The accuracy of burn diagnosis codes in health administrative data: A validation study.
Mason, Stephanie A; Nathens, Avery B; Byrne, James P; Fowler, Rob; Gonzalez, Alejandro; Karanicolas, Paul J; Moineddin, Rahim; Jeschke, Marc G
2017-03-01
Health administrative databases may provide rich sources of data for the study of outcomes following burn. We aimed to determine the accuracy of International Classification of Diseases diagnoses codes for burn in a population-based administrative database. Data from a regional burn center's clinical registry of patients admitted between 2006-2013 were linked to administrative databases. Burn total body surface area (TBSA), depth, mechanism, and inhalation injury were compared between the registry and administrative records. The sensitivity, specificity, and positive and negative predictive values were determined, and coding agreement was assessed with the kappa statistic. 1215 burn center patients were linked to administrative records. TBSA codes were highly sensitive and specific for ≥10 and ≥20% TBSA (89/93% sensitive and 95/97% specific), with excellent agreement (κ, 0.85/κ, 0.88). Codes were weakly sensitive (68%) in identifying ≥10% TBSA full-thickness burn, though highly specific (86%) with moderate agreement (κ, 0.46). Codes for inhalation injury had limited sensitivity (43%) but high specificity (99%) with moderate agreement (κ, 0.54). Burn mechanism had excellent coding agreement (κ, 0.84). Administrative data diagnosis codes accurately identify burn by burn size and mechanism, while identification of inhalation injury or full-thickness burns is less sensitive but highly specific. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
[Primary cervical cancer screening].
Vargas-Hernández, Víctor Manuel; Vargas-Aguilar, Víctor Manuel; Tovar-Rodríguez, José María
2015-01-01
Cervico-uterine cancer screening with cytology decrease incidence by more than 50%. The cause of this cancer is the human papilloma virus high risk, and requires a sensitive test to provide sufficient sensitivity and specificity for early detection and greater interval period when the results are negative. The test of the human papilloma virus high risk, is effective and safe because of its excellent sensitivity, negative predictive value and optimal reproducibility, especially when combined with liquid-based cytology or biomarkers with viral load, with higher sensitivity and specificity, by reducing false positives for the detection of cervical intraepithelial neoplasia grade 2 or greater injury, with excellent clinical benefits to cervical cancer screening and related infection of human papilloma virus diseases, is currently the best test for early detection infection of human papillomavirus and the risk of carcinogenesis. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.
Goodband, Emily L; Serrano, Gonçalo; Constantino-Casas, Fernando; Archer, Joy; Watson, Penny J; Williams, Tim L
2018-01-01
The objectives of this study were fourfold: technical validation of a commercial canine 1,2-o-dilauryl-rac-glycero glutaric acid-(6'-methylresorufin) ester (DGGR) lipase assay, to calculate a reference interval for DGGR lipase by the indirect a posteriori method, to establish biological validity of the assay, and to assess agreement between DGGR lipase and specific canine pancreatic lipase (Spec cPL) assays. Dogs with histologically confirmed acute pancreatitis (n=3), chronic pancreatitis (n=8) and normal pancreatic tissue (n=7) with stored (-80°C) serum samples were identified. Relevant controls were selected. Precision, reproducibility and linearity of DGGR lipase, and the effect of sample haemolysis and freezing, were assessed. Sensitivity and specificity of DGGR lipase and Spec cPL were determined. Agreement between these two parameters was calculated using Cohen's kappa coefficient (κ). The DGGR lipase assay demonstrated excellent precision, reproducibility and linearity. Sample haemolysis and storage at -80°C for 12 months did not influence the assay. DGGR lipase (>245IU/l) and Spec cPL (>400µg/l) both showed poor sensitivity but excellent specificity for acute pancreatitis, and poor to moderate sensitivity but excellent specificity for chronic pancreatitis. Substantial agreement (κ=0.679) was found between DGGR lipase and Spec cPL. The validated DGGR lipase assay had similar sensitivity and specificity for the diagnosis of acute and chronic pancreatitis to Spec cPL. DGGR lipase is a reliable alternative to Spec cPL for the diagnosis of pancreatitis.
Stein, Sherman C; Fabbri, Andrea; Servadei, Franco; Glick, Henry A
2009-02-01
A number of clinical decision aids have been introduced to limit unnecessary computed tomographic scans in patients with mild traumatic brain injury. These aids differ in the risk factors they use to recommend a scan. We compare the instruments according to their sensitivity and specificity and recommend ones based on incremental benefit of correctly classifying patients as having surgical, nonsurgical, or no intracranial lesions. We performed a secondary analysis of prospectively collected database from 7,955 patients aged 10 years or older with mild traumatic brain injury to compare sensitivity and specificity of 6 common clinical decision strategies: the Canadian CT Head Rule, the Neurotraumatology Committee of the World Federation of Neurosurgical Societies, the New Orleans, the National Emergency X-Radiography Utilization Study II (NEXUS-II), the National Institute of Clinical Excellence guideline, and the Scandinavian Neurotrauma Committee guideline. Excluded from the database were patients for whom the history of trauma was unclear, the initial Glasgow Coma Scale score was less than 14, the injury was penetrating, vital signs were unstable, or who refused diagnostic tests. Patients revisiting the emergency department within 7 days were counted only once. The percentage of scans that would have been required by applying each of the 6 aids were Canadian CT head rule (high risk only) 53%, Canadian (medium & high risk) 56%, the Neurotraumatology Committee of the World Federation of Neurosurgical Societies 56%, New Orleans 69%, NEXUS-II 56%, National Institute of Clinical Excellence 71%, and the Scandinavian 50%. The 6 decision aids' sensitivities for surgical hematomas could not be distinguished statistically (P>.05). Sensitivity was 100% (95% confidence interval [CI] 96% to 100%) for NEXUS-II, 98.1% (95% CI 93% to 100%) for National Institute of Clinical Excellence, and 99.1% (95% CI 94% to 100%) for the other 4 clinical decision instruments. Sensitivity for any intracranial lesion ranged from 95.7% (95% CI 93% to 97%) (Scandinavian) to 100% (95% CI 98% to 100%) (National Institute of Clinical Excellence). In contrast, specificities varied between 30.9% (95% CI 30% to 32%) (National Institute of Clinical Excellence) and 52.9% (95% CI 52% to 54) (Scandinavian). NEXUS-II and the Scandinavian clinical decision aids displayed the best combination of sensitivity and specificity in this patient population. However, we cannot demonstrate that the higher sensitivity of NEXUS-II for surgical hematomas is statistically significant. Therefore, choosing which of the 2 clinical decision instruments to use must be based on decisionmakers' attitudes toward risk.
WASP (Write a Scientific Paper) using Excel - 11: Test characteristics.
Grech, Victor
2018-07-01
The calculation of various test characteristics may be required as part of a data analysis exercise. This paper explains how to set up these calculations in Microsoft Excel in order to obtain sensitivity, specificity, positive and negative predictive values, diagnostic accuracy and prevalence. Copyright © 2018 Elsevier B.V. All rights reserved.
Kang, Kang; Zhang, Xiaoying; Liu, Hongtao; Wang, Zhiwei; Zhong, Jiasheng; Huang, Zhenting; Peng, Xiao; Zeng, Yan; Wang, Yuna; Yang, Yi; Luo, Jun; Gou, Deming
2012-01-01
Background MicroRNAs (miRNAs) are small, non-coding RNAs capable of postranscriptionally regulating gene expression. Accurate expression profiling is crucial for understanding the biological roles of miRNAs, and exploring them as biomarkers of diseases. Methodology/Principal Findings A novel, highly sensitive, and reliable miRNA quantification approach,termed S-Poly(T) miRNA assay, is designed. In this assay, miRNAs are subjected to polyadenylation and reverse transcription with a S-Poly(T) primer that contains a universal reverse primer, a universal Taqman probe, an oligo(dT)11 sequence and six miRNA-specific bases. Individual miRNAs are then amplified by a specific forward primer and a universal reverse primer, and the PCR products are detected by a universal Taqman probe. The S-Poly(T) assay showed a minimum of 4-fold increase in sensitivity as compared with the stem-loop or poly(A)-based methods. A remarkable specificity in discriminating among miRNAs with high sequence similarity was also obtained with this approach. Using this method, we profiled miRNAs in human pulmonary arterial smooth muscle cells (HPASMC) and identified 9 differentially expressed miRNAs associated with hypoxia treatment. Due to its outstanding sensitivity, the number of circulating miRNAs from normal human serum was significantly expanded from 368 to 518. Conclusions/Significance With excellent sensitivity, specificity, and high-throughput, the S-Poly(T) method provides a powerful tool for miRNAs quantification and identification of tissue- or disease-specific miRNA biomarkers. PMID:23152780
Noël, Audrey; Berhin, Catherine; Hoebeke, Martin; Bouchahrouf, Warda; Yunus, Sami; Bogaerts, Pierre; Glupczynski, Youri
2016-01-01
ABSTRACT Four screening assays aimed for rapid detection of carbapenemase production from Gram-negative bacterial isolates, i.e., the Neo-Rapid Carb kit (Rosco Diagnostica A/S), the Rapidec Carba NP test (bioMérieux SA), the β Carba test (Bio-Rad Laboratories N.V.), and a homemade electrochemical assay (BYG Carba test) were evaluated against a panel comprising 328 clinical isolates (Enterobacteriaceae [n = 198] and nonfermentative Gram-negative bacilli [n = 130]) with previously characterized resistance mechanisms to carbapenems. Among Enterobacteriaceae isolates, the BYG Carba test and the β Carba test showed excellent sensitivities (respectively, 100% and 97.3%) and specificities (respectively, 98.9% and 97.7%). The two other assays yielded poorer performances with sensitivity and specificity of 91.9% and 83.9% for the Rapidec Carba NP test and of 89.2% and 89.7% for the Neo-Rapid Carb kit, respectively. Among Pseudomonas spp., sensitivities and specificities ranged, respectively, from 87.3% to 92.7% and from 88.2% to 94.1%. Finally, all tests performed poorly against Acinetobacter spp., with sensitivities and specificities, respectively, ranging from 27.3% to 75.8% and from 75 to 100%. Among commercially available assays, the β Carba test appeared to be the most convenient for routine use and showed the best overall performances, especially against OXA-48-like producers. The excellent performance of the BYG Carba test against Enterobacteriaceae was confirmed (100% sensitivity and 98.9% specificity). PMID:27927915
Rumyantseva, Tatiana; Golparian, Daniel; Nilsson, Christian S; Johansson, Emma; Falk, My; Fredlund, Hans; Van Dam, Alje; Guschin, Alexander; Unemo, Magnus
2015-10-01
In this study, we performed an evaluation of the new CE-marked multiplex real-time AmpliSens N.gonorrhoeae/C.trachomatis/M.genitalium/T.vaginalis-MULTIPRIME-FRT PCR assay compared to APTIMA tests, i.e., APTIMA COMBO 2 assay, APTIMA Trichomonas vaginalis assay (FDA-approved), and two different APTIMA Mycoplasma genitalium assays (research use only; one of them only used for discrepancy analysis). Vaginal swabs (n = 209) and first-void urine (FVU) specimens from females (n = 498) and males (n = 554), consecutive attendees (n = 1261) at a dermatovenerological clinic in Sweden, were examined. The sensitivity of the AmpliSens PCR assay for detection of C. trachomatis (6.3% prevalence), M. genitalium (5.7% prevalence), N. gonorrhoeae (0.3% prevalence), and T. vaginalis (0.08% prevalence) was 97.5% (95% confidence interval (CI): 91.2-99.6%), 81.9% (95% CI: 70.7-89.7%), 100% (95% CI: 40.2-100%) and 100% (95% CI: 16.5-100%), respectively. The specificity of the AmpliSens PCR assay was 100% (95% CI: 99.6-100%) for all agents. The analytical sensitivity and specificity for N. gonorrhoeae detection was excellent, i.e., 55 international gonococcal strains detected and 135 isolates of 13 non-gonococcal Neisseria species were negative. In conclusion, the multiplex real-time AmpliSens N.gonorrhoeae/C.trachomatis/M.genitalium/T.vaginalis-MULTIPRIME-FRT PCR assay demonstrated high sensitivity and excellent specificity for the detection of C. trachomatis, N. gonorrhoeae, and T. vaginalis, and excellent specificity but suboptimal sensitivity for M. genitalium detection. © 2015 APMIS. Published by John Wiley & Sons Ltd.
Yu, Haixiang; Canoura, Juan; Guntupalli, Bhargav; Lou, Xinhui; Xiao, Yi
2017-01-01
Sensors employing split aptamers that reassemble in the presence of a target can achieve excellent specificity, but the accompanying reduction of target affinity mitigates any overall gains in sensitivity. We for the first time have developed a split aptamer that achieves enhanced target-binding affinity through cooperative binding. We have generated a split cocaine-binding aptamer that incorporates two binding domains, such that target binding at one domain greatly increases the affinity of the second domain. We experimentally demonstrate that the resulting cooperative-binding split aptamer (CBSA) exhibits higher target binding affinity and is far more responsive in terms of target-induced aptamer assembly compared to the single-domain parent split aptamer (PSA) from which it was derived. We further confirm that the target-binding affinity of our CBSA can be affected by the cooperativity of its binding domains and the intrinsic affinity of its PSA. To the best of our knowledge, CBSA-5335 has the highest cocaine affinity of any split aptamer described to date. The CBSA-based assay also demonstrates excellent performance in target detection in complex samples. Using this CBSA, we achieved specific, ultra-sensitive, one-step fluorescence detection of cocaine within fifteen minutes at concentrations as low as 50 nM in 10% saliva without signal amplification. This limit of detection meets the standards recommended by the European Union's Driving under the Influence of Drugs, Alcohol and Medicines program. Our assay also demonstrates excellent reproducibility of results, confirming that this CBSA-platform represents a robust and sensitive means for cocaine detection in actual clinical samples.
ADHD Is Highly Prevalent in Patients Seeking Treatment for Cannabis Use Disorders.
Notzon, Daniel P; Pavlicova, Martina; Glass, Andrew; Mariani, John J; Mahony, Amy L; Brooks, Daniel J; Levin, Frances R
2016-03-31
To estimate the prevalence of ADHD and determine an effective screening test for ADHD in a population-seeking treatment for cannabis use disorders. The Conners Adult ADHD Diagnostic Interview forDiagnostic and Statistical Manual of Mental Disorders, Fourth Edition(DSM-IV; CAADID) was used to generate sensitivity and specificity data for ADHD screening tests, which were then administered to 99 participants seeking treatment for cannabis use disorders to estimate ADHD prevalence. The prevalence estimated from the Wender Utah Rating Scale (WURS) was 45% (sensitivity = 0.88, sensitivity of 0.75), from the Conners Adult ADHD Rating Scale (CAARS) 34% (sensitivity = 0.80, specificity = 0.91), from the WURS + CAARS 36% (sensitivity = 0.71, specificity = 0.95), and from the Adult ADHD Self-Report Scale (ASRS) 46% (sensitivity = 0.61, specificity = 0.86). The prevalence of ADHD in adults seeking treatment for cannabis use disorders is estimated to be between 34% and 46%. The WURS paired with the CAARS provides excellent sensitivity and specificity for the diagnosis of ADHD in this population. © The Author(s) 2016.
Jääskeläinen, Anne; Kausto, Johanna; Seitsamo, Jorma; Ojajärvi, Anneli; Nygård, Clas-Håkan; Arjas, Elja; Leino-Arjas, Päivi
2016-06-01
We analyzed the work ability index (WAI) and its first item (work ability score, WAS) - and subsequent four-year changes thereof - as predictors of disability pension (DP). We linked survey responses of 5251 Finnish municipal employees, aged 44-58 years, to pension and death register data until 2009. Job content (physical, mental, or mixed) was based on observation. Baseline (1981) WAI was divided into poor (<27), moderate (28-36), and good/excellent (>37) and WAS into poor (0-5), moderate (6-7), and good/excellent (8-10). Four-year changes in these scores were classified as strong decline (
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cary,; Bruce, R; Stubben, Christopher J
The invention provides highly sensitive and specific assays for the major citrus pathogens Xylella fastidiosa and Xanthomonas axonopodis, including a field deployable multiplexed assay capable of rapidly assaying for both pathogens simultaneously. The assays are directed at particular gene targets derived from pathogenic strains that specifically cause the major citrus diseases of citrus variegated chlorosis (Xylella fastidiosa 9a5c) and citrus canker (Xanthomonas axonopodis pv citri). The citrus pathogen assays of the invention offer femtomole sensitivity, excellent linear dynamic range, and rapid and specific detection.
Lin, Xiaodong; Liu, Yaqing; Tao, Zhanhui; Gao, Jinting; Deng, Jiankang; Yin, Jinjin; Wang, Shuo
2017-08-15
Since HCV and HIV share a common transmission path, high sensitive detection of HIV and HCV gene is of significant importance to improve diagnosis accuracy and cure rate at early stage for HIV virus-infected patients. In our investigation, a novel nanozyme-based bio-barcode fluorescence amplified assay is successfully developed for simultaneous detection of HIV and HCV DNAs with excellent sensitivity in an enzyme-free and label-free condition. Here, bimetallic nanoparticles, PtAu NPs , present outstanding peroxidase-like activity and act as barcode to catalyze oxidation of nonfluorescent substrate of amplex red (AR) into fluorescent resorufin generating stable and sensitive "Turn On" fluorescent output signal, which is for the first time to be integrated with bio-barcode strategy for fluorescence detection DNA. Furthermore, the provided strategy presents excellent specificity and can distinguish single-base mismatched mutant from target DNA. What interesting is that cascaded INHIBIT-OR logic gate is integrated with biosensors for the first time to distinguish individual target DNA from each other under logic function control, which presents great application in development of rapid and intelligent detection. Copyright © 2017. Published by Elsevier B.V.
Gruver, Aaron M; Liu, Ling; Vaillancourt, Peter; Yan, Sau-Chi B; Cook, Joel D; Roseberry Baker, Jessica A; Felke, Erin M; Lacy, Megan E; Marchal, Christophe C; Szpurka, Hadrian; Holzer, Timothy R; Rhoads, Emily K; Zeng, Wei; Wortinger, Mark A; Lu, Jirong; Chow, Chi-kin; Denning, Irene J; Beuerlein, Gregory; Davies, Julian; Hanson, Jeff C; Credille, Kelly M; Wijayawardana, Sameera R; Schade, Andrew E
2014-12-01
Development of novel targeted therapies directed against hepatocyte growth factor (HGF) or its receptor (MET) necessitates the availability of quality diagnostics to facilitate their safe and effective use. Limitations of some commercially available anti-MET antibodies have prompted development of the highly sensitive and specific clone A2H2-3. Here we report its analytical properties when applied by an automated immunohistochemistry method. Excellent antibody specificity was demonstrated by immunoblot, ELISA, and IHC evaluation of characterised cell lines including NIH3T3 overexpressing the related kinase MST1R (RON). Sensitivity was confirmed by measurements of MET in cell lines or characterised tissues. IHC correlated well with FISH and quantitative RT-PCR assessments of MET (P < 0.001). Good total agreement (89%) was observed with the anti-MET antibody clone SP44 using whole-tissue sections, but poor positive agreement (21-47%) was seen in tissue microarray cores. Multiple lots displayed appropriate reproducibility (R(2) > 0.9). Prevalence of MET positivity by IHC was higher in non-squamous cell NSCLC, MET or EGFR amplified cases, and in tumours harbouring abnormalities in EGFR exon 19 or 21. The anti-MET antibody clone A2H2-3 displays excellent specificity and sensitivity. These properties make it suitable for clinical trial investigations and development as a potential companion diagnostic. © 2014 The Authors. Histopathology Published by John Wiley & Sons Ltd.
Lubina, Nóra; Schedelbeck, Ulla; Roth, Anne; Weng, Andreas Max; Geissinger, Eva; Hönig, Arnd; Hahn, Dietbert; Bley, Thorsten Alexander
2015-05-01
To compare 3.0 Tesla breast magnetic resonance imaging (MRI) with galactography for detection of benign and malignant causes of nipple discharge in patients with negative mammography and ultrasound. We prospectively evaluated 56 breasts of 50 consecutive patients with nipple discharge who had inconspicuous mammography and ultrasound, using 3.0 Tesla breast MRI with a dedicated 16-channel breast coil, and then compared the results with galactography. Histopathological diagnoses and follow-ups were used as reference standard. Lesion size estimated on MRI was compared with the size at histopathology. Sensitivity and specificity of MRI vs. galactography for detecting pathologic findings were 95.7 % vs. 85.7 % and 69.7 % vs. 33.3 %, respectively. For the supposed concrete pathology based on MRI findings, the specificity was 67.6 % and the sensitivity 77.3 % (PPV 60.7 %, NPV 82.1 %). Eight malignant lesions were detected (14.8 %). The estimated size at breast MRI showed excellent correlation with the size at histopathology (Pearson's correlation coefficient 0.95, p < 0.0001). MRI of the breast at 3.0 Tesla is an accurate imaging test and can replace galactography in the workup of nipple discharge in patients with inconspicuous mammography and ultrasound. • Breast MRI is an excellent diagnostic tool for patients with nipple discharge. • MRI of the breast reveals malignant lesions despite inconspicuous mammography and ultrasound. • MRI of the breast has greater sensitivity and specificity than galactography. • Excellent correlation of lesion size measured at MRI and histopathology was found.
Agreement and accuracy using the FIGO, ACOG and NICE cardiotocography interpretation guidelines.
Santo, Susana; Ayres-de-Campos, Diogo; Costa-Santos, Cristina; Schnettler, William; Ugwumadu, Austin; Da Graça, Luís M
2017-02-01
One of the limitations reported with cardiotocography is the modest interobserver agreement observed in tracing interpretation. This study compared agreement, reliability and accuracy of cardiotocography interpretation using the International Federation of Gynecology and Obstetrics, American College of Obstetrics and Gynecology and National Institute for Health and Care Excellence guidelines. A total of 151 tracings were evaluated by 27 clinicians from three centers where International Federation of Gynecology and Obstetrics, American College of Obstetrics and Gynecology and National Institute for Health and Care Excellence guidelines were routinely used. Interobserver agreement was evaluated using the proportions of agreement and reliability with the κ statistic. The accuracy of tracings classified as "pathological/category III" was assessed for prediction of newborn acidemia. For all measures, 95% confidence interval were calculated. Cardiotocography classifications were more distributed with International Federation of Gynecology and Obstetrics (9, 52, 39%) and National Institute for Health and Care Excellence (30, 33, 37%) than with American College of Obstetrics and Gynecology (13, 81, 6%). The category with the highest agreement was American College of Obstetrics and Gynecology category II (proportions of agreement = 0.73, 95% confidence interval 0.70-76), and the ones with the lowest agreement were American College of Obstetrics and Gynecology categories I and III. Reliability was significantly higher with International Federation of Gynecology and Obstetrics (κ = 0.37, 95% confidence interval 0.31-0.43), and National Institute for Health and Care Excellence (κ = 0.33, 95% confidence interval 0.28-0.39) than with American College of Obstetrics and Gynecology (κ = 0.15, 95% confidence interval 0.10-0.21); however, all represent only slight/fair reliability. International Federation of Gynecology and Obstetrics and National Institute for Health and Care Excellence showed a trend towards higher sensitivities in prediction of newborn acidemia (89 and 97%, respectively) than American College of Obstetrics and Gynecology (32%), but the latter achieved a significantly higher specificity (95%). With American College of Obstetrics and Gynecology guidelines there is high agreement in category II, low reliability, low sensitivity and high specificity in prediction of acidemia. With International Federation of Gynecology and Obstetrics and National Institute for Health and Care Excellence guidelines there is higher reliability, a trend towards higher sensitivity, and lower specificity in prediction of acidemia. © 2016 Nordic Federation of Societies of Obstetrics and Gynecology.
Pakarinen, Harri; Flinkkilä, Tapio; Ohtonen, Pasi; Hyvönen, Pekka; Lakovaara, Martti; Leppilahti, Juhana; Ristiniemi, Jukka
2011-11-16
This study was designed to assess the sensitivity, specificity, and interobserver reliability of the hook test and the stress test for the intraoperative diagnosis of instability of the distal tibiofibular joint following fixation of ankle fractures resulting from supination-external rotation forces. We conducted a prospective study of 140 patients with an unstable unilateral ankle fracture resulting from a supination-external rotation mechanism (Lauge-Hansen SE). After internal fixation of the malleolar fracture, a hook test and an external rotation stress test under fluoroscopy were performed independently by the lead surgeon and assisting surgeon, followed by a standardized 7.5-Nm external rotation stress test of each ankle under fluoroscopy. A positive stress test result was defined as a side-to-side difference of >2 mm in the tibiotalar or the tibiofibular clear space on mortise radiographs. The sensitivity and specificity of each test were calculated with use of the standardized 7.5-Nm external rotation stress test as a reference. Twenty-four (17%) of the 140 patients had a positive standardized 7.5-Nm external rotation stress test after internal fixation of the malleolar fracture. The hook test had a sensitivity of 0.25 (95% confidence interval, 0.12 to 0.45) and a specificity of 0.98 (95% confidence interval, 0.94 to 1.0) for the detection of the same instabilities. The external rotation stress test had a sensitivity of 0.58 (95% confidence interval, 0.39 to 0.76) and a specificity of 0.96 (95% confidence interval, 0.90 to 0.98). Both tests had excellent interobserver reliability, with 99% agreement for the hook test and 98% for the stress test. Interobserver agreement for the hook test and the clinical stress test was excellent, but the sensitivity of these tests was insufficient to adequately detect instability of the syndesmosis intraoperatively.
Nyvold, Charlotte Guldborg
2015-05-01
Hematological malignancies are a heterogeneous group of cancers with respect to both presentation and prognosis, and many subtypes are nowadays associated with aberrations that make up excellent molecular targets for the quantification of minimal residual disease. The quantitative PCR methodology is outstanding in terms of sensitivity, specificity and reproducibility and thus an excellent choice for minimal residual disease assessment. However, the methodology still has pitfalls that should be carefully considered when the technique is integrated in a clinical setting.
Penetrating Colorectal Injuries: Diagnostic Performance of Multidetector CT with Trajectography.
Dreizin, David; Boscak, Alexis R; Anstadt, Michael J; Tirada, Nikki; Chiu, William C; Munera, Felipe; Bodanapally, Uttam K; Hornick, Michael; Stein, Deborah M
2016-12-01
Purpose To determine the diagnostic performance of multidetector computed tomography (CT) with trajectography for penetrating colorectal injuries. Materials and Methods This institutional review board-approved and HIPAA-compliant study was a 6-year blinded retrospective review by two independent readers of 182 consecutive patients who preoperatively underwent 40- or 64-row multidetector CT for penetrating torso trauma below the diaphragm and had surgically confirmed findings. Colorectal perforation was present in 42 patients. Trajectory analysis with postprocessing software was used for all studies. Additional signs evaluated were rectal contrast agent leak, collections of extruded fecal material, mural defect, wall thickening, abnormal enhancement, free fluid or stranding, and free air. The quality of the colorectal contrast agent administration was recorded. Sensitivity, specificity, predictive values, areas under the receiver operating characteristic curves (AUCs), and Cohen κ were determined. Results In patients with rectal contrast agent administration (n = 151), AUCs were 0.90-0.91, which indicated excellent accuracy. Trajectory was sensitive (88%-91%). For single wounds (n = 104), sensitivity of trajectory was 96% for both readers, but was only 80% for multiple wounds (n = 47). Contrast agent leak was highly specific (96%-98%), but insensitive (42%-46%). Improved diagnostic performance was observed in patients with poor colonic distension or opacification. Accuracy remained high (AUC, 0.86-0.99) in the group without rectal contrast agent administration (n = 31). Conclusion Trajectory had excellent sensitivity, while rectal contrast agent leak was specific but insensitive. Sensitivity of trajectory was lower for multiple wounds. Accuracy remained high in patients without rectal contrast agent administration. © RSNA, 2016.
Research on optical biosensor with up-converting phosphor marker
NASA Astrophysics Data System (ADS)
Zhao, Yongkai; Zhou, Lei; Wang, Jing; Huang, Lihua; Yan, Zhongqiang; Huang, Huijie; Yang, Ruifu; Liu, Lei; Ren, Bingqiang; Wang, Xiangzhao
2006-08-01
An optical biosensor with up-converting phosphor (UCP) marker is developed for the sensitive rapid immunoassay to the specific biomolecule. UCP can emit visible light when excited by infrared light. Through detecting and analyzing the content of UCP particles on the test strip after immunoreaction, the concentration of target analyte in the sample can be obtained. The detection sensitivity to plague IgG is better than 5 ng/ml; to plague FI-Ab is better than 100 pg/ml; to plague Yersinia pestis cell is better than 3*10^(4) CFU/ml. Good linear response characteristics and an excellent correlation (R2>=0.95) have been verified by quantitative detection results. In the practical application, detection results to 167 analytic samples have an excellent consistency with those obtained by reverse hemagglutination test. The up-converting phosphor technology (UPT) based biosensor has stable, reliable, and sensitive performances. It can meet the need of various bioassay applications.
Evaluation of ID-PaGIA syphilis antibody test.
Naaber, Paul; Makoid, Ene; Aus, Anneli; Loivukene, Krista; Poder, Airi
2009-01-01
Laboratory diagnosis of syphilis is usually accomplished by serology. There are currently a large number of different commercial treponemal tests available that vary in format, sensitivity and specificity. To evaluate the ID-PaGIA Syphilis Antibody Test as an alternative to other specific treponemal tests for primary screening or confirmation of diagnosis. Serum samples from healthy adults (n = 100) were used for detection of specificity of ID-PaGIA. To evaluate sensitivity of ID-PaGIA serum samples (n = 101) from patients with confirmed or suspected syphilis were tested for syphilis antibodies with FTA-Abs IgM, ID-PaGIA, ELISA IgM and TPHA tests. No false-positive results were found with ID-PaGIA. Sensitivity of various treponemal tests was the following: FTA-Abs IgM: 95.5%, ID-PaGIA and ELISA IgM: 94%, and TPHA 75%. The positive and negative predictive values of ID-PaGIA were 100 and 89.5%, respectively. Compared with other treponemal tests ID-PaGIA has excellent sensitivity and specificity.
Detection of anti-Yta antibodies using a sensitive and specific enzyme-linked immunosorbent assay.
Geen, J; Hullin, D A; Hogg, S I
1999-01-01
A specific, sensitive and semi-quantitative enzyme-linked immunosorbent assay (ELISA) is described to detect anti-Yta antibodies in human serum. Recombinant acetylcholinesterase (AChE E.C.3.1.1.7) was employed as the coating antigen in the microtitre plate and horseradish peroxidase (HRP)-conjugated specific antibody (IgG) was used as the secondary antibody. The method developed showed excellent sensitivity, detecting a titre > 1 in 600,000 (3.5 ng/mL mouse IgG protein) for mouse monoclonal (mMAb) anti-AChE antibody. No cross-reaction was seen with other common blood group antibodies, confirming the specificity of the method. The recombinant antigen's AChE phenotype was confirmed as Yta, as no reaction was detected with anti-Ytb-positive sera. The ELISA method correlated closely with the established serological grading system used routinely in blood transfusion laboratories.
SENSOR FOR MONITORING OF PARTICULATE EMISSIONS IN DIESEL EXHAUST GASES - PHASE I
Active Spectrum, Inc., proposes a novel, low-cost soot sensor for on-board measurement of soot emissions in diesel exhaust gases. The proposed technology is differentiated from existing methods by excellent sensitivity, high specificity to carbon particulates, and robustness ...
Wiland, Homer O; Procop, Gary W; Goldblum, John R; Tuohy, Marion; Rybicki, Lisa; Patil, Deepa T
2013-06-01
Polymerase chain reaction (PCR)-based assays using stool samples are currently the most effective method of detecting Clostridium difficile. This study examines the feasibility of this assay using mucosal biopsy samples and evaluates the interobserver reproducibility in diagnosing and distinguishing ischemic colitis from C difficile colitis. Thirty-eight biopsy specimens were reviewed and classified by 3 observers into C difficile and ischemic colitis. The findings were correlated with clinical data. PCR was performed on 34 cases using BD GeneOhm C difficile assay. The histologic interobserver agreement was excellent (κ= 0.86) and the agreement between histologic and clinical diagnosis was good (κ = 0.84). All 19 ischemic colitis cases tested negative (100% specificity) and 3 of 15 cases of C difficile colitis tested positive (20% sensitivity). C difficile colitis can be reliably distinguished from ischemic colitis using histologic criteria. The C difficile PCR test on endoscopic biopsy specimens has excellent specificity but limited sensitivity.
Establishing a malaria diagnostics centre of excellence in Kisumu, Kenya.
Ohrt, Colin; Obare, Peter; Nanakorn, Ampon; Adhiambo, Christine; Awuondo, Ken; O'Meara, Wendy Prudhomme; Remich, Shon; Martin, Kurt; Cook, Earnest; Chretien, Jean-Paul; Lucas, Carmen; Osoga, Joseph; McEvoy, Peter; Owaga, Martin Lucas; Odera, James Sande; Ogutu, Bernhards
2007-06-12
Malaria microscopy, while the gold standard for malaria diagnosis, has limitations. Efficacy estimates in drug and vaccine malaria trials are very sensitive to small errors in microscopy endpoints. This fact led to the establishment of a Malaria Diagnostics Centre of Excellence in Kisumu, Kenya. The primary objective was to ensure valid clinical trial and diagnostic test evaluations. Key secondary objectives were technology transfer to host countries, establishment of partnerships, and training of clinical microscopists. A twelve-day "long" and a four-day "short" training course consisting of supervised laboratory practicals, lectures, group discussions, demonstrations, and take home assignments were developed. Well characterized slides were developed and training materials iteratively improved. Objective pre- and post-course evaluations consisted of 30 slides (19 negative, 11 positive) with a density range of 50-660 parasites/mul, a written examination (65 questions), a photographic image examination (30 images of artifacts and species specific characteristics), and a parasite counting examination. To date, 209 microscopists have participated from 11 countries. Seventy-seven experienced microscopists participated in the "long" courses, including 47 research microscopists. Sensitivity improved by a mean of 14% (CI 9-19%) from 77% baseline (CI 73-81 %), while specificity improved by a mean of 17% (CI 11-23%) from 76% (CI 70-82%) baseline. Twenty-three microscopists who had been selected for a four-day refresher course showed continued improvement with a mean final sensitivity of 95% (CI 91-98%) and specificity of 97% (CI 95-100%). Only 9% of those taking the pre-test in the "long" course achieved a 90% sensitivity and 95% specificity, which increased to 61% of those completing the "short" course. All measures of performance improved substantially across each of the five organization types and in each course offered. The data clearly illustrated that false positive and negative malaria smears are a serious problem, even with research microscopists. Training dramatically improved performance. Quality microscopy can be provided by the Centre of Excellence concept. This concept can be extended to other diagnostics of public health importance, and comprehensive disease control strategies.
Establishing a malaria diagnostics centre of excellence in Kisumu, Kenya
Ohrt, Colin; Obare, Peter; Nanakorn, Ampon; Adhiambo, Christine; Awuondo, Ken; O'Meara, Wendy Prudhomme; Remich, Shon; Martin, Kurt; Cook, Earnest; Chretien, Jean-Paul; Lucas, Carmen; Osoga, Joseph; McEvoy, Peter; Owaga, Martin Lucas; Odera, James Sande; Ogutu, Bernhards
2007-01-01
Background Malaria microscopy, while the gold standard for malaria diagnosis, has limitations. Efficacy estimates in drug and vaccine malaria trials are very sensitive to small errors in microscopy endpoints. This fact led to the establishment of a Malaria Diagnostics Centre of Excellence in Kisumu, Kenya. The primary objective was to ensure valid clinical trial and diagnostic test evaluations. Key secondary objectives were technology transfer to host countries, establishment of partnerships, and training of clinical microscopists. Case description A twelve-day "long" and a four-day "short" training course consisting of supervised laboratory practicals, lectures, group discussions, demonstrations, and take home assignments were developed. Well characterized slides were developed and training materials iteratively improved. Objective pre- and post-course evaluations consisted of 30 slides (19 negative, 11 positive) with a density range of 50–660 parasites/μl, a written examination (65 questions), a photographic image examination (30 images of artifacts and species specific characteristics), and a parasite counting examination. Discussion and Evaluation To date, 209 microscopists have participated from 11 countries. Seventy-seven experienced microscopists participated in the "long" courses, including 47 research microscopists. Sensitivity improved by a mean of 14% (CI 9–19%) from 77% baseline (CI 73–81 %), while specificity improved by a mean of 17% (CI 11–23%) from 76% (CI 70–82%) baseline. Twenty-three microscopists who had been selected for a four-day refresher course showed continued improvement with a mean final sensitivity of 95% (CI 91–98%) and specificity of 97% (CI 95–100%). Only 9% of those taking the pre-test in the "long" course achieved a 90% sensitivity and 95% specificity, which increased to 61% of those completing the "short" course. All measures of performance improved substantially across each of the five organization types and in each course offered. Conclusion The data clearly illustrated that false positive and negative malaria smears are a serious problem, even with research microscopists. Training dramatically improved performance. Quality microscopy can be provided by the Centre of Excellence concept. This concept can be extended to other diagnostics of public health importance, and comprehensive disease control strategies. PMID:17565676
Chien, Tsair-Wei; Shao, Yang; Jen, Dong-Hui
2017-10-27
Many quality-of-life studies have been conducted in healthcare settings, but few have used Microsoft Excel to incorporate Cronbach's α with dimension coefficient (DC) for describing a scale's characteristics. To present a computer module that can report a scale's validity, we manipulated datasets to verify a DC that can be used as a factor retention criterion for demonstrating its usefulness in a patient safety culture survey (PSC). Microsoft Excel Visual Basic for Applications was used to design a computer module for simulating 2000 datasets fitting the Rasch rating scale model. The datasets consisted of (i) five dual correlation coefficients (correl. = 0.3, 0.5, 0.7, 0.9, and 1.0) on two latent traits (i.e., true scores) following a normal distribution and responses to their respective 1/3 and 2/3 items in length; (ii) 20 scenarios of item lengths from 5 to 100; and (iii) 20 sample sizes from 50 to 1000. Each item containing 5-point polytomous responses was uniformly distributed in difficulty across a ± 2 logit range. Three methods (i.e., dimension interrelation ≥0.7, Horn's parallel analysis (PA) 95% confidence interval, and individual random eigenvalues) were used for determining one factor to retain. DC refers to the binary classification (1 as one factor and 0 as many factors) used for examining accuracy with the indicators sensitivity, specificity, and area under receiver operating characteristic curve (AUC). The scale's reliability and DC were simultaneously calculated for each simulative dataset. PSC real data were demonstrated with DC to interpret reports of the unit-based construct validity using the author-made MS Excel module. The DC method presented accurate sensitivity (=0.96), specificity (=0.92) with a DC criterion (≥0.70), and AUC (=0.98) that were higher than those of the two PA methods. PA combined with DC yielded good sensitivity (=0.96), specificity (=1.0) with a DC criterion (≥0.70), and AUC (=0.99). Advances in computer technology may enable healthcare users familiar with MS Excel to apply DC as a factor retention criterion for determining a scale's unidimensionality and evaluating a scale's quality.
Gold, A J; Langlois, D K; Refsal, K R
2016-11-01
Previous studies that included limited numbers of affected dogs have suggested basal cortisol concentrations ≤55 nmol/L (2 μg/dL) are sensitive, but nonspecific, for a diagnosis of hypoadrenocorticism. A detailed assessment of the diagnostic utility of basal cortisol concentrations is warranted. To evaluate the utility of basal cortisol concentrations for the diagnosis of hypoadrenocorticism in a large number of dogs, including those with and without serum electrolyte abnormalities. Five hundred and twenty-two dogs, including 163 dogs with hypoadrenocorticism, 351 dogs with nonadrenal gland illness, and 8 dogs with equivocal results. Retrospective study. Basal and post-ACTH cortisol concentrations and sodium and potassium concentrations were collected from medical records. A receiver operating characteristic (ROC) curve was constructed for basal cortisol concentrations by standard methodologies. Sensitivity, specificity, and predictive values were determined for various cut-points. The area under the ROC curve was 0.988 and was similarly excellent regardless of serum electrolyte concentrations. At the most discriminatory cut-point of 22 nmol/L (0.8 μg/dL), sensitivity and specificity were 96.9 and 95.7%, respectively. A basal cortisol concentration of ≤55 nmol/L (2 μg/dL) resulted in a sensitivity of 99.4%. Conversely, a basal cortisol concentration of ≤5.5 nmol/L (0.19 μg/dL) resulted in a specificity of 99.1%. Similar to findings in previous studies, basal cortisol concentrations >55 nmol/L (2 μg/dL) are useful in excluding a diagnosis of hypoadrenocorticism. Interestingly, excellent specificities and positive predictive values were observed at lower cut-point cortisol concentrations. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Martens, Roland M; Bechten, Arianne; Ingala, Silvia; van Schijndel, Ronald A; Machado, Vania B; de Jong, Marcus C; Sanchez, Esther; Purcell, Derk; Arrighi, Michael H; Brashear, Robert H; Wattjes, Mike P; Barkhof, Frederik
2018-03-01
Immunotherapeutic treatments targeting amyloid-β plaques in Alzheimer's disease (AD) are associated with the presence of amyloid-related imaging abnormalities with oedema or effusion (ARIA-E), whose detection and classification is crucial to evaluate subjects enrolled in clinical trials. To investigate the applicability of subtraction MRI in the ARIA-E detection using an established ARIA-E-rating scale. We included 75 AD patients receiving bapineuzumab treatment, including 29 ARIA-E cases. Five neuroradiologists rated their brain MRI-scans with and without subtraction images. The accuracy of evaluating the presence of ARIA-E, intraclass correlation coefficient (ICC) and specific agreement was calculated. Subtraction resulted in higher sensitivity (0.966) and lower specificity (0.970) than native images (0.959, 0.991, respectively). Individual rater detection was excellent. ICC scores ranged from excellent to good, except for gyral swelling (moderate). Excellent negative and good positive specific agreement among all ARIA-E imaging features was reported in both groups. Combining sulcal hyperintensity and gyral swelling significantly increased positive agreement for subtraction images. Subtraction MRI has potential as a visual aid increasing the sensitivity of ARIA-E assessment. However, in order to improve its usefulness isotropic acquisition and enhanced training are required. The ARIA-E rating scale may benefit from combining sulcal hyperintensity and swelling. • Subtraction technique can improve detection amyloid-related imaging-abnormalities with edema/effusion in Alzheimer's patients. • The value of ARIA-E detection, classification and monitoring using subtraction was assessed. • Validation of an established ARIA-E rating scale, recommendations for improvement are reported. • Complementary statistical methods were employed to measure accuracy, inter-rater-reliability and specific agreement.
Tang, Weiming; Chen, Wen; Amini, Ali; Boeras, Debi; Falconer, Jane; Kelly, Helen; Peeling, Rosanna; Varsaneux, Olivia; Tucker, Joseph D; Easterbrook, Philippa
2017-11-01
Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV) infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT) and laboratory based EIA assays in detecting antibodies to HCV. We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567). The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab) in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs) were 98% (95% CI 98-100%) and 100% (95% CI 100-100%) compared to an enzyme immunoassay (EIA) reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients) using different reference standards (EIA, nucleic acid testing, immunoblot). There were insufficient studies to undertake subanalyses based on HIV co-infection. Oral HCV Ab RDTs also had excellent sensitivity and specificity compared to blood reference tests, respectively at 94% (95% CI 93-96%) and 100% (95% CI 100-100%). Among studies that assessed individual oral RDTs, the eight studies revealed that OraQuick ADVANCE® had a slightly higher sensitivity (98%, 95% CI 97-98%) compared to the other oral brands (pooled sensitivity: 88%, 95% CI 84-92%). RDTs, including oral tests, have excellent sensitivity and specificity compared to laboratory-based methods for HCV antibody detection across a wide range of settings. Oral HCV Ab RDTs had good sensitivity and specificity compared to blood reference standards.
Wang, Kun; Fan, Daoqing; Liu, Yaqing; Wang, Erkang
2015-11-15
Simple, rapid, sensitive and specific detection of cancer cells is of great importance for early and accurate cancer diagnostics and therapy. By coupling nanotechnology and dual-aptamer target binding strategies, we developed a colorimetric assay for visually detecting cancer cells with high sensitivity and specificity. The nanotechnology including high catalytic activity of PtAuNP and magnetic separation & concentration plays a vital role on the signal amplification and improvement of detection sensitivity. The color change caused by small amount of target cancer cells (10 cells/mL) can be clearly distinguished by naked eyes. The dual-aptamer target binding strategy guarantees the detection specificity that large amount of non-cancer cells and different cancer cells (10(4) cells/mL) cannot cause obvious color change. A detection limit as low as 10 cells/mL with detection linear range from 10 to 10(5) cells/mL was reached according to the experimental detections in phosphate buffer solution as well as serum sample. The developed enzyme-free and cost effective colorimetric assay is simple and no need of instrument while still provides excellent sensitivity, specificity and repeatability, having potential application on point-of-care cancer diagnosis. Copyright © 2015 Elsevier B.V. All rights reserved.
The meaning of diagnostic test results: a spreadsheet for swift data analysis.
Maceneaney, P M; Malone, D E
2000-03-01
To design a spreadsheet program to: (a) analyse rapidly diagnostic test result data produced in local research or reported in the literature; (b) correct reported predictive values for disease prevalence in any population; (c) estimate the post-test probability of disease in individual patients. Microsoft Excel(TM)was used. Section A: a contingency (2 x 2) table was incorporated into the spreadsheet. Formulae for standard calculations [sample size, disease prevalence, sensitivity and specificity with 95% confidence intervals, predictive values and likelihood ratios (LRs)] were linked to this table. The results change automatically when the data in the true or false negative and positive cells are changed. Section B: this estimates predictive values in any population, compensating for altered disease prevalence. Sections C-F: Bayes' theorem was incorporated to generate individual post-test probabilities. The spreadsheet generates 95% confidence intervals, LRs and a table and graph of conditional probabilities once the sensitivity and specificity of the test are entered. The latter shows the expected post-test probability of disease for any pre-test probability when a test of known sensitivity and specificity is positive or negative. This spreadsheet can be used on desktop and palmtop computers. The MS Excel(TM)version can be downloaded via the Internet from the URL ftp://radiography.com/pub/Rad-data99.xls A spreadsheet is useful for contingency table data analysis and assessment of the clinical meaning of diagnostic test results. Copyright 2000 The Royal College of Radiologists.
Kim, Jeong Rye; Suh, Chong Hyun; Yoon, Hee Mang; Lee, Jin Seong; Cho, Young Ah; Jung, Ah Young
2018-03-01
To assess the diagnostic performance of shear-wave elastography for determining the severity of liver fibrosis in children and adolescents. An electronic literature search of PubMed and EMBASE was conducted. Bivariate modelling and hierarchical summary receiver-operating-characteristic modelling were performed to evaluate the diagnostic performance of shear-wave elastography. Meta-regression and subgroup analyses according to the modality of shear-wave imaging and the degree of liver fibrosis were also performed. Twelve eligible studies with 550 patients were included. Shear-wave elastography showed a summary sensitivity of 81 % (95 % CI: 71-88) and a specificity of 91 % (95 % CI: 83-96) for the prediction of significant liver fibrosis. The number of measurements of shear-wave elastography performed was a significant factor influencing study heterogeneity. Subgroup analysis revealed shear-wave elastography to have an excellent diagnostic performance according to each degree of liver fibrosis. Supersonic shear imaging (SSI) had a higher sensitivity (p<.01) and specificity (p<.01) than acoustic radiation force impulse imaging (ARFI). Shear-wave elastography is an excellent modality for the evaluation of the severity of liver fibrosis in children and adolescents. Compared with ARFI, SSI showed better diagnostic performance for prediction of significant liver fibrosis. • Shear-wave elastography is beneficial for determining liver fibrosis severity in children. • Shear-wave elastography showed summary sensitivity of 81 %, specificity of 91 %. • SSI showed better diagnostic performance than ARFI for significant liver fibrosis.
Feleke, Daniel Getacher; Tarko, Shambel; Hadush, Haftom
2017-06-06
Rapid diagnostic tests (RDTs) are alternative methods for microscopy in the diagnosis of malaria in resource limited settings. Among commercially available RDTs, CareStart™ Malaria test was found to show reliable results. This study evaluated the performance of CareStart™ Malaria Combo test kit in Northwestern Tigray in Ethiopia. Blood samples were collected from 320 malaria-suspected patients at Mayani Hospital in Northwestern Tigray from December 2015 to March 2016. All blood samples were examined using both light microscopy and CareStart™ Malaria HRP2/pLDH Combo Test kit. Statistical analyses were performed using SPSS version 20. The overall parasite positivity using light microscopy and CareStart™ RDT was 41 (12.8%) and 43 (13.4%), respectively. The sensitivity and specificity of CareStart™ RDT, regardless of species, were found to be 95.4 and 99.3%, respectively. Furthermore, the sensitivity of CareStart™ RDT for Plasmodium falciparum or mixed infection and non-falciparum malaria parasites was 94.4 and 85.0%, respectively while the specificity was found to be 98.9 and 99.7%, respectively. The agreement between the two test methods was "excellent" with a kappa value of 0.92. CareStart™ RDT has very good sensitivity and specificity for malaria diagnosis. The test kit also has an excellent agreement with light microscopy. It is therefore useful in resource-limited areas where microscopy is not available.
Maltha, Jessica; Gamboa, Dionicia; Bendezu, Jorge; Sanchez, Luis; Cnops, Lieselotte; Gillet, Philippe; Jacobs, Jan
2012-01-01
Background In the Peruvian Amazon, Plasmodium falciparum and Plasmodium vivax malaria are endemic in rural areas, where microscopy is not available. Malaria rapid diagnostic tests (RDTs) provide quick and accurate diagnosis. However, pfhrp2 gene deletions may limit the use of histidine-rich protein-2 (PfHRP2) detecting RDTs. Further, cross-reactions of P. falciparum with P. vivax-specific test lines and vice versa may impair diagnostic specificity. Methods Thirteen RDT products were evaluated on 179 prospectively collected malaria positive samples. Species diagnosis was performed by microscopy and confirmed by PCR. Pfhrp2 gene deletions were assessed by PCR. Results Sensitivity for P. falciparum diagnosis was lower for PfHRP2 compared to P. falciparum-specific Plasmodium lactate dehydrogenase (Pf-pLDH)- detecting RDTs (71.6% vs. 98.7%, p<0.001). Most (19/21) false negative PfHRP2 results were associated with pfhrp2 gene deletions (25.7% of 74 P. falciparum samples). Diagnostic sensitivity for P. vivax (101 samples) was excellent, except for two products. In 10/12 P. vivax-detecting RDT products, cross-reactions with the PfHRP2 or Pf-pLDH line occurred at a median frequency of 2.5% (range 0%–10.9%) of P. vivax samples assessed. In two RDT products, two and one P. falciparum samples respectively cross-reacted with the Pv-pLDH line. Two Pf-pLDH/pan-pLDH-detecting RDTs showed excellent sensitivity with few (1.0%) cross-reactions but showed faint Pf-pLDH lines in 24.7% and 38.9% of P. falciparum samples. Conclusion PfHRP2-detecting RDTs are not suitable in the Peruvian Amazon due to pfhrp2 gene deletions. Two Pf-pLDH-detecting RDTs performed excellently and are promising RDTs for this region although faint test lines are of concern. PMID:22952633
Maltha, Jessica; Gamboa, Dionicia; Bendezu, Jorge; Sanchez, Luis; Cnops, Lieselotte; Gillet, Philippe; Jacobs, Jan
2012-01-01
In the Peruvian Amazon, Plasmodium falciparum and Plasmodium vivax malaria are endemic in rural areas, where microscopy is not available. Malaria rapid diagnostic tests (RDTs) provide quick and accurate diagnosis. However, pfhrp2 gene deletions may limit the use of histidine-rich protein-2 (PfHRP2) detecting RDTs. Further, cross-reactions of P. falciparum with P. vivax-specific test lines and vice versa may impair diagnostic specificity. Thirteen RDT products were evaluated on 179 prospectively collected malaria positive samples. Species diagnosis was performed by microscopy and confirmed by PCR. Pfhrp2 gene deletions were assessed by PCR. Sensitivity for P. falciparum diagnosis was lower for PfHRP2 compared to P. falciparum-specific Plasmodium lactate dehydrogenase (Pf-pLDH)-detecting RDTs (71.6% vs. 98.7%, p<0.001). Most (19/21) false negative PfHRP2 results were associated with pfhrp2 gene deletions (25.7% of 74 P. falciparum samples). Diagnostic sensitivity for P. vivax (101 samples) was excellent, except for two products. In 10/12 P. vivax-detecting RDT products, cross-reactions with the PfHRP2 or Pf-pLDH line occurred at a median frequency of 2.5% (range 0%-10.9%) of P. vivax samples assessed. In two RDT products, two and one P. falciparum samples respectively cross-reacted with the Pv-pLDH line. Two Pf-pLDH/pan-pLDH-detecting RDTs showed excellent sensitivity with few (1.0%) cross-reactions but showed faint Pf-pLDH lines in 24.7% and 38.9% of P. falciparum samples. PfHRP2-detecting RDTs are not suitable in the Peruvian Amazon due to pfhrp2 gene deletions. Two Pf-pLDH-detecting RDTs performed excellently and are promising RDTs for this region although faint test lines are of concern.
Deng, Q-W; Wang, H; Sun, C-Z; Xing, F-L; Zhang, H-Q; Zuo, L; Gu, Z-T; Yan, F-L
2017-02-01
The effect of the triglyceride (TG) to high-density lipoprotein cholesterol (HDL-C) ratio (TG/HDL-C) on clinical outcomes of acute ischaemic stroke (AIS) patients is unclear. This study sought to determine whether the TG/HDL-C ratio in AIS patients is associated with worse outcomes at 3 months. Acute ischaemic stroke patients who were admitted from 2011 to 2014 were enrolled in this study. TG, total cholesterol (TC), HDL-C and low-density lipoprotein cholesterol (LDL-C) were collected on admission. Three end-points were defined according to the modified Rankin scale (mRS) score at 3 months after symptom onset (excellent outcome, mRS 0-1; good outcome, mRS 0-2; and death, mRS 6). In all, 1006 patients were included (median age 68.5 years; 58.2% male). Higher TG, non-HDL-C and TG/HDL-C were strongly associated with the three end-points after adjustments: excellent [odds ratio (OR) = 1.39, OR 1.89 and OR 2.34, respectively] and good (OR 1.48, OR 2.90 and OR 4.12) outcomes, and death (OR 0.59, OR 0.29 and OR 0.26). According to receiver operating characteristic (ROC) analysis, the best discriminating factor was a TG/HDL-C ≥ 0.87 for excellent outcomes [area under the ROC curve (AUC) 0.596; sensitivity 73.3%; specificity 42.7%] and non-death (AUC 0.674; sensitivity 67.8%; specificity 60.6%) as well as a TG/HDL-C ≥ 1.01 for a good outcome (AUC 0.652; sensitivity 61.6%; specificity 63.2%). Patients with a TG/HDL-C < 0.87 had a 2.94-fold increased risk of death (95% confidence interval 1.89-4.55) compared with patients with a TG/HDL-C ≥ 0.87. A lower TG/HDL-C was independently associated with death and worse outcome at 3 months in AIS. © 2016 EAN.
Deng, Fengyuan; Ulcickas, James R W; Simpson, Garth J
2016-11-03
Fluorescence optical rotary dispersion (F-ORD) is proposed as a novel chiral-specific and interface-specific spectroscopic method. F-ORD measurements of uniaxial assemblies are predicted to be fully electric-dipole-allowed, with corresponding increases in sensitivity to chirality relative to chiral-specific measurements in isotropic assemblies that are commonly interpreted through coupling between electric and magnetic dynamic dipoles. Observations of strong chiral sensitivity in prior single-molecule fluorescence measurements of chiral interfacial molecules are in excellent qualitative agreement with the predictions of the F-ORD mechanism and challenging to otherwise explain. F-ORD may provide methods to suppress background fluorescence in studies of biological interfaces, as the detected signal requires both polar local order and interfacial chirality. In addition, the molecular-level descriptions of the mechanisms underpinning F-ORD may also potentially apply to aid in interpreting chiral-specific Raman and surface-enhanced Raman spectroscopy measurements of uniaxially oriented assemblies, opening up opportunities for chiral-specific and interface-specific vibrational spectroscopy.
Rofes, L; Arreola, V; Mukherjee, R; Clavé, P
2014-09-01
Oropharyngeal dysphagia (OD) is an underdiagnosed digestive disorder that causes severe nutritional and respiratory complications. Our aim was to determine the accuracy of the Eating Assessment Tool (EAT-10) and the Volume-Viscosity Swallow Test (V-VST) for clinical evaluation of OD. We studied 120 patients with swallowing difficulties and 14 healthy subjects. OD was evaluated by the 10-item screening questionnaire EAT-10 and the bedside method V-VST, videofluoroscopy (VFS) being the reference standard. The V-VST is an effort test that uses boluses of different volumes and viscosities to identify clinical signs of impaired efficacy (impaired labial seal, piecemeal deglutition, and residue) and impaired safety of swallow (cough, voice changes, and oxygen desaturation ≥3%). Discriminating ability was assessed by the AUC of the ROC curve and sensitivity and specificity values. According to VFS, prevalence of OD was 87%, 75.6% with impaired efficacy and 80.9% with impaired safety of swallow including 17.6% aspirations. The EAT-10 showed a ROC AUC of 0.89 for OD with an optimal cut-off at 2 (0.89 sensitivity and 0.82 specificity). The V-VST showed 0.94 sensitivity and 0.88 specificity for OD, 0.79 sensitivity and 0.75 specificity for impaired efficacy, 0.87 sensitivity and 0.81 specificity for impaired safety, and 0.91 sensitivity and 0.28 specificity for aspirations. Clinical methods for screening (EAT-10) and assessment (V-VST) of OD offer excellent psychometric proprieties that allow adequate management of OD. Their universal application among at-risk populations will improve the identification of patients with OD at risk for malnutrition and aspiration pneumonia. © 2014 The Authors. Neurogastroenterology & Motility published by John Wiley & Sons Ltd.
Rofes, L; Arreola, V; Mukherjee, R; Clavé, P
2014-01-01
Background Oropharyngeal dysphagia (OD) is an underdiagnosed digestive disorder that causes severe nutritional and respiratory complications. Our aim was to determine the accuracy of the Eating Assessment Tool (EAT-10) and the Volume-Viscosity Swallow Test (V-VST) for clinical evaluation of OD. Methods We studied 120 patients with swallowing difficulties and 14 healthy subjects. OD was evaluated by the 10-item screening questionnaire EAT-10 and the bedside method V-VST, videofluoroscopy (VFS) being the reference standard. The V-VST is an effort test that uses boluses of different volumes and viscosities to identify clinical signs of impaired efficacy (impaired labial seal, piecemeal deglutition, and residue) and impaired safety of swallow (cough, voice changes, and oxygen desaturation ≥3%). Discriminating ability was assessed by the AUC of the ROC curve and sensitivity and specificity values. Key Results According to VFS, prevalence of OD was 87%, 75.6% with impaired efficacy and 80.9% with impaired safety of swallow including 17.6% aspirations. The EAT-10 showed a ROC AUC of 0.89 for OD with an optimal cut-off at 2 (0.89 sensitivity and 0.82 specificity). The V-VST showed 0.94 sensitivity and 0.88 specificity for OD, 0.79 sensitivity and 0.75 specificity for impaired efficacy, 0.87 sensitivity and 0.81 specificity for impaired safety, and 0.91 sensitivity and 0.28 specificity for aspirations. Conclusions & Inferences Clinical methods for screening (EAT-10) and assessment (V-VST) of OD offer excellent psychometric proprieties that allow adequate management of OD. Their universal application among at-risk populations will improve the identification of patients with OD at risk for malnutrition and aspiration pneumonia. PMID:24909661
[Diagnostic value of cardiac magnetic resonance in patients with acute viral myocarditis].
Ouyang, Haichun; Chen, Haixiong; Hu, Yunzhao; Wu, Yanxian; Li, Wensheng; Chen, Yuying; Cen, Yujian
2014-11-01
To assess the diagnostic value of cardiac magnetic resonance (CMR) in patients with acute viral myocarditis. Thirty patients with suspected acute viral myocarditis admitted in first people's hospital of Shunde from June 2011 to June 2013 were included in this prospective study. The diagnostic sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of acute viral myocarditis were evaluated by clinical diagnosis. Diagnostic value among different scan methods and Lake Louise criteria were compared. Acute viral myocarditis was diagnosed in 63.33% (19/30) patients.Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 57.89%, 72.73%, 78.57%, 50.00%, 63.33%, respectively by edema imaging (ER).Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 78.95%, 63.64%, 78.95%, 63.64%, 73.33%, respectively using global relative enhancement (gRE).Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 78.95%, 54.55%, 75.00%, 60.00%, 70.00%, respectively using late gadolinium enhancement (LGE) criteria.Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 84.21%, 81.82%, 88.89%, 75.00%, 83.33% using Lake Louise criteria. The sensitivity, specificity, PPV, NPV, and diagnostic accuracy using Lake Louise criteria were significantly higher than using ER, gRE, LGE alone(all P < 0.05).Specificity was higher using ER than using gRE and LGE (both P < 0.05). The sensitivity, NPV, and diagnostic accuracy were significantly higher using gRE than using ER (all P < 0.05) and was similar as using LGE (all P > 0.05). Cardiac magnetic resonance is an excellent imaging modality for the diagnosis of acute viral myocarditis.
Diagnosis of hydronephrosis: comparison of radionuclide scanning and sonography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malave, S.R.; Neiman, H.L.; Spies, S.M.
1980-12-01
Diagnostic sonographic and radioisotope scanning techniques have been shown to be useful in the diagnosis of obstructive uropathy. The accuracy of both methods was compared and sonography was found to provide the more accurate data (sensitivity, 90%, specificity, 98%; accuracy, 97%). Sonography provides excellent anatomic information and enables one to grade the degree of dilatation. Renal radionuclide studies were less sensitive in detecting obstruction, particularly in the presence of chronic renal disease, but offered additional information regarding relative renal blood flow, total effective renal plasma flow, and interval change in renal parenchymal function.
Wilkes, Rebecca P; Lee, Pei-Yu A; Tsai, Yun-Long; Tsai, Chuan-Fu; Chang, Hsiu-Hui; Chang, Hsiao-Fen G; Wang, Hwa-Tang T
2015-08-01
Canine parvovirus type 2 (CPV-2), including subtypes 2a, 2b and 2c, causes an acute enteric disease in both domestic and wild animals. Rapid and sensitive diagnosis aids effective disease management at points of need (PON). A commercially available, field-deployable and user-friendly system, designed with insulated isothermal PCR (iiPCR) technology, displays excellent sensitivity and specificity for nucleic acid detection. An iiPCR method was developed for on-site detection of all circulating CPV-2 strains. Limit of detection was determined using plasmid DNA. CPV-2a, 2b and 2c strains, a feline panleukopenia virus (FPV) strain, and nine canine pathogens were tested to evaluate assay specificity. Reaction sensitivity and performance were compared with an in-house real-time PCR using serial dilutions of a CPV-2b strain and 100 canine fecal clinical samples collected from 2010 to 2014, respectively. The 95% limit of detection of the iiPCR method was 13 copies of standard DNA and detection limits for CPV-2b DNA were equivalent for iiPCR and real-time PCR. The iiPCR reaction detected CPV-2a, 2b and 2c and FPV. Non-targeted pathogens were not detected. Test results of real-time PCR and iiPCR from 99 fecal samples agreed with each other, while one real-time PCR-positive sample tested negative by iiPCR. Therefore, excellent agreement (k = 0.98) with sensitivity of 98.41% and specificity of 100% in detecting CPV-2 in feces was found between the two methods. In conclusion, the iiPCR system has potential to serve as a useful tool for rapid and accurate PON, molecular detection of CPV-2. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.
Nikolopoulou, Eleni; Lorusso, Massimo; Micelli Ferrari, Luisa; Cicinelli, Maria Vittoria; Bandello, Francesco; Querques, Giuseppe; Micelli Ferrari, Tommaso
2018-01-01
Optical coherence tomography angiography (OCTA) could be a valid tool to detect choroidal neovascularization (CNV) in neovascular age-related macular degeneration (nAMD), allowing the analysis of the type, the morphology, and the extension of CNV in most of the cases. To determine the sensitivity and specificity of OCTA in detecting CNV secondary to nAMD, compared to fluorescein angiography (FA) and indocyanine green angiography (ICGA). Prospective observational study. Patients with suspected nAMD were recruited between May and December 2016. Patients underwent FA, ICGA, spectral domain OCT, and OCTA (AngioVue, Optovue, Inc.). Sensitivity and specificity of FA, with or without ICGA, were assessed and compared with OCTA. Seventy eyes of 70 consecutive patients were included: 32 eyes (45.7%) with type I CNV, 8 eyes (11.4%) with type II CNV, 4 eyes (5.7%) with type III CNV, 6 eyes (8.6%) with mixed type I and type II CNV, and 20 eyes (28.6%) with no CNV. Sensitivity of OCTA was 88% and specificity was 90%. Concordance between FA/ICGA and OCTA was very good (0,91; range 0,81-1,00). OCTA showed high sensitivity and specificity for detection of CNV. Concordance between OCTA and gold-standard dye-based techniques was excellent. OCTA may represent a first-line noninvasive method for the diagnosis of nAMD.
The diagnostic adaptive behavior scale: evaluating its diagnostic sensitivity and specificity.
Balboni, Giulia; Tassé, Marc J; Schalock, Robert L; Borthwick-Duffy, Sharon A; Spreat, Scott; Thissen, David; Widaman, Keith F; Zhang, Dalun; Navas, Patricia
2014-11-01
The Diagnostic Adaptive Behavior Scale (DABS) was constructed with items across three domains--conceptual, social, and practical adaptive skills--and normed on a representative sample of American individuals from 4 to 21 years of age. The DABS was developed to focus its assessment around the decision point for determining the presence or absence of significant limitations of adaptive behavior for the diagnosis of Intellectual Disability (ID). The purpose of this study, which was composed of 125 individuals with and 933 without an ID-related diagnosis, was to determine the ability of the DABS to correctly identify the individuals with and without ID (i.e., sensitivity and specificity). The results indicate that the DABS sensitivity coefficients ranged from 81% to 98%, specificity coefficients ranged from 89% to 91%, and that the Area Under the Receiver Operating Characteristic Curve were excellent or good. These results indicate that the DABS has very good levels of diagnostic efficiency. Copyright © 2014. Published by Elsevier Ltd.
Woo, Sungmin; Suh, Chong Hyun; Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup
2017-11-01
The purpose of this article is to systematically review and perform a meta-analysis of the diagnostic performance of CT for diagnosis of fat-poor angiomyolipoma (AML) in patients with renal masses. MEDLINE and EMBASE were systematically searched up to February 2, 2017. We included diagnostic accuracy studies that used CT for diagnosis of fat-poor AML in patients with renal masses, using pathologic examination as the reference standard. Two independent reviewers assessed the methodologic quality using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity of included studies were calculated and were pooled and plotted in a hierarchic summary ROC plot. Sensitivity analyses using several clinically relevant covariates were performed to explore heterogeneity. Fifteen studies (2258 patients) were included. Pooled sensitivity and specificity were 0.67 (95% CI, 0.48-0.81) and 0.97 (95% CI, 0.89-0.99), respectively. Substantial and considerable heterogeneity was present with regard to sensitivity and specificity (I 2 = 91.21% and 78.53%, respectively). At sensitivity analyses, the specificity estimates were comparable and consistently high across all subgroups (0.93-1.00), but sensitivity estimates showed significant variation (0.14-0.82). Studies using pixel distribution analysis (n = 3) showed substantially lower sensitivity estimates (0.14; 95% CI, 0.04-0.40) compared with the remaining 12 studies (0.81; 95% CI, 0.76-0.85). CT shows moderate sensitivity and excellent specificity for diagnosis of fat-poor AML in patients with renal masses. When methods other than pixel distribution analysis are used, better sensitivity can be achieved.
Shiino, A; Nishida, Y; Yasuda, H; Suzuki, M; Matsuda, M; Inubushi, T
2004-01-01
Background: Normal pressure hydrocephalus (NPH) is considered to be a treatable form of dementia, because cerebrospinal fluid (CSF) shunting can lessen symptoms. However, neuroimaging has failed to predict when shunting will be effective. Objective: To investigate whether 1H (proton) magnetic resonance (MR) spectroscopy could predict functional outcome in patients after shunting. Methods: Neurological state including Hasegawa's dementia scale, gait, continence, and the modified Rankin scale were evaluated in 21 patients with secondary NPH who underwent ventriculo-peritoneal shunting. Outcomes were measured postoperatively at one and 12 months and were classified as excellent, fair, or poor. MR spectra were obtained from left hemispheric white matter. Results: Significant preoperative differences in N-acetyl aspartate (NAA)/creatine (Cr) and NAA/choline (Cho) were noted between patients with excellent and poor outcome at one month (p = 0.0014 and 0.0036, respectively). Multiple regression analysis linked higher preoperative NAA/Cr ratio, gait score, and modified Rankin scale to better one month outcome. Predictive value, sensitivity, and specificity for excellent outcome following shunting were 95.2%, 100%, and 87.5%. Multiple regression analysis indicated that NAA/Cho had the best predictive value for one year outcome (p = 0.0032); predictive value, sensitivity, and specificity were 89.5%, 90.0%, and 88.9%. Conclusions: MR spectroscopy predicted long term post-shunting outcomes in patients with secondary NPH, and it would be a useful assessment tool before lumbar drainage. PMID:15258216
Yan, Juan; Hu, Chongya; Wang, Ping; Liu, Rui; Zuo, Xiaolei; Liu, Xunwei; Song, Shiping; Fan, Chunhai; He, Dannong; Sun, Gang
2014-11-26
Prostate-specific antigen (PSA) is one of the most important biomarkers for the early diagnosis and prognosis of prostate cancer. Although many efforts have been made to achieve significant progress for the detection of PSA, challenges including relative low sensitivity, complicated operation, sophisticated instruments, and high cost remain unsolved. Here, we have developed a strategy combining rolling circle amplification (RCA)-based DNA belts and magnetic bead-based enzyme-linked immunosorbent assay (ELISA) for the highly sensitive and specific detection of PSA. At first, a 96-base circular DNA template was designed and prepared for the following RCA. Single stranded DNA (ssDNA) products from RCA were used as scaffold strand for DNA origami, which was hybridized with three staple strands of DNA. The resulting DNA belts were conjugated with multiple enzymes for signal amplification and then employed to magnetic bead based ELISA for PSA detection. Through our strategy, as low as 50 aM of PSA can be detected with excellent specificity.
Ejlersen, June A; May, Ole; Mortensen, Jesper; Nielsen, Gitte L; Lauridsen, Jeppe F; Allan, Johansen
2017-11-01
Patients with normal stress perfusion have an excellent prognosis. Prospective studies on the diagnostic accuracy of stress-only scans with contemporary, independent examinations as gold standards are lacking. A total of 109 patients with typical angina and no previous coronary artery disease underwent a 2-day stress (exercise)/rest, gated, and attenuation-corrected (AC), 99m-technetium-sestamibi perfusion study, followed by invasive coronary angiography. The stress datasets were evaluated twice by four physicians with two different training levels (expert and novice): familiar and unfamiliar with AC. The two experts also made a consensus reading of the integrated stress-rest datasets. The consensus reading and quantitative data from the invasive coronary angiography were applied as reference methods. The sensitivity/specificity were 0.92-1.00/0.73-0.90 (reference: expert consensus reading), 0.93-0.96/0.63-0.82 (reference: ≥1 stenosis>70%), and 0.75-0.88/0.70-0.88 (reference: ≥1 stenosis>50%). The four readers showed a high and fairly equal sensitivity independent of their familiarity with AC. The expert familiar with AC had the highest specificity independent of the reference method. The intraobserver and interobserver agreements on the stress-only readings were good (readers without AC experience) to excellent (readers with AC experience). AC stress-only images yielded a high sensitivity independent of the training level and experience with AC of the nuclear physician, whereas the specificity correlated positively with both. Interobserver and intraobserver agreements tended to be the best for physicians with AC experience.
Development of mercury (II) ion biosensors based on mercury-specific oligonucleotide probes.
Li, Lanying; Wen, Yanli; Xu, Li; Xu, Qin; Song, Shiping; Zuo, Xiaolei; Yan, Juan; Zhang, Weijia; Liu, Gang
2016-01-15
Mercury (II) ion (Hg(2+)) contamination can be accumulated along the food chain and cause serious threat to the public health. Plenty of research effort thus has been devoted to the development of fast, sensitive and selective biosensors for monitoring Hg(2+). Thymine was demonstrated to specifically combine with Hg(2+) and form a thymine-Hg(2+)-thymine (T-Hg(2+)-T) structure, with binding constant even higher than T-A Watson-Crick pair in DNA duplex. Recently, various novel Hg(2+) biosensors have been developed based on T-rich Mercury-Specific Oligonucleotide (MSO) probes, and exhibited advanced selectivity and excellent sensitivity for Hg(2+) detection. In this review, we explained recent development of MSO-based Hg(2+) biosensors mainly in 3 groups: fluorescent biosensors, colorimetric biosensors and electrochemical biosensors. Copyright © 2015 Elsevier B.V. All rights reserved.
Validation of the Short Obsessive–Compulsive Disorder Screener (SOCS) in children and adolescents
Rodríguez-Jiménez, Tíscar; Ortiz, Ana G.; Moreno, Elena; Lázaro, Luisa; Godoy, Antonio
2015-01-01
Background The Short Obsessive–Compulsive Disorder Screener (SOCS) is recommended by the National Institute for Health and Care Excellence as a suitable and validated screening tool for 11- to 15-year olds. Despite its excellent sensitivity and specificity in detecting obsessive–compulsive disorder (OCD), it has limitations. Aims To empirically examine whether the SOCS is suitable for assessing OCD symptoms across a wide age range of children and adolescents and to provide new data about its psychometric properties. Method Participants were 94 patients (9–19 years) with OCD, and 880 healthy controls. Results The results supported the SOCS’ unidimensional factor structure and metric invariance across samples. It showed good reliability in terms of internal consistency and temporal stability. Furthermore, it had significantly high correlations with other OCD measures and an acceptable sensitivity and specificity for detecting OCD. Conclusions The SOCS is a brief screening tool suitable for detecting OCD in children and adolescents. Declaration of interest None. Copyright and usage © The Royal College of Psychiatrists 2015. This is an open access article distributed under the terms of the Creative Commons Non-Commercial, No Derivatives (CC BY-NC-ND) licence. PMID:27703719
de Oliveira, Anapolino Macedo; Fonseca, Antônio Augusto; Camargos, Marcelo Fernandes; Orzil, Lívia Maria; Laguardia-Nascimento, Mateus; Oliveira, Anna Gabriella Guimarães; Rodrigues, Jacqueline Gomes; Sales, Mariana Lázaro; de Oliveira, Tatiana Flávia Pinheiro; de Melo, Cristiano Barros
2018-07-01
Vesicular stomatitis is an infectious disease that occurs mainly in countries of the Western Hemisphere and affects cattle, swine and horses. The clinical symptoms in cattle and swine are similar to foot-and-mouth disease and include vesicular ulceration of the tongue and mouth. The disease requires a rapid and accurate differential diagnosis, aiming for immediate implementation of control measures. The objective of the present study was to develop and perform validation tests of multiplex RT-qPCR(s) for the detection of RNA from Alagoas vesiculovirus, considering the parameters of sensitivity and analytical specificity, analytical performance (repeatability and reproducibility criteria) and the uncertainty of the measurement. The threshold cycle values obtained in triplicate from each sample were evaluated by considering the variations between days, analysts and equipment in an analysis of variance aimed at determining the variances of repeatability and reproducibility. The results showed that RT-qPCRs had excellent sensitivity and specificity in the detection of RNA of the Alagoas vesiculovirus. The validation parameters showed low coefficients of variation and were equivalent to those found in other validation studies, indicating that the tests presented excellent repeatability and reproducibility. Copyright © 2018 Elsevier B.V. All rights reserved.
Peter, S; Lacher, A; Marschal, M; Hölzl, F; Buhl, M; Autenrieth, I; Kaase, M; Willmann, M
2014-07-01
Metallo-beta-lactamase (MBL) production in Pseudomonas aeruginosa is a growing issue across the globe. Fast and reliable diagnostic tools are needed for appropriate implementation of infection control measures. In this study we evaluated the performance of three commercial combined disk tests, two EDTA based in-house combined disk tests and the Carba NP test in comparison to molecular detection of MBL genes on 133 meropenem non-susceptible non-duplicate P. aeruginosa clinical isolates. The meropenem/DPA based commercial KPC + MBL-confirm ID kit (Rosco Diagnostica, Denmark) and the MASTDISCS™ ID carbapenemase (Enterobacteriaceae) detection disc set (MAST Diagnostics, UK) showed sensitivities of 31.1 % and 28.8 % and specificities of 69.3 % and 79.6 %, respectively. The total MBL confirm kit (Rosco Diagnostica, Denmark) contains imipenem/DPA and imipenem/EDTA combination disks. Evaluation of the single disk combinations revealed 84.4 % sensitivity and 81.8 % specificity for the imipenem/DPA assay and 86.7 % sensitivity and 51.1 % specificity for the imipenem/EDTA test. Applying both tests simultaneously resulted in a slightly higher sensitivity of 88.9 % but a lower specificity of 48.9 % when compared to the single tests alone. The Carba NP test showed 93.3 % sensitivity and 96.6 % specificity. All phenotypic combined disk tests lacked either sensitivity or specificity for the detection of MBL in P. aeruginosa. The Carba NP test showed excellent test properties, but suffers from drawbacks in handling and high costs. The optimal diagnostic approach needs to be chosen depending on the epidemiological situation, laboratory resources and availability of molecular confirmation tests.
Mitchell, Rebecca; Thomas, Sunethra Devika; Langlois, Neil E I
2013-10-01
Biochemical analysis of glucose and ketones in the vitreous humour obtained at post-mortem examination is representative of the levels in the blood prior to death. Elevated levels can be indicative of conditions including diabetic ketoacidosis, which can be a cause for unexpected death. A rapid screening test for such conditions can be performed during the autopsy through urinalysis using test strips (urine 'dipstick' testing). The aim of this study was to assess the utility of urinalysis testing for post-mortem detection of derangements of glucose and ketone levels. The results of vitreous biochemical analysis and urinalysis were collated from 188 forensic autopsy cases. A vitreous glucose result of above 10 mmol/L was regarded as high. When this was compared to urinalysis results it was found that any urinalysis result above negative had a sensitivity of 0.83 and a specificity of 0.93. A vitreous ketone level of above 5 mmol/L was regarded as significantly elevated; a urinalysis result above negative had a sensitivity of 1, but a specificity of 0.12. Urinalysis ('dipstick' testing) for glucose has a good sensitivity and specificity for high vitreous glucose levels, which are regarded as indicative of pathological hyperglycaemia during life. It was found that urine testing for ketones either has an excellent sensitivity with low specificity or a poor sensitivity with a good specificity; however, this finding has to be viewed in the context of uncertainty of the biochemical level of significant ketosis.
ERIC Educational Resources Information Center
Ozonoff, Sally; Cook, Ian; Coon, Hilary; Dawson, Geraldine; Joseph, Robert M.; Klin, Ami; McMahon, William M.; Minshew, Nancy; Munson, Jeffrey A.
2004-01-01
Recent structural and functional imaging work, as well as neuropathology and neuropsychology studies, provide strong empirical support for the involvement of frontal cortex in autism. The Cambridge Neuropsychological Test Automated Battery (CANTAB) is a computer-administered set of neuropsychological tests developed to examine specific components…
Advanced x-ray imaging spectrometer
NASA Technical Reports Server (NTRS)
Callas, John L. (Inventor); Soli, George A. (Inventor)
1998-01-01
An x-ray spectrometer that also provides images of an x-ray source. Coded aperture imaging techniques are used to provide high resolution images. Imaging position-sensitive x-ray sensors with good energy resolution are utilized to provide excellent spectroscopic performance. The system produces high resolution spectral images of the x-ray source which can be viewed in any one of a number of specific energy bands.
Lennon, Elizabeth M; Boyle, Tonya E; Hutchins, Rae Grace; Friedenthal, Arit; Correa, Maria T; Bissett, Sally A; Moses, Lorra S; Papich, Mark G; Birkenheuer, Adam J
2007-08-01
To determine whether basal serum or plasma cortisol concentration can be used as a screening test to rule out hypoadrenocorticism in dogs. Retrospective case-control study. 110 dogs with nonadrenal gland illnesses and 13 dogs with hypoadrenocorticism. Sensitivity and specificity of basal serum or plasma cortisol concentrations of either
Perera, Rushini S.; Ding, Xavier C.; Tully, Frank; Oliver, James; Bright, Nigel; Bell, David; Chiodini, Peter L.; Gonzalez, Iveth J.; Polley, Spencer D.
2017-01-01
Background Accurate and efficient detection of sub-microscopic malaria infections is crucial for enabling rapid treatment and interruption of transmission. Commercially available malaria LAMP kits have excellent diagnostic performance, though throughput is limited by the need to prepare samples individually. Here, we evaluate the clinical performance of a newly developed high throughput (HTP) sample processing system for use in conjunction with the Eiken malaria LAMP kit. Methods The HTP system utilised dried blood spots (DBS) and liquid whole blood (WB), with parallel sample processing of 94 samples per run. The system was evaluated using 699 samples of known infection status pre-determined by gold standard nested PCR. Results The sensitivity and specificity of WB-HTP-LAMP was 98.6% (95% CI, 95.7–100), and 99.7% (95% CI, 99.2–100); sensitivity of DBS-HTP-LAMP was 97.1% (95% CI, 93.1–100), and specificity 100% against PCR. At parasite densities greater or equal to 2 parasites/μL, WB and DBS HTP-LAMP showed 100% sensitivity and specificity against PCR. At densities less than 2 p/μL, WB-HTP-LAMP sensitivity was 88.9% (95% CI, 77.1–100) and specificity was 99.7% (95% CI, 99.2–100); sensitivity and specificity of DBS-HTP-LAMP was 77.8% (95% CI, 54.3–99.5) and 100% respectively. Conclusions The HTP-LAMP system is a highly sensitive diagnostic test, with the potential to allow large scale population screening in malaria elimination campaigns. PMID:28166235
A Label-Free Aptasensor for Ochratoxin a Detection Based on the Structure Switch of Aptamer.
Liu, Feng; Ding, Ailing; Zheng, Jiushang; Chen, Jiucun; Wang, Bin
2018-06-01
A label-free sensing platform is developed based on switching the structure of aptamer for highly sensitive and selective fluorescence detection of ochratoxin A (OTA). OTA induces the structure of aptamer, transforms into G-quadruplex and produces strong fluorescence in the presence of zinc(II)-protoporphyrin IX probe due to the specific bind to G-quadruplex. The simple method exhibits high sensitivity towards OTA with a detection limit of 0.03 nM and excellent selectivity over other mycotoxins. In addition, the successful detection of OTA in real samples represents a promising application in food safety.
MR imaging of breast implants.
Gorczyca, D P
1994-11-01
MR imaging has proved to be an excellent imaging modality in locating free silicone and evaluating an implant for rupture, with a sensitivity of approximately 94% and specificity of 97%. Silicone has a unique MR resonance frequency and long T1 and T2 relaxation times, which allows several MR sequences to provide excellent diagnostic images. The most commonly used sequences include T2-weighted, STIR, and chemical shift imaging (Figs. 3, 13, and 14). The T2-weighted and STIR sequences are often used in conjunction with chemical water suppression. The most reliable findings on MR images for detection of implant rupture include identification of the collapsed implant shell (linguine sign) and free silicone within the breast parenchyma.
Reed, S M; Howe, D K; Morrow, J K; Graves, A; Yeargan, M R; Johnson, A L; MacKay, R J; Furr, M; Saville, W J A; Williams, N M
2013-01-01
Recent work demonstrated the value of antigen-specific antibody indices (AI and C-value) to detect intrathecal antibody production against Sarcocystis neurona for antemortem diagnosis of equine protozoal myeloencephalitis (EPM). The study was conducted to assess whether the antigen-specific antibody indices can be reduced to a simple serum : cerebrospinal fluid (CSF) titer ratio to achieve accurate EPM diagnosis. Paired serum and CSF samples from 128 horses diagnosed by postmortem examination. The sample set included 44 EPM cases, 35 cervical-vertebral malformation (CVM) cases, 39 neurologic cases other than EPM or CVM, and 10 non-neurologic cases. Antibodies against S. neurona were measured in serum and CSF pairs using the SnSAG2 and SnSAG4/3 (SnSAG2, 4/3) ELISAs, and the ratio of each respective serum titer to CSF titer was determined. Likelihood ratios and diagnostic sensitivity and specificity were calculated based on serum titers, CSF titers, and serum : CSF titer ratios. Excellent diagnostic sensitivity and specificity was obtained from the SnSAG2, 4/3 serum : CSF titer ratio. Sensitivity and specificity of 93.2 and 81.1%, respectively, were achieved using a ratio cutoff of ≤100, whereas sensitivity and specificity were 86.4 and 95.9%, respectively, if a more rigorous cutoff of ≤50 was used. Antibody titers in CSF also provided good diagnostic accuracy. Serum antibody titers alone yielded much lower sensitivity and specificity. The study confirms the value of detecting intrathecal antibody production for antemortem diagnosis of EPM, and they further show that the antigen-specific antibody indices can be reduced in practice to a simple serum : CSF titer ratio. Copyright © 2013 by the American College of Veterinary Internal Medicine.
Peng, Zhiyuan; Zou, Yubo; Xu, Shiqi; Zhong, Wenbin; Yang, Wantai
2018-06-19
Employing renewable, earth-abundant, environmentally friendly, low-cost natural materials to design flexible supercapacitors (FSCs) as energy storage devices in wearable/portable electronics represents the global perspective to build sustainable and green society. Chemically stable and flexible cellulose and electroactive lignin have been employed to construct a biomass-based FSC for the first time. The FSC was assembled using lignosulfonate/single-walled carbon nanotube HNO 3 (Lig/SWCNT HNO 3 ) pressure-sensitive hydrogels as electrodes and cellulose hydrogels as an electrolyte separator. The assembled biomass-based FSC shows high specific capacitance (292 F g -1 at a current density of 0.5 A g -1 ), excellent rate capability, and an outstanding energy density of 17.1 W h kg -1 at a power density of 324 W kg -1 . Remarkably, the FSC presents outstanding electrochemical stability even suffering 1000 bending cycles. Such excellent flexibility, stability, and electrochemical performance enable the designed biomass-based FSCs as prominent candidates in applications of wearable electronic devices.
Makdissi, Michael; Davis, Gavin
2016-10-01
The objective of this study was to determine the reliability and validity of identifying clinical signs of concussion using video analysis in Australian football. Prospective cohort study. All impacts and collisions potentially resulting in a concussion were identified during 2012 and 2013 Australian Football League seasons. Consensus definitions were developed for clinical signs associated with concussion. For intra- and inter-rater reliability analysis, two experienced clinicians independently assessed 102 randomly selected videos on two occasions. Sensitivity, specificity, positive and negative predictive values were calculated based on the diagnosis provided by team medical staff. 212 incidents resulting in possible concussion were identified in 414 Australian Football League games. The intra-rater reliability of the video-based identification of signs associated with concussion was good to excellent. Inter-rater reliability was good to excellent for impact seizure, slow to get up, motor incoordination, ragdoll appearance (2 of 4 analyses), clutching at head and facial injury. Inter-rater reliability for loss of responsiveness and blank and vacant look was only fair and did not reach statistical significance. The feature with the highest sensitivity was slow to get up (87%), but this sign had a low specificity (19%). Other video signs had a high specificity but low sensitivity. Blank and vacant look (100%) and motor incoordination (81%) had the highest positive predictive value. Video analysis may be a useful adjunct to the side-line assessment of a possible concussion. Video analysis however should not replace the need for a thorough multimodal clinical assessment. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Hayashi, Masamichi; Guerrero-Preston, Rafael; Sidransky, David; Koch, Wayne M.
2015-01-01
Molecular deep surgical margin analysis has been shown to predict locoregional recurrences of head and neck squamous cell carcinoma (HNSCC). In order to improve the accuracy and versatility of the analysis, we used a highly tumor-specific methylation marker and highly sensitive detection technology to test DNA from surgical margins. Histologically cancer-negative deep surgical margin samples were prospectively collected from 82 eligible HNSCC surgeries by an imprinting procedure (n=75) and primary tissue collection (n=70). Bisulfite treated DNA from each sample was analyzed by both conventional quantitative methylation-specific polymerase chain reaction (QMSP) and QMSP by droplet digital PCR (ddQMSP) targeting PAX5 gene promoter methylation. The association between the presence of PAX5 methylation and locoregional recurrence free survival (LRFS) was evaluated. PAX5 methylation was found in 68.0% (51/75) of tumors in the imprint samples and 71.4% (50/70) in the primary tissue samples. Among cases which did not have postoperative radiation, (n=31 in imprint samples, n=29 in tissue samples), both conventional QMSP and ddQMSP revealed that PAX5 methylation positive margins was significantly associated with poor LRFS by univariate analysis. In particular, ddQMSP increased detection of the PAX5 marker from 29% to 71% in the non-radiated imprint cases. Also, PAX5 methylated imprint margins were an excellent predictor of poor LRFS (HR=3.89, 95%CI:1.19-17.52, P=0.023) by multivariate analysis. PAX5 methylation appears to be an excellent tumor-specific marker for molecular deep surgical margin analysis of HNSCC. Moreover, the ddQMSP assay displays increased sensitivity for methylation marker detection. PMID:26304463
Yoon, Hee Mang; Suh, Chong Hyun; Cho, Young Ah; Kim, Jeong Rye; Lee, Jin Seong; Jung, Ah Young; Kim, Jung Heon; Lee, Jeong-Yong; Kim, So Yeon
2018-06-01
To evaluate the diagnostic performance of reduced-dose CT for suspected appendicitis. A systematic search of the MEDLINE and EMBASE databases was carried out through to 10 January 2017. Studies evaluating the diagnostic performance of reduced-dose CT for suspected appendicitis in paediatric and adult patients were selected. Pooled summary estimates of sensitivity and specificity were calculated using hierarchical logistic regression modelling. Meta-regression was performed. Fourteen original articles with a total of 3,262 patients were included. For all studies using reduced-dose CT, the summary sensitivity was 96 % (95 % CI 93-98) with a summary specificity of 94 % (95 % CI 92-95). For the 11 studies providing a head-to-head comparison between reduced-dose CT and standard-dose CT, reduced-dose CT demonstrated a comparable summary sensitivity of 96 % (95 % CI 91-98) and specificity of 94 % (95 % CI 93-96) without any significant differences (p=.41). In meta-regression, there were no significant factors affecting the heterogeneity. The median effective radiation dose of the reduced-dose CT was 1.8 mSv (1.46-4.16 mSv), which was a 78 % reduction in effective radiation dose compared to the standard-dose CT. Reduced-dose CT shows excellent diagnostic performance for suspected appendicitis. • Reduced-dose CT shows excellent diagnostic performance for evaluating suspected appendicitis. • Reduced-dose CT has a comparable diagnostic performance to standard-dose CT. • Median effective radiation dose of reduced-dose CT was 1.8 mSv (1.46-4.16). • Reduced-dose CT achieved a 78 % dose reduction compared to standard-dose CT.
Newly available antibodies with practical applications in surgical pathology.
Chan, John K C
2013-12-01
Selected antibodies that have become available in recent years and have applications in diagnostic pathology are discussed. They include antibodies that are organ-related, provide information on cellular differentiation or histogenetic type, have predictive value in tumors, and highlight infective agents. PAX8 (paired box gene 8) is a marker expressed in the lower female genital tract, thyroid, and kidney and their tumors. Napsin A is expressed in the lung and kidney and is an alternative marker for pulmonary adenocarcinoma. Arginase A is a sensitive and specific marker for liver tumors. ERG (Ets-related gene) is an excellent marker for endothelium and vascular tumors as well as prostatic cancer (about 50% of cases). SOX10 (SRY-related HMG box) is expressed predominantly in melanocytic and Schwann cells and the corresponding tumors. DOG1 (discovered on GIST 1) is an excellent marker for gastrointestinal stromal tumor (GIST) and acinic cell carcinoma. OCT3/4 is a pan-germ cell tumor marker, except yolk sac tumor. SALL4 is positive in various types of germ cell tumors, including yolk sac tumor. MUC4 (mucin-related antigen 4) is a sensitive and specific marker for low-grade fibromyxoid sarcoma. Langerin is a specific marker for Langerhans cells and their tumors. SOX11 is a sensitive marker for mantle cell lymphoma. New generation antibodies against anaplastic lymphoma kinase (ALK) are required to reliably demonstrate ALK gene translocation in pulmonary carcinomas. Lack of expression of succinate dehydrogenase B is seen in paragangliomas of the hereditary form and in the pediatric type of GIST. Antibodies against Trepenoma pallidum can facilitate the diagnosis of syphilis, whereas those against SV40 (simian virus 40) are helpful for diagnosis of BK virus infection and progressive multifocal leukoencephalopathy.
Development of an Indirect ELISA for Serological Diagnosis of Bovine herpesvirus 5
Campos, Fabrício S.; da Rosa, Matheus C.; Finger, Paula F.; de Oliveira, Patricia D.; Conceição, Fabricio R.; Fischer, Geferson; Roehe, Paulo M.; Leite, Fábio P. L.
2016-01-01
Bovine herpesviruses 1 and 5 (BoHV-1 and BoHV-5) are economically important pathogens, associated with a variety of clinical syndromes, including respiratory and genital disease, reproductive failure and meningoencephalitis. The standard serological assay to diagnose BoHV-1 and BoHV-5 infections is the virus neutralization test (VNT), a time consuming procedure that requires manipulation of infectious virus. In the present study a highly sensitive and specific single dilution indirect ELISA was developed using recombinant glycoprotein D from BoHV-5 as antigen (rgD5ELISA). Bovine serum samples (n = 450) were screened by VNT against BoHV-5a and by rgD5ELISA. Compared with the VNT, the rgD5ELISA demonstrated accuracy of 99.8%, with 100% sensitivity, 96.7% specificity and coefficient of agreement between the tests of 0.954. The rgD5ELISA described here shows excellent agreement with the VNT and is shown to be a simple, convenient, specific and highly sensitive virus-free assay for detection of serum antibodies to BoHV-5. PMID:26866923
Behairy, Noha H.; Dorgham, Mohsen A.
2008-01-01
The aim of this study was to detect the accuracy of routine magnetic resonance imaging (MRI) done in different centres and its agreement with arthroscopy in meniscal and ligamentous injuries of the knee. We prospectively examined 70 patients ranging in age between 22 and 59 years. History taking, plain X-ray, clinical examination, routine MRI and arthroscopy were done for all patients. Sensitivity, specificity, accuracy, positive and negative predictive values, P value and kappa agreement measures were calculated. We found a sensitivity of 47 and 100%, specificity of 95 and 75% and accuracy of 73 and 78.5%, respectively, for the medial and lateral meniscus. A sensitivity of 77.8%, specificity of 100% and accuracy of 94% was noted for the anterior cruciate ligament (ACL). We found good kappa agreements (0.43 and 0.45) for both menisci and excellent agreement (0.84) for the ACL. MRI shows high accuracy and should be used as the primary diagnostic tool for selection of candidates for arthroscopy. Level of evidence: 4. PMID:18506445
Weitzel, T; Schnabel, E; Dieckmann, S; Börner, U; Schweiger, B
2007-07-01
Point-of-care (POC) tests for influenza facilitate clinical case management, and might also be helpful in the care of travellers who are at special risk for influenza infection. To evaluate influenza POC testing in travellers, a new assay, the ImmunoCard STAT! Flu A and B, was used to investigate travellers presenting with influenza-like symptoms. Influenza virus infection was diagnosed in 27 (13%) of 203 patients by influenza virus-specific PCR and viral culture. The POC test had sensitivity and specificity values of 64% and 99% for influenza A, and 67% and 100% for influenza B, respectively. Combined sensitivity and specificity were 67% and 99%, respectively, yielding positive and negative predictive values of 95%, and positive and negative likelihood ratios of 117 and 0.34, respectively. The convenient application, excellent specificity and high positive likelihood ratio of the POC test allowed rapid identification of influenza cases. However, negative test results might require confirmation by other methods because of limitations in sensitivity. Overall, influenza POC testing appeared to be a useful tool for the management of travellers with influenza-like symptoms.
Oliveira, E; Oliveira, D; Cardoso, F A; Barbosa, J R; Marcelino, A P; Dutra, T; Araujo, T; Fernandes, L; Duque, D; Rabello, A
2017-12-01
In this study, we assessed the sensitivity, specificity, and diagnostic accuracy of a previously developed direct agglutination test (DAT) using a freeze-dried antigen derived from Leishmania infantum promastigotes and composed in a prototype kit for visceral leishmaniasis (VL) diagnosis, named DAT-LPC. To evaluate DAT-LPC reproducibility, the kit was used to analyse 207 serum samples from VL patients and 80 serum samples from patients with other parasitic infections or healthy subjects in four laboratories from different public health institutions in Brazil. DAT-LPC showed sensitivity between 96·2 and 99·5% (P = 0·14), specificity ranging from 96·2 to 97·5% (P = 0·95), and diagnostic accuracy ranging from 96·5 to 99% (P = 0·34). The inter-laboratory reproducibility of qualitative results was classified as excellent (κ index: 0·94-0·97). The reproducibility of the end-titre results in relation to the reference laboratory, ranged from 31 to 85%. These results demonstrate an excellent performance of the DAT-LPC, and validate it for the diagnosis of VL that could replace the immunofluorescent antibody test as the routine diagnostic test in the Brazilian public health system.
Sensitivity and Specificity of OCT Angiography to Detect Choroidal Neovascularization.
Faridi, Ambar; Jia, Yali; Gao, Simon S; Huang, David; Bhavsar, Kavita V; Wilson, David J; Sill, Andrew; Flaxel, Christina J; Hwang, Thomas S; Lauer, Andreas K; Bailey, Steven T
2017-01-01
To determine the sensitivity and specificity of optical coherence tomography angiography (OCTA) in the detection of choroidal neovascularization (CNV) in age-related macular degeneration (AMD). Prospective case series. Prospective series of seventy-two eyes were studied, which included eyes with treatment-naive CNV due to AMD, non-neovascular AMD, and normal controls. All eyes underwent OCTA with a spectral domain (SD) OCT (Optovue, Inc.). The 3D angiogram was segmented into separate en face views including the inner retinal angiogram, outer retinal angiogram, and choriocapillaris angiogram. Detection of abnormal flow in the outer retina served as candidate CNV with OCTA. Masked graders reviewed structural OCT alone, en face OCTA alone, and en face OCTA combined with cross-sectional OCTA for the presence of CNV. The sensitivity and specificity of CNV detection compared to the gold standard of fluorescein angiography (FA) and OCT was determined for structural SD-OCT alone, en face OCTA alone, and with en face OCTA combined with cross-sectional OCTA. Of 32 eyes with CNV, both graders identified 26 true positives with en face OCTA alone, resulting in a sensitivity of 81.3%. Four of the 6 false negatives had large subretinal hemorrhage (SRH) and sensitivity improved to 94% for both graders if eyes with SRH were excluded. The addition of cross-sectional OCTA along with en face OCTA improved the sensitivity to 100% for both graders. Structural OCT alone also had a sensitivity of 100%. The specificity of en face OCTA alone was 92.5% for grader A and 97.5% for grader B. The specificity of structural OCT alone was 97.5% for grader A and 85% for grader B. Cross-sectional OCTA combined with en face OCTA had a specificity of 97.5% for grader A and 100% for grader B. Sensitivity and specificity for CNV detection with en face OCTA combined with cross-sectional OCTA approaches that of the gold standard of FA with OCT, and it is better than en face OCTA alone. Structural OCT alone has excellent sensitivity for CNV detection. False positives from structural OCT can be mitigated with the addition of flow information with OCTA.
Song, Heli; Liu, Qingyun; Xie, Yongshu
2018-02-15
As a promising low-cost solar energy conversion technique, dye-sensitized solar cells have undergone spectacular development since 1991. For practical applications, improvement of power conversion efficiency has always been one of the major research topics. Porphyrins are outstanding sensitizers endowed with strong sunlight harvesting ability in the visible region and multiple reaction sites available for functionalization. However, judicious molecular design in consideration of light-harvest, energy levels, operational dynamics, adsorption geometry and suppression of back reactions is specifically required for achieving excellent photovoltaic performance. This feature article highlights some of the recently developed porphyrin sensitizers, especially focusing on the systematic dye structure optimization approach in combination with coadsorption and cosensitization methods in pursuing higher efficiencies. Herein, we expect to provide more insights into the structure-performance correlation and molecular engineering strategies in a stepwise manner.
INSM1 is a Sensitive and Specific Marker of Neuroendocrine Differentiation in Head and Neck Tumors.
Rooper, Lisa M; Bishop, Justin A; Westra, William H
2018-05-01
The head and neck is the site of a wide and sometimes bewildering array of neuroendocrine (NE) tumors. Although recognition of NE differentiation may be necessary for appropriate tumor classification and treatment, traditional NE markers such as synaptophysin, chromogranin, and CD56 are not always sufficiently sensitive or specific to make this distinction. Insulinoma-associated protein 1 (INSM1) is a novel transcription factor that has recently demonstrated excellent sensitivity and specificity for NE differentiation in various anatomic sites, but has not yet been extensively evaluated in tumors of the head and neck. We performed INSM1 immunohistochemistry on NE tumors (n=97) and non-NE tumors (n=626) across all histologic grades and anatomic subsites of the head and neck. INSM1 was positive in all types of head and neck NE tumors evaluated here (99.0% sensitivity), including middle ear adenoma, pituitary adenoma, paraganglioma, medullary thyroid carcinoma, olfactory neuroblastoma, small cell carcinoma, large cell NE carcinoma, and sinonasal teratocarcinosarcoma. Notably, it was positive in the vast majority of high-grade NE malignancies (95.8% sensitivity). INSM1 also was negative in almost all non-NE tumors (97.6% specificity) with the highest rates of reactivity in alveolar rhabdomyosarcoma and SWI/SNF related, matrix associated, actin dependent regulator of chromatin, subfamily B, member 1 (SMARCB1)-deficient sinonasal carcinoma. These findings confirm that INSM1 may be used as a standalone first-line marker of NE differentiation for tumors of the head and neck.
A cell-surface-anchored ratiometric i-motif sensor for extracellular pH detection.
Ying, Le; Xie, Nuli; Yang, Yanjing; Yang, Xiaohai; Zhou, Qifeng; Yin, Bincheng; Huang, Jin; Wang, Kemin
2016-06-14
A FRET-based sensor is anchored on the cell surface through streptavidin-biotin interactions. Due to the excellent properties of the pH-sensitive i-motif structure, the sensor can detect extracellular pH with high sensitivity and excellent reversibility.
Shen, Wei; Gao, Zhiqiang
2015-03-15
Leveraging on the enzymatic processing of Dengue virus (DV) RNA hybridized quantum dot-capped DNA capture probes (QD-CPs), an ultrasensitive assay for the detection and serotyping of DVs is described in the report. Briefly, DV-specific DNA CPs are first capped by QDs and then conjugated to magnetic beads. In a sample solution, strands of DV RNA form heteroduplexes with the QD-CPs on the magnetic beads. The CPs together with the QDs in the heteroduplexes are subsequently cleaved off the magnetic beads by a duplex-specific nuclease (DSN), releasing the QDs to the solution, freeing the target RNA strands, and availing them for another around of hybridization with the remaining QD-CPs. After removing the magnetic beads along with unreacted (uncleaved) QD-CPs by using a permanent magnet, ultrasensitive fluorescent detection of DV is realized through the cleaved QDs. Serotyping of DV is accomplished by a judicious design of the QD-CPs. The assay combines excellent signal generation by the highly fluorescent QDs and the effortlessness of utilizing magnetic beads in the removal of the unreacted QD-CPs. The highly efficient DSN cleavage in conjunction with its excellent mismatch discrimination ability permits serotyping of DVs in one tube with excellent sensitivity and selectivity. Copyright © 2014 Elsevier B.V. All rights reserved.
[VIDAS Stallertest: clinico-biological evaluation of a new global test for respiratory allergy].
Felden, F; Croizier, A
1998-12-01
"VIDAS Stallertest" is a new screening test for breathing allergy. It allows the detection of 10 different lung specific allergens including domestic acarids (D1), pollents (G3, W6, W21, T3 and T9), pets dander (E1 and E2), moulds (M6), cockroach (16). The method is an immunoenzymatic reaction that contains a cartridge and a cone that is cover with the allergen's mixture and is automated on the VIDAS system. The results are compared to various skin tests analyzed by instantaneous reading for 102 patients. "VIDAS Stallertest" shows an excellent agreement (93%) with the allergic patients as well as with those that are not. The specificity of the new screening test is very high (91%). A comparative study between "VIDAS Stallertest" and "Phadiatop" performed on 155 consultants in allergist office shows a correlation of 93%, a sensitivity and a specificity of 91 and 95%, respectively. "VIDAS Stallertest" is a reliable method in first intention for the general practitioner who faces a putative breathing allergy. Moreover, this is an excellent biological check-up for a questionable or negative skin test.
Emerging applications of fluorescence spectroscopy in medical microbiology field.
Shahzad, Aamir; Köhler, Gottfried; Knapp, Martin; Gaubitzer, Erwin; Puchinger, Martin; Edetsberger, Michael
2009-11-26
There are many diagnostic techniques and methods available for diagnosis of medically important microorganisms like bacteria, viruses, fungi and parasites. But, almost all these techniques and methods have some limitations or inconvenience. Most of these techniques are laborious, time consuming and with chances of false positive or false negative results. It warrants the need of a diagnostic technique which can overcome these limitations and problems. At present, there is emerging trend to use Fluorescence spectroscopy as a diagnostic as well as research tool in many fields of medical sciences. Here, we will critically discuss research studies which propose that Fluorescence spectroscopy may be an excellent diagnostic as well as excellent research tool in medical microbiology field with high sensitivity and specificity.
Validation of a portable nitric oxide analyzer for screening in primary ciliary dyskinesias.
Harris, Amanda; Bhullar, Esther; Gove, Kerry; Joslin, Rhiannon; Pelling, Jennifer; Evans, Hazel J; Walker, Woolf T; Lucas, Jane S
2014-02-10
Nasal nitric oxide (nNO) levels are very low in primary ciliary dyskinesia (PCD) and it is used as a screening test. We assessed the reliability and usability of a hand-held analyser in comparison to a stationary nitric oxide (NO) analyser in 50 participants (15 healthy, 13 PCD, 22 other respiratory diseases; age 6-79 years). Nasal NO was measured using a stationary NO analyser during a breath-holding maneuver, and using a hand-held analyser during tidal breathing, sampling at 2 ml/sec or 5 ml/sec. The three methods were compared for their specificity and sensitivity as a screen for PCD, their success rate in different age groups, within subject repeatability and acceptability. Correlation between methods was assessed. Valid nNO measurements were obtained in 94% of participants using the stationary analyser, 96% using the hand-held analyser at 5 ml/sec and 76% at 2 ml/sec. The hand-held device at 5 ml/sec had excellent sensitivity and specificity as a screening test for PCD during tidal breathing (cut-off of 30 nL/min,100% sensitivity, >95% specificity). The cut-off using the stationary analyser during breath-hold was 38 nL/min (100% sensitivity, 95% specificity). The stationary and hand-held analyser (5 ml/sec) showed reasonable within-subject repeatability(% coefficient of variation = 15). The hand-held NO analyser provides a promising screening tool for PCD.
Magnetic Resonance Imaging for Patellofemoral Chondromalacia: Is There a Role for T2 Mapping?
van Eck, Carola F; Kingston, R Scott; Crues, John V; Kharrazi, F Daniel
2017-11-01
Patellofemoral pain is common, and treatment is guided by the presence and grade of chondromalacia. To evaluate and compare the sensitivity and specificity in detecting and grading chondral abnormalities of the patella between proton density fat suppression (PDFS) and T2 mapping magnetic resonance imaging (MRI). Cohort study; Level of evidence, 2. A total of 25 patients who underwent MRI of the knee with both a PDFS sequence and T2 mapping and subsequently underwent arthroscopic knee surgery were included. The cartilage surface of the patella was graded on both MRI sequences by 2 independent, blinded radiologists. Cartilage was then graded during arthroscopic surgery by a sports medicine fellowship-trained orthopaedic surgeon. Reliability, sensitivity, specificity, and accuracy were determined for both MRI methods. The findings during arthroscopic surgery were considered the gold standard. Intraobserver and interobserver agreement for both PDFS (98.5% and 89.4%, respectively) and T2 mapping (99.4% and 91.3%, respectively) MRI were excellent. For T2 mapping, the sensitivity (61%) and specificity (64%) were comparable, whereas for PDFS there was a lower sensitivity (37%) but higher specificity (81%) in identifying cartilage abnormalities. This resulted in a similar accuracy for PDFS (59%) and T2 mapping (62%). Both PDFS and T2 mapping MRI were reliable but only moderately accurate in predicting patellar chondromalacia found during knee arthroscopic surgery.
Iosca, Simona; Lumia, Domenico; Bracchi, Elena; Duka, Ejona; De Bon, Monica; Lekaj, Manjola; Uccella, Stefano; Ghezzi, Fabio; Fugazzola, Carlo
2013-01-01
This study evaluates retrospectively the accuracy and reproducibility of multislice computed tomography with colon water distension (MSCT-c) in diagnosing bowel (BE) and ureteral (UE) endometriosis. Sixty-four patients underwent MSCT-c and videolaparoscopic surgery. Two radiologists reviewed MSCT-c examinations: sensitivity and specificity were calculated, considering histological exam as reference standard. In the BE cases, the degree of bowel wall infiltration was also assessed. Sensitivity and specificity for both readers were 100% and 97.6% for BE and 72.2% and 100% for UE; the interobserver agreement was excellent. The degree of bowel wall involvement was correctly defined in 90.9% of cases. MSCT-c is an accurate and reproducible technique but-considering the age of the patients-delivers a nonnegligible radiation dose. © 2013 Elsevier Inc. All rights reserved.
Mazurek, Micah O; Lu, Frances; Symecko, Heather; Butter, Eric; Bing, Nicole M; Hundley, Rachel J; Poulsen, Marie; Kanne, Stephen M; Macklin, Eric A; Handen, Benjamin L
2017-09-01
The transition from DSM-IV to DSM-5 criteria for autism spectrum disorder (ASD) sparked considerable concern about the potential implications of these changes. This study was designed to address limitations of prior studies by prospectively examining the concordance of DSM-IV and final DSM-5 criteria on a consecutive sample of 439 children referred for autism diagnostic evaluations. Concordance and discordance were assessed using a consistent diagnostic battery. DSM-5 criteria demonstrated excellent overall specificity and good sensitivity relative to DSM-IV criteria. Sensitivity and specificity were strongest for children meeting DSM-IV criteria for autistic disorder, but poor for those meeting criteria for Asperger's disorder and pervasive developmental disorder. Higher IQ, older age, female sex, and less pronounced ASD symptoms were associated with greater discordance.
Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin
2016-01-01
Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.
Vinuesa, Víctor; Navarro, David; Poujois, Sandrine; Zaragoza, Susana; Borrás, Rafael
2016-03-01
The performance of the Abbott Real Time MTB assay for detection of Mycobacterium tuberculosis complex in respiratory specimens was evaluated using a standard culture as the reference. The overall concordance between both methods was 0.95. The assay displayed an excellent sensitivity (100% for smear-positive/92.3% for smear-negative specimens) and specificity (100%). Copyright © 2015 Elsevier Inc. All rights reserved.
Diagnosis/Classification Criteria for Behcet's Disease
Davatchi, Fereydoun
2012-01-01
Historical Background. The ISG criteria for Behcet's, created in 1990, have excellent specificity, but lack sensitivity. The International Criteria for Behcet's Disease (ICBD) was created in 2006, as replacement to ISG. The aim of this study was to compare their performance. ISG and ICBD Criteria. For ISG oral aphthosis is mandatory. The presence of any two of the following (genital aphthosis, skin lesions, eye lesions, and positive pathergy test) will diagnose/classify the patient as BD. For ICBD, vascular lesions were added, while oral aphthosis is no more mandatory. Getting 3 or more points diagnose/classify the patient as BD (genital aphthosis 2 points, eye lesions 2 points, and the remaining each one point). Performance and Comparison of ISG and ICBD. Their sensitivity, specificity, and accuracy (percent agreement), were tested in three independent cohort of patients from Far-East (China), Middle-East (Iran), and Europe (Germany). The sensitivity for ISG was respectively 65.4%, 78.1%, 83.7% and for ICBD 87%, 98.2%, and 96.5%. The specificity for ISG was 99.2%, 98.8%, 89.5% and for ICBD 94.1%, 95.6%, and 73.7%. The accuracy for ISG was 74.2%, 85.5%, 85.5% and for ICBD 88.9%, 97.3%, and 89.5%. Conclusion. ICBD has better sensitivity, and accuracy than ISG. PMID:21961081
de Menezes, Tarciana Nobre; Oliveira, Elaine Cristina Tôrres; de Sousa Fischer, Milena Abreu Tavares
2014-02-01
Self-reported information has been used as an easy and quick method to estimate the prevalence of systemic hypertension in populations. However, verification of whether self-reports of the disease are consistent with clinical diagnosis is essential for proper use of this information. This study aimed to verify the validity and concordance between self-reported and clinical diagnosis of hypertension in the elderly population of a city in northeastern Brazil. This was a cross-sectional and population-based study. The prevalence of diagnosed and self-reported hypertension and the validity and concordance between self-reported and clinical diagnosis and their distribution according to demographic and socioeconomic variables were assessed. The validity of self-reported hypertension was determined by sensitivity, specificity, and positive and negative predictive value. Overall, 795 elderly patients were evaluated (69.1% women). There was a high prevalence of hypertension among the elderly (diagnosed: 75.1%, 95% confidence interval (CI) = 71.1%-77.9%; self-reported: 59.7%, 95% CI = 56.3%-63.1%). For self-reported hypertension, sensitivity was substantial (77.1%), specificity was excellent (93.4%), positive predictive value was excellent (97.3%), and negative predictive value was moderate (57.2%). There was a moderate concordance between self-reported and clinical diagnosis of hypertension (kappa = 0.59; P < 0.001). Reasonable validity and moderate concordance of self-reported information on hypertension was observed, which reinforces the idea that this information can be used as strategy for detecting the disease prevalence in this population. However, because of nonachievement of excellence in the validity and reliability of the measured blood pressure, this information should be carefully considered for the strategic planning of health services.
Cosottini, M; Frosini, D; Pesaresi, I; Donatelli, G; Cecchi, P; Costagli, M; Biagi, L; Ceravolo, R; Bonuccelli, U; Tosetti, M
2015-03-01
Standard neuroimaging fails in defining the anatomy of the substantia nigra and has a marginal role in the diagnosis of Parkinson disease. Recently 7T MR target imaging of the substantia nigra has been useful in diagnosing Parkinson disease. We performed a comparative study to evaluate whether susceptibility-weighted angiography can diagnose Parkinson disease with a 3T scanner. Fourteen patients with Parkinson disease and 13 healthy subjects underwent MR imaging examination at 3T and 7T by using susceptibility-weighted angiography. Two expert blinded observers and 1 neuroradiology fellow evaluated the 3T and 7T images of the sample to identify substantia nigra abnormalities indicative of Parkinson disease. Diagnostic accuracy and intra- and interobserver agreement were calculated separately for 3T and 7T acquisitions. Susceptibility-weighted angiography 7T MR imaging can diagnose Parkinson disease with a mean sensitivity of 93%, specificity of 100%, and diagnostic accuracy of 96%. 3T MR imaging diagnosed Parkinson disease with a mean sensitivity of 79%, specificity of 94%, and diagnostic accuracy of 86%. Intraobserver and interobserver agreement was excellent at 7T. At 3T, intraobserver agreement was excellent for experts, and interobserver agreement ranged between good and excellent. The less expert reader obtained a diagnostic accuracy of 89% at 3T. Susceptibility-weighted angiography images obtained at 3T and 7T differentiate controls from patients with Parkinson disease with a higher diagnostic accuracy at 7T. The capability of 3T in diagnosing Parkinson disease might encourage its use in clinical practice. The use of the more accurate 7T should be supported by a dedicated cost-effectiveness study. © 2015 by American Journal of Neuroradiology.
NASA Astrophysics Data System (ADS)
Park, Seon Joo; Song, Hyun Seok; Kwon, Oh Seok; Chung, Ji Hyun; Lee, Seung Hwan; An, Ji Hyun; Ahn, Sae Ryun; Lee, Ji Eun; Yoon, Hyeonseok; Park, Tai Hyun; Jang, Jyongsik
2014-03-01
The development of molecular detection that allows rapid responses with high sensitivity and selectivity remains challenging. Herein, we demonstrate the strategy of novel bio-nanotechnology to successfully fabricate high-performance dopamine (DA) biosensor using DA Receptor-containing uniform-particle-shaped Nanovesicles-immobilized Carboxylated poly(3,4-ethylenedioxythiophene) (CPEDOT) NTs (DRNCNs). DA molecules are commonly associated with serious diseases, such as Parkinson's and Alzheimer's diseases. For the first time, nanovesicles containing a human DA receptor D1 (hDRD1) were successfully constructed from HEK-293 cells, stably expressing hDRD1. The nanovesicles containing hDRD1 as gate-potential modulator on the conducting polymer (CP) nanomaterial transistors provided high-performance responses to DA molecule owing to their uniform, monodispersive morphologies and outstanding discrimination ability. Specifically, the DRNCNs were integrated into a liquid-ion gated field-effect transistor (FET) system via immobilization and attachment processes, leading to high sensitivity and excellent selectivity toward DA in liquid state. Unprecedentedly, the minimum detectable level (MDL) from the field-induced DA responses was as low as 10 pM in real- time, which is 10 times more sensitive than that of previously reported CP based-DA biosensors. Moreover, the FET-type DRNCN biosensor had a rapid response time (<1 s) and showed excellent selectivity in human serum.
Embroidered electrochemical sensors on gauze for rapid quantification of wound biomarkers.
Liu, Xiyuan; Lillehoj, Peter B
2017-12-15
Electrochemical sensors are an attractive platform for analytical measurements due to their high sensitivity, portability and fast response time. These attributes also make electrochemical sensors well suited for wearable applications which require excellent flexibility and durability. Towards this end, we have developed a robust electrochemical sensor on gauze via a unique embroidery fabrication process for quantitative measurements of wound biomarkers. For proof of principle, this biosensor was used to detect uric acid, a biomarker for wound severity and healing, in simulated wound fluid which exhibits high specificity, good linearly from 0 to 800µM, and excellent reproducibility. Continuous sensing of uric acid was also performed using this biosensor which reveals that it can generate consistent and accurate measurements for up to 7h. Experiments to evaluate the robustness of the embroidered gauze sensor demonstrate that it offers excellent resilience against mechanical stress and deformation, making it a promising wearable platform for assessing and monitoring wound status in situ. Copyright © 2017 Elsevier B.V. All rights reserved.
Highly conductive porous Na-embedded carbon nanowalls for high-performance capacitive deionization
NASA Astrophysics Data System (ADS)
Chang, Liang; Hu, Yun Hang
2018-05-01
Highly conductive porous Na-embedded carbon nanowalls (Na@C), which were recently invented, have exhibited excellent performance for dye-sensitized solar cells and electric double-layer capacitors. In this work, Na@C was demonstrated as an excellent electrode material for capacitive deionization (CDI). In a three-electrode configuration system, the specific capacity of the Na@C electrodes can achieve 306.4 F/g at current density of 0.2 A/g in 1 M NaCl, which is higher than that (235.2 F/g) of activated carbon (AC) electrodes. Furthermore, a high electrosorption capacity of 8.75 mg g-1 in 100 mg/L NaCl was obtained with the Na@C electrodes in a batch-mode capacitive deionization cell. It exceeds the electrosorption capacity (4.08 mg g-1) of AC electrodes. The Na@C electrode also showed a promising cycle stability. The excellent performance of Na@C electrode for capacitive deionization (CDI) can be attributed to its high electrical conductivity and large accessible surface area.
Samaniego Lopez, Cecilia; Hebe Martínez, Jimena; Uhrig, María Laura; Coluccio Leskow, Federico; Spagnuolo, Carla Cecilia
2018-04-25
A novel fluorescent molecular probe is reported, which is able to detect glycoproteins, especially mucins, with high sensitivity and with a turn-on response along with a large Stokes shift (>130 nm), within the biologically active window. The probe contains an aminotricarbocyanine as the fluorescent reporter with a linked benzoboroxole as the recognition unit, which operates through a dynamic covalent reaction between the boronic hemiester residue of the receptor and cis-diols of the analyte. The superior selectivity of the probe is displayed by the labeling of mucins present in Calu-3 cells. The new benzoboroxole fluorescent derivative gathers together key properties to make it a highly rated molecular probe: specificity, excellent solubility in water, and off-on near infrared emission. This probe is expected to be an excellent tool for imaging intracellular mucin to evaluate mucus-related diseases as well as a sensing strategy towards glycosylated structures with a high potential for theranostics approaches in biological samples. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Pan, Yi; Shi, Yupeng; Chen, Junying; Wong, Chap-Mo; Zhang, Heng; Li, Mei-Jin; Li, Cheuk-Wing; Yi, Changqing
2016-12-01
In this study, a highly sensitive and selective fluorescent Zn(2+) probe which exhibited excellent biocompatibility, water solubility, and cell-membrane permeability, was facilely synthesized in a single step by grafting polyethyleneimine (PEI) with quinoline derivatives. The primary amino groups in the branched PEI can increase water solubility and cell permeability of the probe PEIQ, while quinoline derivatives can specifically recognize Zn(2+) and reduce the potential cytotoxicity of PEI. Basing on fluorescence off-on mechanism, PEIQ demonstrated excellent sensing capability towards Zn(2+) in absolute aqueous solution, where a high sensitivity with a detection limit as low as 38.1nM, and a high selectivity over competing metal ions and potential interfering amino acids, were achieved. Inspired by these results, elementary logic operations (YES, NOT and INHIBIT) have been constructed by employing PEIQ as the gate while Zn(2+) and EDTA as chemical inputs. Together with the low cytotoxicity and good cell-permeability, the practical application of PEIQ in living cell imaging was satisfactorily demonstrated, emphasizing its wide application in fundamental biology research. Copyright © 2016. Published by Elsevier B.V.
Mani, Vigneshwaran; Chikkaveeraiah, Bhaskara V.; Patel, Vyomesh; Gutkind, J. Silvio; Rusling, James F.
2009-01-01
A densely packed gold nanoparticle platform combined with a multiple-enzyme labeled detection antibody-magnetic bead bioconjugate was used as the basis for an ultrasensitive electrochemical immunosensor to detect cancer biomarkers in serum. Sensitivity was greatly amplified by synthesizing magnetic bioconjugates particles containing 7500 horseradish peroxidase (HRP) labels along with detection antibodies (Ab2) attached to activated carboxyl groups on 1 µm diameter magnetic beads. These sensors had sensitivity of 31.5 µA mL ng−1 and detection limit (DL) of 0.5 pg mL−1 for prostate specific antigen (PSA) in 10 µL of undiluted serum. This represents an ultralow mass DL of 5 fg PSA, eight fold better than a previously reported carbon nanotube (CNT) forest immunosensor featuring multiple labels on carbon nanotubes, and near or below the normal serum levels of most cancer biomarkers. Measurements of PSA in cell lysates and human serum of cancer patients gave excellent correlations with standard ELISA assays. These easily fabricated AuNP immunosensors show excellent promise for future fabrication of bioelectronic arrays. PMID:19216571
Fall risk screening protocol for older hearing clinic patients.
Criter, Robin E; Honaker, Julie A
2017-10-01
The primary purposes of this study were (1) to describe measures that may contrast audiology patients who fall from those who do not fall and (2) to evaluate the clinical performance of measures that could be easily used for fall risk screening in a mainstream audiology hearing clinic. Cross-sectional study Study sample: Thirty-six community-dwelling audiology patient participants and 27 community-dwelling non-audiology patients over 60 years of age. The Hearing Handicap Inventory for the Elderly (HHIE) most accurately identified patients with a recent fall (sensitivity: 76.0%), while the Dizziness Handicap Inventory (DHI) most accurately identified patients without a recent fall (specificity: 90.9%). A combination of measures used in a protocol-including HHIE, DHI, number of medications, and the Timed Up and Go test-resulted in good, accurate identification of patients with or without a recent history of falls (92.0% sensitivity, 100% specificity). This study reports good sensitivity and excellent specificity for identifying patients with and without a recent history of falls when measures were combined into a screening protocol. Despite previously reported barriers, effective fall risk screenings may be performed in hearing clinic settings with measures often readily accessible to audiologists.
Husain, Shahid; Kwak, Eun Jeong; Obman, Asia; Wagener, Marilyn M; Kusne, Shimon; Stout, Janet E; McCurry, Kenneth R; Singh, Nina
2004-05-01
The clinical utility of Platelia trade mark Aspergillus galactomannan antigen for the early diagnosis of invasive aspergillosis was prospectively assessed in 70 consecutive lung transplant recipients. Sera were collected twice weekly and tested for galactomannan. Invasive aspergillosis was documented in 17.1% (12/70) of the patients. Using the generalized estimating equation model, at the cutoff value of >or= 0.5, the sensitivity of the test was 30%, specificity 93% with positive and negative likelihood ratios of 4.2 and 0.75, respectively. Increasing the cutoff value to >or= 0.66 yielded a sensitivity of 30%, specificity of 95%, and positive and negative likelihood ratios of 5.5 and 0.74. A total of 14 patients had false-positive tests, including nine who had cystic fibrosis or chronic obstructive pulmonary disease. False-positive tests occurred within 3 days of transplantation in 43% (6/14) of the patients, and within 7 days in 64% (9/14). Thus, the test demonstrated excellent specificity, but a low sensitivity for the diagnosis of aspergillosis in this patient population. Patients with cystic fibrosis or chronic obstructive pulmonary disease may transiently have a positive test in the early post-transplant period.
Jaccoulet, E; Schweitzer-Chaput, A; Toussaint, B; Prognon, P; Caudron, E
2018-09-01
Compounding of monoclonal antibody (mAbs) constantly increases in hospital. Quality control (QC) of the compounded mAbs based on quantification and identification is required to prevent potential errors and fast method is needed to manage outpatient chemotherapy administration. A simple and ultra-fast (less than 30 s) method using flow injection analysis associated to least square matching method issued from the analyzer software was performed and evaluated for the routine hospital QC of three compounded mAbs: bevacizumab, infliximab and rituximab. The method was evaluated through qualitative and quantitative parameters. Preliminary analysis of the UV absorption and second derivative spectra of the mAbs allowed us to adapt analytical conditions according to the therapeutic range of the mAbs. In terms of quantitative QC, linearity, accuracy and precision were assessed as specified in ICH guidelines. Very satisfactory recovery was achieved and the RSD (%) of the intermediate precision were less than 1.1%. Qualitative analytical parameters were also evaluated in terms of specificity, sensitivity and global precision through a matrix of confusion. Results showed to be concentration and mAbs dependant and excellent (100%) specificity and sensitivity were reached within specific concentration range. Finally, routine application on "real life" samples (n = 209) from different batch of the three mAbs complied with the specifications of the quality control i.e. excellent identification (100%) and ± 15% of targeting concentration belonging to the calibration range. The successful use of the combination of second derivative spectroscopy and partial least square matching method demonstrated the interest of FIA for the ultra-fast QC of mAbs after compounding using matching method. Copyright © 2018 Elsevier B.V. All rights reserved.
Burns, Ted M.; Conaway, Mark; Sanders, Donald B.
2010-01-01
Objective: To study the concurrent and construct validity and test-retest reliability in the practice setting of an outcome measure for myasthenia gravis (MG). Methods: Eleven centers participated in the validation study of the Myasthenia Gravis Composite (MGC) scale. Patients with MG were evaluated at 2 consecutive visits. Concurrent and construct validities of the MGC were assessed by evaluating MGC scores in the context of other MG-specific outcome measures. We used numerous potential indicators of clinical improvement to assess the sensitivity and specificity of the MGC for detecting clinical improvement. Test-retest reliability was performed on patients at the University of Virginia. Results: A total of 175 patients with MG were enrolled at 11 sites from July 1, 2008, to January 31, 2009. A total of 151 patients were seen in follow-up. Total MGC scores showed excellent concurrent validity with other MG-specific scales. Analyses of sensitivities and specificities of the MGC revealed that a 3-point improvement in total MGC score was optimal for signifying clinical improvement. A 3-point improvement in the MGC also appears to represent a meaningful improvement to most patients, as indicated by improved 15-item myasthenia gravis quality of life scale (MG-QOL15) scores. The psychometric properties were no better for an individualized subscore made up of the 2 functional domains that the patient identified as most important to treat. The test-retest reliability coefficient of the MGC was 98%, with a lower 95% confidence interval of 97%, indicating excellent test-retest reliability. Conclusions: The Myasthenia Gravis Composite is a reliable and valid instrument for measuring clinical status of patients with myasthenia gravis in the practice setting and in clinical trials. PMID:20439845
Sun, Yueying; Sun, Yuanyuan; Tian, Weimin; Liu, Chenghui; Gao, Kejian; Li, Zhengping
2018-02-07
Sensitive and accurate detection of site-specific DNA methylation is of critical significance for early diagnosis of human diseases, especially cancers. Herein, for the first time we employ a novel methylation-dependent restriction endonuclease GlaI to detect site-specific DNA methylation in a highly specific and sensitive way by coupling with isothermal exponential amplification reaction (EXPAR). GlaI can only cut the methylated target site with excellent selectivity but leave the unmethylated DNA intact. Then the newly exposed end fragments of methylated DNA can trigger EXPAR for highly efficient signal amplification while the intact unmethylated DNA will not initiate EXPAR at all. As such, only the methylated DNA is quantitatively and faithfully reflected by the real-time fluorescence signal of the GlaI-EXPAR system, and the potential false positive interference from unmethylated DNA can be effectively eliminated. Therefore, by integrating the unique features of GlaI for highly specific methylation discrimination and EXPAR for rapid and powerful signal amplification, the elegant GlaI-EXPAR assay allows the direct quantification of methylated DNA with ultrahigh sensitivity and accuracy. The detection limit of methylated DNA target has been pushed down to the aM level and the whole detection process of GlaI-EXPAR can be accomplished within a short time of 2 h. More importantly, ultrahigh specificity is achieved and as low as 0.01% methylated DNA can be clearly identified in the presence of a large excess of unmethylated DNA. This GlaI-EXPAR is also demonstrated to be capable of determining site-specific DNA methylations in real genomic DNA samples. Sharing the distinct advantages of ultrahigh sensitivity, outstanding specificity and facile operation, this new GlaI-EXPAR strategy may provide a robust and reliable platform for the detection of site-specific DNA methylations with low abundances.
Raybould, T J; Crouch, C F; Acres, S D
1987-01-01
Production of diarrhea in neonatal calves by enterotoxigenic Escherichia coli depends on its ability to attach to the epithelial cells of the intestine via surface adhesins called pili or fimbriae and to secrete enterotoxins. The most important of these fimbriae are designated K99 and F41. We produced and characterized a murine monoclonal antibody specific to F41. This monoclonal antibody and a K99-specific monoclonal antibody were used to develop sensitive and specific passive hemagglutination and capture enzyme-linked immunosorbent assays (ELISAs) for detection and quantitation of F41 and K99 antigens in E. coli cultures and culture supernatants. The capture ELISA systems exhibited excellent sensitivity and specificity, whereas the passive hemagglutination systems appeared to be oversensitive. The ability of the capture ELISAs to detect K99 and F41 fimbrial antigens in fecal specimens from calves was evaluated. Fimbrial antigens were detected in six of six specimens from scouring calves but not in four of four specimens from nonscouring calves. PMID:2880866
Shimizu, Masahiro; Imai, Hideaki; Kagoshima, Kaiei; Umezawa, Eriko; Shimizu, Tsuneo; Yoshimoto, Yuhei
2013-01-01
Surface-rendered three-dimensional (3D) 1.5-T magnetic resonance (MR) imaging is useful for presurgical simulation of microvascular decompression. This study compared the sensitivity and specificity of 1.5- and 3.0-T surface-rendered 3D MR imaging for preoperative identification of the compression vessels of trigeminal neuralgia. One hundred consecutive patients underwent microvascular decompression for trigeminal neuralgia. Forty and 60 patients were evaluated by 1.5- and 3.0-T MR imaging, respectively. Three-dimensional MR images were constructed on the basis of MR imaging, angiography, and venography data and evaluated to determine the compression vessel before surgery. MR imaging findings were compared with the microsurgical findings to compare the sensitivity and specificity of 1.5- and 3.0-T MR imaging. The agreement between MR imaging and surgical findings depended on the compression vessels. For superior cerebellar artery, 1.5- and 3.0-T MR imaging had 84.4% and 82.7% sensitivity and 100% and 100% specificity, respectively. For anterior inferior cerebellar artery, 1.5- and 3.0-T MR imaging had 33.3% and 50% sensitivity and 92.9% and 95% specificity, respectively. For the petrosal vein, 1.5- and 3.0-T MR imaging had 75% and 64.3% sensitivity and 79.2% and 78.1% specificity, respectively. Complete pain relief was obtained in 36 of 40 and 55 of 60 patients undergoing 1.5- and 3.0-T MR imaging, respectively. The present study showed that both 1.5- and 3.0-T MR imaging provided high sensitivity and specificity for preoperative assessment of the compression vessels of trigeminal neuralgia. Preoperative 3D imaging provided very high quality presurgical simulation, resulting in excellent clinical outcomes. Copyright © 2013 Elsevier Inc. All rights reserved.
Wang, Zonghua; Xia, Jianfei; Song, Daimin; Zhang, Feifei; Yang, Min; Gui, Rijun; Xia, Lin; Bi, Sai; Xia, Yanzhi
2016-03-15
A versatile label-free quadruple signal amplification biosensing platform for p53 gene (target DNA) detection was proposed. The chitosan-graphene (CS-GR) modified electrode with excellent electron transfer ability could provide a large specific surface for high levels of AuNPs-DNA attachment. The large amount of AuNPs could immobilize more capture probes and enhance the electrochemical signal with the excellent electrocatalytic activity. Furthermore, with the assist of N.BstNB I (the nicking endonuclease), target DNA could be reused and more G-quadruplex-hemin DNAzyme could be formed, allowing significant signal amplification in the presence of H2O2. Such strategy can enhance the oxidation-reduction reaction of adsorbed methylene blue (MB) and efficiently improve the sensitivity of the proposed biosensor. The morphologies of materials and the stepwise biosensor were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM) and cyclic voltammetry (CV). Differential pulse voltammetry (DPV) signals of MB provided quantitative measures of the concentrations of target DNA, with a linear calibration range of 1.0 × 10(-15)-1.0 × 10(-9)M and a detection limit of 3.0 × 10(-16)M. Moreover, the resulting biosensor also exhibited good specificity, acceptable reproducibility and stability, indicating that the present strategy was promising for broad potential application in clinic assay. Copyright © 2015 Elsevier B.V. All rights reserved.
Hua, Fei; Zhang, Pingping; Zhang, Fuli; Zhao, Yong; Li, Chunfeng; Sun, Chongyun; Wang, Xiaochen; Yang, Ruifu; Wang, Chengbin; Yu, Ailian; Zhou, Lei
2015-11-26
Francisella tularensis is a potential biowarfare/bioterrorism agent and zoonotic pathogen that causes tularemia; thus, surveillance of F. tularensis and first-level emergency response using point-of-care testing (POCT) are essential. The UPT-LF POCT assay was established to quantitatively detect F. tularensis within 15 min, and the sensitivity of the assay was 10(4) CFU · mL(-1) (100 CFU/test). The linear quantitative range covered five orders of magnitude, and the coefficients of variation were less than 10%. Except Shigella dysenteriae, UPT-LF showed excellent specificity to four strains that are also potential biowarfare/bioterrorism agents and 13 food-borne pathogenic strains. Samples with pH 2-13, high ion strengths (≥ 2 mol · L(-1) solution of KCl and NaCl), high viscosities (≤ 50 mg · mL(-1) PEG20000 or ≥ 20% glycerol), and high concentrations of biomacromolecules (≥ 400 mg · mL(-1) bovine serum albumin or ≥ 80 mg · mL(-1) casein) showed little influence on the assay. For practical utilization, the tolerance limits for seven powders and eight viscera were determined, and operation errors of liquid measurement demonstrated a minor influence on the strip. Ftu-UPT-LF is a candidate POCT method because of its excellent sensitivity, specificity, and stability in complex samples, as well as low operation error.
Potter, Jeffrey; Odutola, Jennifer; Gonzales, Christian Amurrio; Ward, Michael M
2008-08-01
Questionnaires to screen for rheumatoid arthritis (RA) have been tested in groups that were primarily well educated and Caucasian. We sought to validate the RA questions of the Connective Tissue Disease Screening Questionnaire (CSQ) in ethnic minorities in an underserved community, and to test a Spanish-language version. The Spanish-language version was developed by 2 native speakers. Consecutive English-speaking or Spanish-speaking patients in a community-based rheumatology practice completed the questionnaire. Diagnoses were confirmed by medical record review. Sensitivity and specificity of the questionnaire for a diagnosis of RA were computed for each language version, using 2 groups as controls: patients with noninflammatory conditions, and participants recruited from the community. The English-language version was tested in 53 patients with RA (79% ethnic minorities; mean education level 11.3 yrs), 85 rheumatology controls with noninflammatory conditions, and 82 community controls. Using 3 positive responses as indicating a positive screening test, the sensitivity of the questionnaire was 0.77, the specificity based on rheumatology controls was 0.45, and the specificity based on community controls was 0.94. The Spanish-language version was tested in 55 patients with RA (mean education level 7.8 yrs), 149 rheumatology controls, and 88 community controls. The sensitivity of the Spanish-language version was 0.87, with specificities of 0.60 and 0.97 using the rheumatology controls and community controls, respectively. The sensitivity of the English-language version of the RA questions of the CSQ was lower in this study than in other cohorts, reflecting differences in the performance of the questions in different ethnic or socioeconomic groups. The Spanish-language version demonstrated good sensitivity, and both had excellent specificity when tested in community controls.
Wang, Xuan; Yin, Fenggui; Bi, Yuhai; Cheng, Gong; Li, Jing; Hou, Lidan; Li, Yunlong; Yang, Baozhi; Liu, Wenjun; Yang, Limin
2016-12-01
Zika virus (ZIKV) is an arbovirus that recently emerged and has expanded worldwide, causing a global threat and raising international concerns. Current molecular diagnostics, e.g., real-time PCR and reverse transcription PCR (RT-PCR), are time consuming, expensive, and can only be deployed in a laboratory instead of for field diagnostics. This study aimed to develop a one-step reverse transcription loop-mediated isothermal amplification (RT-LAMP) platform showing sensitivity, specificity, and more convenience than previous methods, being easily distributed and implemented. Specific primers were designed and screened to target the entire ZIKV genome. The analytical sensitivity and specificity of the assay were evaluated and compared with traditional PCR and quantitative real-time PCR. Three different simulated clinical sample quick preparation protocols were evaluated to establish a rapid and straightforward treatment procedure for clinical specimens in open field detection. The RT-LAMP assay for detection of ZIKV demonstrated superior specificity and sensitivity compared to traditional PCR at the optimum reaction temperature. For the ZIKV RNA standard, the limit of detection was 20 copies/test. For the simulated ZIKV clinical samples, the limit of detection was 0.02 pfu/test, which was one order of magnitude higher than RT-PCR and similar to real-time PCR. The detection limit of simulated ZIKV specimens prepared using a protease quick processing method was consistent with that of samples prepared using commercial nucleic acid extraction kits, indicating that our ZIKV detection method could be used in point-of-care testing. The RT-LAMP assay had excellent sensitivity and specificity for detecting ZIKV and can be deployed together with a rapid specimen processing method, offering the possibility for ZIKV diagnosis outside of the laboratory. Copyright © 2016 Elsevier B.V. All rights reserved.
Pediatric medical complexity algorithm: a new method to stratify children by medical complexity.
Simon, Tamara D; Cawthon, Mary Lawrence; Stanford, Susan; Popalisky, Jean; Lyons, Dorothy; Woodcox, Peter; Hood, Margaret; Chen, Alex Y; Mangione-Smith, Rita
2014-06-01
The goal of this study was to develop an algorithm based on International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM), codes for classifying children with chronic disease (CD) according to level of medical complexity and to assess the algorithm's sensitivity and specificity. A retrospective observational study was conducted among 700 children insured by Washington State Medicaid with ≥1 Seattle Children's Hospital emergency department and/or inpatient encounter in 2010. The gold standard population included 350 children with complex chronic disease (C-CD), 100 with noncomplex chronic disease (NC-CD), and 250 without CD. An existing ICD-9-CM-based algorithm called the Chronic Disability Payment System was modified to develop a new algorithm called the Pediatric Medical Complexity Algorithm (PMCA). The sensitivity and specificity of PMCA were assessed. Using hospital discharge data, PMCA's sensitivity for correctly classifying children was 84% for C-CD, 41% for NC-CD, and 96% for those without CD. Using Medicaid claims data, PMCA's sensitivity was 89% for C-CD, 45% for NC-CD, and 80% for those without CD. Specificity was 90% to 92% in hospital discharge data and 85% to 91% in Medicaid claims data for all 3 groups. PMCA identified children with C-CD (who have accessed tertiary hospital care) with good sensitivity and good to excellent specificity when applied to hospital discharge or Medicaid claims data. PMCA may be useful for targeting resources such as care coordination to children with C-CD. Copyright © 2014 by the American Academy of Pediatrics.
Pediatric Medical Complexity Algorithm: A New Method to Stratify Children by Medical Complexity
Cawthon, Mary Lawrence; Stanford, Susan; Popalisky, Jean; Lyons, Dorothy; Woodcox, Peter; Hood, Margaret; Chen, Alex Y.; Mangione-Smith, Rita
2014-01-01
OBJECTIVES: The goal of this study was to develop an algorithm based on International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM), codes for classifying children with chronic disease (CD) according to level of medical complexity and to assess the algorithm’s sensitivity and specificity. METHODS: A retrospective observational study was conducted among 700 children insured by Washington State Medicaid with ≥1 Seattle Children’s Hospital emergency department and/or inpatient encounter in 2010. The gold standard population included 350 children with complex chronic disease (C-CD), 100 with noncomplex chronic disease (NC-CD), and 250 without CD. An existing ICD-9-CM–based algorithm called the Chronic Disability Payment System was modified to develop a new algorithm called the Pediatric Medical Complexity Algorithm (PMCA). The sensitivity and specificity of PMCA were assessed. RESULTS: Using hospital discharge data, PMCA’s sensitivity for correctly classifying children was 84% for C-CD, 41% for NC-CD, and 96% for those without CD. Using Medicaid claims data, PMCA’s sensitivity was 89% for C-CD, 45% for NC-CD, and 80% for those without CD. Specificity was 90% to 92% in hospital discharge data and 85% to 91% in Medicaid claims data for all 3 groups. CONCLUSIONS: PMCA identified children with C-CD (who have accessed tertiary hospital care) with good sensitivity and good to excellent specificity when applied to hospital discharge or Medicaid claims data. PMCA may be useful for targeting resources such as care coordination to children with C-CD. PMID:24819580
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, M. J.; Uhl, J. R.; Sloan, L. M.; Buckwalter, S. P.; Jones, M. F.; Vetter, E. A.; Yao, J. D. C.; Wengenack, N. L.; Rosenblatt, J. E.; Cockerill, F. R.; Smith, T. F.
2006-01-01
Real-time PCR has revolutionized the way clinical microbiology laboratories diagnose many human microbial infections. This testing method combines PCR chemistry with fluorescent probe detection of amplified product in the same reaction vessel. In general, both PCR and amplified product detection are completed in an hour or less, which is considerably faster than conventional PCR detection methods. Real-time PCR assays provide sensitivity and specificity equivalent to that of conventional PCR combined with Southern blot analysis, and since amplification and detection steps are performed in the same closed vessel, the risk of releasing amplified nucleic acids into the environment is negligible. The combination of excellent sensitivity and specificity, low contamination risk, and speed has made real-time PCR technology an appealing alternative to culture- or immunoassay-based testing methods for diagnosing many infectious diseases. This review focuses on the application of real-time PCR in the clinical microbiology laboratory. PMID:16418529
A flexible piezoelectric force sensor based on PVDF fabrics
NASA Astrophysics Data System (ADS)
Wang, Y. R.; Zheng, J. M.; Ren, G. Y.; Zhang, P. H.; Xu, C.
2011-04-01
Polyvinylidene fluoride (PVDF) film has been widely investigated as a sensor and transducer material due to its high piezo-, pyro- and ferroelectric properties. To activate these properties, PVDF films require a mechanical treatment, stretching or poling. In this paper, we report on a force sensor based on PVDF fabrics with excellent flexibility and breathability, to be used as a specific human-related sensor. PVDF nanofibrous fabrics were prepared by using an electrospinning unit and characterized by means of scanning electron microscopy (SEM), FTIR spectroscopy and x-ray diffraction. Preliminary force sensors have been fabricated and demonstrated excellent sensitivity and response to external mechanical forces. This implies that promising applications can be made for sensing garment pressure, blood pressure, heartbeat rate, respiration rate and accidental impact on the human body.
Highly sensitive Europium doped SrSO4 OSL nanophosphor for radiation dosimetry applications
NASA Astrophysics Data System (ADS)
Patle, Anita; Patil, R. R.; Kulkarni, M. S.; Bhatt, B. C.; Moharil, S. V.
2015-10-01
Highly sensitive Europium doped SrSO4 optically stimulated luminescent (OSL) phosphor was developed by synthesizing a nano phosphor which is treated at 1000 °C. Excellent OSL properties are observed in the developed phosphor and the sensitivity is found to be 1.26 times to that of the commercial Al2O3:C (Landauer Inc.) phosphor based on area integration method. The sample showed a single TL glow peak around 230 °C which is found to reduce by 47% after the OSL readout. Sublinear dose response with the saturation around 100 mGy is observed in this sample which suggests that it is extremely sensitive and hence will be suitable in detecting very low dose levels. Minimum measurable dose on the used set up is estimated to be 1.42 μGy. Practically no fading is observed for first ten days and the phosphor has excellent reusability. High sensitivity, low fading, excellent reusability will make this phosphor suitable for radiation dosimetry applications using OSL.
Performance characteristics of the ARCHITECT anti-HCV assay.
Jonas, Gesa; Pelzer, Claudia; Beckert, Christian; Hausmann, Michael; Kapprell, Hans-Peter
2005-10-01
The ARCHITECT Anti-HCV assay is a fully automated high throughput chemiluminescent microparticle immunoassay (CMIA) for the detection of antibodies to structural and nonstructural proteins of the hepatitis C virus (HCV). To further enhance the performance of this test, the assay was modified to improve the specificity for blood donor specimens. The specificity of the enhanced ARCHITECT Anti-HCV assay was evaluated by screening blood donor samples randomly collected from various German blood banks, as well as hospitalized patient samples derived from Germany and the US. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels and on a commercially available worldwide anti-HCV genotype performance panel. Apparent specificity of the modified ARCHITECT Anti-HCV assay in a blood donor population consisting of 3811 specimens was 99.92%, compared to 99.76% for the current on-market assay. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels. Seroconversion sensitivity equivalent to or better than the current on-market product was observed by testing 33 seroconversion panels. This study demonstrates that the modified version of the ARCHITECT Anti-HCV assay shows improved specificity for blood donor specimens compared to the current assay on market without compromising sensitivity. With the availability of the improved ARCHITECT Anti-HCV assay and the recent launch of the ARCHITECT HIV Ag/Ab Combo assay, the ARCHITECT system now offers a full hepatitis/retrovirus menu with excellent performance on a high throughput, random access, automated analyzer, ideally suited for blood screening and diagnostic applications.
Jahan-Tigh, Richard R; Chinn, Garrett M; Rapini, Ronald P
2016-01-01
The incorporation of high-resolution cameras into smartphones has allowed for a variety of medical applications including the use of lens attachments that provide telescopic, macroscopic, and dermatoscopic data, but the feasibility and performance characteristics of such a platform for use in dermatopathology have not been described. To determine the diagnostic performance of a smartphone microscope compared to traditional light microscopy in dermatopathology specimens. A simple smartphone microscope constructed with a 3-mm ball lens was used to prospectively evaluate 1021 consecutive dermatopathology cases in a blinded fashion. Referred, consecutive specimens from the community were evaluated at a single university hospital. The performance characteristics of the smartphone platform were calculated by using conventional light microscopy as the gold standard. The sensitivity and specificity for the diagnosis of melanoma, nonmelanoma skin cancers, and other miscellaneous conditions by the phone microscopy platform, as compared with traditional light microscopy, were calculated. For basal cell carcinoma (n = 136), the sensitivity and specificity of smartphone microscopy were 95.6% and 98.1%, respectively. The sensitivity and specificity for squamous cell carcinoma (n = 94) were 89.4% and 97.3%, respectively. The lowest sensitivity was found in melanoma (n = 15) at 60%, although the specificity was high at 99.1%. The accuracy of diagnosis of inflammatory conditions and other neoplasms was variable. Mobile phone-based microscopy has excellent performance characteristics for the inexpensive diagnosis of nonmelanoma skin cancers in a setting where a traditional microscope is not available.
Genetic point-of-care diagnosis of Mycoplasma pneumoniae infection using LAMP assay.
Kakuya, Fujio; Kinebuchi, Takahiro; Fujiyasu, Hiroaki; Tanaka, Ryosuke; Kano, Hiroki
2014-08-01
Mycoplasma pneumoniae (MP) is a major pathogen of lower respiratory tract infection (LRTI) in children. A rapid diagnostic method during the acute phase is required for the prescription of effective antibiotics. A prospective, single-centered study was conducted on community-acquired LRTI in children. We regarded the day of fever onset as the first day of illness. In part 1, we studied 191 patients with signs of LRTI. We compared diagnostic reliability using loop-mediated isothermal amplification (LAMP) assay and serological testing at the first visit. In part 2, we evaluated the clinical characteristics of 117 patients with positive LAMP assay. In part 1, 31 patients met the definite MP infection criteria. LAMP assay had a sensitivity of 96.8% and specificity of 100%, whereas enzyme immunoassay had a sensitivity of 38.7% and specificity of 76.9%, and particle agglutination test had a sensitivity of 19.4% and specificity of 93.1%. In part 2, of 106 patients with fever, 100 patients were diagnosed by the day 7 of illness. The diagnosis was made a mean of 3.5 ± 2.1 days after the onset of fever. LAMP assay had excellent sensitivity and specificity for the detection of acute MP infection at the first visit. This assay can diagnose MP infection during the very acute phase. LAMP assay is appropriate for genetic point-of-care diagnosis of MP infection in hospital laboratories. © 2014 Japan Pediatric Society.
Yang, Weijuan; Zhang, Hongyan; Li, Mengxue; Wang, Zonghua; Zhou, Jie; Wang, Shihua; Lu, Guodong; Fu, FengFu
2014-11-19
As one of the most destructive and widespread disease of rice, Magnaporthe oryzae (also called Magnaporthe grisea) has a significant negative impact on rice production. Therefore, it is still in high demand to develop extremely sensitive and accurate methods for the early diagnosis of Magnaporthe oryzae (M. oryzae). In this study, we developed a novel magnetic-controllable electrochemical biosensor for the ultra sensitive and specific detection of M. oryzae in rice plant by using M. oryzae's chitinases (Mgchi) as biochemical marker and a rice (Oryza sativa) cDNA encoding mannose-binding jacalin-related lectin (Osmbl) as recognition probe. The proposed biosensor combined with the merits of chronoamperometry, electrically magnetic-controllable gold electrode and magnetic beads (MBs)-based palladium nano-particles (PdNPs) catalysis amplification, has an ultra-high sensitivity and specificity for the detection of trace M. oryzae in rice plant. It could be used to detect M. oryzae in rice plant in the initial infection stage (before any symptomatic lesions were observed) to help farmers timely manage the disease. In comparison with previous methods, the proposed method has notable advantages such as higher sensitivity, excellent specificity, short analysis time, robust resistibility to complex matrix and low cost etc. The success in this study provides a reliable approach for the early diagnosis and fast screening of M. oryzae in rice plant. Copyright © 2014 Elsevier B.V. All rights reserved.
Ha, Jihye; Park, Younhee; Kim, Hyon-Suk
2017-11-01
Transfusion-transmitted infectious diseases remain a major concern for blood safety, particularly with hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV). Nucleic acid testing (NAT) in donor screening shortens the serologically negative window period and reduces virus transmission. The cobas MPX (Roche Molecular Systems, Inc., Branchburg, New Jersey) is a recently developed multiplex qualitative PCR system that enables the simultaneous detection of HBV, HCV, and HIV with improved sensitivity and throughput using cobas 6800 and 8800 instruments. The aim of this study was to conduct an evaluation of the clinical sensitivity and specificity of cobas MPX detection of HBV, HCV, and HIV in clinical specimens. Among samples referred for HBV, HCV, and HIV-1 quantification at Severance Hospital, Yonsei University College of Medicine, positive samples were selected to evaluate sensitivity. A total of 843 samples was tested using both cobas MPX and COBAS AmpliPrep/COBAS TaqMan Tests for HBV, HCV, and HIV-1 using the cobas 8800 system and a COBAS TaqMan 96 analyzer, respectively. Samples that showed discrepancies were confirmed by nested PCR. The cobas MPX achieved excellent sensitivity and specificity for the detection of HBV, HCV, and HIV-1 in clinical samples. We found that the lower limit of detection (LOD) of blood screening by NAT actually improves clinical sensitivity, and occult HBV infection prevalence among healthy employees of the hospital was rather high. Copyright © 2017 Elsevier B.V. All rights reserved.
Thyroid Nodule Classification in Ultrasound Images by Fine-Tuning Deep Convolutional Neural Network.
Chi, Jianning; Walia, Ekta; Babyn, Paul; Wang, Jimmy; Groot, Gary; Eramian, Mark
2017-08-01
With many thyroid nodules being incidentally detected, it is important to identify as many malignant nodules as possible while excluding those that are highly likely to be benign from fine needle aspiration (FNA) biopsies or surgeries. This paper presents a computer-aided diagnosis (CAD) system for classifying thyroid nodules in ultrasound images. We use deep learning approach to extract features from thyroid ultrasound images. Ultrasound images are pre-processed to calibrate their scale and remove the artifacts. A pre-trained GoogLeNet model is then fine-tuned using the pre-processed image samples which leads to superior feature extraction. The extracted features of the thyroid ultrasound images are sent to a Cost-sensitive Random Forest classifier to classify the images into "malignant" and "benign" cases. The experimental results show the proposed fine-tuned GoogLeNet model achieves excellent classification performance, attaining 98.29% classification accuracy, 99.10% sensitivity and 93.90% specificity for the images in an open access database (Pedraza et al. 16), while 96.34% classification accuracy, 86% sensitivity and 99% specificity for the images in our local health region database.
Highly sensitive dendrimer-based nanoplasmonic biosensor for drug allergy diagnosis.
Soler, Maria; Mesa-Antunez, Pablo; Estevez, M-Carmen; Ruiz-Sanchez, Antonio Jesus; Otte, Marinus A; Sepulveda, Borja; Collado, Daniel; Mayorga, Cristobalina; Torres, Maria Jose; Perez-Inestrosa, Ezequiel; Lechuga, Laura M
2015-04-15
A label-free biosensing strategy for amoxicillin (AX) allergy diagnosis based on the combination of novel dendrimer-based conjugates and a recently developed nanoplasmonic sensor technology is reported. Gold nanodisks were functionalized with a custom-designed thiol-ending-polyamido-based dendron (d-BAPAD) peripherally decorated with amoxicilloyl (AXO) groups (d-BAPAD-AXO) in order to detect specific IgE generated in patient's serum against this antibiotic during an allergy outbreak. This innovative strategy, which follows a simple one-step immobilization procedure, shows exceptional results in terms of sensitivity and robustness, leading to a highly-reproducible and long-term stable surface which allows achieving extremely low limits of detection. Moreover, the viability of this biosensor approach to analyze human biological samples has been demonstrated by directly analyzing and quantifying specific anti-AX antibodies in patient's serum without any sample pretreatment. An excellent limit of detection (LoD) of 0.6ng/mL (i.e. 0.25kU/L) has been achieved in the evaluation of clinical samples evidencing the potential of our nanoplasmonic biosensor as an advanced diagnostic tool to quickly identify allergic patients. The results have been compared and validated with a conventional clinical immunofluorescence assay (ImmunoCAP test), confirming an excellent correlation between both techniques. The combination of a novel compact nanoplasmonic platform and a dendrimer-based strategy provides a highly sensitive label free biosensor approach with over two times better detectability than conventional SPR. Both the biosensor device and the carrier structure hold great potential in clinical diagnosis for biomarker analysis in whole serum samples and other human biological samples. Copyright © 2014 Elsevier B.V. All rights reserved.
2017-07-07
RESEARCH ARTICLE Self-reported HIV-positive status but subsequent HIV-negative test result using rapid diagnostic testing algorithms among seven sub...America * judith.harbertson.ctr@mail.mil Abstract HIV rapid diagnostic tests (RDTs) combined in an algorithm are the current standard for HIV diagnosis...in many sub-Saharan African countries, and extensive laboratory testing has con- firmed HIV RDTs have excellent sensitivity and specificity. However
Yu, Haixiang; Canoura, Juan; Guntupalli, Bhargav; Lou, Xinhui
2017-01-01
Sensors employing split aptamers that reassemble in the presence of a target can achieve excellent specificity, but the accompanying reduction of target affinity mitigates any overall gains in sensitivity. We for the first time have developed a split aptamer that achieves enhanced target-binding affinity through cooperative binding. We have generated a split cocaine-binding aptamer that incorporates two binding domains, such that target binding at one domain greatly increases the affinity of the second domain. We experimentally demonstrate that the resulting cooperative-binding split aptamer (CBSA) exhibits higher target binding affinity and is far more responsive in terms of target-induced aptamer assembly compared to the single-domain parent split aptamer (PSA) from which it was derived. We further confirm that the target-binding affinity of our CBSA can be affected by the cooperativity of its binding domains and the intrinsic affinity of its PSA. To the best of our knowledge, CBSA-5335 has the highest cocaine affinity of any split aptamer described to date. The CBSA-based assay also demonstrates excellent performance in target detection in complex samples. Using this CBSA, we achieved specific, ultra-sensitive, one-step fluorescence detection of cocaine within fifteen minutes at concentrations as low as 50 nM in 10% saliva without signal amplification. This limit of detection meets the standards recommended by the European Union's Driving under the Influence of Drugs, Alcohol and Medicines program. Our assay also demonstrates excellent reproducibility of results, confirming that this CBSA-platform represents a robust and sensitive means for cocaine detection in actual clinical samples. PMID:28451157
NASA Astrophysics Data System (ADS)
Wang, Dandan; Cai, Daoping; Wang, Chenxia; Liu, Bin; Wang, Lingling; Liu, Yuan; Li, Han; Wang, Yanrong; Li, Qiuhong; Wang, Taihong
2016-06-01
A muti-component nanocomposite of nickel and manganese oxides with a uniformly dispersed microspherical structure has been fabricated by a hydrothermal synthesis method. The as-prepared nanocomposite has been employed as a sensing material for non-enzymatic glucose detection and shown excellent electrocatalytic activity, such as high sensitivities of 82.44 μA mM-1 cm-2 and 27.92 μA mM-1 cm-2 over the linear range of 0.1-1 mM and 1-4.5 mM, respectively, a low detection limit of 0.2 μM and a fast response time of <3 s. Moreover, satisfactory specificity and excellent stability have also been achieved. The results demonstrate that a muti-component nanocomposite of nickel and manganese oxides has great potential applications as glucose sensors.
Quinn, S F; Neubauer, N M; Sheley, R C; Demlow, T A; Szumowski, J
1996-01-01
MR imaging was used to evaluate the integrity of silicone breast implants in 54 women with 108 implants. MR images were interpreted by relatively inexperienced readers who tried to reproduce the experiences reported in the literature. The study examines the interobserver agreement using different diagnostic signs and the influence of experience on interpretation errors. Prospective and retrospective interpretations were compared with surgical findings at the time of explanation. Diagnostic indicators, including the linguine sign, the inverted tear drop sign, the C sign, water droplets mixed with silicone, and extracapsular globules of silicone, were evaluated for diagnostic efficacy and interobserver agreement. The prospective sensitivity and specificity were 87% and 78%, respectively. With the retrospective interpretations, the sensitivity and specificity increased to 93% and 92%, respectively. Most of the prospective false-positive interpretations were due to misinterpreting radial folds as signs of implant rupture. Six implants interpreted retrospectively as false positives had gross amounts of silicone around the implants at surgery but there were no obvious rents in the implant shells. There was fair to excellent interobserver agreement with the individual diagnostic signs except for extracapsular globules of silicone. All of the signs had specificities of greater than 90%. The sensitivities of the individual signs were less than the overall retrospective sensitivity. With experience, the sensitivity improved from 87% to 93% and the specificity improved from 78% to 92%. This study helps substantiate the use of diagnostic signs used by other authors to detect silicone loss from breast implants by MR imaging; however, questions remain as to the clinical role of MR imaging in evaluating implants for silicone loss.
Masciarelli, Amanda E; Griffin, John F; Fosgate, Geoffrey T; Hecht, Silke; Mankin, Joseph M; Holmes, Shannon P; Platt, Simon R; Kent, Marc; Pancotto, Theresa E; Chen, Annie V; Levine, Jonathan M
2017-07-01
Magnetic resonance imaging (MRI) is a common test for dogs with suspected intradural spinal cord lesions, however studies on diagnostic performance for this test are lacking. Objectives of this multi-institutional, retrospective, case-control study were to estimate sensitivity and specificity of MRI for (1) distinguishing between histopathologically confirmed intradural spinal cord disease versus degenerative myelopathy in dogs, (2) categorizing intradural spinal cord diseases as neoplastic, inflammatory, or vascular; and (3) determining tumor type within the etiologic category of neoplasia. Additional aims were to (1) determine whether knowledge of clinical data affects sensitivity and specificity of MRI diagnoses; and (2) report interrater agreement for MRI classification of intradural spinal lesions. Cases were recruited from participating hospital databases over a 7-year period. Three reviewers independently evaluated each MRI study prior to and after provision of clinical information. A total of 87 cases were sampled (17 degenerative myelopathy, 53 neoplasia, nine inflammatory, and eight vascular). Magnetic resonance imaging had excellent (>97.6%) sensitivity for diagnosis of intradural spinal cord lesions but specificity varied before and after provision of clinical data (68.6% vs. 82.4%, P = 0.023). Magnetic resonance imaging had good sensitivity (86.8%) and moderate specificity (64.7-72.5%) for diagnosing neoplasia. Sensitivity was lower for classifying inflammatory lesions but improved with provision of clinical data (48.1% vs. 81.5%, P = 0.015). Magnetic resonance imaging was insensitive for diagnosing vascular lesions (25.0%). Interrater agreement was very good for correctly diagnosing dogs with intradural lesions (ĸ = 0.882-0.833), and good (ĸ = 0.726-0.671) for diagnosing dogs with neoplasia. © 2017 American College of Veterinary Radiology.
NASA Astrophysics Data System (ADS)
Zhang, Wancun; Zhang, Qi; Qian, Zhiyu; Gu, Yueqing
2017-02-01
MicroRNAs (miRNAs) play important roles in a wide range of biological processes, including proliferation, development, metabolism, immunological response, tumorigenesis, and viral infection. The detection of miRNAs is imperative for gaining a better understanding of the functions of these biomolecules and has great potential for the early diagnosis of human disease as well as the discovery of new drugs through the use of miRNAs as targets. In this article, we develop a highly sensitive, and specific miRNA assay based on the two-stage isothermal amplification reactions and molecular beacon. The two-stage isothermal amplification reactions involves two templates and two-stage amplification reactions under isothermal conditions. The first template enables the amplification of miRNA, and the second template enables the conversion of miRNA to the reporter oligonucleotide(Y). Importantly, different miRNAs can be converted to the same Y seperately, which can hybridize with the same set of molecular beacon to generate fluorescent signals. This assay is highly sensitive and specific with a detection limit of 1 fM and can even discriminate single-nucleotide differences. Moreover, in combination with the specific templates, this method can be applied for multiplex miRNA assay by simply using the same molecular beacon. This method has potential to become a promising miRNA quantification method in biomedical research and clinical diagnosis.
Unconventional imaging with contained granular media
NASA Astrophysics Data System (ADS)
Quadrelli, Marco B.; Basinger, Scott; Sidick, Erkin
2017-09-01
Typically, the cost of a space-borne imaging system is driven by the size and mass of the primary aperture. The solution that we propose uses a method to construct an imaging system in space in which the nonlinear optical properties of a cloud of micron-sized particles, shaped into a specific surface by electromagnetic means, and allows one to form a very large and lightweight aperture of an optical system, hence reducing overall mass and cost. Recent work at JPL has investigated the feasibility of a granular imaging system, concluding that such a system could be built and controlled in orbit. We conducted experiments and simulation of the optical response of a granular lens. In all cases, the optical response, measured by the Modulation Transfer Function, of hexagonal reflectors was closely comparable to that of a conventional spherical mirror. We conducted some further analyses by evaluating the sensitivity to fill factor and grain shape, and found a marked sensitivity to fill factor but no sensitivity to grain shape. We have also found that at fill factors as low as 30%, the reflection from a granular lens is still excellent. Furthermore, we replaced the monolithic primary mirror in an existing integrated model of an optical system (WFIRST Coronagraph) with a granular lens, and found that the granular lens that can be useful for exoplanet detection provides excellent contrast levels. We will present our testbed and simulation results in this paper.
Wilkes, Rebecca P; Tsai, Yun-Long; Lee, Pei-Yu; Lee, Fu-Chun; Chang, Hsiao-Fen Grace; Wang, Hwa-Tang Thomas
2014-09-09
Canine distemper virus (CDV) has been associated with outbreaks of canine infectious respiratory disease in shelters and boarding kennel environments. POCKITTM Nucleic Acid Analyzer is a field-deployable device capable of generating automatically interpreted insulated isothermal polymerase chain reaction (iiPCR) results from extracted nucleic acid within one hour. In this study, reverse transcription iiPCR (RT-iiPCR) was developed to facilitate point-of-need diagnosis of CDV infection. Analytical sensitivity (limit of detection 95%) of the established CDV RT-iiPCR was about 11 copies of in vitro transcribed RNA per reaction. CDV RT-iiPCR generated positive signals from CDV, but not Bordetella bronchiseptica, canine parvovirus, canine herpesvirus, canine adenovirus 2, canine influenza virus (subtype H3N8), canine parainfluenza virus, and canine respiratory coronavirus. To evaluate accuracy of the established reaction in canine distemper clinical diagnosis, 110 specimens from dogs, raccoons, and foxes suspected with CDV infection were tested simultaneously by CDV RT-iiPCR and real-time RT-PCR. CDV RT-iiPCR demonstrated excellent sensitivity (100%) and specificity (100%), compared to real-time RT-PCR. The results indicated an excellent correlation between RT-iiPCR and a reference real time RT-PCR method. Working in a lyophilized format, the established method has great potential to be used for point-of-care diagnosis of canine distemper in animals, especially in resource-limited facilities.
Instrumentation in molecular imaging.
Wells, R Glenn
2016-12-01
In vivo molecular imaging is a challenging task and no single type of imaging system provides an ideal solution. Nuclear medicine techniques like SPECT and PET provide excellent sensitivity but have poor spatial resolution. Optical imaging has excellent sensitivity and spatial resolution, but light photons interact strongly with tissues and so only small animals and targets near the surface can be accurately visualized. CT and MRI have exquisite spatial resolution, but greatly reduced sensitivity. To overcome the limitations of individual modalities, molecular imaging systems often combine individual cameras together, for example, merging nuclear medicine cameras with CT or MRI to allow the visualization of molecular processes with both high sensitivity and high spatial resolution.
The association between parent worry and young children's social-emotional functioning.
Weitzman, Carol Cohen; Edmonds, Diana; Davagnino, Judith; Briggs-Gowan, Margaret
2011-11-01
: Behavioral health problems are reported to affect as many as 24% of children younger than 4 years. Screening within primary care settings remains low. Brief, inexpensive methods to identify children are needed. The objective of this study was to determine the extent to which parent worry about their children's behavior and development is associated with social-emotional problems. : In this cross-sectional study, 378 Spanish and English speaking mothers of 12- to 48-month-old, underserved children were surveyed before a well-child visit with the Brief Infant-Toddler Social-Emotional Assessment. This is a parent-report measure that was scored to identify clinically significant (CS) social-emotional problems (≥85th percentile) and at-risk (AR) problems (75th-84th percentile). Parents rated their worry about their children's behavior and social-emotional development on 3 questions. : A total of 42.1% of children had AR or CS problems or low social competence, with 19.8% of these children having CS problems. Overall, 30.4% of parents expressed worry about social-emotional/behavioral issues. A total of 19.9% of parents expressed worry despite having rated their child's behavior in the normal range on the Brief Infant-Toddler Social-Emotional Assessment. Worry was significantly associated with having either AR or CS problems. However, worry significantly distinguished the CS group, but not the AR group, from the normal group. Parent worry regarding behavior and social-emotional development approached adequate sensitivity (66.7%) to identify children CS problems with specificity being 78.6%. Parent worry, however, was not adequately sensitive in detecting AR problems. Ethnic differences indicated that the sensitivity and specificity of worry to detect CS behavior and social-emotional problems were excellent in Hispanic families, but sensitivity was poor in African-American ones. Among parents with low educational attainment, sensitivity to detect CS behavior and social-emotional problems was excellent. : Parent worry regarding social-emotional/behavioral issues may be a useful adjunct to developmental surveillance, as it identifies children with the most significant behavioral and social-emotional problems. However, as a screening method to identify all young children with social-emotional problems, parent worry does not currently achieve acceptable classification.
2011-01-01
Background The present study evaluated the SD Bioline Malaria Ag 05FK40 (SDFK40), a three-band RDT detecting Plasmodium falciparum-specific parasite lactate dehydrogenase (Pf-pLDH) and pan Plasmodium-specific pLDH (pan-pLDH), in a reference setting. Methods The SDFK40 was retrospectively and prospectively tested against a panel of stored (n = 341) and fresh (n = 181) whole blood samples obtained in international travelers suspected of malaria, representing the four Plasmodium species as well as Plasmodium negative samples, and compared to microscopy and PCR results. The prospective panel was run together with OptiMAL (Pf-pLDH/pan-pLDH) and SDFK60 (histidine-rich protein-2 (HRP-2)/pan-pLDH). Results Overall sensitivities for P. falciparum tested retrospectively and prospectively were 67.9% and 78.8%, reaching 100% and 94.6% at parasite densities >1,000/μl. Sensitivity at parasite densities ≤ 100/μl was 9.1%. Overall sensitivities for Plasmodium vivax and Plasmodium ovale were 86.7% and 80.0% (retrospectively) and 92.9% and 76.9% (prospectively), reaching 94.7% for both species (retrospective panel) at parasite densities >500/μl. Sensitivity for Plasmodium malariae was 21.4%. Species mismatch occurred in 0.7% of samples (3/411) and was limited to non-falciparum species erroneously identified as P. falciparum. None of the Plasmodium negative samples in the retrospective panel reacted positive. Compared to OptiMAL and SDFK60, SDFK40 showed lower sensitivities for P. falciparum, but better detection of P. ovale. Inter-observer agreement and test reproducibility were excellent, but lot-to-lot variability was observed for pan-pLDH results in case of P. falciparum. Conclusion SDFK40 performance was poor at low (≤ 100/μl) parasite densities, precluding its use as the only diagnostic tool for malaria diagnosis. SDFK40 performed excellent for P. falciparum samples at high (>1,000/μl) parasite densities as well as for detection of P. vivax and P. ovale at parasite densities >500/μl. PMID:21226920
Maltha, Jessica; Gillet, Philippe; Cnops, Lieselotte; Bottieau, Emmanuel; Van Esbroeck, Marjan; Bruggeman, Cathrien; Jacobs, Jan
2011-01-12
The present study evaluated the SD Bioline Malaria Ag 05FK40 (SDFK40), a three-band RDT detecting Plasmodium falciparum-specific parasite lactate dehydrogenase (Pf-pLDH) and pan Plasmodium-specific pLDH (pan-pLDH), in a reference setting. The SDFK40 was retrospectively and prospectively tested against a panel of stored (n = 341) and fresh (n = 181) whole blood samples obtained in international travelers suspected of malaria, representing the four Plasmodium species as well as Plasmodium negative samples, and compared to microscopy and PCR results. The prospective panel was run together with OptiMAL (Pf-pLDH/pan-pLDH) and SDFK60 (histidine-rich protein-2 (HRP-2)/pan-pLDH). Overall sensitivities for P. falciparum tested retrospectively and prospectively were 67.9% and 78.8%, reaching 100% and 94.6% at parasite densities >1,000/μl. Sensitivity at parasite densities ≤ 100/μl was 9.1%. Overall sensitivities for Plasmodium vivax and Plasmodium ovale were 86.7% and 80.0% (retrospectively) and 92.9% and 76.9% (prospectively), reaching 94.7% for both species (retrospective panel) at parasite densities >500/μl. Sensitivity for Plasmodium malariae was 21.4%. Species mismatch occurred in 0.7% of samples (3/411) and was limited to non-falciparum species erroneously identified as P. falciparum. None of the Plasmodium negative samples in the retrospective panel reacted positive. Compared to OptiMAL and SDFK60, SDFK40 showed lower sensitivities for P. falciparum, but better detection of P. ovale. Inter-observer agreement and test reproducibility were excellent, but lot-to-lot variability was observed for pan-pLDH results in case of P. falciparum. SDFK40 performance was poor at low (≤ 100/μl) parasite densities, precluding its use as the only diagnostic tool for malaria diagnosis. SDFK40 performed excellent for P. falciparum samples at high (>1,000/μl) parasite densities as well as for detection of P. vivax and P. ovale at parasite densities >500/μl.
Thongdee, Pimwan; Chaijaroenkul, Wanna; Kuesap, Jiraporn; Na-Bangchang, Kesara
2014-08-01
Microscopy is considered as the gold standard for malaria diagnosis although its wide application is limited by the requirement of highly experienced microscopists. PCR and serological tests provide efficient diagnostic performance and have been applied for malaria diagnosis and research. The aim of this study was to investigate the diagnostic performance of nested PCR and a recently developed an ELISA-based new rapid diagnosis test (RDT), NovaLisa test kit, for diagnosis of malaria infection, using microscopic method as the gold standard. The performance of nested-PCR as a malaria diagnostic tool is excellent with respect to its high accuracy, sensitivity, specificity, and ability to discriminate Plasmodium species. The sensitivity and specificity of nested-PCR compared with the microscopic method for detection of Plasmodium falciparum, Plasmodium vivax, and P. falciparum/P. vivax mixed infection were 71.4 vs 100%, 100 vs 98.7%, and 100 vs 95.0%, respectively. The sensitivity and specificity of the ELISA-based NovaLisa test kit compared with the microscopic method for detection of Plasmodium genus were 89.0 vs 91.6%, respectively. NovaLisa test kit provided comparable diagnostic performance. Its relatively low cost, simplicity, and rapidity enables large scale field application.
Predictive simulations and optimization of nanowire field-effect PSA sensors including screening
NASA Astrophysics Data System (ADS)
Baumgartner, Stefan; Heitzinger, Clemens; Vacic, Aleksandar; Reed, Mark A.
2013-06-01
We apply our self-consistent PDE model for the electrical response of field-effect sensors to the 3D simulation of nanowire PSA (prostate-specific antigen) sensors. The charge concentration in the biofunctionalized boundary layer at the semiconductor-electrolyte interface is calculated using the propka algorithm, and the screening of the biomolecules by the free ions in the liquid is modeled by a sensitivity factor. This comprehensive approach yields excellent agreement with experimental current-voltage characteristics without any fitting parameters. Having verified the numerical model in this manner, we study the sensitivity of nanowire PSA sensors by changing device parameters, making it possible to optimize the devices and revealing the attributes of the optimal field-effect sensor.
Pan, Jie; Liu, Wei-Jiao; Hua, Chao; Wang, Li-Li; Wan, Dong; Gong, Jun-Bo
2015-01-01
Objective To fabricate polymeric nanocomposites with excellent photoluminescence, magnetic properties, and stability in aqueous solutions, in order to improve specificity and sensitivity of cellular imaging under a magnetic field. Methods Fluoridated Ln3+-doped HAP (Ln3+-HAP) NPs and iron oxides (IOs) can be encapsulated with biocompatible polymers via a modified solvent exaction/evaporation technique to prepare polymeric nanocomposites with fluoridated Ln3+-HAP/iron oxide. The nanocomposites were characterized for surface morphology, fluorescence spectra, magnetic properties and in vitro cytotoxicity. Magnetic targeted cellular imaging of such nanocomposites was also evaluated with confocal laser scanning microscope using A549 cells with or without magnetic field. Results The fabricated nanocomposites showed good stability and excellent luminescent properties, as well as low in vitro cytotoxicity, indicating that the nanocomposites are suitable for biological applications. Nanocomposites under magnetic field achieved much higher cellular uptake via an energy-dependent pathway than those without magnetic field. Conclusion The nanocomposites fabricated in this study will be a promising tool for magnetic targeted cellular imaging with improved specificity and enhanced selection. PMID:26487962
Ortiz-Arroyo, Víctor M; Granados, Julio; Uribe-Uribe, Norma; de Leo, Claudia; Castelán, Natalia; González, Norma; López, Mayra; Alberú, Josefina
2004-01-01
Pregnancy is a known cause of immunological sensitization and it has been reported graft survival to be lower in husband to wife kidney transplantation if the wife had been pregnant (mutual children) as compare to those cases without pregnancies. Previous exposure to husband HLA antigens during pregnancies may lead to specific sensitization to subsequent allografts. To communicate the fate of kidney allograft in husband to wife transplantation when the recipient had been pregnant. From 682 renal transplants performed at INCMNSZ 5 corresponded to husband to wife transplants. All the recipients were multiparous and had received multiple blood transfusions. Pretransplantation lymphocytotoxic cross-match testing were performed by complement dependent citotoxicity with antihuman globulin added (AHG-CDC), being negative in all cases for T and B cells. All the patients received triple-drug immunosuppressive therapy, additionally, anti-IL2R monoclonal antibodies were used in two cases. Two patients developed: accelerated acute rejection (case 1), and acute humoral rejection (case 5), respectively. Graft in these patients were loss to rejection and transplant nephrectomy accomplished. The remaining three patients (cases 2, 3, and 4) has not had any rejection episode, and have had excellent graft outcome at 34, 30, and 21 months posttransplant, respectively. Why under similar conditions some husband to wife kidney transplant recipients developed an adverse humoral immunological events while others maintain excellent long-term graft outcome? Is it possible to speculate that for some women pregnancy is in fact a sensitizing event, while in others it promotes "immunological acceptance"? At present there is no a test that characterized one and other group. Even though pretransplantation cross-match testing by flow cytometry is more sensitive than AHG-CDC, its negative result is by no means an absolute guarantee that an adverse anamnestic immunological event will not occur.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tang, Guoping; Mayes, Melanie; Parker, Jack C
2010-01-01
We implemented the widely used CXTFIT code in Excel to provide flexibility and added sensitivity and uncertainty analysis functions to improve transport parameter estimation and to facilitate model discrimination for multi-tracer experiments on structured soils. Analytical solutions for one-dimensional equilibrium and nonequilibrium convection dispersion equations were coded as VBA functions so that they could be used as ordinary math functions in Excel for forward predictions. Macros with user-friendly interfaces were developed for optimization, sensitivity analysis, uncertainty analysis, error propagation, response surface calculation, and Monte Carlo analysis. As a result, any parameter with transformations (e.g., dimensionless, log-transformed, species-dependent reactions, etc.) couldmore » be estimated with uncertainty and sensitivity quantification for multiple tracer data at multiple locations and times. Prior information and observation errors could be incorporated into the weighted nonlinear least squares method with a penalty function. Users are able to change selected parameter values and view the results via embedded graphics, resulting in a flexible tool applicable to modeling transport processes and to teaching students about parameter estimation. The code was verified by comparing to a number of benchmarks with CXTFIT 2.0. It was applied to improve parameter estimation for four typical tracer experiment data sets in the literature using multi-model evaluation and comparison. Additional examples were included to illustrate the flexibilities and advantages of CXTFIT/Excel. The VBA macros were designed for general purpose and could be used for any parameter estimation/model calibration when the forward solution is implemented in Excel. A step-by-step tutorial, example Excel files and the code are provided as supplemental material.« less
Evaluation of the OnSite malaria rapid test performance in Miandrivazo, Madagascar.
Ravaoarisoa, E; Andriamiandranoro, T; Raherinjafy, R; Jahevitra, M; Razanatsiorimalala, S; Andrianaranjaka, V; Randrianarivelojosia, M
2017-10-01
The performance of the malaria rapid diagnostic test OnSite-for detecting pan specific pLDH and Plasmodium falciparum specific HRP2 - was assessed during the malaria transmission peak period in Miandrivazo, in the southwestern part of Madagascar from April 20 to May 6, 2010. At the laboratory, the quality control OnSite Malaria Rapid Test according to the WHO/TDR/FIND method demonstrated that the test had good sensitivity. Of the 218 OnSite tests performed at the Miandrivazo Primary Health Center on patients with fever or a recent history of fever, four (1.8%, 95% CI: 0.6-4.9%) were invalid. Ninety four (43,1%) cases of malaria were confirmed by microscopy, of which 90 were P. falciparum malaria and 4 Plasmodium vivax malaria. With a Cohen's kappa coefficient of 0.94, the agreement between microscopy and OnSite is excellent. Compared with the rapid test CareStart™ commonly used within the public health structures in Madagascar, the sensitivity and specificity of the OnSite test were 97.9% and 96.8%.
Fu, Lawrence D.; Aphinyanaphongs, Yindalon; Wang, Lily; Aliferis, Constantin F.
2011-01-01
Evaluating the biomedical literature and health-related websites for quality are challenging information retrieval tasks. Current commonly used methods include impact factor for journals, PubMed’s clinical query filters and machine learning-based filter models for articles, and PageRank for websites. Previous work has focused on the average performance of these methods without considering the topic, and it is unknown how performance varies for specific topics or focused searches. Clinicians, researchers, and users should be aware when expected performance is not achieved for specific topics. The present work analyzes the behavior of these methods for a variety of topics. Impact factor, clinical query filters, and PageRank vary widely across different topics while a topic-specific impact factor and machine learning-based filter models are more stable. The results demonstrate that a method may perform excellently on average but struggle when used on a number of narrower topics. Topic adjusted metrics and other topic robust methods have an advantage in such situations. Users of traditional topic-sensitive metrics should be aware of their limitations. PMID:21419864
Bartoli, Francesco; Crocamo, Cristina; Biagi, Enrico; Di Carlo, Francesco; Parma, Francesca; Madeddu, Fabio; Capuzzi, Enrico; Colmegna, Fabrizia; Clerici, Massimo; Carrà, Giuseppe
2016-08-01
There is a lack of studies testing accuracy of fast screening methods for alcohol use disorder in mental health settings. We aimed at estimating clinical utility of a standard single-item test for case finding and screening of DSM-5 alcohol use disorder among individuals suffering from anxiety and mood disorders. We recruited adults consecutively referred, in a 12-month period, to an outpatient clinic for anxiety and depressive disorders. We assessed the National Institute on Alcohol Abuse and Alcoholism (NIAAA) single-item test, using the Mini- International Neuropsychiatric Interview (MINI), plus an additional item of Composite International Diagnostic Interview (CIDI) for craving, as reference standard to diagnose a current DSM-5 alcohol use disorder. We estimated sensitivity and specificity of the single-item test, as well as positive and negative Clinical Utility Indexes (CUIs). 242 subjects with anxiety and mood disorders were included. The NIAAA single-item test showed high sensitivity (91.9%) and specificity (91.2%) for DSM-5 alcohol use disorder. The positive CUI was 0.601, whereas the negative one was 0.898, with excellent values also accounting for main individual characteristics (age, gender, diagnosis, psychological distress levels, smoking status). Testing for relevant indexes, we found an excellent clinical utility of the NIAAA single-item test for screening true negative cases. Our findings support a routine use of reliable methods for rapid screening in similar mental health settings. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Garcia, Jessica; Forestier, Julien; Dusserre, Eric; Wozny, Anne-Sophie; Geiguer, Florence; Merle, Patrick; Tissot, Claire; Ferraro-Peyret, Carole; Jones, Frederick S; Edelstein, Daniel L; Cheynet, Valérie; Bardel, Claire; Vilchez, Gaelle; Xu, Zhenyu; Bringuier, Pierre Paul; Barritault, Marc; Brengle-Pesce, Karen; Guillet, Marielle; Chauvenet, Marion; Manship, Brigitte; Brevet, Marie; Rodriguez-Lafrasse, Claire; Hervieu, Valérie; Couraud, Sébastien; Walter, Thomas; Payen, Léa
2018-04-20
CfDNA samples from colon (mCRC) and non-small cell lung cancers (NSCLC) (CIRCAN cohort) were compared using three platforms: droplet digital PCR (ddPCR, Biorad); BEAMing/OncoBEAM™-RAS-CRC (Sysmex Inostics); next-generation sequencing (NGS, Illumina), utilizing the 56G oncology panel (Swift Biosciences). Tissue biopsy and time matched cfDNA samples were collected at diagnosis in the mCRC cohort and during 1st progression in the NSCLC cohort. Excellent matches between cfDNA/FFPE mutation profiles were observed. Detection thresholds were between 0.5-1% for cfDNA samples examined using ddPCR and NGS, and 0.03% with BEAMing. This high level of sensitivity enabled the detection of KRAS mutations in 5/19 CRC patients with negative FFPE profiles. In the mCRC cohort, comparison of mutation results obtained by testing FFPE to those obtained by testing cfDNA by ddPCR resulted in 47% sensitivity, 77% specificity, 70% positive predictive value (PPV) and 55% negative predictive value (NPV). For BEAMing, we observed 93% sensitivity, 69% specificity, 78% PPV and 90% NPV. Finally, sensitivity of NGS was 73%, specificity was 77%, PPV 79% and NPV 71%. Our study highlights the complementarity of different diagnostic approaches and variability of results between OncoBEAM™-RAS-CRC and NGS assays. While the NGS assay provided a larger breadth of coverage of the major targetable alterations of 56 genes in one run, its performance for specific alterations was frequently confirmed by ddPCR results.
Garcia, Jessica; Forestier, Julien; Dusserre, Eric; Wozny, Anne-Sophie; Geiguer, Florence; Merle, Patrick; Tissot, Claire; Ferraro-Peyret, Carole; Jones, Frederick S.; Edelstein, Daniel L.; Cheynet, Valérie; Bardel, Claire; Vilchez, Gaelle; Xu, Zhenyu; Bringuier, Pierre Paul; Barritault, Marc; Brengle-Pesce, Karen; Guillet, Marielle; Chauvenet, Marion; Manship, Brigitte; Brevet, Marie; Rodriguez-Lafrasse, Claire; Hervieu, Valérie; Couraud, Sébastien; Walter, Thomas; Payen, Léa
2018-01-01
CfDNA samples from colon (mCRC) and non-small cell lung cancers (NSCLC) (CIRCAN cohort) were compared using three platforms: droplet digital PCR (ddPCR, Biorad); BEAMing/OncoBEAM™-RAS-CRC (Sysmex Inostics); next-generation sequencing (NGS, Illumina), utilizing the 56G oncology panel (Swift Biosciences). Tissue biopsy and time matched cfDNA samples were collected at diagnosis in the mCRC cohort and during 1st progression in the NSCLC cohort. Excellent matches between cfDNA/FFPE mutation profiles were observed. Detection thresholds were between 0.5–1% for cfDNA samples examined using ddPCR and NGS, and 0.03% with BEAMing. This high level of sensitivity enabled the detection of KRAS mutations in 5/19 CRC patients with negative FFPE profiles. In the mCRC cohort, comparison of mutation results obtained by testing FFPE to those obtained by testing cfDNA by ddPCR resulted in 47% sensitivity, 77% specificity, 70% positive predictive value (PPV) and 55% negative predictive value (NPV). For BEAMing, we observed 93% sensitivity, 69% specificity, 78% PPV and 90% NPV. Finally, sensitivity of NGS was 73%, specificity was 77%, PPV 79% and NPV 71%. Our study highlights the complementarity of different diagnostic approaches and variability of results between OncoBEAM™-RAS-CRC and NGS assays. While the NGS assay provided a larger breadth of coverage of the major targetable alterations of 56 genes in one run, its performance for specific alterations was frequently confirmed by ddPCR results. PMID:29765524
Adjorlolo, Samuel
2018-06-01
The sociocultural differences between Western and sub-Saharan African countries make it imperative to standardize neuropsychological tests in the latter. However, Western-normed tests are frequently administered in sub-Saharan Africa because of challenges hampering standardization efforts. Yet a salient topical issue in the cross-cultural neuropsychology literature relates to the utility of Western-normed neuropsychological tests in minority groups, non-Caucasians, and by extension Ghanaians. Consequently, this study investigates the diagnostic accuracy, sensitivity, and specificity of executive function (EF) tests (The Stroop Test, Trail Making Test, and Controlled Oral Word Association Test), and a Revised Quick Cognitive Screening Test (RQCST) in a sample of 50 patients diagnosed with moderate traumatic brain injury and 50 healthy controls in Ghana. The EF test scores showed good diagnostic accuracy, with area under the curve (AUC) values of the Trail Making Test scores ranging from .746 to .902. With respect to the Stroop Test scores, the AUC values ranged from .793 to .898, while Controlled Oral Word Association Test had AUC value of .787. The RQCST scores discriminated between the groups, with AUC values ranging from .674 to .912. The AUC values of composite EF score and a neuropsychological score created from EF and RQCST scores were .936 and. 942, respectively. Additionally, the Stroop Test, Trail Making Test, EF composite score, and RQCST scores showed good to excellent sensitivities and specificities. In general, this study has shown that commonly used EF tests in Western countries have diagnostic accuracy, sensitivity, and specificity when administered in Ghanaian samples. The findings and implications of the study are discussed.
Wang, Rui; Wang, Lei; Zhao, Haiyan; Jiang, Wei
2016-12-15
MicroRNAs (miRNAs) are vital for many biological processes and have been regarded as cancer biomarkers. Specific and sensitive detection of miRNAs is essential for cancer diagnosis and therapy. Herein, a split recognition mode combined with cascade signal amplification strategy is developed for highly specific and sensitive detection of miRNA. The split recognition mode possesses two specific recognition processes, which are based on toehold-mediated strand displacement reaction (TSDR) and direct hybridization reaction. Two recognition probes, hairpin probe (HP) with overhanging toehold domain and assistant probe (AP), are specially designed. Firstly, the toehold domain of HP and AP recognize part of miRNA simultaneously, accompanied with TSDR to unfold the HP and form the stable DNA Y-shaped junction structure (YJS). Then, the AP in YJS can further act as primer to initiate strand displacement amplification, releasing numerous trigger sequences. Finally, the trigger sequences hybridize with padlock DNA to initiate circular rolling circle amplification and generate enhanced fluorescence responses. In this strategy, the dual recognition effect of split recognition mode guarantees the excellent selectivity to discriminate let-7b from high-homology sequences. Furthermore, the high amplification efficiency of cascade signal amplification guarantees a high sensitivity with the detection limit of 3.2 pM and the concentration of let-7b in total RNA sample extracted from Hela cells is determined. These results indicate our strategy will be a promising miRNA detection strategy in clinical diagnosis and disease treatment. Copyright © 2016 Elsevier B.V. All rights reserved.
Koskinen, M T; Holopainen, J; Pyörälä, S; Bredbacka, P; Pitkälä, A; Barkema, H W; Bexiga, R; Roberson, J; Sølverød, L; Piccinini, R; Kelton, D; Lehmusto, H; Niskala, S; Salmikivi, L
2009-03-01
Intramammary infection (IMI), also known as mastitis, is the most frequently occurring and economically the most important infectious disease in dairy cattle. This study provides a validation of the analytical specificity and sensitivity of a real-time PCR-based assay that identifies 11 major pathogen species or species groups responsible for IMI, and a gene coding for staphylococcal beta-lactamase production (penicillin resistance). Altogether, 643 culture isolates originating from clinical bovine mastitis, human, and companion animal samples were analyzed using the assay. The isolates represented 83 different species, groups, or families, and originated from 6 countries in Europe and North America. The analytical specificity and sensitivity of the assay was 100% in bacterial and beta-lactamase identification across all isolates originating from bovine mastitis (n = 454). When considering the entire culture collection (including also the isolates originating from human and companion animal samples), 4 Streptococcus pyogenes, 1 Streptococcus salivarius, and 1 Streptococcus sanguis strain of human origin were identified as Streptococcus uberis, and 3 Shigella spp. strains were identified as Escherichia coli, decreasing specificity to 99% in Strep. uberis and to 99.5% in E. coli. These false-positive results were confirmed by sequencing of the 16S rRNA gene. Specificity and sensitivity remained at 100% for all other bacterial targets across the entire culture collection. In conclusion, the real-time PCR assay shows excellent analytical accuracy and holds much promise for use in routine bovine IMI testing programs. This study provides the basis for evaluating the assay's diagnostic performance against the conventional bacterial culture method in clinical field trials using mastitis milk samples.
Disler, D G; McCauley, T R; Kelman, C G; Fuchs, M D; Ratner, L M; Wirth, C R; Hospodar, P P
1996-07-01
The sensitivity of fat-suppressed three-dimensional spoiled gradient-echo (SPGR) images was compared with that of standard MR images for detecting hyaline cartilage defects of the knee, using arthroscopy as the standard of reference. We assessed 114 consecutive patients for hyaline cartilage defects of the knee with both standard MR imaging sequences and a sagittal fat-suppressed three-dimensional SPGR sequence. Of these patients, 48 with meniscal or ligament injury, or persistent symptoms, underwent subsequent arthroscopy. The standard MR images and SPGR images of these 48 patients were then retrospectively analyzed for articular defects in a blinded fashion by two independent observers. Sensitivity, specificity, and intraobserver and interobserver agreement were determined for the different imaging techniques. One fourth of the patients who went on to arthroscopy were shown to have isolated hyaline cartilage lesions that were clinically confused with meniscal tears and that were missed on the standard MR images. When looking at all surfaces combined for each reader, the SPGR imaging sequence had a significantly higher sensitivity than the standard MR imaging sequences for detecting hyaline cartilage defects (75-85% versus 29-38%, p < .001 for each comparison). When looking at individual surfaces for each reader, significant differences in sensitivity were shown for each surface except the trochlear and lateral tibial surfaces. We found no difference in specificity (97% versus 97%, p > .99). We also found that combined evaluation of standard MR and SPGR images gave no added diagnostic advantage (sensitivity, 86%; specificity, 97%; p > .42). Except for the lateral tibial surface, the study achieved excellent reproducibility among readings and between readers. Fat-suppressed three-dimensional SPGR imaging is more sensitive than standard MR imaging for the detection of hyaline cartilage defects of the knee.
Chen, Jinyang; Liu, Yucheng; Ji, Xinghu; He, Zhike
2016-09-15
In this work, a versatile dumbbell molecular (DM) probe was designed and employed in the sensitively homogeneous bioassay. In the presence of target molecule, the DM probe was protected from the digestion of exonucleases. Subsequently, the protected DM probe specifically bound to the intercalation dye and resulted in obvious fluorescence signal which was used to determine the target molecule in return. This design allows specific and versatile detection of diverse targets with easy operation and no sophisticated fluorescence labeling. Integrating the idea of target-protecting DM probe with adenosine triphosphate (ATP) involved ligation reaction, the DM probe with 5'-end phosphorylation was successfully constructed for ATP detection, and the limitation of detection was found to be 4.8 pM. Thanks to its excellent selectivity and sensitivity, this sensing strategy was used to detect ATP spiked in human serum as well as cellular ATP. Moreover, the proposed strategy was also applied in the visual detection of ATP in droplet-based microfluidic platform with satisfactory results. Similarly, combining the principle of target-protecting DM probe with streptavidin (SA)-biotin interaction, the DM probe with 3'-end biotinylation was developed for selective and sensitive SA determination, which demonstrated the robustness and versatility of this design. Copyright © 2016 Elsevier B.V. All rights reserved.
Yang, Zhongyi; Pan, Lingling; Cheng, Jingyi; Hu, Silong; Xu, Junyan; Ye, Dingwei; Zhang, Yingjian
2012-07-01
To investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity = 95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. © 2012 The Japanese Urological Association.
Cui, Shaohua; Zhang, Wei; Xiong, Liwen; Pan, Feng; Niu, Yanjie; Chu, Tianqing; Wang, Huimin; Zhao, Yizhuo; Jiang, Liyan
2017-01-10
Capture-based next-generation sequencing (NGS) is a potentially useful diagnostic method to measure tumor tissue DNA in blood as it can identify concordant mutations between cell-free DNA (cfDNA) and primary tumor DNA in lung cancer patients. In this study, the sensitivity, specificity and accuracy of capture-based NGS for detecting ALK fusion in plasma cfDNA was assessed. 24 patients with tissue ALK-positivity and 15 who did not harbor ALK fusion were enrolled. 13 ALK-positive samples were identified by capture-based NGS among the 24 samples with tissue ALK-positivity. In addition to EML4-ALK, 2 rare fusion types (FAM179A-ALK and COL25A1-ALK) were also identified. The overall sensitivity, specificity and accuracy for all cases were 54.2%, 100% and 71.8%, respectively. For patients without distant metastasis (M0-M1a) and patients with distant metastasis (M1b), the sensitivities were 28.6% and 64.7%, respectively. In the 15 patients who received crizotinib, the estimated median PFS was 9.93 months. Thus, captured-based NGS has acceptable sensitivity and excellent specificity for the detection of ALK fusion in plasma cfDNA, especially for patients with distant metastasis. This non-invasive method is clinically feasible for detecting ALK fusion in patients with advanced-stage NSCLC who cannot undergo traumatic examinations or have insufficient tissue samples for molecular tests.
Sai, Jin-Kan; Suyama, Masafumi; Kubokawa, Yoshihiro; Watanabe, Sumio
2008-02-28
To investigate the usefulness of secretin injection-MRCP for the diagnosis of mild chronic pancreatitis. Sixteen patients having mild chronic pancreatitis according to the Cambridge classification and 12 control subjects with no abnormal findings on the pancreatogram were examined for the diagnostic accuracy of secretin injection-MRCP regarding abnormal branch pancreatic ducts associated with mild chronic pancreatitis (Cambridge Classification), using endoscopic retrograde cholangiopancreatography (ERCP) for comparison. The sensitivity and specificity for abnormal branch pancreatic ducts determined by two reviewers were respectively 55%-63% and 75%-83% in the head, 57%-64% and 82%-83% in the body, and 44%-44% and 72%-76% in the tail of the pancreas. The sensitivity and specificity for mild chronic pancreatitis were 56%-63% and 92%-92%, respectively. Interobserver agreement (kappa statistics) concerning the diagnosis of an abnormal branch pancreatic duct and of mild chronic pancreatitis was good to excellent. Secretin injection-MRCP might be useful for the diagnosis of mild chronic pancreatitis.
Mitchell, Elizabeth O; Stewart, Greg; Bajzik, Olivier; Ferret, Mathieu; Bentsen, Christopher; Shriver, M Kathleen
2013-12-01
A multisite study was conducted to evaluate the performance of the Bio-Rad 4th generation GS HIV Combo Ag/Ab EIA versus Abbott 4th generation ARCHITECT HIV Ag/Ab Combo. The performance of two 3rd generation EIAs, Ortho Diagnostics Anti-HIV 1+2 EIA and Siemens HIV 1/O/2 was also evaluated. Study objective was comparison of analytical HIV-1 p24 antigen detection, sensitivity in HIV-1 seroconversion panels, specificity in blood donors and two HIV false reactive panels. Analytical sensitivity was evaluated with International HIV-1 p24 antigen standards, the AFFSAPS (pg/mL) and WHO 90/636 (IU/mL) standards; sensitivity in acute infection was compared on 55 seroconversion samples, and specificity was evaluated on 1000 negative blood donors and two false reactive panels. GS HIV Combo Ag/Ab demonstrated better analytical HIV antigen sensitivity compared to ARCHITECT HIV Ag/Ab Combo: 0.41 IU/mL versus 1.2 IU/mL (WHO) and 12.7 pg/mL versus 20.1 pg/mL (AFSSAPS); GS HIV Combo Ag/Ab EIA also demonstrated slightly better specificity compared to ARCHITECT HIV Ag/Ab Combo (100% versus 99.7%). The 4th generation HIV Combo tests detected seroconversion 7-11 days earlier than the 3rd generation HIV antibody only EIAs. Both 4th generation immunoassays demonstrated excellent performance in sensitivity, with the reduction of the serological window period (7-11 days earlier detection than the 3rd generation HIV tests). However, GS HIV Combo Ag/Ab demonstrated improved HIV antigen analytical sensitivity and slightly better specificity when compared to ARCHITECT HIV Ag/Ab Combo assay, with higher positive predictive values (PPV) for low prevalence populations. Copyright © 2013 Elsevier B.V. All rights reserved.
Sol-Gel Processing of MgF₂ Antireflective Coatings.
Löbmann, Peer
2018-05-02
There are different approaches for the preparation of porous antireflective λ/4 MgF₂ films from liquid precursors. Among these, the non-aqueous fluorolytic synthesis of precursor solutions offers many advantages in terms of processing simplicity and scalability. In this paper, the structural features and optical performance of the resulting films are highlighted, and their specific interactions with different inorganic substrates are discussed. Due to their excellent abrasion resistance, coatings have a high potential for applications on glass. Using solvothermal treatment of precursor solutions, also the processing of thermally sensitive polymer substrates becomes feasible.
Verginelli, Iason; Yao, Yijun; Suuberg, Eric M.
2017-01-01
In this study we present a petroleum vapor intrusion tool implemented in Microsoft® Excel® using Visual Basic for Applications (VBA) and integrated within a graphical interface. The latter helps users easily visualize two-dimensional soil gas concentration profiles and indoor concentrations as a function of site-specific conditions such as source strength and depth, biodegradation reaction rate constant, soil characteristics and building features. This tool is based on a two-dimensional explicit analytical model that combines steady-state diffusion-dominated vapor transport in a homogeneous soil with a piecewise first-order aerobic biodegradation model, in which rate is limited by oxygen availability. As recommended in the recently released United States Environmental Protection Agency's final Petroleum Vapor Intrusion guidance, a sensitivity analysis and a simplified Monte Carlo uncertainty analysis are also included in the spreadsheet. PMID:28163564
Verginelli, Iason; Yao, Yijun; Suuberg, Eric M
2016-01-01
In this study we present a petroleum vapor intrusion tool implemented in Microsoft ® Excel ® using Visual Basic for Applications (VBA) and integrated within a graphical interface. The latter helps users easily visualize two-dimensional soil gas concentration profiles and indoor concentrations as a function of site-specific conditions such as source strength and depth, biodegradation reaction rate constant, soil characteristics and building features. This tool is based on a two-dimensional explicit analytical model that combines steady-state diffusion-dominated vapor transport in a homogeneous soil with a piecewise first-order aerobic biodegradation model, in which rate is limited by oxygen availability. As recommended in the recently released United States Environmental Protection Agency's final Petroleum Vapor Intrusion guidance, a sensitivity analysis and a simplified Monte Carlo uncertainty analysis are also included in the spreadsheet.
Salivary hexosaminidase in smoking alcoholics with bad periodontal and dental states.
Waszkiewicz, Napoleon; Chojnowska, Sylwia; Zalewska, Anna; Zwierz, Krzysztof; Szulc, Agata; Szajda, Sławomir Dariusz
2013-04-01
A sensitive alcohol marker, β-hexosaminidase (HEX), in the saliva of alcoholics, is investigated for the first time. The activity, specific-activity and output of total HEX and its isoenzymes HEX A and HEX B were measured in the saliva of healthy controls (C), alcohol-dependent non-smokers (ANS), and alcohol-dependent smokers (AS). We observed a significantly increased activity/specific-activity and output of HEX A in the ANS and AS groups, due to the inflammatory state of the oral-cavity/salivary-glands. Significantly increased activity of HEX A contributed to an increase in the salivary activity of the total HEX in the ANS group. A significant decrease in the activity/specific-activity of HEX B in AS seemed to be due to HEX B inactivation by cigarette smoke. We noticed a tendency for deteriorated dental state (lower decayed-missing-filled-teeth index - DMFT), worse periodontal state (higher gingival index - GI and papilla-bleeding index - PBI) in AS, and worse periodontal state (higher GI) in ANS, as compared to the controls. We found no differences in the salivary protein concentrations between all groups and decreased salivary flow in both alcoholic groups as compared to the controls. In alcoholics, the area under the curve (AUC) for HEX A activity/specific-activity was significantly greater than for HEX and HEX B. The salivary HEX A activity/specific-activity had good/excellent sensitivity and specificity in smoking and non-smoking alcoholics, whereas salivary HEX and HEX B had poor/fair sensitivity and specificity. Salivary HEX A may be helpful in the diagnosis of chronic alcohol intoxication, even in smokers. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Comparison Of The Performance Of Hybrid Coders Under Different Configurations
NASA Astrophysics Data System (ADS)
Gunasekaran, S.; Raina J., P.
1983-10-01
Picture bandwidth reduction employing DPCM and Orthogonal Transform (OT) coding for TV transmission have been widely discussed in literature; both the techniques have their own advantages and limitations in terms of compression ratio, implementation, sensitivity to picture statistics and their sensitivity to the channel noise. Hybrid coding introduced by Habibi, - a cascade of the two techniques, offers excellent performance and proves to be attractive retaining the special advantages of both the techniques. In the recent times, the interest has shifted over to Hybrid coding, and in the absence of a report on the relative performance specifications of hybrid coders at different configurations, an attempt has been made to colate the information. Fourier, Hadamard, Slant, Sine, Cosine and Harr transforms have been considered for the present work.
Synthesis and characterization of hydrogen-bond acidic functionalized graphene
NASA Astrophysics Data System (ADS)
Yang, Liu; Han, Qiang; Pan, Yong; Cao, Shuya; Ding, Mingyu
2014-05-01
Hexafluoroisopropanol phenyl group functionalized materials have great potential in the application of gas-sensitive materials for nerve agent detection, due to the formation of strong hydrogen-bonding interactions between the group and the analytes. In this paper, take full advantage of ultra-large specific surface area and plenty of carbon-carbon double bonds and hexafluoroisopropanol phenyl functionalized graphene was synthesized through in situ diazonium reaction between -C=C- and p-hexafluoroisopropanol aniline. The identity of the as-synthesis material was confirmed by transmission electron microscopy, Raman spectroscopy, ultraviolet visible spectroscopy, X-ray photoelectron spectroscopy and thermo gravimetric analysis. The synthesis method is simply which retained the excellent physical properties of original graphene. In addition, the novel material can be assigned as an potential candidate for gas sensitive materials towards organophosphorus nerve agent detection.
Poran, S.; Nguyen-Duc, T.; Auerbach, A.; Dupuis, N.; Frydman, A.; Bourgeois, Olivier
2017-01-01
The superconductor–insulator transition (SIT) is considered an excellent example of a quantum phase transition that is driven by quantum fluctuations at zero temperature. The quantum critical point is characterized by a diverging correlation length and a vanishing energy scale. Low-energy fluctuations near quantum criticality may be experimentally detected by specific heat, cp, measurements. Here we use a unique highly sensitive experiment to measure cp of two-dimensional granular Pb films through the SIT. The specific heat shows the usual jump at the mean field superconducting transition temperature marking the onset of Cooper pairs formation. As the film thickness is tuned towards the SIT, is relatively unchanged, while the magnitude of the jump and low-temperature specific heat increase significantly. This behaviour is taken as the thermodynamic fingerprint of quantum criticality in the vicinity of a quantum phase transition. PMID:28224994
Poran, S; Nguyen-Duc, T; Auerbach, A; Dupuis, N; Frydman, A; Bourgeois, Olivier
2017-02-22
The superconductor-insulator transition (SIT) is considered an excellent example of a quantum phase transition that is driven by quantum fluctuations at zero temperature. The quantum critical point is characterized by a diverging correlation length and a vanishing energy scale. Low-energy fluctuations near quantum criticality may be experimentally detected by specific heat, c p , measurements. Here we use a unique highly sensitive experiment to measure c p of two-dimensional granular Pb films through the SIT. The specific heat shows the usual jump at the mean field superconducting transition temperature marking the onset of Cooper pairs formation. As the film thickness is tuned towards the SIT, is relatively unchanged, while the magnitude of the jump and low-temperature specific heat increase significantly. This behaviour is taken as the thermodynamic fingerprint of quantum criticality in the vicinity of a quantum phase transition.
Gibbons-Burgener, S N; Kaneene, J B; Lloyd, J W; Leykam, J F; Erskine, R J
2001-11-01
To determine the likelihood of false-positive results when testing milk samples from individual cows by use of 3 commercially available assays (Penzyme MilkTest and the SNAP beta-lactam and Delvo-SP assays) labeled for use with commingled milk. Milk samples from 111 cows with mild clinical mastitis. Cows were randomly assigned to the control (no antimicrobials) or intramammary treatment group. Posttreatment milk samples were collected at the first milking after the labeled withholding period or an equivalent time for controls, randomly ordered, and tested twice by use of each assay and once by use of high-performance liquid chromatography. Sensitivity, specificity, and positive and negative predictive values were determined for each assay. Concordance of results for the same sample was assessed for each assay by calculating kappa. Sensitivities of the Delvo-SP and SNAP lactam assays were > 90%, whereas the sensitivity of the Penzyme Milk Test was 60%. Positive predictive values (range, 39.29 to 73.68%) were poor for all 3 assays. Concordance of test results was excellent for the SNAP beta-lactam and Delvo-SP assays (kappa = 0.846 and 0.813, respectively) but was less for the Penzyme MilkTest (kappa = 0.545). Because of the low positive predictive values, these 3 assays may not be useful for detecting violative antimicrobial residues in individual milk samples from cows treated for mild clinical mastitis. However, repeatability of each assay was considered good to excellent.
GATE simulation of a new design of pinhole SPECT system for small animal brain imaging
NASA Astrophysics Data System (ADS)
Uzun Ozsahin, D.; Bläckberg, L.; El Fakhri, G.; Sabet, H.
2017-01-01
Small animal SPECT imaging has gained an increased interest over the past decade since it is an excellent tool for developing new drugs and tracers. Therefore, there is a huge effort on the development of cost-effective SPECT detectors with high capabilities. The aim of this study is to simulate the performance characteristics of new designs for a cost effective, stationary SPECT system dedicated to small animal imaging with a focus on mice brain. The conceptual design of this SPECT system platform, Stationary Small Animal SSA-SPECT, is to use many pixelated CsI:TI detector modules with 0.4 mm × 0.4 mm pixels in order to achieve excellent intrinsic detector resolution where each module is backed by a single pinhole collimator with 0.3 mm hole diameter. In this work, we present the simulation results of four variations of the SSA-SPECT platform where the number of detector modules and FOV size is varied while keeping the detector size and collimator hole size constant. Using the NEMA NU-4 protocol, we performed spatial resolution, sensitivity, image quality simulations followed by a Derenzo-like phantom evaluation. The results suggest that all four SSA-SPECT systems can provide better than 0.063% system sensitivity and < 1.5 mm FWHM spatial resolution without resolution recovery or other correction techniques. Specifically, SSA-SPECT-1 showed a system sensitivity of 0.09% in combination with 1.1 mm FWHM spatial resolution.
Liu, Lijuan; Xie, Yuling; Dai, Zhenxian; Zhuo, Chuanshang; Wu, Yushui
2015-11-01
The serological detection of specific antibodies against Treponema pallidum is of particular importance in the diagnosis of syphilis. The chemiluminescence immunoassay (CLIA) has been widely used for clinical diagnosis because they remit no radical waste products, cause no enzyme precipitation, and exhibit an excellent sensitivity. A one-step CLIA was established to detect T. pallidum IgG antibody based on microplate coated with a mixture of recombinant T. pallidum antigens TpN15, TpN17, and TpN47. The Chinese national reference substances standard panel for T. pallidum diagnosis was applied to test the accuracy, stability, interference, and cross-reactivity of the established CLIA. The validation of efficacy for clinical application was performed by comparing the established method with the marketed T. pallidum particle agglutination (TPPA) kit and the Abbott ARCHITEC Auto System. The established method met the requirement of the Chinese national reference substances standard for T. pallidum diagnosis. When compared with TPPA (n = 1,052), the specificity, sensitivity, and overall concordance were 99.7%, 99.0%, and 98.8% respectively, showing a great agreement with a kappa value of 0.81. When compared with the Abbott ARCHITEC Auto System (n = 352), the results showed that the specificity, sensitivity, and overall concordance were 98.6.0%, 96.6% and 98.6% respectively, and a high-degree agreement was observed (kappa value = 0.95). The established rapid, specific, sensitive, and stable microplate CLIA method to detect IgG antibody against T pallidum will provide an efficient alternative to the treponemal tests and wide application in clinical laboratory. © 2014 Wiley Periodicals, Inc.
Udo, Tomoko; McKee, Sherry A; Grilo, Carlos M
2015-01-01
The Beck Depression Inventory (BDI) is often used to assess depression symptoms, but its factor structure and its clinical utility have not been evaluated in patients with binge eating disorder (BED) and obesity. A total of 882 treatment-seeking obese patients with BED were administered structured interviews (Structured Clinical Interview for Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition Axis I Disorders) and completed self-report questionnaires. Exploratory and confirmatory factor analyses supported a brief 16-item BDI version with a three-factor structure (affective, attitudinal and somatic). Both 21- and 16-item versions showed excellent internal consistency (both α=0.89) and had significant correlation patterns with different aspects of eating disorder psychopathology; three factors showed significant but variable associations with eating disorder psychopathology. Area under the curves (AUC) for both BDI versions were significant in predicting major depressive disorder (MDD; AUC=0.773 [16-item], 73.5% sensitivity/70.2% specificity, AUC=0.769 [21-item], 79.5% sensitivity/64.1% specificity) and mood disorders (AUC=0.763 [16-item], 67.1% sensitivity/71.5% specificity, AUC=0.769 [21-item], 84.2% sensitivity/55.7% specificity). The 21-item BDI (cutoff score ≥16) showed higher negative predictive values (94.0% vs. 93.0% [MDD]; 92.4% vs. 88.3% [mood disorders]) than the brief 16-item BDI (cutoff score ≥13). Both BDI versions demonstrated moderate performance as a screening instrument for MDD/mood disorders in obese patients with BED. Advantages and disadvantages for both versions are discussed. A three-factor structure has potential to inform the conceptualization of depression features. Copyright © 2015 Elsevier Inc. All rights reserved.
Naeger, D M; Chang, S D; Kolli, P; Shah, V; Huang, W; Thoeni, R F
2011-01-01
Objective The study compared the sensitivity, specificity, confidence and interpretation time of readers of differing experience in diagnosing acute appendicitis with contrast-enhanced CT using neutral vs positive oral contrast agents. Methods Contrast-enhanced CT for right lower quadrant or right flank pain was performed in 200 patients with neutral and 200 with positive oral contrast including 199 with proven acute appendicitis and 201 with other diagnoses. Test set disease prevalence was 50%. Two experienced gastrointestinal radiologists, one fellow and two first-year residents blindly assessed all studies for appendicitis (2000 readings) and assigned confidence scores (1=poor to 4=excellent). Receiver operating characteristic (ROC) curves were generated. Total interpretation time was recorded. Each reader's interpretation with the two agents was compared using standard statistical methods. Results Average reader sensitivity was found to be 96% (range 91–99%) with positive and 95% (89–98%) with neutral oral contrast; specificity was 96% (92–98%) and 94% (90–97%). For each reader, no statistically significant difference was found between the two agents (sensitivities p-values >0.6; specificities p-values>0.08), in the area under the ROC curve (range 0.95–0.99) or in average interpretation times. In cases without appendicitis, positive oral contrast demonstrated improved appendix identification (average 90% vs 78%) and higher confidence scores for three readers. Average interpretation times showed no statistically significant differences between the agents. Conclusion Neutral vs positive oral contrast does not affect the accuracy of contrast-enhanced CT for diagnosing acute appendicitis. Although positive oral contrast might help to identify normal appendices, we continue to use neutral oral contrast given its other potential benefits. PMID:20959365
Müller, U; Schmid-Grendelmeier, P; Hausmann, O; Helbling, A
2012-08-01
Diagnostic tests in patients with Hymenoptera venom allergy are frequently positive to venoms of both honey bee and wasp (Vespula). Component-resolved analysis with recombinant species-specific major allergens (rSSMA) may help to distinguish true double sensitization from crossreactivity. Included were 121 patients with systemic allergic reactions to Hymenoptera stings, 76 with double positivity of serum-specific IgE (sIgE) to both venoms, 45 with single positivity to bee or wasp venom, and 32 controls without history of systemic reactions to Hymenoptera stings and no sIgE to whole venoms. In venom-allergic patients and controls, sIgE to rSSMA Api m 1 of bee venom and to Ves v 1 and Ves v 5 of wasp venom were tested by ImmunoCAP. Only 47% of 76 patients with double positivity to whole venoms reacted also to rSSMA of both species. Specificity of sIgE to the 3 rSSMA was very high, with no sIgE to rSSMA of the other species in single-positive venom-allergic patients and only one control with low sIgE to Ves v 1. All wasp-allergic single-positive patients had sIgE to Ves v 5 and/or Ves v 1, and 78.3% of single-positive bee venom-allergic patients had sIgE to Api m 1. Specificity of sIgE to rSSMA of both species is excellent. Sensitivity of sIgE to rSSMA was optimal for wasp venom. Sensitivity of bee venom Api m 1 could be increased by adding rSSMA of other important bee venom allergens. © 2012 John Wiley & Sons A/S.
Wang, Guorong; Guo, Ling; Jiang, Bin; Huang, Min; Zhang, Jian; Qin, Ying
2015-01-01
Amplitude changes in the P-wave of intracavitary electrocardiography have been used to assess the tip placement of central venous catheters. The research assessed the sensitivity and specificity of this sign in comparison with standard radiographic techniques for tip location, focusing on factors influencing its clinical utility. Both intracavitary electrocardiography guided tip location and X-ray positioning were used to verify catheter tip locations in patients undergoing central venous catheter insertion. Intracavitary electrocardiograms from 1119 patients (of a total 1160 subjects) showed specific amplitude changes in the P-wave. As the results show, compared with X-ray positioning, the sensitivity of electrocardiography-guided tip location was 97.3%, with false negative rate of 2.7%; the specificity was 1, with false positive rate of zero. Univariate analyses indicated that features including age, gender, height, body weight, and heart rate have no statistically significant influence on P-wave amplitude changes (P>0.05). Multivariate logistic regression revealed that catheter insertion routes (OR = 2.280, P = 0.003) and basal P-wave amplitude (OR = 0.553, P = 0.003) have statistically significant impacts on P-wave amplitude changes. As a reliable indicator of tip location, amplitude change in the P-wave has proved of good sensitivity and excellent specificity, and the minor, zero, false positive rate supports the clinical utility of this technique in early recognition of malpositioned tips. A better sensitivity was achieved in placement of centrally inserted central catheters (CICCs) than that of peripherally inserted central catheters (PICCs). In clinical practice, a combination of intracavitary electrocardiography, ultrasonic inspection and the anthropometric measurement method would further improve the accuracy. PMID:25915758
Kao, Hua-Lin; Yeh, Yi-Chen; Lin, Chin-Hsuan; Hsu, Wei-Fang; Hsieh, Wen-Yu; Ho, Hsiang-Ling; Chou, Teh-Ying
2016-11-01
Analysis of the targetable driver mutations is now recommended in all patients with advanced lung adenocarcinoma. Molecular-based methods are usually adopted, however, along with the implementation of highly sensitive and/or mutation-specific antibodies, immunohistochemistry (IHC) has been considered an alternative method for identifying driver mutations in lung adenocarcinomas. A total of 205 lung adenocarcinomas were examined for EGFR mutations and ALK and ROS1 rearrangements using real-time PCR, fluorescence in situ hybridization (FISH) and IHC in parallel. The performance of different commercially available IHC antibody clones toward targetable driver mutations was evaluated. The association between these driver mutations and clinicopathological characteristics was also analyzed. In 205 cases we studied, 58.5% were found to harbor EGFR mutations, 6.3% ALK rearrangements and 1.0% ROS1 rearrangements. Compared to molecular-based methods, IHC of EGFR mutations showed an excellent specificity but the sensitivity is suboptimal, while IHC of ALK and ROS1 rearrangements demonstrated high sensitivity and specificity. No significant difference regarding the performance of different antibody clones toward these driver mutations was observed, except that clone SP125 showed a higher sensitivity than 43B2 in the detection of p.L858R of EGFR. In circumstances such as poor quality of nucleic acids or low content of tumor cells, IHC of EGFR mutation-specific antibodies could be used as an alternative method. Patients negative for EGFR mutations are subjected to further analysis on ALK and ROS1 rearrangements using IHC methods. Herein, we proposed a lung adenocarcinoma testing algorithm for the application of IHC in therapeutic diagnosis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Putsathit, Papanin; Morgan, Justin; Bradford, Damien; Engelhardt, Nelly; Riley, Thomas V
2015-02-01
The Becton Dickinson (BD) PCR-based GeneOhm Cdiff assay has demonstrated a high sensitivity and specificity for detecting Clostridium difficile. Recently, the BD Max platform, using the same principles as BD GeneOhm, has become available in Australia. This study aimed to investigate the sensitivity and specificity of BD Max Cdiff assay for the detection of toxigenic C. difficile in an Australian setting. Between December 2013 and January 2014, 406 stool specimens from 349 patients were analysed with the BD Max Cdiff assay. Direct and enrichment toxigenic culture were performed on bioMérieux ChromID C. difficile agar as a reference method. isolates from specimens with discrepant results were further analysed with an in-house PCR to detect the presence of toxin genes. The overall prevalence of toxigenic C. difficile was 7.2%. Concordance between the BD Max assay and enrichment culture was 98.5%. The sensitivity, specificity, positive predictive value and negative predictive value for the BD Max Cdiff assay were 95.5%, 99.0%, 87.5% and 99.7%, respectively, when compared to direct culture, and 91.7%, 99.0%, 88.0% and 99.4%, respectively, when compared to enrichment culture. The new BD Max Cdiff assay appeared to be an excellent platform for rapid and accurate detection of toxigenic C. difficile.
Kinoshita, Kensuke; Hattori, Kazuya; Ota, Yoshio; Kanai, Takao; Shimizu, Miyuki; Kobayashi, Hiroyuki; Tokuda, Yasuharu
2013-02-01
Dry axilla can sometimes be found among dehydrated older patients. In this study, we measured the axillary moisture and assessed it as possible marker for dehydration. Twenty-nine older patients admitted with acute medical conditions participated in this study. Dehydration was diagnosed by the calculated serum osmolality of greater than 295 mOsm/L. The moisture of axilla was measured by a skin moisture impedance meter which was applied at the center of axilla of patients. 11 patients (7 males and 4 females) were diagnosed as dehydrated and 18 patients (10 males and 8 females) were diagnosed as non-dehydrated. The mean axillary moisture (33%) in the dehydrated group was significantly lower than that (42%) in the non-dehydrated group (p<0.05). The axillary moisture ≥50% showed the sensitivity of 88%. The axillary moisture <30% showed the specificity of 91%. Use of a single cutoff value of 40% moisture produced the sensitivity of 59% and the specificity of 9%. As for the physical signs, dry axilla had also moderate sensitivity and excellent specificity to detect dehydration. The measurement of the axillary moisture could help assess dehydration. Dehydration could be ruled out when the axillary moisture ≥50%, while it could be ruled-in when the axillary moisture is <30%. Copyright © 2012 Elsevier Inc. All rights reserved.
Walls, Brittany D; Wallace, Elizabeth R; Brothers, Stacey L; Berry, David T R
2017-12-01
Recent concern about malingered self-report of symptoms of attention-deficit hyperactivity disorder (ADHD) in college students has resulted in an urgent need for scales that can detect feigning of this disorder. The present study provided further validation data for a recently developed validity scale for the Conners' Adult ADHD Rating Scale (CAARS), the CAARS Infrequency Index (CII), as well as for the Inconsistency Index (INC). The sample included 139 undergraduate students: 21 individuals with diagnoses of ADHD, 29 individuals responding honestly, 54 individuals responding randomly (full or half), and 35 individuals instructed to feign. Overall, the INC showed moderate sensitivity to random responding (.44-.63) and fairly high specificity to ADHD (.86-.91). The CII demonstrated modest sensitivity to feigning (.31-.46) and excellent specificity to ADHD (.91-.95). Sequential application of validity scales had correct classification rates of honest (93.1%), ADHD (81.0%), feigning (57.1%), half random (42.3%), and full random (92.9%). The present study suggests that the CII is modestly sensitive (true positive rate) to feigned ADHD symptoms, and highly specific (true negative rate) to ADHD. Additionally, this study highlights the utility of applying the CAARS validity scales in a sequential manner for identifying feigning. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Gweon, Hye Mi; Youk, Ji Hyun; Son, Eun Ju; Kim, Jeong-Ah
2013-03-01
To determine whether colour overlay features can be quantified by the standard deviation (SD) of the elasticity measured in shear-wave elastography (SWE) and to evaluate the diagnostic performance for breast masses. One hundred thirty-three breast lesions in 119 consecutive women who underwent SWE before US-guided core needle biopsy or surgical excision were analysed. SWE colour overlay features were assessed using two different colour overlay pattern classifications. Quantitative SD of the elasticity value was measured with the region of interest including the whole breast lesion. For the four-colour overlay pattern, the area under the ROC curve (Az) was 0.947; with a cutoff point between pattern 2 and 3, sensitivity and specificity were 94.4 % and 81.4 %. According to the homogeneity of the elasticity, the Az was 0.887; with a cutoff point between reasonably homogeneous and heterogeneous, sensitivity and specificity were 86.1 % and 82.5 %. For the SD of the elasticity, the Az was 0.944; with a cutoff point of 12.1, sensitivity and specificity were 88.9 % and 89.7 %. The colour overlay features showed significant correlations with the quantitative SD of the elasticity (P < 0.001). The colour overlay features and the SD of the elasticity in SWE showed excellent diagnostic performance and showed good correlations between them.
Gong, Tao; Liu, Yubo; Wang, Guangbin; Yang, Li; Chen, Weibo; Gao, Fei; Chen, Xin
2016-11-01
The purpose of this study was to determine the added value of the perimedullary spinal vein enlargement sign on magnetic resonance imaging (MRI) in distinguishing intradural-extramedullary tumors (IDEMTs) from intramedullary spinal tumors (IMTs). Two hundred and eight consecutive spinal intradural tumors with histopathologic confirmation (21 IMTs, 187 IDEMTs) were enrolled. Two readers blinded to the final pathological diagnosis and clinical data independently assessed the venous enlargement sign to determine the agreement between them and jointly distinguished IDEMTs from IMTs according to the common MRI findings. Sensitivity, specificity, and accuracy for the diagnosis of IDEMTs were calculated for the common MRI findings, vein enlargement sign, and a combination of both. Intraobserver agreement and interobserver agreement for both readers was excellent. The sensitivity, specificity, and accuracy of common MRI findings for differentiating IDEMTs from IMTs were 83.4, 95.2, and 89.3 %, respectively. Thirty-one IDEMTs were mistakenly diagnosed as IMTs, in which seven were cases with vein enlargement signs. By applying the vein enlargement sign to the common MRI findings, the specificity remained at 95.2 %, while the sensitivity improved to 89.3 % and the accuracy increased to 92.3 %. The spinal perimedullary vein enlargement sign is useful in assessing intradural tumors and to differentiate IDEMTs from IMTs.
NASA Astrophysics Data System (ADS)
Xu, Xiaobin; Liu, Yangqian; Gao, Fuyu; Song, Ningfang
2018-07-01
Hollow-core photonic bandgap fibers (HC-PBFs) are suitable for spaceborne fiber optical gyroscopes owing to their excellent environmental adaptability. However, hundreds of small holes full of air at one atmosphere of pressure can make the HC-PBF sensitive to external atmospheric pressure. In this study, we investigated the phase sensitivity of the fundamental mode to external atmospheric pressure for the HC-PBF, and the experimental result indicates that the phase sensitivity is approximately 1.6 × 10-5 ppm/Pa, which is mostly contributed by the change in the pressure-induced length. Through the choice of coating, the phase sensitivity to external atmospheric pressure can be reduced by about a factor of five compared to current HC-PBFs, and the excellent temperature performance can be maintained at the same time.
de Vente, Wieke; Majdandžić, Mirjana; Voncken, Marisol J; Beidel, Deborah C; Bögels, Susan M
2014-03-01
We developed a new version of the Social Phobia and Anxiety Inventory (SPAI) in order to have a brief instrument for measuring social anxiety and social anxiety disorder (SAD) with a strong conceptual foundation. In the construction phase, a set of items representing 5 core aspects of social anxiety was selected by a panel of social anxiety experts. The selected item pool was validated using factor analysis, reliability analysis, and diagnostic analysis in a sample of healthy participants (N = 188) and a sample of clinically referred participants diagnosed with SAD (N = 98). This procedure resulted in an abbreviated version of the Social Phobia Subscale of the SPAI consisting of 18 items (i.e. the SPAI-18), which correlated strongly with the Social Phobia Subscale of the original SPAI (both groups r = .98). Internal consistency and diagnostic characteristics using a clinical cut-off score > 48 were good to excellent (Cronbach's alpha healthy group = .93; patient group = .91; sensitivity: .94; specificity: .88). The SPAI-18 was further validated in a community sample of parents-to-be without SAD (N = 237) and with SAD (N = 65). Internal consistency was again excellent (both groups Cronbach's alpha = .93) and a screening cut-off of > 36 proved to result in good sensitivity and specificity. The SPAI-18 also correlated strongly with other social anxiety instruments, supporting convergent validity. In sum, the SPAI-18 is a psychometrically sound instrument with good screening capacity for social anxiety disorder in clinical as well as community samples. Copyright © 2013 Elsevier Ltd. All rights reserved.
Fish scale artefact on an intraoral imaging receptor.
Buchanan, Allison; Morales, Carla; Looney, Stephen; Kalathingal, Sajitha
2017-12-01
To describe an artefact, termed the fish scale artefact, present on an intraoral imaging receptor. Thirty brand new DIGORA Optime photostimulable phosphor (PSP) plates (Soredex/Orion Corp., Helsinki, Finland) were imaged using the dental digital quality assurance radiographic phantom (Dental Imaging Consultants LLC, San Antonio, TX). All PSP plates were scanned at the same spatial resolution (dpi) using the high resolution mode. Two evaluators assessed all 30 plates. Each evaluator assessed the 30 PSP plates separately for purposes of establishing interrater reliability, and then together in order to obtain the gold standard result. The fish scale artefact was detected on 46.7% of the PSP plates. The kappa coefficient for interrater reliability was 0.86 [95% CI (0.69-1.00)], indicating excellent interrater reliability. For Evaluator 1, sensitivity was 0.85 [95% CI (0.55-0.98)]; specificity was 0.94 [CI (0.71-1.00)] and overall accuracy was 0.90 [95% CI (0.73-0.98)]. For Evaluator 2, sensitivity was 1.00 [95% CI (0.75-1.00)]; specificity was 0.94 [CI (0.71-1.00)] and overall accuracy was 0.97 [95% CI (0.83-1.00)]. These results indicate excellent agreement with the gold standard for both evaluators. Utilizing a comprehensive quality assurance protocol, we identified a fish scale artefact inherent to the image receptor. Additional research is needed to determine if the artefact remains static over time or if it increases over time. Likewise, research to determine the potential sources contributing to an increase in the artefact is needed.
Validation of Nutritional Risk Screening-2002 in a Hospitalized Adult Population.
Bolayir, Başak; Arik, Güneş; Yeşil, Yusuf; Kuyumcu, Mehmet Emin; Varan, Hacer Doğan; Kara, Özgür; Güngör, Anil Evrim; Yavuz, Burcu Balam; Cankurtaran, Mustafa; Halil, Meltem Gülhan
2018-03-30
Malnutrition in hospitalized patients is a serious problem and is associated with a number of adverse outcomes. The Nutritional Risk Screening-2002 (NRS-2002) tool was designed to identify patients at nutrition risk. The validation of NRS-2002 compared with detailed clinical assessment of nutrition status was not studied before in hospitalized Turkish adults. The aim of this study is to determine validity, sensitivity, and specificity of the Turkish version of NRS-2002 in a hospitalized adult population. A total of 271 consecutive hospitalized patients aged >18 years admitted to surgical and medical wards of a university hospital in Turkey were included in this single-center non interventional validity study. Assessment by geriatricians was used as the reference method. Two geriatricians experienced in the field of malnutrition interpreted the patients' nutrition status after the evaluation of several parameters. Patients were divided into "at nutrition risk" and "not at nutrition risk" groups by geriatricians. Concordance between the 2 geriatricians' clinical assessments was analyzed by κ statistics. Excellent concordance was found; therefore, the first geriatrician's decisions were accepted as the gold standard. The correlation of nutrition status of the patients, determined with NRS-2002 and experienced geriatrician's decisions, was evaluated for the validity. NRS-2002 has a sensitivity of 88% and specificity of 92% when compared with professional assessment. The positive and negative predictive values were 87% and 92%, respectively. Testretest agreement was excellent as represented by a κ coefficient of 0.956. NRS-2002 is a valid tool to assess malnutrition risk in Turkish hospitalized patients. © 2018 American Society for Parenteral and Enteral Nutrition.
Lalji, U C; Houben, I P L; Prevos, R; Gommers, S; van Goethem, M; Vanwetswinkel, S; Pijnappel, R; Steeman, R; Frotscher, C; Mok, W; Nelemans, P; Smidt, M L; Beets-Tan, R G; Wildberger, J E; Lobbes, M B I
2016-12-01
Contrast-enhanced spectral mammography (CESM) is a promising problem-solving tool in women referred from a breast cancer screening program. We aimed to study the validity of preliminary results of CESM using a larger panel of radiologists with different levels of CESM experience. All women referred from the Dutch breast cancer screening program were eligible for CESM. 199 consecutive cases were viewed by ten radiologists. Four had extensive CESM experience, three had no CESM experience but were experienced breast radiologists, and three were residents. All readers provided a BI-RADS score for the low-energy CESM images first, after which the score could be adjusted when viewing the entire CESM exam. BI-RADS 1-3 were considered benign and BI-RADS 4-5 malignant. With this cutoff, we calculated sensitivity, specificity and area under the ROC curve. CESM increased diagnostic accuracy in all readers. The performance for all readers using CESM was: sensitivity 96.9 % (+3.9 %), specificity 69.7 % (+33.8 %) and area under the ROC curve 0.833 (+0.188). CESM is superior to conventional mammography, with excellent problem-solving capabilities in women referred from the breast cancer screening program. Previous results were confirmed even in a larger panel of readers with varying CESM experience. • CESM is consistently superior to conventional mammography • CESM increases diagnostic accuracy regardless of a reader's experience • CESM is an excellent problem-solving tool in recalls from screening programs.
Musher, Benjamin; Fredricks, David; Leisenring, Wendy; Balajee, S. Arunmozhi; Smith, Caitlin; Marr, Kieren A.
2004-01-01
Invasive pulmonary aspergillosis (IPA) is frequent and often fatal in hematopoietic stem cell transplant patients. Diagnosis requires microbiological or histopathologic demonstration of the organism in tissues; however, cultivation of Aspergillus species from respiratory secretions has low diagnostic sensitivity. Assays to detect Aspergillus antigen or DNA in bronchoalveolar lavage (BAL) fluid could facilitate earlier diagnosis, thereby guiding optimal therapy and obviating the need for additional costly and potentially morbid diagnostic evaluation. We evaluated the performance of a galactomannan enzyme immunoassay (GM EIA; Bio-Rad) by using a range of index cutoffs to define positivity and a quantitative PCR (qPCR) assay for the detection of Aspergillus species from BAL samples of patients with proven and probable IPA (case patients; n = 49) and without IPA (control patients; n = 50). The sensitivity of the GM EIA was 61% with an index cutoff of 1.0 and 76% with an index cutoff of 0.5; the corresponding specificities were 98 and 94%, respectively. The sensitivity and specificity of qPCR assay were 67 and 100%, respectively. The sensitivity with 22 culture-negative BAL specimens from patients with IPA was 41% for GM EIA with an index cutoff of 1.0, 59% for GM EIA with an index cutoff of 0.5, and 36% for qPCR assay. GM EIA indices and DNA quantities corresponded to BAL fungal burdens, with culture-positive samples having larger amounts of antigen and DNA compared to culture-negative samples. GM EIA and qPCR assay add to the sensitivity of BAL for diagnosing IPA in high-risk patients, with excellent specificity. Adjunctive use of these tests may reduce dependence on invasive diagnostic procedures. PMID:15583275
Blood DNA methylation biomarkers predict clinical reactivity in food-sensitized infants.
Martino, David; Dang, Thanh; Sexton-Oates, Alexandra; Prescott, Susan; Tang, Mimi L K; Dharmage, Shyamali; Gurrin, Lyle; Koplin, Jennifer; Ponsonby, Anne-Louise; Allen, Katrina J; Saffery, Richard
2015-05-01
The diagnosis of food allergy (FA) can be challenging because approximately half of food-sensitized patients are asymptomatic. Current diagnostic tests are excellent makers of sensitization but poor predictors of clinical reactivity. Thus oral food challenges (OFCs) are required to determine a patient's risk of reactivity. We sought to discover genomic biomarkers of clinical FA with utility for predicting food challenge outcomes. Genome-wide DNA methylation (DNAm) profiling was performed on blood mononuclear cells from volunteers who had undergone objective OFCs, concurrent skin prick tests, and specific IgE tests. Fifty-eight food-sensitized patients (aged 11-15 months) were assessed, half of whom were clinically reactive. Thirteen nonallergic control subjects were also assessed. Reproducibility was assessed in an additional 48 samples by using methylation data from an independent population of patients with clinical FA. Using a supervised learning approach, we discovered a DNAm signature of 96 CpG sites that predict clinical outcomes. Diagnostic scores were derived from these 96 methylation sites, and cutoffs were determined in a sensitivity analysis. Methylation biomarkers outperformed allergen-specific IgE and skin prick tests for predicting OFC outcomes. FA status was correctly predicted in the replication cohort with an accuracy of 79.2%. DNAm biomarkers with clinical utility for predicting food challenge outcomes are readily detectable in blood. The development of this technology in detailed follow-up studies will yield highly innovative diagnostic assays. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Jones, Alvin
2016-05-01
This research examined cutoff scores for the Effort Index (EI), an embedded measure of performance validity, for the Repeatable Battery for the Assessment of Neuropsychological Status. EI cutoffs were explored for an active-duty military sample composed mostly of patients with traumatic brain injury. Four psychometrically defined malingering groups including a definite malingering, probable to definite malingering, probable malingering, and a combined group were formed based on the number of validity tests failed. Excellent specificities (0.97 or greater) were found for all cutoffs examined (EI ≥ 1 to EI ≥ 3). Excellent sensitivities (0.80 to 0.89) were also found for the definite malingering group. Sensitivities were 0.49 or below for the other groups. Positive and negative predictive values and likelihood ratios indicated that the cutoffs for EI were much stronger for ruling-in than ruling-out malingering. Analyses indicated the validity tests used to form the malingering groups were uncorrelated, which serves to enhance the validity of the formation of the malingering groups. Cutoffs were similar to other research using samples composed predominantly of head-injured individuals. Published by Oxford University Press 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Fu, Lawrence D; Aphinyanaphongs, Yindalon; Wang, Lily; Aliferis, Constantin F
2011-08-01
Evaluating the biomedical literature and health-related websites for quality are challenging information retrieval tasks. Current commonly used methods include impact factor for journals, PubMed's clinical query filters and machine learning-based filter models for articles, and PageRank for websites. Previous work has focused on the average performance of these methods without considering the topic, and it is unknown how performance varies for specific topics or focused searches. Clinicians, researchers, and users should be aware when expected performance is not achieved for specific topics. The present work analyzes the behavior of these methods for a variety of topics. Impact factor, clinical query filters, and PageRank vary widely across different topics while a topic-specific impact factor and machine learning-based filter models are more stable. The results demonstrate that a method may perform excellently on average but struggle when used on a number of narrower topics. Topic-adjusted metrics and other topic robust methods have an advantage in such situations. Users of traditional topic-sensitive metrics should be aware of their limitations. Copyright © 2011 Elsevier Inc. All rights reserved.
A rapid immunochromatographic test strip for detecting rabies virus antibody.
Wang, Hualei; Feng, Na; Yang, Songtao; Wang, Chengyu; Wang, Tiecheng; Gao, Yuwei; Su, Jianqing; Zheng, Xuexing; Hou, Xiaoqiang; Huang, Hainan; Yang, Ruimei; Zou, Xiaohuan; Huang, Geng; Xia, Xianzhu
2010-12-01
An immunochromatographic test strip (ICTS) for detecting antibodies to rabies virus was developed, using colloidal gold particles labeled with rabies virus glycoprotein as the tracer. The assay was evaluated using sera from dogs immunized with various commercial rabies vaccines, or from dogs in the clinics and sera from dogs immunized with vaccines against pathogens other than rabies virus, and negative sera from a wide variety of animal sources, including dogs, mice, and cats which had never been vaccinated. The ICTS was found to be highly specific for antibodies against rabies virus, with a detection limit of 0.5IU/ml as measured by the fluorescent antibody virus neutralization (FAVN) test. Compared with the FAVN test, the specificity and sensitivity of ICTS were 98.2% and 90.4%, respectively. There was an excellent agreement between results obtained by the ICTS and FAVN tests (kappa=0.888). Strips stored at 4°C in a plastic bag with a desiccant retained their specificity and sensitivity for at least 15 months, and strips stored at ambient temperature remained stable for 12 months. The immunochromatographic test strip may therefore be useful for clinical laboratories lacking specialized equipment and for diagnosis in the field for rapid detection of rabies virus-specific antibodies. Copyright © 2010 Elsevier B.V. All rights reserved.
Application of miRNAs as Biomarkers of Exposure and Effects ...
Of the known epigenetic mechanisms, non-coding RNA and more specifically, microRNA (miRNA), offer the most immediate promise for risk assessment applications because these molecules can serve as excellent biomarkers of toxicity. The advantages of miRNA versus more classical protein toxicity biomarkers include: greater stability and earlier appearance in biofluids that can be obtained by relatively non-invasive approaches; tissue- and/or cell-specific expression patterns; evolutionary conservation in both sequence and function across species; and novel technologies for sensitive and accurate quantification. Further, information on individual miRNA is readily available through databases such as miRBase and others. Thus miRNA biomarkers offer substantial benefits in terms of cost, time, convenience, sensitivity, and specificity when assessing environmental-induced toxicity in model systems or human cohorts. Although this field is rapidly expanding, documented examples include associations of miR-155 with lymphocytic leukemia, miR-122 with liver toxicity; miR-206 with skeletal muscle disease; and miR-208a-3p with cardiac toxicity. Despite their promise, some challenges in using miRNAs as toxicity biomarkers remain, including the need for improved methods for normalizing miRNA measurements, translating findings of biofluid-based miRNA biomarker alterations in experimental models to human health and specific cell/tissue injury, and finally, the need to better defi
A Fast, Accurate and Sensitive GC-FID Method for the Analyses of Glycols in Water and Urine
NASA Technical Reports Server (NTRS)
Kuo, C. Mike; Alverson, James T.; Gazda, Daniel B.
2017-01-01
Glycols, specifically ethylene glycol and 1,2-propanediol, are some of the major organic compounds found in the humidity condensate samples collected on the International Space Station. The current analytical method for glycols is a GC/MS method with direct sample injection. This method is simple and fast, but it is not very sensitive. Reporting limits for ethylene glycol and 1,2-propanediol are only 1 ppm. A much more sensitive GC/FID method was developed, in which glycols were derivatized with benzoyl chloride for 10 minutes before being extracted with hexane. Using 1,3-propanediol as an internal standard, the detection limits for the GC/FID method was determined to be 50 ppb and the analysis only takes 7 minutes. Data from the GC/MS and the new GC/FID methods shows excellent agreement with each other. Factors affecting the sensitivity, including sample volume, NaOH concentration and volume, volume of benzoyl chloride, reaction time and temperature, were investigated. Interferences during derivatization and possible method to reduce interferences were also investigated.
Yi, Zi; Li, Xiao-Yan; Gao, Qing; Tang, Li-Juan; Chu, Xia
2013-04-07
A novel aptamer biosensor for cancer cell assay has been reported on the basis of ultrasensitive electrochemical detection. Cancer cell capturing is first accomplished via aptamer-aided recognition, and the cell-aptamer binding events then mediate an alkaline phosphatase-catalyzed silver deposition reaction which can be probed by electrochemical detection. Following biocatalytic silver deposition, an efficient amplification approach for sensitive electrochemical measurements is demonstrated, for cell detection with high sensitivity. Ramos cell are used as a model case, a typical biomarker of the acute blood cell cancer, Burkitt's lymphoma. The results reveal that the developed technique displays desirable selectivity in Ramos cell discrimination, and linear response range from 10 to 10(6) cells with a detection limit as low as 10 cells. Due to the simple procedures, label-free and electrochemistry based detection format, this technique is simple and cost-effective, and exhibits excellent compatibility with miniaturization technologies. The electrochemical cell detection strategy may create an intrinsically specific and sensitive platform for cancer cell assay and associated studies.
Wang, Xiaoyan; Yu, Jialuo; Kang, Qi; Shen, Dazhong; Li, Jinhua; Chen, Lingxin
2016-03-15
A facile strategy was developed to prepare molecular imprinting ratiometric fluorescence sensor for highly selective and sensitive detection of phycocyanin (PC) based on fluorescence resonance energy transfer (FRET), via a sol-gel polymerization process using nitrobenzoxadiazole (NBD) as fluorescent signal source. The ratio of two fluorescence peak emission intensities of NBD and PC was utilized to determine the concentration of PC, which could effectively reduce the background interference and fluctuation of diverse conditions. As a result, this sensor obtained high sensitivity with a low detection limit of 0.14 nM within 6 min, and excellent recognition specificity for PC over its analogues with a high imprinting factor of 9.1. Furthermore, the sensor attained high recoveries in the range of 93.8-110.2% at three spiking levels of PC, with precisions below 4.7% in seawater and lake water samples. The developed sensor strategy demonstrated simplicity, reliability, rapidity, high selectivity and high sensitivity, proving to be a feasible way to develop high efficient fluorescence sensors and thus potentially applicable for ultratrace analysis of complicated matrices. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
SLEIMAN, Mohamad; MADDALENA, Randy L.; GUNDEL, Lara A.
Tobacco-specific nitrosamines (TSNAs) are some of the most potent carcinogens in tobacco and cigarette smoke. Accurate quantification of these chemicals is needed to help assess public health risks. We developed and validated a specific and sensitive method to measure four TSNAs in both the gas- and particle-phase of secondhand smoke (SHS) using gas chromatography and ion-trap tandem mass spectrometry,. A smoking machine in an 18-m3 room-sized chamber generated relevant concentrations of SHS that were actively sampled on Teflon coated fiber glass (TCFG) filters, and passively sampled on cellulose substrates. A simple solid-liquid extraction protocol using methanol as solvent was successfullymore » applied to both filters with high recoveries ranging from 85 to 115percent. Tandem MS parameters were optimized to obtain the best sensitivity in terms of signal to-noise ratio (S/N) for the target compounds. For each TSNA, the major fragmentation pathways as well as ion structures were elucidated and compared with previously published data. The method showed excellent performances with a linear dynamic range between 2 and 1000 ng mL-1, low detection limits (S/N> 3) of 30-300 pg.ml-1 and precision with experimental errors below 10percent for all compounds. Moreover, no interfering peaks were observed indicating a high selectivity of MS/MS without the need for a sample clean up step. The sampling and analysis method provides a sensitive and accurate tool to detect and quantify traces of TSNA in SHS polluted indoor environments.« less
Cunningham, Jane; Hasker, Epco; Das, Pradeep; El Safi, Sayda; Goto, Hiro; Mondal, Dinesh; Mbuchi, Margaret; Mukhtar, Maowia; Rabello, Ana; Rijal, Suman; Sundar, Shyam; Wasunna, Monique; Adams, Emily; Menten, Joris; Peeling, Rosanna; Boelaert, Marleen
2012-11-15
Poor access to diagnosis stymies control of visceral leishmaniasis (VL). Antibody-detecting rapid diagnostic tests (RDTs) can be performed in peripheral health settings. However, there are many brands available and published reports of variable accuracy. Commercial VL RDTs containing bound rK39 or rKE16 antigen were evaluated using archived human sera from confirmed VL cases (n = 750) and endemic non-VL controls (n = 754) in the Indian subcontinent (ISC), Brazil, and East Africa to assess sensitivity and specificity with 95% confidence intervals. A subset of RDTs were also evaluated after 60 days' heat incubation (37°C, 45°C). Interlot and interobserver variability was assessed. All test brands performed well against ISC panels (sensitivity range, 92.8%-100%; specificity range, 96%-100%); however, sensitivity was lower against Brazil and East African panels (61.5%-91% and 36.8%-87.2%, respectively). Specificity was consistently > 95% in Brazil and ranged between 90.8% and 98% in East Africa. Performance of some products was adversely affected by high temperatures. Agreement between lots and readers was good to excellent (κ > 0.73-0.99). Diagnostic accuracy of VL RDTs varies between the major endemic regions. Many tests performed well and showed good heat stability in the ISC; however, reduced sensitivity against Brazilian and East African panels suggests that in these regions, used alone, several RDTs are inadequate for excluding a VL diagnosis. More research is needed to assess ease of use and to compare performance using whole blood instead of serum and in patients coinfected with human immunodeficiency virus.
Heutmekers, Marloes; Gillet, Philippe; Maltha, Jessica; Scheirlinck, Annelies; Cnops, Lieselotte; Bottieau, Emmanuel; Van Esbroeck, Marjan; Jacobs, Jan
2012-06-18
The present study evaluated CareStart pLDH Malaria, a three-band rapid diagnostic test detecting Plasmodium falciparum-specific parasite lactate dehydrogenase (Pf-pLDH) and pan Plasmodium-specific pLDH (pan-pLDH) in a reference setting. CareStart pLDH was retrospectively and prospectively assessed with a panel of stored (n=498) and fresh (n=77) blood samples obtained in international travelers suspected of malaria. Both panels comprised all four Plasmodium species; the retrospective panel comprised also Plasmodium negative samples. The reference method was microscopy corrected by PCR. The prospective panel was run side-to-side with OptiMAL (Pf-pLDH/pan-pLDH) and SDFK60 (histidine-rich protein-2 (HRP-2)/pan-pLDH). In the retrospective evaluation, overall sensitivity for P. falciparum samples (n=247) was 94.7%, reaching 98.7% for parasite densities>1,000/μl. Most false negative results occurred among samples with pure gametocytaemia (2/12, 16.7%) and at parasite densities ≤ 100/μl (7/12, 58.3%). None of the Plasmodium negative samples (n=96) showed visible test lines. Sensitivities for Plasmodium vivax (n=70), Plasmodium ovale (n=69) and Plasmodium malariae (n=16) were 74.3%, 31.9% and 25.0% respectively. Wrong species identification occurred in 10 (2.5%) samples and was mainly due to P. vivax samples reacting with the Pf-pLDH test line. Overall, Pf-pLDH test lines showed higher line intensities compared to the pan-pLDH lines (67.9% and 23.0% medium and strong line intensities for P. falciparum). In the prospective panel (77 Plasmodium-positive samples), CareStart pLDH showed higher sensitivities for P. falciparum compared to OptiMAL (p=0.008), lower sensitivities for P. falciparum as compare to SDFK60 (although not reaching statistical significance, p=0.08) and higher sensitivities for P. ovale compared to both OptiMAL (p=0.03) and SDFK60 (p=0.01). Inter-observer and test reproducibility were good to excellent. CareStart pLDH performed excellent for the detection of P. falciparum, well for P. vivax, but poor for P. ovale and P. malariae.
Sun, Kui; Xing, Weiwei; Yu, Xinling; Fu, Wenliang; Wang, Yuanyuan; Zou, Minji; Luo, Zhihong; Xu, Donggang
2016-08-31
With the continuous decline in prevalence and intensity of Schistosoma japonicum infection in China, more accurate and sensitive methods suitable for field detection become much needed for schistosomiasis control. Here, a novel rapid and visual detection method based on the combination of recombinase polymerase amplification (RPA) and lateral flow dipstick (LFD) was developed to detect S. japonicum DNA in fecal samples. The LFD-RPA assay targeting SjR2 could detect 5 fg S. japonicum DNA, which was identical to qPCR and real-time RPA assay, and showed no cross-reaction with other parasites. The detection could be finished within 15-20 min at a wide temperature range (25-45 °C), and the results could be visualized by naked eye. The diagnostic validity of LFD-RPA assay was further assessed with 14 fecal samples of infected patients diagnosed by Kato-Katz method and 31 fecal samples of healthy persons, and compared with that of Enzyme-linked immunosorbent assay (ELSIA) and Indirect Hemagglutination Assay (IHA). The LFD-RPA assay showed 92.68 % sensitivity, 100 % specificity and excellent diagnostic agreement with the gold standard Kato-Katz test (k = 0.947, Z = 6.36, P < 0.001), whereas ELISA showed 85.71 % sensitivity, 93.55 % specificity, and substantial diagnostic agreement (k = 0.793, Z = 5.31, P < 0.001), and IHA showed 78.57 % sensitivity, 83.87 % specificity, and moderate diagnostic agreement (k = 0.600, Z = 4.05, P < 0.001), indicating that the LFD-RPA was much better than the traditional methods. The LFD-RPA assay established by us is a sensitive, specific, rapid and convenient method for the diagnosis of schistosomiasis, and shows a great potency in field application.
Li, Wenbo; Zhao, Sheng; Wu, Nan; Zhong, Junwen; Wang, Bo; Lin, Shizhe; Chen, Shuwen; Yuan, Fang; Jiang, Hulin; Xiao, Yongjun; Hu, Bin; Zhou, Jun
2017-07-19
Wearable active sensors have extensive applications in mobile biosensing and human-machine interaction but require good flexibility, high sensitivity, excellent stability, and self-powered feature. In this work, cellular polypropylene (PP) piezoelectret was chosen as the core material of a sensitivity-enhanced wearable active voiceprint sensor (SWAVS) to realize voiceprint recognition. By virtue of the dipole orientation control method, the air layers in the piezoelectret were efficiently utilized, and the current sensitivity was enhanced (from 1.98 pA/Hz to 5.81 pA/Hz at 115 dB). The SWAVS exhibited the superiorities of high sensitivity, accurate frequency response, and excellent stability. The voiceprint recognition system could make correct reactions to human voices by judging both the password and speaker. This study presented a voiceprint sensor with potential applications in noncontact biometric recognition and safety guarantee systems, promoting the progress of wearable sensor networks.
Microstructure and mechanical behavior of low-melting point Bi-Sn-In solder joints
NASA Astrophysics Data System (ADS)
Nguyen, Van Luong; Kim, Sang Hoon; Jeong, Jae Won; Lim, Tae-Soo; Yang, Dong-Yeol; Kim, Ki Bong; Kim, Young Ja; Lee, Jun Hong; Kim, Yong-Jin; Yang, Sangsun
2017-09-01
Ternary Bi-31.5Sn-25.0In solder has been proposed and studied for application in temperature-sensitive electronic components. In a Bi-31.5Sn- 25.0In solder joint, In was detected in an intermetallic compound (IMC) layer formed at the solder/Cu substrate interface with a thickness of 4.8 μm. The microstructure of the bulk solder consisted of Sn-rich phases distributed in Bi-rich phases with dispersion of In in both phases. Meanwhile, the nanomechanical properties of the Bi-31.5Sn-25.0In solder showed great strain rate sensitivity. To be specific, hardness increased from 9.91 MPa to 56.84 MPa as the strain rate increased in the range of (0.0005-0.125) s-1. The strain-rate sensitivity exponent ( m) was found to be 0.28, indicating that the excellent ductility was shown for the solder tested under the present conditions. [Figure not available: see fulltext.
Hyperpolarized Gas MRI: Technique and Applications
McAdams, Holman P.; Kaushik, S. Sivaram; Driehuys, Bastiaan
2015-01-01
Synopsis Functional imaging today offers a rich world of information that is more sensitive to changes in lung structure and function than traditionally obtained pulmonary function tests. Hyperpolarized helium (3He) and xenon (129Xe) MR imaging of the lungs provided new sensitive contrast mechanisms to probe changes in pulmonary ventilation, microstructure and gas exchange. With the recent scarcity in the supply of 3He the field of hyperpolarized gas imaging shifted to the use of cheaper and naturally available 129Xe. Xenon is well tolerated and recent technical advances have ensured that the 129Xe image quality is on par with that of 3He. The added advantage of 129Xe is its solubility in pulmonary tissue, which allows exploring specific lung function characteristics involved in gas exchange and alveolar oxygenation. With a plethora of contrast mechanisms, hyperpolarized gases and 129Xe in particular, stands to be an excellent probe of pulmonary structure and function, and provide sensitive and non-invasive biomarkers for a wide variety of pulmonary diseases. PMID:25952516
Huijts, Susanne M.; Wu, Kangjian; Souza, Victor; Passador, Sherry; Tinder, Chunyan; Song, Esther; Elfassy, Arik; McNeil, Lisa; Menton, Ronald; French, Roger; Callahan, Janice; Webber, Chris; Gruber, William C.; Bonten, Marc J. M.; Jansen, Kathrin U.
2012-01-01
To improve the clinical diagnosis of pneumococcal infection in bacteremic and nonbacteremic community-acquired pneumonia (CAP), a Luminex technology-based multiplex urinary antigen detection (UAD) diagnostic assay was developed and validated. The UAD assay can simultaneously detect 13 different serotypes of Streptococcus pneumoniae by capturing serotype-specific S. pneumoniae polysaccharides (PnPSs) secreted in human urine. Assay specificity is achieved by capturing the polysaccharides with serotype-specific monoclonal antibodies (MAbs) on spectrally unique microspheres. Positivity for each serotype was based on positivity cutoff values calculated from a standard curve run on each assay plate together with positive- and negative-control urine samples. The assay is highly specific, since significant signals are detected only when each PnPS was paired with its homologous MAb-coated microspheres. Validation experiments demonstrated excellent accuracy and precision. The UAD assay and corresponding positivity cutoff values were clinically validated by assessing 776 urine specimens obtained from patients with X-ray-confirmed CAP. The UAD assay demonstrated 97% sensitivity and 100% specificity using samples obtained from patients with bacteremic, blood culture-positive CAP. Importantly, the UAD assay identified Streptococcus pneumoniae (13 serotypes) in a proportion of individuals with nonbacteremic CAP, a patient population for which the pneumococcal etiology of CAP was previously difficult to assess. Therefore, the UAD assay provides a specific, noninvasive, sensitive, and reproducible tool to support vaccine efficacy as well as epidemiological evaluation of pneumococcal disease, including CAP, in adults. PMID:22675155
Pride, Michael W; Huijts, Susanne M; Wu, Kangjian; Souza, Victor; Passador, Sherry; Tinder, Chunyan; Song, Esther; Elfassy, Arik; McNeil, Lisa; Menton, Ronald; French, Roger; Callahan, Janice; Webber, Chris; Gruber, William C; Bonten, Marc J M; Jansen, Kathrin U
2012-08-01
To improve the clinical diagnosis of pneumococcal infection in bacteremic and nonbacteremic community-acquired pneumonia (CAP), a Luminex technology-based multiplex urinary antigen detection (UAD) diagnostic assay was developed and validated. The UAD assay can simultaneously detect 13 different serotypes of Streptococcus pneumoniae by capturing serotype-specific S. pneumoniae polysaccharides (PnPSs) secreted in human urine. Assay specificity is achieved by capturing the polysaccharides with serotype-specific monoclonal antibodies (MAbs) on spectrally unique microspheres. Positivity for each serotype was based on positivity cutoff values calculated from a standard curve run on each assay plate together with positive- and negative-control urine samples. The assay is highly specific, since significant signals are detected only when each PnPS was paired with its homologous MAb-coated microspheres. Validation experiments demonstrated excellent accuracy and precision. The UAD assay and corresponding positivity cutoff values were clinically validated by assessing 776 urine specimens obtained from patients with X-ray-confirmed CAP. The UAD assay demonstrated 97% sensitivity and 100% specificity using samples obtained from patients with bacteremic, blood culture-positive CAP. Importantly, the UAD assay identified Streptococcus pneumoniae (13 serotypes) in a proportion of individuals with nonbacteremic CAP, a patient population for which the pneumococcal etiology of CAP was previously difficult to assess. Therefore, the UAD assay provides a specific, noninvasive, sensitive, and reproducible tool to support vaccine efficacy as well as epidemiological evaluation of pneumococcal disease, including CAP, in adults.
Achieving BLISS: Challenges for Building Fast, Ultra-Sensitive Transition-Edge Sensors
NASA Technical Reports Server (NTRS)
Beyer, Andrew D.; Runyan, M. C.; Kenyon, M.; Echternach, P. M .; Chui, T.; Bumble, B.; Bradford, C. M.; Holmes, W. A.; Bock, J. J.
2012-01-01
Topics: 1.Motivation and Intro to TESs. 2. BLISS Specifications-tolerance to dark power. 3.Measuring stray (dark) power-Tc (alpha) and G measurements. a) Overview two methods: JTD vs. TES. b) TES arrays: measurement and complications for Pd, Tc, and alpha. 4. Results: Pd compare, NEP, tau, 1/f issues. LIRGs and ULIRGs: Excellent example of distinct optical/UV and IR luminosity. Interaction long known, but huge luminosity is not predicted based on optical studies. (greater than 90% of the energy is emitted at in the far-IR). Large luminosity has both starburst and accretion components.
Sol-Gel Processing of MgF2 Antireflective Coatings
Löbmann, Peer
2018-01-01
There are different approaches for the preparation of porous antireflective λ/4 MgF2 films from liquid precursors. Among these, the non-aqueous fluorolytic synthesis of precursor solutions offers many advantages in terms of processing simplicity and scalability. In this paper, the structural features and optical performance of the resulting films are highlighted, and their specific interactions with different inorganic substrates are discussed. Due to their excellent abrasion resistance, coatings have a high potential for applications on glass. Using solvothermal treatment of precursor solutions, also the processing of thermally sensitive polymer substrates becomes feasible. PMID:29724064
3D graphene from CO 2 and K as an excellent counter electrode for dye-sensitized solar cells
Wei, Wei; Stacchiola, Dario J.; Hu, Yun Hang
2017-07-19
3D graphene, which was synthesized directly from CO 2 via its exothermic reaction with liquid K, exhibited excellent performance as a counter electrode for a dye-sensitized solar cell (DSSC). The DSSC has achieved a high power conversion efficiency of 8.25%, which is 10 times larger than that (0.74%) of a DSSC with a counter electrode of the regular graphene synthesized via chemical exfoliation of graphite. The efficiency is even higher than that (7.73%) of a dye-sensitized solar cell with an expensive standard Pt counter electrode. This work provides a novel approach to use a greenhouse gas for DSSCs.
Layer-by-Layer Polyelectrolyte Encapsulation of Mycoplasma pneumoniae for Enhanced Raman Detection
Rivera-Betancourt, Omar E.; Sheppard, Edward S.; Krause, Duncan C.; Dluhy, Richard A.
2014-01-01
Mycoplasma pneumoniae is a major cause of respiratory disease in humans and accounts for as much as 20% of all community-acquired pneumonia. Existing mycoplasma diagnosis is primarily limited by the poor success rate at culturing the bacteria from clinical samples. There is a critical need to develop a new platform for mycoplasma detection that has high sensitivity, specificity, and expediency. Here we report the layer-by-layer (LBL) encapsulation of M. pneumoniae cells with Ag nanoparticles in a matrix of the polyelectrolytes poly(allylamine hydrochloride) (PAH) and poly(styrene sulfonate) (PSS). We evaluated nanoparticle encapsulated mycoplasma cells as a platform for the differentiation of M. pneumoniae strains using surface enhanced Raman scattering (SERS) combined with multivariate statistical analysis. Three separate M. pneumoniae strains (M129, FH and II-3) were studied. Scanning electron microscopy and fluorescence imaging showed that the Ag nanoparticles were incorporated between the oppositely charged polyelectrolyte layers. SERS spectra showed that LBL encapsulation provides excellent spectral reproducibility. Multivariate statistical analysis of the Raman spectra differentiated the three M. pneumoniae strains with 97 – 100% specificity and sensitivity, and low (0.1 – 0.4) root mean square error. These results indicated that nanoparticle and polyelectrolyte encapsulation of M. pneumoniae is a potentially powerful platform for rapid and sensitive SERS-based bacterial identification. PMID:25017005
Alonso, Roberto; Pérez-García, Felipe; López-Roa, Paula; Alcalá, Luis; Rodeño, Pilar; Bouza, Emilio
2018-03-01
Detection of hepatitis C virus (HCV) RNA and the HCV core antigen assay (HCV-Ag) are reliable techniques for the diagnosis of active and chronic HCV infection. Our aim was to evaluate the HCV-Ag assay as an alternative to quantification of HVC RNA. A comparison was made of the sensitivity and specificity of an HCV-Ag assay (204 serum samples) with those of a PCR assay, and the correlation between the two techniques was determined. The sensitivity and specificity of HCV-Ag was 76.6% and 100%, respectively. Both assays were extremely well correlated (Pearson coefficient=0.951). The formula (LogCV=1.15*LogAg+2.26) was obtained to calculate the viral load by PCR from HCV-Ag values. HCV-Ag was unable to detect viral loads below 5000IU/mL. Although the HCV-Ag assay was less sensitive than the PCR assay, the correlation between both assays was excellent. HCV-Ag can be useful as a first step in the diagnosis of acute or chronic HCV infection and in emergency situations. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.
Tan, Melanie; Mol, Gerben C; van Rooden, Cornelis J; Klok, Frederikus A; Westerbeek, Robin E; Iglesias Del Sol, Antonio; van de Ree, Marcel A; de Roos, Albert; Huisman, Menno V
2014-07-24
Accurate diagnostic assessment of suspected ipsilateral recurrent deep vein thrombosis (DVT) is a major clinical challenge because differentiating between acute recurrent thrombosis and residual thrombosis is difficult with compression ultrasonography (CUS). We evaluated noninvasive magnetic resonance direct thrombus imaging (MRDTI) in a prospective study of 39 patients with symptomatic recurrent ipsilateral DVT (incompressibility of a different proximal venous segment than at the prior DVT) and 42 asymptomatic patients with at least 6-month-old chronic residual thrombi and normal D-dimer levels. All patients were subjected to MRDTI. MRDTI images were judged by 2 independent radiologists blinded for the presence of acute DVT and a third in case of disagreement. The sensitivity, specificity, and interobserver reliability of MRDTI were determined. MRDTI demonstrated acute recurrent ipsilateral DVT in 37 of 39 patients and was normal in all 42 patients without symptomatic recurrent disease for a sensitivity of 95% (95% CI, 83% to 99%) and a specificity of 100% (95% CI, 92% to 100%). Interobserver agreement was excellent (κ = 0.98). MRDTI images were adequate for interpretation in 95% of the cases. MRDTI is a sensitive and reproducible method for distinguishing acute ipsilateral recurrent DVT from 6-month-old chronic residual thrombi in the leg veins. © 2014 by The American Society of Hematology.
Liu, Su; Wang, Yu; Xu, Wei; Leng, Xueqi; Wang, Hongzhi; Guo, Yuna; Huang, Jiadong
2017-02-15
In this paper, a novel sandwich-type electrochemical aptasensor has been fabricated and applied for sensitive and selective detection of antibiotic oxytetracycline (OTC). This sensor was based on graphene-three dimensional nanostructure gold nanocomposite (GR-3D Au) and aptamer-AuNPs-horseradish peroxidase (aptamer-AuNPs-HRP) nanoprobes as signal amplification. Firstly, GR-3D Au film was modified on glassy carbon electrode only by one-step electrochemical coreduction with graphite oxide (GO) and HAuCl 4 at cathodic potentials, which enhanced the electron transfer and loading capacity of biomolecules. Then the aptamer and HRP modified Au nanoparticles provide high affinity and ultrasensitive electrochemical probe with excellent specificity for OTC. Under the optimized conditions, the peak current was linearly proportional to the concentration of OTC in the range of 5×10 -10 -2×10 -3 gL -1 , with a detection limit of 4.98×10 -10 gL -1 . Additionally, this aptasensor had the advantages in high sensitivity, superb specificity and showed good recovery in synthetic samples. Hence, the developed sandwich-type electrochemical aptasensor might provide a useful and practical tool for OTC determination and related food safety analysis and clinical diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.
Zivanovic, Mirjana; Atanasković-Marković, Marina; Medjo, Biljana; Gavrović-Jankulović, Marija; Smiljanić, Katarina; Tmušić, Vladimir; Djurić, Vojislav
2017-04-01
IgE- mediated food allergy affects 6-8% of children. Our study aimed to define the correlations between the results obtained with skin prick tests (SPTs) using commercial extracts and fresh foods, and the correlations between these result and those obtained with specific IgE (sIgE) and/ or challenge. Children aged from 2 months to 6 years were recruited prospectively. Overall 571 children were positive to one food. In all children we performed SPT using commercial extracts of suspected food and fresh foods and sIgE. If SPT and sIgE test results did not correspond to the history, we performed open oral food challenge. Sensitivity of SPT with commercial extracts for all tested food was poor (3-35%), while sensitivity of fresh food skin prick tests (FFSPT) was excellent (50-100%), and showed correlation with open oral food challenge (p<0.001). Our results suggest that fresh food extracts are more effective in detecting sensitization and with levels of sIgE greater than class 3 could predict clinical reactivity, without the need for potentially hazardous food challenges.
Li, Dongdong; An, Jingna; Wang, Tingting; Tao, Chuanmin; Wang, Lanlan
2016-11-01
The resurgence of syphilis in recent years has become a serious threat to the public health worldwide, and the serological detection of specific antibodies against Treponema pallidum (TP) remains the most reliable method for laboratory diagnosis of syphilis. The performance of the Elecsys ® Syphilis assay, a brand new electrochemiluminescene immunoassay (ECLIA), was assessed by large amounts of samples in this study. In comparison with InTec assay, the Elecsys ® Syphilis assay was evaluated in 146 preselected samples from patients with syphilis, 1803 clinical routine samples, and 175 preselected samples from specific populations with reportedly increased rates of false-positive syphilis test results. Discrepancy samples must be investigated by Mikrogen Syphilis recomline assay. There was an overall agreement of 99.58% between two assays (Kappa = 0.975). The sensitivity and specificity of the Elecsys ® Syphilis assay were 100.0% (95% CI, 96.8-100.0%) and 99.8% (95% CI, 99.5-100.0%), respectively. The Elecsys syphilis assay displays better sensitivity (100%), specificity (99.8%), PPV (98.7%), and NPV (100%) in 2124 samples enrolled, compared with the InTec assay. Considering the excellent ease of use and automation, high throughput, and its superior sensitivity, especially in primary syphilis, the Elecsys ® Syphilis assay could represent an outstanding choice for screening of syphilis in high-volume laboratories. However, more attention was still needed, or the results must be confirmed by other treponemal immunoassays. The new Elecsys ® Syphilis assay is applied to patients with malignant neoplasm or HIV infection. © 2016 Wiley Periodicals, Inc.
Reliability and validity of the work and social adjustment scale in phobic disorders.
Mataix-Cols, David; Cowley, Amy J; Hankins, Matthew; Schneider, Andreas; Bachofen, Martin; Kenwright, Mark; Gega, Lina; Cameron, Rachel; Marks, Isaac M
2005-01-01
The Work and Social Adjustment Scale (WSAS) is a simple widely used 5-item measure of disability whose psychometric properties need more analysis in phobic disorders. The reliability, factor structure, validity, and sensitivity to change of the WSAS were studied in 205 phobic patients (73 agoraphobia, 62 social phobia, and 70 specific phobia) who participated in various open and randomized trials of self-exposure therapy. Internal consistency of the WSAS was excellent in all phobics pooled and in agoraphobics and social phobics separately. Principal components analysis extracted a single general factor of disability. Specific phobics gave less consistent ratings across WSAS items, suggesting that some items were less relevant to their problem. Internal consistency was marginally higher for self-ratings than clinician ratings of the WSAS. Self-ratings and clinician ratings correlated highly though patients tended to rate themselves as more disabled than clinicians did. WSAS total scores reflected differences in phobic severity and improvement with treatment. The WSAS is a valid, reliable, and change-sensitive measure of work/social and other adjustment in phobic disorders, especially in agoraphobia and social phobia.
Norman, Sonya B.; Campbell-Sills, Laura; Hitchcock, Carla A.; Sullivan, Sarah; Rochlin, Alexis; Wilkins, Kendall C.; Stein, Murray B.
2010-01-01
Brief measures of anxiety related severity and impairment that can be used across anxiety disorders and with subsyndromal anxiety are lacking. The Overall Anxiety Severity and Impairment Scale (OASIS) have shown strong psychometric properties with college students and primary care patients. This study examines sensitivity, specificity, and efficiency of an abbreviated version of the OASIS that takes only 2–3 minutes to complete using a non-clinical (college student) sample. 48 participants completed the OASIS and SCID for anxiety disorders, 21 had a diagnosis of ≥1 anxiety disorder, and 4 additional participants had a subthreshold diagnosis. A cut-score of 8 best discriminated those with anxiety disorders from those without, successfully classifying 78% of the sample with 69% sensitivity and 74% specificity. Results from a larger sample (n=171) showed a single factor structure and excellent convergent and divergent validity. The availability of cut-scores for a non-clinical sample furthers the utility of this measure for settings where screening or brief assessment of anxiety is needed. PMID:20609450
Evaluation of 9 rapid diagnostic tests for screening HIV infection, in Lomé, Togo.
Dagnra, A Y; Dossim, S; Salou, M; Nyasenu, T; Ali-Edje, K; Ouro-Médeli, A; Doufan, M; Ehlan, A; Prince-David, M
2014-12-01
HIV rapid diagnostic tests (RDT) could be greatly contributive for a universal access to HIV diagnosis. However, according to the WHO, these tests need to be assessed before they can be used in routine. We assessed 9 RDT in routine clinical use between 2009 and 2013. The sensitivity and specificity observed for 7 tests were≥99% and≥98%, respectively: FIRST RESPONSE HIV1-2-O PMC Medical, India, GENIE Fast HIV 1-2 and GENIE™ III HIV(1/2) Bio-Rad, France, HIV TRI-DOT+Ag;J. Mitra, INDIA; SD BIOLINE HIV(1/2) 3.0 and SD BIOLINE HIV/SYPHILIS DUO Standard Diagnostic, Korea; and VIKIA HIV(1/2); BioMérieux, France. Two tests had performances inferior to WHO recommendations: INSTI HIV1/2 Biolytical Canada; sensitivity=97.8% and HEXAGON HIV HUMAN GmbH Germany; specificity=94.8%. Seven of 9 RDT had excellent performances. Nevertheless, they can be used only after training staff, and taking into account national algorithm for their safe use. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Edalati, Sh; Houshangi far, A.; Torabi, N.; Baneshi, Z.; Behjat, A.
2017-02-01
Poly(3,4-ethylendioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) was deposited on a fluoride-doped tin oxide glass substrate using a heuristic method to fabricate platinum-free counter electrodes for dye-sensitized solar cells (DSSCs). In this heuristic method a thin layer of PEDOT:PPS is obtained by spin coating the PEDOT:PSS on a Cu substrate and then removing the substrate with FeCl3. The characteristics of the deposited PEDOT:PSS were studied by energy dispersive x-ray analysis and scanning electron microscopy, which revealed the micro-electronic specifications of the cathode. The aforementioned DSSCs exhibited a solar conversion efficiency of 3.90%, which is far higher than that of DSSCs with pure PEDOT:PSS (1.89%). This enhancement is attributed not only to the micro-electronic specifications but also to the HNO3 treatment through our heuristic method. The results of cyclic voltammetry, electrochemical impedance spectroscopy (EIS) and Tafel polarization plots show the modified cathode has a dual function, including excellent conductivity and electrocatalytic activity for iodine reduction.
Evaluation of a rapid, real-time intrapartum group B Streptococcus assay
YOUNG, Brett C.; DODGE, Laura E.; GUPTA, Munish; RHEE, Julie S.; HACKER, Michele R.
2011-01-01
OBJECTIVE To evaluate an intrapartum nucleic acid amplification test (NAAT) for Group B streptococcus (GBS). STUDY DESIGN Prospective cohort study of 559 women comparing intrapartum GBS culture with antepartum culture and intrapartum NAAT. RESULTS GBS prevalence was 19.5% by antepartum culture and 23.8% by intrapartum culture. Compared with intrapartum culture, antepartum culture had 69.2% sensitivity (60.6–76.9) and 96.0% specificity (93.7–97.7). The NAAT demonstrated sensitivity of 90.8% (84.6–95.2), specificity of 97.6% (95.6–98.8), and predictive values exceeding 92%. The incidence of discordant cultures was 10.4%. Of the women with negative antepartum and positive intrapartum cultures, only 1 (2.4%) received intrapartum antibiotics. Compared with white women, black (P=0.02) and Hispanic (P=0.02) women were more likely to have discordant cultures. CONCLUSION This intrapartum NAAT has excellent characteristics. It may be superior to antepartum culture for detecting intrapartum GBS—allowing more accurate management of laboring mothers and reducing neonatal GBS sepsis. PMID:21864820
Lino, Valéria Teresa Saraiva; Portela, Margareth Crisóstomo; Camacho, Luiz Antonio Bastos; Rodrigues, Nadia Cristina Pinheiro; Andrade, Monica Kramer de Noronha; O'Dwyer, Gisele
2016-07-21
The objectives were to examine psychometric properties of a screening test for the elderly and to propose a protocol for use in primary care. The method consisted of four stages: (1) inter-evaluator reliability for performance tests and self-assessment questions for eight functions; (2) sensitivity and specificity of questions on depression and social support; (3) meeting of experts to select instrumental activities of daily living (IADL); and (4) elaboration of the protocol. Screening lasted 16 minutes. Inter-evaluator reliability was excellent for performance tests but poor for questions. Depression and social support showed satisfactory sensitivity and specificity (0.74/0.77 and 0.77/0.96). Four IADL were selected by more than 55% of the experts. Following the results, a screening protocol was elaborated that prioritized the use of performance tests, maintaining questions on mood, social support, and IADL. The study suggests better reproducibility of performance tests when compared to questions. For mood and social support, the questions may provide a first screening stage. The proposed protocol allows rapid screening of problems.
Clinical utility of the mini-mental status examination when assessing decision-making capacity.
Pachet, Arlin; Astner, Kevin; Brown, Lenora
2010-03-01
The main objectives of this study were to examine the relationship between cognitive deficits, as measured by the Mini-Mental Status Examination (MMSE), and decision-making capacity and to determine whether the sensitivity and specificity of the MMSE varied based upon the patient population assessed. Using a sample size of 152 patients and varying cutoff scores, the MMSE demonstrated extremely poor sensitivity. In contrast, the MMSE had excellent specificity when scores of 19 or less were obtained. In our sample, not one patient, regardless of diagnosis, was deemed to have capacity if their MMSE score was below 20. However, reliance on the MMSE for scores above 19 would too frequently lead to misclassification and incorrect assumptions about a patient's decision-making abilities. Although a score below 20 consistently yielded findings of incapability in our sample, it remains our opinion that the MMSE should not be used as a stand-alone tool to make determinations related to capacity, especially when considering the complexities associated with capacity evaluations and the vital areas, such as executive functioning and individual values and beliefs, which are omitted by the MMSE.
[Diagnostic tools for canine parvovirus infection].
Proksch, A L; Hartmann, K
2015-01-01
Canine parvovirus (CPV) infection is one of the most important and common infectious diseases in dogs, in particular affecting young puppies when maternal antibodies have waned and vaccine-induced antibodies have not yet developed. The mortality rate remains high. Therefore, a rapid and safe diagnostic tool is essential to diagnose the disease to 1) provide intensive care treatment and 2) to identify virus-shedding animals and thus prevent virus spread. Whilst the detection of antibodies against CPV is considered unsuitable to diagnose the disease, there are several different methods to directly detect complete virus, virus antigen or DNA. Additionally, to test in commercial laboratories, rapid in-house tests based on ELISA are available worldwide. The specificity of the ELISA rapid in-house tests is reported to be excellent. However, results on sensitivity vary and high numbers of false-negative results are commonly reported, which potentially leads to misdiagnosis. Polymerase chain reaction (PCR) is a very sensitive and specific diagnostic tool. It also provides the opportunity to differentiate vaccine strains from natural infection when sequencing is performed after PCR.
Plagnol, Vincent; Woodhouse, Samuel; Howarth, Karen; Lensing, Stefanie; Smith, Matt; Epstein, Michael; Madi, Mikidache; Smalley, Sarah; Leroy, Catherine; Hinton, Jonathan; de Kievit, Frank; Musgrave-Brown, Esther; Herd, Colin; Baker-Neblett, Katherine; Brennan, Will; Dimitrov, Peter; Campbell, Nathan; Morris, Clive; Rosenfeld, Nitzan; Clark, James; Gale, Davina; Platt, Jamie; Calaway, John; Jones, Greg; Forshew, Tim
2018-01-01
Circulating tumor DNA (ctDNA) analysis is being incorporated into cancer care; notably in profiling patients to guide treatment decisions. Responses to targeted therapies have been observed in patients with actionable mutations detected in plasma DNA at variant allele fractions (VAFs) below 0.5%. Highly sensitive methods are therefore required for optimal clinical use. To enable objective assessment of assay performance, detailed analytical validation is required. We developed the InVisionFirst™ assay, an assay based on enhanced tagged amplicon sequencing (eTAm-Seq™) technology to profile 36 genes commonly mutated in non-small cell lung cancer (NSCLC) and other cancer types for actionable genomic alterations in cell-free DNA. The assay has been developed to detect point mutations, indels, amplifications and gene fusions that commonly occur in NSCLC. For analytical validation, two 10mL blood tubes were collected from NSCLC patients and healthy volunteer donors. In addition, contrived samples were used to represent a wide spectrum of genetic aberrations and VAFs. Samples were analyzed by multiple operators, at different times and using different reagent Lots. Results were compared with digital PCR (dPCR). The InVisionFirst assay demonstrated an excellent limit of detection, with 99.48% sensitivity for SNVs present at VAF range 0.25%-0.33%, 92.46% sensitivity for indels at 0.25% VAF and a high rate of detection at lower frequencies while retaining high specificity (99.9997% per base). The assay also detected ALK and ROS1 gene fusions, and DNA amplifications in ERBB2, FGFR1, MET and EGFR with high sensitivity and specificity. Comparison between the InVisionFirst assay and dPCR in a series of cancer patients showed high concordance. This analytical validation demonstrated that the InVisionFirst assay is highly sensitive, specific and robust, and meets analytical requirements for clinical applications.
Howarth, Karen; Lensing, Stefanie; Smith, Matt; Epstein, Michael; Madi, Mikidache; Smalley, Sarah; Leroy, Catherine; Hinton, Jonathan; de Kievit, Frank; Musgrave-Brown, Esther; Herd, Colin; Baker-Neblett, Katherine; Brennan, Will; Dimitrov, Peter; Campbell, Nathan; Morris, Clive; Rosenfeld, Nitzan; Clark, James; Gale, Davina; Platt, Jamie; Calaway, John; Jones, Greg
2018-01-01
Circulating tumor DNA (ctDNA) analysis is being incorporated into cancer care; notably in profiling patients to guide treatment decisions. Responses to targeted therapies have been observed in patients with actionable mutations detected in plasma DNA at variant allele fractions (VAFs) below 0.5%. Highly sensitive methods are therefore required for optimal clinical use. To enable objective assessment of assay performance, detailed analytical validation is required. We developed the InVisionFirst™ assay, an assay based on enhanced tagged amplicon sequencing (eTAm-Seq™) technology to profile 36 genes commonly mutated in non-small cell lung cancer (NSCLC) and other cancer types for actionable genomic alterations in cell-free DNA. The assay has been developed to detect point mutations, indels, amplifications and gene fusions that commonly occur in NSCLC. For analytical validation, two 10mL blood tubes were collected from NSCLC patients and healthy volunteer donors. In addition, contrived samples were used to represent a wide spectrum of genetic aberrations and VAFs. Samples were analyzed by multiple operators, at different times and using different reagent Lots. Results were compared with digital PCR (dPCR). The InVisionFirst assay demonstrated an excellent limit of detection, with 99.48% sensitivity for SNVs present at VAF range 0.25%-0.33%, 92.46% sensitivity for indels at 0.25% VAF and a high rate of detection at lower frequencies while retaining high specificity (99.9997% per base). The assay also detected ALK and ROS1 gene fusions, and DNA amplifications in ERBB2, FGFR1, MET and EGFR with high sensitivity and specificity. Comparison between the InVisionFirst assay and dPCR in a series of cancer patients showed high concordance. This analytical validation demonstrated that the InVisionFirst assay is highly sensitive, specific and robust, and meets analytical requirements for clinical applications. PMID:29543828
Luciferase-Zinc-Finger System for the Rapid Detection of Pathogenic Bacteria.
Shi, Chu; Xu, Qing; Ge, Yue; Jiang, Ling; Huang, He
2017-08-09
Rapid and reliable detection of pathogenic bacteria is crucial for food safety control. Here, we present a novel luciferase-zinc finger system for the detection of pathogens that offers rapid and specific profiling. The system, which uses a zinc-finger protein domain to probe zinc finger recognition sites, was designed to bind the amplified conserved regions of 16S rDNA, and the obtained products were detected using a modified luciferase. The luciferase-zinc finger system not only maintained luciferase activity but also allowed the specific detection of different bacterial species, with a sensitivity as low as 10 copies and a linear range from 10 to 10 4 copies per microliter of the specific PCR product. Moreover, the system is robust and rapid, enabling the simultaneous detection of 6 species of bacteria in artificially contaminated samples with excellent accuracy. Thus, we envision that our luciferase-zinc finger system will have far-reaching applications.
A cancer cell-specific fluorescent probe for imaging Cu2 + in living cancer cells
NASA Astrophysics Data System (ADS)
Wang, Chao; Dong, Baoli; Kong, Xiuqi; Song, Xuezhen; Zhang, Nan; Lin, Weiying
2017-07-01
Monitoring copper level in cancer cells is important for the further understanding of its roles in the cell proliferation, and also could afford novel copper-based strategy for the cancer therapy. Herein, we have developed a novel cancer cell-specific fluorescent probe for the detecting Cu2 + in living cancer cells. The probe employed biotin as the cancer cell-specific group. Before the treatment of Cu2 +, the probe showed nearly no fluorescence. However, the probe can display strong fluorescence at 581 nm in response to Cu2 +. The probe exhibited excellent sensitivity and high selectivity for Cu2 + over the other relative species. Under the guidance of biotin group, could be successfully used for detecting Cu2 + in living cancer cells. We expect that this design strategy could be further applied for detection of the other important biomolecules in living cancer cells.
Superparamagnetic nano-immunobeads toward food safety insurance
NASA Astrophysics Data System (ADS)
Liu, Xuefeng; Zhang, Lei; Zeng, Jing; Gao, Yan; Tang, Zhiyong
2013-07-01
In this work, superparamagnetic nano-immunobeads (SPM-NIBs) based on conjugation of superparamagnetic Fe3O4 nanoparticles with specific antibodies have been developed toward food safety insurance. The resultant SPM-NIBs exhibits excellent colloidal stability and reversible magnetic response. Vibrio parahaemolyticus, which is a main foodborne pathogenes from contaminated seafood, can be separated specifically and efficiently by the resultant SPM-NIBs. The results of bacteria separation demonstrate that the SPM-NIBs have a higher specific activity and sensitivity toward V. parahaemolyticus. About 80 % of V. parahaemolyticus cells can be captured when the concentration of the broth reaches 103 CFU/mL. Thus, the SPM-NIBs can effectively enhance the efficiency for target bacteria inspections by shortening the period of culture time. This work holds the promise of development of general technique to prepare effective SPM-NIBs toward food safety inspections and other bio-related applications for target analyte separation and collection.
Glycosylation Changes in Serum Proteins Identify Patients with Pancreatic Cancer.
Drabik, Anna; Bodzon-Kulakowska, Anna; Suder, Piotr; Silberring, Jerzy; Kulig, Jan; Sierzega, Marek
2017-04-07
After more than a decade of biomarker discovery using advanced proteomic and genomic approaches, very few biomarkers have been involved in clinical diagnostics. Most candidate biomarkers are focused on the protein component. Targeting post-translational modifications (PTMs) in combination with protein sequences will provide superior diagnostic information with regards to sensitivity and specificity. Glycosylation is one of the most common and functionally important PTMs. It plays a central role in many biological processes, including protein folding, host-pathogen interactions, immune response, and inflammation. Cancer-associated aberrant glycosylation has been identified in various types of cancer. Expression of cancer-specific glycan epitopes represents an excellent opportunity for diagnostics and potentially specific detection of tumors. Here, we report four proteins (LIFR, CE350, VP13A, HPT) found in sera from pancreatic cancer patients carrying aberrant glycan structures as compared to those of controls.
Validation of rapid suicidality screening in epilepsy using the NDDIE.
Mula, Marco; McGonigal, Aileen; Micoulaud-Franchi, Jean-Arthur; May, Theodor W; Labudda, Kirsten; Brandt, Christian
2016-06-01
Standard mortality ratio for suicide in patients with epilepsy is three times higher than in the general population, and such a risk remains high even after adjusting for clinical and socioeconomic factors. It is thus important to have suitable screening instruments and to implement care pathways for suicide prevention in every epilepsy center. The aim of this study is to validate the use of the Neurological Disorder Depression Inventory for Epilepsy (NDDIE) as a suicidality-screening instrument. The study sample included adult patients with epilepsy assessed with the Mini International Neuropsychiatric Interview (MINI) and the NDDIE. A high suicidality risk according to the Suicidality Module of the MINI was considered the gold standard. Receiver operating characteristic analyses for NDDIE total and individual item scores were computed and subsequently compared using a nonparametric approach. The best possible cutoff was identified with the highest Youden index (J). Likelihood ratios were then computed, and specificity, sensitivity, positive, and negative predictive values calculated. The study sample consisted of 380 adult patients with epilepsy: 46.3% male; mean age was 39.4 ± 14.6; 76.7% had a diagnosis of focal epilepsy; mean age at onset of the epilepsy was 23.3 ± 17.5. According to the MINI, 74 patients (19.5%) fulfilled criteria for a major depressive episode and 19 (5%) presented a high suicidality risk. A score >2 (J = 0.751) for item 4 "I'd be better off dead" of the NDDIE displayed excellent psychometric properties with a good to excellent validity (area under the curve [AUC] 0.906; 95% confidence interval [CI] 0.820-0.992; p < 0.001), sensitivity 84.21% (95% CI 60.4-96.6), specificity 90.86% (95% CI 87.4-93.6), likelihood ratio+ 9.21 (95% CI 6.3-13.5), likelihood ratio- 0.17 (95% CI 0.06-0.50). Item 4 of the NDDIE has shown to be an excellent suicidality screening instrument allowing the development of further care pathways for suicide prevention in epilepsy centers. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.
Prenatal Testosterone Programming of Insulin Resistance in the Female Sheep.
Puttabyatappa, Muraly; Padmanabhan, Vasantha
2017-01-01
Insulin resistance, a common feature of metabolic disorders such as obesity, nonalcoholic fatty liver disease, metabolic syndrome, and polycystic ovary syndrome, is a risk factor for development of diabetes. Because sex hormones orchestrate the establishment of sex-specific behavioral, reproductive, and metabolic differences, a role for them in the developmental origin of insulin resistance is also to be expected. Female sheep exposed to male levels of testosterone during fetal life serve as an excellent translational model for delineating programming of insulin resistance. This chapter summarizes the ontogeny of insulin resistance, the tissue-specific changes in insulin sensitivity, and the various factors that are involved in the programming and maintenance of the insulin resistance in adult female sheep that were developmentally exposed to fetal male levels of testosterone during the sexual-differentiation window.
Enhanced glucose biosensor properties of gold nanoparticle-decorated ZnO nanorods
NASA Astrophysics Data System (ADS)
Wang, Zi-Hao; Yang, Chih-Chiang; Su, Yan-Kuin; Ruand, Jian-Long
2017-04-01
As new materials have been reported and more knowledge on detailed mechanism of glucose oxidation has been unveiled, the non-enzymatic glucose sensor keeps coming closer to practical applications. Nanostructures with higher surface specific area has great potential applications in sensing devices ZnO nanoords were synthesized in a hydrothermal method using simply available laboratory chemicals. Results showed that as-synthesized Gold Nanoparticle-decorated ZnO Nanorods possessing higher specific surface area, significantly increased the non-enzyme efficiency which in turn improved the sensing performances. The electrode also demonstrated excellent performance in sensing glucose concentration with remarkable sensitivity (46.6 μA/mM-cm2) and good repeatability. This work is expected to open a new avenue to fabricate non-enzymatic electrochemical sensors of glucose involving co-mediating.
Shivappa, R.B.; Savan, R.; Kono, T.; Sakai, M.; Emmenegger, E.; Kurath, G.; Levine, Jay F.
2008-01-01
Spring viraemia of carp virus (SVCV) is a rhabdovirus associated with systemic illness and mortality in cyprinids. Several diagnostic tests are available for detection of SVCV. However, most of these tests are time consuming and are not well adapted for field-based diagnostics. In this study, a diagnostic tool for SVCV detection based on reverse transcription loop-mediated isothermal amplification (RT-LAMP) has been developed. Based on the nucleotide sequence of the glycoprotein (G) gene of SVCV North Carolina (NC) isolate, four sets (each set containing two outer and two inner) of primers were designed. Temperature and time conditions were optimized to 65 ??C and 60 min, respectively, for LAMP and RT-LAMP using one primer set. In vitro specificity was evaluated using four different strains of fish rhabdoviruses and RT-LAMP was found to be specific to SVCV. Serial dilutions of SVCV NC isolate was used to evaluate the in vitro sensitivity of RT-LAMP. Sensitivity of the assays was similar to RT-PCR and detected SVCV even at the lowest dilution of 10 1 TCID50 mL-1. The ability of RT-LAMP to detect SVCV from infected carp was also tested and the assay detected SVCV from all infected fish. The isothermal temperature requirements, high specificity and sensitivity, and short incubation time of the RT-LAMP assay make it an excellent choice as a field diagnostic test for SVCV. ?? 2008 The Authors.
The use of anti-Müllerian hormone as diagnostic for gonadectomy status in dogs.
Themmen, Axel P N; Kalra, Bhanu; Visser, Jenny A; Kumar, Ajay; Savjani, Gopal; de Gier, Jeffrey; Jaques, Scott
2016-10-01
In the veterinary practice, there is a need for a diagnostic tool to check the gonadal status in female dogs because it may be difficult to determine whether a female animal has been spayed or whether there are ovarian remnants. Although less prevalent, a similar situation pertains to male dogs. Anti-Müllerian hormone (AMH) is an important regulator of gonadal function and is a specific gonadal product that can be determined in circulation. The objective of this study was to develop and test a canine blood AMH assay as a diagnostic tool to determine the presence of functional gonadal tissue in dogs. A prospective study with a training-validation set paradigm was used. A canine AMH assay was developed and serum and plasma AMH concentrations were determined in blood samples from 46 intact female dogs, 48 spayed females, 50 intact males, and 48 castrated males collected at two separate institutes. Using a training-validation set paradigm, it was found that using cutoff values of 1.1 ng/mL (female) and 5.5 ng/mL (male) AMH, the assay reported excellent specificity and sensitivity of 100% and 90% in female dogs, and good specificity and sensitivity of 100% and 76%, in male dogs, respectively. The sensitivity in male dogs could be further enhanced by including a serum testosterone determination. This newly developed canine AMH assay is a valuable diagnostic tool to determine gonadal status in veterinary medicine. Copyright © 2016 Elsevier Inc. All rights reserved.
A light-up probe targeting for Bcl-2 2345 G-quadruplex DNA with carbazole TO
NASA Astrophysics Data System (ADS)
Gu, Yingchun; Lin, Dayong; Tang, Yalin; Fei, Xuening; Wang, Cuihong; Zhang, Baolian; Zhou, Jianguo
2018-02-01
As its significant role, the selective recognition of G-quadruplex with specific structures and functions is important in biological and medicinal chemistry. Carbazole derivatives have been reported as a kind of fluorescent probe with many excellent optical properties. In the present study, the fluorescence of the dye (carbazole TO) increased almost 70 fold in the presence of bcl-2 2345 G4 compared to that alone in aqueous buffer condition with almost no fluorescence and 10-30 fold than those in the presence of other DNAs. The binding study results by activity inhibition of G4/Hemin peroxidase experiment, NMR titration and molecular docking simulation showed the high affinity and selectivity to bcl-2 2345 G4 arises from its end-stacking interaction with G-quartet. It is said that a facile approach with excellent sensitive, good selectivity and quick response for bcl-2 2345 G-quadruplex was developed and may be used for antitumor recognition or antitumor agents.
Widdifield, Jessica; Bernatsky, Sasha; Paterson, J Michael; Tu, Karen; Ng, Ryan; Thorne, J Carter; Pope, Janet E; Bombardier, Claire
2013-10-01
Health administrative data can be a valuable tool for disease surveillance and research. Few studies have rigorously evaluated the accuracy of administrative databases for identifying rheumatoid arthritis (RA) patients. Our aim was to validate administrative data algorithms to identify RA patients in Ontario, Canada. We performed a retrospective review of a random sample of 450 patients from 18 rheumatology clinics. Using rheumatologist-reported diagnosis as the reference standard, we tested and validated different combinations of physician billing, hospitalization, and pharmacy data. One hundred forty-nine rheumatology patients were classified as having RA and 301 were classified as not having RA based on our reference standard definition (study RA prevalence 33%). Overall, algorithms that included physician billings had excellent sensitivity (range 94-100%). Specificity and positive predictive value (PPV) were modest to excellent and increased when algorithms included multiple physician claims or specialist claims. The addition of RA medications did not significantly improve algorithm performance. The algorithm of "(1 hospitalization RA code ever) OR (3 physician RA diagnosis codes [claims] with ≥1 by a specialist in a 2-year period)" had a sensitivity of 97%, specificity of 85%, PPV of 76%, and negative predictive value of 98%. Most RA patients (84%) had an RA diagnosis code present in the administrative data within ±1 year of a rheumatologist's documented diagnosis date. We demonstrated that administrative data can be used to identify RA patients with a high degree of accuracy. RA diagnosis date and disease duration are fairly well estimated from administrative data in jurisdictions of universal health care insurance. Copyright © 2013 by the American College of Rheumatology.
[Comparison of eight screening tests for ant-HCV antibody].
Deguchi, Matsuo; Kagita, Masanori; Yamashita, Naoko; Nakano, Takasi; Tahara, Kazuko; Asari, Seishi; Iwatani, Yoshinori
2002-09-01
We compared eight HCV screening tests for detection of anti-HCV antibody; Ortho Quick Chaser HCV Ab (QC), Ortho HCV Ab ELISA III (ELISA), Ortho HVC Ab PA test III (PA), Lumipulse II Ortho HCV (LUMI), IMx HCV.DAINAPACKII (IMx), ARCHITECT HCV (ARCH), Immucheck.F-HCV C50 Ab (Immu), RANREAM HCV Ab Ex II (RAN). Sera from six hundred patients were examined by these eight screening tests. The positive rates of the eight screening tests were from 9.0% to 13.2%. Forty-five sera showed discrepant results between the eight screening tests, and about half of them showed weak positive reaction and/or false positive. Twenty-five of the forty-five sera were negative for ant-HCV antibody in the CHIRON RIBA III confirmatory test, and forty-four of them were negative for HCV-RNA in the PCR method. The agreement rates between the two reagents were from 95.5% to 99.2%, but were not always high between the two reagents that used similar antigen. The specificities and sensitivities evaluated by using the RIBA III confirmatory test were excellent in ELISA, LUMI, IMx, ARCH and Immu. Three BBI seroconversion panels were used to compare the positive readings in the initial stage of HCV infection by eight screening tests. ELISA and ARCH showed the earliest positive readings, and then IMx, LUMI = RAN, PA, QC and Immu in this order. These findings indicate that ELISA and ARCH were the most excellent in the sensitivity, specificity and early diagnosis of HCV infection. However, we must pay attention to the weak positive reaction in the screening tests, because there is a possibility of "false positive".
Stomp, Wouter; Krabben, Annemarie; van der Heijde, Désirée; Huizinga, Tom W J; Bloem, Johan L; van der Helm-van Mil, Annette H M; Reijnierse, Monique
2014-10-01
To determine whether T1 post-gadolinium chelate images (T1Gd) can replace T2-weighted images (T2) for evaluating bone marrow oedema (BME), thereby allowing a shorter magnetic resonance imaging (MRI) protocol in rheumatoid arthritis (RA). In 179 early arthritis patients and 43 advanced RA patients, wrist and metacarpophalangeal joints were examined on a 1.5-T extremity MRI system with a standard protocol (coronal T1, T2 fat-saturated and coronal and axial T1 fat-saturated after Gd). BME was scored according to OMERACT RAMRIS by two observers with and without T2 images available. Agreement was assessed using intraclass correlation coefficients (ICCs) for semi-quantitative scores and test characteristics with T2 images as reference. Agreement between scores based on T2 and T1Gd images was excellent ICC (0.80-0.99). At bone level, sensitivity and specificity of BME on T1Gd compared to T2 were high for both patient groups and both readers (all ≥80 %). T1Gd and T2 images are equally suitable for evaluating BME. Because contrast is usually administered to assess (teno)synovitis, a short MRI protocol of T1 and T1Gd is sufficient in RA. • Bone marrow oedema scores are equal on T2 and T1-Gd-chelate enhanced sequences. • Agreement between scores based on T2 and T1-Gd-chelate images was excellent. • Sensitivity and specificity for presence of bone marrow oedema were high. • A short protocol without T2 images suffices in rheumatoid arthritis patients.
Gamble, M V; Ramakrishnan, R; Palafox, N A; Briand, K; Berglund, L; Blaner, W S
2001-03-01
Serum retinol is transported by retinol binding protein (RBP), which has one high-affinity binding site for retinol; consequently, the molar ratio of retinol to RBP in the circulation is approximately 1 to 1. In vitamin A deficiency (VAD), both serum retinol and RBP decline. However, the retinol-RBP relation has not been well studied in populations with a high incidence of severe VAD. The purpose of this study was to determine whether RBP is a good surrogate for serum retinol at the very low retinol concentrations encountered in VAD. The stoichiometric relation between retinol and RBP was studied in 239 Marshallese children: 65 with severe VAD (< or = 0.35 micromol retinol/L), 94 with moderate VAD (0.36-0.70 micromol retinol/L), and 80 with vitamin A sufficiency (> 0.70 micromol retinol/L). Excellent correlation between retinol and RBP (r = 0.94) was observed across all retinol concentrations. Severe VAD was predicted with 96% sensitivity and 91% specificity on the basis of an RBP cutoff of < or = 0.48 micromol/L, whereas moderate VAD was predicted with 87% sensitivity and 98% specificity on the basis of an RBP cutoff of < or = 0.70 micromol/L. The use of RBP results in the classification of essentially the same children with VAD as does retinol, and RBP is an excellent surrogate for serum retinol. Considering the relative ease of measuring RBP with immunodiagnostic kits compared with that of serum retinol by HPLC, the use of RBP concentrations to assess VAD may be particularly advantageous in field settings. Consequently, measuring RBP concentrations may be a practical alternative to measuring serum retinol in population surveys assessing the prevalence of VAD.
Salivary exoglycosidases as markers of alcohol dependence.
Waszkiewicz, Napoleon; Chojnowska, Sylwia; Zalewska, Anna; Zwierz, Krzysztof; Szulc, Agata; Szajda, Sławomir Dariusz
2014-01-01
Some salivary markers of alcohol abuse/dependence have been proposed so far: aminotransferases, gamma-glutamyltransferase, ethanol, ethyl glucuronide, ethyl sulfate, sialic acid, β-hexosaminidase A, oral peroxidase, methanol, diethylene/ethylene glycol, α-amylase, clusterin, haptoglobin, heavy/light chains of immunoglobulins and transferrin. To investigate the effect of chronic alcohol drinking and smoking on the activity (pKat/ml) and output (pKat/min) of salivary lysosomal exoglycosidases: α-fucosidase (FUC), α-mannosidase (MAN), β-galactosidase (GAL), and β-glucuronidase (GLU), and their applicability as markers of alcohol dependence. The activity of FUC, MAN, GAL and GLU was measured colorimetrically in the saliva of healthy social drinkers, alcohol-dependent non-smokers and alcohol-dependent smokers. We observed an increased salivary activity of FUC, GAL, GLU and MAN, as well as an increased output of GAL and GLU, in comparison with controls. The highest increase in the activity/output was found in salivary GLU and MAN (GLU, even 7- to 18-fold), and the least in GAL. We found an excellent sensitivity and specificity and a high accuracy (measured by the area under the ROC curve) for salivary FUC, GLU and MAN activities. The salivary GLU activity positively correlated with the number of days of last alcohol intoxication. Salivary activity of FUC, GAL and MAN, but not GLU, positively correlated with the periodontal parameters such as gingival index and papilla bleeding index. Although we found an excellent sensitivity and specificity as well as a high accuracy for the salivary activity of FUC, GLU and MAN, the GLU activity seems to be mostly applicable as a marker of chronic alcohol drinking (alcohol dependence). © The Author 2014. Medical Council on Alcohol and Oxford University Press. All rights reserved.
Accuracy of the radioactive copper incorporation test in the diagnosis of Wilson disease.
Członkowska, Anna; Rodo, Maria; Wierzchowska-Ciok, Agata; Smolinski, Lukasz; Litwin, Tomasz
2018-02-08
In Wilson disease (WD), copper accumulates in the liver and other tissues because of mutations in the ATP7B copper transporter gene. Early and effective anticopper treatment is crucial. However, routine diagnostic methods based on clinical findings, copper metabolism tests, liver biopsies and DNA analyses do not always provide a conclusive diagnosis. The aim was to evaluate radioactive copper incorporation as a diagnostic test. We included cases with a diagnosis of WD supported by radiocopper testing and later, when available, confirmed by DNA analysis. Incorporation of 64 Cu was measured at 2, 24 and 48 hours following intravenous injection. Diagnostic accuracy (area under the receiver operating characteristic curve [AUC]), sensitivity, specificity and predictive value were assessed for 24 hours/2 hours and 48 hours/2 hours 64 Cu ratios and compared with serum measurements of ceruloplasmin, copper, non-ceruloplasmin-bound copper and urinary 24-hours copper excretion. Patients having two pathogenic ATP7B mutations (homozygotes/compound heterozygotes) (n = 74) had significantly lower 24 hours/2 hours and 48 hours/2 hours 64 Cu ratios than heterozygote controls (n = 21) (mean 0.14 and 0.12 vs 0.49 and 0.63, respectively; both P < .001). Of note, 24 hours/2 hours and 48 hours/2 hours 64 Cu ratios had excellent diagnostic accuracy, with AUCs approaching 1, and only 24-hours urinary copper excretion displayed similar positive features. Other copper metabolism tests studied had lower accuracy, specificity and sensitivity. The radioactive copper test had excellent diagnostic accuracy and may be useful in the evaluation of new therapies aimed at restoring ATP7B function. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Lan, Feifei; Liang, Linlin; Zhang, Yan; Li, Li; Ren, Na; Yan, Mei; Ge, Shenguang; Yu, Jinghua
2017-11-01
In this work, a chemiluminescence-driven collapsible greeting card-like photoelectrochemical lab-on-paper device (GPECD) with hollow channel was demonstrated, in which target-triggering cascade DNA amplification strategy was ingeniously introduced. The GPECD had the functions of reagents storage and signal collection, and the change of configuration could control fluidic path, reaction time and alterations in electrical connectivity. In addition, three-dimentional reduced graphene oxide affixed Au flower was in situ grown on paper cellulose fiber for achieving excellent conductivity and biocompatibility. The cascade DNA amplification strategy referred to the cyclic formation of target analog chain and its trigger action to hybridization chain reaction (HCR), leading to the formation of numerous hemin/G-quadruplex DNA mimic enzyme with the presence of hemin. Subjected to the catalysis of hemin/G-quadruplex, the strong chemiluminiscence of luminol-H 2 O 2 system was obtained, which then was used as internal light source to excite photoactive materials realizing the simplification of instrument. In this analyzing process, thrombin served as proof-of-concept, and the concentration of target was converted into the DNA signal output by the specific recognition of aptamer-protein and target analog chain recycling. The target analog chain was produced in quantity with the presence of target, which further triggered abundant HCR and introduced hemin/G-quadruplex into the system. The photocurrent signal was obtained after the nitrogen-doped carbon dots sensitized ZnO was stimulated by chemiluminescence. The proposed GPECD exhibited excellent specificity and sensitivity toward thrombin with a detection limit of 16.7 fM. This judiciously engineered GPECD paved a luciferous way for detecting other protein with trace amounts in bioanalysis and clinical biomedicine.
Taborri, Juri; Rossi, Stefano; Palermo, Eduardo; Patanè, Fabrizio; Cappa, Paolo
2014-09-02
In this work, we decided to apply a hierarchical weighted decision, proposed and used in other research fields, for the recognition of gait phases. The developed and validated novel distributed classifier is based on hierarchical weighted decision from outputs of scalar Hidden Markov Models (HMM) applied to angular velocities of foot, shank, and thigh. The angular velocities of ten healthy subjects were acquired via three uni-axial gyroscopes embedded in inertial measurement units (IMUs) during one walking task, repeated three times, on a treadmill. After validating the novel distributed classifier and scalar and vectorial classifiers-already proposed in the literature, with a cross-validation, classifiers were compared for sensitivity, specificity, and computational load for all combinations of the three targeted anatomical segments. Moreover, the performance of the novel distributed classifier in the estimation of gait variability in terms of mean time and coefficient of variation was evaluated. The highest values of specificity and sensitivity (>0.98) for the three classifiers examined here were obtained when the angular velocity of the foot was processed. Distributed and vectorial classifiers reached acceptable values (>0.95) when the angular velocity of shank and thigh were analyzed. Distributed and scalar classifiers showed values of computational load about 100 times lower than the one obtained with the vectorial classifier. In addition, distributed classifiers showed an excellent reliability for the evaluation of mean time and a good/excellent reliability for the coefficient of variation. In conclusion, due to the better performance and the small value of computational load, the here proposed novel distributed classifier can be implemented in the real-time application of gait phases recognition, such as to evaluate gait variability in patients or to control active orthoses for the recovery of mobility of lower limb joints.
Müller, Stephan; Preische, Oliver; Heymann, Petra; Elbing, Ulrich; Laske, Christoph
2017-01-01
There is a considerable delay in the diagnosis of dementia, which may reduce the effectiveness of available treatments. Thus, it is of great interest to develop fast and easy to perform, non-invasive and non-expensive diagnostic measures for the early detection of cognitive impairment and dementia. Here we investigate movement kinematics between 20 patients with early dementia due to Alzheimer's disease (eDAT), 30 patients with amnestic mild cognitive impairment (aMCI), and 20 cognitively healthy control (HC) individuals while copying a three-dimensional house using a digitizing tablet. Receiver-operating characteristic (ROC) curves and logistic regression analyzes have been conducted to explore whether alterations in movement kinematics could be used to discriminate patients with aMCI and eDAT from healthy individuals. Time-in-air (i.e., transitioning from one stroke to the next without touching the surface) differed significantly between patients with aMCI, eDAT, and HCs demonstrating an excellent sensitivity and a moderate specificity to discriminate aMCI subjects from normal elderly and an excellent sensitivity and specificity to discriminate patients affected by mild Alzheimer's disease from healthy individuals. Time-on-surface (i.e., time while stylus is touching the surface) differed only between HCs and patients with eDAT but not between HCs and patients with aMCI. Furthermore, total-time (i.e., time-in-air plus time-on-surface) did not differ between patients with aMCI and early dementia due to AD. Modern digitizing devices offer the opportunity to measure a broad range of visuoconstructive abilities that may be used as a fast and easy to perform screening instrument for the early detection of cognitive impairment and dementia in primary care.
Kang, Seung-Gul; Kang, Jae Myeong; Ko, Kwang-Pil; Park, Seon-Cheol; Mariani, Sara; Weng, Jia
2017-06-01
To compare the accuracy of the commercial Fitbit Flex device (FF) with polysomnography (PSG; the gold-standard method) in insomnia disorder patients and good sleepers. Participants wore an FF and actigraph while undergoing overnight PSG. Primary outcomes were intraclass correlation coefficients (ICCs) of the total sleep time (TST) and sleep efficiency (SE), and the frequency of clinically acceptable agreement between the FF in normal mode (FFN) and PSG. The sensitivity, specificity, and accuracy of detecting sleep epochs were compared among FFN, actigraphy, and PSG. The ICCs of the TST between FFN and PSG in the insomnia (ICC=0.886) and good-sleepers (ICC=0.974) groups were excellent, but the ICC of SE was only fair in both groups. The TST and SE were overestimated for FFN by 6.5min and 1.75%, respectively, in good sleepers, and by 32.9min and 7.9% in the insomnia group with respect to PSG. The frequency of acceptable agreement of FFN and PSG was significantly lower (p=0.006) for the insomnia group (39.4%) than for the good-sleepers group (82.4%). The sensitivity and accuracy of FFN in an epoch-by-epoch comparison with PSG was good and comparable to those of actigraphy, but the specificity was poor in both groups. The ICC of TST in the FFN-PSG comparison was excellent in both groups, and the frequency of agreement was high in good sleepers but significantly lower in insomnia patients. These limitations need to be considered when applying commercial sleep trackers for clinical and research purposes in insomnia. Copyright © 2017 Elsevier Inc. All rights reserved.
Modified schirmer test--a screening tool for xerostomia among subjects on antidepressants.
Kumar, Nerella Narendra; Panchaksharappa, Mamatha Gowda; Annigeri, Rajeshwari G
2014-08-01
The aim of the present study is to assess salivary flow rate in the subjects who were on antidepressant medications and its comparison with healthy controls and assessment of unstimulated salivary flow rate by modified Schirmer test (MST) and volumetric method (spitting method) for evaluation of xerostomia and whether any correlation exists between two methods. Thirty subjects who were on antidepressants were divided into two groups: tricyclic antidepressants (TCA) and selective sertonin reuptake inhibitors (SSRI) of 15 each, compared with 30 age and gender matched controls. Unstimulated salivary flow rate was measured by both MST and spitting method. The unstimulated salivary flow rate measured by MST at the end of 3rd minute was 13.7 ± 10.08, 19.86 ± 8.95 and 31.0 ± 5.4 mm and by spitting method was 0.12 ± 0.07, 0.19 ± 0.10 and 0.30 ± 0.75 ml/min in TCA, SSRI and controls respectively (p<0.001). The Pearson correlation coefficient of r=0.85 shows excellent correlation between the two screening tests. Sensitivity and Specificity of MST was 90.9% and 31.5%. Salivary flow rate was less in antidepressant subjects when compared to the healthy controls. Results of the present study showed an excellent correlation excellent correlation between the two screening tests which suggests that MST can be routinely used as chair-side screening tool to evaluate hyposalivation which is time saving, patient friendly and specific of salivary secretions. Copyright © 2014 Elsevier Ltd. All rights reserved.
Naz, Shumaila; Desclozeaux, Marion; Mounsey, Kate E; Chaudhry, Farhana Riaz; Walton, Shelley F
2017-09-01
Scabies is a human skin disease due to the burrowing ectoparasite Sarcoptes scabiei var. hominis resulting in intense itching and inflammation and manifesting as a skin allergy. Because of insufficient mite material and lack of in vitro propagation system for antigen preparation, scabies is a challenging disease to develop serological diagnostics. For allergen characterization, full-length S. scabiei tropomyosin (Sar s 10) was cloned, expressed in pET-15b, and assessed for reactivity with IgE antibodies from human sera. IgE binding was observed to Sar s 10 with sera collected from subjects with ordinary scabies, house dust mite (HDM)-positive and naive subjects and a diagnostic sensitivity of < 30% was observed. S. scabiei paramyosin (Sar s 11) was cloned, and expressed in pET-28a in three overlapping fragments designated Sspara1, Sspara2, and Sspara3. IgE and IgG binding was observed to Sspara2 and Sspara3 antigens with sera collected from ordinary scabies, and HDM-positive subjects, but no binding was observed with sera collected from naive subjects. Sspara2 displayed excellent diagnostic potential with 98% sensitivity and 90% specificity observed for IgE binding and 70% sensitivity for IgG. In contrast, the diagnostic sensitivity of Sspara3 was 84% for IgE binding and 40% for IgG binding. In combination, Sspara2 and Sspara3 provided an IgE sensitivity of 94%. This study shows that IgE binding to Sspara2 and Sspara3 is a highly sensitive method for diagnosis of scabies infestation in clinical practice. The developed enzyme-linked immunosorbent assay helps direct future development of a specific diagnostic tool for scabies.
A Dynamic Network Model to Explain the Development of Excellent Human Performance
Den Hartigh, Ruud J. R.; Van Dijk, Marijn W. G.; Steenbeek, Henderien W.; Van Geert, Paul L. C.
2016-01-01
Across different domains, from sports to science, some individuals accomplish excellent levels of performance. For over 150 years, researchers have debated the roles of specific nature and nurture components to develop excellence. In this article, we argue that the key to excellence does not reside in specific underlying components, but rather in the ongoing interactions among the components. We propose that excellence emerges out of dynamic networks consisting of idiosyncratic mixtures of interacting components such as genetic endowment, motivation, practice, and coaching. Using computer simulations we demonstrate that the dynamic network model accurately predicts typical properties of excellence reported in the literature, such as the idiosyncratic developmental trajectories leading to excellence and the highly skewed distributions of productivity present in virtually any achievement domain. Based on this novel theoretical perspective on excellent human performance, this article concludes by suggesting policy implications and directions for future research. PMID:27148140
Eid, Issam; Miller, Frank R; Rowan, Stephanie; Otto, Randal A
2013-10-01
To determine the role and efficacy of intraoperative recurrent laryngeal nerve (RLN) stimulation in the prediction of early and permanent postoperative nerve function in thyroid and parathyroid surgery. A retrospective review of thyroid and parathyroid surgeries was performed with calculation of sensitivity and specificity of the response of intraoperative stimulation for different pathological groups. Normal electromyography (EMG) response with 0.5 mAmp stimulation was considered a positive stimulation response with postoperative function determined by laryngoscopy. No EMG response at >1-2 mAmps was considered a negative response. The rates of early and permanent paralysis, as well as sensitivity, specificity, and positive and negative predictive values for postoperative nerve function were calculated for separate pathological groups. The number of nerves at risk analyzed was 909. The overall early and permanent paralysis rates were 3.1% and 1.2%, respectively, with the highest rate being for Grave's disease cases. The overall sensitivity was 98.4%. The specificity was lower at 62.5% but acceptable in thyroid carcinoma and Grave's disease patients. The majority of nerves with a positive stimulation result and postoperative paralysis on laryngoscopy recovered function in 3 to 12 weeks, showing positive stimulation to be a good predictor of eventual recovery. Stimulation of the RLN during thyroid and parathyroid surgery is a useful tool in predicting postoperative RLN function. The sensitivity of stimulation is high, showing positive stimulation to be an excellent predictor of normal nerve function. Negative stimulation is more predictive of paralysis in cases of thyroid carcinoma and Grave's disease. 2b. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Woods, Kate L; Boutthasavong, Latsaniphone; NicFhogartaigh, Caoimhe; Lee, Sue J; Davong, Viengmon; AuCoin, David P; Dance, David A B
2018-05-02
Burkholderia pseudomallei causes significant global morbidity and mortality, with the highest disease burden in parts of Asia where culture-based diagnosis is often not available. We prospectively evaluated the Active Melioidosis Detect (AMD, InBios International, USA) lateral flow immunoassay (LFI) for rapid detection of B. pseudomallei in turbid blood cultures, pus, sputum, sterile fluid, urine, and sera. Performance was compared to B. pseudomallei detection using monoclonal antibody latex agglutination (LA) and immunofluorescence assays (IFA), with culture as the gold standard. AMD was 99% (99/100; 94.6 - 100%) sensitive and 100% (308/308; 98.8-100%) specific on turbid blood culture bottles, with no difference to LA or IFA. AMD specificity was 100% on pus (122/122; 97.0-100%), sputum (20/20; 83.2-100%), and sterile fluid (44/44; 92 - 100%). Sensitivity on these samples was: pus 47.1% (8/17; 23.0 - 72.2%), sputum 33.3% (1/3; 0.84 - 90.6%), and sterile fluid 0% (0/2; 0 - 84.2%). Urine AMD had a positive predictive value of 94% (32/34; 79.7 - 98.5%) for diagnosing melioidosis in our cohort. AMD sensitivity on stored sera, collected prospectively from melioidosis cases during this study, was 13.9% (5/36; 4.7% - 29.5%) when compared to blood culture samples taken on the same day. In conclusion, the AMD is an excellent tool for rapid diagnosis of melioidosis from turbid blood cultures, and maintains specificity across all sample types. It is a promising tool for urinary antigen detection, which could revolutionise diagnosis of melioidosis in resource-limited settings. Further work is required to improve sensitivity on non-blood culture samples. Copyright © 2018 Woods et al.
Performance of two strategies for urgent ANCA and anti-GBM analysis in vasculitis.
de Joode, Anoek A E; Roozendaal, Caroline; van der Leij, Marcel J; Bungener, Laura B; Sanders, Jan Stephan F; Stegeman, Coen A
2014-02-01
In anti-neutrophil cytoplasmic antibodies (ANCA) associated small vessel vasculitis (AAV), rapid testing for ANCA and anti-glomerular basement membrane (GBM) antibodies may be beneficial for therapeutic purpose. We analysed the diagnostic performance of two rapid ANCA and anti-GBM test methods in 260 patients with suspected AAV. Between January 2004 and November 2010, we analysed 260 samples by qualitative Dotblot (Biomedical Diagnostics); retrospective analysis followed with directly coated highly sensitive automated Phadia ELiA and ELiA anti-GBM. Results were related to the final clinical diagnosis and compared with routine capture ELISA. Seventy-four patients had a final diagnosis of AAV (n=62) or anti-GBM disease (n=12). Both Dotblot and ELiA detected all 12 cases of anti-GBM disease; 2 false positive results were found. Dotblot detected ANCA in 56 of 62 AAV patients (sensitivity 90%, NPV 97%), and showed 5 false positives (specificity 97%, PPV 90%). The Phadia ELiA anti-PR3(s) or anti-MPO(s) was positive in 57 of 62 AAV patients (sensitivity 92%, NPV 97%), and had 5 false positives (specificity 97%, PPV 88%). Routine capture ELISA was equally accurate (sensitivity 94%, specificity 97%, PPV 88%, NPV 98%). The Dotblot and Phadia ELiA on anti-GBM, anti-PR3(s) and anti-MPO(s) performed excellently; results were almost identical to routine ELISA. When suspicion of AAV or anti-GBM disease is high and diagnosis is urgently needed, both tests are very powerful for rapid serological diagnosis. Further studies have to confirm the test performances in samples routinely presented for ANCA testing and in follow-up of positive patients. Copyright © 2013 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.
Robles, Lourdes Y; Singh, Satish; Fisichella, Piero Marco
2015-05-15
Despite advances in diagnoses and therapy, esophageal adenocarcinoma remains a highly lethal neoplasm. Hence, a great interest has been placed in detecting early lesions and in the detection of Barrett esophagus (BE). Advanced imaging technologies of the esophagus have then been developed with the aim of improving biopsy sensitivity and detection of preplastic and neoplastic cells. The purpose of this article was to review emerging imaging technologies for esophageal pathology, spectroscopy, confocal laser endomicroscopy (CLE), and optical coherence tomography (OCT). We conducted a PubMed search using the search string "esophagus or esophageal or oesophageal or oesophagus" and "Barrett or esophageal neoplasm" and "spectroscopy or optical spectroscopy" and "confocal laser endomicroscopy" and "confocal microscopy" and "optical coherence tomography." The first and senior author separately reviewed all articles. Our search identified: 19 in vivo studies with spectroscopy that accounted for 1021 patients and 4 ex vivo studies; 14 clinical CLE in vivo studies that accounted for 941 patients and 1 ex vivo study with 13 patients; and 17 clinical OCT in vivo studies that accounted for 773 patients and 2 ex vivo studies. Human studies using spectroscopy had a very high sensitivity and specificity for the detection of BE. CLE showed a high interobserver agreement in diagnosing esophageal pathology and an accuracy of predicting neoplasia. We also found several clinical studies that reported excellent diagnostic sensitivity and specificity for the detection of BE using OCT. Advanced imaging technology for the detection of esophageal lesions is a promising field that aims to improve the detection of early esophageal lesions. Although advancing imaging techniques improve diagnostic sensitivities and specificities, their integration into diagnostic protocols has yet to be perfected. Copyright © 2015 Elsevier Inc. All rights reserved.
How well do vital signs identify children with serious infections in paediatric emergency care?
Thompson, M; Coad, N; Harnden, A; Mayon-White, R; Perera, R; Mant, D
2009-11-01
To determine whether vital signs identify children with serious infections, and to compare their diagnostic value with that of the Manchester triage score (MTS) and National Institute for Health and Clinical Excellence (NICE) traffic light system of clinical risk factors. Prospective cohort of children presenting with suspected acute infection. We recorded vital signs, level of consciousness, activity level, respiratory distress, hydration and MTS category. Paediatric assessment unit at a teaching hospital in England. 700 children (median age 3 years), of whom 357 (51.0%) were referred from primary care, 198 (28.3%) self-referrals and 116 (16.6%) emergency ambulance transfers. Just over half (383 or 54.7%) were admitted. Severity of infection categorised as serious, intermediate, minor or not infection. Children with serious or intermediate infections (n = 313) were significantly more likely than those with minor or no infection (n = 387) to have a temperature >or=39 degrees C, tachycardia, saturations
Broder, Anna; Mowrey, Wenzhu B; Izmirly, Peter; Costenbader, Karen H
2017-04-01
Using American College of Rheumatology (ACR) and Systemic Lupus International Collaborating Clinics (SLICC) criteria for systemic lupus erythematosus (SLE) classification as gold standards, we determined sensitivity, specificity, positive and negative predictive values (PPV and NPV) of having SLE denoted as the primary cause of end-stage renal disease (ESRD) in the US Renal Data System (USRDS). ESRD patients were identified by International Classification of Diseases, Ninth Revision codes in electronic medical records of 1 large tertiary care center, Montefiore Hospital, from 2006 to 2012. Clinical data were extracted and reviewed to establish SLE diagnosis. Data were linked by social security number, name, and date of birth to the USRDS, where primary causes of ESRD were ascertained. Of 7,396 ESRD patients at Montefiore, 97 met ACR/SLICC SLE criteria, and 86 had SLE by record only. Among the 97 SLE patients, the attributed causes of ESRD in the USRDS were 77 SLE and 12 with other causes (unspecified glomerulonephritis, hypertension, scleroderma), and 8 missing. Sensitivity, specificity, PPV, and NPV for SLE in the USRDS were 79%, 99.9%, 93%, and 99.7%, respectively. Of the 60 patients with biopsy-proven lupus nephritis, 44 (73%) had SLE as primary ESRD cause in the USRDS. Attribution of the primary ESRD causes among SLE patients with ACR/SLICC criteria differed by race, ethnicity, and transplant status. The diagnosis of SLE as the primary cause of ESRD in the USRDS has good sensitivity, and excellent specificity, PPV, and NPV. Nationwide access to medical records and biopsy reports may significantly improve sensitivity of SLE diagnosis. © 2016, American College of Rheumatology.
Zhang, Kai; Wang, Ke; Zhu, Xue; Xu, Fei; Xie, Minhao
2017-01-15
MicroRNA (miRNA) has become an important biomarker candidate for cancer diagnosis, prognosis, and therapy. In this study, we have developed a novel fluorescence method for sensitive and specific miRNA detection via duplex specific nuclease (DSN) signal amplification and demonstrated its practical application in biological samples. Malachite green (MG) was employed as a "label-free" signal transducer since fluorescence of MG could be enhanced by 100-fold when MG were binding to a G-quadruplex structure formed within the d(G 2 T) 13 G sequence. The proposed signal amplification strategy is an integrated "biological circuit" designed to initiate a cascade of enzymatic reactions in order to detect, amplify, and measure a specific miRNA sequence by using the isothermal cleavage property of a DSN. The circuit is composed of two molecular switches operating in series: the amplification reaction activated by a specific miRNA and the strand-displacement polymerization reaction designed to initiate molecular beacon-assisted amplification and signal transduction by using MG/G-quadruplex complex. The hsa-miR-141 (miR141) was chosen as a target miRNA because its level specifically abnormal in a wide range of common human cancers including breast, lung, colon, and prostate cancer. The proposed method allowed quantitative sequence-specific detection of miR141 (with a detection limit of 1.03pM) in a dynamic range from 1pM to 10μM, with an excellent ability to discriminate differences in miRNAs. Moreover, the detection assay was applied to quantify miR141 in cancerous cell lysates. On the basis of these findings, we believe that this proposed sensitive and specific assay has great potential as a miRNA quantification method for use in biomedical research and clinical diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.
Cohen, Oren S.; Prohovnik, Isak; Korczyn, Amos D.; Ephraty, Lilach; Nitsan, Zeev; Tsabari, Rakefet; Appel, Shmuel; Rosenmann, Hanna; Kahana, Ester; Chapman, Joab
2011-01-01
Objectives To develop a scale sensitive for the neurological manifestations of Creutzfeldt-Jakob disease (CJD). Methods A 26-item CJD neurological status scale (CJD-NS) was created based on characteristic disease manifestations. Each sign was assigned to one of eight neurological systems to calculate a total scale score (TSS) and a system involvement score (SIS). The scale was administered to 37 CJD patients, 101 healthy first-degree relatives of the patients and 14 elderly patients with Parkinson's disease (PD). Results The mean TSS (±SD) was significantly higher in patients with CJD (13.19±5.63) compared to normal controls (0.41±0.78) and PD patients (9.71±3.05). The mean SIS was also significantly different between the CJD (5.19±1.22) and PD (2.78±1.18 p<0.01) groups reflecting the disseminated nature of neurological involvement in CJD. Using a cutoff of TSS>4 yielded a sensitivity of 97% for CJD, and specificity of 100% against healthy controls. All individual items showed excellent specificity against healthy subjects, but sensitivity was highly variable. Repeat assessments of CJD patients over 3-9 months revealed a time-dependent increase of both the TSS and the SIS reflecting the scale's ability to track disease progression. Conclusions The CJD-NS scale is sensitive to neurological signs and their progression in CJD patients. PMID:21303352
Quek, Kia Fatt; Chua, Chong Beng; Razack, Azad Hassan; Low, Wah Yun; Loh, Chit Sin
2005-01-01
The purpose of the present study was to validate the Mandarin version of the International Prostate Symptom Score (Mand-IPSS) in a Malaysian population. The validity and reliability were studied in patients with lower urinary tract symptoms (LUTS; benign prostatic hyperplasia [BPH] group) and without LUTS (control group). Test-retest methodology was used to assess the reliability while Cronbach alpha was used to assess the internal consistency. Sensitivity to change was used to express the effect size index in the preintervention versus post-intervention score in patients with LUTS who underwent transurethral resection of the prostate. For the control group and BPH group, the internal consistency was excellent and a high degree of internal consistency was observed for all seven items (Cronbach alpha = 0.86-0.98 and 0.90-0.98, respectively). Test-retest correlation coefficients for all items were highly significant. Intraclass correlation coefficient (ICC) was high for the control (ICC = 0.93-0.99) and BPH group (ICC = 0.91-0.99). The sensitivity and specificity showed a high degree of sensitivity and specificity to the effects of treatment. A high degree of significance between baseline and post-treatment scores was observed across all seven items in the BPH group but not in the control group. The Mand-IPSS is a suitable, reliable, valid and sensitive instrument to measure clinical change in the Malaysian population.
A versatile near-infrared asymmetric tricarbocyanine for zinc ion sensing in water.
Menéndez, Guillermo O; López, Cecilia Samaniego; Jares-Erijman, Elizabeth A; Spagnuolo, Carla C
2013-01-01
We have synthesized a near-infrared emissive asymmetric tricarbocyanine conveniently functionalized to improve bioconjugation. The leading structure contains a versatile derivatization point at the meso position for facile radical-nucleophilic aromatic substitution. We have evaluated a DPEN (N,N-di(2-picolyl)ethylendiamine) derivative of this dye as a highly selective sensor for zinc (II) in aqueous medium, which performs in an appropriate sensitivity range for biological studies. The probe was successfully conjugated to a protein-ligand model with high affinity and specificity (biotin-streptavidin technology) rendering an excellent performance of sensing. In a general strategy to obtain sensitive probes combining fluorescent nanoparticles and molecular fluorophores, a preliminary design of a supramolecular assembly derived from the conjugation of the molecular sensor to quantum dots (QDs) was also investigated. The advantages and problems of FRET-based sensors are also discussed. © 2013 The American Society of Photobiology.
Tielen, Deirdre; Wollmann, Lisa
2014-01-01
The social interaction anxiety scale (SIAS) and the social phobia scale (SPS) assess anxiety in social interactions and fear of scrutiny by others. This study examines the psychometric properties of the Dutch versions of the SIAS and SPS using data from a large group of patients with social phobia and a community-based sample. Confirmatory factor analysis revealed that the SIAS is unidimensional, whereas the SPS is comprised of three subscales. The internal consistency of the scales and subscales was good. The concurrent and discriminant validity was supported and the scales were well able to discriminate between patients and community-based respondents. Cut-off values with excellent sensitivity and specificity are presented. Of all self-report measures included, the SPS was the most sensitive for treatment effects. Normative data are provided which can be used to assess whether clinically significant change has occurred in individual patients. PMID:24701560
Deng, Peihong; Xu, Zhifeng; Kuang, Yunfei
2014-08-15
Herein, a novel electrochemical sensor based on an acetylene black paste electrode modified with molecularly imprinted chitosan-graphene composite film for sensitive and selective detection of bisphenol A (BPA) has been developed. Several important parameters controlling the performance of the sensor were investigated and optimised. The imprinted sensor offers a fast response and sensitive BPA quantification. Under the optimal conditions, a linear range from 8.0 nM to 1.0 μM and 1.0 to 20 μM for the detection of BPA was observed with the detection limit of 6.0 nM (S/N=3). Meanwhile, the fabricated sensor showed excellent specific recognition to template molecule among the structural similarities and coexistence substances. Furthermore, this imprinted electrochemical sensor was successfully employed to detect BPA in plastic bottled drinking water and canned beverages. Copyright © 2014 Elsevier Ltd. All rights reserved.
de Beurs, Edwin; Tielen, Deirdre; Wollmann, Lisa
2014-01-01
The social interaction anxiety scale (SIAS) and the social phobia scale (SPS) assess anxiety in social interactions and fear of scrutiny by others. This study examines the psychometric properties of the Dutch versions of the SIAS and SPS using data from a large group of patients with social phobia and a community-based sample. Confirmatory factor analysis revealed that the SIAS is unidimensional, whereas the SPS is comprised of three subscales. The internal consistency of the scales and subscales was good. The concurrent and discriminant validity was supported and the scales were well able to discriminate between patients and community-based respondents. Cut-off values with excellent sensitivity and specificity are presented. Of all self-report measures included, the SPS was the most sensitive for treatment effects. Normative data are provided which can be used to assess whether clinically significant change has occurred in individual patients.
Wu, Bo; Lu, Shu-Ting; Deng, Kai; Yu, Hui; Cui, Can; Zhang, Yang; Wu, Ming; Zhuo, Ren-Xi; Xu, Hai-Bo; Huang, Shi-Wen
2017-01-01
In recent years, there has been increasing interest in developing a multifunctional nanoscale platform for cancer monitoring and chemotherapy. However, there is still a big challenge for current clinic contrast agents to improve their poor tumor selectivity and response. Herein, we report a new kind of Gd complex and folate-coated redox-sensitive lipid-polymer hybrid nanoparticle (Gd-FLPNP) for tumor-targeted magnetic resonance imaging and therapy. Gd-FLPNPs can simultaneously accomplish diagnostic imaging, and specific targeting and controlled release of doxorubicin (DOX). They exhibit good monodispersity, excellent size stability, and a well-defined core-shell structure. Paramagnetic nanoparticles based on gadolinium-diethylenetriaminepentaacetic acid-bis-cetylamine have paramagnetic properties with an approximately two-fold enhancement in the longitudinal relaxivity compared to clinical used Magnevist. For targeted and reduction-sensitive drug delivery, Gd-FLPNPs released DOX faster and enhanced cell uptake in vitro, and exhibited better antitumor effect both in vitro and in vivo.
Current Progress of Nanomaterials in Molecularly Imprinted Electrochemical Sensing.
Zhong, Chunju; Yang, Bin; Jiang, Xinxin; Li, Jianping
2018-01-02
Nanomaterials have received much attention during the past decade because of their excellent optical, electronic, and catalytic properties. Nanomaterials possess high chemical reactivity, also high surface energy. Thus, provide a stable immobilization platform for biomolecules, while preserving their reactivity. Due to the conductive and catalytic properties, nanomaterials can also enhance the sensitivity of molecularly imprinted electrochemical sensors by amplifying the electrode surface, increasing the electron transfer, and catalyzing the electrochemical reactions. Molecularly imprinted polymers that contain specific molecular recognition sites can be designed for a particular target analyte. Incorporating nanomaterials into molecularly imprinted polymers is important because nanomaterials can improve the response signal, increase the sensitivity, and decrease the detection limit of the sensors. This study describes the classification of nanomaterials in molecularly imprinted polymers, their analytical properties, and their applications in the electrochemical sensors. The progress of the research on nanomaterials in molecularly imprinted polymers and the application of nanomaterials in molecularly imprinted polymers is also reviewed.
Pan, Hong-zhi; Yu, Hong- Wei; Wang, Na; Zhang, Ze; Wan, Guang-Cai; Liu, Hao; Guan, Xue; Chang, Dong
2015-01-01
To develop a new electrochemical DNA biosensor for determination of Klebsiella pneumoniae carbapenemase, a highly sensitive and selective electrochemical biosensor for DNA detection was constructed based on a glassy carbon electrode (GCE) modified with gold nanoparticles (Au-nano). The Au-nano/GCE was characterized by scanning electromicroscopy, cyclic voltammetry, and electrochemical impedance spectroscopy. The hybridization detection was measured by differential pulse voltammetry using methylene blue as the hybridization indicator. The dynamic range of detection of the sensor for the target DNA sequences was from 1 × 10(-11) to 1 × 10(-8) M, with an LOD of 1 × 10(-12) M. The DNA biosensor had excellent specificity for distinguishing complementary DNA sequence in the presence of non-complementary and mismatched DNA sequence. The Au-nano/GCE showed significant improvement in electrochemical characteristics, and this biosensor was successfully applied for determination of K. pneumoniae.
[The value of PHI/PCA3 in the early diagnosis of prostate cancer].
Tan, S J; Xu, L W; Xu, Z; Wu, J P; Liang, K; Jia, R P
2016-01-12
To investigate the value of prostate health index (PHI) and prostate cancer gene 3 (PCA3) in the early diagnosis of prostate cancer (PCa). A total of 190 patients with abnormal serum prostate specific antigen (PSA) or abnormal digital rectal examination were enrolled. They were all underwent initial biopsy and 11 of them were also underwent repeated biopsy. In addition, 25 healthy cases (with normal digital rectal examination and PSA<4 ng/ml) were the control group.The PHI and PCA3 were detected by using immunofluorescence and Loop-Mediated Isothermal Amplification (LAMP). The sensitivity and specificity of diagnosis were determined by ROC curve.In addition, the relationship between PHI/PSA and the Gleason score and clinical stage were analyzed. A total of 89 patients were confirmed PCa by Pathological diagnosis. The other 101 patients were diagnosed as benign prostatic hyperplasia (BPH). The sensitivity and specificity of PCA3 test were 85.4% was 92.1%. Area under curve (AUC) of PHI is higher than AUC of PSA (0.727>0.699). The PHI in peripheral blood was positively correlated with Gleason score and clinical stage. The detection of PCA3 and PHI shows excellent detecting effectiveness. Compared with single PSA, the combined detection of PHI and PCA3 improved the diagnostic specificity. It can provide a new method for the early diagnosis in prostate cancer and avoid unnecessary biopsies.
Liu, Pei; Han, Lei; Wang, Fei; Petrenko, Valery A; Liu, Aihua
2016-08-15
Staphylococcus aureus (S. aureus) is one of the most ubiquitous pathogens in public healthcare worldwide. It holds great insterest in establishing robust analytical method for S. aureus. Herein, we report a S. aureus-specific recognition element, isolated from phage monoclone GQTTLTTS, which was selected from f8/8 landscape phage library against S. aureus in a high-throughput way. By functionalizing cysteamine (CS)-stabilized gold nanoparticles (CS-AuNPs) with S. aureus-specific pVIII fusion protein (fusion-pVIII), a bifunctional nanoprobe (CS-AuNPs@fusion-pVIII) for S. aureus was developed. In this strategy, the CS-AuNPs@fusion-pVIII could be induced to aggregate quickly in the presence of target S. aureus, resulting in a rapid colorimetric response of gold nanoparticles. More importantly, the as-designed probe exhibited excellent selectivity over other bacteria. Thus, the CS-AuNPs@fusion-pVIII could be used as the indicator of target S. aureus. This assay can detect as low as 19CFUmL(-1)S. aureus within 30min. Further, this approach can be applicable to detect S. aureus in real water samples. Due to its sensitivity, specificity and rapidness, this proposed method is promising for on-site testing of S. aureus without using any costly instruments. Copyright © 2016 Elsevier B.V. All rights reserved.
Influence of surface states of CuInS2 quantum dots in quantum dots sensitized photo-electrodes
NASA Astrophysics Data System (ADS)
Peng, Zhuoyin; Liu, Yueli; Wu, Lei; Zhao, Yinghan; Chen, Keqiang; Chen, Wen
2016-12-01
Surface states are significant factor for the enhancement of electrochemical performance in CuInS2 quantum dot sensitized photo-electrodes. DDT, OLA, MPA, and S2- ligand capped CuInS2 quantum dot sensitized photo-electrodes are prepared by thermolysis, solvethermal and ligand-exchange processes, respectively, and their optical properties and photoelectrochemical properties are investigated. The S2- ligand enhances the UV-vis absorption and electron-hole separation property as well as the excellent charge transfer performance of the photo-electrodes, which is attributed to the fact that the atomic S2- ligand for the interfacial region of quantum dots may improve the electron transfer rate. These S2--capped CuInS2 quantum dot sensitized photo-electrodes exhibit the excellent photoelectrochemical efficiency and IPCE peak value, which is higher than that of the samples with DDT, OLA and MPA ligands.
Simultaneous detection of multiple biomarkers by means of SERS on polymer nanopillar gold arrays
NASA Astrophysics Data System (ADS)
Morasso, Carlo; Picciolini, Silvia; Mehn, Dora; Pellacani, Paola; Frangolho, Ana; Marchesini, Gerardo; Vanna, Renzo; Gualerzi, Alice; Bedoni, Marzia; Marabelli, Franco; Gramatica, Furio
2016-03-01
The detection of biomarkers by means of Surface Enhanced Raman Spectroscopy (SERS) is foreseen to became a very important tool in the clinical practice because of its excellent sensitivity and potential for the simultaneous detection of multiple biomarkers. In the present paper we describe how it was possible to build a sensor for the detection of genetic biomarkers involved in acute myeloid leukemia. The assay is based on the use of a specifically designed SERS substrate made of a 2D crystal structure of polymeric pillars embedded in a gold layer. This substrate is characterized by good enhancing properties coupled with an excellent homogeneity. The SERS substrate was conjugated with DNA probes complementary to a target sequence and used in a sandwich assay with gold nanoparticles labeled with a second DNA probe and a Raman reporter. The so developed assay allowed the detection of a leukemia biomarker (WT1 gene) and an housekeeping gene with low picomolar sensitivity. At last, we optimized the assay in order to tackle one of the main limitations of SERS based assay: the loss of signal that is observed when the Raman spectra are collected in liquid. Combining a preferential functionalization on the polymeric pillars with a different height of the polymer pillars from the gold layer the assay demonstrated its effectiveness even when measured in buffer.
Papoti, Daniel; Yen, Cecil Chern-Chyi; Mackel, Julie B.; Merkle, Hellmut; Silva, Afonso C.
2014-01-01
Functional Magnetic Resonance Imaging (fMRI) has established itself as the main research tool in neuroscience and brain cognitive research. The common marmoset (Callithrix jacchus) is a non-human primate model of increasing interest in biomedical research. However, commercial MRI coils for marmosets are not generally available. The present work describes the design and construction of a 4-channel receive-only surface RF coil array with excellent signal-to-noise ratio (SNR) specifically optimized for fMRI experiments in awake marmosets in response to somatosensory stimulation. The array was designed as part of a helmet-based head restraint system used to prevent motion during the scans. High SNR was obtained by building the coil array using a thin and flexible substrate glued to the inner surface of the restraint helmet, so as to minimize the distance between the array elements and the somatosensory cortex. Decoupling between coil elements was achieved by partial geometrical overlapping and by connecting them to home-built low input impedance preamplifiers. In vivo images show excellent coverage of the brain cortical surface with high sensitivity near the somatosensory cortex. Embedding the coil elements within the restraint helmet allowed fMRI data in response to somatosensory stimulation to be collected with high sensitivity and reproducibility in conscious, awake marmosets. PMID:23696219
Zhang, Jiulong; Yang, Chunrong; Pan, Shuang; Shi, Menghao; Li, Jie; Hu, Haiyang; Qiao, Mingxi; Chen, Dawei; Zhao, Xiuli
2018-11-01
Mitochondrial-targeting therapy was considered to be a promising approach for the efficient treatment of cancer while positive charge induced nonspecific cytotoxicity severely limits its application. To overcome this drawback, a novel mitochondria targeted conjugate triphenylphosphine-docetaxel (TD) has been synthesized successfully and incorporated it into liposomes (EPSLP/TD), which possessed excellent pH-sensitive characteristic, EphA 10 mediated active targetability as well as mitochondria-targeting capability. EPSLP/TD was characterized to have a small particle size, high-encapsulation efficiency and excellent pH-sensitive characteristic. Compared with DTX-loaded liposomes (EPSLP/DTX), EPSLP/TD possessed higher cytotoxicity against MCF-7 cell line. Mitochondrial-targeting assay demonstrated mitochondria-targeting moiety triphenylphosphine (TPP) could efficiently deliver DTX to mitochondria. Western immunoblotting assay indicated that EPSLP/TD could efficiently deliver antitumor drug to mitochondria and induce cell apoptosis via mitochondria-mediated apoptosis pathway. In vivo antitumor study demonstrated EPSLP/TD owed excellent in vivo antitumor activity. Histological assay demonstrated EPSLP/TD showed strongly apoptosis inducing effect, anti-proliferation effect and anti-angiogenesis effect. This work investigated the potential of hierarchical targeting pH-sensitive liposomes is a suitable carrier to activate mitochondria-mediated apoptosis pathway for cancer therapy.
Evaluation of the HISCL Anti-Treponema pallidum Assay as a Screening Test for Syphilis
An, Jingna; Chen, Qixia; Liu, Qianqian; Rao, Chenli; Li, Dongdong; Wang, Tingting
2015-01-01
The resurgence of syphilis in recent years has become a serious threat to public health worldwide, and the serological detection of specific antibodies against Treponema pallidum remains the most reliable method for laboratory diagnosis of syphilis. This study examined the performance of the recently launched HISCL anti-Treponema pallidum (anti-TP) assay as a screening test for syphilis in a high-volume laboratory. The HISCL anti-TP assay was tested in 300 preselected syphilis-positive samples, 704 fresh syphilis-negative samples, 48 preselected potentially interfering samples, and 30 “borderline” samples and was compared head to head with the commercially available Lumipulse G TP-N. In this study, the HISCL anti-TP assay was in perfect agreement with the applied testing algorithms with an overall agreement of 100%, comparable to that of Lumipulse G TP-N (99.63%). The sensitivity and specificity of the HISCL anti-TP assay were 100% (95% confidence interval [CI], 98.42% to 100%) and 100% (95% CI, 99.37% to 100%), respectively. Considering the excellent ease of use and automation, high throughput, and its favorable sensitivity and specificity, the HISCL anti-TP assay may represent a new choice for syphilis screening in high-volume laboratories. PMID:25972403
Evaluation of the HISCL Anti-Treponema pallidum Assay as a Screening Test for Syphilis.
An, Jingna; Chen, Qixia; Liu, Qianqian; Rao, Chenli; Li, Dongdong; Wang, Tingting; Tao, Chuanmin; Wang, Lanlan
2015-07-01
The resurgence of syphilis in recent years has become a serious threat to public health worldwide, and the serological detection of specific antibodies against Treponema pallidum remains the most reliable method for laboratory diagnosis of syphilis. This study examined the performance of the recently launched HISCL anti-Treponema pallidum (anti-TP) assay as a screening test for syphilis in a high-volume laboratory. The HISCL anti-TP assay was tested in 300 preselected syphilis-positive samples, 704 fresh syphilis-negative samples, 48 preselected potentially interfering samples, and 30 "borderline" samples and was compared head to head with the commercially available Lumipulse G TP-N. In this study, the HISCL anti-TP assay was in perfect agreement with the applied testing algorithms with an overall agreement of 100%, comparable to that of Lumipulse G TP-N (99.63%). The sensitivity and specificity of the HISCL anti-TP assay were 100% (95% confidence interval [CI], 98.42% to 100%) and 100% (95% CI, 99.37% to 100%), respectively. Considering the excellent ease of use and automation, high throughput, and its favorable sensitivity and specificity, the HISCL anti-TP assay may represent a new choice for syphilis screening in high-volume laboratories. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Physical signs of dehydration in the elderly.
Shimizu, Miyuki; Kinoshita, Kensuke; Hattori, Kazuya; Ota, Yoshio; Kanai, Takao; Kobayashi, Hiroyuki; Tokuda, Yasuharu
2012-01-01
Dehydration is a common condition and frequent cause of hospitalization in older people, despite the caregiver's high attention in attempt to avoid its occurrence. In this study, various physical signs were examined as clinical signs of dehydration in elderly. A prospective observational study was conducted in an acute care teaching hospital. Consecutive elderly patients who were admitted to the Department of Medicine were evaluated. Dehydration was defined as a calculated serum osmolality above 295 mOsm/L. The patients diagnosed as dehydrated or not dehydrated were observed for physical signs of dehydration. Data of blood and urine chemistry analysis were also compared between the two groups. A total of 27 elderly patients admitted with acute medical conditions were included in this study. For the physical signs, dry axilla had moderate sensitivity (44%) and excellent specificity (89%) to detect dehydration. Sunken eyes and delayed capillary refill time also showed relatively good specificity (83%). For laboratory data, the mean concentrations of serum sodium of the dehydrated group (146 mEq/L) was significantly higher (p<0.01) than those of the non-dehydrated group (134 mEq/L). Physical signs of dehydration in elderly showed relatively good specificity but poor sensitivity. The evaluation of the axillary moisture could help assess dehydration as well as laboratory data analysis such as serum sodium concentration.
Polythiophene nanofilms for sensitive fluorescence detection of viruses in drinking water.
Wankar, Shashwati; Turner, Nicholas W; Krupadam, Reddithota J
2016-08-15
Molecular imprints of the tobacco necrosis virus (TNV) have been formed within polythiophene nanofilms with an approximate thickness of 200nm. These films have been electrochemically deposited onto conducting Au surfaces. Upon rebinding, the TNV-polythiophene complex changes the fluorescence intensity of the nanofilm. The fluorescence intensity at 410nm was observed to be proportional to the concentration of viruses in the range of 0.1-10ngL(-1) (0.15-15pg) with the lower calculated detection limit of 2.29ngL(-1) (3.4pg). The intensity of the fluorescence emission is not affected by the thickness of the polythiophene film and the nature of TNV specific binding sites. Kinetic data analyses showed that the nanofilm responds to TNV within 2min; and cross-selectivity studies with tobacco mosaic virus (TMV) showed an excellent specificity for the targeted TNV. These binding experiments demonstrate the potential of fluorescence emission for the specific, label free and rapid detection of viruses using nanofilm sensors. Taking into account the lower limit of detection, the fluorescence sensing reported here is reliable, simple to perform, rapid, cost-effective and offers a sensitive analytical method for virus detection in water resources. Copyright © 2016 Elsevier B.V. All rights reserved.
Aptamer-Based Dual-Functional Probe for Rapid and Specific Counting and Imaging of MCF-7 Cells.
Yang, Bin; Chen, Beibei; He, Man; Yin, Xiao; Xu, Chi; Hu, Bin
2018-02-06
Development of multimodal detection technologies for accurate diagnosis of cancer at early stages is in great demand. In this work, we report a novel approach using an aptamer-based dual-functional probe for rapid, sensitive, and specific counting and visualization of MCF-7 cells by inductively coupled plasma-mass spectrometry (ICP-MS) and fluorescence imaging. The probe consists of a recognition unit of aptamer to catch cancer cells specifically, a fluorescent dye (FAM) moiety for fluorescence resonance energy transfer (FRET)-based "off-on" fluorescence imaging as well as gold nanoparticles (Au NPs) tag for both ICP-MS quantification and fluorescence quenching. Due to the signal amplification effect and low spectral interference of Au NPs in ICP-MS, an excellent linearity and sensitivity were achieved. Accordingly, a limit of detection of 81 MCF-7 cells and a relative standard deviation of 5.6% (800 cells, n = 7) were obtained. The dynamic linear range was 2 × 10 2 to 1.2 × 10 4 cells, and the recoveries in human whole blood were in the range of 98-110%. Overall, the established method provides quantitative and visualized information on MCF-7 cells with a simple and rapid process and paves the way for a promising strategy for biomedical research and clinical diagnostics.
Feehan, Lynne M; Goldsmith, Charles H; Leung, April Y F; Li, Linda C
Purpose: To compare the ability of SenseWear Mini (SWm) and Actigraph GT3X (AG 3 ) accelerometers to differentiate between healthy adults' observed sedentary and light activities in a laboratory setting. Methods: The 22 participants (15 women, 7 men), ages 19 to 72 years, wore SWm and AG 3 monitors and performed five sedentary and four light activities for 5 minutes each while observed in a laboratory setting. Performance was examined through comparisons of accuracy, sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios. Correct identification of both types of activities was examined using area under the receiver operating characteristic curve (AUC). Results: Both monitors demonstrated excellent ability to identify sedentary activities (sensitivity>0.89). The SWm monitor was better at identifying light activities (specificity 0.61-0.71) than the AG 3 monitor (specificity 0.27-0.47) and thus also showed a greater ability to correctly identify both sedentary and light activities (SWm AUC 0.84; AG 3 AUC 0.62-0.73). Conclusions: SWm may be a more suitable monitor for detecting time spent in sedentary and light-intensity activities. This finding has clinical and research relevance for evaluation of time spent in lower intensity physical activities by sedentary adults.
Chen, Xueping; Wang, Li; Sheng, Shangchun; Wang, Teng; Yang, Juan; Xie, Guoming; Feng, Wenli
2015-08-19
This article described a novel method by coupling a universal DNA circuit with graphene sheets/polyaniline/AuNPs nanocomposites (GS/PANI/AuNPs) for highly sensitive and specific detection of BCR/ABL fusion gene (bcr/abl) in chronic myeloid leukemia (CML). DNA circuit known as catalyzed hairpin assembly (CHA) is enzyme-free and can be simply operated to achieve exponential amplification, which has been widely employed in biosensing. However, application of CHA has been hindered by the need of specially redesigned sequences for each single-stranded DNA input. Herein, a transducer hairpin (HP) was designed to obtain a universal DNA circuit with favorable signal-to-background ratio. To further improve signal amplification, GS/PANI/AuNPs with excellent conductivity and enlarged effective area were introduced into this DNA circuit. Consequently, by combining the advantages of CHA and GS/PANI/AuNPs, bcr/abl could be detected in a linear range from 10 pM to 20 nM with a detection limit of 1.05 pM. Moreover, this protocol showed excellent specificity, good stability and was successfully applied for the detection of real sample, which demonstrated its great potential in clinical application. Copyright © 2015 Elsevier B.V. All rights reserved.
Label-free signal-on aptasensor for sensitive electrochemical detection of arsenite.
Cui, Lin; Wu, Jie; Ju, Huangxian
2016-05-15
A signal-on aptasensor was fabricated for highly sensitive and selective electrochemical detection of arsenite with a label-free Ars-3 aptamer self-assembled on a screen-printed carbon electrode (SPCE) via Au-S bond. The Ars-3 aptamer could adsorb cationic polydiallyldimethylammonium (PDDA) via electrostatic interaction to repel other cationic species. In the presence of arsenite, the change of Ars-3 conformation due to the formation of Ars-3/arsenite complex led to less adsorption of PDDA, and the complex could adsorb more positively charged [Ru(NH3)6](3+) as an electrochemically active indicator on the aptasensor surface, which produced a sensitive "turn-on" response. The target-induced structure switching could be used for sensitive detection of arsenite with a linear range from 0.2 nM to 100 nM and a detection limit down to 0.15 nM. Benefiting from Ars-3 aptamer, the proposed system exhibited excellent specificity against other heavy metal ions. The SPCE-based aptasensor exhibited the advantages of low cost and simple fabrication, providing potential application of arsenite detection in environment. Copyright © 2016 Elsevier B.V. All rights reserved.
Bencsik, Martin; Al-Rwaili, Amgad; Morris, Robert; Fairhurst, David J; Mundell, Victoria; Cave, Gareth; McKendry, Jonathan; Evans, Stephen
2013-11-01
The direct in-vivo measurement of fluid pressure cannot be achieved with MRI unless it is done with the contribution of a contrast agent. No such contrast agents are currently available commercially, whilst those demonstrated previously only produced qualitative results due to their broad size distribution. Our aim is to quantitate then model the MR sensitivity to the presence of quasi-monodisperse microbubble populations. Lipid stabilised microbubble populations with mean radius 1.2 ± 0.8 μm have been produced by mechanical agitation. Contrast agents with increasing volume fraction of bubbles up to 4% were formed and the contribution the bubbles bring to the relaxation rate was quantitated. A periodic pressure change was also continuously applied to the same contrast agent, until MR signal changes were only due to bubble radius change and not due to a change in bubble density. The MR data compared favourably with the prediction of an improved numerical simulation. An excellent MR sensitivity of 23 % bar(-1) has been demonstrated. This work opens up the possibility of generating microbubble preparations tailored to specific applications with optimised MR sensitivity, in particular MRI based in-vivo manometry. Copyright © 2012 Wiley Periodicals, Inc.
Design enhancement tools in MSC/NASTRAN
NASA Technical Reports Server (NTRS)
Wallerstein, D. V.
1984-01-01
Design sensitivity is the calculation of derivatives of constraint functions with respect to design variables. While a knowledge of these derivatives is useful in its own right, the derivatives are required in many efficient optimization methods. Constraint derivatives are also required in some reanalysis methods. It is shown where the sensitivity coefficients fit into the scheme of a basic organization of an optimization procedure. The analyzer is to be taken as MSC/NASTRAN. The terminator program monitors the termination criteria and ends the optimization procedure when the criteria are satisfied. This program can reside in several plances: in the optimizer itself, in a user written code, or as part of the MSC/EOS (Engineering Operating System) MSC/EOS currently under development. Since several excellent optimization codes exist and since they require such very specialized technical knowledge, the optimizer under the new MSC/EOS is considered to be selected and supplied by the user to meet his specific needs and preferences. The one exception to this is a fully stressed design (FSD) based on simple scaling. The gradients are currently supplied by various design sensitivity options now existing in MSC/NASTRAN's design sensitivity analysis (DSA).
Wang, Yunyun; Wang, Jixiang; Cheng, Rujia; Sun, Lin; Dai, Xiaohui; Yan, Yongsheng
2018-04-01
An imprinted fluorescent sensor was fabricated based on SiO 2 nanoparticles encapsulated with a molecularly imprinted polymer containing allyl fluorescein. High fluorine cypermethirin as template molecules, methyl methacrylate as functional monomer, and allyl fluorescein as optical materials synthesized a core-shell fluorescent molecular imprinted sensor, which showed a high and rapid sensitivity and selectivity for the detection of τ-fluvalinate. The sensor presented appreciable sensitivity with a limit of 13.251 nM, rapid detection that reached to equilibrium within 3 min, great linear relationship in the relevant concentration range from 0 to 150 nM, and excellent selectivity over structural analogues. In addition, the fluorescent sensor demonstrated desirable regeneration ability (eight cycling operations). The molecularly imprinted polymers ensured specificity, while the fluorescent dyes provided the stabile sensitivity. Finally, an effective application of the sensor was implemented by the detection of τ-fluvalinate in real samples from vodka. The molecularly imprinted fluorescent sensor showed a promising potential in environmental monitoring and food safety. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
[Exploring a non-inflammatory clinical breast mass: Clinical practice guidelines].
Legendre, G; Guilhen, N; Nadeau, C; Brossard, A; Fauvet, R
2015-12-01
The aim of the study was to assess the diagnostic value of physical examination, radiologic explorations and percutaneous procedures of the breast in the exploration of a non-inflammatory palpable mass, in order to propose guidelines. A systematic literature review was conducted in the Medline and Cochrane library databases. International guidelines in French and English language were also consulted until April 30th 2015. Physical examination of a non-inflammatory palpable breast mass is not sufficient to eliminate a breast cancer (LE2). Mammography alone has a sensitivity between 70 and 95% for the diagnosis of breast cancer (LE3). Echography alone has a sensitivity of 98 to 100% for the diagnosis of breast cancer (LE2). The core needle biopsy has a better sensitivity and specificity than the fine-needle aspiration for breast cancer diagnosis (LE2). The association of mammography and 2D echography presents excellent sensitivity and negative predictive value (close to 100 %) to exclude a breast cancer (LE3). A double evaluation using mammography and echography is recommended in the exploration of a non-inflammatory palpable breast mass (grade B). Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Tan, Dezhi; Zhang, Wenjin; Wang, Xiaofan; Koirala, Sandhaya; Miyauchi, Yuhei; Matsuda, Kazunari
2017-08-31
Layered materials, such as graphene, transition metal dichalcogenides and black phosphorene, have been established rapidly as intriguing building blocks for optoelectronic devices. Here, we introduce highly polarization sensitive, broadband, and high-temperature-operation photodetectors based on multilayer germanium sulfide (GeS). The GeS photodetector shows a high photoresponsivity of about 6.8 × 10 3 A W -1 , an extremely high specific detectivity of 5.6 × 10 14 Jones, and broad spectral response in the wavelength range of 300-800 nm. More importantly, the GeS photodetector has high polarization sensitivity to incident linearly polarized light, which provides another degree of freedom for photodetectors. Tremendously enhanced photoresponsivity is observed with a temperature increase, and high responsivity is achievable at least up to 423 K. The establishment of larger photoinduced reduction of the Schottky barrier height will be significant for the investigation of the photoresponse mechanism of 2D layered material-based photodetectors. These attributes of high photocurrent generation in a wide temperature range, broad spectral response, and polarization sensitivity coupled with environmental stability indicate that the proposed GeS photodetector is very suitable for optoelectronic applications.
The Personal Experience of LGBT Patients with Cancer.
Carr, Ellen
2018-02-01
To capture the perspectives from lesbian, gay, bisexual and transgender (LGBT) individuals diagnosed treated for cancer. Four LGBT individuals diagnosed and treated for cancer. Care for the LGBT patient is based on sensitivity and awareness to LGBT issues and concerns. Nurses caring for the LGBT cancer patient provide that care in a context of awareness and sensitivity. The nurse's approach to LGBT patient and family care is based on open communication, establishing trusting relationships and honoring the patient's preferences. Excellent oncology nursing care for LGBT patients is excellent oncology nursing care. Copyright © 2017 Elsevier Inc. All rights reserved.
2010-01-01
Background For large scale epidemiological studies clinical assessments and radiographs can be impractical and expensive to apply to more than just a sample of the population examined. The study objectives were to develop and validate two novel instruments for self-reported knee malalignment and foot rotation suitable for use in questionnaire studies of knee pain and osteoarthritis. Methods Two sets of line drawings were developed using similar methodology. Each instrument consisted of an explanatory question followed by a set of drawings showing straight alignment, then two each at 7.5° angulation and 15° angulation in the varus/valgus (knee) and inward/outward (foot) directions. Forty one participants undertaking a community study completed the instruments on two occasions. Participants were assessed once by a blinded expert clinical observer with demonstrated excellent reproducibility. Validity was assessed by sensitivity, specificity and likelihood ratio (LR) using the observer as the reference standard. Reliability was assessed using weighted kappa (κ). Knee malalignment was measured on 400 knee radiographs. General linear model was used to assess for the presence of a linear increase in knee alignment angle (measured medially) from self-reported severe varus to mild varus, straight, mild valgus and severe valgus deformity. Results Observer reproducibility (κ) was 0.89 and 0.81 for the knee malalignment and foot rotation instruments respectively. Self-reported participant reproducibility was also good for the knee (κ 0.73) and foot (κ 0.87) instruments. Validity was excellent for the knee malalignment instrument, with a sensitivity of 0.74 (95%CI 0.54, 0.93) and specificity of 0.97 (95%CI 0.94, 1.00). Similarly the foot rotation instrument was also found to have high sensitivity (0.92, 95%CI 0.83, 1.01) and specificity (0.96, 95%CI 0.93, 1.00). The knee alignment angle increased progressively from self reported severe varus to mild varus, straight, mild valgus and severe valgus knee malalignment (ptrend <0.001). Conclusions The two novel instruments appear to provide a valid and reliable assessment of self-reported knee malalignment and foot rotation, and may have a practical use in epidemiological studies. PMID:20565825
Osterhoff, G; Amiri, S; Unno, F; Dodd, A; Guy, P; O'Brien, P J; Lefaivre, K A
2015-08-01
Minimal-invasive placement of screws into the posterior column of the acetabulum (PC) is challenging. Due to the saddle-shaped curvature of the medial cortical border of the PC, the standard fluoroscopic views of the pelvis cannot provide the desired safety during screw insertion. The aim of this study was to define a view tangentially to the medial cortex of the PC and to evaluate its accuracy and inter-observer reproducibility. Radio-dense markers on the medial cortex of the PC along the axis of a PC screw were brought in line and landmarks of the new "Down the PC" view were determined. Kirschner wires were placed into the PC of a pelvis composite model and five pelvic cadaver specimens in a total of 34 different correct and incorrect positions. Based on either only the "Down the PC" view, only the standard views, or a combination of both, three fellowship-trained orthopaedic surgeons had to decide if the inserted wires were in bone in the posterior column or had exited cortex, and if they penetrated the acetabulum. Sensitivity, specificity, and the intra-class correlation coefficient were calculated. A view using three radiographic landmarks (pelvic brim, medial cortical wall of the body of the ischium, ischial spine) was found. Sensitivity and specificity to detect perforation out of the bone were 1.00 and 0.97 for the "Down the PC" view, 0.46 and 0.97 if only the standard views were used, and 1.00 and 0.95 for a combination of both. Sensitivity and specificity to detect intra-articular wire placement were 1.00 and 0.96 for the "Down the PC" view, 0.72 and 0.95 if only the standard views were used, and 0.94 and 0.99 for a combination of both. Inter-observer agreement using only the "Down the PC" view was excellent with an ICC of 0.92 for perforation and ICC of 0.82 for intra-articular wire placement. The "Down the PC" view is a useful addendum in the orthopaedic trauma surgeon's tool box. Using simple landmarks, it is easily to reproduce and thereby shows excellent accuracy and inter-observer agreement in order to detect medial perforation or intra-articular implant position. Copyright © 2015 Elsevier Ltd. All rights reserved.
Rapid Characterization of Microorganisms by Mass Spectrometry—What Can Be Learned and How?
NASA Astrophysics Data System (ADS)
Fenselau, Catherine C.
2013-08-01
Strategies for the rapid and reliable analysis of microorganisms have been sought to meet national needs in defense, homeland security, space exploration, food and water safety, and clinical diagnosis. Mass spectrometry has long been a candidate technique because it is extremely rapid and can provide highly specific information. It has excellent sensitivity. Molecular and fragment ion masses provide detailed fingerprints, which can also be interpreted. Mass spectrometry is also a broad band method—everything has a mass—and it is automatable. Mass spectrometry is a physiochemical method that is orthogonal and complementary to biochemical and morphological methods used to characterize microorganisms.
Rapid characterization of microorganisms by mass spectrometry--what can be learned and how?
Fenselau, Catherine C
2013-08-01
Strategies for the rapid and reliable analysis of microorganisms have been sought to meet national needs in defense, homeland security, space exploration, food and water safety, and clinical diagnosis. Mass spectrometry has long been a candidate technique because it is extremely rapid and can provide highly specific information. It has excellent sensitivity. Molecular and fragment ion masses provide detailed fingerprints, which can also be interpreted. Mass spectrometry is also a broad band method--everything has a mass--and it is automatable. Mass spectrometry is a physiochemical method that is orthogonal and complementary to biochemical and morphological methods used to characterize microorganisms.
Yin, Feifei; Chan, Jasper Fuk-Woo; Zhu, Qixuan; Fu, Ruijia; Chen, Jonathan Hon-Kwan; Choi, Garnet Kwan-Yue; Tee, Kah-Meng; Li, Lihua; Qian, Shiuyun; Yam, Wing-Cheong; Lu, Gang; Yuen, Kwok-Yung
2017-04-01
Rapid and accurate diagnostic assays with simultaneous microbial identification and drug resistance detection are essential for optimising treatment and control of tuberculosis. We developed a novel multiplex (TRIOL, Tuberculosis-Rifampicin-Isoniazid-Ofloxacin-Luminex) assay using the Luminex xMAP system that simultaneously identifies Mycobacterium tuberculosis and detects resistance to first-line and second-line anti-tuberculous drugs, and compared its performance with that by PCR sequencing, using phenotypic drug susceptibility testing as the gold standard. Identification of M. tuberculosis by the TRIOL assay was highly sensitive (100%) and specific (100%). The overall drug-specific specificities were excellent (100%). The overall sensitivity of the TRIOL assay was lower than that of the PCR-sequencing assays (72.4% vs 82.8%) because of a lower sensitivity of detecting rifampicin resistance (71.4% vs 92.9%). The sensitivity of detecting isoniazid and ofloxacin resistance was as good as the PCR-sequencing assays. Importantly, the TRIOL assay did not miss any mutations that were included in the assay. All of the resistant isolates that were missed had uncommon mutations or unknown resistance mechanisms that were not included in the assay. The TRIOL assay has higher throughput, lower cost and is less labour intensive than the PCR-sequencing assays. The TRIOL assay is advantageous in having the capability to detect resistance to multiple drugs and an open-architecture system that allows addition of more specific primers to detect uncommon mutations. Inclusion of additional primers for the identification of non-tuberculous mycobacteria, spoligotyping and improvement of rifampicin resistance detection would enhance the use of the TRIOL assay in future clinical and epidemiological studies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Poljak, Mario; Ostrbenk, Anja; Seme, Katja; Ucakar, Veronika; Hillemanns, Peter; Bokal, Eda Vrtacnik; Jancar, Nina; Klavs, Irena
2011-05-01
The clinical performance of the Abbott RealTime High Risk HPV (human papillomavirus) test (RealTime) and that of the Hybrid Capture 2 HPV DNA test (hc2) were prospectively compared in the population-based cervical cancer screening setting. In women >30 years old (n = 3,129), the clinical sensitivity of RealTime for detection of cervical intraepithelial neoplasia of grade 2 (CIN2) or worse (38 cases) and its clinical specificity for lesions of less than CIN2 (3,091 controls) were 100% and 93.3%, respectively, and those of hc2 were 97.4% and 91.8%, respectively. A noninferiority score test showed that the clinical specificity (P < 0.0001) and clinical sensitivity (P = 0.011) of RealTime were noninferior to those of hc2 at the recommended thresholds of 98% and 90%. In the total study population (women 20 to 64 years old; n = 4,432; 57 cases, 4,375 controls), the clinical sensitivity and specificity of RealTime were 98.2% and 89.5%, and those of hc2 were 94.7% and 87.7%, respectively. The analytical sensitivity and analytical specificity of RealTime in detecting targeted HPV types evaluated with the largest sample collection to date (4,479 samples) were 94.8% and 99.8%, and those of hc2 were 93.4% and 97.8%, respectively. Excellent analytical agreement between the two assays was obtained (kappa value, 0.84), while the analytical accuracy of RealTime was significantly higher than that of hc2. RealTime demonstrated high intralaboratory reproducibility and interlaboratory agreement with 500 samples retested 61 to 226 days after initial testing in two different laboratories. RealTime can be considered to be a reliable and robust HPV assay clinically comparable to hc2 for the detection of CIN2+ lesions in a population-based cervical cancer screening setting.
Tomero, Eva; Mulero, Juan; de Miguel, Eugenio; Fernández-Espartero, Cruz; Gobbo, Milena; Descalzo, Miguel A; Collantes-Estévez, Eduardo; Zarco, Pedro; Muñoz-Fernández, Santiago; Carmona, Loreto
2014-02-01
The objective of this study was to analyse the performance of the Assessment of SpondyloArthritis International Society (ASAS) criteria for the classification of SpA in early SpA clinics. We used a cross-sectional study of patients referred to early SpA units within the ESPERANZA programme (a Spanish nationwide health management programme designed to provide excellence in diagnosis and care for early SpA). Patients were eligible if they were <45 years of age and had any of the following: (i) a 2-year history of inflammatory back pain; (ii) back or joint pain with psoriasis, anterior uveitis, radiographic sacroiliitis, family history of SpA or positive HLA-B27; or (iii) asymmetric arthritis. We excluded patients for whom imaging (X-rays/MRI) or HLA-B27 results were not available. We analysed the performance (sensitivity and specificity) of different classification criteria sets, taking the rheumatologist's opinion as the gold standard. The analysis included 775 patients [mean age 33 (s.d. 7) years; 55% men; mean duration of symptoms 11 (s.d. 6) months]; SpA was diagnosed in 538 patients (69.5%). A total of 274 (67.9%) patients with chronic back pain met the ASAS axial criteria, 76 (56.3%) patients with arthritis but not chronic back pain fulfilled the ASAS criteria for peripheral SpA and 350 (65.1%) fulfilled all the ASAS criteria. The sensitivity and specificity of the ASAS criteria set were 65% and 93%, respectively (axial criteria: sensitivity 68%, specificity 95%). The sensitivity and specificity for the ESSG and Amor criteria were 58% and 90% and 59% and 86%, respectively. Despite performing better than the Amor or ESSG criteria, the ASAS criteria may be limited to detection of early forms, particularly in populations in which MRI is not extensively available or in populations with a low prevalence of HLA-B27.
Pelizza, Lorenzo; Raballo, Andrea; Semrov, Enrico; Chiri, Luigi Rocco; Azzali, Silvia; Scazza, Ilaria; Garlassi, Sara; Paterlini, Federica; Fontana, Francesca; Favazzo, Rosanna; Pensieri, Luana; Fabiani, Michela; Cioncolini, Leonardo; Pupo, Simona
2017-07-26
To establish the concordant validity of the "Checklist per la Valutazione dell'Esordio Psicotico" (CVEP) in an Italian help-seeking population. The CVEP is the Italian adaptation of the "early detection Primary Care Checklist," a 20-item tool specifically designed to assist primary care practitioners in identifying young people in the early stages of psychosis. The checklist was completed by the referring practitioners of 168 young people referred to the "Reggio Emilia At Risk Mental States" Project, an early detection infrastructure developed under the aegis of the Regional Project on Early Detection of Psychosis in the Reggio Emilia Department of Mental Health. The concordant validity of the CVEP was established by comparing screen results with the outcome of the "Comprehensive Assessment of At Risk Mental States" (CAARMS), a gold standard assessment for identifying young people who may be at risk of developing psychosis. The simple checklist as originally conceived had excellent sensitivity (98%), but lower specificity (58%). Using only a CVEP total score of 20 or above as cut-off, the tool showed a slightly lower sensitivity (93%) with a substantial improvement in specificity (87%). Simple cross-tabulations of the individual CVEP item scores against CAARMS outcome to identify the more discriminant item in terms of sensitivity and specificity were carried out. In comparison to other, much longer, screening tools, the CVEP performed well to identify young people in the early stages of psychosis. Therefore, the CVEP is well suited to optimize appropriate referrals to specialist services, building on the skills and knowledge already available in primary care settings. © 2017 John Wiley & Sons Australia, Ltd.
Vrooman, H A; Maliepaard, C; van der Linden, L P; Jessurun, E R; Ludwig, J W; Plokker, H W; Schalij, M J; Weeda, H W; Laufer, J L; Huysmans, H A; Reiber, J H
1997-09-01
The authors developed an analytic software package for the objective and reproducible assessment of a single leg separation (SLS) in the outlet strut of Björk-Shiley convexoconcave (BSCC) prosthetic heart valves. The radiographic cinefilm recordings of 18 phantom valves (12 intact and 6 SLS) and of 43 patient valves were acquired. After digitization of regions of interest in a cineframe, several processing steps were carried out to obtain a one-dimensional corrected and averaged density profile along the central axis of each strut leg. To characterize the degree of possible separation, two quantitative measures were introduced: the normalized pit depth (NPD) and the depth-sigma ratio (DSR). The group of 43 patient studies was divided into a learning set (25 patients) and a test set (18 patients). All phantom valves with an SLS were detected (sensitivity, 100%) at a specificity of 100%. The threshold values for the NPD and the DSR to decide whether a fracture was present or not were 3.6 and 2.5, respectively. On the basis of the visual interpretations of the 25 patient studies (learning set) by an expert panel, it was concluded that none of the patients had an SLS. To achieve a 100% specificity by quantitative analysis, the threshold values for the NPD and the DSR were set at 5.8 and 2.5, respectively, for the patient data. Based on these threshold values, the analysis of patient data from the test set resulted in one false-negative detection and three false-positive detections. An analytic software package for the detection of an SLS was developed. Phantom data showed excellent sensitivity (100%) and specificity (100%). Further research and software development is needed to increase the sensitivity and specificity for patient data.
Evaluation of FlaB1, FlaB2, FlaB3, and Tp0463 of Treponema pallidum for serodiagnosis of syphilis.
Jiang, Chuanhao; Xiao, Jinhong; Xie, Yafeng; Xiao, Yongjian; Wang, Chuan; Kuang, Xingxing; Xu, Man; Li, Ranhui; Zeng, Tiebing; Liu, Shuanquan; Yu, Jian; Zhao, Feijun; Wu, Yimou
2016-02-01
Syphilis is a multistage disease caused by the invasive spirochete Treponema pallidum subsp. pallidum, and accurate diagnosis is important for the prevention and treatment of syphilis. Here, to identify appropriate diagnostic antigens for serodiagnosis of syphilis, 6 recombinant proteins were expressed in Escherichia coli and purified, including flagellins (FlaB1 [Tp0868], FlaB2 [Tp0792], and FlaB3 [Tp0870]), Tp0463, Tp0751, and Tp1038. The sensitivities were determined by screening sera from individuals with primary (n=82), secondary (n=115), latent (n=105), and congenital (n=65) syphilis. The specificities were determined by screening sera from uninfected controls (n=30) and potentially cross-reactive infections including Lyme disease (n=30), leptospirosis (n=5), and hepatitis B (n=30). Our data showed that FlaB1, FlaB2, FlaB3, Tp0463, and Tp1038 exhibited higher overall sensitivities and specificities for detecting IgG antibody, with 95.4% and 98.9%, 92.6% and 95.8%, 95.1% and 95.8%, 92.6% and 97.9%, and 95.9% and 98.9%, respectively. In contrast, Tp0751 demonstrated only an overall sensitivity of 39.2%. For comparison, the sensitivity and specificity of Architect Syphilis TP were determined to be 98.1% and 93.7%, respectively. In addition, FlaB1, FlaB2, FlaB3, and Tp0463 demonstrated excellent performance for detecting IgM antibody in primary and congenital syphilis, with sensitivities of 76.8% and 83.1%, 72.0% and 87.7%, 74.4% and 89.2%, and 64.6% and 75.3%, respectively. These results indicate that FlaB1, FlaB2, FlaB3, and Tp0463 could be as novel diagnostic candidates for serodiagnosis of syphilis. Copyright © 2016 Elsevier Inc. All rights reserved.
Antibody conjugated glycine doped polyaniline nanofilms as efficient biosensor for atrazine
NASA Astrophysics Data System (ADS)
Bhardwaj, Sanjeev K.; Sharma, Amit L.; Kim, Ki-Hyun; Deep, Akash
2017-12-01
Atrazine is an important member of triazine family of pesticides. The development of its detection methods gained great attention due to the potential health risks associated with its contamination in various media including water, soil, and food. The contamination of atrazine in drinking water beyond the legal permissible limit of EPA (e.g. 3 ng ml-1) may cause various damages to living organisms (e.g. heart, urinary, and limb defects). In this research, we discuss the potential significance of a highly sensitive conductometric immunosensor for sensing the atrazine pesticide. To this end, electrochemical assembly of glycine doped polyaniline (PAni) nanofilms on silicon (Si) substrate was built and modified further with anti-atrazine antibodies. The herein developed immunosensor offered highly sensitive detection of atrazine with a low detection limit of 0.07 ng ml-1. The proposed biosensor was simple in design with excellent performance in terms of its sensitivity, stability and specificity. Highlights •Glycine doped PAni nanofilms have been electropolymerized on Silicon substrates. •Functionality of the above thin films provides opportunity to develop an immunosensing platform. •Highly sensitive and specific detection of atrazine has been realized over a wide concentration range with a LOD of 0.07 ng ml-1. Novelty statement Atrazine is a widely used pesticide in the agriculture sector. It is highly recommended to develop simple biosensing systems for enabling the prospect of routine monitoring. The present research for the first time proposes the design of a glycine doped PAni based simple and highly effective biosensor for the atrazine pesticide. The doping of glycine has easily generated functional groups on the nano-PAni material for further convenient immobilization of anti-atrazine antibodies. The proposed sensor can be highlighted with advantages like ease of fabrication, use of environment friendly functionalization agent, specificity, wide linearity, and good sensitivity with enhanced viability.
Magnetic resonance imaging of breast implants.
Shah, Mala; Tanna, Neil; Margolies, Laurie
2014-12-01
Silicone breast implants have significantly evolved since their introduction half a century ago, yet implant rupture remains a common and expected complication, especially in patients with earlier-generation implants. Magnetic resonance imaging is the primary modality for assessing the integrity of silicone implants and has excellent sensitivity and specificity, and the Food and Drug Administration currently recommends periodic magnetic resonance imaging screening for silent silicone breast implant rupture. Familiarity with the types of silicone implants and potential complications is essential for the radiologist. Signs of intracapsular rupture include the noose, droplet, subcapsular line, and linguine signs. Signs of extracapsular rupture include herniation of silicone with a capsular defect and extruded silicone material. Specific sequences including water and silicone suppression are essential for distinguishing rupture from other pathologies and artifacts. Magnetic resonance imaging provides valuable information about the integrity of silicone implants and associated complications.
Grant, A C; Thiagarajah, M C; Sathian, K
2000-02-01
It is not clear whether the blind are generally superior to the sighted on measures of tactile sensitivity or whether they excel only on certain tests owing to the specifics of their tactile experience. We compared the discrimination performance of blind Braille readers and age-matched sighted subjects on three tactile tasks using precisely specified stimuli. Initially, the blind significantly outperformed the sighted at a hyperacuity task using Braille-like dot patterns, although, with practice, both groups performed equally well. On two other tasks, hyperacute discrimination of gratings that differed in ridge width and spatial-acuity-dependent discrimination of grating orientation, the performance of the blind did not differ significantly from that of sighted subjects. These results probably reflect the specificity of perceptual learning due to Braille-reading experience.
Validation of antibiotic residue tests for dairy goats.
Zeng, S S; Hart, S; Escobar, E N; Tesfai, K
1998-03-01
The SNAP test, LacTek test (B-L and CEF), Charm Bacillus sterothermophilus var. calidolactis disk assay (BsDA), and Charm II Tablet Beta-lactam sequential test were validated using antibiotic-fortified and -incurred goat milk following the protocol for test kit validations of the U.S. Food and Drug Administration Center for Veterinary Medicine. SNAP, Charm BsDA, and Charm II Tablet Sequential tests were sensitive and reliable in detecting antibiotic residues in goat milk. All three assays showed greater than 90% sensitivity and specificity at tolerance and detection levels. However, caution should be taken in interpreting test results at detection levels. Because of the high sensitivity of these three tests, false-violative results could be obtained in goat milk containing antibiotic residues below the tolerance level. Goat milk testing positive by these tests must be confirmed using a more sophisticated methodology, such as high-performance liquid chromatography, before the milk is condemned. LacTek B-L test did not detect several antibiotics, including penicillin G, in goat milk at tolerance levels. However, LacTek CEF was excellent in detecting ceftiofur residue in goat milk.
Su, Jiao; Zhang, Haijie; Jiang, Bingying; Zheng, Huzhi; Chai, Yaqin; Yuan, Ruo; Xiang, Yun
2011-11-15
We report an ultrasensitive electrochemical approach for the detection of uropathogen sequence-specific DNA target. The sensing strategy involves a dual signal amplification process, which combines the signal enhancement by the enzymatic target recycling technique with the sensitivity improvement by the quantum dot (QD) layer-by-layer (LBL) assembled labels. The enzyme-based catalytic target DNA recycling process results in the use of each target DNA sequence for multiple times and leads to direct amplification of the analytical signal. Moreover, the LBL assembled QD labels can further enhance the sensitivity of the sensing system. The coupling of these two effective signal amplification strategies thus leads to low femtomolar (5fM) detection of the target DNA sequences. The proposed strategy also shows excellent discrimination between the target DNA and the single-base mismatch sequences. The advantageous intrinsic sequence-independent property of exonuclease III over other sequence-dependent enzymes makes our new dual signal amplification system a general sensing platform for monitoring ultralow level of various types of target DNA sequences. Copyright © 2011 Elsevier B.V. All rights reserved.
Pan, Hong-zhi; Yu, Hong-wei; Wang, Na; Zhang, Ze; Wan, Guang-cai; Liu, Hao; Guan, Xue; Chang, Dong
2015-11-20
We describe the fabrication of a sensitive electrochemical DNA biosensor for determination of Klebsiella pneumoniae carbapenemase (KPC). The highly sensitive and selective electrochemical biosensor for DNA detection was constructed based on a glassy carbon electrode (GCE) modified with gold nanoparticles (Au-NPs) and graphene (Gr). Then Au-NPs/Gr/GCE was characterized by scanning electro microscope (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The hybridization detection was measured by diffierential pulse voltammetry (DPV) using methylene blue (MB) as the hybridization indicator. The dynamic range of detection of the sensor for the target DNA sequences was from 1 × 10(-12) to 1 × 10(-7)mol/L, with a detection limit of 2 × 10(-13)mol/L. The DNA biosensor had excellent specificity for distinguishing complementary DNA sequence in the presence of non-complementary and mismatched DNA sequence. The results demonstrated that the Au-NPs/Gr nanocomposite was a promising substrate for the development of high-performance electrocatalysts for determination of KPC. Copyright © 2015 Elsevier B.V. All rights reserved.
Highly efficient and compatible shampoo for use after hair transplant.
Schweiger, Dorothea; Schoelermann, Andrea M; Filbry, Alexander; Hamann, Tina; Moser, Claudia; Rippke, Frank
2015-01-01
Sensitive or hyperreactive skin is a common condition defined by prickling, burning, pain, and pruritus. Although this skin problem was initially described on the face, the scalp is often affected. A sensitive scalp can react with irritation to harsh surfactants or other additives which are often present in shampoos. For this reason, we developed a new rinse-off hypertolerant shampoo specifically designed for the hypersensitive and problematic scalp. The shampoo formulation is based on an extremely mild surfactant system and contains bisabolol, an anti-irritant and anti-inflammatory ingredient of chamomile. The shampoo is free of additives such as perfumes, silicones, colorants, parabens, paraffins, and betaine. Since skin can remain in a hyperreactive state after wounding, the status after hair transplantation was chosen as a model system to test the shampoo. Scalp condition and compatibility of each volunteer were analyzed by a plastic surgeon directly after hair transplant and after stitch removal. The plastic surgeons also rated whether they would recommend the further use of the test shampoo. Additionally, volunteers completed a self-assessment questionnaire. Following hair transplantation, regular use of the shampoo resulted in a significant reduction in the extent of scabbing and erythema. This was confirmed by dermatological scalp examinations performed by the plastic surgeon as well as in volunteers' self-assessments. The plastic surgeon highly recommended the further use of the test shampoo after hair transplant to all study participants. Application of the test shampoo demonstrated excellent skin compatibility and product efficacy after hair transplant. The test shampoo significantly reduced the extent of scabs and erythema. Therefore, the shampoo is ideally suited for use after hair transplantation and for the treatment of sensitive scalp. The excellent skin compatibility is because of the mild surfactant system, the calming ingredient bisabolol, and the absence of potentially irritating ingredients.
Yang, Libin; Sang, Qinqin; Du, Juan; Yang, Ming; Li, Xiuling; Shen, Yu; Han, Xiaoxia; Jiang, Xin; Zhao, Bing
2018-06-06
Ag simultaneously deposited and doped TiO2 (Ag-TiO2) hybrid nanoparticles (NPs) were prepared via a sol-hydrothermal method, as both a sensitive surface-enhanced Raman scattering (SERS) substrate and a superior photocatalyst for the first time. Ag-TiO2 hybrid NPs exhibit excellent SERS performance for several probe molecules and the enhancement factor is calculated to be 1.86 × 105. The detection limit of the 4-mercaptobenzoic acid (4-MBA) probe on the Ag-TiO2 substrate is 1 × 10-9 mol L-1, which is four orders of magnitude lower than that on pure TiO2 as a consequence of the synergistic effects of TiO2 and Ag. This is the highest SERS sensitivity among the reported semiconductor substrates and even comparable to noble metal substrates, and a SERS enhancement mechanism from the synergistic contribution of the semiconductor and noble metal was proposed. And importantly, the Ag-TiO2 hybrid shows excellent photocatalytic degradation activity for the detected species under UV light irradiation at lower concentration conditions, even for the hard to degrade 4-MBA molecule. This makes the Ag-TiO2 hybrid promising as a dual-function platform for both highly sensitive SERS detection and photocatalytic degradation of a pollutant system. Moreover, it also proves that the Ag-TiO2 hybrid can serve as a promising recyclable SERS-active substrate by virtue of its photocatalytic self-cleaning properties for some specific applications, for instance comparative studies of different species on the same SERS platform, in addition to the economic benefit.
Diocou, S; Volpe, A; Jauregui-Osoro, M; Boudjemeline, M; Chuamsaamarkkee, K; Man, F; Blower, P J; Ng, T; Mullen, G E D; Fruhwirth, G O
2017-04-19
Cancer cell metastasis is responsible for most cancer deaths. Non-invasive in vivo cancer cell tracking in spontaneously metastasizing tumor models still poses a challenge requiring highest sensitivity and excellent contrast. The goal of this study was to evaluate if the recently introduced PET radiotracer [ 18 F]tetrafluoroborate ([ 18 F]BF 4 - ) is useful for sensitive and specific metastasis detection in an orthotopic xenograft breast cancer model expressing the human sodium iodide symporter (NIS) as a reporter. In vivo imaging was complemented by ex vivo fluorescence microscopy and γ-counting of harvested tissues. Radionuclide imaging with [ 18 F]BF 4 - (PET/CT) was compared to the conventional tracer [ 123 I]iodide (sequential SPECT/CT). We found that [ 18 F]BF 4 - was superior due to better pharmacokinetics, i.e. faster tumor uptake and faster and more complete clearance from circulation. [ 18 F]BF 4 - -PET was also highly specific as in all detected tissues cancer cell presence was confirmed microscopically. Undetected comparable tissues were similarly found to be free of metastasis. Metastasis detection by routine metabolic imaging with [ 18 F]FDG-PET failed due to low standard uptake values and low contrast caused by adjacent metabolically active organs in this model. [ 18 F]BF 4 - -PET combined with NIS expressing disease models is particularly useful whenever preclinical in vivo cell tracking is of interest.
Bhadoria, Ajeet Singh; Kasar, Pradeep Kumar; Toppo, Neelam Anupama
2015-01-01
Globally the increasing prevalence of diabetes mellitus (DM) is major public health concern. The Indian Diabetes Risk Score (IDRS) was developed by Madras Diabetes Research Foundation (MDRF) as a simple tool to help detect undiagnosed type 2 DM (T2DM) in the community. We conducted a study among 911 adults of Jabalpur District to validate the IDRS score against increased fasting blood sugar levels in diagnosing T2DM. T2DM was confirmed either by history of previously known disease or fasting plasma glucose ≥126 mg/dl on two occasions. Sensitivity, specificity, positive predictive value, negative predictive value, Youden index (sensitivity + specificity -1), likelihood ratio for positive test, and likelihood ratio for negative test were calculated for IDRS cut-offs of ≥20, ≥40, ≥60, and ≥80 against the presence of T2DM (either known diabetic or fasting plasma glucose >126 mg/dl on two occasions). The overall prevalence of T2DM was 9.99% (95% confidence interval, 8.04-11.94%). In the Receiver operating characteristic analysis, IDRS had an area under the curve of 0.736 (P < 0.001). The best cut-off was IDRS 40 with a sensitivity, specificity, and Youden index of 60.4%, 70.7%, and 0.31, respectively. The findings of our study indicate that IDRS has excellent predictive value for detecting undiagnosed diabetes in the community and IDRS is also a much stronger risk indicator than examining individual risk factors like age, family history, obesity, or physical activity.
Kumar, Addepalli U.; Jonnadula, Ganesh B.; Garudadri, Chandrasekhar; Rao, Harsha L.; Senthil, Sirisha; Papas, Eric B.; Sankaridurg, Padmaja; Khanna, Rohit C.
2013-01-01
Purpose To compare the diagnostic performance of glaucoma specialists and experienced optometrists in gonioscopy and optic disc assessment. Methods This study was done to validate the diagnostic performance of two experienced optometrists for using their skills of detecting glaucoma using gonioscopy and optic disc assessment in a major epidemiological study, the L V Prasad Eye Institute Glaucoma Epidemiology and Molecular Genetics Study (LVPEI-GLEAMS). Gonioscopic findings for 150 eyes were categorized as 0, 1 and 2 for open angle, primary angle closure suspect (PACS) and primary angle closure (PAC) respectively. Optic disc findings for 200 eyes were categorized as 0, 1 and 2 for normal, suspects and glaucomatous respectively. Weighted kappa (κ) and diagnostic accuracy parameters were calculated. Two optometrists (#1 and #2) participated in the study. Results Agreement between glaucoma specialists and optometrist for interpretation of gonioscopy to discriminate PACS and PAC from open angles and for interpretation of optic disc to discriminate glaucomatous and suspicious discs from normal, the kappa (κ) was 0.92 and 0.84 and 0.90 and 0.89 for optometrists #1 and #2 respectively. Sensitivities and specificities were above 90% for gonioscopy. Optic disc evaluation had specificities greater than 95% to discriminate normal from glaucomatous discs while the sensitivities were 83% and 93% for optometrists #1 and #2 respectively. Conclusion Agreement between optometrists and glaucoma specialists, in diagnostic performance of gonioscopy and optic assessment was excellent with high sensitivity and specificity. Hence, we conclude that the experienced optometrists can detect glaucoma accurately in the LVPEI-GLEAMS.
Böker, Sarah M.; Bender, Yvonne Y.; Diederichs, Gerd; Fallenberg, Eva M.; Wagner, Moritz; Hamm, Bernd; Makowski, Marcus R.
2017-01-01
Objectives To determine the diagnostic performance of susceptibility-weighted magnetic resonance imaging (SWMR) for the detection of pineal gland calcifications (PGC) compared to conventional magnetic resonance imaging (MRI) sequences, using computed tomography (CT) as a reference standard. Methods 384 patients who received a 1.5 Tesla MRI scan including SWMR sequences and a CT scan of the brain between January 2014 and October 2016 were retrospectively evaluated. 346 patients were included in the analysis, of which 214 showed PGC on CT scans. To assess correlation between imaging modalities, the maximum calcification diameter was used. Sensitivity and specificity and intra- and interobserver reliability were calculated for SWMR and conventional MRI sequences. Results SWMR reached a sensitivity of 95% (95% CI: 91%-97%) and a specificity of 96% (95% CI: 91%-99%) for the detection of PGC, whereas conventional MRI achieved a sensitivity of 43% (95% CI: 36%-50%) and a specificity of 96% (95% CI: 91%-99%). Detection rates for calcifications in SWMR and conventional MRI differed significantly (95% versus 43%, p<0.001). Diameter measurements between SWMR and CT showed a close correlation (R2 = 0.85, p<0.001) with a slight but not significant overestimation of size (SWMR: 6.5 mm ± 2.5; CT: 5.9 mm ± 2.4, p = 0.02). Interobserver-agreement for diameter measurements was excellent on SWMR (ICC = 0.984, p < 0.0001). Conclusions Combining SWMR magnitude and phase information enables the accurate detection of PGC and offers a better diagnostic performance than conventional MRI with CT as a reference standard. PMID:28278291
Widdifield, Jessica; Bombardier, Claire; Bernatsky, Sasha; Paterson, J Michael; Green, Diane; Young, Jacqueline; Ivers, Noah; Butt, Debra A; Jaakkimainen, R Liisa; Thorne, J Carter; Tu, Karen
2014-06-23
We have previously validated administrative data algorithms to identify patients with rheumatoid arthritis (RA) using rheumatology clinic records as the reference standard. Here we reassessed the accuracy of the algorithms using primary care records as the reference standard. We performed a retrospective chart abstraction study using a random sample of 7500 adult patients under the care of 83 family physicians contributing to the Electronic Medical Record Administrative data Linked Database (EMRALD) in Ontario, Canada. Using physician-reported diagnoses as the reference standard, we computed and compared the sensitivity, specificity, and predictive values for over 100 administrative data algorithms for RA case ascertainment. We identified 69 patients with RA for a lifetime RA prevalence of 0.9%. All algorithms had excellent specificity (>97%). However, sensitivity varied (75-90%) among physician billing algorithms. Despite the low prevalence of RA, most algorithms had adequate positive predictive value (PPV; 51-83%). The algorithm of "[1 hospitalization RA diagnosis code] or [3 physician RA diagnosis codes with ≥1 by a specialist over 2 years]" had a sensitivity of 78% (95% CI 69-88), specificity of 100% (95% CI 100-100), PPV of 78% (95% CI 69-88) and NPV of 100% (95% CI 100-100). Administrative data algorithms for detecting RA patients achieved a high degree of accuracy amongst the general population. However, results varied slightly from our previous report, which can be attributed to differences in the reference standards with respect to disease prevalence, spectrum of disease, and type of comparator group.
Szunerits, Sabine; Boukherroub, Rabah
2018-06-06
Reliable data obtained from analysis of DNA, proteins, bacteria and other disease-related molecules or organisms in biological samples have become a fundamental and crucial part of human health diagnostics and therapy. The development of non-invasive tests that are rapid, sensitive, specific and simple would allow patient discomfort to be prevented, delays in diagnosis to be avoided and the status of a disease to be followed up. Bioanalysis is thus a progressive discipline for which the future holds many exciting opportunities. The use of biosensors for the early diagnosis of diseases has become widely accepted as a point-of-care diagnosis with appropriate specificity in a short time. To allow a reliable diagnosis of a disease at an early stage, highly sensitive biosensors are required as the corresponding biomarkers are generally expressed at very low concentrations. In the past 50 years, various biosensors have been researched and developed encompassing a wide range of applications. This contrasts the limited number of commercially available biosensors. When it comes to sensing of biomarkers with the required picomolar (pM) sensitivity for real-time sensing of biological samples, only a handful of sensing systems have been proposed, and these are often rather complex and costly. Lately, graphene-based materials have been considered as superior over other nanomaterials for the development of sensitive biosensors. The advantages of graphene-based sensor interfaces are numerous, including enhanced surface loading of the desired ligand due to the high surface-to-volume ratio, excellent conductivity and a small band gap that is beneficial for sensitive electrical and electrochemical read-outs, as well as tunable optical properties for optical read-outs such as fluorescence and plasmonics. In this paper, we review the advances made in recent years on graphene-based biosensors in the field of medical diagnosis.
Stokke, Thomas M; Ruddox, Vidar; Sarvari, Sebastian I; Otterstad, Jan E; Aune, Erlend; Edvardsen, Thor
2014-11-01
Physical examination and auscultation can be challenging for medical students. The aim of this study was to investigate whether a brief session of group training in focused cardiac ultrasound (FCU) with a pocket-sized device would allow medical students to improve their ability to detect clinically relevant cardiac lesions at the bedside. Twenty-one medical students in their clinical curriculum completed 4 hours of FCU training in groups. The students examined patients referred for echocardiography with emphasis on auscultation, followed by FCU. Findings from physical examination and FCU were compared with those from standard echocardiography performed and analyzed by cardiologists. In total, 72 patients were included in the study, and 110 examinations were performed. With a stethoscope, sensitivity to detect clinically relevant (moderate or greater) valvular disease was 29% for mitral regurgitation, 33% for aortic regurgitation, and 67% for aortic stenosis. FCU improved sensitivity to detect mitral regurgitation (69%, P < .001). However, sensitivity to detect aortic regurgitation (43%) and aortic stenosis (70%) did not improve significantly. Specificity was ≥89% for all valvular diagnoses by both methods. For nonvalvular diagnoses, FCU's sensitivity to detect moderate or greater left ventricular dysfunction (90%) was excellent, detection of right ventricular dysfunction (79%) was good, while detection of dilated left atrium (53%), dilated right atrium (49%), pericardial effusion (40%), and dilated aortic root (25%) was less accurate. Specificity varied from 57% to 94%. After brief group training in FCU, medical students could detect mitral regurgitation significantly better compared with physical examination, whereas detection of aortic regurgitation and aortic stenosis did not improve. Left ventricular dysfunction was detected with high sensitivity. More extensive training is advised. Copyright © 2014 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.
McCaul, Courtney; Boone, Kyle B; Ermshar, Annette; Cottingham, Maria; Victor, Tara L; Ziegler, Elizabeth; Zeller, Michelle A; Wright, Matthew
2018-01-18
To cross-validate the Dot Counting Test in a large neuropsychological sample. Dot Counting Test scores were compared in credible (n = 142) and non-credible (n = 335) neuropsychology referrals. Non-credible patients scored significantly higher than credible patients on all Dot Counting Test scores. While the original E-score cut-off of ≥17 achieved excellent specificity (96.5%), it was associated with mediocre sensitivity (52.8%). However, the cut-off could be substantially lowered to ≥13.80, while still maintaining adequate specificity (≥90%), and raising sensitivity to 70.0%. Examination of non-credible subgroups revealed that Dot Counting Test sensitivity in feigned mild traumatic brain injury (mTBI) was 55.8%, whereas sensitivity was 90.6% in patients with non-credible cognitive dysfunction in the context of claimed psychosis, and 81.0% in patients with non-credible cognitive performance in depression or severe TBI. Thus, the Dot Counting Test may have a particular role in detection of non-credible cognitive symptoms in claimed psychiatric disorders. Alternative to use of the E-score, failure on ≥1 cut-offs applied to individual Dot Counting Test scores (≥6.0″ for mean grouped dot counting time, ≥10.0″ for mean ungrouped dot counting time, and ≥4 errors), occurred in 11.3% of the credible sample, while nearly two-thirds (63.6%) of the non-credible sample failed one of more of these cut-offs. An E-score cut-off of 13.80, or failure on ≥1 individual score cut-offs, resulted in few false positive identifications in credible patients, and achieved high sensitivity (64.0-70.0%), and therefore appear appropriate for use in identifying neurocognitive performance invalidity.
Prevention of bacterial foodborne disease using nanobiotechnology.
Billington, Craig; Hudson, J Andrew; D'Sa, Elaine
2014-01-01
Foodborne disease is an important source of expense, morbidity, and mortality for society. Detection and control constitute significant components of the overall management of foodborne bacterial pathogens, and this review focuses on the use of nanosized biological entities and molecules to achieve these goals. There is an emphasis on the use of organisms called bacteriophages (phages: viruses that infect bacteria), which are increasingly being used in pathogen detection and biocontrol applications. Detection of pathogens in foods by conventional techniques is time-consuming and expensive, although it can also be sensitive and accurate. Nanobiotechnology is being used to decrease detection times and cost through the development of biosensors, exploiting specific cell-recognition properties of antibodies and phage proteins. Although sensitivity per test can be excellent (eg, the detection of one cell), the very small volumes tested mean that sensitivity per sample is less compelling. An ideal detection method needs to be inexpensive, sensitive, and accurate, but no approach yet achieves all three. For nanobiotechnology to displace existing methods (culture-based, antibody-based rapid methods, or those that detect amplified nucleic acid) it will need to focus on improving sensitivity. Although manufactured nonbiological nanoparticles have been used to kill bacterial cells, nanosized organisms called phages are increasingly finding favor in food safety applications. Phages are amenable to protein and nucleic acid labeling, and can be very specific, and the typical large "burst size" resulting from phage amplification can be harnessed to produce a rapid increase in signal to facilitate detection. There are now several commercially available phages for pathogen control, and many reports in the literature demonstrate efficacy against a number of foodborne pathogens on diverse foods. As a method for control of pathogens, nanobiotechnology is therefore flourishing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferreira, C; Ahmad, S; Firestone, B
Purpose: To compare dosimetrically three plan calculation systems (Plato, Varian Brachytherapy, and in-house-made Excel) available for I-125 COMS eye plaque treatment with measurement. Methods: All systems assume homogeneous media and calculations are based on a three-dimensional Cartesian coordinates, Plato and Brachytherapy Planning are based on AAPM TG-43 and the in-house Excel program only on inverse square corrections. Doses at specific depths were measured with EBT3 Gafchromic film from a fully loaded and a partially loaded 16 mm plaque (13 and 8 seeds respectively, I-125, model 6711 GE, Oncura). Measurements took place in a water tank, utilizing solid water blocks andmore » a 3D-printed plaque holder. Taking advantage that gafchromic film has low energy dependence, a dose step wedge was delivered with 6 MV photon beam from a Varian 2100 EX linac for calibration. The gray-scale to dose in cGy was obtained with an Epson Expression 10000 XL scanner in the green channel. Treatment plans were generated for doses of 2200 cGy to a depth of 7 mm, and measurements were taken on a sagittal plane. Results: The calculated dose at the prescription point was 2242, 2344, and 2211 cGy with Excel, Brachyvision and Plato respectively for a fully loaded plaque, for the partially loaded plaque the doses were 2266, 2477, and 2193 cGy respectively. At 5 mm depth the doses for Brachyvision and Plato were comparable (3399 and 3267 cGy respectively), however, the measured dose in film was 3180 cGy which was lower by as much as 6.4% in the fully loaded plaque and 7.6% in the partially loaded plaque. Conclusion: Careful methodology and calibration are essential when measuring doses at specific depth due to the sensitivity and rapid dose fall off of I-125.« less
Fluorescence spectroscopy for throat cancer detection using human saliva
NASA Astrophysics Data System (ADS)
Kumar, Pavan; Singh, Ashutosh; Zaffar, Mohammad; Pradhan, Asima
2018-02-01
Throat precancer detection using fluorescence from human saliva is reported here. It may be noted that accessing the throat for investigation is cumbersome and use of saliva as a diagnostic medium may ease the process. The study has been conducted on three groups of patients: oral squamous cell carcinoma (OSCC), dysplasia, and normal (control). An in-house developed compact set-up has been used for fluorescence measurements. The compact system consist of a 375 nm laser diode, collimating lens, long pass filter, fibers, and cuvette holder. Major and minor bands of flavin adenine dinucleotide (FAD) and porphyrin are observed in the spectra. A receiver operating characteristic (ROC) analysis has been used to evaluate the diagnostic performance. Area under the spectra has been chosen for discrimination among the groups and is able to differentiate OSCC to normal, dysplasia to normal, and OSCC to dysplasia with sensitivities 100% (48/48), 92% (32/35), 77% (37/48), and specificities 96% (50/52), 96% (50/52), 89% (31/35) with the accuracy of 98%, 94% and 82% respectively. Sensitivity and specificity, when differentiating OSCC to normal and dysplasia to normal, are significantly large, which indicates that human saliva may be an excellent diagnostic medium for early detection of throat cancer.
Brightness discrimination test is not useful in screening for open angle glaucoma.
Peter, E; Thomas, R; Muliyil, J
1996-06-01
Brightness discrimination test (BDT) is routinely employed to assess asymmetrical optic nerve dysfunction and has been suggested as a screening test for primary open angle glaucoma (POAG). We tested the reliability and validity of BDT in the diagnosis of POAG. The study groups included 34 patients with established primary open angle glaucoma, 20 glaucoma suspects, and 33 age-sex matched controls. Cataract was not an exclusion criterion in these groups. The normal brightness score was determined to be 88% (mean score, 94%-2 SD) in a pilot study. Brightness discrimination test was performed in all subjects by two observers independently. BDT showed an excellent interobserver agreement (weighted Kappa 0.84). The presence of a cataract alone increased the risk of brightness impairment twofold, glaucoma alone increased the risk eightfold, and the presence of both conditions by 17 times compared to those with neither condition. BDT was not a useful test in the diagnosis of POAG (sensitivity 67% and specificity 93%); the ability to detect a significant field defect was also poor (sensitivity 53% and specificity 76%). There was poor association between decreased brightness scores and asymmetrical field defects as determined by the Humphrey's field analyzer (HFA).
Ramsey, David J; Sunness, Janet S; Malviya, Poorva; Applegate, Carol; Hager, Gregory D; Handa, James T
2014-07-01
To develop a computer-based image segmentation method for standardizing the quantification of geographic atrophy (GA). The authors present an automated image segmentation method based on the fuzzy c-means clustering algorithm for the detection of GA lesions. The method is evaluated by comparing computerized segmentation against outlines of GA drawn by an expert grader for a longitudinal series of fundus autofluorescence images with paired 30° color fundus photographs for 10 patients. The automated segmentation method showed excellent agreement with an expert grader for fundus autofluorescence images, achieving a performance level of 94 ± 5% sensitivity and 98 ± 2% specificity on a per-pixel basis for the detection of GA area, but performed less well on color fundus photographs with a sensitivity of 47 ± 26% and specificity of 98 ± 2%. The segmentation algorithm identified 75 ± 16% of the GA border correctly in fundus autofluorescence images compared with just 42 ± 25% for color fundus photographs. The results of this study demonstrate a promising computerized segmentation method that may enhance the reproducibility of GA measurement and provide an objective strategy to assist an expert in the grading of images.
Su, Min; Ge, Lei; Kong, Qingkun; Zheng, Xiaoxiao; Ge, Shenguang; Li, Nianqiang; Yu, Jinghua; Yan, Mei
2015-01-15
A novel electrochemical lab-on-paper cyto-device (ELPCD) was fabricated to demonstrate sensitive and specific cancer cell detection as well as in-situ monitoring of multi-glycans on living cancer cells. In this ELPCD, aptamers modified three-dimensional macroporous Au-paper electrode (Au-PE) was employed as the working electrode for specific and efficient cancer cell capture. Using a sandwich format, sensitive and reproducible cell detection was achieved in this ELPCD on the basis of the electrochemical signal amplification of the Au-PE and the horseradish peroxidase-lectin electrochemical probe. The ELPCD displayed excellent analytical performance for the detection of four K562 cells with a wide linear calibration range from 550 to 2.0×10(7) cells mL(-1). Then, this ELPCD was successfully applied to determine cell-surface multi-glycans in parallel and in-situ monitor multi-glycans expression on living cells in response to drug treatment through in-electrode 3D cell culture. The proposed method provides promising application in decipherment of the glycomic codes as well as clinical diagnosis and treatment in early process of cancer. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Gareau, Daniel S.; Karen, Julie K.; Dusza, Stephen W.; Tudisco, Marie; Nehal, Kishwer S.; Rajadhyaksha, Milind
2009-05-01
Recent studies have demonstrated the ability of confocal fluorescence mosaicing microscopy to rapidly detect basal cell carcinomas (BCCs) directly in thick and fresh Mohs surgical excisions. Mosaics of confocal images display large areas of tissue with high resolution and magnification equivalent to 2×, which is the standard magnification when examining pathology. Comparison of mosaics to Mohs frozen histopathology was shown to be excellent for all types of BCCs. However, comparisons in the previous studies were visual and qualitative. In this work, we report the results of a semiquantitative preclinical study in which 45 confocal mosaics are blindly evaluated for the presence (or absence) of BCC tumor. The evaluations are made by two clinicians: a senior Mohs surgeon with prior expertise in interpreting confocal images, and a novice Mohs fellow with limited experience. The blinded evaluation is compared to the gold standard of frozen histopathology. BCCs are detected with an overall sensitivity of 96.6%, specificity of 89.2%, positive predictive value of 93.0%, and negative predictive value of 94.7%. The results demonstrate the potential clinical utility of confocal mosaicing microscopy toward rapid surgical pathology at the bedside to expedite and guide surgery.
64-slice MDCT angiography of upper extremity in assessment of native hemodialysis access.
Wasinrat, Jitladda; Siriapisith, Thanongchai; Thamtorawat, Somrach; Tongdee, Trongtum
2011-01-01
To compare multidetector row computed tomographic (MDCT) angiography with conventional digital subtraction angiography (DSA) in the evaluation of vascular access stenoses in hemodialysis patients. Twenty-one consecutive patients were imaged with MDCT angiography and subsequent DSA. The superficial vein of leg was used as the route for intravenous administration. The vascular stenosis was assessed in not significant (<50% stenosis), moderate stenosis (50%-74% stenosis), severe stenosis (75%-99%), and total occlusion (100%). The accuracy, sensitivity, specificity, positive, and negative predictive values were calculated for significant vascular stenosis using DSA as the standard reference. The sensitivity and specificity of MDCT angiography for the detection of significant hemodialysis vascular access were 100% (95% CI, 89.3%-100%) and 94.8% (95% CI, 89.1%-97.6%), respectively. The positive and negative predictive values were 84.2% (95% CI, 68.1%-93.4%) and 100% (95% CI, 95.8%-100%), respectively. The accuracy of MDCT angiography for detection of significant stenoses was 95.9% (95% CI, 91.4%-97.0%). MDCT angiography provides excellent correlation in vascular stenosis as compared with DSA in hemodialysis access. Complete assessment of entire vascular segments could be performing with MDCT angiography in planning before endovascular intervention or surgical correction.
Ratiometric near infrared luminescent thermometer based on lanthanide metal-organic frameworks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yue, Dan; Zhang, Jun; Zhao, Dian
2016-09-15
A near infrared luminescent MOFs thermometer (Nd{sub 0.676}Yb{sub 0.324}BTC) was prepared via a simple solvothermal method using Ln{sup 3+} (Ln=Nd, Yb) ions and 1, 3, 5-benznenetricarboxylic acid (H{sub 3}BTC), and characterized by PXRD, TGA, ICP, and photoluminescence (PL) spectrum. These results indicate that the Nd{sub 0.676}Yb{sub 0.324}BTC displays high relative sensitivity and excellent repeatability in the physiological temperature range (288–323 K), and the maximum relative sensitivity is determined to be 1.187% K{sup −1} at 323 K. These NIR luminescent MOFs may have potential applications in physiological temperature sensing. - Graphical abstract: A near infrared luminescent MOFs thermometer (Nd{sub 0.054}Yb{sub 0.946}BTCmore » ) displays high relative sensitivity and excellent repeatability in the physiological temperature range (288–323 K). Display Omitted - Highlights: • A ratiometric near infrared luminescent MOFs thermometer (Nd{sub 0.676}Yb{sub 0.324}BTC) was prepared via a simple solvothermal method. • The maximum relative sensitivity of Nd{sub 0.676}Yb{sub 0.324}BTC is determined to be 1.187% K{sup −1} at 323 K. • Nd{sub 0.676}Yb{sub 0.324}BTC showed excellent repeatability in the physiological temperature range (288–323 K).« less
Colorimetric and fluorescent detection of hydrazine with high sensitivity and excellent selectivity
NASA Astrophysics Data System (ADS)
Shi, Bingjie; Qi, Sujie; Yu, Mingming; Liu, Chunxia; Li, Zhanxian; Wei, Liuhe; Ni, Zhonghai
2018-01-01
It is critical to develop probes for rapid, selective, and sensitive detection of the highly toxic hydrazine in both environmental and biological science. In this work, under mild condition, a novel colorimetric and off-on fluorescent probe was synthesized for rapid recognition of hydrazine with excellent selectivity over other various species including some biological species, metal ions and anions. The limit of quantification (LOQ) value was 1.5 × 10- 4 M-3.2 × 10- 3 M (colorimetric method) and 1.5 × 10- 4 M - 3.2 × 10- 3 M (fluorescent method) with as low as detection limit of 46.2 μM.
Heidt, Sebastiaan; Haasnoot, Geert W; Claas, Frans H J
2018-05-24
Highly sensitized patients awaiting a renal transplant have a low chance of receiving an organ offer. Defining acceptable antigens and using this information for allocation purposes can vastly enhance transplantation of this subgroup of patients, which is the essence of the Eurotransplant Acceptable Mismatch program. Acceptable antigens can be determined by extensive laboratory testing, as well as on basis of human leukocyte antigen (HLA) epitope analyses. Within the Acceptable Mismatch program, there is no effect of HLA mismatches on long-term graft survival. Furthermore, patients transplanted through the Acceptable Mismatch program have similar long-term graft survival to nonsensitized patients transplanted through regular allocation. Although HLA epitope analysis is already being used for defining acceptable HLA antigens for highly sensitized patients in the Acceptable Mismatch program, increasing knowledge on HLA antibody - epitope interactions will pave the way toward the definition of acceptable epitopes for highly sensitized patients in the future. Allocation based on acceptable antigens can facilitate transplantation of highly sensitized patients with excellent long-term graft survival.
Label-free and pH-sensitive colorimetric materials for the sensing of urea
NASA Astrophysics Data System (ADS)
Li, Lu; Long, Yue; Gao, Jin-Ming; Song, Kai; Yang, Guoqiang
2016-02-01
This communication demonstrates a facile method for naked-eye detection of urea based on the structure color change of pH-sensitive photonic crystals. The insertion of urease provides excellent selectivity over other molecules. The detection of urea in different concentration ranges could be realized by changing the molar ratio between the functional monomer and cross-linker.This communication demonstrates a facile method for naked-eye detection of urea based on the structure color change of pH-sensitive photonic crystals. The insertion of urease provides excellent selectivity over other molecules. The detection of urea in different concentration ranges could be realized by changing the molar ratio between the functional monomer and cross-linker. Electronic supplementary information (ESI) available: Materials and chemicals, characterization, experimental details, and SEM images. See DOI: 10.1039/c5nr07690k
Evaluation of the Abbott ARCHITECT Toxo IgM assay.
Sickinger, Eva; Braun, Hans-Bertram; Praast, Gerald; Stieler, Myriam; Gundlach, Cordelia; Birkenbach, Claudia; Prostko, John; Palafox, Mary Ann; Frias, Edwin; Hsu, Stephen; Matias, Matthew; Pucci, Dominick; Hausmann, Michael; Sagel, Ulrich; Smith, Darwin
2009-07-01
Development of the ARCHITECT Toxo IgM assay has been done to assist the clinician in acute Toxoplasma gondii infection detection, especially in pregnant women. Its use, in conjunction with ARCHITECT Toxo IgG and Toxo Avidity assays, will provide an array of assays particularly useful in the monitoring of pregnant females to determine the risk of maternal transmission of the parasite. Specificity results from 2 testing sites, using populations of pregnant females, hospital patients, and blood donors, demonstrated that the assay has an overall resolved relative specificity of 99.89% (confidence interval, 99.68-99.98%). Relative specificity for pregnant female specimens was 99.95% (n = 2031). Excellent seroconversion sensitivity was observed for the ARCHITECT Toxo IgM assay, which was similar to the Abbott AxSYM Toxo IgM assay (Abbott Laboratories, Abbott Park, IL). In more than 90% of the panels tested, the 1st bleed detected in the serial bleeds was the same for both assays.
Kim, Myoung-Hee; Cho, Young-Shin; Uhm, Wan-Sik; Kim, Sehyun; Bae, Sang-Cheol
2005-06-01
This study aimed to determine the cross-cultural adaptation and validation of the Korean version of the EQ-5D in rheumatic conditions. Translation, back-translation and cognitive debriefing were performed according to the EuroQol group's guidelines. For validity, 508 patients were recruited and administered the EQ-5D, Short-Form 36 and condition-specific measures. Construct validity and sensitivity were evaluated by testing a-priori hypotheses. For reliability, another 57 patients repeated the EQ-5D at 1-week interval, and intra-class correlations (ICC) and kappa statistics were estimated. For responsiveness, another 60 patients repeated it at 12-week interval within the context of clinical trial, and standardized response mean(SRM) were calculated. The cross-cultural adaptation produced no major modifications in the scale. The associations of the EQ-5D with the generic- and condition-specific measures were observed as expected in hypotheses: the higher EQ-5Dindex and EQ-5D(VAS) scores, the better health status by generic- or condition-specific measures, and the better functional class. The ICCs were 0.751 and 0.767, respectively, and kappa ranged from 0.455 to 0.772. The SRM were 0.649 and 0.410, respectively. The Korean EQ-5D exhibits good validity and sensitivity in various rheumatic conditions. Although its reliability and responsiveness were not excellent, it seems acceptable if condition-specific measures are applied together.
Hierarchical nanostructured conducting polymer hydrogel with high electrochemical activity
Pan, Lijia; Yu, Guihua; Zhai, Dongyuan; Lee, Hye Ryoung; Zhao, Wenting; Liu, Nian; Wang, Huiliang; Tee, Benjamin C.-K.; Shi, Yi; Cui, Yi; Bao, Zhenan
2012-01-01
Conducting polymer hydrogels represent a unique class of materials that synergizes the advantageous features of hydrogels and organic conductors and have been used in many applications such as bioelectronics and energy storage devices. They are often synthesized by polymerizing conductive polymer monomer within a nonconducting hydrogel matrix, resulting in deterioration of their electrical properties. Here, we report a scalable and versatile synthesis of multifunctional polyaniline (PAni) hydrogel with excellent electronic conductivity and electrochemical properties. With high surface area and three-dimensional porous nanostructures, the PAni hydrogels demonstrated potential as high-performance supercapacitor electrodes with high specific capacitance (∼480 F·g-1), unprecedented rate capability, and cycling stability (∼83% capacitance retention after 10,000 cycles). The PAni hydrogels can also function as the active component of glucose oxidase sensors with fast response time (∼0.3 s) and superior sensitivity (∼16.7 μA·mM-1). The scalable synthesis and excellent electrode performance of the PAni hydrogel make it an attractive candidate for bioelectronics and future-generation energy storage electrodes. PMID:22645374
Zhou, Jie; Meng, Lingchang; Ye, Weiran; Wang, Qiaolei; Geng, Shizhen; Sun, Chong
2018-08-31
Alzheimer's disease (AD) considered as the third health "killer" has seriously threatened the health of the elderly. However, the modern diagnostic strategies of AD present several disadvantages: the low accuracy and specificity resulting in some false-negative diagnoses, and the poor sensitivity leading to a delayed treatment. In view of this situation, a enzyme-free and target-triggered signal amplification strategy, based on graphene oxide (GO) and entropy-driven strand displacement reaction (ESDR) principle, was proposed. In this strategy, when the hairpin structure probes (H)specially binds with beta-amyloid-(1-42) oligomers (Aβ42 oligomers), it's structure will be opened, causing the bases complementary to FAM-labeled replacement probes R (R1 and R2) exposed. At this time, R1 and R2 will hybridize with H, resulting in the bound Aβ42 oligomers released. The released Aβ42 oligomers would participate in the next cycle reaction, making the signal amplified. As a quencher, GO could absorb the free single-stranded DNA R1 and R2 and quench their fluorescence; however, the DNA duplex still exists free and keeps its signal-on. Through the detection of Aβ42 oligomers in exosomes, this ultrasensitive detection method with the advantages of low limit of detection (LOD, 20 pM), great accuracy, excellent precision and convenience provides an excellent prospect for AD's early diagnosis. Copyright © 2018 Elsevier B.V. All rights reserved.
Is appendiceal CT scan overused for evaluating patients with right lower quadrant pain?
Safran, D B; Pilati, D; Folz, E; Oller, D
2001-05-01
Reports citing excellent sensitivity, specificity, and predictive accuracy of focused appendiceal computed tomography (CT) and showing an overall reduction in resource use and nontherapeutic laparotomies have led to increasing use of that imaging modality. Diagnostic algorithms have begun to incorporate appendiceal CT for patients presenting to the emergency department with right lower quadrant pain. We present a series of 4 cases in which use of appendiceal CT ultimately led to increased cost, resource use, and complexity in patient care. The results of these cases support an argument against unbridled use of appendiceal CT scanning and reinforce the need for clinical evaluation by the operating surgeon before routine performance of appendiceal CT scan.
Validation of an asthma questionnaire for use in healthcare workers
Delclos, G L; Arif, A A; Aday, L; Carson, A; Lai, D; Lusk, C; Stock, T; Symanski, E; Whitehead, L W; Benavides, F G; Antó, J M
2006-01-01
Background Previous studies have described increased occurrence of asthma among healthcare workers, but to our knowledge there are no validated survey questionnaires with which to study this occupational group. Aims To develop, validate, and refine a new survey instrument on asthma for use in epidemiological studies of healthcare workers. Methods An initial draft questionnaire, designed by a multidisciplinary team, used previously validated questions where possible; the occupational exposure section was developed by updating health services specific chemical lists through hospital walk‐through surveys and review of material safety data sheets. A cross‐sectional validation study was conducted in 118 non‐smoking subjects, who also underwent bronchial challenge testing, an interview with an industrial hygienist, and measurement of specific IgE antibodies to common aeroallergens. Results The final version consisted of 43 main questions in four sections. Time to completion of the questionnaire ranged from 13 to 25 minutes. Test–retest reliability of asthma and allergy items ranged from 75% to 94%, and internal consistency for these items was excellent (Cronbach's α ⩾ 0.86). Against methacholine challenge, an eight item combination of asthma related symptoms had a sensitivity of 71% and specificity of 70%; against a physician diagnosis of asthma, this same combination showed a sensitivity of 79% and specificity of 98%. Agreement between self‐reported exposures and industrial hygienist review was similar to previous studies and only moderate, indicating the need to incorporate more reliable methods of exposure assessment. Against the aerollergen panel, the best combinations of sensitivity and specificity were obtained for a history of allergies to dust, dust mite, and animals. Conclusions Initial evaluation of this new questionnaire indicates good validity and reliability, and further field testing and cross‐validation in a larger healthcare worker population is in progress. The need for development of more reliable occupational exposure assessment methods that go beyond self‐report is underscored. PMID:16497858
Waszkiewicz, Napoleon; Zalewska-Szajda, Beata; Chojnowska, Sylwia; Szajda, Sławomir Dariusz; Zalewska, Anna; Konarzewska, Beata; Szulc, Agata; Wojtulewska-Supron, Aleksandra; Kępka, Alina; Knaś, Małgorzata; Ładny, Jerzy Robert; Milewski, Robert; Zwierz, Krzysztof
2013-01-01
Severe periodontitis leading to tooth loss is found in 5-15% of most populations worldwide. The applicability of salivary β -hexosaminidase (β-HEX A%, percentage of β-HEX A isoenzyme to total β-HEX) and β-HEX B% (β-HEX B/β-HEX) indexes was investigated as a possible marker of periodontitis. Thirty three alcohol-dependent smokers (AS) and 32 healthy controls (C) were enrolled in the study. The activity of β-HEX was measured spectrophotometrically. β-HEX A% was significantly higher and β-HEX B% was lower in AS than in C group. We found a significant correlation between β-HEX A% and gingival index (GI) and an inverse correlation between β-HEX A% and salivary flow (SF), in all groups. Salivary β-HEX A% index in smoking alcoholics at 0.23 had excellent sensitivity (96%) and specificity (91%); the AUC for β-HEX A% was high (0.937). There were no correlations between amount/duration-time of alcohol drinking/smoking and β-HEX A% or β-HEX B%. We found significant correlations between the time period of denture wearing and GI, papilla bleeding index (PBI), and decayed missing filled teeth index (DMFT) and between GI and the amount of smoked cigarettes per day. Bad periodontal state was most likely due to the nicotine dependence. Salivary β-HEX A% is a promising excellent marker for the diagnosis of periodontitis.
Developmental effects of the protein kinase inhibitor kenpaullone on the sea urchin embryo.
Anello, Letizia; Cavalieri, Vincenzo; Di Bernardo, Maria
2018-01-01
The selection and validation of bioactive compounds require multiple approaches, including in-depth analyses of their biological activity in a whole-animal context. We exploited the sea urchin embryo in a rapid, medium-scale range screening to test the effects of the small synthetic kinase inhibitor kenpaullone. We show that sea urchin embryos specifically respond to this molecule depending on both dose and timing of administration. Phenotypic effects of kenpaullone are not immediately visible, since this molecule affects neither the fertilization nor the spatial arrangement of blastomeres at early developmental stages. Nevertheless, kenpaullone exposure from the beginning of embryogenesis profoundly perturbs specification, detachment from the epithelium, and migration of the primary mesenchyme cells, thus affecting the whole embryonic epithelial mesenchymal transition process. Our results reaffirm the sea urchin embryo as an excellent and sensitive in vivo system, which provides straightforward and rapid response to external stimuli. Copyright © 2017 Elsevier Inc. All rights reserved.
Detecting the Presence of a Personality Disorder Using Interpersonal and Self-Dysfunction.
Beeney, Joseph E; Lazarus, Sophie A; Hallquist, Michael N; Stepp, Stephanie D; Wright, Aidan G C; Scott, Lori N; Giertych, Rachel A; Pilkonis, Paul A
2018-03-05
Calls have increased to place interpersonal and self-disturbance as defining features of personality disorders (PDs). Findings from a methodologically diverse set of studies suggest that a common factor undergirds all PDs. The nature of this core of PDs, however, is not clear. In the current study, interviews were completed for DSM-IV PD diagnosis and interpersonal dysfunction independently with 272 individuals (PD = 191, no-PD = 91). Specifically, we evaluated interpersonal dysfunction across social domains. In addition, we empirically assessed the structure of self-dysfunction in PDs. We found dysfunction in work and romantic domains, and unstable identity uniquely predicted variance in the presence of a PD. Using receiver operating characteristic analysis, we found that the interpersonal dysfunction and self-dysfunction scales each predicted PDs with high accuracy. In combination, the scales resulted in excellent sensitivity (.90) and specificity (.88). The results support interpersonal and self-dysfunction as general factors of PD.
Analyte-Triggered DNA-Probe Release from a Triplex Molecular Beacon for Nanopore Sensing.
Guo, Bingyuan; Sheng, Yingying; Zhou, Ke; Liu, Quansheng; Liu, Lei; Wu, Hai-Chen
2018-03-26
A new nanopore sensing strategy based on triplex molecular beacon was developed for the detection of specific DNA or multivalent proteins. The sensor is composed of a triplex-forming molecular beacon and a stem-forming DNA component that is modified with a host-guest complex. Upon target DNA hybridizing with the molecular beacon loop or multivalent proteins binding to the recognition elements on the stem, the DNA probe is released and produces highly characteristic current signals when translocated through α-hemolysin. The frequency of current signatures can be used to quantify the concentrations of the target molecules. This sensing approach provides a simple, quick, and modular tool for the detection of specific macromolecules with high sensitivity and excellent selectivity. It may find useful applications in point-of-care diagnostics with a portable nanopore kit in the future. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kulkarni, Harshad R; Singh, Aviral; Schuchardt, Christiane; Niepsch, Karin; Sayeg, Manal; Leshch, Yevgeniy; Wester, Hans-Juergen; Baum, Richard P
2016-10-01
A potential milestone in personalized nuclear medicine is theranostics of metastatic castration-resistant prostate cancer (mCRPC) based on molecular imaging using PET/CT with 68 Ga-labeled prostate-specific membrane antigen (PSMA) ligands and molecular radiotherapy using PSMA-targeted radioligand therapy (PRLT) with 177 Lu-PSMA ligands. 68 Ga-PSMA PET/CT enables accurate detection of mCRPC lesions with high diagnostic sensitivity and specificity and provides quantitative and reproducible data that can be used to select patients for PRLT and therapeutic monitoring. Our comprehensive experience over the last 3 years using different radioligands indicates that PRLT is highly effective for the treatment of mCRPC, even in advanced cases, and potentially lends a significant benefit to overall and progression-free survival. Additionally, significant improvement in clinical symptoms and excellent palliation of pain can be achieved. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Daphnia have been among the most commonly used test organisms for aquatic toxicity studies due to their sensitivity to contaminants. This sensitivity makes them excellent candidates for development as sentinels to monitor the occurrence of chemicals in the environment. The sequen...
Understanding Canadian Family Policy: Intents and Models.
ERIC Educational Resources Information Center
Kieren, Dianne K.
1991-01-01
Introduces some of the key concepts and issues that face Canadian policymakers as they attempt to provide relevant and sensitive actions in support of families and individuals in families. Reviews the Quebec model, considered to be excellent for the development of humanly sensitive family policy. (Author/JOW)
The Mechanisms and Biomedical Applications of an NIR BODIPY-Based Switchable Fluorescent Probe
Cheng, Bingbing; Bandi, Venugopal; Yu, Shuai; D’Souza, Francis; Nguyen, Kytai T.; Hong, Yi; Tang, Liping; Yuan, Baohong
2017-01-01
Highly environment-sensitive fluorophores have been desired for many biomedical applications. Because of the noninvasive operation, high sensitivity, and high specificity to the microenvironment change, they can be used as excellent probes for fluorescence sensing/imaging, cell tracking/imaging, molecular imaging for cancer, and so on (i.e., polarity, viscosity, temperature, or pH measurement). In this work, investigations of the switching mechanism of a recently reported near-infrared environment-sensitive fluorophore, ADP(CA)2, were conducted. Besides, multiple potential biomedical applications of this switchable fluorescent probe have been demonstrated, including wash-free live-cell fluorescence imaging, in vivo tissue fluorescence imaging, temperature sensing, and ultrasound-switchable fluorescence (USF) imaging. The fluorescence of the ADP(CA)2 is extremely sensitive to the microenvironment, especially polarity and viscosity. Our investigations showed that the fluorescence of ADP(CA)2 can be switched on by low polarity, high viscosity, or the presence of protein and surfactants. In wash-free live-cell imaging, the fluorescence of ADP(CA)2 inside cells was found much brighter than the dye-containing medium and was retained for at least two days. In all of the fluorescence imaging applications conducted in this study, high target-to-noise (>5-fold) was achieved. In addition, a high temperature sensitivity (73-fold per Celsius degree) of ADP(CA)2-based temperature probes was found in temperature sensing. PMID:28208666
The relations of motivational traits with workplace deviance.
Diefendorff, James M; Mehta, Kajal
2007-07-01
The authors developed and tested new theoretical relations between approach and avoidance motivational traits and deviant work behaviors. Approach motivation was divided into 3 traits: personal mastery (i.e., desire to achieve), competitive excellence (i.e., desire to perform better than others), and behavioral activation system (BAS) sensitivity (i.e., responsiveness to rewards). Avoidance motivation, which reflects one's sensitivity to negative stimuli and the desire to escape such stimuli, was conceptualized as a unitary construct. Using structural equation modeling, the authors examined the relations of these 4 motivational traits with interpersonal and organizational deviance in a sample of primarily part-time employees. For the approach motivation traits, results showed that personal mastery was negatively related to interpersonal and organizational deviance, BAS sensitivity was positively related to interpersonal and organizational deviance, and competitive excellence was unrelated to both types of workplace deviance. Finally, avoidance motivation was positively related to organizational deviance and interacted with organizational constraints to predict interpersonal deviance.
Design and fabrication of highly sensitive and stable biochip for glucose biosensing
NASA Astrophysics Data System (ADS)
Lu, Shi-Yu; Lu, Yao; Jin, Meng; Bao, Shu-Juan; Li, Wan-Yun; Yu, Ling
2017-11-01
Common producing steps for test strips is complex and fussy. In this work, we proposed a feasible binder-free test strips fabrication method to directly grow enzyme/manganese phosphate nanosheets hybrids on the screen-print electrodes (SPE). Combined with microfluidic packaging technology, the ready-made portable electrochemical biochip shows a wider linear range (1-40 mM, R2 = 0.9998) and excellent stability (maintained 98% response current after 20 days store and retained 75% response current after continuous 30 days determination) for the detection of glucose. Compared with commercial test strips, the biochip exhibits excellent sensitivity, stability and accuracy, which is indicative of its potential application in real samples.
[Significance of PSMA imaging in prostate cancer].
Gasch, C; Düwel, C; Kopka, K; Kratochwil, C; Vinsensia, M; Eiber, M; Maurer, T; Haberkorn, U; Hadaschik, B; Giesel, F L
2017-01-01
Prostate cancer (PCa) is one of the most common malignancies of men in developed countries. To improve clinical diagnostics of PCa, 68 Ga-PSMA-11 was recently introduced as a new PET tracer. 68 Ga-PSMA-11 is able to specifically bind to the prostate-specific membrane antigen (PSMA), which is upregulated on the surface of prostate cancer cells in most patients. To analyse the current significance of 68 Ga-PSMA-11 PET imaging in prostate cancer in relation to staging of men with initial diagnosis, biochemical recurrence and metastatic disease. Retrospective analysis of current literature (PubMed search) regarding 68 Ga-PSMA-11 PET diagnostics in primary staging, in biochemical recurrence and in metastasized disease. Compared to conventional imaging, 68 Ga-PSMA-11 PET/CT reaches a higher sensitivity with an excellent specificity in the clinical diagnosis of primary staging as well as staging for recurrence and advanced, metastasized disease. In biochemical recurrence, 68 Ga-PSMA-11 PET/CT shows significantly higher detection rates in comparison to choline PET/CT, especially in patients with low PSA values. In the clinical diagnosis of recurrent disease, therapy concepts were changed in more than a quarter of the patients due to the use of 68 Ga-PSMA-11 PET/CT. The significance of staging with 68 Ga-PSMA-11 PET/CT in advanced metastasized patients remains uncertain. Due to the excellent results of 68 Ga-PSMA-11 PET imaging, even in patients with slightly elevated PSA levels, it will continue to play an important role in clinical diagnostics of prostate cancer and, thus, its clinical utilization will become more widely spread.
Liang, Y Q; Cui, Z D; Zhu, S L; Li, Z Y; Yang, X J; Chen, Y J; Ma, J M
2013-11-21
In this paper, we describe the design, fabrication and gas-sensing tests of nano-coaxial p-Co3O4/n-TiO2 heterojunction. Specifically, uniform TiO2 nanotubular arrays have been assembled by anodization and used as templates for generation of the Co3O4 one-dimensional nanorods. The structure morphology and composition of as-prepared products have been characterized by SEM, XRD, TEM, and XPS. A possible growth mechanism governing the formation of such nano-coaxial heterojunctions is proposed. The TiO2 nanotube sensor shows a normal n-type response to reducing ethanol gas, whereas TiO2-Co3O4 exhibits p-type response with excellent sensing performances. This conversion of sensing behavior can be explained by the formation of p-n heterojunction structures. A possible sensing mechanism is also illustrated, which can provide theoretical guidance for the further development of advanced gas-sensitive materials with p-n heterojunction.
NASA Astrophysics Data System (ADS)
Yang, Gilmo; Kang, Sukwon; Lee, Kangjin; Kim, Giyoung; Son, Jaeryong; Mo, Changyeun
2010-04-01
The identification of pesticide and 6-benzylaminopurine (6-BAP) plant growth regulator was carried out using a label-free opto-fluidic ring resonator (OFRR) biosensor. The OFRR sensing platform is a recent advancement in opto-fluidic technology that integrates photonic sensing technology with microfluidics. It features quick detection time, small sample volume, accurate quantitative and kinetic results. The most predominant advantage of the OFRR integrated with microfluidics is that we can potentially realize the multi-channel and portable biosensor that detects numerous analytes simultaneously. Antisera for immunoassay were raised in rabbits against the 6-BAP-BSA conjugate. Using the immunization protocol and unknown cytokinin reacting with same antibody, comparable sensitivity and specificity were obtained. 6-BAP antibody was routinely used for cytokinin analysis. A sensitive and simple OFRR method with a good linear relationship was developed for the determination of 6-BAP. The detection limit was also examined. The biosensor demonstrated excellent reproducibility when periodically exposed to 6-BAP.
Catalyst-free growth of Al-doped SnO2 zigzag-nanobelts for low ppm detection of organic vapours
NASA Astrophysics Data System (ADS)
Sinha, Sudip Kumar; Ghosh, Saptarshi
2016-10-01
In this effort, we report on development of specific sensors dedicated for detection of two of these volatiles, namely ethanol and acetone, below the prescribed statutory limits. Single crystalline Al-doped SnO2 zigzag nanobelt structures were deposited on Si substrate by a catalyst-free thermal evaporation method. The Al-doped SnO2 zigzag nanostructures exhibit high sensitivity and repeatability together with coveted features like fast response and excellent stability. Structural attributes involving the crystal quality and morphology of Al-doped SnO2 zigzag nanobelts were analyzed using X-ray photoelectron spectroscopy (XPS), scanning electron microscopy and transmission electron microscopy. The microscopic images revealed formation of randomly oriented 'zigzag-like' nanobelts with characteristic width between 60 nm and 200 nm and length of 50-300 μm. The Al-doping was observed to have a discerning effect in enhancing the sensitivity in comparison to the pristine nanowires by creating excess oxygen vacancies in the crystal lattice, confirmed through XPS and PL spectra.
Microfluidics-based digital quantitative PCR for single-cell small RNA quantification.
Yu, Tian; Tang, Chong; Zhang, Ying; Zhang, Ruirui; Yan, Wei
2017-09-01
Quantitative analyses of small RNAs at the single-cell level have been challenging because of limited sensitivity and specificity of conventional real-time quantitative PCR methods. A digital quantitative PCR (dqPCR) method for miRNA quantification has been developed, but it requires the use of proprietary stem-loop primers and only applies to miRNA quantification. Here, we report a microfluidics-based dqPCR (mdqPCR) method, which takes advantage of the Fluidigm BioMark HD system for both template partition and the subsequent high-throughput dqPCR. Our mdqPCR method demonstrated excellent sensitivity and reproducibility suitable for quantitative analyses of not only miRNAs but also all other small RNA species at the single-cell level. Using this method, we discovered that each sperm has a unique miRNA profile. © The Authors 2017. Published by Oxford University Press on behalf of Society for the Study of Reproduction. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Sensitive Nonenzymatic Electrochemical Glucose Detection Based on Hollow Porous NiO
NASA Astrophysics Data System (ADS)
He, Gege; Tian, Liangliang; Cai, Yanhua; Wu, Shenping; Su, Yongyao; Yan, Hengqing; Pu, Wanrong; Zhang, Jinkun; Li, Lu
2018-01-01
Transition metal oxides (TMOs) have attracted extensive research attentions as promising electrocatalytic materials. Despite low cost and high stability, the electrocatalytic activity of TMOs still cannot satisfy the requirements of applications. Inspired by kinetics, the design of hollow porous structure is considered as a promising strategy to achieve superior electrocatalytic performance. In this work, cubic NiO hollow porous architecture (NiO HPA) was constructed through coordinating etching and precipitating (CEP) principle followed by post calcination. Being employed to detect glucose, NiO HPA electrode exhibits outstanding electrocatalytic activity in terms of high sensitivity (1323 μA mM-1 cm-2) and low detection limit (0.32 μM). The excellent electrocatalytic activity can be ascribed to large specific surface area (SSA), ordered diffusion channels, and accelerated electron transfer rate derived from the unique hollow porous features. The results demonstrate that the NiO HPA could have practical applications in the design of nonenzymatic glucose sensors. The construction of hollow porous architecture provides an effective nanoengineering strategy for high-performance electrocatalysts.
Quantitative measurement of solvation shells using frequency modulated atomic force microscopy
NASA Astrophysics Data System (ADS)
Uchihashi, T.; Higgins, M.; Nakayama, Y.; Sader, J. E.; Jarvis, S. P.
2005-03-01
The nanoscale specificity of interaction measurements and additional imaging capability of the atomic force microscope make it an ideal technique for measuring solvation shells in a variety of liquids next to a range of materials. Unfortunately, the widespread use of atomic force microscopy for the measurement of solvation shells has been limited by uncertainties over the dimensions, composition and durability of the tip during the measurements, and problems associated with quantitative force calibration of the most sensitive dynamic measurement techniques. We address both these issues by the combined use of carbon nanotube high aspect ratio probes and quantifying the highly sensitive frequency modulation (FM) detection technique using a recently developed analytical method. Due to the excellent reproducibility of the measurement technique, additional information regarding solvation shell size as a function of proximity to the surface has been obtained for two very different liquids. Further, it has been possible to identify differences between chemical and geometrical effects in the chosen systems.
Huang, Jiyong; Luo, Xiliang; Lee, Innam; Hu, Yushi; Cui, Xinyan Tracy; Yun, Minhee
2011-01-01
Single polypyrrole (PPy) nanowire-based microfluidic aptasensors were fabricated using a one-step electrochemical deposition method. The successful incorporation of the aptamers into the PPy nanowire was confirmed by fluorescence microscopy image. The microfluidic aptasensor showed responses to IgE protein solutions in the range from 0.01 nM to 100 nM, and demonstrated excellent specificity and sensitivity with faster response and rapid stabilization times (~20 s). At the lowest examined IgE concentration of 0.01nM, the microfluidic aptasensor still exhibited ~0.32% change in the conductance. The functionality of this aptasensor was able to be regenerated using an acid treatment with no major change in sensitivity. In addition, the detection of cancer biomarker MUC1 was performed using another microfluidic aptasensor, which showed a very low detection limit of 2.66 nM MUC1 compared to commercially available MUC1 diagnosis assay (800 nM). PMID:21937215
Fuentes-Rodriguez, Gema; Saez-Castillo, Antonio J; Garcia-Lopez, Luis-Joaquin
2018-08-01
The Youth Anxiety Measure-I for DSM-5 has recently been developed to assess youth's anxiety symptomatology. As social anxiety is one of the most common disorders in adolescence, this scale includes a subscale measuring social anxiety. However, psychometric properties of the YAM-5-I social anxiety subscale (YAM-5-I-SAD) in clinical samples are lacking. This paper aims to bridge the gap. The sample comprised 24 clinically diagnosed and 24 healthy control Spanish-speaking adolescents aged 14-17 years. Data revealed that the YAM-5- I-SAD yielded excellent sensitivity, which makes it particularly useful as a screening tool to early detect socially anxious adolescents. In addition, the YAM-5-I-SAD evidenced good internal consistency and construct validity. Data are limited to the social anxiety subscale. The YAM-5-I-SAD is a sensitive and specific measure to screen for adolescents with social anxiety. Copyright © 2018 Elsevier B.V. All rights reserved.
Abdulmawjood, Amir; Grabowski, Nils; Fohler, Svenja; Kittler, Sophie; Nagengast, Helga; Klein, Guenter
2014-01-01
Animal species identification is one of the primary duties of official food control. Since ostrich meat is difficult to be differentiated macroscopically from beef, therefore new analytical methods are needed. To enforce labeling regulations for the authentication of ostrich meat, it might be of importance to develop and evaluate a rapid and reliable assay. In the present study, a loop-mediated isothermal amplification (LAMP) assay based on the cytochrome b gene of the mitochondrial DNA of the species Struthio camelus was developed. The LAMP assay was used in combination with a real-time fluorometer. The developed system allowed the detection of 0.01% ostrich meat products. In parallel, a direct swab method without nucleic acid extraction using the HYPLEX LPTV buffer was also evaluated. This rapid processing method allowed detection of ostrich meat without major incubation steps. In summary, the LAMP assay had excellent sensitivity and specificity for detecting ostrich meat and could provide a sampling-to-result identification-time of 15 to 20 minutes. PMID:24963709
Soler, Maria; Estevez, M-Carmen; Villar-Vazquez, Roi; Casal, J Ignacio; Lechuga, Laura M
2016-08-03
Colorectal cancer is treatable and curable when detected at early stages. However there is a lack of less invasive and more specific screening and diagnosis methods which would facilitate its prompt identification. Blood circulating autoantibodies which are immediately produced by the immune system at tumor appearance have become valuable biomarkers for preclinical diagnosis of cancer. In this work, we present the rapid and label-free detection of colorectal cancer autoantibodies directly in blood serum or plasma using a recently developed nanoplasmonic biosensor. Our nanoplasmonic device offers sensitive and real-time quantification of autoantibodies with excellent selectivity and reproducibility, achieving limits of detection around 1 nM (150-160 ng mL(-1)). A preliminary evaluation of clinical samples of colorectal cancer patients has shown good correlation with ELISA. These results demonstrate the reliability of the nanobiosensor strategy and pave the way towards the achievement of a sensitive diagnostic tool for early detection of colorectal cancer. Copyright © 2016 Elsevier B.V. All rights reserved.
2011-01-01
Background Pemphigoids are rare diseases associated with IgG, IgE and IgA autoantibodies against collagen XVII/BP180. An entity of the pemphigoid group is the lamina lucida-type of linear IgA disease (IgA pemphigoid) characterized by IgA autoantibodies against BP180. While for the detection of IgG and IgE autoantibodies specific to collagen XVII several ELISA systems have been established, no quantitative immunoassay has been yet developed for IgA autoantibodies. Therefore, the aim of the present study was to develop an ELISA to detect IgA autoantibodies against collagen XVII in the sera of patients with pemphigoids. Methods We expressed a soluble recombinant form of the collagen XVII ectodomain in mammalian cells. Reactivity of IgA autoantibodies from patients with IgA pemphigoid was assessed by immunofluorescence microscopy and immunoblot analysis. ELISA test conditions were determined by chessboard titration experiments. The sensitivity, specificity and the cut-off were determined by receiver-operating characteristics analysis. Results The optimized assay was carried out using sera from patients with IgA pemphigoid (n = 30) and healthy donors (n = 105). By receiver operating characteristics (ROC) analysis, an area under the curve of 0.993 was calculated, indicating an excellent discriminatory capacity. Thus, a sensitivity and specificity of 83.3% and 100%, respectively, was determined for a cut-off point of 0.48. As additional control groups, sera from patients with bullous pemphigoid (n = 31) and dermatitis herpetiformis (n = 50), a disease associated with IgA autoantibodies against epidermal transglutaminase, were tested. In 26% of bullous pemphigoid patients, IgA autoantibodies recognized the ectodomain of collagen XVII. One of 50 (2%) of dermatitis herpetiformis patients sera slightly topped the cut-off value. Conclusions We developed the first ELISA for the specific and sensitive detection of serum IgA autoantibodies specific to collagen XVII in patients with pemphigoids. This immunoassay should prove a useful tool for clinical and translational research and should essentially improve the diagnosis and disease monitoring of patients with IgA pemphigoid. Moreover, our findings strongly suggest that IgA pemphigoid and IgG bullous pemphigoid represent two ends of the clinical spectrum of an immunological loss of tolerance against components of hemidesmosomes, which is mediated by both IgG and IgA autoantibodies. PMID:21619684
Mboumba Bouassa, Ralph-Sydney; Jenabian, Mohammad-Ali; Wolyec, Serge Tonen; Robin, Leman; Matta, Mathieu; Longo, Jean de Dieu; Grésenguet, Gérard; Andreoletti, Laurent; Bélec, Laurent
2016-01-01
Objectives. We evaluated the performances of Amplix real-time PCR platform developed by Biosynex (Strasbourg, France), combining automated station extraction (Amplix station 16 Dx) and real-time PCR (Amplix NG), for quantifying plasma HIV-1 RNA by lyophilized HIV-1 RNA-based Amplix reagents targeting gag and LTR, using samples from HIV-1-infected adults from Central African Republic. Results. Amplix real-time PCR assay showed low limit of detection (28 copies/mL), across wide dynamic range (1.4–10 log copies/mL), 100% sensitivity and 99% specificity, high reproducibility, and accuracy with mean bias < 5%. The assay showed excellent correlations and concordance of 95.3% with the reference HIV-1 RNA load assay (Roche), with mean absolute bias of +0.097 log copies/mL by Bland-Altman analysis. The assay was able to detect and quantify the most prevalent HIV-1 subtype strains and the majority of non-B subtypes, CRFs of HIV-1 group M, and HIV-1 groups N and O circulating in Central Africa. The Amplix assay showed 100% sensitivity and 99.6% specificity to diagnose virological failure in clinical samples from antiretroviral drug-experienced patients. Conclusions. The HIV-1 RNA-based Amplix real-time PCR platform constitutes sensitive and reliable system for clinical monitoring of HIV-1 RNA load in HIV-1-infected children and adults, particularly adapted to intermediate laboratory facilities in sub-Saharan Africa. PMID:28050283
QCM-nanomagnetic beads biosensor for lead ion detection.
Zhang, Qingli; Cui, Haixia; Xiong, Xingliang; Chen, Jun; Wang, Ying; Shen, Jia; Luo, Yiting; Chen, Longcong
2018-01-15
As lead poses a serious threat to humans even in small amounts, all kinds of lead detection sensors with high sensitivity and selectivity are being constantly improved and put forward. In this report, a novel, simple and label-free quartz crystal microbalance (QCM) biosensor is proposed for detecting lead ions (Pb 2+ ). The biosensor takes full advantage of the high specificity of GR-5 DNAzyme to Pb 2+ and the high sensitivity of QCM. In particular, nanomagnetic beads (NMBs) are used as a novel and effective mean of signal amplification in the biosensor because of their mass and their ability to enhance the inductive effect, which are very beneficial for both higher sensitivity and a lower detection limit. In practice, GR-5 DNAzyme, innovatively combined with NMBs, was modified on the gold electrode of the QCM through gold-sulfur self-assembly. When the electrode was exposed to Pb 2+ solution, DNAzyme was severed into two parts at the RNA site (rA), along with the release of NMBs, which caused a great increase in frequency shift of the QCM electrode. Finally, a perfect linear correlation between the logarithm of Pb 2+ concentration and the change in frequency was obtained from 1 pM to 50 nM, with a detection limit as low as 0.3 pM. Moreover, the biosensor shows both an average recovery of 97 ± 6% in a drinking water sample and an excellent specificity for Pb 2+ compared with other metal ions.
Chen, Bin Bin; Liu, Meng Li; Zhan, Lei; Li, Chun Mei; Huang, Cheng Zhi
2018-03-20
Highly selective and sensitive detection of guanosine 3'-diphosphate-5'-diphosphate (ppGpp), namely, the stringent in plants or microorganisms responding to strict or extreme environmental conditions such as stress and starvation, which plays an important role in gene expression, rRNA and antibiotics production, regulations of virulence of bacteria, and growth of plants, faces a great challenge owing to its extreme similarity to normal nucleotides. By modifying the surface groups of a facile two-step hydrothermal route prepared carbon dots (CDs) with terbium ions (Tb 3+ ) in this contribution, a novel fluorescent probe with excellent properties such as highly physical and chemical stability, narrow emission and excitation wavelength-independent emission was prepared. The Tb 3+ ions on the surface of CDs cannot only preserve the intrinsic fluorescence (FL) of CDs but also keep its own coordination capacity with rare earth complex, and thus the clamp structure (four phosphate groups) of ppGpp can specific binding with Tb 3+ ions on the surface of CDs to produce antenna effect. Therefore, a highly selective and sensitive fluorescent ratiometry of ppGpp was developed by terbium-modified carbon dots (CDs-Tb) with the limit of detection as low as 50 nM based on the synergistic effect of antenna effect of Tb 3+ ions and specific recognition capacity of CDs. The applicability of this assay was demonstrated by CDs-Tb-based paper sensor for high distinguishing ppGpp from other nucleotides with similar structure.
Plasmonic gold nanostar for biomedical sensing
NASA Astrophysics Data System (ADS)
Liu, Yang; Yuan, Hsiangkuo; Fales, Andrew M.; Vo-Dinh, Tuan
2014-03-01
Cancer has become one of most significant death reasons and causes approximately 7.9 million human deaths worldwide each year. The challenge to detect cancer at an early stage makes cancer-related biomarkers sensing attract more and more research interest and efforts. Surface-enhanced Raman scattering (SERS) provides a promising method for various biomarkers (DNA, RNA, protein, et al.) detection due to its high sensitivity, specificity and capability for multiple analytes detection. Raman spectroscopy is a non-destructive photon-scattering technique, which provides molecule-specific information on molecular vibrational energy levels. SERS takes advantage of plasmonic effects and can enhance Raman signal up to 1015 at "hot spots". Due to its excellent sensitivity, SERS has been capable of achieving single-molecule detection limit. Local pH environment has been identified to be a potential biomarker for cancer diagnosis since solid cancer contains highly acidic environments. A near-infrared (NIR) SERS nanoprobe based on gold nanostars for pH sensing is developed for future cancer detection. Near-infrared (NIR) light is more suitable for in vivo applications because of its low attenuation rate and tissue auto fluorescence. SERS spectrum of pH reporter under various pH environments is monitored and used for pH sensing. Furthermore, density functional theory (DFT) calculation is performed to investigate Raman spectra changes with pH at the molecular level. The study demonstrates that SERS is a sensitive tool to monitor minor molecular structural changes due to local pH environment for cancer detection.
Richter, Felicitas; Strauss, Bernhard; Braehler, Elmar; Adametz, Luise; Berger, Uwe
2017-04-01
The prevention of eating disorders and the identification of high-risk individuals are essential for the public health sector. There is need for sensitive and specific screening instruments of disordered eating that can be applied in universal samples as an initial step into disease prevention. The SCOFF is a screening instrument for disordered eating, frequently used in international and cross-cultural contexts to detect individuals at risk. The objective of this research is to evaluate whether the SCOFF can be used as a screening tool for disordered eating in universal samples. This is the first study which examined the psychometric properties of the German version of the SCOFF in a general population sample. A representative sample (N=2527) of the German population, aged 14-95years, was recruited. Psychometric properties were determined including reliability, concurrent and construct validity, and factor structure. The prevalence of disordered eating was assessed. The prevalence of disordered eating in the general population was 10%. Using the established cutoff point of ≥2, values for diagnostic accuracy were 26% (sensitivity), 97% (specificity), 80% (positive predictive value), and 74% (negative predictive value). Factorial analyses revealed an excellent model fit of a unidimensional model. Due to its low sensitivity and a high percentage of false negatives, there are limitations in using the German version of the SCOFF in general population samples with wide age ranges. Copyright © 2016 Elsevier Ltd. All rights reserved.
Fowler, J Christopher; Madan, Alok; Allen, Jon G; Patriquin, Michelle; Sharp, Carla; Oldham, John M; Frueh, B Christopher
2018-01-01
With the publication of DSM 5 alternative model for personality disorders it is critical to assess the components of the model against evidence-based models such as the five factor model and the DSM-IV-TR categorical model. This study explored the relative clinical utility of these models in screening for borderline personality disorder (BPD). Receiver operator characteristics and diagnostic efficiency statistics were calculated for three personality measures to ascertain the relative diagnostic efficiency of each measure. A total of 1653 adult inpatients at a specialist psychiatric hospital completed SCID-II interviews. Sample 1 (n=653) completed the SCID-II interviews, SCID-II Questionnaire (SCID-II-PQ) and the Big Five Inventory (BFI), while Sample 2 (n=1,000) completed the SCID-II interviews, Personality Inventory for DSM5 (PID-5) and the BFI. BFI measure evidenced moderate accuracy for two composites: High Neuroticism+ low agreeableness composite (AUC=0.72, SE=0.01, p<0.001) and High Neuroticism+ Low+Low Conscientiousness (AUC=0.73, SE=0.01, p<0.0001). The SCID-II-PQ evidenced moderate-to-excellent accuracy (AUC=0.86, SE=0.02, p<0.0001) with a good balance of specificity (SP=0.80) and sensitivity (SN=0.78). The PID-5 BPD algorithm (consisting of elevated emotional lability, anxiousness, separation insecurity, hostility, depressivity, impulsivity, and risk taking) evidenced moderate-to-excellent accuracy (AUC=0.87, SE=0.01, p<0.0001) with a good balance of specificity (SP=0.76) and sensitivity (SN=0.81). Findings generally support the use of SCID-II-PQ and PID-5 BPD algorithm for screening purposes. Furthermore, findings support the accuracy of the DSM 5 alternative model Criteria B trait constellation for diagnosing BPD. Limitations of the study include the single inpatient setting and use of two discrete samples to assess PID-5 and SCID-II-PQ. Copyright © 2017 Elsevier Inc. All rights reserved.
Gralnek, I M; Adler, S N; Yassin, K; Koslowsky, B; Metzger, Y; Eliakim, R
2008-04-01
Esophageal capsule endoscopy (ECE) provides an alternative, minimally invasive modality for evaluating the esophagus. This study evaluates the performance and test characteristics of a second-generation esophageal capsule endoscope, the PillCam ESO 2. Adults with known or suspected esophageal disease were included. Using the simplified ingestion procedure, each patient underwent capsule endoscopy with the PillCam ESO 2. Following ECE, esophagogastroduodenoscopy (EGD) was performed on the same day by an investigator who was blinded to the results of the ECE. In random order, capsule endoscopy videos were read and interpreted by the study investigator blinded to EGD results. 28 patients (19 men, 9 women; mean age 53.3 years) were included. In 82 % of the patients, at least 75 % of the Z line was visualized by the PillCam ESO 2. A per-lesion analysis demonstrated that the PillCam ESO 2 had definitive results in 30/43 lesions (69.8 %) and EGD in 29/43 (67.4 %), P value = 0.41. Compared with EGD for detecting suspected Barrett's esophagus and esophagitis, the PillCam ESO 2 had a sensitivity of 100 % and a specificity of 74 %, and a sensitivity of 80 % and a specificity of 87 %, respectively. The PillCam ESO 2 demonstrated 86 % agreement with EGD in describing the Z line (kappa statistic 0.68). The modified ingestion protocol provided excellent cleansing, with bubbles/saliva having no or only a minor effect on Z line images in 86 % of cases. The PillCam ESO 2 demonstrated excellent visualization of the Z line. Compared with standard EGD, the PillCam ESO 2 had good test characteristics with high rates of detection of suspected Barrett's esophagus and esophagitis. This study provides indirect validation of the simplified ingestion procedure. The PillCam ESO 2 acquires high quality esophageal images, performs safely, and should be able to replace the current PillCam ESO.
Taborri, Juri; Rossi, Stefano; Palermo, Eduardo; Patanè, Fabrizio; Cappa, Paolo
2014-01-01
In this work, we decided to apply a hierarchical weighted decision, proposed and used in other research fields, for the recognition of gait phases. The developed and validated novel distributed classifier is based on hierarchical weighted decision from outputs of scalar Hidden Markov Models (HMM) applied to angular velocities of foot, shank, and thigh. The angular velocities of ten healthy subjects were acquired via three uni-axial gyroscopes embedded in inertial measurement units (IMUs) during one walking task, repeated three times, on a treadmill. After validating the novel distributed classifier and scalar and vectorial classifiers-already proposed in the literature, with a cross-validation, classifiers were compared for sensitivity, specificity, and computational load for all combinations of the three targeted anatomical segments. Moreover, the performance of the novel distributed classifier in the estimation of gait variability in terms of mean time and coefficient of variation was evaluated. The highest values of specificity and sensitivity (>0.98) for the three classifiers examined here were obtained when the angular velocity of the foot was processed. Distributed and vectorial classifiers reached acceptable values (>0.95) when the angular velocity of shank and thigh were analyzed. Distributed and scalar classifiers showed values of computational load about 100 times lower than the one obtained with the vectorial classifier. In addition, distributed classifiers showed an excellent reliability for the evaluation of mean time and a good/excellent reliability for the coefficient of variation. In conclusion, due to the better performance and the small value of computational load, the here proposed novel distributed classifier can be implemented in the real-time application of gait phases recognition, such as to evaluate gait variability in patients or to control active orthoses for the recovery of mobility of lower limb joints. PMID:25184488
Sahni, A K; Nagendra, A; Roy, Partha; Patrikar, S
2014-07-01
Standard HIV testing is done using serum or plasma. FDA approved ELISA to screen urine for IgG antibodies to HIV-1 in 1996. It is a simple, noninvasive test and is appropriate for developing countries where health care personnel may not be professionally trained or where clean needles for drawing blood may not always be available. 436 individuals with high-risk behavior and strong clinical suspicion of HIV infection were screened for IgG antibodies to HIV-1 in urine by ELISA. Urine HIV testing was performed by enzyme immunoassay, at the ongoing Voluntary Confidential Counseling and Testing Center (VCCTC) at a large tertiary care microbiology lab. The individuals enrolled for the study had high-risk exposure to the virus and majorities were from a state with a high incidence of HIV infection. In all individuals, both serum and urine were tested for IgG antibodies to HIV-1. Overall, 135 individuals (30.96%) were HIV-positive, of whom 96 (71%) had never previously tested positive; 87% of those who tested positive received their results, and most were referred for medical care. Sensitivity, specificity and predictive values of HIV-1 urine ELISA test kit were determined. Sensitivity was found to be 89.6%; 95% CI [82.9-94.0], specificity 97.3%; 95% CI [94.6-98.8], positive predictive value 93.8%; 95% CI [87.8-97.1] and negative predictive value 95.4%; 95% CI [92.3-97.4]. Efficiency, sensitivity, and specificity of the urine-based screening for HIV-1 test kits were excellent as compared to the reference test.
Fananapazir, Ghaneh; Bashir, Mustafa R; Corwin, Michael T; Lamba, Ramit; Vu, Catherine T; Troppmann, Christoph
2017-03-01
To determine the accuracy of ferumoxytol-enhanced magnetic resonance angiography (MRA) in assessing the severity of transplant renal artery stenosis (TRAS), using digital subtraction angiography (DSA) as the reference standard. Our Institutional Review Board approved this retrospective, Health Insurance Portability and Accountability Act-compliant study. Thirty-three patients with documented clinical suspicion for TRAS (elevated serum creatinine, refractory hypertension, edema, and/or audible bruit) and/or concerning sonographic findings (elevated renal artery velocity and/or intraparenchymal parvus tardus waveforms) underwent a 1.5T MRA with ferumoxytol prior to DSA. All DSAs were independently reviewed by an interventional radiologist and served as the reference standard. The MRAs were reviewed by three readers who were blinded to the ultrasound and DSA findings for the presence and severity of TRAS. Sensitivity, specificity, and accuracy for identifying substantial stenoses (>50%) were determined. Intraclass correlation coefficients (ICCs) were calculated among readers. Mean differences between the percent stenosis from each MRA reader and DSA were calculated. On DSA, a total of 42 stenoses were identified in the 33 patients. The sensitivity, specificity, and accuracy of MRA in detecting substantial stenoses were 100%, 75-87.5%, and 95.2-97.6%, respectively, among the readers. There was excellent agreement among readers as to the percent stenosis (ICC = 0.82). MRA overestimated the degree of stenosis by 3.9-9.6% compared to DSA. Ferumoxytol-enhanced MRA provides high sensitivity, specificity, and accuracy for determining the severity of TRAS. Our results suggest that it can potentially be used as a noninvasive examination following ultrasound to reduce the number of unnecessary conventional angiograms. 3 J. Magn. Reson. Imaging 2017;45:779-785. © 2016 International Society for Magnetic Resonance in Medicine.
Non-Culture Diagnostics for Invasive Candidiasis: Promise and Unintended Consequences
Clancy, Cornelius J.; Nguyen, M. Hong
2018-01-01
Blood cultures are positive for Candida species in < 50% and < 20% of hematogenously disseminated and intra-abdominal candidiasis, respectively. Non-culture tests such as mannan, anti-mannan antibody, Candida albicans germ tube antibody (CAGTA), 1,3-β-d-glucan (BDG), the T2Candida nanodiagnostic panel, and polymerase chain reaction (PCR) are available for clinical use, but their roles in patient care are uncertain. Sensitivity/specificity of combined mannan/anti-mannan, BDG, T2Candida and PCR for candidemia are ~80%/80%, ~80%/80%, ~90%/98%, and ~90%/90%, respectively. Limited data for intra-abdominal candidiasis suggest CAGTA, BDG sensitivity/specificity of ~65%/75% and PCR sensitivity of ~85–90%. PCR specificity has varied widely for intra-abdominal candidiasis (33–97%), and T2Candida data are lacking. Tests will be useful if restricted to cases in which positive and negative predictive values (PPVs, NPVs) differ in a clinically meaningful way from the pre-test likelihood of invasive candidiasis. In some patients, PPVs are sufficient to justify antifungal treatment, even if blood cultures are negative. In most patients, NPVs of each test are excellent, which may support decisions to withhold antifungal therapy. If test results are not interpreted judiciously, non-culture diagnostics may have unintended consequences for stewardship and infection prevention programs. In particular, discrepant non-culture test-positive/culture-negative results may promote inappropriate antifungal treatment of patients who are unlikely to have candidiasis, and lead to spurious reporting of hospital-acquired infections. In conclusion, non-culture Candida diagnostics have potential to advance patient care, but this promise will be realized only if users understand tests’ strengths and limitations, and plan proactively for how best to employ them at their hospitals. PMID:29463043
Diagnostic accuracy and turnaround time of the Xpert MTB/RIF assay in routine clinical practice.
Kwak, Nakwon; Choi, Sun Mi; Lee, Jinwoo; Park, Young Sik; Lee, Chang-Hoon; Lee, Sang-Min; Yoo, Chul-Gyu; Kim, Young Whan; Han, Sung Koo; Yim, Jae-Joon
2013-01-01
The Xpert MTB/RIF assay was introduced for timely and accurate detection of tuberculosis (TB). The aim of this study was to determine the diagnostic accuracy and turnaround time (TAT) of Xpert MTB/RIF assay in clinical practice in South Korea. We retrospectively reviewed the medical records of patients in whom Xpert MTB/RIF assay using sputum were requested. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for the diagnosis of pulmonary tuberculosis (PTB) and detection of rifampicin resistance were calculated. In addition, TAT of Xpert MTB/RIF assay was compared with those of other tests. Total 681 patients in whom Xpert MTB/RIF assay was requested were included in the analysis. The sensitivity, specificity, PPV and NPV of Xpert MTB/RIF assay for diagnosis of PTB were 79.5% (124/156), 100.0% (505/505), 100.0% (124/124) and 94.0% (505/537), respectively. Those for the detection of rifampicin resistance were 57.1% (8/14), 100.0% (113/113), 100.0% (8/8) and 94.9% (113/119), respectively. The median TAT of Xpert MTB/RIF assay to the report of results and results confirmed by physicians in outpatient settings were 0 (0-1) and 6 (3-7) days, respectively. Median time to treatment after initial evaluation was 7 (4-9) days in patients with Xpert MTB/RIF assay, but was 21 (7-33.5) days in patients without Xpert MTB/RIF assay. Xpert MTB/RIF assay showed acceptable sensitivity and excellent specificity for the diagnosis of PTB and detection of rifampicin resistance in areas with intermediate TB burden. Additionally, the assay decreased time to the initiation of anti-TB drugs through shorter TAT.
Diagnostic Accuracy and Turnaround Time of the Xpert MTB/RIF Assay in Routine Clinical Practice
Kwak, Nakwon; Choi, Sun Mi; Lee, Jinwoo; Park, Young Sik; Lee, Chang-Hoon; Lee, Sang-Min; Yoo, Chul-Gyu; Kim, Young Whan; Han, Sung Koo; Yim, Jae-Joon
2013-01-01
The Xpert MTB/RIF assay was introduced for timely and accurate detection of tuberculosis (TB). The aim of this study was to determine the diagnostic accuracy and turnaround time (TAT) of Xpert MTB/RIF assay in clinical practice in South Korea. We retrospectively reviewed the medical records of patients in whom Xpert MTB/RIF assay using sputum were requested. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for the diagnosis of pulmonary tuberculosis (PTB) and detection of rifampicin resistance were calculated. In addition, TAT of Xpert MTB/RIF assay was compared with those of other tests. Total 681 patients in whom Xpert MTB/RIF assay was requested were included in the analysis. The sensitivity, specificity, PPV and NPV of Xpert MTB/RIF assay for diagnosis of PTB were 79.5% (124/156), 100.0% (505/505), 100.0% (124/124) and 94.0% (505/537), respectively. Those for the detection of rifampicin resistance were 57.1% (8/14), 100.0% (113/113), 100.0% (8/8) and 94.9% (113/119), respectively. The median TAT of Xpert MTB/RIF assay to the report of results and results confirmed by physicians in outpatient settings were 0 (0–1) and 6 (3–7) days, respectively. Median time to treatment after initial evaluation was 7 (4–9) days in patients with Xpert MTB/RIF assay, but was 21 (7–33.5) days in patients without Xpert MTB/RIF assay. Xpert MTB/RIF assay showed acceptable sensitivity and excellent specificity for the diagnosis of PTB and detection of rifampicin resistance in areas with intermediate TB burden. Additionally, the assay decreased time to the initiation of anti-TB drugs through shorter TAT. PMID:24204834
Is Technologist Review of Raw Data Necessary after Home Studies for Sleep Apnea?
Brown, Devin L.; Chervin, Ronald D.; Hegeman, Garnett; Smith, Melinda A.; Garcia, Nelda M.; Morgenstern, Lewis B.; Lisabeth, Lynda D.
2014-01-01
Study Objectives: As the importance of portable monitors for detection of sleep apnea increases, efficient and cost-minimizing methods for data interpretation are needed. We sought to compare in stroke patients, for whom portable studies often have particular advantages, results from a cardiopulmonary monitoring device with and without manual edits by a polysomnographic technologist. Methods: Participants in an ongoing stroke surveillance study in Corpus Christi, Texas, underwent sleep apnea assessments with the ApneaLink Plus device within 45 days of stroke onset. Recordings were analyzed by the device's software unedited, and again after edits were made to the raw data by a registered polysomnographic technologist. Sensitivity and specificity were calculated, with the edited data as the reference standard. Sleep apnea was defined by 3 different apnea-hypopnea index (AHI) thresholds: ≥ 5, ≥ 10, and ≥ 15. Results: Among 327 subjects, 54% were male, 59% were Hispanic, and the median age was 65 years (interquartile range: 57, 77). The median AHI for the unedited data was 9 (4, 22), and for the edited data was 13 (6, 27) (p < 0.01). Specificity was above 98% for each AHI cutoff, while sensitivity was 81% to 82%. For each cutoff threshold, the edited data yielded a higher proportion of positive sleep apnea screens (p < 0.01) by approximately 10% in each group. Conclusions: For stroke patients assessed with a cardiopulmonary monitoring device, manual editing by a technologist appears likely to improve sensitivity, whereas specificity of unedited data is already excellent. Citation: Brown DL; Chervin RD; Hegeman G; Smith MA; Garcia NM; Morgenstern LB; Lisabeth LD. Is technologist review of raw data necessary after home studies for sleep apnea? J Clin Sleep Med 2014;10(4):371-375. PMID:24733981
Light and portable novel device for diabetic retinopathy screening.
Ting, Daniel S W; Tay-Kearney, Mei Ling; Kanagasingam, Yogesan
2012-01-01
To validate the use of an economical portable multipurpose ophthalmic imaging device, EyeScan (Ophthalmic Imaging System, Sacramento, CA, USA), for diabetic retinopathy screening. Evaluation of a diagnostic device. One hundred thirty-six (272 eyes) were recruited from diabetic retinopathy screening clinic of Royal Perth Hospital, Western Australia, Australia. All patients underwent three-field (optic disc, macular and temporal view) mydriatic retinal digital still photography captured by EyeScan and FF450 plus (Carl Zeiss Meditec, North America) and were subsequently examined by a senior consultant ophthalmologist using the slit-lamp biomicroscopy (reference standard). All retinal images were interpreted by a consultant ophthalmologist and a medical officer. The sensitivity, specificity and kappa statistics of EyeScan and FF450 plus with reference to the slit-lamp examination findings by a senior consultant ophthalmologist. For detection of any grade of diabetic retinopathy, EyeScan had a sensitivity and specificity of 93 and 98%, respectively (ophthalmologist), and 92 and 95%, respectively (medical officer). In contrast, FF450 plus images had a sensitivity and specificity of 95 and 99%, respectively (ophthalmologist), and 92 and 96%, respectively (medical officer). The overall kappa statistics for diabetic retinopathy grading for EyeScan and FF450 plus were 0.93 and 0.95 for ophthalmologist and 0.88 and 0.90 for medical officer, respectively. Given that the EyeScan requires minimal training to use and has excellent diagnostic accuracy in screening for diabetic retinopathy, it could be potentially utilized by the primary eye care providers to widely screen for diabetic retinopathy in the community. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.
Murgatroyd, H; Ellingford, A; Cox, A; Binnie, M; Ellis, J D; MacEwen, C J; Leese, G P
2004-01-01
Aims: To assess the effects of (1) mydriasis and (2) single versus three field photography on screening for diabetic eye disease using digital photography Method: Slit lamp examination findings were compared to digital fundal photographs for the detection of any retinopathy and for referable retinopathy in 398 patients (794 eyes). A Topcon TRC-NW6S digital non-mydriatic fundus camera was used. Three photographic strategies were used: undilated single field, dilated single field, and dilated multiple fields. The photographs were presented in random order to one of two retinal screeners. For the single field photographs the screeners were masked to the use of mydriatics. In 13% of fundal photographs, grading was performed by both, rather than just one grader. Results: Mydriasis reduced the proportion of ungradable photographs from 26% to 5% (p<0.001). Neither mydriasis nor three field photography improved the sensitivity or specificity for the detection of any retinopathy or of referable retinopathy when compared with undilated single field photography. The sensitivity and specificity for detecting referable retinopathy using undilated single field photography was 77% (95% CI 71 to 84) and 95 % (95% CI 93 to 97) respectively. Using dilated single field photography the figures were 81% (95% CI 76 to 87) and 92% (95% CI 90 to 94) respectively. Using dilated three field photography the figures were 83% (95% CI 78 to 88) and 93% (95% CI 91 to 96) respectively. Intergrader reliability for the detection of referable retinopathy in gradable photographs was excellent (Kappa values 0.86–1.00). Conclusions: Mydriasis reduces the technical failure rate. Mydriasis and the three field photography as used in this study do not increase the sensitivity or specificity of detecting diabetic retinopathy. PMID:15205238
Prenatal Sonographic Predictors of Neonatal Coarctation of the Aorta.
Anuwutnavin, Sanitra; Satou, Gary; Chang, Ruey-Kang; DeVore, Greggory R; Abuel, Ashley; Sklansky, Mark
2016-11-01
To identify practical prenatal sonographic markers for the postnatal diagnosis of coarctation of the aorta. We reviewed the fetal echocardiograms and postnatal outcomes of fetal cases of suspected coarctation of the aorta seen at a single institution between 2010 and 2014. True- and false-positive cases were compared. Logistic regression analysis was used to determine echocardiographic predictors of coarctation of the aorta. Optimal cutoffs for these markers and a multivariable threshold scoring system were derived to discriminate fetuses with coarctation of the aorta from those without coarctation of the aorta. Among 35 patients with prenatal suspicion of coarctation of the aorta, the diagnosis was confirmed postnatally in 9 neonates (25.7% true-positive rate). Significant predictors identified from multivariate analysis were as follows: Z score for the ascending aorta diameter of -2 or less (P = < .001), Z score for the mitral valve annulus of -2 or less (P= .033), Zscore for the transverse aortic arch diameter of -2 or less (P= .028), and abnormal aortic valve morphologic features (P= .026). Among all variables studied, the ascending aortic Z score had the highest sensitivity (78%) and specificity (92%) for detection of coarctation of the aorta. A multivariable threshold scoring system identified fetuses with coarctation of the aorta with still greater sensitivity (89%) and only mildly decreased specificity (88%). The finding of a diminutive ascending aorta represents a powerful and practical prenatal predictor of neonatal coarctation of the aorta. A multivariable scoring system, including dimensions of the ascending and transverse aortas, mitral valve annulus, and morphologic features of the aortic valve, provides excellent sensitivity and specificity. The use of these practical sonographic markers may improve prenatal detection of coarctation of the aorta. © 2016 by the American Institute of Ultrasound in Medicine.
2016 Revisions to the 2010/2011 fibromyalgia diagnostic criteria.
Wolfe, Frederick; Clauw, Daniel J; Fitzcharles, Mary-Ann; Goldenberg, Don L; Häuser, Winfried; Katz, Robert L; Mease, Philip J; Russell, Anthony S; Russell, Irwin Jon; Walitt, Brian
2016-12-01
The provisional criteria of the American College of Rheumatology (ACR) 2010 and the 2011 self-report modification for survey and clinical research are widely used for fibromyalgia diagnosis. To determine the validity, usefulness, potential problems, and modifications required for the criteria, we assessed multiple research reports published in 2010-2016 in order to provide a 2016 update to the criteria. We reviewed 14 validation studies that compared 2010/2011 criteria with ACR 1990 classification and clinical criteria, as well as epidemiology, clinical, and databank studies that addressed important criteria-level variables. Based on definitional differences between 1990 and 2010/2011 criteria, we interpreted 85% sensitivity and 90% specificity as excellent agreement. Against 1990 and clinical criteria, the median sensitivity and specificity of the 2010/2011 criteria were 86% and 90%, respectively. The 2010/2011 criteria led to misclassification when applied to regional pain syndromes, but when a modified widespread pain criterion (the "generalized pain criterion") was added misclassification was eliminated. Based on the above data and clinic usage data, we developed a (2016) revision to the 2010/2011 fibromyalgia criteria. Fibromyalgia may now be diagnosed in adults when all of the following criteria are met: CONCLUSIONS: The fibromyalgia criteria have good sensitivity and specificity. This revision combines physician and questionnaire criteria, minimizes misclassification of regional pain disorders, and eliminates the previously confusing recommendation regarding diagnostic exclusions. The physician-based criteria are valid for individual patient diagnosis. The self-report version of the criteria is not valid for clinical diagnosis in individual patients but is valid for research studies. These changes allow the criteria to function as diagnostic criteria, while still being useful for classification. Copyright © 2016 Elsevier Inc. All rights reserved.
Blozik, Eva; Scherer, Martin; Lacruz, Maria E; Ladwig, Karl-Heinz
2013-12-23
Screening for depressive disorders in the general adult population is recommended, however, it is unclear which instruments combine user friendliness and diagnostic utility. We evaluated the test performance of a yes/no single item screener for depressive disorders ("Have you felt depressed or sad much of the time in the past year?") in comparison to the depressive disorder module of the Patient Health Questionnaire (PHQ-9). Data from 3184 participants of the population-based KORA F3 survey in Augsburg/ Germany were used to analyse sensitivity, specificity, ROC area, positive likelihood ratio (LR+), negative likelihood ratio (LR-), positive predictive value (PPV), and negative predictive value (NPV) of the single item screener in comparison with "depressive mood" and "major depressive disorder" defined according to PHQ-9 (both interviewer-administered versions). In comparison to PHQ-9 "depressive mood", sensitivity was low (46%) with an excellent specificity (94%), (PPV 76%; NPV 82%; LR + 8.04; LR- .572, ROC area .702). When using the more conservative definition for "major depressive disorder", sensitivity increased to 83% with a specificity of 88%. The PPV under the conservative definition was low (32%), but NPV was 99% (LR + 6.65; LR- .196; ROC area .852). Results varied across age groups and between males and females. The single item screener is able to moderately decrease post-test probability of major depressive disorders and to identify populations that should undergo additional, more detailed evaluation for depression. It may have limited utility in combination with additional screening tests or for selection of at-risk populations, but cannot be recommended for routine use as a screening tool in clinical practice.
Muñoz Díaz, Belén; Molina-Recio, Guillermo; Romero-Saldaña, Manuel; Redondo Sánchez, Juana; Aguado Taberné, Cristina; Arias Blanco, Carmen; Molina-Luque, Rafael; Martínez De La Iglesia, Jorge
2018-06-05
To validate the Mini Nutritional Assessment (MNA) in a Spanish population over 65 years of age with varying degrees of independence. This cross-sectional validation study used the Chang nutritional assessment method as a reference test. 248 subjects (75.4% female), with a mean age of 83, completed the study. They were classified into three groups: (i) autonomous patients who were able to take part in activities outside their home; (ii) patients who require help with daily self-care; (iii) patients living in a residential health care facility. . Three health centres and three residential care homes situated in Cordoba (Spain). The kappa values for intra-observer and inter-observer agreement were 0.870 and 0.784, respectively. The intra-class correlation coefficient intra-observer was 0.874 and the inter-observer was 0.789. The sensitivity and specificity readings for the diagnostic accuracy of MNA were 63.2% and 72.9% in the total sample, respectively. The area under the curve was 0.726. For patients in the Group A, B and C, the sensitivity was 89.3%, 60.7% and 18.8%, and the specificity was 23.3%, 56.8% and 94.1%, respectively. The results for the reliability of the survey were excellent, and its internal consistency was acceptable. The diagnostic accuracy, as measured by the sensitivity and specificity readings, was lower than that obtained with the original survey. It can therefore be considered more suitable for a population with limited autonomy, and less appropriate for independent patients. The results may not be relevant to patients outside of the Cordova region in Spain.
Lukas, Vanessa A; Fishbein, Kenneth W; Reiter, David A; Lin, Ping-Chang; Schneider, Erika; Spencer, Richard G
2015-07-01
To evaluate the sensitivity and specificity of classification of pathomimetically degraded bovine nasal cartilage at 3 Tesla and 37°C using univariate MRI measurements of both pure parameter values and intensities of parameter-weighted images. Pre- and posttrypsin degradation values of T1 , T2 , T2 *, magnetization transfer ratio (MTR), and apparent diffusion coefficient (ADC), and corresponding weighted images, were analyzed. Classification based on the Euclidean distance was performed and the quality of classification was assessed through sensitivity, specificity and accuracy (ACC). The classifiers with the highest accuracy values were ADC (ACC = 0.82 ± 0.06), MTR (ACC = 0.78 ± 0.06), T1 (ACC = 0.99 ± 0.01), T2 derived from a three-dimensional (3D) spin-echo sequence (ACC = 0.74 ± 0.05), and T2 derived from a 2D spin-echo sequence (ACC = 0.77 ± 0.06), along with two of the diffusion-weighted signal intensities (b = 333 s/mm(2) : ACC = 0.80 ± 0.05; b = 666 s/mm(2) : ACC = 0.85 ± 0.04). In particular, T1 values differed substantially between the groups, resulting in atypically high classification accuracy. The second-best classifier, diffusion weighting with b = 666 s/mm(2) , as well as all other parameters evaluated, exhibited substantial overlap between pre- and postdegradation groups, resulting in decreased accuracies. Classification according to T1 values showed excellent test characteristics (ACC = 0.99), with several other parameters also showing reasonable performance (ACC > 0.70). Of these, diffusion weighting is particularly promising as a potentially practical clinical modality. As in previous work, we again find that highly statistically significant group mean differences do not necessarily translate into accurate clinical classification rules. © 2014 Wiley Periodicals, Inc.
Perspectives on deciphering mechanisms underlying plant heat stress response and thermotolerance
Bokszczanin, Kamila L.; Fragkostefanakis, Sotirios
2013-01-01
Global warming is a major threat for agriculture and food safety and in many cases the negative effects are already apparent. The current challenge of basic and applied plant science is to decipher the molecular mechanisms of heat stress response (HSR) and thermotolerance in detail and use this information to identify genotypes that will withstand unfavorable environmental conditions. Nowadays X-omics approaches complement the findings of previous targeted studies and highlight the complexity of HSR mechanisms giving information for so far unrecognized genes, proteins and metabolites as potential key players of thermotolerance. Even more, roles of epigenetic mechanisms and the involvement of small RNAs in thermotolerance are currently emerging and thus open new directions of yet unexplored areas of plant HSR. In parallel it is emerging that although the whole plant is vulnerable to heat, specific organs are particularly sensitive to elevated temperatures. This has redirected research from the vegetative to generative tissues. The sexual reproduction phase is considered as the most sensitive to heat and specifically pollen exhibits the highest sensitivity and frequently an elevation of the temperature just a few degrees above the optimum during pollen development can have detrimental effects for crop production. Compared to our knowledge on HSR of vegetative tissues, the information on pollen is still scarce. Nowadays, several techniques for high-throughput X-omics approaches provide major tools to explore the principles of pollen HSR and thermotolerance mechanisms in specific genotypes. The collection of such information will provide an excellent support for improvement of breeding programs to facilitate the development of tolerant cultivars. The review aims at describing the current knowledge of thermotolerance mechanisms and the technical advances which will foster new insights into this process. PMID:23986766
Misra, Madhusmita; Levitsky, Lynne L.
2015-01-01
Background: Treatment with antithyroid drugs is effective in conditions of increased thyroid hormone production (mostly Graves' Disease; GD), but not in subacute thyroiditis (SAT) or autoimmune thyroiditis (AIT). Positive thyroid stimulating immunoglobulins (TSI) make GD likely. However, not all children with GD have increased TSI. Uptake studies with 123I or 99Tc (99mTc) provide accurate and rapid diagnosis but are expensive and involve radiation exposure. Our objective was to compare TSI with 99mTc uptake for diagnosis of pediatric hyperthyroidism. Methods: We performed a retrospective chart review of hyperthyroid children who had both TSI estimation and 99mTc uptake assessment at presentation. Based on subsequent laboratory studies and follow-up, 37 had GD and 10 had non-GD thyroiditis. The TSI index was considered positive (TSI+) when it was above the upper limit of normal. 99mTc uptake was considered positive (Tc+) for any uptake >0.4% and negative (and low) (Tc-) for uptake ≤0.4%. Results: Forty-seven youth (83% females), aged 12.3±4.6 years, presented with a suppressed thyrotropin (TSH) and elevated free thyroxine and total triiodothyronine. All 37 patients with GD were Tc+ (100% sensitivity and specificity). The sensitivity of TSI for diagnosing GD was 84%, and the specificity was 100%. Six patients with GD were discordant with Tc+ but TSI–. Elevated TSI correlated with Tc+ (p=0.01) with a degree of agreement (kappa) of 0.69. Conclusion: 99mTc has excellent specificity and sensitivity in diagnosing GD. Given additional costs of 99mTc (two and a half times as much as TSI), it is reasonable to reserve 99mTc uptake assessment for hyperthyroidism of unclear etiology and negative TSI. PMID:25257665
Baskaran, Charumathi; Misra, Madhusmita; Levitsky, Lynne L
2015-01-01
Treatment with antithyroid drugs is effective in conditions of increased thyroid hormone production (mostly Graves' Disease; GD), but not in subacute thyroiditis (SAT) or autoimmune thyroiditis (AIT). Positive thyroid stimulating immunoglobulins (TSI) make GD likely. However, not all children with GD have increased TSI. Uptake studies with (123)I or (99)Tc ((99m)Tc) provide accurate and rapid diagnosis but are expensive and involve radiation exposure. Our objective was to compare TSI with (99m)Tc uptake for diagnosis of pediatric hyperthyroidism. We performed a retrospective chart review of hyperthyroid children who had both TSI estimation and (99m)Tc uptake assessment at presentation. Based on subsequent laboratory studies and follow-up, 37 had GD and 10 had non-GD thyroiditis. The TSI index was considered positive (TSI+) when it was above the upper limit of normal. (99m)Tc uptake was considered positive (Tc+) for any uptake >0.4% and negative (and low) (Tc-) for uptake ≤0.4%. Forty-seven youth (83% females), aged 12.3±4.6 years, presented with a suppressed thyrotropin (TSH) and elevated free thyroxine and total triiodothyronine. All 37 patients with GD were Tc+ (100% sensitivity and specificity). The sensitivity of TSI for diagnosing GD was 84%, and the specificity was 100%. Six patients with GD were discordant with Tc+ but TSI-. Elevated TSI correlated with Tc+ (p=0.01) with a degree of agreement (kappa) of 0.69. (99m)Tc has excellent specificity and sensitivity in diagnosing GD. Given additional costs of (99m)Tc (two and a half times as much as TSI), it is reasonable to reserve (99m)Tc uptake assessment for hyperthyroidism of unclear etiology and negative TSI.
2013-01-01
Background Screening for depressive disorders in the general adult population is recommended, however, it is unclear which instruments combine user friendliness and diagnostic utility. We evaluated the test performance of a yes/no single item screener for depressive disorders (“Have you felt depressed or sad much of the time in the past year?”) in comparison to the depressive disorder module of the Patient Health Questionnaire (PHQ-9). Methods Data from 3184 participants of the population-based KORA F3 survey in Augsburg/ Germany were used to analyse sensitivity, specificity, ROC area, positive likelihood ratio (LR+), negative likelihood ratio (LR-), positive predictive value (PPV), and negative predictive value (NPV) of the single item screener in comparison with “depressive mood” and “major depressive disorder” defined according to PHQ-9 (both interviewer-administered versions). Results In comparison to PHQ-9 “depressive mood”, sensitivity was low (46%) with an excellent specificity (94%), (PPV 76%; NPV 82%; LR + 8.04; LR- .572, ROC area .702). When using the more conservative definition for “major depressive disorder”, sensitivity increased to 83% with a specificity of 88%. The PPV under the conservative definition was low (32%), but NPV was 99% (LR + 6.65; LR- .196; ROC area .852). Results varied across age groups and between males and females. Conclusions The single item screener is able to moderately decrease post-test probability of major depressive disorders and to identify populations that should undergo additional, more detailed evaluation for depression. It may have limited utility in combination with additional screening tests or for selection of at-risk populations, but cannot be recommended for routine use as a screening tool in clinical practice. PMID:24359193
Morinha, Francisco; Travassos, Paulo; Seixas, Fernanda; Santos, Nuno; Sargo, Roberto; Sousa, Luís; Magalhães, Paula; Cabral, João A; Bastos, Estela
2013-05-01
High-resolution melting (HRM) analysis is a very attractive and flexible advanced post-PCR method with high sensitivity/specificity for simple, fast and cost-effective genotyping based on the detection of specific melting profiles of PCR products. Next generation real-time PCR systems, along with improved saturating DNA-binding dyes, enable the direct acquisition of HRM data after quantitative PCR. Melting behaviour is particularly influenced by the length, nucleotide sequence and GC content of the amplicons. This method is expanding rapidly in several research areas such as human genetics, reproductive biology, microbiology and ecology/conservation of wild populations. Here we have developed a successful HRM protocol for avian sex identification based on the amplification of sex-specific CHD1 fragments. The melting curve patterns allowed efficient sexual differentiation of 111 samples analysed (plucked feathers, muscle tissues, blood and oral cavity epithelial cells) of 14 bird species. In addition, we sequenced the amplified regions of the CHD1 gene and demonstrated the usefulness of this strategy for the genotype discrimination of various amplicons (CHD1Z and CHD1W), which have small size differences, ranging from 2 bp to 44 bp. The established methodology clearly revealed the advantages (e.g. closed-tube system, high sensitivity and rapidity) of a simple HRM assay for accurate sex differentiation of the species under study. The requirements, strengths and limitations of the method are addressed to provide a simple guide for its application in the field of molecular sexing of birds. The high sensitivity and resolution relative to previous real-time PCR methods makes HRM analysis an excellent approach for improving advanced molecular methods for bird sexing. © 2013 Blackwell Publishing Ltd.
Tsai, Yun-Long; Wang, Han-Ching; Lo, Chu-Fang; Tang-Nelson, Kathy; Lightner, Donald; Ou, Bor-Rung; Hour, Ai-Ling; Tsai, Chuan-Fu; Yen, Cheng-Chi; Chang, Hsiao-Fen Grace; Teng, Ping-Hua; Lee, Pei-Yu
2014-01-01
Timely pond-side detection of white spot syndrome virus (WSSV) plays a critical role in the implementation of bio-security measures to help minimize economic losses caused by white spot syndrome disease, an important threat to shrimp aquaculture industry worldwide. A portable device, namely POCKIT™, became available recently to complete fluorescent probe-based insulated isothermal PCR (iiPCR), and automatic data detection and interpretation within one hour. Taking advantage of this platform, the IQ Plus™ WSSV Kit with POCKIT system was established to allow simple and easy WSSV detection for on-site users. The assay was first evaluated for its analytical sensitivity and specificity performance. The 95% limit of detection (LOD) of the assay was 17 copies of WSSV genomic DNA per reaction (95% confidence interval [CI], 13 to 24 copies per reaction). The established assay has detection sensitivity similar to that of OIE-registered IQ2000™ WSSV Detection and Protection System with serial dilutions of WSSV-positive Litopenaeus vannamei DNA. No cross-reaction signals were generated from infectious hypodermal and haematopoietic necrosis virus (IHHNV), monodon baculovirus (MBV), and hepatopancreatic parvovirus (HPV) positive samples. Accuracy analysis using700 L. vannamei of known WSSV infection status shows that the established assayhassensitivity93.5% (95% CI: 90.61–95.56%) and specificity 97% (95% CI: 94.31–98.50%). Furthermore, no discrepancy was found between the two assays when 100 random L. vannamei samples were tested in parallel. Finally, excellent correlation was observed among test results of three batches of reagents with 64 samples analyzed in three different laboratories. Working in a portable device, IQ Plus™ WSSV Kit with POCKIT system allows reliable, sensitive and specific on-site detection of WSSV in L. vannamei. PMID:24625894
Niedz, Randall P
2016-01-01
ARS-Media for Excel is an ion solution calculator that uses "Microsoft Excel" to generate recipes of salts for complex ion mixtures specified by the user. Generating salt combinations (recipes) that result in pre-specified target ion values is a linear programming problem. Excel's Solver add-on solves the linear programming equation to generate a recipe. Calculating a mixture of salts to generate exact solutions of complex ionic mixtures is required for at least 2 types of problems- 1) formulating relevant ecological/biological ionic solutions such as those from a specific lake, soil, cell, tissue, or organ and, 2) designing ion confounding-free experiments to determine ion-specific effects where ions are treated as statistical factors. Using ARS-Media for Excel to solve these two problems is illustrated by 1) exactly reconstructing a soil solution representative of a loamy agricultural soil and, 2) constructing an ion-based experiment to determine the effects of substituting Na+ for K+ on the growth of a Valencia sweet orange nonembryogenic cell line.
Wu, Yunqing; Zeng, Lifeng; Xiong, Ying; Leng, Yuankui; Wang, Hui; Xiong, Yonghua
2018-05-01
Herein, we present a novel sandwich fluorescence enzyme linked immunosorbent assay (ELISA) for highly sensitive detection of Hepatitis B virus surface antigen (HBsAg) based on glucose oxidase (GOx)-induced fluorescence quenching of mercaptopropionic acid-modified CdTe quantum dots (MPA-QDs). In this system, hydrogen peroxide (H 2 O 2 ) sensitive MPA-QDs was used as a signal output, and glucose oxidase (GOx) was used as label which can generate H 2 O 2 via catalytic oxidation of glucose. The proposed method showed dynamic linear detection of HBsAg both in the range of 47pgmL -1 ~ 380pgmL -1 and 0.75ngmL -1 ~ 12.12ngmL -1 . The detection limit of the proposed fluorescence ELISA was 1.16pgmL -1 , which was approximately 430-fold lower than that of horseradish peroxidase (HRP)-based conventional ELISA. The average recoveries for HBsAg-spiked serum samples ranged from 98.0% to 126.8% with the relative standard derivation below 10%, thus indicating acceptable precision and high reproducibility of the proposed fluorescence ELISA for HBsAg detection. Additionally, the developed method showed no false positive results analyzing 35 real HBsAg-negative serum samples, and exhibited excellent agreement (R 2 =0.9907) with a commercial time-resolved fluorescence immunoassay (TRFIA) kit for detecting 31 HBsAg-positive serum samples. In summary, the proposed method based on fluorescence quenching of H 2 O 2 sensitive QDs is considerably to be an excellent biodetection platform with ultrahigh sensitivity, good accuracy and excellent reliability. Copyright © 2018 Elsevier B.V. All rights reserved.
Sensitivity Analysis of the Static Aeroelastic Response of a Wing
NASA Technical Reports Server (NTRS)
Eldred, Lloyd B.
1993-01-01
A technique to obtain the sensitivity of the static aeroelastic response of a three dimensional wing model is designed and implemented. The formulation is quite general and accepts any aerodynamic and structural analysis capability. A program to combine the discipline level, or local, sensitivities into global sensitivity derivatives is developed. A variety of representations of the wing pressure field are developed and tested to determine the most accurate and efficient scheme for representing the field outside of the aerodynamic code. Chebyshev polynomials are used to globally fit the pressure field. This approach had some difficulties in representing local variations in the field, so a variety of local interpolation polynomial pressure representations are also implemented. These panel based representations use a constant pressure value, a bilinearly interpolated value. or a biquadraticallv interpolated value. The interpolation polynomial approaches do an excellent job of reducing the numerical problems of the global approach for comparable computational effort. Regardless of the pressure representation used. sensitivity and response results with excellent accuracy have been produced for large integrated quantities such as wing tip deflection and trim angle of attack. The sensitivities of such things as individual generalized displacements have been found with fair accuracy. In general, accuracy is found to be proportional to the relative size of the derivatives to the quantity itself.
Ultrahigh-Sensitivity Piezoresistive Pressure Sensors for Detection of Tiny Pressure.
Li, Hongwei; Wu, Kunjie; Xu, Zeyang; Wang, Zhongwu; Meng, Yancheng; Li, Liqiang
2018-06-20
High-sensitivity pressure sensors are crucial for the ultrasensitive touch technology and E-skin, especially at the tiny-pressure range below 100 Pa. However, it is highly challenging to substantially promote sensitivity beyond the current level at several to 200 kPa -1 and to improve the detection limit lower than 0.1 Pa, which is significant for the development of pressure sensors toward ultrasensitive and highly precise detection. Here, we develop an efficient strategy to greatly improve the sensitivity near to 2000 kPa -1 using short-channel coplanar device structure and sharp microstructure, which is systematically proposed for the first time and rationalized by the mathematic calculation and analysis. Significantly, benefiting from the ultrahigh sensitivity, the detection limit is improved to be as small as 0.075 Pa. The sensitivity and detection limit are both superior to the current levels and far surpass the function of human skin. Furthermore, the sensor shows fast response time (50 μs), excellent reproducibility and stability, and low power consumption. Remarkably, the sensor shows excellent detection capacity in the tiny-pressure range, including light-emitting diode switching with a pressure of 7 Pa, ringtone (2-20 Pa) recognition, and ultrasensitive (0.1 Pa) electronic glove. This work represents a performance and strategic progress in the field of pressure sensing.
Sawyer, Travis W; Petersburg, Ryan; Bohndiek, Sarah E
2017-04-20
Optical fiber technology is found in a wide variety of applications to flexibly relay light between two points, enabling information transfer across long distances and allowing access to hard-to-reach areas. Large-core optical fibers and light guides find frequent use in illumination and spectroscopic applications, for example, endoscopy and high-resolution astronomical spectroscopy. Proper alignment is critical for maximizing throughput in optical fiber coupling systems; however, there currently are no formal approaches to tolerancing the alignment of a light-guide coupling system. Here, we propose a Fourier alignment sensitivity (FAS) algorithm to determine the optimal tolerances on the alignment of a light guide by computing the alignment sensitivity. The algorithm shows excellent agreement with both simulated and experimentally measured values and improves on the computation time of equivalent ray-tracing simulations by two orders of magnitude. We then apply FAS to tolerance and fabricate a coupling system, which is shown to meet specifications, thus validating FAS as a tolerancing technique. These results indicate that FAS is a flexible and rapid means to quantify the alignment sensitivity of a light guide, widely informing the design and tolerancing of coupling systems.
Sawyer, Travis W.; Petersburg, Ryan; Bohndiek, Sarah E.
2017-01-01
Optical fiber technology is found in a wide variety of applications to flexibly relay light between two points, enabling information transfer across long distances and allowing access to hard-to-reach areas. Large-core optical fibers and light guides find frequent use in illumination and spectroscopic applications; for example, endoscopy and high-resolution astronomical spectroscopy. Proper alignment is critical for maximizing throughput in optical fiber coupling systems, however, there currently are no formal approaches to tolerancing the alignment of a light guide coupling system. Here, we propose a Fourier Alignment Sensitivity (FAS) algorithm to determine the optimal tolerances on the alignment of a light guide by computing the alignment sensitivity. The algorithm shows excellent agreement with both simulated and experimentally measured values and improves on the computation time of equivalent ray tracing simulations by two orders of magnitude. We then apply FAS to tolerance and fabricate a coupling system, which is shown to meet specifications, thus validating FAS as a tolerancing technique. These results indicate that FAS is a flexible and rapid means to quantify the alignment sensitivity of a light guide, widely informing the design and tolerancing of coupling systems. PMID:28430250
Parallel traveling-wave MRI: a feasibility study.
Pang, Yong; Vigneron, Daniel B; Zhang, Xiaoliang
2012-04-01
Traveling-wave magnetic resonance imaging utilizes far fields of a single-piece patch antenna in the magnet bore to generate radio frequency fields for imaging large-size samples, such as the human body. In this work, the feasibility of applying the "traveling-wave" technique to parallel imaging is studied using microstrip patch antenna arrays with both the numerical analysis and experimental tests. A specific patch array model is built and each array element is a microstrip patch antenna. Bench tests show that decoupling between two adjacent elements is better than -26-dB while matching of each element reaches -36-dB, demonstrating excellent isolation performance and impedance match capability. The sensitivity patterns are simulated and g-factors are calculated for both unloaded and loaded cases. The results on B 1- sensitivity patterns and g-factors demonstrate the feasibility of the traveling-wave parallel imaging. Simulations also suggest that different array configuration such as patch shape, position and orientation leads to different sensitivity patterns and g-factor maps, which provides a way to manipulate B(1) fields and improve the parallel imaging performance. The proposed method is also validated by using 7T MR imaging experiments. Copyright © 2011 Wiley-Liss, Inc.
A novel microRNA assay with optical detection and enzyme-free DNA circuits
NASA Astrophysics Data System (ADS)
Liao, Yuhui; Zhou, Xiaoming
2014-09-01
MicroRNAs (miRNAs) participate in the significant processes of life course, can be used as quantificational biomarkers for cellular level researches and related diseases. Conventional methods of miRNAs' quantitative detection are obsessed with low sensitivity, time and labour consuming. Otherwise, the emerging miRNAs detection approaches are mostly exposed to the expensive equipment demands and the professional operation, remains at the stage of laboratory and concept demonstration phase. Herein, we designed a novel miRNAs detection platform that based on enzyme-free DNA circuits and electrochemical luminescence (ECL). MicroRNA21 was chosen as the ideal analyte of this platform. The whole process consists of enzyme-free DNA circuits and ECL signal giving-out steps, achieves advantages of operating in constant temperature condition, without the participation of the enzyme, preferable sensitivity and specificity. Through this approach, the sensitivity achieved at 10pM. It is indicated that this miRNAs detection platform possesses potentials to be an innovation of miRNA detection technologies in routine tests. Benefits of the high penetration of ECL in well-equipped medical establishment, this approach could greatly lessen the obstacles in process of popularization and possess excellent prospects of practical application.
Yu, Xu; Zhang, Zhi-Ling; Zheng, Si-Yang
2014-01-01
A novel highly sensitive colorimetric assay for DNA detection using cascade amplification strategy based on hybridization chain reaction and enzyme-induced metallization was established. The DNA modified superparamagnetic beads were demonstrated to capture and enrich the target DNA in the hybridization buffer or human plasma. The hybridization chain reaction and enzyme-induced silver metallization on the gold nanoparticles were used as cascade signal amplification for the detection of target DNA. The metalization of silver on the gold nanoparticles induced a significant colour change from red to yellow until black depending on the concentration of the target DNA, which could be recognized by naked eyes. This method showed a good specificity for the target DNA detection, with the capabilty to discriminate single-base-pair mismatched DNA mutation (single nucleotide polymorphism). Meanwhile, this approach exhibited an excellent anti-interference capability with the convenience of the magentic seperation and washing, which enabled its usage in complex biological systems such as human blood plasma. As an added benefit, the utilization of hybridization chain reaction and enzyme-induced metallization improved detection sensitivity down to 10 pM, which is about 100-fold lower than that of traditional unamplified homogeneous assays. PMID:25500528
Tian, Liangliang; He, Gege; Cai, Yanhua; Wu, Shenping; Su, Yongyao; Yan, Hengqing; Yang, Cong; Chen, Yanling; Li, Lu
2018-02-16
Inspired by kinetics, the design of hollow hierarchical electrocatalysts through large-scale integration of building blocks is recognized as an effective approach to the achievement of superior electrocatalytic performance. In this work, a hollow, hierarchical Co 3 O 4 architecture (Co 3 O 4 HHA) was constructed using a coordinated etching and precipitation (CEP) method followed by calcination. The resulting Co 3 O 4 HHA electrode exhibited excellent electrocatalytic activity in terms of high sensitivity (839.3 μA mM -1 cm -2 ) and reliable stability in glucose detection. The high sensitivity could be attributed to the large specific surface area (SSA), ample unimpeded penetration diffusion paths and high electron transfer rate originating from the unique two-dimensional (2D) sheet-like character and hollow porous architecture. The hollow hierarchical structure also affords sufficient interspace for accommodation of volume change and structural strain, resulting in enhanced stability. The results indicate that Co 3 O 4 HHA could have potential for application in the design of non-enzymatic glucose sensors, and that the construction of hollow hierarchical architecture provides an efficient way to design highly active, stable electrocatalysts.
NASA Astrophysics Data System (ADS)
Tian, Liangliang; He, Gege; Cai, Yanhua; Wu, Shenping; Su, Yongyao; Yan, Hengqing; Yang, Cong; Chen, Yanling; Li, Lu
2018-02-01
Inspired by kinetics, the design of hollow hierarchical electrocatalysts through large-scale integration of building blocks is recognized as an effective approach to the achievement of superior electrocatalytic performance. In this work, a hollow, hierarchical Co3O4 architecture (Co3O4 HHA) was constructed using a coordinated etching and precipitation (CEP) method followed by calcination. The resulting Co3O4 HHA electrode exhibited excellent electrocatalytic activity in terms of high sensitivity (839.3 μA mM-1 cm-2) and reliable stability in glucose detection. The high sensitivity could be attributed to the large specific surface area (SSA), ample unimpeded penetration diffusion paths and high electron transfer rate originating from the unique two-dimensional (2D) sheet-like character and hollow porous architecture. The hollow hierarchical structure also affords sufficient interspace for accommodation of volume change and structural strain, resulting in enhanced stability. The results indicate that Co3O4 HHA could have potential for application in the design of non-enzymatic glucose sensors, and that the construction of hollow hierarchical architecture provides an efficient way to design highly active, stable electrocatalysts.
Single crystal CVD diamond membranes as Position Sensitive X-ray Detector
NASA Astrophysics Data System (ADS)
Desjardins, K.; Menneglier, C.; Pomorski, M.
2017-12-01
Transparent X-ray Beam Position Monitor (XBPM) has been specifically developed for low energy X-ray beamlines (1.4 keV < E < 5 keV) allowing to transmit more than 80% of 2 keV energy beam. The detector is based on a free-standing single crystal CVD diamond membrane of 4 μm thickness with position-sensitive DLC (Diamond-Like Carbon) resistive electrodes in duo-lateral configuration. The measured X-ray beam induced current (XBIC) due to the interaction of X-rays with diamond membrane allows precise monitoring of the absolute beam flux and the beam position (by the reconstruction of its center-of-gravity) at beam transmissions reaching 95%. This detector has been installed at SOLEIL synchrotron on the SIRIUS beamline monochromator output and it has shown charge collection efficiency (CCE) reaching 100% with no lag-effects and excellent beam intensity sensitivity monitoring. X-ray beam mapping of the detector showed an XBIC response inhomogeneity of less than 10% across the membrane, corresponding mainly to the measured variation of the diamond plate thickness. The measured beam position resolution is at sub-micron level depending on the beam flux and the readout electronics bandwidth.
Michiels, Sarah; De Hertogh, Willem; Truijen, Steven; November, Danny; Wuyts, Floris; Van de Heyning, Paul
2013-05-01
Cervical sensorimotor control (CSMC) becomes increasingly important in the assessment and treatment of patients with neck pain. This review aims to compare commonly used CSMC measuring methods in terms of required tasks, measuring device and clinimetric properties. A systematic review of two databases, followed by methodological quality assessment (CBO guidelines). The methodological quality of 34 included articles was generally good (five to seven out of eight), the inter-rater agreement was excellent (κw=0.966, p<0.01). Following tasks were found: head repositioning accuracy to the neutral head position (HRA-to-NHP) and to a target position (HRA-to-target), a virtual reality test, a continuous linear movement technique (CLMT) and an object following non-linear movement technique (NLMT) (The Fly™). Test-retest reliability was fair to excellent (ICC 0.35-0.87) for the HRA-to-NHP, very bad to excellent (ICC 0.01-0.90) for the HRA-to-target, fair to good (ICC 0.25-0.77) for the virtual reality test and moderate to excellent (ICC: 0.60-0.86) for The Fly™. The reliability of the CLMT was not documented. The HRA-to-NHP, The Fly™ and the CLMT can discriminate between patients with neck complaints and controls (discriminant validity). Currently, only The Fly™ can discriminate between different patient populations (post-traumatic and non-traumatic neck pain). The sensitivity, specificity and responsiveness of the methods have to be assessed in future research. The dynamic method The Fly™ appears to be more reliable than the HRA-to-NHP and is able to discriminate between different patient populations. The diagnostic potential is to be confirmed in future research. Copyright © 2012 Elsevier B.V. All rights reserved.
NPV Sensitivity Analysis: A Dynamic Excel Approach
ERIC Educational Resources Information Center
Mangiero, George A.; Kraten, Michael
2017-01-01
Financial analysts generally create static formulas for the computation of NPV. When they do so, however, it is not readily apparent how sensitive the value of NPV is to changes in multiple interdependent and interrelated variables. It is the aim of this paper to analyze this variability by employing a dynamic, visually graphic presentation using…
Ko, Hae-Youn; Kang, Si-Mook; Kim, Hee Eun; Kwon, Ho-Keun; Kim, Baek-Il
2015-05-01
Detection of approximal caries lesions can be difficult due to their anatomical position. This study aimed to assess the ability of the quantitative light-induced fluorescence-digital (QLF-D) in detecting approximal caries, and to compare the performance with those of the International Caries Detection and Assessment System II (ICDAS II) and digital radiography (DR). Extracted permanent teeth (n=100) were selected and mounted in pairs. The simulation pairs were assessed by one calibrated dentist using each detection method. After all the examinations, the teeth (n=95) were sectioned and examined histologically as gold standard. The modalities were compared in terms of sensitivity, specificity, areas under receiver operating characteristic curves (AUROC) for enamel (D1) and dentine (D3) levels. The intra-examiner reliability was assessed for all modalities. At D1 threshold, the ICDAS II presented the highest sensitivity (0.80) while the DR showed the highest specificity (0.89); however, the methods with the greatest AUC values at D1 threshold were DR and QLF-D (0.80 and 0.80 respectively). At D3 threshold, the methods with the highest sensitivity were ICDAS II and QLF-D (0.64 and 0.64 respectively) while the method with the lowest sensitivity was DR (0.50). However, with regard to the AUC values at D3 threshold, the QLF-D presented the highest value (0.76). All modalities showed to have excellent intra-examiner reliability. The newly developed QLF-D was not only able to detect proximal caries, but also showed to have comparable performance to the visual inspection and radiography in detecting proximal caries. QLF-D has the potential to be a useful detection method for proximal caries. Copyright © 2015 Elsevier Ltd. All rights reserved.
Yang, Zhen; Zhi, Shaotao; Feng, Zhu; Lei, Chong; Zhou, Yong
2018-01-01
A sensitive and innovative assay system based on a micro-MEMS-fluxgate sensor and immunomagnetic beads-labels was developed for the rapid analysis of C-reactive proteins (CRP). The fluxgate sensor presented in this study was fabricated through standard micro-electro-mechanical system technology. A multi-loop magnetic core made of Fe-based amorphous ribbon was employed as the sensing element, and 3-D solenoid copper coils were used to control the sensing core. Antibody-conjugated immunomagnetic microbeads were strategically utilized as signal tags to label the CRP via the specific conjugation of CRP to polyclonal CRP antibodies. Separate Au film substrates were applied as immunoplatforms to immobilize CRP-beads labels through classical sandwich assays. Detection and quantification of the CRP at different concentrations were implemented by detecting the stray field of CRP labeled magnetic beads using the newly-developed micro-fluxgate sensor. The resulting system exhibited the required sensitivity, stability, reproducibility, and selectivity. A detection limit as low as 0.002 μg/mL CRP with a linearity range from 0.002 μg/mL to 10 μg/mL was achieved, and this suggested that the proposed biosystem possesses high sensitivity. In addition to the extremely low detection limit, the proposed method can be easily manipulated and possesses a quick response time. The response time of our sensor was less than 5 s, and the entire detection period for CRP analysis can be completed in less than 30 min using the current method. Given the detection performance and other advantages such as miniaturization, excellent stability and specificity, the proposed biosensor can be considered as a potential candidate for the rapid analysis of CRP, especially for point-of-care platforms. PMID:29601593
Wang, Yanyun; Tao, Ye; Liu, Yi; Zhao, Yi; Song, Chao; Zhou, Bin; Wang, Tao; Gao, Linbo; Zhang, Lin; Hu, Huaizhong
2018-06-01
The current methods of monitoring the activity of lupus nephritis (LN) may cause unnecessary hospital visits or delayed immunosuppressive therapy. We aimed to find a urinary biomarker that could be developed as a home-based test for monitoring the activity of LN.Urine samples were collected immediately before a renal biopsy from patients of suspected active LN, and also from patients with inactive LN, systemic lupus erythematous without LN or healthy controls. Biomarker search was conducted on a cytokine antibody array and confirmation was done by quantitative evaluation with enzyme-linked immunosorbent assay. The Mann-Whiney test or Student t test was used to compare the levels of 9 cytokines between different groups. The sensitivity and specificity of each cytokine for diagnosis of LN was evaluated by receiver operating characteristic curve. A rapid test based on colloidal gold immunochromatography was then developed for bedside or home use. Furthermore, an experimental e-healthcare system was constructed for recording and sharing the results of the rapid test a cloud-assisted internet of things (IoT) consisting of a sensing device, an IoT device and a cloud server.Adiponectin (Acrp30), soluble intercellular cell adhesion molecule-1 (sICAM-1), neural cell adhesion molecule 1 (NCAM-1), and CD26 were significantly higher in urine samples of active LN patients. sICAM-1 appeared more sensitive and specific among these candidates. When the cut-off value of sICAM-1 was set at 1.44 ng/mL, the sensitivity reached 98.33% with a specificity at 85.71%. The sICAM-1 strip test showed comparable sensitivity of 95% and a specificity of 83.3% for assessing the LN activity. Meanwhile, the e-healthcare system was able to conveniently digitize and share the sICAM-1 rapid test results.sICAM-1 appeared to be an excellent biomarker for monitoring LN activity. The e-healthcare system with cloud-assisted IoT could assist the digitalization and sharing of the bedside or home-based sICAM-1 test results.
Accurate clinical detection of exon copy number variants in a targeted NGS panel using DECoN.
Fowler, Anna; Mahamdallie, Shazia; Ruark, Elise; Seal, Sheila; Ramsay, Emma; Clarke, Matthew; Uddin, Imran; Wylie, Harriet; Strydom, Ann; Lunter, Gerton; Rahman, Nazneen
2016-11-25
Background: Targeted next generation sequencing (NGS) panels are increasingly being used in clinical genomics to increase capacity, throughput and affordability of gene testing. Identifying whole exon deletions or duplications (termed exon copy number variants, 'exon CNVs') in exon-targeted NGS panels has proved challenging, particularly for single exon CNVs. Methods: We developed a tool for the Detection of Exon Copy Number variants (DECoN), which is optimised for analysis of exon-targeted NGS panels in the clinical setting. We evaluated DECoN performance using 96 samples with independently validated exon CNV data. We performed simulations to evaluate DECoN detection performance of single exon CNVs and to evaluate performance using different coverage levels and sample numbers. Finally, we implemented DECoN in a clinical laboratory that tests BRCA1 and BRCA2 with the TruSight Cancer Panel (TSCP). We used DECoN to analyse 1,919 samples, validating exon CNV detections by multiplex ligation-dependent probe amplification (MLPA). Results: In the evaluation set, DECoN achieved 100% sensitivity and 99% specificity for BRCA exon CNVs, including identification of 8 single exon CNVs. DECoN also identified 14/15 exon CNVs in 8 other genes. Simulations of all possible BRCA single exon CNVs gave a mean sensitivity of 98% for deletions and 95% for duplications. DECoN performance remained excellent with different levels of coverage and sample numbers; sensitivity and specificity was >98% with the typical NGS run parameters. In the clinical pipeline, DECoN automatically analyses pools of 48 samples at a time, taking 24 minutes per pool, on average. DECoN detected 24 BRCA exon CNVs, of which 23 were confirmed by MLPA, giving a false discovery rate of 4%. Specificity was 99.7%. Conclusions: DECoN is a fast, accurate, exon CNV detection tool readily implementable in research and clinical NGS pipelines. It has high sensitivity and specificity and acceptable false discovery rate. DECoN is freely available at www.icr.ac.uk/decon.
Hengartner, M P; Heekeren, K; Dvorsky, D; Walitza, S; Rössler, W; Theodoridou, A
2017-09-01
The aim of this study was to critically examine the prognostic validity of various clinical high-risk (CHR) criteria alone and in combination with additional clinical characteristics. A total of 188 CHR positive persons from the region of Zurich, Switzerland (mean age 20.5 years; 60.2% male), meeting ultra high-risk (UHR) and/or basic symptoms (BS) criteria, were followed over three years. The test battery included the Structured Interview for Prodromal Syndromes (SIPS), verbal IQ and many other screening tools. Conversion to psychosis was defined according to ICD-10 criteria for schizophrenia (F20) or brief psychotic disorder (F23). Altogether n=24 persons developed manifest psychosis within three years and according to Kaplan-Meier survival analysis, the projected conversion rate was 17.5%. The predictive accuracy of UHR was statistically significant but poor (area under the curve [AUC]=0.65, P<.05), whereas BS did not predict psychosis beyond mere chance (AUC=0.52, P=.730). Sensitivity and specificity were 0.83 and 0.47 for UHR, and 0.96 and 0.09 for BS. UHR plus BS achieved an AUC=0.66, with sensitivity and specificity of 0.75 and 0.56. In comparison, baseline antipsychotic medication yielded a predictive accuracy of AUC=0.62 (sensitivity=0.42; specificity=0.82). A multivariable prediction model comprising continuous measures of positive symptoms and verbal IQ achieved a substantially improved prognostic accuracy (AUC=0.85; sensitivity=0.86; specificity=0.85; positive predictive value=0.54; negative predictive value=0.97). We showed that BS have no predictive accuracy beyond chance, while UHR criteria poorly predict conversion to psychosis. Combining BS with UHR criteria did not improve the predictive accuracy of UHR alone. In contrast, dimensional measures of both positive symptoms and verbal IQ showed excellent prognostic validity. A critical re-thinking of binary at-risk criteria is necessary in order to improve the prognosis of psychotic disorders. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Beynon, C M; Sumnall, H R; McVeigh, J; Cole, J C; Bellis, M A
2006-10-01
Assessment of the sensitivity and specificity of two commercially available 'drug-facilitated sexual assault' drug detector kits, Drink Guard and Drink Detective. Experimental. Laboratory. Gamma hydroxybutyrate (GHB) sodium salt, ketamine hydrochloride, temazepam, flunitrazepam and diazepam were dissolved (Tween added to benzodiazepine solutions) as separate stock solutions and added to 330 ml samples of cola (Pepsi Max), beer (Stella Artois), 'alcopop' (Bacardi Breezer) and placebo (distilled water). The doses used are reported to be common in cases of intoxication. Each kit was tested 10 times for each drink/drug combination. Two blind, independent observers scored each test (presence/absence of drug) in accordance with kit instructions; chi 2 was used to compare the proportion of times raters scored tests correctly and incorrectly. Sensitivity and specificity were calculated overall, for each drink, and sensitivity was calculated for each drug. Inter-observer agreement was evaluated using the kappa statistic. While both raters were able to score significantly more tests correctly than incorrectly using Drink Detective, and one rater scored similarly using Drink Guard, the overall sensitivity of Drink Detective and Drink Guard was 69.0% (95% CI 64.2-73.5%) and 37.5% (95% CI 30.1-45.5%), respectively. Sensitivity was drink-dependent. Drink Detective was unable to detect our dose of GHB in water, with all tests scored negatively by both raters for this drink/drug combination (n = 20 negative scores). Overall, specificity was 76.6% (95% CI 71.5-81.0%) and 87.9% (95% CI 83.0-91.6%) for Drink Guard and Drink Detective, respectively, but was affected by the beverage. Inter-rater agreement was poor for Drink Guard (kappa = 0.278 +/- 0.069) but excellent for Drink Detective (kappa = 0.894 +/- 0.245). Inter-observer agreement was drug-dependent. Use of drug detector kits by the public in the night-time environment needs further investigation and may create a false sense of security (false negatives) and undue concern (false positives) among kit users.
NASA Astrophysics Data System (ADS)
Liu, Wei; Chen, Wen; Liu, Si-Jia; Jiang, Jian-Hui
2017-03-01
Small molecule probes suitable for selective and specific fluorescence imaging of some important but low-concentration intracellular reactive sulfur species such as cysteine (Cys) pose a challenge in chemical biology. We present a readily available, fast-response fluorescence probe CHCQ-Ac, with 2-(5‧-chloro-2-hydroxyl-phenyl)-6-chloro-4(3 H)-quinazolinone (CHCQ) as the fluorophore and acrylate group as the functional moiety, that enables high-selectivity and high-sensitivity for detecting Cys in both solution and biological system. After specifically reacted with Cys, the probe undergoes a seven-membered intramolecular cyclization and released the fluorophore CHCQ with excited-state intramolecular photon transfer effect. A highly fluorescent, insoluble aggregate was then formed to facilitate high-sensitivity and high-resolution imaging. The results showed that probe CHCQ-Ac affords a remarkably large Stokes shift and can detect Cys under physiological pH condition with no interference from other analytes. Moreover, this probe was proved to have excellent chemical stability, low cytotoxicity and good cell permeability. Our design of this probe provides a novel potential tool to visualize and localize cysteine in bioimaging of live cells that would greatly help to explore various Cys-related physiological and pathological cellular processes in cell biology and diagnostics.
Brosha, Eric Lanich; Romero, Christopher Jesse; Poppe, Daniel; ...
2017-10-27
Hydrogen safety sensors must meet specific performance requirements, mandated by the U.S. Department of Energy, for hydrogen fueling station monitoring. Here, we describe the long-term performance of two zirconia-based mixed potential electrochemical hydrogen gas sensors, developed specifically with a high sensitivity to hydrogen, low cross-sensitivity, and fast response time. Over a two-year period, sensors with tin-doped indium oxide and strontium doped lanthanum chromite electrodes were deployed at two stations in four field trials tests conducted in Los Angeles. The sensors documented the existence of hydrogen plumes ranging in concentration from 100 to as high as 2700 ppm in the areamore » surrounding the dispenser, consistent with depressurization from 700 bar following vehicle refueling. As expected, the hydrogen concentration reported by the mixed potential sensors was influenced by wind direction. Baseline stability testing at a Chino, CA station showed no measureable baseline drift throughout 206 days of uninterrupted data acquisition. The high baseline stability, excellent correlation with logged fueling/depressurization events, and absence of false alarms suggest that the zirconia-based mixed potential sensor platform is a good candidate for protecting hydrogen infrastructure where frequent calibrations or sensor replacement to reduce the false alarm frequency have been shown to be cost prohibitive.« less
Yoo, Doo Han; Lee, Jae Shin
2016-07-01
[Purpose] This study examined the clinical usefulness of the clock drawing test applying Rasch analysis for predicting the level of cognitive impairment. [Subjects and Methods] A total of 187 stroke patients with cognitive impairment were enrolled in this study. The 187 patients were evaluated by the clock drawing test developed through Rasch analysis along with the mini-mental state examination of cognitive evaluation tool. An analysis of the variance was performed to examine the significance of the mini-mental state examination and the clock drawing test according to the general characteristics of the subjects. Receiver operating characteristic analysis was performed to determine the cutoff point for cognitive impairment and to calculate the sensitivity and specificity values. [Results] The results of comparison of the clock drawing test with the mini-mental state showed significant differences in according to gender, age, education, and affected side. A total CDT of 10.5, which was selected as the cutoff point to identify cognitive impairement, showed a sensitivity, specificity, Youden index, positive predictive, and negative predicive values of 86.4%, 91.5%, 0.8, 95%, and 88.2%. [Conclusion] The clock drawing test is believed to be useful in assessments and interventions based on its excellent ability to identify cognitive disorders.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brosha, Eric Lanich; Romero, Christopher Jesse; Poppe, Daniel
Hydrogen safety sensors must meet specific performance requirements, mandated by the U.S. Department of Energy, for hydrogen fueling station monitoring. Here, we describe the long-term performance of two zirconia-based mixed potential electrochemical hydrogen gas sensors, developed specifically with a high sensitivity to hydrogen, low cross-sensitivity, and fast response time. Over a two-year period, sensors with tin-doped indium oxide and strontium doped lanthanum chromite electrodes were deployed at two stations in four field trials tests conducted in Los Angeles. The sensors documented the existence of hydrogen plumes ranging in concentration from 100 to as high as 2700 ppm in the areamore » surrounding the dispenser, consistent with depressurization from 700 bar following vehicle refueling. As expected, the hydrogen concentration reported by the mixed potential sensors was influenced by wind direction. Baseline stability testing at a Chino, CA station showed no measureable baseline drift throughout 206 days of uninterrupted data acquisition. The high baseline stability, excellent correlation with logged fueling/depressurization events, and absence of false alarms suggest that the zirconia-based mixed potential sensor platform is a good candidate for protecting hydrogen infrastructure where frequent calibrations or sensor replacement to reduce the false alarm frequency have been shown to be cost prohibitive.« less
The Girona Territori Cardioprotegit Project: Performance Evaluation of Public Defibrillators.
Loma-Osorio, Pablo; Nuñez, Maria; Aboal, Jaime; Bosch, Daniel; Batlle, Pau; Ruiz de Morales, Ester; Ramos, Rafael; Brugada, Josep; Onaga, Hisao; Morales, Alex; Olivet, Josep; Brugada, Ramon
2018-02-01
In recent years, public access defibrillation programs have exponentially increased the availability of automatic external defibrillators (AED) in public spaces but there are no data on their performance in our setting. We conducted a descriptive analysis of the performance of AED since the launch of a public defibrillation program in our region. A retrospective analysis was conducted of electrocardiographic tracings and the performance of AED in a public defibrillation program from June 2011 to June 2015 in the province of Girona, Spain. There were 231 AED activations. Full information was available on 188 activations, of which 82% corresponded to mobile devices and 18% to permanent devices. Asystole was the most prevalent rhythm (42%), while ventricular fibrillation accounted for 23%. The specificity of the device in identifying a shockable rhythm was 100%, but there were 8 false negatives (sensitivity 83%). There were 47 shockable rhythms, with a spontaneous circulation recovery rate of 49% (23 cases). There were no accidents related to the use of the device. Nearly half of the recorded rhythms were asystole. The AED analyzed showed excellent safety and specificity, with moderate sensitivity. Half the patients with a shockable rhythm were successfully treated by the AED. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Plasmonic crystal based solid substrate for biomedical application of SERS
NASA Astrophysics Data System (ADS)
Morasso, Carlo F.; Mehn, Dora; Picciolini, Silvia; Vanna, Renzo; Bedoni, Marzia; Gramatica, Furio; Pellacani, Paola; Frangolho, Ana; Marchesini, Gerardo; Valsesia, Andrea
2014-02-01
Surface Enhanced Raman Spectroscopy is a powerful analytical technique that combines the excellent chemical specificity of Raman spectroscopy with the good sensitivity provided by the enhancement of the signal observed when a molecule is located on (or very close to) the surface of suitable nanostructured metallic materials. The availability of cheap, reliable and easy to use SERS substrates would pave the road to the development of bioanalytical tests that can be used in clinical practice. SERS, in fact, is expected to provide not only higher sensitivity and specificity, but also the simultaneous and markedly improved detection of several targets at the same time with higher speed compared to the conventional analytical methods. Here, we present the SERS activity of 2-D plasmonic crystals made by polymeric pillars embedded in a gold matrix obtained through the combination of soft-lithography and plasma deposition techniques on a transparent substrates. The use of a transparent support material allowed us to perform SERS detection from support side opening the possibility to use these substrates in combination with microfluidic devices. In order to demonstrate the potentialities for bioanalytical applications, we used our SERS active gold surface to detect the oxidation product of apomorphine, a well-known drug molecule used in Parkinson's disease which has been demonstrated being difficult to study by traditional HPLC based approaches.
Huang, Yanyan; Khan, Mazhar; Măndoiu, Ion I.
2013-01-01
We have previously developed a software package called PrimerHunter to design primers for PCR-based virus subtyping. In this study, 9 pairs of primers were designed with PrimerHunter and successfully used to differentiate the 9 neuraminidase (NA) genes of avian influenza viruses (AIVs) in multiple PCR-based assays. Furthermore, primer pools were designed and successfully used to decrease the number of reactions needed for NA subtyping from 9 to 4. The quadruplicate primer-pool method is cost-saving, and was shown to be suitable for the NA subtyping of both cultured AIVs and uncultured AIV swab samples. The primers selected for this study showed excellent sensitivity and specificity in NA subtyping by RT-PCR, SYBR green-based Real-time PCR and Real-time RT-PCR methods. AIV RNA of 2 to 200 copies (varied by NA subtypes) could be detected by these reactions. No unspecific amplification was displayed when detecting RNAs of other avian infectious viruses such as Infectious bronchitis virus, Infectious bursal disease virus and Newcastle disease virus. In summary, this study introduced several sensitive and specific PCR-based assays for NA subtyping of AIVs and also validated again the effectiveness of the PrimerHunter tool for the design of subtyping primers. PMID:24312367
Late-night salivary cortisol measurement in the diagnosis of Cushing's syndrome.
Carroll, Ty; Raff, Hershel; Findling, James W
2008-06-01
Making a definite diagnosis of Cushing's syndrome is a challenging problem. Unsuspected Cushing's syndrome occurs in 2-3% of patients with poorly controlled diabetes, 0.5-1% with hypertension, 6-9% with incidental adrenal masses, and 11% with unexplained osteoporosis and vertebral fractures. The increasing recognition of this syndrome highlights the need for a simple, sensitive, and specific diagnostic test. Patients with Cushing's syndrome consistently do not reach a normal nadir of cortisol secretion at night. The measurement of late-night salivary cortisol levels might, therefore, provide a new diagnostic approach for this disorder. Salivary cortisol concentrations reflect those of active free cortisol in plasma and saliva samples can easily be obtained in a nonstressful environment (e.g. at home). Late-night salivary cortisol measurement yields excellent overall diagnostic accuracy for Cushing's syndrome, with a sensitivity of 92-100% and a specificity of 93-100%. Several factors can, however, make interpretation of results difficult; these factors include disturbed sleep-wake cycles, contamination of samples (particularly by topical corticosteroids), and illnesses known to cause physiologic activation of the pituitary-adrenal axis. In this Review, we discuss the methods and value of measuring salivary cortisol for the diagnosis of Cushing's syndrome, and put forward some recommendations to maximize accuracy of results.
Cavalli, Eddy; Colé, Pascale; Leloup, Gilles; Poracchia-George, Florence; Sprenger-Charolles, Liliane; El Ahmadi, Abdessadek
Developmental dyslexia is a lifelong impairment affecting 5% to 10% of the population. In French-speaking countries, although a number of standardized tests for dyslexia in children are available, tools suitable to screen for dyslexia in adults are lacking. In this study, we administered the Alouette reading test to a normative sample of 164 French university students without dyslexia and a validation sample of 83 students with dyslexia. The Alouette reading test is designed to screen for dyslexia in children, since it taps skills that are typically deficient in dyslexia (i.e., phonological skills). However, the test's psychometric properties have not previously been available, and it is not standardized for adults. The results showed that, on the Alouette test, dyslexic readers were impaired on measures of accuracy, speed, and efficiency (accuracy/reading time). We also found significant correlations between the Alouette reading efficiency and phonological efficiency scores. Finally, in terms of the Alouette test, speed-accuracy trade-offs were found in both groups, and optimal cutoff scores were determined with receiver operator characteristic curves analysis, yielding excellent discriminatory power, with 83.1% sensitivity and 100% specificity for reading efficiency. Thus, this study supports the Alouette test as a sensitive and specific screening tool for adults with dyslexia.
Zhang, Ling; Wang, Yangzhong; Tian, Qianqian; Liu, Yang; Li, Jinghong
2017-03-15
A novel ECL biosensor for cytosensing and cell surface carbohydrate expression evaluation was developed, by the integration of the peptide modified interface for highly specific carbohydrate recognition and sodium alginate loaded glucose oxidase as the signal probe with high signal amplification efficiency. A cysteine-terminated peptide self-assembled on the electrode through Au-S bond to construct a functional interface for cell capture, with decent biocompatibility and high affinity for the human breast cancer cell MCF-7. Concanavalin A lectin modified gold nanoparticles specifically recognized the cell surface carbohydrates and were absorbed on the electrode, followed by the immobilization of multiple glucose oxidase conjugated sodium alginate, which could remarkably increase the sensitivity of the biosensor with enhanced catalysis. The as-proposed ECL cytosensor was successfully applied for the detection of the MCF-7 tumor cells, whose glycans on the cell membranes are over-expressed. A low detection limit of 150cellsmL -1 was obtained, with a wide dynamic linear range from 5.0×10 2 to 5.0×10 5 cellsmL -1 . Due to the excellent sensitivity, stability and biocompatibility, the ECL biosensor would be promising in reliable diagnostics of glycan relevant biomarkers for cancer and other diseases. Copyright © 2016 Elsevier B.V. All rights reserved.
Qian, Weiguo; Tang, Yunjia; Yan, Wenhua; Sun, Ling; Lv, Haitao
2018-03-09
Kawasaki disease (KD) is the most common pediatric vasculitis. Several models have been established to predict intravenous immunoglobulin (IVIG) resistance. The present study was aimed to evaluate the efficacy of prediction models using the medical data of KD patients. We collected the medical records of patients hospitalized in the Department of Cardiology in Children's Hospital of Soochow University with a diagnosis of KD from Jan 2015 to Dec 2016. IVIG resistance was defined as recrudescent or persistent fever ≥36 h after the end of their IVIG infusion. Patients with IVIG resistance tended to be younger, have higher occurrence of rash and changes of extremities. They had higher levels of c-reactive protein, aspartate aminotransferase, neutrophils proportion (N%), total bilirubin and lower level of albumin. Our prediction model had a sensitivity of 0.72 and a specificity of 0.75. Sensitivity of Kobayashi, Egami, Kawamura, Sano and Formosa were 0.72, 0.44, 0.48, 0.20, and 0.68, respectively. Specificity of these models were 0.62, 0.82, 0.66, 0.91, and 0.48, respectively. Our prediction model had a powerful predictive value in this area, followed by Kobayashi model while all the other prediction models had less excellent performances than ours.
Dzakah, Emmanuel E; Kang, Keren; Ni, Chao; Wang, Hong; Wu, Peidian; Tang, Shixing; Wang, Jihua; Wang, Jufang; Wang, Xiaoning
2013-06-12
Most rapid diagnostic tests (RDTs) currently used for malaria diagnosis cannot distinguish the various Plasmodium infections. The development of a Plasmodium vivax specific RDTs with high sensitivity to sufficiently differentiate the two most common Plasmodium infections would be very crucial for disease treatment and control. Plasmodium vivax aldolase gene (PvALDO) was amplified from the extracted genomic DNA and constructed into pET30a vector. Plasmodium vivax aldolase protein was successfully expressed in Escherichia coli in soluble form and the overall purity was over 95% after one-step affinity chromatography purification. The purified products were used for the immunization of mice and rabbits. Rabbit polyclonal antibodies generated were deployed to develop a novel antibody-capture ELISA for hybridoma screening. Three PvALDO specific mAbs (14C7, 15F1 and 5H7) with high affinities were selected and used in immunochromatographic test strips. Clinical blood samples (n=190) collected from Yunnan (China) were used for evaluation and the RDT's sensitivity for P. vivax was 98.33% (95% Confidence Interval (CI): 91.03% to 99.72%) compared with microscopic examination. There was specificity of 99.23% (95% CI: 95.77% to 99.87%) for P. vivax. Only one Plasmodium falciparum sample was detected among the P. falciparum samples (n=20). All Plasmodium malariae samples (n=2) as well as healthy uninfected samples (n=108) were negative. Overall performance of this RDT was excellent with positive predictive value (PPV) and negative predictive value (NPV) of 98.33% and 99.23%, respectively, at 95% CI and a very good correlation with microscopic observations (kappa value, K=0.9757). Test strips show high sensitivity even at 6.25 ng/ml of recombinant P. vivax aldolase (rPvALDO). This study further elucidates the possibility of developing aldolase-specific RDTs which can differentiate the different Plasmodium infections and improve accurate diagnosis of malaria. This RDT could adequately differentiate between P. vivax and P. falciparum infections. The novel mAb screening method developed here could find application in the screening of highly specific antibodies against other antigens.
2013-01-01
Background Most rapid diagnostic tests (RDTs) currently used for malaria diagnosis cannot distinguish the various Plasmodium infections. The development of a Plasmodium vivax specific RDTs with high sensitivity to sufficiently differentiate the two most common Plasmodium infections would be very crucial for disease treatment and control. Method Plasmodium vivax aldolase gene (PvALDO) was amplified from the extracted genomic DNA and constructed into pET30a vector. Plasmodium vivax aldolase protein was successfully expressed in Escherichia coli in soluble form and the overall purity was over 95% after one-step affinity chromatography purification. The purified products were used for the immunization of mice and rabbits. Rabbit polyclonal antibodies generated were deployed to develop a novel antibody-capture ELISA for hybridoma screening. Results Three PvALDO specific mAbs (14C7, 15F1 and 5H7) with high affinities were selected and used in immunochromatographic test strips. Clinical blood samples (n=190) collected from Yunnan (China) were used for evaluation and the RDT’s sensitivity for P. vivax was 98.33% (95% Confidence Interval (CI): 91.03% to 99.72%) compared with microscopic examination. There was specificity of 99.23% (95% CI: 95.77% to 99.87%) for P. vivax. Only one Plasmodium falciparum sample was detected among the P. falciparum samples (n=20). All Plasmodium malariae samples (n=2) as well as healthy uninfected samples (n=108) were negative. Overall performance of this RDT was excellent with positive predictive value (PPV) and negative predictive value (NPV) of 98.33% and 99.23%, respectively, at 95% CI and a very good correlation with microscopic observations (kappa value, K=0.9757). Test strips show high sensitivity even at 6.25 ng/ml of recombinant P. vivax aldolase (rPvALDO). Conclusion This study further elucidates the possibility of developing aldolase-specific RDTs which can differentiate the different Plasmodium infections and improve accurate diagnosis of malaria. This RDT could adequately differentiate between P. vivax and P. falciparum infections. The novel mAb screening method developed here could find application in the screening of highly specific antibodies against other antigens. PMID:23758950
The Advanced Gamma-ray Imaging System (AGIS)-Science Highlights
NASA Astrophysics Data System (ADS)
Buckley, J.; Coppi, P.; Digel, S.; Funk, S.; Krawczynski, H.; Krennrich, F.; Pohl, M.; Romani, R.; Vassiliev, V.
2008-12-01
The Advanced Gamma-ray Imaging System (AGIS), a future gamma-ray telescope consisting of an array of ~50 atmospheric Cherenkov telescopes distributed over an area of ~1 km2, will provide a powerful new tool for exploring the high-energy universe. The order-of-magnitude increase in sensitivity and improved angular resolution could provide the first detailed images of γ-ray emission from other nearby galaxies or galaxy clusters. The large effective area will provide unprecedented sensitivity to short transients (such as flares from AGNs and GRBs) probing both intrinsic spectral variability (revealing the details of the acceleration mechanism and geometry) as well as constraining the high-energy dispersion in the velocity of light (probing the structure of spacetime and Lorentz invariance). A wide field of view (~4 times that of current instruments) and excellent angular resolution (several times better than current instruments) will allow for an unprecedented survey of the Galactic plane, providing a deep unobscured survey of SNRs, X-ray binaries, pulsar-wind nebulae, molecular cloud complexes and other sources. The differential flux sensitivity of ~10-13 erg cm-2 sec-1 will rival the most sensitive X-ray instruments for these extended Galactic sources. The excellent capabilities of AGIS at energies below 100 GeV will provide sensitivity to AGN and GRBs out to cosmological redshifts, increasing the number of AGNs detected at high energies from about 20 to more than 100, permitting population studies that will provide valuable insights into both a unified model for AGN and a detailed measurement of the effects of intergalactic absorption from the diffuse extragalactic background light. A new instrument with fast-slewing wide-field telescopes could provide detections of a number of long-duration GRBs providing important physical constraints from this new spectral component. The new array will also have excellent background rejection and very large effective area, providing the very high sensitivity needed to detect emission from dark matter annihilation in Galactic substructure or nearby Dwarf spheroidal galaxies.
Philanthropic Donor Perspectives on Supporting Nursing Excellence in a Community Hospital.
Fickley, Sharon K; Mishler, Ray R; Black, Amelia S; DeGuzman, Pam B
2016-11-01
The purpose of this research is to explore donors' perspectives on support of nursing excellence in a community hospital. Philanthropic support is rapidly becoming critical to support nursing excellence in hospitals, including continuing education, nursing research, and professional development. However, no research has examined the experience of private donors who support nursing programs in community hospitals. Structured interviews were conducted with individuals with a history of providing significant financial support (gifts >$50 000) targeted specifically for nursing in a 176- bed community hospital in the southeastern United States. Analysis was performed using descriptive content analysis. Four themes emerged that centered around making a difference, helping nurses meet new challenges, an existing foundation of service, and valuing excellent nursing care received. This research provides specific information that nursing administrators can use when seeking philanthropic gifts to support nursing excellence programs in US community hospitals.
Ying, Na; Ju, Chuanjing; Sun, Xiuwei; Li, Letian; Chang, Hongbiao; Song, Guangping; Li, Zhongyi; Wan, Jiayu; Dai, Enyong
2017-01-01
MicroRNAs (miRNAs) constitute novel biomarkers for various diseases. Accurate and quantitative analysis of miRNA expression is critical for biomedical research and clinical theranostics. In this study, a method was developed for sensitive and specific detection of miRNAs via dual signal amplification based on duplex specific nuclease (DSN) and hybridization chain reaction (HCR). A reporter probe (RP), comprising recognition sequence (3' end modified with biotin) for a target miRNA of miR-21 and capture sequence (5' end modified with Fam) for HCR product, was designed and synthesized. HCR was initiated by partial sequence of initiator probe (IP), the other part of which can hybridize with capture sequence of RP, and was assembled by hairpin probes modified with biotin (H1-bio and H2-bio). A miR-21 triggered cyclical DSN cleavage of RP, which was immobilized to a streptavidin (SA) coated magnetic bead (MB). The released Fam labeled capture sequence then hybridized with the HCR product to generate a detectable dsDNA. This polymer was then dropped on lateral flow strip and positive result was observed. The proposed method allowed quantitative sequence-specific detection of miR-21 (with a detection limit of 2.1 fM, S/N = 3) in a dynamic range from 100 fM to 100 pM, with an excellent ability to discriminate differences in miRNAs. The method showed acceptable testing recoveries for the determination of miRNAs in serum.
Grayson, Peter C; Tomasson, Gunnar; Cuthbertson, David; Carette, Simon; Hoffman, Gary S; Khalidi, Nader A; Langford, Carol A; McAlear, Carol A; Monach, Paul A; Seo, Philip; Warrington, Kenneth J; Ytterberg, Steven R; Merkel, Peter A
2012-02-01
To assess the utility of the vascular physical examination to detect arteriographic lesions in patients with established large vessel vasculitis (LVV), including Takayasu's arteritis (TAK) and giant cell arteritis (GCA). In total, 100 patients (TAK = 68, GCA = 32) underwent standardized physical examination and angiography of the carotid, subclavian, and axillary arteries. Sensitivity and specificity were calculated for the association between findings on physical examination focusing on the vascular system (absent pulse, bruit, and blood pressure difference) and arteriographic lesions defined as stenosis, occlusion, or aneurysm. We found 67% of patients had at least 1 abnormality on physical examination (74% TAK, 53% GCA). Arteriographic lesions were seen in 76% of patients (82% TAK, 63% GCA). Individual physical examination findings had poor sensitivity (range 14%-50%) and good-excellent specificity (range 71%-98%) to detect arteriographic lesions. Even when considering physical examination findings in combination, at least 30% of arteriographic lesions were missed. Specificity improved (range 88%-100%) if individual physical examination findings were compared to a broader region of vessels rather than specific anatomically correlated vessels and if ≥ 1 physical examination findings were combined. In patients with established LVV, physical examination alone is worthwhile to detect arterial disease but does not always localize or reveal the full extent of arteriographic lesions. Abnormal vascular system findings on physical examination are highly associated with the presence of arterial lesions, but normal findings on physical examination do not exclude the possibility of arterial disease. Serial angiographic assessment is advisable to monitor arterial disease in patients with established LVV.
GRAYSON, PETER C.; TOMASSON, GUNNAR; CUTHBERTSON, DAVID; CARETTE, SIMON; HOFFMAN, GARY S.; KHALIDI, NADER A.; LANGFORD, CAROL A.; McALEAR, CAROL A.; MONACH, PAUL A.; SEO, PHILIP; WARRINGTON, KENNETH J.; YTTERBERG, STEVEN R.; MERKEL, PETER A.
2013-01-01
Objective To assess the utility of the vascular physical examination to detect arteriographic lesions in patients with established large vessel vasculitis (LVV), including Takayasu’s arteritis (TAK) and giant cell arteritis (GCA). Methods In total, 100 patients (TAK = 68, GCA = 32) underwent standardized physical examination and angiography of the carotid, subclavian, and axillary arteries. Sensitivity and specificity were calculated for the association between findings on physical examination focusing on the vascular system (absent pulse, bruit, and blood pressure difference) and arteriographic lesions defined as stenosis, occlusion, or aneurysm. Results We found 67% of patients had at least 1 abnormality on physical examination (74% TAK, 53% GCA). Arteriographic lesions were seen in 76% of patients (82% TAK, 63% GCA). Individual physical examination findings had poor sensitivity (range 14%–50%) and good-excellent specificity (range 71%–98%) to detect arteriographic lesions. Even when considering physical examination findings in combination, at least 30% of arteriographic lesions were missed. Specificity improved (range 88%–100%) if individual physical examination findings were compared to a broader region of vessels rather than specific anatomically correlated vessels and if ≥ 1 physical examination findings were combined. Conclusion In patients with established LVV, physical examination alone is worthwhile to detect arterial disease but does not always localize or reveal the full extent of arteriographic lesions. Abnormal vascular system findings on physical examination are highly associated with the presence of arterial lesions, but normal findings on physical examination do not exclude the possibility of arterial disease. Serial angiographic assessment is advisable to monitor arterial disease in patients with established LVV. PMID:22174204
Clinical applications of MS-based protein quantification.
Sabbagh, Bassel; Mindt, Sonani; Neumaier, Michael; Findeisen, Peter
2016-04-01
Mass spectrometry-based assays are increasingly important in clinical laboratory medicine and nowadays are already commonly used in several areas of routine diagnostics. These include therapeutic drug monitoring, toxicology, endocrinology, pediatrics, and microbiology. Accordingly, some of the most common analyses are therapeutic drug monitoring of immunosuppressants, vitamin D, steroids, newborn screening, and bacterial identification. However, MS-based quantification of peptides and proteins for routine diagnostic use is rather rare up to now despite excellent analytical specificity and good sensitivity. Here, we want to give an overview over current fit-for-purpose assays for MS-based protein quantification. Advantages as well as challenges of this approach will be discussed with focus on feasibility for routine diagnostic use. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Aptamer Based Microsphere Biosensor for Thrombin Detection
Zhu, Hongying; Suter, Jonathan D.; White, Ian M.; Fan, Xudong
2006-01-01
We have developed an optical microsphere resonator biosensor using aptamer as receptor for the measurement of the important biomolecule thrombin. The sphere surface is modified with anti-thrombin aptamer, which has excellent binding affinity and selectivity for thrombin. Binding of the thrombin at the sphere surface is monitored by the spectral position of the microsphere's whispering gallery mode resonances. A detection limit on the order of 1 NIH Unit/mL is demonstrated. Control experiments with non-aptamer oligonucleotide and BSA are also carried out to confirm the specific binding between aptamer and thrombin. We expect that this demonstration will lead to the development of highly sensitive biomarker sensors based on aptamer with lower cost and higher throughput than current technology.
Zhang, Da-wei; Zhao, Ming-ming; He, Hong-qiu; Guo, Shun-xing
2013-09-15
HIV-1 integrase, an essential enzyme for retroviral replication, is a validated target for anti-HIV therapy development. The catalytic core domain of integrase (IN-CCD) is capable of catalyzing disintegration reaction. In this work, a hairpin-shaped disintegration substrate was designed and validated by enzyme-linked immunosorbent assay; a molecular beacon-based assay was developed for disintegration reaction of IN-CCD. Results showed that the disintegration substrate could be recognized and catalyzed by IN-CCD, and the disintegration reaction can be monitored according to the increase of fluorescent signal. The assay can be applied to real-time detection of disintegration with advantages of simplicity, high sensitivity, and excellent specificity. Copyright © 2013 Elsevier Inc. All rights reserved.
Discrimination and classification of acute lymphoblastic leukemia cells by Raman spectroscopy
NASA Astrophysics Data System (ADS)
Managò, Stefano; Valente, Carmen; Mirabelli, Peppino; De Luca, Anna Chiara
2015-05-01
Currently, a combination of technologies is typically required to identify and classify leukemia cells. These methods often lack the specificity and sensitivity necessary for early and accurate diagnosis. Here, we demonstrate the use of Raman spectroscopy to identify normal B cells, collected from healthy patients, and three ALL cell lines (RS4;11, REH and MN60 at different differentiation level, respectively). Raman markers associated with DNA and protein vibrational modes have been identified that exhibit excellent discriminating power for leukemia cell identification. Principal Component Analysis was finally used to confirm the significance of these markers for identify leukemia cells and classifying the data. The obtained results indicate a sorting accuracy of 96% between the three leukemia cell lines.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prohl, Christopher; Lenz, Andrea, E-mail: alenz@physik.tu-berlin.de; Döscher, Henning
2016-05-15
In a fundamental cross-sectional scanning tunneling microscopy investigation on epitaxially grown GaP layers on a Si(001) substrate, differently oriented antiphase boundaries are studied. They can be identified by a specific contrast and by surface step edges starting/ending at the position of an antiphase boundary. Moreover, a change in the atomic position of P and Ga atoms along the direction of growth is observed in agreement with the structure model of antiphase boundaries in the GaP lattice. This investigation opens the perspective to reveal the orientation and position of the antiphase boundaries at the atomic scale due to the excellent surfacemore » sensitivity of this method.« less
NASA Astrophysics Data System (ADS)
Chiu, Nan-Fu; Huang, Teng-Yi; Kuo, Chun-Chuan
2015-05-01
We describe a fundamental study on the plasmonic properties and advanced biosensing mechanisms of functionalized graphene. We discuss a specific design using modified carboxyl groups, which can modulate surface plasmon (SP) coupling and provide an advantage for their binding to the sensing layer with high-performance affinity in an immunological reaction. The functionalized graphene-based surface plasmon resonance (SPR) biosensors have three advantages: high performance, high sensitivity, and excellent molecular kinetic response. In the future, functionalized graphene sheets will make a unique contribution to photonic and SPR diagnosis devices. We wish to highlight the essential characteristics of functionalized graphene-based SPR biosensors to assist researchers in developing and advancing suitable biosensors for unique applications.
Wan, Zhi; Ostendorff, Heather P; Liu, Ziying; Schneider, Lynda C; Rothschild, Kenneth J; Lim, Mark J
2018-01-01
Multiplex serological immunoassays, such as implemented on microarray or microsphere-based platforms, provide greater information content and higher throughput, while lowering the cost and blood volume required. These features are particularly attractive in pediatric food allergy testing to facilitate high throughput multi-allergen analysis from finger- or heel-stick collected blood. However, the miniaturization and microfluidics necessary for creating multiplex assays make them highly susceptible to the "matrix effect" caused by interference from non-target agents in serum and other biofluids. Such interference can result in lower sensitivity, specificity, reproducibility and quantitative accuracy. These problems have in large part prevented wide-spread implementation of multiplex immunoassays in clinical laboratories. We report the development of a novel method to eliminate the matrix effect by utilizing photocleavable capture antibodies to purify and concentrate blood-based biomarkers (a process termed PC-PURE) prior to detection in a multiplex immunoassay. To evaluate this approach, it was applied to blood-based allergy testing. Patient total IgE was purified and enriched using PC-PURE followed by multiplex microsphere-based detection of allergen-specific IgEs (termed the AllerBead assay). AllerBead was formatted to detect the eight most common pediatric food allergens: milk, soy, wheat, egg, peanuts, tree nuts, fin fish and shellfish, which account for >90% of all pediatric food allergies. 205 serum samples obtained from Boston Children's Hospital were evaluated. When PC-PURE was employed with AllerBead, excellent agreement was obtained with the standard, non-multiplex, ImmunoCAP® assay (average sensitivity above published negative predictive cutoffs = 96% and average Pearson r = 0.90; average specificity = 97%). In contrast, poor ImmunoCAP®-correlation was observed when PC-PURE was not utilized (average sensitivity above published negative predictive cutoffs = 59% and average Pearson r = 0.61; average specificity = 97%). This approach should be adaptable to improve a wide range of multiplex immunoassays such as in cancer, infectious disease and autoimmune disease.
Wan, Zhi; Ostendorff, Heather P.; Liu, Ziying; Schneider, Lynda C.; Rothschild, Kenneth J.
2018-01-01
Multiplex serological immunoassays, such as implemented on microarray or microsphere-based platforms, provide greater information content and higher throughput, while lowering the cost and blood volume required. These features are particularly attractive in pediatric food allergy testing to facilitate high throughput multi-allergen analysis from finger- or heel-stick collected blood. However, the miniaturization and microfluidics necessary for creating multiplex assays make them highly susceptible to the “matrix effect” caused by interference from non-target agents in serum and other biofluids. Such interference can result in lower sensitivity, specificity, reproducibility and quantitative accuracy. These problems have in large part prevented wide-spread implementation of multiplex immunoassays in clinical laboratories. We report the development of a novel method to eliminate the matrix effect by utilizing photocleavable capture antibodies to purify and concentrate blood-based biomarkers (a process termed PC-PURE) prior to detection in a multiplex immunoassay. To evaluate this approach, it was applied to blood-based allergy testing. Patient total IgE was purified and enriched using PC-PURE followed by multiplex microsphere-based detection of allergen-specific IgEs (termed the AllerBead assay). AllerBead was formatted to detect the eight most common pediatric food allergens: milk, soy, wheat, egg, peanuts, tree nuts, fin fish and shellfish, which account for >90% of all pediatric food allergies. 205 serum samples obtained from Boston Children’s Hospital were evaluated. When PC-PURE was employed with AllerBead, excellent agreement was obtained with the standard, non-multiplex, ImmunoCAP® assay (average sensitivity above published negative predictive cutoffs = 96% and average Pearson r = 0.90; average specificity = 97%). In contrast, poor ImmunoCAP®-correlation was observed when PC-PURE was not utilized (average sensitivity above published negative predictive cutoffs = 59% and average Pearson r = 0.61; average specificity = 97%). This approach should be adaptable to improve a wide range of multiplex immunoassays such as in cancer, infectious disease and autoimmune disease. PMID:29389948
Simplifying the assessment of coronary artery stenosis by enhancing instantaneous wave free ratio.
Spagnoli, Vincent; Picard, Fabien; Tadros, Victor-Xavier; Cournoyer, Daniel; Doucet, Serge; Tanguay, Jean François; Gosselin, Gilbert; de Guise, Pierre; Gallo, Richard
2018-04-01
Instantaneous wave free ratio (iFR) does not require adenosine, but has a relatively wide intermediate range where functional assessment remains inconclusive. In this pilot study, we sought to enhance iFR through with the use of intracoronary (IC) saline (iFRs) and contrast media (iFRc) and determine whether these techniques correlated well with fractional flow reserve (FFR). Patients with coronary artery stenosis (CAS) associated with an iFR in the intermediate zone (≥0.86 and ≤0.93) were prospectively assessed with resting distal coronary pressure/aorta pressure (Pd/Pa), iFR, iFRs, iFRc and FFR. A total of 40 coronary lesions were studied (40 patients). Pearson correlation coefficients for FFR and iFR, FFR and iFRs, FFR and iFRc were respectively: 0.57 (P=0.0002), 0.80 (P<0.0001) and 0.77 (P<0.0001). Receiver-operating characteristic (ROC) curve analysis showed similar area under the curve (AUC) of iFRs and iFR [0.90 (95% CI: 0.76-1) vs. 0.89 (95% CI: 0.79-0.99), P=0.89]. Youden's index established cut-off values of ≤0.90 for iFR (sensitivity =91%, specificity =74%) and ≤0.78 for iFRs (sensitivity =73%, specificity =100%). In contrast, the AUC of iFRc was superior to the AUC of iFR [0.99 (95% CI: 0.98-1), P=0.049]. iFRc showed excellent accuracy and established cut-off values of ≤0.81 in predicting an FFR value of ≤0.80 (sensitivity =100%, specificity =93%). When iFR is in the intermediate zone, functional assessment of CAS by iFR is enhanced with the use of contrast media but not saline. This pilot study could be hypothesis generating for further study to enhance iFR specificity and sensibility.
Simplifying the assessment of coronary artery stenosis by enhancing instantaneous wave free ratio
Spagnoli, Vincent; Picard, Fabien; Tadros, Victor-Xavier; Cournoyer, Daniel; Doucet, Serge; Tanguay, Jean François; Gosselin, Gilbert; de Guise, Pierre
2018-01-01
Background Instantaneous wave free ratio (iFR) does not require adenosine, but has a relatively wide intermediate range where functional assessment remains inconclusive. In this pilot study, we sought to enhance iFR through with the use of intracoronary (IC) saline (iFRs) and contrast media (iFRc) and determine whether these techniques correlated well with fractional flow reserve (FFR). Methods Patients with coronary artery stenosis (CAS) associated with an iFR in the intermediate zone (≥0.86 and ≤0.93) were prospectively assessed with resting distal coronary pressure/aorta pressure (Pd/Pa), iFR, iFRs, iFRc and FFR. Results A total of 40 coronary lesions were studied (40 patients). Pearson correlation coefficients for FFR and iFR, FFR and iFRs, FFR and iFRc were respectively: 0.57 (P=0.0002), 0.80 (P<0.0001) and 0.77 (P<0.0001). Receiver-operating characteristic (ROC) curve analysis showed similar area under the curve (AUC) of iFRs and iFR [0.90 (95% CI: 0.76–1) vs. 0.89 (95% CI: 0.79–0.99), P=0.89]. Youden’s index established cut-off values of ≤0.90 for iFR (sensitivity =91%, specificity =74%) and ≤0.78 for iFRs (sensitivity =73%, specificity =100%). In contrast, the AUC of iFRc was superior to the AUC of iFR [0.99 (95% CI: 0.98–1), P=0.049]. iFRc showed excellent accuracy and established cut-off values of ≤0.81 in predicting an FFR value of ≤0.80 (sensitivity =100%, specificity =93%). Conclusions When iFR is in the intermediate zone, functional assessment of CAS by iFR is enhanced with the use of contrast media but not saline. This pilot study could be hypothesis generating for further study to enhance iFR specificity and sensibility. PMID:29850406
School Management by Wandering Around.
ERIC Educational Resources Information Center
Frase, Larry; Hetzel, Robert
Management by wandering around (MBWA) is the catalyst that brings teachers, aides, parents, and administrators together in the pursuit of excellent schools. This book, based on common sense and hundreds of years of experience, offers specific strategies and techniques for using MBWA to obtain excellence. The building blocks of school excellence,…
Wu, Wei; Chen, Junhua; Fang, Zhiyuan; Ge, Chenchen; Xiang, Zhicheng; Ouyang, Chuanyan; Lie, Puchang; Xiao, Zhuo; Yu, Luxin; Wang, Lin; Zeng, Lingwen
2013-12-04
Polymerase-free and label-free strategies for DNA detection have shown excellent sensitivity and specificity in various biological samples. Herein, we propose a method for single nucleotide polymorphism (SNP) detection by using self-assembled DNA concatemers. Capture probes, bound to magnetic beads, can joint mediator probes by T4 DNA ligase in the presence of target DNA that is complementary to the capture probe and mediator probe. The mediator probes trigger self-assembly of two auxiliary probes on magnetic beads to form DNA concatemers. Separated by a magnetic rack, the double-stranded concatemers on beads can recruit a great amount of SYBR Green I and eventually result in amplified fluorescent signals. In comparison with reported methods for SNP detection, the concatemer-based approach has significant advantages of low background, simplicity, and ultrasensitivity, making it as a convenient platform for clinical applications. As a proof of concept, BRAF(T1799A) oncogene mutation, a SNP involved in diverse human cancers, was used as a model target. The developed approach using a fluorescent intercalator can detect as low as 0.1 fM target BRAF(T1799A) DNA, which is better than those previously published methods for SNP detection. This method is robust and can be used directly to measure the BRAF(T1799A) DNA in complex human serum with excellent recovery (94-103%). It is expected that this assay principle can be directed toward other SNP genes by simply changing the mediator probe and auxiliary probes. Copyright © 2013 Elsevier B.V. All rights reserved.
CA resist with high sensitivity and sub-100-nm resolution for advanced mask making
NASA Astrophysics Data System (ADS)
Huang, Wu-Song; Kwong, Ranee W.; Hartley, John G.; Moreau, Wayne M.; Angelopoulos, Marie; Magg, Christopher; Lawliss, Mark
2000-07-01
Recently, there is significant interest in using CA resist for electron beam (E-beam) applications including mask making, direct write, and projection printing. CA resists provide superior lithographic performance in comparison to traditional non-CA E-beam resist in particular high contrast, resolution, and sensitivity. However, most of the commercially available CA resist have the concern of airborne base contaminants and sensitivity to PAB and/or PEB temperatures. In this presentation, we will discuss a new improved ketal resists system referred to as KRS-XE which exhibits excellent lithography, is robust toward airborne base, compatible with 0.263N TMAH aqueous developer and exhibits excellent lithography, is robust toward airborne base, compatible with 0.263N TMAH aqueous developer and exhibits a large PAB/PEB latitude. With the combination of a high performance mask making E-beam exposure tool, high kV shaped beam system EL4+ and the KRS-XE resist, we have printed 75nm lines/space feature with excellent profile control at a dose of 13(mu) C/cm2 at 75kV. The shaped beam vector scan system used here provides a unique property in resolving small features in lithography and throughput. Overhead in EL4+$ limits the systems ability to fully exploit the sensitivity of the new resist for throughput. The EL5 system has sufficiently low overhead that it is projected to print a 4X, 16G DRAM mask with OPC in under 3 hours with the CA resist. We will discuss the throughput advantages of the next generation EL5 system over the existing EL4+.
Waszkiewicz, Napoleon; Zalewska-Szajda, Beata; Chojnowska, Sylwia; Szajda, Sławomir Dariusz; Zalewska, Anna; Konarzewska, Beata; Szulc, Agata; Wojtulewska-Supron, Aleksandra; Kępka, Alina; Knaś, Małgorzata; Ładny, Jerzy Robert; Milewski, Robert; Zwierz, Krzysztof
2013-01-01
Background. Severe periodontitis leading to tooth loss is found in 5–15% of most populations worldwide. Aim. The applicability of salivary β-hexosaminidase (β-HEX A%, percentage of β-HEX A isoenzyme to total β-HEX) and β-HEX B% (β-HEX B/β-HEX) indexes was investigated as a possible marker of periodontitis. Methods. Thirty three alcohol-dependent smokers (AS) and 32 healthy controls (C) were enrolled in the study. The activity of β-HEX was measured spectrophotometrically. Results. β-HEX A% was significantly higher and β-HEX B% was lower in AS than in C group. We found a significant correlation between β-HEX A% and gingival index (GI) and an inverse correlation between β-HEX A% and salivary flow (SF), in all groups. Salivary β-HEX A% index in smoking alcoholics at 0.23 had excellent sensitivity (96%) and specificity (91%); the AUC for β-HEX A% was high (0.937). There were no correlations between amount/duration-time of alcohol drinking/smoking and β-HEX A% or β-HEX B%. We found significant correlations between the time period of denture wearing and GI, papilla bleeding index (PBI), and decayed missing filled teeth index (DMFT) and between GI and the amount of smoked cigarettes per day. Conclusion. Bad periodontal state was most likely due to the nicotine dependence. Salivary β-HEX A% is a promising excellent marker for the diagnosis of periodontitis. PMID:24288426
European validation of Real-Time PCR method for detection of Salmonella spp. in pork meat.
Delibato, Elisabetta; Rodriguez-Lazaro, David; Gianfranceschi, Monica; De Cesare, Alessandra; Comin, Damiano; Gattuso, Antonietta; Hernandez, Marta; Sonnessa, Michele; Pasquali, Frédérique; Sreter-Lancz, Zuzsanna; Saiz-Abajo, María-José; Pérez-De-Juan, Javier; Butrón, Javier; Prukner-Radovcic, Estella; Horvatek Tomic, Danijela; Johannessen, Gro S; Jakočiūnė, Džiuginta; Olsen, John E; Chemaly, Marianne; Le Gall, Francoise; González-García, Patricia; Lettini, Antonia Anna; Lukac, Maja; Quesne, Segolénè; Zampieron, Claudia; De Santis, Paola; Lovari, Sarah; Bertasi, Barbara; Pavoni, Enrico; Proroga, Yolande T R; Capuano, Federico; Manfreda, Gerardo; De Medici, Dario
2014-08-01
The classical microbiological method for detection of Salmonella spp. requires more than five days for final confirmation, and consequently there is a need for an alternative methodology for detection of this pathogen particularly in those food categories with a short shelf-life. This study presents an international (at European level) ISO 16140-based validation study of a non-proprietary Real-Time PCR-based method that can generate final results the day following sample analysis. It is based on an ISO compatible enrichment coupled to an easy and inexpensive DNA extraction and a consolidated Real-Time PCR assay. Thirteen laboratories from seven European Countries participated to this trial, and pork meat was selected as food model. The limit of detection observed was down to 10 CFU per 25 g of sample, showing excellent concordance and accordance values between samples and laboratories (100%). In addition, excellent values were obtained for relative accuracy, specificity and sensitivity (100%) when the results obtained for the Real-Time PCR-based methods were compared to those of the ISO 6579:2002 standard method. The results of this international trial demonstrate that the evaluated Real-Time PCR-based method represents an excellent alternative to the ISO standard. In fact, it shows an equal and solid performance as well as it reduces dramatically the extent of the analytical process, and can be easily implemented routinely by the Competent Authorities and Food Industry laboratories. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Chen, Yajing; Xiong, Zhichao; Zhang, Lingyi; Zhao, Jiaying; Zhang, Quanqing; Peng, Li; Zhang, Weibing; Ye, Mingliang; Zou, Hanfa
2015-02-01
Highly selective and efficient capture of glycosylated proteins and peptides from complex biological samples is of profound significance for the discovery of disease biomarkers in biological systems. Recently, hydrophilic interaction liquid chromatography (HILIC)-based functional materials have been extensively utilized for glycopeptide enrichment. However, the low amount of immobilized hydrophilic groups on the affinity material has limited its specificity, detection sensitivity and binding capacity in the capture of glycopeptides. Herein, a novel affinity material was synthesized to improve the binding capacity and detection sensitivity for glycopeptides by coating a poly(2-(methacryloyloxy)ethyl)-dimethyl-(3-sulfopropyl) ammonium hydroxide (PMSA) shell onto Fe3O4@SiO2 nanoparticles, taking advantage of reflux-precipitation polymerization for the first time (denoted as Fe3O4@SiO2@PMSA). The thick polymer shell endows the nanoparticles with excellent hydrophilic property and several functional groups on the polymer chains. The resulting Fe3O4@SiO2@PMSA demonstrated an outstanding ability for glycopeptide enrichment with high selectivity, extremely high detection sensitivity (0.1 fmol), large binding capacity (100 mg g-1), high enrichment recovery (above 73.6%) and rapid magnetic separation. Furthermore, in the analysis of real complicated biological samples, 905 unique N-glycosylation sites from 458 N-glycosylated proteins were reliably identified in three replicate analyses of a 65 μg protein sample extracted from mouse liver, showing the great potential of Fe3O4@SiO2@PMSA in the detection and identification of low-abundance N-linked glycopeptides in biological samples.Highly selective and efficient capture of glycosylated proteins and peptides from complex biological samples is of profound significance for the discovery of disease biomarkers in biological systems. Recently, hydrophilic interaction liquid chromatography (HILIC)-based functional materials have been extensively utilized for glycopeptide enrichment. However, the low amount of immobilized hydrophilic groups on the affinity material has limited its specificity, detection sensitivity and binding capacity in the capture of glycopeptides. Herein, a novel affinity material was synthesized to improve the binding capacity and detection sensitivity for glycopeptides by coating a poly(2-(methacryloyloxy)ethyl)-dimethyl-(3-sulfopropyl) ammonium hydroxide (PMSA) shell onto Fe3O4@SiO2 nanoparticles, taking advantage of reflux-precipitation polymerization for the first time (denoted as Fe3O4@SiO2@PMSA). The thick polymer shell endows the nanoparticles with excellent hydrophilic property and several functional groups on the polymer chains. The resulting Fe3O4@SiO2@PMSA demonstrated an outstanding ability for glycopeptide enrichment with high selectivity, extremely high detection sensitivity (0.1 fmol), large binding capacity (100 mg g-1), high enrichment recovery (above 73.6%) and rapid magnetic separation. Furthermore, in the analysis of real complicated biological samples, 905 unique N-glycosylation sites from 458 N-glycosylated proteins were reliably identified in three replicate analyses of a 65 μg protein sample extracted from mouse liver, showing the great potential of Fe3O4@SiO2@PMSA in the detection and identification of low-abundance N-linked glycopeptides in biological samples. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr05955g
Yoon, Min A; Kim, Se Hyung; Lee, Jeong Min; Woo, Hyoun Sik; Lee, Eun Sun; Ahn, Se Jin; Han, Joon Koo
2012-01-01
To evaluate the diagnostic performance of computed tomography (CT) colonography (CTC) reconstructed with different levels of adaptive statistical iterative reconstruction (ASiR, GE Healthcare) and Veo (model-based iterative reconstruction, GE Healthcare) at various tube currents in detection of polyps in porcine colon phantoms. Five porcine colon phantoms with 46 simulated polyps were scanned at different radiation doses (10, 30, and 50 mA s) and were reconstructed using filtered back projection (FBP), ASiR (20%, 40%, and 60%) and Veo. Eleven data sets for each phantom (10-mA s FBP, 10-mA s 20% ASiR, 10-mA s 40% ASiR, 10-mA s 60% ASiR, 10-mA s Veo, 30-mA s FBP, 30-mA s 20% ASiR, 30-mA s 40% ASiR, 30-mA s 60% ASiR, 30-mA s Veo, and 50-mA s FBP) yielded a total of 55 data sets. Polyp detection sensitivity and confidence level of 2 independent observers were evaluated with the McNemar test, the Fisher exact test, and receiver operating characteristic curve analysis. Comparative analyses of overall image quality score, measured image noise, and interpretation time were also performed. Per-polyp detection sensitivities and specificities were highest in 10-mA s Veo, 30-mA s FBP, 30-mA s 60% ASiR, and 50-mA s FBP (sensitivity, 100%; specificity, 100%). The area-under-the-curve values for the overall performance of each data set was also highest (1.000) at 50-mA s FBP, 30-mA s FBP, 30-mA s 60% ASiR, and 10-mA s Veo. Images reconstructed with ASiR showed statistically significant improvement in per-polyp detection sensitivity as the percent level of per-polyp sensitivity increased (10-mA s FBP vs 10-mA s 20% ASiR, P = 0.011; 10-mA s FBP vs 10-mA s 40% ASiR, P = 0.000; 10-mA s FBP vs 10-mA s 60% ASiR, P = 0.000; 10-mA s 20% ASiR vs 40% ASiR, P = 0.034). Overall image quality score was highest at 30-mA s Veo and 50-mA s FBP. The quantitative measurement of the image noise was lowest at 30-mA s Veo and second lowest at 10-mA s Veo. There was a trend of decrease in time required for image interpretation as the percent level of ASiR increased, and ASiR or Veo was used instead of FBP. However, differences from comparative analyses of overall image quality score, measured image noise, and interpretation time did not reach statistical significance. ASiR and Veo showed improved diagnostic performance with excellent sensitivity and specificity with less image noise and good image quality compared with FBP reconstruction of same radiation dose. Our study confirmed feasibility of low-dose CTC with iterative reconstruction as a promising screening tool with excellent diagnostic performance similar to that of the standard-dose CTC with FBP.
Garritsen, H S; Probst-Kepper, M; Legath, N; Eberl, W; Samaniego, S; Woudenberg, J; Schuitemaker, J H N; Kroll, H; Gurney, D A; Moore, G W; Zehnder, J L
2014-04-01
Heparin-induced thrombocytopenia (HIT) is a life-threatening condition, in which the anticoagulant heparin, platelet factor 4 (PF4), and platelet-activating antibodies form complexes with prothrombotic properties. Laboratory tests to support clinical diagnosis are subdivided into functional, platelet activation assays, which lack standardization, or immunological assays, which have moderate specificity toward HIT. In this study, clinical performance of HITAlert, a novel in vitro diagnostic (IVD) registered platelet activation assay, was tested in a large cohort of HIT-suspected patients and compared with immunological assays. From 346 HIT-suspected patients (single center), clinical data including 4T pretest probability results, citrated platelet-poor plasmas, and sera were collected, allowing direct comparison of clinical observations with HITAlert results. HITAlert performance was compared with PF4 IgG ELISA (246 patients, three centers) and PF4 PaGIA (298 patients, single center). HITAlert showed high sensitivity (88.2%) and specificity (99.1%) when compared with clinical diagnosis. Agreement of HITAlert with PF4 ELISA- and PF4 PaGIA-positive patients is low (52.7 and 23.2%, respectively), while agreement with PF4 IgG ELISA- and PF4 PaGIA-negative patients is very high (98.1 and 99.1%, respectively). HITAlert performance is excellent when compared with clinical HIT diagnosis, making it a suitable assay for rapid testing of platelet activation due to anticoagulant therapy. © 2013 John Wiley & Sons Ltd.
DNA Clutch Probes for Circulating Tumor DNA Analysis.
Das, Jagotamoy; Ivanov, Ivaylo; Sargent, Edward H; Kelley, Shana O
2016-08-31
Progress toward the development of minimally invasive liquid biopsies of disease is being bolstered by breakthroughs in the analysis of circulating tumor DNA (ctDNA): DNA released from cancer cells into the bloodstream. However, robust, sensitive, and specific methods of detecting this emerging analyte are lacking. ctDNA analysis has unique challenges, since it is imperative to distinguish circulating DNA from normal cells vs mutation-bearing sequences originating from tumors. Here we report the electrochemical detection of mutated ctDNA in samples collected from cancer patients. By developing a strategy relying on the use of DNA clutch probes (DCPs) that render specific sequences of ctDNA accessible, we were able to readout the presence of mutated ctDNA. DCPs prevent reassociation of denatured DNA strands: they make one of the two strands of a dsDNA accessible for hybridization to a probe, and they also deactivate other closely related sequences in solution. DCPs ensure thereby that only mutated sequences associate with chip-based sensors detecting hybridization events. The assay exhibits excellent sensitivity and specificity in the detection of mutated ctDNA: it detects 1 fg/μL of a target mutation in the presence of 100 pg/μL of wild-type DNA, corresponding to detecting mutations at a level of 0.01% relative to wild type. This approach allows accurate analysis of samples collected from lung cancer and melanoma patients. This work represents the first detection of ctDNA without enzymatic amplification.
Pape, Marcy M; Williams, Kathy; Kodosky, Paula N; Dretsch, Michael
2016-01-01
To compare the capacity of the Community Balance and Mobility Scale (CB&M) to identify balance and mobility deficits in Service Members (SMs) with mild traumatic brain injury and comorbid psychological health conditions (mTBI/PH) to other commonly used balance assessments. A clinical research institute that provides a 4-week, outpatient, interdisciplinary program for active-duty SMs with mTBI/PH. A nonrandomized, cross-sectional design that compared multiple measures between 2 groups-active duty SMs with (n = 8) and without (n = 8) the dual diagnosis of mTBI/PH. Gait speed, Activities-specific Balance Confidence scale (ABC), Functional Gait Assessment (FGA), and CB&M to assess functional balance among the community-dwelling, TBI population. Across all measures, the mTBI/PH group performed significantly worse (P ≤ .01) with the exception of the FGA. The abilities of all objective measures to distinguish participants with mTBI/PH from healthy controls ranged from fair to excellent (area under the curve [AUC] = 0.66-0.94). However, the CB&M showed the largest group differences in effect size (d = 2.6) and had the highest discriminate ability (AUC = 0.98; sensitivity 100%; specificity 88%). The CB&M appears to have higher sensitivity and specificity than other measures of balance in SMs with mTBI/PH. A higher cut score for the CB&M is needed for this population.
Testa, A; Kaijser, J; Wynants, L; Fischerova, D; Van Holsbeke, C; Franchi, D; Savelli, L; Epstein, E; Czekierdowski, A; Guerriero, S; Fruscio, R; Leone, F P G; Vergote, I; Bourne, T; Valentin, L; Van Calster, B; Timmerman, D
2014-08-12
To compare different ultrasound-based international ovarian tumour analysis (IOTA) strategies and risk of malignancy index (RMI) for ovarian cancer diagnosis using a meta-analysis approach of centre-specific data from IOTA3. This prospective multicentre diagnostic accuracy study included 2403 patients with 1423 benign and 980 malignant adnexal masses from 2009 until 2012. All patients underwent standardised transvaginal ultrasonography. Test performance of RMI, subjective assessment (SA) of ultrasound findings, two IOTA risk models (LR1 and LR2), and strategies involving combinations of IOTA simple rules (SRs), simple descriptors (SDs) and LR2 with and without SA was estimated using a meta-analysis approach. Reference standard was histology after surgery. The areas under the receiver operator characteristic curves of LR1, LR2, SA and RMI were 0.930 (0.917-0.942), 0.918 (0.905-0.930), 0.914 (0.886-0.936) and 0.875 (0.853-0.894). Diagnostic one-step and two-step strategies using LR1, LR2, SR and SD achieved summary estimates for sensitivity 90-96%, specificity 74-79% and diagnostic odds ratio (DOR) 32.8-50.5. Adding SA when IOTA methods yielded equivocal results improved performance (DOR 57.6-75.7). Risk of Malignancy Index had sensitivity 67%, specificity 91% and DOR 17.5. This study shows all IOTA strategies had excellent diagnostic performance in comparison with RMI. The IOTA strategy chosen may be determined by clinical preference.
NASA Astrophysics Data System (ADS)
Liu, Jing; Gao, Shan; Kang, Lin; Ji, Bin; Xin, Wenwen; Kang, Jingjing; Li, Ping; Gao, Jie; Wang, Hanbin; Wang, Jinglin; Yang, Hao
2017-03-01
Botulism is a severe and potentially lethal paralytic disease caused by several botulinum neurotoxin-producing Clostridia spp. In China, the majority of the cases caused by botulism were from less-developed rural areas. Here, we designed specific substrate peptides and reconfigured gold nanoparticle-based lateral flow test strip (LFTS) to develop an endopeptidase-based lateral flow assay for the diagnosis of botulism. We performed this lateral flow assay on botulinum neurotoxin-spiked human serum samples. The as-prepared LFTS had excellent performance in the detection of botulinum neurotoxin using only 1 μL of simulated serum, and its sensitivity and specificity were comparable to that of mouse lethality assay. Moreover, the assay takes only half a day and does not require highly trained laboratory staff, specialized facility, or equipment. Finally, our LFTS can be potentially extended to other serotypes of BoNTs by designing specific substrate peptides against the different types of BoNTs. Overall, we demonstrate a strategy by which LFTS and endopeptidase activity assays can be integrated to achieve facile and economic diagnosis of botulism in resource-limited settings.
Levine, R L; Fromm, R E; Mojtahedzadeh, M; Baghaie, A A; Opekun, A R
1994-06-01
To compare the accuracy of litmus paper-determined gastric pH to a nasogastric graphite antimony pH probe. A prospective clinical trial of gastric pH determination in patients enrolled in a study of histamine-2-receptor (H2) antagonists. The medical intensive care unit (ICU) of a 450-bed county hospital. Critically ill ICU patients requiring stress ulcer prophylaxis. Using a crossover design, the patients were randomized to initially receive an H2 antagonist by continuous infusion or intravenous bolus, and subsequently were crossed over to the other limb of the study. Gastric pH was determined using pH-sensitive litmus paper at the initiation of each limb of the study and at 1, 2, 4, and 8 hrs after the initiation of H2 receptor antagonist therapy. In addition, gastric pH was continuously determined over the same time period utilizing a graphite antimony pH probe. Gastric pH measurements determined with litmus paper and intragastric pH probes demonstrated an excellent correlation (r2 = .93, p < .001). McNemar's test of correlated proportions could not demonstrate a significant difference between the two monitoring methods (chi-square = 0.5, p > .47), and the kappa statistic (0.95, p < .001) demonstrated excellent concordance. Bias measurement was 0.01 (95% confidence interval = -0.155 to 0.176). Measurement of intragastric pH, using pH-sensitive litmus paper, is both sensitive and specific when utilizing a graphite antimony nasogastric pH probe as a reference standard. Litmus paper-determined gastric pH testing is both easy to perform and inexpensive. Therefore, based on the current data, we believe this technique (i.e., litmus paper determined gastric pH testing) to be the method of choice for determination of intragastric pH in patients at risk for stress gastric ulcers in the medical ICU.
Wu, Daxian; Tao, Shuhui; Liu, Shuiping; Zhou, Jiebin; Tan, Deming; Hou, Zhouhua
2017-07-28
To observe the sensitivity of transcription mediated amplification (TMA), and to compare its performance with real-time reverse transcription polymerase chain reaction (real-time RT-PCR) in detecting human immunodeficiency virus RNA (HIV RNA). Methods: TMA system was established with TaqMan probes, specific primers, moloney murine leukemia virus (MMLV) reverse transcriptase, T7 RNA polymerase, and reaction substrates. The sensitivity of TMA was evaluated by amplifying a group of 10-fold diluted HIV RNA standards which were transcribed in vitro. A total of 60 plasma of HIV infected patients were measured by TMA and Cobas Amplicor HIV-1 Monitor test to observe the positive rate. The correlation and concordance of the above two technologies were investigated by linear regression and Bland-Altman analysis. Results: TMA system was established successfully and HIV RNA transcribed standards at concentration of equal or more than 10 copies/mL could be detected by TMA technology. Among 60 samples of plasma from HIV infected patients, 46 were positively detected and 12 were negatively amplified by both TMA and Cobas reagents; 2 samples were positively tested by Cobas reagent but negatively tested by TMA system. The concordance rate of the two methods was 97.1% and the difference of positive detection rate between the two methods was not statistically significant (P>0.05). Linear regression was used for 46 samples which were positively detected by both TMA and Cobas reagents and showed an excellent correlation between the two reagents (r=0.997, P<0.001). Bland-Altma analysis revealed that the mean different value of HIV RNA levels for denary logarithm was 0.02. Forty-four samples were included in 95% of credibility interval of concordance. Conclusion: TMA system has the potential of high sensitivity. TMA and real-time RT-PCR keep an excellent correlation and consistency in detecting HIV RNA.
Highly efficient and compatible shampoo for use after hair transplant
Schweiger, Dorothea; Schoelermann, Andrea M; Filbry, Alexander; Hamann, Tina; Moser, Claudia; Rippke, Frank
2015-01-01
Background Sensitive or hyperreactive skin is a common condition defined by prickling, burning, pain, and pruritus. Although this skin problem was initially described on the face, the scalp is often affected. A sensitive scalp can react with irritation to harsh surfactants or other additives which are often present in shampoos. For this reason, we developed a new rinse-off hypertolerant shampoo specifically designed for the hypersensitive and problematic scalp. Methods The shampoo formulation is based on an extremely mild surfactant system and contains bisabolol, an anti-irritant and anti-inflammatory ingredient of chamomile. The shampoo is free of additives such as perfumes, silicones, colorants, parabens, paraffins, and betaine. Since skin can remain in a hyperreactive state after wounding, the status after hair transplantation was chosen as a model system to test the shampoo. Scalp condition and compatibility of each volunteer were analyzed by a plastic surgeon directly after hair transplant and after stitch removal. The plastic surgeons also rated whether they would recommend the further use of the test shampoo. Additionally, volunteers completed a self-assessment questionnaire. Results Following hair transplantation, regular use of the shampoo resulted in a significant reduction in the extent of scabbing and erythema. This was confirmed by dermatological scalp examinations performed by the plastic surgeon as well as in volunteers’ self-assessments. The plastic surgeon highly recommended the further use of the test shampoo after hair transplant to all study participants. Conclusion Application of the test shampoo demonstrated excellent skin compatibility and product efficacy after hair transplant. The test shampoo significantly reduced the extent of scabs and erythema. Therefore, the shampoo is ideally suited for use after hair transplantation and for the treatment of sensitive scalp. The excellent skin compatibility is because of the mild surfactant system, the calming ingredient bisabolol, and the absence of potentially irritating ingredients. PMID:26229498
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wehrschuetz, M., E-mail: martin.wehrschuetz@klinikum-graz.at; Aschauer, M.; Portugaller, H.
The purpose of this study was to assess interobserver variability and accuracy in the evaluation of renal artery stenosis (RAS) with gadolinium-enhanced MR angiography (MRA) and digital subtraction angiography (DSA) in patients with hypertension. The authors found that source images are more accurate than maximum intensity projection (MIP) for depicting renal artery stenosis. Two independent radiologists reviewed MRA and DSA from 38 patients with hypertension. Studies were postprocessed to display images in MIP and source images. DSA was the standard for comparison in each patient. For each main renal artery, percentage stenosis was estimated for any stenosis detected by themore » two radiologists. To calculate sensitivity, specificity and accuracy, MRA studies and stenoses were categorized as normal, mild (1-39%), moderate (40-69%) or severe ({>=}70%), or occluded. DSA stenosis estimates of 70% or greater were considered hemodynamically significant. Analysis of variance demonstrated that MIP estimates of stenosis were greater than source image estimates for both readers. Differences in estimates for MIP versus DSA reached significance in one reader. The interobserver variance for MIP, source images and DSA was excellent (0.80< {kappa}{<=} 0.90). The specificity of source images was high (97%) but less for MIP (87%); average accuracy was 92% for MIP and 98% for source images. In this study, source images are significantly more accurate than MIP images in one reader with a similar trend was observed in the second reader. The interobserver variability was excellent. When renal artery stenosis is a consideration, high accuracy can only be obtained when source images are examined.« less
Grant, Jon E; Kim, Suck Won; McCabe, James S
2006-06-01
Kleptomania presents difficulties in diagnosis for clinicians. This study aimed to develop and test a DSM-IV-based diagnostic instrument for kleptomania. To assess for current kleptomania the Structured Clinical Interview for Kleptomania (SCI-K) was administered to 112 consecutive subjects requesting psychiatric outpatient treatment for a variety of disorders. Reliability and validity were determined. Classification accuracy was examined using the longitudinal course of illness. The SCI-K demonstrated excellent test-retest (Phi coefficient = 0.956 (95% CI = 0.937, 0.970)) and inter-rater reliability (phi coefficient = 0.718 (95% CI = 0.506, 0.848)) in the diagnosis of kleptomania. Concurrent validity was observed with a self-report measure using DSM-IV kleptomania criteria (phi coefficient = 0.769 (95% CI = 0.653, 0.850)). Discriminant validity was observed with a measure of depression (point biserial coefficient = -0.020 (95% CI = -0.205, 0.166)). The SCI-K demonstrated both high sensitivity and specificity based on longitudinal assessment. The SCI-K demonstrated excellent reliability and validity in diagnosing kleptomania in subjects presenting with various psychiatric problems. These findings require replication in larger groups, including non-psychiatric populations, to examine their generalizability. Copyright (c) 2006 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Xiao, Jiajia; Li, Po; Wen, Xiaogang
2018-04-01
Novel jujube-like hierarchical TiO2 microspheres (HTMs) were synthesized by an alkali-corrosion process of titanium phosphate (Ti2O3(H2PO4)2 · 2H2O) microspheres. The hierarchical titanium phosphate microsphere (HTPM) intermediates consisting of nanoflakes with a thickness of 20 nm were firstly prepared by a facile hydrothermal method. After reacting with diluted NaOH at low temperature and atmospheric pressure, followed by subsequent acid washing and a calcination process, the HTPM intermediates were transformed to TiO2 with the microsphere morphology well retained, while the nanoflakes became porous, and some new nanowires were formed between the nanoflakes. Finally, HTMs consisting of porous nanoflakes and nanowires were obtained. The possible growth mechanisms of HTPMs and HTMs are discussed. The HTMs demonstrate high specific surface area and excellent light-scattering ability. The performance of the dye sensitized solar cells (DSSCs) of the HTMs synthesized under different conditions is studied, and a total conversion efficiency of up to 8.93% was obtained. The improved DSSC performance was attributed to the enhanced dye loading, light-scattering, and charge transporting ability of the HTMs with a unique hierarchical nanostructure.
Nanomechanical Behavior of High Gas Barrier Multilayer Thin Films.
Humood, Mohammad; Chowdhury, Shahla; Song, Yixuan; Tzeng, Ping; Grunlan, Jaime C; Polycarpou, Andreas A
2016-05-04
Nanoindentation and nanoscratch experiments were performed on thin multilayer films manufactured using the layer-by-layer (LbL) assembly technique. These films are known to exhibit high gas barrier, but little is known about their durability, which is an important feature for various packaging applications (e.g., food and electronics). Films were prepared from bilayer and quadlayer sequences, with varying thickness and composition. In an effort to evaluate multilayer thin film surface and mechanical properties, and their resistance to failure and wear, a comprehensive range of experiments were conducted: low and high load indentation, low and high load scratch. Some of the thin films were found to have exceptional mechanical behavior and exhibit excellent scratch resistance. Specifically, nanobrick wall structures, comprising montmorillonite (MMT) clay and polyethylenimine (PEI) bilayers, are the most durable coatings. PEI/MMT films exhibit high hardness, large elastic modulus, high elastic recovery, low friction, low scratch depth, and a smooth surface. When combined with the low oxygen permeability and high optical transmission of these thin films, these excellent mechanical properties make them good candidates for hard coating surface-sensitive substrates, where polymers are required to sustain long-term surface aesthetics and quality.
Xiao, Jiajia; Li, Po; Wen, Xiaogang
2018-04-27
Novel jujube-like hierarchical TiO 2 microspheres (HTMs) were synthesized by an alkali-corrosion process of titanium phosphate (Ti 2 O 3 (H 2 PO 4 ) 2 · 2H 2 O) microspheres. The hierarchical titanium phosphate microsphere (HTPM) intermediates consisting of nanoflakes with a thickness of 20 nm were firstly prepared by a facile hydrothermal method. After reacting with diluted NaOH at low temperature and atmospheric pressure, followed by subsequent acid washing and a calcination process, the HTPM intermediates were transformed to TiO 2 with the microsphere morphology well retained, while the nanoflakes became porous, and some new nanowires were formed between the nanoflakes. Finally, HTMs consisting of porous nanoflakes and nanowires were obtained. The possible growth mechanisms of HTPMs and HTMs are discussed. The HTMs demonstrate high specific surface area and excellent light-scattering ability. The performance of the dye sensitized solar cells (DSSCs) of the HTMs synthesized under different conditions is studied, and a total conversion efficiency of up to 8.93% was obtained. The improved DSSC performance was attributed to the enhanced dye loading, light-scattering, and charge transporting ability of the HTMs with a unique hierarchical nanostructure.
Beltrame, Anna; Guerriero, Massimo; Angheben, Andrea; Gobbi, Federico; Requena-Mendez, Ana; Zammarchi, Lorenzo; Formenti, Fabio; Perandin, Francesca; Bisoffi, Zeno
2017-01-01
Background Schistosomiasis is a neglected infection affecting millions of people, mostly living in sub-Saharan Africa. Morbidity and mortality due to chronic infection are relevant, although schistosomiasis is often clinically silent. Different diagnostic tests have been implemented in order to improve screening and diagnosis, that traditionally rely on parasitological tests with low sensitivity. Aim of this study was to evaluate the accuracy of different tests for the screening of schistosomiasis in African migrants, in a non endemic setting. Methodology/Principal findings A retrospective study was conducted on 373 patients screened at the Centre for Tropical Diseases (CTD) in Negrar, Verona, Italy. Biological samples were tested with: stool/urine microscopy, Circulating Cathodic Antigen (CCA) dipstick test, ELISA, Western blot, immune-chromatographic test (ICT). Test accuracy and predictive values of the immunological tests were assessed primarily on the basis of the results of microscopy (primary reference standard): ICT and WB resulted the test with highest sensitivity (94% and 92%, respectively), with a high NPV (98%). CCA showed the highest specificity (93%), but low sensitivity (48%). The analysis was conducted also using a composite reference standard, CRS (patients classified as infected in case of positive microscopy and/or at least 2 concordant positive immunological tests) and Latent Class Analysis (LCA). The latter two models demonstrated excellent agreement (Cohen’s kappa: 0.92) for the classification of the results. In fact, they both confirmed ICT as the test with the highest sensitivity (96%) and NPV (97%), moreover PPV was reasonably good (78% and 72% according to CRS and LCA, respectively). ELISA resulted the most specific immunological test (over 99%). The ICT appears to be a suitable screening test, even when used alone. Conclusions The rapid test ICT was the most sensitive test, with the potential of being used as a single screening test for African migrants. PMID:28582412
Sterilization of endoscopic instruments.
Sabnis, Ravindra B; Bhattu, Amit; Vijaykumar, Mohankumar
2014-03-01
Sterilization of endoscopic instruments is an important but often ignored topic. The purpose of this article is to review the current literature on the sterilization of endoscopic instruments and elaborate on the appropriate sterilization practices. Autoclaving is an economic and excellent method of sterilizing the instruments that are not heat sensitive. Heat sensitive instruments may get damaged with hot sterilization methods. Several new endoscopic instruments such as flexible ureteroscopes, chip on tip endoscopes, are added in urologists armamentarium. Many of these instruments are heat sensitive and hence alternative efficacious methods of sterilization are necessary. Although ethylene oxide and hydrogen peroxide are excellent methods of sterilization, they have some drawbacks. Gamma irradiation is mainly for disposable items. Various chemical agents are widely used even though they achieve high-level disinfection rather than sterilization. This article reviews various methods of endoscopic instrument sterilization with their advantages and drawbacks. If appropriate sterilization methods are adopted, then it not only will protect patients from procedure-related infections but prevent hypersensitive allergic reactions. It will also protect instruments from damage and increase its longevity.
NASA Astrophysics Data System (ADS)
Sharma, Alfa; Kumar, Yogendra; Shirage, Parasharam M.
2018-04-01
The chemi-resistive humidity sensing behaviour of as prepared and annealed ZnSnO3 nanoparticles synthesized using a wet chemical synthesis method was investigated. The effect of stirring temperature over the evolution of varied nanomorphology of zinc stannate is in accordance to Ostwald's ripening law. At room temperature, an excellent humidity sensitivity of ˜800% and response/recovery time of 70s./102s. is observed for ZnSnO3 sample within 08-97% relative humidity range. The experimental data observed over the entire range of RH values well fitted with the Freundlich adsorption isotherm model, and revealing two distinct water adsorption regimes. The excellent humidity sensitivity observed in the nanostructures is attributed to Grotthuss mechanism considering the availability and distribution of available adsorption sites. This present result proposes utilization of low cost synthesis technique of ZnSnO3 holds the promising capabilities as potential candidate for the fabrication of next generation humidity sensors.
NASA Astrophysics Data System (ADS)
Hasna, Kudilatt; Lakshmi, Kiran; Ezhuthachan Jayaraj, Madambi Kunjukuttan; Kumar, Kumaran Rajeev; Matham, Murukeshan Vadakke
2016-04-01
Surface-enhanced Raman spectroscopy (SERS) has emerged as one of the thrust research areas that could find potential applications in bio and chemical sensing. We developed colloidal SERS active substrate with excellent sensitivity and high reproducibility using silver nanocube (AgNC) synthesized via the solvothermal method. Finite-difference time-domain simulation was carried out in detail to visualize dipole generation in the nanocube during localized surface plasmon resonance and to locate the respective hot spots in AgNC responsible for the huge Raman enhancement. The prediction is verified by the SERS analysis of the synthesized nanocubes using Rhodamine 6G molecule. An excellent sensitivity with a detection limit of 10-17 M and a very high enhancement factor of 1.2×108 confirms the "hot spots" in the nanocube. SERS activity is also carried out for crystal violet and for food adulterant Sudan I molecule. Finally, label-free DNA detection is performed to demonstrate the versatility of SERS as a potential biosensor.
Shape control of Co3O4 micro-structures for high-performance gas sensor
NASA Astrophysics Data System (ADS)
Zhou, Qu; Zeng, Wen
2018-01-01
Recently, spinel cobalt oxide (Co3O4) structure has been widely investigated due to its excellent sensitivity towards various noxious gases and good response/recovery speed at low concentration. In this work, we designed and synthesized two kinds of different Co3O4 micro-structure (cube and octahedron) with a similar size. After fabricating them into gas sensors, we found that the crystal plane structure of Co3O4 has an important effect on its gas sensing performance. Furthermore, the {111} planes of Co3O4may be more sensitive than {100} planes to various testing gases. Co3O4 octahedrons micro-structure exhibits an excellent sensitivity (about 12.6), good response/recovery speed and cycling stability (no decline even after 2 days) under 50 ppm ethanol gases at working temperature of 200 °C. As such, thisCo3O4 octahedrons micro-structure is a promising candidate for a high-performance gas sensing material.
Dasary, Samuel S.R.; Zones, Yolanda K.; Barnes, Sandra L.; Ray, P. C.; Singh, Anant K.
2015-01-01
Alizarin functionalized on plasmonic gold nanoparticle displays strong surface enhanced Raman scattering from the various Raman modes of Alizarin, which can be exploited in multiple ways for heavy metal sensing purposes. The present article reports a surface enhanced Raman spectroscopy (SERS) probe for trace level Cadmium in water samples. Alizarin, a highly Raman active dye was functionalized on plasmonic gold surface as a Raman reporter, and then 3-mercaptopropionic acid, 2,6-Pyridinedicarboxylic acid at pH 8.5 was immobilized on the surface of the nanoparticle for the selective coordination of the Cd (II). Upon addition of Cadmium, gold nanoparticle provide an excellent hotspot for Alizarin dye and Raman signal enhancement. This plasmonic SERS assay provided an excellent sensitivity for Cadmium detection from the drinking water samples. We achieved as low as 10 ppt sensitivity from various drinking water sources against other Alkali and heavy metal ions. The developed SERS probe is quite simple and rapid with excellent repeatability and has great potential for prototype scale up for field application. PMID:26770012
Lin, Songyue; Feng, Wendou; Miao, Xiaofei; Zhang, Xiangxin; Chen, Sujing; Chen, Yuanqiang; Wang, Wei; Zhang, Yining
2018-07-01
Flexible and implantable glucose biosensors are emerging technologies for continuous monitoring of blood-glucose of diabetes. Developing a flexible conductive substrates with high active surface area is critical for advancing the technology. Here, we successfully fabricate a flexible and highly sensitive nonenzymatic glucose by using DVD-laser scribed graphene (LSG) as a flexible conductively substrate. Copper nanoparticles (Cu-NPs) are electrodeposited as the catalyst. The LSG/Cu-NPs sensor demonstrates excellent catalytic activity toward glucose oxidation and exhibits a linear glucose detection range from 1 μM to 4.54 mM with high sensitivity (1.518 mA mM -1 cm -2 ) and low limit of detection (0.35 μM). Moreover, the LSG/Cu-NPs sensor shows excellent reproducibility and long-term stability. It is also highly selective toward glucose oxidation under the presence of various interfering species. Excellent flexing stability is also demonstrated by the LSG/Cu-NPs sensor, which is capable of maintaining 83.9% of its initial current after being bent against a 4-mm diameter rod for 180 times. The LSG/Cu-NPs sensor shows great potential for practical application as a nonenzymatic glucose biosensor. Meanwhile, the LSG conductive substrate provides a platform for the developing next-generation flexible and potentially implantable bioelectronics and biosensors. Copyright © 2018 Elsevier B.V. All rights reserved.
The Roads of "Excellence" in Central and Eastern Europe
ERIC Educational Resources Information Center
Antonowicz, Dominik; Kohoutek, Jan; Pinheiro, Rómulo; Hladchenko, Myroslava
2017-01-01
The aim of the article is to explore the impact of excellence as a powerful policy idea in the context of recent and contemporary developments in three selected Central and Eastern European countries, namely, the Czech Republic, Poland and Ukraine. More specifically, we explore how excellence as a "global script" was translated by policy…
ERIC Educational Resources Information Center
Morris, Marian; Rutt, Simon
2006-01-01
Aimhigher: Excellence Challenge (initially known as Excellence Challenge) was specifically established by the Department for Education and Skills (DfES) in 2001, with the aim of increasing the number of young people from disadvantaged backgrounds who had the qualifications and aspirations necessary to enter higher education. The analysis conducted…
Excel in the Accounting Curriculum: Perceptions from Accounting Professors
ERIC Educational Resources Information Center
Ramachandran Rackliffe, Usha; Ragland, Linda
2016-01-01
Public accounting firms emphasize the importance of accounting graduates being proficient in Excel. Since many accounting graduates often aspire to work in public accounting, a question arises as to whether there should be an emphasis on Excel in accounting education. The purpose of this paper is to specifically look at this issue by examining…
The potential of multiparametric MRI of the breast
Pinker, Katja; Helbich, Thomas H
2017-01-01
MRI is an essential tool in breast imaging, with multiple established indications. Dynamic contrast-enhanced MRI (DCE-MRI) is the backbone of any breast MRI protocol and has an excellent sensitivity and good specificity for breast cancer diagnosis. DCE-MRI provides high-resolution morphological information, as well as some functional information about neoangiogenesis as a tumour-specific feature. To overcome limitations in specificity, several other functional MRI parameters have been investigated and the application of these combined parameters is defined as multiparametric MRI (mpMRI) of the breast. MpMRI of the breast can be performed at different field strengths (1.5–7 T) and includes both established (diffusion-weighted imaging, MR spectroscopic imaging) and novel MRI parameters (sodium imaging, chemical exchange saturation transfer imaging, blood oxygen level-dependent MRI), as well as hybrid imaging with positron emission tomography (PET)/MRI and different radiotracers. Available data suggest that multiparametric imaging using different functional MRI and PET parameters can provide detailed information about the underlying oncogenic processes of cancer development and progression and can provide additional specificity. This article will review the current and emerging functional parameters for mpMRI of the breast for improved diagnostic accuracy in breast cancer. PMID:27805423
Lee, Donghwa; Lee, Hyungjin; Jeong, Youngjun; Ahn, Yumi; Nam, Geonik; Lee, Youngu
2016-11-01
Highly sensitive, transparent, and durable pressure sensors are fabricated using sea-urchin-shaped metal nanoparticles and insulating polyurethane elastomer. The pressure sensors exhibit outstanding sensitivity (2.46 kPa -1 ), superior optical transmittance (84.8% at 550 nm), fast response/relaxation time (30 ms), and excellent operational durability. In addition, the pressure sensors successfully detect minute movements of human muscles. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Highly sensitive graphene biosensor by monomolecular self-assembly of receptors on graphene surface
NASA Astrophysics Data System (ADS)
Kim, Ji Eun; No, Young Hyun; Kim, Joo Nam; Shin, Yong Seon; Kang, Won Tae; Kim, Young Rae; Kim, Kun Nyun; Kim, Yong Ho; Yu, Woo Jong
2017-05-01
Graphene has attracted a great deal of interest for applications in bio-sensing devices because of its ultra-thin structure, which enables strong electrostatic coupling with target molecules, and its excellent electrical mobility promising for ultra-fast sensing speeds. However, thickly stacked receptors on the graphene's surface interrupts electrostatic coupling between graphene and charged biomolecules, which can reduce the sensitivity of graphene biosensors. Here, we report a highly sensitive graphene biosensor by the monomolecular self-assembly of designed peptide protein receptors. The graphene channel was non-covalently functionalized using peptide protein receptors via the π-π interaction along the graphene's Bravais lattice, allowing ultra-thin monomolecular self-assembly through the graphene lattice. In thickness dependent characterization, a graphene sensor with a monomolecular receptor (thickness less than 3 nm) showed five times higher sensitivity and three times higher voltage shifts than graphene sensors with thick receptor stacks (thicknesses greater than 20 nm), which is attributed to excellent gate coupling between graphene and streptavidin via an ultrathin receptor insulator. In addition to having a fast-inherent response time (less than 0.6 s) based on fast binding speed between biotin and streptavidin, our graphene biosensor is a promising platform for highly sensitive real-time monitoring of biomolecules with high spatiotemporal resolution.
Stretchable Platinum Network-Based Transparent Electrodes for Highly Sensitive Wearable Electronics.
Wang, Yuting; Cheng, Jing; Xing, Yan; Shahid, Muhammad; Nishijima, Hiroki; Pan, Wei
2017-07-01
A platinum network-based transparent electrode has been fabricated by electrospinning. The unique nanobelt structured electrode demonstrates low sheet resistance (about 16 Ω sq -1 ) and high transparency of 80% and excellent flexibility. One of the most interesting demonstrations of this Pt nanobelt electrode is its excellent reversibly resilient characteristic. The electric conductivity of the flexible Pt electrode can recover to its initial value after 160% extending and this performance is repeatable and stable. The good linear relationship between the resistance and strain of the unique structured Pt electrode makes it possible to assemble a wearable high sensitive strain sensor. Present reported Pt nanobelt electrode also reveals potential applications in electrode for flexible fuel cells and highly transparent ultraviolet (UV) sensors. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Selective Detection of Neurotransmitters by Fluorescence and Chemiluminescence Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ziqiang Wang; Edward S. Yeung
In recent years, luminescence imaging has been widely employed in neurochemical analysis. It has a number of advantages for the study of neuronal and other biological cells: (1) a particular molecular species or cellular constituent can be selectively visualized in the presence of a large excess of other species in a heterogeneous environment; (2) low concentration detection limits can be achieved because of the inherent sensitivity associated with fluorescence and chemiluminescence; (3) low excitation intensities can be used so that long-term observation can be realized while the viability of the specimen is preserved; and (4) excellent spatial resolution can bemore » obtained with the light microscope so subcellular compartments can be identified. With good sensitivity, temporal and spatial resolution, the flux of ions and molecules and the distribution and dynamics of intracellular species can be measured in real time with specific luminescence probes, substrates, or with native fluorescence. A noninvasive detection scheme based on glutamate dehydrogenase (GDH) enzymatic assay combined with microscopy was developed to measure the glutamate release in cultured cells from the central nervous system (CNS). The enzyme reaction is very specific and sensitive. The detection limit with CCD imaging is down to {micro}M levels of glutamate with reasonable response time. They also found that chemiluminescence associated with the ATP-dependent reaction between luciferase and luciferin can be used to image ATP at levels down to 10 nM in the millisecond time scale. Similar imaging experiments should be feasible in a broad spectrum of biological systems.« less
NASA Astrophysics Data System (ADS)
Zhan, Fangfang; Zhou, Xiaoming
2012-12-01
Rotaviruses are double-stranded RNA viruses belonging to the family of enteric pathogens. It is a major cause of diarrhoeal disease in infants and young children worldwide. Consequently, rapid and accurate detection of rotaviruses is of great importance in controlling and preventing food- and waterborne diseases and outbreaks. Reverse transcription-polymerase chain reaction (RT-PCR) is a reliable method that possesses high specificity and sensitivity. It has been widely used to detection of viruses. Electrochemiluminescence (ECL) can be considered as an important and powerful tool in analytical and clinical application with high sensitivity, excellent specificity, and low cost. Here we have developed a method for the detection of rotavirus by combining in situ magnetic beads (MBs) based RT-PCR with ECL. RT of rotavirus RNA was carried out in a traditional way and the resulting cDNA was directly amplified on MBs. Forward primers were covalently bounded to MBs and reverse primers were labeled with tris-(2, 2'-bipyridyl) ruthenium (TBR). During the PCR cycling, the TBR labeled products were directly loaded and enriched on the surface of MBs. Then the MBs-TBR complexes could be analyzed by a magnetic ECL platform without any post-modification or post-incubation which avoid some laborious manual operations and achieve rapid yet sensitive detection. In this study, rotavirus from fecal specimens was successfully detected within 2 h, and the limit of detection was estimated to be 104copies/μL. This novel in situ MBs based RT-PCR with ECL detection method can be used for pathogen detection in food safety field and clinical diagnosis.
Fan, Dawei; Bao, Chunzhu; Khan, Malik Saddam; Wang, Chuanlei; Zhang, Yong; Liu, Qinze; Zhang, Xian; Wei, Qin
2018-05-30
A novel label-free photoelectrochemical (PEC) sensor based on graphene quantum dots doped with nitrogen and sulfur (N,S-GQDs) and CdS co-sensitized hierarchical Zn 2 SnO 4 cube was fabricated to detect cardiac troponin I (cTnI). The unique hierarchical Zn 2 SnO 4 cube was synthesized successfully by the solvothermal method, which has a large specific surface to load functional materials. N,S-GQDs nanoparticles were assembled to the surface of cubic Zn 2 SnO 4 coated ITO electrode, which efficiently accelerated the electronic transition and improved photo-to-current conversion efficiency. Then, CdS nanoparticles further were modified by in-situ growth method to form Zn 2 SnO 4 /N,S-GQDs/CdS composite with prominent photocurrent, which was 30 times that of the Zn 2 SnO 4 cube alone. In this work, the specific immune recognition between cTnI antigens and cTnI antibodies (anti-cTnI) reduced the intensity of the photoelectric signal. And the intensity decreased linearly with the logarithm of cTnI concentration range from 0.001 ng/mL to 50 ng/mL with a detection limit of 0.3 pg/mL. With high sensitivity, excellent selectivity, good stability and reproducibility, the fabricated PEC sensor showed promising applications in the sensor, clinical diagnosis of myocardial infarction and PEC analysis. Copyright © 2018 Elsevier B.V. All rights reserved.
Zhang, Lijun; Wang, Guiheng; Wu, Di; Xiong, Can; Zheng, Lei; Ding, Yunsheng; Lu, Hongbo; Zhang, Guobing; Qiu, Longzhen
2018-02-15
In this study, an organic electrochemical transistor sensor (OECT) with a molecularly imprinted polymer (MIP)-modified gate electrode was prepared for the detection of ascorbic acid (AA). The combination of the amplification function of an OECT and the selective specificity of MIPs afforded a highly sensitive, selective OECT sensor. Cyclic voltammetry and electrochemical impedance spectroscopy measurements were carried out to monitor the stepwise fabrication of the modified electrodes and the adsorption capacity of the MIP/Au electrodes. Atomic force microscopy was employed for examining the surface morphology of the electrodes. Important detection parameters, pH and detection temperature were optimized. With the change in the relative concentration of AA from 1μM to 100μM, the MIP-OECT sensor exhibited a low detection limit of 10nM (S/N > 3) and a sensitivity of 75.3μA channel current change per decade under optimal conditions. In addition, the MIP-OECT sensor exhibited excellent specific recognition ability to AA, which prevented the interference from other structurally similar compounds (e.g., aspartic acid, glucose, uric acid, glycine, glutathione, H 2 O 2 ), and common metal ions (K + , Na + , Ca 2+ , Mg 2+ , and Fe 2+ ). In addition, a series of vitamin C beverages were analyzed to demonstrate the feasibility of the MIP-OECT sensor. Using the proposed principle, several other sensors with improved performance can be constructed via the modification of organic electrochemical transistors with appropriate MIP films. Copyright © 2017 Elsevier B.V. All rights reserved.
Chen, Yajing; Xiong, Zhichao; Zhang, Lingyi; Zhao, Jiaying; Zhang, Quanqing; Peng, Li; Zhang, Weibing; Ye, Mingliang; Zou, Hanfa
2015-02-21
Highly selective and efficient capture of glycosylated proteins and peptides from complex biological samples is of profound significance for the discovery of disease biomarkers in biological systems. Recently, hydrophilic interaction liquid chromatography (HILIC)-based functional materials have been extensively utilized for glycopeptide enrichment. However, the low amount of immobilized hydrophilic groups on the affinity material has limited its specificity, detection sensitivity and binding capacity in the capture of glycopeptides. Herein, a novel affinity material was synthesized to improve the binding capacity and detection sensitivity for glycopeptides by coating a poly(2-(methacryloyloxy)ethyl)-dimethyl-(3-sulfopropyl) ammonium hydroxide (PMSA) shell onto Fe3O4@SiO2 nanoparticles, taking advantage of reflux-precipitation polymerization for the first time (denoted as Fe3O4@SiO2@PMSA). The thick polymer shell endows the nanoparticles with excellent hydrophilic property and several functional groups on the polymer chains. The resulting Fe3O4@SiO2@PMSA demonstrated an outstanding ability for glycopeptide enrichment with high selectivity, extremely high detection sensitivity (0.1 fmol), large binding capacity (100 mg g(-1)), high enrichment recovery (above 73.6%) and rapid magnetic separation. Furthermore, in the analysis of real complicated biological samples, 905 unique N-glycosylation sites from 458 N-glycosylated proteins were reliably identified in three replicate analyses of a 65 μg protein sample extracted from mouse liver, showing the great potential of Fe3O4@SiO2@PMSA in the detection and identification of low-abundance N-linked glycopeptides in biological samples.
Chen, Wei; Rosser, Ethan W.; Zhang, Di; ...
2015-05-11
Hydrogen polysulfides (H 2S n, n>1) have been recently suggested to be the actual signalling molecules that involved in sulfur-related redox biology. However the exact mechanisms of H 2S n are still poorly understood and a major hurdle in this field is the lack of reliable and convenient methods for H 2S n detection. In this work we report a unique ring-opening reaction of N-sulfonylaziridine by Na 2S 2 under mild conditions. Based on this reaction a novel H 2S n-specific fluorescent probe (AP) was developed. The probe showed high sensitivity and selectivity for H 2S n. Notably, the fluorescentmore » turn-on product, i.e. compound 1, exhibited excellent two-photon photophysical properties and a large Stokes shift. Moreover, the high solid state luminescent efficiency of compound 1 makes it a potential candidate for organic emitters and solid-state lighting devices.« less
NASA Astrophysics Data System (ADS)
Wang, Ming-Qi; Ren, Gui-Ying; Zhao, Shuang; Lian, Guang-Chang; Chen, Ting-Ting; Ci, Yang; Li, Hong-Yao
2018-06-01
G-quadruplex DNAs are highly prevalent in the human genome and involved in many important biological processes. However, many aspects of their biological mechanism and significance still need to be elucidated. Therefore, the development of fluorescent probes for G-quadruplex detection is important for the basic research. We report here on the development of small molecular dyes designed on the basis of carbazole scaffold by introducing styrene-like substituents at its 9-position, for the purpose of G-quadruplex recognition. Results revealed that the side group on the carbazole scaffold was very important for their ability to selectively recognize G-quadruplex DNA structures. 1a with the pyridine side group displayed excellent fluorescence signal turn-on property for the specific discrimination of G-quadruplex DNAs against other nucleic acids. The characteristics of 1a were further investigated with UV-vis spectrophotometry, fluorescence, circular dichroism, FID assay and molecular docking to validate the selectivity, sensitivity and detailed binding mode toward G-quadruplex DNAs.
From Bits and Pieces to Whole Phage to Nanomachines: Pathogen Detection Using Bacteriophages.
Anany, H; Chou, Y; Cucic, S; Derda, R; Evoy, S; Griffiths, M W
2017-02-28
The innate specificity of bacteriophages toward their hosts makes them excellent candidates for the development of detection assays. They can be used in many ways to detect pathogens, and each has its own advantages and disadvantages. Whole bacteriophages can carry reporter genes to alter the phenotype of the target. Bacteriophages can act as staining agents or the progeny of the infection process can be detected, which further increases the sensitivity of the detection assay. Compared with whole-phage particles, use of phage components as probes offers other advantages: for example, smaller probe size to enhance binding activity, phage structures that can be engineered for better affinity, as well as specificity, binding properties, and robustness. When no natural binding with the target exists, phages can be used as vehicles to identify new protein-ligand interactions necessary for diagnostics. This review comprehensively summarizes many uses of phages as detection tools and points the way toward how phage-based technologies may be improved.
Nithya, Ravichantar; Ahmed, Siti Aminah; Hoe, Chee-Hock; Gopinath, Subash C B; Citartan, Marimuthu; Chinni, Suresh V; Lee, Li Pin; Rozhdestvensky, Timofey S; Tang, Thean-Hock
2015-01-01
Salmonellosis, a communicable disease caused by members of the Salmonella species, transmitted to humans through contaminated food or water. It is of paramount importance, to generate accurate detection methods for discriminating the various Salmonella species that cause severe infection in humans, including S. Typhi and S. Paratyphi A. Here, we formulated a strategy of detection and differentiation of salmonellosis by a multiplex polymerase chain reaction assay using S. Typhi non-protein coding RNA (sRNA) genes. With the designed sequences that specifically detect sRNA genes from S. Typhi and S. Paratyphi A, a detection limit of up to 10 pg was achieved. Moreover, in a stool-seeding experiment with S. Typhi and S. Paratyphi A, we have attained a respective detection limit of 15 and 1.5 CFU/mL. The designed strategy using sRNA genes shown here is comparatively sensitive and specific, suitable for clinical diagnosis and disease surveillance, and sRNAs represent an excellent molecular target for infectious disease.
Jäckel, S; Eiden, M; Balkema-Buschmann, A; Ziller, M; van Vuren, P Jansen; Paweska, J T; Groschup, M H
2013-10-01
Rift Valley fever virus (RVFV) is an emerging zoonotic pathogen that causes high morbidity and mortality in humans and livestock. In this paper, we describe the cloning, expression and purification of RVFV glycoprotein Gn and its application as a diagnostic antigen in an indirect ELISA for the specific detection of RVF IgG antibodies in sheep and goats. The performance of this Gn based ELISA is validated using a panel of almost 2000 field samples from sheep and goats from Mozambique, Senegal, Uganda and Yemen. All serum samples were also tested by virus neutralization test (VNT), the gold standard method for RVFV serological testing. Compared to the VNT results the Gn based ELISA proved to have an excellent sensitivity (94.56%) and specificity (95.57%). Apart from establishing this new diagnostic assay, these results also demonstrate a close correlation between the presence of RVFV Gn and neutralizing antibodies. Copyright © 2013 Elsevier Ltd. All rights reserved.
Innovative Ge Quantum Dot Functional Sensing/Metrology Devices
2015-05-20
sensitive to charge number and local temperature with unprecedented precision. Accordingly we have made progresses in the innovative functionalities...sensors feature excellent sensitivity on charge number, local temperature, and photoresponsivity in the visible to near IR wavelength. “Designer” Ge...Detailed knowledge and understanding of how the QDs are created, and especially their interactions with their local environments are therefore crucial to
New agents with antimycobacterial activity.
Marco-Contelles, José; Gómez-Sánchez, Elena
2005-11-01
In this paper, we report that a series of structurally simple a-halogenoacetamides show potent and excellent antimycobacterial activities against drug-sensitive Mycobacterium tuberculosis H(37)Rv and drug-resistant M. avium.
Abou-Taleb, Doaa A E; Ibrahim, Ahmed K; Youssef, Eman M K; Moubasher, Alaa E A
2017-02-01
The new modified Melasma Area and Severity Index (mMASI) score, the recently used outcome measure for melasma, has not been tested to determine its sensitivity to change in melasma. To determine the reliability, validity, and sensitivity to change overtime of the mMASI score in assessment of the severity of melasma. Pearson correlation, Cronbach alpha, and intraclass correlation coefficient were calculated to assess the reliability of the mMASI score. Validity of the mMASI scale was carried out using Spearman correlation between mMASI total score (before and after treatment), clinical data, and patient's responses. The mMASI score showed excellent reliability and good validity for assessment of the severity of melasma. The authors also determined that the mMASI score demonstrated sensitivity to change over time. An excellent degree of agreement between the mMSAI and MASI scores was revealed. The mMASI score is reliable, valid, and responsive to change in the assessment of severity of melasma. Moreover, the mMASI score was found to be easier to learn and perform and simpler in calculation compared with the MASI score. Overall, the mMASI score can effectively replace the MASI score.
Liquid xenon calorimeter for MEG II experiment with VUV-sensitive MPPCs
NASA Astrophysics Data System (ADS)
Ogawa, Shinji; MEG II Collaboration
2017-02-01
The MEG II experiment is an upgrade of the MEG experiment to search for the charged lepton flavor violating decay of muon, μ+ →e+ γ . The MEG II experiment is expected to reach a branching ratio sensitivity of 4 ×10-14 , which is one order of magnitude better than the sensitivity of the current MEG experiment. The performance of the liquid xenon (LXe) γ-ray detector will be greatly improved with a highly granular scintillation readout realized by replacing 216 photomultiplier tubes (PMTs) on the γ-ray entrance face with 4092 Multi-Pixel Photon Counters (MPPCs). For this purpose, we have developed a new type of MPPC which is sensitive to the LXe scintillation light in vacuum ultraviolet (VUV) range, in collaboration with Hamamatsu Photonics K.K. We have measured the performance of the MPPC in LXe, and an excellent performance has been confirmed including high photon detection efficiency (> 15 %) for LXe scintillation light. An excellent performance of the LXe detector has been confirmed by Monte Carlo simulations based on the measured properties of the MPPC. The construction of the detector is in progress, aiming to start physics data taking in 2017.
TmDOTA -: A Sensitive Probe for MR Thermometry in Vivo
NASA Astrophysics Data System (ADS)
Zuo, Chun S.; Mahmood, Ashfaq; Sherry, A. Dean
2001-07-01
The lanthanide complex, thulium 1,4,7,10-tetraazacyclodo- decane-1,4,7,10-tetraacetic acid (TmDOTA-), has been investigated as an agent for MR thermometry in vivo. The chemical shifts of the TmDOTA- protons were highly sensitive to temperature at a clinically relevant field strength, yet insensitive to pH and the presence of Ca2+. Given the excellent stability of lanthanide-DOTA complexes and high thermal sensitivity, TmDOTA- is expected to be a good candidate for MR thermometry in vivo.
Detection of Bacillus spores using PCR and FTA filters.
Lampel, Keith A; Dyer, Deanne; Kornegay, Leroy; Orlandi, Palmer A
2004-05-01
Emphasis has been placed on developing and implementing rapid detection systems for microbial pathogens. We have explored the utility of expanding FTA filter technology for the preparation of template DNA for PCR from bacterial spores. Isolated spores from several Bacillus spp., B. subtilis, B. cereus, and B. megaterium, were applied to FTA filters, and specific DNA products were amplified by PCR. Spore preparations were examined microscopically to ensure that the presence of vegetative cells, if any, did not yield misleading results. PCR primers SRM86 and SRM87 targeted a conserved region of bacterial rRNA genes, whereas primers Bsub5F and Bsub3R amplified a product from a conserved sequence of the B. subtilis rRNA gene. With the use of the latter set of primers for nested PCR, the sensitivity of the PCR-based assay was increased. Overall, 53 spores could be detected after the first round of PCR, and the sensitivity was increased to five spores by nested PCR. FTA filters are an excellent platform to remove PCR inhibitors and have universal applications for environmental, clinical, and food samples.
Highly Effective Serodiagnosis for Chagas' Disease ▿
Hernández, Pilar; Heimann, Michael; Riera, Cristina; Solano, Marco; Santalla, José; Luquetti, Alejandro O.; Beck, Ewald
2010-01-01
Many proteins of Trypanosoma cruzi, the causative agent of Chagas' disease, contain characteristic arrays of highly repetitive immunogenic amino acid motifs. Diagnostic tests using these motifs in monomeric or dimeric form have proven to provide markedly improved specificity compared to conventional tests based on crude parasite extracts. However, in many cases the available tests still suffer from limited sensitivity. In this study we produced stable synthetic genes with maximal codon variability for the four diagnostic antigens, B13, CRA, TcD, and TcE, each containing between three and nine identical amino acid repeats. These genes were combined by linker sequences encoding short proline-rich peptides, giving rise to a 24-kDa fusion protein which was used as a novel diagnostic antigen in an enzyme-linked immunosorbent assay setup. Validation of the assay with a large number of well-characterized patient sera from Bolivia and Brazil revealed excellent diagnostic performance. The high sensitivity of the new test may allow future studies to use blood collected by finger prick and dried on filter paper, thus dramatically reducing the costs and effort for the detection of T. cruzi infection. PMID:20668136
Genome-scale measurement of off-target activity using Cas9 toxicity in high-throughput screens.
Morgens, David W; Wainberg, Michael; Boyle, Evan A; Ursu, Oana; Araya, Carlos L; Tsui, C Kimberly; Haney, Michael S; Hess, Gaelen T; Han, Kyuho; Jeng, Edwin E; Li, Amy; Snyder, Michael P; Greenleaf, William J; Kundaje, Anshul; Bassik, Michael C
2017-05-05
CRISPR-Cas9 screens are powerful tools for high-throughput interrogation of genome function, but can be confounded by nuclease-induced toxicity at both on- and off-target sites, likely due to DNA damage. Here, to test potential solutions to this issue, we design and analyse a CRISPR-Cas9 library with 10 variable-length guides per gene and thousands of negative controls targeting non-functional, non-genic regions (termed safe-targeting guides), in addition to non-targeting controls. We find this library has excellent performance in identifying genes affecting growth and sensitivity to the ricin toxin. The safe-targeting guides allow for proper control of toxicity from on-target DNA damage. Using this toxicity as a proxy to measure off-target cutting, we demonstrate with tens of thousands of guides both the nucleotide position-dependent sensitivity to single mismatches and the reduction of off-target cutting using truncated guides. Our results demonstrate a simple strategy for high-throughput evaluation of target specificity and nuclease toxicity in Cas9 screens.
Genome-scale measurement of off-target activity using Cas9 toxicity in high-throughput screens
Morgens, David W.; Wainberg, Michael; Boyle, Evan A.; Ursu, Oana; Araya, Carlos L.; Tsui, C. Kimberly; Haney, Michael S.; Hess, Gaelen T.; Han, Kyuho; Jeng, Edwin E.; Li, Amy; Snyder, Michael P.; Greenleaf, William J.; Kundaje, Anshul; Bassik, Michael C.
2017-01-01
CRISPR-Cas9 screens are powerful tools for high-throughput interrogation of genome function, but can be confounded by nuclease-induced toxicity at both on- and off-target sites, likely due to DNA damage. Here, to test potential solutions to this issue, we design and analyse a CRISPR-Cas9 library with 10 variable-length guides per gene and thousands of negative controls targeting non-functional, non-genic regions (termed safe-targeting guides), in addition to non-targeting controls. We find this library has excellent performance in identifying genes affecting growth and sensitivity to the ricin toxin. The safe-targeting guides allow for proper control of toxicity from on-target DNA damage. Using this toxicity as a proxy to measure off-target cutting, we demonstrate with tens of thousands of guides both the nucleotide position-dependent sensitivity to single mismatches and the reduction of off-target cutting using truncated guides. Our results demonstrate a simple strategy for high-throughput evaluation of target specificity and nuclease toxicity in Cas9 screens. PMID:28474669
Meyler, Kenneth L; Meehan, Mary; Bennett, Desiree; Cunney, Robert; Cafferkey, Mary
2012-12-01
Since the introduction of the Haemophilus influenzae serotype b vaccine, invasive H. influenzae disease has become dominated by nontypeable (NT) strains. Several widely used molecular diagnostic methods have been shown to lack sensitivity or specificity in the detection of some of these strains. Novel real-time assays targeting the fucK, licA, and ompP2 genes were developed and evaluated. The fucK assay detected all strains of H. influenzae tested (n = 116) and had an analytical sensitivity of 10 genome copies/polymerase chain reaction (PCR). This assay detected both serotype b and NT H. influenzae in 12 previously positive specimens (culture and/or bexA PCR) and also detected H. influenzae in a further 5 of 883 culture-negative blood and cerebrospinal fluid (CSF) samples. The fucK assay has excellent potential as a diagnostic test for detection of typeable and nontypeable strains of invasive H. influenzae in clinical samples of blood and CSF. Copyright © 2012 Elsevier Inc. All rights reserved.
From optics to attention: visual perception in barn owls.
Harmening, Wolf M; Wagner, Hermann
2011-11-01
Barn owls are nocturnal predators which have evolved specific sensory and morphological adaptations to a life in dim light. Here, some of the most fundamental properties of spatial vision in barn owls are reviewed. The eye with its tubular shape is rigidly integrated in the skull so that eye movements are very much restricted. The eyes are oriented frontally, allowing for a large binocular overlap. Accommodation, but not pupil dilation, is coupled between the two eyes. The retina is rod dominated and lacks a visible fovea. Retinal ganglion cells form a marked region of highest density that extends to a horizontally oriented visual streak. Behavioural visual acuity and contrast sensitivity are poor, although the optical quality of the ocular media is excellent. A low f-number allows high image quality at low light levels. Vernier acuity was found to be a hyperacute percept. Owls have global stereopsis with hyperacute stereo acuity thresholds. Neurons of the visual Wulst are sensitive to binocular disparities. Orientation based saliency was demonstrated in a visual-search experiment, and higher cognitive abilities were shown when the owl's were able to use illusory contours for object discrimination.
Marydasan, Betsy; Madhuri, Bollapalli; Cherukommu, Shirisha; Jose, Jedy; Viji, Mambattakkara; Karunakaran, Suneesh C; Chandrashekar, Tavarekere K; Rao, Kunchala Sridhar; Rao, Ch Mohan; Ramaiah, Danaboyina
2018-06-14
With the objective of developing efficient sensitizers for therapeutic applications, we synthesized a water-soluble 5,10,15,20-tetrakis(3,4-dihydroxyphenyl)chlorin (TDC) and investigated its in vitro and in vivo biological efficacy, comparing it with the commercially available sensitizers. TDC showed high water solubility (6-fold) when compared with that of Foscan and exhibited excellent triplet-excited-state (84%) and singlet-oxygen (80%) yields. In vitro photobiological investigations in human-ovarian-cancer cell lines SKOV-3 showed high photocytotoxicity, negligible dark toxicity, rapid cellular uptake, and specific localization of TDC in neoplastic cells as assessed by flow-cytometric cell-cycle and propidium iodide staining analysis. The photodynamic effects of TDC include confirmed reactive-oxygen-species-induced mitochondrial damage leading to necrosis in SKOV-3 cell lines. The in vivo photodynamic activity in nude-mouse models demonstrated abrogation of tumor growth without any detectable pathology in the skin, liver, spleen, or kidney, thereby demonstrating TDC application as an efficient and safe photosensitizer.
Qiu, Huazhang; Wu, Namei; Zheng, Yanjie; Chen, Min; Weng, Shaohuang; Chen, Yuanzhong; Lin, Xinhua
2015-01-01
A robust and versatile signal-on fluorescence sensing strategy was developed to provide label-free detection of various target analytes. The strategy used SYBR Green I dye and graphene oxide as signal reporter and signal-to-background ratio enhancer, respectively. Multidrug resistance protein 1 (MDR1) gene and mercury ion (Hg2+) were selected as target analytes to investigate the generality of the method. The linear relationship and specificity of the detections showed that the sensitive and selective analyses of target analytes could be achieved by the proposed strategy with low detection limits of 0.5 and 2.2 nM for MDR1 gene and Hg2+, respectively. Moreover, the strategy was used to detect real samples. Analytical results of MDR1 gene in the serum indicated that the developed method is a promising alternative approach for real applications in complex systems. Furthermore, the recovery of the proposed method for Hg2+ detection was acceptable. Thus, the developed label-free signal-on fluorescence sensing strategy exhibited excellent universality, sensitivity, and handling convenience. PMID:25565810
Yang, Lin; Zhen, Shu Jun; Li, Yuan Fang; Huang, Cheng Zhi
2018-06-14
Graphene oxide (GO) exhibits distinctive Raman scattering features for its high frequency D (disordered) and tangential modes (G-band), which are characteristically sharp at 1580 cm-1 and 1350 cm-1, respectively, but are too weak for sensitive quantitation purposes. By depositing silver nanoparticles on the surface of GO in this contribution, both D and G bands of GO become enhanced. The enzyme label of this method controls the dissolution of silver nanoparticles on the surface of GO through hydrogen peroxide which is produced by the oxidation of the enzyme substrate. With the dissolution of the silver nanoparticles a greatly decreased SERS signal of GO was obtained. This strategy involves dual signal amplification of the enzyme and nanocomposites to improve the detection sensitivity. As a proof of concept, prostate specific antigen (PSA), a biomarker for prostate cancer, is successfully detected as a target by forming a sandwich structure in immunoassay. The SERS immunoassay possesses excellent analytical performance in the range 0.5 pg mL-1 to 500 pg mL-1 with a limit of detection of 0.23 pg mL-1, making the detection of PSA serum samples from prostate cancer patients satisfactory, demonstrating that the sensitive enzyme-assisted dissolved AgNPs SERS immunoassay of PSA has potential applications in clinical diagnosis.
Lectin functionalized ZnO nanoarrays as a 3D nano-biointerface for bacterial detection.
Zheng, Laibao; Wan, Yi; Qi, Peng; Sun, Yan; Zhang, Dun; Yu, Liangmin
2017-05-15
The detection of pathogenic bacteria is essential in various fields, such as food safety, water environmental analysis, or clinical diagnosis. Although rapid and selective techniques have been achieved based on the fast and specific binding of recognitions elements and target, the sensitive detection of bacterial pathogens was limited by their low targets-binding efficiency. The three-dimensional (3D) nano-biointerface, compared with the two-dimensional (2D) flat substrate, has a much higher binding capacity, which can offer more reactive sites to bind with bacterial targets, resulting in a great improvement of detection sensitivity. Herein, a lectin functionalized ZnO nanorod (ZnO-NR) array has been fabricated and employed as a 3D nano-biointerface for Escherichia coli (E. coli) capture and detection by multivalent binding of concanavalin A (ConA) with polysaccharides on the cellular surface of E. coli. The 3D lectin functionalized ZnO-NR array-based assay shows reasonable detection limit and efficiently expanded linear range (1.0×10 3 to 1.0×10 7 cfumL -1 ) for pathogen detection. The platform has a potential for further applications and provides an excellent sensitivity approach for detection of pathogenic bacteria. Copyright © 2017 Elsevier B.V. All rights reserved.
Roushani, Mahmoud; Shahdost-Fard, Faezeh
2018-03-12
The authors describe a highly sensitive method for the aptamer (Apt) based impedimetric determination of cocaine. The surface of a screen-printed electrode (SPE) was modified with a nanocomposite of dendrimer and silver nanoparticles (AgNPs). The cocaine-binding Apt was attached to a dendrimer/AgNP/SPE surface, forming a sensitive layer for the determination of cocaine. The incubation with the analyte resulted in the formation of a cocaine/Apt complex on the electrode surface. As a consequence, folding and conformational change in the aptamer structure was induced, this resulting in a change in the impedimetric signal. The aptaassay exhibits highly efficient sensing characteristics with a good linearity of 1 fmol L -1 to 100 nmol L -1 (with two linear ranges) and a limit of detection (LOD) of 333 amol L -1 . Its excellent specificity and high sensitivity suggest that this kind of aptamer-based assay may be applied to detect other targets in this field. Graphical Abstract Designing of an aptaassay via immobilization of a functionalized aptamer with silver nanoparticle (AgNPs-Apt) on the modified screen-printed electrode (SPE) with dendrimer/silver nanoparticle nanocomposite (Den-AgNPs) for impedimetric detection of cocaine.
Frati, F; Incorvaia, C; Cavaliere, C; Di Cara, G; Marcucci, F; Esposito, S; Masieri, S
2018-01-01
The skin prick test (SPT) is the most common test for the diagnosis of allergy. SPT is performed by pricking the skin, usually in the volar surface of the forearm, with a lancet through a drop of an allergen extract and is usually the first choice test in the diagnostic workup for allergic diseases because of its reliability, safety, convenience and low cost. SPT is minimally invasive and has the advantage of testing multiple allergens in 15 to 20 min. In children, SPT is far less disturbing than venipuncture and is used to obtain a sample of serum to measure specific IgE through in vitro tests. There is a good correlation (about 85-95%) between SPT and in vitro tests. Globally, SPT is an excellent diagnostic tool, with a positive predictive value ranging from 95-100%. SPTs can identify sensitivity to inhalants, foods, some drugs, occupational allergens, hymenoptera venom and latex. However, the relevance of such sensitivity to allergens should always be carefully interpreted in the light of the clinical history, because sensitization and clinical allergy may not coincide. In regards to safety, though the reports of systemic reactions, and particularly anaphylaxis, are very rare, in vitro IgE tests should be preferred if previous severe reactions emerge from the patients clinical history.
Non-destructive fraud detection in rosehip oil by MIR spectroscopy and chemometrics.
Santana, Felipe Bachion de; Gontijo, Lucas Caixeta; Mitsutake, Hery; Mazivila, Sarmento Júnior; Souza, Leticia Maria de; Borges Neto, Waldomiro
2016-10-15
Rosehip oil (Rosa eglanteria L.) is an important oil in the food, pharmaceutical and cosmetic industries. However, due to its high added value, it is liable to adulteration with other cheaper or lower quality oils. With this perspective, this work provides a new simple, fast and accurate methodology using mid-infrared (MIR) spectroscopy and partial least squares discriminant analysis (PLS-DA) as a means to discriminate authentic rosehip oil from adulterated rosehip oil containing soybean, corn and sunflower oils in different proportions. The model showed excellent sensitivity and specificity with 100% correct classification. Therefore, the developed methodology is a viable alternative for use in the laboratory and industry for standard quality analysis of rosehip oil since it is fast, accurate and non-destructive. Copyright © 2016 Elsevier Ltd. All rights reserved.
Ultrasonic humidification for telecommunications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Longo, F.
1994-03-01
This article examines two installations which demonstrate that ultrasonic humidification is an excellent option for large-scale commercial installations. Many existing telephone switching centers constructed 20 to 30 years ago were equipped with electro-mechanical switching equipment that was not sensitive to humidity. Today's sophisticated solid-state telecommunications equipment requires specific levels of relative humidity to operate properly. Over the last several years, Einhorn Yaffee Prescott (formerly Rose Beaton + Rose) designed two of the largest ultrasonic humidification systems at telecommunications buildings located in Cheshire, Conn., and White Plains, N.Y. The Cheshire project was a retrofit to the existing system in a 1960smore » building; the White Plains project involved an upgrade to a totally new air handling system, including an ultrasonic humidification component, in a 1950s building.« less
Oligonucleotide-based biosensors for in vitro diagnostics and environmental hazard detection.
Jung, Il Young; Lee, Eun Hee; Suh, Ah Young; Lee, Seung Jin; Lee, Hyukjin
2016-04-01
Oligonucleotide-based biosensors have drawn much attention because of their broad applications in in vitro diagnostics and environmental hazard detection. They are particularly of interest to many researchers because of their high specificity as well as excellent sensitivity. Recently, oligonucleotide-based biosensors have been used to achieve not only genetic detection of targets but also the detection of small molecules, peptides, and proteins. This has further broadened the applications of these sensors in the medical and health care industry. In this review, we highlight various examples of oligonucleotide-based biosensors for the detection of diseases, drugs, and environmentally hazardous chemicals. Each example is provided with detailed schematics of the detection mechanism in addition to the supporting experimental results. Furthermore, future perspectives and new challenges in oligonucleotide-based biosensors are discussed.
Montillet, Marie; Baqué-Juston, Marie; Tasu, Jean-Pierre; Bertrand, Sandra; Berthier, Frédéric; Zarqane, Naïma; Brunner, Philippe
2018-03-01
The purpose of this study is to describe a new method to quickly estimate left atrial enlargement (LAE) on Computed Tomography. Left atrial (LA) volume was assessed with a 3D-threshold Hounsfield unit detection technique, including left atrial appendage and excluding pulmonary venous confluence, in 201 patients with ECG-gated 128-slice dual-source CT and indexed to body surface area. LA and vertebral axial diameter and area were measured at the bottom level of the right inferior pulmonary vein ostium. Ratio of LA diameter and surface on vertebra (LAVD and LAVA) were compared to LA volume. In accordance with the literature, a cutoff value of 78 ml/m 2 was chosen for maximal normal LA volume. 18% of LA was enlarged. The best cutoff values for LAE assessment were 2.5 for LAVD (AUC: 0.65; 95% CI: 0.58-0.73; sensitivity: 57%; specificity: 71%), and 3 for LAVA (AUC: 0.78; 95% CI: 0.72-0.84; sensitivity: 67%; specificity: 79%), with higher accuracy for LAVA (P=0.015). Inter-observer and intra-observer variability were either good or excellent for LAVD and LAVA (respective intraclass coefficients: 0.792 and 0.910; 0.912 and 0.937). A left atrium area superior to three times the vertebral area indicates LAE with high specificity. • Left atrial enlargement is a frequent condition associated with poor cardiac outcome. • Left atrial enlargement is highly time-consuming to diagnose on CT. • The left atrio-vertebral ratio quickly assesses left atrial enlargement. • A left atrial area > three times vertebral area is highly specific.
Skjerning, Halfdan; Hourihane, Jonathan; Husby, Steffen; DunnGalvin, Audrey
2017-10-01
Coeliac disease (CD) is a chronic immune-mediated disease in genetically susceptible individuals, induced by ingested gluten. The treatment for CD is a lifelong gluten-free diet (GFD). The GFD involves restrictions in diet that may impact on a person's Health-Related Quality of Life (HRQoL). The aim of the present study was to develop the Coeliac Disease Quality of Life questionnaire (CDQL): a comprehensive CD-specific HRQoL measure that can be completed by children, adolescents, and adults or by proxy. The questionnaire was developed in three phases. In phase 1, focus group methods and qualitative analysis of verbatim transcripts generated CD-specific items for a prototype instrument to sensitively captured patient concerns. In phase 2, CD patients completed the prototype CDQL. The questionnaire was refined through analysis of data and cognitive interviewing. In phase 3, the final version of the CDQL was answered by Danish respondents. The psychometric properties of the CDQL were assessed, and the HRQoL data were analyzed. The CDQL was completed by 422 respondents. The CDQL has 12 patient background items, 2 generic HRQoL items, and 30 CD-specific HRQoL item. The CD-specific HRQoL items were distributed on eight scales with acceptable to excellent reliability. Comprehensiveness and understandability was shown by feedback from cognitive interviewing from children, adolescents, and adults. Content validity was ensured by involving patients and clinicians in the development of the questionnaire. Sensitivity of the questionnaire was demonstrated in differences found between children, adolescents, and adult's perception of their HRQoL in relation to having CD. The CDQL comprehensively measures HRQoL in CD, and is psychometrically robust. The questionnaire may prove useful in tracking HRQoL in CD across age groups.
Camargos, Paulo; Fonseca, Ana Cristina; Amantéa, Sérgio; Oliveira, Elizabeth; Benfica, Maria das Graças; Chamone, Chequer
2017-05-01
The etiological diagnosis of pleural effusion is a difficult task because the diagnostic tools can only establish a definitive etiological diagnosis in at most 76% of cases. To verify the diagnostic accuracy of the latex agglutination test (LAT) for the etiological diagnosis of pleural effusions caused by Streptococcus pneumoniae and Haemophilus influenzae type b. After thoracocentesis, paired fresh samples of pleural fluid from 418 children and adolescents were included in this investigation. They were tested blindly and simultaneously through counterimmunoelectrophoresis (CIE) and LAT for both bacteria. Sensitivity, specificity, predictive values and likelihood ratios (LR) were calculated taking CIE as a reference standard. The sensitivity and specificity of LAT was 100% (95% confidence interval, 94.4%-100%) and 83.3% (95% confidence interval, 79.0%-87.0%), respectively, whereas the positive (calculated from Bayes' theorem) and negative predictive values were, respectively, lower than 1% and 100% (95% confidence interval, 98.8%-100%). Positive and negative LR were 6.0 (95% confidence interval, 4.7-7.6) and zero, respectively. Our results suggest that LAT is a useful tool for the etiological diagnosis of pleural effusion. It is a reliable, rapid, simple to perform and shows an excellent yield in our studied population, helping to prescribe appropriate antibiotics for this clinical condition. © 2015 John Wiley & Sons Ltd.
Novel assay procedures for the measurement of α-amylase in weather-damaged wheat.
Cornaggia, Claudio; Ivory, Ruth; Mangan, David; McCleary, Barry V
2016-01-30
The measurement of α-amylase (EC 3.2.1.1) in sprout-damaged grains is a crucial analysis yet a problematic one owing to the typically low α-amylase levels in ground wheat samples. A number of standardised methods such as the Falling Number method and the Ceralpha method exist which are routinely used for the assay of α-amylase. These methods, however, are either highly substrate-dependent or lack the required sensitivity to assess sprout damage. Novel colorimetric and fluorometric reagents have been prepared (Amylase HR, Amylase SD, BzCNPG7 reagent and BzMUG7 reagent) for the direct and specific assay of α-amylase activity in sprout-damaged wheat. Assays employing these reagents have been developed and optimised to include a decolourisation step using activated charcoal. When used in a convenient assay format, Amylase SD--containing EtNPG7 (II) as the colorimetric substrate and α-glucosidase as the ancillary enzyme--was found to be an excellent reagent for the assessment of sprout damage in wheat with incubation times as short as 5 min. The assay using Amylase SD is completely specific for α-amylase. The use of the Amylase SD assay represents a sensitive and valid alternative to the traditionally used Falling Number values for the assessment of sprout damage in wheat samples. © 2015 Society of Chemical Industry.
Goswami, R; Pi, D; Pal, J; Cheng, K; Hudoba De Badyn, M
2015-06-01
The study evaluated the performance of a dynamic imaging telepathology system (Panoptiq(™) ) as a diagnostic aid to the identification of peripheral blood film (PBF) abnormalities. The study assumed a laboratory personnel working in a clinical laboratory were operating the telepathology system to seek diagnostic opinion from an external consulting hematopathologist. The study examined 100 blood films, encompassing 23 different hematological diseases, reactive or normal cases. The study revealed that with real-time image transmission in live scanning mode of operation, the telepathology system was able to aid reviewers in achieving excellent accuracy, that is correct interpretation of morphologic abnormalities obtained in 83/84 of the hematologic diseases and 12/12 of the reactive/normal conditions (Sensitivity: 0.99; Specificity: 1.00). In contrast, when only saved static images in digital capture mode of operation were reviewed remotely, interpretative omissions occurred in 8/84 of the hematologic diseases and 0/12 of the reactive/normal conditions (Sensitivity: 0.91; Specificity: 1.00). It is hypothesized that real-time operator-reviewer communication during live scanning played an important role in the identification of key morphologic abnormalities for review. Our study showed the Panoptiq system can be adopted reliably as a dynamic telepathology tool in aiding community laboratories in the triage of PBF cases for external diagnostic consultation. © 2014 John Wiley & Sons Ltd.
Detection of brain tumor margins using optical coherence tomography
NASA Astrophysics Data System (ADS)
Juarez-Chambi, Ronald M.; Kut, Carmen; Rico-Jimenez, Jesus; Campos-Delgado, Daniel U.; Quinones-Hinojosa, Alfredo; Li, Xingde; Jo, Javier
2018-02-01
In brain cancer surgery, it is critical to achieve extensive resection without compromising adjacent healthy, noncancerous regions. Various technological advances have made major contributions in imaging, including intraoperative magnetic imaging (MRI) and computed tomography (CT). However, these technologies have pros and cons in providing quantitative, real-time and three-dimensional (3D) continuous guidance in brain cancer detection. Optical Coherence Tomography (OCT) is a non-invasive, label-free, cost-effective technique capable of imaging tissue in three dimensions and real time. The purpose of this study is to reliably and efficiently discriminate between non-cancer and cancerinfiltrated brain regions using OCT images. To this end, a mathematical model for quantitative evaluation known as the Blind End-Member and Abundances Extraction method (BEAE). This BEAE method is a constrained optimization technique which extracts spatial information from volumetric OCT images. Using this novel method, we are able to discriminate between cancerous and non-cancerous tissues and using logistic regression as a classifier for automatic brain tumor margin detection. Using this technique, we are able to achieve excellent performance using an extensive cross-validation of the training dataset (sensitivity 92.91% and specificity 98.15%) and again using an independent, blinded validation dataset (sensitivity 92.91% and specificity 86.36%). In summary, BEAE is well-suited to differentiate brain tissue which could support the guiding surgery process for tissue resection.
Detection of brain tumor margins using optical coherence tomography
NASA Astrophysics Data System (ADS)
Juarez-Chambi, Ronald M.; Kut, Carmen; Rico-Jimenez, Jesus; Campos-Delgado, Daniel U.; Quinones-Hinojosa, Alfredo; Li, Xingde; Jo, Javier
2018-02-01
In brain cancer surgery, it is critical to achieve extensive resection without compromising adjacent healthy, non-cancerous regions. Various technological advances have made major contributions in imaging, including intraoperative magnetic imaging (MRI) and computed tomography (CT). However, these technologies have pros and cons in providing quantitative, real-time and three-dimensional (3D) continuous guidance in brain cancer detection. Optical Coherence Tomography (OCT) is a non-invasive, label-free, cost-effective technique capable of imaging tissue in three dimensions and real time. The purpose of this study is to reliably and efficiently discriminate between non-cancer and cancer-infiltrated brain regions using OCT images. To this end, a mathematical model for quantitative evaluation known as the Blind End- Member and Abundances Extraction method (BEAE). This BEAE method is a constrained optimization technique which extracts spatial information from volumetric OCT images. Using this novel method, we are able to discriminate between cancerous and non-cancerous tissues and using logistic regression as a classifier for automatic brain tumor margin detection. Using this technique, we are able to achieve excellent performance using an extensive cross-validation of the training dataset (sensitivity 92.91% and specificity 98.15%) and again using an independent, blinded validation dataset (sensitivity 92.91% and specificity 86.36%). In summary, BEAE is well-suited to differentiate brain tissue which could support the guiding surgery process for tissue resection.
2011-01-01
Background In this study, we developed a rapid, one step colloid gold strip (CGS) capable of specifically detecting type Asia1 foot-and-mouth disease virus (FMDV). We have produced two monoclonal antibodies (mAb) to type Asia1 FMD (named 1B8 and 5E2). On the test strip, the purified 1B8 labelled with the colloidal gold was used as the detector, and the purified 5E2 and goat anti-mouse antibodies were wrapped onto nitrocellulose (NC) membranes as the test and the control line, respectively. The rapid colloidal gold stereotype diagnostic strip was housed in a plastic case. Results In specificity and sensitivity assay, there was no cross-reaction of the antigen with the other type of FMD and SVDV. The detection sensitivity was found to be as high as 10-5 dilution of Asia1/JSL/05 (1 × 107.2TCID50/50 μL). There was excellent agreement between the results obtained by CGS and reverse indirect hemagglutination assay (RIHA), and the agreement can reach to 98.75%. Conclusion We developed colloidal gold strips that have good qualities and does not require specialized equipment or technicians. This method provided a feasible, convenient, rapid, and effective for detecting type Asia1 FMDV in the fields. PMID:21880157
Sosic, Z; Gieler, U; Stangier, U
2008-06-01
To evaluate the German version of the Social Phobia Inventory (SPIN) as a screening device and to report corresponding cut-off scores for different populations. In Study 1, 2043 subjects from a representative sample completed the SPIN. Cut-off values were established on the basis of means and standard deviations. In Study 2, different aspects of validity were examined in a clinical sample comprising 164 subjects, including social phobic individuals, individuals with other anxiety disorders and depression, and non-clinical control subjects. Internal consistency was evaluated. Convergent and divergent validity were explored using several established measures. Finally, the sensitivity and specificity of the German SPIN with regard to social anxiety classification were investigated by means of receiver operating characteristics (ROC) analyses. In Study 1, mean scores and standard deviations were used to determine cut-off scores for the German SPIN. In Study 2, excellent internal consistency and good convergent and divergent validity were obtained. ROC analyses revealed that the German SPIN performed well in discriminating between social phobic individuals on the one hand and psychiatric and non-psychiatric controls on the other. A cut-off score of 25 represented the best balance between sensitivity and specificity. Comparable to the original version, the German SPIN demonstrates solid psychometric properties and shows promise as an economic, reliable, and valid screening device.
Parcell, Benjamin J; Jarchow-MacDonald, Anna A; Seagar, Amie-Louise; Laurenson, Ian F; Prescott, Gordon J; Lockhart, Michael
2017-05-01
Xpert MTB/RIF (Cepheid) is a rapid molecular assay shown to be sensitive and specific for pulmonary tuberculosis (TB) diagnosis in highly endemic countries. We evaluated its diagnostic performance in a low TB prevalence setting, examined rifampicin resistance detection and quantitative capabilities predicting graded auramine microscopy and time to positivity (TTP) of culture. Xpert MTB/RIF was used to test respiratory samples over a 3 year period. Samples underwent graded auramine microscopy, solid/liquid culture, in-house IS6110 real-time PCR, and GenoType MTBDRplus (HAIN Lifescience) to determine rifampicin and/or isoniazid resistance. A total of 2103 Xpert MTB/RIF tests were performed. Compared to culture sensitivity was 95.8%, specificity 99.5%, positive predictive value (PPV) 82.1%, and negative predictive value (NPV) 99.9%. A positive correlation was found between auramine microscopy grade and Xpert MTB/RIF assay load. We found a clear reduction in the median TTP as Xpert MTB/RIF assay load increased. Rifampicin resistance was detected. Xpert MTB/RIF was rapid and accurate in diagnosing pulmonary TB in a low prevalence area. Rapid results will influence infection prevention and control and treatment measures. The excellent NPV obtained suggests further work should be carried out to assess its role in replacing microscopy. Copyright © 2017 The British Infection Association. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Tsuchiya, Yuichiro; Kodera, Yoshie
2006-03-01
In the picture archiving and communication system (PACS) environment, it is important that all images be stored in the correct location. However, if information such as the patient's name or identification number has been entered incorrectly, it is difficult to notice the error. The present study was performed to develop a system of patient collation automatically for dynamic radiogram examination by a kinetic analysis, and to evaluate the performance of the system. Dynamic chest radiographs during respiration were obtained by using a modified flat panel detector system. Our computer algorithm developed in this study was consisted of two main procedures, kinetic map imaging processing, and collation processing. Kinetic map processing is a new algorithm to visualize a movement for dynamic radiography; direction classification of optical flows and intensity-density transformation technique was performed. Collation processing consisted of analysis with an artificial neural network (ANN) and discrimination for Mahalanobis' generalized distance, those procedures were performed to evaluate a similarity of combination for the same person. Finally, we investigated the performance of our system using eight healthy volunteers' radiographs. The performance was shown as a sensitivity and specificity. The sensitivity and specificity for our system were shown 100% and 100%, respectively. This result indicated that our system has excellent performance for recognition of a patient. Our system will be useful in PACS management for dynamic chest radiography.
Accuracy of MSCT Coronary Angiography with 64 Row CT Scanner—Facing the Facts
Wehrschuetz, M.; Wehrschuetz, E.; Schuchlenz, H.; Schaffler, G.
2010-01-01
Improvements in multislice computed tomography (MSCT) angiography of the coronary vessels have enabled the minimally invasive detection of coronary artery stenoses, while quantitative coronary angiography (QCA) is the accepted reference standard for evaluation thereof. Sixteen-slice MSCT showed promising diagnostic accuracy in detecting coronary artery stenoses haemodynamically and the subsequent introduction of 64-slice scanners promised excellent and fast results for coronary artery studies. This prompted us to evaluate the diagnostic accuracy, sensitivity, specificity, and the negative und positive predictive value of 64-slice MSCT in the detection of haemodynamically significant coronary artery stenoses. Thirty-seven consecutive subjects with suspected coronary artery disease were evaluated with MSCT angiography and the results compared with QCA. All vessels were considered for the assessment of significant coronary artery stenosis (diameter reduction ≥ 50%). Thirteen patients (35%) were identified as having significant coronary artery stenoses on QCA with 6.3% (35/555) affected segments. None of the coronary segments were excluded from analysis. Overall sensitivity for classifying stenoses of 64-slice MSCT was 69%, specificity was 92%, positive predictive value was 38% and negative predictive value was 98%. The interobserver variability for detection of significant lesions had a k-value of 0.43. Sixty-four-slice MSCT offers the diagnostic potential to detect coronary artery disease, to quantify haemodynamically significant coronary artery stenoses and to avoid unnecessary invasive coronary artery examinations. PMID:20567636
Simultaneous point-of-care detection of anemia and sickle cell disease in Tanzania: the RAPID study.
Smart, Luke R; Ambrose, Emmanuela E; Raphael, Kevin C; Hokororo, Adolfine; Kamugisha, Erasmus; Tyburski, Erika A; Lam, Wilbur A; Ware, Russell E; McGann, Patrick T
2018-02-01
Both anemia and sickle cell disease (SCD) are highly prevalent across sub-Saharan Africa, and limited resources exist to diagnose these conditions quickly and accurately. The development of simple, inexpensive, and accurate point-of-care (POC) assays represents an important advance for global hematology, one that could facilitate timely and life-saving medical interventions. In this prospective study, Robust Assays for Point-of-care Identification of Disease (RAPID), we simultaneously evaluated a POC immunoassay (Sickle SCAN™) to diagnose SCD and a first-generation POC color-based assay to detect anemia. Performed at Bugando Medical Center in Mwanza, Tanzania, RAPID tested 752 participants (age 1 day to 20 years) in four busy clinical locations. With minimally trained medical staff, the SCD POC assay diagnosed SCD with 98.1% sensitivity and 91.1% specificity. The hemoglobin POC assay had 83.2% sensitivity and 74.5% specificity for detection of severe anemia (Hb ≤ 7 g/dL). Interobserver agreement was excellent for both POC assays (r = 0.95-0.96). Results for the hemoglobin POC assay have informed the second-generation assay design to be more suitable for low-resource settings. RAPID provides practical feasibility data regarding two novel POC assays for the diagnosis of anemia and SCD in real-world field evaluations and documents the utility and potential impact of these POC assays for sub-Saharan Africa.
Wang, Lan; Gao, Zhiyong; Chang, Jiuli; Liu, Xiao; Wu, Dapeng; Xu, Fang; Guo, Yuming; Jiang, Kai
2015-09-16
Activated N-doped porous carbons (a-NCs) were synthesized by pyrolysis and alkali activation of graphene incorporated melamine formaldehyde resin (MF). The moderate N doping levels, mesopores rich porous texture, and incorporation of graphene enable the applications of a-NCs in surface and conductivity dependent electrode materials for supercapacitor and dye-sensitized solar cell (DSSC). Under optimal activation temperature of 700 °C, the afforded sample, labeled as a-NC700, possesses a specific surface area of 1302 m2 g(-1), a N fraction of 4.5%, and a modest graphitization. When used as a supercapacitor electrode, a-NC700 offers a high specific capacitance of 296 F g(-1) at a current density of 1 A g(-1), an acceptable rate capability, and a high cycling stability in 1 M H2SO4 electrolyte. As a result, a-NC700 supercapacitor delivers energy densities of 5.0-3.5 Wh kg(-1) under power densities of 83-1609 W kg(-1). Moreover, a-NC700 also demonstrates high electrocatalytic activity for I3- reduction. When employed as a counter electrode (CE) of DSSC, a power conversion efficiency (PCE) of 6.9% is achieved, which is comparable to that of the Pt CE based counterpart (7.1%). The excellent capacitive and photovoltaic performances highlight the potential of a-NCs in sustainable energy devices.
González, Segundo Jaime; González, Lorena; Wong, Joyce; Brader, Peter; Zakowski, Maureen; Gönen, Mithat; Daghighian, Farhad; Fong, Yuman
2012-01-01
Introduction The intraoperative localization of suspicious lesions detected by positron emission tomography (PET) scan remains a challenge. To solve this, two novel probes have been created to accurately detect the 18F-FDG radiotracer intraoperatively. Methods Nude rats were inoculated with mesothelioma. When PET scans detected 10-mm tumors, animals were dissected and the PET probes analyzed the intraoperative radiotracer uptake of these lesions as tumor to background ratio (TBR). Results The 17 suspicious lesions seen on PET scan were localized intraoperatively (by their high TBR) using the PET probes and found malignant on pathology. Interestingly, smaller tumors not visualized on PET scan were detected intraoperatively by their high TBR and found malignant on pathology. Furthermore, using a TBR threshold as low as 2.0, both gamma (sensitivity, 100%; specificity, 80%; positive predictive value (PPV), 96%; and negative predictive value (NPV), 100%) and beta (sensitivity, 100%; specificity, 60%; PPV, 93%; and NPV, 100%) probes reliably detected suspicious lesions on PET scan imaging. They also showed an excellent area under the curve of 0.9 and 0.97 (95% CI of 0.81–0.99 and 0.93–1.0) for gamma and beta probes, respectively, in the receiver operating characteristic analysis for detecting malignancy. Conclusion This novel tool could be used synergistically with a PET scan imaging to maximize tissue selection intraoperatively. PMID:21108016
Lin, Tong; Shao, Jun-jun; Du, Jun-zheng; Cong, Guo-zheng; Gao, Shan-dian; Chang, Huiyun
2011-09-01
In this study, we developed a rapid, one step colloid gold strip (CGS) capable of specifically detecting type Asia1 foot-and-mouth disease virus (FMDV). We have produced two monoclonal antibodies (mAb) to type Asia1 FMD (named 1B8 and 5E2). On the test strip, the purified 1B8 labelled with the colloidal gold was used as the detector, and the purified 5E2 and goat anti-mouse antibodies were wrapped onto nitrocellulose (NC) membranes as the test and the control line, respectively. The rapid colloidal gold stereotype diagnostic strip was housed in a plastic case. In specificity and sensitivity assay, there was no cross-reaction of the antigen with the other type of FMD and SVDV. The detection sensitivity was found to be as high as 10(-5) dilution of Asia1/JSL/05 (1 × 10(7.2)TCID(50)/50 μL). There was excellent agreement between the results obtained by CGS and reverse indirect hemagglutination assay (RIHA), and the agreement can reach to 98.75%. We developed colloidal gold strips that have good qualities and does not require specialized equipment or technicians. This method provided a feasible, convenient, rapid, and effective for detecting type Asia1 FMDV in the fields.
Development of an ultrasensitive aptasensor for the detection of aflatoxin B1.
Guo, Xiaodong; Wen, Fang; Zheng, Nan; Luo, Qiujiang; Wang, Haiwei; Wang, Hui; Li, Songli; Wang, Jiaqi
2014-06-15
Contamination of feed and food by aflatoxin B1 (AFB1), one of the most toxic of the mycotoxins, is a global concern. To prevent food safety scares, and avoid subsequent economic losses due to the recall of contaminated items, methods for the rapid, sensitive and specific detection of AFB1 at trace levels are much in demand. In this work, a simple, ultrasensitive, and reliable aptasensor is described for the detection of AFB1. An AFB1 aptamer was used as a molecular recognition probe, while its complementary DNA played a role as a signal generator for amplification by real-time quantitative polymerase chain reaction (PCR). Under optimal conditions, a wide linear detection range (5.0 × 10(-5) to 5.0 ng mL(-1)) was achieved, with a high sensitivity (limit of detection (LOD)=25 fg mL(-1)). In addition, the proposed aptasensor exhibited excellent specificity for AFB1 compared with eight other mycotoxins, with no obvious Ct value change. This aptasensor can also be used in quantifying AFB1 levels in Chinese wild rye hay samples and infant rice cereal samples, demonstrating satisfactory recoveries in the range of 88-127% and 94-119%, respectively. This detection technique has a significant potential for high-throughput, quantitative determination of mycotoxin levels in a large range of feeds and foods. Copyright © 2014 Elsevier B.V. All rights reserved.
Imširović, Bilal; Zerem, Enver; Efendić, Alma; Mekić Abazović, Alma; Zerem, Omar; Djedović, Muhamed
2018-08-01
Aim To determine capabilities and potential of contrast enhanced magnetic resonance imaging (MRI) enterography in order to establish the diagnosis and to evaluate severity and activity of intestinal inflammation. Methods Fifty-five patients with suspicion for presence of Crohn's disease were evaluated. All patients underwent contrast enhanced MRI enterography and diffusion weighted imaging (DWI), and subsequently endoscopic examination or surgical treatment. Four parameters were analysed: thickening of the bowel wall, and presence of abscess, fistula and lymphadenopathy. Results Comparing results of DWI and contrast enhanced MRI enterography a significant difference between results given through diffusion and histopathological test was found, e.g. a significant difference between results obtained through diffusion and MRI enterography was found. MRI enterography sensitiveness for bowel wall thickening was 97.7% and specificity 70%, whilst DWI sensitivity for bowel wall thickening was 84% and specificity 100%. The diagnostics of abscess and fistula showed no significant difference between DWI and MRI, while in lymphadenopathy significant difference between contrast enhanced MRI enterography and DWI was found. Conclusion Contrast enhanced MRI enterography in combination with DWI allows for excellent evaluation of disease activity, but also problems or complications following it. The examination can be repeated, controlled, and it can contribute to monitoring of patients with this disease. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.
The London field trial for hoarding disorder.
Mataix-Cols, D; Billotti, D; Fernández de la Cruz, L; Nordsletten, A E
2013-04-01
A new diagnostic category, hoarding disorder (HD), has been proposed for inclusion in DSM-5. This study field-tested the validity, reliability and perceived acceptability of the proposed diagnostic criteria for HD. Method Fifty unselected individuals with prominent hoarding behavior and 20 unselected, self-defined 'collectors' participated in thorough psychiatric assessments, involving home visits whenever possible. A semi-structured interview based on the proposed diagnostic criteria for HD was administered and scored by two independent raters. 'True' diagnoses were made by consensus according to the best-estimate diagnosis procedure. The percentage of true positive HD cases (sensitivity) and true negative HD cases (specificity) was calculated, along with inter-rater reliability for the diagnosis and each criterion. Participants were asked about their perceptions of the acceptability, utility and stigma associated with the new diagnosis. Twenty-nine (58%) of the hoarding individuals and none of the collectors fulfilled diagnostic criteria for HD. The sensitivity, specificity and inter-rater reliability of the diagnosis, and of each individual criterion and the specifiers, were excellent. Most participants with HD (96%) felt that creating a new disorder would be very or somewhat acceptable, useful (96%) and not too stigmatizing (59%). The proposed HD criteria are valid, reliable and perceived as acceptable and useful by the sufferers. Crucially, they seem to be sufficiently conservative and unlikely to overpathologize normative behavior. Minor changes in the wording of the criteria are suggested.
Ma, Chao; Ouyang, Jihong; Chen, Hui-Ling; Zhao, Xue-Hua
2014-01-01
A novel hybrid method named SCFW-KELM, which integrates effective subtractive clustering features weighting and a fast classifier kernel-based extreme learning machine (KELM), has been introduced for the diagnosis of PD. In the proposed method, SCFW is used as a data preprocessing tool, which aims at decreasing the variance in features of the PD dataset, in order to further improve the diagnostic accuracy of the KELM classifier. The impact of the type of kernel functions on the performance of KELM has been investigated in detail. The efficiency and effectiveness of the proposed method have been rigorously evaluated against the PD dataset in terms of classification accuracy, sensitivity, specificity, area under the receiver operating characteristic (ROC) curve (AUC), f-measure, and kappa statistics value. Experimental results have demonstrated that the proposed SCFW-KELM significantly outperforms SVM-based, KNN-based, and ELM-based approaches and other methods in the literature and achieved highest classification results reported so far via 10-fold cross validation scheme, with the classification accuracy of 99.49%, the sensitivity of 100%, the specificity of 99.39%, AUC of 99.69%, the f-measure value of 0.9964, and kappa value of 0.9867. Promisingly, the proposed method might serve as a new candidate of powerful methods for the diagnosis of PD with excellent performance.
Ma, Chao; Ouyang, Jihong; Chen, Hui-Ling; Zhao, Xue-Hua
2014-01-01
A novel hybrid method named SCFW-KELM, which integrates effective subtractive clustering features weighting and a fast classifier kernel-based extreme learning machine (KELM), has been introduced for the diagnosis of PD. In the proposed method, SCFW is used as a data preprocessing tool, which aims at decreasing the variance in features of the PD dataset, in order to further improve the diagnostic accuracy of the KELM classifier. The impact of the type of kernel functions on the performance of KELM has been investigated in detail. The efficiency and effectiveness of the proposed method have been rigorously evaluated against the PD dataset in terms of classification accuracy, sensitivity, specificity, area under the receiver operating characteristic (ROC) curve (AUC), f-measure, and kappa statistics value. Experimental results have demonstrated that the proposed SCFW-KELM significantly outperforms SVM-based, KNN-based, and ELM-based approaches and other methods in the literature and achieved highest classification results reported so far via 10-fold cross validation scheme, with the classification accuracy of 99.49%, the sensitivity of 100%, the specificity of 99.39%, AUC of 99.69%, the f-measure value of 0.9964, and kappa value of 0.9867. Promisingly, the proposed method might serve as a new candidate of powerful methods for the diagnosis of PD with excellent performance. PMID:25484912
Eddy current-shielded x-space relaxometer for sensitive magnetic nanoparticle characterization
Bauer, L. M.; Hensley, D. W.; Zheng, B.; Tay, Z. W.; Goodwill, P. W.; Griswold, M. A.; Conolly, S. M.
2016-01-01
The development of magnetic particle imaging (MPI) has created a need for optimized magnetic nanoparticles. Magnetic particle relaxometry is an excellent tool for characterizing potential tracers for MPI. In this paper, we describe the design and construction of a high-throughput tabletop relaxometer that is able to make sensitive measurements of MPI tracers without the need for a dedicated shield room. PMID:27250472
Eddy current-shielded x-space relaxometer for sensitive magnetic nanoparticle characterization.
Bauer, L M; Hensley, D W; Zheng, B; Tay, Z W; Goodwill, P W; Griswold, M A; Conolly, S M
2016-05-01
The development of magnetic particle imaging (MPI) has created a need for optimized magnetic nanoparticles. Magnetic particle relaxometry is an excellent tool for characterizing potential tracers for MPI. In this paper, we describe the design and construction of a high-throughput tabletop relaxometer that is able to make sensitive measurements of MPI tracers without the need for a dedicated shield room.
Liyanage, Thakshila; Rael, Ashur; Shaffer, Sidney; Zaidi, Shozaf; Goodpaster, John V; Sardar, Rajesh
2018-04-30
Apart from high sensitivity and selectivity of surface-enhanced Raman scattering (SERS)-based trace explosive detection, efficient sampling of explosive residue from real world surfaces is very important for homeland security applications. Herein, we demonstrate an entirely new SERS nanosensor fabrication approach. The SERS nanosensor was prepared by self-assembling chemically synthesized gold triangular nanoprisms (Au TNPs), which we show display strong electromagnetic field enhancements at the sharp tips and edges, onto a pressure-sensitive flexible adhesive film. Our SERS nanosensor provides excellent SERS activity (enhancement factor = ∼6.0 × 106) and limit of detection (as low as 56 parts-per-quadrillions) with high selectivity by chemometric analyses among three commonly military high explosives (TNT, RDX, and PETN). Furthermore, the SERS nanosensors present excellent reproducibility (<4.0% relative standard deviation at 1.0 μM concentration) and unprecedentedly high stability with a "shelf life" of at least 5 months. Finally, TNT and PETN were analyzed and quantified by transferring solid explosive residues from fingerprints left on solid surfaces to the SERS nanosensor. Taken together, the demonstrated sensitivity, selectivity, and reliability of the measurements as well as with the excellent shelf life of our SERS nanosensors obviate the need for complicated sample processing steps required for other analytical techniques, and thus these nanosensors have tremendous potential not only in the field of measurement science but also for homeland security applications to combat acts of terror and military threats.
Rachakonda, Tara; Jeffe, Donna B; Shin, Jennifer J; Mankarious, Leila; Fanning, Robert J; Lesperance, Marci M; Lieu, Judith E C
2014-02-01
The prevalence of hearing loss (HL) in adolescents has grown over the past decade, but hearing-related quality of life (QOL) has not been well-measured. We sought to develop a reliable, valid measure of hearing-related QOL for adolescents and the Hearing Environments And Reflection on Quality of Life (HEAR-QL). Multisite observational study. Adolescents with HL and siblings without HL were recruited from five centers. Participants completed the HEAR-QL and validated questionnaires measuring generic pediatric QOL (PedsQL), depression and anxiety (RCADS-25), and hearing-related QOL for adults (HHIA) to determine construct and discriminant validity. Participants completed the HEAR-QL 2 weeks later for test-retest reliability. We used exploratory principal components analysis to determine the HEAR-QL factor structure and measured reliability. Sensitivity and specificity of the HEAR-QL, PedsQL, HHIA, and RCADS-25 were assessed. We compared scores on all surveys between those with normal hearing, unilateral, and bilateral HL. A total of 233 adolescents (13-18 years old) participated: 179 with HL, 54 without HL. The original 45-item HEAR-QL was shortened to 28 items after determining factor structure. The resulting HEAR-QL-28 demonstrated excellent reliability (Cronbach's alpha = 0.95) and construct validity (HHIA: r = .845, PedsQL: r = .587; RCADS-25: r = .433). The HEAR-QL-28 displayed excellent discriminant validity, with higher area under the curve (0.932) than the PedsQL (0.597) or RCADS-25 (0.529). Teens with bilateral HL using hearing devices reported worse QOL on the HEAR-QL and HHIA than peers with HL not using devices. The HEAR-QL is a sensitive, reliable, and valid measure of hearing-related QOL for adolescents. 2b. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.
Rachakonda, Tara; Jeffe, Donna B.; Shin, Jennifer J.; Mankarious, Leila; Fanning, Robert J.; Lesperance, Marci M.; Lieu, Judith E.C.
2014-01-01
Objectives The prevalence of hearing loss (HL) in adolescents has grown over the past decade, but hearing-related quality of life (QOL) has not been well-measured. We sought to develop a reliable, valid measure of hearing-related QOL for adolescents, the Hearing Environments And Reflection on Quality of Life (HEAR-QL). Study Design Multi-site observational study. Methods Adolescents with HL and siblings without HL were recruited from five centers. Participants completed the HEAR-QL and validated questionnaires measuring generic pediatric QOL (PedsQL), depression and anxiety (RCADS-25), and hearing-related QOL for adults (HHIA) to determine construct and discriminant validity. Participants completed the HEAR-QL two weeks later for test-retest reliability. We used exploratory principal components analysis to determine the HEAR-QL factor structure and measured reliability. Sensitivity and specificity of the HEAR-QL, PedsQL, HHIA and RCADS-25 were assessed. We compared scores on all surveys between those with normal hearing, unilateral and bilateral HL. Results 233 adolescents (13–18 years old) participated—179 with HL, 54 without HL. The original 45-item HEAR-QL was shortened to 28 items after determining factor structure. The resulting HEAR-QL-28 demonstrated excellent reliability (Cronbach’s alpha= 0.95) and construct validity (HHIA: r =.845, PedsQL: r =.587; RCADS-25: r =.433). The HEAR-QL-28 displayed excellent discriminant validity, with higher area under the curve (0.932) than the PedsQL (0.597) or RCADS-25 (0.529). Teens with bilateral HL using hearing devices reported worse QOL on the HEAR-QL and HHIA than peers with HL not using devices. Conclusions The HEAR-QL is a sensitive, reliable and valid measure of hearing-related QOL for adolescents. PMID:23900836
Gupta, Sumit; Nathan, Paul C; Baxter, Nancy N; Lau, Cindy; Daly, Corinne; Pole, Jason D
2018-06-01
Despite the importance of estimating population level cancer outcomes, most registries do not collect critical events such as relapse. Attempts to use health administrative data to identify these events have focused on older adults and have been mostly unsuccessful. We developed and tested administrative data-based algorithms in a population-based cohort of adolescents and young adults with cancer. We identified all Ontario adolescents and young adults 15-21 years old diagnosed with leukemia, lymphoma, sarcoma, or testicular cancer between 1992-2012. Chart abstraction determined the end of initial treatment (EOIT) date and subsequent cancer-related events (progression, relapse, second cancer). Linkage to population-based administrative databases identified fee and procedure codes indicating cancer treatment or palliative care. Algorithms determining EOIT based on a time interval free of treatment-associated codes, and new cancer-related events based on billing codes, were compared with chart-abstracted data. The cohort comprised 1404 patients. Time periods free of treatment-associated codes did not validly identify EOIT dates; using subsequent codes to identify new cancer events was thus associated with low sensitivity (56.2%). However, using administrative data codes that occurred after the EOIT date based on chart abstraction, the first cancer-related event was identified with excellent validity (sensitivity, 87.0%; specificity, 93.3%; positive predictive value, 81.5%; negative predictive value, 95.5%). Although administrative data alone did not validly identify cancer-related events, administrative data in combination with chart collected EOIT dates was associated with excellent validity. The collection of EOIT dates by cancer registries would significantly expand the potential of administrative data linkage to assess cancer outcomes.