPOC-SP. Thirty-seven professionals completed the measure a second time within 2-4 weeks for test-retest reliability. Internal consistency and test-retest reliability were examined by Cronbach's α and intra-class correlation coefficient. Comparisons were made across professional disciplines by multivariate analyses of variance followed by analyses of variance. Relationships between years of experience and ratings of family-centred practices were examined by Pearson's correlation coefficients (r). Cronbach's α for items on each of the four scales of the C-MPOC-SP ranged from 0.80 to 0.92, indicating adequate internal consistency. Intra-class correlation coefficient between the initial and repeat completion of the C-MPOC-SP for each scale ranged from 0.56 to 0.77, indicating adequate to excellent test-retest reliability. Mean ratings for the Communicating Specific Information were significantly higher for physical therapists, occupational therapists and speech-language pathologists than for social workers (P = 0.001). The C-MPOC-SP scores were positively correlated with years of experience for all four scales (r = 0.23-0.38; P < 0.05). This study established adequate internal consistency and adequate to excellent test-retest reliability of the C-MPOC-SP in measuring perceptions of family centeredness of early intervention service providers. Cross-discipline differences were found in communicating specific information about the child. Higher perceptions of family centeredness were associated with more years of experience. The results support the utility of the C-MPOC-SP in professional education and programme evaluation of early intervention services in Taiwan. © 2017 John Wiley & Sons Ltd.

  3. Repeatability of Computerized Tomography-Based Anthropomorphic Measurements of Frailty in Patients With Pulmonary Fibrosis Undergoing Lung Transplantation.

    PubMed

    McClellan, Taylor; Allen, Brian C; Kappus, Matthew; Bhatti, Lubna; Dafalla, Randa A; Snyder, Laurie D; Bashir, Mustafa R

    To determine interreader and intrareader repeatability and correlations among measurements of computerized tomography-based anthropomorphic measurements in patients with pulmonary fibrosis undergoing lung transplantation. This was an institutional review board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study of 23 randomly selected subjects (19 male and 4 female; median age = 69 years; range: 66-77 years) with idiopathic pulmonary fibrosis undergoing pulmonary transplantation, who had also undergone preoperative thoracoabdominal computerized tomography. Five readers of varying imaging experience independently performed the following cross-sectional area measurements at the inferior endplate of the L3 vertebral body: right and left psoas muscles, right and left paraspinal muscles, total abdominal musculature, and visceral and subcutaneous fat. The following measurements were obtained at the inferior endplate of T6: right and left paraspinal muscles with and without including the trapezius muscles and subcutaneous fat. Three readers repeated all measurements to assess intrareader repeatability. Intrareader repeatability was nearly perfect (interclass correlation coefficients = 0.99, P < 0.001). Interreader agreement was excellent across all 5 readers (interclass correlation coefficients: 0.71-0.99, P < 0.001). Coefficients of variance between measures ranged from 3.2%-6.8% for abdominal measurements, but were higher for thoracic measurements, up to 23.9%. Correlation between total paraspinal and total psoas muscle area was strong (r 2 = 0.67, P < 0.001). Thoracic and abdominal musculature had a weaker correlation (r 2 = 0.35-0.38, P < 0.001). Measures of thoracic and abdominal muscle and fat area are highly repeatable in patients with pulmonary fibrosis undergoing lung transplantation. Measures of muscle area are strongly correlated among abdominal locations, but inversely correlated between abdominal and thoracic locations. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion.

    PubMed

    Charlton, Paula C; Mentiplay, Benjamin F; Pua, Yong-Hao; Clark, Ross A

    2015-05-01

    Traditional methods of assessing joint range of motion (ROM) involve specialized tools that may not be widely available to clinicians. This study assesses the reliability and validity of a custom Smartphone application for assessing hip joint range of motion. Intra-tester reliability with concurrent validity. Passive hip joint range of motion was recorded for seven different movements in 20 males on two separate occasions. Data from a Smartphone, bubble inclinometer and a three dimensional motion analysis (3DMA) system were collected simultaneously. Intraclass correlation coefficients (ICCs), coefficients of variation (CV) and standard error of measurement (SEM) were used to assess reliability. To assess validity of the Smartphone application and the bubble inclinometer against the three dimensional motion analysis system, intraclass correlation coefficients and fixed and proportional biases were used. The Smartphone demonstrated good to excellent reliability (ICCs>0.75) for four out of the seven movements, and moderate to good reliability for the remaining three movements (ICC=0.63-0.68). Additionally, the Smartphone application displayed comparable reliability to the bubble inclinometer. The Smartphone application displayed excellent validity when compared to the three dimensional motion analysis system for all movements (ICCs>0.88) except one, which displayed moderate to good validity (ICC=0.71). Smartphones are portable and widely available tools that are mostly reliable and valid for assessing passive hip range of motion, with potential for large-scale use when a bubble inclinometer is not available. However, caution must be taken in its implementation as some movement axes demonstrated only moderate reliability. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  5. Accurate van der Waals coefficients from density functional theory

    PubMed Central

    Tao, Jianmin; Perdew, John P.; Ruzsinszky, Adrienn

    2012-01-01

    The van der Waals interaction is a weak, long-range correlation, arising from quantum electronic charge fluctuations. This interaction affects many properties of materials. A simple and yet accurate estimate of this effect will facilitate computer simulation of complex molecular materials and drug design. Here we develop a fast approach for accurate evaluation of dynamic multipole polarizabilities and van der Waals (vdW) coefficients of all orders from the electron density and static multipole polarizabilities of each atom or other spherical object, without empirical fitting. Our dynamic polarizabilities (dipole, quadrupole, octupole, etc.) are exact in the zero- and high-frequency limits, and exact at all frequencies for a metallic sphere of uniform density. Our theory predicts dynamic multipole polarizabilities in excellent agreement with more expensive many-body methods, and yields therefrom vdW coefficients C6, C8, C10 for atom pairs with a mean absolute relative error of only 3%. PMID:22205765

  6. Multidirectional walk test in individuals with Parkinson's disease: a validity study.

    PubMed

    Bryant, Mon S; Workman, Craig D; Jackson, George R

    2015-03-01

    Gait parameters of forward, backward, and sideways walk were studied when the participants walked overground in four directions at their self-selected speed and were compared with walking in the four directions on an instrumented GAITRite walkway. Intraclass correlation coefficients between the overground walk test measures and the instrumented walkway measures of gait speed, cadence, and stride length for the forward walk were 0.85, 0.88, and 0.87, respectively. For the backward walk, the coefficients were 0.91 for gait speed, 0.75 for cadence, and 0.93 for stride length. For the sideways walk, the coefficients were 0.92 for gait speed, 0.93 for cadence, and 0.94 for stride length. Gait parameters of forward, backward, and sideways walk obtained by the overground walk test had excellent agreement with those obtained by the instrumented walkway. The quick timed test provided quantitative data for gait evaluation and was valid for clinical use.

  7. The medial dye pool revisited: correlation between arthrography and MRI In closed reductions for DDH.

    PubMed

    Gans, Itai; Sankar, Wudbhav N

    2014-12-01

    Closed reduction (CR) and spica casting is performed using arthrography to assess the adequacy of reduction based in part on the width of medial dye pool (MDP); however, the amount of MDP that is acceptable and its correlation to the actual anatomic position of the femoral head within the acetabulum has been poorly delineated. The purpose of this study was to determine this correlation and to explore the potential limits of acceptable MDP measurements. We retrospectively reviewed a consecutive series of patients with DDH treated at our institution by CR and immediate postoperative magnetic resonance imaging (MRI) and found 20 patients (23 hips) meeting inclusion criteria. We measured the MDP and femoral head area on the best reduced arthrographic image, the immediate postoperative mid-coronal MRI, and on 3 planes (neutral, 30-degree anterior, and 30-degree posterior) of the mid-axial MRI and compared MDP values from both imaging modalities using the Pearson correlation coefficient (R). To provide useful data for establishing intraoperative thresholds, MDP was also expressed as a percentage of femoral head width to control for fluoroscopic magnification. Twenty-two of the 23 hips were reduced on postoperative MRI; the one persistently dislocated hip was excluded from our analysis. The Pearson correlation coefficient was R = 0.73 comparing arthrography and coronal MRI, indicating excellent correlation. Correlation was even stronger between arthrography and axial MRI (neutral R = 0.73; 30-degree anterior, R = 0.81; 30-degree posterior, R = 0.81). The mean fluoroscopic MDP in the successful, fully concentric, CRs was 4.2% of the femoral head width (range, 0.6% to 15.8%). There is very strong correlation between MDP measurements on arthrography and immediate postoperative MRI in both the axial and coronal planes. On the basis of our data, an arthrographic MDP between 0.6% and 15.8% of the femoral head width always resulted in an excellent reduction, suggesting that an MDP of ≤ 16% of femoral head width may be a useful intraoperative criterion for determining the adequacy of CR. Level I Diagnostic Study.

  8. Central Corneal Thickness Reproducibility among Ten Different Instruments.

    PubMed

    Pierro, Luisa; Iuliano, Lorenzo; Gagliardi, Marco; Ambrosi, Alessandro; Rama, Paolo; Bandello, Francesco

    2016-11-01

    To assess agreement between one ultrasonic (US) and nine optical instruments for the measurement of central corneal thickness (CCT), and to evaluate intra- and inter-operator reproducibility. In this observational cross-sectional study, two masked operators measured CCT thickness twice in 28 healthy eyes. We used seven spectral-domain optical coherence tomography (SD-OCT) devices, one time-domain OCT, one Scheimpflug camera, and one US-based instrument. Inter- and intra-operator reproducibility was evaluated by intraclass correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman test analysis. Instrument-to-instrument reproducibility was determined by ANOVA for repeated measurements. We also tested how the devices disagreed regarding systemic bias and random error using a structural equation model. Mean CCT of all instruments ranged from 536 ± 42 μm to 577 ± 40 μm. An instrument-to-instrument correlation test showed high values among the 10 investigated devices (correlation coefficient range 0.852-0.995; p values <0.0001 in all cases). The highest correlation coefficient values were registered between 3D OCT-2000 Topcon-Spectral OCT/SLO Opko (0.995) and Cirrus HD-OCT Zeiss-RS-3000 Nidek (0.995), whereas the lowest were seen between SS-1000 CASIA and Spectral OCT/SLO Opko (0.852). ICC and CV showed excellent inter- and intra-operator reproducibility for all optic-based devices, except for the US-based device. Bland-Altman analysis demonstrated low mean biases between operators. Despite highlighting good intra- and inter-operator reproducibility, we found that a scale bias between instruments might interfere with thorough CCT monitoring. We suggest that optimal monitoring is achieved with the same operator and the same device.

  9. Measurement of the perfusion fraction in brain tumors with intravoxel incoherent motion MR imaging: validation with histopathological vascular density in meningiomas.

    PubMed

    Togao, Osamu; Hiwatashi, Akio; Yamashita, Koji; Kikuchi, Kazufumi; Momosaka, Daichi; Yoshimoto, Koji; Kuga, Daisuke; Mizoguchi, Masahiro; Suzuki, Satoshi O; Iwaki, Toru; Van Cauteren, Marc; Iihara, Koji; Honda, Hiroshi

    2018-05-01

    To evaluate the quantification performance of the perfusion fraction (f) measured with intravoxel incoherent motion (IVIM) MR imaging in a comparison with the histological vascular density in meningiomas. 29 consecutive patients with meningioma (59.0 ± 16.8 years old, 8 males and 21 females) who underwent a subsequent surgical resection were examined with both IVIM imaging and a histopathological analysis. IVIM imaging was conducted using a single-shot SE-EPI sequence with 13 b-factors (0, 10, 20, 30, 50, 80, 100, 200, 300, 400, 600, 800, 1000 s mm - 2 ) at 3T. The perfusion fraction (f) was calculated by fitting the IVIM bi-exponential model. The 90-percentile f-value in the tumor region-of-interest (ROI) was defined as the maximum f-value (f-max). Histopathological vascular density (%Vessel) was measured on CD31-immunostainted histopathological specimens. The correlation and agreement between the f-values and %Vessel was assessed. The f-max (15.5 ± 5.5%) showed excellent agreement [intraclass correlation coefficient (ICC) = 0.754] and a significant correlation (r = 0.69, p < 0.0001) with the %Vessel (12.9 ± 9.4%) of the tumors. The Bland-Altman plot analysis showed excellent agreement between the f-max and %Vessel (bias, -2.6%; 95% limits of agreement, from -16.0 to 10.8%). The f-max was not significantly different among the histological subtypes of meningioma. An excellent agreement and a significant correlation were observed between the f-values and %Vessel. The f-value can be used as a noninvasive quantitative imaging measure to directly assess the vascular volume fraction in brain tumors. Advances in knowledge: The f-value measured by IVIM imaging showed a significant correlation and an excellent agreement with the histological vascular density in the meningiomas. The f-value can be used as a noninvasive and quantitative imaging measure to directly assess the volume fraction of capillaries in brain tumors.

  10. Reliability, validity, and responsiveness of the Japanese version of the Patient-Rated Wrist Evaluation.

    PubMed

    Imaeda, Toshihiko; Uchiyama, Shigeharu; Wada, Takuro; Okinaga, Shuji; Sawaizumi, Takuya; Omokawa, Shohei; Momose, Toshimitsu; Moritomo, Hisao; Gotani, Hiroyuki; Abe, Yukio; Nishida, Jun; Kanaya, Fuminori

    2010-07-01

    The Patient-Rated Wrist Evaluation is a regionspecific, self-administered questionnaire consisting of a pain scale (PRWE-P) and a functional scale (PRWE-F), with the latter consisting of specific function (PRWE-SF) and usual function (PRWE-UF). The PRWE was cross-culturally adapted from the original English version by the Impairment Evaluation Committee, Japanese Society for Surgery of the Hand (JSSH). The purpose of this study was to test the reliability, validity, and responsiveness of the Japanese version of PRWE (PRWE-J). A consecutive series of 117 patients with wrist disorders completed the PRWE-J, the JSSH version of the Disabilities of the Arm, Shoulder, and Hand (DASH-JSSH) questionnaire and the 36-Item Short-Form Health Survey (SF-36). Of the 117 patients, 71 were reassessed for test-retest reliability 1 or 2 weeks later. Reliability was investigated by reproducibility and internal consistency. To analyze the validity, a factor analysis (principal axis factoring) of PRWE-J and correlation coefficients between PRWE-J and DASH-JSSH were obtained. Responsiveness was examined by calculating the standardized response mean (SRM) (mean change/SD) and effect size (mean change/SD of baseline value) after open surgery in 50 patients. Cronbach's alpha coefficients for PRWE-P, PRWE-F, and PRWE were 0.90, 0.95, and 0.95, respectively. The intraclass correlation coefficients (ICCs) for the same were 0.86, 0.93, and 0.92, respectively. Unidimensionality of PRWE-P was con-firmed. Bidimensionality of PRWE-F was confirmed and separated clearly into PRWE-SF and PRWE-UF. The correlation coefficients between PRWE-P and PRWE-F or DASH-JSSH were 0.63 or 0.63, respectively. The correlation coefficient between PRWE-F and DASH-JSSH was 0.80. The correlation coefficients between DASH-JSSH and PRWE-SF or PRWE-UF were 0.76 or 0.73, respectively. Moderate correlation was observed in "physical functioning" for SF-36 and PRWE-SF (r = -0.46), PRWE-F (r = -0.46), or PRWE (r = -0.46). The SRMs/effect sizes of PRWE-P, PRWE-F, or PRWE were respectively excellent: 1.7/2.2, 1.2/1.3, 1.6/1.9. The PRWE-J has evaluation capacities equivalent to those of the original PRWE.

  11. Development of anodic titania nanotubes for application in high sensitivity amperometric glucose and uric acid biosensors.

    PubMed

    Lee, Hsiang-Ching; Zhang, Li-Fan; Lin, Jyh-Ling; Chin, Yuan-Lung; Sun, Tai-Ping

    2013-10-21

    The purpose of this study was to develop novel nanoscale biosensors using titania nanotubes (TNTs) made by anodization. Titania nanotubes were produced on pure titanium sheets by anodization at room temperature. In this research, the electrolyte composition ethylene glycol 250 mL/NH4F 1.5 g/DI water 20 mL was found to produce the best titania nanotubes array films for application in amperometric biosensors. The amperometric results exhibit an excellent linearity for uric acid (UA) concentrations in the range between 2 and 14 mg/dL, with 23.3 (µA·cm-2)·(mg/dL)-1 UA sensitivity, and a correlation coefficient of 0.993. The glucose biosensor presented a good linear relationship in the lower glucose concentration range between 50 and 125 mg/dL, and the corresponding sensitivity was approximately 249.6 (µA·cm-2)·(100 mg/dL)-1 glucose, with a correlation coefficient of 0.973.

  12. Translation, Cultural Adaptation and Validation of the Simple Shoulder Test to Spanish

    PubMed Central

    Arcuri, Francisco; Barclay, Fernando; Nacul, Ivan

    2015-01-01

    Background: The validation of widely used scales facilitates the comparison across international patient samples. Objective: The objective was to translate, culturally adapt and validate the Simple Shoulder Test into Argentinian Spanish. Methods: The Simple Shoulder Test was translated from English into Argentinian Spanish by two independent translators, translated back into English and evaluated for accuracy by an expert committee to correct the possible discrepancies. It was then administered to 50 patients with different shoulder conditions.Psycometric properties were analyzed including internal consistency, measured with Cronbach´s Alpha, test-retest reliability at 15 days with the interclass correlation coefficient. Results: The internal consistency, validation, was an Alpha of 0,808, evaluated as good. The test-retest reliability index as measured by intra-class correlation coefficient (ICC) was 0.835, evaluated as excellent. Conclusion: The Simple Shoulder Test translation and it´s cultural adaptation to Argentinian-Spanish demonstrated adequate internal reliability and validity, ultimately allowing for its use in the comparison with international patient samples.

  13. Validity of the Nintendo Wii® balance board for the assessment of standing balance in Parkinson's disease.

    PubMed

    Holmes, Jeffrey D; Jenkins, Mary E; Johnson, Andrew M; Hunt, Michael A; Clark, Ross A

    2013-04-01

    Impaired postural stability places individuals with Parkinson's at an increased risk for falls. Given the high incidence of fall-related injuries within this population, ongoing assessment of postural stability is important. To evaluate the validity of the Nintendo Wii(®) balance board as a measurement tool for the assessment of postural stability in individuals with Parkinson's. Twenty individuals with Parkinson's participated. Subjects completed testing on two balance tasks with eyes open and closed on a Wii(®) balance board and biomechanical force platform. Bland-Altman plots and a two-way, random-effects, single measure intraclass correlation coefficient model were used to assess concurrent validity of centre-of-pressure data. Concurrent validity was demonstrated to be excellent across balance tasks (intraclass correlation coefficients = 0.96, 0.98, 0.92, 0.94). This study suggests that the Wii(®) balance board is a valid tool for the quantification of postural stability among individuals with Parkinson's.

  14. Does Dry Eye Affect Repeatability of Corneal Topography Measurements?

    PubMed

    Doğan, Aysun Şanal; Gürdal, Canan; Köylü, Mehmet Talay

    2018-04-01

    The purpose of this study was to assess the repeatability of corneal topography measurements in dry eye patients and healthy controls. Participants underwent consecutive corneal topography measurements (Sirius; Costruzione Strumenti Oftalmici, Florence, Italy). Two images with acquisition quality higher than 90% were accepted. The following parameters were evaluated: minimum and central corneal thickness, aqueous depth, apex curvature, anterior chamber volume, horizontal anterior chamber diameter, iridocorneal angle, cornea volume, and average simulated keratometry. Repeatability was assessed by calculating intra-class correlation coefficient. Thirty-three patients with dry eye syndrome and 40 healthy controls were enrolled to the study. The groups were similar in terms of age (39 [18-65] vs. 30.5 [18-65] years, p=0.198) and gender (M/F: 4/29 vs. 8/32, p=0.366). Intra-class correlation coefficients among all topography parameters within both groups showed excellent repeatability (>0.90). The anterior segment measurements provided by the Sirius corneal topography system were highly repeatable for dry eye patients and are sufficiently reliable for clinical practice and research.

  15. Scaling digital radiographs for templating in total hip arthroplasty using conventional acetate templates independent of calibration markers.

    PubMed

    Brew, Christopher J; Simpson, Philip M; Whitehouse, Sarah L; Donnelly, William; Crawford, Ross W; Hubble, Matthew J W

    2012-04-01

    We describe a scaling method for templating digital radiographs using conventional acetate templates independent of template magnification without the need for a calibration marker. The mean magnification factor for the radiology department was determined (119.8%; range, 117%-123.4%). This fixed magnification factor was used to scale the radiographs by the method described. Thirty-two femoral heads on postoperative total hip arthroplasty radiographs were then measured and compared with the actual size. The mean absolute accuracy was within 0.5% of actual head size (range, 0%-3%) with a mean absolute difference of 0.16 mm (range, 0-1 mm; SD, 0.26 mm). Intraclass correlation coefficient showed excellent reliability for both interobserver and intraobserver measurements with intraclass correlation coefficient scores of 0.993 (95% CI, 0.988-0.996) for interobserver measurements and intraobserver measurements ranging between 0.990 and 0.993 (95% CI, 0.980-0.997). Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.

  16. Development of Anodic Titania Nanotubes for Application in High Sensitivity Amperometric Glucose and Uric Acid Biosensors

    PubMed Central

    Lee, Hsiang-Ching; Zhang, Li-Fan; Lin, Jyh-Ling; Chin, Yuan-Lung; Sun, Tai-Ping

    2013-01-01

    The purpose of this study was to develop novel nanoscale biosensors using titania nanotubes (TNTs) made by anodization. Titania nanotubes were produced on pure titanium sheets by anodization at room temperature. In this research, the electrolyte composition ethylene glycol 250 mL/NH4F 1.5 g/DI water 20 mL was found to produce the best titania nanotubes array films for application in amperometric biosensors. The amperometric results exhibit an excellent linearity for uric acid (UA) concentrations in the range between 2 and 14 mg/dL, with 23.3 (μA·cm−2)·(mg/dL)−1 UA sensitivity, and a correlation coefficient of 0.993. The glucose biosensor presented a good linear relationship in the lower glucose concentration range between 50 and 125 mg/dL, and the corresponding sensitivity was approximately 249.6 (μA·cm−2)·(100 mg/dL)−1 glucose, with a correlation coefficient of 0.973. PMID:24152934

  17. Reliability of Neurobehavioral Assessments from Birth to Term Equivalent Age in Preterm and Term Born Infants.

    PubMed

    Eeles, Abbey L; Olsen, Joy E; Walsh, Jennifer M; McInnes, Emma K; Molesworth, Charlotte M L; Cheong, Jeanie L Y; Doyle, Lex W; Spittle, Alicia J

    2017-02-01

    Neurobehavioral assessments provide insight into the functional integrity of the developing brain and help guide early intervention for preterm (<37 weeks' gestation) infants. In the context of shorter hospital stays, clinicians often need to assess preterm infants prior to term equivalent age. Few neurobehavioral assessments used in the preterm period have established interrater reliability. To evaluate the interrater reliability of the Hammersmith Neonatal Neurological Examination (HNNE) and the NICU Network Neurobehavioral Scale (NNNS), when used both preterm and at term (>36 weeks). Thirty-five preterm infants and 11 term controls were recruited. Five assessors double-scored the HNNE and NNNS administered either preterm or at term. A one-way random effects, absolute, single-measures interclass correlation coefficient (ICC) was calculated to determine interrater reliability. Interrater reliability for the HNNE was excellent (ICC > 0.74) for optimality scores, and good (ICC 0.60-0.74) to excellent for subtotal scores, except for 'Tone Patterns' (ICC 0.54). On the NNNS, interrater reliability was predominantly excellent for all items. Interrater agreement was generally excellent at both time points. Overall, the HNNE and NNNS neurobehavioral assessments demonstrated mostly excellent interrater reliability when used prior to term and at term.

  18. Whole lesion histogram analysis of meningiomas derived from ADC values. Correlation with several cellularity parameters, proliferation index KI 67, nucleic content, and membrane permeability.

    PubMed

    Surov, Alexey; Hamerla, Gordian; Meyer, Hans Jonas; Winter, Karsten; Schob, Stefan; Fiedler, Eckhard

    2018-09-01

    To analyze several histopathological features and their possible correlations with whole lesion histogram analysis derived from ADC maps in meningioma. The retrospective study involved 36 patients with primary meningiomas. For every tumor, the following histogram analysis parameters of apparent diffusion coefficient (ADC) were calculated: ADC mean , ADC max , ADC min , ADC median , ADC mode , ADC percentiles: P10, P25, P75, P90, as well kurtosis, skewness, and entropy. All measures were performed by two radiologists. Proliferation index KI 67, minimal, maximal and mean cell count, total nucleic area, and expression of water channel aquaporin 4 (AQP4) were estimated. Spearman's correlation coefficient was used to analyze associations between investigated parameters. A perfect interobserver agreement for all ADC values (0.84-0.97) was identified. All ADC values correlated inversely with tumor cellularity with the strongest correlation between P10, P25 and mean cell count (-0.558). KI 67 correlated inversely with all ADC values except ADC min . ADC parameters did not correlate with total nucleic area. All ADC values correlated statistically significant with expression of AQP4. ADC histogram analysis is a valid method with an excellent interobserver agreement. Cellularity parameters and proliferation potential are associated with different ADC values. Membrane permeability may play a greater role for water diffusion than cell count and proliferation activity. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. The Children's Play Therapy Instrument (CPTI). Description, development, and reliability studies.

    PubMed

    Kernberg, P F; Chazan, S E; Normandin, L

    1998-01-01

    The Children's Play Therapy Instrument (CPTI), its development, and reliability studies are described. The CPTI is a new instrument to examine a child's play activity in individual psychotherapy. Three independent raters used the CPTI to rate eight videotaped play therapy vignettes. Results were compared with the authors' consensual scores from a preliminary study. Generally good to excellent levels of interrater reliability were obtained for the independent raters on intraclass correlation coefficients for ordinal categories of the CPTI. Likewise, kappa levels were acceptable to excellent for nominal categories of the scale. The CPTI holds promise to become a reliable measure of play activity in child psychotherapy. Further research is needed to assess discriminant validity of the CPTI for use as a diagnostic tool and as a measure of process and outcome.

  20. Reliability, Validity, and Sensitivity to Change Overtime of the Modified Melasma Area and Severity Index Score.

    PubMed

    Abou-Taleb, Doaa A E; Ibrahim, Ahmed K; Youssef, Eman M K; Moubasher, Alaa E A

    2017-02-01

    The new modified Melasma Area and Severity Index (mMASI) score, the recently used outcome measure for melasma, has not been tested to determine its sensitivity to change in melasma. To determine the reliability, validity, and sensitivity to change overtime of the mMASI score in assessment of the severity of melasma. Pearson correlation, Cronbach alpha, and intraclass correlation coefficient were calculated to assess the reliability of the mMASI score. Validity of the mMASI scale was carried out using Spearman correlation between mMASI total score (before and after treatment), clinical data, and patient's responses. The mMASI score showed excellent reliability and good validity for assessment of the severity of melasma. The authors also determined that the mMASI score demonstrated sensitivity to change over time. An excellent degree of agreement between the mMSAI and MASI scores was revealed. The mMASI score is reliable, valid, and responsive to change in the assessment of severity of melasma. Moreover, the mMASI score was found to be easier to learn and perform and simpler in calculation compared with the MASI score. Overall, the mMASI score can effectively replace the MASI score.

  1. High inter-rater reliability, agreement, and convergent validity of Constant score in patients with clavicle fractures.

    PubMed

    Ban, Ilija; Troelsen, Anders; Kristensen, Morten Tange

    2016-10-01

    The Constant score (CS) has been the primary endpoint in most studies on clavicle fractures. However, the CS was not developed to assess patients with clavicle fractures. Our aim was to examine inter-rater reliability and agreement of the CS in patients with clavicle fractures. The secondary aim was to estimate the correlation between the CS and the Disabilities of the Arm, Shoulder and Hand score and the internal consistency of the 2 scores. On the basis of sample sizing, 36 patients (31 male and 5 female patients; mean age, 41.3 years) with clavicle fractures underwent standardized CS assessment at a mean of 6.8 weeks (SD, 1.0 weeks) after injury. Reliability and agreement of the CS were determined by 2 raters. The interclass correlation coefficient (ICC2,1), standard error of measurement, minimal detectable change, Cronbach α coefficient, and Pearson correlation coefficient were estimated. Inter-rater reliability of the total CS was excellent (interclass correlation coefficient, 0.94; 95% confidence interval, 0.88-0.97), with no systematic difference between the 2 raters (P = .75). The standard error of measurement (measurement error at the group level) was 4.9, whereas the minimal detectable change (smallest change needed to indicate a real change for an individual) was 13.6 CS points. The internal consistency of the 10 CS items was good, with a Cronbach α of .85, and we found a strong correlation (r = -0.92) between the CS and Disabilities of the Arm, Shoulder and Hand score. The CS was found to be reliable for assessing patients with clavicle fractures, especially at the group level. With high inter-rater reliability and agreement, in addition to good internal consistency, the standardized CS used in this study can be used for comparison of results from different settings. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  2. Translation and Cross-cultural Adaptation of the Hip Disability and Osteoarthritis Score into Persian Language: Reassessment of Validity and Reliability

    PubMed Central

    Mousavian, Alireza; Kachooie, Amir Reza; Birjandinejad, Ali; Khoshsaligheh, Masood; Ebrahimzadeh, Mohammad Hosein

    2018-01-01

    Background: This study aimed Persian translation and validation of the hip disability and osteoarthritis outcome score (HOOS) questionnaire. Methods: The study was carried out in two phases. First, we translated the HOOS according to acceptable guidelines. We assessed HOOS content convergent validity on 203 hip osteoarthritis patients using SF-36. Internal consistency was tested using Cronbach's alpha coefficient if each item removed and intraclass correlation coefficient (ICC) for the assessment of test-retest reproducibility. Results: Patients had mean (standard deviation) age of 39 (17). Test-retest ICC in whole was 0.95 (P = 0.014) showing excellent reliability. ICC was 0.92 for the “pain” subscale (P = 0.02), 0.81 for the “symptom” subscale (P = 0.002), 0.81 for the “function of daily living (FDL)” (P = 0.022), 0.88 for the “function of sports and recreational activities” (P = 0.006), but it was 0.62 (P = 0.1) for the “quality of life (QOL).” Cronbach's alpha was 0.92, 0.73, 0.97, 0.86, 0.80, and 0.80 for the pain, symptom, FDL, function of sports, QOL, and stiffness, respectively, showing good to excellent internal consistancy. Having SF-36 for the assessment of convergent validity, there was a strong correlation between total HOOS score and the physical component summary domain of SF-36 (r = 0.64, P = 0.0001), whereas the t correlation with the mental component summary domain was weak (r = 0.16, P = 0.04). Conclusions: The Persian version of the HOOS questionnaire is a valid (regarding physical not mental aspects) and reliable assessment tool in patients with hip osteoarthritis. PMID:29619147

  3. Efficiency and measurements agreement between swept-source OCT and low-coherence interferometry biometry systems.

    PubMed

    Calvo-Sanz, Jorge A; Portero-Benito, Alejandro; Arias-Puente, Alfonso

    2018-03-01

    To compare and evaluate the agreement between the measurements obtained with a swept-source optical coherence tomography (OCT)-based biometer, the IOLMaster® 700 (IOLM), and those obtained by an optical biometer based on optical low-coherence interferometry (OLCI), the Aladdin (ALD); To evaluate the ability to perform biometric measurements in those eyes with transparency alterations. Fifty-five eyes of 55 subjects were included in this study. Axial length (AL), corneal power (K, in diopters) and its astigmatism, anterior chamber depth (ACD), central corneal thickness (CCT), and lens thickness (LT) measures were obtained within both biometers, Zeiss IOLMaster 700 and Topcon Aladdin. Results were analyzed and compared using the Student's paired samples t-test, Bland-Altman analysis and intraclass correlation coefficient (ICC). Mean age was 73.12 ± 2.63 (62-89 years). The IOLM mean AL, K, and LT values did not show a statistically significant difference from ALD values and showed excellent agreement and correlation (ICC = 1.000, 0.970, 0.952). IOLM measured a lower mean ACD (-0.036 mm) and higher CCT measurements (9.296 μm). Those results were statistically different (p < 0.001 in both cases) but showed an excellent correlation coefficients (ICC = 0.994, 0.938). IOLM was able to obtain measures from all the eyes examined, while ALD did not measure in two cases with dense nuclear cataract. ALD showed spherical K measures in 7.27% of cases. Overall a quite good agreement between IOLM and ALD was found. ALD showed spherical keratometry measures in 7.27% of cases. IOLMaster 700 was more effective in obtaining AL measurements in eyes with dense cataracts.

  4. The feasibility of measuring renal blood flow using transesophageal echocardiography in patients undergoing cardiac surgery.

    PubMed

    Yang, Ping-Liang; Wong, David T; Dai, Shuang-Bo; Song, Hai-Bo; Ye, Ling; Liu, Jin; Liu, Bin

    2009-05-01

    There is no reliable method to monitor renal blood flow intraoperatively. In this study, we evaluated the feasibility and reproducibility of left renal blood flow measurements using transesophageal echocardiography during cardiac surgery. In this prospective noninterventional study, left renal blood flow was measured with transesophageal echocardiography during three time points (pre-, intra-, and postcardiopulmonary bypass) in 60 patients undergoing cardiac surgery. Sonograms from 6 subjects were interpreted by 2 blinded independent assessors at the time of acquisition and 6 mo later. Interobserver and intraobserver reproducibility were quantified by calculating variability and intraclass correlation coefficients. Patients with Doppler angles of >30 degrees (20 of 60 subjects) were eliminated from renal blood flow measurements. Left renal blood flow was successfully measured and analyzed in 36 of 60 (60%) subjects. Both interobserver and intraobserver variability were <10%. Interobserver and intraobserver reproducibility in left renal blood flow measurements were good to excellent (intraclass correlation coefficients 0.604-0.999). Left renal arterial luminal diameter for the pre, intra, and postcardiopulmonary bypass phases, ranged from 3.8 to 4.1 mm, renal arterial velocity from 25 to 35 cm/s, and left renal blood flow from 192 to 299 mL/min. In patients undergoing cardiac surgery, it was feasible in 60% of the subjects to measure left renal blood flow using intraoperative transesophageal echocardiography. The interobserver and intraobserver reproducibility of renal blood flow measurements was good to excellent.

  5. Validation of Spanish versions of the Pelvic Floor Distress Inventory (PFDI) and Pelvic Floor Impact Questionnaire (PFIQ): a multicenter validation randomized study.

    PubMed

    Omotosho, Tola B; Hardart, Anne; Rogers, Rebecca G; Schaffer, Joseph I; Kobak, William H; Romero, Audrey A

    2009-06-01

    The purpose of this study is to validate Spanish versions of the Pelvic Floor Distress Inventory (PFDI) and Pelvic Floor Impact Questionnaire (PFIQ). Spanish versions were developed using back translation and validation was performed by randomizing bilingual women to complete the Spanish or English versions of the questionnaires first. Weighted kappa statistics assessed agreement for individual questions; interclass correlation coefficients (ICC) compared primary and subscale scores. Cronbach's alpha assessed internal consistency of Spanish versions. To detect a 2.7 point difference in scores with 80% power and alpha of 0.05, 44 bilingual subjects were required. Individual questions showed good to excellent agreement (kappa > 0.6) for all but eight questions on the PFIQ. ICCs of primary and subscale scores for both questionnaires showed excellent agreement. (All ICC > 0.79). All Cronbach's alpha values were excellent (>0.84) for the primary scales of both questionnaires. Valid and reliable Spanish versions of the PFIQ and PFDI have been developed.

  6. Correlation and Reliability of Cervical Sagittal Alignment Parameters between Lateral Cervical Radiograph and Lateral Whole-Body EOS Stereoradiograph.

    PubMed

    Singhatanadgige, Weerasak; Kang, Daniel G; Luksanapruksa, Panya; Peters, Colleen; Riew, K Daniel

    2016-09-01

    Retrospective analysis. To evaluate the correlation and reliability of cervical sagittal alignment parameters obtained from lateral cervical radiographs (XRs) compared with lateral whole-body stereoradiographs (SRs). We evaluated adults with cervical deformity using both lateral XRs and lateral SRs obtained within 1 week of each other between 2010 and 2014. XR and SR images were measured by two independent spine surgeons using the following sagittal alignment parameters: C2-C7 sagittal Cobb angle (SCA), C2-C7 sagittal vertical axis (SVA), C1-C7 translational distance (C1-7), T1 slope (T1-S), neck tilt (NT), and thoracic inlet angle (TIA). Pearson correlation and paired t test were used for statistical analysis, with intra- and interrater reliability analyzed using intraclass correlation coefficient (ICC). A total of 35 patients were included in the study. We found excellent intrarater reliability for all sagittal alignment parameters in both the XR and SR groups with ICC ranging from 0.799 to 0.994 for XR and 0.791 to 0.995 for SR. Interrater reliability was also excellent for all parameters except NT and TIA, which had fair reliability. We also found excellent correlations between XR and SR measurements for most sagittal alignment parameters; SCA, SVA, and C1-C7 had r > 0.90, and only NT had r < 0.70. There was a significant difference between groups, with SR having lower measurements compared with XR for both SVA (0.68 cm lower, p < 0.001) and C1-C7 (1.02 cm lower, p < 0.001). There were no differences between groups for SCA, T1-S, NT, and TIA. Whole-body stereoradiography appears to be a viable alternative for measuring cervical sagittal alignment parameters compared with standard radiography. XR and SR demonstrated excellent correlation for most sagittal alignment parameters except NT. However, SR had significantly lower average SVA and C1-C7 measurements than XR. The lower radiation exposure using single SR has to be weighed against its higher cost compared with XR.

  7. Assessing self-reported disability in a low-literate population with chronic low back pain: cross-cultural adaptation and psychometric testing of Igbo Roland Morris disability questionnaire.

    PubMed

    Igwesi-Chidobe, Chinonso N; Obiekwe, Chinwe; Sorinola, Isaac O; Godfrey, Emma L

    2017-12-14

    Cross-culturally adapt and validate the Igbo Roland Morris Disability Questionnaire. Cross-cultural adaptation, test-retest, and cross-sectional psychometric testing. Roland Morris Disability Questionnaire was forward and back translated by clinical/non-clinical translators. An expert committee appraised the translations. Twelve participants with chronic low back pain pre-tested the measure in a rural Nigerian community. Internal consistency using Cronbach's alpha; test-retest reliability using intra-class correlation coefficient and Bland-Altman plot; and minimal detectable change were investigated in a convenient sample of 50 people with chronic low back pain in rural and urban Nigeria. Pearson's correlation analyses using the eleven-point box scale and back performance scale, and exploratory factor analysis were used to examine construct validity in a random sample of 200 adults with chronic low back pain in rural Nigeria. Ceiling and floor effects were investigated in the two samples. Modifications gave the option of interviewer-administration and reflected Nigerian social context. The measure had excellent internal consistency (α = 0.91) and intraclass correlation coefficient (ICC =0.84), moderately high correlations (r > 0.6) with performance-based disability and pain intensity, and a predominant uni-dimensional structure, with no ceiling or floor effects. Igbo Roland Morris Disability Questionnaire is a valid and reliable measure of pain-related disability. Implications for rehabilitation Low back pain is the leading cause of years lived with disability worldwide, and is particularly prevalent in rural Nigeria, but there are no self-report measures to assess its impact due to low literacy rates. This study describes the cross-cultural adaptation and validation of a core self-report back pain specific disability measure in a low-literate Nigerian population. The Igbo Roland Morris Disability Questionnaire is a reliable and valid measure of self-reported disability in Igbo populations as indicated by excellent internal consistency (α = 0.91) and intra-class correlation coefficient (ICC =0.84), moderately high correlations (r > 0.6) with performance-based disability and pain intensity that supports a pain-related disability construct, a predominant one factor structure with no ceiling or floor effects. The measure will be useful for researchers and clinicians examining the factors associated with low back pain disability or the effects of interventions on low back pain disability in this culture. This measure will support global health initiatives concurrently involving people from several cultures or countries, and may inform cross-cultural disability research in other populations.

  8. An empirical relation between the limiting ionic molar conductivities and self-diffusion coefficients of pure solvents

    NASA Astrophysics Data System (ADS)

    Matsuyama, Hisashi; Motoyoshi, Kota

    2018-05-01

    The limiting ionic molar conductivity (λ∞) of an electrolyte solution depends on the self-diffusion coefficient (Ds) of the pure solvent when the temperature (T) changes. To study the Ds-dependence of λ∞, we proposed a new empirical relation λ∞ ∝(Ds / T) t , with a parameter t. The relation is applied to the λ∞ and Ds of alkali, tetra-alkyl ammonium, and halogen ions in water or methanol. All ions except for tetra-alkyl ammonium ions in water exhibit excellent linear relationships in their λ∞ ∝(Ds / T) t plots, with t in the range from 0.88 to 1.26. This is the first report showing an affirmative linear correlation between λ∞ and Ds.

  9. Novel Spectrophotometric Method for the Quantitation of Urinary Xanthurenic Acid and Its Application in Identifying Individuals with Hyperhomocysteinemia Associated with Vitamin B6 Deficiency

    PubMed Central

    Chen, Chi-Fen; Liu, Tsan-Zon; Lan, Wu-Hsiang; Wu, Li-An; Tsai, Chin-Hung; Chiou, Jeng-Fong; Tsai, Li-Yu

    2013-01-01

    A novel spectrophotometric method for the quantification of urinary xanthurenic acid (XA) is described. The direct acid ferric reduction (DAFR) procedure was used to quantify XA after it was purified by a solid-phase extraction column. The linearity of proposed method extends from 2.5 to 100.0 mg/L. The method is precise, yielding day-to-day CVs for two pooled controls of 3.5% and 4.6%, respectively. Correlation studies with an established HPLC method and a fluorometric procedure showed correlation coefficients of 0.98 and 0.98, respectively. Interference from various urinary metabolites was insignificant. In a small-scale screening of elderly conducted at Penghu county in Taiwan (n = 80), we were able to identify a group of twenty individuals having hyperhomocysteinemia (>15 μmole/L). Three of them were found to be positive for XA as analyzed by the proposed method, which correlated excellently with the results of the activation coefficient method for RBC's AST/B6 functional test. These data confirm the usefulness of the proposed method for identifying urinary XA as an indicator of vitamin B6 deficiency-associated hyperhomocysteinemic condition. PMID:24151616

  10. Bony defects in chronic anterior posttraumatic dislocation of the shoulder: Is there a correlation between humeral and glenoidal lesions?

    PubMed

    Ciais, Grégoire; Klouche, Shahnaz; Fournier, Alexandre; Rousseau, Benoit; Bauer, Thomas; Hardy, Philippe

    2016-08-01

    The prevalence of combined humeral and glenoid defects varies between 79 and 84 % in case of chronic posttraumatic anterior shoulder instability. The main goal of this study was to evaluate the relationship between humeral and glenoid defects based on quantitative radiological criteria. A retrospective study was performed between 2000 and 2011 including patients who underwent primary surgical shoulder stabilization for chronic posttraumatic anterior shoulder instability, with bone defects in both the glenoid and humerus and a healthy contralateral shoulder. The following measurements were taken: D/R ratio (Hill-Sachs lesion depth/humeral head radius) on an AP X-ray in internal rotation and the D1/D2 ratio [diameter of the involved glenoid articular surfaces (D1)/the healthy one (D2)] on a comparative Bernageau glenoid profile view. Measurements were taken by two observers. Correlations were determined by the Spearman correlation coefficients (r), Bland and Altman diagrams, and intra-class correlation coefficients (ICC). A sample size calculation was done. Thirty patients were included, 25 men/5 women, mean age 29.8 ± 11.2 years. The mean D/R was 23 ± 12 % for observer 1 and 23 ± 10 % for observer 2. The mean D1/D2 was 95 ± 4 % for observer 1 and 94 ± 6 % for observer 2. No significant correlation was found between humeral and glenoid bone defects by observer 1 (r = 0.23, p = 0.22) or observer 2 (r = 0.05, p = 0.78). Agreement of the observers for the D/R ratio was excellent (ICC = 0.89 ± 0.04, p < 0.00001) and good for the D1/D2 ratio (ICC = 0.54 ± 0.14, p = 0.006). Humeral and glenoid bone defects were not correlated. Inter-observer reliability was excellent for the D/R ratio and good for the D1/D2 ratio. Nonconsecutive Patients, Diagnostic Study, Level III.

  11. Test-retest reliability of automated whole body and compartmental muscle volume measurements on a wide bore 3T MR system.

    PubMed

    Thomas, Marianna S; Newman, David; Leinhard, Olof Dahlqvist; Kasmai, Bahman; Greenwood, Richard; Malcolm, Paul N; Karlsson, Anette; Rosander, Johannes; Borga, Magnus; Toms, Andoni P

    2014-09-01

    To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI. Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes. Mean automated total body muscle volume was 19·32 L (SD9·1) and 19·28 L (SD9·12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1·0, 95% level of agreement -0·32-0·2 L). ICC for all automated test-retest muscle volumes were almost perfect (0·99-1·0) with 95% levels of agreement 1.8-6.6% of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1·68 L (2SD0·6) compared to automated 1·64 L (2SD 0·6), left lower leg: manual 1·69 L (2SD 0·64) compared to automated 1·63 L (SD0·61), correlation coefficients for automated and manual segmentation were 0·94-0·96). Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg. Sarcopaenia is an important reversible complication of a number of diseases. Manual quantification of muscle volume is time-consuming and expensive. Muscles can be imaged using in and out of phase MRI. Automated atlas-based segmentation can identify muscle groups. Automated muscle volume segmentation is reproducible and can replace manual measurements.

  12. Translation, Cross-cultural Adaptation and Validation of the Farsi Version of NIH Task Force's Recommended Multidimensional Minimal Dataset for Research on Chronic Low Back Pain.

    PubMed

    Noormohammadpour, Pardis; Tavana, Bahareh; Mansournia, Mohammad Ali; Zeinalizadeh, Mehdi; Mirzashahi, Babak; Rostami, Mohsen; Kordi, Ramin

    2018-05-01

    Translation and cultural adaptation of the National Institutes of Health (NIH) Task Force's minimal dataset. The purpose of this study was to evaluate validity and reliability of the Farsi version of NIH Task Force's recommended multidimensional minimal dataset for research on chronic low back pain (CLBP). Considering the high treatment cost of CLBP and its increasing prevalence, NIH Pain Consortium developed research standards (including recommendations for definitions, a minimum dataset, and outcomes' report) for studies regarding CLBP. Application of these recommendations could standardize research and improve comparability of different studies in CLBP. This study has three phases: translation of dataset into Farsi and its cultural adaptation, assessment of pre-final version of dataset's comprehensibility via a pilot study, and investigation of the reliability and validity of final version of translated dataset. Subjects were 250 patients with CLBP. Test-retest reliability, content validity, and convergent validity (correlations among different dimensions of dataset and Farsi versions of Oswestry Disability Index, Roland Morris Disability Questionnaire, Fear-Avoidance Belief Questionnaire, and Beck Depression Inventory-II) were assessed. The Farsi version demonstrated good/excellent convergent validity (the correlation coefficient between impact dimension and ODI was r = 0.75 [P < 0.001], between impact dimension and Roland-Morris Disability Questionnaire was r = 0.80 [P < 0.001], and between psychological dimension and BDI was r = 0.62 [P < 0.001]). The test-retest reliability was also strong (intraclass correlation coefficient value ranged between 0.70 and 0.95) and the internal consistency was good/excellent (Chronbach's alpha coefficients' value for two main dimensions including impact dimension and psychological dimension were 0.91 and 0.82 [P < 0.001], respectively). In addition, its face validity and content validity were acceptable. The Farsi version of minimal dataset for research on CLBP is a reliable and valid instrument for data gathering in patients with CLBP. This minimum dataset can be a step toward standardization of research regarding CLBP. 3.

  13. Predicting the nodal status in gastric cancers: The role of apparent diffusion coefficient histogram characteristic analysis.

    PubMed

    Liu, Song; Zhang, Yujuan; Xia, Jie; Chen, Ling; Guan, Wenxian; Guan, Yue; Ge, Yun; He, Jian; Zhou, Zhengyang

    2017-10-01

    To explore the application of histogram analysis in preoperative T and N staging of gastric cancers, with a focus on characteristic parameters of apparent diffusion coefficient (ADC) maps. Eighty-seven patients with gastric cancers underwent diffusion weighted magnetic resonance imaging (b=0, 1000s/mm 2 ), which generated ADC maps. Whole-volume histogram analysis was performed on ADC maps and 7 characteristic parameters were obtained. All those patients underwent surgery and postoperative pathologic T and N stages were determined. Four parameters, including skew, kurtosis, s-sD av and sample number, showed significant differences among gastric cancers at different T and N stages. Most parameters correlated with T and N stages significantly and worked in differentiating gastric cancers at different T or N stages. Especially skew yielded a sensitivity of 0.758, a specificity of 0.810, and an area under the curve (AUC) of 0.802 for differentiating gastric cancers with and without lymph node metastasis (P<0.001). All the parameters, except AUC low , showed good or excellent inter-observer agreement with intra-class correlation coefficients ranging from 0.710 to 0.991. Characteristic parameters derived from whole-volume ADC histogram analysis could help assessing preoperative T and N stages of gastric cancers. Copyright © 2017. Published by Elsevier Inc.

  14. Test-retest reliability of the safe driving behavior measure for community-dwelling elderly drivers.

    PubMed

    Song, Chiang-Soon; Lee, Joo-Hyun; Han, Sang-Woo

    2016-06-01

    [Purpose] The Safe Driving Behavior Measure (SDBM) is a self-report measurement tools that assesses the safe-driving behaviors of the elderly. The purpose of this study was to evaluate the test-retest reliability of the SDBM among community-dwelling elderly drivers. [Subjects and Methods] A total of sixty-one community-dwelling elderly were enrolled to investigate the reliability of the SDBM. The SDBM was assessed in two sessions that were conducted three days apart in a quiet and well-organized assessment room. That test-retest reliability of overall scores and three domain scores of the SDBM were statistically evaluated using intraclass correlation coefficients [ICC (2.1)]. Pearson correlation coefficients were used to quantify bivariate associations among the three domains of the SDBM. [Results] The SDBM demonstrated excellent rest-retest reliability for community-dwelling elderly drivers. The Cronbach alpha coefficients of the three domains of person-vehicle (0.979), person-environment (0.944), and person-vehicle-environment (0.971) of the SDBM indicate high internal consistency. [Conclusion] The results of this study suggest that the SDBM is a reliable measure for evaluating the safe- driving of automobiles by community-dwelling elderly, and is adequate for detecting changes in scores in clinical settings.

  15. Reliability of the penetration aspiration scale with flexible endoscopic evaluation of swallowing.

    PubMed

    Butler, Susan G; Markley, Lisa; Sanders, Brian; Stuart, Andrew

    2015-06-01

    The Penetration Aspiration Scale (PAS), although designed for videofluoroscopy, has been utilized with flexible endoscopic evaluation of swallowing (FEES) in both research and clinical practice. The purpose of this investigation was to determine inter- and intrarater reliability of the PAS with FEES as a function of clinician FEES experience and retest interval. Three groups of 3 clinicians (N=9) with varying FEES experience (beginning, intermediate, and advanced) assigned PAS scores to 35 swallows. Initial ratings were repeated following short-term (ie, 1 day) and long-term (ie, 1 week) retest intervals. Intraclass correlation coefficients were calculated to assess interrater reliability on the first rating for each group. The coefficients were .91, .82, and .89 for the beginning, intermediate, and advanced clinicians, respectively. Overall interrater reliability across all 9 clinicians, irrespective of experience, was .85. Intraclass correlation coefficients were also calculated to assess intrarater reliability. The intrarater reliability for short- and long-term ratings was .90, .94, and .96 and .96, .97, and .94 for the beginning, intermediate, and advanced clinicians, respectively. Overall intrarater reliability across all 9 clinicians and all 3 ratings was .94. Excellent inter- and intrarater reliability was evidenced with the application of the PAS for FEES regardless of clinician experience and retest interval. © The Author(s) 2015.

  16. Apparent diffusion coefficient measurement in glioma: Influence of region-of-interest determination methods on apparent diffusion coefficient values, interobserver variability, time efficiency, and diagnostic ability.

    PubMed

    Han, Xu; Suo, Shiteng; Sun, Yawen; Zu, Jinyan; Qu, Jianxun; Zhou, Yan; Chen, Zengai; Xu, Jianrong

    2017-03-01

    To compare four methods of region-of-interest (ROI) placement for apparent diffusion coefficient (ADC) measurements in distinguishing low-grade gliomas (LGGs) from high-grade gliomas (HGGs). Two independent readers measured ADC parameters using four ROI methods (single-slice [single-round, five-round and freehand] and whole-volume) on 43 patients (20 LGGs, 23 HGGs) who had undergone 3.0 Tesla diffusion-weighted imaging and time required for each method of ADC measurements was recorded. Intraclass correlation coefficients (ICCs) were used to assess interobserver variability of ADC measurements. Mean and minimum ADC values and time required were compared using paired Student's t-tests. All ADC parameters (mean/minimum ADC values of three single-slice methods, mean/minimum/standard deviation/skewness/kurtosis/the10 th and 25 th percentiles/median/maximum of whole-volume method) were correlated with tumor grade (low versus high) by unpaired Student's t-tests. Discriminative ability was determined by receiver operating characteristic curves. All ADC measurements except minimum, skewness, and kurtosis of whole-volume ROI differed significantly between LGGs and HGGs (all P < 0.05). Mean ADC value of single-round ROI had the highest effect size (0.72) and the greatest areas under the curve (0.872). Three single-slice methods had good to excellent ICCs (0.67-0.89) and the whole-volume method fair to excellent ICCs (0.32-0.96). Minimum ADC values differed significantly between whole-volume and single-round ROI (P = 0.003) and, between whole-volume and five-round ROI (P = 0.001). The whole-volume method took significantly longer than all single-slice methods (all P < 0.001). ADC measurements are influenced by ROI determination methods. Whole-volume histogram analysis did not yield better results than single-slice methods and took longer. Mean ADC value derived from single-round ROI is the most optimal parameter for differentiating LGGs from HGGs. 3 J. Magn. Reson. Imaging 2017;45:722-730. © 2016 International Society for Magnetic Resonance in Medicine.

  17. A mechano-acoustic indentor system for in vivo measurement of nonlinear elastic properties of soft tissue.

    PubMed

    Koo, Terry K; Cohen, Jeffrey H; Zheng, Yongping

    2011-11-01

    Soft tissue exhibits nonlinear stress-strain behavior under compression. Characterizing its nonlinear elasticity may aid detection, diagnosis, and treatment of soft tissue abnormality. The purposes of this study were to develop a rate-controlled Mechano-Acoustic Indentor System and a corresponding finite element optimization method to extract nonlinear elastic parameters of soft tissue and evaluate its test-retest reliability. An indentor system using a linear actuator to drive a force-sensitive probe with a tip-mounted ultrasound transducer was developed. Twenty independent sites at the upper lateral quadrant of the buttock from 11 asymptomatic subjects (7 men and 4 women from a chiropractic college) were indented at 6% per second for 3 sessions, each consisting of 5 trials. Tissue thickness, force at 25% deformation, and area under the load-deformation curve from 0% to 25% deformation were calculated. Optimized hyperelastic parameters of the soft tissue were calculated with a finite element model using a first-order Ogden material model. Load-deformation response on a standardized block was then simulated, and the corresponding area and force parameters were calculated. Between-trials repeatability and test-retest reliability of each parameter were evaluated using coefficients of variation and intraclass correlation coefficients, respectively. Load-deformation responses were highly reproducible under repeated measurements. Coefficients of variation of tissue thickness, area under the load-deformation curve from 0% to 25% deformation, and force at 25% deformation averaged 0.51%, 2.31%, and 2.23%, respectively. Intraclass correlation coefficients ranged between 0.959 and 0.999, indicating excellent test-retest reliability. The automated Mechano-Acoustic Indentor System and its corresponding optimization technique offers a viable technology to make in vivo measurement of the nonlinear elastic properties of soft tissue. This technology showed excellent between-trials repeatability and test-retest reliability with potential to quantify the effects of a wide variety of manual therapy techniques on the soft tissue elastic properties. Copyright © 2011 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  18. Reliability of mercury-in-silastic strain gauge plethysmography curve reading: influence of clinical clues and observer variation.

    PubMed

    Høyer, Christian; Pavar, Susanne; Pedersen, Begitte H; Biurrun Manresa, José A; Petersen, Lars J

    2013-08-01

    Mercury-in-silastic strain gauge pletysmography (SGP) is a well-established technique for blood flow and blood pressure measurements. The aim of this study was to examine (i) the possible influence of clinical clues, e.g. the presence of wounds and color changes during blood pressure measurements, and (ii) intra- and inter-observer variation of curve interpretation for segmental blood pressure measurements. A total of 204 patients with known or suspected peripheral arterial disease (PAD) were included in a diagnostic accuracy trial. Toe and ankle pressures were measured in both limbs, and primary observers analyzed a total of 804 pressure curve sets. The SGP curves were later reanalyzed separately by two observers blinded to clinical clues. Intra- and inter-observer agreement was quantified using Cohen's kappa and reliability was quantified using intra-class correlation coefficients, coefficients of variance, and Bland-Altman analysis. There was an overall agreement regarding patient diagnostic classification (PAD/not PAD) in 202/204 (99.0%) for intra-observer (κ = 0.969, p < 0.001), and 201/204 (98.5%) for inter-observer readings (κ = 0.953, p < 0.001). Reliability analysis showed excellent correlation between blinded versus non-blinded and inter-observer readings for determination of absolute segmental pressures (all intraclass correlation coefficients ≥ 0.984). The coefficient of variance for determination of absolute segmental blood pressure ranged from 2.9-3.4% for blinded/non-blinded data and from 3.8-5.0% for inter-observer data. This study shows a low inter-observer variation among experienced laboratory technicians for reading strain gauge curves. The low variation between blinded/non-blinded readings indicates that SGP measurements are minimally biased by clinical clues.

  19. Digital Photoplethysmography for Assessment of Arterial Stiffness: Repeatability and Comparison with Applanation Tonometry

    PubMed Central

    Östling, Gerd; Nilsson, Peter M.

    2015-01-01

    Introduction Arterial stiffness is an independent risk factor for cardiovascular morbidity and can be assessed by applanation tonometry by measuring pulse wave velocity (PWV) and augmentation index (AIX) by pressure pulse wave analysis (PWA). As an inexpensive and operator independent alternative, photoelectric plethysmography (PPG) has been introduced with analysis of the digital volume pulse wave (DPA) and its second derivatives of wave reflections. Objective The objective was to investigate the repeatability of arterial stiffness parameters measured by digital pulse wave analysis (DPA) and the associations to applanation tonometry parameters. Methods and Results 112 pregnant and non-pregnant individuals of different ages and genders were examined with SphygmoCor arterial wall tonometry and Meridian DPA finger photoplethysmography. Coefficients of repeatability, Bland-Altman plots, intraclass correlation coefficients and correlations to heart rate (HR) and body height were calculated for DPA variables, and the DPA variables were compared to tonometry variables left ventricular ejection time (LVET), PWV and AIX. No DPA variable showed any systematic measurement error or excellent repeatability, but dicrotic index (DI), dicrotic dilatation index (DDI), cardiac ejection elasticity index (EEI), aging index (AI) and second derivatives of the crude pulse wave curve, b/a and e/a, showed good repeatability. Overall, the correlations to AIX were better than to PWV, with correlations coefficients >0.70 for EEI, AI and b/a. Considering the level of repeatability and the correlations to tonometry, the overall best DPA parameters were EEI, AI and b/a. The two pansystolic time parameters, ejection time compensated (ETc) by DPA and LVET by tonometry, showed a significant but weak correlation. Conclusion For estimation of the LV function, ETc, EEI and b/a are suitable, for large artery stiffness EEI, and for small arteries DI and DDI. The only global parameter, AI, showed a high repeatability and the overall best correlations with AIX and PWV. PMID:26291079

  20. Validation of an adapted arabic version of fibromyalgia syndrome impact questionnaire.

    PubMed

    El-Naby, Mai Abd; Hefny, Mohamed Ahmed; Fahim, Ayman Ekram; Awadalla, Magdy Ahmed

    2013-10-01

    Fibromyalgia (FM) is the most common chronic pain syndrome encountered in medical practice, affecting females more than males, and the estimated prevalence of FM in Egypt is 1.3 %. The aim was to translate and adapt the Fibromyalgia Impact Questionnaire (FIQ) into Arabic and assess reliability and validity. The Arabic version of Fibromyalgia Impact Questionnaire (FIQ-A) was adapted following the forward/backward translation approach. Fifty-one female patients with FM were studied to assess psychometric properties of the FIQ-A. Reliability was analyzed by the correlation coefficient between test and retest. Internal consistency was checked by the Cronbach's alpha coefficient. Construct validity was assessed comparing FIQ-A with Health Assessment Questionnaire (HAQ), Health Assessment Questionnaire of Fibromyalgia (FHAQ), The Medical Outcome Survey Short-Form-36 (SF-36), and the Total Visual Analog Scale (TVAS) for FM symptom, and feasibility was assessed by the time taken in completing the FIQ-A and the proportion of patients completed the questionnaire. Patients studied were 33.2 ± 9.8 years old. Translation was concordant. Adaptation affected 4 sub-items of physical function. Test-retest correlation coefficient was 0.89 for total FIQ-A and Cronbach's alpha was 0.76. Excellent to good statistically significant correlations (p < 0.05) were found between the FIQ-A items and HAQ, FHAQ, and SF-36. The FIQ-A is a reliable, valid for measuring health status and physical function in Arabic-speaking FM patients.

  1. A creatinine biosensor based on admittance measurement

    NASA Astrophysics Data System (ADS)

    Ching, Congo Tak-Shing; Sun, Tai-Ping; Jheng, Deng-Yun; Tsai, Hou-Wei; Shieh, Hsiu-Li

    2015-08-01

    Regular check of blood creatinine level is very important as it is a measurement of renal function. Therefore, the objective of this study is to develop a simple and reliable creatinine biosensor based on admittance measurement for precise determination of creatinine. The creatinine biosensor was fabricated with creatinine deiminase immobilized on screen-printed carbon electrodes. Admittance measurement at a specific frequency ranges (22.80 - 84.71 Hz) showed that the biosensor has an excellent linear (r2 > 0.95) response range (50 - 250 uM), which covers the normal physiological and pathological ranges of blood creatinine levels. Intraclass correlation coefficient (ICC) showed that the biosensor has excellent reliability and validity (ICC = 0.98). In conclusion, a simple and reliable creatinine biosensor was developed and it is capable of precisely determining blood creatinine levels in both the normal physiological and pathological ranges.

  2. Pulmonary disease in cystic fibrosis: assessment with chest CT at chest radiography dose levels.

    PubMed

    Ernst, Caroline W; Basten, Ines A; Ilsen, Bart; Buls, Nico; Van Gompel, Gert; De Wachter, Elke; Nieboer, Koenraad H; Verhelle, Filip; Malfroot, Anne; Coomans, Danny; De Maeseneer, Michel; de Mey, Johan

    2014-11-01

    To investigate a computed tomographic (CT) protocol with iterative reconstruction at conventional radiography dose levels for the assessment of structural lung abnormalities in patients with cystic fibrosis ( CF cystic fibrosis ). In this institutional review board-approved study, 38 patients with CF cystic fibrosis (age range, 6-58 years; 21 patients <18 years and 17 patients >18 years) underwent investigative CT (at minimal exposure settings combined with iterative reconstruction) as a replacement of yearly follow-up posteroanterior chest radiography. Verbal informed consent was obtained from all patients or their parents. CT images were randomized and rated independently by two radiologists with use of the Bhalla scoring system. In addition, mosaic perfusion was evaluated. As reference, the previous available conventional chest CT scan was used. Differences in Bhalla scores were assessed with the χ(2) test and intraclass correlation coefficients ( ICC intraclass correlation coefficient s). Radiation doses for CT and radiography were assessed for adults (>18 years) and children (<18 years) separately by using technical dose descriptors and estimated effective dose. Differences in dose were assessed with the Mann-Whitney U test. The median effective dose for the investigative protocol was 0.04 mSv (95% confidence interval [ CI confidence interval ]: 0.034 mSv, 0.10 mSv) for children and 0.05 mSv (95% CI confidence interval : 0.04 mSv, 0.08 mSv) for adults. These doses were much lower than those with conventional CT (median: 0.52 mSv [95% CI confidence interval : 0.31 mSv, 3.90 mSv] for children and 1.12 mSv [95% CI confidence interval : 0.57 mSv, 3.15 mSv] for adults) and of the same order of magnitude as those for conventional radiography (median: 0.012 mSv [95% CI confidence interval : 0.006 mSv, 0.022 mSv] for children and 0.012 mSv [95% CI confidence interval : 0.005 mSv, 0.031 mSv] for adults). All images were rated at least as diagnostically acceptable. Very good agreement was found in overall Bhalla score ( ICC intraclass correlation coefficient , 0.96) with regard to the severity of bronchiectasis ( ICC intraclass correlation coefficient , 0.87) and sacculations and abscesses ( ICC intraclass correlation coefficient , 0.84). Interobserver agreement was excellent ( ICC intraclass correlation coefficient , 0.86-1). For patients with CF cystic fibrosis , a dedicated chest CT protocol can replace the two yearly follow-up chest radiographic examinations without major dose penalty and with similar diagnostic quality compared with conventional CT.

  3. Can diffusion-weighted imaging serve as a biomarker of fibrosis in pancreatic adenocarcinoma?

    PubMed

    Hecht, Elizabeth M; Liu, Michael Z; Prince, Martin R; Jambawalikar, Sachin; Remotti, Helen E; Weisberg, Stuart W; Garmon, Donald; Lopez-Pintado, Sara; Woo, Yanghee; Kluger, Michael D; Chabot, John A

    2017-08-01

    To assess the relationship between diffusion-weighted imaging (DWI) and intravoxel incoherent motion (IVIM)-derived quantitative parameters (apparent diffusion coefficient [ADC], perfusion fraction [f], D slow , diffusion coefficient [D], and D fast , pseudodiffusion coefficient [D*]) and histopathology in pancreatic adenocarcinoma (PAC). Subjects with suspected surgically resectable PAC were prospectively enrolled in this Health Insurance Portability and Accountability Act (HIPAA)-compliant, Institutional Review Board-approved study. Imaging was performed at 1.5T with a respiratory-triggered echo planar DWI sequence using 10 b values. Two readers drew regions of interest (ROIs) over the tumor and adjacent nontumoral tissue. Monoexponential and biexponential fits were used to derive ADC 2b , ADC all , f, D, and D*, which were compared to quantitative histopathology of fibrosis, mean vascular density, and cellularity. Two biexponential IVIM models were investigated and compared: 1) nonlinear least-square fitting based on the Levenberg-Marquardt algorithm, and 2) linear fit using a fixed D* (20 mm 2 /s). Statistical analysis included Student's t-test, Pearson correlation (P < 0.05 was considered significant), intraclass correlation, and coefficients of variance. Twenty subjects with PAC were included in the final cohort. Negative correlation between D and fibrosis (Reader 2: r = -0.57 P = 0.01; pooled P = -0.46, P = 0.04) was observed with a trend toward positive correlation between f and fibrosis (r = 0.44, P = 0.05). ADC 2b was significantly lower in PAC with dense fibrosis than with loose fibrosis ADC 2b (P = 0.03). Inter- and intrareader agreement was excellent for ADC, D, and f. In PAC, D negatively correlates with fibrosis, with a trend toward positive correlation with f suggesting both perfusion and diffusion effects contribute to stromal desmoplasia. ADC 2b is significantly lower in tumors with dense fibrosis and may serve as a biomarker of fibrosis architecture. 1 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:393-402. © 2017 International Society for Magnetic Resonance in Medicine.

  4. ASSOCIATIONS BETWEEN THREE CLINICAL ASSESSMENT TOOLS FOR POSTURAL STABILITY

    PubMed Central

    Saxion, Casie E.; Cameron, Kenneth L.; Gerber, J. Parry

    2010-01-01

    Study Design: Clinical Measurement, Correlation, Reliability Objectives: To assess the relationship between the Single Leg Balance (SLB), modified Balance Error Scoring System (mBESS), and modified Star Excursion Balance (mSEBT) tests and secondarily to assess inter-rater and test-retest reliability of these tests. Background: Ankle sprains often result in chronic instability and dysfunction. Several clinical tests assess postural deficits as a potential cause of this dysfunction; however, limited information exists pertaining to the relationship that these tests have with one another. Methods: Two independent examiners measured the performance of 34 healthy participants completing the SLB Test, mBESS test, and mSEBT at two different time periods. The relationship between tests was assessed using the Pearson Correlation and Fisher's Exact Tests. Inter-rater and test-retest reliability were assessed using the intraclass correlation coefficient (ICC) and Kappa statistics. Results: A significant correlation (r = -0.35) was observed between the mSEBT and the mBESS. Fisher's Exact Test showed a significant association between the SLB Test and mBESS (P = .048), but no association between the SLB and mSEBT (P = 1.000). Inter-rater reliability was excellent for the mSEBT and fair for the mBESS (ICCs of .91 and .61 respectively). Excellent agreement was observed between raters for the SLB test (k = 1.00). Test-retest reliability was excellent for the mSEBT (ICC = 0.98) and fair for the mBESS (ICC = 0.74). There was poor test-retest agreement for the SLB test (k = .211). Conclusion: There was a significant relationship observed between the SLB Test, mBESS test, and mSEBT: however; strength of association measures showed limited overlap between these tests. This suggests that these tests are interrelated but may not assess equal components of postural stability. PMID:21589668

  5. Assessing distractors and teamwork during surgery: developing an event-based method for direct observation.

    PubMed

    Seelandt, Julia C; Tschan, Franziska; Keller, Sandra; Beldi, Guido; Jenni, Nadja; Kurmann, Anita; Candinas, Daniel; Semmer, Norbert K

    2014-11-01

    To develop a behavioural observation method to simultaneously assess distractors and communication/teamwork during surgical procedures through direct, on-site observations; to establish the reliability of the method for long (>3 h) procedures. Observational categories for an event-based coding system were developed based on expert interviews, observations and a literature review. Using Cohen's κ and the intraclass correlation coefficient, interobserver agreement was assessed for 29 procedures. Agreement was calculated for the entire surgery, and for the 1st hour. In addition, interobserver agreement was assessed between two tired observers and between a tired and a non-tired observer after 3 h of surgery. The observational system has five codes for distractors (door openings, noise distractors, technical distractors, side conversations and interruptions), eight codes for communication/teamwork (case-relevant communication, teaching, leadership, problem solving, case-irrelevant communication, laughter, tension and communication with external visitors) and five contextual codes (incision, last stitch, personnel changes in the sterile team, location changes around the table and incidents). Based on 5-min intervals, Cohen's κ was good to excellent for distractors (0.74-0.98) and for communication/teamwork (0.70-1). Based on frequency counts, intraclass correlation coefficient was excellent for distractors (0.86-0.99) and good to excellent for communication/teamwork (0.45-0.99). After 3 h of surgery, Cohen's κ was 0.78-0.93 for distractors, and 0.79-1 for communication/teamwork. The observational method developed allows a single observer to simultaneously assess distractors and communication/teamwork. Even for long procedures, high interobserver agreement can be achieved. Data collected with this method allow for investigating separate or combined effects of distractions and communication/teamwork on surgical performance and patient outcomes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Calcaneotalar ratio: a new concept in the estimation of the length of the calcaneus.

    PubMed

    David, Vikram; Stephens, Terry J; Kindl, Radek; Ang, Andy; Tay, Wei-Han; Asaid, Rafik; McCullough, Keith

    2015-01-01

    Maintaining the calcaneal length after calcaneal fractures is vital to restoring the normal biomechanics of the foot, because it acts as an important lever arm to the plantarflexors of the foot. However, estimation of the length of the calcaneus to be reconstructed in comminuted calcaneal fractures can be difficult. We propose a new method to reliably estimate the calcaneal length radiographically by defining the calcaneotalar length ratio. A total of 100 ankle radiographs with no fracture in the calcaneus or talus taken in skeletally mature patients were reviewed by 6 observers. The anteroposterior lengths of the calcaneus and talus were measured, and the calcaneotalar length ratio was determined. The ratio was then used to estimate the length of the calcaneus. Interobserver reliability was determined using Cronbach's α coefficient and Pearson's correlation coefficient. The mean length of the calcaneus was 75 ± 0.6 mm, and the mean length of the talus was 59 ± 0.5 mm. The calcaneotalar ratio was 1.3. Using this ratio and multiplying it by the talar length, the mean average estimated length of the calcaneus was within 0.7 mm of the known calcaneal length. Cronbach's α coefficient and Pearson's correlation coefficient showed excellent interobserver reliability. The proposed calcaneotalar ratio is a new and reliable method to radiographically estimate the normal length of the calcaneus when reconstructing the calcaneus. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Assessing Patients’ Experiences with Communication Across the Cancer Care Continuum

    PubMed Central

    Mazor, Kathleen M.; Street, Richard L.; Sue, Valerie M.; Williams, Andrew E.; Rabin, Borsika A.; Arora, Neeraj K.

    2016-01-01

    Objective To evaluate the relevance, performance and potential usefulness of the Patient Assessment of cancer Communication Experiences (PACE) items. Methods Items focusing on specific communication goals related to exchanging information, fostering healing relationships, responding to emotions, making decisions, enabling self-management, and managing uncertainty were tested via a retrospective, cross-sectional survey of adults who had been diagnosed with cancer. Analyses examined response frequencies, inter-item correlations, and coefficient alpha. Results A total of 366 adults were included in the analyses. Relatively few selected “Does Not Apply”, suggesting that items tap relevant communication experiences. Ratings of whether specific communication goals were achieved were strongly correlated with overall ratings of communication, suggesting item content reflects important aspects of communication. Coefficient alpha was ≥.90 for each item set, indicating excellent reliability. Variations in the percentage of respondents selecting the most positive response across items suggest results can identify strengths and weaknesses. Conclusion The PACE items tap relevant, important aspects of communication during cancer care, and may be useful to cancer care teams desiring detailed feedback. PMID:26979476

  8. Molecular Dynamics Simulation of the Cage Effect in a Wide Packing Fraction Range

    NASA Astrophysics Data System (ADS)

    Pestryaev, E. M.

    2018-07-01

    The self-diffusion coefficient and particle residence time in the first coordination shell of its neighbours were investigated by molecular dynamics simulation with the packing fraction of the model system ranging from 0.1 to 0.8. The residence time distribution spans several orders of magnitude and broadens with the system packing fraction. The distribution exhibits a maximum localized in the short residence time region. The average residence time correlates with the conventionally-used intermolecular correlation time governed by the mutual particle translational diffusion. It was shown that the use of the coordination number as an argument for all searched parameters is the obvious representation of the cage effect onset. The agreement of the self-diffusion coefficient with one of the recent theories is excellent in most of the density range, including the start of the glass transition, with the largest divergence only observed for the rare gas state. The same conclusion is true for the simulated and theoretical values of the caging number, which is nearly five, defining the start of the system liquefaction.

  9. An effective approach to quantitative analysis of ternary amino acids in foxtail millet substrate based on terahertz spectroscopy.

    PubMed

    Lu, Shao Hua; Li, Bao Qiong; Zhai, Hong Lin; Zhang, Xin; Zhang, Zhuo Yong

    2018-04-25

    Terahertz time-domain spectroscopy has been applied to many fields, however, it still encounters drawbacks in multicomponent mixtures analysis due to serious spectral overlapping. Here, an effective approach to quantitative analysis was proposed, and applied on the determination of the ternary amino acids in foxtail millet substrate. Utilizing three parameters derived from the THz-TDS, the images were constructed and the Tchebichef image moments were used to extract the information of target components. Then the quantitative models were obtained by stepwise regression. The correlation coefficients of leave-one-out cross-validation (R loo-cv 2 ) were more than 0.9595. As for external test set, the predictive correlation coefficients (R p 2 ) were more than 0.8026 and the root mean square error of prediction (RMSE p ) were less than 1.2601. Compared with the traditional methods (PLS and N-PLS methods), our approach is more accurate, robust and reliable, and can be a potential excellent approach to quantify multicomponent with THz-TDS spectroscopy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. A portable x-ray fluorescence instrument for analyzing dust wipe samples for lead: evaluation with field samples.

    PubMed

    Sterling, D A; Lewis, R D; Luke, D A; Shadel, B N

    2000-06-01

    Dust wipe samples collected in the field were tested by nondestructive X-ray fluorescence (XRF) followed by laboratory analysis with flame atomic absorption spectrophotometry (FAAS). Data were analyzed for precision and accuracy of measurement. Replicate samples with the XRF show high precision with an intraclass correlation coefficient (ICC) of 0.97 (P<0.0001) and an overall coefficient of variation of 11.6%. Paired comparison indicates no statistical difference (P=0.272) between XRF and FAAS analysis. Paired samples are highly correlated with an R(2) ranging between 0.89 for samples that contain paint chips and 0.93 for samples that do not contain paint chips. The ICC for absolute agreement between XRF and laboratory results was 0.95 (P<0.0001). The relative error over the concentration range of 25 to 14,200 microgram Pb is -12% (95% CI, -18 to -5). The XRF appears to be an excellent method for rapid on-site evaluation of dust wipes for clearance and risk assessment purposes, although there are indications of some confounding when paint chips are present. Copyright 2000 Academic Press.

  11. Plain film measurement error in acute displaced midshaft clavicle fractures

    PubMed Central

    Archer, Lori Anne; Hunt, Stephen; Squire, Daniel; Moores, Carl; Stone, Craig; O’Dea, Frank; Furey, Andrew

    2016-01-01

    Background Clavicle fractures are common and optimal treatment remains controversial. Recent literature suggests operative fixation of acute displaced mid-shaft clavicle fractures (DMCFs) shortened more than 2 cm improves outcomes. We aimed to identify correlation between plain film and computed tomography (CT) measurement of displacement and the inter- and intraobserver reliability of repeated radiographic measurements. Methods We obtained radiographs and CT scans of patients with acute DMCFs. Three orthopedic staff and 3 residents measured radiographic displacement at time zero and 2 weeks later. The CT measurements identified absolute shortening in 3 dimensions (by subtracting the length of the fractured from the intact clavicle). We then compared shortening measured on radiographs and shortening measured in 3 dimensions on CT. Interobserver and intraobserver reliability were calculated. Results We reviewed the fractures of 22 patients. Bland–Altman repeatability coefficient calculations indicated that radiograph and CT measurements of shortening could not be correlated owing to an unacceptable amount of measurement error (6 cm). Interobserver reliability for plain radiograph measurements was excellent (Cronbach α = 0.90). Likewise, intraobserver reliabilities for plain radiograph measurements as calculated with paired t tests indicated excellent correlation (p > 0.05 in all but 1 observer [p = 0.04]). Conclusion To establish shortening as an indication for DMCF fixation, reliable measurement tools are required. The low correlation between plain film and CT measurements we observed suggests further research is necessary to establish what imaging modality reliably predicts shortening. Our results indicate weak correlation between radiograph and CT measurement of acute DMCF shortening. PMID:27438054

  12. Measuring Eccentric Strength of the Shoulder External Rotators Using a Handheld Dynamometer: Reliability and Validity

    PubMed Central

    Johansson, Fredrik R.; Skillgate, Eva; Lapauw, Mattis L.; Clijmans, Dorien; Deneulin, Valentijn P.; Palmans, Tanneke; Engineer, Human Kinetic; Cools, Ann M.

    2015-01-01

    Context Shoulder strength assessment plays an important role in the clinical examination of the shoulder region. Eccentric strength measurements are of special importance in guiding the clinician in injury prevention or return-to-play decisions after injury. Objective To examine the absolute and relative reliability and validity of a standardized eccentric strength-measurement protocol for the glenohumeral external rotators. Design Descriptive laboratory study. Setting Testing environment at the Department of Rehabilitation Sciences and Physiotherapy of Ghent University, Belgium. Patients or Other Participants Twenty-five healthy participants (9 men and 16 women) without any history of shoulder pain were tested by 2 independent assessors using a handheld dynamometer (HHD) and underwent an isokinetic testing procedure. Intervention(s) The clinical protocol used an HHD, a DynaPort accelerometer to measure acceleration and angular velocity of testing 30°/s over 90° of range of motion, and a Biodex dynamometer to measure isokinetic activity. Main Outcome Measure(s) Three eccentric strength measurements: (1) tester 1 with the HHD, (2) tester 2 with the HHD, and (3) Biodex isokinetic strength measurement. Results The intratester reliability was excellent (0.879 and 0.858), whereas the intertester reliability was good, with an intraclass correlation coefficient between testers of 0.714. Pearson product moment correlation coefficients of 0.78 and 0.70 were noted between the HHD and the isokinetic data, showing good validity of this new procedure. Conclusions Standardized eccentric rotator cuff strength can be tested and measured in the clinical setting with good-to-excellent reliability and validity using an HHD. PMID:25974381

  13. Adaptation and validation of the Malayalam pediatric voice handicap index.

    PubMed

    Devadas, Usha; Dhanya, M; Gunjawate, Dhanshree

    2015-09-01

    The aim of the present study was to adapt and validate the English version of pediatric voice handicap index (pVHI) into Malayalam language. The English version of pediatric voice handicap index was translated into Malayalam language using parallel back translation. The translated version was content validated by three qualified speech language pathologists. The content familiarity was carried out by 10 parents of children with voice problems. This was distributed to 136 parents (57 parents of children with dysphonia, 79 parents of children with no voice problems). The internal consistency and test--retest reliability was determined using Cronbach's alpha and intraclass correlation coefficient. Independent sample t-test was used to assess the difference in means. Kappa coefficient was used to determine the correlation between overall severity of the problem and total pVHI. Discriminant analysis was used to identify thresholds for differentiating between normal and dysphonic participants. The results obtained revealed that the Malayalam version of pVHI has an excellent internal consistency; total (α=0.974), functional (α=0.922), physical (α=0.953), and emotional (α=0.923). There was an excellent test-retest reliability; total (r=0.937), functional (r=0.954), physical (r=0.95), and emotional (r=0.929). The prediction probability of the dysphonics is 98.2% using the discriminant score function. The translated and validated pVHI tool can be effectively used in the assessment of children with voice problems. It can provide a better insight into the parents' perception of their child's voice problems. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  14. Comparing Two Processing Pipelines to Measure Subcortical and Cortical Volumes in Patients with and without Mild Traumatic Brain Injury.

    PubMed

    Reid, Matthew W; Hannemann, Nathan P; York, Gerald E; Ritter, John L; Kini, Jonathan A; Lewis, Jeffrey D; Sherman, Paul M; Velez, Carmen S; Drennon, Ann Marie; Bolzenius, Jacob D; Tate, David F

    2017-07-01

    To compare volumetric results from NeuroQuant® and FreeSurfer in a service member setting. Since the advent of medical imaging, quantification of brain anatomy has been a major research and clinical effort. Rapid advancement of methods to automate quantification and to deploy this information into clinical practice has surfaced in recent years. NeuroQuant® is one such tool that has recently been used in clinical settings. Accurate volumetric data are useful in many clinical indications; therefore, it is important to assess the intermethod reliability and concurrent validity of similar volume quantifying tools. Volumetric data from 148 U.S. service members across three different experimental groups participating in a study of mild traumatic brain injury (mTBI) were examined. Groups included mTBI (n = 71), posttraumatic stress disorder (n = 22), or a noncranial orthopedic injury (n = 55). Correlation coefficients and nonparametric group mean comparisons were used to assess reliability and concurrent validity, respectively. Comparison of these methods across our entire sample demonstrates generally fair to excellent reliability as evidenced by large intraclass correlation coefficients (ICC = .4 to .99), but little concurrent validity as evidenced by significantly different Mann-Whitney U comparisons for 26 of 30 brain structures measured. While reliability between the two segmenting tools is fair to excellent, volumetric outcomes are statistically different between the two methods. As suggested by both developers, structure segmentation should be visually verified prior to clinical use and rigor should be used when interpreting results generated by either method. Copyright © 2017 by the American Society of Neuroimaging.

  15. Assessment of medical residents' satisfaction.

    PubMed

    González-Martínez, José Francisco; García-García, José Antonio; Del Rosario Arnaud-Viñas, María; Arámbula-Morales, Enna Gabriela; Uriega-González Plata, Silvia; Mendoza-Guerrero, José Antonio

    2011-01-01

    Modern medical education is focused on students, and it is necessary to assess its level of satisfaction. A questionnaire was validated and we then conducted a study about the educational satisfaction level of medical residents of the Hospital General of Mexico. An observational, descriptive, cross-sectional and prospective study was conducted. A questionnaire of 21 items was validated and then applied to a representative sample of medical residents. Each item was evaluated with a scale from 0 to 10 and then gathered in groups: 0-5 = poor, 6-7 = average, 8 = good, 9 = very good, and 10 = excellent. Descriptive and inferential statistics were carried out using SPSS v.17.0. The questionnaire had internal validity with Cronbach's alpha >0.91 by item. Included in the study were 355 medical residents representing 37 different specialties. The performance perception of the ìheadî professors showed a wide heterogeneity: excellent (23.7%), very good (20.6%), good (16.9%), average (23.1%), poor (15.8%). Fourth-year residents and upward valued the educational performance higher (p = 0.001) as well as medical/surgical residents (p = 0.02). Intermediate-level residents valued the professor higher (p = 0.001), similar to students who were married or living with a partner (p <0.001). Upon contrasting the evaluation of the teacher's performance with the overall course performance, a linear, direct and significant correlation was obtained with Spearman's correlation coefficient = 0.78 and regression coefficient (p <0.001). We found a wide range of heterogeneity of results. Performance of the professors was the basic component to judge the quality of the residents' courses.

  16. [Reliability of static posturography in elderly persons].

    PubMed

    Bauer, C M; Gröger, I; Rupprecht, R; Tibesku, C O; Gassmann, K G

    2010-08-01

    Static posturography is used to quantify body sway. It is used to assess the balance of elderly persons who are prone to falls. There is still no general opinion concerning the reliability of force platform measurements. The aim of this study was to test the reliability of force platform parameters when measuring elderly persons. The reliability of 11 force platform parameters was tested measuring 30 elderly persons. The following parameters were calculated: mean speed of center of pressure displacement in mm/s, length of sway in mm, sway area in mm(2), amplitudes of center of pressure movement, the axis of oscillation in degrees and the person's angles of inclination in degrees. Three measurements were taken on the same day, with a resting period of 2 min. Four different test conditions were used: normal standing and narrow stand with eyes open and eyes closed, respectively. Reliability was determined by using intraclass correlation coefficients. Six parameters had excellent reliability with a correlation coefficient of >0.9: mean speed of center of pressure movement during narrow stand, area of sway during narrow stand, length of sway during normal and narrow stand, and the angle of inclination in the sagittal plane during normal stand and narrow stand. The condition "narrow stand eyes closed" proved to be the most reliable test position. Six parameters proved to have excellent reliability and are recommended to be used in further investigations. Narrow stand with eyes closed should be used as the test position. The tested protocol proved to be reliable. Whether these parameters can be used to predict falls in elderly persons remains to be investigated.

  17. 3.0 Tesla breast magnetic resonance imaging in patients with nipple discharge when mammography and ultrasound fail.

    PubMed

    Lubina, Nóra; Schedelbeck, Ulla; Roth, Anne; Weng, Andreas Max; Geissinger, Eva; Hönig, Arnd; Hahn, Dietbert; Bley, Thorsten Alexander

    2015-05-01

    To compare 3.0 Tesla breast magnetic resonance imaging (MRI) with galactography for detection of benign and malignant causes of nipple discharge in patients with negative mammography and ultrasound. We prospectively evaluated 56 breasts of 50 consecutive patients with nipple discharge who had inconspicuous mammography and ultrasound, using 3.0 Tesla breast MRI with a dedicated 16-channel breast coil, and then compared the results with galactography. Histopathological diagnoses and follow-ups were used as reference standard. Lesion size estimated on MRI was compared with the size at histopathology. Sensitivity and specificity of MRI vs. galactography for detecting pathologic findings were 95.7 % vs. 85.7 % and 69.7 % vs. 33.3 %, respectively. For the supposed concrete pathology based on MRI findings, the specificity was 67.6 % and the sensitivity 77.3 % (PPV 60.7 %, NPV 82.1 %). Eight malignant lesions were detected (14.8 %). The estimated size at breast MRI showed excellent correlation with the size at histopathology (Pearson's correlation coefficient 0.95, p < 0.0001). MRI of the breast at 3.0 Tesla is an accurate imaging test and can replace galactography in the workup of nipple discharge in patients with inconspicuous mammography and ultrasound. • Breast MRI is an excellent diagnostic tool for patients with nipple discharge. • MRI of the breast reveals malignant lesions despite inconspicuous mammography and ultrasound. • MRI of the breast has greater sensitivity and specificity than galactography. • Excellent correlation of lesion size measured at MRI and histopathology was found.

  18. The usability of a WeChat-based electronic questionnaire for collecting participant-reported data in female pelvic floor disorders: a comparison with the traditional paper-administered format.

    PubMed

    Sun, Zhi-Jing; Zhu, Lan; Liang, Maolian; Xu, Tao; Lang, Jing-He

    2016-08-01

    WeChat is a promising tool for capturing electronic data; however, no research has examined its use. This study evaluates the reliability and feasibility of WeChat for administering the Pelvic Floor Impact Questionnaire Short Form 7 questionnaire to women with pelvic floor disorders. Sixty-eight pelvic floor rehabilitation women were recruited between June and December 2015 and crossover randomized to two groups. All participants completed two questionnaire formats. One group completed the paper version followed by the WeChat version; the other group completed the questionnaires in reverse order. Two weeks later, each group completed the two versions in reverse order. The WeChat version's reliability was assessed using intraclass correlation coefficients and test-retest reliability. Forty-two women (61.8%) preferred the WeChat to the paper format, eight (11.8%) preferred the paper format, and 18 (26.5%) had no preference. The younger women preferred WeChat. Completion time was 116.5 (61.3) seconds for the WeChat version and 133.4 (107.0) seconds for the paper version, with no significant difference (P = 0.145). Age and education did not impact completion time (P > 0.05). Consistency between the WeChat and paper versions was excellent. The intraclass correlation coefficients of the Pelvic Floor Impact Questionnaire Short Form 7 and the three subscales ranged from 0.915 to 0.980. The Bland-Altman analysis and linear regression results also showed high consistency. The test-retest study had a Pearson's correlation coefficient of 0.908, demonstrating a strong correlation. WeChat-based questionnaires were well accepted by women with pelvic floor disorders and had good data quality and reliability.

  19. Five times sit-to-stand test in subjects with total knee replacement: Reliability and relationship with functional mobility tests.

    PubMed

    Medina-Mirapeix, Francesc; Vivo-Fernández, Iván; López-Cañizares, Juan; García-Vidal, José A; Benítez-Martínez, Josep Carles; Del Baño-Aledo, María Elena

    2018-01-01

    The objective was to determine the inter-observer and test/retest reliability of the "Five-repetition sit-to-stand" (5STS) test in patients with total knee replacement (TKR). To explore correlation between 5STS and two mobility tests. A reliability study was conducted among 24 (mean age 72.13, S.D. 10.67; 50% were women) outpatients with TKR. They were recruited from a traumatology unit of a public hospital via convenience sampling. A physiotherapist and trauma physician assessed each patient at the same time. The same physiotherapist realized a 5STS second measurement 45-60min after the first one. Reliability was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plots. Pearson coefficient was calculated to assess the correlation between 5STS, time up to go test (TUG) and four meters gait speed (4MGS). ICC for inter-observer and test-retest reliability of the 5STS were 0.998 (95% confidence interval [CI], 0.995-0.999) and 0.982 (95% CI, 0.959-0.992). Bland-Altman plot inter-observer showed limits between -0.82 and 1.06 with a mean of 0.11 and no heteroscedasticity within the data. Bland-Altman plot for test-retest showed the limits between 1.76 and 4.16, a mean of 1.20 and heteroscedasticity within the data. Pearson correlation coefficient revealed significant correlation between 5STS and TUG (r=0.7, p<0.001) and 4MGS (r=-0.583, p=0.003). This study demonstrates excellent inter-observer and test-retest reliability when it is used in people with TKR, and also significant correlation with other functional mobility tests. These findings support the use of 5STS as outcome measure in TKR population. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Evaluating trauma team performance in a Level I trauma center: Validation of the trauma team communication assessment (TTCA-24).

    PubMed

    DeMoor, Stephanie; Abdel-Rehim, Shady; Olmsted, Richard; Myers, John G; Parker-Raley, Jessica

    2017-07-01

    Nontechnical skills (NTS), such as team communication, are well-recognized determinants of trauma team performance and good patient care. Measuring these competencies during trauma resuscitations is essential, yet few valid and reliable tools are available. We aimed to demonstrate that the Trauma Team Communication Assessment (TTCA-24) is a valid and reliable instrument that measures communication effectiveness during activations. Two tools with adequate psychometric strength (Trauma Nontechnical Skills Scale [T-NOTECHS], Team Emergency Assessment Measure [TEAM]) were identified during a systematic review of medical literature and compared with TTCA-24. Three coders used each tool to evaluate 35 stable and 35 unstable patient activations (defined according to Advanced Trauma Life Support criteria). Interrater reliability was calculated between coders using the intraclass correlation coefficient. Spearman rank correlation coefficient was used to establish concurrent validity between TTCA-24 and the other two validated tools. Coders achieved an intraclass correlation coefficient of 0.87 for stable patient activations and 0.78 for unstable activations scoring excellent on the interrater agreement guidelines. The median score for each assessment showed good team communication for all 70 videos (TEAM, 39.8 of 54; T-NOTECHS, 17.4 of 25; and TTCA-24, 87.4 of 96). A significant correlation between TTTC-24 and T-NOTECHS was revealed (p = 0.029), but no significant correlation between TTCA-24 and TEAM (p = 0.77). Team communication was rated slightly better across all assessments for stable versus unstable patient activations, but not statistically significant. TTCA-24 correlated with T-NOTECHS, an instrument measuring nontechnical skills for trauma teams, but not TEAM, a tool that assesses communication in generic emergency settings. TTCA-24 is a reliable and valid assessment that can be a useful adjunct when evaluating interpersonal and team communication during trauma activations. Diagnostic tests or criteria, level II.

  1. Lumbar lordosis and sacral slope in lumbar spinal stenosis: standard values and measurement accuracy.

    PubMed

    Bredow, J; Oppermann, J; Scheyerer, M J; Gundlfinger, K; Neiss, W F; Budde, S; Floerkemeier, T; Eysel, P; Beyer, F

    2015-05-01

    Radiological study. To asses standard values, intra- and interobserver reliability and reproducibility of sacral slope (SS) and lumbar lordosis (LL) and the correlation of these parameters in patients with lumbar spinal stenosis (LSS). Anteroposterior and lateral X-rays of the lumbar spine of 102 patients with LSS were included in this retrospective, radiologic study. Measurements of SS and LL were carried out by five examiners. Intraobserver correlation and correlation between LL and SS were calculated with Pearson's r linear correlation coefficient and intraclass correlation coefficients (ICC) were calculated for inter- and intraobserver reliability. In addition, patients were examined in subgroups with respect to previous surgery and the current therapy. Lumbar lordosis averaged 45.6° (range 2.5°-74.9°; SD 14.2°), intraobserver correlation was between Pearson r = 0.93 and 0.98. The measurement of SS averaged 35.3° (range 13.8°-66.9°; SD 9.6°), intraobserver correlation was between Pearson r = 0.89 and 0.96. Intraobserver reliability ranged from 0.966 to 0.992 ICC in LL measurements and 0.944-0.983 ICC in SS measurements. There was an interobserver reliability ICC of 0.944 in LL and 0.990 in SS. Correlation between LL and SS averaged r = 0.79. No statistically significant differences were observed between the analyzed subgroups. Manual measurement of LL and SS in patients with LSS on lateral radiographs is easily performed with excellent intra- and interobserver reliability. Correlation between LL and SS is very high. Differences between patients with and without previous decompression were not statistically significant.

  2. Using an Extended Kalman Filter Learning Algorithm for Feed-Forward Neural Networks to Describe Tracer Correlations

    NASA Technical Reports Server (NTRS)

    Lary, David J.; Mussa, Yussuf

    2004-01-01

    In this study a new extended Kalman filter (EKF) learning algorithm for feed-forward neural networks (FFN) is used. With the EKF approach, the training of the FFN can be seen as state estimation for a non-linear stationary process. The EKF method gives excellent convergence performances provided that there is enough computer core memory and that the machine precision is high. Neural networks are ideally suited to describe the spatial and temporal dependence of tracer-tracer correlations. The neural network performs well even in regions where the correlations are less compact and normally a family of correlation curves would be required. For example, the CH4-N2O correlation can be well described using a neural network trained with the latitude, pressure, time of year, and CH4 volume mixing ratio (v.m.r.). The neural network was able to reproduce the CH4-N2O correlation with a correlation coefficient between simulated and training values of 0.9997. The neural network Fortran code used is available for download.

  3. High resolution ultrasound and magnetic resonance imaging of the optic nerve and the optic nerve sheath: anatomic correlation and clinical importance.

    PubMed

    Steinborn, M; Fiegler, J; Kraus, V; Denne, C; Hapfelmeier, A; Wurzinger, L; Hahn, H

    2011-12-01

    We performed a cadaver study to evaluate the accuracy of measurements of the optic nerve and the optic nerve sheath for high resolution US (HRUS) and magnetic resonance imaging (MRI). Five Thiel-fixated cadaver specimens of the optic nerve were examined with HRUS and MRI. Measurements of the optic nerve and the ONSD were performed before and after the filling of the optic nerve sheath with saline solution. Statistical analysis included the calculation of the agreement of measurements and the evaluation of the intraobserver and interobserver variation. Overall a good correlation of measurement values between HRUS and MRI can be found (mean difference: 0.02-0.97 mm). The repeatability coefficient (RC) and concordance correlation coefficient (CCC) values were good to excellent for most acquisitions (RC 0.2-1.11 mm; CCC 0.684-0.949). The highest variation of measurement values was found for transbulbar sonography (RC 0.58-1.83 mm; CCC 0.615/0.608). If decisive anatomic structures are clearly depicted and the measuring points are set correctly, there is a good correlation between HRUS and MRI measurements of the optic nerve and the ONSD even on transbulbar sonography. As most of the standard and cut-off values that have been published for ultrasound are significantly lower than the results obtained with MRI, a reevaluation of sonographic ONSD measurement with correlation to MRI is necessary. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Tmax Determined Using a Bayesian Estimation Deconvolution Algorithm Applied to Bolus Tracking Perfusion Imaging: A Digital Phantom Validation Study.

    PubMed

    Uwano, Ikuko; Sasaki, Makoto; Kudo, Kohsuke; Boutelier, Timothé; Kameda, Hiroyuki; Mori, Futoshi; Yamashita, Fumio

    2017-01-10

    The Bayesian estimation algorithm improves the precision of bolus tracking perfusion imaging. However, this algorithm cannot directly calculate Tmax, the time scale widely used to identify ischemic penumbra, because Tmax is a non-physiological, artificial index that reflects the tracer arrival delay (TD) and other parameters. We calculated Tmax from the TD and mean transit time (MTT) obtained by the Bayesian algorithm and determined its accuracy in comparison with Tmax obtained by singular value decomposition (SVD) algorithms. The TD and MTT maps were generated by the Bayesian algorithm applied to digital phantoms with time-concentration curves that reflected a range of values for various perfusion metrics using a global arterial input function. Tmax was calculated from the TD and MTT using constants obtained by a linear least-squares fit to Tmax obtained from the two SVD algorithms that showed the best benchmarks in a previous study. Correlations between the Tmax values obtained by the Bayesian and SVD methods were examined. The Bayesian algorithm yielded accurate TD and MTT values relative to the true values of the digital phantom. Tmax calculated from the TD and MTT values with the least-squares fit constants showed excellent correlation (Pearson's correlation coefficient = 0.99) and agreement (intraclass correlation coefficient = 0.99) with Tmax obtained from SVD algorithms. Quantitative analyses of Tmax values calculated from Bayesian-estimation algorithm-derived TD and MTT from a digital phantom correlated and agreed well with Tmax values determined using SVD algorithms.

  5. Reliability and validity of a Turkish version of the Global Pelvic Floor Bother Questionnaire.

    PubMed

    Doğan, Hanife; Özengin, Nuriye; Bakar, Yeşim; Duran, Bülent

    2016-10-01

    The aim of this study was to translate the Global Pelvic Floor Bother Questionnaire (GPFBQ) into Turkish and to assess its validity and reliability. The Turkish adaptation of the GPFBQ was created by following the stages of the intercultural adaptation process. A test-retest interval of 1 week was used to assess the reliability, which was examined by the intraclass correlation coefficient. The validity of the GPFBQ was assessed and compared with the Pelvic Floor Distress Inventory-20 (PFDI-20) and the Pelvic Floor Impact Questionnaire-7 (PFIQ-7) using Spearman's rank correlation coefficients. For construct validity, confirmatory factor analysis was performed. A total of 131 women, whose mean age was 46.83 years, were included in the study. The test-retest reliability of the GPFBQ was excellent (0.998, p < 0.0001). The GPFBQ correlated significantly with the PFDI-20 (r = 0.860, p = 0.00) and PFIQ-7 (r = 0.802, p = 0.00). Confirmatory factor analysis was performed to determine construct validity, and it was found that it had four dimensions. The Turkish version of the GPFBQ is a valid and reliable tool for assessing the symptoms of bother and severity in Turkish-speaking women with pelvic floor dysfunction.

  6. A paired comparison between human skin and hairless guinea pig skin in vitro permeability and lag time measurements for 6 industrial chemicals.

    PubMed

    Frasch, H Frederick; Barbero, Ana M

    2009-01-01

    The purpose of the present study was to measure and compare permeability coefficients (k(p)) and lag times (tau) in human skin and hairless guinea pig (HGP) skin. Paired experiments employed heat-separated epidermal membranes from human and HGP sources mounted on static in vitro diffusion cells. Infinite-dose, saturated aqueous solutions of 6 industrial chemicals were used as donors: aniline, benzene, 1,2- dichloroethane, diethyl phthalate, naphthalene, and tetrachloroethylene. No significant differences were found between human and HGP skin for either k(p) or tau for any of these chemicals (p >or= .24). HGP vs. human k(p) measurements, and HGP vs. human tau measurements, were highly correlated. For k(p), the slope of the linear correlation was close to unity (1.080 +/- 0.182) and the intercept close to 0 (0.015 +/- 0. 029 cm/h), with a correlation coefficient (r(2)) = 0.898. For tau, the slope was also close to unity (0.818 +/- 0.030) and the intercept close to 0 (-0.014 +/- 0.023 h), with r(2) = 0.994. These results suggest that HGP skin may serve as an excellent surrogate for human skin in in vitro dermal penetration studies.

  7. Optical coherence tomography in retinitis pigmentosa: reproducibility and capacity to detect macular and retinal nerve fiber layer thickness alterations.

    PubMed

    Garcia-Martin, Elena; Pinilla, Isabel; Sancho, Eva; Almarcegui, Carmen; Dolz, Isabel; Rodriguez-Mena, Diego; Fuertes, Isabel; Cuenca, Nicolas

    2012-09-01

    To evaluate the ability of time-domain and Fourier-domain optical coherence tomographies (OCTs) to detect macular and retinal nerve fiber layer atrophies in retinitis pigmentosa (RP). To test the intrasession reproducibility using three OCT instruments (Stratus, Cirrus, and Spectralis). Eighty eyes of 80 subjects (40 RP patients and 40 healthy subjects) underwent a visual field examination, together with 3 macular scans and 3 optic disk evaluations by the same experienced examiner using 3 OCT instruments. Differences between healthy and RP eyes were compared. The relationship between measurements with each OCT instrument was evaluated. Repeatability was studied by intraclass correlation coefficients and coefficients of variation. Macular and retinal nerve fiber layer atrophies were detected in RP patients for all OCT parameters. Macular and retinal nerve fiber layer thicknesses, as determined by the different OCTs, were correlated but significantly different (P < 0.05). Reproducibility was moderately high using Stratus, good using Cirrus and Spectralis, and excellent using the Tru-track technology of Spectralis. In RP eyes, measurements showed higher variability compared with healthy eyes. Differences in thickness measurements existed between OCT instruments, despite there being a high degree of correlation. Fourier-domain OCT can be considered a valid and repeatability technique to detect retinal nerve fiber layer atrophy in RP patients.

  8. Performance evaluation of BC-3200 hematology analyzer in a university hospital.

    PubMed

    Peng, L; Bai, L; Nie, L; Wu, Z; Yan, C

    2008-06-01

    The BC-3200 automated hematology analyzer was evaluated and compared with the Beckman-Coulter AcT (Ac.T diff 2) 3-part differential hematology analyzer. The BC-3200 was evaluated according to guidelines published by the International Committee for Standardization in Hematology (ICSH), Clinical and Laboratory Standards Institute (CLSI), and Department of Food and Drug Administration (FDA). The results demonstrated no background, minimal carryover (<0.5%), and excellent linearity for hemoglobin (Hb) level, white blood cell (WBC), red blood cell (RBC), and platelet (PLT) counts (>0.998). Precision was generally acceptable for all complete blood count (CBC) parameters; coefficients of variation (CVs) were within the manufacturer's claims and CVs of CBC parameters, including WBC, RBC and PLT counts, Hb and mean corpuscular volume, were <6%. Correlation between the BC-3200 and Ac.T diff 2 was excellent (r > 0.98) for all major CBC parameters (WBC, RBC, and PLT counts and Hb). We conclude that the overall performance of the BC-3200 is excellent and compares well with that of the Coulter Ac.T diff 2.

  9. Inter-arch digital model vs. manual cast measurements: Accuracy and reliability.

    PubMed

    Kiviahde, Heikki; Bukovac, Lea; Jussila, Päivi; Pesonen, Paula; Sipilä, Kirsi; Raustia, Aune; Pirttiniemi, Pertti

    2017-06-28

    The purpose of this study was to evaluate the accuracy and reliability of inter-arch measurements using digital dental models and conventional dental casts. Thirty sets of dental casts with permanent dentition were examined. Manual measurements were done with a digital caliper directly on the dental casts, and digital measurements were made on 3D models by two independent examiners. Intra-class correlation coefficients (ICC), a paired sample t-test or Wilcoxon signed-rank test, and Bland-Altman plots were used to evaluate intra- and inter-examiner error and to determine the accuracy and reliability of the measurements. The ICC values were generally good for manual and excellent for digital measurements. The Bland-Altman plots of all the measurements showed good agreement between the manual and digital methods and excellent inter-examiner agreement using the digital method. Inter-arch occlusal measurements on digital models are accurate and reliable and are superior to manual measurements.

  10. The Children's Play Therapy Instrument (CPTI): Description, Development, and Reliability Studies

    PubMed Central

    Kernberg, Paulina F.; Chazan, Saralea E.; Normandin, Lina

    1998-01-01

    The Children's Play Therapy Instrument (CPTI), its development, and reliability studies are described. The CPTI is a new instrument to examine a child's play activity in individual psychotherapy. Three independent raters used the CPTI to rate eight videotaped play therapy vignettes. Results were compared with the authors' consensual scores from a preliminary study. Generally good to excellent levels of interrater reliability were obtained for the independent raters on intraclass correlation coefficients for ordinal categories of the CPTI. Likewise, kappa levels were acceptable to excellent for nominal categories of the scale. The CPTI holds promise to become a reliable measure of play activity in child psychotherapy. Further research is needed to assess discriminant validity of the CPTI for use as a diagnostic tool and as a measure of process and outcome.(The Journal of Psychotherapy Practice and Research 1998; 7:196–207) PMID:9631341

  11. Sciatic neurosteatosis: Relationship with age, gender, obesity and height.

    PubMed

    Ratner, Shayna; Khwaja, Raamis; Zhang, Lihua; Xi, Yin; Dessouky, Riham; Rubin, Craig; Chhabra, Avneesh

    2018-04-01

    To evaluate inter-reader performance for cross-sectional area and fat quantification of bilateral sciatic nerves on MRI and assess correlations with anthropometrics. In this IRB-approved, HIPPA-compliant study, three readers performed a cross-sectional analysis of 3T lumbosacral plexus MRIs over an 18-month period. Image slices were evaluated at two levels (A and B). The sciatic nerve was outlined using a free hand region of interest tool on PACS. Proton-density fat fraction (FF) and cross-sectional areas were recorded. Inter-reader agreement was assessed using intra-class correlation coefficient (ICC). Spearman correlation coefficients were used for correlations with age, BMI and height and Wilcoxon rank sum test was used to assess gender differences. A total of 67 patients were included in this study with male to female ratio of 1:1. Inter-reader agreement was good to excellent for FF measurements at both levels (ICC=0.71-0.90) and poor for sciatic nerve areas (ICC=0.08-0.27). Positive correlations of sciatic FF and area were seen with age (p value<0.05). Males had significantly higher sciatic intraneural fat than females (p<0.05). Fat quantification MRI is highly reproducible with significant positive correlations of sciatic FF and area with age, which may have implications for MRI diagnosis of sciatic neuropathy. • MR proton density fat fraction is highly reproducible at multiple levels. • Sciatic intraneural fat is positively correlated with increasing age (p < 0.05). • Positive correlations exist between bilateral sciatic nerve areas and age (p < 0.05). • Males had significantly higher sciatic intraneural fat than females (p < 0.05).

  12. Prospective Study Validating Inter- and Intraobserver Variability of Tissue Compliance Meter in Breast Tissue of Healthy Volunteers: Potential Implications for Patients With Radiation-Induced Fibrosis of the Breast

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wernicke, A. Gabriella, E-mail: gaw9008@med.cornell.ed; Parashar, Bhupesh; Kulidzhanov, Fridon

    2011-05-01

    Purpose: Accurate detection of radiation-induced fibrosis (RIF) is crucial in management of breast cancer survivors. Tissue compliance meter (TCM) has been validated in musculature. We validate TCM in healthy breast tissue with respect to interobserver and intraobserver variability before applying it in RIF. Methods and Materials: Three medical professionals obtained three consecutive TCM measurements in each of the four quadrants of the right and left breasts of 40 women with no breast disease or surgical intervention. The intraclass correlation coefficient (ICC) assessed interobserver variability. The paired t test and Pearson correlation coefficient (r) were used to assess intraobserver variability withinmore » each rater. Results: The median age was 45 years (range, 24-68 years). The median bra size was 35C (range, 32A-40DD). Of the participants, 27 were white (67%), 4 black (10%), 5 Asian (13%), and 4 Hispanic (10%). ICCs indicated excellent interrater reliability (low interobserver variability) among the three raters, by breast and quadrant (all ICC {>=}0.99). The paired t test and Pearson correlation coefficient both indicated low intraobserver variability within each rater (right vs. left breast), stratified by quadrant (all r{>=} 0.94, p < 0.0001). Conclusions: The interobserver and intraobserver variability is small using TCM in healthy mammary tissue. We are now embarking on a prospective study using TCM in women with breast cancer at risk of developing RIF that may guide early detection, timely therapeutic intervention, and assessment of success of therapy for RIF.« less

  13. QSPR study of polychlorinated diphenyl ethers by molecular electronegativity distance vector (MEDV-4).

    PubMed

    Sun, Lili; Zhou, Liping; Yu, Yu; Lan, Yukun; Li, Zhiliang

    2007-01-01

    Polychlorinated diphenyl ethers (PCDEs) have received more and more concerns as a group of ubiquitous potential persistent organic pollutants (POPs). By using molecular electronegativity distance vector (MEDV-4), multiple linear regression (MLR) models are developed for sub-cooled liquid vapor pressures (P(L)), n-octanol/water partition coefficients (K(OW)) and sub-cooled liquid water solubilities (S(W,L)) of 209 PCDEs and diphenyl ether. The correlation coefficients (R) and the leave-one-out cross-validation (LOO) correlation coefficients (R(CV)) of all the 6-descriptor models for logP(L), logK(OW) and logS(W,L) are more than 0.98. By using stepwise multiple regression (SMR), the descriptors are selected and the resulting models are 5-descriptor model for logP(L), 4-descriptor model for logK(OW), and 6-descriptor model for logS(W,L), respectively. All these models exhibit excellent estimate capabilities for internal sample set and good predictive capabilities for external samples set. The consistency between observed and estimated/predicted values for logP(L) is the best (R=0.996, R(CV)=0.996), followed by logK(OW) (R=0.992, R(CV)=0.992) and logS(W,L) (R=0.983, R(CV)=0.980). By using MEDV-4 descriptors, the QSPR models can be used for prediction and the model predictions can hence extend the current database of experimental values.

  14. Estimation of Koc values for deuterated benzene, toluene, and ethylbenzene, and application to ground water contamination studies.

    PubMed

    Poulson, S R; Drever, J I; Colberg, P J

    1997-11-01

    Sorption partition coefficients between water and organic carbon (Koc) for deuterated benzene, toluene, and ethylbenzene have been estimated by measuring values of the octanol-water partition coefficient (Kow) and HPLC retention factors (k1), which correlate closely to values of Koc. Measured values of log Kow for non-deuterated and deuterated toluene are 2.77 (+/- 0.02) and 2.78 (+/- 0.04), respectively, indicating that within experimental error, log Koc for deuterated and non-deuterated toluene are the same. The HPLC method provides greater precision, and yields values of delta log Koc (= log Koc [deuterated]-log Koc [non-deuterated]) of -0.021 (+/- 0.001) for benzene, -0.028 (+/- 0.002) for toluene, and -0.035 (+/- 0.003) for ethylbenzene. The small values of delta log Koc demonstrates that deuterated compounds are excellent tracers for the hydrologic behavior of ground water contaminants.

  15. [Design and validation of a satisfaction survey with pharmaceutical care received in hospital pharmacyconsultation].

    PubMed

    Monje-Agudo, Patricia; Borrego-Izquierdo, Yolanda; Robustillo-Cortés, Ma de Las Aguas; Jiménez-Galán, Rocio; Almeida-González, Carmen V; Morillo-Verdugo, Ramón A

    2015-05-01

    To design and to validate a questionnaire to assess satisfaction with pharmaceutical care (PC) received at the hospital pharmacy. Multicentric study in five andalusian hospital in January 2013. A bibliography search was performed in PUBMED; MESH term; pharmaceutical services, patients satisfaction and questionnaire. Next, the questionnaire was produced by Delphi methodology with ten items and with the following variables; demographics, socials, pharrmacologicals and clinics which the patient was asked for the consequences of the PC in his treatment and illness and for the acceptance with the received service. The patient could answer between one= very insufficient and five= excellent. Before the validation phase questionnaire, a pilot phase was carried out. Descriptive analysis, Cronbach's alpha coefficient and intraclass correlation coefficient (ICC) were performed in both phases. Data analysis was conducted using the SPSS statistical software package release 20.0. In the pilot phase were included 21 questionnaires and 154 of them in validation phase (response index of 100%). In the last phase, 62% (N=96) of patients were men. More than 50% of patients answered "excelent" in all items of questionnaire in both phases. The Cronbach's alpha coefficient and ICC were 0.921 and 0.915 (95%IC: 0.847-0.961) and 0.916 and 0,910 (95%IC: 0.886-0.931) in pilot and validation phases, respectively. A high reliability instrument was designed and validated to evaluate the patient satisfaction with PC received at hospital pharmacy. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  16. Adaptation and Validation of the Kannada Version of the Singing Voice Handicap Index.

    PubMed

    Gunjawate, Dhanshree R; Aithal, Venkataraja U; Guddattu, Vasudeva; Bellur, Rajashekhar

    2017-07-01

    The present study aimed to adapt and validate the Singing Voice Handicap Index (SVHI) into Kannada language using standard procedures. This is a cross-sectional study. The original English version of SVHI was translated into Kannada. It was administered on 106 Indian classical singers, of whom 22 complained of voice problems. Its internal consistency was determined using Cronbach's alpha coefficient (α), test-retest reliability using Pearson's product moment correlation and paired t test, and the difference in mean scores by independent sample t test. The results revealed that the Kannada SVHI exhibited an excellent internal consistency (α = 0.96) with a high item-to-total correlation. Further, excellent test-retest reliability (r = 0.99) and significant differences in SVHI scores were also obtained by singers with and without a voice problem (t = 12.93, df = 104, P = 0.005). The Kannada SVHI is a valid and reliable tool for self-reported assessment of singers with voice problems. It will provide a valuable insight into the singing-related voice problems as perceived by the singers themselves. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  17. Assessment of lumbosacral kyphosis in spondylolisthesis: a computer-assisted reliability study of six measurement techniques

    PubMed Central

    Glavas, Panagiotis; Mac-Thiong, Jean-Marc; Parent, Stefan; de Guise, Jacques A.

    2008-01-01

    Although recognized as an important aspect in the management of spondylolisthesis, there is no consensus on the most reliable and optimal measure of lumbosacral kyphosis (LSK). Using a custom computer software, four raters evaluated 60 standing lateral radiographs of the lumbosacral spine during two sessions at a 1-week interval. The sample size consisted of 20 normal, 20 low and 20 high grade spondylolisthetic subjects. Six parameters were included for analysis: Boxall’s slip angle, Dubousset’s lumbosacral angle (LSA), the Spinal Deformity Study Group’s (SDSG) LSA, dysplastic SDSG LSA, sagittal rotation (SR), kyphotic Cobb angle (k-Cobb). Intra- and inter-rater reliability for all parameters was assessed using intra-class correlation coefficients (ICC). Correlations between parameters and slip percentage were evaluated with Pearson coefficients. The intra-rater ICC’s for all the parameters ranged between 0.81 and 0.97 and the inter-rater ICC’s were between 0.74 and 0.98. All parameters except sagittal rotation showed a medium to large correlation with slip percentage. Dubousset’s LSA and the k-Cobb showed the largest correlations (r = −0.78 and r = −0.50, respectively). SR was associated with the weakest correlation (r = −0.10). All other parameters had medium correlations with percent slip (r = 0.31–0.43). All measurement techniques provided excellent inter- and intra-rater reliability. Dubousset’s LSA showed the strongest correlation with slip grade. This parameter can be used in the clinical setting with PACS software capabilities to assess LSK. A computer-assisted technique is recommended in order to increase the reliability of the measurement of LSK in spondylolisthesis. PMID:19015898

  18. PubMed

    Brosseau, Lucie; Laroche, Chantal; Guitard, Paulette; King, Judy; Poitras, Stéphane; Casimiro, Lynn; Barette, Julie Alexandra; Cardinal, Dominique; Cavallo, Sabrina; Laferrière, Lucie; Martini, Rose; Champoux, Nicholas; Taverne, Jennifer; Paquette, Chanyque; Tremblay, Sébastien; Sutton, Ann; Galipeau, Roseline; Tourigny, Jocelyne; Toupin-April, Karine; Loew, Laurianne; Demers, Catrine; Sauvé-Schenk, Katrine; Paquet, Nicole; Savard, Jacinthe; Lagacé, Josée; Pharand, Denyse; Vaillancourt, Véronique

    2017-01-01

    Objectives: The primary objective was to produce a French-Canadian translation of AMSTAR (a measurement tool to assess systematic reviews) and to examine the validity of the translation's contents. The secondary and tertiary objectives were to assess the inter-rater reliability and factorial construct validity of this French-Canadian version of AMSTAR. Methods: A modified approach to Vallerand's methodology (1989) for cross-cultural validation was used. 1 First, a parallel back-translation of AMSTAR 2 was performed, by both professionals and future professionals. Next, a first committee of experts (P1) examined the translations to create a first draft of the French-Canadian version of the AMSTAR tool. This draft was then evaluated and modified by a second committee of experts (P2). Following that, 18 future professionals (master's students in physiotherapy) rated this second draft of the instrument for clarity using a seven-point scale (1: very clear; 7: very ambiguous). Lastly, the principal co-investigators then reviewed the problematic elements and proposed final changes. Four independent raters used this French-Canadian version of AMSTAR to assess 20 systematic reviews that were published in French after the year 2000. An intraclass correlation coefficient (ICC) and kappa coefficient were calculated to measure the tool's inter-rater reliability. A Cronbach's alpha coefficient was also calculated to measure internal consistency. In addition, factor analysis was used to evaluate construct validity in order to determine the number of dimensions. Results: The statements on the final version of the AMSTAR tool received an average ambiguity rating of between 1.0 and 1.4. No statement received an average rating below 1.4, which indicates a high level of clarity. Inter-rater reliability ( n =4) for the instrument's total score was moderate, with an intraclass correlation coefficient of 0.61 (95% confidence interval [CI]: 0.29, 0.97). Inter-rater reliability for 82% of the individual items was good, according to the kappa values obtained. Internal consistency was excellent, with a Cronbach's alpha coefficient of 0.91 (95% CI: 0.83, 0.99). The French-Canadian version of AMSTAR is a unidimensional tool, as confirmed by factor analysis and community values greater than 0.30. Conclusion: A valid French-Canadian version of AMSTAR was created using this rigorous five-step process. This version is unidimensional, with moderate inter-rater reliability for the elements overall, and with excellent internal consistency. This tool could be valuable to French-Canadian professionals and researchers, and could also be of interest to the international Francophone community.

  19. Validation of the Chinese version of the FOUR score in the assessment of neurosurgical patients with different level of consciousness.

    PubMed

    Peng, Juan; Deng, Yingying; Chen, Fangyao; Zhang, Xiaomei; Wang, Xiaoyan; Zhou, Ying; Zhou, Hongzhen; Qiu, Binghui

    2015-12-10

    The Glasgow Coma Scale (GCS) is currently the most widely used scoring system for comatose patients. A decade ago, the Full Outline of Unresponsiveness (FOUR) score was devised to better capture four functional aspects of consciousness (eye, motor responses, brainstem reflexes, and respiration). This study aimed to validate the Chinese version of the FOUR score in patients with different levels of consciousness. The study had two phases: (1) translation of the FOUR score, and (2) assessment of its reliability and validity. The Chinese version of the FOUR score was developed according to a standardized protocol. One hundred-twenty consecutive patients with acute brain damage, admitted to Nanfang Hospital (Southern Medical University, Guangdong, China) from November 2014 to February 2015, were enrolled. The inter-rater agreement for the FOUR score and GCS was evaluated using intraclass correlation coefficient (ICC). Receiver operating characteristic (ROC) curves were established to determine the scales' abilities to predict outcome. The rater agreement was excellent both for FOUR (ICC = 0.970; p < 0.001) and GCS (ICC = 0.958; p < 0.001). The FOUR score yielded an excellent test-retest reliability (ICC = 0.930; p < 0.001). Spearman's correlation coefficients between GCS and the FOUR score were high: r = 0.932, first rating; r = 0.887, second rating (all p < 0.001). Areas under the curve (AUC) for mortality were 0.834 (95 % CI, 0.740-0.928) and 0.815 (95 % CI, 0.723-0.908) for the FOUR score and GCS, respectively. The Chinese version of the FOUR score is a reliable scale for evaluating the level of consciousness in patients with acute brain injury.

  20. Reliability of Measurement of Glenohumeral Internal Rotation, External Rotation, and Total Arc of Motion in 3 Test Positions

    PubMed Central

    Kevern, Mark A.; Beecher, Michael; Rao, Smita

    2014-01-01

    Context: Athletes who participate in throwing and racket sports consistently demonstrate adaptive changes in glenohumeral-joint internal and external rotation in the dominant arm. Measurements of these motions have demonstrated excellent intrarater and poor interrater reliability. Objective: To determine intrarater reliability, interrater reliability, and standard error of measurement for shoulder internal rotation, external rotation, and total arc of motion using an inclinometer in 3 testing procedures in National Collegiate Athletic Association Division I baseball and softball athletes. Design: Cross-sectional study. Setting: Athletic department. Patients or Other Participants Thirty-eight players participated in the study. Shoulder internal rotation, external rotation, and total arc of motion were measured by 2 investigators in 3 test positions. The standard supine position was compared with a side-lying test position, as well as a supine test position without examiner overpressure. Results: Excellent intrarater reliability was noted for all 3 test positions and ranges of motion, with intraclass correlation coefficient values ranging from 0.93 to 0.99. Results for interrater reliability were less favorable. Reliability for internal rotation was highest in the side-lying position (0.68) and reliability for external rotation and total arc was highest in the supine-without-overpressure position (0.774 and 0.713, respectively). The supine-with-overpressure position yielded the lowest interrater reliability results in all positions. The side-lying position had the most consistent results, with very little variation among intraclass correlation coefficient values for the various test positions. Conclusions: The results of our study clearly indicate that the side-lying test procedure is of equal or greater value than the traditional supine-with-overpressure method. PMID:25188316

  1. W5″ Test: A simple method for measuring mean power output in the bench press exercise.

    PubMed

    Tous-Fajardo, Julio; Moras, Gerard; Rodríguez-Jiménez, Sergio; Gonzalo-Skok, Oliver; Busquets, Albert; Mujika, Iñigo

    2016-11-01

    The aims of the present study were to assess the validity and reliability of a novel simple test [Five Seconds Power Test (W5″ Test)] for estimating the mean power output during the bench press exercise at different loads, and its sensitivity to detect training-induced changes. Thirty trained young men completed as many repetitions as possible in a time of ≈5 s at 25%, 45%, 65% and 85% of one-repetition maximum (1RM) in two test sessions separated by four days. The number of repetitions, linear displacement of the bar and time needed to complete the test were recorded by two independent testers, and a linear encoder was used as the criterion measure. For each load, the mean power output was calculated in the W5″ Test as mechanical work per time unit and compared with that obtained from the linear encoder. Subsequently, 20 additional subjects (10 training group vs. 10 control group) were assessed before and after completing a seven-week training programme designed to improve maximal power. Results showed that both assessment methods correlated highly in estimating mean power output at different loads (r range: 0.86-0.94; p < .01) and detecting training-induced changes (R(2): 0.78). Good to excellent intra-tester (intraclass correlation coefficient (ICC) range: 0.81-0.97) and excellent inter-tester (ICC range: 0.96-0.99; coefficient of variation range: 2.4-4.1%) reliability was found for all loads. The W5″ Test was shown to be a valid, reliable and sensitive method for measuring mean power output during the bench press exercise in subjects who have previous resistance training experience.

  2. Validation of the Parental-Caregiver Perceptions Questionnaire: agreement between parental and child reports.

    PubMed

    Barbosa, Taís de Souza; Gavião, Maria Beatriz Duarte

    2015-01-01

    To test the validity and reliability of Brazilian Portuguese version of the Parental-Caregiver Perceptions Questionnaire (P-CPQ) (Aim 1) and to assess the agreement between parents and children concerning the child's oral health-related quality of life (OHRQoL) (Aim 2). The P-CPQ and the Brazilian Portuguese versions of the Child Perceptions Questionnaires (CPQ8-10 and CPQ11-14 ) were used. Objective 1 addressed in the study that involved 210 (validity and internal reliability) and 20 (test-retest reliability) parents and Objective 2 in the study that involved 210 pairs of parents and children. Construct validity was calculated using the Spearman's correlation and the Mann-Whitney/Kruskal-Wallis tests. Reliability was determined using Cronbach's alpha and intraclass correlation coefficient (ICC). Agreement between overall and subscale scores derived from the P-CPQ and CPQ was assessed in comparison and correlation analyses. The P-CPQ discriminated among the categories of malocclusion and dmft. The P-CPQ showed good construct validity, good internal consistency reliability, and excellent test-retest reliability. There was systematic under- and overreporting in parents' assessments for younger and older children, respectively. However, the magnitude of the directional differences was just small. At individual level, agreement between parents and children was excellent. However, it ranged from excellent to moderate or substantial in subscales for CPQ8-10 and CPQ11-14 groups, respectively. The Portuguese version of P-CPQ is valid and reliable. Some parents have limited knowledge about child OHRQoL. Given that parental and child reports measure different realities concerning the child's OHRQoL, information provided by parents can complement the child's evaluation. © 2015 American Association of Public Health Dentistry.

  3. Manual muscle testing and hand-held dynamometry in people with inflammatory myopathy: An intra- and interrater reliability and validity study

    PubMed Central

    Baschung Pfister, Pierrette; Sterkele, Iris; Maurer, Britta; de Bie, Rob A.; Knols, Ruud H.

    2018-01-01

    Manual muscle testing (MMT) and hand-held dynamometry (HHD) are commonly used in people with inflammatory myopathy (IM), but their clinimetric properties have not yet been sufficiently studied. To evaluate the reliability and validity of MMT and HHD, maximum isometric strength was measured in eight muscle groups across three measurement events. To evaluate reliability of HHD, intra-class correlation coefficients (ICC), the standard error of measurements (SEM) and smallest detectable changes (SDC) were calculated. To measure reliability of MMT linear Cohen`s Kappa was computed for single muscle groups and ICC for total score. Additionally, correlations between MMT8 and HHD were evaluated with Spearman Correlation Coefficients. Fifty people with myositis (56±14 years, 76% female) were included in the study. Intra-and interrater reliability of HHD yielded excellent ICCs (0.75–0.97) for all muscle groups, except for interrater reliability of ankle extension (0.61). The corresponding SEMs% ranged from 8 to 28% and the SDCs% from 23 to 65%. MMT8 total score revealed excellent intra-and interrater reliability (ICC>0.9). Intrarater reliability of single muscle groups was substantial for shoulder and hip abduction, elbow and neck flexion, and hip extension (0.64–0.69); moderate for wrist (0.53) and knee extension (0.49) and fair for ankle extension (0.35). Interrater reliability was moderate for neck flexion (0.54) and hip abduction (0.44); fair for shoulder abduction, elbow flexion, wrist and ankle extension (0.20–0.33); and slight for knee extension (0.08). Correlations between the two tests were low for wrist, knee, ankle, and hip extension; moderate for elbow flexion, neck flexion and hip abduction; and good for shoulder abduction. In conclusion, the MMT8 total score is a reliable assessment to consider general muscle weakness in people with myositis but not for single muscle groups. In contrast, our results confirm that HHD can be recommended to evaluate strength of single muscle groups. PMID:29596450

  4. Assessment of the accuracy of a new tool for the screening of smartphone addiction.

    PubMed

    Khoury, Julia Machado; de Freitas, André Augusto Corrêa; Roque, Marco Antônio Valente; Albuquerque, Maicon Rodrigues; das Neves, Maila de Castro Lourenço; Garcia, Frederico Duarte

    2017-01-01

    To translate, adapt and validate the Smartphone Addiction Inventory (SPAI) in a Brazilian population of young adults. We employed the translation and back-translation method for the adaptation of the Brazilian version SPAI (SPAI-BR). The sample consisted of 415 university students. Data was collected through an electronic questionnaire, which consisted of the SPAI-BR and the Goodman Criteria (gold standard). The retests were carried out 10-15 days after the initial tests with 130 individuals. The SPAI-BR maintained semantic, idiomatic and conceptual equivalences from the original scale. The Confirmatory Factor Analysis confirmed the One-factor model of the SPAI with good fit indexes (x2 = 767.861, CFI = 0.913, TLI = 0.905, RMSE = 0.061, WRMR = 1.465). The Kuder-Richardson Coefficient showed good internal consistency. The analysis of the ROC curve established an area under the curve of 86.38%. The Intraclass-Correlation Coefficient of 0.926 between the test and the retest demonstrated an excellent temporal stability. The high correlation between SPAI-BR and the Goodman Criteria (rs = 0.750) established the convergent validity. The SPAI-BR is a valid and reliable tool for the detection of Smartphone Addiction in Brazilian university students.

  5. Performance Evaluation of the Sysmex CS-5100 Automated Coagulation Analyzer.

    PubMed

    Chen, Liming; Chen, Yu

    2015-01-01

    Coagulation testing is widely applied clinically, and laboratories increasingly demand automated coagulation analyzers with short turn-around times and high-throughput. The purpose of this study was to evaluate the performance of the Sysmex CS-5100 automated coagulation analyzer for routine use in a clinical laboratory. The prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (APTT), fibrinogen (Fbg), and D-dimer were compared between the Sysmex CS-5100 and Sysmex CA-7000 analyzers, and the imprecision, comparison, throughput, STAT function, and performance for abnormal samples were measured in each. The within-run and between-run coefficients of variation (CV) for the PT, APTT, INR, and D-dimer analyses showed excellent results both in the normal and pathologic ranges. The correlation coefficients between the Sysmex CS-5100 and Sysmex CA-7000 were highly correlated. The throughput of the Sysmex CS-5100 was faster than that of the Sysmex CA-7000. There was no interference at all by total bilirubin concentrations and triglyceride concentrations in the Sysmex CS-5100 analyzer. We demonstrated that the Sysmex CS-5100 performs with satisfactory imprecision and is well suited for coagulation analysis in laboratories processing large sample numbers and icteric and lipemic samples.

  6. A quick and reliable procedure for assessing foot alignment in athletes.

    PubMed

    De Michelis Mendonça, Luciana; Bittencourt, Natália Franco Netto; Amaral, Giovanna Mendes; Diniz, Lívia Santos; Souza, Thales Rezende; da Fonseca, Sérgio Teixeira

    2013-01-01

    Quick procedures with proper psychometric properties that can capture the combined alignment of the foot-ankle complex in a position that may be more representative of the status of the lower limb during ground contact are essential for assessing a large group of athletes. The assessed lower limb was positioned with the calcaneus surface facing upward in a way that all of the marks could be seen at the center of the camera display. After guaranteeing maintenance of the foot at 90° of dorsiflexion actively sustained by the athlete, the examiner took the picture of the foot-ankle alignment. Intraclass correlation coefficients ranging from 0.82 to 0.93 demonstrated excellent intratester and intertester reliability for the proposed measurements of forefoot, rearfoot, and shank-forefoot alignments. The intraclass correlation coefficient between the shank-forefoot measures and the sum of the rearfoot and forefoot measures was 0.98, suggesting that the shank-forefoot alignment measures can represent the combined rearfoot and forefoot alignments. This study describes a reliable and practical measurement procedure for rearfoot, forefoot, and shank-forefoot alignments that can be applied to clinical and research situations as a screening procedure for risk factors for lower-limb injuries in athletes.

  7. Inter-rater reliability of the Sødring Motor Evaluation of Stroke patients (SMES).

    PubMed

    Halsaa, K E; Sødring, K M; Bjelland, E; Finsrud, K; Bautz-Holter, E

    1999-12-01

    The Sødring Motor Evaluation of Stroke patients is an instrument for physiotherapists to evaluate motor function and activities in stroke patients. The rating reflects quality as well as quantity of the patient's unassisted performance within three domains: leg, arm and gross function. The inter-rater reliability of the method was studied in a sample of 30 patients admitted to a stroke rehabilitation unit. Three therapists were involved in the study; two therapists assessed the same patient on two consecutive days in a balanced design. Cohen's weighted kappa and McNemar's test of symmetry were used as measures of item reliability, and the intraclass correlation coefficient was used to express the reliability of the sumscores. For 24 out of 32 items the weighted kappa statistic was excellent (0.75-0.98), while 7 items had a kappa statistic within the range 0.53-0.74 (fair to good). The reliability of one item was poor (0.13). The intraclass correlation coefficient for the three sumscores was 0.97, 0.91 and 0.97. We conclude that the Sødring Motor Evaluation of Stroke patients is a reliable measure of motor function in stroke patients undergoing rehabilitation.

  8. Study on fast measurement of sugar content of yogurt using Vis/NIR spectroscopy techniques

    NASA Astrophysics Data System (ADS)

    He, Yong; Feng, Shuijuan; Wu, Di; Li, Xiaoli

    2006-09-01

    In order to measuring the sugar content of yogurt rapidly, a fast measurement of sugar content of yogurt using Vis/NIR-spectroscopy techniques was established. 25 samples selected separately from five different brands of yogurt were measured by Vis/NIR-spectroscopy. The sugar content of yogurt on positions scanned by spectrum were measured by a sugar content meter. The mathematical model between sugar content and Vis/NIR spectral measurements was established and developed based on partial least squares (PLS). The correlation coefficient of sugar content based on PLS model is more than 0.894, and standard error of calibration (SEC) is 0.356, standard error of prediction (SEP) is 0.389. Through predicting the sugar content quantitatively of 35 samples of yogurt from 5 different brands, the correlation coefficient between predictive value and measured value of those samples is more than 0.934. The results show the good to excellent prediction performance. The Vis/NIR spectroscopy technique had significantly greater accuracy for determining the sugar content. It was concluded that the Vis/NIRS measurement technique seems reliable to assess the fast measurement of sugar content of yogurt, and a new method for the measurement of sugar content of yogurt was established.

  9. Physicochemical properties of polycyclic aromatic hydrocarbons: Aqueous solubilities, n-octanol/water partition coefficients, and Henry`s law constants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maagd, P.G.J. de; Opperhuizen, A.; Sijm, D.T.H.M.

    Aqueous solubilities, n-octanol/water partition coefficients (K{sub ow}S), and Henry`s law constants were determined for a range of polycyclic aromatic hydrocarbons (PAHs) using a generator-column, slow-stirring, and gas-purge method, respectively. The currently obtained data were compared to available literature data. For seven of the PAHs no K{sub ow}S previously were determined with the slow-stirring method. For four of the PAHs the present study reports the first experimental Henry`s law constants. Relationships between subcooled liquid solubilities, K{sub ow}S, and Henry`s law constants as a function of molar volume are discussed. A consistent data set was obtained, for which an excellent correlation wasmore » found between subcooled liquid solubility and molar volume. A linear fit did not accurately describe the relationship between log K{sub ow} and molar volume. This is probably due to a decreasing solubility in n-octanol with increasing molar volume. Finally, a high correlation was found between Henry`s law constant and molar volume. The presently obtained dataset can be used to predict the fate and behavior of unsubstituted homocyclic PAHs.« less

  10. Assessing patients' experiences with communication across the cancer care continuum.

    PubMed

    Mazor, Kathleen M; Street, Richard L; Sue, Valerie M; Williams, Andrew E; Rabin, Borsika A; Arora, Neeraj K

    2016-08-01

    To evaluate the relevance, performance and potential usefulness of the Patient Assessment of cancer Communication Experiences (PACE) items. Items focusing on specific communication goals related to exchanging information, fostering healing relationships, responding to emotions, making decisions, enabling self-management, and managing uncertainty were tested via a retrospective, cross-sectional survey of adults who had been diagnosed with cancer. Analyses examined response frequencies, inter-item correlations, and coefficient alpha. A total of 366 adults were included in the analyses. Relatively few selected Does Not Apply, suggesting that items tap relevant communication experiences. Ratings of whether specific communication goals were achieved were strongly correlated with overall ratings of communication, suggesting item content reflects important aspects of communication. Coefficient alpha was ≥.90 for each item set, indicating excellent reliability. Variations in the percentage of respondents selecting the most positive response across items suggest results can identify strengths and weaknesses. The PACE items tap relevant, important aspects of communication during cancer care, and may be useful to cancer care teams desiring detailed feedback. The PACE is a new tool for eliciting patients' perspectives on communication during cancer care. It is freely available online for practitioners, researchers and others. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Validation of image analysis techniques to measure skin aging features from facial photographs.

    PubMed

    Hamer, M A; Jacobs, L C; Lall, J S; Wollstein, A; Hollestein, L M; Rae, A R; Gossage, K W; Hofman, A; Liu, F; Kayser, M; Nijsten, T; Gunn, D A

    2015-11-01

    Accurate measurement of the extent skin has aged is crucial for skin aging research. Image analysis offers a quick and consistent approach for quantifying skin aging features from photographs, but is prone to technical bias and requires proper validation. Facial photographs of 75 male and 75 female North-European participants, randomly selected from the Rotterdam Study, were graded by two physicians using photonumeric scales for wrinkles (full face, forehead, crow's feet, nasolabial fold and upper lip), pigmented spots and telangiectasia. Image analysis measurements of the same features were optimized using photonumeric grades from 50 participants, then compared to photonumeric grading in the 100 remaining participants stratified by sex. The inter-rater reliability of the photonumeric grades was good to excellent (intraclass correlation coefficients 0.65-0.93). Correlations between the digital measures and the photonumeric grading were moderate to excellent for all the wrinkle comparisons (Spearman's rho ρ = 0.52-0.89) bar the upper lip wrinkles in the men (fair, ρ = 0.30). Correlations were moderate to good for pigmented spots and telangiectasia (ρ = 0.60-0.75). These comparisons demonstrate that all the image analysis measures, bar the upper lip measure in the men, are suitable for use in skin aging research and highlight areas of improvement for future refinements of the techniques. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons.

  12. Reliability and criterion validity of measurements using a smart phone-based measurement tool for the transverse rotation angle of the pelvis during single-leg lifting.

    PubMed

    Jung, Sung-Hoon; Kwon, Oh-Yun; Jeon, In-Cheol; Hwang, Ui-Jae; Weon, Jong-Hyuck

    2018-01-01

    The purposes of this study were to determine the intra-rater test-retest reliability of a smart phone-based measurement tool (SBMT) and a three-dimensional (3D) motion analysis system for measuring the transverse rotation angle of the pelvis during single-leg lifting (SLL) and the criterion validity of the transverse rotation angle of the pelvis measurement using SBMT compared with a 3D motion analysis system (3DMAS). Seventeen healthy volunteers performed SLL with their dominant leg without bending the knee until they reached a target placed 20 cm above the table. This study used a 3DMAS, considered the gold standard, to measure the transverse rotation angle of the pelvis to assess the criterion validity of the SBMT measurement. Intra-rater test-retest reliability was determined using the SBMT and 3DMAS using intra-class correlation coefficient (ICC) [3,1] values. The criterion validity of the SBMT was assessed with ICC [3,1] values. Both the 3DMAS (ICC = 0.77) and SBMT (ICC = 0.83) showed excellent intra-rater test-retest reliability in the measurement of the transverse rotation angle of the pelvis during SLL in a supine position. Moreover, the SBMT showed an excellent correlation with the 3DMAS (ICC = 0.99). Measurement of the transverse rotation angle of the pelvis using the SBMT showed excellent reliability and criterion validity compared with the 3DMAS.

  13. CROSS-CULTURAL ADAPTATION AND VALIDATION OF THE ITCHING SEVERITY SCALE IN CHILDREN AND ADOLESCENTS WITH ATOPIC DERMATITIS.

    PubMed

    Bruscky, Dayanne Mota Veloso; Melo, Ana Caroline Cavalcanti Dela Bianca; Sarinho, Emanuel Sávio Cavalcanti

    2017-01-01

    To translate, adapt and validate the Itch Severity Scale to a Brazilian version (ISS-Ped) in order to measure the severity of pruritus in children and adolescents with atopic dermatitis. This is a methodological study of validation of an instrument following recommended protocols. The translated version was evaluated by a group of experts including one professional with experience in instrument validation, three English teachers, one linguistics teacher and seven allergists. After this, the scale was applied to 42 parents of children aged between 2 and 18 years old with atopic dermatitis, and 42 parents of children without pruritic diseases. Results were evaluated according to the severity of atopic dermatitis and disease control, and they were compared between groups with and without atopic dermatitis. More than 90% of the questions were clear to the parents. The ISS-Ped showed a strong positive correlation with the severity of atopic dermatitis (Pearson: 0.74; p<0.001) and a good correlation with the control of dermatitis (point-biserial correlation coefficient: 0.65; p<0.001). The scale showed excellent internal consistency (Cronbach's α: 0.96) and adequate test and retest agreement (95% confidence interval of intraclass correlation coefficient: 0.89-0.99; p<0.001). The ISS-Ped is a feasible, valid, reliable and satisfactorily equivalent. The translated scale was appropriate to assess the severity of itching in children and adolescents with eczema, allowing comparisons in the clinical practice and in the research setting.

  14. Automated cerebral infarct volume measurement in follow-up noncontrast CT scans of patients with acute ischemic stroke.

    PubMed

    Boers, A M; Marquering, H A; Jochem, J J; Besselink, N J; Berkhemer, O A; van der Lugt, A; Beenen, L F; Majoie, C B

    2013-08-01

    Cerebral infarct volume as observed in follow-up CT is an important radiologic outcome measure of the effectiveness of treatment of patients with acute ischemic stroke. However, manual measurement of CIV is time-consuming and operator-dependent. The purpose of this study was to develop and evaluate a robust automated measurement of the CIV. The CIV in early follow-up CT images of 34 consecutive patients with acute ischemic stroke was segmented with an automated intensity-based region-growing algorithm, which includes partial volume effect correction near the skull, midline determination, and ventricle and hemorrhage exclusion. Two observers manually delineated the CIV. Interobserver variability of the manual assessments and the accuracy of the automated method were evaluated by using the Pearson correlation, Bland-Altman analysis, and Dice coefficients. The accuracy was defined as the correlation with the manual assessment as a reference standard. The Pearson correlation for the automated method compared with the reference standard was similar to the manual correlation (R = 0.98). The accuracy of the automated method was excellent with a mean difference of 0.5 mL with limits of agreement of -38.0-39.1 mL, which were more consistent than the interobserver variability of the 2 observers (-40.9-44.1 mL). However, the Dice coefficients were higher for the manual delineation. The automated method showed a strong correlation and accuracy with the manual reference measurement. This approach has the potential to become the standard in assessing the infarct volume as a secondary outcome measure for evaluating the effectiveness of treatment.

  15. Octanol-Water Partition Coefficient from 3D-RISM-KH Molecular Theory of Solvation with Partial Molar Volume Correction.

    PubMed

    Huang, WenJuan; Blinov, Nikolay; Kovalenko, Andriy

    2015-04-30

    The octanol-water partition coefficient is an important physical-chemical characteristic widely used to describe hydrophobic/hydrophilic properties of chemical compounds. The partition coefficient is related to the transfer free energy of a compound from water to octanol. Here, we introduce a new protocol for prediction of the partition coefficient based on the statistical-mechanical, 3D-RISM-KH molecular theory of solvation. It was shown recently that with the compound-solvent correlation functions obtained from the 3D-RISM-KH molecular theory of solvation, the free energy functional supplemented with the correction linearly related to the partial molar volume obtained from the Kirkwood-Buff/3D-RISM theory, also called the "universal correction" (UC), provides accurate prediction of the hydration free energy of small compounds, compared to explicit solvent molecular dynamics [ Palmer , D. S. ; J. Phys.: Condens. Matter 2010 , 22 , 492101 ]. Here we report that with the UC reparametrized accordingly this theory also provides an excellent agreement with the experimental data for the solvation free energy in nonpolar solvent (1-octanol) and so accurately predicts the octanol-water partition coefficient. The performance of the Kovalenko-Hirata (KH) and Gaussian fluctuation (GF) functionals of the solvation free energy, with and without UC, is tested on a large library of small compounds with diverse functional groups. The best agreement with the experimental data for octanol-water partition coefficients is obtained with the KH-UC solvation free energy functional.

  16. Psychometric validation of a sexual quality of life questionnaire for use in men with premature ejaculation or erectile dysfunction.

    PubMed

    Abraham, Lucy; Symonds, Tara; Morris, Mark F

    2008-03-01

    An instrument that can systematically capture the impact of sexual dysfunction on quality of life (QoL) in men is needed. To psychometrically validate a sexual QoL instrument for men (SQOL-M) with premature ejaculation (PE) or erectile dysfunction (ED). The main assessment populations were men participating in clinical trials of treatments for PE or ED. Men with PE had a confirmed intravaginal ejaculatory latency time of < or = 2 minutes in > or = 70% of attempts. Men with ED had a score of > 21 on the International Index of Erectile Function (IIEF). Confirmatory psychometric testing was conducted in further groups of men with PE. The internal consistency, convergent and discriminant validity, test-retest reliability, and known-groups validity of the instrument were assessed. An 11-item version of the SQOL-M was produced following factor analyses on men with either PE or ED. Psychometric testing showed no overlap between items and good item-total correlations. Factor analysis confirmed a one-factor solution. Excellent internal consistency was demonstrated, with a Cronbach's alpha of > or = 0.82 in all groups. In men reporting no change in their symptoms, the SQOL-M showed excellent test-retest reliability: the intraclass correlation coefficient was 0.77 for men with PE, and 0.79 for men with ED. Convergent validity was also good. In men with PE, the SQOL-M correlated with the satisfaction and distress domains of the Index of Premature Ejaculation. In men with ED, the SQOL-M correlated with the overall satisfaction domain of the IIEF. The measure also demonstrated excellent discriminant validity between men with PE or ED and men with no sexual dysfunction (P < 0.0001). The SQOL-M instrument is a useful tool for evaluating sexual QoL in men with PE and ED.

  17. Flammability Indices for Refrigerants

    NASA Astrophysics Data System (ADS)

    Kataoka, Osami

    This paper introduces a new index to classify flammable refrigerants. A question on flammability indices that ASHRAE employs arose from combustion test results of R152a and ammonia. Conventional methods of not only ASHRAE but also ISO and Japanese High-pressure gas safety law to classify the flammability of refrigerants are evaluated to show why these methods conflict with the test results. The key finding of this paper is that the ratio of stoichiometric concentration to LFL concentration (R factor) represents the test results most precisely. In addition, it has excellent correlation with other flammability parameters such as flame speed and pressure rise coefficient. Classification according to this index gives reasonable flammability order of substances including ammonia, R152a and carbon monoxide. Theoretical background why this index gives good correlation is also discussed as well as the insufficient part of this method.

  18. Chinese adaptation and validation of the patellofemoral pain severity scale.

    PubMed

    Cheung, Roy T H; Ngai, Shirley P C; Lam, Priscillia L; Chiu, Joseph K W; Fung, Eric Y H

    2013-05-01

    This study validated the Patellofemoral Pain Severity Scale translated into Chinese. The Chinese Patellofemoral Pain Severity Scale was translated from the original English version following standard forward and backward translation procedures recommended by the International Society for Pharmacoeconomics and Outcomes Research. The survey was then conducted in clinical settings by a questionnaire comprising the Chinese Patellofemoral Pain Severity Scale, Kujala Scale and Western Ontario and McMaster Universities (WOMAC) Osteoarthritis Index. Eighty-four Chinese reading patients with patellofemoral pain were recruited from physical therapy clinics. Internal consistency of the translated instrument was measured by Cronbach alpha. Convergent validity was examined by Spearman rank correlation coefficient (rho) tests by comparing its score with the validated Chinese version of the Kujala Scale and the WOMAC Osteoarthritis Index while the test-retest reliability was evaluated by administering the questionnaires twice. Cronbach alpha values of individual questions and their overall value were above 0.85. Strong association was found between the Chinese Patellofemoral Pain Severity Scale and the Kujala Scale (rho = -0.72, p < 0.001). Moderate correlation was also found between Chinese Patellofemoral Pain Severity Scale with the WOMAC Osteoarthritis Index (rho = 0.63, p < 0.001). Excellent test-retest reliability (Intraclass correlation coefficient = 0.98) was demonstrated. The Chinese translated version of the Patellofemoral Pain Severity Scale is a reliable and valid instrument for patients with patellofemoral pain.

  19. Influence of chain ordering on the selectivity of dipalmitoylphosphatidylcholine bilayer membranes for permeant size and shape.

    PubMed Central

    Xiang, T X; Anderson, B D

    1998-01-01

    The effects of lipid chain packing and permeant size and shape on permeability across lipid bilayers have been investigated in gel and liquid crystalline dipalmitoylphosphatidylcholine (DPPC) bilayers by a combined NMR line-broadening/dynamic light scattering method using seven short-chain monocarboxylic acids (formic acid, acetic acid, propionic acid, butyric acid, valeric acid, isovaleric acid, and trimethylacetic acid) as permeants. The experimental permeability coefficients are compared with the predictions of a bulk solubility diffusion model in which the bilayer membrane is represented as a slab of bulk hexadecane. Deviations of the observed permeability coefficients (Pm) from the values predicted from solubility diffusion theory (Po) lead to the determination of a correction factor, the permeability decrement f (= Pm/Po), to account for the effects of chain ordering. The natural logarithm of f has been found to correlate linearly with the inverse of the bilayer free surface area with slopes of 25 +/- 2, 36 +/- 3, 45 +/- 8, 32 +/- 12, 33 +/- 4, 49 +/- 12, and 75 +/- 6 A2 for formic acid, acetic acid, propionic acid, butyric acid, valeric acid, isovaleric acid, and trimethylacetic acid, respectively. The slope, which measures the sensitivity of the permeability coefficient of a given permeant to bilayer chain packing, exhibits an excellent linear correlation (r = 0.94) with the minimum cross-sectional area of the permeant and a poor correlation (r = 0.59) with molecular volume, suggesting that in the bilayer interior the permeants prefer to move with their long principal axis along the bilayer normal. Based on these studies, a permeability model combining the effects of bilayer chain packing and permeant size and shape on permeability across lipid membranes is developed. PMID:9826590

  20. Measuring joint kinematics of treadmill walking and running: Comparison between an inertial sensor based system and a camera-based system.

    PubMed

    Nüesch, Corina; Roos, Elena; Pagenstert, Geert; Mündermann, Annegret

    2017-05-24

    Inertial sensor systems are becoming increasingly popular for gait analysis because their use is simple and time efficient. This study aimed to compare joint kinematics measured by the inertial sensor system RehaGait® with those of an optoelectronic system (Vicon®) for treadmill walking and running. Additionally, the test re-test repeatability of kinematic waveforms and discrete parameters for the RehaGait® was investigated. Twenty healthy runners participated in this study. Inertial sensors and reflective markers (PlugIn Gait) were attached according to respective guidelines. The two systems were started manually at the same time. Twenty consecutive strides for walking and running were recorded and each software calculated sagittal plane ankle, knee and hip kinematics. Measurements were repeated after 20min. Ensemble means were analyzed calculating coefficients of multiple correlation for waveforms and root mean square errors (RMSE) for waveforms and discrete parameters. After correcting the offset between waveforms, the two systems/models showed good agreement with coefficients of multiple correlation above 0.950 for walking and running. RMSE of the waveforms were below 5° for walking and below 8° for running. RMSE for ranges of motion were between 4° and 9° for walking and running. Repeatability analysis of waveforms showed very good to excellent coefficients of multiple correlation (>0.937) and RMSE of 3° for walking and 3-7° for running. These results indicate that in healthy subjects sagittal plane joint kinematics measured with the RehaGait® are comparable to those using a Vicon® system/model and that the measured kinematics have a good repeatability, especially for walking. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Chemical Potentials, Activity Coefficients, and Solubility in Aqueous NaCl Solutions: Prediction by Polarizable Force Fields.

    PubMed

    Moučka, Filip; Nezbeda, Ivo; Smith, William R

    2015-04-14

    We describe a computationally efficient molecular simulation methodology for calculating the concentration dependence of the chemical potentials of both solute and solvent in aqueous electrolyte solutions, based on simulations of the salt chemical potential alone. We use our approach to study the predictions for aqueous NaCl solutions at ambient conditions of these properties by the recently developed polarizable force fields (FFs) AH/BK3 of Kiss and Baranyai (J. Chem. Phys. 2013, 138, 204507) and AH/SWM4-DP of Lamoureux and Roux (J. Phys. Chem. B 2006, 110, 3308 - 3322) and by the nonpolarizable JC FF of Joung and Cheatham tailored to SPC/E water (J. Phys. Chem. B 2008, 112, 9020 - 9041). We also consider their predictions of the concentration dependence of the electrolyte activity coefficient, the crystalline solid chemical potential, the electrolyte solubility, and the solution specific volume. We first highlight the disagreement in the literature concerning calculations of solubility by means of molecular simulation in the case of the JC FF and provide strong evidence of the correctness of our methodology based on recent independently obtained results for this important test case. We then compare the predictions of the three FFs with each other and with experiment and draw conclusions concerning their relative merits, with particular emphasis on the salt chemical potential and activity coefficient vs concentration curves and their derivatives. The latter curves have only previously been available from Kirkwood-Buff integrals, which require approximate numerical integrations over system pair correlation functions at each concentration. Unlike the case of the other FFs, the AH/BK3 curves are nearly parallel to the corresponding experimental curves at moderate and higher concentrations. This leads to an excellent prediction of the water chemical potential via the Gibbs-Duhem equation and enables the activity coefficient curve to be brought into excellent agreement with experiment by incorporating an appropriate value of the standard state chemical potential in the Henry Law convention.

  2. A reliability assessment of constrained spherical deconvolution-based diffusion-weighted magnetic resonance imaging in individuals with chronic stroke.

    PubMed

    Snow, Nicholas J; Peters, Sue; Borich, Michael R; Shirzad, Navid; Auriat, Angela M; Hayward, Kathryn S; Boyd, Lara A

    2016-01-15

    Diffusion-weighted magnetic resonance imaging (DW-MRI) is commonly used to assess white matter properties after stroke. Novel work is utilizing constrained spherical deconvolution (CSD) to estimate complex intra-voxel fiber architecture unaccounted for with tensor-based fiber tractography. However, the reliability of CSD-based tractography has not been established in people with chronic stroke. Establishing the reliability of CSD-based DW-MRI in chronic stroke. High-resolution DW-MRI was performed in ten adults with chronic stroke during two separate sessions. Deterministic region of interest-based fiber tractography using CSD was performed by two raters. Mean fractional anisotropy (FA), apparent diffusion coefficient (ADC), tract number, and tract volume were extracted from reconstructed fiber pathways in the corticospinal tract (CST) and superior longitudinal fasciculus (SLF). Callosal fiber pathways connecting the primary motor cortices were also evaluated. Inter-rater and test-retest reliability were determined by intra-class correlation coefficients (ICCs). ICCs revealed excellent reliability for FA and ADC in ipsilesional (0.86-1.00; p<0.05) and contralesional hemispheres (0.94-1.00; p<0.0001), for CST and SLF fibers; and excellent reliability for all metrics in callosal fibers (0.85-1.00; p<0.05). ICC ranged from poor to excellent for tract number and tract volume in ipsilesional (-0.11 to 0.92; p≤0.57) and contralesional hemispheres (-0.27 to 0.93; p≤0.64), for CST and SLF fibers. Like other select DW-MRI approaches, CSD-based tractography is a reliable approach to evaluate FA and ADC in major white matter pathways, in chronic stroke. Future work should address the reproducibility and utility of CSD-based metrics of tract number and tract volume. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Scan-rescan reproducibility of segmental aortic wall shear stress as assessed by phase-specific segmentation with 4D flow MRI in healthy volunteers.

    PubMed

    van der Palen, Roel L F; Roest, Arno A W; van den Boogaard, Pieter J; de Roos, Albert; Blom, Nico A; Westenberg, Jos J M

    2018-05-26

    The aim was to investigate scan-rescan reproducibility and observer variability of segmental aortic 3D systolic wall shear stress (WSS) by phase-specific segmentation with 4D flow MRI in healthy volunteers. Ten healthy volunteers (age 26.5 ± 2.6 years) underwent aortic 4D flow MRI twice. Maximum 3D systolic WSS (WSSmax) and mean 3D systolic WSS (WSSmean) for five thoracic aortic segments over five systolic cardiac phases by phase-specific segmentations were calculated. Scan-rescan analysis and observer reproducibility analysis were performed. Scan-rescan data showed overall good reproducibility for WSSmean (coefficient of variation, COV 10-15%) with moderate-to-strong intraclass correlation coefficient (ICC 0.63-0.89). The variability in WSSmax was high (COV 16-31%) with moderate-to-good ICC (0.55-0.79) for different aortic segments. Intra- and interobserver reproducibility was good-to-excellent for regional aortic WSSmax (ICC ≥ 0.78; COV ≤ 17%) and strong-to-excellent for WSSmean (ICC ≥ 0.86; COV ≤ 11%). In general, ascending aortic segments showed more WSSmax/WSSmean variability compared to aortic arch or descending aortic segments for scan-rescan, intraobserver and interobserver comparison. Scan-rescan reproducibility was good for WSSmean and moderate for WSSmax for all thoracic aortic segments over multiple systolic phases in healthy volunteers. Intra/interobserver reproducibility for segmental WSS assessment was good-to-excellent. Variability of WSSmax is higher and should be taken into account in case of individual follow-up or in comparative rest-stress studies to avoid misinterpretation.

  4. Validity and Reliability of a New Device (WIMU®) for Measuring Hamstring Muscle Extensibility.

    PubMed

    Muyor, José M

    2017-09-01

    The aims of the current study were 1) to evaluate the validity of the WIMU ® system for measuring hamstring muscle extensibility in the passive straight leg raise (PSLR) test using an inclinometer for the criterion and 2) to determine the test-retest reliability of the WIMU ® system to measure hamstring muscle extensibility during the PSLR test. 55 subjects were evaluated on 2 separate occasions. Data from a Unilever inclinometer and WIMU ® system were collected simultaneously. Intraclass correlation coefficients (ICCs) for the validity were very high (0.983-1); a very low systematic bias (-0.21°--0.42°), random error (0.05°-0.04°) and standard error of the estimate (0.43°-0.34°) were observed (left-right leg, respectively) between the 2 devices (inclinometer and the WIMU ® system). The R 2 between the devices was 0.999 (p<0.001) in both the left and right legs. The test-retest reliability of the WIMU ® system was excellent, with ICCs ranging from 0.972-0.995, low coefficients of variation (0.01%), and a low standard error of the estimate (0.19-0.31°). The WIMU ® system showed strong concurrent validity and excellent test-retest reliability for the evaluation of hamstring muscle extensibility in the PSLR test. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Measurement of sodium concentration in sweat samples: comparison of 5 analytical techniques.

    PubMed

    Goulet, Eric D B; Asselin, Audrey; Gosselin, Jonathan; Baker, Lindsay B

    2017-08-01

    Sweat sodium concentration (SSC) can be determined using different analytical techniques (ATs), which may have implications for athletes and scientists. This study compared the SSC measured with 5 ATs: ion chromatography (IChr), flame photometry (FP), direct (DISE) and indirect (IISE) ion-selective electrode, and ion conductivity (IC). Seventy sweat samples collected from 14 athletes were analyzed with 5 instruments: the 883 Basic IC Plus (IChr, reference instrument), AAnalyst 200 (FP), Cobas 6000 (IISE), Sweat-Chek (IC), and B-722 Laqua Twin (DISE). Instruments showed excellent relative (intraclass correlation coefficient (ICC) ≥ 0.999) and absolute (coefficient of variation (CV) ≤ 2.6%) reliability. Relative validity was also excellent between ATs (ICC ≥ 0.961). In regards to the inter-AT absolute validity, compared with IChr, standard error of the estimates were similar among ATs (2.8-3.8 mmol/L), but CV was lowest with DISE (3.9%), intermediate with IISE (7.6%), and FP (6.9%) and highest with IC (12.3%). In conclusion, SSC varies depending on the AT used to analyze samples. Therefore, results obtained from different ATs are scarcely comparable and should not be used interchangeably. Nevertheless, taking into account the normal variability in SSC (∼±12%), the imprecision of the recommendations deriving from FP, IISE, IC, and DISE should have trivial health and physiological consequences under most exercise circumstances.

  6. Detection of early psychotic symptoms: Validation of the Spanish version of the "Symptom Onset in Schizophrenia (SOS) inventory".

    PubMed

    Mezquida, Gisela; Cabrera, Bibiana; Martínez-Arán, Anabel; Vieta, Eduard; Bernardo, Miguel

    2018-03-01

    The period of subclinical signs that precedes the onset of psychosis is referred to as the prodrome or high-risk mental state. The "Symptom Onset in Schizophrenia (SOS) inventory" is an instrument to characterize and date the initial symptoms of a psychotic illness. The present study aims to provide reliability and validity data for clinical and research use of the Spanish version of the SOS. Thirty-six participants with a first-episode of psychosis meeting DSM-IV criteria for schizophrenia/schizoaffective/schizophreniform disorder were administered the translated SOS and other clinical assessments. The internal validity, intrarater and interrater reliability were studied. We found strong interrater reliability. To detect the presence/absence of prodromal symptoms, Kappa coefficients ranged between 0.8 and 0.7. Similarly, the raters obtained an excellent level of agreement regarding the onset of each symptom and the duration of symptoms until first treatment (intraclass correlation coefficients between 0.9 and 1.0). Cronbach's alpha was 0.9-1.0 for all the items. The interrater reliability and concurrent validity were also excellent in both cases. This study provides robust psychometric properties of the Spanish version of the SOS. The translated version is adequate in terms of good internal validity, intrarater and interrater reliability, and is as time-efficient as the original version. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Computerized Liver Volumetry on MRI by Using 3D Geodesic Active Contour Segmentation

    PubMed Central

    Huynh, Hieu Trung; Karademir, Ibrahim; Oto, Aytekin; Suzuki, Kenji

    2014-01-01

    OBJECTIVE Our purpose was to develop an accurate automated 3D liver segmentation scheme for measuring liver volumes on MRI. SUBJECTS AND METHODS Our scheme for MRI liver volumetry consisted of three main stages. First, the preprocessing stage was applied to T1-weighted MRI of the liver in the portal venous phase to reduce noise and produce the boundary-enhanced image. This boundary-enhanced image was used as a speed function for a 3D fast-marching algorithm to generate an initial surface that roughly approximated the shape of the liver. A 3D geodesic-active-contour segmentation algorithm refined the initial surface to precisely determine the liver boundaries. The liver volumes determined by our scheme were compared with those manually traced by a radiologist, used as the reference standard. RESULTS The two volumetric methods reached excellent agreement (intraclass correlation coefficient, 0.98) without statistical significance (p = 0.42). The average (± SD) accuracy was 99.4% ± 0.14%, and the average Dice overlap coefficient was 93.6% ± 1.7%. The mean processing time for our automated scheme was 1.03 ± 0.13 minutes, whereas that for manual volumetry was 24.0 ± 4.4 minutes (p < 0.001). CONCLUSION The MRI liver volumetry based on our automated scheme agreed excellently with reference-standard volumetry, and it required substantially less completion time. PMID:24370139

  8. Computerized liver volumetry on MRI by using 3D geodesic active contour segmentation.

    PubMed

    Huynh, Hieu Trung; Karademir, Ibrahim; Oto, Aytekin; Suzuki, Kenji

    2014-01-01

    Our purpose was to develop an accurate automated 3D liver segmentation scheme for measuring liver volumes on MRI. Our scheme for MRI liver volumetry consisted of three main stages. First, the preprocessing stage was applied to T1-weighted MRI of the liver in the portal venous phase to reduce noise and produce the boundary-enhanced image. This boundary-enhanced image was used as a speed function for a 3D fast-marching algorithm to generate an initial surface that roughly approximated the shape of the liver. A 3D geodesic-active-contour segmentation algorithm refined the initial surface to precisely determine the liver boundaries. The liver volumes determined by our scheme were compared with those manually traced by a radiologist, used as the reference standard. The two volumetric methods reached excellent agreement (intraclass correlation coefficient, 0.98) without statistical significance (p = 0.42). The average (± SD) accuracy was 99.4% ± 0.14%, and the average Dice overlap coefficient was 93.6% ± 1.7%. The mean processing time for our automated scheme was 1.03 ± 0.13 minutes, whereas that for manual volumetry was 24.0 ± 4.4 minutes (p < 0.001). The MRI liver volumetry based on our automated scheme agreed excellently with reference-standard volumetry, and it required substantially less completion time.

  9. Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients

    PubMed Central

    Yu, Sha-Sha; Song, Hui; Tang, Xin

    2017-01-01

    AIM To determine the repeatability of Ophtha Top topography and assess the consistency with intraocular lens (IOL)-Master and LenstarLS900 (Lenstar) in measuring corneal parameters among cataract patients. METHODS Totally 125 eyes were enrolled. Corneas were successively measured with Ophtha Top, IOL-Master and Lenstar at least three times. The flattest meridian power (Kf), the steepest meridian power (Ks), mean power (Km), J0 and J45 were recorded. Intra-class correlation coefficients (ICCs), the coefficient of variance (COV), within subject standard deviation (Sw), and test-retest repeatability (2.77Sw) were adopted to determine the repeatability. The 95% limit of agreement (95%LOA) and Bland-Altman plots were used to assess comparability. RESULTS Repeatability of Ophtha Top topography for measuring corneal parameters showed the ICCs were all above 0.93, 2.77Sw was lower than 0.31, and the COV of the Kf and Ks was lower than 0.25. The keratometric readings with Ophtha Top topography were flatter than with the IOL-Master and Lenstar devices, while the Pearson correlation coefficients were over 0.97. The J0 and J45 with Ophtha Top topography were smaller compared with Lenstar and IOL-Master, while was comparable between Lenstar and IOL-Master. CONCLUSION Ophtha Top topography shows excellent repeatability for measuring corneal parameters. However, differences between the Ophtha TOP topography and Lenstar, IOL-Master both in cornea curvature and the astigmatism should be noted clinically. PMID:29181314

  10. Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients.

    PubMed

    Yu, Sha-Sha; Song, Hui; Tang, Xin

    2017-01-01

    To determine the repeatability of Ophtha Top topography and assess the consistency with intraocular lens (IOL)-Master and LenstarLS900 (Lenstar) in measuring corneal parameters among cataract patients. Totally 125 eyes were enrolled. Corneas were successively measured with Ophtha Top, IOL-Master and Lenstar at least three times. The flattest meridian power (Kf), the steepest meridian power (Ks), mean power (Km), J0 and J45 were recorded. Intra-class correlation coefficients (ICCs), the coefficient of variance (COV), within subject standard deviation (Sw), and test-retest repeatability (2.77Sw) were adopted to determine the repeatability. The 95% limit of agreement (95%LOA) and Bland-Altman plots were used to assess comparability. Repeatability of Ophtha Top topography for measuring corneal parameters showed the ICCs were all above 0.93, 2.77Sw was lower than 0.31, and the COV of the Kf and Ks was lower than 0.25. The keratometric readings with Ophtha Top topography were flatter than with the IOL-Master and Lenstar devices, while the Pearson correlation coefficients were over 0.97. The J0 and J45 with Ophtha Top topography were smaller compared with Lenstar and IOL-Master, while was comparable between Lenstar and IOL-Master. Ophtha Top topography shows excellent repeatability for measuring corneal parameters. However, differences between the Ophtha TOP topography and Lenstar, IOL-Master both in cornea curvature and the astigmatism should be noted clinically.

  11. Stir bar sorptive extraction and high performance liquid chromatographic determination of carvedilol in human serum using two different polymeric phases and an ionic liquid as desorption solvent.

    PubMed

    Talebpour, Zahra; Taraji, Maryam; Adib, Nuoshin

    2012-05-04

    This article presents a method employing stir bar coated with a film of poly (methyl methacrylate/ethyleneglycol dimethacrylate) (PA-EG) and polydimethylsiloxane (PDMS) in combination with liquid desorption (LD) using ionic liquid, followed by high performance liquid chromatography (HPLC) equipped with ultraviolet (UV) detection for the determination of carvedilol in human serum samples. Stir bar sorptive extraction (SBSE) variables, such as desorption and extraction time and temperature, desorption solvent and pH of the matrix were optimized, in order to achieve suitable analytical sensitivity in a short period of time. Also, the concentration effect of 1-methyl-3-octylimidazolium tetrafluoroborate [Omim][BF4] ionic liquid on the efficiency of LD was investigated. A comparison between PA-EG/SBSE and PDMS/SBSE was made by calculating the experimental recovery and partition coefficient (K), where PA-EG phase demonstrated to be an excellent alternative for the enrichment of the carvedilol from serum samples. The effect of [Omim][BF4] on carryover was studied and no carryover was observed. Under optimized experimental conditions, the analytical performance showed excellent linear dynamic range, with correlation coefficients higher than 0.999 and limits of detection and quantification of 0.3 and 1.0 ng mL(-1), respectively. Intra- and inter-day recovery ranged from 94 to 103% and the coefficients of variations were less than 3.2%. The proposed method was shown to be simple, highly sensitive and suitable for the measurement of trace concentration levels of carvedilol in biological fluid media. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Comparison of Central Corneal Thickness Measured by Standard Ultrasound Pachymetry, Corneal Topography, Tono-Pachymetry and Anterior Segment Optical Coherence Tomography.

    PubMed

    González-Pérez, Javier; Queiruga Piñeiro, Juan; Sánchez García, Ángelx; González Méijome, José Manuel

    2018-04-10

    To compare central corneal thickness (CCT) measured by standard ultrasound pachymetry (USP), and three non-contact devices in healthy eyes. A cross-sectional study of CCT measurement in 52 eyes of 52 healthy volunteers was done by a single examiner at Ocular Surface and Contact Lens Laboratory. Three consecutive measurements were done by standard USP, non-contact tono-pachymeter, Pentacam corneal topographer, and Anterior Segment Optical Coherence Tomography (AS-OCT). The mean values were used for assessment. The results were compared using multivariate ANOVA, linear regression, and Pearson correlation. Agreement among the devices was analyzed using mean differences and Bland-Altman analysis with 95% limits of agreement (LoA). Finally, reliability was analyzed using intraclass correlation coefficient (ICC). Mean CCT by ultrasound pachymeter, tono-pachymeter, corneal topographer and AS-OCT were 558.9 ± 31.2 µm, 525.8 ± 43.1 µm, 550.4 ± 30.5 µm, and 545.9 ± 30.5 µm respectively. There was a significant positive correlation between AS-OCT and USP (Pearson correlation = 0.957, p < 0.001), corneal topography and USP (Pearson correlation = 0.965, p < 0.001), and corneal topography and AS-OCT (Pearson correlation = 0.965, p < 0.001). There was a lower correlation between CT-1P tono-pachymeter and the other three modalities. Intraclass correlation coefficients show an excellent reliability between pairs except for CT-1P against the other three instruments that were found moderate. CT-1P tono-pachymeter underestimates CCT measurements compared to Scheimpflug system, AS-OCT device, and USP. Mean CCT among USP, Pentacam and AS-OCT were comparable and had significant linear correlations. In clinical practice, these three modalities could be interchangeable in healthy patients.

  13. A new correlation coefficient for bivariate time-series data

    NASA Astrophysics Data System (ADS)

    Erdem, Orhan; Ceyhan, Elvan; Varli, Yusuf

    2014-11-01

    The correlation in time series has received considerable attention in the literature. Its use has attained an important role in the social sciences and finance. For example, pair trading in finance is concerned with the correlation between stock prices, returns, etc. In general, Pearson’s correlation coefficient is employed in these areas although it has many underlying assumptions which restrict its use. Here, we introduce a new correlation coefficient which takes into account the lag difference of data points. We investigate the properties of this new correlation coefficient. We demonstrate that it is more appropriate for showing the direction of the covariation of the two variables over time. We also compare the performance of the new correlation coefficient with Pearson’s correlation coefficient and Detrended Cross-Correlation Analysis (DCCA) via simulated examples.

  14. Reliability of Autism-Tics, AD/HD, and other Comorbidities (A-TAC) inventory in a test-retest design.

    PubMed

    Larson, Tomas; Kerekes, Nóra; Selinus, Eva Norén; Lichtenstein, Paul; Gumpert, Clara Hellner; Anckarsäter, Henrik; Nilsson, Thomas; Lundström, Sebastian

    2014-02-01

    The Autism-Tics, AD/HD, and other Comorbidities (A-TAC) inventory is used in epidemiological research to assess neurodevelopmental problems and coexisting conditions. Although the A-TAC has been applied in various populations, data on retest reliability are limited. The objective of the present study was to present additional reliability data. The A-TAC was administered by lay assessors and was completed on two occasions by parents of 400 individual twins, with an average interval of 70 days between test sessions. Intra- and inter-rater reliability were analysed with intraclass correlations and Cohen's kappa. A-TAC showed excellent test-retest intraclass correlations for both autism spectrum disorder and attention deficit hyperactivity disorder (each at .84). Most modules in the A-TAC had intra- and inter-rater reliability intraclass correlation coefficients of > or = .60. Cohen's kappa indi- cated acceptable reliability. The current study provides statistical evidence that the A-TAC yields good test-retest reliability in a population-based cohort of children.

  15. Cross-cultural adaptation and clinical evaluation of a Korean version of the disabilities of arm, shoulder, and hand outcome questionnaire (K-DASH).

    PubMed

    Lee, Joo-Yup; Lim, Jae-Young; Oh, Joo Han; Ko, Young-Mi

    2008-01-01

    We developed a Korean version of the disabilities of arm, shoulder, and hand outcome questionnaire (K-DASH) by performing cross-cultural adaptation and evaluated the reliability and validity of the K-DASH. The K-DASH, SF-36, and Visual Analog Scale (VAS) for pain were administered to 161 patients with arm, shoulder, and hand problems. The internal consistency of the disability/symptom scores of the K-DASH was high (Cronbach's alpha 0.94). The retest assessed 131 of the 161 patients. The intraclass correlation coefficient was 0.91. The construct validity was evaluated using the correlations between the K-DASH and the SF-36 and VAS. The physical and mental component summary scales of the SF-36 and the VAS at rest and during activity were significantly correlated with the DASH disability/symptom scores. Despite the linguistic and cultural differences, the reliability and validity of the K-DASH were just as excellent as those of the original DASH.

  16. Psychometric Properties of a Standardized Observation Protocol to Quantify Pediatric Physical Therapy Actions.

    PubMed

    Sonderer, Patrizia; Akhbari Ziegler, Schirin; Gressbach Oertle, Barbara; Meichtry, André; Hadders-Algra, Mijna

    2017-07-01

    Pediatric physical therapy (PPT) is characterized by heterogeneity. This blurs the evaluation of effective components of PPT. The Groningen Observation Protocol (GOP) was developed to quantify contents of PPT. This study assesses the reliability and completeness of the GOP. Sixty infant PPT sessions were video-taped. Two random samples of 10 videos were used to determine interrater and intrarater reliability using interclass correlation coefficients (ICCs) with 95% confidence intervals. Completeness of GOP 2.0 was based on 60 videos. Interrater reliability of quantifying PPT actions was excellent (ICC, 0.75-1.0) in 71% and sufficient to good (ICC, 0.4-0.74) in 24% of PPT actions. Intrarater reliability was excellent in 94% and sufficient to good in 6% of PPT actions. Completeness was good for greater than 90% of PPT actions. GOP 2.0 has good reliability and completeness. After appropriate training, it is a useful tool to quantify PPT for children with developmental disorders.

  17. Electrical impedance myography in facioscapulohumeral muscular dystrophy.

    PubMed

    Statland, Jeffrey M; Heatwole, Chad; Eichinger, Katy; Dilek, Nuran; Martens, William B; Tawil, Rabi

    2016-10-01

    In this study we determined the reliability and validity of electrical impedance myography (EIM) in facioscapulohumeral muscular dystrophy (FSHD). We performed a prospective study of EIM on 16 bilateral limb and trunk muscles in 35 genetically defined and clinically affected FSHD patients (reliability testing on 18 patients). Summary scores based on body region were derived. Reactance and phase (50 and 100 kHz) were compared with measures of strength, FSHD disease severity, and functional outcomes. Participants were mostly men, mean age 53.0 years, and included a full range of severity. Limb and trunk muscles showed good to excellent reliability [intraclass correlation coefficients (ICC) 0.72-0.99]. Summary scores for the arm, leg, and trunk showed excellent reliability (ICC 0.89-0.98). Reactance was the most sensitive EIM parameter to a broad range of FSHD disease metrics. EIM is a reliable measure of muscle composition in FSHD that offers the possibility to serially evaluate affected muscles. Muscle Nerve 54: 696-701, 2016. © 2016 Wiley Periodicals, Inc.

  18. Silicon carbide nanomaterial as a coating for solid-phase microextraction.

    PubMed

    Tian, Yu; Feng, Juanjuan; Wang, Xiuqin; Sun, Min; Luo, Chuannan

    2018-01-26

    Silicon carbide has excellent properties, such as corrosion resistance, high strength, oxidation resistance, high temperature, and so on. Based on these properties, silicon carbide was coated on stainless-steel wire and used as a solid-phase microextraction coating, and polycyclic aromatic hydrocarbons were employed as model analytes. Using gas chromatography, some important factors that affect the extraction efficiency were optimized one by one, and an analytical method was established. The analytical method showed wide linear ranges (0.1-30, 0.03-30, and 0.01-30 μg/L) with satisfactory correlation coefficients (0.9922-0.9966) and low detection limits (0.003-0.03 μg/L). To investigate the practical application of the method, rainwater and cigarette ash aqueous solution were collected as real samples for extraction and detection. The results indicate that silicon carbide has excellent application in the field of solid-phase microextraction. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Reliability and validity of Arabic translation of Medication Adherence Report Scale (MARS) and Beliefs about Medication Questionnaire (BMQ)–specific for use in children and their parents

    PubMed Central

    Alsous, Mervat; Alhalaiqa, Fadwa; Abu Farha, Rana; Abdel Jalil, Mariam; McElnay, James; Horne, Robert

    2017-01-01

    Objectives to evaluate the reliability and discriminant validity of Arabic translation of the Medication Adherence Report Scale (MARS) and the Beliefs about Medication Questionnaire-specific (BMQ-specific). Methods Having developed Arabic translations of the study instruments, a cross-sectional study was carried out between March and October 2015 in two multidisciplinary governmental hospitals in Jordan. An expert panel monitored the forward and backward translation of the MARS and BMQ. Standard Arabic was used (with no specific dialect inclusion) to allow greater generalisability across Arabic speaking countries. Once the Arabic translations of the questionnaires were developed they were tested for consistency, validity and reliability on a group of children with chronic diseases and their parents. Results A total of 258 parents and 208 children were included in the study. The median age of participated children and parents was 15 years and 42 years respectively. Principle component analysis of all questionnaires indicated that all had good construct validity as they clearly measured one construct. The questionnaires were deemed reliable based on the results of Cronbach alpha coefficient. Furthermore, reliability of the questionnaires was demonstrated by test-retest intraclass correlation coefficients (ICC) which ranged from good to excellent for all scales (ICC>0.706). The Pearson correlation coefficient ranged from 0.546–0.805 for the entire sample which indicated a significant moderate to strong positive correlation between MARS and BMQ items at time 1 and 2. Reported adherence was greater than 59% using MARS-children and MARS-parents scales, and was correlated with beliefs in necessity and independent of the concerns regarding medications. Conclusion The Arabic translations of both BMQ and MARS for use in children and their parents have good internal consistency and proved to be valid and reliable tools that can be used by researchers in clinical practice to measure adherence and beliefs about medications in Arabic speaking patient populations. PMID:28192467

  20. Reliability and validity of Arabic translation of Medication Adherence Report Scale (MARS) and Beliefs about Medication Questionnaire (BMQ)-specific for use in children and their parents.

    PubMed

    Alsous, Mervat; Alhalaiqa, Fadwa; Abu Farha, Rana; Abdel Jalil, Mariam; McElnay, James; Horne, Robert

    2017-01-01

    to evaluate the reliability and discriminant validity of Arabic translation of the Medication Adherence Report Scale (MARS) and the Beliefs about Medication Questionnaire-specific (BMQ-specific). Having developed Arabic translations of the study instruments, a cross-sectional study was carried out between March and October 2015 in two multidisciplinary governmental hospitals in Jordan. An expert panel monitored the forward and backward translation of the MARS and BMQ. Standard Arabic was used (with no specific dialect inclusion) to allow greater generalisability across Arabic speaking countries. Once the Arabic translations of the questionnaires were developed they were tested for consistency, validity and reliability on a group of children with chronic diseases and their parents. A total of 258 parents and 208 children were included in the study. The median age of participated children and parents was 15 years and 42 years respectively. Principle component analysis of all questionnaires indicated that all had good construct validity as they clearly measured one construct. The questionnaires were deemed reliable based on the results of Cronbach alpha coefficient. Furthermore, reliability of the questionnaires was demonstrated by test-retest intraclass correlation coefficients (ICC) which ranged from good to excellent for all scales (ICC>0.706). The Pearson correlation coefficient ranged from 0.546-0.805 for the entire sample which indicated a significant moderate to strong positive correlation between MARS and BMQ items at time 1 and 2. Reported adherence was greater than 59% using MARS-children and MARS-parents scales, and was correlated with beliefs in necessity and independent of the concerns regarding medications. The Arabic translations of both BMQ and MARS for use in children and their parents have good internal consistency and proved to be valid and reliable tools that can be used by researchers in clinical practice to measure adherence and beliefs about medications in Arabic speaking patient populations.

  1. A new approach to the measurement of pelvic asymmetry: proposed methods and reliability.

    PubMed

    Gnat, Rafael; Biały, Maciej

    2015-05-01

    This is a methodological study presenting a novel method of pelvic asymmetry (PA) measurement for use in the research laboratory setting. The purpose of the study is (1) to establish intrarater and interrater reliability of the proposed measures of PA, (2) to verify the influence of repeated measurements on the reliability, and (3) to assess correlation between the proposed measures of PA. Twelve healthy volunteers participated, and 2 teams of raters were involved. Registration of anatomic landmarks' positions in the optical motion capture system was repeated 3 times. Two asymmetry indexes were calculated: for pelvic torsion and for lateral pelvic tilt. Interclass correlation coefficients (ICCs), standard errors of measurement, and smallest detectable differences were used to describe the intrarater and interrater reliability of the 2 indexes. After 2 repeated registrations of pelvic landmarks' positions, the reliability of our asymmetry indexes was good and excellent. The ICCs for intrarater reliability ranged from 0.96 to 0.97; the ICCs for interrater reliability ranged 0.81 to 0.90. There was moderate, nonsignificant correlation between asymmetry indexes for pelvis torsion and for lateral pelvic tilt (r = 0.45, P = .14). The 2 proposed asymmetry indexes showed good and excellent intrarater and interrater reliability after 2 repeated registrations of pelvic landmarks' positions and thus may be useful in the research laboratory setting. However, these indexes are not strongly correlated, which suggests that the 2 types of PA may constitute different clinical entities. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  2. Genome-scale cluster analysis of replicated microarrays using shrinkage correlation coefficient.

    PubMed

    Yao, Jianchao; Chang, Chunqi; Salmi, Mari L; Hung, Yeung Sam; Loraine, Ann; Roux, Stanley J

    2008-06-18

    Currently, clustering with some form of correlation coefficient as the gene similarity metric has become a popular method for profiling genomic data. The Pearson correlation coefficient and the standard deviation (SD)-weighted correlation coefficient are the two most widely-used correlations as the similarity metrics in clustering microarray data. However, these two correlations are not optimal for analyzing replicated microarray data generated by most laboratories. An effective correlation coefficient is needed to provide statistically sufficient analysis of replicated microarray data. In this study, we describe a novel correlation coefficient, shrinkage correlation coefficient (SCC), that fully exploits the similarity between the replicated microarray experimental samples. The methodology considers both the number of replicates and the variance within each experimental group in clustering expression data, and provides a robust statistical estimation of the error of replicated microarray data. The value of SCC is revealed by its comparison with two other correlation coefficients that are currently the most widely-used (Pearson correlation coefficient and SD-weighted correlation coefficient) using statistical measures on both synthetic expression data as well as real gene expression data from Saccharomyces cerevisiae. Two leading clustering methods, hierarchical and k-means clustering were applied for the comparison. The comparison indicated that using SCC achieves better clustering performance. Applying SCC-based hierarchical clustering to the replicated microarray data obtained from germinating spores of the fern Ceratopteris richardii, we discovered two clusters of genes with shared expression patterns during spore germination. Functional analysis suggested that some of the genetic mechanisms that control germination in such diverse plant lineages as mosses and angiosperms are also conserved among ferns. This study shows that SCC is an alternative to the Pearson correlation coefficient and the SD-weighted correlation coefficient, and is particularly useful for clustering replicated microarray data. This computational approach should be generally useful for proteomic data or other high-throughput analysis methodology.

  3. Tests of Hypotheses Arising In the Correlated Random Coefficient Model*

    PubMed Central

    Heckman, James J.; Schmierer, Daniel

    2010-01-01

    This paper examines the correlated random coefficient model. It extends the analysis of Swamy (1971), who pioneered the uncorrelated random coefficient model in economics. We develop the properties of the correlated random coefficient model and derive a new representation of the variance of the instrumental variable estimator for that model. We develop tests of the validity of the correlated random coefficient model against the null hypothesis of the uncorrelated random coefficient model. PMID:21170148

  4. [Evaluating training programs on occupational health and safety: questionnaire development].

    PubMed

    Zhou, Xiao-Yan; Wang, Zhi-Ming; Wang, Mian-Zhen

    2006-03-01

    To develop a questionnaire to evaluate the quality of training programs on occupational health and safety. A questionnaire comprising five subscales and 21 items was developed. The reliability and validity of the questionnaire was tested. Final validation of the questionnaire was undertaken in 700 workers in an oil refining company. The Cronbach's alpha coefficients of the five subscales ranged from 0.6194 to 0.6611. The subscale-scale Pearson correlation coefficients ranged from 0.568 to 0.834 . The theta coefficients of the five subscales were greater than 0.7. The factor loadings of the five subscales in the principal component analysis ranged from 0.731 to 0.855. Use of the questionnaire in the 700 workers produced a good discriminability, with excellent, good, fair and poor comprising 22.2%, 31.2%, 32.4% and 14.1 respectively. Given the fact that 18.7% of workers had never been trained and 29.7% of workers got one-off training only, the training program scored an average of 57.2. The questionnaire is suitable to be used in evaluating the quality of training programs on occupational health and safety. The oil refining company needs to improve training for their workers on occupational health and safety.

  5. Repeatability of two-dimensional chemical shift imaging multivoxel proton magnetic resonance spectroscopy for measuring human cerebral choline-containing compounds.

    PubMed

    Puri, Basant K; Egan, Mary; Wallis, Fintan; Jakeman, Philip

    2018-03-22

    To investigate the repeatability of proton magnetic resonance spectroscopy in the in vivo measurement of human cerebral levels of choline-containing compounds (Cho). Two consecutive scans were carried out in six healthy resting subjects at a magnetic field strength of 1.5 T. On each occasion, neurospectroscopy data were collected from 64 voxels using the same 2D chemical shift imaging (CSI) sequence. The data were analyzed in the same way, using the same software, to obtain the values for each voxel of the ratio of Cho to creatine. The Wilcoxon related-samples signed-rank test, coefficient of variation (CV), repeatability coefficient (RC), and intraclass correlation coefficient (ICC) were used to assess the repeatability. The CV ranged from 2.75% to 33.99%, while the minimum RC was 5.68%. There was excellent reproducibility, as judged by significant ICC values, in 26 voxels. Just three voxels showed significant differences according to the Wilcoxon related-samples signed-rank test. It is therefore concluded that when CSI multivoxel proton neurospectroscopy is used to measure cerebral choline-containing compounds at 1.5 T, the reproducibility is highly acceptable.

  6. Effect of knee angle on neuromuscular assessment of plantar flexor muscles: A reliability study

    PubMed Central

    Cornu, Christophe; Jubeau, Marc

    2018-01-01

    Introduction This study aimed to determine the intra- and inter-session reliability of neuromuscular assessment of plantar flexor (PF) muscles at three knee angles. Methods Twelve young adults were tested for three knee angles (90°, 30° and 0°) and at three time points separated by 1 hour (intra-session) and 7 days (inter-session). Electrical (H reflex, M wave) and mechanical (evoked and maximal voluntary torque, activation level) parameters were measured on the PF muscles. Intraclass correlation coefficients (ICC) and coefficients of variation were calculated to determine intra- and inter-session reliability. Results The mechanical measurements presented excellent (ICC>0.75) intra- and inter-session reliabilities regardless of the knee angle considered. The reliability of electrical measurements was better for the 90° knee angle compared to the 0° and 30° angles. Conclusions Changes in the knee angle may influence the reliability of neuromuscular assessments, which indicates the importance of considering the knee angle to collect consistent outcomes on the PF muscles. PMID:29596480

  7. Determination of heat capacity of ionic liquid based nanofluids using group method of data handling technique

    NASA Astrophysics Data System (ADS)

    Sadi, Maryam

    2018-01-01

    In this study a group method of data handling model has been successfully developed to predict heat capacity of ionic liquid based nanofluids by considering reduced temperature, acentric factor and molecular weight of ionic liquids, and nanoparticle concentration as input parameters. In order to accomplish modeling, 528 experimental data points extracted from the literature have been divided into training and testing subsets. The training set has been used to predict model coefficients and the testing set has been applied for model validation. The ability and accuracy of developed model, has been evaluated by comparison of model predictions with experimental values using different statistical parameters such as coefficient of determination, mean square error and mean absolute percentage error. The mean absolute percentage error of developed model for training and testing sets are 1.38% and 1.66%, respectively, which indicate excellent agreement between model predictions and experimental data. Also, the results estimated by the developed GMDH model exhibit a higher accuracy when compared to the available theoretical correlations.

  8. Measurement Properties of the Brief Michigan Hand Outcomes Questionnaire in Patients With Dupuytren Contracture.

    PubMed

    Wehrli, Martina; Hensler, Stefanie; Schindele, Stephan; Herren, Daniel B; Marks, Miriam

    2016-09-01

    The brief Michigan Hand Outcomes Questionnaire (briefMHQ) was developed as a shorter version of the Michigan Hand Outcomes Questionnaire (MHQ), but its measurement properties have not been investigated in patients with Dupuytren contracture. The objective of the study was to investigate the reliability, validity, responsiveness, and interpretability of the briefMHQ. Fifty-seven patients diagnosed with Dupuytren contracture completed the briefMHQ as well as the full-length MHQ and Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH) questionnaire at baseline. Two to 14 days after baseline and 1 year after collagenase injection or surgery, patients again filled out the briefMHQ. Reliability was determined using the intraclass correlation coefficient and by calculating internal consistency (Cronbach alpha). Validity was tested by quantifying correlations with the full-length MHQ and QuickDASH. Responsiveness, based on the standardized response mean and the minimally clinically important change, was also determined. The briefMHQ had an intraclass correlation coefficient of 0.87, Cronbach alpha of 0.88, and correlations of r = 0.88 and -0.82 with the original MHQ and QuickDASH, respectively. The standardized response mean was 0.9 and the minimally clinically important change was 7 points. Overall, the briefMHQ demonstrates excellent reliability, good validity, and high responsiveness in patients with Dupuytren contracture. The briefMHQ is an accurate and time-saving tool to evaluate patients with Dupuytren contracture and the effect of a corresponding treatment. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  9. Biomechanical factors associated with time to complete a change of direction cutting maneuver.

    PubMed

    Marshall, Brendan M; Franklyn-Miller, Andrew D; King, Enda A; Moran, Kieran A; Strike, Siobhán C; Falvey, Éanna C

    2014-10-01

    Cutting ability is an important aspect of many team sports, however, the biomechanical determinants of cutting performance are not well understood. This study aimed to address this issue by identifying the kinetic and kinematic factors correlated with the time to complete a cutting maneuver. In addition, an analysis of the test-retest reliability of all biomechanical measures was performed. Fifteen (n = 15) elite multidirectional sports players (Gaelic hurling) were recruited, and a 3-dimensional motion capture analysis of a 75° cut was undertaken. The factors associated with cutting time were determined using bivariate Pearson's correlations. Intraclass correlation coefficients (ICCs) were used to examine the test-retest reliability of biomechanical measures. Five biomechanical factors were associated with cutting time (2.28 ± 0.11 seconds): peak ankle power (r = 0.77), peak ankle plantar flexor moment (r = 0.65), range of pelvis lateral tilt (r = -0.54), maximum thorax lateral rotation angle (r = 0.51), and total ground contact time (r = -0.48). Intraclass correlation coefficient scores for these 5 factors, and indeed for the majority of the other biomechanical measures, ranged from good to excellent (ICC >0.60). Explosive force production about the ankle, pelvic control during single-limb support, and torso rotation toward the desired direction of travel were all key factors associated with cutting time. These findings should assist in the development of more effective training programs aimed at improving similar cutting performances. In addition, test-retest reliability scores were generally strong, therefore, motion capture techniques seem well placed to further investigate the determinants of cutting ability.

  10. CROSS-CULTURAL ADAPTATION AND VALIDATION OF THE ITCHING SEVERITY SCALE IN CHILDREN AND ADOLESCENTS WITH ATOPIC DERMATITIS

    PubMed Central

    Bruscky, Dayanne Mota Veloso; Melo, Ana Caroline Cavalcanti Dela Bianca; Sarinho, Emanuel Sávio Cavalcanti

    2017-01-01

    ABSTRACT Objective: To translate, adapt and validate the Itch Severity Scale to a Brazilian version (ISS-Ped) in order to measure the severity of pruritus in children and adolescents with atopic dermatitis. Methods: This is a methodological study of validation of an instrument following recommended protocols. The translated version was evaluated by a group of experts including one professional with experience in instrument validation, three English teachers, one linguistics teacher and seven allergists. After this, the scale was applied to 42 parents of children aged between 2 and 18 years old with atopic dermatitis, and 42 parents of children without pruritic diseases. Results were evaluated according to the severity of atopic dermatitis and disease control, and they were compared between groups with and without atopic dermatitis. Results: More than 90% of the questions were clear to the parents. The ISS-Ped showed a strong positive correlation with the severity of atopic dermatitis (Pearson: 0.74; p<0.001) and a good correlation with the control of dermatitis (point-biserial correlation coefficient: 0.65; p<0.001). The scale showed excellent internal consistency (Cronbach’s α: 0.96) and adequate test and retest agreement (95% confidence interval of intraclass correlation coefficient: 0.89-0.99; p<0.001). Conclusions: The ISS-Ped is a feasible, valid, reliable and satisfactorily equivalent. The translated scale was appropriate to assess the severity of itching in children and adolescents with eczema, allowing comparisons in the clinical practice and in the research setting. PMID:28977301

  11. Analysis of spectra using correlation functions

    NASA Technical Reports Server (NTRS)

    Beer, Reinhard; Norton, Robert H.

    1988-01-01

    A novel method is presented for the quantitative analysis of spectra based on the properties of the cross correlation between a real spectrum and either a numerical synthesis or laboratory simulation. A new goodness-of-fit criterion called the heteromorphic coefficient H is proposed that has the property of being zero when a fit is achieved and varying smoothly through zero as the iteration proceeds, providing a powerful tool for automatic or near-automatic analysis. It is also shown that H can be rendered substantially noise-immune, permitting the analysis of very weak spectra well below the apparent noise level and, as a byproduct, providing Doppler shift and radial velocity information with excellent precision. The technique is in regular use in the Atmospheric Trace Molecule Spectroscopy (ATMOS) project and operates in an interactive, realtime computing environment with turn-around times of a few seconds or less.

  12. Determination of Time since Death using Vitreous Humor Tryptophan.

    PubMed

    Ansari, Niha; Menon, Shobhana K

    2017-09-01

    Determination of time since death (TSD) plays very important role in forensic examination as it narrows down field of suspects and aids in deceased identification. This study utilizes the fluorescence property of vitreous humor (VH) tryptophan to determine TSD using o-phthalaldehyde (OPA). The detection limit of these fluorometric studies was found to be 8 ppb indicating sensitivity and high accuracy in TSD determination. The study was performed on selected 76 cadaver with known TSD ranging from 3 to 90 h. Excellent correlation between VH tryptophan and TSD was obtained with a coefficient of correlation R 2 = 0.9590. Results showed statistically significant increase in vitreous tryptophan with TSD up to 90 h, and the proposed method was efficaciously applied for prediction of TSD as no systematic error exist. The regression equation obtained from the study is [Trp] = 2.21 + 2.98 * TSD. © 2017 American Academy of Forensic Sciences.

  13. Modified Regression Correlation Coefficient for Poisson Regression Model

    NASA Astrophysics Data System (ADS)

    Kaengthong, Nattacha; Domthong, Uthumporn

    2017-09-01

    This study gives attention to indicators in predictive power of the Generalized Linear Model (GLM) which are widely used; however, often having some restrictions. We are interested in regression correlation coefficient for a Poisson regression model. This is a measure of predictive power, and defined by the relationship between the dependent variable (Y) and the expected value of the dependent variable given the independent variables [E(Y|X)] for the Poisson regression model. The dependent variable is distributed as Poisson. The purpose of this research was modifying regression correlation coefficient for Poisson regression model. We also compare the proposed modified regression correlation coefficient with the traditional regression correlation coefficient in the case of two or more independent variables, and having multicollinearity in independent variables. The result shows that the proposed regression correlation coefficient is better than the traditional regression correlation coefficient based on Bias and the Root Mean Square Error (RMSE).

  14. Distance correlation methods for discovering associations in large astrophysical databases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martínez-Gómez, Elizabeth; Richards, Mercedes T.; Richards, Donald St. P., E-mail: elizabeth.martinez@itam.mx, E-mail: mrichards@astro.psu.edu, E-mail: richards@stat.psu.edu

    2014-01-20

    High-dimensional, large-sample astrophysical databases of galaxy clusters, such as the Chandra Deep Field South COMBO-17 database, provide measurements on many variables for thousands of galaxies and a range of redshifts. Current understanding of galaxy formation and evolution rests sensitively on relationships between different astrophysical variables; hence an ability to detect and verify associations or correlations between variables is important in astrophysical research. In this paper, we apply a recently defined statistical measure called the distance correlation coefficient, which can be used to identify new associations and correlations between astrophysical variables. The distance correlation coefficient applies to variables of any dimension,more » can be used to determine smaller sets of variables that provide equivalent astrophysical information, is zero only when variables are independent, and is capable of detecting nonlinear associations that are undetectable by the classical Pearson correlation coefficient. Hence, the distance correlation coefficient provides more information than the Pearson coefficient. We analyze numerous pairs of variables in the COMBO-17 database with the distance correlation method and with the maximal information coefficient. We show that the Pearson coefficient can be estimated with higher accuracy from the corresponding distance correlation coefficient than from the maximal information coefficient. For given values of the Pearson coefficient, the distance correlation method has a greater ability than the maximal information coefficient to resolve astrophysical data into highly concentrated horseshoe- or V-shapes, which enhances classification and pattern identification. These results are observed over a range of redshifts beyond the local universe and for galaxies from elliptical to spiral.« less

  15. Clustering Coefficients for Correlation Networks.

    PubMed

    Masuda, Naoki; Sakaki, Michiko; Ezaki, Takahiro; Watanabe, Takamitsu

    2018-01-01

    Graph theory is a useful tool for deciphering structural and functional networks of the brain on various spatial and temporal scales. The clustering coefficient quantifies the abundance of connected triangles in a network and is a major descriptive statistics of networks. For example, it finds an application in the assessment of small-worldness of brain networks, which is affected by attentional and cognitive conditions, age, psychiatric disorders and so forth. However, it remains unclear how the clustering coefficient should be measured in a correlation-based network, which is among major representations of brain networks. In the present article, we propose clustering coefficients tailored to correlation matrices. The key idea is to use three-way partial correlation or partial mutual information to measure the strength of the association between the two neighboring nodes of a focal node relative to the amount of pseudo-correlation expected from indirect paths between the nodes. Our method avoids the difficulties of previous applications of clustering coefficient (and other) measures in defining correlational networks, i.e., thresholding on the correlation value, discarding of negative correlation values, the pseudo-correlation problem and full partial correlation matrices whose estimation is computationally difficult. For proof of concept, we apply the proposed clustering coefficient measures to functional magnetic resonance imaging data obtained from healthy participants of various ages and compare them with conventional clustering coefficients. We show that the clustering coefficients decline with the age. The proposed clustering coefficients are more strongly correlated with age than the conventional ones are. We also show that the local variants of the proposed clustering coefficients (i.e., abundance of triangles around a focal node) are useful in characterizing individual nodes. In contrast, the conventional local clustering coefficients were strongly correlated with and therefore may be confounded by the node's connectivity. The proposed methods are expected to help us to understand clustering and lack thereof in correlational brain networks, such as those derived from functional time series and across-participant correlation in neuroanatomical properties.

  16. Clustering Coefficients for Correlation Networks

    PubMed Central

    Masuda, Naoki; Sakaki, Michiko; Ezaki, Takahiro; Watanabe, Takamitsu

    2018-01-01

    Graph theory is a useful tool for deciphering structural and functional networks of the brain on various spatial and temporal scales. The clustering coefficient quantifies the abundance of connected triangles in a network and is a major descriptive statistics of networks. For example, it finds an application in the assessment of small-worldness of brain networks, which is affected by attentional and cognitive conditions, age, psychiatric disorders and so forth. However, it remains unclear how the clustering coefficient should be measured in a correlation-based network, which is among major representations of brain networks. In the present article, we propose clustering coefficients tailored to correlation matrices. The key idea is to use three-way partial correlation or partial mutual information to measure the strength of the association between the two neighboring nodes of a focal node relative to the amount of pseudo-correlation expected from indirect paths between the nodes. Our method avoids the difficulties of previous applications of clustering coefficient (and other) measures in defining correlational networks, i.e., thresholding on the correlation value, discarding of negative correlation values, the pseudo-correlation problem and full partial correlation matrices whose estimation is computationally difficult. For proof of concept, we apply the proposed clustering coefficient measures to functional magnetic resonance imaging data obtained from healthy participants of various ages and compare them with conventional clustering coefficients. We show that the clustering coefficients decline with the age. The proposed clustering coefficients are more strongly correlated with age than the conventional ones are. We also show that the local variants of the proposed clustering coefficients (i.e., abundance of triangles around a focal node) are useful in characterizing individual nodes. In contrast, the conventional local clustering coefficients were strongly correlated with and therefore may be confounded by the node's connectivity. The proposed methods are expected to help us to understand clustering and lack thereof in correlational brain networks, such as those derived from functional time series and across-participant correlation in neuroanatomical properties. PMID:29599714

  17. [Correlation coefficient-based classification method of hydrological dependence variability: With auto-regression model as example].

    PubMed

    Zhao, Yu Xi; Xie, Ping; Sang, Yan Fang; Wu, Zi Yi

    2018-04-01

    Hydrological process evaluation is temporal dependent. Hydrological time series including dependence components do not meet the data consistency assumption for hydrological computation. Both of those factors cause great difficulty for water researches. Given the existence of hydrological dependence variability, we proposed a correlationcoefficient-based method for significance evaluation of hydrological dependence based on auto-regression model. By calculating the correlation coefficient between the original series and its dependence component and selecting reasonable thresholds of correlation coefficient, this method divided significance degree of dependence into no variability, weak variability, mid variability, strong variability, and drastic variability. By deducing the relationship between correlation coefficient and auto-correlation coefficient in each order of series, we found that the correlation coefficient was mainly determined by the magnitude of auto-correlation coefficient from the 1 order to p order, which clarified the theoretical basis of this method. With the first-order and second-order auto-regression models as examples, the reasonability of the deduced formula was verified through Monte-Carlo experiments to classify the relationship between correlation coefficient and auto-correlation coefficient. This method was used to analyze three observed hydrological time series. The results indicated the coexistence of stochastic and dependence characteristics in hydrological process.

  18. Validity and Reliability of a Portable Balance Tracking System, BTrackS, in Older Adults.

    PubMed

    Levy, Susan S; Thralls, Katie J; Kviatkovsky, Shiloah A

    Falls are the leading cause of disability, injury, hospital admission, and injury-related death among older adults. Balance limitations have consistently been identified as predictors of falls and increased fall risk. Field measures of balance are limited by issues of subjectivity, ceiling effects, and low sensitivity to change. The gold standard for measuring balance is the force plate; however, its field use is untenable due to high cost and lack of portability. Thus, a critical need is observed for valid objective field measures of balance to accurately assess balance and identify limitations over time. The purpose of this study was to examine the concurrent validity and 3-day test-retest reliability of Balance Tracking System (BTrackS) in community-dwelling older adults. Minimal detectable change values were also calculated to reflect changes in balance beyond measurement error. Postural sway data were collected from community-dwelling older adults (N = 49, mean [SD] age = 71.3 [7.3] years) with a force plate and BTrackS in multitrial eyes open (EO) and eyes closed (EC) static balance conditions. Force sensors transmitted BTrackS data via a USB to a computer running custom software. Three approaches to concurrent validity were taken including calculation of Pearson product moment correlation coefficients, repeated-measures ANOVAs, and Bland-Altman plots. Three-day test-retest reliability of BTrackS was examined in a second sample of 47 community-dwelling older adults (mean [SD] age = 75.8 [7.7] years) using intraclass correlation coefficients and MDC values at 95% CI (MDC95) were calculated. BTrackS demonstrated good validity using Pearson product moment correlations (r > 0.90). Repeated-measures ANOVA and Bland-Altman plots indicated some BTrackS bias with center of pressure (COP) values higher than FP COP values in the EO (mean [SD] bias = 4.0 [6.8]) and EC (mean [SD] bias = 9.6 [12.3]) conditions. Test-retest reliability using intraclass correlation coefficients (ICC2.1 was excellent (0.83) and calculated MDC95 for EO (9.6 cm) and EC (19.4 cm) and suggested that postural sway changes of these amounts are meaningful. BTrackS showed some bias with values exceeding force plate values in both EO and EC conditions. Excellent test-retest reliability and resulting MDC95 values indicated that BTrackS has the potential to identify meaningful changes in balance that may warrant intervention. BTrackS is an objective measure of balance that can be used to monitor balance in community-dwelling older adults over time. It can reliably identify changes that may require further attention (eg, fall-prevention strategies, declines in physical function) and shows promise for assessing intervention efficacy in this growing segment of the population.

  19. Simplified Chinese version of the Forgotten Joint Score (FJS) for patients who underwent joint arthroplasty: cross-cultural adaptation and validation.

    PubMed

    Cao, Shiqi; Liu, Ning; Han, Wuxiang; Zi, Yunpeng; Peng, Fan; Li, Lexiang; Fu, Qiwei; Chen, Yi; Zheng, Weijie; Qian, Qirong

    2017-01-14

    The Forgotten Joint Score (FJS) is a newly developed health-related quality of life (HRQoL) questionnaire designed to evaluate the awareness after total knee arthroplasty (TKA). This study cross-culturally adapted and psychometrically validated a simplified Chinese version of the FJS (SC-FJS). Cross-cultural adaptation was performed according to the internationally recognized guidelines. One-hundred and fifty participants who underwent primary TKA were recruited in this study. Cronbach's α and intra-class correlations were used to determine reliability. Construct validity was analyzed by evaluating the correlations between SC-FJS and the Knee Injury and Osteoarthritis Outcome Score (KOOS) and the short form (36) health survey (SF-36). Each of the 12 items was properly responded and correlated with the total items. SC-FJS had excellent reliability [Cronbach's α = 0.907, intra-class correlation coefficient (ICC) = 0.970, 95% CI 0.959-0.978). Elimination of any one item in all did not result in a value of Cronbach's α of <0.80. SC-FJS had a high correlation with symptoms (0.67, p < 0.001) and pain (0.60, p < 0.001) domains of KOOS and social functioning (0.66, p < 0.001) domain of SF-36, and it also moderately correlated with function in daily living (0.53, p < 0.001) and function in sport and recreation (0.40, p < 0.001) domains of KOOS, and physical subscale of SF-36 (0.49-0.53, p < 0.001) but had a low (r = 0.20) or not significant (p > 0.05) correlation with mental subscale of SF-36. SC-FJS demonstrated excellent acceptability, internal consistency, reliability, and construct validity, which can be recommended for patients who underwent joint arthroplasty in Mainland China.

  20. Assessment of the accuracy of a new tool for the screening of smartphone addiction

    PubMed Central

    2017-01-01

    Objective To translate, adapt and validate the Smartphone Addiction Inventory (SPAI) in a Brazilian population of young adults. Method We employed the translation and back-translation method for the adaptation of the Brazilian version SPAI (SPAI-BR). The sample consisted of 415 university students. Data was collected through an electronic questionnaire, which consisted of the SPAI-BR and the Goodman Criteria (gold standard). The retests were carried out 10–15 days after the initial tests with 130 individuals. Results The SPAI-BR maintained semantic, idiomatic and conceptual equivalences from the original scale. The Confirmatory Factor Analysis confirmed the One-factor model of the SPAI with good fit indexes (x2 = 767.861, CFI = 0.913, TLI = 0.905, RMSE = 0.061, WRMR = 1.465). The Kuder-Richardson Coefficient showed good internal consistency. The analysis of the ROC curve established an area under the curve of 86.38%. The Intraclass-Correlation Coefficient of 0.926 between the test and the retest demonstrated an excellent temporal stability. The high correlation between SPAI-BR and the Goodman Criteria (rs = 0.750) established the convergent validity. Conclusion The SPAI-BR is a valid and reliable tool for the detection of Smartphone Addiction in Brazilian university students. PMID:28520798

  1. Depth-time interpolation of feature trends extracted from mobile microelectrode data with kernel functions.

    PubMed

    Wong, Stephen; Hargreaves, Eric L; Baltuch, Gordon H; Jaggi, Jurg L; Danish, Shabbar F

    2012-01-01

    Microelectrode recording (MER) is necessary for precision localization of target structures such as the subthalamic nucleus during deep brain stimulation (DBS) surgery. Attempts to automate this process have produced quantitative temporal trends (feature activity vs. time) extracted from mobile MER data. Our goal was to evaluate computational methods of generating spatial profiles (feature activity vs. depth) from temporal trends that would decouple automated MER localization from the clinical procedure and enhance functional localization in DBS surgery. We evaluated two methods of interpolation (standard vs. kernel) that generated spatial profiles from temporal trends. We compared interpolated spatial profiles to true spatial profiles that were calculated with depth windows, using correlation coefficient analysis. Excellent approximation of true spatial profiles is achieved by interpolation. Kernel-interpolated spatial profiles produced superior correlation coefficient values at optimal kernel widths (r = 0.932-0.940) compared to standard interpolation (r = 0.891). The choice of kernel function and kernel width resulted in trade-offs in smoothing and resolution. Interpolation of feature activity to create spatial profiles from temporal trends is accurate and can standardize and facilitate MER functional localization of subcortical structures. The methods are computationally efficient, enhancing localization without imposing additional constraints on the MER clinical procedure during DBS surgery. Copyright © 2012 S. Karger AG, Basel.

  2. Wii Balance Board: Reliability and Clinical Use in Assessment of Balance in Healthy Elderly Women.

    PubMed

    Monteiro-Junior, Renato Sobral; Ferreira, Arthur Sá; Puell, Vivian Neiva; Lattari, Eduardo; Machado, Sérgio; Otero Vaghetti, César Augusto; da Silva, Elirez Bezerra

    2015-01-01

    Force plate is considered gold standard tool to assess body balance. However the Wii Balance Board (WBB) platform is a trustworthy equipment to assess stabilometric components in young people. Thus, we aim to examine the reliability of measures of center of pressure with WBB in healthy elderly women. Twenty one healthy and physically active women were enrolled in the study (age: 64 ± 7 years; body mass index: 29 ± 5 kg/m2. The WBB was used to assess the center of pressure measures in the individuals. Pressure was linearly applied to different points to test the platform precision. Three assessments were performed, with two of them being held on the same day at a 5- to 10-minute interval, and the third one was performed 48 h later. A linear regression analysis was used to find out linearity, while the intraclass correlation coefficient was used to assess reliability. The platform precision was adequate (R2 = 0.997, P = 0.01). Center of pressure measures showed an excellent reliability (all intraclass correlation coefficient values were > 0.90; p < 0.01). The WBB is a precise and reliable tool of body stability quantitative measure in healthy active elderly women and its use should be encouraged in clinical settings.

  3. Psychometric properties of the Malay Version of the hospital anxiety and depression scale: a study of husbands of breast cancer patients in Kuala Lumpur, Malaysia.

    PubMed

    Yusoff, Nasir; Low, Wah Yun; Yip, Cheng-Har

    2011-01-01

    The main objective of this paper is to examine the psychometric properties of the Malay Version of the Hospital Anxiety and Depression Scale (HADS), tested on 67 husbands of the women who were diagnosed with breast cancer. The eligible husbands were retrieved from the Clinical Oncology Clinic at three hospitals in Kuala Lumpur, Malaysia. Data was collected at three weeks and ten weeks following surgery for breast cancer of their wives. The psychometric properties of the HADS were reported based on Cronbach' alpha, Intraclass Correlation Coefficients (ICC), Effect Size Index (ESI), sensitivity and discriminity of the scale. Internal consistency of the scale is excellent, with Cronbach's alpha of 0.88 for Anxiety subscale and 0.79 for Depression subscale. Test-retest Intraclass Correlation Coefficient (ICC) is 0.35 and 0.42 for Anxiety and Depression Subscale, respectively. Small mean differences were observed at test-retest measurement with ESI of 0.21 for Anxiety and 0.19 for Depression. Non-significant result was revealed for the discriminant validity (mastectomy vs lumpectomy). The Malay Version of the HADS is appropriate to measure the anxiety and depression among the husbands of the women with breast cancer in Malaysia.

  4. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.

    PubMed

    Koo, Terry K; Li, Mae Y

    2016-06-01

    Intraclass correlation coefficient (ICC) is a widely used reliability index in test-retest, intrarater, and interrater reliability analyses. This article introduces the basic concept of ICC in the content of reliability analysis. There are 10 forms of ICCs. Because each form involves distinct assumptions in their calculation and will lead to different interpretations, researchers should explicitly specify the ICC form they used in their calculation. A thorough review of the research design is needed in selecting the appropriate form of ICC to evaluate reliability. The best practice of reporting ICC should include software information, "model," "type," and "definition" selections. When coming across an article that includes ICC, readers should first check whether information about the ICC form has been reported and if an appropriate ICC form was used. Based on the 95% confident interval of the ICC estimate, values less than 0.5, between 0.5 and 0.75, between 0.75 and 0.9, and greater than 0.90 are indicative of poor, moderate, good, and excellent reliability, respectively. This article provides a practical guideline for clinical researchers to choose the correct form of ICC and suggests the best practice of reporting ICC parameters in scientific publications. This article also gives readers an appreciation for what to look for when coming across ICC while reading an article.

  5. Calibration of diffuse correlation spectroscopy blood flow index with venous-occlusion diffuse optical spectroscopy in skeletal muscle

    PubMed Central

    Li, Zhe; Baker, Wesley B.; Parthasarathy, Ashwin B.; Ko, Tiffany S.; Wang, Detian; Schenkel, Steven; Durduran, Turgut; Li, Gang; Yodh, Arjun G.

    2015-01-01

    Abstract. We investigate and assess the utility of a simple scheme for continuous absolute blood flow monitoring based on diffuse correlation spectroscopy (DCS). The scheme calibrates DCS using venous-occlusion diffuse optical spectroscopy (VO-DOS) measurements of arm muscle tissue at a single time-point. A calibration coefficient (γ) for the arm is determined, permitting conversion of DCS blood flow indices to absolute blood flow units, and a study of healthy adults (N=10) is carried out to ascertain the variability of γ. The average DCS calibration coefficient for the right (i.e., dominant) arm was γ=(1.24±0.15)×108 (mL·100  mL−1·min−1)/(cm2/s). However, variability can be significant and is apparent in our site-to-site and day-to-day repeated measurements. The peak hyperemic blood flow overshoot relative to baseline resting flow was also studied following arm-cuff ischemia; excellent agreement between VO-DOS and DCS was found (R2=0.95, slope=0.94±0.07, mean difference=−0.10±0.45). Finally, we show that incorporation of subject-specific absolute optical properties significantly improves blood flow calibration accuracy. PMID:26720870

  6. Portuguese community pharmacists' attitudes to and knowledge of antibiotic misuse: questionnaire development and reliability.

    PubMed

    Roque, Fátima; Soares, Sara; Breitenfeld, Luiza; Gonzalez-Gonzalez, Cristian; Figueiras, Adolfo; Herdeiro, Maria Teresa

    2014-01-01

    To develop and evaluate the reliability of a self-administered questionnaire designed to assess the attitudes and knowledge of community pharmacists in Portugal about microbial resistance and the antibiotic dispensing process. This study was divided into the following three stages: (1) design of the questionnaire, which included a literature review and a qualitative study with focus-group sessions; (2) assessment of face and content validity, using a panel of experts and a pre-test of community pharmacists; and, (3) pilot study and reliability analysis, which included a test-retest study covering fifty practising pharmacists based at community pharmacies in five districts situated in Northern Portugal. Questionnaire reproducibility was quantified using the intraclass correlation coefficient (ICC; 95% confidence interval) computed by means of one-way analysis of variance (ANOVA). Internal consistency was evaluated using Cronbach's alpha. The correlation coefficients were fair to good (ICC>0.4) for all statements (scale-items) regarding knowledge of and attitudes to antibiotic resistance, and ranged from fair to good to excellent for statements about situations in which pharmacists acknowledged that antibiotics were sometimes dispensed without a medical prescription (ICC>0.8). Cronbach's alpha for this section was 0.716. The questionnaire designed in this study is valid and reliable in terms of content validity, face validity and reproducibility.

  7. Estimation of the biserial correlation and its sampling variance for use in meta-analysis.

    PubMed

    Jacobs, Perke; Viechtbauer, Wolfgang

    2017-06-01

    Meta-analyses are often used to synthesize the findings of studies examining the correlational relationship between two continuous variables. When only dichotomous measurements are available for one of the two variables, the biserial correlation coefficient can be used to estimate the product-moment correlation between the two underlying continuous variables. Unlike the point-biserial correlation coefficient, biserial correlation coefficients can therefore be integrated with product-moment correlation coefficients in the same meta-analysis. The present article describes the estimation of the biserial correlation coefficient for meta-analytic purposes and reports simulation results comparing different methods for estimating the coefficient's sampling variance. The findings indicate that commonly employed methods yield inconsistent estimates of the sampling variance across a broad range of research situations. In contrast, consistent estimates can be obtained using two methods that appear to be unknown in the meta-analytic literature. A variance-stabilizing transformation for the biserial correlation coefficient is described that allows for the construction of confidence intervals for individual coefficients with close to nominal coverage probabilities in most of the examined conditions. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  8. The use of ultrasound for postoperative monitoring of cerebral bypass grafts: A technical report.

    PubMed

    Morton, Ryan P; Abecassis, Isaac Joshua; Moore, Anne E; Kelly, Cory M; Levitt, Michael R; Kim, Louis J; Sekhar, Laligam N

    2017-06-01

    Duplex ultrasound and transcranial Doppler are valuable tools for post-operative monitoring of extracranial-intracranial cerebral bypass grafts. Here we describe our technique for the evaluation of both high-flow and low-flow cerebral bypass grafts over a nine year period. 186 bypass grafts were studied daily during the inpatient period between Jan 2005 and Dec 2014 after surgery for various cerebrovascular pathologies. There was a technical success rate of 97%. Duplex ultrasonographic flow measurements had excellent interobserver reliability with an intraclass correlation coefficient (ICC) of 0.89 (p=0.009). Technical nuances are highlighted and a brief discussion of pathology is undertaken. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Estimation of the simple correlation coefficient.

    PubMed

    Shieh, Gwowen

    2010-11-01

    This article investigates some unfamiliar properties of the Pearson product-moment correlation coefficient for the estimation of simple correlation coefficient. Although Pearson's r is biased, except for limited situations, and the minimum variance unbiased estimator has been proposed in the literature, researchers routinely employ the sample correlation coefficient in their practical applications, because of its simplicity and popularity. In order to support such practice, this study examines the mean squared errors of r and several prominent formulas. The results reveal specific situations in which the sample correlation coefficient performs better than the unbiased and nearly unbiased estimators, facilitating recommendation of r as an effect size index for the strength of linear association between two variables. In addition, related issues of estimating the squared simple correlation coefficient are also considered.

  10. Dual mobility hip arthroplasty wear measurement: Experimental accuracy assessment using radiostereometric analysis (RSA).

    PubMed

    Pineau, V; Lebel, B; Gouzy, S; Dutheil, J-J; Vielpeau, C

    2010-10-01

    The use of dual mobility cups is an effective method to prevent dislocations. However, the specific design of these implants can raise the suspicion of increased wear and subsequent periprosthetic osteolysis. Using radiostereometric analysis (RSA), migration of the femoral head inside the cup of a dual mobility implant can be defined to apprehend polyethylene wear rate. The study aimed to establish the precision of RSA measurement of femoral head migration in the cup of a dual mobility implant, and its intra- and interobserver variability. A total hip prosthesis phantom was implanted and placed under weight loading conditions in a simulator. Model-based RSA measurement of implant penetration involved specially machined polyethylene liners with increasing concentric wear (no wear, then 0.25, 0.5 and 0.75mm). Three examiners, blinded to the level of wear, analyzed (10 times) the radiostereometric films of the four liners. There was one experienced, one trained, and one inexperienced examiner. Statistical analysis measured the accuracy, precision, and intra- and interobserver variability by calculating Root Mean Square Error (RMSE), Concordance Correlation Coefficient (CCC), Intra Class correlation Coefficient (ICC), and Bland-Altman plots. Our protocol, that used a simple geometric model rather than the manufacturer's CAD files, showed precision of 0.072mm and accuracy of 0.034mm, comparable with machining tolerances with low variability. Correlation between wear measurement and true value was excellent with a CCC of 0.9772. Intraobserver reproducibility was very good with an ICC of 0.9856, 0.9883 and 0.9842, respectively for examiners 1, 2 and 3. Interobserver reproducibility was excellent with a CCC of 0.9818 between examiners 2 and 1, and 0.9713 between examiners 3 and 1. Quantification of wear is indispensable for the surveillance of dual mobility implants. This in vitro study validates our measurement method. Our results, and comparison with other studies using different measurement technologies (RSA, standard radiographs, Martell method) make model-based RSA the reference method for measuring the wear of total hip prostheses in vivo. Level 3. Prospective diagnostic study. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  11. PET Imaging of D2/3 agonist binding in healthy human subjects with the radiotracer [11C]-N-propyl-nor-apomorphine (NPA): preliminary evaluation and reproducibility studies

    PubMed Central

    Narendran, Rajesh; Frankle, W. Gordon; Mason, N. Scott; Laymon, Charles M.; Lopresti, Brian J; Price, Julie C.; Kendro, Steve; Vora, Shivangi; Litschge, Maralee; Mountz, James M.; Mathis, Chester A.

    2009-01-01

    Objective (-)-N-[11C]-Propyl-norapomorphine (NPA) is a full dopamine D2/3 receptor agonist radiotracer suitable for imaging D2/3 receptors configured in a state of high affinity for agonists using Positron Emission Tomography (PET). The aim of the present study was to define the optimal analytic method to derive accurate and reliable D2/3 receptor parameters with [11C]NPA. Methods Six healthy subjects (4 females/2 males) underwent two [11C]NPA scans in the same day. D2/3 receptor binding parameters were estimated using kinetic analysis (using 1- and 2- tissue compartment models) as well as simplified reference tissue method in the three functional subdivisions of the striatum (associative striatum, AST; limbic striatum LST and sensorimotor striatum SMST). The test-retest variability and intraclass correlation coefficient were assessed for distribution volume (VT), binding potential relative to plasma concentration (BPP), and binding potential relative to nondisplaceable uptake (BPND) Results A two-tissue compartment kinetic model adequately described the functional subdivisions of the striatum as well as cerebellum time-activity data. The reproducibility of VT was excellent (≤ 10%) in all regions, for this approach. The reproducibility of both BPP (≤ 12%) and BPND (≤ 10%) was also excellent. The intraclass correlation coefficient of BPP and BPND were acceptable as well (> 0.75) in the three functional subdivisions of the striatum. Although SRTM led to an underestimation of BPND values relative to that estimated by kinetic analysis by 8 to 13%, the values derived using both the methods were reasonably well correlated (r2 = 0.89, n = 84). Both methods were similarly effective at detecting the differences in [11C]NPA BPND between subjects. Conclusion The results of this study indicate that [11C]NPA can be used to measure D2/3 receptors configured in a state of high affinity for the agonists with high reliability and reproducibility in the functional subdivisions of the human striatum. PMID:19301416

  12. A new scale for the assessment of performance and capacity of hand function in children with hemiplegic cerebral palsy: reliability and validity studies.

    PubMed

    Rosa-Rizzotto, M; Visonà Dalla Pozza, L; Corlatti, A; Luparia, A; Marchi, A; Molteni, F; Facchin, P; Pagliano, E; Fedrizzi, E

    2014-10-01

    In hemiplegic children, the recognition of the activity limitation pattern and the possibility of grading its severity are relevant for clinicians while planning interventions, monitoring results, predicting outcomes. Aim of the study is to examine the reliability and validity of Besta Scale, an instrument used to measure in hemiplegic children from 18 months to 12 years of age both grasp on request (capacity) and spontaneous use of upper limb (performance) in bimanual play activities and in ADL. Psychometric analysis of reliability and of validity of the Besta scale was performed. Outpatient study sample Reliability study: A sample of 39 patients was enrolled. The administration of Besta scale was video-recorded in a standardized manner. All videos were scored by 20 independent raters on subsequent viewing. 3 raters randomly selected from the 20-raters group rescored the same video two years later for intra-rater reliability. Intra and inter-rater reliability were calculated using Intraclass Correlation Coefficient (ICC) and Kendall's coefficient (K), respectively. Internal consistency reliability was assessed using Alpha's Chronbach coefficient. Validity study: a sample of 105 children was assessed 5 times (at t0 and 2, 3, 6 and 12 months later) by 20 independent raters. Each patient underwent at the same time to QUEST and Besta scale administration and assessment. Criterion validity was calculated using rho-Pearson coefficient. Reliability study: The inter-rater reliability calculated with Kendall's coefficient resulted moderate K=0.47. The intra-rater (or test-retest) reliability for 3 raters was excellent (ICC=0.927). The Cronbach's alpha for internal consistency was 0.972. Validity study: Besta scale showed a good criterion validity compared to QUEST increasing by age and severity of impairment. Rho Pearson's correlation coefficient r was 0.81 (P<0.0001). Limitations. Besta scales in infants finds hard to distinguish between mild to moderately impaired hand function. Besta scale scoring system is a valid and reliable tool, utilizable in a clinical setting to monitor evolution of unimanual and bimanual manipulation and to distinguish hand's capacity from performance.

  13. Automated spectrophotometric bicarbonate analysis in duodenal juice compared to the back titration method.

    PubMed

    Erchinger, Friedemann; Engjom, Trond; Gudbrandsen, Oddrun Anita; Tjora, Erling; Gilja, Odd H; Dimcevski, Georg

    2016-01-01

    We have recently evaluated a short endoscopic secretin test for exocrine pancreatic function. Bicarbonate concentration in duodenal juice is an important parameter in this test. Measurement of bicarbonate by back titration as the gold standard method is time consuming, expensive and technically difficult, thus a simplified method is warranted. We aimed to evaluate an automated spectrophotometric method in samples spanning the effective range of bicarbonate concentrations in duodenal juice. We also evaluated if freezing of samples before analyses would affect its results. Patients routinely examined with short endoscopic secretin test suspected to have decreased pancreatic function of various reasons were included. Bicarbonate in duodenal juice was quantified by back titration and automatic spectrophotometry. Both fresh and thawed samples were analysed spectrophotometrically. 177 samples from 71 patients were analysed. Correlation coefficient of all measurements was r = 0.98 (p < 0.001). Correlation coefficient of fresh versus frozen samples conducted with automatic spectrophotometry (n = 25): r = 0.96 (p < 0.001) CONCLUSIONS: The measurement of bicarbonate in fresh and thawed samples by automatic spectrophotometrical analysis correlates excellent with the back titration gold standard. This is a major simplification of direct pancreas function testing, and allows a wider distribution of bicarbonate testing in duodenal juice. Extreme values for Bicarbonate concentration achieved by the autoanalyser method have to be interpreted with caution. Copyright © 2016 IAP and EPC. Published by Elsevier India Pvt Ltd. All rights reserved.

  14. Improving Photometry and Stellar Signal Preservation with Pixel-Level Systematic Error Correction

    NASA Technical Reports Server (NTRS)

    Kolodzijczak, Jeffrey J.; Smith, Jeffrey C.; Jenkins, Jon M.

    2013-01-01

    The Kepler Mission has demonstrated that excellent stellar photometric performance can be achieved using apertures constructed from optimally selected CCD pixels. The clever methods used to correct for systematic errors, while very successful, still have some limitations in their ability to extract long-term trends in stellar flux. They also leave poorly correlated bias sources, such as drifting moiré pattern, uncorrected. We will illustrate several approaches where applying systematic error correction algorithms to the pixel time series, rather than the co-added raw flux time series, provide significant advantages. Examples include, spatially localized determination of time varying moiré pattern biases, greater sensitivity to radiation-induced pixel sensitivity drops (SPSDs), improved precision of co-trending basis vectors (CBV), and a means of distinguishing the stellar variability from co-trending terms even when they are correlated. For the last item, the approach enables physical interpretation of appropriately scaled coefficients derived in the fit of pixel time series to the CBV as linear combinations of various spatial derivatives of the pixel response function (PRF). We demonstrate that the residuals of a fit of soderived pixel coefficients to various PRF-related components can be deterministically interpreted in terms of physically meaningful quantities, such as the component of the stellar flux time series which is correlated with the CBV, as well as, relative pixel gain, proper motion and parallax. The approach also enables us to parameterize and assess the limiting factors in the uncertainties in these quantities.

  15. The Attenuation of Correlation Coefficients: A Statistical Literacy Issue

    ERIC Educational Resources Information Center

    Trafimow, David

    2016-01-01

    Much of the science reported in the media depends on correlation coefficients. But the size of correlation coefficients depends, in part, on the reliability with which the correlated variables are measured. Understanding this is a statistical literacy issue.

  16. Measurement of central corneal thickness with optical low-coherence reflectometry and ultrasound pachymetry in normal and post-femtosecond laser in situ keratomileusis eyes.

    PubMed

    Huang, Jinhai; Liao, Na; Savini, Giacomo; Li, Yuanguang; Bao, Fangjun; Yu, Ye; Yu, Ayong; Wang, Qinmei

    2015-02-01

    To determine the repeatability and reproducibility of measurements of central corneal thickness (CCT) using optical low-coherence reflectometry (Lenstar LS900; Haag Streit) in normal eyes and post-femtosecond laser in situ keratomileusis (post-FS-LASIK) eyes and evaluate their agreement with ultrasound (US) pachymetry. CCT was measured using Lenstar and US pachymetry sequentially in normal and post-FS-LASIK eyes by 2 experienced observers. Intraoperator repeatability and interoperator reproducibility were assessed by within-subject standard deviation, test-retest repeatability, coefficient of variation (CoV), and intraclass correlation coefficient. Paired t-tests and Bland-Altman plots were used for analyzing agreement between the 2 devices. In this study, 55 healthy subjects and 50 post-FS-LASIK patients were recruited. Test-retest repeatability of Lenstar was within 10 μm, CoV was less than 1.0%, and intraclass correlation coefficient was more than 0.9 in both normal and post-FS-LASIK groups. Mean difference between these methods was 1.4 ± 4.2 μm and -1.7 ± 5.4 μm, respectively. Moreover, measurements of CCT showed narrow 95% limits of agreement (range, normal group: -6.8 and 9.6 μm; post-FS-LASIK group: -12.4 and 8.9 μm), which implied good agreement. Measurements of CCT using Lenstar showed excellent intraoperator repeatability and interoperator reproducibility both in normal eyes and post-FS-LASIK eyes. Measurements of CCT using Lenstar and US pachymetry showed good agreement and both can be used interchangeably.

  17. A Correction Equation for Jump Height Measured Using the Just Jump System.

    PubMed

    McMahon, John J; Jones, Paul A; Comfort, Paul

    2016-05-01

    To determine the concurrent validity and reliability of the popular Just Jump system (JJS) for determining jump height and, if necessary, provide a correction equation for future reference. Eighteen male college athletes performed 3 bilateral countermovement jumps (CMJs) on 2 JJSs (alternative method) that were placed on top of a force platform (criterion method). Two JJSs were used to establish consistency between systems. Jump height was calculated from flight time obtained from the JJS and force platform. Intraclass correlation coefficients (ICCs) demonstrated excellent within-session reliability of the CMJ height measurement derived from both the JJS (ICC = .96, P < .001) and the force platform (ICC = .96, P < .001). Dependent t tests revealed that the JJS yielded a significantly greater CMJ jump height (0.46 ± 0.09 m vs 0.33 ± 0.08 m) than the force platform (P < .001, Cohen d = 1.39, power = 1.00). There was, however, an excellent relationship between CMJ heights derived from the JJS and force platform (r = .998, P < .001, power = 1.00), with a coefficient of determination (R2) of .995. Therefore, the following correction equation was produced: Criterion jump height = (0.8747 × alternative jump height) - 0.0666. The JJS provides a reliable but overestimated measure of jump height. It is suggested, therefore, that practitioners who use the JJS as part of future work apply the correction equation presented in this study to resultant jump-height values.

  18. MEASURING SPORT-SPECIFIC PHYSICAL ABILITIES IN MALE GYMNASTS: THE MEN'S GYMNASTICS FUNCTIONAL MEASUREMENT TOOL.

    PubMed

    Sleeper, Mark D; Kenyon, Lisa K; Elliott, James M; Cheng, M Samuel

    2016-12-01

    Despite the availability of various field-tests for many competitive sports, a reliable and valid test specifically developed for use in men's gymnastics has not yet been developed. The Men's Gymnastics Functional Measurement Tool (MGFMT) was designed to assess sport-specific physical abilities in male competitive gymnasts. The purpose of this study was to develop the MGFMT by establishing a scoring system for individual test items and to initiate the process of establishing test-retest reliability and construct validity. A total of 83 competitive male gymnasts ages 7-18 underwent testing using the MGFMT. Thirty of these subjects underwent re-testing one week later in order to assess test-retest reliability. Construct validity was assessed using a simple regression analysis between total MGFMT scores and the gymnasts' USA-Gymnastics competitive level to calculate the coefficient of determination (r 2 ). Test-retest reliability was analyzed using Model 1 Intraclass correlation coefficients (ICC). Statistical significance was set at the p<0.05 level. The relationship between total MGFMT scores and subjects' current USA-Gymnastics competitive level was found to be good (r 2  = 0.63). Reliability testing of the MGFMT composite test score showed excellent test-retest reliability over a one-week period (ICC = 0.97). Test-retest reliability of the individual component tests ranged from good to excellent (ICC = 0.75-0.97). The results of this study provide initial support for the construct validity and test-retest reliability of the MGFMT. Level 3.

  19. Investigation of four self-report instruments (FABT, TSK-HC, Back-PAQ, HC-PAIRS) to measure healthcare practitioners' attitudes and beliefs toward low back pain: Reliability, convergent validity and survey of New Zealand osteopaths and manipulative physiotherapists.

    PubMed

    Moran, Robert W; Rushworth, Wendy M; Mason, Jesse

    2017-12-01

    Healthcare practitioner beliefs influence advice and management provided to patients with back pain. Several instruments measuring practitioner beliefs have been developed but psychometric properties for some have not been investigated. To investigate internal consistency, test-retest reliability and convergent validity of the Fear Avoidance Beliefs Tool (FABT), the Tampa Scale of Kinesiophobia for Health Care Providers (TSK-HC), the Back Pain Attitudes Questionnaire (Back-PAQ), and the Health Care Pain and Impairment Relationship Scale (HC-PAIRS). A secondary aim was to explore beliefs of New Zealand osteopaths and physiotherapists regarding low back pain. FABT, TSK-HC, Back-PAQ, and HC-PAIRS were administered twice, 14 days apart. Data from 91 osteopaths and 35 physiotherapists were analysed. The FABT, TSK-HC and Back-PAQ each demonstrated excellent internal consistency, (Cronbach's α = 0.92, 0.91, and 0.91 respectively), and excellent test-retest reliability (lower limit of 95% CI for intraclass correlation coefficient >0.75). Correlations between instruments (Pearson's r = 0.51 to 0.77, p < 0.001) demonstrated good convergent validity. There was a medium to large effect (Cohen's d > 0.47) for mean differences in scores, for all instruments, between professions. This study found excellent internal consistency, test-retest reliability and good convergent validity for the FABT, TSK-HC, and Back-PAQ. Previously reported internal consistency, test-retest and convergent validity of the HC-PAIRS were confirmed, and test-retest reliability was excellent. There were significant scoring differences on each instrument between professions, and while both groups demonstrated fear avoidant beliefs, physiotherapist respondent scores indicated that as a group, they held fewer fear-avoidant beliefs than osteopath respondents. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Multiple description distributed image coding with side information for mobile wireless transmission

    NASA Astrophysics Data System (ADS)

    Wu, Min; Song, Daewon; Chen, Chang Wen

    2005-03-01

    Multiple description coding (MDC) is a source coding technique that involves coding the source information into multiple descriptions, and then transmitting them over different channels in packet network or error-prone wireless environment to achieve graceful degradation if parts of descriptions are lost at the receiver. In this paper, we proposed a multiple description distributed wavelet zero tree image coding system for mobile wireless transmission. We provide two innovations to achieve an excellent error resilient capability. First, when MDC is applied to wavelet subband based image coding, it is possible to introduce correlation between the descriptions in each subband. We consider using such a correlation as well as potentially error corrupted description as side information in the decoding to formulate the MDC decoding as a Wyner Ziv decoding problem. If only part of descriptions is lost, however, their correlation information is still available, the proposed Wyner Ziv decoder can recover the description by using the correlation information and the error corrupted description as side information. Secondly, in each description, single bitstream wavelet zero tree coding is very vulnerable to the channel errors. The first bit error may cause the decoder to discard all subsequent bits whether or not the subsequent bits are correctly received. Therefore, we integrate the multiple description scalar quantization (MDSQ) with the multiple wavelet tree image coding method to reduce error propagation. We first group wavelet coefficients into multiple trees according to parent-child relationship and then code them separately by SPIHT algorithm to form multiple bitstreams. Such decomposition is able to reduce error propagation and therefore improve the error correcting capability of Wyner Ziv decoder. Experimental results show that the proposed scheme not only exhibits an excellent error resilient performance but also demonstrates graceful degradation over the packet loss rate.

  1. Pancreatitis Quality of Life Instrument: A Psychometric Evaluation.

    PubMed

    Wassef, Wahid; DeWitt, John; McGreevy, Kathleen; Wilcox, Mel; Whitcomb, David; Yadav, Dhiraj; Amann, Stephen; Mishra, Girish; Alkaade, Samer; Romagnuolo, Joseph; Stevens, Tyler; Vargo, John; Gardner, Timothy; Singh, Vikesh; Park, Walter; Hartigan, Celia; Barton, Bruce; Bova, Carol

    2016-08-01

    Chronic pancreatitis is a significant medical problem that impacts a large number of patients worldwide. In 2014, we developed a disease-specific instrument for the evaluation of quality of life in this group of patients: pancreatitis quality of life instrument (PANQOLI). The goal of this study was to evaluate its psychometric properties: its reliability and its construct validity. This is a cross-sectional multi-center study that involved 12 pancreatic disease centers. Patients who met the inclusion/exclusion criteria for chronic pancreatitis were invited to participate. Those who accepted were asked to complete seven questionnaires/instruments. Only patients who completed the PANQOLI were included in the study. Its reliability and its construct validity were tested. A total of 159 patients completed the PANQOLI and were included in the study. They had a mean age of 49.03, 49% were male, and 84% were Caucasian. Six of the 24 items on the scale were removed because of lack of inter-item correlation, redundancy, or lack of correlation to quality of life issues. The final 18-item scale had excellent reliability (Cronbach's alpha coefficient: 0.914) and excellent construct validity with good correlation to generic quality of life instruments (SF-12 and EORTC QLQ-C30/QLQ-PAN26) and lack of correlation to non-quality of life instruments (MAST and DAST). Through exploratory factor analysis, the PANQOLI was found to consist of four subscales: emotional function scale, role function scale, physical function scale, and "self-worth" scale. PANQOLI is the first disease-specific instrument to be developed and validated for the evaluation of quality of life in chronic pancreatitis patients. It has a unique subscale for "self-worth" that differentiates it from other generic instruments. Studies are currently under way to evaluate its use in other populations not included in this study.

  2. Identification of Correlated GRACE Monthly Harmonic Coefficients Using Pattern Recognition and Neural Networks

    NASA Astrophysics Data System (ADS)

    Piretzidis, D.; Sra, G.; Sideris, M. G.

    2016-12-01

    This study explores new methods for identifying correlation errors in harmonic coefficients derived from monthly solutions of the Gravity Recovery and Climate Experiment (GRACE) satellite mission using pattern recognition and neural network algorithms. These correlation errors are evidenced in the differences between monthly solutions and can be suppressed using a de-correlation filter. In all studies so far, the implementation of the de-correlation filter starts from a specific minimum order (i.e., 11 for RL04 and 38 for RL05) until the maximum order of the monthly solution examined. This implementation method has two disadvantages, namely, the omission of filtering correlated coefficients of order less than the minimum order and the filtering of uncorrelated coefficients of order higher than the minimum order. In the first case, the filtered solution is not completely free of correlated errors, whereas the second case results in a monthly solution that suffers from loss of geophysical signal. In the present study, a new method of implementing the de-correlation filter is suggested, by identifying and filtering only the coefficients that show indications of high correlation. Several numerical and geometric properties of the harmonic coefficient series of all orders are examined. Extreme cases of both correlated and uncorrelated coefficients are selected, and their corresponding properties are used to train a two-layer feed-forward neural network. The objective of the neural network is to identify and quantify the correlation by providing the probability of an order of coefficients to be correlated. Results show good performance of the neural network, both in the validation stage of the training procedure and in the subsequent use of the trained network to classify independent coefficients. The neural network is also capable of identifying correlated coefficients even when a small number of training samples and neurons are used (e.g.,100 and 10, respectively).

  3. Estimation of health-related-quality of life depends on which utility measure is selected for patients with carpal tunnel syndrome.

    PubMed

    Nazari, Goris; MacDermid, Joy C; Bain, James; Levis, Carolyn M; Thoma, Achilleas

    Cross-sectional. Carpal tunnel syndrome (CTS) refers to the compression neuropathy of the median nerve at the wrist. To establish the interinstrument reliability, convergent construct validity, and the levels of agreement of health utility indexes 2 and 3 (HUI-2 and HUI-3), EuroQol 5-dimensions (EQ-5D), EuroQol-visual analog scale (EQ-VAS) and to determine the difference of these utility measures based on age and gender in patients with carpal tunnel syndrome. Seventy-four patients with a confirmed diagnosis of carpal tunnel syndrome completed the 3 questionnaires and EQ-VAS a month before surgery. Demographic characteristics were reported. Intraclass correlation coefficients were used to assess relative interinstrument reliability. Pearson correlation coefficients (r) were used to establish convergent construct validity. Bland-Altman plots and t tests were used to describe the levels of agreement between the 4 utility measures. A 2-way analysis of variance was performed to determine the effect of age and gender on the utility measures; HUI-2, HUI-3, and EQ-5D. The intraclass correlation coefficients were 0.85 for HUI-3 vs HUI-2 and 0.80 for HUI-2 vs EQ-VAS. Pearson correlation coefficients ranged from 0.60 to 0.89; HUI-3 vs HUI-2: 0.89, and HUI-3 vs EQ-5D: 0.60. One-sample t test demonstrated significant differences between HUI-3 vs HUI-2, HUI-3 vs EQ-5D, and HUI-3 vs EQ-VAS measures, with mean differences of -0.12, -0.15, and -0.14, respectively. A 2-way analysis of variance test controlling for age and gender indicated neither as predictors of outcome scores. The HUI-3 vs HUI-2 and HUI-2 vs EQ-VAS demonstrated excellent interinstrument relative reliability measures. The HUI-3 vs HUI-2 displayed very strong convergent construct validity measures, and strong validity measures were established between the remaining utility measures. In addition, the pair-wise utility comparisons demonstrated minimal bias between HUI-2 vs EQ-5D, HUI-2 vs EQ-VAS, and EQ-VAS vs EQ-5D measures. N/A. N/A. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  4. Test-Retest Reliability of Rating of Perceived Exertion and Agreement With 1-Repetition Maximum in Adults.

    PubMed

    Bove, Allyn M; Lynch, Andrew D; DePaul, Samantha M; Terhorst, Lauren; Irrgang, James J; Fitzgerald, G Kelley

    2016-09-01

    Study Design Clinical measurement. Background It has been suggested that rating of perceived exertion (RPE) may be a useful alternative to 1-repetition maximum (1RM) to determine proper resistance exercise dosage. However, the test-retest reliability of RPE for resistance exercise has not been determined. Additionally, prior research regarding the relationship between 1RM and RPE is conflicting. Objectives The purpose of this study was to (1) determine test-retest reliability of RPE related to resistance exercise and (2) assess agreement between percentages of 1RM and RPE during quadriceps resistance exercise. Methods A sample of participants with and without knee pathology completed a series of knee extension exercises and rated the perceived difficulty of each exercise on a 0-to-10 RPE scale, then repeated the procedure 1 to 2 weeks later for test-retest reliability. To determine agreement between RPE and 1RM, participants completed knee extension exercises at various percentages of their 1RM (10% to 130% of predicted 1RM) and rated the perceived difficulty of each exercise on a 0-to-10 RPE scale. Percent agreement was calculated between the 1RM and RPE at each resistance interval. Results The intraclass correlation coefficient indicated excellent test-retest reliability of RPE for quadriceps resistance exercises (intraclass correlation coefficient = 0.895; 95% confidence interval: 0.866, 0.918). Overall percent agreement between RPE and 1RM was 60%, but agreement was poor within the ranges that would typically be used for training (50% 1RM for muscle endurance, 70% 1RM and greater for strength). Conclusion Test-retest reliability of perceived exertion during quadriceps resistance exercise was excellent. However, agreement between the RPE and 1RM was poor, especially in common training zones for knee extensor strengthening. J Orthop Sports Phys Ther 2016;46(9):768-774. Epub 5 Aug 2016. doi:10.2519/jospt.2016.6498.

  5. A practical and highly sensitive C3N4-TYR fluorescent probe for convenient detection of dopamine

    NASA Astrophysics Data System (ADS)

    Li, Hao; Yang, Manman; Liu, Juan; Zhang, Yalin; Yang, Yanmei; Huang, Hui; Liu, Yang; Kang, Zhenhui

    2015-07-01

    The C3N4-tyrosinase (TYR) hybrid is a highly accurate, sensitive and simple fluorescent probe for the detection of dopamine (DOPA). Under optimized conditions, the relative fluorescence intensity of C3N4-TYR is proportional to the DOPA concentration in the range from 1 × 10-3 to 3 × 10-8 mol L-1 with a correlation coefficient of 0.995. In the present system, the detection limit achieved is as low as 3 × 10-8 mol L-1. Notably, these quantitative detection results for clinical samples are comparable to those of high performance liquid chromatography. Moreover, the enzyme-encapsulated C3N4 sensing arrays on both glass slide and test paper were evaluated, which revealed sensitive detection and excellent stability. The results reported here provide a new approach for the design of a multifunctional nanosensor for the detection of bio-molecules.The C3N4-tyrosinase (TYR) hybrid is a highly accurate, sensitive and simple fluorescent probe for the detection of dopamine (DOPA). Under optimized conditions, the relative fluorescence intensity of C3N4-TYR is proportional to the DOPA concentration in the range from 1 × 10-3 to 3 × 10-8 mol L-1 with a correlation coefficient of 0.995. In the present system, the detection limit achieved is as low as 3 × 10-8 mol L-1. Notably, these quantitative detection results for clinical samples are comparable to those of high performance liquid chromatography. Moreover, the enzyme-encapsulated C3N4 sensing arrays on both glass slide and test paper were evaluated, which revealed sensitive detection and excellent stability. The results reported here provide a new approach for the design of a multifunctional nanosensor for the detection of bio-molecules. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr03316k

  6. Trial Vocal Fold Injection Predicts Thyroplasty Outcomes in Nonparalytic Glottic Incompetence.

    PubMed

    Dumberger, Lukas D; Overton, Lewis; Buckmire, Robert A; Shah, Rupali N

    2017-04-01

    Trial vocal fold injection (TVFI) may be used prior to permanent medialization when voice outcome is uncertain. We aimed to determine whether voice outcomes of TVFI are predictive of, or correlate with outcomes after type I Gore-Tex medialization thyroplasty (GMT) in patients with nonparalytic glottic incompetence (GI). Thirty-five patients with nonparalytic GI who underwent TVFI followed by GMT were retrospectively reviewed. Change in voice-related quality of life (VRQOL) after TVFI was compared to change in VRQOL 3 to 9 months after GMT. Similar comparisons were made for change in glottal function index (GFI) and change in grade, roughness, breathiness, asthenia, and strain (GRBAS). Sample correlation coefficients were calculated. Change in VRQOL after TVFI showed good correlation with change in VRQOL after GMT, r = 0.55. Change in GFI after TVFI showed strong correlation with change in GFI after GMT, r = 0.74. Change in GRBAS after TVFI showed excellent correlation with change in GRBAS after GMT, r = 0.90. The TVFI is a useful tool in nonparalytic GI when outcomes from glottic closure procedures are not clear. Voice outcome measures after TVFI strongly correlate with outcomes from GMT. These data may be used to more confidently counsel patients regarding their predicted outcomes of permanent medialization.

  7. Diagnosing cysts with correlation coefficient images from 2-dimensional freehand elastography.

    PubMed

    Booi, Rebecca C; Carson, Paul L; O'Donnell, Matthew; Richards, Michael S; Rubin, Jonathan M

    2007-09-01

    We compared the diagnostic potential of using correlation coefficient images versus elastograms from 2-dimensional (2D) freehand elastography to characterize breast cysts. In this preliminary study, which was approved by the Institutional Review Board and compliant with the Health Insurance Portability and Accountability Act, we imaged 4 consecutive human subjects (4 cysts, 1 biopsy-verified benign breast parenchyma) with freehand 2D elastography. Data were processed offline with conventional 2D phase-sensitive speckle-tracking algorithms. The correlation coefficient in the cyst and surrounding tissue was calculated, and appearances of the cysts in the correlation coefficient images and elastograms were compared. The correlation coefficient in the cysts was considerably lower (14%-37%) than in the surrounding tissue because of the lack of sufficient speckle in the cysts, as well as the prominence of random noise, reverberations, and clutter, which decorrelated quickly. Thus, the cysts were visible in all correlation coefficient images. In contrast, the elastograms associated with these cysts each had different elastographic patterns. The solid mass in this study did not have the same high decorrelation rate as the cysts, having a correlation coefficient only 2.1% lower than that of surrounding tissue. Correlation coefficient images may produce a more direct, reliable, and consistent method for characterizing cysts than elastograms.

  8. Correlation of iodine uptake and perfusion parameters between dual-energy CT imaging and first-pass dual-input perfusion CT in lung cancer.

    PubMed

    Chen, Xiaoliang; Xu, Yanyan; Duan, Jianghui; Li, Chuandong; Sun, Hongliang; Wang, Wu

    2017-07-01

    To investigate the potential relationship between perfusion parameters from first-pass dual-input perfusion computed tomography (DI-PCT) and iodine uptake levels estimated from dual-energy CT (DE-CT).The pre-experimental part of this study included a dynamic DE-CT protocol in 15 patients to evaluate peak arterial enhancement of lung cancer based on time-attenuation curves, and the scan time of DE-CT was determined. In the prospective part of the study, 28 lung cancer patients underwent whole-volume perfusion CT and single-source DE-CT using 320-row CT. Pulmonary flow (PF, mL/min/100 mL), aortic flow (AF, mL/min/100 mL), and a perfusion index (PI = PF/[PF + AF]) were automatically generated by in-house commercial software using the dual-input maximum slope method for DI-PCT. For the dual-energy CT data, iodine uptake was estimated by the difference (λ) and the slope (λHU). λ was defined as the difference of CT values between 40 and 70 KeV monochromatic images in lung lesions. λHU was calculated by the following equation: λHU = |λ/(70 - 40)|. The DI-PCT and DE-CT parameters were analyzed by Pearson/Spearman correlation analysis, respectively.All subjects were pathologically proved as lung cancer patients (including 16 squamous cell carcinoma, 8 adenocarcinoma, and 4 small cell lung cancer) by surgery or CT-guided biopsy. Interobserver reproducibility in DI-PCT (PF, AF, PI) and DE-CT (λ, λHU) were relatively good to excellent (intraclass correlation coefficient [ICC]Inter = 0.8726-0.9255, ICCInter = 0.8179-0.8842; ICCInter = 0.8881-0.9177, ICCInter = 0.9820-0.9970, ICCInter = 0.9780-0.9971, respectively). Correlation coefficient between λ and AF, and PF were as follows: 0.589 (P < .01) and 0.383 (P < .05). Correlation coefficient between λHU and AF, and PF were as follows: 0.564 (P < .01) and 0.388 (P < .05).Both the single-source DE-CT and dual-input CT perfusion analysis method can be applied to assess blood supply of lung cancer patients. Preliminary results demonstrated that the iodine uptake relevant parameters derived from DE-CT significantly correlated with perfusion parameters derived from DI-PCT.

  9. Development and Validation of a Portable and Inexpensive Tool to Measure the Drop Vertical Jump Using the Microsoft Kinect V2.

    PubMed

    Gray, Aaron D; Willis, Brad W; Skubic, Marjorie; Huo, Zhiyu; Razu, Swithin; Sherman, Seth L; Guess, Trent M; Jahandar, Amirhossein; Gulbrandsen, Trevor R; Miller, Scott; Siesener, Nathan J

    Noncontact anterior cruciate ligament (ACL) injury in adolescent female athletes is an increasing problem. The knee-ankle separation ratio (KASR), calculated at initial contact (IC) and peak flexion (PF) during the drop vertical jump (DVJ), is a measure of dynamic knee valgus. The Microsoft Kinect V2 has shown promise as a reliable and valid marker-less motion capture device. The Kinect V2 will demonstrate good to excellent correlation between KASR results at IC and PF during the DVJ, as compared with a "gold standard" Vicon motion analysis system. Descriptive laboratory study. Level 2. Thirty-eight healthy volunteer subjects (20 male, 18 female) performed 5 DVJ trials, simultaneously measured by a Vicon MX-T40S system, 2 AMTI force platforms, and a Kinect V2 with customized software. A total of 190 jumps were completed. The KASR was calculated at IC and PF during the DVJ. The intraclass correlation coefficient (ICC) assessed the degree of KASR agreement between the Kinect and Vicon systems. The ICCs of the Kinect V2 and Vicon KASR at IC and PF were 0.84 and 0.95, respectively, showing excellent agreement between the 2 measures. The Kinect V2 successfully identified the KASR at PF and IC frames in 182 of 190 trials, demonstrating 95.8% reliability. The Kinect V2 demonstrated excellent ICC of the KASR at IC and PF during the DVJ when compared with the Vicon system. A customized Kinect V2 software program demonstrated good reliability in identifying the KASR at IC and PF during the DVJ. Reliable, valid, inexpensive, and efficient screening tools may improve the accessibility of motion analysis assessment of adolescent female athletes.

  10. Translation and validation of the Dutch new Knee Society Scoring System ©.

    PubMed

    Van Der Straeten, Catherine; Witvrouw, Erik; Willems, Tine; Bellemans, Johan; Victor, Jan

    2013-11-01

    A new version of The Knee Society Knee Scoring System(©) (KSS) has recently been developed. Before this scale can be used in non-English-speaking populations, it has to be translated and validated for a particular population. We evaluated the construct and content validity, the test-retest reliability, and the internal consistency of the Dutch version of the New Knee Society KSS. A Dutch translation was performed using a forward-backward translation protocol. We tested the construct validity of the Dutch New KSS by comparing it with the Dutch versions of the WOMAC, Knee Injury and Osteoarthritis Outcome Score (KOOS), and SF-12 scores in 137 patients undergoing total knee arthroplasty (TKA). Content validity was assessed by comparing pre- and postoperative scores and by checking floor and ceiling effects. To evaluate test-retest reliability and consistency, 47 patients completed the questionnaire a second time with a mean of 8 days interval (range, 2-20 days) between tests. Construct validity was demonstrated because the Dutch New KSS correlated well with the Dutch WOMAC (r = -0.751; p < 0.001), Dutch KOOS (r = -0.723; p < 0.001), and Dutch SF-12 (r = 0.569; p < 0.001). There was a significant difference between pre- and postoperative scores (p < 0.001) in line with the other scores. Test-retest reliability proved excellent with an intraclass correlation coefficient between 0.73 and 0.92 depending on the domain tested. Consistency as indicated by Cronbach's alpha ranging from 0.84 to 0.96 was good to excellent. As demonstrated by the validation procedure, the Dutch New KSS is an excellent instrument to evaluate TKA outcome in Dutch-speaking patients.

  11. A New Methodology of Spatial Cross-Correlation Analysis

    PubMed Central

    Chen, Yanguang

    2015-01-01

    Spatial correlation modeling comprises both spatial autocorrelation and spatial cross-correlation processes. The spatial autocorrelation theory has been well-developed. It is necessary to advance the method of spatial cross-correlation analysis to supplement the autocorrelation analysis. This paper presents a set of models and analytical procedures for spatial cross-correlation analysis. By analogy with Moran’s index newly expressed in a spatial quadratic form, a theoretical framework is derived for geographical cross-correlation modeling. First, two sets of spatial cross-correlation coefficients are defined, including a global spatial cross-correlation coefficient and local spatial cross-correlation coefficients. Second, a pair of scatterplots of spatial cross-correlation is proposed, and the plots can be used to visually reveal the causality behind spatial systems. Based on the global cross-correlation coefficient, Pearson’s correlation coefficient can be decomposed into two parts: direct correlation (partial correlation) and indirect correlation (spatial cross-correlation). As an example, the methodology is applied to the relationships between China’s urbanization and economic development to illustrate how to model spatial cross-correlation phenomena. This study is an introduction to developing the theory of spatial cross-correlation, and future geographical spatial analysis might benefit from these models and indexes. PMID:25993120

  12. A new methodology of spatial cross-correlation analysis.

    PubMed

    Chen, Yanguang

    2015-01-01

    Spatial correlation modeling comprises both spatial autocorrelation and spatial cross-correlation processes. The spatial autocorrelation theory has been well-developed. It is necessary to advance the method of spatial cross-correlation analysis to supplement the autocorrelation analysis. This paper presents a set of models and analytical procedures for spatial cross-correlation analysis. By analogy with Moran's index newly expressed in a spatial quadratic form, a theoretical framework is derived for geographical cross-correlation modeling. First, two sets of spatial cross-correlation coefficients are defined, including a global spatial cross-correlation coefficient and local spatial cross-correlation coefficients. Second, a pair of scatterplots of spatial cross-correlation is proposed, and the plots can be used to visually reveal the causality behind spatial systems. Based on the global cross-correlation coefficient, Pearson's correlation coefficient can be decomposed into two parts: direct correlation (partial correlation) and indirect correlation (spatial cross-correlation). As an example, the methodology is applied to the relationships between China's urbanization and economic development to illustrate how to model spatial cross-correlation phenomena. This study is an introduction to developing the theory of spatial cross-correlation, and future geographical spatial analysis might benefit from these models and indexes.

  13. Perturbative two- and three-loop coefficients from large β Monte Carlo

    NASA Astrophysics Data System (ADS)

    Lepage, G. P.; Mackenzie, P. B.; Shakespeare, N. H.; Trottier, H. D.

    Perturbative coefficients for Wilson loops and the static quark self-energy are extracted from Monte Carlo simulations at large β on finite volumes, where all the lattice momenta are large. The Monte Carlo results are in excellent agreement with perturbation theory through second order. New results for third order coefficients are reported. Twisted boundary conditions are used to eliminate zero modes and to suppress Z3 tunneling.

  14. Perturbative two- and three-loop coefficients from large b Monte Carlo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    G.P. Lepage; P.B. Mackenzie; N.H. Shakespeare

    1999-10-18

    Perturbative coefficients for Wilson loops and the static quark self-energy are extracted from Monte Carlo simulations at large {beta} on finite volumes, where all the lattice momenta are large. The Monte Carlo results are in excellent agreement with perturbation theory through second order. New results for third order coefficients are reported. Twisted boundary conditions are used to eliminate zero modes and to suppress Z{sub 3} tunneling.

  15. Translation and validation of a Nepalese version of the Psychosocial Impact of Dental Aesthetic Questionnaire (PIDAQ).

    PubMed

    Singh, Varun Pratap; Singh, Rajkumar

    2014-03-01

    The aim of this study was to develop a reliable and valid Nepali version of the Psychosocial Impact of Dental Aesthetic Questionnaire (PIDAQ). Cross-sectional descriptive validation study. B.P. Koirala Institute of Health Sciences, Dharan, Nepal. A rigorous translation process including conceptual and semantic evaluation, translation, back translation and pre-testing was carried out. Two hundred and fifty-two undergraduates, including equal numbers of males and females with an age ranging from 18 to 29 years (mean age: 22·33±2·114 years), participated in this study. Reliability was assessed by Cronbach's alpha coefficient and the coefficient of correlation was used to assess correlation between items and test-retest reliability. The construct validity was tested by factorial analysis. Convergent construct validity was tested by comparison of PIDAQ scores with the aesthetic component of the index of orthodontic treatment needs (IOTN-AC) and perception of occlusion scale (POS), respectively. Discriminant construct validity was assessed by differences in score for those who demand treatment and those who did not. The response rate was 100%. One hundred and twenty-three individuals had a demand for orthodontic treatment. The Nepali PIDAQ had excellent reliability with Cronbach's alpha of 0·945, corrected item correlation between 0·525 and 0·790 and overall test-retest reliability of 0·978. The construct validity was good with formation of a new sub-domain 'Dental self-consciousness'. The scale had good correlation with IOTN-AC and POS fulfilling convergent construct validity. The discriminant construct validity was proved by significant differences in scores for subjects with demand and without demand for treatment. To conclude, Nepali version of PIDAQ has good psychometric properties and can be used effectively in this population group for further research.

  16. Validity of the occupational sitting and physical activity questionnaire.

    PubMed

    Chau, Josephine Y; Van Der Ploeg, Hidde P; Dunn, Scott; Kurko, John; Bauman, Adrian E

    2012-01-01

    Sitting at work is an emerging occupational health risk. Few instruments designed for use in population-based research measure occupational sitting and standing as distinct behaviors. This study aimed to develop and validate brief measure of occupational sitting and physical activity. A convenience sample (n = 99, 61% female) was recruited from two medium-sized workplaces and by word-of-mouth in Sydney, Australia. Participants completed the newly developed Occupational Sitting and Physical Activity Questionnaire (OSPAQ) and a modified version of the MONICA Optional Study on Physical Activity Questionnaire (modified MOSPA-Q) twice, 1 wk apart. Participants also wore an ActiGraph accelerometer for the 7 d in between the test and retest. Analyses determined test-retest reliability with intraclass correlation coefficients and assessed criterion validity against accelerometers using the Spearman ρ. The test-retest intraclass correlation coefficients for occupational sitting, standing, and walking for OSPAQ ranged from 0.73 to 0.90, while that for the modified MOSPA-Q ranged from 0.54 to 0.89. Comparison of sitting measures with accelerometers showed higher Spearman correlations for the OSPAQ (r = 0.65) than for the modified MOSPA-Q (r = 0.52). Criterion validity correlations for occupational standing and walking measures were comparable for both instruments with accelerometers (standing: r = 0.49; walking: r = 0.27-0.29). The OSPAQ has excellent test-retest reliability and moderate validity for estimating time spent sitting and standing at work and is comparable to existing occupational physical activity measures for assessing time spent walking at work. The OSPAQ brief instrument measures sitting and standing at work as distinct behaviors and would be especially suitable in national health surveys, prospective cohort studies, and other studies that are limited by space constraints for questionnaire items.

  17. Can we have an overall osteoarthritis severity score for the patellofemoral joint using magnetic resonance imaging? Reliability and validity.

    PubMed

    Kobayashi, Sarah; Peduto, Anthony; Simic, Milena; Fransen, Marlene; Refshauge, Kathryn; Mah, Jean; Pappas, Evangelos

    2018-04-01

    This work aimed to assess inter-rater reliability and agreement of a magnetic resonance imaging (MRI)-based Kellgren and Lawrence (K&L) grading for patellofemoral joint osteoarthritis (OA) and to validate it against the MRI Osteoarthritis Knee Score (MOAKS). MRI scans from people aged 45 to 75 years with chronic knee pain participating in a randomised clinical trial evaluating dietary supplements were utilised. Fifty participants were randomly selected and scored using the MRI-based K&L grading using axial and sagittal MRI scans. Raters conducted inter-rater reliability, blinded to clinical information, radiology reports and other rater results. Intra- and inter-rater reliability and agreement were evaluated using the intra-class correlation coefficient (ICC) and Cohen's weighted kappa. There was a 2-week interval between the first and second readings for intra-rater reliability. Validity was assessed using the MOAKS and evaluated using Spearman's correlation coefficient. Intra-rater reliability of the K&L system was excellent: ICC 0.91 (95% CI 0.82-0.95); weighted kappa (ĸ = 0.69). Inter-rater reliability was high (ICC 0.88; 95% CI 0.79-0.93), while agreement between raters was moderate (ĸ = 0.49-0.57). Validity analysis demonstrated a strong correlation between the total MOAKS features score and the K&L grading system (ρ = 0.62-0.67) but weak correlations when compared with individual MOAKS features (ρ = 0.19-0.61). The high reliability and good agreement show consistency in grading the severity of patellofemoral OA with the MRI-based K&L score. Our validity results suggest that the scale may be useful, particularly in the clinical environment. Future research should validate this method against clinical findings.

  18. The validity and reliability of the Thai version of the Kujala score for patients with patellofemoral pain syndrome.

    PubMed

    Apivatgaroon, Adinun; Angthong, Chayanin; Sanguanjit, Prakasit; Chernchujit, Bancha

    2016-10-01

    To develop a Thai version of the Kujala score and show the evaluation of the validity and reliability of the score. The Thai version of the Kujala score was developed using the forward-backward translation protocol. The 49 PFPS patients answered the Thai version of questionnaires including the Kujala score, Short Form-36 (SF-36) and International Knee Documentation Committee (IKDC) Subjective Knee Form. The validity between the scores has been tested. The reliability was assessed using test-retest reliability and internal consistency. The Thai version of the Kujala score showed a good correlation with Thai IKDC Subjective Knee Form (Pearson's correlation coefficient; r = 0.74: p < 0.01) and moderate correlation with the Thai SF-36 subscales of physical component summary, total score and role physical (r = 0.586, 0.571 and 0.524, respectively: p < 0.01). The test-retest reliability was excellent with an intra-class correlation coefficient of 0.908 (p < 0.001; 95% CI [0.842-0.947]). The internal consistency was strong with Cronbach's alpha of 0.952 (p < 0.001). No floor and ceiling effects were observed. The Thai version of the Kujala score has shown good validity and reliability. This score can be effectively used for evaluating Thai patients with patellofemoral pain syndrome. Implications for Rehabilitation The Kujala score is a self-administered questionnaire for patients with patellofemoral pain syndrome (PFPS). The validity and reliability of the Thai version of Kujala are compatible with other versions (Turkish, Chinese and Persian version). The Thai version of Kujala has been shown to have validity and reliability in Thai PFPS patients and can be used for clinical evaluation and also in the research work.

  19. Random matrix theory analysis of cross-correlations in the US stock market: Evidence from Pearson’s correlation coefficient and detrended cross-correlation coefficient

    NASA Astrophysics Data System (ADS)

    Wang, Gang-Jin; Xie, Chi; Chen, Shou; Yang, Jiao-Jiao; Yang, Ming-Yan

    2013-09-01

    In this study, we first build two empirical cross-correlation matrices in the US stock market by two different methods, namely the Pearson’s correlation coefficient and the detrended cross-correlation coefficient (DCCA coefficient). Then, combining the two matrices with the method of random matrix theory (RMT), we mainly investigate the statistical properties of cross-correlations in the US stock market. We choose the daily closing prices of 462 constituent stocks of S&P 500 index as the research objects and select the sample data from January 3, 2005 to August 31, 2012. In the empirical analysis, we examine the statistical properties of cross-correlation coefficients, the distribution of eigenvalues, the distribution of eigenvector components, and the inverse participation ratio. From the two methods, we find some new results of the cross-correlations in the US stock market in our study, which are different from the conclusions reached by previous studies. The empirical cross-correlation matrices constructed by the DCCA coefficient show several interesting properties at different time scales in the US stock market, which are useful to the risk management and optimal portfolio selection, especially to the diversity of the asset portfolio. It will be an interesting and meaningful work to find the theoretical eigenvalue distribution of a completely random matrix R for the DCCA coefficient because it does not obey the Marčenko-Pastur distribution.

  20. Reliability of measuring sciatic and tibial nerve movement with diagnostic ultrasound during a neural mobilisation technique.

    PubMed

    Ellis, Richard; Hing, Wayne; Dilley, Andrew; McNair, Peter

    2008-08-01

    Diagnostic ultrasound provides a technique whereby real-time, in vivo analysis of peripheral nerve movement is possible. This study measured sciatic nerve movement during a "slider" neural mobilisation technique (ankle dorsiflexion/plantar flexion and cervical extension/flexion). Transverse and longitudinal movement was assessed from still ultrasound images and video sequences by using frame-by-frame cross-correlation software. Sciatic nerve movement was recorded in the transverse and longitudinal planes. For transverse movement, at the posterior midthigh (PMT) the mean value of lateral sciatic nerve movement was 3.54 mm (standard error of measurement [SEM] +/- 1.18 mm) compared with anterior-posterior/vertical (AP) movement of 1.61 mm (SEM +/- 0.78 mm). At the popliteal crease (PC) scanning location, lateral movement was 6.62 mm (SEM +/- 1.10 mm) compared with AP movement of 3.26 mm (SEM +/- 0.99 mm). Mean longitudinal sciatic nerve movement at the PMT was 3.47 mm (SEM +/- 0.79 mm; n = 27) compared with the PC of 5.22 mm (SEM +/- 0.05 mm; n = 3). The reliability of ultrasound measurement of transverse sciatic nerve movement was fair to excellent (Intraclass correlation coefficient [ICC] = 0.39-0.76) compared with excellent (ICC = 0.75) for analysis of longitudinal movement. Diagnostic ultrasound presents a reliable, noninvasive, real-time, in vivo method for analysis of sciatic nerve movement.

  1. Assessment of reliability, validity, responsiveness and minimally important change of the German Hip dysfunction and osteoarthritis outcome score (HOOS) in patients with osteoarthritis of the hip.

    PubMed

    Arbab, Dariusch; van Ochten, Johannes H M; Schnurr, Christoph; Bouillon, Bertil; König, Dietmar

    2017-12-01

    Patient-reported outcome measures are a critical tool in evaluating the efficacy of orthopedic procedures. The intention of this study was to evaluate reliability, validity, responsiveness and minimally important change of the German version of the Hip dysfunction and osteoarthritis outcome score (HOOS). The German HOOS was investigated in 251 consecutive patients before and 6 months after total hip arthroplasty. All patients completed HOOS, Oxford-Hip Score, Short-Form (SF-36) and numeric scales for pain and disability. Test-retest reliability, internal consistency, floor and ceiling effects, construct validity and minimal important change were analyzed. The German HOOS demonstrated excellent test-retest reliability with intraclass correlation coefficient values > 0.7. Cronbach´s alpha values demonstrated strong internal consistency. As hypothesized, HOOS subscales strongly correlated with corresponding OHS and SF-36 domains. All subscales showed excellent (effect size/standardized response means > 0.8) responsiveness between preoperative assessment and postoperative follow-up. The HOOS and all subdomains showed higher changes than the minimal detectable change which indicates true changes. The German version of the HOOS demonstrated good psychometric properties. It proved to be valid, reliable and responsive to the changes instrument for use in patients with hip osteoarthritis undergoing total hip replacement.

  2. Accurate analysis and visualization of cardiac (11)C-PIB uptake in amyloidosis with semiautomatic software.

    PubMed

    Kero, Tanja; Lindsjö, Lars; Sörensen, Jens; Lubberink, Mark

    2016-08-01

    (11)C-PIB PET is a promising non-invasive diagnostic tool for cardiac amyloidosis. Semiautomatic analysis of PET data is now available but it is not known how accurate these methods are for amyloid imaging. The aim of this study was to evaluate the feasibility of one semiautomatic software tool for analysis and visualization of (11)C-PIB left ventricular retention index (RI) in cardiac amyloidosis. Patients with systemic amyloidosis and cardiac involvement (n = 10) and healthy controls (n = 5) were investigated with dynamic (11)C-PIB PET. Two observers analyzed the PET studies with semiautomatic software to calculate the left ventricular RI of (11)C-PIB and to create parametric images. The mean RI at 15-25 min from the semiautomatic analysis was compared with RI based on manual analysis and showed comparable values (0.056 vs 0.054 min(-1) for amyloidosis patients and 0.024 vs 0.025 min(-1) in healthy controls; P = .78) and the correlation was excellent (r = 0.98). Inter-reader reproducibility also was excellent (intraclass correlation coefficient, ICC > 0.98). Parametric polarmaps and histograms made visual separation of amyloidosis patients and healthy controls fast and simple. Accurate semiautomatic analysis of cardiac (11)C-PIB RI in amyloidosis patients is feasible. Parametric polarmaps and histograms make visual interpretation fast and simple.

  3. Translation and Validation of the Korean Version of the International Knee Documentation Committee Subjective Knee Form

    PubMed Central

    Kim, Jin Goo; Lee, Joong Yub; Seo, Seung Suk; Choi, Choong Hyeok; Lee, Myung Chul

    2013-01-01

    Purpose To perform a cross-cultural adaptation and to test the measurement properties of the Korean version of International Knee Documentation Committee (K-IKDC) Subjective Knee Form. Materials and Methods According to the guidelines for cross-cultural adaptation, translation and backward translation of the English version of the IKDC Subjective Knee Form were performed. After translation into the Korean version, 150 patients who had knee-related problems were asked to complete the K-IKDC, Lysholm score, and Short Form-36 (SF-36). Of these patients, 126 were retested 2 weeks later to evaluate test-retest reliability, and 104 were recruited 3 months later to evaluate responsiveness. Construct validity was analyzed by investigating the correlation with Lysholm score and SF-36; content validity was also evaluated. Standardized mean response was calculated for evaluating responsiveness. Results The test-retest reliability proved excellent with a high value for the intraclass correlation coefficient (r=0.94). The internal consistency was strong (Cronbach's α=0.91). Good content validity with absence of floor not ceiling effects and good convergent and divergent validity were observed. Moderate responsiveness was shown (standardized mean response=0.689). Conclusions The K-IKDC demonstrated good measurement properties. We suggest that this instrument is an excellent evaluation instrument that can be used for Korean patients with knee-related injuries. PMID:24032098

  4. Validation of the Chinese version of functional assessment of anorexia-cachexia therapy (FAACT) scale for measuring quality of life in cancer patients with cachexia.

    PubMed

    Zhou, Ting; Yang, Kaixiang; Thapa, Sudip; Fu, Qiang; Jiang, Yongsheng; Yu, Shiying

    2017-04-01

    The assessment of quality of life (QOL) is an important part of cachexia management for cancer patients. Functional assessment of anorexia-cachexia therapy (FAACT), a specific QOL instrument for cachexia patients, has not been validated in Chinese population. The aim of this study was to validate the FAACT scale in Chinese cancer patients for its future use. Eligible cancer patients were included in our study. Patients' demographic and clinical characteristics were collected from the electronic medical records. Patients were asked to complete the Chinese version of FAACT scale and the MD Anderson symptom inventory (MDASI), and then the reliability and validity were analyzed. A total of 285 patients were enrolled in our study, data of 241 patients were evaluated. Coefficients of Cronbach's alpha, test-retest and split-half analyses were all greater than 0.8, which indicated an excellent reliability for FAACT scale. In item-subscale correlation analysis and factor analysis, good construct validity for FAACT scale was found. The correlation between FAACT and MDASI interference subscale showed reasonable criterion-related validity, and for further clinical validation, the FAACT scale showed excellent discriminative validity for distinguishing patients in different cachexia status and in different performance status. The Chinese version of FAACT scale has good reliability and validity and is suitable for measuring QOL of cachexia patients in Chinese population.

  5. Arabic cross cultural adaptation and validation of the National Institutes of Health Stroke Scale.

    PubMed

    Hussein, Haitham M; Abdel Moneim, Amr; Emara, Tamer; Abd-Elhamid, Yousry A; Salem, Haitham H; Abd-Allah, Foad; Farrag, Mohammad A; Tork, M Amir; Shalash, Ali S; Ezz El Dein, Khaled H; Osman, Gamaleldin; Georgy, Shady S; Ghali, Peter G; Lyden, Patrick D; Moustafa, Ramez R

    2015-10-15

    The National Institutes of Health Stroke Scale (NIHSS), the most commonly used tool to quantify neurological deficit in acute stroke, was initially developed in English. We present our experience in developing and validating an Arabic version of the NIHSS (arNIHSS). In 6months, 137 patients were recruited (mean age±standard deviation 62±12years; 48 women). For interrater agreement, weighted kappa value ranged from 0.36 to 0.66 and intraclass correlation coefficient (ICC) for the whole scale was excellent at 0.95 (95% confidence interval [CI] 0.94-0.97). For intrarater agreement, weighted kappa ranged from 0.52 to 1.0 and the ICC was 0.94 (95% CI 0.87-0.98). The construct validity of the arNIHSS is demonstrated by its correlation with the DWI-ASPECT and the 3months mRS score (Spearman correlation -0.46 and 0.58 respectively; P<0.001 for both). We developed and validated a culturally adapted Arabic version of the NIHSS. Further validation in other Arab countries is recommended. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Awareness of disease in dementia: factor structure of the assessment scale of psychosocial impact of the diagnosis of dementia.

    PubMed

    Dourado, Marcia C N; Mograbi, Daniel C; Santos, Raquel L; Sousa, Maria Fernanda B; Nogueira, Marcela L; Belfort, Tatiana; Landeira-Fernandez, Jesus; Laks, Jerson

    2014-01-01

    Despite the growing understanding of the conceptual complexity of awareness, there currently exists no instrument for assessing different domains of awareness in dementia. In the current study, the psychometric properties of a multidimensional awareness scale, the Assessment Scale of Psychosocial Impact of the Diagnosis of Dementia (ASPIDD), are explored in a sample of 201 people with dementia and their family caregivers. Cronbach's alpha was high (α = 0.87), indicating excellent internal consistency. The mean of corrected item-total correlation coefficients was moderate. ASPIDD presented a four-factor solution with a well-defined structure: awareness of activities of daily living, cognitive functioning and health condition, emotional state, and social functioning and relationships. Functional disability was positively correlated with total ASPIDD, unawareness of activities of daily living, cognitive functioning, and with emotional state. Caregiver burden was correlated with total ASPIDD scores and unawareness of cognitive functioning. The results suggest that ASPIDD is indeed a multidimensional scale, providing a reliable measure of awareness of disease in dementia. Further studies should explore the risk factors associated with different dimensions of awareness in dementia.

  7. Association of academic performance of premedical students to satisfaction and engagement in a short training program: a cross sectional study presenting gender differences

    PubMed Central

    2014-01-01

    Background It is important that students have a high academic engagement and satisfaction in order to have good academic achievement. No study measures association of these elements in a short training program. This study aimed to measure the correlation between academic achievement, satisfaction and engagement dimensions in a short training program among premedical students. Methods We carried out a cross sectional study, in August 2013, at Cercle d’Etudiants, Ingénieurs, Médecins et Professeurs de Lycée pour le Triomphe de l’Excellence (CEMPLEX) training center, a center which prepares students for the national common entrance examination into medical schools in Cameroon. We included all students attending this training center during last examination period. They were asked to fill out a questionnaire on paper. Academic engagement was measured using three dimensions: vigor, dedication and absorption. Satisfaction to lessons, for each learning subject was collected. Academic achievement was calculated using mean of the score of all learning subjects affected with their coefficient. Pearson coefficient (r) and multiple regression models were used to measure association. A p value < 0.05 was statistically significant. Results In total, 180 students were analyzed. In univariate linear analysis, we found correlation with academic achievement for vigor (r = 0.338, p = 0.006) and dedication (r = 0.287, p = 0.021) only in male students. In multiple regression linear analysis, academic engagement and satisfaction were correlated to academic achievement only in male students (R2 = 0.159, p = 0.035). No correlation was found in female students and in all students. The independent variables (vigor, dedication, absorption and satisfaction) explained 6.8-24.3% of the variance of academic achievement. Conclusion It is only in male students that academic engagement and satisfaction to lessons are correlated to academic achievement in this short training program for premedical students and this correlation is weak. PMID:24564911

  8. Association of academic performance of premedical students to satisfaction and engagement in a short training program: a cross sectional study presenting gender differences.

    PubMed

    Bigna, Jean Joel R; Fonkoue, Loic; Tchatcho, Manuela Francette F; Dongmo, Christelle N; Soh, Dorothée M; Um, Joseph Lin Lewis N; Sime, Paule Sandra D; Affana, Landry A; Woum, Albert Ruben N; Noumegni, Steve Raoul N; Tabekou, Alphonce; Wanke, Arlette M; Taffe, Herman Rhais K; Tchoukouan, Miriette Linda N; Anyope, Kevin O; Ella, Stephane Brice E; Mouaha, Berny Vanessa T; Kenne, Edgar Y; Mbessoh, Ulrich Igor K; Tchapmi, Adrienne Y; Tene, Donald F; Voufouo, Steve S; Zogo, Stephanie M; Nouebissi, Linda P; Satcho, Kevine F; Tchoumo, Wati Joel T; Basso, Moise Fabrice; Tcheutchoua, Bertrand Daryl N; Agbor, Ako A

    2014-02-24

    It is important that students have a high academic engagement and satisfaction in order to have good academic achievement. No study measures association of these elements in a short training program. This study aimed to measure the correlation between academic achievement, satisfaction and engagement dimensions in a short training program among premedical students. We carried out a cross sectional study, in August 2013, at Cercle d'Etudiants, Ingénieurs, Médecins et Professeurs de Lycée pour le Triomphe de l'Excellence (CEMPLEX) training center, a center which prepares students for the national common entrance examination into medical schools in Cameroon. We included all students attending this training center during last examination period. They were asked to fill out a questionnaire on paper. Academic engagement was measured using three dimensions: vigor, dedication and absorption. Satisfaction to lessons, for each learning subject was collected. Academic achievement was calculated using mean of the score of all learning subjects affected with their coefficient. Pearson coefficient (r) and multiple regression models were used to measure association. A p value < 0.05 was statistically significant. In total, 180 students were analyzed. In univariate linear analysis, we found correlation with academic achievement for vigor (r = 0.338, p = 0.006) and dedication (r = 0.287, p = 0.021) only in male students. In multiple regression linear analysis, academic engagement and satisfaction were correlated to academic achievement only in male students (R2 = 0.159, p = 0.035). No correlation was found in female students and in all students. The independent variables (vigor, dedication, absorption and satisfaction) explained 6.8-24.3% of the variance of academic achievement. It is only in male students that academic engagement and satisfaction to lessons are correlated to academic achievement in this short training program for premedical students and this correlation is weak.

  9. Limited Sampling Strategy for the Prediction of Area Under the Curve (AUC) of Statins: Reliability of a Single Time Point for AUC Prediction for Pravastatin and Simvastatin.

    PubMed

    Srinivas, N R

    2016-02-01

    Statins are widely prescribed medicines and are also available in fixed dose combinations with other drugs to treat several chronic ailments. Given the safety issues associated with statins it may be important to assess feasibility of a single time concentration strategy for prediction of exposure (area under the curve; AUC). The peak concentration (Cmax) was used to establish relationship with AUC separately for pravastatin and simvastatin using published pharmacokinetic data. The regression equations generated for statins were used to predict the AUC values from various literature references. The fold difference of the observed divided by predicted values along with correlation coefficient (r) were used to judge the feasibility of the single time point approach. Both pravastatin and simvastatin showed excellent correlation of Cmax vs. AUC values with r value ≥ 0.9638 (p<0.001). The fold difference was within 0.5-fold to 2-fold for 220 out of 227 AUC predictions and >81% of the predicted values were in a narrower range of >0.75-fold but <1.5-fold difference. Predicted vs. observed AUC values showed excellent correlation for pravastatin (r=0.9708, n=115; p<0.001) and simvastatin (r=0.9810; n=117; p<0.001) suggesting the utility of Cmax for AUC predictions. On the basis of the present work, it is feasible to develop a single concentration time point strategy that coincides with Cmax occurrence for both pravastatin and simvastatin from a therapeutic drug monitoring perspective. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Correlation of PET and AMS analyses for early kinetics of 2-fluoro-2-deoxyglucose (FDG)

    NASA Astrophysics Data System (ADS)

    Minamimoto, Ryogo; Hamabe, Yoshimi; Miyaoka, Teiji; Theeraladanon, Chumpol; Oka, Takashi; Matsui, Takao; Inoue, Tomio

    2010-04-01

    The draft of the guidelines for microdosing in clinical trials was published in Japan in 2008 following the guidelines of the European Medicines Agency (EMEA) and the Food and Drug Administration (FDA). It recommends utilizing accelerator mass spectrometry (AMS), liquid chromatography/mass spectrometry (LC/MS/MS), and positron emission tomography (PET) for monitoring drug metabolites in preclinical studies. In this study, we clarified the correlation in measuring result between PET and AMS. The AMS measurement was undergone by using AMS system of Institute of Accelerator Analysis Ltd. (IAA, Kawasaki, Japan). First the back ground 14C level of blood in mice was measured by AMS. Second, we clarified the relationship between AMS and PET by using 2-fluoro-2-deoxyglucose (FDG). The correlation coefficient ( r) of the measurements using PET ( 18F-FDG) and AMS ( 14C-FDG) were quite high at 0.97 ( Y = 7.54 E - 05 X + 0.02, p < 0.001). The blood clearance profile of 18F-FDG was nearly identical with that of 14C-FDG. These results indicate that the AMS analysis has excellent correlation with the PET method.

  11. Adaptation, reliability and validity testing of a Persian version of the Health Assessment Questionnaire-Disability Index in Iranian patients with rheumatoid arthritis.

    PubMed

    Nazary-Moghadam, Salman; Zeinalzadeh, Afsaneh; Salavati, Mahyar; Almasi, Simin; Negahban, Hossein

    2017-01-01

    The aim of the present study was to culturally adapt and evaluate reliability and validity of Health Assessment Questionnaire-Disability Index (HAQ-DI) in Iranian patients with rheumatoid arthritis (RA). 234 patients with RA for validation study, Eighty-six participants for reliability study. Test-retest relative reliability and internal consistency of Persian version of HAQ-DI were examined by intraclass correlation coefficient (ICC) and Cronbach's alpha, respectively. Additionally, HAQ-DI construct validity (Spearman's correlation) was examined using Persian version of Short-Form 36 Health survey (SF-36), activity and severity parameters. Persian version of HAQ-DI total score showed excellent test-retest reliability (ICC = 0.98) and internal consistency (Cronbach's alpha = 0.95). Spearman's correlations between the total PHAQ-DI score and activity and severity parameters were above 0.55. Correlation between PHAQ-DI and SF-36 Physical Health were higher as compared with SF-36 Mental Health. Persian version of HAQ-DI is a reliable and valid culturally-adapted instrument in order to measure functional limitations in Iranian people with RA. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. An evaluation of Brix refractometry instruments for measurement of colostrum quality in dairy cattle.

    PubMed

    Bielmann, V; Gillan, J; Perkins, N R; Skidmore, A L; Godden, S; Leslie, K E

    2010-08-01

    Acquisition of high quality colostrum is an important factor influencing neonatal calf health. Many methods have been used to assess the Ig concentration of colostrum; however, improved, validated evaluation tools are needed. The aims of this study were to evaluate both optical and digital Brix refractometer instruments for the measurement of Ig concentration of colostrum as compared with the gold standard radial immunodiffusion assay laboratory assessment and to determine the correlation between Ig measurements taken from fresh and frozen colostrum samples for both Brix refractometer instruments. This research was completed using 288 colostrum samples from 3 different farms. It was concluded that the optical and digital Brix refractometers were highly correlated for both fresh and frozen samples (r=0.98 and r=0.97, respectively). Correlation between both refractometer instruments for fresh and frozen samples and the gold standard radial immunodiffusion assay were determined to be very similar, with a correlation coefficient between 0.71 and 0.74. Both instruments exhibited excellent test characteristics, indicating an appropriate cut-off point of 22% Brix score for the identification of good quality colostrum. Copyright (c) 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  13. The reliability of four widely used patellar height ratios.

    PubMed

    van Duijvenbode, Dennis; Stavenuiter, Michel; Burger, Bart; van Dijke, Cees; Spermon, Jacco; Hoozemans, Marco

    2016-03-01

    The objective of this study was to evaluate the inter-observer reliability and the intra-observer reliability of four patellar height ratios: Insall-Salvati (IS), modified Insall-Salvati (MIS), Blackburne-Peel (BP) and Caton-Deschamps (CD). The patellar height ratios were assessed by four independent examiners using weight-bearing lateral knee radiographs in 30° flexion. Intra-class correlation coefficients and Fleiss' kappa's were determined. The inter-observer reliability was excellent for the IS and moderate for the other ratios. When the ratio values were categorized, the inter-observer reliability was strong for the IS, moderate for the MIS and BP, and poor for the CD. The intra-observer reliability was excellent for the IS, MIS and CD, and strong for the BP. When the ratio values were categorized, the intra-observer reliability was strong for the IS and MIS, and moderate for the other ratios. Although the IS showed best reliability, we advise to use the MIS as it showed the second best reliability but is, according to the literature, associated with better validity.

  14. Rater reliability and concurrent validity of the Keyboard Personal Computer Style instrument (K-PeCS).

    PubMed

    Baker, Nancy A; Cook, James R; Redfern, Mark S

    2009-01-01

    This paper describes the inter-rater and intra-rater reliability, and the concurrent validity of an observational instrument, the Keyboard Personal Computer Style instrument (K-PeCS), which assesses stereotypical postures and movements associated with computer keyboard use. Three trained raters independently rated the video clips of 45 computer keyboard users to ascertain inter-rater reliability, and then re-rated a sub-sample of 15 video clips to ascertain intra-rater reliability. Concurrent validity was assessed by comparing the ratings obtained using the K-PeCS to scores developed from a 3D motion analysis system. The overall K-PeCS had excellent reliability [inter-rater: intra-class correlation coefficients (ICC)=.90; intra-rater: ICC=.92]. Most individual items on the K-PeCS had from good to excellent reliability, although six items fell below ICC=.75. Those K-PeCS items that were assessed for concurrent validity compared favorably to the motion analysis data for all but two items. These results suggest that most items on the K-PeCS can be used to reliably document computer keyboarding style.

  15. Psychometric Evaluation of the Revised Michigan Diabetes Knowledge Test (V.2016) in Arabic: Translation and Validation

    PubMed Central

    Alhaiti, Ali Hassan; Alotaibi, Alanod Raffa; Jones, Linda Katherine; DaCosta, Cliff

    2016-01-01

    Objective. To translate the revised Michigan Diabetes Knowledge Test into the Arabic language and examine its psychometric properties. Setting. Of the 139 participants recruited through King Fahad Medical City in Riyadh, Saudi Arabia, 34 agreed to the second-round sample for retesting purposes. Methods. The translation process followed the World Health Organization's guidelines for the translation and adaptation of instruments. All translations were examined for their validity and reliability. Results. The translation process revealed excellent results throughout all stages. The Arabic version received 0.75 for internal consistency via Cronbach's alpha test and excellent outcomes in terms of the test-retest reliability of the instrument with a mean of 0.90 infraclass correlation coefficient. It also received positive content validity index scores. The item-level content validity index for all instrument scales fell between 0.83 and 1 with a mean scale-level index of 0.96. Conclusion. The Arabic version is proven to be a reliable and valid measure of patient's knowledge that is ready to be used in clinical practices. PMID:27995149

  16. Polyaniline-graphene oxide nanocomposite sensor for quantification of calcium channel blocker levamlodipine.

    PubMed

    Jain, Rajeev; Sinha, Ankita; Khan, Ab Lateef

    2016-08-01

    A novel polyaniline-graphene oxide nanocomposite (PANI/GO/GCE) sensor has been fabricated for quantification of a calcium channel blocker drug levamlodipine (LAMP). Fabricated sensor has been characterized by electrochemical impedance spectroscopy, square wave and cyclic voltammetry, Raman spectroscopy and Fourier transform infrared (FTIR) spectroscopy. The developed PANI/GO/GCE sensor has excellent analytical performance towards electrocatalytic oxidation as compared to PANI/GCE, GO/GCE and bare GCE. Under optimized experimental conditions, the fabricated sensor exhibits a linear response for LAMP for its oxidation over a concentration range from 1.25μgmL(-1) to 13.25μgmL(-1) with correlation coefficient of 0.9950 (r(2)), detection limit of 1.07ngmL(-1) and quantification limit of 3.57ngmL(-1). The sensor shows an excellent performance for detecting LAMP with reproducibility of 2.78% relative standard deviation (RSD). The proposed method has been successfully applied for LAMP determination in pharmaceutical formulation with a recovery from 99.88% to 101.75%. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. The development and evaluation of a novel repurposing of a peripheral gaming device for the acquisition of forces applied to a hydraulic treatment plinth.

    PubMed

    Cooper, Darren; Bevins, Joe; Corbett, Mark

    2018-01-13

    This technical note details the stages taken to create an instrumented hydraulic treatment plinth for the measurement of applied forces in the vertical axis. The modification used a widely available low-cost peripheral gaming device and required only basic construction and computer skills. The instrumented treatment plinth was validated against a laboratory grade force platform across a range of applied masses from 0.5-15 kg, mock Gr I-IV vertebral mobilisations and a dynamic response test. Intraclass correlation coefficients demonstrated poor reliability (0.46) for low masses of 0.5 kg improving to excellent for larger masses up to15 kg respectively; excellent to good reliability (0.97-0.86) for the mock mobilisations and moderate reliability (0.51) for the dynamic response test. The study demonstrates how a cheap peripheral gaming device can be repurposed so that forces applied to a hydraulic treatment plinth can be collected reliably when applied in a clinically reasoned manner. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Gaussian graphical modeling reveals specific lipid correlations in glioblastoma cells

    NASA Astrophysics Data System (ADS)

    Mueller, Nikola S.; Krumsiek, Jan; Theis, Fabian J.; Böhm, Christian; Meyer-Bäse, Anke

    2011-06-01

    Advances in high-throughput measurements of biological specimens necessitate the development of biologically driven computational techniques. To understand the molecular level of many human diseases, such as cancer, lipid quantifications have been shown to offer an excellent opportunity to reveal disease-specific regulations. The data analysis of the cell lipidome, however, remains a challenging task and cannot be accomplished solely based on intuitive reasoning. We have developed a method to identify a lipid correlation network which is entirely disease-specific. A powerful method to correlate experimentally measured lipid levels across the various samples is a Gaussian Graphical Model (GGM), which is based on partial correlation coefficients. In contrast to regular Pearson correlations, partial correlations aim to identify only direct correlations while eliminating indirect associations. Conventional GGM calculations on the entire dataset can, however, not provide information on whether a correlation is truly disease-specific with respect to the disease samples and not a correlation of control samples. Thus, we implemented a novel differential GGM approach unraveling only the disease-specific correlations, and applied it to the lipidome of immortal Glioblastoma tumor cells. A large set of lipid species were measured by mass spectrometry in order to evaluate lipid remodeling as a result to a combination of perturbation of cells inducing programmed cell death, while the other perturbations served solely as biological controls. With the differential GGM, we were able to reveal Glioblastoma-specific lipid correlations to advance biomedical research on novel gene therapies.

  19. Reliability and Validity of Isometric Knee Extensor Strength Test With Hand-Held Dynamometer Depending on Its Fixation: A Pilot Study

    PubMed Central

    Kim, Won Kuel; Seo, Kyung Mook; Kang, Si Hyun

    2014-01-01

    Objective To determine the reliability and validity of hand-held dynamometer (HHD) depending on its fixation in measuring isometric knee extensor strength by comparing the results with an isokinetic dynamometer. Methods Twenty-seven healthy female volunteers participated in this study. The subjects were tested in seated and supine position using three measurement methods: isometric knee extension by isokinetic dynamometer, non-fixed HHD, and fixed HHD. During the measurement, the knee joints of subjects were fixed at a 35° angle from the extended position. The fixed HHD measurement was conducted with the HHD fixed to distal tibia with a Velcro strap; non-fixed HHD was performed with a hand-held method without Velcro fixation. All the measurements were repeated three times and among them, the maximum values of peak torque were used for the analysis. Results The data from the fixed HHD method showed higher validity than the non-fixed method compared with the results of the isokinetic dynamometer. Pearson correlation coefficients (r) between fixed HHD and isokinetic dynamometer method were statistically significant (supine-right: r=0.806, p<0.05; seating-right: r=0.473, p<0.05; supine-left: r=0.524, p<0.05), whereas Pearson correlation coefficients between non-fixed dynamometer and isokinetic dynamometer methods were not statistically significant, except for the result of the supine position of the left leg (r=0.384, p<0.05). Both fixed and non-fixed HHD methods showed excellent inter-rater reliability. However, the fixed HHD method showed a higher reliability than the non-fixed HHD method by considering the intraclass correlation coefficient (fixed HHD, 0.952-0.984; non-fixed HHD, 0.940-0.963). Conclusion Fixation of HHD during measurement in the supine position increases the reliability and validity in measuring the quadriceps strength. PMID:24639931

  20. NovoTTF™-100A System (Tumor Treating Fields) transducer array layout planning for glioblastoma: a NovoTAL™ system user study.

    PubMed

    Chaudhry, Aafia; Benson, Laura; Varshaver, Michael; Farber, Ori; Weinberg, Uri; Kirson, Eilon; Palti, Yoram

    2015-11-11

    Optune™, previously known as the NovoTTF-100A System™, generates Tumor Treating Fields (TTFields), an effective anti-mitotic therapy for glioblastoma. The system delivers intermediate frequency, alternating electric fields to the supratentorial brain. Patient therapy is personalized by configuring transducer array layout placement on the scalp to the tumor site using MRI measurements and the NovoTAL System. Transducer array layout mapping optimizes therapy by maximizing electric field intensity to the tumor site. This study evaluated physician performance in conducting transducer array layout mapping using the NovoTAL System compared with mapping performed by the Novocure in-house clinical team. Fourteen physicians (7 neuro-oncologists, 4 medical oncologists, and 3 neurosurgeons) evaluated five blinded cases of recurrent glioblastoma and performed head size and tumor location measurements using a standard Digital Imaging and Communications in Medicine reader. Concordance with Novocure measurement and intra- and inter-rater reliability were assessed using relevant correlation coefficients. The study criterion for success was a concordance correlation coefficient (CCC) >0.80. CCC for each physician versus Novocure on 20 MRI measurements was 0.96 (standard deviation, SD ± 0.03, range 0.90-1.00), indicating very high agreement between the two groups. Intra- and inter-rater reliability correlation coefficients were similarly high: 0.83 (SD ±0.15, range 0.54-1.00) and 0.80 (SD ±0.18, range 0.48-1.00), respectively. This user study demonstrated an excellent level of concordance between prescribing physicians and Novocure in-house clinical teams in performing transducer array layout planning. Intra-rater reliability was very high, indicating reproducible performance. Physicians prescribing TTFields, when trained on the NovoTAL System, can independently perform transducer array layout mapping required for the initiation and maintenance of patients on TTFields therapy.

  1. Psychometric study of the Required Care Levels for People with Severe Mental Disorder Assessment Scale (ENAR-TMG).

    PubMed

    Lascorz, David; López, Victoria; Pinedo, Carmen; Trujols, Joan; Vegué, Joan; Pérez, Víctor

    2016-03-08

    People with severe mental disorder have significant difficulties in everyday life that involve the need for continued support. These needs are not easily measurable with the currently available tools. Therefore, a multidimensional scale that assesses the different levels of need for care is proposed, including a study of its psychometric properties. One-hundred and thirty-nine patients (58% men) with a severe mental disorder were assessed using the Required Care Levels for People with Severe Mental Disorder Assessment Scale (ENAR-TMG), the Camberwell Assessment of Need scale, and the Health of the Nation Outcome Scales. ENAR-TMG's psychometric features were examined by: a) evaluating 2 sources of validity evidence (evidence based on internal structure and evidence based on relations to other variables), and b) estimating the internal consistency, temporal stability, inter-rater reliability, and sensitivity to change of scores of the ENAR-TMG's subscales. Exploratory factor analyses revealed a one-factor structure for each of the theoretical dimensions of the scale, in which all but one showed a significant and positive correlation with the Camberwell Assessment of Need (range of r: 0.143-0.557) and Health of the Nation Outcome Scales (range of r: 0.241-0.474) scales. ENAR-TMG subscale scores showed acceptable internal consistency (range of ordinal α coefficients: 0.682-0.804), excellent test-retest (range of intraclass correlation coefficients: 0.889-0.999) and inter-rater reliabilities (range of intraclass correlation coefficients: 0.926-0.972), and satisfactory sensitivity to treatment-related changes (range of η 2 : 0.003-0.103). The satisfactory psychometric behaviour of the ENAR-TMG makes the scale a promising tool to assess global functioning in people with a severe mental disorder. Copyright © 2016 SEP y SEPB. Published by Elsevier España. All rights reserved.

  2. Monitoring of cyclosporine concentrations by using dry blood-spot samples.

    PubMed

    Mee, A V; Wong, P Y; Sun, C; Oei, L; Elliott, S; Naik, N; Joaquin, B; Uchimaru, D

    1991-01-01

    We modified the Incstar Cyclo Trac SP kit to enable its use with dry blood-spots on filter paper. The recovery ranged from 92 to 106%. Dilution studies have shown excellent linearity and parallelism throughout the range of the assay. Precision is demonstrated by within-assay CV's of 6.6 and 4.3% at 96 and 342 micrograms/L respectively and between-assay CV's of 9.1 and 7.0% at 138 and 506 micrograms/L respectively. A comparison study (n = 209) with whole blood assay gave a correlation coefficient of 0.97, a slope of 1.04, and an intercept of 13.2. Whole blood and dry blood-spot cyclosporine assays on heart, kidney, liver, and lung transplants were also compared.

  3. Factors That Attenuate the Correlation Coefficient and Its Analogs.

    ERIC Educational Resources Information Center

    Dolenz, Beverly

    The correlation coefficient is an integral part of many other statistical techniques (analysis of variance, t-tests, etc.), since all analytic methods are actually correlational (G. V. Glass and K. D. Hopkins, 1984). The correlation coefficient is a statistical summary that represents the degree and direction of relationship between two variables.…

  4. Three-dimensional ultrasonography of the breast; An adequate replacement for MRI in neoadjuvant chemotherapy tumour response evaluation? - RESPONDER trial.

    PubMed

    van Egdom, L S E; Lagendijk, M; Heijkoop, E H M; Koning, A H J; van Deurzen, C H M; Jager, A; van Lankeren, W; Koppert, L B

    2018-07-01

    Accurate measurement of tumour response during and after neoadjuvant chemotherapy (NAC) is important and may influence treatment decisions in invasive breast cancer patients. Breast MRI forms the gold standard but is more burdensome, time consuming and costly. In this study response measurement was done with 3-D ultrasound by Automated Breast Volume Scanner (ABVS) and compared to breast MRI. Moreover, patient satisfaction with both techniques was compared. A single-institution, prospective observational pilot study evaluating tumour response by ABVS in addition to breast MRI (standard care) was performed in 25 invasive breast cancer patients receiving NAC. Tumour response was evaluated comparing longest tumour diameters as well as tumour volumes at predefined time points using Bland-Altman analysis. Volume measurements for breast MRI were obtained using a fully immersive virtual reality system (a Barco I-Space) and V-Scope software. Same software was used to obtain ABVS volume measurements using an in-house developed desktop VR system. Inter- and intra-observer agreement was evaluated by Intraclass Correlation Coefficient (ICC). Twenty-five patients were eligible for baseline measurement, 20 for a mid-NAC response evaluation, and five for a post-NAC response evaluation. MRI and ABVS showed absolute concordance in 73% of patients for the mid-NAC evaluation, with a 'good' correlation for the difference in longest diameter measurement (ICC 0.73, p < 0.01) as compared to baseline assessment. Concerning difference in volume measurement in the mid-NAC response evaluation showed a 'fair' correlation (ICC 0.52, p < 0.01) and in the post-NAC response evaluation an 'excellent' correlation (ICC 0.98, p < 0.01). 'Excellent' inter- and intra-observer agreement was found (ICC 0.88, p < 0.01) with comparable limits of agreement (LOA) for observer 1 and 2 in both diameter and volume measurement. Patient satisfaction was higher for ABVS compared to breast MRI, 93% versus 12% respectively. ABVS showed 'good' correlation with MRI tumour response evaluation in breast cancer patients during NAC with 'excellent' inter- and intra-observer agreement. ABVS has patients' preference over breast MRI and could be considered as alternative to breast MRI, in case results on an on-going prospective trial confirm these results (NTR6799). Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Whole-Lesion Apparent Diffusion Coefficient-Based Entropy-Related Parameters for Characterizing Cervical Cancers: Initial Findings.

    PubMed

    Guan, Yue; Li, Weifeng; Jiang, Zhuoran; Chen, Ying; Liu, Song; He, Jian; Zhou, Zhengyang; Ge, Yun

    2016-12-01

    This study aimed to develop whole-lesion apparent diffusion coefficient (ADC)-based entropy-related parameters of cervical cancer to preliminarily assess intratumoral heterogeneity of this lesion in comparison to adjacent normal cervical tissues. A total of 51 women (mean age, 49 years) with cervical cancers confirmed by biopsy underwent 3-T pelvic diffusion-weighted magnetic resonance imaging with b values of 0 and 800 s/mm 2 prospectively. ADC-based entropy-related parameters including first-order entropy and second-order entropies were derived from the whole tumor volume as well as adjacent normal cervical tissues. Intraclass correlation coefficient, Wilcoxon test with Bonferroni correction, Kruskal-Wallis test, and receiver operating characteristic curve were used for statistical analysis. All the parameters showed excellent interobserver agreement (all intraclass correlation coefficients  > 0.900). Entropy, entropy(H) 0 , entropy(H) 45 , entropy(H) 90 , entropy(H) 135 , and entropy(H) mean were significantly higher, whereas entropy(H) range and entropy(H) std were significantly lower in cervical cancers compared to adjacent normal cervical tissues (all P <.0001). Kruskal-Wallis test showed that there were no significant differences among the values of various second-order entropies including entropy(H) 0, entropy(H) 45 , entropy(H) 90 , entropy(H) 135 , and entropy(H) mean. All second-order entropies had larger area under the receiver operating characteristic curve than first-order entropy in differentiating cervical cancers from adjacent normal cervical tissues. Further, entropy(H) 45 , entropy(H) 90 , entropy(H) 135 , and entropy(H) mean had the same largest area under the receiver operating characteristic curve of 0.867. Whole-lesion ADC-based entropy-related parameters of cervical cancers were developed successfully, which showed initial potential in characterizing intratumoral heterogeneity in comparison to adjacent normal cervical tissues. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  6. Relative Validity and Reproducibility of an Interviewer Administered 14-Item FFQ to Estimate Flavonoid Intake Among Older Adults with Mild-Moderate Dementia.

    PubMed

    Kent, Katherine; Charlton, Karen

    2017-01-01

    There is a large burden on researchers and participants when attempting to accurately measure dietary flavonoid intake using dietary assessment. Minimizing participant and researcher burden when collecting dietary data may improve the validity of the results, especially in older adults with cognitive impairment. A short 14-item food frequency questionnaire (FFQ) to measure flavonoid intake, and flavonoid subclasses (anthocyanins, flavan-3-ols, flavones, flavonols, and flavanones) was developed and assessed for validity and reproducibility against a 24-hour recall. Older adults with mild-moderate dementia (n = 49) attended two interviews 12 weeks apart. With the assistance of a family carer, a 24-h recall was collected at the first interview, and the flavonoid FFQ was interviewer-administered at both time-points. Validity and reproducibility was assessed using the Wilcoxon signed-rank sum test, Spearman's correlation coefficient, Bland-Altman Plots, and Cohen's kappa. Mean flavonoid intake was determined (FFQ1 = 795 ± 492.7 mg/day, 24-h recall = 515.6 ± 384.3 mg/day). Tests of validity indicated the FFQ was better at estimating total flavonoid intake than individual flavonoid subclasses compared with the 24-h recall. There was a significant difference in total flavonoid intake estimates between the FFQ and the 24-h recall (Wilcoxon signed-rank sum p < 0.001; Bland-Altman plots indicated large bias and wide limits of agreement), but they were well correlated (Spearman's correlation coefficient r = 0.74, p < 0.001; Cohen's kappa κ = 0.292, p < 0.001). The FFQ showed good reproducibility, with a small mean percentage difference (12.6%). The Wilcoxon signed-rank sum test showed no significant difference, Spearman's correlation coefficient indicated excellent reliability (r = 0.75, p < 0.001), Bland-Altman plots visually showed small, nonsignificant bias and wide limits of agreement, and Cohen's kappa indicated fair agreement (κ = 0.429, p < 0.001). A 14-item FFQ developed to easily measure flavonoid intake in older adults with dementia demonstrates fair validity against a 24-h recall and good reproducibility.

  7. Quantification of hand synovitis in rheumatoid arthritis: Arterial mask subtraction reinforced with mutual information can improve accuracy of pixel-by-pixel time-intensity curve shape analysis in dynamic MRI.

    PubMed

    Kobayashi, Yuto; Kamishima, Tamotsu; Sugimori, Hiroyuki; Ichikawa, Shota; Noguchi, Atsushi; Kono, Michihito; Iiyama, Toshitake; Sutherland, Kenneth; Atsumi, Tatsuya

    2018-03-01

    Synovitis, which is a hallmark of rheumatoid arthritis (RA), needs to be precisely quantified to determine the treatment plan. Time-intensity curve (TIC) shape analysis is an objective assessment method for characterizing the pixels as artery, inflamed synovium, or other tissues using dynamic contrast-enhanced MRI (DCE-MRI). To assess the feasibility of our original arterial mask subtraction method (AMSM) with mutual information (MI) for quantification of synovitis in RA. Prospective study. Ten RA patients (nine women and one man; mean age, 56.8 years; range, 38-67 years). 3T/DCE-MRI. After optimization of TIC shape analysis to the hand region, a combination of TIC shape analysis and AMSM was applied to synovial quantification. The MI between pre- and postcontrast images was utilized to determine the arterial mask phase objectively, which was compared with human subjective selection. The volume of objectively measured synovitis by software was compared with that of manual outlining by an experienced radiologist. Simple TIC shape analysis and TIC shape analysis combined with AMSM were compared in slices without synovitis according to subjective evaluation. Pearson's correlation coefficient, paired t-test and intraclass correlation coefficient (ICC). TIC shape analysis was successfully optimized in the hand region with a correlation coefficient of 0.725 (P < 0.01) with the results of manual assessment regarded as ground truth. Objective selection utilizing MI had substantial agreement (ICC = 0.734) with subjective selection. Correlation of synovial volumetry in combination with TIC shape analysis and AMSM with manual assessment was excellent (r = 0.922, P < 0.01). In addition, negative predictive ability in slices without synovitis pixels was significantly increased (P < 0.01). The combination of TIC shape analysis and image subtraction reinforced with MI can accurately quantify synovitis of RA in the hand by eliminating arterial pixels. 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  8. Design and Reproducibility of a Mini-Survey to Evaluate the Quality of Food Intake (Mini-ECCA) in a Mexican Population

    PubMed Central

    González-Gómez, Montserrat; Orozco-Gutiérrez, Jaime Fernando; Prado-Arriaga, Ruth Jackelyne; Márquez-Sandoval, Fabiola; Altamirano-Martínez, Martha Betzaida

    2018-01-01

    Evaluating food intake quality may contribute to the development of nutrition programs. In Mexico, there are no screening tools that can be administered quickly for the evaluation of this variable. The aim was to determine the reproducibility of a mini-survey designed to evaluate the quality of food intake (Mini-ECCA) in a Mexican population. Mini-ECCA consists of 12 questions that are based on Mexican and international recommendations for food and non-alcoholic beverage intake, with the support of photographs for food quantity estimation. Each question scores as 0 (unhealthy) or 1 (healthy), and the final score undergoes a classification procedure. Through the framework of a nutritional study, 152 employees of the municipal water company in Guadalajara, Mexico (April–August 2016), were invited to participate. The survey was administered in two rounds (test and retest) with a 15-day interval between them. We calculated the Spearman correlation coefficient, the intra-class correlation coefficient (ICC), and weighted kappa for score classification agreement (SPSS versus 14 p < 0.05 was considered statistically significant). The survey obtained a “good” reproducibility (ρ = 0.713, p < 0.001), and an excellent concordance (ICC = 0.841 Confidence Interval 95% 0.779, 0.885). It can thus be said that the Mini-ECCA displayed acceptable reproducibility and is suitable for the purpose of dietary assessment and guidance. PMID:29690618

  9. Design and Reproducibility of a Mini-Survey to Evaluate the Quality of Food Intake (Mini-ECCA) in a Mexican Population.

    PubMed

    Bernal-Orozco, María Fernanda; Badillo-Camacho, Nayeli; Macedo-Ojeda, Gabriela; González-Gómez, Montserrat; Orozco-Gutiérrez, Jaime Fernando; Prado-Arriaga, Ruth Jackelyne; Márquez-Sandoval, Fabiola; Altamirano-Martínez, Martha Betzaida; Vizmanos, Barbara

    2018-04-23

    Evaluating food intake quality may contribute to the development of nutrition programs. In Mexico, there are no screening tools that can be administered quickly for the evaluation of this variable. The aim was to determine the reproducibility of a mini-survey designed to evaluate the quality of food intake (Mini-ECCA) in a Mexican population. Mini-ECCA consists of 12 questions that are based on Mexican and international recommendations for food and non-alcoholic beverage intake, with the support of photographs for food quantity estimation. Each question scores as 0 (unhealthy) or 1 (healthy), and the final score undergoes a classification procedure. Through the framework of a nutritional study, 152 employees of the municipal water company in Guadalajara, Mexico (April⁻August 2016), were invited to participate. The survey was administered in two rounds (test and retest) with a 15-day interval between them. We calculated the Spearman correlation coefficient, the intra-class correlation coefficient (ICC), and weighted kappa for score classification agreement (SPSS versus 14 p < 0.05 was considered statistically significant). The survey obtained a “good” reproducibility (ρ = 0.713, p < 0.001), and an excellent concordance (ICC = 0.841 Confidence Interval 95% 0.779, 0.885). It can thus be said that the Mini-ECCA displayed acceptable reproducibility and is suitable for the purpose of dietary assessment and guidance.

  10. Reliability and Accuracy of Static Parameters Obtained From Ink and Pressure Platform Footprints.

    PubMed

    Zuil-Escobar, Juan Carlos; Martínez-Cepa, Carmen Belén; Martín-Urrialde, Jose Antonio; Gómez-Conesa, Antonia

    2016-09-01

    The purpose of this study was to evaluate the accuracy and the intrarater reliability of arch angle (AA), Staheli Index (SI), and Chippaux-Smirak Index (CSI) obtained from ink and pressure platform footprints. We obtained AA, SI, and CSI measurements from ink pedigraph footprints and pressure platform footprints in 40 healthy participants (aged 25.65 ± 5.187 years). Intrarater reliability was calculated for all parameters obtained using the 2 methods. Standard error of measurement and minimal detectable change were also calculated. A repeated-measure analysis of variance was used to identify differences between ink and pressure platform footprints. Intraclass correlation coefficient and Bland and Altman plots were used to assess similar parameters obtained using different methods. Intrarater reliability was >0.9 for all parameters and was slightly higher for the ink footprints. No statistical difference was reported in repeated-measure analysis of variance for any of the parameters. Intraclass correlation coefficient values from AA, SI, and CSI that were obtained using ink footprints and pressure platform footprints were excellent, ranging from 0.797 to 0.829. However, pressure platform overestimated AA and underestimated SI and CSI. Our study revealed that AA, SI, and CSI were similar regardless of whether the ink or pressure platform method was used. In addition, the parameters indicated high intrarater reliability and were reproducible. Copyright © 2016. Published by Elsevier Inc.

  11. External Validation of a Case-Mix Adjustment Model for the Standardized Reporting of 30-Day Stroke Mortality Rates in China.

    PubMed

    Yu, Ping; Pan, Yuesong; Wang, Yongjun; Wang, Xianwei; Liu, Liping; Ji, Ruijun; Meng, Xia; Jing, Jing; Tong, Xu; Guo, Li; Wang, Yilong

    2016-01-01

    A case-mix adjustment model has been developed and externally validated, demonstrating promise. However, the model has not been thoroughly tested among populations in China. In our study, we evaluated the performance of the model in Chinese patients with acute stroke. The case-mix adjustment model A includes items on age, presence of atrial fibrillation on admission, National Institutes of Health Stroke Severity Scale (NIHSS) score on admission, and stroke type. Model B is similar to Model A but includes only the consciousness component of the NIHSS score. Both model A and B were evaluated to predict 30-day mortality rates in 13,948 patients with acute stroke from the China National Stroke Registry. The discrimination of the models was quantified by c-statistic. Calibration was assessed using Pearson's correlation coefficient. The c-statistic of model A in our external validation cohort was 0.80 (95% confidence interval, 0.79-0.82), and the c-statistic of model B was 0.82 (95% confidence interval, 0.81-0.84). Excellent calibration was reported in the two models with Pearson's correlation coefficient (0.892 for model A, p<0.001; 0.927 for model B, p = 0.008). The case-mix adjustment model could be used to effectively predict 30-day mortality rates in Chinese patients with acute stroke.

  12. Study of Vis/NIR spectroscopy measurement on acidity of yogurt

    NASA Astrophysics Data System (ADS)

    He, Yong; Feng, Shuijuan; Wu, Di; Li, Xiaoli

    2006-09-01

    A fast measurement of pH of yogurt using Vis/NIR-spectroscopy techniques was established in order to measuring the acidity of yogurt rapidly. 27 samples selected separately from five different brands of yogurt were measured by Vis/NIR-spectroscopy. The pH of yogurt on positions scanned by spectrum was measured by a pH meter. The mathematical model between pH and Vis/NIR spectral measurements was established and developed based on partial least squares (PLS) by using Unscramble V9.2. Then 25 unknown samples from 5 different brands were predicted based on the mathematical model. The result shows that The correlation coefficient of pH based on PLS model is more than 0.890, and standard error of calibration (SEC) is 0.037, standard error of prediction (SEP) is 0.043. Through predicting the pH of 25 samples of yogurt from 5 different brands, the correlation coefficient between predictive value and measured value of those samples is more than 0918. The results show the good to excellent prediction performances. The Vis/NIR spectroscopy technique had a significant greater accuracy for determining the value of pH. It was concluded that the VisINIRS measurement technique can be used to measure pH of yogurt fast and accurately, and a new method for the measurement of pH of yogurt was established.

  13. [Validity and reliability of the screening questionnaire for geriatric depression used in the Mexican Health and Age Study].

    PubMed

    Aguilar-Navarro, Sara Gloria; Fuentes-Cantú, Alejandro; Avila-Funes, José Alberto; García-Mayo, Emilio José

    2007-01-01

    To assess the validity and reliability of a geriatric depression questionnaire used in the Mexican Health and Age Study (MHAS). The study was conducted at the Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán (INCMNSZ) clinic from May 2005 to March 2006. This depression screening nine-item questionnaire was validated using the Diagnostic and Statistical Manual of Mental Disorders (DSM-IV-TR) (fourth revised version) and Yesavage's 15-item Geriatric Depression Scale (GDS-15) criteria. The instrument belongs to the MHAS, a prospective panel study of health and aging in Mexico. A total of 199 subjects 65 years of age and older participated in the validation process (median age= 79.5 years). MHAS questionnaire result was significantly correlated to the clinical depression diagnosis (p<0.001) and to the GDS-15 score (p<0.001). Internal consistency was adequate (alpha coefficient: 0.74). The cutoff point > or = 5/9 points yielded an 80.7% and 68.7% sensitivity and specificity respectively. The fidelity for the test retest was excellent (intra-class correlation coefficient= 0.933). Finally, the Bland and Altman agreement points indicated a difference 0.22 percent points between test retest. The MHAS questionnaire is valid and trustworthy, and allows screening in the research field for the presence of depression in the elderly.

  14. Psychometric assessment of the Spiritual Climate Scale Arabic version for nurses in Saudi Arabia.

    PubMed

    Cruz, Jonas Preposi; Albaqawi, Hamdan Mohammad; Alharbi, Sami Melbes; Alicante, Jerico G; Vitorino, Luciano M; Abunab, Hamzeh Y

    2017-12-07

    To assess the psychometric properties of the Spiritual Climate Scale Arabic version for Saudi nurses. Evidence showed that a high level of spiritual climate in the workplace is associated with increased productivity and performance, enhanced emotional intelligence, organisational commitment and job satisfaction among nurses. A convenient sample of 165 Saudi nurses was surveyed in this descriptive, cross-sectional study. Cronbach's α and intraclass correlation coefficient of the 2 week test-retest scores were computed to establish reliability. Exploratory factor analysis was performed to support the validity of the Spiritual Climate Scale Arabic version. The Spiritual Climate Scale Arabic version manifested excellent content validity. Exploratory factor analysis supported a single factor with an explained variance of 73.2%. The Cronbach's α values of the scale ranged from .79 to .88, while the intraclass correlation coefficient value was .90. The perceived spiritual climate was associated with the respondents' hospital, gender, age and years of experience. Findings of this study support the sound psychometric properties of the Spiritual Climate Scale Arabic version. The Spiritual Climate Scale Arabic version can be used by nurse managers to assess the nurses' perception of the spiritual climate in any clinical area. This process can lead to spiritually centred interventions, thereby ensuring a clinical climate that accepts and respects different spiritual beliefs and practices. © 2017 John Wiley & Sons Ltd.

  15. A Monte Carlo risk assessment model for acrylamide formation in French fries.

    PubMed

    Cummins, Enda; Butler, Francis; Gormley, Ronan; Brunton, Nigel

    2009-10-01

    The objective of this study is to estimate the likely human exposure to the group 2a carcinogen, acrylamide, from French fries by Irish consumers by developing a quantitative risk assessment model using Monte Carlo simulation techniques. Various stages in the French-fry-making process were modeled from initial potato harvest, storage, and processing procedures. The model was developed in Microsoft Excel with the @Risk add-on package. The model was run for 10,000 iterations using Latin hypercube sampling. The simulated mean acrylamide level in French fries was calculated to be 317 microg/kg. It was found that females are exposed to smaller levels of acrylamide than males (mean exposure of 0.20 microg/kg bw/day and 0.27 microg/kg bw/day, respectively). Although the carcinogenic potency of acrylamide is not well known, the simulated probability of exceeding the average chronic human dietary intake of 1 microg/kg bw/day (as suggested by WHO) was 0.054 and 0.029 for males and females, respectively. A sensitivity analysis highlighted the importance of the selection of appropriate cultivars with known low reducing sugar levels for French fry production. Strict control of cooking conditions (correlation coefficient of 0.42 and 0.35 for frying time and temperature, respectively) and blanching procedures (correlation coefficient -0.25) were also found to be important in ensuring minimal acrylamide formation.

  16. Application of snapshot imaging spectrometer in environmental detection

    NASA Astrophysics Data System (ADS)

    Sun, Kai; Qin, Xiaolei; Zhang, Yu; Wang, Jinqiang

    2017-10-01

    This study aimed at the application of snapshot imaging spectrometer in environmental detection. The simulated sewage and dyeing wastewater were prepared and the optimal experimental conditions were determined. The white LED array was used as the detection light source and the image of the sample was collected by the imaging spectrometer developed in the laboratory to obtain the spectral information of the sample in the range of 400-800 nm. The standard curve between the absorbance and the concentration of the samples was established. The linear range of a single component of Rhoda mine B was 1-50 mg/L, the linear correlation coefficient was more than 0.99, the recovery was 93%-113% and the relative standard deviations (RSD) was 7.5%. The linear range of chemical oxygen demand (COD) standard solution was 50-900mg/L, the linear correlation coefficient was 0.981, the recovery was 91% -106% and the relative standard deviation (RSD) was 6.7%. The rapid, accurate and precise method for detecting dyes showed an excellent promise for on-site and emergency detection in environment. At the request of the proceedings editor, an updated version of this article was published on 17 October 2017. The original version of this article was replaced due to an accidental inversion of Figure 2 and Figure 3. The Figures have been corrected in the updated and republished version.

  17. Electrochemical Determination of Metronidazole in Tablet Samples Using Carbon Paste Electrode

    PubMed Central

    Nikodimos, Yosef

    2016-01-01

    Cyclic voltammetric investigation of metronidazole at carbon paste electrode revealed an irreversible reduction peak centered at about −0.4 V. Observed peak potential shift with pH in the range 2.0 to 8.5 indicated the involvement of protons during the reduction of metronidazole, whereas the peak potential shift with scan rate in the range 10–250 mV/s confirmed the irreversibility of the reduction reaction. A better correlation coefficient for the dependence of peak current on the scan rate than on the square root of scan rate indicated an adsorption controlled kinetics. Under the optimized method and solution parameters, an excellent linearity between the reductive peak current and the concentration of metronidazole was observed in the concentration range 1.0 × 10−6 to 5.0 × 10−4 M with a correlation coefficient, method detection limit (based on s = 3σ), and limit of quantification of 0.999, 2.97 × 10−7 M and 9.91 × 10−7 M, respectively. Good recovery results for spiked metronidazole in tablet samples and selective determination of metronidazole in tablet formulations in the presence of selected potential interferents such as rabeprazole, omeprazole, and tinidazole confirmed the potential applicability of the developed method for the determination of metronidazole in real samples like pharmaceutical tablets. PMID:27119041

  18. ppcor: An R Package for a Fast Calculation to Semi-partial Correlation Coefficients.

    PubMed

    Kim, Seongho

    2015-11-01

    Lack of a general matrix formula hampers implementation of the semi-partial correlation, also known as part correlation, to the higher-order coefficient. This is because the higher-order semi-partial correlation calculation using a recursive formula requires an enormous number of recursive calculations to obtain the correlation coefficients. To resolve this difficulty, we derive a general matrix formula of the semi-partial correlation for fast computation. The semi-partial correlations are then implemented on an R package ppcor along with the partial correlation. Owing to the general matrix formulas, users can readily calculate the coefficients of both partial and semi-partial correlations without computational burden. The package ppcor further provides users with the level of the statistical significance with its test statistic.

  19. Evaluation of two portable meters for determination of blood triglyceride concentration in dogs.

    PubMed

    Kluger, Elissa K; Dhand, Navneet K; Malik, Richard; Ilkin, William J; Snow, David H; Govendir, Merran

    2010-02-01

    To evaluate agreement between 2 portable triglyceride meters and a veterinary laboratory for measurement of blood triglyceride concentrations in dogs and evaluate effects of Hct and blood volume analyzed. 97 blood samples collected from 60 dogs. Triglyceride concentrations were measured in blood by use of 2 meters and compared with serum triglyceride concentrations determined by a veterinary laboratory. Within- and between-day precision, accuracy, and effects of blood volume and Hct were analyzed. Accuracy of both meters varied with triglyceride concentration, although both accurately delineated dogs with triglyceride concentrations < 180 mg/dL versus > or = 180 mg/dL. One meter had results with excellent overall correlation with results of the standard laboratory method, with a concordance correlation coefficient of 0.94 and mean difference of 20.3 mg/dL. The other meter had a good overall concordance correlation coefficient of 0.86 with a higher absolute mean difference of -27.7 mg/dL. Results were only affected by blood volume; triglyceride concentrations determined via both meters were significantly lower when 7 microL of EDTA-anticoagulated blood was used, compared with larger volumes. 1 meter had greater accuracy in the range of 140 to 400 mg/dL and was therefore well suited to detect hypertriglyceridemia. The other meter was accurate with triglyceride values < 140 mg/dL and yielded results similar to those of the veterinary laboratory in the range of 140 to 400 mg/dL, therefore being suitable for determination of triglyceride concentrations in nonfed dogs and dogs with mildly high concentrations.

  20. Psychometric Properties of the Persian Translation of the Sexual Quality of Life–Male Questionnaire

    PubMed Central

    Maasoumi, Raziyeh; Mokarami, Hamidreza; Nazifi, Morteza; Stallones, Lorann; Taban, Abrahim; Yazdani Aval, Mohsen; Samimi, Kazem

    2016-01-01

    Sexual dysfunction has been demonstrated to be related to a poor quality of life. These dysfunctions are especially prevalent among men. This cross-sectional study aimed to investigate the psychometric properties of the Persian translation of the Sexual Quality of Life–Male (SQOL-M), translated and adapted to measure sexual quality of life among Iranian men. Forward–backward procedures were applied in translating the original SQOL-M into Persian, and then the psychometric properties of the Persian translation of the SQOL-M were studied. A total of 181 participants (23-60 years old) were included in the study. Validity was assessed by construct validity using confirmatory factor analysis, convergent validity, and content validity. The international index of erectile function (IIEF) and the work ability index were used to study the convergent validity. Reliability was evaluated through internal consistency and test–retest reliability analyses. The results from confirmatory factor analysis confirmed a one-factor solution for the Persian version of the SQOL-M. Content validity of the translated measure was endorsed by 10 specialists. Pearson correlations indicated that work ability index score, dimensions of the IIEF, and the IIEF total score were positively correlated with the Persian version of the SQOL-M (p < .001). Reliability evaluation indicated a high internal consistency and test–retest reliability. The Cronbach’s alpha coefficient and intraclass correlation coefficients were .96 and .95, respectively. Results indicated that the Persian version of the SQOL-M has good to excellent psychometric properties and can be used to assess the sexual quality of life among Iranian men. PMID:26856758

  1. Psychometric Properties of the Persian Translation of the Sexual Quality of Life-Male Questionnaire.

    PubMed

    Maasoumi, Raziyeh; Mokarami, Hamidreza; Nazifi, Morteza; Stallones, Lorann; Taban, Abrahim; Yazdani Aval, Mohsen; Samimi, Kazem

    2017-05-01

    Sexual dysfunction has been demonstrated to be related to a poor quality of life. These dysfunctions are especially prevalent among men. This cross-sectional study aimed to investigate the psychometric properties of the Persian translation of the Sexual Quality of Life-Male (SQOL-M), translated and adapted to measure sexual quality of life among Iranian men. Forward-backward procedures were applied in translating the original SQOL-M into Persian, and then the psychometric properties of the Persian translation of the SQOL-M were studied. A total of 181 participants (23-60 years old) were included in the study. Validity was assessed by construct validity using confirmatory factor analysis, convergent validity, and content validity. The international index of erectile function (IIEF) and the work ability index were used to study the convergent validity. Reliability was evaluated through internal consistency and test-retest reliability analyses. The results from confirmatory factor analysis confirmed a one-factor solution for the Persian version of the SQOL-M. Content validity of the translated measure was endorsed by 10 specialists. Pearson correlations indicated that work ability index score, dimensions of the IIEF, and the IIEF total score were positively correlated with the Persian version of the SQOL-M ( p < .001). Reliability evaluation indicated a high internal consistency and test-retest reliability. The Cronbach's alpha coefficient and intraclass correlation coefficients were .96 and .95, respectively. Results indicated that the Persian version of the SQOL-M has good to excellent psychometric properties and can be used to assess the sexual quality of life among Iranian men.

  2. Psychometric properties of the Albanian version of the Orofacial Esthetic Scale: OES-ALB.

    PubMed

    Bimbashi, Venera; Čelebić, Asja; Staka, Gloria; Hoxha, Flurije; Peršić, Sanja; Petričević, Nikola

    2015-08-26

    The aim was to adapt the Orofacial Esthetic Scale (OES) and to test psychometric properties of the Albanian language version in the cultural environment of the Republic of Kosovo. The OES questionnaire was translated from the original English version according to the accepted techniques. The reliability (internal consistency), and validity (construct, convergent and discriminative) were tested in 169 subjects, test-retest in 61 dental students (DS), and responsiveness in 51 prosthodontic patients with treatment needs (PPTN). The corrected item correlation coefficients of OES-ALB ranged from 0.686 to 0.909. The inter-item correlation coefficient ranged between 0.572 and 0.919. The Cronbach's alpha was 0.961 and IIC 0.758. Test- retest was confirmed by good ICCs and by no significant differences of the OES scores through the period of 14 days without any orofacial changes (p > 0.05). Construct validity was proved by the presence of one-factor composition that assumed 79.079% of the variance. Convergent validity showed significant correlation between one general question about satisfaction with orofacial esthetics and the OES summary score, as well as between the sum of the 3 OHIP-ALB49 questions related to orofacial aesthetics and the OES summary score. Discriminative validity was confirmed with statistically significant differences between DS, prosthodontic patients without treatment need and PPTN (p < 0.01). Responsiveness was confirmed by a significant increase of OES scores after PPTN patients received new fixed partial or removable dentures (P < 0.001). The results proved excellent psychometric properties of the OES-ALB questionnaire in the Republic of Kosovo.

  3. Fetal frontomaxillary facial angle between 11 and 13 + 6 weeks of gestation in a Brazilian population: influence of different races.

    PubMed

    Panigassi, Ana Paula Nascimento; Araujo Júnior, Edward; Nardozza, Luciano Marcondes Machado; Moron, Antonio Fernandes; Pares, David Baptista da Silva

    2013-07-01

    To evaluate the influence of different races over the measurement of the frontomaxillary facial angle between 11 and 13 + 6 weeks of pregnancy in a Brazilian population. A cross-sectional study was conducted with 332 healthy pregnant women, with a crown-rump length (CRL) between 47 and 84 mm. Such measurements were taken abdominally, using the mid-sagittal plane, and the angle was measured by tracing a line over the palate and a line from the anterosuperior maxillary angle all the way to the external part of the forehead. As for the reference intervals, a simple linear regression between the frontomaxillary facial angle and the CRL was used, as well as Pearson's correlation coefficient (r). To evaluate the difference between races, a variance analysis was used (ANOVA). To calculate reproducibility, the intraclass correlation coefficient (ICC) was used. The means for the fetal frontomaxillary facial angle in white, black and mixed races were 81.8 ± 6.6; 82.2 ± 6.1 and 81.4 ± 6.2 mm, respectively. There was no statistical difference between races (p = 0.713). A decreasing correlation between the frontomaxillary facial angle and the CRL was observed for the black (r = -0.450) and mixed (r = -0.212) races. Excellent intraobserver reproducibility was observed, as well as a satisfactory interobserver reproducibility, with ICC of 0.858 and 0.605, respectively. There were no significative statistical differences in the measurement of the fetal frontomaxillary facial angle between 11 and 13 + 6 weeks of pregnancy in the different races in a Brazilian population.

  4. Reliability and validity of the Iranian version of the Pediatric Quality of Life Inventory™ 4.0 Generic Core Scales in adolescents.

    PubMed

    Amiri, Parisa; M Ardekani, Emad; Jalali-Farahani, Sara; Hosseinpanah, Farhad; Varni, James W; Ghofranipour, Fazlollah; Montazeri, Ali; Azizi, Fereidoun

    2010-12-01

    The objective of this study was to investigate the reliability and validity of the Iranian version of the Pediatric Quality of Life Inventory™ 4.0 (PedsQL™ 4.0) Generic Core Scales in adolescents After linguistic validation, the Iranian version of the PedsQL™ 4.0 was completed by 848 healthy and 26 chronically ill adolescents aged 13-18 years and their parents. The internal consistency as measured by Cronbach's alpha coefficients exceeded the minimum reliability standard of .70. No floor effects were observed. Ceiling effects detected ranged from 1.5% for adolescent self-report total scale score to 42.2% for self-report social functioning. All monotrait-multimethod correlations were higher than multitrait-multimethod correlations. The intraclass correlation coefficients (ICC) between adolescent self-report and parent proxy-report showed good to excellent agreement. Exploratory factor analysis supported mainly comparable results with the original US English dialect version. The results of the confirmatory factor analysis for 5-factor models for both self-report and proxy-report indicated acceptable fit for the proposed models. Regarding gender and health status, as hypothesized from previous studies, girls reported lower health-related quality of life than boys on the total score, physical and emotional functioning, and healthy adolescents reported significantly higher health-related quality of life than those with chronic illnesses. The findings support the initial reliability and validity of the Iranian version of the PedsQL™ 4.0 as a generic instrument to measure HRQOL of adolescents in Iran.

  5. Pain assessment in elderly with dementia: Brazilian validation of the PACSLAC scale

    PubMed Central

    Thé, Karol Bezerra; Gazoni, Fernanda Martins; Cherpak, Guilherme Liausu; Lorenzet, Isabel Clasen; dos Santos, Luciana Alves; Nardes, Edlene Maria; dos Santos, Fânia Cristina

    2016-01-01

    ABSTRACT Objective To validate the Pain Assessment Checklist for Seniors with Limited Ability to Communicate – Portuguese in demented elderly and to analyze its measurement properties. Methods We evaluated 50 elderly with dementia, residing in a nursing home and with limited communication ability, when exposed to potentially painful situations. The tool was applied at two different moments. First, two interviewers applied it simultaneously, and the intensity of pain was asked based on the caregiver’s opinion. After 14 days, with no analgesic intervention, one of the interviewers applied it again. Results The sample comprised more females, aged over 80 years, with dementia due to Alzheimer, presenting musculoskeletal pain of moderate to severe intensity. The psychometric properties of the tool demonstrated appropriate internal consistency (Cronbach’s alpha coefficient of 0.827). The scale had excellent reproducibility, according to the intraclass correlation coefficient, and the tool has been duly validated. Conclusion The Pain Assessment Checklist for Seniors with Limited Ability to Communicate – Portuguese had adequate measuring properties for use with elderly presenting limited communication. PMID:27462888

  6. Development of a modified instrument to measure anticipatory grieving in Jordanian parents of children diagnosed with cancer: the Marwit and Meuser Caregiver Inventory Childhood Cancer.

    PubMed

    Al-Gamal, Ekhlas; Long, Tony; Livesley, Joan

    2009-01-01

    The purpose of this article is to report on the development and field testing for validity and reliability of a modified version of the Marwit and Meuser Caregiver Inventory (MM-CGI) for the assessment of anticipatory grief among Jordanian parents of children with cancer (the MM-CGI Childhood Cancer). In 2006, a 50-item MM-CGI Childhood Cancer was administered to 140 Jordanian parents living with a child with cancer. The Cronbach alpha coefficient for the total instrument was .95, and Cronbach alpha coefficients for each of the 3 subscales was .91 for personal sacrifice burden, .90 for heartfelt sadness and longing, and .86 for worry and felt isolation. The construct validity of this instrument was supported by demonstrating a significant and positive correlation with the Anticipatory Grief Scale. The MM-CGI Childhood Cancer demonstrated strong convergent validity and excellent internal consistency reliability. However, further testing with a larger sample to facilitate factor analysis is needed to complete the validation process.

  7. Evaluating Human Sensory Perceptions and the Compartment Bag Test Assays as Proxies for the Presence and Concentration of Escherichia coli in Drinking Water in Western Kenya.

    PubMed

    Brooks, Yolanda M; Collins, Shalean M; Mbullo, Patrick; Boateng, Godfred O; Young, Sera L; Richardson, Ruth E

    2017-10-01

    We compared the concentrations of Escherichia coli quantified with Colilert ™ and the compartment bag test (CBT) in the source water and household stored drinking water (SDW) of 35 households in western Kenya. We also investigated the associations of the perceptions of organoleptic properties and overall quality with ≥ 1 MPN/100 mL E. coli in SDW. Participants who rated the taste or smell of their SDW "< 5" on a 1 = "poor" to 5 = "excellent" Likert scale were 8.71 or 7.04 times more likely, respectively, to have ≥ 1 MPN/100 mL E. coli . Organoleptic properties are innate, albeit imperfect, indicators of fecal pollution in water. Within their shared quantification range, concentrations of E. coli enumerated with Colilert and CBT were similar and had a significant correlation coefficient, 0.896 (95% confidence interval = 0.691-1.101). The methods had moderate agreement within the World Health Organization's health risk levels (Cohen's Kappa coefficient = 0.640). In low-resource settings, CBT provides comparable assessments of E. coli concentrations to Colilert.

  8. Dynamic Measurement of Tumor Vascular Permeability and Perfusion using a Hybrid System for Simultaneous Magnetic Resonance and Fluorescence Imaging.

    PubMed

    Ren, Wuwei; Elmer, Andreas; Buehlmann, David; Augath, Mark-Aurel; Vats, Divya; Ripoll, Jorge; Rudin, Markus

    2016-04-01

    Assessing tumor vascular features including permeability and perfusion is essential for diagnostic and therapeutic purposes. The aim of this study was to compare fluorescence and magnetic resonance imaging (MRI)-based vascular readouts in subcutaneously implanted tumors in mice by simultaneous dynamic measurement of tracer uptake using a hybrid fluorescence molecular tomography (FMT)/MRI system. Vascular permeability was measured using a mixture of extravascular imaging agents, GdDOTA and the dye Cy5.5, and perfusion using a mixture of intravascular agents, Endorem and a fluorescent probe (Angiosense). Dynamic fluorescence reflectance imaging (dFRI) was integrated into the hybrid system for high temporal resolution. Excellent correspondence between uptake curves of Cy5.5/GdDOTA and Endorem/Angiosense has been found with correlation coefficients R > 0.98. The two modalities revealed good agreement regarding permeability coefficients and centers-of-gravity of the imaging agent distribution. The FMT/dFRI protocol presented is able to accurately map physiological processes and poses an attractive alternative to MRI for characterizing tumor neoangiogenesis.

  9. Impact of anisotropy on the structure and dynamics of ionic liquids: A computational study of 1-butyl-3-methyl-imidazolium trifluoroacetate

    NASA Astrophysics Data System (ADS)

    Schröder, C.; Rudas, T.; Neumayr, G.; Gansterer, W.; Steinhauser, O.

    2007-07-01

    The complex ionic network of 1-butyl-3-methyl-imidazolium trifluoroacetate was simulated by means of the molecular dynamics methods over a time period of 100ns. The influence of the anisotropy of the shape and charge distribution of both the cations and the anions on the local (molecular) and global (collective) structure and dynamics is analyzed. The distance-dependent g coefficients of the orientational probability function g(r,Ω) were found to be an excellent way to interpret local structure. Thereby, the combination and interrelation of individual g coefficients elucidate the mutual orientation. Dynamics at the molecular level is characterized by the time correlation function of the center-of-mass corrected molecular dipole moment μcm. Upon uniting the set of molecular dipoles to a single collective rotational dipole moment, MD, dynamics on a global level is studied. Decomposing into subsets of cations and anions respective self terms as well as the prominent cross term can be extracted. This decomposition also enables a detailed peak assignment in dielectric spectra.

  10. Impact of anisotropy on the structure and dynamics of ionic liquids: a computational study of 1-butyl-3-methyl-imidazolium trifluoroacetate.

    PubMed

    Schröder, C; Rudas, T; Neumayr, G; Gansterer, W; Steinhauser, O

    2007-07-28

    The complex ionic network of 1-butyl-3-methyl-imidazolium trifluoroacetate was simulated by means of the molecular dynamics methods over a time period of 100 ns. The influence of the anisotropy of the shape and charge distribution of both the cations and the anions on the local (molecular) and global (collective) structure and dynamics is analyzed. The distance-dependent g coefficients of the orientational probability function g(r,Omega) were found to be an excellent way to interpret local structure. Thereby, the combination and interrelation of individual g coefficients elucidate the mutual orientation. Dynamics at the molecular level is characterized by the time correlation function of the center-of-mass corrected molecular dipole moment mucm. Upon uniting the set of molecular dipoles to a single collective rotational dipole moment, MD, dynamics on a global level is studied. Decomposing into subsets of cations and anions respective self terms as well as the prominent cross term can be extracted. This decomposition also enables a detailed peak assignment in dielectric spectra.

  11. Reliable and fast volumetry of the lumbar spinal cord using cord image analyser (Cordial).

    PubMed

    Tsagkas, Charidimos; Altermatt, Anna; Bonati, Ulrike; Pezold, Simon; Reinhard, Julia; Amann, Michael; Cattin, Philippe; Wuerfel, Jens; Fischer, Dirk; Parmar, Katrin; Fischmann, Arne

    2018-04-30

    To validate the precision and accuracy of the semi-automated cord image analyser (Cordial) for lumbar spinal cord (SC) volumetry in 3D T1w MRI data of healthy controls (HC). 40 3D T1w images of 10 HC (w/m: 6/4; age range: 18-41 years) were acquired at one 3T-scanner in two MRI sessions (time interval 14.9±6.1 days). Each subject was scanned twice per session, allowing determination of test-retest reliability both in back-to-back (intra-session) and scan-rescan images (inter-session). Cordial was applied for lumbar cord segmentation twice per image by two raters, allowing for assessment of intra- and inter-rater reliability, and compared to a manual gold standard. While manually segmented volumes were larger (mean: 2028±245 mm 3 vs. Cordial: 1636±300 mm 3 , p<0.001), accuracy assessments between manually and semi-automatically segmented images showed a mean Dice-coefficient of 0.88±0.05. Calculation of within-subject coefficients of variation (COV) demonstrated high intra-session (1.22-1.86%), inter-session (1.26-1.84%), as well as intra-rater (1.73-1.83%) reproducibility. No significant difference was shown between intra- and inter-session reproducibility or between intra-rater reliabilities. Although inter-rater reproducibility (COV: 2.87%) was slightly lower compared to all other reproducibility measures, between rater consistency was very strong (intraclass correlation coefficient: 0.974). While under-estimating the lumbar SCV, Cordial still provides excellent inter- and intra-session reproducibility showing high potential for application in longitudinal trials. • Lumbar spinal cord segmentation using the semi-automated cord image analyser (Cordial) is feasible. • Lumbar spinal cord is 40-mm cord segment 60 mm above conus medullaris. • Cordial provides excellent inter- and intra-session reproducibility in lumbar spinal cord region. • Cordial shows high potential for application in longitudinal trials.

  12. Optimal portfolio strategy with cross-correlation matrix composed by DCCA coefficients: Evidence from the Chinese stock market

    NASA Astrophysics Data System (ADS)

    Sun, Xuelian; Liu, Zixian

    2016-02-01

    In this paper, a new estimator of correlation matrix is proposed, which is composed of the detrended cross-correlation coefficients (DCCA coefficients), to improve portfolio optimization. In contrast to Pearson's correlation coefficients (PCC), DCCA coefficients acquired by the detrended cross-correlation analysis (DCCA) method can describe the nonlinear correlation between assets, and can be decomposed in different time scales. These properties of DCCA make it possible to improve the investment effect and more valuable to investigate the scale behaviors of portfolios. The minimum variance portfolio (MVP) model and the Mean-Variance (MV) model are used to evaluate the effectiveness of this improvement. Stability analysis shows the effect of two kinds of correlation matrices on the estimation error of portfolio weights. The observed scale behaviors are significant to risk management and could be used to optimize the portfolio selection.

  13. Relationships among the slopes of lines derived from various data analysis techniques and the associated correlation coefficient

    NASA Technical Reports Server (NTRS)

    Cohen, S. C.

    1980-01-01

    A technique for fitting a straight line to a collection of data points is given. The relationships between the slopes and correlation coefficients, and between the corresponding standard deviations and correlation coefficient are given.

  14. Correlation Between Minimum Apparent Diffusion Coefficient (ADCmin) and Tumor Cellularity: A Meta-analysis.

    PubMed

    Surov, Alexey; Meyer, Hans Jonas; Wienke, Andreas

    2017-07-01

    Diffusion-weighted imaging (DWI) is a magnetic resonance imaging (MRI) technique based on measure of water diffusion that can provide information about tissue microstructure, especially about cell count. Increase of cell density induces restriction of water diffusion and decreases apparent diffusion coefficient (ADC). ADC can be divided into three sub-parameters: ADC minimum or ADC min , mean ADC or ADC mean and ADC maximum or ADC max Some studies have suggested that ADC min shows stronger correlations with cell count in comparison to other ADC fractions and may be used as a parameter for estimation of tumor cellularity. The aim of the present meta-analysis was to summarize correlation coefficients between ADC min and cellularity in different tumors based on large patient data. For this analysis, MEDLINE database was screened for associations between ADC and cell count in different tumors up to September 2016. For this work, only data regarding ADC min were included. Overall, 12 publications with 317 patients were identified. Spearman's correlation coefficient was used to analyze associations between ADC min and cellularity. The reported Pearson correlation coefficients in some publications were converted into Spearman correlation coefficients. The pooled correlation coefficient for all included studies was ρ=-0.59 (95% confidence interval (CI)=-0.72 to -0.45), heterogeneity Tau 2 =0.04 (p<0.0001), I 2 =73%, test for overall effect Z=8.67 (p<0.00001). ADC min correlated moderately with tumor cellularity. The calculated correlation coefficient is not stronger in comparison to the reported coefficient for ADC mean and, therefore, ADC min does not represent a better means to reflect cellularity. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  15. Excellent vacuum tribological properties of Pb/PbS film deposited by RF magnetron sputtering and ion sulfurizing.

    PubMed

    Guozheng, Ma; Binshi, Xu; Haidou, Wang; Shuying, Chen; Zhiguo, Xing

    2014-01-08

    Soft metal Pb film of 3 μm in thickness was deposited on AISI 440C steel by RF magnetron sputtering, and then some of the Pb film samples were treated by low-temperature ion sulfurizing (LTIS) and formed Pb/PbS composite film. Tribological properties of the Pb and Pb/PbS films were tested contrastively in vacuum and air condition using a self-developed tribometer (model of MSTS-1). Scanning electron microscopy (SEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) were adopted to analyze the microstructure and chemical construction of the films and their worn surfaces. The results show that a mass of Pb was changed to PbS during the process of LTIS. In air condition, owing to the severe oxidation effect, pure Pb film showed relatively high friction coefficients (0.6), and Pb/PbS composite film also lost its friction-reduction property after sliding for a short time. In a vacuum, the average friction coefficients of Pb film were about 0.1, but the friction coefficient curve fluctuated obviously. And the Pb/PbS composite film exhibited excellent tribological properties in vacuum condition. Its friction coefficients keep stable at a low value of about 0.07 for a long time. If takes the value of friction coefficients exceeding 0.2 continuously as a criterion of lubrication failure, the sliding friction life of Pb/PbS film was as long as 3.2 × 10(5) r, which is 8 times of that of the Pb film. It can be concluded that the Pb/PbS film has excellent vacuum tribological properties and important foreground for applying in space solid lubrication related fields.

  16. Measuring the food and built environments in urban centres: reliability and validity of the EURO-PREVOB Community Questionnaire.

    PubMed

    Pomerleau, J; Knai, C; Foster, C; Rutter, H; Darmon, N; Derflerova Brazdova, Z; Hadziomeragic, A F; Pekcan, G; Pudule, I; Robertson, A; Brunner, E; Suhrcke, M; Gabrijelcic Blenkus, M; Lhotska, L; Maiani, G; Mistura, L; Lobstein, T; Martin, B W; Elinder, L S; Logstrup, S; Racioppi, F; McKee, M

    2013-03-01

    The authors designed an instrument to measure objectively aspects of the built and food environments in urban areas, the EURO-PREVOB Community Questionnaire, within the EU-funded project 'Tackling the social and economic determinants of nutrition and physical activity for the prevention of obesity across Europe' (EURO-PREVOB). This paper describes its development, reliability, validity, feasibility and relevance to public health and obesity research. The Community Questionnaire is designed to measure key aspects of the food and built environments in urban areas of varying levels of affluence or deprivation, within different countries. The questionnaire assesses (1) the food environment and (2) the built environment. Pilot tests of the EURO-PREVOB Community Questionnaire were conducted in five to 10 purposively sampled urban areas of different socio-economic status in each of Ankara, Brno, Marseille, Riga, and Sarajevo. Inter-rater reliability was compared between two pairs of fieldworkers in each city centre using three methods: inter-observer agreement (IOA), kappa statistics, and intraclass correlation coefficients (ICCs). Data were collected successfully in all five cities. Overall reliability of the EURO-PREVOB Community Questionnaire was excellent (inter-observer agreement (IOA) > 0.87; intraclass correlation coefficients (ICC)s > 0.91 and kappa statistics > 0.7. However, assessment of certain aspects of the quality of the built environment yielded slightly lower IOA coefficients than the quantitative aspects. The EURO-PREVOB Community Questionnaire was found to be a reliable and practical observational tool for measuring differences in community-level data on environmental factors that can impact on dietary intake and physical activity. The next step is to evaluate its predictive power by collecting behavioural and anthropometric data relevant to obesity and its determinants. Copyright © 2013 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  17. Correlation of human papillomavirus status with apparent diffusion coefficient of diffusion-weighted MRI in head and neck squamous cell carcinomas.

    PubMed

    Driessen, Juliette P; van Bemmel, Alexander J M; van Kempen, Pauline M W; Janssen, Luuk M; Terhaard, Chris H J; Pameijer, Frank A; Willems, Stefan M; Stegeman, Inge; Grolman, Wilko; Philippens, Marielle E P

    2016-04-01

    Identification of prognostic patient characteristics in head and neck squamous cell carcinoma (HNSCC) is of great importance. Human papillomavirus (HPV)-positive HNSCCs have favorable response to (chemo)radiotherapy. Apparent diffusion coefficient, derived from diffusion-weighted MRI, has also shown to predict treatment response. The purpose of this study was to evaluate the correlation between HPV status and apparent diffusion coefficient. Seventy-three patients with histologically proven HNSCC were retrospectively analyzed. Mean pretreatment apparent diffusion coefficient was calculated by delineation of total tumor volume on diffusion-weighted MRI. HPV status was analyzed and correlated to apparent diffusion coefficient. Six HNSCCs were HPV-positive. HPV-positive HNSCC showed significantly lower apparent diffusion coefficient compared to HPV-negative. This correlation was independent of other patient characteristics. In HNSCC, positive HPV status correlates with low mean apparent diffusion coefficient. The favorable prognostic value of low pretreatment apparent diffusion coefficient might be partially attributed to patients with a positive HPV status. © 2015 Wiley Periodicals, Inc. Head Neck 38: E613-E618, 2016. © 2015 Wiley Periodicals, Inc.

  18. Similarity analysis between chromosomes of Homo sapiens and monkeys with correlation coefficient, rank correlation coefficient and cosine similarity measures

    PubMed Central

    Someswara Rao, Chinta; Viswanadha Raju, S.

    2016-01-01

    In this paper, we consider correlation coefficient, rank correlation coefficient and cosine similarity measures for evaluating similarity between Homo sapiens and monkeys. We used DNA chromosomes of genome wide genes to determine the correlation between the chromosomal content and evolutionary relationship. The similarity among the H. sapiens and monkeys is measured for a total of 210 chromosomes related to 10 species. The similarity measures of these different species show the relationship between the H. sapiens and monkey. This similarity will be helpful at theft identification, maternity identification, disease identification, etc. PMID:26981409

  19. Similarity analysis between chromosomes of Homo sapiens and monkeys with correlation coefficient, rank correlation coefficient and cosine similarity measures.

    PubMed

    Someswara Rao, Chinta; Viswanadha Raju, S

    2016-03-01

    In this paper, we consider correlation coefficient, rank correlation coefficient and cosine similarity measures for evaluating similarity between Homo sapiens and monkeys. We used DNA chromosomes of genome wide genes to determine the correlation between the chromosomal content and evolutionary relationship. The similarity among the H. sapiens and monkeys is measured for a total of 210 chromosomes related to 10 species. The similarity measures of these different species show the relationship between the H. sapiens and monkey. This similarity will be helpful at theft identification, maternity identification, disease identification, etc.

  20. [Evaluation on the validity and reliability of the Diabetes Self-management Knowledge, Attitude, and Behavior Assessment Scale (DSKAB)].

    PubMed

    Liu, Xiaoli; Dai, Long; Chen, Bo; Feng, Nongping; Wu, Qianhui; Lin, Yonghai; Zhang, Lan; Tan, Dong; Zhang, Jinhua; Tu, Huijuan; Li, Changfeng; Wang, Wenjuan

    2016-01-01

    To evaluate the validity and reliability of Diabetes Self-management Knowledge, Attitude, and Behavior Assessment Scale (DSKAB). We selected 460 patients with diabetes in the community, used the scale which was after two rounds of the Delphi method and pilot study. Investigators surveyed the patients by the way of face to face. by draw lots, we selected 25 community diabetes randomly for repeating investigations after one week. The validity analyses included face validity, content validity, construct validity and discriminant validity. The reliability analyses included Cronbach's α coefficient, θ coefficient, Ω coefficient, split-half reliability and test-retest reliability. This study distributed a total of 460 questionnaires, reclaimed 442, qualified 432. The score of the scale was 254.59 ± 28.90, the scores of the knowledge, attitude, behavior sub-scales were 82.44 ± 11.24, 63.53 ± 5.77 and 108.61 ± 17.55, respectively. It had excellent face validity and content validity. The correlation coefficient was from 0.71 to 0.91 among three sub-scales and the scale, P<0.001. The common factor cumulative variance contribution rate of the scale and three sub-scales was from 57.28% to 67.19%, which achieved more than 50% of the approved standard, there was 25 common factors, 91 items of the total 98 items held factor loading ≥0.40 in its relevant common factor, it had good construct validity. The scores of high group and low group in three sub-scales were: knowledge (91.12 ± 3.62) and (69.96 ± 11.20), attitude (68.75 ± 4.51) and (58.79 ± 4.87), behavior (129.38 ± 8.53) and (89.65 ± 11.34),mean scores of three sub-scales were apparently different, which compared between high score group and low score group, the t value were - 19.45, -16.24 and -30.29, respectively, P<0.001, and it had good discriminant validity. The Cronbach's α coefficient of the scale and three sub-scales was from 0.79 to 0.93, the θ coefficient was from 0.86 to 0.95, the Ω coefficient was from 0.90 to 0.98, split-half reliability was from 0.89 to 0.95.Test-retest reliability of the scale was 0.51;the three sub-scales was from 0.46 to 0.52, P<0.05. The validity and reliability of the Diabetes Self-management Knowledge, Attitude, and Behavior Assessment Scale are excellent, which is a suitable instrument to evaluate the self-management for patients with diabetes.

  1. Effects of Sample Handling and Analytical Procedures on Thyroid Hormone Concentrations in Pregnant Women's Plasma.

    PubMed

    Villanger, Gro Dehli; Learner, Emily; Longnecker, Matthew P; Ask, Helga; Aase, Heidi; Zoeller, R Thomas; Knudsen, Gun P; Reichborn-Kjennerud, Ted; Zeiner, Pål; Engel, Stephanie M

    2017-05-01

    Maternal thyroid function is a critical mediator of fetal brain development. Pregnancy-related physiologic changes and handling conditions of blood samples may influence thyroid hormone biomarkers. We investigated the reliability of thyroid hormone biomarkers in plasma of pregnant women under various handling conditions. We enrolled 17 pregnant women; collected serum and plasma were immediately frozen. Additional plasma aliquots were subjected to different handling conditions before the analysis of thyroid biomarkers: storage at room temperature for 24 or 48 hours before freezing and an extra freeze-thaw cycle. We estimated free thyroid hormone indices in plasma based on T3 uptake. High correlations between plasma and serum (>0.94) and intraclass correlation coefficients for plasma handling conditions (0.96 to 1.00) indicated excellent reliability for all thyroid hormone biomarkers. Delayed freezing and freeze-thaw cycles did not affect reliability of biomarkers of thyroid function in plasma during pregnancy. See video abstract at, http://links.lww.com/EDE/B180.

  2. Reliability of the detailed assessment of speed of handwriting on Flemish children.

    PubMed

    Simons, Johan; Probst, Michel

    2014-01-01

    This study evaluates the reliability of the Detailed Assessment of Speed of Handwriting (DASH) in a Dutch-speaking sample of children. The sample included 650 boys and 513 girls (age range = 9-16 years). Handwriting speed measurements were obtained using the DASH. Interrater agreement, test-retest reliability, and internal consistency were calculated; gender and age effects were analyzed. Interrater agreement shows excellent reliability with intraclass correlation coefficients of at least 0.94. Test-retest correlations ranged from r = 0.65 to r = 0.81. The internal consistency measures, calculated with Cronbach's alpha, were between 0.88 and 0.94. Both gender and age have a significant effect on handwriting speed, with F (7.1144) = 17.43 (P < .001) for gender and F (7.1144) = 21.8 (P < .001) for age. The DASH is a reliable assessment tool to evaluate handwriting speed of Dutch-speaking children. There is a tendency of girls to write faster than boys.

  3. Validation of mid-infrared spectroscopy for macronutrient analysis of human milk.

    PubMed

    Parat, S; Groh-Wargo, S; Merlino, S; Wijers, C; Super, D M

    2017-07-01

    Human milk has considerable variation in its composition. Hence, the nutrient profile is only an estimate and can result in under- or over-estimation of the intake of preterm infants. Mid-infrared (MIR) spectroscopy is an evolving technique for analyzing human milk but needs validation before use in clinical practice. Human milk samples from 35 mothers delivering at 35 weeks to term gestation were analyzed for macronutrients by MIR spectroscopy and by standard laboratory methods using Kjeldahl assay for protein, Mojonnier assay for fat and high-pressure liquid chromatography assay for lactose. MIR analysis of the macronutrients in human milk correlated well with standard laboratory tests with intraclass correlation coefficients of 0.997 for fat, 0.839 for protein and 0.776 for lactose. Agreement between the two methods was excellent for fat, and moderate for protein and lactose (P<0.001). This methodological paper provides evidence that MIR spectroscopy can be used to analyze macronutrient composition of human milk. Agreement between the methodologies varies by macronutrient.

  4. A Validation Study of the Japanese Version of the Addenbrooke's Cognitive Examination-Revised

    PubMed Central

    dos Santos Kawata, Kelssy Hitomi; Hashimoto, Ryusaku; Nishio, Yoshiyuki; Hayashi, Atsuko; Ogawa, Nanayo; Kanno, Shigenori; Hiraoka, Kotaro; Yokoi, Kayoko; Iizuka, Osamu; Mori, Etsuro

    2012-01-01

    The aim of this study was to validate the Japanese version of the Addenbrooke's Cognitive Examination-Revised (ACE-R) [Mori: Japanese Edition of Hodges JR's Cognitive Assessment for Clinicians, 2010] designed to detect dementia, and to compare its diagnostic accuracy with that of the Mini-Mental State Examination. The ACE-R was administered to 85 healthy individuals and 126 patients with dementia. The reliability assessment revealed a strong correlation in both groups. The internal consistency was excellent (α-coefficient = 0.88). Correlation with the Clinical Dementia Rating sum of boxes score was significant (rs = −0.61, p < 0.001). The area under the curve was 0.98 for the ACE-R and 0.96 for the Mini-Mental State Examination. The cut-off score of 80 showed a sensitivity of 94% and a specificity of 94%. Like the original ACE-R and the versions designed for other languages, the Japanese version of the ACE-R is a reliable and valid test for the detection of dementia. PMID:22619659

  5. WASP (Write a Scientific Paper) using Excel - 13: Correlation and Regression.

    PubMed

    Grech, Victor

    2018-07-01

    Correlation and regression measure the closeness of association between two continuous variables. This paper explains how to perform these tests in Microsoft Excel and their interpretation, as well as how to apply these tests dynamically using Excel's functions. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. MEASURING SPORT-SPECIFIC PHYSICAL ABILITIES IN MALE GYMNASTS: THE MEN'S GYMNASTICS FUNCTIONAL MEASUREMENT TOOL

    PubMed Central

    Kenyon, Lisa K.; Elliott, James M; Cheng, M. Samuel

    2016-01-01

    Purpose/Background Despite the availability of various field-tests for many competitive sports, a reliable and valid test specifically developed for use in men's gymnastics has not yet been developed. The Men's Gymnastics Functional Measurement Tool (MGFMT) was designed to assess sport-specific physical abilities in male competitive gymnasts. The purpose of this study was to develop the MGFMT by establishing a scoring system for individual test items and to initiate the process of establishing test-retest reliability and construct validity. Methods A total of 83 competitive male gymnasts ages 7-18 underwent testing using the MGFMT. Thirty of these subjects underwent re-testing one week later in order to assess test-retest reliability. Construct validity was assessed using a simple regression analysis between total MGFMT scores and the gymnasts’ USA-Gymnastics competitive level to calculate the coefficient of determination (r2). Test-retest reliability was analyzed using Model 1 Intraclass correlation coefficients (ICC). Statistical significance was set at the p<0.05 level. Results The relationship between total MGFMT scores and subjects’ current USA-Gymnastics competitive level was found to be good (r2 = 0.63). Reliability testing of the MGFMT composite test score showed excellent test-retest reliability over a one-week period (ICC = 0.97). Test-retest reliability of the individual component tests ranged from good to excellent (ICC = 0.75-0.97). Conclusions The results of this study provide initial support for the construct validity and test-retest reliability of the MGFMT. Level of Evidence Level 3 PMID:27999723

  7. Assessment of radiation-induced xerostomia: validation of the Italian version of the xerostomia questionnaire in head and neck cancer patients.

    PubMed

    Pellegrino, Federica; Groff, Elena; Bastiani, Luca; Fattori, Bruno; Sotti, Guido

    2015-04-01

    Xerostomia is the most common acute and late side effect of radiation treatment for head and neck cancer. Affecting taste perception, chewing, swallowing and speech, xerostomia is also the major cause of decreased quality of life. The aims of this study were to validate the Italian translation of the self-reported eight-item xerostomia questionnaire (XQ) and determine its psychometric properties in patients treated with radiotherapy for head and neck cancer. An observational cross-sectional study was conducted in the Radiotherapy Unit of the Veneto Institute of Oncology - IOV in Padua. The XQ was translated according to international guidelines and filled out by 102 patients. Construct validity was assessed using principal component analysis, internal consistency using Cronbach's α coefficient and test-retest reliability at 1-month interval using the intraclass correlation coefficient (ICC). Criterion-related validity was evaluated to compare the Italian version of XQ with the European Organization for Research and Treatment of Cancer (EORTC) Core Quality-of-Life Questionnaire (QLQ-C30) and its Head and Neck Cancer Module (QLQ-H&N35). Cronbach's α for the Italian version of XQ was strong at α = 0.93, test-retest reliability was also strong (0.79) and factor analysis confirmed that the questionnaire was one-dimensional. Criterion-related validity was excellent with high association with the EORTC QLQ-H&N35 xerostomia and sticky saliva scales. The Italian version of XQ has excellent psychometric properties and can be used to evaluate the impact of emerging radiation delivery techniques aiming at preventing xerostomia.

  8. Correlation coefficient measurement of the mode-locked laser tones using four-wave mixing.

    PubMed

    Anthur, Aravind P; Panapakkam, Vivek; Vujicic, Vidak; Merghem, Kamel; Lelarge, Francois; Ramdane, Abderrahim; Barry, Liam P

    2016-06-01

    We use four-wave mixing to measure the correlation coefficient of comb tones in a quantum-dash mode-locked laser under passive and active locked regimes. We study the uncertainty in the measurement of the correlation coefficient of the proposed method.

  9. Challenge of assessing symptoms in seriously ill intensive care unit patients: can proxy reporters help?

    PubMed

    Puntillo, Kathleen A; Neuhaus, John; Arai, Shoshana; Paul, Steven M; Gropper, Michael A; Cohen, Neal H; Miaskowski, Christine

    2012-10-01

    Determine levels of agreement among intensive care unit patients and their family members, nurses, and physicians (proxies) regarding patients' symptoms and compare levels of mean intensity (i.e., the magnitude of a symptom sensation) and distress (i.e., the degree of emotionality that a symptom engenders) of symptoms among patients and proxy reporters. Prospective study of proxy reporters of symptoms in seriously ill patients. Two intensive care units in a tertiary medical center in the Western United States. Two hundred and forty-five intensive care unit patients, 243 family members, 103 nurses, and 92 physicians. None. On the basis of the magnitude of intraclass correlation coefficients, where coefficients from .35 to .78 are considered to be appropriately robust, correlation coefficients between patients' and family members' ratings met this criterion (≥.35) for intensity in six of ten symptoms. No intensity ratings between patients and nurses had intraclass correlation coefficients >.32. Three symptoms had intensity correlation coefficients of ≥.36 between patients' and physicians' ratings. Correlation coefficients between patients and family members were >.40 for five symptom-distress ratings. No symptoms had distress correlation coefficients of ≥.28 between patients' and nurses' ratings. Two symptoms had symptom-distress correlation coefficients between patients' and physicians' ratings at >.39. Family members, nurses, and physicians reported higher symptom-intensity scores than patients did for 80%, 60%, and 60% of the symptoms, respectively. Family members, nurses, and physicians reported higher symptom-distress scores than patients did for 90%, 70%, and 80% of the symptoms, respectively. Patient-family intraclass correlation coefficients were sufficiently close for us to consider using family members to help assess intensive care unit patients' symptoms. Relatively low intraclass correlation coefficients between intensive care unit clinicians' and patients' symptom ratings indicate that some proxy raters overestimate whereas others underestimate patients' symptoms. Proxy overestimation of patients' symptom scores warrants further study because this may influence decisions about treating patients' symptoms.

  10. Improved model of the retardance in citric acid coated ferrofluids using stepwise regression

    NASA Astrophysics Data System (ADS)

    Lin, J. F.; Qiu, X. R.

    2017-06-01

    Citric acid (CA) coated Fe3O4 ferrofluids (FFs) have been conducted for biomedical application. The magneto-optical retardance of CA coated FFs was measured by a Stokes polarimeter. Optimization and multiple regression of retardance in FFs were executed by Taguchi method and Microsoft Excel previously, and the F value of regression model was large enough. However, the model executed by Excel was not systematic. Instead we adopted the stepwise regression to model the retardance of CA coated FFs. From the results of stepwise regression by MATLAB, the developed model had highly predictable ability owing to F of 2.55897e+7 and correlation coefficient of one. The average absolute error of predicted retardances to measured retardances was just 0.0044%. Using the genetic algorithm (GA) in MATLAB, the optimized parametric combination was determined as [4.709 0.12 39.998 70.006] corresponding to the pH of suspension, molar ratio of CA to Fe3O4, CA volume, and coating temperature. The maximum retardance was found as 31.712°, close to that obtained by evolutionary solver in Excel and a relative error of -0.013%. Above all, the stepwise regression method was successfully used to model the retardance of CA coated FFs, and the maximum global retardance was determined by the use of GA.

  11. Empirical correlations for axial dispersion coefficient and Peclet number in fixed-bed columns.

    PubMed

    Rastegar, Seyed Omid; Gu, Tingyue

    2017-03-24

    In this work, a new correlation for the axial dispersion coefficient was obtained using experimental data in the literature for axial dispersion in fixed-bed columns packed with particles. The Chung and Wen correlation, the De Ligny correlation are two popular empirical correlations. However, the former lacks the molecular diffusion term and the latter does not consider bed voidage. The new axial dispersion coefficient correlation in this work was based on additional experimental data in the literature by considering both molecular diffusion and bed voidage. It is more comprehensive and accurate. The Peclet number correlation from the new axial dispersion coefficient correlation on the average leads to 12% lower Peclet number values compared to the values from the Chung and Wen correlation, and in many cases much smaller than those from the De Ligny correlation. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Stylus/tablet user input device for MRI heart wall segmentation: efficiency and ease of use.

    PubMed

    Taslakian, Bedros; Pires, Antonio; Halpern, Dan; Babb, James S; Axel, Leon

    2018-05-02

    To determine whether use of a stylus user input device (UID) would be superior to a mouse for CMR segmentation. Twenty-five consecutive clinical cardiac magnetic resonance (CMR) examinations were selected. Image analysis was independently performed by four observers. Manual tracing of left (LV) and right (RV) ventricular endocardial contours was performed twice in 10 randomly assigned sessions, each session using only one UID. Segmentation time and the ventricular function variables were recorded. The mean segmentation time and time reduction were calculated for each method. Intraclass correlation coefficients (ICC) and Bland-Altman plots of function variables were used to assess intra- and interobserver variability and agreement between methods. Observers completed a Likert-type questionnaire. The mean segmentation time (in seconds) was significantly less with the stylus compared to the mouse, averaging 206±108 versus 308±125 (p<0.001) and 225±140 versus 353±162 (p<0.001) for LV and RV segmentation, respectively. The intra- and interobserver agreement rates were excellent (ICC≥0.75) regardless of the UID. There was an excellent agreement between measurements derived from manual segmentation using different UIDs (ICC≥0.75), with few exceptions. Observers preferred the stylus. The study shows a significant reduction in segmentation time using the stylus, a subjective preference, and excellent agreement between the methods. • Using a stylus for MRI ventricular segmentation is faster compared to mouse • A stylus is easier to use and results in less fatigue • There is excellent agreement between stylus and mouse UIDs.

  13. Testing the Difference of Correlated Agreement Coefficients for Statistical Significance

    ERIC Educational Resources Information Center

    Gwet, Kilem L.

    2016-01-01

    This article addresses the problem of testing the difference between two correlated agreement coefficients for statistical significance. A number of authors have proposed methods for testing the difference between two correlated kappa coefficients, which require either the use of resampling methods or the use of advanced statistical modeling…

  14. Correlation of apparent diffusion coefficient ratio on 3.0 T MRI with prostate cancer Gleason score.

    PubMed

    Jyoti, Rajeev; Jain, Tarun Pankaj; Haxhimolla, Hodo; Liddell, Heath; Barrett, Sean Edward

    2018-01-01

    The purpose was to investigate the usefulness of ADC ratio on Diffusion MRI to discriminate between benign and malignant lesions of Prostate. Images of patients who underwent in-gantry MRI guided prostate lesion biopsy were retrospectively analyzed. Prostate Cancers with 20% or more Gleason score (GS) pattern 3 + 3 = 6 in each core or any volume of higher Gleason score pattern were included. ADC ratio was calculated by two reviewers for each lesion. The ADC ratio was calculated for each lesion by dividing the lowest ADC value in a lesion and highest ADC value in normal prostate in peripheral zone (PZ). ADC ratio values were compared with the biopsy result. Data was analysed using independent samples T-test, Spearman correlation, intra-class correlation coefficient (ICC) and Receiver operating characteristic (ROC) curve. 45 lesions in 33 patients were analyzed. 12 lesions were in transitional zone (TZ) and 33 in perpheral zone PZ. All lesions demonstrated an ADC ratio of 0.45 or lower. GS demonstrated a negative correlation with both the ADC value and ADC ratio . However, ADC ratio (p < 0.001) demonstrated a stronger correlation compared to ADC value alone (p = 0.014). There was no significant statistical difference between GS 3 + 4 and GS 4 + 3 mean ADC tumour value (p = 0.167). However when using ADC ratio , there was a significant difference (p = 0.032). ROC curve analysis demonstrated an area under the curve of 0.83 using ADC ratio and 0.76 when using ADC tumour value when discriminating Gleason 6 from Gleason ≥7 tumours. Inter-observer reliability in the calculation of ADC ratios was excellent, with ICC of 0.964. ADC ratio is a reliable and reproducible tool in quantification of diffusion restriction for clinically significant prostate cancer foci.

  15. Evaluation of the Microsemi CRP, an automated hematology analyzer for rapid 3-part WBC differential and CRP using whole blood.

    PubMed

    Nomura, N; Saito, K; Ikeda, M; Yuasa, S; Pastore, M; Chabert, C; Kono, E; Sakai, A; Tanaka, H; Ikemoto, T; Takubo, T

    2015-08-01

    We evaluated the basic performance of Microsemi CRP, an unique automated hematology analyzer which can simultaneously measure CBC including 3-part WBC differential (3-Diff) and CRP using whole blood treated with EDTA-2K anticoagulant. We found that it produced generally the acceptable results for all parameters performed (repeatability, reproducibility, linearity, interference effect, carry over, and correlation) using control materials, fresh human whole bloods, and serum samples. CBC data examined using Microsemi CRP showed the good correlation with the previous model, Micros CRP200 (r ≧ 0.9), and also those obtained using the routine analyzer, ADVIA 2120i (r ≧ 0.989). Concerning the 3-Diff, both GRA (%) and LYM (%) showed the excellent correlation coefficient between Microsemi CRP and Micros CRP200 (r ≧ 0.992) as well as ADVIA 2120i (r ≧ 0.957). MON (%) showed good correlation between Microsemi CRP and Micros CRP200 (r = 0.959), but lower correlation between Microsemi CRP and ADVIA 2120 i (r = 0.471). CRP data showed the good correlation with HITACHI7600 (r ≧ 0.997) and Micros CRP200 (r ≧ 0.997). From these findings, we concluded that Microsemi CRP seemed the convenient laboratory analyzer in the setting of point of care testing (POCT) especially at NICU or primary care unit. © 2014 John Wiley & Sons Ltd.

  16. Estimating Seven Coefficients of Pairwise Relatedness Using Population-Genomic Data

    PubMed Central

    Ackerman, Matthew S.; Johri, Parul; Spitze, Ken; Xu, Sen; Doak, Thomas G.; Young, Kimberly; Lynch, Michael

    2017-01-01

    Population structure can be described by genotypic-correlation coefficients between groups of individuals, the most basic of which are the pairwise relatedness coefficients between any two individuals. There are nine pairwise relatedness coefficients in the most general model, and we show that these can be reduced to seven coefficients for biallelic loci. Although all nine coefficients can be estimated from pedigrees, six coefficients have been beyond empirical reach. We provide a numerical optimization procedure that estimates all seven reduced coefficients from population-genomic data. Simulations show that the procedure is nearly unbiased, even at 3× coverage, and errors in five of the seven coefficients are statistically uncorrelated. The remaining two coefficients have a negative correlation of errors, but their sum provides an unbiased assessment of the overall correlation of heterozygosity between two individuals. Application of these new methods to four populations of the freshwater crustacean Daphnia pulex reveal the occurrence of half siblings in our samples, as well as a number of identical individuals that are likely obligately asexual clone mates. Statistically significant negative estimates of these pairwise relatedness coefficients, including inbreeding coefficients that were typically negative, underscore the difficulties that arise when interpreting genotypic correlations as estimations of the probability that alleles are identical by descent. PMID:28341647

  17. Extrapolating MP2 and CCSD explicitly correlated correlation energies to the complete basis set limit with first and second row correlation consistent basis sets

    NASA Astrophysics Data System (ADS)

    Hill, J. Grant; Peterson, Kirk A.; Knizia, Gerald; Werner, Hans-Joachim

    2009-11-01

    Accurate extrapolation to the complete basis set (CBS) limit of valence correlation energies calculated with explicitly correlated MP2-F12 and CCSD(T)-F12b methods have been investigated using a Schwenke-style approach for molecules containing both first and second row atoms. Extrapolation coefficients that are optimal for molecular systems containing first row elements differ from those optimized for second row analogs, hence values optimized for a combined set of first and second row systems are also presented. The new coefficients are shown to produce excellent results in both Schwenke-style and equivalent power-law-based two-point CBS extrapolations, with the MP2-F12/cc-pV(D,T)Z-F12 extrapolations producing an average error of just 0.17 mEh with a maximum error of 0.49 for a collection of 23 small molecules. The use of larger basis sets, i.e., cc-pV(T,Q)Z-F12 and aug-cc-pV(Q,5)Z, in extrapolations of the MP2-F12 correlation energy leads to average errors that are smaller than the degree of confidence in the reference data (˜0.1 mEh). The latter were obtained through use of very large basis sets in MP2-F12 calculations on small molecules containing both first and second row elements. CBS limits obtained from optimized coefficients for conventional MP2 are only comparable to the accuracy of the MP2-F12/cc-pV(D,T)Z-F12 extrapolation when the aug-cc-pV(5+d)Z and aug-cc-pV(6+d)Z basis sets are used. The CCSD(T)-F12b correlation energy is extrapolated as two distinct parts: CCSD-F12b and (T). While the CCSD-F12b extrapolations with smaller basis sets are statistically less accurate than those of the MP2-F12 correlation energies, this is presumably due to the slower basis set convergence of the CCSD-F12b method compared to MP2-F12. The use of larger basis sets in the CCSD-F12b extrapolations produces correlation energies with accuracies exceeding the confidence in the reference data (also obtained in large basis set F12 calculations). It is demonstrated that the use of the 3C(D) Ansatz is preferred for MP2-F12 CBS extrapolations. Optimal values of the geminal Slater exponent are presented for the diagonal, fixed amplitude Ansatz in MP2-F12 calculations, and these are also recommended for CCSD-F12b calculations.

  18. Attenuation of the Squared Canonical Correlation Coefficient under Varying Estimates of Score Reliability

    ERIC Educational Resources Information Center

    Wilson, Celia M.

    2010-01-01

    Research pertaining to the distortion of the squared canonical correlation coefficient has traditionally been limited to the effects of sampling error and associated correction formulas. The purpose of this study was to compare the degree of attenuation of the squared canonical correlation coefficient under varying conditions of score reliability.…

  19. Thin and Slow Smoke Detection by Using Frequency Image

    NASA Astrophysics Data System (ADS)

    Zheng, Guang; Oe, Shunitiro

    In this paper, a new method to detect thin and slow smoke for early fire alarm by using frequency image has been proposed. The correlation coefficient of the frequency image between the current stage and the initial stage are calculated, so are the gray image correlation coefficient of the color image. When the thin smoke close to transparent enters into the camera view, the correlation coefficient of the frequency image becomes small, while the gray image correlation coefficient of the color image hardly change and keep large. When something which is not transparent, like human beings, etc., enters into the camera view, the correlation coefficient of the frequency image becomes small, as well as that of color image. Based on the difference of correlation coefficient between frequency image and color image in different situations, the thin smoke can be detected. Also, considering the movement of the thin smoke, miss detection caused by the illustration change or noise can be avoided. Several experiments in different situations are carried out, and the experimental results show the effect of the proposed method.

  20. Statistical Study of Turbulence: Spectral Functions and Correlation Coefficients

    NASA Technical Reports Server (NTRS)

    Frenkiel, Francois N.

    1958-01-01

    In reading the publications on turbulence of different authors, one often runs the risk of confusing the various correlation coefficients and turbulence spectra. We have made a point of defining, by appropriate concepts, the differences which exist between these functions. Besides, we introduce in the symbols a few new characteristics of turbulence. In the first chapter, we study some relations between the correlation coefficients and the different turbulence spectra. Certain relations are given by means of demonstrations which could be called intuitive rather than mathematical. In this way we demonstrate that the correlation coefficients between the simultaneous turbulent velocities at two points are identical, whether studied in Lagrange's or in Euler's systems. We then consider new spectra of turbulence, obtained by study of the simultaneous velocities along a straight line of given direction. We determine some relations between these spectra and the correlation coefficients. Examining the relation between the spectrum of the turbulence measured at a fixed point and the longitudinal-correlation curve given by G. I. Taylor, we find that this equation is exact only when the coefficient is very small.

  1. Reliability and validity of simplified Chinese version of Swiss Spinal Stenosis Questionnaire for patients with degenerative lumbar spinal stenosis.

    PubMed

    Yi, Honglei; Wei, Xianzhao; Zhang, Wei; Chen, Ziqiang; Wang, Xinhui; Ji, Xinran; Zhu, Xiaodong; Wang, Fei; Xu, Ximing; Li, Zhikun; Fan, Jianping; Wang, Chuanfeng; Chen, Kai; Zhang, Guoyou; Zhao, Yinchuan; Li, Ming

    2014-05-01

    This was a prospective clinical validation study. To evaluate the reliability and validity of the adapted simplified Chinese version of Swiss Spinal Stenosis (SC-SSS) Questionnaire. The SSS Questionnaire is a reliable and valid instrument to assess the perception of function and pain for patients with degenerative lumbar spinal stenosis. However, there is no culturally adapted SSS Questionnaire for use in mainland China. This was a prospective clinical validation study. The adaption was conducted according to International Quality of Life Assessment Project guidelines. To examine the psychometric properties of the adapted SC-SSS Questionnaire, a sample of 105 patients with lumbar spinal stenosis were included. Thirty-two patients were randomly selected to evaluate the test-retest reliability. Reliability assessment of the SC-SSS Questionnaire was determined by calculating Cronbach α and intraclass coefficient values. Concurrent validity was assessed by correlating SC-SSS Questionnaire scores with relevant domains of the 36-Item Short Form Health Survey. Cronbach α of the symptom severity scale, physical function scale, patients, and satisfaction scale of SC-SSS Questionnaire are 0.89, 0.86, 0.91, respectively, which revealed very good internal consistency. The test-retest reproducibility was found to be excellent with the intraclass correlation coefficient of 0.93, 0.91, and 0.95. In terms of concurrent validity, SC-SSS Questionnaire had good correlation with physical functioning and bodily pain of 36-Item Short Form Health Survey (r = 0.663, 0.653) and low correlation with mental health (r = 0.289). The physical function scale had good correlation with physical functioning of 36-Item Short Form Health Survey (r = 0.637), whereas the rest had moderate correlation. The satisfaction scale score was highly correlated with the change in the symptom severity (r = 0.71) and physical function (r = 0.68) scale score. The SC-SSS Questionnaire showed satisfactory reliability and validity in the evaluation of functionality in patients with lumbar spinal stenosis who are experiencing neurogenic claudication. It is simple and easy to use and can be recommended in clinical and research practice in mainland China. 3.

  2. MRI-determined liver proton density fat fraction, with MRS validation: Comparison of regions of interest sampling methods in patients with type 2 diabetes.

    PubMed

    Vu, Kim-Nhien; Gilbert, Guillaume; Chalut, Marianne; Chagnon, Miguel; Chartrand, Gabriel; Tang, An

    2016-05-01

    To assess the agreement between published magnetic resonance imaging (MRI)-based regions of interest (ROI) sampling methods using liver mean proton density fat fraction (PDFF) as the reference standard. This retrospective, internal review board-approved study was conducted in 35 patients with type 2 diabetes. Liver PDFF was measured by magnetic resonance spectroscopy (MRS) using a stimulated-echo acquisition mode sequence and MRI using a multiecho spoiled gradient-recalled echo sequence at 3.0T. ROI sampling methods reported in the literature were reproduced and liver mean PDFF obtained by whole-liver segmentation was used as the reference standard. Intraclass correlation coefficients (ICCs), Bland-Altman analysis, repeated-measures analysis of variance (ANOVA), and paired t-tests were performed. ICC between MRS and MRI-PDFF was 0.916. Bland-Altman analysis showed excellent intermethod agreement with a bias of -1.5 ± 2.8%. The repeated-measures ANOVA found no systematic variation of PDFF among the nine liver segments. The correlation between liver mean PDFF and ROI sampling methods was very good to excellent (0.873 to 0.975). Paired t-tests revealed significant differences (P < 0.05) with ROI sampling methods that exclusively or predominantly sampled the right lobe. Significant correlations with mean PDFF were found with sampling methods that included higher number of segments, total area equal or larger than 5 cm(2) , or sampled both lobes (P = 0.001, 0.023, and 0.002, respectively). MRI-PDFF quantification methods should sample each liver segment in both lobes and include a total surface area equal or larger than 5 cm(2) to provide a close estimate of the liver mean PDFF. © 2015 Wiley Periodicals, Inc.

  3. Comparison between electromagnetic transponders and radiographic imaging for prostate localization: A pelvic phantom study with rotations and translations.

    PubMed

    Hamilton, Daniel G; McKenzie, Dean P; Perkins, Anne E

    2017-09-01

    The aim of this study was to evaluate the differences in target localization between Calypso ® , kV orthogonal imaging and cone-beam computed tomography (CBCT) for combined translations and rotations of an anthropomorphic pelvic phantom. The phantom was localized using all three systems in 50 different positions, with applied translational and rotational offsets randomly sampled from representative normal distributions of prostate motion. Lin's concordance correlation coefficient (ρc) and 95% confidence intervals were calculated to assess the agreement between the localization systems. Mean differences and difference vectors between the three systems were also calculated. Agreement between systems for lateral, vertical, and longitudinal translations was excellent, with ρc values of greater than 0.98 between all three systems in all axes. There was excellent agreement between the systems for rotations around the lateral axis (pitch) (ρc > 0.99), and around the vertical axis (yaw) (ρc > 0.97). However, somewhat poorer agreement for rotations around the longitudinal axis (roll) was observed, with the lowest correlation observed between Calypso and kV orthogonal imaging (ρc = 0.895). Mean differences between the phantom position reported by Calypso and the radiographic systems were less than 1 mm and 1° for all translations and rotations. The results for translations are consistent with the publications of previous authors. There is no comparable published data for rotations. While there is lower correlation between the three systems for roll than for the other angles, the mean differences in reported rotations are not clinically significant. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  4. Assessment of abdominal muscle function using the Biodex System-4. Validity and reliability in healthy volunteers and patients with giant ventral hernia.

    PubMed

    Gunnarsson, U; Johansson, M; Strigård, K

    2011-08-01

    The decrease in recurrence rates in ventral hernia surgery have led to a redirection of focus towards other important patient-related endpoints. One such endpoint is abdominal wall function. The aim of the present study was to evaluate the reliability and external validity of abdominal wall strength measurement using the Biodex System-4 with a back abdomen unit. Ten healthy volunteers and ten patients with ventral hernias exceeding 10 cm were recruited. Test-retest reliability, both with and without girdle, was evaluated by comparison of measurements at two test occasions 1 week apart. Reliability was calculated by the interclass correlation coefficients (ICC) method. Validity was evaluated by correlation with the well-established International Physical Activity Questionnaire (IPAQ) and a self-assessment of abdominal wall strength. One person in the healthy group was excluded after the first test due to neck problems following minor trauma. The reliability was excellent (>0.75), with ICC values between 0.92 and 0.97 for the different modalities tested. No differences were seen between testing with and without a girdle. Validity was also excellent both when calculated as correlation to self-assessment of abdominal wall strength, and to IPAQ, giving Kendall tau values of 0.51 and 0.47, respectively, and corresponding P values of 0.002 and 0.004. Measurement of abdominal muscle function using the Biodex System-4 is a reliable and valid method to assess this important patient-related endpoint. Further investigations will be made to explore the potential of this technique in the evaluation of the results of ventral hernia surgery, and to compare muscle function after different abdominal wall reconstruction techniques.

  5. Clinical value of patient-specific three-dimensional printing of congenital heart disease: Quantitative and qualitative assessments

    PubMed Central

    Lau, Ivan Wen Wen; Liu, Dongting; Xu, Lei; Fan, Zhanming

    2018-01-01

    Objective Current diagnostic assessment tools remain suboptimal in demonstrating complex morphology of congenital heart disease (CHD). This limitation has posed several challenges in preoperative planning, communication in medical practice, and medical education. This study aims to investigate the dimensional accuracy and the clinical value of 3D printed model of CHD in the above three areas. Methods Using cardiac computed tomography angiography (CCTA) data, a patient-specific 3D model of a 20-month-old boy with double outlet right ventricle was printed in Tango Plus material. Pearson correlation coefficient was used to evaluate correlation of the quantitative measurements taken at analogous anatomical locations between the CCTA images pre- and post-3D printing. Qualitative analysis was conducted by distributing surveys to six health professionals (two radiologists, two cardiologists and two cardiac surgeons) and three medical academics to assess the clinical value of the 3D printed model in these three areas. Results Excellent correlation (r = 0.99) was noted in the measurements between CCTA and 3D printed model, with a mean difference of 0.23 mm. Four out of six health professionals found the model to be useful in facilitating preoperative planning, while all of them thought that the model would be invaluable in enhancing patient-doctor communication. All three medical academics found the model to be helpful in teaching, and thought that the students will be able to learn the pathology quicker with better understanding. Conclusion The complex cardiac anatomy can be accurately replicated in flexible material using 3D printing technology. 3D printed heart models could serve as an excellent tool in facilitating preoperative planning, communication in medical practice, and medical education, although further studies with inclusion of more clinical cases are needed. PMID:29561912

  6. Colometer: a real-time quality feedback system for screening colonoscopy.

    PubMed

    Filip, Dobromir; Gao, Xuexin; Angulo-Rodríguez, Leticia; Mintchev, Martin P; Devlin, Shane M; Rostom, Alaa; Rosen, Wayne; Andrews, Christopher N

    2012-08-28

    To investigate the performance of a new software-based colonoscopy quality assessment system. The software-based system employs a novel image processing algorithm which detects the levels of image clarity, withdrawal velocity, and level of the bowel preparation in a real-time fashion from live video signal. Threshold levels of image blurriness and the withdrawal velocity below which the visualization could be considered adequate have initially been determined arbitrarily by review of sample colonoscopy videos by two experienced endoscopists. Subsequently, an overall colonoscopy quality rating was computed based on the percentage of the withdrawal time with adequate visualization (scored 1-5; 1, when the percentage was 1%-20%; 2, when the percentage was 21%-40%, etc.). In order to test the proposed velocity and blurriness thresholds, screening colonoscopy withdrawal videos from a specialized ambulatory colon cancer screening center were collected, automatically processed and rated. Quality ratings on the withdrawal were compared to the insertion in the same patients. Then, 3 experienced endoscopists reviewed the collected videos in a blinded fashion and rated the overall quality of each withdrawal (scored 1-5; 1, poor; 3, average; 5, excellent) based on 3 major aspects: image quality, colon preparation, and withdrawal velocity. The automated quality ratings were compared to the averaged endoscopist quality ratings using Spearman correlation coefficient. Fourteen screening colonoscopies were assessed. Adenomatous polyps were detected in 4/14 (29%) of the collected colonoscopy video samples. As a proof of concept, the Colometer software rated colonoscope withdrawal as having better visualization than the insertion in the 10 videos which did not have any polyps (average percent time with adequate visualization: 79% ± 5% for withdrawal and 50% ± 14% for insertion, P < 0.01). Withdrawal times during which no polyps were removed ranged from 4-12 min. The median quality rating from the automated system and the reviewers was 3.45 [interquartile range (IQR), 3.1-3.68] and 3.00 (IQR, 2.33-3.67) respectively for all colonoscopy video samples. The automated rating revealed a strong correlation with the reviewer's rating (ρ coefficient= 0.65, P = 0.01). There was good correlation of the automated overall quality rating and the mean endoscopist withdrawal speed rating (Spearman r coefficient= 0.59, P = 0.03). There was no correlation of automated overall quality rating with mean endoscopists image quality rating (Spearman r coefficient= 0.41, P = 0.15). The results from a novel automated real-time colonoscopy quality feedback system strongly agreed with the endoscopists' quality assessments. Further study is required to validate this approach.

  7. [Electroencephalogram Feature Selection Based on Correlation Coefficient Analysis].

    PubMed

    Zhou, Jinzhi; Tang, Xiaofang

    2015-08-01

    In order to improve the accuracy of classification with small amount of motor imagery training data on the development of brain-computer interface (BCD systems, we proposed an analyzing method to automatically select the characteristic parameters based on correlation coefficient analysis. Throughout the five sample data of dataset IV a from 2005 BCI Competition, we utilized short-time Fourier transform (STFT) and correlation coefficient calculation to reduce the number of primitive electroencephalogram dimension, then introduced feature extraction based on common spatial pattern (CSP) and classified by linear discriminant analysis (LDA). Simulation results showed that the average rate of classification accuracy could be improved by using correlation coefficient feature selection method than those without using this algorithm. Comparing with support vector machine (SVM) optimization features algorithm, the correlation coefficient analysis can lead better selection parameters to improve the accuracy of classification.

  8. A highly selective chemiluminescent probe for the detection of chromium(VI)

    NASA Astrophysics Data System (ADS)

    Jin, Yan; Sun, Yonghua; Li, Chongying; Yang, Chao

    2018-03-01

    In present work, rhodamine B hydrazide and rhodamine 6G hydrazide were synthesized and the chemiluminescence performance has been investigated. Based on the chemiluminescence of rhodamine 6G hydrazide-chromium(VI), a selective and sensitive method for the direct detection of chromium(VI) was developed. The chemiluminescence intensity was linearly related to the concentration of chromium(VI) in the range of 2.60 × 10- 8-8.00 × 10- 6 mol/L with a correlation coefficient of r = 0.998 and a detection limit of 1.4 × 10- 8 mol/L (S/N = 3). The results indicated rhodamine 6G hydrazide was an excellent chemiluminescent probe for chromium(VI) without reduction of chromium(VI) to chromium(III). A possible mechanism of CL emission was also suggested.

  9. Fluid-structure finite-element vibrational analysis

    NASA Technical Reports Server (NTRS)

    Feng, G. C.; Kiefling, L.

    1974-01-01

    A fluid finite element has been developed for a quasi-compressible fluid. Both kinetic and potential energy are expressed as functions of nodal displacements. Thus, the formulation is similar to that used for structural elements, with the only differences being that the fluid can possess gravitational potential, and the constitutive equations for fluid contain no shear coefficients. Using this approach, structural and fluid elements can be used interchangeably in existing efficient sparse-matrix structural computer programs such as SPAR. The theoretical development of the element formulations and the relationships of the local and global coordinates are shown. Solutions of fluid slosh, liquid compressibility, and coupled fluid-shell oscillation problems which were completed using a temporary digital computer program are shown. The frequency correlation of the solutions with classical theory is excellent.

  10. Factor structure of the Bulimia Test--Revised in college women from four ethnic groups.

    PubMed

    Fernandez, Senaida; Malcarne, Vanessa L; Malacrne, Vanessa L; Wilfley, Denise E; McQuaid, John

    2006-07-01

    The factor structure of the Bulimia Test--Revised (BULIT-R) was investigated using confirmatory factor analysis (CFA) and exploratory factor analysis (EFA). The sample consisted of 2,671 female college students (African American, Asian American, Caucasian American, and Latino American). Reliability coefficients were excellent across groups. African Americans scored significantly lower on the BULIT-R than Caucasian Americans. Across groups, CFA and EFA results suggest a six-factor solution is most appropriate. Consistent across groups were factors representing bingeing, body image, purging, and extreme weight loss behaviors, while few differences were observed across groups. These findings suggest that the measure is reliable and valid for use with diverse ethnic groups. Future research should focus on culturally salient psychological correlates of disordered eating in diverse ethnic groups.

  11. The blue-to-green reflectance ratio and lake water quality

    NASA Technical Reports Server (NTRS)

    Piech, K. R.; Schott, J. R.; Stewart, K. M.

    1978-01-01

    Correlations between the relative values of the blue and green reflectances of a lake and water quality indices, such as depth of photic zone, Secchi disk transparency, attenuation coefficient, and chlorophyll concentration, have been observed during an intensive satellite, aircraft, and surface vessel study of Lake Ontario and Conesus Lake. Determinations of blue and green reflectances from Skylab S190A color imagery are in excellent agreement with values obtained from small-scale color imagery from aircraft. Further, the accuracy of the satellite data appears within that required for extrapolation to the water quality indices. The study has also determined that changes in chlorophyll, lignin, and humic acid concentration can be discriminated by the behavior of the blue-to-green reflectance ratio and the reflectances of the green and red bands.

  12. Quantifying the range of cross-correlated fluctuations using a q- L dependent AHXA coefficient

    NASA Astrophysics Data System (ADS)

    Wang, Fang; Wang, Lin; Chen, Yuming

    2018-03-01

    Recently, based on analogous height cross-correlation analysis (AHXA), a cross-correlation coefficient ρ×(L) has been proposed to quantify the levels of cross-correlation on different temporal scales for bivariate series. A limitation of this coefficient is that it cannot capture the full information of cross-correlations on amplitude of fluctuations. In fact, it only detects the cross-correlation at a specific order fluctuation, which might neglect some important information inherited from other order fluctuations. To overcome this disadvantage, in this work, based on the scaling of the qth order covariance and time delay L, we define a two-parameter dependent cross-correlation coefficient ρq(L) to detect and quantify the range and level of cross-correlations. This new version of ρq(L) coefficient leads to the formation of a ρq(L) surface, which not only is able to quantify the level of cross-correlations, but also allows us to identify the range of fluctuation amplitudes that are correlated in two given signals. Applications to the classical ARFIMA models and the binomial multifractal series illustrate the feasibility of this new coefficient ρq(L) . In addition, a statistical test is proposed to quantify the existence of cross-correlations between two given series. Applying our method to the real life empirical data from the 1999-2000 California electricity market, we find that the California power crisis in 2000 destroys the cross-correlation between the price and the load series but does not affect the correlation of the load series during and before the crisis.

  13. Quantifying colocalization by correlation: the Pearson correlation coefficient is superior to the Mander's overlap coefficient.

    PubMed

    Adler, Jeremy; Parmryd, Ingela

    2010-08-01

    The Pearson correlation coefficient (PCC) and the Mander's overlap coefficient (MOC) are used to quantify the degree of colocalization between fluorophores. The MOC was introduced to overcome perceived problems with the PCC. The two coefficients are mathematically similar, differing in the use of either the absolute intensities (MOC) or of the deviation from the mean (PCC). A range of correlated datasets, which extend to the limits of the PCC, only evoked a limited response from the MOC. The PCC is unaffected by changes to the offset while the MOC increases when the offset is positive. Both coefficients are independent of gain. The MOC is a confusing hybrid measurement, that combines correlation with a heavily weighted form of co-occurrence, favors high intensity combinations, downplays combinations in which either or both intensities are low and ignores blank pixels. The PCC only measures correlation. A surprising finding was that the addition of a second uncorrelated population can substantially increase the measured correlation, demonstrating the importance of excluding background pixels. Overall, since the MOC is unresponsive to substantial changes in the data and is hard to interpret, it is neither an alternative to nor a useful substitute for the PCC. The MOC is not suitable for making measurements of colocalization either by correlation or co-occurrence.

  14. Can Imaging Parameters Provide Information Regarding Histopathology in Head and Neck Squamous Cell Carcinoma? A Meta-Analysis.

    PubMed

    Surov, Alexey; Meyer, Hans Jonas; Wienke, Andreas

    2018-04-01

    Our purpose was to provide data regarding relationships between different imaging and histopathological parameters in HNSCC. MEDLINE library was screened for associations between different imaging parameters and histopathological features in HNSCC up to December 2017. Only papers containing correlation coefficients between different imaging parameters and histopathological findings were acquired for the analysis. Associations between 18 F-FDG positron emission tomography (PET) and KI 67 were reported in 8 studies (236 patients). The pooled correlation coefficient was 0.20 (95% CI = [-0.04; 0.44]). Furthermore, in 4 studies (64 patients), associations between 18 F-fluorothymidine PET and KI 67 were analyzed. The pooled correlation coefficient between SUV max and KI 67 was 0.28 (95% CI = [-0.06; 0.94]). In 2 studies (23 patients), relationships between KI 67 and dynamic contrast-enhanced magnetic resonance imaging were reported. The pooled correlation coefficient between K trans and KI 67 was -0.68 (95% CI = [-0.91; -0.44]). Two studies (31 patients) investigated correlation between apparent diffusion coefficient (ADC) and KI 67. The pooled correlation coefficient was -0.61 (95% CI = [-0.84; -0.38]). In 2 studies (117 patients), relationships between 18 F-FDG PET and p53 were analyzed. The pooled correlation coefficient was 0.0 (95% CI = [-0.87; 0.88]). There were 3 studies (48 patients) that investigated associations between ADC and tumor cell count in HNSCC. The pooled correlation coefficient was -0.53 (95% CI = [-0.74; -0.32]). Associations between 18 F-FDG PET and HIF-1α were investigated in 3 studies (72 patients). The pooled correlation coefficient was 0.44 (95% CI = [-0.20; 1.08]). ADC may predict cell count and proliferation activity, and SUV max may predict expression of HIF-1α in HNSCC. SUV max cannot be used as surrogate marker for expression of KI 67 and p53. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  15. A novel coefficient for detecting and quantifying asymmetry of California electricity market based on asymmetric detrended cross-correlation analysis.

    PubMed

    Wang, Fang

    2016-06-01

    In order to detect and quantify asymmetry of two time series, a novel cross-correlation coefficient is proposed based on recent asymmetric detrended cross-correlation analysis (A-DXA), which we called A-DXA coefficient. The A-DXA coefficient, as an important extension of DXA coefficient ρDXA, contains two directional asymmetric cross-correlated indexes, describing upwards and downwards asymmetric cross-correlations, respectively. By using the information of directional covariance function of two time series and directional variance function of each series itself instead of power-law between the covariance function and time scale, the proposed A-DXA coefficient can well detect asymmetry between the two series no matter whether the cross-correlation is significant or not. By means of the proposed A-DXA coefficient conducted over the asymmetry for California electricity market, we found that the asymmetry between the prices and loads is not significant for daily average data in 1999 yr market (before electricity crisis) but extremely significant for those in 2000 yr market (during the crisis). To further uncover the difference of asymmetry between the years 1999 and 2000, a modified H statistic (MH) and ΔMH statistic are proposed. One of the present contributions is that the high MH values calculated for hourly data exist in majority months in 2000 market. Another important conclusion is that the cross-correlation with downwards dominates over the whole 1999 yr in contrast to the cross-correlation with upwards dominates over the 2000 yr.

  16. Detecting PM2.5's Correlations between Neighboring Cities Using a Time-Lagged Cross-Correlation Coefficient.

    PubMed

    Wang, Fang; Wang, Lin; Chen, Yuming

    2017-08-31

    In order to investigate the time-dependent cross-correlations of fine particulate (PM2.5) series among neighboring cities in Northern China, in this paper, we propose a new cross-correlation coefficient, the time-lagged q-L dependent height crosscorrelation coefficient (denoted by p q (τ, L)), which incorporates the time-lag factor and the fluctuation amplitude information into the analogous height cross-correlation analysis coefficient. Numerical tests are performed to illustrate that the newly proposed coefficient ρ q (τ, L) can be used to detect cross-correlations between two series with time lags and to identify different range of fluctuations at which two series possess cross-correlations. Applying the new coefficient to analyze the time-dependent cross-correlations of PM2.5 series between Beijing and the three neighboring cities of Tianjin, Zhangjiakou, and Baoding, we find that time lags between the PM2.5 series with larger fluctuations are longer than those between PM2.5 series withsmaller fluctuations. Our analysis also shows that cross-correlations between the PM2.5 series of two neighboring cities are significant and the time lags between two PM2.5 series of neighboring cities are significantly non-zero. These findings providenew scientific support on the view that air pollution in neighboring cities can affect one another not simultaneously but with a time lag.

  17. Modeling visibility in the Paso del Norte (PDN) Region

    NASA Astrophysics Data System (ADS)

    Medina Calderon, Richard

    Poor visibility is a subject of growing public concern throughout the U.S, and an active area of research. Its societal impacts on air quality, aviation transport and traffic are significant. Aerosols play a fundamental role in the attenuation of solar radiation, and also affect visibility. The scattering and extinction coefficients of aerosol particles in the Paso del Norte Region have been calculated using the T- matrix model in conjunction with a laser particle counter. Inter-comparison of the model's results of the scattering and absorption coefficients against the corresponding data from a Photoacustic extinctiometer instrument (which measures in-situ absorption and scattering coefficients of aerosol particles) shows excellent agreement. In addition, the volume-weighted method is used to determine the composite index of refraction which is representative of the aerosols for the Paso del Norte Region to obtain information of the type of aerosol particles present in the Region. The Single Scattering Albedo has also been retrieved using this methodology to obtain further insight into the type of aerosols present on a given day. Finally, the Koschmieder equation has been used to calculate the visual range or visibility, and was correlated with the PM2.5 and PM10 particle concentration present in the Region. Our methodology will allow a better understanding of the size and type of aerosol particles that are most detrimental to the visibility for the Paso Del Norte Region.

  18. Estimating groundwater levels using system identification models in Nzhelele and Luvuvhu areas, Limpopo Province, South Africa

    NASA Astrophysics Data System (ADS)

    Makungo, Rachel; Odiyo, John O.

    2017-08-01

    This study was focused on testing the ability of a coupled linear and non-linear system identification model in estimating groundwater levels. System identification provides an alternative approach for estimating groundwater levels in areas that lack data required by physically-based models. It also overcomes the limitations of physically-based models due to approximations, assumptions and simplifications. Daily groundwater levels for 4 boreholes, rainfall and evaporation data covering the period 2005-2014 were used in the study. Seventy and thirty percent of the data were used to calibrate and validate the model, respectively. Correlation coefficient (R), coefficient of determination (R2), root mean square error (RMSE), percent bias (PBIAS), Nash Sutcliffe coefficient of efficiency (NSE) and graphical fits were used to evaluate the model performance. Values for R, R2, RMSE, PBIAS and NSE ranged from 0.8 to 0.99, 0.63 to 0.99, 0.01-2.06 m, -7.18 to 1.16 and 0.68 to 0.99, respectively. Comparisons of observed and simulated groundwater levels for calibration and validation runs showed close agreements. The model performance mostly varied from satisfactory, good, very good and excellent. Thus, the model is able to estimate groundwater levels. The calibrated models can reasonably capture description between input and output variables and can, thus be used to estimate long term groundwater levels.

  19. Runge-Kutta Methods for Linear Ordinary Differential Equations

    NASA Technical Reports Server (NTRS)

    Zingg, David W.; Chisholm, Todd T.

    1997-01-01

    Three new Runge-Kutta methods are presented for numerical integration of systems of linear inhomogeneous ordinary differential equations (ODES) with constant coefficients. Such ODEs arise in the numerical solution of the partial differential equations governing linear wave phenomena. The restriction to linear ODEs with constant coefficients reduces the number of conditions which the coefficients of the Runge-Kutta method must satisfy. This freedom is used to develop methods which are more efficient than conventional Runge-Kutta methods. A fourth-order method is presented which uses only two memory locations per dependent variable, while the classical fourth-order Runge-Kutta method uses three. This method is an excellent choice for simulations of linear wave phenomena if memory is a primary concern. In addition, fifth- and sixth-order methods are presented which require five and six stages, respectively, one fewer than their conventional counterparts, and are therefore more efficient. These methods are an excellent option for use with high-order spatial discretizations.

  20. HCV core-antigen assay as an alternative to HCV RNA quantification: A correlation study for the assessment of HCV viremia.

    PubMed

    Alonso, Roberto; Pérez-García, Felipe; López-Roa, Paula; Alcalá, Luis; Rodeño, Pilar; Bouza, Emilio

    2018-03-01

    Detection of hepatitis C virus (HCV) RNA and the HCV core antigen assay (HCV-Ag) are reliable techniques for the diagnosis of active and chronic HCV infection. Our aim was to evaluate the HCV-Ag assay as an alternative to quantification of HVC RNA. A comparison was made of the sensitivity and specificity of an HCV-Ag assay (204 serum samples) with those of a PCR assay, and the correlation between the two techniques was determined. The sensitivity and specificity of HCV-Ag was 76.6% and 100%, respectively. Both assays were extremely well correlated (Pearson coefficient=0.951). The formula (LogCV=1.15*LogAg+2.26) was obtained to calculate the viral load by PCR from HCV-Ag values. HCV-Ag was unable to detect viral loads below 5000IU/mL. Although the HCV-Ag assay was less sensitive than the PCR assay, the correlation between both assays was excellent. HCV-Ag can be useful as a first step in the diagnosis of acute or chronic HCV infection and in emergency situations. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  1. Limits of the memory coefficient in measuring correlated bursts

    NASA Astrophysics Data System (ADS)

    Jo, Hang-Hyun; Hiraoka, Takayuki

    2018-03-01

    Temporal inhomogeneities in event sequences of natural and social phenomena have been characterized in terms of interevent times and correlations between interevent times. The inhomogeneities of interevent times have been extensively studied, while the correlations between interevent times, often called correlated bursts, are far from being fully understood. For measuring the correlated bursts, two relevant approaches were suggested, i.e., memory coefficient and burst size distribution. Here a burst size denotes the number of events in a bursty train detected for a given time window. Empirical analyses have revealed that the larger memory coefficient tends to be associated with the heavier tail of the burst size distribution. In particular, empirical findings in human activities appear inconsistent, such that the memory coefficient is close to 0, while burst size distributions follow a power law. In order to comprehend these observations, by assuming the conditional independence between consecutive interevent times, we derive the analytical form of the memory coefficient as a function of parameters describing interevent time and burst size distributions. Our analytical result can explain the general tendency of the larger memory coefficient being associated with the heavier tail of burst size distribution. We also find that the apparently inconsistent observations in human activities are compatible with each other, indicating that the memory coefficient has limits to measure the correlated bursts.

  2. The premature ejaculation diagnostic tool (PEDT): linguistic validity of the Chinese version.

    PubMed

    Huang, Yan-Ping; Chen, Bin; Ping, Ping; Wang, Hong-Xiang; Hu, Kai; Zhang, Tao; Yang, Hao; Jin, Yan; Yang, Qi; Huang, Yi-Ran

    2014-09-01

    The premature ejaculation diagnostic tool (PEDT) was developed to standardize the diagnosis of PE and has been applied in many countries. However, a linguistic validation of the Chinese version of PEDT does not exist. This study aims to undertake the Chinese validation of the PEDT and to evaluate its association with self-estimated intravaginal ejaculatory latency time (IELT) and clinical expert diagnosis of PE. A Chinese version of PEDT was confirmed by andrologist and bilingual linguist. Participants were recruited among seven different communities of Shanghai from 2011 to 2012, and their information regarding self-reported PE, self-estimated IELT, expert diagnosis of PE, and PEDT scores were collected. Validity of the PEDT and its association with clinical expert diagnosis of PE and self-estimated IELT were analyzed. A total of 143 patients without PE (mean age 55.11 ± 7.65 years) and 100 men with PE (mean age 53.07 ± 8.08 years) were enrolled for validation. Of the patients in PE group, the number of men reporting self-estimated IELTs of ≤1, 1-2, and >2 minutes were 34 (34.0%), 22 (22.0%), and 44 (44.0%), respectively. The Cronbach's alpha score (α = 0.77) showed adequate internal consistency, and the test-retest correlation coefficients of each item (r ≥ 0.70, P < 0.001) indicated excellent stability over time. The frequency of agreement showed that there was excellent concordance between PEDT diagnosis and clinician diagnosis when the PEDT scores ≥11. An adequate correlation was found between total PEDT score and self-estimated IELT (ρ = -0.396, P < 0.001), and sensitivity and specificity analyses suggested a score of ≤8 indicated no time-defined PE (self-estimated IELT ≤1 minute). The Chinese version of PEDT is valid in screening the presence of PE among Chinese men. The PEDT showed an adequate negative correlation with self-estimated IELT and an excellent concordance with clinician diagnosis of PE. © 2014 International Society for Sexual Medicine.

  3. Correlation Coefficients: Appropriate Use and Interpretation.

    PubMed

    Schober, Patrick; Boer, Christa; Schwarte, Lothar A

    2018-05-01

    Correlation in the broadest sense is a measure of an association between variables. In correlated data, the change in the magnitude of 1 variable is associated with a change in the magnitude of another variable, either in the same (positive correlation) or in the opposite (negative correlation) direction. Most often, the term correlation is used in the context of a linear relationship between 2 continuous variables and expressed as Pearson product-moment correlation. The Pearson correlation coefficient is typically used for jointly normally distributed data (data that follow a bivariate normal distribution). For nonnormally distributed continuous data, for ordinal data, or for data with relevant outliers, a Spearman rank correlation can be used as a measure of a monotonic association. Both correlation coefficients are scaled such that they range from -1 to +1, where 0 indicates that there is no linear or monotonic association, and the relationship gets stronger and ultimately approaches a straight line (Pearson correlation) or a constantly increasing or decreasing curve (Spearman correlation) as the coefficient approaches an absolute value of 1. Hypothesis tests and confidence intervals can be used to address the statistical significance of the results and to estimate the strength of the relationship in the population from which the data were sampled. The aim of this tutorial is to guide researchers and clinicians in the appropriate use and interpretation of correlation coefficients.

  4. A Structured Clinical Interview for Kleptomania (SCI-K): preliminary validity and reliability testing.

    PubMed

    Grant, Jon E; Kim, Suck Won; McCabe, James S

    2006-06-01

    Kleptomania presents difficulties in diagnosis for clinicians. This study aimed to develop and test a DSM-IV-based diagnostic instrument for kleptomania. To assess for current kleptomania the Structured Clinical Interview for Kleptomania (SCI-K) was administered to 112 consecutive subjects requesting psychiatric outpatient treatment for a variety of disorders. Reliability and validity were determined. Classification accuracy was examined using the longitudinal course of illness. The SCI-K demonstrated excellent test-retest (Phi coefficient = 0.956 (95% CI = 0.937, 0.970)) and inter-rater reliability (phi coefficient = 0.718 (95% CI = 0.506, 0.848)) in the diagnosis of kleptomania. Concurrent validity was observed with a self-report measure using DSM-IV kleptomania criteria (phi coefficient = 0.769 (95% CI = 0.653, 0.850)). Discriminant validity was observed with a measure of depression (point biserial coefficient = -0.020 (95% CI = -0.205, 0.166)). The SCI-K demonstrated both high sensitivity and specificity based on longitudinal assessment. The SCI-K demonstrated excellent reliability and validity in diagnosing kleptomania in subjects presenting with various psychiatric problems. These findings require replication in larger groups, including non-psychiatric populations, to examine their generalizability. Copyright (c) 2006 John Wiley & Sons, Ltd.

  5. The reliability and convergent and divergent validity of the Ruff Figural Fluency Test in healthy young adults.

    PubMed

    Ross, Thomas P

    2014-12-01

    The reliability and validity of standard and qualitative scores for the Ruff Figural Fluency Test (RFFT; Ruff, 1988) was examined in 102 healthy undergraduates. Participants (M age = 21.79; SD = 3.7; age = 80% Caucasian) were administered the RFFT and measures assessing executive functions (EF) and other cognitive domains. Inter-scorer reliability was excellent (0.9 range) for most RFFT indices. Test-retest coefficients (M interval = 7 weeks) ranged from 0.64 for the error ratio score to 0.87 for unique designs. RFFT indices correlated with Block Design performance and nonverbal measures of working memory, but were unrelated to measures of verbal fluency, verbal learning, or working memory for verbal material. RFFT novel design output correlated with most measures of EF supporting the convergent validity of this measure. In contrast, correlations between measures of EF and qualitative scores were absent or weak. RFFT score interpretation is discussed in light of relevant models of EF and directions for future research are presented. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Results of correlations for transition location on a clean-up glove installed on an F-14 aircraft and design studies for a laminar glove for the X-29 aircraft accounting for spanwise pressure gradient

    NASA Technical Reports Server (NTRS)

    Goradia, S. H.; Bobbitt, P. J.; Morgan, H. L.; Ferris, J. C.; Harvey, William D.

    1989-01-01

    Results of correlative and design studies for transition location, laminar and turbulent boundary-layer parameters, and wake drag for forward swept and aft swept wings are presented. These studies were performed with the use of an improved integral-type boundary-layer and transition-prediction methods. Theoretical predictions were compared with flight measurements at subsonic and transonic flow conditions for the variable aft swept wing F-14 aircraft for which experimental pressure distributions, transition locations, and turbulent boundary-layer velocity profiles were measured. Flight data were available at three spanwise stations for several values of sweep, freestream unit Reynolds number, Mach numbers, and lift coefficients. Theory/experiment correlations indicate excellent agreement for both transition location and turbulent boundary-layer parameters. The results of parametric studies performed during the design of a laminar glove for the forward swept wing X-29 aircraft are also presented. These studies include the effects of a spanwise pressure gradient on transition location and wake drag for several values of freestream Reynolds numbers at a freestream Mach number of 0.9.

  7. Random spot urine protein to creatinine ratio is a reliable measure of proteinuria in lupus nephritis in Koreans.

    PubMed

    Choi, In Ah; Park, Jin Kyun; Lee, Eun Young; Song, Yeong Wook; Lee, Eun Bong

    2013-01-01

    The accurate assessment of proteinuria is critical for the management of lupus nephritis. Measuring the protein to creatinine (P/C) ratio in random spot urine (RSU) samples has been introduced as an alternative to the 24-hour (24h) urine collection method. However, it remains unclear as to whether the RSU P/C ratio is reliable for assessing lupus nephritis (LN) in routine clinical practice. In total, 275 pairs of 24h urine and RSU samples from 102 patients with biopsy-proven LN were analysed. The correlation and concordance between the P/C ratios in the two sample types were assessed by Pearson or Spearman correlation and intra-class correlation coefficient (ICC) using mixed models for repeated measurements, respectively. The mean 24h urine P/C ratio was 3.2 ± 4.9. Overall, RSU P/C ratio correlated strongly with the 24h urine P/C ratio (r=0.944, p<0.001) with an excellent agreement (ICC=0.949, 95% confidence interval [CI]: 0.69-1.00). Subgroup analyses revealed that the correlation remained high in class II, III, IV, and V LN (rho=0.868, p<0.001; rho=0.649, p=0.007; r=0.945, p<0.001; and rho=0.900, p=0.001, respectively). The correlation between the 24h urine and RSU P/C ratio in the range of 0.5 to 3 was good (r=0.720, p<0.001) with ICC of 0.659 (95%CI 0.554-0.812). RSU P/C ratio ≥0.5 could predict 24h PCR ≥0.5 with 91.7% sensitivity and 70.2% specificity, whereas RSU P/C ratio ≥1.0 increased specificity up to 94.7%. The RSU P/C ratio is an excellent alternative to the 24 hour P/C ratio for assessing the presence of clinically significant proteinuria in LN. RSU P/C ratio >1.0 may prompt directly to a renal biopsy, whereas RSU P/C ratio between 0.5-1.0 should be followed by a confirmatory 24h urine collection.

  8. Construct validity of the Free and Cued Selective Reminding Test in older adults with memory complaints.

    PubMed

    Clerici, Francesca; Ghiretti, Roberta; Di Pucchio, Alessandra; Pomati, Simone; Cucumo, Valentina; Marcone, Alessandra; Vanacore, Nicola; Mariani, Claudio; Cappa, Stefano Francesco

    2017-06-01

    The Free and Cued Selective Reminding Test (FCSRT) is the memory test recommended by the International Working Group on Alzheimer's disease (AD) for the detection of amnestic syndrome of the medial temporal type in prodromal AD. Assessing the construct validity and internal consistency of the Italian version of the FCSRT is thus crucial. The FCSRT was administered to 338 community-dwelling participants with memory complaints (57% females, age 74.5 ± 7.7 years), including 34 with AD, 203 with Mild Cognitive Impairment, and 101 with Subjective Memory Impairment. Internal Consistency was estimated using Cronbach's alpha coefficient. To assess convergent validity, five FCSRT scores (Immediate Free Recall, Immediate Total Recall, Delayed Free Recall, Delayed Total Recall, and Index of Sensitivity of Cueing) were correlated with three well-validated memory tests: Story Recall, Rey Auditory Verbal Learning test, and Rey Complex Figure (RCF) recall (partial correlation analysis). To assess divergent validity, a principal component analysis (an exploratory factor analysis) was performed including, in addition to the above-mentioned memory tasks, the following tests: Word Fluencies, RCF copy, Clock Drawing Test, Trail Making Test, Frontal Assessment Battery, Raven Coloured Progressive Matrices, and Stroop Colour-Word Test. Cronbach's alpha coefficients for immediate recalls (IFR and ITR) and delayed recalls (DFR and DTR) were, respectively, .84 and .81. All FCSRT scores were highly correlated with those of the three well-validated memory tests. The factor analysis showed that the FCSRT does not load on the factors saturated by non-memory tests. These findings indicate that the FCSRT has a good internal consistency and has an excellent construct validity as an episodic memory measure. © 2015 The British Psychological Society.

  9. Cross-cultural Adaptation and Validation of the Medication Regimen Complexity Index Adapted to Spanish.

    PubMed

    Saez de la Fuente, Javier; Such Diaz, Ana; Cañamares-Orbis, Irene; Ramila, Estela; Izquierdo-Garcia, Elsa; Esteban, Concepcion; Escobar-Rodríguez, Ismael

    2016-11-01

    The most widely used validated instrument to assess the complexity of medication regimens is the Medication Regimen Complexity Index (MRCI). This study aimed to translate, adapt, and validate a reliable version of the MRCI adapted to Spanish (MRCI-E). The cross-cultural adaptation process consisted of an independent translation by 3 clinical pharmacists and a backtranslation by 2 native English speakers. A reliability analysis was conducted on 20 elderly randomly selected patients. Two clinical pharmacists calculated the MRCI-E from discharge treatments and 2 months later. For the validity analysis, the sample was augmented to 60 patients. Convergent validity was assessed by analyzing the correlation between the number of medications; discriminant validity was stratified by gender; and predictive validity was determined by analyzing the ability to predict readmission and mortality at 3 and 6 months. The MRCI-E retained the original structure of 3 sections. The reliability analysis demonstrated an excellent internal consistency (Cronbach's α=0.83), and the intraclass correlation coefficient exceeded 0.9 in all cases. The correlation coefficient with the number of medications was 0.883 ( P<0.001). No significant differences were found when stratified by gender (3.6; 95%CI=-2.9 to 10.2; P=0.27). Patients who were readmitted at 3 months had a higher MRCI-E score (10.7; 95%CI=4.4 to 17.2; P=0.001). The differences remained significant in patients readmitted at 6 months, but differences in mortality were not detected. The MRCI-E retains the reliability and validity of the original index and provides a suitable tool to assess the complexity of medication regimens in Spanish.

  10. Assessment of Activity of Crohn Disease by Diffusion-Weighted Magnetic Resonance Imaging

    PubMed Central

    Li, Xue-hua; Sun, Can-hui; Mao, Ren; Zhang, Zhong-wei; Jiang, Xiao-song; Pui, Margaret H.; Chen, Min-hu; Li, Zi-ping

    2015-01-01

    Abstract To assess the diagnostic efficacy of diffusion-weighted MR imaging (DWI) for evaluating inflammatory activity in patients with Crohn's disease (CD). A total of 47 CD patients underwent MR enterography (MRE) and DWI using 3 b values of 50, 400, and 800 s/mm.2 Apparent diffusion coefficients (ADCs) of inflamed and normal bowel wall were calculated. The conventional MRE findings and DWI signal intensities were qualitatively scored from 0 to 3. The correlation between Crohn disease activity index (CDAI) and both ADCs and magnetic resonance imaging scores was analyzed. Receiver-operating characteristic curve analysis was used to determine the diagnostic accuracy of CD activity. Of the 47 patients, 25 were active CD (CDAI≥150) and 22 were inactive (CDAI<150). Diffusion-weighted MR imaging and MRE + DWI scores of active CD were significantly higher than that of inactive CD (both P < 0.001). Apparent diffusion coefficients in inflamed segments of active CD were lower than that of inactive CD (P < 0.001). The DWI scores (r = 0.74, P < 0.001), ADCs (r = −0.71, P < 0.001), MRE scores (r = 0.54, P < 0.001), and MRE + DWI scores (r = 0.66, P < 0.001) were all correlated with CDAI. The areas under the receiver-operating characteristics curves for ADCs, DWI scores, MRE scores, and MRE + DWI scores ranged from 0.83 to 0.98. The threshold ADC value of 1.17 × 10−3 mm2/s allowed differentiation of active from inactive CD with 100% sensitivity and 88% specificity. Diffusion-weighted MR imaging and ADC correlated with CD activity, and had excellent diagnostic accuracy for differentiating active from inactive CD. PMID:26512584

  11. Estimating Premorbid Cognitive Abilities in Low-Educated Populations

    PubMed Central

    Apolinario, Daniel; Brucki, Sonia Maria Dozzi; Ferretti, Renata Eloah de Lucena; Farfel, José Marcelo; Magaldi, Regina Miksian; Busse, Alexandre Leopold; Jacob-Filho, Wilson

    2013-01-01

    Objective To develop an informant-based instrument that would provide a valid estimate of premorbid cognitive abilities in low-educated populations. Methods A questionnaire was drafted by focusing on the premorbid period with a 10-year time frame. The initial pool of items was submitted to classical test theory and a factorial analysis. The resulting instrument, named the Premorbid Cognitive Abilities Scale (PCAS), is composed of questions addressing educational attainment, major lifetime occupation, reading abilities, reading habits, writing abilities, calculation abilities, use of widely available technology, and the ability to search for specific information. The validation sample was composed of 132 older Brazilian adults from the following three demographically matched groups: normal cognitive aging (n = 72), mild cognitive impairment (n = 33), and mild dementia (n = 27). The scores of a reading test and a neuropsychological battery were adopted as construct criteria. Post-mortem inter-informant reliability was tested in a sub-study with two relatives from each deceased individual. Results All items presented good discriminative power, with corrected item-total correlation varying from 0.35 to 0.74. The summed score of the instrument presented high correlation coefficients with global cognitive function (r = 0.73) and reading skills (r = 0.82). Cronbach's alpha was 0.90, showing optimal internal consistency without redundancy. The scores did not decrease across the progressive levels of cognitive impairment, suggesting that the goal of evaluating the premorbid state was achieved. The intraclass correlation coefficient was 0.96, indicating excellent inter-informant reliability. Conclusion The instrument developed in this study has shown good properties and can be used as a valid estimate of premorbid cognitive abilities in low-educated populations. The applicability of the PCAS, both as an estimate of premorbid intelligence and cognitive reserve, is discussed. PMID:23555894

  12. Test–retest reliability, validity, and minimum detectable change of visual analog, numerical rating, and verbal rating scales for measurement of osteoarthritic knee pain

    PubMed Central

    Alghadir, Ahmad H; Anwer, Shahnawaz; Iqbal, Amir; Iqbal, Zaheen Ahmed

    2018-01-01

    Objective Several scales are commonly used for assessing pain intensity. Among them, the numerical rating scale (NRS), visual analog scale (VAS), and verbal rating scale (VRS) are often used in clinical practice. However, no study has performed psychometric analyses of their reliability and validity in the measurement of osteoarthritic (OA) pain. Therefore, the present study examined the test–retest reliability, validity, and minimum detectable change (MDC) of the VAS, NRS, and VRS for the measurement of OA knee pain. In addition, the correlations of VAS, NRS, and VRS with demographic variables were evaluated. Methods The study included 121 subjects (65 women, 56 men; aged 40–80 years) with OA of the knee. Test–retest reliability of the VAS, NRS, and VRS was assessed during two consecutive visits in a 24 h interval. The validity was tested using Pearson’s correlation coefficients between the baseline scores of VAS, NRS, and VRS and the demographic variables (age, body mass index [BMI], sex, and OA grade). The standard error of measurement (SEM) and the MDC were calculated to assess statistically meaningful changes. Results The intraclass correlation coefficients of the VAS, NRS, and VRS were 0.97, 0.95, and 0.93, respectively. VAS, NRS, and VRS were significantly related to demographic variables (age, BMI, sex, and OA grade). The SEM of VAS, NRS, and VRS was 0.03, 0.48, and 0.21, respectively. The MDC of VAS, NRS, and VRS was 0.08, 1.33, and 0.58, respectively. Conclusion All the three scales had excellent test–retest reliability. However, the VAS was the most reliable, with the smallest errors in the measurement of OA knee pain. PMID:29731662

  13. Digital image analysis of Ki67 proliferation index in breast cancer using virtual dual staining on whole tissue sections: clinical validation and inter-platform agreement.

    PubMed

    Koopman, Timco; Buikema, Henk J; Hollema, Harry; de Bock, Geertruida H; van der Vegt, Bert

    2018-05-01

    The Ki67 proliferation index is a prognostic and predictive marker in breast cancer. Manual scoring is prone to inter- and intra-observer variability. The aims of this study were to clinically validate digital image analysis (DIA) of Ki67 using virtual dual staining (VDS) on whole tissue sections and to assess inter-platform agreement between two independent DIA platforms. Serial whole tissue sections of 154 consecutive invasive breast carcinomas were stained for Ki67 and cytokeratin 8/18 with immunohistochemistry in a clinical setting. Ki67 proliferation index was determined using two independent DIA platforms, implementing VDS to identify tumor tissue. Manual Ki67 score was determined using a standardized manual counting protocol. Inter-observer agreement between manual and DIA scores and inter-platform agreement between both DIA platforms were determined and calculated using Spearman's correlation coefficients. Correlations and agreement were assessed with scatterplots and Bland-Altman plots. Spearman's correlation coefficients were 0.94 (p < 0.001) for inter-observer agreement between manual counting and platform A, 0.93 (p < 0.001) between manual counting and platform B, and 0.96 (p < 0.001) for inter-platform agreement. Scatterplots and Bland-Altman plots revealed no skewness within specific data ranges. In the few cases with ≥ 10% difference between manual counting and DIA, results by both platforms were similar. DIA using VDS is an accurate method to determine the Ki67 proliferation index in breast cancer, as an alternative to manual scoring of whole sections in clinical practice. Inter-platform agreement between two different DIA platforms was excellent, suggesting vendor-independent clinical implementability.

  14. Gait assessment using the Microsoft Xbox One Kinect: Concurrent validity and inter-day reliability of spatiotemporal and kinematic variables.

    PubMed

    Mentiplay, Benjamin F; Perraton, Luke G; Bower, Kelly J; Pua, Yong-Hao; McGaw, Rebekah; Heywood, Sophie; Clark, Ross A

    2015-07-16

    The revised Xbox One Kinect, also known as the Microsoft Kinect V2 for Windows, includes enhanced hardware which may improve its utility as a gait assessment tool. This study examined the concurrent validity and inter-day reliability of spatiotemporal and kinematic gait parameters estimated using the Kinect V2 automated body tracking system and a criterion reference three-dimensional motion analysis (3DMA) marker-based camera system. Thirty healthy adults performed two testing sessions consisting of comfortable and fast paced walking trials. Spatiotemporal outcome measures related to gait speed, speed variability, step length, width and time, foot swing velocity and medial-lateral and vertical pelvis displacement were examined. Kinematic outcome measures including ankle flexion, knee flexion and adduction and hip flexion were examined. To assess the agreement between Kinect and 3DMA systems, Bland-Altman plots, relative agreement (Pearson's correlation) and overall agreement (concordance correlation coefficients) were determined. Reliability was assessed using intraclass correlation coefficients, Cronbach's alpha and standard error of measurement. The spatiotemporal measurements had consistently excellent (r≥0.75) concurrent validity, with the exception of modest validity for medial-lateral pelvis sway (r=0.45-0.46) and fast paced gait speed variability (r=0.73). In contrast kinematic validity was consistently poor to modest, with all associations between the systems weak (r<0.50). In those measures with acceptable validity, the inter-day reliability was similar between systems. In conclusion, while the Kinect V2 body tracking may not accurately obtain lower body kinematic data, it shows great potential as a tool for measuring spatiotemporal aspects of gait. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Hypo- and hyperglycemia in relation to the mean, standard deviation, coefficient of variation, and nature of the glucose distribution.

    PubMed

    Rodbard, David

    2012-10-01

    We describe a new approach to estimate the risks of hypo- and hyperglycemia based on the mean and SD of the glucose distribution using optional transformations of the glucose scale to achieve a more nearly symmetrical and Gaussian distribution, if necessary. We examine the correlation of risks of hypo- and hyperglycemia calculated using different glucose thresholds and the relationships of these risks to the mean glucose, SD, and percentage coefficient of variation (%CV). Using representative continuous glucose monitoring datasets, one can predict the risk of glucose values above or below any arbitrary threshold if the glucose distribution is Gaussian or can be transformed to be Gaussian. Symmetry and gaussianness can be tested objectively and used to optimize the transformation. The method performs well with excellent correlation of predicted and observed risks of hypo- or hyperglycemia for individual subjects by time of day or for a specified range of dates. One can compare observed and calculated risks of hypo- and hyperglycemia for a series of thresholds considering their uncertainties. Thresholds such as 80 mg/dL can be used as surrogates for thresholds such as 50 mg/dL. We observe a high correlation of risk of hypoglycemia with %CV and illustrate the theoretical basis for that relationship. One can estimate the historical risks of hypo- and hyperglycemia by time of day, date, day of the week, or range of dates, using any specified thresholds. Risks of hypoglycemia with one threshold (e.g., 80 mg/dL) can be used as an effective surrogate marker for hypoglycemia at other thresholds (e.g., 50 mg/dL). These estimates of risk can be useful in research studies and in the clinical care of patients with diabetes.

  16. Development and psychometric evaluation of a clinical global impression for schizoaffective disorder scale.

    PubMed

    Allen, Michael H; Daniel, David G; Revicki, Dennis A; Canuso, Carla M; Turkoz, Ibrahim; Fu, Dong-Jing; Alphs, Larry; Ishak, K Jack; Bartko, John J; Lindenmayer, Jean-Pierre

    2012-01-01

    The Clinical Global Impression for Schizoaffective Disorder scale is a new rating scale adapted from the Clinical Global Impression scale for use in patients with schizoaffective disorder. The psychometric characteristics of the Clinical Global Impression for Schizoaffective Disorder are described. Content validity was assessed using an investigator questionnaire. Inter-rater reliability was determined with 12 sets of videotaped interviews rated independently by two trained individuals. Test-retest reliability was assessed using 30 randomly selected raters from clinical trials who evaluated the same videos on separate occasions two weeks apart. Convergent and divergent validity and effect size were evaluated by comparing scores between the Clinical Global Impression for Schizoaffective Disorder and the Positive and Negative Syndrome Scale, 21-item Hamilton Rating Scale for Depression, and Young Mania Rating Scale scales using pooled patient data from two clinical trials. Clinical Global Impression for Schizoaffective Disorder scores were then linked to corresponding Positive and Negative Syndrome Scale scores. Content validity was strong. Inter-rater agreement was good to excellent for most scales and subscales (intra-class correlation coefficient ≥ 0.50). Test-retest showed good reproducibility, with intraclass correlation coefficients ranging from 0.444 to 0.898. Spearman correlations between Clinical Global Impression for Schizoaffective Disorder domains and corresponding symptom scales were 0.60 or greater, and effect sizes for Clinical Global Impression for Schizoaffective Disorder overall and domain scores were similar to Positive and Negative Syndrome Scale Young Mania Rating Scale, and 21-item Hamilton Rating Scale for Depression scores. Raters anticipated that the scale might be less effective in distinguishing negative from depressive symptoms, and, in fact, the results here may reflect that clinical reality. Multiple lines of evidence support the reliability and validity of the Clinical Global Impression for Schizoaffective Disorder for studies in schizoaffective disorder.

  17. [Validity and reliability of Pediatric Quality of Life Inventory Version 4.0 Generic Core Scales in Chinese children and adolescents].

    PubMed

    Chen, Yu-Ming; He, Li-Ping; Mai, Jin-Cheng; Hao, Yuan-Tao; Xiong, Li-Hua; Chen, Wei-Qing; Wu, Jiang-Nan

    2008-06-01

    To evaluate the reliability and validity of parent proxy-report scales of Pediatric Quality of Life Inventory Version 4.0 (PedsQL 4.0) Generic Core Scales, the Chinese Version. 3493 school students aged 6-18 years were recruited using multistage cluster sampling method. Health-related quality of life was assessed using the above-mentioned PedsQL 4.0 scales. The internal consistency was assessed, using Cronbach's a coefficient, while its validity was tested through correlation analysis, t-test and exploratory factor analysis. The internal consistency reliability for Total Scale Score (Cronbach's alpha = 0.90), Physical Health Summary Score (alpha= 0.81), and Psychosocial Health Summary Score (alpha= 0.89) were excellent. Six major factors were extracted by factor analysis which basically matched the designed structure of the original version accounting for nearly 66% of the variance. The total Scale Score significantly decreased by 3.5 to 13.3 (P < 0.05) in children and adolescents who had diseases including cold, skin hypersensitiveness, food allergy, courbature or arthralgia, breathlessness with a frequency of 6 times or more per year or had asthma as compared to those with lower frequency (< or = 5 times/y) of the diseases or without asthma. We found moderate to high correlations between items and the subscales. Correlation coefficients ranged between 0.45 to 0.84 (P < 0.01). The reliability and validity of the parent proxy-report scales of PedsQL 4.0 Generic Core Scales of the Chinese Version were as good as the original version. Our findings suggested that the scales could be applied to evaluate the health-related quality of life in childhood children in similar Chinese regions to Guangzhou.

  18. Reproducibility of blood pressure responses to dietary sodium and potassium interventions: the GenSalt study.

    PubMed

    Gu, Dongfeng; Zhao, Qi; Chen, Jing; Chen, Ji-Chun; Huang, Jianfeng; Bazzano, Lydia A; Lu, Fanghong; Mu, Jianjun; Li, Jianxin; Cao, Jie; Mills, Katherine; Chen, Chung-Shiuan; Rice, Treva; Hamm, L Lee; He, Jiang

    2013-09-01

    Blood pressure responses to dietary sodium and potassium interventions vary among individuals. We studied the long-term reproducibility of blood pressure responses to dietary sodium and potassium intake. We repeated the dietary sodium and potassium interventions among 487 Chinese adults 4.5 years after the original dietary intervention. The identical dietary intervention protocol, which included a 7-day low-sodium feeding (51.3 mmol/d), a 7-day high-sodium feeding (307.8 mmol/d), and a 7-day high-sodium feeding with oral potassium supplementation (60.0 mmol/d), was applied in both the initial and repeated studies. Three blood pressure measurements were obtained during each of the 3 days of baseline observation and on days 5, 6, and 7 of each intervention period. The results from the 24-hour urinary excretion of sodium and potassium showed excellent compliance with the study diet. Blood pressure responses to dietary intervention in the original and repeated studies were highly correlated. For example, the correlation coefficients (95% confidence interval) for systolic blood pressure levels were 0.77 (0.73-0.80) at baseline, 0.79 (0.75-0.82) during low sodium, 0.80 (0.77-0.83) during high sodium, and 0.82 (0.79-0.85) during high sodium and potassium supplementation interventions (all P<0.0001). The correlation coefficients for systolic blood pressure changes were 0.37 (0.29-0.44) from baseline to low sodium, 0.37 (0.29-0.44) from low to high sodium, and 0.28 (0.20-0.36) from high sodium to high sodium plus potassium supplementation (all P<0.0001). These data indicate that blood pressure responses to dietary sodium and potassium interventions have long-term reproducibility and stable characteristics in the general population.

  19. The Cumberland Ankle Instability Tool (CAIT) in the Dutch population with and without complaints of ankle instability.

    PubMed

    Vuurberg, Gwendolyn; Kluit, Lana; van Dijk, C Niek

    2018-03-01

    To develop a translated Dutch version of the Cumberland Ankle Instability Tool (CAIT) and test its psychometric properties in a Dutch population with foot and ankle complaints. The CAIT was translated into the Dutch language using a forward-backward translation design. Of the 130 subsequent patients visiting the outpatient clinic for foot and ankle complaints who were asked to fill out a questionnaire containing the CAIT, the Foot and Ankle Outcome Score (FAOS), and the numeric rating scale (NRS) pain, 98 completed the questionnaire. After a 1-week period, patients were asked to fill out a second questionnaire online containing the CAIT and NRS pain. This second questionnaire was completed by 70 patients. With these data, the construct validity, test-retest reliability, internal consistency, measurement error, and ceiling and floor effects were assessed. Additionally, a cut-off value to discriminate between stable and unstable ankles, in patients with ankle complaints, was calculated. Construct validity showed moderate correlations between the CAIT and FAOS subscales (Spearman's correlation coefficient (SCC) = 0.36-0.43), and the NRS pain (SCC = -0.55). The cut-off value was found at 11.5 points of the total CAIT score (range 0-30). Test-retest reliability showed to be excellent with an intraclass correlation coefficient of 0.94. Internal consistency was high (Cronbach's α = 0.86). No ceiling or floor effects were detected. Based on the results, the Dutch version of the CAIT is a valid and reliable questionnaire to assess ankle instability in the Dutch population and is able to differentiate between a functionally unstable and stable ankle. The tool is the first suitable tool to objectify the severity of ankle instability specific complaints and assess change in the Dutch population. Level of evidence II.

  20. Handling of computational in vitro/in vivo correlation problems by Microsoft Excel: I. Principles and some general algorithms.

    PubMed

    Langenbucher, Frieder

    2002-01-01

    Most computations in the field of in vitro/in vivo correlations can be handled directly by Excel worksheets, without the need for specialized software. Following a summary of Excel features, applications are illustrated for numerical computation of AUC and Mean, Wagner-Nelson and Loo-Riegelman absorption plots, and polyexponential curve fitting.

  1. The development and reliability of a simple field based screening tool to assess core stability in athletes.

    PubMed

    O'Connor, S; McCaffrey, N; Whyte, E; Moran, K

    2016-07-01

    To adapt the trunk stability test to facilitate further sub-classification of higher levels of core stability in athletes for use as a screening tool. To establish the inter-tester and intra-tester reliability of this adapted core stability test. Reliability study. Collegiate athletic therapy facilities. Fifteen physically active male subjects (19.46 ± 0.63) free from any orthopaedic or neurological disorders were recruited from a convenience sample of collegiate students. The intraclass correlation coefficients (ICC) and 95% Confidence Intervals (CI) were computed to establish inter-tester and intra-tester reliability. Excellent ICC values were observed in the adapted core stability test for inter-tester reliability (0.97) and good to excellent intra-tester reliability (0.73-0.90). While the 95% CI were narrow for inter-tester reliability, Tester A and C 95% CI's were widely distributed compared to Tester B. The adapted core stability test developed in this study is a quick and simple field based test to administer that can further subdivide athletes with high levels of core stability. The test demonstrated high inter-tester and intra-tester reliability. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Reliability of Use, Abuse, and Dependence of Four Types of Inhalants in Adolescents and Young Adults

    PubMed Central

    Ridenour, Ty A.; Bray, Bethany C.; Cottler, Linda B.

    2007-01-01

    Inhalants, as a class of drugs, consists of heterogeneous substances that include some of the most dangerous drugs on a per use basis. Research on inhalant abuse has lagged behind other drugs partly because of the need for a diagnostic instrument of different types of inhalants. This study was conducted to obtain reliability estimates for the new Substance Abuse Module DSM-IV inhalants diagnoses for four types of inhalants: aerosols, gases, nitrites, and solvents as well as different diagnostic configurations of inhalant use. Participants were 162 community sample adolescents or young adults (mean age = 20.3 years, SD = 2.4). Two-thirds of the sample was male and 83.3% was Caucasian. Kappas and intraclass correlation coefficients were computed to estimate test-retest reliabilities. Results suggested (a) abuse was more common than dependence (34.6% vs. 12.3%), (b) reliabilities of abuse criteria and diagnosis were good to excellent across subtypes, and (c) reliabilities of dependence criteria and diagnoses were poor to good across subtypes. Alternative configurations of DSM-IV criteria that were consistent with previous research on adolescents provided excellent reliabilities across subtypes of inhalants. Moreover, 11.1% of participants experienced inhalants withdrawal. PMID:17576041

  3. Inter-rater reliability of Hamilton depression rating scale using video-recorded interviews — Focus on rater-blinding

    PubMed Central

    Prasad, M. Krishna; Udupa, K.; Kishore, K. R.; Thirthalli, J.; Sathyaprabha, T. N.; Gangadhar, B. N.

    2009-01-01

    Background: Hamilton depression rating scale (Ham-D) is the most widely used clinician rating scale for depression. There has been no Indian study that has examined the inter-rater reliability (IRR) of video-recorded interviews of the 21-item Ham-D. Aim: To study the IRR of scoring video-recorded interviews for 21-item Ham-D. Materials and Methods: Eighteen subjects with major depressive disorder involved in a larger study were interviewed using the semi-structured clinical interview of the 21-item Ham-D by a primary rater after informed consent. These interviews were video-recorded and portions edited to ensure rater blinding. Subsequently, the video-recorded interviews were rated by a “blind” rater. Both rated the different sub-domains of Ham-D according to Rhoades and Overall (1983). IRR was evaluated using intra-class correlation coefficient. Results: Excellent IRR was observed (0.9891) between the two raters. This was true for each of the primary factors and super-factors. Conclusion: Video recorded 21-item Ham-D has excellentIRR. Video-recorded interviews of Ham-D can be reliably used to blind raters in research. PMID:19881046

  4. Magnetic CuHCNPAN nano composite as an efficient adsorbent for strontium uptake

    NASA Astrophysics Data System (ADS)

    Mobtaker, Hossein Ghasemi; Pakzad, Seyed Mohammadreza; Yousefi, Taher

    2018-06-01

    An excellent composite was synthesized for sorption of strontium from solution. The composite (CuHCNPAN) components were copper hexacyanoferrate, magnetite and PAN. The XRD method confirmed the formation and presence of two crystalline phases of magnetite and copper hexacyanoferrate in composite. Particle sizes were determined by XRD and SEM methods. It was found that the particles were nano size. Some other methods such as FT IR, BET and TG methods were also used to determine the properties of the composite. The composite was used for sorption of strontium from solution. It was found that the kinetic of strontium sorption by the composite could be modeled by pseudo-second order. Among the isotherms applied to modeling the sorption in various concentrations, the Langmuir isotherm was founded to be more appropriate to fitting the experimental data. An excellent correlation coefficient was obtained (R2 > 0.98). The qmax for sorption of strontium ions which was calculated by Langmuir model was 80 mg/g. The thermodynamic parameters were calculated by determination of sorption in various temperatures and using the Vant Hoff plot. ΔG°, ΔH°, and ΔS° were calculated as -19.15, 2.28 and 0.071 kJ/mol respectively.

  5. Repeatability and reproducibility of measurements of the suburethral tape location obtained in pelvic floor ultrasound performed with a transvaginal probe

    PubMed Central

    Dresler, Maria Magdalena; Kociszewski, Jacek; Pędraszewski, Piotr; Trzeciak, Agnieszka; Surkont, Grzegorz

    2017-01-01

    Introduction Implants used to treat patients with urogynecological conditions are well visible in US examination. The position of the suburethral tape (sling) is determined in relation to the urethra or the pubic symphysis. Aim of the study The study was aimed at assessing the accuracy of measurements determining suburethral tape location obtained in pelvic US examination performed with a transvaginal probe. Material and methods The analysis covered the results of sonographic measurements obtained according to a standardized technique in women referred for urogynecological diagnostics. Data from a total of 68 patients were used to analyse the repeatability and reproducibility of results obtained on the same day. Results The intraclass correlation coefficient for the repeatability and reproducibility of the sonographic measurements of suburethral tape location obtained with a transvaginal probe ranged from 0.6665 to 0.9911. The analysis of the measurements confirmed their consistency to be excellent or good. Conclusions Excellent and good repeatability and reproducibility of the measurements of the suburethral tape location obtained in a pelvic ultrasound performed with a transvaginal probe confirm the test’s validity and usefulness for clinical and academic purposes. PMID:28856017

  6. DEVELOPMENT AND VALIDATION OF TWO FOOD FREQUENCY QUESTIONNAIRES TO ASSESS GLUTEN INTAKE IN CHILDREN UP TO 36 MONTHS OF AGE.

    PubMed

    Crespo Escobar, Paula; Calvo Lerma, Joaquim; Hervas Marin, David; Donat Aliaga, Ester; Masip Simó, Etna; Polo Miquel, Begoña; Ribes Koninckx, Carmen

    2015-11-01

    precise information on gluten consumption is crucial for specifically studying the impact of gluten introduction and gluten intake in celiac disease development. Our aim was to develop and validate tools (food frequency questionnaires, FFQs) for the assessment of gluten consumption in Spanish children aged 7-36 months. a total of 342 children, who attended primary healthcare centers for routine health surveys or La Fe Hospital for minor health problems as well as healthy children (recruited in nurseries and primary schools) participated in this survey. We have developed two different FFQs (one for 7-12 months and other for 13-36 months). For validation, results from two FFQs were compared with results of 2-day food records and also with the gold standard 7-day records. The mean gluten intake obtained by the 2DR vs. FFQ and the 7DR vs. FFQ, were compared using the Bland Altman plot method and also Lin's concordance correlation coefficient. we found a good agreement between our FFQs and the 2DR and 7DR according to the results of both the Bland-Altman plots and Lin's concordance correlation coefficient. our two new FFQs are therefore the only validated questionnaires available to determine gluten consumption in Spanish children. They are user-friendly and offer excellent instruments to assess gluten intake in children up to 36 months of age. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  7. External Validation of a Case-Mix Adjustment Model for the Standardized Reporting of 30-Day Stroke Mortality Rates in China

    PubMed Central

    Yu, Ping; Pan, Yuesong; Wang, Yongjun; Wang, Xianwei; Liu, Liping; Ji, Ruijun; Meng, Xia; Jing, Jing; Tong, Xu; Guo, Li; Wang, Yilong

    2016-01-01

    Background and Purpose A case-mix adjustment model has been developed and externally validated, demonstrating promise. However, the model has not been thoroughly tested among populations in China. In our study, we evaluated the performance of the model in Chinese patients with acute stroke. Methods The case-mix adjustment model A includes items on age, presence of atrial fibrillation on admission, National Institutes of Health Stroke Severity Scale (NIHSS) score on admission, and stroke type. Model B is similar to Model A but includes only the consciousness component of the NIHSS score. Both model A and B were evaluated to predict 30-day mortality rates in 13,948 patients with acute stroke from the China National Stroke Registry. The discrimination of the models was quantified by c-statistic. Calibration was assessed using Pearson’s correlation coefficient. Results The c-statistic of model A in our external validation cohort was 0.80 (95% confidence interval, 0.79–0.82), and the c-statistic of model B was 0.82 (95% confidence interval, 0.81–0.84). Excellent calibration was reported in the two models with Pearson’s correlation coefficient (0.892 for model A, p<0.001; 0.927 for model B, p = 0.008). Conclusions The case-mix adjustment model could be used to effectively predict 30-day mortality rates in Chinese patients with acute stroke. PMID:27846282

  8. Validity and Reliability of the Brazilian Version of the Rapid Estimate of Adult Literacy in Dentistry--BREALD-30.

    PubMed

    Junkes, Monica C; Fraiz, Fabian C; Sardenberg, Fernanda; Lee, Jessica Y; Paiva, Saul M; Ferreira, Fernanda M

    2015-01-01

    The aim of the present study was to translate, perform the cross-cultural adaptation of the Rapid Estimate of Adult Literacy in Dentistry to Brazilian-Portuguese language and test the reliability and validity of this version. After translation and cross-cultural adaptation, interviews were conducted with 258 parents/caregivers of children in treatment at the pediatric dentistry clinics and health units in Curitiba, Brazil. To test the instrument's validity, the scores of Brazilian Rapid Estimate of Adult Literacy in Dentistry (BREALD-30) were compared based on occupation, monthly household income, educational attainment, general literacy, use of dental services and three dental outcomes. The BREALD-30 demonstrated good internal reliability. Cronbach's alpha ranged from 0.88 to 0.89 when words were deleted individually. The analysis of test-retest reliability revealed excellent reproducibility (intraclass correlation coefficient = 0.983 and Kappa coefficient ranging from moderate to nearly perfect). In the bivariate analysis, BREALD-30 scores were significantly correlated with the level of general literacy (rs = 0.593) and income (rs = 0.327) and significantly associated with occupation, educational attainment, use of dental services, self-rated oral health and the respondent's perception regarding his/her child's oral health. However, only the association between the BREALD-30 score and the respondent's perception regarding his/her child's oral health remained significant in the multivariate analysis. The BREALD-30 demonstrated satisfactory psychometric properties and is therefore applicable to adults in Brazil.

  9. Validity and Reliability of the Brazilian Version of the Rapid Estimate of Adult Literacy in Dentistry – BREALD-30

    PubMed Central

    Junkes, Monica C.; Fraiz, Fabian C.; Sardenberg, Fernanda; Lee, Jessica Y.; Paiva, Saul M.; Ferreira, Fernanda M.

    2015-01-01

    Objective The aim of the present study was to translate, perform the cross-cultural adaptation of the Rapid Estimate of Adult Literacy in Dentistry to Brazilian-Portuguese language and test the reliability and validity of this version. Methods After translation and cross-cultural adaptation, interviews were conducted with 258 parents/caregivers of children in treatment at the pediatric dentistry clinics and health units in Curitiba, Brazil. To test the instrument's validity, the scores of Brazilian Rapid Estimate of Adult Literacy in Dentistry (BREALD-30) were compared based on occupation, monthly household income, educational attainment, general literacy, use of dental services and three dental outcomes. Results The BREALD-30 demonstrated good internal reliability. Cronbach’s alpha ranged from 0.88 to 0.89 when words were deleted individually. The analysis of test-retest reliability revealed excellent reproducibility (intraclass correlation coefficient = 0.983 and Kappa coefficient ranging from moderate to nearly perfect). In the bivariate analysis, BREALD-30 scores were significantly correlated with the level of general literacy (rs = 0.593) and income (rs = 0.327) and significantly associated with occupation, educational attainment, use of dental services, self-rated oral health and the respondent’s perception regarding his/her child's oral health. However, only the association between the BREALD-30 score and the respondent’s perception regarding his/her child's oral health remained significant in the multivariate analysis. Conclusion The BREALD-30 demonstrated satisfactory psychometric properties and is therefore applicable to adults in Brazil. PMID:26158724

  10. Magnetic Resonance Venous Volume Measurements in Peripheral Artery Disease (from ELIMIT).

    PubMed

    Kamran, Hassan; Nambi, Vijay; Negi, Smita; Yang, Eric Y; Chen, Changyi; Virani, Salim S; Kougias, Panos; Lumsden, Alan B; Morrisett, Joel D; Ballantyne, Christie M; Brunner, Gerd

    2016-11-01

    The relation between the arterial and venous systems in patients with impaired lower extremity blood flow remains poorly described. The objective of this secondary analysis of the Effectiveness of Intensive Lipid Modification Medication in Preventing the Progression on Peripheral Artery Disease Trial was to determine the association between femoral vein (FV) volumes and measurements of peripheral artery disease. FV wall, lumen, and total volumes were quantified with fast spin-echo proton density-weighted magnetic resonance imaging scans in 79 patients with peripheral artery disease over 2 years. Reproducibility was excellent for FV total vessel (intraclass correlation coefficient 0.924, confidence interval 0.910 to 0.935) and lumen volumes (intraclass correlation coefficient 0.893, confidence interval 0.873 to 0.910). Baseline superficial femoral artery volumes were directly associated with FV wall (r = 0.46, p <0.0001), lumen (r = 0.42, p = 0.0001), and total volumes (r = 0.46, p <0.0001). The 2-year change in maximum walking time was inversely associated with the 24-month change in FV total volume (r = -0.45, p = 0.03). In conclusion, FV volumes can be measured reliably with fast spin-echo proton density-weighted magnetic resonance imaging, and baseline superficial femoral artery plaque burden is positively associated with FV volumes, whereas the 2-year change in FV volumes and leg function show an inverse relation. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Construction of the Mandarin version of the International Prostate Symptom Score inventory in assessing lower urinary tract symptoms in a Malaysian population.

    PubMed

    Quek, Kia Fatt; Chua, Chong Beng; Razack, Azad Hassan; Low, Wah Yun; Loh, Chit Sin

    2005-01-01

    The purpose of the present study was to validate the Mandarin version of the International Prostate Symptom Score (Mand-IPSS) in a Malaysian population. The validity and reliability were studied in patients with lower urinary tract symptoms (LUTS; benign prostatic hyperplasia [BPH] group) and without LUTS (control group). Test-retest methodology was used to assess the reliability while Cronbach alpha was used to assess the internal consistency. Sensitivity to change was used to express the effect size index in the preintervention versus post-intervention score in patients with LUTS who underwent transurethral resection of the prostate. For the control group and BPH group, the internal consistency was excellent and a high degree of internal consistency was observed for all seven items (Cronbach alpha = 0.86-0.98 and 0.90-0.98, respectively). Test-retest correlation coefficients for all items were highly significant. Intraclass correlation coefficient (ICC) was high for the control (ICC = 0.93-0.99) and BPH group (ICC = 0.91-0.99). The sensitivity and specificity showed a high degree of sensitivity and specificity to the effects of treatment. A high degree of significance between baseline and post-treatment scores was observed across all seven items in the BPH group but not in the control group. The Mand-IPSS is a suitable, reliable, valid and sensitive instrument to measure clinical change in the Malaysian population.

  12. Cross-Cultural Adaptation, Validity, and Reliability of the Persian Version of the Orebro Musculoskeletal Pain Screening Questionnaire.

    PubMed

    Shafeei, Asrin; Mokhtarinia, Hamid Reza; Maleki-Ghahfarokhi, Azam; Piri, Leila

    2017-08-01

    Observational study. To cross-culturally translate the Orebro Musculoskeletal Pain Screening Questionnaire (OMPQ) into Persian and then evaluate its psychometric properties (reliability, validity, ceiling, and flooring effects). To the authors' knowledge, prior to this study there has been no validated instrument to screen the risk of chronicity in Persian-speaking patients with low back pain (LBP) in Iran. The OMPQ was specifically developed as a self-administered screening tool for assessing the risk of LBP chronicity. The forward-backward translation method was used for the translation and cross-cultural adaptation of the original questionnaire. In total, 202 patients with subacute LBP completed the OMPQ and the pain disability questionnaire (PDQ), which was used to assess convergent validity. 62 patients completed the OMPQ a week later as a retest. Slight changes were made to the OMPQ during the translation/cultural adaptation process; face validity of the Persian version was obtained. The Persian OMPQ showed excellent test-retest reliability (intraclass correlation coefficient=0.89). Its internal consistency was 0.71, and its convergent validity was confirmed by good correlation coefficient between the OMPQ and PDQ total scores ( r =0.72, p <0.05). No ceiling or floor effects were observed. The Persian version of the OMPQ is acceptable for the target society in terms of face validity, construct validity, reliability, and consistency. It is therefore considered a useful instrument for screening Iranian patients with LBP.

  13. Normal fetal posterior fossa in MR imaging: new biometric data and possible clinical significance.

    PubMed

    Ber, R; Bar-Yosef, O; Hoffmann, C; Shashar, D; Achiron, R; Katorza, E

    2015-04-01

    Posterior fossa malformations are a common finding in prenatal diagnosis. The objectives of this study are to re-evaluate existing normal MR imaging biometric data of the fetal posterior fossa, suggest and evaluate new parameters, and demonstrate the possible clinical applications of these data. This was a retrospective review of 215 fetal MR imaging examinations with normal findings and 5 examinations of fetuses with a suspected pathologic posterior fossa. Six previously reported parameters and 8 new parameters were measured. Three new parameter ratios were calculated. Interobserver agreement was calculated by using the intraclass correlation coefficient. For measuring each structure, 151-211 MR imaging examinations were selected, resulting in a normal biometry curve according to gestational age for each parameter. Analysis of the ratio parameters showed that vermian lobe ratio and cerebellar hemisphere ratio remain constant with gestational age and that the vermis-to-cisterna magna ratio varies with gestational age. Measurements of the 5 pathologic fetuses are presented on the normal curves. Interobserver agreement was excellent, with the intraclass correlation coefficients of most parameters above 0.9 and only 2 parameters below 0.8. The biometry curves derived from new and existing biometric data and presented in this study may expand and deepen the biometry we use today, while keeping it simple and repeatable. By applying these extensive biometric data on suspected abnormal cases, diagnoses may be confirmed, better classified, or completely altered. © 2015 by American Journal of Neuroradiology.

  14. Reliability and Validity of Athletes Disability Index Questionnaire.

    PubMed

    Noormohammadpour, Pardis; Hosseini Khezri, Alireza; Farahbakhsh, Farzin; Mansournia, Mohammad Ali; Smuck, Matthew; Kordi, Ramin

    2018-03-01

    The purpose of this study was to evaluate validity and reliability of a new proposed questionnaire for assessment of functional disability in athletes with low back pain (LBP). Validity and reliability study. Elite athletes participating in different fields of sports. Participants were 165 male and female athletes (between 12 and 50 years old) with LBP. Athlete Disability Index (ADI) Questionnaire which is developed by the authors for assessing LBP-related disability in athletes, Oswestry Disability Index (ODI), and the Roland-Morris Disability Questionnaire (RDQ). Self-reported responses were collected regarding LBP-related disability through ADI, ODI, and RDQ. The test-retest reliability was strong, and intraclass correlation value ranged between 0.74 and 0.94. The Cronbach alpha coefficient value of 0.91 (P < 0.001) demonstrated excellent internal consistency of the questionnaire. The correlation coefficient between ADI and ODI was r = 0.918 (P < 0.0001), between ADI and RDQ was r = 0.669 (P < 0.0001), and between ADI and visual analog scale was r = 0.626 (P < 0.001). According to ODI and RDQ, disability levels were mild in the large majority of subjects (91.5% and 86.0%, respectively). Alternatively, disability assessments by the ADI did not cluster at the mild level and ranged more broadly from mild to very high. The ADI is a reliable and valid instrument for assessing disability in athletes with LBP. Compared with the available LBP disability questionnaires used in the general population, ADI can more precisely stratify the disability levels of athletes due to LBP.

  15. Correlates of anxiety and depression among patients with type 2 diabetes mellitus.

    PubMed

    Balhara, Yatan Pal Singh; Sagar, Rajesh

    2011-07-01

    Research has established the relation between diabetes and depression. Both diabetes and anxiety/depression are independently associated with increased morbidity and mortality. The present study aims at assessing the prevalence of anxiety/depression among outpatients receiving treatment for type 2 diabetes. The study was conducted in the endocrinology outpatient department of an urban tertiary care center. The instruments used included a semi-structured questionnaire, HbA1c levels, fasting blood glucose and postprandial blood glucose, Brief Patient Health Questionnaire, and Hospital Anxiety and Depression Scale (HADS). Analysis was carried out using the SPSS version 16.0. Pearson's correlation coefficient was calculated to find out the correlations. ANOVA was carried out for the in between group comparisons. There was a significant correlation between the HADS-Anxiety scale and Body Mass Index (BMI) with a correlation coefficient of 0.34 (P = 0.008). Also, a significant correlation existed between HADS-Depression scale and BMI (correlation coefficient, 0.36; P = 0.004). Significant correlation were observed between the duration of daily physical exercise and HADS-Anxiety (coefficient of correlation, -0.25; P = 0.04) scores. HADS-Anxiety scores were found to be related to HbA1c levels (correlation-coefficient, 0.41; P = 0.03) and postprandial blood glucose levels (correlation-coefficient, 0.51; P = 0.02). Monitoring of biochemical parameters like HbA1c and postprandial blood glucose levels and BMI could be a guide to development of anxiety in these patients. Also, physical exercise seems to have a protective effect on anxiety in those with type 2 diabetes mellitus.

  16. Prediction of friction coefficients for gases

    NASA Technical Reports Server (NTRS)

    Taylor, M. F.

    1969-01-01

    Empirical relations are used for correlating laminar and turbulent friction coefficients for gases, with large variations in the physical properties, flowing through smooth tubes. These relations have been used to correlate friction coefficients for hydrogen, helium, nitrogen, carbon dioxide and air.

  17. QSPR modeling of octanol/water partition coefficient of antineoplastic agents by balance of correlations.

    PubMed

    Toropov, Andrey A; Toropova, Alla P; Raska, Ivan; Benfenati, Emilio

    2010-04-01

    Three different splits into the subtraining set (n = 22), the set of calibration (n = 21), and the test set (n = 12) of 55 antineoplastic agents have been examined. By the correlation balance of SMILES-based optimal descriptors quite satisfactory models for the octanol/water partition coefficient have been obtained on all three splits. The correlation balance is the optimization of a one-variable model with a target function that provides both the maximal values of the correlation coefficient for the subtraining and calibration set and the minimum of the difference between the above-mentioned correlation coefficients. Thus, the calibration set is a preliminary test set. Copyright (c) 2009 Elsevier Masson SAS. All rights reserved.

  18. Accuracy and reproducibility of novel echocardiographic three-dimensional automated software for the assessment of the aortic root in candidates for thanscatheter aortic valve replacement.

    PubMed

    García-Martín, Ana; Lázaro-Rivera, Carla; Fernández-Golfín, Covadonga; Salido-Tahoces, Luisa; Moya-Mur, Jose-Luis; Jiménez-Nacher, Jose-Julio; Casas-Rojo, Eduardo; Aquila, Iolanda; González-Gómez, Ariana; Hernández-Antolín, Rosana; Zamorano, José Luis

    2016-07-01

    A specialized three-dimensional transoesophageal echocardiography (3D-TOE) reconstruction tool has recently been introduced; the system automatically configures a geometric model of the aortic root from the images obtained by 3D-TOE and performs quantitative analysis of these structures. The aim of this study was to compare the measurements of the aortic annulus (AA) obtained by the new model to that obtained by 3D-TOE and multidetector computed tomography (MDCT) in candidates to transcatheter aortic valve implantation (TAVI) and to assess the reproducibility of this new method. We included 31 patients who underwent TAVI. The AA diameters and area were evaluated by the manual 3D-TOE method and by the automatic software. We showed an excellent correlation between the measurements obtained by both methods: intra-class correlation coefficient (ICC): 0.731 (0.508-0.862), r: 0.742 for AA diameter and ICC: 0.723 (0.662-0.923), r: 0.723 for the AA area, with no significant differences regardless of the method used. The interobserver variability was superior for the automatic measurements than for the manual ones. In a subgroup of 10 patients, we also found an excellent correlation between the automatic measurements and those obtained by MDCT, ICC: 0.941 (0.761-0.985), r: 0.901 for AA diameter and ICC: 0.853 (0.409-0.964), r: 0.744 for the AA area. The new automatic 3D-TOE software allows modelling and quantifying the aortic root from 3D-TOE data with high reproducibility. There is good correlation between the automated measurements and other 3D validated techniques. Our results support its use in clinical practice as an alternative to MDCT previous to TAVI. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  19. The Robustness of Designs for Trials with Nested Data against Incorrect Initial Intracluster Correlation Coefficient Estimates

    ERIC Educational Resources Information Center

    Korendijk, Elly J. H.; Moerbeek, Mirjam; Maas, Cora J. M.

    2010-01-01

    In the case of trials with nested data, the optimal allocation of units depends on the budget, the costs, and the intracluster correlation coefficient. In general, the intracluster correlation coefficient is unknown in advance and an initial guess has to be made based on published values or subject matter knowledge. This initial estimate is likely…

  20. Cardiac-gated, phase contrast magnetic resonance angiography is a reliable and reproducible technique for quantifying blood flow in canine major cranial abdominal vessels.

    PubMed

    Del Chicca, Francesca; Schwarz, Andrea; Grest, Paula; Willmitzer, Florian; Dennler, Matthias; Kircher, Patrick R

    2018-04-17

    Blood flow changes in cranial abdominal vessels are important contributing factors for canine hepatic disease. This prospective, experimental, pilot study aimed to evaluate cardiac-gated, phase contrast magnetic resonance angiography (PCMRA) as a method for characterizing blood flow in canine major cranial abdominal vessels. Eleven, healthy, adult beagle dogs were sampled. Cardiac-gated, phase contrast magnetic resonance angiography of the cranial abdomen was performed in each dog and blood flow was independently measured in each of the major cranial abdominal vessels by three observers, with two observers recording blood flow values once and one observer recording blood flow values three times. Each dog then underwent ultrasonographic examination of the liver with fine needle aspirations and biopsies submitted to cytologic and histologic examination. The mean absolute stroke volume and velocity were respectively 9.6 ± 1.9 ml and -11.1 ± 1.1 cm/s for the cranial abdominal aorta, 2.1 ± 0.6 ml and -6.6 ± 1.9 cm/s for the celiac artery, and 2.3 ± 1.0 ml and -7.9 ± 3.1 cm/s for the cranial mesenteric artery. The mean absolute stroke volume and velocity were respectively 6.7 ± 1.3 ml and 3.9 ± 0.9 cm/s for the caudal vena cava and 2.6 ± 0.9 ml and 3.2 ± 1.2 cm/s for the portal vein. Intraobserver reliability was excellent (intraclass correlation coefficient > 0.9). Interobserver reproducibility was also excellent (intraclass correlation coefficient 0.89-0.99). Results of liver ultrasonography, cytology, and histopathology were unremarkable. Findings indicated that cardiac-gated, phase contrast magnetic resonance angiography is a feasible technique for quantifying blood blow in canine major cranial abdominal vessels. Blood flow values from this sample of healthy beagles can be used as background for future studies on canine hepatic disease. © 2018 American College of Veterinary Radiology.

  1. Test-Retest Reliability of Graph Metrics in Functional Brain Networks: A Resting-State fNIRS Study

    PubMed Central

    Niu, Haijing; Li, Zhen; Liao, Xuhong; Wang, Jinhui; Zhao, Tengda; Shu, Ni; Zhao, Xiaohu; He, Yong

    2013-01-01

    Recent research has demonstrated the feasibility of combining functional near-infrared spectroscopy (fNIRS) and graph theory approaches to explore the topological attributes of human brain networks. However, the test-retest (TRT) reliability of the application of graph metrics to these networks remains to be elucidated. Here, we used resting-state fNIRS and a graph-theoretical approach to systematically address TRT reliability as it applies to various features of human brain networks, including functional connectivity, global network metrics and regional nodal centrality metrics. Eighteen subjects participated in two resting-state fNIRS scan sessions held ∼20 min apart. Functional brain networks were constructed for each subject by computing temporal correlations on three types of hemoglobin concentration information (HbO, HbR, and HbT). This was followed by a graph-theoretical analysis, and then an intraclass correlation coefficient (ICC) was further applied to quantify the TRT reliability of each network metric. We observed that a large proportion of resting-state functional connections (∼90%) exhibited good reliability (0.6< ICC <0.74). For global and nodal measures, reliability was generally threshold-sensitive and varied among both network metrics and hemoglobin concentration signals. Specifically, the majority of global metrics exhibited fair to excellent reliability, with notably higher ICC values for the clustering coefficient (HbO: 0.76; HbR: 0.78; HbT: 0.53) and global efficiency (HbO: 0.76; HbR: 0.70; HbT: 0.78). Similarly, both nodal degree and efficiency measures also showed fair to excellent reliability across nodes (degree: 0.52∼0.84; efficiency: 0.50∼0.84); reliability was concordant across HbO, HbR and HbT and was significantly higher than that of nodal betweenness (0.28∼0.68). Together, our results suggest that most graph-theoretical network metrics derived from fNIRS are TRT reliable and can be used effectively for brain network research. This study also provides important guidance on the choice of network metrics of interest for future applied research in developmental and clinical neuroscience. PMID:24039763

  2. In vitro performance of DIAGNOdent laser fluorescence device for dental calculus detection on human tooth root surfaces.

    PubMed

    Rams, Thomas E; Alwaqyan, Abdulaziz Y

    2017-10-01

    This study assessed the reproducibility of a red diode laser device, and its capability to detect dental calculus in vitro on human tooth root surfaces. On each of 50 extracted teeth, a calculus-positive and calculus-free root surface was evaluated by two independent examiners with a low-power indium gallium arsenide phosphide diode laser (DIAGNOdent) fitted with a periodontal probe-like sapphire tip and emitting visible red light at 655 nm wavelength. Laser autofluorescence intensity readings of examined root surfaces were scored on a 0-99 scale, with duplicate assessments performed using the laser probe tip directed both perpendicular and parallel to evaluated tooth root surfaces. Pearson correlation coefficients of untransformed measurements, and kappa analysis of data dichotomized with a >40 autofluorescence intensity threshold, were calculated to assess intra- and inter-examiner reproducibility of the laser device. Mean autofluorescence intensity scores of calculus-positive and calculus-free root surfaces were evaluated with the Student's t -test. Excellent intra- and inter-examiner reproducibility was found for DIAGNOdent laser autofluorescence intensity measurements, with Pearson correlation coefficients above 94%, and kappa values ranging between 0.96 and 1.0, for duplicate readings taken with both laser probe tip orientations. Significantly higher autofluorescence intensity values were measured when the laser probe tip was directed perpendicular, rather than parallel, to tooth root surfaces. However, calculus-positive roots, particularly with calculus in markedly-raised ledges, yielded significantly greater mean DIAGNOdent laser autofluorescence intensity scores than calculus-free surfaces, regardless of probe tip orientation. DIAGNOdent autofluorescence intensity values >40 exhibited a stronger association with calculus (36.6 odds ratio) then measurements of ≥5 (20.1 odds ratio) when the laser probe tip was advanced parallel to root surfaces. Excellent intra- and inter-examiner reproducibility of autofluorescence intensity measurements was obtained with the DIAGNOdent laser fluorescence device on human tooth roots. Calculus-positive root surfaces exhibited significantly greater DIAGNOdent laser autofluorescence than calculus-free tooth roots, even with the laser probe tip directed parallel to root surfaces. These findings provide further in vitro validation of the potential utility of a DIAGNOdent laser fluorescence device for identifying dental calculus on human tooth root surfaces.

  3. Reliability and accuracy of three imaging software packages used for 3D analysis of the upper airway on cone beam computed tomography images.

    PubMed

    Chen, Hui; van Eijnatten, Maureen; Wolff, Jan; de Lange, Jan; van der Stelt, Paul F; Lobbezoo, Frank; Aarab, Ghizlane

    2017-08-01

    The aim of this study was to assess the reliability and accuracy of three different imaging software packages for three-dimensional analysis of the upper airway using CBCT images. To assess the reliability of the software packages, 15 NewTom 5G ® (QR Systems, Verona, Italy) CBCT data sets were randomly and retrospectively selected. Two observers measured the volume, minimum cross-sectional area and the length of the upper airway using Amira ® (Visage Imaging Inc., Carlsbad, CA), 3Diagnosys ® (3diemme, Cantu, Italy) and OnDemand3D ® (CyberMed, Seoul, Republic of Korea) software packages. The intra- and inter-observer reliability of the upper airway measurements were determined using intraclass correlation coefficients and Bland & Altman agreement tests. To assess the accuracy of the software packages, one NewTom 5G ® CBCT data set was used to print a three-dimensional anthropomorphic phantom with known dimensions to be used as the "gold standard". This phantom was subsequently scanned using a NewTom 5G ® scanner. Based on the CBCT data set of the phantom, one observer measured the volume, minimum cross-sectional area, and length of the upper airway using Amira ® , 3Diagnosys ® , and OnDemand3D ® , and compared these measurements with the gold standard. The intra- and inter-observer reliability of the measurements of the upper airway using the different software packages were excellent (intraclass correlation coefficient ≥0.75). There was excellent agreement between all three software packages in volume, minimum cross-sectional area and length measurements. All software packages underestimated the upper airway volume by -8.8% to -12.3%, the minimum cross-sectional area by -6.2% to -14.6%, and the length by -1.6% to -2.9%. All three software packages offered reliable volume, minimum cross-sectional area and length measurements of the upper airway. The length measurements of the upper airway were the most accurate results in all software packages. All software packages underestimated the upper airway dimensions of the anthropomorphic phantom.

  4. Chinese Adaptation of the Bad Sobernheim Stress Questionnaire for Patients With Adolescent Idiopathic Scoliosis Under Brace Treatment.

    PubMed

    Xu, Ximing; Wang, Fei; Yang, Mingyuan; Huang, Qikai; Chang, Yifan; Wei, Xianzhao; Bai, Yushu; Li, Ming

    2015-08-01

    Bad Sobernheim Stress Questionnaire (BSSQ)-Deformity and BSSQ-Brace are the most widely used instruments for evaluating stress levels in adolescent idiopathic scoliosis (AIS) patients under brace treatment, and good reliability and validity have been demonstrated across different cultures. Great stress has been found among many adolescents, becoming a major concern for professionals. However, no previous research has addressed the cultural adaptations and psychometric testing of BSSQ-Deformity and BSSQ-Brace in China or the stress levels in AIS patients. The purposes of our study were to evaluate the cross-cultural adaptation and validation of the BSSQ-Deformity and BSSQ-Brace and to investigate stress levels in Chinese (AIS) patients under brace treatment.The original (German) versions of BSSQ-Deformity and BSSQ-Brace were cross-culturally translated according to international guidelines. Psychometric properties such as reliability and construct validity were tested. Eighty-six AIS patients were included in our study, and 50 patients paid a second visit 3 to 7 days later to test reproducibility. Cronbach α and the intraclass coefficient were determined to assess internal consistency and reproducibility. Scoliosis Research Society patient questionnaire-22 (SRS-22) was applied to evaluate construct validity.The mean BSSQ-Deformity and BSSQ-Brace scores were 15.3 and 13.4 points, respectively. Severe stress was observed in 12% of patients due to brace treatment. Item analysis demonstrated that each item was scored under a normal distribution with no redundancy. Psychometric analysis revealed excellent internal consistency (Cronbach α = 0.85 and 0.80, respectively) and reproducibility (intraclass correlation coefficient = 0.85 and 0.90, respectively) for BSSQ-Deformity and BSSQ-Brace. The correlation coefficients of BSSQ-Deformity, BSSQ-Brace and SRS-22 were 0.48 and 0.63, respectively.In conclusion, BSSQ-Deformity and BSSQ-Brace have been successfully adapted to a Chinese background and psychometrically validated with excellent reliability and construct validity. Brace wearing is considered the main cause of stress in AIS patients under brace treatment.

  5. Chinese Adaptation of the Bad Sobernheim Stress Questionnaire for Patients With Adolescent Idiopathic Scoliosis Under Brace Treatment

    PubMed Central

    Xu, Ximing; Wang, Fei; Yang, Mingyuan; Huang, Qikai; Chang, Yifan; Wei, Xianzhao; Bai, Yushu; Li, Ming

    2015-01-01

    Abstract Bad Sobernheim Stress Questionnaire (BSSQ)-Deformity and BSSQ-Brace are the most widely used instruments for evaluating stress levels in adolescent idiopathic scoliosis (AIS) patients under brace treatment, and good reliability and validity have been demonstrated across different cultures. Great stress has been found among many adolescents, becoming a major concern for professionals. However, no previous research has addressed the cultural adaptations and psychometric testing of BSSQ-Deformity and BSSQ-Brace in China or the stress levels in AIS patients. The purposes of our study were to evaluate the cross-cultural adaptation and validation of the BSSQ-Deformity and BSSQ-Brace and to investigate stress levels in Chinese (AIS) patients under brace treatment. The original (German) versions of BSSQ-Deformity and BSSQ-Brace were cross-culturally translated according to international guidelines. Psychometric properties such as reliability and construct validity were tested. Eighty-six AIS patients were included in our study, and 50 patients paid a second visit 3 to 7 days later to test reproducibility. Cronbach α and the intraclass coefficient were determined to assess internal consistency and reproducibility. Scoliosis Research Society patient questionnaire-22 (SRS-22) was applied to evaluate construct validity. The mean BSSQ-Deformity and BSSQ-Brace scores were 15.3 and 13.4 points, respectively. Severe stress was observed in 12% of patients due to brace treatment. Item analysis demonstrated that each item was scored under a normal distribution with no redundancy. Psychometric analysis revealed excellent internal consistency (Cronbach α = 0.85 and 0.80, respectively) and reproducibility (intraclass correlation coefficient = 0.85 and 0.90, respectively) for BSSQ-Deformity and BSSQ-Brace. The correlation coefficients of BSSQ-Deformity, BSSQ-Brace and SRS-22 were 0.48 and 0.63, respectively. In conclusion, BSSQ-Deformity and BSSQ-Brace have been successfully adapted to a Chinese background and psychometrically validated with excellent reliability and construct validity. Brace wearing is considered the main cause of stress in AIS patients under brace treatment. PMID:26252283

  6. Dynamics analysis of SIR epidemic model with correlation coefficients and clustering coefficient in networks.

    PubMed

    Zhang, Juping; Yang, Chan; Jin, Zhen; Li, Jia

    2018-07-14

    In this paper, the correlation coefficients between nodes in states are used as dynamic variables, and we construct SIR epidemic dynamic models with correlation coefficients by using the pair approximation method in static networks and dynamic networks, respectively. Considering the clustering coefficient of the network, we analytically investigate the existence and the local asymptotic stability of each equilibrium of these models and derive threshold values for the prevalence of diseases. Additionally, we obtain two equivalent epidemic thresholds in dynamic networks, which are compared with the results of the mean field equations. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. A novel coefficient for detecting and quantifying asymmetry of California electricity market based on asymmetric detrended cross-correlation analysis

    NASA Astrophysics Data System (ADS)

    Wang, Fang

    2016-06-01

    In order to detect and quantify asymmetry of two time series, a novel cross-correlation coefficient is proposed based on recent asymmetric detrended cross-correlation analysis (A-DXA), which we called A-DXA coefficient. The A-DXA coefficient, as an important extension of DXA coefficient ρ D X A , contains two directional asymmetric cross-correlated indexes, describing upwards and downwards asymmetric cross-correlations, respectively. By using the information of directional covariance function of two time series and directional variance function of each series itself instead of power-law between the covariance function and time scale, the proposed A-DXA coefficient can well detect asymmetry between the two series no matter whether the cross-correlation is significant or not. By means of the proposed A-DXA coefficient conducted over the asymmetry for California electricity market, we found that the asymmetry between the prices and loads is not significant for daily average data in 1999 yr market (before electricity crisis) but extremely significant for those in 2000 yr market (during the crisis). To further uncover the difference of asymmetry between the years 1999 and 2000, a modified H statistic (MH) and ΔMH statistic are proposed. One of the present contributions is that the high MH values calculated for hourly data exist in majority months in 2000 market. Another important conclusion is that the cross-correlation with downwards dominates over the whole 1999 yr in contrast to the cross-correlation with upwards dominates over the 2000 yr.

  8. Evaluation of the Correlation Coefficient of Polyethylene Glycol Treated and Direct Prolactin Results and Comparability with Different Assay System Results.

    PubMed

    Pal, Shyamali

    2017-12-01

    The presence of Macro prolactin is a significant cause of elevated prolactin resulting in misdiagnosis in all automated systems. Poly ethylene glycol (PEG) pretreatment is the preventive process but such process includes the probability of loss of a fraction of bioactive prolactin. Surprisingly, PEG treated EQAS & IQAS samples in Cobas e 411 are found out to be correlating with direct results of at least 3 immunoassay systems and treated and untreated Cobas e 411 results are comparable by a correlation coefficient. Comparison of EQAS, IQAS and patient samples were done to find out the trueness of such correlation factor. Study with patient's results have established the correlation coefficient is valid for very small concentration of prolactin also. EQAS, IQAS and 150 patient samples were treated with PEG and prolactin results of treated and untreated samples obtained from Roche Cobas e 411. 25 patient's results (treated) were compared with direct results in Advia Centaur, Architect I & Access2 systems. Correlation coefficient was obtained from trend line of the treated and untreated results. Two tailed p-value obtained from regression coefficient(r) and sample size. The correlation coefficient is in the range (0.761-0.771). Reverse correlation range is (1.289-1.301). r value of two sets of calculated results were 0.995. Two tailed p- value is zero approving dismissal of null hypothesis. The z-score of EQAS does not always assure authenticity of resultsPEG precipitation is correlated by the factor 0.761 even in very small concentrationsAbbreviationsGFCgel filtration chromatographyPEGpolyethylene glycolEQASexternal quality assurance systemM-PRLmacro prolactinPRLprolactinECLIAelectro-chemiluminescence immunoassayCLIAclinical laboratory improvement amendmentsIQASinternal quality assurance systemrregression coefficient.

  9. Bus electrode having same thermal expansion coefficient as crystalline silicon solar cell

    NASA Astrophysics Data System (ADS)

    Kato, T.; Morita, H.; Nakano, H.; Washida, H.; Onoe, A.; Inomata, K.; Mori, F.; Sugai, S.

    1982-01-01

    It is well known that the bus electrode plays a main role in series resistance of solar cells. Bus electrodes composed of bare leads, were investigated for which thermal expansion coefficients are less than those of the cell and which are coated with highly conducting metals. These leads exhibited the lower expansion coefficient than expected by empirical law, and the origins of these phenomena were explained. Work hardening effect on the expansion coefficient was then measured. Solar cell fabrication with these leads and rigid solders rationalized assembly processing. Cell characteristics proved to be excellent compared with conventional ones. Finally, lead costs were compared for various materials.

  10. Performance of the libraries in Isfahan University of Medical Sciences based on the EFQM model.

    PubMed

    Karimi, Saeid; Atashpour, Bahareh; Papi, Ahmad; Nouri, Rasul; Hasanzade, Akbar

    2014-01-01

    Performance measurement is inevitable for university libraries. Hence, planning and establishing a constant and up-to-date measurement system is required for the libraries, especially the university libraries. The primary studies and analyses reveal that the EFQM Excellence Model has been efficient, and the administrative reform program has focused on the implementation of this model. Therefore, on the basis of these facts as well as the need for a measurement system, the researchers measured the performance of libraries in schools and hospitals supported by Isfahan University of Medical Sciences, using the EFQM Organizational Excellence Model. This descriptive research study was carried out by a cross-sectional survey method in 2011. This research study included librarians and library directors of Isfahan University of Medical Sciences (70 people). The validity of the instrument was measured by the specialists in the field of Management and Library Science. To measure the reliability of the questionnaire, the Cronbach's alpha coefficient value was measured (0.93). The t-test, ANOVA, and Spearman's rank correlation coefficient were used for measurements. The data were analyzed by SPSS. Data analysis revealed that the mean score of the performance measurement for the libraries under study and between nine dimensions the highest score was 65.3% for leadership dimension and the lowest scores were 55.1% for people and 55.1% for society results. In general, using the ninth EFQM model the average level of all dimensions, which is in good agreement with normal values, was assessed. However, compared to other results, the criterion people and society results were poor. It is Recommended by forming the expert committee on criterion people and society results by individuals concerned with the various conferences and training courses to improve the aspects.

  11. Performance of the libraries in Isfahan University of Medical Sciences based on the EFQM model

    PubMed Central

    Karimi, Saeid; Atashpour, Bahareh; Papi, Ahmad; Nouri, Rasul; Hasanzade, Akbar

    2014-01-01

    Introduction: Performance measurement is inevitable for university libraries. Hence, planning and establishing a constant and up-to-date measurement system is required for the libraries, especially the university libraries. The primary studies and analyses reveal that the EFQM Excellence Model has been efficient, and the administrative reform program has focused on the implementation of this model. Therefore, on the basis of these facts as well as the need for a measurement system, the researchers measured the performance of libraries in schools and hospitals supported by Isfahan University of Medical Sciences, using the EFQM Organizational Excellence Model. Materials and Methods: This descriptive research study was carried out by a cross-sectional survey method in 2011. This research study included librarians and library directors of Isfahan University of Medical Sciences (70 people). The validity of the instrument was measured by the specialists in the field of Management and Library Science. To measure the reliability of the questionnaire, the Cronbach's alpha coefficient value was measured (0.93). The t-test, ANOVA, and Spearman's rank correlation coefficient were used for measurements. The data were analyzed by SPSS. Results: Data analysis revealed that the mean score of the performance measurement for the libraries under study and between nine dimensions the highest score was 65.3% for leadership dimension and the lowest scores were 55.1% for people and 55.1% for society results. Conclusion: In general, using the ninth EFQM model the average level of all dimensions, which is in good agreement with normal values, was assessed. However, compared to other results, the criterion people and society results were poor. It is Recommended by forming the expert committee on criterion people and society results by individuals concerned with the various conferences and training courses to improve the aspects. PMID:25540795

  12. Tuning the electronic hybridization in the heavy fermion cage compound YbFe2Zn20 with Cd doping

    NASA Astrophysics Data System (ADS)

    Cabrera-Baez, M.; Ribeiro, R. A.; Avila, M. A.

    2016-09-01

    The tuning of the electronic properties of heavy fermion compounds by chemical substitution provides excellent opportunities for further understanding the physics of hybridized ions in crystal lattices. Here we present an investigation on the effects of Cd doping in flux-grown single crystals of the complex intermetallic cage compound YbFe2Zn20, which has been described as a heavy fermion with a Sommerfeld coefficient of 535 mJ mol-1 · K-2. The substitution of Cd for Zn disturbs the system by expanding the unit cell and, in this case, the size of the Zn cages that surround the Yb and Fe. With an increasing amount of Cd, the hybridization between the Yb 4f electrons and the conduction electrons is weakened, as shown by a decrease in the Sommerfeld coefficient, which should be accompanied by a valence shift of the Yb3+ due to the negative chemical pressure effect. This scenario is also supported by the low temperature DC magnetic susceptibility, which is gradually suppressed and shows an increment of the Kondo temperature, based on a shift to higher temperatures of the characteristic broad susceptibility peak. Furthermore, the DC resistivity decreases with the isoelectronic substitution of Cd for Zn, contrary to expectations in an increasingly disordered system, and implying that the valence shift is not related to charge carrier doping. The combined results demonstrate the excellent complementarity between positive physical pressure and negative chemical pressure, and point to a rich playground for exploring the physics and chemistry of strongly correlated electron systems in the general family of Zn20 compounds, despite their structural complexity.

  13. Validation of the Compassion Fatigue Short Scale among Chinese medical workers and firefighters: a cross-sectional study

    PubMed Central

    Sun, Binghai; Hu, Mengna; Yu, Shitian; Jiang, Yiru; Lou, Baona

    2016-01-01

    Objectives To examine the psychometric properties of the Chinese version of the C-Compassion Fatigue (CF)-Short Scale among 4 independent samples of Chinese emergency workers (medical workers and firefighters). Design Cross-sectional. Setting 6 hospitals in Zhejiang Province and 12 fire stations in Shanghai. Participants Emergency workers (medical and firefighters) were consecutively recruited and divided into 4 groups: the MW1 group (medical workers, n=167), the FF1 group (firefighters, n=157), the MW2 group (medical workers, n=265) and the FF2 group (firefighters, n=231). Interventions All patients completed the C-CF-Short Scale to identify factors associated with compassion fatigue. The MW1 and FF1 groups were used for the exploratory analyses. The MW2 and FF2 groups were used for the confirmatory factor analyses. Primary and secondary outcome measures Factor loading, correlations with previously validated questionnaires (the Ego-Resiliency Scale, the Social Support Questionnaire and the Job Pressure Scale) and Cronbach's α coefficient were tested for each factor. Results The C-CF-Short Scale demonstrated excellent construct validity and good internal consistency. Specifically, the results of exploratory factor analyses in the MW1 and FF1 groups showed that secondary trauma and job burnout were associated with compassion fatigue in these emergency workers. The confirmatory factor analyses in the MW2 and FF2 groups indicated that all the fit indices of the 2-factor model were satisfactory. Finally, the Cronbach's α coefficient of each factor was excellent. Conclusions The findings suggest that the C-CF-Short Scale has good psychometric properties and can be applied to study Chinese emergency workers. PMID:27363817

  14. Validity and reliability of Optojump photoelectric cells for estimating vertical jump height.

    PubMed

    Glatthorn, Julia F; Gouge, Sylvain; Nussbaumer, Silvio; Stauffacher, Simone; Impellizzeri, Franco M; Maffiuletti, Nicola A

    2011-02-01

    Vertical jump is one of the most prevalent acts performed in several sport activities. It is therefore important to ensure that the measurements of vertical jump height made as a part of research or athlete support work have adequate validity and reliability. The aim of this study was to evaluate concurrent validity and reliability of the Optojump photocell system (Microgate, Bolzano, Italy) with force plate measurements for estimating vertical jump height. Twenty subjects were asked to perform maximal squat jumps and countermovement jumps, and flight time-derived jump heights obtained by the force plate were compared with those provided by Optojump, to examine its concurrent (criterion-related) validity (study 1). Twenty other subjects completed the same jump series on 2 different occasions (separated by 1 week), and jump heights of session 1 were compared with session 2, to investigate test-retest reliability of the Optojump system (study 2). Intraclass correlation coefficients (ICCs) for validity were very high (0.997-0.998), even if a systematic difference was consistently observed between force plate and Optojump (-1.06 cm; p < 0.001). Test-retest reliability of the Optojump system was excellent, with ICCs ranging from 0.982 to 0.989, low coefficients of variation (2.7%), and low random errors (±2.81 cm). The Optojump photocell system demonstrated strong concurrent validity and excellent test-retest reliability for the estimation of vertical jump height. We propose the following equation that allows force plate and Optojump results to be used interchangeably: force plate jump height (cm) = 1.02 × Optojump jump height + 0.29. In conclusion, the use of Optojump photoelectric cells is legitimate for field-based assessments of vertical jump height.

  15. Validity and test–retest reliability of a novel simple back extensor muscle strength test

    PubMed Central

    Harding, Amy T; Weeks, Benjamin Kurt; Horan, Sean A; Little, Andrew; Watson, Steven L; Beck, Belinda Ruth

    2017-01-01

    Objectives: To develop and determine convergent validity and reliability of a simple and inexpensive clinical test to quantify back extensor muscle strength. Methods: Two testing sessions were conducted, 7 days apart. Each session involved three trials of standing maximal isometric back extensor muscle strength using both the novel test and isokinetic dynamometry. Lumbar spine bone mineral density was examined by dual-energy X-ray absorptiometry. Validation was examined with Pearson correlations (r). Test–retest reliability was examined with intraclass correlation coefficients and limits of agreement. Pearson correlations and intraclass correlation coefficients are presented with corresponding 95% confidence intervals. Linear regression was used to examine the ability of peak back extensor muscle strength to predict indices of lumbar spine bone mineral density and strength. Results: A total of 52 healthy adults (26 men, 26 women) aged 46.4 ± 20.4 years were recruited from the community. A strong positive relationship was observed between peak back extensor strength from hand-held and isokinetic dynamometry (r = 0.824, p < 0.001). For the novel back extensor strength test, short- and long-term reliability was excellent (intraclass correlation coefficient = 0.983 (95% confidence interval, 0.971–0.990), p < 0.001 and intraclass correlation coefficient = 0.901 (95% confidence interval, 0.833–0.943), p < 0.001, respectively). Limits of agreement for short-term repeated back extensor strength measures with the novel back extensor strength protocol were −6.63 to 7.70 kg, with a mean bias of +0.71 kg. Back extensor strength predicted 11% of variance in lumbar spine bone mineral density (p < 0.05) and 9% of lumbar spine index of bone structural strength (p < 0.05). Conclusion: Our novel hand-held dynamometer method to determine back extensor muscle strength is quick, relatively inexpensive, and reliable; demonstrates initial convergent validity in a healthy population; and is associated with bone mass at a clinically important site. PMID:28255442

  16. Interrater reliability among epilepsy centers: multicenter study of epilepsy surgery.

    PubMed

    Haut, Sheryl R; Berg, Anne T; Shinnar, Shlomo; Cohen, Hillel W; Bazil, Carl W; Sperling, Michael R; Langfitt, John T; Pacia, Steven V; Walczak, Thaddeus S; Spencer, Susan S

    2002-11-01

    To measure the interrater reliability of presurgical testing and surgical decisions among epilepsy centers. Seven centers participating in an ongoing, prospective multicenter study of resective epilepsy surgery agreed to conform to a detailed protocol regarding presurgical evaluation and surgery. To assess quality assurance, each center independently reviewed 21 randomly selected surgical cases for preoperative study lateralization and localization, and surgical decisions. Interrater reliability was assessed by using intraclass correlation coefficients (ICCs), validated for use with multiple raters, and calculated in a two-way random model based on absolute agreement. Agreement for ICC values: > or = 0.75, excellent; 0.60-0.74, good; 0.40-0.59, fair; < or = 0.39, poor. One center was excluded for missing data. Agreement was excellent for extracranial EEG lateralization (0.8039), magnetic resonance imaging (MRI) lateralization (0.9521) and localization (0.9130), Wada lateralization (0.9453), and intracranial EEG localization (0.7905). Agreement was good for extracranial EEG localization (0.7384) and neuropsychological testing lateralization (0.7178) and localization (0.6891). Consensus about the decision to perform intracranial monitoring was fair (0.5397), in part reflecting one center's tendency toward intracranial monitoring. Overall agreements on whether to perform surgery (0.8311) and specific surgery recommended (0.8164) were excellent. High interrater reliability among six epilepsy centers was present for interpretation of most components of presurgical testing. Although consensus for the decision to perform intracranial monitoring was only fair, agreements for the ultimate decision about resective surgery and specific choice of resection were excellent. We believe that this study demonstrates the feasibility of implementing multicenter protocols for neurologic management, especially those involving localization, as well as protocols combining study results with clinical decision making.

  17. Anthropometry of Women of the U.S. Army--1977. Report Number 4. Correlation Coefficients

    DTIC Science & Technology

    1980-02-01

    S.... •, 0 76 x:. ADo5 //64 ! TECHNICAL REPORT NATICK/TR-80/016 (/ II ANTHROPOMETRY OF WOMEN OF THE U.S. ARMY-1977 Report No. 4 Correlation...NUMBER NATICK/TR-80/016 4. TITLE (and Subtitle) 5. TYPE OF REPORT & PERIOD COVERED ANTHROPOMETRY OF WOMEN OF THE U.S. ARMY--1977 Technical Report REPORT NO... Anthropometry Survey(s) Coefficients of correlation Measurement(s) U.S. Army Correlation coefficients Body size Military personnel Equation(s) Sizes

  18. Reliability of the Swedish version of the Exercise Self-Efficacy Scale (S-ESES): a test-retest study in adults with neurological disease.

    PubMed

    Ahlström, Isabell; Hellström, Karin; Emtner, Margareta; Anens, Elisabeth

    2015-03-01

    To examine the test-retest reliability of the Swedish translated version of the Exercise Self-Efficacy Scale (S-ESES) in people with neurological disease and to examine internal consistency. Test-retest study. A total of 30 adults with neurological diseases including: Parkinson's disease; Multiple Sclerosis; Cervical Dystonia; and Charcot-Marie-Tooth disease. The S-ESES was sent twice by surface mail. Completion interval mean was 16 days apart. Weighted kappa, intraclass correlation coefficient 2,1 [ICC (2,1)], standard error of measurement (SEM), also expressed as a percentage value (SEM%), and Cronbach's alpha were calculated. The relative reliability of the test-retest results showed substantial agreement measured using weighted kappa (MD = 0.62) and a very high-reliability ICC (2,1) (0.92). Absolute reliability measured using SEM was 5.3 and SEM% was 20.7. Excellent internal consistency was shown, with an alpha coefficient of 0.91 (test 1) and 0.93 (test 2). The S-ESES is recommended for use in research and in clinical work for people with neurological diseases. The low-absolute reliability, however, indicates a limited ability to measure changes on an individual level.

  19. Estimation of Temporal Gait Parameters Using a Human Body Electrostatic Sensing-Based Method.

    PubMed

    Li, Mengxuan; Li, Pengfei; Tian, Shanshan; Tang, Kai; Chen, Xi

    2018-05-28

    Accurate estimation of gait parameters is essential for obtaining quantitative information on motor deficits in Parkinson's disease and other neurodegenerative diseases, which helps determine disease progression and therapeutic interventions. Due to the demand for high accuracy, unobtrusive measurement methods such as optical motion capture systems, foot pressure plates, and other systems have been commonly used in clinical environments. However, the high cost of existing lab-based methods greatly hinders their wider usage, especially in developing countries. In this study, we present a low-cost, noncontact, and an accurate temporal gait parameters estimation method by sensing and analyzing the electrostatic field generated from human foot stepping. The proposed method achieved an average 97% accuracy on gait phase detection and was further validated by comparison to the foot pressure system in 10 healthy subjects. Two results were compared using the Pearson coefficient r and obtained an excellent consistency ( r = 0.99, p < 0.05). The repeatability of the purposed method was calculated between days by intraclass correlation coefficients (ICC), and showed good test-retest reliability (ICC = 0.87, p < 0.01). The proposed method could be an affordable and accurate tool to measure temporal gait parameters in hospital laboratories and in patients' home environments.

  20. Reliability of an analysis method for measuring diaphragm excursion by means of direct visualization with videofluoroscopy.

    PubMed

    Yi, Liu C; Nascimento, Oliver A; Jardim, José R

    2011-06-01

    The purpose of this study was to verify the reproducibility between two different observers of an analysis method for diaphragmatic displacement measurements using direct visualization with videofluoroscopy. 29 mouth breathing children aged 5 to 12 years from both genders were analyzed. The diaphragmatic displacement evaluation was divided in three parts: videofluoroscopy with VHS recording in standing, sitting, and dorsal positions; digitalization of the images; and measurement of the distance between diaphragmatic domes during a breathing cycle using Adobe Photoshop 5.5 and Adobe Premiere PRO 6.5 software. The intraclass correlation coefficients presented excellent reproducibility in all positions, with coefficients always above 0.94. Mean of the measurements of the diaphagramatic domes displacement done by the two observers were similar (P<.05), with the exception of right diaphragmatic displacement in the seated position and left diaphragmatic displacement in the standing position (P<.05). This study demonstrated that the evaluation of diaphragmatic displacement via videofluoroscopy is a reproducible measurement when two trained investigators are compared. This fact indicates that the present technique can be disseminated and performed by other healthcare professionals. Copyright © 2010 SEPAR. Published by Elsevier Espana. All rights reserved.

  1. Nerve ultrasound reliability of upper limbs: Effects of examiner training.

    PubMed

    Garcia-Santibanez, Rocio; Dietz, Alexander R; Bucelli, Robert C; Zaidman, Craig M

    2018-02-01

    Duration of training to reliably measure nerve cross-sectional area with ultrasound is unknown. A retrospective review was performed of ultrasound data, acquired and recorded by 2 examiners-an expert and either a trainee with 2 months (novice) or a trainee with 12 months (experienced) of experience. Data on median, ulnar, and radial nerves were reviewed for 42 patients. Interrater reliability was good and varied most with nerve site but little with experience. Coefficient of variation (CoV) range was 9.33%-22.5%. Intraclass correlation coefficient (ICC) was good to excellent (0.65-95) except ulnar nerve-wrist/forearm and radial nerve-humerus (ICC = 0.39-0.59). Interrater differences did not vary with nerve size or body mass index. Expert-novice and expert-experienced interrater differences and CoV were similar. The ulnar nerve-wrist expert-novice interrater difference decreased with time (r s  = -0.68, P = 0.001). A trainee with at least 2 months of experience can reliably measure upper limb nerves. Reliability varies by nerve and location and slightly improves with time. Muscle Nerve 57: 189-192, 2018. © 2017 Wiley Periodicals, Inc.

  2. DCCA cross-correlation coefficients reveals the change of both synchronization and oscillation in EEG of Alzheimer disease patients

    NASA Astrophysics Data System (ADS)

    Chen, Yingyuan; Cai, Lihui; Wang, Ruofan; Song, Zhenxi; Deng, Bin; Wang, Jiang; Yu, Haitao

    2018-01-01

    Alzheimer's disease (AD) is a degenerative disorder of neural system that affects mainly the older population. Recently, many researches show that the EEG of AD patients can be characterized by EEG slowing, enhanced complexity of the EEG signals, and EEG synchrony. In order to examine the neural synchrony at multi scales, and to find a biomarker that help detecting AD in diagnosis, detrended cross-correlation analysis (DCCA) of EEG signals is applied in this paper. Several parameters, namely DCCA coefficients in the whole brain, DCCA coefficients at a specific scale, maximum DCCA coefficient over the span of all time scales and the corresponding scale of such coefficients, were extracted to examine the synchronization, respectively. The results show that DCCA coefficients have a trend of increase as scale increases, and decreases as electrode distance increases. Comparing DCCA coefficients in AD patients with healthy controls, a decrease of synchronization in the whole brain, and a bigger scale corresponding to maximum correlation is discovered in AD patients. The change of max-correlation scale may relate to the slowing of oscillatory activities. Linear combination of max DCCA coefficient and max-correlation scale reaches a classification accuracy of 90%. From the above results, it is reasonable to conclude that DCCA coefficient reveals the change of both oscillation and synchrony in AD, and thus is a powerful tool to differentiate AD patients from healthy elderly individuals.

  3. Validation of a contemporary adherence measure for children with Type 1 diabetes: the Diabetes Management Questionnaire

    PubMed Central

    Mehta, S. N.; Nansel, T. R.; Volkening, L. K.; Butler, D. A.; Haynie, D. L.; Laffel, L. M. B.

    2016-01-01

    Aims To evaluate the psychometric properties of the Diabetes Management Questionnaire, a brief, self-report measure of adherence to contemporary diabetes management for young people with Type 1 diabetes and their caregivers. Methods A total of 273 parent-child dyads completed parallel versions of the Diabetes Management Questionnaire. Eligible children (aged 8–18 years) had Type 1 diabetes for ≥1 year. A multidisciplinary team designed the Diabetes Management Questionnaire as a brief, self-administered measure of adherence to Type 1 diabetes management over the preceding month; higher scores reflect greater adherence. Psychometrics were evaluated for the entire sample and according to age of the child. Results The children (49% female) had a mean ± SD (range) age 13.3 ± 2.9 (8–18) years and their mean ± SD HbA1c was 71 ± 15 mmol/mol (8.6 ± 1.4%). Internal consistency was good for parents (α = 0.83) and children (a = 0.79). Test-retest reliability was excellent for parents (intraclass correlation coefficient =0.83) and good for children (intraclass correlation coefficient = 0.65). Parent and child scores had moderate agreement (intraclass correlation coefficient = 0.54). Diabetes Management Questionnaire scores were inversely associated with HbA1c (parents: r = –0.41, P < 0.0001; children: r = –0.27, P < 0.0001). Psychometrics were stronger in the children aged ≥13 years compared with those aged < 13 years, but were acceptable in both age groups. Mean ± SD Diabetes Management Questionnaire scores were higher among children who were receiving insulin pump therapy (n = 181) than in children receiving multiple daily injections (n = 92) according to parent (75.9 ± 11.8 vs. 70.5 ± 15.5; P = 0.004) and child report (72.2 ± 12.1 vs. 67.6 ± 13.9; P = 0.006). Conclusions The Diabetes Management Questionnaire is a brief, valid self-report measure of adherence to contemporary diabetes self-management for people aged 8–18 years who are receiving either multiple daily injections or insulin pump therapy. PMID:26280463

  4. Web-Based Assessment of Mental Well-Being in Early Adolescence: A Reliability Study.

    PubMed

    Hamann, Christoph; Schultze-Lutter, Frauke; Tarokh, Leila

    2016-06-15

    The ever-increasing use of the Internet among adolescents represents an emerging opportunity for researchers to gain access to larger samples, which can be queried over several years longitudinally. Among adolescents, young adolescents (ages 11 to 13 years) are of particular interest to clinicians as this is a transitional stage, during which depressive and anxiety symptoms often emerge. However, it remains unclear whether these youngest adolescents can accurately answer questions about their mental well-being using a Web-based platform. The aim of the study was to examine the accuracy of responses obtained from Web-based questionnaires by comparing Web-based with paper-and-pencil versions of depression and anxiety questionnaires. The primary outcome was the score on the depression and anxiety questionnaires under two conditions: (1) paper-and-pencil and (2) Web-based versions. Twenty-eight adolescents (aged 11-13 years, mean age 12.78 years and SD 0.78; 18 females, 64%) were randomly assigned to complete either the paper-and-pencil or the Web-based questionnaire first. Intraclass correlation coefficients (ICCs) were calculated to measure intrarater reliability. Intraclass correlation coefficients were calculated separately for depression (Children's Depression Inventory, CDI) and anxiety (Spence Children's Anxiety Scale, SCAS) questionnaires. On average, it took participants 17 minutes (SD 6) to answer 116 questions online. Intraclass correlation coefficient analysis revealed high intrarater reliability when comparing Web-based with paper-and-pencil responses for both CDI (ICC=.88; P<.001) and the SCAS (ICC=.95; P<.001). According to published criteria, both of these values are in the "almost perfect" category indicating the highest degree of reliability. The results of the study show an excellent reliability of Web-based assessment in 11- to 13-year-old children as compared with the standard paper-pencil assessment. Furthermore, we found that Web-based assessments with young adolescents are highly feasible, with all enrolled participants completing the Web-based form. As early adolescence is a time of remarkable social and behavioral changes, these findings open up new avenues for researchers from diverse fields who are interested in studying large samples of young adolescents over time.

  5. Is distal femoral torsion the same in both of a patient's legs? Morphometric CT study.

    PubMed

    Beranger, J-S; Dujardin, D; Taburet, J-F; Boisrenoult, P; Steltzlen, C; Beaufils, P; Pujol, N

    2018-04-18

    The rotational position of the femoral component is a primary driver of success in total knee arthroplasty. However, distal femoral torsion (DFT) varies greatly between individuals. Measuring DFT preoperatively by CT in combination with computer-assisted surgery can significantly improve the rotational positioning of the femoral component. However, a preoperative CT scan is costly and exposes the patient to radiation. These are doubled when the patient is undergoing bilateral arthroplasty. The aim of this study was to determine the DFT in both knees of a patient undergoing bilateral arthroplasty. We hypothesized that DFT was symmetric between a patient's two knees and was independent of frontal alignment. In this retrospective study of TKA cases performed between December 2008 and March 2015, 82 patients (mean age 73years) who underwent two-stage bilateral TKA (164 knees) were included. A preoperative CT scan of each knee was performed to measure the DFT using the surgical posterior condylar angle (PCA) described by Yoshioka. Two observers performed the measurements twice each, to allow calculation of the intraclass and interclass correlation coefficients. The mean PCA was 5.4° (±1.48) in the right knee and 5.4° (±1.45) in the left knee, with a left/right difference ranging from 0 to 2.2° (p=0.8). In the entire cohort, 84.6% of patients had a left/right difference of less than 1°. We found no significant differences in DFT in knees with large or small frontal deformity (deformity<10°, p=0.7; deformity>10°, p=0.5) or the presence of varus or valgus (p=0.9). The intraclass correlation coefficient was excellent (94%) and the interclass correlation coefficient was moderate to good (60% for left knees, 53% for right knees). Based on CT scan measurements, the DFT in both knees of an arthritic patient is comparable and this measurement is reproducible. This means that a single, unilateral preoperative CT scan is sufficient for planning purposes. IV (retrospective cohort study). Copyright © 2018. Published by Elsevier Masson SAS.

  6. Cross-cultural adaptation and validation of the Arabic version of the Physical Activity Scale for the Elderly among community-dwelling older adults in Saudi Arabia.

    PubMed

    Alqarni, Ayidh M; Vennu, Vishal; Alshammari, Sulaiman A; Bindawas, Saad M

    2018-01-01

    Older adults are the fastest growing population group worldwide. Regular physical activity (PA) is reported to reduce the risk of health conditions and improve personal well-being. Few validated instruments can be used to measure the PA levels among older adults in Saudi Arabia. The Physical Activity Scale for the Elderly (PASE) is used worldwide for evaluating the PA levels of the elderly in epidemiological studies. However, this scale has not been translated into Arabic. This study aimed to cross-culturally adapt the PASE into Arabic language and evaluate its reliability and validity among community-dwelling older adults in Saudi Arabia. This study was a cross-sectional one following Beaton guidelines to translate and perform cultural adaptation, as well as test the reliability and validity of the PASE Arabic version (PASE-A). Elderly (N=74) people from both genders, who lived in a community dwelling in Riyadh city, were selected from several primary health care centers. The study used Cronbach's alpha coefficient to assess the internal consistency reliability, while intraclass correlation coefficient (ICC 2,1 ) was used for test-retest reliability and the Spearman's rank correlation coefficient ( r ) was used to evaluate the correlation among PASE-A and grip strength, Timed Up and Go test, body mass index, and fat percentage. Out of 74 older adults, 59 (79.7%) completed the PASE-A questionnaire twice. The internal consistency of the PASE-A components was good (Cronbach's alpha 0.70-0.75), and the reliability of the components was excellent (ICC 2,1 0.90-0.98). A higher PASE-A score was associated with higher grip strength ( r =0.28, p =0.05) and with shorter Timed Up and Go test times ( r =-0.45, p =0.01). The PASE-A version was easy, understandable, and relevant for Saudi older adults' culture. This scale was a reliable and valid tool for evaluating and assessing the PA level among community-dwelling older adults in Saudi Arabia.

  7. Assessment of radial torsion using computed tomography in dogs with and without antebrachial limb deformity.

    PubMed

    Kroner, Kevin; Cooley, Katie; Hoey, Seamus; Hetzel, Scott J; Bleedorn, Jason A

    2017-01-01

    To evaluate the reliability of radial torsion assessment in dogs using computed tomography (CT). Cadaveric and retrospective observational clinical study. Thoracic limbs (n = 40) from bilateral normal cadaveric canine specimens (10 pairs) and unilateral antebrachial angular limb deformity (ALD) dogs (10 uniapical and 10 biapical deformities). Limbs were evaluated using CT. Frontal, sagittal, and axial plane (torsion) values were obtained using published guidelines and compared between groups and limbs. Radial torsion reliability was assessed among 3 observers using intraclass correlation coefficients (ICC). The mean (±SD) radial torsion of normal dogs was 3.6° ± 6.4° and contained a significant right to left limb variation of 2.6°. Mean radial torsion in uniapical ALD limbs (3.6° ± 18.7°) was not significantly different from biapical ALD limbs (8.9° ± 17.9°). There was a wide range of torsion values in normal and ALD limbs. The interobserver reliability was excellent (ICC > 0.8) for normal dogs, good (0.73) for uniapical, and excellent (0.89) for biapical ALD limbs. The intraobserver reliability was excellent (>0.8) for all groups. There was a small side-to-side variation of radial torsion in normal dogs. With directed training, torsion assessment using CT is reliable in dogs with and without antebrachial bone deformity. © 2016 The American College of Veterinary Surgeons.

  8. The Reliability of Pharyngeal High Resolution Manometry with Impedance for Derivation of Measures of Swallowing Function in Healthy Volunteers

    PubMed Central

    Omari, Taher I.; Savilampi, Johanna; Kokkinn, Karmen; Schar, Mistyka; Lamvik, Kristin; Doeltgen, Sebastian; Cock, Charles

    2016-01-01

    Purpose. We evaluated the intra- and interrater agreement and test-retest reliability of analyst derivation of swallow function variables based on repeated high resolution manometry with impedance measurements. Methods. Five subjects swallowed 10 × 10 mL saline on two occasions one week apart producing a database of 100 swallows. Swallows were repeat-analysed by six observers using software. Swallow variables were indicative of contractility, intrabolus pressure, and flow timing. Results. The average intraclass correlation coefficients (ICC) for intra- and interrater comparisons of all variable means showed substantial to excellent agreement (intrarater ICC 0.85–1.00; mean interrater ICC 0.77–1.00). Test-retest results were less reliable. ICC for test-retest comparisons ranged from slight to excellent depending on the class of variable. Contractility variables differed most in terms of test-retest reliability. Amongst contractility variables, UES basal pressure showed excellent test-retest agreement (mean ICC 0.94), measures of UES postrelaxation contractile pressure showed moderate to substantial test-retest agreement (mean Interrater ICC 0.47–0.67), and test-retest agreement of pharyngeal contractile pressure ranged from slight to substantial (mean Interrater ICC 0.15–0.61). Conclusions. Test-retest reliability of HRIM measures depends on the class of variable. Measures of bolus distension pressure and flow timing appear to be more test-retest reliable than measures of contractility. PMID:27190520

  9. Use of the smartphone for end vertebra selection in scoliosis.

    PubMed

    Pepe, Murad; Kocadal, Onur; Iyigun, Abdullah; Gunes, Zafer; Aksahin, Ertugrul; Aktekin, Cem Nuri

    2017-03-01

    The aim of our study was to develop a smartphone-aided end vertebra selection method and to investigate its effectiveness in Cobb angle measurement. Twenty-nine adolescent idiopathic scoliosis patients' pre-operative posteroanterior scoliosis radiographs were used for end vertebra selection and Cobb angle measurement by standard method and smartphone-aided method. Measurements were performed by 7 examiners. The intraclass correlation coefficient was used to analyze selection and measurement reliability. Summary statistics of variance calculations were used to provide 95% prediction limits for the error in Cobb angle measurements. A paired 2-tailed t test was used to analyze end vertebra selection differences. Mean absolute Cobb angle difference was 3.6° for the manual method and 1.9° for the smartphone-aided method. Both intraobserver and interobserver reliability were found excellent in manual and smartphone set for Cobb angle measurement. Both intraobserver and interobserver reliability were found excellent in manual and smartphone set for end vertebra selection. But reliability values of manual set were lower than smartphone. Two observers selected significantly different end vertebra in their repeated selections for manual method. Smartphone-aided method for end vertebra selection and Cobb angle measurement showed excellent reliability. We can expect a reduction in measurement error rates with the widespread use of this method in clinical practice. Level III, Diagnostic study. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  10. Body surface assessment with 3D laser-based anthropometry: reliability, validation, and improvement of empirical surface formulae.

    PubMed

    Kuehnapfel, Andreas; Ahnert, Peter; Loeffler, Markus; Scholz, Markus

    2017-02-01

    Body surface area is a physiological quantity relevant for many medical applications. In clinical practice, it is determined by empirical formulae. 3D laser-based anthropometry provides an easy and effective way to measure body surface area but is not ubiquitously available. We used data from laser-based anthropometry from a population-based study to assess validity of published and commonly used empirical formulae. We performed a large population-based study on adults collecting classical anthropometric measurements and 3D body surface assessments (N = 1435). We determined reliability of the 3D body surface assessment and validity of 18 different empirical formulae proposed in the literature. The performance of these formulae is studied in subsets of sex and BMI. Finally, improvements of parameter settings of formulae and adjustments for sex and BMI were considered. 3D body surface measurements show excellent intra- and inter-rater reliability of 0.998 (overall concordance correlation coefficient, OCCC was used as measure of agreement). Empirical formulae of Fujimoto and Watanabe, Shuter and Aslani and Sendroy and Cecchini performed best with excellent concordance with OCCC > 0.949 even in subgroups of sex and BMI. Re-parametrization of formulae and adjustment for sex and BMI slightly improved results. In adults, 3D laser-based body surface assessment is a reliable alternative to estimation by empirical formulae. However, there are empirical formulae showing excellent results even in subgroups of sex and BMI with only little room for improvement.

  11. Statistics corner: A guide to appropriate use of correlation coefficient in medical research.

    PubMed

    Mukaka, M M

    2012-09-01

    Correlation is a statistical method used to assess a possible linear association between two continuous variables. It is simple both to calculate and to interpret. However, misuse of correlation is so common among researchers that some statisticians have wished that the method had never been devised at all. The aim of this article is to provide a guide to appropriate use of correlation in medical research and to highlight some misuse. Examples of the applications of the correlation coefficient have been provided using data from statistical simulations as well as real data. Rule of thumb for interpreting size of a correlation coefficient has been provided.

  12. [Correlation of molecular weight and nanofiltration mass transfer coefficient of phenolic acid composition from Salvia miltiorrhiza].

    PubMed

    Li, Cun-Yu; Wu, Xin; Gu, Jia-Mei; Li, Hong-Yang; Peng, Guo-Ping

    2018-04-01

    Based on the molecular sieving and solution-diffusion effect in nanofiltration separation, the correlation between initial concentration and mass transfer coefficient of three typical phenolic acids from Salvia miltiorrhiza was fitted to analyze the relationship among mass transfer coefficient, molecular weight and concentration. The experiment showed a linear relationship between operation pressure and membrane flux. Meanwhile, the membrane flux was gradually decayed with the increase of solute concentration. On the basis of the molecular sieving and solution-diffusion effect, the mass transfer coefficient and initial concentration of three phenolic acids showed a power function relationship, and the regression coefficients were all greater than 0.9. The mass transfer coefficient and molecular weight of three phenolic acids were negatively correlated with each other, and the order from high to low is protocatechualdehyde >rosmarinic acid> salvianolic acid B. The separation mechanism of nanofiltration for phenolic acids was further clarified through the analysis of the correlation of molecular weight and nanofiltration mass transfer coefficient. The findings provide references for nanofiltration separation, especially for traditional Chinese medicine with phenolic acids. Copyright© by the Chinese Pharmaceutical Association.

  13. The psychometric properties of an Arabic numeric pain rating scale for measuring osteoarthritis knee pain.

    PubMed

    Alghadir, Ahmad H; Anwer, Shahnawaz; Iqbal, Zaheen Ahmed

    2016-12-01

    The aims of this study were to translate the numeric rating scale (NRS) into Arabic and to evaluate the test-retest reliability and convergent validity of an Arabic Numeric Pain Rating Scale (ANPRS) for measuring pain in osteoarthritis (OA) of the knee. The English version of the NRS was translated into Arabic as per the translation process guidelines for patient-rated outcome scales. One hundred twenty-one consecutive patients with OA of the knee who had experienced pain for more than 6 months were asked to report their pain levels on the ANPRS, visual analogue scale (VAS), and verbal rating scale (VRS). A second assessment was performed 48 h after the first to assess test-retest reliability. The test-retest reliability was calculated using the intraclass correlation coefficient (ICC2,1). The convergent validity was assessed using Spearman rank correlation coefficient. In addition, the minimum detectable change (MDC) and standard error of measurement (SEM) were also assessed. The repeatability of ANPRS was good to excellent (ICC 0.89). The SEM and MDC were 0.71 and 1.96, respectively. Significant correlations were found with the VAS and VRS scores (p <0.01). The Arabic numeric pain rating scale is a valid and reliable scale for measuring pain levels in OA of the knee. Implications for Rehabilitation The Arabic Numeric Pain Rating Scale (ANPRS) is a reliable and valid instrument for measuring pain in osteoarthritis (OA) of the knee, with psychometric properties in agreement with other widely used scales. The ANPRS is well correlated with the VAS and NRS scores in patients with OA of the knee. The ANPRS appears to measure pain intensity similar to the VAS, NRS, and VRS and may provide additional advantages to Arab populations, as Arabic numbers are easily understood by this population.

  14. Outcomes and Disability After Massive Proximal Upper Extremity Reconstruction in a Resource-Limited Setting.

    PubMed

    Giladi, Aviram M; Shanmugakrishnan, R Raja; Venkatramani, Hari; Raja Sekaran, S; Chung, Kevin C; Sabapathy, S Raja

    2017-06-01

    At Ganga Hospital in Coimbatore, India, a unique approach is applied to treat massive upper limb injuries. However, long-term outcomes of complex reconstruction performed in the resource-limited setting are not known. This hinders understanding of outcomes and disability from these injuries and prevents systematically addressing care delivery around upper extremity trauma in the developing world. This project aims to analyze the details of the unique Ganga Hospital reconstruction experience and use patient-reported outcome measures for the first time in this patient population to evaluate post-injury recovery and disability . Forty-six patients were evaluated 6 months or more after massive proximal upper extremity reconstruction at Ganga Hospital. Patients completed functional tests, Jebsen-Taylor test (JTT), and patient-reported outcomes (PROs)-Michigan Hand Questionnaire (MHQ), Disability of Arm, Shoulder, and Hand questionnaire (DASH), and Short-Form 36 (SF-36). Correlations between metrics were assessed with Pearson's correlation coefficients. Linear regression modeling evaluated associations between severity, reconstruction, and outcomes. MHQ and DASH results correlated with functional test performance, JTT performance, and SF-36 scores (Pearson's coefficients all ≥0.33, p ≤ 0.05). In this cohort, mean MHQ score was 79 ± 15 and mean DASH score was 13 ± 15, which are not significantly different than scores for long-term outcomes after other complex upper extremity procedures. The following factors predicted PROs and functional performance after reconstruction: extent of soft tissue reconstruction, multi-segmental ulna fractures, median nerve injury, and ability for patients to return to work and maintain their job after injury. Complex proximal upper extremity salvage can be performed in the resource-limited setting with excellent long-term functional and patient-reported outcomes. PRO questionnaires are useful for reporting outcomes that correlate to functional and sensory testing and may be used to assess post-traumatic disability.

  15. Cross-cultural translation of the Lysholm knee score in Chinese and its validation in patients with anterior cruciate ligament injury.

    PubMed

    Wang, W; Liu, L; Chang, X; Jia, Z Y; Zhao, J Z; Xu, W D

    2016-10-19

    The Lysholm Knee Score (LKS) is widely used and is one of the most effective questionnaires employed to assess knee injuries. Although LKS has been translated into multiple languages, there is no Chinese version even though China has the largest population of patients with knee-joint injuries. The objective of our study was to develop the Chinese version of LKS (C-LKS) and assess its reliability, validity and responsiveness in Chinese patients with anterior cruciate ligament (ACL) injuries. Study participants were mainly recruited among patients with ACL injuries scheduled for arthroscopic ACL reconstruction at our hospital. First, we developed the C-LKS in a five-step translation and cross-cultural adaptation procedure. Next, we calculated the Cronbach's alpha, intraclass correlation coefficient (ICC), Pearson's correlation coefficient (r), effect size (ES), and standardized response mean (SRM) to evaluate the reliability, validity, and responsiveness of C-LKS respectively. Overall, 126 patients with ACL injuries successfully completed the questionnaires. Acceptable internal consistency (Cronbach's alpha = 0.726) as well as excellent test-retest reliability (ICC = 0.935) was found for C-LKS. Good or moderate correlation (r = 0.514-0.837) was determined among C-LKS and International Knee Documentation Committee Subjective Knee Form (IKDC), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), physical subscales of SF-36; C-LKS also had fair or moderate correlation (r = 0.207-0.462) with the other subscales of SF-36, which adequately illustrated that good validity was included in C-LKS. In addition, good responsiveness was also observed in C-LKS (ES = 1.36,SRM = 1.26). We have shown that our developed C-LKS questionnaire is reliable, valid and responsible for the evaluation of Chinese-speaking patients with ACL injuries and it would be an effective instrument.

  16. Biostatistics Series Module 6: Correlation and Linear Regression.

    PubMed

    Hazra, Avijit; Gogtay, Nithya

    2016-01-01

    Correlation and linear regression are the most commonly used techniques for quantifying the association between two numeric variables. Correlation quantifies the strength of the linear relationship between paired variables, expressing this as a correlation coefficient. If both variables x and y are normally distributed, we calculate Pearson's correlation coefficient ( r ). If normality assumption is not met for one or both variables in a correlation analysis, a rank correlation coefficient, such as Spearman's rho (ρ) may be calculated. A hypothesis test of correlation tests whether the linear relationship between the two variables holds in the underlying population, in which case it returns a P < 0.05. A 95% confidence interval of the correlation coefficient can also be calculated for an idea of the correlation in the population. The value r 2 denotes the proportion of the variability of the dependent variable y that can be attributed to its linear relation with the independent variable x and is called the coefficient of determination. Linear regression is a technique that attempts to link two correlated variables x and y in the form of a mathematical equation ( y = a + bx ), such that given the value of one variable the other may be predicted. In general, the method of least squares is applied to obtain the equation of the regression line. Correlation and linear regression analysis are based on certain assumptions pertaining to the data sets. If these assumptions are not met, misleading conclusions may be drawn. The first assumption is that of linear relationship between the two variables. A scatter plot is essential before embarking on any correlation-regression analysis to show that this is indeed the case. Outliers or clustering within data sets can distort the correlation coefficient value. Finally, it is vital to remember that though strong correlation can be a pointer toward causation, the two are not synonymous.

  17. Biostatistics Series Module 6: Correlation and Linear Regression

    PubMed Central

    Hazra, Avijit; Gogtay, Nithya

    2016-01-01

    Correlation and linear regression are the most commonly used techniques for quantifying the association between two numeric variables. Correlation quantifies the strength of the linear relationship between paired variables, expressing this as a correlation coefficient. If both variables x and y are normally distributed, we calculate Pearson's correlation coefficient (r). If normality assumption is not met for one or both variables in a correlation analysis, a rank correlation coefficient, such as Spearman's rho (ρ) may be calculated. A hypothesis test of correlation tests whether the linear relationship between the two variables holds in the underlying population, in which case it returns a P < 0.05. A 95% confidence interval of the correlation coefficient can also be calculated for an idea of the correlation in the population. The value r2 denotes the proportion of the variability of the dependent variable y that can be attributed to its linear relation with the independent variable x and is called the coefficient of determination. Linear regression is a technique that attempts to link two correlated variables x and y in the form of a mathematical equation (y = a + bx), such that given the value of one variable the other may be predicted. In general, the method of least squares is applied to obtain the equation of the regression line. Correlation and linear regression analysis are based on certain assumptions pertaining to the data sets. If these assumptions are not met, misleading conclusions may be drawn. The first assumption is that of linear relationship between the two variables. A scatter plot is essential before embarking on any correlation-regression analysis to show that this is indeed the case. Outliers or clustering within data sets can distort the correlation coefficient value. Finally, it is vital to remember that though strong correlation can be a pointer toward causation, the two are not synonymous. PMID:27904175

  18. A comparison of confidence interval methods for the intraclass correlation coefficient in community-based cluster randomization trials with a binary outcome.

    PubMed

    Braschel, Melissa C; Svec, Ivana; Darlington, Gerarda A; Donner, Allan

    2016-04-01

    Many investigators rely on previously published point estimates of the intraclass correlation coefficient rather than on their associated confidence intervals to determine the required size of a newly planned cluster randomized trial. Although confidence interval methods for the intraclass correlation coefficient that can be applied to community-based trials have been developed for a continuous outcome variable, fewer methods exist for a binary outcome variable. The aim of this study is to evaluate confidence interval methods for the intraclass correlation coefficient applied to binary outcomes in community intervention trials enrolling a small number of large clusters. Existing methods for confidence interval construction are examined and compared to a new ad hoc approach based on dividing clusters into a large number of smaller sub-clusters and subsequently applying existing methods to the resulting data. Monte Carlo simulation is used to assess the width and coverage of confidence intervals for the intraclass correlation coefficient based on Smith's large sample approximation of the standard error of the one-way analysis of variance estimator, an inverted modified Wald test for the Fleiss-Cuzick estimator, and intervals constructed using a bootstrap-t applied to a variance-stabilizing transformation of the intraclass correlation coefficient estimate. In addition, a new approach is applied in which clusters are randomly divided into a large number of smaller sub-clusters with the same methods applied to these data (with the exception of the bootstrap-t interval, which assumes large cluster sizes). These methods are also applied to a cluster randomized trial on adolescent tobacco use for illustration. When applied to a binary outcome variable in a small number of large clusters, existing confidence interval methods for the intraclass correlation coefficient provide poor coverage. However, confidence intervals constructed using the new approach combined with Smith's method provide nominal or close to nominal coverage when the intraclass correlation coefficient is small (<0.05), as is the case in most community intervention trials. This study concludes that when a binary outcome variable is measured in a small number of large clusters, confidence intervals for the intraclass correlation coefficient may be constructed by dividing existing clusters into sub-clusters (e.g. groups of 5) and using Smith's method. The resulting confidence intervals provide nominal or close to nominal coverage across a wide range of parameters when the intraclass correlation coefficient is small (<0.05). Application of this method should provide investigators with a better understanding of the uncertainty associated with a point estimator of the intraclass correlation coefficient used for determining the sample size needed for a newly designed community-based trial. © The Author(s) 2015.

  19. Establishing the reliability and concurrent validity of physical performance tests using virtual reality equipment for community-dwelling healthy elders.

    PubMed

    Griswold, David; Rockwell, Kyle; Killa, Carri; Maurer, Michael; Landgraff, Nancy; Learman, Ken

    2015-01-01

    The aim of this study was to determine the reliability and concurrent validity of commonly used physical performance tests using the OmniVR Virtual Rehabilitation System for healthy community-dwelling elders. Participants (N = 40) were recruited by the authors and were screened for eligibility. The initial method of measurement was randomized to either virtual reality (VR) or clinically based measures (CM). Physical performance tests included the five times sit to stand, Timed Up and Go (TUG), Forward Functional Reach (FFR) and 30-s stand test. A random number generator determined the testing order. The test-re-test reliability for the VR and CM was determined. Furthermore, concurrent validity was determined using a Pearson product moment correlation (Pearson r). The VR demonstrated excellent reliability for 5 × STS intraclass correlation coefficient (ICC) = 0.931(3,1), FFR ICC = 0.846(3,1) and the TUG ICC = 0.944(3,1). The concurrent validity data for the VR and CM (ICC 3, k) were moderate for FFR ICC = 0.682, excellent 5 × STS ICC = 0.889 and excellent for the TUG ICC = 0.878. The concurrent validity of the 30-s stand test was good ICC = 0.735(3,1). This study supports the use of VR equipment for measuring physical performance tests in the clinic for healthy community-dwelling elders. Virtual reality equipment is not only used to treat balance impairments but it is also used to measure and determine physical impairments through the use of physical performance tests. Virtual reality equipment is a reliable and valid tool for collecting physical performance data for the 5 × STS, FFR, TUG and 30-s stand test for healthy community-dwelling elders.

  20. Snapping Sharks, Maddening Mindreaders, and Interactive Images: Teaching Correlation.

    ERIC Educational Resources Information Center

    Mitchell, Mark L.

    Understanding correlation coefficients is difficult for students. A free computer program that helps introductory psychology students distinguish between positive and negative correlation, and which also teaches them to understand the differences between correlation coefficients of different size is described in this paper. The program is…

  1. Expression of Bcl-2, Melan A and HMB-45 in Dysplastic Nevi.

    PubMed

    Patrascu, Oana Maria; Costache, Mariana; Dumitru, Adrian Vasile; Mehotin, Corina Nicoleta; Sajin, Maria; Lazaroiu, Anca Mihaela

    2016-03-01

    From the first recognition of dysplastic nevi as a pathology per se, many debates have been raised and many histological and immunohistological studies have been conducted in order to establish the true significance of these lesions. Therefore, the aim of this study was to establish if there is a correlation between HMB-45, Melan A and Bcl-2 expression and the grade of dysplasia, as well as between the marker's staining patterns. Ten dysplastic nevi from six female patients were selected and their histological features (size, dysplasia), as well as the immunohistological staining patterns, were studied (HMB-45, Melan A, Bcl-2). The Pearson correlation coefficient and regression was calculated with Windows Excel Data Analysis. We demonstrated that there was a notable correlation between the dysplasia and the size of the lesions (r(8)= 0.62 with p-value= 0.052), and also between Melan A and Bcl-2 (a r(6)= 0.73, p<0.05), but we did not obtain a statistically significant correlation between other features (p>0.05). We can affirm, at least in our cases, there is a correlation between the grade of dysplasia and the size of the lesion, and also, that there is a correlation between Melan A and Bcl-2 staining, explained by MITF gene. These results were only partial concordant with those in other studies, therefore a larger number of cases is recommended to be further analyzed in order to clearly draw a conclusion.

  2. 40 CFR 53.34 - Test procedure for methods for PM10 and Class I methods for PM2.5.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... linear regression parameters (slope, intercept, and correlation coefficient) describing the relationship... correlation coefficient. (2) To pass the test for comparability, the slope, intercept, and correlation...

  3. [Prediction of soil adsorption coefficients of organic compounds in a wide range of soil types by soil column liquid chromatography].

    PubMed

    Guo, Rongbo; Chen, Jiping; Zhang, Qing; Wu, Wenzhong; Liang, Xinmiao

    2004-01-01

    Using the methanol-water mixtures as mobile phases of soil column liquid chromatography (SCLC), prediction of soil adsorption coefficients (K(d)) by SCLC was validated in a wide range of soil types. The correlations between the retention factors measured by SCLC and soil adsorption coefficients measured by batch experiments were studied for five soils with different properties, i.e., Eurosoil 1#, 2#, 3#, 4# and 5#. The results show that good correlations existed between the retention factors and soil adsorption coefficients for Eurosoil 1#, 2#, 3# and 4#. For Eurosoil 5# which has a pH value of near 3, the correlation between retention factors and soil adsorption coefficients was unsatisfactory using methanol-water as mobile phase of SCLC. However, a good correlation was obtained using a methanol-buffer mixture with pH 3 as the mobile phase. This study proved that the SCLC is suitable for the prediction of soil adsorption coefficients.

  4. The influence of surface roughness and solution concentration on pool boiling process in Diethanolamine aqueous solution

    NASA Astrophysics Data System (ADS)

    Khoshechin, Mohsen; Salimi, Farhad; Jahangiri, Alireza

    2018-04-01

    In this research, the effect of surface roughness and concentration of solution on bubble departing frequency and nucleation site density for pool boiling of water/diethanolamine (DEA) binary solution were investigated experimentally. In this investigation, boiling heat transfer coefficient, bubble departing frequency and nucleation site density have been experimentally investigated in various concentrations and heat fluxes. Microstructured surfaces with a wide range of well-defined surface roughness were fabricated, and a heat flux between 1.5-86 kW/m2 was achieved under atmospheric conditions. The Results indicated that surface roughness and concentration of solution increase the bubble departing frequency and nucleation site density with increasing heat flux. The boiling heat transfer coefficient in mixtures of water/DEA increases with increasing concentration of DEA in water. The experimental results were compared with predictions of several used correlations in the literatures. Results showed that the boiling heat transfer coefficients of this case study are much higher than the predicted values by major existing correlations and models. The excellent agreement for bubble departing frequency found between the models of Jackob and Fritz (1966) and experimental data and also the nucleation site density were in close agreement with the model of Paul (1983) data. f bubble departure frequency, 1/s or Hz N Number of nucleation sites per area per time R c Minimum cavity size, m D c critical diameter, m g gravitational acceleration, m/s2 ρ density, kg/m3 T temperature, °c ΔT temperature difference, °c d d vapor bubble diameter, m h fg enthalpy of vaporization, J/kg R Roughness, μm Ja Jakob number cp specific heat, J/kg °c Pr Prandtl number Ar Archimedes number h Heat transfer coefficient, J/(m2 °c) tg time it takes to grow a bubble, s q/A heat flux (kW/m2) tw time required to heat the layer, s gc Correction coefficient of incompatible units R a Surface roughness A heated surface area d departure ONB onset of nucleate boiling w surface wall s saturation v vapor l liquid θ groove angle (o) γ influence parameter of heating surface material σ surface tension, N/m.

  5. Reliability and validity of the Dutch pediatric Voice Handicap Index.

    PubMed

    Veder, Laura; Pullens, Bas; Timmerman, Marieke; Hoeve, Hans; Joosten, Koen; Hakkesteegt, Marieke

    2017-05-01

    The pediatric voice handicap index (pVHI) has been developed to provide a better insight into the parents' perception of their child's voice related quality of life. The purpose of the present study was to validate the Dutch pVHI by evaluating its internal consistency and reliability. Furthermore, we determined the optimal cut-off point for a normal pVHI score. All items of the English pVHI were translated into Dutch. Parents of children in our dysphonic and control group were asked to fill out the questionnaire. For the test re-test analysis we used a different study group who filled out the pVHI twice as part of a large follow up study. Internal consistency was analyzed through Cronbach's α coefficient. The test-retest reliability was assessed by determining Pearson's correlation coefficient. Mann-Whitney test was used to compare the scores of the questionnaire of the control group with the dysphonic group. By calculating receiver operating characteristic (ROC) curves, sensitivity and specificity we were able to set a cut-off point. We obtained data from 122 asymptomatic children and from 79 dysphonic children. The scores of the questionnaire significantly differed between both groups. The internal consistency showed an overall Cronbach α coefficient of 0.96 and an excellent test-retest reliability of the total pVHI questionnaire with a Pearson's correlation coefficient of 0.90. A cut-off point for the total pVHI questionnaire was set at 7 points with a specificity of 85% and sensitivity of 100%. A cut-off point for the VAS score was set at 13 with a specificity of 93% and sensitivity of 97%. The Dutch pVHI is a valid and reliable tool for the assessment of children with voice problems. By setting a cut-off point for the score of the total pVHI questionnaire of 7 points and the VAS score of 13, the pVHI might be used as a screening tool to assess dysphonic complaints and the pVHI might be a useful and complementary tool to identify children with dysphonia. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Determination of n-octanol/water partition coefficient for DDT-related compounds by RP-HPLC with a novel dual-point retention time correction.

    PubMed

    Han, Shu-ying; Qiao, Jun-qin; Zhang, Yun-yang; Yang, Li-li; Lian, Hong-zhen; Ge, Xin; Chen, Hong-yuan

    2011-03-01

    n-Octanol/water partition coefficients (P) for DDTs and dicofol were determined by reversed-phase high performance liquid chromatography (RP-HPLC) on a C(18) column using methanol-water mixture as mobile phase. A dual-point retention time correction (DP-RTC) was proposed to rectify chromatographic retention time (t(R)) shift resulted from stationary phase aging. Based on this correction, the relationship between logP and logk(w), the logarithm of the retention factor extrapolated to pure water, was investigated for a set of 12 benzene homologues and DDT-related compounds with reliable experimental P as model compounds. A linear regression logP=(1.10±0.04) logk(w) - (0.60±0.17) was established with correlation coefficient R(2) of 0.988, cross-validated correlation coefficient R(cv)(2) of 0.983 and standard deviation (SD) of 0.156. This model was further validated using four verification compounds, naphthalene, biphenyl, 2,2-bis(4-chlorophenyl)-1,1-dichloroethane (p,p'-DDD) and 2,2-bis(4-chlorophenyl)-1,1-dichloroethene (p,p'-DDE) with similar structure to DDT. The RP-HPLC-determined P values showed good consistency with shake-flask (SFM) or slow-stirring (SSM) results, especially for highly hydrophobic compounds with logP in the range of 4-7. Then, the P values for five DDT-related compounds, 2-(2-chlorophenyl)-2-(4-chlorophenyl)-1,1,1-trichloroethane (o,p'-DDT), 2-(2-chlorophenyl)-2-(4-chlorophenyl)-1,1-dichloroethane (o,p'-DDD), 2-(2-chlorophenyl)-2-(4-chlorophenyl)-1,1-dichloroethene (o,p'-DDE), and 2,2,2-trichloro-1,1-bis(4-chlorophenyl)ethanol (dicofol) and its main degradation product 4,4'-dichlorobenzophenone (p,p'-DBP) were evaluated by the improved RP-HPLC method for the first time. The excellent precision with SD less than 0.03 proved that the novel DP-RTC protocol can significantly increases the determination accuracy and reliability of P by RP-HPLC. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Precision analysis of a quantitative CT liver surface nodularity score.

    PubMed

    Smith, Andrew; Varney, Elliot; Zand, Kevin; Lewis, Tara; Sirous, Reza; York, James; Florez, Edward; Abou Elkassem, Asser; Howard-Claudio, Candace M; Roda, Manohar; Parker, Ellen; Scortegagna, Eduardo; Joyner, David; Sandlin, David; Newsome, Ashley; Brewster, Parker; Lirette, Seth T; Griswold, Michael

    2018-04-26

    To evaluate precision of a software-based liver surface nodularity (LSN) score derived from CT images. An anthropomorphic CT phantom was constructed with simulated liver containing smooth and nodular segments at the surface and simulated visceral and subcutaneous fat components. The phantom was scanned multiple times on a single CT scanner with adjustment of image acquisition and reconstruction parameters (N = 34) and on 22 different CT scanners from 4 manufacturers at 12 imaging centers. LSN scores were obtained using a software-based method. Repeatability and reproducibility were evaluated by intraclass correlation (ICC) and coefficient of variation. Using abdominal CT images from 68 patients with various stages of chronic liver disease, inter-observer agreement and test-retest repeatability among 12 readers assessing LSN by software- vs. visual-based scoring methods were evaluated by ICC. There was excellent repeatability of LSN scores (ICC:0.79-0.99) using the CT phantom and routine image acquisition and reconstruction parameters (kVp 100-140, mA 200-400, and auto-mA, section thickness 1.25-5.0 mm, field of view 35-50 cm, and smooth or standard kernels). There was excellent reproducibility (smooth ICC: 0.97; 95% CI 0.95, 0.99; CV: 7%; nodular ICC: 0.94; 95% CI 0.89, 0.97; CV: 8%) for LSN scores derived from CT images from 22 different scanners. Inter-observer agreement for the software-based LSN scoring method was excellent (ICC: 0.84; 95% CI 0.79, 0.88; CV: 28%) vs. good for the visual-based method (ICC: 0.61; 95% CI 0.51, 0.69; CV: 43%). Test-retest repeatability for the software-based LSN scoring method was excellent (ICC: 0.82; 95% CI 0.79, 0.84; CV: 12%). The software-based LSN score is a quantitative CT imaging biomarker with excellent repeatability, reproducibility, inter-observer agreement, and test-retest repeatability.

  8. Characterization of Severe Arterial Phase Respiratory Motion Artifact on Gadoxetate Disodium-Enhanced MRI - Assessment of Interrater Agreement and Reliability.

    PubMed

    Ringe, Kristina Imeen; Luetkens, Julian A; Fimmers, Rolf; Hammerstingl, Renate Maria; Layer, Günter; Maurer, Martin H; Nähle, Claas Philip; Michalik, Sabine; Reimer, Peter; Schraml, Christina; Schreyer, Andreas G; Stumpp, Patrick; Vogl, Thomas J; Wacker, Frank K; Willinek, Winfried; Kukuk, Guido Mattias

    2018-04-01

     To assess the interrater agreement and reliability of experienced abdominal radiologists in the characterization and grading of arterial phase gadoxetate disodium-related respiratory motion artifact on liver MRI.  This prospective multicenter study was initiated by the working group for abdominal imaging within the German Roentgen Society (DRG), and approved by the local IRB of each participating center. 11 board-certified radiologists independently reviewed 40 gadoxetate disodium-enhanced liver MRI datasets. Motion artifacts in the arterial phase were assessed on a 5-point scale. Interrater agreement and reliability were calculated using the intraclass correlation coefficient (ICC) and Kendall coefficient of concordance (W), with p < 0.05 deemed significant.  The ICC for interrater agreement and reliability were 0.983 (CI 0.973 - 0.990) and 0.985 (CI 0.978 - 0.991), respectively (both p < 0.0001), indicating excellent agreement and reliability. Kendall's W for interrater agreement was 0.865. A severe motion artifact, defined as a mean motion score ≥ 4 in the arterial phase was observed in 12 patients. In these specific cases, a motion score ≥ 4 was assigned by all readers in 75 % (n = 9/12 cases).  Differentiation and grading of arterial phase respiratory motion artifact is possible with a high level of inter-/intrarater agreement and interrater reliability, which is crucial for assessing the incidence of this phenomenon in larger multicenter studies.   · Inter- and intrarater agreement for motion artifact scoring is excellent among experienced readers.. · Interrater reliability for motion artifact scoring is excellent among experienced readers.. · Characterization of severe motion artifacts proved feasible in this multicenter study.. · Ringe KI, Luetkens JA, Fimmers R et al. Characterization of Severe Arterial Phase Respiratory Motion Artifact on Gadoxetate Disodium-Enhanced MRI - Assessment of Interrater Agreement and Reliability. Fortschr Röntgenstr 2017; 190: 341 - 347. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Temporal correlation coefficient for directed networks.

    PubMed

    Büttner, Kathrin; Salau, Jennifer; Krieter, Joachim

    2016-01-01

    Previous studies dealing with network theory focused mainly on the static aggregation of edges over specific time window lengths. Thus, most of the dynamic information gets lost. To assess the quality of such a static aggregation the temporal correlation coefficient can be calculated. It measures the overall possibility for an edge to persist between two consecutive snapshots. Up to now, this measure is only defined for undirected networks. Therefore, we introduce the adaption of the temporal correlation coefficient to directed networks. This new methodology enables the distinction between ingoing and outgoing edges. Besides a small example network presenting the single calculation steps, we also calculated the proposed measurements for a real pig trade network to emphasize the importance of considering the edge direction. The farm types at the beginning of the pork supply chain showed clearly higher values for the outgoing temporal correlation coefficient compared to the farm types at the end of the pork supply chain. These farm types showed higher values for the ingoing temporal correlation coefficient. The temporal correlation coefficient is a valuable tool to understand the structural dynamics of these systems, as it assesses the consistency of the edge configuration. The adaption of this measure for directed networks may help to preserve meaningful additional information about the investigated network that might get lost if the edge directions are ignored.

  10. Correlation characteristics of phase and amplitude chimeras in an ensemble of nonlocally coupled maps

    NASA Astrophysics Data System (ADS)

    Vadivasova, T. E.; Strelkova, G. I.; Bogomolov, S. A.; Anishchenko, V. S.

    2017-01-01

    Correlation characteristics of chimera states have been calculated using the coefficient of mutual correlation of elements in a closed-ring ensemble of nonlocally coupled chaotic maps. Quantitative differences between the coefficients of mutual correlation for phase and amplitude chimeras are established for the first time.

  11. The relationship between the Nasality Severity Index 2.0 and perceptual judgments of hypernasality.

    PubMed

    Bettens, Kim; De Bodt, Marc; Maryn, Youri; Luyten, Anke; Wuyts, Floris L; Van Lierde, Kristiane M

    2016-01-01

    The Nasality Severity Index 2.0 (NSI 2.0) forms a new, multiparametric approach in the identification of hypernasality. The present study aimed to investigate the correlation between the NSI 2.0 scores and the perceptual assessment of hypernasality. Speech samples of 35 patients, representing a range of nasality from normal to severely hypernasal, were rated by four expert speech-language pathologists using visual analogue scaling (VAS) judging the degree of hypernasality, audible nasal airflow (ANA) and speech intelligibility. Inter- and intra-listener reliability was verified using intraclass correlation coefficients. Correlations between NSI 2.0 scores and its parameters (i.e. nasalance score of an oral text and vowel /u/, voice low tone to high tone ratio of the vowel /i/) and the degree of hypernasality were determined using Pearson correlation coefficients. Multiple linear regression analysis was used to investigate the possible influence of ANA and speech intelligibility on the NSI 2.0 scores. Overall good to excellent inter- and intra-listener reliability was found for the perceptual ratings. A moderate, but significant negative correlation between NSI 2.0 scores and perceived hypernasality (r=-0.64) was found, in which a more negative NSI 2.0 score indicates the presence of more severe hypernasality. No significant influence of ANA or intelligibility on the NSI 2.0 was observed based on the regression analysis. Because the NSI 2.0 correlates significantly with perceived hypernasality, it provides an easy-to-interpret severity score of hypernasality which will facilitate the evaluation of therapy outcomes, communication to the patient and other clinicians, and decisions for treatment planning, based on a multiparametric approach. However, research is still necessary to further explore the instrumental correlates of perceived hypernasality. The reader will be able to (1) describe and discuss current issues and influencing variables regarding perceptual ratings of hypernasality; (2) describe and discuss the relationship between the Nasality Severity Index 2.0, a new multiparametric approach to hypernasality, and perceptual judgments of hypernasality based on visual analogue scale ratings; (3) compare these results with the correlations based on a single parameter approach and (4) describe and discuss the possible influence of audible nasal airflow and speech intelligibility on the NSI 2.0 scores. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Comparison of RNFL thickness and RPE-normalized RNFL attenuation coefficient for glaucoma diagnosis

    NASA Astrophysics Data System (ADS)

    Vermeer, K. A.; van der Schoot, J.; Lemij, H. G.; de Boer, J. F.

    2013-03-01

    Recently, a method to determine the retinal nerve fiber layer (RNFL) attenuation coefficient, based on normalization on the retinal pigment epithelium, was introduced. In contrast to conventional RNFL thickness measures, this novel measure represents a scattering property of the RNFL tissue. In this paper, we compare the RNFL thickness and the RNFL attenuation coefficient on 10 normal and 8 glaucomatous eyes by analyzing the correlation coefficient and the receiver operator curves (ROCs). The thickness and attenuation coefficient showed moderate correlation (r=0.82). Smaller correlation coefficients were found within normal (r=0.55) and glaucomatous (r=0.48) eyes. The full separation between normal and glaucomatous eyes based on the RNFL attenuation coefficient yielded an area under the ROC (AROC) of 1.0. The AROC for the RNFL thickness was 0.9875. No statistically significant difference between the two measures was found by comparing the AROC. RNFL attenuation coefficients may thus replace current RNFL thickness measurements or be combined with it to improve glaucoma diagnosis.

  13. Photosynthesis of alfalfa (Medicago sativa) in response to landfill leachate contamination.

    PubMed

    Yang, Lie; Sun, Tiantian; Liu, Yanli; Guo, Houqing; Lv, Lixin; Zhang, Jie; Liu, Chang

    2017-11-01

    Thousands of unlined landfills and open dumpsites have put great threat on the security of soil and ground water due to leachate leakage. Alfalfa is believed potential as a phytoremediation plant for leachate contamination based on strong root system and the excellent capacity of removing various kinds of pollutants. A lab-scale investigation was conducted to figure out the sensitiveness of alfalfa photosynthesis in response to leachate contamination. The results demonstrated that both of the maximum photosynthetic efficiency (F v /F m ) and net photosynthetic rate (P n ) were slightly inhibited in the high-dosage group. Based on statistical analysis, higher sensitivity of P n to leaching parameters than F v /F m was observed. There were significant correlations between most of leaching parameters (pH, ammonium and COD) and P n with correlation coefficients of 0.530, -0.580 and -0.578 (p < 0.01), respectively. Therefore, P n is potential for acting as an effective indicator for staple leaching characteristics of leachate contaminated soils. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Response surface optimization of the critical medium components for pullulan production by Aureobasidium pullulans FB-1.

    PubMed

    Singh, Ram Sarup; Singh, Harpreet; Saini, Gaganpreet Kaur

    2009-01-01

    Culture conditions for pullulan production by Aureobasidium pullulans were optimized using response surface methodology at shake flask level without pH control. In the present investigation, a five-level with five-factor central composite rotatable design of experiments was employed to optimize the levels of five factors significantly affecting the pullulan production, biomass production, and sugar utilization in submerged cultivation. The selected factors included concentration of sucrose, ammonium sulphate, yeast extract, dipotassium hydrogen phosphate, and sodium chloride. Using this methodology, the optimal values for concentration of sucrose, ammonium sulphate, yeast extract, dipotassium hydrogen phosphate, and sodium chloride were 5.31%, 0.11%, 0.07%, 0.05%, and 0.15% (w/v), respectively. This optimized medium has projected a theoretically production of pullulan of 4.44%, biomass yield of 1.03%, and sugar utilization of 97.12%. The multiple correlation coefficient 'R' was 0.9976, 0.9761 and 0.9919 for pullulan production, biomass production, and sugar utilization, respectively. The value of R being very close to one justifies an excellent correlation between the predicted and the experimental data.

  15. Effects of fragility and reduced glass transition temperature on the glass formation ability of amorphous alloys

    NASA Astrophysics Data System (ADS)

    Xu, Xiao-Jin; Long, Zhi-Lin; Liu, Wei; Liao, Guang-Kai

    2017-11-01

    In this paper, based on the reduced glass transition temperature ({{T}rg} ) proposed by Turnbull and the relation between the glass-forming ability (GFA) and the short-range bond ordering of liquids demonstrated by Tanaka, a detailed analysis on the specific roles of {{T}rg} and fragility of the glass forming liquid (m) in characterizing the GFA has been conducted, and then a novel GFA parameter α [=2/3× (100{{T}rg}{)}-(16/100)× m=67{{T}rg}-0.16m] was put forward. This new GFA parameter α , which increases with a decrease in the critical cooling rate (R c) for glass formation, is a complex function of {{T}rg} and m. The relationship between R c and the parameter α was identified and verified using available literature data for broad range of amorphous alloys with widely varying GFA. The correlation coefficient (R 2) of 0.9 clearly shows an excellent correlation between GFA and the parameter α and that α is a more superior indicator compared to currently reported similar GFA parameters.

  16. Raman spectroscopy based screening of IgG positive and negative sera for dengue virus infection

    NASA Astrophysics Data System (ADS)

    Bilal, M.; Saleem, M.; Bial, Maria; Khan, Saranjam; Ullah, Rahat; Ali, Hina; Ahmed, M.; Ikram, Masroor

    2017-11-01

    A quantitative analysis for the screening of immunoglobulin-G (IgG) positive human sera samples is presented for the dengue virus infection. The regression model was developed using 79 samples while 20 samples were used to test the performance of the model. The R-square (r 2) value of 0.91 was found through a leave-one-sample-out cross validation method, which shows the validity of this model. This model incorporates the molecular changes associated with IgG. Molecular analysis based on regression coefficients revealed that myristic acid, coenzyme-A, alanine, arabinose, arginine, vitamin C, carotene, fumarate, galactosamine, glutamate, lactic acid, stearic acid, tryptophan and vaccenic acid are positively correlated with IgG; while amide III, collagen, proteins, fatty acids, phospholipids and fucose are negatively correlated. For blindly tested samples, an excellent agreement has been found between the model predicted, and the clinical values of IgG. The parameters, which include sensitivity, specificity, accuracy and the area under the receiver operator characteristic curve, are found to be 100%, 83.3%, 95% and 0.99, respectively, which confirms the high quality of the model.

  17. Quantification of the effects of quality investment on the Cost of Poor Quality: A quasi-experimental study

    NASA Astrophysics Data System (ADS)

    Tamimi, Abdallah Ibrahim

    Quality management is a fundamental challenge facing businesses. This research attempted to quantify the effect of quality investment on the Cost of Poor Quality (COPQ) in an aerospace company utilizing 3 years of quality data at United Launch Alliance, a Boeing -- Lockheed Martin Joint Venture Company. Statistical analysis tools, like multiple regressions, were used to quantify the relationship between quality investments and COPQ. Strong correlations were evident by the high correlation coefficient R2 and very small p-values in multiple regression analysis. The models in the study helped produce an Excel macro that based on preset constraints, optimized the level of quality spending to minimize COPQ. The study confirmed that as quality investments were increased, the COPQ decreased steadily until a point of diminishing return was reached. The findings may be used to develop an approach to reduce the COPQ and enhance product performance. Achieving superior quality in rocket launching enhances the accuracy, reliability, and mission success of delivering satellites to their precise orbits in pursuit of knowledge, peace, and freedom while assuring safety for the end user.

  18. Acoustically active injection catheter guided by ultrasound: navigation tests in acutely ischemic porcine hearts.

    PubMed

    Belohlavek, Marek; Katayama, Minako; Zarbatany, David; Fortuin, F David; Fatemi, Mostafa; Nenadic, Ivan Z; McMahon, Eileen M

    2014-07-01

    Catheters are increasingly used therapeutically and investigatively. With complex usage comes a need for more accurate intracardiac localization than traditional guidance can provide. An injection catheter navigated by ultrasound was designed and then tested in an open-chest model of acute ischemia in eight pigs. The catheter is made "acoustically active" by a piezo-electric crystal near its tip, electronically controlled, vibrating in the audio frequency range and uniquely identifiable using pulsed-wave Doppler. Another "target" crystal was sutured to the epicardium within the ischemic region. Sonomicrometry was used to measure distances between the two crystals and then compared with measurements from 2-D echocardiographic images. Complete data were obtained from seven pigs, and the correlation between sonomicrometry and ultrasound measurements was excellent (p < 0.0001, ρ = 0.9820), as was the intraclass correlation coefficient (0.96) between two observers. These initial experimental results suggest high accuracy of ultrasound navigation of the acoustically active catheter prototype located inside the beating left ventricle. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  19. Channel correlation of free space optical communication systems with receiver diversity in non-Kolmogorov atmospheric turbulence

    NASA Astrophysics Data System (ADS)

    Ma, Jing; Fu, Yulong; Tan, Liying; Yu, Siyuan; Xie, Xiaolong

    2018-05-01

    Spatial diversity as an effective technique to mitigate the turbulence fading has been widely utilized in free space optical (FSO) communication systems. The received signals, however, will suffer from channel correlation due to insufficient spacing between component antennas. In this paper, the new expressions of the channel correlation coefficient and specifically its components (the large- and small-scale channel correlation coefficients) for a plane wave with aperture effects are derived for horizontal link in moderate-to-strong turbulence, using a non-Kolmogorov spectrum that has a generalized power law in the range of 3-4 instead of the fixed classical Kolmogorov power law of 11/3. And then the influence of power law variations on the channel correlation coefficient and its components are analysed. The numerical results indicated that various value of the power law lead to varying effects on the channel correlation coefficient and its components. This work will help with the further investigation on the fading correlation in spatial diversity systems.

  20. The Physical Significance of the Synthetic Running Correlation Coefficient and Its Applications in Oceanic and Atmospheric Studies

    NASA Astrophysics Data System (ADS)

    Zhao, Jinping; Cao, Yong; Wang, Xin

    2018-06-01

    In order to study the temporal variations of correlations between two time series, a running correlation coefficient (RCC) could be used. An RCC is calculated for a given time window, and the window is then moved sequentially through time. The current calculation method for RCCs is based on the general definition of the Pearson product-moment correlation coefficient, calculated with the data within the time window, which we call the local running correlation coefficient (LRCC). The LRCC is calculated via the two anomalies corresponding to the two local means, meanwhile, the local means also vary. It is cleared up that the LRCC reflects only the correlation between the two anomalies within the time window but fails to exhibit the contributions of the two varying means. To address this problem, two unchanged means obtained from all available data are adopted to calculate an RCC, which is called the synthetic running correlation coefficient (SRCC). When the anomaly variations are dominant, the two RCCs are similar. However, when the variations of the means are dominant, the difference between the two RCCs becomes obvious. The SRCC reflects the correlations of both the anomaly variations and the variations of the means. Therefore, the SRCCs from different time points are intercomparable. A criterion for the superiority of the RCC algorithm is that the average value of the RCC should be close to the global correlation coefficient calculated using all data. The SRCC always meets this criterion, while the LRCC sometimes fails. Therefore, the SRCC is better than the LRCC for running correlations. We suggest using the SRCC to calculate the RCCs.

  1. Measurement properties of the Dizziness Handicap Inventory by cross-sectional and longitudinal designs

    PubMed Central

    2009-01-01

    Background The impact of dizziness on quality of life is often assessed by the Dizziness Handicap Inventory (DHI), which is used as a discriminate and evaluative measure. The aim of the present study was to examine reliability and validity of a translated Norwegian version (DHI-N), also examining responsiveness to important change in the construct being measured. Methods Two samples (n = 92 and n = 27) included participants with dizziness of mainly vestibular origin. A cross-sectional design was used to examine the factor structure (exploratory factor analysis), internal consistency (Cronbach's α), concurrent validity (Pearson's product moment correlation r), and discriminate ability (ROC curve analysis). Longitudinal designs were used to examine test-retest reliability (intraclass correlation coefficient (ICC) statistics, smallest detectable difference (SDD)), and responsiveness (Pearson's product moment correlation, ROC curve analysis; area under the ROC curve (AUC), and minimally important change (MIC)). The DHI scores range from 0 to 100. Results Factor analysis revealed a different factor structure than the original DHI, resulting in dismissal of subscale scores in the DHI-N. Acceptable internal consistency was found for the total scale (α = 0.95). Concurrent correlations between the DHI-N and other related measures were moderate to high, highest with Vertigo Symptom Scale-short form-Norwegian version (r = 0.69), and lowest with preferred gait (r = - 0.36). The DHI-N demonstrated excellent ability to discriminate between participants with and without 'disability', AUC being 0.89 and best cut-off point = 29 points. Satisfactory test-retest reliability was demonstrated, and the change for an individual should be ≥ 20 DHI-N points to exceed measurement error (SDD). Correlations between change scores of DHI-N and other self-report measures of functional health and symptoms were high (r = 0.50 - 0.57). Responsiveness of the DHI-N was excellent, AUC = 0.83, discriminating between self-perceived 'improved' versus 'unchanged' participants. The MIC was identified as 11 DHI-N points. Conclusions The DHI-N total scale demonstrated satisfactory measurement properties. This is the first study that has addressed and demonstrated responsiveness to important change of the DHI, and provided values of SDD and MIC to help interpret change scores. PMID:20025754

  2. Computational prediction of ionic liquid 1-octanol/water partition coefficients.

    PubMed

    Kamath, Ganesh; Bhatnagar, Navendu; Baker, Gary A; Baker, Sheila N; Potoff, Jeffrey J

    2012-04-07

    Wet 1-octanol/water partition coefficients (log K(ow)) predicted for imidazolium-based ionic liquids using adaptive bias force-molecular dynamics (ABF-MD) simulations lie in excellent agreement with experimental values. These encouraging results suggest prospects for this computational tool in the a priori prediction of log K(ow) values of ionic liquids broadly with possible screening implications as well (e.g., prediction of CO(2)-philic ionic liquids).

  3. High test-retest-reliability of pain-related evoked potentials (PREP) in healthy subjects.

    PubMed

    Özgül, Özüm Simal; Maier, Christoph; Enax-Krumova, Elena K; Vollert, Jan; Fischer, Marc; Tegenthoff, Martin; Höffken, Oliver

    2017-04-24

    Pain-related evoked potentials (PREP) is an established electrophysiological method to evaluate the signal transmission of electrically stimulated A-delta fibres. Although prerequisite for its clinical use, test-retest-reliability and side-to-side differences of bilateral stimulation in healthy subjects have not been examined yet. We performed PREP twice within 3-14days in 33 healthy subjects bilaterally by stimulating the dorsal hand. Detection (DT) and pain thresholds (PT) after electrical stimulation, the corresponding pain ratings, latencies of P0, N1, P1 and N2 components and the corresponding amplitudes were assessed. Impact of electrically induced pain intensity, age, sex, and arm length on PREP was analysed. MANOVA, t-Test, interclass correlation coefficient (ICC), standard error of measurement (SEM), smallest real difference (SRD), Bland-Altmann-Analysis as well as ANCOVA were used for statistical analysis. Measurement from both sides on both days resulted in mean N1-latencies from 142.39±18.12ms to 144.03±16.62ms and in mean N1P1-amplitudes from 39.04±12.26μV to 40.53±12.9μV. Analysis of a side-to-side effect showed for the N1-latency a F-value of 0.038 and for the N1P1-amplitude of 0.004 (p>0.8). We found intraclass correlation coefficients (ICC) from 0.88 to 0.93 and a standard error of measurement (SEM)<10% of mean values for all measurements concerning the N1-Latency and N1P1-amplitude. Intraclass correlation coefficients, standard error of measurement and Bland-Altman-Analyses revealed excellent test-retest-reliability for N1-latency and N1P1-amplitude without systematic error and there was no side-to-side effect on PREP. N1-latency (r=0.35, p<0.05) and N1P1-amplitude (r=-0.45, p<0.05) correlated with age and additionally N1-latency correlated with arm length (r=0.45, p<0.001). In contrast, pain intensity during the stimulation had no effect on both N1-latency and N1P1-amplitude. In summary, PREP showed high test-retest-reliability and negligible side-to-side differences concerning the commonly used parameters N1-latency and N1P1-amplitude. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Observed intra-cluster correlation coefficients in a cluster survey sample of patient encounters in general practice in Australia

    PubMed Central

    Knox, Stephanie A; Chondros, Patty

    2004-01-01

    Background Cluster sample study designs are cost effective, however cluster samples violate the simple random sample assumption of independence of observations. Failure to account for the intra-cluster correlation of observations when sampling through clusters may lead to an under-powered study. Researchers therefore need estimates of intra-cluster correlation for a range of outcomes to calculate sample size. We report intra-cluster correlation coefficients observed within a large-scale cross-sectional study of general practice in Australia, where the general practitioner (GP) was the primary sampling unit and the patient encounter was the unit of inference. Methods Each year the Bettering the Evaluation and Care of Health (BEACH) study recruits a random sample of approximately 1,000 GPs across Australia. Each GP completes details of 100 consecutive patient encounters. Intra-cluster correlation coefficients were estimated for patient demographics, morbidity managed and treatments received. Intra-cluster correlation coefficients were estimated for descriptive outcomes and for associations between outcomes and predictors and were compared across two independent samples of GPs drawn three years apart. Results Between April 1999 and March 2000, a random sample of 1,047 Australian general practitioners recorded details of 104,700 patient encounters. Intra-cluster correlation coefficients for patient demographics ranged from 0.055 for patient sex to 0.451 for language spoken at home. Intra-cluster correlations for morbidity variables ranged from 0.005 for the management of eye problems to 0.059 for management of psychological problems. Intra-cluster correlation for the association between two variables was smaller than the descriptive intra-cluster correlation of each variable. When compared with the April 2002 to March 2003 sample (1,008 GPs) the estimated intra-cluster correlation coefficients were found to be consistent across samples. Conclusions The demonstrated precision and reliability of the estimated intra-cluster correlations indicate that these coefficients will be useful for calculating sample sizes in future general practice surveys that use the GP as the primary sampling unit. PMID:15613248

  5. Effect of double-layer polarization on the forces that act on a nanosized cylindrical particle in an ac electrical field.

    PubMed

    Zhao, Hui; Bau, Haim H

    2008-06-17

    The polarization of, the forces acting on, and the electroosmotic flow field around a cylindrical particle of radius a* and uniform zeta potential zeta* submerged in an electrolyte solution and subjected to alternating electric fields are computed by solving the Poisson-Nernst-Planck (PNP) equations (the standard model). The dipole coefficient and the electrostatic and hydrodynamic forces are calculated as functions of the electric field's frequency, the solute concentration, and the particle's surface charge. The calculations are not restricted to small Debye screening lengths (lambdaD*). At relatively low frequencies, the polarization coefficient is nearly frequency-independent. As the frequency increases above D*/a*(2), where D* is the effective diffusion coefficient, the polarization coefficient initially increases, attains a maximum, and then decreases to an asymptotic value (when the frequency exceeds (1+Du)D*/lambdaD(*2), where Du is the Dukhin number). At low frequencies, when (lambdaD*/a*)(2)e(|zeta*F*/(2R*T*)|) < 1, the PNP calculations are in excellent agreement with the predictions of the Dukhin-Shilov (DS) low-frequency theory. At high frequencies, when lambda D*/a* < 1, the PNP calculations are in excellent agreement with the Maxwell-Wagner-O'Konski (MWO) theory.

  6. Feature Genes Selection Using Supervised Locally Linear Embedding and Correlation Coefficient for Microarray Classification

    PubMed Central

    Wang, Yun; Huang, Fangzhou

    2018-01-01

    The selection of feature genes with high recognition ability from the gene expression profiles has gained great significance in biology. However, most of the existing methods have a high time complexity and poor classification performance. Motivated by this, an effective feature selection method, called supervised locally linear embedding and Spearman's rank correlation coefficient (SLLE-SC2), is proposed which is based on the concept of locally linear embedding and correlation coefficient algorithms. Supervised locally linear embedding takes into account class label information and improves the classification performance. Furthermore, Spearman's rank correlation coefficient is used to remove the coexpression genes. The experiment results obtained on four public tumor microarray datasets illustrate that our method is valid and feasible. PMID:29666661

  7. Feature Genes Selection Using Supervised Locally Linear Embedding and Correlation Coefficient for Microarray Classification.

    PubMed

    Xu, Jiucheng; Mu, Huiyu; Wang, Yun; Huang, Fangzhou

    2018-01-01

    The selection of feature genes with high recognition ability from the gene expression profiles has gained great significance in biology. However, most of the existing methods have a high time complexity and poor classification performance. Motivated by this, an effective feature selection method, called supervised locally linear embedding and Spearman's rank correlation coefficient (SLLE-SC 2 ), is proposed which is based on the concept of locally linear embedding and correlation coefficient algorithms. Supervised locally linear embedding takes into account class label information and improves the classification performance. Furthermore, Spearman's rank correlation coefficient is used to remove the coexpression genes. The experiment results obtained on four public tumor microarray datasets illustrate that our method is valid and feasible.

  8. Atom-type-based AI topological descriptors: application in structure-boiling point correlations of oxo organic compounds.

    PubMed

    Ren, Biye

    2003-01-01

    Structure-boiling point relationships are studied for a series of oxo organic compounds by means of multiple linear regression (MLR) analysis. Excellent MLR models based on the recently introduced Xu index and the atom-type-based AI indices are obtained for the two subsets containing respectively 77 ethers and 107 carbonyl compounds and a combined set of 184 oxo compounds. The best models are tested using the leave-one-out cross-validation and an external test set, respectively. The MLR model produces a correlation coefficient of r = 0.9977 and a standard error of s = 3.99 degrees C for the training set of 184 compounds, and r(cv) = 0.9974 and s(cv) = 4.16 degrees C for the cross-validation set, and r(pred) = 0.9949 and s(pred) = 4.38 degrees C for the prediction set of 21 compounds. For the two subsets containing respectively 77 ethers and 107 carbonyl compounds, the quality of the models is further improved. The standard errors are reduced to 3.30 and 3.02 degrees C, respectively. Furthermore, the results obtained from this study indicate that the boiling points of the studied oxo compound dominantly depend on molecular size and also depend on individual atom types, especially oxygen heteroatoms in molecules due to strong polar interactions between molecules. These excellent structure-boiling point models not only provide profound insights into the role of structural features in a molecule but also illustrate the usefulness of these indices in QSPR/QSAR modeling of complex compounds.

  9. Reliability and validity of Arabic Rapid Estimate of Adult Literacy in Dentistry (AREALD-30) in Saudi Arabia.

    PubMed

    Tadakamadla, Santosh Kumar; Quadri, Mir Faeq Ali; Pakpour, Amir H; Zailai, Abdulaziz M; Sayed, Mohammed E; Mashyakhy, Mohammed; Inamdar, Aadil S; Tadakamadla, Jyothi

    2014-09-29

    To evaluate the reliability and validity of Arabic Rapid Estimate of Adult Literacy in Dentistry (AREALD-30) in Saudi Arabia. A convenience sample of 200 subjects was approached, of which 177 agreed to participate giving a response rate of 88.5%. Rapid Estimate of Adult Literacy in Dentistry (REALD-99), was translated into Arabic to prepare the longer and shorter versions of Arabic Rapid Estimate of Adult Literacy in Dentistry (AREALD-99 and AREALD-30). Each participant was provided with AREALD-99 which also includes words from AREALD-30. A questionnaire containing socio-behavioral information and Arabic Oral Health Impact Profile (A-OHIP-14) was also administered. Reliability of the AREALD-30 was assessed by re-administering it to 20 subjects after two weeks. Convergent and predictive validity of AREALD-30 was evaluated by its correlations with AREALD-99 and self-perceived oral health status, dental visiting habits and A-OHIP-14 respectively. Discriminant validity was assessed in relation to the educational level while construct validity was evaluated by confirmatory factor analysis (CFA). Reliability of AREALD-30 was excellent with intraclass correlation coefficient of 0.99. It exhibited good convergent and discriminant validity but poor predictive validity. CFA showed presence of two factors and infit mean-square statistics for AREALD-30 were all within the desired range of 0.50 - 2.0 in Rasch analysis. AREALD-30 showed excellent reliability, good convergent and concurrent validity, but failed to predict the differences between the subjects categorized based on their oral health outcomes.

  10. The Drug Abuse Screening Test preserves its excellent psychometric properties in psychiatric patients evaluated in an emergency setting.

    PubMed

    Giguère, Charles-Édouard; Potvin, Stéphane

    2017-01-01

    Substance use disorders (SUDs) are significant risk factors for psychiatric relapses and hospitalizations in psychiatric populations. Unfortunately, no instrument has been validated for the screening of SUDs in psychiatric emergency settings. The Drug Abuse Screening Test (DAST) is widely used in the addiction field, but is has not been validated in that particular context. The objective of the current study is to examine the psychometric properties of the DAST administered to psychiatric populations evaluated in an emergency setting. The DAST was administered to 912 psychiatric patients in an emergency setting, of which 119 had a SUD (excluding those misusing alcohol only). The internal consistency, the construct validity, the test-retest reliability and the predictive validity (using SUD diagnoses) of the DAST were examined. The convergent validity was also examined, using a validated impulsivity scale. Regarding the internal consistency of the DAST, the Cronbach's alpha was 0.88. The confirmatory factor analysis showed that the DAST has one underlying factor. The test-retest reliability analysis produced a correlation coefficient of 0.86. ROC curve analyses produced an area under the curve of 0.799. Interestingly, a sex effect was observed. Finally, the convergent validity analysis showed that the DAST total score is specifically correlated with the sensation seeking dimension of impulsivity. The results of this validation study shows that the DAST preserves its excellent psychometric properties in psychiatric populations evaluated in an emergency setting. These results should encourage the use of the DAST in this unstable clinical situation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Comparison between Carotid Artery Wall Thickness Measured by Multidetector Row Computed Tomography Angiography and Intimae-Media Thickness Measured by Sonography

    PubMed Central

    Savić, Živorad N.; Soldatović, Ivan I.; Brajović, Milan D.; Pavlović, Aleksandra M.; Mladenović, Dušan R.; Škodrić-Trifunović, Vesna D.

    2011-01-01

    The increased thickness of the carotid wall >1 mm is a significant predictor of coronary and cerebrovascular diseases. The purpose of our study was to assess the agreement between multidetector row computed tomography angiography (MDCTA) in measuring carotid artery wall thickness (CAWT) and color Doppler ultrasound (CD-US) in measuring intimae-media thickness (IMT). Eighty-nine patients (aged 35–81) were prospectively analyzed using a 64-detector MDCTA and a CD-US scanner. Continuous data were described as the mean value ± standard deviation, and were compared using the Mann–Whitney U test. A p value <0.05 was considered significant. Bland–Altman statistics were employed to measure the agreement between MDCTA and CD-US. CAWT ranged from 0.62 to 1.60 mm, with a mean value of 1.09 mm. IMT ranged from 0.60 to 1.55 mm, with a mean value of 1.06 mm. We observed an excellent agreement between CD-US and MDCTA in the evaluation of the common carotid artery thickness, with a bias between methods of 0.029 mm (which is a highly statistically important difference of absolute values [t = 43.289; p < 0.01] obtained by paired T test), and limits of agreement from 0.04 to 0.104. Pearson correlation coefficient was 0.9997 (95% CI 0.9996–0.9998; p < 0.01). We conclude that there is an excellent correlation between CAWT and IMT measurements obtained with the MDCTA and CD-US. PMID:22224072

  12. A Comparison of Three Methods for the Analysis of Skin Flap Viability: Reliability and Validity.

    PubMed

    Tim, Carla Roberta; Martignago, Cintia Cristina Santi; da Silva, Viviane Ribeiro; Dos Santos, Estefany Camila Bonfim; Vieira, Fabiana Nascimento; Parizotto, Nivaldo Antonio; Liebano, Richard Eloin

    2018-05-01

    Objective: Technological advances have provided new alternatives to the analysis of skin flap viability in animal models; however, the interrater validity and reliability of these techniques have yet to be analyzed. The present study aimed to evaluate the interrater validity and reliability of three different methods: weight of paper template (WPT), paper template area (PTA), and photographic analysis. Approach: Sixteen male Wistar rats had their cranially based dorsal skin flap elevated. On the seventh postoperative day, the viable tissue area and the necrotic area of the skin flap were recorded using the paper template method and photo image. The evaluation of the percentage of viable tissue was performed using three methods, simultaneously and independently by two raters. The analysis of interrater reliability and viability was performed using the intraclass correlation coefficient and Bland Altman Plot Analysis was used to visualize the presence or absence of systematic bias in the evaluations of data validity. Results: The results showed that interrater reliability for WPT, measurement of PTA, and photographic analysis were 0.995, 0.990, and 0.982, respectively. For data validity, a correlation >0.90 was observed for all comparisons made between the three methods. In addition, Bland Altman Plot Analysis showed agreement between the comparisons of the methods and the presence of systematic bias was not observed. Innovation: Digital methods are an excellent choice for assessing skin flap viability; moreover, they make data use and storage easier. Conclusion: Independently from the method used, the interrater reliability and validity proved to be excellent for the analysis of skin flaps' viability.

  13. Pearson's Correlation between Three Variables; Using Students' Basic Knowledge of Geometry for an Exercise in Mathematical Statistics

    ERIC Educational Resources Information Center

    Vos, Pauline

    2009-01-01

    When studying correlations, how do the three bivariate correlation coefficients between three variables relate? After transforming Pearson's correlation coefficient r into a Euclidean distance, undergraduate students can tackle this problem using their secondary school knowledge of geometry (Pythagoras' theorem and similarity of triangles).…

  14. Validation of the Inventaire du Milieu Familial Questionnaire (French version of the Infant/Toddler HOME) into the Brazilian Portuguese language.

    PubMed

    Sudbrack, Simone; Barbosa, Fernanda P; Mattiello, Rita; Booij, Linda; Estorgato, Geovana R; Dutra, Moisés S; Assunção, Fabiana D de; Nunes, Magda L

    2018-04-22

    To validate the Brazilian Portuguese version of the Family Environment Assessment questionnaire (Inventaire du Milieu Familial). The validation process was carried out in two stages. First, translation and back-translation were performed, and in the second phase, the questionnaire was applied in 72 families of children between 0 and 24 months for the validation process. The tool consists of the following domains: mother's communication ability; behavior; organization of the physical and temporal environment; collection/quantity of toys; maternal attitude of constant attention toward her baby; diversification of stimuli; baby's behavior. The following was performed for the scale validation: 1 - content analysis (judgment); 2 - construct analysis (factorial analysis - Kaiser-Meyer-Olkin, Bartlett, and Pearson's correlation tests); 3 - criterion analysis (calculation of Cronbach's alpha coefficient, intraclass correlations, and split-half correlations). The mean age of the children was 9±6.7 months, and of these, 35 (48.6%) were males. Most correlations between items and domains were significant. In the factorial analysis of the scale, Kaiser-Meyer-Olkin values were 0.76, Bartlett's test showed a p-value<0.001, and correlation between items and domains showed a p-value<0.01. Regarding the validity, Cronbach's alpha was 0.92 (95% CI: 0.89-0.94). The intraclass correlation among the evaluators was 0.97 (0.96-0.98) and split-half correlations, r: 0.60, with p<0.01. The Portuguese version of the Inventaire du Milieu Familial showed good to excellent performance regarding the assessed psychometric properties. Copyright © 2018. Published by Elsevier Editora Ltda.

  15. Preliminary validation and reliability of the Short Form Chronic Respiratory Disease Questionnaire in a lung cancer population.

    PubMed

    Charalambous, A; Molassiotis, A

    2017-01-01

    The Short Form Chronic Respiratory Questionnaire (SF-CRQ) is frequently used in patients with obstructive pulmonary disease and it has demonstrated excellent psychometric properties. Since there is no psychometric information for its use with lung cancer patients, this study explored its validity and reliability in this population. Forty-six patients were assessed at two time points (with a 4-week interval) using the SF-CRQ, the modified Borg Scale, five numerical rating scales related to Perceived Severity of Breathlessness, and the Hospital Anxiety and Depression Scale. Internal consistency reliability was investigated by Cronbach's alpha reliability coefficient, test-retest reliability by Spearman-Brown reliability coefficient (P), content validity as well as convergent validity by Pearson's correlation coefficient between the SF-CRQ, and the conceptual similar scales mentioned above were explored. A principal component factor analysis was performed. The internal consistency was high [α = 0.88 (baseline) and 0.91 (after 1 month)]. The SF-CRQ had good stability with test-retest reliability ranging from r = 0.64 to 0.78, P < 0.001. Factor analysis suggests a single construct in this population. The preliminary data analyses supported the convergent, content, and construct validity of the SF-CRQ providing promising evidence that this can be a valid and reliable instrument for the assessment of quality of life related to breathlessness in lung cancer patients. © 2015 John Wiley & Sons Ltd.

  16. Development, scoring, and reliability of the Microscale Audit of Pedestrian Streetscapes (MAPS)

    PubMed Central

    2013-01-01

    Background Streetscape (microscale) features of the built environment can influence people’s perceptions of their neighborhoods’ suitability for physical activity. Many microscale audit tools have been developed, but few have published systematic scoring methods. We present the development, scoring, and reliability of the Microscale Audit of Pedestrian Streetscapes (MAPS) tool and its theoretically-based subscales. Methods MAPS was based on prior instruments and was developed to assess details of streetscapes considered relevant for physical activity. MAPS sections (route, segments, crossings, and cul-de-sacs) were scored by two independent raters for reliability analyses. There were 290 route pairs, 516 segment pairs, 319 crossing pairs, and 53 cul-de-sac pairs in the reliability sample. Individual inter-rater item reliability analyses were computed using Kappa, intra-class correlation coefficient (ICC), and percent agreement. A conceptual framework for subscale creation was developed using theory, expert consensus, and policy relevance. Items were grouped into subscales, and subscales were analyzed for inter-rater reliability at tiered levels of aggregation. Results There were 160 items included in the subscales (out of 201 items total). Of those included in the subscales, 80 items (50.0%) had good/excellent reliability, 41 items (25.6%) had moderate reliability, and 18 items (11.3%) had low reliability, with limited variability in the remaining 21 items (13.1%). Seventeen of the 20 route section subscales, valence (positive/negative) scores, and overall scores (85.0%) demonstrated good/excellent reliability and 3 demonstrated moderate reliability. Of the 16 segment subscales, valence scores, and overall scores, 12 (75.0%) demonstrated good/excellent reliability, three demonstrated moderate reliability, and one demonstrated poor reliability. Of the 8 crossing subscales, valence scores, and overall scores, 6 (75.0%) demonstrated good/excellent reliability, and 2 demonstrated moderate reliability. The cul-de-sac subscale demonstrated good/excellent reliability. Conclusions MAPS items and subscales predominantly demonstrated moderate to excellent reliability. The subscales and scoring system represent a theoretically based framework for using these complex microscale data and may be applicable to other similar instruments. PMID:23621947

  17. Apparent diffusion coefficient of breast cancer and normal fibroglandular tissue in diffusion-weighted imaging: the effects of menstrual cycle and menopausal status.

    PubMed

    Kim, Jin You; Suh, Hie Bum; Kang, Hyun Jung; Shin, Jong Ki; Choo, Ki Seok; Nam, Kyung Jin; Lee, Seok Won; Jung, Young Lae; Bae, Young Tae

    2016-05-01

    The purpose of this study was to investigate prospectively whether the apparent diffusion coefficients (ADCs) of both breast cancer and normal fibroglandular tissue vary with the menstrual cycle and menopausal status. Institutional review board approval was obtained, and informed consent was obtained from each participant. Fifty-seven women (29 premenopausal, 28 postmenopausal) with newly diagnosed breast cancer underwent diffusion-weighted imaging twice (interval 12-20 days) before surgery. Two radiologists independently measured ADC of breast cancer and normal contralateral breast tissue, and we quantified the differences according to the phases of menstrual cycle and menopausal status. With normal fibroglandular tissue, ADC was significantly lower in postmenopausal than in premenopausal women (P = 0.035). In premenopausal women, ADC did not differ significantly between proliferative and secretory phases in either breast cancer or normal fibroglandular tissue (P = 0.969 and P = 0.519, respectively). In postmenopausal women, no significant differences were found between ADCs measured at different time intervals in either breast cancer or normal fibroglandular tissue (P = 0.948 and P = 0.961, respectively). The within-subject variability of the ADC measurements was quantified using the coefficient of variation (CV) and was small: the mean CVs of tumor ADC were 2.90 % (premenopausal) and 3.43 % (postmenopausal), and those of fibroglandular tissue ADC were 4.37 % (premenopausal) and 2.55 % (postmenopausal). Both intra- and interobserver agreements were excellent for ADC measurements, with intraclass correlation coefficients in the range of 0.834-0.974. In conclusion, the measured ADCs of breast cancer and normal fibroglandular tissue were not affected significantly by menstrual cycle, and the measurements were highly reproducible both within and between observers.

  18. The protein binding substance Ibuprofen does not affect the T1 time or partition coefficient in contrast-enhanced cardiovascular magnetic resonance

    PubMed Central

    2012-01-01

    Background Contrast enhanced cardiovascular magnetic resonance (CMR) with T1 mapping enables quantification of diffuse myocardial fibrosis. Various factors, however, can interfere with T1 measurements. The purpose of the current study was to assess the effect of co-medication with a typical protein binding drug (Ibuprofen) on T1 values in vitro and in vivo. Methods 50 vials were prepared with different concentrations of gadobenate dimeglumine, Ibuprofen and human serum albumin in physiologic NaCl solution and imaged at 1.5T with a spin echo sequence at multiple TRs to measure T1 values and calculate relaxivities. 10 volunteers (5 men; 31±6.3 years) were imaged at 1.5T. T1 values for myocardium and blood pool were determined for various time points after administration of 0.15mmol/kg gadobenate dimeglumine using a modified look-locker inversion-recovery sequence before and after administration of Ibuprofen over 24 hours. The partition coefficient was calculated as ΔR1myocardium/ΔR1blood, where R1=1/T1. Results In vitro no significant correlation was found between relaxivity and Ibuprofen concentration, neither in absence (r=−0.15, p=0.40) nor in presence of albumin (r=−0.32, p=0.30). In vivo there was no significant difference in post contrast T1 times of myocardium and blood, respectively and also in the partition coefficient between exam 1 and 2 (p>0.05). There was good agreement of the T1 times of myocardium and blood and the partition coefficient, respectively between exam 1 and 2. Conclusions Contrast enhanced T1 mapping is unaffected by co-medication with the protein binding substance Ibuprofen and has an excellent reproducibility. PMID:23067266

  19. Intra-rater and inter-rater reliability of ultrasonographic measurements of acromion-greater tuberosity distance in patients with post-stroke hemiplegia.

    PubMed

    Kumar, Praveen; Cruziah, Reynold; Bradley, Michael; Gray, Selena; Swinkels, Annette

    2016-06-01

    Glenohumeral subluxation (GHS) is reported in up to 81% of patients with stroke. Ultrasonographic measurements of GHS by measuring the acromion-greater tuberosity (AGT) have been found to be reliable for experienced raters. The primary aim was to assess the intra-rater reliability of measurements of AGT distance in people with stroke following a short course of rater training. A secondary aim was to compare the inter-rater reliability of these measurements between novice and experienced raters. Patients with stroke (n = 16; 5 men, 11 women; 74 ± 10 years) with 1-sided weakness who gave informed consent were recruited. Ultrasonographic measurements were recorded at the bedside by two physiotherapists with patients seated upright in a hospital chair. Reliability was assessed by intra-class correlation coefficients (ICCs) and the standard error of measurements (SEM). Minimum detectable change (MDC90) scores were used to estimate the magnitude of change that is likely to exceed measurement error. Mean ± SD AGT distances on the affected and unaffected sides for rater 1 were 2.2 ± 0.7 and 1.7 ± 0.4 cm, respectively. Corresponding values for rater 2 were 2.5 ± 0.6 and 2.0 ± 0.4 cm. Intra-class correlation coefficient values for the affected and unaffected shoulders for rater 1 were 0.96 and 0.91, respectively. Corresponding values for rater 2 were 0.95 and 0.90.SEM and MDC90 for both affected and unaffected shoulders were ≤ 0.2 cm. Inter-rater reliability coefficients were 0.86 (affected) and 0.76 (unaffected) shoulders. Ultrasonographic measurement of AGT distance demonstrates excellent intra-rater reliability for a novice rater. Inter-rater reliability of ultrasonographic measurement of AGT also demonstrates good reliability between novice and experienced raters.

  20. Reliability of laser Doppler flowmetry curve reading for measurement of toe and ankle pressures: intra- and inter-observer variation.

    PubMed

    Høyer, C; Paludan, J P D; Pavar, S; Biurrun Manresa, J A; Petersen, L J

    2014-03-01

    To assess the intra- and inter-observer variation in laser Doppler flowmetry curve reading for measurement of toe and ankle pressures. A prospective single blinded diagnostic accuracy study was conducted on 200 patients with known or suspected peripheral arterial disease (PAD), with a total of 760 curve sets produced. The first curve reading for this study was performed by laboratory technologists blinded to clinical clues and previous readings at least 3 months after the primary data sampling. The pressure curves were later reassessed following another period of at least 3 months. Observer agreement in diagnostic classification according to TASC-II criteria was quantified using Cohen's kappa. Reliability was quantified using intra-class correlation coefficients, coefficients of variance, and Bland-Altman analysis. The overall agreement in diagnostic classification (PAD/not PAD) was 173/200 (87%) for intra-observer (κ = .858) and 175/200 (88%) for inter-observer data (κ = .787). Reliability analysis confirmed excellent correlation for both intra- and inter-observer data (ICC all ≥.931). The coefficients of variance ranged from 2.27% to 6.44% for intra-observer and 2.39% to 8.42% for inter-observer data. Subgroup analysis showed lower observer-variation for reading of toe pressures in patients with diabetes and/or chronic kidney disease than patients not diagnosed with these conditions. Bland-Altman plots showed higher variation in toe pressure readings than ankle pressure readings. This study shows substantial intra- and inter-observer agreement in diagnostic classification and reading of absolute pressures when using laboratory technologists as observers. The study emphasises that observer variation for curve reading is an important factor concerning the overall reproducibility of the method. Our data suggest diabetes and chronic kidney disease have an influence on toe pressure reproducibility. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Validation of the Spanish Version of the Eating Assessment Tool-10 (EAT-10spa) in Colombia. A Blinded Prospective Cohort Study.

    PubMed

    Giraldo-Cadavid, Luis Fernando; Gutiérrez-Achury, Alejandra María; Ruales-Suárez, Karem; Rengifo-Varona, Maria Leonor; Barros, Camilo; Posada, Andrés; Romero, Carlos; Galvis, Ana María

    2016-06-01

    Dysphagia might affect 12 % of the general population, and its complications include pneumonia, malnutrition, social isolation, and death. No validated Spanish symptom survey exists to quantify dysphagia symptoms among Latin Americans. Therefore, we performed a prospective cohort study in a tertiary care university hospital to validate the Spanish version of the 10-Item Eating-Assessment-Tool (EAT-10spa) for use in Colombia. After an interdisciplinary committee of five bilingual specialists evaluated the EAT-10spa (translated and validated in Spain) and deemed it appropriate for the Colombian culture, its feasibility, reliability, validity, sensitivity to change, and diagnostic capacity were evaluated. As a reference standard, we used the flexible endoscopic evaluation of swallowing with sensory testing and a standardized clinical evaluation. All assessments were blinded. In total, 133 subjects were included (52 % women, mean age 55 years) and completed the EAT-10spa (median completion time: 2 min [IQR 1-3 min]), 39 % of whom had an elementary-level education. Cronbach's α coefficient: 0.91; test-retest intra-class correlation coefficient: 0.94. The Spearman's correlation coefficient of the EAT-10spa with the 8-point penetration-aspiration scale was 0.54 (P < 0.001). The area under the receiver-operating-characteristic-curve (AUC-ROC) for dysphagia and aspiration were 0.79 (P < 0.001) and 0.81 (P < 0.001), respectively. The best cut-off points for dysphagia and aspiration were EAT-10spa ≥2 (sensitivity 93.6 %, specificity 36.4 %) and EAT-10spa ≥4 (sensitivity 94.3 %, specificity 49.5 %), respectively. A reduction in the EAT-10 ≥3 was the best cut-off point for a clinically significant improvement (AUC-ROC 0.83; P < 0.0001). The EAT-10spa showed excellent psychometric properties and discriminatory capacity for use in Colombia.

  2. The use of combined thermal/pressure polyvinylidene fluoride film airflow sensor in polysomnography.

    PubMed

    Kryger, Meir; Eiken, Todd; Qin, Li

    2013-12-01

    The technologies recommended by the American Academy of Sleep Medicine (AASM) to monitor airflow in polysomnography (PSG) include the simultaneous monitoring of two physical variables: air temperature (for thermal airflow) and air pressure (for nasal pressure). To comply with airflow monitoring standards in the sleep lab setting thus often requires the patient to wear two sensors under the nose during testing. We hypothesized that a single combined thermal/pressure sensor using polyvinylidene fluoride (PVDF) film responsive to both airflow temperature and pressure would be effective in documenting abnormal breathing events during sleep. Sixty patients undergoing routine PSG testing to rule out obstructive sleep apnea at two different sleep laboratories were asked to wear a third PVDF airflow sensor in addition to the traditional thermal sensor and pressure sensor. Apnea and hypopnea events were scored by the sleep lab technologists using the AASM guidelines (CMS option) using the thermal sensor for apnea and the pressure sensor for hypopnea (scorer 1). The digital PSG data were also forwarded to an outside registered polysomnographic technologist for scoring of respiratory events detected in the PVDF airflow channels (scorer 2). The Pearson correlation coefficient, r, between apnea and hypopnea indices obtained using the AASM sensors and the combined PVDF sensor was almost unity for the four calculated indices: apnea-hypopnea index (0.990), obstructive apnea index (0.992), hypopnea index (0.958), and central apnea index (1.0). The slope of the four relationships was virtually unity and the coefficient of determination (r (2)) was also close to 1. The results of intraclass correlation coefficients (>0.95) and Bland-Altman plots also provide excellent agreement between the combined PVDF sensor and the AASM sensors. The indices used to calculate apnea severity obtained with the combined PVDF thermal and pressure sensor were equivalent to those obtained using AASM-recommended sensors.

  3. Measurement properties of the WOMAC LK 3.1 pain scale.

    PubMed

    Stratford, P W; Kennedy, D M; Woodhouse, L J; Spadoni, G F

    2007-03-01

    The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) is applied extensively to patients with osteoarthritis of the hip or knee. Previous work has challenged the validity of its physical function scale however an extensive evaluation of its pain scale has not been reported. Our purpose was to estimate internal consistency, factorial validity, test-retest reliability, and the standard error of measurement (SEM) of the WOMAC LK 3.1 pain scale. Four hundred and seventy-four patients with osteoarthritis of the hip or knee awaiting arthroplasty were administered the WOMAC. Estimates of internal consistency (coefficient alpha), factorial validity (confirmatory factor analysis), and the SEM based on internal consistency (SEM(IC)) were obtained. Test-retest reliability [Type 2,1 intraclass correlation coefficients (ICC)] and a corresponding SEM(TRT) were estimated on a subsample of 36 patients. Our estimates were: internal consistency alpha=0.84; SEM(IC)=1.48; Type 2,1 ICC=0.77; SEM(TRT)=1.69. Confirmatory factor analysis failed to support a single factor structure of the pain scale with uncorrelated error terms. Two comparable models provided excellent fit: (1) a model with correlated error terms between the walking and stairs items, and between night and sit items (chi2=0.18, P=0.98); (2) a two factor model with walking and stairs items loading on one factor, night and sit items loading on a second factor, and the standing item loading on both factors (chi2=0.18, P=0.98). Our examination of the factorial structure of the WOMAC pain scale failed to support a single factor and internal consistency analysis yielded a coefficient less than optimal for individual patient use. An alternate strategy to summing the five-item responses when considering individual patient application would be to interpret item responses separately or to sum only those items which display homogeneity.

  4. Two-Way Gene Interaction From Microarray Data Based on Correlation Methods.

    PubMed

    Alavi Majd, Hamid; Talebi, Atefeh; Gilany, Kambiz; Khayyer, Nasibeh

    2016-06-01

    Gene networks have generated a massive explosion in the development of high-throughput techniques for monitoring various aspects of gene activity. Networks offer a natural way to model interactions between genes, and extracting gene network information from high-throughput genomic data is an important and difficult task. The purpose of this study is to construct a two-way gene network based on parametric and nonparametric correlation coefficients. The first step in constructing a Gene Co-expression Network is to score all pairs of gene vectors. The second step is to select a score threshold and connect all gene pairs whose scores exceed this value. In the foundation-application study, we constructed two-way gene networks using nonparametric methods, such as Spearman's rank correlation coefficient and Blomqvist's measure, and compared them with Pearson's correlation coefficient. We surveyed six genes of venous thrombosis disease, made a matrix entry representing the score for the corresponding gene pair, and obtained two-way interactions using Pearson's correlation, Spearman's rank correlation, and Blomqvist's coefficient. Finally, these methods were compared with Cytoscape, based on BIND, and Gene Ontology, based on molecular function visual methods; R software version 3.2 and Bioconductor were used to perform these methods. Based on the Pearson and Spearman correlations, the results were the same and were confirmed by Cytoscape and GO visual methods; however, Blomqvist's coefficient was not confirmed by visual methods. Some results of the correlation coefficients are not the same with visualization. The reason may be due to the small number of data.

  5. Short forms of the Child Perceptions Questionnaire for 11–14-year-old children (CPQ11–14): Development and initial evaluation

    PubMed Central

    Jokovic, Aleksandra; Locker, David; Guyatt, Gordan

    2006-01-01

    Background The Child Perceptions Questionnaire for children aged 11 to 14 years (CPQ11–14) is a 37-item measure of oral-health-related quality of life (OHRQoL) encompassing four domains: oral symptoms, functional limitations, emotional and social well-being. To facilitate its use in clinical settings and population-based health surveys, it was shortened to 16 and 8 items. Item impact and stepwise regression methods were used to produce each version. This paper describes the developmental process, compares the discriminative properties of the resulting four short-forms and evaluates their precision relative to the original CPQ11–14. Methods The item impact method used data from the CPQ11–14 item reduction study to select the questions with the highest impact scores in each domain. The regression method, where the dependent variable was the overall CPQ11–14 score and the independent variables its individual questions, was applied to the data collected in the validity study for the CPQ11–14. The measurement properties (i.e. criterion validity, construct validity, internal consistency reliability and test-retest reliability) of all 4 short-forms were evaluated using the data from the validity and reliability studies for the CPQ11–14. Results All short forms detected substantial variability in children's OHRQoL. The mean scores on the two 16-item questionnaires were almost identical, while on the two 8-item questionnaires they differed by only one score point. The mean scores standardized to 0–100 were higher on the short forms than the original CPQ11–14 (p < 0.001). There were strong significant correlations between all short-form scores and CPQ11–14 scores (0.87–0.98; p < 0.001). Hypotheses concerning construct validity were confirmed: the short-forms' scores were highest in the oro-facial, lower in the orthodontic and lowest in the paediatric dentistry group; all short-form questionnaires were positively correlated with the ratings of oral health and overall well-being, with the correlation coefficient being higher for the latter. The relative validity coefficients were 0.85 to 1.18. Cronbach's alpha and intraclass correlation coefficients ranged 0.71–0.83 and 0.71–0.77, respectively. Conclusion All short forms demonstrated excellent criterion validity and good construct validity. The reliability coefficients exceeded standards for group-level comparisons. However, these are preliminary findings based on the convenience sampling and further testing in replicated studies involving clinical and general samples of children in various settings is necessary to establish measurement sensitivity and discriminative properties of these questionnaires. PMID:16423298

  6. Experimental studies by complementary terahertz techniques and semi-classical calculations of N2- broadening coefficients of CH335Cl

    NASA Astrophysics Data System (ADS)

    Guinet, M.; Rohart, F.; Buldyreva, J.; Gupta, V.; Eliet, S.; Motiyenko, R. A.; Margulès, L.; Cuisset, A.; Hindle, F.; Mouret, G.

    2012-07-01

    Room-temperature N2-broadening coefficients of methyl chloride rotational lines are measured over a large interval of quantum numbers (6≤J≤50, 0≤K≤18) by a submillimeter frequency-multiplication chain (J≤31) and a terahertz photomixing continuous-wave spectrometer (J≥31). In order to check the accuracy of both techniques, the measurements of identical lines are compared for J=31. The pressure broadening coefficients are deduced from line fits using mainly a Voigt profile model. The excellent signal-to-noise ratio of the frequency-multiplication scheme highlights some speed dependence effect on the line shape. Theoretical values of these coefficients are calculated by a semi-classical approach with exact trajectories. An intermolecular potential including atom-atom interactions is used for the first time. It is shown that, contrary to the previous theoretical predictions, the contributions of short-range forces are important for all values of the rotational quantum numbers. Additional testing of modifications required in the semi-classical formalism for a correct application of the cumulant expansion is also performed. It is stated that the use of the cumulant average on the rotational states of the perturbing molecule leads, for high J and small K values, to slightly higher line-broadening coefficients, as expected for the relatively strong interacting CH3Cl-N2 system. The excellent agreement between the theoretical and the experimental results ensures the reliability of these data.

  7. Quantized correlation coefficient for measuring reproducibility of ChIP-chip data.

    PubMed

    Peng, Shouyong; Kuroda, Mitzi I; Park, Peter J

    2010-07-27

    Chromatin immunoprecipitation followed by microarray hybridization (ChIP-chip) is used to study protein-DNA interactions and histone modifications on a genome-scale. To ensure data quality, these experiments are usually performed in replicates, and a correlation coefficient between replicates is used often to assess reproducibility. However, the correlation coefficient can be misleading because it is affected not only by the reproducibility of the signal but also by the amount of binding signal present in the data. We develop the Quantized correlation coefficient (QCC) that is much less dependent on the amount of signal. This involves discretization of data into set of quantiles (quantization), a merging procedure to group the background probes, and recalculation of the Pearson correlation coefficient. This procedure reduces the influence of the background noise on the statistic, which then properly focuses more on the reproducibility of the signal. The performance of this procedure is tested in both simulated and real ChIP-chip data. For replicates with different levels of enrichment over background and coverage, we find that QCC reflects reproducibility more accurately and is more robust than the standard Pearson or Spearman correlation coefficients. The quantization and the merging procedure can also suggest a proper quantile threshold for separating signal from background for further analysis. To measure reproducibility of ChIP-chip data correctly, a correlation coefficient that is robust to the amount of signal present should be used. QCC is one such measure. The QCC statistic can also be applied in a variety of other contexts for measuring reproducibility, including analysis of array CGH data for DNA copy number and gene expression data.

  8. Pupil Influence on the Visual Outcomes of a New-Generation Multifocal Toric Intraocular Lens With a Surface-Embedded Near Segment.

    PubMed

    Wang, Mengmeng; Corpuz, Christine Carole C; Huseynova, Tukezban; Tomita, Minoru

    2016-02-01

    To evaluate the influences of preoperative pupil parameters on the visual outcomes of a new-generation multifocal toric intraocular lens (IOL) model with a surface-embedded near segment. In this prospective study, patients with cataract had phacoemulsification and implantation of Lentis Mplus toric LU-313 30TY IOLs (Oculentis GmbH, Berlin, Germany). The visual and optical outcomes were measured and compared preoperatively and postoperatively. The correlations between preoperative pupil parameters (diameter and decentration) and 3-month postoperative visual outcomes were evaluated using the Spearman's rank-order correlation coefficient (Rs) for the nonparametric data. A total of 27 eyes (16 patients) were enrolled into the current study. Statistically significant improvements in visual and refractive performances were found after the implantation of Lentis Mplus toric LU-313 30TY IOLs (P < .05). Statistically significant correlations were present between preoperative pupil diameters and postoperative visual acuities (Rs > 0; P < .05). Patients with a larger pupil always have better postoperative visual acuities. Meanwhile, there was no statistically significant correlation between pupil decentration and visual acuities (P > .05). Lentis Mplus toric LU-313 30TY IOLs provided excellent visual and optical performances during the 3-month follow-up. The preoperative pupil size is an important parameter when this toric multifocal IOL model is contemplated for surgery. Copyright 2016, SLACK Incorporated.

  9. Correlation Between Geometric Similarity of Ice Shapes and the Resulting Aerodynamic Performance Degradation: A Preliminary Investigation Using WIND

    NASA Technical Reports Server (NTRS)

    Wright, William B.; Chung, James

    1999-01-01

    Aerodynamic performance calculations were performed using WIND on ten experimental ice shapes and the corresponding ten ice shapes predicted by LEWICE 2.0. The resulting data for lift coefficient and drag coefficient are presented. The difference in aerodynamic results between the experimental ice shapes and the LEWICE ice shapes were compared to the quantitative difference in ice shape geometry presented in an earlier report. Correlations were generated to determine the geometric features which have the most effect on performance degradation. Results show that maximum lift and stall angle can be correlated to the upper horn angle and the leading edge minimum thickness. Drag coefficient can be correlated to the upper horn angle and the frequency-weighted average of the Fourier coefficients. Pitching moment correlated with the upper horn angle and to a much lesser extent to the upper and lower horn thicknesses.

  10. Reliability and Validity of the Musculoskeletal Tumor Society Scoring System for the Upper Extremity in Japanese Patients.

    PubMed

    Uehara, Kosuke; Ogura, Koichi; Akiyama, Toru; Shinoda, Yusuke; Iwata, Shintaro; Kobayashi, Eisuke; Tanzawa, Yoshikazu; Yonemoto, Tsukasa; Kawano, Hirotaka; Kawai, Akira

    2017-09-01

    The Musculoskeletal Tumor Society (MSTS) scoring system developed in 1993 is a widely used disease-specific evaluation tool for assessment of physical function in patients with musculoskeletal tumors; however, only a few studies have confirmed its reliability and validity. The aim of this study was to validate the MSTS scoring system for the upper extremity (MSTS-UE) in Japanese patients with musculoskeletal tumors for use by others in research. Does the MSTS-UE have: (1) sufficient reliability and internal consistency; (2) adequate construct validity; and (3) reasonable criterion validity in comparison to the Toronto Extremity Salvage Score (TESS) or SF-36? Reliability was performed using test-retest analysis, and internal consistency was evaluated with Cronbach's alpha coefficient. Construct validity was evaluated using a scree plot to confirm the construct number and the Akaike information criterion network. Criterion validity was evaluated by comparing the MSTS-UE with the TESS and SF-36. The test-retest reliability with intraclass correlation coefficient (0.95; 95% CI, 0.91-0.97) was excellent, and internal consistency with Cronbach's α (0.7; 95% CI, 0.53-0.81) was acceptable. There were no ceiling and floor effects. The Akaike Information Criterion network showed that lifting ability, pain, and dexterity played central roles among the components. The MSTS-UE showed substantial correlation with the TESS scoring scale (r = 0.75; p < 0.001) and fair correlation with the SF-36 physical component summary (r = 0.37; p = 0.007). Although the MSTS-UE showed slight correlation with the SF-36 mental component summary, the emotional acceptance component of the MSTS-UE showed fair correlation (r = 0.29; p = 0.039). We can conclude that the MSTS is not an adequate measure of general health-related quality of life; however, this system was designed mainly to be a simple measure of function in a single extremity. To evaluate the mental state of patients with musculoskeletal tumors in the upper extremity, further study is needed.

  11. Confidence Intervals and "F" Tests for Intraclass Correlation Coefficients Based on Three-Way Mixed Effects Models

    ERIC Educational Resources Information Center

    Zhou, Hong; Muellerleile, Paige; Ingram, Debra; Wong, Seok P.

    2011-01-01

    Intraclass correlation coefficients (ICCs) are commonly used in behavioral measurement and psychometrics when a researcher is interested in the relationship among variables of a common class. The formulas for deriving ICCs, or generalizability coefficients, vary depending on which models are specified. This article gives the equations for…

  12. Uses and Misuses of the Correlation Coefficient.

    ERIC Educational Resources Information Center

    Onwuegbuzie, Anthony J.; Daniel, Larry G.

    The purpose of this paper is to provide an in-depth critical analysis of the use and misuse of correlation coefficients. Various analytical and interpretational misconceptions are reviewed, beginning with the egregious assumption that correlational statistics may be useful in inferring causality. Additional misconceptions, stemming from…

  13. Evaluation of icing drag coefficient correlations applied to iced propeller performance prediction

    NASA Technical Reports Server (NTRS)

    Miller, Thomas L.; Shaw, R. J.; Korkan, K. D.

    1987-01-01

    Evaluation of three empirical icing drag coefficient correlations is accomplished through application to a set of propeller icing data. The various correlations represent the best means currently available for relating drag rise to various flight and atmospheric conditions for both fixed-wing and rotating airfoils, and the work presented here ilustrates and evaluates one such application of the latter case. The origins of each of the correlations are discussed, and their apparent capabilities and limitations are summarized. These correlations have been made to be an integral part of a computer code, ICEPERF, which has been designed to calculate iced propeller performance. Comparison with experimental propeller icing data shows generally good agreement, with the quality of the predicted results seen to be directly related to the radial icing extent of each case. The code's capability to properly predict thrust coefficient, power coefficient, and propeller efficiency is shown to be strongly dependent on the choice of correlation selected, as well as upon proper specificatioon of radial icing extent.

  14. Family Reintegration Experiences of Soldiers with Mild Traumatic Brain Injury

    DTIC Science & Technology

    2014-02-26

    depression scores in the spouse. Weak within-couple correlation were indicated on the other measures. Table 3 presents the Spearman correlation matrix...separately. Table 2: Spearman Correlation Coefficients for Couples Spouse MAT Spouse Depression Spouse...Anxiety Soldier MAT -0.06 Soldier Depression -0.61 Soldier Anxiety -0.12 Table 3: Spearman Correlation Coefficients for Soldiers and

  15. Correlation tests of the engine performance parameter by using the detrended cross-correlation coefficient

    NASA Astrophysics Data System (ADS)

    Dong, Keqiang; Gao, You; Jing, Liming

    2015-02-01

    The presence of cross-correlation in complex systems has long been noted and studied in a broad range of physical applications. We here focus on an aero-engine system as an example of a complex system. By applying the detrended cross-correlation (DCCA) coefficient method to aero-engine time series, we investigate the effects of the data length and the time scale on the detrended cross-correlation coefficients ρ DCCA ( T, s). We then show, for a twin-engine aircraft, that the engine fuel flow time series derived from the left engine and the right engine exhibit much stronger cross-correlations than the engine exhaust-gas temperature series derived from the left engine and the right engine do.

  16. Prediction of Very High Reynolds Number Compressible Skin Friction

    NASA Technical Reports Server (NTRS)

    Carlson, John R.

    1998-01-01

    Flat plate skin friction calculations over a range of Mach numbers from 0.4 to 3.5 at Reynolds numbers from 16 million to 492 million using a Navier Stokes method with advanced turbulence modeling are compared with incompressible skin friction coefficient correlations. The semi-empirical correlation theories of van Driest; Cope; Winkler and Cha; and Sommer and Short T' are used to transform the predicted skin friction coefficients of solutions using two algebraic Reynolds stress turbulence models in the Navier-Stokes method PAB3D. In general, the predicted skin friction coefficients scaled well with each reference temperature theory though, overall the theory by Sommer and Short appeared to best collapse the predicted coefficients. At the lower Reynolds number 3 to 30 million, both the Girimaji and Shih, Zhu and Lumley turbulence models predicted skin-friction coefficients within 2% of the semi-empirical correlation skin friction coefficients. At the higher Reynolds numbers of 100 to 500 million, the turbulence models by Shih, Zhu and Lumley and Girimaji predicted coefficients that were 6% less and 10% greater, respectively, than the semi-empirical coefficients.

  17. A Practical Theory of Micro-Solar Power Sensor Networks

    DTIC Science & Technology

    2009-04-20

    Simulation Platform TOSSIM [LLWC03] ns-2 Matlab C++ AVRORA [TLP05] Reference Hardware Mica2 WINS, Medusa Mica Mica2, Medusa Mica2 Simulated Power Power...scale. From this raw data, we can 162 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 2 4 Correlation coefficient F re qu en cy Histogram of correlation...0.5 0.6 0.7 0.8 0.9 1 0 1 2 Correlation coefficient F re qu en cy Histogram of correlation coefficient with solar radiation measurement (Turbidity at

  18. Reliability and validity of selected measures associated with increased fall risk in females over the age of 45 years with distal radius fracture - A pilot study.

    PubMed

    Mehta, Saurabh P; MacDermid, Joy C; Richardson, Julie; MacIntyre, Norma J; Grewal, Ruby

    2015-01-01

    Clinical measurement. This study examined test-retest reliability and convergent/divergent construct validity of selected tests and measures that assess balance impairment, fear of falling (FOF), impaired physical activity (PA), and lower extremity muscle strength (LEMS) in females >45 years of age after the distal radius fracture (DRF) population. Twenty one female participants with DRF were assessed on two occasions. Timed Up and Go, Functional Reach, and One Leg Standing tests assessed balance impairment. Shortened Falls Efficacy Scale, Activity-specific Balance Confidence scale, and Fall Risk Perception Questionnaire assessed FOF. International Physical Activity Questionnaire and Rapid Assessment of Physical Activity were administered to assess PA level. Chair stand test and isometric muscle strength testing for hip and knee assessed LEMS. Intraclass correlation coefficients (ICC) examined the test-retest reliability of the measures. Pearson correlation coefficients (r) examined concurrent relationships between the measures. The results demonstrated fair to excellent test-retest reliability (ICC between 0.50 and 0.96) and low to moderate concordance between the measures (low if r ≤ 0.4; moderate if r = 0.4-0.7). The results provide preliminary estimates of test-retest reliability and convergent/divergent construct validity of selected measures associated with increased risk for falling in the females >45 years of age after DRF. Further research directions to advance knowledge regarding fall risk assessment in DRF population have been identified. Copyright © 2015 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  19. Navier-Stokes, flight, and wind tunnel flow analysis for the F/A-18 aircraft

    NASA Technical Reports Server (NTRS)

    Ghaffari, Farhad

    1994-01-01

    Computational analysis of flow over the F/A-18 aircraft is presented along with complementary data from both flight and wind tunnel experiments. The computational results are based on the three-dimensional thin-layer Navier-Stokes formulation and are obtained from an accurate surface representation of the fuselage, leading-edge extension (LEX), and the wing geometry. However, the constraints imposed by either the flow solver and/or the complexity associated with the flow-field grid generation required certain geometrical approximations to be implemented in the present numerical model. In particular, such constraints inspired the removal of the empennage and the blocking (fairing) of the inlet face. The results are computed for three different free-stream flow conditions and compared with flight test data of surface pressure coefficients, surface tuft flow, and off-surface vortical flow characteristics that included breakdown phenomena. Excellent surface pressure coefficient correlations, both in terms of magnitude and overall trend, are obtained on the forebody throughout the range of flow conditions. Reasonable pressure agreement was obtained over the LEX; the general correlation tends to improve at higher angles of attack. The surface tuft flow and the off-surface vortex flow structures compared qualitatively well with the flight test results. To evaluate the computational results, a wind tunnel investigation was conducted to determine the effects of existing configurational differences between the flight vehicle and the numerical model on aerodynamic characteristics. In most cases, the geometrical approximations made to the numerical model had very little effect on overall aerodynamic characteristics.

  20. Terahertz response of dipolar impurities in polar liquids: On anomalous dielectric absorption of protein solutions

    NASA Astrophysics Data System (ADS)

    Matyushov, Dmitry V.

    2010-02-01

    A theory of radiation absorption by dielectric mixtures is presented. The coarse-grained formulation is based on the wave-vector-dependent correlation functions of molecular dipoles of the host polar liquid and a density structure factor of the solutes. A nonlinear dependence of the dielectric absorption coefficient on the solute concentration is predicted and originates from the mutual polarization of the liquid surrounding the solutes by the collective field of the solute dipoles aligned along the radiation field. The theory is applied to terahertz absorption of hydrated saccharides and proteins. While the theory gives an excellent account of the observations for saccharides, without additional assumptions and fitting parameters, experimental absorption coefficient of protein solutions significantly exceeds theoretical calculations with dipole moment of the bare protein assigned to the solute and shows a peak against the protein concentration. A substantial polarization of protein’s hydration shell, resulting in a net dipole moment, is required to explain the disagreement between theory and experiment. When the correlation function of the total dipole moment of the protein with its hydration shell from numerical simulations is used in the analytical model, an absorption peak, qualitatively similar to that seen in experiment, is obtained. The existence and position of the peak are sensitive to the specifics of the protein-protein interactions. Numerical testing of the theory requires the combination of dielectric and small-angle scattering measurements. The calculations confirm that “elastic ferroelectric bag” of water shells observed in previous numerical simulations is required to explain terahertz dielectric measurements.

Top