Rantalainen, Timo; Gastin, Paul B; Spangler, Rhys; Wundersitz, Daniel
2018-09-01
The purpose of the present study was to evaluate the concurrent validity and test-retest repeatability of torso-worn IMU-derived power and jump height in a counter-movement jump test. Twenty-seven healthy recreationally active males (age, 21.9 [SD 2.0] y, height, 1.76 [0.7] m, mass, 73.7 [10.3] kg) wore an IMU and completed three counter-movement jumps a week apart. A force platform and a 3D motion analysis system were used to concurrently measure the jumps and subsequently derive power and jump height (based on take-off velocity and flight time). The IMU significantly overestimated power (mean difference = 7.3 W/kg; P < 0.001) compared to force-platform-derived power but good correspondence between methods was observed (Intra-class correlation coefficient [ICC] = 0.69). IMU-derived power exhibited good reliability (ICC = 0.67). Velocity-derived jump heights exhibited poorer concurrent validity (ICC = 0.72 to 0.78) and repeatability (ICC = 0.68) than flight-time-derived jump heights, which exhibited excellent validity (ICC = 0.93 to 0.96) and reliability (ICC = 0.91). Since jump height and power are closely related, and flight-time-derived jump height exhibits excellent concurrent validity and reliability, flight-time-derived jump height could provide a more desirable measure compared to power when assessing athletic performance in a counter-movement jump with IMUs.
Shiovitz-Ezra, Sharon; Leitsch, Sara; Graber, Jessica; Karraker, Amelia
2009-11-01
The National Social Life, Health, and Aging Project (NSHAP) measures seven indicators of quality of life (QoL) and psychological health. The measures used for happiness, self-esteem, depression, and loneliness are well established in the literature. Conversely, measures of anxiety, stress, and self-reported emotional health were modified for their use in this unique project. The purpose of this paper is to provide (a) an overview of NSHAP's QoL assessment and (b) evidence for the adequacy of the modified measures. First, we examined the psychometric properties of the modified measures. Second, the established QoL measures were used to examine the concurrent validity of the modified measures. Finally, gender- and age-group differences were examined for each modified measure. The anxiety index exhibited good internal reliability and concurrent validity. Consistent with the literature, a single-factor structure best fit the data. Stress was satisfactory in terms of concurrent validity but with only fair internal consistency. Self-reported emotional health exhibited good concurrent validity and moderate external validity. The modified indices used in NSHAP tended to exhibit good internal reliability and concurrent validity. These measures can confidently be used in the exploration of QoL and psychological health in later life and its many correlates.
Toward Understanding Business Student Professional Development Engagement
ERIC Educational Resources Information Center
Blau, Gary; Blessley, Misty; Kunkle, Matthew; Schirmer, Michael; Regan, Laureen
2017-01-01
Professional development engagement (PDE) is defined as the level of perceived undergraduate engagement in professional development activities. An 11-item measure of PDE exhibited a good reliability. Using a complete data sample of 467 graduating business undergraduates, four variable sets (student background or precollege variables,…
A portable Fourier transform infrared gas analyzer with a photoacoustic detector performed reliably during pollution prevention research at two industrial facilities. It exhibited good agreement (within approximately 6%) with other analytical instruments (dispersive infrared and ...
Mayoral Del Moral, Orlando; Torres Lacomba, María; Russell, I Jon; Sánchez Méndez, Óscar; Sánchez Sánchez, Beatriz
2017-12-15
To determine whether two independent examiners can agree on a diagnosis of myofascial pain syndrome (MPS). To evaluate interexaminer reliability in identifying myofascial trigger points in upper quarter muscles. To evaluate the reliability of clinical diagnostic criteria for the diagnosis of MPS. To evaluate the validity of clinical diagnostic criteria for the diagnosis of MPS. Validity and reliability study. Provincial Hospital. Toledo, Spain. Twenty myofascial pain syndrome patients and 20 healthy, normal control subjects, enrolled by a trained and experienced examiner. Ten bilateral muscles from the upper quarter were evaluated by two experienced examiners. The second examiner was blinded to the diagnosis group. The MPS diagnosis required at least one muscle to have an active myofascial trigger point. Three to four days separated the two examinations. The primary outcome measure was the frequency with which the two examiners agreed on the classification of the subjects as patients or as healthy controls. The kappa statistic (K) was used to determine the level of agreement between both examinations, interpreted as very good (0.81-1.00), good (0.61-0.80), moderate (0.41-0.60), fair (0.21-0.40), or poor (≤0.20). Interexaminer reliability for identifying subjects with MPS was very good (K = 1.0). Interexaminer reliability for identifying muscles leading to a diagnosis of MPS was also very good (K = 0.81). Sensitivity and specificity showed high values for most examination tests in all muscles, which confirms the validity of clinical diagnostic criteria in the diagnosis of MPS. Interrater reliability between two expert examiners identifying subjects with MPS involving upper quarter muscles exhibited substantial agreement. These results suggest that clinical criteria can be valid and reliable in the diagnosis of this condition. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Wu, Juanjuan; Ye, Zhuo; Wu, Feng; Wang, Hongying; Zeng, Lintao; Bao, Guang-Ming
2018-05-01
Thiophenols are a class of highly toxic environmental pollutant, hence it is very necessary to monitor thiophenols in environment and living cells with an efficient and reliable method. Herein, a novel fluorescent probe for thiophenols has been developed, which exhibited a colorimetric and fluorescence turn-on dual response towards thiophenols with good selectivity and fast response. The sensing mechanism for thiophenols was attributed to nucleophilic substitution reaction, which was confirmed by HPLC. The probe exhibited good recovery (from 90% to 107%) and low limit of detection for thiophenols (37nM) in industrial wastewater. Moreover, the probe has been successfully employed to visualize thiophenol in living cells. Therefore, the fluorescent probe has good capability for monitoring thiophenols in environmental samples and biological systems. Copyright © 2018 Elsevier B.V. All rights reserved.
Assessing local instrument reliability and validity: a field-based example from northern Uganda.
Betancourt, Theresa S; Bass, Judith; Borisova, Ivelina; Neugebauer, Richard; Speelman, Liesbeth; Onyango, Grace; Bolton, Paul
2009-08-01
This paper presents an approach for evaluating the reliability and validity of mental health measures in non-Western field settings. We describe this approach using the example of our development of the Acholi psychosocial assessment instrument (APAI), which is designed to assess depression-like (two tam, par and kumu), anxiety-like (ma lwor) and conduct problems (kwo maraco) among war-affected adolescents in northern Uganda. To examine the criterion validity of this measure in the absence of a traditional gold standard, we derived local syndrome terms from qualitative data and used self reports of these syndromes by indigenous people as a reference point for determining caseness. Reliability was examined using standard test-retest and inter-rater methods. Each of the subscale scores for the depression-like syndromes exhibited strong internal reliability ranging from alpha = 0.84-0.87. Internal reliability was good for anxiety (0.70), conduct problems (0.83), and the pro-social attitudes and behaviors (0.70) subscales. Combined inter-rater reliability and test-retest reliability were good for most subscales except for the conduct problem scale and prosocial scales. The pattern of significant mean differences in the corresponding APAI problem scale score between self-reported cases vs. noncases on local syndrome terms was confirmed in the data for all of the three depression-like syndromes, but not for the anxiety-like syndrome ma lwor or the conduct problem kwo maraco.
A measure of satisfaction with food-related life.
Grunert, Klaus G; Dean, Moira; Raats, Monique M; Nielsen, Niels Asger; Lumbers, Margaret
2007-09-01
A measure of satisfaction with food-related life is developed and tested in three studies in eight European countries. Five items are retained from an original pool of seven; these items exhibit good reliability as measured by Cronbach's alpha, good temporal stability, convergent validity with two related measures, and construct validity as indicated by relationships with other indicators of quality of life, including the Satisfaction With Life and the SF-8 scales. It is concluded that this scale will be useful in studies trying to identify factors contributing to satisfaction with food-related life.
Rask, Marie; Oscarsson, Marie; Ludwig, Neil; Swahnberg, Katarina
2017-04-04
Cervical dysplasia is a precancerous condition, which has been shown to create anxiety in women. To be able to investigate these women's health-related quality of life, a disease-specific instrument is required. There does not seem to be a Swedish version of an instrument to screen for this specific disease. Therefore, this study aims to translate and cross-culturally adapt the Functional Assessment of Chronic Illness Therapy - Cervical Dysplasia (FACIT-CD) into a Swedish context and evaluate its linguistic validity and reliability. The Functional Assessment of Chronic Illness Therapy (FACIT) translation methodology was used, which consists of several steps including pilot testing of the FACIT-CD instrument through cognitive debriefing interviews. Ten women diagnosed with cervical dysplasia participated in the cognitive debriefing interviews. The internal consistency reliability of the Swedish FACIT-CD was estimated by Cronbach's alpha coefficient. Homogeneity of the items was evaluated by corrected item-total correlations. The sample consists of 34 women who were diagnosed with cervical dysplasia. The translation and cross-cultural adaptation went smoothly without any problems for the majority of the items. The cognitive debriefing interviews indicated that the Swedish FACIT-CD consists of relevant items, is easy to understand and complete, and has unambiguous and comprehensive response categories. The translation and cross-cultural adaptation resulted in a Swedish FACIT-CD, which is conceptually and semantically equivalent to the English version and linguistically valid. The total scale of the Swedish FACIT-CD exhibited good internal consistency reliability with a Cronbach's alpha coefficient of 0.84, and all of the subscales exhibited acceptable value between 0.71 and 0.81 except the Relationships subscale, which had a value of 0.67. Finally, all but four items exceeded the acceptable level for the corrected item-total correlations of ≥ 0.20. The Swedish FACIT-CD is conceptually and semantically equivalent to the English version and linguistically valid; further, it exhibits good internal consistency reliability.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Hongying, E-mail: liuhongying@hdu.edu.cn; Gu, Chunchuan; Li, Dujuan
Graphical abstract: A non-enzymatic H{sub 2}O{sub 2} sensor with high selectivity and sensitivity based on rose-shaped FeMoO{sub 4} synthesized by the convenient microwave-assisted hydrothermal method, was fabricated. - Highlights: • Rose-shaped FeMoO{sub 4} is synthesized within 10 min via microwave-assisted hydrothermal approach. • Non-enzymatic hydrogen peroxide biosensor based on FeMoO{sub 4} nanomaterials is fabricated. • The biosensor exhibits good performance. - Abstract: In this work, we demonstrated a simple, rapid and reliable microwave-assisted hydrothermal approach to synthesize the uniform rose-shaped FeMoO{sub 4} within 10 min. The morphologies of the synthesized materials were characterized by X-ray powder diffraction and scanning electronmore » microscopy. Moreover, a non-enzymatic amperometric sensor for the detection of hydrogen peroxide (H{sub 2}O{sub 2}) was fabricated on the basis of the FeMoO{sub 4} as electrocatalysis. The resulting FeMoO{sub 4} exhibited high sensitivity and good stability for the detection of H{sub 2}O{sub 2}, which may be attributed to the rose-shaped structure of the material and the catalytic property of FeMoO{sub 4}. Amperometric response showed that the modified electrode had a good response for H{sub 2}O{sub 2} with a linear range from 1 μM to 1.6 mM, a detection limit of 0.5 μM (S/N = 3), high selectivity and short response time. Additionally, good recoveries of analytes in real milk samples confirm the reliability of the prepared sensor in practical applications.« less
Zanto, Theodore P; Pa, Judy; Gazzaley, Adam
2014-01-01
As the aging population grows, it has become increasingly important to carefully characterize amnestic mild cognitive impairment (aMCI), a preclinical stage of Alzheimer's disease (AD). Functional magnetic resonance imaging (fMRI) is a valuable tool for monitoring disease progression in selectively vulnerable brain regions associated with AD neuropathology. However, the reliability of fMRI data in longitudinal studies of older adults with aMCI is largely unexplored. To address this, aMCI participants completed two visual working tasks, a Delayed-Recognition task and a One-Back task, on three separate scanning sessions over a three-month period. Test-retest reliability of the fMRI blood oxygen level dependent (BOLD) activity was assessed using an intraclass correlation (ICC) analysis approach. Results indicated that brain regions engaged during the task displayed greater reliability across sessions compared to regions that were not utilized by the task. During task-engagement, differential reliability scores were observed across the brain such that the frontal lobe, medial temporal lobe, and subcortical structures exhibited fair to moderate reliability (ICC=0.3-0.6), while temporal, parietal, and occipital regions exhibited moderate to good reliability (ICC=0.4-0.7). Additionally, reliability across brain regions was more stable when three fMRI sessions were used in the ICC calculation relative to two fMRI sessions. In conclusion, the fMRI BOLD signal is reliable across scanning sessions in this population and thus a useful tool for tracking longitudinal change in observational and interventional studies in aMCI. © 2013.
Litzenburger, Friederike; Heck, Katrin; Pitchika, Vinay; Neuhaus, Klaus W; Jost, Fabian N; Hickel, Reinhard; Jablonski-Momeni, Anahita; Welk, Alexander; Lederer, Alexander; Kühnisch, Jan
2018-02-01
The purpose of this in vitro study was to evaluate the inter- and intraexaminer reliability of digital bitewing (DBW) radiography and near-infrared light transillumination (NIRT) for proximal caries detection and assessment in posterior teeth. From a pool of 85 patients, 100 corresponding pairs of DBW and NIRT images (~1/3 healthy, ~1/3 with enamel caries and ~1/3 with dentin caries) were chosen. 12 dentists with different professional status and clinical experience repeated the evaluation in two blinded cycles. Two experienced dentists provided a reference diagnosis after analysing all images independently. Statistical analysis included the calculation of simple (κ) and weighted Kappa (wκ) values as a measure of reliability. Logistic regression with a backward elimination model was used to investigate the influence of the diagnostic method, evaluation cycle, type of tooth, and clinical experience on reliability. Altogether, inter- and intraexaminer reliability exhibited good to excellent κ and wκ values for DBW radiography (Inter: κ = 0.60/ 0.63; wκ = 0.74/0.76; Intra: κ = 0.64; wκ = 0.77) and NIRT (Inter: κ = 0.74/0.64; wκ = 0.86/0.82; Intra: κ = 0.68; wκ = 0.84). The backward elimination model revealed NIRT to be significantly more reliable than DBW radiography. This study revealed a good to excellent inter- and intraexaminer reliability for proximal caries detection using DBW and NIRT images. The logistic regression analysis revealed significantly better reliability for NIRT. Additionally, the first evaluation cycle was more reliable according to the reference diagnoses.
A Simple and Reliable Method of Design for Standalone Photovoltaic Systems
NASA Astrophysics Data System (ADS)
Srinivasarao, Mantri; Sudha, K. Rama; Bhanu, C. V. K.
2017-06-01
Standalone photovoltaic (SAPV) systems are seen as a promoting method of electrifying areas of developing world that lack power grid infrastructure. Proliferations of these systems require a design procedure that is simple, reliable and exhibit good performance over its life time. The proposed methodology uses simple empirical formulae and easily available parameters to design SAPV systems, that is, array size with energy storage. After arriving at the different array size (area), performance curves are obtained for optimal design of SAPV system with high amount of reliability in terms of autonomy at a specified value of loss of load probability (LOLP). Based on the array to load ratio (ALR) and levelized energy cost (LEC) through life cycle cost (LCC) analysis, it is shown that the proposed methodology gives better performance, requires simple data and is more reliable when compared with conventional design using monthly average daily load and insolation.
Israel, Benjamin; Buysse, Daniel J; Krafty, Robert T; Begley, Amy; Miewald, Jean; Hall, Martica
2012-09-01
Quantify the short-term stability of multiple indices of sleep and nocturnal physiology in good sleeper controls and primary insomnia patients. Intra-class correlation coefficients (ICC) were used to quantify the short-term stability of study outcomes. Sleep laboratory. Fifty-four adults with primary insomnia (PI) and 22 good sleeper controls (GSC). Visually scored sleep outcomes included indices of sleep duration, continuity, and architecture. Quantitative EEG outcomes included power in the delta, theta, alpha, sigma, and beta bands during NREM sleep. Power spectral analysis was used to estimate high-frequency heart rate variability (HRV) and the ratio of low- to high-frequency HRV power during NREM and REM sleep. With the exception of percent stage 3+4 sleep; visually scored sleep outcomes did not exhibit short-term stability across study nights. Most QEEG outcomes demonstrated short-term stability in both groups. Although power in the beta band was stable in the PI group (ICC = 0.75), it tended to be less stable in GSCs (ICC = 0.55). Both measures of cardiac autonomic tone exhibited short-term stability in GSCs and PIs during NREM and REM sleep. Most QEEG bandwidths and HRV during sleep show high short-term stability in good sleepers and patients with insomnia alike. One night of data is, thus, sufficient to derive reliable estimates of these outcomes in studies focused on group differences or correlates of QEEG and/or HRV. In contrast, one night of data is unlikely to generate reliable estimates of PSG-assessed sleep duration, continuity or architecture, with the exception of slow wave sleep.
Preliminary validation of the Yale Food Addiction Scale.
Gearhardt, Ashley N; Corbin, William R; Brownell, Kelly D
2009-04-01
Previous research has found similarities between addiction to psychoactive substances and excessive food consumption. Further exploration is needed to evaluate the concept of "food addiction," as there is currently a lack of psychometrically validated measurement tools in this area. The current study represents a preliminary exploration of the Yale Food Addiction Scale (YFAS), designed to identify those exhibiting signs of addiction towards certain types of foods (e.g., high fat and high sugar). Survey data were collected from 353 respondents from a stratified random sample of young adults. In addition to the YFAS, the survey assessed eating pathology, alcohol consumption and other health behaviors. The YFAS exhibited adequate internal reliability, and showed good convergent validity with measures of similar constructs and good discriminant validity relative to related but dissimilar constructs. Additionally, the YFAS predicted binge-eating behavior above and beyond existing measures of eating pathology, demonstrating incremental validity. The YFAS is a sound tool for identifying eating patterns that are similar to behaviors seen in classic areas of addiction. Further evaluation of the scale is needed, especially due to a low response rate of 24.5% and a non-clinical sample, but confirmation of the reliability and validity of the scale has the potential to facilitate empirical research on the concept of "food addiction".
Cruz, Jonas Preposi; Alquwez, Nahed; Alqubeilat, Hikmet; Colet, Paolo C
2016-05-22
To evaluate the psychometric properties of the Spiritual Coping Strategies scale Arabic version (SCS-A) in a sample of nursing students in Saudi Arabia. This study had a cross-sectional design with a convenience sample of 100 nursing students in Saudi Arabia. Using the SCS-A and the Muslim Religiosity Scale for data collection, data were analyzed to establish the reliability and validity of the SCS-A. Good internal consistency reliability (Cronbach's α > .70) and stability reliability (intraclass correlation coefficient > .80) were observed. Two dominant factors were extracted from the scale items, the nonreligious coping strategies and religious coping strategies, which accounted for 35.5% and 32.7% of the variance, respectively. The religious coping subscale exhibited a strong positive correlation with the religious practices subscale of the Muslim Religious Involvement Scale (r = .45, p < .001) and total religiosity score (r = .48, p < .001) as well as a weak positive correlation with the intrinsic religious beliefs subscale (r = .25, p < .05). No significant relationship was found between nonreligious coping subscale and the Muslim Religious Involvement Scale. The SCS-A exhibited an acceptable validity and reliability, supporting its sound psychometric properties with respect to the responses from Saudi nursing students. © The Author(s) 2016.
Simões, Luan; Teixeira-Salmela, Luci Fuscaldi; Magalhães, Lívia; Stuge, Britt; Laurentino, Glória; Wanderley, Elaine; Barros, Raphaela; Lemos, Andrea
2018-04-24
The purpose of this study was to evaluate test-retest reliability, construct validity, and internal consistency of the Brazilian version of the Pelvic Girdle Questionnaire (PGQ-Brazil). Analysis of the measurement properties was carried out in 4 steps. Step 1 was the pilot study, on which basis 4 hypotheses were formulated. These hypotheses were tested during the next step (construct validity, step 2) by completion of the questionnaire by the 2 groups (in pain [n = 105] and not in pain [n = 52]). For implementation of the PGQ-Brazil in the group with pain, we calculated the internal consistency (step 3) and, 7 days later, test-retest reliability (step 4) by re-application of the instrument in this group. First, the PGQ-Brazil was able to discriminate between these groups (construct validity). Second, test-retest reliability (intraclass correlation coefficients for Activities subscale [0.97 with 95% confidence interval of 0.95-0.98] and Symptoms subscale [0.98 with 95% confidence interval of 0.97-0.98] and κ coefficient between 0.50 and 0.89 for the items) was found to be good; the Bland-Altman test indicated satisfactory agreement. The Rasch analysis indicated good internal consistency, and the instrument's ability to divide the participants into at least 3 levels of skills was confirmed. In contrast, a ceiling effect was observed, as 24% of pregnant women exhibited skills superior to what the PGQ-Brazil could evaluate. The PGQ-Brazil had good internal consistency, test-retest reliability, and construct validity in assessment of limitations in activities and symptoms of pregnant women with pelvic girdle pain. Copyright © 2018. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Yang, Xiaojun; Zhu, Xiaofei; Deng, Chi; Li, Junyi; Liu, Cheng; Yu, Wenpeng; Luo, Hui
2017-10-01
To improve the level of management and monitoring of leakage and abnormal disturbance of long distance oil pipeline, the distributed optical fiber temperature and vibration sensing system is employed to test the feasibility for the healthy monitoring of a domestic oil pipeline. The simulating leakage and abnormal disturbance affairs of oil pipeline are performed in the experiment. It is demonstrated that the leakage and abnormal disturbance affairs of oil pipeline can be monitored and located accurately with the distributed optical fiber sensing system, which exhibits good performance in the sensitivity, reliability, operation and maintenance etc., and shows good market application prospect.
Defense AT and L. Volume 38, Number 4
2009-06-01
accuracy at extended ranges. Today, Afghanistan- and Iraq-bound medics get realistic training on a Florida-based company’s Mini-Combat Trauma Patient ...school basketball team and drone on about how we miss 100 percent of the shots we don’t take. Fine. They may be right; failure might be good for us...be developed (or procured) that exhibits high inherent reliability and maintainability plus ad- vanced self- diagnostics . Do the ICD and Gate 1
Inter-rater reliability of kinesthetic measurements with the KINARM robotic exoskeleton.
Semrau, Jennifer A; Herter, Troy M; Scott, Stephen H; Dukelow, Sean P
2017-05-22
Kinesthesia (sense of limb movement) has been extremely difficult to measure objectively, especially in individuals who have survived a stroke. The development of valid and reliable measurements for proprioception is important to developing a better understanding of proprioceptive impairments after stroke and their impact on the ability to perform daily activities. We recently developed a robotic task to evaluate kinesthetic deficits after stroke and found that the majority (~60%) of stroke survivors exhibit significant deficits in kinesthesia within the first 10 days post-stroke. Here we aim to determine the inter-rater reliability of this robotic kinesthetic matching task. Twenty-five neurologically intact control subjects and 15 individuals with first-time stroke were evaluated on a robotic kinesthetic matching task (KIN). Subjects sat in a robotic exoskeleton with their arms supported against gravity. In the KIN task, the robot moved the subjects' stroke-affected arm at a preset speed, direction and distance. As soon as subjects felt the robot begin to move their affected arm, they matched the robot movement with the unaffected arm. Subjects were tested in two sessions on the KIN task: initial session and then a second session (within an average of 18.2 ± 13.8 h of the initial session for stroke subjects), which were supervised by different technicians. The task was performed both with and without the use of vision in both sessions. We evaluated intra-class correlations of spatial and temporal parameters derived from the KIN task to determine the reliability of the robotic task. We evaluated 8 spatial and temporal parameters that quantify kinesthetic behavior. We found that the parameters exhibited moderate to high intra-class correlations between the initial and retest conditions (Range, r-value = [0.53-0.97]). The robotic KIN task exhibited good inter-rater reliability. This validates the KIN task as a reliable, objective method for quantifying kinesthesia after stroke.
The reliability, validity, and accuracy of self-reported absenteeism from work: a meta-analysis.
Johns, Gary; Miraglia, Mariella
2015-01-01
Because of a variety of access limitations, self-reported absenteeism from work is often employed in research concerning health, organizational behavior, and economics, and it is ubiquitous in large scale population surveys in these domains. Several well established cognitive and social-motivational biases suggest that self-reports of absence will exhibit convergent validity with records-based measures but that people will tend to underreport the behavior. We used meta-analysis to summarize the reliability, validity, and accuracy of absence self-reports. The results suggested that self-reports of absenteeism offer adequate test-retest reliability and that they exhibit reasonably good rank order convergence with organizational records. However, people have a decided tendency to underreport their absenteeism, although such underreporting has decreased over time. Also, self-reports were more accurate when sickness absence rather than absence for any reason was probed. It is concluded that self-reported absenteeism might serve as a valid measure in some correlational research designs. However, when accurate knowledge of absolute absenteeism levels is essential, the tendency to underreport could result in flawed policy decisions. PsycINFO Database Record (c) 2014 APA, all rights reserved.
Development of an empirical typology of African American family functioning.
Mandara, Jelani; Murray, Carolyn B
2002-09-01
This study empirically identified types of African American families. Adolescents (N = 111) were assessed on family functioning. With cluster analytic methods, 3 types of families were identified. The cohesive-authoritative type was above average on parental education and income, averaged about 2 children, exhibited a high quality of family functioning and high self-esteem in adolescents. The conflictive-authoritarian type had average parental education and income, an average of 2.7 children, exhibited controlling and rigid discipline, and placed a high emphasis on achievement. The defensive-neglectful type was predominately headed by single mothers with below average education and income and averaged about 3 children. Such families displayed chaotic family processes, and adolescents tended to suffer from low self-esteem. The typology exhibited good reliability. The implications of the typology are discussed.
NASA Astrophysics Data System (ADS)
Chen, Wenjun; Deng, Dunying; Cheng, Yuanrong; Xiao, Fei
2015-07-01
The easy oxidation of copper is one critical obstacle to high-performance copper-filled isotropically conductive adhesives (ICAs). In this paper, a facile method to prepare highly reliable, highly conductive, and low-cost ICAs is reported. The copper fillers were treated by organic acids for oxidation prevention. Compared with ICA filled with untreated copper flakes, the ICA filled with copper flakes treated by different organic acids exhibited much lower bulk resistivity. The lowest bulk resistivity achieved was 4.5 × 10-5 Ω cm, which is comparable to that of commercially available Ag-filled ICA. After 500 h of 85°C/85% relative humidity (RH) aging, the treated ICAs showed quite stable bulk resistivity and relatively stable contact resistance. Through analyzing the results of x-ray diffraction, x-ray photoelectron spectroscopy, and thermogravimetric analysis, we found that, with the assistance of organic acids, the treated copper flakes exhibited resistance to oxidation, thus guaranteeing good performance.
Lu, Wei; Bian, Qian; Wang, Wenzheng; Wu, Xiaoling; Wang, Zhen; Zhao, Min
2017-01-01
Chinese university students often suffer from acute stress, which can affect their mental health. We measured and evaluated perceived stress in this population using the Simplified Chinese version of the 10-item Perceived Stress Scale (SCPSS-10). The SCPSS-10, Patient Health Questionnaire (PHQ), and Generalized Anxiety Disorder 7-item scale (GAD-7) were conducted in 1096 university students. Two weeks later, 129 participants were re-tested using the SCPSS-10. Exploratory factor analysis yielded two factors with Eigen values of 4.76 and 1.48, accounting for 62.41% of the variance. Confirmatory factor analysis demonstrated good fit of this two-factor model. The internal consistency reliability, as measured by Cronbach's α, was 0.85. The test-retest reliability coefficient was 0.7. The SCPSS-10 exhibited high correlation with the PHQ-9 and GAD-7, indicating an acceptable concurrent validity. The SCPSS-10 exhibited satisfactory psychometric properties in Chinese university students.
Cordier, Reinie; Speyer, Renée; Schindler, Antonio; Michou, Emilia; Heijnen, Bas Joris; Baijens, Laura; Karaduman, Ayşe; Swan, Katina; Clavé, Pere; Joosten, Annette Veronica
2018-02-01
The Swallowing Quality of Life questionnaire (SWAL-QOL) is widely used clinically and in research to evaluate quality of life related to swallowing difficulties. It has been described as a valid and reliable tool, but was developed and tested using classic test theory. This study describes the reliability and validity of the SWAL-QOL using item response theory (IRT; Rasch analysis). SWAL-QOL data were gathered from 507 participants at risk of oropharyngeal dysphagia (OD) across four European countries. OD was confirmed in 75.7% of participants via videofluoroscopy and/or fiberoptic endoscopic evaluation, or a clinical diagnosis based on meeting selected criteria. Patients with esophageal dysphagia were excluded. Data were analysed using Rasch analysis. Item and person reliability was good for all the items combined. However, person reliability was poor for 8 subscales and item reliability was poor for one subscale. Eight subscales exhibited poor person separation and two exhibited poor item separation. Overall item and person fit statistics were acceptable. However, at an individual item fit level results indicated unpredictable item responses for 28 items, and item redundancy for 10 items. The item-person dimensionality map confirmed these findings. Results from the overall Rasch model fit and Principal Component Analysis were suggestive of a second dimension. For all the items combined, none of the item categories were 'category', 'threshold' or 'step' disordered; however, all subscales demonstrated category disordered functioning. Findings suggest an urgent need to further investigate the underlying structure of the SWAL-QOL and its psychometric characteristics using IRT.
Bean, Donna L; Rotheram-Borus, Mary Jane; Leibowitz, Arleen; Horwitz, Sarah M; Weidmer, Beverly
2003-02-01
To assess test-retest reliability of the service utilization screening section of the Services Assessment for Children and Adolescents (SACA) interview among Spanish-speaking parents and adolescents, correspondence between parent and adolescent reports, and the correlation between reliability and participants' demographic and service use characteristics. The English SACA was translated and administered from September 1999 through January 2000 in Los Angeles County, California, on two separate occasions to eligible parents with a child (4-17 years old) who was a client of a local public mental health authority. Adolescents of these parents (12-17 years old) were also interviewed. Reliability was measured by the kappa statistic. Adult and adolescent reports about lifetime and previous year service setting use exhibited good reliability, but concordance of parents and adolescents did not. Children's service utilization appears to be correlated with reliability of parent reports, and child gender appears to be correlated with reliability of adolescent reports. The SACA appears to be a useful tool for screening Spanish-speaking families about child and adolescent mental health service use. These findings must be considered preliminary until replicated in a larger sample of culturally diverse Spanish-speaking families.
Battaglia, Patrick J; Mattox, Ross; Winchester, Brett; Kettner, Norman W
The primary aim of this study was to determine the reliability of diagnostic ultrasound imaging for select intrinsic foot muscles using both non-weight-bearing and weight-bearing postures. Our secondary aim was to describe the change in muscle cross-sectional area (CSA) and dorsoplantar thickness when bearing weight. An ultrasound examination was performed with a linear ultrasound transducer operating between 9 and 12 MHz. Long-axis and short-axis ultrasound images of the abductor hallucis, flexor digitorum brevis, and quadratus plantae were obtained in both the non-weight-bearing and weight-bearing postures. Two examiners independently collected ultrasound images to allow for interexaminer and intraexaminer reliability calculation. The change in muscle CSA and dorsoplantar thickness when bearing weight was also studied. There were 26 participants (17 female) with a mean age of 25.5 ± 3.8 years and a mean body mass index of 28.0 ± 7.8 kg/m 2 . Inter-examiner reliability was excellent when measuring the muscles in short axis (intraclass correlation coefficient >0.75) and fair to good in long axis (intraclass correlation coefficient >0.4). Intraexaminer reliability was excellent for the abductor hallucis and flexor digitorum brevis and ranged from fair to good to excellent for the quadratus plantae. Bearing weight did not reduce interexaminer or intraexaminer reliability. All muscles exhibited a significant increase in CSA when bearing weight. This is the first report to describe weight-bearing diagnostic ultrasound of the intrinsic foot muscles. Ultrasound imaging is reliable when imaging these muscles bearing weight. Furthermore, muscle CSA increases in the weight-bearing posture. Copyright © 2016. Published by Elsevier Inc.
Reliability Studies of Ceramic Capacitors.
1983-07-01
increases. This case has been found to be a good approximation for single crystals with high chemical and structural purity. Shallow traps may arise as a...theory, this sudden increase may be otherwise explained. Single crystals of ZnS have been found to exhibit this vertical increase in the current...Smith and Rose observed SCLC behavior in CdS single crystals . Branwood and Tredgold 2 8 and Branwood et al. 2 9 measured BaTiO 3 single crystals and
Tadakamadla, Santosh Kumar; Quadri, Mir Faeq Ali; Pakpour, Amir H; Zailai, Abdulaziz M; Sayed, Mohammed E; Mashyakhy, Mohammed; Inamdar, Aadil S; Tadakamadla, Jyothi
2014-09-29
To evaluate the reliability and validity of Arabic Rapid Estimate of Adult Literacy in Dentistry (AREALD-30) in Saudi Arabia. A convenience sample of 200 subjects was approached, of which 177 agreed to participate giving a response rate of 88.5%. Rapid Estimate of Adult Literacy in Dentistry (REALD-99), was translated into Arabic to prepare the longer and shorter versions of Arabic Rapid Estimate of Adult Literacy in Dentistry (AREALD-99 and AREALD-30). Each participant was provided with AREALD-99 which also includes words from AREALD-30. A questionnaire containing socio-behavioral information and Arabic Oral Health Impact Profile (A-OHIP-14) was also administered. Reliability of the AREALD-30 was assessed by re-administering it to 20 subjects after two weeks. Convergent and predictive validity of AREALD-30 was evaluated by its correlations with AREALD-99 and self-perceived oral health status, dental visiting habits and A-OHIP-14 respectively. Discriminant validity was assessed in relation to the educational level while construct validity was evaluated by confirmatory factor analysis (CFA). Reliability of AREALD-30 was excellent with intraclass correlation coefficient of 0.99. It exhibited good convergent and discriminant validity but poor predictive validity. CFA showed presence of two factors and infit mean-square statistics for AREALD-30 were all within the desired range of 0.50 - 2.0 in Rasch analysis. AREALD-30 showed excellent reliability, good convergent and concurrent validity, but failed to predict the differences between the subjects categorized based on their oral health outcomes.
Yao, Min; Yang, Long; Cao, Zuo-Yuan; Cheng, Shao-Dan; Tian, Shuang-Lin; Sun, Yue-Li; Wang, Jing; Xu, Bao-Ping; Hu, Xiao-Chun; Wang, Yong-Jun; Zhang, Ying; Cui, Xue-Jun
2017-09-18
Shoulder pain is a common musculoskeletal disorder in Chinese population, which affects more than 1,3 billion individuals. To the best of our knowledge, there has been no available Chinese-language version of measurements of shoulder pain and disability so far. Moreover, the Constant-Murley score (CMS) questionnaire is a universally recognized patient-reported questionnaire for clinical practice and research. The present study was designed to evaluate a Chinese translational version of CMS and subsequently assess its reliability and validity. The Chinese translational version of CMS was formulated by means of forward-backward translation. Meanwhile, a final review was carried out by an expert committee, followed by conducting a test of the pre-final version. Therefore, the reliability and validity of the Chinese translational version of CMS could be assessed using the internal consistency, construct validity, factor analysis, reliability and floor and ceiling effects. Specifically, the reliability was assessed by testing the internal consistency (Cronbach's α) and test-retest reliability (intraclass coefficient correlation [ICC]), while the construct validity was evaluated via comparison between the Chinese translational version of CMS with visual analog scale (VAS) score and the 36-Item Short Form Health Survey (SF-36, Spearman correlation). The questionnaire was verified to be acceptable after distribution among 120 subjects with unilateral shoulder pain. Factor analysis had revealed a two-factor and 10-item solution. Moreover, the assessment results indicated that the Chinese translational version of CMS questionnaire harbored good internal consistency (Cronbach's α = 0.739) and test-retest reliability (ICC = 0.827). In addition, the Chinese translational version of CMS was moderately correlated with VAS score (r = 0.497) and SF-36 (r = 0.135). No obvious floor and ceiling effects were observed in the Chinese translational version of CMS questionnaire. Chinese translational version of CMS exhibited good reliability, which is relatively acceptable and is likely to be widely used in this population.
Dalton, Michelle; Hollingworth, Sophie; Blundell, John; Finlayson, Graham
2015-09-04
Some individuals exhibit a weak satiety response to food and may be susceptible to overconsumption. The current study identified women showing consistently low or high satiety responses to standardised servings of food across four separate days and compared them on behavioural, psychological and physiological risk factors for overeating and future weight gain. In a crossover design, 30 female participants (age: 28.0 ± 10.6; body mass index (BMI): 23.1 ± 3.0) recorded sensations of hunger in the post-prandial period following four graded energy level breakfasts. Satiety quotients were calculated to compare individuals on satiety responsiveness across conditions. Body composition, resting metabolic rate (RMR), energy intake, food reward and craving, and eating behaviour traits were assessed under controlled laboratory conditions. A distinct low satiety phenotype (LSP) was identified with good consistency across separate study days. These individuals had a higher RMR, greater levels of disinhibition and reported feeling lower control over food cravings. Further, they consumed more energy and exhibited greater wanting for high-fat food. The inverse pattern of characteristics was observed in those exhibiting a consistently high satiety phenotype (HSP). Weak satiety responsiveness is a reliable trait identifiable using the satiety quotient. The LSP was characterised by distinct behavioural and psychological characteristics indicating a risk for overeating, compared to HSP.
Thibodeau, Michel A; Leonard, Rachel C; Abramowitz, Jonathan S; Riemann, Bradley C
2015-12-01
The Dimensional Obsessive-Compulsive Scale (DOCS) is a promising measure of obsessive-compulsive disorder (OCD) symptoms but has received minimal psychometric attention. We evaluated the utility and reliability of DOCS scores. The study included 832 students and 300 patients with OCD. Confirmatory factor analysis supported the originally proposed four-factor structure. DOCS total and subscale scores exhibited good to excellent internal consistency in both samples (α = .82 to α = .96). Patient DOCS total scores reduced substantially during treatment (t = 16.01, d = 1.02). DOCS total scores discriminated between students and patients (sensitivity = 0.76, 1 - specificity = 0.23). The measure did not exhibit gender-based differential item functioning as tested by Mantel-Haenszel chi-square tests. Expected response options for each item were plotted as a function of item response theory and demonstrated that DOCS scores incrementally discriminate OCD symptoms ranging from low to extremely high severity. Incremental differences in DOCS scores appear to represent unbiased and reliable differences in true OCD symptom severity. © The Author(s) 2014.
Fast Setting Silk Fibroin Bioink for Bioprinting of Patient-Specific Memory-Shape Implants.
Costa, João B; Silva-Correia, Joana; Oliveira, Joaquim M; Reis, Rui L
2017-11-01
The pursuit for the "perfect" biomimetic and personalized implant for musculoskeletal tissue regeneration remains a big challenge. 3D printing technology that makes use of a novel and promising biomaterials can be part of the solution. In this study, a fast setting enzymatic-crosslinked silk fibroin (SF) bioink for 3D bioprinting is developed. Their properties are fine-tuned and different structures with good resolution, reproducibility, and reliability can be fabricated. Many potential applications exist for the SF bioinks including 3D bioprinted scaffolds and patient-specific implants exhibiting unique characteristics such as good mechanical properties, memory-shape feature, suitable degradation, and tunable pore architecture and morphology. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Jung, Julia; Nitzsche, Anika; Neumann, Melanie; Wirtz, Markus; Kowalski, Christoph; Wasem, Jürgen; Stieler-Lorenz, Brigitte; Pfaff, Holger
2010-09-13
The Worksite Health Promotion Capacity Instrument (WHPCI) was developed to assess two key factors for effective worksite health promotion: collective willingness and the systematic implementation of health promotion activities in companies. This study evaluates the diagnostic qualities of the WHPCI based on its subscales Health Promotion Willingness and Health Promotion Management, which can be used to place companies into four different categories based on their level of health promotion capacity. Psychometric evaluation was conducted using exploratory factor and reliability analyses with data taken from a random sample of managers from n = 522 German information and communication technology (ICT) companies. Receiver operating characteristic (ROC) analyses were conducted to determine further diagnostic qualities of the instrument and to establish the cut-off scores used to determine each company's level of health promotion capacity. The instrument's subscales, Health Promotion Willingness and Health Promotion Management, are based on one-dimensional constructs, each with very good reliability (Cronbach's alpha = 0.83/0.91). ROC analyses demonstrated satisfactory diagnostic accuracy with an area under the curve (AUC) of 0.76 (SE = 0.021; 95% CI 0.72-0.80) for the Health Promotion Willingness scale and 0.81 (SE = 0.021; 95% CI 0.77-0.86) for the Health Promotion Management scale. A cut-off score with good sensitivity (71%/76%) and specificity (69%/75%) was determined for each scale. Both scales were found to have good predictive power and exhibited good efficiency. Our findings indicate preliminary evidence for the validity and reliability of both subscales of the WHPCI. The goodness of each cut-off score suggests that the scales are appropriate for determining companies' levels of health promotion capacity. Support in implementing (systematic) worksite health promotion can then be tailored to each company's needs based on their current capacity level.
Test-Retest Reliability of Graph Metrics in Functional Brain Networks: A Resting-State fNIRS Study
Niu, Haijing; Li, Zhen; Liao, Xuhong; Wang, Jinhui; Zhao, Tengda; Shu, Ni; Zhao, Xiaohu; He, Yong
2013-01-01
Recent research has demonstrated the feasibility of combining functional near-infrared spectroscopy (fNIRS) and graph theory approaches to explore the topological attributes of human brain networks. However, the test-retest (TRT) reliability of the application of graph metrics to these networks remains to be elucidated. Here, we used resting-state fNIRS and a graph-theoretical approach to systematically address TRT reliability as it applies to various features of human brain networks, including functional connectivity, global network metrics and regional nodal centrality metrics. Eighteen subjects participated in two resting-state fNIRS scan sessions held ∼20 min apart. Functional brain networks were constructed for each subject by computing temporal correlations on three types of hemoglobin concentration information (HbO, HbR, and HbT). This was followed by a graph-theoretical analysis, and then an intraclass correlation coefficient (ICC) was further applied to quantify the TRT reliability of each network metric. We observed that a large proportion of resting-state functional connections (∼90%) exhibited good reliability (0.6< ICC <0.74). For global and nodal measures, reliability was generally threshold-sensitive and varied among both network metrics and hemoglobin concentration signals. Specifically, the majority of global metrics exhibited fair to excellent reliability, with notably higher ICC values for the clustering coefficient (HbO: 0.76; HbR: 0.78; HbT: 0.53) and global efficiency (HbO: 0.76; HbR: 0.70; HbT: 0.78). Similarly, both nodal degree and efficiency measures also showed fair to excellent reliability across nodes (degree: 0.52∼0.84; efficiency: 0.50∼0.84); reliability was concordant across HbO, HbR and HbT and was significantly higher than that of nodal betweenness (0.28∼0.68). Together, our results suggest that most graph-theoretical network metrics derived from fNIRS are TRT reliable and can be used effectively for brain network research. This study also provides important guidance on the choice of network metrics of interest for future applied research in developmental and clinical neuroscience. PMID:24039763
Beardsley, Chris; Egerton, Tim; Skinner, Brendon
2016-01-01
Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI) for measuring sagittal plane pelvic tilt in 18 young, healthy males and females. Method. The inter-rater reliability and test-re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart. Results. For measuring pelvic tilt, inter-rater reliability was designated as good on both sides (ICC = 0.81-0.88), test-re-test reliability within a single rating session was designated as good on both sides (ICC = 0.88-0.95), and test-re-test reliability between two rating sessions was designated as moderate on the left side (ICC = 0.65) and good on the right side (ICC = 0.85). Conclusion. Inter-rater reliability and test-re-test reliability within a single rating session of the DPI in measuring pelvic tilt were both good, while test-re-test reliability between rating sessions was moderate-to-good. Caution is required regarding the interpretation of the test-re-test reliability within a single rating session, as the raters were not blinded. Further research is required to establish validity.
Using temperature-switching approach to evaluate the ELDRS of bipolar devices
NASA Astrophysics Data System (ADS)
Li, Xiaolong; Lu, Wu; Wang, Xin; Guo, Qi; Yu, Xin; He, Chengfa; Sun, Jing; Liu, Mohan; Yao, Shuai; Wei, Xinyu
2017-12-01
Enhanced low-dose rate sensitivity (ELDRS) exhibited at low-dose rates (LDRs) by most bipolar devices is considered as one of the main concerns for spacecraft reliability. In this work, a time-saving and conservative approach - temperature-switching approach (TSA) - to simulate the ELDRS of bipolar devices is presented. Good agreement is observed between the predictive curve obtained with the TSA and the LDR data, and TSA provides us with a new insight into the test technique for ELDRS. Additionally, the mechanisms of TSA are analyzed in this paper.
Vives-Vergara, Alejandra; González-López, Francisca; Solar, Orielle; Bernales-Baksai, Pamela; González, María José; Benach, Joan
2017-04-20
The purpose of this study is to perform a psychometric analysis (acceptability, reliability and factor structure) of the Chilean version of the new Employment Precariousness Scale (EPRES). The data is drawn from a sample of 4,248 private salaried workers with a formal contract from the first Chilean Employment Conditions, Work, Health and Quality of Life (ENETS) survey, applied to a nationally representative sample of the Chilean workforce in 2010. Item and scale-level statistics were performed to assess scaling properties, acceptability and reliability. The six-dimensional factor structure was examined with confirmatory factor analysis. The scale exhibited high acceptability (roughly 80%) and reliability (Cronbach's alpha 0.83) and the factor structure was confirmed. One subscale (rights) demonstrated poorer metric properties without compromising the overall scale. The Chilean version of the Employment Precariousness Scale (EPRES-Ch) demonstrated good metric properties, pointing to its suitability for use in epidemiologic and public health research.
NASA Astrophysics Data System (ADS)
Tao, Ye; Ding, Wentao; Wang, Zhongqiang; Xu, Haiyang; Zhao, Xiaoning; Li, Xuhong; Liu, Weizhen; Ma, Jiangang; Liu, Yichun
2018-05-01
In this work, we demonstrated an effective method to improve the switching reliability of HfOx based RRAM device by inserting mountain-like surface-graphited carbon (MSGC) layer. The MSGC layer was fabricated through thermal annealing of amorphous carbon (a-C) film with high sp2 proportion (49.7%) under 500 °C on Pt substrate, whose characteristics were validated by XPS and Raman spectrums. The local electric-field (LEF) was enhanced around the nanoscale tips of MSGC layer due to large surface curvature, which leads to simplified CFs and localization of resistive switching region. It takes responsibility to the reduction of high/low resistance states (HRS/LRS) fluctuation from 173.8%/64.9% to 23.6%/6.5%, respectively. In addition, the resulting RRAM devices exhibited fast switching speed (<65 ns), good retention (>104 s at 85 °C) and low cycling degradation. This method could be promising to develop reliable and repeatable high-performance RRAM for practical applications.
Reliability of two social cognition tests: The combined stories test and the social knowledge test.
Thibaudeau, Élisabeth; Cellard, Caroline; Legendre, Maxime; Villeneuve, Karèle; Achim, Amélie M
2018-04-01
Deficits in social cognition are common in psychiatric disorders. Validated social cognition measures with good psychometric properties are necessary to assess and target social cognitive deficits. Two recent social cognition tests, the Combined Stories Test (COST) and the Social Knowledge Test (SKT), respectively assess theory of mind and social knowledge. Previous studies have shown good psychometric properties for these tests, but the test-retest reliability has never been documented. The aim of this study was to evaluate the test-retest reliability and the inter-rater reliability of the COST and the SKT. The COST and the SKT were administered twice to a group of forty-two healthy adults, with a delay of approximately four weeks between the assessments. Excellent test-retest reliability was observed for the COST, and a good test-retest reliability was observed for the SKT. There was no evidence of practice effect. Furthermore, an excellent inter-rater reliability was observed for both tests. This study shows a good reliability of the COST and the SKT that adds to the good validity previously reported for these two tests. These good psychometrics properties thus support that the COST and the SKT are adequate measures for the assessment of social cognition. Copyright © 2018. Published by Elsevier B.V.
Kumar, Santhosh; Kroon, Jeroen; Lalloo, Ratilal; Johnson, Newell W
2016-03-01
Parental-Caregiver Perception Questionnaire (P-CPQ) and Family Impact Scale (FIS) are commonly used measures to evaluate the parent's perception of the impact of children's oral health on quality of life and family respectively. Recently, shorter forms of P-CPQ and FIS have been developed. No study has sought to validate these short forms in other languages and cultures. This study aimed to evaluate the validity and reliability of FIS, 8 and 16-item P-CPQ in a Telugu speaking population of India. For this cross-sectional study, a multi-stage random sampling technique was used to recruit 11-13 year-old schoolchildren of Medak district, Telangana, India and their parents (n = 1342). Parents were approached with questionnaires through their children who underwent clinical examinations for dental caries, fluorosis and malocclusion. The translated versions underwent pilot testing (n = 40), test-retest reliability was also assessed (n = 161). The overall summary scale and subscales of the short forms of P-CPQ and FIS failed to discriminate between the categories of dental caries severity. Also, malocclusion status was not related to the domain or overall scores of both the short forms of P-CPQ. There were significant differences in subscale and overall scores of 16 and 8-item P-CPQ and FIS between the fluorosis categories. Both 16 and 8-item P-CPQ summary scales were significantly related to parent's global rating of oral health (16-item, r = 0.30, p < 0.01; 8-item, r = 0.28, p < 0.01) and overall wellbeing (16-item, r = 0.22, p < 0.01; 8-item, r = 0.22, p < 0.01), thereby exhibiting good construct validity. However, the correlation of emotional and social wellbeing scales of short forms of P-CPQ and FIS with global ratings was of low strength. Cronbach's alphas for FIS, 16-items and 8-items P-CPQ scales were 0.78, 0.83 and 0.71 respectively, while the Intra-Class Correlation coefficients were 0.752, 0.812 and 0.816 respectively. Cronbach's alphas for most of the subscales of short forms of P-CPQ were less than 0.7. The overall scales of 16 and 8-items P-CPQ scales demonstrated good construct validity while the construct validity of FIS was questionable. Discriminant validity of all the three instruments was good only in relation to fluorosis. Overall scales of all three short forms exhibited acceptable internal consistency and reliability on repeated administrations.
Kumar, Santhosh; Kroon, Jeroen; Lalloo, Ratilal; Johnson, Newell W
2016-01-01
Oral health related quality of life research among children in India is still nascent and no measures have been validated to date. Although CPQ11-14 has been previously used in studies from the Indian sub-continent, the instrument has never been tested for cross-cultural adaptability. This study aimed to assess the validity and reliability of CPQ11-14 in Telugu speaking Indian school children. Primary school children of Medak district, Telangana State, India, were recruited by a multi-stage probability sampling method. The translated questionnaire was initially pilot tested on a small subset of children (n = 40). Children with informed consent from parents (N = 1342) were then provided with questionnaires containing the Telugu translation of CPQ11-14, followed by a clinical examination conducted by a single examiner, using Basic WHO survey methods for dental caries, malocclusion, and Dean's Fluorosis index. Children (n = 161) in randomly chosen schools were re-administered the same questionnaire after a two week interval to test reliability of CPQ11-14 on repeated administrations. Internal consistency and test-retest reliability as determined by Cronbach's alpha and Intra-class correlation coefficient for overall CPQ11-14 scale were 0.925 and 0.923, respectively. CPQ11-14 discriminated between the categories of fluorosis and malocclusion while its discriminant validity with respect to dental caries was limited. CPQ11-14 also demonstrated good construct validity with both overall CPQ11-14 and its subscales having significant positive correlation with global ratings of oral health and overall wellbeing, even after adjusting for confounding variables. CPQ11-14 had a correlation of 0.405 with self-evaluated oral health and 0.407 with self-evaluated impact of oral health on overall wellbeing. In conclusion, Telugu translation of CPQ11-14 demonstrated good internal consistency and excellent reliability on repeated administrations after two weeks. It also exhibited good discriminant and construct validity.
Combined photoacoustic and magneto-acoustic imaging.
Qu, Min; Mallidi, Srivalleesha; Mehrmohammadi, Mohammad; Ma, Li Leo; Johnston, Keith P; Sokolov, Konstantin; Emelianov, Stanislav
2009-01-01
Ultrasound is a widely used modality with excellent spatial resolution, low cost, portability, reliability and safety. In clinical practice and in the biomedical field, molecular ultrasound-based imaging techniques are desired to visualize tissue pathologies, such as cancer. In this paper, we present an advanced imaging technique - combined photoacoustic and magneto-acoustic imaging - capable of visualizing the anatomical, functional and biomechanical properties of tissues or organs. The experiments to test the combined imaging technique were performed using dual, nanoparticle-based contrast agents that exhibit the desired optical and magnetic properties. The results of our study demonstrate the feasibility of the combined photoacoustic and magneto-acoustic imaging that takes the advantages of each imaging techniques and provides high sensitivity, reliable contrast and good penetrating depth. Therefore, the developed imaging technique can be used in wide range of biomedical and clinical application.
Makkar, Steve R; Williamson, Anna; D'Este, Catherine; Redman, Sally
2017-12-19
Few measures of research use in health policymaking are available, and the reliability of such measures has yet to be evaluated. A new measure called the Staff Assessment of Engagement with Evidence (SAGE) incorporates an interview that explores policymakers' research use within discrete policy documents and a scoring tool that quantifies the extent of policymakers' research use based on the interview transcript and analysis of the policy document itself. We aimed to conduct a preliminary investigation of the usability, sensitivity, and reliability of the scoring tool in measuring research use by policymakers. Nine experts in health policy research and two independent coders were recruited. Each expert used the scoring tool to rate a random selection of 20 interview transcripts, and each independent coder rated 60 transcripts. The distribution of scores among experts was examined, and then, interrater reliability was tested within and between the experts and independent coders. Average- and single-measure reliability coefficients were computed for each SAGE subscales. Experts' scores ranged from the limited to extensive scoring bracket for all subscales. Experts as a group also exhibited at least a fair level of interrater agreement across all subscales. Single-measure reliability was at least fair except for three subscales: Relevance Appraisal, Conceptual Use, and Instrumental Use. Average- and single-measure reliability among independent coders was good to excellent for all subscales. Finally, reliability between experts and independent coders was fair to excellent for all subscales. Among experts, the scoring tool was comprehensible, usable, and sensitive to discriminate between documents with varying degrees of research use. Secondly, the scoring tool yielded scores with good reliability among the independent coders. There was greater variability among experts, although as a group, the tool was fairly reliable. The alignment between experts' and independent coders' ratings indicates that the independent coders were scoring in a manner comparable to health policy research experts. If the present findings are replicated in a larger sample, end users (e.g. policy agency staff) could potentially be trained to use SAGE to reliably score research use within their agencies, which would provide a cost-effective and time-efficient approach to utilising this measure in practice.
NASA Astrophysics Data System (ADS)
Zhong, H.; Tan, Y.; Gao, Z.
2018-02-01
A 30-channel movable magnetic probe radial array measuring the poloidal magnetic field's time derivative B˙ θ has been developed and installed on the Sino-United Spherical Tokamak to investigate the magnetohydrodynamic (MHD) activities in ohmic discharges. The probe array consists of thirty identical commercial chip inductors mounted on a slim printed circuit board and shielded by a customized quartz tube of 14 mm in outer diameter. With the application of instrumentation amplifiers, the system exhibits a good signal to noise ratio and the measured vertical field spatial distribution agrees well with the simulation result. The measured spatial and temporal distribution of B˙ θ during the MHD activities exhibits a clear phase reversal layer, which is a direct proof of tearing mode and provides a reliable indication of the magnetic island chain position.
Peer assessment of aviation performance: inconsistent for good reasons.
Roth, Wolff-Michael; Mavin, Timothy J
2015-03-01
Research into expertise is relatively common in cognitive science concerning expertise existing across many domains. However, much less research has examined how experts within the same domain assess the performance of their peer experts. We report the results of a modified think-aloud study conducted with 18 pilots (6 first officers, 6 captains, and 6 flight examiners). Pairs of same-ranked pilots were asked to rate the performance of a captain flying in a critical pre-recorded simulator scenario. Findings reveal (a) considerable variance within performance categories, (b) differences in the process used as evidence in support of a performance rating, (c) different numbers and types of facts (cues) identified, and (d) differences in how specific performance events affect choice of performance category and gravity of performance assessment. Such variance is consistent with low inter-rater reliability. Because raters exhibited good, albeit imprecise, reasons and facts, a fuzzy mathematical model of performance rating was developed. The model provides good agreement with observed variations. Copyright © 2014 Cognitive Science Society, Inc.
Dervisevic, Muamer; Custiuc, Esma; Çevik, Emre; Şenel, Mehmet
2015-08-15
A novel nanocomposite host matrix for enzyme immobilization of xanthine oxidase was developed by incorporating MWCNT in poly(GMA-co-VFc) copolymer film. In the food industry fish is a product with a very low commercial life, and a high variability as well elevated level of xanthine is an important biomarker as a sign of spoilage. The fabricated process was characterized by scanning electron microscopy (SEM), and the electrochemical behaviors of the biosensor were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The prepared enzyme electrodes exhibited maximum response at pH 7.0 and 45°C +0.35 V and reached 95% of steady-state current in about ∼ 4 s and its sensitivity was 16 mAM(-1). Linear ranges (2-28 μM, 28-46 and 46-86 μM), analytical performance and a low detection limit 0.12 μM obtained from the xanthine biosensor gives reliable results in measuring xanthine concentration in the fish meat. All the results indicating that the resulting biosensor exhibited a good response to xanthine that was related to the addition of MWCNT in the polymeric mediator film which played an important role in the biosensor performance. In addition, the biosensor exhibited high good storage stability and satisfactory anti-interference ability. Copyright © 2015 Elsevier Ltd. All rights reserved.
Reliability and validity of aggressive driving measures in China.
Li, Fengzhi; Li, Changji; Long, Yunfang; Zhan, Chenglie; Hennessy, Dwight
2004-12-01
The present research was designed to examine the psychometric properties of Chinese versions of the Self Report Driver Behavior Aggression and Assertiveness subscales, the Driving Vengeance Questionnaire, and the Violent Driving Questionnaire. Study 1 found that the all scales demonstrated good internal consistency, with alphas ranging from .76 to .87 and that assertive driving was related to demerit points received over the past 12 months while driver aggression and violence were linked to collisions over the past 12 months. Study 2 found that the scales exhibited reasonable test-retest reliability, with correlations ranging from .82 to .89. Finally, Study 3 showed that each scale was predicted by other dangerous driving attitudes and behaviors, similar to the original versions. The consistency between the translated and original scales, the implications for use in a Chinese sample, and the uniformity of actions in the traffic environment across cultures are discussed.
Do people trust dentists? Development of the Dentist Trust Scale.
Armfield, J M; Ketting, M; Chrisopoulos, S; Baker, S R
2017-09-01
This study aimed to adapt a measure of trust in physicians to trust in dentists and to assess the reliability and validity of the measure. Questionnaire data were collected from a simple random sample of 596 Australian adults. The 11-item General Trust in Physicians Scale was modified to apply to dentists. The Dentist Trust Scale (DTS) had good internal consistency (α = 0.92) and exploratory factor analysis revealed a single-factor solution. Lower DTS scores were associated with less trust in the dentist last visited, having previously changed dentists due to unhappiness with the care received, currently having dental pain, usual visiting frequency, dental avoidance, and with past experiences of discomfort, gagging, fainting, embarrassment and personal problems with the dentist. The majority of people appear to exhibit trust in dentists. The DTS shows promising reliability and validity evidence. © 2017 Australian Dental Association.
Touyama, Akiko; Nakada, Shina; Higa, Osamu; Itoh, Shigeru
2017-01-01
Citrus junos Tanaka (yuzu) has a strong characteristic aroma and thus its juice is used in various Japanese foods. Herein, we evaluate the volatile compounds in yuzu juice to investigate whether underwater shockwave pretreatment affects its scent. A shockwave pretreatment at increased discharge and energy of 3.5 kV and 4.9 kJ, respectively, increased the content of aroma-active compounds. Moreover, the underwater shockwave pretreatment afforded an approximate tenfold increase in the scent intensity of yuzu juice cultivated in Rikuzentakata. The proposed treatment method exhibited reliable and good performance for the extraction of volatile and aroma-active compounds from the yuzu fruit. The broad applicability and high reliability of this technique for improving the scent of yuzu fruit juice were demonstrated, confirming its potential for application to a wide range of food extraction processes. PMID:28761874
Anota, Amélie; Mariet, Anne-Sophie; Maingon, Philippe; Joly, Florence; Bosset, Jean-François; Guizard, Anne-Valérie; Bittard, Hugues; Velten, Michel; Mercier, Mariette
2016-12-06
Health-related quality of life (HRQoL) has been positioned as one of the major endpoints in oncology. Thus, there is a need to validate cancer-site specific survey instruments. This study aimed to perform a transcultural adaptation of the 50-item Expanded Prostate cancer Index Composite (EPIC) questionnaire for HRQoL in prostate cancer patients and to validate the psychometric properties of the French-language version. The EPIC questionnaire measures urinary, bowel, sexual and hormonal domains. The first step, corresponding to transcultural adaptation of the original English version of the EPIC was performed according to the back translation technique. The second step, comprising the validation of the psychometric properties of the EPIC questionnaire, was performed in patients under treatment for localized prostate cancer (treatment group) and in patients cured of prostate cancer (cured group). The EORTC QLQ-C30 and QLQ-PR25 prostate cancer module were also completed by patients to assess criterion validity. Two assessments were performed, i.e., before and at the end of treatment for the Treatment group, to assess sensitivity to change; and at 2 weeks' interval in the Cured group to assess test-retest reliability. Psychometric properties were explored according to classical test theory. The first step showed overall good acceptability and understanding of the questionnaire. In the second step, 215 patients were included from January 2012 to June 2014: 125 in the Treatment group, and 90 in the Cured group. All domains exhibited good internal consistency, except the bowel domain (Cronbach's α = 0.61). No floor effect was observed. Test-retest reliability assessed in the cured group was acceptable, expect for bowel function (intraclass coefficient = 0.68). Criterion validity was good for each domain and subscale. Construct validity was not demonstrated for the hormonal and bowel domains. Sensitivity to change was exhibited for 5/8 subscales and 2/4 summary scores for patients who experienced toxicities during treatment. The French EPIC questionnaire seems to have adequate psychometric properties, comparable to those exhibited by the original English-language version, except for the construct validity, which was not available in original version.
Treeing phenomenon of thermoplastic polyethylene blends for recyclable cable insulation materials
NASA Astrophysics Data System (ADS)
Li, Lunzhi; Zhang, Kai; Zhong, Lisheng; Gao, Jinghui; Xu, Man; Chen, Guanghui; Fu, Mingli
2017-02-01
Owing to its good recyclability and low processing energy consumption, non-crosslinked polyethylene blends (e.g. LLDPE-HDPE blends) are considered as one of potential environmental-friendly substitutions for crosslinked polyethylene (XLPE) as cable insulation material. Although extensive work has been performed for measuring the basic dielectric properties, there is a lack of the investigations on the aging properties for such a material system, which hinders the evaluation of reliability and lifetime of the material for cable insulation. In this paper, we study the electric aging phenomenon of 0.7LLDPE-0.3HDPE blending material by investigating the treeing behavior, and its comparison with XLPE and LLDPE. Treeing tests show that the 0.7LLDPE-0.3HDPE blends have lower probability for treeing as well as smaller treeing dimensions. Further thermal analysis and microstructure study results suggest that the blends exhibit larger proportion of thick lamellae and higher crystallinity with homogeneously-distributed amorphous region, which is responsible for good anti-treeing performance. Our finding provides the evidence that the 0.7LLDPE-0.3HDPE blends exhibits better electric-aging-retardance properties than XLPE, which may result in a potential application for cable insulation.
Costa, Daryne L M G; Rinaldo, Daniel; Varanda, Eliana A; de Sousa, Juliana F; Nasser, Ana L M; Silva, Ana C Z; Baldoqui, Débora C; Vilegas, Wagner; dos Santos, Lourdes Campaner
2014-10-01
It is well known that phytotherapy has grown in popularity in recent years. Because a drug cannot be administered without ensuring its effectiveness and safety, the standardization and regulation of phytotherapeutic drugs are required by the global market and governmental authorities. This article describes a simple and reliable high-performance liquid chromatography-diode array detection analysis method for the simultaneous detection of myricetin-3-O-β-D-galactopyranoside, myricetin-3-O-α-L-arabinopyranoside, and myricetin-3-O-α-L-rhaminopyranoside present in the hydroethanolic extract (ethanol/H2O, 7:3, v/v) of Pouteria torta. The mutagenic activity of the extract was evaluated on Salmonella typhimurium and by an in vivo micronucleus test on the peripheral blood cells of Swiss mice. The linearity, sensitivity, selectivity, repeatability, accuracy, and precision of the assay were evaluated. The analytical curves were linear and exhibited good repeatability (with a deviation of less than 5%) and demonstrated good recovery (within the 83-107% range). The results demonstrate that the hydroethanolic extract exhibited a mutagenic activity in both assays, suggesting caution in the use of this plant in folk medicine.
Page, Andrew C; Hooke, Geoffrey R; Morrison, David L
2007-09-01
The psychometric properties of the Depression Anxiety Stress Scales (DASS; Lovibond & Lovibond, 1995a) were examined in depressed psychiatric hospital samples. Three studies administered the DASS and other symptom measures at admission and discharge to consecutive adult hospital patients with a primary diagnosis of depression. Study 3 aimed to address problems with the DASS by extending the response options. Study 1 found that the DASS had good reliability and validity, was moderately sensitive to change, but the Depression Scale exhibited a ceiling effect. In Study 2, confirmatory factor analysis supported a three-factor structure and the DASS continued to demonstrate good psychometric properties, but the ceiling effect was replicated. Study 3 found that by extending the response scale to include an additional option, the factor structure of the instrument as a whole was maintained, the sensitivity to treatment was increased, but the ceiling effect was only marginally reduced. The psychometric properties of the DASS were sound in clinically depressed samples, but the Depression Scale exhibited a ceiling effect that could not be resolved with minor changes to the scale. Suggestions for revisions of the DASS are made.
Costa, Daryne L.M.G.; Rinaldo, Daniel; Varanda, Eliana A.; de Sousa, Juliana F.; Nasser, Ana L.M.; Silva, Ana C.Z.; Baldoqui, Débora C.; Vilegas, Wagner
2014-01-01
Abstract It is well known that phytotherapy has grown in popularity in recent years. Because a drug cannot be administered without ensuring its effectiveness and safety, the standardization and regulation of phytotherapeutic drugs are required by the global market and governmental authorities. This article describes a simple and reliable high-performance liquid chromatography–diode array detection analysis method for the simultaneous detection of myricetin-3-O-β-D-galactopyranoside, myricetin-3-O-α-L-arabinopyranoside, and myricetin-3-O-α-L-rhaminopyranoside present in the hydroethanolic extract (ethanol/H2O, 7:3, v/v) of Pouteria torta. The mutagenic activity of the extract was evaluated on Salmonella typhimurium and by an in vivo micronucleus test on the peripheral blood cells of Swiss mice. The linearity, sensitivity, selectivity, repeatability, accuracy, and precision of the assay were evaluated. The analytical curves were linear and exhibited good repeatability (with a deviation of less than 5%) and demonstrated good recovery (within the 83–107% range). The results demonstrate that the hydroethanolic extract exhibited a mutagenic activity in both assays, suggesting caution in the use of this plant in folk medicine. PMID:25055245
Noorbakhsh, Simasadat; Shams, Jamal; Faghihimohamadi, Mohamadmahdi; Zahiroddin, Hanieh; Hallgren, Mats; Kallmen, Hakan
2018-01-30
Iran is a developing and Islamic country where the consumption of alcoholic beverages is banned. However, psychiatric disorders and alcohol use disorders are often co-occurring. We used the Alcohol Use Disorders Identification Test (AUDIT) to estimate the prevalence of alcohol use and examined the psychometric properties of the test among psychiatric outpatients in Teheran, Iran. AUDIT was completed by 846 consecutive (sequential) patients. Descriptive statistics, internal consistency (Cronbach alpha), confirmatory and exploratory factor analyses were used to analyze the prevalence of alcohol use, reliability and construct validity. 12% of men and 1% of women were hazardous alcohol consumers. Internal reliability of the Iranian version of AUDIT was excellent. Confirmatory factor analyses showed that the construct validity and the fit of previous factor structures (1, 2 and 3 factors) to data were not good and seemingly contradicted results from the explorative principal axis factoring, which showed that a 1-factor solution explained 77% of the co-variances. We could not reproduce the suggested factor structure of AUDIT, probably due to the skewed distribution of alcohol consumption. Only 19% of men and 3% of women scored above 0 on AUDIT. This could be explained by the fact that alcohol is illegal in Iran. In conclusion the AUDIT exhibited good internal reliability when used as a single scale. The prevalence estimates according to AUDIT were somewhat higher among psychiatric patients compared to what was reported by WHO regarding the general population.
Grandes, Gonzalo; Bully, Paola; Martinez, Catalina; Gagnon, Marie-Pierre
2017-11-10
Organizational readiness to change healthcare practice is a major determinant of successful implementation of evidence-based interventions. However, we lack of comprehensive, valid, and reliable instruments to measure it. We assessed the validity and reliability of the Spanish version of the Organizational Readiness for Knowledge Translation (OR4KT) questionnaire in the context of the implementation of the Prescribe Vida Saludable III project, which seeks to strengthen health promotion and chronic disease prevention in primary healthcare organizations of the Osakidetza (Basque Health Service, Spain). A cross-sectional study was conducted including 127 professionals from 20 primary care centers within Osakidetza. They filled in the OR4KT questionnaire twice in a 15- to 30-day period to test repeatability. In addition, we used the Survey of Organizational Attributes for Primary Care (SOAPC) and we documented the number of healthcare professionals who formally engaged in the Prescribe Vida Saludable III project within each participating center to assess concurrent validity. Cronbach's alpha for the overall OR4KT was .95, and the overall repeatability coefficient was 6.95%, both excellent results. Confirmatory factor analysis supported the underlying theoretical structure of 6 dimensions and 23 sub-dimensions. There were positive moderate-to-high internal correlations between these six dimensions, and there was evidence of good concurrent validity (correlation coefficient of .76 with SOAPC, and .80 with the proportion of professionals engaged by center). A score higher than 64 (out of 100) would be indicative of an organization with high level of readiness to implement the intervention (sensitivity = .75, specificity = 1). The Spanish version of the OR4KT exhibits very strong reliability and good validity, although it needs to be validated in a larger sample and in different implementation contexts.
Niméus, A; Hjalmarsson Ståhlfors, F; Sunnqvist, C; Stanley, B; Träskman-Bendz, L
2006-10-01
The Suicide Assessment Scale (SUAS) was constructed to be sensitive to change of suicidality. It was recently found to be predictive of suicide in a group of suicide attempters. The aim of the present study was to evaluate the reliability and validity of a modified interview version of SUAS with defined scores and also a new self-rating version (SUAS-S). The subjects consisted of former inpatients, 42 persons who had been admitted because of a suicide attempt about 12 years ago and 22 control patients. The subjects were rated according to the SUAS, the SUAS-S, as well as the Montgomery Asberg Depression Rating Scale (MADRS). The interrater reliability was found to be high. The SUAS correlated significantly with the MADRS, but the concordance was not consistent, which indicates that the SUAS measures something different from depression. The SUAS-S correlated significantly with the interview-rated SUAS, thus exhibiting good concurrent validity. In summary, both the modified interview version of SUAS and the SUAS-S seem to be valid, reliable and easily used suicide assessment instruments.
Development, scoring, and reliability of the Microscale Audit of Pedestrian Streetscapes (MAPS)
2013-01-01
Background Streetscape (microscale) features of the built environment can influence people’s perceptions of their neighborhoods’ suitability for physical activity. Many microscale audit tools have been developed, but few have published systematic scoring methods. We present the development, scoring, and reliability of the Microscale Audit of Pedestrian Streetscapes (MAPS) tool and its theoretically-based subscales. Methods MAPS was based on prior instruments and was developed to assess details of streetscapes considered relevant for physical activity. MAPS sections (route, segments, crossings, and cul-de-sacs) were scored by two independent raters for reliability analyses. There were 290 route pairs, 516 segment pairs, 319 crossing pairs, and 53 cul-de-sac pairs in the reliability sample. Individual inter-rater item reliability analyses were computed using Kappa, intra-class correlation coefficient (ICC), and percent agreement. A conceptual framework for subscale creation was developed using theory, expert consensus, and policy relevance. Items were grouped into subscales, and subscales were analyzed for inter-rater reliability at tiered levels of aggregation. Results There were 160 items included in the subscales (out of 201 items total). Of those included in the subscales, 80 items (50.0%) had good/excellent reliability, 41 items (25.6%) had moderate reliability, and 18 items (11.3%) had low reliability, with limited variability in the remaining 21 items (13.1%). Seventeen of the 20 route section subscales, valence (positive/negative) scores, and overall scores (85.0%) demonstrated good/excellent reliability and 3 demonstrated moderate reliability. Of the 16 segment subscales, valence scores, and overall scores, 12 (75.0%) demonstrated good/excellent reliability, three demonstrated moderate reliability, and one demonstrated poor reliability. Of the 8 crossing subscales, valence scores, and overall scores, 6 (75.0%) demonstrated good/excellent reliability, and 2 demonstrated moderate reliability. The cul-de-sac subscale demonstrated good/excellent reliability. Conclusions MAPS items and subscales predominantly demonstrated moderate to excellent reliability. The subscales and scoring system represent a theoretically based framework for using these complex microscale data and may be applicable to other similar instruments. PMID:23621947
Scale for positive aspects of caregiving experience: development, reliability, and factor structure.
Kate, N; Grover, S; Kulhara, P; Nehra, R
2012-06-01
OBJECTIVE. To develop an instrument (Scale for Positive Aspects of Caregiving Experience [SPACE]) that evaluates positive caregiving experience and assess its psychometric properties. METHODS. Available scales which assess some aspects of positive caregiving experience were reviewed and a 50-item questionnaire with a 5-point rating was constructed. In all, 203 primary caregivers of patients with severe mental disorders were asked to complete the questionnaire. Internal consistency, test-retest reliability, cross-language reliability, split-half reliability, and face validity were evaluated. Principal component factor analysis was run to assess the factorial validity of the scale. RESULTS. The scale developed as part of the study was found to have good internal consistency, test-retest reliability, cross-language reliability, split-half reliability, and face validity. Principal component factor analysis yielded a 4-factor structure, which also had good test-retest reliability and cross-language reliability. There was a strong correlation between the 4 factors obtained. CONCLUSION. The SPACE developed as part of this study has good psychometric properties.
Reliability and validity of a Chinese version of the Diagnostic Interview for Borderlines-Revised.
Wang, Lanlan; Yuan, Chenmei; Qiu, Jianying; Gunderson, John; Zhang, Min; Jiang, Kaida; Leung, Freedom; Zhong, Jie; Xiao, Zeping
2014-09-01
Borderline personality disorder (BPD) is the most studied of the axis II disorders. One of the most widely used diagnostic instruments is the Diagnostic Interview for Borderline Patients-Revised (DIB-R). The aim of this study was to test the reliability and validity of DIB-R for use in the Chinese culture. The reliability and validity of the DIB-R Chinese version were assessed in a sample of 236 outpatients with a probable BPD diagnosis. The Structured Clinical Interview for DSM-IV Personality Disorders (SCID-II) was used as a standard. Test-retest reliability was tested six months later with 20 patients, and inter-rater reliability was tested on 32 patients. The Chinese version of the DIB-R showed good internal global consistency (Cronbach's α of 0.916), good test-retest reliability (Pearson correlation of 0.704), good inter-rater reliability (intra-class correlation coefficient of 0.892 and kappa of 0.861). When compared with the DSM-IV diagnosis as measured by the SCID-II, the DIB-R showed relatively good sensitivity (0.768) and specificity (0.891) at the cutoff of 7, moderate diagnostic convergence (kappa of 0.631), as well as good discriminating validity. The Chinese version of the DIB-R has good psychometric properties, which renders it a valuable method for examining the presence, the severity, and component phenotypes of BPD in Chinese samples. © 2013 Wiley Publishing Asia Pty Ltd.
Wu, Jiayuan; Hu, Liren; Zhang, Gaohua; Liang, Qilian; Meng, Qiong; Wan, Chonghua
2016-08-01
This research was designed to develop a nasopharyngeal cancer (NPC) scale based on quality of life (QOL) instruments for cancer patients (QLICP-NA). This scale was developed by using a modular approach and was evaluated by classical test and generalizability theories. Programmed decision procedures and theories on instrument development were applied to create QLICP-NA V2.0. A total of 121 NPC inpatients were assessed using QLICP-NA V2.0 to measure their QOL data from hospital admission until discharge. Scale validity, reliability, and responsiveness were evaluated by correlation, factor, parallel, multi-trait scaling, and t test analyses, as well as by generalizability (G) and decision (D) studies of the generalizability theory. Results of multi-trait scaling, correlation, factor, and parallel analyses indicated that QLICP-NA V2.0 exhibited good construct validity. The significant difference of QOL between the treated and untreated NPC patients indicated a good clinical validity of the questionnaire. The internal consistency (α) and test-retest reliability coefficients (intra-class correlations) of each domain, as well as the overall scale, were all >0.70. Ceiling effects were not found in all domains and most facets, except for common side effects (24.8 %) in the domain of common symptoms and side effects, tumor early symptoms (27.3 %) and therapeutic side effects (23.2 %) in specific domain, whereas floor effects did not exist in each domain/facet. The overall changes in the physical and social domains were significantly different between pre- and post-treatments with a moderate effective size (standard response mean) ranging from 0.21 to 0.27 (p < 0.05), but these changes were not obvious in the other domains, as well as in the overall scale. Scale reliability was further confirmed by G coefficients and index of dependability, with more exact variance components based on generalizability theory. QLICP-NA V2.0 exhibited reasonable degrees of validity, reliability, and responsiveness. However, this scale must be further improved before it can be used as a practical instrument to evaluate the QOL of NPC patients in China.
On the reliability of seasonal climate forecasts.
Weisheimer, A; Palmer, T N
2014-07-06
Seasonal climate forecasts are being used increasingly across a range of application sectors. A recent UK governmental report asked: how good are seasonal forecasts on a scale of 1-5 (where 5 is very good), and how good can we expect them to be in 30 years time? Seasonal forecasts are made from ensembles of integrations of numerical models of climate. We argue that 'goodness' should be assessed first and foremost in terms of the probabilistic reliability of these ensemble-based forecasts; reliable inputs are essential for any forecast-based decision-making. We propose that a '5' should be reserved for systems that are not only reliable overall, but where, in particular, small ensemble spread is a reliable indicator of low ensemble forecast error. We study the reliability of regional temperature and precipitation forecasts of the current operational seasonal forecast system of the European Centre for Medium-Range Weather Forecasts, universally regarded as one of the world-leading operational institutes producing seasonal climate forecasts. A wide range of 'goodness' rankings, depending on region and variable (with summer forecasts of rainfall over Northern Europe performing exceptionally poorly) is found. Finally, we discuss the prospects of reaching '5' across all regions and variables in 30 years time.
Braverman, Julia; Dunn, Rita
2018-01-01
Mental synthesis is the conscious purposeful process of synthesizing novel mental images from objects stored in memory. Mental synthesis ability is essential for understanding complex syntax, spatial prepositions, and verb tenses. In typical children, the timeline of mental synthesis acquisition is highly correlated with an increasing vocabulary. Children with Autism Spectrum Disorder (ASD), on the other hand, may learn hundreds of words but never acquire mental synthesis. In these individuals, tests assessing vocabulary comprehension may fail to demonstrate the profound deficit in mental synthesis. We developed a parent-reported Mental Synthesis Evaluation Checklist (MSEC) designed to assess mental synthesis acquisition in ASD children. The psychometric quality of MSEC was tested with 3715 parents of ASD children. Internal reliability of the 20-item MSEC was good (Cronbach’s alpha >0.9). MSEC exhibited adequate test–retest reliability; good construct validity, supported by a positive correlation with the Autism Treatment Evaluation Checklist (ATEC) Communication subscale; and good known group validity reflected by the difference in MSEC scores for children of different ASD severity levels. The MSEC questionnaire is copyright-free and can be used by researchers as a complimentary subscale for the ATEC evaluation. We hope that the addition of MSEC will make the combined assessment more sensitive to small steps in a child’s development. As MSEC does not rely on productive language, it may be an especially useful tool for assessing the development of nonverbal and minimally verbal children. PMID:29783788
The reliability of the Glasgow Coma Scale: a systematic review.
Reith, Florence C M; Van den Brande, Ruben; Synnot, Anneliese; Gruen, Russell; Maas, Andrew I R
2016-01-01
The Glasgow Coma Scale (GCS) provides a structured method for assessment of the level of consciousness. Its derived sum score is applied in research and adopted in intensive care unit scoring systems. Controversy exists on the reliability of the GCS. The aim of this systematic review was to summarize evidence on the reliability of the GCS. A literature search was undertaken in MEDLINE, EMBASE and CINAHL. Observational studies that assessed the reliability of the GCS, expressed by a statistical measure, were included. Methodological quality was evaluated with the consensus-based standards for the selection of health measurement instruments checklist and its influence on results considered. Reliability estimates were synthesized narratively. We identified 52 relevant studies that showed significant heterogeneity in the type of reliability estimates used, patients studied, setting and characteristics of observers. Methodological quality was good (n = 7), fair (n = 18) or poor (n = 27). In good quality studies, kappa values were ≥0.6 in 85%, and all intraclass correlation coefficients indicated excellent reliability. Poor quality studies showed lower reliability estimates. Reliability for the GCS components was higher than for the sum score. Factors that may influence reliability include education and training, the level of consciousness and type of stimuli used. Only 13% of studies were of good quality and inconsistency in reported reliability estimates was found. Although the reliability was adequate in good quality studies, further improvement is desirable. From a methodological perspective, the quality of reliability studies needs to be improved. From a clinical perspective, a renewed focus on training/education and standardization of assessment is required.
Kim, Jae-Woo; Jeong, Jin-Woo; Kang, Jun-Tae; Choi, Sungyoul; Ahn, Seungjoon; Song, Yoon-Ho
2014-02-14
Highly reliable field electron emitters were developed using a formulation for reproducible damage-free carbon nanotube (CNT) composite pastes with optimal inorganic fillers and a ball-milling method. We carefully controlled the ball-milling sequence and time to avoid any damage to the CNTs, which incorporated fillers that were fully dispersed as paste constituents. The field electron emitters fabricated by printing the CNT pastes were found to exhibit almost perfect adhesion of the CNT emitters to the cathode, along with good uniformity and reproducibility. A high field enhancement factor of around 10,000 was achieved from the CNT field emitters developed. By selecting nano-sized metal alloys and oxides and using the same formulation sequence, we also developed reliable field emitters that could survive high-temperature post processing. These field emitters had high durability to post vacuum annealing at 950 °C, guaranteeing survival of the brazing process used in the sealing of field emission x-ray tubes. We evaluated the field emitters in a triode configuration in the harsh environment of a tiny vacuum-sealed vessel and observed very reliable operation for 30 h at a high current density of 350 mA cm(-2). The CNT pastes and related field emitters that were developed could be usefully applied in reliable field emission devices.
NASA Astrophysics Data System (ADS)
Kim, Jae-Woo; Jeong, Jin-Woo; Kang, Jun-Tae; Choi, Sungyoul; Ahn, Seungjoon; Song, Yoon-Ho
2014-02-01
Highly reliable field electron emitters were developed using a formulation for reproducible damage-free carbon nanotube (CNT) composite pastes with optimal inorganic fillers and a ball-milling method. We carefully controlled the ball-milling sequence and time to avoid any damage to the CNTs, which incorporated fillers that were fully dispersed as paste constituents. The field electron emitters fabricated by printing the CNT pastes were found to exhibit almost perfect adhesion of the CNT emitters to the cathode, along with good uniformity and reproducibility. A high field enhancement factor of around 10 000 was achieved from the CNT field emitters developed. By selecting nano-sized metal alloys and oxides and using the same formulation sequence, we also developed reliable field emitters that could survive high-temperature post processing. These field emitters had high durability to post vacuum annealing at 950 °C, guaranteeing survival of the brazing process used in the sealing of field emission x-ray tubes. We evaluated the field emitters in a triode configuration in the harsh environment of a tiny vacuum-sealed vessel and observed very reliable operation for 30 h at a high current density of 350 mA cm-2. The CNT pastes and related field emitters that were developed could be usefully applied in reliable field emission devices.
Xiao, Yuan-mei; Wang, Zhi-ming; Wang, Mian-zhen; Lan, Ya-jia
2005-06-01
To test the reliability and validity of two mental workload assessment scales, i.e. subjective workload assessment technique (SWAT) and NASA task load index (NASA-TLX). One thousand two hundred and sixty-eight mental workers were sampled from various kinds of occupations, such as scientific research, education, administration and medicine, etc, with randomized cluster sampling. The re-test reliability, split-half reliability, Cronbach's alpha coefficient and correlation coefficients between item score and total score were adopted to test the reliability. The test of validity included structure validity. The re-test reliability coefficients of these two scales and their items were ranged from 0.516 to 0.753 (P < 0.01), indicating the two scales had good re-test reliability; the split-half reliability of SWAT was 0.645, and its Cronbach's alpha coefficient was more than 0.80, all the correlation coefficients between its items score and total score were more than 0.70; as for NASA-TLX, both the split-half reliability and Cronbach's alpha coefficient were more than 0.80, the correlation coefficients between its items score and total score were all more than 0.60 (P < 0.01) except the item of performance. Both scales had good inner consistency. The Pearson correlation coefficient between the two scales was 0.492 (P < 0.01), implying the results of the two scales had good consistency. Factor analysis showed that the two scales had good structure validity. Both SWAT and NASA-TLX have good reliability and validity and may be used as a valid tool to assess mental workload in China after being revised properly.
Løvstad, Marianne; Frøslie, Kathrine F; Giacino, Joseph T; Skandsen, Toril; Anke, Audny; Schanke, Anne-Kristine
2010-01-01
To confirm the reliability and diagnostic validity of the JFK Coma Recovery Scale-Revised (CRS-R) across raters with varying levels of experience. Thirty-one patients with disorders of consciousness were recruited from 6 Norwegian hospitals. CRS-R and the Disability Rating Scale. Reliability measures were good for the CRS-R total scores and moderate to good for its subscales. Diagnostic agreement among examiners was good. Raters' experience with the CRS-R favorably influenced reliability. Sensitivity and specificity analyses demonstrated better detection of patients in minimally conscious state on the CRS-R relative to the Disability Rating Scale. The CRS-R is a reliable tool for diagnosing vegetative state and minimally conscious state. Raters' level of experience influences the reliability of the CRS-R scores.
NASA Astrophysics Data System (ADS)
Huang, Cheng-Lin; Lai, Chih-Huang; Tsai, Po-Hao; Kuo, Yu-Lin; Lin, Jing-Cheng; Lee, Chiapyng
2014-05-01
In this study, we investigated the thermal stability, wettability, adhesion and reliability of (Ti,Zr)N x films used as the diffusion barrier between Cu and Si. (Ti,Zr)N x films were prepared by DC reactive magnetron sputtering from a Ti-5 at. % Zr alloy target in N2/Ar gas mixtures. A minimum film resistivity of 59.3 µω cm was obtained at an N2/Ar flow ratio of 2.75, which corresponds to the near stoichiometric composition (N/(Ti,Zr) ratio ˜0.95). The sheet resistance of Cu/(Ti,Zr)N0.95/Si was not significantly increased until annealing above 750°C, indicating good thermal stability. On the other hand, the adhesion energy between Cu and the (Ti,Zr)Nx film was reduced as the N/Ti ratio was increased. To obtain reliable performance on stress-induced-voiding (SIV) and electromigration (EM) tests, we proposed to use (Ti,Zr)/(Ti,Zr)N x /(Ti,Zr) tri-layers. We suggest that the interfacial adhesion between barrier and Cu plays an important role in reliability. The proposed tri-layer structure may be a promising candidate for a barrier, as it exhibits excellent reliability without increasing resistance.
Developing and testing the patient-centred innovation questionnaire for hospital nurses.
Huang, Ching-Yuan; Weng, Rhay-Hung; Wu, Tsung-Chin; Lin, Tzu-En; Hsu, Ching-Tai; Hung, Chiu-Hsia; Tsai, Yu-Chen
2018-03-01
Develop the patient-centred innovation questionnaire for hospital nurses and establish its validity and reliability. Patient-centred care has been adopted by health care managers in their efforts to improve health care quality. It is regarded as a core concept for developing innovation. A cross-sectional study was employed to collect data from hospital nurses in Taiwan. This study was divided into two stages: pilot study and main study. In the main study, 596 valid responses were collected. This study adopted reliability analysis, exploratory factor analysis, confirmatory factor analysis and selected nurse innovation scale as a criterion to test criterion-related validity. Five-dimension patient-centred innovation questionnaire was proposed: access and practicability, co-ordination and communication, sharing power and responsibility, care continuity, family and person focus. Each dimension demonstrated a reliability of 0.89-0.98. All dimensions had acceptable convergent and discriminate validity. The patient-centred innovation questionnaire and nurse innovation scale exhibited a significantly positive correlation. Patient-centred innovation questionnaire not only had a good theoretical basis but also had sufficient reliability and construct validity, and criterion-related validity. Patient-centred innovation questionnaire could give a measure for evaluating the implementation of patient-centred care and could be used as a management tool during the process of nurse innovation. © 2017 John Wiley & Sons Ltd.
Dunleavy, Kim; Neil, Joseph; Tallon, Allison; Adamo, Diane E
2015-09-01
The cervical range of motion device (CROM) has been shown to provide reliable forward head position (FHP) measurement when the upper cervical angle (UCA) is controlled. However, measurement without UCA standardization is reflective of habitual patterns. Criterion validity has not been reported. The purposes of this study were to establish: (1) criterion validity of CROM FHP and UCA compared to Optotrak data, (2) relative reliability and minimal detectable change (MDC95) in patients with and without cervical pain, and (3) to compare UCA and FHP in patients with and without pain in habitual postures. (1) Within-subjects single session concurrent criterion validity design. Simultaneous CROM and OP measurement was conducted in habitual sitting posture in 16 healthy young adults. (2) Reliability and MDC95 of UCA and FHP were calculated from three trials. (3) Values for adults over 35 years with cervical pain and age-matched healthy controls were compared. (1) Forward head position distances were moderately correlated and UCA angles were highly correlated. The mean (standard deviation) differences can be expected to vary between 1·48 cm (1·74) for FHP and -1·7 (2·46)° for UCA. (2) Reliability for CROM FHP measurements were good to excellent (no pain) and moderate (pain). Cervical range of motion FHP MDC95 was moderately low (no pain), and moderate (pain). Reliability for CROM UCA measurements was excellent and MDC95 low for both groups. There was no difference in FHP distances between the pain and no pain groups, UCA was significantly more extended in the pain group (P<0·05). Cervical range of motion FHP measurements were only moderately correlated with Optotrak data, and limits of agreement (LOA) and MDC95 were relatively large. There was also no difference in CROM FHP distance between older symptomatic and asymptomatic individuals. Cervical range of motion FHP measurement is therefore not recommended as a clinical outcome measure. Cervical range of motion UCA measurements showed good criterion validity, excellent test-retest reliability, and achievable MDC95 in asymptomatic and symptomatic participants. Differences of more than 6° are required to exceed error. Cervical range of motion UCA shows promise as a useful reliable and valid measurement, particularly as patients with cervical pain exhibited significantly more extended angles.
Neil, Joseph; Tallon, Allison; Adamo, Diane E.
2015-01-01
Objectives The cervical range of motion device (CROM) has been shown to provide reliable forward head position (FHP) measurement when the upper cervical angle (UCA) is controlled. However, measurement without UCA standardization is reflective of habitual patterns. Criterion validity has not been reported. The purposes of this study were to establish: (1) criterion validity of CROM FHP and UCA compared to Optotrak data, (2) relative reliability and minimal detectable change (MDC95) in patients with and without cervical pain, and (3) to compare UCA and FHP in patients with and without pain in habitual postures. Methods (1) Within-subjects single session concurrent criterion validity design. Simultaneous CROM and OP measurement was conducted in habitual sitting posture in 16 healthy young adults. (2) Reliability and MDC95 of UCA and FHP were calculated from three trials. (3) Values for adults over 35 years with cervical pain and age-matched healthy controls were compared. Results (1) Forward head position distances were moderately correlated and UCA angles were highly correlated. The mean (standard deviation) differences can be expected to vary between 1·48 cm (1·74) for FHP and −1·7 (2·46)° for UCA. (2) Reliability for CROM FHP measurements were good to excellent (no pain) and moderate (pain). Cervical range of motion FHP MDC95 was moderately low (no pain), and moderate (pain). Reliability for CROM UCA measurements was excellent and MDC95 low for both groups. There was no difference in FHP distances between the pain and no pain groups, UCA was significantly more extended in the pain group (P<0·05). Discussion Cervical range of motion FHP measurements were only moderately correlated with Optotrak data, and limits of agreement (LOA) and MDC95 were relatively large. There was also no difference in CROM FHP distance between older symptomatic and asymptomatic individuals. Cervical range of motion FHP measurement is therefore not recommended as a clinical outcome measure. Cervical range of motion UCA measurements showed good criterion validity, excellent test–retest reliability, and achievable MDC95 in asymptomatic and symptomatic participants. Differences of more than 6° are required to exceed error. Cervical range of motion UCA shows promise as a useful reliable and valid measurement, particularly as patients with cervical pain exhibited significantly more extended angles. PMID:26917936
Sonderer, Patrizia; Akhbari Ziegler, Schirin; Gressbach Oertle, Barbara; Meichtry, André; Hadders-Algra, Mijna
2017-07-01
Pediatric physical therapy (PPT) is characterized by heterogeneity. This blurs the evaluation of effective components of PPT. The Groningen Observation Protocol (GOP) was developed to quantify contents of PPT. This study assesses the reliability and completeness of the GOP. Sixty infant PPT sessions were video-taped. Two random samples of 10 videos were used to determine interrater and intrarater reliability using interclass correlation coefficients (ICCs) with 95% confidence intervals. Completeness of GOP 2.0 was based on 60 videos. Interrater reliability of quantifying PPT actions was excellent (ICC, 0.75-1.0) in 71% and sufficient to good (ICC, 0.4-0.74) in 24% of PPT actions. Intrarater reliability was excellent in 94% and sufficient to good in 6% of PPT actions. Completeness was good for greater than 90% of PPT actions. GOP 2.0 has good reliability and completeness. After appropriate training, it is a useful tool to quantify PPT for children with developmental disorders.
Development and validation of a questionnaire to evaluate infection control in oral radiology.
da Costa, Eliana D; Pinelli, Camila; da Silva Tagliaferro, Elaine P; Corrente, José E; Ambrosano, Glaucia M B
2017-04-01
To create and validate a questionnaire to evaluate infection control in oral radiology. The questionnaire was developed after review of the literature, which included published articles and the biosafety protocols available from healthcare agencies. The initial version of the questionnaire was composed of 14 multiple choice questions and was divided into 3 domains on handwashing, disinfection/protection of surfaces and disinfectant used. Content validity was assessed by two expert committees, which reviewed the content and scope of the questionnaire and the relevance of each item, respectively. Reliability was evaluated using test-retest and internal consistency methods with 115 undergraduate dentistry students. Construct validity was assessed using the known-groups technique and factor analysis. The known-groups technique involved 641 undergraduate dentistry students, 20 PhD students and 15 oral radiology professors. In the factor analysis, 3 radiology technicians also participated in addition to the 641 undergraduates, 20 PhD students and 15 oral radiology professors. The content validity results were found to be satisfactory to excellent for the ordinal variables (intraclass correlation coefficient = 0.722-1.000) and good to great for the yes/no questions (kappa = 0.662-0.913) in terms of reliability and good internal consistency (Cronbach's alpha = 0.88). After a factor analysis, some questions were excluded, and the questions were grouped into new domains. Significant differences were observed between answers from different groups. The final version of the questionnaire was composed of nine domains. The questionnaire created was found to exhibit good psychometric properties for assessing infection control in oral radiology.
Terslev, Lene; Naredo, Esperanza; Aegerter, Philippe; Wakefield, Richard J; Backhaus, Marina; Balint, Peter; Bruyn, George A W; Iagnocco, Annamaria; Jousse-Joulin, Sandrine; Schmidt, Wolfgang A; Szkudlarek, Marcin; Conaghan, Philip G; Filippucci, Emilio
2017-01-01
Objectives To test the reliability of new ultrasound (US) definitions and quantification of synovial hypertrophy (SH) and power Doppler (PD) signal, separately and in combination, in a range of joints in patients with rheumatoid arthritis (RA) using the European League Against Rheumatisms–Outcomes Measures in Rheumatology (EULAR-OMERACT) combined score for PD and SH. Methods A stepwise approach was used: (1) scoring static images of metacarpophalangeal (MCP) joints in a web-based exercise and subsequently when scanning patients; (2) scoring static images of wrist, proximal interphalangeal joints, knee and metatarsophalangeal joints in a web-based exercise and subsequently when scanning patients using different acquisitions (standardised vs usual practice). For reliability, kappa coefficients (κ) were used. Results Scoring MCP joints in static images showed substantial intraobserver variability but good to excellent interobserver reliability. In patients, intraobserver reliability was the same for the two acquisition methods. Interobserver reliability for SH (κ=0.87) and PD (κ=0.79) and the EULAR-OMERACT combined score (κ=0.86) were better when using a ‘standardised’ scan. For the other joints, the intraobserver reliability was excellent in static images for all scores (κ=0.8–0.97) and the interobserver reliability marginally lower. When using standardised scanning in patients, the intraobserver was good (κ=0.64 for SH and the EULAR-OMERACT combined score, 0.66 for PD) and the interobserver reliability was also good especially for PD (κ range=0.41–0.92). Conclusion The EULAR-OMERACT score demonstrated moderate-good reliability in MCP joints using a standardised scan and is equally applicable in non-MCP joints. This scoring system should underpin improved reliability and consequently the responsiveness of US in RA clinical trials. PMID:28948984
Kuraya, Eisuke; Nakada, Shina; Touyama, Akiko; Itoh, Shigeru
2017-02-01
Citrus junos Tanaka (yuzu) has a strong characteristic aroma, and hence, yuzu juice is used in a number of Japanese foods. We herein evaluated the functional compounds of yuzu juice to investigate whether underwater shockwave pretreatment affects its functionality. Employing the shockwave pretreatment at an increased discharge and energy of 3.5kV and 4.9kJ, respectively, resulted in an increase in the flavanone glycoside content and oxygen radical absorbance capacity (ORAC). The ORAC value of yuzu juice cultivated in Rikuzentakata increased approximately 1.7 times upon underwater shockwave pretreatment. The treatment method proposed herein exhibited reliable and good performance for the extraction of functional and antioxidant chemicals in yuzu fruits, and was comparable with traditional squeezing methods. The high applicability and reliability of this technique for improving the antioxidant functionality of yuzu fruit juice was demonstrated, confirming the potential for application to a wide range of food extraction processes. Copyright © 2016 Elsevier Ltd. All rights reserved.
Lohrer, Heinz; Nauck, Tanja; Korakakis, Vasileios; Malliaropoulos, Nikos
2016-10-24
The FASH (Functional Assessment Scale for Acute Hamstring Injuries) questionnaire has been recently developed as a disease-specific self-administered questionnaire for use in Greek, English, and German languages. Its psychometric qualities (validity and reliability) were tested only in Greek-speaking patients mainly representing track and field athletes. As hamstring injuries represent the most common football injury, we tested the validity and reliability of the FASH-G (G = German version) questionnaire in German-speaking footballers suffering from acute hamstring injuries. The FASH-G questionnaire was tested for reliability and validity, in 16 footballers with hamstring injuries (patients' group), 77 asymptomatic footballers (healthy group), and 19 field hockey players (at-risk group). Known-group validity was tested by comparing the total FASH-G scores of the injured and non-injured groups. Reliability of the FASH-G questionnaire was analysed in 18 asymptomatic footballers using the intra-class coefficient. Known-group validity was demonstrated by significant differences between injured and non-injured participants (p < 0.001). The FASH-G exhibited very good test-retest reliability (intra-class correlation coefficient = 0.982, p < 0.001). Internal consistency was excellent (α = 0.938). Compared with the results presented in the original publication, no statistical differences were found between healthy athletes (p = 0.257), but patients' groups and at-risk groups presented scoring differences (p = 0.040 and <0.001, respectively). The FASH-G is a valid and reliable instrument to assess and determine the severity of hamstring injuries in German footballers.
Y-balance test: a reliability study involving multiple raters.
Shaffer, Scott W; Teyhen, Deydre S; Lorenson, Chelsea L; Warren, Rick L; Koreerat, Christina M; Straseske, Crystal A; Childs, John D
2013-11-01
The Y-balance test (YBT) is one of the few field expedient tests that have shown predictive validity for injury risk in an athletic population. However, analysis of the YBT in a heterogeneous population of active adults (e.g., military, specific occupations) involving multiple raters with limited experience in a mass screening setting is lacking. The primary purpose of this study was to determine interrater test-retest reliability of the YBT in a military setting using multiple raters. Sixty-four service members (53 males, 11 females) actively conducting military training volunteered to participate. Interrater test-retest reliability of the maximal reach had intraclass correlation coefficients (2,1) of 0.80 to 0.85 with a standard error of measurement ranging from 3.1 to 4.2 cm for the 3 reach directions (anterior, posteromedial, and posterolateral). Interrater test-retest reliability of the average reach of 3 trails had an intraclass correlation coefficients (2,3) range of 0.85 to 0.93 with an associated standard error of measurement ranging from 2.0 to 3.5cm. The YBT showed good interrater test-retest reliability with an acceptable level of measurement error among multiple raters screening active duty service members. In addition, 31.3% (n = 20 of 64) of participants exhibited an anterior reach asymmetry of >4cm, suggesting impaired balance symmetry and potentially increased risk for injury. Reprint & Copyright © 2013 Association of Military Surgeons of the U.S.
Thomas C. Brown; David Kingsley; George L. Peterson; Nicholas E. Flores; Andrea Clarke; Andrej Birjulin
2008-01-01
We examined the reliability of a large set of paired comparison value judgments involving public goods, private goods, and sums of money. As respondents progressed through a random sequence of paired choices they were each given, their response time decreased and they became more consistent, apparently fine-tuning their responses, suggesting that respondents tend to...
The Pareidolia Test: A Simple Neuropsychological Test Measuring Visual Hallucination-Like Illusions.
Mamiya, Yasuyuki; Nishio, Yoshiyuki; Watanabe, Hiroyuki; Yokoi, Kayoko; Uchiyama, Makoto; Baba, Toru; Iizuka, Osamu; Kanno, Shigenori; Kamimura, Naoto; Kazui, Hiroaki; Hashimoto, Mamoru; Ikeda, Manabu; Takeshita, Chieko; Shimomura, Tatsuo; Mori, Etsuro
2016-01-01
Visual hallucinations are a core clinical feature of dementia with Lewy bodies (DLB), and this symptom is important in the differential diagnosis and prediction of treatment response. The pareidolia test is a tool that evokes visual hallucination-like illusions, and these illusions may be a surrogate marker of visual hallucinations in DLB. We created a simplified version of the pareidolia test and examined its validity and reliability to establish the clinical utility of this test. The pareidolia test was administered to 52 patients with DLB, 52 patients with Alzheimer's disease (AD) and 20 healthy controls (HCs). We assessed the test-retest/inter-rater reliability using the intra-class correlation coefficient (ICC) and the concurrent validity using the Neuropsychiatric Inventory (NPI) hallucinations score as a reference. A receiver operating characteristic (ROC) analysis was used to evaluate the sensitivity and specificity of the pareidolia test to differentiate DLB from AD and HCs. The pareidolia test required approximately 15 minutes to administer, exhibited good test-retest/inter-rater reliability (ICC of 0.82), and moderately correlated with the NPI hallucinations score (rs = 0.42). Using an optimal cut-off score set according to the ROC analysis, and the pareidolia test differentiated DLB from AD with a sensitivity of 81% and a specificity of 92%. Our study suggests that the simplified version of the pareidolia test is a valid and reliable surrogate marker of visual hallucinations in DLB.
Ramachandran, K.; Raj kumar, T.; Babu, K. Justice; Gnana kumar, G.
2016-01-01
The facile, time and cost efficient and environmental benign approach has been developed for the preparation of Nickel (Ni)-Cobalt (Co) alloy nanowires filled multiwalled carbon nanotubes (MWCNTs) with the aid of mesoporous silica nanoparticles (MSN)/Ni-Co catalyst. The controlled incorporation of Ni-Co nanostructures in the three dimensional (3D) pore structures of MSN yielded the catalytically active system for the MWCNT growth. The inner surface of MWCNTs was quasi-continuously filled with face-centered cubic (fcc) structured Ni-Co nanowires. The as-prepared nanostructures were exploited as non-enzymatic electrochemical sensor probes for the reliable detection of glucose. The electrochemical measurements illustrated that the fabricated sensor exhibited an excellent electrochemical performance toward glucose oxidation with a high sensitivity of 0.695 mA mM−1 cm−2, low detection limit of 1.2 μM, a wide linear range from 5 μM–10 mM and good selectivity. The unprecedented electrochemical performances obtained for the prepared nanocomposite are purely attributed to the synergistic effects of Ni-Co nanowires and MWCNTs. The constructed facile, selective and sensitive glucose sensor has also endowed its reliability in analyzing the human serum samples, which wide opened the new findings for exploring the novel nanostructures based glucose sensor devices with affordable cost and good stability. PMID:27833123
Gimeno-Santos, Elena; Raste, Yogini; Demeyer, Heleen; Louvaris, Zafeiris; de Jong, Corina; Rabinovich, Roberto A.; Hopkinson, Nicholas S.; Polkey, Michael I.; Vogiatzis, Ioannis; Tabberer, Maggie; Dobbels, Fabienne; Ivanoff, Nathalie; de Boer, Willem I.; van der Molen, Thys; Kulich, Karoly; Serra, Ignasi; Basagaña, Xavier; Troosters, Thierry; Puhan, Milo A.; Karlsson, Niklas
2015-01-01
No current patient-centred instrument captures all dimensions of physical activity in chronic obstructive pulmonary disease (COPD). Our objective was item reduction and initial validation of two instruments to measure physical activity in COPD. Physical activity was assessed in a 6-week, randomised, two-way cross-over, multicentre study using PROactive draft questionnaires (daily and clinical visit versions) and two activity monitors. Item reduction followed an iterative process including classical and Rasch model analyses, and input from patients and clinical experts. 236 COPD patients from five European centres were included. Results indicated the concept of physical activity in COPD had two domains, labelled “amount” and “difficulty”. After item reduction, the daily PROactive instrument comprised nine items and the clinical visit contained 14. Both demonstrated good model fit (person separation index >0.7). Confirmatory factor analysis supported the bidimensional structure. Both instruments had good internal consistency (Cronbach's α>0.8), test–retest reliability (intraclass correlation coefficient ≥0.9) and exhibited moderate-to-high correlations (r>0.6) with related constructs and very low correlations (r<0.3) with unrelated constructs, providing evidence for construct validity. Daily and clinical visit “PROactive physical activity in COPD” instruments are hybrid tools combining a short patient-reported outcome questionnaire and two activity monitor variables which provide simple, valid and reliable measures of physical activity in COPD patients. PMID:26022965
Gimeno-Santos, Elena; Raste, Yogini; Demeyer, Heleen; Louvaris, Zafeiris; de Jong, Corina; Rabinovich, Roberto A; Hopkinson, Nicholas S; Polkey, Michael I; Vogiatzis, Ioannis; Tabberer, Maggie; Dobbels, Fabienne; Ivanoff, Nathalie; de Boer, Willem I; van der Molen, Thys; Kulich, Karoly; Serra, Ignasi; Basagaña, Xavier; Troosters, Thierry; Puhan, Milo A; Karlsson, Niklas; Garcia-Aymerich, Judith
2015-10-01
No current patient-centred instrument captures all dimensions of physical activity in chronic obstructive pulmonary disease (COPD). Our objective was item reduction and initial validation of two instruments to measure physical activity in COPD.Physical activity was assessed in a 6-week, randomised, two-way cross-over, multicentre study using PROactive draft questionnaires (daily and clinical visit versions) and two activity monitors. Item reduction followed an iterative process including classical and Rasch model analyses, and input from patients and clinical experts.236 COPD patients from five European centres were included. Results indicated the concept of physical activity in COPD had two domains, labelled "amount" and "difficulty". After item reduction, the daily PROactive instrument comprised nine items and the clinical visit contained 14. Both demonstrated good model fit (person separation index >0.7). Confirmatory factor analysis supported the bidimensional structure. Both instruments had good internal consistency (Cronbach's α>0.8), test-retest reliability (intraclass correlation coefficient ≥0.9) and exhibited moderate-to-high correlations (r>0.6) with related constructs and very low correlations (r<0.3) with unrelated constructs, providing evidence for construct validity.Daily and clinical visit "PROactive physical activity in COPD" instruments are hybrid tools combining a short patient-reported outcome questionnaire and two activity monitor variables which provide simple, valid and reliable measures of physical activity in COPD patients. Copyright ©ERS 2015.
NASA Astrophysics Data System (ADS)
Ramachandran, K.; Raj Kumar, T.; Babu, K. Justice; Gnana Kumar, G.
2016-11-01
The facile, time and cost efficient and environmental benign approach has been developed for the preparation of Nickel (Ni)-Cobalt (Co) alloy nanowires filled multiwalled carbon nanotubes (MWCNTs) with the aid of mesoporous silica nanoparticles (MSN)/Ni-Co catalyst. The controlled incorporation of Ni-Co nanostructures in the three dimensional (3D) pore structures of MSN yielded the catalytically active system for the MWCNT growth. The inner surface of MWCNTs was quasi-continuously filled with face-centered cubic (fcc) structured Ni-Co nanowires. The as-prepared nanostructures were exploited as non-enzymatic electrochemical sensor probes for the reliable detection of glucose. The electrochemical measurements illustrated that the fabricated sensor exhibited an excellent electrochemical performance toward glucose oxidation with a high sensitivity of 0.695 mA mM-1 cm-2, low detection limit of 1.2 μM, a wide linear range from 5 μM-10 mM and good selectivity. The unprecedented electrochemical performances obtained for the prepared nanocomposite are purely attributed to the synergistic effects of Ni-Co nanowires and MWCNTs. The constructed facile, selective and sensitive glucose sensor has also endowed its reliability in analyzing the human serum samples, which wide opened the new findings for exploring the novel nanostructures based glucose sensor devices with affordable cost and good stability.
Lower-limb kinematics of single-leg squat performance in young adults.
Horan, Sean A; Watson, Steven L; Carty, Christopher P; Sartori, Massimo; Weeks, Benjamin K
2014-01-01
To determine the kinematic parameters that characterize good and poor single-leg squat (SLS) performance. A total of 22 healthy young adults free from musculoskeletal impairment were recruited for testing. For each SLS, both two-dimensional video and three-dimensional motion analysis data were collected. Pelvis, hip, and knee angles were calculated using a reliable and validated lower-limb (LL) biomechanical model. Two-dimensional video clips of SLSs were blindly assessed in random order by eight musculoskeletal physiotherapists using a 10-point ordinal scale. To facilitate between-group comparisons, SLS performances were stratified by tertiles corresponding to poor, intermediate, and good SLS performance. Mean ratings of SLS performance assessed by physiotherapists were 8.3 (SD 0.5), 6.8 (SD 0.7), and 4.0 (SD 0.8) for good, intermediate, and poor squats, respectively. Three-dimensional analysis revealed that people whose SLS performance was assessed as poor exhibited increased hip adduction, reduced knee flexion, and increased medio-lateral displacement of the knee joint centre compared to those whose SLS performance was assessed as good (p≤0.05). Overall, poor SLS performance is characterized by inadequate knee flexion and excessive frontal plane motion of the knee and hip. Future investigations of SLS performance should consider standardizing knee flexion angle to illuminate other influential kinematic parameters.
Reliability of a novel serious game using dual-task gait profiles to early characterize aMCI
Tarnanas, Ioannis; Papagiannopoulos, Sotirios; Kazis, Dimitris; Wiederhold, Mark; Widerhold, Brenda; Tsolaki, Magda
2015-01-01
Background: As the population of older adults is growing, the interest in a simple way to detect characterize amnestic mild cognitive impairment (aMCI), a prodromal stage of Alzheimer’s disease (AD), is becoming increasingly important. Serious game (SG) -based cognitive and motor performance profiles while performing everyday activities and dual-task walking (DTW) “motor signatures” are two very promising markers that can be detected in predementia states. We aim to compare the consistency, or conformity, of measurements made by a custom SG with DTW (NAV), a SG without DTW (DOT), neuropsychological measures and genotyping as markers for early detection of aMCI. Methods: The study population included three groups: early AD (n = 86), aMCI (n = 65), and healthy control subjects (n = 76), who completed the custom SG tasks in three separate sessions over a 3-month period. Outcome measures were neuropsychological data across-domain and within-domain intra-individual variability (IIV) and DOT and NAV latency-based and accuracy-based IIV. IIV reflects a transient, within-person change in behavioral performance, either during different cognitive domains (across-domain) or within the same domain (within-domain). Test–retest reliability of the DOT and NAV markers were assessed using an intraclass correlation (ICC) analysis. Results: Results indicated that performance data, such as the NAV latency-based and accuracy-based IIV, during the task displayed greater reliability across sessions compared to DOT. During the NAV task-engagement, the executive function, planning, and motor performance profiles exhibited moderate to good reliability (ICC = 0.6–0.8), while during DOT, executive function and spatial memory accuracy profiles exhibited fair to moderate reliability (ICC = 0.3–0.6). Additionally, reliability across tasks was more stable when three sessions were used in the ICC calculation relative to two sessions. Discussion: Our findings suggest that “motor signature” data during the NAV tasks were a more reliable marker for early diagnosis of aMCI than DOT. This result accentuates the importance of utilizing motor performance data as a metric for aMCI populations where memory decline is often the behavioral outcome of interest. In conclusion, custom SG with DTW performance data provide an ecological and reliable approach for cognitive assessment across multiple sessions and thus can be used as a useful tool for tracking longitudinal change in observational and interventional studies on aMCI. PMID:25954193
NASA Astrophysics Data System (ADS)
Kobayashi, Shunsuke; Furuta, Hirokazu; Murakami, Yuji; Xu, Jun; Mochizuki, Akihiro
2003-04-01
Defect free polymer-stabilized (PS-)V-mode FLCDs and intrinsic half (H-)V-mode FLCDs have been fabricated; they exhibit high contrast ratio over 700:1 and high reliability for a temperature cycling test by using specially developed polyimide alignment materials, RN-1411 series, from Nissan Chem. Ind., and also by adopting special alignment technique such as appropriate rubbing technique, photoalignment, and ion beam irradiation techniques and also particularly developed polymer-stabilization technique. These FLCDs are shown to be useful for implementing a field sequential type full color (FS-FC) LCDs due to their fast response with the response time of τ = 100μs ~ 500μs that is 10 to 100 times faster that those of LCDs using NLCs. We have developed several prototype models of FS-FC LCDs having VGA specifications that exhibit good performance for displaying fast moving video rate images with wide color gamut.
Pompilus, Farrah; Burgess, Somali; Hudgens, Stacie; Banderas, Benjamin; Daniels, Selena
2015-12-01
Facial lines or wrinkles are among the most visible signs of aging, and minimally invasive cosmetic procedures are becoming increasingly popular. The aim of this study was to develop and validate the Facial Line Satisfaction Questionnaire (FLSQ) for use in adults with upper facial lines (UFL). A literature review, concept elicitation interviews (n = 33), and cognitive debriefing interviews (n = 23) of adults with UFL were conducted to develop the FLSQ. The FLSQ comprises Baseline and Follow-up versions and was field-tested with 150 subjects in a US observational study designed to assess its psychometric performance. Analyses included acceptability (item and scale distribution [i.e. missingness, floor, and ceiling effects]), reliability, and validity (including concurrent validity). In total, 69 concepts were elicited during patient interviews. Following cognitive debriefing interviews, the FLSQ-Baseline version included 11 items and the Follow-up version included 13 items. Response rates for the FLSQ were 100% and 73% at baseline and follow-up, respectively; no items had excessive missing data. Questionnaire scale scores were normally distributed. Most domain scores demonstrated good internal consistency reliability (Cronbach's α ≥ 0.70). Most items within their respective domains exhibited good convergent (item-scale correlations > 0.40) and discriminant (items had higher correlation with their hypothesized scales than other scales) validity. Concurrent validity correlation coefficients of the FLSQ domain scores with the associated concurrent measures were acceptable (range: r = 0.40-0.70). Six FLSQ items demonstrated reliability and validity as stand-alone items outside their domains. The FLSQ is a valid questionnaire for assessing treatment expectations, satisfaction, impact, and preference in adults with UFL. © 2015 The Authors. Journal of Cosmetic Dermatology Published by Wiley Periodicals, Inc.
Korakakis, Vasileios; Patsiaouras, Asterios; Malliaropoulos, Nikos
2014-12-01
To cross-culturally adapt the VISA-P questionnaire for Greek-speaking patients and evaluate its psychometric properties. The VISA-P was developed in the English language to evaluate patients with patellar tendinopathy. The validity and use of self-administered questionnaires in different language and cultural populations require a specific procedure in order to maintain their content validity. The VISA-P questionnaire was translated and cross-culturally adapted according to specific guidelines. The validity and reliability were tested in 61 healthy recreational athletes, 64 athletes at risk from different sports, 32 patellar tendinopathy patients and 30 patients with other knee injuries. Participants completed the questionnaire at baseline and after 15-17 days. The questionnaire's face and content validity were judged as good by the expert committee, and the participants. Concurrent validity was almost perfect (ρ=-0.839, p<0.001). Also, factorial validity testing revealed a two-factor solution, which explained 85.6% of the total variance. A one-factor solution explained 80.8% of the variance when the other knee injury group was excluded. Known group validity was demonstrated by significant differences between patients compared with the asymptomatic groups (p<0.001). The VISA-P-GR exhibited very good test-retest reliability (ICC=0.818, p<0.001; 95% CI 0.758 to 0.864) and internal consistency since Cronbach's α analysis ranged from α=0.785 to 0.784 following a 15-17 days interval. The translated VISA-P-GR is a valid and reliable questionnaire and its psychometric properties are comparable with the original and adapted versions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Randhawa, Sharan; Walterfang, Mark; Miller, Kathryn; Scholes, Amelia; Mocellin, Ramon; Velakoulis, Dennis
2007-07-01
The carer history is an integral part of the assessment of patients with cognitive impairment. We aimed to develop a comprehensive yet concise carer questionnaire, the CogRisk, which captures actuarial risk variables for cognitive impairment in addition to key symptoms suggestive of cognitive decline in a number of cognitive domains, and to then assess its validity and reliability in a neuropsychiatric population. Carers of patients assessed for cognitive impairment completed the CogRisk, and patients were clinically assessed using the Mini-Mental State Examination (MMSE) and Neuropsychiatry Unit COGnitive assessment tool (NUCOG). Reliability was assessed using test-retest and interrater measures and measures of internal consistency. Construct and concurrent validity was assessed using correlation between total and subscale scores on the CogRisk, total scores on the NUCOG and MMSE, and subscale scores on the NUCOG. Predictive validity was determined using measures of sensitivity and specificity and using receiver operating characteristic (ROC) methods. The CogRisk was completed by all carers in less than 10 min. The total CogRisk score correlated significantly with total MMSE and NUCOG scores (r=-0.511 and -0.563, respectively) and remained highly significant when age and education were controlled for. Internal consistency of CogRisk items was high (alpha=0.943). Intrarater reliability of the CogRisk was high with an intraclass correlation coefficient of .978 (P<.001), and interrater reliability between carers was also high at 0.868 (P<.05). Sensitivity and specificity for the detection of dementia were .70 and .73, respectively, with area under the ROC curve not significantly different from that of the MMSE or NUCOG. The CogRisk is a brief carer-rated tool of a patient's cognitive functioning developed for use within a neuropsychiatric setting. It exhibited good concurrent validity, internal consistency, and interrater and intrarater reliability. The CogRisk also demonstrated good sensitivity and specificity for dementia. The CogRisk provides carer information, which complements the clinical assessment and can be used to focus on direct carer interview.
Chakroun-Baggioni, Nadia; Corman, Maya; Spada, Marcantonio M; Caselli, Gabriele; Gierski, Fabien
2017-10-01
Desire thinking and mindfulness have been associated with craving. The aim of the present study was to validate the French version of the Desire Thinking Questionnaire (DTQ) and to investigate the relationship between mindfulness, desire thinking and craving among a sample of university students. Four hundred and ninety six university students completed the DTQ and measures of mindfulness, craving and alcohol use. Results from confirmatory factor analyses showed that the two-factor structure proposed in the original DTQ exhibited suitable goodness-of-fit statistics. The DTQ also demonstrated good internal reliability, temporal stability and predictive validity. A set of linear regressions revealed that desire thinking had a confounding effect in the relationship between mindfulness and craving. The confounding role of desire thinking in the relationship between mindfulness and craving suggests that interrupting desire thinking may be a viable clinical option aimed at reducing craving. Copyright © 2017 Elsevier B.V. All rights reserved.
Simultaneous voltammetric determination of prednisone and prednisolone in human body fluids.
Goyal, Rajendra N; Bishnoi, Sunita
2009-08-15
A sensitive, rapid and reliable electrochemical method based on voltammetry at single wall carbon nanotube (SWNT) modified edge plane pyrolytic graphite electrode (EPPGE) is proposed for the simultaneous determination of prednisolone and prednisone in human body fluids and pharmaceutical preparations. The electrochemical response of both the drugs was evaluated by osteryoung square wave voltammetry (OSWV) in phosphate buffer medium of pH 7.2. The modified electrode exhibited good electrocatalytic properties towards prednisone and prednisolone reduction with a peak potential of approximately -1230 and approximately -1332 mV respectively. The concentration versus peak current plots were linear for both the analytes in the range 0.01-100 microM and the detection limit (3 sigma/slope) observed for prednisone and prednisolone were 0.45 x 10(-8), 0.90 x 10(-8)M, respectively. The results of the quantitative estimation of prednisone and prednisolone in biological fluids were also compared with HPLC and the results were in good agreement.
Liu, Hung-Chuan; Lai, Yi-Chun; Lai, Chih-Chung; Wu, Bing-Shu; Zan, Hsiao-Wen; Yu, Peichen; Chueh, Yu-Lun; Tsai, Chuang-Chuang
2015-01-14
In this work, we demonstrate sputtered amorphous indium-gallium-zinc oxide thin-film transistors (a-IGZO TFTs) with a record high effective field-effect mobility of 174 cm(2)/V s by incorporating silver nanowire (AgNW) arrays to channel electron transport. Compared to the reference counterpart without nanowires, the over 5-fold enhancement in the effective field-effect mobility exhibits clear dependence on the orientation as well as the surface coverage ratio of silver nanowires. Detailed material and device analyses reveal that during the room-temperature IGZO sputtering indium and oxygen diffuse into the nanowire matrix while the nanowire morphology and good contact between IGZO and nanowires are maintained. The unchanged morphology and good interfacial contact lead to high mobility and air-ambient-stable characteristics up to 3 months. Neither hysteresis nor degraded bias stress reliability is observed. The proposed AgNW-mediated a-IGZO TFTs are promising for development of large-scale, flexible, transparent electronics.
Enhancing reproducibility of SALDI MS detection by concentrating analytes within laser spot.
Teng, Fei; Zhu, Qunyan; Wang, Yalei; Du, Juan; Lu, Nan
2018-03-01
Surface-assisted laser desorption/ionization time-of-flight mass spectrometry (SALDI TOF MS) has become one of the most important analytical methods due to its less interference at low molecular weight range. However, it is still a challenge to obtain a good reproducibility of SALDI TOF MS because of the inhomogeneous distribution of analyte molecules induced by coffee ring effect. We propose a universal and reliable method to eliminate the coffee ring effect by concentrating all the analyte molecules within the laser spot. This method exhibits an excellent reproducibility of spot-to-spot and substrate-to-substrate, and the relative standard deviations (RSDs) for different concentrations are lower than 12.6%. It also performs good linear dependency (R 2 > 0.98) in the log-log plot with the concentration range of 1nM to 1μM, and the limit of detection for R6G is down to 1fmol. Copyright © 2017 Elsevier B.V. All rights reserved.
A comparison of three developmental stage scoring systems.
Dawson, Theo Linda
2002-01-01
In social psychological research the stage metaphor has fallen into disfavor due to concerns about bias, reliability, and validity. To address some of these issues, I employ a multidimensional partial credit analysis comparing moral judgment interviews scored with the Standard Issue Scoring System (SISS) (Colby and Kohlberg, 1987b), evaluative reasoning interviews scored with the Good Life Scoring System (GLSS) (Armon, 1984b), and Good Education interviews scored with the Hierarchical Complexity Scoring System (HCSS) (Commons, Danaher, Miller, and Dawson, 2000). A total of 209 participants between the ages of 5 and 86 were interviewed. The multidimensional model reveals that even though the scoring systems rely upon different criteria and the data were collected using different methods and scored by different teams of raters, the SISS, GLSS, and HCSS all appear to measure the same latent variable. The HCSS exhibits more internal consistency than the SISS and GLSS, and solves some methodological problems introduced by the content dependency of the SISS and GLSS. These results and their implications are elaborated.
Inter-rater reliability of three standardized functional tests in patients with low back pain
Tidstrand, Johan; Horneij, Eva
2009-01-01
Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs). Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ) and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0), for sitting on a Bobath ball good (κ: 0.79) and very good (κ: 0.88) and for the unilateral pelvic lift: good (κ: 0.61) and moderate (κ: 0.47). Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their ability to evaluate lumbar stability is required. PMID:19490644
Reliability analysis for digital adolescent idiopathic scoliosis measurements.
Kuklo, Timothy R; Potter, Benjamin K; O'Brien, Michael F; Schroeder, Teresa M; Lenke, Lawrence G; Polly, David W
2005-04-01
Analysis of adolescent idiopathic scoliosis (AIS) requires a thorough clinical and radiographic evaluation to completely assess the three-dimensional deformity. Recently, these radiographic parameters have been analyzed for reliability and reproducibility following manual measurements; however, most of these parameters have not been analyzed with regard to digital measurements. The purpose of this study is to determine the intra- and interobserver reliability of common scoliosis radiographic parameters using a digital software measurement program. Thirty sets of preoperative (posteroanterior [PA], lateral, and side-bending [SB]) and postoperative (PA and lateral) radiographs were analyzed by three independent observers on two separate occasions using a software measurement program (PhDx, Albuquerque, NM). Coronal measures included main thoracic (MT) and thoracolumbar-lumbar (TL/L) Cobb, SB MT Cobb, MT and TL/L apical vertical translation (AVT), C7 to center sacral vertical line (CSVL), T1 tilt, LIV tilt, disk below lowest instrumented vertebra (LIV), coronal balance, and Risser, whereas sagittal measures included T2-T5, T5-T12, T2-T12, T10-L2, T12-S1, and sagittal balance. Analysis of variance for repeated measures or Cohen three-way kappa correlation coefficient analysis was performed as appropriate to calculate the intra- and interobserver reliability for each parameter. The majority of the radiographic parameters assessed demonstrated good or excellent intra- and interobserver reliability. The relationship of the LIV to the CSVL (intraobserver kappaa = 0.48-0.78, fair to excellent; interobserver kappaa = 0.34-0.41, fair to poor), interobserver measurement of AVT (rho = 0.49-0.73, low to good), Risser grade (intraobserver rho = 0.41-0.97, low to excellent; interobserver rho = 0.60-0.70, fair to good), intraobserver measurement of the angulation of the disk inferior to the LIV (rho = 0.53-0.88, fair to good), apical Nash-Moe vertebral rotation (intraobserver rho = 0.50-0.85, fair to good; interobserver rho = 0.53-0.59, fair), and especially regional thoracic kyphosis from T2 to T5 (intraobserver rho = 0.22-0.65, poor to fair; interobserver rho = 0.33-0.47, low) demonstrated lesser reliability. In general, preoperative measures demonstrated greater reliability than postoperative measures, and coronal angular measures were more reliable than sagittal measures. Most common radiographic parameters for AIS assessment demonstrated good or excellent reliability for digital measurement and can be recommended for routine clinical and academic use. Preoperative assessments and coronal measures may be more reliable than postoperative and sagittal measurements. The reliability of digital measurements will be increasingly important as digital radiographic viewing becomes commonplace.
Tepe, Rodger; Tepe, Chabha
2015-03-01
To develop and psychometrically evaluate an information literacy (IL) self-efficacy survey and an IL knowledge test. In this test-retest reliability study, a 25-item IL self-efficacy survey and a 50-item IL knowledge test were developed and administered to a convenience sample of 53 chiropractic students. Item analyses were performed on all questions. The IL self-efficacy survey demonstrated good reliability (test-retest correlation = 0.81) and good/very good internal consistency (mean κ = .56 and Cronbach's α = .92). A total of 25 questions with the best item analysis characteristics were chosen from the 50-item IL knowledge test, resulting in a 25-item IL knowledge test that demonstrated good reliability (test-retest correlation = 0.87), very good internal consistency (mean κ = .69, KR20 = 0.85), and good item discrimination (mean point-biserial = 0.48). This study resulted in the development of three instruments: a 25-item IL self-efficacy survey, a 50-item IL knowledge test, and a 25-item IL knowledge test. The information literacy self-efficacy survey and the 25-item version of the information literacy knowledge test have shown preliminary evidence of adequate reliability and validity to justify continuing study with these instruments.
Tepe, Rodger; Tepe, Chabha
2015-01-01
Objective To develop and psychometrically evaluate an information literacy (IL) self-efficacy survey and an IL knowledge test. Methods In this test–retest reliability study, a 25-item IL self-efficacy survey and a 50-item IL knowledge test were developed and administered to a convenience sample of 53 chiropractic students. Item analyses were performed on all questions. Results The IL self-efficacy survey demonstrated good reliability (test–retest correlation = 0.81) and good/very good internal consistency (mean κ = .56 and Cronbach's α = .92). A total of 25 questions with the best item analysis characteristics were chosen from the 50-item IL knowledge test, resulting in a 25-item IL knowledge test that demonstrated good reliability (test–retest correlation = 0.87), very good internal consistency (mean κ = .69, KR20 = 0.85), and good item discrimination (mean point-biserial = 0.48). Conclusions This study resulted in the development of three instruments: a 25-item IL self-efficacy survey, a 50-item IL knowledge test, and a 25-item IL knowledge test. The information literacy self-efficacy survey and the 25-item version of the information literacy knowledge test have shown preliminary evidence of adequate reliability and validity to justify continuing study with these instruments. PMID:25517736
2010-01-01
Background Tasks chosen to evaluate motor performance should reflect the movement deficits characteristic of the target population and present an appropriate challenge for the patients who would be evaluated. A reaching task that evaluates impairment characteristics of people with shoulder impingement syndrome (SIS) was developed to evaluate the motor performance of this population. The objectives of this study were to characterize the reproducibility of this reaching task in people with and without SIS and to evaluate the impact of the number of trials on reproducibility. Methods Thirty subjects with SIS and twenty healthy subjects participated in the first measurement session to evaluate intrasession reliability. Ten healthy subjects were retested within 2 to 7 days to assess intersession reliability. At each measurement session, upper extremity kinematic patterns were evaluated during a reaching task. Ten trials were recorded. Thereafter, the upper extremity position at the end of reaching and total joint excursion that occurred during reaching were calculated. Intraclass correlation coefficient (ICC) and minimal detectable change (MDC) were used to estimate intra and intersession reliability. Results Intrasession reliability for total joint excursion was good to very good when based on the first two trials (0.77
van de Pol, Daan; Zacharian, Tigran; Maas, Mario; Kuijer, P Paul F M
2017-06-01
The Shoulder posterior circumflex humeral artery Pathology and digital Ischemia - questionnaire (SPI-Q) has been developed to enable periodic surveillance of elite volleyball players, who are at risk for digital ischemia. Prior to implementation, assessing reliability is mandatory. Therefore, the test-retest reliability and agreement of the SPI-Q were evaluated among the population at risk. A questionnaire survey was performed with a 2-week interval among 65 elite male volleyball players assessing symptoms of cold, pale and blue digits in the dominant hand during or after practice or competition using a 4-point Likert scale (never, sometimes, often and always). Kappa (κ) and percentage of agreement (POA) were calculated for individual symptoms, and to distinguish symptomatic and asymptomatic players. For the individual symptoms, κ ranged from "poor" (0.25) to "good" (0.63), and POA ranged from "moderate" (78%) to "good" (97%). To classify symptomatic players, the SPI-Q showed "good" reliability (κ = 0.83; 95%CI 0.69-0.97) and "good" agreement (POA = 92%). The current study has proven the SPI-Q to be reliable for detecting elite male indoor volleyball players with symptoms of digital ischemia.
Reliability of quantitative EEG (qEEG) measures and LORETA current source density at 30 days.
Cannon, Rex L; Baldwin, Debora R; Shaw, Tiffany L; Diloreto, Dominic J; Phillips, Sherman M; Scruggs, Annie M; Riehl, Timothy C
2012-06-14
There is a growing interest for using quantitative EEG and LORETA current source density in clinical and research settings. Importantly, if these indices are to be employed in clinical settings then the reliability of these measures is of great concern. Neuroguide (Applied Neurosciences) is sophisticated software developed for the analyses of power, and connectivity measures of the EEG as well as LORETA current source density. To date there are relatively few data evaluating topographical EEG reliability contrasts for all 19 channels and no studies have evaluated reliability for LORETA calculations. We obtained 4 min eyes-closed and eyes-opened EEG recordings at 30-day intervals. The EEG was analyzed in Neuroguide and FFT power, coherence and phase was computed for traditional frequency bands (delta, theta, alpha and beta) and LORETA current source density was calculated in 1 Hz increments and summed for total power in eight regions of interest (ROI). In order to obtain a robust measure of reliability we utilized a random effects model with an absolute agreement definition. The results show very good reproducibility for total absolute power and coherence. Phase shows lower reliability coefficients. LORETA current source density shows very good reliability with an average 0.81 for ECB and 0.82 for EOB. Similarly, the eight regions of interest show good to very good agreement across time. Implications for future directions and use of qEEG and LORETA in clinical populations are discussed. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Long, Hu; Harley-Trochimczyk, Anna; Cheng, Siyi; Hu, Hao; Chi, Won Seok; Rao, Ameya; Carraro, Carlo; Shi, Tielin; Tang, Zirong; Maboudian, Roya
2016-11-23
Nanowire-assembled 3D hierarchical ZnCo 2 O 4 microstructure is synthesized by a facile hydrothermal route and a subsequent annealing process. In comparison to simple nanowires, the resulting dandelion-like structure yields more open spaces between nanowires, which allow for better gas diffusion and provide more active sites for gas adsorption while maintaining good electrical conductivity. The hierarchical ZnCo 2 O 4 microstructure is integrated on a low-power microheater platform without using binders or conductive additives. The hierarchical structure of the ZnCo 2 O 4 sensing material provides reliable electrical connection across the sensing electrodes. The resulting sensor exhibits an ultralow detection limit of 3 ppb toward formaldehyde with fast response and recovery as well as good selectivity to CO, H 2 , and hydrocarbons such as n-pentane, propane, and CH 4 . The sensor only consumes ∼5.7 mW for continuous operation at 300 °C with good long-term stability. The excellent sensing performance of this hierarchical structure based sensor suggests the advantages of combining such structures with microfabricated heaters for practical low-power sensing applications.
Shipley, Hilary; Guedes, Alonso; Graham, Lynelle; Goudie-DeAngelis, Elizabeth; Wendt-Hornickle, Erin
2018-05-01
Objectives The objective of this study was to determine the inter-rater reliability and convergent validity of the Colorado State University Feline Acute Pain Scale (CSU-FAPS) in a preliminary appraisal of its performance in a clinical teaching setting. Methods Sixty-eight female cats were assessed for pain after ovariohysterectomy. A cohort of 21 cats was examined independently by four raters (two board-certified anesthesiologists and two anesthesia residents) with the CSU-FAPS, and intra-class correlation coefficient (ICC) was used to determine inter-rater reliability. Weighted Cohen's kappa was used to determine inter-rater reliability centered on the 'need to reassess analgesic plan' (dichotomous scale). A separate cohort of 47 cats was evaluated independently by two raters (one board-certified anesthesiologist and one veterinary small animal rotating intern) using the CSU-FAPS and the Glasgow Composite Measure Pain Scale (CMPS-Feline), and Spearman rank-order correlation was determined to assess convergent validity. Reliability was interpreted using Altman's classification as very good, good, moderate, fair and poor. Validity was considered adequate if correlation coefficients were between 0.4 and 0.8. Results The ICC was 0.61 for anesthesiologists and 0.67 for residents, indicating good reliability. Weighted Cohen's kappa was 0.79 for anesthesiologists and 0.44 for residents, indicating moderate to good reliability. The Spearman rank correlation indicated a statistically significant ( P = 0.0003) positive correlation (0.31; 95% confidence interval 0.14-0.46) between the CSU-FAPS and the CMPS-Feline. Conclusions and relevance The CSU-FAPS showed moderate-to-good inter-rater reliability when used by veterinarians to assess pain level or need to reassess analgesic plan after ovariohysterectomy in cats. The validity fell short of current guidelines for correlation coefficients and further refinement and testing are warranted to improve its performance.
Development and validation of a questionnaire to evaluate infection control in oral radiology
Pinelli, Camila; da Silva Tagliaferro, Elaine P; Corrente, José E; Ambrosano, Glaucia M B
2017-01-01
Objectives: To create and validate a questionnaire to evaluate infection control in oral radiology. Methods: The questionnaire was developed after review of the literature, which included published articles and the biosafety protocols available from healthcare agencies. The initial version of the questionnaire was composed of 14 multiple choice questions and was divided into 3 domains on handwashing, disinfection/protection of surfaces and disinfectant used. Content validity was assessed by two expert committees, which reviewed the content and scope of the questionnaire and the relevance of each item, respectively. Reliability was evaluated using test–retest and internal consistency methods with 115 undergraduate dentistry students. Construct validity was assessed using the known-groups technique and factor analysis. The known-groups technique involved 641 undergraduate dentistry students, 20 PhD students and 15 oral radiology professors. In the factor analysis, 3 radiology technicians also participated in addition to the 641 undergraduates, 20 PhD students and 15 oral radiology professors. Results: The content validity results were found to be satisfactory to excellent for the ordinal variables (intraclass correlation coefficient = 0.722–1.000) and good to great for the yes/no questions (kappa = 0.662–0.913) in terms of reliability and good internal consistency (Cronbach's alpha = 0.88). After a factor analysis, some questions were excluded, and the questions were grouped into new domains. Significant differences were observed between answers from different groups. The final version of the questionnaire was composed of nine domains. Conclusions: The questionnaire created was found to exhibit good psychometric properties for assessing infection control in oral radiology. PMID:28112553
Huang, Ke-Jing; Niu, De-Jun; Sun, Jun-Yong; Han, Cong-Hui; Wu, Zhi-Wei; Li, Yan-Li; Xiong, Xiao-Qin
2011-02-01
A nano-material carboxylic acid functionalized graphene (graphene-COOH) was prepared and used to construct a novel biosensor for the simultaneous detection of adenine and guanine. The direct electrooxidation behaviors of adenine and guanine on the graphene-COOH modified glassy carbon electrode (graphene-COOH/GCE) were carefully investigated by cyclic voltammetry and differential pulse voltammetry. The results indicated that both adenine and guanine showed the increase of the oxidation peak currents with the negative shift of the oxidation peak potentials in contrast to that on the bare glassy carbon electrode. The electrochemical parameters of adenine and guanine on the graphene-COOH/GCE were calculated and a simple and reliable electroanalytical method was developed for the detection of adenine and guanine, respectively. The modified electrode exhibited good behaviors in the simultaneous detection of adenine and guanine with the peak separation as 0.334V. The detection limit for individual determination of guanine and adenine was 5.0×10(-8)M and 2.5×10(-8)M (S/N=3), respectively. Furthermore, the measurements of thermally denatured single-stranded DNA were carried out and the value of (G+C)/(A+T) of single-stranded DNA was calculated as 0.80. The biosensor exhibited some advantages, such as simplicity, rapidity, high sensitivity, good reproducibility and long-term stability. Copyright © 2010 Elsevier B.V. All rights reserved.
Boser, Quinn A; Valevicius, Aïda M; Lavoie, Ewen B; Chapman, Craig S; Pilarski, Patrick M; Hebert, Jacqueline S; Vette, Albert H
2018-04-27
Quantifying angular joint kinematics of the upper body is a useful method for assessing upper limb function. Joint angles are commonly obtained via motion capture, tracking markers placed on anatomical landmarks. This method is associated with limitations including administrative burden, soft tissue artifacts, and intra- and inter-tester variability. An alternative method involves the tracking of rigid marker clusters affixed to body segments, calibrated relative to anatomical landmarks or known joint angles. The accuracy and reliability of applying this cluster method to the upper body has, however, not been comprehensively explored. Our objective was to compare three different upper body cluster models with an anatomical model, with respect to joint angles and reliability. Non-disabled participants performed two standardized functional upper limb tasks with anatomical and cluster markers applied concurrently. Joint angle curves obtained via the marker clusters with three different calibration methods were compared to those from an anatomical model, and between-session reliability was assessed for all models. The cluster models produced joint angle curves which were comparable to and highly correlated with those from the anatomical model, but exhibited notable offsets and differences in sensitivity for some degrees of freedom. Between-session reliability was comparable between all models, and good for most degrees of freedom. Overall, the cluster models produced reliable joint angles that, however, cannot be used interchangeably with anatomical model outputs to calculate kinematic metrics. Cluster models appear to be an adequate, and possibly advantageous alternative to anatomical models when the objective is to assess trends in movement behavior. Copyright © 2018 Elsevier Ltd. All rights reserved.
O'Neil, Margaret E; Fragala-Pinkham, Maria; Lennon, Nancy; George, Ameeka; Forman, Jeffrey; Trost, Stewart G
2016-01-01
Physical therapy for youth with cerebral palsy (CP) who are ambulatory includes interventions to increase functional mobility and participation in physical activity (PA). Thus, reliable and valid measures are needed to document PA in youth with CP. The purpose of this study was to evaluate the inter-instrument reliability and concurrent validity of 3 accelerometer-based motion sensors with indirect calorimetry as the criterion for measuring PA intensity in youth with CP. Fifty-seven youth with CP (mean age=12.5 years, SD=3.3; 51% female; 49.1% with spastic hemiplegia) participated. Inclusion criteria were: aged 6 to 20 years, ambulatory, Gross Motor Function Classification System (GMFCS) levels I through III, able to follow directions, and able to complete the full PA protocol. Protocol activities included standardized activity trials with increasing PA intensity (resting, writing, household chores, active video games, and walking at 3 self-selected speeds), as measured by weight-relative oxygen uptake (in mL/kg/min). During each trial, participants wore bilateral accelerometers on the upper arms, waist/hip, and ankle and a portable indirect calorimeter. Intraclass coefficient correlations (ICCs) were calculated to evaluate inter-instrument reliability (left-to-right accelerometer placement). Spearman correlations were used to examine concurrent validity between accelerometer output (activity and step counts) and indirect calorimetry. Friedman analyses of variance with post hoc pair-wise analyses were conducted to examine the validity of accelerometers to discriminate PA intensity across activity trials. All accelerometers exhibited excellent inter-instrument reliability (ICC=.94-.99) and good concurrent validity (rho=.70-.85). All accelerometers discriminated PA intensity across most activity trials. This PA protocol consisted of controlled activity trials. Accelerometers provide valid and reliable measures of PA intensity among youth with CP. © 2016 American Physical Therapy Association.
Retest reliability of individual alpha ERD topography assessed by human electroencephalography.
Vázquez-Marrufo, Manuel; Galvao-Carmona, Alejandro; Benítez Lugo, María Luisa; Ruíz-Peña, Juan Luis; Borges Guerra, Mónica; Izquierdo Ayuso, Guillermo
2017-01-01
Despite the immense literature related to diverse human electroencephalographic (EEG) parameters, very few studies have focused on the reliability of these measures. Some of the most studied components (i.e., P3 or MMN) have received more attention regarding the stability of their main parameters, such as latency, amplitude or topography. However, spectral modulations have not been as extensively evaluated considering that different analysis methods are available. The main aim of the present study is to assess the reliability of the latency, amplitude and topography of event-related desynchronization (ERD) for the alpha band (10-14 Hz) observed in a cognitive task (visual oddball). Topography reliability was analysed at different levels (for the group, within-subjects individually and between-subjects individually). The latency for alpha ERD showed stable behaviour between two sessions, and the amplitude exhibited an increment (more negative) in the second session. Alpha ERD topography exhibited a high correlation score between sessions at the group level (r = 0.903, p<0.001). The mean value for within-subject correlations was 0.750 (with a range from 0.391 to 0.954). Regarding between-subject topography comparisons, some subjects showed a highly specific topography, whereas other subjects showed topographies that were more similar to those of other subjects. ERD was mainly stable between the two sessions with the exception of amplitude, which exhibited an increment in the second session. Topography exhibits excellent reliability at the group level; however, it exhibits highly heterogeneous behaviour at the individual level. Considering that the P3 was previously evaluated for this group of subjects, a direct comparison of the correlation scores was possible, and it showed that the ERD component is less reliable in individual topography than in the ERP component (P3).
Retest reliability of individual alpha ERD topography assessed by human electroencephalography
Vázquez-Marrufo, Manuel; Benítez Lugo, María Luisa; Ruíz-Peña, Juan Luis; Borges Guerra, Mónica; Izquierdo Ayuso, Guillermo
2017-01-01
Background Despite the immense literature related to diverse human electroencephalographic (EEG) parameters, very few studies have focused on the reliability of these measures. Some of the most studied components (i.e., P3 or MMN) have received more attention regarding the stability of their main parameters, such as latency, amplitude or topography. However, spectral modulations have not been as extensively evaluated considering that different analysis methods are available. The main aim of the present study is to assess the reliability of the latency, amplitude and topography of event-related desynchronization (ERD) for the alpha band (10–14 Hz) observed in a cognitive task (visual oddball). Topography reliability was analysed at different levels (for the group, within-subjects individually and between-subjects individually). Results The latency for alpha ERD showed stable behaviour between two sessions, and the amplitude exhibited an increment (more negative) in the second session. Alpha ERD topography exhibited a high correlation score between sessions at the group level (r = 0.903, p<0.001). The mean value for within-subject correlations was 0.750 (with a range from 0.391 to 0.954). Regarding between-subject topography comparisons, some subjects showed a highly specific topography, whereas other subjects showed topographies that were more similar to those of other subjects. Conclusion ERD was mainly stable between the two sessions with the exception of amplitude, which exhibited an increment in the second session. Topography exhibits excellent reliability at the group level; however, it exhibits highly heterogeneous behaviour at the individual level. Considering that the P3 was previously evaluated for this group of subjects, a direct comparison of the correlation scores was possible, and it showed that the ERD component is less reliable in individual topography than in the ERP component (P3). PMID:29088307
Eden, Melissa M; Tompkins, James; Verheijde, Joseph L
2018-03-01
The purpose of this study was to establish the test-retest reliability of and relationships between various measures of physical function in a cohort of individuals in the early treatment stages for head and neck cancer (HNC). The Six-Minute Walk Test (6MWT), 10-Meter Walk Test (10MWT), 30-Second Sit to Stand (30STS), and Linear Analog Scale of Function (LASF) were administered to 42 participants with a diagnosis of HNC. Test-retest reliability and correlations between the measures are reported. The 6MWT, 10MWT, 30STS, and LASF demonstrate excellent test-retest reliability (ICC = 0.901-0.960). The 6MWT exhibits a moderate to good relationship with the 10MWT (r = 0.684, p < 0.001), whereas the relationship between the 30STS and the 6MWT (r = 0.407, p = 0.007) and 10MWT (r = 0.322, p = 0.038) is fair. The LASF does not correlate significantly with the 6MWT, 10MWT, or 30STS. The 6MWT, 10MWT, 30STS, and LASF are reliable measurement instruments for patients treated for HNC. The 6MWT, 10MWT, and 30STS are significantly correlated suggesting they may measure subconstructs of physical function. The LASF does not correlate significantly with the 6MWT, 10MWT and 30STS in this sample.
A field study of the accuracy and reliability of a biometric iris recognition system.
Latman, Neal S; Herb, Emily
2013-06-01
The iris of the eye appears to satisfy the criteria for a good anatomical characteristic for use in a biometric system. The purpose of this study was to evaluate a biometric iris recognition system: Mobile-Eyes™. The enrollment, verification, and identification applications were evaluated in a field study for accuracy and reliability using both irises of 277 subjects. Independent variables included a wide range of subject demographics, ambient light, and ambient temperature. A sub-set of 35 subjects had alcohol-induced nystagmus. There were 2710 identification and verification attempts, which resulted in 1,501,340 and 5540 iris comparisons respectively. In this study, the system successfully enrolled all subjects on the first attempt. All 277 subjects were successfully verified and identified on the first day of enrollment. None of the current or prior eye conditions prevented enrollment, verification, or identification. All 35 subjects with alcohol-induced nystagmus were successfully verified and identified. There were no false verifications or false identifications. Two conditions were identified that potentially could circumvent the use of iris recognitions systems in general. The Mobile-Eyes™ iris recognition system exhibited accurate and reliable enrollment, verification, and identification applications in this study. It may have special applications in subjects with nystagmus. Copyright © 2012 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.
Singh, Amika S; Vik, Froydis N; Chinapaw, Mai J M; Uijtdewilligen, Léonie; Verloigne, Maïté; Fernández-Alvira, Juan M; Stomfai, Sarolta; Manios, Yannis; Martens, Marloes; Brug, Johannes
2011-12-09
Insight in children's energy balance-related behaviours (EBRBs) and their determinants is important to inform obesity prevention research. Therefore, reliable and valid tools to measure these variables in large-scale population research are needed. To examine the test-retest reliability and construct validity of the child questionnaire used in the ENERGY-project, measuring EBRBs and their potential determinants among 10-12 year old children. We collected data among 10-12 year old children (n = 730 in the test-retest reliability study; n = 96 in the construct validity study) in six European countries, i.e. Belgium, Greece, Hungary, the Netherlands, Norway, and Spain. Test-retest reliability was assessed using the intra-class correlation coefficient (ICC) and percentage agreement comparing scores from two measurements, administered one week apart. To assess construct validity, the agreement between questionnaire responses and a subsequent face-to-face interview was assessed using ICC and percentage agreement. Of the 150 questionnaire items, 115 (77%) showed good to excellent test-retest reliability as indicated by ICCs > .60 or percentage agreement ≥ 75%. Test-retest reliability was moderate for 34 items (23%) and poor for one item. Construct validity appeared to be good to excellent for 70 (47%) of the 150 items, as indicated by ICCs > .60 or percentage agreement ≥ 75%. From the other 80 items, construct validity was moderate for 39 (26%) and poor for 41 items (27%). Our results demonstrate that the ENERGY-child questionnaire, assessing EBRBs of the child as well as personal, family, and school-environmental determinants related to these EBRBs, has good test-retest reliability and moderate to good construct validity for the large majority of items.
2011-01-01
Background Insight in children's energy balance-related behaviours (EBRBs) and their determinants is important to inform obesity prevention research. Therefore, reliable and valid tools to measure these variables in large-scale population research are needed. Objective To examine the test-retest reliability and construct validity of the child questionnaire used in the ENERGY-project, measuring EBRBs and their potential determinants among 10-12 year old children. Methods We collected data among 10-12 year old children (n = 730 in the test-retest reliability study; n = 96 in the construct validity study) in six European countries, i.e. Belgium, Greece, Hungary, the Netherlands, Norway, and Spain. Test-retest reliability was assessed using the intra-class correlation coefficient (ICC) and percentage agreement comparing scores from two measurements, administered one week apart. To assess construct validity, the agreement between questionnaire responses and a subsequent face-to-face interview was assessed using ICC and percentage agreement. Results Of the 150 questionnaire items, 115 (77%) showed good to excellent test-retest reliability as indicated by ICCs > .60 or percentage agreement ≥ 75%. Test-retest reliability was moderate for 34 items (23%) and poor for one item. Construct validity appeared to be good to excellent for 70 (47%) of the 150 items, as indicated by ICCs > .60 or percentage agreement ≥ 75%. From the other 80 items, construct validity was moderate for 39 (26%) and poor for 41 items (27%). Conclusions Our results demonstrate that the ENERGY-child questionnaire, assessing EBRBs of the child as well as personal, family, and school-environmental determinants related to these EBRBs, has good test-retest reliability and moderate to good construct validity for the large majority of items. PMID:22152048
Huber, Adam M; Feldman, Brian M; Rennebohm, Robert M; Hicks, Jeanne E; Lindsley, Carol B; Perez, Maria D; Zemel, Lawrence S; Wallace, Carol A; Ballinger, Susan H; Passo, Murray H; Reed, Ann M; Summers, Ronald M; White, Patience H; Katona, Ildy M; Miller, Frederick W; Lachenbruch, Peter A; Rider, Lisa G
2004-05-01
To examine the measurement characteristics of the Childhood Myositis Assessment Scale (CMAS) in children with juvenile idiopathic inflammatory myopathy (juvenile IIM), and to obtain preliminary data on the clinical significance of CMAS scores. One hundred eight children with juvenile IIM were evaluated on 2 occasions, 7-9 months apart, using various measures of physical function, strength, and disease activity. Interrater reliability, construct validity, and responsiveness of the CMAS were examined. The minimum clinically important difference (MID) and CMAS scores corresponding to various degrees of physical disability were estimated. The intraclass correlation coefficient for 26 patients assessed by 2 examiners was 0.89, indicating very good interrater reliability. The CMAS score correlated highly with the Childhood Health Assessment Questionnaire (C-HAQ) score and with findings on manual muscle testing (MMT) (r(s) = -0.73 and 0.73, respectively) and moderately with physician-assessed global disease activity and skin activity, parent-assessed global disease severity, and muscle magnetic resonance imaging (r(s) = -0.44 to -0.61), thereby demonstrating good construct validity. The standardized response mean was 0.81 (95% confidence interval 0.53, 1.09) in patients with at least 0.8 cm improvement on a 10-cm visual analog scale for physician-assessed global disease activity, indicating strong responsiveness. In bivariate regression models predicting physician-assessed global disease activity, MMT remained significant in models containing the CMAS (P = 0.03) while the C-HAQ did not (P = 0.4). Estimates of the MID ranged from 1.5 to 3.0 points on a 0-52-point scale. CMAS scores corresponding to no, mild, mild-to-moderate, and moderate physical disability, respectively, were 48, 45, 39, and 30. The CMAS exhibits good reliability, construct validity, and responsiveness, and is therefore a valid instrument for the assessment of physical function, muscle strength, and endurance in children with juvenile IIM. Preliminary data on MID and corresponding levels of disability should aid in the clinical interpretation of CMAS scores when assessing patients with juvenile IIM.
Spiekermann, Christoph; Rudack, Claudia; Stenner, Markus
2017-11-01
The outcome of aesthetic rhinoplasty is determined by the patient's subjective satisfaction with the nasal appearance which is difficult to assess. The Utrecht Questionnaire for Outcome Assessment in Aesthetic Rhinoplasty (OAR) is a brief and reliable instrument to assess the influence of the subjective nasal appearance on quality of life in patients undergoing aesthetic rhinoplasty. Preoperative application of this questionnaire reveals important aspects and possible disturbances of the body image which could be negative predictors concerning the result. On the other hand, it represents an appropriate tool to assess the postoperative outcome. The aim of this study was to determine the validity, reliability and responsiveness of the adapted German version of the OAR (D-OAR). The adaption of the OAR to German language was performed by a forward and backward translation process. Patients undergoing rhinoplasty were asked to complete the D-OAR preoperatively, 1, 3 and 12 months after procedure and healthy volunteers without any nasal complaints served as controls to test validity, reliability and responsiveness. An excellent internal consistency, a good test-retest reliability and good inter-item and item-total correlations demonstrated a good reliability of the D-OAR. The convincing validity of the adapted version was proven by an excellent discriminant and a sufficient content validity. Significant differences between pre- and postoperative D-OAR scores revealed a good responsiveness of the instrument. Hence, with a sufficient validity, reliability and sensitivity to changes, the D-OAR is a short and helpful instrument to assess the subjective perception of the nasal appearance in German patients.
A real-time posture monitoring method for rail vehicle bodies based on machine vision
NASA Astrophysics Data System (ADS)
Liu, Dongrun; Lu, Zhaijun; Cao, Tianpei; Li, Tian
2017-06-01
Monitoring vehicle operation conditions has become significantly important in modern high-speed railway systems. However, the operational impact of monitoring the roll angle of vehicle bodies has principally been limited to tilting trains, while few studies have focused on monitoring the running posture of vehicle bodies during operation. We propose a real-time posture monitoring method to fulfil real-time monitoring requirements, by taking rail surfaces and centrelines as detection references. In realising the proposed method, we built a mathematical computational model based on space coordinate transformations to calculate attitude angles of vehicles in operation and vertical and lateral vibration displacements of single measuring points. Moreover, comparison and verification of reliability between system and field results were conducted. Results show that monitoring of the roll angles of car bodies obtained through the system exhibit variation trends similar to those converted from the dynamic deflection of bogie secondary air springs. The monitoring results of two identical conditions were basically the same, highlighting repeatability and good monitoring accuracy. Therefore, our monitoring results were reliable in reflecting posture changes in running railway vehicles.
BSA-coated nanoparticles for improved SERS-based intracellular pH sensing.
Zheng, Xiao-Shan; Hu, Pei; Cui, Yan; Zong, Cheng; Feng, Jia-Min; Wang, Xin; Ren, Bin
2014-12-16
Local microenvironment pH sensing is one of the key parameters for the understanding of many biological processes. As a noninvasive and high sensitive technique, surface-enhanced Raman spectroscopy (SERS) has attracted considerable interest in the detection of the local pH of live cells. We herein develop a facile way to prepare Au-(4-MPy)-BSA (AMB) pH nanosensor. The 4-MPy (4-mercaptopyridine) was used as the pH sensing molecule. The modification of the nanoparticles with BSA not only provides a high sensitive response to pH changes ranging from pH 4.0 to 9.0 but also exhibits a high sensitivity and good biocompatibility, stability, and reliability in various solutions (including the solutions of high ionic strength or with complex composition such as the cell culture medium), both in the aggregation state or after long-term storage. The AMB pH nanosensor shows great advantages for reliable intracellular pH analysis and has been successfully used to monitor the pH distribution of live cells and can address the grand challenges in SERS-based pH sensing for practical biological applications.
Crespo, Alejandro C.; Dominguez, Jose M.; Barreiro, Anxo; Gómez-Gesteira, Moncho; Rogers, Benedict D.
2011-01-01
Smoothed Particle Hydrodynamics (SPH) is a numerical method commonly used in Computational Fluid Dynamics (CFD) to simulate complex free-surface flows. Simulations with this mesh-free particle method far exceed the capacity of a single processor. In this paper, as part of a dual-functioning code for either central processing units (CPUs) or Graphics Processor Units (GPUs), a parallelisation using GPUs is presented. The GPU parallelisation technique uses the Compute Unified Device Architecture (CUDA) of nVidia devices. Simulations with more than one million particles on a single GPU card exhibit speedups of up to two orders of magnitude over using a single-core CPU. It is demonstrated that the code achieves different speedups with different CUDA-enabled GPUs. The numerical behaviour of the SPH code is validated with a standard benchmark test case of dam break flow impacting on an obstacle where good agreement with the experimental results is observed. Both the achieved speed-ups and the quantitative agreement with experiments suggest that CUDA-based GPU programming can be used in SPH methods with efficiency and reliability. PMID:21695185
The Pareidolia Test: A Simple Neuropsychological Test Measuring Visual Hallucination-Like Illusions
Mamiya, Yasuyuki; Nishio, Yoshiyuki; Watanabe, Hiroyuki; Yokoi, Kayoko; Uchiyama, Makoto; Baba, Toru; Iizuka, Osamu; Kanno, Shigenori; Kamimura, Naoto; Kazui, Hiroaki; Hashimoto, Mamoru; Ikeda, Manabu; Takeshita, Chieko; Shimomura, Tatsuo; Mori, Etsuro
2016-01-01
Background Visual hallucinations are a core clinical feature of dementia with Lewy bodies (DLB), and this symptom is important in the differential diagnosis and prediction of treatment response. The pareidolia test is a tool that evokes visual hallucination-like illusions, and these illusions may be a surrogate marker of visual hallucinations in DLB. We created a simplified version of the pareidolia test and examined its validity and reliability to establish the clinical utility of this test. Methods The pareidolia test was administered to 52 patients with DLB, 52 patients with Alzheimer’s disease (AD) and 20 healthy controls (HCs). We assessed the test-retest/inter-rater reliability using the intra-class correlation coefficient (ICC) and the concurrent validity using the Neuropsychiatric Inventory (NPI) hallucinations score as a reference. A receiver operating characteristic (ROC) analysis was used to evaluate the sensitivity and specificity of the pareidolia test to differentiate DLB from AD and HCs. Results The pareidolia test required approximately 15 minutes to administer, exhibited good test-retest/inter-rater reliability (ICC of 0.82), and moderately correlated with the NPI hallucinations score (rs = 0.42). Using an optimal cut-off score set according to the ROC analysis, and the pareidolia test differentiated DLB from AD with a sensitivity of 81% and a specificity of 92%. Conclusions Our study suggests that the simplified version of the pareidolia test is a valid and reliable surrogate marker of visual hallucinations in DLB. PMID:27171377
Software Reliability Analysis of NASA Space Flight Software: A Practical Experience
Sukhwani, Harish; Alonso, Javier; Trivedi, Kishor S.; Mcginnis, Issac
2017-01-01
In this paper, we present the software reliability analysis of the flight software of a recently launched space mission. For our analysis, we use the defect reports collected during the flight software development. We find that this software was developed in multiple releases, each release spanning across all software life-cycle phases. We also find that the software releases were developed and tested for four different hardware platforms, spanning from off-the-shelf or emulation hardware to actual flight hardware. For releases that exhibit reliability growth or decay, we fit Software Reliability Growth Models (SRGM); otherwise we fit a distribution function. We find that most releases exhibit reliability growth, with Log-Logistic (NHPP) and S-Shaped (NHPP) as the best-fit SRGMs. For the releases that experience reliability decay, we investigate the causes for the same. We find that such releases were the first software releases to be tested on a new hardware platform, and hence they encountered major hardware integration issues. Also such releases seem to have been developed under time pressure in order to start testing on the new hardware platform sooner. Such releases exhibit poor reliability growth, and hence exhibit high predicted failure rate. Other problems include hardware specification changes and delivery delays from vendors. Thus, our analysis provides critical insights and inputs to the management to improve the software development process. As NASA has moved towards a product line engineering for its flight software development, software for future space missions will be developed in a similar manner and hence the analysis results for this mission can be considered as a baseline for future flight software missions. PMID:29278255
Software Reliability Analysis of NASA Space Flight Software: A Practical Experience.
Sukhwani, Harish; Alonso, Javier; Trivedi, Kishor S; Mcginnis, Issac
2016-01-01
In this paper, we present the software reliability analysis of the flight software of a recently launched space mission. For our analysis, we use the defect reports collected during the flight software development. We find that this software was developed in multiple releases, each release spanning across all software life-cycle phases. We also find that the software releases were developed and tested for four different hardware platforms, spanning from off-the-shelf or emulation hardware to actual flight hardware. For releases that exhibit reliability growth or decay, we fit Software Reliability Growth Models (SRGM); otherwise we fit a distribution function. We find that most releases exhibit reliability growth, with Log-Logistic (NHPP) and S-Shaped (NHPP) as the best-fit SRGMs. For the releases that experience reliability decay, we investigate the causes for the same. We find that such releases were the first software releases to be tested on a new hardware platform, and hence they encountered major hardware integration issues. Also such releases seem to have been developed under time pressure in order to start testing on the new hardware platform sooner. Such releases exhibit poor reliability growth, and hence exhibit high predicted failure rate. Other problems include hardware specification changes and delivery delays from vendors. Thus, our analysis provides critical insights and inputs to the management to improve the software development process. As NASA has moved towards a product line engineering for its flight software development, software for future space missions will be developed in a similar manner and hence the analysis results for this mission can be considered as a baseline for future flight software missions.
Multisite Reliability of Cognitive BOLD Data
Brown, Gregory G.; Mathalon, Daniel H.; Stern, Hal; Ford, Judith; Mueller, Bryon; Greve, Douglas N.; McCarthy, Gregory; Voyvodic, Jim; Glover, Gary; Diaz, Michele; Yetter, Elizabeth; Burak Ozyurt, I.; Jorgensen, Kasper W.; Wible, Cynthia G.; Turner, Jessica A.; Thompson, Wesley K.; Potkin, Steven G.
2010-01-01
Investigators perform multi-site functional magnetic resonance imaging studies to increase statistical power, to enhance generalizability, and to improve the likelihood of sampling relevant subgroups. Yet undesired site variation in imaging methods could off-set these potential advantages. We used variance components analysis to investigate sources of variation in the blood oxygen level dependent (BOLD) signal across four 3T magnets in voxelwise and region of interest (ROI) analyses. Eighteen participants traveled to four magnet sites to complete eight runs of a working memory task involving emotional or neutral distraction. Person variance was more than 10 times larger than site variance for five of six ROIs studied. Person-by-site interactions, however, contributed sizable unwanted variance to the total. Averaging over runs increased between-site reliability, with many voxels showing good to excellent between-site reliability when eight runs were averaged and regions of interest showing fair to good reliability. Between-site reliability depended on the specific functional contrast analyzed in addition to the number of runs averaged. Although median effect size was correlated with between-site reliability, dissociations were observed for many voxels. Brain regions where the pooled effect size was large but between-site reliability was poor were associated with reduced individual differences. Brain regions where the pooled effect size was small but between-site reliability was excellent were associated with a balance of participants who displayed consistently positive or consistently negative BOLD responses. Although between-site reliability of BOLD data can be good to excellent, acquiring highly reliable data requires robust activation paradigms, ongoing quality assurance, and careful experimental control. PMID:20932915
The development and validation of a custom built device for assessing frontal knee joint laxity.
Ismail, Shiek Abdullah; Simic, Milena; Clarke, Jillian L; Lopes, Thiago Jambo Alves; Pappas, Evangelos
2017-12-01
This study reports the development and validation of a quantitative technique of assessing frontal knee joint laxity through a custom built device named KLICP. The objectives of this study were to determine: (i) the intra- and inter-rater reliability and (ii) the validity of the device when compared to real time ultrasound. Twenty-five participants had their frontal knee joint laxity assessed by the KLICP, by manual varus/valgus tests and by ultrasound. Two raters independently assessed laxity manually by three repeated measurements, repeated at least 48h later. Results were validated by comparing them to the medial and lateral joint space opening measured by the ultrasound. Intraclass correlation coefficients and standard error of measurement reliability were calculated. Pearson's correlation coefficients were calculated to determine the correlation between the KLICP and the joint space. Intra-rater reliability (intra-session) for each rater was good on both sessions (0.91-0.98), intra-rater reliability (inter-sessions) was moderate to good (0.62-0.87), and inter-rater reliability (intra-session) was good (0.75-0.80). There is low agreement for intra-rater (inter-session) and for inter-rater (intra-session) reliability. The KLICP measurement has a significant positive fair to moderate correlation to the ultrasound measurement at the left (r: 0.61, p: 0.01) and right (r: 0.48, p: 0.02) knee in the valgus direction and at the left (r: 0.51, p: 0.01) and right (r: 0.39, p: 0.05) knee in the varus direction. There is low agreement between the KLICP and the RTU. Reliability and agreement was good only when measured for intra-rater, within session. Copyright © 2017 Elsevier B.V. All rights reserved.
Fully Printed Flexible and Stretchable Electronics
NASA Astrophysics Data System (ADS)
Zhang, Suoming
Through this thesis proposal, the author has demonstrated series of flexible or stretchable sensors including strain gauge, pressure sensors, display arrays, thin film transistors and photodetectors fabricated by a direct printing process. By adopting the novel serpentine configuration with conventional non-stretchable materials silver nanoparticles, the fully printed stretchable devices are successfully fabricated on elastomeric substrate with the demonstration of stretchable conductors that can maintain the electrical properties under strain and the strain gauge, which could be used to measure the strain in desired locations and also to monitor individual person's finger motion. And by investigating the intrinsic stretchable materials silver nanowires (AgNWs) with the conventional configuration, the fully printed stretchable conductors are achieved on various substrates including Si, glass, Polyimide, Polydimethylsiloxane (PDMS) and Very High Bond (VHB) tape with the illustration of the capacitive pressure sensor and stretchable electroluminescent displays. In addition, intrinsically stretchable thin-film transistors (TFTs) and integrated logic circuits are directly printed on elastomeric PDMS substrates. The printed devices utilize carbon nanotubes and a type of hybrid gate dielectric comprising PDMS and barium titanate (BaTiO3) nanoparticles. The BaTiO3/PDMS composite simultaneously provides high dielectric constant, superior stretchability, low leakage, as well as good printability and compatibility with the elastomeric substrate. Both TFTs and logic circuits can be stretched beyond 50% strain along either channel length or channel width directions for thousands of cycles while showing no significant degradation in electrical performance. Finally, by applying the SWNTs as the channel layer of the thin film transistor, we successfully fabricate the fully printed flexible photodetector which exhibits good electrical characteristics and the transistors exhibit good reliability under bending conditions owing to the ultrathin polyimide substrate as well as the superior mechanical flexibility of the gate dielectric and carbon nanotube network. Furthermore, we have demonstrated that by using two types of SWCNT samples with different optical absorption characteristics, the photoresponse exhibits unique wavelength selectivity, as manifested by the good correlation between the responsive wavelengths of the devices with the absorption peaks of the corresponding carbon nanotubes. All the proposed materials above together with the unique direct printing process may offer an entry into more sophisticated flexible or stretchable electronic systems with monolithically integrated sensors, actuators, and displays for real life applications.
Validity and Reliability of Farsi Version of Youth Sport Environment Questionnaire
Eshghi, Mohammad Ali; Kordi, Ramin; Memari, Amir Hossein; Ghaziasgar, Ahmad; Mansournia, Mohammad-Ali; Zamani Sani, Seyed Hojjat
2015-01-01
The Youth Sport Environment Questionnaire (YSEQ) had been developed from Group Environment Questionnaire, a well-known measure of team cohesion. The aim of this study was to adapt and examine the reliability and validity of the Farsi version of the YSEQ. This version was completed by 455 athletes aged 13–17 years. Results of confirmatory factor analysis indicated that two-factor solution showed a good fit to the data. The results also revealed that the Farsi YSEQ showed high internal consistency, test-retest reliability, and good concurrent validity. This study indicated that the Farsi version of the YSEQ is a valid and reliable measure to assess team cohesion in sport setting. PMID:26464900
International physical activity questionnaire: reliability and validity of the Turkish version.
Saglam, Melda; Arikan, Hulya; Savci, Sema; Inal-Ince, Deniz; Bosnak-Guclu, Meral; Karabulut, Erdem; Tokgozoglu, Lale
2010-08-01
Physical inactivity is a global problem which is related to many chronic health disorders. Physical activity scales which allow cross-cultural comparisons have been developed. The goal was to assess the reliability and validity of a Turkish version of the International Physical Activity Questionnaire (IPAQ). 1,097 university students (721 women, 376 men; ages 18-32) volunteered. Short and long forms of the IPAQ gave good agreement and comparable 1-wk. test-retest reliabilities. Caltrac accelerometer data were compared with IPAQ scores in 80 participants with good agreement for short and long forms. Turkish versions of the IPAQ short and long forms are reliable and valid in assessment of physical activity.
Mu, Boyuan; Li, Min
2018-06-11
In this study, tetradecanol/graphene aerogel form-stable composite phase change materials were prepared by physical absorption. Two kinds of graphene aerogels were prepared using vitamin C and ethylenediamine to enhance the thermal conductivity of tetradecanol and prevent its leakage during phase transition. The form-stable composite phase change material exhibited excellent thermal energy storage capacity. The latent heat of the tetradecanol/graphene aerogel composite phase change materials with 5 wt.% graphene aerogel was similar to the theoretical latent heat of pure tetradecanol. The thermal conductivity of the tetradecanol/graphene aerogel composite phase change material improved gradually as the graphene aerogel content increased. The prepared tetradecanol/graphene aerogel composite phase change materials exhibited good thermal reliability and thermal stability, and no chemical reaction occurred between tetradecanol and the graphene aerogel. In addition, the latent heat and thermal conductivity of the tetradecanol/ethylenediamine-graphene aerogel composites were higher than those of tetradecanol/vitamin C-graphene aerogel composites, and the flexible shape of the ethylenediamine-graphene aerogel is suitable for application of the tetradecanol/ethylenediamine-graphene aerogel composite.
Photoresponse in La0.9Hf0.1MnO3/0.05wt%Nb-doped SrTiO3 heteroepitaxial junctions
NASA Astrophysics Data System (ADS)
Qi, Yaping; Ni, Hao; Zheng, Ming; Zeng, Jiali; Jiang, Yucheng; Gao, Ju
2018-05-01
Excellent photo detectors need to have the rapid response and good repeatability from the requirement of industrial applications. In this paper, transport behavior and opto-response of heterostructures made with La0.9Hf0.1MnO3 and 0.05wt%Nb-doped SrTiO3 were investigated. The heterojunctions exhibited an excellent rectifying feature with very low leakage in a broad temperature region (from 40 to 300 K). These thin films presented persistent and stable photovoltages upon light illumination. Rapid shift between small and large voltages corresponding to "light OFF" and "light ON" states, respectively, was observed, demonstrating reliable photo detection behavior. A semiconductor laser with a wavelength of 650 nm was used as the light source. It is also noted that the observed photovoltages are strongly determined by light intensity. The injection of photoexcited charge carriers (electrons) could be responsible for the appearance of the observed opto-response. Such manipulative features by light irradiation exhibit great potential for light detectors for visible light.
Chopade, Sujay A; Anderson, Evan L; Schmidt, Peter W; Lodge, Timothy P; Hillmyer, Marc A; Bühlmann, Philippe
2017-10-27
Interfaces of ionic liquids and aqueous solutions exhibit stable electrical potentials over a wide range of aqueous electrolyte concentrations. This makes ionic liquids suitable as bridge materials that separate in electroanalytical measurements the reference electrode from samples with low and/or unknown ionic strengths. However, methods for the preparation of ionic liquid-based reference electrodes have not been explored widely. We have designed a convenient and reliable synthesis of ionic liquid-based reference electrodes by polymerization-induced microphase separation. This technique allows for a facile, single-pot synthesis of ready-to-use reference electrodes that incorporate ion conducting nanochannels filled with either 1-octyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide or 1-dodecyl-3-methylimidazolium bis(trifluoromethyl sulfonyl)imide as ionic liquid, supported by a mechanically robust cross-linked polystyrene phase. This synthesis procedure allows for the straightforward design of various reference electrode geometries. These reference electrodes exhibit a low resistance as well as good reference potential stability and reproducibility when immersed into aqueous solutions varying from deionized, purified water to 100 mM KCl, while requiring no correction for liquid junction potentials.
Feng, Dawei; Lei, Ting; Lukatskaya, Maria R.; ...
2018-01-01
For miniaturized capacitive energy storage, volumetric and areal capacitances are more important metrics than gravimetric ones because of the constraints imposed by device volume and chip area. Typically used in commercial supercapacitors, porous carbons, although they provide a stable and reliable performance, lack volumetric performance because of their inherently low density and moderate capacitances. In this paper, we report a high-performing electrode based on conductive hexaaminobenzene (HAB)-derived two-dimensional metal-organic frameworks (MOFs). In addition to possessing a high packing density and hierarchical porous structure, these MOFs also exhibit excellent chemical stability in both acidic and basic aqueous solutions, which is inmore » sharp contrast to conventional MOFs. Submillimetre-thick pellets of HAB MOFs showed high volumetric capacitances up to 760 F cm -3 and high areal capacitances over 20 F cm -2. Furthermore, the HAB MOF electrodes exhibited highly reversible redox behaviours and good cycling stability with a capacitance retention of 90% after 12,000 cycles. In conclusion, these promising results demonstrate the potential of using redox-active conductive MOFs in energy-storage applications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feng, Dawei; Lei, Ting; Lukatskaya, Maria R.
For miniaturized capacitive energy storage, volumetric and areal capacitances are more important metrics than gravimetric ones because of the constraints imposed by device volume and chip area. Typically used in commercial supercapacitors, porous carbons, although they provide a stable and reliable performance, lack volumetric performance because of their inherently low density and moderate capacitances. In this paper, we report a high-performing electrode based on conductive hexaaminobenzene (HAB)-derived two-dimensional metal-organic frameworks (MOFs). In addition to possessing a high packing density and hierarchical porous structure, these MOFs also exhibit excellent chemical stability in both acidic and basic aqueous solutions, which is inmore » sharp contrast to conventional MOFs. Submillimetre-thick pellets of HAB MOFs showed high volumetric capacitances up to 760 F cm -3 and high areal capacitances over 20 F cm -2. Furthermore, the HAB MOF electrodes exhibited highly reversible redox behaviours and good cycling stability with a capacitance retention of 90% after 12,000 cycles. In conclusion, these promising results demonstrate the potential of using redox-active conductive MOFs in energy-storage applications.« less
NASA Astrophysics Data System (ADS)
Feng, Dawei; Lei, Ting; Lukatskaya, Maria R.; Park, Jihye; Huang, Zhehao; Lee, Minah; Shaw, Leo; Chen, Shucheng; Yakovenko, Andrey A.; Kulkarni, Ambarish; Xiao, Jianping; Fredrickson, Kurt; Tok, Jeffrey B.; Zou, Xiaodong; Cui, Yi; Bao, Zhenan
2018-01-01
For miniaturized capacitive energy storage, volumetric and areal capacitances are more important metrics than gravimetric ones because of the constraints imposed by device volume and chip area. Typically used in commercial supercapacitors, porous carbons, although they provide a stable and reliable performance, lack volumetric performance because of their inherently low density and moderate capacitances. Here we report a high-performing electrode based on conductive hexaaminobenzene (HAB)-derived two-dimensional metal-organic frameworks (MOFs). In addition to possessing a high packing density and hierarchical porous structure, these MOFs also exhibit excellent chemical stability in both acidic and basic aqueous solutions, which is in sharp contrast to conventional MOFs. Submillimetre-thick pellets of HAB MOFs showed high volumetric capacitances up to 760 F cm-3 and high areal capacitances over 20 F cm-2. Furthermore, the HAB MOF electrodes exhibited highly reversible redox behaviours and good cycling stability with a capacitance retention of 90% after 12,000 cycles. These promising results demonstrate the potential of using redox-active conductive MOFs in energy-storage applications.
van der Meulen, Ineke; van de Sandt-Koenderman, W Mieke E; Duivenvoorden, Hugo J; Ribbers, Gerard M
2010-01-01
This study explores the psychometric qualities of the Scenario Test, a new test to assess daily-life communication in severe aphasia. The test is innovative in that it: (1) examines the effectiveness of verbal and non-verbal communication; and (2) assesses patients' communication in an interactive setting, with a supportive communication partner. To determine the reliability, validity, and sensitivity to change of the Scenario Test and discuss its clinical value. The Scenario Test was administered to 122 persons with aphasia after stroke and to 25 non-aphasic controls. Analyses were performed for the entire group of persons with aphasia, as well as for a subgroup of persons unable to communicate verbally (n = 43). Reliability (internal consistency, test-retest reliability, inter-judge, and intra-judge reliability) and validity (internal validity, convergent validity, known-groups validity) and sensitivity to change were examined using standard psychometric methods. The Scenario Test showed high levels of reliability. Internal consistency (Cronbach's alpha = 0.96; item-rest correlations = 0.58-0.82) and test-retest reliability (ICC = 0.98) were high. Agreement between judges in total scores was good, as indicated by the high inter- and intra-judge reliability (ICC = 0.86-1.00). Agreement in scores on the individual items was also good (square-weighted kappa values 0.61-0.92). The test demonstrated good levels of validity. A principal component analysis for categorical data identified two dimensions, interpreted as general communication and communicative creativity. Correlations with three other instruments measuring communication in aphasia, that is, Spontaneous Speech interview from the Aachen Aphasia Test (AAT), Amsterdam-Nijmegen Everyday Language Test (ANELT), and Communicative Effectiveness Index (CETI), were moderate to strong (0.50-0.85) suggesting good convergent validity. Group differences were observed between persons with aphasia and non-aphasic controls, as well as between persons with aphasia unable to use speech to convey information and those able to communicate verbally; this indicates good known-groups validity. The test was sensitive to changes in performance, measured over a period of 6 months. The data support the reliability and validity of the Scenario Test as an instrument for examining daily-life communication in aphasia. The test focuses on multimodal communication; its psychometric qualities enable future studies on the effect of Alternative and Augmentative Communication (AAC) training in aphasia.
Gustafsson, Peik; Svedin, Carl Göran; Ericsson, Ingegerd; Lindén, Christian; Karlsson, Magnus K; Thernlund, Gunilla
2010-04-01
To study the value and reliability of an examination of neurological soft-signs, often used in Sweden, in the assessment of children with attention-deficit-hyperactivity disorder (ADHD), by examining children with and without ADHD, as diagnosed by an experienced clinician using the DSM-III-R. We have examined interrater reliability (26 males, nine females; age range 5y 6mo-11y), internal consistency (94 males, 43 females; age range 5y 6mo-11y), test-retest reliability (12 males, eight females; age range 6-9y), and validity (79 males, 33 females; age range 5y 6mo-9y). The sum of the scores for the items on the examination had good interrater reliability (intraclass correlation [ICC] 0.95) and acceptable internal consistency (Cronbach's alpha 0.76). The test-retest study also showed good reliability (ICC 0.91). There were modest associations between the examination and the assessment of motor function made by the physical education teacher (ICC 0.37) as well as from the parents' description (ICC 0.39). The examination of neurological soft-signs had a sensitivity of 0.80 and a specificity of 0.76 in predicting motor problems as evaluated by the physical education teacher. The reliability and validity of this examination seem to be good and can be recommended for clinical practice and research.
Mani, Suresh; Sharma, Shobha; Omar, Baharudin; Paungmali, Aatit; Joseph, Leonard
2017-04-01
Purpose The purpose of this review is to systematically explore and summarise the validity and reliability of telerehabilitation (TR)-based physiotherapy assessment for musculoskeletal disorders. Method A comprehensive systematic literature review was conducted using a number of electronic databases: PubMed, EMBASE, PsycINFO, Cochrane Library and CINAHL, published between January 2000 and May 2015. The studies examined the validity, inter- and intra-rater reliabilities of TR-based physiotherapy assessment for musculoskeletal conditions were included. Two independent reviewers used the Quality Appraisal Tool for studies of diagnostic Reliability (QAREL) and the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool to assess the methodological quality of reliability and validity studies respectively. Results A total of 898 hits were achieved, of which 11 articles based on inclusion criteria were reviewed. Nine studies explored the concurrent validity, inter- and intra-rater reliabilities, while two studies examined only the concurrent validity. Reviewed studies were moderate to good in methodological quality. The physiotherapy assessments such as pain, swelling, range of motion, muscle strength, balance, gait and functional assessment demonstrated good concurrent validity. However, the reported concurrent validity of lumbar spine posture, special orthopaedic tests, neurodynamic tests and scar assessments ranged from low to moderate. Conclusion TR-based physiotherapy assessment was technically feasible with overall good concurrent validity and excellent reliability, except for lumbar spine posture, orthopaedic special tests, neurodynamic testa and scar assessment.
ERIC Educational Resources Information Center
Lopata, Christopher; Rodgers, Jonathan D.; Donnelly, James P.; Thomeer, Marcus L.; McDonald, Christin A.; Volker, Martin A.
2017-01-01
This study examined the reliability and criterion-related validity of parent ratings on the Adapted Skillstreaming Checklist (ASC) for a sample of 275 high-functioning children, ages 6-12 years, with ASD. Internal consistency for the total sample was 0.92. For two subsamples, test-retest reliability was very good at the 6-week and good at the…
Non-enzymatic detection of glucose using poly(azure A)-nickel modified glassy carbon electrode.
Liu, Tong; Luo, Yiqun; Zhu, Jiaming; Kong, Liyan; Wang, Wen; Tan, Liang
2016-08-15
A simple, sensitive and selective non-enzymatic glucose sensor was constructed in this paper. The poly(azure A)-nickel modified glassy carbon electrode was successfully fabricated by the electropolymerization of azure A and the adsorption of Ni(2+). The Ni modified electrode, which was characterized by scanning electron microscope, cyclic voltammetry, electrochemical impedance spectra and X-ray photoelectron spectroscopy measurements, respectively, displayed well-defined current responses of the Ni(III)/Ni(II) couple and showed a good activity for electrocatalytic oxidation of glucose in alkaline medium. Under the optimized conditions, the developed sensor exhibited a broad linear calibration range of 5 μM-12mM for quantification of glucose and a low detection limit of 0.64μM (3σ). The excellent analytical performance including simple structure, fast response time, good anti-interference ability, satisfying stability and reliable reproducibility were also found from the proposed amperometric sensor. The results were satisfactory for the determination of glucose in human serum samples as comparison to those from a local hospital. Copyright © 2016 Elsevier B.V. All rights reserved.
Chen, Ke; Chai, Zhigang; Li, Cong; Shi, Liurong; Liu, Mengxi; Xie, Qin; Zhang, Yanfeng; Xu, Dongsheng; Manivannan, Ayyakkannu; Liu, Zhongfan
2016-03-22
Mass production of high-quality graphene flakes is important for commercial applications. Graphene microsheets have been produced on an industrial scale by chemical and liquid-phase exfoliation of graphite. However, strong-interaction-induced interlayer aggregation usually leads to the degradation of their intrinsic properties. Moreover, the crystallinity or layer-thickness controllability is not so perfect to fulfill the requirement for advanced technologies. Herein, we report a quartz-powder-derived chemical vapor deposition growth of three-dimensional (3D) high-quality graphene flakes and demonstrate the fabrication and application of graphene/g-C3N4 composites. The graphene flakes obtained after the removal of growth substrates exhibit the 3D curved microstructure, controllable layer thickness, good crystallinity, as well as weak interlayer interactions suitable for preventing the interlayer stacking. Benefiting from this, we achieved the direct synthesis of g-C3N4 on purified graphene flakes to form the uniform graphene/g-C3N4 composite, which provides efficient electron transfer interfaces to boost its catalytic oxidation activity of cycloalkane with relatively high yield, good selectivity, and reliable stability.
Pilot testing of SHRP 2 reliability data and analytical products: Washington.
DOT National Transportation Integrated Search
2014-07-30
The second Strategic Highway Research Program (SHRP 2) addresses the challenges of moving people and goods efficiently and safely on the nations highways. In its Reliability focus area, the research emphasizes improving the reliability of highway ...
FPGA implementation of advanced FEC schemes for intelligent aggregation networks
NASA Astrophysics Data System (ADS)
Zou, Ding; Djordjevic, Ivan B.
2016-02-01
In state-of-the-art fiber-optics communication systems the fixed forward error correction (FEC) and constellation size are employed. While it is important to closely approach the Shannon limit by using turbo product codes (TPC) and low-density parity-check (LDPC) codes with soft-decision decoding (SDD) algorithm; rate-adaptive techniques, which enable increased information rates over short links and reliable transmission over long links, are likely to become more important with ever-increasing network traffic demands. In this invited paper, we describe a rate adaptive non-binary LDPC coding technique, and demonstrate its flexibility and good performance exhibiting no error floor at BER down to 10-15 in entire code rate range, by FPGA-based emulation, making it a viable solution in the next-generation high-speed intelligent aggregation networks.
Self-catalytic VLS growth one dimensional layered GaSe nanobelts for high performance photodetectors
NASA Astrophysics Data System (ADS)
Tang, Luping; Zhao, Zixiang; Yuan, Shuangping; Yang, Tiefeng; Zhou, Bingxin; Zhou, Hong
2018-07-01
Layered GaSe is an important binary semiconductor because of its anisotropic crystallography characteristics, wide band gap and attractive optical and electrical properties. Here, we report the self-catalytic growth of GaSe nanobelts via a simple chemical vapor deposition method. The quality of the as-grown nanobelts have been confirmed by transmission electron microscope and photoluminescence spectra. The field-effect transistors based on these individual GaSe nanobelts have been fabricated and show p-type semiconducting behaviors and on-off ratio of 106. The GaSe nanobelts not only show good responsivity of 164.4 A W-1, but also exhibit excellent stability and reliability, which are superior to their bulk counterparts. These results make GaSe nanobelt a promising optoelectronic material in integrated electronic/optoelectronic devices.
Conductance switching in Ag(2)S devices fabricated by in situ sulfurization.
Morales-Masis, M; van der Molen, S J; Fu, W T; Hesselberth, M B; van Ruitenbeek, J M
2009-03-04
We report a simple and reproducible method to fabricate switchable Ag(2)S devices. The alpha-Ag(2)S thin films are produced by a sulfurization process after silver deposition on an Si substrate. Structure and composition of the Ag(2)S are characterized using XRD and RBS. Our samples show semiconductor behaviour at low bias voltages, whereas they exhibit reproducible bipolar resistance switching at higher bias voltages. The transition between both types of behaviour is observed by hysteresis in the I-V curves, indicating decomposition of the Ag(2)S, increasing the Ag(+) ion mobility. The as-fabricated Ag(2)S samples are a good candidate for future solid state memory devices, as they show reproducible memory resistive properties and they are fabricated by an accessible and reliable method.
Pocket Handbook on Reliability
1975-09-01
exponencial distributions Weibull distribution, -xtimating reliability, confidence intervals, relia- bility growth, 0. P- curves, Bayesian analysis. 20 A S...introduction for those not familiar with reliability and a good refresher for those who are currently working in the area. LEWIS NERI, CHIEF...includes one or both of the following objectives: a) prediction of the current system reliability, b) projection on the system reliability for someI future
Liu, Ying-Buh; Yang, Stephen S; Hsieh, Cheng-Hsing; Lin, Chia-Da; Chang, Shang-Jen
2014-05-01
To evaluate the inter-observer, intra-observer and intra-individual reliability of uroflowmetry and post-void residual urine (PVR) tests in adult men. Healthy volunteers aged over 40 years were enrolled. Every participant underwent two sets of uroflowmetry and PVR tests with a 2-week interval between the tests. The uroflowmetry tests were interpreted by four urologists independently. Uroflowmetry curves were classified as bell-shaped, bell-shaped with tail, obstructive, restrictive, staccato, interrupted and tower-shaped and scored from 1 (highly abnormal) to 5 (absolutely normal). The agreements between the observers, interpretations and tests within individuals were analyzed using kappa statistics and intraclass correlation coefficients. Generalizability theory with decision analysis was used to determine how many observers, tests, and interpretations were needed to obtain an acceptable reliability (> 0.80). Of 108 volunteers, we randomly selected the uroflowmetry results from 25 participants for the evaluation of reliability. The mean age of the studied adults was 55.3 years. The intra-individual and intra-observer reliability on uroflowmetry tests ranged from good to very good. However, the inter-observer reliability on normalcy and specific type of flow pattern were relatively lower. In generalizability theory, three observers were needed to obtain an acceptable reliability on normalcy of uroflow pattern if the patient underwent uroflowmetry tests twice with one observation. The intra-individual and intra-observer reliability on uroflowmetry tests were good while the inter-observer reliability was relatively lower. To improve inter-observer reliability, the definition of uroflowmetry should be clarified by the International Continence Society. © 2013 Wiley Publishing Asia Pty Ltd.
Siahaan, Laura A; Syam, Ari F; Simadibrata, Marcellus; Setiati, Siti
2017-01-01
to obtain a valid and reliable GERD-QOL questionnaire for Indonesian application. at the initial stage, the GERD-QOL questionnaire was first translated into Indonesian language and the translated questionnaire was subsequently translated back into the original language (back-to-back translation). The results were evaluated by the researcher team and therefore, an Indonesian version of GERD-QOL questionnaire was developed. Ninety-one patients who had been clinically diagnosed with GERD based on the Montreal criteria were interviewed using the Indonesian version of GERD-QOL questionnaire and the SF 36 questionnaire. The validity was evaluated using a method of construct validity and external validity, and reliability can be tested by the method of internal consistency and test retest. the Indonesian version of GERD-QOL questionnaire had a good internal consistency reliability with a Cronbach Alpha of 0.687-0.842 and a good test retest reliability with an intra-class correlation coefficient of 0.756-0.936; p<0.05). The questionnaire had also been demonstrated to have a good validity with a proven high correlation to each question of SF-36 (p<0.05). the Indonesian version of GERD-QOL questionnaire has been proven valid and reliable to evaluate the quality of life of GERD patients.
On the reliability of seasonal climate forecasts
Weisheimer, A.; Palmer, T. N.
2014-01-01
Seasonal climate forecasts are being used increasingly across a range of application sectors. A recent UK governmental report asked: how good are seasonal forecasts on a scale of 1–5 (where 5 is very good), and how good can we expect them to be in 30 years time? Seasonal forecasts are made from ensembles of integrations of numerical models of climate. We argue that ‘goodness’ should be assessed first and foremost in terms of the probabilistic reliability of these ensemble-based forecasts; reliable inputs are essential for any forecast-based decision-making. We propose that a ‘5’ should be reserved for systems that are not only reliable overall, but where, in particular, small ensemble spread is a reliable indicator of low ensemble forecast error. We study the reliability of regional temperature and precipitation forecasts of the current operational seasonal forecast system of the European Centre for Medium-Range Weather Forecasts, universally regarded as one of the world-leading operational institutes producing seasonal climate forecasts. A wide range of ‘goodness’ rankings, depending on region and variable (with summer forecasts of rainfall over Northern Europe performing exceptionally poorly) is found. Finally, we discuss the prospects of reaching ‘5’ across all regions and variables in 30 years time. PMID:24789559
The development of an instrument to match individuals with disabilities and service animals.
Zapf, S A; Rough, R B
There has been an increase in the use of service animals assisting persons with disabilities in the past decade. However many of the service dog agencies do not utilize an assessment that is designed to match the person to the animal in the rehabilitation and psycho-social domains. The purpose of this study was to develop the Service Animal Adaptive Intervention Assessment (SAAIA) and to measure the content validity, inter-rater reliability and clinical utility of the assessment. Two subject groups were used. Subject group one had 43 subjects who measured the content validity and clinical utility of the SAAIA Survey. Subject group two had 12 subjects who measured the inter-rater reliability by completing the SAAIA using information obtained through a video-taped client case scenario. Content validity results indicated a good to high percentage of agreement and a fair percentage of agreement for clinical utility. Inter-rater reliability results indicate good to high agreement on six of the eight variables of the SAAIA. However, the Kappa score indicates low inter-rater reliability. Results indicate the SAAIA has good content validity and inter-rater reliability and fair clinical utility based on percent agreement. However, further research is needed on the reliability of the SAAIA.
Chang, Wen-Dien; Chang, Wan-Yi; Lee, Chia-Lun; Feng, Chi-Yen
2013-10-01
[Purpose] Balance is an integral part of human ability. The smart balance master system (SBM) is a balance test instrument with good reliability and validity, but it is expensive. Therefore, we modified a Wii Fit balance board, which is a convenient balance assessment tool, and analyzed its reliability and validity. [Subjects and Methods] We recruited 20 healthy young adults and 20 elderly people, and administered 3 balance tests. The correlation coefficient and intraclass correlation of both instruments were analyzed. [Results] There were no statistically significant differences in the 3 tests between the Wii Fit balance board and the SBM. The Wii Fit balance board had a good intraclass correlation (0.86-0.99) for the elderly people and positive correlations (r = 0.58-0.86) with the SBM. [Conclusions] The Wii Fit balance board is a balance assessment tool with good reliability and high validity for elderly people, and we recommend it as an alternative tool for assessing balance ability.
Urdu translation of the Hamilton Rating Scale for Depression: Results of a validation study
Hashmi, Ali M.; Naz, Shahana; Asif, Aftab; Khawaja, Imran S.
2016-01-01
Objective: To develop a standardized validated version of the Hamilton Rating Scale for Depression (HAM-D) in Urdu. Methods: After translation of the HAM-D into the Urdu language following standard guidelines, the final Urdu version (HAM-D-U) was administered to 160 depressed outpatients. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation between HAM-D-U scores at baseline and after a 2-week interval was evaluated for test-retest reliability. Moreover, scores of two clinicians on HAM-D-U were compared for inter-rater reliability. For establishing concurrent validity, scores of HAM-D-U and BDI-U were compared by using Spearman correlation coefficient. The study was conducted at Mayo Hospital, Lahore, from May to December 2014. Results: The Cronbach alpha for HAM-D-U was 0.71. Composite scores for HAM-D-U at baseline and after a 2-week interval were also highly correlated with each other (Spearman correlation coefficient 0.83, p-value < 0.01) indicating good test-retest reliability. Composite scores for HAM-D-U and BDI-U were positively correlated with each other (Spearman correlation coefficient 0.85, p < 0.01) indicating good concurrent validity. Scores of two clinicians for HAM-D-U were also positively correlated (Spearman correlation coefficient 0.82, p-value < 0.01) indicated good inter-rater reliability. Conclusion: The HAM-D-U is a valid and reliable instrument for the assessment of Depression. It shows good inter-rater and test-retest reliability. The HAM-D-U can be a tool either for clinical management or research. PMID:28083049
Urdu translation of the Hamilton Rating Scale for Depression: Results of a validation study.
Hashmi, Ali M; Naz, Shahana; Asif, Aftab; Khawaja, Imran S
2016-01-01
To develop a standardized validated version of the Hamilton Rating Scale for Depression (HAM-D) in Urdu. After translation of the HAM-D into the Urdu language following standard guidelines, the final Urdu version (HAM-D-U) was administered to 160 depressed outpatients. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation between HAM-D-U scores at baseline and after a 2-week interval was evaluated for test-retest reliability. Moreover, scores of two clinicians on HAM-D-U were compared for inter-rater reliability. For establishing concurrent validity, scores of HAM-D-U and BDI-U were compared by using Spearman correlation coefficient. The study was conducted at Mayo Hospital, Lahore, from May to December 2014. The Cronbach alpha for HAM-D-U was 0.71. Composite scores for HAM-D-U at baseline and after a 2-week interval were also highly correlated with each other (Spearman correlation coefficient 0.83, p-value < 0.01) indicating good test-retest reliability. Composite scores for HAM-D-U and BDI-U were positively correlated with each other (Spearman correlation coefficient 0.85, p < 0.01) indicating good concurrent validity. Scores of two clinicians for HAM-D-U were also positively correlated (Spearman correlation coefficient 0.82, p-value < 0.01) indicated good inter-rater reliability. The HAM-D-U is a valid and reliable instrument for the assessment of Depression. It shows good inter-rater and test-retest reliability. The HAM-D-U can be a tool either for clinical management or research.
A Novel Solution-Technique Applied to a Novel WAAS Architecture
NASA Technical Reports Server (NTRS)
Bavuso, J.
1998-01-01
The Federal Aviation Administration has embarked on an historic task of modernizing and significantly improving the national air transportation system. One system that uses the Global Positioning System (GPS) to determine aircraft navigational information is called the Wide Area Augmentation System (WAAS). This paper describes a reliability assessment of one candidate system architecture for the WAAS. A unique aspect of this study regards the modeling and solution of a candidate system that allows a novel cold sparing scheme. The cold spare is a WAAS communications satellite that is fabricated and launched after a predetermined number of orbiting satellite failures have occurred and after some stochastic fabrication time transpires. Because these satellites are complex systems with redundant components, they exhibit an increasing failure rate with a Weibull time to failure distribution. Moreover, the cold spare satellite build-time is Weibull and upon launch is considered to be a good-as-new system with an increasing failure rate and a Weibull time to failure distribution as well. The reliability model for this system is non-Markovian because three distinct system clocks are required: the time to failure of the orbiting satellites, the build time for the cold spare, and the time to failure for the launched spare satellite. A powerful dynamic fault tree modeling notation and Monte Carlo simulation technique with importance sampling are shown to arrive at a reliability prediction for a 10 year mission.
Praxedes, Marcus Fernando da Silva; de Abreu, Mauro Henrique Nogueira Guimarães; Paiva, Saul Martins; Mambrini, Juliana Vaz de Melo; Marcolino, Milena Soriano; Martins, Maria Auxiliadora Parreiras
2016-06-24
The aim of this study was to evaluate the psychometric properties of the Brazilian version of the Oral Anticoagulation Knowledge (OAK) Test. This study, conducted in an anticoagulation clinic, included 201 Brazilian participants aged over 18 years, who had been using warfarin for more than two months. The reliability of the instrument was evaluated by assessing internal consistency (Kuder-Richardson coefficient) and reproducibility (test-retest reliability). The validity was evaluated by hypothesizing that there would be a positive correlation of moderate to strong intensity between the correctness levels of the OAK Test and time within therapeutic range (TTR) values, which is a measure used to evaluate the quality of oral anticoagulation. The instrument exhibited good psychometric properties. The total a Kuder-Richardson coefficient value was 0.818 and intraclass correlation coefficient was 0.967. The validity revealed a strong positive correlation between the values of the level of knowledge, as measured by the OAK Test and the TTR values (rs = 0.780). The instrument proved to be a reliable and valid tool for evaluating the knowledge of Brazilian patients on oral anticoagulation therapy with warfarin. This instrument may be incorporated into the practice of health care for substantiating the structuring of educational activities to ensure the improvement of knowledge about the use of warfarin, thereby increasing the effectiveness and safety of treatment.
Reliable motion detection of small targets in video with low signal-to-clutter ratios
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nichols, S.A.; Naylor, R.B.
1995-07-01
Studies show that vigilance decreases rapidly after several minutes when human operators are required to search live video for infrequent intrusion detections. Therefore, there is a need for systems which can automatically detect targets in live video and reserve the operator`s attention for assessment only. Thus far, automated systems have not simultaneously provided adequate detection sensitivity, false alarm suppression, and ease of setup when used in external, unconstrained environments. This unsatisfactory performance can be exacerbated by poor video imagery with low contrast, high noise, dynamic clutter, image misregistration, and/or the presence of small, slow, or erratically moving targets. This papermore » describes a highly adaptive video motion detection and tracking algorithm which has been developed as part of Sandia`s Advanced Exterior Sensor (AES) program. The AES is a wide-area detection and assessment system for use in unconstrained exterior security applications. The AES detection and tracking algorithm provides good performance under stressing data and environmental conditions. Features of the algorithm include: reliable detection with negligible false alarm rate of variable velocity targets having low signal-to-clutter ratios; reliable tracking of targets that exhibit motion that is non-inertial, i.e., varies in direction and velocity; automatic adaptation to both infrared and visible imagery with variable quality; and suppression of false alarms caused by sensor flaws and/or cutouts.« less
Tadakamadla, Jyothi; Kumar, Santhosh; Lalloo, Ratilal; Johnson, Newell W
2017-03-01
The aim of this study was to develop and evaluate the validity and reliability of a quality-of-life (QoL) questionnaire for patients with oral potentially malignant disorders (OPMDs). For item generation, 15 personal interviews and three focus group discussions were conducted with OPMD patients existing QoL questionnaires were reviewed, and inputs from specialist clinicians (n = 10) were considered. Data collected from patients were analyzed by using NVivo. This led to the identification of themes, item writing, scaling, item reduction, formatting, and pretesting of the newly developed questionnaire. The validity and reliability of the questionnaire were assessed in a separate sample of 300 patients (150 each of patients with OPMD and healthy individuals). Sixty items were generated from the qualitative data and by reviewing existing questionnaires. After item reduction, the final questionnaire comprised 20 questions, which could be categorized under four domains. Exploratory factor analysis revealed a four-factor structure conforming to the four domains. The OPMD QoL questionnaire exhibited good discriminant and convergent validity, with OPMD patients reporting poorer QoL compared with healthy individuals and correlating significantly with existing questionnaires designed for similar purposes respectively. Our OPMD QoL questionnaire was found to be valid and reliable. We recommend that it be applied in epidemiologic and treatment studies of these disorders. Copyright © 2016 Elsevier Inc. All rights reserved.
Cutolo, Maurizio; Vanhaecke, Amber; Ruaro, Barbara; Deschepper, Ellen; Ickinger, Claudia; Melsens, Karin; Piette, Yves; Trombetta, Amelia Chiara; De Keyser, Filip; Smith, Vanessa
2018-06-06
A reliable tool to evaluate flow is paramount in systemic sclerosis (SSc). We describe herein on the one hand a systematic literature review on the reliability of laser speckle contrast analysis (LASCA) to measure the peripheral blood perfusion (PBP) in SSc and perform an additional pilot study, investigating the intra- and inter-rater reliability of LASCA. A systematic search was performed in 3 electronic databases, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. In the pilot study, 30 SSc patients and 30 healthy subjects (HS) underwent LASCA assessment. Intra-rater reliability was assessed by having a first anchor rater performing the measurements at 2 time-points and inter-rater reliability by having the anchor rater and a team of second raters performing the measurements in 15 SSc and 30 HS. The measurements were repeated with a second anchor rater in the other 15 SSc patients, as external validation. Only 1 of the 14 records of interest identified through the systematic search was included in the final analysis. In the additional pilot study: intra-class correlation coefficient (ICC) for intra-rater reliability of the first anchor rater was 0.95 in SSc and 0.93 in HS, the ICC for inter-rater reliability was 0.97 in SSc and 0.93 in HS. Intra- and inter-rater reliability of the second anchor rater was 0.78 and 0.87. The identified literature regarding the reliability of LASCA measurements reports good to excellent inter-rater agreement. This very pilot study could confirm the reliability of LASCA measurements with good to excellent inter-rater agreement and found additionally good to excellent intra-rater reliability. Furthermore, similar results were found in the external validation. Copyright © 2018. Published by Elsevier B.V.
Chuang, I-Ching; Lin, Keh-Chung; Wu, Ching-Yi; Hsieh, Yu-Wei; Liu, Chien-Ting; Chen, Chia-Ling
2017-10-01
The Motor Activity Log (MAL) and Lower-Functioning MAL (LF-MAL) are used to assess the amount of use of the more impaired arm and the quality of movement during activities in real-life situations for patients with stroke. This study used Rasch analysis to examine the psychometric properties of the MAL and LF-MAL in patients with stroke. This is a methodological study. The MAL and LF-MAL include 2 scales: the amount of use (AOU) and the quality of movement (QOM). Rasch analysis was used to examine the unidimensionality, item difficulty hierarchy, targeting, reliability, and differential item functioning (DIF) of the MAL and LF-MAL. A total of 403 patients with mild or moderate stroke completed the MAL, and 134 patients with moderate/severe stroke finished the LF-MAL. Evidence of disordered thresholds and poor model fit were found both in the MAL and LF-MAL. After the rating categories were collapsed and misfit items were deleted, all items of the revised MAL and LF-MAL exhibited ordering and constituted unidimensional constructs. The person-item map showed that these assessments were difficult for our participants. The person reliability coefficients of these assessments ranged from .79 to .87. No items in the revised MAL and LF-MAL exhibited bias related to patients' characteristics. One limitation is the recruited patients, who have relatively high-functioning ability in the LF-MAL. The revised MAL and LF-MAL are unidimensional scales and have good reliability. The categories function well, and responses to all items in these assessments are not biased by patients' characteristics. However, the revised MAL and LF-MAL both showed floor effect. Further study might add easy items for assessing the performance of activity in real-life situations for patients with stroke. © 2017 American Physical Therapy Association
[Modification and evaluation of assessment of medication literacy].
Zheng, Feng; Zhong, Zhuqing; Ding, Siqing; Luo, Aijing; Liu, Zina
2016-11-28
To translate and revise the Medication Literacy Assessment in English (MedLitRxSE-English) and evaluate its validity and reliability. Methods: We introduced MedLitRxSE-English from abroad. According to the principles of Brislin and culture adjustment, we revised it as a Chinese edition. Using random sampling method, from Oct, 2014 to Jan, 2015, 461 non-hospitalized patients from the outpatient departments of the top three hospitals in Changsha city were investigated. The reliability and validity of the scale was tested. Results: The test-retest reliability of the Chinese version for medication literacy scale was 0.885; the split reliability was 0.840; K-R was 0.820; the correlations between the assessment of medication literacy and the corresponding items were 0.427-0.587; the confirmatory factor analysis revealed overall good fit. Root mean square error of approximation (RMSEA), χ2/df, goodness of fit index (GFI) and comparative fit index (CFI) was 0.08, 3.06, 0.91 and 0.94, respectively. Conclusion: The Chinese version for the assessment of medication literacy is in good reliability and validity, and it can be used to evaluate the medication literacy in our country.
Measurement of sedentary behaviour in population health surveys: a review and recommendations
LeBlanc, Allana G.; Colley, Rachel C.; Saunders, Travis J.
2017-01-01
Background The purpose of this review was to determine the most valid and reliable questions for targeting key modes of sedentary behaviour (SB) in a broad range of national and international health surveillance surveys. This was done by reviewing the SB modules currently used in population health surveys, as well as examining SB questionnaires that have performed well in psychometric testing. Methods Health surveillance surveys were identified via scoping review and contact with experts in the field. Previous systematic reviews provided psychometric information on pediatric questionnaires. A comprehensive search of four bibliographic databases was used to identify studies reporting psychometric information for adult questionnaires. Only surveys/studies published/used in English or French were included. Results The review identified a total of 16 pediatric and 18 adult national/international surveys assessing SB, few of which have undergone psychometric testing. Fourteen pediatric and 35 adult questionnaires with psychometric information were included. While reliability was generally good to excellent for questions targeting key modes of SB, validity was poor to moderate, and reported much less frequently. The most valid and reliable questions targeting specific modes of SB were combined to create a single questionnaire targeting key modes of SB. Discussion Our results highlight the importance of including SB questions in survey modules that are adaptable, able to assess various modes of SB, and that exhibit adequate reliability and validity. Future research could investigate the psychometric properties of the module we have proposed in this paper, as well as other questionnaires currently used in national and international population health surveys. PMID:29250468
Measurement of sedentary behaviour in population health surveys: a review and recommendations.
Prince, Stephanie A; LeBlanc, Allana G; Colley, Rachel C; Saunders, Travis J
2017-01-01
The purpose of this review was to determine the most valid and reliable questions for targeting key modes of sedentary behaviour (SB) in a broad range of national and international health surveillance surveys. This was done by reviewing the SB modules currently used in population health surveys, as well as examining SB questionnaires that have performed well in psychometric testing. Health surveillance surveys were identified via scoping review and contact with experts in the field. Previous systematic reviews provided psychometric information on pediatric questionnaires. A comprehensive search of four bibliographic databases was used to identify studies reporting psychometric information for adult questionnaires. Only surveys/studies published/used in English or French were included. The review identified a total of 16 pediatric and 18 adult national/international surveys assessing SB, few of which have undergone psychometric testing. Fourteen pediatric and 35 adult questionnaires with psychometric information were included. While reliability was generally good to excellent for questions targeting key modes of SB, validity was poor to moderate, and reported much less frequently. The most valid and reliable questions targeting specific modes of SB were combined to create a single questionnaire targeting key modes of SB. Our results highlight the importance of including SB questions in survey modules that are adaptable, able to assess various modes of SB, and that exhibit adequate reliability and validity. Future research could investigate the psychometric properties of the module we have proposed in this paper, as well as other questionnaires currently used in national and international population health surveys.
Gómez-Ortiz, Olga; Romera, Eva M.; Ortega-Ruiz, Rosario; Cabello, Rosario; Fernández-Berrocal, Pablo
2016-01-01
Emotion regulation (ER) is a basic psychological process that has been broadly linked to psychosocial adjustment. Due to its relationship with psychosocial adjustment, a significant number of instruments have been developed to assess emotion regulation in a reliable and valid manner. Among these, the Emotion Regulation Questionnaire (ERQ; Gross and John, 2003) is one of the most widely used, having shown good psychometric properties with adult samples from different cultures. Studies of validation in children and adolescents are, however, scarce and have only been developed for the Australian and Portuguese populations. The aim of this study was to validate the Spanish version of the ERQ for use in adolescents and determine possible differences according to the gender and age of young people. The sample consisted of 2060 adolescents (52.1% boys). Exploratory and Confirmatory factor analysis (EFA and CFA), multi-group analysis and Two-way multivariate analysis of variance (MANOVA) were performed and the percentiles calculated. The results of the AFE and CFA corroborated the existence of two factors related to the emotion regulation strategies of cognitive reappraisal and expressive suppression, showing acceptable internal consistency and test-retest reliability. Both factors also showed good criterion validity with personality traits, self-esteem, and social anxiety. Differences in cognitive reappraisal were found with regard to age, with younger students exhibiting the greatest mastery of this strategy. Gender differences were observed regarding the expressive suppression strategy, with boys being more likely to use this strategy than girls. A gender-age interaction effect was also observed, revealing that the use of the expressive suppression strategy did not vary by age in girls, and was more widely used by boys aged 12–14 years than those aged 15–16 years. However, we found evidence of measurement invariance across sex and age groups. The results suggest that the ERQ is a valid and reliable instrument that can be used to evaluate emotion regulation strategies in adolescents. PMID:26779076
McVilly, K; Webber, L; Paris, M; Sharp, G
2013-08-01
Having an objective means of evaluating the quality of behaviour support plans (BSPs) could assist service providers and statutory authorities to monitor and improve the quality of support provided to people with intellectual disability (ID) who exhibit challenging behaviour. The Behaviour Support Plan Quality Evaluation Guide II (BSP-QEII) was developed to monitor and assess BSPs prepared by teachers to support children with disability in the school system. This study investigated the application of the BSP-QEII to the assessment of BSPs for adults with ID in community support services. The inter-rater reliability of the BSP-QEII was assessed. The utility of the BPS-QEII was then investigated with reference to a time series study of matched pairs of BSPs, developed for the same clients over a period of approximately 3 years. Differences in plan quality measured across a number of service and systemic variables were also investigated. The BSP-QEII was found to have good inter-rater reliability and good utility for audit purposes. It was able to discriminate changes in plan quality over time. Differences in plan quality were also evident across different service types, where specialist staff had or had not been involved, and in some instances where a statutory format for the plan had or had not been used. There were no differences between plans developed by government and community sector agencies, nor were there any regional differences across the jurisdiction. The BSP-QEII could usefully be adopted as an audit tool for measuring the quality of BSPs for adults with ID. In addition to being used for research and administrative auditing, the principles underpinning the BSP-QEII could also be useful to guide policy and educational activities for staff in community based services for adults with ID. © 2012 The Authors. Journal of Intellectual Disability Research © 2012 John Wiley & Sons Ltd, MENCAP & IASSID.
NASA Astrophysics Data System (ADS)
English, Kirk L.; Hackney, Kyle J.; De Witt, John K.; Ploutz-Snyder, Robert J.; Goetchius, Elizabeth L.; Ploutz-Snyder, Lori L.
2013-11-01
IntroductionInternational Space Station (ISS) crewmembers perform muscle strength and endurance testing pre- and postflight to assess the physiologic adaptations associated with long-duration exposure to microgravity. However, a reliable and standardized method to document strength changes in-flight has not been established. To address this issue, a proprietary dynamometer, the Muscle Atrophy Research and Exercise System (MARES) has been developed and flown aboard the ISS. The aims of this ground-based investigation were to: (1) evaluate the test-retest reliability of MARES and (2) determine its agreement with a commercially available isokinetic dynamometer previously used for pre- and postflight medical testing. MethodsSix males (179.5±4.7 cm; 82.0±8.7 kg; 31.3±4.0 yr) and four females (163.2±7.3 cm; 63.2±1.9 kg; 32.3±6.8 yr) completed two testing sessions on a HUMAC NORM isokinetic dynamometer (NORM) and two sessions on MARES using a randomized, counterbalanced, cross-over design. Peak torque values at 60° and 180° s-1 were calculated from five maximal repetitions of knee extension (KE) and knee flexion (KF) for each session. Total work at 180° s-1 was determined from the area under the torque versus displacement curve during 20 maximal repetitions of KE and KF. ResultsIntraclass correlation coefficients were relatively high for both devices (0.90-0.99). Only one dependent measure, KE peak torque at 60° s-1 exhibited good concordance between devices (ρ=0.92) and a small average difference (0.9±17.3 N m). ConclusionMARES demonstrated acceptable test-retest reliability and thus should serve as a good tool to monitor in-flight strength changes. However, due to poor agreement with NORM, it is not advisable to compare absolute values obtained on these devices.
Tsugawa, Yusuke; Ohbu, Sadayoshi; Cruess, Richard; Cruess, Sylvia; Okubo, Tomoya; Takahashi, Osamu; Tokuda, Yasuharu; Heist, Brian S; Bito, Seiji; Itoh, Toshiyuki; Aoki, Akiko; Chiba, Tsutomu; Fukui, Tsuguya
2011-08-01
Despite the growing importance of and interest in medical professionalism, there is no standardized tool for its measurement. The authors sought to verify the validity, reliability, and generalizability of the Professionalism Mini-Evaluation Exercise (P-MEX), a previously developed and tested tool, in the context of Japanese hospitals. A multicenter, cross-sectional evaluation study was performed to investigate the validity, reliability, and generalizability of the P-MEX in seven Japanese hospitals. In 2009-2010, 378 evaluators (attending physicians, nurses, peers, and junior residents) completed 360-degree assessments of 165 residents and fellows using the P-MEX. The content validity and criterion-related validity were examined, and the construct validity of the P-MEX was investigated by performing confirmatory factor analysis through a structural equation model. The reliability was tested using generalizability analysis. The contents of the P-MEX achieved good acceptance in a preliminary working group, and the poststudy survey revealed that 302 (79.9%) evaluators rated the P-MEX items as appropriate, indicating good content validity. The correlation coefficient between P-MEX scores and external criteria was 0.78 (P < .001), demonstrating good criterion-related validity. Confirmatory factor analysis verified high path coefficient (0.60-0.99) and adequate goodness of fit of the model. The generalizability analysis yielded a high dependability coefficient, suggesting good reliability, except when evaluators were peers or junior residents. Findings show evidence of adequate validity, reliability, and generalizability of the P-MEX in Japanese hospital settings. The P-MEX is the only evaluation tool for medical professionalism verified in both a Western and East Asian cultural context.
2013-01-01
Summary of background data Recent smartphones, such as the iPhone, are often equipped with an accelerometer and magnetometer, which, through software applications, can perform various inclinometric functions. Although these applications are intended for recreational use, they have the potential to measure and quantify range of motion. The purpose of this study was to estimate the intra and inter-rater reliability as well as the criterion validity of the clinometer and compass applications of the iPhone in the assessment cervical range of motion in healthy participants. Methods The sample consisted of 28 healthy participants. Two examiners measured cervical range of motion of each participant twice using the iPhone (for the estimation of intra and inter-reliability) and once with the CROM (for the estimation of criterion validity). Estimates of reliability and validity were then established using the intraclass correlation coefficient (ICC). Results We observed a moderate intra-rater reliability for each movement (ICC = 0.65-0.85) but a poor inter-rater reliability (ICC < 0.60). For the criterion validity, the ICCs are moderate (>0.50) to good (>0.65) for movements of flexion, extension, lateral flexions and right rotation, but poor (<0.50) for the movement left rotation. Conclusion We found good intra-rater reliability and lower inter-rater reliability. When compared to the gold standard, these applications showed moderate to good validity. However, before using the iPhone as an outcome measure in clinical settings, studies should be done on patients presenting with cervical problems. PMID:23829201
Charlton, Paula C; Mentiplay, Benjamin F; Pua, Yong-Hao; Clark, Ross A
2015-05-01
Traditional methods of assessing joint range of motion (ROM) involve specialized tools that may not be widely available to clinicians. This study assesses the reliability and validity of a custom Smartphone application for assessing hip joint range of motion. Intra-tester reliability with concurrent validity. Passive hip joint range of motion was recorded for seven different movements in 20 males on two separate occasions. Data from a Smartphone, bubble inclinometer and a three dimensional motion analysis (3DMA) system were collected simultaneously. Intraclass correlation coefficients (ICCs), coefficients of variation (CV) and standard error of measurement (SEM) were used to assess reliability. To assess validity of the Smartphone application and the bubble inclinometer against the three dimensional motion analysis system, intraclass correlation coefficients and fixed and proportional biases were used. The Smartphone demonstrated good to excellent reliability (ICCs>0.75) for four out of the seven movements, and moderate to good reliability for the remaining three movements (ICC=0.63-0.68). Additionally, the Smartphone application displayed comparable reliability to the bubble inclinometer. The Smartphone application displayed excellent validity when compared to the three dimensional motion analysis system for all movements (ICCs>0.88) except one, which displayed moderate to good validity (ICC=0.71). Smartphones are portable and widely available tools that are mostly reliable and valid for assessing passive hip range of motion, with potential for large-scale use when a bubble inclinometer is not available. However, caution must be taken in its implementation as some movement axes demonstrated only moderate reliability. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
DiCesare, Christopher A; Bates, Nathaniel A; Barber Foss, Kim D; Thomas, Staci M; Wordeman, Samuel C; Sugimoto, Dai; Roewer, Benjamin D; Medina McKeon, Jennifer M; Di Stasi, Stephanie; Noehren, Brian W; Ford, Kevin R; Kiefer, Adam W; Hewett, Timothy E; Myer, Gregory D
2015-12-01
Anterior cruciate ligament (ACL) injuries are physically and financially devastating but affect a relatively small percentage of the population. Prospective identification of risk factors for ACL injury necessitates a large sample size; therefore, study of this injury would benefit from a multicenter approach. To determine the reliability of kinematic and kinetic measures of a single-leg cross drop task across 3 institutions. Controlled laboratory study. Twenty-five female high school volleyball players participated in this study. Three-dimensional motion data of each participant performing the single-leg cross drop were collected at 3 institutions over a period of 4 weeks. Coefficients of multiple correlation were calculated to assess the reliability of kinematic and kinetic measures during the landing phase of the movement. Between-centers reliability for kinematic waveforms in the frontal and sagittal planes was good, but moderate in the transverse plane. Between-centers reliability for kinetic waveforms was good in the sagittal, frontal, and transverse planes. Based on these findings, the single-leg cross drop task has moderate to good reliability of kinematic and kinetic measures across institutions after implementation of a standardized testing protocol. Multicenter collaborations can increase study numbers and generalize results, which is beneficial for studies of relatively rare phenomena, such as ACL injury. An important step is to determine the reliability of risk assessments across institutions before a multicenter collaboration can be initiated.
DiCesare, Christopher A.; Bates, Nathaniel A.; Barber Foss, Kim D.; Thomas, Staci M.; Wordeman, Samuel C.; Sugimoto, Dai; Roewer, Benjamin D.; Medina McKeon, Jennifer M.; Di Stasi, Stephanie; Noehren, Brian W.; Ford, Kevin R.; Kiefer, Adam W.; Hewett, Timothy E.; Myer, Gregory D.
2015-01-01
Background: Anterior cruciate ligament (ACL) injuries are physically and financially devastating but affect a relatively small percentage of the population. Prospective identification of risk factors for ACL injury necessitates a large sample size; therefore, study of this injury would benefit from a multicenter approach. Purpose: To determine the reliability of kinematic and kinetic measures of a single-leg cross drop task across 3 institutions. Study Design: Controlled laboratory study. Methods: Twenty-five female high school volleyball players participated in this study. Three-dimensional motion data of each participant performing the single-leg cross drop were collected at 3 institutions over a period of 4 weeks. Coefficients of multiple correlation were calculated to assess the reliability of kinematic and kinetic measures during the landing phase of the movement. Results: Between-centers reliability for kinematic waveforms in the frontal and sagittal planes was good, but moderate in the transverse plane. Between-centers reliability for kinetic waveforms was good in the sagittal, frontal, and transverse planes. Conclusion: Based on these findings, the single-leg cross drop task has moderate to good reliability of kinematic and kinetic measures across institutions after implementation of a standardized testing protocol. Clinical Relevance: Multicenter collaborations can increase study numbers and generalize results, which is beneficial for studies of relatively rare phenomena, such as ACL injury. An important step is to determine the reliability of risk assessments across institutions before a multicenter collaboration can be initiated. PMID:26779550
Verheijde, Joseph L; White, Fred; Tompkins, James; Dahl, Peder; Hentz, Joseph G; Lebec, Michael T; Cornwall, Mark
2013-12-01
To investigate reliability, validity, and sensitivity to change of the Lower Extremity Functional Scale (LEFS) in individuals affected by stroke. The secondary objective was to test the validity and sensitivity of a single-item linear analog scale (LAS) of function. Prospective cohort reliability and validation study. A single rehabilitation department in an academic medical center. Forty-three individuals receiving neurorehabilitation for lower extremity dysfunction after stroke were studied. Their ages ranged from 32 to 95 years, with a mean of 70 years; 77% were men. Test-retest reliability was assessed by calculating the classical intraclass correlation coefficient, and the Bland-Altman limits of agreement. Validity was assessed by calculating the Pearson correlation coefficient between the instruments. Sensitivity to change was assessed by comparing baseline scores with end of treatment scores. Measurements were taken at baseline, after 1-3 days, and at 4 and 8 weeks. The LEFS, Short-Form-36 Physical Function Scale, Berg Balance Scale, Six-Minute Walk Test, Five-Meter Walk Test, Timed Up-and-Go test, and the LAS of function were used. The test-retest reliability of the LEFS was found to be excellent (ICC = 0.96). Correlated with the 6 other measures of function studied, the validity of the LEFS was found to be moderate to high (r = 0.40-0.71). Regarding the sensitivity to change, the mean LEFS scores from baseline to study end increased 1.2 SD and for LAS 1.1 SD. LEFS exhibits good reliability, validity, and sensitivity to change in patients with lower extremity impairments secondary to stroke. Therefore, the LEFS can be a clinically efficient outcome measure in the rehabilitation of patients with subacute stroke. The LAS is shown to be a time-saving and reasonable option to track changes in a patient's functional status. Copyright © 2013 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Vasconcelos-Raposo, José; Fernandes, Helder Miguel; Teixeira, Carla M
2013-01-01
The purpose of the present study was to assess the factor structure and reliability of the Depression, Anxiety and Stress Scales (DASS-21) in a large Portuguese community sample. Participants were 1020 adults (585 women and 435 men), with a mean age of 36.74 (SD = 11.90) years. All scales revealed good reliability, with Cronbach's alpha values between .80 (anxiety) and .84 (depression). The internal consistency of the total score was .92. Confirmatory factor analysis revealed that the best-fitting model (*CFI = .940, *RMSEA = .038) consisted of a latent component of general psychological distress (or negative affectivity) plus orthogonal depression, anxiety and stress factors. The Portuguese version of the DASS-21 showed good psychometric properties (factorial validity and reliability) and thus can be used as a reliable and valid instrument for measuring depression, anxiety and stress symptoms.
Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys
2010-01-01
Background Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Methods Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. Results The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Conclusions Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting. PMID:20958990
Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys.
van den Akker-Scheek, Inge; van Raay, Jos J A M; Reininga, Inge H F; Bulstra, Sjoerd K; Zijlstra, Wiebren; Stevens, Martin
2010-10-19
Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting.
System reliability and recovery.
DOT National Transportation Integrated Search
1971-06-01
The paper exhibits a variety of reliability techniques applicable to future ATC data processing systems. Presently envisioned schemes for error detection, error interrupt and error analysis are considered, along with methods of retry, reconfiguration...
Hua, Li; Wu, Yi-Ping; An, Bing; Lai, Xiao-Wei
2008-11-01
The harm of heavy metals contained in electronic and electrical equipment (EEE) on environment is of high concern by human. Aiming to handle the great challenge of RoHS compliance, the determinations of trace or ultratrace chromium (Cr), cadmium (Cd), mercury (Hg) and lead (Pb) by inductively coupled plasma optical emission spectrometry (ICP-OES) was performed in the present paper, wherein, microwave extraction technology was used to prepare the sample solutions. In addition, the precision, recovery, repeatability and interference issues of this method were also discussed. The results exhibited that using the microwave extraction system to prepare samples is more quick, lossless, contamination-free in comparison with the conventional extraction methods such as dry ashing, wet-oven extraction etc. By analyzing the recoveries of these four heavy metals over different working time and wavelengths, the good recovery range between 85% and 115% showed that there was only tiny loss or contamination during the process of microwave extraction, sample introduction and ICP detection. Repeatability experiments proved that ICP plasma had a good stability during the working time and the matrix effect was small. Interference was a problem troublesome for atomic absorption spectrometry (AAS), however, the techniques of standard additions or inter-element correction (IEC) method can effectively eliminated the interferences of Ni, As, Fe etc. with the Cd determination. By employing the multi-wavelengths and two correction point methods, the issues of background curve sloping shift and spectra overlap were successfully overcome. Besides, for the determinations of trace heavy metal elements, the relative standard deviation (RSD) was less than 3% and the detection limits were less than 1 microg x L(-10 (3sigma, n = 5) for samples, standard solutions, and standard additions, which proved that ICP-OES has a good precision and high reliability. This provided a reliable technique support for electronic and electrical (EE) industries to comply with RoHS directive.
The pathogen transmission avoidance theory of sexual selection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loehle, C.
1997-08-01
The current theory that sexual selection results from female preference for males with good genes suffers from several problems. An alternative explanation, the pathogen transmission avoidance hypothesis, argues that the primary function of showy traits is to provide a reliable signal of current disease status, so that sick individuals can be avoided during mating. This study shows that a significant risk of pathogen transmission occurs during mating and that showy traits are reliable indicators of current disease status. The origin of female choosiness is argued to lie in a general tendency to avoid sick individuals, even in the absence ofmore » showy traits, which originate as exaggerations of normal traits that are indicative of good health (bright feathers, vigorous movement, large size). Thus, in this new model the origins of both showy traits and female choosiness are not problematic and there is no threshold effect. This model predicts that when the possession of male showy traits does not help to reduce disease in the female, showy traits are unlikely to occur. This case corresponds to thorough exposure of every animal to all group pathogens, on average, in large groups. Such species are shown with a large data set on birds to be less likely to exhibit showy traits. The good-genes model does not make this prediction. The pathogen transmission avoidance model can also lead to the evolution of showy traits even when selection is not effective against a given pathogen (e.g., when there is no heritable variation for resistance), but can result in selection for resistance if such genes are present. Monogamy is argued to reduce selection pressures for showy traits; data show monogamous species to be both less parasitized and less showy. In the context of reduction of pathogen transmission rates in showy populations, selection pressure becomes inversely frequency-dependent, which makes showy traits likely to be self-limiting rather than runaway.« less
Stability of steady hand force production explored across spaces and methods of analysis.
de Freitas, Paulo B; Freitas, Sandra M S F; Lewis, Mechelle M; Huang, Xuemei; Latash, Mark L
2018-06-01
We used the framework of the uncontrolled manifold (UCM) hypothesis and explored the reliability of several outcome variables across different spaces of analysis during a very simple four-finger accurate force production task. Fourteen healthy, young adults performed the accurate force production task with each hand on 3 days. Small spatial finger perturbations were generated by the "inverse piano" device three times per trial (lifting the fingers 1 cm/0.5 s and lowering them). The data were analyzed using the following main methods: (1) computation of indices of the structure of inter-trial variance and motor equivalence in the space of finger forces and finger modes, and (2) analysis of referent coordinates and apparent stiffness values for the hand. Maximal voluntary force and the index of enslaving (unintentional finger force production) showed good to excellent reliability. Strong synergies stabilizing total force were reflected in both structure of variance and motor equivalence indices. Variance within the UCM and the index of motor equivalent motion dropped over the trial duration and showed good to excellent reliability. Variance orthogonal to the UCM and the index of non-motor equivalent motion dropped over the 3 days and showed poor to moderate reliability. Referent coordinate and apparent stiffness indices co-varied strongly and both showed good reliability. In contrast, the computed index of force stabilization showed poor reliability. The findings are interpreted within the scheme of neural control with referent coordinates involving the hierarchy of two basic commands, the r-command and c-command. The data suggest natural drifts in the finger force space, particularly within the UCM. We interpret these drifts as reflections of a trade-off between stability and optimization of action. The implications of these findings for the UCM framework and future clinical applications are explored in the discussion. Indices of the structure of variance and motor equivalence show good reliability and can be recommended for applied studies.
Reliability of Wearable Inertial Measurement Units to Measure Physical Activity in Team Handball.
Luteberget, Live S; Holme, Benjamin R; Spencer, Matt
2018-04-01
To assess the reliability and sensitivity of commercially available inertial measurement units to measure physical activity in team handball. Twenty-two handball players were instrumented with 2 inertial measurement units (OptimEye S5; Catapult Sports, Melbourne, Australia) taped together. They participated in either a laboratory assessment (n = 10) consisting of 7 team handball-specific tasks or field assessment (n = 12) conducted in 12 training sessions. Variables, including PlayerLoad™ and inertial movement analysis (IMA) magnitude and counts, were extracted from the manufacturers' software. IMA counts were divided into intensity bands of low (1.5-2.5 m·s -1 ), medium (2.5-3.5 m·s -1 ), high (>3.5 m·s -1 ), medium/high (>2.5 m·s -1 ), and total (>1.5 m·s -1 ). Reliability between devices and sensitivity was established using coefficient of variation (CV) and smallest worthwhile difference (SWD). Laboratory assessment: IMA magnitude showed a good reliability (CV = 3.1%) in well-controlled tasks. CV increased (4.4-6.7%) in more-complex tasks. Field assessment: Total IMA counts (CV = 1.8% and SWD = 2.5%), PlayerLoad (CV = 0.9% and SWD = 2.1%), and their associated variables (CV = 0.4-1.7%) showed a good reliability, well below the SWD. However, the CV of IMA increased when categorized into intensity bands (2.9-5.6%). The reliability of IMA counts was good when data were displayed as total, high, or medium/high counts. A good reliability for PlayerLoad and associated variables was evident. The CV of the previously mentioned variables was well below the SWD, suggesting that OptimEye's inertial measurement unit and its software are sensitive for use in team handball.
Powell, T; Brooker, D J; Papadopolous, A
1993-05-01
Relative and absolute test-retest reliability of the MEAMS was examined in 12 subjects with probable dementia and 12 matched controls. Relative reliability was good. Measures of absolute reliability showed scores changing by up to 3 points over an interval of a week. A version effect was found to be in evidence.
Effect of reflective p-type ohmic contact on thermal reliability of vertical InGaN/GaN LEDs
NASA Astrophysics Data System (ADS)
Son, Jun Ho; Song, Yang Hee; Kim, Buem Joon; Lee, Jong-Lam
2014-11-01
We report on the enhanced thermal reliability of vertical-LEDs (VLEDs) using novel reflective p-type ohmic contacts with good thermal stability. The reflective p-type ohmic contacts with Ni/Ag-Cu alloy multi-layer structure shows low contact resistivity, as low as 9.3 × 10-6 Ωcm2, and high reflectance of 86% after annealing at 450°C. The V-LEDs with Ni/Ag-Cu alloy multi-layer structure show good thermal reliability with stress time at 300°C in air ambient. The improved thermal stability of the reflective ohmic contacts to p-type GaN is believed to play a critical role in the thermal reliability of V-LEDs. [Figure not available: see fulltext.
Chang, Wen-Dien; Chang, Wan-Yi; Lee, Chia-Lun; Feng, Chi-Yen
2013-01-01
[Purpose] Balance is an integral part of human ability. The smart balance master system (SBM) is a balance test instrument with good reliability and validity, but it is expensive. Therefore, we modified a Wii Fit balance board, which is a convenient balance assessment tool, and analyzed its reliability and validity. [Subjects and Methods] We recruited 20 healthy young adults and 20 elderly people, and administered 3 balance tests. The correlation coefficient and intraclass correlation of both instruments were analyzed. [Results] There were no statistically significant differences in the 3 tests between the Wii Fit balance board and the SBM. The Wii Fit balance board had a good intraclass correlation (0.86–0.99) for the elderly people and positive correlations (r = 0.58–0.86) with the SBM. [Conclusions] The Wii Fit balance board is a balance assessment tool with good reliability and high validity for elderly people, and we recommend it as an alternative tool for assessing balance ability. PMID:24259769
Psychometrics of the MHSIP Adult Consumer Survey.
Jerrell, Jeanette M
2006-10-01
The reliability and validity of the Mental Health Statistics Improvement Program (MHSIP) Adult Consumer Survey were assessed in a statewide convenience sample of 459 persons with severe mental illness served through a public mental health system. Consistent with previous findings and the intent of its developers, three factors were identified that demonstrate good internal consistency, moderate test-retest reliability, and good convergent validity with consumer perceptions of other aspects of their care. The reliability and validity of the MHSIP Adult Consumer Survey documented in this study underscore its scientific and practical utility as an abbreviated tool for assessing access, quality and appropriateness, and outcome in mental health service systems.
Vespa, Anna; Giulietti, Maria Velia; Spatuzzi, Roberta; Fabbietti, Paolo; Meloni, Cristina; Gattafoni, Pisana; Ottaviani, Marica
2017-06-01
This study aimed at assessing the reliability and construct validity of Brief Multidimensional Measure of Religiousness/Spirituality (BMMRS) on Italian sample. 353 Italian participants: 58.9% affected by different diseases and 41.1% healthy subjects. The results of descriptive statistics of internal consistency reliabilities (Chronbach's coefficient) of the BMMRS revealed a remarkable consistency and reliability of different scales DSE, SpC, SC, CSC, VB, SPY-WELL and a good Inter-Class Correlations ≥70 maintaining a good stability of the measures over the time. BMMRS is a useful inventory for the evaluation of the principal spiritual dimensions.
Time-Dependent Behavior of Reinforced Polymer Concrete Columns under Eccentric Axial Loading
Berardi, Valentino Paolo; Mancusi, Geminiano
2012-01-01
Polymer concretes (PCs) represent a promising alternative to traditional cementitious materials in the field of new construction. In fact, PCs exhibit high compressive strength and ultimate compressive strain values, as well as good chemical resistance. Within the context of these benefits, this paper presents a study on the time-dependent behavior of polymer concrete columns reinforced with different bar types using a mechanical model recently developed by the authors. Balanced internal reinforcements are considered (i.e., two bars at both the top and bottom of the cross-section). The investigation highlights relevant stress and strain variations over time and, consequently, the emergence of a significant decrease in concrete’s stiffness and strength over time. Therefore, the results indicate that deferred effects due to viscous flow may significantly affect the reliability of reinforced polymer concrete elements over time.
Ab initio multireference study of the BN molecule
NASA Technical Reports Server (NTRS)
Martin, J. M. L.; Lee, Timothy J.; Scuseria, Gustavo E.; Taylor, Peter R.
1992-01-01
The lowest 1Sigma(+) and 3Pi states of the BN molecule are studied using multireference configuration interaction (MRCI) and averaged coupled-pair functional (ACPF) methods and large atomic natural orbital (ANO) basis sets, as well as several coupled cluster methods. Our calculations strongly support a 3Pi ground state, but the a1Sigma(+) state lies only 381 +/- 100/cm higher. The a1Sigma(+) state wave function exhibits strong multireference character and, consequently, the predictions of the perturbationally-based single-reference CCSD(T) coupled cluster method are not as reliable in this case as the multireference results. The theoretical predictions for the spectroscopic constants of BN are in good agreement with experiment for the Chi3Pi state, but strongly suggest a misassignment of the fundamental vibrational frequency for the a1Sigma(+) state.
Graphite nanocomposites sensor for multiplex detection of antioxidants in food.
Ng, Khan Loon; Tan, Guan Huat; Khor, Sook Mei
2017-12-15
Butylated hydroxyanisole (BHA), butylated hydroxytoluene (BHT), and tert-butylhydroquinone (TBHQ) are synthetic antioxidants used in the food industry. Herein, we describe the development of a novel graphite nanocomposite-based electrochemical sensor for the multiplex detection and measurement of BHA, BHT, and TBHQ levels in complex food samples using a linear sweep voltammetry technique. Moreover, our newly established analytical method exhibited good sensitivity, limit of detection, limit of quantitation, and selectivity. The accuracy and reliability of analytical results were challenged by method validation and comparison with the results of the liquid chromatography method, where a linear correlation of more than 0.99 was achieved. The addition of sodium dodecyl sulfate as supporting additive further enhanced the LSV response (anodic peak current, I pa ) of BHA and BHT by 2- and 20-times, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.
The Reliability, Impact, and Cost-Effectiveness of Value-Added Teacher Assessment Methods
ERIC Educational Resources Information Center
Yeh, Stuart S.
2012-01-01
This article reviews evidence regarding the intertemporal reliability of teacher rankings based on value-added methods. Value-added methods exhibit low reliability, yet are broadly supported by prominent educational researchers and are increasingly being used to evaluate and fire teachers. The article then presents a cost-effectiveness analysis…
Schneider, M M; Balke, M; Koenen, P; Fröhlich, M; Wafaisade, A; Bouillon, B; Banerjee, M
2016-07-01
The reliability of the Rockwood classification, the gold standard for acute acromioclavicular (AC) joint separations, has not yet been tested. The purpose of this study was to investigate the reliability of visual and measured AC joint lesion grades according to the Rockwood classification. Four investigators (two shoulder specialists and two second-year residents) examined radiographs (bilateral panoramic stress and axial views) in 58 patients and graded the injury according to the Rockwood classification using the following sequence: (1) visual classification of the AC joint lesion, (2) digital measurement of the coracoclavicular distance (CCD) and the horizontal dislocation (HD) with Osirix Dicom Viewer (Pixmeo, Switzerland), (3) classification of the AC joint lesion according to the measurements and (4) repetition of (1) and (2) after repeated anonymization by an independent physician. Visual and measured Rockwood grades as well as the CCD and HD of every patient were documented, and a CC index was calculated (CCD injured/CCD healthy). All records were then used to evaluate intra- and interobserver reliability. The disagreement between visual and measured diagnosis ranged from 6.9 to 27.6 %. Interobserver reliability for visual diagnosis was good (0.72-0.74) and excellent (0.85-0.93) for measured Rockwood grades. Intraobserver reliability was good to excellent (0.67-0.93) for visual diagnosis and excellent for measured diagnosis (0.90-0.97). The correlations between measurements of the axial view varied from 0.68 to 0.98 (good to excellent) for interobserver reliability and from 0.90 to 0.97 (excellent) for intraobserver reliability. Bilateral panoramic stress and axial radiographs are reliable examinations for grading AC joint injuries according to Rockwood's classification. Clinicians of all experience levels can precisely classify AC joint lesions according to the Rockwood classification. We recommend to grade acute ACG lesions by performing a digital measurement instead of a sole visual diagnosis because of the higher intra- and interobserver reliability. Case series, Level IV.
Geckili, Onur; Bilhan, Hakan; Cilingir, Altug; Bilmenoglu, Caglar; Ates, Gokcen; Urgun, Aliye Ceren; Bural, Canan
2014-12-01
A comparative ex vivo study was performed to determine electronic percussive test values (PTVs) measured by cabled and wireless electronic percussive testing (EPT) devices and to evaluate the intra- and interobserver reliability of the wireless EPT device. Forty implants were inserted into the vertebrae and forty into the pelvis of a steer, a safe distance apart. The implants were all 4.3 mm wide and 13 mm long, from the same manufacturer. PTV of each implant was measured by four different examiners, using both EPT devices, and compared. Additionally, the intra- and interobserver reliability of the wireless EPT device was evaluated. Statistically significant differences (P <0.05) were observed between PTVs made by the two EPT devices. PTVs measured by the wireless EPT device were significantly higher than the cabled EPT device (P <0.05), indicating lower implant stability. The intraobserver reliability of the wireless EPT device was evaluated as excellent for the measurements in type II bone and good-to-excellent in type IV bone; interobserver reliability was evaluated as fair-to-good in both bone types. The wireless EPT device gives PTVs higher than the cabled EPT device, indicating lower implant stability, and its inter- and intraobserver reliability is good and acceptable.
Yoshida, Masahito; Collin, Phillipe; Josseaume, Thierry; Lädermann, Alexandre; Goto, Hideyuki; Sugimoto, Katumasa; Otsuka, Takanobu
2018-01-01
Magnetic resonance (MR) imaging is common in structural and qualitative assessment of the rotator cuff post-operatively. Rotator cuff integrity has been thought to be associated with clinical outcome. The purpose of this study was to evaluate the inter-observer reliability of cuff integrity (Sugaya's classification) and assess the correlation between Sugaya's classification and the clinical outcome. It was hypothesized that Sugaya's classification would show good reliability and good correlation with the clinical outcome. Post-operative MR images were taken two years post-operatively, following arthroscopic rotator cuff repair. For assessment of inter-rater reliability, all radiographic evaluations for the supraspinatus muscle were done by two orthopaedic surgeons and one radiologist. Rotator cuff integrity was classified into five categories, according to Sugaya's classification. Fatty infiltration was graded into four categories, based on the Fuchs' classification grading system. Muscle hypotrophy was graded as four grades, according to the scale proposed by Warner. The clinical outcome was assessed according to the constant scoring system pre-operatively and 2 years post-operatively. Of the sixty-two consecutive patients with full-thickness rotator cuff tears, fifty-two patients were reviewed in this study. These subjects included twenty-three men and twenty-nine women, with an average age of fifty-seven years. In terms of the inter-rater reliability between orthopaedic surgeons, Sugaya's classification showed the highest agreement [ICC (2.1) = 0.82] for rotator cuff integrity. The grade of fatty infiltration and muscle atrophy demonstrated good agreement, respectively (0.722 and 0.758). With regard to the inter-rater reliability between orthopaedic surgeon and radiologist, Sugaya's classification showed good reliability [ICC (2.1) = 0.70]. On the other hand, fatty infiltration and muscle hypotrophy classifications demonstrated fair and moderate agreement [ICC (2.1) = 0.39 and 0.49]. Although no significant correlation was found between overall post-operative constant score and Sugaya's classification, Sugaya's classification indicated significant correlation with the muscle strength score. Sugaya's classification showed repeatability and good agreement between the orthopaedist and radiologist, who are involved in the patient care for the rotator cuff tear. Common classification of rotator cuff integrity with good reliability will give appropriate information for clinicians to improve the patient care of the rotator cuff tear. This classification also would be helpful to predict the strength of arm abduction in the scapular plane. IV.
An, Hyeong Su; Moon, Won-Jin; Ryu, Jae-Kyun; Park, Ju Yeon; Yun, Won Sung; Choi, Jin Woo; Jahng, Geon-Ho; Park, Jang-Yeon
2017-12-01
This prospective multi-center study aimed to evaluate the inter-vendor and test-retest reliabilities of resting-state functional magnetic resonance imaging (RS-fMRI) by assessing the temporal signal-to-noise ratio (tSNR) and functional connectivity. Study included 10 healthy subjects and each subject was scanned using three 3T MR scanners (GE Signa HDxt, Siemens Skyra, and Philips Achieva) in two sessions. The tSNR was calculated from the time course data. Inter-vendor and test-retest reliabilities were assessed with intra-class correlation coefficients (ICCs) derived from variant component analysis. Independent component analysis was performed to identify the connectivity of the default-mode network (DMN). In result, the tSNR for the DMN was not significantly different among the GE, Philips, and Siemens scanners (P=0.638). In terms of vendor differences, the inter-vendor reliability was good (ICC=0.774). Regarding the test-retest reliability, the GE scanner showed excellent correlation (ICC=0.961), while the Philips (ICC=0.671) and Siemens (ICC=0.726) scanners showed relatively good correlation. The DMN pattern of the subjects between the two sessions for each scanner and between three scanners showed the identical patterns of functional connectivity. The inter-vendor and test-retest reliabilities of RS-fMRI using different 3T MR scanners are good. Thus, we suggest that RS-fMRI could be used in multicenter imaging studies as a reliable imaging marker. Copyright © 2017 Elsevier Inc. All rights reserved.
Validity and Reliability of the Upper Extremity Work Demands Scale.
Jacobs, Nora W; Berduszek, Redmar J; Dijkstra, Pieter U; van der Sluis, Corry K
2017-12-01
Purpose To evaluate validity and reliability of the upper extremity work demands (UEWD) scale. Methods Participants from different levels of physical work demands, based on the Dictionary of Occupational Titles categories, were included. A historical database of 74 workers was added for factor analysis. Criterion validity was evaluated by comparing observed and self-reported UEWD scores. To assess structural validity, a factor analysis was executed. For reliability, the difference between two self-reported UEWD scores, the smallest detectable change (SDC), test-retest reliability and internal consistency were determined. Results Fifty-four participants were observed at work and 51 of them filled in the UEWD twice with a mean interval of 16.6 days (SD 3.3, range = 10-25 days). Criterion validity of the UEWD scale was moderate (r = .44, p = .001). Factor analysis revealed that 'force and posture' and 'repetition' subscales could be distinguished with Cronbach's alpha of .79 and .84, respectively. Reliability was good; there was no significant difference between repeated measurements. An SDC of 5.0 was found. Test-retest reliability was good (intraclass correlation coefficient for agreement = .84) and all item-total correlations were >.30. There were two pairs of highly related items. Conclusion Reliability of the UEWD scale was good, but criterion validity was moderate. Based on current results, a modified UEWD scale (2 items removed, 1 item reworded, divided into 2 subscales) was proposed. Since observation appeared to be an inappropriate gold standard, we advise to investigate other types of validity, such as construct validity, in further research.
Measuring eating disorder attitudes and behaviors: a reliability generalization study
2014-01-01
Background Although score reliability is a sample-dependent characteristic, researchers often only report reliability estimates from previous studies as justification for employing particular questionnaires in their research. The present study followed reliability generalization procedures to determine the mean score reliability of the Eating Disorder Inventory and its most commonly employed subscales (Drive for Thinness, Bulimia, and Body Dissatisfaction) and the Eating Attitudes Test as a way to better identify those characteristics that might impact score reliability. Methods Published studies that used these measures were coded based on their reporting of reliability information and additional study characteristics that might influence score reliability. Results Score reliability estimates were included in 26.15% of studies using the EDI and 36.28% of studies using the EAT. Mean Cronbach’s alphas for the EDI (total score = .91; subscales = .75 to .89), EAT-40 (total score = .81) and EAT-26 (total score = .86; subscales = .56 to .80) suggested variability in estimated internal consistency. Whereas some EDI subscales exhibited higher score reliability in clinical eating disorder samples than in nonclinical samples, other subscales did not exhibit these differences. Score reliability information for the EAT was primarily reported for nonclinical samples, making it difficult to characterize the effect of type of sample on these measures. However, there was a tendency for mean score reliability to be higher in the adult (vs. adolescent) samples and in female (vs. male) samples. Conclusions Overall, this study highlights the importance of assessing and reporting internal consistency during every test administration because reliability is affected by characteristics of the participants being examined. PMID:24764530
Perceptual and Acoustic Analyses of Good Voice Quality in Male Radio Performers.
Warhurst, Samantha; Madill, Catherine; McCabe, Patricia; Ternström, Sten; Yiu, Edwin; Heard, Robert
2017-03-01
Good voice quality is an asset to professional voice users, including radio performers. We examined whether (1) voices could be reliably categorized as good for the radio and (2) these categories could be predicted using acoustic measures. Male radio performers (n = 24) and age-matched male controls performed "The Rainbow Passage" as if presenting on the radio. Voice samples were rated using a three-stage paired-comparison paradigm by 51 naive listeners and perceptual categories were identified (Study 1), and then analyzed for fundamental frequency, long-term average spectrum, cepstral peak prominence, and pause or spoken-phrase duration (Study 2). Study 1: Good inter-judge reliability was found for perceptual judgments of the best 15 voices (good for radio category, 14/15 = radio performers), but agreement on the remaining 33 voices (unranked category) was poor. Study 2: Discriminant function analyses showed that the SD standard deviation of sounded portion duration, equivalent sound level, and smoothed cepstral peak prominence predicted membership of categories with moderate accuracy (R 2 = 0.328). Radio performers are heterogeneous for voice quality; good voice quality was judged reliably in only 14 out of 24 radio performers. Current acoustic analyses detected some of the relevant signal properties that were salient in these judgments. More refined perceptual analysis and the use of other perceptual methods might provide more information on the complex nature of judging good voices. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Hoenig, Helen M; Amis, Kristopher; Edmonds, Carol; Morgan, Michelle S; Landerman, Lawrence; Caves, Kevin
2017-01-01
Background There is limited research about the effects of video quality on the accuracy of assessments of physical function. Methods A repeated measures study design was used to assess reliability and validity of the finger-nose test (FNT) and the finger-tapping test (FTT) carried out with 50 veterans who had impairment in gross and/or fine motor coordination. Videos were scored by expert raters under eight differing conditions, including in-person, high definition video with slow motion review and standard speed videos with varying bit rates and frame rates. Results FTT inter-rater reliability was excellent with slow motion video (ICC 0.98-0.99) and good (ICC 0.59) under the normal speed conditions. Inter-rater reliability for FNT 'attempts' was excellent (ICC 0.97-0.99) for all viewing conditions; for FNT 'misses' it was good to excellent (ICC 0.89) with slow motion review but substantially worse (ICC 0.44) on the normal speed videos. FTT criterion validity (i.e. compared to slow motion review) was excellent (β = 0.94) for the in-person rater and good ( β = 0.77) on normal speed videos. Criterion validity for FNT 'attempts' was excellent under all conditions ( r ≥ 0.97) and for FNT 'misses' it was good to excellent under all conditions ( β = 0.61-0.81). Conclusions In general, the inter-rater reliability and validity of the FNT and FTT assessed via video technology is similar to standard clinical practices, but is enhanced with slow motion review and/or higher bit rate.
An Examination of the True Reliability of Lower Limb Stiffness Measures During Overground Hopping.
Diggin, David; Anderson, Ross; Harrison, Andrew J
2016-06-01
Evidence suggests reports describing the reliability of leg-spring (kleg) and joint stiffness (kjoint) measures are contaminated by artifacts originating from digital filtering procedures. In addition, the intraday reliability of kleg and kjoint requires investigation. This study examined the effects of experimental procedures on the inter- and intraday reliability of kleg and kjoint. Thirty-two participants completed 2 trials of single-legged hopping at 1.5, 2.2, and 3.0 Hz at the same time of day across 3 days. On the final test day a fourth experimental bout took place 6 hours before or after participants' typical testing time. Kinematic and kinetic data were collected throughout. Stiffness was calculated using models of kleg and kjoint. Classifications of measurement agreement were established using thresholds for absolute and relative reliability statistics. Results illustrated that kleg and kankle exhibited strong agreement. In contrast, kknee and khip demonstrated weak-to-moderate consistency. Results suggest limits in kjoint reliability persist despite employment of appropriate filtering procedures. Furthermore, diurnal fluctuations in lower-limb muscle-tendon stiffness exhibit little effect on intraday reliability. The present findings support the existence of kleg as an attractor state during hopping, achieved through fluctuations in kjoint variables. Limits to kjoint reliability appear to represent biological function rather than measurement artifact.
Semiconducting compounds and devices incorporating same
Marks, Tobin J; Facchetti, Antonio; Boudreault, Pierre-Luc; Miyauchi, Hiroyuki
2014-06-17
Disclosed are molecular and polymeric compounds having desirable properties as semiconducting materials. Such compounds can exhibit desirable electronic properties and possess processing advantages including solution-processability and/or good stability. Organic transistor and photovoltaic devices incorporating the present compounds as the active layer exhibit good device performance.
Semiconducting compounds and devices incorporating same
Marks, Tobin J.; Facchetti, Antonio; Boudreault, Pierre-Luc; Miyauchi, Hiroyuki
2016-01-19
Disclosed are molecular and polymeric compounds having desirable properties as semiconducting materials. Such compounds can exhibit desirable electronic properties and possess processing advantages including solution-processability and/or good stability. Organic transistor and photovoltaic devices incorporating the present compounds as the active layer exhibit good device performance.
A Novel Highly Sensitive NO2 Sensor Based on Perovskite Na0.5+xBi0.5TiO3-δ Electrolyte.
Xiao, Yihong; Zhang, Chufan; Zhang, Xu; Cai, Guohui; Zheng, Yong; Zheng, Ying; Zhong, Fulan; Jiang, Lilong
2017-07-10
NO x is one of dangerous air pollutants, and the demands for reliable sensors to detect NO x are extremely urgent recently. Conventional fluorite-phase YSZ used for NO x sensor requires higher operating temperature to obtain desirable oxygen ion conductivity. In this work, perovskite-phase Na 0.5 Bi 0.5 TiO 3 (NBT) oxygen conductor was chosen as the solid electrolyte to fabricate a novel highly sensitive NO 2 sensor with CuO as the sensing electrode and Pt as reference electrode. Na dopped Na 0.5 Bi 0.5 TiO 3 greatly improved the sensing performance of this sensor. The optimal sensor based on Na 0.51 Bi 0.50 TiO 3-δ exhibited good response-recovery characteristics to NO 2 and the response current values were almost linear to NO 2 concentrations in the range of 50-500 ppm at 400-600 °C. The response current value towards NO 2 reached maximum 11.23 μA at 575 °C and the value on NO 2 is much higher than other gases (CH 4 , C 2 H 4 , C 3 H 6 , C 3 H 8 , CO), indicating good selectivity for detecting NO 2 . The response signals of the sensor were slightly affected by coexistent O 2 varying from 2 to 21 vol% at 575 °C. The response current value decreased only 4.9% over 2 months, exhibiting the potential application in motor vehicles.
Psychometric evaluation of the Swedish version of Rosenberg's self-esteem scale.
Eklund, Mona; Bäckström, Martin; Hansson, Lars
2018-04-01
The widely used Rosenberg's self-esteem scale (RSES) has not been evaluated for psychometric properties in Sweden. This study aimed at analyzing its factor structure, internal consistency, criterion, convergent and discriminant validity, sensitivity to change, and whether a four-graded Likert-type response scale increased its reliability and validity compared to a yes/no response scale. People with mental illness participating in intervention studies to (1) promote everyday life balance (N = 223) or (2) remedy self-stigma (N = 103) were included. Both samples completed the RSES and questionnaires addressing quality of life and sociodemographic data. Sample 1 also completed instruments chosen to assess convergent and discriminant validity: self-mastery (convergent validity), level of functioning and occupational engagement (discriminant validity). Confirmatory factor analysis (CFA), structural equation modeling, and conventional inferential statistics were used. Based on both samples, the Swedish RSES formed one factor and exhibited high internal consistency (>0.90). The two response scales were equivalent. Criterion validity in relation to quality of life was demonstrated. RSES could distinguish between women and men (women scoring lower) and between diagnostic groups (people with depression scoring lower). Correlations >0.5 with variables chosen to reflect convergent validity and around 0.2 with variables used to address discriminant validity further highlighted the construct validity of RSES. The instrument also showed sensitivity to change. The Swedish RSES exhibited a one-component factor structure and showed good psychometric properties in terms of good internal consistency, criterion, convergent and discriminant validity, and sensitivity to change. The yes/no and the four-graded Likert-type response scales worked equivalently.
Comparison of simulation and experimental results for a model aqueous tert-butanol solution
NASA Astrophysics Data System (ADS)
Overduin, S. D.; Patey, G. N.
2017-07-01
Molecular dynamics simulations are used to investigate the behavior of aqueous tert-butanol (TBA) solutions for a range of temperatures, using the CHARMM generalized force field (CGenFF) to model TBA and the TIP4P/2005 or TIP4P-Ew water model. Simulation results for the density, isothermal compressibility, constant pressure heat capacity, and self-diffusion coefficients are in good accord with experimental measurements. Agreement with the experiment is particularly good at low TBA concentration, where experiments have revealed anomalies in a number of thermodynamic properties. Importantly, the CGenFF model does not exhibit liquid-liquid demixing at temperatures between 290 and 320 K (for systems of 32 000 molecules), in contrast with the situation for several other common TBA models [R. Gupta and G. N. Patey, J. Chem. Phys. 137, 034509 (2012)]. However, whereas real water and TBA are miscible at all temperatures where the liquid is stable, we observe some evidence of demixing at 340 K and above. To evaluate the structural properties at low concentrations, we compare with both neutron scattering and recent spectroscopic measurements. This reveals that while the CGenFF model is a definite improvement over other models that have been considered, the TBA molecules still exhibit a tendency to associate at low concentrations that is somewhat stronger than that indicated by experiments. Finally, we discuss the range and decay times of the long-range correlations, providing an indication of the system size and simulation times that are necessary in order to obtain reliable results for certain properties.
Intra- and Interobserver Reliability of Three Classification Systems for Hallux Rigidus.
Dillard, Sarita; Schilero, Christina; Chiang, Sharon; Pham, Peter
2018-04-18
There are over ten classification systems currently used in the staging of hallux rigidus. This results in confusion and inconsistency with radiographic interpretation and treatment. The reliability of hallux rigidus classification systems has not yet been tested. The purpose of this study was to evaluate intra- and interobserver reliability using three commonly used classifications for hallux rigidus. Twenty-one plain radiograph sets were presented to ten ACFAS board-certified foot and ankle surgeons. Each physician classified each radiograph based on clinical experience and knowledge according to the Regnauld, Roukis, and Hattrup and Johnson classification systems. The two-way mixed single-measure consistency intraclass correlation was used to calculate intra- and interrater reliability. The intrarater reliability of individual sets for the Roukis and Hattrup and Johnson classification systems was "fair to good" (Roukis, 0.62±0.19; Hattrup and Johnson, 0.62±0.28), whereas the intrarater reliability of individual sets for the Regnauld system bordered between "fair to good" and "poor" (0.43±0.24). The interrater reliability of the mean classification was "excellent" for all three classification systems. Conclusions Reliable and reproducible classification systems are essential for treatment and prognostic implications in hallux rigidus. In our study, Roukis classification system had the best intrarater reliability. Although there are various classification systems for hallux rigidus, our results indicate that all three of these classification systems show reliability and reproducibility.
Reliability Programs for Nonelectronic Designs. Volume 1
1983-04-01
to the system or component levels or to both and then Its degree of effectiveness. DOCUMENT ID TITLE/SUBJECT APPLICATION EFFECTIVENESS Sys ./Comp/Both...ID TITLE/SUBJECT APPLICATION EFFECTIVENESS ’ Sys ./Comp/Both Exc./Good/Poor MIL-STD-781B Reliability Tests Exponen- 1 1 1 1 Ii II tial Distribution MIL...DOCUMENT ID TITLE/SUBJECT APPLICATION EFFECTIVENESS Sys ./Comp/Both Exc./Good/Poor MIL-STD-1535A Supplier Quality Assurance I 1 I1 I 1 1 I Program
Modern psychometrics for assessing achievement goal orientation: a Rasch analysis.
Muis, Krista R; Winne, Philip H; Edwards, Ordene V
2009-09-01
A program of research is needed that assesses the psychometric properties of instruments designed to quantify students' achievement goal orientations to clarify inconsistencies across previous studies and to provide a stronger basis for future research. We conducted traditional psychometric and modern Rasch-model analyses of the Achievement Goals Questionnaire (AGQ, Elliot & McGregor, 2001) and the Patterns of Adaptive Learning Scale (PALS, Midgley et al., 2000) to provide an in-depth analysis of the two most popular instruments in educational psychology. For Study 1, 217 undergraduate students enrolled in educational psychology courses participated. Thirty-four were male and 181 were female (two did not respond). Participants completed the AGQ in the context of their educational psychology class. For Study 2, 126 undergraduate students enrolled in educational psychology courses participated. Thirty were male and 95 were female (one did not respond). Participants completed the PALS in the context of their educational psychology class. Traditional psychometric assessments of the AGQ and PALS replicated previous studies. For both, reliability estimates ranged from good to very good for raw subscale scores and fit for the models of goal orientations were good. Based on traditional psychometrics, the AGQ and PALS are valid and reliable indicators of achievement goals. Rasch analyses revealed that estimates of reliability for items were very good but respondent ability estimates varied from poor to good for both the AGQ and PALS. These findings indicate that items validly and reliably reflect a group's aggregate goal orientation, but using either instrument to characterize an individual's goal orientation is hazardous.
Wielenga, J M; De Vos, R; de Leeuw, R; De Haan, R J
2004-01-01
Assessment of clinimetric properties and diagnostic quality of a stress measurement scale (COMFORT scale). Sample of an open population. Neonatology department (Neonatal Intensive Care Unit), Academic Medical Centre/Emma Children's Hospital, Amsterdam, The Netherlands. One clinical expert and 9 observers observed ventilated premature born babies simultaneously. Criterion validity was assessed by correlating the COMFORT scale with the clinical judgment regarding the amount of stress. Interobserver reliability was assessed on the clinical judgment as well as on the COMFORT scale. Diagnostic qualities were evaluated with a ROC curve. On 19 ventilated prematurely born babies (mean gestational age 30 weeks, mean birth weight 1385 gm), one clinical expert and 9 observers made 30 paired observations. The criterion validity of the COMFORT scale was good (Pearson's r of 0.84). The interobserver reliability of the clinical judgment was very good (weighted Kappa 0.84). The interobserver reliability of each item varied from good to almost perfect (weighted Kappa of 0.64 for muscle tone to 1.00 on heart rate). The reliability of the total COMFORT scale score was satisfying (intra-class correlation coefficient of 0.94). The diagnostic quality of the COMFORT scale was excellent, at a cut-off point of 20 the sensitivity was 100 percent, the specificity was 77 percent, and the area under the curve (AUC) of 0.95. In this first evaluation, the COMFORT scale appears to be a valid and reliable measurement tool to assess the stress of ventilated prematurely born babies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chopade, Sujay A.; Anderson, Evan L.; Schmidt, Peter W.
Interfaces of ionic liquids and aqueous solutions exhibit stable electrical potentials over a wide range of aqueous electrolyte concentrations. This makes ionic liquids suitable as bridge materials that separate in electroanalytical measurements the reference electrode from samples with low and/or unknown ionic strengths. However, methods for the preparation of ionic liquid-based reference electrodes have not been explored widely. We have designed a convenient and reliable synthesis of ionic liquid-based reference electrodes by polymerization-induced microphase separation. This technique allows for a facile, single-pot synthesis of ready-to-use reference electrodes that incorporate ion conducting nanochannels filled with either 1-octyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide or 1-dodecyl-3-methylimidazolium bis(trifluoromethylmore » sulfonyl)imide as ionic liquid, supported by a mechanically robust cross-linked polystyrene phase. This synthesis procedure allows for the straightforward design of various reference electrode geometries. These reference electrodes exhibit a low resistance as well as good reference potential stability and reproducibility when immersed into aqueous solutions varying from deionized, purified water to 100 mM KCl, while requiring no correction for liquid junction potentials.« less
[Reliability and validity of Driving Anger Scale in professional drivers in China].
Li, Z; Yang, Y M; Zhang, C; Li, Y; Hu, J; Gao, L W; Zhou, Y X; Zhang, X J
2017-11-10
Objective: To assess the reliability and validity of the Chinese version of Driving Anger Scale (DAS) in professional drivers in China and provide a scientific basis for the application of the scale in drivers in China. Methods: Professional drivers, including taxi drivers, bus drivers, truck drivers and school bus drivers, were selected to complete the questionnaire. Cronbach's α and split-half reliability were calculated to evaluate the reliability of DAS, and content, contract, discriminant and convergent validity were performed to measure the validity of the scale. Results: The overall Cronbach's α of DAS was 0.934 and the split-half reliability was 0.874. The correlation coefficient of each subscale with the total scale was 0.639-0.922. The simplified version of DAS supported a presupposed six-factor structure, explaining 56.371% of the total variance revealed by exploratory factor analysis. The DAS had good convergent and discriminant validity, with the success rate of calibration experiment of 100%. Conclusion: DAS has a good reliability and validity in professional drivers in China, and the use of DAS is worth promoting in divers.
NASA Astrophysics Data System (ADS)
Pea, M.; Maiolo, L.; Giovine, E.; Rinaldi, A.; Araneo, R.; Notargiacomo, A.
2016-05-01
We report on the conductive-atomic force microscopy (C-AFM) study of metallic layers in order to find the most suitable configuration for electrical characterization of individual ZnO micro-pillars fabricated by focused ion beam (FIB). The electrical resistance between the probe tip and both as deposited and FIB processed metal layers (namely, Cr, Ti, Au and Al) has been investigated. Both chromium and titanium evidenced a non homogenous and non ohmic behaviour, non negligible scanning probe induced anodic oxidation associated to electrical measurements, and after FIB milling they exhibited significantly higher tip-sample resistance. Aluminium had generally a more apparent non conductive behaviour. Conversely, gold films showed very good tip-sample conduction properties being less sensitive to FIB processing than the other investigated metals. We found that a reliable C-AFM electrical characterization of ZnO microstructures obtained by FIB machining is feasible by using a combination of metal films as top contact layer. An Au/Ti bilayer on top of ZnO was capable to sustain the FIB fabrication process and to form a suitable ohmic contact to the semiconductor, allowing for reliable C-AFM measurement. To validate the consistency of this approach, we measured the resistance of ZnO micropillars finding a linear dependence on the pillar height, as expected for an ohmic conductor, and evaluated the resistivity of the material. This procedure has the potential to be downscaled to nanometer size structures by a proper choice of metal films type and thickness.
Muris, Peter; Ollendick, Thomas H; Roelofs, Jeffrey; Austin, Kristin
2014-12-01
The present study examined the psychometric properties of the Short Form of the Fear Survey Schedule for Children-Revised (FSSC-R-SF) in non-clinical and clinically referred children and adolescents from the Netherlands and the United States. Exploratory as well as confirmatory factor analyses of the FSSC-R-SF yielded support for the hypothesized five-factor structure representing fears in the domains of (1) failure and criticism, (2) the unknown, (3) animals, (4) danger and death, and (5) medical affairs. The FSSC-R-SF showed satisfactory reliability and was capable of assessing gender and age differences in youths' fears and fearfulness that have been documented in previous research. Further, the convergent validity of the scale was good as shown by substantial and meaningful correlations with the full-length FSSC-R and alternative childhood anxiety measures. Finally, support was found for the discriminant validity of the scale. That is, clinically referred children and adolescents exhibited higher scores on the FSSC-R-SF total scale and most subscales as compared to their non-clinical counterparts. Moreover, within the clinical sample, children and adolescents with a major anxiety disorder generally displayed higher FSSC-R-SF scores than youths without such a diagnosis. Altogether, these findings indicate that the FSSC-R-SF is a brief, reliable, and valid scale for assessing fear sensitivities in children and adolescents. Copyright © 2014 Elsevier Ltd. All rights reserved.
[Evaluation of Suicide Risk Levels in Hospitals: Validity and Reliability Tests].
Macagnino, Sandro; Steinert, Tilman; Uhlmann, Carmen
2018-05-01
Examination of in-hospital suicide risk levels concerning their validity and their reliability. The internal suicide risk levels were evaluated in a cross sectional study of in 163 inpatients. A reliability check was performed via determining interrater-reliability of senior physician, therapist and the responsible nurse. Within the scope of the validity check, we conducted analyses of criterion validity and construct validity. For the total sample an "acceptable" to "good" interrater-reliability (Kendalls W = .77) of suicide risk levels were obtained. Schizophrenic disorders showed the lowest values, for personality disorders we found the highest level of interrater-reliability. When examining the criterion validity, Item-9 of the BDI-II is substantial correlated to our suicide risk levels (ρ m = .54, p < .01). Within the scope of construct validity check, affective disorders showed the highest correlation (ρ = .77), compatible also with "convergent validity". They differed with schizophrenic disorders which showed the least concordance (ρ = .43). In-hospital suicide risk levels may represent an important contribution to the assessment of suicidal behavior of inpatients experiencing psychiatric treatment due to their overall good validity and reliability. © Georg Thieme Verlag KG Stuttgart · New York.
Peker, Kadriye; Köse, Taha Emre; Güray, Beliz; Uysal, Ömer; Erdem, Tamer Lütfi
2017-04-01
To culturally adapt the Turkish version of Rapid Estimate of Adult Literacy in Dentistry (TREALD-30) for Turkish-speaking adult dental patients and to evaluate its psychometric properties. After translation and cross-cultural adaptation, TREALD-30 was tested in a sample of 127 adult patients who attended a dental school clinic in Istanbul. Data were collected through clinical examinations and self-completed questionnaires, including TREALD-30, the Oral Health Impact Profile (OHIP), the Rapid Estimate of Adult Literacy in Medicine (REALM), two health literacy screening questions, and socio-behavioral characteristics. Psychometric properties were examined using Classical Test Theory (CTT) and Rasch analysis. Internal consistency (Cronbach's Alpha = 0.91) and test-retest reliability (Intraclass correlation coefficient = 0.99) were satisfactory for TREALD-30. It exhibited good convergent and predictive validity. Monthly family income, years of education, dental flossing, health literacy, and health literacy skills were found as stronger predictors of patients'oral health literacy (OHL). Confirmatory factor analysis (CFA) confirmed a two-factor model. The Rasch model explained 37.9% of the total variance in this dataset. In addition, TREALD-30 had eleven misfitting items, which indicated evidence of multidimensionality. The reliability indeces provided in Rasch analysis (person separation reliability = 0.91 and expected-a-posteriori/plausible reliability = 0.94) indicated that TREALD-30 had acceptable reliability. TREALD-30 showed satisfactory psychometric properties. It may be used to identify patients with low OHL. Socio-demographic factors, oral health behaviors and health literacy skills should be taken into account when planning future studies to assess the OHL in both clinical and community settings.
The medial tibial stress syndrome score: a new patient-reported outcome measure.
Winters, Marinus; Moen, Maarten H; Zimmermann, Wessel O; Lindeboom, Robert; Weir, Adam; Backx, Frank Jg; Bakker, Eric Wp
2016-10-01
At present, there is no validated patient-reported outcome measure (PROM) for patients with medial tibial stress syndrome (MTSS). Our aim was to select and validate previously generated items and create a valid, reliable and responsive PROM for patients with MTSS: the MTSS score. A prospective cohort study was performed in multiple sports medicine, physiotherapy and military facilities in the Netherlands. Participants with MTSS filled out the previously generated items for the MTSS score on 3 occasions. From previously generated items, we selected the best items. We assessed the MTSS score for its validity, reliability and responsiveness. The MTSS score was filled out by 133 participants with MTSS. Factor analysis showed the MTSS score to exhibit a single-factor structure with acceptable internal consistency (α=0.58) and good test-retest reliability (intraclass correlation coefficient=0.81). The MTSS score ranges from 0 to 10 points. The smallest detectable change in our sample was 0.69 at the group level and 4.80 at the individual level. Construct validity analysis showed significant moderate-to-large correlations (r=0.34-0.52, p<0.01). Responsiveness of the MTSS score was confirmed by a significant relation with the global perceived effect scale (β=-0.288, R(2)=0.21, p<0.001). The MTSS score is a valid, reliable and responsive PROM to measure the severity of MTSS. It is designed to evaluate treatment outcomes in clinical studies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Song, Rhayun; Oh, Hyunkyoung; Ahn, Sukhee; Moorhead, Sue
2018-02-01
The purpose of this study was to validate the Cardiac Health Behavior Scale for Korean adults (CHB-K) to determine its validity and reliability. Cardiovascular diseases (CVDs) are one of the most important chronic diseases due to their high prevalence and mortality rates. Patients with cardiovascular risks or diseases need to perform appropriate cardiac health behaviors that help to prevent the progression of the disease and improve their health status. This secondary analysis obtained data from two clinical trials of cardiac rehabilitation. Data from 298 patients with cardiovascular risks or diseases were analyzed for validation. Data analyses included correlation coefficients, t-tests, and exploratory and confirmatory factor analyses using SPSS (version WIN 22.0) and AMOS (version 20.0). The Self-Efficacy Scale was used to assess convergent validity, while reliability was assessed using Cronbach's alpha coefficients. Five main factors were verified: health responsibility, physical activity, diet habit (eating habit and food choice), stress management, and smoking cessation. A set of 21 items from the 25-item scale was verified after performing item analysis, factor analyses, and critical evaluation of the statistical results. The 21-item CHB-K (CHB-K21) exhibited acceptable validity, and the model of the CHB-K21 provided a good fit to the data. Most of the factors were found to be moderately correlated with SES scores (r=0.45-0.52, p<0.001). The CHB-K21 also demonstrated acceptable reliability (Cronbach's alpha=0.83). The CHB-K21 demonstrates strong validity and reliability. It can be used to assess cardiac health behaviors in Korean adults with cardiovascular risks or diseases. Copyright © 2017 Elsevier Inc. All rights reserved.
Validation of the Korean Version of the Scales for Outcomes in Parkinson's Disease-Sleep
2017-01-01
Background Sleep problems commonly occur in patients with Parkinson's disease (PD), and are associated with a lower quality of life. The aim of the current study was to translate the English version of the Scales for Outcomes in Parkinson's Disease-Sleep (SCOPA-S) into the Korean version of SCOPA-S (K-SCOPA-S), and to evaluate its reliability and validity for use by Korean-speaking patients with PD. Methods In total, 136 patients with PD from 27 movement disorder centres of university-affiliated hospitals in Korea were enrolled in this study. They were assessed using SCOPA, Hoehn and Yahr Scale (HYS), Unified Parkinson's Disease Rating Scale (UPDRS), Parkinson's Disease Sleep Scale 2nd version (PDSS-2), Non-motor Symptoms Scale (NMSS), Montgomery Asberg Depression Scale (MADS), 39-item Parkinson's Disease Questionnaire (PDQ39), Neurogenic Orthostatic Hypotension Questionnaire (NOHQ), and Rapid Eye Movement Sleep Behaviour Disorder Questionnaire (RBDQ). The test-retest reliability was assessed over a time interval of 10–14 days. Results The internal consistency (Cronbach's α-coefficients) of K-SCOPA-S was 0.88 for nighttime sleep (NS) and 0.75 for daytime sleepiness (DS). Test-retest reliability was 0.88 and 0.85 for the NS and DS, respectively. There was a moderate correlation between the NS sub-score and PDSS-2 total score. The NS and DS sub-scores of K-SCOPA-S were correlated with motor scale such as HYS, and non-motor scales such as UPDRS I, UPDRS II, MADS, NMSS, PDQ39, and NOHQ while the DS sub-score was with RBDQ. Conclusion The K-SCOPA-S exhibited good reliability and validity for the assessment of sleep problems in the Korean patients with PD. PMID:29215823
Validation of the Korean Version of the Scales for Outcomes in Parkinson's Disease-Sleep.
Sung, Young Hee; Kim, Hee Jin; Koh, Seong Beom; Kim, Joong Seok; Kim, Sang Jin; Cheon, Sang Myung; Cho, Jin Whan; Kim, Yoon Joong; Ma, Hyeo Il; Park, Mee Young; Baik, Jong Sam; Lee, Phil Hyu; Chung, Sun Ju; Kim, Jong Min; Song, In Uk; Kim, Han Joon; Kim, Ji Young; Kwon, Do Young; Lee, Jae Hyeok; Lee, Jee Young; Kim, Ji Seon; Yun, Ji Young; Hong, Jin Yong; Kim, Mi Jung; Youn, Jinyoung; Kim, Ji Sun; Oh, Eung Seok; Yang, Hui Jun; Yoon, Won Tae; You, Sooyeoun; Kwon, Kyum Yil; Park, Hyung Eun; Lee, Su Yun; Kim, Younsoo; Kim, Hee Tae; Ahn, Tae Beom
2018-01-08
Sleep problems commonly occur in patients with Parkinson's disease (PD), and are associated with a lower quality of life. The aim of the current study was to translate the English version of the Scales for Outcomes in Parkinson's Disease-Sleep (SCOPA-S) into the Korean version of SCOPA-S (K-SCOPA-S), and to evaluate its reliability and validity for use by Korean-speaking patients with PD. In total, 136 patients with PD from 27 movement disorder centres of university-affiliated hospitals in Korea were enrolled in this study. They were assessed using SCOPA, Hoehn and Yahr Scale (HYS), Unified Parkinson's Disease Rating Scale (UPDRS), Parkinson's Disease Sleep Scale 2nd version (PDSS-2), Non-motor Symptoms Scale (NMSS), Montgomery Asberg Depression Scale (MADS), 39-item Parkinson's Disease Questionnaire (PDQ39), Neurogenic Orthostatic Hypotension Questionnaire (NOHQ), and Rapid Eye Movement Sleep Behaviour Disorder Questionnaire (RBDQ). The test-retest reliability was assessed over a time interval of 10-14 days. The internal consistency (Cronbach's α-coefficients) of K-SCOPA-S was 0.88 for nighttime sleep (NS) and 0.75 for daytime sleepiness (DS). Test-retest reliability was 0.88 and 0.85 for the NS and DS, respectively. There was a moderate correlation between the NS sub-score and PDSS-2 total score. The NS and DS sub-scores of K-SCOPA-S were correlated with motor scale such as HYS, and non-motor scales such as UPDRS I, UPDRS II, MADS, NMSS, PDQ39, and NOHQ while the DS sub-score was with RBDQ. The K-SCOPA-S exhibited good reliability and validity for the assessment of sleep problems in the Korean patients with PD. © 2018 The Korean Academy of Medical Sciences.
NASA Astrophysics Data System (ADS)
Wang, Na; Zhang, Wei-bing; Tang, Bi-yu; Gao, Hai-Tao; He, En-jie; Wang, Lei
2018-07-01
The crystal structure, elastic and magnetic properties of important ternary Mg-based alloys NdMgT4 (T = Co, Ni, Cu) have been studied using reliable ab initio calculations. Both cohesive energy and charge density difference suggest that three alloys have good structural stability with the order: NdMgCo4 > NdMgNi4 > NdMgCu4. It shows that NdMgCo4 alloy has magnetic moments with the Co atoms being the main contribution, which is also in agreement with the calculated electronic structures. We find that NdMgT4 (T = Co, Ni, Cu) alloys are all ductile materials with bulk-to-shear modulus (B/G) values higher than 1.75. The trends of calculated values for the shear moduli Cs and C44 are consistent with that of shear modulus G and young's modulus E, proving that NdMgT4 (T = Co, Ni, Cu) alloys exhibit good plasticity with the trend: NdMgNi4 > NdMgCu4 > NdMgCo4. These calculated results give the basis guidance for the design of rare earth-magnesium-transition metal (R-Mg-T) alloys with improved mechanical properties.
Reliability and Validity of Prototype Diagnosis for Adolescent Psychopathology.
Haggerty, Greg; Zodan, Jennifer; Mehra, Ashwin; Zubair, Ayyan; Ghosh, Krishnendu; Siefert, Caleb J; Sinclair, Samuel J; DeFife, Jared
2016-04-01
The current study investigated the interrater reliability and validity of prototype ratings of 5 common adolescent psychiatric disorders: attention-deficit/hyperactivity disorder, conduct disorder, major depressive disorder, generalized anxiety disorder, and posttraumatic stress disorder. One hundred fifty-seven adolescent inpatient participants consented to participate in this study. We compared ratings from 2 inpatient clinicians, blinded to each other's ratings and patient measures, after their separate initial diagnostic interview to assess interrater reliability. Prototype ratings completed by clinicians after their initial diagnostic interview with adolescent inpatients and outpatients were compared with patient-reported behavior problems and parents' report of their child's behavioral problems. Prototype ratings demonstrated good interrater reliability. Clinicians' prototype ratings showed predicted relationships with patient-reported behavior problems and parent-reported behavior problems. Prototype matching seems to be a possible alternative for psychiatric diagnosis. Prototype ratings showed good interrater reliability based on clinicians unique experiences with the patient (as opposed to video-/audio-recorded material) with no training.
Krishnaprasad, Krupa; Andrews, Jane M; Lawrance, Ian C; Florin, Timothy; Gearry, Richard B; Leong, Rupert W L; Mahy, Gillian; Bampton, Peter; Prosser, Ruth; Leach, Peta; Chitti, Laurie; Cock, Charles; Grafton, Rachel; Croft, Anthony R; Cooke, Sharon; Doecke, James D; Radford-Smith, Graham L
2012-04-01
Crohn's disease (CD) exhibits significant clinical heterogeneity. Classification systems attempt to describe this; however, their utility and reliability depends on inter-observer agreement (IOA). We therefore sought to evaluate IOA using the Montreal Classification (MC). De-identified clinical records of 35 CD patients from 6 Australian IBD centres were presented to 13 expert practitioners from 8 Australia and New Zealand Inflammatory Bowel Disease Consortium (ANZIBDC) centres. Practitioners classified the cases using MC and forwarded data for central blinded analysis. IOA on smoking and medications was also tested. Kappa statistics, with pre-specified outcomes of κ>0.8 excellent; 0.61-0.8 good; 0.41-0.6 moderate and ≤0.4 poor, were used. 97% of study cases had colonoscopy reports, however, only 31% had undergone a complete set of diagnostic investigations (colonoscopy, histology, SB imaging). At diagnosis, IOA was excellent for age, κ=0.84; good for disease location, κ=0.73; only moderate for upper GI disease (κ=0.57) and disease behaviour, κ=0.54; and good for the presence of perianal disease, κ=0.6. At last follow-up, IOA was good for location, κ=0.68; only moderate for upper GI disease (κ=0.43) and disease behaviour, κ=0.46; but excellent for the presence/absence of perianal disease, κ=0.88. IOA for immunosuppressant use ever and presence of stricture were both good (κ=0.79 and 0.64 respectively). IOA using MC is generally good; however some areas are less consistent than others. Omissions and inaccuracies reduce the value of clinical data when comparing cohorts across different centres, and may impair the ability to translate genetic discoveries into clinical practice. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.
Savage, Jason W; Moore, Timothy A; Arnold, Paul M; Thakur, Nikhil; Hsu, Wellington K; Patel, Alpesh A; McCarthy, Kathryn; Schroeder, Gregory D; Vaccaro, Alexander R; Dimar, John R; Anderson, Paul A
2015-09-15
The thoracolumbar injury classification system (TLICS) was evaluated in 20 consecutive pediatric spine trauma cases. The purpose of this study was to determine the reliability and validity of the TLICS in pediatric spine trauma. The TLICS was developed to improve the categorization and management of thoracolumbar trauma. TLICS has been shown to have good reliability and validity in the adult population. The clinical and radiographical findings of 20 pediatric thoracolumbar fractures were prospectively presented to 20 surgeons with disparate levels of training and experience with spinal trauma. These injuries were consecutively scored using the TLICS. Cohen unweighted κ coefficients and Spearman rank order correlation values were calculated for the key parameters (injury morphology, status of posterior ligamentous complex, neurological status, TLICS total score, and proposed management) to assess the inter-rater reliabilities. Five surgeons scored the same cases 3 months later to assess the intra-rater reliability. The actual management of each case was then compared with the treatment recommended by the TLICS algorithm to assess validity. The inter-rater κ statistics of all subgroups (injury morphology, status of the posterior ligamentous complex, neurological status, TLICS total score, and proposed treatment) were within the range of moderate to substantial reproducibility (0.524-0.958). All subgroups had excellent intra-rater reliability (0.748-1.000). The various indices for validity were calculated (80.3% correct, 0.836 sensitivity, 0.785 specificity, 0.676 positive predictive value, 0.899 negative predictive value). Overall, TLICS demonstrated good validity. The TLICS has good reliability and validity when used in the pediatric population. The inter-rater reliability of predicting management and indices for validity are lower than those in adults with thoracolumbar fractures, which is likely due to differences in the way children are treated for certain types of injuries. TLICS can be used to reliably categorize thoracolumbar injuries in the pediatric population; however, modifications may be needed to better guide treatment in this specific patient population. 4.
Hu, Zhi-Jun; He, Jian; Zhao, Feng-Dong; Fang, Xiang-Qian; Zhou, Li-Na; Fan, Shun-Wu
2011-06-01
A reliability study was conducted. To estimate the intra- and intermeasurement errors in the measurements of functional cross-sectional area (FCSA), density, and T2 signal intensity of paraspinal muscles using computed tomography (CT) scan and magnetic resonance imaging (MRI). CT scan and MRI had been used widely to measure the cross-sectional area and degeneration of the back muscles in spine and muscle research. But there is still no systemic study to analyze the reliability of these measurements. This study measured the FCSA and fatty infiltration (density on CT scan and T2 signal intensity on MRI) of the paraspinal muscles at L3-L4, L4-L5, and L5-S1 in 29 patients with chronic low back pain. Two experienced musculoskeletal radiologists and one superior spine surgeon traced the region of interest twice within 3 weeks for measurement of the intra- and interobserver reliability. The intraclass correlation coefficients (ICCs) of the intra-reliability ranged from fair to excellent for FCSA, and good to excellent for fatty infiltration. The ICCs of the inter-reliability ranged from fair to excellent for FCSA, and good to excellent for fatty infiltration. There were no significant differences between CT scan and MRI in reliability results, except in the relative standard error of fatty infiltration measurement. The ICCs of the FCSA measurement between CT scan and MRI ranged from poor to good. The reliabilities of the CT scan and MRI for measuring the FCSA and fatty infiltration of the atrophied lumbar paraspinal muscles were acceptable. It was reliable for using uniform one image method for a single paraspinal muscle evaluation study. And the authors preferred to advise the MRI other than CT scan for paraspinal muscles measurements of FCSA and fatty infiltration.
Lunden, Jason B; Muffenbier, Mike; Giveans, M Russell; Cieminski, Cort J
2010-09-01
Clinical measurement, reliability. To compare intrarater and interrater reliability of shoulder internal rotation (IR) passive range of motion measurements utilizing a standard supine position and a sidelying position. Glenohumeral IR range of motion deficits are often noted in patients with shoulder pathology. Excellent intrarater reliability has been found when measuring this motion. However, interrater reliability has been reported as poor to fair. Some clinicians currently use a sidelying position for IR stretching with patients who have shoulder pathology. However, no objective data exist for IR passive range of motion measured in this sidelying position, either in terms of reliability or normative values. Seventy subjects (mean age, 36.8 years), with (n = 19) and without (n = 51) shoulder pathology, were included in this study. Shoulder IR passive range of motion of the dominant shoulder or involved shoulder was measured by 2 investigators in 2 positions: (1) a standard supine position, with the shoulder at 90 degrees of abduction, and (2) in sidelying on the tested side, with the shoulder flexed to 90 degrees . Intrarater reliability for supine measurements was good to excellent (ICC3,1 = 0.70-0.93) and for sidelying measurements was excellent (ICC3,1 = 0.94-0.98). Interrater reliability was fair to good for the supine measurement (ICC2,2 = 0.74-0.81) and good to excellent for the sidelying measurement (ICC2,2 = 0.88-0.96). The mean (range) value of the dominant shoulder sidelying IR passive range of motion was 40 degrees (11 degrees to 69 degrees ) for healthy subjects and 25 degrees (-16 degrees to 49 degrees) for subjects with shoulder pathology. For subjects with shoulder pathology, measurements of shoulder IR made in the sidelying position had superior intrarater and interrater reliability compared to those in the standard supine position.
Perraton, Luke G.; Bower, Kelly J.; Adair, Brooke; Pua, Yong-Hao; Williams, Gavin P.; McGaw, Rebekah
2015-01-01
Introduction Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power. Methods 30 healthy young adults (age: 23±5yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change. Results Comparison of RFD methods revealed that a peak 200ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ≥ 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ≥ 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31–0.79). Conclusions Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability and validity of these variables in clinical populations. PMID:26509265
The use of the isometric squat as a measure of strength and explosiveness.
Bazyler, Caleb D; Beckham, George K; Sato, Kimitake
2015-05-01
The isometric squat has been used to detect changes in kinetic variables as a result of training; however, controversy exists in its application to dynamic multijoint tasks. Thus, the purpose of this study was to further examine the relationship between isometric squat kinetic variables and isoinertial strength measures. Subjects (17 men, 1-repetition maximum [1RM]: 148.2 ± 23.4 kg) performed squats 2 d · wk(-1) for 12 weeks and were tested on 1RM squat, 1RM partial squat, and isometric squat at 90° and 120° of knee flexion. Test-retest reliability was very good for all isometric measures (intraclass correlation coefficients > 0.90); however, rate of force development 250 milliseconds at 90° and 120° seemed to have a higher systematic error (relative technical error of measurement = 8.12%, 9.44%). Pearson product-moment correlations indicated strong relationships between isometric peak force at 90° (IPF 90°) and 1RM squat (r = 0.86), and IPF 120° and 1RM partial squat (r = 0.79). Impulse 250 milliseconds (IMP) at 90° and 120° exhibited moderate to strong correlations with 1RM squat (r = 0.70, 0.58) and partial squat (r = 0.73, 0.62), respectively. Rate of force development at 90° and 120° exhibited weak to moderate correlations with 1RM squat (r = 0.55, 0.43) and partial squat (r = 0.32, 0.42), respectively. These findings demonstrate a degree of joint angle specificity to dynamic tasks for rapid and peak isometric force production. In conclusion, an isometric squat performed at 90° and 120° is a reliable testing measure that can provide a strong indication of changes in strength and explosiveness during training.
A new real-time visual assessment method for faulty movement patterns during a jump-landing task.
Rabin, Alon; Levi, Ran; Abramowitz, Shai; Kozol, Zvi
2016-07-01
Determine the interrater reliability of a new real-time assessment of faulty movement patterns during a jump-landing task. Interrater reliability study. Human movement laboratory. 50 healthy females. Assessment included 6 items which were evaluated from a front and a side view. Two Physical Therapy students used a 9-point scale (0-8) to independently rate the quality of movement as good (0-2), moderate (3-5), or poor (6-8). Interrater reliability was expressed by percent agreement and weighted kappa. One examiner rated the quality of movement of 6 subjects as good, 34 subjects as moderate, and 10 subjects as poor. The second examiner rated the quality of movement of 12 subjects as good, 23 subjects as moderate, and 15 subjects as poor. Percent agreement and weighted kappa (95% confidence interval) were 78% and 0.68 (0.51, 0.85), respectively. A new real-time assessment of faulty movement patterns during jump-landing demonstrated adequate interrater reliability. Further study is warranted to validate this method against a motion analysis system, as well as to establish its predictive validity for injury. Copyright © 2015 Elsevier Ltd. All rights reserved.
Cuchna, Jennifer W; Hoch, Matthew C; Hoch, Johanna M
2016-05-01
To synthesize the literature and perform a meta-analysis for both the interrater and intrarater reliability of the FMS™. Academic Search Complete, CINAHL, Medline and SportsDiscus databases were systematically searched from inception to March 2015. Studies were included if the primary purpose was to determine the interrater or intrarater reliability of the FMS™, assessed and scored all 7-items using the standard scoring criteria, provided a composite score and employed intraclass correlation coefficients (ICCs). Studies were excluded if reliability was not the primary aim, participants were injured at data collection, or a modified FMS™ or scoring system was utilized. Seven papers were included; 6 assessing interrater and 6 assessing intrarater reliability. There was moderate evidence in good interrater reliability with a summary ICC of 0.843 (95% CI = 0.640, 0.936; Q7 = 84.915, p < 0.0001). There was moderate evidence in good intrarater reliability with a summary ICC of 0.869 (95% CI = 0.785, 0.921; Q12 = 60.763, p < 0.0001). There was moderate evidence for both forms of reliability. The sensitivity assessments revealed this interpretation is stable and not influenced by any one study. Overall, the FMS™ is a reliable tool for clinical practice. Copyright © 2015 Elsevier Ltd. All rights reserved.
Singh, Amika S; Chinapaw, Mai J M; Uijtdewilligen, Léonie; Vik, Froydis N; van Lippevelde, Wendy; Fernández-Alvira, Juan M; Stomfai, Sarolta; Manios, Yannis; van der Sluijs, Maria; Terwee, Caroline; Brug, Johannes
2012-08-13
Insight in parental energy balance-related behaviours, their determinants and parenting practices are important to inform childhood obesity prevention. Therefore, reliable and valid tools to measure these variables in large-scale population research are needed. The objective of the current study was to examine the test-retest reliability and construct validity of the parent questionnaire used in the ENERGY-project, assessing parental energy balance-related behaviours, their determinants, and parenting practices among parents of 10-12 year old children. We collected data among parents (n = 316 in the test-retest reliability study; n = 109 in the construct validity study) of 10-12 year-old children in six European countries, i.e. Belgium, Greece, Hungary, the Netherlands, Norway, and Spain. Test-retest reliability was assessed using the intra-class correlation coefficient (ICC) and percentage agreement comparing scores from two measurements, administered one week apart. To assess construct validity, the agreement between questionnaire responses and a subsequent interview was assessed using ICC and percentage agreement.All but one item showed good to excellent test-retest reliability as indicated by ICCs > .60 or percentage agreement ≥ 75%. Construct validity appeared to be good to excellent for 92 out of 121 items, as indicated by ICCs > .60 or percentage agreement ≥ 75%. From the other 29 items, construct validity was moderate for 24 and poor for 5 items. The reliability and construct validity of the items of the ENERGY-parent questionnaire on multiple energy balance-related behaviours, their potential determinants, and parenting practices appears to be good. Based on the results of the validity study, we strongly recommend adapting parts of the ENERGY-parent questionnaire if used in future research.
Fieseler, Georg; Molitor, Thomas; Irlenbusch, Lars; Delank, Karl-Stefan; Laudner, Kevin G; Hermassi, Souhail; Schwesig, Rene
2015-12-01
To evaluate the intrarater reliability for examining active range of motion (ROM) and isometric strength of the shoulder and elbow among asymptomatic female team handball athletes and a control group using a manual goniometer and hand-held dynamometry (HHD). 22 female team handball athletes (age: 21.0 ± 3.7 years) and 25 volunteers (13 female, 12 male, age: 21.9 ± 1.24 years) participated to determine bilateral ROM for shoulder rotation and elbow flexion/extension, as well as isometric shoulder rotation and elbow flexion/extension strength. Subjects were assessed on two separate test sessions with 7 days between sessions. Relative (intraclass correlation coefficients (ICC) and standard error of measurement (SEM) reliability were calculated. Reliability for ROM and strength were good to excellent for both shoulders and groups (athletes: ICC = 0.94-0.97, SEM 1.07°-4.76 N, controls: ICC = 0.96-1.00, SEM = 0.00 N-4.48 N). Elbow measurements for both groups also showed good-to-excellent reliability (athletes: ICC = 0.79-0.97, SEM = 0.98°-5.94 N, controls: ICC = 0.87-1.00, SEM = 0.00 N-5.43 N). It is important to be able to reliably reproduce active ROM and isometric strength evaluations. Using a standardized testing position, goniometry and HHD are reliable instruments in the assessment of shoulder and elbow joint performance testing. We showed good-to-excellent reproducible results for male and female control subjects and female handball athletes, although the single parameters in ROM and strength were different for each group and between the shoulders and elbows.
Establishing the validity and reliability of the Project Talent Personality Inventory
Pozzebon, Julie; Damian, Rodica I.; Hill, Patrick L.; Lin, Yuchen; Lapham, Susan; Roberts, Brent W.
2013-01-01
Project Talent is a national longitudinal study that started in 1960. The original sample included over 440,000 students, which amounted to a 5% representative sample of high school students across the United States. Previous research has not yet established the validity and reliability of the personality measure used in this study, that is, the Project Talent Personality Inventory (PTPI). Given the potential interest and use of the PTPI in forthcoming research, the goals of the present paper were to establish (a) the construct and predictive validity and (b) the internal consistency and test-retest reliability of the PTPI. This information will be valuable to researchers who might be interested in using the PTPI to predict life course outcomes, such as mortality, occupational success, relationship success, and health. Study 1 found that the 10 sub-scales of the PTPI showed good internal consistency reliability, as well as good construct and predictive validity. With the use of several modern personality measures, we showed how the 10 PTPI scales can be mapped onto the Big Five personality traits, and we examined their relations with health, well-being, and life satisfaction outcomes. Study 2 found that the 10 PTPI scales showed good test-retest reliability. Together, these findings allow researchers to better understand and use the PTPI scales, as they are available in Project Talent. PMID:24399984
Mota-Anaya, Evelin; Yumpo-Cárdenas, Daniel; Alva-Bravo, Edmundo; Wright-Nunes, Julie; Mayta-Tristán, Percy
2016-08-08
Chronic kidney disease (CKD) affects 50 million people globally. Several studies show the importance of implementing interventions that enhance patients knowledge about their disease. In 2011 the Kidney Disease Knowledge Survey (KiKS) was developed: a questionnaire that assesses the specific knowledge about chronic kidney disease in pre-dialysis patients. To translate to Spanish, culturally adapt and validate the Kidney Disease Knowledge Survey questionnaire in a population of patients with pre-dialysis chronic kidney disease. We carried out a Spanish translation and cross-cultural adaptation of the Kidney Disease Knowledge Survey questionnaire. Subsequently, we determined its validity and reliability. We determined the validity through construct validity; and reliability by evaluating its internal consistency and its intra-observer reliability (test-retest). We found a good internal consistency (Kuder-Richardson = 0.85). The intra-observer reliability was measured by the intra-class correlation coefficient that yielded a value of 0.78 (95% CI: 0.5-1.0). This value indicated a good reproducibility; also, the mean difference of -1.1 test-retest SD 6.0 (p = 0.369) confirms this finding. The translated Spanish version of the Kidney Disease Knowledge Survey is acceptable and equivalent to the original version; it also has a good reliability, validity and reproducibility. Therefore, it can be used in a population of patients with pre-dialysis chronic kidney disease.
Kadioglu, Hasibe; Erol, Saime; Ergun, Ayse
2015-01-01
The purpose of this research was to examine the psychometric properties of the Turkish version of the situational self-efficacy scale for vegetable and fruit consumption in adolescents. This was a methodological study. The study was conducted in four public secondary schools in Istanbul, Turkey. Subjects were 1586 adolescents. Content and construct validity were assessed to test the validity of the scale. The reliability was assessed in terms of internal consistency and test-retest reliability. For confirmatory factor analysis, χ(2) statistics plus other fit indices were used, including the goodness-of-fit index, the adjusted goodness-of-fit index, the nonnormed fit index, the comparative fit index, the standardized root mean residual, and the root mean square error of approximation. Pearson's correlation was used for test-retest reliability and item total correlation. The internal consistency was assessed by using Cronbach α. Confirmatory factor analysis strongly supported the three-component structure representing positive social situations (α = .81), negative effect situations (α = .93), and difficult situations (α = .78). Psychometric analyses of the Turkish version of the situational self-efficacy scale indicate high reliability and good content and construct validity. Researchers and health professionals will find it useful to employ the Turkish situational self-efficacy scale in evaluating situational self-efficacy for fruit and vegetable consumption in Turkish adolescents.
Bazo-Alvarez, Juan Carlos; Bazo-Alvarez, Oscar Alfredo; Aguila, Jeins; Peralta, Frank; Mormontoy, Wilfredo; Bennett, Ian M
2016-01-01
Our aim was to evaluate the psychometric properties of the FACES-III among Peruvian high school students. This is a psychometric cross-sectional study. A probabilistic sampling was applied, defined by three stages: stratum one (school), stratum two (grade) and cluster (section). The participants were 910 adolescent students of both sexes, between 11 and 18 years of age. The instrument was also the object of study: the Olson's FACES-III. The analysis included a review of the structure / construct validity of the measure by factor analysis and assessment of internal consistency (reliability). The real-cohesion scale had moderately high reliability (Ω=.85) while the real-flexibility scale had moderate reliability (Ω=.74). The reliability found for the ideal-cohesion was moderately high (Ω=.89) like for the scale of ideal-flexibility (Ω=.86). Construct validity was confirmed by the goodness of fit of a two factor model (cohesion and flexibility) with 10 items each [Adjusted goodness of fit index (AGFI) = 0.96; Expected Cross Validation Index (ECVI) = 0.87; Normed fit index (NFI) = 0.93; Goodness of fit index (GFI) = 0.97; Root mean square error of approximation (RMSEA) = 0.06]. FACES-III has sufficient reliability and validity to be used in Peruvian adolescents for the purpose of group or individual assessment.
Validating the Center for Epidemiological Studies Depression Scale for Children in Rwanda
Betancourt, Theresa; Scorza, Pamela; Meyers-Ohki, Sarah; Mushashi, Christina; Kayiteshonga, Yvonne; Binagwaho, Agnes; Stulac, Sara; Beardslee, William R.
2017-01-01
Objective We assessed the validity of the Center for Epidemiological Studies Depression Scale for Children (CES-DC) as a screen for depression in Rwandan children and adolescents. Although the CES-DC is widely used for depression screening in high-income countries, its validity in low-income and culturally diverse settings, including sub-Saharan Africa, is unknown. Method The CES-DC was selected based on alignment with local expressions of depression-like problems in Rwandan children and adolescents. To examine criterion validity, we compared CES-DC scores to depression diagnoses on a structured diagnostic interview, the Mini International Neuropsychiatric Interview for Children (MINI KID), in a sample of 367 Rwandan children and adolescents aged 10 through 17 years. Caregiver and child or adolescent self-reports endorsing the presence of local depression-like problems agahinda kenshi (persistent sorrow) and kwiheba (severe hopelessness) were also examined for agreement with MINI KID diagnosis. Results The CES-DC exhibited good internal reliability (α = .86) and test-retest reliability (r = .85). The area under the receiver operating characteristic curve for the CES-DC was 0.825 when compared to MINI KID diagnoses, indicating a strong ability to distinguish between depressed and nondepressed children and adolescents in Rwanda. A cut point of ≥ 30 corresponded with a sensitivity of 81.9% and a specificity of 71.9% in this referred sample. MINI KID diagnosis was well aligned with local expressions of depression-like problems. Conclusion The CES-DC demonstrates good psychometric properties for clinical screening and evaluation in Rwanda, and should be considered for use in this and other low-resource settings. Population samples are needed to determine a generalizable cut point in nonreferred samples. PMID:23200285
Assessment of the amount of tooth wear on dental casts and intra-oral photographs.
Wetselaar, P; Wetselaar-Glas, M J M; Koutris, M; Visscher, C M; Lobbezoo, F
2016-08-01
Tooth wear is a multifactorial condition, leading to the loss of dental hard tissues. Many grading scales are available to assess the amount of tooth wear, one of which is the tooth wear evaluation system (TWES). A grading scale can be used chairside, on casts and on photographs. The aim was to test whether the grading scales of the TWES, used on casts and on photographs, resulted in comparable scores. In addition, it was tested whether these scales can be used to assess tooth wear reliably on photographs. Of 75 tooth wear patients, sets of casts and series of photographs were obtained and graded. Comparison of the grading on casts and on photographs revealed equal median values and percentiles for both occlusal/incisal grading and non-occlusal/non-incisal grading. The grading on casts and on photographs showed a high correlation for the occlusal/incisal grading and a low correlation for the non-occlusal/non-incisal grading (Spearman's rho = 0·74 and rho = 0·47; P < 0·001). Concerning the grading on photographs, the interexaminer reliability was fair-to-good (ICC = 0·41 to ICC = 0·55) while the intra-examiner reliability was fair-to-good to excellent (ICC = 0·68 to ICC = 0·86) for the occlusal/incisal grading. For the non-occlusal/non-incisal grading, the interexaminer reliability was poor to fair-to-good (ICC = 0·22 to ICC = 0·59), while the intra-examiner reliability was fair-to-good to excellent (ICC = 0·64 to ICC = 0·82). It was concluded that the scores obtained with the grading scales of the TWES on casts and on photographs are comparable. The grading scales can be used in a reliable way on photographs, which is especially the case for occlusal/incisal grading. © 2016 John Wiley & Sons Ltd.
ERIC Educational Resources Information Center
Barbu, Otilia C.; Levine-Donnerstein, Deborah; Marx, Ronald W.; Yaden, David B., Jr.
2013-01-01
This study examined reliability and validity of the Devereux Early Childhood Assessment (DECA), based on samples of parents and teachers' ratings of 1,145 entering kindergartners in the Southwest. Confirmatory factor analysis showed that DECA presented good reliability and validity for manifest variables, corroborating previous findings. Three…
Ramírez-Vélez, Robinson; Cruz-Salazar, Sandra Milena; Martínez, Myriam; Cadore, Eduardo L; Alonso-Martinez, Alicia M; Correa-Bautista, Jorge E; Izquierdo, Mikel; Ortega, Francisco B; García-Hermoso, Antonio
2017-01-01
There is a lack of instruments and studies written in Spanish evaluating physical fitness, impeding the determination of the current status of this important health indicator in the Latin population, especially in Colombia. The aim of the study was two-fold: to examine the validity of the International Fitness Scale (IFIS) with a population-based sample of schoolchildren from Bogota, Colombia and to examine the reliability of the IFIS with children and adolescents from Engativa, Colombia. The sample comprised 1,873 Colombian youths (54.5% girls) aged 9-17.9 years. We measured their adiposity markers (waist-to-height ratio, skinfold thickness, percentage of body fat and body mass index), blood pressure, lipids profile, fasting glucose, and physical fitness level (self-reported and measured). A validated cardiometabolic risk index score was also used. An age- and sex-matched subsample of 229 schoolchildren who were not originally included in the sample completed the IFIS twice for reliability purposes. Our data suggest that both measured and self-reported overall physical fitness levels were inversely associated with percentage of body fat indicators and the cardiometabolic risk index score. Overall, schoolchildren who self-reported "good" or "very good" fitness had better measured fitness levels than those who reported "very poor/poor" fitness (all p < 0.001). The test-retest reliability of the IFIS items was also good, with an average weighted kappa of 0.811. Our findings suggest that self-reported fitness, as assessed by the IFIS, is a valid, reliable, and health-related measure. Furthermore, it can be a good alternative for future use in large studies with Latin schoolchildren from Colombia.
Goetz, Katja; Hasse, Philipp; Szecsenyi, Joachim; Campbell, Stephen M
2016-04-01
The consideration of organisational aspects, such as shared goals and clear communication, within the health care team is important to ensure good quality care. In primary health care, the instrument Survey of Organizational Attributes for Primary Care (SOAPC) is available to measure organisational attributes of care. However, there is no instrument available for dental care. The aim of the present study was to investigate psychometric properties and test-retest reliability of the version of SOAPC adapted for dental care, namely the Survey of Organizational Attributes in Dental Care (SOADC). The SOADC consists of 21 items in the following four subscales: communication; decision making; stress/chaos; and history of change. Convergent construct validity was measured using the job satisfaction scale. A total of 287 dental-care practices were asked to participate in the validation study. Psychometric properties and test-retest reliability were observed. A total of 43 dental-care practices responded to the survey. At baseline, 178 dental-care staff completed the questionnaire, and 4 weeks later 138 did so. Internal consistency, measured by Cronbach's alpha, was 0.718 or higher in the subscales. The test-retest reliability for each subscale and the overall SOADC score demonstrated good correlations over the 4-week test-retest interval, except for 'history of change'. A strong correlation with the aggregated job-satisfaction scale showed high convergent construct validity of SOADC. The consideration of organisational aspects from the perspective of dental-care teams is important for providing good quality of care. The SOADC is a reliable instrument with good psychometric properties and is suitable for the evaluation of organisational attributes in dental-care practices. © 2015 FDI World Dental Federation.
Validity and reliability of a scale to measure genital body image.
Zielinski, Ruth E; Kane-Low, Lisa; Miller, Janis M; Sampselle, Carolyn
2012-01-01
Women's body image dissatisfaction extends to body parts usually hidden from view--their genitals. Ability to measure genital body image is limited by lack of valid and reliable questionnaires. We subjected a previously developed questionnaire, the Genital Self Image Scale (GSIS) to psychometric testing using a variety of methods. Five experts determined the content validity of the scale. Then using four participant groups, factor analysis was performed to determine construct validity and to identify factors. Further construct validity was established using the contrasting groups approach. Internal consistency and test-retest reliability was determined. Twenty one of 29 items were considered content valid. Two items were added based on expert suggestions. Factor analysis was undertaken resulting in four factors, identified as Genital Confidence, Appeal, Function, and Comfort. The revised scale (GSIS-20) included 20 items explaining 59.4% of the variance. Women indicating an interest in genital cosmetic surgery exhibited significantly lower scores on the GSIS-20 than those who did not. The final 20 item scale exhibited internal reliability across all sample groups as well as test-retest reliability. The GSIS-20 provides a measure of genital body image demonstrating reliability and validity across several populations of women.
NASA Technical Reports Server (NTRS)
Gerke, R. David; Sandor, Mike; Agarwal, Shri; Moor, Andrew F.; Cooper, Kim A.
1999-01-01
This paper presents viewgraphs on Plastic Encapsulated Microcircuits (PEMs). Different approaches are addressed to ensure good performance and reliability of PEMs. The topics include: 1) Mitigating Risk; and 2) Program results.
Inter-arch digital model vs. manual cast measurements: Accuracy and reliability.
Kiviahde, Heikki; Bukovac, Lea; Jussila, Päivi; Pesonen, Paula; Sipilä, Kirsi; Raustia, Aune; Pirttiniemi, Pertti
2017-06-28
The purpose of this study was to evaluate the accuracy and reliability of inter-arch measurements using digital dental models and conventional dental casts. Thirty sets of dental casts with permanent dentition were examined. Manual measurements were done with a digital caliper directly on the dental casts, and digital measurements were made on 3D models by two independent examiners. Intra-class correlation coefficients (ICC), a paired sample t-test or Wilcoxon signed-rank test, and Bland-Altman plots were used to evaluate intra- and inter-examiner error and to determine the accuracy and reliability of the measurements. The ICC values were generally good for manual and excellent for digital measurements. The Bland-Altman plots of all the measurements showed good agreement between the manual and digital methods and excellent inter-examiner agreement using the digital method. Inter-arch occlusal measurements on digital models are accurate and reliable and are superior to manual measurements.
Evaluation of high fidelity patient simulator in assessment of performance of anaesthetists.
Weller, J M; Bloch, M; Young, S; Maze, M; Oyesola, S; Wyner, J; Dob, D; Haire, K; Durbridge, J; Walker, T; Newble, D
2003-01-01
There is increasing emphasis on performance-based assessment of clinical competence. The High Fidelity Patient Simulator (HPS) may be useful for assessment of clinical practice in anaesthesia, but needs formal evaluation of validity, reliability, feasibility and effect on learning. We set out to assess the reliability of a global rating scale for scoring simulator performance in crisis management. Using a global rating scale, three judges independently rated videotapes of anaesthetists in simulated crises in the operating theatre. Five anaesthetists then independently rated subsets of these videotapes. There was good agreement between raters for medical management, behavioural attributes and overall performance. Agreement was high for both the initial judges and the five additional raters. Using a global scale to assess simulator performance, we found good inter-rater reliability for scoring performance in a crisis. We estimate that two judges should provide a reliable assessment. High fidelity simulation should be studied further for assessing clinical performance.
Spector, Aimee; Hebditch, Molly; Stoner, Charlotte R; Gibbor, Luke
2016-09-01
The ability to identify biological, social, and psychological issues for people with dementia is an important skill for healthcare professionals. Therefore, valid and reliable measures are needed to assess this ability. This study involves the development of a vignette style measure to capture the extent to which health professionals use "Biopsychosocial" thinking in dementia care (VIG-Dem), based on the framework of the model developed by Spector and Orrell (2010). The development process consisted of Phase 1: Developing and refining the vignettes; Phase 2: Field testing (N = 9), and Phase 3: A pilot study to assess reliability and validity (N = 131). The VIG-Dem, consisting of two vignettes with open-ended questions and a standardized scoring scheme, was developed. Evidence for the good inter-rater reliability, convergent validity, and test-retest reliability were established. The VIG-Dem has good psychometric properties and may provide a useful tool in dementia care research and practice.
Li, Sikun; Wang, Xiangzhao; Su, Xianyu; Tang, Feng
2012-04-20
This paper theoretically discusses modulus of two-dimensional (2D) wavelet transform (WT) coefficients, calculated by using two frequently used 2D daughter wavelet definitions, in an optical fringe pattern analysis. The discussion shows that neither is good enough to represent the reliability of the phase data. The differences between the two frequently used 2D daughter wavelet definitions in the performance of 2D WT also are discussed. We propose a new 2D daughter wavelet definition for reliability-guided phase unwrapping of optical fringe pattern. The modulus of the advanced 2D WT coefficients, obtained by using a daughter wavelet under this new daughter wavelet definition, includes not only modulation information but also local frequency information of the deformed fringe pattern. Therefore, it can be treated as a good parameter that represents the reliability of the retrieved phase data. Computer simulation and experimentation show the validity of the proposed method.
Rapid and Reliable Binding Affinity Prediction of Bromodomain Inhibitors: A Computational Study
2016-01-01
Binding free energies of bromodomain inhibitors are calculated with recently formulated approaches, namely ESMACS (enhanced sampling of molecular dynamics with approximation of continuum solvent) and TIES (thermodynamic integration with enhanced sampling). A set of compounds is provided by GlaxoSmithKline, which represents a range of chemical functionality and binding affinities. The predicted binding free energies exhibit a good Spearman correlation of 0.78 with the experimental data from the 3-trajectory ESMACS, and an excellent correlation of 0.92 from the TIES approach where applicable. Given access to suitable high end computing resources and a high degree of automation, we can compute individual binding affinities in a few hours with precisions no greater than 0.2 kcal/mol for TIES, and no larger than 0.34 and 1.71 kcal/mol for the 1- and 3-trajectory ESMACS approaches. PMID:28005370
Amendola, Fernanda; Alvarenga, Márcia Regina Martins; Latorre, Maria do Rosário Dias de Oliveira; Oliveira, Maria Amélia de Campos
2014-02-01
This exploratory, descriptive, cross-sectional, and quantitative study aimed to develop and validate an index of family vulnerability to disability and dependence (FVI-DD). This study was adapted from the Family Development Index, with the addition of social and health indicators of disability and dependence. The instrument was applied to 248 families in the city of Sao Paulo, followed by exploratory factor analysis. Factor validation was performed using the concurrent and discriminant validity of the Lawton scale and Katz Index. The descriptive level adopted for the study was p < 0.05. The final vulnerability index comprised 50 questions classified into seven factors contemplating social and health dimensions, and this index exhibited good internal consistency (Cronbach's alpha = 0.82). FVI-DD was validated using both the Lawton scale and Katz Index. We conclude that FVI-DD can accurately and reliably assess family vulnerability to disability and dependence.
Sarı, Ahmet; Alkan, Cemil; Biçer, Alper
2016-05-01
In this study, PMMA/heneicosane (C21) and PMMA/octacosane (C28) micro-nano capsules were fabricated via emulsion polymerisation method. The chemical structures of the fabricated capsules were verified with the FT-IR spectroscopy analysis. The results of POM, SEM and PSD analysis indicated that most of the capsules were consisted of micro/nano-sized spheres with compact surface. The DSC measurements showed that the capsules had melting temperature in the range of about 39-60 °C and latent heat energy storage capacity in the range of about 138-152 J/g. The results of TGA showed that sublimit temperature values regarding the first degradation steps of both capsules were quite over the phase change or working temperatures of encapsulated paraffins. The thermal cycling test exhibited that the capsules had good thermal reliability and chemical stability. Additionally, the prepared capsules had reasonably high thermal conductivity.
Adapting the academic motivation scale for use in pre-tertiary mathematics classrooms
NASA Astrophysics Data System (ADS)
Lim, Siew Yee; Chapman, Elaine
2015-09-01
The Academic Motivation Scale ( ams) is a comprehensive and widely used instrument for assessing motivation based on the self-determination theory. Currently, no such comprehensive instrument exists to assess the different domains of motivation (stipulated by the self-determination theory) in mathematics education at the pre-tertiary level (grades 11 and 12) in Asia. This study adapted the ams for this use and assessed the properties of the adapted instrument with 1610 students from Singapore. Exploratory and confirmatory factor analyses indicated a five-factor structure for the modified instrument (the three original ams intrinsic subscales collapsed into a single factor). Additionally, the modified instrument exhibited good internal consistency (mean α = .88), and satisfactory test-retest reliability over a 1-month interval (mean r xx = .73). The validity of the modified ams was further demonstrated through correlational analyses among scores on its subscales, and with scores on other instruments measuring mathematics attitudes, anxiety and achievement.
Adkins, Jennifer W; Weathers, Frank W; McDevitt-Murphy, Meghan; Daniels, Jennifer B
2008-12-01
In this study psychometric properties of seven self-report measures of posttraumatic stress disorder (PTSD) were compared. The seven scales evaluated were the Davidson Trauma Scale (DTS), the PTSD Checklist (PCL), the Posttraumatic Stress Diagnostic Scale (PDS), the Civilian Mississippi Scale (CMS), the Impact of Event Scale-Revised (IES-R), the Penn Inventory for Posttraumatic Stress Disorder (Penn), and the PK scale of the MMPI-2 (PK). Participants were 239 (79 male and 160 female) trauma-exposed undergraduates. All seven measures exhibited good test-retest reliability and internal consistency. The PDS, PCL and DTS demonstrated the best convergent validity; the IES-R, PDS, and PCL demonstrated the best discriminant validity; and the PDS, PCL, and IES-R demonstrated the best diagnostic utility. Overall, results most strongly support the use of the PDS and the PCL for the assessment of PTSD in this population.
Socioeconomic variation, number competence, and mathematics learning difficulties in young children.
Jordan, Nancy C; Levine, Susan C
2009-01-01
As a group, children from disadvantaged, low-income families perform substantially worse in mathematics than their counterparts from higher-income families. Minority children are disproportionately represented in low-income populations, resulting in significant racial and social-class disparities in mathematics learning linked to diminished learning opportunities. The consequences of poor mathematics achievement are serious for daily functioning and for career advancement. This article provides an overview of children's mathematics difficulties in relation to socioeconomic status (SES). We review foundations for early mathematics learning and key characteristics of mathematics learning difficulties. A particular focus is the delays or deficiencies in number competencies exhibited by low-income children entering school. Weaknesses in number competence can be reliably identified in early childhood, and there is good evidence that most children have the capacity to develop number competence that lays the foundation for later learning.
Antiresonant reflecting guidance mechanism in hollow-core fiber for gas pressure sensing.
Hou, Maoxiang; Zhu, Feng; Wang, Ying; Wang, Yiping; Liao, Changrui; Liu, Shen; Lu, Peixiang
2016-11-28
A gas pressure sensor based on an antiresonant reflecting guidance mechanism in a hollow-core fiber (HCF) with an open microchannel is experimentally demonstrated for gas pressure sensing. The microchannel was created on the ring cladding of the HCF by femtosecond laser drilling to provide an air-core pressure equivalent to the external environment. The HCF cladding functions as an antiresonant reflecting waveguide, which induces sharp periodic lossy dips in the transmission spectrum. The proposed sensor exhibits a high pressure sensitivity of 3.592 nm/MPa and a low temperature cross-sensitivity of 7.5 kPa/°C. Theoretical analysis indicates that the observed high gas pressure sensitivity originates from the pressure induced refractive index change of the air in the hollow-core. The good operation durability and fabrication simplicity make the device an attractive candidate for reliable and highly sensitive gas pressure measurement in harsh environments.
A strain-absorbing design for tissue-machine interfaces using a tunable adhesive gel.
Lee, Sungwon; Inoue, Yusuke; Kim, Dongmin; Reuveny, Amir; Kuribara, Kazunori; Yokota, Tomoyuki; Reeder, Jonathan; Sekino, Masaki; Sekitani, Tsuyoshi; Abe, Yusuke; Someya, Takao
2014-12-19
To measure electrophysiological signals from the human body, it is essential to establish stable, gentle and nonallergic contacts between the targeted biological tissue and the electrical probes. However, it is difficult to form a stable interface between the two for long periods, especially when the surface of the biological tissue is wet and/or the tissue exhibits motion. Here we resolve this difficulty by designing and fabricating smart, stress-absorbing electronic devices that can adhere to wet and complex tissue surfaces and allow for reliable, long-term measurements of vital signals. We demonstrate a multielectrode array, which can be attached to the surface of a rat heart, resulting in good conformal contact for more than 3 h. Furthermore, we demonstrate arrays of highly sensitive, stretchable strain sensors using a similar design. Ultra-flexible electronics with enhanced adhesion to tissue could enable future applications in chronic in vivo monitoring of biological signals.
Müller, Helge H.O.; Reike, Mareen; Grosse-Holz, Simon; Röther, Mareike; Lücke, Caroline; Philipsen, Alexandra; Kornhuber, Johannes; Grömer, Teja W.
2017-01-01
Electroconvulsive therapy (ECT) is effective in the treatment of treatment-resistant major depression. The fear of cognitive impairment after ECT often deters patients from choosing this treatment option. There is little reliable information regarding the effects of ECT on overall cognitive performance, while short-term memory deficits are well known but not easy to measure within clinical routines. In this pilot study, we examined ECT recipients’ pre- and post-treatment performances on a digital ascending number tapping test. We found that cognitive performance measures exhibited good reproducibility in individual patients and that ECT did not significantly alter cognitive performance up to 2 hours after this therapy was applied. Our results can help patients and physicians make decisions regarding the administration of ECT. Digital measurements are recommended, especially when screening for the most common side effects on cognitive performance and short-term memory. PMID:28748058
Löffler, Frank E.; Tiedje, James M.; Sanford, Robert A.
1999-01-01
Measurements of the hydrogen consumption threshold and the tracking of electrons transferred to the chlorinated electron acceptor (fe) reliably detected chlororespiratory physiology in both mixed cultures and pure cultures capable of using tetrachloroethene, cis-1,2-dichloroethene, vinyl chloride, 2-chlorophenol, 3-chlorobenzoate, 3-chloro-4-hydroxybenzoate, or 1,2-dichloropropane as an electron acceptor. Hydrogen was consumed to significantly lower threshold concentrations of less than 0.4 ppmv compared with the values obtained for the same cultures without a chlorinated compound as an electron acceptor. The fe values ranged from 0.63 to 0.7, values which are in good agreement with theoretical calculations based on the thermodynamics of reductive dechlorination as the terminal electron-accepting process. In contrast, a mixed methanogenic culture that cometabolized 3-chlorophenol exhibited a significantly lower fe value, 0.012. PMID:10473415
Signal honesty and predation risk among a closely related group of aposematic species
María Arenas, Lina; Walter, Dominic; Stevens, Martin
2015-01-01
Many animals have bright colours to warn predators that they have defences and are not worth attacking. However, it remains unclear whether the strength of warning colours reliably indicate levels of defence. Few studies have unambiguously established if warning signals are honest, and have rarely considered predator vision or conspicuousness against the background. Importantly, little data exists either on how differences in signal strength translate into survival advantages. Ladybirds exhibit impressive variation in coloration both among and within species. Here we demonstrate that different levels of toxicity exist among and within ladybird species, and that signal contrast against the background is a good predictor of toxicity, showing that the colours are honest signals. Furthermore, field experiments with ladybird models created with regards to predator vision show that models with lower conspicuousness were attacked more frequently. This provides one of the most comprehensive studies on signal honesty in warning coloration to date. PMID:26046332
Müller, Helge H O; Reike, Mareen; Grosse-Holz, Simon; Röther, Mareike; Lücke, Caroline; Philipsen, Alexandra; Kornhuber, Johannes; Grömer, Teja W
2017-03-22
Electroconvulsive therapy (ECT) is effective in the treatment of treatment-resistant major depression. The fear of cognitive impairment after ECT often deters patients from choosing this treatment option. There is little reliable information regarding the effects of ECT on overall cognitive performance, while short-term memory deficits are well known but not easy to measure within clinical routines. In this pilot study, we examined ECT recipients' pre- and post-treatment performances on a digital ascending number tapping test. We found that cognitive performance measures exhibited good reproducibility in individual patients and that ECT did not significantly alter cognitive performance up to 2 hours after this therapy was applied. Our results can help patients and physicians make decisions regarding the administration of ECT. Digital measurements are recommended, especially when screening for the most common side effects on cognitive performance and short-term memory.
Individual significance of olfaction: development of a questionnaire.
Croy, Ilona; Buschhüter, Dorothee; Seo, Han-Seok; Negoias, Simona; Hummel, Thomas
2010-01-01
Clinical experience shows that the individual significance of olfactory function varies between subjects. In order to estimate these individual differences we developed a questionnaire to study the subjective importance of the sense of smell. Questions were arranged within three subscales: association with olfactory sensations, application of the sense of smell, and the readiness to draw consequences from the olfactory perception. The questionnaire was shown to be time efficient, suitable for normosmic subjects and patients with hyposmia or anosmia. It exhibited a good internal reliability (Cronbach's Alpha = 0.77). First results in 123 subjects indicate that the subjective importance of the sense of smell stays at the same level throughout life-span despite of a decreased olfactory sensitivity. Furthermore, women reported a higher importance of olfaction. It is hoped that this questionnaire will contribute to clarify, for example, cross-cultural differences in the perception of odours.
Developing and testing the CHORDS: Characteristics of Responsible Drinking Survey.
Barry, Adam E; Goodson, Patricia
2011-01-01
Report on the development and psychometric testing of a theoretically and evidence-grounded instrument, the Characteristics of Responsible Drinking Survey (CHORDS). Instrument subjected to four phases of pretesting (cognitive validity, cognitive and motivational qualities, pilot test, and item evaluation) and a final posttest implementation. Large public university in Texas. Randomly selected convenience sample (n = 729) of currently enrolled students. This 78-item questionnaire measures individuals' responsible drinking beliefs, motivations, intentions, and behaviors. Cronbach α, split-half reliability, principal components analysis and Spearman ρ were conducted to investigate reliability, stability, and validity. Measures in the CHORDS exhibited high internal consistency reliability and strong correlations of split-half reliability. Factor analyses indicated five distinct scales were present, as proposed in the theoretical model. Subscale composite scores also exhibited a correlation to alcohol consumption behaviors, indicating concurrent validity. The CHORDS represents the first instrument specifically designed to assess responsible drinking beliefs and behaviors. It was found to elicit valid and reliable data among a college student sample. This instrument holds much promise for practitioners who desire to empirically investigate dimensions of responsible drinking.
Tabrizi, Yousef Moghadas; Zangiabadi, Nasser; Mazhari, Shahrzad; Zolala, Farzaneh
2013-01-01
Objective Motor imagery (MI) has been recently considered as an adjunct to physical rehabilitation in patients with multiple sclerosis (MS). It is necessary to assess MI abilities and benefits in patients with MS by using a reliable tool. The Kinesthetic and Visual Imagery Questionnaire (KVIQ) was recently developed to assess MI ability in patients with stroke and other disabilities. Considering the different underlying pathologies, the present study aimed to examine the validity and reliability of the KVIQ in MS patients. Method Fifteen MS patients were assessed using the KVIQ in 2 sessions (5-14days apart) by the same examiner. In the second session, the participants also completed a revised MI questionnaire (MIQ-R) as the gold standard. Intra-class correlation coefficients (ICCs) were measured to determine test-retest reliability. Spearman's correlation analysis was performed to assess concurrent validity with the MIQ-R. Furthermore, the internal consistency (Cronbach's alpha) and factorial structure of the KVIQ were studied. Results The test-retest reliability for the KVIQ was good (ICCs: total KVIQ=0.89, visual KVIQ=0.85, and kinesthetic KVIQ=0.93), and the concurrent validity between the KVIQ and MIQ-R was good (r=0.79). The KVIQ had good internal consistency, with high Cronbach's alpha (alpha=0.84). Factorial analysis showed the bi-factorial structure of the KVIQ, which was explained by visual=57.6% and kinesthetic=32.4%. Conclusions The results of the present study revealed that the KVIQ is a valid and reliable tool for assessing MI in MS patients. PMID:24271091
Tabrizi, Yousef Moghadas; Zangiabadi, Nasser; Mazhari, Shahrzad; Zolala, Farzaneh
2013-01-01
Motor imagery (MI) has been recently considered as an adjunct to physical rehabilitation in patients with multiple sclerosis (MS). It is necessary to assess MI abilities and benefits in patients with MS by using a reliable tool. The Kinesthetic and Visual Imagery Questionnaire (KVIQ) was recently developed to assess MI ability in patients with stroke and other disabilities. Considering the different underlying pathologies, the present study aimed to examine the validity and reliability of the KVIQ in MS patients. Fifteen MS patients were assessed using the KVIQ in 2 sessions (5-14 days apart) by the same examiner. In the second session, the participants also completed a revised MI questionnaire (MIQ-R) as the gold standard. Intra-class correlation coefficients (ICCs) were measured to determine test-retest reliability. Spearman's correlation analysis was performed to assess concurrent validity with the MIQ-R. Furthermore, the internal consistency (Cronbach's alpha) and factorial structure of the KVIQ were studied. The test-retest reliability for the KVIQ was good (ICCs: total KVIQ=0.89, visual KVIQ=0.85, and kinesthetic KVIQ=0.93), and the concurrent validity between the KVIQ and MIQ-R was good (r=0.79). The KVIQ had good internal consistency, with high Cronbach's alpha (alpha=0.84). Factorial analysis showed the bi-factorial structure of the KVIQ, which was explained by visual=57.6% and kinesthetic=32.4%. The results of the present study revealed that the KVIQ is a valid and reliable tool for assessing MI in MS patients.
Jensen, K K; Kjaer, M; Jorgensen, L N
2016-12-01
To determine the reliability of measurements obtained by the Good Strength dynamometer, determining isometric abdominal wall and back muscle strength in patients with ventral incisional hernia (VIH) and healthy volunteers with an intact abdominal wall. Ten patients with VIH and ten healthy volunteers with an intact abdominal wall were each examined twice with a 1 week interval. Examination included the assessment of truncal flexion and extension as measured with the Good Strength dynamometer, the completion of the International Physical Activity Questionnaire (IPAQ) and the self-assessment of truncal strength on a visual analogue scale (SATS). The test-retest reliability of truncal flexion and extension was assessed by interclass correlation coefficient (ICC), and Bland and Altman graphs. Finally, correlations between truncal strength, and IPAQ and SATS were examined. Truncal flexion and extension showed excellent test-retest reliability for both patients with VIH (ICC 0.91 and 0.99) and healthy controls (ICC 0.97 and 0.96). Bland and Altman plots showed that no systematic bias was present for neither truncal flexion nor extension when assessing reliability. For patients with VIH, no significant correlations between objective measures of truncal strength and IPAQ or SATS were found. For healthy controls, both truncal flexion (τ 0.58, p = 0.025) and extension (τ 0.58, p = 0.025) correlated significantly with SATS, while no other significant correlation between truncal strength measures and IPAQ was found. The Good Strength dynamometer provided a reliable, low-cost measure of truncal flexion and extension in patients with VIH.
López-Pina, José Antonio; Sánchez-Meca, Julio; López-López, José Antonio; Marín-Martínez, Fulgencio; Núñez-Núñez, Rosa Ma; Rosa-Alcázar, Ana I; Gómez-Conesa, Antonia; Ferrer-Requena, Josefa
2015-01-01
The Yale-Brown Obsessive-Compulsive Scale for children and adolescents (CY-BOCS) is a frequently applied test to assess obsessive-compulsive symptoms. We conducted a reliability generalization meta-analysis on the CY-BOCS to estimate the average reliability, search for reliability moderators, and propose a predictive model that researchers and clinicians can use to estimate the expected reliability of the CY-BOCS scores. A total of 47 studies reporting a reliability coefficient with the data at hand were included in the meta-analysis. The results showed good reliability and a large variability associated to the standard deviation of total scores and sample size.
The reliability of a quality appraisal tool for studies of diagnostic reliability (QAREL).
Lucas, Nicholas; Macaskill, Petra; Irwig, Les; Moran, Robert; Rickards, Luke; Turner, Robin; Bogduk, Nikolai
2013-09-09
The aim of this project was to investigate the reliability of a new 11-item quality appraisal tool for studies of diagnostic reliability (QAREL). The tool was tested on studies reporting the reliability of any physical examination procedure. The reliability of physical examination is a challenging area to study given the complex testing procedures, the range of tests, and lack of procedural standardisation. Three reviewers used QAREL to independently rate 29 articles, comprising 30 studies, published during 2007. The articles were identified from a search of relevant databases using the following string: "Reproducibility of results (MeSH) OR reliability (t.w.) AND Physical examination (MeSH) OR physical examination (t.w.)." A total of 415 articles were retrieved and screened for inclusion. The reviewers undertook an independent trial assessment prior to data collection, followed by a general discussion about how to score each item. At no time did the reviewers discuss individual papers. Reliability was assessed for each item using multi-rater kappa (κ). Multi-rater reliability estimates ranged from κ = 0.27 to 0.92 across all items. Six items were recorded with good reliability (κ > 0.60), three with moderate reliability (κ = 0.41 - 0.60), and two with fair reliability (κ = 0.21 - 0.40). Raters found it difficult to agree about the spectrum of patients included in a study (Item 1) and the correct application and interpretation of the test (Item 10). In this study, we found that QAREL was a reliable assessment tool for studies of diagnostic reliability when raters agreed upon criteria for the interpretation of each item. Nine out of 11 items had good or moderate reliability, and two items achieved fair reliability. The heterogeneity in the tests included in this study may have resulted in an underestimation of the reliability of these two items. We discuss these and other factors that could affect our results and make recommendations for the use of QAREL.
Lee, Chin-Pang; Chiu, Yu-Wen; Chu, Chun-Lin; Chen, Yu; Jiang, Kun-Hao; Chen, Jiun-Liang; Chen, Ching-Yen
2016-12-01
The aging males' symptoms (AMS) scale is an instrument used to determine the health-related quality of life in adult and elderly men. The purpose of this study was to synthesize internal consistency (Cronbach's alpha) and test-retest reliability for the AMS scale and its three subscales. Of the 123 studies reviewed, 12 provided alpha coefficients which were then used in the meta-analyses of internal consistency. Seven of the 12 included studies provided test-retest coefficients, and these were used in the meta-analyses of test-retest reliability. The AMS scale had excellent internal consistency [α = 0.89 (95% CI 0.88-0.90)]; the mean alpha estimates across the AMS subscales ranged from 0.79 to 0.82. The AMS scale also had good test-retest reliability [r = 0.85 (95% CI 0.82-0.88]; the test-retest reliability coefficients of the AMS subscales ranged from 0.76 to 0.83. There was significant heterogeneity among the included studies. The AMS scale and the three subscales had fairly good internal consistency and test-retest reliability. Future psychometric studies of the AMS scale should report important characteristics of the participants, details of item scores, and test-retest reliability.
Testing the reliability of the Fall Risk Screening Tool in an elderly ambulatory population.
Fielding, Susan J; McKay, Michael; Hyrkas, Kristiina
2013-11-01
To identify and test the reliability of a fall risk screening tool in an ambulatory outpatient clinic. The Fall Risk Screening Tool (Albert Lea Medical Center, MN, USA) was scripted for an interview format. Two interviewers separately screened a convenience sample of 111 patients (age ≥ 65 years) in an ambulatory outpatient clinic in a northeastern US city. The interviewers' scoring of fall risk categories was similar. There was good internal consistency (Cronbach's α = 0.834-0.889) and inter-rater reliability [intra-class correlation coefficients (ICC) = 0.824-0.881] for total, Risk Factor and Client's Health Status subscales. The Physical Environment scores indicated acceptable internal consistency (Cronbach's α = 0.742) and adequate reliability (ICC = 0.688). Two Physical Environment items (furniture and medical equipment condition) had low reliabilities [Kappa (K) = 0.323, P = 0.08; K = -0.078, P = 0.648), respectively. The scripted Fall Risk Screening Tool demonstrated good reliability in this sample. Rewording two Physical Environment items will be considered. A reliable instrument such as the scripted Fall Risk Screening Tool provides a standardised assessment for identifying high fall risk patients. This tool is especially useful because it assesses personal, behavioural and environmental factors specific to community-dwelling patients; the interview format also facilitates patient-provider interaction. © 2013 John Wiley & Sons Ltd.
Inter-rater reliability of an observation-based ergonomics assessment checklist for office workers.
Pereira, Michelle Jessica; Straker, Leon Melville; Comans, Tracy Anne; Johnston, Venerina
2016-12-01
To establish the inter-rater reliability of an observation-based ergonomics assessment checklist for computer workers. A 37-item (38-item if a laptop was part of the workstation) comprehensive observational ergonomics assessment checklist comparable to government guidelines and up to date with empirical evidence was developed. Two trained practitioners assessed full-time office workers performing their usual computer-based work and evaluated the suitability of workstations used. Practitioners assessed each participant consecutively. The order of assessors was randomised, and the second assessor was blinded to the findings of the first. Unadjusted kappa coefficients between the raters were obtained for the overall checklist and subsections that were formed from question-items relevant to specific workstation equipment. Twenty-seven office workers were recruited. The inter-rater reliability between two trained practitioners achieved moderate to good reliability for all except one checklist component. This checklist has mostly moderate to good reliability between two trained practitioners. Practitioner Summary: This reliable ergonomics assessment checklist for computer workers was designed using accessible government guidelines and supplemented with up-to-date evidence. Employers in Queensland (Australia) can fulfil legislative requirements by using this reliable checklist to identify and subsequently address potential risk factors for work-related injury to provide a safe working environment.
Reliability and validity of current physical examination techniques of the foot and ankle.
Wrobel, James S; Armstrong, David G
2008-01-01
This literature review was undertaken to evaluate the reliability and validity of the orthopedic, neurologic, and vascular examination of the foot and ankle. We searched PubMed-the US National Library of Medicine's database of biomedical citations-and abstracts for relevant publications from 1966 to 2006. We also searched the bibliographies of the retrieved articles. We identified 35 articles to review. For discussion purposes, we used reliability interpretation guidelines proposed by others. For the kappa statistic that calculates reliability for dichotomous (eg, yes or no) measures, reliability was defined as moderate (0.4-0.6), substantial (0.6-0.8), and outstanding (> 0.8). For the intraclass correlation coefficient that calculates reliability for continuous (eg, degrees of motion) measures, reliability was defined as good (> 0.75), moderate (0.5-0.75), and poor (< 0.5). Intraclass correlations, based on the various examinations performed, varied widely. The range was from 0.08 to 0.98, depending on the examination performed. Concurrent and predictive validity ranged from poor to good. Although hundreds of articles exist describing various methods of lower-extremity assessment, few rigorously assess the measurement properties. This information can be used both by the discerning clinician in the art of clinical examination and by the scientist in the measurement properties of reproducibility and validity.
Reliability of Use, Abuse, and Dependence of Four Types of Inhalants in Adolescents and Young Adults
Ridenour, Ty A.; Bray, Bethany C.; Cottler, Linda B.
2007-01-01
Inhalants, as a class of drugs, consists of heterogeneous substances that include some of the most dangerous drugs on a per use basis. Research on inhalant abuse has lagged behind other drugs partly because of the need for a diagnostic instrument of different types of inhalants. This study was conducted to obtain reliability estimates for the new Substance Abuse Module DSM-IV inhalants diagnoses for four types of inhalants: aerosols, gases, nitrites, and solvents as well as different diagnostic configurations of inhalant use. Participants were 162 community sample adolescents or young adults (mean age = 20.3 years, SD = 2.4). Two-thirds of the sample was male and 83.3% was Caucasian. Kappas and intraclass correlation coefficients were computed to estimate test-retest reliabilities. Results suggested (a) abuse was more common than dependence (34.6% vs. 12.3%), (b) reliabilities of abuse criteria and diagnosis were good to excellent across subtypes, and (c) reliabilities of dependence criteria and diagnoses were poor to good across subtypes. Alternative configurations of DSM-IV criteria that were consistent with previous research on adolescents provided excellent reliabilities across subtypes of inhalants. Moreover, 11.1% of participants experienced inhalants withdrawal. PMID:17576041
Akram, A J; Ireland, A J; Postlethwaite, K C; Sandy, J R; Jerreat, A S
2013-11-01
This article describes the process of validity and reliability testing of a condition-specific quality-of-life measure for patients with hypodontia presenting for orthodontic treatment. The development of the instrument is described in a previous article. Royal Devon and Exeter NHS Foundation Trust & Musgrove Park Hospital, Taunton. The child perception questionnaire was used as a standard against which to test criterion validity. The Bland and Altman method was used to check agreement between the two questionnaires. Construct validity was tested using principal component analysis on the four sections of the questionnaire. Test-retest reliability was tested using intraclass correlation coefficient and Bland and Altman method. Cronbach's alpha was used to test internal consistency reliability. Overall the questionnaire showed good reliability, criterion and construct validity. This together with previous evidence of good face and content validity suggests that the instrument may prove useful in clinical practice and further research. This study has demonstrated that the newly developed condition-specific quality-of-life questionnaire is both valid and reliable for use in young patients with hypodontia. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.
Pu, Wuli; Fu, Daihua; Wang, Zhanhua; Gan, Xinpeng; Lu, Xili; Yang, Li
2018-01-01
Abstract Combining self‐healing functions with damage diagnosing, which can achieve timely healing autonomously, is expected to improve the reliability and reduce life cycle cost of materials. Here, a flexible conductive composite composed of a dynamically crosslinked polyurethane bearing Diels–Alder bonds (PUDA) and carbon nanotubes (CNTs), which possess both crack diagnosing and self‐healing functions, is reported. The introduced dynamic Diels–Alder bonds endow the materials self‐healing function and the powder‐based preparation route based on the specially designed CNTs‐coated PUDA micropowders leads to the formation of segregated CNTs network, which makes the composite possess excellent mechanical properties and high conductivity. Because of the sufficient electrothermal and photothermal effect of CNTs, the composites can be healed rapidly and repeatedly by electricity or near‐infrared light based on the retro‐Diels–Alder reaction. An obvious color difference in the infrared thermograph resulting from the resistance difference between damaged and undamaged area can be observed when applying the voltage, which can be used for crack diagnosing. Using the same electrical circuit, the crack in the PUDA/CNTs composite can be noninvasively detected first and then be autonomously healed. The composites also exhibit a strain‐sensing function with good sensitivity and high reliability, thus will have potential applications in electronic strain sensors. PMID:29876226
Measuring the health of populations: the veil of ignorance approach.
Pinto-Prades, José-Luis; Abellán-Perpiñán, José-María
2005-01-01
We report the results from two surveys designed to explore whether an application of Harsanyi's principle of choice form behind a veil of ignorance (VEI) can be used in order to measure the health of populations. This approach was tentatively recommended by Murray et al. (Bull. World Health Organ 2000; 78: 981-994; Summary Measures of population health: Concepts, Ethics, Measurement and Applications, WHO, 2002.) as an appropriate way of constructing summary measures of population health (SMPH) for comparative purposes. The operationalization of the VEI approach used in this paper was suggested by Nord (Summary Measures of Population Health: Concepts, Ethics, Measurement and Applications, WHO, 2002.). We test if VEI and person trade-off (PTO) methods generate similar quality-of-life weights. In addition, we compare VEI and PTO weights with individual utilities estimated by means of the conventional standard gamble (SG) and a variation of it we call double gamble. Finally, psychometric properties like feasibility, reliability, and consistency are examined. Our main findings are next: (1) VEI and PTO approaches generate very different weights; (2) it seems that differences between PTO and VEI are not due to the 'rule of rescue'; (3) the VEI resembled more a DG than a classical SG; (4) PTO, VEI, and DG exhibited good feasibility, reliability and consistency. Copyright 2004 John Wiley & Sons, Ltd.
Markowitz, Leslie A; Reyes, Charina; Embacher, Rebecca A; Speer, Leslie L; Roizen, Nancy; Frazier, Thomas W
2016-10-01
This study investigated the psychometric properties of the Child and Family Quality of Life scale, a measure of psychosocial quality of life in those with autism and related developmental disorders. Parents of 212 children suspected of autism spectrum disorder completed the Child and Family Quality of Life prior to a diagnostic evaluation. Results indicated that the Child and Family Quality of Life measured six unique quality-of-life constructs (child, family/caregiver, financial, external support, partner relationship, and coping), had good reliability across score ranges and exhibited expected patterns of convergent validity. Caregivers of autism spectrum disorder-affected children reported reduced family quality of life prior to the time of diagnosis relative to caregivers of children with other developmental disabilities. The Child and Family Quality of Life is a brief, reliable measure for assessing psychosocial quality of life in families affected by developmental disability. This study is the first to demonstrate impairments in family quality of life early in the developmental course of autism spectrum disorder, prior to formal diagnosis. In addition to traditional child-focused intervention strategies, families with autism spectrum disorder-affected children require early, broad intervention strategies that positively impact the whole family. © The Author(s) 2015.
Finkbeiner, Kristin M; Wilson, Kyle M; Russell, Paul N; Helton, William S
2015-04-01
Performance on the sustained attention to response task (SART) is often characterized by a speed-accuracy trade-off, and SART performance may be influenced by strategic factors (Head and Helton Conscious Cogn 22: 913-919, 2013). Previous research indicates a significant difference between reliable and unreliable warning cues on response times and errors (commission and omission), suggesting that SART tasks are influenced by strategic factors (Helton et al. Conscious Cogn 20: 1732-1737, 2011; Exp Brain Res 209: 401-407, 2011). With regards to warning stimuli, we chose to use cute images (exhibiting infantile features) during a SART, as previous literature indicates cute images cause participants to engage attention. If viewing cute things makes the viewer exert more attention than normal, then exposure to cute stimuli during the SART should improve performance if SART performance is a measure of perceptual coupling. Reliable warning cues were shown to reduce both response time and errors of commission, and increase errors of omission, relative to unreliable warning cues. Cuteness of the warning stimuli, however, had no significant effect on SART performance. These results suggest the importance of strategic factors in SART performance, not increased attention, and add to the growing literature which suggests the SART is not a good measure of sustained attention, vigilance or perceptual coupling.
Vermersch, Patrick; Hobart, Jeremy; Dive-Pouletty, Catherine; Bozzi, Sylvie; Hass, Steven; Coyle, Patricia K
2017-04-01
The Treatment Satisfaction Questionnaire for Medication (TSQM) was designed to assess patient treatment satisfaction in chronic diseases. Its performance has not been examined in multiple sclerosis (MS). The 14 items of the TSQM cover four domains: Effectiveness, Side Effects, Convenience, and Global Satisfaction. To evaluate performance of the TSQM in patients with relapsing MS, using data collected from the TENERE study (NCT00883337), in which 324 patients received oral teriflunomide or subcutaneous interferon beta-1a for ⩾48 weeks. Five measurement properties were examined using traditional psychometric methods: data completeness, scale-to-sample targeting, scaling assumptions, reliability (including test-retest), and construct validity (internal: item-level scaling success, confirmatory factor analysis, and exploratory factor analysis; external: convergence, discrimination, and group differences). There were few (<2%) missing item data; domain scores could be computed for all patients. Score distributions were skewed toward higher satisfaction; two domains had marked ceiling effects. Scaling assumptions were supported. Internal consistency reliability was high (Cronbach's α > 0.90). Internal validity tests supported item groupings. Correlations supported convergent and discriminant construct validity; hypothesis testing supported group differences validity. This investigation found the TSQM to be a useful tool, exhibiting good psychometric measurement properties in patients with relapsing MS in the TENERE study.
Striking against bioterrorism with advanced proteomics and reference methods.
Armengaud, Jean
2017-01-01
The intentional use by terrorists of biological toxins as weapons has been of great concern for many years. Among the numerous toxins produced by plants, animals, algae, fungi, and bacteria, ricin is one of the most scrutinized by the media because it has already been used in biocrimes and acts of bioterrorism. Improving the analytical toolbox of national authorities to monitor these potential bioweapons all at once is of the utmost interest. MS/MS allows their absolute quantitation and exhibits advantageous sensitivity, discriminative power, multiplexing possibilities, and speed. In this issue of Proteomics, Gilquin et al. (Proteomics 2017, 17, 1600357) present a robust multiplex assay to quantify a set of eight toxins in the presence of a complex food matrix. This MS/MS reference method is based on scheduled SRM and high-quality standards consisting of isotopically labeled versions of these toxins. Their results demonstrate robust reliability based on rather loose scheduling of SRM transitions and good sensitivity for the eight toxins, lower than their oral median lethal doses. In the face of an increased threat from terrorism, relevant reference assays based on advanced proteomics and high-quality companion toxin standards are reliable and firm answers. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kaufman, Denise R; Puckett, Mallory J; Smith, Mitchell J; Wilson, Kyle S; Cheema, Rebecca; Landers, Merrill R
2014-08-01
The purpose of this study was to establish reliability and responsiveness of the dynamic visual acuity test (DVAT) at head speeds of 150-200 degrees per second (deg/s) and the gaze stabilization test (GST) in high school and college football players. Reliability design. Fifty high school and college football athletes completed the DVAT and GST in both the yaw (horizontal) and pitch (vertical) planes twice within two weeks. Test-retest reliability for the DVAT was good in yaw, Intraclass Correlation Coefficient (ICC) = 0.770, and moderate/good in pitch, ICC = 0.725. Minimal detectable change (MDC) was 0.16 logMAR for yaw and 0.21 logMAR for pitch. GST reliability was moderate in yaw, ICC = 0.634, and poor in pitch, ICC = 0.411. MDCs were 73.4 deg/s (yaw) and 81.2 deg/s (pitch). The DVAT is reliable at high head speeds in high school and college football athletes in both yaw and pitch. GST head speeds were higher than previously reported in the literature, but reliability of this tool for this population was poor to moderate. From a clinical perspective, DVAT may be reliably used in the assessment of high school and college football athletes; however, GST requires further evaluation. Copyright © 2013 Elsevier Ltd. All rights reserved.
Lester, David; Abdel-Khalek, Ahmed
2002-08-01
In a sample of 460 Kuwaiti undergraduates and 273 American students, the Taoist-Orientation scale had different factor patterns in an item-analysis but had good internal consistency reliability for both samples.
Katzan, Irene L; Lapin, Brittany
2018-01-01
The International Consortium for Health Outcomes Measurement recently included the 10-item PROMIS GH (Patient-Reported Outcomes Measurement Information System Global Health) scale as part of their recommended Standard Set of Stroke Outcome Measures. Before collection of PROMIS GH is broadly implemented, it is necessary to assess its performance in the stroke population. The objective of this study was to evaluate the psychometric properties of PROMIS GH in patients with ischemic stroke and intracerebral hemorrhage. PROMIS GH and 6 PROMIS domain scales measuring same/similar constructs were electronically collected on 1102 patients with ischemic and hemorrhagic strokes at various stages of recovery from their stroke who were seen in a cerebrovascular clinic from October 12, 2015, through June 2, 2017. Confirmatory factor analysis was performed to evaluate the adequacy of 2-factor structure of component scores. Test-retest reliability and convergent validity of PROMIS GH items and component scores were assessed. Discriminant validity and responsiveness were compared between PROMIS GH and PROMIS domain scales measuring the same or related constructs. Analyses were repeated stratified by stroke subtype and modified Rankin Scale score <2 versus ≥2. There was moderate internal reliability (ordinal α, 0.82-0.88) and marginal model fit for the 2-factor solution for component scores (root mean square error of approximation, 0.11). Convergent validity was good with significant correlations between all PROMIS GH items and PROMIS domain scales ( P <0.001 for all). There was excellent discrimination for all PROMIS GH items and component scores across modified Rankin Scale levels. Good responsiveness (effect size, >0.5) was demonstrated for 8 of the 10 PROMIS GH items. Reliability and validity remained consistent across stroke subtype and disability level (modified Rankin Scale, <2 versus ≥2). PROMIS GH exhibits acceptable performance in patients with stroke. Our findings support International Consortium for Health Outcomes Measurement recommendation to use PROMIS GH as part of the standard set of outcome measures in stroke. © 2017 American Heart Association, Inc.
Annear, Michael J; Toye, Chris; Elliott, Kate-Ellen J; McInerney, Frances; Eccleston, Claire; Robinson, Andrew
2017-07-31
Dementia is a life-limiting condition that is increasing in global prevalence in line with population ageing. In this context, it is necessary to accurately measure dementia knowledge across a spectrum of health professional and lay populations with the aim of informing targeted educational interventions and improving literacy, care, and support. Building on prior exploratory analysis, which informed the development of the preliminarily valid and reliable version of the Dementia Knowledge Assessment Scale (DKAS), a Confirmatory Factor Analysis (CFA) was performed to affirm construct validity and proposed subscales to further increase the measure's utility for academics and educators. A large, de novo sample of 3649 volunteer respondents to a dementia-related online course was recruited to evaluate the performance of the DKAS and its proposed subscales. Respondents represented diverse cohorts, including health professionals, students, and members of the general public. Analyses included CFA (using structural equation modelling), measures of internal consistency (α), and non-parametric tests of subscale correlation (Spearman Correlation) and score differences between cohorts (Kruskal-Wallis one-way analysis of variance). Findings of the CFA supported a 25-item, four-factor model for the DKAS with two items removed due to poor performance and one item moved between factors. The resultant model exhibited good reliability (α = .85; ω h = .87; overall scale), with acceptable subscale internal consistency (α ≥ .65; subscales). Subscales showed acceptable correlation without any indication of redundancy. Finally, total and DKAS subscale scores showed good discrimination between cohorts of respondents who would be anticipated to hold different levels of knowledge on the basis of education or experience related to dementia. The DKAS has been confirmed as a reliable and valid measure of dementia knowledge for diverse populations that is capable of elucidating knowledge characteristics across four coherent domains: 1) Causes and Characteristics, 2) Communication and Behaviour, 3) Care Considerations, and 4) Risks and Health Promotion. Importantly, the four confirmed subscales clearly distinguish between groups who might be expected to hold differing levels of knowledge about dementia, allowing for a fine-grained level of detail to be established when evaluating baseline understanding or knowledge change associated with educational intervention.
The Reliability of Anthropometric Measurements Used Preoperatively in Aesthetic Breast Surgery.
Isaac, Kathryn V; Murphy, Blake D; Beber, Brett; Brown, Mitchell
2016-04-01
Patient outcomes in aesthetic breast surgery are highly dependent on breast measurements used in preoperative planning. The purpose of this study is to determine the reliability of anthropometric breast measurements. Four raters measured 28 women using 7 measurements: sternal notch to nipple distance (Sn-N), nipple to midline (N-M), nipple to inframammary-fold distance under maximal stretch (N-IMF), breast base width (BW), soft tissue pinch thickness of the upper pole (STPT:UP), STPT at the inframammary fold (STPT:IMF), and anterior pull skin stretch (APSS). Reliability was assessed using intra-class correlation coefficients (ICCs). Inter-rater reliability was excellent for Sn-N, N-M, and BW (ICC = 0.94, 0.90, and 0.76, respectively) and was good for N-IMF (ICC = 0.70). The STPT:UP, STPT:IMF, and APSS measurements were not reliable between raters (ICC < 0.2). Intra-rater reliability was excellent for Sn-N, N-M, and BW for all raters (all ICC > 0.75). The N-IMF intra-rater reliability was excellent in senior raters (ICC > 0.75) and good in junior raters (ICC > 0.6). The STPT:UP, STPT:IMF, and APSS measurements showed fair or poor reliability for most raters (ICC < 0.6). The Sn-N, N-M, and BW measurements are very reliable. Dynamic measurements including APSS, STPT:UP, and STUP:IMF are unreliable. N-IMF is the only reliable dynamic measurement, and its reliability improves with increasing clinical experience. The variable reliability of preoperative measurements must be considered in the planning of aesthetic breast surgery. 4 Diagnostic. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Kaplan, J.; Howitt, R. E.; Kroll, S.
2016-12-01
Public financing of public projects is becoming more difficult with growing political and financial pressure to reduce the size and scope of government action. Private provision is possible but is often doomed by under-provision. If however, market-like mechanisms could be incorporated into the solicitation of funds to finance the provision of the good, because, for example, the good is supplied stochastically and is divisible, then we would expect fewer incentives to free ride and greater efficiency in providing the public good. In a controlled computer-based economic experiment, we evaluate two market-like conditions (reliability pricing allocation and self-sizing of the good) that are designed to reduce under-provision. The results suggest that financing an infrastructure project when the delivery is allocated based on reliability pricing rather than historical allocation results in significantly greater price formation efficiency and less free riding whether the project is of a fixed size determined by external policy makers or determined endogenously by the sum of private contributions. When reliability pricing and self-sizing (endogenous) mechanism are used in combination free-riding is reduced the greatest among the tested treatments. Furthermore, and as expected, self-sizing when combined with historical allocations results in the worst level of free-riding. This setting for this treatment creates an incentive to undervalue willingness to pay since very low contributions still return positive earnings as long as enough contributions are raised for a single unit. If everyone perceives everyone else is undervaluing their contribution the incentive grows stronger and we see the greatest degree of free riding among the treatments. Lastly, the results from the analysis suggested that the rebate rule may have encouraged those with willingness to pay values less than the cost of the project to feel confident when contributing more than their willingness to pay and to do so when they faced the endogenously-sized, reliability pricing solicitation since a rebate would likely return them positive earnings. In subsequent research we would like to explore the role of the rebate rule in the effectiveness of reliability pricing and self-sizing in increasing price-formation efficiency and reduce free riding.
Reliability and validity of the Microsoft Kinect for assessment of manual wheelchair propulsion.
Milgrom, Rachel; Foreman, Matthew; Standeven, John; Engsberg, Jack R; Morgan, Kerri A
2016-01-01
Concurrent validity and test-retest reliability of the Microsoft Kinect in quantification of manual wheelchair propulsion were examined. Data were collected from five manual wheelchair users on a roller system. Three Kinect sensors were used to assess test-retest reliability with a still pose. Three systems were used to assess concurrent validity of the Kinect to measure propulsion kinematics (joint angles, push loop characteristics): Kinect, Motion Analysis, and Dartfish ProSuite (Dartfish joint angles were limited to shoulder and elbow flexion). Intraclass correlation coefficients revealed good reliability (0.87-0.99) between five of the six joint angles (neck flexion, shoulder flexion, shoulder abduction, elbow flexion, wrist flexion). ICCs suggested good concurrent validity for elbow flexion between the Kinect and Dartfish and between the Kinect and Motion Analysis. Good concurrent validity was revealed for maximum height, hand-axle relationship, and maximum area (0.92-0.95) between the Kinect and Dartfish and maximum height and hand-axle relationship (0.89-0.96) between the Kinect and Motion Analysis. Analysis of variance revealed significant differences (p < 0.05) in maximum length between Dartfish (mean 58.76 cm) and the Kinect (40.16 cm). Results pose promising research and clinical implications for propulsion assessment and overuse injury prevention with the application of current findings to future technology.
Lee, Soo Cheng; Moy, Foong Ming; Hairi, Noran Naqiah
2017-01-01
The multidimensional scale of perceived social support (MSPSS) was developed to measure perceived social support. It has been translated and culturally adapted among natives literate in the Malay language. However, its psychometric properties for teachers who are majority females and married have not been assessed. This was a cross-sectional study conducted among the public secondary school teachers in the central region of Peninsular Malaysia from May to July 2013. A total of 150 and 203 teachers were recruited to perform exploratory factor analysis and confirmatory factor analysis (CFA), respectively. Reliability testing was evaluated on 141 teachers via internal consistency and two-week interval test-retest. The 12-item three-factor structure of MSPSS-M was revised to 8-item two-factor structure. The revised MSPSS-M demonstrated excellent fit in CFA with adequate divergent and convergent validity and good factor loadings (0.80-0.90). The revised MSPSS-M also displayed good internal consistency with Cronbach's alpha of 0.91, 0.93 and 0.92 and good test-retest reliability with intraclass correlation of 0.89, 0.88 and 0.88 in the total scale, family and friends factors, respectively. The revised 8-item MSPSS-M is a reliable and valid tool for assessment of perceived social support among teachers.
Harris, Meredith; Gladman, Beverley; Hennessy, Nicole; Lloyd, Chris; Mowry, Bryan; Waghorn, Geoffrey
2011-06-01
The aim was to investigate the reliability and validity of the Socially Valued Role Classification Scale (SRCS), a domain-specific measure of role functioning designed for use with community residents with psychiatric disabilities. Test-retest reliability, concurrent validity, face validity, consumer and clinician acceptability and utility were examined. Sixty community residents with schizophrenia or schizoaffective disorder participated in this study where the SRCS was administered by telephone. Test-retest reliability showed good or very good agreement for subscale scores (intraclass correlations (ICCs): 0.78-0.89) and for items capturing amount of participation in domain-specific activities (ICC: 0.67-1.00). Greater variation was observed for items capturing assistance required with activities (κ: 0.40-0.75), and standard of activities performed (κ: 0.43-1.00). Concurrent validity was supported by moderate to very good associations in the directions expected. Face validity, user acceptability and utility in telephone interviews were adequate. These findings add to previous psychometric evidence and support the continued development of the SRCS for use in community mental health settings. The SRCS has promising utility for occupational therapists involved in psychiatric rehabilitation outcome measurement. © 2011 Queensland Health - QCMHR. Australian Occupational Therapy Journal © 2011 Australian Association of Occupational Therapists.
Wennberg, Richard; Cheyne, Douglas
2014-05-01
To assess the reliability of MEG source imaging (MSI) of anterior temporal spikes through detailed analysis of the localization and orientation of source solutions obtained for a large number of spikes that were separately confirmed by intracranial EEG to be focally generated within a single, well-characterized spike focus. MSI was performed on 64 identical right anterior temporal spikes from an anterolateral temporal neocortical spike focus. The effects of different volume conductors (sphere and realistic head model), removal of noise with low frequency filters (LFFs) and averaging multiple spikes were assessed in terms of the reliability of the source solutions. MSI of single spikes resulted in scattered dipole source solutions that showed reasonable reliability for localization at the lobar level, but only for solutions with a goodness-of-fit exceeding 80% using a LFF of 3 Hz. Reliability at a finer level of intralobar localization was limited. Spike averaging significantly improved the reliability of source solutions and averaging 8 or more spikes reduced dependency on goodness-of-fit and data filtering. MSI performed on topographically identical individual spikes from an intracranially defined classical anterior temporal lobe spike focus was limited by low reliability (i.e., scattered source solutions) in terms of fine, sublobar localization within the ipsilateral temporal lobe. Spike averaging significantly improved reliability. MSI performed on individual anterior temporal spikes is limited by low reliability. Reduction of background noise through spike averaging significantly improves the reliability of MSI solutions. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Measuring Maladaptive Cognitions in Complicated Grief: Introducing the Typical Beliefs Questionnaire
Skritskaya, Natalia A.; Mauro, Christine; Olonoff, Matthew; Qiu, Xin; Duncan, Sarah; Wang, Yuanjia; Duan, Naihua; Lebowitz, Barry; Reynolds, Charles F.; Simon, Naomi M.; Zisook, Sidney; Shear, M. Katherine
2016-01-01
Objectives Maladaptive cognitions related to loss are thought to contribute to development of complicated grief and are crucial to address in treatment, but tools available to assess them are limited. This paper introduces the Typical Beliefs Questionnaire (TBQ), a 25-item self-report instrument to assess cognitions that interfere with adaptation to loss. Design Study participants completed an assessment battery during their initial evaluation and again after completing treatment at 20 weeks. Test-retest reliability was assessed on a subsample of the participants who did not show change in complicated grief severity after the first four weeks of treatment. To examine latent structure of the TBQ, an exploratory factor analysis (EFA) was performed. Setting Academic medical centers in Boston, New York, Pittsburgh and San Diego from 2010–2014. Participants 394 bereaved adults who met criteria for complicated grief. Measurements The TBQ along with assessments of complicated grief symptoms and related avoidance, depression symptoms, functional impairment, and perceived social support. Results The TBQ exhibited good internal consistency (α= .82) and test-retest reliability (n=105; ICC= .74). EFA indicated a five-factor structure: “Protesting the Death,” “Negative Thoughts About the World,” “Needing the Person,” “Less Grief is Wrong” and “Grieving Too Much.” The total score and all factors showed sensitivity to change with treatment. Conclusions This new tool allows a clinician to quickly and reliably ascertain presence of specific maladaptive cognitions related to complicated grief, and subsequently, to use the information to aid a diagnostic assessment, to structure the treatment, and to measure treatment outcomes. PMID:27793576
Shuval, Kerem; Kohl, Harold W; Bernstein, Ira; Cheng, Dunlei; Pettee Gabriel, Kelley; Barlow, Carolyn E; Yinghui, Liu; DiPietro, Loretta
2014-02-01
The emerging evidence of the effects of sedentary time on health outcomes suggests a need to better measure this exposure. Healthcare settings, however, are not equipped with a tool that can quickly assess the sedentary habits of their patient population. The purpose of this study was to validate a tool for rapidly quantifying and tracking the sedentary time and low levels of daily lifestyle physical activity among primary care patients. The study examined the test-retest reliability and validity of the rapid assessment disuse index (RADI) among adult patients from a large primary care clinic. Patients completed RADI (comprised of 3 items: sitting, moving and stair climbing) twice, followed by accelerometer monitoring. Test-retest reliability was computed, and the correlation between survey responses and accelerometry was determined. A receiver operating characteristic curve was constructed and the area under the curve (AUC) was calculated. RADI was temporally stable (intraclass correlation coefficients 0.79), and a higher score was significantly correlated with greater sedentary time (ρ=0.40; p<0.01), fewer sedentary to active transitions (ρ=-0.42; p<0.01), and less light-intensity physical activity (ρ=-0.40; p<0.01). The ability of RADI to detect patients with high levels of sedentary time was fair (AUC=0.72). This brief assessment tool, designed to quickly identify patients with high levels of sitting and low daily physical activity, exhibits good reliability and moderate validity. RADI can assist in providing recommendations at the point of care pertaining to modifying sedentary behaviour.
Wood, David L; Sawicki, Gregory S; Miller, M David; Smotherman, Carmen; Lukens-Bull, Katryne; Livingood, William C; Ferris, Maria; Kraemer, Dale F
2014-01-01
National consensus statements recommend that providers regularly assess the transition readiness skills of adolescent and young adults (AYA). In 2010 we developed a 29-item version of Transition Readiness Assessment Questionnaire (TRAQ). We reevaluated item performance and factor structure, and reassessed the TRAQ's reliability and validity. We surveyed youth from 3 academic clinics in Jacksonville, Florida; Chapel Hill, North Carolina; and Boston, Massachusetts. Participants were AYA with special health care needs aged 14 to 21 years. From a convenience sample of 306 patients, we conducted item reduction strategies and exploratory factor analysis (EFA). On a second convenience sample of 221 patients, we conducted confirmatory factor analysis (CFA). Internal reliability was assessed by Cronbach's alpha and criterion validity. Analyses were conducted by the Wilcoxon rank sum test and mixed linear models. The item reduction and EFA resulted in a 20-item scale with 5 identified subscales. The CFA conducted on a second sample provided a good fit to the data. The overall scale has high reliability overall (Cronbach's alpha = .94) and good reliability for 4 of the 5 subscales (Cronbach's alpha ranging from .90 to .77 in the pooled sample). Each of the 5 subscale scores were significantly higher for adolescents aged 18 years and older versus those younger than 18 (P < .0001) in both univariate and multivariate analyses. The 20-item, 5-factor structure for the TRAQ is supported by EFA and CFA on independent samples and has good internal reliability and criterion validity. Additional work is needed to expand or revise the TRAQ subscales and test their predictive validity. Copyright © 2014 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.
Giezen, Hilde; Stevens, Martin; van den Akker-Scheek, Inge; Reininga, Inge H F
2017-01-01
The Copenhagen Hip And Groin Outcome Score (HAGOS) was developed to assess disease-specific consequences in young to middle-aged, physically active hip and/or groin patients. The study aimed to determine validity and reliability of the Dutch version of the HAGOS (HAGOS-NL) for middle-aged patients with hip complaints. To assess validity, 117 participants completed five questionnaires: HAGOS-NL, international Hip Outcome Tool (iHOT-12NL), Hip disability and Osteoarthritis Outcome Score (HOOS), RAND-36 Health Survey and Tegner activity scale. Structural validity was determined by conducting confirmatory factor analysis. Construct validity was analyzed by formulating predefined hypotheses regarding relationships between the HAGOS-NL and subscales of the iHOT-12NL, HOOS, RAND-36 and Tegner activity scale. The HAGOS-NL was filled out again by 67 patients to explore test-retest reliability. Reliability was assessed in terms of Cronbach's alpha, Intraclass Correlation Coefficient (ICC), Standard Error of Measurement (SEM) and Minimal Detectable Change (MDC). The Bland and Altman method was used to explore absolute agreement. Factor analysis confirmed that the HAGOS-NL consists of six subscales. All hypotheses were confirmed, indicating good construct validity. Internal consistency was good, with Cronbach's alpha values ranging from 0.89 to 0.98. Test-retest reliability was considered good, with ICC values of 0.80 and higher. The SEM ranged from 6.6 to 12.3, and MDC at individual level from 18.3 to 34.1 and at group level from 2.3 to 4.4. Bland and Altman analyses showed no bias. The HAGOS-NL is a reliable and valid instrument for measuring pain, physical functioning and quality of life in middle-aged patients with hip complaints.
Cross-cultural Adaption and Validation of the Danish Voice Handicap Index.
Sorensen, Jesper Roed; Printz, Trine; Mehlum, Camilla Slot; Heidemann, Christian Hamilton; Groentved, Aagot Moeller; Godballe, Christian
2018-02-02
We aimed to assess psychometric properties, including internal consistency, reliability, and clinical validity of the Danish version of the Voice Handicap Index (VHI). A cross-sectional survey study was carried out. For validation, the existing nonvalidated Danish version of the VHI was used. Data from 208 patients with voice disorders of different etiology (neurogenic, functional, and structural) and a control group of 85 vocally healthy individuals were included. A test-retest reliability analysis of 42 patients and 45 control persons was performed. The internal consistency, test-retest reliability, and clinical validity of the questionnaire were assessed. Internal consistency was high with a Cronbach α >0.90 for both the patient and control group. Test-retest reliability measured as intraclass correlation coefficient was good with 0.93 (95% confidence interval [95% confidence interval]: 0.87-0.96) for patients and 0.78 (95% confidence interval: 0.63-0.87) for the control group which indicates sufficient reliability of the questionnaire. The Danish VHI has good clinical validity as it has a strong correlation between patient's perception of the severity of their voice disorder and the VHI score from the Spearman correlation of 0.69. The existing Danish version of the VHI has been thoroughly validated and found to be in line with the original VHI from Jacobsen et al. It showed good internal consistency, test-retest reliability, and clinical validity. It is suitable for use in daily practice and in research projects as it is able to assess patients' perception of their voice disorder severity. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Reliability of Two Smartphone Applications for Radiographic Measurements of Hallux Valgus Angles.
Mattos E Dinato, Mauro Cesar; Freitas, Marcio de Faria; Milano, Cristiano; Valloto, Elcio; Ninomiya, André Felipe; Pagnano, Rodrigo Gonçalves
The objective of the present study was to assess the reliability of 2 smartphone applications compared with the traditional goniometer technique for measurement of radiographic angles in hallux valgus and the time required for analysis with the different methods. The radiographs of 31 patients (52 feet) with a diagnosis of hallux valgus were analyzed. Four observers, 2 with >10 years' experience in foot and ankle surgery and 2 in-training surgeons, measured the hallux valgus angle and intermetatarsal angle using a manual goniometer technique and 2 smartphone applications (Hallux Angles and iPinPoint). The interobserver and intermethod reliability were estimated using intraclass correlation coefficients (ICCs), and the time required for measurement of the angles among the 3 methods was compared using the Friedman test. A very good or good interobserver reliability was found among the 4 observers measuring the hallux valgus angle and intermetatarsal angle using the goniometer (ICC 0.913 and 0.821, respectively) and iPinPoint (ICC 0.866 and 0.638, respectively). Using the Hallux Angles application, a very good interobserver reliability was found for measurements of the hallux valgus angle (ICC 0.962) and intermetatarsal angle (ICC 0.935) only among the more experienced observers. The time required for the measurements was significantly shorter for the measurements using both smartphone applications compared with the goniometer method. One smartphone application (iPinPoint) was reliable for measurements of the hallux valgus angles by either experienced or nonexperienced observers. The use of these tools might save time in the evaluation of radiographic angles in the hallux valgus. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Sarig Bahat, Hilla; Sprecher, Elliot; Sela, Itamar; Treleaven, Julia
2016-07-01
The use of virtual reality (VR) for assessment and intervention of neck pain has previously been used and shown reliable for cervical range of motion measures. Neck VR enables analysis of task-oriented neck movement by stimulating responsive movements to external stimuli. Therefore, the purpose of this study was to establish inter-tester reliability of neck kinematic measures so that it can be used as a reliable assessment and treatment tool between clinicians. This reliability study included 46 asymptomatic participants, who were assessed using the neck VR system which displayed an interactive VR scenario via a head-mounted device, controlled by neck movements. The objective of the interactive assessment was to hit 16 targets, randomly appearing in four directions, as fast as possible. Each participant was tested twice by two different testers. Good reliability was found of neck motion kinematic measures in flexion, extension, and rotation (0.64-0.93 inter-class correlation). High reliability was shown for peak velocity globally (0.93), in left rotation (0.9), right rotation and extension (0.88), and flexion (0.86). Mean velocity had a good global reliability (0.84), except for left rotation directed movement with moderate reliability (0.68). Minimal detectable change for peak velocity ranged from 41 to 53 °/s, while mean velocity ranged from 20 to 25 °/s. The results suggest high reliability for peak and mean velocity as measured by the interactive Neck VR assessment of neck motion kinematics. VR appears to provide a reliable and more ecologically valid method of cervical motion evaluation than previous conventional methodologies.
Rathi, Sangeeta; Taylor, Nicholas F; Gee, Jamie; Green, Rodney A
2016-12-01
Ultrasonography is an economical and non-invasive method for measuring real-time joint movements. Although physiotherapists are increasingly using ultrasound imaging for rotator cuff disorders, there is a lack of evidence on their reliability in using ultrasonography to measure glenohumeral translation. The aim of this study was to evaluate the reliability of a physiotherapist in measuring anterior and posterior glenohumeral joint translation with ultrasound. Study design: within day reliability. Anterior and posterior glenohumeral translations were measured at rest, in response to passive accessory motion testing force, and with isometric internal and external rotation in 12 young healthy adults. All the measurements were made in real time by a physiotherapist and an experienced sonographer in two positions (neutral and abducted) and in two views (anterior and posterior). Intra-rater and inter-rater reliability were expressed using intraclass correlation coefficients (ICC) and measurement error (mm). Intra-rater reliability was good for both raters (ICC P : 0.86-0.98; ICC S : 0.85-0.96). The inter-rater reliability between the physiotherapist and sonographer was moderate to good for posterior measurements (ICC 0.50-0.75) and poor to moderate for anterior measurements (ICC 0.31-0.53). For both intra-rater and inter-rater measurements, posterior translation was more reliable than the anterior translation with smaller measurement errors (posterior: 0.1-0.2 mm, anterior: 0.2-0.3 mm). A physiotherapist with minimal training was reliable in measuring glenohumeral joint translations. The ultrasound method was reliable for repeated measurement of both anterior and posterior glenohumeral translations with posterior measurements being more reliable than anterior. This method is recommended for future research to investigate the stabilising role of rotator cuff muscles. Copyright © 2016 Elsevier Ltd. All rights reserved.
Gärtner, Fania R; de Miranda, Esteriek; Rijnders, Marlies E; Freeman, Liv M; Middeldorp, Johanna M; Bloemenkamp, Kitty W M; Stiggelbout, Anne M; van den Akker-van Marle, M Elske
2015-10-01
To validate the Labor and Delivery Index (LADY-X), a new delivery-specific utility measure. In a test-retest design, women were surveyed online, 6 to 8 weeks postpartum and again 1 to 2 weeks later. For reliability testing, we assessed the standard error of measurement (S.E.M.) and the intraclass correlation coefficient (ICC). For construct validity, we tested hypotheses on the association with comparison instruments (Mackey Childbirth Satisfaction Rating Scale and Wijma Delivery Experience Questionnaire), both on domain and total score levels. We assessed known-group differences using eight obstetrical indicators: method and place of birth, induction, transfer, control over pain medication, complications concerning mother and child, and experienced control. The questionnaire was completed by 308 women, 257 (83%) completed the retest. The distribution of LADY-X scores was skewed. The reliability was good, as the ICC exceeded 0.80 and the S.E.M. was 0.76. Requirements for good construct validity were fulfilled: all hypotheses for convergent and divergent validity were confirmed, and six of eight hypotheses for known-group differences were confirmed as all differences were statistically significant (P-values: <0.001-0.023), but for two tests, difference scores did not exceed the S.E.M. The LADY-X demonstrates good reliability and construct validity. Despite its skewed distribution, the LADY-X can discriminate between groups. With the preference weights available, the LADY-X might fulfill the need for a utility measure for cost-effectiveness studies for perinatal care interventions. Copyright © 2015 Elsevier Inc. All rights reserved.
Hernansaiz-Garrido, Helena; Alonso-Tapia, Jesús
2017-01-01
Internalized stigma and disclosure concerns are key elements for the study of mental health in people living with HIV. Since no measures of these constructs were available for Spanish population, this study sought to develop such instruments, to analyze their reliability and validity and to provide a short version. A heterogeneous sample of 458 adults from different Spanish-speaking countries completed the HIV-Internalized Stigma Scale and the HIV-Disclosure Concerns Scale, along with the Hospital Anxiety and Depression Scale, Rosenberg's Self-esteem Scale and other socio-demographic variables. Reliability and correlation analyses, exploratory factor analyses, path analyses with latent variables, and ANOVAs were conducted to test the scales' psychometric properties. The scales showed good reliability in terms of internal consistency and temporal stability, as well as good sensitivity and factorial and criterion validity. The HIV-Internalized Stigma Scale and the HIV-Disclosure Concerns Scale are reliable and valid means to assess these variables in several contexts.
Reliability and validity of a physical activity scale among urban pregnant women in eastern China.
Jiang, Hong; He, Gengsheng; Li, Mu; Fan, Yanyan; Jiang, Hongyi; Bauman, Adrian; Qian, Xu
2015-03-01
This study aimed to determine the reliability and validity of the physical activity scale adapted from a Danish scale for assessing physical activity among urban pregnant women in eastern China. Participants recruited in an urban setting of eastern China were asked to complete the physical activity scale, the activity diary, and to wear a pedometer for the same 4 days, followed by repeating the activity scale for another 4 days within 2 weeks. A total of 109 pregnant women completed data recording. Good reliability of the physical activity scale was observed (intraclass correlation coefficient = .87). There was also a good comparability between the activity scale and the activity diary (Spearman's r = .75 for total energy expenditure). The agreement between the scale and pedometer reading was acceptable (Spearman's r = .45). The adapted physical activity scale is a reliable and reasonably accurate instrument for estimating physical activity among urban pregnant women in eastern China. © 2012 APJPH.
Shi, Peipei; Li, Li; Hua, Li; Qian, Qianqian; Wang, Pengfei; Zhou, Jinyuan; Sun, Gengzhi; Huang, Wei
2017-01-24
Solid-state fiber-based supercapacitors have been considered promising energy storage devices for wearable electronics due to their lightweight and amenability to be woven into textiles. Efforts have been made to fabricate a high performance fiber electrode by depositing pseudocapacitive materials on the outer surface of carbonaceous fiber, for example, crystalline manganese oxide/multiwalled carbon nanotubes (MnO 2 /MWCNTs). However, a key challenge remaining is to achieve high specific capacitance and energy density without compromising the high rate capability and cycling stability. In addition, amorphous MnO 2 is actually preferred due to its disordered structure and has been proven to exhibit superior electrochemical performance over the crystalline one. Herein, by incorporating amorphous MnO 2 onto a well-aligned MWCNT sheet followed by twisting, we design an amorphous MnO 2 @MWCNT fiber, in which amorphous MnO 2 nanoparticles are distributed in MWCNT fiber uniformly. The proposed structure gives the amorphous MnO 2 @MWCNT fiber good mechanical reliability, high electrical conductivity, and fast ion-diffusion. Solid-state supercapacitor based on amorphous MnO 2 @MWCNT fibers exhibits improved energy density, superior rate capability, exceptional cycling stability, and excellent flexibility. This study provides a strategy to design a high performance fiber electrode with microstructure control for wearable energy storage devices.
Lee, Ke-Jing; Chang, Yu-Chi; Lee, Cheng-Jung; Wang, Li-Wen; Wang, Yeong-Her
2017-12-09
A one-transistor and one-resistor (1T1R) architecture with a resistive random access memory (RRAM) cell connected to an organic thin-film transistor (OTFT) device is successfully demonstrated to avoid the cross-talk issues of only one RRAM cell. The OTFT device, which uses barium zirconate nickelate (BZN) as a dielectric layer, exhibits favorable electrical properties, such as a high field-effect mobility of 5 cm²/Vs, low threshold voltage of -1.1 V, and low leakage current of 10 -12 A, for a driver in the 1T1R operation scheme. The 1T1R architecture with a TiO₂-based RRAM cell connected with a BZN OTFT device indicates a low operation current (10 μA) and reliable data retention (over ten years). This favorable performance of the 1T1R device can be attributed to the additional barrier heights introduced by using Ni (II) acetylacetone as a substitute for acetylacetone, and the relatively low leakage current of a BZN dielectric layer. The proposed 1T1R device with low leakage current OTFT and excellent uniform resistance distribution of RRAM exhibits a good potential for use in practical low-power electronic applications.
Faragian, Sarit; Kurs, Rena; Poyurovsky, Michael
2008-03-01
A substantial proportion of adolescent schizophrenia patients also has obsessive-compulsive disorder (OCD). As the reliability of OCD identification in schizophrenia has been challenged, we evaluated insight into OCD symptoms and awareness of schizophrenia, using the Brown Assessment of Beliefs Scale and the Scale to Assess Unawareness of Mental Disorder respectively, in 22 adolescent inpatients who met DSM-IV criteria for both schizophrenia and OCD. Awareness of illness was also assessed in a comparison group of 22 non-OCD adolescent schizophrenia patients. Nineteen (86.3%) schizo-obsessive patients exhibited good or fair insight into OCD, while only 3 patients revealed lack of insight. Roughly 30% of patients in the two schizophrenia groups with and without OCD exhibited unawareness of schizophrenia, indicating that the presence of OCD does not substantially modify global awareness of illness. The effect size of the correlation between insight into OCD and awareness of schizophrenia in the schizo-obsessive group was small and not statistically significant. Our findings support the notion that OCD in adolescent schizophrenia patients represent an identifiable dimension of psychopathology independent of core schizophrenia symptoms. Early identification of this potentially treatable syndrome is imperative for appropriate diagnosis and treatment of this unique subset of schizophrenia patients.
Clint, S A; Eastwood, D M; Chasseaud, M; Calder, P R; Marsh, D R
2010-02-01
Although there is much in the literature regarding pin site infections, there is no accepted, validated method for documenting their state. We present a system for reliably labelling pin sites on any ring fixator construct and an easy-to-remember grading system to document the state of each pin site. Each site is graded in terms of erythema, pain and discharge to give a 3-point scale, named "Good", "Bad" and "Ugly" for ease of recall. This system was tested for intra- and inter-observer reproducibility. 15 patients undergoing elective limb reconstruction were recruited. A total of 218 pin sites were independently scored by 2 examiners. 82 were then re-examined later by the same examiners. 514 pin sites were felt to be "Good", 80 "Bad" and 6 "Ugly". The reproducibility of the system was found to be excellent. We feel our system gives a quick, reliable and reproducible method to monitor individual pin sites and their response to treatment. Crown Copyright 2009. Published by Elsevier Ltd. All rights reserved.
B-52 stability augmentation system reliability
NASA Technical Reports Server (NTRS)
Bowling, T. C.; Key, L. W.
1976-01-01
The B-52 SAS (Stability Augmentation System) was developed and retrofitted to nearly 300 aircraft. It actively controls B-52 structural bending, provides improved yaw and pitch damping through sensors and electronic control channels, and puts complete reliance on hydraulic control power for rudder and elevators. The system has experienced over 300,000 flight hours and has exhibited service reliability comparable to the results of the reliability test program. Development experience points out numerous lessons with potential application in the mechanization and development of advanced technology control systems of high reliability.
de Vries, Merlijn W; Visscher, Corine; Delwel, Suzanne; van der Steen, Jenny T; Pieper, Marjoleine J C; Scherder, Erik J A; Achterberg, Wilco P; Lobbezoo, Frank
2016-01-01
Objectives. The aim of this study was to establish the reliability of the "chewing" subscale of the OPS-NVI, a novel tool designed to estimate presence and severity of orofacial pain in nonverbal patients. Methods. The OPS-NVI consists of 16 items for observed behavior, classified into four categories and a subjective estimate of pain. Two observers used the OPS-NVI for 237 video clips of people with dementia in Dutch nursing homes during their meal to observe their behavior and to estimate the intensity of orofacial pain. Six weeks later, the same observers rated the video clips a second time. Results. Bottom and ceiling effects for some items were found. This resulted in exclusion of these items from the statistical analyses. The categories which included the remaining items (n = 6) showed reliability varying between fair-to-good and excellent (interobserver reliability, ICC: 0.40-0.47; intraobserver reliability, ICC: 0.40-0.92). Conclusions. The "chewing" subscale of the OPS-NVI showed a fair-to-good to excellent interobserver and intraobserver reliability in this dementia population. This study contributes to the validation process of the OPS-NVI as a whole and stresses the need for further assessment of the reliability of the OPS-NVI with subjects that might already show signs of orofacial pain.
Miki, Emi; Yamane, Shingo; Yamaoka, Mai; Fujii, Hiroe; Ueno, Hiroka; Kawahara, Toshie; Tanaka, Keiko; Tamashiro, Hiroaki; Inoue, Eiji; Okamoto, Takatsugu; Kuriyama, Masaru
2016-09-01
The study aim was to investigate the validity and reliability of the Functional Independence Measure and Functional Assessment Measure (FIM + FAM), which is unfamiliar in Japan, by using its Japanese version (FIM + FAM-j) in patients with cerebrovascular accident (CVA). Forty-two CVA patients participated. Criterion validity was examined by correlating the full scale and subscales of FIM + FAM-j with several well-established measurements using Spearman's correlation coefficient. Reliability was evaluated by internal consistency (tested by Cronbach's alpha coefficient) and intra-rater reliability (tested by Kendall's tau correlation coefficient). Good-to-excellent criterion validity was found between the full scale and motor subscales of the FIM + FAM-j and the Barthel Index, National Institutes of Health Stroke Scale, modified Rankin Scale, and lower extremity Brunnstrom Recovery Stage. High internal consistency was observed within the full-scale FIM + FAM-j and the motor and cognitive subscales (Cronbach's alphas were 0.968, 0.954, and 0.948, respectively). Additionally, good intra-rater reliability was observed within the full scale and motor subscales, and excellent reliability for the cognitive subscales (taus were 0.83, 0.80, and 0.98, respectively). This study showed that the FIM + FAM-j demonstrated acceptable levels of validity and reliability when used for CVA as a measure of disability.
Cha, Young Joo; Lee, Jae Jin; Kim, Do Hyun; You, Joshua Sung H
2017-10-23
Core stabilization plays an important role in the regulation of postural stability. To overcome shortcomings associated with pain and severe core instability during conventional core stabilization tests, we recently developed the dynamic neuromuscular stabilization-based heel sliding (DNS-HS) test. The purpose of this study was to establish the criterion validity and test-retest reliability of the novel DNS-HS test. Twenty young adults with core instability completed both the bilateral straight leg lowering test (BSLLT) and DNS-HS test for the criterion validity study and repeated the DNS-HS test for the test-retest reliability study. Criterion validity was determined by comparing hip joint angle data that were obtained from BSLLT and DNS-HS measures. The test-retest reliability was determined by comparing hip joint angle data. Criterion validity was (ICC2,3) = 0.700 (p< 0.05), suggesting a good relationship between the two core stability measures. Test-retest reliability was (ICC3,3) = 0.953 (p< 0.05), indicating excellent consistency between the repeated DNS-HS measurements. Criterion validity data demonstrated a good relationship between the gold standard BSLLT and DNS-HS core stability measures. Test-retest reliability data suggests that DNS-HS core stability was a reliable test for core stability. Clinically, the DNS-HS test is useful to objectively quantify core instability and allow early detection and evaluation.
Sleeper, Mark D; Kenyon, Lisa K; Elliott, James M; Cheng, M Samuel
2016-12-01
Despite the availability of various field-tests for many competitive sports, a reliable and valid test specifically developed for use in men's gymnastics has not yet been developed. The Men's Gymnastics Functional Measurement Tool (MGFMT) was designed to assess sport-specific physical abilities in male competitive gymnasts. The purpose of this study was to develop the MGFMT by establishing a scoring system for individual test items and to initiate the process of establishing test-retest reliability and construct validity. A total of 83 competitive male gymnasts ages 7-18 underwent testing using the MGFMT. Thirty of these subjects underwent re-testing one week later in order to assess test-retest reliability. Construct validity was assessed using a simple regression analysis between total MGFMT scores and the gymnasts' USA-Gymnastics competitive level to calculate the coefficient of determination (r 2 ). Test-retest reliability was analyzed using Model 1 Intraclass correlation coefficients (ICC). Statistical significance was set at the p<0.05 level. The relationship between total MGFMT scores and subjects' current USA-Gymnastics competitive level was found to be good (r 2 = 0.63). Reliability testing of the MGFMT composite test score showed excellent test-retest reliability over a one-week period (ICC = 0.97). Test-retest reliability of the individual component tests ranged from good to excellent (ICC = 0.75-0.97). The results of this study provide initial support for the construct validity and test-retest reliability of the MGFMT. Level 3.
Vázquez Peña, Fernando; Harzheim, Erno; Terrasa, Sergio; Berra, Silvina
2017-02-01
To validate the Brazilian short version of the PCAT for adult patients in Spanish. Analysis of secondary data from studies made to validate the extended version of the PCAT questionnaire. City of Córdoba, Argentina. Primary health care. The sample consisted of 46% of parents, whose children were enrolled in secondary education in three institutes in the city of Cordoba, and the remaining 54% were adult users of the National University of Cordoba Health Insurance. Pearson's correlation coefficient comparing the extended and short versions. Goodness-of-fit indices in confirmatory factor analysis, composite reliability, average variance extracted, and Cronbach's alpha values, in order to assess the construct validity and the reliability of the short version. The values of Pearson's correlation coefficient between this short version and the long version were high .818 (P<.001), implying a very good criterion validity. The indicators of good global adjustment to the confirmatory factor analysis were good. The value of composite reliability was good (.802), but under the variance media extracted: .3306, since 3 variables had weak factorials loads. The Cronbach's alpha was acceptable (.85). The short version of the PCAT-users developed in Brazil showed an acceptable psychometric performance in Spanish as a quick assessment tool, in a comparative study with the extended version. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
Koho, P; Aho, S; Kautiainen, H; Pohjolainen, T; Hurri, H
2014-12-01
To estimate the internal consistency, test-retest reliability and comparability of paper and computer versions of the Finnish version of the Tampa Scale of Kinesiophobia (TSK-FIN) among patients with chronic pain. In addition, patients' personal experiences of completing both versions of the TSK-FIN and preferences between these two methods of data collection were studied. Test-retest reliability study. Paper and computer versions of the TSK-FIN were completed twice on two consecutive days. The sample comprised 94 consecutive patients with chronic musculoskeletal pain participating in a pain management or individual rehabilitation programme. The group rehabilitation design consisted of physical and functional exercises, evaluation of the social situation, psychological assessment of pain-related stress factors, and personal pain management training in order to regain overall function and mitigate the inconvenience of pain and fear-avoidance behaviour. The mean TSK-FIN score was 37.1 [standard deviation (SD) 8.1] for the computer version and 35.3 (SD 7.9) for the paper version. The mean difference between the two versions was 1.9 (95% confidence interval 0.8 to 2.9). Test-retest reliability was 0.89 for the paper version and 0.88 for the computer version. Internal consistency was considered to be good for both versions. The intraclass correlation coefficient for comparability was 0.77 (95% confidence interval 0.66 to 0.85), indicating substantial reliability between the two methods. Both versions of the TSK-FIN demonstrated substantial intertest reliability, good test-retest reliability, good internal consistency and acceptable limits of agreement, suggesting their suitability for clinical use. However, subjects tended to score higher when using the computer version. As such, in an ideal situation, data should be collected in a similar manner throughout the course of rehabilitation or clinical research. Copyright © 2014 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Shrivas, Kamlesh; Wu, Hui-Fen
2007-11-02
A simple and rapid sample cleanup and preconcentration method for the quantitative determination of caffeine in one drop of beverages and foods by gas chromatography/mass spectrometry (GC/MS) has been proposed using drop-to-drop solvent microextraction (DDSME). The best optimum experimental conditions for DDSME were: chloroform as the extraction solvent, 5 min extraction time, 0.5 microL exposure volume of the extraction phase and no salt addition at room temperature. The optimized methodology exhibited good linearity between 0.05 and 5.0 microg/mL with correlation coefficient of 0.980. The relative standard deviation (RSD) and limits of detection (LOD) of the DDSME/GC/MS method were 4.4% and 4.0 ng/mL, respectively. Relative recovery of caffeine in beverages and foods were found to be 96.6-101%, which showing good reliability of this method. This DDSME excludes the major disadvantages of conventional method of caffeine extraction, like large amount of organic solvent and sample consumption and long sample pre-treatment process. So, this approach proves that the DDSME/GC/MS technique can be applied as a simple, fast and feasible diagnosis tool for environmental, food and biological application for extremely small amount of real sample analysis.
Zhang, Shouwei; Gao, Huihui; Li, Jiaxing; Huang, Yongshun; Alsaedi, Ahmed; Hayat, Tasawar; Xu, Xijin; Wang, Xiangke
2017-01-05
Metal silicates have attracted extensive interests due to their unique structure and promising properties in adsorption and catalysis. However, their applications were hampered by the complex and expensive synthesis. In this paper, three-dimensional (3D) hierarchical flower-like metal silicate, including magnesium silicate, zinc silicate, nickel silicate and cobalt silicate, were for the first time prepared by using rice husks as a sustainable silicon source. The flower-like morphology, interconnected ultrathin nanosheets structure and high specific surface area endowed them with versatile applications. Magnesium silicate was used as an adsorbent with the maximum adsorption capacities of 557.9, 381.3, and 482.8mg/g for Pb 2+ , tetracycline (TC), and UO 2 2+ , respectively. Ni nanoparticles/silica (Ni NPs/SiO 2 ) exhibited high catalytic activity and good stability for 4-nitrophenol (4-NP) reduction within only ∼160s, which can be attributed to the ultra-small particle size (∼6.8nm), good dispersion and high loading capacity of Ni NPs. Considering the abundance and renewability of rice husks, metal silicate with complex architecture can be easily produced at a large scale and become a sustainable and reliable resource for multifunctional applications. Copyright © 2016 Elsevier B.V. All rights reserved.
Stanish, Heidi I; Curtin, Carol; Must, Aviva; Phillips, Sarah; Maslin, Melissa; Bandini, Linda G
2016-01-01
Youths with intellectual disabilities (ID) exhibit low levels of physical activity, but the underlying contributors to behavior are unclear. We compared physical activity enjoyment, perceived barriers, beliefs, and self-efficacy among adolescents with ID and typically developing (TD) adolescents. A questionnaire was administered to 38 adolescents with ID (mean age, 16.8 years) and 60 TD adolescents (mean age, 15.3 years). Of the original 33 questionnaire items, 23 met the test-retest reliability criteria and were included in the group comparisons. Fewer adolescents with ID reported that they have someone with whom to do physical activity (64% vs 93%: P < .001), and a greater percentage of adolescents with ID perceived that physical activities were too hard to learn (41% vs 0%; P < .001). Fewer adolescents with ID believed that physical activity would be good for their health (92% vs 100%; P = .05). More adolescents with ID reported a dislike of individual physical activities (P = .02). A large percentage of adolescents with ID (84%) responded that they were good at doing physical activities, but the difference between groups was only of borderline significance (95% of TD adolescents, P = .06). Adolescents shared many of the same perceptions about physical activity, but some important differences between groups were identified.
Sonar Transducer Reliability Improvement Program (STRIP)
1981-01-01
Fair *[51] EPDM NORDOL 1370 - Poor *[511 NATURAL 1155- Poor *[51] NITRILE 6100 - Good *[51] VITON CTBN (BF635075) - Poor *[511 CORK- RUBBER ... aging problems have been found. A report entitled "Reliability and Service Life Concepts for Sonar Transducer Applications" has been completed. - A draft...or aging problems have been found. See Section 9. * A report entitled "Reliability and Service Life Concepts for Sonar Transducer Applications" has
Lo, Wing-Sze; Ho, Sai-Yin; Wong, Bonny Yee-Man; Mak, Kwok-Kei; Lam, Tai-Hing
2011-06-01
The reliability and validity of Stunkard's Figure Rating Scale (FRS) as a measure of current body size (CBS) was established in Western adolescent girls but not in non-Western population. We examined the validity and test-retest reliability of Stunkard's FRS in assessing CBS among Chinese adolescents. Methods. In a school-based survey in Hong Kong, 5666 adolescents (boys: 45.1%; mean age 14.7 years) provided data on self-reported height and weight, CBS, perceived weight status, and health-related quality of life using the Medical Outcomes Study Short-Form version 2 (SF-12v2). Height and weight were also objectively measured. Spearman's correlation was used to assess construct validity, concurrent validity and test-retest reliability. Convergent and discriminant validity were good: CBS correlated strongly with weight and self-reported/measured BMI, but only weakly with SF-12v2. CBS correlated strongly with perceived weight status, showing concurrent validity. Spearman's correlation (r) for CBS was 0.78 for girls and 0.72 for boys indicating good test-retest reliability. Validity and reliability results did not differ significantly between senior and junior grade adolescents. Our findings support the use of Stunkard's FRS to measure body size among Chinese adolescents.
Fatigue in children: reliability and validity of the Dutch PedsQL™ Multidimensional Fatigue Scale.
Gordijn, M Suzanne; Suzanne Gordijn, M; Cremers, Eline M P; Kaspers, Gertjan J L; Gemke, Reinoud J B J
2011-09-01
The aim of the study is to report on the feasibility, reliability, validity, and the norm-references of the Dutch version of the PedsQL™ Multidimensional Fatigue Scale. The study participants are four hundred and ninety-seven parents of children aged 2-18 years and 366 children aged 5-18 years from various day care facilities, elementary schools, and a high school who completed the Dutch version of the PedsQL™ Multidimensional Fatigue Scale. The number of missing items was minimal. All scales showed satisfactory internal consistency reliability, with Cronbach's coefficient alpha exceeding 0.70. Test-retest reliability was good to excellent (ICCs 0.68-0.84) and inter-observer reliability varied from moderate to excellent (ICCs 0.56-0.93) for total scores. Parent/child concordance for total scores was poor to good (ICCs 0.25-0.68). The PedsQL™ Multidimensional Fatigue Scale was able to distinguish between healthy children and children with an impaired health condition. The Dutch version of the PedsQL™ Multidimensional Fatigue Scale demonstrates an adequate feasibility, reliability, and validity in another sociocultural context. With the obtained norm-references, it can be utilized as a tool in the evaluation of fatigue in healthy and chronically ill children aged 2-18 years.
Moghadam, Manije; Salavati, Mahyar; Sahaf, Robab; Rassouli, Maryam; Moghadam, Mojgan; Kamrani, Ahmad Ali Akbari
2018-03-01
After forward-backward translation, the LSS was administered to 334 Persian speaking, cognitively healthy elderly aged 60 years and over recruited through convenience sampling. To analyze the validity of the model's constructs and the relationships between the constructs, a confirmatory factor analysis followed by PLS analysis was performed. The Construct validity was further investigated by calculating the correlations between the LSS and the "Short Form Health Survey" (SF-36) subscales measuring similar and dissimilar constructs. The LSS was re-administered to 50 participants a month later to assess the reliability. For the eight-factor model of the life satisfaction construct, adequate goodness of fit between the hypothesized model and the model derived from the sample data was attained (positive and statistically significant beta coefficients, good R-squares and acceptable GoF). Construct validity was supported by convergent and discriminant validity, and correlations between the LSS and SF-36 subscales. Minimum Intraclass Correlation Coefficient level of 0.60 was exceeded by all subscales. Minimum level of reliability indices (Cronbach's α, composite reliability and indicator reliability) was exceeded by all subscales. The Persian-version of the Life Satisfaction Scale is a reliable and valid instrument, with psychometric properties which are consistent with the original version.
Investigation of improving MEMS-type VOA reliability
NASA Astrophysics Data System (ADS)
Hong, Seok K.; Lee, Yeong G.; Park, Moo Y.
2003-12-01
MEMS technologies have been applied to a lot of areas, such as optical communications, Gyroscopes and Bio-medical components and so on. In terms of the applications in the optical communication field, MEMS technologies are essential, especially, in multi dimensional optical switches and Variable Optical Attenuators(VOAs). This paper describes the process for the development of MEMS type VOAs with good optical performance and improved reliability. Generally, MEMS VOAs have been fabricated by silicon micro-machining process, precise fibre alignment and sophisticated packaging process. Because, it is composed of many structures with various materials, it is difficult to make devices reliable. We have developed MEMS type VOSs with many failure mode considerations (FMEA: Failure Mode Effect Analysis) in the initial design step, predicted critical failure factors and revised the design, and confirmed the reliability by preliminary test. These predicted failure factors were moisture, bonding strength of the wire, which wired between the MEMS chip and TO-CAN and instability of supplied signals. Statistical quality control tools (ANOVA, T-test and so on) were used to control these potential failure factors and produce optimum manufacturing conditions. To sum up, we have successfully developed reliable MEMS type VOAs with good optical performances by controlling potential failure factors and using statistical quality control tools. As a result, developed VOAs passed international reliability standards (Telcodia GR-1221-CORE).
Investigation of improving MEMS-type VOA reliability
NASA Astrophysics Data System (ADS)
Hong, Seok K.; Lee, Yeong G.; Park, Moo Y.
2004-01-01
MEMS technologies have been applied to a lot of areas, such as optical communications, Gyroscopes and Bio-medical components and so on. In terms of the applications in the optical communication field, MEMS technologies are essential, especially, in multi dimensional optical switches and Variable Optical Attenuators(VOAs). This paper describes the process for the development of MEMS type VOAs with good optical performance and improved reliability. Generally, MEMS VOAs have been fabricated by silicon micro-machining process, precise fibre alignment and sophisticated packaging process. Because, it is composed of many structures with various materials, it is difficult to make devices reliable. We have developed MEMS type VOSs with many failure mode considerations (FMEA: Failure Mode Effect Analysis) in the initial design step, predicted critical failure factors and revised the design, and confirmed the reliability by preliminary test. These predicted failure factors were moisture, bonding strength of the wire, which wired between the MEMS chip and TO-CAN and instability of supplied signals. Statistical quality control tools (ANOVA, T-test and so on) were used to control these potential failure factors and produce optimum manufacturing conditions. To sum up, we have successfully developed reliable MEMS type VOAs with good optical performances by controlling potential failure factors and using statistical quality control tools. As a result, developed VOAs passed international reliability standards (Telcodia GR-1221-CORE).
Siafarikas, F; Staer-Jensen, J; Braekken, I H; Bø, K; Engh, M Ellström
2013-03-01
To evaluate the learning process for acquiring three- and four-dimensional (3D/4D) transperineal ultrasound volumes of the levator hiatus (LH) dimensions at rest, during pelvic floor muscle (PFM) contraction and on Valsalva maneuver, and for analyzing the ultrasound volumes, as well as to perform an interobserver reliability study between two independent ultrasound examiners. This was a prospective study including 22 women. We monitored the learning process of an inexperienced examiner (IE) performing 3D/4D transperineal ultrasonography and analyzing the volumes. The examination included acquiring volumes during three PFM contractions and three Valsalva maneuvers. LH dimensions were determined in the axial plane. The learning process was documented by estimating agreement between the IE and an experienced examiner (E) using the intraclass correlation coefficient. Agreement was calculated in blocks of 10 ultrasound examinations and analyzed volumes. After the learning process was complete the interobserver reliability for the technique was calculated between these two independent examiners. For offline analysis of the first 10 ultrasound volumes obtained by E, good to very good agreement between E and IE was achieved for all LH measurements except for the left and right levator-urethra gap and pubic arc. For the next 10 analyzed volumes, agreement improved for all LH measurements. Volumes that had been obtained by IE and E were then re-evaluated by IE, and good to very good agreement was found for all LH measurements indicating consistency in volume acquisition. The interobserver reliability study showed excellent ICC values (ICC, 0.81-0.97) for all LH measurements except the pubic arc (ICC = 0.67). 3D/4D transperineal ultrasound is a reliable technique that can be learned in a short period of time. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.
Reliability and validity of a new scale on internal coherence (ICS) of cancer patients
Kröz, Matthias; Büssing, Arndt; von Laue, Hans Broder; Reif, Marcus; Feder, Gene; Schad, Friedemann; Girke, Matthias; Matthes, Harald
2009-01-01
Background Current inventories on quality of life used in oncology mainly focus on functional aspects of patients in the context of disease adaption and treatments (side) effects (EORTC QLQ C30) or generically the status of common functions (Medical Outcome Study SF 36). Beyond circumscribed dimensions of quality of life (i.e., physical, emotional, social, cognitive etc.), there is a lack of inventories which also address other relevant dimensions such as the 'sense of coherence' (SOC) in cancer patients. SOC is important because of its potential prognostic relevance in cancer patients, but the current SOC scale has mainly been validated for psychiatric and psychosomatic patients. Our two-step validation study addresses the internal coherence (ICS) scale, which is based on expert rating, using specific items for oncological patients, with respect to its reliability, validity and sensitivity to chemotherapy. Methods The items were tested on 114 participants (57 cancer patients and a matched control group), alongside questions on autonomic regulation (aR), the Hospital Anxiety and Depression Scale (HADS), self-regulation (SRQ) and Karnofsky the Performance-Index (KPI). A retest of 65 participants was carried out after a median time span of four weeks. In the second part of the study, the ICS was used to assess internal coherence during chemotherapy in 25 patients with colorectal carcinoma (CRC) and 17 breast cancer patients. ICS was recorded before, during and 4 – 8 weeks after treatment. Results The 10-item scale of 'internal coherence' (ICS) shows good to very good reliability: Cronbach-α r = 0.91, retest-reliability r = 0.80. The ICS correlates with r = 0.43 – 0.72 to the convergence criteria (all p < 0.001). We are able to show decreased ICS-values after the third cycle for CRC and breast cancer patients, with a subsequent increase of ICS scores after the end of chemotherapy. Conclusion The ICS has good to very good reliability, validity and sensitivity to chemotherapy. PMID:19552807
76 FR 35031 - Notice of Quarterly Report (January 1, 2011-March 31, 2011)
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-15
... Number of farmers Profitability of trained in Commercial cultivation, Agriculture. services to Number of.... Knowledge of good hygiene practices. Households with reliable water services. Enterprises with reliable... by public outreach efforts. Personnel trained. Number of Services Fonciers Ruraux (rural land service...
Treating Cronbach's Alpha Reliability Coefficients as Data in Counseling Research
ERIC Educational Resources Information Center
Helms, Janet E.; Henze, Kevin T.; Sass, Terry L.; Mifsud, Venus A.
2006-01-01
Scientific associations and measurement experts in psychology and education have voiced various standards and best-practice recommendations concerning reliability data over the years. Yet in the counseling psychology literature, there is virtually no single-source compilation and articulation of good practices for reporting, analyzing, and…
Relational, Structural, and Semantic Analysis of Graphical Representations and Concept Maps
ERIC Educational Resources Information Center
Ifenthaler, Dirk
2010-01-01
The demand for good instructional environments presupposes valid and reliable analytical instruments for educational research. This paper introduces the "SMD Technology" (Surface, Matching, Deep Structure), which measures relational, structural, and semantic levels of graphical representations and concept maps. The reliability and validity of the…
Validation of the Short Form of the Academic Procrastination Scale.
Yockey, Ronald D
2016-02-01
The factor structure, internal consistency reliability, and convergent validity of the five-item Academic Procrastination Scale-Short Form was investigated on an ethnically diverse sample of college students. The results provided support for the Academic Procrastination Scale-Short Form as a unidimensional measure of academic procrastination, which possessed good internal consistency reliability in this sample of 282 students. The scale also demonstrated good convergent validity, with moderate to large correlations with both the Procrastination Assessment Scale-Students and the Tuckman Procrastination Scale. Implications of the results are discussed and recommendations for future work provided.
Reliability testing of the Larsen and Sharp classifications for rheumatoid arthritis of the elbow.
Jew, Nicholas B; Hollins, Anthony M; Mauck, Benjamin M; Smith, Richard A; Azar, Frederick M; Miller, Robert H; Throckmorton, Thomas W
2017-01-01
Two popular systems for classifying rheumatoid arthritis affecting the elbow are the Larsen and Sharp schemes. To our knowledge, no study has investigated the reliability of these 2 systems. We compared the intraobserver and interobserver agreement of the 2 systems to determine whether one is more reliable than the other. The radiographs of 45 patients diagnosed with rheumatoid arthritis affecting the elbow were evaluated. Anteroposterior and lateral radiographs were deidentified and distributed to 6 evaluators (4 fellowship-trained upper extremity surgeons and 2 orthopedic trainees). Each evaluator graded all 45 radiographs according to the Larsen and Sharp scoring methods on 2 occasions, at least 2 weeks apart. Overall intraobserver reliability was 0.93 (95% confidence interval [CI], 0.90-0.95) for the Larsen system and 0.92 (95% CI, 0.86-0.96) for the Sharp classification, both indicating substantial agreement. Overall interobserver reliability was 0.70 (95% CI, 0.60-0.80) for the Larsen classification and 0.68 (95% CI, 0.54-0.81) for the Sharp system, both indicating good agreement. There were no significant differences in the intraobserver or interobserver reliability of the systems overall and no significant differences in reliability between attending surgeons and trainees for either classification system. The Larsen and Sharp systems both show substantial intraobserver reliability and good interobserver agreement for the radiographic classification of rheumatoid arthritis affecting the elbow. Differences in training level did not result in substantial variances in reliability for either system. We conclude that both systems can be reliably used to evaluate rheumatoid arthritis of the elbow by observers of varying training levels. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
HIDECKER, MARY JO COOLEY; PANETH, NIGEL; ROSENBAUM, PETER L; KENT, RAYMOND D; LILLIE, JANET; EULENBERG, JOHN B; CHESTER, KEN; JOHNSON, BRENDA; MICHALSEN, LAUREN; EVATT, MORGAN; TAYLOR, KARA
2011-01-01
Aim The purpose of this study was to create and validate a Communication Function Classification System (CFCS) for children with cerebral palsy (CP) that can be used by a wide variety of individuals who are interested in CP. This paper reports the content validity, interrater reliability, and test–retest reliability of the CFCS for children with CP. Method An 11-member development team created comprehensive descriptions of the CFCS levels, and four nominal groups comprising 27 participants critiqued these levels. Within a Delphi survey, 112 participants commented on the clarity and usefulness of the CFCS. Interrater reliability was completed by 61 professionals and 68 parents/relatives who classified 69 children with CP aged 2 to 18 years. Test–retest reliability was completed by 48 professionals who allowed at least 2 weeks between classifications. The participants who assessed the CFCS were all relevant stakeholders: adults with CP, parents of children with CP, educators, occupational therapists, physical therapists, physicians, and speech–language pathologists. Results The interrater reliability of the CFCS was 0.66 between two professionals and 0.49 between a parent and a professional. Professional interrater reliability improved to 0.77 for classification of children older than 4 years. The test–retest reliability was 0.82. Interpretation The CFCS demonstrates content validity and shows very good test–retest reliability, good professional interrater reliability, and moderate parent–professional interrater reliability. Combining the CFCS with the Gross Motor Function Classification System and the Manual Ability Classification System contributes to a functional performance view of daily life for individuals with CP, in accordance with the World Health Organization’s International Classification of Functioning, Disability and Health. PMID:21707596
How Many Sleep Diary Entries Are Needed to Reliably Estimate Adolescent Sleep?
Arora, Teresa; Gradisar, Michael; Taheri, Shahrad; Carskadon, Mary A.
2017-01-01
Abstract Study Objectives: To investigate (1) how many nights of sleep diary entries are required for reliable estimates of five sleep-related outcomes (bedtime, wake time, sleep onset latency [SOL], sleep duration, and wake after sleep onset [WASO]) and (2) the test–retest reliability of sleep diary estimates of school night sleep across 12 weeks. Methods: Data were drawn from four adolescent samples (Australia [n = 385], Qatar [n = 245], United Kingdom [n = 770], and United States [n = 366]), who provided 1766 eligible sleep diary weeks for reliability analyses. We performed reliability analyses for each cohort using complete data (7 days), one to five school nights, and one to two weekend nights. We also performed test–retest reliability analyses on 12-week sleep diary data available from a subgroup of 55 US adolescents. Results: Intraclass correlation coefficients for bedtime, SOL, and sleep duration indicated good-to-excellent reliability from five weekday nights of sleep diary entries across all adolescent cohorts. Four school nights was sufficient for wake times in the Australian and UK samples, but not the US or Qatari samples. Only Australian adolescents showed good reliability for two weekend nights of bedtime reports; estimates of SOL were adequate for UK adolescents based on two weekend nights. WASO was not reliably estimated using 1 week of sleep diaries. We observed excellent test–rest reliability across 12 weeks of sleep diary data in a subsample of US adolescents. Conclusion: We recommend at least five weekday nights of sleep dairy entries to be made when studying adolescent bedtimes, SOL, and sleep duration. Adolescent sleep patterns were stable across 12 consecutive school weeks. PMID:28199718
How Many Sleep Diary Entries Are Needed to Reliably Estimate Adolescent Sleep?
Short, Michelle A; Arora, Teresa; Gradisar, Michael; Taheri, Shahrad; Carskadon, Mary A
2017-03-01
To investigate (1) how many nights of sleep diary entries are required for reliable estimates of five sleep-related outcomes (bedtime, wake time, sleep onset latency [SOL], sleep duration, and wake after sleep onset [WASO]) and (2) the test-retest reliability of sleep diary estimates of school night sleep across 12 weeks. Data were drawn from four adolescent samples (Australia [n = 385], Qatar [n = 245], United Kingdom [n = 770], and United States [n = 366]), who provided 1766 eligible sleep diary weeks for reliability analyses. We performed reliability analyses for each cohort using complete data (7 days), one to five school nights, and one to two weekend nights. We also performed test-retest reliability analyses on 12-week sleep diary data available from a subgroup of 55 US adolescents. Intraclass correlation coefficients for bedtime, SOL, and sleep duration indicated good-to-excellent reliability from five weekday nights of sleep diary entries across all adolescent cohorts. Four school nights was sufficient for wake times in the Australian and UK samples, but not the US or Qatari samples. Only Australian adolescents showed good reliability for two weekend nights of bedtime reports; estimates of SOL were adequate for UK adolescents based on two weekend nights. WASO was not reliably estimated using 1 week of sleep diaries. We observed excellent test-rest reliability across 12 weeks of sleep diary data in a subsample of US adolescents. We recommend at least five weekday nights of sleep dairy entries to be made when studying adolescent bedtimes, SOL, and sleep duration. Adolescent sleep patterns were stable across 12 consecutive school weeks. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.
van der Laan, Tallie M J; Postema, Sietke G; Reneman, Michiel F; Bongers, Raoul M; van der Sluis, Corry K
2018-02-10
Reliability study. Quantifying compensatory movements during work-related tasks may help to prevent musculoskeletal complaints in individuals with upper limb absence. (1) To develop a qualitative scoring system for rating compensatory shoulder and trunk movements in upper limb prosthesis wearers during the performance of functional capacity evaluation tests adjusted for use by 1-handed individuals (functional capacity evaluation-one handed [FCE-OH]); (2) to examine the interrater and intrarater reliability of the scoring system; and (3) to assess its feasibility. Movement patterns of 12 videotaped upper limb prosthesis wearers and 20 controls were analyzed. Compensatory movements were defined for each FCE-OH test, and a scoring system was developed, pilot tested, and adjusted. During reliability testing, 18 raters (12 FCE experts and 6 physiotherapists/gait analysts) scored videotapes of upper limb prosthesis wearers performing 4 FCE-OH tests 2 times (2 weeks apart). Agreement was expressed in % and kappa value. Feasibility (focus area's "acceptability", "demand," and "implementation") was determined by using a questionnaire. After 2 rounds of pilot testing and adjusting, reliability of a third version was tested. The interrater reliability for the first and second rating sessions were к = 0.54 (confidence interval [CI]: 0.52-0.57) and к = 0.64 (CI: 0.61-0.66), respectively. The intrarater reliability was к = 0.77 (CI: 0.72-0.82). The feasibility was good but could be improved by a training program. It seems possible to identify compensatory movements in upper limb prosthesis wearers during the performance of FCE-OH tests reliably by observation using the developed observational scoring system. Interrater reliability was satisfactory in most instances; intrarater reliability was good. Feasibility was established. Copyright © 2018 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.
Kvistgaard Olsen, Jack; Fener, Dilay Kesgin; Waehrens, Eva Elisabet; Wulf Christensen, Anton; Jespersen, Anders; Danneskiold-Samsøe, Bente; Bartels, Else Marie
2017-07-01
Computerized pneumatic cuff pressure algometry (CPA) using the DoloCuff is a new method for pain assessment. Intra- and inter-rater reliabilities have not yet been established. Our aim was to examine the inter- and intrarater reliabilities of DoloCuff measures in healthy subjects. Twenty healthy subjects (ages 20 to 29 years) were assessed three times at 24-hour intervals by two trained raters. Inter-rater reliability was established based on the first and second assessments, whereas intrarater reliability was based on the second and third assessments. Subjects were randomized 1:1 to first assessment at either rater 1 or rater 2. The variables of interest were pressure pain threshold (PT), pressure pain tolerance (PTol), and temporal summation index (TSI). Reliability was estimated by a two-way mixed intraclass correlation coefficient (ICC) absolute agreement analysis. Reliability was considered excellent if ICC > 0.75, fair to good if 0.4 < ICC < 0.75, and poor if ICC < 0.4. Bias and random errors between raters and assessments were evaluated using 95% confidence interval (CI) and Bland-Altman plots. Inter-rater reliability for PT, PTol, and TSI was 0.88 (95% CI: 0.69 to 0.95), 0.86 (95% CI: 0.65 to 0.95), and 0.81 (95% CI: 0.42 to 0.94), respectively. The intrarater reliability for PT, PTol, and TSI was 0.81 (95% CI: 0.53 to 0.92), 0.89 (95% CI: 0.74 to 0.96), and 0.75 (95% CI: 0.28 to 0.91), respectively. Inter-rater reliability was excellent for PT, PTol, and TSI. Similarly, the intrarater reliability for PT and PTol was excellent, while borderline excellent/good for TSI. Therefore, the DoloCuff can be used to obtain reliable measures of pressure pain parameters in healthy subjects. © 2016 World Institute of Pain.
Johansson, Fredrik R.; Skillgate, Eva; Lapauw, Mattis L.; Clijmans, Dorien; Deneulin, Valentijn P.; Palmans, Tanneke; Engineer, Human Kinetic; Cools, Ann M.
2015-01-01
Context Shoulder strength assessment plays an important role in the clinical examination of the shoulder region. Eccentric strength measurements are of special importance in guiding the clinician in injury prevention or return-to-play decisions after injury. Objective To examine the absolute and relative reliability and validity of a standardized eccentric strength-measurement protocol for the glenohumeral external rotators. Design Descriptive laboratory study. Setting Testing environment at the Department of Rehabilitation Sciences and Physiotherapy of Ghent University, Belgium. Patients or Other Participants Twenty-five healthy participants (9 men and 16 women) without any history of shoulder pain were tested by 2 independent assessors using a handheld dynamometer (HHD) and underwent an isokinetic testing procedure. Intervention(s) The clinical protocol used an HHD, a DynaPort accelerometer to measure acceleration and angular velocity of testing 30°/s over 90° of range of motion, and a Biodex dynamometer to measure isokinetic activity. Main Outcome Measure(s) Three eccentric strength measurements: (1) tester 1 with the HHD, (2) tester 2 with the HHD, and (3) Biodex isokinetic strength measurement. Results The intratester reliability was excellent (0.879 and 0.858), whereas the intertester reliability was good, with an intraclass correlation coefficient between testers of 0.714. Pearson product moment correlation coefficients of 0.78 and 0.70 were noted between the HHD and the isokinetic data, showing good validity of this new procedure. Conclusions Standardized eccentric rotator cuff strength can be tested and measured in the clinical setting with good-to-excellent reliability and validity using an HHD. PMID:25974381
Brinca, Lilia; Batista, Ana Paula; Tavares, Ana Inês; Pinto, Patrícia N; Araújo, Lara
2015-11-01
The main objective of the present study was to investigate if the type of voice stimuli-sustained vowel, oral reading, and connected speech-results in good intrarater and interrater agreement/reliability. A short-term panel study was performed. Voice samples from 30 native European Portuguese speakers were used in the present study. The speech materials used were (1) the sustained vowel /a/, (2) oral reading of the European Portuguese version of "The Story of Arthur the Rat," and (3) connected speech. After an extensive training with textual and auditory anchors, the judges were asked to rate the severity of dysphonic voice stimuli using the phonation dimensions G, R, and B from the GRBAS scale. The voice samples were judged 6 months and 1 year after the training. Intrarater agreement and reliability were generally very good for all the phonation dimensions and voice stimuli. The highest interrater reliability was obtained using the oral reading stimulus, particularly for phonation dimensions grade (G) and breathiness (B). Roughness (R) was the voice quality that was the most difficult to evaluate, leading to interrater unreliability in all voice quality ratings. Extensive training using textual and auditory anchors and the use of anchors during the voice evaluations appear to be good methods for auditory-perceptual evaluation of dysphonic voices. The best results of interrater reliability were obtained when the oral reading stimulus was used. Breathiness appears to be a voice quality that is easier to evaluate than roughness. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Pizzini, Matias; Robinson, Ashley; Yanez, Dania; Hanney, William J.
2013-01-01
Purpose/Aim: This purpose of this study was to investigate the reliability, minimal detectable change (MDC), and concurrent validity of active spinal mobility measurements using a gravity‐based bubble inclinometer and iPhone® application. Materials/Methods: Two investigators each used a bubble inclinometer and an iPhone® with inclinometer application to measure total thoracolumbo‐pelvic flexion, isolated lumbar flexion, total thoracolumbo‐pelvic extension, and thoracolumbar lateral flexion in 30 asymptomatic participants using a blinded repeated measures design. Results: The procedures used in this investigation for measuring spinal mobility yielded good intrarater and interrater reliability with Intraclass Correlation Coefficients (ICC) for bubble inclinometry ≥ 0.81 and the iPhone® ≥ 0.80. The MDC90 for the interrater analysis ranged from 4° to 9°. The concurrent validity between bubble inclinometry and the iPhone® application was good with ICC values of ≥ 0.86. The 95% level of agreement indicates that although these measuring instruments are equivalent individual differences of up to 18° may exist when using these devices interchangeably. Conclusions: The bubble inclinometer and iPhone® possess good intrarater and interrater reliability as well as concurrent validity when strict measurement procedures are adhered to. This study provides preliminary evidence to suggest that smart phone applications may offer clinical utility comparable to inclinometry for quantifying spinal mobility. Clinicians should be aware of the potential disagreement when using these devices interchangeably. Level of Evidence: 2b (Observational study of reliability) PMID:23593551
Kolber, Morey J; Pizzini, Matias; Robinson, Ashley; Yanez, Dania; Hanney, William J
2013-04-01
PURPOSEAIM: This purpose of this study was to investigate the reliability, minimal detectable change (MDC), and concurrent validity of active spinal mobility measurements using a gravity-based bubble inclinometer and iPhone® application. MATERIALSMETHODS: Two investigators each used a bubble inclinometer and an iPhone® with inclinometer application to measure total thoracolumbo-pelvic flexion, isolated lumbar flexion, total thoracolumbo-pelvic extension, and thoracolumbar lateral flexion in 30 asymptomatic participants using a blinded repeated measures design. The procedures used in this investigation for measuring spinal mobility yielded good intrarater and interrater reliability with Intraclass Correlation Coefficients (ICC) for bubble inclinometry ≥ 0.81 and the iPhone® ≥ 0.80. The MDC90 for the interrater analysis ranged from 4° to 9°. The concurrent validity between bubble inclinometry and the iPhone® application was good with ICC values of ≥ 0.86. The 95% level of agreement indicates that although these measuring instruments are equivalent individual differences of up to 18° may exist when using these devices interchangeably. The bubble inclinometer and iPhone® possess good intrarater and interrater reliability as well as concurrent validity when strict measurement procedures are adhered to. This study provides preliminary evidence to suggest that smart phone applications may offer clinical utility comparable to inclinometry for quantifying spinal mobility. Clinicians should be aware of the potential disagreement when using these devices interchangeably. 2b (Observational study of reliability).
Salamh, Paul A; Kolber, Morey
2014-01-01
To investigate the reliability, minimal detectable change (MDC90) and concurrent validity of a gravity-based bubble inclinometer (inclinometer) and iPhone® application for measuring standing lumbar lordosis. Two investigators used both an inclinometer and an iPhone® with an inclinometer application to measure lumbar lordosis of 30 asymptomatic participants. ICC models 3,k and 2,k were used for the intrarater and interrater analysis, respectively. Good interrater and intrarater reliability was present for the inclinometer with Intraclass Correlation Coefficients (ICC) of 0.90 and 0.85, respectively and the iPhone® application with ICC values of 0.96 and 0.81. The minimal detectable change (MDC90) indicates that a change greater than or equal to 7° and 6° is needed to exceed the threshold of error using the iPhone® and inclinometer, respectively. The concurrent validity between the two instruments was good with a Pearson product-moment coefficient of correlation (r) of 0.86 for both raters. Ninety-five percent limits of agreement identified differences ranging from 9° greater in regards to the iPhone® to 8° less regarding the inclinometer. Both the inclinometer and iPhone® application possess good interrater reliability, intrarater reliability and concurrent validity for measuring standing lumbar lordosis. This investigation provides preliminary evidence to suggest that smart phone applications may offer clinical utility comparable to inclinometry for quantifying standing lumbar lordosis. Clinicians should recognize potential individual differences when using these devices interchangeably.
NASA Astrophysics Data System (ADS)
Serevina, V.; Muliyati, D.
2018-05-01
This research aims to develop students’ performance assessment instrument based on scientific approach is valid and reliable in assessing the performance of students on basic physics lab of Simple Harmonic Motion (SHM). This study uses the ADDIE consisting of stages: Analyze, Design, Development, Implementation, and Evaluation. The student performance assessment developed can be used to measure students’ skills in observing, asking, conducting experiments, associating and communicate experimental results that are the ‘5M’ stages in a scientific approach. Each grain of assessment in the instrument is validated by the instrument expert and the evaluation with the result of all points of assessment shall be eligible to be used with a 100% eligibility percentage. The instrument is then tested for the quality of construction, material, and language by panel (lecturer) with the result: 85% or very good instrument construction aspect, material aspect 87.5% or very good, and language aspect 83% or very good. For small group trial obtained instrument reliability level of 0.878 or is in the high category, where r-table is 0.707. For large group trial obtained instrument reliability level of 0.889 or is in the high category, where r-table is 0.320. Instruments declared valid and reliable for 5% significance level. Based on the result of this research, it can be concluded that the student performance appraisal instrument based on the developed scientific approach is declared valid and reliable to be used in assessing student skill in SHM experimental activity.
Reliability and type of consumer health documents on the World Wide Web: an annotation study.
Martin, Melanie J
2011-01-01
In this paper we present a detailed scheme for annotating medical web pages designed for health care consumers. The annotation is along two axes: first, by reliability (the extent to which the medical information on the page can be trusted), second, by the type of page (patient leaflet, commercial, link, medical article, testimonial, or support). We analyze inter-rater agreement among three judges for each axis. Inter-rater agreement was moderate (0.77 accuracy, 0.62 F-measure, 0.49 Kappa) on the page reliability axis and good (0.81 accuracy, 0.72 F-measure, 0.73 Kappa) along the page type axis. We have shown promising results in this study that appropriate classes of pages can be developed and used by human annotators to annotate web pages with reasonable to good agreement. No.
Measuring theory of mind in children. Psychometric properties of the ToM Storybooks.
Blijd-Hoogewys, E M A; van Geert, P L C; Serra, M; Minderaa, R B
2008-11-01
Although research on Theory-of-Mind (ToM) is often based on single task measurements, more comprehensive instruments result in a better understanding of ToM development. The ToM Storybooks is a new instrument measuring basic ToM-functioning and associated aspects. There are 34 tasks, tapping various emotions, beliefs, desires and mental-physical distinctions. Four studies on the validity and reliability of the test are presented, in typically developing children (n = 324, 3-12 years) and children with PDD-NOS (n = 30). The ToM Storybooks have good psychometric qualities. A component analysis reveals five components corresponding with the underlying theoretical constructs. The internal consistency, test-retest reliability, inter-rater reliability, construct validity and convergent validity are good. The ToM Storybooks can be used in research as well as in clinical settings.
Reliability of self-reported antisocial personality disorder symptoms among substance abusers.
Cottler, L B; Compton, W M; Ridenour, T A; Ben Abdallah, A; Gallagher, T
1998-02-01
It is estimated that from 20 to 60% of substance abusers meet criteria for Antisocial Personality Disorder (APD). An accurate and reliable diagnosis is important because persons meeting criteria for APD, by the nature of their disorder, are less likely to change behaviors and more likely to relapse to both substance abuse and high risk behaviors. To understand more about the reliability of the disorder and symptoms of APD, the Diagnostic Interview Schedule Version III-R (DIS) was administered to 453 substance abusers ascertained from treatment programs and from the general population (St Louis Epidemiological Catchment Area (ECA) follow-up study). Estimates of the 1 week, test-retest reliability for the childhood conduct disorder criterion, the adult antisocial behavior criterion, and APD diagnosis fell in the good agreement range, as measured by kappa. The internal consistency of these DIS symptoms was adequate to acceptable. Individual DIS criteria designed to measure childhood conduct disorder ranged from fair to good for most items; reliability was slightly higher for the adult antisocial behavior symptom items. Finally, self-reported 'liars' were no more unreliable in their reports of their behaviors than 'non-liars'.
Figueroa, José; Guarachi, Juan Pablo; Matas, José; Arnander, Magnus; Orrego, Mario
2016-04-01
Computed tomography (CT) is widely used to assess component rotation in patients with poor results after total knee arthroplasty (TKA). The purpose of this study was to simultaneously determine the accuracy and reliability of CT in measuring TKA component rotation. TKA components were implanted in dry-bone models and assigned to two groups. The first group (n = 7) had variable femoral component rotations, and the second group (n = 6) had variable tibial tray rotations. CT images were then used to assess component rotation. Accuracy of CT rotational assessment was determined by mean difference, in degrees, between implanted component rotation and CT-measured rotation. Intraclass correlation coefficient (ICC) was applied to determine intra-observer and inter-observer reliability. Femoral component accuracy showed a mean difference of 2.5° and the tibial tray a mean difference of 3.2°. There was good intra- and inter-observer reliability for both components, with a femoral ICC of 0.8 and 0.76, and tibial ICC of 0.68 and 0.65, respectively. CT rotational assessment accuracy can differ from true component rotation by approximately 3° for each component. It does, however, have good inter- and intra-observer reliability.
Rahman, Azriani Ab; Mohamad, Norsarwany; Imran, Musa Kamarul; Ibrahim, Wan Pauzi Wan; Othman, Azizah; Aziz, Aniza Abd; Harith, Sakinah; Ibrahim, Mohd Ismail; Ariffin, Nor Hashimah; Van Rostenberghe, Hans
2011-01-01
Background: No previous study has assessed the impact of childhood disability on parents and family in the context of Malaysia, and no instrument to measure this impact has previously been available. The objective of this cross-sectional study was to determine the reliability of a Malay version of the PedsQL™ Family Impact Module that measures the impact of children with disabilities (CWD) on their parents and family in a Malaysian context. Methods: The study was conducted in 2009. The questionnaire was translated forward and backward before it was administered to 44 caregivers of CWD to determine the internal consistency reliability. The test for Cronbach’s alpha was performed. Results: The internal consistency reliability was good. The Cronbach’s alpha for all domains was above 0.7, ranging from 0.73 to 0.895. Conclusion: The Malay version of the PedsQL™ Family Impact Module showed evidence of good internal consistency reliability. However, future studies with a larger sample size are necessary before the module can be recommended as a tool to measure the impact of disability on Malay-speaking Malaysian families. PMID:22589674
Nerve ultrasound reliability of upper limbs: Effects of examiner training.
Garcia-Santibanez, Rocio; Dietz, Alexander R; Bucelli, Robert C; Zaidman, Craig M
2018-02-01
Duration of training to reliably measure nerve cross-sectional area with ultrasound is unknown. A retrospective review was performed of ultrasound data, acquired and recorded by 2 examiners-an expert and either a trainee with 2 months (novice) or a trainee with 12 months (experienced) of experience. Data on median, ulnar, and radial nerves were reviewed for 42 patients. Interrater reliability was good and varied most with nerve site but little with experience. Coefficient of variation (CoV) range was 9.33%-22.5%. Intraclass correlation coefficient (ICC) was good to excellent (0.65-95) except ulnar nerve-wrist/forearm and radial nerve-humerus (ICC = 0.39-0.59). Interrater differences did not vary with nerve size or body mass index. Expert-novice and expert-experienced interrater differences and CoV were similar. The ulnar nerve-wrist expert-novice interrater difference decreased with time (r s = -0.68, P = 0.001). A trainee with at least 2 months of experience can reliably measure upper limb nerves. Reliability varies by nerve and location and slightly improves with time. Muscle Nerve 57: 189-192, 2018. © 2017 Wiley Periodicals, Inc.
Validation of the Arabic Version of the Iowa Infant Feeding Attitude Scale among Lebanese Women.
Charafeddine, Lama; Tamim, Hani; Soubra, Marwa; de la Mora, Arlene; Nabulsi, Mona
2016-05-01
There is need in the Arab world for validated instruments that can reliably assess infant feeding attitudes among women. The 17-item Iowa Infant Feeding Attitude Scale (IIFAS) has consistently shown good reliability and validity in different cultures and the ability to predict breastfeeding intention and exclusivity. This study assessed the psychometric properties of the Arabic version of the IIFAS (IIFAS-A). After translating to classical Arabic and back-translating to English, the IIFAS-A was pilot tested among 20 women for comprehension, clarity, length, and cultural appropriateness. The IIFAS-A was then validated among 170 women enrolled in a breastfeeding promotion and support clinical trial in Lebanon. The IIFAS-A showed acceptable internal consistency reliability (Cronbach's α = 0.640), with principal components analysis revealing that it is unidimensional. The 17 items had good interitem reliabilities ranging between 0.599 and 0.665. The number of breastfed children was the only predictor of the overall IIFAS-A score in a multivariate stepwise regression model (β = 1.531, P < .0001). The 17-item IIFAS-A is a reliable and valid instrument for measuring women's infant feeding attitudes in the Arab context. © The Author(s) 2015.
Psychometric properties of the medical outcomes study sleep scale in Spanish postmenopausal women.
Zagalaz-Anula, Noelia; Hita-Contreras, Fidel; Martínez-Amat, Antonio; Cruz-Díaz, David; Lomas-Vega, Rafael
2017-07-01
This study aimed to analyze the reliability and validity of the Spanish version of the Medical Outcomes Study Sleep Scale (MOS-SS), and its ability to discriminate between poor and good sleepers among a Spanish population with vestibular disorders. In all, 121 women (50-76 years old) completed the Spanish version of the MOS-SS. Internal consistency, test-retest reliability, and construct validity (exploratory factor analysis) were analyzed. Concurrent validity was evaluated using the Pittsburgh Sleep Quality Index and the 36-item Short Form Health Survey. To analyze the ability of the MOS-SS scores to discriminate between poor and good sleepers, a receiver-operating characteristic curve analysis was performed. The Spanish version of the MOS-SS showed excellent and substantial reliability in Sleep Problems Index I (two sleep disturbance items, one somnolence item, two sleep adequacy items, and awaken short of breath or with headache) and Sleep Problems Index II (four sleep disturbance items, two somnolence items, two sleep adequacy items, and awaken short of breath or with headache), respectively, and good internal consistency with optimal Cronbach's alpha values in all domains and indexes (0.70-0.90). Factor analysis suggested a coherent four-factor structure (explained variance 70%). In concurrent validity analysis, MOS-SS indexes showed significant and strong correlation with the Pittsburgh Sleep Quality Index total score, and moderate with the 36-item Short Form Health Survey component summaries. Several domains and the two indexes were significantly able to discriminate between poor and good sleepers (P < 0.05). Optimal cut-off points were above 20 for "sleep disturbance" domain, with above 22.22 and above 33.33 for Sleep Problems Index I and II. The Spanish version of the MOS-SS is a valid and reliable instrument, suitable to assess sleep quality in Spanish postmenopausal women, with satisfactory general psychometric properties. It discriminates well between good and poor sleepers.
Reliability and construct validity of the College Student Stress Scale.
Feldt, Ronald C; Koch, Chris
2011-04-01
Reliability and construct validity of the 11-item College Student Stress Scale were investigated with exploratory (N = 273) and confirmatory factor analyses (N = 185) in undergraduate college students. Two factors were observed; however, reliability of the 3-item factor was too low and one item failed to load on either factor. A 7-item measure (Factor 1) had acceptable reliability (.81) and good convergence with the Perceived Stress Scale. This measure was significantly correlated with Neuroticism, Test Anxiety, and Self-efficacy for Learning, but not Social Desirability or age.
Wang, X; Jiao, Y; Tang, T; Wang, H; Lu, Z
2013-12-19
Intrinsic connectivity networks (ICNs) are composed of spatial components and time courses. The spatial components of ICNs were discovered with moderate-to-high reliability. So far as we know, few studies focused on the reliability of the temporal patterns for ICNs based their individual time courses. The goals of this study were twofold: to investigate the test-retest reliability of temporal patterns for ICNs, and to analyze these informative univariate metrics. Additionally, a correlation analysis was performed to enhance interpretability. Our study included three datasets: (a) short- and long-term scans, (b) multi-band echo-planar imaging (mEPI), and (c) eyes open or closed. Using dual regression, we obtained the time courses of ICNs for each subject. To produce temporal patterns for ICNs, we applied two categories of univariate metrics: network-wise complexity and network-wise low-frequency oscillation. Furthermore, we validated the test-retest reliability for each metric. The network-wise temporal patterns for most ICNs (especially for default mode network, DMN) exhibited moderate-to-high reliability and reproducibility under different scan conditions. Network-wise complexity for DMN exhibited fair reliability (ICC<0.5) based on eyes-closed sessions. Specially, our results supported that mEPI could be a useful method with high reliability and reproducibility. In addition, these temporal patterns were with physiological meanings, and certain temporal patterns were correlated to the node strength of the corresponding ICN. Overall, network-wise temporal patterns of ICNs were reliable and informative and could be complementary to spatial patterns of ICNs for further study. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.
Yang, Chien-Ming; Huang, Yu-Shu; Song, Yu-Chen
2010-04-01
The present study examined the psychometric properties of the Chinese version of the Pediatric Daytime Sleepiness Scale (PDSS) and the utility of the PDSS as a screening tool for pathological daytime sleepiness in teenagers with obstructive sleep apnea (OSA) and narcolepsy. The PDSS was first administered to 238 middle and high school students to assess the reliability of the scale, and then administered to 28 teenagers with OSA, 31 teenagers with narcolepsy, and 34 normal controls to evaluate its clinical utility. Test-retest reliability and internal consistency were acceptable. The PDSS scores were significantly higher in narcoleptic subjects than in subjects with OSA, and higher in OSA syndrome (OSAS) subjects than normal controls. Furthermore, the scores decreased in narcoleptic subjects after medical treatment. Both reliability and validity were proven to be good. As a screening tool for narcolepsy, receiver operator characteristic (ROC) curve analysis showed that the PDSS, with a cut-off score of 16/17, had good sensitivity (87.1%) and fair specificity (74.3%) for identifying individuals with narcolepsy. When used for screening OSA, however, the differentiating power was not as good. The PDSS is a reliable and valid tool for the measurement of sleepiness in clinical youth populations. When used as a screening tool, it is useful for sleep disorders involving more severe pathological sleepiness, as in narcolepsy.
76 FR 60536 - Notice of Quarterly Report (April 1, 2011-June 30, 2011)
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-29
... Number of farmers of cultivation, trained in commercial services to agriculture. agriculture and Number.... Knowledge of good hygiene practices. Households with reliable water services. Enterprises with reliable... Antananarivo. Average time for Land Services Offices to issue a duplicate copy of a title. Average cost to a...
76 FR 4929 - Agency Information Collection Activities: Entry of Articles for Exhibition.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-27
... Activities: Entry of Articles for Exhibition. AGENCY: U.S. Customs and Border Protection (CBP), Department of... requirement concerning the Entry of Articles for Exhibition (19 CFR 147.11(c)). This request for comment is...: Title: Entry of Articles for Exhibition. OMB Number: 1651-0037. Form Number: None. Abstract: Goods...
An Analytical Methodology for Predicting Repair Time Distributions of Advanced Technology Aircraft.
1985-12-01
1984. 3. Barlow, Richard E. "Mathematical Theory of Reliabilitys A Historical Perspective." ZEEE Transactions on Reliability, 33. 16-19 (April 1984...Technology (AU), Wright-Patterson AFB OH, March 1971. 11. Coppola, Anthony. "Reliability Engineering of J- , Electronic Equipment," ZEEE Transactions on...1982. 64. Woodruff, Brian W. at al. "Modified Goodness-o-Fit Tests for Gamma Distributions with Unknown Location and Scale Parameters," ZEEE
Stroke and aphasia quality-of-life scale-39: Reliability and validity of the Turkish version.
Noyan-ErbaŞ, AyŞin; Toğram, Bülent
2016-10-01
The aim of this study was to adapt the stroke and aphasia quality-of-life scale-39 (SAQoL-39) to the Turkish language and carry out a reliability and validity study of the instrument in a group of patients with aphasia. The study was a descriptive study and contained three phases: adaptation of the SAQoL-39 to the Turkish language, administration of the scale to 30 aphasia patients and reliability and validity studies of the scale. Internal consistency was assessed with Cronbach's alpha and test-re-test reliability was explored (n = 14). The adaptation process was completed based on inter-rater agreement on the translated items and within the scope of final editing by the authors of the study. The SAQoL-39 in Turkish exhibited high test-re-test reliability (ICC =0.97) as well as acceptability with minimal missing data (0-1.4). This instrument exhibited high internal consistency (Cronbach's α = 0.70-0.97), domain-total correlations (r = 0.76-0.85) and inter-domain correlations (r = 0.40-0.68). The analysis shows that the Turkish version of SAQoL-39 is a scale that is highly acceptable, valid and reliable and can be easily used in evaluating the quality-of-life of Turkish people with aphasia.
Factor VIII-associated antigen in human lymphatic endothelium.
Nagle, R B; Witte, M H; Martinez, A P; Witte, C L; Hendrix, M J; Way, D; Reed, K
1987-03-01
Lymphatic vascular endothelium both on tissue section and in culture exhibits positivity for Factor VIII-associated antigen although staining is generally less intense and more spotty than in comparable blood vascular endothelium. Lymphatic endothelium also exhibits Weibel-Palade bodies. Neither marker, therefore, reliably distinguishes blood vascular endothelium from lymphatic endothelium.
Steagall, Paulo V M; Monteiro, Beatriz P; Lavoie, Anne-Marie; Frank, Diane; Troncy, Eric; Luna, Stelio P L; Brondani, Juliana T
2017-01-01
Validation of the French version of the UNESP-Botucatu multidimensional composite pain scale for assessing postoperative pain in cats. The aim of this study was to validate the French version of the UNESP-Botucatu multidimensional composite pain scale (MCPS-Fr) to assess postoperative pain in cats. Two veterinarians and one DVM student identified three domains of behavior based on video analyses: "psychomotor change", "protection of the painful area" and "physiological variables". Internal consistency was excellent (Cronbach's alpha coefficient of 0.94, 0.90 and 0.61, respectively). Criterion validity was good to very good when evaluations from the three observers were compared with a "gold standard". Inter- and intra-rater reliability for each scale item were good to very good. The optimal cut-off point identified with a ROC curve was > 7 (scale range 0-30 points), with a sensitivity of 97.8% and specificity of 99.1%. The MCPS-Fr is a valid, reliable and responsive instrument for assessing acute pain in cats undergoing ovariohysterectomy.(Translated by Dr. Beatriz Monteiro).
López-Ortega, Mariana; Torres-Castro, Sara; Rosas-Carrasco, Oscar
2016-12-09
The Satisfaction with Life Scale (SWLS) has been widely used and has proven to be a valid and reliable instrument for assessing satisfaction with life in diverse population groups, however, research on satisfaction with life and validation of different measuring instruments in Mexican adults is still lacking. The objective was to evaluate the psychometric properties of the Satisfaction with Life Scale (SWLS) in a representative sample of Mexican adults. This is a methodological study to evaluate a satisfaction with life scale in a sample of 13,220 Mexican adults 50 years of age or older from the 2012 Mexican Health and Aging Study. The scale's reliability (internal consistency) was analysed using Cronbach's alpha and inter-item correlations. An exploratory factor analysis was also performed. Known-groups validity was evaluated comparing good-health and bad-health participants. Comorbidity, perceived financial situation, self-reported general health, depression symptoms, and social support were included to evaluate the validity between these measures and the total score of the scale using Spearman's correlations. The analysis of the scale's reliability showed good internal consistency (α = 0.74). The exploratory factor analysis confirmed the existence of a unique factor structure that explained 54% of the variance. SWLS was related to depression, perceived health, financial situation, and social support, and these relations were all statistically significant (P < .01). There was significant difference in life satisfaction between the good- and bad-health groups. Results show good internal consistency and construct validity of the SWLS. These results are comparable with results from previous studies. Meeting the study's objective to validate the scale, the results show that the Spanish version of the SWLS is a reliable and valid measure of satisfaction with life in the Mexican context.
Elson, D W; Jones, S; Caplan, N; Stewart, S; St Clair Gibson, A; Kader, D F
2011-12-01
Pain maps are used to determine the location of pain. Knee pain maps have previously been described, but only one study has reported on reliability and none report validity. The present study describes the generation of a photographic knee pain map (PKPM) together with its validity and reliability. A photographic representation of a pair of knees was chosen by 26 patients, (66.7%) from a group of 39. The selected photograph was modified and a template of anatomical zones was generated. The opinions of 25 independent subject matter experts were canvassed and validity ratios calculated for these zones, ranged from 0.28 to 0.84. Hypothetical comparisons were made between the PKPM and an alternative knee pain map, in a cross-sectional group of 26 patients (35 knees). Convergent patterns of validity were found where hypothesised. Reliability was determined using a different cohort of 44 patients (58 knees) who completed the PKPM before and after a sampling delay. Four of these patients were excluded with a short sampling delay. Calculated agreement of test-retest reproducibility was fair to good. All of the completed PKPM (151 knees) were then subject to further analysis where inter-rater reproducibility was good to very good and intra-rater reproducibility was very good. The PKPM is readily accessible to patients with low completion burden. It is both valid and reliable and we suggest it can be used in both clinical and research settings. Further studies are planned to explore its predictive ability as a diagnostic tool. The PKPM can be found at www.photographickneepainmap.com. Copyright © 2010 Elsevier B.V. All rights reserved.
Flosadottir, Vala; Roos, Ewa M; Ageberg, Eva
2017-09-01
The Activity Rating Scale (ARS) for disorders of the knee evaluates the level of activity by the frequency of participation in 4 separate activities with high demands on knee function, with a score ranging from 0 (none) to 16 (pivoting activities 4 times/wk). To translate and cross-culturally adapt the ARS into Swedish and to assess measurement properties of the Swedish version of the ARS. Cohort study (diagnosis); Level of evidence, 2. The COSMIN guidelines were followed. Participants (N = 100 [55 women]; mean age, 27 years) who were undergoing rehabilitation for a knee injury completed the ARS twice for test-retest reliability. The Knee injury and Osteoarthritis Outcome Score (KOOS), Tegner Activity Scale (TAS), and modernized Saltin-Grimby Physical Activity Level Scale (SGPALS) were administered at baseline to validate the ARS. Construct validity and responsiveness of the ARS were evaluated by testing predefined hypotheses regarding correlations between the ARS, KOOS, TAS, and SGPALS. The Cronbach alpha, intraclass correlation coefficients, absolute reliability, standard error of measurement, smallest detectable change, and Spearman rank-order correlation coefficients were calculated. The ARS showed good internal consistency (α ≈ 0.96), good test-retest reliability (intraclass correlation coefficient >0.9), and no systematic bias between measurements. The standard error of measurement was less than 2 points, and the smallest detectable change was less than 1 point at the group level and less than 5 points at the individual level. More than 75% of the hypotheses were confirmed, indicating good construct validity and good responsiveness of the ARS. The Swedish version of the ARS is valid, reliable, and responsive for evaluating the level of activity based on the frequency of participation in high-demand knee sports activities in young adults with a knee injury.
Clough-Gorr, Kerri M.; Rakowski, William; Clark, Melissa; Silliman, Rebecca A.
2009-01-01
Objective To develop and evaluate the psychometric properties of a measure of motivation and life outlook (Getting-Out-of-Bed [GoB]). Design Secondary analysis of baseline and 6-month data from a longitudinal follow-up study of older breast cancer survivors. Participants Women (N=660) diagnosed with primary breast cancer stage I -IIIA disease, age ≥65-years, and permission to contact from an attending physician in four geographic regions in the USA (city-based Los Angeles, California; state-wide in Minnesota, North Carolina, and Rhode Island). Measurement Data were collected over 6-months of follow-up from consenting patients’ medical records and telephone interviews with patients. Data collected included the 4-item GoB, health related quality of life (HRQoL), breast cancer, socio-demographic and health-related characteristics. Results Factor analysis produced, as hypothesized, one principal component with eigen values of 2.74baseline and 2.916-months which explained 68.6%baseline and 72.7%6-months of total variance. In further psychometric analyses, GoB exhibited good construct validity (divergent: low non-statistically significant correlations with unrelated constructs; convergent: moderate statistically significant correlations with related constructs; discriminant: distinguished high HRQoL groups with a high level of significance), excellent internal reliability (Cronbach’s alpha 0.84baseline,0.876-months), and produced stable measurements over 6-months. Women with GoB scores ≥50 at baseline were more likely at 6-months to have good HRQoL, good self-perceived health, and report regular exercise, indicating good predictive ability. Conclusion GoB demonstrated overall good psychometric properties in this sample of older breast cancer survivors, suggestive of a promising tool for assessing motivation and life outlook in older adults. Nevertheless, because it was developed and initially evaluated in a select sample, using measures with similar but not exact content overlap further evaluation is needed before it can be recommended for widespread use. PMID:19813135
The reliability and criterion validity of 2D video assessment of single leg squat and hop landing.
Herrington, Lee; Alenezi, Faisal; Alzhrani, Msaad; Alrayani, Hasan; Jones, Richard
2017-06-01
The objective was to assess the intra-tester, within and between day reliability of measurement of hip adduction (HADD) and frontal plane projection angles (FPPA) during single leg squat (SLS) and single leg landing (SLL) using 2D video and the validity of these measurements against those found during 3D motion capture. 15 healthy subjects had their SLS and SLL assessed using 3D motion capture and video analysis. Inter-tester reliability for both SLS and SLL when measuring FPPA and HADD show excellent correlations (ICC 2,1 0.97-0.99). Within and between day assessment of SLS and SLL showed good to excellent correlations for both variables (ICC 3,1 0.72-91). 2D FPPA measures were found to have good correlation with knee abduction angle in 3-D (r=0.79, p=0.008) during SLS, and also to knee abduction moment (r=0.65, p=0.009). 2D HADD showed very good correlation with 3D HADD during SLS (r=0.81, p=0.001), and a good correlation during SLL (r=0.62, p=0.013). All other associations were weak (r<0.4). This study suggests that 2D video kinematics have a reasonable association to what is being measured with 3D motion capture. Copyright © 2017 Elsevier Ltd. All rights reserved.
Raza, Meher; Ivry, Richard B.
2016-01-01
In standard taxonomies, motor skills are typically treated as representative of implicit or procedural memory. We examined two emblematic tasks of implicit motor learning, sensorimotor adaptation and sequence learning, asking whether individual differences in learning are correlated between these tasks, as well as how individual differences within each task are related to different performance variables. As a prerequisite, it was essential to establish the reliability of learning measures for each task. Participants were tested twice on a visuomotor adaptation task and on a sequence learning task, either the serial reaction time task or the alternating reaction time task. Learning was evident in all tasks at the group level and reliable at the individual level in visuomotor adaptation and the alternating reaction time task but not in the serial reaction time task. Performance variability was predictive of learning in both domains, yet the relationship was in the opposite direction for adaptation and sequence learning. For the former, faster learning was associated with lower variability, consistent with models of sensorimotor adaptation in which learning rates are sensitive to noise. For the latter, greater learning was associated with higher variability and slower reaction times, factors that may facilitate the spread of activation required to form predictive, sequential associations. Interestingly, learning measures of the different tasks were not correlated. Together, these results oppose a shared process for implicit learning in sensorimotor adaptation and sequence learning and provide insight into the factors that account for individual differences in learning within each task domain. NEW & NOTEWORTHY We investigated individual differences in the ability to implicitly learn motor skills. As a prerequisite, we assessed whether individual differences were reliable across test sessions. We found that two commonly used tasks of implicit learning, visuomotor adaptation and the alternating serial reaction time task, exhibited good test-retest reliability in measures of learning and performance. However, the learning measures did not correlate between the two tasks, arguing against a shared process for implicit motor learning. PMID:27832611
The development and validation of the Visual Analogue Self-Esteem Scale (VASES).
Brumfitt, S M; Sheeran, P
1999-11-01
To develop a visual analogue measure of self-esteem and test its psychometric properties. Two correlational studies involving samples of university students and aphasic speakers. Two hundred and forty-three university students completed multiple measures of self-esteem, depression and anxiety as well as measures of transitory mood and social desirability (Study 1). Two samples of aphasic speakers (N = 14 and N = 20) completed the Visual Analogue Self-Esteem Scale (VASES), the Rosenberg (1965) self-esteem scale and measures of depression and anxiety. (Study 2). Study 1 found evidence of good internal and test-retest reliability, construct validity and convergent and discriminant validity for a 10-item VASES. Study 2 demonstrated good internal reliability among aphasic speakers. The VASES is a short and easy to administer measure of self-esteem that possesses good psychometric properties.
Invited review: Animal-based indicators for on-farm welfare assessment for dairy goats.
Battini, M; Vieira, A; Barbieri, S; Ajuda, I; Stilwell, G; Mattiello, S
2014-11-01
This paper reviews animal-based welfare indicators to develop a valid, reliable, and feasible on-farm welfare assessment protocol for dairy goats. The indicators were considered in the light of the 4 accepted principles (good feeding, good housing, good health, appropriate behavior) subdivided into 12 criteria developed by the European Welfare Quality program. We will only examine the practical indicators to be used on-farm, excluding those requiring the use of specific instruments or laboratory analysis and those that are recorded at the slaughterhouse. Body condition score, hair coat condition, and queuing at the feed barrier or at the drinker seem the most promising indicators for the assessment of the "good feeding" principle. As to "good housing," some indicators were considered promising for assessing "comfort around resting" (e.g., resting in contact with a wall) or "thermal comfort" (e.g., panting score for the detection of heat stress and shivering score for the detection of cold stress). Several indicators related to "good health," such as lameness, claw overgrowth, presence of external abscesses, and hair coat condition, were identified. As to the "appropriate behavior" principle, different criteria have been identified: agonistic behavior is largely used as the "expression of social behavior" criterion, but it is often not feasible for on-farm assessment. Latency to first contact and the avoidance distance test can be used as criteria for assessing the quality of the human-animal relationship. Qualitative behavior assessment seems to be a promising indicator for addressing the "positive emotional state" criterion. Promising indicators were identified for most of the considered criteria; however, no valid indicator has been identified for "expression of other behaviors." Interobserver reliability has rarely been assessed and warrants further attention; in contrast, short-term intraobserver reliability is frequently assessed and some studies consider mid- and long-term reliability. The feasibility of most of the reviewed indicators in commercial farms still needs to be carefully evaluated, as several studies were performed under experimental conditions. Our review highlights some aspects of goat welfare that have been widely studied, but some indicators need to be investigated further and drafted before being included in a valid, reliable, and feasible welfare assessment protocol. The indicators selected and examined may be an invaluable starting point for the development of an on-farm welfare assessment protocol for dairy goats. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Wollin, Martin; Purdam, Craig; Drew, Michael K
2016-01-01
To investigate inter and intra-tester reliability of an externally fixed dynamometry unilateral hamstring strength test, in the elite sports setting. Reliability study. Sixteen, injury-free, elite male youth football players (age=16.81±0.54 years, height=180.22±5.29cm, weight 73.88±6.54kg, BMI=22.57±1.42) gave written informed consent. Unilateral maximum isometric peak hamstring force was evaluated by externally fixed dynamometry for inter-tester, intra-day and intra-tester, inter-week reliability. The test position was standardised to correlate with the terminal swing phase of the gait running cycle. Inter and intra-tester values demonstrated good to high levels of reliability. The intra-class coefficient (ICC) for inter-tester, intra-day reliability was 0.87 (95% CI=0.75-0.93) with standard error of measure percentage (SEM%) 4.7 and minimal detectable change percentage (MDC%) 12.9. Intra-tester, inter-week reliability results were ICC 0.86 (95% CI, 0.74-0.93), SEM% 5.0 and MDC% 14.0. This study demonstrates good to high inter and intra-tester reliability of isometric externally fixed dynamometry unilateral hamstring strength testing in the regular elite sport setting involving elite male youth football players. The intra-class coefficient in association with the low standard error of measure and minimal detectable change percentages suggest that this procedure is appropriate for clinical and academic use as well as monitoring hamstring strength in the elite sport setting. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.
Kenyon, Lisa K.; Elliott, James M; Cheng, M. Samuel
2016-01-01
Purpose/Background Despite the availability of various field-tests for many competitive sports, a reliable and valid test specifically developed for use in men's gymnastics has not yet been developed. The Men's Gymnastics Functional Measurement Tool (MGFMT) was designed to assess sport-specific physical abilities in male competitive gymnasts. The purpose of this study was to develop the MGFMT by establishing a scoring system for individual test items and to initiate the process of establishing test-retest reliability and construct validity. Methods A total of 83 competitive male gymnasts ages 7-18 underwent testing using the MGFMT. Thirty of these subjects underwent re-testing one week later in order to assess test-retest reliability. Construct validity was assessed using a simple regression analysis between total MGFMT scores and the gymnasts’ USA-Gymnastics competitive level to calculate the coefficient of determination (r2). Test-retest reliability was analyzed using Model 1 Intraclass correlation coefficients (ICC). Statistical significance was set at the p<0.05 level. Results The relationship between total MGFMT scores and subjects’ current USA-Gymnastics competitive level was found to be good (r2 = 0.63). Reliability testing of the MGFMT composite test score showed excellent test-retest reliability over a one-week period (ICC = 0.97). Test-retest reliability of the individual component tests ranged from good to excellent (ICC = 0.75-0.97). Conclusions The results of this study provide initial support for the construct validity and test-retest reliability of the MGFMT. Level of Evidence Level 3 PMID:27999723
A new approach to the measurement of pelvic asymmetry: proposed methods and reliability.
Gnat, Rafael; Biały, Maciej
2015-05-01
This is a methodological study presenting a novel method of pelvic asymmetry (PA) measurement for use in the research laboratory setting. The purpose of the study is (1) to establish intrarater and interrater reliability of the proposed measures of PA, (2) to verify the influence of repeated measurements on the reliability, and (3) to assess correlation between the proposed measures of PA. Twelve healthy volunteers participated, and 2 teams of raters were involved. Registration of anatomic landmarks' positions in the optical motion capture system was repeated 3 times. Two asymmetry indexes were calculated: for pelvic torsion and for lateral pelvic tilt. Interclass correlation coefficients (ICCs), standard errors of measurement, and smallest detectable differences were used to describe the intrarater and interrater reliability of the 2 indexes. After 2 repeated registrations of pelvic landmarks' positions, the reliability of our asymmetry indexes was good and excellent. The ICCs for intrarater reliability ranged from 0.96 to 0.97; the ICCs for interrater reliability ranged 0.81 to 0.90. There was moderate, nonsignificant correlation between asymmetry indexes for pelvis torsion and for lateral pelvic tilt (r = 0.45, P = .14). The 2 proposed asymmetry indexes showed good and excellent intrarater and interrater reliability after 2 repeated registrations of pelvic landmarks' positions and thus may be useful in the research laboratory setting. However, these indexes are not strongly correlated, which suggests that the 2 types of PA may constitute different clinical entities. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.
Young, Ian A; Dunning, James; Butts, Raymond; Cleland, Joshua A; Fernández-de-Las-Peñas, César
2018-01-01
Background Self-reported disability and pain intensity are commonly used outcomes in patients with cervicogenic headaches. However, there is a paucity of psychometric evidence to support the use of these self-report outcomes for individuals treated with cervicogenic headaches. Therefore, it is unknown if these measures are reliable, responsive, or result in meaningful clinically important changes in this patient population. Methods A secondary analysis of a randomized clinical trial (n = 110) examining the effects of spinal manipulative therapy with and without exercise in patients with cervicogenic headaches. Reliability, construct validity, responsiveness and thresholds for minimal detectable change and clinically important difference values were calculated for the Neck Disability Index and Numeric Pain Rating Scale. Results The Neck Disability Index exhibited excellent reliability (ICC = 0.92; [95 % CI: 0.46-0.97]), while the Numeric Pain Rating Scale exhibited moderate reliability (ICC = 0.72; [95 % CI: 0.08-0.90]) in the short term. Both instruments also exhibited adequate responsiveness (area under the curve; range = 0.78-0.93) and construct validity ( p < 0.001) in this headache population. Conclusions Both instruments seem well suited as short-term self-report measures for patients with cervicogenic headaches. Clinicians and researchers should expect at least a 2.5-point reduction on the numeric pain rating scale and a 5.5-point reduction on the neck disability index after 4 weeks of intervention to be considered clinically meaningful.
Yapali, Gökmen; Günel, Mintaze Kerem; Karahan, Sevilay
2012-05-15
The study design was cross-cultural adaptation and investigation of reliability and validity of the Copenhagen Neck Functional Disability Scale (CNFDS). The aim of this study was to translate the CNFDS into Turkish language and assess its reliability and validity among patients with neck pain in Turkish population. The CNFDS is a reliable and valid evaluation instrument for disability, but there is no published the Turkish version of the CNFDS. One hundred one subjects who had chronic neck pain were included in this study. The CNFDS, Neck Pain and Disability Scale, and visual analogue scale were administered to all subjects. For investigating test-retest reliability, correlation between CNFDS scores, applied at 1-week interval, intraclass correlation coefficient score for test-retest reliability was 0.86 (95% confidence interval = 0.679-0.935). There was no difference between test-retest scores (P < 0.001). For investigating concurrent validity, correlation between total score of the CNFDS and the mean visual analogue scale was r = 0.73 (P < 0.001). Concurrent validity of the CNFDS was very good. For investigating construct validity, correlation between total score of the CNFDS and the Neck Pain and Disability Scale was r = 0.78 (P < 0.001). Construct validity of the CNFDS was also very good. Our results suggest that the Turkish version of the CNFDS is a reliable and valid instrument for Turkish people.
Test-retest reliability of effective connectivity in the face perception network.
Frässle, Stefan; Paulus, Frieder Michel; Krach, Sören; Jansen, Andreas
2016-02-01
Computational approaches have great potential for moving neuroscience toward mechanistic models of the functional integration among brain regions. Dynamic causal modeling (DCM) offers a promising framework for inferring the effective connectivity among brain regions and thus unraveling the neural mechanisms of both normal cognitive function and psychiatric disorders. While the benefit of such approaches depends heavily on their reliability, systematic analyses of the within-subject stability are rare. Here, we present a thorough investigation of the test-retest reliability of an fMRI paradigm for DCM analysis dedicated to unraveling intra- and interhemispheric integration among the core regions of the face perception network. First, we examined the reliability of face-specific BOLD activity in 25 healthy volunteers, who performed a face perception paradigm in two separate sessions. We found good to excellent reliability of BOLD activity within the DCM-relevant regions. Second, we assessed the stability of effective connectivity among these regions by analyzing the reliability of Bayesian model selection and model parameter estimation in DCM. Reliability was excellent for the negative free energy and good for model parameter estimation, when restricting the analysis to parameters with substantial effect sizes. Third, even when the experiment was shortened, reliability of BOLD activity and DCM results dropped only slightly as a function of the length of the experiment. This suggests that the face perception paradigm presented here provides reliable estimates for both conventional activation and effective connectivity measures. We conclude this paper with an outlook on potential clinical applications of the paradigm for studying psychiatric disorders. Hum Brain Mapp 37:730-744, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Reliability of the Structured Clinical Interview for DSM-5 Sleep Disorders Module.
Taylor, Daniel J; Wilkerson, Allison K; Pruiksma, Kristi E; Williams, Jacob M; Ruggero, Camilo J; Hale, Willie; Mintz, Jim; Organek, Katherine Marczyk; Nicholson, Karin L; Litz, Brett T; Young-McCaughan, Stacey; Dondanville, Katherine A; Borah, Elisa V; Brundige, Antoinette; Peterson, Alan L
2018-03-15
To develop and demonstrate interrater reliability for a Structured Clinical Interview for Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) Sleep Disorders (SCISD). The SCISD was designed to be a brief, reliable, and valid interview assessment of adult sleep disorders as defined by the DSM-5. A sample of 106 postdeployment active-duty military members seeking cognitive behavioral therapy for insomnia in a randomized clinical trial were assessed with the SCISD prior to treatment to determine eligibility. Audio recordings of these interviews were double-scored for interrater reliability. The interview is 8 pages long, includes 20 to 51 questions, and takes 10 to 20 minutes to administer. Of the nine major disorders included in the SCISD, six had prevalence rates high enough (ie, n ≥ 5) to include in analyses. Cohen kappa coefficient (κ) was used to assess interrater reliability for insomnia, hypersomnolence, obstructive sleep apnea hypopnea (OSAH), circadian rhythm sleep-wake, nightmare, and restless legs syndrome disorders. There was excellent interrater reliability for insomnia (1.0) and restless legs syndrome (0.83); very good reliability for nightmare disorder (0.78) and OSAH (0.73); and good reliability for hypersomnolence (0.50) and circadian rhythm sleep-wake disorders (0.50). The SCISD is a brief, structured clinical interview that is easy for clinicians to learn and use. The SCISD showed moderate to excellent interrater reliability for six of the major sleep disorders in the DSM-5 among active duty military seeking cognitive behavioral therapy for insomnia in a randomized clinical trial. Replication and extension studies are needed. Registry: ClinicalTrials.gov; Title: Comparing Internet and In-Person Brief Cognitive Behavioral Therapy of Insomnia; Identifier: NCT01549899; URL: https://clinicaltrials.gov/ct2/show/NCT01549899. © 2018 American Academy of Sleep Medicine.
Ludwin, Artur; Ludwin, Inga; Kudla, Marek; Kottner, Jan
2015-09-01
To estimate the inter-rater/intrarater reliability of the European Society of Human Reproduction and Embryology/European Society for Gynaecological Endoscopy (ESHRE-ESGE) classification of congenital uterine malformations and to compare the results obtained with the reliability of the American Society for Reproductive Medicine (ASRM) classification supplemented with additional morphometric criteria. Reliability/agreement study. Private clinic. Uterine malformations (n = 50 patients, consecutively included) and normal uterus (n = 62 women, randomly selected) constituted the study. These were classified based on real-time three-dimensional ultrasound single volume transvaginal (or transrectal in the case of virgins, 4 cases) ultrasonography findings, which were assessed by an expert rater based on the ESHRE-ESGE criteria. The samples were obtained from women of reproductive age. Unprocessed three-dimensional datasets were independently evaluated offline by two experienced, blinded raters using both classification systems. The κ-values and proportions of agreement. Standardized interpretation indicated that the ESHRE-ESGE system has substantial/good or almost perfect/very good reliability (κ >0.60 and >0.80), but the interpretation of the clinically relevant cutoffs of κ-values showed insufficient reliability for clinical use (κ < 0.90), especially in the diagnosis of septate uterus. The ASRM system had sufficient reliability (κ > 0.95). The low reliability of the ESHRE-ESGE system may lead to a lack of consensus about the management of common uterine malformations and biased research interpretations. The use of the ASRM classification, supplemented with simple morphometric criteria, may be preferred if their sufficient reliability can be confirmed real-time in a large sample size. Copyright © 2015 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Lenzlinger-Asprion, Rahel; Keller, Niculina; Meichtry, André; Luomajoki, Hannu
2017-01-31
Hip joint complaints are a problem associated with increasing age and impair the mobility of a large section of the elderly population. Reliable and valid tests are necessary for a thorough investigation of a joint. A fundamental function of the hip joint is movement control and a test of this function forms a part of the standard examination. Until now there have been few scientific studies which specifically investigate the reliability of measurement tests of movement control of the hip joint. The aim of this study was to examine the intratester and intertester reliability of the movement control tests of the hip joint which are in use in current clinical practice. Sixteen participants with hip joint complaints and 14 without hip joint impairment were recruited. All participants performed five active movement control tests for the hip joint and were video filmed whilst performing these tests. These films formed the basis for the evaluation and were assessed by two independent physiotherapists. For the intertester and intratester reliability calculations specially set weighted kappa values and the calculated percentages were used. The intertester reliability of the five examined movement control tests of the hip joint showed good to almost perfect values (weighted kappa (wk) = 0.56-0.87). The intratester reliability of the more experienced evaluator A was better in regards to the less experienced evaluator B (average wk = 0.62 vs 0.38). The visual evaluation of movement control tests of the hip joint is especially reliable when carried out by an experienced evaluator. 4 out of 5 tests also showed good results for intertester reliability and support their use in clinical practice.
Fan, Ching-Lin; Shang, Ming-Chi; Li, Bo-Jyun; Lin, Yu-Zuo; Wang, Shea-Jue; Lee, Win-Der; Hung, Bohr-Ran
2015-04-13
This study proposes a two-photomask process for fabricating amorphous indium-gallium-zinc oxide (a-IGZO) thin-film transistors (TFTs) that exhibit a self-aligned structure. The fabricated TFTs, which lack etching-stop (ES) layers, have undamaged a-IGZO active layers that facilitate superior performance. In addition, we demonstrate a bilayer passivation method that uses a polytetrafluoroethylene (Teflon) and SiO₂ combination layer for improving the electrical reliability of the fabricated TFTs. Teflon was deposited as a buffer layer through thermal evaporation. The Teflon layer exhibited favorable compatibility with the underlying IGZO channel layer and effectively protected the a-IGZO TFTs from plasma damage during SiO₂ deposition, resulting in a negligible initial performance drop in the a-IGZO TFTs. Compared with passivation-free a-IGZO TFTs, passivated TFTs exhibited superior stability even after 168 h of aging under ambient air at 95% relative humidity.
Reliability of physical functioning tests in patients with low back pain: a systematic review.
Denteneer, Lenie; Van Daele, Ulrike; Truijen, Steven; De Hertogh, Willem; Meirte, Jill; Stassijns, Gaetane
2018-01-01
The aim of this study was to provide a comprehensive overview of physical functioning tests in patients with low back pain (LBP) and to investigate their reliability. A systematic computerized search was finalized in four different databases on June 24, 2017: PubMed, Web of Science, Embase, and MEDLINE. Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines were followed during all stages of this review. Clinical studies that investigate the reliability of physical functioning tests in patients with LBP were eligible. The methodological quality of the included studies was assessed with the use of the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) checklist. To come to final conclusions on the reliability of the identified clinical tests, the current review assessed three factors, namely, outcome assessment, methodological quality, and consistency of description. A total of 20 studies were found eligible and 38 clinical tests were identified. Good overall test-retest reliability was concluded for the extensor endurance test (intraclass correlation coefficient [ICC]=0.93-0.97), the flexor endurance test (ICC=0.90-0.97), the 5-minute walking test (ICC=0.89-0.99), the 50-ft walking test (ICC=0.76-0.96), the shuttle walk test (ICC=0.92-0.99), the sit-to-stand test (ICC=0.91-0.99), and the loaded forward reach test (ICC=0.74-0.98). For inter-rater reliability, only one test, namely, the Biering-Sörensen test (ICC=0.88-0.99), could be concluded to have an overall good inter-rater reliability. None of the identified clinical tests could be concluded to have a good intrarater reliability. Further investigation should focus on a better overall study methodology and the use of identical protocols for the description of clinical tests. The assessment of reliability is only a first step in the recommendation process for the use of clinical tests. In future research, the identified clinical tests in the current review should be further investigated for validity. Only when these clinimetric properties of a clinical test have been thoroughly investigated can a final conclusion regarding the clinical and scientific use of the identified tests be made. Copyright © 2017 Elsevier Inc. All rights reserved.
Hamre, Charlotta; Botolfsen, Pernille; Tangen, Gro Gujord; Helbostad, Jorunn L
2017-04-20
The Balance Evaluation Systems Test (BESTest) was developed to assess underlying systems for balance control in order to be able to individually tailor rehabilitation interventions to people with balance disorders. A short form, the Mini-BESTest, was developed as a screening test. The study aimed to assess interrater and test-retest reliability of the Norwegian version of the BESTest and the Mini-BESTest in community-dwelling people with increased risk of falling and to assess concurrent validity with the Fall Efficacy Scale-International (FES-I), and it was an observational study with a cross-sectional design. Forty-two persons with increased risk of falling (elderly over 65 years of age, persons with a history of stroke or Multiple Sclerosis) were assessed twice by two raters. Relative reliability was analysed with Intraclass Correlation Coefficient (ICC), and absolute reliability with standard error of measurement (SEM) and smallest detectable change (SDC). Concurrent validity was assessed against the FES-I using Spearman's rho. The BESTest showed very good interrater reliability (ICC = 0.98, SEM = 1.79, SDC 95 = 5.0) and test-retest reliability (rater A/rater B = ICC = 0.89/0.89, SEM = 3.9/4.3, SDC 95 = 10.8/11.8). The Mini-BESTest also showed very good interrater reliability (ICC = 0.95, SEM = 1.19, SDC 95 = 3.3) and test-retest reliability (rater A/rater B = ICC = 0.85/0.84, SEM = 1.8/1.9, SDC 95 = 4.9/5.2). The correlations were moderate between the FES-I and both the BESTest and the Mini-BESTest (Spearman's rho -0.51 and-0.50, p < 0.01). The BESTest and its short form, the Mini-BESTest, showed very good interrater and test-retest reliability when assessed in a heterogeneous sample of people with increased risk of falling. The concurrent validity measured against the FES-I showed moderate correlation. The results are comparable with earlier studies and indicate that the Norwegian versions can be used in daily clinic and in research.
Yeh, W B; Tseng, M J; Chang, N T; Wu, S Y; Tsai, Y S
2014-10-01
While morphological identification of thrips species has been difficult because of their minute size and a lack of easily recognizable characteristics, molecular identification based on the development of specific molecular markers can be easily and reliably carried out. Among the known molecular markers, the nuclear internal transcribed spacer (ITS) exhibits distinguishable variations among thrips species. In this study, sequences of ITS2 region of 10 agriculturally important thrips were established to design species-specific primers for polymerase chain reaction (PCR). ITS2 sequence variations within these species were far less than those among species, indicating the suitability of this marker for species-specific primers design. These primers, though with one or two sporadically variable positions, showed a good efficacy within species. The specificity of these primers, examined on thrips species belonging to 15 genera, proved satisfactory. Furthermore, a multiplex PCR was used successfully for identifying Frankliniella occidentalis (Pergande), an insect pest monitored for quarantine purpose, and three additional thrips also commonly found in imported agricultural products and field samples, i.e., Thrips tabaci Lindeman, Thrips hawaiiensis (Morgan), and Frankliniella intonsa (Trybom). This study has demonstrated that specific primers and multiplex PCR based on ITS2 are reliable, convenient, and diagnostic tool to discriminate thrips species of quarantine and agricultural importance. © 2014 Entomological Society of America.
Wan, Hao; Yin, Heyu; Mason, Andrew J.
2016-01-01
Intense study on gas sensors has been conducted to implement fast gas sensing with high sensitivity, reliability and long lifetime. This paper presents a rapid amperometric method for gas sensing based on a room temperature ionic liquid electrochemical gas sensor. To implement a miniaturized sensor with a fast response time, a three electrode system with gold interdigitated electrodes was fabricated by photolithography on a porous polytetrafluoroethylene substrate that greatly enhances gas diffusion. Furthermore, based on the reversible reaction of oxygen, a new transient double potential amperometry (DPA) was explored for electrochemical analysis to decrease the measurement time and reverse reaction by-products that could cause current drift. Parameters in transient DPA including oxidation potential, oxidation period, reduction period and sample point were investigated to study their influence on the performance of the sensor. Oxygen measurement could be accomplished in 4 s, and the sensor presented a sensitivity of 0.2863 μA/[%O2] and a linearity of 0.9943 when tested in air samples with different oxygen concentrations. Repeatability and long-term stability were also investigated, and the sensor was shown to exhibit good reliability. In comparison to conventional constant potential amperometry, transient DPA was shown to reduce relative standard deviation by 63.2%. With transient DPA, the sensitivity, linearity, repeatability, measurement time and current drift characteristics demonstrated by the presented gas sensor are promising for acute exposure applications. PMID:28603384
King, Andy J; Jensen, Jakob D; Davis, LaShara A; Carcioppolo, Nick
2014-01-01
There is a paucity of research on the visual images used in health communication messages and campaign materials. Even though many studies suggest further investigation of these visual messages and their features, few studies provide specific constructs or assessment tools for evaluating the characteristics of visual messages in health communication contexts. The authors conducted 2 studies to validate a measure of perceived visual informativeness (PVI), a message construct assessing visual messages presenting statistical or indexical information. In Study 1, a 7-item scale was created that demonstrated good internal reliability (α = .91), as well as convergent and divergent validity with related message constructs such as perceived message quality, perceived informativeness, and perceived attractiveness. PVI also converged with a preference for visual learning but was unrelated to a person's actual vision ability. In addition, PVI exhibited concurrent validity with a number of important constructs including perceived message effectiveness, decisional satisfaction, and three key public health theory behavior predictors: perceived benefits, perceived barriers, and self-efficacy. Study 2 provided more evidence that PVI is an internally reliable measure and demonstrates that PVI is a modifiable message feature that can be tested in future experimental work. PVI provides an initial step to assist in the evaluation and testing of visual messages in campaign and intervention materials promoting informed decision making and behavior change.
A Flexible Stretchable Hydrogel Electrolyte for Healable All-in-One Configured Supercapacitors.
Guo, Ying; Zheng, Kaiqiang; Wan, Pengbo
2018-04-01
The development of integrated high-performance supercapacitors with all-in-one configuration, excellent flexibility and autonomously intrinsic self-healability, and without the extra healable film layers, is still tremendously challenging. Compared to the sandwich-like laminated structures of supercapacitors with augmented interfacial contact resistance, the flexible healable integrated supercapacitor with all-in-one structure could theoretically improve their interfacial contact resistance and energy densities, simplify the tedious device assembly process, prolong the lifetime, and avoid the displacement and delamination of multilayered configurations under deformations. Herein, a flexible healable all-in-one configured supercapacitor with excellent flexibility and reliable self-healing ability by avoiding the extra healable film substrates and the postassembled sandwich-like laminated structures is developed. The healable all-in-one configured supercapacitor is prepared from in situ polymerization and deposition of nanocomposites electrode materials onto the two-sided faces of the self-healing hydrogel electrolyte separator. The self-healing hydrogel film is obtained from the physically crosslinked hydrogel with enormous hydrogen bonds, which can endow the healable capability through dynamic hydrogen bonding. The assembled all-in-one configured supercapacitor exhibits enhanced capacitive performance, good cycling stability, reliable self-healing capability, and excellent flexibility. It holds broad prospects for obtaining various flexible healable all-in-one configured supercapacitors for working as portable energy storage devices in wearable electronics. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wan, Hao; Yin, Heyu; Mason, Andrew J
2017-04-01
Intense study on gas sensors has been conducted to implement fast gas sensing with high sensitivity, reliability and long lifetime. This paper presents a rapid amperometric method for gas sensing based on a room temperature ionic liquid electrochemical gas sensor. To implement a miniaturized sensor with a fast response time, a three electrode system with gold interdigitated electrodes was fabricated by photolithography on a porous polytetrafluoroethylene substrate that greatly enhances gas diffusion. Furthermore, based on the reversible reaction of oxygen, a new transient double potential amperometry (DPA) was explored for electrochemical analysis to decrease the measurement time and reverse reaction by-products that could cause current drift. Parameters in transient DPA including oxidation potential, oxidation period, reduction period and sample point were investigated to study their influence on the performance of the sensor. Oxygen measurement could be accomplished in 4 s, and the sensor presented a sensitivity of 0.2863 μA/[%O 2 ] and a linearity of 0.9943 when tested in air samples with different oxygen concentrations. Repeatability and long-term stability were also investigated, and the sensor was shown to exhibit good reliability. In comparison to conventional constant potential amperometry, transient DPA was shown to reduce relative standard deviation by 63.2%. With transient DPA, the sensitivity, linearity, repeatability, measurement time and current drift characteristics demonstrated by the presented gas sensor are promising for acute exposure applications.
Least Reliable Bits Coding (LRBC) for high data rate satellite communications
NASA Technical Reports Server (NTRS)
Vanderaar, Mark; Wagner, Paul; Budinger, James
1992-01-01
An analysis and discussion of a bandwidth efficient multi-level/multi-stage block coded modulation technique called Least Reliable Bits Coding (LRBC) is presented. LRBC uses simple multi-level component codes that provide increased error protection on increasingly unreliable modulated bits in order to maintain an overall high code rate that increases spectral efficiency. Further, soft-decision multi-stage decoding is used to make decisions on unprotected bits through corrections made on more protected bits. Using analytical expressions and tight performance bounds it is shown that LRBC can achieve increased spectral efficiency and maintain equivalent or better power efficiency compared to that of Binary Phase Shift Keying (BPSK). Bit error rates (BER) vs. channel bit energy with Additive White Gaussian Noise (AWGN) are given for a set of LRB Reed-Solomon (RS) encoded 8PSK modulation formats with an ensemble rate of 8/9. All formats exhibit a spectral efficiency of 2.67 = (log2(8))(8/9) information bps/Hz. Bit by bit coded and uncoded error probabilities with soft-decision information are determined. These are traded with with code rate to determine parameters that achieve good performance. The relative simplicity of Galois field algebra vs. the Viterbi algorithm and the availability of high speed commercial Very Large Scale Integration (VLSI) for block codes indicates that LRBC using block codes is a desirable method for high data rate implementations.
Better Minds, Better Morals: A Procedural Guide to Better Judgment.
Schaefer, G Owen; Savulescu, Julian
2017-01-01
Making more moral decisions - an uncontroversial goal, if ever there was one. But how to go about it? In this article, we offer a practical guide on ways to promote good judgment in our personal and professional lives. We will do this not by outlining what the good life consists in or which values we should accept.Rather, we offer a theory of procedural reliability : a set of dimensions of thought that are generally conducive to good moral reasoning. At the end of the day, we all have to decide for ourselves what is good and bad, right and wrong. The best way to ensure we make the right choices is to ensure the procedures we're employing are sound and reliable. We identify four broad categories of judgment to be targeted - cognitive, self-management, motivational and interpersonal. Specific factors within each category are further delineated, with a total of 14 factors to be discussed. For each, we will go through the reasons it generally leads to more morally reliable decision-making, how various thinkers have historically addressed the topic, and the insights of recent research that can offer new ways to promote good reasoning. The result is a wide-ranging survey that contains practical advice on how to make better choices. Finally, we relate this to the project of transhumanism and prudential decision-making. We argue that transhumans will employ better moral procedures like these. We also argue that the same virtues will enable us to take better control of our own lives, enhancing our responsibility and enabling us to lead better lives from the prudential perspective.
GABA and primary motor cortex inhibition in young and older adults: a multimodal reliability study.
Mooney, Ronan A; Cirillo, John; Byblow, Winston D
2017-07-01
The effects of healthy aging on γ-aminobutyric acid (GABA) within primary motor cortex (M1) remain poorly understood. Studies have reported contrasting results, potentially due to limitations with the common assessment technique. The aim of the present study was to investigate the effect of healthy aging on M1 GABA concentration and neurotransmission using a multimodal approach. Fifteen young and sixteen older adults participated in this study. Magnetic resonance spectroscopy (MRS) was used to measure M1 GABA concentration. Single-pulse and threshold-tracking paired-pulse transcranial magnetic stimulation (TMS) protocols were used to examine cortical silent period duration, short- and long-interval intracortical inhibition (SICI and LICI), and late cortical disinhibition (LCD). The reliability of TMS measures was examined with intraclass correlation coefficient analyses. SICI at 1 ms was reduced in older adults (15.13 ± 2.59%) compared with young (25.66 ± 1.44%; P = 0.002). However, there was no age-related effect for cortical silent period duration, SICI at 3 ms, LICI, or LCD (all P > 0.66). The intersession reliability of threshold-tracking measures was good to excellent for both young (range 0.75-0.96) and older adults (range 0.88-0.93). Our findings indicate that extrasynaptic inhibition may be reduced with advancing age, whereas GABA concentration and synaptic inhibition are maintained. Furthermore, MRS and threshold-tracking TMS provide valid and reliable assessment of M1 GABA concentration and neurotransmission, respectively, in young and older adults. NEW & NOTEWORTHY γ-Aminobutyric acid (GABA) in primary motor cortex was assessed in young and older adults using magnetic resonance spectroscopy and threshold-tracking paired-pulse transcranial magnetic stimulation. Older adults exhibited reduced extrasynaptic inhibition (short-interval intracortical inhibition at 1 ms) compared with young, whereas GABA concentration and synaptic inhibition were similar between age groups. We demonstrate that magnetic resonance spectroscopy and threshold-tracking provide valid and reliable assessments of primary motor cortex GABA concentration and neurotransmission, respectively. Copyright © 2017 the American Physiological Society.
Validation of the korean-version of the nonmotor symptoms scale for Parkinson's disease.
Koh, Seong-Beom; Kim, Jae Woo; Ma, Hyeo-Il; Ahn, Tae-Beom; Cho, Jin Whan; Lee, Phil Hyu; Chung, Sun Ju; Kim, Joong-Seok; Kwon, Do Young; Baik, Jong Sam
2012-12-01
Non-motor symptoms are common in Parkinson's disease (PD), and are the primary cause of disability in many PD patients. Our aim in this study was to translate the origin non-motor symptoms scale for PD (NMSS), which was written in English, into Korean (K-NMSS), and to evaluate its reliability and validity for use with Korean-speaking patients with PD. In total, 102 patients with PD from 9 movement disorders sections of university teaching hospitals in Korea were enrolled in this study. They were assessed using the K-NMSS, the Unified Parkinson's Disease Rating Scale (UPDRS), the Korean version of the Mini-Mental Status Examination (K-MMSE), the Korean version of the Montgomery-Asberg Depression Rating Scale (K-MADS), the Epworth Sleepiness Scale (ESS), and Parkinson's Disease Questionnaire 39 (PDQ39). Test-retest reliability was assessed over a time interval of 10-14 days in all but one patient. The K-NMSS was administered to 102 patients with PD. The internal consistency and reliability of this tool was 0.742 (mean Cronbach's α-coefficient). The test-retest correlation reliability was 0.941 (Guttman split-half coefficient). There was a moderate correlation between the total K-NMSS score and the scores for UPDRS part I [Spearman's rank correlation coefficient, (rS)=0.521, p<0.001] and UPDRS part II (rS=0.464, p=0.001), but there was only a weak correlation between the total K-NMSS score and the UPDRS part III score (rS=0.288, p=0.003). The total K-NMSS score was significantly correlated with the K-MADS (rS=0.594, p<0.001), K-MMSE (rS=-0.291, p=0.003), and ESS (rS=0.348, p<0.001). The total K-NMSS score was also significantly and positively correlated with the PDQ39 score (rS=0.814, p<0.001). The K-NMSS exhibited good reliability and validity for the assessment of non-motor symptoms in Korean PD patients.
Validation of the Korean-Version of the Nonmotor Symptoms Scale for Parkinson's Disease
Koh, Seong-Beom; Kim, Jae Woo; Ma, Hyeo-Il; Ahn, Tae-Beom; Cho, Jin Whan; Lee, Phil Hyu; Chung, Sun Ju; Kim, Joong-Seok; Kwon, Do Young
2012-01-01
Background and Purpose Non-motor symptoms are common in Parkinson's disease (PD), and are the primary cause of disability in many PD patients. Our aim in this study was to translate the origin non-motor symptoms scale for PD (NMSS), which was written in English, into Korean (K-NMSS), and to evaluate its reliability and validity for use with Korean-speaking patients with PD. Methods In total, 102 patients with PD from 9 movement disorders sections of university teaching hospitals in Korea were enrolled in this study. They were assessed using the K-NMSS, the Unified Parkinson's Disease Rating Scale (UPDRS), the Korean version of the Mini-Mental Status Examination (K-MMSE), the Korean version of the Montgomery-Asberg Depression Rating Scale (K-MADS), the Epworth Sleepiness Scale (ESS), and Parkinson's Disease Questionnaire 39 (PDQ39). Test-retest reliability was assessed over a time interval of 10-14 days in all but one patient. Results The K-NMSS was administered to 102 patients with PD. The internal consistency and reliability of this tool was 0.742 (mean Cronbach's α-coefficient). The test-retest correlation reliability was 0.941 (Guttman split-half coefficient). There was a moderate correlation between the total K-NMSS score and the scores for UPDRS part I [Spearman's rank correlation coefficient, (rS)=0.521, p<0.001] and UPDRS part II (rS=0.464, p=0.001), but there was only a weak correlation between the total K-NMSS score and the UPDRS part III score (rS=0.288, p=0.003). The total K-NMSS score was significantly correlated with the K-MADS (rS=0.594, p<0.001), K-MMSE (rS=-0.291, p=0.003), and ESS (rS=0.348, p<0.001). The total K-NMSS score was also significantly and positively correlated with the PDQ39 score (rS=0.814, p<0.001). Conclusions The K-NMSS exhibited good reliability and validity for the assessment of non-motor symptoms in Korean PD patients. PMID:23323136
Chen, Chia-Wei; Chu, Hsin; Tsai, Chia-Fen; Yang, Hui-Ling; Tsai, Jui-Chen; Chung, Min-Huey; Liao, Yuan-Mei; Chi, Mei-Ju; Chou, Kuei-Ru
2015-11-01
The purpose of this study was to translate the Rowland Universal Dementia Assessment Scale into Chinese and to evaluate the psychometric properties (reliability and validity) and the diagnostic properties (sensitivity, specificity and predictive values) of the Chinese version of the Rowland Universal Dementia Assessment Scale. The accurate detection of early dementia requires screening tools with favourable cross-cultural linguistic and appropriate sensitivity, specificity, and predictive values, particularly for Chinese-speaking populations. This was a cross-sectional, descriptive study. Overall, 130 participants suspected to have cognitive impairment were enrolled in the study. A test-retest for determining reliability was scheduled four weeks after the initial test. Content validity was determined by five experts, whereas construct validity was established by using contrasted group technique. The participants' clinical diagnoses were used as the standard in calculating the sensitivity, specificity, positive predictive value and negative predictive value. The study revealed that the Chinese version of the Rowland Universal Dementia Assessment Scale exhibited a test-retest reliability of 0.90, an internal consistency reliability of 0.71, an inter-rater reliability (kappa value) of 0.88 and a content validity index of 0.97. Both the patients and healthy contrast group exhibited significant differences in their cognitive ability. The optimal cut-off points for the Chinese version of the Rowland Universal Dementia Assessment Scale in the test for mild cognitive impairment and dementia were 24 and 22, respectively; moreover, for these two conditions, the sensitivities of the scale were 0.79 and 0.76, the specificities were 0.91 and 0.81, the areas under the curve were 0.85 and 0.78, the positive predictive values were 0.99 and 0.83 and the negative predictive values were 0.96 and 0.91 respectively. The Chinese version of the Rowland Universal Dementia Assessment Scale exhibited sound reliability, validity, sensitivity, specificity and predictive values. This scale can help clinical staff members to quickly and accurately diagnose cognitive impairment and provide appropriate treatment as early as possible. © 2015 John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason, R.; Buxton, Roxanne E.; Lawrence, Emily L.; Sinka, Joseph; Guilliams, Mark E.; Ploutz-Snyder, Lori L.; Bloomberg, Jacob J.
2010-01-01
Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National
Salyers, M P; McHugo, G J; Cook, J A; Razzano, L A; Drake, R E; Mueser, K T
2001-09-01
Reliability of well-known instruments was examined in 202 people with severe mental illness participating in a multisite vocational study. We examined interrater reliability of the Positive and Negative Syndrome Scale (PANSS) and the internal consistency and test-retest reliability of the PANSS, the Rosenberg Self-Esteem Scale, the Medical Outcomes Study Short Form-36 (SF-36), and the Quality of Life Interview. Most scales had good levels of reliability, with intraclass correlation coefficients (ICCs) and coefficient alphas above .70. However, the SF-36 scales were generally less stable over time, particularly Social Functioning (ICC = .55). Test-retest reliability was lower among less educated respondents and among ethnic minorities. We recommend close monitoring of psychometric issues in future multisite studies.
Intrarater Reliability and Other Psychometrics of the Health Promoting Activities Scale (HPAS).
Muskett, Rachel; Bourke-Taylor, Helen; Hewitt, Alana
The Health Promoting Activities Scale (HPAS) measures the self-rated frequency with which adults participate in activities that promote health. We evaluated the internal consistency, construct validity, and intrarater reliability of the HPAS with a cohort of mothers (N = 56) of school-age children. We used an online survey that included the HPAS and measures of mental and physical health. Statistical analysis included intraclass correlation coefficients (ICCs), measurement error, error range, limits of agreement, and minimum detectable change (MDC). The HPAS showed good internal consistency (Cronbach's α = .73). Construct validity was supported by a significant difference in HPAS scores among participants grouped by physical activity level; no other differences were significant. Results included a high aggregate ICC of .90 and an MDC of 5 points. Our evaluation of the HPAS revealed good reliability and stability, suggesting suitability for ongoing evaluation as an outcome measure. Copyright © 2017 by the American Occupational Therapy Association, Inc.
Reliability and validity of the Parenting Scale of Inconsistency.
Yoshizumi, Takahiro; Murase, Satomi; Murakami, Takashi; Takai, Jiro
2006-08-01
The purposes of the present study were to develop a Parenting Scale of Inconsistency and to evaluate its initial reliability and validity. The 12 items assess the inconsistency among parents' moods, behaviors, and attitudes toward children. In the primary study, 517 participants completed three measures: the new Parenting Scale of Inconsistency, the Parental Bonding Instrument, and the Depression Scale of the General Health Questionnaire. The Parenting Scale of Inconsistency had good test-retest reliability of .85 and internal consistency of .88 (Cronbach coefficient alpha). Construct validity was good as Inconsistency scores were significantly correlated with the Care and Overprotection scores of the Parental Bonding Instrument and with the Depression scores. Moreover, Inconsistency scores' relation with a dimension of parenting style distinct from Care and Overprotection suggested that the Parenting Scale of Inconsistency had factorial validity. This scale seems a potential measure for examining the relationships between inconsistent parenting and the mental health of children.
The reliability of the Adelaide in-shoe foot model.
Bishop, Chris; Hillier, Susan; Thewlis, Dominic
2017-07-01
Understanding the biomechanics of the foot is essential for many areas of research and clinical practice such as orthotic interventions and footwear development. Despite the widespread attention paid to the biomechanics of the foot during gait, what largely remains unknown is how the foot moves inside the shoe. This study investigated the reliability of the Adelaide In-Shoe Foot Model, which was designed to quantify in-shoe foot kinematics and kinetics during walking. Intra-rater reliability was assessed in 30 participants over five walking trials whilst wearing shoes during two data collection sessions, separated by one week. Sufficient reliability for use was interpreted as a coefficient of multiple correlation and intra-class correlation coefficient of >0.61. Inter-rater reliability was investigated separately in a second sample of 10 adults by two researchers with experience in applying markers for the purpose of motion analysis. The results indicated good consistency in waveform estimation for most kinematic and kinetic data, as well as good inter-and intra-rater reliability. The exception is the peak medial ground reaction force, the minimum abduction angle and the peak abduction/adduction external hindfoot joint moments which resulted in less than acceptable repeatability. Based on our results, the Adelaide in-shoe foot model can be used with confidence for 24 commonly measured biomechanical variables during shod walking. Copyright © 2017 Elsevier B.V. All rights reserved.
Barzegar-Bafrooei, Ebrahim; Bakhtiary, Jalal; Khatoonabadi, Ahmad Reza; Fatehi, Farzad; Maroufizadeh, Saman; Fathali, Mojtaba
2016-01-01
Background: Dysphagia as a common condition affecting many aspects of the patient’s life. The Dysphagia Handicap Index (DHI) is a reliable self-reported questionnaire developed specifically to measure the impact of dysphagia on the patient’s quality of life. The aim of this study was to translate the questionnaire to Persian and to measure its validity and reliability in patients with neurogenic oropharyngeal dysphagia. Methods: A formal forward-backward translation of DHI was performed based on the guidelines for the cross-cultural adaptation of self-report measures. A total of 57 patients with neurogenic dysphagia who were referred to the neurology clinics of Tehran University of Medical Sciences, Iran, participated in this study. Internal consistency reliability of the DHI was examined using Cronbach’s alpha, and test-retest reliability of the scale was evaluated using intraclass correlation coefficient (ICC). Results: The internal consistency of the Persian DHI (P-DHI) was considered to be good; Cronbach’s alpha coefficient for the total P-DHI was 0.88. The test-retest reliability for the total and three subscales of the P-DHI ranged from 0.95 to 0.98 using ICC. Conclusion: The P-DHI demonstrated a good reliability, and it can be a valid instrument for evaluating the dysphagia effects on quality of life among Persian language population. PMID:27648173
Baur, Heiner; Groppa, Alessia Severina; Limacher, Regula; Radlinger, Lorenz
2016-02-02
Maximum strength and rate of force development (RFD) are 2 important strength characteristics for everyday tasks and athletic performance. Measurements of both parameters must be reliable. Expensive isokinetic devices with isometric modes are often used. The possibility of cost-effective measurements in a practical setting would facilitate quality control. The purpose of this study was to assess the reliability of measurements of maximum isometric strength (Fmax) and RFD on a conventional leg press. Sixteen subjects (23 ± 2 y, 1.68 ± 0.05 m, 59 ± 5 kg) were tested twice within 1 session. After warm-up, subjects performed 2 times 5 trials eliciting maximum voluntary isometric contractions on an instrumented leg press (1- and 2-legged randomized). Fmax (N) and RFD (N/s) were extracted from force-time curves. Reliability was determined for Fmax and RFD by calculating the intraclass correlation coefficient (ICC), the test-retest variability (TRV), and the bias and limits of agreement. Reliability measures revealed good to excellent ICCs of .80-.93. TRV showed mean differences between measurement sessions of 0.4-6.9%. The systematic error was low compared with the absolute mean values (Fmax 5-6%, RFD 1-4%). The implementation of a force transducer into a conventional leg press provides a viable procedure to assess Fmax and RFD. Both performance parameters can be assessed with good to excellent reliability allowing quality control of interventions.
Li, Hong-Yan; Bi, Rui-Xue; Zhong, Qing-Ling
2017-12-01
Disaster nurse education has received increasing importance in China. Knowing the abilities of disaster response in undergraduate nursing students is beneficial to promote teaching and learning. However, there are few valid and reliable tools that measure the abilities of disaster response in undergraduate nursing students. To develop a self-report scale of self-efficacy in disaster response for Chinese undergraduate nursing students and test its psychometric properties. Nursing students (N=318) from two medical colleges were chosen by purposive sampling. The Disaster Response Self-Efficacy Scale (DRSES) was developed and psychometrically tested. Reliability and content validity were studied. Construct validity was tested by exploratory and confirmatory factor analysis. Reliability was tested by internal consistency and test-retest reliability. The DRSES consisted of 3 factors and 19 items with a 5-point rating. The content validity was 0.91, Cronbach's alpha coefficient was 0.912, and the intraclass correlation coefficient for test-retest reliability was 0.953. The construct validity was good (χ 2 /df=2.440, RMSEA=0.068, NFI=0.907, CFI=0.942, IFI=0.430, p<0.001). The newly developed DRSES has proven good reliability and validity. It could therefore be used as an assessment tool to evaluate self-efficacy in disaster response for Chinese undergraduate nursing students. Copyright © 2017. Published by Elsevier Ltd.
Identifying and classifying hyperostosis frontalis interna via computerized tomography.
May, Hila; Peled, Nathan; Dar, Gali; Hay, Ori; Abbas, Janan; Masharawi, Youssef; Hershkovitz, Israel
2010-12-01
The aim of this study was to recognize the radiological characteristics of hyperostosis frontalis interna (HFI) and to establish a valid and reliable method for its identification and classification. A reliability test was carried out on 27 individuals who had undergone a head computerized tomography (CT) scan. Intra-observer reliability was obtained by examining the images three times, by the same researcher, with a 2-week interval between each sample ranking. The inter-observer test was performed by three independent researchers. A validity test was carried out using two methods for identifying and classifying HFI: 46 cadaver skullcaps were ranked twice via computerized tomography scans and then by direct observation. Reliability and validity were calculated using Kappa test (SPSS 15.0). Reliability tests of ranking HFI via CT scans demonstrated good results (K > 0.7). As for validity, a very good consensus was obtained between the CT and direct observation, when moderate and advanced types of HFI were present (K = 0.82). The suggested classification method for HFI, using CT, demonstrated a sensitivity of 84%, specificity of 90.5%, and positive predictive value of 91.3%. In conclusion, volume rendering is a reliable and valid tool for identifying HFI. The suggested three-scale classification is most suitable for radiological diagnosis of the phenomena. Considering the increasing awareness of HFI as an early indicator of a developing malady, this study may assist radiologists in identifying and classifying the phenomena.
ERIC Educational Resources Information Center
Yang, Hongfei; Hai, Tang
2015-01-01
The psychometrics of the Chinese Solution-Focused Inventory (CSFI) was studied in Chinese college students. Confirmatory factor analysis confirmed the 3-factor structure. All subscales showed good reliability and convergent and incremental validity. Results of hierarchical regression analyses indicated that the 3 subscales accounted for additional…
ERIC Educational Resources Information Center
Green, Carlton E.; Chen, Cynthia E.; Helms, Janet E.; Henze, Kevin T.
2011-01-01
Helms, Henze, Sass, and Mifsud (2006) defined good practices for internal consistency reporting, interpretation, and analysis consistent with an alpha-as-data perspective. Their viewpoint (a) expands on previous arguments that reliability coefficients are group-level summary statistics of samples' responses rather than stable properties of scales…
Establishing the Validity and Reliability of Course Evaluation Questionnaires
ERIC Educational Resources Information Center
Kember, David; Leung, Doris Y. P.
2008-01-01
This article uses the case of designing a new course questionnaire to discuss the issues of validity, reliability and diagnostic power in good questionnaire design. Validity is often not well addressed in course questionnaire design as there are no straightforward tests that can be applied to an individual instrument. The authors propose the…
NASA Astrophysics Data System (ADS)
Lin, Yi-Kuei; Huang, Cheng-Fu; Yeh, Cheng-Ta
2016-04-01
In supply chain management, satisfying customer demand is the most concerned for the manager. However, the goods may rot or be spoilt during delivery owing to natural disasters, inclement weather, traffic accidents, collisions, and so on, such that the intact goods may not meet market demand. This paper concentrates on a stochastic-flow distribution network (SFDN), in which a node denotes a supplier, a transfer station, or a market, while a route denotes a carrier providing the delivery service for a pair of nodes. The available capacity of the carrier is stochastic because the capacity may be partially reserved by other customers. The addressed problem is to evaluate the system reliability, the probability that the SFDN can satisfy the market demand with the spoilage rate under the budget constraint from multiple suppliers to the customer. An algorithm is developed in terms of minimal paths to evaluate the system reliability along with a numerical example to illustrate the solution procedure. A practical case of fruit distribution is presented accordingly to emphasise the management implication of the system reliability.
Composing, Analyzing and Validating Software Models
NASA Astrophysics Data System (ADS)
Sheldon, Frederick T.
1998-10-01
This research has been conducted at the Computational Sciences Division of the Information Sciences Directorate at Ames Research Center (Automated Software Engineering Grp). The principle work this summer has been to review and refine the agenda that were carried forward from last summer. Formal specifications provide good support for designing a functionally correct system, however they are weak at incorporating non-functional performance requirements (like reliability). Techniques which utilize stochastic Petri nets (SPNs) are good for evaluating the performance and reliability for a system, but they may be too abstract and cumbersome from the stand point of specifying and evaluating functional behavior. Therefore, one major objective of this research is to provide an integrated approach to assist the user in specifying both functionality (qualitative: mutual exclusion and synchronization) and performance requirements (quantitative: reliability and execution deadlines). In this way, the merits of a powerful modeling technique for performability analysis (using SPNs) can be combined with a well-defined formal specification language. In doing so, we can come closer to providing a formal approach to designing a functionally correct system that meets reliability and performance goals.
Kim, Sun Hee; Yoo, So Yeon; Kim, Yae Young
2018-02-01
This study was conducted to evaluate the validity and reliability of the Korean version of the clinical learning environment, supervision and nurse teacher evaluation scale (CLES+T) that measures the clinical learning environment and the conditions associated with supervision and nurse teachers. The English CLES+T was translated into Korean with forward and back translation. Survey data were collected from 434 nursing students who had more than four days of clinical practice in Korean hospitals. Internal consistency reliability and construct validity using confirmatory and exploratory factor analysis were conducted. SPSS 20.0 and AMOS 22.0 programs were used for data analysis. The exploratory factor analysis revealed seven factors for the thirty three-item scale. Confirmatory factor analysis supported good convergent and discriminant validities. The Cronbach's alpha for the overall scale was .94 and for the seven subscales ranged from .78 to .94. The findings suggest that the 33-items Korean CLES+T is an appropriate instrument to measure Korean nursing students'clinical learning environment with good validity and reliability. © 2018 Korean Society of Nursing Science.
Composing, Analyzing and Validating Software Models
NASA Technical Reports Server (NTRS)
Sheldon, Frederick T.
1998-01-01
This research has been conducted at the Computational Sciences Division of the Information Sciences Directorate at Ames Research Center (Automated Software Engineering Grp). The principle work this summer has been to review and refine the agenda that were carried forward from last summer. Formal specifications provide good support for designing a functionally correct system, however they are weak at incorporating non-functional performance requirements (like reliability). Techniques which utilize stochastic Petri nets (SPNs) are good for evaluating the performance and reliability for a system, but they may be too abstract and cumbersome from the stand point of specifying and evaluating functional behavior. Therefore, one major objective of this research is to provide an integrated approach to assist the user in specifying both functionality (qualitative: mutual exclusion and synchronization) and performance requirements (quantitative: reliability and execution deadlines). In this way, the merits of a powerful modeling technique for performability analysis (using SPNs) can be combined with a well-defined formal specification language. In doing so, we can come closer to providing a formal approach to designing a functionally correct system that meets reliability and performance goals.
[Inter-rater reliability and validity of the OPD-CA axes structure and conflict].
Benecke, Cord; Bock, Astrid; Wieser, Elke; Tschiesner, Reinhard; Lochmann, Martha; Küspert, Felicia; Schorn, Robert; Viertler, Bernhard; Steinmayr-Gensluckner, Maria
2011-01-01
The manual of the Operationalized Psychodynamic Diagnostics in childhood and adolescence (OPD-CA) is an instrument meanwhile widespread in the clinical practice to assess psychodynamic dimensions. Publications of inter-rater agreement and validity are still outstanding. This study assessed the interrater-reliability and validity for the axis structure and the axis conflict. 60 adolescents between 14 and 17 years, with and without psychic disorders, were diagnosed with the Operationalized Psychodynamic Diagnostics in childhood and adolescence (Arbeitskreis OPD-KJ, 2007) and SCID-II-interviews and questionnaires. A partial sample of 36 OPD-CA-interviews was the data basis for the assessment of inter-rater agreement. Calculations of validity for axis structure and axis conflict were made with the whole sample. Inter-rater agreement for the axis structure and the axis conflict showed good to very good weighted Kappa coefficients among the trained raters. Validity of the axis structure showed good results. The Operationalized Psychodynamic Diagnostics in childhood and adolescence (OPD-CA) allows a reliable diagnostic of axis structure and axis conflict, if the ratings are done on the basis of semistructured videotaped interviews by trained raters. The axis structure shows validity, while the results concerning the validity of the axis conflict remain unclear.
Akerman, Eva; Fridlund, Bengt; Ersson, Anders; Granberg-Axéll, Anetth
2009-04-01
Current studies reveal a lack of consensus for the evaluation of physical and psychosocial problems after ICU stay and their changes over time. The aim was to develop and evaluate the validity and reliability of a questionnaire for assessing physical and psychosocial problems over time for patients following ICU recovery. Thirty-nine patients completed the questionnaire, 17 were retested. The questionnaire was constructed in three sets: physical problems, psychosocial problems and follow-up care. Face and content validity were tested by nurses, researchers and patients. The questionnaire showed good construct validity in all three sets and had strong factor loadings (explained variance >70%, factor loadings >0.5) for all three sets. There was good concurrent validity compared with the SF 12 (r(s)>0.5). Internal consistency was shown to be reliable (Cronbach's alpha 0.70-0.85). Stability reliability on retesting was good for the physical and psychosocial sets (r(s)>0.5). The 3-set 4P questionnaire was a first step in developing an instrument for assessment of former ICU patients' problems over time. The sample size was small and thus, further studies are needed to confirm these findings.
Temporal Variation of HCO+ 1_0 Galactic Absorption Lines Toward NRAO 150 and BL Lac
NASA Astrophysics Data System (ADS)
Han, Junghwan; Yun, Youngjoo; Park, Yong-Sun
2017-12-01
We present observations of HCO^+ 1-0 absorption lines toward two extragalactic compact radio sources, NRAO 150 and BL Lac with the Korean VLBI Network in order to investigate their time variation over 20 years by Galactic foreground clouds. It is found that the line shape of -17 km s^{-1} component changed marginally during 1993-1998 period and has remained unaltered thereafter for NRAO 150. Its behavior is different from that of H_2CO 1_{10}-1_{11}, suggesting chemical differentiation on ˜ 20 AU scale, the smallest ever seen. On the other hand, BL Lac exhibits little temporal variation for the HCO^+ and H_2CO lines. Our observation also suggests that Korea VLBI Network performs reliably in the spectrum mode in that the shapes of the new HCO^+ 1-0 spectra are in good agreement with the previous ones to an accuracy of a few percent except the time varying component toward NRAO 150.
Carrera-Fernández, María Victoria; Lameiras-Fernández, María; Rodríguez-Castro, Yolanda; Vallejo-Medina, Pablo
2014-01-01
The aim of the present study was to develop and validate a short form of the Genderism and Transphobia Scale and assess adolescents' attitudes toward transpeople. A total of 800 Spanish adolescents aged between 14 and 18 years (50.70% girls, 49.30% boys) completed the Spanish version of the scale and other related questionnaires. The short form of the scale is composed of 12 items clustered into two factors (Transphobia/Genderism and Gender Bashing) that explain 54.22% of the variance. All the items showed good discriminating power, and the present scale demonstrated adequate reliability and validity. In the study, boys exhibited significantly more negative attitudes toward transpeople than girls did, both in the affective/cognitive dimension (Transphobia/Genderism) and in the behavioral dimension (Gender Bashing). Moreover, adolescents showed significantly more negative attitudes toward gender-nonconforming men than toward gender-nonconforming women. These results are discussed in terms of their relevance to the maintenance of discriminatory attitudes toward sexual diversity.
Lu, Dianchen; Ramzan, M; Ullah, Naeem; Chung, Jae Dong; Farooq, Umer
2017-12-05
A numerical investigation of steady three dimensional nanofluid flow carrying effects of gyrotactic microorganism with anisotropic slip condition along a moving plate near a stagnation point is conducted. Additionally, influences of Arrhenius activation energy, joule heating accompanying binary chemical reaction and viscous dissipation are also taken into account. A system of nonlinear differential equations obtained from boundary layer partial differential equations is found by utilization of apposite transformations. RK fourth and fifth order technique of Maple software is engaged to acquire the solution of the mathematical model governing the presented fluid flow. A Comparison with previously done study is also made and a good agreement is achieved with existing results; hence reliable results are being presented. Evaluations are carried out for involved parameters graphically against velocity, temperature, concentration fields, microorganism distribution, density number, local Nusselt and Sherwood numbers. It is detected that microorganism distribution exhibit diminishing behavior for rising values of bio-convection Lewis and Peclet numbers.
NASA Astrophysics Data System (ADS)
Kim, Dongha; Park, Hyungjin; Bae, Byeong-Soo
2016-03-01
In order to improve the reliability of TFT, an Al2O3 insulating layer is inserted between active fluorine doped indium zinc oxide (IZO:F) thin films to form a sandwiched triple layer. All the thin films were fabricated via low-cost sol-gel process. Due to its large energy bandgap and high bonding energy with oxygen atoms, the Al2O3 layer acts as a photo-induced positive charge blocking layer that effectively blocks the migration of both holes and V o2+ toward the interface between the gate insulator and the semiconductor. The inserted Al2O3 triple layer exhibits a noticeably low turn on voltage shift of -0.7 V under NBIS as well as the good TFT performance with a mobility of 10.9 cm2/V ṡ s. We anticipate that this approach can be used to solve the stability issues such as NBIS, which is caused by inescapable oxygen vacancies.
Li, Zhuo; Wang, Yong; Ni, Yongnian; Kokot, Serge
2015-02-25
A rapid and effective sensor for the analysis of nitrophenol-based explosive substances, represented by trinitrophenol (TNP), has been developed with the use of the blue luminescent graphene quantum dots (GQDs); these GQDs are derived from citric acid by a pyrolysis procedure. They emit strong blue fluorescence at 450 nm after excitation at 365 nm, and TNP can quench this fluorescence because a fluorescence resonance energy transfer occurs. The quenching ratio (F0-F)/F0 was related linearly to the concentration of TNP in the range of 0.1-15 μmol L(-1) with a detection limit of 0.091 μmol L(-1) (S/N=3). The developed method exhibits high sensitivity, good linearity and reliable reproducibility for the quantitative analysis of TNP in water samples. The GQDs were used directly without any further treatment or complicated modification. Copyright © 2014 Elsevier B.V. All rights reserved.
Cultural Awareness Among Nursing Staff at an Academic Medical Center.
McElroy, Jennifer; Smith-Miller, Cheryl A; Madigan, Catherine K; Li, Yin
2016-03-01
The goal is to identify areas for targeted improvement in regard to cultural awareness and competence among nursing staff and in the work environment. Many facilities have initiated programs to facilitate cultural competence development among nursing staff; however, there has been little examination of the effect of these initiatives, assessment of experienced nurses' cultural awareness, or investigation of nurse leader's role in promoting cultural competence in the literature. In this cross-sectional descriptive study, a cultural awareness survey was modified and electronically distributed to all registered nurses and assistive personnel at an academic medical center. The modified survey instrument showed good reliability and validity among the study population. Most nursing staff exhibited a moderate to high level of cultural awareness and held positive opinions about nursing leadership and the work environment with regard to cultural issues. In increasingly diverse work environments, assessing the cultural awareness of nursing staff enables nurse leaders to evaluate efforts in promoting cultural competence and to identify specific areas in which to target staff development efforts and leadership training.
Emerging technologies for V&V of ISHM software for space exploration
NASA Technical Reports Server (NTRS)
Feather, Martin S.; Markosian, Lawrence Z.
2006-01-01
Systems1,2 required to exhibit high operational reliability often rely on some form of fault protection to recognize and respond to faults, preventing faults' escalation to catastrophic failures. Integrated System Health Management (ISHM) extends the functionality of fault protection to both scale to more complex systems (and systems of systems), and to maintain capability rather than just avert catastrophe. Forms of ISHM have been utilized to good effect in the maintenance phase of systems' total lifecycles (often referred to as 'condition-based mainte-nance'), but less so in a 'fault protection' role during actual operations. One of the impediments to such use lies in the challenges of verification, validation and certification of ISHM systems themselves. This paper makes the case that state-of-the-practice V&V and certification techniques will not suffice for emerging forms of ISHM systems; however, a number of maturing software engineering assurance technologies show particular promise for addressing these ISHM V&V challenges.
The development and validation of the Relational Self-Esteem Scale.
Du, Hongfei; King, Ronnel B; Chi, Peilian
2012-06-01
According to the tripartite model of the self (Brewer & Gardner, 1996), the self consists of three aspects: personal, relational, and collective. Correspondingly, individuals can achieve a sense of self-worth through their personal attributes (personal self-esteem), relationship with significant others (relational self-esteem), or social group membership (collective self-esteem). Existing measures on personal and collective self-esteem are available in the literature; however, no scale exists that assesses relational self-esteem. The authors developed a scale to measure individual differences in relational self-esteem and tested it with two samples of Chinese university students. Between and within-network approaches to construct validation were used. The scale showed adequate internal consistency reliability and results of the confirmatory factor analysis showed good fit. It also exhibited meaningful correlations with theoretically relevant constructs in the nomological network. Implications and directions for future research are discussed. © 2012 The Authors. Scandinavian Journal of Psychology © 2012 The Scandinavian Psychological Associations.
Liu, Lantao; Zhou, Yanli; Kang, Yiyu; Huang, Haihong; Li, Congming; Xu, Maotian; Ye, Baoxian
2017-01-01
trans -Resveratrol is often considered as one of the quality standards of red wine, and the development of a sensitive and reliable method for monitoring the trans -resveratrol levels in red wine is an urgent requirement for the quality control. Here, a novel voltammetric approach was described for probing trans -resveratrol using a graphene-modified glassy carbon (GC) electrode. The proposed electrode was prepared by one-step electrodeposition of reduced graphene oxide (ERGO) at a GC electrode. Compared with the bare GC electrode, the introduced graphene film on the electrode surface dramatically improved the sensitivity of the sensor response due to the π - π interaction between the graphene and trans -resveratrol. The developed sensor exhibited low detection limit of 0.2 μ M with wide linear range of 0.8-32 μ M and high stability. For the analysis of trans -resveratrol in red wine, the high anti-interference ability and the good recoveries indicated the great potential for practical applications.
Liu, Lantao; Kang, Yiyu; Huang, Haihong; Li, Congming; Ye, Baoxian
2017-01-01
trans-Resveratrol is often considered as one of the quality standards of red wine, and the development of a sensitive and reliable method for monitoring the trans-resveratrol levels in red wine is an urgent requirement for the quality control. Here, a novel voltammetric approach was described for probing trans-resveratrol using a graphene-modified glassy carbon (GC) electrode. The proposed electrode was prepared by one-step electrodeposition of reduced graphene oxide (ERGO) at a GC electrode. Compared with the bare GC electrode, the introduced graphene film on the electrode surface dramatically improved the sensitivity of the sensor response due to the π-π interaction between the graphene and trans-resveratrol. The developed sensor exhibited low detection limit of 0.2 μM with wide linear range of 0.8–32 μM and high stability. For the analysis of trans-resveratrol in red wine, the high anti-interference ability and the good recoveries indicated the great potential for practical applications. PMID:28819581
Design of Instant Messaging System of Multi-language E-commerce Platform
NASA Astrophysics Data System (ADS)
Yang, Heng; Chen, Xinyi; Li, Jiajia; Cao, Yaru
2017-09-01
This paper aims at researching the message system in the instant messaging system based on the multi-language e-commerce platform in order to design the instant messaging system in multi-language environment and exhibit the national characteristics based information as well as applying national languages to e-commerce. In order to develop beautiful and friendly system interface for the front end of the message system and reduce the development cost, the mature jQuery framework is adopted in this paper. The high-performance server Tomcat is adopted at the back end to process user requests, and MySQL database is adopted for data storage to persistently store user data, and meanwhile Oracle database is adopted as the message buffer for system optimization. Moreover, AJAX technology is adopted for the client to actively pull the newest data from the server at the specified time. In practical application, the system has strong reliability, good expansibility, short response time, high system throughput capacity and high user concurrency.
Ozinga, Sarah J; Linder, Susan M; Alberts, Jay L
2017-04-01
To determine the accuracy of inertial measurement unit data from a mobile device using the mobile device relative to posturography to quantify postural stability in individuals with Parkinson disease (PD). Criterion standard. Motor control laboratory at a clinic. A sample (N=28) of individuals with mild to moderate PD (n=14) and age-matched community-dwelling individuals without PD (n=14) completed the study. Not applicable. Center of mass (COM) acceleration measures were compared between the mobile device and the NeuroCom force platform to determine the accuracy of mobile device measurements during performance of the Sensory Organization Test (SOT). Analyses examined test-retest reliability of both systems and sensitivity of (1) the equilibrium score from the SOT and (2) COM acceleration measures from the force platform and mobile device to quantify postural stability across populations. Metrics of COM acceleration from inertial measurement unit data and the NeuroCom force platform were significantly correlated across balance conditions and groups (Pearson r range, .35 to .97). The SOT equilibrium scores failed to discriminate individuals with and without PD. However, the multiplanar measures of COM acceleration from the mobile device exhibited good to excellent reliability across SOT conditions and were able to discriminate individuals with and without PD in conditions with the greatest balance demands. Metrics employing medial-lateral movement produce a more sensitive outcome than the equilibrium score in identifying postural instability associated with PD. Overall, the output from the mobile device provides an accurate and reliable method of rapidly quantifying balance in individuals with PD. The portable and affordable nature of a mobile device with the application makes it ideally suited to use biomechanical data to aid in clinical decision making. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Validity and reliability of the Nintendo Wii Balance Board for assessment of standing balance.
Clark, Ross A; Bryant, Adam L; Pua, Yonghao; McCrory, Paul; Bennell, Kim; Hunt, Michael
2010-03-01
Impaired standing balance has a detrimental effect on a person's functional ability and increases their risk of falling. There is currently no validated system which can precisely quantify center of pressure (COP), an important component of standing balance, while being inexpensive, portable and widely available. The Wii Balance Board (WBB) fits these criteria, and we examined its validity in comparison with the 'gold standard'-a laboratory-grade force platform (FP). Thirty subjects without lower limb pathology performed a combination of single and double leg standing balance tests with eyes open or closed on two separate occasions. Data from the WBB were acquired using a laptop computer. The test-retest reliability for COP path length for each of the testing devices, including a comparison of the WBB and FP data, was examined using intraclass correlation coefficients (ICC), Bland-Altman plots (BAP) and minimum detectable change (MDC). Both devices exhibited good to excellent COP path length test-retest reliability within-device (ICC=0.66-0.94) and between-device (ICC=0.77-0.89) on all testing protocols. Examination of the BAP revealed no relationship between the difference and the mean in any test, however the MDC values for the WBB did exceed those of the FP in three of the four tests. These findings suggest that the WBB is a valid tool for assessing standing balance. Given that the WBB is portable, widely available and a fraction of the cost of a FP, it could provide the average clinician with a standing balance assessment tool suitable for the clinical setting. Copyright 2009 Elsevier B.V. All rights reserved.
Skritskaya, Natalia A; Mauro, Christine; Olonoff, Matthew; Qiu, Xin; Duncan, Sarah; Wang, Yuanjia; Duan, Naihua; Lebowitz, Barry; Reynolds, Charles F; Simon, Naomi M; Zisook, Sidney; Shear, M Katherine
2017-05-01
Maladaptive cognitions related to loss are thought to contribute to development of complicated grief and are crucial to address in treatment, but tools available to assess them are limited. This paper introduces the Typical Beliefs Questionnaire (TBQ), a 25-item self-report instrument to assess cognitions that interfere with adaptation to loss. Study participants completed an assessment battery during their initial evaluation and again after completing treatment at 20 weeks. Test-retest reliability was assessed on a subsample of the participants who did not show change in complicated grief severity after the first 4 weeks of treatment. To examine latent structure of the TBQ, an exploratory factor analysis (EFA) was performed. Academic medical centers in Boston, New York, Pittsburgh, and San Diego from 2010-2014. 394 bereaved adults who met criteria for complicated grief. The TBQ along with assessments of complicated grief symptoms and related avoidance, depression symptoms, functional impairment, and perceived social support. The TBQ exhibited good internal consistency (α = 0.82) and test-retest reliability (N = 105; intraclass correlation coefficient = 0.74). EFA indicated a five-factor structure: "Protesting the Death," "Negative Thoughts About the World," "Needing the Person," "Less Grief is Wrong" and "Grieving Too Much." The total score and all factors showed sensitivity to change with treatment. This new tool allows a clinician to quickly and reliably ascertain presence of specific maladaptive cognitions related to complicated grief, and subsequently, to use the information to aid a diagnostic assessment, to structure the treatment, and to measure treatment outcomes. Copyright © 2016 American Association for Geriatric Psychiatry. Published by Elsevier Inc. All rights reserved.
The Multimedia Activity Recall for Children and Adolescents (MARCA): development and evaluation.
Ridley, Kate; Olds, Tim S; Hill, Alison
2006-05-26
Self-report recall questionnaires are commonly used to measure physical activity, energy expenditure and time use in children and adolescents. However, self-report questionnaires show low to moderate validity, mainly due to inaccuracies in recalling activity in terms of duration and intensity. Aside from recall errors, inaccuracies in estimating energy expenditure from self-report questionnaires are compounded by a lack of data on the energy cost of everyday activities in children and adolescents. This article describes the development of the Multimedia Activity Recall for Children and Adolescents (MARCA), a computer-delivered use-of-time instrument designed to address both the limitations of self-report recall questionnaires in children, and the lack of energy cost data in children. The test-retest reliability of the MARCA was assessed using a sample of 32 children (aged 11.8 +/- 0.7 y) who undertook the MARCA twice within 24-h. Criterion validity was assessed by comparing self-reports with accelerometer counts collected on a sample of 66 children (aged 11.6 +/- 0.8 y). Content and construct validity were assessed by establishing whether data collected using the MARCA on 1429 children (aged 11.9 +/- 0.8 y) exhibited relationships and trends in children's physical activity consistent with established findings from a number of previous research studies. Test-retest reliability was high with intra-class coefficients ranging from 0.88 to 0.94. The MARCA demonstrated criterion validity comparable to other self-report instruments with Spearman coefficients ranging from rho = 0.36 to 0.45, and provided evidence of good content and construct validity. The MARCA is a valid and reliable self-report questionnaire, capable of a wide variety of flexible use-of-time analyses related to both physical activity and sedentary behaviour, and offers advantages over existing pen-and-paper questionnaires.
Böttcher, B; Fessler, S; Friedl, F; Toth, B; Walter, M H; Wildt, L; Riedl, D
2018-04-01
Patients with polycystic ovary syndrome (PCOS) report a decreased health-related quality of life (HRQOL) and higher levels of psychological distress. Validated questionnaires are necessary to assess the impact of PCOS on patients' lives. The aim of the present study was to evaluate the German "Polycystic Ovary Syndrome Questionnaire" (PCOSQ-G). The psychometric properties of the PCOSQ-G were investigated in PCOS patients with item-total correlation, internal consistency and test-retest reliability. Correlations with the Short-Form-36 Health Survey (SF-36) and the Hospital Anxiety and Depression Scale (HADS-D) were calculated to evaluate the validity of the PCOSQ-G. Discriminatory validity was investigated through a receiver operating characteristic curve and independent sample t tests compared with healthy controls. Good psychometric properties were found for most items. Acceptable to high internal consistency was found for the total score (α = 0.94-0.95) and all subscales (α = 0.70-0.97). High test-retest reliability was found for the total score (0.86) and all subscales (0.81-0.90). The validity analyses showed that the PCOSQ-G total score was positively correlated with both SF-36 summary scales and was negatively correlated with both HADS subscales. Patients reported significantly lower values for the PCOSQ-G total score (p < 0.001) and all subscales, and the PCOSQ-G discriminated well between patients and healthy controls (AUC = 0.81, p < 0.001). PCOSQ-G is a reliable and valid tool to assess the HRQOL in patients with PCOS and can be used in future clinical research. Patients with PCOS exhibited an impaired HRQOL, which indicates the need for psychosomatic counseling.
Reverse engineering a gene network using an asynchronous parallel evolution strategy
2010-01-01
Background The use of reverse engineering methods to infer gene regulatory networks by fitting mathematical models to gene expression data is becoming increasingly popular and successful. However, increasing model complexity means that more powerful global optimisation techniques are required for model fitting. The parallel Lam Simulated Annealing (pLSA) algorithm has been used in such approaches, but recent research has shown that island Evolutionary Strategies can produce faster, more reliable results. However, no parallel island Evolutionary Strategy (piES) has yet been demonstrated to be effective for this task. Results Here, we present synchronous and asynchronous versions of the piES algorithm, and apply them to a real reverse engineering problem: inferring parameters in the gap gene network. We find that the asynchronous piES exhibits very little communication overhead, and shows significant speed-up for up to 50 nodes: the piES running on 50 nodes is nearly 10 times faster than the best serial algorithm. We compare the asynchronous piES to pLSA on the same test problem, measuring the time required to reach particular levels of residual error, and show that it shows much faster convergence than pLSA across all optimisation conditions tested. Conclusions Our results demonstrate that the piES is consistently faster and more reliable than the pLSA algorithm on this problem, and scales better with increasing numbers of nodes. In addition, the piES is especially well suited to further improvements and adaptations: Firstly, the algorithm's fast initial descent speed and high reliability make it a good candidate for being used as part of a global/local search hybrid algorithm. Secondly, it has the potential to be used as part of a hierarchical evolutionary algorithm, which takes advantage of modern multi-core computing architectures. PMID:20196855
Montero-Marín, Jesús; García-Campayo, Javier
2010-06-02
Burnout syndrome has been clinically characterised by a series of three subtypes: frenetic, underchallenged, and worn-out, with reference to coping strategies for stress and frustration at work with different degrees of dedication. The aims of the study are to present an operating definition of these subtypes in order to assess their reliability and convergent validity with respect to a standard burnout criterion and to examine differences with regard to sex and the temporary nature of work contracts. An exploratory factor analysis was performed by the main component method on a range of items devised by experts. The sample was composed of 409 employees of the University of Zaragoza, Spain. The reliability of the scales was assessed with Cronbach's alpha, convergent validity in relation to the Maslach Burnout Inventory with Pearson's r, and differences with Student's t-test and the Mann-Whitney U test. The factorial validity and reliability of the scales were good. The subtypes presented relations of differing degrees with the criterion dimensions, which were greater when dedication to work was lower. The frenetic profile presented fewer relations with the criterion dimensions while the worn-out profile presented relations of the greatest magnitude. Sex was not influential in establishing differences. However, the temporary nature of work contracts was found to have an effect: temporary employees exhibited higher scores in the frenetic profile (p < 0.001), while permanent employees did so in the underchallenged (p = 0.018) and worn-out (p < 0.001) profiles. The classical Maslach description of burnout does not include the frenetic profile; therefore, these patients are not recognised. The developed questionnaire may be a useful tool for the design and appraisal of specific preventive and treatment approaches based on the type of burnout experienced.
Kosteniuk, Julie G; Wilson, Erin C; Penz, Kelly L; MacLeod, Martha L P; Stewart, Norma J; Kulig, Judith C; Karunanayake, Chandima P; Kilpatrick, Kelley
2016-01-01
To report the development and psychometric evaluation of a scale to measure rural and remote (rural/remote) nurses' perceptions of the engagement of their workplaces in key dimensions of primary health care (PHC). Amidst ongoing PHC reforms, a comprehensive instrument is needed to evaluate the degree to which rural/remote health care settings are involved in the key dimensions that characterize PHC delivery, particularly from the perspective of professionals delivering care. This study followed a three-phase process of instrument development and psychometric evaluation. A literature review and expert consultation informed instrument development in the first phase, followed by an iterative process of content evaluation in the second phase. In the final phase, a pilot survey was undertaken and item discrimination analysis employed to evaluate the internal consistency reliability of each subscale in the preliminary 60-item Primary Health Care Engagement (PHCE) Scale. The 60-item scale was subsequently refined to a 40-item instrument. The pilot survey sample included 89 nurses in current practice who had experience in rural/remote practice settings. Participants completed either a web-based or paper survey from September to December, 2013. Following item discrimination analysis, the 60-item instrument was refined to a 40-item PHCE Scale consisting of 10 subscales, each including three to five items. Alpha estimates of the 10 refined subscales ranged from 0.61 to 0.83, with seven of the subscales demonstrating acceptable reliability (α ⩾ 0.70). The refined 40-item instrument exhibited good internal consistency reliability (α=0.91). The 40-item PHCE Scale may be considered for use in future studies regardless of locale, to measure the extent to which health care professionals perceive their workplaces to be engaged in key dimensions of PHC.
Cairnduff, Victoria; Dean, Moira; Koidis, Anastasios
2016-09-01
Food preparation and storage behaviors in the home deviating from the "best practice" food safety recommendations may result in foodborne illnesses. Currently, there are limited tools available to fully evaluate the consumer knowledge, perceptions, and behavior in the area of refrigerator safety. The current study aimed to develop a valid and reliable tool in the form of a questionnaire, the Consumer Refrigerator Safety Questionnaire (CRSQ), for assessing systematically all these aspects. Items relating to refrigerator safety knowledge (n =17), perceptions (n =46), and reported behavior (n =30) were developed and pilot tested by an expert reference group and various consumer groups to assess face and content validity (n =20), item difficulty and consistency (n =55), and construct validity (n =23). The findings showed that the CRSQ has acceptable face and content validity with acceptable levels of item difficulty. Item consistency was observed for 12 of 15 in refrigerator safety knowledge. Further, all 5 of the subscales of consumer perceptions of refrigerator safety practices relating to risk of developing foodborne disease showed acceptable internal consistency (Cronbach's α value > 0.8). Construct validity of the CRSQ was shown to be very good (P = 0.022). The CRSQ exhibited acceptable test-retest reliability at 14 days with the majority of knowledge items (93.3%) and reported behavior items (96.4%) having correlation coefficients of greater than 0.70. Overall, the CRSQ was deemed valid and reliable in assessing refrigerator safety knowledge and behavior; therefore, it has the potential for future use in identifying groups of individuals at increased risk of deviating from recommended refrigerator safety practices, as well as the assessment of refrigerator safety knowledge and behavior for use before and after an intervention.
A targeted metabolomic protocol for short-chain fatty acids and branched-chain amino acids.
Zheng, Xiaojiao; Qiu, Yunping; Zhong, Wei; Baxter, Sarah; Su, Mingming; Li, Qiong; Xie, Guoxiang; Ore, Brandon M; Qiao, Shanlei; Spencer, Melanie D; Zeisel, Steven H; Zhou, Zhanxiang; Zhao, Aihua; Jia, Wei
2013-08-01
Research in obesity and metabolic disorders that involve intestinal microbiota demands reliable methods for the precise measurement of the short-chain fatty acids (SCFAs) and branched-chain amino acids (BCAAs) concentration. Here, we report a rapid method of simultaneously determining SCFAs and BCAAs in biological samples using propyl chloroformate (PCF) derivatization followed by gas chromatography mass spectrometry (GC-MS) analysis. A one-step derivatization using 100 µL of PCF in a reaction system of water, propanol, and pyridine (v/v/v = 8:3:2) at pH 8 provided the optimal derivatization efficiency. The best extraction efficiency of the derivatized products was achieved by a two-step extraction with hexane. The method exhibited good derivatization efficiency and recovery for a wide range of concentrations with a low limit of detection for each compound. The relative standard deviations (RSDs) of all targeted compounds showed good intra- and inter-day (within 7 days) precision (< 10%), and good stability (< 20%) within 4 days at room temperature (23-25 °C), or 7 days when stored at -20 °C. We applied our method to measure SCFA and BCAA levels in fecal samples from rats administrated with different diet. Both univariate and multivariate statistics analysis of the concentrations of these target metabolites could differentiate three groups with ethanol intervention and different oils in diet. This method was also successfully employed to determine SCFA and BCAA in the feces, plasma and urine from normal humans, providing important baseline information of the concentrations of these metabolites. This novel metabolic profile study has great potential for translational research.
Petrova, Tatjana; Kavookjian, Jan; Madson, Michael B; Dagley, John; Shannon, David; McDonough, Sharon K
2015-01-01
Motivational interviewing (MI) has demonstrated a significant impact as an intervention strategy for addiction management, change in lifestyle behaviors, and adherence to prescribed medication and other treatments. Key elements to studying MI include training in MI of professionals who will use it, assessment of skills acquisition in trainees, and the use of a validated skills assessment tool. The purpose of this research project was to develop a psychometrically valid and reliable tool that has been designed to assess MI skills competence in health care provider trainees. The goal was to develop an assessment tool that would evaluate the acquisition and use of specific MI skills and principles, as well as the quality of the patient-provider therapeutic alliance in brief health care encounters. To address this purpose, specific steps were followed, beginning with a literature review. This review contributed to the development of relevant conceptual and operational definitions, selecting a scaling technique and response format, and methods for analyzing validity and reliability. Internal consistency reliability was established on 88 video recorded interactions. The inter-rater and test-retest reliability were established using randomly selected 18 from the 88 interactions. The assessment tool Motivational Interviewing Skills for Health Care Encounters (MISHCE) and a manual for use of the tool were developed. Validity and reliability of MISHCE were examined. Face and content validity were supported with well-defined conceptual and operational definitions and feedback from an expert panel. Reliability was established through internal consistency, inter-rater reliability, and test-retest reliability. The overall internal consistency reliability (Cronbach's alpha) for all fifteen items was 0.75. MISHCE demonstrated good inter-rater reliability and good to excellent test-retest reliability. MISHCE assesses the health provider's level of knowledge and skills in brief disease management encounters. MISHCE also evaluates quality of the patient-provider therapeutic alliance, i.e., the "flow" of the interaction. Copyright © 2015 Elsevier Inc. All rights reserved.
The development and validation of a test of science critical thinking for fifth graders.
Mapeala, Ruslan; Siew, Nyet Moi
2015-01-01
The paper described the development and validation of the Test of Science Critical Thinking (TSCT) to measure the three critical thinking skill constructs: comparing and contrasting, sequencing, and identifying cause and effect. The initial TSCT consisted of 55 multiple choice test items, each of which required participants to select a correct response and a correct choice of critical thinking used for their response. Data were obtained from a purposive sampling of 30 fifth graders in a pilot study carried out in a primary school in Sabah, Malaysia. Students underwent the sessions of teaching and learning activities for 9 weeks using the Thinking Maps-aided Problem-Based Learning Module before they answered the TSCT test. Analyses were conducted to check on difficulty index (p) and discrimination index (d), internal consistency reliability, content validity, and face validity. Analysis of the test-retest reliability data was conducted separately for a group of fifth graders with similar ability. Findings of the pilot study showed that out of initial 55 administered items, only 30 items with relatively good difficulty index (p) ranged from 0.40 to 0.60 and with good discrimination index (d) ranged within 0.20-1.00 were selected. The Kuder-Richardson reliability value was found to be appropriate and relatively high with 0.70, 0.73 and 0.92 for identifying cause and effect, sequencing, and comparing and contrasting respectively. The content validity index obtained from three expert judgments equalled or exceeded 0.95. In addition, test-retest reliability showed good, statistically significant correlations ([Formula: see text]). From the above results, the selected 30-item TSCT was found to have sufficient reliability and validity and would therefore represent a useful tool for measuring critical thinking ability among fifth graders in primary science.
Kahraman, Turhan; Genç, Arzu; Göz, Evrim
2016-10-01
The purpose of this study was to linguistically and culturally adapt the Nordic Musculoskeletal Questionnaire (NMQ) for use in Turkey, and to examine the psychometric properties of this adapted version. The cross-cultural adaptation was achieved by translating the items from the original version, with back-translation performed by independent mother-tongue translators, followed by committee review. Reliability (internal consistency and test-retest) was examined for 198 participants who completed the NMQ twice (with a 1 week interval). Construct validity was examined with data from 126 participants from the same population, who completed further four questionnaires related to the body regions described in the NMQ. The internal consistency was excellent (Cronbach's alpha = 0.896). The test-retest reliability was examined with the prevalence-adjusted bias-adjusted kappa (PABAK) and all items showed moderate to almost perfect reliability (PABAK = 0.57-0.90). Participants with a musculoskeletal problem in a related region had significantly more disability/pain, as assessed by the relevant questionnaires (p < 0.001), indicating that the NMQ had a good construct validity. This study provided considerable evidence that the Turkish version of the NMQ has appropriate psychometric properties, including good test-retest reliability, internal consistency and construct validity. It can be used for screening and epidemiological investigations of musculoskeletal symptoms. Implications for Rehabilitation The Nordic Musculoskeletal Questionnaire (NMQ) can be used for the screening of musculoskeletal problems. The NMQ allows comparison of musculoskeletal problems in different body regions in epidemiological studies with large numbers of participants. The Turkish version of the NMQ can be used for rehabilitation due to its appropriate psychometric properties, including good test-retest reliability, internal consistency and construct validity.
Dang, Weimin; Cheng, Wenhong; Ma, Hong; Lin, Jin; Wu, Baoming; Ma, Ning; Wang, Rongke; Xu, Junting; Zhou, Tianhang; Yu, Xin
2015-06-01
To evaluate the reliability and validity of Professional Quality of Life Scale (ProQOL-30, 4th version, 30 items) among government staff in the Wenchuan earthquake-stricken areas A total of 1,175 members of government staff in the Wenchuan earthquake-stricken areas were selected by convenience sampling and required to complete the ProQOL and Self-Reporting Questionnair (SRQ). The reliability and validity of the scale was evaluated by correlation analysis, t-test, and confirmatory factor analysis. Item-total correlation coefficients of the three subscales were 0.590 - 0.752, 0.389 - 0.603, and 0.340 - 0.647, respectively (P<0.05), and the average coefficients were 0.672, 0.482, and 0.555 respectively (P<0.05). The Cronbach's α coefficients of the three subscales were 0.864, 0.569, and 0.742 respectively, and the split-half reliabilities were 0.829, 0.490, and 0.677, respectively. P value was 0.88 in thE chi-square test of confirmatory factor analysis model. Goodness-of-fit indices of ProQOL-30 included GFI=0.895 NFI=0.856, CFI=0.895, RMSEA=0.063, and AGFI=0.912. For the ProQOL-28 as an optimized version o ProQOL-30, the Cronbach's a coefficients for burnout and trauma/compassion fatigue increased to 0.616 and 0.757, respectively. P value was 0.91 in the chi-square test of confirmatory factor analysis model test. Goodness-of-fit indices of ProQOL-28 were GFI =0.913, AGFI =0.924, NFI =0.900, CFI =0.913, and RMSEA =0.031 CONCLUSION: ProQOL-28 has good reliability and validity among government staff in the earthquake-stricker areas in China.
Schaefer, Lauren M; Harriger, Jennifer A; Heinberg, Leslie J; Soderberg, Taylor; Kevin Thompson, J
2017-02-01
The Sociocultural Attitudes Toward Appearance Questionnaire-4 (SATAQ-4) is a measure of internalization of appearance ideals (i.e., personal acceptance of societal ideals) and appearance pressures (i.e., pressures to achieve the societal ideal). The current study sought to address limitations of the scale in order to increase precision in the measurement of muscular ideal internalization, include an assessment of one's desire for attractiveness, and broaden the measurement of appearance-related pressures. The factor structure, reliability and construct validity of the SATAQ-4-Revised were examined among college women (N = 1,114) in Study 1, adolescent girls (N = 275) in Study 2, and college men (N = 290) in Study 3. Factor analysis among college women indicated a 7-factor 31-item scale, labeled the SATAQ-4R-Female: (1) Internalization: Thin/Low Body Fat, (2) Internalization: Muscular, (3) Internalization: General Attractiveness, (4) Pressures: Family, (5) Pressures: Media, (6) Pressures: Peers, and (7) Pressures: Significant Others. SATAQ-4R-Female subscales demonstrated good reliability and construct validity among college women. Examination of the SATAQ-4R-Female among adolescent girls suggested a six-factor scale in which peer and significant others items comprised a single subscale. The scale demonstrated good reliability and construct validity in adolescent girls. Examination of the SATAQ-4R among men produced a 28-item scale with seven factors paralleling the factors identified among college women. This scale, labeled the SATAQ-4R-Male, demonstrated good reliability and construct validity. Results support the reliability and validity of SATAQ-4R-Female in college women and adolescent girls, and the SATAQ-4R-Male in college men. © 2016 Wiley Periodicals, Inc.(Int J Eat Disord 2017; 50:104-117). © 2016 Wiley Periodicals, Inc.
Singh, Varun Pratap; Singh, Rajkumar
2014-03-01
The aim of this study was to develop a reliable and valid Nepali version of the Psychosocial Impact of Dental Aesthetic Questionnaire (PIDAQ). Cross-sectional descriptive validation study. B.P. Koirala Institute of Health Sciences, Dharan, Nepal. A rigorous translation process including conceptual and semantic evaluation, translation, back translation and pre-testing was carried out. Two hundred and fifty-two undergraduates, including equal numbers of males and females with an age ranging from 18 to 29 years (mean age: 22·33±2·114 years), participated in this study. Reliability was assessed by Cronbach's alpha coefficient and the coefficient of correlation was used to assess correlation between items and test-retest reliability. The construct validity was tested by factorial analysis. Convergent construct validity was tested by comparison of PIDAQ scores with the aesthetic component of the index of orthodontic treatment needs (IOTN-AC) and perception of occlusion scale (POS), respectively. Discriminant construct validity was assessed by differences in score for those who demand treatment and those who did not. The response rate was 100%. One hundred and twenty-three individuals had a demand for orthodontic treatment. The Nepali PIDAQ had excellent reliability with Cronbach's alpha of 0·945, corrected item correlation between 0·525 and 0·790 and overall test-retest reliability of 0·978. The construct validity was good with formation of a new sub-domain 'Dental self-consciousness'. The scale had good correlation with IOTN-AC and POS fulfilling convergent construct validity. The discriminant construct validity was proved by significant differences in scores for subjects with demand and without demand for treatment. To conclude, Nepali version of PIDAQ has good psychometric properties and can be used effectively in this population group for further research.
Cross-cultural adaptation of VISA-P score for patellar tendinopathy in Turkish population.
Çelebi, Mehmet Mesut; Köse, Serdal Kenan; Akkaya, Zehra; Zergeroglu, Ali Murat
2016-01-01
VISA-P questionnaire assesses to severity of symptoms and treatment effects in athletes with patellar tendinopathy. The purpose of this study was to translated VISA-P questionnaire into Turkish language and to determine its validity and reliability. The English version of VISA-P questionnaire was translated into Turkish according to the internationally recommended guidelines. Test-retest reliability was determined on 89 participants with time interval 24 h. To determine validity of Turkish VISA-P, 31 (17 male, 14 female) healthy students, 34 (20 male, 14 female) patients with patellar tendinopathy (diagnosed by physical examination and ultrasonography) and 24 (16 male, 8 female) volleyball players (at risk populations) were completed VISA-P-Tr. Internal consistency was determined with Cronbach's alpha. Intraclass correlation coefficients (ICCs) were calculated to analyse test-retest reliability. To assessment of discrimination, VISA-P-Tr scores compared all groups using the Mann-Whitney-U test. The VISA-P-Tr questionnaire showed good test-retest reliability (The Cronbach's alpha was 0.79 and 0.78 respectively and ICC was 0.96). The VISA-P-Tr score (mean ± SD) were 93.7 ± 8.9 and 94.0 ± 8.1 for healthy students, 81.1 ± 13.7 and 80.7 ± 13.4 for volleyball players, 58.8 ± 12.1 and 58.5 ± 11.0 for athletes with patellar tendinopathy. The translated Turkish version of VISA-P has good internal consistency and good reliability and validity. Therefore VISA-P-Tr is useful to evaluate symptoms and follow the treatment effect in athletes with patellar tendinopathy.
[Multiple mini interviews before the occupation of main training posts in paediatrics].
Hertel, Niels Thomas; Bjerager, Mia; Boas, Malene; Boisen, Kirsten A; Børch, Klaus; Frederiksen, Marianne Sjølin; Holm, Kirsten; Grum-Nymann, Anette; Johnsen, Martin M; Whitehouse, Stine; Balslev, Thomas
2013-09-09
Interviews are mandatory in Denmark when selecting doctors for training positions. We used multiple mini interviews (MMI) at four recruitment rounds for the main training posts in paediatrics. In total, 125 candidates were evaluated and assessed by CV and MMI (4-5 stations). Reliability for individual stations in MMI assessed by Cronbach's alpha was adequate (0.63-0.92). The overall reliability assessed by G-theory was lower, suggesting that different skills were tested. The acceptability was high. Our experiences with MMI suggest good feasibility and reliability. An increasing number of stations may improve the overall reliability.
Alsous, Mervat; Alhalaiqa, Fadwa; Abu Farha, Rana; Abdel Jalil, Mariam; McElnay, James; Horne, Robert
2017-01-01
Objectives to evaluate the reliability and discriminant validity of Arabic translation of the Medication Adherence Report Scale (MARS) and the Beliefs about Medication Questionnaire-specific (BMQ-specific). Methods Having developed Arabic translations of the study instruments, a cross-sectional study was carried out between March and October 2015 in two multidisciplinary governmental hospitals in Jordan. An expert panel monitored the forward and backward translation of the MARS and BMQ. Standard Arabic was used (with no specific dialect inclusion) to allow greater generalisability across Arabic speaking countries. Once the Arabic translations of the questionnaires were developed they were tested for consistency, validity and reliability on a group of children with chronic diseases and their parents. Results A total of 258 parents and 208 children were included in the study. The median age of participated children and parents was 15 years and 42 years respectively. Principle component analysis of all questionnaires indicated that all had good construct validity as they clearly measured one construct. The questionnaires were deemed reliable based on the results of Cronbach alpha coefficient. Furthermore, reliability of the questionnaires was demonstrated by test-retest intraclass correlation coefficients (ICC) which ranged from good to excellent for all scales (ICC>0.706). The Pearson correlation coefficient ranged from 0.546–0.805 for the entire sample which indicated a significant moderate to strong positive correlation between MARS and BMQ items at time 1 and 2. Reported adherence was greater than 59% using MARS-children and MARS-parents scales, and was correlated with beliefs in necessity and independent of the concerns regarding medications. Conclusion The Arabic translations of both BMQ and MARS for use in children and their parents have good internal consistency and proved to be valid and reliable tools that can be used by researchers in clinical practice to measure adherence and beliefs about medications in Arabic speaking patient populations. PMID:28192467
Ruschel, Caroline; Haupenthal, Alessandro; Jacomel, Gabriel Fernandes; Fontana, Heiliane de Brito; Santos, Daniela Pacheco dos; Scoz, Robson Dias; Roesler, Helio
2015-05-20
Isometric muscle strength of knee extensors has been assessed for estimating performance, evaluating progress during physical training, and investigating the relationship between isometric and dynamic/functional performance. To assess the validity and reliability of an adapted leg-extension machine for measuring isometric knee extensor force. Validity (concurrent approach) and reliability (test and test-retest approach) study. University laboratory. 70 healthy men and women aged between 20 and 30 y (39 in the validity study and 31 in the reliability study). Intraclass correlation coefficient (ICC) values calculated for the maximum voluntary isometric torque of knee extensors at 30°, 60°, and 90°, measured with the prototype and with an isokinetic dynamometer (ICC2,1, validity study) and measured with the prototype in test and retest sessions, scheduled from 48 h to 72 h apart (ICC1,1, reliability study). In the validity analysis, the prototype showed good agreement for measurements at 30° (ICC2,1 = .75, SEM = 18.2 Nm) and excellent agreement for measurements at 60° (ICC2,1 = .93, SEM = 9.6 Nm) and at 90° (ICC2,1 = .94, SEM = 8.9 Nm). Regarding the reliability analysis, between-days' ICC1,1 were good to excellent, ranging from .88 to .93. Standard error of measurement and minimal detectable difference based on test-retest ranged from 11.7 Nm to 18.1 Nm and 32.5 Nm to 50.1 Nm, respectively, for the 3 analyzed knee angles. The analysis of validity and repeatability of the prototype for measuring isometric muscle strength has shown to be good or excellent, depending on the knee joint angle analyzed. The new instrument, which presents a relative low cost and easiness of transportation when compared with an isokinetic dynamometer, is valid and provides consistent data concerning isometric strength of knee extensors and, for this reason, can be used for practical, clinical, and research purposes.
Alsous, Mervat; Alhalaiqa, Fadwa; Abu Farha, Rana; Abdel Jalil, Mariam; McElnay, James; Horne, Robert
2017-01-01
to evaluate the reliability and discriminant validity of Arabic translation of the Medication Adherence Report Scale (MARS) and the Beliefs about Medication Questionnaire-specific (BMQ-specific). Having developed Arabic translations of the study instruments, a cross-sectional study was carried out between March and October 2015 in two multidisciplinary governmental hospitals in Jordan. An expert panel monitored the forward and backward translation of the MARS and BMQ. Standard Arabic was used (with no specific dialect inclusion) to allow greater generalisability across Arabic speaking countries. Once the Arabic translations of the questionnaires were developed they were tested for consistency, validity and reliability on a group of children with chronic diseases and their parents. A total of 258 parents and 208 children were included in the study. The median age of participated children and parents was 15 years and 42 years respectively. Principle component analysis of all questionnaires indicated that all had good construct validity as they clearly measured one construct. The questionnaires were deemed reliable based on the results of Cronbach alpha coefficient. Furthermore, reliability of the questionnaires was demonstrated by test-retest intraclass correlation coefficients (ICC) which ranged from good to excellent for all scales (ICC>0.706). The Pearson correlation coefficient ranged from 0.546-0.805 for the entire sample which indicated a significant moderate to strong positive correlation between MARS and BMQ items at time 1 and 2. Reported adherence was greater than 59% using MARS-children and MARS-parents scales, and was correlated with beliefs in necessity and independent of the concerns regarding medications. The Arabic translations of both BMQ and MARS for use in children and their parents have good internal consistency and proved to be valid and reliable tools that can be used by researchers in clinical practice to measure adherence and beliefs about medications in Arabic speaking patient populations.
Validation of different pediatric triage systems in the emergency department
Aeimchanbanjong, Kanokwan; Pandee, Uthen
2017-01-01
BACKGROUND: Triage system in children seems to be more challenging compared to adults because of their different response to physiological and psychosocial stressors. This study aimed to determine the best triage system in the pediatric emergency department. METHODS: This was a prospective observational study. This study was divided into two phases. The first phase determined the inter-rater reliability of five triage systems: Manchester Triage System (MTS), Emergency Severity Index (ESI) version 4, Pediatric Canadian Triage and Acuity Scale (CTAS), Australasian Triage Scale (ATS), and Ramathibodi Triage System (RTS) by triage nurses and pediatric residents. In the second phase, to analyze the validity of each triage system, patients were categorized as two groups, i.e., high acuity patients (triage level 1, 2) and low acuity patients (triage level 3, 4, and 5). Then we compared the triage acuity with actual admission. RESULTS: In phase I, RTS illustrated almost perfect inter-rater reliability with kappa of 1.0 (P<0.01). ESI and CTAS illustrated good inter-rater reliability with kappa of 0.8–0.9 (P<0.01). Meanwhile, ATS and MTS illustrated moderate to good inter-rater reliability with kappa of 0.5–0.7 (P<0.01). In phase II, we included 1 041 participants with average age of 4.7±4.2 years, of which 55% were male and 45% were female. In addition 32% of the participants had underlying diseases, and 123 (11.8%) patients were admitted. We found that ESI illustrated the most appropriate predicting ability for admission with sensitivity of 52%, specificity of 81%, and AUC 0.78 (95%CI 0.74–0.81). CONCLUSION: RTS illustrated almost perfect inter-rater reliability. Meanwhile, ESI and CTAS illustrated good inter-rater reliability. Finally, ESI illustrated the appropriate validity for triage system. PMID:28680520
Noise-constrained switching times for heteroclinic computing
NASA Astrophysics Data System (ADS)
Neves, Fabio Schittler; Voit, Maximilian; Timme, Marc
2017-03-01
Heteroclinic computing offers a novel paradigm for universal computation by collective system dynamics. In such a paradigm, input signals are encoded as complex periodic orbits approaching specific sequences of saddle states. Without inputs, the relevant states together with the heteroclinic connections between them form a network of states—the heteroclinic network. Systems of pulse-coupled oscillators or spiking neurons naturally exhibit such heteroclinic networks of saddles, thereby providing a substrate for general analog computations. Several challenges need to be resolved before it becomes possible to effectively realize heteroclinic computing in hardware. The time scales on which computations are performed crucially depend on the switching times between saddles, which in turn are jointly controlled by the system's intrinsic dynamics and the level of external and measurement noise. The nonlinear dynamics of pulse-coupled systems often strongly deviate from that of time-continuously coupled (e.g., phase-coupled) systems. The factors impacting switching times in pulse-coupled systems are still not well understood. Here we systematically investigate switching times in dependence of the levels of noise and intrinsic dissipation in the system. We specifically reveal how local responses to pulses coact with external noise. Our findings confirm that, like in time-continuous phase-coupled systems, piecewise-continuous pulse-coupled systems exhibit switching times that transiently increase exponentially with the number of switches up to some order of magnitude set by the noise level. Complementarily, we show that switching times may constitute a good predictor for the computation reliability, indicating how often an input signal must be reiterated. By characterizing switching times between two saddles in conjunction with the reliability of a computation, our results provide a first step beyond the coding of input signal identities toward a complementary coding for the intensity of those signals. The results offer insights on how future heteroclinic computing systems may operate under natural, and thus noisy, conditions.
Methods and Costs to Achieve Ultra Reliable Life Support
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2012-01-01
A published Mars mission is used to explore the methods and costs to achieve ultra reliable life support. The Mars mission and its recycling life support design are described. The life support systems were made triply redundant, implying that each individual system will have fairly good reliability. Ultra reliable life support is needed for Mars and other long, distant missions. Current systems apparently have insufficient reliability. The life cycle cost of the Mars life support system is estimated. Reliability can be increased by improving the intrinsic system reliability, adding spare parts, or by providing technically diverse redundant systems. The costs of these approaches are estimated. Adding spares is least costly but may be defeated by common cause failures. Using two technically diverse systems is effective but doubles the life cycle cost. Achieving ultra reliability is worth its high cost because the penalty for failure is very high.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Chao-Yi; Hsieh, Ching-Heng; Lee, Ching-Wei
2015-02-02
ZrTiO{sub 4} crystallized in orthorhombic (o-) phase was stacked with an amorphous Yb{sub 2}O{sub 3} interfacial layer as the gate dielectric for Si-based p-MOSFETs. With thermal annealing after gate electrode, the gate stack with equivalent oxide thickness (EOT) of 0.82 nm achieves high dielectric quality by showing a low interface trap density (D{sub it}) of 2.75 × 10{sup 11 }cm{sup −2}eV{sup −1} near the midgap and low oxide traps. Crystallization of ZrTiO{sub 4} and post metal annealing are also proven to introduce very limited amount of metal induced gap states or interfacial dipole. The p-MOSFETs exhibit good sub-threshold swing of 75 mV/dec which is ascribedmore » to the low D{sub it} value and small EOT. Owing to the Y{sub 2}O{sub 3} interfacial layer and smooth interface with Si substrate that, respectively, suppress phonon and surface roughness scattering, the p-MOSFETs also display high hole mobility of 49 cm{sup 2}/V-s at 1 MV/cm. In addition, I{sub on}/I{sub off} ratio larger than 10{sup 6} is also observed. From the reliability evaluation by negative bias temperature instability test, after stressing with an electric field of −10 MV/cm at 85 °C for 1000 s, satisfactory threshold voltage shift of 12 mV and sub-threshold swing degradation of 3% were obtained. With these promising characteristics, the Yb{sub 2}O{sub 3}/o-ZrTiO{sub 4} gate stack holds the great potential for next-generation electronics.« less
Balogh, A L; Petak, F; Fodor, G H; Tolnai, J; Csorba, Z; Babik, B
2016-07-01
Capnography may provide useful non-invasive bedside information concerning heterogeneity in lung ventilation, ventilation-perfusion mismatching and metabolic status. Although the capnogram may be recorded by mainstream and sidestream techniques, the capnogram indices furnished by these approaches have not previously been compared systematically. Simultaneous mainstream and sidestream time and volumetric capnography was performed in anaesthetized, mechanically ventilated patients undergoing elective heart surgery. Time capnography was used to assess the phase II (SII,T) and III slopes (SIII,T). The volumetric method was applied to estimate phase II (SII,V) and III slopes (SIII,V), together with the dead space values according to the Fowler (VDF), Bohr (VDB), and Enghoff (VDE) methods and the volume of CO2 eliminated per breath ([Formula: see text]). The partial pressure of end-tidal CO2 ([Formula: see text]) was registered. Excellent correlation and good agreement were observed in SIII,T measured by the mainstream and sidestream techniques [ratio=1.05 (sem 0.16), R(2)=0.92, P<0.0001]. Although the sidestream technique significantly underestimated [Formula: see text] and overestimated SIII,V [1.32 (0.28), R(2)=0.93, P<0.0001], VDF, VDB, and VDE, the agreement between the mainstream and sidestream techniques in the difference between VDE and VDB, reflecting the intrapulmonary shunt, was excellent [0.97 (0.004), R(2)=0.92, P<0.0001]. The [Formula: see text] exhibited good correlation and mild differences between the mainstream and sidestream approaches [0.025 (0.005) kPa]. Sidestream capnography provides adequate quantitative bedside information about uneven alveolar emptying and ventilation-perfusion mismatching, because it allows reliable assessments of the phase III slope, [Formula: see text] and intrapulmonary shunt. Reliable measurement of volumetric parameters (phase II slope, dead spaces, and eliminated CO2 volumes) requires the application of a mainstream device. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Balogh, A. L.; Petak, F.; Fodor, G. H.; Tolnai, J.; Csorba, Z.; Babik, B.
2016-01-01
Background Capnography may provide useful non-invasive bedside information concerning heterogeneity in lung ventilation, ventilation–perfusion mismatching and metabolic status. Although the capnogram may be recorded by mainstream and sidestream techniques, the capnogram indices furnished by these approaches have not previously been compared systematically. Methods Simultaneous mainstream and sidestream time and volumetric capnography was performed in anaesthetized, mechanically ventilated patients undergoing elective heart surgery. Time capnography was used to assess the phase II (SII,T) and III slopes (SIII,T). The volumetric method was applied to estimate phase II (SII,V) and III slopes (SIII,V), together with the dead space values according to the Fowler (VDF), Bohr (VDB), and Enghoff (VDE) methods and the volume of CO2 eliminated per breath (VCO2). The partial pressure of end-tidal CO2 (PETCO2) was registered. Results Excellent correlation and good agreement were observed in SIII,T measured by the mainstream and sidestream techniques [ratio=1.05 (sem 0.16), R2=0.92, P<0.0001]. Although the sidestream technique significantly underestimated VCO2 and overestimated SIII,V [1.32 (0.28), R2=0.93, P<0.0001], VDF, VDB, and VDE, the agreement between the mainstream and sidestream techniques in the difference between VDE and VDB, reflecting the intrapulmonary shunt, was excellent [0.97 (0.004), R2=0.92, P<0.0001]. The PETCO2 exhibited good correlation and mild differences between the mainstream and sidestream approaches [0.025 (0.005) kPa]. Conclusions Sidestream capnography provides adequate quantitative bedside information about uneven alveolar emptying and ventilation–perfusion mismatching, because it allows reliable assessments of the phase III slope, PETCO2 and intrapulmonary shunt. Reliable measurement of volumetric parameters (phase II slope, dead spaces, and eliminated CO2 volumes) requires the application of a mainstream device. PMID:27317710
Reddy, Linda A; Dudek, Christopher M; Fabiano, Gregory A; Peters, Stephanie
2015-12-01
This article presents information about the construct validity and reliability of a new teacher self-report measure of classroom instructional and behavioral practices (the Classroom Strategies Scales-Teacher Form; CSS-T). The theoretical underpinnings and empirical basis for the instructional and behavioral management scales are presented. Information is provided about the construct validity, internal consistency, test-retest reliability, and freedom from item-bias of the scales. Given previous investigations with the CSS Observer Form, it was hypothesized that internal consistency would be adequate and that confirmatory factor analyses (CFA) of CSS-T data from 293 classrooms would offer empirical support for the CSS-T's Total, Composite and subscales, and yield a similar factor structure to that of the CSS Observer Form. Goodness-of-fit indices of χ2/df, Root Mean Square Error of Approximation, Goodness of Fit Index, and Adjusted Goodness of Fit Index suggested satisfactory fit of proposed CFA models whereas the Comparative Fit Index did not. Internal consistency estimates of .93 and .94 were obtained for the Instructional Strategies and Behavioral Strategies Total scales respectively. Adequate test-retest reliability was found for instructional and behavioral total scales (r = .79, r = .84, percent agreement 93% and 93%). The CSS-T evidences freedom from item bias on important teacher demographics (age, educational degree, and years of teaching experience). Implications of results are discussed. (c) 2015 APA, all rights reserved).
Validity and reliability of a novel measure of activity performance and participation.
Murgatroyd, Phil; Karimi, Leila
2016-01-01
To develop and evaluate an innovative clinician-rated measure, which produces global numerical ratings of activity performance and participation. Repeated measures study with 48 community-dwelling participants investigating clinical sensibility, comprehensiveness, practicality, inter-rater reliability, responsiveness, sensitivity and concurrent validity with Barthel Index. Important clinimetric characteristics including comprehensiveness and ease of use were rated >8/10 by clinicians. Inter-rater reliability was excellent on the summary scores (intraclass correlation of 0.95-0.98). There was good evidence that the new outcome measure distinguished between known high and low functional scoring groups, including both responsiveness to change and sensitivity at the same time point in numerous tests. Concurrent validity with the Barthel Index was fair to high (Spearman Rank Order Correlation 0.32-0.85, p > 0.05). The new measure's summary scores were nearly twice as responsive to change compared with the Barthel Index. Other more detailed data could also be generated by the new measure. The Activity Performance Measure is an innovative outcome instrument that showed good clinimetric qualities in this initial study. Some of the results were strong, given the sample size, and further trial and evaluation is appropriate. Implications for Rehabilitation The Activity Performance Measure is an innovative outcome measure covering activity performance and participation. In an initial evaluation, it showed good clinimetric qualities including responsiveness to change, sensitivity, practicality, clinical sensibility, item coverage, inter-rater reliability and concurrent validity with the Barthel Index. Further trial and evaluation is appropriate.
Takegami, Yasuhiko; Seki, Taisuke; Amano, Takafumi; Higuchi, Yoshitoshi; Komatsu, Daigo; Nishida, Yoshihiro; Ishiguro, Naoki
2017-08-01
Although many patients use the internet to access health-related information, the quality and the reliability of the information is highly inconsistent. Periacetabular osteotomy (PAO) is one of the surgical procedures for hip dysplasia. However, medical information on PAO is limited on the internet. This study aims to evaluate the quality and reliability of information available on PAO on the internet in Japan. A web search was conducted on two search engines for the following terms: "hip osteotomy," "pelvic osteotomy," and "osteotomy for hip preservation" in Japanese. In total, we found 120 websites. To determine the quality and reliability of information on each website, we used the Health on the Net Foundation (HON) score, the Brief DISCERN score, and an osteotomy-specific content (OSC) score. After eliminating duplicate websites, we reviewed 49 unique websites. Only three websites (6.1%) had good reliability, as indicated by their HON scores. Twelve websites (24.4%) had good-quality information, as measured by their Brief DISCERN scores. As evaluated by their OSC scores, physician websites were found to be biased toward etiology and surgical indication and did not provide information on the complications of procedures. Non-physician websites were generally insufficient. The information about PAO on the internet is, therefore, unreliable and of poor-quality for Japanese patients.
De la Torre, Gabriel G; Perez, Maria J; Ramallo, Miguel A; Randolph, Christopher; González-Villegas, Macarena Bernal
2016-04-01
In recent years, a number of studies focusing on the evaluation of neuropsychological deficits in individuals with schizophrenia have shown deficits that include several cognitive functions. Attention deficits as well as memory or executive function deficits are common in this kind of disorder together with sustained attention problems, working memory deficiencies, and problem-solving difficulties, among many others. Currently, the Repeatable Battery for the Assessment of Neuropsychological Status (RBANS) is gaining special importance in the evaluation of the cognitive deficits associated with schizophrenia. In this article, we describe an RBANS screening in a sample of 88 Spanish patients diagnosed with schizophrenia. We also aimed to check the battery's reliability, sensitivity, and specificity in the studied sample. We performed a comparative study with 88 healthy participants. The results showed a reliability index value of α = .795 and an item value of α = .762. For total test reliability, we obtained an index value of α = .761 and an item value of α = .762. Sensitivity score was 87.5% and specificity 86.4%. RBANS obtained good reliability, sensitivity, and specificity scores and represents a good screening tool in detecting cognitive deficits associated with schizophrenia. © The Author(s) 2015.
Reliability and validity of the Microsoft Kinect for evaluating static foot posture
2013-01-01
Background The evaluation of foot posture in a clinical setting is useful to screen for potential injury, however disagreement remains as to which method has the greatest clinical utility. An inexpensive and widely available imaging system, the Microsoft Kinect™, may possess the characteristics to objectively evaluate static foot posture in a clinical setting with high accuracy. The aim of this study was to assess the intra-rater reliability and validity of this system for assessing static foot posture. Methods Three measures were used to assess static foot posture; traditional visual observation using the Foot Posture Index (FPI), a 3D motion analysis (3DMA) system and software designed to collect and analyse image and depth data from the Kinect. Spearman’s rho was used to assess intra-rater reliability and concurrent validity of the Kinect to evaluate foot posture, and a linear regression was used to examine the ability of the Kinect to predict total visual FPI score. Results The Kinect demonstrated moderate to good intra-rater reliability for four FPI items of foot posture (ρ = 0.62 to 0.78) and moderate to good correlations with the 3DMA system for four items of foot posture (ρ = 0.51 to 0.85). In contrast, intra-rater reliability of visual FPI items was poor to moderate (ρ = 0.17 to 0.63), and correlations with the Kinect and 3DMA systems were poor (absolute ρ = 0.01 to 0.44). Kinect FPI items with moderate to good reliability predicted 61% of the variance in total visual FPI score. Conclusions The majority of the foot posture items derived using the Kinect were more reliable than the traditional visual assessment of FPI, and were valid when compared to a 3DMA system. Individual foot posture items recorded using the Kinect were also shown to predict a moderate degree of variance in the total visual FPI score. Combined, these results support the future potential of the Kinect to accurately evaluate static foot posture in a clinical setting. PMID:23566934
NASA Astrophysics Data System (ADS)
Namburi, Devendra K.; Shi, Yunhua; Palmer, Kysen G.; Dennis, Anthony R.; Durrell, John H.; Cardwell, David A.
2016-09-01
A fundamental requirement of the fabrication of high performing, (RE)-Ba-Cu-O bulk superconductors is achieving a single grain microstructure that exhibits good flux pinning properties. The top seeded melt growth (TSMG) process is a well-established technique for the fabrication of single grain (RE)BCO bulk samples and is now applied routinely by a number of research groups around the world. The introduction of a buffer layer to the TSMG process has been demonstrated recently to improve significantly the general reliability of the process. However, a number of growth-related defects, such as porosity and the formation of micro-cracks, remain inherent to the TSMG process, and are proving difficult to eliminate by varying the melt process parameters. The seeded infiltration and growth (SIG) process has been shown to yield single grain samples that exhibit significantly improved microstructures compared to the TSMG technique. Unfortunately, however, SIG leads to other processing challenges, such as the reliability of fabrication, optimisation of RE2BaCuO5 (RE-211) inclusions (size and content) in the sample microstructure, practical oxygenation of as processed samples and, hence, optimisation of the superconducting properties of the bulk single grain. In the present paper, we report the development of a near-net shaping technique based on a novel two-step, buffer-aided top seeded infiltration and growth (BA-TSIG) process, which has been demonstrated to improve greatly the reliability of the single grain growth process and has been used to fabricate successfully bulk, single grain (RE)BCO superconductors with improved microstructures and superconducting properties. A trapped field of ˜0.84 T and a zero field current density of 60 kA cm-2 have been measured at 77 K in a bulk, YBCO single grain sample of diameter 25 mm processed by this two-step BA-TSIG technique. To the best of our knowledge, this value of trapped field is the highest value ever reported for a sample fabricated by an infiltration and growth process. In this study we report the successful fabrication of 14 YBCO samples, with diameters of up to 32 mm, by this novel technique with a success rate of greater than 92%.
Quantifying similarity in reliability surfaces using the probability of agreement
Stevens, Nathaniel T.; Anderson-Cook, Christine Michaela
2017-03-30
When separate populations exhibit similar reliability as a function of multiple explanatory variables, combining them into a single population is tempting. This can simplify future predictions and reduce uncertainty associated with estimation. However, combining these populations may introduce bias if the underlying relationships are in fact different. The probability of agreement formally and intuitively quantifies the similarity of estimated reliability surfaces across a two-factor input space. An example from the reliability literature demonstrates the utility of the approach when deciding whether to combine two populations or to keep them as distinct. As a result, new graphical summaries provide strategies formore » visualizing the results.« less
Quantifying similarity in reliability surfaces using the probability of agreement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stevens, Nathaniel T.; Anderson-Cook, Christine Michaela
When separate populations exhibit similar reliability as a function of multiple explanatory variables, combining them into a single population is tempting. This can simplify future predictions and reduce uncertainty associated with estimation. However, combining these populations may introduce bias if the underlying relationships are in fact different. The probability of agreement formally and intuitively quantifies the similarity of estimated reliability surfaces across a two-factor input space. An example from the reliability literature demonstrates the utility of the approach when deciding whether to combine two populations or to keep them as distinct. As a result, new graphical summaries provide strategies formore » visualizing the results.« less
ERIC Educational Resources Information Center
Woodburn, Jim; Sutcliffe, Nick
1996-01-01
The Objective Structured Clinical Examination (OSCE), initially developed for undergraduate medical education, has been adapted for assessment of clinical skills in podiatry students. A 12-month pilot study found the test had relatively low levels of reliability, high construct and criterion validity, and good stability of performance over time.…
ERIC Educational Resources Information Center
Horon, Robert; McManus, Todd; Schmollinger, Justine; Barr, Tiffany; Jimenez, Megan
2013-01-01
The reliability, validity, and utility of the Adult Suicidal Ideation Questionnaire (ASIQ), Beck Hopelessness Scale (BHS), Beck Scale for Suicide Ideation (BSS), and Reasons for Attempting Suicide Questionnaire (RASQ) with correctional mental health populations was evaluated. Evidence was found indicating good to excellent reliability for all…
Transferable Competences of Young People with a High Dropout Risk in Vocational Training in Germany
ERIC Educational Resources Information Center
Frey, Andreas; Balzer, Lars; Ruppert, Jean-Jacques
2014-01-01
This paper examines whether the subjective beliefs on their competences of 409 trainees in machinery, sales, and logistics constitute a reliable and valid way to measure transferable competences. The analysis of results attributes satisfactory to good reliability values to the assessment procedure. Furthermore, it could be shown that young people…
Ishman, Stacey L; Benke, James R; Johnson, Kaalan Erik; Zur, Karen B; Jacobs, Ian N; Thorne, Marc C; Brown, David J; Lin, Sandra Y; Bhatti, Nasir; Deutsch, Ellen S
2012-10-01
OBJECTIVES To confirm interrater reliability using blinded evaluation of a skills-assessment instrument to assess the surgical performance of resident and fellow trainees performing pediatric direct laryngoscopy and rigid bronchoscopy in simulated models. DESIGN Prospective, paired, blinded observational validation study. SUBJECTS Paired observers from multiple institutions simultaneously evaluated residents and fellows who were performing surgery in an animal laboratory or using high-fidelity manikins. The evaluators had no previous affiliation with the residents and fellows and did not know their year of training. INTERVENTIONS One- and 2-page versions of an objective structured assessment of technical skills (OSATS) assessment instrument composed of global and a task-specific surgical items were used to evaluate surgical performance. RESULTS Fifty-two evaluations were completed by 17 attending evaluators. The instrument agreement for the 2-page assessment was 71.4% when measured as a binary variable (ie, competent vs not competent) (κ = 0.38; P = .08). Evaluation as a continuous variable revealed a 42.9% percentage agreement (κ = 0.18; P = .14). The intraclass correlation was 0.53, considered substantial/good interrater reliability (69% reliable). For the 1-page instrument, agreement was 77.4% when measured as a binary variable (κ = 0.53, P = .0015). Agreement when evaluated as a continuous measure was 71.0% (κ = 0.54, P < .001). The intraclass correlation was 0.73, considered high interrater reliability (85% reliable). CONCLUSIONS The OSATS assessment instrument is an effective tool for evaluating surgical performance among trainees with acceptable interrater reliability in a simulator setting. Reliability was good for both the 1- and 2-page OSATS checklists, and both serve as excellent tools to provide immediate formative feedback on operational competency.
Ahlqvist, Margary; Berglund, Britta; Nordström, Gun; Klang, Birgitta; Johansson, Eva
2014-01-01
Nursing students should be given opportunities to participate in clinical audits during their education. However, audit tools are seldom tested for reliability among nursing students. The aim of this study was to present reliability among nursing students using the instrument PVC assess to assess management of peripheral venous catheters (PVCs) and PVC-related signs of thrombophlebitis. PVC assess was used to assess 67 inserted PVCs in 60 patients at ten wards at a university hospital. One group of nursing students (n=4) assessed PVCs at the bedside (inter-rater reliability) and photographs of these PVCs were taken. Another group of students (n=3) assessed the PVCs in the photographs after 4 weeks (test-retest reliability). To determine reliability, proportion of agreement [P(A)] and Cohen's kappa coefficient (κ) were calculated. For bedside assessment of PVCs, P(A) ranged from good to excellent (0.80-1.0) in 55% of the 26 PVC assess items that were tested. P(A) was poor (<0.70) for two items: "adherence of inner dressing to the skin" and "PVC location." In 81% of the items, κ was between moderate and almost perfect: moderate (n=5), substantial (n=3), almost perfect (n=5). For edema at insertion site and two items on PVC dressing, κ was fair (0.21-0.40). Regarding test-retest reliability, P(A) varied between good and excellent (0.81-1) in 85%-95% of the items, and the κ ranged between moderate and almost perfect (0.41-1) in 90%-95%. PVC assess demonstrated satisfactory reliability among nursing students. However, students need training in how to use the instrument before assessing PVCs.
Bowman, Gene L.; Shannon, Jackilen; Ho, Emily; Traber, Maret G.; Frei, Balz; Oken, Barry S.; Kaye, Jeffery A.; Quinn, Joseph F.
2010-01-01
Introduction There is great interest in nutritional strategies for the prevention of age-related cognitive decline, yet the best methods for nutritional assessment in populations at risk for dementia are still evolving. Our study objective was to test the reliability and validity of two common nutritional assessments (plasma nutrient biomarkers and Food Frequency Questionnaire) in people at risk for dementia. Methods Thirty-eight elders, half with amnestic -Mild Cognitive Impairment and half with intact cognition were recruited. Nutritional assessments were collected together at baseline and again at 1 month. Intraclass and Pearson correlation coefficients quantified reliability and validity. Results Twenty-six nutrients were examined and reliability was very good or better for 77% (20/26, ICC ≥ .75) of the plasma nutrient biomarkers and for 88% of the FFQ estimates. Twelve of the plasma nutrient estimates were as reliable as the commonly measured plasma cholesterol (ICC=.92). FFQ and plasma long-chain fatty acids (docosahexaenoic acid, r =.39, eicosapentaenoic acid, r = .39) and carotenoids (α-carotene, r =.49; lutein + zeaxanthin, r = .48; β-carotene, r = .43; β-cryptoxanthin, r = .41) were correlated, but no other FFQ estimates correlated with respective nutrient biomarkers. Correlations between FFQ and plasma fatty acids and carotenoids were significantly stronger after removing subjects with MCI. Conclusion The reliability and validity of plasma and FFQ nutrient estimates vary according to the nutrient of interest. Memory deficit attenuates FFQ estimate validity and inflates FFQ estimate reliability. Many plasma nutrient biomarkers have very good reliability over 1-month regardless of memory state. This method can circumvent sources of error seen in other less direct methods of nutritional assessment. PMID:20856100
Apivatgaroon, Adinun; Angthong, Chayanin; Sanguanjit, Prakasit; Chernchujit, Bancha
2016-10-01
To develop a Thai version of the Kujala score and show the evaluation of the validity and reliability of the score. The Thai version of the Kujala score was developed using the forward-backward translation protocol. The 49 PFPS patients answered the Thai version of questionnaires including the Kujala score, Short Form-36 (SF-36) and International Knee Documentation Committee (IKDC) Subjective Knee Form. The validity between the scores has been tested. The reliability was assessed using test-retest reliability and internal consistency. The Thai version of the Kujala score showed a good correlation with Thai IKDC Subjective Knee Form (Pearson's correlation coefficient; r = 0.74: p < 0.01) and moderate correlation with the Thai SF-36 subscales of physical component summary, total score and role physical (r = 0.586, 0.571 and 0.524, respectively: p < 0.01). The test-retest reliability was excellent with an intra-class correlation coefficient of 0.908 (p < 0.001; 95% CI [0.842-0.947]). The internal consistency was strong with Cronbach's alpha of 0.952 (p < 0.001). No floor and ceiling effects were observed. The Thai version of the Kujala score has shown good validity and reliability. This score can be effectively used for evaluating Thai patients with patellofemoral pain syndrome. Implications for Rehabilitation The Kujala score is a self-administered questionnaire for patients with patellofemoral pain syndrome (PFPS). The validity and reliability of the Thai version of Kujala are compatible with other versions (Turkish, Chinese and Persian version). The Thai version of Kujala has been shown to have validity and reliability in Thai PFPS patients and can be used for clinical evaluation and also in the research work.
Charlton, Paula C; Mentiplay, Benjamin F; Grimaldi, Alison; Pua, Yong-Hao; Clark, Ross A
2017-02-01
Firstly to describe the reliability of assessing maximal isometric strength of the hip abductor and adductor musculature using a hand held dynamometry (HHD) protocol with simultaneous wireless surface electromyographic (sEMG) evaluation of the gluteus medius (GM) and adductor longus (AL). Secondly, to describe the correlation between isometric strength recorded with the HHD protocol and a laboratory standard isokinetic device. Reliability and correlational study. A sample of 24 elite, male, junior, rugby league athletes, age 16-20 years participated in repeated HHD and isometric Kin-Com (KC) strength testing with simultaneous sEMG assessment, on average (range) 6 (5-7) days apart by a single assessor. Strength tests included; unilateral hip abduction (ABD) and adduction (ADD) and bilateral ADD assessed with squeeze (SQ) tests in 0 and 45° of hip flexion. HHD demonstrated good to excellent inter-session reliability for all outcome measures (ICC (2,1) =0.76-0.91) and good to excellent association with the laboratory reference KC (ICC (2,1) =0.80-0.88). Whilst intra-session, inter-trial reliability of EMG activation and co-activation outcome measures ranged from moderate to excellent (ICC (2,1) =0.70-0.94), inter-session reliability was poor (all ICC (2,1) <0.50). Isometric strength testing of the hip ABD and ADD musculature using HHD may be measured reliably in elite, junior rugby league athletes. Due to the poor inter-session reliability of sEMG measures, it is not recommended for athlete screening purposes if using the techniques implemented in this study. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Maki, Dana; Rajab, Ebrahim; Watson, Paul J; Critchley, Duncan J
2014-12-01
Cross-cultural translation, adaptation, and psychometric testing. To cross-culturally translate and adapt the Roland-Morris Disability Questionnaire (RMDQ) into Modern Standard Arabic and examine its validity with Arabic-speaking patients with low back pain (LBP). The English RMDQ is valid, reliable, and commonly used to assess LBP disability in clinical practice and research. There is no valid and reliable version of the RMDQ in Modern Standard Arabic. The RMDQ was forward translated and back translated. An expert committee of musculoskeletal physiotherapists reviewed the translation. Eight patients with LBP evaluated item-by-item comprehensibility. Ten patients piloted the RMDQ for overall comprehensibility and acceptability. Seventeen bilingual patients tested the agreement of the Arabic and English RMDQs. Two-hundred one patients completed the RMDQ and the visual analogue scale. Sixty-four patients were followed-up for test-retest reliability. Translation of most items was uncontroversial. The expert committee found the Arabic RMDQ clinically and culturally appropriate. They reviewed item 11, addressing bending and kneeling, because this has a clinical significance and cultural/religious implication regarding prayer positions. All patients reported that it was easy to understand and complete. The Arabic RMDQ had high overall agreement with the English RMDQ for the global score (intraclass correlation coefficient [ICC] = 0.925; 0.811-0.972). Kappa statistics showed good item-by-item agreement (none ≤0.30). Mean (SD) RMDQ and visual analog scale scores of 201 patients were 10.53 (4.80) and 5.11 (2.28), respectively. The RMDQ had a low correlation against pain intensity (r = 0.259; P < 0.01). A Cronbach α of 0.729 showed high internal consistency. Test-retest reliability of the Arabic RMDQ was good (ICC = 0.900; 95% confidence interval, 0.753-0.951). Kappa statistics were high for 18 items and fair for 6. The Arabic version of the RMDQ has good comprehensibility and acceptability, high internal consistency and reliability, low correlation against pain intensity, and good agreement with the English RMDQ. We recommend its use with Arabic-speaking patients with LBP. 3.
Development and validation of PediaTrac™: A web-based tool to track developing infants.
Lajiness-O'Neill, Renée; Brooks, Judith; Lukomski, Angela; Schilling, Stephen; Huth-Bocks, Alissa; Warschausky, Seth; Flores, Ana-Mercedes; Swick, Casey; Nyman, Tristin; Andersen, Tiffany; Morris, Natalie; Schmitt, Thomas A; Bell-Smith, Jennifer; Moir, Barbara; Hodges, Elise K; Lyddy, James E
2018-02-01
PediaTrac™, a 363-item web-based tool to track infant development, administered in modules of ∼40-items per sampling period, newborn (NB), 2--, 4--, 6--, 9-- and 12--months was validated. Caregivers answered demographic, medical, and environmental questions, and questions covering the sensorimotor, feeding/eating, sleep, speech/language, cognition, social-emotional, and attachment domains. Expert Panel Reviews and Cognitive Interviews (CI) were conducted to validate the item bank. Classical Test Theory (CTT) and Item Response Theory (IRT) methods were employed to examine the dimensionality and psychometric properties of PediaTrac with pooled longitudinal and cross-sectional cohorts (N = 132). Intraclass correlation coefficients (ICC) for the Expert Panel Review revealed moderate agreement at 6 -months and good reliability at other sampling periods. ICC estimates for CI revealed moderate reliability regarding clarity of the items at NB and 4 months, good reliability at 2--, 9-- and 12--months and excellent reliability at 6 -months. CTT revealed good coefficient alpha estimates (α ≥ 0.77 for five of the six ages) for the Social-Emotional/Communication, Attachment (α ≥ 0.89 for all ages), and Sensorimotor (α ≥ 0.75 at 6-months) domains, revealing the need for better targeting of sensorimotor items. IRT modeling revealed good reliability (r = 0.85-0.95) for three distinct domains (Feeding/Eating, Social-Emotional/Communication and Attachment) and four subdomains (Feeding Breast/Formula, Feeding Solid Food, Social-Emotional Information Processing, Communication/Cognition). Convergent and discriminant construct validity were demonstrated between our IRT-modeled domains and constructs derived from existing developmental, behavioral and caregiver measures. Our Attachment domain was significantly correlated with existing measures at the NB and 2-month periods, while the Social-Emotional/Communication domain was highly correlated with similar constructs at the 6-, 9- and 12-month periods. PediaTrac has potential for producing novel and effective estimates of infant development via the Sensorimotor, Feeding/Eating, Social-Emotional/Communication and Attachment domains. Copyright © 2018 Elsevier Inc. All rights reserved.
Décary, Simon; Ouellet, Philippe; Vendittoli, Pascal-André; Desmeules, François
2016-12-01
Clinicians often rely on physical examination tests to guide them in the diagnostic process of knee disorders. However, reliability of these tests is often overlooked and may influence the consistency of results and overall diagnostic validity. Therefore, the objective of this study was to systematically review evidence on the reliability of physical examination tests for the diagnosis of knee disorders. A structured literature search was conducted in databases up to January 2016. Included studies needed to report reliability measures of at least one physical test for any knee disorder. Methodological quality was evaluated using the QAREL checklist. A qualitative synthesis of the evidence was performed. Thirty-three studies were included with a mean QAREL score of 5.5 ± 0.5. Based on low to moderate quality evidence, the Thessaly test for meniscal injuries reached moderate inter-rater reliability (k = 0.54). Based on moderate to excellent quality evidence, the Lachman for anterior cruciate ligament injuries reached moderate to excellent inter-rater reliability (k = 0.42 to 0.81). Based on low to moderate quality evidence, the Tibiofemoral Crepitus, Joint Line and Patellofemoral Pain/Tenderness, Bony Enlargement and Joint Pain on Movement tests for knee osteoarthritis reached fair to excellent inter-rater reliability (k = 0.29 to 0.93). Based on low to moderate quality evidence, the Lateral Glide, Lateral Tilt, Lateral Pull and Quality of Movement tests for patellofemoral pain reached moderate to good inter-rater reliability (k = 0.49 to 0.73). Many physical tests appear to reach good inter-rater reliability, but this is based on low-quality and conflicting evidence. High-quality research is required to evaluate the reliability of knee physical examination tests. Copyright © 2016 Elsevier Ltd. All rights reserved.
Tabard-Fougère, Anne; Bonnefoy-Mazure, Alice; Hanquinet, Sylviane; Lascombes, Pierre; Armand, Stéphane; Dayer, Romain
2017-01-15
Test-retest study. This study aimed to evaluate the validity and reliability of rasterstereography in patients with adolescent idiopathic scoliosis (AIS) with a major curve Cobb angle (CA) between 10° and 40° for frontal, sagittal, and transverse parameters. Previous studies evaluating the validity and reliability of rasterstereography concluded that this technique had good accuracy compared with radiographs and a high intra- and interday reliability in healthy volunteers. To the best of our knowledge, the validity and reliability have not been assessed in AIS patients. Thirty-five adolescents with AIS (male = 13) aged 13.1 ± 2.0 years were included. To evaluate the validity of the scoliosis angle (SA) provided by rasterstereography, a comparison (t test, Pearson correlation) was performed with the CA obtained using 2D EOS® radiography (XR). Three rasterstereographic repeated measurements were independently performed by two operators on the same day (interrater reliability) and again by the first operator 1 week later (intrarater reliability). The variables of interest were the SA, lumbar lordosis, and thoracic kyphosis angle, trunk length, pelvic obliquity, and maximum, root mean square and amplitude of vertebral rotations. The data analyses used intraclass correlation coefficients (ICCs). The CA and SA were strongly correlated (R = 0.70) and were nonsignificantly different (P = 0.60). The intrarater reliability (same day: ICC [1, 1], n = 35; 1 week later: ICC [1, 3], n = 28) and interrater reliability (ICC [3, 3], n = 16) were globally excellent (ICC > 0.75) except for the assessment of pelvic obliquity. This study showed that the rasterstereographic system allows for the evaluation of AIS patients with a good validity compared with XR with an overall excellent intra- and interrater reliability. Based on these results, this automatic, fast, and noninvasive system can be used for monitoring the evolution of AIS in growing patients instead of repetitive radiographs, thereby reducing radiation exposure and decreasing costs. 4.
Tkachenko, Pavlo; Kriukova, Galyna; Aleksandrova, Marharyta; Chertov, Oleg; Renard, Eric; Pereverzyev, Sergei V
2016-10-01
Nocturnal hypoglycemia (NH) is common in patients with insulin-treated diabetes. Despite the risk associated with NH, there are only a few methods aiming at the prediction of such events based on intermittent blood glucose monitoring data and none has been validated for clinical use. Here we propose a method of combining several predictors into a new one that will perform at the level of the best involved one, or even outperform all individual candidates. The idea of the method is to use a recently developed strategy for aggregating ranking algorithms. The method has been calibrated and tested on data extracted from clinical trials, performed in the European FP7-funded project DIAdvisor. Then we have tested the proposed approach on other datasets to show the portability of the method. This feature of the method allows its simple implementation in the form of a diabetic smartphone app. On the considered datasets the proposed approach exhibits good performance in terms of sensitivity, specificity and predictive values. Moreover, the resulting predictor automatically performs at the level of the best involved method or even outperforms it. We propose a strategy for a combination of NH predictors that leads to a method exhibiting a reliable performance and the potential for everyday use by any patient who performs self-monitoring of blood glucose. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Jiang, Hu; Li, Xiangmin; Xiong, Ying; Pei, Ke; Nie, Lijuan; Xiong, Yonghua
2017-02-28
A silver nanoparticle (AgNP)-based fluorescence-quenching lateral flow immunoassay with competitive format (cLFIA) was developed for sensitive detection of ochratoxin A (OTA) in grape juice and wine samples in the present study. The Ru(phen) 3 2 + -doped silica nanoparticles (RuNPs) were sprayed on the test and control line zones as background fluorescence signals. The AgNPs were designed as the fluorescence quenchers of RuNPs because they can block the exciting light transferring to the RuNP molecules. The proposed method exhibited high sensitivity for OTA detection, with a detection limit of 0.06 µg/L under optimized conditions. The method also exhibited a good linear range for OTA quantitative analysis from 0.08 µg/L to 5.0 µg/L. The reliability of the fluorescence-quenching cLFIA method was evaluated through analysis of the OTA-spiked red grape wine and juice samples. The average recoveries ranged from 88.0% to 110.0% in red grape wine and from 92.0% to 110.0% in grape juice. Meanwhile, less than a 10% coefficient variation indicated an acceptable precision of the cLFIA method. In summary, the new AgNP-based fluorescence-quenching cLFIA is a simple, rapid, sensitive, and accurate method for quantitative detection of OTA in grape juice and wine or other foodstuffs.
Jiang, Hu; Li, Xiangmin; Xiong, Ying; Pei, Ke; Nie, Lijuan; Xiong, Yonghua
2017-01-01
A silver nanoparticle (AgNP)-based fluorescence-quenching lateral flow immunoassay with competitive format (cLFIA) was developed for sensitive detection of ochratoxin A (OTA) in grape juice and wine samples in the present study. The Ru(phen)32+-doped silica nanoparticles (RuNPs) were sprayed on the test and control line zones as background fluorescence signals. The AgNPs were designed as the fluorescence quenchers of RuNPs because they can block the exciting light transferring to the RuNP molecules. The proposed method exhibited high sensitivity for OTA detection, with a detection limit of 0.06 µg/L under optimized conditions. The method also exhibited a good linear range for OTA quantitative analysis from 0.08 µg/L to 5.0 µg/L. The reliability of the fluorescence-quenching cLFIA method was evaluated through analysis of the OTA-spiked red grape wine and juice samples. The average recoveries ranged from 88.0% to 110.0% in red grape wine and from 92.0% to 110.0% in grape juice. Meanwhile, less than a 10% coefficient variation indicated an acceptable precision of the cLFIA method. In summary, the new AgNP-based fluorescence-quenching cLFIA is a simple, rapid, sensitive, and accurate method for quantitative detection of OTA in grape juice and wine or other foodstuffs. PMID:28264472
Lee, Ke-Jing; Chang, Yu-Chi; Lee, Cheng-Jung; Wang, Li-Wen; Wang, Yeong-Her
2017-01-01
A one-transistor and one-resistor (1T1R) architecture with a resistive random access memory (RRAM) cell connected to an organic thin-film transistor (OTFT) device is successfully demonstrated to avoid the cross-talk issues of only one RRAM cell. The OTFT device, which uses barium zirconate nickelate (BZN) as a dielectric layer, exhibits favorable electrical properties, such as a high field-effect mobility of 2.5 cm2/Vs, low threshold voltage of −2.8 V, and low leakage current of 10−12 A, for a driver in the 1T1R operation scheme. The 1T1R architecture with a TiO2-based RRAM cell connected with a BZN OTFT device indicates a low operation current (10 μA) and reliable data retention (over ten years). This favorable performance of the 1T1R device can be attributed to the additional barrier heights introduced by using Ni (II) acetylacetone as a substitute for acetylacetone, and the relatively low leakage current of a BZN dielectric layer. The proposed 1T1R device with low leakage current OTFT and excellent uniform resistance distribution of RRAM exhibits a good potential for use in practical low-power electronic applications. PMID:29232828
Inkjet 3D printing of UV and thermal cure silicone elastomers for dielectric elastomer actuators
NASA Astrophysics Data System (ADS)
McCoul, David; Rosset, Samuel; Schlatter, Samuel; Shea, Herbert
2017-12-01
Dielectric elastomer actuators (DEAs) are an attractive form of electromechanical transducer, possessing high energy densities, an efficient design, mechanical compliance, high speed, and noiseless operation. They have been incorporated into a wide variety of devices, such as microfluidic systems, cell bioreactors, tunable optics, haptic displays, and actuators for soft robotics. Fabrication of DEA devices is complex, and the majority are inefficiently made by hand. 3D printing offers an automated and flexible manufacturing alternative that can fabricate complex, multi-material, integrated devices consistently and in high resolution. We present a novel additive manufacturing approach to DEA devices in which five commercially available, thermal and UV-cure DEA silicone rubber materials have been 3D printed with a drop-on-demand, piezoelectric inkjet system. Using this process, 3D structures and high-quality silicone dielectric elastomer membranes as thin as 2 μm have been printed that exhibit mechanical and actuation performance at least as good as conventionally blade-cast membranes. Printed silicone membranes exhibited maximum tensile strains of up to 727%, and DEAs with printed silicone dielectrics were actuated up to 6.1% area strain at a breakdown strength of 84 V μm-1 and also up to 130 V μm-1 at 2.4% strain. This approach holds great potential to manufacture reliable, high-performance DEA devices with high throughput.
Jeong, Ju Ri; Ko, Young Jun; Ha, Hyun Geun; Lee, Wan Hee
2016-03-01
This study was to establish inter-rater and intrarater reliability of the rehabilitative ultrasonographic imaging (RUSI) technique for muscle thickness measurement of the rhomboid major at rest and with the shoulder abducted to 90°. Twenty-four young adults (eight men, 16 women; right-handed; mean age [±SD], 24·4 years [±2·6]) with no history of neck, shoulder, or arm pain were recruited. Rhomboid major muscle images were obtained in the resting position and with shoulder in 90° abduction using an ultrasonography system with a 7·5-MHz linear transducer. In these two positions, the examiners found the site at which the transducer could be placed. Two examiners obtained the images of all participants in three test sessions at random. Intraclass correlation coefficients (ICC) were used to estimate reliability. All ICCs (95% CI) were >0·75, ranging from 0·93 to 0·98, which indicates good reliability. The ICCs for inter-rater reliability ranged from 0·75 to 0·94. For the absolute value of the difference in the intra-examiner reliability between the right and left ratios, the ICCs ranged from 0·58 to 0·91. In this study, the intra- and interexaminer reliability of muscle thickness measurements of the rhomboid major were good. Therefore, we suggest that muscle thickness measurements of the rhomboid major obtained with the RUSI technique would be useful for clinical rehabilitative assessment. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Abma, Femke I; van der Klink, Jac J L; Bültmann, Ute
2013-03-01
The promotion of a sustainable, healthy and productive working life attracts more and more attention. Recently the Work Role Functioning Questionnaire (WRFQ) has been cross-culturally translated and adapted to Dutch. This questionnaire aims to measure the health-related work functioning of workers with health problems. The aim of this study is to evaluate the reliability, validity (including five new items) and responsiveness of the WRFQ 2.0 in the working population. A longitudinal study was conducted among workers. The reliability (internal consistency, test-retest reliability, measurement error), validity (structural validity-factor analysis, construct validity by means of hypotheses testing) and responsiveness of the WRFQ 2.0 were evaluated. A total of N = 553 workers completed the survey. The final WRFQ 2.0 has four subscales and showed very good internal consistency, moderate test-retest reliability, good construct validity and moderate responsiveness in the working population. The WRFQ was able to distinguish between groups with different levels of mental health, physical health, fatigue and need for recovery. A moderate correlation was found between WRFQ and related constructs respectively work ability and work productivity. A weak relationship was found with general self-rated health, work engagement and work involvement. The WRFQ 2.0 is a reliable and valid instrument to measure health-related work functioning in the working population. Further validation in larger samples is recommended, especially for test-retest reliability, responsiveness and the questionnaire's ability to predict the future course of health-related work functioning.
[Reliability and validity of Meaningful Life Measure-Chinese Revised in Chinese college students].
Xiao, Rong; Lai, Qiao-Zhen; Yang, Jia-Ping
2016-04-20
To test the reliability and validity of Meaningful Life Measure-Chinese Revised (MLM-CR) in Chinese college students. A total of 1035 college students were evaluated with MLM-CR, Satisfaction with Life Scale (SWLS), Purpose in Life (PIL) and Patient Health Questionnaire-2 (PHQ-2), and 120 of the students were examined with PIL-SF twice. All the items in MLM-CR had good discrimination indexes (r=0.753-0.838, P<0.001). Confirmatory factor analysis confirmed the hypothesized five-factor model of MLM-CR (Χ 2 /df=3.4, GFI=0.946, AGFI=0.924, RMR=0.069, NFI=0.953, CFI=0.966, RMSEA=0.048). The total internal consistency reliability of MLM-CR was 0.942, and the alpha coefficients of the 5 dimensions ranged from 0.782 to 0.877; the total split-half reliability was 0.920, and the split-half reliability of the 5 dimensions ranged from 0.752 to 0.830; the total test-retest reliability was 0.871, and the test-retest reliability of the 5 dimensions ranged from 0.783 to 0.805. The criterion validity of MLM-CR in correlation with SWLS, PIL and PHQ-2 was 0.66, 0.755 and -0.388, respectively (P<0.01). The Average score of MLM-CR of the college students was 5.20∓0.90, and the scores were significantly higher in female students than in the male students (P<0.001). MLM-CR has good psychometric properties for application in comprehensive evaluation of personal meaning in life.
The long-term reliability of static and dynamic quantitative sensory testing in healthy individuals.
Marcuzzi, Anna; Wrigley, Paul J; Dean, Catherine M; Adams, Roger; Hush, Julia M
2017-07-01
Quantitative sensory tests (QSTs) have been increasingly used to investigate alterations in somatosensory function in a wide range of painful conditions. The interpretation of these findings is based on the assumption that the measures are stable and reproducible. To date, reliability of QST has been investigated for short test-retest intervals. The aim of this study was to investigate the long-term reliability of a multimodal QST assessment in healthy people, with testing conducted on 3 occasions over 4 months. Forty-two healthy people were enrolled in the study. Static and dynamic tests were performed, including cold and heat pain threshold (CPT, HPT), mechanical wind-up [wind-up ratio (WUR)], pressure pain threshold (PPT), 2-point discrimination (TPD), and conditioned pain modulation (CPM). Systematic bias, relative reliability and agreement were analysed using repeated measure analysis of variance, intraclass correlation coefficients (ICCs3,1) and SE of the measurement (SEM), respectively. Static QST (CPT, HPT, PPT, and TPD) showed good-to-excellent reliability (ICCs: 0.68-0.90). Dynamic QST (WUR and CPM) showed poor-to-good reliability (ICCs: 0.35-0.61). A significant linear decrease over time was observed for mechanical QST at the back (PPT and TPD) and for CPM (P < 0.01). Static QST were stable over a period of 4 months; however, a small systematic decrease over time has been observed for mechanical QST. Dynamic QST showed considerable variability over time; in particular, CPM using PPT as the test stimulus did not show adequate reliability, suggesting that this test paradigm may be less useful for monitoring individuals over time.
Reliability and Validity of Dual-Task Mobility Assessments in People with Chronic Stroke
Yang, Lei; He, Chengqi; Pang, Marco Yiu Chung
2016-01-01
Background The ability to perform a cognitive task while walking simultaneously (dual-tasking) is important in real life. However, the psychometric properties of dual-task walking tests have not been well established in stroke. Objective To assess the test-retest reliability, concurrent and known-groups validity of various dual-task walking tests in people with chronic stroke. Design Observational measurement study with a test-retest design. Methods Eighty-eight individuals with chronic stroke participated. The testing protocol involved four walking tasks (walking forward at self-selected and maximal speed, walking backward at self-selected speed, and crossing over obstacles) performed simultaneously with each of the three attention-demanding tasks (verbal fluency, serial 3 subtractions or carrying a cup of water). For each dual-task condition, the time taken to complete the walking task, the correct response rate (CRR) of the cognitive task, and the dual-task effect (DTE) for the walking time and CRR were calculated. Forty-six of the participants were tested twice within 3–4 days to establish test-retest reliability. Results The walking time in various dual-task assessments demonstrated good to excellent reliability [Intraclass correlation coefficient (ICC2,1) = 0.70–0.93; relative minimal detectable change at 95% confidence level (MDC95%) = 29%-45%]. The reliability of the CRR (ICC2,1 = 0.58–0.81) and the DTE in walking time (ICC2,1 = 0.11–0.80) was more varied. The reliability of the DTE in CRR (ICC2,1 = -0.31–0.40) was poor to fair. The walking time and CRR obtained in various dual-task walking tests were moderately to strongly correlated with those of the dual-task Timed-up-and-Go test, thus demonstrating good concurrent validity. None of the tests could discriminate fallers (those who had sustained at least one fall in the past year) from non-fallers. Limitation The results are generalizable to community-dwelling individuals with chronic stroke only. Conclusions The walking time derived from the various dual-task assessments generally demonstrated good to excellent reliability, making them potentially useful in clinical practice and future research endeavors. However, the usefulness of these measurements in predicting falls needs to be further explored. Relatively low reliability was shown in the cognitive outcomes and DTE, which may not be preferred measurements for assessing dual-task performance. PMID:26808662
Better Minds, Better Morals: A Procedural Guide to Better Judgment
Schaefer, G. Owen; Savulescu, Julian
2017-01-01
Making more moral decisions – an uncontroversial goal, if ever there was one. But how to go about it? In this article, we offer a practical guide on ways to promote good judgment in our personal and professional lives. We will do this not by outlining what the good life consists in or which values we should accept.Rather, we offer a theory of procedural reliability: a set of dimensions of thought that are generally conducive to good moral reasoning. At the end of the day, we all have to decide for ourselves what is good and bad, right and wrong. The best way to ensure we make the right choices is to ensure the procedures we’re employing are sound and reliable. We identify four broad categories of judgment to be targeted – cognitive, self-management, motivational and interpersonal. Specific factors within each category are further delineated, with a total of 14 factors to be discussed. For each, we will go through the reasons it generally leads to more morally reliable decision-making, how various thinkers have historically addressed the topic, and the insights of recent research that can offer new ways to promote good reasoning. The result is a wide-ranging survey that contains practical advice on how to make better choices. Finally, we relate this to the project of transhumanism and prudential decision-making. We argue that transhumans will employ better moral procedures like these. We also argue that the same virtues will enable us to take better control of our own lives, enhancing our responsibility and enabling us to lead better lives from the prudential perspective. PMID:29098205
2014-01-01
Objectives To evaluate the interobserver reliability of echocardiographic findings of right ventricle (RV) dysfunction for prognosticating normotensive patients with pulmonary embolism (PE). Methods A central panel of cardiologists evaluated echocardiographic studies of 75 patients included in the PROTECT study for the following signs: RV diameter, RV/left ventricular (LV) diameter ratio, hypokinesis of the RV free wall, and tricuspid plane systolic excursion (TAPSE). Investigators used intraclass correlation to assess agreement between the measurements of the central panel and each of the local cardiologists. Investigators used the single weighted kappa statistic to test for agreement between readers of interpretation of RV enlargement and RV hypokinesis. Results The two observers had fair agreement (k = 0.45) for RV enlargement assessed by the RV diameter, and good agreement (k = 0.65) for RV enlargement assessed by the RV/LV diameter ratio. The interobserver reliability of the assessment whether hypokinesis of the RV free wall is present was good (к = 0.70), and whether RV dysfunction (assessed by TAPSE measurement) is present was very good (k = 0.86). The intraclass correlation for the RV/LV diameter ratio was fair (0.55; 95% confidence interval [CI], 0.37-0.69), for the RV diameter was good (0.70; 95% CI, 0.56-0.80), and for the TAPSE measurement was very good (0.85; 95% CI, 0.77-0.90). On Bland-Altman analysis, the mean differences for RV diameter, RV/LV diameter ratio and TAPSE measurement were 2.33 (±5.38), 0.06 (±0.23) and 0.08 (±2.20), respectively. Conclusion TAPSE measurement is the least user dependent and most reproducible echocardiographic finding of RV dysfunction in normotensive patients with PE. PMID:25092465
Monthly fluctuations of insomnia symptoms in a population-based sample.
Morin, Charles M; Leblanc, M; Ivers, H; Bélanger, L; Mérette, Chantal; Savard, Josée; Jarrin, Denise C
2014-02-01
To document the monthly changes in sleep/insomnia status over a 12-month period; to determine the optimal time intervals to reliably capture new incident cases and recurrent episodes of insomnia and the likelihood of its persistence over time. Participants were 100 adults (mean age = 49.9 years; 66% women) randomly selected from a larger population-based sample enrolled in a longitudinal study of the natural history of insomnia. They completed 12 monthly telephone interviews assessing insomnia, use of sleep aids, stressful life events, and physical and mental health problems in the previous month. A total of 1,125 interviews of a potential 1,200 were completed. Based on data collected at each assessment, participants were classified into one of three subgroups: good sleepers, insomnia symptoms, and insomnia syndrome. At baseline, 42 participants were classified as good sleepers, 34 met criteria for insomnia symptoms, and 24 for an insomnia syndrome. There were significant fluctuations of insomnia over time, with 66% of the participants changing sleep status at least once over the 12 monthly assessments (51.5% for good sleepers, 59.5% for insomnia syndrome, and 93.4% for insomnia symptoms). Changes of status were more frequent among individuals with insomnia symptoms at baseline (mean = 3.46, SD = 2.36) than among those initially classified as good sleepers (mean = 2.12, SD = 2.70). Among the subgroup with insomnia symptoms at baseline, 88.3% reported improved sleep (i.e., became good sleepers) at least once over the 12 monthly assessments compared to 27.7% whose sleep worsened (i.e., met criteria for an insomnia syndrome) during the same period. Among individuals classified as good sleepers at baseline, risks of developing insomnia symptoms and syndrome over the subsequent months were, respectively, 48.6% and 14.5%. Monthly assessment over an interval of 6 months was found most reliable to estimate incidence rates, while an interval of 3 months proved the most reliable for defining chronic insomnia. Monthly assessment of insomnia and sleep patterns revealed significant variability over the course of a 12-month period. These findings highlight the importance for future epidemiological studies of conducting repeated assessment at shorter than the typical yearly interval in order to reliably capture the natural course of insomnia over time.
Code of Federal Regulations, 2014 CFR
2014-07-01
... educational, medical, retirement, social welfare, or other such benefits from a foreign country; (4) Residence... recur and does not cast doubt on the individual's current reliability, trustworthiness, or good judgment..., good-faith efforts to correct the omission, concealment, or falsification before being confronted with...
Code of Federal Regulations, 2010 CFR
2010-07-01
... educational, medical, retirement, social welfare, or other such benefits from a foreign country; (4) Residence... recur and does not cast doubt on the individual's current reliability, trustworthiness, or good judgment..., good-faith efforts to correct the omission, concealment, or falsification before being confronted with...
Code of Federal Regulations, 2012 CFR
2012-07-01
... educational, medical, retirement, social welfare, or other such benefits from a foreign country; (4) Residence... recur and does not cast doubt on the individual's current reliability, trustworthiness, or good judgment..., good-faith efforts to correct the omission, concealment, or falsification before being confronted with...
Code of Federal Regulations, 2013 CFR
2013-07-01
... educational, medical, retirement, social welfare, or other such benefits from a foreign country; (4) Residence... recur and does not cast doubt on the individual's current reliability, trustworthiness, or good judgment..., good-faith efforts to correct the omission, concealment, or falsification before being confronted with...
Code of Federal Regulations, 2011 CFR
2011-07-01
... educational, medical, retirement, social welfare, or other such benefits from a foreign country; (4) Residence... recur and does not cast doubt on the individual's current reliability, trustworthiness, or good judgment..., good-faith efforts to correct the omission, concealment, or falsification before being confronted with...
Song, Xingju; Yan, Min; Hu, Dandan; Wang, Yu; Wang, Ning; Gu, Xiaobin; Peng, Xuerong; Yang, Guangyou
2016-08-17
The larval stage of Echinococcus granulosus is the etiological agent of cystic echinococcosis (CE), which causes serious morbidity and mortality in many areas. There is no reliable method to monitor sheep CE. Here, we characterize E. granulosus glutaredoxin 1 (Eg-Grx1) and report an improved immunodiagnostic method for CE. We cloned and expressed recombinant Eg-Grx1 and generated antibodies. We analyzed the location of the protein in different parasite stages by fluorescence immunohistochemistry, detected the immunogenicity of recombinant Eg-Grx1, and developed an indirect ELISA (iELISA) for CE serodiagnosis. Eg-Grx1 is a classic dithiol Grx with several GSH-binding motifs. Native Eg-Grx1 protein was distributed in the tegument of protoscoleces, the whole germinal layer, and the parenchymatous tissue of adult worms. Recombinant Eg-Grx1 exhibited good immunoreactivity to CE-infected sheep serum. An iELISA using this antigen showed specificity of 64.3 % (9/14) and sensitivity of 1:3200, and the diagnostic accordance rate was 97.9 % (47/48) compared with the results of necropsy. We characterized a novel Grx (Eg-Grx1) from a parasitic helminth and present a comprehensive analysis of the sequence and structure of this protein. The recombinant Eg-Grx1 protein showed good potential serodiagnostic performance, and we established an iELISA method, which may contribute to the surveillance of sheep CE in epidemic areas.
Zou, Bin; Guo, Yunlong; Shen, Nannan; Xiao, Anshan; Li, Mingjun; Zhu, Liang; Wan, Pengbo; Sun, Xiaoming
2017-12-19
Ultrasensitive room temperature real-time NO₂ sensors are highly desirable due to potential threats on environmental security and personal respiratory. Traditional NO₂ gas sensors with highly operated temperatures (200-600 °C) and limited reversibility are mainly constructed from semiconducting oxide-deposited ceramic tubes or inter-finger probes. Herein, we report the functionalized graphene network film sensors assembled on an electrospun three-dimensional (3D) nanonetwork skeleton for ultrasensitive NO₂ sensing. The functional 3D scaffold was prepared by electrospinning interconnected polyacrylonitrile (PAN) nanofibers onto a nylon window screen to provide a 3D nanonetwork skeleton. Then, the sulfophenyl-functionalized reduced graphene oxide (SFRGO) was assembled on the electrospun 3D nanonetwork skeleton to form SFRGO network films. The assembled functionalized graphene network film sensors exhibit excellent NO₂ sensing performance (10 ppb to 20 ppm) at room temperature, reliable reversibility, good selectivity, and better sensing cycle stability. These improvements can be ascribed to the functionalization of graphene with electron-withdrawing sulfophenyl groups, the high surface-to-volume ratio, and the effective sensing channels from SFRGO wrapping onto the interconnected 3D scaffold. The SFRGO network-sensing film has the advantages of simple preparation, low cost, good processability, and ultrasensitive NO₂ sensing, all advantages that can be utilized for potential integration into smart windows and wearable electronic devices for real-time household gas sensors.
NASA Astrophysics Data System (ADS)
Matinise, N.; Kaviyarasu, K.; Mongwaketsi, N.; Khamlich, S.; Kotsedi, L.; Mayedwa, N.; Maaza, M.
2018-07-01
The main motivation of the research study involves development of reliable, accurate, inexpensive and environmental friendly method for the synthesis of zinc ferrite (ZnFe2O4) nanocomposites. It was thought of interest to synthesized zinc ferrite via green synthetic method using Moringa Oleifera extract. For the first time, we used green synthetic route via Moringa Oleifera extract acted as both chelating and reducing agents to synthesis spinel ZnFe2O4 nanocomposites. The physical and electrochemical properties were characterized using different techniques such as High Resolve Transmission Electron Microscope (HRTEM) Energy Dispersive X-ray Spectroscopy (EDS) X-ray diffraction (XRD) Fourier transform-infrared (FT-IR) Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The XRD pattern thus clearly illustrated that the ZnFe2O4 nanocmposites synthesized by the green method were good crystalline in nature. The time constant and exchange current of ZnFe2O4 nanocomposites from EIS analysis were calculated and found to be 5.2001 × 10-4 s/rad and 6.59432 × 10-4 A, respectively. Based on the electrochemical results, GCE/ZnFe2O4 electrode exhibited a good voltametric response, high electro-activity, and excellent electrochemical performance making it a highly suitable/promising electrode for electrochemical applications.
An FMRI-compatible Symbol Search task.
Liebel, Spencer W; Clark, Uraina S; Xu, Xiaomeng; Riskin-Jones, Hannah H; Hawkshead, Brittany E; Schwarz, Nicolette F; Labbe, Donald; Jerskey, Beth A; Sweet, Lawrence H
2015-03-01
Our objective was to determine whether a Symbol Search paradigm developed for functional magnetic resonance imaging (FMRI) is a reliable and valid measure of cognitive processing speed (CPS) in healthy older adults. As all older adults are expected to experience cognitive declines due to aging, and CPS is one of the domains most affected by age, establishing a reliable and valid measure of CPS that can be administered inside an MR scanner may prove invaluable in future clinical and research settings. We evaluated the reliability and construct validity of a newly developed FMRI Symbol Search task by comparing participants' performance in and outside of the scanner and to the widely used and standardized Symbol Search subtest of the Wechsler Adult Intelligence Scale (WAIS). A brief battery of neuropsychological measures was also administered to assess the convergent and discriminant validity of the FMRI Symbol Search task. The FMRI Symbol Search task demonstrated high test-retest reliability when compared to performance on the same task administered out of the scanner (r=.791; p<.001). The criterion validity of the new task was supported, as it exhibited a strong positive correlation with the WAIS Symbol Search (r=.717; p<.001). Predicted convergent and discriminant validity patterns of the FMRI Symbol Search task were also observed. The FMRI Symbol Search task is a reliable and valid measure of CPS in healthy older adults and exhibits expected sensitivity to the effects of age on CPS performance.
Haugan, Gørill; Drageset, Jorunn
2014-08-01
Depression and anxiety are particularly common among individuals living in long-term care facilities. Therefore, access to a valid and reliable measure of anxiety and depression among nursing home patients is highly warranted. To investigate the dimensionality, reliability and construct validity of the Hospital Anxiety and Depression scale (HADS) in a cognitively intact nursing home population. Cross-sectional data were collected from two samples; 429 cognitively intact nursing home patients participated, representing 74 different Norwegian nursing homes. Confirmative factor analyses and correlations with selected constructs were used. The two-factor model provided a good fit in Sample1, revealing a poorer fit in Sample2. Good-acceptable measurement reliability was demonstrated, and construct validity was supported. Using listwise deletion the sample sizes were 227 and 187, for Sample1 and Sample2, respectively. Greater sample sizes would have strengthen the statistical power in the tests. The researchers visited the participants to help fill in the questionnaires; this might have introduced some bias into the respondents׳ reporting. The 14 HADS items were part of greater questionnaires. Thus, frail, older NH patients might have tired during the interview causing a possible bias. Low reliability for depression was disclosed, mainly resulting from three items appearing to be inappropriate indicators for depression in this population. Further research is needed exploring which items might perform as more reliably indicators for depression among nursing home patients. Copyright © 2014 Elsevier B.V. All rights reserved.
Reliability of conditioned pain modulation: a systematic review
Kennedy, Donna L.; Kemp, Harriet I.; Ridout, Deborah; Yarnitsky, David; Rice, Andrew S.C.
2016-01-01
Abstract A systematic literature review was undertaken to determine if conditioned pain modulation (CPM) is reliable. Longitudinal, English language observational studies of the repeatability of a CPM test paradigm in adult humans were included. Two independent reviewers assessed the risk of bias in 6 domains; study participation; study attrition; prognostic factor measurement; outcome measurement; confounding and analysis using the Quality in Prognosis Studies (QUIPS) critical assessment tool. Intraclass correlation coefficients (ICCs) less than 0.4 were considered to be poor; 0.4 and 0.59 to be fair; 0.6 and 0.75 good and greater than 0.75 excellent. Ten studies were included in the final review. Meta-analysis was not appropriate because of differences between studies. The intersession reliability of the CPM effect was investigated in 8 studies and reported as good (ICC = 0.6-0.75) in 3 studies and excellent (ICC > 0.75) in subgroups in 2 of those 3. The assessment of risk of bias demonstrated that reporting is not comprehensive for the description of sample demographics, recruitment strategy, and study attrition. The absence of blinding, a lack of control for confounding factors, and lack of standardisation in statistical analysis are common. Conditioned pain modulation is a reliable measure; however, the degree of reliability is heavily dependent on stimulation parameters and study methodology and this warrants consideration for investigators. The validation of CPM as a robust prognostic factor in experimental and clinical pain studies may be facilitated by improvements in the reporting of CPM reliability studies. PMID:27559835
Myer, Gregory D; Wordeman, Samuel C; Sugimoto, Dai; Bates, Nathaniel A; Roewer, Benjamin D; Medina McKeon, Jennifer M; DiCesare, Christopher A; Di Stasi, Stephanie L; Barber Foss, Kim D; Thomas, Staci M; Hewett, Timothy E
2014-05-01
Multi-center collaborations provide a powerful alternative to overcome the inherent limitations to single-center investigations. Specifically, multi-center projects can support large-scale prospective, longitudinal studies that investigate relatively uncommon outcomes, such as anterior cruciate ligament injury. This project was conceived to assess within- and between-center reliability of an affordable, clinical nomogram utilizing two-dimensional video methods to screen for risk of knee injury. The authors hypothesized that the two-dimensional screening methods would provide good-to-excellent reliability within and between institutions for assessment of frontal and sagittal plane biomechanics. Nineteen female, high school athletes participated. Two-dimensional video kinematics of the lower extremity during a drop vertical jump task were collected on all 19 study participants at each of the three facilities. Within-center and between-center reliability were assessed with intra- and inter-class correlation coefficients. Within-center reliability of the clinical nomogram variables was consistently excellent, but between-center reliability was fair-to-good. Within-center intra-class correlation coefficient for all nomogram variables combined was 0.98, while combined between-center inter-class correlation coefficient was 0.63. Injury risk screening protocols were reliable within and repeatable between centers. These results demonstrate the feasibility of multi-site biomechanical studies and establish a framework for further dissemination of injury risk screening algorithms. Specifically, multi-center studies may allow for further validation and optimization of two-dimensional video screening tools. 2b.
Inter-operator and inter-device agreement and reliability of the SEM Scanner.
Clendenin, Marta; Jaradeh, Kindah; Shamirian, Anasheh; Rhodes, Shannon L
2015-02-01
The SEM Scanner is a medical device designed for use by healthcare providers as part of pressure ulcer prevention programs. The objective of this study was to evaluate the inter-rater and inter-device agreement and reliability of the SEM Scanner. Thirty-one (31) volunteers free of pressure ulcers or broken skin at the sternum, sacrum, and heels were assessed with the SEM Scanner. Each of three operators utilized each of three devices to collect readings from four anatomical sites (sternum, sacrum, left and right heels) on each subject for a total of 108 readings per subject collected over approximately 30 min. For each combination of operator-device-anatomical site, three SEM readings were collected. Inter-operator and inter-device agreement and reliability were estimated. Over the course of this study, more than 3000 SEM Scanner readings were collected. Agreement between operators was good with mean differences ranging from -0.01 to 0.11. Inter-operator and inter-device reliability exceeded 0.80 at all anatomical sites assessed. The results of this study demonstrate the high reliability and good agreement of the SEM Scanner across different operators and different devices. Given the limitations of current methods to prevent and detect pressure ulcers, the SEM Scanner shows promise as an objective, reliable tool for assessing the presence or absence of pressure-induced tissue damage such as pressure ulcers. Copyright © 2015 Bruin Biometrics, LLC. Published by Elsevier Ltd.. All rights reserved.
Measuring competence in endoscopic sinus surgery.
Syme-Grant, J; White, P S; McAleer, J P G
2008-02-01
Competence based education is currently being introduced into higher surgical training in the UK. Valid and reliable performance assessment tools are essential to ensure competencies are achieved. No such tools have yet been reported in the UK literature. We sought to develop and pilot test an Endoscopic Sinus Surgery Competence Assessment Tool (ESSCAT). The ESSCAT was designed for in-theatre assessment of higher surgical trainees in the UK. The ESSCAT rating matrix was developed through task analysis of ESS procedures. All otolaryngology consultants and specialist registrars in Scotland were given the opportunity to contribute to its refinement. Two cycles of in-theatre testing were used to ensure utility and gather quantitative data on validity and reliability. Videos of trainees performing surgery were used in establishing inter-rater reliability. National consultation, the consensus derived minimum standard of performance, Cronbach's alpha = 0.89 and demonstration of trainee learning (p = 0.027) during the in vivo application of the ESSCAT suggest a high level of validity. Inter-rater reliability was moderate for competence decisions (Cohen's Kappa = 0.5) and good for total scores (Intra-Class Correlation Co-efficient = 0.63). Intra-rater reliability was good for both competence decisions (Kappa = 0.67) and total scores (Kendall's Tau-b = 0.73). The ESSCAT generates a valid and reliable assessment of trainees' in-theatre performance of endoscopic sinus surgery. In conjunction with ongoing evaluation of the instrument we recommend the use of the ESSCAT in higher specialist training in otolaryngology in the UK.
Iversen, J V; Bartels, E M; Jørgensen, J E; Nielsen, T G; Ginnerup, C; Lind, M C; Langberg, H
2016-12-01
The VISA-A questionnaire has proven to be a valid and reliable tool for assessing severity of Achilles tendinopathy (AT). The aim was to translate and cross-culturally adapt the VISA-A questionnaire for a Danish-speaking AT population, and subsequently perform validity and reliability tests. Translation and following cross-cultural adaptation was performed as translation, synthesis, reverse translation, expert review, and pretesting. The final Danish version (VISA-A-DK) was tested for reliability on healthy controls (n = 75) and patients (n = 36). Tests for internal consistency, validity, and structure were performed on 71 patients. VISA-A-DK showed good reliability for patients (r = 0.80 ICC = 0.79) and healthy individuals (r = 0.98 ICC = 0.97). Internal consistency was 0.73 (Cronbach's alpha). The mean VISA-A-DK score in AT patients was 51 [47-55]. This was significantly lower than healthy controls with a score of 93 (90-95). Criterion validity was considered good when comparing the scores of the Danish version with the original version in both healthy individuals and patients. VISA-A-DK is a valid and reliable instrument and has shown compatible to the original version in assessment of AT patients. VISA-A-DK is a useful tool in the assessment of AT, both in research and in a clinical setting. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Study of Fuze Structure and Reliability Design Based on the Direct Search Method
NASA Astrophysics Data System (ADS)
Lin, Zhang; Ning, Wang
2017-03-01
Redundant design is one of the important methods to improve the reliability of the system, but mutual coupling of multiple factors is often involved in the design. In my study, Direct Search Method is introduced into the optimum redundancy configuration for design optimization, in which, the reliability, cost, structural weight and other factors can be taken into account simultaneously, and the redundant allocation and reliability design of aircraft critical system are computed. The results show that this method is convenient and workable, and applicable to the redundancy configurations and optimization of various designs upon appropriate modifications. And this method has a good practical value.
Muehrer, Rebecca J; Lanuza, Dorothy M; Brown, Roger L; Djamali, Arjang
2015-01-01
This study describes the development and psychometric testing of the Sexual Concerns Questionnaire (SCQ) in kidney transplant (KTx) recipients. Construct validity was assessed using the Kroonenberg and Lewis exploratory/confirmatory procedure and testing hypothesized relationships with established questionnaires. Configural and weak invariance were examined across gender, dialysis history, relationship status, and transplant type. Reliability was assessed with Cronbach's alpha, composite reliability, and test-retest reliability. Factor analysis resulted in a 7-factor solution and suggests good model fit. Construct validity was also supported by the tests of hypothesized relationships. Configural and weak invariance were supported for all subgroups. Reliability of the SCQ was also supported. Findings indicate the SCQ is a valid and reliable measure of KTx recipients' sexual concerns.
Zumpano, Camila Eugênia; Mendonça, Tânia Maria da Silva; Silva, Carlos Henrique Martins da; Correia, Helena; Arnold, Benjamin; Pinto, Rogério de Melo Costa
2017-01-23
This study aimed to perform the cross-cultural adaptation and validation of the Patient-Reported Outcomes Measurement Information System (PROMIS) Global Health scale in the Portuguese language. The ten Global Health items were cross-culturally adapted by the method proposed in the Functional Assessment of Chronic Illness Therapy (FACIT). The instrument's final version in Portuguese was self-administered by 1,010 participants in Brazil. The scale's precision was verified by floor and ceiling effects analysis, reliability of internal consistency, and test-retest reliability. Exploratory and confirmatory factor analyses were used to assess the construct's validity and instrument's dimensionality. Calibration of the items used the Gradual Response Model proposed by Samejima. Four global items required adjustments after the pretest. Analysis of the psychometric properties showed that the Global Health scale has good reliability, with Cronbach's alpha of 0.83 and intra-class correlation of 0.89. Exploratory and confirmatory factor analyses showed good fit in the previously established two-dimensional model. The Global Physical Health and Global Mental Health scale showed good latent trait coverage according to the Gradual Response Model. The PROMIS Global Health items showed equivalence in Portuguese compared to the original version and satisfactory psychometric properties for application in clinical practice and research in the Brazilian population.
A semi-automated algorithm for hypothalamus volumetry in 3 Tesla magnetic resonance images.
Wolff, Julia; Schindler, Stephanie; Lucas, Christian; Binninger, Anne-Sophie; Weinrich, Luise; Schreiber, Jan; Hegerl, Ulrich; Möller, Harald E; Leitzke, Marco; Geyer, Stefan; Schönknecht, Peter
2018-07-30
The hypothalamus, a small diencephalic gray matter structure, is part of the limbic system. Volumetric changes of this structure occur in psychiatric diseases, therefore there is increasing interest in precise volumetry. Based on our detailed volumetry algorithm for 7 Tesla magnetic resonance imaging (MRI), we developed a method for 3 Tesla MRI, adopting anatomical landmarks and work in triplanar view. We overlaid T1-weighted MR images with gray matter-tissue probability maps to combine anatomical information with tissue class segmentation. Then, we outlined regions of interest (ROIs) that covered potential hypothalamus voxels. Within these ROIs, seed growing technique helped define the hypothalamic volume using gray matter probabilities from the tissue probability maps. This yielded a semi-automated method with short processing times of 20-40 min per hypothalamus. In the MRIs of ten subjects, reliabilities were determined as intraclass correlations (ICC) and volume overlaps in percent. Three raters achieved very good intra-rater reliabilities (ICC 0.82-0.97) and good inter-rater reliabilities (ICC 0.78 and 0.82). Overlaps of intra- and inter-rater runs were very good (≥ 89.7%). We present a fast, semi-automated method for in vivo hypothalamus volumetry in 3 Tesla MRI. Copyright © 2018 Elsevier B.V. All rights reserved.
Atilola, Olayinka; Stevanović, Dejan
2014-04-01
Quality of life (QOL) is a universally accepted concept for measuring the impact of different aspects of life on general well-being. Adaptation of existing QOL instruments to local cultures has been identified as a better strategy than development of new ones. To translate and adapt the Paediatric Quality of Life Inventory™ Version 4.0 Generic Core Scales (PedsQL™) to the Yoruba language and culture and to test the psychometric properties of the adapted instrument among adolescents. Psychometric properties including internal consistency reliability, construct and factorial validity of the Yoruba version of PedsQL™ were evaluated using standard procedures. The self report and proxy scales of the Yoruba PedsQL™ were developed with good cultural relevance and semantic/conceptual equivalence. Results from 527 adolescents revealed a Cronbach's coefficient which exceeded 0.7 for internal consistency reliability for all scores. The healthy subjects reported higher PedsQL™ scores than those with mental health and physical problems, which confirmed construct validity. Confirmatory factor analysis revealed a good model fit for the Psychosocial Health score, but not for the other measures. The Yoruba PedsQL™ is culturally appropriate and with good internal consistency, reliability and construct validity. More work is needed regarding its factorial validity.
A Multi-Domain Self-Report Measure of Coparenting
Feinberg, Mark E.; Brown, Louis D.; Kan, Marni L.
2012-01-01
SYNOPSIS Objective This study reports the psychometric properties of a multi-domain measure of the coparenting relationship in dual-parent families. Method 152 couples participating in a transition to parenthood study completed the Coparenting Relationship Scale and additional measures during home visits at child age 6 months, 1 year, and 3 years. Results Psychometric and construct validity assessments indicated the measure performed satisfactorily. The 35-item measure demonstrated good reliability and strong stability. Subscales measuring theoretically and empirically important aspects of coparenting (coparenting agreement, coparenting closeness, exposure of child to conflict, coparenting support, coparenting undermining, endorsement of partner’s parenting, and division of labor) demonstrated good reliability as well. A 14-item brief overall measure showed very strong associations with the overall measure. Relations of the full scale with a measure of social desirability were weak, and the full scale was positively associated with positive dimensions of the dyadic couple relationship (love, sex/romance, couple efficacy) and inversely associated with negative dimensions (conflict, ineffective arguing)—as expected. Conclusions This initial examination of the Coparenting Relationship Scale suggests that it possesses good psychometric properties (reliability, stability, construct validity, and inter-rater agreement), can be flexibly administered in short and long forms, and is positioned to promote further conceptual and methodological progress in the study of coparenting. PMID:23166477
George L. Peterson; Thomas C. Brown
1998-01-01
The paired comparison (PC) method is used to investigate reliability, transitivity, and decision time for binary choices among goods and sums of money. The PC method reveals inconsistent choices and yields individual preference order over the set of items being compared. The data reported support the transitivity assumption and demonstrate high reliability for...
ERIC Educational Resources Information Center
Rogers, Daniel T.
2015-01-01
This study further examined the reliability and validity of the Learning Alliance Inventory (LAI), a self-report measure designed to assess the working alliance between a student and a teacher. The LAI was found to have good internal consistency and test--retest reliability, and it demonstrated the predicted convergence with measures of immediacy…
Glaister, Mark; Stone, Michael H; Stewart, Andrew M; Hughes, Michael; Moir, Gavin L
2004-08-01
The purpose of the present study was to assess the reliability and validity of fatigue measures, as derived from 4 separate formulae, during tests of repeat sprint ability. On separate days over a 3-week period, 2 groups of 7 recreationally active men completed 6 trials of 1 of 2 maximal (20 x 5 seconds) intermittent cycling tests with contrasting recovery periods (10 or 30 seconds). All trials were conducted on a friction-braked cycle ergometer, and fatigue scores were derived from measures of mean power output for each sprint. Apart from formula 1, which calculated fatigue from the percentage difference in mean power output between the first and last sprint, all remaining formulae produced fatigue scores that showed a reasonably good level of test-retest reliability in both intermittent test protocols (intraclass correlation range: 0.78-0.86; 95% likely range of true values: 0.54-0.97). Although between-protocol differences in the magnitude of the fatigue scores suggested good construct validity, within-protocol differences highlighted limitations with each formula. Overall, the results support the use of the percentage decrement score as the most valid and reliable measure of fatigue during brief maximal intermittent work.
Gorlin, Eugenia I; Dalrymple, Kristy; Chelminski, Iwona; Zimmerman, Mark
2016-08-30
Despite growing recognition that the symptoms and functional impairments of Attention Deficit/Hyperactivity Disorder (ADHD) persist into adulthood, only a few psychometrically sound diagnostic measures have been developed for the assessment of ADHD in adults, and none have been validated for use in a broad treatment-seeking psychiatric sample. The current study presents the reliability and validity of a semi-structured DSM-based diagnostic interview module for ADHD, which was administered to 1194 adults presenting to an outpatient psychiatric practice. The module showed excellent internal consistency and interrater reliability, good convergent and discriminant validity (as indexed by relatively high correlations with self-report measures of ADHD and ADHD-related constructs and little or no correlation with other, non-ADHD symptom domains), and good construct validity (as indexed by significantly higher rates of psychosocial impairment and self-reported family history of ADHD in individuals who meet criteria for an ADHD diagnosis). This instrument is thus a reliable and valid diagnostic tool for the detection of ADHD in adults presenting for psychiatric evaluation and treatment. Published by Elsevier Ireland Ltd.
Clinical applications of correlational vestibular autorotation test.
Hsieh, Li-Chun; Lin, Te-Ming; Chang, Yu-Min; Kuo, Terry B J; Lee, Gho-She
2015-06-01
The correlational vestibular autorotation test (VAT) system has the advantages of good test-retest reliability and calibrations of absolute degrees of eye movement are unnecessary when acquiring a cross correlation coefficient (CCC). The approach is able to efficiently detect peripheral vestibulopathies. A VAT has some drawbacks including poor test-retest reliability and slippage of sensor. This study aimed to develop a correlational VAT system and to evaluate the reliability and applicability of this system. Twenty healthy participants and 10 vertiginous patients were enrolled. Vertical and horizontal autorotations from 0 to 3 Hz with either closed or open eyes were performed. A small sensor and a wireless transmission technique were used to acquire the electro-ocular graph and head velocity signals. The two signals were analyzed using CCCs to assess the functioning of the vestibular ocular reflex (VOR). The results showed a significantly greater CCC for open-eye versus closed-eye of head autorotations. The CCCs also increased significantly with head rotational frequencies. Moreover, the CCCs significantly correlated with the VOR gains at autorotation frequencies ≥1.0 Hz. The test-retest reliability was good (intraclass correlation coefficients ≥0.85). The vertiginous participants had significantly lower individual CCCs and overall average CCC than age- and-gender matched controls.
Johansson, M; Carlberg, E B; Jylli, L
2010-06-01
To test the validity and reliability of a Swedish version of the Non-Communicating Children's Pain Checklist-Postoperative Version (NCCPC-PV). Thirty-two consecutive children/adolescents (2-20 years of age) with cognitive impairment and no verbal communication from four habilitation centres were admitted to the study. Each child's behaviour was observed by a parent or a caregiver and by a physiotherapist in two calm and two painful situations within the child's everyday life. The raters independently assessed and graded the child's behaviour during 5 min according to the translated Swedish version of the NCCPC-PV. The intrarater and interrater reliability were determined, and the construct validity was examined. The results from 202 assessments showed that the construct validity was good: children's behavioural signs differed significantly between situations of pain and situations of calm (p < 0.001). Repeated assessments showed poor agreement both within and between raters [intraclass correlation coefficient (ICC) 0.51-0.65]. The agreement for pain was good (ICC 0.83). The Swedish version of the NCCPC-PV can be used for pain assessment in children with cognitive impairments who lack verbal communication. Aspects of reliability need to be further analysed.
A comprehensive approach for diagnosing opportunities for improving the performance of a WWTP.
Silva, C; Matos, J Saldanha; Rosa, M J
2016-12-01
High quality services of wastewater treatment require a continuous assessment and improvement of the technical, environmental and economic performance. This paper demonstrates a comprehensive approach for benchmarking wastewater treatment plants (WWTPs), using performance indicators (PIs) and indices (PXs), in a 'plan-do-check-act' cycle routine driven by objectives. The performance objectives herein illustrated were to diagnose the effectiveness and energy performance of an oxidation ditch WWTP. The PI and PX results demonstrated an effective and reliable oxidation ditch (good-excellent performance), and a non-reliable UV disinfection (unsatisfactory-excellent performance) related with influent transmittance and total suspended solids. The energy performance increased with the treated wastewater volume and was unsatisfactory below 50% of plant capacity utilization. The oxidation ditch aeration performed unsatisfactorily and represented 38% of the plant energy consumption. The results allowed diagnosing opportunities for improving the energy and economic performance considering the influent flows, temperature and concentrations, and for levering the WWTP performance to acceptable-good effectiveness, reliability and energy efficiency. Regarding the plant reliability for fecal coliforms, improvement of UV lamp maintenance and optimization of the UV dose applied and microscreen recommissioning were suggested.
The Arabic version of the Mayo-Portland Adaptability Inventory 4: a validation study.
Hamed, Razan; Tariah, Hashem Abu; Malkawi, Somaya; Holm, Margo B
2012-09-01
The Mayo-Portland Adaptability Inventory 4 (MPAI-4) is a valid and reliable assessment tool to detect clinical impairments in patients with acquired brain injury. The tool is widely used by rehabilitation therapists worldwide, given its good psychometric properties and its availability in several languages. The purpose of this study was to translate the tool into Arabic and to examine its validity and reliability with multiple sclerosis and stroke patients. A total of 128 participants were enrolled in this study: 49 with multiple sclerosis, 17 with stroke, and 62 healthy adults. The psychometric properties of discriminative and convergent construct validity as well as test-retest reliability were tested. The translated tool, the Arabic-MPAI-4 (A-MPAI-4), significantly discriminated among the three subgroups (F=50.93, P<0.001), correlated moderately but significantly with the Arabic version of the Performance Assessment of Self-Care Skills Self-Report as a measure of functional independence in daily activities (r=-0.35, P<0.001), and showed good stability over time (r=0.73, P<0.001). The A-MPAI-4 is a valid and reliable tool for clinical use with multiple sclerosis and stroke patients who speak Arabic.
Bandwidth efficient coding for satellite communications
NASA Technical Reports Server (NTRS)
Lin, Shu; Costello, Daniel J., Jr.; Miller, Warner H.; Morakis, James C.; Poland, William B., Jr.
1992-01-01
An error control coding scheme was devised to achieve large coding gain and high reliability by using coded modulation with reduced decoding complexity. To achieve a 3 to 5 dB coding gain and moderate reliability, the decoding complexity is quite modest. In fact, to achieve a 3 dB coding gain, the decoding complexity is quite simple, no matter whether trellis coded modulation or block coded modulation is used. However, to achieve coding gains exceeding 5 dB, the decoding complexity increases drastically, and the implementation of the decoder becomes very expensive and unpractical. The use is proposed of coded modulation in conjunction with concatenated (or cascaded) coding. A good short bandwidth efficient modulation code is used as the inner code and relatively powerful Reed-Solomon code is used as the outer code. With properly chosen inner and outer codes, a concatenated coded modulation scheme not only can achieve large coding gains and high reliability with good bandwidth efficiency but also can be practically implemented. This combination of coded modulation and concatenated coding really offers a way of achieving the best of three worlds, reliability and coding gain, bandwidth efficiency, and decoding complexity.
Fan, Ching-Lin; Shang, Ming-Chi; Li, Bo-Jyun; Lin, Yu-Zuo; Wang, Shea-Jue; Lee, Win-Der; Hung, Bohr-Ran
2015-01-01
This study proposes a two-photomask process for fabricating amorphous indium–gallium–zinc oxide (a-IGZO) thin-film transistors (TFTs) that exhibit a self-aligned structure. The fabricated TFTs, which lack etching-stop (ES) layers, have undamaged a-IGZO active layers that facilitate superior performance. In addition, we demonstrate a bilayer passivation method that uses a polytetrafluoroethylene (Teflon) and SiO2 combination layer for improving the electrical reliability of the fabricated TFTs. Teflon was deposited as a buffer layer through thermal evaporation. The Teflon layer exhibited favorable compatibility with the underlying IGZO channel layer and effectively protected the a-IGZO TFTs from plasma damage during SiO2 deposition, resulting in a negligible initial performance drop in the a-IGZO TFTs. Compared with passivation-free a-IGZO TFTs, passivated TFTs exhibited superior stability even after 168 h of aging under ambient air at 95% relative humidity. PMID:28788026