Sample records for excimer lamp lambda

  1. Difluoro-lambda(5)-phosphinonitrile F(2)P[triple bond]N: matrix isolation and photoisomerization into FP=NF.

    PubMed

    Zeng, Xiaoqing; Beckers, Helmut; Willner, Helge

    2009-01-01

    Splendid isolation: Monomeric phosphazene F(2)PN ((1)A(1)) was prepared for the first time through irradiation of F(2)PN(3) in an argon matrix with an ArF excimer laser (lambda=193 nm). Upon subsequent irradiation with a high-pressure mercury arc lamp (lambda=255 nm), F(2)PN undergoes a 1,2-fluorine shift to give iminophosphane cis-FP=NF.

  2. Improved vacuum-UV (VUV)-initiated photomineralization of organic compounds in water with a xenon excimer flow-through photoreactor (Xe2* lamp, 172 nm) containing an axially centered ceramic oxygenator.

    PubMed

    Oppenländer, Thomas; Walddörfer, Carsten; Burgbacher, Jens; Kiermeier, Martin; Lachner, Klaus; Weinschrott, Helga

    2005-07-01

    Xenon excimer (Xe2*) lamps can be used for the oxidation and mineralization of organic compounds in aqueous solution. This vacuum-ultraviolet (VUV) photochemical method is mainly based on the photochemically initiated homolysis of water that produces hydrogen atoms and hydroxyl radicals. The efficiency of substrate oxidation and mineralization is limited markedly due to the high absorbance of water at the emission maximum of the Xe2* lamp (lambda(max)=172 nm). This photochemical condition generates an extreme heterogeneity between the irradiated volume V(irr) and the non-irradiated ("dark") bulk solution. During VUV-initiated photomineralization of organic substrates, the fast scavenging of hydrogen atoms and of carbon-centered radicals by dissolved molecular oxygen produces a permanent oxygen deficit within V(irr) and adjacent compartments. Hence, at a constant photon flux the concentration of dissolved molecular oxygen within the zones of photo and thermal radical reactions limits the rate of mineralization, i.e. the rate of TOC diminution. Thus, a simple and convenient technique is presented that overcomes this limitation by injection of molecular oxygen (or air) into the irradiated volume by use of a ceramic oxygenator (aerator). The tube oxygenator was centered axially within the xenon excimer flow-through lamp. Consequently, the oxygen or air bubbles enhanced the transfer of dissolved molecular oxygen into the VUV-irradiated volume leading to an increased rate of mineralization of organic model compounds, e.g. 1-heptanol, benzoic acid and potassium hydrogen phthalate.

  3. Treatment of alopecia areata with 308-nm excimer lamp.

    PubMed

    Ohtsuki, Akiko; Hasegawa, Toshio; Ikeda, Shigaku

    2010-12-01

    Alopecia areata is considered to be a T-cell mediated autoimmune disorder. The 308-nm excimer lamp is thought to be capable of inducing T-cell apoptosis in vitro, suggesting that the lamp might be effective for the treatment of alopecia areata. We examined the effectiveness of the 308-nm excimer lamp for the treatment of alopecia areata. We recruited three patients with single alopecia areata lesions that were resistant to conventional treatment. The lesions were exposed to a 308-nm excimer lamp at 2-weekly intervals. Hair regrowth was observed in all three patients after approximately 10 treatment sessions. Our study showed that exposure to the 308-nm excimer lamp effectively induced hair regrowth in solitary alopecia areata lesions. Apart from erythema, there were no significant adverse effects. Therefore, we suggest that it may be considered as a treatment modality for recalcitrant alopecia areata. © 2010 Japanese Dermatological Association.

  4. The excimer lamp induces cutaneous nerve degeneration and reduces scratching in a dry-skin mouse model.

    PubMed

    Kamo, Atsuko; Tominaga, Mitsutoshi; Kamata, Yayoi; Kaneda, Kazuyuki; Ko, Kyi C; Matsuda, Hironori; Kimura, Utako; Ogawa, Hideoki; Takamori, Kenji

    2014-12-01

    Epidermal hyperinnervation, which is thought to underlie intractable pruritus, has been observed in patients with atopic dermatitis (AD). The epidermal expression of axonal guidance molecules has been reported to regulate epidermal hyperinnervation. Previously, we showed that the excimer lamp has antihyperinnervative effects in nonpruritic dry-skin model mice, although epidermal expression of axonal guidance molecules was unchanged. Therefore, we investigated the antipruritic effects of excimer lamp irradiation and its mechanism of action. A single irradiation of AD model mice significantly inhibited itch-related behavior 1 day later, following improvement in the dermatitis score. In addition, irradiation of nerve fibers formed by cultured dorsal root ganglion neurons increased bleb formation and decreased nerve fiber expression of nicotinamide mononucleotide adenylyl transferase 2, suggesting degenerative changes in these fibers. We also analyzed whether attaching a cutoff excimer filter (COF) to the lamp, thus decreasing cytotoxic wavelengths, altered hyperinnervation and the production of cyclobutane pyrimidine dimer (CPD), a DNA damage marker, in dry-skin model mice. Irradiation with COF decreased CPD production in keratinocytes, as well as having an antihyperinnervative effect, indicating that the antipruritic effects of excimer lamp irradiation with COF are due to induction of epidermal nerve degeneration and reduced DNA damage.

  5. Bubble formation during pulsed laser ablation: mechanism and implications

    NASA Astrophysics Data System (ADS)

    van Leeuwen, Ton G. J. M.; Jansen, E. Duco; Motamedi, Massoud; Welch, Ashley J.; Borst, Cornelius

    1993-07-01

    Holmium ((lambda) equals 2.09 micrometers ) and excimer ((lambda) equals 308 nm) lasers are used for ablation of tissue. In a previous study it was demonstrated that both excimer and holmium laser pulses produce fast expanding and collapsing vapor bubbles. To investigate whether the excimer induced bubble is caused by vaporization of water, the threshold fluence for bubble formation at a bare fiber tip in water was compared between the excimer laser (pulse length 115 ns) and the Q-switched and free-running holmium lasers (pulse length 1 microsecond(s) to 250 microsecond(s) , respectively). To induce bubble formation by excimer laser light in water, the absorber oxybuprocaine-hydrochloride (OBP-HCl) was added to the water. Fast flash photography was used to measure the threshold fluence as a function of the water temperature (6 - 90 degree(s)C) at environmental pressure. The ultraviolet excimer laser light is strongly absorbed by blood. Therefore, to document the implications of bubble formation at fluences above the tissue ablation threshold, excimer laser pulses were delivered in vitro in hemoglobin solution and in vivo in the femoral artery of the rabbit. We conclude that the principal content of the fast bubble induced by a 308 nm excimer laser pulse is water vapor. Therefore, delivery of excimer laser pulses in a water or blood environment will cause fast expanding water vapor bubbles, which may induce mechanical damage to adjacent tissue.

  6. Evaluation results for the positive deep-UV resist AZ DX 46

    NASA Astrophysics Data System (ADS)

    Spiess, Walter; Lynch, Thomas J.; Le Cornec, Charles; Escher, Gary C.; Kinoshita, Yoshiaki; Kochan, John; Kudo, Takanori; Masuda, Seiya; Mourier, Thierry; Nozaki, Yuko; Olson, Setha G.; Okazaki, Hiroshi; Padmanaban, Munirathna; Pawlowski, Georg; Przybilla, Klaus J.; Roeschert, Horst; Suehiro, Natusmi; Vinet, Francoise; Wengenroth, Horst

    1994-05-01

    This contribution emphasizes resist application site by communicating lithographic results for AZ DX 46, obtained using the GCA XLS 7800/31 stepper, NA equals 0.53, equipped with krypton fluoride excimer laser ((lambda) equals 248 nm), model 4500 D, as exposure source, delivered by Cymer Laser Technologies. As far as delay time experiments are concerned ASM-L PAS 5500/70 stepper, NA equals 0.42, was used in combination with Lambda Physik excimer laser, model 248 L.

  7. Excimer Laser Curing Of Polymer Coatings

    NASA Astrophysics Data System (ADS)

    Klick, David; Akerman, M. Alfred; Paul, George L.; Supurovic, Darko; Tsuda, Haruki

    1988-12-01

    The use of the excimer laser as a source of energy for photo-assisted curing of industrial polymeric coatings was investigated. Presently, UV lamps are sometimes used to excite a photoinitiating molecule mixed with the starting monomers and oligomers of a coating. The resulting polymeric chain reaction multiplies the effect of the initial photons, making economical use of the light source. The high cost of laser photons may thus be justifiable if lasers provide advantages over lamps. A series of visibly transparent 7 μm coatings (a typical thickness for 'slick' magazine coatings) with various photoinitiators, monomers, and oligomers was illuminated with excimer laser light of various wavelengths, fluences, and pulse repetition rates. For the optimum parameters, it was found that the laser had large advantages in curing speed over existing UV lamp processes, due to its monochromaticity. Pigmented coatings (20 μm TiO2 mixtures typical of appliance or automotive finishes) are not easily cured with UV lamps due to the inability of light to penetrate the absorbing and scattering pigmented layer. However, economically-viable cure rates were achieved with certain photoinitiators using a tunable excimer-pumped dye laser. A prototype of such a laser suitable for factory use was built and used to cure these coatings. Results are scaled to a factory situation, and costs are calculated to show the advantages of the laser method over currently used processes.

  8. Comparative tensile strength study of the adhesion improvement of PTFE by UV photon assisted surface processing

    NASA Astrophysics Data System (ADS)

    Hopp, B.; Geretovszky, Zs.; Bertóti, I.; Boyd, I. W.

    2002-01-01

    Poly(tetrafluoroethylene) (PTFE) is notable for its non-adhesive and non-reactive properties. A number of technologies can potentially benefit from the application of PTFE, but these characteristics restrict the ability to structuring its surface. In this paper, we present results on two ultraviolet photon assisted treatments of PTFE. The originally poor adhesion was significantly improved by both 172 nm excimer lamp and 193 nm excimer laser assisted surface treatments. While Xe2∗ lamp irradiation, applied in a modest vacuum environment, was sufficient by itself to improve adhesion, the ArF laser process was only effective when the irradiated interface was in contact with 1,2-diaminoethane photoreagent. It was found that the tensile strength of an epoxy resin glued interface created on treated surfaces depended strongly on the applied number of laser pulses and lamp irradiation time. Laser treatment caused fast tensile strength increase during the first 50-500 pulses, while after this it saturates slowly at about 5.5 MPa in the 500-2500 pulse domain. The excimer lamp irradiation resulted in a maximum tensile strength of approximately 10 MPa after 2 min irradiation time which reduced to about 65% of the peak value at longer times.

  9. Excimer UV lamp irradiation induced grafting on synthetic polymers

    NASA Astrophysics Data System (ADS)

    Praschak, D.; Bahners, T.; Schollmeyer, E.

    Surface modifications on polyethyleneterephthalate (PET) films following excimer UV lamp irradiation induced grafting were studied. Characteristics of the modifications depending on the conditions during the irradiation were analysed using contact-angle measurements, X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), differential scanning calorimetry (DSC) and Fourier-transform infrared spectroscopy (FTIR). Depending on the conditions during the irradiation different surface modifications were obtained, which can generally be classified regarding the hydrophilic or hydrophobic characteristics of the resulting surface. It is shown that not every substance that meets the general demands will be grafted on synthetic polymers using excimer UV radiation. Examples of agents that can simply be grafted onto polymer surfaces and those that undergo further crosslinking, building up thin films are listed. Agents used for grafting on polymers are 1,5-hexadiene, perfluoro-4-methyl-pent-2-ene, polyethyleneglycol 200, monosilane and polyethylene. The transferability of the effects achieved to substrates such as polyparaphenylene terephthalamide or polymetaphenylene isophthalamide is shown.

  10. 207-nm UV Light-A Promising Tool for Safe Low-Cost Reduction of Surgical Site Infections. II: In-Vivo Safety Studies.

    PubMed

    Buonanno, Manuela; Stanislauskas, Milda; Ponnaiya, Brian; Bigelow, Alan W; Randers-Pehrson, Gerhard; Xu, Yanping; Shuryak, Igor; Smilenov, Lubomir; Owens, David M; Brenner, David J

    2016-01-01

    UVC light generated by conventional germicidal lamps is a well-established anti-microbial modality, effective against both bacteria and viruses. However, it is a human health hazard, being both carcinogenic and cataractogenic. Earlier studies showed that single-wavelength far-UVC light (207 nm) generated by excimer lamps kills bacteria without apparent harm to human skin tissue in vitro. The biophysical explanation is that, due to its extremely short range in biological material, 207 nm UV light cannot penetrate the human stratum corneum (the outer dead-cell skin layer, thickness 5-20 μm) nor even the cytoplasm of individual human cells. By contrast, 207 nm UV light can penetrate bacteria and viruses because these cells are physically much smaller. To test the biophysically-based hypothesis that 207 nm UV light is not cytotoxic to exposed mammalian skin in vivo. Hairless mice were exposed to a bactericidal UV fluence of 157 mJ/cm2 delivered by a filtered Kr-Br excimer lamp producing monoenergetic 207-nm UV light, or delivered by a conventional 254-nm UV germicidal lamp. Sham irradiations constituted the negative control. Eight relevant cellular and molecular damage endpoints including epidermal hyperplasia, pre-mutagenic UV-associated DNA lesions, skin inflammation, and normal cell proliferation and differentiation were evaluated in mice dorsal skin harvested 48 h after UV exposure. While conventional germicidal UV (254 nm) exposure produced significant effects for all the studied skin damage endpoints, the same fluence of 207 nm UV light produced results that were not statistically distinguishable from the zero exposure controls. As predicted by biophysical considerations and in agreement with earlier in vitro studies, 207-nm light does not appear to be significantly cytotoxic to mouse skin. These results suggest that excimer-based far-UVC light could potentially be used for its anti-microbial properties, but without the associated hazards to skin of conventional germicidal UV lamps.

  11. 207-nm UV Light—A Promising Tool for Safe Low-Cost Reduction of Surgical Site Infections. II: In-Vivo Safety Studies

    PubMed Central

    Buonanno, Manuela; Stanislauskas, Milda; Ponnaiya, Brian; Bigelow, Alan W.; Randers-Pehrson, Gerhard; Xu, Yanping; Shuryak, Igor; Smilenov, Lubomir; Owens, David M.; Brenner, David J.

    2016-01-01

    Background UVC light generated by conventional germicidal lamps is a well-established anti-microbial modality, effective against both bacteria and viruses. However, it is a human health hazard, being both carcinogenic and cataractogenic. Earlier studies showed that single-wavelength far-UVC light (207 nm) generated by excimer lamps kills bacteria without apparent harm to human skin tissue in vitro. The biophysical explanation is that, due to its extremely short range in biological material, 207 nm UV light cannot penetrate the human stratum corneum (the outer dead-cell skin layer, thickness 5–20 μm) nor even the cytoplasm of individual human cells. By contrast, 207 nm UV light can penetrate bacteria and viruses because these cells are physically much smaller. Aims To test the biophysically-based hypothesis that 207 nm UV light is not cytotoxic to exposed mammalian skin in vivo. Methods Hairless mice were exposed to a bactericidal UV fluence of 157 mJ/cm2 delivered by a filtered Kr-Br excimer lamp producing monoenergetic 207-nm UV light, or delivered by a conventional 254-nm UV germicidal lamp. Sham irradiations constituted the negative control. Eight relevant cellular and molecular damage endpoints including epidermal hyperplasia, pre-mutagenic UV-associated DNA lesions, skin inflammation, and normal cell proliferation and differentiation were evaluated in mice dorsal skin harvested 48 h after UV exposure. Results While conventional germicidal UV (254 nm) exposure produced significant effects for all the studied skin damage endpoints, the same fluence of 207 nm UV light produced results that were not statistically distinguishable from the zero exposure controls. Conclusions As predicted by biophysical considerations and in agreement with earlier in vitro studies, 207-nm light does not appear to be significantly cytotoxic to mouse skin. These results suggest that excimer-based far-UVC light could potentially be used for its anti-microbial properties, but without the associated hazards to skin of conventional germicidal UV lamps. PMID:27275949

  12. Microwave discharge electrodeless lamps (MDEL). V. Microwave-assisted photolytic disinfection of Bacillus subtilis in simulated electroplating wash wastewaters.

    PubMed

    Horikoshi, Satoshi; Tsuchida, Akihiro; Abe, Masahiko; Ohba, Naoki; Uchida, Masayoshi; Serpone, Nick

    2010-01-01

    This short article examines the microwave-assisted photolytic disinfection of aqueous solutions contaminated by Bacillus subtilis microorganisms using UV and vacuum-UV radiation emitted from a microwave discharge electrodeless lamp (MDEL), a device containing a Hg/Ar gas-fill that was proposed recently for use in Advanced Oxidation Processes (AOPs). Results of the disinfection are compared with those obtained from UV radiation emitted by a low-pressure electrode Hg lamp and by an excimer lamp. Also examined is the disinfection of B. subtilis aqueous media that contained Au3+ or Ni2+ ions, species often found in the treatment of electroplating wash wastewaters.

  13. Engineering of a highly efficient Xe₂*-excilamp (xenon excimer lamp, λmax=172 nm, η=40%) and qualitative comparison to a low-pressure mercury lamp (LP-Hg, λ=185/254 nm) for water purification.

    PubMed

    Al-Gharabli, Samer; Engeßer, Patrick; Gera, Diana; Klein, Sandra; Oppenländer, Thomas

    2016-02-01

    Excilamps are mercury-free gas-discharge sources of non-coherent VUV or UV radiation with high radiant power and a long lifetime. The most efficient excilamp that is currently available on the market is a VUV xenon excilamp system (Xe2(*)-excimer lamp, λ(max) = 172 nm) with a stated radiant efficiency η of 40% at an electrical input power P(el) of 20 W, 50 W or 100 W. In this paper, the use of this highly efficient Xe2(*)-excilamp (P(el) = 20 W) for water treatment is demonstrated using a recirculating laboratory photoreactor system with negative radiation geometry. The efficiency in the 172 nm initiated bleaching of aqueous solutions of Rhodamine B is compared to that initiated by a common low-pressure mercury (LP-Hg) lamp (185 nm, TNN 15/32). The dependence of the pseudo zero order rate constant k´ of decolorization of RhB on the flow rate and on the initial concentration of RhB was investigated. Both lamps exhibited dependences of k´ on the initial concentration of RhB, which represents a typical saturation kinetical behavior. The saturation kinetics was very prominent in the case of the Xe2(*)-excilamp. Also, the Xe2(*)-excilamp treatment exhibited a significant influence on the flow rate of the RhB aqueous solution, which was not the case during the LP-Hg lamp initiated bleaching of RhB. The results of this paper demonstrate that Xe2(*)-excilamps can be used for VUV-initiated water purification. However, to reach the maximum efficacy of the Xe2(*)-excilamp for photo-initiated water purification further engineering optimization of the photoreactor concept is necessary. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Development of fibrin-free intraocular lens with photochemical surface modification

    NASA Astrophysics Data System (ADS)

    Sato, Yuji; Tanizawa, Katsuya; Anai, Hiroyuki; Sato, Nobuhiro; Sato, Yuki; Ajiki, Tooru; Parel, Jean-Marie; Murahara, Masataka

    2004-07-01

    Having substituted the hydrophilic and hydrophobic groups alternately on the soft acrylic resin intraocular lens (IOL) surface by using an ArF excimer laser and a Xe2 excimer lamp, we have developed the IOL that is free from fibrin. Acrylic resin or PMMA lens has been used as an intraocular lens for 50 years. However, protein and fat are stuck onto the IOL surface after a long implantation, which opacifies the surface (after-cataract). Thus, we designed the micro domain structures of hydrophilic and hydrophobic groups on the IOL surface for fibrin-free. Firstly, the IOL was irradiated with the Xe2 excimer lamp in the presence of perfluoropolyether in order to make it hydrophobic. By this photochemical reaction, the CF3 functional groups were substituted on the IOL surface. Secondly, the ArF laser was projected on the IOL through the mask pattern in reduced size in the presence of water in order to be hydrophilic. With the photochemical reaction, the OH groups were substituted at the part exposed. The fibrin adsorption test of the modified IOL surface was carried out with FT-IR; which revealed that the fibrin-sticking rate of the treated sample has decreased by 23% compared with that of the non-treated sample. As a result, the fibrin-free IOL has been made by modifying the surface of the IOL to have the micro domain structures of the hydrophilic and hydrophobic groups that are arrayed alternately. In conclusion, the ideal intraocular lens has been demonstrated.

  15. Experimental ultraviolet photocarcinogenesis: wavelength interactions and time-dose relationships.

    PubMed

    Forbes, P D; Davies, R E; Urbach, F

    1978-12-01

    Tumors were induced in the skin of SKH hairless mice by exposure to fluorescent FS sun lamps or to a long-arc xenon solar simulator. Tumores developed about equally well with varying amounts of UV-A radiation (lambda greater than 320 nm) given simultaneously. In contrast, incremental changes in the UV-B region (lambda less than 320 nm) led to substantial increases in carcinogenic effectiveness. A tumor-"initiating" dose of UV-B (4-10 wk of daily FS lamp exposures) was rendered less effective by subsequent exposures of the mice to UV-A (6 hr/day, F-40 T12BL lamps). The mechanism for this effect is not known. Most tumors induced by a short course (10 wk) of FS lamp exposure grew slowly or regressed, whereas mice exposed for a longer period (30 wk) developed more tumors, and many of those that appeared early grew aggressively. Effects of daily dose fractionation were less clear, and the subject requires further study. These and other variables are being tested in a program designed to yield useful information on the effects of changing spectrum, dose, and dose delivery rates on sunlight-induced cancer.

  16. Electrical and chemical properties of XeCl*(308 nm) exciplex lamp created by a dielectric barrier discharge

    NASA Astrophysics Data System (ADS)

    Baadj, S.; Harrache, Z.; Belasri, A.

    2013-12-01

    The aim of this work is to highlight, through numerical modeling, the chemical and the electrical characteristics of xenon chloride mixture in XeCl* (308 nm) excimer lamp created by a dielectric barrier discharge. A temporal model, based on the Xe/Cl2 mixture chemistry, the circuit and the Boltzmann equations, is constructed. The effects of operating voltage, Cl2 percentage in the Xe/Cl2 gas mixture, dielectric capacitance, as well as gas pressure on the 308-nm photon generation, under typical experimental operating conditions, have been investigated and discussed. The importance of charged and excited species, including the major electronic and ionic processes, is also demonstrated. The present calculations show clearly that the model predicts the optimal operating conditions and describes the electrical and chemical properties of the XeCl* exciplex lamp.

  17. Ozone Measurements with the US EPA UV-DIAL: Preliminary Results

    NASA Technical Reports Server (NTRS)

    Moosmueller, H.; Diebel, D.; Bundy, D. H.; Bristow, M. P.; Alvarez, R. J., II; Kovalev, V. A.; Edmonds, C. M.; Turner, R. M.; Mcelroy, J. L.

    1992-01-01

    A compact airborne down-looking lidar system was developed at the Environmental Protection Agency in Las Vegas. This differential absorption lidar (DIAL) was designed to simultaneously measure range-resolved concentrations of ozone (O3) and sulfur dioxide (SO2) in the lower troposphere, together with an indication of the aerosol distribution. The five laser wavelengths (i.e., lambda(sub 1) = 277 nm, lambda(sub 2) = 292 nm, lambda(sub 3) = 313 nm, lambda(sub4) = 319 nm, lambda(sub 5) = 369 nm) were generated via Raman conversion of a focused KrF excimer laser. The system is currently installed in a truck-based mobile laboratory. For the ground testing, an opening in the truck floor together with a folding mirror under the truck makes a horizontal, or upwardly inclined direction of measurement possible. Initial ground testing has been performed in the vicinity of a Desert Research Institute (DRI) ambient air monitoring site, located at Cottonwood Cove approximately 85 km south east of Las Vegas, Nevada. At this site O3 and SO2 concentrations are continuously monitored with an average accuracy better than +/- 10 percent. A temporary ozone measurement station with identical accuracy was set up at a distance to get a second point of comparison for the range-resolved DIAL measurements.

  18. Electrical and chemical properties of XeCl*(308 nm) exciplex lamp created by a dielectric barrier discharge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baadj, S.; Harrache, Z., E-mail: zharrache@yahoo.com; Belasri, A.

    2013-12-15

    The aim of this work is to highlight, through numerical modeling, the chemical and the electrical characteristics of xenon chloride mixture in XeCl* (308 nm) excimer lamp created by a dielectric barrier discharge. A temporal model, based on the Xe/Cl{sub 2} mixture chemistry, the circuit and the Boltzmann equations, is constructed. The effects of operating voltage, Cl{sub 2} percentage in the Xe/Cl{sub 2} gas mixture, dielectric capacitance, as well as gas pressure on the 308-nm photon generation, under typical experimental operating conditions, have been investigated and discussed. The importance of charged and excited species, including the major electronic and ionicmore » processes, is also demonstrated. The present calculations show clearly that the model predicts the optimal operating conditions and describes the electrical and chemical properties of the XeCl* exciplex lamp.« less

  19. Challenges of UV light processing of low UVT foods and beverages

    NASA Astrophysics Data System (ADS)

    Koutchma, Tatiana

    2010-08-01

    Ultraviolet (UV) technology holds promise as a low cost non-thermal alternative to heat pasteurization of liquid foods and beverages. However, its application for foods is still limited due to low UV transmittance (LUVT). LUVT foods have a diverse range of chemical (pH, Brix, Aw), physical (density and viscosity) and optical properties (absorbance and scattering) that are critical for systems and process designs. The commercially available UV sources tested for foods include low and medium pressure mercury lamps (LPM and MPM), excimer and pulsed lamps (PUV). The LPM and excimer lamps are monochromatic sources whereas emission of MPM and PUV is polychromatic. The optimized design of UV-systems and UV-sources with parameters that match to specific product spectra have a potential to make UV treatments of LUVT foods more effective and will serve its further commercialization. In order to select UV source for specific food application, processing effects on nutritional, quality, sensorial and safety markers have to be evaluated. This paper will review current status of UV technology for food processing along with regulatory requirements. Discussion of approaches and results of measurements of chemico-physical and optical properties of various foods (fresh juices, milk, liquid whey proteins and sweeteners) that are critical for UV process and systems design will follow. Available UV sources did not prove totally effective either resulting in low microbial reduction or UV over-dosing of the product thereby leading to sensory changes. Beam shaping of UV light presents new opportunities to improve dosage uniformity and delivery of UV photons in LUVT foods.

  20. Effects of wavelength and water quality on photodegradation of N-Nitrosodimethylamine (NDMA).

    PubMed

    Sakai, Hiroshi; Takamatsu, Tatsuro; Kosaka, Koji; Kamiko, Naoyuki; Takizawa, Satoshi

    2012-10-01

    N-Nitrosodimethylamine (NDMA) is a potent carcinogen that yields a cancer risk of 10(-6) at concentrations as low as 0.7 ng L(-1). Tentative guideline values are set at 3 ng L(-1) in California, USA; 9 ng L(-1) in Ontario, Canada; 40 ng L(-1) nationwide in Canada; and 100 ng L(-1) by the World Health Organization. NDMA is a great concern in treating reclaimed water as well as drinking water. UV degradation can be considered effective degradation method. A 1-log reduction of NDMA is achieved by 1000 mJ cm(-2) of a 254-nm low pressure (LP) mercury UV lamp. However, a higher degradation efficiency than that provided by LP lamps is desired in practical treatment. In this study, the effects of wavelength and water quality were investigated to achieve higher degradation efficiency. The effects of wavelength were examined by comparing three UV lamps: a 222-nm Kr Cl Excimer UV lamp, a 254-nm LP mercury UV lamp, and a 230- to 270-nm filtered medium pressure (FMP) mercury UV lamp. The 222-nm lamp and FMP lamp achieved 4 times and 2.8 times higher degradation efficiency, respectively, than the conventional 254-nm LP lamp. Effects on water quality were also simulated by using absorption spectrum data of nitrate solutions and process water from a drinking-water treatment plant. In the simulation, the 222-nm lamp was affected by UV-absorbing compounds in the water, whereas the FMP lamp showed more stable degradation efficiency. Appropriate use of these three types of lamps could enhance the efficiency of degradation of NDMA. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. LASER APPLICATIONS AND OTHER TOPICS IN QUANTUM ELECTRONICS: On the possibility of pumping Xe2* lasers and VUV lamps in the afterglow of a background-electron multiplication wave

    NASA Astrophysics Data System (ADS)

    Boichenko, Aleksandr M.; Yakovlenko, Sergei I.

    2006-12-01

    It was shown earlier that the ionisation propagation in a gas at about the atmospheric pressure may proceed due to the multiplication of the existing electrons with a low background density rather than the transfer of electrons or photons. We consider the feasibility of using the plasma produced in the afterglow of this background-electron multiplication wave for pumping plasma lasers (in particular, Xe2* xenon excimer lasers) as well as excilamps. Simulations show that it is possible to achieve the laser effect at λapprox172 nm as well as to substantially improve the peak specific power of the spontaneous radiation of xenon lamps.

  2. Photochemical removal of NO(2) by using 172-nm Xe(2) excimer lamp in N(2) or air at atmospheric pressure.

    PubMed

    Tsuji, Masaharu; Kawahara, Masashi; Noda, Kenji; Senda, Makoto; Sako, Hiroshi; Kamo, Naohiro; Kawahara, Takashi; Kamarudin, Khairul Sozana Nor

    2009-03-15

    Photochemical removal of NO(2) in N(2) or air (5-20% O(2)) mixtures was studied by using 172-nm Xe(2) excimer lamps to develop a new simple photochemical aftertreatment technique of NO(2) in air at atmospheric pressure without using any catalysts. When a high power lamp (300 mW/cm(2)) was used, the conversion of NO(2) (200-1000 ppm) to N(2) and O(2) in N(2) was >93% after 1 min irradiation, whereas that to N(2)O(5), HNO(3), N(2), and O(2) in air (10% O(2)) was 100% after 5s irradiation in a batch system. In a flow system, about 92% of NO(2) (200 ppm) in N(2) was converted to N(2) and O(2), whereas NO(2) (200-400 ppm) in air (20% O(2)) could be completely converted to N(2)O(5), HNO(3), N(2), and O(2) at a flow rate of 1l/min. It was found that NO could also be decomposed to N(2) and O(2) under 172-nm irradiation, though the removal rate is slower than that of NO(2) by a factor of 3.8. A simple model analysis assuming a consecutive reaction NO(2)-->NO-->N+O indicated that 86% of NO(2) is decomposed directly into N+O(2) and the rest is dissociated into NO+O under 172-nm irradiation. These results led us to conclude that the present technique is a new promising catalyst-free photochemical aftertreatment method of NO(2) in N(2) and air in a flow system.

  3. Collisional and radiative processes in high-pressure discharge plasmas

    NASA Astrophysics Data System (ADS)

    Becker, Kurt H.; Kurunczi, Peter F.; Schoenbach, Karl H.

    2002-05-01

    Discharge plasmas at high pressures (up to and exceeding atmospheric pressure), where single collision conditions no longer prevail, provide a fertile environment for the experimental study of collisions and radiative processes dominated by (i) step-wise processes, i.e., the excitation of an already excited atomic/molecular state and by (ii) three-body collisions leading, for instance, to the formation of excimers. The dominance of collisional and radiative processes beyond binary collisions involving ground-state atoms and molecules in such environments allows for many interesting applications of high-pressure plasmas such as high power lasers, opening switches, novel plasma processing applications and sputtering, absorbers and reflectors for electromagnetic waves, remediation of pollutants and waste streams, and excimer lamps and other noncoherent vacuum-ultraviolet light sources. Here recent progress is summarized in the use of hollow cathode discharge devices with hole dimensions in the range 0.1-0.5 mm for the generation of vacuum-ultraviolet light.

  4. Water Treatment Using Advanced Ultraviolet Light Sources Final Report CRADA No. TC02089.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoppes, W.; Oster, S.

    This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Teknichal Services, LLC (TkS), to develop water treatment systems using advanced ultraviolet light sources. The Russian institutes involved with this project were The High Current Electronics Institute (HCEI) and Russian Institute of Technical Physics-Institute of Experimental Physics (VNIIEF). HCEI and VNIIEF developed and demonstrated the potential commercial viability of short-wavelength ultraviolet excimer lamps under a Thrust 1 Initiatives for Proliferation Prevention (IPP) Program. The goals of this collaboration were to demonstrate both the commercial viability of excilampbased watermore » disinfection and achieve further substantial operational improvement in the lamps themselves; particularly in the area of energy efficiency.« less

  5. Evaluation of the Applicability of Solar and Lamp Radiometric Calibrations of a Precision Sun Photometer Operating Between 300 and 1025 nm

    NASA Technical Reports Server (NTRS)

    Schmid, Beat; Spyak, Paul R.; Biggar, Stuart F.; Joerg, Sekler; Ingold, Thomas; Maetzler, Christian; Kaempfer, Niklaus

    2000-01-01

    Over a period of 3 year a precision Sun photometer (SPM) operating between 300 and 1025 nm was calibrated four times at three different high-mountain sites in Switzerland, Germany, and the United States by means of the Langley-plot technique. We found that for atmospheric window wavelengths the total error (2 sigma-statistical plus systematic errors) of the calibration constants V(sub 0)(lambda), the SPM voltage in the absence of any attenuating atmosphere, can be kept below 1.60% in the UV-A and blue, 0.9% in the mid-visible, and 0.6% in the near-infra red spectral region. For SPM channels within strong water-vapor or ozone absorption bands a modified Langley-plot technique was used to determine V(sub 0)(lambda) with a lower accuracy. Within the same period of time, we calibrated the SPM five times using irradiance standard lamps in the optical labs of the Physikalisch-Meteorologisches Observatorium Davos and World Radiation Center, Switzerland, and of the Remote Sensing Group of the Optical Sciences Center, University of Arizona, Tucson, Arizona. The lab calibration method requires knowledge of the extraterrestrial spectral irradiance. When we refer the standard lamp results to the World Radiation Center extraterrestrial solar irradiance spectrum, they agree with the Langley results within 2% at 6 or 13 SPM wavelengths. The largest disagreement (4.4%) is found for the channel centered at 610 nm. The results of these intercomparisons change significantly when the lamp results are referred to two different extraterrestrial solar irradiance spectra that have become recently available.

  6. Difluorophosphoryl nitrene F2P(O)N: matrix isolation and unexpected rearrangement to F2PNO.

    PubMed

    Zeng, Xiaoqing; Beckers, Helmut; Willner, Helge; Neuhaus, Patrik; Grote, Dirk; Sander, Wolfram

    2009-12-14

    Triplet difluorophosphoryl nitrene F(2)P(O)N (X(3)A'') was generated on ArF excimer laser irradiation (lambda=193 nm) of F(2)P(O)N(3) in solid argon matrix at 16 K, and characterized by its matrix IR, UV/Vis, and EPR spectra, in combination with DFT and CBS-QB3 calculations. On visible light irradiation (lambda>420 nm) at 16 K F(2)P(O)N reacts with molecular nitrogen and some of the azide is regenerated. UV irradiation (lambda=255 nm) of F(2)P(O)N (X(3)A'') induced a Curtius-type rearrangement, but instead of a 1,3-fluorine shift, nitrogen migration to give F(2)PON is proposed to be the first step of the photoisomerization of F(2)P(O)N into F(2)PNO (difluoronitrosophosphine). Formation of novel F(2)PNO was confirmed with (15)N- and (18)O-enriched isotopomers by IR spectroscopy and DFT calculations. Theoretical calculations predict a rather long P-N bond of 1.922 A [B3LYP/6-311+G(3df)] and low bond-dissociation energy of 76.3 kJ mol(-1) (CBS-QB3) for F(2)PNO.

  7. (E)-5-[2-(methoxycarbonyl)ethenyl]cytidine as a chemical actinometer for germicidal UV radiation.

    PubMed

    Shen, Chengyue; Fang, Shiyue; Bergstrom, Donald E; Blatchley, Ernest R

    2005-05-15

    (E)-5-[2-(Methoxycarbonyl)ethenyl]cytidine (S) was examined for use as a chemical actinometer for germicidal UV radiation. Its photoproduct, 3-beta-D-ribofuranosyl-2,7-dioxopyrido[2,3-d]pyrimidine (P), is strongly fluorescent with excitation and emission maxima at 330 and 385 nm, respectively. Experiments were conducted to characterize the dynamic behavior of aqueous solutions of S and P when subjected to UV radiation. UV sources used for these experiments included a low-pressure mercury lamp, a XeBr excimer lamp, and a KrCI excimer lamp; all three sources were mounted in collimating devices to provide incident beams that could be easily and accurately characterized by radiometry. These three sources each yielded essentially monochromatic outputwith characteristic wavelengths of 254, 282, and 222 nm, respectively. At practical concentrations, it was found that the absorbance of the actinometer solution was neither high enough to make the actinometer solutions optically opaque nor low enough to be optically transparent to UV. In addition, the photoproduct displayed a molar absorption coefficient that was similar in magnitude to that of the parent compound, thereby resulting in competitive absorption of UV energy between Sand Pduring irradiation. For purposes of evaluation of the results of irradiation, a mathematical model was developed to accountforthe nonideal optical characteristics of the system. The model is based on a description of local photochemical kinetics; predictions of overall reactor performance were developed by spatial and temporal integration of model results. The model was used to analyze the dynamic behavior of actinometer solutions during UV irradiation and to estimate the quantum yield for photoproduction of Pfrom S. This modeling approach is potentially applicable to other photochemical processes in which multiple compounds are present that absorb photoactive radiation; however, general application of this modeling approach to photochemical reactor systems will require inclusion of othertermsto describe relevanttransport behavior within the system.

  8. Corneal reshaping using a pulsed UV solid-state laser

    NASA Astrophysics Data System (ADS)

    Ren, Qiushi; Simon, Gabriel; Parel, Jean-Marie A.; Shen, Jin-Hui; Takesue, Yoshiko

    1993-06-01

    Replacing the gas ArF (193 nm) excimer laser with a solid state laser source in the far-UV spectrum region would eliminate the hazards of a gas laser and would reduce its size which is desirable for photo-refractive keratectomy (PRK). In this study, we investigated corneal reshaping using a frequency-quintupled (213 nm) pulsed (10 ns) Nd:YAG laser coupled to a computer-controlled optical scanning delivery system. Corneal topographic measurements showed myopic corrections ranging from 2.3 to 6.1 diopters. Post-operative examination with the slit-lamp and operating microscope demonstrated a smoothly ablated surface without corneal haze. Histological results showed a smoothly sloping surface without recognizable steps. The surface quality and cellular effects were similar to that of previously described excimer PRK. Our study demonstrated that a UV solid state laser coupled to an optical scanning delivery system is capable of reshaping the corneal surface with the advantage of producing customized, aspheric corrections without corneal haze which may improve the quality of vision following PRK.

  9. Production of reactive species using vacuum ultraviolet photodissociation as a tool for studying their effects in plasma medicine: simulations and measurements

    NASA Astrophysics Data System (ADS)

    Ono, Ryo; Tokumitsu, Yusuke; Zen, Shungo; Yonemori, Seiya

    2014-11-01

    We propose a method for producing OH, H, O, O3, and O2(a1Δg) using the vacuum ultraviolet photodissociation of H2O and O2 as a tool for studying the reaction processes of plasma medicine. For photodissociation, an H2O/He or O2/He mixture flowing in a quartz tube is irradiated by a Xe2 or Kr2 excimer lamp. The effluent can be applied to a target. Simulations show that the Xe2 lamp method can produce OH radicals within 0.1-1 ppm in the effluent at 5 mm from a quartz tube nozzle. This is comparable to those produced by a helium atmospheric-pressure plasma jet (He-APPJ) currently used in plasma medicine. The Xe2 lamp method also produces H atoms of, at most, 6 ppm. In contrast, the maximum O densities produced by the Xe2 and Kr2 lamp methods are 0.15 ppm and 2.5 ppm, respectively; these are much lower than those from He-APPJ (several tens of ppm). Both lamp methods can produce ozone at concentrations above 1000 ppm and O2(a1Δg) at tens of ppm. The validity of the simulations is verified by measuring the O3 and OH densities produced by the Xe2 lamp method using ultraviolet absorption and laser-induced fluorescence. The differences between the measured and simulated densities for O3 and OH are 20% and factors of 3-4, respectively.

  10. Investigation of the development of dielectric-barrier discharge instabilities in excimer lamp

    NASA Astrophysics Data System (ADS)

    Bouchachia, A.; Belasri, A.; Harrache, Z.; Amir Aid, D.

    2017-11-01

    This work represents a study of the formation and propagation of the streamer during a pulse in a plasma cell with dielectric barriers containing a Ne/Xe gas mixture. It is based on a longitudinal mono-dimensional model of the dielectric barrier discharge. In this model, we show the possibility of streamers development in the cathode sheath and its propagation during the plasma formation stage. The model gives the spatiotemporal variations of the propagation speed, the electric field, and the charged particle density of the streamer's head.

  11. Phenomenon of period-doubling in holographic periodic structures exposed to UV radiation

    NASA Astrophysics Data System (ADS)

    Gulyaev, Sergey N.; Isaev, Igor V.

    2001-02-01

    This paper presents the experimental study of the period- doubling phenomenon occurring during the multi-cycle processing procedure incorporating the exposure of Ag halide photoemulsion with the primary recorded holographic structure to the short-wave UV radiation, washing and drying. It is suggested that the simultaneous presence of two contrary photochemical processes -- photodecomposition and radiation hardening in the gelatin results in instability of the primary holographic structure and in the formation of the spatial subharmonic of the surface relief. The phenomenon may be considered as a process of the self-organization initiated by instability of the macrostructure on a rearrangement of the microstructure on the molecule level. The period-doubling phenomenon has been found to occur in the experiments with the UV sources of a various spectral composition -- the mercury- vapor lamp and the excimer lamps operating on the mixtures of Xe+Cl2 and Kr+Cl2.

  12. [Therapeutic excimer laser treatment of the cornea].

    PubMed

    Linke, S J; Steinberg, J; Katz, T

    2013-06-01

    Concomitant with new innovations in the field of refractive surgery, therapeutic excimer laser applications like phototherapeutic keratectomy (PTK) and topography-guided customised ablation treatment are gaining high importance and undergoing rapid evolution. Nowadays, PTK is an effective treatment modality for superficial corneal pathologies. Primary indications are decreased epithelial adherence, superficial opacifications and an irregular corneal surface. For the right indication and successful treatment of corneal pathologies with PTK, a knowledge of the size, depth and nature of the pathology, as well as the refractive status of both eyes is important. Next to slit-lamp examination, objective measuring systems like the topography, confocal microscopy and the anterior segment OCT facilitate presurgical planning. Regarding the treatment procedure the surgeon can choose between a variety of methods. PTK can be combined with manual epithelial debridement or done by only using the excimer laser. In the case of an irregular corneal surface, depending on the pathology, masking fluids or topography-guided custom ablation protocols can increase the visual outcome. To avoid recurrence of the underlying pathology (e.g., corneal dystrophy, haze), the topical application of 0.02% mitomycin C for 20-60 seconds has proved to be a safe and effective procedure. If the surgeon considers all the patient-related factors carefully and manages to combine the available treatment options correctly, PTK embodies an effective and minimally invasive alternative to lamellar or penetrating keratoplasty. Georg Thieme Verlag KG Stuttgart · New York.

  13. Modeling of a Ne/Xe dielectric barrier discharge excilamp for improvement of VUV radiation production

    NASA Astrophysics Data System (ADS)

    Khodja, K.; Belasri, A.; Loukil, H.

    2017-08-01

    This work is devoted to excimer lamp efficiency optimization by using a homogenous discharge model of a dielectric barrier discharge in a Ne-Xe mixture. The model includes the plasma chemistry, electrical circuit, and Boltzmann equation. In this paper, we are particularly interested in the electrical and kinetic properties and light output generated by the DBD. Xenon is chosen for its high luminescence in the range of vacuum UV radiation around 173 nm. Our study is motivated by interest in this type of discharge in many industrial applications, including the achievement of high light output lamps. In this work, we used an applied sinusoidal voltage, frequency, gas pressure, and concentration in the ranges of 2-8 kV, 10-200 kHz, 100-800 Torr, and 10-50%, respectively. The analyzed results concern the voltage V p across the gap, the dielectric voltage V d, the discharge current I, and the particles densities. We also investigated the effect of the electric parameters and xenon concentration on the lamp efficiency. This investigation will allow one to find out the appropriate parameters for Ne/Xe DBD excilamps to improve their efficiency.

  14. Photodegradation of lambda-cyhalothrin and cypermethrin in aqueous solution as affected by humic acid and/or copper: intermediates and degradation pathways.

    PubMed

    Xie, Jimin; Wang, Pingli; Liu, Jun; Lv, Xiaomeng; Jiang, Deli; Sun, Cheng

    2011-11-01

    The influence of coexisting humic acids (HA) or Cu²⁺ on the photodegradation of pesticides lambda-cyhalothrin (λ-CHT) and cypermethrin (CPM) in aqueous solution was studied under xenon lamp irradiation. The removal efficiency of pesticides λ-CHT and CPM were enhanced in the presence of either Cu²⁺ or HA but restrained in the presence of both Cu²⁺ and HA. The photodegradation of λ-CHT and CPM followed first-order reaction kinetics. The photodegradation intermediates of λ-CHT and CPM were determined using gas chromatography/mass spectrometry. Possible photodegradation pathways included decarboxylation, ester bond cleavage, dechlorination, and phenyl group removal. Copyright © 2011 SETAC.

  15. Improved Performance of Loop-Mediated Isothermal Amplification Assays via Swarm Priming.

    PubMed

    Martineau, Rhett L; Murray, Sarah A; Ci, Shufang; Gao, Weimin; Chao, Shih-Hui; Meldrum, Deirdre R

    2017-01-03

    This work describes an enhancement to the loop-mediated isothermal amplification (LAMP) reaction which results in improved performance. Enhancement is achieved by adding a new set of primers to conventional LAMP reactions. These primers are termed "swarm primers" based on their relatively high concentration and their ability to create new amplicons despite the theoretical lack of single-stranded annealing sites. The primers target a region upstream of the FIP/BIP primer recognition sequences on opposite strands, substantially overlapping F1/B1 sites. Thus, despite the addition of a new primer set to an already complex assay, no significant increase in assay complexity is incurred. Swarm priming is presented for three DNA templates: Lambda phage, Synechocystis sp. PCC 6803 rbcL gene, and human HFE. The results of adding swarm primers to conventional LAMP reactions include increased amplification speed, increased indicator contrast, and increased reaction products. For at least one template, minor improvements in assay repeatability are also shown. In addition, swarm priming is shown to be effective at increasing the reaction speed for RNA amplification via RT-LAMP. Collectively, these results suggest that the addition of swarm primers will likely benefit most if not all existing LAMP assays based on state-of-the-art, six-primer reactions.

  16. Photochemically induced deposition of protective alumina coatings onto UV emitting phosphors for Xe excimer discharge lamps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Broxtermann, Mike, E-mail: mike.b@fh-muenster.de; Jüstel, Thomas, E-mail: tj@fh-muenster.de

    2016-08-15

    Highlights: • A UV-reactor for the pH induced precipitation of inorganic material is described. • The photolysis of Azide (N{sub 3}{sup −}) leads to a steady pH increase used for precipitation. • A UV induced Al(OH){sub 3} precipitation is used to craft Al{sub 2}O{sub 3} coatings onto YPO{sub 4}:Bi. • The influence of Al{sub 2}O{sub 3} coated onto YPO{sub 4}:Bi with different thicknesses is discussed. • SEM, VUV-spectroscopy and ESA measurements were performed on Al{sub 2}O{sub 3} coated samples. - Abstract: This work concerns the particle coating of the UV-C emitting phosphor YPO{sub 4}:Bi, targeting a stability enhancement of themore » phosphor material for Xe excimer lamp operation. To this end, the material is coated by the wide band gap material Al{sub 2}O{sub 3}. In order to obtain a thin and homogeneous coating layer, a novel process based on the photochemical cleavage of NaN{sub 3} in water was developed. This results in a slow and continuous enhancement of the pH value due to ongoing NaOH formation, which results in the precipitation of Al(OH){sub 3} from an Al{sub 2}(SO{sub 4}){sub 3} {sub ×} 18H{sub 2}O solution. It turned out that the obtained particle coatings are of much better quality, i.e. homogeneity, compared to coatings made from a wet-chemical homogeneous precipitation process. The morphology and electrochemical properties of Al{sub 2}O{sub 3} coated YPO{sub 4}:Bi are discussed on the basis of optical spectroscopy, ESA measurements, and SEM/EDX investigations.« less

  17. New stable perfluoroallyl radical from perfluoro-2,4-dimethyl-3-ethylpentene-2 and its photoconversion reactions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shvedova, M.K.; Allayarov, S.R.; Barkalov, I.M.

    1988-05-01

    The thermally and chemically stable perfluoroally radical is formed in the radiolysis of perfluoro-2, 4-dimethyl-3-ethylpentene-2. A phototransformation of this radical into other radicals takes place under the action of UV light (/lambda/ < 300 nm) which are thermally unstable. Samples containing up to 90% FMP and 10% of its isomers were placed into ampules made of quartz or SK-4B glass, which gave to EPR signal after irradiation; the ampules were evacuated to a pressure of 0.13 Pa, frozen to 77 K, and irradiated with /sup 60/Co /lambda/-quanta at 77 K with doses up to 200 kGy. Irradiation with UV lightmore » was performed at 77 K with light from a DRSh-1000 lamp.« less

  18. Optical CAD Utilization for the Design and Testing of a LED Streetlamp.

    PubMed

    Jafrancesco, David; Mercatelli, Luca; Fontani, Daniela; Sansoni, Paola

    2017-08-24

    The design and testing of LED lamps are vital steps toward broader use of LED lighting for outdoor illumination and traffic signalling. The characteristics of LED sources, in combination with the need to limit light pollution and power consumption, require a precise optical design. In particular, in every step of the process, it is important to closely compare theoretical or simulated results with measured data (obtained from a prototype). This work examines the various possibilities for using an optical CAD (Lambda Research TracePro ) to design and check a LED lamp for outdoor use. This analysis includes the simulations and testing on a prototype as an example; data acquired by measurement are inserted into the same simulation software, making it easy to compare theoretical and actual results.

  19. Tuning of gold nanoclusters sensing applications with bovine serum albumin and bromelain for detection of Hg2+ ion and lambda-cyhalothrin via fluorescence turn-off and on mechanisms.

    PubMed

    Bhamore, Jigna R; Jha, Sanjay; Basu, Hirakendu; Singhal, Rakesh Kumar; Murthy, Z V P; Kailasa, Suresh Kumar

    2018-04-01

    Herein, fluorescent gold nanoclusters (Au NCs) were obtained by one-pot synthetic method using bovine serum albumin (BSA) and bromelain as templates. As-synthesized fluorescent Au NCs were stable and showed bright red fluorescence under UV lamp at 365 nm. The fluorescent Au NCs exhibit the emission intensity at 648 nm when excited at 498 nm. Various techniques were used such as spectroscopy (UV-visible, fluorescence, and Fourier-transform infrared), high-resolution transmission electron microscopy, and dynamic light scattering for the characterization of fluorescent Au NCs. The values of I 0 /I at 648 nm are proportional to the concentrations of Hg 2+ ion in the range from 0.00075 to 5.0 μM and of lambda-cyhalothrin in the range from 0.01 to 10 μM with detection limits of 0.0003 and 0.0075 μM for Hg 2+ ion and lambda-cyhalothrin, respectively. The practical application of the probe was successfully demonstrated by analyzing Hg 2+ ion and lambda-cyhalothrin in water samples. In addition, Au NCs used as probes for imaging of Simplicillium fungal cells. These results indicated that the as-synthesized Au NCs have proven to be promising fluorescent material for the sensing of Hg 2+ ion and lambda-cyhalothrin in environmental and for imaging of microorganism cells in biomedical applications.

  20. Light transmission and ultraviolet protection of contact lenses under artificial illumination.

    PubMed

    Artigas, José M; Navea, Amparo; García-Domene, M Carmen; Gené, Andrés; Artigas, Cristina

    2016-04-01

    To determine the spectral transmission of contact lenses (CLs), with and without an ultraviolet (UV) filter to evaluate their capacity for protection under UV radiation from artificial illumination (incandescent, fluorescent, xenon (Xe) lamps, or white LEDs (light-emitting diode)). The transmission curves of nine soft CLs were obtained by using a PerkinElmer Lambda 35 UV-vis spectrophotometer. A CIE standard was used for the emission spectra of incandescent and fluorescent lamps, and Xe lamps and white LEDs were measured by using an International Light Technologies ILT-950 spectroradiometer. Five of the nine soft CLs analysed state that they incorporate UV filters, but the other four do not specify anything in this regard. The spectral transmission of all the CLs studied is excellent in the visible region. The CLs with UV filters filter out this radiation more or less effectively. Xe lamps emit a part in the UV region. Incandescent, fluorescent and white LEDs do not emit at all in the UV. Incorporating UV filters is important when the illumination is from a Xe lamp since this light source emits in the UV region. This, however, does not occur with incandescent and fluorescent lamps or white LEDs. The CLs that do incorporate UV filters meet all the standard requirements that the U.S. FDA (Food and Drug Administration) has for UV-blocking CLs Class II (OcularScience, CooperVision and Neolens), and AcuvueMoist and HydronActifresh400 even comply with the stricter Class I. The CLs without UV filters let UVA, UVB and even some UVC through. Copyright © 2015. Published by Elsevier Ltd.

  1. 207-nm UV light - a promising tool for safe low-cost reduction of surgical site infections. I: in vitro studies.

    PubMed

    Buonanno, Manuela; Randers-Pehrson, Gerhard; Bigelow, Alan W; Trivedi, Sheetal; Lowy, Franklin D; Spotnitz, Henry M; Hammer, Scott M; Brenner, David J

    2013-01-01

    0.5% to 10% of clean surgeries result in surgical-site infections, and attempts to reduce this rate have had limited success. Germicidal UV lamps, with a broad wavelength spectrum from 200 to 400 nm are an effective bactericidal option against drug-resistant and drug-sensitive bacteria, but represent a health hazard to patient and staff. By contrast, because of its limited penetration, ~200 nm far-UVC light is predicted to be effective in killing bacteria, but without the human health hazards to skin and eyes associated with conventional germicidal UV exposure. The aim of this work was to test the biophysically-based hypothesis that ~200 nm UV light is significantly cytotoxic to bacteria, but minimally cytotoxic or mutagenic to human cells either isolated or within tissues. A Kr-Br excimer lamp was used, which produces 207-nm UV light, with a filter to remove higher-wavelength components. Comparisons were made with results from a conventional broad spectrum 254-nm UV germicidal lamp. First, cell inactivation vs. UV fluence data were generated for methicillin-resistant S. aureus (MRSA) bacteria and also for normal human fibroblasts. Second, yields of the main UV-associated pre-mutagenic DNA lesions (cyclobutane pyrimidine dimers and 6-4 photoproducts) were measured, for both UV radiations incident on 3-D human skin tissue. We found that 207-nm UV light kills MRSA efficiently but, unlike conventional germicidal UV lamps, produces little cell killing in human cells. In a 3-D human skin model, 207-nm UV light produced almost no pre-mutagenic UV-associated DNA lesions, in contrast to significant yields induced by a conventional germicidal UV lamp. As predicted based on biophysical considerations, 207-nm light kills bacteria efficiently but does not appear to be significantly cytotoxic or mutagenic to human cells. Used appropriately, 207-nm light may have the potential for safely and inexpensively reducing surgical-site infection rates, including those of drug-resistant origin.

  2. Light-scattering measurements of optical thin-film components at 157 and 193 nm

    NASA Astrophysics Data System (ADS)

    Gliech, Stefan; Steinert, Jorg; Duparre, Angela

    2002-06-01

    An instrument for total backscattering and forward-scattering measurements of optical coating components at 157 and 193 nm is described. The system is operated in both vacuum and nitrogen purge gas. An excimer laser as well as a deuterium lamp can be used as a radiation source. Suppression of the background signal level to 1 part in 106 permits measurements even of low-scatter samples such as superpolished substrates and antireflection coatings. Results of investigations of antireflective and highly reflective multilayers and CaF2 substrates reveal scattering from surface and interface roughness as well as from the volume of the substrate material. First steps to extend the instrument for angle-resolved scatter, transmittance, and reflectance measurements are described.

  3. Induction of lambda prophage by 213 nm laser radiation: a quantitative comparison with 193 nm excimer radiation using image analysis.

    PubMed

    Matchette, L S; Grossman, L W; Hahn, D W; Cooney, C

    1996-03-01

    We compared the DNA damage produced by radiation from two UV laser wavelengths, 213 nm and 193 nm, with that produced by noncoherent 254 nm radiation. Following irradiation of Escherichia coli BR339, a bacteriophage lambda lysogen containing the lacZ gene, pro-phage induction was measured by assaying for beta-galactosidase. Because of the limited penetration by UV laser wavelengths an agar overlay of the lysogen was used as the irradiation target. Irradiation of 254 nm was performed in buffer suspension followed by transfer of 5 microL spots onto assay plants. Computer image analysis was used to monitor the rate of product formation, observed as an increase in optical density of the irradiated zones on assay plates. We found that the rate of product formation was a more reproducible unit of comparison than the optical density present at the end of the reaction. Although the rate of product formation was not linearly related to enzyme concentration, the data could be fit to a simple logarithmic function. Using this method, we concluded that the DNA damaging ability of 213 nm radiation was 10 times more efficient than 193 nm radiation and about 100 times less efficient than 254 nm noncoherent radiation.

  4. Impedance matching for repetitive high voltage all-solid-state Marx generator and excimer DBD UV sources

    NASA Astrophysics Data System (ADS)

    Wang, Yonggang; Tong, Liqing; Liu, Kefu

    2017-06-01

    The purpose of impedance matching for a Marx generator and DBD lamp is to limit the output current of the Marx generator, provide a large discharge current at ignition, and obtain fast voltage rising/falling edges and large overshoot. In this paper, different impedance matching circuits (series inductor, parallel capacitor, and series inductor combined with parallel capacitor) are analyzed. It demonstrates that a series inductor could limit the Marx current. However, the discharge current is also limited. A parallel capacitor could provide a large discharge current, but the Marx current is also enlarged. A series inductor combined with a parallel capacitor takes full advantage of the inductor and capacitor, and avoids their shortcomings. Therefore, it is a good solution. Experimental results match the theoretical analysis well and show that both the series inductor and parallel capacitor improve the performance of the system. However, the series inductor combined with the parallel capacitor has the best performance. Compared with driving the DBD lamp with a Marx generator directly, an increase of 97.3% in radiant power and an increase of 59.3% in system efficiency are achieved using this matching circuit.

  5. Comparison of two techniques of marking the horizontal axis during excimer laser keratorefractive surgery for myopic astigmatism.

    PubMed

    Burka, Jenna M; Bower, Kraig S; Cute, David L; Stutzman, Richard D; Subramanian, Prem S; Rabin, Jeff C

    2005-04-01

    To compare two methods of limbal marking used during laser refractive surgery for myopic astigmatism. Retrospective chart review. Forty-two eyes of 42 patients who underwent photorefractive keratectomy (PRK) or laser-assisted in-situ keratomileusis (LASIK) for myopic astigmatism were marked preoperatively to identify the horizontal axis. In 18 eyes, marks were placed at the slit lamp (SL) with the slit beam set at 180 degrees as a reference. In 24 eyes, marks were placed in the laser room (LR) immediately before reclining under the laser. All treatments were performed with the Alcon LADARVision excimer laser system. Vector analysis of postoperative cylinder and reduction in cylinder and uncorrected and best-corrected visual acuity were evaluated for both groups. The mean postoperative magnitude of error was -0.19 +/- 0.44 diopters for the LR group and -0.09 +/- 0.42 diopters for the SL group (P = .439, NS). Both groups had a mean angle of error indicating an overall counterclockwise rotation of axis with an angle of error of 6.3 +/- 8.7 degrees for the LR group and 8.0 +/- 10.2 degrees for the SL group (P = .562, NS). We found no significant difference in outcomes with an overall trend toward undercorrection of cylinder in both groups, leaving room for improvement after refractive surgery for myopic astigmatism.

  6. Photoprotection and photoreception of intraocular lenses under xenon and white LED illumination.

    PubMed

    Artigas, J M; Navea, A; García-Domene, M C; Artigas, C; Lanzagorta, A

    2016-05-01

    To analyze the photoprotection and phototransmission that various intraocular lenses (IOLs) provide under the illumination of a xenon (Xe) lamp and white LEDs (light emitting diode). The spectral transmission curves of six representative IOLs were measured using a Perkin-Elmer Lambda 35 UV/VIS spectrometer. Various filtering simulations were performed using a Xe lamp and white LEDs. The spectral emissions of these lamps were measured with an ILT-950 spectroradiometer. The IOLs analyzed primarily show transmission of nearly 100% in the visible spectrum. In the ultraviolet (UV) region, the filters incorporated in the various IOLs did not filter equally, and some of them let an appreciable amount of UV through. The Xe lamp presented a strong emission of ultraviolet A (UVA), and its emission under 300nm was not negligible. The white LED did not present an appreciable emission under 380nm. The cut-off wavelength of most filters is between 380 and 400nm (Physiol Hydriol60C(®), IOLTECH E4T(®), Alcon SA60AT(®), Alcon IQ SN60WF(®)), so that their UV protection is very effective. Nonetheless, the IOL OPHTEC Oculaid(®) contains a filter that, when a Xe lamp is used, lets through up to 20% for 350nm and up to 15% for 300nm, which at this point is ultraviolet B (UVB). The OPHTEC(®) Artisan IOL has a transmission peak below 300nm, which must be taken into account under Xe illumination. White LEDs do not emit energy below 380nm, so no special protection is required in the UV region. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  7. Fiber optic systems in the UV region

    NASA Astrophysics Data System (ADS)

    Huebner, Michael; Meyer, H.; Klein, Karl-Friedrich; Hillrichs, G.; Ruetting, Martin; Veidemanis, M.; Spangenberg, Bernd; Clarkin, James P.; Nelson, Gary W.

    2000-05-01

    Mainly due to the unexpected progress in manufacturing of solarization-reduced all-silica fibers, new fiber-optic applications in the UV-region are feasible. However, the other components like the UV-sources and the detector- systems have to be improved, too. Especially, the miniaturization is very important fitting to the small-sized fiber-optic assemblies leading to compact and mobile UV- analytical systems. Based on independent improvements in the preform and fiber processing, UV-improved fibers with different properties have been developed. The best UV-fiber for the prosed applications is selectable by its short and long-term spectral behavior, especially in the region from 190 to 350 nm. The spectrum of the UV-source and the power density in the fiber have an influence on the nonlinear transmission and the damaging level; however, hydrogen can reduce the UV-defect concentration. After determining the diffusion processes in the fiber, the UV-lifetime in commercially available all-silica fibers can be predicted. Newest results with light from deuterium-lamps, excimer- lasers and 5th harmonics of Nd:YAG laser will be shown. Many activities are in the field of UV-sources. In addition to new UV-lasers like the Nd:YAG laser at 213 nm, a new low- power deuterium-lamp with smaller dimensions has been introduced last year. Properties of this lamp will be discussed, taking into account some of the application requirements. Finally, some new applications with UV-fiber optics will be shown; especially the TLC-method can be improved significantly, combining a 2-row fiber-array with a diode-array spectrometer optimized for fiber-optics.

  8. Hevin Plays a Pivotal Role in Corneal Wound Healing

    PubMed Central

    Chaurasia, Shyam S.; Perera, Promoda R.; Poh, Rebekah; Lim, Rayne R.; Wong, Tina T.; Mehta, Jodhbir S.

    2013-01-01

    Background Hevin is a matricellular protein involved in tissue repair and remodeling via interaction with the surrounding extracellular matrix (ECM) proteins. In this study, we examined the functional role of hevin using a corneal stromal wound healing model achieved by an excimer laser-induced irregular phototherapeutic keratectomy (IrrPTK) in hevin-null (hevin-/-) mice. We also investigated the effects of exogenous supplementation of recombinant human hevin (rhHevin) to rescue the stromal cellular components damaged by the excimer laser. Methodology/Principal Findings Wild type (WT) and hevin -/- mice were divided into three groups at 4 time points- 1, 2, 3 and 4 weeks. Group I served as naïve without any treatment. Group II received epithelial debridement and underwent IrrPTK using excimer laser. Group III received topical application of rhHevin after IrrPTK surgery for 3 days. Eyes were analyzed for corneal haze and matrix remodeling components using slit lamp biomicroscopy, in vivo confocal microscopy, light microscopy (LM), transmission electron microscopy (TEM), immunohistochemistry (IHC) and western blotting (WB). IHC showed upregulation of hevin in IrrPTK-injured WT mice. Hevin -/- mice developed corneal haze as early as 1-2 weeks post IrrPTK-treatment compared to the WT group, which peaked at 3-4 weeks. They also exhibited accumulation of inflammatory cells, fibrotic components of ECM proteins and vascularized corneas as seen by IHC and WB. LM and TEM showed activated keratocytes (myofibroblasts), inflammatory debris and vascular tissues in the stroma. Exogenous application of rhHevin for 3 days reinstated inflammatory index of the corneal stroma similar to WT mice. Conclusions/Significance Hevin is transiently expressed in the IrrPTK-injured corneas and loss of hevin predisposes them to aberrant wound healing. Hevin -/- mice develop early corneal haze characterized by severe chronic inflammation and stromal fibrosis that can be rescued with exogenous administration of rhHevin. Thus, hevin plays a pivotal role in the corneal wound healing. PMID:24303054

  9. 207-nm UV Light - A Promising Tool for Safe Low-Cost Reduction of Surgical Site Infections. I: In Vitro Studies

    PubMed Central

    Buonanno, Manuela; Randers-Pehrson, Gerhard; Bigelow, Alan W.; Trivedi, Sheetal; Lowy, Franklin D.; Spotnitz, Henry M.; Hammer, Scott M.; Brenner, David J.

    2013-01-01

    Background 0.5% to 10% of clean surgeries result in surgical-site infections, and attempts to reduce this rate have had limited success. Germicidal UV lamps, with a broad wavelength spectrum from 200 to 400 nm are an effective bactericidal option against drug-resistant and drug-sensitive bacteria, but represent a health hazard to patient and staff. By contrast, because of its limited penetration, ∼200 nm far-UVC light is predicted to be effective in killing bacteria, but without the human health hazards to skin and eyes associated with conventional germicidal UV exposure. Aims The aim of this work was to test the biophysically-based hypothesis that ∼200 nm UV light is significantly cytotoxic to bacteria, but minimally cytotoxic or mutagenic to human cells either isolated or within tissues. Methods A Kr-Br excimer lamp was used, which produces 207-nm UV light, with a filter to remove higher-wavelength components. Comparisons were made with results from a conventional broad spectrum 254-nm UV germicidal lamp. First, cell inactivation vs. UV fluence data were generated for methicillin-resistant S. aureus (MRSA) bacteria and also for normal human fibroblasts. Second, yields of the main UV-associated pre-mutagenic DNA lesions (cyclobutane pyrimidine dimers and 6-4 photoproducts) were measured, for both UV radiations incident on 3-D human skin tissue. Results We found that 207-nm UV light kills MRSA efficiently but, unlike conventional germicidal UV lamps, produces little cell killing in human cells. In a 3-D human skin model, 207-nm UV light produced almost no pre-mutagenic UV-associated DNA lesions, in contrast to significant yields induced by a conventional germicidal UV lamp. Conclusions As predicted based on biophysical considerations, 207-nm light kills bacteria efficiently but does not appear to be significantly cytotoxic or mutagenic to human cells. Used appropriately, 207-nm light may have the potential for safely and inexpensively reducing surgical-site infection rates, including those of drug-resistant origin. PMID:24146947

  10. PREFACE: Diagnostics for electrical discharge light sources: pushing the limits Diagnostics for electrical discharge light sources: pushing the limits

    NASA Astrophysics Data System (ADS)

    Zissis, Georges; Haverlag, Marco

    2010-06-01

    Light sources play an indispensable role in the daily life of any human being. Quality of life, health and urban security related to traffic and crime prevention depend on light and on its quality. In fact, every day approximately 30 billion electric light sources operate worldwide. These electric light sources consume almost 19% of worldwide electricity production. Finding new ways to light lamps is a challenge where the stakes are scientific, technological, economic and environmental. The production of more efficient light sources is a sustainable solution for humanity. There are many opportunities for not only enhancing the efficiency and reliability of lighting systems but also for improving the quality of light as seen by the end user. This is possible through intelligent use of new technologies, deep scientific understanding of the operating principles of light sources and knowledge of the varied human requirements for different types of lighting in different settings. A revolution in the domain of light source technology is on the way: high brightness light emitting diodes arriving in the general lighting market, together with organic LEDs (OLEDs), are producing spectacular advances. However, unlike incandescence, electrical discharge lamps are far from disappearing from the market. In addition, new generations of discharge lamps based on molecular radiators are becoming a reality. There are still many scientific and technological challenges to be raised in this direction. Diagnostics are important for understanding the fundamental mechanisms taking place in the discharge plasma. This understanding is an absolute necessity for system optimization leading to more efficient and high quality light sources. The studied medium is rather complex, but new diagnostic techniques coupled to innovative ideas and powerful tools have been developed in recent years. This cluster issue of seven papers illustrates these efforts. The selected papers cover all domains, from high to low pressure and dielectric barrier lamps, from breakdown to acoustic resonance. Especially in the domain of high pressure lamps, J J Curry shows how coherent and incoherent x-ray scattering can be used as an imaging technique adapted to lamps. J Hirsch et al treat the acoustic resonance phenomenon that seriously limits the frequency domain for high pressure lamp operation. M Jinno et al illustrate a method that allows for measuring Xe buffer gas pressure in Hg-free metal halide lamps for automotive applications. In the domain of low pressure lamps, M Gendre et al investigate the breakdown phase by means of optical and electrical diagnostic tools. The similarity rules used a long time ago for simulating plasma behaviour based on invariants are now serving as diagnostic tools, as shown in the paper by D Michael et al. N Dagang et al show how impurities can be detected in Hg-free electrodeless lamps and more particularly in dielectric barrier discharges emitting excimer radiation. The quality of light is illustrated by a final example by R Kozakov et al on how to qualify the light output from the lamp with respect to biological effects on humans.

  11. Silica-Titania Composite (STC)'s Performance in the Photocatalytic Oxidation of Polar VOCs

    NASA Technical Reports Server (NTRS)

    Levine, Lanfang H.; Coutts, Janelle; Richards, Jeffrey; Mazyck, David; Mazyck, David

    2011-01-01

    The objective of this paper is to determine the performance of a Silica-Titania Composite (STC) in the photocatalytic oxidation (PCO) of polar VOCs for potential applications in trace contaminant control within space habitats such as the ISS and CEV Orion. Tests were carried out in a bench scale STC-packed annular reactor under continuous illumination by either a UV-C germicidal lamp(lambda (sub max) = 254 nm) or UV-A fluorescent BLB (lambda(sub max) = 365 nm) for the removal of ethanol (a predominant polar VOC in the ISS cabin). The STC's performance was evaluated in terms of the ethanol mineralization rate, mineralization efficiency, and the extent of its oxidation intermediate (acetaldehyde) formation in response to the type of light source (photon energy and photon flux) and relative humidity (RH) implemented. Results demonstrated that acetaldehyde was the only quantifiable intermediate in the effluent under UV illumination, but was not found in the dark adsorption experiments. The mineralization rate increased with an increase in photon energy (UV-C greater than UV-A), even though both lamps were adjusted to emit the same incident photon flux, and also increased with increasing photon flux. However, photonic efficiency decreased as the photon flux increased. More importantly, a higher photon flux gave rise to a lower effluent acetaldehyde concentration. The effect of RH on PCO was complex and intriguing because it affected both physical adsorption and photocatalytic oxidation. In general, increasing RH caused a decrease in adsorption capacity for ethanol and reduced the mineralization efficiency with a concomitant higher acetaldehyde evolution rate. The effect of RH was less profound than that of photon flux.

  12. The total spectral radiant flux calibration using a spherical spectrometer at National Institute of Metrology China

    NASA Astrophysics Data System (ADS)

    Zhao, Weiqiang; Liu, Hui; Liu, Jian

    2016-11-01

    At present day, in the field of lighting the incandescent lamps are phasing out. The solid state lighting products, i.e. LED, and the related market are developing very fast in China for its promising application, due to the energy-saving and the colorful features. For the quality control and the commercial trade purpose, it is highly necessary to measure the optical parameters of LED light sources with a fast, easy and affordable facility. Therefore, more test labs use the spherical spectrometer to measure LED. The quasi- monochrome of LED and the V(lambda) of silicon photodetector mismatch problem is reduced or avoided, because the total spectral radiant flux (TSRF) is measured, and all the optical parameters are calculate from the TSRF. In such a way, the spherical spectrometer calibration requires TSRF standard lamps instead of the traditional total flux standard lamps. National Institute of Metrology China (NIM) has studied and developed the facilities for TSRF measurement and provides related calibration services. This paper shows the TSRF standard lamp calibration procedure using a spherical spectrometer in every-day calibration and its traceable link to the primary SI unit at NIM. The sphere is of 1.5 m diameter, and installed with a spectrometer and a silicon photodetector. It also shows the detail of data process, such as the spectral absorption correction method and the calculation of the result derived from the spectral readings. The TSRF calibration covers the spectra range of 350 nm to 1050 nm, with a measurement uncertainty of 3.6% 1.8% (k=2).

  13. Surface Chemical Conversion of Organosilane Self-Assembled Monolayers with Active Oxygen Species Generated by Vacuum Ultraviolet Irradiation of Atmospheric Oxygen Molecules

    NASA Astrophysics Data System (ADS)

    Kim, Young-Jong; Lee, Kyung-Hwang; Sano, Hikaru; Han, Jiwon; Ichii, Takashi; Murase, Kuniaki; Sugimura, Hiroyuki

    2008-01-01

    The chemical conversion of the top surface of n-octadecyltrimethoxy silane self-assembled monolayers (ODS-SAMs) on oxide-covered Si substrates using active oxygen species generated from atmospheric oxygen molecules irradiated with vacuum ultraviolet (VUV) light at 172 nm in wavelength has been studied on the basis of water contact angle measurements, ellipsometry, X-ray photoelectron spectroscopy, and atomic force microscopy. An ODS-SAM whose water contact angle was 104° on average was prepared using chemical vapor deposition with substrate and vapor temperatures of 150 °C. The VUV treatment of an ODS-SAM sample was carried out by placing the sample in air and then irradiating the sample surface with a Xe-excimer lamp. The distance between the lamp and the sample was regulated so that the VUV light emitted from the lamp was almost entirely absorbed by atmospheric oxygen molecules to generate active oxygen species, such as ozone and atomic oxygen before reaching the sample surface. Hence, the surface chemical conversion of the ODS-SAM was primarily promoted through chemical reactions with the active oxygen species. Photochemical changes in the ODS-SAM were found to be the generation of polar functional groups, such as -COOH, -CHO, and -OH, on the surface and the subsequent etching of the monolayer. Irradiation parameters, such as irradiation time, were optimized to achieve a better functionalization of the SAM top surface while minimizing the etching depth of the ODS-SAM. The ability to graft another SAM onto the modified ODS-SAM bearing polar functional groups was demonstrated by the formation of alkylsilane bilayers.

  14. Germicidal Efficacy and Mammalian Skin Safety of 222-nm UV Light

    PubMed Central

    Buonanno, Manuela; Ponnaiya, Brian; Welch, David; Stanislauskas, Milda; Randers-Pehrson, Gerhard; Smilenov, Lubomir; Lowy, Franklin D.; Owens, David M.; Brenner, David J.

    2017-01-01

    We have previously shown that 207-nm ultraviolet (UV) light has similar antimicrobial properties as typical germicidal UV light (254 nm), but without inducing mammalian skin damage. The biophysical rationale is based on the limited penetration distance of 207-nm light in biological samples (e.g. stratum corneum) compared with that of 254-nm light. Here we extended our previous studies to 222-nm light and tested the hypothesis that there exists a narrow wavelength window in the far-UVC region, from around 200–222 nm, which is significantly harmful to bacteria, but without damaging cells in tissues. We used a krypton-chlorine (Kr-Cl) excimer lamp that produces 222-nm UV light with a bandpass filter to remove the lower- and higher-wavelength components. Relative to respective controls, we measured: 1. in vitro killing of methicillin-resistant Staphylococcus aureus (MRSA) as a function of UV fluence; 2. yields of the main UV-associated premutagenic DNA lesions (cyclobutane pyrimidine dimers and 6-4 photoproducts) in a 3D human skin tissue model in vitro; 3. eight cellular and molecular skin damage endpoints in exposed hairless mice in vivo. Comparisons were made with results from a conventional 254-nm UV germicidal lamp used as positive control. We found that 222-nm light kills MRSA efficiently but, unlike conventional germicidal UV lamps (254 nm), it produces almost no premutagenic UV-associated DNA lesions in a 3D human skin model and it is not cytotoxic to exposed mammalian skin. As predicted by biophysical considerations and in agreement with our previous findings, far-UVC light in the range of 200–222 nm kills bacteria efficiently regardless of their drug-resistant proficiency, but without the skin damaging effects associated with conventional germicidal UV exposure. PMID:28225654

  15. Germicidal Efficacy and Mammalian Skin Safety of 222-nm UV Light.

    PubMed

    Buonanno, Manuela; Ponnaiya, Brian; Welch, David; Stanislauskas, Milda; Randers-Pehrson, Gerhard; Smilenov, Lubomir; Lowy, Franklin D; Owens, David M; Brenner, David J

    2017-04-01

    We have previously shown that 207-nm ultraviolet (UV) light has similar antimicrobial properties as typical germicidal UV light (254 nm), but without inducing mammalian skin damage. The biophysical rationale is based on the limited penetration distance of 207-nm light in biological samples (e.g. stratum corneum) compared with that of 254-nm light. Here we extended our previous studies to 222-nm light and tested the hypothesis that there exists a narrow wavelength window in the far-UVC region, from around 200-222 nm, which is significantly harmful to bacteria, but without damaging cells in tissues. We used a krypton-chlorine (Kr-Cl) excimer lamp that produces 222-nm UV light with a bandpass filter to remove the lower- and higher-wavelength components. Relative to respective controls, we measured: 1. in vitro killing of methicillin-resistant Staphylococcus aureus (MRSA) as a function of UV fluence; 2. yields of the main UV-associated premutagenic DNA lesions (cyclobutane pyrimidine dimers and 6-4 photoproducts) in a 3D human skin tissue model in vitro; 3. eight cellular and molecular skin damage endpoints in exposed hairless mice in vivo. Comparisons were made with results from a conventional 254-nm UV germicidal lamp used as positive control. We found that 222-nm light kills MRSA efficiently but, unlike conventional germicidal UV lamps (254 nm), it produces almost no premutagenic UV-associated DNA lesions in a 3D human skin model and it is not cytotoxic to exposed mammalian skin. As predicted by biophysical considerations and in agreement with our previous findings, far-UVC light in the range of 200-222 nm kills bacteria efficiently regardless of their drug-resistant proficiency, but without the skin damaging effects associated with conventional germicidal UV exposure.

  16. Applications of the Excimer Laser: A Review.

    PubMed

    Beggs, Sarah; Short, Jack; Rengifo-Pardo, Monica; Ehrlich, Alison

    2015-11-01

    The 308-nm excimer laser has been approved by the Food and Drug Administration for the treatment of psoriasis and vitiligo. Its ability to treat localized areas has led to many studies determining its potential in the treatment of focal diseases with inflammation or hypopigmentation. To review the different applications of the 308-nm excimer laser for treating dermatologic conditions. An extensive literature review was conducted by searching PubMed, MEDLINE, and ClinicalKey to find articles pertaining to dermatologic conditions treated with the 308-nm excimer laser. Articles published that contributed to new applications of the excimer laser were included, as well as initial studies utilizing the excimer laser. The outcomes and results were compiled for different dermatologic conditions treated with the excimer laser. The 308-nm excimer laser has a wide range of uses for focal inflammatory and hypopigmented conditions. Treatment is generally well tolerated, with few adverse reactions. Larger studies and studies evaluating the long-term effects of the 308-nm excimer laser are needed.

  17. Rapid comprehensive characterization of crude oils by thermogravimetry coupled to fast modulated gas chromatography-single photon ionization time-of-flight mass spectrometry.

    PubMed

    Wohlfahrt, S; Fischer, M; Saraji-Bozorgzad, M; Matuschek, G; Streibel, T; Post, E; Denner, T; Zimmermann, R

    2013-09-01

    Comprehensive multi-dimensional hyphenation of a thermogravimetry device (i.e. a thermobalance) to gas chromatography and single photon ionization-time-of-flight mass spectrometry (TG-GC×SPI-MS) has been used to investigate two crude oil samples of different geographical origin. The source of the applied vacuum ultraviolet radiation is an electron beam pumped rare gas excimer lamp (EBEL). The soft photoionization favors the formation of molecular ions. Introduction of a fast, rapidly modulated gas chromatographic separation step in comparison with solely TG-SPI-MS enables strongly enhanced detection especially with such highly complex organic matrices as crude oil. In contrast with former TG-SPI-MS measurements, separation and identification of overlying substances is possible because of different GC retention times. The specific contribution of isobaric compounds to one mass signal is determined for alkanes, naphthalenes, alkylated benzenes, and other compounds.

  18. Foundations of atmospheric pressure non-equilibrium plasmas

    NASA Astrophysics Data System (ADS)

    Bruggeman, Peter J.; Iza, Felipe; Brandenburg, Ronny

    2017-12-01

    Non-equilibrium plasmas have been intensively studied over the past century in the context of material processing, environmental remediation, ozone generation, excimer lamps and plasma display panels. Research on atmospheric pressure non-equilibrium plasmas intensified over the last two decades leading to a large variety of plasma sources that have been developed for an extended application range including chemical conversion, medicine, chemical analysis and disinfection. The fundamental understanding of these discharges is emerging but there remain a lot of unexplained phenomena in these intrinsically complex plasmas. The properties of non-equilibrium plasmas at atmospheric pressure span over a huge range of electron densities as well as heavy particle and electron temperatures. This paper provides an overview of the key underlying processes that are important for the generation and stabilization of atmospheric pressure non-equilibrium plasmas. The unique physical and chemical properties of theses discharges are also summarized.

  19. Laser induced OMCVD growth of AlGaAs on GaAs

    NASA Technical Reports Server (NTRS)

    Wilt, David M.; Warner, Joseph D.; Aron, Paul R.; Pouch, John J.; Hoffman, Richard W., Jr.

    1987-01-01

    A major factor limiting the efficiency of the GaAs-GaAlAs solar cell is the rate of recombination at the GaAs-AlGaAs interface. Evidence has been previously reported which indicates that recombination at this interface can be greatly reduced if the AlGaAs layer is grown at lower than normal temperatures. The authors examine the epitaxial growth of AlGaAs on GaAs using a horizontal OMCVD reactor and an excimer laser operating in the UV (lambda = 193 nm) region. The growth temperatures were 450 and 500 C. The laser beam was utilized in two orientations: 75 deg angle of incidence and parallel to the substrate. Film composition and structure were determined by Auger electron spectroscopy (AES) and transmission electron microscopy (TEM). Auger analysis of epilayers grown at 500 C with the laser impinging show no carbon or oxygen contamination of the epitaxial layers or interfaces. TEM diffraction patterns of these same epilayers exhibit single crystal (100) zone axis patterns.

  20. Influence of a TiN interlayer on the microstructure and mechanical properties of hydroxyapatite films grown by pulsed laser deposition

    NASA Astrophysics Data System (ADS)

    Nelea, Valentin D.; Ristoscu, Carmen; Colis, Silviu; Arens, Simona; Pelletier, Herve; Mihailescu, Ion N.; Mille, Pierre

    2001-04-01

    Crystalline hydroxyapatite (HA) thin films grown on metallic substrates is the best choice for bone restoration. This is due to the good biological compatibility of the hydroxyapatite material combined with the good mechanical characteristics of the substrates. We deposit HA thin films by Pulsed Laser Deposition (PLD) in vacuum at room temperature using a KrF* excimer laser ((lambda) equals 248 nm, (tau) FWHM >= 20 ns). The depositions were performed directly on Ti-5Al-2.5Fe or on substrates previously coated with a TiN buffer layer. The HA deposited structures were characterized by complementary techniques: GIXRD, SEM, TEM, SAED, EDS and nanoindentation. Properties of the HA films grown with and without the TiN buffer were discussed in term of microstructure and mechanical behavior. The films with interlayer preserve the stoichiometry, are completely recrystallized and present better mechanical characteristics as compared with those without buffer.

  1. Excimer laser system Profile-500

    NASA Astrophysics Data System (ADS)

    Atejev, V. V.; Bukreyev, V. S.; Vartapetov, Serge K.; Semenov, A. D.; Sugrobov, V. A.; Turin, V. S.; Fedorov, Sergei N.

    1999-07-01

    The description of ophthalmological excimer laser system 'PROFILE-500' for photorefractive and physiotherapeutic keratectomy is presented. Excimer Laser Systems 'PROFILE- 500' are optical system that use ArF excimer lasers to perform photorefractive keratectomy or LASIK; surgical procedures used to correct myopia, hyperopia and astigmatism.

  2. Excimer laser calibration system.

    PubMed

    Gottsch, J D; Rencs, E V; Cambier, J L; Hall, D; Azar, D T; Stark, W J

    1996-01-01

    Excimer laser photoablation for refractive and therapeutic keratectomies has been demonstrated to be feasible and practicable. However, corneal laser ablations are not without problems, including the delivery and maintenance of a homogeneous beam. We have developed an excimer laser calibration system capable of characterizing a laser ablation profile. Beam homogeneity is determined by the analysis of a polymethylmethacrylate (PMMA)-based thin-film using video capture and image processing. The ablation profile is presented as a color-coded map. Interpolation of excimer calibration system analysis provides a three-dimensional representation of elevation profiles that correlates with two-dimensional scanning profilometry. Excimer calibration analysis was performed before treating a monkey undergoing phototherapeutic keratectomy and two human subjects undergoing myopic spherocylindrical photorefractive keratectomy. Excimer calibration analysis was performed before and after laser refurbishing. Laser ablation profiles in PMMA are resolved by the excimer calibration system to .006 microns/pulse. Correlations with ablative patterns in a monkey cornea were demonstrated with preoperative and postoperative keratometry using corneal topography, and two human subjects using video-keratography. Excimer calibration analysis predicted a central-steep-island ablative pattern with the VISX Twenty/Twenty laser, which was confirmed by corneal topography immediately postoperatively and at 1 week after reepithelialization in the monkey. Predicted central steep islands in the two human subjects were confirmed by video-keratography at 1 week and at 1 month. Subsequent technical refurbishing of the laser resulted in a beam with an overall increased ablation rate measured as microns/pulse with a donut ablation profile. A patient treated after repair of the laser electrodes demonstrated no central island. This excimer laser calibration system can precisely detect laser-beam ablation profiles. The calibration system correctly predicted central islands after excimer photoablation in a treated monkey cornea and in two treated human subjects. Detection of excimer-laser-beam ablation profiles may be useful for precise calibration of excimer lasers before human photorefractive and therapeutic surgery.

  3. Excimer lasers

    NASA Technical Reports Server (NTRS)

    Palmer, A. J.; Hess, L. D.; Stephens, R. R.

    1976-01-01

    A theoretical and experimental investigation into the possibility of achieving CW discharge pumped excimer laser oscillation is reported. Detailed theoretical modeling of capillary discharge pumping of the XeF and KXe and K2 excimer systems was carried out which predicted the required discharge parameters for reaching laser threshold on these systems. Capillary discharge pumping of the XeF excimer system was investigated experimentally. The experiments revealed a lower excimer level population density than predicted theoretically by about an order of magnitude. The experiments also revealed a fluorine consumption problem in the discharge in agreement with theory.

  4. Development of nanostructured EuAl2O4 phosphors with strong long-UV excitation.

    PubMed

    Hirata, Gustavo A; Bosze, Eric J; McKittrick, Joanna

    2008-12-01

    Fueled by the need to develop novel materials for applications in solid state white-emitting lamps we have improved a new low-cost, clean and efficient technique to produce high luminescence phosphors with strong excitation in the long-UV range (350-400 nm) which makes them useful for applications in GaN-based solid state lamps. In this work, pressurized combustion synthesis has been successfully used to develop EuAl2O4 (europium aluminate), a new green photoluminescent material with monoclinic structure. The combustion synthesis reaction conditions can be adjusted to produce either the AlEuO3 orthorhombic phase at low pressures (0.1 MPa), or the new monoclinic EuAl2O4 phase, which is apparently more thermodynamically favorable at higher combustion reaction pressures (1.4 MPa). The luminescent material is a high surface area powder (approximately 50 m2/g) composed mainly of nanostructured needles and plates with 5-10 nm in diameter and 100-150 nm in length. A broad emission peak centered at 530 nm with a decay time of 1.5 approximately 2 ms is obtained at the maximum excitation wavelength lambda(exc) = 370 nm.

  5. The Progression of Haze Formation in Rabbit Corneas Following Phototherapeutic Keratectomy

    PubMed Central

    Gibson, Daniel J.; Tuli, Sonal S.; Schultz, Gregory S.

    2013-01-01

    Purpose. To determine the topographical location and time course of development of corneal haze in a phototherapeutic keratectomy model using slit lamp examination, macrophotography, quantitative image analysis, and immunofluorescence staining of corneal sections. Methods. Rabbit corneas were ablated with an excimer laser and were observed and graded for haze via slit lamp, imaged, and graded by macrophotography. Corneal sections were stained for α-smooth muscle actin (α-SMA) and tenascin-C (TNC). The distribution of haze imaged in the macrophotographs and density of α-SMA and TNC staining were compared. A daily image time course of haze formation was generated using macrophotography. Results. The first signs of corneal haze were apparent shortly after reepithelialization. The haze was distributed as a ring at the wound margin in all cases, while nearly all corneas also had some central islands of haze initiation. With time, the haze spread within the ablated zone and intensified. The pattern of immunofluorescent staining for α-SMA and TNC at the wound margin mirrored the haze distribution, spread, and intensification with time. Conclusions. The initiation and spread of subepithelial haze begins shortly after reepithelialization. The haze then spreads from the loci of initiation and becomes more dense with time, maturing as early as 14 days after wounding. The improved temporal and spatial resolution provided by these data improve the current model of light-scattering haze formation in wounded corneas, which will improve the design of studies aimed at maintaining corneal clarity following acute injury or surgery. PMID:23800768

  6. Combination treatment with excimer laser and narrowband UVB light in vitiligo patients.

    PubMed

    Shin, Sungsik; Hann, Seung-Kyung; Oh, Sang Ho

    2016-01-01

    For the treatment of vitiligo, narrowband UVB (NBUVB) light is considered the most effective for nonsegmental vitiligo, while excimer laser treatment is commonly used for localized vitiligo. However, treatment areas may potentially be missed with excimer laser treatment. We aimed to evaluate the effect of combinational treatment with NBUVB light and excimer laser on vitiligo. All patients were first treated with NBUVB; excimer laser was then applied in conjunction with NBUVB phototherapy due to a slow response or no further improvement with continuous NBUVB treatment alone. To minimize adverse effects, a fixed dose of NBUVB was administered, and the dose of excimer laser was increased based on patient response. Among 80 patients, 54 patients showed responses after combination with excimer laser; however, 26 patients (32.5%) showed no remarkable change after combination therapy. Of the 26 patients who showed no further response, 12 patients (46.1%) presented with vitiligo on the acral areas, which are known to the least responsive sites. Our study suggests that combined treatment of NBUVB and excimer laser in vitiligo may enhance the treatment response without remarkable side effects, therefore might also increase the compliance of the patients to the treatment. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Direct Observation of Excimer-Mediated Intramolecular Electron Transfer in a Cofacially-Stacked Perylene Bisimide Pair.

    PubMed

    Sung, Jooyoung; Nowak-Król, Agnieszka; Schlosser, Felix; Fimmel, Benjamin; Kim, Woojae; Kim, Dongho; Würthner, Frank

    2016-07-27

    We have elucidated excimer-mediated intramolecular electron transfer in cofacially stacked PBIs tethered by two phenylene-butadiynylene loops. The electron transfer between energetically equivalent PBIs is revealed by the simultaneous observation of the PBI radical anion and cation bands in the transient absorption spectra. The fluorescence decay time of the excimer states is in good agreement with the rise time of PBI radical bands in transient absorption spectra suggesting that the electron transfer dynamics proceed via the excimer state. We can conclude that the excimer state effectuates the efficient charge transfer in the cofacially stacked PBI dimer.

  8. Design and performance of a production-worthy excimer-laser-based stepper

    NASA Astrophysics Data System (ADS)

    Unger, Robert; Sparkes, Christopher; Disessa, Peter A.; Elliott, David J.

    1992-06-01

    Excimer-laser-based steppers have matured to a production-worthy state. Widefield high-NA lenses have been developed and characterized for imaging down to 0.35 micron and below. Excimer lasers have attained practical levels of performance capability and stability, reliability, safety, and operating cost. Excimer stepper system integration and control issues such as focus, exposure, and overlay stability have been addressed. Enabling support technologies -- resist systems, resist processing, metrology and conventional mask making -- continue to progress and are becoming available. This paper discusses specific excimer stepper design challenges, and presents characterization data from several field installations of XLSTM deep-UV steppers configured with an advanced lens design.

  9. Inactivation of Bacillus atrophaeus by OH radicals

    NASA Astrophysics Data System (ADS)

    Ono, Ryo; Yonetamari, Kenta; Tokumitsu, Yusuke; Yonemori, Seiya; Yasuda, Hachiro; Mizuno, Akira

    2016-08-01

    The inactivation of Bacillus atrophaeus by OH radicals is measured. This study aims to evaluate the bactericidal effects of OH radicals produced by atmospheric-pressure nonthermal plasma widely used for plasma medicine; however, in this study, OH radicals are produced by vacuum ultraviolet (VUV) photolysis of water vapor instead of plasma to allow the production of OH radicals with almost no other reactive species. A 172 nm VUV light from a Xe2 excimer lamp irradiates a He-H2O mixture flowing in a quartz tube to photodissociate H2O to produce OH, H, O, HO2, H2O2, and O3. The produced reactive oxygen species (ROS) flow out of the quartz tube nozzle to the bacteria on an agar plate and cause inactivation. The inactivation by OH radicals among the six ROS is observed by properly setting the experimental conditions with the help of simulations calculating the ROS densities. A 30 s treatment with approximately 0.1 ppm OH radicals causes visible inactivation.

  10. Collective phenomena in volume and surface barrier discharges

    NASA Astrophysics Data System (ADS)

    Kogelschatz, U.

    2010-11-01

    Barrier discharges are increasingly used as a cost-effective configuration to produce non-equilibrium plasmas at atmospheric pressure. This way, copious amounts of electrons, ions, free radicals and excited species can be generated without significant heating of the background gas. In most applications the barrier is made of dielectric material. Major applications utilizing mainly dielectric barriers include ozone generation, surface cleaning and modification, polymer and textile treatment, sterilization, pollution control, CO2 lasers, excimer lamps, plasma display panels (flat TV screens). More recent research efforts are devoted to biomedical applications and to plasma actuators for flow control. Sinusoidal feeding voltages at various frequencies as well as pulsed excitation schemes are used. Volume as well as surface barrier discharges can exist in the form of filamentary, regularly patterned or diffuse, laterally homogeneous discharges. The physical effects leading to collective phenomena in volume and surface barrier discharges are discussed in detail. Special attention is paid to self-organization of current filaments and pattern formation. Major similarities of the two types of barrier discharges are elaborated.

  11. Excimer laser: a module of the alopecia areata common protocol.

    PubMed

    McMichael, Amy J

    2013-12-01

    Alopecia areata (AA) is an autoimmune condition characterized by T cell-mediated attack of the hair follicle. The inciting antigenic stimulus is unknown. A dense perbulbar lymphocytic infiltrate and reproducible immunologic abnormalities are hallmark features of the condition. The cellular infiltrate primarily consists of activated T lymphocytes and antigen-presenting Langerhans cells. The xenon chloride excimer laser emits its total energy at the wavelength of 308 nm and therefore is regarded as a "super-narrowband" UVB light source. Excimer laser treatment is highly effective in psoriasis, another T cell-mediated disorder that shares many immunologic features with AA. The excimer laser is superior in inducing T cell apoptosis in vitro compared with narrowband UVB, with paralleled improved clinical efficacy. The excimer laser has been used successfully in patients with AA. In this context, evaluation of the potential benefit of 308-nm excimer laser therapy in the treatment of AA is clinically warranted. Herein, the use of a common treatment protocol with a specifically designed module to study the outcome of excimer laser treatment on moderate-to-severe scalp AA in adults is described.

  12. Studies in fiber guided excimer laser surgery for cutting and drilling bone and meniscus.

    PubMed

    Dressel, M; Jahn, R; Neu, W; Jungbluth, K H

    1991-01-01

    Our experiments on transmitting high-power excimer laser pulses through optical fibers and our investigations on excimer laser ablation of hard tissue show the feasibility of using the excimer laser as an additional instrument in general and accident surgery involving minimal invasive surgery. By combining XeCl-excimer lasers and tapered fused silica fibers we obtained output fluences up to 32 J/cm2 and ablation rates of 3 microns/pulse of hard tissue. This enables us to cut bone and cartilage in a period of time which is suitable for clinical operations. Various experiments were carried out on cadavers in order to optimize the parameters of the excimer laser and fibers: e.g., wavelength, pulse duration, energy, repetition rate, fiber core diameter. The surfaces of the cut tissue are comparable to cuts with conventional instruments. No carbonisation was observed. The temperature increase is below 40 degrees C in the tissue surrounding the laser spot. The healing rate of an excimer laser cut is not slower than mechanical treatments; the quality is comparable.

  13. Mini-excimer laser corneal reshaping using a scanning device

    NASA Astrophysics Data System (ADS)

    Lin, Jui T.

    1994-07-01

    In this paper we present an update on the Mini-Excimer photorefractive keratectomy (PRK) laser system with an emphasis on the scanning device. We also compare the systems of various manufacturers. This paper also presents PMMA ablation profiles and clinical results from China with over 100 cases of myopic corrections ranging from -2.5 D to -12 D. In contrast to the old technology which uses industrial-type high-power excimer lasers, the advanced Mini-Excimer system uses the most recent technology involving a compact, high repetition-rate excimer laser operated at a much smaller beam spot size of (0.8 - 1.2) mm in a scanning mode which requires a beam energy per pulse of only (0.9 - 1.2) mJ on the corneal surface to achieve the same range of fluence (or energy density) (160 - 200) mJ/cm2 as that of the high-power excimer lasers.

  14. Excimer laser for the treatment of psoriasis: safety, efficacy, and patient acceptability

    PubMed Central

    Abrouk, Michael; Levin, Ethan; Brodsky, Merrick; Gandy, Jessica R; Nakamura, Mio; Zhu, Tian Hao; Farahnik, Benjamin; Koo, John; Bhutani, Tina

    2016-01-01

    Introduction The 308 nm excimer laser is a widely used device throughout the field of dermatology for many diseases including psoriasis. Although the laser has demonstrated clinical efficacy, there is a lack of literature outlining the safety, efficacy, and patient acceptability of the excimer laser. Methods A literature search on PubMed was used with combinations of the terms “excimer”, “excimer laser”, “308 nm”, “psoriasis”, “protocol”, “safety”, “efficacy”, acceptability”, “side effects”, and “dose”. The search results were included if they contained information pertaining to excimer laser and psoriasis treatment and description of the safety, efficacy, and patient acceptability of the treatment. Results The 308 nm excimer laser is generally safe and well tolerated with minimal side effects including erythema, blistering, and pigmentary changes. It has a range of efficacies depending on the protocol used with several different treatment protocols, including the induration protocol, the minimal erythema dose protocol, and the newer minimal blistering dose protocol. Conclusion Although the excimer laser is not a first-line treatment, it remains an excellent treatment option for psoriasis patients and has been demonstrated to be an effective treatment with little to no side effects. PMID:29387603

  15. Ultrafast photo-initiated molecular quantum dynamics in the DNA dinucleotide d(ApG) revealed by broadband transient absorption spectroscopy.

    PubMed

    Stuhldreier, Mayra C; Temps, Friedrich

    2013-01-01

    The ultrafast photo-initiated quantum dynamics of the adenine-guanine dinucleotide d(ApG) in aqueous solution (pH 7) has been studied by femtosecond time-resolved spectroscopy after excitation at lambda = 260 nm. The results reveal a hierarchy of processes on time scales from tau < 100 fs to tau > 100 ps. Characteristic spectro-temporal signatures are observed indicating the transformation of the molecules in the electronic relaxation from the photo-excited state to a long-lived exciplex. In particular, broadband UV/VIS excited-state absorption (ESA) measurements detected a distinctive absorption by the excited dinucleotide around lambda = 335 nm, approximately 0.5 eV to the blue compared to the maximum of the broad and unstructured ESA spectrum after excitation of an equimolar mixture of the mononucleotides dAMP and dGMP. A similar feature has been identified as signature of the excimer in the dynamics of the adenine dinucleotide d(ApA). The lifetime of the d(ApG) exciplex was found to be tau = 124 +/- 4 ps both from the ESA decay time and from the ground-state recovery time, far longer than the sub-picosecond lifetimes of excited dAMP or dGMP. Fluorescence-time profiles measured by the up-conversion technique indicate that the exciplex state is reached around approximately 6 ps after excitation. Very weak residual fluorescence at longer times red-shifted to the emission from the photo-excited state shows that the exciplex is almost optically dark, but still has enough oscillator strength to give rise to the dual fluorescence of the dinucleotide in the static fluorescence spectrum.

  16. Excimer lasers

    NASA Technical Reports Server (NTRS)

    Palmer, A. J.; Hess, L. D.; Stephens, R. R.; Pepper, D. M.

    1977-01-01

    The results of a two-year investigation into the possibility of developing continuous wave excimer lasers are reported. The program included the evaluation and selection of candidate molecular systems and discharge pumping techniques. The K Ar/K2 excimer dimer molecules and the xenon fluoride excimer molecule were selected for study; each used a transverse and capillary discharges pumping technique. Experimental and theoretical studies of each of the two discharge techniques applied to each of the two molecular systems are reported. Discharge stability and fluorine consumption were found to be the principle impediments to extending the XeF excimer laser into the continuous wave regime. Potassium vapor handling problems were the principal difficulty in achieving laser action on the K Ar/K2 system. Of the four molecular systems and pumping techniques explored, the capillary discharge pumped K Ar/K2 system appears to be the most likely candidate for demonstrating continuous wave excimer laser action primarily because of its predicted lower pumping threshold and a demonstrated discharge stability advantage.

  17. Endothermic singlet fission is hindered by excimer formation

    NASA Astrophysics Data System (ADS)

    Dover, Cameron B.; Gallaher, Joseph K.; Frazer, Laszlo; Tapping, Patrick C.; Petty, Anthony J.; Crossley, Maxwell J.; Anthony, John E.; Kee, Tak W.; Schmidt, Timothy W.

    2018-03-01

    Singlet fission is a process whereby two triplet excitons can be produced from one photon, potentially increasing the efficiency of photovoltaic devices. Endothermic singlet fission is desired for a maximum energy-conversion efficiency, and such systems have been considered to form an excimer-like state with multiexcitonic character prior to the appearance of triplets. However, the role of the excimer as an intermediate has, until now, been unclear. Here we show, using 5,12-bis((triisopropylsilyl)ethynyl)tetracene in solution as a prototypical example, that, rather than acting as an intermediate, the excimer serves to trap excited states to the detriment of singlet-fission yield. We clearly demonstrate that singlet fission and its conjugate process, triplet-triplet annihilation, occur at a longer intermolecular distance than an excimer intermediate would impute. These results establish that an endothermic singlet-fission material must be designed to avoid excimer formation, thus allowing singlet fission to reach its full potential in enhancing photovoltaic energy conversion.

  18. Endothermic singlet fission is hindered by excimer formation.

    PubMed

    Dover, Cameron B; Gallaher, Joseph K; Frazer, Laszlo; Tapping, Patrick C; Petty, Anthony J; Crossley, Maxwell J; Anthony, John E; Kee, Tak W; Schmidt, Timothy W

    2018-03-01

    Singlet fission is a process whereby two triplet excitons can be produced from one photon, potentially increasing the efficiency of photovoltaic devices. Endothermic singlet fission is desired for a maximum energy-conversion efficiency, and such systems have been considered to form an excimer-like state with multiexcitonic character prior to the appearance of triplets. However, the role of the excimer as an intermediate has, until now, been unclear. Here we show, using 5,12-bis((triisopropylsilyl)ethynyl)tetracene in solution as a prototypical example, that, rather than acting as an intermediate, the excimer serves to trap excited states to the detriment of singlet-fission yield. We clearly demonstrate that singlet fission and its conjugate process, triplet-triplet annihilation, occur at a longer intermolecular distance than an excimer intermediate would impute. These results establish that an endothermic singlet-fission material must be designed to avoid excimer formation, thus allowing singlet fission to reach its full potential in enhancing photovoltaic energy conversion.

  19. Effect of a 308-nm excimer laser on atopic dermatitis-like skin lesions in NC/Nga mice.

    PubMed

    Oh, Chang Taek; Kwon, Tae-Rin; Seok, Joon; Choi, Eun Ja; Kim, Soon Re; Jang, Yu-Jin; Mun, Seog Kyun; Kim, Chan Woong; Lee, Sungeun; Lee, Jongmin; Kim, Myeung Nam; Choi, Sun Young; Kim, Beom Joon

    2016-08-01

    Atopic dermatitis (AD) is a common inflammatory skin disease that can affect all age groups. It has a relapsing course, which dramatically affects the quality of life of patients. A 308-nm excimer laser has been reported to be a safe and effective treatment for inflammatory skin diseases, although the range of potential application has not been fully explored. The purpose of this study was to evaluate the therapeutic effects of a 308-nm laser on AD-like skin lesions in NC/Nga mice. Dermatophagoides farinae-exposed NC/Nga mice with a clinical score of 12 were treated with either a 308-nm excimer laser or narrowband-UVB (NB-UVB). The effects of the 308-nm excimer laser were evaluated by dermatitis scores, skin histology, skin barrier function, and immunological parameters, including IgE and Th2-mediated cytokines. The 308-nm excimer laser significantly reduced the severity of skin lesions and decreased the total serum levels of IgE and Th2-mediated cytokines. The excimer laser also significantly reduced the inflammatory cellular infiltrate into AD-induced skin lesions. Moreover, treatment with the 308-nm excimer laser led to recovery of skin barrier function in AD-induced skin lesions. The 308-nm excimer laser can be considered a valid and safe therapeutic option for the treatment of localized AD. Lasers Surg. Med. 48:629-637, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  20. Application of LIF technique for the space- and time-resolved monitoring of pollutant gas decomposition in nonthermal plasma reactors

    NASA Astrophysics Data System (ADS)

    Mizeraczyk, Jerzy; Ohkubo, Toshikazu; Kanazawa, Seiji; Kocik, Marek

    2003-10-01

    Laser-induced fluorescence (LIF) technique aided by intensified CCD light signal detection and fast digital image processing is demonstrated to be a useful diagnostic method for in-situ observation of the discharge-induced plasma-chemistry processes responsible for NOx(NO + NO2) decomposition occurring in non-thermal plasma reactors. In this paper a method and results of the LIF measurement of two-dimensional distribution of the ground-state NO molecule density inside a DC positive streamer corona reactor during NO removal from a flue gas simulator [air/NO(up to 300 ppm)] are presented. Either a needle-to-plate or nozzle-to-plate electrode system, having an electrode gap of 30-50 mm was used for generating the corona discharge in the reactor. The LIF monitoring of NO molecules was carried out under the steady-state DC corona discharge condition. The laser-induced fluorescence on the transition NO X2Π(v"=0)<--A2Σ+(v'=0) at λ=226nm was chosen for monitoring ground-state NO molecules in the reactor. This transition was induced by irradiation of the NO molecules with UV laser pulses generated by a laser system consisted of a XeF excimer laser, dye laser and BBO crystal. The laser pulses from the XeF excimer laser (Lambda Physik, Complex 150, λ=351 nm) pumped the dye laser (Lambda Physik, Scanmate) with Coumarin 47 as a dye, which generated the laser beam of a wavelength turned around λ=450 nm. Then, the tuned dye laser beam pumped the BBO crystal in which the second harmonic radiation of a wavelength correspondingly tuned around λ=226 nm was generated. The 226-nm UV laser pulses of energy of 0.8-2 mJ and duration of about 20 ns were transformed into the form of the so-called laser sheet (width of 1 mm, height of 30-50 mm) which passed between the electrodes through the operating gas. The obtained results, presented in the form of images, which illustrated the two-dimensional distributions of NO molecule concentration in the non-thermal reactor, showed that the corona discharge-induced removal of NO molecules occurred not only in the vicinity of the plasma region formed by the corona discharge-induced removal of NO molecules occurred not only in the vicinity of the plasma region formed by the corona streamers and in the downstream region of the reactor but also in the upstream region of the reactor, i.e. before the flue gas simulator has entered the plasma region. This information obtained owing to the LIF technique, is important for the understanding of the plasma-chemistry processes responsible for NOx decomposition in non-thermal plasma reactors and for optimising their performance.

  1. Cross Sections for Ionization of Rare Gas Excimers by Electron Impact and Atomic and Molecular Processes in Excimer Lasers.

    DTIC Science & Technology

    1980-03-01

    6.1 Excimers and Exciplexes : Background 55 6.2 Rare Gas-Halide Lasers 58 6.3 Formation, Quenching and Absorption Processes for Rare Gas-Halides 60... exciplex such as KrF* and XeF* laser systems as well as in various types of gas discharges. They are also of fundamental significance in their own...collision processes contributing to the formation and quenching of the excited molecular states in exciplex (such as KrF ) and excimer (such as Xe2

  2. Neutron detection by scintillation of noble-gas excimers

    NASA Astrophysics Data System (ADS)

    McComb, Jacob Collin

    Neutron detection is a technique essential to homeland security, nuclear reactor instrumentation, neutron diffraction science, oil-well logging, particle physics and radiation safety. The current shortage of helium-3, the neutron absorber used in most gas-filled proportional counters, has created a strong incentive to develop alternate methods of neutron detection. Excimer-based neutron detection (END) provides an alternative with many attractive properties. Like proportional counters, END relies on the conversion of a neutron into energetic charged particles, through an exothermic capture reaction with a neutron absorbing nucleus (10B, 6Li, 3He). As charged particles from these reactions lose energy in a surrounding gas, they cause electron excitation and ionization. Whereas most gas-filled detectors collect ionized charge to form a signal, END depends on the formation of diatomic noble-gas excimers (Ar*2, Kr*2,Xe* 2) . Upon decaying, excimers emit far-ultraviolet (FUV) photons, which may be collected by a photomultiplier tube or other photon detector. This phenomenon provides a means of neutron detection with a number of advantages over traditional methods. This thesis investigates excimer scintillation yield from the heavy noble gases following the boron-neutron capture reaction in 10B thin-film targets. Additionally, the thesis examines noble-gas excimer lifetimes with relationship to gas type and gas pressure. Experimental data were collected both at the National Institute of Standards and Technology (NIST) Center for Neutron Research, and on a newly developed neutron beamline at the Maryland University Training Reactor. The components of the experiment were calibrated at NIST and the University of Maryland, using FUV synchrotron radiation, neutron imaging, and foil activation techniques, among others. Computer modeling was employed to simulate charged-particle transport and excimer photon emission within the experimental apparatus. The observed excimer scintillation yields from the 10B( n, alpha)7Li reaction are comparable to the yields of many liquid and solid neutron scintillators. Additionally, the observed slow triplet-state decay of neutron-capture-induced excimers may be used in a practical detector to discriminate neutron interactions from gamma-ray interactions. The results of these measurements and simulations will contribute to the development and optimization of a deployable neutron detector based on noble-gas excimer scintillation.

  3. Comparative study of excimer and erbium:YAG lasers for ablation of structural components of the knee

    NASA Astrophysics Data System (ADS)

    Vari, Sandor G.; Shi, Wei-Qiang; van der Veen, Maurits J.; Fishbein, Michael C.; Miller, J. M.; Papaioannou, Thanassis; Grundfest, Warren S.

    1991-05-01

    This study was designed to compare the efficiency and thermal effect of a 135 ns pulsed-stretched XeCl excimer laser (308 nm) and a free-running Erbium:YAG laser (2940 nm) with 200 microsecond(s) pulse duration for ablation of knee joint structures (hyaline and fibrous cartilage, tendon and bone). The radiant exposure used for tissue ablation ranged from 2 to 15 J/cm2 for the XeCl excimer and from 33 to 120 J/cm2 for Er:YAG. The excimer and Er:YAG lasers were operated at 4 and 5 Hz respectively. The ablative laser energy was delivered to tissue through fibers. Ablation rates of soft tissues (hyaline and fibrous cartilage, tendon) varied from 8.5 to 203 micrometers /pulse for excimer and from 8.2 to 273 micrometers /pulse for Er:YAG lasers. Ablation rates of soft tissues are linearly dependent on the radiant exposure. Within the range of parameters tested all the tissues except the bone could be rapidly ablated by both lasers. Bone ablation was much less efficient, requiring 15 J/cm2 and 110 J/cm2 radiant exposure for excimer and Er:YAG lasers to ablate 9.5 and 8.2 micrometers tissue per pulse. However, excimer laser ablation produced less thermal damage in the tissues studied compared to Er:YAG at the same laser parameters. The authors conclude that both lasers are capable of efficient knee joint tissue ablation. XeCl excimer laser requires an order of magnitude less energy than Er:YAG laser for comparable tissue ablation.

  4. Effectiveness of 308-nm Excimer Laser Therapy in Treating Alopecia Areata, Determined by Examining the Treated Sides of Selected Alopecic Patches.

    PubMed

    Byun, Ji Won; Moon, Jong Hyuk; Bang, Chan Yl; Shin, Jeonghyun; Choi, Gwang Seong

    2015-01-01

    Some studies have reported the use of 308-nm excimer laser therapy for treating alopecia areata (AA); however, the effectiveness of this therapy on a theoretical basis has not yet been comparatively analyzed. To determine the therapeutic effect of excimer laser therapy on AA. One alopecic patch was divided into control and treated sides in 10 patients with AA. Then, 308-nm excimer laser therapy was administered twice a week for 12 weeks. Photograph and phototrichogram analyses were performed. Photographic assessments by both dermatologists and individuals of the general population showed objective improvements after excimer laser therapy. On the treated side, the hair count and hair diameter had statistically increased after treatment. However, only the hair diameter was found to be significantly high in the treated half when it was compared with the control side. The 308-nm excimer laser has a therapeutic effect on AA, which is proven by photograph and phototrichogram analysis by a side-by-side comparison. © 2015 S. Karger AG, Basel.

  5. 308nm Excimer Laser in Dermatology

    PubMed Central

    Mehraban, Shadi

    2014-01-01

    308nm xenon-chloride excimer laser, a novel mode of phototherapy, is an ultraviolet B radiation system consisting of a noble gas and halide. The aim of this systematic review was to investigate the literature and summarize all the experiments, clinical trials and case reports on 308-nm excimer laser in dermatological disorders. 308-nm excimer laser has currently a verified efficacy in treating skin conditions such as vitiligo, psoriasis, atopic dermatitis, alopecia areata, allergic rhinitis, folliculitis, granuloma annulare, lichen planus, mycosis fungoides, palmoplantar pustulosis, pityriasis alba, CD30+ lympho proliferative disorder, leukoderma, prurigo nodularis, localized scleroderma and genital lichen sclerosus. Although the 308-nm excimer laser appears to act as a promising treatment modality in dermatology, further large-scale studies should be undertaken in order to fully affirm its safety profile considering the potential risk, however minimal, of malignancy, it may impose. PMID:25606333

  6. A comparative study of corneal incisions induced by diamond and steel knives and two ultraviolet radiations from an excimer laser.

    PubMed Central

    Marshall, J; Trokel, S; Rothery, S; Krueger, R R

    1986-01-01

    This paper reviews the potential role of excimer lasers in corneal surgery. The morphology of incisions induced by two wavelengths of excimer laser radiation, 193 nm and 248 nm, are compared with the morphology of incisions produced by diamond and steel knives. Analysis suggests that ablation induced by excimer laser results from highly localised photochemical reactions and that 193 nm is the optimal wavelength for surgery. The only significant complication of laser surgery is loss of endothelial cells when incisions are within 40 micron of Descemet's membrane. Images PMID:3013283

  7. Thermal characterization of poly(ethylene glycol)-poly(D,L-lactide) block copolymer micelles based on pyrene excimer formation.

    PubMed

    Jule, Eduardo; Yamamoto, Yuji; Thouvenin, Muriel; Nagasaki, Yukio; Kataoka, Kazunori

    2004-07-07

    Poly(ethylene glycol)--poly(D,L-lactide) (PEG-PDLLA) block copolymers were prepared by anionic ring-opening polymerization, resulting in block sizes effectively controlled by initial monomer/initiator ratios and low molecular weight distributions (<1.12). A pyrene derivative (1-pyrenyl carbonyl cyanide--Py) was conjugated to the end of the hydrophobic block (PDLLA) in a quantitative manner, with coupling efficiencies >95%. The so-obtained PEG-PDLLA-Py copolymers displayed fluorescent properties that were associated with the pyrene monomers, when placed in good solvents for both the hydrophilic and hydrophobic blocks. When placed in selective solvents, these copolymers self-assembled into micelles in the 30-nm range, also with low particle size distributions (<0.09), within which Py could be readily entrapped in the hydrophobic PDLLA core. Py entrapment resulted in the formation of excimers, as evident from fluorescence measurements. Observation of excimer formation/dissociation further conveyed information on the physicochemical properties of the core. Thermal characterization of these systems showed that an increase in the temperature resulted in changes in the properties of excimer fluorescence, an occurrence attributed to a higher mobility of the otherwise glassy PDLLA. This, in turn, greatly affected the inter-molecular distance between pyrene molecules, a crucial factor for excimer formation. The glass transition of the PDLLA block, approximately 38 degrees C, defined the onset for increasing chain mobility and whence excimer dissociation. Excimer fluorescence appeared to be time-dependent. Based on these observations, chain exchange processes were clearly evidenced through the time-dependent dissociation of excimers into unimers, a process that was influenced by changes in temperature.

  8. Use of Multiple Fluorescent Labels in Biological Sensing

    DTIC Science & Technology

    2006-05-01

    resulting in labels that are brighter and have longer Stokes shifts than the current standard; (B) to make excimer- and exciplex -forming probes for...2) to make excimer- and exciplex -forming probes for repetitive DNA sequences such as telomeres and centromeres, and to demonstrate them both...between fluorophores, and characterized unusual interactions, including water-soluble excimers and exciplexes . We investigated multiple ways to

  9. Excimer laser annealing for low-voltage power MOSFET

    NASA Astrophysics Data System (ADS)

    Chen, Yi; Okada, Tatsuya; Noguchi, Takashi; Mazzamuto, Fulvio; Huet, Karim

    2016-08-01

    Excimer laser annealing of lumped beam was performed to form the P-base junction for high-performance low-voltage-power MOSFET. An equivalent shallow-junction structure for the P-base junction with a uniform impurity distribution is realized by adopting excimer laser annealing (ELA). The impurity distribution in the P-base junction can be controlled precisely by the irradiated pulse energy density and the number of shots of excimer laser. High impurity activation for the shallow junction has been confirmed in the melted phase. The application of the laser annealing technology in the fabrication process of a practical low-voltage trench gate MOSFET was also examined.

  10. Excimer-laser-induced shock wave and its dependence on atmospheric environment

    NASA Astrophysics Data System (ADS)

    Krueger, Ronald R.; Krasinski, Jerzy S.; Radzewicz, Czeslaw

    1993-06-01

    High speed shadow photography is performed on excimer laser ablated porcine corneas and rubber stoppers to capture the excimer laser induced shock waves at various time delays between 40 and 320 nanoseconds. The shock waves in air, nitrogen, and helium are recorded by tangentially illuminating the ablated surface with a tunable dye laser, the XeCl excimer laser pulse. The excimer laser ablates the specimen and excites the dye laser, which is then passed through an optical delay line before illuminating the specimen. The shadow of the shock wave produced during ablation is then cast on a screen and photographed with a CCD video camera. The system is pulsed at 30 times per second to allow a video recording of the shock wave at a fixed time delay. We conclude that high energy acoustic waves and gaseous particles are liberated during excimer laser corneal ablation, and dissipate on a submicrosecond time scale. The velocity of their dissipation is dependent on the atmospheric environment and can be increased two-fold when the ablation is performed in a helium atmosphere. Therefore, local temperature increases due to the liberation of high energy gases may be reduced by using helium during corneal photoablation.

  11. Laser applications in advanced chip packaging

    NASA Astrophysics Data System (ADS)

    Müller, Dirk; Held, Andrew; Pätzel, Rainer; Clark, Dave; van Nunen, Joris

    2016-03-01

    While applications such as drilling μ-vias and laser direct imaging have been well established in the electronics industry, the mobile device industry's push for miniaturization is generating new demands for packaging technologies that allow for further reduction in feature size while reducing manufacturing cost. CO lasers have recently become available and their shorter wavelength allows for a smaller focus and drilling hole diameters down to 25μm whilst keeping the cost similar to CO2 lasers. Similarly, nanosecond UV lasers have gained significantly in power, become more reliable and lower in cost. On a separate front, the cost of ownership reduction for Excimer lasers has made this class of lasers attractive for structuring redistribution layers of IC substrates with feature sizes down to 2μm. Improvements in reliability and lower up-front cost for picosecond lasers is enabling applications that previously were only cost effective with mechanical means or long-pulsed lasers. We can now span the gamut from 100μm to 2μm for via drilling and can cost effectively structure redistribution layers with lasers instead of UV lamps or singulate packages with picosecond lasers.

  12. Overview on the high power excimer laser technology

    NASA Astrophysics Data System (ADS)

    Liu, Jingru

    2013-05-01

    High power excimer laser has essential applications in the fields of high energy density physics, inertial fusion energy and industry owing to its advantages such as short wavelength, high gain, wide bandwidth, energy scalable and repetition operating ability. This overview is aimed at an introduction and evaluation of enormous endeavor of the international high power excimer laser community in the last 30 years. The main technologies of high power excimer laser are reviewed, which include the pumping source technology, angular multiplexing and pulse compressing, beam-smoothing and homogenous irradiation, high efficiency and repetitive operation et al. A high power XeCl laser system developed in NINT of China is described in detail.

  13. New 223-nm excimer laser surgical system for photorefractive keratectomy

    NASA Astrophysics Data System (ADS)

    Bagaev, Sergei N.; Razhev, Alexander M.; Zhupikov, Andrey A.

    1999-02-01

    The using of KrCl (223 nm) excimer laser in ophthalmic devices for Photorefractive Keratectomy (PRK) and phototherapeutic Keratectomy (PTK) is offered. The structure and functions of a new surgical UV ophthalmic laser systems Medilex using ArF (193 nm) or KrCl (223 nm) excimer laser for corneal surgery are presented. The systems Medilex with the new optical delivery system is used for photoablative reprofiling of the cornea to correct refraction errors (myopia, hyperopia and astigmatism) and to treat a corneal pathologies. The use of the 223 nanometer laser is proposed to have advantages over the 193 nanometer laser. The results of application of the ophthalmic excimer laser systems Medilex for treatment of myopia are presented.

  14. Excimer laser photorefractive keratectomy for myopia: preliminary results at one year

    NASA Astrophysics Data System (ADS)

    Thompson, Keith P.; Waring, George O., III; Steinert, Roger; Durrie, Daniel S.; Gordon, Michael; Brint, Stephen F.

    1992-08-01

    Excimer laser photorefractive keratectomy (PRK) is presently under investigation for the correction of myopia. Two companies in the United States, Summit Technology (Waltham, Mass.) and VisX, Inc. (Sunnyvale, Calif.) have developed excimer laser delivery systems and are participating in an FDA study to determine the safety and efficacy of PRK. This is a preliminary report on the refractive and visual results of 51 of 100 eyes treated between October 10, 1990 and March 7, 1991 by the Summit Technology UV200LA excimer laser under the FDA Phase IIB FDA protocol one year after surgery. More detailed information on eight patients treated at Emory University Eye Center (Emory Subgroup) is also reported.

  15. Topographic steep central islands following excimer laser photorefractive keratectomy

    NASA Astrophysics Data System (ADS)

    Krueger, Ronald R.; McDonnell, Peter J.

    1994-06-01

    The purpose of this study is to demonstrate that topographic irregularities in the form of central islands of higher refractive power can be seen following excimer laser refractive surgery. We reviewed the computerized corneal topographic maps of 35 patients undergoing excimer laser PRK for compound myopic astigmatism or anisometropia from 8/91 to 8/93 at the USC/Doheny Eye Institute. The topographic maps were generated by the Computed Anatomy Corneal Modeling System, and central islands were defined as topographic areas of steepening of at least 3 diopters and 3 mm in diameter. A grading system was developed based on the presence of central islands during the postoperative period. Visually significant topographic steep central islands may be seen in over 50% of patients at 1 month following excimer laser PRK, and persist at 3 months in up to 24% of patients without nitrogen gas blowing. Loss of best corrected visual acuity or ghosting is associated with island formation, and may prolong visual rehabilitation after excimer laser PRK.

  16. Treatment of alopecia areata with the 308-nm xenon chloride excimer laser: case report of two successful treatments with the excimer laser.

    PubMed

    Gundogan, Cuneyt; Greve, Bärbel; Raulin, Christian

    2004-01-01

    Alopecia areata is a common disease of unknown etiology; it causes significant cosmetic and psycho-social distress for most of the people it affects. We report on an innovative form of treatment in two patients with typical alopecia areata on the capillitium. We successfully treated two patients whose alopecia areata had worsened progressively for 3 and 14 weeks. The treatment involved the use of a 308 nm xenon chloride excimer laser (dosage 300-2,300 mJ/cm(2) per session). After 11 and 12 sessions within a 9-week and 11-week period, the entire affected focus showed homogenous and thick regrowth. No relapse was observed during the follow-up period of 5 and 18 months. The use of the excimer laser is an effective, elegant, and safe means of treatment and has good tolerability. Analogous to topical treatment of alopecia areata, the immunosuppressive mechanism of the excimer laser can be interpreted as an induction of T-cell apoptosis. This new means of treatment has yet to be discussed in medical literature. Further studies with greater numbers are needed to assess its potential more precisely and evaluate the excimer laser in treating alopecia areata. Copyright 2004 Wiley-Liss, Inc.

  17. Average power scaling of UV excimer lasers drives flat panel display and lidar applications

    NASA Astrophysics Data System (ADS)

    Herbst, Ludolf; Delmdahl, Ralph F.; Paetzel, Rainer

    2012-03-01

    Average power scaling of 308nm excimer lasers has followed an evolutionary path over the last two decades driven by diverse industrial UV laser microprocessing markets. Recently, a new dual-oscillator and beam management concept for high-average power upscaling of excimer lasers has been realized, for the first time enabling as much as 1.2kW of stabilized UV-laser average output power at a UV wavelength of 308nm. The new dual-oscillator concept enables low temperature polysilicon (LTPS) fabrication to be extended to generation six glass substrates. This is essential in terms of a more economic high-volume manufacturing of flat panel displays for the soaring smartphone and tablet PC markets. Similarly, the cost-effective production of flexible displays is driven by 308nm excimer laser power scaling. Flexible displays have enormous commercial potential and can largely use the same production equipment as is used for rigid display manufacturing. Moreover, higher average output power of 308nm excimer lasers aids reducing measurement time and improving the signal-to-noise ratio in the worldwide network of high altitude Raman lidar stations. The availability of kW-class 308nm excimer lasers has the potential to take LIDAR backscattering signal strength and achievable altitude to new levels.

  18. Investigation on gas medium parameters for an ArF excimer laser through orthogonal experimental design

    NASA Astrophysics Data System (ADS)

    Song, Xingliang; Sha, Pengfei; Fan, Yuanyuan; Jiang, R.; Zhao, Jiangshan; Zhou, Yi; Yang, Junhong; Xiong, Guangliang; Wang, Yu

    2018-02-01

    Due to complex kinetics of formation and loss mechanisms, such as ion-ion recombination reaction, neutral species harpoon reaction, excited state quenching and photon absorption, as well as their interactions, the performance behavior of different laser gas medium parameters for excimer laser varies greatly. Therefore, the effects of gas composition and total gas pressure on excimer laser performance attract continual research studies. In this work, orthogonal experimental design (OED) is used to investigate quantitative and qualitative correlations between output laser energy characteristics and gas medium parameters for an ArF excimer laser with plano-plano optical resonator operation. Optimized output laser energy with good pulse to pulse stability can be obtained effectively by proper selection of the gas medium parameters, which makes the most of the ArF excimer laser device. Simple and efficient method for gas medium optimization is proposed and demonstrated experimentally, which provides a global and systematic solution. By detailed statistical analysis, the significance sequence of relevant parameter factors and the optimized composition for gas medium parameters are obtained. Compared with conventional route of varying single gas parameter factor sequentially, this paper presents a more comprehensive way of considering multivariables simultaneously, which seems promising in striking an appropriate balance among various complicated parameters for power scaling study of an excimer laser.

  19. Excimer-based peptide beacons: a convenient experimental approach for monitoring polypeptide-protein and polypeptide-oligonucleotide interactions.

    PubMed

    Oh, Kenneth J; Cash, Kevin J; Plaxco, Kevin W

    2006-11-01

    While protein-polypeptide and nucleic acid-polypeptide interactions are of significant experimental interest, quantitative methods for the characterization of such interactions are often cumbersome. Here we described a relatively simple means of optically monitoring such interactions using excimer-based peptide beacons (PBs). The design of PBs is based on the observation that, whereas short peptides are almost invariably unfolded and highly dynamic, they become rigid when complexed with macromolecular targets. Using this binding-induced folding to segregate two pyrene moieties and therefore inhibit excimer formation, we have produced PBs directed against both anti-HIV antibodies and the retroviral transactive response (TAR) RNA hairpin. For both polypeptides, target recognition is accompanied by a roughly 2-fold decrease in excimer emission, thus allowing the detection of their respective targets at concentrations of a few nanomolar. Because excimer emission requires the formation of a tight, precisely oriented pyrene dimer, even relatively trivial binding-induced segregation reduces fluorescence significantly. This suggests that the PB approach will be suitable for monitoring a wide range of peptide-macromolecule recognition events. Moreover, the synthesis of excimer-based PBs utilizes commercially available modified pyrenes in a simple and well-established protocol, making the approach well suited for routine laboratory applications.

  20. Excimer laser debridement of necrotic erosions of skin without collateral damage

    NASA Astrophysics Data System (ADS)

    Wynne, James J.; Felsenstein, Jerome M.; Trzcinski, Robert; Zupanski-Nielsen, Donna; Connors, Daniel P.

    2011-07-01

    Pulsed ArF excimer laser radiation at 6.4 eV, at fluence exceeding the ablation threshold, will debride burn eschar and other dry necrotic erosions of the skin. Debridement will cease when sufficiently moist viable tissue is exposed, due to absorption by aqueous chloride ions (Cl-) through the non-thermal process of electron photodetachment, thereby inhibiting collateral damage to the viable tissue. ArF excimer laser radiation debrides/ablates ~1 micron of tissue with each pulse. While this provides great precision in controlling the depth of debridement, the process is relatively time-consuming. In contrast, XeCl excimer laser radiation debrides ~8 microns of tissue with each pulse. However the 4.0 eV photon energy of the XeCl excimer laser is insufficient to photodetach an electron from a Cl- ion, so blood or saline will not inhibit debridement. Consequently, a practical laser debridement system should incorporate both lasers, used in sequence. First, the XeCl excimer laser would be used for accelerated debridement. When the necrotic tissue is thinned to a predetermined thickness, the ArF excimer laser would be used for very precise and well-controlled debridement, removing ultra-thin layers of material with each pulse. Clearly, the use of the ArF laser is very desirable when debriding very close to the interface between necrotic tissue and viable tissue, where the overall speed of debridement need not be so rapid and collateral damage to viable tissue is undesirable. Such tissue will be sterile and ready for further treatment, such as a wound dressing and/or a skin graft.

  1. A review of protocols for 308 nm excimer laser phototherapy in psoriasis.

    PubMed

    Mudigonda, Tejaswi; Dabade, Tushar S; Feldman, Steven R

    2012-01-01

    308 nm excimer laser phototherapy is efficacious in the treatment of localized psoriasis. Different approaches regarding dose fluency, number of treatments, and maintenance have been utilized, and there is yet to be a consensus on standard protocol. To characterize treatment parameters for 308 nm excimer laser phototherapy. We performed a PubMed search for studies describing excimer laser treatment protocol with particular attention to dosage determination, dose adjustment, dose fluency, number of treatments, and maintenance. Seven prospective studies were found describing the excimer efficacy for psoriasis. All studies determined the initial treatment dose using either the minimal erythema dose (MED) or induration. Fluency ranged from 0.5 MED (low) to 16 MED (high); one study demonstrated that medium to high fluencies yielded better improvement in fewer number of treatments. Fluency adjustments during the course of treatment were important to minimize phototherapy-associated side effects. The use of higher fluencies was reported to result in higher occurrences of blistering. One study implemented a maintenance tapering of dose-frequency phase to better manage psoriasis flare-ups. The 308 nm excimer laser is an effective therapy for psoriasis regardless of the method used to determine initial dosage, dose fluency, or number of treatments. As its usage as a targeted monotherapy increases, future trials should consider evaluating and modifying these parameters to determine the most optimal management of localized psoriasis. Based on our reviewed studies, there is no consensus for a single excimer laser therapy protocol and as a result, patient preferences should continue to be an important consideration for phototherapy regimen planning.

  2. The Excimer Laser: Its Impact on Science and Industry

    NASA Astrophysics Data System (ADS)

    Basting, Dirk

    2010-03-01

    After the laser was demonstrated in 1960, 15 years were required to develop a practical method for extending laser emission into the UV: the Excimer laser. This historical review will describe the challenges with the new medium and provide an insight into the technological achievements. In the transition from Science to Industry it will be shown how start-ups successfully commercialized laboratory prototypes. The pioneers in this rapidly expanding field will be identified and the influence of government-funded research as well as the role of venture capital will be discussed. In scientific applications, the fields of photochemistry and material research were particularly stimulated by the advent of a reliable UV light source. Numerous industrial applications and worldwide research in novel applications were fueled In the early and mid 80's by progress in excimer laser performance and technology. The discovery of ablative photocomposition of polymer materials by Srinivasan at IBM opened the door to a multitude of important excimer applications. Micromachining with extreme precision with an excimer laser enabled the success of the inkjet printer business. Biological materials such as the human cornea can also be ``machined'' at 193nm, as proposed in 1983 by Trokel and Srinivasan. This provided the foundation of a new medical technology and an industry relying on the excimer laser to perform refractive surgery to correct vision Today, by far the largest use of the excimer laser is in photolithography to manufacture semiconductor chips, an application discovered by Jain at IBM in the early 80's. Moore's law of shrinking the size of the structure to multiply the number of transistors on a chip could not have held true for so long without the deep UV excimer laser as a light source. The presentation will conclude with comments on the most recent applications and latest market trends.

  3. Regeneration of defective epithelial basement membrane and restoration of corneal transparency

    PubMed Central

    Marino, Gustavo K.; Santhiago, Marcony R.; Santhanam, Abirami; Torricelli, Andre A. M.; Wilson, Steven E.

    2018-01-01

    PURPOSE To study regeneration of the normal ultrastructure of the epithelial basement membrane (EBM) in rabbit corneas that had -9D photorefractive keratectomy (PRK) and developed late haze (fibrosis) with restoration of transparency over one to four months after surgery and in corneas that had incisional wounds. METHODS Twenty-four rabbits had one of their eyes included into one of the two procedure groups (-9D PRK or nearly full-thickness incisional wounds), while the opposite eye serving as unwounded controls. All corneas were evaluated with slit lamp photos, transmission electron microscopy and immunohistochemistry for the myofibroblast marker alpha-smooth muscle actin and collagen type III. RESULTS In the ‘-9D PRK group’, corneas at one month after surgery had dense corneal haze and no evidence of regenerated EBM ultrastructure. By two months after surgery, however, small areas of stromal clearing began to appear within the confluent opacity (lacunae), and these corresponded to small islands of normally-regenerated EBM detected within larger area of the excimer laser-ablated zone with no evidence of normal EBM. By four months after surgery, the EBM was fully-regenerated and the corneal transparency was completely restored to the ablated zone. In the ‘Incisional wound group’, the two dense, linear corneal opacities were observed at one month after surgery and progressively faded by two and three months after surgery. The EBM ultrastructure was fully regenerated at the site of the incisions, including around epithelial plugs that extended into the stroma, by one month after surgery in all eyes. CONCLUSIONS In the rabbit model, spontaneous resolution of corneal fibrosis (haze) after high correction PRK is triggered by regeneration of EBM with normal ultrastructure in the excimer laser- ablated zone. Conversely, incisional wounds heal in rabbit corneas without the development of myofibroblasts because the EBM regenerates normally by one month after surgery. PMID:28486725

  4. Excimer-monomer switch: a reaction-based approach for selective detection of fluoride.

    PubMed

    Song, Qiao; Bamesberger, Angela; Yang, Lingyun; Houtwed, Haley; Cao, Haishi

    2014-07-21

    A N-aryl-1,8-naphthalimide based sensor (ES-1) bearing a trimethylsilyl ether has been synthesized by a two-step reaction for quantitative detection of fluoride (F(-)). ES-1 exhibited monomer/excimer emissions at 410 and 524 nm respectively in CH2Cl2. In the presence of F(-), the desilylation of trimethylsilyl ether caused decay of the excimer emission as well as enhancement of the monomer emission to give a ratiometric signal. The fluoride-triggered desilylation showed a high reaction rate and high affinity to F(-) over nine other interfering anions. ES-1 provided a novel fluorescence assay based on excimer-monomer switch of N-aryl-1,8-naphthalimide to quantitatively measure F(-) with a detection limit of 0.133 ppm.

  5. Controlled study of excimer and pulsed dye lasers in the treatment of psoriasis.

    PubMed

    Taibjee, S M; Cheung, S-T; Laube, S; Lanigan, S W

    2005-11-01

    The excimer laser delivers high energy monochromatic ultraviolet (UV) B at 308 nm. Advantages over conventional UV sources include targeting of lesional skin, reducing cumulative dose and inducing faster clearance. Studies of the pulsed dye laser (PDL) in psoriasis report between 57% and 82% response rates; remission may extend to 15 months. To our knowledge, this is the first study assessing both excimer and PDL in psoriasis. We conducted a within-patient controlled prospective trial of treatment of localized plaque psoriasis. Twenty-two adult patients, mean Psoriasis Area and Severity Index 7.1, were recruited. Fifteen patients completed the full treatment, of which 13 were followed up to 1 year. Two selected plaques were treated with excimer twice weekly and V Beam PDL, pretreated with salicylic acid (SA), every 4 weeks, respectively. Two additional plaques, treated with SA alone or untreated, served as controls. The primary outcome measures were: (i) changes in plaque-modified Psoriasis Activity and Severity Index (PSI) scores from baseline to end of treatment; (ii) clinical response to treatment (CR(T)), assessed by serial photographs; (iii) percentage of plaques clear at the end of treatment; and (iv) percentage of plaques clear at 1-year follow-up. The secondary outcome measures were: (i) number of laser treatments to clearance; (ii) time to relapse; (iii) frequency of side-effects; and (iv) qualitative observations with SIAscope. The mean improvement in PSI was 4.7 (SD 2.1) with excimer and 2.7 (SD 2.4) with PDL. PSI improvement was significantly greater in excimer than PDL (P = 0.003) or both control plaques (P < 0.001). CR(T) indicated 13 patients responded best with excimer, two patients best with PDL, and in seven patients there was no difference between the two lasers. CR(T) was significantly greater for excimer than PDL (P = 0.003) or both controls (P < 0.001). CR(T) was also significantly greater for PDL than SA alone (P = 0.004) or untreated control (P =0.002). Nine (41%) patients cleared with excimer, after mean 8.7, median 10 weeks treatment. Seven of these nine patients were followed up to 1 year; four remained clear, two relapsed at 1 month, and one at 6 months. Six (27%) patients cleared with PDL, after mean 3.3, median four treatments. All six patients were followed up to 1 year; four remained clear, one relapsed at 4 months and one at 9 months. Despite common side-effects including blistering and hyperpigmentation, patient satisfaction was high. Serial images obtained with the SIAscope during treatment indicated different mechanisms of action of the two lasers. Excimer and V Beam PDL are useful treatments for plaque psoriasis. Although the excimer appears to be on average more efficacious, a subset of patients may respond better to PDL. Long-term remission is achievable with both lasers.

  6. Dual Laser-Assisted Lamellar Anterior Keratoplasty with Tophat Graft: A Laboratory Study

    PubMed Central

    Cleary, Catherine; Song, Jonathan C.; Tang, Maolong; Li, Yan; Liu, Ying; Yiu, Samuel; Huang, David

    2011-01-01

    Objectives To develop a dual laser-assisted lamellar anterior keratoplasty (LALAK) technique, using excimer and femtosecond lasers to perform surgery on eye-bank eyes. Methods First we compared corneal stromal surfaces produced by (1) deep excimer ablation, (2) femtosecond lamellar cuts, and (3) manual dissection, and evaluated the effect of excimer laser smoothing with fluid masking on each surface. Masked observers graded scanning electron microscopy (SEM) images on a 5-point roughness scale. Then we performed a 6-mm diameter excimer laser phototherapeutic keratectomy (PTK) ablation to a residual bed thickness of 200μm, followed by laser smoothing. We used the femtosecond laser to cut donors in a modified top-hat design with a thin tapered brim, which fitted into a manually dissected circumferential pocket at the base of the recipient bed. Fourier-domain optical coherence tomography (OCT) was used to measure corneal pachymetry and evaluate graft fit. Results Deep excimer ablation with smoothing (n=4) produced a significantly (p<0.05) smoother surface (grade=3.5) than deep excimer alone (n=4, grade=3.8) or manual dissection with (n=1, grade=3.8) and without smoothing (n=1, grade=4.8). Deep femtosecond cuts (n=2) produced macroscopic concentric ridges on the stromal surface. Experimental LALAK was performed on 4 recipients prepared by deep excimer ablation and 4 donors cut with the femtosecond laser. After suturing good peripheral graft-host match was observed on FD-OCT imaging. Conclusion These preliminary studies show that the LALAK technique permits improved interface smoothness and graft edge matching. Clinical trials are needed to determine whether these improvements can translate to better vision. PMID:22378114

  7. Acute effects of pulsed-laser irradiation on the arterial wall

    NASA Astrophysics Data System (ADS)

    Nakamura, Fumitaka; Kvasnicka, Jan; Lu, Hanjiang; Geschwind, Herbert J.; Levame, Micheline; Bousbaa, Hassan; Lange, Francoise

    1992-08-01

    Pulsed laser coronary angioplasty with an excimer or a holmium-yttrium-aluminum-garnet (Ho:YAG) laser may become an alternative treatment for patients with coronary artery disease. However, little is known about its acute consequences on the normal arterial wall. This study was designed to examine the acute histologic consequences of these two pulsed lasers on the arterial wall of normal iliac arteries in rabbits. Irradiation with each laser was performed in 15 normal iliac sites on eight male New Zealand white rabbits. The excimer laser was operated at 308 nm, 25 Hz, 50 mJ/mm2/pulse, and 135 nsec/pulse and the Ho:YAG laser was operated at 2.1 micrometers , 3/5 Hz, 400 mJ/pulse, and 250 microsecond(s) ec/pulse. The excimer and Ho:YAG laser were coupled into a multifiber wire-guided catheter of 1.4 and 1.5 mm diameter, respectively. The sites irradiated with excimer or Ho:YAG laser had the same kinds of histologic features, consisting of exfoliation of the endothelium, disorganization of internal elastic lamina, localized necrosis of vascular smooth muscle cells, and fissures in the medial layer. However, the sites irradiated with excimer laser had lower grading scores than those irradiated with Ho:YAG laser (p < 0.05). Laser irradiation with excimer or Ho:YAG laser of normal arteries results in localized mechanical vascular injury.

  8. Clinical efficacy of flumetasone/salicylic acid ointment combined with 308-nm excimer laser for treatment of psoriasis vulgaris.

    PubMed

    Dong, Jie; He, Yanling; Zhang, Xiuying; Wang, Yixuan; Tian, Yongjing; Wang, Jie

    2012-06-01

    To compare the clinical efficacy and safety of combining flumetasone ointment with 308-nm excimer laser therapy vs. 308-nm excimer laser monotherapy for the treatment of psoriasis vulgaris. Forty patients with psoriasis vulgaris were recruited; 20 were treated with flumetasone ointment plus 308-nm excimer laser therapy, and the other 20 received only excimer laser monotherapy. The flumetasone ointment was applied topically twice a day, and laser treatments were scheduled twice weekly for a total of 10 treatments. Clinical efficacy was evaluated in a blinded manner by two independent physicians using photographs taken before and after treatment. Of the 40 patients who received and completed the entire course of therapy, the psoriasis area and severity index score was improved by 82.51 ± 11.24% and 72.01 ± 20.94% in the combination group and laser group, respectively (P > 0.05), and the average cumulative dose was 5.06 ± 2.20 j/cm(2) in the combination group and 7.75 ± 2.25 j/cm(2) in the laser-only group, respectively (P < 0.05). The clinical data suggest that combination treatment using flumetasone ointment and a 308-nm excimer laser is superior to laser monotherapy for treatment of psoriasis vulgaris. The combination therapy can increase effectiveness and decrease the total laser dose, thus potentially reducing side effects. © 2012 John Wiley & Sons A/S.

  9. ArF excimer laser debrides burns without destruction of viable tissue: A pilot study.

    PubMed

    Prasad, Atulya; Sawicka, Katarzyna M; Pablo, Kelly B; Macri, Lauren K; Felsenstein, Jerome; Wynne, James J; Clark, Richard A F

    2018-05-01

    Recent evidence indicates that early removal of eschar by tangential debridement can promote healing. Laser debridement can be used for debridement of areas that prove challenging for debridement using tangential excision. In particular, irradiation with an ArF excimer laser ablates desiccated eschar and is self-terminating, preserving hydrated or viable tissue. Thermal burns were created on the flanks of two outbred, female Yorkshire pigs using aluminum bars heated to 70°C and applied for different lengths of time. Three days after injury, burns were debrided using an ArF excimer laser (193nm). Tissue was harvested immediately after debridement and 7days after debridement (10days after burn). Data from a pilot study demonstrates that ArF excimer laser irradiation removes burn eschar and promotes healing at 10days after burn. ArF excimer laser debridement is self-terminating and preserves underlying and adjacent perfused tissue. Potentially, this modality would be ideal for the complex curvilinear structures of the body. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.

  10. Collagen crosslinking for ectasia following PRK performed in excimer laser-assisted keratoplasty for keratoconus.

    PubMed

    Spadea, Leopoldo

    2012-01-01

    To report the results of corneal collagen crosslinking (CXL) in a patient with corneal ectasia developed after excimer laser-assisted lamellar keratoplasty for keratoconus and a secondary photorefractive keratectomy (PRK) for residual refractive error. A 33-year-old woman, who had originally been treated for keratoconus in the right eye by excimer laser-assisted lamellar keratoplasty, subsequently had her residual ametropia treated by topographically guided, transepithelial excimer laser PRK. Five years after PRK, the patient developed corneal ectasia showing concomitant visual changes of best spectacle-corrected visual acuity (BSCVA) reduced to 20/33 with a refraction of -6.00 +6.00 × 30. The minimum corneal thickness at the ectasia apex was 406 µm. A treatment of riboflavin-UVA-induced corneal CXL was performed on the right eye. Two years after the CXL treatment, the right eye improved to 20/20 BSCVA with a refraction of plano +1.00 × 50 while exhibiting a clear lamellar graft. Corneal CXL provided safe and effective management of ectasia developed after excimer laser-assisted lamellar keratoplasty and PRK.

  11. Changing profile of excimer laser coronary angioplasty: refinements in catheters

    NASA Astrophysics Data System (ADS)

    Bittl, John A.

    1994-07-01

    During more than five years of investigation with excimer laser angioplasty, several changes have been made in patient selection and laser catheters. It is unclear, however, whether these changes have improved the outcome of excimer laser angioplasty. A total of 2041 patients underwent treatment with excimer laser coronary angioplasty for 2324 lesions with clinical success in 89%, ischemic complications in 7.5%, and vessel perforation in 2.1%. When the entire 5-year period of investigation was divided into four discrete phases, as defined by the successive release of improved laser catheters (prototype, flexible, extremely flexible, and eccentric), clinical success was seen to improve from 86% to 95% (p<0.001) despite the increased incidence of advanced age (pequals0.01) and unstable angina (p<0.001). Multivariable analysis identified improved laser catheters, saphenous vein graft lesions, and unclarified stenoses as predictors of favorable outcome. Operator experience was associated with decreased complications. Reduced catheter size relative to vessel size was associated with decreased risk of vessel perforation. Thus, refinements in patient selection and in laser technique have been associated with enhanced safety and efficacy of excimer laser angioplasty.

  12. Carbazole-based BODIPYs with ethynyl substituents at the boron center: solid-state excimer fluorescence in the VIS/NIR region.

    PubMed

    Maeda, Chihiro; Nagahata, Keiji; Ema, Tadashi

    2017-09-26

    Carbazole-based BODIPYs 1-6 with several different substituents at the boron atom site were synthesized. These dyes fluoresced in the solid state, and 3a with phenylethynyl groups exhibited a red-shifted and broad fluorescence spectrum, which suggested an excimer emission. Its derivatives 3b-n were synthesized, and the relationship between the solid-state emission and crystal packing was investigated. The X-ray crystal structures revealed cofacial dimers that might form excimers. From the structural optimization results, we found that the introduction of mesityl groups hindered intermolecular access and led to reduced interactions between the dimers. In addition, the red-shifted excimer fluorescence suppressed self-absorption, and dyes with ethynyl groups showed solid-state fluorescence in the vis/NIR region.

  13. Optical clearing of skin using flash lamp-induced enhancement of epidermal permeability.

    PubMed

    Tuchin, V V; Altshuler, G B; Gavrilova, A A; Pravdin, A B; Tabatadze, D; Childs, J; Yaroslavsky, I V

    2006-10-01

    Strong light scattering in skin prevents precise targeting of optical energy in therapeutic and diagnostic applications. Optical immersion based on matching refractive index of scattering centers with that of surrounding matter through introduction of an exogenous index-matching agent can alleviate the problem. However, slow diffusion of the index-matching agent through skin barrier makes practical implementation of this approach difficult. We propose a method of accelerating penetration of the index-matching compounds by enhancing skin permeability through creating a lattice of micro-zones (islets) of limited thermal damage in the stratum corneum (SC). A flash lamp (intense pulsed light) system and an island mask with a pattern of absorbing centers (center size approximately 75-120 microm, lattice pitch approximately 450-500 microm) were used to create the lattice of islets of damage (LID). Index-matching agents, such as glucose solution, propylene glycol solution, and glycerol solution, were applied. Experimental results of optical clearing ex vivo rat and pig skin, and ex vivo and in vivo human skin are presented. Optical transmission spectra of the skin samples with LID were measured during some 2 hours after application of index-matching chemical agents. In order to assess and compare the clearing rate under different treatment and clearing agents we calculated the quantity that we call "relative transmittance": T(rel) = I(t)(lambda)/I(0)(lambda), were I(t)(lambda) is the intensity measured at elapsed time t. The dynamics of relative transmittance of skin samples at 470 and 650 nm shows that the implementation of limited thermal damage technique leads to a 3-10-fold increase of optical clearing (rise of transmittance) rate compared to the results obtained when the samples were treated with high-intensity light pulses but without the use of island damage mask (IDM). It was observed from the plotted spectra of relative transmittance that the maximum increase of transmitted light intensity has been obtained with glucose solution as a clearing agent. Noteworthy is the difference in the trend of spectral curves: relative transmittance spectrum for glycerol reveals, on the whole, a greater slope which may be indicative of higher extent of index matching between the scattering centers and base material for this index-matching agent. Under the transillumination of the skin sample by the wide flat beam the more effective clearing (the increase of transmitted intensity) is attained within the hemoglobin absorption bands; with the narrow quasi-collimated beam the higher relative transmittance was observed over the intervals of minimum absorption. The use of specially designed island mask combined with non-laser intensive pulse irradiation produces a lattice of islands of limited thermal damage in SC that substantially enhances the penetration rate of topically applied index-matching agents. The suggested technique gave comparable magnitudes of clearing dynamics enhancement for glucose solution, glycerol solution, and propylene glycol solution applied to mammalian skin.

  14. Five-Body Cluster Structure of the Double-{Lambda} Hypernucleus {sub {Lambda}{Lambda}}{sup 11}Be

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hiyama, E.; Kamimura, M.; Yamamoto, Y.

    2010-05-28

    Energy levels of the double {Lambda} hypernucleus, {sub {Lambda}{Lambda}}{sup 11}Be are calculated within the framework of a {alpha}{alpha}n{Lambda}{Lambda} five-body model. Interactions between constituent particles are determined so as to reproduce reasonably the observed low-energy properties of the {alpha}{alpha}, {alpha}{alpha}n nuclei and the existing data for {Lambda}-binding energies of the {alpha}{Lambda}, {alpha}{alpha}{Lambda}, {alpha}n{Lambda}, and {alpha}{alpha}n{Lambda} systems. An effective {Lambda}{Lambda} interaction is constructed so as to reproduce, within the {alpha}{Lambda}{Lambda} three-body model, the B{sub {Lambda}{Lambda}}of {sub {Lambda}{Lambda}}{sup 6}He, which was extracted from the emulsion experiment, the NAGARA event. With no adjustable parameters for the {alpha}{alpha}n{Lambda}{Lambda} system, B{sub {Lambda}{Lambda}}of the ground and boundmore » excited states of {sub {Lambda}{Lambda}}{sup 11}Be are calculated with the Gaussian expansion method. The Hida event, recently observed at KEK-E373 experiment, is interpreted as an observation of the ground state of the {sub {Lambda}{Lambda}}{sup 11}Be.« less

  15. Study of {Lambda}-{Lambda} oscillation in quantum coherent {Lambda}{Lambda} by using J/{psi}{yields}{Lambda}{Lambda} decay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kang Xianwei; Department of Physics, Henan Normal University, Xinxiang 453007; Li Haibo

    2010-03-01

    We discuss the possibility of searching for the {Lambda}-{Lambda} oscillations for coherent {Lambda}{Lambda} production in the J/{psi}{yields}{Lambda}{Lambda} decay process. The sensitivity of measurement of {Lambda}-{Lambda} oscillation in the external field at BES-III experiment is considered. These considerations indicate an alternative way to probe the {Delta}B=2 amplitude in addition to neutron oscillation experiments. Both coherent and time-dependent information can be used to extract the {Lambda}-{Lambda} oscillation parameter. With one year's luminosity at BES-III, we can set an upper limit of {delta}m{sub {Lambda}{Lambda}<}10{sup -15} MeV at 90% confidence level, corresponding to about 10{sup -6} s of {Lambda}-{Lambda} oscillation time.

  16. Keratorefractive procedures

    NASA Astrophysics Data System (ADS)

    Seiler, Theo

    1991-11-01

    Two laser types are going to find a place in refractive surgery of the cornea: the excimer laser (193 nm) and mid-infrared YAG lasers, such as Ho:YAG (2.1 micrometers ) and Er:YAG (2.94 micrometers ). Whereas the excimer laser used for photorefractive keratectomy (PRK) and phototherapeutic keratectomy (PTK) is currently studied in clinical trials, Ho:YAG and Er:YAG lasers are still in the state of preclinical evaluation. For myopic corrections excimer laser PRK has shown to be safe and effective in the range up to -7.0 D. The results compare favorably with conventional procedures such as radial keratotomy. Complications are rare. Hyperopic and astigmatic corrections using the Ho:YAG laser (HOT) are effective, but safety and stability has yet to be proven. Er:YAG laser photoablation yields a healing response in animal eyes similar to the excimer laser.

  17. Excimer laser processing of backside-illuminated CCDS

    NASA Technical Reports Server (NTRS)

    Russell, S. D.

    1993-01-01

    An excimer laser is used to activate previously implanted dopants on the backside of a backside-illuminated CCD. The controlled ion implantation of the backside and subsequent thin layer heating and recrystallization by the short wavelength pulsed excimer laser simultaneously activates the dopant and anneals out implant damage. This improves the dark current response, repairs defective pixels and improves spectral response. This process heats a very thin layer of the material to high temperatures on a nanosecond time scale while the bulk of the delicate CCD substrate remains at low temperature. Excimer laser processing backside-illuminated CCD's enables salvage and utilization of otherwise nonfunctional components by bringing their dark current response to within an acceptable range. This process is particularly useful for solid state imaging detectors used in commercial, scientific and government applications requiring a wide spectral response and low light level detection.

  18. 308-nm excimer laser for the treatment of alopecia areata.

    PubMed

    Al-Mutairi, Nawaf

    2007-12-01

    Alopecia areata is loss of hair from localized or diffuse areas of hair-bearing area of the skin. Recently there are reports of efficacy of the 308-nm excimer radiation for this condition. To study the effect of the 308-nm excimer laser in the treatment of alopecia areata. Eighteen patients with 42 recalcitrant patches (including 1 adult with alopecia totalis) were enrolled in this study. The lesions were treated with the 308-nm excimer laser twice a week for a period of 12 weeks; one lesion on each patient was left as a control for comparison. There were 7 males and 11 females in this study. Regrowth of hair was observed in 17 (41.5%) patches. Thirteen of the 18 lesions in scalp showed a complete regrowth of hair. The extremity regions failed to show a response. Atopic diatheses had an unfavorable effect on the outcome in our patients. The 308-nm excimer laser is an effective therapeutic option for patchy alopecia areata of the scalp and for some cases with patchy alopecia areata of the beard area. It does not work for patchy alopecia areata of the extremities.

  19. Development of compact excimer lasers for remote sensing

    NASA Technical Reports Server (NTRS)

    Laudenslager, J. B.; Mcdermid, I. S.; Pacala, T. J.

    1983-01-01

    The capabilities of excimer lasers for remote sensing applications are illustrated in a discussion of the development of a compact tunable XeCl excimer laser for the detection of atmospheric OH radicals. Following a brief review of the operating principles and advantages of excimer lasers, measurements of the wavelength dependence of the net small signal gain coefficient of a discharge excited XeCl laser are presented which demonstrate the overlap of several absorption lines of the A-X(0,0) transition of OH near 308 nm with the wavelengths of the XeCl laser. A range of continuous narrow bandwidth tunability of from 307.6 to 308.4 nm with only a 30 percent variation in output is reported for an XeCl laser used as a double-pass amplifier for a frequency-doubled dye laser, and measurements demonstrating the detection of laser-induced fluorescence from OH in a methane-oxygen flame are also noted. The design of an oscillator-amplifier excimer system comprising a corona-preionized, transverse-discharge oscillator and amplifier is then presented. Output energies of 12-15 mJ have been achieved in the regions where injection locking was established, with energies of 8-10 mJ elsewhere.

  20. Enabling laser applications in microelectronics manufacturing

    NASA Astrophysics Data System (ADS)

    Delmdahl, Ralph; Brune, Jan; Fechner, Burkhard; Senczuk, Rolf

    2016-02-01

    In this experimental study, we report on high-pulse-energy excimer laser drilling into high-performance build-up films which are pivotal in microelectronics manufacturing. Build-up materials ABF-GX13 from Ajinomoto as well as ZS-100 from Zeon Corporation are evaluated with respect to their viability for economic excimer laser-based micro-via formation. Excimer laser mask imaging projection at laser wavelengths of 193, 248 and 308 nm is employed to generate matrices of smaller micro-vias with different diameters and via pitches. High drilling quality is achievable for all excimer laser wavelengths with the fastest ablation rates measured in the case of 248 and 308 nm wavelengths. The presence of glass fillers in build-up films as in the ABF-GX13 material poses some limitations to the minimum achievable via diameter. However, surprisingly good drilling results are obtainable as long as the filler dimensions are well below the diameter of the micro-vias. Sidewall angles of vias are controllable by adjusting the laser energy density and pulse number. In this work, the structuring capabilities of excimer lasers in build-up films as to taper angle variations, attainable via diameters, edge-stop behavior and ablation rates will be elucidated.

  1. Excimer laser therapy and narrowband ultraviolet B therapy for exfoliative cheilitis.

    PubMed

    Bhatia, Bhavnit K; Bahr, Brooks A; Murase, Jenny E

    2015-06-01

    Exfoliative cheilitis is a condition of unknown etiology characterized by hyperkeratosis and scaling of vermilion epithelium with cyclic desquamation. It remains largely refractory to treatment, including corticosteroid therapy, antibiotics, antifungals, and immunosuppressants. We sought to evaluate the safety and efficacy of excimer laser therapy and narrowband ultraviolet B therapy in female patients with refractory exfoliative cheilitis. We reviewed the medical records of two female patients who had been treated unsuccessfully for exfoliative cheilitis. We implemented excimer laser therapy, followed by hand-held narrowband UVB treatments for maintenance therapy, and followed them for clinical improvement and adverse effects. Both patients experienced significant clinical improvement with minimal adverse effects with excimer laser therapy 600-700 mJ/cm 2 twice weekly for several months. The most common adverse effects were bleeding and burning, which occurred at higher doses. The hand-held narrowband UVB unit was also an effective maintenance tool. Limitations include small sample size and lack of standardization of starting dose and dose increments. Excimer laser therapy is a well-tolerated and effective treatment for refractory exfoliative cheilitis with twice weekly laser treatments of up to 700 mJ/cm 2 . Transitioning to the hand-held narrowband UVB device was also an effective maintenance strategy.

  2. FEL for the polymer processing industries

    NASA Astrophysics Data System (ADS)

    Kelley, Michael J.

    1997-05-01

    Polymers are everywhere in modern life because of their unique combination of end-use functionalities, ease of processing, recycling potential and modest cost. The physical and economic scope of the infrastructure committed to present polymers makes the introduction of entirely new chemistry unlikely. Rather, the breadth of commercial offerings more likely to shrink in the face of the widening mandate for recycling, especially of packaging. Improved performance and new functionality must therefore come by routes such as surface modification. However they must come with little environmental impact and at painfully low cost. Processing with strongly absorbed light offers unique advantages. The journal and patent literatures disclose a number of examples of benefits that can be achieved, principally by use of excimer lasers or special UV lamps. Examples of commercialization are few, however, because of the unit cost and maximum scale of existing light sources. A FEL, however, offers unique advantages: tunability to the optimum wavelength, potential for scale up to high average power, and a path to attractively low unit cost of light. A business analysis of prospective applications defines the technical and economic requirements a FEL for polymer surface processing must meet. These are compared to FEL technology as it now stands and as it is envisioned.

  3. Advanced Raman water vapor lidar

    NASA Technical Reports Server (NTRS)

    Whiteman, David N.; Melfi, S. Harvey; Ferrare, Richard A.; Evans, Keith A.; Ramos-Izquierdo, Luis; Staley, O. Glenn; Disilvestre, Raymond W.; Gorin, Inna; Kirks, Kenneth R.; Mamakos, William A.

    1992-01-01

    Water vapor and aerosols are important atmospheric constituents. Knowledge of the structure of water vapor is important in understanding convective development, atmospheric stability, the interaction of the atmosphere with the surface, and energy feedback mechanisms and how they relate to global warming calculations. The Raman Lidar group at the NASA Goddard Space Flight Center (GSFC) developed an advanced Raman Lidar for use in measuring water vapor and aerosols in the earth's atmosphere. Drawing on the experience gained through the development and use of our previous Nd:YAG based system, we have developed a completely new lidar system which uses a XeF excimer laser and a large scanning mirror. The additional power of the excimer and the considerably improved optical throughput of the system have resulted in approximately a factor of 25 improvement in system performance for nighttime measurements. Every component of the current system has new design concepts incorporated. The lidar system consists of two mobile trailers; the first (13m x 2.4m) houses the lidar instrument, the other (9.75m x 2.4m) is for system control, realtime data display, and analysis. The laser transmitter is a Lambda Physik LPX 240 iCC operating at 400 Hz with a XeF gas mixture (351 nm). The telescope is a .75m horizontally mounted Dall-Kirkham system which is bore sited with a .8m x 1.1m elliptical flat which has a full 180 degree scan capability - horizon to horizon within a plane perpendicular to the long axis of the trailer. The telescope and scan mirror assembly are mounted on a 3.65m x .9m optical table which deploys out the rear of the trailer through the use of a motor driven slide rail system. The Raman returns from water vapor (403 nm), nitrogen (383 nm) and oxygen (372 nm) are measured in addition to the direct Rayleigh/Mie backscatter (351). The signal from each of these is split at about a 5/95 ratio between two photomultiplier detectors. The 5 percent detector is used for measurements below about 4.0 km, while the 95 percent detector provides the information above this level.

  4. Fluorescence from polystyrene - Photochemical processes in polymeric systems, 7

    NASA Technical Reports Server (NTRS)

    Gupta, M. C.; Gupta, A.

    1983-01-01

    Results are presented for measurements of the fluorescence spectra of polystyrene in dilute solution and in pure solid films. It is determined that a major potential source of experimental error is the concurrent photooxidative degradation in air which may obscure fluorescence emission from monomeric sites in solid films at 25 C. The fluorescence spectra of oriented films are evaluated in terms of the monomer to excimer fluorescence intensity ratio and the excimer 'red shift'. The monomer to excimer fluorescence intensity ratio is determined to be significantly higher in fluid solution than in solid film.

  5. Shell-model predictions for Lambda Lambda hypernuclei

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gal, A.; Millener, D.

    2011-06-02

    It is shown how the recent shell-model determination of {Lambda}N spin-dependent interaction terms in {Lambda} hypernuclei allows for a reliable deduction of {Lambda}{Lambda} separation energies in {Lambda}{Lambda} hypernuclei across the nuclear p shell. Comparison is made with the available data, highlighting {sub {Lambda}{Lambda}}{sup 11}Be and {sub {Lambda}{Lambda}}{sup 12}Be which have been suggested as possible candidates for the KEK-E373 HIDA event.

  6. 308-nm excimer laser in endodontics

    NASA Astrophysics Data System (ADS)

    Liesenhoff, Tim

    1992-06-01

    Root canal preparation was performed on 20 extracted human teeth. After opening the coronal pulp, the root canals were prepared by 308 nm excimer laser only. All root canals were investigated under SEM after separation in the axial direction. By sagittal separation of the mandibles of freshly slaughtered cows, it was possible to get access to the tissues and irradiate under optical control. Under irradiation of excimer laser light, tissue starts to fluoresce. It was possible to demonstrate that each tissue (dentin, enamel, bone, pulpal, and connective tissue) has a characteristic spectral pattern. The SEM analyses showed that it is well possible to prepare root canals safely. All organic soft tissue has been removed by excimer laser irradiation. There was no case of via falsa. The simultaneous spectroscopic identification of the irradiated tissue provides a safe protection from overinstrumentation. First clinical trials on 20 patients suffering of chronical apical parodontitis have been carried out successfully.

  7. Laser ablation of human atherosclerotic plaque without adjacent tissue injury

    NASA Technical Reports Server (NTRS)

    Grundfest, W. S.; Litvack, F.; Forrester, J. S.; Goldenberg, T.; Swan, H. J. C.

    1985-01-01

    Seventy samples of human cadaver atherosclerotic aorta were irradiated in vitro using a 308 nm xenon chloride excimer laser. Energy per pulse, pulse duration and frequency were varied. For comparison, 60 segments were also irradiated with an argon ion and an Nd:YAG laser operated in the continuous mode. Tissue was fixed in formalin, sectioned and examined microscopically. The Nd:YAG and argon ion-irradiated tissue exhibited a central crater with irregular edges and concentric zones of thermal and blast injury. In contrast, the excimer laser-irradiated tissue had narrow deep incisions with minimal or no thermal injury. These preliminary experiments indicate that the excimer laser vaporizes tissue in a manner different from that of the continuous wave Nd:YAG or argon ion laser. The sharp incision margins and minimal damage to adjacent normal tissue suggest that the excimer laser is more desirable for general surgical and intravascular uses than are the conventionally used medical lasers.

  8. Treatment of psoriasis and long-term maintenance using 308 nm excimer laser, clobetasol spray, and calcitriol ointment: a case series.

    PubMed

    Wong, Jillian W; Nguyen, Tien V; Bhutani, Tina; Koo, John Y M

    2012-08-01

    Psoriasis is a chronic inflammatory skin disease that is characterized by thickened red plaques covered with silvery scales. Excimer laser therapy is a cutting-edge advancement in UVB phototherapy. In contrast to traditional phototherapy, the 308 nm excimer laser only targets psoriasis plaques, while it spares uninvolved skin. It allows for treatment with a supra-erythmogenic dose of UVB irradiation. Targeted UVB therapy is a possible treatment especially for many who have failed topical treatments, systemic therapy, and traditional phototherapy. For safe and effective psoriasis treatment, a combination of therapies may be used, including a combination of laser treatment with topical medications. We present two cases demonstrating effective treatment with excimer laser in conjunction with clobetasol spray and calcitriol ointment for 12 weeks. Long-term near-clearance of psoriasis was sustained after 6 months and one-year follow up periods without further therapy.

  9. Excimer laser annealing: A gold process for CZ silicon junction formation

    NASA Technical Reports Server (NTRS)

    Wong, David C.; Bottenberg, William R.; Byron, Stanley; Alexander, Paul

    1987-01-01

    A cold process using an excimer laser for junction formation in silicon has been evaluated as a way to avoid problems associated with thermal diffusion. Conventional thermal diffusion can cause bulk precipitation of SiOx and SiC or fail to completely activate the dopant, leaving a degenerate layer at the surface. Experiments were conducted to determine the feasibility of fabricating high quality p-n junctions using a pulsed excimer laser for junction formation at remelt temperature with ion-implanted surfaces. Solar-cell efficiency exceeding 16 percent was obtained using Czochralski single-crystal silicon without benefit of back surface field or surface passivation. Characterization shows that the formation of uniform, shallow junctions (approximately 0.25 micron) by excimer laser scanning preserves the minority carrier lifetime that leads to high current collection. However, the process is sensitive to initial surface conditions and handling parameters that drive the cost up.

  10. Halos--a problem for all myopes? A comparison between spectacles, contact lenses, and photorefractive keratectomy.

    PubMed

    Lohmann, C P; Fitzke, F W; O'Brart, D; Muir, M K; Marshall, J

    1993-01-01

    After photorefractive keratectomy (PRK) using excimer lasers (193 nm) many patients report the presence of halos around light sources at night. However, halos are not unique to PRK patients, as they are a common observation in myopic contact lens wearers. We present an objective measurement of the halos using a computerized technique. The patient fixated on a red cross within a white circle in the center of a video monitor which served as the halo source. The screen surrounding the circle was not illuminated. The operator controlled the movement of the white spot and moved the spot toward the halo source until the subject indicated when the cursor was at the outer parameter of the halo. Measurements were made at 30 degree intervals around the halo source and expressed as square degrees. The study found that spectacles, soft contact lenses, and excimer laser surgery were superior to hard contact lenses in terms of the size of the halo. A mean value of 2.51 square degrees was obtained for spectacles wearers compared with 3.18 square degrees for soft contact lenses, 3.14 square degrees for excimer laser patients with 4-millimeter ablation zone, 2.76 square degrees for excimer laser patients with a 5-millimeter ablation zone, and 89.5 square degrees for hard contact lenses. It appears that this device is very useful for measuring the halo size after excimer laser PRK. We concluded that halos were not a problem for our patients after excimer laser photorefractive keratectomy.

  11. Measurement of the forward-backward asymmetry of $$\\Lambda$$ and $$\\bar{\\Lambda}$$ production in $$p \\bar{p}$$ collisions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abazov, Victor Mukhamedovich

    Here, we studymore » $$\\Lambda$$ and $$\\bar{\\Lambda}$$ production asymmetries in $$p \\bar{p} \\rightarrow \\Lambda (\\bar{\\Lambda}) X$$, $$p \\bar{p} \\rightarrow J/\\psi \\Lambda (\\bar{\\Lambda}) X$$, and $$p \\bar{p} \\rightarrow \\mu^\\pm \\Lambda (\\bar{\\Lambda}) X$$ events recorded by the D0 detector at the Fermilab Tevatron collider at $$\\sqrt{s} = 1.96$$ TeV. We find an excess of $$\\Lambda$$'s ($$\\bar{\\Lambda}$$'s) produced in the proton (antiproton) direction. This forward-backward asymmetry is measured as a function of rapidity. We confirm that the $$\\bar{\\Lambda}/\\Lambda$$ production ratio, measured by several experiments with various targets and a wide range of energies, is a universal function of "rapidity loss", i.e., the rapidity difference of the beam proton and the lambda.« less

  12. Measurement of the forward-backward asymmetry of $$\\Lambda$$ and $$\\bar{\\Lambda}$$ production in $$p \\bar{p}$$ collisions

    DOE PAGES

    Abazov, Victor Mukhamedovich

    2016-02-09

    Here, we studymore » $$\\Lambda$$ and $$\\bar{\\Lambda}$$ production asymmetries in $$p \\bar{p} \\rightarrow \\Lambda (\\bar{\\Lambda}) X$$, $$p \\bar{p} \\rightarrow J/\\psi \\Lambda (\\bar{\\Lambda}) X$$, and $$p \\bar{p} \\rightarrow \\mu^\\pm \\Lambda (\\bar{\\Lambda}) X$$ events recorded by the D0 detector at the Fermilab Tevatron collider at $$\\sqrt{s} = 1.96$$ TeV. We find an excess of $$\\Lambda$$'s ($$\\bar{\\Lambda}$$'s) produced in the proton (antiproton) direction. This forward-backward asymmetry is measured as a function of rapidity. We confirm that the $$\\bar{\\Lambda}/\\Lambda$$ production ratio, measured by several experiments with various targets and a wide range of energies, is a universal function of "rapidity loss", i.e., the rapidity difference of the beam proton and the lambda.« less

  13. Excimer Lasers In Medicine

    NASA Astrophysics Data System (ADS)

    Tittel, Frank K.; Saidi, Iyad S.; Pettit, George H.; Wisoff, P. J.; Sauerbrey, Roland A.

    1989-06-01

    Excimer lasers emit light energy, short optical pulses at ultraviolet wavelengths, that results in a unique laser tissue interaction. This has led to an increasing number of studies into medical applications of these lasers in fields such as ophthalmology, urology, cardiology and neurology.

  14. Excimer Formation Dynamics of Dipyrenyldecane in Structurally Different Ionic Liquids.

    PubMed

    Yadav, Anita; Pandey, Siddharth

    2017-12-07

    Ionic liquids, being composed of ions alone, may offer alternative pathways for molecular aggregation. These pathways could be controlled by the chemical structure of the cation and the anion of the ionic liquids. Intramolecular excimer formation dynamics of a bifluorophoric probe, 1,3-bis(1-pyrenyl)decane [1Py(10)1Py], where the fluorophoric pyrene moieties are separated by a long decyl chain, is investigated in seven different ionic liquids in 10-90 °C temperature range. The long alkyl separator allows for ample interaction with the solubilizing milieu prior to the formation of the excimer. The ionic liquids are composed of two sets, one having four ionic liquids of 1-butyl-3-methylimidazolium cation ([bmim + ]) with different anions and the other having four ionic liquids of bis(trifluoromethylsulfonyl)imide anion ([Tf 2 N - ]) with different cations. The excimer-to-monomer emission intensity ratio (I E /I M ) is found to increase with increasing temperature in sigmoidal fashion. Chemical structure of the ionic liquid controls the excimer formation efficiency, as I E /I M values within ionic liquids with the same viscosities are found to be significantly different. The excited-state intensity decay kinetics of 1Py(10)1Py in ionic liquids do not adhere to a simplistic Birk's scheme, where only one excimer conformer forms after excitation. The apparent rate constants of excimer formation (k a ) in highly viscous ionic liquids are an order of magnitude lower than those reported in organic solvents. In general, the higher the viscosity of the ionic liquid, the more sensitive is the k a to the temperature with higher activation energy, E a . The trend in E a is found to be similar to that for activation energy of the viscous flow (E a,η ). Stokes-Einstein relationship is not followed in [bmim + ] ionic liquids; however, with the exception of [choline][Tf 2 N], it is found to be followed in [Tf 2 N - ] ionic liquids suggesting the cyclization dynamics of 1Py(10)1Py to be diffusion-controlled and to depend on the viscosity of the ionic liquid irrespective of the identity of the cation. The dependence of ionic liquid structure on cyclization dynamics to form intramolecular excimer is amply highlighted.

  15. Endobronchial Forceps-Assisted and Excimer Laser-Assisted Inferior Vena Cava Filter Removal: The Data, Where We Are, and How It Is Done.

    PubMed

    Chen, James X; Montgomery, Jennifer; McLennan, Gordon; Stavropoulos, S William

    2018-06-01

    The recognition of inferior vena cava filter related complications has motivated increased attentiveness in clinical follow-up of patients with inferior vena cava filters and has led to development of multiple approaches for retrieving filters that are challenging or impossible to remove using conventional techniques. Endobronchial forceps and excimer lasers are tools for designed to aid in complex inferior vena cava filter removals. This article discusses endobronchial forceps-assisted and excimer laser-assisted inferior vena cava filter retrievals. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Bragg reflector based gate stack architecture for process integration of excimer laser annealing

    NASA Astrophysics Data System (ADS)

    Fortunato, G.; Mariucci, L.; Cuscunà, M.; Privitera, V.; La Magna, A.; Spinella, C.; Magrı, A.; Camalleri, M.; Salinas, D.; Simon, F.; Svensson, B.; Monakhov, E.

    2006-12-01

    An advanced gate stack structure, which incorporates a Bragg reflector, has been developed for the integration of excimer laser annealing into the power metal-oxide semiconductor (MOS) transistor fabrication process. This advanced gate structure effectively protects the gate stack from melting, thus solving the problem related to protrusion formation. By using this gate stack configuration, power MOS transistors were fabricated with improved electrical characteristics. The Bragg reflector based gate stack architecture can be applied to other device structures, such as scaled MOS transistors, thus extending the possibilities of process integration of excimer laser annealing.

  17. Three hundred and eight nanometer excimer light therapy for alopecia universalis that is resistant to other treatments: A clinical study of 11 patients.

    PubMed

    Arakawa, Yukiyasu; Nomiyama, Tomoko; Katoh, Norito

    2016-12-01

    Three hundred and eight nanometer excimer light therapy has recently been reported to be effective against patchy alopecia areata (AA) in several clinical studies. However, these studies only included a few patients with severe forms of AA, and all of them exhibited poor outcomes. We further investigated the use of excimer light as a therapeutic option for cases of alopecia universalis (AU) that are resistant to other treatments. Eleven treatment-resistant AU patients were treated with a 308-nm excimer light at 2-week intervals for more than 16 sessions. Four patients achieved good responses and two patients exhibited poor responses. Three patients had Japanese skin type 1 and all of them achieved good responses. The radiation dose was increased until the patients exhibited marked erythema. The patients with Japanese skin type 3 who achieved good responses exhibited strong pigmentation at the irradiated sites. In conclusion, 308-nm excimer light therapy has significant effects on some AU patients who are resistant to other treatments and may be an alternative therapeutic option for AU. During the treatment of AU, high doses of radiation should be administrated until a strong inflammatory skin reaction is seen. © 2016 Japanese Dermatological Association.

  18. Advances in 193 nm excimer lasers for mass spectrometry applications

    NASA Astrophysics Data System (ADS)

    Delmdahl, Ralph; Esser, Hans-Gerd; Bonati, Guido

    2016-03-01

    Ongoing progress in mass analysis applications such as laser ablation inductively coupled mass spectrometry of solid samples and ultraviolet photoionization mediated sequencing of peptides and proteins is to a large extent driven by ultrashort wavelength excimer lasers at 193 nm. This paper will introduce the latest improvements achieved in the development of compact high repetition rate excimer lasers and elaborate on the impact on mass spectrometry instrumentation. Various performance and lifetime measurements obtained in a long-term endurance test over the course of 18 months will be shown and discussed in view of the laser source requirements of different mass spectrometry tasks. These sampling type applications are served by excimer lasers delivering pulsed 193 nm output of several mJ as well as fast repetition rates which are already approaching one Kilohertz. In order to open up the pathway from the laboratory to broader market industrial use, sufficient component lifetimes and long-term stable performance behavior have to be ensured. The obtained long-term results which will be presented are based on diverse 193 nm excimer laser tube improvements aiming at e.g. optimizing the gas flow dynamics and have extended the operational life the laser tube for the first time over several billion pulses even under high duty-cycle conditions.

  19. Excimer-laser-induced surface treatments on metal and ceramic materials: applications to automotive, aerospace, and microelectronic industries

    NASA Astrophysics Data System (ADS)

    Autric, Michel L.

    1999-09-01

    Surface treatments by laser irradiation can improve materials properties in terms of mechanical and physico- chemical behaviors, these improvements being related to the topography, the hardness, the microstructure, the chemical composition. Up to now, the use of excimer lasers for industrial applications remained marginal in spite of the interest related to the short wavelength (high photon energy and better energetic coupling with materials and reduced thermal effects in the bulk material). Up to now, the main limitations concerned the beam quality, the beam delivery, the gas handling and the relatively high investment cost. At this time, the cost of laser devices is going down and the ultraviolet radiation can be conducted through optical fibers. These two elements give new interest in using excimer laser for industrial applications. The main objective of this research program which we are involved in, is to underline some materials processing applications for automotive, aerospace or microelectronic industries for which it could be more interesting to use excimer lasers (minimized thermal effects). This paper concerns the modifications of the roughness, porosity, hardness, structure, phase, residual stresses, chemical composition of the surface of materials such as metallic alloys (aluminum, steel, cast iron, titanium, and ceramics (oxide, nitride, carbide,...) irradiated by KrF and XeCl excimer lasers.

  20. Excimer laser coronary angioplasty: relative risk analysis of clinical results

    NASA Astrophysics Data System (ADS)

    Bittl, John A.

    1992-08-01

    Reports of successful use of excimer laser coronary angioplasty for complex coronary artery disease abound, yet firm indications for its use have not been defined. We attempted to treat 858 coronary stenoses in 764 consecutive patients (mean age 61 years; range 32 - 91 years; 75% men; 76% with Class III or IV angina) with excimer laser angioplasty at 308 nm. Successful treatment was achieved in 86% of patients, as indicated by 20 mm), total occlusions and calcified lesions were treated as successfully as all other lesion types. Successful treatment with excimer laser coronary angioplasty was also achieved in almost all patients (15/16) who had a prior unsuccessful attempt at balloon angioplasty in the lesion was crossed with a guidewire yet resists either balloon catheter passage or full dilatation. Follow-up angiography was obtained in 70% of eligible patients. Angiographic restenosis, defined by > 50% stenosis, was seen in 60% of patients. Relative risk analysis showed an increased risk of restenosis when adjunctive balloon angioplasty was not used (OR equals 1.68; 95% CI equals 1.02, 2.28; P equals 0.039). Other variables known to affect the outcome of balloon angioplasty, such as lesion length or stenosis in degenerated saphenous vein bypass graft, did not influence the restenosis rates. This analysis defines the profile of risk for excimer laser angioplasty and now provides a sound basis for future, rigorous comparison of excimer laser and balloon angioplasty to balloon angioplasty for a group of lesions that appear to have acceptable success rates with excimer laser coronary angioplasty, which we have denoted the `alpha class' -- saphenous vein lesions, long lesions, ostial stenoses, lesions in calcified vessels, total occlusions, and balloon dilatation failures. Although adjunctive balloon angioplasty may be beneficial, restenosis remains a significant limitation of the procedure and will restrict the usefulness of excimer laser coronary angioplasty for may other types of lesions.

  1. Measurements of J/{psi} and {psi}(2S) decays into {lambda}{lambda}{pi}{sup 0} and {lambda}{lambda}{eta}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ablikim, M.; Bai, J. Z.; Cai, X.

    2007-11-01

    Using 58x10{sup 6} J/{psi} and 14x10{sup 6} {psi}(2S) events collected by the BESII detector at the BEPC, branching fractions or upper limits for the decays J/{psi} and {psi}(2S){yields}{lambda}{lambda}{pi}{sup 0} and {lambda}{lambda}{eta} are measured. For the isospin violating decays, the upper limits are determined to be B(J/{psi}{yields}{lambda}{lambda}{pi}{sup 0})<6.4x10{sup -5} and B[{psi}(2S){yields}{lambda}{lambda}{pi}{sup 0}]<4.9x10{sup -5} at the 90% confidence level. The isospin conserving process J/{psi}{yields}{lambda}{lambda}{eta} is observed for the first time, and its branching fraction is measured to be B(J/{psi}{yields}{lambda}{lambda}{eta})=(2.62{+-}0.60{+-}0.44)x10{sup -4}, where the first error is statistical and the second one is systematic. No {lambda}{lambda}{eta} signal is observed in {psi}(2S) decays, and B[{psi}(2S){yields}{lambda}{lambda}{eta}]<1.2x10{supmore » -4} is set at the 90% confidence level. Branching fractions of J/{psi} decays into {sigma}{sup +}{pi}{sup -}{lambda} and {sigma}{sup -}{pi}{sup +}{lambda} are also reported, and the sum of these branching fractions is determined to be B(J/{psi}{yields}{sigma}{sup +}{pi}{sup -}{lambda}+c.c.)=(1.52{+-}0.08{+-}0.16)x10{sup -3}.« less

  2. Measurement of the branching fraction $${\\mathcal{B}}(\\Lambda^0_b\\rightarrow \\Lambda^+_c\\pi^-\\pi^+\\pi^-)$$ at CDF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aaltonen, T.; /Helsinki Inst. of Phys.; Alvarez Gonzalez, B.

    We report an analysis of the {Lambda}{sub b}{sup 0} {yields} {Lambda}{sub c}{sup +}{pi}{sup -}{pi}{sup +}{pi}{sup -} decay in a data sample collected by the CDF II detector at the Fermilab Tevatron corresponding to 2.4 fb{sup -1} of integrated luminosity. We reconstruct the currently largest samples of the decay modes {Lambda}{sub b}{sup 0} {yields} {Lambda}{sub c}(2595){sup +}{pi}{sup -} (with {Lambda}{sub c}(2595){sup +} {yields} {Lambda}{sub c}{sup +}{pi}{sup +}{pi}{sup -}), {Lambda}{sub b}{sup 0} {yields} {Lambda}{sub c}(2625){sup +}{pi}{sup -} (with {Lambda}{sub c}(2625){sup +} {yields} {Lambda}{sub c}{sup +}{pi}{sup +}{pi}{sup -}), {Lambda}{sub b}{sup 0} {yields} {Sigma}{sub c}(2455){sup ++}{pi}{sup -}{pi}{sup -} (with {Sigma}{sub c}(2455){sup ++} {yields} {Lambda}{submore » c}{sup +}{pi}{sup +}), and {Lambda}{sub b}{sup 0} {yields} {Sigma}{sub c}(2455)0{pi}{sup +}{pi}{sup -} (with {Sigma}{sub c}(2455)0 {yields} {Lambda}{sub c}{sup +}{pi}{sup -}) and measure the branching fractions relative to the {Lambda}{sub b}{sup 0} {yields} {Lambda}{sub c}{sup +}{pi}{sup -} branching fraction. We measure the ratio {Beta}({Lambda}{sub b}{sup 0} {yields} {Lambda}{sub c}{sup +}{pi}{sup -}{pi}{sup +}{pi}{sup -})/ {Beta}({Lambda}{sub b}{sup 0} {yields} {Lambda}{sub c}{sup +}{pi}{sup -})=3.04 {+-} 0.33(stat){sub -0.55}{sup +0.70}(syst) which is used to derive {Beta}({Lambda}{sub b}{sup 0} {yields} {Lambda}{sub c}{sup +}{pi}{sup -}{pi}{sup +}{pi}{sup -})=(26.8{sub -11.2}{sup +11.9}) x 10{sup -3}.« less

  3. Study of B{yields}{lambda}{sub c}{lambda}{sub c} and B{yields}{lambda}{sub c}{lambda}{sub c}K

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, H.-Y.; Hsiao, Y.-K.; Chua, C.-K.

    2009-06-01

    We study the doubly charmful two-body and three-body baryonic B decays B{yields}{lambda}{sub c}{sup +}{lambda}{sub c}{sup -} and B{yields}{lambda}{sub c}{sup +}{lambda}{sub c}{sup -}K. As pointed out before, a naive estimate of the branching ratio O(10{sup -8}) for the latter decay is too small by 3 to 4 orders of magnitude compared to experiment. Previously, it has been shown that a large enhancement for the {lambda}{sub c}{sup +}{lambda}{sub c}{sup -}K production can occur due to a charmoniumlike resonance (e.g. X(4630) discovered by Belle) with a mass near the {lambda}{sub c}{lambda}{sub c} threshold. Motivated by the BABAR's observation of a resonance in themore » {lambda}{sub c}K system with a mass of order 2930 MeV, we study in this work the contribution to B{yields}{lambda}{sub c}{sup +}{lambda}{sub c}{sup -}K from the intermediate state {xi}{sub c}(2980) which is postulated to be a first positive-parity excited D-wave charmed baryon state. Assuming that a soft qq quark pair is produced through the {sigma} and {pi} meson exchanges in the configuration for B{yields}{xi}{sub c}(2980){lambda}{sub c} and {lambda}{sub c}{lambda}{sub c}, it is found that branching ratios of B{yields}{lambda}{sub c}{sup +}{lambda}{sub c}{sup -}K and B{yields}{lambda}{sub c}{sup +}{lambda}{sub c}{sup -} are of order 3.5x10{sup -4} and 5x10{sup -5}, respectively, in agreement with experiment except that the prediction for the {lambda}{sub c}{lambda}{sub c}K{sup -} is slightly smaller. In conjunction with our previous analysis, we conclude that the enormously large rate of B{yields}{lambda}{sub c}{sup +}{lambda}{sub c}{sup -}K arises from the resonances {xi}{sub c}(2980) and X(4630)« less

  4. Measurement of the $$\\Lambda_b$$ cross section and the $$_{\\bar{\\Lambda}_b}$$ to $$\\Lambda_b$$ ratio with $$J/\\Psi \\Lambda$$ decays in $pp$ collisions at $$\\sqrt{s}=7$$ TeV

    DOE PAGES

    Chatrchyan, Serguei; et al.

    2013-07-16

    The Lambda(b) differential production cross section and the cross section ratio anti-Lambda(b)/Lambda(b) are measured as functions of transverse momentum pt(Lambda(b)) and rapidity abs(y(Lambda(b))) in pp collisions at sqrt(s) = 7 TeV using data collected by the CMS experiment at the LHC. The measurements are based on Lambda(b) decays reconstructed in the exclusive final state J/Psi Lambda, with the subsequent decays J/Psi to an opposite-sign muon pair and Lambda to proton pion, using a data sample corresponding to an integrated luminosity of 1.9 inverse femtobarns. The product of the cross section times the branching ratio for Lambda(b) to J/Psi Lambda versusmore » pt(Lambda(b)) falls faster than that of b mesons. The measured value of the cross section times the branching ratio for pt(Lambda(b)) > 10 GeV and abs(y(Lambda(b))) < 2.0 is 1.06 +/- 0.06 +/- 0.12 nb, and the integrated cross section ratio for anti-Lambda(b)/Lambda(b) is 1.02 +/- 0.07 +/- 0.09, where the uncertainties are statistical and systematic, respectively.« less

  5. Distinctive Spectral Features of Exciton and Excimer States in the Ultrafast Electronic Deactivation of the Adenine Dinucleotide

    NASA Astrophysics Data System (ADS)

    Stuhldreier, Mayra C.; Röttger, Katharina; Temps, Friedrich

    We report the observation by transient absorption spectroscopy of distinctive spectro-temporal signatures of delocalized exciton versus relaxed, weakly bound excimer states in the ultrafast electronic deactivation after UV photoexcitation of the adenine dinucleotide.

  6. Forming n/p Junctions With An Excimer Laser

    NASA Technical Reports Server (NTRS)

    Alexander, Paul, Jr.; Campbell, Robert B.; Wong, David C.; Bottenberg, William L.; Byron, Stanley

    1988-01-01

    Compact equipment yields high-quality solar cells. Computer controls pulses of excimer laser and movement of silcon wafer. Mirrors direct laser beam to wafer. Lenses focus beam to small spot on surface. Process suitable for silicon made by dendritic-web-growth process.

  7. A study of the influence of Hg(6(3)P2) population in a low-pressure discharge on mercury ion emission at 194.2 nm

    NASA Technical Reports Server (NTRS)

    Maleki, L.; Blasenheim, B. J.; Janik, G. R.

    1990-01-01

    A low-pressure mercury-argon discharge, similar to the type existing in the mercury lamp for the trapped-ion standard, is probed with a new technique of laser spectroscopy to determine the influence of the Hg(6 3P(sub 2)) population on discharge emission. The discharge is excited with inductively coupled rf power. Variations in the intensity of emission lines in the discharge were examined as lambda = 546.1 nm light from a continuous wave (CW) laser excited the Hg(6 3P(sub 2)) to (7 3S (sub 1)) transition. The spectrum of the discharge viewed in the region of laser irradiation showed increased emission in lambda = 546.1, 435.8, 404.7, 253.7, and 194.2 nm lines. Other lines in Hg I exhibited a decrease in emission. When the discharge was viewed outside the region of laser irradiation, all lines exhibited an increased emission. Based on these results, it is concluded that the dominant mechanism for the excitation of higher lying levels of mercury is the the electron-impact excitation via the 3P(sub 2) level. The depopulation of this metastable is also responsible for the observed increase in the electron temperature when the laser irradiates the discharge. It is also concluded that the 3P(sub 2) metastable level of mercury does not play a significant role in the excitation of the 3P(sub 1/2) level of mercury ion.

  8. The nature of unusual luminescence in natural calcite, CaCO3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaft, M.; Nagli, L.; Panczer, G.

    2008-11-01

    The unusual luminescence of particular varieties of natural pink calcite (CaCO{sub 3}) samples was studied by laser-induced time-resolved luminescence spectroscopy at different temperatures. The luminescence is characterized by intense blue emission under short-wave UV lamp excitation with an extremely long decay time, accompanied by pink-orange luminescence under long wave UV excitation. Our investigation included optical absorption, natural thermostimulated luminescence (NTL) and Laser-Induced Breakdown Spectroscopy (LIBS) studies. Two luminescence centers were detected: a narrow violet band, with {lambda}{sub max} = 412 nm, {Delta} = 45 nm, two decay components of {tau}{sub 1} = 5 ns and {tau}{sub 2} = 7.2 ms,more » accompanied by very long afterglow, and an orange emission band with {lambda}{sub max} = 595 nm, {Delta} = 90 nm and {tau} = 5 ns. Both luminescence centers are thermally unstable with the blue emission disappearing after heating at 500 C, and the orange emission disappearing after heating at different temperatures starting from 230 C, although sometimes it is stable up to 500 C in different samples. Both centers have spectral-kinetic properties very unusual for mineral luminescence, which in combination with extremely low impurity concentrations, prevent their identification with specific impurity related emission. The most likely explanation of these observations may be the presence of radiation-induced luminescence centers. The long violet afterglow is evidently connected with trapped charge carrier liberation, with their subsequent migration through the valence band and ultimate recombination with a radiation-induced center responsible for the unusual violet luminescence.« less

  9. Treatment of oral lichen planus using 308-nm excimer laser.

    PubMed

    Liu, Wei-Bing; Sun, Li-Wei; Yang, Hua; Wang, Yan-Fei

    2017-09-01

    Oral lichen planus (OLP) is a chronic inflammatory disease, has prolonged courses, repeated attacks and resistance to treatment. The traditional narrow spectrum UVB treatment has an established efficacy on skin lichen planus, and high safety. However, most of ultraviolet phototherapy devices have a huge volume, thereby cannot be used in the treatment of OLP. Lymphocytic infiltration is evident in the lesions of lichen planus, and the direct irradiation of 308-nm excimer laser can induce apoptosis of the T lymphocytes in skin lesions, thereby has a unique therapeutic effect on the diseases involving T lymphocytes. This study aims to investigate the efficacy of 308-nm excimer laser in the treatment of OLP. A total of six OLP patients were enrolled into this study, and further pathological diagnosis was conducted, then 308-nm excimer laser was used in the treatment. The efficacy of 308-nm excimer laser in the treatment of OLP was satisfactory. The clinical symptoms of five patients were significantly improved. In two patients, the erosion surface based on congestion and the surrounding white spots completely disappeared, and clinical recovery was achieved. Three patients achieved partial remission, that is, the erosion surface healed, congestion and white spot area shrunk by more than 1/2 of the primary skin lesions. In the remaining one patient, the erosion surface had not completely healed after treatment, and congestion and white spot area shrunk by less than 1/2 of the primary skin lesions. Only one patients had developed mild pain during the treatment, and this symptom alleviated by itself. The 308-nm excimer laser therapy can serve as a safe and effective treatment for OLP. © 2017 Wiley Periodicals, Inc.

  10. Improving the ablation efficiency of excimer laser systems with higher repetition rates through enhanced debris removal and optimized spot pattern.

    PubMed

    Arba-Mosquera, Samuel; Klinner, Thomas

    2014-03-01

    To evaluate the reasons for the required increased radiant exposure for higher-repetition-rate excimer lasers and determine experimentally possible compensations to achieve equivalent ablation profiles maintaining the same single-pulse energies and radiant exposures for laser repetition rates ranging from 430 to 1000 Hz. Schwind eye-tech-solutions GmbH and Co. KG, Kleinostheim, Germany. Experimental study. Poly(methyl methacrylate) (PMMA) plates were photoablated. The pulse laser energy was maintained during all experiments; the effects of the flow of the debris removal, the shot pattern for the correction, and precooling the PMMA plates were evaluated in terms of achieved ablation versus repetition rate. The mean ablation performance ranged from 88% to 100%; the variability between the profile measurements ranged from 1.4% to 6.2%. Increasing the laser repetition rate from 430 Hz to 1000 Hz reduced the mean ablation performance from 98% to 91% and worsened the variability from 1.9% to 4.3%. Increasing the flow of the debris removal, precooling the PMMA plates to -18°C, and adapting the shot pattern for the thermal response of PMMA to excimer ablation helped stabilize the variability. Only adapting the shot pattern for the thermal response of PMMA to excimer ablation helped stabilize the mean ablation performance. The ablation performance of higher-repetition-rate excimer lasers on PMMA improved with improvements in the debris removal systems and shot pattern. More powerful debris removal systems and smart shot patterns in terms of thermal response improved the performance of these excimer lasers. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Formation of short high-power laser radiation pulses in excimer mediums

    NASA Astrophysics Data System (ADS)

    Losev, V. F., Sr.; Ivanov, N. G.; Panchenko, Yu. N.

    2007-06-01

    Presently an excimer mediums continue are examined as one of variants for formation of powerful and over powerful pulses of laser radiation with duration from units of nanosecond up to tens femtosecond. The researches on such powerful installations as "NIKE" (USA) and << SUPER ASHURA >>, Japan) proceed in this direction. The main advantage of excimer mediums is the opportunity to work in a frequency mode, absence of restriction on the size of active area, high uniformity of a gas working medium, high efficiency (up to 10 %) and wide spectral range of laser radiation (KrF, XeCl ~ 2nm, XeF (C-A), Xe IICl ~ 50-100 nanometers). Research in area of high quality laser beams formation in excimer mediums and its amplification in high power amplifiers are carried out the long time in Institute of High Current Electronics SB RAS, Tomsk, Russia. The wide aperture XeCl laser system of MELS-4k is used for these investigations. Last time we take part in program on development of high power excimer laser system with a petawatt level of power. This system supposes the formation and amplification high quality laser beams with different pulse duration from units of nanosecond up to tens femtosecond. We research the possibility of laser beams formation in excimer mediums with ps-ns pulse duration having the low noise and divergence near to diffraction limit. In other hand, we are developing the wide aperture XeF(C-A) amplifier with optical pump on base electron accelerator. According to our estimations of the XeF(C-A) amplifier based on the converter of e-beam energy to the Xe II* fluorescence at 172 nm will allow to obtain up to 100 TW peak power in a 30 fs pulse.

  12. [The expression of interferon-lambda1 in CHO cell].

    PubMed

    Yuan, Wu-Mei; Ma, Fen-Lian; Zhang, Qian; Zheng, Wen-Zhi; Zheng, Li-Shu

    2013-06-01

    To construct the eukaryotic expression vector PCI-dhfr-lambda1 and PCI-dhfr-SP163-lambda1 which linked the enhancer SP163 with interferon lambda1. Then express the interferon lambda1 in CHO (dhfr-) cells. Using PCR method to introduce the restriction enzyme sites and through the fusion PCR binding the enhancer with the interferon Lambda1. After sequenced, lambda1 and SP163-lambda1 was inserted into PCI-dhfr forming the expression vector PCI-dhfr-lambda1 and PCI-dhfr-SP163-lambda1 which was constructed successfully confirming by sequencing. Then the expressing vectors were transfected into CHO (dhfr-) cells using liposome transfection method and interferon lambda1 protein was assayed with indirect immunofluorescence and Western Blot. Using cytopathic effect inhibition evaluated the antiviral activity of interferon lambda1. Successfully constructing the eukaryotic expression vectors of interferon lambda and the vectors could express interferon lambda1. The result of immunofluorescence showed the enhancer developed the expression of interferon lambda1. Detecting the interferon lambda1 in CHO (dhfr-) cells after transfecting 48 hour using Western Blot. The cytopathic effect inhibition showed the expressed interferon lambda1 has the antiviral activity. Successfully expressed the interferon lambda1 in CHO (dhfr-) cells and the protein possesses antiviral activity, which may supply a valuable basis for building the stable cell line of interferon lambda1.

  13. Energy of the ground and 2{sup +} excited states of {sub {lambda}}{sub {lambda}}{sup 10}Be: A partial ten-body model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shoeb, Mohammad; Sonika

    2009-08-15

    The energies of the ground and excited 2{sup +} states of {sub {lambda}}{sub {lambda}}{sup 10}Be have been calculated variationally in the Monte Carlo framework. The hypernucleus is treated as a partial ten-body problem in the {lambda}{lambda}+{alpha}{alpha} model where nucleonic degrees of freedom of {alpha}'s are taken into consideration ignoring the antisymmetrization between two {alpha}'s. The central two-body {lambda}N and {lambda}{lambda} and the three-body dispersive and two-pion exchange {lambda}NN forces, constrained by the {lambda}p scattering data and the observed ground state energies of {sub {lambda}}{sup 5}He and {sub {lambda}}{sub {lambda}}{sup 6}He, are employed. The product-type trial wave function predicts binding energymore » for the ground state considerably less than for the event reported by Danysz et al.; however, it is consistent with the value deduced assuming a {gamma} ray of 3.04 MeV must have escaped undetected in the decay of the product {sub {lambda}}{sup 9}Be* {yields} {sub {lambda}}{sup 9}Be+{gamma} of the emulsion event {sub {lambda}}{sub {lambda}}{sup 10}Be{yields} {pi}{sup -}+p+{sub {lambda}}{sup 9}Be* and for the excited 2{sup +} state closer to the value measured in the Demachi-Yanagi event. The hypernucleus {sub {lambda}}{sub {lambda}}{sup 10}Be has an oblate shape in the excited state. These results are consistent with the earlier four-body {alpha} cluster model approach where {alpha}'s are assumed to be structureless entities.« less

  14. Characterization of absorption and degradation on optical components for high power excimer lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mann, K.; Eva, E.; Granitza, B.

    1996-12-31

    At Laser-Laboratorium Goettingen, the performance of UV optical components for high power excimer lasers is characterized, aiming to employ testing procedures that meet industrial conditions, i.e. very high pulse numbers and repetition rates. Measurements include determination of single and multiple pulse damage thresholds, absorption loss and degradation of optical properties under long-term irradiation. Absorption of excimer laser pulses is investigated by a calorimetric technique which provides greatly enhanced sensitivity compared to transmissive measurements. Thus, it allows determining both single and two photon absorption coefficients at intensities of standard excimer lasers. Results of absorption measurements at 248nm are presented for baremore » substrates (CaF{sub 2}, BaF{sub 2}, z-cut quartz and fused silica). UV calorimetry is also employed to investigate laser induced aging phenomena, e.g. color center formation in fused silica. A separation of transient and cumulative effects as a function of intensity is achieved, giving insight into various loss mechanisms.« less

  15. Myopic keratomileusis by excimer laser on a lathe.

    PubMed

    Ganem, S; Aron-Rosa, D; Gross, M; Rosolen, S

    1994-01-01

    We designed an excimer laser keratomileusis delivery system to increase the regularity of the refractive cut surface and allow greater precision in the level and shape of the ablated zone. A parallel faced corneal disc was produced by microkeratectomy from six human eyes and surgical keratectomy in 12 beagle corneas. A 193-nanometer excimer laser that was used to project an oval beam onto the corneal disc was rotated on a flat surface to ensure overlapping of the ovally ablated areas between pulses. Electron microscopy of eye bank lenticules demonstrated a circular smooth regularly concave ablation zone. Histological examination of nine clear corneas confirmed thinning of the stroma without fibroblastic reaction and no epithelial hypertrophy. Mean preoperative corneal power of 43.15 +/- 2.18 decreased postoperatively to 33.61 +/- 2.34. The new technique of excimer laser keratomileusis has the advantage of a cut surface smoother and the clear zone is devoid of the stepwise concavity and irregularity seen in diaphragm based photoablation delivery systems.

  16. Evaluation of corneal ablation by an optical parametric oscillator (OPO) at 2.94 μm and an Er:YAG laser and comparison to ablation by a 193-nm excimer laser

    NASA Astrophysics Data System (ADS)

    Telfair, William B.; Hoffman, Hanna J.; Nordquist, Robert E.; Eiferman, Richard A.

    1998-06-01

    Purpose: This study first evaluated the corneal ablation characteristics of (1) an Nd:YAG pumped OPO (Optical Parametric Oscillator) at 2.94 microns and (2) a short pulse Er:YAG laser. Secondly, it compared the histopathology and surface quality of these ablations with (3) a 193 nm excimer laser. Finally, the healing characteristics over 4 months of cat eyes treated with the OPO were evaluated. Methods: Custom designed Nd:YAG/OPO and Er:YAG lasers were integrated with a new scanning delivery system to perform PRK myopic correction procedures. After initial ablation studies to determine ablation thresholds and rates, human cadaver eyes and in-vivo cat eyes were treated with (1) a 6.0 mm Dia, 30 micron deep PTK ablation and (2) a 6.0 mm Dia, -5.0 Diopter PRK ablation. Cadaver eyes were also treated with a 5.0 mm Dia, -5.0 Diopter LASIK ablation. Finally, cats were treated with the OPO in a 4 month healing study. Results: Ablation thresholds below 100 mJ/cm2 and ablation rates comparable to the excimer were demonstrated for both infrared systems. Light Microscopy (LM) showed no thermal damage for low fluence treatments, but noticeable thermal damage at higher fluences. SEM and TEM revealed morphologically similar surfaces for low fluence OPO and excimer samples with a smooth base and no evidence of collagen shrinkage. The Er:YAG and higher fluence OPO treated samples revealed more damage along with visible collagen coagulation and shrinkage in some cases. Healing was remarkably unremarkable. All eyes had a mild healing response with no stromal haze and showed topographic flattening. LM demonstrated nothing except a moderate increase in keratocyte activity in the upper third of the stroma. TEM confirmed this along with irregular basement membranes. Conclusions: A non- thermal ablation process called photospallation is demonstrated for the first time using short pulse infrared lasers yielding damage zones comparable to the excimer and healing which is also comparable to the excimer. Such Infrared sources are, therefore, potentially attractive competitors to the excimer to perform PRK and LASIK.

  17. Charge versus Energy Transfer Effects in High-Performance Perylene Diimide Photovoltaic Blend Films.

    PubMed

    Singh, Ranbir; Shivanna, Ravichandran; Iosifidis, Agathaggelos; Butt, Hans-Jürgen; Floudas, George; Narayan, K S; Keivanidis, Panagiotis E

    2015-11-11

    Perylene diimide (PDI)-based organic photovoltaic devices can potentially deliver high power conversion efficiency values provided the photon energy absorbed is utilized efficiently in charge transfer (CT) reactions instead of being consumed in nonradiative energy transfer (ET) steps. Hitherto, it remains unclear whether ET or CT primarily drives the photoluminescence (PL) quenching of the PDI excimer state in PDI-based blend films. Here, we affirm the key role of the thermally assisted PDI excimer diffusion and subsequent CT reaction in the process of PDI excimer PL deactivation. For our study we perform PL quenching experiments in the model PDI-based composite made of poly[4,8-bis(5-(2-ethylhexyl)thiophen-2-yl)benzo[1,2-b;4,5-b']dithiophene-2,6-diyl-alt-(4-(2-ethylhexanoyl)-thieno[3,4-b]thiophene)-2-6-diyl] (PBDTTT-CT) polymeric donor mixed with the N,N'-bis(1-ethylpropyl)-perylene-3,4,9,10-tetracarboxylic diimide (PDI) acceptor. Despite the strong spectral overlap between the PDI excimer PL emission and UV-vis absorption of PBDTTT-CT, two main observations indicate that no significant ET component operates in the overall PL quenching: the PL intensity of the PDI excimer (i) increases with decreasing temperature and (ii) remains unaffected even in the presence of 10 wt % content of the PBDTTT-CT quencher. Temperature-dependent wide-angle X-ray scattering experiments further indicate that nonradiative resonance ET is highly improbable due to the large size of PDI domains. The dominance of the CT over the ET process is verified by the high performance of devices with an optimum composition of 30:70 PBDTTT-CT:PDI. By adding 0.4 vol % of 1,8-diiodooctane we verify the plasticization of the polymer side chains that balances the charge transport properties of the PBDTTT-CT:PDI composite and results in additional improvement in the device efficiency. The temperature-dependent spectral width of the PDI excimer PL band suggests the presence of energetic disorder in the PDI excimer excited state manifold.

  18. [The 308 nm Excimer laser for the treatment of psoriasis and inflammatory skin diseases].

    PubMed

    Fritz, K; Salavastru, C

    2018-01-01

    Overall, the 308 nm Excimer laser enables not only a more effective and safer UVB therapy than classical UV phototherapy, but also targeted irradiation in higher doses with a lower cumulative load, which results in faster healing of mainly circumscribed skin changes. This also applies to therapy-resistant residual lesions which, despite systemic therapy, did not diminish. Combination therapies usually improve the result and enable the dose of UVB and systemic medication to be reduced. Excimer laser therapy can be used for an increasing number of skin diseases, especially those that respond to phototherapy or photochemotherapy.

  19. Beauty Baryons at CDF and DO

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kryemadhi, Abaz

    The results from Tevatron in the baryonic sector are presented. The lifetime of {lambda}b {yields} J/{psi}{lambda}, the observation of hadronic decay of {lambda}b {yields} {lambda}c{pi}, the semileptonic decays of {lambda}b {yields} {lambda}c{mu}{nu}, the hadronization of the b-baryons, and the {lambda}b decays to {lambda}b {yields} p{pi} and {lambda}b {yields} pK are discussed. These measurements paint a nice picture of our understanding of the beauty baryons.

  20. Improved measurement of the form factors in the decay lambda+c-->lambda + nue.

    PubMed

    Hinson, J W; Huang, G S; Lee, J; Miller, D H; Pavlunin, V; Rangarajan, R; Sanghi, B; Shibata, E I; Shipsey, I P J; Cronin-Hennessy, D; Park, C S; Park, W; Thayer, J B; Thorndike, E H; Coan, T E; Gao, Y S; Liu, F; Stroynowski, R; Artuso, M; Boulahouache, C; Blusk, S; Dambasuren, E; Dorjkhaidav, O; Mountain, R; Muramatsu, H; Nandakumar, R; Skwarnicki, T; Stone, S; Wang, J C; Csorna, S E; Danko, I; Bonvicini, G; Cinabro, D; Dubrovin, M; McGee, S; Bornheim, A; Lipeles, E; Pappas, S P; Shapiro, A; Sun, W M; Weinstein, A J; Briere, R A; Chen, G P; Ferguson, T; Tatishvili, G; Vogel, H; Watkins, M E; Adam, N E; Alexander, J P; Berkelman, K; Boisvert, V; Cassel, D G; Duboscq, J E; Ecklund, K M; Ehrlich, R; Galik, R S; Gibbons, L; Gittelman, B; Gray, S W; Hartill, D L; Heltsley, B K; Hsu, L; Jones, C D; Kandaswamy, J; Kreinick, D L; Magerkurth, A; Mahlke-Krüger, H; Meyer, T O; Mistry, N B; Patterson, J R; Peterson, D; Pivarski, J; Richichi, S J; Riley, D; Sadoff, A J; Schwarthoff, H; Shepherd, M R; Thayer, J G; Urner, D; Wilksen, T; Warburton, A; Weinberger, M; Athar, S B; Avery, P; Breva-Newell, L; Potlia, V; Stoeck, H; Yelton, J; Benslama, K; Cawlfield, C; Eisenstein, B I; Gollin, G D; Karliner, I; Lowrey, N; Plager, C; Sedlack, C; Selen, M; Thaler, J J; Williams, J; Edwards, K W; Besson, D; Anderson, S; Frolov, V V; Gong, D T; Kubota, Y; Li, S Z; Poling, R; Smith, A; Stepaniak, C J; Urheim, J; Metreveli, Z; Seth, K K; Tomaradze, A; Zweber, P; Ahmed, S; Alam, M S; Ernst, J; Jian, L; Saleem, M; Wappler, F; Arms, K; Eckhart, E; Gan, K K; Gwon, C; Honscheid, K; Kagan, H; Kass, R; Pedlar, T K; von Toerne, E; Severini, H; Skubic, P; Dytman, S A; Mueller, J A; Nam, S; Savinov, V

    2005-05-20

    Using the CLEO detector at the Cornell Electron Storage Ring, we have studied the distribution of kinematic variables in the decay lambda(+)(c)lambda--> e(+)nu(e). By performing a four-dimensional maximum likelihood fit, we determine the form factor ratio, R= f(2)/f(1) = -0.31 +/- 0.05(stat) +/- 0.04(syst), the pole mass, M(pole) = [2.21 +/- 0.08(stat) +/- 0.14(syst)] GeV/c(2), and the decay asymmetry parameter of the lambda(+)(c), alpha (lambda(c)) = -0.86 +/-0.03(stat) +/- 0.02(syst), for q(2) = 0.67 (GeV/c(2))(2). We compare the angular distributions of the lambda(+)(c) and lambda(-)(c) and find no evidence for CP violation: A(lambda(c)) = (alpha(lambda(c)) + alpha (lambda(c)))/(alpha(lambda(c))-alpha(lambda(c))) = 0.00 +/- 0.03(stat) +/- 0.01(syst) +/- 0.02, where the third error is from the uncertainty in the world average of the CP-violating parameter, A(lambda), for ppi(-).

  1. Singlet Fission via an Excimer-Like Intermediate in 3,6-Bis(thiophen-2-yl)diketopyrrolopyrrole Derivatives.

    PubMed

    Mauck, Catherine M; Hartnett, Patrick E; Margulies, Eric A; Ma, Lin; Miller, Claire E; Schatz, George C; Marks, Tobin J; Wasielewski, Michael R

    2016-09-14

    Singlet fission (SF) in polycrystalline thin films of four 3,6-bis(thiophen-2-yl)diketopyrrolopyrrole (TDPP) chromophores with methyl (Me), n-hexyl (C6), triethylene glycol (TEG), and 2-ethylhexyl (EH) substituents at the 2,5-positions is found to involve an intermediate excimer-like state. The four different substituents yield four distinct intermolecular packing geometries, resulting in variable intermolecular charge transfer (CT) interactions in the solid. SF from the excimer state of Me, C6, TEG, and EH takes place in τSF = 22, 336, 195, and 1200 ps, respectively, to give triplet yields of 200%, 110%, 110%, and 70%, respectively. The transient spectra of the excimer-like state and its energetic proximity to the lowest excited singlet state in these derivatives suggests that this state may be the multiexciton (1)(T1T1) state that precedes formation of the uncorrelated triplet excitons. The excimer decay rates correlate well with the SF efficiencies and the degree of intermolecular donor-acceptor interactions resulting from π-stacking of the thiophene donor of one molecule with the DPP core acceptor in another molecule as observed in the crystal structures. Such interactions are found to also increase with the SF coupling energies, as calculated for each derivative. These structural and spectroscopic studies afford a better understanding of the electronic interactions that enhance SF in chromophores having strong intra- and intermolecular CT character.

  2. Perspectives of using the 223-nm wavelength of the KrCl excimer laser for refractive surgery and for the treatment of some eye diseases

    NASA Astrophysics Data System (ADS)

    Bagayev, Sergei N.; Chernikh, Valery V.; Razhev, Alexander M.; Zhupikov, Andrey A.

    2000-06-01

    The new surgical UV ophthalmic laser system Medilex based on the KrCl (223 nm) excimer laser for refractive surgery was created. The comparative analysis of using the UV ophthalmic laser systems Medilex based on the ArF (193 nm) and the KrCl (223 nm) excimer lasers for the correction of refractive errors was performed. The system with the radiation wavelength of 223 nanometer of the KrCl excimer laser for refractive surgery was shown to have several medical and technical advantages over the system with the traditionally used radiation wavelength of 193 nanometer of the ArF excimer laser. In addition the use of the wavelength of 223 nanometer extends functional features of the system, allowing to make not only standard for this type systems surgical and therapeutic procedures but also to treat such ocular diseases as the glaucoma and herpetic keratities. For the UV ophthalmic laser systems Medilex three variations of the beam delivery system including special rotating masks and different beam homogenize systems were developed. All created beam delivery systems are able to make the correction of myopia, hyperopia, astigmatism and myopic or hyperopic astigmatism and may be used for therapeutic procedures. The results of the initial treatments of refractive error corrections using the UV ophthalmic laser systems Medilex for both photorefractive keratectomy (PRK) and LASIK procedures are presented.

  3. Material Processing Opportunites Utilizing a Free Electron Laser

    NASA Astrophysics Data System (ADS)

    Todd, Alan

    1996-11-01

    Many properties of photocathode-driven Free Electron Lasers (FEL) are extremely attractive for material processing applications. These include: 1) broad-band tunability across the IR and UV spectra which permits wavelength optimization, depth deposition control and utilization of resonance phenomena; 2) picosecond pulse structure with continuous nanosecond spacing for optimum deposition efficiency and minimal collateral damage; 3) high peak and average radiated power for economic processing in quantity; and 4) high brightness for spatially defined energy deposition and intense energy density in small spots. We discuss five areas: polymer, metal and electronic material processing, micromachining and defense applications; where IR or UV material processing will find application if the economics is favorable. Specific examples in the IR and UV, such as surface texturing of polymers for improved look and feel, and anti-microbial food packaging films, which have been demonstrated using UV excimer lamps and lasers, will be given. Unfortunately, although the process utility is readily proven, the power levels and costs of lamps and lasers do not scale to production margins. However, from these examples, application specific cost targets ranging from 0.1=A2/kJ to 10=A2/kJ of delivered radiation at power levels from 10 kW to 500 kW, have been developed and are used to define strawman FEL processing systems. Since =46EL radiation energy extraction from the generating electron beam is typically a few percent, at these high average power levels, economic considerations dictate the use of a superconducting RF accelerator with energy recovery to minimize cavity and beam dump power loss. Such a 1 kW IR FEL, funded by the US Navy, is presently under construction at the Thomas Jefferson National Accelerator Facility. This dual-use device, scheduled to generate first light in late 1997, will test both the viability of high-power FELs for shipboard self-defense against cruise missiles, and for the first time, provide an industrial testbed capable of processing various materials in market evaluation quantities.

  4. Observation of B{sup 0}{yields}{lambda}{lambda}K{sup 0} and B{sup 0}{yields}{lambda}{lambda}K*{sup 0} at Belle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Y.-W.; Wang, M.-Z.; Chao, Y.

    2009-03-01

    We study the charmless decays B{yields}{lambda}{lambda}h, where h stands for {pi}{sup +}, K{sup +}, K{sup 0},K*{sup +}, or K*{sup 0}, using a 605 fb{sup -1} data sample collected at the {upsilon}(4S) resonance with the Belle detector at the KEKB asymmetric energy e{sup +}e{sup -} collider. We observe B{sup 0}{yields}{lambda}{lambda}K{sup 0} and B{sup 0}{yields}{lambda}{lambda}K*{sup 0} with branching fractions of (4.76{sub -0.68}{sup +0.84}(stat){+-}0.61(syst))x10{sup -6} and (2.46{sub -0.72}{sup +0.87}{+-}0.34)x10{sup -6}, respectively. The significances of these signals in the threshold-mass enhanced mass region, M{sub {lambda}}{sub {lambda}}<2.85 GeV/c{sup 2}, are 12.4{sigma} and 9.3{sigma}, respectively. We also update the branching fraction B(B{sup +}{yields}{lambda}{lambda}K{sup +})=(3.38{sub -0.36}{sup +0.41}{+-}0.41)x10{supmore » -6} with better accuracy, and report the following measurement or 90% confidence level upper limit in the threshold-mass-enhanced region: B(B{sup +}{yields}{lambda}{lambda}K*{sup +})=(2.19{sub -0.88}{sup +1.13}{+-}0.33)x10{sup -6} with 3.7{sigma} significance; B(B{sup +}{yields}{lambda}{lambda}{pi}{sup +})<0.94x10{sup -6}. A related search for B{sup 0}{yields}{lambda}{lambda}D{sup 0} yields a branching fraction B(B{sup 0}{yields}{lambda}{lambda}D{sup 0})=(1.05{sub -0.44}{sup +0.57}{+-}0.14)x10{sup -5}. This may be compared with the large, {approx}10{sup -4}, branching fraction observed for B{sup 0}{yields}ppD{sup 0}. The M{sub {lambda}}{sub {lambda}} enhancements near threshold and related angular distributions for the observed modes are also reported.« less

  5. Initiation of lambda DNA replication. The Escherichia coli small heat shock proteins, DnaJ and GrpE, increase DnaK's affinity for the lambda P protein.

    PubMed

    Osipiuk, J; Georgopoulos, C; Zylicz, M

    1993-03-05

    It is known that the initiation of bacteriophage lambda replication requires the orderly assembly of the lambda O.lambda P.DnaB helicase protein preprimosomal complex at the ori lambda DNA site. The DnaK, DnaJ, and GrpE heat shock proteins act together to destabilize the lambda P.DnaB complex, thus freeing DnaB and allowing it to unwind lambda DNA near the ori lambda site. The first step of this disassembly reaction is the binding of DnaK to the lambda P protein. In this report, we examined the influence of the DnaJ and GrpE proteins on the stability of the lambda P.DnaK complex. We present evidence for the existence of the following protein-protein complexes: lambda P.DnaK, lambda P.DnaJ, DnaJ.DnaK, DnaK.GrpE, and lambda P.DnaK.GrpE. Our results suggest that the presence of GrpE alone destabilizes the lambda P.DnaK complex, whereas the presence of DnaJ alone stabilizes the lambda P.DnaK complex. Using immunoprecipitation, we show that in the presence of GrpE, DnaK exhibits a higher affinity for the lambda P.DnaJ complex than it does alone. Using cross-linking with glutaraldehyde, we show that oligomeric forms of DnaK exhibit a higher affinity for lambda P than monomeric DnaK. However, in the presence of GrpE, monomeric DnaK can efficiently bind lambda P protein. These findings help explain our previous results, namely that in the GrpE-dependent lambda DNA replication system, the DnaK protein requirement can be reduced up to 10-fold.

  6. Physical interactions between bacteriophage and Escherichia coli proteins required for initiation of lambda DNA replication.

    PubMed

    Liberek, K; Osipiuk, J; Zylicz, M; Ang, D; Skorko, J; Georgopoulos, C

    1990-02-25

    The process of initiation of lambda DNA replication requires the assembly of the proper nucleoprotein complex at the origin of replication, ori lambda. The complex is composed of both phage and host-coded proteins. The lambda O initiator protein binds specifically to ori lambda. The lambda P initiator protein binds to both lambda O and the host-coded dnaB helicase, giving rise to an ori lambda DNA.lambda O.lambda P.dnaB structure. The dnaK and dnaJ heat shock proteins have been shown capable of dissociating this complex. The thus freed dnaB helicase unwinds the duplex DNA template at the replication fork. In this report, through cross-linking, size chromatography, and protein affinity chromatography, we document some of the protein-protein interactions occurring at ori lambda. Our results show that the dnaK protein specifically interacts with both lambda O and lambda P, and that the dnaJ protein specifically interacts with the dnaB helicase.

  7. Bound-bound transitions in the emission spectra of Ba+-He excimer

    NASA Astrophysics Data System (ADS)

    Moroshkin, P.; Kono, K.

    2016-05-01

    We present an experimental and theoretical study of the emission and absorption spectra of the Ba+ ions and Ba+*He excimer quasimolecules in the cryogenic Ba-He plasma. We observe several spectral features in the emission spectrum, which we assign to the electronic transitions between bound states of the excimer correlating to the 6 2P3 /2 and 5 2D3 /2 ,5 /2 states of Ba+. The resulting Ba+(5 2DJ) He is a metastable electronically excited complex with orbital angular momentum L =2 , thus expanding the family of known metal-helium quasimolecules. It might be suitable for high-resolution spectroscopic studies and for the search for new polyatomic exciplex structures.

  8. 0.35-μm excimer DUV photolithography process

    NASA Astrophysics Data System (ADS)

    Arugu, Donald O.; Green, Kent G.; Nunan, Peter D.; Terbeek, Marcel; Crank, Sue E.; Ta, Lam; Capsuto, Elliott S.; Sethi, Satyendra S.

    1993-08-01

    It is becoming increasingly clear that DUV excimer laser based imaging will be one of the technologies for printing sub-half micron devices. This paper reports the investigation of 0.35 micrometers photolithography process using chemically amplified DUV resists on organic anti- reflective coating (ARC). Production data from the GCA XLS excimer DUV tools with nominal gate width of 0.35 micrometers lines, 0.45 micrometers spaces was studied to demonstrate device production worthiness. This data included electrical yield information for device characterization. Exposure overlay was done by mixing and matching DUV and I-line GCA steppers for critical and non critical levels respectively. Working isolated transistors down to 0.2 micrometers have been demonstrated.

  9. Ablation algorithms and corneal asphericity in myopic correction with excimer lasers

    NASA Astrophysics Data System (ADS)

    Iroshnikov, Nikita G.; Larichev, Andrey V.; Yablokov, Michail G.

    2007-06-01

    The purpose of this work is studying a corneal asphericity change after a myopic refractive correction by mean of excimer lasers. As the ablation profile shape plays a key role in the post-op corneal asphericity, ablation profiles of recent lasers should be studied. The other task of this research was to analyze operation (LASIK) outcomes of one of the lasers with generic spherical ablation profile and to compare an asphericity change with theoretical predictions. The several correction methods, like custom generated aspherical profiles, may be utilized for mitigation of unwanted effects of asphericity change. Here we also present preliminary results of such correction for one of the excimer lasers.

  10. Structures and Binding Energies of the Naphthalene Dimer in Its Ground and Excited States.

    PubMed

    Dubinets, N O; Safonov, A A; Bagaturyants, A A

    2016-05-05

    Possible structures of the naphthalene dimer corresponding to local energy minima in the ground and excited (excimer) electronic states are comprehensively investigated using DFT-D and TDDFT-D methods with a special accent on the excimer structures. The corresponding binding and electronic transition energies are calculated, and the nature of the electronic states in different structures is analyzed. Several parallel (stacked) and T-shaped structures were found in both the ground and excited (excimer) states in a rather narrow energy range. The T-shaped structure with the lowest energy in the excited state exhibits a marked charge transfer from the upright molecule to the base one.

  11. Tables of Transition Probabilities and Branching Ratios for Electric Dipole Transitions Between Arbitrary Levels of Hydrogen-Like Atoms

    NASA Technical Reports Server (NTRS)

    Omidvar, K.

    1980-01-01

    Branching ratios in hydrogen-like atoms due to electric-dipole transitions are tabulated for the initial principal and angular momentum quantum number n, lambda, and final principal and angular momentum quantum numbers n, lambda. In table 1, transition probabilities are given for transitions n, lambda, yields n, where sums have been made with respect to lambda. In this table, 2 or = n' or = 10, o or = lambda' or = n'-1, and 1 or = n or = n'-1. In addition, averages with respect to lambda' and sums with respect to n, and lifetimes are given. In table 2, branching ratios are given for transitions n' lambda' yields ni, where sums have been made with respect to lambda. In these tables, 2 or = n' or = 10, 0 or = lambda', n'-1, and 1 or = n or = n'-1. Averages with respect to lambda' are also given. In table 3, branching ratios are given for transitions n' lambda' yields in lambda, where 1 or = n or = 5, 0 or = lambda or = n-1, n n' or = 15, and 0 or = lambda' or = n(s), where n(s), is the smaller of the two numbers n'-1 and 6. Averages with respect to lambda' are given.

  12. Measurement of the Λ b cross section and the Λ ¯ b to Λ b ratio with J / ψ Λ decays in pp collisions at s = 7 TeV

    DOE PAGES

    Chatrchyan, S.; Khachatryan, V.; Sirunyan, A. M.; ...

    2012-05-31

    The Lambda(b) differential production cross section and the cross section ratio anti-Lambda(b)/Lambda(b) are measured as functions of transverse momentum pt(Lambda(b)) and rapidity abs(y(Lambda(b))) in pp collisions at sqrt(s) = 7 TeV using data collected by the CMS experiment at the LHC. The measurements are based on Lambda(b) decays reconstructed in the exclusive final state J/Psi Lambda, with the subsequent decays J/Psi to an opposite-sign muon pair and Lambda to proton pion, using a data sample corresponding to an integrated luminosity of 1.9 inverse femtobarns. The product of the cross section times the branching ratio for Lambda(b) to J/Psi Lambda versusmore » pt(Lambda(b)) falls faster than that of b mesons. The measured value of the cross section times the branching ratio for pt(Lambda(b)) > 10 GeV and abs(y(Lambda(b))) < 2.0 is 1.06 +/- 0.06 +/- 0.12 nb, and the integrated cross section ratio for anti-Lambda(b)/Lambda(b) is 1.02 +/- 0.07 +/- 0.09, where the uncertainties are statistical and systematic, respectively.« less

  13. {lambda}{sub b}{yields}p, {lambda} transition form factors from QCD light-cone sum rules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang Yuming; Lue Caidian; Shen Yuelong

    2009-10-01

    Light-cone sum rules for the {lambda}{sub b}{yields}p, {lambda} transition form factors are derived from the correlation functions expanded by the twist of the distribution amplitudes of the {lambda}{sub b} baryon. In terms of the {lambda}{sub b} three-quark distribution amplitude models constrained by the QCD theory, we calculate the form factors at small momentum transfers and compare the results with those estimated in the conventional light-cone sum rules (LCSR) and perturbative QCD approaches. Our results indicate that the two different versions of sum rules can lead to the consistent numbers of form factors responsible for {lambda}{sub b}{yields}p transition. The {lambda}{sub b}{yields}{lambda}more » transition form factors from LCSR with the asymptotic {lambda} baryon distribution amplitudes are found to be almost 1 order larger than those obtained in the {lambda}{sub b}-baryon LCSR, implying that the preasymptotic corrections to the baryonic distribution amplitudes are of great importance. Moreover, the SU(3) symmetry breaking effects between the form factors f{sub 1}{sup {lambda}{sub b}}{sup {yields}}{sup p} and f{sub 1}{sup {lambda}{sub b}}{sup {yields}}{sup {lambda}} are computed as 28{sub -8}{sup +14}% in the framework of {lambda}{sub b}-baryon LCSR.« less

  14. First observation and measurement of the resonant structure of the lambda_b->lambda_c pi-pi+pi- decay mode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Azzurri, P.; Barria, P.; Ciocci, M.A.

    The authors present the first observation of the {Lambda}{sub b}{sup 0} {yields} {Lambda}{sub c}{sup +}{pi}{sup -}{pi}{sup +}{pi}{sup -} decay using data from an integrated luminosity of approximately 2.4 fb{sup -1} of p{bar p} collisions at {radical}s = 1.96 TeV, collected with the CDF II detector at the Fermilab Tevatron. They also present the first observation of the resonant decays {Lambda}{sub b}{sup 0} {yields} {Sigma}{sub c}(2455){sup 0} {pi}{sup +}{pi}{sup -} {yields} {Lambda}{sub c}{sup +}{pi}{sup -}{pi}{sup +}{pi}{sup -}, {Lambda}{sub b}{sup 0} {yields} {Sigma}{sub c}(2455){sup ++}{pi}{sup -}{pi}{sup -} {yields} {Lambda}{sub c}{sup +}{pi}{sup -}{pi}{sup +}{pi}{sup -}, {Lambda}{sub b}{sup 0} {yields} {Lambda}{sub c}(2595){sup +}{pi}{sup -}more » {yields} {Lambda}{sub c}{sup +}{pi}{sup -}{pi}{sup +}{pi}{sup -} and {Lambda}{sub b}{sup 0} {yields} {Lambda}{sub c}(2625){sup +}{pi}{sup -} {yields} {Lambda}{sub c}{sup +}{pi}{sup -}{pi}{sup +}{pi}{sup -}, and measure their relative branching ratios.« less

  15. Spin correlations in the {Lambda}{Lambda} and {Lambda}{Lambda}-bar systems generated in relativistic heavy-ion collisions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lyuboshitz, V. L.; Lyuboshitz, V. V., E-mail: Valery.Lyuboshitz@jinr.r

    2010-05-15

    Spin correlations for the {Lambda}{Lambda} and {Lambda}{Lambda}-bar pairs, generated in relativistic heavy-ion collisions, and related angular correlations at the joint registration of hadronic decays of two hyperons, in which space parity is not conserved, are analyzed. The correlation tensor components can be derived from the double angular distribution of products of two decays by the method of 'moments'. The properties of the 'trace' of the correlation tensor (a sum of three diagonal components), determining the relative fractions of the triplet states and singlet state of respective pairs, are discussed. Spin correlations for two identical particles ({Lambda}{Lambda}) and two nonidentical particlesmore » ({Lambda}{Lambda}-bar) are considered from the viewpoint of the conventional model of one-particle sources. In the framework of this model, correlations vanish at sufficiently large relative momenta. However, under these conditions, in the case of two nonidentical particles ({Lambda}{Lambda}-bar) a noticeable role is played by two-particle annihilation (two-quark, two-gluon) sources, which lead to the difference of the correlation tensor from zero. In particular, such a situation may arise when the system passes through the 'mixed phase.'« less

  16. Pustular Palmoplantar Psoriasis Successfully Treated with Nb-UVB Monochromatic Excimer Light: A Case-Report.

    PubMed

    Gianfaldoni, Serena; Tchernev, Georgi; Wollina, Uwe; Lotti, Torello

    2017-07-25

    Barber's palmoplantar pustulosis (PPP) is a form of localised pustular psoriasis, affecting the palmar and plantar surfaces. It is a chronic disease, with a deep impact on the patients' quality of life. The Authors discuss a case of Baber Psoriasis successfully treated with monochromatic excimer light.

  17. Pustular Palmoplantar Psoriasis Successfully Treated with Nb-UVB Monochromatic Excimer Light: A Case-Report

    PubMed Central

    Gianfaldoni, Serena; Tchernev, Georgi; Wollina, Uwe; Lotti, Torello

    2017-01-01

    Barber’s palmoplantar pustulosis (PPP) is a form of localised pustular psoriasis, affecting the palmar and plantar surfaces. It is a chronic disease, with a deep impact on the patients’ quality of life. The Authors discuss a case of Baber Psoriasis successfully treated with monochromatic excimer light. PMID:28785333

  18. Excimer laser assisted very fast exfoliation and reduction of graphite oxide at room temperature under air ambient for Supercapacitors electrode

    NASA Astrophysics Data System (ADS)

    Malek Hosseini, S. M. B.; Baizaee, S. M.; Naderi, Hamid Reza; Dare Kordi, Ali

    2018-01-01

    Excimer laser was used for reduction and exfoliation of graphite oxide (GO) at room temperature under air ambient. The prepared excimer laser reduced graphite oxide (XLRGO) is characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM), nitrogen adsorption/desorption (BET method), X-ray diffraction (XRD), X-ray photoemission spectroscopy (XPS), Fourier transform infrared spectroscopy (FTIR) and UV-vis absorption techniques for surface, structural functional groups and band gap analysis. Electrochemical properties are investigated using cyclic voltammetry, galvanostatic charge-discharge, electrochemical impedance spectroscopy (EIS) and continues cyclic voltammetry (CCV) in 0.5 M Na2SO4 as electrolyte. Electrochemical investigations revealed that XLRGO electrode has enhanced supercapacitive performance including specific capacitance of 299 F/g at a scan rate of 2 mV/s. Furthermore, CCV measurement showed that XLRGO electrode kept 97.8% of its initial capacitance/capacity after 4000 cycles. The obtained results from electrochemical investigations confirm that the reduction of GO by using an excimer laser produces high-quality graphene for supercapacitor applications without the need for additional operations.

  19. Trace detection of organic compounds in complex sample matrixes by single photon ionization ion trap mass spectrometry: real-time detection of security-relevant compounds and online analysis of the coffee-roasting process.

    PubMed

    Schramm, Elisabeth; Kürten, Andreas; Hölzer, Jasper; Mitschke, Stefan; Mühlberger, Fabian; Sklorz, Martin; Wieser, Jochen; Ulrich, Andreas; Pütz, Michael; Schulte-Ladbeck, Rasmus; Schultze, Rainer; Curtius, Joachim; Borrmann, Stephan; Zimmermann, Ralf

    2009-06-01

    An in-house-built ion trap mass spectrometer combined with a soft ionization source has been set up and tested. As ionization source, an electron beam pumped vacuum UV (VUV) excimer lamp (EBEL) was used for single-photon ionization. It was shown that soft ionization allows the reduction of fragmentation of the target analytes and the suppression of most matrix components. Therefore, the combination of photon ionization with the tandem mass spectrometry (MS/MS) capability of an ion trap yields a powerful tool for molecular ion peak detection and identification of organic trace compounds in complex matrixes. This setup was successfully tested for two different applications. The first one is the detection of security-relevant substances like explosives, narcotics, and chemical warfare agents. One test substance from each of these groups was chosen and detected successfully with single photon ionization ion trap mass spectrometry (SPI-ITMS) MS/MS measurements. Additionally, first tests were performed, demonstrating that this method is not influenced by matrix compounds. The second field of application is the detection of process gases. Here, exhaust gas from coffee roasting was analyzed in real time, and some of its compounds were identified using MS/MS studies.

  20. UTILIZING SYNTHETIC UV SPECTRA TO EXPLORE THE PHYSICAL BASIS FOR THE CLASSIFICATION OF LAMBDA BOÖTIS STARS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, Kwang-Ping; Johnson, Dustin M.; Tarbell, Erik S.

    2016-04-15

    Lambda Boo-type stars are a group of late B to early F-type Population I dwarfs that show mild to extreme deficiencies of iron-peak elements (up to 2 dex), but their C, N, O, and S abundances are near solar. This intriguing stellar class has recently regained the spotlight because of the directly imaged planets around a confirmed Lambda Boo star, HR 8799, and a suggested Lambda Boo star, Beta Pictoris. The discovery of a giant asteroid belt around Vega, another possible Lambda Boo star, also suggests hidden planets. The possible link between Lambda Boo stars and planet-bearing stars motivates usmore » to study Lambda Boo stars systematically. Since the peculiar nature of the prototype Lambda Boötis was first noticed in 1943, Lambda Boo candidates published in the literature have been selected using widely different criteria. In order to determine the origin of Lambda Boo stars’ unique abundance pattern and to better discriminate between theories explaining the Lambda Boo phenomenon, a consistent working definition of Lambda Boo stars is needed. We have re-evaluated all published Lambda Boo candidates and their available ultraviolet and visible spectra. In this paper, using observed and synthetic spectra, we explore the physical basis for the classification of Lambda Boo stars, and develop quantitative criteria that discriminate metal-poor stars from bona fide Lambda Boo stars. Based on these stricter Lambda Boo classification criteria, we conclude that neither Beta Pictoris nor Vega should be classified as Lambda Boo stars.« less

  1. Bivariate- distribution for transition matrix elements in Breit-Wigner to Gaussian domains of interacting particle systems.

    PubMed

    Kota, V K B; Chavda, N D; Sahu, R

    2006-04-01

    Interacting many-particle systems with a mean-field one-body part plus a chaos generating random two-body interaction having strength lambda exhibit Poisson to Gaussian orthogonal ensemble and Breit-Wigner (BW) to Gaussian transitions in level fluctuations and strength functions with transition points marked by lambda = lambda c and lambda = lambda F, respectively; lambda F > lambda c. For these systems a theory for the matrix elements of one-body transition operators is available, as valid in the Gaussian domain, with lambda > lambda F, in terms of orbital occupation numbers, level densities, and an integral involving a bivariate Gaussian in the initial and final energies. Here we show that, using a bivariate-t distribution, the theory extends below from the Gaussian regime to the BW regime up to lambda = lambda c. This is well tested in numerical calculations for 6 spinless fermions in 12 single-particle states.

  2. Correlation Measurement of Lambda-anti-Lambda, Lambda-Lambda and anti-Lambda-anti-Lambda with the ATLAS detector at s=7 TeV

    NASA Astrophysics Data System (ADS)

    Cheng, Hok-Chuen

    This thesis summaries the measurements of correlations between Lambda 0Lambda0, Lambda0Lambda 0, and Lambda0Lambda 0 hyperon pairs produced inclusively at the LHC, which are useful for a better understanding of the quark-antiquark pair production and jet fragmentation and hadronization processes. The analysis is based on hyperon pairs selected using the muon and minimum bias data samples collected at the ATLAS experiment from proton-proton collisions at a center-of-mass energy of 7 TeV in 2010. Excess Lambda0Lambda 0 are observed near the production threshold and are identified to be originated from the parton system in the string model in the MC sample, decaying either directly or through heavy strange resonances such as Sigma0 and Sigma*(1385). Dynamical correlations have been explored through a correlation function defined as the ratio of two-particle to single-particle densities. Positive correlation is observed for Lambda0Lambda0 and anticorrelation is observed for Lambda0Lambda 0 and Lambda0Lambda 0 for Q in [0,2] GeV. The structure replicates similar correlations in pp, pp, and pppp events in PYTHIA generator as predicted by the Lund string fragmentation model. Parameters of the "popcorn" mechanism implemented in the PYTHIA generator are tuned and are found to have little impact on the structure observed. The spin composition of the sample is extracted using a data-driven reference sample built by event mixing. Appropriate corrections have been made to the kinematic distributions in the reference sample by kinematic weighting to make sure that the detector effects are well modeled. A modified Pearson's chi2 test statistics is calculated for the costheta* distribution to determine the best-fitted A-value for data. The results are consistent with zero for both like-type and unlike-type hyperon pairs in Q ∈ [0,10] GeV and Q ∈ [1,10] GeV respectively. The data statistics in the range of Q ∈ [0, 1] GeV is currently too low for the estimation of the emitter size for Fermi-Dirac correlation.

  3. Vacuum barrier for excimer lasers

    DOEpatents

    Shurter, Roger P.

    1992-01-01

    A barrier for separating the vacuum area of a diode from the pressurized gas area of an excimer laser. The barrier is a composite material comprising layers of a metal such as copper, along with layers of polyimide, and a matrix of graphite fiber yarns impregnated with epoxy. The barrier is stronger than conventional foil barriers, and allows greater electron throughput.

  4. Management of central venous gradient using excimer laser lead extraction of chronic indwelling pacemaker leads in the setting of ipsilateral arteriovenous fistula.

    PubMed

    Ramirez, Alexies; Gentlesk, Philip J; Peele, Mark E; Eckart, Robert E

    2012-07-01

    Device therapy is becoming common in those patients with renal insufficiency. Coexisting need for arteriovenous (AV) fistula placement is often contemplated relative to device placement. We describe the excimer laser lead extraction of a malfunctioning chronic atrial pacemaker lead ipsilateral to an AV fistula.

  5. Laser- and Particle-Beam Chemical Processes on Surfaces. Volume 129

    DTIC Science & Technology

    1989-12-26

    explosive decomposition of organometallic compounds with single pulse laser irradiation . This new... ultrashort , meaning ultra high intensity , excimer laser pulses , two-photon absorption becomes important and limits the penetration depth of the laser ...requires a higher photon load before suffering damage to its chemical structure. With extremely high light intensities , ultrashort excimer laser pulses

  6. Comparing laser induced plasmas formed in diode and excimer pumped alkali lasers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Markosyan, Aram H.

    Here, lasing on the D 1 transition (6 2P 1/2 → 6 2S 1/2) of cesium can be reached in both diode and excimer pumped alkali lasers. The first uses D 2 transition (6 2S 1/2 → 6 2P 3/2) for pumping, whereas the second is pumped by photoexcitation of ground state Cs-Ar collisional pairs and subsequent dissociation of diatomic, electronically-excited CsAr molecules (excimers). Despite lasing on the same D 1 transition, differences in pumping schemes enables chemical pathways and characteristic timescales unique for each system. We investigate unavoidable plasma formation during operation of both systems side by side inmore » Ar/C 2H 6/Cs.« less

  7. Polycrystalline silicon thin-film transistors with location-controlled crystal grains fabricated by excimer laser crystallization

    NASA Astrophysics Data System (ADS)

    Tsai, Chun-Chien; Lee, Yao-Jen; Chiang, Ko-Yu; Wang, Jyh-Liang; Lee, I.-Che; Chen, Hsu-Hsin; Wei, Kai-Fang; Chang, Ting-Kuo; Chen, Bo-Ting; Cheng, Huang-Chung

    2007-11-01

    In this paper, location-controlled silicon crystal grains are fabricated by the excimer laser crystallization method which employs amorphous silicon spacer structure and prepatterned thin films. The amorphous silicon spacer in nanometer-sized width formed using spacer technology is served as seed crystal to artificially control superlateral growth phenomenon during excimer laser irradiation. An array of 1.8-μm-sized disklike silicon grains is formed, and the n-channel thin-film transistors whose channels located inside the artificially-controlled crystal grains exhibit higher performance of field-effect-mobility reaching 308cm2/Vs as compared with the conventional ones. This position-manipulated silicon grains are essential to high-performance and good uniformity devices.

  8. Excimer laser phototherapeutic keratectomy for shield ulcers and corneal plaques in vernal keratoconjunctivitis.

    PubMed

    Cameron, J A; Antonios, S R; Badr, I A

    1995-01-01

    Shield-shaped corneal ulcers and corneal plaques in vernal keratoconjunctivitis are associated with delayed epithelial healing, as well as the risks of infectious keratitis and sterile stromal ulceration. Significant visual impairment due to scarring and irregular astigmatism may result from central corneal lesions. Three eyes with central corneal lesions resulting from vernal keratoconjunctivitis were treated by excimer laser after active vernal keratoconjunctivitis was controlled and inflammatory plaque overlying the shield ulcers was removed. All three eyes showed rapid reepithelialization within 1 week. Spectacle-corrected visual acuity of 20/30 or better was obtained in each eye. In selected patients, excimer laser phototherapeutic keratectomy may be a useful adjunct in the treatment of shield-shaped corneal ulcers and plaques in vernal keratoconjunctivitis.

  9. High efficiency and stable white OLED using a single emitter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Jian

    2016-01-18

    The ultimate objective of this project was to demonstrate an efficient and stable white OLED using a single emitter on a planar glass substrate. The focus of the project is on the development of efficient and stable square planar phosphorescent emitters and evaluation of such class of materials in the device settings. Key challenges included improving the emission efficiency of molecular dopants and excimers, controlling emission color of emitters and their excimers, and improving optical and electrical stability of emissive dopants. At the end of this research program, the PI has made enough progress to demonstrate the potential of excimer-basedmore » white OLED as a cost-effective solution for WOLED panel in the solid state lighting applications.« less

  10. Comparing laser induced plasmas formed in diode and excimer pumped alkali lasers

    DOE PAGES

    Markosyan, Aram H.

    2018-01-05

    Here, lasing on the D 1 transition (6 2P 1/2 → 6 2S 1/2) of cesium can be reached in both diode and excimer pumped alkali lasers. The first uses D 2 transition (6 2S 1/2 → 6 2P 3/2) for pumping, whereas the second is pumped by photoexcitation of ground state Cs-Ar collisional pairs and subsequent dissociation of diatomic, electronically-excited CsAr molecules (excimers). Despite lasing on the same D 1 transition, differences in pumping schemes enables chemical pathways and characteristic timescales unique for each system. We investigate unavoidable plasma formation during operation of both systems side by side inmore » Ar/C 2H 6/Cs.« less

  11. Pulsed excimer laser processing

    NASA Technical Reports Server (NTRS)

    Wong, D.

    1985-01-01

    The status of pulsed excimer laser processing of PV cells is presented. The cost effective feasibility of fabricating high efficiency solar cells on Czochralski wafers using a pulsed excimer laser for junction formation, surface passivation, and front metallization. Laser annealing results were promising with the best AR coated cell having an efficiency of 16.1%. Better results would be expected with larger laser spot size because there was some degradation in open circuit voltage caused by laser spot overlap and edge effects. Surface heating and photolytic decomposition by the laser was used to deposit tungsten from the reaction of tungsten hexafluoride and hydrogen. The line widths were 5 to 10 mils, and the depositions passed the tape adhesion test. Thinner lines are practical using an optimized optical system.

  12. Comparing laser induced plasmas formed in diode and excimer pumped alkali lasers.

    PubMed

    Markosyan, Aram H

    2018-01-08

    Lasing on the D 1 transition (6 2 P 1/2 → 6 2 S 1/2 ) of cesium can be reached in both diode and excimer pumped alkali lasers. The first uses D 2 transition (6 2 S 1/2 → 6 2 P 3/2 ) for pumping, whereas the second is pumped by photoexcitation of ground state Cs-Ar collisional pairs and subsequent dissociation of diatomic, electronically-excited CsAr molecules (excimers). Despite lasing on the same D 1 transition, differences in pumping schemes enables chemical pathways and characteristic timescales unique for each system. We investigate unavoidable plasma formation during operation of both systems side by side in Ar/C 2 H 6 /Cs.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akaishi, Yoshinori; College of Science and Technology, Nihon University, Funabashi 274-8501; Myint, Khin Swe

    The overbinding problem of {sub {lambda}}{sup 5}He is solved by introducing a concept of coherent {lambda}-{sigma} coupling which is equivalent to a {lambda}NN three-body force. This three-body force is coherently enhanced in the 0{sup +} states of {sub {lambda}}{sup 4}H and {sub {lambda}}{sup 4}He. The 0{sup +}-1{sup +} splitting in these hypernuclei is mainly due to coherent {lambda}-{sigma} coupling and partly due to the {lambda}N spin-spin interaction. A {lambda}NN three-body potential is derived from the coupled-channel treatment. The origin of the repulsive and attractive nature of the three-body force is discussed. Coherent {lambda}-{sigma} coupling becomes more important in neutron-rich hypernucleimore » and especially in neutron-star matter at high densities. The possible existence of ''hyperheavy hydrogen'', {sub {lambda}}{sup 6}H, is suggested.« less

  14. Role of the Escherichia coli grpE heat shock protein in the initiation of bacteriophage lambda DNA replication.

    PubMed

    Osipiuk, J; Zylicz, M

    1991-01-01

    Initiation of replication of lambda DNA requires assembly of the proper nucleoprotein complex consisting of the lambda origin of replication-lambda O-lambda P-dnaB proteins. The dnaJ, dnaK and grpE heat shock proteins destabilize the lambda P-dnaB interaction in this complex permitting dnaB helicase to unwind lambda DNA near ori lambda sequence. First step of this disassembling reaction is the binding of dnaK protein to lambda P protein. In this report we examined the influence of dnaJ and grpE proteins on stability of the lambda P-dnaK complex. Our results show that grpE alone dissociates this complex, but both grpE and dnaJ together do not. These results suggest that, in the presence of grpE protein, dnaK protein has a higher affinity for lambda P protein complexed with dnaJ protein than in the situation where grpE protein is not used.

  15. Measurement of sigma Lambda b0/sigma B0 x B(Lambda b0-->Lambda c+pi-)/B(B0-->D+pi-) in pp collisions at square root s=1.96 TeV.

    PubMed

    Abulencia, A; Adelman, J; Affolder, T; Akimoto, T; Albrow, M G; Ambrose, D; Amerio, S; Amidei, D; Anastassov, A; Anikeev, K; Annovi, A; Antos, J; Aoki, M; Apollinari, G; Arguin, J-F; Arisawa, T; Artikov, A; Ashmanskas, W; Attal, A; Azfar, F; Azzi-Bacchetta, P; Azzurri, P; Bacchetta, N; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Baroiant, S; Bartsch, V; Bauer, G; Bedeschi, F; Behari, S; Belforte, S; Bellettini, G; Bellinger, J; Belloni, A; Benjamin, D; Beretvas, A; Beringer, J; Berry, T; Bhatti, A; Binkley, M; Bisello, D; Blair, R E; Blocker, C; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bolla, G; Bolshov, A; Bortoletto, D; Boudreau, J; Boveia, A; Brau, B; Brigliadori, L; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Budroni, S; Burkett, K; Busetto, G; Bussey, P; Byrum, K L; Cabrera, S; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carillo, S; Carlsmith, D; Carosi, R; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, I; Cho, K; Chokheli, D; Chou, J P; Choudalakis, G; Chuang, S H; Chung, K; Chung, W H; Chung, Y S; Ciljak, M; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Coca, M; Compostella, G; Convery, M E; Conway, J; Cooper, B; Copic, K; Cordelli, M; Cortiana, G; Crescioli, F; Cuenca Almenar, C; Cuevas, J; Culbertson, R; Cully, J C; Cyr, D; DaRonco, S; D'Auria, S; Davies, T; D'Onofrio, M; Dagenhart, D; de Barbaro, P; De Cecco, S; Deisher, A; De Lentdecker, G; Dell'Orso, M; Delli Paoli, F; Demortier, L; Deng, J; Deninno, M; De Pedis, D; Derwent, P F; Di Giovanni, G P; Dionisi, C; Di Ruzza, B; Dittmann, J R; DiTuro, P; Dörr, C; Donati, S; Donega, M; Dong, P; Donini, J; Dorigo, T; Dube, S; Efron, J; Erbacher, R; Errede, D; Errede, S; Eusebi, R; Fang, H C; Farrington, S; Fedorko, I; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Field, R; Flanagan, G; Foland, A; Forrester, S; Foster, G W; Franklin, M; Freeman, J C; Furic, I; Gallinaro, M; Galyardt, J; Garcia, J E; Garberson, F; Garfinkel, A F; Gay, C; Gerberich, H; Gerdes, D; Giagu, S; Giannetti, P; Gibson, A; Gibson, K; Gimmell, J L; Ginsburg, C; Giokaris, N; Giordani, M; Giromini, P; Giunta, M; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Goldstein, J; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gresele, A; Griffiths, M; Grinstein, S; Grosso-Pilcher, C; Group, R C; Grundler, U; Guimaraes da Costa, J; Gunay-Unalan, Z; Haber, C; Hahn, K; Hahn, S R; Halkiadakis, E; Hamilton, A; Han, B-Y; Han, J Y; Handler, R; Happacher, F; Hara, K; Hare, M; Harper, S; Harr, R F; Harris, R M; Hartz, M; Hatakeyama, K; Hauser, J; Heijboer, A; Heinemann, B; Heinrich, J; Henderson, C; Herndon, M; Heuser, J; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Holloway, A; Hou, S; Houlden, M; Hsu, S-C; Huffman, B T; Hughes, R E; Husemann, U; Huston, J; Incandela, J; Introzzi, G; Iori, M; Ishizawa, Y; Ivanov, A; Iyutin, B; James, E; Jang, D; Jayatilaka, B; Jeans, D; Jensen, H; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Jung, J E; Junk, T R; Kamon, T; Karchin, P E; Kato, Y; Kemp, Y; Kephart, R; Kerzel, U; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kimura, N; Kirsch, L; Klimenko, S; Klute, M; Knuteson, B; Ko, B R; Kondo, K; Kong, D J; Konigsberg, J; Korytov, A; Kotwal, A V; Kovalev, A; Kraan, A C; Kraus, J; Kravchenko, I; Kreps, M; Kroll, J; Krumnack, N; Kruse, M; Krutelyov, V; Kubo, T; Kuhlmann, S E; Kuhr, T; Kusakabe, Y; Kwang, S; Laasanen, A T; Lai, S; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; Le, Y; LeCompte, T; Lee, J; Lee, J; Lee, Y J; Lee, S W; Lefèvre, R; Leonardo, N; Leone, S; Levy, S; Lewis, J D; Lin, C; Lin, C S; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, T; Lockyer, N S; Loginov, A; Loreti, M; Loverre, P; Lu, R-S; Lucchesi, D; Lujan, P; Lukens, P; Lungu, G; Lyons, L; Lys, J; Lysak, R; Lytken, E; Mack, P; MacQueen, D; Madrak, R; Maeshima, K; Makhoul, K; Maki, T; Maksimovic, P; Malde, S; Manca, G; Margaroli, F; Marginean, R; Marino, C; Marino, C P; Martin, A; Martin, M; Martin, V; Martínez, M; Maruyama, T; Mastrandrea, P; Masubuchi, T; Matsunaga, H; Mattson, M E; Mazini, R; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Menzemer, S; Menzione, A; Merkel, P; Mesropian, C; Messina, A; Miao, T; Miladinovic, N; Miles, J; Miller, R; Mills, C; Milnik, M; Mitra, A; Mitselmakher, G; Miyamoto, A; Moed, S; Moggi, N; Mohr, B; Moore, R; Morello, M; Movilla Fernandez, P; Mülmenstädt, J; Mukherjee, A; Muller, Th; Mumford, R; Murat, P; Nachtman, J; Nagano, A; Naganoma, J; Nakano, I; Napier, A; Necula, V; Neu, C; Neubauer, M S; Nielsen, J; Nigmanov, T; Nodulman, L; Norniella, O; Nurse, E; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Oldeman, R; Orava, R; Osterberg, K; Pagliarone, C; Palencia, E; Papadimitriou, V; Paramonov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Piedra, J; Pinera, L; Pitts, K; Plager, C; Pondrom, L; Portell, X; Poukhov, O; Pounder, N; Prakoshyn, F; Pronko, A; Proudfoot, J; Ptohos, F; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Ranjan, N; Rappoccio, S; Reisert, B; Rekovic, V; Renton, P; Rescigno, M; Richter, S; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Ruiz, A; Russ, J; Rusu, V; Saarikko, H; Sabik, S; Safonov, A; Sakumoto, W K; Salamanna, G; Saltó, O; Saltzberg, D; Sánchez, C; Santi, L; Sarkar, S; Sartori, L; Sato, K; Savard, P; Savoy-Navarro, A; Scheidle, T; Schlabach, P; Schmidt, E E; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scott, A L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Sexton-Kennedy, L; Sfyrla, A; Shapiro, M D; Shears, T; Shepard, P F; Sherman, D; Shimojima, M; Shochet, M; Shon, Y; Shreyber, I; Sidoti, A; Sinervo, P; Sisakyan, A; Sjolin, J; Slaughter, A J; Slaunwhite, J; Sliwa, K; Smith, J R; Snider, F D; Snihur, R; Soderberg, M; Soha, A; Somalwar, S; Sorin, V; Spalding, J; Spinella, F; Spreitzer, T; Squillacioti, P; Stanitzki, M; Staveris-Polykalas, A; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Stuart, D; Suh, J S; Sukhanov, A; Sun, H; Suzuki, T; Taffard, A; Takashima, R; Takeuchi, Y; Takikawa, K; Tanaka, M; Tanaka, R; Tecchio, M; Teng, P K; Terashi, K; Thom, J; Thompson, A S; Thomson, E; Tipton, P; Tiwari, V; Tkaczyk, S; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Tourneur, S; Trischuk, W; Tseng, J; Tsuchiya, R; Tsuno, S; Turini, N; Ukegawa, F; Unverhau, T; Uozumi, S; Usynin, D; Vallecorsa, S; van Remortel, N; Varganov, A; Vataga, E; Vázquez, F; Velev, G; Veramendi, G; Veszpremi, V; Vidal, R; Vila, I; Vilar, R; Vine, T; Vollrath, I; Volobouev, I; Volpi, G; Würthwein, F; Wagner, P; Wagner, R G; Wagner, R L; Wagner, J; Wagner, W; Wallny, R; Wang, S M; Warburton, A; Waschke, S; Waters, D; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Williams, G; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Wright, T; Wu, X; Wynne, S M; Yagil, A; Yamamoto, K; Yamaoka, J; Yamashita, T; Yang, C; Yang, U K; Yang, Y C; Yao, W M; Yeh, G P; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanello, L; Zanetti, A; Zaw, I; Zhang, X; Zhou, J; Zucchelli, S

    2007-03-23

    We present the first observation of the baryon decay Lambda b0-->Lambda c+pi- followed by Lambda c+-->pK-pi+ in 106 pb-1 pp collisions at square root s=1.96 TeV in the CDF experiment. In order to reduce systematic error, the measured rate for Lambda b0 decay is normalized to the kinematically similar meson decay B0-->D+pi- followed by D+-->pi+K-pi+. We report the ratio of production cross sections (sigma) times the ratio of branching fractions (B) for the momentum region integrated above pT>6 GeV/c and pseudorapidity range |eta|<1.3: sigma(pp-->Lambda b0X)/sigma(pp-->B0X)xB(Lambda b0-->Lambda c+pi-)/B(B0-->D+pi-)=0.82+/-0.08(stat)+/-0.11(syst)+/-0.22[B(Lambda c+-->pK-pi+)].

  16. Stable carbon isotope fractionation during the biodegradation of lambda-cyhalothrin.

    PubMed

    Shen, Xiaoli; Xu, Zemin; Zhang, Xichang; Yang, Fangxing

    2015-11-01

    In this study, the microbial degradation of lambda-cyhalothrin in soil was investigated using compound-specific stable isotope analysis. The results revealed that lambda-cyhalothrin was biodegraded in soil under laboratory conditions. The half-lives of lambda-cyhalothrin were determined to be 49 and 161 days in non-sterile and sterile soils spiked with 2mg/kg lambda-cyhalothrin and 84 and 154 days in non-sterile and sterile soils spiked with 10mg/kg lambda-cyhalothrin, respectively. The biodegradation of lambda-cyhalothrin resulted in carbon isotope fractionation, which shifted from -29.0‰ to -26.5‰ in soil spiked with 2mg/kg lambda-cyhalothrin, and to -27.5‰ with 10mg/kg lambda-cyhalothrin. A relationship was established between the stable carbon isotope fraction and the residual concentrations of lambda-cyhalothrin by the Rayleigh equation in which the carbon isotope enrichment factor ε of the microbial degradation of lambda-cyhalothrin in the soil was calculated as -2.53‰. This study provides an approach to quantitatively evaluate the biodegradation of lambda-cyhalothrin in soil in field studies. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Synthesis and characterization of novel pyrene-dendronized porphyrins exhibiting efficient fluorescence resonance energy transfer: optical and photophysical properties.

    PubMed

    Zaragoza-Galán, Gerardo; Fowler, Michael A; Duhamel, Jean; Rein, Regis; Solladié, Nathalie; Rivera, Ernesto

    2012-07-31

    A novel series of pyrene dendronized porphyrins bearing two and four pyrenyl groups (Py(2)-TMEG1 and Py(4)-TMEG2) were successfully synthesized. First and second generation Fréchet type dendrons (Py(2)-G1OH and Py(4)-G2OH) were prepared from 1-pyrenylbutanol and 3,5-dihydroxybenzyl alcohol. These compounds were further linked to a trimesitylphenylporphyrin containing a butyric acid spacer via an esterification reaction to obtain the desired products. Dendrons and dendronized porphyrins were fully characterized by FTIR and (1)H NMR spectroscopy and their molecular weights were determined by matrix-assisted laser desorption ionization time of flight mass spectrometry. Their optical and photophysical properties were studied by absorption and fluorescence spectroscopies. The formation of dynamic excimers was detected in the pyrene-labeled dendrons, with more excimer being produced in the higher generation dendron. The fluorescence spectra of the pyrene dendronized porphyrins exhibited a significant decrease in the amount of pyrene monomer and excimer emission, jointly with the appearance of a new emission band at 661 nm characteristic of porphyrin emission, an indication that fluorescence resonance energy transfer (FRET) occurred from one of the excited pyrene species to the porphyrin. The FRET efficiency was found to be almost quantitative ranging between 97% and 99% depending on the construct. Model Free analysis of the fluorescence decays acquired with the pyrene monomer, excimer, and porphyrin core established that only residual pyrene excimer formation in the dendrons could occur before FRET from the excited pyrene monomer to the ground-state porphyrin core.

  18. Deep Laser-Assisted Lamellar Anterior Keratoplasty with Microkeratome-Cut Grafts

    PubMed Central

    Yokogawa, Hideaki; Tang, Maolong; Li, Yan; Liu, Liang; Chamberlain, Winston; Huang, David

    2016-01-01

    Background The goals of this laboratory study were to evaluate the interface quality in laser-assisted lamellar anterior keratoplasty (LALAK) with microkeratome-cut grafts, and to achieve good graft–host apposition. Methods Simulated LALAK surgeries were performed on six pairs of eye bank corneoscleral discs. Anterior lamellar grafts were precut with microkeratomes. Deep femtosecond (FS) laser cuts were performed on host corneas followed by excimer laser smoothing. Different parameters of FS laser cuts and excimer laser smoothing were tested. OCT was used to measure corneal pachymetry and evaluate graft-host apposition. The interface quality was quantified in a masked fashion using a 5-point scale based on scanning electron microscopy images. Results Deep FS laser cuts at 226–380 μm resulted in visible ridges on the host bed. Excimer laser smoothing with central ablation depth of 29 μm and saline as a smoothing agent did not adequately reduce ridges (score = 4.0). Deeper excimer laser ablation of 58 μm and Optisol-GS as a smoothing agent smoothed ridges to an acceptable level (score = 2.1). Same sizing of the graft and host cut diameters with an approximately 50 μm deeper host side-cut relative to the central graft thickness provided the best graft–host fit. Conclusions Deep excimer laser ablation with a viscous smoothing agent was needed to remove ridges after deep FS lamellar cuts. The host side cut should be deep enough to accommodate thicker graft peripheral thickness compared to the center. This LALAK design provides smooth lamellar interfaces, moderately thick grafts, and good graft-host fits. PMID:26890667

  19. Dynamics of a family of transcendental meromorphic functions having rational Schwarzian derivative

    NASA Astrophysics Data System (ADS)

    Sajid, M.; Kapoor, G. P.

    2007-02-01

    In the present paper, a class of critically finite transcendental meromorphic functions having rational Schwarzian derivative is introduced and the dynamics of functions in one parameter family is investigated. It is found that there exist two parameter values [lambda]*=[phi](0)>0 and , where and is the real root of [phi]'(x)=0, such that the Fatou sets of f[lambda](z) for [lambda]=[lambda]* and [lambda]=[lambda]** contain parabolic domains. A computationally useful characterization of the Julia set of the function f[lambda](z) as the complement of the basin of attraction of an attracting real fixed point of f[lambda](z) is established and applied for the generation of the images of the Julia sets of f[lambda](z). Further, it is observed that the Julia set of explodes to whole complex plane for [lambda]>[lambda]**. Finally, our results found in the present paper are compared with the recent results on dynamics of one parameter families [lambda]tanz, [R.L. Devaney, L. Keen, Dynamics of meromorphic maps: Maps with polynomial Schwarzian derivative, Ann. Sci. Ecole Norm. Sup. 22 (4) (1989) 55-79; L. Keen, J. Kotus, Dynamics of the family [lambda]tan(z), Conform. Geom. Dynam. 1 (1997) 28-57; G.M. Stallard, The Hausdorff dimension of Julia sets of meromorphic functions, J. London Math. Soc. 49 (1994) 281-295] and , [lambda]>0 [G.P. Kapoor, M. Guru Prem Prasad, Dynamics of : The Julia set and bifurcation, Ergodic Theory Dynam. Systems 18 (1998) 1363-1383].

  20. Vacuum barrier for excimer lasers

    DOEpatents

    Shurter, R.P.

    1992-09-15

    A barrier for separating the vacuum area of a diode from the pressurized gas area of an excimer laser. The barrier is a composite material comprising layers of a metal such as copper, along with layers of polyimide, and a matrix of graphite fiber yarns impregnated with epoxy. The barrier is stronger than conventional foil barriers, and allows greater electron throughput. 3 figs.

  1. Time-resolved spectroscopy of solid poly/1-vinyl naphthalene/ following electron beam pulse radiolysis - Pulse radiolytic studies on polymers

    NASA Technical Reports Server (NTRS)

    Coulter, D. R.; Liang, R. H.; Di Stefano, S.; Moacanin, J.; Gupta, A.

    1982-01-01

    Transient emission studies following pulse radiolysis of solid poly(1-vinyl naphthalene) show existence of excited monomers and two excimers. Quenching experiments indicate that excimers are not formed directly by recombination of ions but probably by trapping of migrating monomeric excitation in preformed traps whose density is approximately one in 1000.

  2. 308-nm excimer laser for the treatment of alopecia areata in children.

    PubMed

    Al-Mutairi, Nawaf

    2009-01-01

    Alopecia areata (AA) is a common skin disease which is characterized by nonscarring localized or diffused hair loss. In this study we assessed the efficacy of 308-nm Excimer laser in the treatment of alopecia areata in children. A total of 9 children with 30 recalcitrant patches alopecia areata and two children with alopecia areata totalis were enrolled in this study which included seven male and four female patients, aged between 4 and 14 years and the durations of their disease were between 7 and 25 months. All of these patients had more than one lesion of alopecia areata and at least one of them was left as a control for comparison. The lesions were treated with the 308-nm Excimer laser twice a week for a period of 12 weeks. Regrowth of hair was observed in 18 (60%) alopecia patches in the scalp, while there was no response in the control patches and over the extremities. Only four patients with scalp lesions showed a recurrence of alopecia after 6 months post laser therapy. So, 308-nm Excimer laser is considered an effective safe therapeutic option for patchy alopecia areata in children.

  3. An experimental study on laser drilling and cutting of composite materials for the aerospace industry using excimer and CO2 sources

    NASA Astrophysics Data System (ADS)

    dell'Erba, M.; Galantucci, L. M.; Miglietta, S.

    This paper reports on the results of research which investigated the potential for the application of an excimer laser in the field of composite material drilling and cutting, by comparing this technology with that using CO2 sources. In particular, the scope of the work was to check whether the interaction between excimer lasers and composite materials, whose characteristic feature is the absence of thermal transfer, could yield better results than those obtainable with CO2 sources once heat transfer-induced difficulties had been eliminated. The materials selected for the experiments were multilayer composites having an epoxy resin matrix (65 percent in volume), with aramid fiber (Kevlar), carbon fiber and glass fiber as reinforcing materials, all of considerable interest for the aerospace industry. Optimal operational parameters were identified in relation to each source with a view to obtaining undersize holes or through cuts exhibiting severed areas of good quality. A comparison between the two types of processing carried out show that rims processed by excimer lasers are of better quality - particularly so with Kevlar - whereas the ablation rate is undoubtedly rather low compared with the CO2 technology.

  4. Impacts of excimer laser annealing on Ge epilayer on Si

    NASA Astrophysics Data System (ADS)

    Huang, Zhiwei; Mao, Yichen; Yi, Xiaohui; Lin, Guangyang; Li, Cheng; Chen, Songyan; Huang, Wei; Wang, Jianyuan

    2017-02-01

    The impacts of excimer laser annealing on the crystallinity of Ge epilayers on Si substrate grown by low- and high-temperature two-step approach in an ultra-high vacuum chemical vapor deposition system were investigated. The samples were treated by excimer laser annealing (ELA) at various laser power densities with the temperature above the melting point of Ge, while below that of Si, resulting in effective reduction of point defects and dislocations in the Ge layer with smooth surface. The full-width at half-maximum (FWHM) of X-ray diffraction patterns of the low-temperature Ge epilayer decreases with the increase in laser power density, indicating the crystalline improvement and negligible effect of Ge-Si intermixing during ELA processes. The short laser pulse time and large cooling rate cause quick melting and recrystallization of Ge epilayer on Si in the non-thermal equilibrium process, rendering tensile strain in Ge epilayer as calculated quantitatively with thermal mismatch between Si and Ge. The FWHM of X-ray diffraction patterns is significantly reduced for the two-step grown samples after treated by a combination of ELA and conventional furnace thermal annealing, indicating that the crystalline of Ge epilayer is improved more effectively with pre- annealing by excimer laser.

  5. Jovian Chromophore Characteristics from Multispectral HST Images

    NASA Technical Reports Server (NTRS)

    Strycker, Paul D.; Chanover, Nancy J.; Simon-Miller, Amy A.; Banfield, Don; Gierasch, Peter J.

    2011-01-01

    The chromophores responsible for coloring the jovian atmosphere are embedded within Jupiter's vertical aerosol structure. Sunlight propagates through this vertical distribution of aerosol particles, whose colors are defined by omega-bar (sub 0)(lambda), and we remotely observe the culmination of the radiative transfer as I/F(lambda). In this study, we employed a radiative transfer code to retrieve omega-bar (sub 0)(lambda) for particles in Jupiter's tropospheric haze at seven wavelengths in the near-UV and visible regimes. The data consisted of images of the 2008 passage of Oval BA to the south of the Great Red Spot obtained by the Wide Field Planetary Camera 2 on-board the Hubble Space Telescope. We present derived particle colors for locations that were selected from 14 weather regions, which spanned a large range of observed colors. All omega-bar (sub 0)(lambda) curves were absorbing in the blue, and omega-bar (sub 0)(lambda) increased monotonically to approximately unity as wavelength increased. We found accurate fits to all omega-bar (sub 0)(lambda) curves using an empirically derived functional form: omega-bar (sub 0)(lambda) = 1 A exp(-B lambda). The best-fit parameters for the mean omega-bar (sub 0)(lambda) curve were A = 25.4 and B = 0.0149 for lambda in units of nm. We performed a principal component analysis (PCA) on our omega-bar (sub 0)(lambda) results and found that one or two independent chromophores were sufficient to produce the variations in omega-bar (sub 0)(lambda). A PCA of I/F(lambda) for the same jovian locations resulted in principal components (PCs) with roughly the same variances as the omega-bar (sub 0)(lambda) PCA, but they did not result in a one-to-one mapping of PC amplitudes between the omega-bar (sub 0)(lambda) PCA and I/F(lambda) PCA. We suggest that statistical analyses performed on I/ F(lambda) image cubes have limited applicability to the characterization of chromophores in the jovian atmosphere due to the sensitivity of 1/ F(lambda) to horizontal variations in the vertical aerosol distribution.

  6. Mechanisms of Hyperbilirubinemia During Peginterferon Lambda-1a Therapy for Chronic Hepatitis C Infection: A Retrospective Investigation.

    PubMed

    Zwirtes, Ricardo; Narasimhan, Premkumar; Wind-Rotolo, Megan M; Xu, Dong; Hruska, Matthew W; Kishnani, Narendra; Colston, Elizabeth M; Srinivasan, Subasree

    2016-11-01

    The phase 2b EMERGE study compared the efficacy/safety of peginterferon lambda-1a (Lambda) and peginterferon alfa-2a (Alfa), both with ribavirin (RBV), for treatment of chronic hepatitis C virus (HCV) infection. A key safety finding was a higher frequency of hyperbilirubinemia with Lambda/RBV versus Alfa/RBV. To characterize mechanisms of hyperbilirubinemia associated with Lambda/RBV, we conducted a retrospective analysis of safety data from the HCV genotype 1 and genotype 4 cohort of the EMERGE study. Subjects were randomized to once-weekly Lambda (120/180/240 μg) or Alfa (180 μg), with daily RBV, for 48 weeks. Early-onset Lambda/RBV-related hyperbilirubinemia events (6-12 weeks) resulted mostly from RBV-induced hemolysis evidenced by sustained reticulocytosis and a predominantly unconjugated pattern of hyperbilirubinemia. The higher hyperbilirubinemia frequency with Lambda/RBV versus Alfa/RBV was attributed to bone marrow suppression known to occur with Alfa but not Lambda. Late-onset (>12 weeks) Lambda/RBV-related hyperbilirubinemia events occurred most frequently with higher Lambda doses and were associated with increased levels of hepatic transaminase and direct bilirubin fractions compared with early events. This dual pattern of hyperbilirubinemia observed while on Lambda/RBV treatment is thought to be caused by exaggerated RBV-induced hemolysis in early-onset events compared with possible direct Lambda-induced hepatocellular toxicity in late-onset events.

  7. Rearrangement and expression of the human {Psi}C{lambda}6 gene segment results in a surface Ig receptor with a truncated light chain constant region

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stiernholm, N.B.J.; Verkoczy, L.K.; Berinstein, N.L.

    1995-05-01

    The constant region of the human Ig{lambda} locus consists of seven tandemly organized J-C gene segments. Although it has been established that the J-C{lambda}1, J-C{lambda}2, J-C{lambda}3, and J-C{lambda}7 gene segments are functional, and code for the four distinct Ig{lambda} isotypes found in human serum, the J-C{lambda}4, J-C{lambda}5, and J-C{lambda}6 gene segments are generally considered to be pseudogenes. Although one example of a functional J-C{lambda}6 gene segment has been documented, in the majority of cases, J-C{lambda}6 is rendered nonfunctional by virtue of a single duplication of four nucleotides, creating a premature translational arrest. We show here that rearrangements to the J-C{lambda}6more » gene segment do occur, and that such a rearrangement encodes an Ig{lambda} protein that lacks the terminal end of the constant region. We also show that this truncated protein is expressed on the surface with the IgH chain, creating an unusual surface Ig (sIg) receptor (sIg{triangle}CL). Cells that express this receptor on the surface do so at significantly reduced levels compared with clonally related variants, which express sIg receptors with conventional Ig{lambda} L chains. However, the effects of sIg cross-linking on tyrosine phosphorylation and surface expression of the CD25 and CD71 Ags are similar in cells that express conventional sIg receptors and in those that express sIg{triangle}CL receptors, suggesting that the latter could possibly function as an Ag receptor. 35 refs., 7 figs.« less

  8. X-ray photoelectron spectroscopy study of excimer laser treated alumina films

    NASA Astrophysics Data System (ADS)

    Georgiev, D. G.; Kolev, K.; Laude, L. D.; Mednikarov, B.; Starbov, N.

    1998-01-01

    Amorphous alumina layers are deposited on a single crystal Si substrate by a e-gun evaporation technique. These films are then thermally annealed in oxygen to be crystallized and, further, irradiated with an excimer laser beam. At each stage of the film preparation, an x-ray photoelectron spectroscopy analysis is performed at the film surface and in depth, upon ion beam grinding. Results give evidence for the formation of an aluminosilicate upon thermal annealing of the film in oxygen. At the surface itself, this compound is observed to decompose upon excimer laser irradiation at energy densities exceeding 1.75 J/cm2, giving rise to free Si atoms and SiO2, however with complete disappearance of Al atoms. Model photochemical reactions are proposed to explain such transformations.

  9. Velocity measurement in rocket exhaust and general aerodynamic flows by photolysis of H2O and laser induced fluorescence of OH

    NASA Technical Reports Server (NTRS)

    Boedeker, Laurence R.

    1992-01-01

    A 'tagging' approach in which the photolysis of H2O by an excimer laser creates a zone of enhanced OH concentration, while a second, pulsed-UV laser detects tagged-zone convection via time-delayed excitation of OH fluorescence, depends on the photodissociation process and the kinetics of OH decay (relative to velocity). For application to the fuel-rich, high supersonic Mach number exhaust flow of the SSME, the detection of OH is being accomplished with either a pulsed narrowband UV dye laser or a tunable XeCl excimer laser for excitation of an OH 0-0 band transition, while the two-photon photolysis of H2O is conducted by focusing an injection-locked KrF excimer laser into the flow.

  10. Existence and non-uniqueness of similarity solutions of a boundary-layer problem

    NASA Technical Reports Server (NTRS)

    Hussaini, M. Y.; Lakin, W. D.

    1986-01-01

    A Blasius boundary value problem with inhomogeneous lower boundary conditions f(0) = 0 and f'(0) = - lambda with lambda strictly positive was considered. The Crocco variable formulation of this problem has a key term which changes sign in the interval of interest. It is shown that solutions of the boundary value problem do not exist for values of lambda larger than a positive critical value lambda. The existence of solutions is proven for 0 lambda lambda by considering an equivalent initial value problem. It is found however that for 0 lambda lambda, solutions of the boundary value problem are nonunique. Physically, this nonuniqueness is related to multiple values of the skin friction.

  11. Existence and non-uniqueness of similarity solutions of a boundary layer problem

    NASA Technical Reports Server (NTRS)

    Hussaini, M. Y.; Lakin, W. D.

    1984-01-01

    A Blasius boundary value problem with inhomogeneous lower boundary conditions f(0) = 0 and f'(0) = - lambda with lambda strictly positive was considered. The Crocco variable formulation of this problem has a key term which changes sign in the interval of interest. It is shown that solutions of the boundary value problem do not exist for values of lambda larger than a positive critical value lambda. The existence of solutions is proven for 0 lambda lambda by considering an equivalent initial value problem. It is found however that for 0 lambda lambda, solutions of the boundary value problem are nonunique. Physically, this nonuniqueness is related to multiple values of the skin friction.

  12. Measurement of the Lambda b0 lifetime in Lambda b0-->J/psi Lambda 0 in pp collisions at square root s=1.96 TeV.

    PubMed

    Abulencia, A; Adelman, J; Affolder, T; Akimoto, T; Albrow, M G; Ambrose, D; Amerio, S; Amidei, D; Anastassov, A; Anikeev, K; Annovi, A; Antos, J; Aoki, M; Apollinari, G; Arguin, J-F; Arisawa, T; Artikov, A; Ashmanskas, W; Attal, A; Azfar, F; Azzi-Bacchetta, P; Azzurri, P; Bacchetta, N; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Baroiant, S; Bartsch, V; Bauer, G; Bedeschi, F; Behari, S; Belforte, S; Bellettini, G; Bellinger, J; Belloni, A; Benjamin, D; Beretvas, A; Beringer, J; Berry, T; Bhatti, A; Binkley, M; Bisello, D; Blair, R E; Blocker, C; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bolla, G; Bolshov, A; Bortoletto, D; Boudreau, J; Boveia, A; Brau, B; Brigliadori, L; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Budroni, S; Burkett, K; Busetto, G; Bussey, P; Byrum, K L; Cabrera, S; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carrillo, S; Carlsmith, D; Carosi, R; Carron, S; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, I; Cho, K; Chokheli, D; Chou, J P; Choudalakis, G; Chuang, S H; Chung, K; Chung, W H; Chung, Y S; Ciljak, M; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Coca, M; Compostella, G; Convery, M E; Conway, J; Cooper, B; Copic, K; Cordelli, M; Cortiana, G; Crescioli, F; Cuenca Almenar, C; Cuevas, J; Culbertson, R; Cully, J C; Cyr, D; DaRonco, S; D'Auria, S; Davies, T; D'Onofrio, M; Dagenhart, D; de Barbaro, P; De Cecco, S; Deisher, A; De Lentdecker, G; Dell'Orso, M; Delli Paoli, F; Demortier, L; Deng, J; Deninno, M; De Pedis, D; Derwent, P F; Di Giovanni, G P; Dionisi, C; Di Ruzza, B; Dittmann, J R; DiTuro, P; Dörr, C; Donati, S; Donega, M; Dong, P; Donini, J; Dorigo, T; Dube, S; Efron, J; Erbacher, R; Errede, D; Errede, S; Eusebi, R; Fang, H C; Farrington, S; Fedorko, I; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Field, R; Flanagan, G; Foland, A; Forrester, S; Foster, G W; Franklin, M; Freeman, J C; Furic, I; Gallinaro, M; Galyardt, J; Garcia, J E; Garberson, F; Garfinkel, A F; Gay, C; Gerberich, H; Gerdes, D; Giagu, S; Giannetti, P; Gibson, A; Gibson, K; Gimmell, J L; Ginsburg, C; Giokaris, N; Giordani, M; Giromini, P; Giunta, M; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Goldstein, J; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gresele, A; Griffiths, M; Grinstein, S; Grosso-Pilcher, C; Group, R C; Grundler, U; Guimaraes da Costa, J; Gunay-Unalan, Z; Haber, C; Hahn, K; Hahn, S R; Halkiadakis, E; Hamilton, A; Han, B-Y; Han, J Y; Handler, R; Happacher, F; Hara, K; Hare, M; Harper, S; Harr, R F; Harris, R M; Hartz, M; Hatakeyama, K; Hauser, J; Heijboer, A; Heinemann, B; Heinrich, J; Henderson, C; Herndon, M; Heuser, J; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Holloway, A; Hou, S; Houlden, M; Hsu, S-C; Huffman, B T; Hughes, R E; Husemann, U; Huston, J; Incandela, J; Introzzi, G; Iori, M; Ishizawa, Y; Ivanov, A; Iyutin, B; James, E; Jang, D; Jayatilaka, B; Jeans, D; Jensen, H; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Jung, J E; Junk, T R; Kamon, T; Karchin, P E; Kato, Y; Kemp, Y; Kephart, R; Kerzel, U; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kimura, N; Kirsch, L; Klimenko, S; Klute, M; Knuteson, B; Ko, B R; Kondo, K; Kong, D J; Konigsberg, J; Korytov, A; Kotwal, A V; Kovalev, A; Kraan, A C; Kraus, J; Kravchenko, I; Kreps, M; Kroll, J; Krumnack, N; Kruse, M; Krutelyov, V; Kubo, T; Kuhlmann, S E; Kuhr, T; Kusakabe, Y; Kwang, S; Laasanen, A T; Labarga, L; Lai, S; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; LeCompte, T; Lee, J; Lee, J; Lee, Y J; Lee, S W; Lefèvre, R; Leonardo, N; Leone, S; Levy, S; Lewis, J D; Lin, C; Lin, C S; Lindgren, M; Lipeles, E; Liss, T M; Lister, A; Litvintsev, D O; Liu, T; Lockyer, N S; Loginov, A; Loreti, M; Loverre, P; Lu, R-S; Lucchesi, D; Lujan, P; Lukens, P; Lungu, G; Lyons, L; Lys, J; Lysak, R; Lytken, E; Mack, P; MacQueen, D; Madrak, R; Maeshima, K; Makhoul, K; Maki, T; Maksimovic, P; Malde, S; Manca, G; Margaroli, F; Marginean, R; Marino, C; Marino, C P; Martin, A; Martin, M; Martin, V; Martínez, M; Maruyama, T; Mastrandrea, P; Masubuchi, T; Matsunaga, H; Mattson, M E; Mazini, R; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Menzemer, S; Menzione, A; Merkel, P; Mesropian, C; Messina, A; Miao, T; Miladinovic, N; Miles, J; Miller, R; Mills, C; Milnik, M; Mitra, A; Mitselmakher, G; Miyamoto, A; Moed, S; Moggi, N; Mohr, B; Moore, R; Morello, M; Movilla Fernandez, P; Mülmenstädt, J; Mukherjee, A; Muller, Th; Mumford, R; Murat, P; Nachtman, J; Nagano, A; Naganoma, J; Nahn, S; Nakano, I; Napier, A; Necula, V; Neu, C; Neubauer, M S; Nielsen, J; Nigmanov, T; Nodulman, L; Norniella, O; Nurse, E; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Oldeman, R; Orava, R; Osterberg, K; Pagliarone, C; Palencia, E; Papadimitriou, V; Paramonov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Piedra, J; Pinera, L; Pitts, K; Plager, C; Pondrom, L; Portell, X; Poukhov, O; Pounder, N; Prokoshin, F; Pronko, A; Proudfoot, J; Ptochos, F; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Ranjan, N; Rappoccio, S; Reisert, B; Rekovic, V; Renton, P; Rescigno, M; Richter, S; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Ruiz, A; Russ, J; Rusu, V; Saarikko, H; Sabik, S; Safonov, A; Sakumoto, W K; Salamanna, G; Saltó, O; Saltzberg, D; Sánchez, C; Santi, L; Sarkar, S; Sartori, L; Sato, K; Savard, P; Savoy-Navarro, A; Scheidle, T; Schlabach, P; Schmidt, E E; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scott, A L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Sexton-Kennedy, L; Sfyrla, A; Shapiro, M D; Shears, T; Shepard, P F; Sherman, D; Shimojima, M; Shochet, M; Shon, Y; Shreyber, I; Sidoti, A; Sinervo, P; Sisakyan, A; Sjolin, J; Slaughter, A J; Slaunwhite, J; Sliwa, K; Smith, J R; Snider, F D; Snihur, R; Soderberg, M; Soha, A; Somalwar, S; Sorin, V; Spalding, J; Spinella, F; Spreitzer, T; Squillacioti, P; Stanitzki, M; Staveris-Polykalas, A; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Stuart, D; Suh, J S; Sukhanov, A; Sun, H; Suzuki, T; Taffard, A; Takashima, R; Takeuchi, Y; Takikawa, K; Tanaka, M; Tanaka, R; Tecchio, M; Teng, P K; Terashi, K; Tesarek, R J; Thom, J; Thompson, A S; Thomson, E; Tipton, P; Tiwari, V; Tkaczyk, S; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Tourneur, S; Trischuk, W; Tsuchiya, R; Tsuno, S; Turini, N; Ukegawa, F; Unverhau, T; Uozumi, S; Usynin, D; Vallecorsa, S; van Remortel, N; Varganov, A; Vataga, E; Vázquez, F; Velev, G; Veramendi, G; Veszpremi, V; Vidal, R; Vila, I; Vilar, R; Vine, T; Vollrath, I; Volobouev, I; Volpi, G; Würthwein, F; Wagner, P; Wagner, R G; Wagner, R L; Wagner, J; Wagner, W; Wallny, R; Wang, S M; Warburton, A; Waschke, S; Waters, D; Weinberger, M; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Williams, G; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Wright, T; Wu, X; Wynne, S M; Yagil, A; Yamamoto, K; Yamaoka, J; Yamashita, T; Yang, C; Yang, U K; Yang, Y C; Yao, W M; Yeh, G P; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanello, L; Zanetti, A; Zaw, I; Zhang, X; Zhou, J; Zucchelli, S

    2007-03-23

    We report a measurement of the Lambda b0 lifetime in the exclusive decay Lambda b0-->J/psi Lambda 0 in pp collisions at square root s=1.96 TeV using an integrated luminosity of 1.0 fb-1 of data collected by the CDF II detector at the Fermilab Tevatron. Using fully reconstructed decays, we measure tau(Lambda b0)=1.593(-0.078)(+0.083)(stat)+/-0.033(syst) ps. This is the single most precise measurement of tau(Lambda b0) and is 3.2sigma higher than the current world average.

  13. Observation of the baryonic B decay B{sup 0}{yields}{Lambda}{sub c}{sup +}{Lambda}K{sup -}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lees, J. P.; Poireau, V.; Tisserand, V.

    2011-10-01

    We report the observation of the baryonic B decay B{sup 0}{yields}{Lambda}{sub c}{sup +}{Lambda}K{sup -} with a significance larger than 7 standard deviations based on 471x10{sup 6} BB pairs collected with the BABAR detector at the PEP-II storage ring at SLAC. We measure the branching fraction for the decay B{sup 0}{yields}{Lambda}{sub c}{sup +}{Lambda}K{sup -} to be (3.8{+-}0.8{sub stat}{+-}0.2{sub sys}{+-}1.0{sub {Lambda}}{sub c}{sup +})x10{sup -5}. The uncertainties are statistical, systematic, and due to the uncertainty in the {Lambda}{sub c}{sup +} branching fraction. We find that the {Lambda}{sub c}{sup +}K{sup -} invariant-mass distribution shows an enhancement above 3.5 GeV/c{sup 2}.

  14. Avoiding pitfalls in the determination of halocarboxylic acids: the photochemistry of methylation.

    PubMed

    Rubio, F J; Urbansky, E T; Magnuson, M L

    2000-06-01

    Haloethanoic (haloacetic) acids are formed during chlorination of drinking water and are regulated by the Environmental Protection Agency (EPA). These compounds are normally quantified by gas chromatography with electron capture detection (GC-ECD) as the methyl esters. EPA Method 552 uses diazomethane (CH2N2) for this purpose, but has only been validated by EPA for HAA6: chloro-, dichloro-, bromo-, dibromo-, bromochloro- and trichloroacetic acids. EPA Method 552.2 was developed and validated for all nine analytes (HAA9 = HAA6 + dibromochloro-, bromodichloro- and tribromoethanoic acids). Since the promulgation of Method 552.2, which uses acidic methanol, a debate has ensued over discrepancies observed by various laboratories when using diazomethane instead. In an effort to identify and eliminate potential sources for these discrepancies, a comparative study was undertaken for HAA9. Better accuracy and precision were observed for all HAA9 species by Method 552.2; recoveries were satisfactory in de-ionized and tap water. Method 552 remains satisfactory for HAA6. Systematic differences in instrumental response are observed for the two methods, but these are precise and may be accounted for using similarly treated standards and analyte-fortified (spiked) samples. That notwithstanding, Method 552 (CH2N2) was shown to be unsuitable for dibromochloro-, bromodichloro- and tribromoethanoic acids (HAA9-6). The primary problem appears to be a photoactivated reaction between diazomethane and the HAA9-6 analytes; however, side reactions were found to occur even in the dark. Analyte loss is most pronounced under typical laboratory lighting (white F40 fluorescent lamps + sunlight), but it is also observed under Philips gold F40 lamps (lambda > or = 520 nm), and in the dark.

  15. Doublet-spacing enhancement caused by {Lambda}N-{Sigma}N coupling in {sub {Lambda}L}i hypernuclear isotopes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Umeya, Atsushi; Harada, Toru; Research Center for Physics and Mathematics, Osaka Electro-Communication University, Neyagawa, Osaka 572-8530

    2011-03-15

    We theoretically investigate energy spacings of doublets in {sub {Lambda}L}i hypernuclear isotopes with A=7-10 in shell-model calculations with a {Lambda}N-{Sigma}N coupling effect. The calculated results show that the energy shifts are {Delta}{epsilon}=0.09-0.28 MeV and the {Sigma}-mixing probabilities are P{sub {Sigma}}=0.10%-0.34% in {Lambda} ground states for the isotopes because of the {Lambda}N-{Sigma}N coupling in the first-order perturbation. It is found that the energy spacing of the doublet is enhanced as a neutron number N increases; the contribution of the {Lambda}N-{Sigma}N coupling interaction is comparable to that of the {Lambda}N interaction in the neutron-rich {Lambda} hypernuclei. The coherent mechanism of this doublet-spacingmore » enhancement is also discussed in terms of Fermi-type and Gamow-Teller-type {Lambda}N-{Sigma}N couplings.« less

  16. The role of template superhelicity in the initiation of bacteriophage lambda DNA replication.

    PubMed Central

    Alfano, C; McMacken, R

    1988-01-01

    The prepriming steps in the initiation of bacteriophage lambda DNA replication depend on the action of the lambda O and P proteins and on the DnaB helicase, single-stranded DNA binding protein (SSB), and DnaJ and DnaK heat shock proteins of the E. coli host. The binding of multiple copies of the lambda O protein to the phage replication origin (ori lambda) initiates the ordered assembly of a series of nucleoprotein structures that form at ori lambda prior to DNA unwinding, priming and DNA synthesis steps. Since the initiation of lambda DNA replication is known to occur only on supercoiled templates in vivo and in vitro, we examined how the early steps in lambda DNA replication are influenced by superhelical tension. All initiation complexes formed prior to helicase-mediated DNA-unwinding form with high efficiency on relaxed ori lambda DNA. Nonetheless, the DNA templates in these structures must be negatively supertwisted before they can be replicated. Once DNA helicase unwinding is initiated at ori lambda, however, later steps in lambda DNA replication proceed efficiently in the absence of superhelical tension. We conclude that supercoiling is required during the initiation of lambda DNA replication to facilitate entry of a DNA helicase, presumably the DnaB protein, between the DNA strands. Images PMID:2847118

  17. Galaxy formation in Lambda greater than 0 Friedmann models: Consequences for the number counts versus redshift test

    NASA Technical Reports Server (NTRS)

    Martel, Hugo

    1994-01-01

    We study the effect of the cosmological constant Lambda on galaxy formation using a simple spherical top-hat overdensity model. We consider models with Omega(sub 0) = 0.2, lambda(sub 0) = 0, and Omega(sub 0) = 0.2, lambda(sub 0) = 0.8 (where Omega(sub 0) is the density parameter, and lambda(sub 0) identically equal Lambda/3 H(sub 0 exp 2) where H(sub 0) is the Hubble constant). We adjust the initial power spectrum amplitude so that both models reproduce the same large-scale structures. The galaxy formation era in the lambda(sub 0) = 0 model occurs early (z approximately 6) and is very short, whereas in the lambda(sub 0) = 0.8 model the galaxy formation era starts later (z approximately 4), and last much longer, possibly all the way to the present. Consequently, galaxies at low redshift (z less than 1) are significantly more evolved in the lambda(sub 0) = 0 model than in the lambda(sub 0) = 0.8 model. This result implies that previous attempts to determine Lambda using the number counts versus redshift test are probably unreliable.

  18. Photochemical and Spectroscopic Effects Resulting from Excimer Laser Excitation.

    NASA Astrophysics Data System (ADS)

    Wang, Xuan Xiao

    I. Photochemical production of ozone from pure oxygen using excimer lasers. Production of ozone was observed from experiments when oxygen was under a broadband pulsed KrF laser radiation. The production process was found to be autocatalytic. Mechanisms for the ozone formation were proposed. Experimental results over a range of oxygen pressure and laser pulse energy (irradiance) provided evidences in favor of the proposed mechanisms. Experiments were also numerically modeled. Good agreement between the experimental and the numerical results were observed, which provided further evidence to support the proposed mechanisms. Cross sections for some photochemical processes in the mechanisms were estimated. Production of ozone from pure oxygen under a ArF excimer laser radiation (193 nm) was also studied and numerically modeled. Effects of ambient water vapor on ozone production were investigated. Experimental results showed a fast ozone destruction when water vapor was present in the cell. However, numerical results obtained from the well-known OH and HO _2 chain ozone destruction mechanism predicted a slower ozone destruction. Possible reasons for the discrepancy are discussed. II. Resonance-enhanced multiphoton ionization of N_2 at 193 and 248 nm detected by N_sp{2}{+} fluorescence. Using a broadband excimer laser operating at 193 and 248 nm multiphoton ionization at high pressures in air and pure nitrogen has been detected by fluorescence from N_sp{2}{+} in the B-X firstnegative system. Measurements of the fluorescence intensity as a function of beam irradiance indicate resonance in N_2 at the energy of two 193 nm photons (2 + 1 REMPI) and three 248 nm photons (3 + 1 REMPI). Possible intermediate states are discussed. III. Excimer laser-induced fluorescence from some organic solvents. Fluorescence was observed from vapor phase benzene, toluene, p-xylene, benzyl chloride, methyl benzoate, acetic anhydride, ether, methanol, ethyl acetone, acetone, and 2-butanone using a broadband excimer laser operating at 248 nm and 308 nm as the source of excitation. Absolute fluorescence quantum yields for the substances under study were measured at 248 nm using toluene as the fluorescence standard. Fluorescence spectra from species produced from nonlinear photochemical processes were also studied.

  19. Development of in-vitro models to elucidate mechanisms of intrinsic cellular and tissue fluorescence

    NASA Astrophysics Data System (ADS)

    Savage, Howard E.; Kolli, Venkateswara; Saha, Sanjoy; Zhang, Jian C.; Glasgold, Mark; Sacks, Peter G.; Alfano, Robert R.; Schantz, Stimson P.

    1995-04-01

    In vitro cell model systems have been used to study the mechanisms of intrinsic cellular and tissue fluorescence as a potential biomarker for cancer. Phenotypic characteristics of cancer that are different from normal tissue include changes in histoarchitecture, proliferation rates and differentiation. a nitrosmethlybenzylamine (NMBA)/rat esophageal carcinogenesis model (NMBA), a transforming growth factor beta (TGF- (beta) )/normal epithelial cell model, and a retinoic acid (RA)/multicellular tumor spheroid model (RAMTS) were used to assess fluorescence changes associated respectively with changes in histoarchitecture, proliferation rates and differentiation. A xenon based fluorescence spectrophotometer (Mediscience Corp.) was used to collect excitation and emission spectra. Two excitation scans ((lambda) Ex 200-360 nm, (lambda) Em 380 nm; (lambda) Ex 240-430 nm, (lambda) Em 450 nm) and two emission scans ((lambda) Ex 300 nm, (lambda) Em 320-580 nm; (lambda) Ex 340 nm, (lambda) Em 360-660 nm) were used to analyze the three model systems. Using the NMBA model. Differences were seen in the excitation scan ((lambda) Ex 200-360 nm, (lambda) Em 380 nm) and the emission scan ((lambda) Ex 340 nm, (lambda) Em 360-660 nm) when normal rat esophageal tissue was compared to hyperplastic and tumor tissue. In the (TGF-(beta) ) model, differences were seen in the excitation scan ((lambda) Ex 240-430 nm, (lambda) Em 450 nm) when comparing proliferation slowed (TGF-(beta) treated) epithelial cells to their untreated controls. In the RAMTS model, differences were seen with all four scans when RA treated multicellular tumor spheroids (nondifferentiating) were compared to untreated control cells (differentiating). The data indicate that fluorescence changes seen in these model systems may relate to changes in histoarchitecture, proliferation rates and differentiation. Their relationship to in vivo fluorescence changes seen in cancer patients remains to be elucidated.

  20. First measurement of the ratio of branching fractions B({lambda}{sub b}{sup 0}{yields}{lambda}{sub c}{sup +}{mu}{sup -}{nu}{sub {mu}})/B({lambda}{sub b}{sup 0}{yields}{lambda}{sub c}{sup +}{pi}{sup -})

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aaltonen, T.; Maki, T.; Mehtala, P.

    2009-02-01

    This article presents the first measurement of the ratio of branching fractions B({lambda}{sub b}{sup 0}{yields}{lambda}{sub c}{sup +}{mu}{sup -}{nu}{sub {mu}})/B({lambda}{sub b}{sup 0}{yields}{lambda}{sub c}{sup +}{pi}{sup -}). Measurements in two control samples using the same technique B(B{sup 0}{yields}D{sup +}{mu}{sup -}{nu}{sub {mu}})/B(B{sup 0}{yields}D{sup +}{pi}{sup -}) and B(B{sup 0}{yields}D*(2010){sup +}{mu}{sup -}{nu}{sub {mu}})/B(B{sup 0}{yields}D*(2010){sup +}{pi}{sup -}) are also reported. The analysis uses data from an integrated luminosity of approximately 172 pb{sup -1} of pp collisions at {radical}(s)=1.96 TeV, collected with the CDF II detector at the Fermilab Tevatron. The relative branching fractions are measured to be (B({lambda}{sub b}{sup 0}{yields}{lambda}{sub c}{sup +}{mu}{sup -}{nu}{sub {mu}})/B({lambda}{sub b}{sup 0}{yields}{lambda}{sub c}{supmore » +}{pi}{sup -}))=16.6{+-}3.0(stat){+-}1.0(syst)(+2.6/-3.4)(PDG){+-}0.3 (EBR), (B(B{sup 0}{yields}D{sup +}{mu}{sup -}{nu}{sub {mu}})/B(B{sup 0}{yields}D{sup +}{pi}{sup -}))9.9{+-}1.0(stat){+-}0.6(syst){+-}0.4(PDG){+-}0.5(EBR), and (B(B{sup 0}{yields}D*(2010){sup +}{mu}{sup -}{nu}{sub {mu}})/B(B{sup 0}{yields}D*(2010){sup +}{pi}{sup -}))=16.5{+-}2.3(stat){+-} 0.6(syst){+-}0.5(PDG){+-}0.8(EBR). The uncertainties are from statistics (stat), internal systematics (syst), world averages of measurements published by the Particle Data Group or subsidiary measurements in this analysis (PDG), and unmeasured branching fractions estimated from theory (EBR), respectively. This article also presents measurements of the branching fractions of four new {lambda}{sub b}{sup 0} semileptonic decays: {lambda}{sub b}{sup 0}{yields}{lambda}{sub c}(2595){sup +}{mu}{sup -}{nu}{sub {mu}}, {lambda}{sub b}{sup 0}{yields}{lambda}{sub c}(2625){sup +}{mu}{sup -}{nu}{sub {mu}}, {lambda}{sub b}{sup 0}{yields}{sigma}{sub c}(2455){sup 0}{pi}{sup +}{mu}{sup -}{nu}{sub {mu}}, and {lambda}{sub b}{sup 0}{yields}{sigma}{sub c}(2455){sup ++}{pi}{sup -}{mu}{sup -}{nu}{sub {mu}}, relative to the branching fraction of the {lambda}{sub b}{sup 0}{yields}{lambda}{sub c}{sup +}{mu}{sup -}{nu}{sub {mu}} decay. Finally, the transverse-momentum distribution of {lambda}{sub b}{sup 0} baryons produced in pp collisions is measured and found to be significantly different from that of B{sup 0} mesons, which results in a modification in the production cross-section ratio {sigma}{sub {lambda}{sub b}{sup 0}}/{sigma}{sub B{sup 0}} with respect to the CDF I measurement.« less

  1. Automatic alignment of double optical paths in excimer laser amplifier

    NASA Astrophysics Data System (ADS)

    Wang, Dahui; Zhao, Xueqing; Hua, Hengqi; Zhang, Yongsheng; Hu, Yun; Yi, Aiping; Zhao, Jun

    2013-05-01

    A kind of beam automatic alignment method used for double paths amplification in the electron pumped excimer laser system is demonstrated. In this way, the beams from the amplifiers can be transferred along the designated direction and accordingly irradiate on the target with high stabilization and accuracy. However, owing to nonexistence of natural alignment references in excimer laser amplifiers, two cross-hairs structure is used to align the beams. Here, one crosshair put into the input beam is regarded as the near-field reference while the other put into output beam is regarded as the far-field reference. The two cross-hairs are transmitted onto Charge Coupled Devices (CCD) by image-relaying structures separately. The errors between intersection points of two cross-talk images and centroid coordinates of actual beam are recorded automatically and sent to closed loop feedback control mechanism. Negative feedback keeps running until preset accuracy is reached. On the basis of above-mentioned design, the alignment optical path is built and the software is compiled, whereafter the experiment of double paths automatic alignment in electron pumped excimer laser amplifier is carried through. Meanwhile, the related influencing factors and the alignment precision are analyzed. Experimental results indicate that the alignment system can achieve the aiming direction of automatic aligning beams in short time. The analysis shows that the accuracy of alignment system is 0.63μrad and the beam maximum restoration error is 13.75μm. Furthermore, the bigger distance between the two cross-hairs, the higher precision of the system is. Therefore, the automatic alignment system has been used in angular multiplexing excimer Main Oscillation Power Amplification (MOPA) system and can satisfy the requirement of beam alignment precision on the whole.

  2. Clinical results of PRK touch-up using Chiron/Technolas Keracor 116 excimer laser

    NASA Astrophysics Data System (ADS)

    Davidian, Mary E.; Keates, Richard H.; Ren, Qiushi

    1995-05-01

    Regression of effect as well as undercorrection are well established complications of excimer photorefractive keratectomy for the correction of myopia. In thirteen eyes initially treated with the VISX Taunton excimer laser and then retreated with the Chiron Technolas laser, the minimum follow-up time was six months. The mean postoperative refraction at six months was -0.442 +/- 0.996 D (diopters), significantly different from the pretreatment mean of -1.904 +/- 1.297 D. At six months after retreatment (10/13 eyes) 76.9% had an uncorrected visual acuity greater than or equal to 20/40 and (10/13 eyes) 76.9% were within 1 diopter of emmetropia. Only one eye had a significant increase in postoperative haze. The results of this study indicate that the majority of photorefractive keratectomy regressions and undercorrections can be successfully retreated.

  3. Investigation of gold and bimetallic gold/silver nanoparticles in soda-lime-silicate glasses formed by means of excimer laser irradiation

    NASA Astrophysics Data System (ADS)

    Heinz, M.; Dubiel, M.; Meinertz, J.; Ihlemann, J.; Hoell, A.

    2017-02-01

    In this study, plasmonic Au and Au/Ag nanostructures in soda-lime-silicate glasses have been generated by means of ArF-excimer laser irradiation (193 nm) below the ablation threshold of the glass. For this purpose pure and silver/sodium ion-exchanged float glasses have been coated by gold and then irradiated by the laser. The formation of Au and Au/Ag nanoparticles could be verified by the surface plasmon resonances between 420 and 620 nm, which were obtained by optical spectroscopy. Both, pure Au and Ag particles as well as bimetallic Au/Ag nanoparticles, could be observed by means of small angle X-ray scattering experiments. These results demonstrate that such procedures enable the spaceselected generation of plasmonic nanostructures in glass surfaces by excimer laser irradiation.

  4. On the nature of the nova-like variable CD-42 deg 14462

    NASA Technical Reports Server (NTRS)

    Guinan, E. F.; Sion, E. M.

    1981-01-01

    Low dispersion long and short wavelength IUE spectra of the nova like system CD-42 deg 14462 were obtained on August 24 U.T. The short wave spectrum exhibits absorption features due to C III (lambda 1175), Lalpha 1216), NV (lambda1240), HeII (lambda 1640), SiIV (lambda1394), NIV (lambda1875) with CIV (lambda1550) as a P Cygni feature with blue shifted absorption suggesting the presence of material leaving the system. Possible interpretations of this object are discussed.

  5. Anti p and anti Lambda production in Si + Au collisions at the AGS

    NASA Technical Reports Server (NTRS)

    Wu, Yue-Dong

    1996-01-01

    (anti (ital p)) and (anti (Lambda)) production in central Si + Au collisions has been measured by E589 at the BNL-AGS. Preliminary (ital m)(sub (perpendicular)) spectra are presented for (anti (ital p))'s and (anti (Lambda))'s. The (ital dn/dy) distribution for (anti (ital p))'s is also presented. Based on the (anti (ital p)) and (anti (Lambda)) measurements, (anti (Lambda))/(anti (ital p)) ratios are calculated in the rapidity range of 1.1-1.5.

  6. ASYMMETRIC ABSORPTION PROFILES OF Ly{alpha} AND Ly{beta} IN DAMPED Ly{alpha} SYSTEMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Hee-Won, E-mail: hwlee@sejong.ac.kr

    2013-08-01

    Damped Ly{alpha} systems observed in the quasar spectra are characterized by a high neutral hydrogen column density, N{sub HI} > 2 x 10{sup 20} cm{sup -2}. The absorption wing profiles are often fitted using the Voigt function due to the fact that the scattering cross section near the resonant line center is approximately described by the Lorentzian function. Since a hydrogen atom has infinitely many p states that participate in the electric dipole interaction, the cross section starts to deviate from the Lorentzian in an asymmetric way in the line wing regions. We investigate this asymmetry in the absorption linemore » profiles around Ly{alpha} and Ly{beta} as a function of the neutral hydrogen column density N{sub HI}. In terms of {Delta}{lambda} {identical_to} {lambda} - {lambda}{sub {alpha}}, we expand the Kramers-Heisenberg formula around Ly{alpha} to find {sigma}({lambda}) {approx_equal} (0.5f{sub 12}){sup 2}{sigma}{sub T}({Delta}{lambda}/{lambda}{sub {alpha}}){sup -2}[1 + 3.792({Delta}{lambda}/{lambda}{sub {alpha}})], where f{sub 12} and {sigma}{sub T} are the oscillator strength of Ly{alpha} and the Thomson scattering cross section, respectively. In terms of {Delta}{lambda}{sub 2} {identical_to} {lambda} - {lambda}{sub {beta}} in the vicinity of Ly{beta}, the total scattering cross section, given as the sum of cross sections for Rayleigh and Raman scattering, is shown to be {sigma}({lambda}) {approx_equal} {sigma}{sub T}(0.5f{sub 13}){sup 2}(1 + R{sub 0})({Delta}{lambda}{sub 2}/{lambda}{sub {beta}}){sup -2}[1 - 24.68({Delta}{lambda}{sub 2}/{lambda}{sub {beta}})] with f{sub 13} and the factor R{sub 0} = 0.1342 being the oscillator strength for Ly{beta} and the ratio of the Raman cross section to Rayleigh cross section, respectively. A redward asymmetry develops around Ly{alpha}, whereas a blue asymmetry is obtained for Ly{beta}. The absorption center shifts are found to be almost proportional to the neutral hydrogen column density.« less

  7. A review of monochromatic light devices for the treatment of alopecia areata.

    PubMed

    Darwin, Evan; Arora, Harleen; Hirt, Penelope A; Wikramanayake, Tongyu Cao; Jimenez, Joaquin J

    2018-02-01

    There are many laser technologies that are being tested that claim to support hair regrowth for patients with alopecia areata (AA). In this paper, we will determine whether the body of evidence supports the use of devices using monochromatic light sources to treat AA. Articles were gathered from PubMed, Embase, and the Cochrane database using these keywords: lasers, excimer laser, low-level laser therapy (LLLT), low-level light therapy, alopecia, alopecia areata, and hair loss with a category modifier of English. Ten clinical trials and seven case reports/abstracts were assessed. Eight clinical trials and two case reports demonstrated hair regrowth with the 308-nm excimer laser/light in men, women, and children. One case report demonstrated hair regrowth with the ALBA 355® laser. One clinical trial and two case reports demonstrated hair regrowth with LLLT. While two case reports demonstrated hair regrowth with fractional laser therapy, one clinical trial showed no improvement. The 308-nm excimer laser is a safe and effective treatment for men, women, and children with refractory AA of the scalp and beard. Larger, double-blinded clinical trials should be conducted to compare excimer laser therapy to standard treatments. More data is needed to determine the efficacy of LLLT and fractional laser therapy in the treatment of AA.

  8. Excimer Laser Versus Phakic Intraocular Lenses for Myopia and Astigmatism: A Meta-Analysis of Randomized Controlled Trials.

    PubMed

    Chen, Haiting; Liu, Yu; Niu, Guangzeng; Ma, Jingxue

    2018-05-01

    Meta-analysis of randomized controlled trials (RCTs) which compared excimer laser refractive surgery and phakic intraocular lenses (PIOLs) for the treatment of myopia and astigmatism. An electronic literature search was performed using the PubMed, EBSCO, CNKI, and Cochrane Library database to identify prospective RCTs which compared excimer laser refractive surgery and PIOL with a follow-up time of at least 12 months. Efficacy, accuracy, safety outcomes, and complications were analyzed by standardized mean difference, risk ratio, and the pooled estimates according to a fixed effect model or random effect model. This review included 5 RCTs with a sum of 405 eyes. The range of myopia was 6.0 to 20.0 D with up to 4.0 D of astigmatism. The PIOL group was more likely to achieve a spherical equivalence within±1.0 D of target refraction at 12 months postoperatively (P=0.009), and was less likely to lose one or more lines of best spectacle corrected visual acuity than the LASER group (P=0.002). On the whole, there is no significant difference in efficacy and complications between the two kinds of surgeries. This meta-analysis indicated that PIOLs were safer and more accurate within 12 months of follow-up compared with excimer laser surgical for refractive errors.

  9. Report on the Study of Radiation Damage in Calcium Fluoride and Magnesium Fluoride Crystals for use in Excimer Laser Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    1999-10-04

    A study was performed to investigate the effects of radiation damage in calcium fluoride and magnesium fluoride crystals caused by gamma rays and UV photons from excimer lasers. The purpose was to study and correlate the damage caused by these two different mechanisms in various types of material used for fabricating optical elements in high power excimer lasers and lens systems of lithography tools. These optical systems are easily damaged by the laser itself, and it is necessary to use only the most radiation resistant materials for certain key elements. It was found that a clear correlation exists between the,more » radiation induced damage caused by high energy gamma rays and that produced by UV photons from the excimer laser. This correlation allows a simple procedure to be developed to select the most radiation resistant material at the ingot level, which would be later used to fabricate various components of the optical system. This avoids incurring the additional cost of fabricating actual optical elements with material that would later be damaged under prolonged use. The result of this screening procedure can result in a considerable savings in the overall cost of the lens and laser system.« less

  10. Effective treatment of etanercept and phototherapy-resistant psoriasis using the excimer laser.

    PubMed

    Park, Kelly K; Swan, James; Koo, John

    2012-03-15

    Treatment of moderate-to-severe plaque psoriasis often requires the use of phototherapy or systemic therapy, which includes immunosuppressants, retinoids, and biologic agents. Although biologic use is becoming increasingly popular, it is not uncommon for patients to experience treatment failure. We describe a patient who had a suboptimal response to etanercept monotherapy after twelve weeks of induction dosing (50 mg twice weekly), as well as to a combination of etanercept (50 mg once weekly-maintenance dosing) and narrowband ultraviolet B (NB-UVB) phototherapy three times weekly for an additional twelve weeks. Noticeable improvement was noted after the addition of NB-UVB and the patient's promising response to phototherapy influenced further management. Etanercept and NB-UVB were discontinued and the patient was initiated on excimer laser treatments twice weekly. After 4 weeks, the patient had a 75 percent reduction in Psoriasis Area Severity Index (PASI) score and after 7 weeks had over 95 percent clearance of psoriasis. The unique properties of the excimer laser may account for its clinical efficacy in our patient as well as in other cases of recalcitrant psoriasis. We propose that the excimer laser be considered in cases of biologic or conventional phototherapy failure in addition to being a standard treatment option or adjunct for the treatment of psoriasis.

  11. Study on the electromagnetic radiation characteristics of discharging excimer laser system

    NASA Astrophysics Data System (ADS)

    Zhao, Duliang; Liang, Xu; Fang, Xiaodong; Wang, Qingsheng

    2016-10-01

    Excimer laser in condition of high voltage, large current and fast discharge will produce strong electromagnetic pulse radiation and electromagnetic interference on the around electrical equipment. The research on characteristics and distribution of excimer laser electromagnetic radiation could provide important basis for electromagnetic shielding and suppressing electromagnetic interference, and further improving the electromagnetic compatibility of system. Firstly, electromagnetic radiation source is analyzed according to the working principle of excimer laser. The key test points of the electromagnetic radiation, hydrogen thyratron, main discharge circuit and laser outlet, are determined by the mechanical structure and the theory of electromagnetic radiation. Secondly, characteristics of electromagnetic field were tested using a near field probe on the key positions of the vertical direction at 20, 50, and 80 cm, respectively. The main radiation frequencies and the radiation field characteristics in the near field are obtained. The experimental results show that the main radiation frequencies distribute in 47, 65, and 130 MHz for electric field and the main radiation frequencies distribute in 34, 100, and 165 MHz for magnetic field. The intensity of electromagnetic field decreases rapidly with the increase of test distance. The higher the frequency increases, the faster the amplitude attenuate. Finally, several electromagnetic interference suppression measurement methods are proposed from the perspective of electromagnetic compatibility according to the test results.

  12. Current status and future perspectives of electron interactions with molecules, clusters, surfaces, and interfaces [Workshop on Fundamental challenges in electron-driven chemistry; Workshop on Electron-driven processes: Scientific challenges and technological opportunities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Becker, Kurt H.; McCurdy, C. William; Orlando, Thomas M.

    2000-09-01

    This report is based largely on presentations and discussions at two workshops and contributions from workshop participants. The workshop on Fundamental Challenges in Electron-Driven Chemistry was held in Berkeley, October 9-10, 1998, and addressed questions regarding theory, computation, and simulation. The workshop on Electron-Driven Processes: Scientific Challenges and Technological Opportunities was held at Stevens Institute of Technology, March 16-17, 2000, and focused largely on experiments. Electron-molecule and electron-atom collisions initiate and drive almost all the relevant chemical processes associated with radiation chemistry, environmental chemistry, stability of waste repositories, plasma-enhanced chemical vapor deposition, plasma processing of materials for microelectronic devices andmore » other applications, and novel light sources for research purposes (e.g. excimer lamps in the extreme ultraviolet) and in everyday lighting applications. The life sciences are a rapidly advancing field where the important role of electron-driven processes is only now beginning to be recognized. Many of the applications of electron-initiated chemical processes require results in the near term. A large-scale, multidisciplinary and collaborative effort should be mounted to solve these problems in a timely way so that their solution will have the needed impact on the urgent questions of understanding the physico-chemical processes initiated and driven by electron interactions.« less

  13. Measurement of sigma(Lambda(b)0) / sigma(anti-B 0) x B(Lambda0(b) ---> Lambda+(c) pi-) / B(anti-B0 ---> D+ pi-) in p anti-p collisions at S**(1/2) = 1.96-TeV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abulencia, A.; Acosta, D.; Adelman, Jahred A.

    2006-01-01

    The authors present the first observation of the baryon decay {Lambda}{sub b}{sup 0} {yields} {Lambda}{sub c}{sup +} {pi}{sup -} followed by {Lambda}{sub c}{sup +} {yields} pK{sup -} {pi}{sup +} in 106 pb{sup -1} p{bar p} collisions at {radical}s = 1.96 TeV in the CDF experiment. IN order to reduce systematic error, the measured rate for {Lambda}{sub b}{sup 0} decay is normalized to the kinematically similar meson decay {bar B}{sup 0} {yields} D{sup +}{pi}{sup -} followed by D{sup +} {yields} {pi}{sup +}K{sup -}{pi}{sup +}. They report the ratio of production cross sections ({sigma}) times the ratio of branching fractions ({Beta}) formore » the momentum region integrated above p{sub T} > 6 GeV/c and pseudorapidity range |{eta}| < 1.3: {sigma}(p{bar p} {yields} {Lambda}{sub b}{sup 0}X)/{sigma}(p{bar p} {yields} {bar B}{sup 0} X) x {Beta}({Lambda}{sub b}{sup 0} {yields} {Lambda}{sub c}{sup +}{pi}{sup -})/{Beta}({bar B}{sup 0} {yields} D{sup +}{pi}{sup -}) = 0.82 {+-} 0.08(stat) {+-} 0.11(syst) {+-} 0.22 ({Beta}({Lambda}{sub c}{sup +} {yields} pK{sup -} {pi}{sup +})).« less

  14. Inhibitory effect of tocotrienol on eukaryotic DNA polymerase {lambda} and angiogenesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mizushina, Yoshiyuki; Nakagawa, Kiyotaka; Shibata, Akira

    2006-01-20

    Tocotrienols, vitamin E compounds that have an unsaturated side chain with three double bonds, selectively inhibited the activity of mammalian DNA polymerase {lambda} (pol {lambda}) in vitro. These compounds did not influence the activities of replicative pols such as {alpha}, {delta}, and {epsilon}, or even the activity of pol {beta} which is thought to have a very similar three-dimensional structure to the pol {beta}-like region of pol {lambda}. Since {delta}-tocotrienol had the strongest inhibitory effect among the four ({alpha}- to {delta}-) tocotrienols, the isomer's structure might be an important factor in the inhibition of pol {lambda}. The inhibitory effect ofmore » {delta}-tocotrienol on both intact pol {lambda} (residues 1-575) and a truncated pol {lambda} lacking the N-terminal BRCA1 C-terminus (BRCT) domain (residues 133-575, del-1 pol {lambda}) was dose-dependent, with 50% inhibition observed at a concentration of 18.4 and 90.1 {mu}M, respectively. However, del-2 pol {lambda} (residues 245-575) containing the C-terminal pol {beta}-like region was unaffected. Tocotrienols also inhibited the proliferation of and formation of tubes by bovine aortic endothelial cells, with {delta}-tocotrienol having the greatest effect. These results indicated that tocotrienols targeted both pol {lambda} and angiogenesis as anti-cancer agents. The relationship between the inhibition of pol {lambda} and anti-angiogenesis by {delta}-tocotrienol was discussed.« less

  15. The formation of low-ionization emission in the halo of NGC 891

    NASA Technical Reports Server (NTRS)

    Sokolowski, James; Bland-Hawthorn, Jonathan

    1993-01-01

    Imaging and Spectroscopic study first revealed the presence of a diffuse ionized medium (DIM), having unusual excitation, pervading the lower halo of the edge-on spiral galaxy NGC 891. Emission from this DIM is strongest northeast of the nucleus, at radii between 2 and 8 kpc (hereafter region 1). The (N2)(lambda)6583/H(alpha) and (S2)(lambda) (lambda)6716,6731/H(alpha) ratios increase dramatically with z in region 1, from 0.6 and 0.5 respectively at z is approximately equal to 500 pc to 1.1 and 1.0 at z is approximately equal to 1 kpc, while nondetections of (O1)(lambda)6300 and (O3)(lambda)5007 emission yield upper limits of (O1)(lambda)6300/H(alpha) less than or equal to 0.05 and (O3)(lambda)5007/H(alpha) less than or equal to 0.15 for z less than 1 kpc. Previous photoionization models, using the radiation field from disk O and B stars, have been successful in reproducing the elevated (N2)(lambda)6583/H(alpha) and (S2)(lambda)(lambda)6716.6731/H(alpha) ratios observed. However, these radiation bounded models also produce significant (O3)(lambda)5007 emission, in conflict with the observed upper limit. Here, we report the results of new, matter bounded models for the photoionization of the DIM in region 1 of NGC 891.

  16. Measurement of the Lambda(0)(b) lifetime in the exclusive decay Lambda(0)(b) -> J/psi Lambda(0) in p(p)over-bar collisions at root s=1.96 TeV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abazov V. M.; Abbott, B.; Acharya, B. S.

    2012-06-07

    We measure the {Lambda}{sub b}{sup 0} lifetime in the fully reconstructed decay {Lambda}{sub b}{sup 0} {yields} J/{psi}{Lambda}{sup 0} using 10.4 fb{sup -1} of p{bar p} collisions collected with the D0 detector at {radical}s = 1.96 TeV. The lifetime of the topologically similar decay channel B{sup 0} {yields} J/{psi}K{sub S}{sup 0} is also measured. We obtain {tau}({Lambda}{sub b}{sup 0}) = 1.303 {+-} 0.075(stat) {+-} 0.035(syst) ps and {tau}(B{sup 0}) = 1.508 {+-} 0.025(stat) {+-} 0.043(syst) ps. Using these measurements, we determine the lifetime ratio of {tau}({Lambda}{sub b}{sup 0})/{tau}(B{sup 0}) = 0.864 {+-} 0.052(stat) {+-} 0.033(syst).

  17. Pulsed excimer laser processing for cost-effective solar cells

    NASA Technical Reports Server (NTRS)

    Wong, David C.

    1985-01-01

    The application of excimer laser in the fabrication of photovoltaic devices was investigated extensively. Processes included junction formation, laser assisted chemical vapor deposition metallization, and laser assisted chemical vapor deposition surface passivation. Results demonstrated that implementation of junction formation by laser annealing in production is feasible because of excellent control in junction depth and quality. Both metallization and surface passivation, however, were found impractical to be considered for manufacturing at this stage.

  18. Physical and optical limitations using ArF-excimer and Er:YAG lasers for PRK

    NASA Astrophysics Data System (ADS)

    Semchishen, Vladimir A.; Mrochen, Michael; Seiler, Theo

    1998-06-01

    The Erbium:YAG laser emitting at a wavelength of 2,94 micrometer have been promised as an alternative laser for the ArF-excimer laser (193 nm) in photorefractive keratectomy (PRK). This report discusses the limitations of laser parameters such as wavelength, energy density and pulse duration for the ablation of the cornea. In addition, the melting process during ablation on the corneal surface roughness may play a role.

  19. Improved model for the angular dependence of excimer laser ablation rates in polymer materials

    NASA Astrophysics Data System (ADS)

    Pedder, J. E. A.; Holmes, A. S.; Dyer, P. E.

    2009-10-01

    Measurements of the angle-dependent ablation rates of polymers that have applications in microdevice fabrication are reported. A simple model based on Beer's law, including plume absorption, is shown to give good agreement with the experimental findings for polycarbonate and SU8, ablated using the 193 and 248 nm excimer lasers, respectively. The modeling forms a useful tool for designing masks needed to fabricate complex surface relief by ablation.

  20. Excimer laser interaction with dentin of the human tooth

    NASA Technical Reports Server (NTRS)

    Hammond, Ernest C., Jr.; Gilliam, Ruth L.; Baker, George R.

    1989-01-01

    The use an excimer laser produced many unusual conical structures within the dentin of the inner part of the human tooth. By varying the frequency of the laser one can disperse the energy and cause more bleeding in laser surgery, but not destroy the cells associated with the incision. Therefore, the healing process will virtually be without scarring. Whereas, using the infrared laser the blood loss would be less, but the healing process would tend to be longer because cells are being destroyed due to the cauterization effect of the laser. The question is, are these structures produced as an interaction with the laser or are they an intrinsic part of the structure. The effects of the laser interaction upon dentin was studied, and in using electron microscopy the interaction of the excimer laser upon the tooth dentin and other various biological tissue is more clearly understood.

  1. Corneal limbal marking in the treatment of myopic astigmatism with the excimer laser.

    PubMed

    Bucher, Celine; Zuberbuhler, Bruno; Goggin, Michael; Esterman, Adrian; Schipper, Isaak

    2010-07-01

    To determine whether preoperative marking of the limbal cornea improves treatment of myopic astigmatism with the excimer laser. Retrospective study on 108 eyes with myopic astigmatism that underwent LASIK or laser epithelial keratomileusis (LASEK) with the Technolas 217 (Bausch & Lomb) excimer laser. Preoperative limbal marking was performed in 47 eyes (marked group). The 12-month results were used for refractive and visual analysis. The achieved cylinder reduction, spherical reduction, and refractive predictability were similar for the marked and unmarked groups in the overall study collective, in the LASIK and LASEK subgroup analysis, and in a higher astigmatism (> 1.25 diopters) subgroup analysis. Limbal marking showed no influence on the refractive results, and vector analysis showed no significant difference in angle of error among groups. Corneal limbal marking failed to improve the refractive outcome in LASIK and LASEK for myopic astigmatism.

  2. Excited-state dynamics of bis(9-fluorenyl)methane and its derivative 9-(9-ethylfluorenyl)-9'-fluorenylmethane: steric effect on energetics and dynamics of ground- and excited-state conformations.

    PubMed

    Boo, Bong Hyun; Lee, Minyung; Jeon, Ki-Seok; Kim, Seung-Joon

    2014-03-27

    Intramolecular excimer formation of bis(9-fluorenyl)methane (BFM) and 9-(9'-ethylfluorenyl)-9-fluorenylmethane (EFFM), in which an ethyl group is substituted to a 9-H atom in BFM, was studied by means of steady-state and time-resolved fluorescence. Ab initio and DFT calculations enabled the prediction of three conformers as stable species of orthogonal, trans-gauche, and gauche-gauche. The theoretical and experimental results reveal that the substitution effect is also found to appreciably influence the energies, spectroscopy, and kinetics associated with the interconversion of various conformers of the diaryl compounds. We have not observed the rising components in the excimer fluorescence decay of BFM and EFFM in PMMA as observed in the liquid solutions probably because of the existence of the sandwich conformer responsible for the excimer fluorescence prior to the laser irradiation.

  3. Excimer laser decontamination

    NASA Astrophysics Data System (ADS)

    Sentis, Marc L.; Delaporte, Philippe C.; Marine, Wladimir; Uteza, Olivier P.

    2000-04-01

    The application of excimer laser ablation process to the decontamination of radioactive surfaces is discussed. This technology is very attractive because it allows to efficiently remove the contaminated particles without secondary waste production. To demonstrate the capability of such technology to efficiently decontaminate large area, we studied and developed a prototype which include a XeCl laser, an optical fiber delivery system and an ablated particles collection cell. The main physical processes taking place during UV laser ablation will be explained. The influence of laser wavelength, pulse duration and absorption coefficient of material will be discussed. Special studies have been performed to understand the processes which limit the transmission of high average power excimer laser through optical fiber, and to determine the laser conditions to optimize the value of this transmission. An in-situ spectroscopic analysis of laser ablation plasma allows the real time control of the decontamination. The results obtained for painting or metallic oxides removal from stainless steel surfaces will be presented.

  4. System for the design, manufacture, and testing of custom lenses with known amounts of high-order aberrations.

    PubMed

    Chernyak, Dimitri A; Campbell, Charles E

    2003-11-01

    Now that excimer laser systems can be programmed to correct complex aberrations of the eye on the basis of wave-front measurements, a method is needed to test the accuracy of the system from measurement through treatment. A closed-loop test method was developed to ensure that treatment plans generated by a wavefront measuring system were accurately transferred to and executed by the excimer laser. A surface was analytically defined, and a Shack-Hartmann-based wave-front system was used to formulate a treatment plan, which was downloaded to an excimer laser system. A plastic lens was ablated by the laser and then returned to the wave-front device, where it was measured and compared with the analytically defined wave-front surface. The two surfaces agreed up to 6th-order Zernike terms, validating the accuracy of the system.

  5. Generation of strongly coupled plasmas by high power excimer laser

    NASA Astrophysics Data System (ADS)

    Zhu, Yongxiang; Liu, Jingru; Zhang, Yongsheng; Hu, Yun; Zhang, Jiyan; Zheng, Zhijian; Ye, Xisheng

    2013-05-01

    (ultraviolet). To generate strongly coupled plasmas (SCP) by high power excimer laser, an Au-CH-Al-CH target is used to make the Al sample reach the state of SCP, in which the Au layer transforms laser energy to X-ray that heating the sample by volume and the CH layers provides necessary constraints. With aid of the MULTI-1D code, we calculate the state of the Al sample and its relationship with peak intensity, width and wavelength of laser pulses. The calculated results suggest that an excimer laser with peak intensity of the magnitude of 1013W/cm2 and pulse width being 5ns - 10ns is suitable to generate SCP with the temperature being tens of eV and the density of electron being of the order of 1022/cm-3. Lasers with shorter wavelength, such as KrF laser, are preferable.

  6. Triggering Excimer Lasers by Photoionization from Corona Discharges

    NASA Astrophysics Data System (ADS)

    Xiong, Zhongmin; Duffey, Thomas; Brown, Daniel; Kushner, Mark

    2009-10-01

    High repetition rate ArF (192 nm) excimer lasers are used for photolithography sources in microelectronics fabrication. In highly attaching gas mixtures, preionization is critical to obtaining stable, reproducible glow discharges. Photoionization from a separate corona discharge is one technique for preionization which triggers the subsequent electron avalanche between the main electrodes. Photoionization triggering of an ArF excimer laser sustained in multi-atmosphere Ne/Ar/F2/Xe gas mixtures has been investigated using a 2-dimensional plasma hydrodynamics model including radiation transport. Continuity equations for charged and neutral species, and Poisson's equation are solved coincident with the electron temperature with transport coefficients obtained from solutions of Boltzmann's equation. Photoionizing radiation is produced by a surface discharge which propagates along a corona-bar located adjacent to the discharge electrodes. The consequences of pulse power waveform, corona bar location, capacitance and gas mixture on uniformity, symmetry and gain of the avalanche discharge will be discussed.

  7. A Randomized Study of Peginterferon Lambda-1a Compared to Peginterferon Alfa-2a in Combination with Ribavirin and Telaprevir in Patients with Genotype-1 Chronic Hepatitis C.

    PubMed

    Flisiak, Robert; Shiffman, Mitchell; Arenas, Juan; Cheinquer, Hugo; Nikitin, Igor; Dong, Yuping; Rana, Khurram; Srinivasan, Subasree

    2016-01-01

    A randomized, double-blind, multinational, phase 3 study was conducted comparing the efficacy and safety of peginterferon lambda-1a (Lambda)/ribavirin (RBV)/telaprevir (TVR) vs. peginterferon alfa-2a (Alfa)/RBV/TVR in patients with chronic hepatitis C virus (HCV) genotype-1 (GT-1) infection. Patients (treatment-naïve or relapsers on prior Alfa/RBV treatment) were randomly assigned in a 2:1 ratio to receive Lambda/RBV/TVR or Alfa/RBV/TVR. Total duration of treatment was either 24 or 48 weeks (response-guided treatment), with TVR administered for the first 12 weeks. The primary endpoint was the proportion of patients who achieved a sustained virologic response at post treatment week 12 (SVR12), which was tested for noninferiority of Lambda/RBV/TVR. A total of 838 patients were enrolled, and 617 were treated; 411 and 206 patients received Lambda/RBV/TVR and Alfa/RBV/TVR, respectively. The majority of patients were treatment-naïve, with HCV GT-1b and a high baseline viral load (≥800,000 IU/mL). Less than 10% of patients had cirrhosis (Lambda, 7.5%; Alfa, 6.8%). Lambda/RBV/TVR did not meet the criterion for noninferiority (lower bound of the treatment difference interval was -12.3%); the SVR12 in all patients (modified intent-to-treat) was 76.2% in the Lambda arm and 82.0% in the Alfa arm. Overall, the frequency of adverse events in each arm was comparable (Lambda, 91.7%; Alfa, 97.1%). As expected based on the safety profile of the 2 interferons, there were more hepatobiliary events observed in the Lambda arm and more hematologic events in the Alfa arm. In this comparison of Lambda/RBV/TVR and Alfa/RBV/TVR in patients who were treatment-naïve or had relapsed on prior Alfa/RBV treatment, Lambda failed to demonstrate noninferiority based on SVR12 results. Treatment with Lambda/RBV/TVR was associated with a higher incidence of relapse. More patients discontinued Lambda/RBV/TVR treatment during the first 4 weeks of study treatment, mainly due to hepatobiliary-related events, and more Lambda patients were lost to follow-up.

  8. Apparatus and method for closed-loop control of reactor power in minimum time

    DOEpatents

    Bernard, Jr., John A.

    1988-11-01

    Closed-loop control law for altering the power level of nuclear reactors in a safe manner and without overshoot and in minimum time. Apparatus is provided for moving a fast-acting control element such as a control rod or a control drum for altering the nuclear reactor power level. A computer computes at short time intervals either the function: .rho.=(.beta.-.rho.).omega.-.lambda..sub.e '.rho.-.SIGMA..beta..sub.i (.lambda..sub.i -.lambda..sub.e ')+l* .omega.+l* [.omega..sup.2 +.lambda..sub.e '.omega.] or the function: .rho.=(.beta.-.rho.).omega.-.lambda..sub.e .rho.-(.lambda..sub.e /.lambda..sub.e)(.beta.-.rho.)+l* .omega.+l* [.omega..sup.2 +.lambda..sub.e .omega.-(.lambda..sub.e /.lambda..sub.e).omega.] These functions each specify the rate of change of reactivity that is necessary to achieve a specified rate of change of reactor power. The direction and speed of motion of the control element is altered so as to provide the rate of reactivity change calculated using either or both of these functions thereby resulting in the attainment of a new power level without overshoot and in minimum time. These functions are computed at intervals of approximately 0.01-1.0 seconds depending on the specific application.

  9. Lysosome-associated membrane proteins-1 and -2 (LAMP-1 and LAMP-2) assemble via distinct modes.

    PubMed

    Terasawa, Kazue; Tomabechi, Yuri; Ikeda, Mariko; Ehara, Haruhiko; Kukimoto-Niino, Mutsuko; Wakiyama, Motoaki; Podyma-Inoue, Katarzyna A; Rajapakshe, Anupama R; Watabe, Tetsuro; Shirouzu, Mikako; Hara-Yokoyama, Miki

    2016-10-21

    Lysosome-associated membrane proteins 1 and 2 (LAMP-1 and LAMP-2) have a large, heavily glycosylated luminal domain composed of two subdomains, and are the most abundant protein components in lysosome membranes. LAMP-1 and LAMP-2 have distinct functions, and the presence of both proteins together is required for the essential regulation of autophagy to avoid embryonic lethality. However, the structural aspects of LAMP-1 and LAMP-2 have not been elucidated. In the present study, we demonstrated that the subdomains of LAMP-1 and LAMP-2 adopt the unique β-prism fold, similar to the domain structure of the dendritic cell-specific-LAMP (DC-LAMP, LAMP-3), confirming the conserved aspect of this family of lysosome-associated membrane proteins. Furthermore, we evaluated the effects of the N-domain truncation of LAMP-1 or LAMP-2 on the assembly of LAMPs, based on immunoprecipitation experiments. We found that the N-domain of LAMP-1 is necessary, whereas that of LAMP-2 is repressive, for the organization of a multimeric assembly of LAMPs. Accordingly, the present study suggests for the first time that the assembly modes of LAMP-1 and LAMP-2 are different, which may underlie their distinct functions. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. On Spectral Invariance of Single Scattering Albedo for Weakly Absorbing Wavelengths

    NASA Technical Reports Server (NTRS)

    Marshak, Alexander; Knyazikhin, Yuri; Chiu, J. Christine; Wiscombe, Warren J.

    2011-01-01

    This note shows that for water droplets at weakly absorbing wavelengths, the ratio omega(sub O lambda(r))/omega(sub O lambda(r(sub O)) of two single scattering albedo spectra, omega(sub O lambda(r) and omega(sub O lambda(r (sub O)), is a linear function of omega(sub O lambda(r). The slope and intercept of the linear function are wavelength independent and sum to unity. This relationship allows for a representation of any single scattering albedo omega(sub O lambda(r) via one known spectrum omega(sub O lambda(r(sub O)). The note provides a simple physical explanation of the discovered relationship. In addition to water droplets, similar linear relationships were found for the single scattering albedo of non-spherical ice crystals.

  11. Pegylated interferons Lambda-1a and alfa-2a display different gene induction and cytokine and chemokine release profiles in whole blood, human hepatocytes and peripheral blood mononuclear cells.

    PubMed

    Freeman, J; Baglino, S; Friborg, J; Kraft, Z; Gray, T; Hill, M; McPhee, F; Hillson, J; Lopez-Talavera, J C; Wind-Rotolo, M

    2014-06-01

    Pegylated interferon-lambda-1a (Lambda), a type III interferon (IFN) in clinical development for the treatment of chronic HCV infection, has shown comparable efficacy and an improved safety profile to a regimen based on pegylated IFN alfa-2a (alfa). To establish a mechanistic context for this improved profile, we investigated the ex vivo effects of Lambda and alfa on cytokine and chemokine release, and on expression of IFN-stimulated genes (ISGs) in primary human hepatocytes and peripheral blood mononuclear cells (PBMCs) from healthy subjects. Our findings were further compared with changes observed in blood analysed from HCV-infected patients treated with Lambda or alfa in clinical studies. mRNA transcript and protein expression of the IFN-λ-limiting receptor subunit was lower compared with IFN-α receptor subunits in all cell types. Upon stimulation, alfa and Lambda induced ISG expression in hepatocytes and PBMCs, although in PBMCs Lambda-induced ISG expression was modest. Furthermore, alfa and Lambda induced release of cytokines and chemokines from hepatocytes and PBMCs, although differences in their kinetics of induction were observed. In HCV-infected patients, alfa treatment induced ISG expression in whole blood after single and repeat dosing. Lambda treatment induced modest ISG expression after single dosing and showed no induction after repeat dosing. Alfa and Lambda treatment increased IP-10, iTAC, IL-6, MCP-1 and MIP-1β levels in serum, with alfa inducing higher levels of all mediators compared with Lambda. Overall, ex vivo and in vivo induction profiles reported in this analysis strongly correlate with clinical observations of fewer related adverse events for Lambda vs those typically associated with alfa. © 2014 John Wiley & Sons Ltd.

  12. Environmental chemistry, ecotoxicity, and fate of lambda-cyhalothrin.

    PubMed

    He, Li-Ming; Troiano, John; Wang, Albert; Goh, Kean

    2008-01-01

    Lambda-cyhalothrin is a pyrethroid insecticide used for controlling pest insects in agriculture, public health, and in construction and households. Lambda-cyhalothrin is characterized by low vapor pressure and a low Henry's law constant but by a high octanol-water partition coefficient (K(ow)) and high water-solid-organic carbon partition coefficient (K(oc)) values. Lambda-cyhalothrin is quite stable in water at pH < 8, whereas it hydrolyzes to form HCN and aldehyde under alkaline conditions. Although lambda-cyhalothrin is relatively photostable under natural irradiation, with a half-life > 3 wk, its photolysis process is fast under UV irradiation, with a half-life < 10 min. The fate of lambda-cyhalothrin in aquatic ecosystems depends on the nature of system components such as suspended solids (mineral and organic particulates) and aquatic organisms (algae, macrophytes, or aquatic animals). Lambda-cyhalothrin residues dissolved in water decrease rapidly if suspended solids and/or aquatic organisms are present because lambda-cyhalothrin molecules are strongly adsorbed by particulates and plants. Adsorbed lambda-cyhalothrin molecules show decreased degradation rates because they are less accessible to breakdown than free molecules in the water column. On the other hand, lambda-cyhalothrin adsorbed to suspended solids or bottom sediments may provide a mechanism to mitigate its acute toxicity to aquatic organisms by reducing their short-term bioavailability in the water column. The widespread use of lambda-cyhalothrin has resulted in residues in sediment, which have been found to be toxic to aquatic organisms including fish and amphipods. Mitigation measures have been used to reduce the adverse impact of lambda-cyhalothrin contributed from agricultural or urban runoff. Mitigation may be achieved by reducing the quantity of runoff and suspended solid content in runoff through wetlands, detention ponds, or vegetated ditches.

  13. Non-LTE radiative transfer with lambda-acceleration - Convergence properties using exact full and diagonal lambda-operators

    NASA Technical Reports Server (NTRS)

    Macfarlane, J. J.

    1992-01-01

    We investigate the convergence properties of Lambda-acceleration methods for non-LTE radiative transfer problems in planar and spherical geometry. Matrix elements of the 'exact' A-operator are used to accelerate convergence to a solution in which both the radiative transfer and atomic rate equations are simultaneously satisfied. Convergence properties of two-level and multilevel atomic systems are investigated for methods using: (1) the complete Lambda-operator, and (2) the diagonal of the Lambda-operator. We find that the convergence properties for the method utilizing the complete Lambda-operator are significantly better than those of the diagonal Lambda-operator method, often reducing the number of iterations needed for convergence by a factor of between two and seven. However, the overall computational time required for large scale calculations - that is, those with many atomic levels and spatial zones - is typically a factor of a few larger for the complete Lambda-operator method, suggesting that the approach should be best applied to problems in which convergence is especially difficult.

  14. Mass and K{lambda} Coupling of the N*(1535)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, B.C.; Graduate School of the Chinese Academy of Sciences, Beijing 100049; Zou, B.S.

    2006-02-03

    Using a resonance isobar model and an effective Lagrangian approach, from recent BES results on J/{psi}{yields}pp{eta} and {psi}{yields}pK{sup +}{lambda}, we deduce the ratio between effective coupling constants of N*(1535) to K{lambda} and p{eta} to be R{identical_to}g{sub N*(1535)K{lambda}}/g{sub N*(1535)p{eta}}=1.3{+-}0.3. With the previous known value of g{sub N*(1535)p{eta}}, the obtained new value of g{sub N*(1535)K{lambda}} is shown to reproduce recent pp{yields}pK{sup +}{lambda} near-threshold cross section data as well. Taking into account this large N*K{lambda} coupling in the coupled channel Breit-Wigner formula for the N*(1535), its Breit-Wigner mass is found to be around 1400 MeV, much smaller than the previous value of aboutmore » 1535 MeV obtained without including its coupling to K{lambda}. The implication on the nature of N*(1535) is discussed.« less

  15. Peginterferon lambda for the treatment of HBeAg-positive chronic hepatitis B: A randomized phase 2b study (LIRA-B).

    PubMed

    Chan, Henry L Y; Ahn, Sang Hoon; Chang, Ting-Tsung; Peng, Cheng-Yuan; Wong, David; Coffin, Carla S; Lim, Seng Gee; Chen, Pei-Jer; Janssen, Harry L A; Marcellin, Patrick; Serfaty, Lawrence; Zeuzem, Stefan; Cohen, David; Critelli, Linda; Xu, Dong; Wind-Rotolo, Megan; Cooney, Elizabeth

    2016-05-01

    Peginterferon lambda-1a (lambda) is a Type-III interferon, which, like alfa interferons, has antiviral activity in vitro against hepatitis B virus (HBV) and hepatitis C virus (HCV); however, lambda has a more limited extra-hepatic receptor distribution. This phase 2b study (LIRA-B) evaluated lambda in patients with chronic HBV infection. Adult HBeAg+ interferon-naive patients were randomized (1:1) to weekly lambda (180 μg) or peginterferon alfa-2a (alfa) for 48 weeks. The primary efficacy endpoint was HBeAg seroconversion at week 24 post-treatment; lambda non-inferiority was demonstrated if the 80% confidence interval (80% CI) lower bound was >-15%. Baseline characteristics were balanced across groups (lambda N=80; alfa N=83). Early on-treatment declines in HBV-DNA and qHBsAg through week 24 were greater with lambda. HBeAg seroconversion rates were comparable for lambda and alfa at week 48 (17.5% vs. 16.9%, respectively); however lambda non-inferiority was not met at week 24 post-treatment (13.8% vs. 30.1%, respectively; lambda vs. alfa 80% CI lower bound -24%). Results for other key secondary endpoints (virologic, serologic, biochemical) and post hoc combined endpoints (HBV-DNA <2000 IU/ml plus HBeAg seroconversion or ALT normalization) mostly favored alfa. Overall adverse events (AE), serious AE, and AE-discontinuation rates were comparable between arms but AE-spectra differed (more cytopenias, flu-like, and musculoskeletal symptoms observed with alfa, more ALT flares and bilirubin elevations seen with lambda). Most on-treatment flares occurred early (weeks 4-12), associated with HBV-DNA decline; all post-treatment flares were preceded by HBV-DNA rise. On-treatment, lambda showed greater early effects on HBV-DNA and qHBsAg, and comparable serologic/virologic responses at end-of-treatment. However, post-treatment, alfa-associated HBeAg seroconversion rates were higher, and key secondary results mostly favored alfa. ClinicalTrials.gov number: NCT01204762. Copyright © 2016 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  16. Electromagnetic Radiation: Final Range Environmental Assessment, Revision 1

    DTIC Science & Technology

    2009-12-03

    scanning, research, and medical treatment and surgical procedures. There are many different types of lasing materials as identified below ( Indiana ...vapor (red) 0.627 Xenon chloride (Excimer-UV) 0.308 Helium neon (red) 0.633 Xenon fluoride (Excimer-UV) 0.351 Krypton (red) 0.647 Helium cadmium (UV...0.325 Rhodamine 6G dye (tunable) 0.570-0.650 Nitrogen (UV) 0.337 Ruby (CrAlO3) (red) 0.694 Helium cadmium (violet) 0.441 Gallium arsenide (diode

  17. Pyrene-based chemosens or detects picric acid upto attogram level through aggregation enhanced excimer emission.

    PubMed

    Chopra, Rakesh; Kaur, Paramjit; Singh, Kamaljit

    2015-03-15

    A pyrene-based small molecular weight probe, exhibiting aggregation enhanced excimer emission has been synthesized. The crystalline emissive form detects 2,4,6-trinitrophenol (picric acid) at parts-per-billion concentration in solution and as low as 0.46 attogram in direct contact mode, operating predominantly in a static quenching mechanism, proposed on the basis of steady state and life-time fluorescence measurements. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. An intense radiation in mid-infrared of Xe

    NASA Astrophysics Data System (ADS)

    He, Shan; Liu, Dong; Guo, Jingwei; Sang, Fengting

    2017-01-01

    Recently, the optically pumped rare gas lasers have been attracted extensive attention. Rare gas laser systems with Ne (2p53p), Ar (3p54p), and Kr (4p55p) atoms have been investigated. However, there are sparse studies based on Xe. In this work, new phenomena, intensive mid-infrared amplified spontaneous emissions (ASEs), are found after two-photon excitation of Xe from the ground state to the 6p[1/2]0 state. Simultaneously, substantial 6p[1/2]1 atoms are populated. The thresholds of ASE peak 1 and the generation of 6p[1/2]1 atoms are both about 1.5 mJ. It indicates that there should exist the relationship between these two phenomena. The ASE signals show broadband spectra. Therefore, it must be yielded by the superposition of Xe2* excimer transitions. The mid-infrared ASEs lead to excimers correlating to the 6s'[1/2]1 enormously generated. Then these excimers dissociate to produce substantial 6p[1/2]1 atoms. Under some circumstance, the ratio of the 6p[1/2]1 to 6p[1/2]0 atoms reaches about 80%. It indicates that the 6p[1/2]0 atoms strongly tend to decay through the emissions between the excimer states. Using these emissions, continuous-tunable mid-infrared laser with metastable Xe can be promisingly produced.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Razhev, A M; Kargapol'tsev, E S; Churkin, D S

    Results of an experimental study of the influence of a gas mixture (laser active medium) composition on an output energy and total efficiency of gas-discharge excimer lasers on ArF* (193 nm), KrCl* (222 nm), KrF* (248 nm) and XeCl* (308 nm) molecules operating without a buffer gas are presented. The optimal ratios of gas components (from the viewpoint of a maximum output energy) of an active medium are found, which provide an efficient operation of laser sources. It is experimentally confirmed that for gas-discharge excimer lasers on halogenides of inert gases the presence of a buffer gas in an activemore » medium is not a necessary condition for efficient operation. For the first time, in two-component gas mixtures of repetitively pulsed gas-discharge excimer lasers on electron transitions of excimer molecules ArF*, KrCl*, KrF* and XeCl*, the pulsed energy of laser radiation obtained under pumping by a transverse volume electric discharge in a low-pressure gas mixture without a buffer gas reached up to 170 mJ and a high pulsed output power (of up to 24 MW) was obtained at a FWHM duration of the KrF-laser pulse of 7 ns. The maximal total efficiency obtained in the experiment with two-component gas mixtures of KrF and XeCl lasers was 0.8%. (lasers)« less

  20. [Indomethacin (indocollyre) versus diclofenac (voltarene) for the control of pain following excimer photoablation].

    PubMed

    Cochener, B; Kling, F; Savary-Le Floch, G; Colin, J

    2000-06-01

    To compare effect of two topical non steroidal anti-inflammatory (NSAI) drugs: Indomethacin (Indocollyre)0.1 %, Chauvin Inc.) and Diclofenac (Voltaren 0.1%, Cibavision) on postoperative pain and epithelial regrowth following surface excimer photoablation. Eighty-six excimer operated patients, were divided in two similar groups depending on the NSAI instilled postoperatively and for 3 days (4 drops daily). No patient was informed of any other available drug. Pain intensity was quantified between 1 and 10 according to an analog scale (reported from 1 to 10 hours, then 4 times a day during 7 days). Complementary medications and functional symptoms were also notified. Biomicroscopic evaluation using fluorescein test was performed to assess reepithelialization. In term of pain, no significative difference was observed between the two groups concerning intensity, associated medications, or numbers of days of discomfort. Controversially, retreated eyes might induce more pain than initial treatments. No delay in epithelial regrowth was noted and the difference between the two groups in functional complaints was no statistically significant. Pain appears to be not related to ablation depth. DISCUSSION- CONCLUSION: Our results are correlated to literature reported data. Introduction of NSAI constitutes a real advent in the care of excimer postoperative pain. Effect of indomethacin seems comparable to diclofenac effect, but might be of interest because of no anesthetic property that might guarantee of no delay in wound healing response.

  1. First Observation of Charmed Resonances in the $$\\Lambda^0_b \\to \\Lambda^+_c \\pi^- \\pi^+ \\pi^-$$ Inclusive Decay and Measurement of Their Relative Branching Ratios at CDF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barria, Patrizia

    2012-01-01

    We present the observation of themore » $$\\Lambda^0_b$$ decay into a $$\\Lambda^+_c \\pi^- \\pi^+ \\pi^-$$ final state, in $$p\\bar{p}$$ collisions at $$\\sqrt{s}$$ = 1:96 TeV. The data analyzed were collected by the CDF II detector at the Fermilab Tevatron collider, and correspond to 2:4 $$fb^{-1}$$ of integrated luminosity. We fit the invariant mass distribution of the reconstructed candidates to extract a signal yield of 848 $$\\pm$$ 93 $$\\Lambda^0_b$$ into $$\\Lambda^+_c \\pi^- \\pi^+ \\pi^-$$....« less

  2. Further observations of the lambda 10830 He line in stars and their significance as a measure of stellar activity

    NASA Technical Reports Server (NTRS)

    Zirin, H.

    1975-01-01

    Measurements of the lambda 1030 He line in 198 stars are given along with data on other features in that spectral range. Nearly 80% of all G and K stars show some lambda 10830; of these, half are variable and 1/4 show emission. It was confirmed that lambda 10830 is not found in M stars, is weak in F stars, and is particularly strong in close binaries. The line is found in emission in extremely late M and S stars, along with P gamma, but P gamma is not in emission in G and K stars with lambda 10830 emissions. Variable He emission and Ti I emission are found in the RV Tauri variables R Scuti and U Mon. In R Aqr the Fe XIII coronal line lambda 10747 and a line at lambda 11012 which may be singlet He or La II are found, as well as lambda 10830 and P gamma. The nature of coronas or hot chromospheres in the various stars is discussed. It was concluded that the lambda 10830 intensity must be more or less proportional to the energy deposited in the chromosphere corona by non-thermal processes.

  3. A photon spectrometric dose-rate constant determination for the Advantage Pd-103 brachytherapy source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Zhe Jay; Bongiorni, Paul; Nath, Ravinder

    Purpose: Although several dosimetric characterizations using Monte Carlo simulation and thermoluminescent dosimetry (TLD) have been reported for the new Advantage Pd-103 source (IsoAid, LLC, Port Richey, FL), no AAPM consensus value has been established for the dosimetric parameters of the source. The aim of this work was to perform an additional dose-rate constant ({Lambda}) determination using a recently established photon spectrometry technique (PST) that is independent of the published TLD and Monte Carlo techniques. Methods: Three Model IAPD-103A Advantage Pd-103 sources were used in this study. The relative photon energy spectrum emitted by each source along the transverse axis wasmore » measured using a high-resolution germanium spectrometer designed for low-energy photons. For each source, the dose-rate constant was determined from its emitted energy spectrum. The PST-determined dose-rate constant ({sub PST}{Lambda}) was then compared to those determined by TLD ({sub TLD}{Lambda}) and Monte Carlo ({sub MC}{Lambda}) techniques. A likely consensus {Lambda} value was estimated as the arithmetic mean of the average {Lambda} values determined by each of three different techniques. Results: The average {sub PST}{Lambda} value for the three Advantage sources was found to be (0.676{+-}0.026) cGyh{sup -1} U{sup -1}. Intersource variation in {sub PST}{Lambda} was less than 0.01%. The {sub PST}{Lambda} was within 2% of the reported {sub MC}{Lambda} values determined by PTRAN, EGSnrc, and MCNP5 codes. It was 3.4% lower than the reported {sub TLD}{Lambda}. A likely consensus {Lambda} value was estimated to be (0.688{+-}0.026) cGyh{sup -1} U{sup -1}, similar to the AAPM consensus values recommended currently for the Theragenics (Buford, GA) Model 200 (0.686{+-}0.033) cGyh{sup -1} U{sup -1}, the NASI (Chatsworth, CA) Model MED3633 (0.688{+-}0.033) cGyh{sup -1} U{sup -1}, and the Best Medical (Springfield, VA) Model 2335 (0.685{+-}0.033) cGyh{sup -1} U{sup -1} {sup 103}Pd sources. Conclusions: An independent {Lambda} determination has been performed for the Advantage Pd-103 source. The {sub PST}{Lambda} obtained in this work provides additional information needed for establishing a more accurate consensus {Lambda} value for the Advantage Pd-103 source.« less

  4. 78 FR 71609 - Methiocarb, Lambda-Cyhalothrin, Permethrin and Prodiamine; Notice of Receipt of Requests To...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-29

    ... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-OPP-2009-1017; FRL-9902-77] Methiocarb, Lambda-Cyhalothrin... receipt of requests by the registrants to voluntarily amend their Methiocarb, Lambda- Cyhalothrin... Willowood Lambda Cyhalothrin LLC, Gowan Company, Farnam Companies, Inc., Pyxis Regulatory Consulting, Inc...

  5. Structural relationship of curcumin derivatives binding to the BRCT domain of human DNA polymerase lambda.

    PubMed

    Takeuchi, Toshifumi; Ishidoh, Tomomi; Iijima, Hiroshi; Kuriyama, Isoko; Shimazaki, Noriko; Koiwai, Osamu; Kuramochi, Kouji; Kobayashi, Susumu; Sugawara, Fumio; Sakaguchi, Kengo; Yoshida, Hiromi; Mizushina, Yoshiyuki

    2006-03-01

    We previously reported that phenolic compounds, petasiphenol and curcumin (diferuloylmethane), were a selective inhibitor of DNA polymerase lambda (pol lambda) in vitro. The purpose of this study was to investigate the molecular structural relationship of curcumin and 13 chemically synthesized derivatives of curcumin. The inhibitory effect on pol lambda (full-length, i.e. intact pol lambda including the BRCA1 C- terminal [BRCT] domain) by some derivatives was stronger than that by curcumin, and monoacetylcurcumin (compound 13) was the strongest pol lambda inhibitor of all the compounds tested, achieving 50% inhibition at a concentration of 3.9 microm. The compound did not influence the activities of replicative pols such as alpha, delta, and epsilon. It had no effect on pol beta activity either, although the three-dimensional structure of pol beta is thought to be highly similar to that of pol lambda. Compound 13 did not inhibit the activity of the C-terminal catalytic domain of pol lambda including the pol beta-like core, in which the BRCT motif was deleted from its N-terminal region. MALDI-TOF MS analysis demonstrated that compound 13 bound selectively to the N-terminal domain of pol lambda, but did not bind to the C-terminal region. Based on these results, the pol lambda-inhibitory mechanism of compound 13 is discussed.

  6. Serum Free Light Chains in Neoplastic Monoclonal Gammopathies: Relative Under-Detection of Lambda Dominant Kappa/Lambda Ratio, and Underproduction of Free Lambda Light Chains, as Compared to Kappa Light Chains, in Patients With Neoplastic Monoclonal Gammopathies.

    PubMed

    Lee, Won Sok; Singh, Gurmukh

    2018-07-01

    Quantitative evaluation of serum free light chains is recommended for the work up of monoclonal gammopathies. Immunoglobulin light chains are generally produced in excess of heavy chains. In patients with monoclonal gammopathy, κ/λ ratio is abnormal less frequently with lambda chain lesions. This study was undertaken to ascertain if the levels of overproduction of the two light chain types and their detection rates are different in patients with neoplastic monoclonal gammopathies. Results of serum protein electrophoresis (SPEP), serum protein immunofixation electrophoresis (SIFE), urine protein electrophoresis (UPEP), urine protein immunofixation electrophoresis (UIFE), and serum free light chain assay (SFLCA) in patients with monoclonal gammopathies were examined retrospectively. The κ/λ ratios were appropriately abnormal more often in kappa chain lesions. Ratios of κ/λ were normal in about 25% of patients with lambda chain lesions in whom free homogenous lambda light chains were detectable in urine. An illustrative case suggests underproduction of free lambda light chains, in some instances. The lower prevalence of lambda dominant κ/λ ratio in lesions with lambda light chains is estimated to be due to relative under-detection of lambda dominant κ/λ ratio in about 25% of the patients and because lambda chains are not produced in as much excess of heavy chains as are kappa chains, in about 5% of the patients. The results question the medical necessity and clinical usefulness of the serum free light chain assay. UPEP/UIFE is under-utilized.

  7. Search for CP Violation in Hyperon Decay: $$\\Xi^- / \\bar{\\Xi}^+$$ and $$\\Lambda / \\bar{\\Lambda}$$ (in French)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leros, Nicolas

    2001-06-01

    The HyperCP(EB71) experiment, performed at the Fermi National Accelerator Laboratory in the United States, provides a primary search for direct OP violation in the decays ofmore » $$\\Xi^-/\\bar{\\Xi}^+$$ and $$\\Lambda/ \\bar{\\Lambda}$$ hyperons....« less

  8. LASERS: Excimer XeCl laser excited by microsecond megawatt microwave pulses from a commercial 3.07-GHz microwave oscillator

    NASA Astrophysics Data System (ADS)

    Vaulin, V. A.; Slinko, V. N.; Sulakshin, S. S.

    1990-12-01

    An excimer laser (λ approx 308 nm) utilizing an Ne-Xe-HCl mixture was excited by microwave (ν0 = 3.07 GHz) pulses of 2.8-μs duration and ~ 0.9 MW power delivered by a commercial microwave oscillator. A peak laser radiation power of 130 W was obtained in pulses of 280 ns duration. Laser radiation from along the center of a laser tube was recorded in addition to that from the skin layer.

  9. Laser assisted deposition

    NASA Technical Reports Server (NTRS)

    Dutta, S.

    1983-01-01

    Applications of laser-based processing techniques to solar cell metallization are discussed. Laser-assisted thermal or photolytic maskless deposition from organometallic vapors or solutions may provide a viable alternative to photovoltaic metallization systems currently in use. High power, defocused excimer lasers may be used in conjunction with masks as an alternative to direct laser writing to provide higher throughput. Repeated pulsing with excimer lasers may eliminate the need for secondary plating techniques for metal film buildup. A comparison between the thermal and photochemical deposition processes is made.

  10. Excimer laser photorefractive surgery of the cornea

    NASA Astrophysics Data System (ADS)

    Gaster, Ronald N.

    1998-09-01

    The 193 nm argon fluoride (ArF) excimer laser can effectively be used to change the radius of curvature of the cornea and thus alter the refractive state of the eye. This change allows myopic (nearsighted) patients to see well with less dependence on glasses or contact lenses. The two major techniques of laser refractive surgery currently in effect in the United States are photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK). This paper will discuss these refractive cornea surgical techniques.

  11. High excimer-state emission of perylene bisimides and recognition of latent fingerprints.

    PubMed

    Wang, Ke-Rang; Yang, Zi-Bo; Li, Xiao-Liu

    2015-04-07

    High excimer-state emission in the H-type aggregate of a novel asymmetric perylene bisimide derivative, 6, with triethyleneglycol chains and lactose functionalization was achieved in water. Furthermore, its application for enhancing the visualization of transfer latent fingerprints from glass slides to the poly(vinylidene fluoride) (PVDF) membrane was explored, which showed clear images of the latent fingerprint in daylight and under 365 nm ultraviolet illumination. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Thermodynamic and Kinetic Behavior of the Polystyrene/Poly(vinyl methyl ether) Blend as Studied by Excimer Fluorescence.

    DTIC Science & Technology

    1986-01-02

    AD-A±63 895 THERMODYNAMIC AND KINETIC BEHAVIOR OF THE / POLYSTYRENE/POLY(YINYL METHYL E..(U) STANFORD UNIY CALIFDEPT OF CHEMICAL ENGINEERING C N...Polystyrene/Poly(vinyl methyl ether) Blend 7. DEcFRMN 81 toOR 30USptE8 00~ as Studied by Excimer Fluorescence 6 EFRIGOG EOTNME *AUTHOR() a. CONTRACT OR GRANT...werea fondoare ihemoriisof * ~ Ex e sp fluodecositionsdu to deud Gen e and hoog Pinus Florsneis shownhase migrationprocSECURITY CLASIFICTIO OFd

  13. New SPUDT cell structures.

    PubMed

    Martin, Guenter; Schmidt, Hagen; Wall, Bert

    2004-07-01

    The present paper describes single-phase unidirectional transducers (SPUDT) cells with all fingers wider than lambda/8 while maintaining the unidirectional effect. The first solution is related to a SPUDT consisting of lambda/4 and lambda/2 wide fingers arranged in two tracks. Each track has no significant unidirectional effect. Both tracks form a waveguide, and the waveguide coupling generates the interaction of the tracks. As a result of that interaction, a unidirectional effect arises as verified by experiment. This transducer type is called double-track (DT) SPUDT. A second solution is suggested that includes, in contrast to distributed acoustic reflection transducer (DART), electrode width control (EWC), and Hunsinger cells, SPUDT cell fingers with one and the same width only. Cell types with lambda/6, lambda/5, and lambda/3 wide fingers called uniform width electrode (UWE) cells are considered. One of these cell types, including exclusively lambda/5 wide fingers, is experimentally investigated and a unidirectional effect is found. Moreover, a filter example using the lambda/5 cell type has been designed for reducing SPUDT reflections. The echo suppression expected could be verified experimentally. No waveguide coupling is required for this cell type.

  14. Recombination between bacteriophage lambda and plasmid pBR322 in Escherichia coli.

    PubMed Central

    Pogue-Geile, K L; Dassarma, S; King, S R; Jaskunas, S R

    1980-01-01

    Recombinant lambda phages were isolated that resulted from recombination between the lambda genome and plasmid pBR322 in Escherichia coli, even though these deoxyribonucleic acids (DNAs) did not share extensive regions of homology. The characterization of these recombinant DNAs by heteroduplex analysis and restriction endonucleases is described. All but one of the recombinants appeared to have resulted from reciprocal recombination between a site on lambda DNA and a site on the plasmid. In general, there were two classes of recombinants. One class appeared to have resulted from recombination at the phage attachment site that probably resulted from lambda integration into secondary attachment sites on the plasmid. Seven different secondary attachment sites on pBR322 were found. The other class resulted from plasmid integration at other sites that were widely scattered on the lambda genome. For this second class of recombinants, more than one site on the plasmid could recombine with lambda DNA. Thus, the recombination did not appear to be site specific with respect to lambda or the plasmid. Possible mechanisms for generating these recombinants are discussed. Images PMID:6247334

  15. The risk of renal disease is increased in lambda myeloma with bone marrow amyloid deposits.

    PubMed

    Kozlowski, Piotr; Montgomery, Scott; Befekadu, Rahel; Hahn-Strömberg, Victoria

    2017-01-01

    Light chain amyloidosis (AL) is a rare deposition disease and is present in 10-15% of patients with myeloma (MM). In contrast to symptomatic AL in MM, presence of bone marrow (BM) amyloid deposits (AD) in MM is not connected to kidney damage. Renal AD but not BM-AD occur mostly in MM with lambda paraprotein (lambda MM). We investigated amyloid presence in BM clots taken at diagnosis in 84 patients with symptomatic MM and compared disease characteristics in MM with kappa paraprotein (kappa MM)/lambda MM with and without BM-AD. Lambda MM with BM-AD was compared with kappa MM without BM-AD, kappa MM with BM-AD, and lambda MM without BM-AD: lambda MM with BM-AD patients had a significantly higher mean creatinine level (4.23 mg/dL vs 1.69, 1.14, and 1.28 mg/dL, respectively) and a higher proportion presented with severe kidney failure (6/11 [55%] vs 6/32 [19%], 1/22 [5%], and 3/19 [16%], respectively). Proteinuria was more common in lambda MM with BM-AD patients compared with kappa MM without BM-AD patients (8/11 [73%] vs 5/32 [16%], respectively). Kidney damage was more common in lambda MM with BM-AD indicating presence of renal AD.

  16. Elevated carboxylesterase activity contributes to the lambda-cyhalothrin insensitivity in quercetin fed Helicoverpa armigera (Hübner).

    PubMed

    Chen, Chengyu; Liu, Ying; Shi, Xueyan; Desneux, Nicolas; Han, Peng; Gao, Xiwu

    2017-01-01

    Quercetin as one of the key plant secondary metabolite flavonol is ubiquitous in terrestrial plants. In this study, the decrease in sensitivity to lambda-cyhalothrin was observed in quercetin-fed Helicoverpa armigera larvae. In order to figure out the mechanisms underlying the decreased sensitivity of H. armigera larvae to lambda-cyhalothrin by quercetin induction, the changes in carboxylesterase activity and in-vitro hydrolytic metabolic capacity to lambda-cyhalothrin were examined. The LC50 value of quercetin-fed H. armigera larvae to lambda-cyhalothrin showed 2.41-fold higher than that of the control. S, S, S-Tributyl phosphorotrithioate (DEF) treatment showed a synergism effect on lambda-cyhalothrin toxicity to quercetin-fed H. armigera. Moreover, the activity of carboxylesterase was significantly higher in quercetin-fed H. armigera larvae after fed on quercetin for 48 h. The in-vitro hydrolytic metabolic capacity to lambda-cyhalothrin in quercetin-fed H. armigera larvae midgut was 289.82 nmol 3-PBA/mg protein/min, which is significant higher than that in the control group (149.60 nmol 3-PBA/mg protein/min). The elevated CarE enzyme activity and corresponding increased hydrolytic metabolic capacity to lambda-cyhalothrin in quercetin-fed H. armigera contributed to the enhanced tolerance to lambda-cyhalothrin.

  17. Elevated carboxylesterase activity contributes to the lambda-cyhalothrin insensitivity in quercetin fed Helicoverpa armigera (Hübner)

    PubMed Central

    Chen, Chengyu; Liu, Ying; Desneux, Nicolas; Han, Peng; Gao, Xiwu

    2017-01-01

    Quercetin as one of the key plant secondary metabolite flavonol is ubiquitous in terrestrial plants. In this study, the decrease in sensitivity to lambda-cyhalothrin was observed in quercetin-fed Helicoverpa armigera larvae. In order to figure out the mechanisms underlying the decreased sensitivity of H. armigera larvae to lambda-cyhalothrin by quercetin induction, the changes in carboxylesterase activity and in-vitro hydrolytic metabolic capacity to lambda-cyhalothrin were examined. The LC50 value of quercetin-fed H. armigera larvae to lambda-cyhalothrin showed 2.41-fold higher than that of the control. S, S, S-Tributyl phosphorotrithioate (DEF) treatment showed a synergism effect on lambda-cyhalothrin toxicity to quercetin-fed H. armigera. Moreover, the activity of carboxylesterase was significantly higher in quercetin-fed H. armigera larvae after fed on quercetin for 48 h. The in-vitro hydrolytic metabolic capacity to lambda-cyhalothrin in quercetin-fed H. armigera larvae midgut was 289.82 nmol 3-PBA/mg protein/min, which is significant higher than that in the control group (149.60 nmol 3-PBA/mg protein/min). The elevated CarE enzyme activity and corresponding increased hydrolytic metabolic capacity to lambda-cyhalothrin in quercetin-fed H. armigera contributed to the enhanced tolerance to lambda-cyhalothrin. PMID:28817718

  18. Quadrupole deformation ({beta},{gamma}) of light {Lambda} hypernuclei in a constrained relativistic mean field model: Shape evolution and shape polarization effect of the {Lambda} hyperon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu Bingnan; Zhao Enguang; Center of Theoretical Nuclear Physics, National Laboratory of Heavy Ion Accelerator, Lanzhou 730000

    2011-07-15

    The shapes of light normal nuclei and {Lambda} hypernuclei are investigated in the ({beta},{gamma}) deformation plane by using a newly developed constrained relativistic mean field (RMF) model. As examples, the results of some C, Mg, and Si nuclei are presented and discussed in details. We found that for normal nuclei the present RMF calculations and previous Skyrme-Hartree-Fock models predict similar trends of the shape evolution with the neutron number increasing. But some quantitative aspects from these two approaches, such as the depth of the minimum and the softness in the {gamma} direction, differ a lot for several nuclei. For {Lambda}more » hypernuclei, in most cases, the addition of a {Lambda} hyperon alters slightly the location of the ground state minimum toward the direction of smaller {beta} and softer {gamma} in the potential energy surface E{approx}({beta},{gamma}). There are three exceptions, namely, {sub {Lambda}}{sup 13}C, {sub {Lambda}}{sup 23}C, and {sub {Lambda}}{sup 31}Si in which the polarization effect of the additional {Lambda} is so strong that the shapes of these three hypernuclei are drastically different from their corresponding core nuclei.« less

  19. Serum Free Light Chains in Neoplastic Monoclonal Gammopathies: Relative Under-Detection of Lambda Dominant Kappa/Lambda Ratio, and Underproduction of Free Lambda Light Chains, as Compared to Kappa Light Chains, in Patients With Neoplastic Monoclonal Gammopathies

    PubMed Central

    Lee, Won Sok; Singh, Gurmukh

    2018-01-01

    Background Quantitative evaluation of serum free light chains is recommended for the work up of monoclonal gammopathies. Immunoglobulin light chains are generally produced in excess of heavy chains. In patients with monoclonal gammopathy, κ/λ ratio is abnormal less frequently with lambda chain lesions. This study was undertaken to ascertain if the levels of overproduction of the two light chain types and their detection rates are different in patients with neoplastic monoclonal gammopathies. Methods Results of serum protein electrophoresis (SPEP), serum protein immunofixation electrophoresis (SIFE), urine protein electrophoresis (UPEP), urine protein immunofixation electrophoresis (UIFE), and serum free light chain assay (SFLCA) in patients with monoclonal gammopathies were examined retrospectively. Results The κ/λ ratios were appropriately abnormal more often in kappa chain lesions. Ratios of κ/λ were normal in about 25% of patients with lambda chain lesions in whom free homogenous lambda light chains were detectable in urine. An illustrative case suggests underproduction of free lambda light chains, in some instances. Conclusions The lower prevalence of lambda dominant κ/λ ratio in lesions with lambda light chains is estimated to be due to relative under-detection of lambda dominant κ/λ ratio in about 25% of the patients and because lambda chains are not produced in as much excess of heavy chains as are kappa chains, in about 5% of the patients. The results question the medical necessity and clinical usefulness of the serum free light chain assay. UPEP/UIFE is under-utilized. PMID:29904440

  20. Antitumor activity of type I and type III interferons in BNL hepatoma model.

    PubMed

    Abushahba, Walid; Balan, Murugabaskar; Castaneda, Ismael; Yuan, Yao; Reuhl, Kenneth; Raveche, Elizabeth; de la Torre, Andrew; Lasfar, Ahmed; Kotenko, Sergei V

    2010-07-01

    Hepatocellular carcinoma (HCC) occurs most commonly secondary to cirrhosis due to chronic hepatitis C or B virus (HCV/HBV) infections. Type I interferon (IFN-alpha) treatment of chronic HCV/HBV infections reduces the incidence of HCC in cirrhotic patients. However, IFN-alpha toxicity limits its tolerability and efficacy highlighting a need for better therapeutic treatments. A recently discovered type III IFN (IFN-lambda) has been shown to possess antiviral properties against HCV and HBV in vitro. In phase I clinical trials, IFN-lambda treatment did not cause significant adverse reactions. Using a gene therapy approach, we compared the antitumor properties of IFN-alpha and IFN-lambda in a transplantable hepatoma model of HCC. BALB/c mice were inoculated with syngeneic BNL hepatoma cells, or BNL cells expressing IFN-lambda (BNL.IFN-lambda cells) or IFN-alpha (BNL.IFN-alpha cells). Despite the lack of antiproliferative activity of IFNs on BNL cells, both BNL.IFN-lambda and BNL.IFN-alpha cells displayed retarded growth kinetics in vivo. Depletion of NK cells from splenocytes inhibited splenocyte-mediated cytotoxicity, demonstrating that NK cells play a role in IFN-induced antitumor responses. However, isolated NK cells did not respond directly to IFN-lambda. There was also a marked NK cell infiltration in IFN-lambda producing tumors. In addition, IFN-lambda and, to a lesser extent, IFN-alpha enhanced immunocytotoxicity of splenocytes primed with irradiated BNL cells. Splenocyte cytotoxicity against BNL cells was dependent on IL-12 and IFN-gamma, and mediated by dendritic cells. In contrast to NK cells, isolated from spleen CD11c+ and mPDCA+ dendritic cells responded directly to IFN-lambda. The antitumor activities of IFN-lambda against hepatoma, in combination with HCV and HBV antiviral activities warrant further investigation into the clinical use of IFN-lambda to prevent HCC in HCV/HBV-infected cirrhotic patients, as well as to treat liver cancer.

  1. A randomized, controlled study of peginterferon lambda-1a/ribavirin ± daclatasvir for hepatitis C virus genotype 2 or 3.

    PubMed

    Foster, Graham R; Chayama, Kazuaki; Chuang, Wan-Long; Fainboim, Hugo; Farkkila, Martti; Gadano, Adrian; Gaeta, Giovanni B; Hézode, Christophe; Inada, Yukiko; Heo, Jeong; Kumada, Hiromitsu; Lu, Sheng-Nan; Marcellin, Patrick; Moreno, Christophe; Roberts, Stuart K; Strasser, Simone I; Thompson, Alexander J; Toyota, Joji; Paik, Seung Woon; Vierling, John M; Zignego, Anna L; Cohen, David; McPhee, Fiona; Wind-Rotolo, Megan; Srinivasan, Subasree; Hruska, Matthew; Myler, Heather; Portsmouth, Simon D

    2016-01-01

    Peginterferon Lambda was being developed as an alternative to alfa interferon for the treatment of chronic hepatitis C virus (HCV) infection. We compared peginterferon Lambda-1a plus ribavirin (Lambda/RBV) and Lambda/RBV plus daclatasvir (DCV; pangenotypic NS5A inhibitor) with peginterferon alfa-2a plus RBV (alfa/RBV) in treatment-naive patients with HCV genotype 2 or 3 infection. In this multicenter, double-blind, phase 3 randomized controlled trial, patients were assigned 2:2:1 to receive 24 weeks of Lambda/RBV, 12 weeks of Lambda/RBV + DCV, or 24 weeks of alfa/RBV. The primary outcome measure was sustained virologic response at post-treatment Week 12 (SVR12). Overall, 874 patients were treated: Lambda/RBV, n = 353; Lambda/RBV + DCV, n = 349; alfa/RBV, n = 172. Patients were 65 % white and 33 % Asian, 57 % male, with a mean age of 47 years; 52 % were infected with genotype 2 (6 % cirrhotic) and 48 % with genotype 3 (9 % cirrhotic). In the Lambda/RBV + DCV group, 83 % (95 % confidence interval [CI] 78.5, 86.5) achieved SVR12 (90 % genotype 2, 75 % genotype 3) whereas SVR12 was achieved by 68 % (95 % CI 63.1, 72.9) with Lambda/RBV (72 % genotype 2, 64 % genotype 3) and 73 % (95 % CI 66.6, 79.9) with peginterferon alfa/RBV (74 % genotype 2, 73 % genotype 3). Lambda/RBV + DCV was associated with lower incidences of flu-like symptoms, hematological abnormalities, and discontinuations due to adverse events compared with alfa/RBV. The 12-week regimen of Lambda/RBV + DCV was superior to peginterferon alfa/RBV in the combined population of treatment-naive patients with genotype 2 or 3 infection, with an improved tolerability and safety profile compared with alfa/RBV.

  2. Dynamic processes in Be star atmospheres. 2: He I 2P-nD line formation in lambda Eridani (outburst)

    NASA Technical Reports Server (NTRS)

    Smith, Myron A.; Hubeny, Ivan; Lanz, Thierry; Meylan, Thomas

    1994-01-01

    The He I lambda 6678 line of early Be stars generally shows violet (V) and red (R) emission whenever hydrogen alpha emission is present, but its use as a diagnostic has been handicapped by a poor understanding of the processes that drive it into emission. In an attempt to address this problem we obtained three series of eschelle spectra of the first two members of the singlet and triplet 2P-nD series of lambda Eri (B2e) during 1992 November 3-5 at Kitt Peak. During these observations lambda 6678 showed substantial emission variability in both the wings and central profile, providing an opportunity to compare its behavior with that of the lambda 4922, lambda 5876, and lambda 4471 lines. We found that the responses of the lines were different in several respects. Whereas the emissions in the V wings of all four lines scaled together, the R wing of the lambda 4922 line invariably responded with increased absorption whenever the R wing of lambda 6678 line showed increased emission. These same trends occurred within the central photospheric profiles. The R-wing behavior shows that much, but not all of the emission in lambda 6678 is caused by matter projected against the stellar disk. The excitation temperatures of the neighboring 2(sup 1) P transitions, lambda 6678 and lambda 4922 must be greater than and less than the photospheric continuum temperature, respectively. We have investigated departures from local thermodynamic equilibrium (LTE) for the He I spectrum in a variety of ad hoc, perturbed model atmospheres. We have found only one way to cause the source function of lambda 6678 to increase so strongly, namely, by increasing the atmospheric temperature in the line formation region to 30,000 - 40,000 K. This effect was discovered by Auer and Mihalas for O3-O4 atmospheric models, but it has not been applied to active B stars. Our models suggest that lambda 6678 emission in Be stars can be used as a sensitive monitor of localized hot spots on these stars' surfaces. The energies involved in heating the active portions of the atmosphere are too high to be produced by gravitational infall. This leaves magnetically induced flares among the few known processes on the surfaces of stars capable of sustaining this energy level.

  3. [Excitation transfer between high-lying states in K2 in collisions with ground state K and H2 molecules].

    PubMed

    Shen, Xiao-Yan; Liu, Jing; Dai, Kang; Shen, Yi-Fan

    2010-02-01

    Pure potassium vapor or K-H2 mixture was irradiated in a glass fluorescence cell with pulses of 710 nm radiation from an OPO laser, populating K2 (1lambda(g)) state by two-photon absorption. Cross sections for 1lambda(g)-3lambda(g) transfer in K2 were determined using methods of molecular fluorescence. During the experiments with pure K vapor, the cell temperature was varied between 553 and 603 K. The K number density was determined spectroscopically by the white-light absorption measurement in the blue wing of the self-broadened resonance D2 line. The resulting fluorescence included a direct component emitted in the decay of the optically excitation and a sensitized component arising from the collisionally populated state. The decay signal of time-resolved fluorescence from1lambda(g) -->1 1sigma(u)+ transition was monitored. It was seen that just after the laser pulse the fluorescence of the photoexcited level decreased exponentially. The effective lifetimes of the 1lambda(g) state can be resolved. The plot of reciprocal of effective lifetimes of the 1lambda(g) state against K densities yielded the slope that indicated the total cross section for deactivation and the intercept that provided the radiative lifetime of the state. The radiative lifetime (20 +/- 2) ns was obtained. The cross section for deactivation of the K2(1lambda(g)) molecules by collisions with K is (2.5 +/- 0.3) x 10(-14) cm2. The time-resolved intensities of the K23lambda(g) --> 1 3sigma(u)+ (484 nm) line were measured. The radiative lifetime (16.0 +/- 3.2) ns and the total cross section (2.5 +/- 0.6) x 10(-14) cm2 for deactivation of the K2 (3lambda(g)) state can also be determined through the analogous procedure. The time-integrated intensities of 1lambda(g) --> 1 1sigma(u)+ and 3lambda(g) --> 1 3sigma(u)+ transitions were measured. The cross section (1.1 +/- 0.3) x10(-14) cm2 was obtained for K2 (1lambda(g))+ K --> K2 (3lambda(g)) + K collisions. During the experiments with K-H2 mixture, the cell temperature was kept constant at 553 K. The H2 pressure was varied between 40 and 400 Pa. The effects of K2-K collisions could not be neglected. These effects were subtracted out using the results of the pure K experiments. The cross section (2.7 +/- 1.1) x 10(-15) cm2 was obtained for K2 (1lambda(g)) + H2 --> K2 (3lambda(g))+H2 collisions. The cross section is (6.8 +/- 2.7) x 10(-15) cm2 for K2 (3lambda(g)) + H2 --> states out of K2 (3lambda(g)) + H2 collisions.

  4. Photochemical sensitization by azathioprine and its metabolites. Part 3. A direct EPR and spin-trapping study of light-induced free radicals from 6-mercaptopurine and its oxidation products.

    PubMed

    Moore, D E; Sik, R H; Bilski, P; Chignell, C F; Reszka, K J

    1994-12-01

    Sunlight has been implicated in the high incidence of skin cancer found in patients receiving 6-mercaptopurine (PSH) in the form of its pro-drug azathioprine. In this study we have used EPR spectroscopy in conjunction with the spin-trapping technique to determine whether PSH and its metabolic or photochemical oxidation products generate highly reactive free radicals upon UV irradiation. When an aqueous anaerobic solution (pH 5 or 9) of PSH (pKa = 7.7) and either 2-methyl-2-nitrosopropane (MNP) or nitromethane (NM) were irradiated (lambda > 300 nm) with a Xe arc lamp, the corresponding purine-6-thiyl (PS.) radical adduct and the reduced form of the spin trap (MNP/H. or CH3NO2.-) were observed. However, no radical adducts were detected when PSH and 5,5-dimethyl-1-pyrroline-N-oxide (DMPO) were irradiated (lambda = 320 nm) in oxygen-free buffer. These findings suggest that PSH does not photoionize but that instead MNP and NM are reduced by direct electron transfer from excited state PSH, 1.3(PSH)*. In aerobic solution, oxygen can act as an electron acceptor and the O2.- and PS. radicals are formed and trapped by DMPO. 6-Mercaptopurine did photoionize when irradiated with a Nd:YAG laser at 355 nm as evidenced by the appearance of the DMPO/H.(eq- + H+) adduct, which decreased in intensity in the presence of N2O. 1.3(6-Mercaptopurine)* oxidized ascorbate, formate and reduced glutathione to the corresponding ascorbyl, CO2.- or glutathiyl radicals. The photochemical behavior of 6-thioxanthine and 6-thiouric acid was similar to PSH. However, the excited states of these metabolic oxidation products exhibited stronger reducing properties than 1.3(PSH)*.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Excimer laser annealing of NiTi shape memory alloy thin film

    NASA Astrophysics Data System (ADS)

    Xie, Qiong; Huang, Weimin; Hong, Ming Hui; Song, Wendong; Chong, Tow Chong

    2003-02-01

    NiTi Shape Memory Alloy (SMA) is with great potential for actuation in microsystems. It is particularly suitable for medical applications due to its excellent biocompatibility. In MEMS, local annealing of SMA is required in the process of fabrication. In this paper, local annealing of Ni52Ti48 SMA with excimer laser is proposed for the first time. The Ni52Ti48 thin film in a thickness of 5 μm was deposited on Si (100) wafer by sputtering at room temperature. After that, the thin film was annealed by excimer laser (248nm KrF laser) for the first time. Field-Emission Scanning Electron Microscopy (FESEM) and Atomic Force Microscopy (AFM) were used to characterize the surface profile of the deposited film after laser annealing. The phase transformation was measured by Differential Scanning Calorimeter (DSC) test. It is concluded that NiTi film sputtering on Si(100) substrate at room temperature possesses phase transformation after local laser annealing but with cracks.

  6. Optical and Thermal Stability of Oligofluorene/Rubber Luminescent Blend.

    PubMed

    Barbosa, Camila G; Faez, Roselena; Péres, Laura O

    2016-09-01

    This paper proposes to obtain homogeneous and stable blends of oligo(9,9-dioctylfluorene)-co-phenylene (OF), a conjugated oligomer with strong tendency of formation of excimers in the solid state, and nitrile rubber (NBR). This rubber protection reduces the formation of polymer excimers in the films. The fluorene oligomer was synthesized via Suzuki reaction and incorporated in the nitrile rubber. The films were formed by spin coating and casting techniques on the proportions of 1, 5, 10, 20 and 50 % (w/w) of OF in the nitrile rubber (NBR). The structural, optical and thermal properties of the films were evaluated with infrared, UV-Vis, fluorescence and thermogravimetry, respectively. The nitrile rubber proved to be essential for the preparation of homogeneous and stable films, since it was not possible to obtain films with only fluorene using the above-mentioned techniques. Furthermore, luminescent properties of OF are unchanged and the excimers formation in the solid state decrease suggesting the efficiency of nitrile rubber as the matrix for making films.

  7. Excimer laser annealing to fabricate low cost solar cells

    NASA Technical Reports Server (NTRS)

    1984-01-01

    The objective is to show whether or not pulsed excimer laser annealing (PELA) of ion-implanted junctions is a cost effective replacement for diffused junctions in fabricating crystalline silicon solar cells. The preliminary economic analysis completed shows that the use of PELA to fabricate both the front junction and back surface field (BSF) would cost approximately 35 cents per peak watt (Wp), compared to a cost of 15 cents/Wp for diffusion, aluminum BSF and an extra cleaning step in the baseline process. The cost advantage of the PELA process depends on improving the average cell efficiency from 14% to 16%, which would lower the overall cost of the module by about 15 cents/Wp. An optimized PELA process compatible with commercial production is to be developed, and increased cell efficiency with sufficient product for adequate statistical analysis demonstrated. An excimer laser annealing station was set-up and made operational. The first experiment used 248 nm radiation to anneal phosphorus implants in polished and texture-etched silicon.

  8. Method for forming silicon on a glass substrate

    DOEpatents

    McCarthy, Anthony M.

    1995-01-01

    A method by which single-crystal silicon microelectronics may be fabricated on glass substrates at unconventionally low temperatures. This is achieved by fabricating a thin film of silicon on glass and subsequently forming the doped components by a short wavelength (excimer) laser doping procedure and conventional patterning techniques. This method may include introducing a heavily boron doped etch stop layer on a silicon wafer using an excimer laser, which permits good control of the etch stop layer removal process. This method additionally includes dramatically reducing the remaining surface roughness of the silicon thin films after etching in the fabrication of silicon on insulator wafers by scanning an excimer laser across the surface of the silicon thin film causing surface melting, whereby the surface tension of the melt causes smoothing of the surface during recrystallization. Applications for this method include those requiring a transparent or insulating substrate, such as display manufacturing. Other applications include sensors, actuators, optoelectronics, radiation hard and high temperature electronics.

  9. Method for forming silicon on a glass substrate

    DOEpatents

    McCarthy, A.M.

    1995-03-07

    A method by which single-crystal silicon microelectronics may be fabricated on glass substrates at unconventionally low temperatures. This is achieved by fabricating a thin film of silicon on glass and subsequently forming the doped components by a short wavelength (excimer) laser doping procedure and conventional patterning techniques. This method may include introducing a heavily boron doped etch stop layer on a silicon wafer using an excimer laser, which permits good control of the etch stop layer removal process. This method additionally includes dramatically reducing the remaining surface roughness of the silicon thin films after etching in the fabrication of silicon on insulator wafers by scanning an excimer laser across the surface of the silicon thin film causing surface melting, whereby the surface tension of the melt causes smoothing of the surface during recrystallization. Applications for this method include those requiring a transparent or insulating substrate, such as display manufacturing. Other applications include sensors, actuators, optoelectronics, radiation hard and high temperature electronics. 15 figs.

  10. Determination of excimer laser ablation rate of the human cornea using in vivo Scheimpflug videography.

    PubMed

    Huebscher, H J; Genth, U; Seiler, T

    1996-01-01

    To determine in vivo the amount of human corneal tissue removed by each excimer laser pulse, the so-called ablation rate, during photorefractive keratectomy (PRK). There is confusion in the literature because the experimentally determined ablation rate of 0.4 to 0.5 microns per pulse differs from the nominal ablation rate of 0.23 to 0.3 microns per pulse, which is the value used in clinical procedures. Eleven eyes of 11 patients were treated with PRK for correction of myopia. The corneal curvature was determined by Scheimpflug videography before and immediately after surgery. Starting from this curvature change, the authors calculated the real ablation rate. The real ablation rate is coincident with the nominal ablation rate and differs significantly from the ablation rate derived from deep keratectomy experiments. The outer layers of the cornea show significantly different ablation behavior than the deeper stroma. This information has clinical relevance for the predictability of intrastromal excimer laser procedures.

  11. Micro flow-through PCR in a PMMA chip fabricated by KrF excimer laser.

    PubMed

    Yao, Liying; Liu, Baoan; Chen, Tao; Liu, Shibing; Zuo, Tiechuan

    2005-09-01

    As the third PCR technology, micro flow-through PCR chip can amplify DNA specifically in an exponential fashion in vitro. Nowadays many academies in the world have successfully amplified DNA using their own-made flow-through PCR chip. In this paper, the ablation principle of PMMA at 248 nm excimer laser was studied, then a PMMA based flow-through PCR chip with 20 cycles was fabricated by excimer laser at 19 kv and 18 mm/min. The chip was bonded together with another cover chip at 105( composite function)C, 160 N and 20 minutes. In the end, it was integrated with electrical thermal thin films and Pt 100 temperature sensors. The temperature controllers was built standard PID digital temperature controller, the temperature control precision was +/- 0.2( composite function)C. The temperature grads between the three temperature zones were 16.5 and 22.2( composite function)C respectively, the gaps between the temperature zones could realize heat insulation.

  12. Effects of XeCl excimer lasers and fluoride application on artificial caries-like lesions

    NASA Astrophysics Data System (ADS)

    Wilder-Smith, Petra B. B.; Phan, T.; Liaw, Lih-Huei L.; Berns, Michael W.

    1994-09-01

    In this study the affects of a pulsed excimer laser emitting at 308 nm (XeCl) on enamel susceptibility to artificial caries-like lesions were investigated. Additional effects of fluoride (F) application were also studied and SEC examinations performed. Sixty-four extracted human molar teeth were coated with acid resistant varnish leaving four windows, then sectioned, leaving one window on each tooth quarter. The windows were treated in one of the following ways: untreated (control), or lased, or exposed to 4 min. APF (1.23% F) before lasing, or exposed to 4 min. APF (1.23% F) after lasing. After lasing, microhardness profiles were obtained and SEM was performed. Caries resistance was generally increased at moderate fluences. F application combined with lasing enhanced caries resistance at some parameters. SEM showed effects ranging from minimal to localized effects to extended glazing. Pulsed excimer laser irradiation, especially combined with topical F application can inhibit development of artificial caries-like lesions.

  13. Magnetic penetration depth of YBa2Cu3O(7-delta) thin films determined by the power transmission method

    NASA Technical Reports Server (NTRS)

    Heinen, Vernon O.; Miranda, Felix A.; Bhasin, Kul B.

    1992-01-01

    A power transmission measurement technique was used to determine the magnetic penetration depth (lambda) of YBa2Cu3O(7-delta) superconducting thin films on LaAlO3 within the 26.5 to 40.0 GHz frequency range, and at temperatures from 20 to 300 K. Values of lambda ranging from 1100 to 2500 A were obtained at low temperatures. The anisotropy of lambda was determined from measurements of c-axis and a-axis oriented films. An estimate of the intrinsic value of lambda of 90 +/- 30 nm was obtained from the dependence of lambda on film thickness. The advantage of this technique is that it allows lambda to be determined nondestructively.

  14. Measurement of the Branching Ratio Lambda_c+ -> p pi+ pi- (in Spanish)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lopez-Hinojosa, Guillermo; /San Luis Potosi U.

    2008-03-01

    The confirmation of the Cabibbo-suppressed charm baryon decay mode {Lambda}{sub c}{sup +} {yields} p{pi}{sup +}{pi}{sup -} is reported. All data analyzed are from SELEX, a fixed target experiment at Fermilab that took data during 1996 and 1997, mainly with a 600 GeV/c {Sigma}{sup -} beam. The branching ratio of the Cabibbo-suppressed decay mode {Lambda}{sub c}{sup +} {yields} p{pi}{sup +}{pi}{sup -} relative to the Cabibbo-favored mode {Lambda}{sub c}{sup +} {yields} pK{sup -}{pi}{sup +} is measured to be: {Gamma}({Lambda}{sub c}{sup +} {yields} p{pi}{sup +}{pi}{sup -})/{Gamma}({Lambda}{sub c}{sup +} {yields} pK{sup -}{pi}{sup +}) = 0.103 {+-} 0.022.

  15. 49 CFR 393.24 - Requirements for head lamps, auxiliary driving lamps and front fog lamps.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 5 2012-10-01 2012-10-01 false Requirements for head lamps, auxiliary driving lamps and front fog lamps. 393.24 Section 393.24 Transportation Other Regulations Relating to... MOTOR CARRIER SAFETY REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective...

  16. 49 CFR 393.24 - Requirements for head lamps, auxiliary driving lamps and front fog lamps.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 5 2014-10-01 2014-10-01 false Requirements for head lamps, auxiliary driving lamps and front fog lamps. 393.24 Section 393.24 Transportation Other Regulations Relating to... MOTOR CARRIER SAFETY REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective...

  17. 49 CFR 393.24 - Requirements for head lamps, auxiliary driving lamps and front fog lamps.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 5 2013-10-01 2013-10-01 false Requirements for head lamps, auxiliary driving lamps and front fog lamps. 393.24 Section 393.24 Transportation Other Regulations Relating to... MOTOR CARRIER SAFETY REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective...

  18. Cationic Organochalcogen with Monomer/Excimer Emissions for Dual-Color Live Cell Imaging and Cell Damage Diagnosis.

    PubMed

    Chao, Xi-Juan; Wang, Kang-Nan; Sun, Li-Li; Cao, Qian; Ke, Zhuo-Feng; Cao, Du-Xia; Mao, Zong-Wan

    2018-04-25

    Studies on the development of fluorescent organic molecules with different emission colors for imaging of organelles and their biomedical application are gaining lots of focus recently. Here, we report two cationic organochalcogens 1 and 2, both of which exhibit very weak green emission (Φ 1 = 0.12%; Φ 2 = 0.09%) in dilute solution as monomers, but remarkably enhanced green emission upon interaction with nucleic acids and large red-shifted emission in aggregate state by the formation of excimers at high concentration. More interestingly, the monomer emission and excimer-like emission can be used for dual color imaging of different organelles. Upon passively diffusing into cells, both probes selectively stain nucleoli with strong green emission upon 488 nm excitation, whereas upon 405 nm excitation, a completely different stain pattern by staining lysosomes (for 1) or mitochondria (for 2) with distinct red emission is observed because of the highly concentrated accumulation in these organelles. Studies on the mechanism of the accumulation in lysosomes (for 1) or mitochondria (for 2) found that the accumulations of the probes are dependent on the membrane permeabilization, which make the probes have great potential in diagnosing cell damage by sensing lysosomal or mitochondrial membrane permeabilization. The study is demonstrative, for the first time, of two cationic molecules for dual-color imaging nucleoli and lysosomes (1)/mitochondria (2) simultaneously in live cell based on monomer and excimer-like emission, respectively, and more importantly, for diagnosing cell damage.

  19. A design of energy detector for ArF excimer lasers

    NASA Astrophysics Data System (ADS)

    Feng, Zebin; Han, Xiaoquan; Zhou, Yi; Bai, Lujun

    2017-08-01

    ArF excimer lasers with short wavelength and high photon energy are widely applied in the field of integrated circuit lithography, material processing, laser medicine, and so on. Excimer laser single pulse energy is a very important parameter in the application. In order to detect the single pulse energy on-line, one energy detector based on photodiode was designed. The signal processing circuit connected to the photodiode was designed so that the signal obtained by the photodiode was amplified and the pulse width was broadened. The amplified signal was acquired by a data acquisition card and stored in the computer for subsequent data processing. The peak of the pulse signal is used to characterize the single pulse energy of ArF excimer laser. In every condition of deferent pulse energy value levels, a series of data about laser pulses energy were acquired synchronously using the Ophir energy meter and the energy detector. A data set about the relationship between laser pulse energy and the peak of the pulse signal was acquired. Then, by using the data acquired, a model characterizing the functional relationship between the energy value and the peak value of the pulse was trained based on an algorithm of machine learning, Support Vector Regression (SVR). By using the model, the energy value can be obtained directly from the energy detector designed in this project. The result shows that the relative error between the energy obtained by the energy detector and by the Ophir energy meter is less than 2%.

  20. Endothelial reaction to perforating and non-perforating excimer laser excisions in rabbits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koch, J.W.; Lang, G.K.; Naumann, G.O.

    1991-05-01

    With an ArF excimer laser (193 nm, 750 mJ/cm2, 20 Hz) and a special slit-mask system, perforating and non-perforating linear keratectomies were performed in 55 rabbit corneas with a follow-up from 1 hour to 6 months. Varying the pulse number according to ablation rate (0.8 micron/pulse) and corneal thickness, four linear radial excisions (3 mm length, 70 microns width) of increasing depth (70%, 80%, 90%, 100% perforation) were produced. The corneas were processed for light microscopy, scanning and transmission electron microscopy, and vital staining of the endothelium. Except for mild cell contact alterations and discrete single cell damage in themore » 90% deep excisions, no endothelial damage could be detected after non-perforating keratectomies. Minute (less than 20 microns) and small (20 to 100 microns maximal diameter) perforations induced cell enlargement, formation of pseudopodia, rosette-like figures, multi-nucleated giant cells, and ultimately uniform reformation of the cell pattern (1 hour to 7 days postoperatively). Larger excimer laser defects of Descemet's membrane (greater than 100 microns) were overgrown by dedifferentiated endothelial cells producing a new PAS-positive basement membrane. Vital staining revealed the complete and stable reorganization of the endothelium over these lesions within 6 months. The authors observations are similar to those reported on the endothelial repair process following other surgical manipulations (knife incisions, direct Nd:YAG-laser trauma) and support the applicability of excimer lasers for corneal trephination in patients.« less

  1. LASIK for myopia and astigmatism using the SCHWIND AMARIS excimer laser: an international multicenter trial.

    PubMed

    Arbelaez, Maria Clara; Aslanides, Ioannis M; Barraquer, Carmen; Carones, Francesco; Feuermannova, Alena; Neuhann, Tobias; Rozsival, Pavel

    2010-02-01

    To assess the efficacy, predictability, and safety of LASIK for the surgical correction of low to moderate myopia with astigmatism using the SCHWIND AMARIS excimer laser. Six international study sites enrolled 358 eyes with a manifest refraction spherical equivalent (MRSE) from -0.50 to -7.38 diopters (D) (mean sphere: -3.13+/-1.58 D) with up to -5.00 D of astigmatism (mean: -0.69+/-0.67 D). All eyes underwent treatment with the nonwavefront-guided aspheric algorithm of the SCHWIND AMARIS excimer laser. All eyes were targeted for emmetropia. Refractive outcomes and corneal higher order aberrations were analyzed pre- and postoperatively. Visual quality was assessed using photopic and mesopic contrast sensitivity. Six-month postoperative outcomes are reported. At 6 months postoperative, the MRSE for all eyes was -0.21+/-0.20 D, and 96% (343/358) of eyes had MRSE within +/-0.50 D. Uncorrected visual acuity was 20/20 or better in 98% (351/358) of eyes, and no eyes lost 2 or more lines of best spectacle-corrected visual acuity. The total corneal higher order aberrations root-mean-square increased by 0.09 microm, spherical aberration increased by 0.08 microm, and coma increased by 0.04 microm postoperatively. Photopic and mesopic contrast sensitivity did not change 6 months postoperatively. Treatment of myopia with astigmatism using the SCHWIND AMARIS excimer laser is safe, efficacious, predictable, and maintains visual quality.

  2. 10 CFR 429.27 - General service fluorescent lamps, general service incandescent lamps, and incandescent reflector...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false General service fluorescent lamps, general service incandescent lamps, and incandescent reflector lamps. 429.27 Section 429.27 Energy DEPARTMENT OF ENERGY ENERGY... EQUIPMENT Certification § 429.27 General service fluorescent lamps, general service incandescent lamps, and...

  3. 10 CFR 429.27 - General service fluorescent lamps, general service incandescent lamps, and incandescent reflector...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false General service fluorescent lamps, general service incandescent lamps, and incandescent reflector lamps. 429.27 Section 429.27 Energy DEPARTMENT OF ENERGY ENERGY... EQUIPMENT Certification § 429.27 General service fluorescent lamps, general service incandescent lamps, and...

  4. 10 CFR 429.27 - General service fluorescent lamps, general service incandescent lamps, and incandescent reflector...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false General service fluorescent lamps, general service incandescent lamps, and incandescent reflector lamps. 429.27 Section 429.27 Energy DEPARTMENT OF ENERGY ENERGY... EQUIPMENT Certification § 429.27 General service fluorescent lamps, general service incandescent lamps, and...

  5. Autofluorescence spectroscopy of oral mucosa

    NASA Astrophysics Data System (ADS)

    Majumdar, S. K.; Uppal, A.; Gupta, P. K.

    1998-06-01

    We report the results of an in-vitro study on autofluorescence from pathologically characterized normal and malignant squamous tissues from the oral cavity. The study involved biopsy samples from 47 patients with oral cancer of which 11 patients had cancer of tongue, 17 of buccal mucosa and 19 of alveolus. The results of excitation and emission spectroscopy at several wavelengths (280 nm less than or equal to (lambda) exless than or equal to 460 nm; 340 nm less than or equal to (lambda) em less than or equal to 520 nm) showed that at (lambda) ex equals 337 nm and 400 nm the mean value for the spectrally integrated fluorescence intensity [(Sigma) (lambda ) IF((lambda) )] from the normal tissue sites was about a factor of 2 larger than that from the malignant tissue sites. At other excitation wavelengths the difference in (Sigma) (lambda ) IF((lambda) ) was not statistically significant. Similarly, for (lambda) em equals 390 nm and 460 nm, the intensity of the 340 nm band of the excitation spectra from normal tissues was observed to be a factor of 2 larger than that from malignant tissues. Analysis of these results suggests that NADH concentration is higher in normal oral tissues compared to the malignant. This contrasts with our earlier observation of an reduced NADH concentration in normal sites of breast tissues vis a vis malignant sites. For the 337 nm excited emission spectra a 10-variable MVLR score (using (Sigma) (lambda ) IF((lambda) ) and normalized intensities at nine wavelengths as input parameters) provided a sensitivity and specificity of 95.7% and 93.1% over the sample size investigated.

  6. Biological trait analysis and stability of lambda-cyhalothrin resistance in the house fly, Musca domestica L. (Diptera: Muscidae).

    PubMed

    Abbas, Naeem; Shah, Rizwan Mustafa; Shad, Sarfraz Ali; Iqbal, Naeem; Razaq, Muhammad

    2016-05-01

    House flies, Musca domestica L., (Diptera: Muscidae), are pests of poultry and have the ability to develop resistance to insecticides. To design a strategy for resistance management, life history traits based on laboratory observations were established for lambda-cyhalothrin-resistant, susceptible and reciprocal crosses of M. domestica strains. Bioassay results showed that the lambda-cyhalothrin-selected strain developed a resistance ratio of 98.34 compared to its susceptible strain. The lambda-cyhalothrin-selected strain had a relative fitness of 0.26 and lower fecundity, hatchability, lower number of next generation larvae, and net reproductive rate compared with its susceptible strain. Mean population growth rates, such as intrinsic rate of population increase, and biotic potential were lower for the lambda-cyhalothrin-selected strain compared to its susceptible strain. Resistance to lambda-cyhalothrin, indoxacarb, and abamectin was unstable while resistance to bifenthrin and methomyl was stable in the lambda-cyhalothrin-selected strain of M. domestica. Development of resistance can cost considerable fitness for the lambda-cyhalothrin-selected strain. The present study provided useful information for making potential management strategies to delay resistance development in M. domestica.

  7. Depolymerized products of lambda-carrageenan as a potent angiogenesis inhibitor.

    PubMed

    Chen, Haimin; Yan, Xiaojun; Lin, Jing; Wang, Feng; Xu, Weifeng

    2007-08-22

    Since angiogenesis is involved in initiating and promoting several diseases such as cancer and cardiovascular events, this study was designed to evaluate the anti-angiogenesis of low-molecular-weight (LMW), highly sulfated lambda-carrageenan oligosaccharides (lambda-CO) obtained by carrageenan depolymerization, by CAM (chick chorioallantoic membrane) model and human umbilical vein endothelial cells (HUVECs). Significant inhibition of vessel growth was observed at 200 microg/pellet. A histochemistry assay also revealed a decrease of capillary plexus and connective tissue in lambda-CO treated samples. lambda-CO inhibited the viability of cells at the high concentration of 1 mg/mL, whereas it affected the cell survival slightly (>95%) at a low concentration (<250 microg/mL), and HUVEC is the most sensitive to lambda-CO among three kinds of cells. Furthermore, the inhibitory action of lambda-CO was also observed in the endothelial cell invasion and migration at relatively low concentration (150-300 microg/mL), through down-regulation of intracellular matrix metalloproteinases (MMP-2) expression on endothelial cells. Taken together, these findings demonstrate that lambda-CO is a potential angiogenesis inhibitor with combined effects of inhibiting invasion, migration, and proliferation.

  8. Oxidative and apoptotic effects of lambda-cyhalothrin modulated by piperonyl butoxide in the liver of Oreochromis niloticus.

    PubMed

    Piner, Petek; Uner, Nevin

    2012-05-01

    The aim of this study was to investigate the toxic effects of pyrethroid pesticide lambda-cyhalothrin in the presence of piperonyl butoxide as a modulator in the liver of juvenile Oreochromis niloticus. LC(50) (96h) value of lambda-cyhalothrin was determined as 2.901μg/L for O. niloticus. The fish were exposed to 0.48μg/L (1/6 of the 96-h LC(50)) lambda-cyhalothrin and 10μg/L piperonyl butoxide for 96-h and 15-d. tGSH, GSH, GSSG, Hsp70 and TBARS contents, GPx, GR, GST and caspase-3 enzymes activities were determined. Lambda-cyhalothrin caused increases in tGSH, GSH, TBARS contents, and GST activity. Piperonyl butoxide treatment with lambda-cyhalothrin caused significant increases in tGSH GSH, Hsp70, TBARS contents, and GPx and GST activities while caspase-3 activity was decreased. The results of the present study revealed that lambda-cyhalothrin caused oxidative stress which upregulated GSH and GSH-related enzymes. Piperonyl butoxide increased the oxidative stress potential and apoptotic effects of lambda-cyhalothrin. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Determination of $${{\\rm{\\Lambda }}}_{\\overline{{\\rm{MS}}}}$$ at five loops from holographic QCD

    DOE PAGES

    Deur, Alexandre; Brodsky, Stanley J.; de Téramond, Guy F.

    2017-08-25

    Here, the recent determination of themore » $$\\beta$$--function of the QCD running coupling $$\\alpha_{\\overline{MS}}(Q^2)$$ to five-loops, provides a verification of the convergence of a novel method for determining the fundamental QCD parameter $$\\Lambda_s$$ based on the Light-Front Holographic approach to nonperturbative QCD. The new 5-loop analysis, together with improvements in determining the holographic QCD nonperturbative scale parameter $$\\kappa$$ from hadronic spectroscopy, leads to an improved precision of the value of $$\\Lambda_s$$ in the $${\\overline{MS}}$$ scheme close to a factor of two; we find $$\\Lambda^{(3)}_{\\overline{MS}}=0.339\\pm0.019$$ GeV for $$n_{f}=3$$, in excellent agreement with the world average, $$\\Lambda_{\\overline{MS}}^{(3)}=0.332\\pm0.017$$ GeV. Lastly, we also discuss the constraints imposed on the scale dependence of the strong coupling in the nonperturbative domain by superconformal quantum mechanics and its holographic embedding in anti-de Sitter space.« less

  10. IUE and Einstein observations of the LINER galaxy NGC 4579

    NASA Technical Reports Server (NTRS)

    Reichert, G. A.; Puchnarewicz, E. M.; Mason, K. O.

    1990-01-01

    Results of International Ultraviolet Explorer (IUE) and Einstein observations of the LINER galaxy NGC 4579 are reported. Spatial profiles of the long wavelength IUE emission show a two component structure, with an unresolved core superimposed on broader underlying emission. The core spectrum shows strong C II lambda 2326 and broad Mg II lambda 2800 emission, and perhaps emission due to blends of Fe II multiplets (2300 to 23600 angstrom). The short wavelength emission is spatially unresolved, and shows C II lambda 1335, C III lambda 1909 broad C IV lambda 1550 emission, and a broad feature at approximately 1360 angstrom which may be due to 0.1 lambda 1356. Contrary to previous reports no evidence for He II lambda 1640 is found in the spectrum. An unresolved x ray source is detected at the location of the nucleus; its spectrum is well fitted by a power law of energy slope alpha approximately -0.5. These results further support the idea that NGC 4579 may contain a dwarf Seyfert nucleus.

  11. Segregated tandem filter for enhanced conversion efficiency in a thermophotovoltaic energy conversion system

    DOEpatents

    Brown, Edward J.; Baldasaro, Paul F.; Dziendziel, Randolph J.

    1997-01-01

    A filter system to transmit short wavelength radiation and reflect long wavelength radiation for a thermophotovoltaic energy conversion cell comprises an optically transparent substrate segregation layer with at least one coherent wavelength in optical thickness; a dielectric interference filter deposited on one side of the substrate segregation layer, the interference filter being disposed toward the source of radiation, the interference filter including a plurality of alternating layers of high and low optical index materials adapted to change from transmitting to reflecting at a nominal wavelength .lambda..sub.IF approximately equal to the bandgap wavelength .lambda..sub.g of the thermophotovoltaic cell, the interference filter being adapted to transmit incident radiation from about 0.5.lambda..sub.IF to .lambda..sub.IF and reflect from .lambda..sub.IF to about 2.lambda..sub.IF ; and a high mobility plasma filter deposited on the opposite side of the substrate segregation layer, the plasma filter being adapted to start to become reflecting at a wavelength of about 1.5.lambda..sub.IF.

  12. [In vitro anti-angiogenic action of lambda-carrageenan oligosaccharides].

    PubMed

    Chen, Hai-Min; Yan, Xiao-Jun; Wang, Feng; Lin, Jing; Xu, Wei-Feng

    2007-06-01

    This study was designed to evaluate the inhibition effect of lambda-carrageenan oligosaccharides on neovascularization in vitro by chick chorioallantoic membrane (CAM) model and human umbilical vein endothelial cell ( HUVEC). lambda-Carrageenan oligosaccharides caused a dose-dependent decrease of the vascular density of CAM, and adversely affected capillary plexus formation. At a high concentration of 1 mg x mL(-1), this compound inhibited the endothelial cell proliferation, while low concentration of lambda-carrageenan oligosaccharides (< 250 microg x mL(-1)) affected the cell survival slightly (> 95%). Different cytotoxic sensitivity of lambda-carrageenan oligosaccharides in three kinds of cells was observed, of which HUVEC is the most sensitive to this oligosaccharides. The inhibitory action of lambda-carrageenan oligosaccharides on the endothelial cell invasion and migration was also observed at relatively low concentration (150 - 300 microg x mL(-1)) through down-regulation of intracellular matrix metalloproteinases-2 (MMP-2) expression on endothelial cells. Current observations demonstrated that lambda-carrageenan oligosaccharides are potential angiogenesis inhibitor with combined effects of inhibiting invasion, migration and proliferation.

  13. Effect of atmospheric extinction on laser rangefinder performance at 1.54 and 0.6 microns

    NASA Technical Reports Server (NTRS)

    Hutt, D. L.; Theriault, J.-M.; Larochelle, V.; Bonnier, D.

    1992-01-01

    Extinction of laser rangefinder (LRF) pulses by the atmosphere depends on the wavelength, weather conditions, and aerosol concentration along the optical path. In the IR, extinction is due to absorption by molecular constituents and scattering and absorption by aerosols. The total atmospheric extinction alpha(lambda) is the sum of the molecular and aerosol contributions, alpha(sub m)(lambda)and Alpha(sub a)(lambda). We present simple expressions for alpha(sub m)(lambda) and alpha(sub a)(lambda) for two LRF sources: Er:glass and CO2 which operate at 1.54 and 10.6 microns, respectively. The expressions are based on accepted models of atmospheric aerosols and molecular extinction and give an estimate of alpha(lambda) as a function of standard meteorological parameters, assuming horizontal beam propagation. Signal-to-noise ratios of LRF returns, measured from a reference target under different weather conditions are compared to predictions based on the estimate of alpha(lambda).

  14. On Spectral Invariance of Single Scattering Albedo for Water Droplets and Ice Crystals at Weakly Absorbing Wavelengths

    NASA Technical Reports Server (NTRS)

    Marshak, Alexander; Knyazikhin, Yuri; Chiu, J. Christine; Wiscombe, Warren J.

    2012-01-01

    The single scattering albedo omega(sub O lambda) in atmospheric radiative transfer is the ratio of the scattering coefficient to the extinction coefficient. For cloud water droplets both the scattering and absorption coefficients, thus the single scattering albedo, are functions of wavelength lambda and droplet size r. This note shows that for water droplets at weakly absorbing wavelengths, the ratio omega(sub O lambda)(r)/omega(sub O lambda)(r (sub O)) of two single scattering albedo spectra is a linear function of omega(sub O lambda)(r). The slope and intercept of the linear function are wavelength independent and sum to unity. This relationship allows for a representation of any single scattering albedo spectrum omega(sub O lambda)(r) via one known spectrum omega(sub O lambda)(r (sub O)). We provide a simple physical explanation of the discovered relationship. Similar linear relationships were found for the single scattering albedo spectra of non-spherical ice crystals.

  15. Duality symmetry and power-law fading of frustration in a quantum multiconnected superconductor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, S.N.; Ralston, J.P.

    1991-03-01

    We generalize the Alexander--de Gennes equations to a new system of superconducting-wire networks, allowing for variation of the cross-sectional area of wires. The generalized equations are solved for a square lattice of different cross-sectional-area ratios {lambda} in the {ital x} and {ital y} directions. A symmetry of {lambda}{r arrow}1/{lambda} is related to the Aubry-Andre duality and an obvious geometric property. We find that even a slight geometric asymmetry can soften the fine structure of the magnetic phase boundary considerably. We obtain a power-law dependence on the parameter {lambda} as {lambda}{r arrow}{infinity} and {lambda}{r arrow}0. For a finite-area ratio {lambda}, wemore » speculate that a simple analytic fit incorporating the dual symmetry is close to the exact nonperturbative behavior. The system is also related analytically to a recent study of Hu and Chen, which revealed a power-law behavior for a rectangular lattice.« less

  16. Evaluation of the RT-LAMP and LAMP methods for detection of Mycobacterium tuberculosis.

    PubMed

    Wu, Dandan; Kang, Jiwen; Li, Baosheng; Sun, Dianxing

    2018-05-01

    The current methods for detecting Mycobacterium tuberculosis (Mtb) are not clinically optimal. Standard culture methods (SCMs) are slow, costly, or unreliable, and loop-mediated isothermal amplification (LAMP) cannot differentiate live Mtb. This study compared reverse transcription (RT)-LAMP, LAMP, and an SCM for detecting Mtb. A first experiment tested the sensitivity and specificity of primers for 9 species of Mycobacterium (H37Rv, M. intracellulare, M. marinum, M. kansasii, M. avium, M. flavescens, M. smegmatis, M. fortuitum, and M. chelonae); and 3 non-Mycobacterium species (Staphylococcus aureus, Pseudomonas aeruginosa, and Klebsiella pneumoniae). A second experiment tested sputum specimens for the presence of Mtb, from 100 patients with tuberculosis (clinical) and 22 from patients without tuberculosis (control), using Roche solid culture (SCM), LAMP, and RT-LAMP. In the clinical samples. The rates of positivity for Mtb of the SCM, LAMP, and RT-LAMP methods were 88%, 92%, and 100%, respectively. The difference in detection rate was significant between RT-LAMP and SCM, but RT-LAMP and LAMP were comparable. In the control group, the detection rates were nil for all three methods. The specificities of the methods were similar. The sensitivity of RT-LAMP was ~10-fold higher than that of LAMP for detecting Mtb. Unlike LAMP, RT-LAMP could identify viable bacteria, and was able to detect a single copy of Mtb. Among SCM, LAMP, and RT-LAMP, the latter is the most suitable for wide use in the lower-level hospitals and clinics of China for detecting Mtb in sputum samples. © 2017 Wiley Periodicals, Inc.

  17. Further improvements of a new model for turbulent convection in stars

    NASA Technical Reports Server (NTRS)

    Canuto, V. M.; Mazzitelli, I.

    1992-01-01

    The effects of including a variable molecular weight and of using the newest opacities of Rogers and Iglesias (1991) as inputs to a recent model by Canuto and Mazzitelli (1991) for stellar turbulent convection are studied. Solar evolutionary tracks are used to conclude that the the original model for turbulence with mixing length Lambda = z, Giuli's variable Q unequal to 1 and the new opacities yields a fit to solar T(eff) within 0.5 percent. A formulation of Lambda is proposed that extends the purely nonlocal Lambda = z expression to include local effects. A new expression for Lambda is obtained which generalizes both the mixing length theory (MLT) phenomenological expression for Lambda as well as the model Lambda = z. It is argued that the MLT should now be abandoned.

  18. Rayleigh, the unit for light radiance.

    PubMed

    Baker, D J

    1974-09-01

    A 0.7% accurate formula is derived for the easy conversion of power spectral radiance L(lambda) in W cm(-2) sr(-1) microm(-1)to rayleigh spectral radiance R(lambda) in rayleigh/microm, R(lambda) = 2pilambdaL(lambda) x 10(13), where the wavelength lambda is in microm. The rationale for the rayleigh unit is discussed in terms of a photon rate factor and a solid angle factor. The latter is developed in terms of an equivalence theorem about optical receivers and extended sources, and the concept is extended to the computation of photon volume emission rates from altitude profiles of zenith radiance.

  19. Comparison of direct and alternating current vacuum ultraviolet lamps in atmospheric pressure photoionization.

    PubMed

    Vaikkinen, Anu; Haapala, Markus; Kersten, Hendrik; Benter, Thorsten; Kostiainen, Risto; Kauppila, Tiina J

    2012-02-07

    A direct current induced vacuum ultraviolet (dc-VUV) krypton discharge lamp and an alternating current, radio frequency (rf) induced VUV lamp that are essentially similar to lamps in commercial atmospheric pressure photoionization (APPI) ion sources were compared. The emission distributions along the diameter of the lamp exit window were measured, and they showed that the beam of the rf lamp is much wider than that of the dc lamp. Thus, the rf lamp has larger efficient ionization area, and it also emits more photons than the dc lamp. The ionization efficiencies of the lamps were compared using identical spray geometries with both lamps in microchip APPI mass spectrometry (μAPPI-MS) and desorption atmospheric pressure photoionization-mass spectrometry (DAPPI-MS). A comprehensive view on the ionization was gained by studying six different μAPPI solvent compositions, five DAPPI spray solvents, and completely solvent-free DAPPI. The observed reactant ions for each solvent composition were very similar with both lamps except for toluene, which showed a higher amount of solvent originating oxidation products with the rf lamp than with the dc lamp in μAPPI. Moreover, the same analyte ions were detected with both lamps, and thus, the ionization mechanisms with both lamps are similar. The rf lamp showed a higher ionization efficiency than the dc lamp in all experiments. The difference between the lamp ionization efficiencies was greatest when high ionization energy (IE) solvent compositions (IEs above 10 eV), i.e., hexane, methanol, and methanol/water, (1:1 v:v) were used. The higher ionization efficiency of the rf lamp is likely due to the larger area of high intensity light emission, and the resulting larger efficient ionization area and higher amount of photons emitted. These result in higher solvent reactant ion production, which in turn enables more efficient analyte ion production. © 2012 American Chemical Society

  20. Development of loop-mediated isothermal amplification methods for detecting Taylorella equigenitalis and Taylorella asinigenitalis

    PubMed Central

    KINOSHITA, Yuta; NIWA, Hidekazu; KATAYAMA, Yoshinari; HARIU, Kazuhisa

    2015-01-01

    ABSTRACT Taylorella equigenitalis is a causative bacterium of contagious equine metritis (CEM), and Taylorella asinigenitalis is species belonging to genus Taylorella. The authors developed two loop-mediated isothermal amplification (LAMP) methods, Te-LAMP and Ta-LAMP, for detecting T. equigenitalis and T. asinigenitalis, respectively. Using experimentally spiked samples, Te-LAMP was as sensitive as a published semi-nested PCR method, and Ta-LAMP was more sensitive than conventional PCR. Multiplex LAMP worked well without nonspecific reactions, and the analytical sensitivities of multiplex LAMP in the spiked samples were almost equivalent to those of Te-LAMP and Ta-LAMP. Therefore, the LAMP methods are considered useful tools to detect T. equigenitalis and/or T. asinigenitalis, and preventive measures will be rapidly implemented if the occurrence of CEM is confirmed by the LAMP methods. PMID:25829868

  1. Total enantioselectivity in the DNA binding of the dinuclear ruthenium(II) complex [[Ru(Me2bpy)2]2(mu-bpm)]4+ [bpm = 2,2'-bipyrimidine; Me2bpy = 4,4'-dimethyl-2,2'-bipyridine].

    PubMed

    Smith, Jayden A; Collins, J Grant; Patterson, Bradley T; Keene, F Richard

    2004-05-07

    The binding of the three stereoisomers (DeltaDelta-, LambdaLambda- and DeltaLambda-) of the dinuclear ruthenium(II) complex [[Ru(Me2bpy)2]2(mu-bpm)]4+ [Me2bpy = 4,4'-dimethyl-2,2'-bipyridine; bpm = 2,2'-bipyrimidine] to a tridecanucleotide containing a single adenine bulge has been studied by 1H NMR spectroscopy. The addition of the DeltaDelta-isomer to d(CCGAGAATTCCGG)2 induced significant chemical shift changes for the base and sugar resonances of the residues at the bulge site (G3A4G5/C11C10), whereas small shifts were observed upon addition of the enantiomeric LambdaLambda-form. NOESY spectra of the tridecanucleotide bound with the DeltaDelta-isomer revealed intermolecular NOE's between the metal complex and the nucleotide residues at the bulge site, while only weak NOE's were observed to terminal residues to the LambdaLambda-form. Competitive binding studies were performed where both enantiomers were simultaneously added to the tridecanucleotide, and for all ratios of the two stereoisomers the DeltaDelta-isomer remained selectively bound at the bulge site with the LambdaLambda-enantiomer localised at the terminal regions of the tridecanucleotide. The meso-diastereoisomer (DeltaLambda) was found to bind to the tridecanucleotide with characteristics intermediate between the DeltaDelta- and LambdaLambda-enantiomers of the rac form. Two distinct sets of metal complex resonances were observed, with one set having essentially the same shift as the free metal complex, whilst the other set of resonances exhibited significant shifts. The NOE data indicated that the meso-diastereoisomer does not bind as selectively as the DeltaDelta-isomer, with NOE's observed to a greater number of nucleotide residues compared to the DeltaDelta-form. This study provides a rare example of total enantioselectivity in the binding of an inert transition metal complex to DNA, produced by the shape recognition of both ruthenium(II) centres.

  2. Somatic diversification of chicken immunoglobulin light chains by point mutations.

    PubMed

    Parvari, R; Ziv, E; Lantner, F; Heller, D; Schechter, I

    1990-04-01

    The light-chain locus of chicken has 1 functional V lambda 1 gene, 1 J gene, and 25 pseudo-V lambda-genes (where V = variable and J = joining). A major problem is which somatic mechanisms expand this extremely limited germ-line information to generate many different antibodies. Weill's group [Reynaud, C. A., Anquez, V., Grimal, H. & Weill, J. C. (1987) Cell 48, 379-388] has shown that the pseudo-V lambda-genes diversify the rearranged V lambda 1 by gene conversion. Here we demonstrate that chicken light chains are further diversified by somatic point mutations and by V lambda 1-J flexible joining. Somatic point mutations were identified in the J and 3' noncoding DNA of rearranged light-chain genes of chicken. These regions were analyzed because point mutations in V lambda 1 are obscured by gene conversion; the J and 3' noncoding DNA are presented in one copy per haploid genome and are not subject to gene conversion. In rodents point mutations occur as frequently in the V-J coding regions as in the adjacent flanking DNA. Therefore, we conclude that somatic point mutations diversify the V lambda 1 of chicken. The frequency (0-1%) and distribution of the mutations (decreasing in number with increased distance from the V lambda 1 segment) in chicken were as observed in rodents. Sequence variability at the V lambda 1-J junctions could be attributed to imprecise joining of the V lambda 1 and J genes. The modification by gene conversion of rearranged V lambda 1 genes in the bursa was similar in chicken aged 3 months (9.5%) or 3 weeks (9.1%)--i.e., gene conversion that generates the preimmune repertoire in the bursa seems to level off around 3 weeks of age. This preimmune repertoire can be further diversified by somatic point mutations that presumably lead to the formation of antibodies with increased affinity. A segment with structural features of a matrix association region [(A + T)-rich and four topoisomerase II binding sites] was identified in the middle of the J-C lambda intron (where C = constant).

  3. Pathophysiology of Corneal Scarring in Persistent Epithelial Defects After PRK and Other Corneal Injuries.

    PubMed

    Wilson, Steven E; Medeiros, Carla S; Santhiago, Marcony R

    2018-01-01

    To analyze corneal persistent epithelial defects that occurred at 3 to 4 weeks after -4.50 diopter (D) photorefractive keratectomy (PRK) in rabbits and apply this pathophysiology to the treatment of persistent epithelial defects that occur after any corneal manipulations or diseases. Two of 168 corneas that had -4.50 D PRK to study epithelial basement membrane regeneration developed spontaneous persistent epithelial defects that did not heal at 3 weeks after PRK. These were studied with slit-lamp photographs, immunohistochemistry for the myofibroblast marker alpha-smooth muscle actin (α-SMA), and transmission electron microscopy. Myofibroblasts developed at the stromal surface within the persistent epithelial defect and for a short distance peripheral to the leading edge of the epithelium. No normal epithelial basement membrane was detectable within the persistent epithelial defect or for up to 0.3 mm behind the leading edge of the epithelium, although epithelial basement membrane had normally regenerated in other areas of the zone ablated by an excimer laser where the epithelium healed promptly. A persistent epithelial defect in the cornea results in the development of myofibroblasts and disordered extracellular matrix produced by these cells that together cause opacity within, and a short distance beyond, the persistent epithelial defect. Clinicians should treat persistent epithelial defects within 10 days of non-closure of the epithelium to facilitate epithelial healing to prevent long-term stromal scarring (fibrosis). [J Refract Surg. 2018;34(1):59-64.]. Copyright 2018, SLACK Incorporated.

  4. Tertiary structure of human {Lambda}6 light chains.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pokkuluri, P. R.; Solomon, A.; Weiss, D. T.

    1999-01-01

    AL amyloidosis is a disease process characterized by the pathologic deposition of monoclonal light chains in tissue. To date, only limited information has been obtained on the molecular features that render such light chains amyloidogenic. Although protein products of the major human V kappa and V lambda gene families have been identified in AL deposits, one particular subgroup--lambda 6--has been found to be preferentially associated with this disease. Notably, the variable region of lambda 6 proteins (V lambda 6) has distinctive primary structural features including the presence in the third framework region (FR3) of two additional amino acid residues thatmore » distinguish members of this subgroup from other types of light chains. However, the structural consequences of these alterations have not been elucidated. To determine if lambda 6 proteins possess unique tertiary structural features, as compared to light chains of other V lambda subgroups, we have obtained x-ray diffraction data on crystals prepared from two recombinant V lambda 6 molecules. These components, isolated from a bacterial expression system, were generated from lambda 6-related cDNAs cloned from bone marrow-derived plasma cells from a patient (Wil) who had documented AL amyloidosis and another (Jto) with multiple myeloma and tubular cast nephropathy, but no evident fibrillar deposits. The x-ray crystallographic analyses revealed that the two-residue insertion located between positions 68 and 69 (not between 66 and 67 as previously surmised) extended an existing loop region that effectively increased the surface area adjacent to the first complementarity determining region (CDR1). Further, an unusual interaction between the Arg 25 and Phe 2 residues commonly found in lambda 6 molecules was noted. However, the structures of V lambda 6 Wil and Jto also differed from each other, as evidenced by the presence in the latter of certain ionic and hydrophobic interactions that we posit increased protein stability and thus prevented amyloid formation.« less

  5. FAR-ULTRAVIOLET SPECTRAL IMAGES OF THE VELA SUPERNOVA REMNANT: SUPPLEMENTS AND COMPARISONS WITH OTHER WAVELENGTH IMAGES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Il-Joong; Seon, Kwang-Il; Han, Wonyong

    We present the improved far-ultraviolet (FUV) emission-line images of the entire Vela supernova remnant (SNR) using newly processed Spectroscopy of Plasma Evolution from Astrophysical Radiation/Far-Ultraviolet Imaging Spectrograph (SPEAR/FIMS) data. The incomplete C III {lambda}977 and O VI {lambda}{lambda}1032, 1038 images presented in the previous study are updated to cover the whole region. The C IV {lambda}{lambda}1548, 1551 image with a higher resolution and new images at Si IV {lambda}{lambda}1394, 1403, O IV] {lambda}1404, He II {lambda}1640.5, and O III] {lambda}{lambda}1661, 1666 are also shown. Comparison of emission-line ratios for two enhanced FUV regions reveals that the FUV emissions of themore » east-enhanced FUV region may be affected by nonradiative shocks of another very young SNR, the Vela Jr. SNR (RX J0852.0-4622, G266.6-1.2). This result is the first FUV detection that is likely associated with the Vela Jr. SNR, supporting previous arguments that the Vela Jr. SNR is close to us. The comparison of the improved FUV images with soft X-ray images shows that an FUV filamentary feature forms the boundary of the northeast-southwest asymmetrical sections of the X-ray shell. The southwest FUV features are characterized as the region where the Vela SNR is interacting with slightly denser ambient medium within the dim X-ray southwest section. From a comparison with the H{alpha} image, we identify a ring-like H{alpha} feature overlapped with an extended hot X-ray feature of similar size and two local peaks of C IV emission. Their morphologies are expected when the H{alpha} ring is in direct contact with the near or far side of the Vela SNR.« less

  6. Preliminary results of VISX excimer laser myopic photorefractive keratectomy at Cedars-Sinai Medical Center

    NASA Astrophysics Data System (ADS)

    Maguen, Ezra I.; Berlin, Michael S.; Hofbauer, John; Macy, Jonathan I.; Nesburn, Anthony B.; Papaioannou, Thanassis; Salz, James J.

    1992-08-01

    Sixty-two eyes underwent excimer laser photorefractive keratectomy (PRK) for the correction of myopia at Cedars-Sinai-Medical-Center. The first group of 12 patients are presented with follow up data of ten months postoperatively. The second group of 50 patients are presented with follow up data of three months postoperatively. An in-depth comparison of pre and postoperative refractive data is presented. Comparisons between pre and postoperative corrected and uncorrected Snellen visual acuities are provided in order to asses the functional visual result of the procedure.

  7. Electronic-beam analysis of excimer lasers used for photorefractive keratotomy

    NASA Astrophysics Data System (ADS)

    Roundy, Carlos B.

    1998-07-01

    Excimer lasers are an excellent instrument for performing photorefractive keratotomy, PRK. The UV light from the laser causes an ablation of the cornea in proportion to the intensity of the light. The primary characteristic essential to successful PRK is the uniformity of the Top Hat, or working portion of the laser beam. In order for this intensity profile to be sufficiently uniform for PRK, it is essential to periodically measure the equality of the laser beam profile. This ensures that the laser continues to operate properly and provide the expected performance.

  8. Fabrication of self-organized conical microstructures by excimer laser irradiation of cyanoacrylate-carbon nanotube composites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu Yuming; Liu Liang; Fan Shoushan

    2005-02-07

    Self-organized conical microstructures are fabricated by 308 nm XeCl excimer laser irradiation of cyanoacrylate-carbon nanotube composites in air. The morphology of the surface on the composite films is studied, varying the total number and fluence of the applied laser pulses. A simple mechanism of the fabrication based on the evaporation of cyanoacrylate and the burning of carbon nanotubes is proposed. The conical peak structures of cyanoacrylate-carbon nanotube composite films show good field-emission properties. Similar structures are also observed on carbon nanotube arrays.

  9. Hydroxyl Tagging Velocimetry in a Mach 2 Flow With a Wall Cavity (Postprint)

    DTIC Science & Technology

    2005-01-01

    tagging velocimetry (HTV) measurements of velocity were made in a Mach 2 flow with a wall cavity. In the HTV method, ArF excimer laser (193 nm) beams...is tracked by planar laser -induced fluorescence. The grid motion over a fixed time delay yields about 50 velocity vectors of the two-dimensional flow...Mach 2 flow with a wall cavity. In the HTV method, ArF excimer laser (193 nm) beams pass through a humid gas and dissociate H2O into H + OH to form

  10. Hydroxyl Tagging Velocimetry in Cavity-Piloted Mach 2 Combustor (Postprint)

    DTIC Science & Technology

    2006-01-01

    combustor with a wall cavity flameholder. In the HTV method, ArF excimer laser (193 nm) beams pass through a humid gas flow and dissociate H2O into H...grid of OH tracked by planar laser -induced fluorescence to yield about 120 velocity vectors of the two-dimensional flow over a fixed time delay...with a wall cavity flameholder. In the HTV method, ArF excimer laser (193 nm) beams pass through a humid gas flow and dissociate H2O into H + OH to

  11. Limits on the Decay-Rate Difference of Neutral-B Mesons and on CP, T, and CPT Violation in B0-antiB0 Oscillations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aubert, B

    2004-02-29

    Using events in which one of two neutral-B mesons from the decay of an {Upsilon}(4S) resonance is fully reconstructed, we set limits on the difference between the decay rates of the two neutral-B mass eigenstates and on CP, T, and CPT violation in B{sup 0}{bar B}{sup 0} mixing. The reconstructed decays, comprising both CP and flavor eigenstates, are obtained from 88 million {Upsilon}(4S) {yields} B{bar B} decays collected with the BABAR detector at the PEP-II asymmetric-energy B Factory at SLAC. We determine six independent parameters governing oscillations ({Delta}m, {Delta}{Lambda}/{Lambda}), CPT and CP violation (Re z, Im z), and CP andmore » T violation (Im {lambda}{sub CP}, |q/p|), where {lambda}{sub cp} characterizes B{sup 0} and {bar B}{sup 0} decays to states of charmonium plus K{sub S}{sup 0} or K{sub L}{sup 0}. The results are sgn(Re {lambda}{sub CP}){Delta}{Lambda}/{Lambda} = .0.008 {+-} 0.037(stat.) {+-} 0.018(syst.) [-0.084, 0.068], |q/p| = 1.029 {+-} 0.013(stat.) {+-} 0.011(syst.) [1.001, 1.057], (Re {lambda}{sub CP}/|{lambda}{sub CP}|)Re z = 0.014 {+-} 0.035(stat.) {+-} 0.034(syst.) [-0.072, 0.101], Imz = 0.038 {+-} 0.029(stat.) {+-} 0.025(syst.) [-0.028, 0.104]. The values inside square brackets indicate the 90% confidence-level intervals. The values of Im {lambda}{sub CP} and {Delta}m are consistent with previous analyses and are used as cross-checks. These measurements are in agreement with Standard Model expectations.« less

  12. Lysosome associated membrane proteins maintain pancreatic acinar cell homeostasis: LAMP-2 deficient mice develop pancreatitis.

    PubMed

    Mareninova, Olga A; Sendler, Matthias; Malla, Sudarshan Ravi; Yakubov, Iskandar; French, Samuel W; Tokhtaeva, Elmira; Vagin, Olga; Oorschot, Viola; Lüllmann-Rauch, Renate; Blanz, Judith; Dawson, David; Klumperman, Judith; Lerch, Markus M; Mayerle, Julia; Gukovsky, Ilya; Gukovskaya, Anna S

    2015-11-01

    The pathogenic mechanism of pancreatitis is poorly understood. Recent evidence implicates defective autophagy in pancreatitis responses; however, the pathways mediating impaired autophagy in pancreas remain largely unknown. Here, we investigate the role of lysosome associated membrane proteins (LAMPs) in pancreatitis. We analyzed changes in LAMPs in experimental models and human pancreatitis, and the underlying mechanisms: LAMP de-glycosylation and degradation. LAMP cleavage by cathepsin B (CatB) was analyzed by mass spectrometry. We used mice deficient in LAMP-2 to assess its role in pancreatitis. Pancreatic levels of LAMP-1 and LAMP-2 greatly decrease across various pancreatitis models and in human disease. Pancreatitis does not trigger LAMPs' bulk de-glycosylation, but induces their degradation via CatB-mediated cleavage of LAMP molecule close to the boundary between luminal and transmembrane domains. LAMP-2 null mice spontaneously develop pancreatitis that begins with acinar cell vacuolization due to impaired autophagic flux, and progresses to severe pancreas damage characterized by trypsinogen activation, macrophage-driven inflammation, and acinar cell death. LAMP-2 deficiency causes a decrease in pancreatic digestive enzymes content, stimulates the basal and inhibits CCK-induced amylase secretion by acinar cells. The effects of LAMP-2 knockout and acute cerulein pancreatitis overlap, which corroborates the pathogenic role of LAMP decrease in experimental pancreatitis models. The results indicate a critical role for LAMPs, particularly LAMP-2, in maintaining pancreatic acinar cell homeostasis, and provide evidence that defective lysosomal function, resulting in impaired autophagy, leads to pancreatitis. Mice with LAMP-2 deficiency present a novel genetic model of human pancreatitis caused by lysosomal/autophagic dysfunction.

  13. Excimer laser produced plasmas in copper wire targets and water droplets

    NASA Technical Reports Server (NTRS)

    Song, Kyo-Dong; Alexander, D. R.

    1994-01-01

    Elastically scattered incident radiation (ESIR) from a copper wire target illuminated by a KrF laser pulse at lambda = 248 nm shows a dinstinct two-peak structure which is dependent on the incident energy. The time required to reach the critical electron density (n(sub c) approximately = 1.8 x 10(exp 22) electrons/cu cm) is estimated at 11 ns based on experimental results. Detailed ESIR characteristics for water have been reported previously by the authors. Initiation of the broadband emission for copper plasma begins at 6.5 +/- 1.45 ns after the arrival of the laser pulse. However, the broadband emission occurs at 11 +/- 0.36 ns for water. For a diatomic substance such as water, the electron energy rapidly dissipates due to dissociation of water molecules, which is absent in a monatomic species such as copper. When the energy falls below the excitation energy of the lowest electron state for water, it becomes a subexcitation electron. Lifetimes of the subexcited electrons to the vibrational states are estimated to be of the order of 10(exp -9) s. In addition, the ionization potential of copper (440-530 nm) is approximately 6 eV, which is about two times smaller than the 13 eV ionization potential reported for water. The higher ionization potential contributes to the longer observed delay time for plasma formation in water. After initiation, a longer time is required for copper plasma to reach its peak value. This time delay in reaching the maximum intensity is attributed to the energy loss during the interband transition in copper.

  14. Simple model for lambda-doublet propensities in bimolecular reactions

    NASA Technical Reports Server (NTRS)

    Bronikowski, Michael J.; Zare, Richard N.

    1990-01-01

    A simple geometric model is presented to account for lambda-doublet propensities in bimolecular reactions A + BC - AB + C. It applies to reactions in which AB is formed in a pi state, and in which the unpaired molecular orbital responsible for lambda-doubling arises from breaking the B-C bond. The lambda-doublet population ratio is predicted to be 2:1 provided that: (1) the motion of A in the transition state determines the plane of rotation of AB; (2) the unpaired pi orbital lying initially along the B-C bond may be resolved into a projection onto the AB plane of rotation and a projection perpendicular to this plane; (3) there is no preferred geometry for dissociation of ABC. The 2:1 lambda-doublet ratio is the 'unconstrained dynamics prior' lambda-doublet distribution for such reactions.

  15. Effective screening length of isotropic liquid samples submitted to an applied voltage.

    PubMed

    Zola, R S; Evangelista, L R; Barbero, G

    2006-05-25

    A cell of isotropic liquid in the shape of a slab of thickness d and containing ionic impurities is considered. It is shown that the screening effect produced by the ionic charges on the external field is characterized by an effective surface length, lambda(S)(U), depending on the applied voltage U. The analysis indicates that lambda(S)(U)) < lambda(D) when the applied voltage is very large, and lambda(S)(U) --> lambda(D) for very small values of the applied voltage, where lambda(D) is the Debye screening length. The presence of the ions is responsible also for a counterpotential, v, that for small U is such to cancel the effective electric field in the sample, whereas in the opposite limit it is inversely proportional to the applied difference of potential.

  16. The Legacy Archive for Microwave Background Data Analysis (LAMBDA)

    NASA Astrophysics Data System (ADS)

    Miller, Nathan; LAMBDA

    2018-01-01

    The Legacy Archive for Microwave Background Data Analysis (LAMBDA) provides CMB researchers with archival data for cosmology missions, software tools, and links to other sites of interest. LAMBDA is one-stop shopping for CMB researchers. It hosts data from WMAP along with many suborbital experiments. Over the past year, LAMBDA has acquired new data from SPTpol, SPIDER and ACTPol. In addition to the primary CMB, LAMBDA also provides foreground data.LAMBDA has several ongoing efforts to provide tools for CMB researchers. These tools include a web interface for CAMB and a web interface for a CMB survey footprint database and plotting tool. Additionally, we have recently developed a Docker container with standard CMB analysis tools and demonstrations in the form of Jupyter notebooks. These containers will be publically available through Docker's container repository and the source will be available on github.

  17. Interferon lambda 1-3 expression in infants hospitalized for RSV or HRV associated bronchiolitis.

    PubMed

    Selvaggi, Carla; Pierangeli, Alessandra; Fabiani, Marco; Spano, Lucia; Nicolai, Ambra; Papoff, Paola; Moretti, Corrado; Midulla, Fabio; Antonelli, Guido; Scagnolari, Carolina

    2014-05-01

    The airway expression of type III interferons (IFNs) was evaluated in infants hospitalized for respiratory syncytial virus (RSV) or rhinovirus (HRV) bronchiolitis. As an additional objective we sought to determine whether a different expression of IFN lambda 1-3 was associated with different harboring viruses, the clinical course of bronchiolitis or with the levels of well established IFN stimulated genes (ISGs), such as mixovirus resistance A (MxA) and ISG56. The analysis was undertaken in 118 infants with RSV or HRV bronchiolitis. Nasopharyngeal washes were collected for virological studies and molecular analysis of type III IFN responses. RSV elicited higher levels of IFN lambda subtypes when compared with HRV. A similar expression of type III IFN was found in RSVA or RSVB infected infants and in those infected with HRVA or HRVC viruses. Results also indicate that IFN lambda 1 and IFN lambda 2-3 levels were correlated with each other and with MxA and ISG56-mRNAs. In addition, a positive correlation exists between the IFN lambda1 levels and the clinical score index during RSV infection. In particular, higher IFN lambda 1 levels are associated to an increase of respiratory rate. These findings show that differences in the IFN lambda 1-3 levels in infants with RSV or HRV infections are present and that the expression of IFN lambda 1 correlates with the severity of RSV bronchiolitis. Copyright © 2014 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  18. The protein interaction map of bacteriophage lambda

    PubMed Central

    2011-01-01

    Background Bacteriophage lambda is a model phage for most other dsDNA phages and has been studied for over 60 years. Although it is probably the best-characterized phage there are still about 20 poorly understood open reading frames in its 48-kb genome. For a complete understanding we need to know all interactions among its proteins. We have manually curated the lambda literature and compiled a total of 33 interactions that have been found among lambda proteins. We set out to find out how many protein-protein interactions remain to be found in this phage. Results In order to map lambda's interactions, we have cloned 68 out of 73 lambda open reading frames (the "ORFeome") into Gateway vectors and systematically tested all proteins for interactions using exhaustive array-based yeast two-hybrid screens. These screens identified 97 interactions. We found 16 out of 30 previously published interactions (53%). We have also found at least 18 new plausible interactions among functionally related proteins. All previously found and new interactions are combined into structural and network models of phage lambda. Conclusions Phage lambda serves as a benchmark for future studies of protein interactions among phage, viruses in general, or large protein assemblies. We conclude that we could not find all the known interactions because they require chaperones, post-translational modifications, or multiple proteins for their interactions. The lambda protein network connects 12 proteins of unknown function with well characterized proteins, which should shed light on the functional associations of these uncharacterized proteins. PMID:21943085

  19. Dispenser printed electroluminescent lamps on textiles for smart fabric applications

    NASA Astrophysics Data System (ADS)

    de Vos, Marc; Torah, Russel; Tudor, John

    2016-04-01

    Flexible electroluminescent (EL) lamps are fabricated onto woven textiles using a novel dispenser printing process. Dispenser printing utilizes pressurized air to deposit ink onto a substrate through a syringe and nozzle. This work demonstrates the first use of this technology to fabricate EL lamps. The luminance of the dispenser printed EL lamps is compared to screen-printed EL lamps, both printed on textile, and also commercial EL lamps on polyurethane film. The dispenser printed lamps are shown to have a 1.5 times higher luminance than the best performing commercially available lamp, and have a comparable performance to the screen-printed lamps.

  20. 49 CFR 393.24 - Requirements for head lamps, auxiliary driving lamps and front fog lamps.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... this paragraph. (b) Auxiliary driving lamps and front fog lamps. Commercial motor vehicles may be... Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective...

  1. Risk assessment of lambda-cyhalothrin on aquatic organisms in paddy field in China.

    PubMed

    Gu, Bao G; Wang, Hui M; Chen, William L; Cai, Dao J; Shan, Zheng J

    2007-06-01

    This study was carried out to assess the risk of lambda-cyhalothrin to aquatic organisms used in paddy field, and to provide assistance in the ecological risk management of lambda-cyhalothrin. The acute toxicities of five individual formulations of lambda-cyhalothrin to four aquatic species were investigated in the laboratory, as well as in a simulated paddy field-pond ecosystem, and the results implicated that lambda-cyhalothrin is highly toxic to fish, and to a greater extent to shrimp. There were differences in the toxicities to each aquatic organisms among different formulations. lambda-Cyhalothrin degraded rapidly in the environment, with half-lives of different formulations in paddy field water (0.23-0.53 days), pond water (0.38-0.63 days), and paddy field soil (0.96-7.35 days), respectively. The water overflow from the paddy field following a simulated rainstorm 12h after application of lambda-cyhalothrin did not cause injury to fish, clam or crab, but was severely hazardous to shrimp. Additionally, no injury to shrimp was found when simulated overflow occurred 4 days after application. These results suggest that the environmental risk of lambda-cyhalothrin to aquatic organisms can be reduced by (1) developing a relatively safe formulation such as a suspension concentrate, and/or (2) controlling the drainage time of the paddy field.

  2. 10 CFR 431.282 - Test Procedures [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... EQUIPMENT Mercury Vapor Lamp Ballasts § 431.282 Definitions concerning mercury vapor lamp ballasts. Ballast...) The arc tube wall loading is in excess of 3 Watts/cm2, including such lamps that are mercury vapor, metal halide, and high-pressure sodium lamps. Mercury vapor lamp means a high intensity discharge lamp...

  3. 10 CFR 431.282 - Test Procedures [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... EQUIPMENT Mercury Vapor Lamp Ballasts § 431.282 Definitions concerning mercury vapor lamp ballasts. Ballast...) The arc tube wall loading is in excess of 3 Watts/cm2, including such lamps that are mercury vapor, metal halide, and high-pressure sodium lamps. Mercury vapor lamp means a high intensity discharge lamp...

  4. 10 CFR 431.282 - Test Procedures [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... EQUIPMENT Mercury Vapor Lamp Ballasts § 431.282 Definitions concerning mercury vapor lamp ballasts. Ballast...) The arc tube wall loading is in excess of 3 Watts/cm2, including such lamps that are mercury vapor, metal halide, and high-pressure sodium lamps. Mercury vapor lamp means a high intensity discharge lamp...

  5. 10 CFR 431.282 - Test Procedures [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... EQUIPMENT Mercury Vapor Lamp Ballasts § 431.282 Definitions concerning mercury vapor lamp ballasts. Ballast...) The arc tube wall loading is in excess of 3 Watts/cm2, including such lamps that are mercury vapor, metal halide, and high-pressure sodium lamps. Mercury vapor lamp means a high intensity discharge lamp...

  6. 49 CFR 393.11 - Lamps and reflective devices.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 5 2012-10-01 2012-10-01 false Lamps and reflective devices. 393.11 Section 393... ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.11 Lamps and reflective devices. (a)(1) Lamps and reflex reflectors. Table 1 specifies the requirements for lamps...

  7. 10 CFR 429.40 - Candelabra base incandescent lamps and intermediate base incandescent lamps.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Candelabra base incandescent lamps and intermediate base incandescent lamps. 429.40 Section 429.40 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION CERTIFICATION....40 Candelabra base incandescent lamps and intermediate base incandescent lamps. (a) Sampling plan for...

  8. 49 CFR 393.11 - Lamps and reflective devices.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 5 2014-10-01 2014-10-01 false Lamps and reflective devices. 393.11 Section 393... ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.11 Lamps and reflective devices. (a)(1) Lamps and reflex reflectors. Table 1 specifies the requirements for lamps...

  9. LAMP-3 (Lysosome-Associated Membrane Protein 3) Promotes the Intracellular Proliferation of Salmonella typhimurium.

    PubMed

    Lee, Eun-Ju; Park, Kwan-Sik; Jeon, In-Sook; Choi, Jae-Woon; Lee, Sang-Jeon; Choy, Hyun E; Song, Ki-Duk; Lee, Hak-Kyo; Choi, Joong-Kook

    2016-07-01

    Lysosomes are cellular organelles containing diverse classes of catabolic enzymes that are implicated in diverse cellular processes including phagocytosis, autophagy, lipid transport, and aging. Lysosome-associated membrane proteins (LAMP-1 and LAMP-2) are major glycoproteins important for maintaining lysosomal integrity, pH, and catabolism. LAMP-1 and LAMP-2 are constitutively expressed in Salmonella-infected cells and are recruited to Salmonella-containing vacuoles (SCVs) as well as Salmonella-induced filaments (Sifs) that promote the survival and proliferation of the Salmonella. LAMP-3, also known as DC-LAMP/CD208, is a member of the LAMP family of proteins, but its role during Salmonella infection remains unclear. DNA microarray analysis identified LAMP-3 as one of the genes responding to LPS stimulation in THP-1 macrophage cells. Subsequent analyses reveal that LPS and Salmonella induced the expression of LAMP-3 at both the transcriptional and translational levels. Confocal Super resolution N-SIM imaging revealed that LAMP-3, like LAMP-2, shifts its localization from the cell surface to alongside Salmonella. Knockdown of LAMP-3 by specific siRNAs decreased the number of Salmonella recovered from the infected cells. Therefore, we conclude that LAMP-3 is induced by Salmonella infection and recruited to the Salmonella pathogen for intracellular proliferation.

  10. LAMP-3 (Lysosome-Associated Membrane Protein 3) Promotes the Intracellular Proliferation of Salmonella typhimurium

    PubMed Central

    Lee, Eun-Ju; Park, Kwan-Sik; Jeon, In-Sook; Choi, Jae-Woon; Lee, Sang-Jeon; Choy, Hyun E.; Song, Ki-Duk; Lee, Hak-Kyo; Choi, Joong-Kook

    2016-01-01

    Lysosomes are cellular organelles containing diverse classes of catabolic enzymes that are implicated in diverse cellular processes including phagocytosis, autophagy, lipid transport, and aging. Lysosome-associated membrane proteins (LAMP-1 and LAMP-2) are major glycoproteins important for maintaining lysosomal integrity, pH, and catabolism. LAMP-1 and LAMP-2 are constitutively expressed in Salmonella-infected cells and are recruited to Salmonella-containing vacuoles (SCVs) as well as Salmonella-induced filaments (Sifs) that promote the survival and proliferation of the Salmonella. LAMP-3, also known as DC-LAMP/CD208, is a member of the LAMP family of proteins, but its role during Salmonella infection remains unclear. DNA microarray analysis identified LAMP-3 as one of the genes responding to LPS stimulation in THP-1 macrophage cells. Subsequent analyses reveal that LPS and Salmonella induced the expression of LAMP-3 at both the transcriptional and translational levels. Confocal Super resolution N-SIM imaging revealed that LAMP-3, like LAMP-2, shifts its localization from the cell surface to alongside Salmonella. Knockdown of LAMP-3 by specific siRNAs decreased the number of Salmonella recovered from the infected cells. Therefore, we conclude that LAMP-3 is induced by Salmonella infection and recruited to the Salmonella pathogen for intracellular proliferation. PMID:27329040

  11. LAMP-2C Inhibits MHC Class II Presentation of Cytoplasmic Antigens by Disrupting Chaperone-Mediated Autophagy.

    PubMed

    Pérez, Liliana; McLetchie, Shawna; Gardiner, Gail J; Deffit, Sarah N; Zhou, Delu; Blum, Janice S

    2016-03-15

    Cells use multiple autophagy pathways to sequester macromolecules, senescent organelles, and pathogens. Several conserved isoforms of the lysosome-associated membrane protein-2 (LAMP-2) regulate these pathways influencing immune recognition and responses. LAMP-2A is required for chaperone-mediated autophagy (CMA), which promotes Ag capture and MHC class II (MHCII) presentation in B cells and signaling in T cells. LAMP-2B regulates lysosome maturation to impact macroautophagy and phagocytosis. Yet, far less is known about LAMP-2C function. Whereas LAMP2A and LAMP2B mRNA were broadly detected in human tissues, LAMP2C expression was more limited. Transcripts for the three LAMP2 isoforms increased with B cell activation, although specific gene induction varied depending on TLR versus BCR engagement. To examine LAMP-2C function in human B cells and specifically its role in Ag presentation, we used ectopic gene expression. Increased LAMP-2C expression in B cells did not alter MHCII expression or invariant chain processing, but did perturb cytoplasmic Ag presentation via CMA. MHCII presentation of epitopes from exogenous and membrane Ags was not affected by LAMP-2C expression in B cells. Similarly, changes in B cell LAMP-2C expression did not impact macroautophagy. The gene expression of other LAMP2 isoforms and proteasome and lysosomal proteases activities were unperturbed by LAMP-2C ectopic expression. LAMP-2C levels modulated the steady-state expression of several cytoplasmic proteins that are targeted for degradation by CMA and diminished peptide translocation via this pathway. Thus, LAMP-2C serves as a natural inhibitor of CMA that can selectively skew MHCII presentation of cytoplasmic Ags. Copyright © 2016 by The American Association of Immunologists, Inc.

  12. LAMP-2C inhibits MHC class II presentation of cytoplasmic antigens by disrupting chaperone-mediated autophagy

    PubMed Central

    Pérez, Liliana; McLetchie, Shawna; Gardiner, Gail J.; Deffit, Sarah N.; Zhou, Delu; Blum, Janice S.

    2016-01-01

    Cells utilize multiple autophagy pathways to sequester macromolecules, senescent organelles, and pathogens. Several conserved isoforms of the lysosome-associated membrane protein (LAMP)-2 regulate these pathways influencing immune recognition and responses. LAMP-2A is required for chaperone-mediated autophagy (CMA) which promotes Ag capture and MHC class II (MHCII) presentation in B cells and signaling in T cells. LAMP-2B regulates lysosome maturation to impact macroautophagy (MA) and phagocytosis. Yet, far less is known about LAMP-2C function. While LAMP2A and LAMP2B mRNA were broadly detected in human tissues, LAMP2C expression was more limited. Transcripts for the three LAMP2 isoforms increased with B cell activation, although specific gene induction varied depending on TLR versus BCR engagement. To examine LAMP-2C function in human B cells and specifically its role in Ag presentation, ectopic gene expression was used. Increased LAMP-2C expression in B cells did not alter MHCII expression or invariant chain processing, but did perturb cytoplasmic Ag presentation via CMA. MHCII presentation of epitopes from exogenous and membrane Ags was not affected by LAMP-2C expression in B cells. Similarly, changes in B cell LAMP-2C expression did not impact MA. The gene expression of other LAMP2 isoforms as well as the proteasome and lysosomal proteases activities were unperturbed by LAMP-2C ectopic expression. LAMP-2C levels modulated the steady-state expression of several cytoplasmic proteins which are targeted for degradation by CMA and diminished peptide translocation via this pathway. Thus, LAMP-2C serves as a natural inhibitor of CMA which can selectively skew MHCII presentation of cytoplasmic Ags. PMID:26856698

  13. Segregated tandem filter for enhanced conversion efficiency in a thermophotovoltaic energy conversion system

    DOEpatents

    Brown, E.J.; Baldasaro, P.F.; Dziendziel, R.J.

    1997-12-23

    A filter system to transmit short wavelength radiation and reflect long wavelength radiation for a thermophotovoltaic energy conversion cell comprises an optically transparent substrate segregation layer with at least one coherent wavelength in optical thickness; a dielectric interference filter deposited on one side of the substrate segregation layer, the interference filter being disposed toward the source of radiation, the interference filter including a plurality of alternating layers of high and low optical index materials adapted to change from transmitting to reflecting at a nominal wavelength {lambda}{sub IF} approximately equal to the bandgap wavelength {lambda}{sub g} of the thermophotovoltaic cell, the interference filter being adapted to transmit incident radiation from about 0.5{lambda}{sub IF} to {lambda}{sub IF} and reflect from {lambda}{sub IF} to about 2{lambda}{sub IF}; and a high mobility plasma filter deposited on the opposite side of the substrate segregation layer, the plasma filter being adapted to start to become reflecting at a wavelength of about 1.5{lambda}{sub IF}. 10 figs.

  14. On the ordinary quiver of the symmetric group over a field of characteristic 2

    NASA Astrophysics Data System (ADS)

    Martin, Stuart; Russell, Lee

    1997-11-01

    Let [fraktur S]n and [fraktur A]n denote the symmetric and alternating groups of degree n[set membership][open face N] respectively. Let p be a prime number and let F be an arbitrary field of characteristic p. We say that a partition of n is p-regular if no p (non-zero) parts of it are equal; otherwise we call it p-singular. Let S[lambda]F denote the Specht module corresponding to [lambda]. For [lambda] a p-regular partition of n let D[lambda]F denote the unique irreducible top factor of S[lambda]F. Denote by [Delta][lambda]F =D[lambda]F [downward arrow][fraktur A]n its restriction to [fraktur A]n. Recall also that, over F, the ordinary quiver of the modular group algebra FG is a finite directed graph defined as follows: the vertices are labelled by the set of all simple FG-modules, L1, [ctdot], Lr, and the number of arrows from Li to Lj equals dimFExtFG(Li, Lj). The quiver gives important information about the block structure of G.

  15. The anomalous C 4 intensity ratio in symbiotic stars

    NASA Technical Reports Server (NTRS)

    Michalitsianos, A. G.; Kafatos, M.; Fahey, R. P.

    1988-01-01

    The C IV lambda lambda 1548.2,1550.8 resonance doublet in a symbiotic stars was shown to exhibit anomalous line intensity ratios in which I (lambda 1548.2)/I(lambda 1550.8) less than 1, or less than the optically-thick limit of unity. The R Aquarii-central HII region and RX Puppis exhibit this phenomena. The I(lambda 1548.2)/I(lambda 1550.8) ratio in RX Puppis is found to vary inversely with the total C IV line intensity, and with the FES-visual light, as the object declined over a 5 yr period following a brightening in UV and optical emission which peaked in 1982. This doublet intensity behavior could be explained by a wind which has a narrow velocity range of 600 approx. less than sup v wind approx. less than 1000 km/sec, or by the pumping of the Fe II (mul. 45.01) transition a sup 4 F sub 9/2 - y sup 4 H(o) sub 11/2 by C IV lambda 1548.2, which effectively scatters C IV photons into the Fe II spectrum in these objects.

  16. Absorption of {Lambda}(1520) hyperons in photon-nucleus collisions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paryev, E. Ya.

    2012-12-15

    In the framework of the nuclear spectral function approach for incoherent primary photon-nucleon and secondary pion-nucleon production processes we study the inclusive {Lambda}(1520)-hyperon production in the interaction of 2-GeV photons with nuclei. In particular, the A and momentum dependences of the absolute and relative {Lambda}(1520)-hyperon yields are investigated in two scenarios for its in-medium width. Our model calculations show that the pion-nucleon production channel contributes appreciably to the {Lambda}(1520) creation at intermediate momenta both in light and heavy nuclei in the chosen kinematics and, hence, has to be taken into consideration on close examination of the dependences of the {Lambda}(1520)-hyperonmore » yields on the target mass number with the aim to get information on its width in the medium. They also demonstrate that the A and momentum dependences of the absolute and relative {Lambda}(1520)-hyperon production cross sections at incident energy of interest are markedly sensitive to the {Lambda}(1520) in-medium width, which means that these observables may be an important tool to determine the above width.« less

  17. Different sensing modes of fluoride and acetate based on a calix[4]arene with 25,27-bistriazolylmethylpyrenylacetamides.

    PubMed

    Hung, Hao-Chih; Chang, Yung-Yu; Luo, Liyang; Hung, Chen-Hsiung; Diau, Eric Wei-Guang; Chung, Wen-Sheng

    2014-02-01

    25,27-Bis{1'-N-(1-pyrenyl)-aminocarbonylmethyl-1H-[1',2',3']tri-azolyl-4'-methoxy}-26,28-dihydroxycalix[4]arene, 4, is synthesized as a fluorescent chemosensor for the selective detection of both anions and ion pairs in MeCN. Sensor 4 uses bis-triazoles as ligands to bind a metal ion, bis-amides and bis-triazoles as the sites to recognize anions, and pyrenes as fluorophores. Among eight anions screened, chemosensor 4 showed a marked fluorescence change toward F(-), H2PO4(-) and AcO(-), but 4 responded to each anion in a distinct way. In the presence of F(-) at low concentrations, the dynamic excimer emission of compound 4 at λ(max) 482 nm was quenched, but an emission at λ(max) 472 nm appeared at large doses of F(-). A control compound 6 showed very similar red shifts in the UV-vis and excitation spectra as 4 did, and its 472 nm emission band grew as the fluoride doses increased. Thus, the growth of the 472 nm emission of 4 and 6 in the presence of excess F(-) may be because strong H-bonding interactions of amido protons with F(-) favoured the formation of pyrene dimers in the ground state with charge transfer characteristics. The addition of H2PO4(-), unlike F(-), to a solution of 4 showed an enhanced monomer emission but a decreased excimer emission (λ(max) 482 nm). Adding AcO(-) to 4 produced a systematic change from a dynamic excimer (λ(max) 482 nm) to λ(max) 472 nm but with very little change in the UV-vis spectrum. Time-resolved fluorescence measurements on compound 6 with F(-) and AcO(-) confirmed that the 472 nm emission band mainly came from static excimers for the former, but was partly from a dynamic excimer for the latter because it contained a growth component in the fluorescence decay traces. Without pre-treatment with an anion, chemosensor 4 showed recognition of only metal ions Cu(2+), Hg(2+) and Cr(3+), but it became sensitive to Ag(+) when it was pretreated with fluoride.

  18. 49 CFR 393.22 - Combination of lighting devices and reflectors.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical...) Prohibited combinations. (1) A turn signal lamp must not be combined optically with either a head lamp or... the turn signal lamp. (2) A turn signal lamp must not be combined optically with a stop lamp unless...

  19. Laser effect on the 248 nm KrF transition using heavy ion beam pumping

    NASA Astrophysics Data System (ADS)

    Adonin, A.; Jacoby, J.; Turtikov, V.; Fertman, A.; Golubev, A.; Hoffmann, D. H. H.; Ulrich, A.; Varentsov, D.; Wieser, J.

    2007-07-01

    In December 2005 the first successful operation of a UV excimer laser pumped with a heavy ion beam was demonstrated at GSI. It was the first experiment in which the specific power deposition was sufficient to overcome laser threshold for a UV excimer scheme. The well known KrF* excimer laser line at λ=248 nm has been chosen for this experiment, because the wavelength is short, but still in the range of usual optical diagnostic tools and the emitted light can propagate in air without attenuation. A bunch compressed U+73238 beam with a particle energy of 250 MeV/u and about 110 ns pulse duration (FWHM) was used for this experiment. Single pulses of a beam intensity up to 2.5×109 particles per bunch were focused into the laser cell along the cavity axis. Compact spectrometers, high speed UV-photodiodes and gated CCD-cameras were used for diagnostics of the spontaneous and stimulated emission. As a main result of the experiment laser effect on the 248 nm KrF* excimer laser line has been obtained and verified by temporal and spectral narrowing of the laser line as well as the threshold behaviour and exponential growth of intensity with increasing pumping power. In summary it could be shown that the pumping power of the heavy ion beam at GSI is now sufficient to pump short wavelength lasers. It is planned to extend laser experiments in near future to the VUV range of the spectrum (λ<200 nm).

  20. Spectroscopy of the neutron-rich hypernucleus He Λ 7 from electron scattering

    DOE PAGES

    Gogami, T.; Chen, C.; Kawama, D.; ...

    2016-08-12

    Here, the missing mass spectroscopy of themore » $$^{7}_{\\Lambda}$$He hypernucleus was performed, using the $$^{7}$$Li$$(e,e^{\\prime}K^{+})^{7}_{\\Lambda}$$He reaction at the Thomas Jefferson National Accelerator Facility Hall C. The $$\\Lambda$$ binding energy of the ground state (1/2$$^{+}$$) was determined with a smaller error than that of the previous measurement, being $$B_{\\Lambda}$$ = 5.55 $$\\pm$$ 0.10(stat.) $$\\pm$$ 0.11(sys.) MeV. The experiment also provided new insight into charge symmetry breaking in p-shell hypernuclear systems. Finally, a peak at $$B_{\\Lambda}$$ = 3.65 $$\\pm$$ 0.20(stat.) $$\\pm$$ 0.11(sys.) MeV was observed and assigned as a mixture of 3/2$$^{+}$$ and 5/2$$^{+}$$ states, confirming the "gluelike" behavior of $$\\Lambda$$, which makes an unstable state in $$^{6}$$He stable against neutron emission.« less

  1. A 2-lambda laser-induced flurorescence field instrument for ground-based and airborne measurements of atmospheric OH

    NASA Technical Reports Server (NTRS)

    Rodgers, M. O.; Bradshaw, J. D.; Sandholm, S. T.; Kesheng, S.; Davis, D. D.

    1985-01-01

    A number of techniques have been proposed for detecting atmospheric OH radicals. Of these, the laser-induced fluorescence (LIF) technique has been used by the largest number of investigators. One of the problems arising in connection with the implementation of this technique is related to the perturbing effect of the UV (lambda approximately 282 nm) laser beam used for OH monitoring, while another problem relates to signal extraction. Several new LIF approaches have been or are currently under development with the objective to bring both problems under control. The present paper deals with the experimental features of one of these new approaches. The considered approach is referred to as 2-lambda laser-induced fluorescence (2-lambda LIF). It is shown that the 2-lambda LIF system provides significant advantages over earlier 1-lambda LIF OH measurement instruments operating at ambient pressure.

  2. Hybrid-Lambda: simulation of multiple merger and Kingman gene genealogies in species networks and species trees.

    PubMed

    Zhu, Sha; Degnan, James H; Goldstien, Sharyn J; Eldon, Bjarki

    2015-09-15

    There has been increasing interest in coalescent models which admit multiple mergers of ancestral lineages; and to model hybridization and coalescence simultaneously. Hybrid-Lambda is a software package that simulates gene genealogies under multiple merger and Kingman's coalescent processes within species networks or species trees. Hybrid-Lambda allows different coalescent processes to be specified for different populations, and allows for time to be converted between generations and coalescent units, by specifying a population size for each population. In addition, Hybrid-Lambda can generate simulated datasets, assuming the infinitely many sites mutation model, and compute the F ST statistic. As an illustration, we apply Hybrid-Lambda to infer the time of subdivision of certain marine invertebrates under different coalescent processes. Hybrid-Lambda makes it possible to investigate biogeographic concordance among high fecundity species exhibiting skewed offspring distribution.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deur, Alexandre; Brodsky, Stanley J.; de Téramond, Guy F.

    Here, the recent determination of themore » $$\\beta$$--function of the QCD running coupling $$\\alpha_{\\overline{MS}}(Q^2)$$ to five-loops, provides a verification of the convergence of a novel method for determining the fundamental QCD parameter $$\\Lambda_s$$ based on the Light-Front Holographic approach to nonperturbative QCD. The new 5-loop analysis, together with improvements in determining the holographic QCD nonperturbative scale parameter $$\\kappa$$ from hadronic spectroscopy, leads to an improved precision of the value of $$\\Lambda_s$$ in the $${\\overline{MS}}$$ scheme close to a factor of two; we find $$\\Lambda^{(3)}_{\\overline{MS}}=0.339\\pm0.019$$ GeV for $$n_{f}=3$$, in excellent agreement with the world average, $$\\Lambda_{\\overline{MS}}^{(3)}=0.332\\pm0.017$$ GeV. Lastly, we also discuss the constraints imposed on the scale dependence of the strong coupling in the nonperturbative domain by superconformal quantum mechanics and its holographic embedding in anti-de Sitter space.« less

  4. Simultaneous display of two large proteins on the head and tail of bacteriophage lambda.

    PubMed

    Pavoni, Emiliano; Vaccaro, Paola; D'Alessio, Valeria; De Santis, Rita; Minenkova, Olga

    2013-09-30

    Consistent progress in the development of bacteriophage lambda display platform as an alternative to filamentous phage display system was achieved in the recent years. The lambda phage has been engineered to display efficiently multiple copies of peptides or even large protein domains providing a powerful tool for screening libraries of peptides, proteins and cDNA. In the present work we describe an original method for dual display of large proteins on the surface of lambda particles. An anti-CEA single-chain antibody fragment and green fluorescent protein or alkaline phosphatase were simultaneously displayed by engineering both gpD and gpV lambda proteins. Here we show that such modified phage particles can be used for the detection of target molecules in vitro and in vivo. Dual expression of functional moieties on the surface of the lambda phage might open the way to generation of a new class of diagnostic and therapeutic targeted nanoparticles.

  5. Primary Dendrite Arm Spacings in Al-7Si Alloy Directionally Solidified on the International Space Station

    NASA Technical Reports Server (NTRS)

    Angart, Samuel; Lauer, Mark; Poirier, David; Tewari, Surendra; Rajamure, Ravi; Grugel, Richard

    2015-01-01

    Samples from directionally solidified Al- 7 wt. % Si have been analyzed for primary dendrite arm spacing (lambda) and radial macrosegregation. The alloy was directionally solidified (DS) aboard the ISS to determine the effect of mitigating convection on lambda and macrosegregation. Samples from terrestrial DS-experiments thermal histories are discussed for comparison. In some experiments, lambda was measured in microstructures that developed during the transition from one speed to another. To represent DS in the presence of no convection, the Hunt-Lu model was used to represent diffusion controlled growth under steady-state conditions. By sectioning cross-sections throughout the entire length of a solidified sample, lambda was measured and calculated using the model. During steady-state, there was reasonable agreement between the measured and calculated lambda's in the space-grown samples. In terrestrial samples, the differences between measured and calculated lambda's indicated that the dendritic growth was influenced by convection.

  6. Measurement of the Lambdab0 lifetime in Lambdab0 --> Lambdac+pi- decays in pp collisions at square root of s = 1.96 TeV.

    PubMed

    Aaltonen, T; Adelman, J; Alvarez González, B; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Apresyan, A; Arisawa, T; Artikov, A; Asaadi, J; Ashmanskas, W; Attal, A; Aurisano, A; Azfar, F; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartos, P; Bauer, G; Beauchemin, P-H; Bedeschi, F; Beecher, D; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Binkley, M; Bisello, D; Bizjak, I; Blair, R E; Blocker, C; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bortoletto, D; Boudreau, J; Boveia, A; Brau, B; Bridgeman, A; Brigliadori, L; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Byrum, K L; Cabrera, S; Calancha, C; Camarda, S; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, K; Chokheli, D; Chou, J P; Chung, K; Chung, W H; Chung, Y S; Chwalek, T; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Compostella, G; Convery, M E; Conway, J; Corbo, M; Cordelli, M; Cox, C A; Cox, D J; Crescioli, F; Cuenca Almenar, C; Cuevas, J; Culbertson, R; Cully, J C; Dagenhart, D; Datta, M; Davies, T; de Barbaro, P; De Cecco, S; Deisher, A; De Lorenzo, G; Dell'Orso, M; Deluca, C; Demortier, L; Deng, J; Deninno, M; d'Errico, M; Di Canto, A; di Giovanni, G P; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Donati, S; Dong, P; Dorigo, T; Dube, S; Ebina, K; Elagin, A; Erbacher, R; Errede, D; Errede, S; Ershaidat, N; Eusebi, R; Fang, H C; Farrington, S; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Ferrazza, C; Field, R; Flanagan, G; Forrest, R; Frank, M J; Franklin, M; Freeman, J C; Furic, I; Gallinaro, M; Galyardt, J; Garberson, F; Garcia, J E; Garfinkel, A F; Garosi, P; Gerberich, H; Gerdes, D; Gessler, A; Giagu, S; Giakoumopoulou, V; Giannetti, P; Gibson, K; Gimmell, J L; Ginsburg, C M; Giokaris, N; Giordani, M; Giromini, P; Giunta, M; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gresele, A; Grinstein, S; Grosso-Pilcher, C; Group, R C; Grundler, U; Guimaraes da Costa, J; Gunay-Unalan, Z; Haber, C; Hahn, S R; Halkiadakis, E; Han, B-Y; Han, J Y; Happacher, F; Hara, K; Hare, D; Hare, M; Harr, R F; Hartz, M; Hatakeyama, K; Hays, C; Heck, M; Heinrich, J; Herndon, M; Heuser, J; Hewamanage, S; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Hou, S; Houlden, M; Hsu, S-C; Hughes, R E; Hurwitz, M; Husemann, U; Hussein, M; Huston, J; Incandela, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeon, E J; Jha, M K; Jindariani, S; Johnson, W; Jones, M; Joo, K K; Jun, S Y; Jung, J E; Junk, T R; Kamon, T; Kar, D; Karchin, P E; Kato, Y; Kephart, R; Ketchum, W; Keung, J; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, H W; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kimura, N; Kirsch, L; Klimenko, S; Kondo, K; Kong, D J; Konigsberg, J; Korytov, A; Kotwal, A V; Kreps, M; Kroll, J; Krop, D; Krumnack, N; Kruse, M; Krutelyov, V; Kuhr, T; Kulkarni, N P; Kurata, M; Kwang, S; Laasanen, A T; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; LeCompte, T; Lee, E; Lee, H S; Lee, J S; Lee, S W; Leone, S; Lewis, J D; Lin, C-J; Linacre, J; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, C; Liu, T; Lockyer, N S; Loginov, A; Lovas, L; Lucchesi, D; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lys, J; Lysak, R; MacQueen, D; Madrak, R; Maeshima, K; Makhoul, K; Maksimovic, P; Malde, S; Malik, S; Manca, G; Manousakis-Katsikakis, A; Margaroli, F; Marino, C; Marino, C P; Martin, A; Martin, M S; Martin, V; Martínez, M; Martínez-Ballarín, R; Mastrandrea, P; Mathis, M; Mattson, M E; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Menzione, A; Mesropian, C; Miao, T; Mietlicki, D; Miladinovic, N; Miller, R; Mills, C; Milnik, M; Mitra, A; Mitselmakher, G; Miyake, H; Moed, S; Moggi, N; Mondragon, M N; Moon, C S; Moore, R; Morello, M J; Morlock, J; Movilla Fernandez, P; Mülmenstädt, J; Mukherjee, A; Muller, Th; Mumford, R; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Naganoma, J; Nakamura, K; Nakano, I; Napier, A; Nett, J; Neu, C; Neubauer, M S; Neubauer, S; Nielsen, J; Nodulman, L; Norman, M; Norniella, O; Nurse, E; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Osterberg, K; Pagan Griso, S; Pagliarone, C; Palencia, E; Papadimitriou, V; Papaikonomou, A; Paramanov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Peiffer, T; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Pianori, E; Pinera, L; Pitts, K; Plager, C; Pondrom, L; Potamianos, K; Poukhov, O; Prokoshin, F; Pronko, A; Ptohos, F; Pueschel, E; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Renton, P; Renz, M; Rescigno, M; Richter, S; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rodriguez, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Roy, P; Ruiz, A; Russ, J; Rusu, V; Rutherford, B; Saarikko, H; Safonov, A; Sakumoto, W K; Santi, L; Sartori, L; Sato, K; Savoy-Navarro, A; Schlabach, P; Schmidt, A; Schmidt, E E; Schmidt, M A; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Sexton-Kennedy, L; Sforza, F; Sfyrla, A; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shiraishi, S; Shochet, M; Shon, Y; Shreyber, I; Simonenko, A; Sinervo, P; Sisakyan, A; Slaughter, A J; Slaunwhite, J; Sliwa, K; Smith, J R; Snider, F D; Snihur, R; Soha, A; Somalwar, S; Sorin, V; Squillacioti, P; Stanitzki, M; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Strycker, G L; Suh, J S; Sukhanov, A; Suslov, I; Taffard, A; Takashima, R; Takeuchi, Y; Tanaka, R; Tang, J; Tecchio, M; Teng, P K; Thom, J; Thome, J; Thompson, G A; Thomson, E; Tipton, P; Ttito-Guzmán, P; Tkaczyk, S; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Tourneur, S; Trovato, M; Tsai, S-Y; Tu, Y; Turini, N; Ukegawa, F; Uozumi, S; van Remortel, N; Varganov, A; Vataga, E; Vázquez, F; Velev, G; Vellidis, C; Vidal, M; Vila, I; Vilar, R; Vogel, M; Volobouev, I; Volpi, G; Wagner, P; Wagner, R G; Wagner, R L; Wagner, W; Wagner-Kuhr, J; Wakisaka, T; Wallny, R; Wang, S M; Warburton, A; Waters, D; Weinberger, M; Weinelt, J; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Wilbur, S; Williams, G; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Wolfe, H; Wright, T; Wu, X; Würthwein, F; Yagil, A; Yamamoto, K; Yamaoka, J; Yang, U K; Yang, Y C; Yao, W M; Yeh, G P; Yi, K; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanetti, A; Zeng, Y; Zhang, X; Zheng, Y; Zucchelli, S

    2010-03-12

    We report a measurement of the lifetime of the Lambda(b)(0) baryon in decays to the Lambda(c)(+)pi(-) final state in a sample corresponding to 1.1 fb(-1) collected in pp collisions at square root of s = 1.96 TeV by the CDF II detector at the Tevatron collider. Using a sample of about 3000 fully reconstructed Lambda(b)(0) events we measure tau(Lambda(b)(0)) = 1.401 +/- 0.046(stat) +/- 0.035(syst) ps (corresponding to ctau(Lambda(b)(0)) = 420.1 +/- 13.7(stat) +/- 10.6(syst) microm, where c is the speed of light). The ratio of this result and the world average B(0) lifetime yields tau(Lambda(b)(0))/tau(B(0)) = 0.918 +/- 0.038 (stat) and (syst), in good agreement with recent theoretical predictions.

  7. {Lambda}K*{Lambda}(1116) photoproduction and nucleon resonances

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Sang-Ho; Kim, Hyun-Chul; Nam, Seung-il

    2011-10-21

    In this presentation, we report our recent studies on the {Lambda}K*{Lambda}(1116) photoproduction off the proton target, using the tree-level Born approximation, via the effective Lagrangian approach. In addition, we include the nine (three- or four-star confirmed) nucleon resonances below the threshold {radical}(s{sub th}){approx_equal}2008 MeV, to interpret the discrepancy between the experiment and previous theoretical studies, in the vicinity of the threshold region. From the numerical studies, we observe that the S{sub 11}(1535) and S11(1650) play an important role for the cross-section enhancement near the {radical}(s{sub th}). It also turns out that, in order to reproduce the data, we have themore » vector coupling constants gK*S{sub 11}(1535){Lambda} = (7.0{approx}9.0) and gK*S{sub 11}(1650){Lambda} (5.0{approx}6.0).« less

  8. Spectroscopic studies and structure of 3-methoxy-2 -[(2,4,4,6,6-pentachloro-1,3,5,2{lambda}{sup 5},4{lambda}{sup 5},6{lambda}{sup 5}-triazatriphosphin-2-yl)oxy] benzaldehyde

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oezay, H.; Yildiz, M., E-mail: myildiz@comu.edu.tr; Uenver, H.

    2013-01-15

    The compound called 3-methoxy-2- [(2,4,4,6,6-pentachloro-1,3,5,2{lambda}{sup 5},4{lambda}{sup 5},6{lambda}{sup 5}-triazatriphosphin-2-yl)oxy] benzaldehyde has been synthesized from the reaction of 2-hydroxy-3-methoxybenzaldehyde with hexachlorocyclotriphosphazene. It has been characterized by elemental analysis, MS, IR, {sup 1}H NMR, {sup 13}C NMR, {sup 31}P NMR and UV-visible spectroscopic techniques. The structure of the title compound has been determind by X-ray analysis. Crystals are orthorhombic, space group P2{sub 1}2{sub 1}2{sub 1}, Z = 4, a = 7.705(1), b = 12.624(1), c = 17.825(2) A, R{sub 1} = 0.0390 and wR{sub 2} = 0.1074 [I > 2{sigma}(I)], respectively.

  9. Characterization and recovery of mercury from spent fluorescent lamps.

    PubMed

    Jang, Min; Hong, Seung Mo; Park, Jae K

    2005-01-01

    Fluorescent lamps rely on mercury as the source of ultraviolet radiation for the production of visible light. Partitioning of mercury among vapor phase, loose phosphor powders produced during breaking and washing steps, glass matrices, phosphor powders attached on the glass and aluminum end caps was examined from simulated laboratory lamp recycling tests for different types of spent and new fluorescent lamps. Mercury concentrations in lamp glasses taken from commercial lamp recyclers were also analyzed for comparison with the simulated results of spent and new lamps of different types. The mercury content of the glass from spent lamps was highly variable depending on the lamp type and manufacturer; the median values of the mercury concentration in glasses for spent 26- (T8) and 38-mm (T12) diameter fluorescent lamps were approximately 30 and 45 microg/g, respectively. The average mercury concentration of samples taken from recycler A was 29.6 microg/g, which was about 64% of median value measured from the spent T12 lamps. Over 94% of total mercury in lamps remained either as a component of phosphor powders attached inside the lamp or in glass matrices. New T12 lamps had a higher partitioning percentage of elemental mercury in the vapor phase (0.17%) than spent T12 lamps (0.04%), while spent lamps had higher partitioning percentages of mercury resided on end-caps and phosphor powders detached from the breaking and washing steps. The TCLP values of simulated all lamp-glasses and samples obtained from recyclers were higher than the limit of LDR standard (0.025 mg/L). After investigating acid treatment and high temperature treatment as mercury reclamation techniques, it was found that heating provided the most effective mercury capture. Although the initial mercury concentrations of individual sample were different, the mercury concentrations after 1 h exposure at 100 degrees C were below 4 mug/g for all samples (i.e., <1% remaining). Therefore, it is recommended that heating be used for recovering mercury from spent fluorescent lamps.

  10. Longitudinal diffusion tensor magnetic resonance imaging study of radiation-induced white matter damage in a rat model.

    PubMed

    Wang, Silun; Wu, Ed X; Qiu, Deqiang; Leung, Lucullus H T; Lau, Ho-Fai; Khong, Pek-Lan

    2009-02-01

    Radiation-induced white matter (WM) damage is a major side effect of whole brain irradiation among childhood cancer survivors. We evaluate longitudinally the diffusion characteristics of the late radiation-induced WM damage in a rat model after 25 and 30 Gy irradiation to the hemibrain at 8 time points from 2 to 48 weeks postradiation. We hypothesize that diffusion tensor magnetic resonance imaging (DTI) indices including fractional anisotropy (FA), trace, axial diffusivity (lambda(//)), and radial diffusivity (lambda( perpendicular)) can accurately detect and monitor the histopathologic changes of radiation-induced WM damage, measured at the EC, and that these changes are dose and time dependent. Results showed a progressive reduction of FA, which was driven by reduction in lambda(//) from 4 to 40 weeks postradiation, and an increase in lambda( perpendicular) with return to baseline in lambda(//) at 48 weeks postradiation. Histologic evaluation of irradiated WM showed reactive astrogliosis from 4 weeks postradiation with reversal at 36 weeks, and demyelination, axonal degeneration, and necrosis at 48 weeks postradiation. Moreover, changes in lambda(//) correlated with reactive astrogliosis (P < 0.01) and lambda( perpendicular) correlated with demyelination (P < 0.01). Higher radiation dose (30 Gy) induced earlier and more severe histologic changes than lower radiation dose (25 Gy), and these differences were reflected by the magnitude of changes in lambda(//) and lambda( perpendicular). DTI indices reflected the histopathologic changes of WM damage and our results support the use of DTI as a biomarker to noninvasively monitor radiation-induced WM damage.

  11. Assessment of resistance risk to lambda-cyhalothrin and cross-resistance to four other insecticides in the house fly, Musca domestica L. (Diptera: Muscidae).

    PubMed

    Abbas, Naeem; Shad, Sarfraz Ali

    2015-07-01

    Lambda-cyhalothrin, a sodium channel modulator insecticide, has been used frequently for the control of house flies, Musca domestica L. (Diptera: Muscidae) worldwide, including Pakistan. This experiment was performed to determine the selection and assessment of lambda-cyhalothrin resistance evolution along with four other insecticides. After 26 generations of selection, the lambda-cyhalothrin-selected population developed 445-fold resistance to lambda-cyhalothrin compared to the susceptible population. There was low cross-resistance to bifenthrin and very low cross-resistance to methomyl, imidacloprid, and fipronil in the lambda-cyhalothrin-selected population compared to the field population (G1). Realized heritability (h (2)) of resistance to lambda-cyhalothrin, bifenthrin, methomyl, imidacloprid, and fipronil was 0.07, 0.05, 0.01, 0.08, and 0.08, respectively. The projected rate of resistance development revealed that if 90 % house flies were selected, then a tenfold increase in lethal concentration 50 occurred after 17, 20, 159, 13, and 14 generations for lambda-cyhalothrin (h (2) = 0.07, slope = 2.09), bifenthrin (h (2) = 0.05, slope = 1.73), methomyl (h (2) = 0.01, slope = 2.52), imidacloprid (h (2) = 0.08, slope = 1.89), and fipronil (h (2) = 0.08, slope = 2.03), respectively. The results of our study concluded that the house fly has the potential to develop multiple insecticide resistances following continued selection pressure with lambda-cyhalothrin. This study will be helpful for assisting the development of resistance management strategies.

  12. Size effects of primary/secondary twins on the atomistic deformation mechanisms in hierarchically nanotwinned metals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuan, Fuping; Wu, Xiaolei

    2013-05-28

    A series of large-scale molecular dynamics simulations have been performed to investigate the tensile properties of nanotwinned (NT) copper with hierarchically twinned structures (HTS). For the same grain size d and the same spacing of primary twins {lambda}{sub 1}, the average flow stress first increases as the spacing of secondary twins {lambda}{sub 2} decreases, reaching a maximum at a critical {lambda}{sub 2}, and then decreases as {lambda}{sub 2} becomes even smaller. The smaller the spacing for {lambda}{sub 1}, the smaller the critical spacing for {lambda}{sub 2}. There exists a transition in dominating deformation mechanisms, occurring at a critical spacing ofmore » {lambda}{sub 2} for which strength is maximized. Above the critical spacing of {lambda}{sub 2}, the deformation mechanisms are dominated by the two Hall-Petch type strengthening mechanisms: (a) partial dislocations emitted from grain boundaries (GBs) travel across other GBs and twin boundaries (TBs); (b) partial dislocations emitted from TBs travel across other TBs. Below the critical spacing of {lambda}{sub 2}, the deformation mechanism is dominated by the two softening mechanisms: (a) Partial dislocations emitted from boundaries of the primary twins travel parallel to the TBs of the secondary twins, leading to detwinning of the secondary twins; (b) Boundaries of the primary twins shift entirely, leading to thickening in one part of primary twins and thinning in the other part of primary twins. The present results should provide insights to design the microstructures for reinforcing the mechanical properties in the NT metals with HTS.« less

  13. RECONCILIATION OF WAITING TIME STATISTICS OF SOLAR FLARES OBSERVED IN HARD X-RAYS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aschwanden, Markus J.; McTiernan, James M., E-mail: aschwanden@lmsal.co, E-mail: jimm@ssl.berkeley.ed

    2010-07-10

    We study the waiting time distributions of solar flares observed in hard X-rays with ISEE-3/ICE, HXRBS/SMM, WATCH/GRANAT, BATSE/CGRO, and RHESSI. Although discordant results and interpretations have been published earlier, based on relatively small ranges (<2 decades) of waiting times, we find that all observed distributions, spanning over 6 decades of waiting times ({Delta}t {approx} 10{sup -3}-10{sup 3} hr), can be reconciled with a single distribution function, N({Delta}t) {proportional_to} {lambda}{sub 0}(1 + {lambda}{sub 0{Delta}}t){sup -2}, which has a power-law slope of p {approx} 2.0 at large waiting times ({Delta}t {approx} 1-1000 hr) and flattens out at short waiting times {Delta}t {approx}

  14. Controllable Change of Photoluminescence Spectra of Silicone Rubber Modified by 193 nm ArF Excimer Laser

    NASA Astrophysics Data System (ADS)

    Okoshi, Masayuki; Iyono, Minako; Inoue, Narumi

    2009-12-01

    Photoluminescence spectra of silicone rubber ([SiO(CH3)2]n) photochemically modified by a 193 nm ArF excimer laser was found to be controllable. Compared with the modification in air, the photoluminescence spectra could be blueshifted by the modification in vacuum or the additional irradiation of ArF excimer laser in vacuum after the modification in air. To redshift, on the other hand, the additional irradiation of a 157 nm F2 laser in air after the modification in air, the modification in oxygen gas, or the postannealing after the modification in oxygen gas was effective. The blue and redshifts of the photoluminescence were essentially due to the acceleration of reduction and oxidation reactions of silicone rubber, respectively, because the photoluminescence derives its origin from oxygen deficiency centers and peroxy centers of the silica structure in the modified silicone rubber. On the basis of the spectra changes, colorful light-guiding sheets made of silicone rubber under illumination of a 375 nm light-emitting diode were successfully fabricated for cellular phone use.

  15. Electroluminescence of organic light-emitting diodes consisting of an undoped (pbi)2Ir(acac) phosphorescent layer

    NASA Astrophysics Data System (ADS)

    Lei, Xia; Yu, Junsheng; Zhao, Juan; Jiang, Yadong

    2011-11-01

    The electroluminescence (EL) characteristics of phosphorescent organic light-emitting diodes (OLEDs) with an undoped bis(1,2-dipheny1-1H-benzoimidazole) iridium (acetylacetonate) [(pbi)2Ir(acac)] emissive layer (EML) of various film thicknesses were studied. The results showed that the intensity of green light emission decreased rapidly with the increasing thickness of (pbi)2Ir(acac), which was relevant to the triplet excimer emission. It suggested that the concentration quenching of monomer emission in the undoped (pbi)2Ir(acac) film was mainly due to the formation of triplet excimer and partly due to the triplet-triplet annihilation (TTA) and triplet-polaron annihilation (TPA). A green OLED with a maximum luminance of 26,531 cd/m2, a current efficiency of 36.2 cd/A, and a power efficiency of 32.4 lm/W was obtained, when the triplet excimer emission was eliminated. Moreover, the white OLED with low efficiency roll-off was realized due to the broadened recombination zone and reduced quenching effects in the EML when no electron blocking layer was employed.

  16. Excimers from stable and persistent supramolecular radical-pairs in red/NIR-emitting organic nanoparticles and polymeric films.

    PubMed

    Blasi, Davide; Nikolaidou, Domna M; Terenziani, Francesca; Ratera, Imma; Veciana, Jaume

    2017-03-29

    In this work, the luminescence properties of new materials based on open-shell molecular systems are studied. In particular, we prepared polymeric films and organic nanoparticles (ONPs) doped with triphenylmethyl radical molecules. ONPs exhibit a uniform size distribution, spherical morphology and high colloidal stability. The emission spectrum of low-doped ONP suspensions and low-doped films is very similar to the emission spectrum of TTM in solution, while the luminescence lifetime and the luminescence quantum yield (LQY) are highly increased. Increasing the radical doping leads to a progressive decrease of the LQY and the appearance of a new broad excimeric band at longer wavelengths, both for ONPs and films. Thus, not only the luminescence properties were improved, but also the formation of excimers from stable and persistent supramolecular radical-pairs was observed for the first time. The good stability and luminescence properties with emission in the red-NIR region (650-800 nm), together with the open-shell nature of the emitter, make these free-radical excimer-forming materials promising candidates for optoelectronic and bioimaging applications.

  17. Random noise can help to improve synchronization of excimer laser pulses.

    PubMed

    Mingesz, Róbert; Barna, Angéla; Gingl, Zoltán; Mellár, János

    2016-02-01

    Recently, we have reported on a compact microcontroller-based unit developed to accurately synchronize excimer laser pulses (Mingesz et al. 2012 Fluct. Noise Lett. 11, 1240007 (doi:10.1142/S021947751240007X)). We have shown that dithering based on random jitter noise plus pseudorandom numbers can be used in the digital control system to radically reduce the long-term drift of the laser pulse from the trigger and to improve the accuracy of the synchronization. In this update paper, we present our new experimental results obtained by the use of the delay-controller unit to tune the timing of a KrF excimer laser as an addition to our previous numerical simulation results. The hardware was interfaced to the laser using optical signal paths in order to reduce sensitivity to electromagnetic interference and the control algorithm tested by simulations was applied in the experiments. We have found that the system is able to reduce the delay uncertainty very close to the theoretical limit and performs well in real applications. The simple, compact and flexible system is universal enough to also be used in various multidisciplinary applications.

  18. Identification of a triplet pair intermediate in singlet exciton fission in solution

    PubMed Central

    Stern, Hannah L.; Musser, Andrew J.; Gelinas, Simon; Parkinson, Patrick; Herz, Laura M.; Bruzek, Matthew J.; Anthony, John; Friend, Richard H.; Walker, Brian J.

    2015-01-01

    Singlet exciton fission is the spin-conserving transformation of one spin-singlet exciton into two spin-triplet excitons. This exciton multiplication mechanism offers an attractive route to solar cells that circumvent the single-junction Shockley–Queisser limit. Most theoretical descriptions of singlet fission invoke an intermediate state of a pair of spin-triplet excitons coupled into an overall spin-singlet configuration, but such a state has never been optically observed. In solution, we show that the dynamics of fission are diffusion limited and enable the isolation of an intermediate species. In concentrated solutions of bis(triisopropylsilylethynyl)[TIPS]—tetracene we find rapid (<100 ps) formation of excimers and a slower (∼10 ns) break up of the excimer to two triplet exciton-bearing free molecules. These excimers are spectroscopically distinct from singlet and triplet excitons, yet possess both singlet and triplet characteristics, enabling identification as a triplet pair state. We find that this triplet pair state is significantly stabilized relative to free triplet excitons, and that it plays a critical role in the efficient endothermic singlet fission process. PMID:26060309

  19. Towards excimer-laser-based stereolithography: a rapid process to fabricate rigid biodegradable photopolymer scaffolds

    PubMed Central

    Beke, S.; Anjum, F.; Tsushima, H.; Ceseracciu, L.; Chieregatti, E.; Diaspro, A.; Athanassiou, A.; Brandi, F.

    2012-01-01

    We demonstrate high-resolution photocross-linking of biodegradable poly(propylene fumarate) (PPF) and diethyl fumarate (DEF) using UV excimer laser photocuring at 308 nm. The curing depth can be tuned in a micrometre range by adjusting the total energy dose (total fluence). Young's moduli of the scaffolds are found to be a few gigapascal, high enough to support bone formation. The results presented here demonstrate that the proposed technique is an excellent tool for the fabrication of stiff and biocompatible structures on a micrometre scale with defined patterns of high resolution in all three spatial dimensions. Using UV laser photocuring at 308 nm will significantly improve the speed of rapid prototyping of biocompatible and biodegradable polymer scaffolds and enables its production in a few seconds, providing high lateral and horizontal resolution. This short timescale is indeed a tremendous asset that will enable a more efficient translation of technology to clinical applications. Preliminary cell tests proved that PPF : DEF scaffolds produced by excimer laser photocuring are biocompatible and, therefore, are promising candidates to be applied in tissue engineering and regenerative medicine. PMID:22696484

  20. Update on excimer laser photorefractive keratectomy (PRK) at Cedars-Sinai Medical Center: two-year experience

    NASA Astrophysics Data System (ADS)

    Maguen, Ezra I.; Salz, James J.; Warren, Cathy; Papaioannou, Thanassis; Nesburn, Anthony B.; Macy, Jonathan I.; Hofbauer, John; Grundfest, Warren S.

    1993-06-01

    Our two year experience with excimer laser photorefractive keratectomy for the correction of myopia on 160 eyes of 128 patients is described. All eyes were treated with a VISX Twenty- Twenty excimer laser, with the following parameters: radiant exposure 160 mJ/cm2, frequency 5 Hz, ablation zone diameter 5.0 to 5.5 mm, and stromal ablation rate 0.18 to 0.33 (mu) /pulse. A suction fixation ring was used in all cases either with nitrogen flow (79 eyes) or without nitrogen flow (81 eyes) across the cornea. Follow-up ranged from one month (152 eyes) to 24 months (12 eyes). The results are stable between 3 and 24 months with less than 0.25 D change in the mean postoperative spherical equivalents. In eyes with a follow-up of 6 to 24 months, 77% to 100% were 20/40 or better uncorrected, and 84% to 92% were corrected to within +/- 1 D of emmetropia. Further follow-up is needed to assess the long term safety and efficacy of the procedure.

  1. The Improvement of Electrical Characteristics of Pt/Ti Ohmic Contacts to Ga-Doped ZnO by Homogenized KrF Pulsed Excimer Laser Treatment

    NASA Astrophysics Data System (ADS)

    Oh, Min-Suk

    2018-04-01

    We investigated the effect of KrF excimer laser surface treatment on Pt/Ti ohmic contacts to Ga-doped n-ZnO ( N d = 4.3 × 1017 cm-3). The treatment of the n-ZnO surfaces by laser irradiation greatly improved the electrical characteristics of the metal contacts. The Pt/Ti ohmic layer on the laser-irradiated n-ZnO showed specific contact resistances of 2.5 × 10-4 ˜ 4.8 × 10-4 Ω cm2 depending on the laser energy density and gas ambient, which were about two orders of magnitude lower than that of the as-grown sample, 8.4 × 10-2 Ω cm2. X-ray photoelectron spectroscopy and photoluminescence measurements showed that the KrF excimer laser treatments increased the electron concentration near the surface region of the Ga-doped n-ZnO due to the preferential evaporation of oxygen atoms from the ZnO surface by the laser-induced dissociation of Zn-O bonds.

  2. Alternatives to Goodman and Kruskal's Lambda.

    ERIC Educational Resources Information Center

    Stavig, Gordon R.

    1979-01-01

    Lambda and kappa coefficients of nominal scale association are developed for research hypotheses that involve predictions of modality, agreement, or some theoretically specified configuration. The proposed new coefficient is offered as an alternative to Goodman and Kruskal's lambda. (Author/CTM)

  3. Max Tech and Beyond: High-Intensity Discharge Lamps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scholand, Michael

    High-intensity discharge (HID) lamps are most often found in industrial and commercial applications, and are the light source of choice in street and area lighting, and sports stadium illumination. HID lamps are produced in three types - mercury vapor (MV), high pressure sodium (HPS) and metal halide (MH). Of these, MV and MH are considered white-light sources (although the MV exhibits poor color rendering) and HPS produces a yellow-orange color light. A fourth lamp, low-pressure sodium (LPS), is not a HID lamp by definition, but it is used in similar applications and thus is often grouped with HID lamps. Withmore » the notable exception of MV which is comparatively inefficient and in decline in the US from both a sales and installed stock point of view; HPS, LPS and MH all have efficacies over 100 lumens per watt. The figure below presents the efficacy trends over time for commercially available HID lamps and LPS, starting with MV and LPS in 1930's followed by the development of HPS and MH in the 1960's. In HID lamps, light is generated by creating an electric arc between two electrodes in an arc tube. The particles in the arc are partially ionized, making them electrically conductive, and a light-emitting 'plasma' is created. This arc occurs within the arc tube, which for most HID lamps is enclosed within an evacuated outer bulb that thermally isolates and protects the hot arc tube from the surroundings. Unlike a fluorescent lamp that produces visible light through down-converting UV light with phosphors, the arc itself is the light source in an HID lamp, emitting visible radiation that is characteristic of the elements present in the plasma. Thus, the mixture of elements included in the arc tube is one critical factor determining the quality of the light emitted from the lamp, including its correlated color temperature (CCT) and color rendering index (CRI). Similar to fluorescent lamps, HID lamps require a ballast to start and maintain stable operating conditions, and this necessitates additional power beyond that used by the lamp itself. HID lamps offer important advantages compared to other lighting technologies, making them well suited for certain applications. HID lamps can be very efficient, have long operating lives, are relatively temperature-insensitive and produce a large quantity of light from a small package. For these reasons, HID lamps are often used when high levels of illumination are required over large areas and where operating and maintenance costs must be kept to a minimum. Furthermore, if the installation has a significant mounting height, high-power HID lamps can offer superior optical performance luminaires, reducing the number of lamps required to illuminate a given area. The indoor environments best suited to HID lamps are those with high ceilings, such as those commonly found in industrial spaces, warehouses, large retail spaces, sports halls and large public areas. Research into efficacy improvements for HID lighting technologies has generally followed market demand for these lamps, which is in decline for MV and LPS, has reached a plateau for HPS and is growing for MH. Several manufacturers interviewed for this study indicated that although solid-state lighting was now receiving the bulk of their company's R&D investment, there are still strong HID lamp research programs, which concentrate on MH technologies, with some limited amount of investment in HPS for specific niche applications (e.g., agricultural greenhouses). LPS and MV lamps are no longer being researched or improved in terms of efficacy or other performance attributes, although some consider MH HID lamps to be the next-generation MV lamp. Thus, the efficacy values of commercially available MV, LPS and HPS lamps are not expected to increase in the next 5 to 10 years. MH lamps, and more specifically, ceramic MH lamps are continuing to improve in efficacy as well as light quality, manufacturability and lamp life. Within an HID lamp, the light-producing plasma must be heated to sufficiently high temperatures to achieve high efficiencies, without melting the electrodes or altering the operating conditions of the lamp. The research in ceramic MH has focused on the arc tube, the electrodes and the plasma, resulting in an innovation announced by Philips Lighting in 2009 called the 'unsaturated lamp.' The unsaturated lamp addresses a problem experienced by standard ceramic MH lamps where a pool of liquid salt develops in the arc tube while the lamp is operating. This pool of liquid salt limits the light characteristics of the lamp such as the efficacy and color quality, and reduces lamp lifetime. By making modifications to the arc tube, the pressure and the operating temperature, the unsaturated ceramic MH lamp resolves this issue by keeping all the halide salts in the gaseous phase, even while the lamp is dimming (down to 50%).« less

  4. BAD-LAMP defines a subset of early endocytic organelles in subpopulations of cortical projection neurons.

    PubMed

    David, Alexandre; Tiveron, Marie-Catherine; Defays, Axel; Beclin, Christophe; Camosseto, Voahirana; Gatti, Evelina; Cremer, Harold; Pierre, Philippe

    2007-01-15

    The brain-associated LAMP-like molecule (BAD-LAMP) is a new member of the family of lysosome associated membrane proteins (LAMPs). In contrast to other LAMPs, which show a widespread expression, BAD-LAMP expression in mice is confined to the postnatal brain and therein to neuronal subpopulations in layers II/III and V of the neocortex. Onset of expression strictly parallels cortical synaptogenesis. In cortical neurons, the protein is found in defined clustered vesicles, which accumulate along neurites where it localizes with phosphorylated epitopes of neurofilament H. In primary neurons, BAD-LAMP is endocytosed, but is not found in classical lysosomal/endosomal compartments. Modification of BAD-LAMP by addition of GFP revealed a cryptic lysosomal retention motif, suggesting that the cytoplasmic tail of BAD-LAMP is actively interacting with, or modified by, molecules that promote its sorting away from lysosomes. Analysis of BAD-LAMP endocytosis in transfected HeLa cells provided evidence that the protein recycles to the plasma membrane through a dynamin/AP2-dependent mechanism. Thus, BAD-LAMP is an unconventional LAMP-like molecule and defines a new endocytic compartment in specific subtypes of cortical projection neurons. The striking correlation between the appearance of BAD-LAMP and cortical synatogenesis points towards a physiological role of this vesicular determinant for neuronal function.

  5. The Effects of Lamp Spectral Distribution on Sky Glow over Observatories

    DTIC Science & Technology

    2015-01-01

    overhead sky glow as a function of distance up to 300 km, from a variety of lamp types, including common gas discharge lamps and several types of LED...distance up to 300 km, from a variety of lamp types, in- cluding common gas discharge lamps and several types of LED lamps . We conclude for both...MAR 2015 2. REPORT TYPE 3. DATES COVERED 00-00-2015 to 00-00-2015 4. TITLE AND SUBTITLE The Effects of Lamp Spectral Distribution on Sky Glow

  6. Hepatopancreatic intoxication of lambda cyhalothrin insecticide on albino rats

    PubMed Central

    Elhalwagy, Manal EA; Abd-Alrahman, Sherif H; Nahas, AA; Ziada, Reem M; Mohamady, Aziza H

    2015-01-01

    Background: Despite the known adverse effects of lambda cyhalothrin insecticide, little is known about its hepatopancreatic intoxication effects. The present study was carried out to elucidate sub-chronic effect of Karat 2.5% EC formulation of lambda cyhalothrin on male albino rats. Methods: To explore the effects of exposure to lambda cyhalothrin on rats and its mechanism, low (1/40 of LD50, 5 mg/kg/day) and high dose (1/4 of LD50, 50 mg/kg/day) lambda cyhalothrin were applied to rats via drinking water for 3 months. Blood samples were collected monthly, and the animals were dissected for liver and pancreas’s examination at the end of the experiment. Lambda cyhalothrin administration was associated with the elevation in lipid peroxidation marker, malondialdehyde (MDA), reduction in SH-protein a major marker for antioxidant, as well as basel paraoxonase (PON) in both treated groups throughout the experimental periods. Results: In addition, significant elevations in liver enzymes alanin amino transferase, (ALT), and aspartate amino transferase (AST), as well as plasma acetylcholinesterase (AChE) and glucose level. While, significant reduction in insulin level through the experimental periods. Results of histopathological and histochemical studies showed that lambda cyhalothrin exposure induces liver and pancreatic tissues damage and depletion in glycogen content was pronounced in liver of both treated groups. Conclusions: In conclusion subchronic intoxication with lambda cyhalothrin formulation induced remarkable changes in the examined parameters. PMID:26221269

  7. Hepatopancreatic intoxication of lambda cyhalothrin insecticide on albino rats.

    PubMed

    Elhalwagy, Manal Ea; Abd-Alrahman, Sherif H; Nahas, A A; Ziada, Reem M; Mohamady, Aziza H

    2015-01-01

    Despite the known adverse effects of lambda cyhalothrin insecticide, little is known about its hepatopancreatic intoxication effects. The present study was carried out to elucidate sub-chronic effect of Karat 2.5% EC formulation of lambda cyhalothrin on male albino rats. To explore the effects of exposure to lambda cyhalothrin on rats and its mechanism, low (1/40 of LD50, 5 mg/kg/day) and high dose (1/4 of LD50, 50 mg/kg/day) lambda cyhalothrin were applied to rats via drinking water for 3 months. Blood samples were collected monthly, and the animals were dissected for liver and pancreas's examination at the end of the experiment. Lambda cyhalothrin administration was associated with the elevation in lipid peroxidation marker, malondialdehyde (MDA), reduction in SH-protein a major marker for antioxidant, as well as basel paraoxonase (PON) in both treated groups throughout the experimental periods. In addition, significant elevations in liver enzymes alanin amino transferase, (ALT), and aspartate amino transferase (AST), as well as plasma acetylcholinesterase (AChE) and glucose level. While, significant reduction in insulin level through the experimental periods. Results of histopathological and histochemical studies showed that lambda cyhalothrin exposure induces liver and pancreatic tissues damage and depletion in glycogen content was pronounced in liver of both treated groups. In conclusion subchronic intoxication with lambda cyhalothrin formulation induced remarkable changes in the examined parameters.

  8. Anisotropy of the penetration depth in La2-xSrxCuO4 in underdoped and overdoped regions

    NASA Astrophysics Data System (ADS)

    Zaleski, A. J.; Klamut, J.

    1999-12-01

    We present the results of measurements of the penetration depth anisotropy in pulverized, ceramic La2-xSrxCuO4. The measurements were carried out for x = 0.08, 0.1, 0.125, 0.15 and 0.2. The powdered samples, immersed in wax, were magnetically oriented in a static magnetic field of 10 T. The penetration depth in the a-b plane, icons/Journals/Common/lambda" ALT="lambda" ALIGN="TOP"/>ab, and perpendicular to it, icons/Journals/Common/lambda" ALT="lambda" ALIGN="TOP"/>icons/Journals/Common/perp" ALT="perp" ALIGN="MIDDLE"/>, were derived from alternating-current susceptibility measurements. For underdoped samples they both vary linearly with temperature (for the low-temperature region), while for the samples from the overdoped region the measured points can be fitted by an exponential function. These results support Uemura's picture (Uemura Y J 1997 Physica C 282-287 194) of crossover from Bose-Einstein condensation to a Bardeen-Cooper-Schrieffer mechanism of superconductivity. The penetration depth values extrapolated to T = 0 may be described by a quadratic function of the strontium concentration (for both icons/Journals/Common/lambda" ALT="lambda" ALIGN="TOP"/>ab and icons/Journals/Common/lambda" ALT="lambda" ALIGN="TOP"/>icons/Journals/Common/perp" ALT="perp" ALIGN="MIDDLE"/>). The anisotropy of the penetration depth as a function of the substitution shows a similar dependence to the critical temperature Tc(x).

  9. First-trimester ultrasound determination of chorionicity in twin gestations using the lambda sign: a systematic review and meta-analysis.

    PubMed

    Maruotti, G M; Saccone, G; Morlando, M; Martinelli, P

    2016-07-01

    To evaluate the accuracy of first-trimester sonographic determination of chorionicity in twin gestations using the lambda sign. Electronic databases (MEDLINE, PROSPERO, Scopus, ClinicalTrials.gov, EMBASE, Sciencedirect) were searched from their inception until April 2016. We included only study assessing the accuracy lambda sign in prediction of monochorionicity in the first trimester. Forest plots for pooled sensitivity and specificity with 95% confidence intervals (CI) were generated. In addition, symmetric summary receiver-operating characteristic curves were plotted. The area under the curve (AUC) was also computed to evaluate the overall accuracy of the diagnostic test. Nine studies, including 2292 twins, were analysed. In all of these studies, identification of the lambda sign was used to diagnose chorionicity on real-time B-mode imaging. Twins were classified as monochorionic if there was a single placental mass in the absence of the lambda sign, and dichorionic if there was a single placental mass but the lambda sign was present or the placentas were not adjacent to each other. In all nine studies, placental histology or discordant fetal sex were used to confirm chorionicity. Pooled results from the meta-analysis showed that sensitivity of the presence of the lambda sign in the prediction of dichorionicity was 99% (95% CI 98-100%), and specificity was 95% (95% CI 92-97%). Pooled sensitivity of the absence of the lambda sign in the prediction of monochorionicity was 96% (95% CI 92-98%) and pooled specificity was 99% (95% CI 98-99%). The AUC for diagnostic accuracy was 0.99, and suggested very high diagnostic accuracy. The lambda sign predicts chorionicity with a high degree of accuracy before 14 weeks of gestation. Presence of the lambda sign indicates dichorionicity, and absence of the lambda sign indicates monochorionicity. All hospitals should encourage departments providing ultrasound services to determine chorionicity when examining women with twin pregnancies in the first trimester. As determination of chorionicity is most accurate before 14 weeks when the amnion and chorion have not yet fused, the first-trimester scan in twin pregnancy is paramount. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Simultaneous X-ray, UV, and Optical Variations in lambda ERI (B2e)

    NASA Astrophysics Data System (ADS)

    Smith, M. A.; Murakami, T.; Anandarao, B.

    1996-12-01

    We have carried out a simultaneous observing campaign on the prototypical Be star lambda Eri using ground stations and ROSAT, ASCA, IUE, and Voyager spacecrafts during the week of February-March 1995; a smaller campaign was carried out the following September. In late February lambda Eri showed extraordinary disk-wind activity. ROSAT/HRI monitoring disclosed no large flares such as ROSAT observed in 1991 in lambda Eri. Possible low amplitude fluctuations in the 1995 data occurred at the same time with unusual activity in Hα , HeI lambda 6678, HeII lambda 1640, CIII, and the CIV doublet. The helium line activity suggests that mass ejection occurred at the base of the wind. The strong CIII and CIV lines implies that shock interactions originated in the wind flow. It is not clear that the X-ray fluctuations are directly related to the increases in wind line absorption. Within hours of the mild X-ray flux variations found by ROSAT on February 28, the Voyager UVS observed a ``ringing" that decayed over three 3-hr. cycles. The amplitude of these fluctuations was large (50%) at lambda lambda 950-1100, decreased rapidly with wavelength, and faded to nondetection above lambda 1300. Various considerations indicate that these continuum variations were not due to an instrument pathology in the UVS. Rather, they appear to be due to a time-dependent flux deficit in the lambda lambda 1250 during the minima of these cycles. We outline a scenario in which dense plasma over the star's surface is alternately heated and cooled quasi-periodically to produce the flux changes. Additional examples of this new phenomenon are needed. Amateur astronomers can make a significant contribution to the understanding of flickering in Be star light curves during their outburst phases. We also draw attention to an increase in the emission of the Hα line that occurred at about the same time the FUV ringing started. This increased emission hints that ~ 50,000K plasma near the star's surface can infuence the circumstellar disc some distance away by its increased Lyman continuum flux.

  11. 30 CFR 20.10 - Tests (class 1 and 2 lamps).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Tests (class 1 and 2 lamps). 20.10 Section 20..., AND APPROVAL OF MINING PRODUCTS ELECTRIC MINE LAMPS OTHER THAN STANDARD CAP LAMPS § 20.10 Tests (class 1 and 2 lamps). Such tests will be made as are necessary to prove the adequacy of a lamp or any of...

  12. 30 CFR 20.10 - Tests (class 1 and 2 lamps).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Tests (class 1 and 2 lamps). 20.10 Section 20..., AND APPROVAL OF MINING PRODUCTS ELECTRIC MINE LAMPS OTHER THAN STANDARD CAP LAMPS § 20.10 Tests (class 1 and 2 lamps). Such tests will be made as are necessary to prove the adequacy of a lamp or any of...

  13. 30 CFR 20.10 - Tests (class 1 and 2 lamps).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Tests (class 1 and 2 lamps). 20.10 Section 20..., AND APPROVAL OF MINING PRODUCTS ELECTRIC MINE LAMPS OTHER THAN STANDARD CAP LAMPS § 20.10 Tests (class 1 and 2 lamps). Such tests will be made as are necessary to prove the adequacy of a lamp or any of...

  14. Long-term life testing of Geostationary Operational Environmental Satellite (GOES) encoder lamps

    NASA Technical Reports Server (NTRS)

    Powers, Charles E.

    1992-01-01

    The aging characteristics and lifetimes of tungsten filament encoder lamps were determined as a function of operating voltage and filament material. For pure tungsten and thoria doped (1 pct.) filament lamps, crystal grain growth over the center portion of the filament leads to the ultimate failure of the lamp. The development of notches associated with this grain growth is the cause of lamp burn out. Eventually, one of the notches will 'etch' through the filament, causing it to fail open. For rhenium doped (3 pct.) filament lamps, distortion of the filament leads to the ultimate failure of the lamp. The lifetime of these lamps is about 1 year at an operating voltage of 5.0 volts. The pure tungsten filament lamps have the longest average lifetime, and the thoria doped filament lamps have the shortest at 5.0 volts. The lifetimes of these lamps is about 7 years at an operating voltage of 3.5 volts. Data suggest that the rhenium doped lamps will have the longest average lifetime at 3.5 volts, and the thoria doped will have the shortest. These lifetimes are comparable to the desired lifetimes of 7 years.

  15. Atomic force microscopy analysis of human cornea surface after UV (λ=266 nm) laser irradiation

    NASA Astrophysics Data System (ADS)

    Spyratou, E.; Makropoulou, M.; Moutsouris, K.; Bacharis, C.; Serafetinides, A. A.

    2009-07-01

    Efficient cornea reshaping by laser irradiation for correcting refractive errors is still a major issue of interest and study. Although the excimer laser wavelength of 193 nm is generally recognized as successful in ablating corneal tissue for myopia correction, complications in excimer refractive surgery leads to alternative laser sources and methods for efficient cornea treatment. In this work, ablation experiments of human donor cornea flaps were conducted with the 4th harmonic of an Nd:YAG laser, with different laser pulses. AFM analysis was performed for examination of the ablated cornea flap morphology and surface roughness.

  16. Pulse Repetition Frequency Effects In A High Average Power X-Ray Preionised Excimer Laser

    NASA Astrophysics Data System (ADS)

    Fontaine, Bernard L.; Forestier, Bernard M.; Delaporte, Philippe C.; Canarelli, Patrick

    1989-10-01

    Experimental study of waves damping in a high repetition rate excimer laser is undertaken. Excitation of laser active medium in a subsonic loop is achieved by means of a classical discharge, through transfer capacitors. The discharge stability is controlled by a wire ion plasma (w.i.p.) X-rays gun. The strong acoustic waves induced by the active medium excitation may lead to a decrease, at high PRF, of the energy per pulse. First results of the influence of a damping of induced density perturbations between two successive pulses are presented.

  17. UV Raman scattering measurements in a Mach 2 H2-air flame for assessment of CFD models

    NASA Technical Reports Server (NTRS)

    Cheng, T. S.; Wehrmeyer, J. A.; Pitz, R. W.; Jarrett, O., Jr.; Northam, G. B.

    1991-01-01

    An UV narrowband tunable excimer laser is used for spontaneous Raman scattering measurements in hydrogen diffusion flames. The UV Raman system is characterized by a repetition rate of about 100 Hz, a temporal resolution of about 20 ns, and a spatial resolution of about 0.4 mm. It is concluded that a single KrF excimer laser based on spontaneous Raman scattering in conjunction with laser-induced predissociative fluorescence is capable of measuring instantaneously and simultaneously major species (H2, O2, N2, H2O), minor species (OH), and temperature.

  18. Xenon excimer emission from pulsed high-pressure capillary microdischarges

    NASA Astrophysics Data System (ADS)

    Lee, Byung-Joon; Rahaman, Hasibur; Petzenhauser, Isfried; Frank, Klaus; Giapis, Konstantinos P.

    2007-06-01

    Intense xenon vacuum ultraviolet (VUV) emission is observed from a high-pressure capillary cathode microdischarge in direct current operation, by superimposing a high-voltage pulse of 50ns duration. Under stagnant gas conditions, the total VUV light intensity increases linearly with pressure from 400 to 1013mbar for a fixed voltage pulse. At fixed pressure, however, the VUV light intensity increases superlinearly with voltage pulse height ranging from 08to2.8kV. Gains in emission intensity are obtained by inducing gas flow through the capillary cathode, presumably because of excimer dimer survival due to gas cooling.

  19. Critical review on refractive surgical lasers

    NASA Astrophysics Data System (ADS)

    Lin, J. T.

    1995-03-01

    The current status of refractive surgical lasers (including excimer and nonexcimer lasers) is reviewed with an emphasis on photorefractive keratectomy (PRK). The correlation of engineering parameters and the clinical requirements with optimal conditions are presented. The fundamentals of corneal reshaping with formulas for ablation profiles and the advantages of the multizone method are discussed. Updated information on the Mini-Excimer PRK laser system, with an emphasis on the scanning delivery device, is presented. PMMA ablation profiles performed by standard diaphragm and scanning modes are compared for surface ablation quality. Scanning mode ablation patterns for myopia, hyperopia, and regular and irregular astigmatism are presented.

  20. Spectrally narrowed lasing of a self-injection KrF excimer laser

    NASA Astrophysics Data System (ADS)

    Shimada, Yasuhiro; Wani, Koichi; Miki, Tadaaki; Kawahara, Hidehito; Mimasu, Mutsumi; Ogata, Yoshiro

    1990-08-01

    Spectrally nantwed lasing of a KrF excimer laser has teen ahieved by a self-injection technique using abeam splitter for power extraction aixi intravity etalons for spectral-narrowing. The laser cavity is divithi into an amplifying branch aix! a spectralnarrowing branch. The spectral bandwidth was narrowed to <3pm FWHM with air-sed etalons placed in the spectral-narrowing branch. A laser propagation model was intrOdUced for describing the laser intensity traveling in the laser cavity. The calculated intensityincident onthe intracavityetalons wassmaller thanthat in theconventional Fabry-Perotcavity withplane-parallel mirrors.

  1. 193nm high power lasers for the wide bandgap material processing

    NASA Astrophysics Data System (ADS)

    Fujimoto, Junichi; Kobayashi, Masakazu; Kakizaki, Koji; Oizumi, Hiroaki; Mimura, Toshio; Matsunaga, Takashi; Mizoguchi, Hakaru

    2017-02-01

    Recently infrared laser has faced resolution limit of finer micromachining requirement on especially semiconductor packaging like Fan-Out Wafer Level Package (FO-WLP) and Through Glass Via hole (TGV) which are hard to process with less defect. In this study, we investigated ablation rate with deep ultra violet excimer laser to explore its possibilities of micromachining on organic and glass interposers. These results were observed with a laser microscopy and Scanning Electron Microscope (SEM). As the ablation rates of both materials were quite affordable value, excimer laser is expected to be put in practical use for mass production.

  2. High resolution imaging studies into the formation of laser-induced periodic surface structures.

    PubMed

    Kerr, N C; Clark, S E; Emmony, D C

    1989-09-01

    We report the results of an investigation into the formation mechanism of laser-induced ripple structures based on obtaining direct images of a surface while the transient heating induced by a KrF excimer laser is still present. These images reveal transient but well-defined periodic heating patterns which, if enough subsequent excimer pulses are incident on the surface, become permanently induced ripple structures. It is evident from these transient images that the surface heating is confined to the induced structures, thus strongly supporting the idea that at low fluences the ripples are formed by localizing surface melting.

  3. A remote operating slit lamp microscope system. Development and its utility in ophthalmologic examinations.

    PubMed

    Tanabe, N; Go, K; Sakurada, Y; Imasawa, M; Mabuchi, F; Chiba, T; Abe, K; Kashiwagi, K

    2011-01-01

    To develop a remote-operating slit lamp microscope system (the remote slit lamp) as the core for highly specialized ophthalmology diagnoses, and to compare the utility of this system with the conventional slit lamp microscope system (the conventional slit lamp) in making a diagnosis. The remote slit lamp system was developed. Three factors were evaluated in comparison to the conventional slit lamp. The ability to acquire skills was investigated using a task loading system among specialists and residents in ophthalmology. Participants repeated a task up to ten times and the time required for each task was analyzed. The consistency of the two systems in making a diagnosis was investigated using eyes of patients with ocular diseases as well as healthy volunteers. The remote slit lamp is composed of a patient's unit and ophthalmologist's unit connected by high-speed internet. The two units share images acquired by the slit lamp in addition to the images and voices of patients and ophthalmologists. Both ophthalmology specialists and residents could minimize the completion times after several trials. The remote slit lamp took more time than the conventional slit lamp. Both systems showed a high consistency in evaluations among eyes with healthy eyes or those with ocular diseases. The remote slit lamp has a similar diagnostic ability, but required more examination time in comparison to the conventional slit lamp. The currently developed remote slit lamp has the potential to be employed for tele-medicine purposes in the field of ophthalmology.

  4. Multiple factors and processes involved in host cell killing by bacteriophage Mu: characterization and mapping.

    PubMed

    Waggoner, B T; Marrs, C F; Howe, M M; Pato, M L

    1984-07-15

    The regions of bacteriophage Mu involved in host cell killing were determined by infection of a lambda-immune host with 12 lambda pMu-transducing phages carrying different amounts of Mu DNA beginning at the left end. Infecting lambda pMu phages containing 5.0 (+/- 0.2) kb or less of the left end of Mu DNA did not kill the lambda-immune host, whereas lambda pMu containing 5.1 kb did kill, thus locating the right end of the kil gene between approximately 5.0 and 5.1 kb. For the Kil+ phages the extent of killing increased as the multiplicity of infection (m.o.i.) increased. In addition, killing was also affected by the presence of at least two other regions of Mu DNA: one, located between 5.1 and 5.8 kb, decreased the extent of killing; the other, located between 6.3 and 7.9 kb, greatly increased host cell killing. Killing was also assayed after lambda pMu infection of a lambda-immune host carrying a mini-Mu deleted for most of the B gene and the middle region of Mu DNA. Complementation of mini-Mu replication by infecting B+ lambda pMu phages resulted in killing of the lambda-immune, mini-Mu-containing host, regardless of the presence or absence of the Mu kil gene. The extent of host cell killing increased as the m.o.i. of the infecting lambda pMu increased, and was further enhanced by both the presence of the kil gene and the region located between 6.3 and 7.9 kb. These distinct processes of kil-mediated killing in the absence of replication and non-kil-mediated killing in the presence of replication were also observed after induction of replication-deficient and kil mutant prophages, respectively.

  5. Study of the strong {sigma}{sub c}{yields}{lambda}{sub c}{pi},{sigma}{sub c}*{yields}{lambda}{sub c}{pi} and {xi}{sub c}*{yields}{xi}{sub c}{pi} decays in a nonrelativistic quark model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Albertus, C.; Nieves, J.; Hernandez, E.

    We present results for the strong widths corresponding to the {sigma}{sub c}{yields}{lambda}{sub c}{pi}, {sigma}{sub c}*{yields}{lambda}{sub c}{pi} and {xi}{sub c}*{yields}{xi}{sub c}{pi} decays. The calculations have been done in a nonrelativistic constituent quark model with wave functions that take advantage of the constraints imposed by heavy quark symmetry. Partial conservation of axial current hypothesis allows us to determine the strong vertices from an analysis of the axial current matrix elements. Our results {gamma}({sigma}{sub c}{sup ++}{yields}{lambda}{sub c}{sup +}{pi}{sup +})=2.41{+-}0.07{+-}0.02 MeV, {gamma}({sigma}{sub c}{sup +}{yields}{lambda}{sub c}{sup +}{pi}{sup 0})=2.79{+-}0.08{+-}0.02 MeV, {gamma}({sigma}{sub c}{sup 0}{yields}{lambda}{sub c}{sup +}{pi}{sup -})=2.37{+-}0.07{+-}0.02 MeV, {gamma}({sigma}{sub c}*{sup ++}{yields}{lambda}{sub c}{sup +}{pi}{sup +})=17.52{+-}0.74{+-}0.12 MeV, {gamma}({sigma}{sub c}*{supmore » +}{yields}{lambda}{sub c}{sup +}{pi}{sup 0})=17.31{+-}0.73{+-}0.12 MeV, {gamma}({sigma}{sub c}*{sup 0}{yields}{lambda}{sub c}{sup +}{pi}{sup -})=16.90{+-}0.71{+-}0.12 MeV, {gamma}({xi}{sub c}*{sup +}{yields}{xi}{sub c}{sup 0}{pi}{sup +}+{xi}{sub c}{sup +}{pi}{sup 0})=3.18{+-}0.10{+-}0.01 MeV, and {gamma}({xi}{sub c}*{sup 0}{yields}{xi}{sub c}{sup +}{pi}{sup -}+{xi}{sub c}{sup 0}{pi}{sup 0})=3.03{+-}0.10{+-}0.01 MeV are in good agreement with experimental determinations.« less

  6. Excimer laser irradiation of metal surfaces

    NASA Astrophysics Data System (ADS)

    Kinsman, Grant

    In this work a new method of enhancing CO2 laser processing by modifying the radiative properties of a metal surface is studied. In this procedure, an excimer laser (XeCl) or KrF) exposes the metal surface to overlapping pulses of high intensity, 10(exp 8) - 10(exp 9) W cm(exp -2), and short pulse duration, 30 nsec FWHM (Full Width Half Maximum), to promote structural and chemical change. The major processing effect at these intensities is the production of a surface plasma which can lead to the formation of a laser supported detonation wave (LSD wave). This shock wave can interact with the thin molten layer on the metal surface influencing to a varying degree surface oxidation and roughness features. The possibility of the expulsion, oxidation and redeposition of molten droplets, leading to the formation of micron thick oxide layers, is related to bulk metal properties and the incident laser intensity. A correlation is found between the expulsion of molten droplets and a Reynolds number, showing the interaction is turbulent. The permanent effects of these interactions on metal surfaces are observed through scanning electron microscopy (SEM), transient calorimetric measurements and Fourier transform infrared (FTIR) spectroscopy. Observed surface textures are related to the scanning procedures used to irradiate the metal surface. Fundamental radiative properties of a metal surface, the total hemispherical emissivity, the near-normal spectral absorptivity, and others are examined in this study as they are affected by excimer laser radiation. It is determined that for heavily exposed Al surface, alpha' (10.6 microns) can be increased to values close to unity. Data relating to material removal rates and chemical surface modification for excimer laser radiation is also discussed. The resultant reduction in the near-normal reflectivity solves the fundamental problem of coupling laser radiation into highly reflective and conductive metals such as copper and aluminum. The increased absorption at 10.6 microns enables enhanced CO2 laser drilling and cutting rates in electrolytic Cu at incident intensities, I(0) of approximately 10(exp 6) W cm(exp -2). Data showing enhanced drilling rates in Al 1100-H14 is also presented. In these regimes the majority of material is removed in the liquid state. The amount of molten material formed can be directly attributed to the enhanced initial coupling of the excimer laser irradiated surface. Previously, to process Cu and Al it has been required to increase I(0) until material removal occurs through vaporization. This fundamental data and analysis provides a basic framework for further work in this new field of study.

  7. Modified van Vaals-Bergman coaxial cable coil (lambda coil) for high-field imaging.

    PubMed

    Matsuzawa, H; Nakada, T

    1996-03-01

    An easily constructed, low-capacitive coupling volume coil based on the van Vaals-Bergman coaxial cable coil for high field imaging is described. The coil (designated "lambda coil") was constructed using two 5/4 length 50 omega coaxial cables matched to a 50 omega transmission line with LC bridge balun. The standing wave on the single 5/4 lambda length coaxial cable provides two points of current maxima in oppositional direction. Therefore, the four current elements necessary for effective B1 field generation can be obtained by two 5/4 lambda length coaxial cables arranged analogous to 1/2 lambda T-antenna. Capacitive coupling between the coil elements and conductive samples (i.e. animals) is minimized by simply retaining the shield of the coaxial cable for the area of voltage maxima. The lambda coil exhibited excellent performance as a volume coil with a high quality factor and highly homogeneous rf fields. Because of its dramatically simple architecture and excellent performance, the lambda coil configuration appears to be an economical alternative to the original van Vaals-Bergman design, especially for research facilities with a high field magnet and limited bore space.

  8. Wind and boundary layers in Rayleigh-Bénard convection. II. Boundary layer character and scaling.

    PubMed

    van Reeuwijk, Maarten; Jonker, Harm J J; Hanjalić, Kemo

    2008-03-01

    The scaling of the kinematic boundary layer thickness lambda(u) and the friction factor C(f) at the top and bottom walls of Rayleigh-Bénard convection is studied by direct numerical simulation (DNS). By a detailed analysis of the friction factor, a new parameterisation for C(f) and lambda(u) is proposed. The simulations were made of an L/H=4 aspect-ratio domain with periodic lateral boundary conditions at Ra=(10(5), 10(6), 10(7), 10(8)) and Pr=1. The continuous spectrum, as well as significant forcing due to Reynolds stresses, clearly indicates a turbulent character of the boundary layer, while viscous effects cannot be neglected, judging from the scaling of classical integral boundary layer parameters with Reynolds number. Using a conceptual wind model, we find that the friction factor C(f) should scale proportionally to the thermal boundary layer thickness as C(f) proportional variant lambda(Theta)/H, while the kinetic boundary layer thickness lambda(u) scales inversely proportionally to the thermal boundary layer thickness and wind Reynolds number lambda(u)/H proportional variant (lambda(Theta)/H)(-1)Re(-1). The predicted trends for C(f) and lambda(u) are in agreement with DNS results.

  9. Neurotoxic effects of lambda-cyhalothrin modulated by piperonyl butoxide in the brain of Oreochromis niloticus.

    PubMed

    Piner, Petek; Üner, Nevin

    2014-11-01

    The objective of this research was to investigate the neurotoxic effects of pyrethroid pesticide lambda-cyhalothrin by the modulation of cytochrome P450 with piperonyl butoxide in the brain of juvenile Oreochromis niloticus. The fish were exposed to 0.48 μg L(-1) (1/6 of the 96-h LC50 ) lambda-cyhalothrin and 10 μg L(-1) piperonyl butoxide for 96 h and 15 days. tGSH, GSSG, TBARS contents, GPx, GR, GST, and AChE enzymes activities were determined by spectrophotometrical methods and Hsp70 content was analyzed by ELISA technique. Lambda-cyhalothrin had no significant effect on the components of GSH redox system, lipid peroxidation and Hsp70 levels but inhibited AChE activity. In the presence of piperonyl butoxide, lambda-cyhalothrin caused increases in tGSH, GSSG, TBARS and Hsp70 contents, GST activity, and decrease in AChE activity. Present results showed that in the presence of piperonyl butoxide, lambda-cyhalothrin caused neurotoxic effects by increasing oxidative stress. Adaptation to its oxidative stress effects may be supplied by GSH-related antioxidant system. Piperonyl butoxide revealed neurotoxic effect of lambda-cyhalothrin. Copyright © 2013 Wiley Periodicals, Inc., a Wiley company.

  10. Preliminary use of nematic liquid crystal adaptive optics with a 2.16-meter reflecting telescope.

    PubMed

    Cao, Zhaoliang; Mu, Quanquan; Hu, Lifa; Li, Dayu; Peng, Zenghui; Liu, Yonggang; Xuan, Li

    2009-02-16

    A nematic liquid crystal adaptive optics system (NLC AOS) was assembled for a 2.16-m telescope to correct for atmospheric turbulence. LC AOS was designed and optimized with Zemax optical software. Second, an adaptive correction experiment was performed in the laboratory to test the performance of the NLC AOS. After the correction, the peak to valley (PV) and root mean square (RMS) of the wavefront were down to 0.2 lambda (lambda=633 nm) and 0.05 lambda, respectively. Finally, the star of Pollux (beta Gem) was tracked using the 2.16-m Reflecting Telescope, and real time correction of the atmospheric turbulence was performed with the NLC AOS. After the adaptive correction, the average PV and RMS of the wavefront were reduced from 11 lambda and 2.5 lambda to 2.3 lambda and 0.6 lambda, respectively. Although the intensity distribution of the beta Gem was converged and its peak was sharp, a halo still existed around the peak. These results indicated that the NLC AOS only partially corrected the vertical atmospheric turbulence. The limitations of our NLC AOS are discussed and some proposals are made.

  11. Eternal triangle: the interaction of light source, electrical control gear, and optics

    NASA Astrophysics Data System (ADS)

    S'heeren, Griet

    1998-04-01

    In this particular 'affair' the participants are less than human but have individual personalities they bring to their relationship with each other. High pressure metal halide lamps such as BriteArc lamps have the highest luminance and radiance of all continuously operating practical light source. Since these lamps have short arcs and are available in power ratings from about 30W to 30kW they have found applications with various optical systems. Besides the lamps, such systems include an electrical control device and an optical system. To fulfil the user's requirements for a specific application, it is not only important to choose the right lamp, but crucial to achieve a harmonious marriage between the light source, electrical control device and the optics. To run a high pressure discharge lamp an ignitor/ballast system is essential This stabilizes the lamp parameters. The chemical components inside the lamp determine the lamp voltage and the gear determines, via the current, the lamp power. These are directly related in the luminance and color temperature of the emitted light. Therefore lamp performance and effective life are dependent on the ignitor, control gear and lamp combination. Since the lamp emits radiation in all directions, collection of the light from a lamp can be improved by using reflectors to deliver the light into a lens system. Since lamps with short arc gaps approach a point source they appear ideal for optical system applications. The shape of the reflector and the focusing of the lamp determine which part of the light is collected out of the light-arc. In the case of an LCD projector, the final light output also depends on the transmission characteristics of the LCD panels. Their nonlinearity causes the color of the emitted light to be different from the lamp color. All these parameters have to be optimized to obtain the highest performance. This leads to the conclusion that a carefully matched combination of lamp, ignitor/ballast and optics should guarantee the best system performance. This paper sets out to provide some guidelines on attempting to achieve a harmonious relationship between the three partners in this particular eternal triangle.

  12. The use of Loop-mediated Isothermal Amplification (LAMP) to detect the re-emerging Human African Trypanosomiasis (HAT) in the Luangwa and Zambezi valleys

    PubMed Central

    2012-01-01

    Background Loop-mediated isothermal amplification (LAMP) is a novel strategy which amplifies DNA with high sensitivity and rapidity under isothermal conditions. In the present study, the performance of the repetitive insertion mobile element (RIME)-LAMP and human serum resistance-associated gene (SRA)-LAMP assays were evaluated using clinical specimens obtained from four male patients from Luangwa and Zambezi valleys in Zambia and Zimbabwe, respectively. Findings The cases reported in this preliminary communication were all first diagnosed by microscopy, through passive surveillance, and confirmed by both RIME-LAMP and SRA-LAMP. A good correlation between microscopy and LAMP was observed and contributed to staging and successful treatment of patient. RIME-LAMP and SRA-LAMP complimented each other well in all the cases. Conclusions Both RIME-LAMP and SRA-LAMP were able to detect Trypanosoma brucei rhodesiense DNA in patient blood and CSF and hence confirmed HAT in the parasitaemic patients. Our study indicates that the LAMP technique is a potential tool for HAT diagnosis, staging and may be useful for making therapeutic decisions. However, no statistically significant conclusion may be drawn due to the limited sample size used in the present study. It is thus imperative to conduct a detailed study to further evaluate the potential of LAMP as a bedside diagnostic test for HAT. PMID:23211002

  13. 40 CFR 458.40 - Applicability; description of the carbon black lamp process subcategory.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... carbon black lamp process subcategory. 458.40 Section 458.40 Protection of Environment ENVIRONMENTAL... CATEGORY Carbon Black Lamp Process Subcategory § 458.40 Applicability; description of the carbon black lamp... production of carbon black by the lamp process. ...

  14. Effects of tag loss on direct estimates of population growth rate

    USGS Publications Warehouse

    Rotella, J.J.; Hines, J.E.

    2005-01-01

    The temporal symmetry approach of R. Pradel can be used with capture-recapture data to produce retrospective estimates of a population's growth rate, lambda(i), and the relative contributions to lambda(i) from different components of the population. Direct estimation of lambda(i) provides an alternative to using population projection matrices to estimate asymptotic lambda and is seeing increased use. However, the robustness of direct estimates of lambda(1) to violations of several key assumptions has not yet been investigated. Here, we consider tag loss as a possible source of bias for scenarios in which the rate of tag loss is (1) the same for all marked animals in the population and (2) a function of tag age. We computed analytic approximations of the expected values for each of the parameter estimators involved in direct estimation and used those values to calculate bias and precision for each parameter estimator. Estimates of lambda(i) were robust to homogeneous rates of tag loss. When tag loss rates varied by tag age, bias occurred for some of the sampling situations evaluated, especially those with low capture probability, a high rate of tag loss, or both. For situations with low rates of tag loss and high capture probability, bias was low and often negligible. Estimates of contributions of demographic components to lambda(i) were not robust to tag loss. Tag loss reduced the precision of all estimates because tag loss results in fewer marked animals remaining available for estimation. Clearly tag loss should be prevented if possible, and should be considered in analyses of lambda(i), but tag loss does not necessarily preclude unbiased estimation of lambda(i).

  15. Cholinergic dysfunctions and enhanced oxidative stress in the neurobehavioral toxicity of lambda-cyhalothrin in developing rats.

    PubMed

    Ansari, Reyaz W; Shukla, Rajendra K; Yadav, Rajesh S; Seth, Kavita; Pant, Aditya B; Singh, Dhirendra; Agrawal, Ashok K; Islam, Fakhrul; Khanna, Vinay K

    2012-11-01

    This study is focused on understanding the mechanism of neurobehavioral toxicity of lambda-cyhalothrin, a new generation type II synthetic pyrethroid in developing rats following their exposure from post-lactational day (PLD)22 to PLD49 and investigate whether neurobehavioral alterations are transient or persistent. Post-lactational exposure to lambda-cyhalothrin (1.0 or 3.0 mg/kg body weight, p.o.) affected grip strength and learning activity in rats on PLD50 and the persistent impairment of grip strength and learning was observed at 15 days after withdrawal of exposure on PLD65. A decrease in the binding of muscarinic-cholinergic receptors in frontocortical, hippocampal, and cerebellar membranes associated with decreased expression of choline acetyltransferase (ChAT) and acetylcholinesterase (AChE) in hippocampus was observed following exposure to lambda-cyhalothrin on PLD50 and PLD65. Exposure to lambda-cyhalothrin was also found to increase the expression of growth-associated protein-43 in hippocampus of rats on PLD50 and PLD65 as compared to controls. A significant increase in lipid peroxidation and protein carbonyl levels and decreased levels of reduced glutathione and activity of superoxide dismutase, catalase, and glutathione peroxidase in brain regions of lambda-cyhalothrin exposed rats were distinctly observed indicating increased oxidative stress. Inhibition of ChAT and AChE activity may cause down-regulation of muscarinic-cholinergic receptors consequently impairing learning activity in developing rats exposed to lambda-cyhalothrin. The data further indicate that long-term exposure to lambda-cyhalothrin at low doses may be detrimental and changes in selected behavioral and neurochemical end points may persist if exposure to lambda-cyhalothrin continues.

  16. Environmental impacts of lighting technologies - Life cycle assessment and sensitivity analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Welz, Tobias; Hischier, Roland, E-mail: Roland.Hischier@empa.ch; Hilty, Lorenz M.

    2011-04-15

    With two regulations, 244/2009 and 245/2009, the European Commission recently put into practice the EuP Directive in the area of lighting devices, aiming to improve energy efficiency in the domestic lighting sector. This article presents a comprehensive life cycle assessment comparison of four different lighting technologies: the tungsten lamp, the halogen lamp, the conventional fluorescent lamp and the compact fluorescent lamp. Taking advantage of the most up-to-date life cycle inventory database available (ecoinvent data version 2.01), all life cycle phases were assessed and the sensitivity of the results for varying assumptions analysed: different qualities of compact fluorescent lamps (production phase),more » different electricity mixes (use phase), and end-of-life scenarios for WEEE recycling versus municipal solid waste incineration (disposal phase). A functional unit of 'one hour of lighting' was defined and the environmental burdens for the whole life cycle for all four lamp types were calculated, showing a clearly lower impact for the two gas-discharge lamps, i.e. the fluorescent and the compact fluorescent lamp. Differences in the product quality of the compact fluorescent lamps reveal to have only a very small effect on the overall environmental performance of this lamp type; a decline of the actual life time of this lamp type doesn't result in a change of the rank order of the results of the here examined four lamp types. It was also shown that the environmental break-even point of the gas-discharge lamps is reached long before the end of their expected life-span. All in all, it can be concluded that a change from today's tungsten lamp technology to a low-energy-consuming technology such as the compact fluorescent lamp results in a substantial environmental benefit.« less

  17. Studies on Temperature Dependence of Rubidium Lamp for Atomic Frequency Standard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghosal, Bikash; Banik, Alak; Vats, Vaibhav

    2011-10-20

    Rb lamp is a very critical component of the Rb atomic clock's Physics Package. The Rb lamp's performance is very sensitive to temperature and its stability. In this paper we discuss the behaviors of Rb Lamp with temperature. The Rb lamp exciter power and temperature of Rb bulb are very important parameters in controlling the performance of the Rb Lamp. It is observed that at temperatures beyond 110 deg. C, the lamp mode changes from the ring to red mode resulting in abnormal broadening of emission lines and self reversal. The results of our studies on spectral analysis of Rbmore » lamp under various operating conditions are reported in the paper.« less

  18. Bacteriophage lambda: early pioneer and still relevant

    PubMed Central

    Casjens, Sherwood R.; Hendrix, Roger W.

    2015-01-01

    Molecular genetic research on bacteriophage lambda carried out during its golden age from the mid 1950's to mid 1980's was critically important in the attainment of our current understanding of the sophisticated and complex mechanisms by which the expression of genes is controlled, of DNA virus assembly and of the molecular nature of lysogeny. The development of molecular cloning techniques, ironically instigated largely by phage lambda researchers, allowed many phage workers to switch their efforts to other biological systems. Nonetheless, since that time the ongoing study of lambda and its relatives have continued to give important new insights. In this review we give some relevant early history and describe recent developments in understanding the molecular biology of lambda's life cycle. PMID:25742714

  19. The Protein Interaction Network of Bacteriophage Lambda with Its Host, Escherichia coli

    PubMed Central

    Blasche, Sonja; Wuchty, Stefan; Rajagopala, Seesandra V.

    2013-01-01

    Although most of the 73 open reading frames (ORFs) in bacteriophage λ have been investigated intensively, the function of many genes in host-phage interactions remains poorly understood. Using yeast two-hybrid screens of all lambda ORFs for interactions with its host Escherichia coli, we determined a raw data set of 631 host-phage interactions resulting in a set of 62 high-confidence interactions after multiple rounds of retesting. These links suggest novel regulatory interactions between the E. coli transcriptional network and lambda proteins. Targeted host proteins and genes required for lambda infection are enriched among highly connected proteins, suggesting that bacteriophages resemble interaction patterns of human viruses. Lambda tail proteins interact with both bacterial fimbrial proteins and E. coli proteins homologous to other phage proteins. Lambda appears to dramatically differ from other phages, such as T7, because of its unusually large number of modified and processed proteins, which reduces the number of host-virus interactions detectable by yeast two-hybrid screens. PMID:24049175

  20. Simultaneous display of two large proteins on the head and tail of bacteriophage lambda

    PubMed Central

    2013-01-01

    Background Consistent progress in the development of bacteriophage lambda display platform as an alternative to filamentous phage display system was achieved in the recent years. The lambda phage has been engineered to display efficiently multiple copies of peptides or even large protein domains providing a powerful tool for screening libraries of peptides, proteins and cDNA. Results In the present work we describe an original method for dual display of large proteins on the surface of lambda particles. An anti-CEA single-chain antibody fragment and green fluorescent protein or alkaline phosphatase were simultaneously displayed by engineering both gpD and gpV lambda proteins. Conclusions Here we show that such modified phage particles can be used for the detection of target molecules in vitro and in vivo. Dual expression of functional moieties on the surface of the lambda phage might open the way to generation of a new class of diagnostic and therapeutic targeted nanoparticles. PMID:24073829

  1. Selection of Optical Glasses Using Buchdahl's Chromatic Coordinate

    NASA Technical Reports Server (NTRS)

    Griffin, DeVon W.

    1999-01-01

    This investigation attempted to extend the method of reducing the size of glass catalogs to a global glass selection technique with the hope of guiding glass catalog offerings. Buchdahl's development of optical aberration coefficients included a transformation of the variable in the dispersion equation from wavelength to a chromatic coordinate omega defined as omega = (lambda - lambda(sub 0))/ 1 + 2.5(lambda - lambda(sub 0)) where lambda is the wavelength at which the wavelength is calculated and lambda(sub 0) is a base wavelength about which the expansion is performed. The advantage of this approach is that the dispersion equation may be written in terms of a simple power series and permits direct calculation of dispersion coefficients. While several promising examples were given, a systematic application of the technique to an entire glass catalog and analysis of the subsequent predictions was not performed. The goal of this work was to apply the technique in a systematic fashion to glasses in the Schoft catalog and assess the quality of the predictions.

  2. Exposure and health assessment during application of lambda-cyhalothrin for malaria vector control in Pakistan.

    PubMed

    Chester, G; Sabapathy, N N; Woollen, B H

    1992-01-01

    Icon 10 WP insecticide, a wettable powder formulation containing 10% lambda-cyhalothrin, was evaluated for possible adverse effects on the health of spraymen and villagers during treatment of dwellings for malaria vector control. Skin sensory effects and occasional coughing and sneezing in confined spaces were the only symptoms noted by the workers resulting from the handling and spraying of the insecticide. Absorption of lambda-cyhalothrin was estimated by determining its metabolites in urine and serum. The average amount of lambda-cyhalothrin absorbed by the workers per day (54 micrograms) represents less than 0.0001% (< 1 micrograms.kg-1.day-1) of the average daily amount of the substance handled. Only a small proportion of villagers showed detectable levels of lambda-cyhalothrin metabolites in their urine. Absorption of lambda-cyhalothrin from the formulation tested was therefore very low and, apart from the nuisance of skin sensory effects, there should be no risk to the health of workers or to the villagers whose dwellings are treated.

  3. Exposure and health assessment during application of lambda-cyhalothrin for malaria vector control in Pakistan.

    PubMed Central

    Chester, G.; Sabapathy, N. N.; Woollen, B. H.

    1992-01-01

    Icon 10 WP insecticide, a wettable powder formulation containing 10% lambda-cyhalothrin, was evaluated for possible adverse effects on the health of spraymen and villagers during treatment of dwellings for malaria vector control. Skin sensory effects and occasional coughing and sneezing in confined spaces were the only symptoms noted by the workers resulting from the handling and spraying of the insecticide. Absorption of lambda-cyhalothrin was estimated by determining its metabolites in urine and serum. The average amount of lambda-cyhalothrin absorbed by the workers per day (54 micrograms) represents less than 0.0001% (< 1 micrograms.kg-1.day-1) of the average daily amount of the substance handled. Only a small proportion of villagers showed detectable levels of lambda-cyhalothrin metabolites in their urine. Absorption of lambda-cyhalothrin from the formulation tested was therefore very low and, apart from the nuisance of skin sensory effects, there should be no risk to the health of workers or to the villagers whose dwellings are treated. PMID:1464147

  4. Two-dimensional energy spectra in high-Reynolds-number turbulent boundary layers

    NASA Astrophysics Data System (ADS)

    Chandran, Dileep; Baidya, Rio; Monty, Jason P.; Marusic, Ivan

    2017-09-01

    Here we report the measurements of two-dimensional (2-D) spectra of the streamwise velocity ($u$) in a high Reynolds number turbulent boundary layer. A novel experiment employing multiple hot-wire probes was carried out at friction Reynolds numbers ranging from 2400 to 26000. Taylor's frozen turbulence hypothesis is used to convert temporal-spanwise information into a 2-D spatial spectrum which shows the contribution of streamwise ($\\lambda_x$) and spanwise ($\\lambda_y$) length scales to the streamwise variance at a given wall height ($z$). At low Reynolds numbers, the shape of the 2-D spectra at a constant energy level shows $\\lambda_y/z \\sim (\\lambda_x/z)^{1/2}$ behaviour at larger scales, which is in agreement with the existing literature at a matched Reynolds number obtained from direct numerical simulations. However, at high Reynolds numbers, it is observed that the square-root relationship tends towards a linear relationship ($\\lambda_y \\sim \\lambda_x$) as required for self-similarity and predicted by the attached eddy hypothesis.

  5. Physical parameters of lambda Bootis stars

    NASA Astrophysics Data System (ADS)

    Solano, E.; Paunzen, E.; Pintado, O. I.; Córdoba; Varela, J.

    2001-08-01

    This is the first of two papers whose main goal is to update and improve the information available on the physical properties of the lambda Bootis stars. The determination of the stellar parameters is of fundamental importance to shed light into the different theories proposed to explain the lambda Bootis phenomenon. With this aim, projected rotational velocities, effective temperatures, surface gravities and chemical abundances of a sample of suspected lambda Bootis stars have been calculated. Five objects showing composite spectra typical of binary systems were found in our analysis. The abundance distribution of the program stars does not resemble the chemical composition of the class prototype, lambda Boo, which poses some concerns regarding the idea of a well-defined, chemically homogeneous group of stars. A possible relation between rotational velocities and the lambda Bootis phenomenon has been found. This result would be in agreement with the accretion scenario proposed by Turcotte & Charbonneau (\\cite{Turcotte93}). Figure 3 is only available in electronic form at http://www.edpsciences.org

  6. Effects of Spinosad, Imidacloprid, and Lambda-cyhalothrin on Survival, Parasitism, and Reproduction of the Aphid Parasitoid Aphidius colemani.

    PubMed

    D'Ávila, Vinicius A; Barbosa, Wagner F; Guedes, Raul N C; Cutler, G Christopher

    2018-05-28

    Insecticides can affect biological control by parasitoids. Here, we examined the lethal and sublethal effects of two conventional insecticides, imidacloprid and lambda-cyhalothrin, and a reduced-risk bioinsecticide, spinosad, on the aphid parasitoid Aphidius colemani Viereck (Hymenoptera: Braconidae). Concentration-mortality curves generated from insecticide residue bioassays found that wasps were nearly 20-fold more susceptible to spinosad than imidacloprid and lambda-cyhalothrin. Imidacloprid and lambda-cyhalothrin compromised adult parasitoid longevity, but not as dramatically as spinosad: concentrations >200 ng spinosad/cm2 reduced wasp longevity by half. Imidacloprid and lambda-cyhalothrin also compromised aphid parasitism by wasps. Although increasing imidacloprid concentrations led to increased host viability and reduced progeny production, lambda-cyhalothrin did not affect viability of parasitized hosts or parasitoid progeny production in a dose-dependent manner. Our results demonstrate that reduced risk bioinsecticide products like spinosad can be more toxic to biological control agents than certain conventional insecticides.

  7. 49 CFR 234.221 - Lamp voltage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Lamp voltage. 234.221 Section 234.221..., Inspection, and Testing Maintenance Standards § 234.221 Lamp voltage. The voltage at each lamp shall be maintained at not less than 85 percent of the prescribed rating for the lamp. ...

  8. 49 CFR 234.221 - Lamp voltage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Lamp voltage. 234.221 Section 234.221..., Inspection, and Testing Maintenance Standards § 234.221 Lamp voltage. The voltage at each lamp shall be maintained at not less than 85 percent of the prescribed rating for the lamp. ...

  9. Peginterferon Lambda-1a Is Associated with a Low Incidence of Autoimmune Thyroid Disease in Chronic Hepatitis C.

    PubMed

    Fredlund, Paul; Hillson, Jan; Gray, Todd; Shemanski, Lynn; Dimitrova, Dessislava; Srinivasan, Subasree

    2015-11-01

    Peginterferon alfa (alfa) increases the risk of autoimmune disease. Peginterferon lambda-1a (Lambda) acts through a receptor with a more liver-specific distribution compared to the alfa receptor. In a phase-2b study, 525 treatment-naive patients with chronic hepatitis C virus (HCV) infection received ribavirin and Lambda interferon (120, 180, or 240 μg) or alfa interferon (180 μg) for 24 (genotypes 2 and 3) or 48 (genotypes 1 and 4) weeks. Retrospective analysis found that adverse events of MedDRA-coded thyroid dysfunction and abnormal levels of thyroid-stimulating hormone (TSH) were significantly more frequent with alfa versus Lambda (12% versus 2.6% and 15.2% versus 3.4%, respectively, both P<0.0001). Most Lambda recipients with abnormal TSH had levels below the lower limit of normal; the frequency of low and high TSH was similar in alfa recipients with abnormal TSH. Blinded review by an endocrinologist found that new-onset primary hypothyroidism or painless thyroiditis was less frequent with Lambda versus alfa (0.5% and 1.8% versus 5.3% and 7.5%, respectively, P<0.0001). Most TSH elevations reflected new-onset hypothyroidism requiring treatment, while most markedly suppressed TSH values reflected probable painless thyroiditis and resolved without sequelae. In conclusion, HCV-infected patients treated with Lambda/ribavirin experienced fewer adverse events of thyroid dysfunction compared with patients treated with alfa/ribavirin.

  10. Neutral-strange-particle production in 200-GeV/ c p /. pi. sup + / K sup + interactions on Au, Ag, and Mg

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brick, D.H.; Widgoff, M.; Beilliere, P.

    1992-02-01

    We have used the Fermilab 30-in. bubble-chamber--hybrid spectrometer to study neutral-strange-particle production in the interactions of 200-GeV/{ital c} protons and {pi}{sup +} and {ital K}{sup +} mesons with nuclei of gold, silver, and magnesium. Average multiplicities and inclusive cross sections for {ital K}{sup 0} and {Lambda} are measured, and a power law is found to give a good description of their {ital A} dependence. The exponent characterizing the {ital A} dependence is consistent with being the same for {ital K}{sup 0} and {Lambda} production, and also the same for proton and {pi}{sup +} beams. Average {ital K}{sup 0} and {Lambda}more » multiplicities, as well as their ratio, have been measured as functions of the numbers of projectile collisions {nu}{sub {ital p}} and secondary collisions {nu}{sub {ital s}} in the nucleus, and indicate that rescattering contributes significantly to enhancement of {Lambda} production but not to {ital K}{sup 0} production. The properties of events with multiple {ital K}{sup 0}'s or {Lambda}'s also corroborate this conclusion. {ital K}{sup 0} rapidities are in the central region and decrease gently with increasing {nu}{sub {ital p}}, while {Lambda} rapidities are in the target-fragmentation region and are independent of {nu}{sub {ital p}}. {ital K}{sup 0} and {Lambda} multiplicities increase with the rapidity loss of the projectile, but their rapidities do not.« less

  11. THERMALLY DRIVEN ATMOSPHERIC ESCAPE: TRANSITION FROM HYDRODYNAMIC TO JEANS ESCAPE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Volkov, Alexey N.; Johnson, Robert E.; Tucker, Orenthal J.

    2011-03-10

    Thermally driven escape from planetary atmospheres changes in nature from an organized outflow (hydrodynamic escape) to escape on a molecule-by-molecule basis (Jeans escape) with increasing Jeans parameter, {lambda}, the ratio of the gravitational to thermal energy of the atmospheric molecules. This change is described here for the first time using the direct simulation Monte Carlo method. When heating is predominantly below the lower boundary of the simulation region, R{sub 0}, and well below the exobase of a single-component atmosphere, the nature of the escape process changes over a surprisingly narrow range of Jeans parameters, {lambda}{sub 0}, evaluated at R{sub 0}.more » For an atomic gas, the transition occurs over {lambda}{sub 0} {approx} 2-3, where the lower bound, {lambda}{sub 0} {approx} 2.1, corresponds to the upper limit for isentropic, supersonic outflow. For {lambda}{sub 0} > 3 escape occurs on a molecule-by-molecule basis and we show that, contrary to earlier suggestions, for {lambda}{sub 0} > {approx}6 the escape rate does not deviate significantly from the familiar Jeans rate. In a gas composed of diatomic molecules, the transition shifts to {lambda}{sub 0} {approx} 2.4-3.6 and at {lambda}{sub 0} > {approx}4 the escape rate increases a few tens of percent over that for the monatomic gas. Scaling by the Jeans parameter and the Knudsen number, these results can be applied to thermally induced escape of the major species from solar and extrasolar planets.« less

  12. Laser-assisted in situ keratomileusis with optimized, fast-repetition, and cyclotorsion control excimer laser to treat hyperopic astigmatism with high cylinder.

    PubMed

    Alió Del Barrio, Jorge L; Tiveron, Mauro; Plaza-Puche, Ana B; Amesty, María A; Casanova, Laura; García, María J; Alió, Jorge L

    2017-10-18

    To evaluate the visual outcomes after femtosecond laser-assisted laser in situ keratomileusis (LASIK) surgery to correct primary compound hyperopic astigmatism with high cylinder using a fast repetition rate excimer laser platform with optimized aspheric profiles and cyclotorsion control. Eyes with primary simple or compound hyperopic astigmatism and a cylinder power ≥3.00 D had uneventful femtosecond laser-assisted LASIK with a fast repetition rate excimer laser ablation, aspheric profiles, and cyclotorsion control. Visual, refractive, and aberrometric results were evaluated at the 3- and 6-month follow-up. The astigmatic outcome was evaluated using the Alpins method and ASSORT software. This study enrolled 80 eyes at 3 months and 50 eyes at 6 months. The significant reduction in refractive sphere and cylinder 3 and 6 months postoperatively (p<0.01) was associated with an improved uncorrected distance visual acuity (p<0.01). A total of 23.75% required retreatment 3 months after surgery. Efficacy and safety indices at 6 months were 0.90 and 1.00, respectively. At 6 months, 80% of eyes had an SE within ±0.50 D and 96% within ±1.00 D. No significant differences were detected between the third and the sixth postoperative months in refractive parameters. A significant increase in the spherical aberration was detected, but not in coma. The correction index was 0.94 at 3 months. Laser in situ keratomileusis for primary compound hyperopic astigmatism with high cylinder (>3.00 D) using the latest excimer platforms with cyclotorsion control, fast repetition rate, and optimized aspheric profiles is safe, moderately effective, and predictable.

  13. XeCl excimer laser with new prism resonator configurations and its performance characteristics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benerji, N. S., E-mail: nsb@rrcat.gov.in, E-mail: bsingh@rrcat.gov.in; Singh, A.; Varshnay, N.

    2015-07-15

    New resonator cavity configurations, namely, the prism resonator and unstable prism resonator, are demonstrated for the first time in an excimer (XeCl) laser with interesting and novel results. High misalignment tolerance ∼50 mrad is achieved with considerably reduced beam divergence of less than ∼1 mrad without reduction in output power capabilities of the laser. The misalignment tolerance of ∼50 mrad is a dramatic improvement of ∼25 times compared to ∼2 mrad normally observed in standard excimer laser with plane-plane cavity. Increase in depth of focus from 3 mm to 5.5 mm was also achieved in case of prism resonator configurationmore » with an improvement of about 60%. Unstable prism resonator configuration is demonstrated here in this paper with further reduction in beam divergence to about 0.5 mrad using plano-convex lens as output coupler. The misalignment tolerance in case of unstable prism resonator was retained at about 30 mrad which is a high value compared to standard unstable resonators. The output beam spot was completely filled with flat-top profile with prism resonator configurations, which is desired for various material processing applications. Focusing properties and beam divergence in case of prism resonator have been investigated using SEM (scanning electron microscope) images. SEM images of the focused spot size (∼20 μm holes) on metal sheet indicate beam divergence of about 0.05 mrad which is about 1.5 times diffraction limit. Energy contained in this angle is thus sufficient for micro-machining applications. Clean and sharp edges of the micro-holes show high pointing stability with multiple shot exposures. Such characteristics of the excimer laser system will be extremely useful in micro-machining and other field applications.« less

  14. XeCl excimer laser with new prism resonator configurations and its performance characteristics.

    PubMed

    Benerji, N S; Singh, A; Varshnay, N; Singh, Bijendra

    2015-07-01

    New resonator cavity configurations, namely, the prism resonator and unstable prism resonator, are demonstrated for the first time in an excimer (XeCl) laser with interesting and novel results. High misalignment tolerance ∼50 mrad is achieved with considerably reduced beam divergence of less than ∼1 mrad without reduction in output power capabilities of the laser. The misalignment tolerance of ∼50 mrad is a dramatic improvement of ∼25 times compared to ∼2 mrad normally observed in standard excimer laser with plane-plane cavity. Increase in depth of focus from 3 mm to 5.5 mm was also achieved in case of prism resonator configuration with an improvement of about 60%. Unstable prism resonator configuration is demonstrated here in this paper with further reduction in beam divergence to about 0.5 mrad using plano-convex lens as output coupler. The misalignment tolerance in case of unstable prism resonator was retained at about 30 mrad which is a high value compared to standard unstable resonators. The output beam spot was completely filled with flat-top profile with prism resonator configurations, which is desired for various material processing applications. Focusing properties and beam divergence in case of prism resonator have been investigated using SEM (scanning electron microscope) images. SEM images of the focused spot size (∼20 μm holes) on metal sheet indicate beam divergence of about 0.05 mrad which is about 1.5 times diffraction limit. Energy contained in this angle is thus sufficient for micro-machining applications. Clean and sharp edges of the micro-holes show high pointing stability with multiple shot exposures. Such characteristics of the excimer laser system will be extremely useful in micro-machining and other field applications.

  15. Evaluation of the performance of small diode pumped UV solid state (DPSS) Nd:YAG lasers as new radiation sources for atmospheric pressure laser ionization mass spectrometry (APLI-MS).

    PubMed

    Kersten, Hendrik; Lorenz, Matthias; Brockmann, Klaus J; Benter, Thorsten

    2011-06-01

    The performance of a KrF* bench top excimer laser and a compact diode pumped UV solid state (DPSS) Nd:YAG laser as photo-ionizing source in LC-APLI MS is compared. The commonly applied bench-top excimer laser, operating at 248 nm, provides power densities of the order of low MW/cm(2) on an illuminated area of 0.5 cm(2) (8 mJ/pulse, 5 ns pulse duration, beam waist area 0.5 cm(2), 3 MW/cm(2)). The DPSS laser, operating at 266 nm, provides higher power densities, however, on a two orders of magnitude smaller illuminated area (60 μJ/pulse, 1 ns pulse duration, beam waist area 2 × 10(-3) cm(2), 30 MW/cm(2)). In a common LC-APLI MS setup with direct infusion of a 10 nM pyrene solution, the DPSS laser yields a significantly smaller ion signal (0.9%) and signal to noise ratio (1.4%) compared with the excimer laser. With respect to the determined low detection limits (LODs) for PAHs of 0.1 fmol using an excimer laser, LODs in DPSS laser LC-APLI MS in the low pmol regime are expected. The advantages of the DPSS laser with respect to applicability (size, cost, simplicity) may render this light source the preferred one for APLI applications not focusing on ultimately high sensitivities. Furthermore, the impact of adjustable ion source parameters on the performance of both laser systems is discussed in terms of the spatial sensitivity distribution described by the distribution of ion acceptance (DIA) measurements. Perspectives concerning the impact on future APLI-MS applications are given.

  16. Composition of the excimer laser-induced plume produced during LASIK refractive surgery

    NASA Astrophysics Data System (ADS)

    Glickman, Randolph D.; Liu, Yun; Mayo, George L.; Baribeau, Alan D.; Starck, Tomy; Bankhead, Tom

    2003-07-01

    Because of concerns about potential hazards to surgical personnel of the plume associated with laser refractive surgery, this study was performed to characterize the composition of such plumes. Filter elements were removed from the smoke evacuator of a VISX S3 excimer laser (filter pore size ~0.3 microns) and from a Mastel Clean Room ( filter pore size ~0.2 microns) used with a LADARVISION excimer laser. The filters from both laser systems captured the laser-induced plumes from multiple, routine, LASIK patient procedures. Some filters were processed for scanning electron microscopy, while others were extracted with methanol and chloroform for biochemical analysis. Both the VISX "Final Air" filter and the Mastel "Clean Room" filter captured material that was not observed in filters that had clean operating room air only passed through them. In the VISX system, air flows through the filter unit parallel to the filter matrix. SEM analysis showed these filters captured discrete particles of 0.3 to 3.0 microns in size. In the Mastel Clean Room unit, air flows orthogonally through the filter, and the filter matrix was heavily layered with captured debris so that individual particles were not readily distinguished. Amino acid analysis and gel electrophoresis of extracted material revealed proteinaceous molecules as large as 5000 molecular weight. Such large molecules in the laser plume are not predicted by the existing theory of photochemical ablation. The presence of relatively large biomolecules may constitute a risk of allergenic reactions in personnel exposed to the plume, and also calls into question the precise mechanism of excimer laser photochemical ablation. Supported by the RMG Research Endowment, and Research to Prevent Blindness

  17. A retrospective comparison of efficacy and safety of 680 consecutive lasik treatments for high myopia performed with two generations of flying-spot excimer lasers.

    PubMed

    Gazieva, Lola; Beer, Mette Hjuler; Nielsen, Kim; Hjortdal, Jesper

    2011-12-01

    To compare the visual refractive outcome and complication of laser in situ keratomileusis (LASIK) carried out with a Carl Zeiss-Meditec MEL-70 Excimer laser and a MEL-80 laser for treatment of high myopia. Journal records of 680 consecutive eyes that underwent LASIK with a Schwind Supratome microkeratome and a MEL-70 Excimer laser (Group A), or a Moria M2 microkeratome and a MEL-80 Excimer laser (Group B) were reviewed. Manifest refraction, uncorrected and best spectacle-corrected visual acuity (BSCVA), corneal topography and central corneal thickness (CCT) were recorded before and 3 months after treatment. Pre- and postoperative complications, visual and refractive outcome and frequency of retreatments were registered. Mean preoperative spherical equivalent refraction was -8.52 dioptres (-5.50- -18 dioptres), and the mean attempted laser correction was -8.02 dioptres (-5.50- -11 dioptres). Three months after LASIK, the average treatment error (difference between achieved and attempted correction) was 1.20 (SD=1.19) dioptres of under correction in Group A and 0.52 (SD=1.00) dioptres in Group B. Four eyes lost more than two lines of BSCVA (0.6%). In 110 eyes (16%), a re-LASIK procedure was performed to reduce remaining myopia after the primary procedure. Laser in situ keratomileusis treatment for high myopia can effectively reduce high degrees of myopia. Under correction was observed in both treatment groups but Group B has a slightly better predictability. Significant loss of BSCVA occurs infrequently after LASIK for even considerable grades of myopia (0.6% in each group). © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.

  18. Active Knowledge Structures for Natural Language Processing.

    DTIC Science & Technology

    1991-01-01

    specialist belief: Assume there is a lambda-expression "(LAMBDA L) immed-type-ofL" and Z = ((LAMBDA L) immed-type-of L) ( thalassemia ), we can describe...SPEC) -> ([AVG-PERSON] -> (VAL-FOR) -> CGREEK-PLCE)3 This expresses the various levels of specialized knowledge of thalassemia , depending on

  19. Physics of Incandescent Lamp Burnout

    ERIC Educational Resources Information Center

    Gluck, Paul; King, John

    2008-01-01

    Incandescent lamps with tungsten filaments have been in use for about a century while being gradually replaced by fluorescent lamps; in another generation both will quite probably be largely replaced by light-emitting diodes. Incandescent lamps (simply called "lamps" in what follows) burn out after a lifetime that depends mostly on the temperature…

  20. 40 CFR 273.5 - Applicability-lamps.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 28 2013-07-01 2013-07-01 false Applicability-lamps. 273.5 Section 273...) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT General § 273.5 Applicability—lamps. (a) Lamps covered under this part 273. The requirements of this part apply to persons managing lamps as described in § 273.9, except...

  1. 30 CFR 75.522-1 - Incandescent and fluorescent lamps.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Incandescent and fluorescent lamps. 75.522-1...-1 Incandescent and fluorescent lamps. (a) Except for areas of a coal mine inby the last open crosscut, incandescent lamps may be used to illuminate underground areas. When incandescent lamps are used...

  2. 40 CFR 273.5 - Applicability-lamps.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Applicability-lamps. 273.5 Section 273...) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT General § 273.5 Applicability—lamps. (a) Lamps covered under this part 273. The requirements of this part apply to persons managing lamps as described in § 273.9, except...

  3. 49 CFR 393.9 - Lamps operable, prohibition of obstructions of lamps and reflectors.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 5 2013-10-01 2013-10-01 false Lamps operable, prohibition of obstructions of lamps and reflectors. 393.9 Section 393.9 Transportation Other Regulations Relating to Transportation... SAFETY REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and...

  4. 47 CFR 17.54 - Rated lamp voltage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Rated lamp voltage. 17.54 Section 17.54... STRUCTURES Specifications for Obstruction Marking and Lighting of Antenna Structures § 17.54 Rated lamp... lamps used shall correspond to be within 3 percent higher than the voltage across the lamp socket during...

  5. 49 CFR 393.9 - Lamps operable, prohibition of obstructions of lamps and reflectors.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Lamps operable, prohibition of obstructions of lamps and reflectors. 393.9 Section 393.9 Transportation Other Regulations Relating to Transportation... SAFETY REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and...

  6. 49 CFR 393.9 - Lamps operable, prohibition of obstructions of lamps and reflectors.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 5 2014-10-01 2014-10-01 false Lamps operable, prohibition of obstructions of lamps and reflectors. 393.9 Section 393.9 Transportation Other Regulations Relating to Transportation... SAFETY REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and...

  7. 30 CFR 75.522-1 - Incandescent and fluorescent lamps.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Incandescent and fluorescent lamps. 75.522-1...-1 Incandescent and fluorescent lamps. (a) Except for areas of a coal mine inby the last open crosscut, incandescent lamps may be used to illuminate underground areas. When incandescent lamps are used...

  8. 47 CFR 17.54 - Rated lamp voltage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Rated lamp voltage. 17.54 Section 17.54... STRUCTURES Specifications for Obstruction Marking and Lighting of Antenna Structures § 17.54 Rated lamp... lamps used shall correspond to be within 3 percent higher than the voltage across the lamp socket during...

  9. 30 CFR 75.522-1 - Incandescent and fluorescent lamps.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Incandescent and fluorescent lamps. 75.522-1...-1 Incandescent and fluorescent lamps. (a) Except for areas of a coal mine inby the last open crosscut, incandescent lamps may be used to illuminate underground areas. When incandescent lamps are used...

  10. 30 CFR 75.522-1 - Incandescent and fluorescent lamps.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Incandescent and fluorescent lamps. 75.522-1...-1 Incandescent and fluorescent lamps. (a) Except for areas of a coal mine inby the last open crosscut, incandescent lamps may be used to illuminate underground areas. When incandescent lamps are used...

  11. 40 CFR 273.5 - Applicability-lamps.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Applicability-lamps. 273.5 Section 273...) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT General § 273.5 Applicability—lamps. (a) Lamps covered under this part 273. The requirements of this part apply to persons managing lamps as described in § 273.9, except...

  12. 47 CFR 17.54 - Rated lamp voltage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Rated lamp voltage. 17.54 Section 17.54... STRUCTURES Specifications for Obstruction Marking and Lighting of Antenna Structures § 17.54 Rated lamp... lamps used shall correspond to be within 3 percent higher than the voltage across the lamp socket during...

  13. 47 CFR 17.54 - Rated lamp voltage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Rated lamp voltage. 17.54 Section 17.54... STRUCTURES Specifications for Obstruction Marking and Lighting of Antenna Structures § 17.54 Rated lamp... lamps used shall correspond to be within 3 percent higher than the voltage across the lamp socket during...

  14. 30 CFR 75.522-1 - Incandescent and fluorescent lamps.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Incandescent and fluorescent lamps. 75.522-1...-1 Incandescent and fluorescent lamps. (a) Except for areas of a coal mine inby the last open crosscut, incandescent lamps may be used to illuminate underground areas. When incandescent lamps are used...

  15. 40 CFR 273.5 - Applicability-lamps.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 28 2012-07-01 2012-07-01 false Applicability-lamps. 273.5 Section 273...) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT General § 273.5 Applicability—lamps. (a) Lamps covered under this part 273. The requirements of this part apply to persons managing lamps as described in § 273.9, except...

  16. 47 CFR 17.54 - Rated lamp voltage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Rated lamp voltage. 17.54 Section 17.54... STRUCTURES Specifications for Obstruction Marking and Lighting of Antenna Structures § 17.54 Rated lamp... lamps used shall correspond to be within 3 percent higher than the voltage across the lamp socket during...

  17. 49 CFR 393.9 - Lamps operable, prohibition of obstructions of lamps and reflectors.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 5 2012-10-01 2012-10-01 false Lamps operable, prohibition of obstructions of lamps and reflectors. 393.9 Section 393.9 Transportation Other Regulations Relating to Transportation... SAFETY REGULATIONS PARTS AND ACCESSORIES NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and...

  18. 40 CFR 273.5 - Applicability-lamps.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Applicability-lamps. 273.5 Section 273...) STANDARDS FOR UNIVERSAL WASTE MANAGEMENT General § 273.5 Applicability—lamps. (a) Lamps covered under this part 273. The requirements of this part apply to persons managing lamps as described in § 273.9, except...

  19. Driving lamps by induction

    NASA Technical Reports Server (NTRS)

    Laue, H. H.; Clough, L. G. (Inventor)

    1973-01-01

    An electrodeless lamp circuit with a coil surrounding a krypton lamp is driven by an RF input source. A coil surrounding a mercury lamp is tapped across the connection of the input central to the krypton-lamp coil. Each coil is connected in parallel with separate capacitors which form resonant circuits at the input frequency.

  20. Development of a loop-mediated isothermal amplification (LAMP) assay for rapid and specific detection of common genetically modified organisms (GMOs).

    PubMed

    Feng, Jiawang; Tang, Shiming; Liu, Lideng; Kuang, Xiaoshan; Wang, Xiaoyu; Hu, Songnan; You, Shuzhu

    2015-03-01

    Here, we developed a loop-mediated isothermal amplification (LAMP) assay for 11 common transgenic target DNA in GMOs. Six sets of LAMP primer candidates for each target were designed and their specificity, sensitivity, and reproductivity were evaluated. With the optimized LAMP primers, this LAMP assay was simply run within 45-60 min to detect all these targets in GMOs tested. The sensitivity, specificity, and reproductivity of the LAMP assay were further analyzed in comparison with those of Real-Time PCR. In consistent with real-time PCR, detection of 0.5% GMOs in equivalent background DNA was possible using this LAMP assay for all targets. In comparison with real-time PCR, the LAMP assay showed the same results with simple instruments. Hence, the LAMP assay developed can provide a rapid and simple approach for routine screening as well as specific events detection of many GMOs.

  1. Life cycle analysis of greenhouse gas emissions for fluorescent lamps in mainland China.

    PubMed

    Chen, Sha; Zhang, Jiaxing; Kim, Junbeum

    2017-01-01

    China is the world's largest emitter of carbon dioxide, and it is also one of the largest fluorescent lamp consuming and producing country in the world. However, there are few studies evaluating greenhouse gas (GHG) emissions of fluorescent lamps in China. This analysis compared GHG emissions of compact fluorescent lamps with linear fluorescent lamps using life cycle assessment method in China's national conditions. The GHG emissions of fluorescent lamps from their manufacture to the final disposal phase on the national level of China were also quantified. The results indicate that the use phase dominates the GHG emissions for both lamps. Linear fluorescent lamp is a better source of light compared to compact fluorescent lamp with respect to GHG emissions. The analysis found that in 2011, China generated around 710.90milliontons CO 2 -eq associated with fluorescent lamps. The raw material production and use phases accounted for major GHG emissions. More than half of GHG emissions during the domestic production were embodied in the exported lamps in recent years. This urges the government to take necessary measures that lead to more environmental friendly production, consumption and trade patterns. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. T(sub lambda) Depression by a Heat Current Along the lambda-Line

    NASA Technical Reports Server (NTRS)

    Liu, Yuanming; Larson, Melora; Iraelsson, Ulf E.

    1999-01-01

    We report measurements of the depression of the superfluid transition temperature by a heat current (1 less than or = Q less than or = 100 microW/sq cm) along the lambda-line (SVP less than or = P less than or = 21.6 bar). At P = 21.6 bar, measurements were also performed in a reduced gravity (0.2g). Experimental results show that the pressure dependence of the depression and the gravity effect on the measurements are small, in qualitative agreement with theoretical predictions. Keywords: superfluid helium; Lambda transition; heat current

  3. Biomechanical stability analysis of the lambda-model controlling one joint.

    PubMed

    Lan, L; Zhu, K Y

    2007-06-01

    Computer modeling and control of the human motor system might be helpful for understanding the mechanism of human motor system and for the diagnosis and treatment of neuromuscular disorders. In this paper, a brief view of the equilibrium point hypothesis for human motor system modeling is given, and the lambda-model derived from this hypothesis is studied. The stability of the lambda-model based on equilibrium and Jacobian matrix is investigated. The results obtained in this paper suggest that the lambda-model is stable and has a unique equilibrium point under certain conditions.

  4. Phase correlation of laser waves with arbitrary frequency spacing.

    PubMed

    Huss, A F; Lammegger, R; Neureiter, C; Korsunsky, E A; Windholz, L

    2004-11-26

    The theoretically predicted correlation of laser phase fluctuations in Lambda-type interaction schemes is experimentally demonstrated. We show that the mechanism of correlation in a Lambda scheme is restricted to high-frequency noise components, whereas in a double-Lambda scheme, due to the laser phase locking in a closed-loop interaction, it extends to all noise frequencies. In this case the correlation is weakly sensitive to coherence losses. Thus the double-Lambda scheme can be used to correlate electromagnetic fields with carrier frequency differences beyond the GHz regime.

  5. [Extraction of lambda-cyhalothrin from aqueous dioxan solutions].

    PubMed

    Shormanov, V K; Chigareva, E N; Belousova, O V

    2011-01-01

    The results of extraction of lambda-cigalotrin from dioxan aqueous solutions by hydrophobic organic solvents are presented. It is shown that the degree of extraction depends on the nature of the extractant, the water to dioxan ratio, and saturation of the water-dioxan layer with the electrolyte. The highest efficiency of lambda-cigalotrin extraction was achieved using chlorophorm as a solvent under desalination conditions. The extraction factor was calculated necessary to obtain the desired amount of lambda-cigalotrin from the water-dioxan solution (4:1) with the help of the extractants being used.

  6. Far-infrared spectrophotometer for astronomical observations

    NASA Technical Reports Server (NTRS)

    Moseley, H.; Silverberg, R. F.

    1981-01-01

    A liquid-helium-cooled far infrared spectrophotometer was built and used to make low resolution observations of the continua of several kinds of astronomical objects using the Kuiper Airborne Observatory. This instrument fills a gap in both sensitivity to continuum sources and spectral resolution between the broadband photometers with lambda/Delta lambda approximately 1 and spectrometers with lambda/Delta lambda greater than 50. While designed primarily to study planetary nebulae, the instrument permits study of the shape of the continua of many weak sources which cannot easily be observed with high resolution systems.

  7. [Spectral emissivity of thin films].

    PubMed

    Zhong, D

    2001-02-01

    In this paper, the contribution of multiple reflections in thin film to the spectral emissivity of thin films of low absorption is discussed. The expression of emissivity of thin films derived here is related to the thin film thickness d and the optical constants n(lambda) and k(lambda). It is shown that in the special case d-->infinity the emissivity of thin films is equivalent to that of the bulk material. Realistic numerical and more precise general numerical results for the dependence of the emissivity on d, n(lambda) and k(lambda) are given.

  8. Short-Term Exposure to Lambda-Cyhalothrin Negatively Affects the Survival and Memory-Related Characteristics of Worker Bees Apis mellifera.

    PubMed

    Liao, Chun-Hua; He, Xu-Jiang; Wang, Zi-Long; Barron, Andrew B; Zhang, Bo; Zeng, Zhi-Jiang; Wu, Xiao-Bo

    2018-07-01

    Pesticides are considered one of the major contemporary stressors of honey bee health. In this study, the effects of short-term exposure to lambda-cyhalothrin on lifespan, learning, and memory-related characteristics of Apis mellifera were systematically examined. Short-term exposure to lambda-cyhalothrin in worker bees reduced lifespan, affected learning and memory performance, reduced the homing ability, and influenced the expression levels of two learning and memory-related genes of A. mellifera. This research identifies the nature of the sublethal effects of lambda-cyhalothrin on bees and the level of exposure that can be harmful to bee health. This new information will assist in establishing guidelines for the safe use of lambda-cyhalothrin in the field.

  9. Quantitation of IgG kappa and IgG lambda in the cerebrospinal fluid by sandwich ELISA method.

    PubMed

    Zeman, David; Kušnierová, Pavlína; Bojková, Jana; Všianský, František; Zapletalová, Olga

    2017-01-01

    IgG kappa and IgG lambda concentrations were quantified in 96 paired CSF and sera using Hevylite™ antibodies in an in-house developed sandwich ELISA method. In 56 of these samples, the results were compared with a qualitative isoelectric focusing/affinity-mediated immunoblotting assay for oligoclonal IgG kappa and IgG lambda. Normal IgG kappa/lambda ratio in the CSF was the same as in serum. In 19/33 patients with intrathecal oligoclonal IgG synthesis, skewed IgG kappa/lambda ratio was observed (increased in 16 and decreased in 3 cases). The analysis of light chain composition of intrathecally synthesised immunoglobulins could contribute to our understanding of intrathecal humoral immune response, although its diagnostic utility is limited.

  10. Particle-type dependence of azimuthal anisotropy and nuclear modification of particle production in Au+Au collisions at square root of sNN=200 GeV.

    PubMed

    Adams, J; Adler, C; Aggarwal, M M; Ahammed, Z; Amonett, J; Anderson, B D; Anderson, M; Arkhipkin, D; Averichev, G S; Badyal, S K; Balewski, J; Barannikova, O; Barnby, L S; Baudot, J; Bekele, S; Belaga, V V; Bellwied, R; Berger, J; Bezverkhny, B I; Bhardwaj, S; Bhaskar, P; Bhati, A K; Bichsel, H; Billmeier, A; Bland, L C; Blyth, C O; Bonner, B E; Botje, M; Boucham, A; Brandin, A; Bravar, A; Cadman, R V; Cai, X Z; Caines, H; Calderón de la Barca Sánchez, M; Carroll, J; Castillo, J; Castro, M; Cebra, D; Chaloupka, P; Chattopadhyay, S; Chen, H F; Chen, Y; Chernenko, S P; Cherney, M; Chikanian, A; Choi, B; Christie, W; Coffin, J P; Cormier, T M; Cramer, J G; Crawford, H J; Das, D; Das, S; Derevschikov, A A; Didenko, L; Dietel, T; Dong, W J; Dong, X; Draper, J E; Du, F; Dubey, A K; Dunin, V B; Dunlop, J C; Dutta Majumdar, M R; Eckardt, V; Efimov, L G; Emelianov, V; Engelage, J; Eppley, G; Erazmus, B; Estienne, M; Fachini, P; Faine, V; Faivre, J; Fatemi, R; Filimonov, K; Filip, P; Finch, E; Fisyak, Y; Flierl, D; Foley, K J; Fu, J; Gagliardi, C A; Gagunashvili, N; Gans, J; Ganti, M S; Gaudichet, L; Germain, M; Geurts, F; Ghazikhanian, V; Ghosh, P; Gonzalez, J E; Grachov, O; Grigoriev, V; Gronstal, S; Grosnick, D; Guedon, M; Guertin, S M; Gupta, A; Gushin, E; Gutierrez, T D; Hallman, T J; Hardtke, D; Harris, J W; Heinz, M; Henry, T W; Heppelmann, S; Herston, T; Hippolyte, B; Hirsch, A; Hjort, E; Hoffmann, G W; Horsley, M; Huang, H Z; Huang, S L; Humanic, T J; Igo, G; Ishihara, A; Jacobs, P; Jacobs, W W; Janik, M; Jiang, H; Johnson, I; Jones, P G; Judd, E G; Kabana, S; Kaneta, M; Kaplan, M; Keane, D; Khodyrev, V Yu; Kiryluk, J; Kisiel, A; Klay, J; Klein, S R; Klyachko, A; Koetke, D D; Kollegger, T; Kopytine, M; Kotchenda, L; Kovalenko, A D; Kramer, M; Kravtsov, P; Kravtsov, V I; Krueger, K; Kuhn, C; Kulikov, A I; Kumar, A; Kunde, G J; Kunz, C L; Kutuev, R Kh; Kuznetsov, A A; Lamont, M A C; Landgraf, J M; Lange, S; Lansdell, C P; Lasiuk, B; Laue, F; Lauret, J; Lebedev, A; Lednický, R; LeVine, M J; Li, C; Li, Q; Lindenbaum, S J; Lisa, M A; Liu, F; Liu, L; Liu, Z; Liu, Q J; Ljubicic, T; Llope, W J; Long, H; Longacre, R S; Lopez-Noriega, M; Love, W A; Ludlam, T; Lynn, D; Ma, J; Ma, Y G; Magestro, D; Mahajan, S; Mangotra, L K; Mahapatra, D P; Majka, R; Manweiler, R; Margetis, S; Markert, C; Martin, L; Marx, J; Matis, H S; Matulenko, Yu A; McShane, T S; Meissner, F; Melnick, Yu; Meschanin, A; Messer, M; Miller, M L; Milosevich, Z; Minaev, N G; Mironov, C; Mishra, D; Mitchell, J; Mohanty, B; Molnar, L; Moore, C F; Mora-Corral, M J; Morozov, D A; Morozov, V; de Moura, M M; Munhoz, M G; Nandi, B K; Nayak, S K; Nayak, T K; Nelson, J M; Nevski, P; Nikitin, V A; Nogach, L V; Norman, B; Nurushev, S B; Odyniec, G; Ogawa, A; Okorokov, V; Oldenburg, M; Olson, D; Paic, G; Pandey, S U; Pal, S K; Panebratsev, Y; Panitkin, S Y; Pavlinov, A I; Pawlak, T; Perevoztchikov, V; Perkins, C; Peryt, W; Petrov, V A; Phatak, S C; Picha, R; Planinic, M; Pluta, J; Porile, N; Porter, J; Poskanzer, A M; Potekhin, M; Potrebenikova, E; Potukuchi, B V K S; Prindle, D; Pruneau, C; Putschke, J; Rai, G; Rakness, G; Raniwala, R; Raniwala, S; Ravel, O; Ray, R L; Razin, S V; Reichhold, D; Reid, J G; Renault, G; Retiere, F; Ridiger, A; Ritter, H G; Roberts, J B; Rogachevski, O V; Romero, J L; Rose, A; Roy, C; Ruan, L J; Sahoo, R; Sakrejda, I; Salur, S; Sandweiss, J; Savin, I; Schambach, J; Scharenberg, R P; Schmitz, N; Schroeder, L S; Schweda, K; Seger, J; Seliverstov, D; Seyboth, P; Shahaliev, E; Shao, M; Sharma, M; Shestermanov, K E; Shimanskii, S S; Singaraju, R N; Simon, F; Skoro, G; Smirnov, N; Snellings, R; Sood, G; Sorensen, P; Sowinski, J; Spinka, H M; Srivastava, B; Stanislaus, S; Stock, R; Stolpovsky, A; Strikhanov, M; Stringfellow, B; Struck, C; Suaide, A A P; Sugarbaker, E; Suire, C; Sumbera, M; Surrow, B; Symons, T J M; de Toledo, A Szanto; Szarwas, P; Tai, A; Takahashi, J; Tang, A H; Thein, D; Thomas, J H; Tikhomirov, V; Tokarev, M; Tonjes, M B; Trainor, T A; Trentalange, S; Tribble, R E; Trivedi, M D; Trofimov, V; Tsai, O; Ullrich, T; Underwood, D G; Van Buren, G; VanderMolen, A M; Vasiliev, A N; Vasiliev, M; Vigdor, S E; Viyogi, Y P; Voloshin, S A; Waggoner, W; Wang, F; Wang, G; Wang, X L; Wang, Z M; Ward, H; Watson, J W; Wells, R; Westfall, G D; Whitten, C; Wieman, H; Willson, R; Wissink, S W; Witt, R; Wood, J; Wu, J; Xu, N; Xu, Z; Xu, Z Z; Yamamoto, E; Yepes, P; Yurevich, V I; Zanevski, Y V; Zborovský, I; Zhang, H; Zhang, W M; Zhang, Z P; Zołnierczuk, P A; Zoulkarneev, R; Zoulkarneeva, J; Zubarev, A N

    2004-02-06

    We present STAR measurements of the azimuthal anisotropy parameter v(2) and the binary-collision scaled centrality ratio R(CP) for kaons and lambdas (Lambda+Lambda) at midrapidity in Au+Au collisions at square root of s(NN)=200 GeV. In combination, the v(2) and R(CP) particle-type dependencies contradict expectations from partonic energy loss followed by standard fragmentation in vacuum. We establish p(T) approximately 5 GeV/c as the value where the centrality dependent baryon enhancement ends. The K(0)(S) and Lambda+Lambda v(2) values are consistent with expectations of constituent-quark-number scaling from models of hadron formation by parton coalescence or recombination.

  11. Diffractive centrosymmetric 3D-transmission phase gratings positioned at the image plane of optical systems transform lightlike 4D-WORLD as tunable resonators into spectral metrics...

    NASA Astrophysics Data System (ADS)

    Lauinger, Norbert

    1999-08-01

    Diffractive 3D phase gratings of spherical scatterers dense in hexagonal packing geometry represent adaptively tunable 4D-spatiotemporal filters with trichromatic resonance in visible spectrum. They are described in the (lambda) - chromatic and the reciprocal (nu) -aspects by reciprocal geometric translations of the lightlike Pythagoras theorem, and by the direction cosine for double cones. The most elementary resonance condition in the lightlike Pythagoras theorem is given by the transformation of the grating constants gx, gy, gz of the hexagonal 3D grating to (lambda) h1h2h3 equals (lambda) 111 with cos (alpha) equals 0.5. Through normalization of the chromaticity in the von Laue-interferences to (lambda) 111, the (nu) (lambda) equals (lambda) h1h2h3/(lambda) 111-factor of phase velocity becomes the crucial resonance factor, the 'regulating device' of the spatiotemporal interaction between 3D grating and light, space and time. In the reciprocal space equal/unequal weights and times in spectral metrics result at positions of interference maxima defined by hyperbolas and circles. A database becomes built up by optical interference for trichromatic image preprocessing, motion detection in vector space, multiple range data analysis, patchwide multiple correlations in the spatial frequency spectrum, etc.

  12. Ion Viscosity Mediated by Tangled Magnetic Fields: An Application to Black Hole Accretion Disks

    NASA Technical Reports Server (NTRS)

    Subramanian, Prasad; Becker, Peter A.; Kafatos, Menas

    1996-01-01

    We examine the viscosity associated with the shear stress exerted by ions in the presence of a tangled magnetic field. As an application, we consider the effect of this mechanism on the structure of black hole accretion disks. We do not attempt to include a self-consistent description of the magnetic field. Instead, we assume the existence of a tangled field with coherence length lambda(sub coh), which is the average distance between the magnetic 'kinks' that scatter the particles. For simplicity, we assume that the field is self-similar, and take lambda(sub coh) to be a fixed fraction zeta of the local disk height H. Ion viscosity in the presence of magnetic fields is generally taken to be the cross-field viscosity, wherein the effective mean free path is the ion Larmor radius lambda(sub L), which is much less than the ion-ion Coulomb mean free path A(sub ii) in hot accretion disks. However, we arrive at a formulation for a 'hybrid' viscosity in which the tangled magnetic field acts as an intermediary in the transfer of momentum between different layers in the shear flow. The hybrid viscosity greatly exceeds the standard cross-field viscosity when (lambda/lambda(sub L)) much greater than (lambda(sub L)/lambda(sub ii)), where lambda = ((lambda(sub ii)(sup -1) + lambda(sub (coh)(sup -1))(sup -1) is the effective mean free path for the ions. This inequality is well satisfied in hot accretion disks, which suggests that the ions may play a much larger role in the momentum transfer process in the presence of magnetic fields than was previously thought. The effect of the hybrid viscosity on the structure of a steady-state, two-temperature, quasi-Keplerian accretion disk is analyzed. The hybrid viscosity is influenced by the degree to which the magnetic field is tangled (represented by zeta = lambda(sub coh)), and also by the relative accretion rate M/M(sub E), where M(sub E) = L(sub E)/c(sup 2) and L(sub E) is the Eddington luminosity. We find that ion viscosity in the presence of magnetic fields (hybrid viscosity) can dominate over conventional magnetic viscosity for fields that are tangled on sufficiently small scales.

  13. Color Degradation of Textiles with Natural Dyes and of Blue Scale Standards Exposed to White LED Lamps:Evaluation of White LED Lamps for Effectiveness as Museum Lighting

    NASA Astrophysics Data System (ADS)

    Ishii, Mie; Moriyama, Takayoshi; Toda, Masahiro; Kohmoto, Kohtaro; Saito, Masako

    White light-emitting diodes (LED) are well suited for museum lighting because they emit neither UV nor IR radiation, which damage artifacts. The color degradation of natural dyes and blue scale standards (JIS L 0841) by white LED lamps are examined, and the performance of white LED lamps for museum lighting is evaluated. Blue scale standard grades 1-6 and silk fabrics dyed with 22 types of natural dyes classified as mid to highly responsive in a CIE technical report (CIE157:2004) were exposed to five types of white LED lamps using different luminescence methods and color temperatures. Color changes were measured at each 15000 lx·hr (500 lx at fabric surface × 300 hr) interval ten times. The accumulated exposure totaled 150000 lx·hr. The data on conventional white LED lamps and previously reported white fluorescent (W) and museum fluorescent (NU) lamps was evaluated. All the white LED lamps showed lower fading rates compared with a W lamp on a blue scale grade 1. The fading rate of natural dyes in total was the same between an NU lamp (3000 K) and a white LED lamp (2869 K). However, yellow natural dyes showed higher fading rates with the white LED lamp. This tendency is due to the high power characteristic of the LED lamp around 400-500 nm, which possibly contributes to the photo-fading action on the dyes. The most faded yellow dyes were Ukon (Curcuma longa L.) and Kihada (Phellodendron amurense Rupr.), and these are frequently used in historic artifacts such as kimono, wood-block prints, and scrolls. From a conservation point of view, we need to continue research on white LED lamps for use in museum lighting.

  14. Dimming of metal halide lamps

    NASA Astrophysics Data System (ADS)

    Schurer, Kees

    1994-03-01

    We ran some tests on the effect of dimming of metal halide (MH) lamps upon the stability and the spectral quality of the light output. Lamps used were a new Philips lamp HPI-T 250W, a similar Philips lamp with a few thousand burning hours and a new Osram lamp HQI-T 250W/D. The ballast was a BBC type DJ 250/2KS, the starter a BAS TORGI type MZN 250 SE and the dimmer an Elstrom Control System type ERHQ-T 250. Power was derived from a Philips stabilizer, type PE 1602. Lamp output was monitored with a PAR meter. Spectra were taken at 100% and at 50% output as measured with the PAR meter. Lamps were allowed to stabilize at any setting for 30 minutes before measurements were made. Lamp manufacturers advise against dimming for fear of poor stability and intolerable changes of the spectrum. However, none of the lamps showed a decrease in stability, no flicker or wandering of the discharge, and the changes of the spectrum were not negligible, but certainly not dramatic. Lamps of either manufacture retain their white color, relative peak heights of spectral lines did shift, but no gaps in the spectrum occurred. Spectra taken at 50% with 30 minutes intervals coincided. Differences between the new and the older Philips lamp were noticeable, but not really significant.

  15. Dimming of metal halide lamps

    NASA Technical Reports Server (NTRS)

    Schurer, Kees

    1994-01-01

    We ran some tests on the effect of dimming of metal halide (MH) lamps upon the stability and the spectral quality of the light output. Lamps used were a new Philips lamp HPI-T 250W, a similar Philips lamp with a few thousand burning hours and a new Osram lamp HQI-T 250W/D. The ballast was a BBC type DJ 250/2KS, the starter a BAS TORGI type MZN 250 SE and the dimmer an Elstrom Control System type ERHQ-T 250. Power was derived from a Philips stabilizer, type PE 1602. Lamp output was monitored with a PAR meter. Spectra were taken at 100% and at 50% output as measured with the PAR meter. Lamps were allowed to stabilize at any setting for 30 minutes before measurements were made. Lamp manufacturers advise against dimming for fear of poor stability and intolerable changes of the spectrum. However, none of the lamps showed a decrease in stability, no flicker or wandering of the discharge, and the changes of the spectrum were not negligible, but certainly not dramatic. Lamps of either manufacture retain their white color, relative peak heights of spectral lines did shift, but no gaps in the spectrum occurred. Spectra taken at 50% with 30 minutes intervals coincided. Differences between the new and the older Philips lamp were noticeable, but not really significant.

  16. Recent Advances in Lighting Science

    NASA Astrophysics Data System (ADS)

    Lapatovich, Walter P.

    2004-10-01

    Lighting is a global industry supplying a wide array of devices and systems that emit light ranging from incandescent lamps to light emitting diodes to electric discharge lamps. Electric discharge lamps are the most familiar plasma devices to most people. This work focuses on plasma light sources, some advances in this area and recent trends. Plasma light sources fall into two broad categories, namely low pressure and high pressure. The low-pressure lamps operate in the range of 40 to 500 Pa while the high-pressure lamps operate in the range of 0.1 to 15 MPa. The corresponding electron temperatures are about 1eV and 0.5 eV for the low and high-pressure lamps respectively. High-pressure lamps are treated under the assumption of local thermodynamic equilibrium wherein the gas temperature is equilibrated with the electron temperature. They are often called high intensity discharge lamps because of their intrinsically high radiance. Within these two broad categories are many subgroups, perhaps the most important being mercury and non-mercury containing lamps. An example of a low pressure, mercury-containing lamp is the ubiquitous fluorescent lamp. Attempts to improve the efficiency of these lamps center around inductive excitation techniques and two-photon phosphor development. The plasma research on mercury-free low-pressure lamps is focused on finding substitutes for a mercury-rare gas discharge. Several ultraviolet emitting candidates have been explored which emit both UV and visible. Longer wavelength UV is of interest because of the parallel development of phosphors mated with LED excitation wavelengths around 380nm. Several examples will be discussed. There have been major advances in high intensity discharge lamps with and without mercury. Mercury containing metal halide lamps are now being fabricated from translucent ceramic envelopes instead of the conventional vitreous silica. The higher temperature tolerant envelope materials permit using discharges in vapors hitherto unacceptable because of chemical reactions. Temperature driven chemical reactions (which affect lamp life, starting and stability) are better understood. Lamps are better designed with finite element thermal modeling and thermodynamic computational tools. Improved understanding of molecular processes in the energy transport within the plasma has opened possibilities for new types of light sources relying heavily on molecular emission. Examples of lamps containing sulfur, indium, thallium and rare earth halides will be discussed. General trends in plasma based light source have been towards lower wattage, directed visible output, high quality visible output, longer life and mercury-free lamps. Consumer demand for high tech, high performance lighting devices has broadened the use of HID lamps in automobiles, video/data display and medical/technical applications. Short arc gap lamps (1mm) with a luminance exceeding that of the sun's surface (1600cd/mm2 -as observed from earth), and operating with extreme line broadening lead the video projection market. Low wattage HID lamps coupled with tailored optics can direct the light output more precisely leading to reduced light pollution and better system throughput. Tailoring of the driving electrical waveforms have enabled stable operation, controlled the effects of species segregation and improved lamp life and performance.

  17. 30 CFR 20.10 - Tests (class 1 and 2 lamps).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Tests (class 1 and 2 lamps). 20.10 Section 20... 1 and 2 lamps). Such tests will be made as are necessary to prove the adequacy of a lamp or any of... (storage-battery lamps of class 1). (e) Temperature tests. ...

  18. 30 CFR 20.9 - Class 2 lamps.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Class 2 lamps. 20.9 Section 20.9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC MINE LAMPS OTHER THAN STANDARD CAP LAMPS § 20.9 Class 2 lamps. (a) Safety. (1...

  19. 46 CFR 167.40-25 - Signaling lamp.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Signaling lamp. 167.40-25 Section 167.40-25 Shipping... Certain Equipment Requirements § 167.40-25 Signaling lamp. Nautical school ships of over 150 gross tons shall be equipped with an efficient signaling lamp. This lamp shall be permanently fixed above the...

  20. 30 CFR 75.1703-1 - Permissible lamps.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Permissible lamps. 75.1703-1 Section 75.1703-1... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703-1 Permissible lamps. Lamps... this chapter (Bureau of Mines Schedule 6D and Schedule 10C) are approved lamps for the purposes of § 75...

  1. 49 CFR 392.33 - Obscured lamps or reflective devices/material.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 5 2013-10-01 2013-10-01 false Obscured lamps or reflective devices/material. 392... REGULATIONS DRIVING OF COMMERCIAL MOTOR VEHICLES Use of Lighted Lamps and Reflectors § 392.33 Obscured lamps or reflective devices/material. (a) No commercial motor vehicle shall be driven when any of the lamps...

  2. 49 CFR 392.33 - Obscured lamps or reflective devices/material.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 5 2012-10-01 2012-10-01 false Obscured lamps or reflective devices/material. 392... REGULATIONS DRIVING OF COMMERCIAL MOTOR VEHICLES Use of Lighted Lamps and Reflectors § 392.33 Obscured lamps or reflective devices/material. (a) No commercial motor vehicle shall be driven when any of the lamps...

  3. 46 CFR 167.40-25 - Signaling lamp.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Signaling lamp. 167.40-25 Section 167.40-25 Shipping... Certain Equipment Requirements § 167.40-25 Signaling lamp. Nautical school ships of over 150 gross tons shall be equipped with an efficient signaling lamp. This lamp shall be permanently fixed above the...

  4. 30 CFR 75.1703-1 - Permissible lamps.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Permissible lamps. 75.1703-1 Section 75.1703-1... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703-1 Permissible lamps. Lamps... this chapter (Bureau of Mines Schedule 6D and Schedule 10C) are approved lamps for the purposes of § 75...

  5. 46 CFR 167.40-25 - Signaling lamp.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Signaling lamp. 167.40-25 Section 167.40-25 Shipping... Certain Equipment Requirements § 167.40-25 Signaling lamp. Nautical school ships of over 150 gross tons shall be equipped with an efficient signaling lamp. This lamp shall be permanently fixed above the...

  6. 30 CFR 75.1703-1 - Permissible lamps.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Permissible lamps. 75.1703-1 Section 75.1703-1... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703-1 Permissible lamps. Lamps... this chapter (Bureau of Mines Schedule 6D and Schedule 10C) are approved lamps for the purposes of § 75...

  7. 30 CFR 75.1703-1 - Permissible lamps.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Permissible lamps. 75.1703-1 Section 75.1703-1... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703-1 Permissible lamps. Lamps... this chapter (Bureau of Mines Schedule 6D and Schedule 10C) are approved lamps for the purposes of § 75...

  8. 30 CFR 75.1703-1 - Permissible lamps.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Permissible lamps. 75.1703-1 Section 75.1703-1... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703-1 Permissible lamps. Lamps... this chapter (Bureau of Mines Schedule 6D and Schedule 10C) are approved lamps for the purposes of § 75...

  9. 49 CFR 393.23 - Power supply for lamps.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 5 2013-10-01 2013-10-01 false Power supply for lamps. 393.23 Section 393.23... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.23 Power supply for lamps. All required lamps must be powered by the electrical system of the motor vehicle with the...

  10. 49 CFR 392.33 - Obscured lamps or reflective devices/material.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 5 2014-10-01 2014-10-01 false Obscured lamps or reflective devices/material. 392... REGULATIONS DRIVING OF COMMERCIAL MOTOR VEHICLES Use of Lighted Lamps and Reflectors § 392.33 Obscured lamps or reflective devices/material. (a) No commercial motor vehicle shall be driven when any of the lamps...

  11. 49 CFR 393.23 - Power supply for lamps.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 5 2012-10-01 2012-10-01 false Power supply for lamps. 393.23 Section 393.23... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.23 Power supply for lamps. All required lamps must be powered by the electrical system of the motor vehicle with the...

  12. 46 CFR 167.40-25 - Signaling lamp.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Signaling lamp. 167.40-25 Section 167.40-25 Shipping... Certain Equipment Requirements § 167.40-25 Signaling lamp. Nautical school ships of over 150 gross tons shall be equipped with an efficient signaling lamp. This lamp shall be permanently fixed above the...

  13. 46 CFR 167.40-25 - Signaling lamp.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Signaling lamp. 167.40-25 Section 167.40-25 Shipping... Certain Equipment Requirements § 167.40-25 Signaling lamp. Nautical school ships of over 150 gross tons shall be equipped with an efficient signaling lamp. This lamp shall be permanently fixed above the...

  14. 49 CFR 392.33 - Obscured lamps or reflective devices/material.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Obscured lamps or reflective devices/material. 392... REGULATIONS DRIVING OF COMMERCIAL MOTOR VEHICLES Use of Lighted Lamps and Reflectors § 392.33 Obscured lamps or reflective devices/material. (a) No commercial motor vehicle shall be driven when any of the lamps...

  15. 10 CFR 429.40 - Candelabra base incandescent lamps and intermediate base incandescent lamps.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Candelabra base incandescent lamps and intermediate base....40 Candelabra base incandescent lamps and intermediate base incandescent lamps. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to candelabra base...

  16. 10 CFR 429.40 - Candelabra base incandescent lamps and intermediate base incandescent lamps.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Candelabra base incandescent lamps and intermediate base....40 Candelabra base incandescent lamps and intermediate base incandescent lamps. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to candelabra base...

  17. 49 CFR 393.9 - Lamps operable, prohibition of obstructions of lamps and reflectors.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER... Electrical Wiring § 393.9 Lamps operable, prohibition of obstructions of lamps and reflectors. (a) All lamps... any part of the load, or its covering by dirt, or other added vehicle or work equipment, or otherwise...

  18. CALiPER Retail Lamps Study 3.1: Dimming, Flicker, and Power Quality Characteristics of LED A Lamps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2014-12-31

    This CALiPER report examines the characteristics of a subset of lamps from CALiPER Retail Lamps Study 3 in more detail. Specifically, it focuses on the dimming, power quality, and flicker characteristics of 14 LED A lamps, as controlled by four different retail-available dimmers.

  19. Guidelines for application of fluorescent lamps in high-performance avionic backlight systems

    NASA Astrophysics Data System (ADS)

    Syroid, Daniel D.

    1997-07-01

    Fluorescent lamps have proven to be well suited for use in high performance avionic backlight systems as demonstrated by numerous production applications for both commercial and military cockpit displays. Cockpit display applications include: Boeing 777, new 737s, F-15, F-16, F-18, F-22, C- 130, Navy P3, NASA Space Shuttle and many others. Fluorescent lamp based backlights provide high luminance, high lumen efficiency, precision chromaticity and long life for avionic active matrix liquid crystal display applications. Lamps have been produced in many sizes and shapes. Lamp diameters range from 2.6 mm to over 20 mm and lengths for the larger diameter lamps range to over one meter. Highly convoluted serpentine lamp configurations are common as are both hot and cold cathode electrode designs. This paper will review fluorescent lamp operating principles, discuss typical requirements for avionic grade lamps, compare avionic and laptop backlight designs and provide guidelines for the proper application of lamps and performance choices that must be made to attain optimum system performance considering high luminance output, system efficiency, dimming range and cost.

  20. Design and construction of a home-made and cheaper argon arc lamp

    NASA Astrophysics Data System (ADS)

    Sabaeian, Mohammad; Nazari-Tarkarani, Zeinab; Ebrahimzadeh, Azadeh

    2018-05-01

    The authors report on the design and construction of an argon arc lamp which provides noticeably a cheaper instrument for laser and medical applications. Cesium-doped tungsten and pure tungsten rods were used, respectively, for the lamp cathode and anode. To seal the glassy tube, a 50-50 Fe-Ni alloy was successfully used as a medium to attach the tungsten electrodes to the borosilicate glass tube. Starting voltage of the lamp versus the gas pressure, operation voltage-current diagram at various gas pressures, and lamp spectrum in the various pressures were measured. A comparison was made with krypton arc lamp. The lamp operation was satisfactory without any crack or fracture during lightening operation. The results showed that the lamp-lightening threshold voltage depends linearly on the pressure and arc length in such a way that there is an increase in the voltage by raising these two parameters. We have also observed that by increasing the argon pressure, there is a shifting in emission spectrum from the ultraviolet to the visible region. Comparison with krypton arc lamp indicated that argon lamp needs a higher threshold lightening voltage.